Sample records for balanced detection technique

  1. Single-pixel imaging using balanced detection and a digital micromirror device

    NASA Astrophysics Data System (ADS)

    Soldevila, F.; Clemente, P.; Tajahuerce, E.; Uribe-Patarroyo, Néstor; Andrés, P.; Lancis, J.

    2018-02-01

    Over the past decade, single-pixel imaging (SPI) has established as a viable tool in scenarios where traditional imaging techniques struggle to provide images with acceptable quality in practicable times and reasonable costs. However, SPI still has several limitations inherent to the technique, such as working with spurious light and in real time. Here we present a novel approach, using complementary measurements and a single balanced detector. By using balanced detection, we improve the frame rate of the complementary measurement architectures by a factor of two. Furthermore, the use of a balanced detector provides environmental light immunity to the method.

  2. 75 FR 4134 - Pipeline Safety: Leak Detection on Hazardous Liquid Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-26

    ... http://dms.dot.gov . General information about the PHMSA Office of Pipeline Safety (OPS) can be... of leak detection by tracking product movement is essential to an understanding of line balance... pipelines, the line balance technique for leak detection can often be performed with manual calculations...

  3. Minimizing Alteration of Posterior Tibial Slope During Opening Wedge High Tibial Osteotomy: a Protocol with Experimental Validation in Paired Cadaveric Knees

    PubMed Central

    Westermann, Robert W; DeBerardino, Thomas; Amendola, Annunziato

    2014-01-01

    Introduction The High Tibial Osteotomy (HTO) is a reliable procedure in addressing uni- compartmental arthritis with associated coronal deformities. With osteotomy of the proximal tibia, there is a risk of altering the tibial slope in the sagittal plane. Surgical techniques continue to evolve with trends towards procedure reproducibility and simplification. We evaluated a modification of the Arthrex iBalance technique in 18 paired cadaveric knees with the goals of maintaining sagittal slope, increasing procedure efficiency, and decreasing use of intraoperative fluoroscopy. Methods Nine paired cadaveric knees (18 legs) underwent iBalance medial opening wedge high tibial osteotomies. In each pair, the right knee underwent an HTO using the modified technique, while all left knees underwent the traditional technique. Independent observers evaluated postoperative factors including tibial slope, placement of hinge pin, and implant placement. Specimens were then dissected to evaluate for any gross muscle, nerve or vessel injury. Results Changes to posterior tibial slope were similar using each technique. The change in slope in traditional iBalance technique was -0.3° ±2.3° and change in tibial slope using the modified iBalance technique was -0.4° ±2.3° (p=0.29). Furthermore, we detected no differences in posterior tibial slope between preoperative and postoperative specimens (p=0.74 traditional, p=0.75 modified). No differences in implant placement were detected between traditional and modified techniques. (p=0.85). No intraoperative iatrogenic complications (i.e. lateral cortex fracture, blood vessel or nerve injury) were observed in either group after gross dissection. Discussion & Conclusions Alterations in posterior tibial slope are associated with HTOs. Both traditional and modified iBalance techniques appear reliable in coronal plane corrections without changing posterior tibial slope. The present modification of the Arthrex iBalance technique may increase the efficiency of the operation and decrease radiation exposure to patients without compromising implant placement or global knee alignment. PMID:25328454

  4. Mass balance for on-line alphakLa estimation in activated sludge oxidation ditch.

    PubMed

    Chatellier, P; Audic, J M

    2001-01-01

    The capacity of an aeration system to transfer oxygen to a given activated sludge oxidation ditch is characterised by the alphakLa parameter. This parameter is difficult to measure under normal plant working conditions. Usually this measurement involves off-gas techniques or static mass balance. Therefore an on-line technique has been developed and tested in order to evaluate alphakLa. This technique deduces alphakLa from a data analysis of low cost sensor measurement: two flow meters and one oxygen probe. It involves a dynamic mass balance applied to aeration cycles selected according to given criteria. This technique has been applied to a wastewater treatment plant during four years. Significant variations of the alphakLa values have been detected while the number of blowers changes. This technique has been applied to another plant during two months.

  5. Optical beat interference noise reduction in OFDMA optical access link using self-homodyne balanced detection

    NASA Astrophysics Data System (ADS)

    Jung, Sang-Min; Won, Yong-Yuk; Han, Sang-Kook

    2013-12-01

    A Novel technique for reducing the OBI noise in optical OFDMA-PON uplink is presented. OFDMA is a multipleaccess/ multiplexing scheme that can provide multiplexing operation of user data streams onto the downlink sub-channels and uplink multiple access by means of dividing OFDM subcarriers as sub-channels. The main issue of high-speed, single-wavelength upstream OFDMA-PON arises from optical beating interference noise. Because the sub-channels are allocated dynamically to multiple access users over same nominal wavelength, it generates the optical beating interference among upstream signals. In this paper, we proposed a novel scheme using self-homodyne balanced detection in the optical line terminal (OLT) to reduce OBI noise which is generated in the uplink transmission of OFDMA-PON system. When multiple OFDMA sub-channels over the same nominal wavelength are received at the same time in the proposed architecture, OBI noises can be removed using balanced detection. Using discrete multitone modulation (DMT) to generate real valued OFDM signals, the proposed technique is verified through experimental demonstration.

  6. Automatic patient-adaptive bleeding detection in a capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Jung, Yun Sub; Kim, Yong Ho; Lee, Dong Ha; Lee, Sang Ho; Song, Jeong Joo; Kim, Jong Hyo

    2009-02-01

    We present a method for patient-adaptive detection of bleeding region for a Capsule Endoscopy (CE) images. The CE system has 320x320 resolution and transmits 3 images per second to receiver during around 10-hour. We have developed a technique to detect the bleeding automatically utilizing color spectrum transformation (CST) method. However, because of irregular conditions like organ difference, patient difference and illumination condition, detection performance is not uniform. To solve this problem, the detection method in this paper include parameter compensation step which compensate irregular image condition using color balance index (CBI). We have investigated color balance through sequential 2 millions images. Based on this pre-experimental result, we defined ΔCBI to represent deviate of color balance compared with standard small bowel color balance. The ΔCBI feature value is extracted from each image and used in CST method as parameter compensation constant. After candidate pixels were detected using CST method, they were labeled and examined with a bleeding character. We tested our method with 4,800 images in 12 patient data set (9 abnormal, 3 normal). Our experimental results show the proposed method achieves (before patient adaptive method : 80.87% and 74.25%, after patient adaptive method : 94.87% and 96.12%) of sensitivity and specificity.

  7. Suppression of optical beat interference-noise in orthogonal frequency division multiple access-passive optical network link using self-homodyne balanced detection

    NASA Astrophysics Data System (ADS)

    Won, Yong-Yuk; Jung, Sang-Min; Han, Sang-Kook

    2014-08-01

    A new technique, which reduces optical beat interference (OBI) noise in orthogonal frequency division multiple access-passive optical network (OFDMA-PON) links, is proposed. A self-homodyne balanced detection, which uses a single laser for the optical line terminal (OLT) as well as for the optical network unit (ONU), reduces OBI noise and also improves the signal to noise ratio (SNR) of the discrete multi-tone (DMT) signal. The proposed scheme is verified by transmitting quadrature phase shift keying (QPSK)-modulated DMT signal over a 20-km single mode fiber. The optical signal to noise ratio (OSNR), that is required for BER of 10-5, is reduced by 2 dB in the balanced detection compared with a single channel due to the cancellation of OBI noise in conjunction with the local laser.

  8. Error field detection in DIII-D by magnetic steering of locked modes

    DOE PAGES

    Shiraki, Daisuke; La Haye, Robert J.; Logan, Nikolas C.; ...

    2014-02-20

    Optimal correction coil currents for the n = 1 intrinsic error field of the DIII-D tokamak are inferred by applying a rotating external magnetic perturbation to steer the phase of a saturated locked mode with poloidal/toroidal mode number m/n = 2/1. The error field is detected non-disruptively in a single discharge, based on the toroidal torque balance of the resonant surface, which is assumed to be dominated by the balance of resonant electromagnetic torques. This is equivalent to the island being locked at all times to the resonant 2/1 component of the total of the applied and intrinsic error fields,more » such that the deviation of the locked mode phase from the applied field phase depends on the existing error field. The optimal set of correction coil currents is determined to be those currents which best cancels the torque from the error field, based on fitting of the torque balance model. The toroidal electromagnetic torques are calculated from experimental data using a simplified approach incorporating realistic DIII-D geometry, and including the effect of the plasma response on island torque balance based on the ideal plasma response to external fields. This method of error field detection is demonstrated in DIII-D discharges, and the results are compared with those based on the onset of low-density locked modes in ohmic plasmas. Furthermore, this magnetic steering technique presents an efficient approach to error field detection and is a promising method for ITER, particularly during initial operation when the lack of auxiliary heating systems makes established techniques based on rotation or plasma amplification unsuitable.« less

  9. [HRV-Spectral analysis of Pain, by 3D Evaluation and by Balance Index in the Pain Rehabilitation Field].

    PubMed

    Goto, Yukio

    2015-07-01

    Pain signaling is achieved by electrical impulses in the body; however, some electrical abnormalities can cause pain in the body without generating any visible symptoms. This phenomenon is sensed by the brain and a signal that may affect cardiac rhythms is immediately transmitted to the heart. To evaluate heart rate variability (HRV), the balance correction between an increase and decrease of heart rate was recorded in real time. Using a special method for spectral-analysis of the HRV, techniques for analyzing the essence of pain were developed, namely, the 'Balance index' and the '3D spectrum evaluation method'. Using these techniques, an alpha wave-like factor or a beta wave-like reaction can be obtained, and the nature and strength of pain can be displayed as spectral zones, as in a rainbow. The balance reaction can be shown by analyzing data in the frequency band using a 1/f-like spectral-analysis method. Additionally, emotional reactions can be detected using a 'Balance index' that can demonstrate imbalance responding to the pain. The mental state of the subject can also be inferred because this technique is adapted from the 1/f fluctuation theory related to the best balanced 1/f-sound wave in nature that comforts the human mind, similar to music (artificial sound wave). In this study, the variety and intensity of pain were determined from the frequency band resulting from the 1/f-spectral analysis of HRV fluctuation. These techniques could explain several situations related to medication or anesthesia and can be helpful in preventative treatment and/or explaining the differences in the effectiveness of various techniques for the rehabilitation of chronic pain.

  10. Artificial neural network techniques to improve the ability of optical coherence tomography to detect optic neuritis.

    PubMed

    Garcia-Martin, Elena; Herrero, Raquel; Bambo, Maria P; Ara, Jose R; Martin, Jesus; Polo, Vicente; Larrosa, Jose M; Garcia-Feijoo, Julian; Pablo, Luis E

    2015-01-01

    To analyze the ability of Spectralis optical coherence tomography (OCT) to detect multiple sclerosis (MS) and to distinguish MS eyes with antecedent optic neuritis (ON). To analyze the capability of artificial neural network (ANN) techniques to improve the diagnostic precision. MS patients and controls were enrolled (n = 217). OCT was used to determine the 768 retinal nerve fiber layer thicknesses. Sensitivity and specificity were evaluated to test the ability of OCT to discriminate between MS and healthy eyes, and between MS with and without antecedent ON using ANN. Using ANN technique multilayer perceptrons, OCT could detect MS with a sensitivity of 89.3%, a specificity of 87.6%, and a diagnostic precision of 88.5%. Compared with the OCT-provided parameters, the ANN had a better sensitivity-specificity balance. ANN technique improves the capability of Spectralis OCT to detect MS disease and to distinguish MS eyes with or without antecedent ON.

  11. Development of a Pattern Recognition Methodology for Determining Operationally Optimal Heat Balance Instrumentation Calibration Schedules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurt Beran; John Christenson; Dragos Nica

    2002-12-15

    The goal of the project is to enable plant operators to detect with high sensitivity and reliability the onset of decalibration drifts in all of the instrumentation used as input to the reactor heat balance calculations. To achieve this objective, the collaborators developed and implemented at DBNPS an extension of the Multivariate State Estimation Technique (MSET) pattern recognition methodology pioneered by ANAL. The extension was implemented during the second phase of the project and fully achieved the project goal.

  12. Reliability of System Identification Techniques to Assess Standing Balance in Healthy Elderly

    PubMed Central

    Maier, Andrea B.; Aarts, Ronald G. K. M.; van Gerven, Joop M. A.; Arendzen, J. Hans; Schouten, Alfred C.; Meskers, Carel G. M.; van der Kooij, Herman

    2016-01-01

    Objectives System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system identification techniques. Methods In twelve healthy elderly balance tests were performed twice a day during three days. Body sway was measured during two minutes of standing with eyes closed and the Balance test Room (BalRoom) was used to apply four disturbances simultaneously: two sensory disturbances, to the proprioceptive and the visual system, and two mechanical disturbances applied at the leg and trunk segment. Using system identification techniques, sensitivity functions of the sensory disturbances and the neuromuscular controller were estimated. Based on the generalizability theory (G theory), systematic errors and sources of variability were assessed using linear mixed models and reliability was assessed by computing indexes of dependability (ID), standard error of measurement (SEM) and minimal detectable change (MDC). Results A systematic error was found between the first and second trial in the sensitivity functions. No systematic error was found in the neuromuscular controller and body sway. The reliability of 15 of 25 parameters and body sway were moderate to excellent when the results of two trials on three days were averaged. To reach an excellent reliability on one day in 7 out of 25 parameters, it was predicted that at least seven trials must be averaged. Conclusion This study shows that system identification techniques are a promising method to assess the underlying systems involved in standing balance in elderly. However, most of the parameters do not appear to be reliable unless a large number of trials are collected across multiple days. To reach an excellent reliability in one third of the parameters, a training session for participants is needed and at least seven trials of two minutes must be performed on one day. PMID:26953694

  13. The Clinical Relevance of Force Platform Measures in Multiple Sclerosis: A Review

    PubMed Central

    Prosperini, Luca; Pozzilli, Carlo

    2013-01-01

    Balance impairment and falls are frequent in patients with multiple sclerosis (PwMS), and they may occur even at the earliest stage of the disease and in minimally impaired patients. The introduction of computer-based force platform measures (i.e., static and dynamic posturography) has provided an objective and sensitive tool to document both deficits and improvements in balance. By using more challenging test conditions, force platform measures can also reveal subtle balance disorders undetectable by common clinical scales. Furthermore, posturographic techniques may also allow to reliably identify PwMS who are at risk of accidental falls. Although force platform measures offer several theoretical advantages, only few studies extensively investigated their role in better managing PwMS. Standardised procedures, as well as clinical relevance of changes detected by static or dynamic posturography, are still lacking. In this review, we summarized studies which investigated balance deficit by means of force platform measures, focusing on their ability in detecting patients at high risk of falls and in estimating rehabilitation-induced changes, highlighting the pros and the cons with respect to clinical scales. PMID:23766910

  14. New acoustic techniques for leak detection in fossil fuel plant components

    NASA Astrophysics Data System (ADS)

    Parini, G.; Possa, G.

    Two on-line acoustic monitoring techniques for leak detection in feedwater preheaters and boilers of fossil fuel power plants are presented. The leak detection is based on the acoustic noise produced by the turbulent leak outflow. The primary sensors are piezoelectric pressure transducers, installed near the feedwater preheater inlets, in direct contact with the water, or mounted on boiler observation windows. The frequency band of the auscultation ranges from a few kHz, to 10 to 15 kHz. The signals are characterized by their rms value, continuously recorded by means of potentiometric strip chart recorders. The leak occurrence is signalled by the signal rms overcoming predetermined threshold levels. Sensitivity, reliability, acceptance in plant control practice, and costs-benefits balance are satisfactory.

  15. Can Anomalous Amplification be Attained without Postselection?

    PubMed

    Martínez-Rincón, Julián; Liu, Wei-Tao; Viza, Gerardo I; Howell, John C

    2016-03-11

    We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without discarding of data, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected. A tunable phase controls the strength of the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. We show that in the presence of technical noise the effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.

  16. Can Anomalous Amplification be Attained without Postselection?

    NASA Astrophysics Data System (ADS)

    Martínez-Rincón, Julián; Liu, Wei-Tao; Viza, Gerardo I.; Howell, John C.

    2016-03-01

    We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without discarding of data, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected. A tunable phase controls the strength of the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. We show that in the presence of technical noise the effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.

  17. Review of correlation techniques

    NASA Technical Reports Server (NTRS)

    Bowhill, S. A.

    1983-01-01

    Correlation analysis in MST radar to determine the scattered power, Doppler frequency and correlation time for a noisy signal is examined. It is assumed that coherent detection was employed, with two accurately balanced quadrature receiving channels and that coherent integration is performed with a window length significantly less than the correlation time of the signal.

  18. Online breakage detection of multitooth tools using classifier ensembles for imbalanced data

    NASA Astrophysics Data System (ADS)

    Bustillo, Andrés; Rodríguez, Juan J.

    2014-12-01

    Cutting tool breakage detection is an important task, due to its economic impact on mass production lines in the automobile industry. This task presents a central limitation: real data-sets are extremely imbalanced because breakage occurs in very few cases compared with normal operation of the cutting process. In this paper, we present an analysis of different data-mining techniques applied to the detection of insert breakage in multitooth tools. The analysis applies only one experimental variable: the electrical power consumption of the tool drive. This restriction profiles real industrial conditions more accurately than other physical variables, such as acoustic or vibration signals, which are not so easily measured. Many efforts have been made to design a method that is able to identify breakages with a high degree of reliability within a short period of time. The solution is based on classifier ensembles for imbalanced data-sets. Classifier ensembles are combinations of classifiers, which in many situations are more accurate than individual classifiers. Six different base classifiers are tested: Decision Trees, Rules, Naïve Bayes, Nearest Neighbour, Multilayer Perceptrons and Logistic Regression. Three different balancing strategies are tested with each of the classifier ensembles and compared to their performance with the original data-set: Synthetic Minority Over-Sampling Technique (SMOTE), undersampling and a combination of SMOTE and undersampling. To identify the most suitable data-mining solution, Receiver Operating Characteristics (ROC) graph and Recall-precision graph are generated and discussed. The performance of logistic regression ensembles on the balanced data-set using the combination of SMOTE and undersampling turned out to be the most suitable technique. Finally a comparison using industrial performance measures is presented, which concludes that this technique is also more suited to this industrial problem than the other techniques presented in the bibliography.

  19. Ultrasensitive detection of atmospheric trace gases using frequency modulation spectroscopy

    NASA Technical Reports Server (NTRS)

    Cooper, David E.

    1986-01-01

    Frequency modulation (FM) spectroscopy is a new technique that promises to significantly extend the state-of-the-art in point detection of atmospheric trace gases. FM spectroscopy is essentially a balanced bridge optical heterodyne approach in which a small optical absorption or dispersion from an atomic or molecular species of interest generates an easily detected radio frequency (RF) signal. This signal can be monitored using standard RF signal processing techniques and is, in principle, limited only by the shot noise generated in the photodetector by the laser source employed. The use of very high modulation frequencies which exceed the spectral width of the probed absorption line distinguishes this technique from the well-known derivative spectroscopy which makes use of low (kHz) modulation frequencies. FM spectroscopy was recently extended to the 10 micron infrared (IR) spectral region where numerous polyatomic molecules exhibit characteristic vibrational-rotational bands. In conjunction with tunable semiconductor diode lasers, the quantum-noise-limited sensitivity of the technique should allow for the detection of absorptions as small as .00000001 in the IR spectral region. This sensitivity would allow for the detection of H2O2 at concentrations as low as 1 pptv with an integration time of 10 seconds.

  20. Clinical applications of selected binaural effects.

    PubMed

    Noffsinger, D

    1982-01-01

    Examination was made of the behaviors exhibited on selected binaural tasks by 556 persons with diagnosed peripheral hearing loss or central nervous system damage. The tasks used included loudness balancing (LB), intracranial midline imaging (MI), masking level differences (MLD), and binaural beats (BB). The methods used were chosen for their clinical utility. Loudness balancing and midline imaging were of the most diagnostic value when hearing loss was present. Masking level differences were best at detecting pathology which did not produce hearing loss. None of the techniques were sensitive to cortical damage.

  1. Polarization switching detection method using a ferroelectric liquid crystal for dichroic atomic vapor laser lock frequency stabilization techniques.

    PubMed

    Dudzik, Grzegorz; Rzepka, Janusz; Abramski, Krzysztof M

    2015-04-01

    We present a concept of the polarization switching detection method implemented for frequency-stabilized lasers, called the polarization switching dichroic atomic vapor laser lock (PSDAVLL) technique. It is a combination of the well-known dichroic atomic vapor laser lock method for laser frequency stabilization with a synchronous detection system based on the surface-stabilized ferroelectric liquid crystal (SSFLC).The SSFLC is a polarization switch and quarter wave-plate component. This technique provides a 9.6 dB better dynamic range ratio (DNR) than the well-known two-photodiode detection configuration known as the balanced polarimeter. This paper describes the proposed method used practically in the VCSEL laser frequency stabilization system. The applied PSDAVLL method has allowed us to obtain a frequency stability of 2.7×10⁻⁹ and a reproducibility of 1.2×10⁻⁸, with a DNR of detected signals of around 81 dB. It has been shown that PSDAVLL might be successfully used as a method for spectra-stable laser sources.

  2. Impact of rapeseed cropping on the soil carbon balance

    NASA Astrophysics Data System (ADS)

    Moffat, Antje Maria; Herbst, Mathias; Huth, Vytas; Andres, Monique; Augustin, Jürgen

    2015-04-01

    Winter oilseed rape is the dominant biofuel crop in the young moraine landscape in Northern Germany. Since the cultivation of biofuel crops requires sustainability compared to fossil fuels by law, detailed knowledge about their green house gas (GHG) balance is necessary. The soil carbon balance is one of the key contributors to the total GHG balance and also very important for the assessment of soil fertility. However, the knowledge about the impact of different management practices on the soil carbon balance is very limited up to now. Therefore, we investigated the carbon fluxes of winter oilseed rape at field plots near Dedelow/Uckermark in NE Germany with different treatments of fertilization (mineral versus organic) and tillage (no-till and mulch-till versus ploughing). The dynamics of the carbon fluxes are mainly driven by the current climatic conditions but the overall response depends strongly on the ecosystem state (with its physiological and microbiological properties) which is affected by management. To get the full carbon flux dynamics but also the impact of the different management practices, two different approaches were used: The eddy covariance technique to get continuous fluxes throughout the year and the manual chamber technique to detect flux differences between specific management practices. The manual chamber measurements were conducted four-weekly as all-day campaigns using a flow-through non-steady-state closed chamber system. The fluxes in-between campaigns were gap-filled based on functional relationships with soil and air temperature (for the ecosystem respiration) and photosynthetic active radiation (for the gross primary production). All results presented refer to the cropping season 2012-2013. The combination of the two measurement techniques allows the evaluation of chamber fluxes including an independent estimate of the error on the overall balances. Despite the considerable errors, there are significant differences in the soil carbon balance between the tillage and fertilization treatments - ranging from net losses to net gains in the soil carbon stock.

  3. Balance quality assessment as an early indicator of physical frailty in older people.

    PubMed

    Chkeir, Aly; Safieddine, Doha; Bera, D; Collart, M; Novella, J L; Drame, M; Hewson, David J; Duchene, Jacques

    2016-08-01

    Frailty is an increasingly common geriatric condition that results in an increased risk of adverse health outcomes such as falls. The most widely-used means of detecting frailty is the Fried phenotype, which includes several objective measures such as grip strength and gait velocity. One method of screening for falls is to measure balance, which can be done by a range of techniques including the assessment of the Centre of Pressure (CoP) during a balance assessment. The Balance Quality Tester (BQT) is a device based on a commercial bathroom scale that can evaluate balance quality. The BQT provides instantaneously the position of the CoP (stabilogram) in both anteroposterior (AP) and mediolateral (ML) directions and can estimate the vertical ground reaction force. The purpose of this study was to examine the relationship between balance quality assessment and physical frailty. Balance quality was compared to physical frailty in 186 older subjects. Rising rate (RR) was slower and trajectory velocity (TV) was higher in subjects classified as frail for both grip strength and gait velocity (p<;0.05). Balance assessment could be used in conjunction with functional tests of grip strength and gait velocity as a means of screening for frailty.

  4. Sit still and pay attention: Using the Wii Balance-Board to detect lapses in concentration in children during psychophysical testing.

    PubMed

    Jones, Pete R

    2018-05-16

    During psychophysical testing, a loss of concentration can cause observers to answer incorrectly, even when the stimulus is clearly perceptible. Such lapses limit the accuracy and speed of many psychophysical measurements. This study evaluates an automated technique for detecting lapses based on body movement (postural instability). Thirty-five children (8-11 years of age) and 34 adults performed a typical psychophysical task (orientation discrimination) while seated on a Wii Fit Balance Board: a gaming device that measures center of pressure (CoP). Incorrect responses on suprathreshold catch trials provided the "reference standard" measure of when lapses in concentration occurred. Children exhibited significantly greater variability in CoP on lapse trials, indicating that postural instability provides a feasible, real-time index of concentration. Limitations and potential applications of this method are discussed.

  5. Detecting management and fertilization effects on the carbon balance of winter oilseed rape with manual closed chamber measurements: Can we outrange gap-filling uncertainty and spatiotemporal variability?

    NASA Astrophysics Data System (ADS)

    Huth, Vytas; Moffat, Antje Maria; Calmet, Anna; Andres, Monique; Laufer, Judit; Pehle, Natalia; Rach, Bernd; Gundlach, Laura; Augustin, Jürgen

    2017-04-01

    Winter oilseed rape is the dominant biofuel crop in the young moraine landscape in North-Eastern Germany. However, studies on the effect of rapeseed cropping on net ecosystem exchange of CO2 (NEE) and the soil carbon (SC) balance are scarce. SC balance estimates are usually derived from long-term soil sampling field trials where rapeseed is part of different crop rotations. The estimated annual differences linked to rapeseed cropping are rather small (varying between losses of 40 g C m-2 and gains of up to 100 g C m-2). Testing management effects on the NEE and SC balance of cropping systems is best done by comparing plots with different treatments at the same site under the same climate. The soil sampling approach is in the need of field trials that run over decades, which has the disadvantage that management strategies of practical farming may have already changed when the results are derived. Continuous eddy covariance measurements of NEE would require large fields in flat terrain for each of the treatments, which is especially complicated in the heterogeneous landscapes of glacigenic origin of North-Eastern Germany. The common approach of using the chamber technique to derive NEE, however, is subject to the local soil and plant stand heterogeneities due to its tiny footprint. This technique might also disturb the ecosystem, the measurements are usually discontinuous requiring elaborate gap-filling techniques, and it has mostly been used on organic soils where large respiratory C losses occur. Therefore, our aim was to answer, if a combined approach of the eddy covariance and the chamber technique can detect the relatively small NEE and SC differences of rapeseed cropping on mineral soils within a shorter period of time than conventional soil sampling field trials can. We tested the new experimental design taking the advantages of both techniques into account: The eddy covariance tower measuring the NEE dynamics during the year; the chamber measurements to detect the flux differences between specific management practices - with additional chamber measurements installed close to the eddy tower as a reference linking the two techniques. In our experiment, we studied the effect of four different treatments of fertilization (mineral versus organic) and tillage (no-till versus mulch-till versus ploughing) on the NEE of rapeseed cropping for the climatic seasons 2013 to 2015. We compared the NEE of the treatments to the "background" NEE measured by the eddy covariance technique in the nearby reference field for the years 2013 and 2014. With this data, we estimated the uncertainty resulting from gap filling discontinuous chamber measurements and relate it to the observed effects of the four different treatments on the NEE. Here, we present first results on the applicability of the manual-chamber technique to derive the relatively small effects of rapeseed cropping on NEE and SC within a short period of three years of study.

  6. Whole body MRI: Improved Lesion Detection and Characterization With Diffusion Weighted Techniques

    PubMed Central

    Attariwala, Rajpaul; Picker, Wayne

    2013-01-01

    Diffusion-weighted imaging (DWI) is an established functional imaging technique that interrogates the delicate balance of water movement at the cellular level. Technological advances enable this technique to be applied to whole-body MRI. Theory, b-value selection, common artifacts and target to background for optimized viewing will be reviewed for applications in the neck, chest, abdomen, and pelvis. Whole-body imaging with DWI allows novel applications of MRI to aid in evaluation of conditions such as multiple myeloma, lymphoma, and skeletal metastases, while the quantitative nature of this technique permits evaluation of response to therapy. Persisting signal at high b-values from restricted hypercellular tissue and viscous fluid also permits applications of DWI beyond oncologic imaging. DWI, when used in conjunction with routine imaging, can assist in detecting hemorrhagic degradation products, infection/abscess, and inflammation in colitis, while aiding with discrimination of free fluid and empyema, while limiting the need for intravenous contrast. DWI in conjunction with routine anatomic images provides a platform to improve lesion detection and characterization with findings rivaling other combined anatomic and functional imaging techniques, with the added benefit of no ionizing radiation. PMID:23960006

  7. Dual-energy approach to contrast-enhanced mammography using the balanced filter method: spectral optimization and preliminary phantom measurement.

    PubMed

    Saito, Masatoshi

    2007-11-01

    Dual-energy contrast agent-enhanced mammography is a technique of demonstrating breast cancers obscured by a cluttered background resulting from the contrast between soft tissues in the breast. The technique has usually been implemented by exploiting two exposures to different x-ray tube voltages. In this article, another dual-energy approach using the balanced filter method without switching the tube voltages is described. For the spectral optimization of dual-energy mammography using the balanced filters, we applied a theoretical framework reported by Lemacks et al. [Med. Phys. 29, 1739-1751 (2002)] to calculate the signal-to-noise ratio (SNR) in an iodinated contrast agent subtraction image. This permits the selection of beam parameters such as tube voltage and balanced filter material, and the optimization of the latter's thickness with respect to some critical quantity-in this case, mean glandular dose. For an imaging system with a 0.1 mm thick CsI:T1 scintillator, we predict that the optimal tube voltage would be 45 kVp for a tungsten anode using zirconium, iodine, and neodymium balanced filters. A mean glandular dose of 1.0 mGy is required to obtain an SNR of 5 in order to detect 1.0 mg/cm2 iodine in the resulting clutter-free image of a 5 cm thick breast composed of 50% adipose and 50% glandular tissue. In addition to spectral optimization, we carried out phantom measurements to demonstrate the present dual-energy approach for obtaining a clutter-free image, which preferentially shows iodine, of a breast phantom comprising three major components-acrylic spheres, olive oil, and an iodinated contrast agent. The detection of iodine details on the cluttered background originating from the contrast between acrylic spheres and olive oil is analogous to the task of distinguishing contrast agents in a mixture of glandular and adipose tissues.

  8. Glacier and Ice Shelves Studies Using Satellite SAR Interferometry

    NASA Technical Reports Server (NTRS)

    Rignot, Eric

    1999-01-01

    Satellite radar interferometry is a powerful technique to measure the surface velocity and topography of glacier ice. On ice shelves, a quadruple difference technique separates tidal motion from the steady creep flow deformation of ice. The results provide a wealth of information about glacier grounding lines , mass fluxes, stability, elastic properties of ice, and tidal regime. The grounding line, which is where the glacier detaches from its bed and becomes afloat, is detected with a precision of a few tens of meters. Combining this information with satellite radar altimetry makes it possible to measure glacier discharge into the ocean and state of mass balance with greater precision than ever before, and in turn provide a significant revision of past estimates of mass balance of the Greenland and Antarctic Ice Sheets. Analysis of creep rates on floating ice permits an estimation of basal melting at the ice shelf underside. The results reveal that the action of ocean water in sub-ice-shelf cavities has been largely underestimated by oceanographic models and is the dominant mode of mass release to the ocean from an ice shelf. Precise mapping of grounding line positions also permits the detection of grounding line migration, which is a fine indicator of glacier change, independent of our knowledge of snow accumulation and ice melting. This technique has been successfully used to detect the rapid retreat of Pine Island Glacier, the largest ice stream in West Antarctica. Finally, tidal motion of ice shelves measured interferometrically provides a modern, synoptic view of the physical processes which govern the formation of tabular icebergs in the Antarctic.

  9. DNAPL MAPPING AND WATER SATURATION MEASUREMENTS IN 2-D MODELS USING LIGHT TRANSMISSION VISUALIZATION (LTV) TECHNIQUE

    EPA Science Inventory

    • LTV can be used to characterize free phase PCE architecture in 2-D flow chambers without using a dye. • Results to date suggest that error in PCE detection using LTV can be less than 10% if the imaging system is optimized. • Mass balance calculations show a maximum error of 9...

  10. Methods and apparatus for broadband frequency comb stabilization

    DOEpatents

    Cox, Jonathan A; Kaertner, Franz X

    2015-03-17

    Feedback loops can be used to shift and stabilize the carrier-envelope phase of a frequency comb from a mode-locked fibers laser or other optical source. Compared to other frequency shifting and stabilization techniques, feedback-based techniques provide a wideband closed-loop servo bandwidth without optical filtering, beam pointing errors, or group velocity dispersion. It also enables phase locking to a stable reference, such as a Ti:Sapphire laser, continuous-wave microwave or optical source, or self-referencing interferometer, e.g., to within 200 mrad rms from DC to 5 MHz. In addition, stabilized frequency combs can be coherently combined with other stable signals, including other stabilized frequency combs, to synthesize optical pulse trains with pulse durations of as little as a single optical cycle. Such a coherent combination can be achieved via orthogonal control, using balanced optical cross-correlation for timing stabilization and balanced homodyne detection for phase stabilization.

  11. Chaotic time series analysis in economics: Balance and perspectives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faggini, Marisa, E-mail: mfaggini@unisa.it

    2014-12-15

    The aim of the paper is not to review the large body of work concerning nonlinear time series analysis in economics, about which much has been written, but rather to focus on the new techniques developed to detect chaotic behaviours in economic data. More specifically, our attention will be devoted to reviewing some of these techniques and their application to economic and financial data in order to understand why chaos theory, after a period of growing interest, appears now not to be such an interesting and promising research area.

  12. Magnetic resonance imaging of the subthalamic nucleus for deep brain stimulation.

    PubMed

    Chandran, Arjun S; Bynevelt, Michael; Lind, Christopher R P

    2016-01-01

    The subthalamic nucleus (STN) is one of the most important stereotactic targets in neurosurgery, and its accurate imaging is crucial. With improving MRI sequences there is impetus for direct targeting of the STN. High-quality, distortion-free images are paramount. Image reconstruction techniques appear to show the greatest promise in balancing the issue of geometrical distortion and STN edge detection. Existing spin echo- and susceptibility-based MRI sequences are compared with new image reconstruction methods. Quantitative susceptibility mapping is the most promising technique for stereotactic imaging of the STN.

  13. Strain Gauge Balance Calibration and Data Reduction at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Ferris, A. T. Judy

    1999-01-01

    This paper will cover the standard force balance calibration and data reduction techniques used at Langley Research Center. It will cover balance axes definition, balance type, calibration instrumentation, traceability of standards to NIST, calibration loading procedures, balance calibration mathematical model, calibration data reduction techniques, balance accuracy reporting, and calibration frequency.

  14. Differential Sensitivity Between a Virtual Reality Balance Module and Clinically Used Concussion Balance Modalities.

    PubMed

    Teel, Elizabeth F; Gay, Michael R; Arnett, Peter A; Slobounov, Semyon M

    2016-03-01

    Balance assessments are part of the recommended clinical concussion evaluation, along with computerized neuropsychological testing and self-reported symptoms checklists. New technology has allowed for the creation of virtual reality (VR) balance assessments to be used in concussion care, but there is little information on the sensitivity and specificity of these evaluations. The purpose of this study is to establish the sensitivity and specificity of a VR balance module for detecting lingering balance deficits clinical concussion care. Retrospective case-control study. Institutional research laboratory. Normal controls (n = 94) and concussed participants (n = 27). All participants completed a VR balance assessment paradigm. Concussed participants were diagnosed by a Certified Athletic Trainer or physician (with 48 hours postinjury) and tested in the laboratory between 7 and 10 days postinjury. Receiver operating characteristic curves were performed to establish the VR module's sensitivity and specificity for detecting lingering balance deficits. Final balance score. For the VR balance module, a cutoff score of 8.25 was established to maximize sensitivity at 85.7% and specificity at 87.8%. The VR balance module has high sensitivity and specificity for detecting subacute balance deficits after concussive injury. The VR balance has a high subacute sensitivity and specificity as a stand-alone balance assessment tool and may detect ongoing balance deficits not readily detectable by the Balance Error Scoring System or Sensory Organization Test. Virtual reality balance modules may be a beneficial addition to the current clinical concussion diagnostic battery.

  15. Hidden chromosome 8 abnormalities detected by FISH in adult primary myelodysplastic syndromes.

    PubMed

    Panani, Anna D; Pappa, Vasiliki

    2005-01-01

    Acquired clonal chromosomal abnormalities are found in about 30-50% of primary myelodysplastic syndromes (MDS). These abnormalities are predominantly characterized by total/partial chromosomal losses or gains and rarely by balanced structural aberrations. Trisomy 8 represents the most common chromosomal gain. In the present study, the numerical aberration of chromosome 8 was evaluated by the fluorescence in situ hybridization (FISH) technique in MDS, and the results compared with those of conventional cytogenetics. Thirty adult patients with primary MDS, 17 with a normal karyotype and 13 with several chromosomal abnormalities except chromosome 8, were included in this study. On comparing the results of FISH and conventional cytogenetics, a superiority of FISH over the karyotype was detected in 3 cases. In one of them, further cytogenetic analysis confirmed the FISH results. Nevertheless, the FISH technique has limitations, detecting only abnormalities specific for the target FISH probe used In clinical practice, conventional cytogenetics continues to be the basic technique for MDS patient evaluation. However, a large number of metaphases, even those of poor quality, must be analyzed in each case. The FISH technique could be considered to be complementary to achieve a more accurate analysis.

  16. Collective Excitations in Protein as a Measure of Balance Between its Softness and Rigidity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shrestha, Utsab R.; Bhowmik, Debsindhu; Van Delinder, Kurt W.

    Here, we elucidate the protein activity from the perspective of protein softness and flexibility by studying the collective phonon-like excitations in a globular protein, human serum albumin (HSA), and taking advantage of the state-of-the-art inelastic X-ray scattering (IXS) technique. Such excitations demonstrate that the protein becomes softer upon thermal denaturation due to disruption of weak noncovalent bonds. On the other hand, no significant change in the local excitations is detected in ligand- (drugs) bound HSA compared to the ligand-free HSA. These results clearly suggest that the protein conformational flexibility and rigidity are balanced by the native protein structure for biologicalmore » activity.« less

  17. The balance sheet technique. Volume I. The balance sheet analysis technique for preconstruction review of airports and highways

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaBelle, S.J.; Smith, A.E.; Seymour, D.A.

    1977-02-01

    The technique applies equally well to new or existing airports. The importance of accurate accounting of emissions, cannot be overstated. The regional oxidant modelling technique used in conjunction with a balance sheet review must be a proportional reduction technique. This type of emission balancing presumes equality of all sources in the analysis region. The technique can be applied successfully in the highway context, either in planning at the system level or looking only at projects individually. The project-by-project reviews could be used to examine each project in the same way as the airport projects are examined for their impact onmore » regional desired emission levels. The primary limitation of this technique is that it should not be used when simulation models have been used for regional oxidant air quality. In the case of highway projects, the balance sheet technique might appear to be limited; the real limitations are in the transportation planning process. That planning process is not well-suited to the needs of air quality forecasting. If the transportation forecasting techniques are insensitive to change in the variables that affect HC emissions, then no internal emission trade-offs can be identified, and the initial highway emission forecasts are themselves suspect. In general, the balance sheet technique is limited by the quality of the data used in the review. Additionally, the technique does not point out effective trade-off strategies, nor does it indicate when it might be worthwhile to ignore small amounts of excess emissions. Used in the context of regional air quality plans based on proportional reduction models, the balance sheet analysis technique shows promise as a useful method by state or regional reviewing agencies.« less

  18. Incorporating virtual reality graphics with brain imaging for assessment of sport-related concussions.

    PubMed

    Slobounov, Semyon; Sebastianelli, Wayne; Newell, Karl M

    2011-01-01

    There is a growing concern that traditional neuropsychological (NP) testing tools are not sensitive to detecting residual brain dysfunctions in subjects suffering from mild traumatic brain injuries (MTBI). Moreover, most MTBI patients are asymptomatic based on anatomical brain imaging (CT, MRI), neurological examinations and patients' subjective reports within 10 days post-injury. Our ongoing research has documented that residual balance and visual-kinesthetic dysfunctions along with its underlying alterations of neural substrates may be detected in "asymptomatic subjects" by means of Virtual Reality (VR) graphics incorporated with brain imaging (EEG) techniques.

  19. Deep Constrained Siamese Hash Coding Network and Load-Balanced Locality-Sensitive Hashing for Near Duplicate Image Detection.

    PubMed

    Hu, Weiming; Fan, Yabo; Xing, Junliang; Sun, Liang; Cai, Zhaoquan; Maybank, Stephen

    2018-09-01

    We construct a new efficient near duplicate image detection method using a hierarchical hash code learning neural network and load-balanced locality-sensitive hashing (LSH) indexing. We propose a deep constrained siamese hash coding neural network combined with deep feature learning. Our neural network is able to extract effective features for near duplicate image detection. The extracted features are used to construct a LSH-based index. We propose a load-balanced LSH method to produce load-balanced buckets in the hashing process. The load-balanced LSH significantly reduces the query time. Based on the proposed load-balanced LSH, we design an effective and feasible algorithm for near duplicate image detection. Extensive experiments on three benchmark data sets demonstrate the effectiveness of our deep siamese hash encoding network and load-balanced LSH.

  20. Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty: A meta-analysis.

    PubMed

    Moon, Young-Wan; Kim, Hyun-Jung; Ahn, Hyeong-Sik; Park, Chan-Deok; Lee, Dae-Hee

    2016-09-01

    This meta-analysis was designed to compare the accuracy of soft tissue balancing and femoral component rotation as well as change in joint line positions, between the measured resection and gap balancing techniques in primary total knee arthroplasty. Studies were included in the meta-analysis if they compared soft tissue balancing and/or radiologic outcomes in patients who underwent total knee arthroplasty with the gap balancing and measured resection techniques. Comparisons included differences in flexion/extension, medial/lateral flexion, and medial/lateral extension gaps (LEGs), femoral component rotation, and change in joint line positions. Finally, 8 studies identified via electronic (MEDLINE, EMBASE, and the Cochrane Library) and manual searches were included. All 8 studies showed a low risk of selection bias and provided detailed demographic data. There was some inherent heterogeneity due to uncontrolled bias, because all included studies were observational comparison studies. The pooled mean difference in gap differences between the gap balancing and measured resection techniques did not differ significantly (-0.09 mm, 95% confidence interval [CI]: -0.40 to +0.21 mm; P = 0.55), except that the medial/LEG difference was 0.58 mm greater for measured resection than gap balancing (95% CI: -1.01 to -0.15 mm; P = 0.008). Conversely, the pooled mean difference in femoral component external rotation (0.77°, 95% CI: 0.18° to 1.35°; P = 0.01) and joint line change (1.17 mm, 95% CI: 0.82 to 1.52 mm; P < 0.001) were significantly greater for the gap balancing than the measured resection technique. The gap balancing and measured resection techniques showed similar soft tissue balancing, except for medial/LEG difference. However, the femoral component was more externally rotated and the joint line was more elevated with gap balancing than measured resection. These differences were minimal (around 1 mm or 1°) and therefore may have little effect on the biomechanics of the knee joint. This suggests that the gap balancing and measured resection techniques are not mutually exclusive.

  1. [Microarray CGH: principle and use for constitutional disorders].

    PubMed

    Sanlaville, D; Lapierre, J M; Coquin, A; Turleau, C; Vermeesch, J; Colleaux, L; Borck, G; Vekemans, M; Aurias, A; Romana, S P

    2005-10-01

    Chips technology has allowed to miniaturize process making possible to realize in one step and using the same device a lot of chemical reactions. The application of this technology to molecular cytogenetics resulted in the development of comparative genomic hybridization (CGH) on microarrays technique. Using this technique it is possible to detect very small genetic imbalances anywhere in the genome. Its usefulness has been well documented in cancer and more recently in constitutional disorders. In particular it has been used to detect interstitial and subtelomeric submicroscopic imbalances, to characterize their size at the molecular level or to define the breakpoints of translocation. The challenge today is to transfer this technology in laboratory medicine. Nevertheless this technology remains expensive and the existence of numerous sequence polymorphisms makes its interpretation difficult. Finally its is unlikely that it will make karyotyping obsolete as it does not allow to detect balanced rearrangements which after meiotic segregation might result in genome imbalance in the progeny.

  2. The Influence of Joint Distraction Force on the Soft-Tissue Balance Using Modified Gap-Balancing Technique in Posterior-Stabilized Total Knee Arthroplasty.

    PubMed

    Nagai, Kanto; Muratsu, Hirotsugu; Takeoka, Yoshiki; Tsubosaka, Masanori; Kuroda, Ryosuke; Matsumoto, Tomoyuki

    2017-10-01

    During modified gap-balancing technique, there is no consensus on the best method for obtaining appropriate soft-tissue balance and determining the femoral component rotation. Sixty-five varus osteoarthritic patients underwent primary posterior-stabilized total knee arthroplasty using modified gap-balancing technique. The influence of joint distraction force on the soft-tissue balance measurement during the modified gap-balancing technique was evaluated with Offset Repo-Tensor between the osteotomized surfaces at extension, and between femoral posterior condyles and tibial osteotomized surface at flexion of the knee before the resection of femoral posterior condyles. The joint center gap (millimeters) and varus ligament balance (°) were measured under 20, 40, and 60 pounds of joint distraction forces, and the differences in these values at extension and flexion (the value at flexion minus the value at extension) were also calculated. The differences in joint center gap (-6.7, -6.8, and -6.9 mm for 20, 40, and 60 pounds, respectively) and varus ligament balance (3.5°, 3.8°, and 3.8°) at extension and flexion were not significantly different among different joint distraction forces, although the joint center gap and varus ligament balance significantly increased stepwise at extension and flexion as the joint distraction force increased. The difference in joint center gap and varus ligament balance at extension and flexion were consistent even among the different joint distraction forces. This novel index would be useful for the determination of femoral component rotation during the modified gap-balancing technique. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Should Torsion Balance Technique Continue to be Taught to Pharmacy Students?

    PubMed

    Bilger, Rhonda; Chereson, Rasma; Salama, Noha Nabil

    2017-06-01

    Objective. To determine the types of balances used in compounding pharmacies: torsion or digital. Methods. A survey was mailed to the pharmacist-in-charge at 698 pharmacies, representing 47% of the pharmacies in Missouri as of July 2013. The pharmacies were randomly selected and stratified by region into eight regions to ensure a representative sample. Information was gathered regarding the type and use of balances and pharmacists' perspectives on the need to teach torsion balance technique to pharmacy students. Results. The response rate for the survey was 53.3%. Out of the total responses received, those pharmacies having a torsion balance, digital balance or both were 46.8%, 27.4% and 11.8%, respectively. About 68.3% of respondents compound prescriptions. The study showed that 52% of compounding pharmacies use torsion balances in their practice. Of those with a balance in their pharmacy, 65.6% favored continuation of torsion balance instruction. Conclusions. Digital balances have become increasingly popular and have replaced torsion balances in some pharmacies, especially those that compound a significant number of prescriptions. The results of this study indicate that torsion balances remain integral to compounding practice. Therefore, students should continue being taught torsion balance technique at the college.

  4. Should Torsion Balance Technique Continue to be Taught to Pharmacy Students?

    PubMed Central

    Bilger, Rhonda; Chereson, Rasma

    2017-01-01

    Objective. To determine the types of balances used in compounding pharmacies: torsion or digital. Methods. A survey was mailed to the pharmacist-in-charge at 698 pharmacies, representing 47% of the pharmacies in Missouri as of July 2013. The pharmacies were randomly selected and stratified by region into eight regions to ensure a representative sample. Information was gathered regarding the type and use of balances and pharmacists’ perspectives on the need to teach torsion balance technique to pharmacy students. Results. The response rate for the survey was 53.3%. Out of the total responses received, those pharmacies having a torsion balance, digital balance or both were 46.8%, 27.4% and 11.8%, respectively. About 68.3% of respondents compound prescriptions. The study showed that 52% of compounding pharmacies use torsion balances in their practice. Of those with a balance in their pharmacy, 65.6% favored continuation of torsion balance instruction. Conclusions. Digital balances have become increasingly popular and have replaced torsion balances in some pharmacies, especially those that compound a significant number of prescriptions. The results of this study indicate that torsion balances remain integral to compounding practice. Therefore, students should continue being taught torsion balance technique at the college. PMID:28720913

  5. A polarization-division multiplexing SSB-OFDM system with beat interference cancellation receivers

    NASA Astrophysics Data System (ADS)

    Yang, Peiling; Ma, Jianxin; Zhang, Junyi

    2018-06-01

    In this paper, we have proposed a polarization-division multiplexing (PDM) single-sideband optical orthogonal frequency division multiplexing (SSB-OOFDM) scheme with signal-signal beat interference cancellation receivers with balanced detection (ICRBD). This system can double channel capacity and improve spectrum efficiency (SE) with the reduced guard band (GB) due to the PDM. Multiple input multiple output (MIMO) technique is used to solve polarization mode dispersion (PMD) associated with channel estimation and equalization. By simulation, we demonstrate the efficacy of the proposed technique for a 2 ×40 Gbit/s 16-QAM SSB-PDM-OOFDM system according to the error vector magnitude (EVM) and the constellation diagrams.

  6. Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty

    PubMed Central

    Moon, Young-Wan; Kim, Hyun-Jung; Ahn, Hyeong-Sik; Park, Chan-Deok; Lee, Dae-Hee

    2016-01-01

    Abstract Background: This meta-analysis was designed to compare the accuracy of soft tissue balancing and femoral component rotation as well as change in joint line positions, between the measured resection and gap balancing techniques in primary total knee arthroplasty. Methods: Studies were included in the meta-analysis if they compared soft tissue balancing and/or radiologic outcomes in patients who underwent total knee arthroplasty with the gap balancing and measured resection techniques. Comparisons included differences in flexion/extension, medial/lateral flexion, and medial/lateral extension gaps (LEGs), femoral component rotation, and change in joint line positions. Finally, 8 studies identified via electronic (MEDLINE, EMBASE, and the Cochrane Library) and manual searches were included. All 8 studies showed a low risk of selection bias and provided detailed demographic data. There was some inherent heterogeneity due to uncontrolled bias, because all included studies were observational comparison studies. Results: The pooled mean difference in gap differences between the gap balancing and measured resection techniques did not differ significantly (−0.09 mm, 95% confidence interval [CI]: −0.40 to +0.21 mm; P = 0.55), except that the medial/LEG difference was 0.58 mm greater for measured resection than gap balancing (95% CI: −1.01 to −0.15 mm; P = 0.008). Conversely, the pooled mean difference in femoral component external rotation (0.77°, 95% CI: 0.18° to 1.35°; P = 0.01) and joint line change (1.17 mm, 95% CI: 0.82 to 1.52 mm; P < 0.001) were significantly greater for the gap balancing than the measured resection technique. Conclusion: The gap balancing and measured resection techniques showed similar soft tissue balancing, except for medial/LEG difference. However, the femoral component was more externally rotated and the joint line was more elevated with gap balancing than measured resection. These differences were minimal (around 1 mm or 1°) and therefore may have little effect on the biomechanics of the knee joint. This suggests that the gap balancing and measured resection techniques are not mutually exclusive. PMID:27684862

  7. Dynamic balance abilities of collegiate men for the bench press.

    PubMed

    Piper, Timothy J; Radlo, Steven J; Smith, Thomas J; Woodward, Ryan W

    2012-12-01

    This study investigated the dynamic balance detection ability of college men for the bench press exercise. Thirty-five college men (mean ± SD: age = 22.4 ± 2.76 years, bench press experience = 8.3 ± 2.79 years, and estimated 1RM = 120.1 ± 21.8 kg) completed 1 repetition of the bench press repetitions for each of 3 bar loading arrangements. In a randomized fashion, subjects performed the bench press with a 20-kg barbell loaded with one of the following: a balanced load, one 20-kg plate on each side; an imbalanced asymmetrical load, one 20-kg plate on one side and a 20-kg plate plus a 1.25-kg plate on the other side; or an imbalanced asymmetrical center of mass, 20-kg plate on one side and sixteen 1.25-kg plates on the other side. Subjects were blindfolded and wore ear protection throughout all testing to decrease the ability to otherwise detect loads. Binomial data analysis indicated that subjects correctly detected the imbalance of the imbalanced asymmetrical center of mass condition (p[correct detection] = 0.89, p < 0.01) but did not correctly detect the balanced condition (p[correct detection] = 0.46, p = 0.74) or the imbalanced asymmetrical condition (p[correct detection] = 0.60, p = 0.31). Although it appears that a substantial shift in the center of mass of plates leads to the detection of barbell imbalance, minor changes of the addition of 1.25 kg (2.5 lb) to the asymmetrical condition did not result in consistent detection. Our data indicate that the establishment of a biofeedback loop capable of determining balance detection was only realized under a high degree of imbalance. Although balance detection was not present in either the even or the slightly uneven loading condition, the inclusion of balance training for upper body may be futile if exercises are unable to establish such a feedback loop and thus eliciting an improvement of balance performance.

  8. The comparison of femoral component rotational alignment with transepicondylar axis in mobile bearing TKA, CT-scan study.

    PubMed

    Witoolkollachit, Polawat; Seubchompoo, Onuma

    2008-07-01

    The tibial axis referencing method with a balanced tension flexion gap at 90 degrees knee flexion provides adequate femoral component rotation usually in external rotation, the trans-epicondylar line being parallel to the proximal tibial cut. The LCS mobile bearing TKA uses this technique to automatically determine the femoral component rotation with desired tension. The determination of the epicondyles may lead to some confusion. On the lateral side, the prominence of the lateral condyle makes it easy to define. However on the medial side, some surgeons use the prominent part of the medial epicondyle (well recognized on CT scan as the most proximal ridge that gives insertion to the superficial collateral ligament) and use the anatomical transepicondylar axis (aTEA). Other surgeons use the depression below called sulcus that defines the surgical transepicondylar axis (sTEA). The authors evaluated 40 clinically successful mobile bearing TKA in 33 patients. All the knees were performed by single surgeon and the rotational alignment of the femoral component was applied with balanced flexion gap technique. Post-op CT-scans were done in all knees with 2-mm interval and measurement of the different angles (between aTEA and the prosthetic posterior condylar line and between the sTEA and the prosthetic posterior condylar line) with the UTHSCSA Imagetool (IT) version 3 from the University of Texas Health Science Center at San Antonio. The authors found that the mean femoral implant angle was in 2.39 degrees (SD = 2.80) of internal rotation with reference to the aTEA and in 1.34 degrees (SD = 1.57 degrees) of external rotation with reference to the sTEA when the medial sulcus was perfectly detected (nine knees, 22.5%). The angle between the aTEA and the sTEA was -3.98 degrees (SD = 1.05 degrees). No patella subluxation was identified. Nineteen or 47.5% of the femoral components were in internal or external femoral rotation of more than 3 degrees to the aTEA. When sTEA was detected, no knee was in internal or external rotation more than 3 degrees to sTEA. The balanced flexion gap technique positions the femoral component in external rotation with the LCS TKA. Within 3 degrees to aTEA or sTEA, this technique produced femoral rotational angle closer to sTEA when the sulcus was detected and produced a wide range of different angles when compared to aTEA. However sTEA is not the consistent bony landmark. This technique is a reliable method to determine femoral rotational alignment.

  9. Gap-balancing technique combined with patient-specific instrumentation in TKA.

    PubMed

    Hommel, Hagen; Perka, Carsten

    2015-11-01

    Combining patient-specific instrumentation (PSI) with a balancer device in total knee arthroplasty (TKA) to achieve functional femoral rotational alignment is a novel technique. The primary goal of this study was to introduce a new method to combine PSI with a gap-balancing technique and to determine the impact of the technique on rotation of the femoral component. Twenty-five primary TKAs (15 women, 10 men) were prospectively studied. All TKAs involved PSI with an associated gap-balancing device. Front plane alignment was performed intraoperatively with the PSI, followed by rectangular, symmetrical extension and creation of a flexion gap using the balancer device to set the femoral rotation. Femoral component rotation was between 3° internal and 6° external rotation versus the transepicondylar axis. There were no postoperative signs of patellofemoral dysfunction. In no cases was the resulting joint line displacement >3 mm. The mean elevation was 1.2 ± 0.9 mm (range 0-3). The leg axis was straight in all cases (±3°), at a mean of 1.6° ± 1.0° varus (range 0°-3° varus). PSI was with the gap-balancing technique was successfully used without affecting anatomical alignment. With the balancer device, PSI can be used more widely than techniques based solely on landmarks, as the soft-tissue tension can be taken into account, thus virtually eliminating flexion instabilities.

  10. Detection and compensation of power imbalances for DP-QAM transmitter using reconfigurable interference

    NASA Astrophysics Data System (ADS)

    Yue, Yang; Wang, Qiang; Zhang, Bo; Vovan, Andre; Anderson, Jon

    2017-01-01

    DP-QAM is one of the most promising paths towards 400-Gb/s and 1-Tb/s commercial optical communications systems. For DP-QAM transmitter, different tributary channel powers lead to IQ or XY power imbalance. Large uncompensated IQ or XY power imbalance can significantly degrade the performance in the coherent optical communications system. In this work, we propose and experimentally demonstrate a technique to detect and compensate DP-QAM transmitter power imbalances for tributary channels. By reconfigurably interfering de-skewed identical BPSK channels, the optical powers of any two tributaries can be balanced by minimizing the output power from their optical interference.

  11. T700 power turbine rotor multiplane/multispeed balancing demonstration

    NASA Technical Reports Server (NTRS)

    Burgess, G.; Rio, R.

    1979-01-01

    Research was conducted to demonstrate the ability of influence coefficient based multispeed balancing to control rotor vibration through bending criticals. Rotor dynamic analyses were conducted of the General Electric T700 power turbine rotor. The information was used to generate expected rotor behavior for optimal considerations in designing a balance rig and a balance technique. The rotor was successfully balanced 9500 rpm. Uncontrollable coupling behavior prevented observations through the 16,000 rpm service speed. The balance technique is practical and with additional refinement it can meet production standards.

  12. Effects on Hamstring Muscle Extensibility, Muscle Activity, and Balance of Different Stretching Techniques

    PubMed Central

    Lim, Kyoung-Il; Nam, Hyung-Chun; Jung, Kyoung-Sim

    2014-01-01

    [Purpose] The purpose of this study was to investigate the effects of two different stretching techniques on range of motion (ROM), muscle activation, and balance. [Subjects] For the present study, 48 adults with hamstring muscle tightness were recruited and randomly divided into three groups: a static stretching group (n=16), a PNF stretching group (n=16), a control group (n=16). [Methods] Both of the stretching techniques were applied to the hamstring once. Active knee extension angle, muscle activation during maximum voluntary isometric contraction (MVC), and static balance were measured before and after the application of each stretching technique. [Results] Both the static stretching and the PNF stretching groups showed significant increases in knee extension angle compared to the control group. However, there were no significant differences in muscle activation or balance between the groups. [Conclusion] Static stretching and PNF stretching techniques improved ROM without decrease in muscle activation, but neither of them exerted statistically significant effects on balance. PMID:24648633

  13. Impact of deforestation on local precipitation patterns over the Da River basin, Vietnam

    NASA Astrophysics Data System (ADS)

    Anghileri, Daniela; Spartà, Daniele; Castelletti, Andrea; Boschetti, Mirco

    2014-05-01

    Change in land cover, e.g. from forest to bare soil, might severely impact the hydrological cycle at the river basin scale by altering the balance between rainfall and evaporation, ultimately affecting streamflow dynamics. These changes generally occur over decades, but they might be much more rapid in developing countries, where economic growth and growing population may cause abrupt changes in landscape and ecosystem. Detecting, analysing and modelling these changes is an essential step to design mitigation strategies and adaptation plans, balancing economic development and ecosystem protection. In this work we investigate the impact of land cover changes on the water cycle in the Da River basin, Vietnam. More precisely, the objective is to evaluate the interlink between deforestation and precipitation. The case study is particularly interesting because Vietnam is one of the world fastest growing economies and natural resources have been considerably exploited to support after-war development. Vietnam has the second highest rate of deforestation of primary forests in the world, second to only Nigeria (FAO 2005), with associated problems like abrupt change in run-off, erosion, sediment transport and flash floods. We performed land cover evaluation by combining literature information and Remote Sensing techniques, using Landsat images. We then analysed time series of precipitation observed on the period 1960-2011 in several stations located in the catchment area. We used multiple trend detection techniques, both state-of-the-art (e.g., Linear regression and Mann-Kendall) and novel trend detection techniques (Moving Average on Shifting Horizon), to investigate trends in seasonal pattern of precipitation. Results suggest that deforestation may induce a negative trend in the precipitation volume. The effect is mainly recognizable at the beginning and at the end of the monsoon season, when the local mechanisms of precipitation formation prevail over the large scale ones.

  14. Dynamic balance in elite karateka.

    PubMed

    Zago, Matteo; Mapelli, Andrea; Shirai, Yuri Francesca; Ciprandi, Daniela; Lovecchio, Nicola; Galvani, Christel; Sforza, Chiarella

    2015-12-01

    In karate, balance control represents a key performance determinant. With the hypothesis that high-level athletes display advanced balance abilities, the purpose of the current study was to quantitatively investigate the motor strategies adopted by elite and non-elite karateka to maintain balance control in competition. The execution of traditional karate techniques (kihon) in two groups of elite Masters (n = 6, 31 ± 19 years) and non-elite Practitioners (n = 4, 25 ± 9 years) was compared assessing body center of mass (CoM) kinematics and other relevant parameters like step width and angular joint behavior. In the considered kihon sequence, normalized average CoM height was 8% lower (p < 0.05), while CoM displacement in the horizontal direction was significantly higher in Masters than in Practitioners (2.5 vs. 1.9 m, p < 0.05), as well as CoM average velocity and rms acceleration (p < 0.05). Step width was higher in Masters in more than half of the sequence steps (p < 0.05). Results suggest that elite karateka showed a refined dynamic balance control, obtained through the increase of the base of support and different maneuvers of lower limbs. The proposed method could be used to objectively detect talented karateka, to measure proficiency level and to assess training effectiveness. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Standoff concealed weapon detection using a 350-GHz radar imaging system

    NASA Astrophysics Data System (ADS)

    Sheen, David M.; Hall, Thomas E.; Severtsen, Ronald H.; McMakin, Douglas L.; Hatchell, Brian K.; Valdez, Patrick L. J.

    2010-04-01

    The sub-millimeter (sub-mm) wave frequency band from 300 - 1000 GHz is currently being developed for standoff concealed weapon detection imaging applications. This frequency band is of interest due to the unique combination of high resolution and clothing penetration. The Pacific Northwest National Laboratory (PNNL) is currently developing a 350 GHz, active, wideband, three-dimensional, radar imaging system to evaluate the feasibility of active sub-mm imaging for standoff detection. Standoff concealed weapon and explosive detection is a pressing national and international need for both civilian and military security, as it may allow screening at safer distances than portal screening techniques. PNNL has developed a prototype active wideband 350 GHz radar imaging system based on a wideband, heterodyne, frequency-multiplier-based transceiver system coupled to a quasi-optical focusing system and high-speed rotating conical scanner. This prototype system operates at ranges up to 10+ meters, and can acquire an image in 10 - 20 seconds, which is fast enough to scan cooperative personnel for concealed weapons. The wideband operation of this system provides accurate ranging information, and the images obtained are fully three-dimensional. During the past year, several improvements to the system have been designed and implemented, including increased imaging speed using improved balancing techniques, wider bandwidth, and improved image processing techniques. In this paper, the imaging system is described in detail and numerous imaging results are presented.

  16. Efficient IDUA Gene Mutation Detection with Combined Use of dHPLC and Dried Blood Samples

    PubMed Central

    Duarte, Ana Joana; Vieira, Luis

    2013-01-01

    Objectives. Development of a simple mutation directed method in order to allow lowering the cost of mutation testing using an easily obtainable biological material. Assessment of the feasibility of such method was tested using a GC-rich amplicon. Design and Methods. A method of denaturing high-performance liquid chromatography (dHPLC) was improved and implemented as a technique for the detection of variants in exon 9 of the IDUA gene. The optimized method was tested in 500 genomic DNA samples obtained from dried blood spots (DBS). Results. With this dHPLC approach it was possible to detect different variants, including the common p.Trp402Ter mutation in the IDUA gene. The high GC content did not interfere with the resolution and reliability of this technique, and discrimination of G-C transversions was also achieved. Conclusion. This PCR-based dHPLC method is proved to be a rapid, a sensitive, and an excellent option for screening numerous samples obtained from DBS. Furthermore, it resulted in the consistent detection of clearly distinguishable profiles of the common p.Trp402Ter IDUA mutation with an advantageous balance of cost and technical requirements. PMID:27335677

  17. Rapid pupil-based assessment of glaucomatous damage.

    PubMed

    Chen, Yanjun; Wyatt, Harry J; Swanson, William H; Dul, Mitchell W

    2008-06-01

    To investigate the ability of a technique employing pupillometry and functionally-shaped stimuli to assess loss of visual function due to glaucomatous optic neuropathy. Pairs of large stimuli, mirror images about the horizontal meridian, were displayed alternately in the upper and lower visual field. Pupil diameter was recorded and analyzed in terms of the "contrast balance" (relative sensitivity to the upper and lower stimuli), and the pupil constriction amplitude to upper and lower stimuli separately. A group of 40 patients with glaucoma was tested twice in a first session, and twice more in a second session, 1 to 3 weeks later. A group of 40 normal subjects was tested with the same protocol. Results for the normal subjects indicated functional symmetry in upper/lower retina, on average. Contrast balance results for the patients with glaucoma differed from normal: half the normal subjects had contrast balance within 0.06 log unit of equality and 80% had contrast balance within 0.1 log unit. Half the patients had contrast balances more than 0.1 log unit from equality. Patient contrast balances were moderately correlated with predictions from perimetric data (r = 0.37, p < 0.00001). Contrast balances correctly classified visual field damage in 28 patients (70%), and response amplitudes correctly classified 24 patients (60%). When contrast balance and response amplitude were combined, receiver operating characteristic area for discriminating glaucoma from normal was 0.83. Pupillary evaluation of retinal asymmetry provides a rapid method for detecting and classifying visual field defects. In this patient population, classification agreed with perimetry in 70% of eyes.

  18. An intelligent clinical decision support system for patient-specific predictions to improve cervical intraepithelial neoplasia detection.

    PubMed

    Bountris, Panagiotis; Haritou, Maria; Pouliakis, Abraham; Margari, Niki; Kyrgiou, Maria; Spathis, Aris; Pappas, Asimakis; Panayiotides, Ioannis; Paraskevaidis, Evangelos A; Karakitsos, Petros; Koutsouris, Dimitrios-Dionyssios

    2014-01-01

    Nowadays, there are molecular biology techniques providing information related to cervical cancer and its cause: the human Papillomavirus (HPV), including DNA microarrays identifying HPV subtypes, mRNA techniques such as nucleic acid based amplification or flow cytometry identifying E6/E7 oncogenes, and immunocytochemistry techniques such as overexpression of p16. Each one of these techniques has its own performance, limitations and advantages, thus a combinatorial approach via computational intelligence methods could exploit the benefits of each method and produce more accurate results. In this article we propose a clinical decision support system (CDSS), composed by artificial neural networks, intelligently combining the results of classic and ancillary techniques for diagnostic accuracy improvement. We evaluated this method on 740 cases with complete series of cytological assessment, molecular tests, and colposcopy examination. The CDSS demonstrated high sensitivity (89.4%), high specificity (97.1%), high positive predictive value (89.4%), and high negative predictive value (97.1%), for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+). In comparison to the tests involved in this study and their combinations, the CDSS produced the most balanced results in terms of sensitivity, specificity, PPV, and NPV. The proposed system may reduce the referral rate for colposcopy and guide personalised management and therapeutic interventions.

  19. An Intelligent Clinical Decision Support System for Patient-Specific Predictions to Improve Cervical Intraepithelial Neoplasia Detection

    PubMed Central

    Bountris, Panagiotis; Haritou, Maria; Pouliakis, Abraham; Margari, Niki; Kyrgiou, Maria; Spathis, Aris; Pappas, Asimakis; Panayiotides, Ioannis; Paraskevaidis, Evangelos A.; Karakitsos, Petros; Koutsouris, Dimitrios-Dionyssios

    2014-01-01

    Nowadays, there are molecular biology techniques providing information related to cervical cancer and its cause: the human Papillomavirus (HPV), including DNA microarrays identifying HPV subtypes, mRNA techniques such as nucleic acid based amplification or flow cytometry identifying E6/E7 oncogenes, and immunocytochemistry techniques such as overexpression of p16. Each one of these techniques has its own performance, limitations and advantages, thus a combinatorial approach via computational intelligence methods could exploit the benefits of each method and produce more accurate results. In this article we propose a clinical decision support system (CDSS), composed by artificial neural networks, intelligently combining the results of classic and ancillary techniques for diagnostic accuracy improvement. We evaluated this method on 740 cases with complete series of cytological assessment, molecular tests, and colposcopy examination. The CDSS demonstrated high sensitivity (89.4%), high specificity (97.1%), high positive predictive value (89.4%), and high negative predictive value (97.1%), for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+). In comparison to the tests involved in this study and their combinations, the CDSS produced the most balanced results in terms of sensitivity, specificity, PPV, and NPV. The proposed system may reduce the referral rate for colposcopy and guide personalised management and therapeutic interventions. PMID:24812614

  20. Distributed Parallel Processing and Dynamic Load Balancing Techniques for Multidisciplinary High Speed Aircraft Design

    NASA Technical Reports Server (NTRS)

    Krasteva, Denitza T.

    1998-01-01

    Multidisciplinary design optimization (MDO) for large-scale engineering problems poses many challenges (e.g., the design of an efficient concurrent paradigm for global optimization based on disciplinary analyses, expensive computations over vast data sets, etc.) This work focuses on the application of distributed schemes for massively parallel architectures to MDO problems, as a tool for reducing computation time and solving larger problems. The specific problem considered here is configuration optimization of a high speed civil transport (HSCT), and the efficient parallelization of the embedded paradigm for reasonable design space identification. Two distributed dynamic load balancing techniques (random polling and global round robin with message combining) and two necessary termination detection schemes (global task count and token passing) were implemented and evaluated in terms of effectiveness and scalability to large problem sizes and a thousand processors. The effect of certain parameters on execution time was also inspected. Empirical results demonstrated stable performance and effectiveness for all schemes, and the parametric study showed that the selected algorithmic parameters have a negligible effect on performance.

  1. Shaping abilities of two different engine-driven rotary nickel titanium systems or stainless steel balanced-force technique in mandibular molars.

    PubMed

    Matwychuk, Michael J; Bowles, Walter R; McClanahan, Scott B; Hodges, Jim S; Pesun, Igor J

    2007-07-01

    The purpose of this study was to compare apical transportation, working-length changes, and instrumentation time by using nickel-titanium (Ni-Ti) rotary file systems (crown-down method) or stainless steel hand files (balanced-force technique) in mesiobuccal canals of extracted mandibular molars. The curvature of each canal was determined and teeth placed into three equivalent groups. Group 1 was instrumented with Sequence (Brasseler USA, Savannah, GA) rotary files, group 2 with Liberator (Miltex Inc, York, PA) rotary files, and group 3 with Flex-R (Union Broach, New York, NY) files. Pre- and postoperative radiographs were superimposed to measure loss of working length and apical transportation as shown by changes in radius of curvature and the long-axis canal angle. Sequence rotary files, Liberator rotary files, and Flex-R hand files had similar effects on apical canal transportation and changes in working length, with no significant differences detected among the 3 groups. Hand instrumentation times were longer than with either Ni-Ti rotary group, whereas the rotary NiTi groups had a higher incidence of fracture.

  2. Assessment of Evapotranspiration and Soil Moisture Content Across Different Scales of Observation

    PubMed Central

    Verstraeten, Willem W.; Veroustraete, Frank; Feyen, Jan

    2008-01-01

    The proper assessment of evapotranspiration and soil moisture content are fundamental in food security research, land management, pollution detection, nutrient flows, (wild-) fire detection, (desert) locust, carbon balance as well as hydrological modelling; etc. This paper takes an extensive, though not exhaustive sample of international scientific literature to discuss different approaches to estimate land surface and ecosystem related evapotranspiration and soil moisture content. This review presents: (i)a summary of the generally accepted cohesion theory of plant water uptake and transport including a shortlist of meteorological and plant factors influencing plant transpiration;(ii)a summary on evapotranspiration assessment at different scales of observation (sap-flow, porometer, lysimeter, field and catchment water balance, Bowen ratio, scintillometer, eddy correlation, Penman-Monteith and related approaches);(iii)a summary on data assimilation schemes conceived to estimate evapotranspiration using optical and thermal remote sensing; and(iv)for soil moisture content, a summary on soil moisture retrieval techniques at different spatial and temporal scales is presented. Concluding remarks on the best available approaches to assess evapotranspiration and soil moisture content with and emphasis on remote sensing data assimilation, are provided. PMID:27879697

  3. Assessment of Evapotranspiration and Soil Moisture Content Across Different Scales of Observation.

    PubMed

    Verstraeten, Willem W; Veroustraete, Frank; Feyen, Jan

    2008-01-09

    The proper assessment of evapotranspiration and soil moisture content arefundamental in food security research, land management, pollution detection, nutrient flows,(wild-) fire detection, (desert) locust, carbon balance as well as hydrological modelling; etc.This paper takes an extensive, though not exhaustive sample of international scientificliterature to discuss different approaches to estimate land surface and ecosystem relatedevapotranspiration and soil moisture content. This review presents:(i) a summary of the generally accepted cohesion theory of plant water uptake andtransport including a shortlist of meteorological and plant factors influencing planttranspiration;(ii) a summary on evapotranspiration assessment at different scales of observation (sapflow,porometer, lysimeter, field and catchment water balance, Bowen ratio,scintillometer, eddy correlation, Penman-Monteith and related approaches);(iii) a summary on data assimilation schemes conceived to estimate evapotranspirationusing optical and thermal remote sensing; and(iv) for soil moisture content, a summary on soil moisture retrieval techniques atdifferent spatial and temporal scales is presented.Concluding remarks on the best available approaches to assess evapotranspiration and soilmoisture content with and emphasis on remote sensing data assimilation, are provided.

  4. Strain Gauge Balance Uncertainty Analysis at NASA Langley: A Technical Review

    NASA Technical Reports Server (NTRS)

    Tripp, John S.

    1999-01-01

    This paper describes a method to determine the uncertainties of measured forces and moments from multi-component force balances used in wind tunnel tests. A multivariate regression technique is first employed to estimate the uncertainties of the six balance sensitivities and 156 interaction coefficients derived from established balance calibration procedures. These uncertainties are then employed to calculate the uncertainties of force-moment values computed from observed balance output readings obtained during tests. Confidence and prediction intervals are obtained for each computed force and moment as functions of the actual measurands. Techniques are discussed for separate estimation of balance bias and precision uncertainties.

  5. Differential sensitivity between a virtual reality (VR) balance module and clinically used concussion balance modalities

    PubMed Central

    Teel, Elizabeth F; Gay, Michael R; Arnett, Peter A; Slobounov, Semyon M

    2015-01-01

    Objective Balance assessments are part of the recommended clinical concussion evaluation, along with computerized neuropsychological testing and self-reported symptoms checklists. New technology has allowed for the creation of virtual reality (VR) balance assessments to be used in concussion care, but there is little information on the sensitivity and specificity of these evaluations. The purpose of this study is to establish the sensitivity and specificity of a VR balance module for detecting lingering balance deficits clinical concussion care. Design Retrospective, case-control study Setting Institutional research laboratory Participants Normal controls (n=94) and concussed participants (n=27) Interventions All participants completed a VR balance assessment paradigm. Concussed participants were diagnosed by a Certified Athletic Trainer or physician (with 48 hours post-injury) and tested in the lab between 7-10 days post-injury. ROC curves were performed in order to establish the VR module’s sensitivity and specificity for detecting lingering balance deficits. Main Outcome Measures Final balance score Results For the VR balance module, a cutoff score of 8.25 was established to maximize sensitivity at 85.7% and specificity at 87.8%. Conclusions The VR balance module has high sensitivity and specificity for detecting sub-acute balance deficits after concussive injury. PMID:26505696

  6. Science and Technology Review December 2006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radousky, H B

    2006-10-30

    This month's issue has the following articles: (1) Livermore's Biosecurity Research Directly Benefits Public Health--Commentary by Raymond J. Juzaitis; (2) Diagnosing Flu Fast--Livermore's FluIDx device can diagnose flu and four other respiratory viruses in just two hours; (3) An Action Plan to Reopen a Contaminated Airport--New planning tools and faster sample analysis methods will hasten restoration of a major airport to full use following a bioterrorist attack; (4) Early Detection of Bone Disease--A Livermore technique detects small changes in skeletal calcium balance that may signal bone disease; and (5) Taking a Gander with Gamma Rays--Gamma rays may be the nextmore » source for looking deep inside the atom.« less

  7. Squids in the Study of Cerebral Magnetic Field

    NASA Astrophysics Data System (ADS)

    Romani, G. L.; Narici, L.

    The following sections are included: * INTRODUCTION * HISTORICAL OVERVIEW * NEUROMAGNETIC FIELDS AND AMBIENT NOISE * DETECTORS * Room temperature sensors * SQUIDs * DETECTION COILS * Magnetometers * Gradiometers * Balancing * Planar gradiometers * Choice of the gradiometer parameters * MODELING * Current pattern due to neural excitations * Action potentials and postsynaptic currents * The current dipole model * Neural population and detected fields * Spherically bounded medium * SPATIAL CONFIGURATION OF THE SENSORS * SOURCE LOCALIZATION * Localization procedure * Experimental accuracy and reproducibility * SIGNAL PROCESSING * Analog Filtering * Bandpass filters * Line rejection filters * DATA ANALYSIS * Analysis of evoked/event-related responses * Simple average * Selected average * Recursive techniques * Similarity analysis * Analysis of spontaneous activity * Mapping and localization * EXAMPLES OF NEUROMAGNETIC STUDIES * Neuromagnetic measurements * Studies on the normal brain * Clinical applications * Epilepsy * Tinnitus * CONCLUSIONS * ACKNOWLEDGEMENTS * REFERENCES

  8. Simulation of deterministic energy-balance particle agglomeration in turbulent liquid-solid flows

    NASA Astrophysics Data System (ADS)

    Njobuenwu, Derrick O.; Fairweather, Michael

    2017-08-01

    An efficient technique to simulate turbulent particle-laden flow at high mass loadings within the four-way coupled simulation regime is presented. The technique implements large-eddy simulation, discrete particle simulation, a deterministic treatment of inter-particle collisions, and an energy-balanced particle agglomeration model. The algorithm to detect inter-particle collisions is such that the computational costs scale linearly with the number of particles present in the computational domain. On detection of a collision, particle agglomeration is tested based on the pre-collision kinetic energy, restitution coefficient, and van der Waals' interactions. The performance of the technique developed is tested by performing parametric studies on the influence of the restitution coefficient (en = 0.2, 0.4, 0.6, and 0.8), particle size (dp = 60, 120, 200, and 316 μm), Reynolds number (Reτ = 150, 300, and 590), and particle concentration (αp = 5.0 × 10-4, 1.0 × 10-3, and 5.0 × 10-3) on particle-particle interaction events (collision and agglomeration). The results demonstrate that the collision frequency shows a linear dependency on the restitution coefficient, while the agglomeration rate shows an inverse dependence. Collisions among smaller particles are more frequent and efficient in forming agglomerates than those of coarser particles. The particle-particle interaction events show a strong dependency on the shear Reynolds number Reτ, while increasing the particle concentration effectively enhances particle collision and agglomeration whilst having only a minor influence on the agglomeration rate. Overall, the sensitivity of the particle-particle interaction events to the selected simulation parameters is found to influence the population and distribution of the primary particles and agglomerates formed.

  9. The development of an efficient mass balance approach for the purity assignment of organic calibration standards.

    PubMed

    Davies, Stephen R; Alamgir, Mahiuddin; Chan, Benjamin K H; Dang, Thao; Jones, Kai; Krishnaswami, Maya; Luo, Yawen; Mitchell, Peter S R; Moawad, Michael; Swan, Hilton; Tarrant, Greg J

    2015-10-01

    The purity determination of organic calibration standards using the traditional mass balance approach is described. Demonstrated examples highlight the potential for bias in each measurement and the need to implement an approach that provides a cross-check for each result, affording fit for purpose purity values in a timely and cost-effective manner. Chromatographic techniques such as gas chromatography with flame ionisation detection (GC-FID) and high-performance liquid chromatography with UV detection (HPLC-UV), combined with mass and NMR spectroscopy, provide a detailed impurity profile allowing an efficient conversion of chromatographic peak areas into relative mass fractions, generally avoiding the need to calibrate each impurity present. For samples analysed by GC-FID, a conservative measurement uncertainty budget is described, including a component to cover potential variations in the response of each unidentified impurity. An alternative approach is also detailed in which extensive purification eliminates the detector response factor issue, facilitating the certification of a super-pure calibration standard which can be used to quantify the main component in less-pure candidate materials. This latter approach is particularly useful when applying HPLC analysis with UV detection. Key to the success of this approach is the application of both qualitative and quantitative (1)H NMR spectroscopy.

  10. Techniques for Improving Cash Management.

    ERIC Educational Resources Information Center

    Lykins, Ronald G.

    1973-01-01

    This article deals with several techniques for regulating cash inflow and outflow and investing surplus cash for short periods of time. The techniques are: (1) consolidating checking accounts, (2) determining surplus cash by examining bank balances in conjunction with the cash book, (3) selecting a minimum bank balance, (4) investing a greater…

  11. Eddy Current Rail Inspection Using AC Bridge Techniques.

    PubMed

    Liu, Ze; Koffman, Andrew D; Waltrip, Bryan C; Wang, Yicheng

    2013-01-01

    AC bridge techniques commonly used for precision impedance measurements have been adapted to develop an eddy current sensor for rail defect detection. By using two detection coils instead of just one as in a conventional sensor, we can balance out the large baseline signals corresponding to a normal rail. We have significantly enhanced the detection sensitivity of the eddy current method by detecting and demodulating the differential signal of the two coils induced by rail defects, using a digital lock-in amplifier algorithm. We have also explored compensating for the lift-off effect of the eddy current sensor due to vibrations by using the summing signal of the detection coils to measure the lift-off distance. The dominant component of the summing signal is a constant resulting from direct coupling from the excitation coil, which can be experimentally determined. The remainder of the summing signal, which decreases as the lift-off distance increases, is induced by the secondary eddy current. This dependence on the lift-off distance is used to calibrate the differential signal, allowing for a more accurate characterization of the defects. Simulated experiments on a sample rail have been performed using a computer controlled X-Y moving table with the X-axis mimicking the train's motion and the Y-axis mimicking the train's vibrational bumping. Experimental results demonstrate the effectiveness of the new detection method.

  12. Balance Contrast Enhancement using piecewise linear stretching

    NASA Astrophysics Data System (ADS)

    Rahavan, R. V.; Govil, R. C.

    1993-04-01

    Balance Contrast Enhancement is one of the techniques employed to produce color composites with increased color contrast. It equalizes the three images used for color composition in range and mean. This results in a color composite with large variation in hue. Here, it is shown that piecewise linear stretching can be used for performing the Balance Contrast Enhancement. In comparison with the Balance Contrast Enhancement Technique using parabolic segment as transfer function (BCETP), the method presented here is algorithmically simple, constraint-free and produces comparable results.

  13. Dynamic sample size detection in learning command line sequence for continuous authentication.

    PubMed

    Traore, Issa; Woungang, Isaac; Nakkabi, Youssef; Obaidat, Mohammad S; Ahmed, Ahmed Awad E; Khalilian, Bijan

    2012-10-01

    Continuous authentication (CA) consists of authenticating the user repetitively throughout a session with the goal of detecting and protecting against session hijacking attacks. While the accuracy of the detector is central to the success of CA, the detection delay or length of an individual authentication period is important as well since it is a measure of the window of vulnerability of the system. However, high accuracy and small detection delay are conflicting requirements that need to be balanced for optimum detection. In this paper, we propose the use of sequential sampling technique to achieve optimum detection by trading off adequately between detection delay and accuracy in the CA process. We illustrate our approach through CA based on user command line sequence and naïve Bayes classification scheme. Experimental evaluation using the Greenberg data set yields encouraging results consisting of a false acceptance rate (FAR) of 11.78% and a false rejection rate (FRR) of 1.33%, with an average command sequence length (i.e., detection delay) of 37 commands. When using the Schonlau (SEA) data set, we obtain FAR = 4.28% and FRR = 12%.

  14. 78 FR 17300 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-21

    ... balance land for cracks. Since we issued that AD, a crack was detected in a Trent 500 IP compressor rotor shaft rear balance land during a shop visit, and further engineering evaluation done by RR concluded... AD to detect cracking on the IP compressor rotor shaft rear balance land, which could lead to...

  15. Rapid Pupil-Based Assessment of Glaucomatous Damage

    PubMed Central

    Chen, Yanjun; Wyatt, Harry J.; Swanson, William H.; Dul, Mitchell W.

    2010-01-01

    Purpose To investigate the ability of a technique employing pupillometry and functionally-shaped stimuli to assess loss of visual function due to glaucomatous optic neuropathy. Methods Pairs of large stimuli, mirror images about the horizontal meridian, were displayed alternately in the upper and lower visual field. Pupil diameter was recorded and analyzed in terms of the “contrast balance” (relative sensitivity to the upper and lower stimuli), and the pupil constriction amplitude to upper and lower stimuli separately. A group of 40 patients with glaucoma was tested twice in a first session, and twice more in a second session, 1 to 3 weeks later. A group of 40 normal subjects was tested with the same protocol. Results Results for the normal subjects indicated functional symmetry in upper/lower retina, on average. Contrast balance results for the patients with glaucoma differed from normal: half the normal subjects had contrast balance within 0.06 log unit of equality and 80% had contrast balance within 0.1 log unit. Half the patients had contrast balances more than 0.1 log unit from equality. Patient contrast balances were moderately correlated with predictions from perimetric data (r = 0.37, p < 0.00001). Contrast balances correctly classified visual field damage in 28 patients (70%), and response amplitudes correctly classified 24 patients (60%). When contrast balance and response amplitude were combined, receiver operating characteristic area for discriminating glaucoma from normal was 0.83. Conclusions Pupillary evaluation of retinal asymmetry provides a rapid method for detecting and classifying visual field defects. In this patient population, classification agreed with perimetry in 70% of eyes. PMID:18521026

  16. Supercontinuum Fourier transform spectrometry with balanced detection on a single photodiode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goncharov, Vasily V.; Hall, Gregory E., E-mail: gehall@bnl.gov

    We demonstrate a method of combining a supercontinuum light source with a commercial Fourier transform spectrometer, using a novel approach to dual-beam balanced detection, implemented with phase-sensitive detection on a single light detector. A 40 dB reduction in the relative intensity noise is achieved for broadband light, analogous to conventional balanced detection methods using two matched photodetectors. Unlike conventional balanced detection, however, this method exploits the time structure of the broadband source to interleave signal and reference pulse trains in the time domain, recording the broadband differential signal at the fundamental pulse repetition frequency of the supercontinuum. The method ismore » capable of real-time correction for instability in the supercontinuum spectral structure over a broad range of wavelengths and is compatible with commercially designed spectrometers. A proof-of-principle experimental setup is demonstrated for weak absorption in the 1500-1600 nm region.« less

  17. Is it possible to re-establish pre-operative patellar kinematics using a ligament-balanced technique in total knee arthroplasty? A cadaveric investigation.

    PubMed

    Keshmiri, Armin; Springorum, Hans; Baier, Clemens; Zeman, Florian; Grifka, Joachim; Maderbacher, Günther

    2015-03-01

    Several authors emphasise that the appearance of patellar maltracking after total knee arthroplasty (TKA) is caused by rotational malalignment of the femoral and tibial components. Ligament-balanced femoral component rotation was not found to be associated with abnormal postoperative patellar position. We hypothesised that a ligament-balanced technique in TKA has the ability to best re-establish patellar kinematics. In ten cadaveric knees TKA was performed assessing femoral rotation in ligament-balanced and different femoral and tibial component rotation alignments. Patellar kinematics after different component rotations were analysed using a commercial computer navigation system. Ligament-balanced femoral rotation showed the best re-establishment of patellar kinematics after TKA compared to the healthy pre-operative knee. In contrast to tibial component rotation, femoral component rotation had a major impact on patellofemoral kinematics. This investigation suggests that a ligament-balanced technique in TKA is most likely to re-establish natural patellofemoral kinematics. Tibial component rotation did not influence patellar kinematics.

  18. Precise and long-term stabilization of the carrier-envelope phase of femtosecond laser pulses using an enhanced direct locking technique.

    PubMed

    Yu, Tae Jun; Hong, Kyung-Han; Choi, Hyun-Gyug; Sung, Jae Hee; Choi, Il Woo; Ko, Do-Kyeong; Lee, Jongmin; Kim, Junwon; Kim, Dong Eon; Nam, Chang Hee

    2007-06-25

    We demonstrate a long-term operation with reduced phase noise in the carrier-envelope-phase (CEP) stabilization process by employing a double feedback loop and an improved signal detection in the direct locking technique [Opt. Express 13, 2969 (2005)]. A homodyne balanced detection method is employed for efficiently suppressing the dc noise in the f-2f beat signal, which is converted into the CEP noise in the direct locking loop working at around zero carrier-envelope offset frequency (f(ceo)). In order to enhance the long-term stability, we have used the double feedback scheme that modulates both the oscillator pump power for a fast control and the intracavity-prism insertion depth for a slow and high-dynamic-range control. As a result, the in-loop phase jitter is reduced from 50 mrad of the previous result to 29 mrad, corresponding to 13 as in time scale, and the long-term stable operation is achieved for more than 12 hours.

  19. Neonatal Jaundice Detection System.

    PubMed

    Aydın, Mustafa; Hardalaç, Fırat; Ural, Berkan; Karap, Serhat

    2016-07-01

    Neonatal jaundice is a common condition that occurs in newborn infants in the first week of life. Today, techniques used for detection are required blood samples and other clinical testing with special equipment. The aim of this study is creating a non-invasive system to control and to detect the jaundice periodically and helping doctors for early diagnosis. In this work, first, a patient group which is consisted from jaundiced babies and a control group which is consisted from healthy babies are prepared, then between 24 and 48 h after birth, 40 jaundiced and 40 healthy newborns are chosen. Second, advanced image processing techniques are used on the images which are taken with a standard smartphone and the color calibration card. Segmentation, pixel similarity and white balancing methods are used as image processing techniques and RGB values and pixels' important information are obtained exactly. Third, during feature extraction stage, with using colormap transformations and feature calculation, comparisons are done in RGB plane between color change values and the 8-color calibration card which is specially designed. Finally, in the bilirubin level estimation stage, kNN and SVR machine learning regressions are used on the dataset which are obtained from feature extraction. At the end of the process, when the control group is based on for comparisons, jaundice is succesfully detected for 40 jaundiced infants and the success rate is 85 %. Obtained bilirubin estimation results are consisted with bilirubin results which are obtained from the standard blood test and the compliance rate is 85 %.

  20. Digitally balanced detection for optical tomography.

    PubMed

    Hafiz, Rehan; Ozanyan, Krikor B

    2007-10-01

    Analog balanced Photodetection has found extensive usage for sensing of a weak absorption signal buried in laser intensity noise. This paper proposes schemes for compact, affordable, and flexible digital implementation of the already established analog balanced detection, as part of a multichannel digital tomography system. Variants of digitally balanced detection (DBD) schemes, suitable for weak signals on a largely varying background or weakly varying envelopes of high frequency carrier waves, are introduced analytically and elaborated in terms of algorithmic and hardware flow. The DBD algorithms are implemented on a low-cost general purpose reconfigurable hardware (field-programmable gate array), utilizing less than half of its resources. The performance of the DBD schemes compare favorably with their analog counterpart: A common mode rejection ratio of 50 dB was observed over a bandwidth of 300 kHz, limited mainly by the host digital hardware. The close relationship between the DBD outputs and those of known analog balancing circuits is discussed in principle and shown experimentally in the example case of propane gas detection.

  1. Consideration of Dynamical Balances

    NASA Technical Reports Server (NTRS)

    Errico, Ronald M.

    2015-01-01

    The quasi-balance of extra-tropical tropospheric dynamics is a fundamental aspect of nature. If an atmospheric analysis does not reflect such balance sufficiently well, the subsequent forecast will exhibit unrealistic behavior associated with spurious fast-propagating gravity waves. Even if these eventually damp, they can create poor background fields for a subsequent analysis or interact with moist physics to create spurious precipitation. The nature of this problem will be described along with the reasons for atmospheric balance and techniques for mitigating imbalances. Attention will be focused on fundamental issues rather than on recipes for various techniques.

  2. Basic principles of fluorescence detection with use of 5-ALA

    NASA Astrophysics Data System (ADS)

    Baumgartner, Reinhold; Stepp, Herbert G.

    2000-06-01

    5-Aminolevulinic acid (5-ALA) has been proven to induce selective accumulation of flourescent Protoporphyrin IX (PPIX) in many types of malignant tissue. According to the target to treatment different routes of topical and systemical application of 5-ALA can be chosen. They include techniques like inhalation, installation and rinsing. For fluorescence detection a lamp based system have been developed in the laser-Forschungslabor in Munich together with Storz company. By skillful balancing of excitation filter centered around 400 nm and the observation filter with transmission above 450 nm images with high color contrast can be obtained. The universal application of the D-LIGHT could be demonstrated in different clinical disciplines like urology, neurosurgery, ENT clinic, gynecology and others.

  3. Coaching for Balance.

    ERIC Educational Resources Information Center

    Larson, Bonnie

    2001-01-01

    Discusses coaching for balance the integration of the whole self: physical (body), intellectual (mind), spiritual (soul), and emotional (heart). Offers four ways to identify problems and tell whether someone is out of balance and four coaching techniques for creating balance. (Contains 11 references.) (JOW)

  4. Detection and Use of Load and Gage Output Repeats of Wind Tunnel Strain-Gage Balance Data

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.

    2017-01-01

    Criteria are discussed that may be used for the detection of load and gage output repeats of wind tunnel strain-gage balance data. First, empirical thresholds are introduced that help determine if the loads or electrical outputs of a pair of balance calibration or check load data points match. A threshold of 0.01 percent of the load capacity is suggested for the identification of matching loads. Similarly, a threshold of 0.1 microV/V is recommended for the identification of matching electrical outputs. Two examples for the use of load and output repeats are discussed to illustrate benefits of the implementation of a repeat point detection algorithm in a balance data analysis software package. The first example uses the suggested load threshold to identify repeat data points that may be used to compute pure errors of the balance loads. This type of analysis may reveal hidden data quality issues that could potentially be avoided by making calibration process improvements. The second example uses the electrical output threshold for the identification of balance fouling. Data from the calibration of a six-component force balance is used to illustrate the calculation of the pure error of the balance loads.

  5. Spectral domain optical coherence tomography with dual-balanced detection

    NASA Astrophysics Data System (ADS)

    Bo, En; Liu, Xinyu; Chen, Si; Luo, Yuemei; Wang, Nanshuo; Wang, Xianghong; Liu, Linbo

    2016-03-01

    We developed a spectral domain optical coherence tomography (SD-OCT) system employing dual-balanced detection (DBD) for direct current term suppression and SNR enhancement, especially for auto-autocorrelation artifacts reduction. The DBD was achieved by using a beam splitter to building a free-space Michelson interferometer, which generated two interferometric spectra with a phase difference of π. These two phase-opposed spectra were guided to the spectrometer through two single mode fibers of the 8 fiber v-groove array and acquired by ultizing the upper two lines of a three-line CCD camera. We rotated this fiber v-groove array by 1.35 degrees to focus two spectra onto the first and second line of the CCD camera. Two spectra were aligned by optimum spectrum matching algorithm. By subtracting one spectrum from the other, this dual-balanced detection system achieved a direct current term suppression of ~30 dB, SNR enhancement of ~3 dB, and auto-autocorrelation artifacts reduction of ~10 dB experimentally. Finally we respectively validated the feasibility and performance of dual-balanced detection by imaging a glass plate and swine corneal tissue ex vivo. The quality of images obtained using dual-balanced detection was significantly improved with regard to the conventional single-detection (SD) images.

  6. Class imbalance in unsupervised change detection - A diagnostic analysis from urban remote sensing

    NASA Astrophysics Data System (ADS)

    Leichtle, Tobias; Geiß, Christian; Lakes, Tobia; Taubenböck, Hannes

    2017-08-01

    Automatic monitoring of changes on the Earth's surface is an intrinsic capability and simultaneously a persistent methodological challenge in remote sensing, especially regarding imagery with very-high spatial resolution (VHR) and complex urban environments. In order to enable a high level of automatization, the change detection problem is solved in an unsupervised way to alleviate efforts associated with collection of properly encoded prior knowledge. In this context, this paper systematically investigates the nature and effects of class distribution and class imbalance in an unsupervised binary change detection application based on VHR imagery over urban areas. For this purpose, a diagnostic framework for sensitivity analysis of a large range of possible degrees of class imbalance is presented, which is of particular importance with respect to unsupervised approaches where the content of images and thus the occurrence and the distribution of classes are generally unknown a priori. Furthermore, this framework can serve as a general technique to evaluate model transferability in any two-class classification problem. The applied change detection approach is based on object-based difference features calculated from VHR imagery and subsequent unsupervised two-class clustering using k-means, genetic k-means and self-organizing map (SOM) clustering. The results from two test sites with different structural characteristics of the built environment demonstrated that classification performance is generally worse in imbalanced class distribution settings while best results were reached in balanced or close to balanced situations. Regarding suitable accuracy measures for evaluating model performance in imbalanced settings, this study revealed that the Kappa statistics show significant response to class distribution while the true skill statistic was widely insensitive to imbalanced classes. In general, the genetic k-means clustering algorithm achieved the most robust results with respect to class imbalance while the SOM clustering exhibited a distinct optimization towards a balanced distribution of classes.

  7. Detection and characterization of elongated bubbles and drops in two-phase flow using magnetic fields

    NASA Astrophysics Data System (ADS)

    Wiederhold, A.; Boeck, T.; Resagk, C.

    2017-08-01

    We report a method to detect and to measure the size and velocity of elongated bubbles or drops in a dispersed two-phase flow. The difference of the magnetic susceptibilities between two phases causes a force on the interface between both phases when it is exposed to an external magnetic field. The force is measured with a state-of-the-art electromagnetic compensation balance. While the front and the back of the bubble pass the magnetic field, two peaks in the force signal appear, which can be used to calculate the velocity and geometry parameters of the bubble. We achieve a substantial advantage over other bubble detection techniques because this technique is contactless, non-invasive, independent of the electrical conductivity and can be applied to opaque or aggressive fluids. The measurements are performed in an inclined channel with air bubbles and paraffin oil drops in water. The bubble length is in the range of 0.1-0.25 m and the bubble velocity lies between 0.02-0.22 m s-1. Furthermore we show that it is possible to apply this measurement principle for nondestructive testing (NDT) of diamagnetic and paramagnetic materials like metal, plastics or glass, provided that defects are in the range of 10‒2 m. This technique opens up new possibilities in industrial applications to measure two-phase flow parameters and in material testing.

  8. Balanced detection for self-mixing interferometry.

    PubMed

    Li, Kun; Cavedo, Federico; Pesatori, Alessandro; Zhao, Changming; Norgia, Michele

    2017-01-15

    We propose a new detection scheme for self-mixing interferometry using two photodiodes for implementing a differential acquisition. The method is based on the phase opposition of the self-mixing signal measured between the two laser diode facet outputs. The subtraction of the two outputs implements a sort of balanced detection that improves the signal quality, and allows canceling of unwanted signals due to laser modulation and disturbances on laser supply and transimpedance amplifier. Experimental results demonstrate the benefits of differential acquisition in a system for both absolute distance and displacement-vibration measurement. This Letter provides guidance for the design of self-mixing interferometers using balanced detection.

  9. Development of references of anomalies detection on P91 material using Self-Magnetic Leakage Field (SMLF) technique

    NASA Astrophysics Data System (ADS)

    Husin, Shuib; Afiq Pauzi, Ahmad; Yunus, Salmi Mohd; Ghafar, Mohd Hafiz Abdul; Adilin Sekari, Saiful

    2017-10-01

    This technical paper demonstrates the successful of the application of self-magnetic leakage field (SMLF) technique in detecting anomalies in weldment of a thick P91 materials joint (1 inch thickness). Boiler components such as boiler tubes, stub boiler at penthouse and energy piping such as hot reheat pipe (HRP) and H-balance energy piping to turbine are made of P91 material. P91 is ferromagnetic material, therefore the technique of self-magnetic leakage field (SMLF) is applicable for P91 in detecting anomalies within material (internal defects). The technique is categorized under non-destructive technique (NDT). It is the second passive method after acoustic emission (AE), at which the information on structures radiation (magnetic field and energy waves) is used. The measured magnetic leakage field of a product or component is a magnetic leakage field occurring on the component’s surface in the zone of dislocation stable slipbands under the influence of operational (in-service) or residual stresses or in zones of maximum inhomogeneity of metal structure in new products or components. Inter-granular and trans-granular cracks, inclusion, void, cavity and corrosion are considered types of inhomogeneity and discontinuity in material where obviously the output of magnetic leakage field will be shown when using this technique. The technique does not required surface preparation for the component to be inspected. This technique is contact-type inspection, which means the sensor has to touch or in-contact to the component’s surface during inspection. The results of application of SMLF technique on the developed P91 reference blocks have demonstrated that the technique is practical to be used for anomaly inspection and detection as well as identification of anomalies’ location. The evaluation of this passive self-magnetic leakage field (SMLF) technique has been verified by other conventional non-destructive tests (NDTs) on the reference blocks where simulated defects/anomalies have been developed inside at the weldment. The results from the inspection test showed that the signatures of magnetic leakage field gradient distribution prove that the peak is found on the location of defect/anomaly in the reference block. It is in agreement with the evidence of anomaly that seen in the radiography test film (RT).

  10. Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

    NASA Technical Reports Server (NTRS)

    Bloomberg, Jacob; Reschke, Millard; Mulavara, Ajitkumar; Wood, Scott; Serrador, Jorge; Fiedler, Matthew; Kofman, Igor; Peters, Brian T.; Cohen, Helen

    2012-01-01

    Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/ sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain s ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable providing imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles.

  11. Computational imaging with a balanced detector.

    PubMed

    Soldevila, F; Clemente, P; Tajahuerce, E; Uribe-Patarroyo, N; Andrés, P; Lancis, J

    2016-06-29

    Single-pixel cameras allow to obtain images in a wide range of challenging scenarios, including broad regions of the electromagnetic spectrum and through scattering media. However, there still exist several drawbacks that single-pixel architectures must address, such as acquisition speed and imaging in the presence of ambient light. In this work we introduce balanced detection in combination with simultaneous complementary illumination in a single-pixel camera. This approach enables to acquire information even when the power of the parasite signal is higher than the signal itself. Furthermore, this novel detection scheme increases both the frame rate and the signal-to-noise ratio of the system. By means of a fast digital micromirror device together with a low numerical aperture collecting system, we are able to produce a live-feed video with a resolution of 64 × 64 pixels at 5 Hz. With advanced undersampling techniques, such as compressive sensing, we can acquire information at rates of 25 Hz. By using this strategy, we foresee real-time biological imaging with large area detectors in conditions where array sensors are unable to operate properly, such as infrared imaging and dealing with objects embedded in turbid media.

  12. Computational imaging with a balanced detector

    NASA Astrophysics Data System (ADS)

    Soldevila, F.; Clemente, P.; Tajahuerce, E.; Uribe-Patarroyo, N.; Andrés, P.; Lancis, J.

    2016-06-01

    Single-pixel cameras allow to obtain images in a wide range of challenging scenarios, including broad regions of the electromagnetic spectrum and through scattering media. However, there still exist several drawbacks that single-pixel architectures must address, such as acquisition speed and imaging in the presence of ambient light. In this work we introduce balanced detection in combination with simultaneous complementary illumination in a single-pixel camera. This approach enables to acquire information even when the power of the parasite signal is higher than the signal itself. Furthermore, this novel detection scheme increases both the frame rate and the signal-to-noise ratio of the system. By means of a fast digital micromirror device together with a low numerical aperture collecting system, we are able to produce a live-feed video with a resolution of 64 × 64 pixels at 5 Hz. With advanced undersampling techniques, such as compressive sensing, we can acquire information at rates of 25 Hz. By using this strategy, we foresee real-time biological imaging with large area detectors in conditions where array sensors are unable to operate properly, such as infrared imaging and dealing with objects embedded in turbid media.

  13. Computational imaging with a balanced detector

    PubMed Central

    Soldevila, F.; Clemente, P.; Tajahuerce, E.; Uribe-Patarroyo, N.; Andrés, P.; Lancis, J.

    2016-01-01

    Single-pixel cameras allow to obtain images in a wide range of challenging scenarios, including broad regions of the electromagnetic spectrum and through scattering media. However, there still exist several drawbacks that single-pixel architectures must address, such as acquisition speed and imaging in the presence of ambient light. In this work we introduce balanced detection in combination with simultaneous complementary illumination in a single-pixel camera. This approach enables to acquire information even when the power of the parasite signal is higher than the signal itself. Furthermore, this novel detection scheme increases both the frame rate and the signal-to-noise ratio of the system. By means of a fast digital micromirror device together with a low numerical aperture collecting system, we are able to produce a live-feed video with a resolution of 64 × 64 pixels at 5 Hz. With advanced undersampling techniques, such as compressive sensing, we can acquire information at rates of 25 Hz. By using this strategy, we foresee real-time biological imaging with large area detectors in conditions where array sensors are unable to operate properly, such as infrared imaging and dealing with objects embedded in turbid media. PMID:27353733

  14. A ppb level sensitive sensor for atmospheric methane detection

    NASA Astrophysics Data System (ADS)

    Xia, Jinbao; Zhu, Feng; Zhang, Sasa; Kolomenskii, Alexandre; Schuessler, Hans

    2017-11-01

    A high sensitivity sensor, combining a multipass cell and wavelength modulation spectroscopy in the near infrared spectral region was designed and implemented for trace gas detection. The effective length of the multipass cell was about 290 meters. The developed spectroscopic technique demonstrates an improved sensitivity of methane in ambient air and a relatively short detection time compared to previously reported sensors. Home-built electronics and software were employed for diode laser frequency modulation, signal lock-in detection and processing. A dual beam scheme and a balanced photo-detector were implemented to suppress the intensity modulation and noise for better detection sensitivity. The performance of the sensor was evaluated in a series of measurements ranging from three hours to two days. The average methane concentration measured in ambient air was 2.01 ppm with a relative error of ± 2.5%. With Allan deviation analysis, it was found that the methane detection limit of 1.2 ppb was achieved in 650 s. The developed sensor is compact and portable, and thus it is well suited for field measurements of methane and other trace gases.

  15. Observation of Squeezed Light in the 2 μ m Region

    NASA Astrophysics Data System (ADS)

    Mansell, Georgia L.; McRae, Terry G.; Altin, Paul A.; Yap, Min Jet; Ward, Robert L.; Slagmolen, Bram J. J.; Shaddock, Daniel A.; McClelland, David E.

    2018-05-01

    We present the generation and detection of squeezed light in the 2 μ m wavelength region. This experiment is a crucial step in realizing the quantum noise reduction techniques that will be required for future generations of gravitational-wave detectors. Squeezed vacuum is generated via degenerate optical parametric oscillation from a periodically poled potassium titanyl phosphate crystal, in a dual resonant cavity. The experiment uses a frequency stabilized 1984 nm thulium fiber laser, and squeezing is detected using balanced homodyne detection with extended InGaAs photodiodes. We have measured 4.0 ±0.1 dB of squeezing and 10.5 ±0.5 dB of antisqueezing relative to the shot noise level in the audio frequency band, limited by photodiode quantum efficiency. The inferred squeezing level directly after the optical parametric oscillator, after accounting for known losses and phase noise, is 10.7 dB.

  16. Changes in muscle activation following balance and technique training and a season of Australian football.

    PubMed

    Donnelly, C J; Elliott, B C; Doyle, T L A; Finch, C F; Dempsey, A R; Lloyd, D G

    2015-05-01

    Determine if balance and technique training implemented adjunct to 1001 male Australian football players' training influenced the activation/strength of the muscles crossing the knee during pre-planned and unplanned sidestepping. Randomized Control Trial. Each Australian football player participated in either 28 weeks of balance and technique training or 'sham' training. Twenty-eight Australian football players (balance and technique training, n=12; 'sham' training, n=16) completed biomechanical testing pre-to-post training. Peak knee moments and directed co-contraction ratios in three degrees of freedom, as well as total muscle activation were calculated during pre-planned and unplanned sidestepping. No significant differences in muscle activation/strength were observed between the 'sham' training and balance and technique training groups. Following a season of Australian football, knee extensor (p=0.023) and semimembranosus (p=0.006) muscle activation increased during both pre-planned sidestepping and unplanned sidestepping. Following a season of Australian football, total muscle activation was 30% lower and peak valgus knee moments 80% greater (p=0.022) during unplanned sidestepping when compared with pre-planned sidestepping. When implemented in a community level training environment, balance and technique training was not effective in changing the activation of the muscles crossing the knee during sidestepping. Following a season of Australian football, players are better able to support both frontal and sagittal plane knee moments. When compared to pre-planned sidestepping, Australian football players may be at increased risk of anterior cruciate ligament injury during unplanned sidestepping in the latter half of an Australian football season. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Supporting clinician educators to achieve "work-work balance".

    PubMed

    Maniate, Jerry; Dath, Deepak; Cooke, Lara; Leslie, Karen; Snell, Linda; Busari, Jamiu

    2016-10-01

    Clinician Educators (CE) have numerous responsibilities in different professional domains, including clinical, education, research, and administration. Many CEs face tensions trying to manage these often competing professional responsibilities and achieve "work-work balance." Rich discussions of techniques for work-work balance amongst CEs at a medical education conference inspired the authors to gather, analyze, and summarize these techniques to share with others. In this paper we present the CE's "Four Ps"; these are practice points that support both the aspiring and established CE to help improve their performance and productivity as CEs, and allow them to approach work-work balance.

  18. Determine Optimal Stimulus Amplitude for Using Vestibular Stochastic Stimulation to Improve Balance Function

    NASA Technical Reports Server (NTRS)

    Goel, R.; Kofman, I.; DeDios, Y. E.; Jeevarajan, J.; Stepanyan, V.; Nair, M.; Congdon, S.; Fregia, M.; Cohen, H.; Bloomberg, J.J.; hide

    2015-01-01

    Sensorimotor changes such as postural and gait instabilities can affect the functional performance of astronauts when they transition across different gravity environments. We are developing a method, based on stochastic resonance (SR), to enhance information transfer by applying non-zero levels of external noise on the vestibular system (vestibular stochastic resonance, VSR). Our previous work has shown the advantageous effects of VSR in a balance task of standing on an unstable surface [1]. This technique to improve detection of vestibular signals uses a stimulus delivery system that provides imperceptibly low levels of white noise-based binaural bipolar electrical stimulation of the vestibular system. The goal of this project is to determine optimal levels of stimulation for SR applications by using a defined vestibular threshold of motion detection. A series of experiments were carried out to determine a robust paradigm to identify a vestibular threshold that can then be used to recommend optimal stimulation levels for sensorimotor adaptability (SA) training applications customized to each crewmember. The amplitude of stimulation to be used in the VSR application has varied across studies in the literature such as 60% of nociceptive stimulus thresholds [2]. We compared subjects' perceptual threshold with that obtained from two measures of body sway. Each test session was 463s long and consisted of several 15s long sinusoidal stimuli, at different current amplitudes (0-2 mA), interspersed with 20-20.5s periods of no stimulation. Subjects sat on a chair with their eyes closed and had to report their perception of motion through a joystick. A force plate underneath the chair recorded medio-lateral shear forces and roll moments. Comparison of threshold of motion detection obtained from joystick data versus body sway suggests that perceptual thresholds were significantly lower. In the balance task, subjects stood on an unstable surface and had to maintain balance, and the stimulation was administered from 20-400% of subjects' vestibular threshold. Optimal stimulation amplitude was determined at which the balance performance was best compared to control (no stimulation). Preliminary results show that, in general, using stimulation amplitudes at 40-60% of perceptual motion threshold significantly improved the balance performance. We hypothesize that VSR stimulation will act synergistically with SA training to improve adaptability by increasing utilization of vestibular information and therefore will help us to optimize and personalize a SA countermeasure prescription. This combination may help to significantly reduce the number of days required to recover functional performance to preflight levels after long-duration spaceflight.

  19. Optimized RNA ISH, RNA FISH and protein-RNA double labeling (IF/FISH) in Drosophila ovaries

    PubMed Central

    Zimmerman, Sandra G; Peters, Nathaniel C; Altaras, Ariel E; Berg, Celeste A

    2014-01-01

    In situ hybridization (ISH) is a powerful technique for detecting nucleic acids in cells and tissues. Here we describe three ISH procedures that are optimized for Drosophila ovaries: whole-mount, digoxigenin-labeled RNA ISH; RNA fluorescent ISH (FISH); and protein immunofluorescence (IF)–RNA FISH double labeling (IF/FISH). Each procedure balances conflicting requirements for permeabilization, fixation and preservation of antigenicity to detect RNA and protein expression with high resolution and sensitivity. The ISH protocol uses alkaline phosphatase–conjugated digoxigenin antibodies followed by a color reaction, whereas FISH detection involves tyramide signal amplification (TSA). To simultaneously preserve antigens for protein detection and enable RNA probe penetration for IF/FISH, we perform IF before FISH and use xylenes and detergents to permeabilize the tissue rather than proteinase K, which can damage the antigens. ISH and FISH take 3 d to perform, whereas IF/FISH takes 5 d. Probe generation takes 1 or 2 d to perform. PMID:24113787

  20. Towards a balanced software team formation based on Belbin team role using fuzzy technique

    NASA Astrophysics Data System (ADS)

    Omar, Mazni; Hasan, Bikhtiyar; Ahmad, Mazida; Yasin, Azman; Baharom, Fauziah; Mohd, Haslina; Darus, Norida Muhd

    2016-08-01

    In software engineering (SE), team roles play significant impact in determining the project success. To ensure the optimal outcome of the project the team is working on, it is essential to ensure that the team members are assigned to the right role with the right characteristics. One of the prevalent team roles is Belbin team role. A successful team must have a balance of team roles. Thus, this study demonstrates steps taken to determine balance of software team formation based on Belbin team role using fuzzy technique. Fuzzy technique was chosen because it allows analyzing of imprecise data and classifying selected criteria. In this study, two roles in Belbin team role, which are Shaper (Sh) and Plant (Pl) were chosen to assign the specific role in software team. Results show that the technique is able to be used for determining the balance of team roles. Future works will focus on the validation of the proposed method by using empirical data in industrial setting.

  1. The Automated Assessment of Postural Stability: Balance Detection Algorithm.

    PubMed

    Napoli, Alessandro; Glass, Stephen M; Tucker, Carole; Obeid, Iyad

    2017-12-01

    Impaired balance is a common indicator of mild traumatic brain injury, concussion and musculoskeletal injury. Given the clinical relevance of such injuries, especially in military settings, it is paramount to develop more accurate and reliable on-field evaluation tools. This work presents the design and implementation of the automated assessment of postural stability (AAPS) system, for on-field evaluations following concussion. The AAPS is a computer system, based on inexpensive off-the-shelf components and custom software, that aims to automatically and reliably evaluate balance deficits, by replicating a known on-field clinical test, namely, the Balance Error Scoring System (BESS). The AAPS main innovation is its balance error detection algorithm that has been designed to acquire data from a Microsoft Kinect ® sensor and convert them into clinically-relevant BESS scores, using the same detection criteria defined by the original BESS test. In order to assess the AAPS balance evaluation capability, a total of 15 healthy subjects (7 male, 8 female) were required to perform the BESS test, while simultaneously being tracked by a Kinect 2.0 sensor and a professional-grade motion capture system (Qualisys AB, Gothenburg, Sweden). High definition videos with BESS trials were scored off-line by three experienced observers for reference scores. AAPS performance was assessed by comparing the AAPS automated scores to those derived by three experienced observers. Our results show that the AAPS error detection algorithm presented here can accurately and precisely detect balance deficits with performance levels that are comparable to those of experienced medical personnel. Specifically, agreement levels between the AAPS algorithm and the human average BESS scores ranging between 87.9% (single-leg on foam) and 99.8% (double-leg on firm ground) were detected. Moreover, statistically significant differences in balance scores were not detected by an ANOVA test with alpha equal to 0.05. Despite some level of disagreement between human and AAPS-generated scores, the use of an automated system yields important advantages over currently available human-based alternatives. These results underscore the value of using the AAPS, that can be quickly deployed in the field and/or in outdoor settings with minimal set-up time. Finally, the AAPS can record multiple error types and their time course with extremely high temporal resolution. These features are not achievable by humans, who cannot keep track of multiple balance errors with such a high resolution. Together, these results suggest that computerized BESS calculation may provide more accurate and consistent measures of balance than those derived from human experts.

  2. An evaluation of the carbon balance technique for estimating emission factors and fuel consumption in forest fires

    Treesearch

    Nelson, Jr. Ralph M.

    1982-01-01

    Eighteen experimental fires were used to compare measured and calculated values for emission factors and fuel consumption to evaluate the carbon balance technique. The technique is based on a model for the emission factor of carbon dioxide, corrected for the production of other emissions, and which requires measurements of effluent concentrations and air volume in the...

  3. Identification of the contribution of the ankle and hip joints to multi-segmental balance control

    PubMed Central

    2013-01-01

    Background Human stance involves multiple segments, including the legs and trunk, and requires coordinated actions of both. A novel method was developed that reliably estimates the contribution of the left and right leg (i.e., the ankle and hip joints) to the balance control of individual subjects. Methods The method was evaluated using simulations of a double-inverted pendulum model and the applicability was demonstrated with an experiment with seven healthy and one Parkinsonian participant. Model simulations indicated that two perturbations are required to reliably estimate the dynamics of a double-inverted pendulum balance control system. In the experiment, two multisine perturbation signals were applied simultaneously. The balance control system dynamic behaviour of the participants was estimated by Frequency Response Functions (FRFs), which relate ankle and hip joint angles to joint torques, using a multivariate closed-loop system identification technique. Results In the model simulations, the FRFs were reliably estimated, also in the presence of realistic levels of noise. In the experiment, the participants responded consistently to the perturbations, indicated by low noise-to-signal ratios of the ankle angle (0.24), hip angle (0.28), ankle torque (0.07), and hip torque (0.33). The developed method could detect that the Parkinson patient controlled his balance asymmetrically, that is, the right ankle and hip joints produced more corrective torque. Conclusion The method allows for a reliable estimate of the multisegmental feedback mechanism that stabilizes stance, of individual participants and of separate legs. PMID:23433148

  4. The Balanced Reading Program: Helping All Students Achieve Success.

    ERIC Educational Resources Information Center

    Blair-Larsen, Susan M., Ed.; Williams, Kathryn A., Ed.

    This book explains the methodologies, techniques, strategies, and knowledge base necessary to achieve a balanced reading program. The book's contributors define the key elements in a balanced reading program and provide guidelines for implementing a balanced instructional program in the classroom. Following an introduction which addresses…

  5. Using Analytical Techniques to Interpret Financial Statements.

    ERIC Educational Resources Information Center

    Walters, Donald L.

    1986-01-01

    Summarizes techniques for interpreting the balance sheet and the statement of revenues, expenditures, and changes-in-fund-balance sections of the comprehensive annual financial report required of all school districts. Uses three tables to show intricacies involved and focuses on analyzing favorable and unfavorable budget variances. (MLH)

  6. Age-related differences in quality of standing balance using a composite score.

    PubMed

    Pasma, Jantsje H; Bijlsma, Astrid Y; van der Bij, Mark D W; Arendzen, J Hans; Meskers, Carel G M; Maier, Andrea B

    2014-01-01

    Age-related differences in standing balance are not detected by testing the ability to maintain balance. Quality of standing balance might be more sensitive to detect age-related differences. To study age-related differences in quality of standing balance, center of pressure (CoP) movement was evaluated using a wide range of CoP parameters in several standing conditions in healthy young and old participants. In 35 healthy young (18-30 years) and 75 healthy old (70-80 years) participants, CoP movement was assessed in eight standing conditions on a force plate, including side-by-side, one-leg, semi-tandem and tandem stance, both with eyes open and eyes closed. Direction-specific CoP composite scores were calculated from standardized single CoP parameters (mean amplitude, amplitude variability, mean velocity, velocity variability and range) in anterior-posterior (AP) and medial-lateral (ML) direction. Linear regression analysis was used to detect age-related differences in single CoP parameters and composite scores - adjusted for gender, height and weight. Overall, single CoP parameters were higher in old compared to young participants, but no single CoP parameter consistently demonstrated the largest effect size for all standing conditions. Age-related differences were demonstrated for CoP composite scores in AP direction (tandem eyes open; semi-tandem eyes closed; p < 0.001). CoP composite scores in ML direction were consistently higher for all standing conditions in old compared to young participants (p < 0.001). CoP composite scores in ML direction were the most consistent parameters to detect age-related differences in quality of standing balance in healthy participants and might be of clinical value to detect subtle changes in quality of standing balance. © 2014 S. Karger AG, Basel

  7. Accounting: Teaching the Worksheet: The "What,""Why," and "How."

    ERIC Educational Resources Information Center

    Simpson, Kawanna J.; Musselman, Donald

    1979-01-01

    Techniques to enable accounting teachers to present the accounting worksheet are given, with examples of worksheet columns for income statement, balance sheet, revenue and expense, owner's equity, trial balance, and adjustments. The techniques also show the student the reasons (why) for and the mechanics (how) of the worksheet. (MF)

  8. Rotary-Balance Testing for Aircraft Dynamics (Les Essais sur Balance Rotative pour l’Etude de la Dynamique du Vol de l’Avion)

    DTIC Science & Technology

    1990-01-01

    critical examination of the rotary-balance techniques used in the AGARD community for the analysis of high-angle-of-attack dynamic behavior of aircraft. It...aircraft. It was felt that sudi a critical examination should encompass both the experimental techniques used to obtain rotary-flow aerodynamic data and the...monitor the vibrational and critical structural characteristies of the apparatus and tunnel support system. Many of these systems are integrated directly

  9. Examination of the perceived agility and balance during a reactive agility task.

    PubMed

    Stirling, Leia; Eke, Chika; Cain, Stephen M

    2018-01-01

    In vehicle dynamics, it is commonly understood that there is an inverse relationship between stability and maneuverability. However, animal studies have found that stability and maneuverability can coincide. In this study, we examine humans running a reactive agility obstacle and consider the relationship between observational perceived agility and balance, as well as the relationship between quantified surrogates of agility and balance. Recreational athletes (n = 18) completed the agility task while wearing inertial measurement units (IMUs) on their body. The task was also video-recorded. An observational study was completed by a separate group of adults (n = 33) that were asked to view the videos and score each athlete on a Likert scale for balance and for agility. The data from the body-worn IMUs were used to estimate quantified surrogate measures for agility and balance, and to assess if the relationship between the quantified agility and balance was in the same direction as the perceived relationship from the Likert scale responses. Results indicate that athletes that were given a higher Likert agility score were also given a higher balance score (rs = 0.75,p < 0.001). Quantitative surrogates of agility and balance also showed this same relationship. Additional insights on technique for this reactive agility task were informed by the quantitative surrogates. We observed the importance of stepping technique in achieving the faster completion times. The fast performing athletes spent a greater proportion of the task in double support and lower overall time in single support indicating increased periods of static stability. The fast performing athletes did not have a higher body speed, but performed the task with a more efficient technique, using foot placement to enable heading changes, and thus may have had a more efficient path. Similar to animal studies, people use technique to enable agile strategies while also enabling increased balance across the task.

  10. Report on Concepts & Approaches for SSBD for eCHEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, Chantell Lynne-Marie

    The verification of special nuclear material (SNM) in spent fuel pyroprocessing is an important safeguards challenge. The detection of spontaneous fission (SF) neutrons from curium is an accepted, non-destructive technique that has been applied to verify special nuclear material (SNM) content in used fuel and other materials in the fuel cycle. The nuclear material accounting (NMA) technique at the Korea Atomic Energy Research Institute’s Reference Engineering-scale Pyroprocessing Facility (REPF) is based on the Cm balance technique. Several publications have demonstrated the safeguards benefit from using process monitoring (PM) on nuclear facilities as a complementary measure to NMA. More recently, thismore » concept was expanded and preliminarily demonstrated for pyroprocessing. The concept of Signature Based Safeguards (SBS) is part of this expansion, and is built around the interpretation of input from various sensors in a declared facility coupled with complementary NMA methods to increase confidence and lower standard error inventory differences (SEID). The SBS methodology was conceptually developed and relies on near real time analysis of process monitoring data to detect material diversion complemented by robust containment and surveillance (C/S) measures. This work demonstrates one example of how the SBS framework can be used in the electrorefiner. In this SBS application, a combination of cyclic voltammetry (CV) and neutron counting is applied to track and monitor Pu mass balance. The main purpose of this experiment is to determine if meaningful information can be gained from CV measurements with regard to the Mg/Gd ratio. This data will be coupled with ICP-MS to verify Gd concentrations and analyzed for statistical significance. It is expected the CV data will register a significant change under the off-normal operating conditions. Knowing how to identify and interpret those changes may help inform how to target more traditional neutron counting methods, which could support a more efficient safeguards system. The experimental results will be compared with theoretical calculations and the ERAD simulations.« less

  11. Nuclear Weak Rates and Detailed Balance in Stellar Conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Misch, G. Wendell, E-mail: wendell@sjtu.edu, E-mail: wendell.misch@gmail.com

    Detailed balance is often invoked in discussions of nuclear weak transitions in astrophysical environments. Satisfaction of detailed balance is rightly touted as a virtue of some methods of computing nuclear transition strengths, but I argue that it need not necessarily be strictly obeyed in astrophysical environments, especially when the environment is far from weak equilibrium. I present the results of shell model calculations of nuclear weak strengths in both charged-current and neutral-current channels at astrophysical temperatures, finding some violation of detailed balance. I show that a slight modification of the technique to strictly obey detailed balance has little effect onmore » the reaction rates associated with these strengths under most conditions, though at high temperature the modified technique in fact misses some important strength. I comment on the relationship between detailed balance and weak equilibrium in astrophysical conditions.« less

  12. Real-time terahertz near-field microscope.

    PubMed

    Blanchard, F; Doi, A; Tanaka, T; Hirori, H; Tanaka, H; Kadoya, Y; Tanaka, K

    2011-04-25

    We report a terahertz near-field microscope with a high dynamic range that can capture images of a 370 x 740 μm2 area at 35 frames per second. We achieve high spatial resolution (14 μm corresponding to λ/30 for a center frequency at 0.7 THz) on a large area by combining two novel techniques: terahertz generation by tilted-pulse-front excitation and electro-optic balanced imaging detection using a thin crystal. To demonstrate the microscope capability, we reveal the field enhancement at the gap position of a dipole antenna after the irradiation of a terahertz pulse.

  13. Supercontinuum Fourier transform spectrometry with balanced detection on a single photodiode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goncharov, Vasily; Hall, Gregory

    Here, we have developed phase-sensitive signal detection and processing algorithms for Fourier transform spectrometers fitted with supercontinuum sources for applications requiring ultimate sensitivity. Similar to well-established approach of source noise cancellation through balanced detection of monochromatic light, our method is capable of reducing the relative intensity noise of polychromatic light by 40 dB. Unlike conventional balanced detection, which relies on differential absorption measured with a well matched pair of photo-detectors, our algorithm utilizes phase-sensitive differential detection on a single photodiode and is capable of the real-time correction for instabilities in supercontinuum spectral structure over a broad range of wavelengths. Inmore » the resulting method is universal in terms of applicable wavelengths and compatible with commercial spectrometers. We present a proof-of-principle experimental« less

  14. Supercontinuum Fourier transform spectrometry with balanced detection on a single photodiode

    DOE PAGES

    Goncharov, Vasily; Hall, Gregory

    2016-08-25

    Here, we have developed phase-sensitive signal detection and processing algorithms for Fourier transform spectrometers fitted with supercontinuum sources for applications requiring ultimate sensitivity. Similar to well-established approach of source noise cancellation through balanced detection of monochromatic light, our method is capable of reducing the relative intensity noise of polychromatic light by 40 dB. Unlike conventional balanced detection, which relies on differential absorption measured with a well matched pair of photo-detectors, our algorithm utilizes phase-sensitive differential detection on a single photodiode and is capable of the real-time correction for instabilities in supercontinuum spectral structure over a broad range of wavelengths. Inmore » the resulting method is universal in terms of applicable wavelengths and compatible with commercial spectrometers. We present a proof-of-principle experimental« less

  15. Detection of Bi-Directionality in Strain-Gage Balance Calibration Data

    NASA Technical Reports Server (NTRS)

    Ulbrich, Norbert

    2012-01-01

    An indicator variable was developed for both visualization and detection of bi-directionality in wind tunnel strain-gage balance calibration data. First, the calculation of the indicator variable is explained in detail. Then, a criterion is discussed that may be used to decide which gage outputs of a balance have bi- directional behavior. The result of this analysis could be used, for example, to justify the selection of certain absolute value or other even function terms in the regression model of gage outputs whenever the Iterative Method is chosen for the balance calibration data analysis. Calibration data of NASA s MK40 Task balance is analyzed to illustrate both the calculation of the indicator variable and the application of the proposed criterion. Finally, bi directionality characteristics of typical multi piece, hybrid, single piece, and semispan balances are determined and discussed.

  16. Trends in ice sheet mass balance, 1992 to 2017

    NASA Astrophysics Data System (ADS)

    Shepherd, A.; Ivins, E. R.; Smith, B.; Velicogna, I.; Whitehouse, P. L.; Rignot, E. J.; van den Broeke, M. R.; Briggs, K.; Hogg, A.; Krinner, G.; Joughin, I. R.; Nowicki, S.; Payne, A. J.; Scambos, T.; Schlegel, N.; Moyano, G.; Konrad, H.

    2017-12-01

    The Ice Sheet Mass Balance Inter-Comparison Exercise (IMBIE) is a community effort, jointly supported by ESA and NASA, that aims to provide a consensus estimate of ice sheet mass balance from satellite gravimetry, altimetry and mass budget assessments, on an annual basis. The project has five experiment groups, one for each of the satellite techniques and two others to analyse surface mass balance (SMB) and glacial isostatic adjustment (GIA). The basic premise for the exercise is that individual ice sheet mass balance datasets are generated by project participants using common spatial and temporal domains to allow meaningful inter-comparison, and this controlled comparison in turn supports aggregation of the individual datasets over their full period. Participation is open to the full community, and the quality and consistency of submissions is regulated through a series of data standards and documentation requirements. The second phase of IMBIE commenced in 2015, with participant data submitted in 2016 and a combined estimate due for public release in 2017. Data from 48 participant groups were submitted to one of the three satellite mass balance technique groups or to the ancillary dataset groups. The individual mass balance estimates and ancillary datasets have been compared and combined within the respective groups. Following this, estimates of ice sheet mass balance derived from the individual techniques were then compared and combined. The result is single estimates of ice sheet mass balance for Greenland, East Antarctica, West Antarctica, and the Antarctic Peninsula. The participants, methodology and results of the exercise will be presented in this paper.

  17. Two-Phase Item Selection Procedure for Flexible Content Balancing in CAT

    ERIC Educational Resources Information Center

    Cheng, Ying; Chang, Hua-Hua; Yi, Qing

    2007-01-01

    Content balancing is an important issue in the design and implementation of computerized adaptive testing (CAT). Content-balancing techniques that have been applied in fixed content balancing, where the number of items from each content area is fixed, include constrained CAT (CCAT), the modified multinomial model (MMM), modified constrained CAT…

  18. Flow Cytometric Immunobead Assay for Detection of BCR-ABL1 Fusion Proteins in Chronic Myleoid Leukemia: Comparison with FISH and PCR Techniques

    PubMed Central

    Recchia, Anna Grazia; Caruso, Nadia; Bossio, Sabrina; Pellicanò, Mariavaleria; De Stefano, Laura; Franzese, Stefania; Palummo, Angela; Abbadessa, Vincenzo; Lucia, Eugenio; Gentile, Massimo; Vigna, Ernesto; Caracciolo, Clementina; Agostino, Antolino; Galimberti, Sara; Levato, Luciano; Stagno, Fabio; Molica, Stefano; Martino, Bruno; Vigneri, Paolo; Di Raimondo, Francesco; Morabito, Fortunato

    2015-01-01

    Chronic Myeloid Leukemia (CML) is characterized by a balanced translocation juxtaposing the Abelson (ABL) and breakpoint cluster region (BCR) genes. The resulting BCR-ABL1 oncogene leads to increased proliferation and survival of leukemic cells. Successful treatment of CML has been accompanied by steady improvements in our capacity to accurately and sensitively monitor therapy response. Currently, measurement of BCR-ABL1 mRNA transcript levels by real-time quantitative PCR (RQ-PCR) defines critical response endpoints. An antibody-based technique for BCR-ABL1 protein recognition could be an attractive alternative to RQ-PCR. To date, there have been no studies evaluating whether flow-cytometry based assays could be of clinical utility in evaluating residual disease in CML patients. Here we describe a flow-cytometry assay that detects the presence of BCR-ABL1 fusion proteins in CML lysates to determine the applicability, reliability, and specificity of this method for both diagnosis and monitoring of CML patients for initial response to therapy. We show that: i) CML can be properly diagnosed at onset, (ii) follow-up assessments show detectable fusion protein (i.e. relative mean fluorescent intensity, rMFI%>1) when BCR-ABL1IS transcripts are between 1–10%, and (iii) rMFI% levels predict CCyR as defined by FISH analysis. Overall, the FCBA assay is a rapid technique, fully translatable to the routine management of CML patients. PMID:26111048

  19. Is adapted measured resection superior to gap-balancing in determining femoral component rotation in total knee replacement?

    PubMed

    Luyckx, T; Peeters, T; Vandenneucker, H; Victor, J; Bellemans, J

    2012-09-01

    Obtaining a balanced flexion gap with correct femoral component rotation is one of the prerequisites for a successful outcome after total knee replacement (TKR). Different techniques for achieving this have been described. In this study we prospectively compared gap-balancing versus measured resection in terms of reliability and accuracy for femoral component rotation in 96 primary TKRs performed in 96 patients using the Journey system. In 48 patients (18 men and 30 women) with a mean age of 65 years (45 to 85) a tensor device was used to determine rotation. In the second group of 48 patients (14 men and 34 women) with a mean age of 64 years (41 to 86), an 'adapted' measured resection technique was used, taking into account the native rotational geometry of the femur as measured on a pre-operative CT scan. Both groups systematically reproduced a similar external rotation of the femoral component relative to the surgical transepicondylar axis: 2.4° (SD 2.5) in the gap-balancing group and 1.7° (SD 2.1) in the measured resection group (p = 0.134). Both gap-balancing and adapted measured resection techniques proved equally reliable and accurate in determining femoral component rotation after TKR. There was a tendency towards more external rotation in the gap-balancing group, but this difference was not statistically significant (p = 0.134). The number of outliers for our 'adapted' measured resection technique was much lower than reported in the literature.

  20. Machine Learning Techniques for the Detection of Shockable Rhythms in Automated External Defibrillators

    PubMed Central

    Irusta, Unai; Morgado, Eduardo; Aramendi, Elisabete; Ayala, Unai; Wik, Lars; Kramer-Johansen, Jo; Eftestøl, Trygve; Alonso-Atienza, Felipe

    2016-01-01

    Early recognition of ventricular fibrillation (VF) and electrical therapy are key for the survival of out-of-hospital cardiac arrest (OHCA) patients treated with automated external defibrillators (AED). AED algorithms for VF-detection are customarily assessed using Holter recordings from public electrocardiogram (ECG) databases, which may be different from the ECG seen during OHCA events. This study evaluates VF-detection using data from both OHCA patients and public Holter recordings. ECG-segments of 4-s and 8-s duration were analyzed. For each segment 30 features were computed and fed to state of the art machine learning (ML) algorithms. ML-algorithms with built-in feature selection capabilities were used to determine the optimal feature subsets for both databases. Patient-wise bootstrap techniques were used to evaluate algorithm performance in terms of sensitivity (Se), specificity (Sp) and balanced error rate (BER). Performance was significantly better for public data with a mean Se of 96.6%, Sp of 98.8% and BER 2.2% compared to a mean Se of 94.7%, Sp of 96.5% and BER 4.4% for OHCA data. OHCA data required two times more features than the data from public databases for an accurate detection (6 vs 3). No significant differences in performance were found for different segment lengths, the BER differences were below 0.5-points in all cases. Our results show that VF-detection is more challenging for OHCA data than for data from public databases, and that accurate VF-detection is possible with segments as short as 4-s. PMID:27441719

  1. Machine Learning Techniques for the Detection of Shockable Rhythms in Automated External Defibrillators.

    PubMed

    Figuera, Carlos; Irusta, Unai; Morgado, Eduardo; Aramendi, Elisabete; Ayala, Unai; Wik, Lars; Kramer-Johansen, Jo; Eftestøl, Trygve; Alonso-Atienza, Felipe

    2016-01-01

    Early recognition of ventricular fibrillation (VF) and electrical therapy are key for the survival of out-of-hospital cardiac arrest (OHCA) patients treated with automated external defibrillators (AED). AED algorithms for VF-detection are customarily assessed using Holter recordings from public electrocardiogram (ECG) databases, which may be different from the ECG seen during OHCA events. This study evaluates VF-detection using data from both OHCA patients and public Holter recordings. ECG-segments of 4-s and 8-s duration were analyzed. For each segment 30 features were computed and fed to state of the art machine learning (ML) algorithms. ML-algorithms with built-in feature selection capabilities were used to determine the optimal feature subsets for both databases. Patient-wise bootstrap techniques were used to evaluate algorithm performance in terms of sensitivity (Se), specificity (Sp) and balanced error rate (BER). Performance was significantly better for public data with a mean Se of 96.6%, Sp of 98.8% and BER 2.2% compared to a mean Se of 94.7%, Sp of 96.5% and BER 4.4% for OHCA data. OHCA data required two times more features than the data from public databases for an accurate detection (6 vs 3). No significant differences in performance were found for different segment lengths, the BER differences were below 0.5-points in all cases. Our results show that VF-detection is more challenging for OHCA data than for data from public databases, and that accurate VF-detection is possible with segments as short as 4-s.

  2. Leak detection by mass balance effective for Norman Wells line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liou, J.C.P.

    Mass-balance calculations for leak detection have been shown as effective as a leading software system, in a comparison based on a major Canadian crude-oil pipeline. The calculations and NovaCorp`s Leakstop software each detected 4% (approximately) or greater leaks on Interprovincial Pipe Line (IPL) Inc.`s Norman Wells pipeline. Insufficient data exist to assess performances of the two methods for leaks smaller than 4%. Pipeline leak detection using such software-based systems are common. Their effectiveness is measured by how small and how quickly a leak can be detected. Algorithms used and measurement uncertainties determine leak detectability.

  3. 77 FR 31176 - Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-25

    ... currently requires inspecting the intermediate-pressure (IP) compressor rotor shaft rear balance land for... detect cracking on the IP compressor rotor rear balance land. IP compressor rotor rear balance land...), without sub-headings. Request To Delete the Re-Balance Requirement American Airlines requested that in the...

  4. Detection of compensatory balance responses using wearable electromyography sensors for fall-risk assessment.

    PubMed

    Nouredanesh, Mina; Kukreja, Sunil L; Tung, James

    2016-08-01

    Loss of balance is prevalent in older adults and populations with gait and balance impairments. The present paper aims to develop a method to automatically distinguish compensatory balance responses (CBRs) from normal gait, based on activity patterns of muscles involved in maintaining balance. In this study, subjects were perturbed by lateral pushes while walking and surface electromyography (sEMG) signals were recorded from four muscles in their right leg. To extract sEMG time domain features, several filtering characteristics and segmentation approaches are examined. The performance of three classification methods, i.e., k-nearest neighbor, support vector machines, and random forests, were investigated for accurate detection of CBRs. Our results show that features extracted in the 50-200Hz band, segmented using peak sEMG amplitudes, and a random forest classifier detected CBRs with an accuracy of 92.35%. Moreover, our results support the important role of biceps femoris and rectus femoris muscles in stabilization and consequently discerning CBRs. This study contributes towards the development of wearable sensor systems to accurately and reliably monitor gait and balance control behavior in at-home settings (unsupervised conditions), over long periods of time, towards personalized fall risk assessment tools.

  5. Sea Ice Mass Balance Buoys (IMBs): First Results from a Data Processing Intercomparison Study

    NASA Astrophysics Data System (ADS)

    Hoppmann, Mario; Tiemann, Louisa; Itkin, Polona

    2017-04-01

    IMBs are autonomous instruments able to continuously monitor the growth and melt of sea ice and its snow cover at a single point on an ice floe. Complementing field expeditions, remote sensing observations and modelling studies, these in-situ data are crucial to assess the mass balance and seasonal evolution of sea ice and snow in the polar oceans. Established subtypes of IMBs combine coarse-resolution temperature profiles through air, snow, ice and ocean with ultrasonic pingers to detect snow accumulation and ice thermodynamic growth. Recent technological advancements enable the use of high-resolution temperature chains, which are also able to identify the surrounding medium through a „heating cycle". The temperature change during this heating cycle provides additional information on the internal properties and processes of the ice. However, a unified data processing technique to reliably and accurately determine sea ice thickness and snow depth from this kind of data is still missing, and an unambiguous interpretation remains a challenge. Following the need to improve techniques for remotely measuring sea ice mass balance, an international IMB working group has recently been established. The main goals are 1) to coordinate IMB deployments, 2) to enhance current IMB data processing and -interpretation techniques, and 3) to provide standardized IMB data products to a broader community. Here we present first results from two different data processing algorithms, applied to selected IMB datasets from the Arctic and Antarctic. Their performance with regard to sea ice thickness and snow depth retrieval is evaluated, and an uncertainty is determined. Although several challenges and caveats in IMB data processing and -interpretation are found, such datasets bear great potential and yield plenty of useful information about sea ice properties and processes. It is planned to include many more algorithms from contributors within the working group, and we explicitly invite other interested scientists to join this promising effort.

  6. Strategic Management of Electronic Commerce: An Adaptation of the Balanced Scorecard.

    ERIC Educational Resources Information Center

    Hasan, Helen; Tibbits, Hendrika

    2000-01-01

    The balanced scorecard is a formal management technique built on the premise that measurement is a prerequisite to strategic management. A case study of the implementation of the balanced scorecard in a public utility is analyzed to suggest how the basic concepts and philosophy of the balanced scorecard can be retained in its adaptation to the…

  7. Use of Array Comparative Genomic Hybridization for the Diagnosis of DiGeorge Syndrome in Saudi Arabian Population.

    PubMed

    Bahamat, Abeer A; Assidi, Mourad; Lary, Sahira A; Almughamsi, Muna M; Peer Zada, Abdul A; Chaudhary, Adeel; Abuzenadah, Adel; Abu-Elmagd, Muhammad; Al-Qahtani, Mohammed

    2018-01-01

    DiGeorge syndrome (DGS) is a genetic disorder known as a clinically variable syndrome with over 180 associated phenotypic features. It is caused by a common human deletion in the 22q11.2 chromosomal region and currently is affecting approximately 1 in 4,000 individuals. Despite the prevalence of inherited diseases mainly due to consanguineous marriages, the current diagnosis of DGS in Saudi Arabia is mainly based on conventional high-resolution chromosome banding (karyotyping) and FISH techniques. However, advanced genome-wide studies for detecting microdeletions or duplications across the whole genome are needed. The aim of this study is to implement and use aCGH technology in clinical diagnosis of the 22q11.2 deletion in Saudi Arabian DGS patients and to confirm its effectiveness compared to conventional FISH and chromosome banding techniques. Thirty suspected DGS patients were assessed for chromosome 22q11.2 deletion using high-resolution G-banding, FISH, and aCGH. The aCGH results were compared with those obtained by the other 2 cytogenetic techniques. G-banding detected the 22q11.2 deletion in only 1 patient in the cohort. Moreover, it detected additional chromosomal aberrations in 3 other patients. Using FISH, allowed for detection of the 22q11.2 deletion in 2 out of 30 patients. Interestingly, the use of aCGH technique showed deletions in the chromosome 22q11.2 region in 8 patients, indicating a 4-fold increase in diagnostic detection capacity compared to FISH. Our results show the effectiveness of aCGH to overcome the limitations of FISH and G-banding in terms of diagnostic yield and allow whole genome screening and detection of a larger number of deletions and/or duplications in Saudi Arabian DGS patients. Except for balanced translocations and inversions, our data demonstrate the suitability of aCGH in the diagnostics of submicroscopic deletion syndromes such as DGS and most chromosomal aberrations or complex abnormalities scattered throughout the human genome. Our results recommend the implementation of aCGH in clinical genomic testing in Saudi Arabia to improve the diagnostic capabilities of health services while maintaining the use of conventional cytogenetic techniques for subsequent validation or for specific and known aberrations whenever required. © 2018 S. Karger AG, Basel.

  8. Automated Track Recognition and Event Reconstruction in Nuclear Emulsion

    NASA Technical Reports Server (NTRS)

    Deines-Jones, P.; Cherry, M. L.; Dabrowska, A.; Holynski, R.; Jones, W. V.; Kolganova, E. D.; Kudzia, D.; Nilsen, B. S.; Olszewski, A.; Pozharova, E. A.; hide

    1998-01-01

    The major advantages of nuclear emulsion for detecting charged particles are its submicron position resolution and sensitivity to minimum ionizing particles. These must be balanced, however, against the difficult manual microscope measurement by skilled observers required for the analysis. We have developed an automated system to acquire and analyze the microscope images from emulsion chambers. Each emulsion plate is analyzed independently, allowing coincidence techniques to be used in order to reject back- ground and estimate error rates. The system has been used to analyze a sample of high-multiplicity Pb-Pb interactions (charged particle multiplicities approx. 1100) produced by the 158 GeV/c per nucleon Pb-208 beam at CERN. Automatically reconstructed track lists agree with our best manual measurements to 3%. We describe the image analysis and track reconstruction techniques, and discuss the measurement and reconstruction uncertainties.

  9. Rotary and Magnus balances

    NASA Technical Reports Server (NTRS)

    Malcolm, G. N.

    1981-01-01

    Two wind tunnel techniques for determining part of the aerodynamic information required to describe the dynamic bahavior of various types of vehicles in flight are described. Force and moment measurements are determined with a rotary-balance apparatus in a coning motion and with a Magnus balance in a high-speed spinning motion. Coning motion is pertinent to both aircraft and missiles, and spinning is important for spin stabilized missiles. Basic principles of both techniques are described, and specific examples of each type of apparatus are presented. Typical experimental results are also discussed.

  10. Continuous measurement of drying rate of crystalline and amorphous systems during freeze-drying using an in situ microbalance technique.

    PubMed

    Roth, C; Winter, G; Lee, G

    2001-09-01

    The use of a novel microbalance (Christ) technique to monitor continuously the weight loss of a vial standing on a shelf of a freeze-dryer has been investigated. The drying rates of the following aqueous solutions were measured during the primary drying phase of a complete freeze-drying cycle: sucrose (75 mg/mL, 2.5-mL fill volume), sucrose and phenylalanine (1:0.2 by weight, 75 mg/mL, 2.5-mL fill volume), and mannitol (75mg/mL, 2.5-mL fill volume). The microbalance yields the cumulative water loss, m(cu) in grams, and the momentary drying rate, Deltam(cu)/Deltat in mg/10 min, of the frozen cake. The momentary drying rate curves were especially useful for examining how Deltam(cu)/Deltat changes with time during primary drying. Initially, Deltam(cu)/Deltat rises to a sharp maximum and then decreases in a fashion depending on shelf temperature, chamber pressure, and the nature of the substance being dried. Different drying behavior was observed for the sucrose and sucrose/phenylalanine systems, which was attributed to the presence of crystalline phenylalanine in the amorphous sucrose. At low shelf-temperature (-24 degrees C) the crystalline mannitol showed lower Deltam(cu)/Deltat than with either sucrose or sucrose/phenylalanine. The balance could also detect differences in Deltam(cu)/Deltat when using different freezing protocols. "Slow" and "moderate" freezing protocols gave similar drying behavior, but "rapid" freezing in liquid nitrogen produced greatly altered drying rate and internal cake morphology. The balance also could be used to detect the endpoint of primary drying. Different endpoint criteria and their influence on final dried cake properties were examined. Copyright 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association

  11. Chemical Equation Balancing.

    ERIC Educational Resources Information Center

    Blakley, G. R.

    1982-01-01

    Reviews mathematical techniques for solving systems of homogeneous linear equations and demonstrates that the algebraic method of balancing chemical equations is a matter of solving a system of homogeneous linear equations. FORTRAN programs using this matrix method to chemical equation balancing are available from the author. (JN)

  12. RT-CW: widely tunable semiconductor THz QCL sources

    NASA Astrophysics Data System (ADS)

    Razeghi, M.; Lu, Q. Y.

    2016-09-01

    Distinctive position of Terahertz (THz) frequencies (ν 0.3 -10 THz) in the electromagnetic spectrum with their lower quantum energy compared to IR and higher frequency compared to microwave range allows for many potential applications unique to them. Especially in the security side of the THz sensing applications, the distinct absorption spectra of explosives and related compounds in the range of 0.1-5 THz makes THz technology a competitive technique for detecting hidden explosives. A compact, high power, room temperature continuous wave terahertz source emitting in a wide frequency range will greatly boost the THz applications for the diagnosis and detection of explosives. Here we present a new strong-coupled strain-balanced quantum cascade laser design for efficient THz generation based intracavity DFG. Room temperature continuous wave operation with electrical frequency tuning range of 2.06-4.35 THz is demonstrated.

  13. Fast imaging of live organisms with sculpted light sheets

    NASA Astrophysics Data System (ADS)

    Chmielewski, Aleksander K.; Kyrsting, Anders; Mahou, Pierre; Wayland, Matthew T.; Muresan, Leila; Evers, Jan Felix; Kaminski, Clemens F.

    2015-04-01

    Light-sheet microscopy is an increasingly popular technique in the life sciences due to its fast 3D imaging capability of fluorescent samples with low photo toxicity compared to confocal methods. In this work we present a new, fast, flexible and simple to implement method to optimize the illumination light-sheet to the requirement at hand. A telescope composed of two electrically tuneable lenses enables us to define thickness and position of the light-sheet independently but accurately within milliseconds, and therefore optimize image quality of the features of interest interactively. We demonstrated the practical benefit of this technique by 1) assembling large field of views from tiled single exposure each with individually optimized illumination settings; 2) sculpting the light-sheet to trace complex sample shapes within single exposures. This technique proved compatible with confocal line scanning detection, further improving image contrast and resolution. Finally, we determined the effect of light-sheet optimization in the context of scattering tissue, devising procedures for balancing image quality, field of view and acquisition speed.

  14. Technical strategy of triple jump: differences of inverted pendulum model between hop-dominated and balance techniques.

    PubMed

    Fujibayashi, Nobuaki; Otsuka, Mitsuo; Yoshioka, Shinsuke; Isaka, Tadao

    2017-10-24

    The present study aims to cross-sectionally clarify the characteristics of the motions of an inverted pendulum model, a stance leg, a swing leg and arms in different triple-jumping techniques to understand whether or not hop displacement is relatively longer rather than step and jump displacements. Eighteen male athletes performed the triple jump with a full run-up. Based on the technique of the jumpers, they were classified as hop-dominated (n = 10) or balance (n = 8) jumpers. The kinematic data were calculated using motion capture and compared between the two techniques using the inverted pendulum model. The hop-dominated jumpers had a significantly longer hop displacement and faster vertical centre-of-mass (COM) velocity of their whole body at hop take-off, which was generated by faster rotation behaviours of inverted pendulum model and faster swinging behaviours of arms. Conversely, balance jumpers had a significantly longer jump displacement and faster horizontal COM velocity of their whole body at take-off, which was generated by a stiffer inverted pendulum model and stance leg. The results demonstrate that hop-dominated and balance jumpers enhanced each dominated-jump displacement using different swing- and stance-leg motions. This information may help to enhance the actual displacement of triple jumpers using different jumping techniques.

  15. Generally applicable fed-batch culture concept based on the detection of metabolic state by on-line balancing.

    PubMed

    Jobé, Anna Marya; Herwig, Christoph; Surzyn, Martin; Walker, Bernhard; Marison, Ian; von Stockar, Urs

    2003-06-20

    In many microorganisms, flux limitations in oxidative metabolism lead to the formation of overflow metabolites even under fully aerobic conditions. This can be avoided if the specific growth rate is controlled at a low enough value. This is usually accomplished by controlling the substrate feeding profile in a fed-batch process. The present work proposes a control concept which is based on the on-line detection of metabolic state by on-line calculation of mass and elemental balances. The advantages of this method are: 1) the check of measurement consistency based on all of the available measurements, 2) the minimum requirement of a priori knowledge of metabolism, and 3) the exclusive use of simple and established on-line techniques which do not require direct measurement of the metabolite in question. The control concept has been linked to a simple adaptive controller and applied to fed-batch cultures of S. cerevisiae and E. coli, organisms which express different overflow metabolites, ethanol and acetic acid, respectively. Oxidative and oxidoreductive states of S. cerevisiae and E. coli cultures were detected with high precision. As demonstrated by the formation of acetic acid in E. coli cultures, metabolic states could be correctly distinguished for systems for which traditional methods, such as respiratory quotient (RQ), are insensitive. Hence, it could be shown that the control concept allowed avoidance of overflow metabolite formation and operation at maximum oxidative biomass productivity and oxidative conversion of substrate into biomass. Based on mass and elemental balances, the proposed method additionally provides a richness of additional information, such as yield coefficients and estimation of concentrations and specific conversion rates. These data certainly help the operator to additionally evaluate the state of the process on-line. Copyright 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 82: 627-639, 2003.

  16. Microwave photonic link with improved phase noise using a balanced detection scheme

    NASA Astrophysics Data System (ADS)

    Hu, Jingjing; Gu, Yiying; Tan, Wengang; Zhu, Wenwu; Wang, Linghua; Zhao, Mingshan

    2016-07-01

    A microwave photonic link (MPL) with improved phase noise performance using a dual output Mach-Zehnder modulator (DP-MZM) and balanced detection is proposed and experimentally demonstrated. The fundamental concept of the approach is based on the two complementary outputs of DP-MZM and the destructive combination of the photocurrent in balanced photodetector (BPD). Theoretical analysis is performed to numerical evaluate the additive phase noise performance and shows a good agreement with the experiment. Experimental results are presented for 4 GHz, 8 GHz and 12 GHz transmission link and an 11 dB improvement of phase noise performance at 10 MHz offset is achieved compared to the conventional intensity-modulation and direct-detection (IMDD) MPL.

  17. Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.; Volden, T.

    2014-01-01

    An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.

  18. Surgical technique for balancing posterior spinal fusions to the pelvis using the T square of Tolo.

    PubMed

    Andras, Lindsay; Yamaguchi, Kent T; Skaggs, David L; Tolo, Vernon T

    2012-12-01

    Correcting pelvic obliquity and improving sitting balance in neuromuscular scoliosis often requires fixation to the pelvis. We describe the use of a T square instrument to assist intraoperatively in evaluating the alignment of these curves and achieving balance in the coronal plane. The T square instrument was constructed with a vertical limb perpendicular to 2 horizontal limbs in a T formation. At the conclusion of the instrumentation and preliminary reduction maneuvers, the T square was positioned with the horizontal limbs parallel to the pelvis and the vertical limb in line with the central sacral line. If the spine and pelvis were well balanced, fluoroscopic images demonstrated that the superior aspect of the vertical limb of the T square was crossing the vertebral body of T1. If this was not shown, then some combination of compression, distraction, or a change in the contouring of the rods was performed until this balance was achieved. In this series, we describe case examples in which the T square has been successfully used to aid in achieving balance in the coronal plane. This technique helps to overcome the challenges with positioning and imaging often encountered in managing these long, rigid curves. The T square is a useful adjunct in balancing posterior spinal fusions and evaluating the correction of pelvic obliquity in cases of neuromuscular scoliosis. This novel, yet simple, T square technique can be used for any method of posterior spinal fusion with lumbopelvic fixation to assist in the intraoperative evaluation and achievement of balance in the coronal plane and has become routine at our institution. IV.

  19. Detecting Behavioral Deficits in Rats After Traumatic Brain Injury

    PubMed Central

    Parsley, Margaret A.; Guptarak, Jutatip; Spratt, Heidi; Sell, Stacy L.

    2018-01-01

    With the increasing incidence of traumatic brain injury (TBI) in both civilian and military populations, TBI is now considered a chronic disease; however, few studies have investigated the long-term effects of injury in rodent models of TBI. Shown here are behavioral measures that are well-established in TBI research for times early after injury, such as two weeks, until two months. Some of these methods have previously been used at later times after injury, up to one year, but by very few laboratories. The methods demonstrated here are a short neurological assessment to test reflexes, a Beam-Balance to test balance, a Beam-Walk to test balance and motor coordination, and a working memory version of the Morris water maze that can be sensitive to deficits in reference memory. Male rats were handled and pre-trained to neurological, balance, and motor coordination tests prior to receiving parasagittal fluid percussion injury (FPI) or sham injury. Rats can be tested on the short neurological assessment (neuroscore), the beam-balance, and the Beam-Walk multiple times, while testing on the water maze can only be done once. This difference is because rats can remember the task, thus confounding the results if repeated testing is attempted in the same animal. When testing from one to three days after injury, significant differences are detected in all three non-cognitive tasks. However, differences in the Beam-Walk task were not detectable at later time points (after 3 months). Deficits were detected at 3 months in the Beam-Balance and at 6 months in the neuroscore. Deficits in working memory were detected out to 12 months after injury, and a deficit in a reference memory first appeared at 12 months. Thus, standard behavioral tests can be useful measures of persistent behavioral deficits after FPI. PMID:29443022

  20. A calibration rig for multi-component internal strain gauge balance using the new design-of-experiment (DOE) approach

    NASA Astrophysics Data System (ADS)

    Nouri, N. M.; Mostafapour, K.; Kamran, M.

    2018-02-01

    In a closed water-tunnel circuit, the multi-component strain gauge force and moment sensor (also known as balance) are generally used to measure hydrodynamic forces and moments acting on scaled models. These balances are periodically calibrated by static loading. Their performance and accuracy depend significantly on the rig and the method of calibration. In this research, a new calibration rig was designed and constructed to calibrate multi-component internal strain gauge balances. The calibration rig has six degrees of freedom and six different component-loading structures that can be applied separately and synchronously. The system was designed based on the applicability of formal experimental design techniques, using gravity for balance loading and balance positioning and alignment relative to gravity. To evaluate the calibration rig, a six-component internal balance developed by Iran University of Science and Technology was calibrated using response surface methodology. According to the results, calibration rig met all design criteria. This rig provides the means by which various methods of formal experimental design techniques can be implemented. The simplicity of the rig saves time and money in the design of experiments and in balance calibration while simultaneously increasing the accuracy of these activities.

  1. Activated recombinative desorption: A potential component in mechanisms of spacecraft glow

    NASA Technical Reports Server (NTRS)

    Cross, J. B.

    1985-01-01

    The concept of activated recombination of atomic species on surfaces can explain the production of vibrationally and translationally excited desorbed molecular species. Equilibrium statistical mechanics predicts that the molecular quantum state distributions of desorbing molecules is a function of surface temperature only when the adsorption probability is unity and independent of initial collision conditions. In most cases, the adsorption probability is dependent upon initial conditions such as collision energy or internal quantum state distribution of impinging molecules. From detailed balance, such dynamical behavior is reflected in the internal quantum state distribution of the desorbing molecule. This concept, activated recombinative desorption, may offer a common thread in proposed mechanisms of spacecraft glow. Using molecular beam techniques and equipment available at Los Alamos, which includes a high translational energy 0-atom beam source, mass spectrometric detection of desorbed species, chemiluminescence/laser induced fluorescence detection of electronic and vibrationally excited reaction products, and Auger detection of surface adsorbed reaction products, a fundamental study of the gas surface chemistry underlying the glow process is proposed.

  2. Combining Radar and Optical Data for Forest Disturbance Studies

    NASA Technical Reports Server (NTRS)

    Ranson, K. Jon; Smith, David E. (Technical Monitor)

    2002-01-01

    Disturbance is an important factor in determining the carbon balance and succession of forests. Until the early 1990's researchers have focused on using optical or thermal sensors to detect and map forest disturbances from wild fires, logging or insect outbreaks. As part of a NASA Siberian mapping project, a study evaluated the capability of three different radar sensors (ERS, JERS and Radarsat) and an optical sensor (Landsat 7) to detect fire scars, logging and insect damage in the boreal forest. This paper describes the data sets and techniques used to evaluate the use of remote sensing to detect disturbance in central Siberian forests. Using images from each sensor individually and combined an assessment of the utility of using these sensors was developed. Transformed Divergence analysis and maximum likelihood classification revealed that Landsat data was the single best data type for this purpose. However, the combined use of the three radar and optical sensors did improve the results of discriminating these disturbances.

  3. Variations in Urine Calcium Isotope: Composition Reflect Changes in Bone Mineral Balance in Humans

    NASA Technical Reports Server (NTRS)

    Skulan, Joseph; Anbar, Ariel; Bullen, Thomas; Puzas, J. Edward; Shackelford, Linda; Smith, Scott M.

    2004-01-01

    Changes in bone mineral balance cause rapid and systematic changes in the calcium isotope composition of human urine. Urine from subjects in a 17 week bed rest study was analyzed for calcium isotopic composition. Comparison of isotopic data with measurements of bone mineral density and metabolic markers of bone metabolism indicates the calcium isotope composition of urine reflects changes in bone mineral balance. Urine calcium isotope composition probably is affected by both bone metabolism and renal processes. Calcium isotope. analysis of urine and other tissues may provide information on bone mineral balance that is in important respects better than that available from other techniques, and illustrates the usefulness of applying geochemical techniques to biomedical problems.

  4. A cost-effective line-based light-balancing technique using adaptive processing.

    PubMed

    Hsia, Shih-Chang; Chen, Ming-Huei; Chen, Yu-Min

    2006-09-01

    The camera imaging system has been widely used; however, the displaying image appears to have an unequal light distribution. This paper presents novel light-balancing techniques to compensate uneven illumination based on adaptive signal processing. For text image processing, first, we estimate the background level and then process each pixel with nonuniform gain. This algorithm can balance the light distribution while keeping a high contrast in the image. For graph image processing, the adaptive section control using piecewise nonlinear gain is proposed to equalize the histogram. Simulations show that the performance of light balance is better than the other methods. Moreover, we employ line-based processing to efficiently reduce the memory requirement and the computational cost to make it applicable in real-time systems.

  5. In vivo lipid saturation study of C. elegans using quantitative broadband coherent anti-Stokes Raman imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Littleton, Bradley; Kavanagh, Thomas; Nie, Yu; Abbate, Vincenzo; Hylands, Peter; Sturzenbaum, Stephen; Richards, David

    2016-03-01

    In vivo lipid saturation maps of microscopic nematodes (Caenorhabditis elegans) have been produced using our novel Spectral Interferometric Polarisation Coherent anti-Stokes Raman Scattering (SIP-CARS) imaging technique. This technique employs simple passive polarisation optics and a balanced homodyne detection scheme to exploit symmetries in the CARS polarisation response resulting in the complete cancellation of the non-resonant background (NRB) and real component of the CARS signal (with no prior or post assumptions as regards to their form). The remaining imaginary component of the CARS response is linear with analyte concentration and directly relatable to the spontaneous Raman spectrum [1]. Furthermore, the resonant CARS signal is interferometrically amplified by the non-resonant response, a necessity for rapid imaging at biologically relevant powers [2]. This technique permits acquisition of a broad NRB-free spectrum, in excess of 1800cm-1, in a single exposure at each pixel. This allows simultaneous determination of lipid droplet saturation, from the fingerprint region, and lipid order, from the C-H stretch region from which maps can be readily constructed. Additionally exploiting the dispersive nature of our signal collection two-photon autofluorescence can be isolated and images subsequently produced. We have successfully applied this technique to identify differences in lipid saturation distributions in selective C. elegans mutants and demonstrated that the technique is sufficiently sensitive to detect the effects of lipid metabolism altering drugs on wild type C. elegans. [1] Littleton et al, Phys Rev Lett, 111, 103902 (2013) [2] Parekh et al, Biophys J, 99, 2695-2704 (2010)

  6. Summary Report of the First International Symposium on Strain Gauge Balances and Workshop on AoA/Model Deformation Measurement Techniques

    NASA Technical Reports Server (NTRS)

    Tripp, John S.; Tcheng, Ping; Burner, Alpheus W.; Finley, Tom D.

    1999-01-01

    The first International Symposium on Strain Gauge Balances was sponsored under the auspices of the NASA Langley Research Center (LaRC), Hampton, Virginia during October 22-25, 1996. Held at the LaRC Reid Conference Center, the Symposium provided an open international forum for presentation, discussion, and exchange of technical information among wind tunnel test technique specialists and strain gauge balance designers. The Symposium also served to initiate organized professional activities among the participating and relevant international technical communities. The program included a panel discussion, technical paper sessions, tours of local facilities, and vendor exhibits. Over 130 delegates were in attendance from 15 countries. A steering committee was formed to plan a second international balance symposium tentatively scheduled to be hosted in the United Kingdom in 1998 or 1999. The Balance Symposium was followed by the half-day Workshop on Angle of Attack and Model Deformation on the afternoon of October 25. The thrust of the Workshop was to assess the state of the art in angle of attack (AoA) and model deformation measurement techniques and to discuss future developments.

  7. Propensity score method: a non-parametric technique to reduce model dependence

    PubMed Central

    2017-01-01

    Propensity score analysis (PSA) is a powerful technique that it balances pretreatment covariates, making the causal effect inference from observational data as reliable as possible. The use of PSA in medical literature has increased exponentially in recent years, and the trend continue to rise. The article introduces rationales behind PSA, followed by illustrating how to perform PSA in R with MatchIt package. There are a variety of methods available for PS matching such as nearest neighbors, full matching, exact matching and genetic matching. The task can be easily done by simply assigning a string value to the method argument in the matchit() function. The generic summary() and plot() functions can be applied to an object of class matchit to check covariate balance after matching. Furthermore, there is a useful package PSAgraphics that contains several graphical functions to check covariate balance between treatment groups across strata. If covariate balance is not achieved, one can modify model specifications or use other techniques such as random forest and recursive partitioning to better represent the underlying structure between pretreatment covariates and treatment assignment. The process can be repeated until the desirable covariate balance is achieved. PMID:28164092

  8. An Examination of Exposure Control and Content Balancing Restrictions on Item Selection in CATs Using the Partial Credit Model.

    ERIC Educational Resources Information Center

    Davis, Laurie Laughlin; Pastor, Dena A.; Dodd, Barbara G.; Chiang, Claire; Fitzpatrick, Steven J.

    2003-01-01

    Examined the effectiveness of the Sympson-Hetter technique and rotated content balancing relative to no exposure control and no content rotation conditions in a computerized adaptive testing system based on the partial credit model. Simulation results show the Sympson-Hetter technique can be used with minimal impact on measurement precision,…

  9. Impact localization and energy quantification based on the power flow: A low-power requirement approach

    NASA Astrophysics Data System (ADS)

    Guyomar, Daniel; Lallart, Mickaël; Petit, Lionel; Wang, Xing-Jun

    2011-06-01

    The increasing use of composite materials has led to a dramatic change in the definition of safety standards. In particular, composite structures may be subjected to internal damages caused by external impacts that may not be detected by classical inspection methods. Additional constraints related to energy requirements may also be considered in order to make the system autonomous and possibly self-powered. The purpose of this paper is to present a low-cost impact detection and quantification scheme for thin plates or shells giving the whole history of the structure solicitation. Based on the analysis of the energy that has flown over a monitored area through the use of the elastic Poynting vector (that relates the mechanical power density of travelling waves), it is shown that this global energy balance may be linked in a simple way to the voltage output of piezoelectric elements in open-circuit condition. From this estimation, it is therefore possible to detect if an impact occurred inside the monitored area (in this case, the global energy balance would be positive) as well as its associated energy. If the impact occurs out of the frame, the global energy (and thus the obtained estimator) would be negative because of energy dissipation caused by internal losses and almost null. Thanks to this energy flow approach, the system is also independent from the boundary conditions of the structure. Experimental measurements aiming at validating the theoretical predictions showed that the technique permits detecting the impact area (inside/outside the frame) as well as an accurate estimation of the impact energy if the latter occurred inside the frame, both on a steel plate (with different boundary conditions) and an anisotropic composite structure.

  10. State of balance of the cryosphere

    NASA Technical Reports Server (NTRS)

    Van Der Veen, C. J.

    1991-01-01

    Available observations and mass balance estimates of the cryosphere are summarized. Problems discussed include mountain glaciers, the Greenland ice sheet, the Antarctic ice sheet, conventional glacier measurement techniques, and satellite applications in glacier mass balance studies. It is concluded that the interior part of the Greenland ice sheet is thickening or in near equilibrium. Estimates of the mass balance of the Antarctic ice sheet suggest that it is positive, although the error limits allow for a slightly negative balance.

  11. Human balance, the evolution of bipedalism and dysequilibrium syndrome.

    PubMed

    Skoyles, John R

    2006-01-01

    A new model of the uniqueness, nature and evolution of human bipedality is presented in the context of the etiology of the balance disorder of dysequilibrium syndrome. Human bipedality is biologically novel in several remarkable respects. Humans are (a) obligate, habitual and diverse in their bipedalism, (b) hold their body carriage spinally erect in a multisegmental "antigravity pole", (c) use their forelimbs exclusively for nonlocomotion, (d) support their body weight exclusively by vertical balance and normally never use prehensile holds. Further, human bipedalism is combined with (e) upper body actions that quickly shift the body's center of mass (e.g. tennis serves, piggy-back carrying of children), (f) use transient unstable erect positions (dance, kicking and fighting), (g) body height that makes falls injurious, (h) stiff gait walking, and (i) endurance running. Underlying these novelties, I conjecture, is a species specific human vertical balance faculty. This faculty synchronizes any action with a skeletomuscular adjustment that corrects its potential destabilizing impact upon the projection of the body's center of mass over its foot support. The balance faculty depends upon internal models of the erect vertical body's geometrical relationship (and its deviations) to its support base. Due to the situation that humans are obligate erect terrestrial animals, two frameworks - the body- and gravity-defined frameworks - are in constant alignment in the vertical z-axis. This alignment allows human balance to adapt egocentric body cognitions to detect body deviations from the gravitational vertical. This link between human balance and the processing of geometrical orientation, I propose, accounts for the close link between balance and spatial cognition found in the cerebral cortex. I argue that cortical areas processing the spatial and other cognitions needed to enable vertical balance was an important reason for brain size expansion of Homo erectus. A novel source of evidence for this conjecture is the rare autosomal recessive condition of dysequilibrium syndrome. In dysequilibrium syndrome, individuals fail to learn to walk bipedally (with this not being due to sensory, vestibular nor motor coordination defects). Dysequilibrium syndrome is associated with severe spatial deficits that I conjecture underlie its balance dysfunction. The associated brain defects and gene mutations of dysequilibrium syndrome provide new opportunities to investigate (i) the neurological processes responsible for the human specific balance faculty, and (ii) through gene dating techniques, its evolution.

  12. Multiple needle puncturing: balancing the varus knee.

    PubMed

    Bellemans, Johan

    2011-09-09

    The so-called "pie crusting" technique using multiple stab incisions is a well-established procedure for correcting tightness of the iliotibial band in the valgus knee. It is, however, not applicable for balancing the medial side in varus knees because of the risk for iatrogenic transsection of the medial collateral ligament (MCL). This article presents our experience with a safer alternative and minimally invasive technique for medial soft tissue balancing, where we make multiple punctures in the MCL using a 19-gauge needle to progressively stretch the MCL until a correct ligament balance is achieved. Our technique requires minimal to no additional soft tissue dissection and can even be performed percutaneously when necessary. This technique, therefore, does not impact the length of the skin or soft tissue incisions. We analyzed 61 cases with varus deformity that were intraoperatively treated using this technique. In 4 other cases, the technique was used as a percutaneous procedure to correct postoperative medial tightness that caused persistent pain on the medial side. The procedure was considered successful when a 2- to 4-mm mediolateral joint line opening was obtained in extension and 2 to 6 mm in flexion. In 62 cases (95%), a progressive correction of medial tightness was achieved according to the above-described criteria. Three cases were overreleased and required compensatory release of the lateral structures and use of a thicker insert. Based on these results, we consider needle puncturing an effective and safe technique for progressive correction of MCL tightness during minimally invasive total knee arthroplasty. Copyright 2011, SLACK Incorporated.

  13. Apical extrusion of debris and irrigants using two hand and three engine-driven instrumentation techniques.

    PubMed

    Ferraz, C C; Gomes, N V; Gomes, B P; Zaia, A A; Teixeira, F B; Souza-Filho, F J

    2001-07-01

    To evaluate the weight of debris and irrigant volume extruded apically from extracted teeth in vitro after endodontic instrumentation using the balanced force technique, a hybrid hand instrumentation technique, and three engine-driven techniques utilizing nickel-titanium instruments (ProFile .04, Quantec 2000 and Pow-R). Five groups of 20 extracted human teeth with single canals were instrumented using one or other of five techniques: balanced force, hybrid, Quantec 2000, ProFile .04, or Pow-R. Debris extruded from the apical foramen during instrumentation were collected into preweighed 1.5 mL tubes. Following instrumentation, the volume of extruded irrigant fluid was determined by visual comparison to control centrifuge tubes filled with 0.25 mL increments of distilled water. The weight of dry extruded dentine debris was also established. Overall, the engine-driven techniques extruded less debris than the manual ones. However, there was no statistical difference between the balanced force technique and the engine-driven methods. The volume of irrigant extruded through the apex was directly associated with the weight of extruded debris, except within the ProFile group. The hybrid technique was associated with the greatest extrusion of both debris and irrigant. Overall, the engine-driven nickel-titanium systems were associated with less apical extrusion.

  14. A Model-Based Approach for Identifying Signatures of Ancient Balancing Selection in Genetic Data

    PubMed Central

    DeGiorgio, Michael; Lohmueller, Kirk E.; Nielsen, Rasmus

    2014-01-01

    While much effort has focused on detecting positive and negative directional selection in the human genome, relatively little work has been devoted to balancing selection. This lack of attention is likely due to the paucity of sophisticated methods for identifying sites under balancing selection. Here we develop two composite likelihood ratio tests for detecting balancing selection. Using simulations, we show that these methods outperform competing methods under a variety of assumptions and demographic models. We apply the new methods to whole-genome human data, and find a number of previously-identified loci with strong evidence of balancing selection, including several HLA genes. Additionally, we find evidence for many novel candidates, the strongest of which is FANK1, an imprinted gene that suppresses apoptosis, is expressed during meiosis in males, and displays marginal signs of segregation distortion. We hypothesize that balancing selection acts on this locus to stabilize the segregation distortion and negative fitness effects of the distorter allele. Thus, our methods are able to reproduce many previously-hypothesized signals of balancing selection, as well as discover novel interesting candidates. PMID:25144706

  15. A model-based approach for identifying signatures of ancient balancing selection in genetic data.

    PubMed

    DeGiorgio, Michael; Lohmueller, Kirk E; Nielsen, Rasmus

    2014-08-01

    While much effort has focused on detecting positive and negative directional selection in the human genome, relatively little work has been devoted to balancing selection. This lack of attention is likely due to the paucity of sophisticated methods for identifying sites under balancing selection. Here we develop two composite likelihood ratio tests for detecting balancing selection. Using simulations, we show that these methods outperform competing methods under a variety of assumptions and demographic models. We apply the new methods to whole-genome human data, and find a number of previously-identified loci with strong evidence of balancing selection, including several HLA genes. Additionally, we find evidence for many novel candidates, the strongest of which is FANK1, an imprinted gene that suppresses apoptosis, is expressed during meiosis in males, and displays marginal signs of segregation distortion. We hypothesize that balancing selection acts on this locus to stabilize the segregation distortion and negative fitness effects of the distorter allele. Thus, our methods are able to reproduce many previously-hypothesized signals of balancing selection, as well as discover novel interesting candidates.

  16. Influence of intentional femoral component flexion in navigated TKA on gap balance and sagittal anatomy.

    PubMed

    Roßkopf, J; Singh, P K; Wolf, P; Strauch, M; Graichen, H

    2014-03-01

    Navigation has proven its ability to accurately restore coronal leg axis; however, for a good clinical outcome, other factors such as sagittal anatomy and balanced gaps are at least as important. In a gap-balanced technique, the size of the flexion gap is equalled to that of the extension gap. Flexion of the femoral component has been described as a theoretical possibility to balance flexion and extension gap. Aim of this study was to assess whether intentional femoral component flexion is helpful in balancing TKA gaps and in restoring sagittal anatomy. One hundred and thirty-one patients with TKA were included in this study. Implantation was performed in a navigated, gap-balanced, tibia-first technique. The femoral component flexion needed to equal flexion to extension gap was calculated based upon the navigation data. The sagittal diameter, the anterior and posterior offset were measured pre- and postoperatively based on the lateral radiographs. Medial and lateral gaps in extension and flexion as well as flexion/extension gap differences pre- and postoperatively were analysed. Additionally range of motion (ROM) and patient satisfaction (SF 12) were obtained. To achieve equal flexion and extension gap, the femoral component was flexed in 120 out of 131 patients showing mean flexion of 2.9° (SD 2.2°; navigation data) and 3.1° (SD 2.0°; radiological analysis), respectively. Based on this technique, it was possible to balance the extension gap (<2 mm difference) in 130 out of 131 patients (99%) and the flexion gap in 119 out of 131 (91%). The difference between extension and flexion gap was reduced from 39 to 24 out of 131 patients (81%) on the medial side and from 69 to 28 on the lateral side (79%). The sagittal diameter was restored in 114 out of 131 cases (87%); however, anterior offset was significantly reduced by 1.3 mm (SD 3.9°), and posterior offset was significantly increased by 1.6 mm (SD 3.3°). No correlation between any navigation and radiological parameter was found with ROM and SF 12. The navigation-based, gap-balanced technique allows intentional flexion of the femoral component in order to balance gaps in more than 90% of primary TKA cases. Simultaneously, the sagittal diameter is restored in 87% of patients. However, to achieve equal gaps, the posterior offset is significantly increased by 1.6 mm and the femoral component is flexed by 3°. To evaluate the effect of this technique on the clinical outcome, future studies are needed. II.

  17. Certification trails for data structures

    NASA Technical Reports Server (NTRS)

    Sullivan, Gregory F.; Masson, Gerald M.

    1993-01-01

    Certification trails are a recently introduced and promising approach to fault detection and fault tolerance. The applicability of the certification trail technique is significantly generalized. Previously, certification trails had to be customized to each algorithm application; trails appropriate to wide classes of algorithms were developed. These certification trails are based on common data-structure operations such as those carried out using these sets of operations such as those carried out using balanced binary trees and heaps. Any algorithms using these sets of operations can therefore employ the certification trail method to achieve software fault tolerance. To exemplify the scope of the generalization of the certification trail technique provided, constructions of trails for abstract data types such as priority queues and union-find structures are given. These trails are applicable to any data-structure implementation of the abstract data type. It is also shown that these ideals lead naturally to monitors for data-structure operations.

  18. Perceptions of diabetes obtained through drawing in childhood and adolescence

    PubMed Central

    Pera, Pilar Isla; Lois, María Palacin; Matheu, Carmen López; Pérez, María Honrubia; Rodriguez, Ana María Gómez; Camps, Eulalia Armengol; Villalba, Carmen Sanchez; Soria, Roser Insa; Cuadra, Assumpta Rigol; Marre, Diana

    2013-01-01

    Objective To examine whether drawing is useful in the detection of problems of psychosocial adaptation in children and adolescents with type 1 diabetes (T1D) and in improving communication with health professionals. Methods We performed an exploratory descriptive study in 199 children and adolescents with T1D aged 4–13 years. The participants were asked to render a drawing on a suggested topic. The variables analyzed were related to the drawing and to clinical and sociodemographic data. Results Most participants showed evidence of having a well-balanced personality, but there were also signs of affective or psychosocial difficulties. Conclusion Drawing is a useful technique by which to identify children’s and adolescents’ feelings and possible problems in adapting to T1D, as well as to gain information directly from the children themselves. Future studies should delimit the possibilities of this technique in clinical practice in greater detail. PMID:23814467

  19. Recent Advances in Face Lift to Achieve Facial Balance.

    PubMed

    Ilankovan, Velupillai

    2017-03-01

    Facial balance is achieved by correction of facial proportions and the facial contour. Ageing affects this balance in addition to other factors. We have strived to inform all the recent advances in providing this balance. The anatomy of ageing including various changed in clinical features are described. The procedures are explained on the basis of the upper, middle and lower face. Different face lift, neck lift procedures with innovative techniques are demonstrated. The aim is to provide an unoperated balanced facial proportion with zero complication.

  20. Quantum state reconstruction and photon number statistics for low dimensional semiconductor opto-electronic devices

    NASA Astrophysics Data System (ADS)

    Böhm, Fabian; Grosse, Nicolai B.; Kolarczik, Mirco; Herzog, Bastian; Achtstein, Alexander; Owschimikow, Nina; Woggon, Ulrike

    2017-09-01

    Quantum state tomography and the reconstruction of the photon number distribution are techniques to extract the properties of a light field from measurements of its mean and fluctuations. These techniques are particularly useful when dealing with macroscopic or mesoscopic systems, where a description limited to the second order autocorrelation soon becomes inadequate. In particular, the emission of nonclassical light is expected from mesoscopic quantum dot systems strongly coupled to a cavity or in systems with large optical nonlinearities. We analyze the emission of a quantum dot-semiconductor optical amplifier system by quantifying the modifications of a femtosecond laser pulse propagating through the device. Using a balanced detection scheme in a self-heterodyning setup, we achieve precise measurements of the quadrature components and their fluctuations at the quantum noise limit1. We resolve the photon number distribution and the thermal-to-coherent evolution in the photon statistics of the emission. The interferometric detection achieves a high sensitivity in the few photon limit. From our data, we can also reconstruct the second order autocorrelation function with higher precision and time resolution compared with classical Hanbury Brown-Twiss experiments.

  1. Anomalous amplification of a homodyne signal via almost-balanced weak values.

    PubMed

    Liu, Wei-Tao; Martínez-Rincón, Julián; Viza, Gerardo I; Howell, John C

    2017-03-01

    We propose precision measurements of ultra-small angular velocities of a mirror within a modified Sagnac interferometer, where the counter-propagating beams are spatially separated, using the recently proposed technique of almost-balanced weak values amplification (ABWV) [Phys. Rev. Lett.116, 100803 (2016)PRLTAO0031-900710.1103/PhysRevLett.116.100803]. The separation between the two beams provides additional amplification with respect to using collinear beams in a Sagnac interferometer. Within the same setup, the weak-value amplification technique is also performed for comparison. Much higher amplification factors can be obtained using the almost-balanced weak values technique, with the best one achieved in our experiments being as high as 1.2×107. In addition, the amplification factor monotonically increases with decreasing of the post-selection phase for the ABWV case in our experiments, which is not the case for weak-value amplification (WVA) at small post-selection phases. Both techniques consist of measuring the angular velocity. The sensitivity of the ABWV technique is ∼38  nrad/s per averaged pulse for a repetition rate of 1 Hz and ∼33  nrad/s per averaged pulse for the WVA technique.

  2. Iron and Atherosclerosis: Nailing Down a Novel Target with Magnetic Resonance

    PubMed Central

    Sharkey-Toppen, Travis P.; Tewari, Arun K.; Raman, Subha V.

    2014-01-01

    Iron is an essential mineral in many proteins and enzymes in human physiology, with limited means of iron elimination to maintain iron balance. Iron accrual incurs various pathological mechanisms linked to cardiovascular disease. In atherosclerosis, iron catalyzes the creation of reactive oxygen free radicals that contribute to lipid modification, which is essential to atheroma formation. Inflammation further fuels iron-related pathologic processes associated with plaque progression. Given iron’s role in atherosclerosis development, in vivo detection techniques sensitive iron are needed for translational studies targeting iron for earlier diagnosis and treatment. Magnetic resonance imaging (MRI) is uniquely able to quantify iron in human tissues noninvasively and without ionizing radiation, offering appealing for longitudinal and interventional studies. Particularly intriguing is iron’s complementary biology vs. calcium, which is readily detectable by computed tomography (CT). This review summarizes the role of iron in atherosclerosis with considerable implications for novel diagnostic and therapeutic approaches. PMID:24590608

  3. Experimental Analysis of Propeller Interactions With a Flexible Wing Micro-Air-Vehicle

    DTIC Science & Technology

    2006-03-23

    Wing (Freestream Only) Momentum Balance Results.............. 94 Table 10. Flexible/ Rigid Wing (Freestream and Propeller Running) Momentum Balance ...107 Table 18. Propeller/MAV Forces and Moments at 14,000 RPM ( Rigid Wing) ............ 107 Table 19. Balance Data (Raw and Corrected...velocity field around the vehicle. A limited number of tests have been performed to assess the technique in comparison to force balance data. 4

  4. Sensitive Quantitative Assessment of Balance Disorders

    NASA Technical Reports Server (NTRS)

    Paloski, Willilam H.

    2007-01-01

    Computerized dynamic posturography (CDP) has become a standard technique for objectively quantifying balance control performance, diagnosing the nature of functional impairments underlying balance disorders, and monitoring clinical treatment outcomes. We have long used CDP protocols to assess recovery of sensory-motor function in astronauts following space flight. The most reliable indicators of post-flight crew performance are the sensory organization tests (SOTs), particularly SOTs 5 and 6, which are sensitive to changes in availability and/or utilization of vestibular cues. We have noted, however, that some astronauts exhibiting obvious signs of balance impairment after flight are able to score within clinical norms on these tests, perhaps as a result of adopting competitive strategies or by their natural skills at substituting alternate sensory information sources. This insensitivity of the CDP protocol could underestimate of the degree of impairment and, perhaps, lead to premature release of those crewmembers to normal duties. To improve the sensitivity of the CDP protocol we have introduced static and dynamic head tilt SOT trials into our protocol. The pattern of postflight recovery quantified by the enhanced CDP protocol appears to more aptly track the re-integration of sensory-motor function, with recovery time increasing as the complexity of sensory-motor/biomechanical task increases. The new CDP protocol therefore seems more suitable for monitoring post-flight sensory-motor recovery and for indicating to crewmembers and flight surgeons fitness for return to duty and/or activities of daily living. There may be classes of patients (e.g., athletes, pilots) having motivation and/or performance characteristics similar to astronauts whose sensory-motor treatment outcomes would also be more accurately monitored using the enhanced CDP protocol. Furthermore, the enhanced protocol may be useful in early detection of age-related balance disorders.

  5. Competing Strategies to Balance the Budgets of Publicly Funded Higher Education Institutions

    ERIC Educational Resources Information Center

    Askari, Mahmoud Yousef

    2017-01-01

    This paper compares and contrasts different strategies to balance academic institutions' operating budgets. Some strategies use economic theory to recommend a budgeting technique, others use management methods to cut cost, and some strategies use a management accounting approach to reach a balanced budget. Through the use of a simplified numerical…

  6. Hypersonic force measurements using internal balance based on optical micromachined Fabry-Perot interferometry.

    PubMed

    Qiu, Huacheng; Min, Fu; Zhong, Shaolong; Song, Xin; Yang, Yanguang

    2018-03-01

    Force measurements using wind tunnel balance are necessary for determining a variety of aerodynamic performance parameters, while the harsh environment in hypersonic flows requires that the measurement instrument should be reliable and robust, in against strong electromagnetic interference, high vacuum, or metal (oxide) dusts. In this paper, we demonstrated a three-component internal balance for hypersonic aerodynamic force measurements, using novel optical micromachined Fabry-Perot interferometric (FPI) strain gauges as sensing elements. The FPI gauges were fabricated using Micro-Opto-Electro-Mechanical Systems (MOEMS) surface and bulk fabrication techniques. High-reflectivity coatings are used to form a high-finesse Fabry-Perot cavity, which benefits a high resolution. Antireflective and passivation coatings are used to reduce unwanted interferences. The FPI strain gauge based balance has been calibrated and evaluated in a Mach 5 hypersonic flow. The results are compared with the traditional technique using the foil resistive strain gauge balance, indicating that the proposed balance based on the MOEMS FPI strain gauge is reliable and robust and is potentially suitable for the hypersonic wind tunnel harsh environment.

  7. Hypersonic force measurements using internal balance based on optical micromachined Fabry-Perot interferometry

    NASA Astrophysics Data System (ADS)

    Qiu, Huacheng; Min, Fu; Zhong, Shaolong; Song, Xin; Yang, Yanguang

    2018-03-01

    Force measurements using wind tunnel balance are necessary for determining a variety of aerodynamic performance parameters, while the harsh environment in hypersonic flows requires that the measurement instrument should be reliable and robust, in against strong electromagnetic interference, high vacuum, or metal (oxide) dusts. In this paper, we demonstrated a three-component internal balance for hypersonic aerodynamic force measurements, using novel optical micromachined Fabry-Perot interferometric (FPI) strain gauges as sensing elements. The FPI gauges were fabricated using Micro-Opto-Electro-Mechanical Systems (MOEMS) surface and bulk fabrication techniques. High-reflectivity coatings are used to form a high-finesse Fabry-Perot cavity, which benefits a high resolution. Antireflective and passivation coatings are used to reduce unwanted interferences. The FPI strain gauge based balance has been calibrated and evaluated in a Mach 5 hypersonic flow. The results are compared with the traditional technique using the foil resistive strain gauge balance, indicating that the proposed balance based on the MOEMS FPI strain gauge is reliable and robust and is potentially suitable for the hypersonic wind tunnel harsh environment.

  8. Skylab water balance analysis

    NASA Technical Reports Server (NTRS)

    Leonard, J. I.

    1977-01-01

    The water balance of the Skylab crew was analyzed. Evaporative water loss using a whole body input/output balance equation, water, body tissue, and energy balance was analyzed. The approach utilizes the results of several major Skylab medical experiments. Subsystems were designed for the use of the software necessary for the analysis. A partitional water balance that graphically depicts the changes due to water intake is presented. The energy balance analysis determines the net available energy to the individual crewman during any period. The balances produce a visual description of the total change of a particular body component during the course of the mission. The information is salvaged from metabolic balance data if certain techniques are used to reduce errors inherent in the balance method.

  9. A new surgical technique for medial collateral ligament balancing: multiple needle puncturing.

    PubMed

    Bellemans, Johan; Vandenneucker, Hilde; Van Lauwe, Johan; Victor, Jan

    2010-10-01

    In this article, we present our experience with a new technique for medial soft tissue balancing, where we make multiple punctures in the medial collateral ligament (MCL) using a 19-gauge needle, to progressively stretch the MCL until a correct ligament balance is achieved. Ligament status was evaluated both before and after the procedure using computer navigation and mediolateral stress testing. The procedure was considered successful when 2 to 4-mm mediolateral joint line opening was obtained in extension and 2 to 6 mm in flexion. In 34 of 35 cases, a progressive correction of medial tightness was achieved according to the above described criteria. One case was considered overreleased in extension. Needle puncturing is a new, effective, and safe technique for progressive correction of MCL tightness in the varus knee. Copyright © 2010 Elsevier Inc. All rights reserved.

  10. Supporting clinician educators to achieve “work-work balance”

    PubMed Central

    Maniate, Jerry; Dath, Deepak; Cooke, Lara; Leslie, Karen; Snell, Linda; Busari, Jamiu

    2016-01-01

    Clinician Educators (CE) have numerous responsibilities in different professional domains, including clinical, education, research, and administration. Many CEs face tensions trying to manage these often competing professional responsibilities and achieve “work-work balance.” Rich discussions of techniques for work-work balance amongst CEs at a medical education conference inspired the authors to gather, analyze, and summarize these techniques to share with others. In this paper we present the CE’s “Four Ps”; these are practice points that support both the aspiring and established CE to help improve their performance and productivity as CEs, and allow them to approach work-work balance. PMID:28344698

  11. Design and evaluation of controls for drift, video gain, and color balance in spaceborne facsimile cameras

    NASA Technical Reports Server (NTRS)

    Katzberg, S. J.; Kelly, W. L., IV; Rowland, C. W.; Burcher, E. E.

    1973-01-01

    The facsimile camera is an optical-mechanical scanning device which has become an attractive candidate as an imaging system for planetary landers and rovers. This paper presents electronic techniques which permit the acquisition and reconstruction of high quality images with this device, even under varying lighting conditions. These techniques include a control for low frequency noise and drift, an automatic gain control, a pulse-duration light modulation scheme, and a relative spectral gain control. Taken together, these techniques allow the reconstruction of radiometrically accurate and properly balanced color images from facsimile camera video data. These techniques have been incorporated into a facsimile camera and reproduction system, and experimental results are presented for each technique and for the complete system.

  12. Rotary balances: A selected, annotated bibliography

    NASA Technical Reports Server (NTRS)

    Tuttle, Marie H.; Kilgore, Robert A.; Sych, Karen L.

    1989-01-01

    This bibliography on rotary balances contains 102 entries. It is part of NASA's support of the AGARD Fluid Dynamics Panel Working Group 11 on Rotary Balances. This bibliography includes works that might be useful to anyone interested in building or using rotor balances. Emphasis is on the rotary balance rigs and testing techniques rather than the aerodynamic data. Also included are some publications of historical interest which relate to key events in the development and use of rotary balances. The arrangement is chronological by date of publication in the case of reports and by presentation in the case of papers.

  13. [The use of the balanced scorecard and the budget in the strategic management of public hospitals].

    PubMed

    Naranjo Gil, David

    2010-01-01

    To analyze the relationship between hospital managers' characteristics and the use of the balanced scorecard and the budget. A further aim was to analyze how these two techniques influence strategic goals aimed at cost reduction and enhancing service flexibility. Data were collected through a questionnaire sent to 884 members of top management teams in 218 public hospitals in Spain. The response rate was 53.51% with 473 useful questionnaires. Structural equation techniques were used to validate the metric scales and the model used. Younger managers and less tenured managers were more likely to use the balanced scorecard than the budget. Diversity in the top management team was related to the use of distinct management control techniques. The use of the balanced scorecard was positively associated with the implementation of healthcare strategies focused on enhancing service flexibility and reducing healthcare cost. The adoption of management control systems is not only a function of the outcome of a rational decision-making process and institutional pressures but also crucially depends on the characteristics of the individuals ultimately responsible for such decisions. The use of the balanced scorecard facilitates hospitals' implementation of plans with multiple strategic goals. Copyright 2009 SESPAS. Published by Elsevier Espana. All rights reserved.

  14. On the Power and the Systematic Biases of the Detection of Chromosomal Inversions by Paired-End Genome Sequencing

    PubMed Central

    Lucas Lledó, José Ignacio; Cáceres, Mario

    2013-01-01

    One of the most used techniques to study structural variation at a genome level is paired-end mapping (PEM). PEM has the advantage of being able to detect balanced events, such as inversions and translocations. However, inversions are still quite difficult to predict reliably, especially from high-throughput sequencing data. We simulated realistic PEM experiments with different combinations of read and library fragment lengths, including sequencing errors and meaningful base-qualities, to quantify and track down the origin of false positives and negatives along sequencing, mapping, and downstream analysis. We show that PEM is very appropriate to detect a wide range of inversions, even with low coverage data. However, % of inversions located between segmental duplications are expected to go undetected by the most common sequencing strategies. In general, longer DNA libraries improve the detectability of inversions far better than increments of the coverage depth or the read length. Finally, we review the performance of three algorithms to detect inversions —SVDetect, GRIAL, and VariationHunter—, identify common pitfalls, and reveal important differences in their breakpoint precisions. These results stress the importance of the sequencing strategy for the detection of structural variants, especially inversions, and offer guidelines for the design of future genome sequencing projects. PMID:23637806

  15. 78 FR 54149 - Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-03

    ...-10-12 required inspecting the intermediate-pressure (IP) compressor rotor shaft rear balance land for... Trent 500 IP compressor rotor shaft rear balance land during a shop visit. Further engineering... AD to detect cracking on the IP compressor rotor shaft rear balance land, which could lead to...

  16. A Universal Tare Load Prediction Algorithm for Strain-Gage Balance Calibration Data Analysis

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.

    2011-01-01

    An algorithm is discussed that may be used to estimate tare loads of wind tunnel strain-gage balance calibration data. The algorithm was originally developed by R. Galway of IAR/NRC Canada and has been described in the literature for the iterative analysis technique. Basic ideas of Galway's algorithm, however, are universally applicable and work for both the iterative and the non-iterative analysis technique. A recent modification of Galway's algorithm is presented that improves the convergence behavior of the tare load prediction process if it is used in combination with the non-iterative analysis technique. The modified algorithm allows an analyst to use an alternate method for the calculation of intermediate non-linear tare load estimates whenever Galway's original approach does not lead to a convergence of the tare load iterations. It is also shown in detail how Galway's algorithm may be applied to the non-iterative analysis technique. Hand load data from the calibration of a six-component force balance is used to illustrate the application of the original and modified tare load prediction method. During the analysis of the data both the iterative and the non-iterative analysis technique were applied. Overall, predicted tare loads for combinations of the two tare load prediction methods and the two balance data analysis techniques showed excellent agreement as long as the tare load iterations converged. The modified algorithm, however, appears to have an advantage over the original algorithm when absolute voltage measurements of gage outputs are processed using the non-iterative analysis technique. In these situations only the modified algorithm converged because it uses an exact solution of the intermediate non-linear tare load estimate for the tare load iteration.

  17. Selective Medial Release Technique Using the Pie-Crusting Method for Medial Tightness During Primary Total Knee Arthroplasty.

    PubMed

    Ha, Chul-Won; Park, Yong-Beom; Lee, Choong-Hee; Awe, Soo-Ik; Park, Yong-Geun

    2016-05-01

    The pie-crusting method is popular in releasing lateral tightness during primary total knee arthroplasty (TKA) but is not well described for medial release. We established a selective medial release technique using the pie-crusting technique and investigated the effectiveness and safety of the technique during primary TKA. We retrospectively reviewed 729 primary TKAs with varus deformity between October 2009 and June 2012. Medial tightness in flexion was released by traditional subperiosteal stripping for the anterior portion of the medial collateral ligament (aMCL). Medial tightness in extension was released by the pie crusting for the tight fibers in the posterior portion of the MCL and/or posteromedial corner structures (pMCL/PMCS). Clinical outcomes were evaluated by Knee Society (KS) scores and the Western Ontario and McMaster Universities Osteoarthritis Index. Any complications, including late medial instability that may be related to our surgical technique, were carefully inspected. Among the 729 knees, 170 (23.3%) required subperiosteal stripping for balancing in flexion only, 186 (25.5%) required the pie-crusting for balancing in extension only and 142 (19.5%) required subperiosteal stripping and the pie-crusting for balancing in flexion and extension. The KS knee score was improved from 52.5 to 83.4, KS function score from 58.2 to 91.9, and Western Ontario and McMaster Universities Osteoarthritis Index from 42.7 to 21.8 (P < .001, all). No specific complications related to our technique were identified. The selective medial release technique appears to be an effective and safe method to obtain a balanced mediolateral gap in primary TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Accountability in public health units: using a modified nominal group technique to develop a balanced scorecard for performance measurement.

    PubMed

    Robinson, Victoria A; Hunter, Duncan; Shortt, Samuel E D

    2003-01-01

    Little attention has been paid to the need for accountability instruments applicable across all health units in the public health system. One tool, the balanced scorecard was created for industry and has been successfully adapted for use in Ontario hospitals. It consists of 4 quadrants: financial performance, outcomes, customer satisfaction and organizational development. The aim of the present study was to determine if a modified nominal group technique could be used to reach consensus among public health unit staff and public health specialists in Ontario about the components of a balanced scorecard for public health units. A modified nominal group technique consensus method was used with the public health unit staff in 6 Eastern Ontario health units (n=65) and public health specialists (n=18). 73.8% of the public health unit personnel from all six health units in the eastern Ontario region participated in the survey of potential indicators. A total of 74 indicators were identified in each of the 4 quadrants: program performance (n=44); financial performance (n=11); public perceptions (n=11); and organizational performance (n=8). The modified nominal group technique was a successful method of incorporating the views of public health personnel and specialists in the development of a balanced scorecard for public health.

  19. Film Balance Studies of Membrane Lipids and Related Molecules

    ERIC Educational Resources Information Center

    Cadenhead, D. A.

    1972-01-01

    Discusses apparatus, techniques, and measurements used to determine cell membrane composition. The use of a film balance to study monolayer membranes of selected lipids is described and results reported. (TS)

  20. Force instrumentation for cryogenic wind tunnels using one-piece strain-gage balances

    NASA Technical Reports Server (NTRS)

    Ferris, A. T.; Moore, T. C.

    1981-01-01

    Materials and techniques for a transducer capable of obtaining accurate force measurements at cryogenic temperatures (down to 77 K) and high pressures (up to 9 atm) have been determined. Areas of high stress concentration are minimized by balance design, and model and sting attachment methods able to withstand cryogenic temperatures are used. Maraging 200 is the material used for the balances, due to its high impact strength and simple heat treatment procedure. Test results verify that the balances produce reliable, repeatable, and predictable data from 300 K to 110 K under steady state conditions. Techniques have been developed to reduce the temperature-induced bridge output, such as the use of bridges with two gages mounted transverse to the principal stress direction. Under these conditions, the results given by the balances should be equally good during transient temperatures on five of the six components. The work will be used at the National Transonic Facility (NTF) at NASA Langley.

  1. TIGER: Development of Thermal Gradient Compensation Algorithms and Techniques

    NASA Technical Reports Server (NTRS)

    Hereford, James; Parker, Peter A.; Rhew, Ray D.

    2004-01-01

    In a wind tunnel facility, the direct measurement of forces and moments induced on the model are performed by a force measurement balance. The measurement balance is a precision-machined device that has strain gages at strategic locations to measure the strain (i.e., deformations) due to applied forces and moments. The strain gages convert the strain (and hence the applied force) to an electrical voltage that is measured by external instruments. To address the problem of thermal gradients on the force measurement balance NASA-LaRC has initiated a research program called TIGER - Thermally-Induced Gradients Effects Research. The ultimate goals of the TIGER program are to: (a) understand the physics of the thermally-induced strain and its subsequent impact on load measurements and (b) develop a robust thermal gradient compensation technique. This paper will discuss the impact of thermal gradients on force measurement balances, specific aspects of the TIGER program (the design of a special-purpose balance, data acquisition and data analysis challenges), and give an overall summary.

  2. Wind Tunnel Force Balance Calibration Study - Interim Results

    NASA Technical Reports Server (NTRS)

    Rhew, Ray D.

    2012-01-01

    Wind tunnel force balance calibration is preformed utilizing a variety of different methods and does not have a direct traceable standard such as standards used for most calibration practices (weights, and voltmeters). These different calibration methods and practices include, but are not limited to, the loading schedule, the load application hardware, manual and automatic systems, re-leveling and non-re-leveling. A study of the balance calibration techniques used by NASA was undertaken to develop metrics for reviewing and comparing results using sample calibrations. The study also includes balances of different designs, single and multi-piece. The calibration systems include, the manual, and the automatic that are provided by NASA and its vendors. The results to date will be presented along with the techniques for comparing the results. In addition, future planned calibrations and investigations based on the results will be provided.

  3. Continental-scale footprint of balancing and positive selection in a small rodent (Microtus arvalis).

    PubMed

    Fischer, Martin C; Foll, Matthieu; Heckel, Gerald; Excoffier, Laurent

    2014-01-01

    Genetic adaptation to different environmental conditions is expected to lead to large differences between populations at selected loci, thus providing a signature of positive selection. Whereas balancing selection can maintain polymorphisms over long evolutionary periods and even geographic scale, thus leads to low levels of divergence between populations at selected loci. However, little is known about the relative importance of these two selective forces in shaping genomic diversity, partly due to difficulties in recognizing balancing selection in species showing low levels of differentiation. Here we address this problem by studying genomic diversity in the European common vole (Microtus arvalis) presenting high levels of differentiation between populations (average F ST = 0.31). We studied 3,839 Amplified Fragment Length Polymorphism (AFLP) markers genotyped in 444 individuals from 21 populations distributed across the European continent and hence over different environmental conditions. Our statistical approach to detect markers under selection is based on a Bayesian method specifically developed for AFLP markers, which treats AFLPs as a nearly codominant marker system, and therefore has increased power to detect selection. The high number of screened populations allowed us to detect the signature of balancing selection across a large geographic area. We detected 33 markers potentially under balancing selection, hence strong evidence of stabilizing selection in 21 populations across Europe. However, our analyses identified four-times more markers (138) being under positive selection, and geographical patterns suggest that some of these markers are probably associated with alpine regions, which seem to have environmental conditions that favour adaptation. We conclude that despite favourable conditions in this study for the detection of balancing selection, this evolutionary force seems to play a relatively minor role in shaping the genomic diversity of the common vole, which is more influenced by positive selection and neutral processes like drift and demographic history.

  4. Identification of Balanced Chromosomal Rearrangements Previously Unknown Among Participants in the 1000 Genomes Project: Implications for Interpretation of Structural Variation in Genomes and the Future of Clinical Cytogenetics

    PubMed Central

    Dong, Zirui; Wang, Huilin; Chen, Haixiao; Jiang, Hui; Yuan, Jianying; Yang, Zhenjun; Wang, Wen-Jing; Xu, Fengping; Guo, Xiaosen; Cao, Ye; Zhu, Zhenzhen; Geng, Chunyu; Cheung, Wan Chee; Kwok, Yvonne K; Yang, Huangming; Leung, Tak Yeung; Morton, Cynthia C.; Cheung, Sau Wai; Choy, Kwong Wai

    2017-01-01

    Purpose Recent studies demonstrate that whole-genome sequencing (WGS) enables detection of cryptic rearrangements in apparently balanced chromosomal rearrangements (also known as balanced chromosomal abnormalities, BCAs) previously identified by conventional cytogenetic methods. We aimed to assess our analytical tool for detecting BCAs in The 1000 Genomes Project without knowing affected bands. Methods The 1000 Genomes Project provides an unprecedented integrated map of structural variants in phenotypically normal subjects, but there is no information on potential inclusion of subjects with apparently BCAs akin to those traditionally detected in diagnostic cytogenetics laboratories. We applied our analytical tool to 1,166 genomes from the 1000 Genomes Project with sufficient physical coverage (8.25-fold). Results Our approach detected four reciprocal balanced translocations and four inversions ranging in size from 57.9 kb to 13.3 Mb, all of which were confirmed by cytogenetic methods and PCR studies. One of DNAs has a subtle translocation that is not readily identified by chromosome analysis due to similar banding patterns and size of exchanged segments, and another results in disruption of all transcripts of an OMIM gene. Conclusions Our study demonstrates the extension of utilizing low-coverage WGS for unbiased detection of BCAs including translocations and inversions previously unknown in the 1000 Genomes Project. PMID:29095815

  5. Evaluation of the Orbitrap Mass Spectrometer for the Molecular Fingerprinting Analysis of Natural Dissolved Organic Matter.

    PubMed

    Hawkes, Jeffrey A; Dittmar, Thorsten; Patriarca, Claudia; Tranvik, Lars; Bergquist, Jonas

    2016-08-02

    We investigated the application of the LTQ-Orbitrap mass spectrometer (LTQ-Velos Pro, Thermo Fisher) for resolving complex mixtures of natural aquatic dissolved organic matter (DOM) and compared this technique to the more established state-of-the-art technique, Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS, Bruker Daltonics), in terms of the distribution of molecular masses detected and the reproducibility of the results collected. The Orbitrap was capable of excellent reproducibility: Bray-Curtis dissimilarity between duplicate measurements was 2.85 ± 0.42% (mean ± standard deviation). The Orbitrap was also capable of the detection of most major ionizable organic molecules in typical aquatic mixtures, with the exception of most sulfur and phosphorus containing masses. This result signifies that the Orbitrap is an appropriate technique for the investigation of very subtle biogeochemical processing of bulk DOM. The lower costs (purchase and maintenance) and wider availability of Orbitrap mass spectrometers in university departments means that the tools necessary for research into DOM processing at the molecular level should be accessible to a much wider group of scientists than before. The main disadvantage of the technique is that substantially fewer molecular formulas can be resolved from a complex mixture (roughly one third as many), meaning some loss of information. In balance, most biogeochemical studies that aim at molecularly fingerprinting the source of natural DOM could be satisfactorily carried out with Orbitrap mass spectrometry. For more targeted metabolomic studies where individual compounds are traced through natural systems, FTICR-MS remains advantageous.

  6. On-chip isothermal, chemical cycling polymerase chain reaction (ccPCR)

    NASA Astrophysics Data System (ADS)

    Persat, Alexandre; Santiago, Juan

    2008-11-01

    We demonstrate a novel ccPCR technique for microfluidic DNA amplification where temperature is held constant in space and time. The polymerase chain reaction is a platform of choice for biological assays and typically based on a three-step thermal cycling: DNA denaturation, primers annealing and extension by an enzyme. We here demonstrate a novel technique where high concentration chemical denaturants (solvents) denature DNA. We leverage the high electrophoretic mobility of DNA and the electrical neutrality of denaturants to achieve chemical cycling. We focus DNA with isotachophoresis (ITP); a robust electrophoretic preconcentration technique which generates strong electric field gradients and protects the sample from dispersion. We apply a pressure-driven flow to balance electromigration velocity and keep the DNA sample stationary in a microchannel. We drive the DNA through a series of high denaturant concentration zones. DNA denatures at high denaturant concentration. At low denaturant concentration, the enzyme creates complementary strands. DNA reaction kinetics are slower than buffer reactions involved in ITP. We demonstrate successful ccPCR amplification for detection of E. Coli. The ccPCR has the potential for simpler chemistry than traditional PCR.

  7. Monitoring Arctic Sea ice using ERTS imagery. [Bering Sea, Beaufort Sea, Canadian Archipelago, and Greenland Sea

    NASA Technical Reports Server (NTRS)

    Barnes, J. C.; Bowley, C. J.

    1974-01-01

    Because of the effect of sea ice on the heat balance of the Arctic and because of the expanding economic interest in arctic oil and other minerals, extensive monitoring and further study of sea ice is required. The application of ERTS data for mapping ice is evaluated for several arctic areas, including the Bering Sea, the eastern Beaufort Sea, parts of the Canadian Archipelago, and the Greenland Sea. Interpretive techniques are discussed, and the scales and types of ice features that can be detected are described. For the Bering Sea, a sample of ERTS imagery is compared with visual ice reports and aerial photography from the NASA CV-990 aircraft.

  8. Load Balancing in Structured P2P Networks

    NASA Astrophysics Data System (ADS)

    Zhu, Yingwu

    In this chapter we start by addressing the importance and necessity of load balancing in structured P2P networks, due to three main reasons. First, structured P2P networks assume uniform peer capacities while peer capacities are heterogeneous in deployed P2P networks. Second, resorting to pseudo-uniformity of the hash function used to generate node IDs and data item keys leads to imbalanced overlay address space and item distribution. Lastly, placement of data items cannot be randomized in some applications (e.g., range searching). We then present an overview of load aggregation and dissemination techniques that are required by many load balancing algorithms. Two techniques are discussed including tree structure-based approach and gossip-based approach. They make different tradeoffs between estimate/aggregate accuracy and failure resilience. To address the issue of load imbalance, three main solutions are described: virtual server-based approach, power of two choices, and address-space and item balancing. While different in their designs, they all aim to improve balance on the address space and data item distribution. As a case study, the chapter discusses a virtual server-based load balancing algorithm that strives to ensure fair load distribution among nodes and minimize load balancing cost in bandwidth. Finally, the chapter concludes with future research and a summary.

  9. AlGaN/GaN High Electron Mobility Transistor-Based Biosensor for the Detection of C-Reactive Protein

    PubMed Central

    Lee, Hee Ho; Bae, Myunghan; Jo, Sung-Hyun; Shin, Jang-Kyoo; Son, Dong Hyeok; Won, Chul-Ho; Jeong, Hyun-Min; Lee, Jung-Hee; Kang, Shin-Won

    2015-01-01

    In this paper, we propose an AlGaN/GaN high electron mobility transistor (HEMT)-based biosensor for the detection of C-reactive protein (CRP) using a null-balancing circuit. A null-balancing circuit was used to measure the output voltage of the sensor directly. The output voltage of the proposed biosensor was varied by antigen-antibody interactions on the gate surface due to CRP charges. The AlGaN/GaN HFET-based biosensor with null-balancing circuit applied shows that CRP can be detected in a wide range of concentrations, varying from 10 ng/mL to 1000 ng/mL. X-ray photoelectron spectroscopy was carried out to verify the immobilization of self-assembled monolayer with Au on the gated region. PMID:26225981

  10. Cryogenic strain gage techniques used in force balance design for the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Ferris, A. T.

    1986-01-01

    A force balance is a strain gage transducer used in wind tunnels to measure the forces and moments on aerodynamic models. Techniques have been established for temperature-compensation of force balances to allow their use over the operating temperature range of a cryogenic wind tunnel (-190C to 60C) without thermal control. This was accomplished by using a patented strain gage matching process to minimize inherent thermal differences, and a thermal compensation procedure to reduce the remaining thermally-induced outputs to acceptable levels. A method of compensating for mechanical movement of the axial force measuring beam caused by thermally-induced stresses under transient temperatures was also included.

  11. Balanced detection for self-mixing interferometry to improve signal-to-noise ratio

    NASA Astrophysics Data System (ADS)

    Zhao, Changming; Norgia, Michele; Li, Kun

    2018-01-01

    We apply balanced detection to self-mixing interferometry for displacement and vibration measurement, using two photodiodes for implementing a differential acquisition. The method is based on the phase opposition of the self-mixing signal measured between the two laser diode facet outputs. The balanced signal obtained by enlarging the self-mixing signal, also by canceling of the common-due noises mainly due to disturbances on laser supply and transimpedance amplifier. Experimental results demonstrate the signal-to-noise ratio significantly improves, with almost twice signals enhancement and more than half noise decreasing. This method allows for more robust, longer-distance measurement systems, especially using fringe-counting.

  12. A survey on investigating the need for intelligent power-aware load balanced routing protocols for handling critical links in MANETs.

    PubMed

    Sivakumar, B; Bhalaji, N; Sivakumar, D

    2014-01-01

    In mobile ad hoc networks connectivity is always an issue of concern. Due to dynamism in the behavior of mobile nodes, efficiency shall be achieved only with the assumption of good network infrastructure. Presence of critical links results in deterioration which should be detected in advance to retain the prevailing communication setup. This paper discusses a short survey on the specialized algorithms and protocols related to energy efficient load balancing for critical link detection in the recent literature. This paper also suggests a machine learning based hybrid power-aware approach for handling critical nodes via load balancing.

  13. A Survey on Investigating the Need for Intelligent Power-Aware Load Balanced Routing Protocols for Handling Critical Links in MANETs

    PubMed Central

    Sivakumar, B.; Bhalaji, N.; Sivakumar, D.

    2014-01-01

    In mobile ad hoc networks connectivity is always an issue of concern. Due to dynamism in the behavior of mobile nodes, efficiency shall be achieved only with the assumption of good network infrastructure. Presence of critical links results in deterioration which should be detected in advance to retain the prevailing communication setup. This paper discusses a short survey on the specialized algorithms and protocols related to energy efficient load balancing for critical link detection in the recent literature. This paper also suggests a machine learning based hybrid power-aware approach for handling critical nodes via load balancing. PMID:24790546

  14. Coarse-to-fine wavelet-based airport detection

    NASA Astrophysics Data System (ADS)

    Li, Cheng; Wang, Shuigen; Pang, Zhaofeng; Zhao, Baojun

    2015-10-01

    Airport detection on optical remote sensing images has attracted great interest in the applications of military optics scout and traffic control. However, most of the popular techniques for airport detection from optical remote sensing images have three weaknesses: 1) Due to the characteristics of optical images, the detection results are often affected by imaging conditions, like weather situation and imaging distortion; and 2) optical images contain comprehensive information of targets, so that it is difficult for extracting robust features (e.g., intensity and textural information) to represent airport area; 3) the high resolution results in large data volume, which makes real-time processing limited. Most of the previous works mainly focus on solving one of those problems, and thus, the previous methods cannot achieve the balance of performance and complexity. In this paper, we propose a novel coarse-to-fine airport detection framework to solve aforementioned three issues using wavelet coefficients. The framework includes two stages: 1) an efficient wavelet-based feature extraction is adopted for multi-scale textural feature representation, and support vector machine(SVM) is exploited for classifying and coarsely deciding airport candidate region; and then 2) refined line segment detection is used to obtain runway and landing field of airport. Finally, airport recognition is achieved by applying the fine runway positioning to the candidate regions. Experimental results show that the proposed approach outperforms the existing algorithms in terms of detection accuracy and processing efficiency.

  15. Development of image analysis techniques as a tool to detect and quantify morphological changes in anaerobic sludge: I. Application to a granulation process.

    PubMed

    Araya-Kroff, P; Amaral, A L; Neves, L; Ferreira, E C; Pons, M-N; Mota, M; Alves, M M

    2004-07-20

    Image analysis techniques were developed and applied to quantify the process of anaerobic granulation in an expanded granular sludge blanket reactor (EGSB) fed with a synthetic substrate based on glucose [60-30% COD (chemical oxygen demand)] and volatile fatty acids (40-70% COD) over 376 days. In a first operation period that lasted 177 days, the aggregation of dispersed sludge was quantitatively monitored through the recognition and quantification of aggregates and filaments. A parameter defined as the ratio between the filaments' length and the aggregates projected area (LfA) has proven to be sensitive to detect changes in the aggregation status of the anaerobic sludge. The aggregation time-defined as the moment when a balance between filaments' length and aggregates' size was established-was recognized through the LfA. The percentage of projected area of aggregates within three size ranges (0.01-0.1 mm, 0.1-1 mm, and >1 mm, equivalent diameter) reflected the granular size spectrum during the aggregation process. When sudden increases on the upflow velocity and on the organic loading rate were applied to the previously formed granules, the developed image analysis techniques revealed to be good indicators of granular sludge stability, since they were sensitive to detected filaments release, fragmentation, and erosion that usually leads to washout. The specific methanogenic activities in the presence of acetate, propionate, butyrate, and H(2)/CO(2) increased along the operation, particularly relevant was the sudden increase in the specific hydrogenophilic activity, immediately after the moment recognized as aggregation time. Copyright 2004 Wiley Periodicals, Inc.

  16. A novel quantitative analysis method of three-dimensional fluorescence spectra for vegetable oils contents in edible blend oil

    NASA Astrophysics Data System (ADS)

    Xu, Jing; Wang, Yu-Tian; Liu, Xiao-Fei

    2015-04-01

    Edible blend oil is a mixture of vegetable oils. Eligible blend oil can meet the daily need of two essential fatty acids for human to achieve the balanced nutrition. Each vegetable oil has its different composition, so vegetable oils contents in edible blend oil determine nutritional components in blend oil. A high-precision quantitative analysis method to detect the vegetable oils contents in blend oil is necessary to ensure balanced nutrition for human being. Three-dimensional fluorescence technique is high selectivity, high sensitivity, and high-efficiency. Efficiency extraction and full use of information in tree-dimensional fluorescence spectra will improve the accuracy of the measurement. A novel quantitative analysis is proposed based on Quasi-Monte-Carlo integral to improve the measurement sensitivity and reduce the random error. Partial least squares method is used to solve nonlinear equations to avoid the effect of multicollinearity. The recovery rates of blend oil mixed by peanut oil, soybean oil and sunflower are calculated to verify the accuracy of the method, which are increased, compared the linear method used commonly for component concentration measurement.

  17. Rapidly Assessing Changes in Bone Mineral Balance Using Natural Stable Calcium Isotopes

    NASA Technical Reports Server (NTRS)

    Morgan, J. L. L.; Gordon, G. W.; Romaniello, S. J.; Skulan, J. L.; Smith, S. M.; Anbar, A. D.

    2011-01-01

    We demonstrate that variations in the Ca isotope ratios in urine rapidly and quantitatively reflect changes in bone mineral balance. This variation occurs because bone formation depletes soft tissue of light Ca isotopes, while bone resorption releases that isotopically light Ca back into soft tissue. In a study of 12 individuals confined to bed rest, a condition known to induce bone resorption, we show that Ca isotope ratios shift in a direction consistent with net bone loss after just 7 days, long before detectible changes in bone density occur. Consistent with this interpretation, the Ca isotope variations track changes observed in N-teleopeptide, a bone resorption biomarker, while bone-specific alkaline phosphatase, a bone formation biomarker, is unchanged. Ca isotopes can in principle be used to quantify net changes in bone mass. Ca isotopes indicate an average loss of 0.62 +/- 0.16 % in bone mass over the course of this 30-day study. The Ca isotope technique should accelerate the pace of discovery of new treatments for bone disease and provide novel insights into the dynamics of bone metabolism.

  18. Leak detection in gas pipeline by acoustic and signal processing - A review

    NASA Astrophysics Data System (ADS)

    Adnan, N. F.; Ghazali, M. F.; Amin, M. M.; Hamat, A. M. A.

    2015-12-01

    The pipeline system is the most important part in media transport in order to deliver fluid to another station. The weak maintenance and poor safety will contribute to financial losses in term of fluid waste and environmental impacts. There are many classifications of techniques to make it easier to show their specific method and application. This paper's discussion about gas leak detection in pipeline system using acoustic method will be presented in this paper. The wave propagation in the pipeline is a key parameter in acoustic method when the leak occurs and the pressure balance of the pipe will generated by the friction between wall in the pipe. The signal processing is used to decompose the raw signal and show in time- frequency. Findings based on the acoustic method can be used for comparative study in the future. Acoustic signal and HHT is the best method to detect leak in gas pipelines. More experiments and simulation need to be carried out to get the fast result of leaking and estimation of their location.

  19. Load balancing for massively-parallel soft-real-time systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hailperin, M.

    1988-09-01

    Global load balancing, if practical, would allow the effective use of massively-parallel ensemble architectures for large soft-real-problems. The challenge is to replace quick global communications, which is impractical in a massively-parallel system, with statistical techniques. In this vein, the author proposes a novel approach to decentralized load balancing based on statistical time-series analysis. Each site estimates the system-wide average load using information about past loads of individual sites and attempts to equal that average. This estimation process is practical because the soft-real-time systems of interest naturally exhibit loads that are periodic, in a statistical sense akin to seasonality in econometrics.more » It is shown how this load-characterization technique can be the foundation for a load-balancing system in an architecture employing cut-through routing and an efficient multicast protocol.« less

  20. Natural calcium isotonic composition of urine as a marker of bone mineral balance

    USGS Publications Warehouse

    Skulan, J.; Bullen, T.; Anbar, A.D.; Puzas, J.E.; Shackelford, L.; LeBlanc, A.; Smith, S.M.

    2007-01-01

    Background: We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Methods: Calcium isotopic compositions are expressed as ??44Ca, or the difference in parts per thousand between the 44Ca/40Ca of a sample and the 44Ca/ 40Ca of a standard reference material. ??44Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Results: Urine ??44Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, Mest). Results were consistent with the model and with biochemical and bone mineral density data. Conclusion: Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool. ?? 2007 American Association for Clinical Chemistry.

  1. Semimembranosus Release for Medial Soft Tissue Balancing Does Not Weaken Knee Flexion Strength in Patients Undergoing Varus Total Knee Arthroplasty.

    PubMed

    Jang, Sung Won; Koh, In Jun; Kim, Man Soo; Kim, Ju Yeong; In, Yong

    2016-11-01

    The sequential medial release technique including semimembranosus (semiM) release is effective and safe during varus total knee arthroplasty (TKA). However, there are concerns about weakening of knee flexion strength after semiM release. We determined whether semiM release to balance the medial soft tissue decreased knee flexion strength after TKA. Fifty-nine consecutive varus knees undergoing TKA were prospectively enrolled. A 3-step sequential release protocol which consisted of release of (1) the deep medial collateral ligament (dMCL), (2) the semiM, and (3) the superficial medial collateral ligament based on medial tightness. Gap balancing was obtained after dMCL release in 31 knees. However, 28 knees required semiM release or more after dMCL release. Isometric muscle strength of the knee was compared 6 months postoperatively between the semiM release and semiM nonrelease groups. Knee stability and clinical outcomes were also compared. No differences in knee flexor or extensor peak torque were observed between the groups 6 months postoperatively (P = .322 and P = .383, respectively). No group difference was observed in medial joint opening angle on valgus stress radiographs (P = .327). No differences in the Knee Society or Western Ontario and McMaster Universities Osteoarthritis Index scores were detected between the groups (P = .840 and P = .682, respectively). These results demonstrate that semiM release as a sequential step to balance medial soft tissue in varus knees did not affect knee flexion strength after TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Natural calcium isotopic composition of urine as a marker of bone mineral balance.

    PubMed

    Skulan, Joseph; Bullen, Thomas; Anbar, Ariel D; Puzas, J Edward; Shackelford, Linda; LeBlanc, Adrian; Smith, Scott M

    2007-06-01

    We investigated whether changes in the natural isotopic composition of calcium in human urine track changes in net bone mineral balance, as predicted by a model of calcium isotopic behavior in vertebrates. If so, isotopic analysis of natural urine or blood calcium could be used to monitor short-term changes in bone mineral balance that cannot be detected with other techniques. Calcium isotopic compositions are expressed as delta(44)Ca, or the difference in parts per thousand between the (44)Ca/(40)Ca of a sample and the (44)Ca/(40)Ca of a standard reference material. delta(44)Ca was measured in urine samples from 10 persons who participated in a study of the effectiveness of countermeasures to bone loss in spaceflight, in which 17 weeks of bed rest was used to induce bone loss. Study participants were assigned to 1 of 3 treatment groups: controls received no treatment, one treatment group received alendronate, and another group performed resistive exercise. Measurements were made on urine samples collected before, at 2 or 3 points during, and after bed rest. Urine delta(44)Ca values during bed rest were lower in controls than in individuals treated with alendronate (P <0.05, ANOVA) or exercise (P <0.05), and lower than the control group baseline (P <0.05, t-test). Results were consistent with the model and with biochemical and bone mineral density data. Results confirm the predicted relationship between bone mineral balance and calcium isotopes, suggesting that calcium isotopic analysis of urine might be refined into a clinical and research tool.

  3. Research on measurement of aviation magneto ignition strength and balance

    NASA Astrophysics Data System (ADS)

    Gao, Feng; He, Zhixiang; Zhang, Dingpeng

    2017-12-01

    Aviation magneto ignition system failure accounted for two-thirds of the total fault aviation piston engine and above. At present the method used for this failure diagnosis is often depended on the visual inspections in the civil aviation maintenance field. Due to human factors, the visual inspections cannot provide ignition intensity value and ignition equilibrium deviation value among the different spark plugs in the different cylinder of aviation piston engine. So air magneto ignition strength and balance testing has become an aviation piston engine maintenance technical problem needed to resolve. In this paper, the ultraviolet sensor with detection wavelength of 185~260nm and driving voltage of 320V DC is used as the core of ultraviolet detection to detect the ignition intensity of Aviation magneto ignition system and the balance deviation of the ignition intensity of each cylinder. The experimental results show that the rotational speed within the range 0 to 3500 RPM test error less than 0.34%, ignition strength analysis and calculation error is less than 0.13%, and measured the visual inspection is hard to distinguish between high voltage wire leakage failure of deviation value of 200 pulse ignition strength balance/Sec. The method to detect aviation piston engine maintenance of magneto ignition system fault has a certain reference value.

  4. In vivo stationary flux analysis by 13C labeling experiments.

    PubMed

    Wiechert, W; de Graaf, A A

    1996-01-01

    Stationary flux analysis is an invaluable tool for metabolic engineering. In the last years the metabolite balancing technique has become well established in the bioengineering community. On the other hand metabolic tracer experiments using 13C isotopes have long been used for intracellular flux determination. Only recently have both techniques been fully combined to form a considerably more powerful flux analysis method. This paper concentrates on modeling and data analysis for the evaluation of such stationary 13C labeling experiments. After reviewing recent experimental developments, the basic equations for modeling carbon labeling in metabolic systems, i.e. metabolite, carbon label and isotopomer balances, are introduced and discussed in some detail. Then the basics of flux estimation from measured extracellular fluxes combined with carbon labeling data are presented and, finally, this method is illustrated by using an example from C. glutamicum. The main emphasis is on the investigation of the extra information that can be obtained with tracer experiments compared with the metabolite balancing technique alone. As a principal result it is shown that the combined flux analysis method can dispense with some rather doubtful assumptions on energy balancing and that the forward and backward flux rates of bidirectional reaction steps can be simultaneously determined in certain situations. Finally, it is demonstrated that the variant of fractional isotopomer measurement is even more powerful than fractional labeling measurement but requires much higher numerical effort to solve the balance equations.

  5. Improvements in balance control in individuals with PCS detected following vestibular training: A case study.

    PubMed

    Prangley, Alyssa; Aggerholm, Mathew; Cinelli, Michael

    2017-10-01

    Concussed individuals have been found to experience balance deficits in the anterior-posterior (AP) direction as indicated by greater Center of Pressure (COP) displacement and velocity. One possible reason for this change in balance control could be due to damage to the lateral vestibulospinal tract which sends signals to control posterior muscles, specifically ankle extensors leading to compensatory torques about the ankle. The purpose of the study was to quantify balance assessments in individuals experiencing persistent post-concussion symptoms (PCS) to determine balance control changes following a vestibular training intervention. Participants (N=6,>26days symptomatic), were tested during their first appointment with a registered physiotherapist (PT) and during each follow up appointment. Participants were prescribed balance, visual, and neck strengthening exercises by the PT that were to be completed daily between bi-weekly appointments. Balance assessments were quantified using a Nintendo Wii board to record ground reaction forces. Participants completed 4 balance assessments: 1) Romberg stance eyes open (REO); 2) Romberg stance eyes closed (REC); 3) single leg stance eyes open (SEO); and 4) single leg stance eyes closed (SEC). The balance assessments were conducted on both a firm and compliant surfaces. Significant improvements in balance control were noted in ML/AP displacement and velocity of COP for both SEC and Foam REC conditions, with additional improvements in AP velocity of COP for Foam REC and in ML displacement of COP during Foam SEC. Overall, findings indicate that objectively quantifying balance changes for individuals experiencing persistent PCS allows for a more sensitive measure of balance and detects changes unrecognizable to the naked eye. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Balancing Conflicting Requirements for Grid and Particle Decomposition in Continuum-Lagrangian Solvers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sitaraman, Hariswaran; Grout, Ray

    2015-10-30

    The load balancing strategies for hybrid solvers that involve grid based partial differential equation solution coupled with particle tracking are presented in this paper. A typical Message Passing Interface (MPI) based parallelization of grid based solves are done using a spatial domain decomposition while particle tracking is primarily done using either of the two techniques. One of the techniques is to distribute the particles to MPI ranks to whose grid they belong to while the other is to share the particles equally among all ranks, irrespective of their spatial location. The former technique provides spatial locality for field interpolation butmore » cannot assure load balance in terms of number of particles, which is achieved by the latter. The two techniques are compared for a case of particle tracking in a homogeneous isotropic turbulence box as well as a turbulent jet case. We performed a strong scaling study for more than 32,000 cores, which results in particle densities representative of anticipated exascale machines. The use of alternative implementations of MPI collectives and efficient load equalization strategies are studied to reduce data communication overheads.« less

  7. Implementation of GAMMON - An efficient load balancing strategy for a local computer system

    NASA Technical Reports Server (NTRS)

    Baumgartner, Katherine M.; Kling, Ralph M.; Wah, Benjamin W.

    1989-01-01

    GAMMON (Global Allocation from Maximum to Minimum in cONstant time), an efficient load-balancing algorithm, is described. GAMMON uses the available broadcast capability of multiaccess networks to implement an efficient search technique for finding hosts with maximal and minimal loads. The search technique has an average overhead which is independent of the number of participating stations. The transition from the theoretical concept to a practical, reliable, and efficient implementation is described.

  8. Balancing techniques for high-speed flexible rotors

    NASA Technical Reports Server (NTRS)

    Smalley, A. J.

    1978-01-01

    Ideal and non-ideal conditions for multiplane balancing are addressed. Methodology and procedures for identifying optimum balancing configurations and for assessing, quantitatively, the penalties associated with non-optimum configurations were developed and demonstrated. The problems introduced when vibration sensors are supported on flexible mounts were assessed experimentally, and the effects of flexural asymmetry in the rotor on balancing were investigated. A general purpose method for predicting the threshold of instability of an asymmetric rotor was developed, and its predictions are compared with measurements under different degrees of asymmetry.

  9. Radiation balances and the solar constant

    NASA Technical Reports Server (NTRS)

    Crommelynck, D.

    1981-01-01

    The radiometric concepts are defined in order to consider various types of radiation balances and relate them to the diabetic form of the energy balance. Variability in space and time of the components of the radiation field are presented. A specific concept for sweeping which is tailored to the requirements is proposed. Finally, after establishing the truncated character of the present knowledge of the radiation balance. The results of the last observations of the solar constant are given. Ground and satellite measurement techniques are discussed.

  10. Customized Knee Prosthesis in Treatment of Giant Cell Tumors of the Proximal Tibia: Application of 3-Dimensional Printing Technology in Surgical Design.

    PubMed

    Luo, Wenbin; Huang, Lanfeng; Liu, He; Qu, Wenrui; Zhao, Xin; Wang, Chenyu; Li, Chen; Yu, Tao; Han, Qing; Wang, Jincheng; Qin, Yanguo

    2017-04-07

    BACKGROUND We explored the application of 3-dimensional (3D) printing technology in treating giant cell tumors (GCT) of the proximal tibia. A tibia block was designed and produced through 3D printing technology. We expected that this 3D-printed block would fill the bone defect after en-bloc resection. Importantly, the block, combined with a standard knee joint prosthesis, provided attachments for collateral ligaments of the knee, which can maintain knee stability. MATERIAL AND METHODS A computed tomography (CT) scan was taken of both knee joints in 4 patients with GCT of the proximal tibia. We developed a novel technique - the real-size 3D-printed proximal tibia model - to design preoperative treatment plans. Hence, with the application of 3D printing technology, a customized proximal tibia block could be designed for each patient individually, which fixed the bone defect, combined with standard knee prosthesis. RESULTS In all 4 cases, the 3D-printed block fitted the bone defect precisely. The motion range of the affected knee was 90 degrees on average, and the soft tissue balance and stability of the knee were good. After an average 7-month follow-up, the MSTS score was 19 on average. No sign of prosthesis fracture, loosening, or other relevant complications were detected. CONCLUSIONS This technique can be used to treat GCT of the proximal tibia when it is hard to achieve soft tissue balance after tumor resection. 3D printing technology simplified the design and manufacturing progress of custom-made orthopedic medical instruments. This new surgical technique could be much more widely applied because of 3D printing technology.

  11. Behavioral determination of stimulus pair discrimination of auditory acoustic and electrical stimuli using a classical conditioning and heart-rate approach.

    PubMed

    Morgan, Simeon J; Paolini, Antonio G

    2012-06-06

    Acute animal preparations have been used in research prospectively investigating electrode designs and stimulation techniques for integration into neural auditory prostheses, such as auditory brainstem implants and auditory midbrain implants. While acute experiments can give initial insight to the effectiveness of the implant, testing the chronically implanted and awake animals provides the advantage of examining the psychophysical properties of the sensations induced using implanted devices. Several techniques such as reward-based operant conditioning, conditioned avoidance, or classical fear conditioning have been used to provide behavioral confirmation of detection of a relevant stimulus attribute. Selection of a technique involves balancing aspects including time efficiency (often poor in reward-based approaches), the ability to test a plurality of stimulus attributes simultaneously (limited in conditioned avoidance), and measure reliability of repeated stimuli (a potential constraint when physiological measures are employed). Here, a classical fear conditioning behavioral method is presented which may be used to simultaneously test both detection of a stimulus, and discrimination between two stimuli. Heart-rate is used as a measure of fear response, which reduces or eliminates the requirement for time-consuming video coding for freeze behaviour or other such measures (although such measures could be included to provide convergent evidence). Animals were conditioned using these techniques in three 2-hour conditioning sessions, each providing 48 stimulus trials. Subsequent 48-trial testing sessions were then used to test for detection of each stimulus in presented pairs, and test discrimination between the member stimuli of each pair. This behavioral method is presented in the context of its utilisation in auditory prosthetic research. The implantation of electrocardiogram telemetry devices is shown. Subsequent implantation of brain electrodes into the Cochlear Nucleus, guided by the monitoring of neural responses to acoustic stimuli, and the fixation of the electrode into place for chronic use is likewise shown.

  12. 75 FR 70096 - Airworthiness Directives; General Electric Company (GE) CT7-9C and -9C3 Turboprop Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-17

    ... generator turbine (GGT) shafts for nonconforming land balance-cuts, and if found, removing the shaft from... detect nonconforming GGT shaft land balance-cuts, which could result in the shaft failing before its..., for nonconforming land balance- cuts, and if found, replacing the shaft. Comments We gave the public...

  13. Can we detect national-scale under-reporting of CO2 emissions using OCO-2 XCO2 observations in a carbon-weather data assimilation system?

    NASA Astrophysics Data System (ADS)

    Wuerth, S. M.; Fung, I. Y.; Anderson, J. L.; Raeder, K.

    2016-12-01

    A long-standing challenge in carbon cycle science is the inference of surface fluxes from atmospheric CO2 observations. Here we present initial results from our carbon-weather data assimilation system coupled to a mass-balance inversion . Our system combines the Community Atmosphere Model (CAM 5FV) with state-of-the-art ensemble data assimilation techniques from the Data Assimilation Research Testbed (DART), and assimilates OCO-2 XCO2 observations together with raw meteorological observations. The system uses a mass balance of the optimized atmospheric state to calculate CO2 sources and sinks throughout the globe. We present results from observing system simulation experiments (OSSE) aimed at comparing two different mass-balance approaches' abilities to detect under-reporting of national-scale CO2 emissions. In both experiments, we define a true state as the atmospheric state resulting from running CAM with a prognostic carbon cycle and CO2 emissions from CarbonTracker CT2015. Meteorological and OCO-2-like observations are harvested from this true state for assimilation. We create a hypothetical scenario in which fossil fuel CO2 emissions of a large emitter are scaled to half of their true values. Surface fluxes are then estimated using one of two approaches. The first approach computes, at every 6-hourly assimilation window, surface fluxes as the residual in the mass balance equation after divergence has been accounted for. The updated surface fluxes are then used as forcing in the ensuing CAM forecast. The second approach uses the initial false emissions for two weeks of model integration, then computes improved emissions by adding the time-averaged analysis increment in near-surface CO2 mixing ratio to the initial false emissions. The two weeks are re-run with these updated fluxes, and the process is then repeated for further refinement of fluxes. The advantages and disadvantages of the two approaches are discussed, and the system's ability to recover the true fluxes is assessed.

  14. Watt and joule balances

    NASA Astrophysics Data System (ADS)

    Robinson, Ian A.

    2014-04-01

    The time is fast approaching when the SI unit of mass will cease to be based on a single material artefact and will instead be based upon the defined value of a fundamental constant—the Planck constant—h . This change requires that techniques exist both to determine the appropriate value to be assigned to the constant, and to measure mass in terms of the redefined unit. It is important to ensure that these techniques are accurate and reliable to allow full advantage to be taken of the stability and universality provided by the new definition and to guarantee the continuity of the world's mass measurements, which can affect the measurement of many other quantities such as energy and force. Up to now, efforts to provide the basis for such a redefinition of the kilogram were mainly concerned with resolving the discrepancies between individual implementations of the two principal techniques: the x-ray crystal density (XRCD) method [1] and the watt and joule balance methods which are the subject of this special issue. The first three papers report results from the NRC and NIST watt balance groups and the NIM joule balance group. The result from the NRC (formerly the NPL Mk II) watt balance is the first to be reported with a relative standard uncertainty below 2 × 10-8 and the NIST result has a relative standard uncertainty below 5 × 10-8. Both results are shown in figure 1 along with some previous results; the result from the NIM group is not shown on the plot but has a relative uncertainty of 8.9 × 10-6 and is consistent with all the results shown. The Consultative Committee for Mass and Related Quantities (CCM) in its meeting in 2013 produced a resolution [2] which set out the requirements for the number, type and quality of results intended to support the redefinition of the kilogram and required that there should be agreement between them. These results from NRC, NIST and the IAC may be considered to meet these requirements and are likely to be widely debated prior to a decision on redefinition. The CCM had already recognized that agreement was close and has set in place a process whereby redefinition can take place by 2018. The final decision will be in the hands of the Conférence Générale des Poids et Mesures (CGPM) but the results reported here should aid a positive decision. Figure 1. Figure 1. Results from recent measurements of the Planck constant. The reference for the results h 90 is derived from the conventional values of the Josephson constant K J-90 and the von Klitzing constant R K-90. The factor of ten improvement in uncertainty of the NRC watt balance result, over that achieved by the same apparatus at NPL a few years earlier, can be understood as a factor of five improvement arising from the elimination of an effect discovered at NPL that could not be eliminated before shipment to Canada and a factor of two arising from the considerable improvements made by NRC. Once the kilogram has been redefined, the watt and joule balances will complete their transitions from instruments that are primarily of interest to the electrical community for determining the SI electrical units from the mechanical units, to the principal methods by which an individual National Measurement Institute (NMI) can make an independent determination of the SI unit of mass and thereby contribute to the maintenance of national and international mass scales. This special issue gives an introduction to the diversity of techniques which are required for the operation of watt and joule balances. However it does not contain a review of existing balances; this was a deliberate decision, as a number of such review papers have been published in the past five years [3-7] and it was felt that it was not yet time for another. The first technique considered is that of gravimetry; the watt balance measures the weight Mg of a mass M , and to convert the measured weight into a mass, the value of the acceleration due to gravity g must be known, at the time of the weighing and at the centre of gravity of the mass. The paper by Liard and his co-authors at NRC describes how they have made this essential measurement. The accuracy of the watt balance may also depend on the alignment of the apparatus. Two papers deal with this important issue. The first, by Sanchez and his co-authors at NRC, shows that their balance is insensitive to a range of alignments and concentrates on the essential alignments that contribute directly to the overall uncertainty of the apparatus. Thomas and his co-authors at LNE describe their technique for reducing uncertainties in their watt balance by aligning its coil in the field of the magnet to minimize both horizontal forces and torques about horizontal axes. The search for discrepancies between the results from watt balances has encouraged researchers to consider possible error mechanisms arising from the secondary electrical interactions between the coil of a watt balance and other parts of the apparatus. Researchers from INRIM have two such papers: one considering magnetic interactions and the other considering electrostatic interactions. It is essential that such investigations are carried out: both to prove that the problems are understood and for the guidance of those building the next generation of watt and joule balances. The next four papers describe aspects of the construction of watt balances. The BIPM watt balance group describe the principles behind their simultaneous measurement scheme for a watt balance. The balance that they are constructing can also be used in the conventional two-phase mode and their paper describes the relative advantages and disadvantages of the two modes of operation. In a watt balance there are some advantages to precise vertical movement of the coil. The METAS group describe the two mechanisms that they have tested to achieve such motion and give the reasons for the choice of mechanism for use in the balance that they are constructing. The KRISS watt balance group are in the initial phases of the design and construction of a watt balance and their paper provides valuable information on the design that they are building. The design of the main magnet of a watt balance is critical to its successful operation, and an important assumption of watt balance operation is that the field of the magnet in moving mode is equivalent to that in weighing mode. Sutton and Clarkson from MSL describe a novel magnet which is designed to address this issue. The international prototype of the kilogram is kept in air but, after redefinition, the best realizations of the mass unit will be in vacuum. In their paper Berry and Davidson from NPL describe progress in techniques which relate mass measured in vacuum to that measured in air. Such techniques will be essential for making the results of watt and joule balance measurements available to science and industry. Both the NIST and NPL Mark II (NRC) watt balances use knife edges to act as the pivots for the beam. Knife edges suffer from hysteresis which can produce systematic offsets during weighing. In their paper Choi (KRISS) and Robinson (NPL) describe the analysis of this problem using both finite element (FEM) techniques and a stand-alone balance designed for testing knife edges. The last two papers deal with the possible future of the watt balance technique. The BIPM simultaneous measurement scheme for the watt balance was originally conceived for operation at cryogenic temperatures with a superconducting coil. In their paper de Mirandes and her co-authors describe initial work on the principles of this superconducting variant of the BIPM watt balance and concentrate on the characteristics of the superconducting coil in comparison with those of a normal coil. The final paper is a good example of serendipity in which Kibble (Independent Consultant) was designing novel watt balances based on seismometer suspensions and Robinson (NPL) had derived a set of general expressions, which are required for a watt balance to be immune to a range of common misalignments but also lead to the design of watt balances with a range of coil motions. The combination of these techniques has led to the novel watt balance designs which are described. Finally I would like to thank: the editor of Metrologia and the editorial staff of IOP Publishing, the referees who have responded rapidly to requests and have kept the issue on schedule, and the authors who have taken the time to provide a range of papers showing the breadth of the work required to build and operate watt or joule balances. References [1] Andreas B et al 2011 Determination of the Avogadro constant by counting the atoms in a 28Si crystal Phys. Rev. Lett. 106 030801 [2] BIPM 2013 Report of the 14th Meeting of the CCM Sèvres pp 34-7 [3] Steiner R 2013 History and progress on accurate measurements of the Planck constant Rep. Prog. Phys. 76 016101 [4] Stock M 2013 Watt balance experiments for the determination of the Planck constant and the redefinition of the kilogram Metrologia 50 R1-16 [5] Li S, Han B, Li Z and Lan J 2012 Precisely measuring the Planck constant by electromechanical balances Measurement 45 1-13 [6] Eichenberger A, Genevès G and Gournay P 2009 Determination of the Planck constant by means of a watt balance Eur. Phys. J. Spec. Top. 172 363-83 [7] Robinson I A 2009 Toward the redefinition of the kilogram: measurements of Planck's constant using watt balances IEEE Trans. Instrum. Meas. 58 942-8

  15. Natural Ca Isotope Composition of Urine as a Rapid Measure of Bone Mineral Balance

    NASA Astrophysics Data System (ADS)

    Skulan, J.; Gordon, G. W.; Morgan, J.; Romaniello, S. J.; Smith, S. M.; Anbar, A. D.

    2011-12-01

    Naturally occurring stable Ca isotope variations in urine are emerging as a powerful tool to detect changes in bone mineral balance. Bone formation depletes soft tissue of light Ca isotopes while bone resorption releases isotopically light Ca into soft tissue. Previously published work found that variations in Ca isotope composition could be detected at 4 weeks of bed rest in a 90-day bed rest study (data collected at 4, 8 and 12 weeks). A new 30-day bed rest study involved 12 patients on a controlled diet, monitored for 7 days prior to bed rest and 7 days post bed rest. Samples of urine, blood and food were collected throughout the study. Four times daily blood samples and per void urine samples were collected to monitor diurnal or high frequency variations. An improved chemical purification protocol, followed by measurement using multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) allowed accurate and precise determinations of mass-dependent Ca isotope variations in these biological samples to better than ±0.2% (δ44/42Ca) on <25 μg of Ca. Results from this new study show that Ca isotope ratios shift in a direction consistent with net bone loss after just 7 days, long before detectible changes in bone density by X-ray measurements occur. Consistent with this interpretation, the Ca isotope variations track changes observed in N-teleopeptide, a bone resorption biomarker. Bone-specific alkaline phosphatase, a bone formation biomarker, is unchanged over this period. Ca isotopes can in principle be used to quantify net changes in bone mass. Using a mass-balance model, our results indicate an average loss of 0.62 ± 0.16 % in bone mass over the course of this 30-day study. This is consistent with the rate of bone loss in longer-term studies as seen by X-ray measurements. This Ca isotope technique should accelerate the pace of discovery of new treatments for bone disease and provide novel insights into the dynamics of bone metabolism.

  16. Micrometeorological Mass Balance Measurements of Greenhouse Gas Emissions from Composting Green-waste

    NASA Astrophysics Data System (ADS)

    Kent, E. R.; Bailey, S.; Stephens, J.; Horwath, W. R.; Paw U, K.

    2013-12-01

    Managed decomposition of organic materials is increasingly being used as an alternative waste management option and the resulting compost can be used as a fertilizer and soil amendment in home gardens and agriculture. An additional benefit is the avoidance of methane emissions associated with anaerobic decomposition in landfills. Greenhouse gases are still emitted during the composting process, but few studies have measured emissions from a full-scale windrow of composting green-waste. This study uses a micrometeorological mass balance technique (upwind and downwind vertical profile measurements of trace gas concentrations and wind velocity) to calculate emissions of carbon dioxide, methane, and nitrous oxide from a pile of composting green-waste during the dry season in Northern California. The expected source pattern was observed in measured upwind-downwind concentration differences of all three gases averaged over the study period despite substantial noise seen in the half-hourly emission calculations. Sources of uncertainty are investigated and temporal patterns analyzed. An in-situ zero-source test was conducted to examine the mass balance technique when the source of emissions was removed. Results from the micrometeorological mass balance measurements are compared with measurements taken using the more common open chamber technique.

  17. Load Balancing Using Time Series Analysis for Soft Real Time Systems with Statistically Periodic Loads

    NASA Technical Reports Server (NTRS)

    Hailperin, M.

    1993-01-01

    This thesis provides design and analysis of techniques for global load balancing on ensemble architectures running soft-real-time object-oriented applications with statistically periodic loads. It focuses on estimating the instantaneous average load over all the processing elements. The major contribution is the use of explicit stochastic process models for both the loading and the averaging itself. These models are exploited via statistical time-series analysis and Bayesian inference to provide improved average load estimates, and thus to facilitate global load balancing. This thesis explains the distributed algorithms used and provides some optimality results. It also describes the algorithms' implementation and gives performance results from simulation. These results show that the authors' techniques allow more accurate estimation of the global system loading, resulting in fewer object migrations than local methods. The authors' method is shown to provide superior performance, relative not only to static load-balancing schemes but also to many adaptive load-balancing methods. Results from a preliminary analysis of another system and from simulation with a synthetic load provide some evidence of more general applicability.

  18. Battery voltage-balancing applications of disk-type radial mode Pb(Zr • Ti)O3 ceramic resonator

    NASA Astrophysics Data System (ADS)

    Thenathayalan, Daniel; Lee, Chun-gu; Park, Joung-hu

    2017-10-01

    In this paper, we propose a novel technique to build a charge-balancing circuit for series-connected battery strings using various kinds of disk-type ceramic Pb(Zr • Ti)O3 piezoelectric resonators (PRs). The use of PRs replaces the whole external battery voltage-balancer circuit, which consists mainly of a bulky magnetic element. The proposed technique is validated using different ceramic PRs and the results are analyzed in terms of their physical properties. A series-connected battery string with a voltage rating of 61.5 V is set as a hardware prototype under test, then the power transfer efficiency of the system is measured at different imbalance voltages. The performance of the proposed battery voltage-balancer circuit employed with a PR is also validated through hardware implementation. Furthermore, the temperature distribution image of the PR is obtained to compare power transfer efficiency and thermal stress under different operating conditions. The test results show that the battery voltage-balancer circuit can be successfully implemented using PRs with the maximum power conversion efficiency of over 96% for energy storage systems.

  19. The impact of detergents on the tissue decellularization process: A ToF-SIMS study.

    PubMed

    White, Lisa J; Taylor, Adam J; Faulk, Denver M; Keane, Timothy J; Saldin, Lindsey T; Reing, Janet E; Swinehart, Ilea T; Turner, Neill J; Ratner, Buddy D; Badylak, Stephen F

    2017-03-01

    Biologic scaffolds are derived from mammalian tissues, which must be decellularized to remove cellular antigens that would otherwise incite an adverse immune response. Although widely used clinically, the optimum balance between cell removal and the disruption of matrix architecture and surface ligand landscape remains a considerable challenge. Here we describe the use of time of flight secondary ion mass spectroscopy (ToF-SIMS) to provide sensitive, molecular specific, localized analysis of detergent decellularized biologic scaffolds. We detected residual detergent fragments, specifically from Triton X-100, sodium deoxycholate and sodium dodecyl sulphate (SDS) in decellularized scaffolds; increased SDS concentrations from 0.1% to 1.0% increased both the intensity of SDS fragments and adverse cell outcomes. We also identified cellular remnants, by detecting phosphate and phosphocholine ions in PAA and CHAPS decellularized scaffolds. The present study demonstrates ToF-SIMS is not only a powerful tool for characterization of biologic scaffold surface molecular functionality, but also enables sensitive assessment of decellularization efficacy. We report here on the use of a highly sensitive analytical technique, time of flight secondary ion mass spectroscopy (ToF-SIMS) to characterize detergent decellularized scaffolds. ToF-SIMS detected cellular remnants and residual detergent fragments; increased intensity of the detergent fragments correlated with adverse cell matrix interactions. This study demonstrates the importance of maintaining a balance between cell removal and detergent disruption of matrix architecture and matrix surface ligand landscape. This study also demonstrates the power of ToF-SIMS for the characterization of decellularized scaffolds and capability for assessment of decellularization efficacy. Future use of biologic scaffolds in clinical tissue reconstruction will benefit from the fundamental results described in this work. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  20. Development of a superconductor magnetic suspension and balance prototype facility for studying the feasibility of applying this technique to large scale aerodynamic testing

    NASA Technical Reports Server (NTRS)

    Zapata, R. N.; Humphris, R. R.; Henderson, K. C.

    1975-01-01

    The basic research and development work towards proving the feasibility of operating an all-superconductor magnetic suspension and balance device for aerodynamic testing is presented. The feasibility of applying a quasi-six-degree-of freedom free support technique to dynamic stability research was studied along with the design concepts and parameters for applying magnetic suspension techniques to large-scale aerodynamic facilities. A prototype aerodynamic test facility was implemented. Relevant aspects of the development of the prototype facility are described in three sections: (1) design characteristics; (2) operational characteristics; and (3) scaling to larger facilities.

  1. Non-contact FBG sensing based steam turbine rotor dynamic balance vibration detection system

    NASA Astrophysics Data System (ADS)

    Li, Tianliang; Tan, Yuegang; Cai, Lin

    2015-10-01

    This paper has proposed a non-contact vibration sensor based on fiber Bragg grating sensing, and applied to detect vibration of steam turbine rotor dynamic balance experimental platform. The principle of the sensor has been introduced, as well as the experimental analysis; performance of non-contact FBG vibration sensor has been analyzed in the experiment; in addition, turbine rotor dynamic vibration detection system based on eddy current displacement sensor and non-contact FBG vibration sensor have built; finally, compared with results of signals under analysis of the time domain and frequency domain. The analysis of experimental data contrast shows that: the vibration signal analysis of non-contact FBG vibration sensor is basically the same as the result of eddy current displacement sensor; it verified that the sensor can be used for non-contact measurement of steam turbine rotor dynamic balance vibration.

  2. Comparison of short-term effects of mobilization with movement and Kinesiotaping on pain, function and balance in patellofemoral pain.

    PubMed

    Demirci, Serdar; Kinikli, Gizem Irem; Callaghan, Michael J; Tunay, Volga Bayrakci

    2017-12-01

    The aim of this study was to compare the short-term effects of Mobilization with movement (MWM) and Kinesiotaping (KT) on patients with patellofemoral pain (PFP) respect to pain, function and balance. Thirty-five female patients diagnosed with unilateral PFP were assigned into 2 groups. The first group (n = 18) received two techniques of MWM intervention (Straight Leg-Raise with Traction and Tibial Gliding) while KT was applied to the other group (n = 17). Both groups received 4 sessions of treatment twice a week for a period of 2 weeks with a 6-week-home exercise program. Pain severity, knee range of motion, hamstring flexibility, and physical performance (10-step stair climbing test, timed up and go test), Kujala Patellofemoral Pain Scoring and Y-Balance test were assessed. These outcomes were evaluated before the treatment, 45 min after the initial treatment, at the end of the 4-session-treatment during 2-week period and 6 weeks later in both groups. Both treatment groups had statistically significant improvements on pain, function and balance (p < 0.05). Pain at rest (p = 0.008) and the hamstring muscle flexibility (p = 0.027) were demonstrated significant improvements in favor of MWM group. Our results demonstrated similar results for both treatment techniques in terms of pain, function and balance. The MWM technique with exercise had a short-term favorable effect on pain at rest and hamstring muscle flexibility than the KT technique with exercise in patients with PFP. Level I, therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  3. Reduction Osteotomy vs Pie-Crust Technique as Possible Alternatives for Medial Release in Total Knee Arthroplasty and Compared in a Prospective Randomized Controlled Trial.

    PubMed

    Ahn, Ji Hyun; Yang, Tae Yeong; Lee, Jang Yun

    2016-07-01

    To compare the gap change between the pie-crust technique and reduction osteotomy to determine their effects on flexion and extension gaps and their success rates in achieving ligament balancing during total knee arthroplasty. In a prospective randomized controlled trial, 106 total knee arthroplasties were allocated to each group with 53 cases. If there was a narrow medial gap with an imbalance of ≥3 mm after the initial limited medial release, either reduction osteotomy or pie-crust technique was performed. The changes of extension and flexion medial gaps along with the success rate of mediolateral balancing were compared. There was a significant difference in the change of medial gap in knee extension with mean changes of 3.5 ± 0.5 mm and 2.3 ± 0.8 mm in the reduction osteotomy and pie-crust groups, respectively (P < .001). For flexion gap, greater change was found in the pie-crust group compared with the reduction osteotomy group; the mean medial gap changes in knee flexion were 1.1 ± 0.5 mm and 2.3 ± 1.2 mm in the reduction osteotomy and pie-crust groups, respectively. The success rates were 90.6% and 67.9% in reduction osteotomy and pie-crust groups, respectively (P = .007). As an alternative medial release method, reduction osteotomy was more effective in extension gap balancing, and pie-crust technique was more effective in flexion gap balancing. The overall success rate of mediolateral ligament balancing was higher in the reduction osteotomy group than in the pie-crust group. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. The Berg Balance Scale has high intra- and inter-rater reliability but absolute reliability varies across the scale: a systematic review.

    PubMed

    Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline

    2013-06-01

    What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Systematic review with meta-analysis of reliability studies. Any clinical population that has undergone assessment with the Berg Balance Scale. Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. Copyright © 2013 Australian Physiotherapy Association. Published by .. All rights reserved.

  5. Reliability and Validity Evidence of Multiple Balance Assessments in Athletes With a Concussion

    PubMed Central

    Murray, Nicholas; Salvatore, Anthony; Powell, Douglas; Reed-Jones, Rebecca

    2014-01-01

    Context: An estimated 300 000 sport-related concussion injuries occur in the United States annually. Approximately 30% of individuals with concussions experience balance disturbances. Common methods of balance assessment include the Clinical Test of Sensory Organization and Balance (CTSIB), the Sensory Organization Test (SOT), the Balance Error Scoring System (BESS), and the Romberg test; however, the National Collegiate Athletic Association recommended the Wii Fit as an alternative measure of balance in athletes with a concussion. A central concern regarding the implementation of the Wii Fit is whether it is reliable and valid for measuring balance disturbance in athletes with concussion. Objective: To examine the reliability and validity evidence for the CTSIB, SOT, BESS, Romberg test, and Wii Fit for detecting balance disturbance in athletes with a concussion. Data Sources: Literature considered for review included publications with reliability and validity data for the assessments of balance (CTSIB, SOT, BESS, Romberg test, and Wii Fit) from PubMed, PsycINFO, and CINAHL. Data Extraction: We identified 63 relevant articles for consideration in the review. Of the 63 articles, 28 were considered appropriate for inclusion and 35 were excluded. Data Synthesis: No current reliability or validity information supports the use of the CTSIB, SOT, Romberg test, or Wii Fit for balance assessment in athletes with a concussion. The BESS demonstrated moderate to high reliability (interclass correlation coefficient = 0.87) and low to moderate validity (sensitivity = 34%, specificity = 87%). However, the Romberg test and Wii Fit have been shown to be reliable tools in the assessment of balance in Parkinson patients. Conclusions: The BESS can evaluate balance problems after a concussion. However, it lacks the ability to detect balance problems after the third day of recovery. Further investigation is needed to establish the use of the CTSIB, SOT, Romberg test, and Wii Fit for assessing balance in athletes with concussions. PMID:24933431

  6. Leak detectability of the Norman Wells pipeline by mass balance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liou, J.C.P.

    Pipeline leak detection using software-based systems is becoming common practice. The detectability of such systems is measured by how small and how quickly a leak can be detected. Algorithms used and measurement uncertainties determine leak detectability. This paper addresses leak detectability using mass balance, establishes leak detectability for Norman Wells pipelines, and compares it with field leak test results. The pipeline is operated by the Interprovincial Pipe Line (IPL) Inc., of Edmonton, Canada. It is a 12.75-inch outside diameter steel pipe with variable wall thickness. The length of the pipe is approximately 550 miles (868.9 km). The pipeline transports lightmore » crude oil at a constant flow rate of about 250 m{sup 3}/hr. The crude oil can enter the pipeline at two locations. Besides the Norman Wells inlet, there is a side line near Zama terminal that can inject crude oil into the pipeline.« less

  7. Nevada National Security Site: Site-Directed Research and Development (SDRD) Fiscal Year 2015 Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bender, Howard A.

    This report presents results of multiple research projects, new and ongoing, funded under the Site-Directed Research and Development Program for the Nevada National Security Site during federal fiscal year 2015. The Site's legacy capabilities in remote sensing combined with new paradigms for emergency response and consequence management help drive the need to develop advanced aerial sensor platforms. Likewise, dynamic materials science is a critical area of scientific research for which basic physics issues are still unresolved. New methods of characterizing materials in extreme states are vitally needed, and these efforts are paving the way with new knowledge. Projects selected inmore » FY 2015 for the Exploratory Research portfolio exhibit a strong balance of NNSS mission relevance. Geoscience, seismology, and techniques for detecting underground nuclear events are still essential focus areas. Many of the project reports in the second major section of this annual report are ongoing continuations in multi-year lifecycles. Diagnostic techniques for stockpile and nuclear security science figured prominently as well, with a few key efforts coming to fruition, such as phase transition detection. In other areas, modeling efforts toward better understanding plasma focus physics has also started to pay dividends for major program needs.« less

  8. Using statistical text classification to identify health information technology incidents

    PubMed Central

    Chai, Kevin E K; Anthony, Stephen; Coiera, Enrico; Magrabi, Farah

    2013-01-01

    Objective To examine the feasibility of using statistical text classification to automatically identify health information technology (HIT) incidents in the USA Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database. Design We used a subset of 570 272 incidents including 1534 HIT incidents reported to MAUDE between 1 January 2008 and 1 July 2010. Text classifiers using regularized logistic regression were evaluated with both ‘balanced’ (50% HIT) and ‘stratified’ (0.297% HIT) datasets for training, validation, and testing. Dataset preparation, feature extraction, feature selection, cross-validation, classification, performance evaluation, and error analysis were performed iteratively to further improve the classifiers. Feature-selection techniques such as removing short words and stop words, stemming, lemmatization, and principal component analysis were examined. Measurements κ statistic, F1 score, precision and recall. Results Classification performance was similar on both the stratified (0.954 F1 score) and balanced (0.995 F1 score) datasets. Stemming was the most effective technique, reducing the feature set size to 79% while maintaining comparable performance. Training with balanced datasets improved recall (0.989) but reduced precision (0.165). Conclusions Statistical text classification appears to be a feasible method for identifying HIT reports within large databases of incidents. Automated identification should enable more HIT problems to be detected, analyzed, and addressed in a timely manner. Semi-supervised learning may be necessary when applying machine learning to big data analysis of patient safety incidents and requires further investigation. PMID:23666777

  9. Assessment of motor balance and coordination in mice using the balance beam.

    PubMed

    Luong, Tinh N; Carlisle, Holly J; Southwell, Amber; Patterson, Paul H

    2011-03-10

    Brain injury, genetic manipulations, and pharmacological treatments can result in alterations of motor skills in mice. Fine motor coordination and balance can be assessed by the beam walking assay. The goal of this test is for the mouse to stay upright and walk across an elevated narrow beam to a safe platform. This test takes place over 3 consecutive days: 2 days of training and 1 day of testing. Performance on the beam is quantified by measuring the time it takes for the mouse to traverse the beam and the number of paw slips that occur in the process. Here we report the protocol used in our laboratory, and representative results from a cohort of C57BL/6 mice. This task is particularly useful for detecting subtle deficits in motor skills and balance that may not be detected by other motor tests, such as the Rotarod.

  10. Assessment of Motor Balance and Coordination in Mice using the Balance Beam

    PubMed Central

    Southwell, Amber; Patterson, Paul H.

    2011-01-01

    Brain injury, genetic manipulations, and pharmacological treatments can result in alterations of motor skills in mice. Fine motor coordination and balance can be assessed by the beam walking assay. The goal of this test is for the mouse to stay upright and walk across an elevated narrow beam to a safe platform. This test takes place over 3 consecutive days: 2 days of training and 1 day of testing. Performance on the beam is quantified by measuring the time it takes for the mouse to traverse the beam and the number of paw slips that occur in the process. Here we report the protocol used in our laboratory, and representative results from a cohort of C57BL/6 mice. This task is particularly useful for detecting subtle deficits in motor skills and balance that may not be detected by other motor tests, such as the Rotarod. PMID:21445033

  11. Development of a quantitative in-shoe measurement system for assessing balance: sixteen-sensor insoles.

    PubMed

    Bamberg, Stacy M; Lastayo, Paul; Dibble, Lee; Musselman, Josh; Raghavendra, Swarna Kiran Dasa

    2006-01-01

    This work presents the first phase in the development of an in-shoe sensor system designed to evaluate balance. Sixteen force-sensitive resistors were strategically mounted to a removable insole, and the bilateral outputs were recorded. The initial results indicate that these sensors are capable of detecting subtle changes in weight distribution, corresponding to the subject's ability to balance. Preliminary analysis of this data found a clear correlation between the ability to balance and the state of health of the subject.

  12. Adaptive Load-Balancing Algorithms Using Symmetric Broadcast Networks

    NASA Technical Reports Server (NTRS)

    Das, Sajal K.; Biswas, Rupak; Chancellor, Marisa K. (Technical Monitor)

    1997-01-01

    In a distributed-computing environment, it is important to ensure that the processor workloads are adequately balanced. Among numerous load-balancing algorithms, a unique approach due to Dam and Prasad defines a symmetric broadcast network (SBN) that provides a robust communication pattern among the processors in a topology-independent manner. In this paper, we propose and analyze three novel SBN-based load-balancing algorithms, and implement them on an SP2. A thorough experimental study with Poisson-distributed synthetic loads demonstrates that these algorithms are very effective in balancing system load while minimizing processor idle time. They also compare favorably with several other existing load-balancing techniques. Additional experiments performed with real data demonstrate that the SBN approach is effective in adaptive computational science and engineering applications where dynamic load balancing is extremely crucial.

  13. Even-order harmonic cancellation for off-quadrature biased Mach-Zehnder modulator with improved RF metrics using dual wavelength inputs and dual outputs.

    PubMed

    Devgan, Preetpaul S; Diehl, John F; Urick, Vincent J; Sunderman, Christopher E; Williams, Keith J

    2009-05-25

    We present a technique using a dual-output Mach-Zehnder modulator (MZM) with two wavelength inputs, one operating at low-bias and the other operating at high-bias, in order to cancel unwanted even-order harmonics in analog optical links. By using a dual-output MZM, this technique allows for two suppressed optical carriers to be transmitted to the receiver. Combined with optical amplification and balanced differential detection, the RF power of the fundamental is increased by 2 dB while the even-order harmonic is reduced by 47 dB, simultaneously. The RF noise figure and third-order spurious-free dynamic range (SFDR(3)) are improved by 5.4 dB and 3.6 dB, respectively. Using a wavelength sensitive, low V(pi) MZM allows the two wavelengths to be within 5.5 nm of each other for a frequency band from 10 MHz to 100 MHz and 10 nm for 1 GHz.

  14. [Arterial hypertension in children].

    PubMed

    Mota-Hernández, F

    1993-07-01

    It is considered hypertension in children, the persistent increase of the blood pressure values above percentile 95 for age and sex, in no less than three determinations, with adequate register techniques. Blood pressure is maintained mainly by the regulation of metabolism of sodium and water in the intravascular space, through the adequate balance of intake, filtration, reabsorption and renal throughout. It is also regulated by hormonal factors. Weight gain control in teen-agers could be useful to prevent high blood pressure in adults. In children, it is generally secondary to renal, reno-vascular, endocrinological or tumoral diseases. Clinical manifestations and the recommended diagnostic procedures are analysed to detect the most frequent causes of hypertension at different ages. Most cases response with antihypertensive drugs in combination with hyposodic diet. For the hypertensive crisis, asa diuretics and powerful antihypertensive drugs may be employed. Patients with chronic renal insufficiency could also need dialytic treatments. Renovascular diseases require almost always invasive treatments. Better prognosis in children with severe high blood pressure is related with recent diagnostic procedures, surgical techniques and antihypertensive drugs improvements.

  15. On the Structural Plasticity of the Human Genome: Chromosomal Inversions Revisited

    PubMed Central

    Alves, Joao M; Lopes, Alexandra M; Chikhi, Lounès; Amorim, António

    2012-01-01

    With the aid of novel and powerful molecular biology techniques, recent years have witnessed a dramatic increase in the number of studies reporting the involvement of complex structural variants in several genomic disorders. In fact, with the discovery of Copy Number Variants (CNVs) and other forms of unbalanced structural variation, much attention has been directed to the detection and characterization of such rearrangements, as well as the identification of the mechanisms involved in their formation. However, it has long been appreciated that chromosomes can undergo other forms of structural changes - balanced rearrangements - that do not involve quantitative variation of genetic material. Indeed, a particular subtype of balanced rearrangement – inversions – was recently found to be far more common than had been predicted from traditional cytogenetics. Chromosomal inversions alter the orientation of a specific genomic sequence and, unless involving breaks in coding or regulatory regions (and, disregarding complex trans effects, in their close vicinity), appear to be phenotypically silent. Such a surprising finding, which is difficult to reconcile with the classical interpretation of inversions as a mechanism causing subfertility (and ultimately reproductive isolation), motivated a new series of theoretical and empirical studies dedicated to understand their role in human genome evolution and to explore their possible association to complex genetic disorders. With this review, we attempt to describe the latest methodological improvements to inversions detection at a genome wide level, while exploring some of the possible implications of inversion rearrangements on the evolution of the human genome. PMID:23730202

  16. Balanced Steady-State Free Precession (bSSFP) from an effective field perspective: Application to the detection of chemical exchange (bSSFPX).

    PubMed

    Zhang, Shu; Liu, Zheng; Grant, Aaron; Keupp, Jochen; Lenkinski, Robert E; Vinogradov, Elena

    2017-02-01

    Chemical exchange saturation transfer (CEST) is a novel contrast mechanism and it is gaining increasing popularity as many promising applications have been proposed and investigated. Fast and quantitative CEST imaging techniques are further needed in order to increase the applicability of CEST for clinical use as well as to derive quantitative physiological and biological information. Steady-state methods for fast CEST imaging have been reported recently. Here, we observe that an extreme case of these methods is a balanced steady-state free precession (bSSFP) sequence. The bSSFP in itself is sensitive to the exchange processes; hence, no additional saturation or preparation is needed for CEST-like data acquisition. The bSSFP experiment can be regarded as observation during saturation, without separate saturation and acquisition modules as used in standard CEST and similar experiments. One of the differences from standard CEST methods is that the bSSFP spectrum is an XY-spectrum not a Z-spectrum. As the first proof-of-principle step, we have implemented the steady-state bSSFP sequence for chemical exchange detection (bSSFPX) and verified its feasibility in phantom studies. These studies have shown that bSSFPX can achieve exchange-mediated contrast comparable to the standard CEST experiment. Therefore, the bSSFPX method has a potential for fast and quantitative CEST data acquisition. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Model Reduction for Control System Design

    NASA Technical Reports Server (NTRS)

    Enns, D. F.

    1985-01-01

    An approach and a technique for effectively obtaining reduced order mathematical models of a given large order model for the purposes of synthesis, analysis and implementation of control systems is developed. This approach involves the use of an error criterion which is the H-infinity norm of a frequency weighted error between the full and reduced order models. The weightings are chosen to take into account the purpose for which the reduced order model is intended. A previously unknown error bound in the H-infinity norm for reduced order models obtained from internally balanced realizations was obtained. This motivated further development of the balancing technique to include the frequency dependent weightings. This resulted in the frequency weighted balanced realization and a new model reduction technique. Two approaches to designing reduced order controllers were developed. The first involves reducing the order of a high order controller with an appropriate weighting. The second involves linear quadratic Gaussian synthesis based on a reduced order model obtained with an appropriate weighting.

  18. Reduced-order modeling for hyperthermia: an extended balanced-realization-based approach.

    PubMed

    Mattingly, M; Bailey, E A; Dutton, A W; Roemer, R B; Devasia, S

    1998-09-01

    Accurate thermal models are needed in hyperthermia cancer treatments for such tasks as actuator and sensor placement design, parameter estimation, and feedback temperature control. The complexity of the human body produces full-order models which are too large for effective execution of these tasks, making use of reduced-order models necessary. However, standard balanced-realization (SBR)-based model reduction techniques require a priori knowledge of the particular placement of actuators and sensors for model reduction. Since placement design is intractable (computationally) on the full-order models, SBR techniques must use ad hoc placements. To alleviate this problem, an extended balanced-realization (EBR)-based model-order reduction approach is presented. The new technique allows model order reduction to be performed over all possible placement designs and does not require ad hoc placement designs. It is shown that models obtained using the EBR method are more robust to intratreatment changes in the placement of the applied power field than those models obtained using the SBR method.

  19. Supertitrations: High-Precision Methods.

    ERIC Educational Resources Information Center

    Guenther, W. B.

    1988-01-01

    Offers challenging work at a higher level of technique than most students meet in elementary laboratory work. Uses a combined weight and volumetric sequence not shown in textbooks. Notes modern rapid balances help lower evaporation loss during weighings. Discusses the balance, weights, and buoyancy considerations. (MVL)

  20. Mental imagery. Effects on static balance and attentional demands of the elderly.

    PubMed

    Hamel, M F; Lajoie, Yves

    2005-06-01

    Several studies have demonstrated the effectiveness of mental imagery in improving motor performance. However, no research has studied the effectiveness of such a technique on static balance in the elderly. This study evaluated the efficiency of a mental imagery technique, aimed at improving static balance by reducing postural oscillations and attentional demands in the elderly. Twenty subjects aged 65 to 90 years old, divided into two groups (8 in Control group and 12 in Experimental group) participated in the study. The experimental participants underwent daily mental imagery training for a period of six weeks. Antero-posterior and lateral oscillations, reaction times during the use of the double-task paradigm were measured, and the Berg Balance Scale, Activities-specific Balance Confidence Scale, and VMIQ questionnaire were answered during both pre-test and post-test. Attentional demands and postural oscillations (antero-posterior) decreased significantly in the group with mental imagery training compared with those of the Control group. Subjects in the mental imagery group became significantly better in their aptitudes to generate clear vivid mental images, as indicated by the VMIQ questionnaire, whereas no significant difference was observed for the Activities-specific Balance Confidence Scale or Berg Scale. The results support psychoneuromuscular and motor coding theories associated with mental imagery.

  1. Efficacy and Safety of a Novel Three-Step Medial Release Technique in Varus Total Knee Arthroplasty.

    PubMed

    Kim, Min Woo; Koh, In Jun; Kim, Ju Hwan; Jung, Jae Jong; In, Yong

    2015-09-01

    We investigated the efficacy and safety of our novel three-step medial release technique in varus total knee arthroplasty (TKA) over time. Two hundred sixty seven consecutive varus TKAs were performed by applying the algorithmic release technique which consisted of sequential release of the deep medial collateral ligament (step 1), the semimembranosus (step 2), and multiple needle puncturing of the superficial medial collateral ligament (step 3). One hundred seventeen, 114, and 36 knees were balanced after step 1, 2, and 3 releases, respectively. There were no significant differences in changes of medial and lateral laxities between groups in over a year. Our novel stepwise medial release technique was efficacious and safe in balancing varus knees during TKA. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Measured and perceived indices of fluid balance in professional athletes. The use and impact of hydration assessment strategies.

    PubMed

    Love, T D; Baker, D F; Healey, P; Black, K E

    2018-04-01

    To determine athletes perceived and measured indices of fluid balance during training and the influence of hydration strategy use on these parameters. Thirty-three professional rugby union players completed a 120 minute training session in hot conditions (35°C, 40% relative humidity). Pre-training hydration status, sweat loss, fluid intake and changes in body mass (BM) were obtained. The use of hydration assessment techniques and players perceptions of fluid intake and sweat loss were obtained via a questionnaire. The majority of players (78%) used urine colour to determine pre-training hydration status but the use of hydration assessment techniques did not influence pre-training hydration status (1.025 ± 0.005 vs. 1.023 ± 0.013 g . ml -1 , P = .811). Players underestimated sweat loss (73 ± 17%) to a greater extent than fluid intake (37 ± 28%) which resulted in players perceiving they were in positive fluid balance (0.5 ± 0.8% BM) rather than the measured negative fluid balance (-1.0 ± 0.7% BM). Forty-eight percent of players used hydration monitoring strategies during exercise but no player used changes in BM to help guide fluid replacement. Players have difficulty perceiving fluid intake and sweat loss during training. However, the use of hydration monitoring techniques did not affect fluid balance before or during training.

  3. [Hepatic resections].

    PubMed

    Mercado, M A; Paquet, K J

    1990-07-01

    Liver resection are now accepted as a part of the surgical therapeutic armamentarium. In this review the anatomical and technical aspects, as well as the main indications, are discussed. The new image technique have largely contributed to the early detection of lesions that can be resected. The main indication for these procedures are malignant lesions (primary or metastatic) as well as symptomatic benign lesions. The importance to study, diagnose and treat benign lesions are justified by the possibility to detect and resect a potentially curable malignant disease. Major liver resections are contraindicated in patients with liver cirrhosis, because of a high morbimortality. Operative mortality for major liver resection is about 10% in most centers and the survival of patients with malignant disease treated by this modality is better than that of the patients treated with conservative measures. All patients with space-occupying lesions of the liver deserve the benefit of the doubt to be considered for surgical treatment. The individual features of each patient, with a judicious balance between risk and benefit, indicate or contraindicate these procedures.

  4. Ultrasensitive dual-beam absorption and gain spectroscopy: applications for near-infrared and visible diode laser sensors

    NASA Astrophysics Data System (ADS)

    Allen, Mark G.; Carleton, Karen L.; Davis, Steven J.; Kessler, William J.; Otis, Charles E.; Palombo, Daniel A.; Sonnenfroh, David M.

    1995-06-01

    A dual-beam detection strategy with automatic balancing is described for ultrasensitive spectroscopy. Absorbances of 2 \\times 10-7 Hz-1/2 in free-space configurations and 5 \\times 10-6 Hz -1/2 in fiber-coupled configurations are demonstrated. With the dual-beam technique, atmospherically broadened absorption transitions may be resolved with InGaAsP, AlGaAs, and AlGaInP single-longitudinal-mode diode lasers. Applications to trace measurements of NO2 , O2, and H2O are described by the use of simple, inexpensive laser and detector systems. Small signal gain measurements on optically pumped I2 with a sensitivity of 10-5 are also reported.

  5. Vestibular signals in primate cortex for self-motion perception.

    PubMed

    Gu, Yong

    2018-04-21

    The vestibular peripheral organs in our inner ears detect transient motion of the head in everyday life. This information is sent to the central nervous system for automatic processes such as vestibulo-ocular reflexes, balance and postural control, and higher cognitive functions including perception of self-motion and spatial orientation. Recent neurophysiological studies have discovered a prominent vestibular network in the primate cerebral cortex. Many of the areas involved are multisensory: their neurons are modulated by both vestibular signals and visual optic flow, potentially facilitating more robust heading estimation through cue integration. Combining psychophysics, computation, physiological recording and causal manipulation techniques, recent work has addressed both the encoding and decoding of vestibular signals for self-motion perception. Copyright © 2018. Published by Elsevier Ltd.

  6. Elimination of residual amplitude modulation in tunable diode laser wavelength modulation spectroscopy using an optical fiber delay line.

    PubMed

    Chakraborty, Arup Lal; Ruxton, Keith; Johnstone, Walter; Lengden, Michael; Duffin, Kevin

    2009-06-08

    A new fiber-optic technique to eliminate residual amplitude modulation in tunable diode laser wavelength modulation spectroscopy is presented. The modulated laser output is split to pass in parallel through the gas measurement cell and an optical fiber delay line, with the modulation frequency / delay chosen to introduce a relative phase shift of pi between them. The two signals are balanced using a variable attenuator and recombined through a fiber coupler. In the absence of gas, the direct laser intensity modulation cancels, thereby eliminating the high background. The presence of gas induces a concentration-dependent imbalance at the coupler's output from which the absolute absorption profile is directly recovered with high accuracy using 1f detection.

  7. Load balance in total knee arthroplasty: an in vitro analysis.

    PubMed

    El-Hawary, Ron; Roth, Sandra E; King, Graham J W; Chess, David G; Johnson, James A

    2006-09-01

    One of the goals of total knee arthroplasty (TKA) is to balance the loads between the compartments of the knee. An instrumented load cell that measures compartment loads in real time is utilized to evaluate conventional, qualitative methods of achieving this balance. TKA was performed on 10 cadaveric knees. Prior to and after load balancing, compartment forces were measured at flexion angles of 0-90 degrees. Knees were randomly assigned into one of two groups, based upon whether or not the surgeons could visualize the load cell's output during balancing. Prior to attempting load balance, there were significant differences between the medial and lateral compartment loads for all knees (p < 0.05). After attempting balance with the aid of the load cell, there was equal load balance at all angles studied. Without the aid of the load cell, balance was not consistently achieved at every angle. Conventional load balancing techniques in TKA are not perfect. Copyright 2006 John Wiley & Sons, Ltd.

  8. Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

    NASA Technical Reports Server (NTRS)

    Bloomberg, Jacob; Reschke, Millard; Mulavara, Ajitkumar; Wood, Scott; Serrador, Jorge; Fiedler, Matthew; Kofman, Igor; Peters, Brian T.; Cohen, Helen

    2012-01-01

    Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain's ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable and provides imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles. SR using imperceptible stochastic electrical stimulation of the vestibular system (stochastic vestibular stimulation, SVS) applied to normal subjects has shown to improve the degree of association between the weak input periodic signals introduced via venous blood pressure receptors and the heart-rate responses. Also, application of SVS over 24 hours improves the long-term heart-rate dynamics and motor responsiveness as indicated by daytime trunk activity measurements in patients with multi-system atrophy, Parkinson s disease, or both, including patients who were unresponsive to standard therapy for Parkinson s disease. Recent studies conducted at the NASA JSC Neurosciences Laboratories showed that imperceptible SVS, when applied to normal young healthy subjects, leads to significantly improved balance performance during postural disturbances on unstable compliant surfaces. These studies have shown the benefit of SR noise characteristic optimization with imperceptible SVS in the frequency range of 0-30 Hz, and amplitudes of stimulation have ranged from 100 to 400 microamperes.

  9. Identification of the period of stability in a balance test after stepping up using a simplified cumulative sum.

    PubMed

    Safieddine, Doha; Chkeir, Aly; Herlem, Cyrille; Bera, Delphine; Collart, Michèle; Novella, Jean-Luc; Dramé, Moustapha; Hewson, David J; Duchêne, Jacques

    2017-11-01

    Falls are a major cause of death in older people. One method used to predict falls is analysis of Centre of Pressure (CoP) displacement, which provides a measure of balance quality. The Balance Quality Tester (BQT) is a device based on a commercial bathroom scale that calculates instantaneous values of vertical ground reaction force (Fz) as well as the CoP in both anteroposterior (AP) and mediolateral (ML) directions. The entire testing process needs to take no longer than 12 s to ensure subject compliance, making it vital that calculations related to balance are only calculated for the period when the subject is static. In the present study, a method is presented to detect the stabilization period after a subject has stepped onto the BQT. Four different phases of the test are identified (stepping-on, stabilization, balancing, stepping-off), ensuring that subjects are static when parameters from the balancing phase are calculated. The method, based on a simplified cumulative sum (CUSUM) algorithm, could detect the change between unstable and stable stance. The time taken to stabilize significantly affected the static balance variables of surface area and trajectory velocity, and was also related to Timed-up-and-Go performance. Such a finding suggests that the time to stabilize could be a worthwhile parameter to explore as a potential indicator of balance problems and fall risk in older people. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Beam walking can detect differences in walking balance proficiency across a range of sensorimotor abilities.

    PubMed

    Sawers, Andrew; Ting, Lena H

    2015-02-01

    The ability to quantify differences in walking balance proficiency is critical to curbing the rising health and financial costs of falls. Current laboratory-based approaches typically focus on successful recovery of balance while clinical instruments often pose little difficulty for all but the most impaired patients. Rarely do they test motor behaviors of sufficient difficulty to evoke failures in balance control limiting their ability to quantify balance proficiency. Our objective was to test whether a simple beam-walking task could quantify differences in walking balance proficiency across a range of sensorimotor abilities. Ten experts, ten novices, and five individuals with transtibial limb loss performed six walking trials across three different width beams. Walking balance proficiency was quantified as the ratio of distance walked to total possible distance. Balance proficiency was not significantly different between cohorts on the wide-beam, but clear differences between cohorts on the mid and narrow-beams were identified. Experts walked a greater distance than novices on the mid-beam (average of 3.63±0.04m verus 2.70±0.21m out of 3.66m; p=0.009), and novices walked further than amputees (1.52±0.20m; p=0.03). Amputees were unable to walk on the narrow-beam, while experts walked further (3.07±0.14m) than novices (1.55±0.26m; p=0.0005). A simple beam-walking task and an easily collected measure of distance traveled detected differences in walking balance proficiency across sensorimotor abilities. This approach provides a means to safely study and evaluate successes and failures in walking balance in the clinic or lab. It may prove useful in identifying mechanisms underlying falls versus fall recoveries. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Load Balancing Using Time Series Analysis for Soft Real Time Systems with Statistically Periodic Loads

    NASA Technical Reports Server (NTRS)

    Hailperin, Max

    1993-01-01

    This thesis provides design and analysis of techniques for global load balancing on ensemble architectures running soft-real-time object-oriented applications with statistically periodic loads. It focuses on estimating the instantaneous average load over all the processing elements. The major contribution is the use of explicit stochastic process models for both the loading and the averaging itself. These models are exploited via statistical time-series analysis and Bayesian inference to provide improved average load estimates, and thus to facilitate global load balancing. This thesis explains the distributed algorithms used and provides some optimality results. It also describes the algorithms' implementation and gives performance results from simulation. These results show that our techniques allow more accurate estimation of the global system load ing, resulting in fewer object migration than local methods. Our method is shown to provide superior performance, relative not only to static load-balancing schemes but also to many adaptive methods.

  12. Identification of balanced chromosomal rearrangements previously unknown among participants in the 1000 Genomes Project: implications for interpretation of structural variation in genomes and the future of clinical cytogenetics.

    PubMed

    Dong, Zirui; Wang, Huilin; Chen, Haixiao; Jiang, Hui; Yuan, Jianying; Yang, Zhenjun; Wang, Wen-Jing; Xu, Fengping; Guo, Xiaosen; Cao, Ye; Zhu, Zhenzhen; Geng, Chunyu; Cheung, Wan Chee; Kwok, Yvonne K; Yang, Huanming; Leung, Tak Yeung; Morton, Cynthia C; Cheung, Sau Wai; Choy, Kwong Wai

    2017-11-02

    PurposeRecent studies demonstrate that whole-genome sequencing enables detection of cryptic rearrangements in apparently balanced chromosomal rearrangements (also known as balanced chromosomal abnormalities, BCAs) previously identified by conventional cytogenetic methods. We aimed to assess our analytical tool for detecting BCAs in the 1000 Genomes Project without knowing which bands were affected.MethodsThe 1000 Genomes Project provides an unprecedented integrated map of structural variants in phenotypically normal subjects, but there is no information on potential inclusion of subjects with apparent BCAs akin to those traditionally detected in diagnostic cytogenetics laboratories. We applied our analytical tool to 1,166 genomes from the 1000 Genomes Project with sufficient physical coverage (8.25-fold).ResultsWith this approach, we detected four reciprocal balanced translocations and four inversions, ranging in size from 57.9 kb to 13.3 Mb, all of which were confirmed by cytogenetic methods and polymerase chain reaction studies. One of these DNAs has a subtle translocation that is not readily identified by chromosome analysis because of the similarity of the banding patterns and size of exchanged segments, and another results in disruption of all transcripts of an OMIM gene.ConclusionOur study demonstrates the extension of utilizing low-pass whole-genome sequencing for unbiased detection of BCAs including translocations and inversions previously unknown in the 1000 Genomes Project.GENETICS in MEDICINE advance online publication, 2 November 2017; doi:10.1038/gim.2017.170.

  13. Analysis of biochemical phase shift oscillators by a harmonic balancing technique.

    PubMed

    Rapp, P

    1976-11-25

    The use of harmonic balancing techniques for theoretically investigating a large class of biochemical phase shift oscillators is outlined and the accuracy of this approximate technique for large dimension nonlinear chemical systems is considered. It is concluded that for the equations under study these techniques can be successfully employed to both find periodic solutions and to indicate those cases which can not oscillate. The technique is a general one and it is possible to state a step by step procedure for its application. It has a substantial advantage in producing results which are immediately valid for arbitrary dimension. As the accuracy of the method increases with dimension, it complements classical small dimension methods. The results obtained by harmonic balancing analysis are compared with those obtained by studying the local stability properties of the singular points of the differential equation. A general theorem is derived which identifies those special cases where the results of first order harmonic balancing are identical to those of local stability analysis, and a necessary condition for this equivalence is derived. As a concrete example, the n-dimensional Goodwin oscillator is considered where p, the Hill coefficient of the feedback metabolite, is equal to three and four. It is shown that for p = 3 or 4 and n less than or equal to 4 the approximation indicates that it is impossible to construct a set of physically permissible reaction constants such that the system possesses a periodic solution. However for n greater than or equal to 5 it is always possible to find a large domain in the reaction constant space giving stable oscillations. A means of constructing such a parameter set is given. The results obtained here are compared with previously derived results for p = 1 and p = 2.

  14. A drag measurement technique for free piston shock tunnels

    NASA Technical Reports Server (NTRS)

    Sanderson, S. R.; Simmons, J. M.; Tuttle, S. L.

    1991-01-01

    A new technique is described for measuring drag with 100-microsecond rise time on a nonlifting model in a free piston shock tunnel. The technique involves interpretation of the stress waves propagating within the model and its support. A finite element representation and spectral methods are used to obtain a mean square optimal estimate of the time history of the aerodynamic loading. Thus, drag is measured instantaneously and the previous restriction caused by the mechanical time constant of balances is overcome. The effectiveness of the balance is demonstrated by measuring the drag on cones with 5 and 15 deg semi-vertex angles in nominally Mach 5.6 flow with stagnation enthalpies from 2.6 to 33 MJ/kg.

  15. Is the difference between chemical and numerical estimates of baseflow meaningful?

    NASA Astrophysics Data System (ADS)

    Cartwright, Ian; Gilfedder, Ben; Hofmann, Harald

    2014-05-01

    Both chemical and numerical techniques are commonly used to calculate baseflow inputs to gaining rivers. In general the chemical methods yield lower estimates of baseflow than the numerical techniques. In part, this may be due to the techniques assuming two components (event water and baseflow) whereas there may also be multiple transient stores of water. Bank return waters, interflow, or waters stored on floodplains are delayed components that may be geochemically similar to the surface water from which they are derived; numerical techniques may record these components as baseflow whereas chemical mass balance studies are likely to aggregate them with the surface water component. This study compares baseflow estimates using chemical mass balance, local minimum methods, and recursive digital filters in the upper reaches of the Barwon River, southeast Australia. While more sophisticated techniques exist, these methods of estimating baseflow are readily applied with the available data and have been used widely elsewhere. During the early stages of high-discharge events, chemical mass balance overestimates groundwater inflows, probably due to flushing of saline water from wetlands and marshes, soils, or the unsaturated zone. Overall, however, estimates of baseflow from the local minimum and recursive digital filters are higher than those from chemical mass balance using Cl calculated from continuous electrical conductivity. Between 2001 and 2011, the baseflow contribution to the upper Barwon River calculated using chemical mass balance is between 12 and 25% of annual discharge. Recursive digital filters predict higher baseflow contributions of 19 to 52% of annual discharge. These estimates are similar to those from the local minimum method (16 to 45% of annual discharge). These differences most probably reflect how the different techniques characterise the transient water sources in this catchment. The local minimum and recursive digital filters aggregate much of the water from delayed sources as baseflow. However, as many of these delayed transient water stores (such as bank return flow, floodplain storage, or interflow) have Cl concentrations that are similar to surface runoff, chemical mass balance calculations aggregate them with the surface runoff component. The difference between the estimates is greatest following periods of high discharge in winter, implying that these transient stores of water feed the river for several weeks to months at that time. Cl vs. discharge variations during individual flow events also demonstrate that inflows of high-salinity older water occurs on the rising limbs of hydrographs followed by inflows of low-salinity water from the transient stores as discharge falls. The use of complementary techniques allows a better understanding of the different components of water that contribute to river flow, which is important for the management and protection of water resources.

  16. The Comparison of Matching Methods Using Different Measures of Balance: Benefits and Risks Exemplified within a Study to Evaluate the Effects of German Disease Management Programs on Long-Term Outcomes of Patients with Type 2 Diabetes.

    PubMed

    Fullerton, Birgit; Pöhlmann, Boris; Krohn, Robert; Adams, John L; Gerlach, Ferdinand M; Erler, Antje

    2016-10-01

    To present a case study on how to compare various matching methods applying different measures of balance and to point out some pitfalls involved in relying on such measures. Administrative claims data from a German statutory health insurance fund covering the years 2004-2008. We applied three different covariance balance diagnostics to a choice of 12 different matching methods used to evaluate the effectiveness of the German disease management program for type 2 diabetes (DMPDM2). We further compared the effect estimates resulting from applying these different matching techniques in the evaluation of the DMPDM2. The choice of balance measure leads to different results on the performance of the applied matching methods. Exact matching methods performed well across all measures of balance, but resulted in the exclusion of many observations, leading to a change of the baseline characteristics of the study sample and also the effect estimate of the DMPDM2. All PS-based methods showed similar effect estimates. Applying a higher matching ratio and using a larger variable set generally resulted in better balance. Using a generalized boosted instead of a logistic regression model showed slightly better performance for balance diagnostics taking into account imbalances at higher moments. Best practice should include the application of several matching methods and thorough balance diagnostics. Applying matching techniques can provide a useful preprocessing step to reveal areas of the data that lack common support. The use of different balance diagnostics can be helpful for the interpretation of different effect estimates found with different matching methods. © Health Research and Educational Trust.

  17. Ultrasonic detection of solid phase mass flow ratio of pneumatic conveying fly ash

    NASA Astrophysics Data System (ADS)

    Duan, Guang Bin; Pan, Hong Li; Wang, Yong; Liu, Zong Ming

    2014-04-01

    In this paper, ultrasonic attenuation detection and weight balance are adopted to evaluate the solid mass ratio in this paper. Fly ash is transported on the up extraction fluidization pneumatic conveying workbench. In the ultrasonic test. McClements model and Bouguer-Lambert-Beer law model were applied to formulate the ultrasonic attenuation properties of gas-solid flow, which can give the solid mass ratio. While in the method of weigh balance, the averaged mass addition per second can reveal the solids mass flow ratio. By contrast these two solid phase mass ratio detection methods, we can know, the relative error is less.

  18. Techniques For Focusing In Zone Electrophoresis

    NASA Technical Reports Server (NTRS)

    Sharnez, Rizwan; Twitty, Garland E.; Sammons, David W.

    1994-01-01

    In two techniques for focusing in zone electrophoresis, force of applied electrical field in each charged particle balanced by restoring force of electro-osmosis. Two techniques: velocity-gradient focusing (VGF), suitable for rectangular electrophoresis chambers; and field-gradient focusing (FGF), suitable for step-shaped electrophoresis chambers.

  19. Parallel implementation and evaluation of motion estimation system algorithms on a distributed memory multiprocessor using knowledge based mappings

    NASA Technical Reports Server (NTRS)

    Choudhary, Alok Nidhi; Leung, Mun K.; Huang, Thomas S.; Patel, Janak H.

    1989-01-01

    Several techniques to perform static and dynamic load balancing techniques for vision systems are presented. These techniques are novel in the sense that they capture the computational requirements of a task by examining the data when it is produced. Furthermore, they can be applied to many vision systems because many algorithms in different systems are either the same, or have similar computational characteristics. These techniques are evaluated by applying them on a parallel implementation of the algorithms in a motion estimation system on a hypercube multiprocessor system. The motion estimation system consists of the following steps: (1) extraction of features; (2) stereo match of images in one time instant; (3) time match of images from different time instants; (4) stereo match to compute final unambiguous points; and (5) computation of motion parameters. It is shown that the performance gains when these data decomposition and load balancing techniques are used are significant and the overhead of using these techniques is minimal.

  20. The energy balance within a bubble column evaporator

    NASA Astrophysics Data System (ADS)

    Fan, Chao; Shahid, Muhammad; Pashley, Richard M.

    2018-05-01

    Bubble column evaporator (BCE) systems have been studied and developed for many applications, such as thermal desalination, sterilization, evaporative cooling and controlled precipitation. The heat supplied from warm/hot dry bubbles is to vaporize the water in various salt solutions until the solution temperature reaches steady state, which was derived into the energy balance of the BCE. The energy balance and utilization involved in each BCE process form the fundamental theory of these applications. More importantly, it opened a new field for the thermodynamics study in the form of heat and vapor transfer in the bubbles. In this paper, the originally derived energy balance was reviewed on the basis of its physics in the BCE process and compared with new proposed energy balance equations in terms of obtained the enthalpy of vaporization (Δ H vap) values of salt solutions from BCE experiments. Based on the analysis of derivation and Δ H vap values comparison, it is demonstrated that the original balance equation has high accuracy and precision, within 2% over 19-55 °C using improved systems. Also, the experimental and theoretical techniques used for determining Δ H vap values of salt solutions were reviewed for the operation conditions and their accuracies compared to the literature data. The BCE method, as one of the most simple and accurate techniques, offers a novel way to determine Δ H vap values of salt solutions based on its energy balance equation, which had error less than 3%. The thermal energy required to heat the inlet gas, the energy used for water evaporation in the BCE and the energy conserved from water vapor condensation were estimated in an overall energy balance analysis. The good agreement observed between input and potential vapor condensation energy illustrates the efficiency of the BCE system. Typical energy consumption levels for thermal desalination for producing pure water using the BCE process was also analyzed for different inlet air temperatures, and indicated the better energy efficiency, of 7.55 kW·h per m3 of pure water, compared to traditional thermal desalination techniques.

  1. Gap-Balancing versus Measured Resection Technique in Total Knee Arthroplasty: A Comparison Study.

    PubMed

    Churchill, Jessica L; Khlopas, Anton; Sultan, Assem A; Harwin, Steven F; Mont, Michael A

    2018-01-01

    Proper femoral component alignment in the axial plane during total knee arthroplasty (TKA) depends on accurate bone cuts and soft tissue balancing. Two methods that are used to achieve this are "measured resection" and "gap balancing." However, a controversy exists as to which method is more accurate and leads to better outcomes. Therefore, the purpose of this study was to evaluate: (1) implant survivorship, (2) patient outcomes, (3) complications, and (4) radiographic analysis comparing patients who underwent TKA with either gap-balancing or measured resection techniques. A total of 214 consecutive patients (221 knees) underwent primary TKA by a single surgeon between 2011 and 2012. Component alignment was achieved by using measured resection in 116 knees and gap balancing was used in 105 knees. The patients had a mean age of 66 years (range, 44-86 years) and a mean body mass index of 32 kg/m 2 (range, 22-52 kg/m 2 ). Patient range-of-motion (ROM) and Knee Society (KS) function and pain scores, and radiographic assessment, were assessed preoperatively and postoperatively at ∼6 weeks, 3 months, 1 year, and then annually. The mean follow-up time was 3 years. A Kaplan-Meier's analysis was performed to calculate the survivorship. The aseptic survivorship was 98% in both the measured resection and gap-balancing groups. The mean ROM was not significantly different between the measured resection and gap-balancing groups (123 vs. 123 degrees, p  = 0.990). There were no significant differences between the two groups in terms of the KS function scores (86 vs. 85 points, p  = 0.829) or the KS pain scores (93 vs. 92 points, p  = 0.425). Otherwise, the radiographic evaluation at latest follow-up did not demonstrate any evidence of progressive radiolucencies or loosening, of any prosthesis. The results of this study found that at a mean follow-up of 3 years, both the measured resection and gap-balancing techniques achieved excellent survivorship and postoperative outcomes. This demonstrates that both methods can be used to achieve accurate femoral component alignment with similar short-term outcomes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Bayer Digester Optimization Studies using Computer Techniques

    NASA Astrophysics Data System (ADS)

    Kotte, Jan J.; Schleider, Victor H.

    Theoretically required heat transfer performance by the multistaged flash heat reclaim system of a high pressure Bayer digester unit is determined for various conditions of discharge temperature, excess flash vapor and indirect steam addition. Solution of simultaneous heat balances around the digester vessels and the heat reclaim system yields the magnitude of available heat for representation of each case on a temperature-enthalpy diagram, where graphical fit of the number of flash stages fixes the heater requirements. Both the heat balances and the trial-and-error graphical solution are adapted to solution by digital computer techniques.

  3. Optical heterodyne accelerometry: passively stabilized, fully balanced velocity interferometer system for any reflector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buttler, William T.; Lamoreaux, Steven K.

    2010-08-10

    We formalize the physics of an optical heterodyne accelerometer that allows measurement of low and high velocities from material surfaces under high strain. The proposed apparatus incorporates currently common optical velocimetry techniques used in shock physics, with interferometric techniques developed to self-stabilize and passively balance interferometers in quantum cryptography. The result is a robust telecom-fiber-based velocimetry system insensitive to modal and frequency dispersion that should work well in the presence of decoherent scattering processes, such as from ejecta clouds and shocked surfaces.

  4. Mathematical Modeling of Chemical Stoichiometry

    ERIC Educational Resources Information Center

    Croteau, Joshua; Fox, William P.; Varazo, Kristofoland

    2007-01-01

    In beginning chemistry classes, students are taught a variety of techniques for balancing chemical equations. The most common method is inspection. This paper addresses using a system of linear mathematical equations to solve for the stoichiometric coefficients. Many linear algebra books carry the standard balancing of chemical equations as an…

  5. Model reduction for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Williams, Trevor

    1992-01-01

    Model reduction is an important practical problem in the control of flexible spacecraft, and a considerable amount of work has been carried out on this topic. Two of the best known methods developed are modal truncation and internal balancing. Modal truncation is simple to implement but can give poor results when the structure possesses clustered natural frequencies, as often occurs in practice. Balancing avoids this problem but has the disadvantages of high computational cost, possible numerical sensitivity problems, and no physical interpretation for the resulting balanced 'modes'. The purpose of this work is to examine the performance of the subsystem balancing technique developed by the investigator when tested on a realistic flexible space structure, in this case a model of the Permanently Manned Configuration (PMC) of Space Station Freedom. This method retains the desirable properties of standard balancing while overcoming the three difficulties listed above. It achieves this by first decomposing the structural model into subsystems of highly correlated modes. Each subsystem is approximately uncorrelated from all others, so balancing them separately and then combining yields comparable results to balancing the entire structure directly. The operation count reduction obtained by the new technique is considerable: a factor of roughly r(exp 2) if the system decomposes into r equal subsystems. Numerical accuracy is also improved significantly, as the matrices being operated on are of reduced dimension, and the modes of the reduced-order model now have a clear physical interpretation; they are, to first order, linear combinations of repeated-frequency modes.

  6. Differential-optoacoustic absorption detector

    NASA Technical Reports Server (NTRS)

    Shumate, M. S.

    1977-01-01

    Two-cell spectrophone detects trace amounts of atmospheric pollutants by measuring absorption coefficients of gases with various laser sources. Device measures pressure difference between two tapered cells with differential manometer. Background signal is reduced by balanced window heating and balanced carrier gas absorption in two cells.

  7. A New Standing Posture Detector to Enable People with Multiple Disabilities to Control Environmental Stimulation by Changing Their Standing Posture through a Commercial Wii Balance Board

    ERIC Educational Resources Information Center

    Shih, Ching-Hsiang; Shih, Ching-Tien; Chiang, Ming-Shan

    2010-01-01

    This study assessed whether two persons with multiple disabilities would be able to control environmental stimulation using body swing (changing standing posture) and a Wii Balance Board with a newly developed standing posture detection program (i.e. a new software program turns a Wii Balance Board into a precise standing posture detector). The…

  8. Life balance and well-being: testing a novel conceptual and measurement approach.

    PubMed

    Sheldon, Kennon M; Cummins, Robert; Kamble, Shanmukh

    2010-08-01

    Although a balanced life has always been viewed as desirable, there are problems with extant conceptualizations and measures of this construct. Here we introduce 2 new life-balance measures, based on time-use profiles, that address these problems. One defines life balance as objectively equitable time use across multiple life domains, and the other defines life balance as low subjective discrepancy between actual and ideal time-use profiles. Study 1 finds that both measures predict concurrent well-being, in both U.S. and Indian samples. Study 2 shows that fluctuations in balance predict fluctuations in well-being over a 3-week period. Study 3 replicates the Study 1 findings using a different time assessment technique, based on the Day Reconstruction Method. Study 4 assigns participants the month-long goal of enhancing their life balance, finding that those who achieve this goal enhance their well-being. In all 4 studies, the balance effects on well-being were mediated by psychological need satisfaction associated with balance.

  9. Lake Chapala change detection using time series

    NASA Astrophysics Data System (ADS)

    López-Caloca, Alejandra; Tapia-Silva, Felipe-Omar; Escalante-Ramírez, Boris

    2008-10-01

    The Lake Chapala is the largest natural lake in Mexico. It presents a hydrological imbalance problem caused by diminishing intakes from the Lerma River, pollution from said volumes, native vegetation and solid waste. This article presents a study that allows us to determine with high precision the extent of the affectation in both extension and volume reduction of the Lake Chapala in the period going from 1990 to 2007. Through satellite images this above-mentioned period was monitored. Image segmentation was achieved through a Markov Random Field model, extending the application towards edge detection. This allows adequately defining the lake's limits as well as determining new zones within the lake, both changes pertaining the Lake Chapala. Detected changes are related to a hydrological balance study based on measuring variables such as storage volumes, evapotranspiration and water balance. Results show that the changes in the Lake Chapala establish frail conditions which pose a future risk situation. Rehabilitation of the lake requires a hydrologic balance in its banks and aquifers.

  10. Evaluating non-detection risk associated with metabarcoding approaches for rare metabarcoding approaches

    EPA Science Inventory

    Early detection of non-indigenous species (NIS), newly introduced species at low abundance in the monitoring area, can strengthen current management strategies including NIS control and eradication. A practical early detection strategy requires achieving balance between efficient...

  11. NASA LaRC Strain Gage Balance Design Concepts

    NASA Technical Reports Server (NTRS)

    Rhew, Ray D.

    1999-01-01

    The NASA Langley Research Center (LaRC) has been designing strain-gage balances for more than fifty years. These balances have been utilized in Langley's wind tunnels, which span over a wide variety of aerodynamic test regimes, as well as other ground based test facilities and in space flight applications. As a result, the designs encompass a large array of sizes, loads, and environmental effects. Currently Langley has more than 300 balances available for its researchers. This paper will focus on the design concepts for internal sting mounted strain-gage balances. However, these techniques can be applied to all force measurement design applications. Strain-gage balance concepts that have been developed over the years including material selection, sting, model interfaces, measuring, sections, fabrication, strain-gaging and calibration will be discussed.

  12. Use of Cognitive Therapy and the Balance Sheet Procedure to Assist Career Decision Making.

    ERIC Educational Resources Information Center

    O'Hare, Marianne M.

    1989-01-01

    A balance sheet technique enables counselors to help clients identify and overcome anxiety associated with career decision making. Steps include describing the problem, brainstorming alternatives, listing expected positive and negative outcomes in terms of self and others, seeking information, and choosing alternatives. (SK)

  13. Identification of sleep bruxism with an ambulatory wireless recording system.

    PubMed

    Inano, Shinji; Mizumori, Takahiro; Kobayashi, Yasuyoshi; Sumiya, Masakazu; Yatani, Hirofumi

    2013-01-01

    To examine whether an ambulatory bruxism recording system, including a biologic monitor, that measures sleep variables and sympatho-vagal balance can specifically identify sleep bruxism (SB) at home. Twenty-six volunteers, including 16 SB subjects, were recruited. Each participant recorded his or her electromyogram (EMG), sympatho-vagal balance, and sound level for 3 consecutive nights using an audio-video recorder to identify SB. Data of sleep variables were compared among the 3 experimental nights. The episodes were classified into SB episodes with and without grinding and non-SB episodes. EMG patterns, amplitude, sympatho-vagal balance, and sound level of all episodes were analyzed so as to determine the appropriate thresholds to detect SB episodes and grinding sound. Then, all episodes without video-recording data were classified into SB and non-SB episodes by using the appropriate thresholds, and the sensitivity and specificity to detect SB episodes were calculated. With regard to sleep variables, there were no significant differences except for sleep latency between the first and second nights. The appropriate EMG pattern and thresholds of amplitude, sympatho-vagal balance, and sound level were phasic or mixed EMG pattern, 20% of maximum voluntary contraction, mean + 1 SD, and mean + 2 SDs, respectively. The sensitivity and specificity to detect SB episodes were 88.4% and 74.2%, respectively. The results suggest that this system enables the detection of SB episodes at home with considerably high accuracy and little interference with sleep.

  14. The Ice Sheet Mass Balance Inter-comparison Exercise

    NASA Astrophysics Data System (ADS)

    Shepherd, A.; Ivins, E. R.

    2015-12-01

    Fluctuations in the mass of ice stored in Antarctica and Greenland are of considerable societal importance. The Ice Sheet Mass Balance Inter-Comparison Exercise (IMBIE) is a joint-initiative of ESA and NASA aimed at producing a single estimate of the global sea level contribution to polar ice sheet losses. Within IMBIE, estimates of ice sheet mass balance are developed from a variety of satellite geodetic techniques using a common spatial and temporal reference frame and a common appreciation of the contributions due to external signals. The project brings together the laboratories and space agencies that have been instrumental in developing independent estimates of ice sheet mass balance to date. In its first phase, IMBIE involved 27 science teams, and delivered a first community assessment of ice sheet mass imbalance to replace 40 individual estimates. The project established that (i) there is good agreement between the three main satellite-based techniques for estimating ice sheet mass balance, (ii) combining satellite data sets leads to significant improvement in certainty, (iii) the polar ice sheets contributed 11 ± 4 mm to global sea levels between 1992 and 2012, and (iv) that combined ice losses from Antarctica and Greenland have increased over time, rising from 10% of the global trend in the early 1990's to 30% in the late 2000's. Demand for an updated assessment has grown, and there are now new satellite missions, new geophysical corrections, new techniques, and new teams producing data. The period of overlap between independent satellite techniques has increased from 5 to 12 years, and the full period of satellite data over which an assessment can be performed has increased from 19 to 40 years. It is also clear that multiple satellite techniques are required to confidently separate mass changes associated with snowfall and ice dynamical imbalance - information that is of critical importance for climate modelling. This presentation outlines the approach for the second phase of IMBIE, including the project organisation, the work programme and schedule, the main science goals, and its current status, and reviews the recent and historical contributions that the Antarctic and Greenland ice sheets have made to global sea level rise.

  15. Task oriented training improves the balance outcome & reducing fall risk in diabetic population.

    PubMed

    Ghazal, Javeria; Malik, Arshad Nawaz; Amjad, Imran

    2016-01-01

    The objective was to determine the balance impairments and to compare task oriented versus traditional balance training in fall reduction among diabetic patients. The randomized control trial with descriptive survey and 196 diabetic patients were recruited to assess balance impairments through purposive sampling technique. Eighteen patients were randomly allocated into two groups; task oriented balance training group TOB (n=8) and traditional balance training group TBT (n=10). The inclusion criteria were 30-50 years age bracket and diagnosed cases of Diabetes Mellitus with neuropathy. The demographics were taken through standardized & valid assessment tools include Berg Balance Scale and Functional Reach Test. The measurements were obtained at baseline, after 04 and 08 weeks of training. The mean age of the participants was 49 ±6.79. The result shows that 165(84%) were at moderate risk of fall and 31(15%) were at mild risk of fall among total 196 diabetic patients. There was significant improvement (p <0.05) in task oriented balance training group for dynamic balance, anticipatory balance and reactive balance after 8 weeks of training as compare to traditional balance training. Task oriented balance training is effective in improving the dynamic, anticipator and reactive balance. The task oriented training reduces the risk of falling through enhancing balance outcome.

  16. Task oriented training improves the balance outcome & reducing fall risk in diabetic population

    PubMed Central

    Ghazal, Javeria; Malik, Arshad Nawaz; Amjad, Imran

    2016-01-01

    Objectives: The objective was to determine the balance impairments and to compare task oriented versus traditional balance training in fall reduction among diabetic patients. Methods: The randomized control trial with descriptive survey and 196 diabetic patients were recruited to assess balance impairments through purposive sampling technique. Eighteen patients were randomly allocated into two groups; task oriented balance training group TOB (n=8) and traditional balance training group TBT (n=10). The inclusion criteria were 30-50 years age bracket and diagnosed cases of Diabetes Mellitus with neuropathy. The demographics were taken through standardized & valid assessment tools include Berg Balance Scale and Functional Reach Test. The measurements were obtained at baseline, after 04 and 08 weeks of training. Results: The mean age of the participants was 49 ±6.79. The result shows that 165(84%) were at moderate risk of fall and 31(15%) were at mild risk of fall among total 196 diabetic patients. There was significant improvement (p <0.05) in task oriented balance training group for dynamic balance, anticipatory balance and reactive balance after 8 weeks of training as compare to traditional balance training. Conclusion: Task oriented balance training is effective in improving the dynamic, anticipator and reactive balance. The task oriented training reduces the risk of falling through enhancing balance outcome. PMID:27648053

  17. Efficacy of virtual reality-based balance training versus the Biodex balance system training on the body balance of adults

    PubMed Central

    Ibrahim, Manal S.; Mattar, Ayman G.; Elhafez, Salam M.

    2016-01-01

    [Purpose] This study investigated efficacy of virtual reality (VR)-based balance training on enhancing balance and postural reactions of adults as a low-cost new modality compared to the established Biodex Balance System (BBS). [Subjects] Thirty normal adults of both genders were divided randomly into two equal-sized experimental groups of 15: BBS balance training and VR balance training. [Methods] The training programmes were conducted in 12 sessions, three 15-min sessions per week. The Nintendo® Wii Fit Plus (NWFP) and its balance board were used to train of the VR group. Each participant answered a questionnaire concerning usability, enjoyment, balance improvement, and fatigue at the end of the training programs. [Results] The study found a significant increase the measure of mean overall balance (OLB) in both groups. No significant difference was found between the groups, but a significant decrease in the mean balance-test time was found for both groups, with no significant difference between the two training methods. The VR programme was rated highly enjoyable by 81.8% of the group. [Conclusion] The Wii Fit Plus system with the balance board as a new VR balance-training technique, can be considered an effective and enjoyable tool for the training of adults’ body balance. PMID:26957722

  18. Characterization and Early Detection of Balance Deficits in Fragile X Premutation Carriers With and Without Fragile X-Associated Tremor/Ataxia Syndrome (FXTAS).

    PubMed

    O'Keefe, Joan A; Robertson-Dick, Erin; Dunn, Emily J; Li, Yan; Deng, Youping; Fiutko, Amber N; Berry-Kravis, Elizabeth; Hall, Deborah A

    2015-12-01

    Fragile X-associated tremor/ataxia syndrome (FXTAS) results from a "premutation" size 55-200 CGG repeat expansion in the fragile X mental retardation 1 (FMR1) gene. Core motor features include cerebellar gait ataxia and kinetic tremor, resulting in progressive mobility disability. There are no published studies characterizing balance deficits in FMR1 premutation carriers with and without FXTAS using a battery of quantitative measures to test the sensory integration underlying postural control, automatic postural reflexes, and dynamic postural stability limits. Computerized dynamic posturography (CDP) and two performance-based balance measures were administered in 44 premutation carriers, 21 with FXTAS and 23 without FXTAS, and 42 healthy controls to compare balance and functional mobility between these groups. Relationships between FMR1 molecular variables, age, and sex and CDP scores were explored. FXTAS subjects demonstrated significantly lower scores on the sensory organization test (with greatest reductions in the vestibular control of balance), longer response latencies to balance perturbations, and reduced stability limits compared to controls. Premutation carriers without FXTAS also demonstrated significantly delayed response latencies and disrupted sensory weighting for balance control. Advancing age, male sex, increased CGG repeat size, and reduced X activation of the normal allele in premutation carrier women predicted balance dysfunction. These postural control deficits in carriers with and without FXTAS implicate dysfunctional cerebellar neural networks and may provide valuable outcome markers for tailored rehabilitative interventions. Our findings suggest that CDP may provide sensitive measures for early detection of postural control impairments in at-risk carriers and better characterize balance dysfunction and progression in FXTAS.

  19. Optimal Stimulus Amplitude for Vestibular Stochastic Stimulation to Improve Sensorimotor Function

    NASA Technical Reports Server (NTRS)

    Goel, R.; Kofman, I.; DeDios, Y. E.; Jeevarajan, J.; Stepanyan, V.; Nair, M.; Congdon, S.; Fregia, M.; Cohen, H.; Bloomberg, J. J.; hide

    2014-01-01

    Sensorimotor changes such as postural and gait instabilities can affect the functional performance of astronauts when they transition across different gravity environments. We are developing a method, based on stochastic resonance (SR), to enhance information transfer by applying non-zero levels of external noise on the vestibular system (vestibular stochastic resonance, VSR). Our previous work has shown the advantageous effects of VSR in a balance task of standing on an unstable surface. This technique to improve detection of vestibular signals uses a stimulus delivery system that is wearable or portable and provides imperceptibly low levels of white noise-based binaural bipolar electrical stimulation of the vestibular system. The goal of this project is to determine optimal levels of stimulation for SR applications by using a defined vestibular threshold of motion detection. A series of experiments were carried out to determine a robust paradigm to identify a vestibular threshold that can then be used to recommend optimal stimulation levels for SR training applications customized to each crewmember. Customizing stimulus intensity can maximize treatment effects. The amplitude of stimulation to be used in the VSR application has varied across studies in the literature such as 60% of nociceptive stimulus thresholds. We compared subjects' perceptual threshold with that obtained from two measures of body sway. Each test session was 463s long and consisted of several 15s sinusoidal stimuli, at different current amplitudes (0-2 mA), interspersed with 20-20.5s periods of no stimulation. Subjects sat on a chair with their eyes closed and had to report their perception of motion through a joystick. A force plate underneath the chair recorded medio-lateral shear forces and roll moments. First we determined the percent time during stimulation periods for which perception of motion (activity above a pre-defined threshold) was reported using the joystick, and body sway (two standard deviation of the noise level in the baseline measurement) was detected by the sensors. The percentage time at each stimulation level for motion detection was normalized with respect to the largest value and a logistic regression curve fit was applied to these data. The threshold was defined at the 50% probability of motion detection. Comparison of threshold of motion detection obtained from joystick data versus body sway suggests that perceptual thresholds were significantly lower, and were not impacted by system noise. Further, in order to determine optimal stimulation amplitude to improve balance, two sets of experiments were carried out. In the first set of experiments, all subjects received the same level of stimuli and the intensity of optimal performance was projected back on subjects' vestibular threshold curve. In the second set of experiments, on different subjects, stimulation was administered from 20-400% of subjects' vestibular threshold obtained from joystick data. Preliminary results of our study show that, in general, using stimulation amplitudes at 40-60% of perceptual motion threshold improved balance performance significantly compared to control (no stimulation). The amplitude of vestibular stimulation that improved balance function was predominantly in the range of +/- 100 to +/- 400 micro A. We hypothesize that VSR stimulation will act synergistically with sensorimotor adaptability (SA) training to improve adaptability by increasing utilization of vestibular information and therefore will help us to optimize and personalize a SA countermeasure prescription. This combination will help to significantly reduce the number of days required to recover functional performance to preflight levels after long-duration spaceflight.

  20. Working Sandwich Generation Women Utilize Strategies within and between Roles to Achieve Role Balance.

    PubMed

    Evans, Kiah L; Millsteed, Jeannine; Richmond, Janet E; Falkmer, Marita; Falkmer, Torbjorn; Girdler, Sonya J

    2016-01-01

    Increasingly, women simultaneously balance the roles of mother, parental carer and worker. However, individual role balance strategies among these working 'sandwich' generation women have not been thoroughly explored. Eighteen women combining these three roles were interviewed about their individual role balance strategies. Findings were identified through the framework analysis technique, underpinned by the Model of Juggling Occupations. Achieving and maintaining role balance was explained as a complex process accomplished through a range of strategies. Findings revealed the women used six within-role balance strategies: living with integrity, being the best you can, doing what you love, loving what you do, remembering why and searching for signs of success. The women also described six between-role balance strategies: maintaining health and wellbeing, repressing perfectionism, managing time and energy, releasing responsibility, nurturing social connection and reciprocating. These findings provide a basis for health care providers to understand and potentially support working 'sandwich' generation women.

  1. A single-stage optical load-balanced switch for data centers.

    PubMed

    Huang, Qirui; Yeo, Yong-Kee; Zhou, Luying

    2012-10-22

    Load balancing is an attractive technique to achieve maximum throughput and optimal resource utilization in large-scale switching systems. However current electronic load-balanced switches suffer from severe problems in implementation cost, power consumption and scaling. To overcome these problems, in this paper we propose a single-stage optical load-balanced switch architecture based on an arrayed waveguide grating router (AWGR) in conjunction with fast tunable lasers. By reuse of the fast tunable lasers, the switch achieves both functions of load balancing and switching through the AWGR. With this architecture, proof-of-concept experiments have been conducted to investigate the feasibility of the optical load-balanced switch and to examine its physical performance. Compared to three-stage load-balanced switches, the reported switch needs only half of optical devices such as tunable lasers and AWGRs, which can provide a cost-effective solution for future data centers.

  2. Numerical dispersion compensation for Partial Coherence Interferometry and Optical Coherence Tomography.

    PubMed

    Fercher, A; Hitzenberger, C; Sticker, M; Zawadzki, R; Karamata, B; Lasser, T

    2001-12-03

    Dispersive samples introduce a wavelength dependent phase distortion to the probe beam. This leads to a noticeable loss of depth resolution in high resolution OCT using broadband light sources. The standard technique to avoid this consequence is to balance the dispersion of the sample byarrangingadispersive materialinthereference arm. However, the impact of dispersion is depth dependent. A corresponding depth dependent dispersion balancing technique is diffcult to implement. Here we present a numerical dispersion compensation technique for Partial Coherence Interferometry (PCI) and Optical Coherence Tomography (OCT) based on numerical correlation of the depth scan signal with a depth variant kernel. It can be used a posteriori and provides depth dependent dispersion compensation. Examples of dispersion compensated depth scan signals obtained from microscope cover glasses are presented.

  3. The effect of surface conditions on the work function of insulators and semiconductors

    NASA Technical Reports Server (NTRS)

    George, A.

    1973-01-01

    Ionization energies of organic semiconductors were determined using single crystals of the material. The theory of the method is essentially that of Millikan's oil drop experiment. The technique employed in the experiment is based on the electrostatic method of balancing a charged particle in an electric field against the force of gravity for different excitation energies above the threshold value, and from an estimate of the balancing voltages, read off the ionization energy from the intercept of the energy axis in a plot wavelength corresponding to the balancing potential for the incident radiation of wavelength. In the modified technique which is adopted in the present experimental investigation, a small single crystal is suspended by a fine quartz fiber between two vertical capacitor plates to which a suitable high voltage is applied.

  4. Very high resolution surface mass balance over Greenland modeled by the regional climate model MAR with a downscaling technique

    NASA Astrophysics Data System (ADS)

    Kittel, Christoph; Lang, Charlotte; Agosta, Cécile; Prignon, Maxime; Fettweis, Xavier; Erpicum, Michel

    2016-04-01

    This study presents surface mass balance (SMB) results at 5 km resolution with the regional climate MAR model over the Greenland ice sheet. Here, we use the last MAR version (v3.6) where the land-ice module (SISVAT) using a high resolution grid (5km) for surface variables is fully coupled while the MAR atmospheric module running at a lower resolution of 10km. This online downscaling technique enables to correct near-surface temperature and humidity from MAR by a gradient based on elevation before forcing SISVAT. The 10 km precipitation is not corrected. Corrections are stronger over the ablation zone where topography presents more variations. The model has been force by ERA-Interim between 1979 and 2014. We will show the advantages of using an online SMB downscaling technique in respect to an offline downscaling extrapolation based on local SMB vertical gradients. Results at 5 km show a better agreement with the PROMICE surface mass balance data base than the extrapolated 10 km MAR SMB results.

  5. Robust multiperson detection and tracking for mobile service and social robots.

    PubMed

    Li, Liyuan; Yan, Shuicheng; Yu, Xinguo; Tan, Yeow Kee; Li, Haizhou

    2012-10-01

    This paper proposes an efficient system which integrates multiple vision models for robust multiperson detection and tracking for mobile service and social robots in public environments. The core technique is a novel maximum likelihood (ML)-based algorithm which combines the multimodel detections in mean-shift tracking. First, a likelihood probability which integrates detections and similarity to local appearance is defined. Then, an expectation-maximization (EM)-like mean-shift algorithm is derived under the ML framework. In each iteration, the E-step estimates the associations to the detections, and the M-step locates the new position according to the ML criterion. To be robust to the complex crowded scenarios for multiperson tracking, an improved sequential strategy to perform the mean-shift tracking is proposed. Under this strategy, human objects are tracked sequentially according to their priority order. To balance the efficiency and robustness for real-time performance, at each stage, the first two objects from the list of the priority order are tested, and the one with the higher score is selected. The proposed method has been successfully implemented on real-world service and social robots. The vision system integrates stereo-based and histograms-of-oriented-gradients-based human detections, occlusion reasoning, and sequential mean-shift tracking. Various examples to show the advantages and robustness of the proposed system for multiperson tracking from mobile robots are presented. Quantitative evaluations on the performance of multiperson tracking are also performed. Experimental results indicate that significant improvements have been achieved by using the proposed method.

  6. Visual Data Exploration for Balance Quantification in Real-Time During Exergaming.

    PubMed

    Soancatl Aguilar, Venustiano; J van de Gronde, Jasper; J C Lamoth, Claudine; van Diest, Mike; M Maurits, Natasha; B T M Roerdink, Jos

    2017-01-01

    Unintentional injuries are among the ten leading causes of death in older adults; falls cause 60% of these deaths. Despite their effectiveness to improve balance and reduce the risk of falls, balance training programs have several drawbacks in practice, such as lack of engaging elements, boring exercises, and the effort and cost of travelling, ultimately resulting in low adherence. Exergames, that is, digital games controlled by body movements, have been proposed as an alternative to improve balance. One of the main challenges for exergames is to automatically quantify balance during game-play in order to adapt the game difficulty according to the skills of the player. Here we perform a multidimensional exploratory data analysis, using visualization techniques, to find useful measures for quantifying balance in real-time. First, we visualize exergaming data, derived from 400 force plate recordings of 40 participants from 20 to 79 years and 10 trials per participant, as heat maps and violin plots to get quick insight into the nature of the data. Second, we extract known and new features from the data, such as instantaneous speed, measures of dispersion, turbulence measures derived from speed, and curvature values. Finally, we analyze and visualize these features using several visualizations such as a heat map, overlapping violin plots, a parallel coordinate plot, a projection of the two first principal components, and a scatter plot matrix. Our visualizations and findings suggest that heat maps and violin plots can provide quick insight and directions for further data exploration. The most promising measures to quantify balance in real-time are speed, curvature and a turbulence measure, because these measures show age-related changes in balance performance. The next step is to apply the present techniques to data of whole body movements as recorded by devices such as Kinect.

  7. Visual Data Exploration for Balance Quantification in Real-Time During Exergaming

    PubMed Central

    J. van de Gronde, Jasper; J. C. Lamoth, Claudine; van Diest, Mike; M. Maurits, Natasha; B. T. M. Roerdink, Jos

    2017-01-01

    Unintentional injuries are among the ten leading causes of death in older adults; falls cause 60% of these deaths. Despite their effectiveness to improve balance and reduce the risk of falls, balance training programs have several drawbacks in practice, such as lack of engaging elements, boring exercises, and the effort and cost of travelling, ultimately resulting in low adherence. Exergames, that is, digital games controlled by body movements, have been proposed as an alternative to improve balance. One of the main challenges for exergames is to automatically quantify balance during game-play in order to adapt the game difficulty according to the skills of the player. Here we perform a multidimensional exploratory data analysis, using visualization techniques, to find useful measures for quantifying balance in real-time. First, we visualize exergaming data, derived from 400 force plate recordings of 40 participants from 20 to 79 years and 10 trials per participant, as heat maps and violin plots to get quick insight into the nature of the data. Second, we extract known and new features from the data, such as instantaneous speed, measures of dispersion, turbulence measures derived from speed, and curvature values. Finally, we analyze and visualize these features using several visualizations such as a heat map, overlapping violin plots, a parallel coordinate plot, a projection of the two first principal components, and a scatter plot matrix. Our visualizations and findings suggest that heat maps and violin plots can provide quick insight and directions for further data exploration. The most promising measures to quantify balance in real-time are speed, curvature and a turbulence measure, because these measures show age-related changes in balance performance. The next step is to apply the present techniques to data of whole body movements as recorded by devices such as Kinect. PMID:28135284

  8. Balancing Detection and Eradication for Control of Epidemics: Sudden Oak Death in Mixed-Species Stands

    PubMed Central

    Ndeffo Mbah, Martial L.; Gilligan, Christopher A.

    2010-01-01

    Culling of infected individuals is a widely used measure for the control of several plant and animal pathogens but culling first requires detection of often cryptically-infected hosts. In this paper, we address the problem of how to allocate resources between detection and culling when the budget for disease management is limited. The results are generic but we motivate the problem for the control of a botanical epidemic in a natural ecosystem: sudden oak death in mixed evergreen forests in coastal California, in which species composition is generally dominated by a spreader species (bay laurel) and a second host species (coast live oak) that is an epidemiological dead-end in that it does not transmit infection but which is frequently a target for preservation. Using a combination of an epidemiological model for two host species with a common pathogen together with optimal control theory we address the problem of how to balance the allocation of resources for detection and epidemic control in order to preserve both host species in the ecosystem. Contrary to simple expectations our results show that an intermediate level of detection is optimal. Low levels of detection, characteristic of low effort expended on searching and detection of diseased trees, and high detection levels, exemplified by the deployment of large amounts of resources to identify diseased trees, fail to bring the epidemic under control. Importantly, we show that a slight change in the balance between the resources allocated to detection and those allocated to control may lead to drastic inefficiencies in control strategies. The results hold when quarantine is introduced to reduce the ingress of infected material into the region of interest. PMID:20856850

  9. Virtual containment system for composite flywheels

    NASA Astrophysics Data System (ADS)

    Shiue, Fuh-Wen

    2001-07-01

    There is much interest in advanced composite flywheel systems for use on satellites mainly because of the potential for considerable weight savings associated with combined energy and momentum management. The additional weight of a containment system needed to protect the satellite in the event of a flywheel failure, however, could negate the potential savings. Therefore, the development of a condition monitoring and virtual containment system is essential to ensure the wide acceptance of flywheel batteries for spacecraft applications. A virtual containment system is a near real-time condition monitoring system, plus additional logic to adjust the operating conditions (maximum rotational speed) accordingly when a flaw or fault is detected. Flaws of primary interest in this study are those unique to composite flywheels, such as delamination and debonding of interfaces. Such flaws change the balance state of a flywheel through small, but detectable, motion of the mass center and principal axes of inertia. A proposed monitoring technique determines the existence and the extent of such flaws by a method similar to the influence-coefficient rotor balancing method. Because of the speed-dependence of the imbalance caused by elastic flaws, a normalized imbalance change, which is a direct measure of the flaw size, was defined. To account for the possibility that flaw growth could actually improve the balance state of a rotor, a new concept of accumulated imbalance change was also introduced. Laboratory tests showed the proposed method was able to detect small simulated flaws that result in as little as 2--3 microns of mass center movement. Fracture mechanics concepts were used to evaluate the severity and growth rate of the detected flaw. An interesting discovery that coincided with some experimental observations reported in the literature was the energy release rate reduction with a large crack. This finding indicates a possible stress relief and crack arrest when a circumferential crack grows over certain size. This phenomenon is largely due to crack curvature unique to filament-wound composite flywheels. Several virtual containment strategies were investigated numerically to demonstrate the feasibility of virtual containment systems. Once a flaw is detected during flywheel operation, the maximum operating speed can be reduced to prevent catastrophic failure, achieve a specific design life, and maximize energy storage capacity over the remaining life. A numerical example showed 4--5 times of improvement in cumulative energy storage through lifetime with a virtual containment. A closed-loop speed controller using condition monitoring sensor feedback was investigated numerically to account for possible imperfection of the fracture mechanics model. Finally, an integrated virtual containment system without any complex fracture mechanics analysis was also developed and successfully demonstrated experimentally.

  10. An improved NSGA - II algorithm for mixed model assembly line balancing

    NASA Astrophysics Data System (ADS)

    Wu, Yongming; Xu, Yanxia; Luo, Lifei; Zhang, Han; Zhao, Xudong

    2018-05-01

    Aiming at the problems of assembly line balancing and path optimization for material vehicles in mixed model manufacturing system, a multi-objective mixed model assembly line (MMAL), which is based on optimization objectives, influencing factors and constraints, is established. According to the specific situation, an improved NSGA-II algorithm based on ecological evolution strategy is designed. An environment self-detecting operator, which is used to detect whether the environment changes, is adopted in the algorithm. Finally, the effectiveness of proposed model and algorithm is verified by examples in a concrete mixing system.

  11. The balanced scorecard: an incremental approach model to health care management.

    PubMed

    Pineno, Charles J

    2002-01-01

    The balanced scorecard represents a technique used in strategic management to translate an organization's mission and strategy into a comprehensive set of performance measures that provide the framework for implementation of strategic management. This article develops an incremental approach for decision making by formulating a specific balanced scorecard model with an index of nonfinancial as well as financial measures. The incremental approach to costs, including profit contribution analysis and probabilities, allows decisionmakers to assess, for example, how their desire to meet different health care needs will cause changes in service design. This incremental approach to the balanced scorecard may prove to be useful in evaluating the existence of causality relationships between different objective and subjective measures to be included within the balanced scorecard.

  12. Automatic computation and solution of generalized harmonic balance equations

    NASA Astrophysics Data System (ADS)

    Peyton Jones, J. C.; Yaser, K. S. A.; Stevenson, J.

    2018-02-01

    Generalized methods are presented for generating and solving the harmonic balance equations for a broad class of nonlinear differential or difference equations and for a general set of harmonics chosen by the user. In particular, a new algorithm for automatically generating the Jacobian of the balance equations enables efficient solution of these equations using continuation methods. Efficient numeric validation techniques are also presented, and the combined algorithm is applied to the analysis of dc, fundamental, second and third harmonic response of a nonlinear automotive damper.

  13. Multi-Plane High Speed Balancing Techniques and the Use of a High Specific Stiffness Ti-Borsic Material for Vibration Control.

    DTIC Science & Technology

    1980-02-01

    maneuver conditions, and transmit the net axial thrust force between the turbine and fan sections due to pressure and aero dynamic gas loads . 49 Lm...stiffness composite material shaft. Both~~ balancing demonstration and the composite shaft design ad as their objective the management of small turbofan ...CONFIGURATIONS 99 LIST OF ILLUSTRATIONS Figure Title Page 1 High Speed Balancing Program Schedule 4 2 Teledyne CAE Model 471-11DX Turbofan Engine

  14. HDR imaging and color constancy: two sides of the same coin?

    NASA Astrophysics Data System (ADS)

    McCann, John J.

    2011-01-01

    At first, we think that High Dynamic Range (HDR) imaging is a technique for improved recordings of scene radiances. Many of us think that human color constancy is a variation of a camera's automatic white balance algorithm. However, on closer inspection, glare limits the range of light we can detect in cameras and on retinas. All scene regions below middle gray are influenced, more or less, by the glare from the bright scene segments. Instead of accurate radiance reproduction, HDR imaging works well because it preserves the details in the scene's spatial contrast. Similarly, on closer inspection, human color constancy depends on spatial comparisons that synthesize appearances from all the scene segments. Can spatial image processing play similar principle roles in both HDR imaging and color constancy?

  15. Nlgn4 knockout induces network hypo-excitability in juvenile mouse somatosensory cortex in vitro.

    PubMed

    Delattre, V; La Mendola, D; Meystre, J; Markram, H; Markram, K

    2013-10-09

    Neuroligins (Nlgns) are postsynaptic cell adhesion molecules that form transynaptic complexes with presynaptic neurexins and regulate synapse maturation and plasticity. We studied the impact of the loss of Nlgn4 on the excitatory and inhibitory circuits in somatosensory cortical slices of juvenile mice by electrically stimulating these circuits using a multi-electrode array and recording the synaptic input to single neurons using the patch-clamp technique. We detected a decreased network response to stimulation in both excitatory and inhibitory circuits of Nlgn4 knock-out animals as compared to wild-type controls, and a decreased excitation-inhibition ratio. These data indicate that Nlgn4 is involved in the regulation of excitatory and inhibitory circuits and contributes to a balanced circuit response to stimulation.

  16. Soft tissue balance changes depending on joint distraction force in total knee arthroplasty.

    PubMed

    Nagai, Kanto; Muratsu, Hirotsugu; Matsumoto, Tomoyuki; Miya, Hidetoshi; Kuroda, Ryosuke; Kurosaka, Masahiro

    2014-03-01

    The influence of joint distraction force on intraoperative soft tissue balance was evaluated using Offset Repo-Tensor® for 78 knees that underwent primary posterior-stabilized total knee arthroplasty. The joint center gap and varus ligament balance were measured between osteotomized surfaces using 20, 40 and 60 lbs of joint distraction force. These values were significantly increased at extension and flexion as the distraction force increased. Furthermore, lateral compartment stiffness was significantly lower than medial compartment stiffness. Thus, larger joint distraction forces led to larger varus ligament balance and joint center gap, because of the difference in soft tissue stiffness between lateral and medial compartments. These findings indicate the importance of the strength of joint distraction force in the assessment of soft tissue balance, especially when using gap-balancing technique. © 2014.

  17. A forecast of new test capabilities using Magnetic Suspension and Balance Systems

    NASA Technical Reports Server (NTRS)

    Lawing, Pierce L.; Johnson, William G., Jr.

    1988-01-01

    This paper outlines the potential of Magnetic Suspension and Balance System (MSBS) technology to solve existing problems related to support interference in wind tunnels. Improvement of existing test techniques and exciting new techniques are envisioned as a result of applying MSBS. These include improved data accuracy, dynamic stability testing, two-body/stores release testing, and pilot/designer-in-the-loop tests. It also discusses the use of MSBS for testing exotic configurations such as hybrid hypersonic vehicles. A new facility concept that combines features of ballistic tubes, magnetic suspension, and cryogenic tunnels is described.

  18. Monitoring southwest Greenland's ice sheet melt with ambient seismic noise.

    PubMed

    Mordret, Aurélien; Mikesell, T Dylan; Harig, Christopher; Lipovsky, Bradley P; Prieto, Germán A

    2016-05-01

    The Greenland ice sheet presently accounts for ~70% of global ice sheet mass loss. Because this mass loss is associated with sea-level rise at a rate of 0.7 mm/year, the development of improved monitoring techniques to observe ongoing changes in ice sheet mass balance is of paramount concern. Spaceborne mass balance techniques are commonly used; however, they are inadequate for many purposes because of their low spatial and/or temporal resolution. We demonstrate that small variations in seismic wave speed in Earth's crust, as measured with the correlation of seismic noise, may be used to infer seasonal ice sheet mass balance. Seasonal loading and unloading of glacial mass induces strain in the crust, and these strains then result in seismic velocity changes due to poroelastic processes. Our method provides a new and independent way of monitoring (in near real time) ice sheet mass balance, yielding new constraints on ice sheet evolution and its contribution to global sea-level changes. An increased number of seismic stations in the vicinity of ice sheets will enhance our ability to create detailed space-time records of ice mass variations.

  19. Improving Sensorimotor Adaptation Following Long Duration Space Flight by Enhancing Vestibular Information Transfer

    NASA Technical Reports Server (NTRS)

    Mulavara, A. P.; Kofman, I. S.; De Dios, Y. E; Galvan, R.; Goel, R.; Miller, C.; Peters, B.; Cohen, H. S.; Jeevarajan, J.; Reschke, M.; hide

    2014-01-01

    Crewmember adapted to the microgravity state may need to egress the vehicle within a few minutes for safety and operational reasons after gravitational transitions. The transition from one sensorimotor state to another consists of two main mechanisms: strategic and plastic-adaptive and have been demonstrated in astronauts returning after long duration space flight. Strategic modifications represent "early adaptation" - immediate and transitory changes in control that are employed to deal with short-term changes in the environment. If these modifications are prolonged then plastic-adaptive changes are evoked that modify central nervous system function, automating new behavioral responses. More importantly, this longer term adaptive recovery mechanism was significantly associated with their strategic ability to recover on the first day after return to Earth G. We are developing a method based on stochastic resonance to enhance information transfer by improving the brain's ability to detect vestibular signals (Vestibular Stochastic Resonance, VSR) especially when combined with balance training exercises such as sensorimotor adaptability (SA) training for rapid improvement in functional skill, for standing and mobility. This countermeasure to improve detection of vestibular signals is a stimulus delivery system that is wearable/portable providing low imperceptible levels of white noise based binaural bipolar electrical stimulation of the vestibular system (stochastic vestibular stimulation). To determine efficacy of vestibular stimulation on physiological and perceptual responses during otolith-canal conflicts and dynamic perturbations we have conducted a series of studies: We have shown that imperceptible binaural bipolar electrical stimulation of the vestibular system across the mastoids enhances balance performance in the mediolateral (ML) plane while standing on an unstable surface. We have followed up on the previous study showing VSR stimulation improved balance performance in both ML and anteroposterior planes while stimulating in the ML axis only. We have shown the efficacy of VSR stimulations on enhancing physiological and perceptual responses of whole-body orientation during low frequency perturbations (0.1 Hz) on the ocular motor system using a variable radius centrifuge on both physiological (using eye movements) and perceptual responses (using a joystick) to track imposed oscillations. The variable radius centrifuge provides a selective tilting sensation that is detectable only by the otolith organs providing conflicting information from the canal organs of the vestibular system (intra-vestibular conflict). These results indicate that VSR can improve performance in sensory conflict scenarios like that experienced during space flight. We have showed the efficacy of VSR stimulation to improve balance and locomotor control on subjects exposed to continuous, sinusoidal lateral motion of the support surface while walking on a treadmill while viewing perceptually matched linear optic flow. We have shown the safety of short term continuous use of up to 4 hours of VSR stimulation and its efficacy in improving balance and locomotor function in Parkinson's Disease patients. This technique for improving vestibular signal detection may thus provide additional information to improve strategic abilities. We hypothesize that VSR stimulation will act synergistically with SA training to improve adaptability by increased utilization of vestibular information and therefore serve to optimize and personalize the SA countermeasure prescription. This forms the basis of its usefulness both as a training modality and further help in significantly reducing the number of days required to recover functional performance to preflight levels after long duration space flight.

  20. Ethnic Differences in Decisional Balance and Stages of Mammography Adoption

    ERIC Educational Resources Information Center

    Otero-Sabogal, Regina; Stewart, Susan; Shema, Sarah J.; Pasick, Rena J.

    2007-01-01

    Behavioral theories developed through research with mainstream, English-speaking populations have been applied to ethnically diverse and underserved communities in the effort to eliminate disparities in early breast cancer detection. This study tests the validity of the transtheoretical model (TTM) decisional balance measure and the application of…

  1. A novel load balanced energy conservation approach in WSN using biogeography based optimization

    NASA Astrophysics Data System (ADS)

    Kaushik, Ajay; Indu, S.; Gupta, Daya

    2017-09-01

    Clustering sensor nodes is an effective technique to reduce energy consumption of the sensor nodes and maximize the lifetime of Wireless sensor networks. Balancing load of the cluster head is an important factor in long run operation of WSNs. In this paper we propose a novel load balancing approach using biogeography based optimization (LB-BBO). LB-BBO uses two separate fitness functions to perform load balancing of equal and unequal load respectively. The proposed method is simulated using matlab and compared with existing methods. The proposed method shows better performance than all the previous works implemented for energy conservation in WSN

  2. Wavelet-frequency analysis for the detection of discontinuities in switched system models of human balance.

    PubMed

    Nema, Salam; Kowalczyk, Piotr; Loram, Ian

    2017-01-01

    This paper is concerned with detecting the presence of switching behavior in experimentally obtained posturographic data sets by means of a novel algorithm that is based on a combination of wavelet analysis and Hilbert transform. As a test-bed for the algorithm, we first use a switched model of human balance control during quiet standing with known switching behavior in four distinct configurations. We obtain a time-frequency representation of a signal generated by our model system. We are then able to detect manifestations of discontinuities (switchings) in the signal as spiking behavior. The frequency of switchings, measured by means of our algorithm and detected in our models systems, agrees with the frequency of spiking behavior found in the experimentally obtained posturographic data. Copyright © 2016. Published by Elsevier B.V.

  3. Balance and mobility dysfunction and falls risk in older people with mild to moderate Alzheimer disease.

    PubMed

    Suttanon, Plaiwan; Hill, Keith D; Said, Catherine M; Logiudice, Dina; Lautenschlager, Nicola T; Dodd, Karen J

    2012-01-01

    This study aimed to identify the magnitude and type of balance and mobility impairments in people with Alzheimer disease by comparing their performance with that of older people without cognitive impairment. Twenty-five community-dwelling people with mild to moderate Alzheimer disease and a comparison group of 25 cognitively intact age- and sex-matched people completed a comprehensive balance and mobility assessment. This included computerized posturography measures of static and dynamic balance under various conditions, clinical balance, and mobility measures, and measures of falls and falls risk. The level of falls risk was higher in people with Alzheimer disease. Standing balance in people with Alzheimer disease was significantly impaired across a range of static and dynamic balance conditions. Activity level, gait, and mobility measures were also impaired, particularly turning and dual tasks. The findings of the study highlight the value of including balance screening as a routine component of early dementia assessment. This would allow for the early detection of balance dysfunction and the introduction of balance retraining before impairments progress to more advanced levels.

  4. Balance Training Versus Balance Training With STARS in Patients With Chronic Ankle Instability: A Randomized Controlled Trial.

    PubMed

    Burcal, Christopher J; Trier, Alejandra Y; Wikstrom, Erik A

    2017-09-01

    Both balance training and selected interventions meant to target sensory structures (STARS) have been shown to be effective at restoring deficits associated with chronic ankle instability (CAI). Clinicians often use multiple treatment modalities in patients with CAI. However, evidence for combined intervention effectiveness in CAI patients remains limited. To determine if augmenting a balance-training protocol with STARS (BTS) results in greater improvements than balance training (BT) alone in those with CAI. Randomized-controlled trial. Research laboratory. 24 CAI participants (age 21.3 ± 2.0 y; height 169.8 ± 12.9 cm; mass 72.5 ± 22.2 kg) were randomized into 2 groups: BT and BTS. Participants completed a 4-week progression-based balance-training protocol consisting of 3 20-min sessions per week. The experimental group also received a 5-min set of STARS treatments consisting of calf stretching, plantar massage, ankle joint mobilizations, and ankle joint traction before each balance-training session. Outcomes included self-assessed disability, Star Excursion Balance Test reach distance, and time-to-boundary calculated from static balance trials. All outcomes were assessed before, and 24-hours and 1-week after protocol completion. Self-assessed disability was also captured 1-month after the intervention. No significant group differences were identified (P > .10). Both groups demonstrated improvements in all outcome categories after the interventions (P < .10), many of which were retained at 1-week posttest (P < .10). Although 90% CIs include zero, effect sizes favor BTS. Similarly, only the BTS group exceeded the minimal detectable change for time-to-boundary outcomes. While statistically no more effective, exceeding minimal detectable change scores and favorable effect sizes suggest that a 4-week progressive BTS program may be more effective at improving self-assessed disability and postural control in CAI patients than balance training in isolation.

  5. 31 CFR 205.12 - What funding techniques may be used?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false What funding techniques may be used? 205.12 Section 205.12 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... technique upon which both parties agree. (1) Zero balance accounting means that a Federal Program Agency...

  6. Teaching Techniques in Clinical Chemistry.

    ERIC Educational Resources Information Center

    Wilson, Diane

    This master's thesis presents several instructional methods and techniques developed for each of eleven topics or subject areas in clinical chemistry: carbohydrate metabolism, lipid metabolism, diagnostic enzymology, endocrinology, toxicology, quality control, electrolytes, acid base balance, hepatic function, nonprotein nitrogenous compounds, and…

  7. Reactive Tracer Techniques to Quantitatively Monitor Carbon Dioxide Storage in Geologic Formations

    NASA Astrophysics Data System (ADS)

    Matter, J. M.; Carson, C.; Stute, M.; Broecker, W. S.

    2012-12-01

    Injection of CO2 into geologic storage reservoirs induces fluid-rock reactions that may lead to the mineralization of the injected CO2. The long-term safety of geologic CO2 storage is, therefore, determined by in situ CO2-fluid-rock reactions. Currently existing monitoring and verification techniques for CO2 storage are insufficient to characterize the solubility and reactivity of the injected CO2, and to establish a mass balance of the stored CO2. Dissolved and chemically transformed CO2 thus avoid detection. We developed and are testing a new reactive tracer technique for quantitative monitoring and detection of dissolved and chemically transformed CO2 in geologic storage reservoirs. The technique involves tagging the injected carbon with radiocarbon (14C). Carbon-14 is a naturally occurring radioisotope produced by cosmic radiation and made artificially by 14N neutron capture. The ambient concentration is very low with a 14C/12C ratio of 10-12. The concentration of 14C in deep geologic formations and fossil fuels is at least two orders of magnitude lower. This makes 14C an ideal quantitative tracer for tagging underground injections of anthropogenic CO2. We are testing the feasibility of this tracer technique at the CarbFix pilot injection site in Iceland, where approximately 2,000 tons of CO2 dissolved in water are currently injected into a deep basalt aquifer. The injected CO2 is tagged with 14C by dynamically adding calibrated amounts of H14CO3 solution to the injection stream. The target concentration is 12 Bq/kg of injected water, which results in a 14C activity that is 5 times enriched compared to the 1850 background. In addition to 14C as a reactive tracer, trifluormethylsulphur pentafluoride (SF5CF3) and sulfurhexafluoride (SF6) are used as conservative tracers to monitor the transport of the injected CO2 in the subsurface. Fluid samples are collected for tracer analysis from the injection and monitoring wells on a regular basis. Results show a fast reaction of the injected CO2 with the ambient reservoir fluid and rocks. Mixing and in situ CO2-water-rock reactions are detected by changes in the different tracer ratios. The feasibility of 14C as a reactive tracer for geologic CO2 storage also depends on the analytical technique used to measure 14C activities. Currently, 14C is analyzed using Accelerator Mass Spectrometery (AMS), which is expensive and requires centralized facilities. To enable real time online monitoring and verification, we are developing an alternative detection method for radiocarbon. The IntraCavity OptoGalvanic Spectroscopy (ICOGS) system is using a CO2 laser to detect carbon isotope ratios at environmental levels. Results from our prototype of this bench-top technology demonstrate that an ICOGS system can be used in a continuous mode with analysis times of the order of minutes, and can deliver data of similar quality as AMS.

  8. System engineering techniques for establishing balanced design and performance guidelines for the advanced telerobotic testbed

    NASA Technical Reports Server (NTRS)

    Zimmerman, W. F.; Matijevic, J. R.

    1987-01-01

    Novel system engineering techniques have been developed and applied to establishing structured design and performance objectives for the Telerobotics Testbed that reduce technical risk while still allowing the testbed to demonstrate an advancement in state-of-the-art robotic technologies. To estblish the appropriate tradeoff structure and balance of technology performance against technical risk, an analytical data base was developed which drew on: (1) automation/robot-technology availability projections, (2) typical or potential application mission task sets, (3) performance simulations, (4) project schedule constraints, and (5) project funding constraints. Design tradeoffs and configuration/performance iterations were conducted by comparing feasible technology/task set configurations against schedule/budget constraints as well as original program target technology objectives. The final system configuration, task set, and technology set reflected a balanced advancement in state-of-the-art robotic technologies, while meeting programmatic objectives and schedule/cost constraints.

  9. Preliminary measurement of gas concentrations of perfluropropane using an analytical weighing balance.

    PubMed

    Clarkson, Douglas McG; Manna, Avinish; Hero, Mark

    2014-02-01

    We describe the use of an analytical weighing balance of measurement accuracy 0.00001g for determination of concentrations of perfluropropane (C3F8) gas used in ophthalmic surgical vitrectomy procedures. A range of test eyes corresponding to an eye volume of 6.1ml were constructed using 27 gauge needle exit ducts and separately 20 gauge (straight) and 23 gauge (angled) entrance ports. This method allowed determination of concentration levels in the sample preparation syringe and also levels in test eyes. It was determined that a key factor influencing gas concentrations accuracy related to the method of gas fill and the value of dead space of the gas preparation/delivery system and with a significant contribution arising from the use of the particle filter. The weighing balance technique was identified as an appropriate technique for estimation of gas concentrations. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. [Measurement and estimation methods and research progress of snow evaporation in forests].

    PubMed

    Li, Hui-Dong; Guan, De-Xin; Jin, Chang-Jie; Wang, An-Zhi; Yuan, Feng-Hui; Wu, Jia-Bing

    2013-12-01

    Accurate measurement and estimation of snow evaporation (sublimation) in forests is one of the important issues to the understanding of snow surface energy and water balance, and it is also an essential part of regional hydrological and climate models. This paper summarized the measurement and estimation methods of snow evaporation in forests, and made a comprehensive applicability evaluation, including mass-balance methods (snow water equivalent method, comparative measurements of snowfall and through-snowfall, snow evaporation pan, lysimeter, weighing of cut tree, weighing interception on crown, and gamma-ray attenuation technique) and micrometeorological methods (Bowen-ratio energy-balance method, Penman combination equation, aerodynamics method, surface temperature technique and eddy covariance method). Also this paper reviewed the progress of snow evaporation in different forests and its influencal factors. At last, combining the deficiency of past research, an outlook for snow evaporation rearch in forests was presented, hoping to provide a reference for related research in the future.

  11. Amorphous silicon balanced photodiode for microfluidic applications

    NASA Astrophysics Data System (ADS)

    Caputo, Domenico; de Cesare, Giampiero; Nascetti, Augusto; Scipinotti, Riccardo

    2013-05-01

    In this paper, we present the first integration of an amorphous silicon balanced photosensor with a microfluidic network to perform on-chip detection for biomedical applications, where rejection of large background light intensity is needed. This solution allows to achieve high resolution readout without the need of high dynamic range electronics. The balanced photodiode is constituted by two series-connected a-Si:H/a-SiC:H n-i-p stacked junctions, deposited on a glass substrate. The structure is a three terminal device where two electrodes bias the two diodes in reverse conditions while the third electrode (i.e. the connection point of the two diodes) provides the output signal given by the differential current. The microfluidic network is composed of two channels made in PolyDimetilSiloxane (PDMS) positioned over the glass substrate on the photodiode-side aligning each channel with a diode. This configuration guarantees an optimal optical coupling between luminescence events occurring in the channels and the photosensors. The experiments have been carried out measuring the differential current in identical and different conditions for the two channels. We have found that: the measurement dynamic range can be increased by at least an order of magnitude with respect to conventional photodiodes; the balanced photodiode is able to detect the presence or absence of water in the channel; the presence of fluorescent molecules in the channel can be successful detected by our device without any need of optical filter for the excitation light. These preliminary results demonstrate the successful integration of a microfluidic network with a-Si:H photosensor for on-chip detection in biomedical applications.

  12. Measuring liquid density using Archimedes' principle

    NASA Astrophysics Data System (ADS)

    Hughes, Stephen W.

    2006-09-01

    A simple technique is described for measuring absolute and relative liquid density based on Archimedes' principle. The technique involves placing a container of the liquid under test on an electronic balance and suspending a probe (e.g. a glass marble) attached to a length of line beneath the surface of the liquid. If the volume of the probe is known, the density of liquid is given by the difference between the balance reading before and after immersion of the probe divided by the volume of the probe. A test showed that the density of water at room temperature could be measured to an accuracy and precision of 0.01 ± 0.1%. The probe technique was also used to measure the relative density of milk, Coca-Cola, fruit juice, olive oil and vinegar.

  13. Correcting Severe Varus Deformity Using Trial Components During Total Knee Arthroplasty.

    PubMed

    Kim, Man S; Koh, In J; Choi, Young J; Kim, Yong D; In, Yong

    2017-05-01

    Extensive medial soft tissue release may be necessary to correct severe varus deformity during total knee arthroplasty (TKA). However, this procedure may result in instability. Here, we describe a novel soft tissue balancing technique, which can minimize medial release in severe varus deformity during TKA. Fifty knees (40 patients) with hip-knee-ankle angle of more than 20° of varus were corrected using this technique (group 1). After achieving flexion gap balancing by needle puncturing and spreading of the superficial medial collateral ligament, extension gap balancing was obtained by gradual extension with the trial components in place. After group 1 was set, a one-to-one patient-matched control group who had mild varus deformity was selected by propensity score matching (50 knees, 48 patients, group 2). At postoperative 1 year, mediolateral laxity was compared between the 2 groups using the stress radiographs. Clinical outcomes were also compared using the Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index score. There were no differences in mean medial and lateral laxities between groups 1 and 2 at 1 year after the operation (medial laxity: 2.3° ± 1.4° and 2.7° ± 1.3°, respectively, P = .310) (lateral laxity: 3.6° ± 1.7° and 3.2° ± 2.0°, respectively, P = .459). There were no significant differences in postoperative clinical scores and knee alignment. Our technique of obtaining extension gap balancing using trial components led to safe and effective balancing by avoiding unnecessary extensive release in severe varus deformity during TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Self-balanced real-time photonic scheme for ultrafast random number generation

    NASA Astrophysics Data System (ADS)

    Li, Pu; Guo, Ya; Guo, Yanqiang; Fan, Yuanlong; Guo, Xiaomin; Liu, Xianglian; Shore, K. Alan; Dubrova, Elena; Xu, Bingjie; Wang, Yuncai; Wang, Anbang

    2018-06-01

    We propose a real-time self-balanced photonic method for extracting ultrafast random numbers from broadband randomness sources. In place of electronic analog-to-digital converters (ADCs), the balanced photo-detection technology is used to directly quantize optically sampled chaotic pulses into a continuous random number stream. Benefitting from ultrafast photo-detection, our method can efficiently eliminate the generation rate bottleneck from electronic ADCs which are required in nearly all the available fast physical random number generators. A proof-of-principle experiment demonstrates that using our approach 10 Gb/s real-time and statistically unbiased random numbers are successfully extracted from a bandwidth-enhanced chaotic source. The generation rate achieved experimentally here is being limited by the bandwidth of the chaotic source. The method described has the potential to attain a real-time rate of 100 Gb/s.

  15. Moving forward in fall prevention: an intervention to improve balance among patients in a quasi-experimental study of hospitalized patients.

    PubMed

    Villafañe, Jorge H; Pirali, Caterina; Buraschi, Riccardo; Arienti, Chiara; Corbellini, Camilo; Negrini, Stefano

    2015-12-01

    We investigated the effectiveness of three different rehabilitative programs: group exercise, individual core stability or balance training intervention with a stabilometric platform to improve balance ability in elderly hospitalized patients. We used a prospective quasi-experimental study design. Twenty-eight patients, 39.3% women [age (mean±SD) 72.4±6.5 years], known to have had at least a fall in the last 12 months, were consecutively assigned to one of the following three groups: group exercise intervention, individual core stability or balance training with a stabilometric platform (five sessions a week for 3 weeks in each group). Outcomes were collected at baseline and immediately following the intervention period. In each intervention group, patients showed improvement in balance and mobility, shown as an improvement in the three functional tests score (the Tinetti scale, the Berg Balance Scale, and the Time Up and Go test) (all, P<0.05), whereas, generally, the changes in the score of the test of the stabilometric platform (Postural Stability Test and Fall Risk Test) were not significant for all the interventions. No significant group-by-time interaction was detected for any of the intervention groups, which suggests that the groups improved in the same way. These findings indicate that participation in an exercise program can improve balance and functional mobility, which might contribute toward the reductions of the falls of elderly hospitalized patients and the subsequent fall-related costs. Functional scales might be more appropriate than an instrumental test (Postural Stability Test and Fall Risk Test of the Biodex Balance System) in detecting the functional improvement because of a rehabilitative intervention.

  16. Dispersive detection of radio-frequency-dressed states

    NASA Astrophysics Data System (ADS)

    Jammi, Sindhu; Pyragius, Tadas; Bason, Mark G.; Florez, Hans Marin; Fernholz, Thomas

    2018-04-01

    We introduce a method to dispersively detect alkali-metal atoms in radio-frequency-dressed states. In particular, we use dressed detection to measure populations and population differences of atoms prepared in their clock states. Linear birefringence of the atomic medium enables atom number detection via polarization homodyning, a form of common path interferometry. In order to achieve low technical noise levels, we perform optical sideband detection after adiabatic transformation of bare states into dressed states. The balanced homodyne signal then oscillates independently of field fluctuations at twice the dressing frequency, thus allowing for robust, phase-locked detection that circumvents low-frequency noise. Using probe pulses of two optical frequencies, we can detect both clock states simultaneously and obtain population difference as well as the total atom number. The scheme also allows for difference measurements by direct subtraction of the homodyne signals at the balanced detector, which should technically enable quantum noise limited measurements with prospects for the preparation of spin squeezed states. The method extends to other Zeeman sublevels and can be employed in a range of atomic clock schemes, atom interferometers, and other experiments using dressed atoms.

  17. Performance of the Bowen ratio systems on a 22 deg slope

    NASA Technical Reports Server (NTRS)

    Nie, D.; Flitcroft, I.; Kanemasu, E. T.

    1990-01-01

    The Bowen ratio energy balance technique was used to assess the energy fluxes on inclined surfaces during the First ISLSCP Field Experiment (FIFE). Since air flow over sloping surface may differ from that over flat terrain, it is important to examine whether Bowen ratio measurements taken on sloping surfaces are valid. In this study, the suitability of using the Bowen ratio technique on sloping surfaces was tested by examining the assumptions that the technique requires for valid measurements. This was accomplished by studying the variation of Bowen ratio measurements along a selected slope at the FIFE site. In September 1988, four Bowen ratio systems were set up in a line along the 22 degree north-facing slope with northerly air flow (wind went up the slope). In July of 1989, six Bowen ratio systems were similarly installed with southerly air flow (the wind went down slope). Results indicated that, at distances between 10 to 40 meters from the top of the slope, no temperature or vapor pressure gradient parallel to the slope was detected. Uniform Bowen ratio values were obtained on the slope, and thus the sensible or latent heat flux should be similar along the slope. This indicates that the assumptions for valid flux measurements are reasonably met at the slope. The Bowen ratio technique should give the best estimates of the energy fluxes on slopes similar to that in this study.

  18. Recent Changes in Ices Mass Balance of the Amundsen Sea Sector

    NASA Astrophysics Data System (ADS)

    Sutterley, T. C.; Velicogna, I.; Rignot, E. J.; Mouginot, J.; Flament, T.; van den Broeke, M. R.; van Wessem, M.; Reijmer, C.

    2014-12-01

    The glaciers flowing into the Amundsen Sea Embayment (ASE) sector of West Antarctica were confirmed in the Ice Sheet Mass Balance Inter-comparison Exercise (IMBIE) to be the dominant contributors to the current Antarctic ice mass loss, and recently recognized to be undergoing marine ice sheet instability. Here, we investigate their regional ice mass balance using a time series of satellite and airborne data combined with model output products from the Regional Atmospheric and Climate Model (RACMO). Our dataset includes laser altimetry from NASA's ICESat-1 satellite mission and from Operation IceBridge (OIB) airborne surveys, satellite radar altimetry data from ESA's Envisat mission, time-variable gravity data from NASA/DLR's GRACE mission, surface mass balance products from RACMO, ice velocity from a combination of international synthetic aperture radar satellites and ice thickness data from OIB. We find a record of ice mass balance for the ASE where all the analyzed techniques agree remarkably in magnitude and temporal variability. The mass loss of the region has been increasing continuously since 1992, with no indication of a slow down. The mass loss during the common period averaged 91 Gt/yr and accelerated 20 Gt/yr2. In 1992-2013, the ASE contributed 4.5 mm global sea level rise. Overall, our results demonstrate the synergy of multiple analysis techniques for examining Antarctic Ice Sheet mass balance at the regional scale. This work was performed at UCI and JPL under a contract with NASA.

  19. Bayes classifiers for imbalanced traffic accidents datasets.

    PubMed

    Mujalli, Randa Oqab; López, Griselda; Garach, Laura

    2016-03-01

    Traffic accidents data sets are usually imbalanced, where the number of instances classified under the killed or severe injuries class (minority) is much lower than those classified under the slight injuries class (majority). This, however, supposes a challenging problem for classification algorithms and may cause obtaining a model that well cover the slight injuries instances whereas the killed or severe injuries instances are misclassified frequently. Based on traffic accidents data collected on urban and suburban roads in Jordan for three years (2009-2011); three different data balancing techniques were used: under-sampling which removes some instances of the majority class, oversampling which creates new instances of the minority class and a mix technique that combines both. In addition, different Bayes classifiers were compared for the different imbalanced and balanced data sets: Averaged One-Dependence Estimators, Weightily Average One-Dependence Estimators, and Bayesian networks in order to identify factors that affect the severity of an accident. The results indicated that using the balanced data sets, especially those created using oversampling techniques, with Bayesian networks improved classifying a traffic accident according to its severity and reduced the misclassification of killed and severe injuries instances. On the other hand, the following variables were found to contribute to the occurrence of a killed causality or a severe injury in a traffic accident: number of vehicles involved, accident pattern, number of directions, accident type, lighting, surface condition, and speed limit. This work, to the knowledge of the authors, is the first that aims at analyzing historical data records for traffic accidents occurring in Jordan and the first to apply balancing techniques to analyze injury severity of traffic accidents. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Extensive characterization of human tear fluid collected using different techniques unravels the presence of novel lipid amphiphiles1[S

    PubMed Central

    Lam, Sin Man; Tong, Louis; Duan, Xinrui; Petznick, Andrea; Wenk, Markus R.; Shui, Guanghou

    2014-01-01

    The tear film covers the anterior eye and the precise balance of its various constituting components is critical for maintaining ocular health. The composition of the tear film amphiphilic lipid sublayer, in particular, has largely remained a matter of contention due to the limiting concentrations of these lipid amphiphiles in tears that render their detection and accurate quantitation tedious. Using systematic and sensitive lipidomic approaches, we validated different tear collection techniques and report the most comprehensive human tear lipidome to date; comprising more than 600 lipid species from 17 major lipid classes. Our study confers novel insights to the compositional details of the existent tear film model, in particular the disputable amphiphilic lipid sublayer constituents, by demonstrating the presence of cholesteryl sulfate, O-acyl-ω-hydroxyfatty acids, and various sphingolipids and phospholipids in tears. The discovery and quantitation of the relative abundance of various tear lipid amphiphiles reported herein are expected to have a profound impact on the current understanding of the existent human tear film model. PMID:24287120

  1. Fluid balance within the canine anterolateral compartment and its relationship to compartment syndromes.

    PubMed

    Hargens, A R; Akeson, W H; Mubarak, S J; Owen, C A; Evans, K L; Garetto, L P; Gonsalves, M R; Schmidt, D A

    1978-06-01

    Fluid homeostasis within muscle compartments is maintained by four pressures: capillary blood pressure, capillary blood oncotic pressure, tissue-fluid pressure, and tissue fluid oncotic pressure. As determined in the canine anterolateral compartment, capillary blood pressure is 25 +/- 3 millimeters of mercury; capillary blood oncotic pressure, 26 +/- 3 millimeters of mercury, tissue-pbessure, -2 +/- 2 millimeters of mercury; and tissue-fluid oncotic pressure, 11 +/- 1 millimeters of mercury. The wick technique allows direct measurement of tissue-fluid pressure in skeletal muscle and, with minor modifications, is adapted to collect microsamples of interstitial fluid for determinations of tissue-fluid oncotic pressure. The wick technique detects very slight fluctuations in intracompartmental pressure such as light finger compression, injection of small volumes of fluid, and even pulsation due to adjacent arterial pressure. Adjacent muscle compartments may contain different tissue-fluid pressure due to impermeable osseofascial barriers. Our results obtained in canine muscle compartments pressurized by infusion of autologous plasma suggest that risks of muscle damage are significant at intracompartmental pressures greater than thirty millimeters of mercury.

  2. Walk-based measure of balance in signed networks: Detecting lack of balance in social networks

    NASA Astrophysics Data System (ADS)

    Estrada, Ernesto; Benzi, Michele

    2014-10-01

    There is a longstanding belief that in social networks with simultaneous friendly and hostile interactions (signed networks) there is a general tendency to a global balance. Balance represents a state of the network with a lack of contentious situations. Here we introduce a method to quantify the degree of balance of any signed (social) network. It accounts for the contribution of all signed cycles in the network and gives, in agreement with empirical evidence, more weight to the shorter cycles than to the longer ones. We found that, contrary to what is generally believed, many signed social networks, in particular very large directed online social networks, are in general very poorly balanced. We also show that unbalanced states can be changed by tuning the weights of the social interactions among the agents in the network.

  3. Teaching Children To Love: 80 Games & Fun Activities for Raising Balanced Children in Unbalanced Times.

    ERIC Educational Resources Information Center

    Childre, Doc Lew; Paddison, Sara Hatch, Ed.

    Raising children in today's fast-paced society requires love and technique. Ways that parents can teach children to love, teach them values, and help them balance their lives are discussed in this activity book. The text opens with a discussion of heart intelligence (what is sometimes equated with emotional intelligence). Heart intelligence…

  4. Comparative impacts of Tai Chi, balance training, and a specially-designed yoga program on balance in older fallers.

    PubMed

    Ni, Meng; Mooney, Kiersten; Richards, Luca; Balachandran, Anoop; Sun, Mingwei; Harriell, Kysha; Potiaumpai, Melanie; Signorile, Joseph F

    2014-09-01

    To compare the effect of a custom-designed yoga program with 2 other balance training programs. Randomized controlled trial. Research laboratory. A group of older adults (N=39; mean age, 74.15 ± 6.99 y) with a history of falling. Three different exercise interventions (Tai Chi, standard balance training, yoga) were given for 12 weeks. Balance performance was examined during pre- and posttest using field tests, including the 8-foot up-and-go test, 1-leg stance, functional reach, and usual and maximal walking speed. The static and dynamic balances were also assessed by postural sway and dynamic posturography, respectively. Training produced significant improvements in all field tests (P<.005), but group difference and time × group interaction were not detected. For postural sway, significant decreases in the area of the center of pressure with eyes open (P=.001) and eyes closed (P=.002) were detected after training. For eyes open, maximum medial-lateral velocity significantly decreased for the sample (P=.013). For eyes closed, medial-lateral displacement decreased for Tai Chi (P<.01). For dynamic posturography, significant improvements in overall score (P=.001), time on the test (P=.006), and 2 linear measures in lateral (P=.001) and anterior-posterior (P<.001) directions were seen for the sample. Yoga was as effective as Tai Chi and standard balance training for improving postural stability and may offer an alternative to more traditional programs. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Effects of orthopedic insoles on static balance of older adults wearing thick socks.

    PubMed

    Ma, Christina Zong-Hao; Wong, Duo Wai-Chi; Wan, Anson Hong-Ping; Lee, Winson Chiu-Chun

    2018-06-01

    The wearing of socks and insoles may affect the ability of the foot to detect tactile input influencing postural balance. The aim of this study was to investigate whether (1) thick socks adversely affected the elderly postural balance and (2) orthopedic insoles could improve the elderly postural balance while wearing thick socks. Repeated-measures study design. In total, 14 healthy older adults were recruited. A monofilament test was conducted to evaluate foot plantar sensation with and without thick socks. Subjects then performed the Romberg tests under three conditions: (1) barefoot, (2) with socks only, and (3) with both socks and insoles. Postural balance was assessed by measuring the center of pressure movement during standing in each experimental condition. Thick socks significantly decreased the monofilament score ( p < 0.001), suggesting reduction in ability to detect external forces. All center of pressure parameters increased significantly while wearing thick socks ( p < 0.017), implying reduction of postural stability. They then decreased significantly with the additional use of insoles ( p < 0.017). Previous studies have documented the changes in plantar pressure distribution with the use of orthopedic insoles. This study further suggests that such changes in contact mechanics could produce some balance-improving effects, which appears not to have been reported earlier. Clinical relevance Wearing thick socks reduces plantar pressure sensitivity and increases postural sway which may increase risk of falls. Orthopedic insoles and footwear with similar design could potentially be a cost-effective method in maintaining postural balance when wearing thick socks.

  6. West Antarctic Balance Fluxes: Impact of Smoothing, Algorithm and Topography.

    NASA Astrophysics Data System (ADS)

    Le Brocq, A.; Payne, A. J.; Siegert, M. J.; Bamber, J. L.

    2004-12-01

    Grid-based calculations of balance flux and velocity have been widely used to understand the large-scale dynamics of ice masses and as indicators of their state of balance. This research investigates a number of issues relating to their calculation for the West Antarctic Ice Sheet (see below for further details): 1) different topography smoothing techniques; 2) different grid based flow-apportioning algorithms; 3) the source of the flow direction, whether from smoothed topography, or smoothed gravitational driving stress; 4) different flux routing techniques and 5) the impact of different topographic datasets. The different algorithms described below lead to significant differences in both ice stream margins and values of fluxes within them. This encourages caution in the use of grid-based balance flux/velocity distributions and values, especially when considering the state of balance of individual ice streams. 1) Most previous calculations have used the same numerical scheme (Budd and Warner, 1996) applied to a smoothed topography in order to incorporate the longitudinal stresses that smooth ice flow. There are two options to consider when smoothing the topography, the size of the averaging filter and the shape of the averaging function. However, this is not a physically-based approach to incorporating smoothed ice flow and also introduces significant flow artefacts when using a variable weighting function. 2) Different algorithms to apportion flow are investigated; using 4 or 8 neighbours, and apportioning flow to all down-slope cells or only 2 (based on derived flow direction). 3) A theoretically more acceptable approach of incorporating smoothed ice flow is to use the smoothed gravitational driving stress in x and y components to derive a flow direction. The flux can then be apportioned using the flow direction approach used above. 4) The original scheme (Budd and Warner, 1996) uses an elevation sort technique to calculate the balance flux contribution from all cells to each individual cell. However, elevation sort is only successful when ice cannot flow uphill. Other possible techniques include using a recursive call for each neighbour or using a sparse matrix solution. 5) Two digital elevation models are used as input data, which have significant differences in coastal and mountainous areas and therefore lead to different calculations. Of particular interest is the difference in the Rutford Ice Stream/Carlson Inlet and Kamb Ice Stream (Ice Stream C) fluxes.

  7. [Technical questions of the transrectal specimen extraction].

    PubMed

    Lukovich, Péter; Csibi, Noémi; Bokor, Attila

    2016-03-01

    During laparoscopic partial colectomy the specimen can be extracted transrectally. This technique decreases the invasiveness of the surgery, because the abdominal wall incision is avoided. Premises of a new surgical technique are precise technical description as well as a favourable balance of advantages and disadvantages. In this paper the authors review the technique they apply and analyse their first results. 45 laparoscopic bowel resections were performed by a multidisciplinary team between 16th April 2014 and 1st November 2015. Indication of surgery was endometriosis, and the specimen was extracted transrectally in 11 patients. Having ligated both bowel ends proximal and distal to the section infiltrated with endometriosis, and the proximal bowel secured with a laparoscopic bulldog. Then the bowel was resected and the specimen was extracted in a camera bag transrectally. A purse-string suture was placed into the proximal bowel end, and the anvil of the circular stapler--which was introduced transrectally--was inserted into the bowel. After closing the rectal stump, the anastomosis was performed with a circular stapler. We used this technique when the upper third of the rectum or sigmoid colon was infiltrated with endometriosis. The difference between the operation time of the two techniques (transabdominal vs. transrectal specimen extraction: 108 min vs. 118 min) was not significant. There was not difference in the WBC count between the first and second postoperative day, and there was not any anastomosis leakage detected either. By using the above technique, postoperative infections could have been reduced to minimum. Transrectal specimen extraction did not increase postoperative complication The authors believe this is a safe way of specimen extraction after partial colectomy.

  8. Breath carbon stable isotope ratios identify changes in energy balance and substrate utilization in humans

    USDA-ARS?s Scientific Manuscript database

    Rapid detection of shifts in substrate utilization and energy balance would provide a compelling biofeedback tool to enable individuals to lose weight. In a pilot study, we tested whether the natural abundance of exhaled carbon stable isotope ratios (breath d13C values) reflects shifts between negat...

  9. Working Sandwich Generation Women Utilize Strategies within and between Roles to Achieve Role Balance

    PubMed Central

    Girdler, Sonya J.

    2016-01-01

    Increasingly, women simultaneously balance the roles of mother, parental carer and worker. However, individual role balance strategies among these working ‘sandwich’ generation women have not been thoroughly explored. Eighteen women combining these three roles were interviewed about their individual role balance strategies. Findings were identified through the framework analysis technique, underpinned by the Model of Juggling Occupations. Achieving and maintaining role balance was explained as a complex process accomplished through a range of strategies. Findings revealed the women used six within-role balance strategies: living with integrity, being the best you can, doing what you love, loving what you do, remembering why and searching for signs of success. The women also described six between-role balance strategies: maintaining health and wellbeing, repressing perfectionism, managing time and energy, releasing responsibility, nurturing social connection and reciprocating. These findings provide a basis for health care providers to understand and potentially support working ‘sandwich’ generation women. PMID:27305074

  10. Detection of cancerous cervical cells using physical adhesion of fluorescent silica particles and centripetal force

    PubMed Central

    Gaikwad, Ravi M.; Dokukin, Maxim E.; Iyer, K. Swaminathan; Woodworth, Craig D.; Volkov, Dmytro O.; Sokolov, Igor

    2012-01-01

    Here we describe a non-traditional method to identify cancerous human cervical epithelial cells in a culture dish based on physical interaction between silica beads and cells. It is a simple optical fluorescence-based technique which detects the relative difference in the amount of fluorescent silica beads physically adherent to surfaces of cancerous and normal cervical cells. The method utilizes the centripetal force gradient that occurs in a rotating culture dish. Due to the variation in the balance between adhesion and centripetal forces, cancerous and normal cells demonstrate clearly distinctive distributions of the fluorescent particles adherent to the cell surface over the culture dish. The method demonstrates higher adhesion of silica particles to normal cells compared to cancerous cells. The difference in adhesion was initially observed by atomic force microscopy (AFM). The AFM data were used to design the parameters of the rotational dish experiment. The optical method that we describe is much faster and technically simpler than AFM. This work provides proof of the concept that physical interactions can be used to accurately discriminate normal and cancer cells. PMID:21305062

  11. Effects of static and dynamic higher-order optical modes in balanced homodyne readout for future gravitational waves detectors

    NASA Astrophysics Data System (ADS)

    Zhang, Teng; Danilishin, Stefan L.; Steinlechner, Sebastian; Barr, Bryan W.; Bell, Angus S.; Dupej, Peter; Gräf, Christian; Hennig, Jan-Simon; Houston, E. Alasdair; Huttner, Sabina H.; Leavey, Sean S.; Pascucci, Daniela; Sorazu, Borja; Spencer, Andrew; Wright, Jennifer; Strain, Kenneth A.; Hild, Stefan

    2017-03-01

    With the recent detection of gravitational waves (GWs), marking the start of the new field of GW astronomy, the push for building more sensitive laser-interferometric gravitational wave detectors (GWDs) has never been stronger. Balanced homodyne detection (BHD) allows for a quantum-noise (QN) limited readout of arbitrary light field quadratures, and has therefore been suggested as a vital building block for upgrades to Advanced LIGO and third-generation observatories. In terms of the practical implementation of BHD, we develop a full framework for analyzing the static optical high-order modes (HOMs) occurring in the BHD paths related to the misalignment or mode matching at the input and output ports of the laser interferometer. We find the effects of HOMs on the quantum-noise limited sensitivity is independent of the actual interferometer configuration; e.g. Michelson and Sagnac interferometers are affected in the same way. We show that misalignment of the output ports of the interferometer (output misalignment) only affects the high-frequency part of the quantum-noise limited sensitivity (detection noise). However, at low frequencies, HOMs reduce the interferometer response and the radiation pressure noise (back-action noise) by the same amount and hence the quantum-noise limited sensitivity is not negatively affected in that frequency range. We show that the misalignment of the laser into the interferometer (input misalignment) produces the same effect as output misalignment and additionally decreases the power inside the interferometer. We also analyze dynamic HOM effects, such as beam jitter created by the suspended mirrors of the BHD. Our analyses can be directly applied to any BHD implementation in a future GWD. Moreover, we apply our analytical techniques to the example of the speed meter proof-of-concept experiment under construction in Glasgow. We find that for our experimental parameters, the performance of our seismic isolation system in the BHD paths is compatible with the design sensitivity of the experiment.

  12. A 1 kg Mass Comparator Using Flexure-Strip Suspensions: Preliminary Results

    NASA Astrophysics Data System (ADS)

    Quinn, T. J.; Speake, C. C.; Davis, R. S.

    1986-01-01

    This paper describes the design and construction of a novel form of equal-arm balance. The balance has been designed to study the performance of flexure strips for use as pivots in a 1 kg mass comparator working at the highest accuracy. The beam of the balance is servo controlled using optical detection of angular position and electromagnetic control. Small mass differences are measured in terms of the differences in the servo currents required to reproduce the same position of the beam. Preliminary results using this prototype balance indicate that an accuracy in mass comparison of about 5 parts in 1010 can be achieved.

  13. Propensity Score Techniques and the Assessment of Measured Covariate Balance to Test Causal Associations in Psychological Research

    ERIC Educational Resources Information Center

    Harder, Valerie S.; Stuart, Elizabeth A.; Anthony, James C.

    2010-01-01

    There is considerable interest in using propensity score (PS) statistical techniques to address questions of causal inference in psychological research. Many PS techniques exist, yet few guidelines are available to aid applied researchers in their understanding, use, and evaluation. In this study, the authors give an overview of available…

  14. Hair segmentation using adaptive threshold from edge and branch length measures.

    PubMed

    Lee, Ian; Du, Xian; Anthony, Brian

    2017-10-01

    Non-invasive imaging techniques allow the monitoring of skin structure and diagnosis of skin diseases in clinical applications. However, hair in skin images hampers the imaging and classification of the skin structure of interest. Although many hair segmentation methods have been proposed for digital hair removal, a major challenge in hair segmentation remains in detecting hairs that are thin, overlapping, of similar contrast or color to underlying skin, or overlaid on highly-textured skin structure. To solve the problem, we present an automatic hair segmentation method that uses edge density (ED) and mean branch length (MBL) to measure hair. First, hair is detected by the integration of top-hat transform and modified second-order Gaussian filter. Second, we employ a robust adaptive threshold of ED and MBL to generate a hair mask. Third, the hair mask is refined by k-NN classification of hair and skin pixels. The proposed algorithm was tested using two datasets of healthy skin images and lesion images respectively. These datasets were taken from different imaging platforms in various illumination levels and varying skin colors. We compared the hair detection and segmentation results from our algorithm and six other hair segmentation methods of state of the art. Our method exhibits high value of sensitivity: 75% and specificity: 95%, which indicates significantly higher accuracy and better balance between true positive and false positive detection than the other methods. Published by Elsevier Ltd.

  15. Comparison of Clean-Up Methods for Ochratoxin A on Wine, Beer, Roasted Coffee and Chili Commercialized in Italy

    PubMed Central

    Prelle, Ambra; Spadaro, Davide; Denca, Aleksandra; Garibaldi, Angelo; Gullino, Maria Lodovica

    2013-01-01

    The most common technique used to detect ochratoxin A (OTA) in food matrices is based on extraction, clean-up, and chromatography detection. Different clean-up cartridges, such as immunoaffinity columns (IAC), molecular imprinting polymers (MIP), Mycosep™ 229, Mycospin™, and Oasis® HLB (Hydrophilic Lipophilic balance) as solid phase extraction were tested to optimize the purification for red wine, beer, roasted coffee and chili. Recovery, reproducibility, reproducibility, limit of detection (LOD) and limit of quantification (LOQ) were calculated for each clean-up method. IAC demonstrated to be suitable for OTA analysis in wine and beer with recovery rate >90%, as well as Mycosep™ for wine and chili. On the contrary, MIP columns were the most appropriate to clean up coffee. A total of 120 samples (30 wines, 30 beers, 30 roasted coffee, 30 chili) marketed in Italy were analyzed, by applying the developed clean-up methods. Twenty-seven out of 120 samples analyzed (22.7%: two wines, five beers, eight coffees, and 12 chili) resulted positive to OTA. A higher incidence of OTA was found in chili (40.0%) more than wine (6.6%), beers (16.6%) and coffee (26.6%). Moreover, OTA concentration in chili was the highest detected, reaching 47.8 µg/kg. Furthermore, three samples (2.5%), two wines and one chili, exceeded the European threshold. PMID:24152987

  16. Automated brain tumour detection and segmentation using superpixel-based extremely randomized trees in FLAIR MRI.

    PubMed

    Soltaninejad, Mohammadreza; Yang, Guang; Lambrou, Tryphon; Allinson, Nigel; Jones, Timothy L; Barrick, Thomas R; Howe, Franklyn A; Ye, Xujiong

    2017-02-01

    We propose a fully automated method for detection and segmentation of the abnormal tissue associated with brain tumour (tumour core and oedema) from Fluid- Attenuated Inversion Recovery (FLAIR) Magnetic Resonance Imaging (MRI). The method is based on superpixel technique and classification of each superpixel. A number of novel image features including intensity-based, Gabor textons, fractal analysis and curvatures are calculated from each superpixel within the entire brain area in FLAIR MRI to ensure a robust classification. Extremely randomized trees (ERT) classifier is compared with support vector machine (SVM) to classify each superpixel into tumour and non-tumour. The proposed method is evaluated on two datasets: (1) Our own clinical dataset: 19 MRI FLAIR images of patients with gliomas of grade II to IV, and (2) BRATS 2012 dataset: 30 FLAIR images with 10 low-grade and 20 high-grade gliomas. The experimental results demonstrate the high detection and segmentation performance of the proposed method using ERT classifier. For our own cohort, the average detection sensitivity, balanced error rate and the Dice overlap measure for the segmented tumour against the ground truth are 89.48 %, 6 % and 0.91, respectively, while, for the BRATS dataset, the corresponding evaluation results are 88.09 %, 6 % and 0.88, respectively. This provides a close match to expert delineation across all grades of glioma, leading to a faster and more reproducible method of brain tumour detection and delineation to aid patient management.

  17. Development of a Theory-Based Intervention to Increase Clinical Measurement of Reactive Balance in Adults at Risk of Falls.

    PubMed

    Sibley, Kathryn M; Brooks, Dina; Gardner, Paula; Janaudis-Ferreira, Tania; McGlynn, Mandy; OʼHoski, Sachi; McEwen, Sara; Salbach, Nancy M; Shaffer, Jennifer; Shing, Paula; Straus, Sharon E; Jaglal, Susan B

    2016-04-01

    Effective balance reactions are essential for avoiding falls, but are not regularly measured by physical therapists. Physical therapists report wanting to improve reactive balance assessment, and theory-based approaches are recommended as the foundation for the development of interventions. This article describes how a behavior change theory for health care providers, the theoretical domains framework (TDF), was used to develop an intervention to increase reactive balance measurement among physical therapists who work in rehabilitation settings and treat adults who are at risk of falls. We employed published recommendations for using the TDF-guided intervention development. We identified what health care provider behavior is in need of change, relevant barriers and facilitators, strategies to address them, and how we would measure behavior change. In this case, identifying strategies required selecting both a reactive balance measure and behavior change techniques. Previous research had determined that physical therapists need to increase reactive balance measurement, and identified barriers and facilitators that corresponded to 8 TDF domains. A published review informed the selection of the Balance Evaluation Systems Test (Reactive Postural Responses Section) as addressing the barriers and facilitators, and existing research informed the selection of 9 established behavior change techniques corresponding to each identified TDF domain. The TDF framework were incorporated into a 12-month intervention with interactive group sessions, local champions, and health record modifications. Intervention effect can be evaluated using health record abstraction, questionnaires, and qualitative semistructured interviews. Although future research will evaluate the intervention in a controlled study, the process of theory-based intervention development can be applied to other rehabilitation research contexts, maximizing the impact of this work.Video Abstract is available for more insights from the authors (see Supplemental Digital Content 1, http://links.lww.com/JNPT/A123).

  18. Application of Temperature Sensitivities During Iterative Strain-Gage Balance Calibration Analysis

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.

    2011-01-01

    A new method is discussed that may be used to correct wind tunnel strain-gage balance load predictions for the influence of residual temperature effects at the location of the strain-gages. The method was designed for the iterative analysis technique that is used in the aerospace testing community to predict balance loads from strain-gage outputs during a wind tunnel test. The new method implicitly applies temperature corrections to the gage outputs during the load iteration process. Therefore, it can use uncorrected gage outputs directly as input for the load calculations. The new method is applied in several steps. First, balance calibration data is analyzed in the usual manner assuming that the balance temperature was kept constant during the calibration. Then, the temperature difference relative to the calibration temperature is introduced as a new independent variable for each strain--gage output. Therefore, sensors must exist near the strain--gages so that the required temperature differences can be measured during the wind tunnel test. In addition, the format of the regression coefficient matrix needs to be extended so that it can support the new independent variables. In the next step, the extended regression coefficient matrix of the original calibration data is modified by using the manufacturer specified temperature sensitivity of each strain--gage as the regression coefficient of the corresponding temperature difference variable. Finally, the modified regression coefficient matrix is converted to a data reduction matrix that the iterative analysis technique needs for the calculation of balance loads. Original calibration data and modified check load data of NASA's MC60D balance are used to illustrate the new method.

  19. Comparison of the effects of virtual reality-based balance exercises and conventional exercises on balance and fall risk in older adults living in nursing homes in Turkey.

    PubMed

    Yeşilyaprak, Sevgi Sevi; Yıldırım, Meriç Şenduran; Tomruk, Murat; Ertekin, Özge; Algun, Z Candan

    2016-01-01

    There is limited information on effective balance training techniques including virtual reality (VR)-based balance exercises in residential settings and no studies have been designed to compare the effects of VR-based balance exercises with conventional balance exercises in older adults living in nursing homes in Turkey. The objective of our study was to investigate the effects of VR-based balance exercises on balance and fall risk in comparison to conventional balance exercises in older adults living in nursing homes. A total sample of 18 subjects (65-82 years of age) with fall history who were randomly assigned to either the VR group (Group 1, n = 7) or the conventional exercise group (Group 2, n = 11) completed the exercise training. In both groups, Berg balance score (BBS), timed up & go duration, and left leg stance and tandem stance duration with eyes closed significantly improved with time (p < 0.05), but changes were similar in both groups (p > 0.05) after training, indicating that neither the exercise method was superior. Similar improvements were found in balance and fall risk with VR-based balance training and conventional balance training in older adults living in the nursing home. Both exercise trainings can be preferable by health care professionals considering fall prevention. Appropriate patient selection is essential.

  20. Innovation in surgical technology and techniques: Challenges and ethical issues.

    PubMed

    Geiger, James D; Hirschl, Ronald B

    2015-06-01

    The pace of medical innovation continues to increase. The deployment of new technologies in surgery creates many ethical challenges including how to determine safety of the technology, what is the timing and process for deployment of a new technology, how are patients informed before undergoing a new technology or technique, how are the outcomes of a new technology evaluated and how are the responsibilities of individual patients and society at large balanced. Ethical considerations relevant to the implementation of ECMO and robotic surgery are explored to further discussion of how we can optimize the delicate balance between innovation and regulation. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Laser balancing system for high material removal rates

    NASA Technical Reports Server (NTRS)

    Jones, M. G.; Georgalas, G.; Ortiz, A. L.

    1984-01-01

    A laser technique to remove material in excess of 10 mg/sec from a spinning rotor is described. This material removal rate is 20 times greater than previously reported for a surface speed of 30 m/sec. Material removal enhancement was achieved by steering a focused laser beam with moving optics to increase the time of laser energy interaction with a particular location on the circumferential surface of a spinning rotor. A neodymium:yttrium aluminum garnet (Nd:YAG) pulse laser was used in this work to evaluate material removal for carbon steel, 347 stainless steel, Inconal 718, and titanium 6-4. This technique is applicable to dynamic laser balancing.

  2. Characterization of flexure hinges for the French watt balance experiment

    NASA Astrophysics Data System (ADS)

    Pinot, Patrick; Genevès, Gérard

    2014-08-01

    In the French watt balance experiment, the translation and rotation functions must have no backlash, no friction, nor the need for lubricants. In addition errors in position and movement must be below 100 nm. Flexure hinges can meet all of these criteria. Different materials, profile shapes and machining techniques have been studied. The flexure pivots have been characterized using three techniques: 1) an optical microscope and, if necessary, a SEM to observe the surface inhomogeneities; 2) a mass comparator to determine the bending stiffness of unloaded pivots; 3) a loaded beam oscillating freely under vacuum to study the dynamic behavior of loaded pivots.

  3. Detection of Acute and Long-Term Effects of Concussion: Dual-Task Gait Balance Control Versus Computerized Neurocognitive Test.

    PubMed

    Howell, David R; Osternig, Louis R; Chou, Li-Shan

    2018-02-16

    To examine the acute (within 72h of injury) and long-term (2mo postinjury) independent associations between objective dual-task gait balance and neurocognitive measurements among adolescents and young adults with a concussion and matched controls. Longitudinal case-control. Motion analysis laboratory. A total of 95 participants completed the study: 51 who sustained a concussion (mean age, 17.5±3.3y; 71% men) and 44 controls (mean age, 17.7±2.9y; 72% men). Participants who sustained a concussion underwent a dual-task gait analysis and computerized neurocognitive testing within 72 hours of injury and again 2 months later. Uninjured controls also completed the same test protocol in similar time increments. Not applicable. We compared dual-task gait balance control and computerized neurocognitive test performance between groups using independent samples t tests. Multivariable binary logistic regression models were then constructed for each testing time to determine the association between group membership (concussion vs control), dual-task gait balance control, and neurocognitive function. Medial-lateral center-of-mass displacement during dual-task gait was independently associated with group membership at the initial test (adjusted odds ratio [aOR], 2.432; 95% confidence interval [CI], 1.269-4.661) and 2-month follow-up test (aOR, 1.817; 95% CI, 1.014-3.256) tests. Visual memory composite scores were significantly associated with group membership at the initial hour postinjury time point (aOR, .953; 95% CI, .833-.998). However, the combination of computerized neurocognitive test variables did not predict dual-task gait balance control for participants with concussion, and no single neurocognitive variable was associated with dual-task gait balance control at either testing time. Dual-task assessments concurrently evaluating gait and cognitive performance may allow for the detection of persistent deficits beyond those detected by computerized neurocognitive deficits alone. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. Association of postural balance and isometric muscle strength in early- and middle-school-age boys.

    PubMed

    Ibrahim, Alaa I; Muaidi, Qassim I; Abdelsalam, Mohammed S; Hawamdeh, Ziad M; Alhusaini, Adel A

    2013-01-01

    The purpose of this study was to evaluate the isometric muscle strength (IMS) and dynamic balance in early- and middle-school-age boys and to assess the strength of association between the dynamic balance scores and 6 different IMS indexes. This is a cross-sectional study of a convenience sample of 94 boys who were 6 to 10 years of age and classified into an early school age (6-8 years) group (n = 50) and a middle school age (8-10 years) group (n = 44). Balance was tested using a Biodex Balance System. Anteroposterior Stability Index, Mediolateral Stability Index, and Overall Stability Index were recorded. IMS of 11 muscle groups was measured with a handheld dynamometer and categorized into 6 different muscle strength indices. The mean (SD) values of anteroposterior, mediolateral, and overall stability indexes observed for all study boys were 1.9 ± 1.0, 1.2 ± 0.7, and 2.5 ± 1.2 respectively. In the middle school age group, strong positive relationships were detected between the overall stability index and trunk, lower limb, anti-gravity, pro-gravity, and total strength indexes (r = -0.86/P < .001, r = -0.91/P < .001, r = -0.88/P < .001, r = -0.83/P < .001, and r = -0.84/P < .001 respectively), while no significant relationship was detected with the upper limb strength index (r = 0.159/P = .303). In the early school age group, moderate positive relationships were detected between the overall stability index and anti-gravity, lower limb, and total strength indexes (r = -0.404/P = .004, r = -0.356/P = .011, and r = -0.350/P = .013 respectively). Dynamic balance did not appear to be mature by the age of 10 years. Better balance skills were recorded in the mediolateral direction than in the anteroposterior direction. In the middle school age group, the overall stability index had positive relationships with almost all examined muscle strength indexes excepting the upper limb strength index. © 2013. Published by National University of Health Sciences All rights reserved.

  5. The balance between the pro-inflammatory effect of plasma noradrenaline and the anti-inflammatory effect of neuronal noradrenaline determines the peripheral effects of noradrenaline.

    PubMed

    Crotty, T P

    2015-11-01

    Experiments on canine lateral saphenous vein segments have shown that noradrenaline causes potent, flow dependent effects, at a threshold concentration comparable to that of plasma noradrenaline, when it stimulates a segment by diffusion from its microcirculation (vasa vasorum). The effects it causes contrast with those neuronal noradrenaline causes in vivo and that, in the light of the principle that all information is transmitted in patterns that need contrast to be detected - star patterns need darkness, sound patterns, quietness - has generated the hypothesis that plasma noradrenaline provides the obligatory contrast tissues need to detect and respond to the regulatory information encrypted in the diffusion pattern of neuronal noradrenaline. Based on the implications of that hypothesis, the controlled variable of the peripheral noradrenergic system is believed to be the maintenance of a set point balance between the contrasting effects of plasma and neuronal noradrenaline on a tissue. The hypothalamic sympathetic centres are believed to monitor that balance through the level of afferent sympathetic traffic they receive from a tissue and to correct any deviation it detects in the balance by adjusting the level of efferent sympathetic input it projects to the tissue. The failure of the centres to maintain the correct balance is believed to be responsible for inflammatory and genetic disorders. When the failure causes the balance to be polarised in favour of the effect of plasma noradrenaline that is believed to cause inflammatory diseases like dilator cardiac failure, renal hypertension, varicose veins and aneurysms; when it causes it to be polarised in favour of the effect of neuronal noradrenaline that is believed to cause genetic diseases like hypertrophic cardiopathy, pulmonary hypertension and stenoses and when, in pregnancy, a factor causes the polarity to favour plasma noradrenaline in all the maternal tissues except the uterus and conceptus, where it favours neuronal noradrenaline, that is believed to cause preeclampsia. Finally, the shift in the balance caused by the slow physiological increase in plasma noradrenaline concentration in life is believed to be responsible for ageing. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Remote Sensing of Cryosphere: Estimation of Mass Balance Change in Himalayan Glaciers

    NASA Astrophysics Data System (ADS)

    Ambinakudige, Shrinidhi; Joshi, Kabindra

    2012-07-01

    Glacial changes are an important indicator of climate change. Our understanding mass balance change in Himalayan glaciers is limited. This study estimates mass balance of some major glaciers in the Sagarmatha National Park (SNP) in Nepal using remote sensing applications. Remote sensing technique to measure mass balance of glaciers is an important methodological advance in the highly rugged Himalayan terrain. This study uses ASTER VNIR, 3N (nadir view) and 3B (backward view) bands to generate Digital Elevation Models (DEMs) for the SNP area for the years 2002, 2003, 2004 and 2005. Glacier boundaries were delineated using combination of boundaries available in the Global land ice measurement (GLIMS) database and various band ratios derived from ASTER images. Elevation differences, glacial area, and ice densities were used to estimate the change in mass balance. The results indicated that the rate of glacier mass balance change was not uniform across glaciers. While there was a decrease in mass balance of some glaciers, some showed increase. This paper discusses how each glacier in the SNP area varied in its annual mass balance measurement during the study period.

  7. Evaluation of Dentin Defect Formation during Retreatment with Hand and Rotary Instruments: A Micro-CT Study.

    PubMed

    Yilmaz, Ayca; Helvacioglu-Yigit, Dilek; Gur, Cansu; Ersev, Handan; Kiziltas Sendur, Gullu; Avcu, Egemen; Baydemir, Canan; Abbott, Paul Vincent

    2017-01-01

    The purpose of this study was to compare the incidence and longitudinal propagation of dentin defects after gutta-percha removal with hand and rotary instruments using microcomputed tomography. Twenty mandibular incisors were prepared using the balanced-force technique and scanned in a 19.9  μ m resolution. Following filling with the lateral compaction technique, gutta-percha was removed with ProTaper Universal Retreatment (PTUR) or hand instruments. After rescanning, a total of 24,120 cross-sectional images were analyzed. The numbers, types, and longitudinal length changes of defects were recorded. Defects were observed in 36.90% of the cross sections. A total of 73 defects were comprised of 87.67% craze lines, 2.73% partial cracks, and 9.58% fractures. No significant difference in terms of new defect formation was detected between the retreatment groups. The apical and middle portions of the roots had more dentin defects than the coronal portions. Defects in three roots of the PTUR instrument group increased in length. Under the conditions of this in vitro study, gutta-percha removal seemed to not increase the incidence of dentin defect formation, but the longitudinal defect propagation finding suggests possible cumulative dentinal damage due to additional endodontic procedures. Hand and rotary instrumentation techniques caused similar dentin defect formation during root canal retreatment.

  8. Vapor pressures of a homologous series of polyethylene glycols as a reference data set for validating vapor pressure measurement techniques.

    NASA Astrophysics Data System (ADS)

    Krieger, Ulrich; Marcolli, Claudia; Siegrist, Franziska

    2015-04-01

    The production of secondary organic aerosol (SOA) by gas-to-particle partitioning is generally represented by an equilibrium partitioning model. A key physical parameter which governs gas-particle partitioning is the pure component vapor pressure, which is difficult to measure for low- and semivolatile compounds. For typical atmospheric compounds like e.g. citric acid or tartaric acid, vapor pressures have been reported in the literature which differ by up to six orders of magnitude [Huisman et al., 2013]. Here, we report vapor pressures of a homologous series of polyethylene glycols (triethylene glycol to octaethylene glycol) determined by measuring the evaporation rate of single, levitated aerosol particles in an electrodynamic balance. We propose to use those as a reference data set for validating different vapor pressure measurement techniques. With each addition of a (O-CH2-CH2)-group the vapor pressure is lowered by about one order of magnitude which makes it easy to detect the lower limit of vapor pressures accessible with a particular technique down to a pressure of 10-8 Pa at room temperature. Reference: Huisman, A. J., Krieger, U. K., Zuend, A., Marcolli, C., and Peter, T., Atmos. Chem. Phys., 13, 6647-6662, 2013.

  9. Stride dynamics, gait variability and prospective falls risk in active community dwelling older women.

    PubMed

    Paterson, Kade; Hill, Keith; Lythgo, Noel

    2011-02-01

    Measures of walking instability such as stride dynamics and gait variability have been shown to identify future fallers in older adult populations with gait limitations or mobility disorders. This study investigated whether measures of walking instability can predict future fallers (over a prospective 12 month period) in a group of healthy and active older women. Ninety-seven healthy active women aged between 55 and 90 years walked for 7 min around a continuous walking circuit. Gait data recorded by a GAITRite(®) walkway and foot-mounted accelerometers were used to calculate measures of stride dynamics and gait variability. The participant's physical function and balance were assessed. Fall incidence was monitored over the following 12 months. Inter-limb differences (p≤0.04) in stride dynamics were found for fallers (one or more falls) aged over 70 years, and multiple fallers (two or more falls) aged over 55 years, but not in non-fallers or a combined group of single and non-fallers. No group differences were found in the measures of physical function, balance or gait, including variability. Additionally, no gait variable predicted falls. Reduced coordination of inter-limb dynamics was found in active healthy older fallers and multiple fallers despite no difference in other measures of intrinsic falls risk. Evaluating inter-limb dynamics may be a clinically sensitive technique to detect early gait instability and falls risk in high functioning older adults, prior to change in other measures of physical function, balance and gait. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. The PARAChute Project: Remote Monitoring of Posture and Gait for Fall Prevention

    NASA Astrophysics Data System (ADS)

    Hewson, David J.; Duchêne, Jacques; Charpillet, François; Saboune, Jamal; Michel-Pellegrino, Valérie; Amoud, Hassan; Doussot, Michel; Paysant, Jean; Boyer, Anne; Hogrel, Jean-Yves

    2007-12-01

    Falls in the elderly are a major public health problem due to both their frequency and their medical and social consequences. In France alone, more than two million people aged over 65 years old fall each year, leading to more than 9 000 deaths, in particular in those over 75 years old (more than 8 000 deaths). This paper describes the PARAChute project, which aims to develop a methodology that will enable the detection of an increased risk of falling in community-dwelling elderly. The methods used for a remote noninvasive assessment for static and dynamic balance assessments and gait analysis are described. The final result of the project has been the development of an algorithm for movement detection during gait and a balance signature extracted from a force plate. A multicentre longitudinal evaluation of balance has commenced in order to validate the methodologies and technologies developed in the project.

  11. Label-Free Detection of Bacillus anthracis Spore Uptake in Macrophage Cells Using Analytical Optical Force Measurements.

    PubMed

    Hebert, Colin G; Hart, Sean; Leski, Tomasz A; Terray, Alex; Lu, Qin

    2017-10-03

    Understanding the interaction between macrophage cells and Bacillus anthracis spores is of significant importance with respect to both anthrax disease progression, spore detection for biodefense, as well as understanding cell clearance in general. While most detection systems rely on specific molecules, such as nucleic acids or proteins and fluorescent labels to identify the target(s) of interest, label-free methods probe changes in intrinsic properties, such as size, refractive index, and morphology, for correlation with a particular biological event. Optical chromatography is a label free technique that uses the balance between optical and fluidic drag forces within a microfluidic channel to determine the optical force on cells or particles. Here we show an increase in the optical force experienced by RAW264.7 macrophage cells upon the uptake of both microparticles and B. anthracis Sterne 34F2 spores. In the case of spores, the exposure was detected in as little as 1 h without the use of antibodies or fluorescent labels of any kind. An increase in the optical force was also seen in macrophage cells treated with cytochalasin D, both with and without a subsequent exposure to spores, indicating that a portion of the increase in the optical force arises independent of phagocytosis. These results demonstrate the capability of optical chromatography to detect subtle biological differences in a rapid and sensitive manner and suggest future potential in a range of applications, including the detection of biological threat agents for biodefense and pathogens for the prevention of sepsis and other diseases.

  12. Leader Development: What the Army Can Learn from Collegiate Coaches While Embracing Doctrine and the Art of Coaching

    DTIC Science & Technology

    2011-12-16

    Balanced Approach ...............................................................................32 Understanding Loyalty...across the board . How do we develop leaders? And can we use techniques developed and utilized by collegiate head coaches to enhance our capability...Mission Command. Described as the balance between the art of command and the science of control. The commander must be able to understand, visualize

  13. Water vapor mass balance method for determining air infiltration rates in houses

    Treesearch

    David R. DeWalle; Gordon M. Heisler

    1980-01-01

    A water vapor mass balance technique that includes the use of common humidity-control equipment can be used to determine average air infiltration rates in buildings. Only measurements of the humidity inside and outside the home, the mass of vapor exchanged by a humidifier/dehumidifier, and the volume of interior air space are needed. This method gives results that...

  14. An Investigation on Balance between Professional and Personal Work of Women Teachers

    ERIC Educational Resources Information Center

    Priya, J. Johnsi

    2017-01-01

    The present study aims to examine the work-life balance of women teachers in Chennai city. In this normative survey study, 100 women teachers were selected as sample by using convenient sampling technique. The data were collected from 100 women teachers who are working in eight Higher Secondary Schools at chennai city using the Work-life Balance…

  15. First International Symposium on Strain Gauge Balances. Pt. 1

    NASA Technical Reports Server (NTRS)

    Tripp, John S. (Editor); Tcheng, Ping (Editor)

    1999-01-01

    The first International Symposium on Strain Gauge Balances was sponsored and held at NASA Langley Research Center during October 22-25, 1996. The symposium provided an open international forum for presentation, discussion, and exchange of technical information among wind tunnel test technique specialists and strain gauge balance designers. The Symposium also served to initiate organized professional activities among the participating and relevant international technical communities. Over 130 delegates from 15 countries were in attendance. The program opened with a panel discussion, followed by technical paper sessions, and guided tours of the National Transonic Facility (NTF) wind tunnel, a local commercial balance fabrication facility, and the LaRC balance calibration laboratory. The opening panel discussion addressed "Future Trends in Balance Development and Applications." Forty-six technical papers were presented in 11 technical sessions covering the following areas: calibration, automatic calibration, data reduction, facility reports, design, accuracy and uncertainty analysis, strain gauges, instrumentation, balance design, thermal effects, finite element analysis, applications, and special balances. At the conclusion of the Symposium, a steering committee representing most of the nations and several U.S. organizations attending the Symposium was established to initiate planning for a second international balance symposium, to be held in 1999 in the UK.

  16. First International Symposium on Strain Gauge Balances. Part 2

    NASA Technical Reports Server (NTRS)

    Tripp, John S (Editor); Tcheng, Ping (Editor)

    1999-01-01

    The first International Symposium on Strain Gauge Balances was sponsored and held at NASA Langley Research Center during October 22-25, 1996. The symposium provided an open international forum for presentation, discussion, and exchange of technical information among wind tunnel test technique specialists and strain gauge balance designers. The Symposium also served to initiate organized professional activities among the participating and relevant international technical communities. Over 130 delegates from 15 countries were in attendance. The program opened with a panel discussion, followed by technical paper sessions, and guided tours of the National Transonic Facility (NTF) wind tunnel, a local commercial balance fabrication facility, and the LaRC balance calibration laboratory. The opening panel discussion addressed "Future Trends in Balance Development and Applications." Forty-six technical papers were presented in 11 technical sessions covering the following areas: calibration, automatic calibration, data reduction, facility reports, design, accuracy and uncertainty analysis, strain gauges, instrumentation, balance design, thermal effects, finite element analysis, applications, and special balances. At the conclusion of the Symposium, a steering committee representing most of the nations and several U.S. organizations attending the Symposium was established to initiate planning for a second international balance symposium, to be held in 1999 in the UK.

  17. Multiband phase-modulated radio over IsOWC link with balanced coherent homodyne detection

    NASA Astrophysics Data System (ADS)

    Zong, Kang; Zhu, Jiang

    2017-11-01

    In this paper, we present a multiband phase-modulated radio over intersatellite optical wireless communication (IsOWC) link with balanced coherent homodyne detection. The proposed system can provide high linearity for transparent transport of multiband radio frequency (RF) signals and better receiver sensitivity than intensity modulated with direct detection (IM/DD) system. The exact analytical expression of signal to noise and distortion ratio (SNDR) is derived considering the third-order intermodulation product and amplifier spontaneous emission (ASE) noise. Numerical results of SNDR with various number of subchannels and modulation index are given. Results indicate that the optimal modulation index exists to maximize the SNDR. With the same system parameters, the value of the optimal modulation index will decrease with the increase of number of subchannels.

  18. A familial {open_quotes}balanced{close_quotes} 3;9 translocation with cryptic 8q insertion leading to deletion and duplication of 9p23 loci in siblings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wagstaff, J.; Hemann, M.

    1994-09-01

    Families in which a balanced translocation has been transmitted from a normal parent to a child with a phenotypic abnormality have been a longstanding puzzle for human geneticists. A child with phenotypic features of the 9p- syndrome, including metopic craniosynostosis, small ears, abdominal wall defect, and mental retardation, was found to have a cytogenetically balanced 3;9 translocation, with breakpoints at 3p11 and 9p23, inherited from his normal father. He also exhibited marked hypopigmentation of hair and skin. Analysis with a cDNA probe from the TYRP1 (tyrosinase-related protein 1) gene in 9p23 showed heterozygous deletion in the child but in neithermore » parent. This submicroscopic deletion also included loci D9S157, D9S274, D9S268, and D9S267. FISH analysis of the proband`s father indicated the 9p23 loci deleted in his son were present on neither the der(3) nor the der(9) translocation product, but had been inserted into the long arm of chromosome 8. Therefore, the apparent deletion of these loci in the proband was the result of meiotic segregation of the father`s 3;9 translocation chromosomes together with his normal chromosome 8. Neither the deletion from the translocation chromosomes nor the insertion into 8q was detectable by standard chromosome banding techniques. The proband`s sister exhibited speech delay, mild facial dysmorphism, and renal malformation, and her karyotype was 46,XX. Molecular analysis of this sister showed 3 copies of 9p23 sequences, indicating that she had inherited normal chromosomes 3 and 9 from her father as well as the chromosome 8 with the insertion from 9p23. This analysis illustrates a new mechanism to explain cases of phenotypic discordance in familial balanced translocations: submicroscopic deletion of material from the translocation breakpoint and insertion into a third chromosome in the balanced parent, with meiotic segregation leading to loss of the inserted material in the child.« less

  19. Revisiting the flocculation kinetics of destabilized asphaltenes.

    PubMed

    Vilas Bôas Fávero, Cláudio; Maqbool, Tabish; Hoepfner, Michael; Haji-Akbari, Nasim; Fogler, H Scott

    2017-06-01

    A comprehensive review of the recently published work on asphaltene destabilization and flocculation kinetics is presented. Four different experimental techniques were used to study asphaltenes undergoing flocculation process in crude oils and model oils. The asphaltenes were destabilized by different n-alkanes and a geometric population balance with the Smoluchowski collision kernel was used to model the asphaltene aggregation process. Additionally, by postulating a relation between the aggregation collision efficiency and the solubility parameter of asphaltenes and the solution, a unified model of asphaltene aggregation model was developed. When the aggregation model is applied to the experimental data obtained from several different crude oil and model oils, the detection time curves collapsed onto a universal single line, indicating that the model successfully captures the underlying physics of the observed process. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Differential extraction of radiocarbon associated with soil biomass and humus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsao, C.W.; Bartha, R.

    To detect the humification of organic compounds in soil that bypasses biomass incorporation, selective extraction procedures for radiocarbon from soil biomass and humus were evaluated. Following the incubation of [sup 14]C-glucose and [sup 14]C-benzoate in soil, fumigation--0.5 M K[sub 2]SO[sub 4] extraction and 0.15 M Na[sub 4]P[sub 2]O[sub 7] extraction selectively removed biomass-associated and humus-associated radiocarbon, respectively. Applying the recovery correction of 3.4[times] to biomass and 3.5[times] to humus, radiocarbon balances of 95 to 107% were obtained during a time window following the degradation of these substrates. Negligible overlap between the extractions renders the technique suitable for investigating the fatemore » of organics that, through cometabolism, attain unusual radiocarbon distributions in soil.« less

  1. Pattern recognition of electronic bit-sequences using a semiconductor mode-locked laser and spatial light modulators

    NASA Astrophysics Data System (ADS)

    Bhooplapur, Sharad; Akbulut, Mehmetkan; Quinlan, Franklyn; Delfyett, Peter J.

    2010-04-01

    A novel scheme for recognition of electronic bit-sequences is demonstrated. Two electronic bit-sequences that are to be compared are each mapped to a unique code from a set of Walsh-Hadamard codes. The codes are then encoded in parallel on the spectral phase of the frequency comb lines from a frequency-stabilized mode-locked semiconductor laser. Phase encoding is achieved by using two independent spatial light modulators based on liquid crystal arrays. Encoded pulses are compared using interferometric pulse detection and differential balanced photodetection. Orthogonal codes eight bits long are compared, and matched codes are successfully distinguished from mismatched codes with very low error rates, of around 10-18. This technique has potential for high-speed, high accuracy recognition of bit-sequences, with applications in keyword searches and internet protocol packet routing.

  2. Chemical measurement of urine volume

    NASA Technical Reports Server (NTRS)

    Sauer, R. L.

    1978-01-01

    Chemical method of measuring volume of urine samples using lithium chloride dilution technique, does not interfere with analysis, is faster, and more accurate than standard volumetric of specific gravity/weight techniques. Adaptation of procedure to urinalysis could prove generally practical for hospital mineral balance and catechoamine determinations.

  3. Skylab water balance error analysis

    NASA Technical Reports Server (NTRS)

    Leonard, J. I.

    1977-01-01

    Estimates of the precision of the net water balance were obtained for the entire Skylab preflight and inflight phases as well as for the first two weeks of flight. Quantitative estimates of both total sampling errors and instrumentation errors were obtained. It was shown that measurement error is minimal in comparison to biological variability and little can be gained from improvement in analytical accuracy. In addition, a propagation of error analysis demonstrated that total water balance error could be accounted for almost entirely by the errors associated with body mass changes. Errors due to interaction between terms in the water balance equation (covariances) represented less than 10% of the total error. Overall, the analysis provides evidence that daily measurements of body water changes obtained from the indirect balance technique are reasonable, precise, and relaible. The method is not biased toward net retention or loss.

  4. Adaptive Swarm Balancing Algorithms for rare-event prediction in imbalanced healthcare data

    PubMed Central

    Wong, Raymond K.; Mohammed, Sabah; Fiaidhi, Jinan; Sung, Yunsick

    2017-01-01

    Clinical data analysis and forecasting have made substantial contributions to disease control, prevention and detection. However, such data usually suffer from highly imbalanced samples in class distributions. In this paper, we aim to formulate effective methods to rebalance binary imbalanced dataset, where the positive samples take up only the minority. We investigate two different meta-heuristic algorithms, particle swarm optimization and bat algorithm, and apply them to empower the effects of synthetic minority over-sampling technique (SMOTE) for pre-processing the datasets. One approach is to process the full dataset as a whole. The other is to split up the dataset and adaptively process it one segment at a time. The experimental results reported in this paper reveal that the performance improvements obtained by the former methods are not scalable to larger data scales. The latter methods, which we call Adaptive Swarm Balancing Algorithms, lead to significant efficiency and effectiveness improvements on large datasets while the first method is invalid. We also find it more consistent with the practice of the typical large imbalanced medical datasets. We further use the meta-heuristic algorithms to optimize two key parameters of SMOTE. The proposed methods lead to more credible performances of the classifier, and shortening the run time compared to brute-force method. PMID:28753613

  5. Mass balance analysis of triclosan, diethyltoluamide, crotamiton and carbamazepine in sewage treatment plants.

    PubMed

    Nakada, N; Yasojima, M; Okayasu, Y; Komori, K; Suzuki, Y

    2010-01-01

    The behavior of antibacterial triclosan, insect-repellent diethyltoluamide (DEET), anticonvulsant carbamazepine, and antipruritic crotamiton was investigated at two sewage treatment plants (STPs) to clarify their complete mass balance. Twenty-four-hour flow-proportional composite samples were collected from the influent and effluent of primary and final sedimentation tanks, a biofiltration tank and disinfection tanks. Sludge samples (i.e., activated and excess sludge) and samples of the return flow from the sludge treatment process were collected in the same manner. The analytes in both the dissolved and particulate phases were individually determined by a gas chromatograph equipped with mass spectrometer. Triclosan was dominantly detected in the particulate phase especially in the early stage of treatment (up to 83%) and was efficiently removed (over 90%) in STPs, mainly by sorption to sewage sludge. Limited removal was observed for DEET (55+/-24%), while no significant removal was demonstrated for crotamiton or carbamazepine. The solid-water distribution coefficients (K(d), n=4) for triclosan (log K(d): 3.7-5.1), DEET (1.3-1.9) and crotamiton (1.1-1.6) in the sludge samples are also determined in this study. These findings indicate the limitations of current sewage treatment techniques for the removal of these water-soluble drugs (i.e. DEET, carbamazepine, and crotamiton).

  6. The reduced space Sequential Quadratic Programming (SQP) method for calculating the worst resonance response of nonlinear systems

    NASA Astrophysics Data System (ADS)

    Liao, Haitao; Wu, Wenwang; Fang, Daining

    2018-07-01

    A coupled approach combining the reduced space Sequential Quadratic Programming (SQP) method with the harmonic balance condensation technique for finding the worst resonance response is developed. The nonlinear equality constraints of the optimization problem are imposed on the condensed harmonic balance equations. Making use of the null space decomposition technique, the original optimization formulation in the full space is mathematically simplified, and solved in the reduced space by means of the reduced SQP method. The transformation matrix that maps the full space to the null space of the constrained optimization problem is constructed via the coordinate basis scheme. The removal of the nonlinear equality constraints is accomplished, resulting in a simple optimization problem subject to bound constraints. Moreover, second order correction technique is introduced to overcome Maratos effect. The combination application of the reduced SQP method and condensation technique permits a large reduction of the computational cost. Finally, the effectiveness and applicability of the proposed methodology is demonstrated by two numerical examples.

  7. [Effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patient with implant restoration].

    PubMed

    Wang, Rong; Xu, Xin

    2015-12-01

    To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced occlusal measuring standards. Using occlusion plane reduction adjustment technique, it is possible to obtain occlusion index and muscles of mastication's electromyogram index similar to the opposite side's natural dentition in patients with single unit fix prosthodontics crown and single posterior edentulous dentition without distal dentitions.

  8. No detectable effects of acute tryptophan depletion on short-term immune system cytokine levels in healthy adults.

    PubMed

    Hildebrandt, Caroline S; Helmbold, Katrin; Linden, Maike; Langen, Karl-Josef; Filss, C P; Runions, Kevin C; Stewart, Richard M; Rao, Pradeep; Moore, Julie K; Mahfouda, Simone; Morandini, Hugo A E; Wong, Janice W Y; Rink, Lothar; Zepf, Florian D

    2018-04-26

    Recent research suggested an influence of diminished central nervous serotonin (5-HT) synthesis on the leptin axis via immunological mechanisms in healthy adult females. However, studies assessing immunological parameters in combination with dietary challenge techniques that impact brain 5-HT synthesis in humans are lacking.  Methods: In the present trial, a pilot analysis was conducted on data obtained in healthy adult humans receiving either different dietary acute tryptophan depletion (ATD) challenge or tryptophan (TRP)-balanced control conditions (BAL) to study the effects of reduced central nervous 5-HT synthesis on serum tumor necrosis factor α (TNF-α), interleukin-1β (IL-1β) and IL-6 concentrations. The data of N = 35 healthy adults were analysed who were randomly subjected to one of the following two dietary conditions in a double-blind between-subject approach: (1) The Moja-De ATD challenge (ATD), or (2) TRP-balanced control condition for ATD Moja-De (BAL). Serum concentrations for the assessment of relevant parameters (TNF-α, IL-1β and IL-6) and relevant TRP-related characteristics after the respective challenge procedures were assessed at baseline (T0) and in hourly intervals after administration over a period of 6 h (T1-T6).  Results: The ATD condition did not result in significant changes to cytokine concentrations for the entire study sample, or in male and female subgroups. Depletion of CNS 5-HT via dietary TRP depletion appears to have no statistically significant short-term impact on cytokine concentrations in healthy adults.  Conclusions: Future research on immunological stressors in combination with challenge techniques will be of value in order to further disentangle the complex interplay between brain 5-HT synthesis and immunological pathways.

  9. Monitoring In Vivo Changes in Tonic Extracellular Dopamine Level by Charge-Balancing Multiple Waveform Fast-Scan Cyclic Voltammetry.

    PubMed

    Oh, Yoonbae; Park, Cheonho; Kim, Do Hyoung; Shin, Hojin; Kang, Yu Min; DeWaele, Mark; Lee, Jeyeon; Min, Hoon-Ki; Blaha, Charles D; Bennet, Kevin E; Kim, In Young; Lee, Kendall H; Jang, Dong Pyo

    2016-11-15

    Dopamine (DA) modulates central neuronal activity through both phasic (second to second) and tonic (minutes to hours) terminal release. Conventional fast-scan cyclic voltammetry (FSCV), in combination with carbon fiber microelectrodes, has been used to measure phasic DA release in vivo by adopting a background subtraction procedure to remove background capacitive currents. However, measuring tonic changes in DA concentrations using conventional FSCV has been difficult because background capacitive currents are inherently unstable over long recording periods. To measure tonic changes in DA concentrations over several hours, we applied a novel charge-balancing multiple waveform FSCV (CBM-FSCV), combined with a dual background subtraction technique, to minimize temporal variations in background capacitive currents. Using this method, in vitro, charge variations from a reference time point were nearly zero for 48 h, whereas with conventional background subtraction, charge variations progressively increased. CBM-FSCV also demonstrated a high selectivity against 3,4-dihydroxyphenylacetic acid and ascorbic acid, two major chemical interferents in the brain, yielding a sensitivity of 85.40 ± 14.30 nA/μM and limit of detection of 5.8 ± 0.9 nM for DA while maintaining selectivity. Recorded in vivo by CBM-FSCV, pharmacological inhibition of DA reuptake (nomifensine) resulted in a 235 ± 60 nM increase in tonic extracellular DA concentrations, while inhibition of DA synthesis (α-methyl-dl-tyrosine) resulted in a 72.5 ± 4.8 nM decrease in DA concentrations over a 2 h period. This study showed that CBM-FSCV may serve as a unique voltammetric technique to monitor relatively slow changes in tonic extracellular DA concentrations in vivo over a prolonged time period.

  10. Comparison of geodetic and glaciological mass-balance techniques, Gulkana Glacier, Alaska, U.S.A

    USGS Publications Warehouse

    Cox, L.H.; March, R.S.

    2004-01-01

    The net mass balance on Gulkana Glacier, Alaska, U.S.A., has been measured since 1966 by the glaciological method, in which seasonal balances are measured at three index sites and extrapolated over large areas of the glacier. Systematic errors can accumulate linearly with time in this method. Therefore, the geodetic balance, in which errors are less time-dependent, was calculated for comparison with the glaciological method. Digital elevation models of the glacier in 1974, 1993 and 1999 were prepared using aerial photographs, and geodetic balances were computed, giving - 6.0??0.7 m w.e. from 1974 to 1993 and - 11.8??0.7 m w.e. from 1974 to 1999. These balances are compared with the glaciological balances over the same intervals, which were - 5.8??0.9 and -11.2??1.0 m w.e. respectively; both balances show that the thinning rate tripled in the 1990s. These cumulative balances differ by <6%. For this close agreement, the glaciologically measured mass balance of Gulkana Glacier must be largely free of systematic errors and be based on a time-variable area-altitude distribution, and the photography used in the geodetic method must have enough contrast to enable accurate photogrammetry.

  11. Sensitivity of sensor-based sit-to-stand peak power to the effects of training leg strength, leg power and balance in older adults.

    PubMed

    Regterschot, G Ruben H; Folkersma, Marjanne; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    Increasing leg strength, leg power and overall balance can improve mobility and reduce fall risk. Sensor-based assessment of peak power during the sit-to-stand (STS) transfer may be useful for detecting changes in mobility and fall risk. Therefore, this study investigated whether sensor-based STS peak power and related measures are sensitive to the effects of increasing leg strength, leg power and overall balance in older adults. A further aim was to compare sensitivity between sensor-based STS measures and standard clinical measures of leg strength, leg power, balance, mobility and fall risk, following an exercise-based intervention. To achieve these aims, 26 older adults (age: 70-84 years) participated in an eight-week exercise program aimed at improving leg strength, leg power and balance. Before and after the intervention, performance on normal and fast STS transfers was evaluated with a hybrid motion sensor worn on the hip. In addition, standard clinical tests (isometric quadriceps strength, Timed Up and Go test, Berg Balance Scale) were performed. Standard clinical tests as well as sensor-based measures of peak power, maximal velocity and duration of normal and fast STS showed significant improvements. Sensor-based measurement of peak power, maximal velocity and duration of normal STS demonstrated a higher sensitivity (absolute standardized response mean (SRM): ≥ 0.69) to the effects of training leg strength, leg power and balance than standard clinical measures (absolute SRM: ≤ 0.61). Therefore, the presented sensor-based method appears to be useful for detecting changes in mobility and fall risk. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Saturated fluorescence measurements of the hydroxyl radical in laminar high-pressure flames

    NASA Technical Reports Server (NTRS)

    Carter, Campbell D.; King, Galen B.; Laurendeau, Normand M.

    1990-01-01

    The efficacy of laser saturated fluorescence (LSF) for OH concentration measurements in high pressure flames was studied theoretically and experimentally. Using a numerical model describing the interaction of hydroxyl with nonuniform laser excitation, the effect of pressure on the validity of the balanced cross-rate model was studied along with the sensitivity of the depopulation of the laser-coupled levels to the ratio of rate coefficients describing: (1) electronic quenching to (sup 2) Sigma (+) (v double prime greater than 0), and (2) vibrational relaxation from v double prime greater than 0 to v double prime = 0. At sufficiently high pressures and near-saturated conditions, the total population of the laser-coupled levels reaches an asymptotic value, which is insensitive to the degree of saturation. When the ratio of electronic quenching to vibrational relaxation is small and the rate of coefficients for rotational transfer in the ground and excited electronic states are nearly the same, the balanced cross-rate model remains a good approximation for all pressures. When the above ratio is large, depopulation of the laser-coupled levels becomes significant at high pressures, and thus the balanced cross-rate model no longer holds. Under these conditions, however, knowledge of the depletion of the laser-coupled levels can be used to correct the model. A combustion facility for operation up to 20 atm was developed to allow LSF measurements of OH in high pressure flames. Using this facility, partial saturation in laminar high pressure (less than or equal to 12.3 atm) C2H6/O2/N2 flames was achieved. To evaluate the limits of the balanced cross-rate model, absorption and calibrated LSF measurements at 3.1 and 6.1 atm were compared. The fluorescence voltages were calibrated with absorption measurements in an atmospheric flame and corrected for their finite sensitivity to quenching with: (1) estimated quenching rate coefficients, and (2) an in situ measurement from a technique employing two fluorescence detection geometries.

  13. A familial {open_quotes}balanced{close_quotes} 3;9 translocation with cryptic 8q insertion leading to deletion and duplication of 9p23 loci in siblings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wagstaff, J.; Hemann, M.

    1995-01-01

    A child with phenotypic features of the 9p{sup {minus}} syndrome, including metopic craniosynostosis, small ears, abdominal wall defect, and mental retardation, as well as hypopigmentation, was found to have a cytogenetically balanced 3;9 translocation, with breakpoints at 3p11 and 9p23, inherited from his phenotypically normal father. Molecular analysis showed heterozygous deletion of the TYRP (tyrosinase-related protein) locus, as well as loci D9S157, D9S274, D9S268, and D9S267, in the child but in neither parent. FISH analysis of the proband`s father indicated that loci deleted in his son, including TYRP, were present on neither the der(3) nor the der(9) translocation products butmore » had been inserted into the long arm of chromosome 8. Therefore, the apparent deletion of these loci in the proband was the result of meiotic segregation of the father`s 3;9 translocation chromosomes together with his normal chromosome 8 (not bearing the insertion from 9p23). Neither the deletion of these 9p23 loci from the translocation chromosomes nor their insertion into 8q was detectable by standard chromosome banding techniques. The proband`s sister exhibited speech delay, mild facial dysmorphism, and renal malformation, and her karyotype was 46,XX. Molecular analysis showed that she had inherited normal chromosomes 3 and 9, as well as the chromosome 8 with the insertion of 9p23 material, from her father. This analysis illustrates a new mechanism to explain cases in which an apparently balanced translocation has been transmitted from a normal parent to a child with a phenotypic abnormality: submicroscopic deletion of material from the translocation breakpoint and insertion into a third chromosome in the balanced parent, with meiotic segregation leading to loss of the inserted material in the child. 36 refs., 9 figs., 1 tab.« less

  14. Reliability, Validity, and Minimal Detectable Change of Balance Evaluation Systems Test and Its Short Versions in Older Cancer Survivors: A Pilot Study.

    PubMed

    Huang, Min H; Miller, Kara; Smith, Kristin; Fredrickson, Kayle; Shilling, Tracy

    2016-01-01

    Cancer is primarily a disease of older adults. About 77% of all cancers are diagnosed in persons aged 55 years and older. Cancer and its treatment can cause diverse sequelae impacting body systems underlying balance control. No study has examined the psychometric properties of balance assessment tools in older cancer survivors, presenting a significant challenge in the selection of outcome measures for clinicians treating this fast-growing population. This study aimed to determine the reliability, validity, and minimal detectable change (MDC) of the Balance Evaluation System Test (BESTest), Mini-Balance Evaluation Systems Test (Mini-BESTest), and Brief-Balance Evaluation Systems Test (Brief-BESTest) in community-dwelling older cancer survivors. This study was a cross-sectional design. Twenty breast and 8 prostate cancer survivors participated [age (SD) = 68.4 (8.13) years]. The BESTest and Activity-specific Balance Confidence (ABC) Scale were administered during the first session. Scores of Mini-BESTest and Brief-BESTest were extracted on the basis of the scores of BESTest. The BESTest was repeated within 1 to 2 weeks by the same rater to determine the test-retest reliability. For the analysis of the inter-rater reliability, 21 participants were randomly selected to be evaluated by 2 raters. A primary rater administered the test. The 2 raters independently and concurrently scored the performance of the participants. Each rater recorded the ratings separately on the scoring sheet. No discussion among the raters was allowed throughout the testing. Intraclass correlation coefficients (ICCs), standard error of measurement, minimal detectable change (MDC), and Bland-Altman plots were calculated. Concurrent validity of these balance tests with the ABC Scale was examined using the Spearman correlation. The BESTest, Mini-BESTest, and Brief-BESTest had high test-retest (ICC = 0.90-0.94) and interrater reliability (ICC = 0.86-0.96), small standard error of measurement (0.86-2.47 points), and MDC (2.39-6.86 points). The Bland-Altman plot revealed no systematic errors. The scores of BESTest, Mini-BEST, and Brief-BEST were correlated significantly with those of ABC Scale (P < .01), supporting their concurrent validity. The BESTest, Mini-BESTest, and Brief-BESTest showed high interrater and test-retest reliability, and excellent concurrent validity with the ABC Scale for community-dwelling cancer survivors aged 55 years and older who had completed cancer treatments for at least 3 months. Future studies are necessary to determine the predictive values for determining fall risks using balance assessment tools in older cancer survivors. Clinicians can utilize the BESTest and its short versions to evaluate balance problems in community-dwelling older cancer survivors and apply the established MDC to assess the intervention outcomes.

  15. A Distributed and Energy-Efficient Algorithm for Event K-Coverage in Underwater Sensor Networks

    PubMed Central

    Jiang, Peng; Xu, Yiming; Liu, Jun

    2017-01-01

    For event dynamic K-coverage algorithms, each management node selects its assistant node by using a greedy algorithm without considering the residual energy and situations in which a node is selected by several events. This approach affects network energy consumption and balance. Therefore, this study proposes a distributed and energy-efficient event K-coverage algorithm (DEEKA). After the network achieves 1-coverage, the nodes that detect the same event compete for the event management node with the number of candidate nodes and the average residual energy, as well as the distance to the event. Second, each management node estimates the probability of its neighbor nodes’ being selected by the event it manages with the distance level, the residual energy level, and the number of dynamic coverage event of these nodes. Third, each management node establishes an optimization model that uses expectation energy consumption and the residual energy variance of its neighbor nodes and detects the performance of the events it manages as targets. Finally, each management node uses a constrained non-dominated sorting genetic algorithm (NSGA-II) to obtain the Pareto set of the model and the best strategy via technique for order preference by similarity to an ideal solution (TOPSIS). The algorithm first considers the effect of harsh underwater environments on information collection and transmission. It also considers the residual energy of a node and a situation in which the node is selected by several other events. Simulation results show that, unlike the on-demand variable sensing K-coverage algorithm, DEEKA balances and reduces network energy consumption, thereby prolonging the network’s best service quality and lifetime. PMID:28106837

  16. A Distributed and Energy-Efficient Algorithm for Event K-Coverage in Underwater Sensor Networks.

    PubMed

    Jiang, Peng; Xu, Yiming; Liu, Jun

    2017-01-19

    For event dynamic K-coverage algorithms, each management node selects its assistant node by using a greedy algorithm without considering the residual energy and situations in which a node is selected by several events. This approach affects network energy consumption and balance. Therefore, this study proposes a distributed and energy-efficient event K-coverage algorithm (DEEKA). After the network achieves 1-coverage, the nodes that detect the same event compete for the event management node with the number of candidate nodes and the average residual energy, as well as the distance to the event. Second, each management node estimates the probability of its neighbor nodes' being selected by the event it manages with the distance level, the residual energy level, and the number of dynamic coverage event of these nodes. Third, each management node establishes an optimization model that uses expectation energy consumption and the residual energy variance of its neighbor nodes and detects the performance of the events it manages as targets. Finally, each management node uses a constrained non-dominated sorting genetic algorithm (NSGA-II) to obtain the Pareto set of the model and the best strategy via technique for order preference by similarity to an ideal solution (TOPSIS). The algorithm first considers the effect of harsh underwater environments on information collection and transmission. It also considers the residual energy of a node and a situation in which the node is selected by several other events. Simulation results show that, unlike the on-demand variable sensing K-coverage algorithm, DEEKA balances and reduces network energy consumption, thereby prolonging the network's best service quality and lifetime.

  17. All-optical optoacoustic microscopy system based on probe beam deflection technique

    NASA Astrophysics Data System (ADS)

    Maswadi, Saher M.; Tsyboulskic, Dmitri; Roth, Caleb C.; Glickman, Randolph D.; Beier, Hope T.; Oraevsky, Alexander A.; Ibey, Bennett L.

    2016-03-01

    It is difficult to achieve sub-micron resolution in backward mode OA microscopy using conventional piezoelectric detectors, because of wavefront distortions caused by components placed in the optical path, between the sample and the objective lens, that are required to separate the acoustic wave from the optical beam. As an alternate approach, an optoacoustic microscope (OAM) was constructed using the probe beam deflection technique (PBDT) to detect laserinduced acoustic signals. The all-optical OAM detects laser-generated pressure waves using a probe beam passing through a coupling medium, such as water, filling the space between the microscope objective lens and sample. The acoustic waves generated in the sample propagate through the coupling medium, causing transient changes in the refractive index that deflect the probe beam. These deflections are measured with a high-speed, balanced photodiode position detector. The deflection amplitude is directly proportional to the magnitude of the acoustic pressure wave, and provides the data required for image reconstruction. The sensitivity of the PBDT detector expressed as noise equivalent pressure was 12 Pa, comparable to that of existing high-performance ultrasound detectors. Because of the unimpeded working distance, a high numerical aperture objective lens, i.e. NA = 1, was employed in the OAM to achieve near diffraction-limited lateral resolution of 0.5 μm at 532nm. The all-optical OAM provides several benefits over current piezoelectric detector-based systems, such as increased lateral and axial resolution, higher sensitivity, robustness, and potentially more compatibility with multimodal instruments.

  18. Quantitative Graphics in Newspapers.

    ERIC Educational Resources Information Center

    Tankard, James W., Jr.

    The use of quantitative graphics in newspapers requires achieving a balance between being accurate and getting the attention of the reader. The statistical representations in newspapers are drawn by graphic designers whose key technique is fusion--the striking combination of two visual images. This technique often results in visual puns,…

  19. [Specific body care techniques in children].

    PubMed

    Petit, Didier

    2011-06-01

    Body care in the child is not limited to an essential act of somatic survival. It involves introducing attentive observation and in particular behavioural and affective interaction, in order to support the child's psychological balance. There are several care techniques which can be used to implement body mediation.

  20. Natural resource inventory for urban planning utilizing remote sensing techniques

    NASA Technical Reports Server (NTRS)

    Foster, K. E.; Mackey, P. F.; Bonham, C. D.

    1972-01-01

    Remote sensing techniques were applied to the lower Pantano Wash area to acquire data for planning an ecological balance between the expanding Tucson metropolitan area and its environment. The types and distribution of vegetation are discussed along with the hydrologic aspects of the Wash.

  1. Modified bathroom scale and balance assessment: a comparison with clinical tests.

    PubMed

    Duchêne, Jacques; Hewson, David; Rumeau, Pierre

    2016-01-01

    Frailty and detection of fall risk are major issues in preventive gerontology. A simple tool frequently used in daily life, a bathroom scale (balance quality tester: BQT), was modified to obtain information on the balance of 84 outpatients consulting at a geriatric clinic. The results computed from the BQT were compared to the values of three geriatric tests that are widely used either to detect a fall risk or frailty (timed get up and go: TUG; 10 m walking speed: WS; walking time: WT; one-leg stand: OS). The BQT calculates four parameters that are then scored and weighted, thus creating an overall indicator of balance quality. Raw data, partial scores and the global score were compared with the results of the three geriatric tests. The WT values had the highest correlation with BQT raw data (r = 0.55), while TUG (r = 0.53) and WS (r = 0.56) had the highest correlation with BQT partial scores. ROC curves for OS cut-off values (4 and 5 s) were produced, with the best results obtained for a 5 s cut-off, both with the partial scores combined using Fisher's combination (specificity 85 %: <0.11, sensitivity 85 %: >0.48), and with the empirical score (specificity 85 %: <7, sensitivity 85 %: >8). A BQT empirical score of less than seven can detect fall risk in a community dwelling population.

  2. NASA Tech Briefs, September 2012

    NASA Technical Reports Server (NTRS)

    2012-01-01

    Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

  3. Reduced-order modeling for hyperthermia control.

    PubMed

    Potocki, J K; Tharp, H S

    1992-12-01

    This paper analyzes the feasibility of using reduced-order modeling techniques in the design of multiple-input, multiple-output (MIMO) hyperthermia temperature controllers. State space thermal models are created based upon a finite difference expansion of the bioheat transfer equation model of a scanned focused ultrasound system (SFUS). These thermal state space models are reduced using the balanced realization technique, and an order reduction criterion is tabulated. Results show that a drastic reduction in model dimension can be achieved using the balanced realization. The reduced-order model is then used to design a reduced-order optimal servomechanism controller for a two-scan input, two thermocouple output tissue model. In addition, a full-order optimal servomechanism controller is designed for comparison and validation purposes. These two controllers are applied to a variety of perturbed tissue thermal models to test the robust nature of the reduced-order controller. A comparison of the two controllers validates the use of open-loop balanced reduced-order models in the design of MIMO hyperthermia controllers.

  4. Incentives for Cheating Given Imperfect Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Canavan, G.H.

    1998-10-01

    The incentives for cheating given imperfect detection can be discussed within the context of first strike stability. The cost reduction due to is balanced against the sanctions that would be imposed if cheating was detected. For small political sanctions, the optimum level is at high levels of cheating. For large sanctions, the optimum is at quite low levels, which discourages cheating.

  5. SeeSway - A free web-based system for analysing and exploring standing balance data.

    PubMed

    Clark, Ross A; Pua, Yong-Hao

    2018-06-01

    Computerised posturography can be used to assess standing balance, and can predict poor functional outcomes in many clinical populations. A key limitation is the disparate signal filtering and analysis techniques, with many methods requiring custom computer programs. This paper discusses the creation of a freely available web-based software program, SeeSway (www.rehabtools.org/seesway), which was designed to provide powerful tools for pre-processing, analysing and visualising standing balance data in an easy to use and platform independent website. SeeSway links an interactive web platform with file upload capability to software systems including LabVIEW, Matlab, Python and R to perform the data filtering, analysis and visualisation of standing balance data. Input data can consist of any signal that comprises an anterior-posterior and medial-lateral coordinate trace such as center of pressure or mass displacement. This allows it to be used with systems including criterion reference commercial force platforms and three dimensional motion analysis, smartphones, accelerometers and low-cost technology such as Nintendo Wii Balance Board and Microsoft Kinect. Filtering options include Butterworth, weighted and unweighted moving average, and discrete wavelet transforms. Analysis methods include standard techniques such as path length, amplitude, and root mean square in addition to less common but potentially promising methods such as sample entropy, detrended fluctuation analysis and multiresolution wavelet analysis. These data are visualised using scalograms, which chart the change in frequency content over time, scatterplots and standard line charts. This provides the user with a detailed understanding of their results, and how their different pre-processing and analysis method selections affect their findings. An example of the data analysis techniques is provided in the paper, with graphical representation of how advanced analysis methods can better discriminate between someone with neurological impairment and a healthy control. The goal of SeeSway is to provide a simple yet powerful educational and research tool to explore how standing balance is affected in aging and clinical populations. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. An evaluation of HEMT potential for millimeter-wave signal sources using interpolation and harmonic balance techniques

    NASA Technical Reports Server (NTRS)

    Kwon, Youngwoo; Pavlidis, Dimitris; Tutt, Marcel N.

    1991-01-01

    A large-signal analysis method based on an harmonic balance technique and a 2-D cubic spline interpolation function has been developed and applied to the prediction of InP-based HEMT oscillator performance for frequencies extending up to the submillimeter-wave range. The large-signal analysis method uses a limited number of DC and small-signal S-parameter data and allows the accurate characterization of HEMT large-signal behavior. The method has been validated experimentally using load-pull measurement. Oscillation frequency, power performance, and load requirements are discussed, with an operation capability of 300 GHz predicted using state-of-the-art devices (fmax is approximately equal to 450 GHz).

  7. Test techniques: A survey paper on cryogenic tunnels, adaptive wall test sections, and magnetic suspension and balance systems

    NASA Technical Reports Server (NTRS)

    Kilgore, Robert A.; Dress, David A.; Wolf, Stephen W. D.; Britcher, Colin P.

    1989-01-01

    The ability to get good experimental data in wind tunnels is often compromised by things seemingly beyond our control. Inadequate Reynolds number, wall interference, and support interference are three of the major problems in wind tunnel testing. Techniques for solving these problems are available. Cryogenic wind tunnels solve the problem of low Reynolds number. Adaptive wall test sections can go a long way toward eliminating wall interference. A magnetic suspension and balance system (MSBS) completely eliminates support interference. Cryogenic tunnels, adaptive wall test sections, and MSBS are surveyed. A brief historical overview is given and the present state of development and application in each area is described.

  8. Balancing generality and specificity in component-based reuse

    NASA Technical Reports Server (NTRS)

    Eichmann, David A.; Beck, Jon

    1992-01-01

    For a component industry to be successful, we must move beyond the current techniques of black box reuse and genericity to a more flexible framework supporting customization of components as well as instantiation and composition of components. Customization of components strikes a balanced between creating dozens of variations of a base component and requiring the overhead of unnecessary features of an 'everything but the kitchen sink' component. We argue that design and instantiation of reusable components have competing criteria - design-for-use strives for generality, design-with-reuse strives for specificity - and that providing mechanisms for each can be complementary rather than antagonistic. In particular, we demonstrate how program slicing techniques can be applied to customization of reusable components.

  9. Water balance models in one-month-ahead streamflow forecasting

    USGS Publications Warehouse

    Alley, William M.

    1985-01-01

    Techniques are tested that incorporate information from water balance models in making 1-month-ahead streamflow forecasts in New Jersey. The results are compared to those based on simple autoregressive time series models. The relative performance of the models is dependent on the month of the year in question. The water balance models are most useful for forecasts of April and May flows. For the stations in northern New Jersey, the April and May forecasts were made in order of decreasing reliability using the water-balance-based approaches, using the historical monthly means, and using simple autoregressive models. The water balance models were useful to a lesser extent for forecasts during the fall months. For the rest of the year the improvements in forecasts over those obtained using the simpler autoregressive models were either very small or the simpler models provided better forecasts. When using the water balance models, monthly corrections for bias are found to improve minimum mean-square-error forecasts as well as to improve estimates of the forecast conditional distributions.

  10. Clinical avian nutrition.

    PubMed

    Orosz, Susan E

    2014-09-01

    Psittacine birds eat plant-based foods. Birds in the wild seem to be able to balance their energy needs, amino acids, and calcium. Companion birds in captivity do not do as well when self-selecting, and balanced diets are needed to improve their general health. A nutritional history is important to determine whether the avian patient is in balance nutritionally. Understanding the various sources of the fat-soluble vitamins, calcium, and protein will help guide clients to provide nutritious foods for their birds. Owners need to learn to use foraging as a major source of their bird's diet and techniques. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Effects of partitioning and scheduling sparse matrix factorization on communication and load balance

    NASA Technical Reports Server (NTRS)

    Venugopal, Sesh; Naik, Vijay K.

    1991-01-01

    A block based, automatic partitioning and scheduling methodology is presented for sparse matrix factorization on distributed memory systems. Using experimental results, this technique is analyzed for communication and load imbalance overhead. To study the performance effects, these overheads were compared with those obtained from a straightforward 'wrap mapped' column assignment scheme. All experimental results were obtained using test sparse matrices from the Harwell-Boeing data set. The results show that there is a communication and load balance tradeoff. The block based method results in lower communication cost whereas the wrap mapped scheme gives better load balance.

  12. Mass-balance measurements in Alaska and suggestions for simplified observation programs

    USGS Publications Warehouse

    Trabant, D.C.; March, R.S.

    1999-01-01

    US Geological Survey glacier fieldwork in Alaska includes repetitious measurements, corrections for leaning or bending stakes, an ability to reliably measure seasonal snow as deep as 10 m, absolute identification of summer surfaces in the accumulation area, and annual evaluation of internal accumulation, internal ablation, and glacier-thickness changes. Prescribed field measurement and note-taking techniques help eliminate field errors and expedite the interpretative process. In the office, field notes are transferred to computerized spread-sheets for analysis, release on the World Wide Web, and archival storage. The spreadsheets have error traps to help eliminate note-taking and transcription errors. Rigorous error analysis ends when mass-balance measurements are extrapolated and integrated with area to determine glacier and basin mass balances. Unassessable errors in the glacier and basin mass-balance data reduce the value of the data set for correlations with climate change indices. The minimum glacier mass-balance program has at least three measurement sites on a glacier and the measurements must include the seasonal components of mass balance as well as the annual balance.

  13. Seeing the tipping point: Balance perception and visual shape.

    PubMed

    Firestone, Chaz; Keil, Frank C

    2016-07-01

    In a brief glance at an object or shape, we can appreciate a rich suite of its functional properties, including the organization of the object's parts, its optimal contact points for grasping, and its center of mass, or balancing point. However, in the real world and the laboratory, balance perception shows systematic biases whereby observers may misjudge a shape's center of mass by a severe margin. Are such biases simply quirks of physical reasoning? Or might they instead reflect more fundamental principles of object representation? Here we demonstrate systematically biased center-of-mass estimation for two-dimensional (2D) shapes (Study 1) and advance a surprising explanation of such biases. We suggest that the mind implicitly represents ordinary 2D shapes as rich, volumetric, three-dimensional (3D) objects, and that these "inflated" shape representations intrude on and bias perception of the 2D shape's geometric properties. Such "inflation" is a computer-graphics technique for segmenting shapes into parts, and we show that a model derived from this technique best accounts for the biases in center-of-mass estimation in Study 1. Further supporting this account, we show that reducing the need for inflated shape representations diminishes such biases: Center-of-mass estimation improved when cues to shapehood were attenuated (Study 2) and when shapes' depths were explicitly depicted using real-life objects laser-cut from wood (Study 3). We suggest that the technique of shape inflation is actually implemented in the mind; thus, biases in our impressions of balance reflect a more general functional characteristic of object perception. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  14. A Wireless Object Location Detector Enabling People with Developmental Disabilities to Control Environmental Stimulation through Simple Occupational Activities with Nintendo Wii Balance Boards

    ERIC Educational Resources Information Center

    Shih, Ching-Hsiang; Chang, Man-Ling

    2012-01-01

    The latest researches have adopted software technology, turning the Nintendo Wii Balance Board into a high performance standing location detector with a newly developed standing location detection program (SLDP). This study extended SLDP functionality to assess whether two people with developmental disabilities would be able to actively perform…

  15. A Standing Location Detector Enabling People with Developmental Disabilities to Control Environmental Stimulation through Simple Physical Activities with Nintendo Wii Balance Boards

    ERIC Educational Resources Information Center

    Shih, Ching-Hsiang

    2011-01-01

    This study evaluated whether two people with developmental disabilities would be able to actively perform simple physical activities by controlling their favorite environmental stimulation using Nintendo Wii Balance Boards with a newly developed standing location detection program (SLDP, i.e., a new software program turning a Nintendo Wii Balance…

  16. Validity, Responsiveness, Minimal Detectable Change, and Minimal Clinically Important Change of "Pediatric Balance Scale" in Children with Cerebral Palsy

    ERIC Educational Resources Information Center

    Chen, Chia-ling; Shen, I-hsuan; Chen, Chung-yao; Wu, Ching-yi; Liu, Wen-Yu; Chung, Chia-ying

    2013-01-01

    This study examined criterion-related validity and clinimetric properties of the pediatric balance scale ("PBS") in children with cerebral palsy (CP). Forty-five children with CP (age range: 19-77 months) and their parents participated in this study. At baseline and at follow up, Pearson correlation coefficients were used to determine…

  17. Viewing 3D TV over two months produces no discernible effects on balance, coordination or eyesight

    PubMed Central

    Read, Jenny C.A.; Godfrey, Alan; Bohr, Iwo; Simonotto, Jennifer; Galna, Brook; Smulders, Tom V.

    2016-01-01

    Abstract With the rise in stereoscopic 3D media, there has been concern that viewing stereoscopic 3D (S3D) content could have long-term adverse effects, but little data are available. In the first study to address this, 28 households who did not currently own a 3D TV were given a new TV set, either S3D or 2D. The 116 members of these households all underwent tests of balance, coordination and eyesight, both before they received their new TV set, and after they had owned it for 2 months. We did not detect any changes which appeared to be associated with viewing 3D TV. We conclude that viewing 3D TV does not produce detectable effects on balance, coordination or eyesight over the timescale studied. Practitioner Summary: Concern has been expressed over possible long-term effects of stereoscopic 3D (S3D). We looked for any changes in vision, balance and coordination associated with normal home S3D TV viewing in the 2 months after first acquiring a 3D TV. We find no evidence of any changes over this timescale. PMID:26758965

  18. Interrater and Intrarater Reliability of the Balance Computerized Adaptive Test in Patients With Stroke.

    PubMed

    Chiang, Hsin-Yu; Lu, Wen-Shian; Yu, Wan-Hui; Hsueh, I-Ping; Hsieh, Ching-Lin

    2018-04-11

    To examine the interrater and intrarater reliability of the Balance Computerized Adaptive Test (Balance CAT) in patients with chronic stroke having a wide range of balance functions. Repeated assessments design (1wk apart). Seven teaching hospitals. A pooled sample (N=102) including 2 independent groups of outpatients (n=50 for the interrater reliability study; n=52 for the intrarater reliability study) with chronic stroke. Not applicable. Balance CAT. For the interrater reliability study, the values of intraclass correlation coefficient, minimal detectable change (MDC), and percentage of MDC (MDC%) for the Balance CAT were .84, 1.90, and 31.0%, respectively. For the intrarater reliability study, the values of intraclass correlation coefficient, MDC, and MDC% ranged from .89 to .91, from 1.14 to 1.26, and from 17.1% to 18.6%, respectively. The Balance CAT showed sufficient intrarater reliability in patients with chronic stroke having balance functions ranging from sitting with support to independent walking. Although the Balance CAT may have good interrater reliability, we found substantial random measurement error between different raters. Accordingly, if the Balance CAT is used as an outcome measure in clinical or research settings, same raters are suggested over different time points to ensure reliable assessments. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  19. Sport simulation as a form of implicit motor training in a geriatric athlete after stroke: a case report.

    PubMed

    Young, Sonia N; VanWye, William R; Wallmann, Harvey W

    2018-06-25

    To describe the use of sport simulation activities as a form of implicit motor learning training with a geriatric former athlete following a stroke. An active 76-year-old former professional male softball player presented to outpatient physical therapy with medical history of right stroke with left hemiparesis 2 weeks following onset of symptoms of impaired balance, coordination, gait, and motor planning. Initial physical therapy included gait, balance, and coordination training. Additional sport-related balance and coordination activities were later added to the treatment plan. After approximately 3 weeks of treatment, the patient was able to return to work and had dramatically improved balance, coordination, and gait with sport simulation activities. Implicit motor learning techniques were incorporated through sport and job task simulation activities along with task-oriented neuromuscular reeducation. The patient demonstrated improvements with gait, balance, gross motor function, and decreased fall risk.

  20. An energy-aware routing protocol for query-based applications in wireless sensor networks.

    PubMed

    Ahvar, Ehsan; Ahvar, Shohreh; Lee, Gyu Myoung; Crespi, Noel

    2014-01-01

    Wireless sensor network (WSN) typically has energy consumption restriction. Designing energy-aware routing protocol can significantly reduce energy consumption in WSNs. Energy-aware routing protocols can be classified into two categories, energy savers and energy balancers. Energy saving protocols are used to minimize the overall energy consumed by a WSN, while energy balancing protocols attempt to efficiently distribute the consumption of energy throughout the network. In general terms, energy saving protocols are not necessarily good at balancing energy consumption and energy balancing protocols are not always good at reducing energy consumption. In this paper, we propose an energy-aware routing protocol (ERP) for query-based applications in WSNs, which offers a good trade-off between traditional energy balancing and energy saving objectives and supports a soft real time packet delivery. This is achieved by means of fuzzy sets and learning automata techniques along with zonal broadcasting to decrease total energy consumption.

  1. Mining balance disorders' data for the development of diagnostic decision support systems.

    PubMed

    Exarchos, T P; Rigas, G; Bibas, A; Kikidis, D; Nikitas, C; Wuyts, F L; Ihtijarevic, B; Maes, L; Cenciarini, M; Maurer, C; Macdonald, N; Bamiou, D-E; Luxon, L; Prasinos, M; Spanoudakis, G; Koutsouris, D D; Fotiadis, D I

    2016-10-01

    In this work we present the methodology for the development of the EMBalance diagnostic Decision Support System (DSS) for balance disorders. Medical data from patients with balance disorders have been analysed using data mining techniques for the development of the diagnostic DSS. The proposed methodology uses various data, ranging from demographic characteristics to clinical examination, auditory and vestibular tests, in order to provide an accurate diagnosis. The system aims to provide decision support for general practitioners (GPs) and experts in the diagnosis of balance disorders as well as to provide recommendations for the appropriate information and data to be requested at each step of the diagnostic process. Detailed results are provided for the diagnosis of 12 balance disorders, both for GPs and experts. Overall, the reported accuracy ranges from 59.3 to 89.8% for GPs and from 74.3 to 92.1% for experts. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. An Energy-Aware Routing Protocol for Query-Based Applications in Wireless Sensor Networks

    PubMed Central

    Crespi, Noel

    2014-01-01

    Wireless sensor network (WSN) typically has energy consumption restriction. Designing energy-aware routing protocol can significantly reduce energy consumption in WSNs. Energy-aware routing protocols can be classified into two categories, energy savers and energy balancers. Energy saving protocols are used to minimize the overall energy consumed by a WSN, while energy balancing protocols attempt to efficiently distribute the consumption of energy throughout the network. In general terms, energy saving protocols are not necessarily good at balancing energy consumption and energy balancing protocols are not always good at reducing energy consumption. In this paper, we propose an energy-aware routing protocol (ERP) for query-based applications in WSNs, which offers a good trade-off between traditional energy balancing and energy saving objectives and supports a soft real time packet delivery. This is achieved by means of fuzzy sets and learning automata techniques along with zonal broadcasting to decrease total energy consumption. PMID:24696640

  3. Variance Estimation Using Replication Methods in Structural Equation Modeling with Complex Sample Data

    ERIC Educational Resources Information Center

    Stapleton, Laura M.

    2008-01-01

    This article discusses replication sampling variance estimation techniques that are often applied in analyses using data from complex sampling designs: jackknife repeated replication, balanced repeated replication, and bootstrapping. These techniques are used with traditional analyses such as regression, but are currently not used with structural…

  4. Monolayer to MTS: using SEM, HIM, TEM and SERS to compare morphology, nanosensor uptake and redox potential in MCF7 cells

    NASA Astrophysics Data System (ADS)

    Jamieson, L. E.; Bell, A. P.; Harrison, D. J.; Campbell, C. J.

    2015-06-01

    Cellular redox potential is important for the control and regulation of a vast number of processes occurring in cells. When the fine redox potential balance within cells is disturbed it can have serious consequences such as the initiation or progression of disease. It is thought that a redox gradient develops in cancer tumours where the peripheral regions are well oxygenated and internal regions, further from vascular blood supply, become starved of oxygen and hypoxic. This makes treatment of these areas more challenging as, for example, radiotherapy relies on the presence of oxygen. Currently techniques for quantitative analysis of redox gradients are limited. Surface enhanced Raman scattering (SERS) nanosensors (NS) have been used to detect redox potential in a quantitative manner in monolayer cultured cells with many advantages over other techniques. This technique has considerable potential for use in multicellular tumour spheroids (MTS) - a three dimensional (3D) cell model which better mimics the tumour environment and gradients that develop. MTS are a more realistic model of the in vivo cellular morphology and environment and are becoming an increasingly popular in vitro model, replacing traditional monolayer culture. Imaging techniques such as transmission electron microscopy (TEM), scanning electron microscopy (SEM) and helium ion microscopy (HIM) were used to investigate differences in morphology and NS uptake in monolayer culture compared to MTS. After confirming NS uptake, the first SERS measurements revealing quantitative information on redox potential in MTS were performed.

  5. An analytical model for the detection of levitated nanoparticles in optomechanics

    NASA Astrophysics Data System (ADS)

    Rahman, A. T. M. Anishur; Frangeskou, A. C.; Barker, P. F.; Morley, G. W.

    2018-02-01

    Interferometric position detection of levitated particles is crucial for the centre-of-mass (CM) motion cooling and manipulation of levitated particles. In combination with balanced detection and feedback cooling, this system has provided picometer scale position sensitivity, zeptonewton force detection, and sub-millikelvin CM temperatures. In this article, we develop an analytical model of this detection system and compare its performance with experimental results allowing us to explain the presence of spurious frequencies in the spectra.

  6. Novel techniques for data decomposition and load balancing for parallel processing of vision systems: Implementation and evaluation using a motion estimation system

    NASA Technical Reports Server (NTRS)

    Choudhary, Alok Nidhi; Leung, Mun K.; Huang, Thomas S.; Patel, Janak H.

    1989-01-01

    Computer vision systems employ a sequence of vision algorithms in which the output of an algorithm is the input of the next algorithm in the sequence. Algorithms that constitute such systems exhibit vastly different computational characteristics, and therefore, require different data decomposition techniques and efficient load balancing techniques for parallel implementation. However, since the input data for a task is produced as the output data of the previous task, this information can be exploited to perform knowledge based data decomposition and load balancing. Presented here are algorithms for a motion estimation system. The motion estimation is based on the point correspondence between the involved images which are a sequence of stereo image pairs. Researchers propose algorithms to obtain point correspondences by matching feature points among stereo image pairs at any two consecutive time instants. Furthermore, the proposed algorithms employ non-iterative procedures, which results in saving considerable amounts of computation time. The system consists of the following steps: (1) extraction of features; (2) stereo match of images in one time instant; (3) time match of images from consecutive time instants; (4) stereo match to compute final unambiguous points; and (5) computation of motion parameters.

  7. Application of infrared thermal imaging in the study of preventing cardiovascular and cerebrovascular diseases with Chinese medicine health food

    NASA Astrophysics Data System (ADS)

    Li, Ziru; Zhang, Xusheng

    2009-08-01

    To explore the assessing technique which could objectively reflect the characteristics of Chinese medicine in the prevention of cardiovascular and cerebrovascular diseases, four balance features of infrared thermal images (ITI) corresponding to the up and down, left and right, proximal and distal balance of blood circulation of human body were studied. First, the ITI features of the middle-aged and elderly people with lipid abnormality history were compared with those of the healthy youth. It was found that the balance state of the youth was significantly better than that of the middle-aged and elderly, P<=0.01 for all the balance features. For the youth, the balance state of females was better than that of the males. But this sexual difference disappeared for the middle-aged and elderly group. Second, a double-blind randomized trial was carried out to study the influences of Shengyi capsule, a Chinese medicine health food with the function of helping to decrease serum lipid, on the balance features. The subjects were middle-aged and elderly people with lipid abnormality history. Shengyi capsule was taken by the trial group while Xuezhikang capsule (with lovastatin as the main effective component) by the control group for 108 days. The balance features of ITI showed that Shengyi was significantly better than Xuezhikang in improving the whole body balance of blood circulation (including the up and down, left and right, proximal and distal balance). The relative efficacy rate was 81.0% for the trial group and 33.3% for the control group, there was significant difference between the two groups (P=0.002). Shengyi could effectively decrease the low density lipoprotein cholesterol (LDL-C) but the effect of Xuezhikang in decreasing total cholesterol (TC) and LDL-C was better than Shengyi. Though the lipid-lowering effect of Shengyi was not as good as Xuezhikang, ITI reflected the obvious advantage of Shengyi in improving the whole body balance of blood circulation which indicated that helping to decrease serum lipid is only part of the health function of Shengyi. The physiology and pathology basis of the influences of Shengyi on the four balance features and its relationship with the clinical outcome deserves further study. So the prospect of infrared thermal imaging is indicated as the suitable evaluation technique which could objectively reflect the whole balance regulation advantage of Chinese medicinal compounds.

  8. Direct Determination of the Dependence of the Surface Shear and Dilatational Viscosities on the Thermodynamic State of the Interface: Theoretical Foundations.

    PubMed

    Lopez; Hirsa

    1998-10-01

    Recent developments in nonlinear optical techniques for noninvasive probing of a surfactant influenced gas/liquid interface allow for the measurement of the surfactant surface concentration, c, and thus provide new opportunities for the direct determination of its intrinsic viscosities. Here, we present the theoretical foundations, based on the Boussinesq-Scriven surface model without the usual simplification of constant viscosities, for an experimental technique to directly measure the surface shear (µs) and dilatational (kappas) viscosities of a Newtonian interface as functions of the surfactant surface concentration. This ability to directly measure the surfactant concentration permits the use of a simple surface flow for the measurement of the surface viscosities. The requirements are that the interface must be nearly flat, and the flow steady, axisymmetric, and swirling; these flow conditions can be achieved in the deep-channel viscometer driven at relatively fast rates. The tangential stress balance on such an interface leads to two equations; the balance in the azimuthal direction involves only µs and its gradients, and the balance in the radial direction involves both µs and kappas and their gradients. By further exploiting recent developments in laser-based flow measuring techniques, the surface velocities and their gradients which appear in the two equations can be measured directly. The surface tension gradient, which appears in the radial balance equation, is incorporated from the equation of state for the surfactant system and direct measurements of the surfactant surface concentration distribution. The stress balance equations are then ordinary differential equations in the surface viscosities as functions of radial position, which can be readily integrated. Since c is measured as a function of radial position, we then have a direct measurement of µs and kappas as functions of c. Numerical computations of the Navier-Stokes equations are performed to determine the appropriate conditions to achieve the requisite secondary flow. Copyright 1998 Academic Press.

  9. Novel Application of FTIR Spectroscopy for the Passive Standoff Detection of Radiological Materials

    DTIC Science & Technology

    2006-08-01

    possibility of applying the long-wave passive standoff detection technique to the identification of radiological materials. This work is based on...infrared (FTIR) radiometry is a well-known technique for detecting and identifying chemical warfare agents. In addition to these potential threats...necessary tools and techniques available for detecting and identifying radioactive products. At present, the main detection techniques depend on methods

  10. Balance training using an interactive game to enhance the use of the affected side after stroke.

    PubMed

    Ciou, Shih-Hsiang; Hwang, Yuh-Shyan; Chen, Chih-Chen; Chen, Shih-Ching; Chou, Shih-Wei; Chen, Yu-Luen

    2015-12-01

    [Purpose] Stroke and other cerebrovascular diseases are major causes of adult mobility problems. Because stroke immobilizes the affected body part, balance training uses the healthy body part to complete the target movement. The muscle utilization rate on the stroke affected side is often reduced which further hinders affected side functional recovery in rehabilitation. [Subjects and Methods] This study tested a newly-developed interactive device with two force plates to measuring right and left side centers of pressure, to establish its efficacy in the improvement of the static standing ability of patients with hemiplegia. An interactive virtual reality game with different side reaction ratios was used to improve patient balance. The feasibility of the proposed approach was experimentally demonstrated. [Results] Although the non-affected-side is usually used to support the body weight in the standing position, under certain circumstances the patients could switch to using the affected side. A dramatic improvement in static standing balance control was achieved in the eyes open condition. [Conclusion] The proposed dual force plate technique used in this study separately measured the affected and non-affected-side centers of pressure. Based on this approach, different side ratio integration was achieved using an interactive game that helped stroke patients improve balance on the affected side. Only the patient who had suffered stroke relatively recently benefited significantly. The proposed technique is of little benefit for patients whose mobility has stagnated to a certain level.

  11. Effects of Cementing on Ligament Balance During Total Knee Arthroplasty.

    PubMed

    Chow, Jimmy; Wang, Kevin; Elson, Leah; Anderson, Christopher; Roche, Martin

    2017-05-01

    Complications related to joint imbalance may contribute to some of the most predominant modes of failure in total knee arthroplasty (TKA). These complications include instability, aseptic loosening, asymmetric component wear, and idiopathic pain. Fixation may represent a step that introduces unchecked variability into the procedure and may contribute to the incidence of joint imbalance-related complications. The ability to quantify in vivo loading in the medial and lateral compartments would allow for the ability to confirm balance after fixation and prior to wound closure. This retrospective study sought to capture any variability and imbalance associated with cementing technique. A total of 93 patients underwent sensor-assisted TKA. All patients were confirmed to have quantifiably balanced joints prior to cementation. After cementing and final component placement, the sensor was reinserted into the joint to capture any cementation-induced changes in loading. Imbalance was observed in 44% of patients after cementation. There was no difference in the proportion of imbalance due to surgeon experience (P=.456), cement type (P=.429), or knee system (P=.792). A majority of knees exhibited loading increase in the medial compartment. It was concluded that cementation technique contributes to a significant amount of balance-related variability at the fixation stage of the procedure. The use of the sensor in this study allowed for the correction of all instances of imbalance prior to closure. More objective methods of balance verification may be important for ensuring optimal surgical outcomes. [Orthopedics. 2017; 40(3):e455-e459.]. Copyright 2017, SLACK Incorporated.

  12. Effective crop evapotranspiration measurement using time-domain reflectometry technique in a sub-humid region

    NASA Astrophysics Data System (ADS)

    Srivastava, R. K.; Panda, R. K.; Halder, Debjani

    2017-08-01

    The primary objective of this study was to evaluate the performance of the time-domain reflectometry (TDR) technique for daily evapotranspiration estimation of peanut and maize crop in a sub-humid region. Four independent methods were used to estimate crop evapotranspiration (ETc), namely, soil water balance budgeting approach, energy balance approach—(Bowen ratio), empirical methods approach, and Pan evaporation method. The soil water balance budgeting approach utilized the soil moisture measurement by gravimetric and TDR method. The empirical evapotranspiration methods such as combination approach (FAO-56 Penman-Monteith and Penman), temperature-based approach (Hargreaves-Samani), and radiation-based approach (Priestley-Taylor, Turc, Abetw) were used to estimate the reference evapotranspiration (ET0). The daily ETc determined by the FAO-56 Penman-Monteith, Priestley-Taylor, Turc, Pan evaporation, and Bowen ratio were found to be at par with the ET values derived from the soil water balance budget; while the methods Abetw, Penman, and Hargreaves-Samani were not found to be ideal for the determination of ETc. The study illustrates the in situ applicability of the TDR method in order to make it possible for a user to choose the best way for the optimum water consumption for a given crop in a sub-humid region. The study suggests that the FAO-56 Penman-Monteith, Turc, and Priestley-Taylor can be used for the determination of crop ETc using TDR in comparison to soil water balance budget.

  13. A comparison of reduced-order modelling techniques for application in hyperthermia control and estimation.

    PubMed

    Bailey, E A; Dutton, A W; Mattingly, M; Devasia, S; Roemer, R B

    1998-01-01

    Reduced-order modelling techniques can make important contributions in the control and state estimation of large systems. In hyperthermia, reduced-order modelling can provide a useful tool by which a large thermal model can be reduced to the most significant subset of its full-order modes, making real-time control and estimation possible. Two such reduction methods, one based on modal decomposition and the other on balanced realization, are compared in the context of simulated hyperthermia heat transfer problems. The results show that the modal decomposition reduction method has three significant advantages over that of balanced realization. First, modal decomposition reduced models result in less error, when compared to the full-order model, than balanced realization reduced models of similar order in problems with low or moderate advective heat transfer. Second, because the balanced realization based methods require a priori knowledge of the sensor and actuator placements, the reduced-order model is not robust to changes in sensor or actuator locations, a limitation not present in modal decomposition. Third, the modal decomposition transformation is less demanding computationally. On the other hand, in thermal problems dominated by advective heat transfer, numerical instabilities make modal decomposition based reduction problematic. Modal decomposition methods are therefore recommended for reduction of models in which advection is not dominant and research continues into methods to render balanced realization based reduction more suitable for real-time clinical hyperthermia control and estimation.

  14. Adaptive Harmonic Detection Control of Grid Interfaced Solar Photovoltaic Energy System with Power Quality Improvement

    NASA Astrophysics Data System (ADS)

    Singh, B.; Goel, S.

    2015-03-01

    This paper presents a grid interfaced solar photovoltaic (SPV) energy system with a novel adaptive harmonic detection control for power quality improvement at ac mains under balanced as well as unbalanced and distorted supply conditions. The SPV energy system is capable of compensation of linear and nonlinear loads with the objectives of load balancing, harmonics elimination, power factor correction and terminal voltage regulation. The proposed control increases the utilization of PV infrastructure and brings down its effective cost due to its other benefits. The adaptive harmonic detection control algorithm is used to detect the fundamental active power component of load currents which are subsequently used for reference source currents estimation. An instantaneous symmetrical component theory is used to obtain instantaneous positive sequence point of common coupling (PCC) voltages which are used to derive inphase and quadrature phase voltage templates. The proposed grid interfaced PV energy system is modelled and simulated in MATLAB Simulink and its performance is verified under various operating conditions.

  15. [Comparison between rapid detection method of enzyme substrate technique and multiple-tube fermentation technique in water coliform bacteria detection].

    PubMed

    Sun, Zong-ke; Wu, Rong; Ding, Pei; Xue, Jin-Rong

    2006-07-01

    To compare between rapid detection method of enzyme substrate technique and multiple-tube fermentation technique in water coliform bacteria detection. Using inoculated and real water samples to compare the equivalence and false positive rate between two methods. Results demonstrate that enzyme substrate technique shows equivalence with multiple-tube fermentation technique (P = 0.059), false positive rate between the two methods has no statistical difference. It is suggested that enzyme substrate technique can be used as a standard method for water microbiological safety evaluation.

  16. Development of a clinical static and dynamic standing balance measurement tool appropriate for use in adolescents.

    PubMed

    Emery, Carolyn A; Cassidy, J David; Klassen, Terry P; Rosychuk, Rhonda J; Rowe, Brian B

    2005-06-01

    There is a need in sports medicine for a static and dynamic standing balance measure to quantify balance ability in adolescents. The purposes of this study were to determine the test-retest reliability of timed static (eyes open) and dynamic (eyes open and eyes closed) unipedal balance measurements and to examine factors associated with balance. Adolescents (n=123) were randomly selected from 10 Calgary high schools. This study used a repeated-measures design. One rater measured unipedal standing balance, including timed eyes-closed static (ECS), eyes-open dynamic (EOD), and eyes-closed dynamic (ECD) balance at baseline and 1 week later. Dynamic balance was measured on a foam surface. Reliability was examined using both intraclass correlation coefficients (ICCs) and Bland and Altman statistical techniques. Multiple linear regressions were used to examine other potentially influencing factors. Based on ICCs, test-retest reliability was adequate for ECS, EOD, and ECD balance (ICC=.69, .59, and .46, respectively). The results of Bland and Altman methods, however, suggest that caution is required in interpreting reliability based on ICCs alone. Although both ECS balance and ECD balance appear to demonstrate adequate test-retest reliability by ICC, Bland and Altman methods of agreement demonstrate sufficient reliability for ECD balance only. Thirty percent of the subjects reached the 180-second maximum on EOD balance, suggesting that this test is not appropriate for use in this population. Balance ability (ECS and ECD) was better in adolescents with no past history of lower-extremity injury. Timed ECD balance is an appropriate and reliable clinical measurement for use in adolescents and is influenced by previous injury.

  17. Validation of measures from the smartphone sway balance application: a pilot study.

    PubMed

    Patterson, Jeremy A; Amick, Ryan Z; Thummar, Tarunkumar; Rogers, Michael E

    2014-04-01

    A number of different balance assessment techniques are currently available and widely used. These include both subjective and objective assessments. The ability to provide quantitative measures of balance and posture is the benefit of objective tools, however these instruments are not generally utilized outside of research laboratory settings due to cost, complexity of operation, size, duration of assessment, and general practicality. The purpose of this pilot study was to assess the value and validity of using software developed to access the iPod and iPhone accelerometers output and translate that to the measurement of human balance. Thirty healthy college-aged individuals (13 male, 17 female; age = 26.1 ± 8.5 years) volunteered. Participants performed a static Athlete's Single Leg Test protocol for 10 sec, on a Biodex Balance System SD while concurrently utilizing a mobile device with balance software. Anterior/posterior stability was recorded using both devices, described as the displacement in degrees from level, and was termed the "balance score." There were no significant differences between the two reported balance scores (p = 0.818. Mean balance score on the balance platform was 1.41 ± 0.90, as compared to 1.38 ± 0.72 using the mobile device. There is a need for a valid, convenient, and cost-effective tool to objectively measure balance. Results of this study are promising, as balance score derived from the Smartphone accelerometers were consistent with balance scores obtained from a previously validated balance system. However, further investigation is necessary as this version of the mobile software only assessed balance in the anterior/posterior direction. Additionally, further testing is necessary on a healthy populations and as well as those with impairment of the motor control system. Level 2b (Observational study of validity)(1.)

  18. Balance and coordination after viewing stereoscopic 3D television

    PubMed Central

    Read, Jenny C. A.; Simonotto, Jennifer; Bohr, Iwo; Godfrey, Alan; Galna, Brook; Rochester, Lynn; Smulders, Tom V.

    2015-01-01

    Manufacturers and the media have raised the possibility that viewing stereoscopic 3D television (S3D TV) may cause temporary disruption to balance and visuomotor coordination. We looked for evidence of such effects in a laboratory-based study. Four hundred and thirty-three people aged 4–82 years old carried out tests of balance and coordination before and after viewing an 80 min movie in either conventional 2D or stereoscopic 3D, while wearing two triaxial accelerometers. Accelerometry produced little evidence of any change in body motion associated with S3D TV. We found no evidence that viewing the movie in S3D causes a detectable impairment in balance or in visuomotor coordination. PMID:26587261

  19. Thin-Wire Modeling Techniques Applied to Antenna Analysis.

    DTIC Science & Technology

    1974-10-11

    Ol- MULT11 CRN LOOP ANTENNA ... 30 2.4.1 Balanced vs unbalanced operation ... 3 1 2.4.2 Horizontal vs vertical configuration ... 33 3.0...of the Ml A-l Mimloop ... 28 Hl; multiturn loop antenna of Ohio State University ...31 Configurations ot balanced and unbalanced MTLs ... 32...4. Evaluation of Multiturn Loop Antenna In each example the specific project is outlined and the antenna analysis problems of particular interest

  20. Evaluation of alternative model-data fusion approaches in water balance estimation across Australia

    NASA Astrophysics Data System (ADS)

    van Dijk, A. I. J. M.; Renzullo, L. J.

    2009-04-01

    Australia's national agencies are developing a continental modelling system to provide a range of water information services. It will include rolling water balance estimation to underpin national water accounts, water resources assessments that interpret current water resources availability and trends in a historical context, and water resources predictions coupled to climate and weather forecasting. The nation-wide coverage, currency, accuracy, and consistency required means that remote sensing will need to play an important role along with in-situ observations. Different approaches to blending models and observations can be considered. Integration of on-ground and remote sensing data into land surface models in atmospheric applications often involves state updating through model-data assimilation techniques. By comparison, retrospective water balance estimation and hydrological scenario modelling to date has mostly relied on static parameter fitting against observations and has made little use of earth observation. The model-data fusion approach most appropriate for a continental water balance estimation system will need to consider the trade-off between computational overhead and the accuracy gains achieved when using more sophisticated synthesis techniques and additional observations. This trade-off was investigated using a landscape hydrological model and satellite-based estimates of soil moisture and vegetation properties for aseveral gauged test catchments in southeast Australia.

  1. Capillary Electrophoresis - Optical Detection Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sepaniak, M. J.

    2001-08-06

    Molecular recognition systems are developed via molecular modeling and synthesis to enhance separation performance in capillary electrophoresis and optical detection methods for capillary electrophoresis. The underpinning theme of our work is the rational design and development of molecular recognition systems in chemical separations and analysis. There have been, however, some subtle and exciting shifts in our research paradigm during this period. Specifically, we have moved from mostly separations research to a good balance between separations and spectroscopic detection for separations. This shift is based on our perception that the pressing research challenges and needs in capillary electrophoresis and electrokinetic chromatographymore » relate to the persistent detection and flow rate reproducibility limitations of these techniques (see page 1 of the accompanying Renewal Application for further discussion). In most of our work molecular recognition reagents are employed to provide selectivity and enhance performance. Also, an emerging trend is the use of these reagents with specially-prepared nano-scale materials. Although not part of our DOE BES-supported work, the modeling and synthesis of new receptors has indirectly supported the development of novel microcantilevers-based MEMS for the sensing of vapor and liquid phase analytes. This fortuitous overlap is briefly covered in this report. Several of the more significant publications that have resulted from our work are appended. To facilitate brevity we refer to these publications liberally in this progress report. Reference is also made to very recent work in the Background and Preliminary Studies Section of the Renewal Application.« less

  2. Virtual Reality-Based Center of Mass-Assisted Personalized Balance Training System.

    PubMed

    Kumar, Deepesh; González, Alejandro; Das, Abhijit; Dutta, Anirban; Fraisse, Philippe; Hayashibe, Mitsuhiro; Lahiri, Uttama

    2017-01-01

    Poststroke hemiplegic patients often show altered weight distribution with balance disorders, increasing their risk of fall. Conventional balance training, though powerful, suffers from scarcity of trained therapists, frequent visits to clinics to get therapy, one-on-one therapy sessions, and monotony of repetitive exercise tasks. Thus, technology-assisted balance rehabilitation can be an alternative solution. Here, we chose virtual reality as a technology-based platform to develop motivating balance tasks. This platform was augmented with off-the-shelf available sensors such as Nintendo Wii balance board and Kinect to estimate one's center of mass (CoM). The virtual reality-based CoM-assisted balance tasks (Virtual CoMBaT) was designed to be adaptive to one's individualized weight-shifting capability quantified through CoM displacement. Participants were asked to interact with Virtual CoMBaT that offered tasks of varying challenge levels while adhering to ankle strategy for weight shifting. To facilitate the patients to use ankle strategy during weight-shifting, we designed a heel lift detection module. A usability study was carried out with 12 hemiplegic patients. Results indicate the potential of our system to contribute to improving one's overall performance in balance-related tasks belonging to different difficulty levels.

  3. Basins of attraction in human balance

    NASA Astrophysics Data System (ADS)

    Smith, Victoria A.; Lockhart, Thurmon E.; Spano, Mark L.

    2017-12-01

    Falls are a recognized risk factor for unintentional injuries among older adults, accounting for a large proportion of fractures, emergency department visits, and urgent hospitalizations. Human balance and gait research traditionally uses linear or qualitative tests to assess and describe human motion; however, human motion is neither a simple nor a linear process. The objective of this research is to identify and to learn more about what factors affect balance using nonlinear dynamical techniques, such as basin boundaries. Human balance data was collected using dual force plates for leans using only ankle movements as well as for unrestricted leans. Algorithms to describe the basin boundary were created and compared based on how well each method encloses the experimental data points as well as captures the differences between the two leaning conditions.

  4. Development of a two-dimensional skin friction balance nulling circuit using multivariable control theory

    NASA Technical Reports Server (NTRS)

    Tripp, John S.; Patek, Stephen D.

    1988-01-01

    Measurement of planar skin friction forces in aerodynamic testing currently requires installation of two perpendicularly mounted, single-axis balances; consequently, force components must be sensed at two distinct locations. A two-axis instrument developed at the Langley Research Center to overcome this disadvantage allows measurement of a two-dimensional force at one location. This paper describes a feedback-controlled nulling circuit developed for the NASA two-axis balance which, without external compensation, is inherently unstable because of its low friction mechanical design. Linear multivariable control theory is applied to an experimentally validated mathematical model of the balance to synthesize a state-variable feedback control law. Pole placement techniques and computer simulation studies are employed to select eigenvalues which provide ideal transient response with decoupled sensing dynamics.

  5. A Single-Vector Force Calibration Method Featuring the Modern Design of Experiments

    NASA Technical Reports Server (NTRS)

    Parker, P. A.; Morton, M.; Draper, N.; Line, W.

    2001-01-01

    This paper proposes a new concept in force balance calibration. An overview of the state-of-the-art in force balance calibration is provided with emphasis on both the load application system and the experimental design philosophy. Limitations of current systems are detailed in the areas of data quality and productivity. A unique calibration loading system integrated with formal experimental design techniques has been developed and designated as the Single-Vector Balance Calibration System (SVS). This new concept addresses the limitations of current systems. The development of a quadratic and cubic calibration design is presented. Results from experimental testing are compared and contrasted with conventional calibration systems. Analyses of data are provided that demonstrate the feasibility of this concept and provide new insights into balance calibration.

  6. Noninvasive analysis of volatile biomarkers in human emanations for health and early disease diagnosis.

    PubMed

    Kataoka, Hiroyuki; Saito, Keita; Kato, Hisato; Masuda, Kazufumi

    2013-06-01

    Early disease diagnosis is crucial for human healthcare and successful therapy. Since any changes in homeostatic balance can alter human emanations, the components of breath exhalations and skin emissions may be diagnostic biomarkers for various diseases and metabolic disorders. Since hundreds of endogenous and exogenous volatile organic compounds (VOCs) are released from the human body, analysis of these VOCs may be a noninvasive, painless, and easy diagnostic tool. Sampling and preconcentration by sorbent tubes/traps and solid-phase microextraction, in combination with GC or GC-MS, are usually used to analyze VOCs. In addition, GC-MS-olfactometry is useful for simultaneous analysis of odorants and odor quality. Direct MS techniques are also useful for the online real-time detection of VOCs. This review focuses on recent developments in sampling and analysis of volatile biomarkers in human odors and/or emanations, and discusses future use of VOC analysis.

  7. Cervical cancer survival prediction using hybrid of SMOTE, CART and smooth support vector machine

    NASA Astrophysics Data System (ADS)

    Purnami, S. W.; Khasanah, P. M.; Sumartini, S. H.; Chosuvivatwong, V.; Sriplung, H.

    2016-04-01

    According to the WHO, every two minutes there is one patient who died from cervical cancer. The high mortality rate is due to the lack of awareness of women for early detection. There are several factors that supposedly influence the survival of cervical cancer patients, including age, anemia status, stage, type of treatment, complications and secondary disease. This study wants to classify/predict cervical cancer survival based on those factors. Various classifications methods: classification and regression tree (CART), smooth support vector machine (SSVM), three order spline SSVM (TSSVM) were used. Since the data of cervical cancer are imbalanced, synthetic minority oversampling technique (SMOTE) is used for handling imbalanced dataset. Performances of these methods are evaluated using accuracy, sensitivity and specificity. Results of this study show that balancing data using SMOTE as preprocessing can improve performance of classification. The SMOTE-SSVM method provided better result than SMOTE-TSSVM and SMOTE-CART.

  8. Field deployment of a scope for growth assay involving Gammarus pulex, a freshwater benthic invertebrate.

    PubMed

    Maltby, L; Naylor, C; Calow, P

    1990-06-01

    Scope for growth (SfG) is a measure of the energy balance of an animal (i.e., the difference between energy intake and metabolic output). The SfG of marine invertebrates, particularly the mussel Mytilus edulis, has been successfully used as the basis of a field bioassay to detect a range of stresses both natural (temperature, food, salinity) and anthropogenic (hydrocarbons, sewage sludge). SfG of the freshwater amphipod Gammarus pulex was found to be a sensitive indicator of stress under laboratory conditions and here we describe the field deployment of this technique and present data from three field trials. In every case, SfG was reduced at the downstream polluted site compared with that at an upstream reference site. This reduction in SfG was the result of a decrease in energy intake (absorption) rather than an increase in energy expenditure (respiration).

  9. Models and methods for in vitro testing of hepatic gap junctional communication.

    PubMed

    Maes, Michaël; Yanguas, Sara Crespo; Willebrords, Joost; Vinken, Mathieu

    2015-12-25

    Inherent to their pivotal roles in controlling all aspects of the liver cell life cycle, hepatocellular gap junctions are frequently disrupted upon impairment of the homeostatic balance, as occurs during liver toxicity. Hepatic gap junctions, which are mainly built up by connexin32, are specifically targeted by tumor promoters and epigenetic carcinogens. This renders inhibition of gap junction functionality a suitable indicator for the in vitro detection of nongenotoxic hepatocarcinogenicity. The establishment of a reliable liver gap junction inhibition assay for routine in vitro testing purposes requires a cellular system in which gap junctions are expressed at an in vivo-like level as well as an appropriate technique to probe gap junction activity. Both these models and methods are discussed in the current paper, thereby focusing on connexin32-based gap junctions. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Hyperspectral target detection using heavy-tailed distributions

    NASA Astrophysics Data System (ADS)

    Willis, Chris J.

    2009-09-01

    One promising approach to target detection in hyperspectral imagery exploits a statistical mixture model to represent scene content at a pixel level. The process then goes on to look for pixels which are rare, when judged against the model, and marks them as anomalies. It is assumed that military targets will themselves be rare and therefore likely to be detected amongst these anomalies. For the typical assumption of multivariate Gaussianity for the mixture components, the presence of the anomalous pixels within the training data will have a deleterious effect on the quality of the model. In particular, the derivation process itself is adversely affected by the attempt to accommodate the anomalies within the mixture components. This will bias the statistics of at least some of the components away from their true values and towards the anomalies. In many cases this will result in a reduction in the detection performance and an increased false alarm rate. This paper considers the use of heavy-tailed statistical distributions within the mixture model. Such distributions are better able to account for anomalies in the training data within the tails of their distributions, and the balance of the pixels within their central masses. This means that an improved model of the majority of the pixels in the scene may be produced, ultimately leading to a better anomaly detection result. The anomaly detection techniques are examined using both synthetic data and hyperspectral imagery with injected anomalous pixels. A range of results is presented for the baseline Gaussian mixture model and for models accommodating heavy-tailed distributions, for different parameterizations of the algorithms. These include scene understanding results, anomalous pixel maps at given significance levels and Receiver Operating Characteristic curves.

  11. Overview of hybridization and detection techniques.

    PubMed

    Hilario, Elena

    2007-01-01

    A misconception regarding the sensitivity of nonradioactive methods for screening genomic DNA libraries often hinders the establishment of these environmentally friendly techniques in molecular biology laboratories. Nonradioactive probes, properly prepared and quantified, can detect DNA target molecules to the femtomole range. However, appropriate hybridization techniques and detection methods should also be adopted for an efficient use of nonradioactive techniques. Detailed descriptions of genomic library handling before and during the nonradioactive hybridization and detection are often omitted from publications. This chapter aims to fill this void by providing a collection of technical tips on hybridization and detection techniques.

  12. AN INITIAL EVALUATION OF THE BTRACKS BALANCE PLATE AND SPORTS BALANCE SOFTWARE FOR CONCUSSION DIAGNOSIS

    PubMed Central

    Manyak, Kristin A.; Abdenour, Thomas E.; Rauh, Mitchell J.; Baweja, Harsimran S.

    2016-01-01

    Background As recently dictated by the American Medical Society, balance testing is an important component in the clinical evaluation of concussion. Despite this, previous research on the efficacy of balance testing for concussion diagnosis suggests low sensitivity (∼30%), based primarily on the popular Balance Error Scoring System (BESS). The Balance Tracking System (BTrackS, Balance Tracking Systems Inc., San Diego, CA, USA) consists of a force plate (BTrackS Balance Plate) and software (BTrackS Sport Balance) which can quickly (<2 min) perform concussion balance testing with gold standard accuracy. Purpose The present study aimed to determine the sensitivity of the BTrackS Balance Plate and Sports Balance Software for concussion diagnosis. Study Design Cross-Sectional Study Methods Preseason baseline balance testing of 519 healthy Division I college athletes playing sports with a relatively high risk for concussions was performed with the BTrackS Balance Test. Testing was administered by certified athletic training staff using the BTrackS Balance Plate and Sport Balance software. Of the baselined athletes, 25 later experienced a concussion during the ensuing sport season. Post-injury balance testing was performed on these concussed athletes within 48 of injury and the sensitivity of the BTrackS Balance Plate and Sport Balance software was estimated based on the number of athletes showing a balance decline according to the criteria specified in the Sport Balance software. This criteria is based on the minimal detectable change statistic with a 90% confidence level (i.e. 90% specificity). Results Of 25 athletes who experienced concussions, 16 had balance declines relative to baseline testing results according to the BTrackS Sport Balance software criteria. This corresponds to an estimated concussion sensitivity of 64%, which is twice as great as that reported previously for the BESS. Conclusions The BTrackS Balance Plate and Sport Balance software has the greatest concussion sensitivity of any balance testing instrument reported to date. Level of Evidence Level 2 (Individual cross sectional diagnostic study) PMID:27104048

  13. Recognizing human activities using appearance metric feature and kinematics feature

    NASA Astrophysics Data System (ADS)

    Qian, Huimin; Zhou, Jun; Lu, Xinbiao; Wu, Xinye

    2017-05-01

    The problem of automatically recognizing human activities from videos through the fusion of the two most important cues, appearance metric feature and kinematics feature, is considered. And a system of two-dimensional (2-D) Poisson equations is introduced to extract the more discriminative appearance metric feature. Specifically, the moving human blobs are first detected out from the video by background subtraction technique to form a binary image sequence, from which the appearance feature designated as the motion accumulation image and the kinematics feature termed as centroid instantaneous velocity are extracted. Second, 2-D discrete Poisson equations are employed to reinterpret the motion accumulation image to produce a more differentiated Poisson silhouette image, from which the appearance feature vector is created through the dimension reduction technique called bidirectional 2-D principal component analysis, considering the balance between classification accuracy and time consumption. Finally, a cascaded classifier based on the nearest neighbor classifier and two directed acyclic graph support vector machine classifiers, integrated with the fusion of the appearance feature vector and centroid instantaneous velocity vector, is applied to recognize the human activities. Experimental results on the open databases and a homemade one confirm the recognition performance of the proposed algorithm.

  14. Identifying Key Proteins in Hg Methylation Pathways of Desulfovibrio by Global Proteomics, Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Summers, Anne O.; Miller, Susan M.; Wall, Judy

    2016-06-18

    Elemental mercury, Hg(0) is a contaminant at many DOE sites, especially at Oak Ridge National Laboratory (ORNL) where the spread of spilled Hg and its effects on microbial populations have been monitored for decades. To explore the microbial interactions with Hg, we have devised a global proteomic approach capable of directly detecting Hg-adducts of proteins. This technique developed in the facultative anaerobe, Escherichia coli, allows us to identify the proteins most vulnerable to acute exposure to organomercurials phenyl- and ethyl-mercury (as surrogates for the highly neurotoxic methyl-Hg) (Polacco, et al, 2011). We have found >300 such proteins in all metabolicmore » functional groups and cellular compartments; most are highly conserved and can serve as markers for acute Hg exposure (Zink, et al. 2016, in preparation). We have also discovered that acute Hg exposure severely disrupts thiol, iron and redox homeostases, and electrolyte balance (LaVoie, et al., 2015) Thus, we proposed to bring these techniques to bear on the central problem of identifying the cellular proteins involved in bacterial uptake and methylation of mercury and its release from the cell.« less

  15. Balance Improvement Effects of Biofeedback Systems with State-of-the-Art Wearable Sensors: A Systematic Review.

    PubMed

    Ma, Christina Zong-Hao; Wong, Duo Wai-Chi; Lam, Wing Kai; Wan, Anson Hong-Ping; Lee, Winson Chiu-Chun

    2016-03-25

    Falls and fall-induced injuries are major global public health problems. Balance and gait disorders have been the second leading cause of falls. Inertial motion sensors and force sensors have been widely used to monitor both static and dynamic balance performance. Based on the detected performance, instant visual, auditory, electrotactile and vibrotactile biofeedback could be provided to augment the somatosensory input and enhance balance control. This review aims to synthesize the research examining the effect of biofeedback systems, with wearable inertial motion sensors and force sensors, on balance performance. Randomized and non-randomized clinical trials were included in this review. All studies were evaluated based on the methodological quality. Sample characteristics, device design and study characteristics were summarized. Most previous studies suggested that biofeedback devices were effective in enhancing static and dynamic balance in healthy young and older adults, and patients with balance and gait disorders. Attention should be paid to the choice of appropriate types of sensors and biofeedback for different intended purposes. Maximizing the computing capacity of the micro-processer, while minimizing the size of the electronic components, appears to be the future direction of optimizing the devices. Wearable balance-improving devices have their potential of serving as balance aids in daily life, which can be used indoors and outdoors.

  16. Balance Improvement Effects of Biofeedback Systems with State-of-the-Art Wearable Sensors: A Systematic Review

    PubMed Central

    Ma, Christina Zong-Hao; Wong, Duo Wai-Chi; Lam, Wing Kai; Wan, Anson Hong-Ping; Lee, Winson Chiu-Chun

    2016-01-01

    Falls and fall-induced injuries are major global public health problems. Balance and gait disorders have been the second leading cause of falls. Inertial motion sensors and force sensors have been widely used to monitor both static and dynamic balance performance. Based on the detected performance, instant visual, auditory, electrotactile and vibrotactile biofeedback could be provided to augment the somatosensory input and enhance balance control. This review aims to synthesize the research examining the effect of biofeedback systems, with wearable inertial motion sensors and force sensors, on balance performance. Randomized and non-randomized clinical trials were included in this review. All studies were evaluated based on the methodological quality. Sample characteristics, device design and study characteristics were summarized. Most previous studies suggested that biofeedback devices were effective in enhancing static and dynamic balance in healthy young and older adults, and patients with balance and gait disorders. Attention should be paid to the choice of appropriate types of sensors and biofeedback for different intended purposes. Maximizing the computing capacity of the micro-processer, while minimizing the size of the electronic components, appears to be the future direction of optimizing the devices. Wearable balance-improving devices have their potential of serving as balance aids in daily life, which can be used indoors and outdoors. PMID:27023558

  17. Evaluation of change detection techniques for monitoring coastal zone environments

    NASA Technical Reports Server (NTRS)

    Weismiller, R. A. (Principal Investigator); Kristof, S. J.; Scholz, D. K.; Anuta, P. E.; Momin, S. M.

    1977-01-01

    The author has identified the following significant results. Four change detection techniques were designed and implemented for evaluation: (1) post classification comparison change detection, (2) delta data change detection, (3) spectral/temporal change classification, and (4) layered spectral/temporal change classification. The post classification comparison technique reliably identified areas of change and was used as the standard for qualitatively evaluating the other three techniques. The layered spectral/temporal change classification and the delta data change detection results generally agreed with the post classification comparison technique results; however, many small areas of change were not identified. Major discrepancies existed between the post classification comparison and spectral/temporal change detection results.

  18. Balancing Instructional Techniques and Delivery Formats in Capstone Business Strategy Courses

    ERIC Educational Resources Information Center

    Alstete, Jeffrey W.; Beutell, Nicholas J.

    2016-01-01

    Purpose: The purpose of this paper is to contend that collegiate programs should carefully plan their capstone courses in light of the educational mission, pedagogical content knowledge, instructional techniques and delivery formats. Design/methodology/approach: This is a concept paper with elements of theory building from the case of business…

  19. Meeting the needs of an ever-demanding market.

    PubMed

    Rigby, Richard

    2002-04-01

    Balancing cost and performance in packaging is critical. This article outlines techniques to assist in this whilst delivering added value and product differentiation. The techniques include a rigorous statistical process capable of delivering cost reduction and improved quality and a computer modelling process that can save time when validating new packaging options.

  20. Beyond Music Sharing: An Evaluation of Peer-to-Peer Data Dissemination Techniques in Large Scientific Collaborations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ripeanu, Matei; Al-Kiswany, Samer; Iamnitchi, Adriana

    2009-03-01

    The avalanche of data from scientific instruments and the ensuing interest from geographically distributed users to analyze and interpret it accentuates the need for efficient data dissemination. A suitable data distribution scheme will find the delicate balance between conflicting requirements of minimizing transfer times, minimizing the impact on the network, and uniformly distributing load among participants. We identify several data distribution techniques, some successfully employed by today's peer-to-peer networks: staging, data partitioning, orthogonal bandwidth exploitation, and combinations of the above. We use simulations to explore the performance of these techniques in contexts similar to those used by today's data-centric scientificmore » collaborations and derive several recommendations for efficient data dissemination. Our experimental results show that the peer-to-peer solutions that offer load balancing and good fault tolerance properties and have embedded participation incentives lead to unjustified costs in today's scientific data collaborations deployed on over-provisioned network cores. However, as user communities grow and these deployments scale, peer-to-peer data delivery mechanisms will likely outperform other techniques.« less

  1. Performance evaluation and optimization of multiband phase-modulated radio over IsOWC link with balanced coherent homodyne detection

    NASA Astrophysics Data System (ADS)

    Zong, Kang; Zhu, Jiang

    2018-04-01

    In this paper, we present a multiband phase-modulated (PM) radio over intersatellite optical wireless communication (IsOWC) link with balanced coherent homodyne detection. The proposed system can provide the transparent transport of multiband radio frequency (RF) signals with higher linearity and better receiver sensitivity than intensity modulated with direct detection (IM/DD) system. The expressions of RF gain, noise figure (NF) and third-order spurious-free dynamic range (SFDR) are derived considering the third-order intermodulation product and amplifier spontaneous emission (ASE) noise. The optimal power of local oscillator (LO) optical signal is also derived theoretically. Numerical results for RF gain, NF and third-order SFDR are given for demonstration. Results indicate that the gain of the optical preamplifier and the power of LO optical signal should be optimized to obtain the satisfactory performance.

  2. Single-Vector Calibration of Wind-Tunnel Force Balances

    NASA Technical Reports Server (NTRS)

    Parker, P. A.; DeLoach, R.

    2003-01-01

    An improved method of calibrating a wind-tunnel force balance involves the use of a unique load application system integrated with formal experimental design methodology. The Single-Vector Force Balance Calibration System (SVS) overcomes the productivity and accuracy limitations of prior calibration methods. A force balance is a complex structural spring element instrumented with strain gauges for measuring three orthogonal components of aerodynamic force (normal, axial, and side force) and three orthogonal components of aerodynamic torque (rolling, pitching, and yawing moments). Force balances remain as the state-of-the-art instrument that provide these measurements on a scale model of an aircraft during wind tunnel testing. Ideally, each electrical channel of the balance would respond only to its respective component of load, and it would have no response to other components of load. This is not entirely possible even though balance designs are optimized to minimize these undesirable interaction effects. Ultimately, a calibration experiment is performed to obtain the necessary data to generate a mathematical model and determine the force measurement accuracy. In order to set the independent variables of applied load for the calibration 24 NASA Tech Briefs, October 2003 experiment, a high-precision mechanical system is required. Manual deadweight systems have been in use at Langley Research Center (LaRC) since the 1940s. These simple methodologies produce high confidence results, but the process is mechanically complex and labor-intensive, requiring three to four weeks to complete. Over the past decade, automated balance calibration systems have been developed. In general, these systems were designed to automate the tedious manual calibration process resulting in an even more complex system which deteriorates load application quality. The current calibration approach relies on a one-factor-at-a-time (OFAT) methodology, where each independent variable is incremented individually throughout its full-scale range, while all other variables are held at a constant magnitude. This OFAT approach has been widely accepted because of its inherent simplicity and intuitive appeal to the balance engineer. LaRC has been conducting research in a "modern design of experiments" (MDOE) approach to force balance calibration. Formal experimental design techniques provide an integrated view to the entire calibration process covering all three major aspects of an experiment; the design of the experiment, the execution of the experiment, and the statistical analyses of the data. In order to overcome the weaknesses in the available mechanical systems and to apply formal experimental techniques, a new mechanical system was required. The SVS enables the complete calibration of a six-component force balance with a series of single force vectors.

  3. Motion detection, novelty filtering, and target tracking using an interferometric technique with GaAs phase conjugate mirror

    NASA Technical Reports Server (NTRS)

    Cheng, Li-Jen (Inventor); Liu, Tsuen-Hsi (Inventor)

    1991-01-01

    A method and apparatus for detecting and tracking moving objects in a noise environment cluttered with fast- and slow-moving objects and other time-varying background. A pair of phase conjugate light beams carrying the same spatial information commonly cancel each other out through an image subtraction process in a phase conjugate interferometer, wherein gratings are formed in a fast photorefractive phase conjugate mirror material. In the steady state, there is no output. When the optical path of one of the two phase conjugate beams is suddenly changed, the return beam loses its phase conjugate nature and the interferometer is out of balance, resulting in an observable output. The observable output lasts until the phase conjugate nature of the beam has recovered. The observable time of the output signal is roughly equal to the formation time of the grating. If the optical path changing time is slower than the formation time, the change of optical path becomes unobservable, because the index grating can follow the change. Thus, objects traveling at speeds which result in a path changing time which is slower than the formation time are not observable and do not clutter the output image view.

  4. Detection of cancerous cervical cells using physical adhesion of fluorescent silica particles and centripetal force.

    PubMed

    Gaikwad, Ravi M; Dokukin, Maxim E; Iyer, K Swaminathan; Woodworth, Craig D; Volkov, Dmytro O; Sokolov, Igor

    2011-04-07

    Here we describe a non-traditional method to identify cancerous human cervical epithelial cells in a culture dish based on physical adhesion between silica beads and cells. It is a simple optical fluorescence-based technique which detects the relative difference in the amount of fluorescent silica beads physically adherent to surfaces of cancerous and normal cervical cells. The method utilizes the centripetal force gradient that occurs in a rotating culture dish. Due to the variation in the balance between adhesion and centripetal forces, cancerous and normal cells demonstrate clearly distinctive distributions of the fluorescent particles adherent to the cell surface over the culture dish. The method demonstrates higher adhesion of silica particles to normal cells compared to cancerous cells. The difference in adhesion was initially observed by atomic force microscopy (AFM). The AFM data were used to design the parameters of the rotational dish experiment. The optical method that we describe is much faster and technically simpler than AFM. This work provides proof of the concept that physical interactions can be used to accurately discriminate normal and cancer cells. © The Royal Society of Chemistry 2011

  5. Balance impairment in individuals with Wolfram syndrome

    PubMed Central

    Pickett, Kristen A.; Duncan, Ryan P.; Paciorkowski, Alex R.; Permutt, Alan; Marshall, Bess; Hershey, Tamara; Earhart, Gammon M.

    2012-01-01

    AIM Wolfram syndrome (WFS), a rare neurodegenerative disorder, is characterized by early onset insulin-dependent diabetes mellitus, optic atrophy, deafness, diabetes insipidus, and neurological abnormalities. Although previously unreported, we hypothesized that neurological complications may be detectable in relatively early stages of the disease. As the cerebellum and brainstem seem particularly vulnerable in WFS, we focused on balance functions critically dependent on these regions. The primary goal of this investigation was to compare balance in young individuals with WFS, in relatively early stages of the disease, to an age-matched cohort using a clinically applicable test. METHOD Balance was assessed via the mini-BESTest in 13 children, adolescents and young adults with WFS and 30 typically developing age-matched individuals. RESULTS A significant difference was observed between groups in balance as well as in three of four subcomponents of the mini-BESTest and in two timed tasks related to balance. Mini-BESTest scores were correlated with age (p < 0.001, rs = 0.59) among typically developing individuals. In the WFS group, mini-BESTest scores were related to overall motor dysfunction, but not age. INTERPRETATION Impairments in balance in WFS may occur earlier in the disease process than previously recognized and appear to be related to overall neurological progression rather than chronological age. Recognizing balance impairments and understanding which balance systems contribute to balance deficits in those with WFS may allow for development of effective patient-centered treatment paradigms. PMID:22771154

  6. Effects of activity and energy budget balancing algorithm on laboratory performance of a fish bioenergetics model

    USGS Publications Warehouse

    Madenjian, Charles P.; David, Solomon R.; Pothoven, Steven A.

    2012-01-01

    We evaluated the performance of the Wisconsin bioenergetics model for lake trout Salvelinus namaycush that were fed ad libitum in laboratory tanks under regimes of low activity and high activity. In addition, we compared model performance under two different model algorithms: (1) balancing the lake trout energy budget on day t based on lake trout energy density on day t and (2) balancing the lake trout energy budget on day t based on lake trout energy density on day t + 1. Results indicated that the model significantly underestimated consumption for both inactive and active lake trout when algorithm 1 was used and that the degree of underestimation was similar for the two activity levels. In contrast, model performance substantially improved when using algorithm 2, as no detectable bias was found in model predictions of consumption for inactive fish and only a slight degree of overestimation was detected for active fish. The energy budget was accurately balanced by using algorithm 2 but not by using algorithm 1. Based on the results of this study, we recommend the use of algorithm 2 to estimate food consumption by fish in the field. Our study results highlight the importance of accurately accounting for changes in fish energy density when balancing the energy budget; furthermore, these results have implications for the science of evaluating fish bioenergetics model performance and for more accurate estimation of food consumption by fish in the field when fish energy density undergoes relatively rapid changes.

  7. Toll-like receptor variation in the bottlenecked population of the Seychelles warbler: computer simulations see the 'ghost of selection past' and quantify the 'drift debt'.

    PubMed

    Gilroy, D L; Phillips, K P; Richardson, D S; van Oosterhout, C

    2017-07-01

    Balancing selection can maintain immunogenetic variation within host populations, but detecting its signal in a postbottlenecked population is challenging due to the potentially overriding effects of drift. Toll-like receptor genes (TLRs) play a fundamental role in vertebrate immune defence and are predicted to be under balancing selection. We previously characterized variation at TLR loci in the Seychelles warbler (Acrocephalus sechellensis), an endemic passerine that has undergone a historical bottleneck. Five of seven TLR loci were polymorphic, which is in sharp contrast to the low genomewide variation observed. However, standard population genetic statistical methods failed to detect a contemporary signature of selection at any TLR locus. We examined whether the observed TLR polymorphism could be explained by neutral evolution, simulating the population's demography in the software DIYABC. This showed that the posterior distributions of mutation rates had to be unrealistically high to explain the observed genetic variation. We then conducted simulations with an agent-based model using typical values for the mutation rate, which indicated that weak balancing selection has acted on the three TLR genes. The model was able to detect evidence of past selection elevating TLR polymorphism in the prebottleneck populations, but was unable to discern any effects of balancing selection in the contemporary population. Our results show drift is the overriding evolutionary force that has shaped TLR variation in the contemporary Seychelles warbler population, and the observed TLR polymorphisms might be merely the 'ghost of selection past'. Forecast models predict immunogenetic variation in this species will continue to be eroded in the absence of contemporary balancing selection. Such 'drift debt' occurs when a gene pool has not yet reached its new equilibrium level of polymorphism, and this loss could be an important threat to many recently bottlenecked populations. © 2017 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2017 European Society For Evolutionary Biology.

  8. Sterile insect technique: A model for dose optimisation for improved sterile insect quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, A.; Mehta, K.

    The sterile insect technique (SIT) is an environment-friendly pest control technique with application in the area-wide integrated control of key pests, including the suppression or elimination of introduced populations and the exclusion of new introductions. Reproductive sterility is normally induced by ionizing radiation, a convenient and consistent method that maintains a reasonable degree of competitiveness in the released insects. The cost and effectiveness of a control program integrating the SIT depend on the balance between sterility and competitiveness, but it appears that current operational programs with an SIT component are not achieving an appropriate balance. In this paper we discussmore » optimization of the sterilization process and present a simple model and procedure for determining the optimum dose. (author) [Spanish] La tecnica de insecto esteril (TIE) es una tecnologia de control de plagas favorable para el medio ambiente con una aplicacion de un control integrado de plagas claves para toda la area, incluyendo la supresion o eliminacion de poblaciones introducidas y la exclusion de nuevas introducciones. La esterilidad reproductiva es normalmente inducida por radiacion ionizada, un metodo conveniente y consistente que mantiene un grado razonable para la capacidad de competencia en insectos liberados. El costo y la eficacia de un programa de control que incluye TIE dependen en tener un balance entre la esterilidad y la capacidad para competir, pero parece que los programas operacionales corrientes con TIS como un componente no estan logrando el tener un balance apropiado. En esta publicacion, nosotros discutimos la optimizacion del proceso de esterilizacion y presentamos un modelo y procedimiento sencillos para determinar la dosis optima. (author)« less

  9. Satisfactory Short-Term Results of Navigation-Assisted Gap-Balancing Total Knee Arthroplasty Using Ultracongruent Insert.

    PubMed

    Yoon, Jung-Ro; Yang, Jae-Hyuk

    2018-03-01

    The use of highly conforming ultracongruent (UC) polyethylene insert is bone-preserving and became a relatively common alternative to the conventional posterior stabilized total knee arthroplasty (TKA) design. The purpose of this study was to analyze the short-term clinical and radiologic results of UC insert TKA using the navigation-assisted gap-balancing technique. Two hundred thirty-three knees were operated with a mean follow-up period of 8.1 years (minimum of 5 years). Radiologic and clinical outcomes were assessed before operation and at latest follow-up using the Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index score. For statistical analysis, paired sample t-test and analysis of variance were used. Significance was considered as P < .05. According to the preoperative deformities (valgus, mild varus, and moderate varus), there were 23 cases (9.9%) of valgus deformity, 180 cases (77.3%) of mild varus deformity, and 30 cases (12.9%) of moderate varus deformity. Overall, the results at mean 8.1 years revealed an improvement in mean Knee Society Score (54 ± 12 to 92 ± 3) and mean Western Ontario and McMaster Universities Osteoarthritis Index scores (62 ± 14 to 17 ± 3). Overall, 220 of 233 cases (94.4%) were in neutral alignment (between -3° and +3°) at latest follow-up. There were no migrating or shifting prosthesis that should be considered as possible failure. There was 0% component revision rate. Navigation-assisted gap-balancing technique using UC insert TKA had satisfactory short-term outcome. Strict gap-balancing technique using the offset-type-force-controlled-spreader-system aided in the satisfactory results. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Wet Removal of Organic and Black Carbon Aerosols

    NASA Astrophysics Data System (ADS)

    Torres, A.; Bond, T. C.; Lehmann, C.

    2012-12-01

    Organic carbon (OC) and black carbon (BC) aerosols derived from the combustion of fossil fuels and biomass are significant atmospheric pollutants that alter the Earth's radiation balance and affect human health. Carbonaceous aerosol lifetime and extent of its effects are mainly controlled by its wet removal, especially by rain. Limited work has been done to measure both BC and OC from rain events even though these aerosols are co-emitted and exist together in the atmosphere. The choices of analytical techniques for measuring OC and BC in water are limited, and researchers often employ the same techniques used for measuring atmospheric carbon particles. There is no agreement in the methods employed for monitoring carbon concentration in precipitation. As part of the method development, the Single Particle Soot Photometer (SP2), Thermal-Optical Analysis (TOA), Ultraviolet/Visible (UV/VIS) Spectrophotometer, and the Total Organic Carbon (TOC) Analyzer were evaluated for measuring BC suspended in water, water insoluble OC (WIOC) and dissolved OC (DOC). The study also monitored the concentration of BC, WIOC, and DOC in rainwater collected at Bondville (Illinois) for 18 months. Results indicated that 34% (±3%) of the BC mass was lost in the SP2 analysis, most probably during the nebulization process. Filtration required for TOA also had large losses (>75%) because quartz fiber filters were ineffective for capturing BC particles from water. Addition of NH4H2PO4 as a coagulant improved (>95%) the capture efficiency of the filters. UV/VIS spectrophotometry had good linearity, but the sensitivity for detecting BC particles (±20 μg/L) suspended in water was inadequate. TOC analysis was a robust technique for measuring both DOC and total carbon (BC + OC). The chosen techniques were TOC analysis for DOC, and TOA with an optimized filtration procedure for BC and WIOC. The mean concentrations in rainwater were 8.72 (±9.84) μg/L of BC, 88.97 (±62.64) μg/L of WIOC, and 1,320 (1,380) μg/L of DOC. DOC contributed, mostly with anions, to the ion balance of rain samples. The total carbon concentration (BC+WIOC+DOC) decreased with increasing precipitation volume and directly correlated with the concentrations of SO42-, NO3-, Ca2+, NH4+, Mg2+, and K+ in rainwater.

  11. Performance measurements of a pilot superconducting solenoid model core for a wind tunnel magnetic suspension and balance system

    NASA Technical Reports Server (NTRS)

    Goodyer, M. J.; Britcher, C. P.

    1983-01-01

    The results of experimental demonstrations of a superconducting solenoid model core in the Southampton University Magnetic Suspension and Balance System are detailed. Technology and techniques relevant to large-scale wind tunnel MSBSs comprise the long term goals. The magnetic moment of solenoids, difficulties peculiar to superconducting solenoid cores, lift force and pitching moment, dynamic lift calibration, and helium boil-off measurements are discussed.

  12. Assessing subacute mild traumatic brain injury with a portable virtual reality balance device.

    PubMed

    Wright, W Geoffrey; McDevitt, Jane; Tierney, Ryan; Haran, F Jay; Appiah-Kubi, Kwadwo Osei; Dumont, Alex

    2017-07-01

    Balance impairment is a common sensorimotor symptom in mild traumatic brain injury (mTBI). We designed an affordable, portable virtual reality (VR)-based balance screening device (Virtual Environment TBI Screen [VETS]), which will be validated relative to the Neurocom Sensory Organization Test (SOT) to determine if it can replace commonly used postural assessments. This preliminary study examines healthy adults (n = 56) and adults with mTBI (n = 11). Participants performed six upright postural tasks on the VETS and the SOT. Analysis of variance was used to determine between-group differences. Pearson's correlations were used to establish construct validity. Known-groups approach was used to establish classification accuracy. The mTBI cohort performed significantly worse than the healthy cohort on the new device (p = 0.001). The new device has 91.0% accuracy and an ROC curve with a significant area-under-the-curve (AUC = 0.865, p < 0.001). Conditions with dynamic visual stimulation were the most sensitive to health status. The SOT had an 84.8% accuracy and AUC =0.703 (p = 0.034). The new VR-based device is a valid measure for detecting balance impairment following mTBI and can potentially replace more expensive and cumbersome equipment. Assessments that test visual-vestibular processing, such as VETS, increase sensitivity to mTBI-related balance deficits, which can be used to guide rehabilitation. Implications for rehabilitation Emerging technology using virtual reality can be economically integrated into the clinical setting for easy testing of postural control in neurologically impaired populations. Tailoring postural assessments to include tasks that rely on visual and vestibular integration will increase the accuracy of detecting balance impairment following mild traumatic brain injury.

  13. Balancing benefit and risk of medicines: a systematic review and classification of available methodologies.

    PubMed

    Mt-Isa, Shahrul; Hallgreen, Christine E; Wang, Nan; Callréus, Torbjörn; Genov, Georgy; Hirsch, Ian; Hobbiger, Stephen F; Hockley, Kimberley S; Luciani, Davide; Phillips, Lawrence D; Quartey, George; Sarac, Sinan B; Stoeckert, Isabelle; Tzoulaki, Ioanna; Micaleff, Alain; Ashby, Deborah

    2014-07-01

    The need for formal and structured approaches for benefit-risk assessment of medicines is increasing, as is the complexity of the scientific questions addressed before making decisions on the benefit-risk balance of medicines. We systematically collected, appraised and classified available benefit-risk methodologies to facilitate and inform their future use. A systematic review of publications identified benefit-risk assessment methodologies. Methodologies were appraised on their fundamental principles, features, graphical representations, assessability and accessibility. We created a taxonomy of methodologies to facilitate understanding and choice. We identified 49 methodologies, critically appraised and classified them into four categories: frameworks, metrics, estimation techniques and utility survey techniques. Eight frameworks describe qualitative steps in benefit-risk assessment and eight quantify benefit-risk balance. Nine metric indices include threshold indices to measure either benefit or risk; health indices measure quality-of-life over time; and trade-off indices integrate benefits and risks. Six estimation techniques support benefit-risk modelling and evidence synthesis. Four utility survey techniques elicit robust value preferences from relevant stakeholders to the benefit-risk decisions. Methodologies to help benefit-risk assessments of medicines are diverse and each is associated with different limitations and strengths. There is not a 'one-size-fits-all' method, and a combination of methods may be needed for each benefit-risk assessment. The taxonomy introduced herein may guide choice of adequate methodologies. Finally, we recommend 13 of 49 methodologies for further appraisal for use in the real-life benefit-risk assessment of medicines. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Defense Departmental Reporting System-Budgetary Was Not Effectively Implemented for the Army General Fund

    DTIC Science & Technology

    2012-05-31

    or events. Unsupported journal vouchers increase the risk of materially misstated balances reported on the AGF financial statements. DFAS...with U.S. generally accepted accounting principles and that the Army automated systems did not support material amounts on the financial statements...files, abnormal balance detection , journal vouchers, and reconciliations between Army and OMB SF 133s and the Statements of Budgetary Resources

  15. An exergame system based on force platforms and body key-point detection for balance training.

    PubMed

    Lavarda, Marcos D; de Borba, Pedro A; Oliveira, Matheus R; Borba, Gustavo B; de Souza, Mauren A; Gamba, Humberto R

    2016-08-01

    Postural instability affects a large number of people and can compromise even simple activities of the daily routine. Therapies for balance training can strongly benefit from auxiliary devices specially designed for this purpose. In this paper, we present a system for balance training that uses the metaphor of a game, what contributes to the motivation and engagement of the patients during a treatment. Such approach is usually named exergame, in which input devices for posturographic assessment and a visual output perform the interaction with the subject. The proposed system uses two force platforms, one positioned under the feet and the other under the hip of the subject. The force platforms employ regular load cells and a microcontroller-based signal acquisition module to capture and transmit the samples to a computer. Moreover, a computer vision module performs body key-point detection, based on real time segmentation of markers attached to the subject. For the validation of the system, we conducted experiments with 20 neurologically intact volunteers during two tests: comparison of the stabilometric parameters obtained from the system with those obtained from a commercial baropodometer and the practice of several exergames. Results show that the proposed system is completely functional and can be used as a versatile tool for balance training.

  16. The Design Fabrication Installation & Evaluation of the Balance Probe Monitor for Large Centrifuges at a National Laboratory Facility.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gallegos, Jonathan Michael

    Balance Probe Monitors were designed, fabricated, installed, and evaluated at Sandia National Laboratories (SNL) for the 22,600 g kg (50,000 g lb) direct drive electromotor driven large centrifuges. These centrifuges provide a high onset/decay rate g environment. The Balance Probe Monitor is physically located near a centrifuge’s Capacitance Probe, a crucial sensor for the centrifuge’s sustainability. The Balance Probe Monitor will validate operability of the centrifuge. Most importantly, it is used for triggering a kill switch under the condition that the centrifuge displacement value exceeds allowed tolerances. During operational conditions, the Capacitance Probe continuously detects the structural displacement of themore » centrifuge and an adjoining AccuMeasure 9000 translates this displacement into an output voltage.« less

  17. Automated Video Quality Assessment for Deep-Sea Video

    NASA Astrophysics Data System (ADS)

    Pirenne, B.; Hoeberechts, M.; Kalmbach, A.; Sadhu, T.; Branzan Albu, A.; Glotin, H.; Jeffries, M. A.; Bui, A. O. V.

    2015-12-01

    Video provides a rich source of data for geophysical analysis, often supplying detailed information about the environment when other instruments may not. This is especially true of deep-sea environments, where direct visual observations cannot be made. As computer vision techniques improve and volumes of video data increase, automated video analysis is emerging as a practical alternative to labor-intensive manual analysis. Automated techniques can be much more sensitive to video quality than their manual counterparts, so performing quality assessment before doing full analysis is critical to producing valid results.Ocean Networks Canada (ONC), an initiative of the University of Victoria, operates cabled ocean observatories that supply continuous power and Internet connectivity to a broad suite of subsea instruments from the coast to the deep sea, including video and still cameras. This network of ocean observatories has produced almost 20,000 hours of video (about 38 hours are recorded each day) and an additional 8,000 hours of logs from remotely operated vehicle (ROV) dives. We begin by surveying some ways in which deep-sea video poses challenges for automated analysis, including: 1. Non-uniform lighting: Single, directional, light sources produce uneven luminance distributions and shadows; remotely operated lighting equipment are also susceptible to technical failures. 2. Particulate noise: Turbidity and marine snow are often present in underwater video; particles in the water column can have sharper focus and higher contrast than the objects of interest due to their proximity to the light source and can also influence the camera's autofocus and auto white-balance routines. 3. Color distortion (low contrast): The rate of absorption of light in water varies by wavelength, and is higher overall than in air, altering apparent colors and lowering the contrast of objects at a distance.We also describe measures under development at ONC for detecting and mitigating these effects. These steps include filtering out unusable data, color and luminance balancing, and choosing the most appropriate image descriptors. We apply these techniques to generate automated quality assessment of video data and illustrate their utility with an example application where we perform vision-based substrate classification.

  18. Non-Contrast-Enhanced Renal Angiography Using Multiple Inversion Recovery and Alternating TR Balanced Steady State Free Precession

    PubMed Central

    Dong, Hattie Z.; Worters, Pauline W.; Wu, Holden H.; Ingle, R. Reeve; Vasanawala, Shreyas S.; Nishimura, Dwight G.

    2014-01-01

    Non-contrast enhanced renal angiography techniques based on balanced steady state free precession (SSFP) avoid external contrast agents, take advantage of high inherent blood signal from the T2/T1 contrast mechanism, and have short SSFP acquisition times. However, background suppression is limited; inflow times are inflexible; labeling region is difficult to define when tagging arterial flow; and scan times are long. To overcome these limitations, we propose the use of multiple inversion recovery (MIR) preparatory pulses combined with alternating TR balanced SSFP (ATR-SSFP) to produce renal angiograms. MIR uses selective spatial saturation followed by four global inversion recovery pulses to concurrently null a wide range of background T1 species while allowing for adjustable inflow times; ATR-SSFP maintains vessel contrast and provides added fat suppression. The high level of suppression enables imaging in 3D as well as projective 2D formats, the latter of which has a scan time down to one heartbeat. In vivo studies at 1.5 T demonstrate the superior vessel contrast of this technique. PMID:23172805

  19. Drop-off Detection with the Long Cane: Effects of Different Cane Techniques on Performance

    PubMed Central

    Kim, Dae Shik; Emerson, Robert Wall; Curtis, Amy

    2010-01-01

    This study compared the drop-off detection performance with the two-point touch and constant contact cane techniques using a repeated-measures design with a convenience sample of 15 cane users with visual impairments. The constant contact technique was superior to the two-point touch technique in the drop-off detection rate and the 50% detection threshold. The findings may help an orientation and mobility instructor select an appropriate technique for a particular client or training situation. PMID:21209791

  20. Arrogance analysis of several typical pattern recognition classifiers

    NASA Astrophysics Data System (ADS)

    Jing, Chen; Xia, Shengping; Hu, Weidong

    2007-04-01

    Various kinds of classification methods have been developed. However, most of these classical methods, such as Back-Propagation (BP), Bayesian method, Support Vector Machine(SVM), Self-Organizing Map (SOM) are arrogant. A so-called arrogance, for a human, means that his decision, which even is a mistake, overstates his actual experience. Accordingly, we say that he is a arrogant if he frequently makes arrogant decisions. Likewise, some classical pattern classifiers represent the similar characteristic of arrogance. Given an input feature vector, we say a classifier is arrogant in its classification if its veracity is high yet its experience is low. Typically, for a new sample which is distinguishable from original training samples, traditional classifiers recognize it as one of the known targets. Clearly, arrogance in classification is an undesirable attribute. Conversely, a classifier is non-arrogant in its classification if there is a reasonable balance between its veracity and its experience. Inquisitiveness is, in many ways, the opposite of arrogance. In nature, inquisitiveness is an eagerness for knowledge characterized by the drive to question, to seek a deeper understanding. The human capacity to doubt present beliefs allows us to acquire new experiences and to learn from our mistakes. Within the discrete world of computers, inquisitive pattern recognition is the constructive investigation and exploitation of conflict in information. Thus, we quantify this balance and discuss new techniques that will detect arrogance in a classifier.

  1. Correction of motion artifacts and serial correlations for real-time functional near-infrared spectroscopy

    PubMed Central

    Barker, Jeffrey W.; Rosso, Andrea L.; Sparto, Patrick J.; Huppert, Theodore J.

    2016-01-01

    Abstract. Functional near-infrared spectroscopy (fNIRS) is a relatively low-cost, portable, noninvasive neuroimaging technique for measuring task-evoked hemodynamic changes in the brain. Because fNIRS can be applied to a wide range of populations, such as children or infants, and under a variety of study conditions, including those involving physical movement, gait, or balance, fNIRS data are often confounded by motion artifacts. Furthermore, the high sampling rate of fNIRS leads to high temporal autocorrelation due to systemic physiology. These two factors can reduce the sensitivity and specificity of detecting hemodynamic changes. In a previous work, we showed that these factors could be mitigated by autoregressive-based prewhitening followed by the application of an iterative reweighted least squares algorithm offline. This current work extends these same ideas to real-time analysis of brain signals by modifying the linear Kalman filter, resulting in an algorithm for online estimation that is robust to systemic physiology and motion artifacts. We evaluated the performance of the proposed method via simulations of evoked hemodynamics that were added to experimental resting-state data, which provided realistic fNIRS noise. Last, we applied the method post hoc to data from a standing balance task. Overall, the new method showed good agreement with the analogous offline algorithm, in which both methods outperformed ordinary least squares methods. PMID:27226974

  2. Feasibility Study of Radiometry for Airborne Detection of Aviation Hazards

    NASA Technical Reports Server (NTRS)

    Gimmestad, Gary G.; Papanicolopoulos, Chris D.; Richards, Mark A.; Sherman, Donald L.; West, Leanne L.; Johnson, James W. (Technical Monitor)

    2001-01-01

    Radiometric sensors for aviation hazards have the potential for widespread and inexpensive deployment on aircraft. This report contains discussions of three aviation hazards - icing, turbulence, and volcanic ash - as well as candidate radiometric detection techniques for each hazard. Dual-polarization microwave radiometry is the only viable radiometric technique for detection of icing conditions, but more research will be required to assess its usefulness to the aviation community. Passive infrared techniques are being developed for detection of turbulence and volcanic ash by researchers in this country and also in Australia. Further investigation of the infrared airborne radiometric hazard detection approaches will also be required in order to develop reliable detection/discrimination techniques. This report includes a description of a commercial hyperspectral imager for investigating the infrared detection techniques for turbulence and volcanic ash.

  3. On the predictability of protein database search complexity and its relevance to optimization of distributed searches.

    PubMed

    Deciu, Cosmin; Sun, Jun; Wall, Mark A

    2007-09-01

    We discuss several aspects related to load balancing of database search jobs in a distributed computing environment, such as Linux cluster. Load balancing is a technique for making the most of multiple computational resources, which is particularly relevant in environments in which the usage of such resources is very high. The particular case of the Sequest program is considered here, but the general methodology should apply to any similar database search program. We show how the runtimes for Sequest searches of tandem mass spectral data can be predicted from profiles of previous representative searches, and how this information can be used for better load balancing of novel data. A well-known heuristic load balancing method is shown to be applicable to this problem, and its performance is analyzed for a variety of search parameters.

  4. Optimal case-control matching in practice.

    PubMed

    Cologne, J B; Shibata, Y

    1995-05-01

    We illustrate modern matching techniques and discuss practical issues in defining the closeness of matching for retrospective case-control designs (in which the pool of subjects already exists when the study commences). We empirically compare matching on a balancing score, analogous to the propensity score for treated/control matching, with matching on a weighted distance measure. Although both methods in principle produce balance between cases and controls in the marginal distributions of the matching covariates, the weighted distance measure provides better balance in practice because the balancing score can be poorly estimated. We emphasize the use of optimal matching based on efficient network algorithms. An illustration is based on the design of a case-control study of hepatitis B virus infection as a possible confounder and/or effect modifier of radiation-related primary liver cancer in atomic bomb survivors.

  5. Response of an aerosol mass spectrometer to organonitrates and organosulfates and implications for atmospheric chemistry

    PubMed Central

    Farmer, D. K.; Matsunaga, A.; Docherty, K. S.; Surratt, J. D.; Seinfeld, J. H.; Ziemann, P. J.; Jimenez, J. L.

    2010-01-01

    Organonitrates (ON) are important products of gas-phase oxidation of volatile organic compounds in the troposphere; some models predict, and laboratory studies show, the formation of large, multifunctional ON with vapor pressures low enough to partition to the particle phase. Organosulfates (OS) have also been recently detected in secondary organic aerosol. Despite their potential importance, ON and OS remain a nearly unexplored aspect of atmospheric chemistry because few studies have quantified particulate ON or OS in ambient air. We report the response of a high-resolution time-of-flight aerosol mass spectrometer (AMS) to aerosol ON and OS standards and mixtures. We quantify the potentially substantial underestimation of organic aerosol O/C, commonly used as a metric for aging, and N/C. Most of the ON-nitrogen appears as ions in the AMS, which are typically dominated by inorganic nitrate. Minor organonitrogen ions are observed although their identity and intensity vary between standards. We evaluate the potential for using fragment ratios, organonitrogen ions, ions, the ammonium balance of the nominally inorganic ions, and comparison to ion-chromatography instruments to constrain the concentrations of ON for ambient datasets, and apply these techniques to a field study in Riverside, CA. OS manifests as separate organic and sulfate components in the AMS with minimal organosulfur fragments and little difference in fragmentation from inorganic sulfate. The low thermal stability of ON and OS likely causes similar detection difficulties for other aerosol mass spectrometers using vaporization and/or ionization techniques with similar or larger energy, which has likely led to an underappreciation of these species. PMID:20194777

  6. A Survey on Anomaly Based Host Intrusion Detection System

    NASA Astrophysics Data System (ADS)

    Jose, Shijoe; Malathi, D.; Reddy, Bharath; Jayaseeli, Dorathi

    2018-04-01

    An intrusion detection system (IDS) is hardware, software or a combination of two, for monitoring network or system activities to detect malicious signs. In computer security, designing a robust intrusion detection system is one of the most fundamental and important problems. The primary function of system is detecting intrusion and gives alerts when user tries to intrusion on timely manner. In these techniques when IDS find out intrusion it will send alert massage to the system administrator. Anomaly detection is an important problem that has been researched within diverse research areas and application domains. This survey tries to provide a structured and comprehensive overview of the research on anomaly detection. From the existing anomaly detection techniques, each technique has relative strengths and weaknesses. The current state of the experiment practice in the field of anomaly-based intrusion detection is reviewed and survey recent studies in this. This survey provides a study of existing anomaly detection techniques, and how the techniques used in one area can be applied in another application domain.

  7. Balancing Between Aging and Cancer: Molecular Genetics Meets Traditional Chinese Medicine.

    PubMed

    Liu, Jing; Peng, Lei; Huang, Wenhui; Li, Zhiming; Pan, Jun; Sang, Lei; Lu, Siqian; Zhang, Jihong; Li, Wanyi; Luo, Ying

    2017-09-01

    The biological consequences of cellular senescence and immortalization in aging and cancer are in conflict. Organisms have developed common cellular signaling pathways and surveillance mechanisms to control the processing of aging against tumorigenesis. The imbalance of any signals involved in this process may result in either premature aging or tumorigenesis and reduce the life span of the organism. In contrast, the balance between aging and tumorigenesis at a higher level (homeostatic-balance) may benefit the organism with tumor-free longevity. The focus of this perspective is to review the literature on the balance between "Yin" and "Yang" in traditional Chinese medicine. Modern cellular and molecular techniques now permit a more robust system to screen herbs in traditional Chinese medicine for their activity in balancing aging and tumorigenesis. The understanding of the crosstalk between aging and tumorigenesis and new perspectives on the application of Chinese medicine might shed light on anti-aging and tumor-free strategies. J. Cell. Biochem. 118: 2581-2586, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. An efficient algorithm using matrix methods to solve wind tunnel force-balance equations

    NASA Technical Reports Server (NTRS)

    Smith, D. L.

    1972-01-01

    An iterative procedure applying matrix methods to accomplish an efficient algorithm for automatic computer reduction of wind-tunnel force-balance data has been developed. Balance equations are expressed in a matrix form that is convenient for storing balance sensitivities and interaction coefficient values for online or offline batch data reduction. The convergence of the iterative values to a unique solution of this system of equations is investigated, and it is shown that for balances which satisfy the criteria discussed, this type of solution does occur. Methods for making sensitivity adjustments and initial load effect considerations in wind-tunnel applications are also discussed, and the logic for determining the convergence accuracy limits for the iterative solution is given. This more efficient data reduction program is compared with the technique presently in use at the NASA Langley Research Center, and computational times on the order of one-third or less are demonstrated by use of this new program.

  9. Average discharge, perennial flow initiation, and channel initiation - small southern Appalachian basins

    Treesearch

    B. Lane Rivenbark; C. Rhett Jackson

    2004-01-01

    Regional average evapotranspiration estimates developed by water balance techniques are frequently used to estimate average discharge in ungaged strttams. However, the lower stream size range for the validity of these techniques has not been explored. Flow records were collected and evaluated for 16 small streams in the Southern Appalachians to test whether the...

  10. TECHNIQUES FOR ACHIEVING RACIALLY DESEGREGATED, SUPERIOR QUALITY EDUCATION IN THE PUBLIC SCHOOLS OF CHICAGO, ILLINOIS.

    ERIC Educational Resources Information Center

    WEINBERG, MEYER

    THIS PAPER OUTLINES 12 TECHNIQUES FOR INTEGRATING THE SCHOOLS IN CHICAGO, ILLINOIS, OVER A 2-YEAR PERIOD. FIRST, TO USE SCHOOL SPACE MORE EQUITABLY, THERE SHOULD BE MANDATORY TRANSFER ASSIGNMENTS FOR BETTER RACIAL BALANCE, AND TRANSPORTATION SHOULD BE PAID FOR BY THE SCHOOL BOARD. SUCH A TRANSFER PLAN WOULD RELIEVE OVERCROWDING AND…

  11. Promising Behavior Change Techniques in a Multicomponent Intervention to Reduce Concerns about Falls in Old Age: A Delphi Study

    ERIC Educational Resources Information Center

    Vestjens, Lotte; Kempen, Gertrudis I. J. M.; Crutzen, Rik; Kok, Gerjo; Zijlstra, G. A. Rixt

    2015-01-01

    Complex behavior change interventions need evidence regarding the effectiveness of individual components to understand how these interventions work. The objective of this study was to identify the least and most promising behavior change techniques (BCTs) within the Dutch intervention "A Matter of Balance" (AMB-NL) aimed at concerns…

  12. Measurement techniques investigated for detection of hydrogen chloride gas in ambient air

    NASA Technical Reports Server (NTRS)

    Gregory, G. L.

    1976-01-01

    Nine basic techniques are discussed, ranging from concentration (parts per million) to dosage only (parts per million-seconds) measurement techniques. Data for each technique include lower detection limit, response time, instrument status, and in some cases, specificity. Several techniques discussed can detect ambient hydrogen chloride concentrations below 1 part per million with a response time of seconds.

  13. The effect of transcranial direct current stimulation (tDCS) on locomotion and balance in patients with chronic stroke: study protocol for a randomised controlled trial.

    PubMed

    Geiger, M; Supiot, A; Zory, R; Aegerter, P; Pradon, D; Roche, N

    2017-10-23

    Following stroke, patients are often left with hemiparesis that reduces balance and gait capacity. A recent, non-invasive technique, transcranial direct current stimulation, can be used to modify cortical excitability when used in an anodal configuration. It also increases the excitability of spinal neuronal circuits involved in movement in healthy subjects. Many studies in patients with stroke have shown that this technique can improve motor, sensory and cognitive function. For example, anodal tDCS has been shown to improve motor performance of the lower limbs in patients with stroke, such as voluntary quadriceps strength, toe-pinch force and reaction time. Nevertheless, studies of motor function have been limited to simple tasks. Surprisingly, the effects of tDCS on the locomotion and balance of patients with chronic stroke have never been evaluated. In this study, we hypothesise that anodal tDCS will improve balance and gait parameters in patients with chronic stroke-related hemiparesis through its effects at cortical and spinal level. This is a prospective, randomised, placebo-controlled, double-blinded, single-centre, cross-over study over 36 months. Forty patients with chronic stroke will be included. Each patient will participate in three visits: an inclusion visit, and two visits during which they will all undergo either one 30-min session of transcranial direct current stimulation or one 30-min session of placebo stimulation in a randomised order. Evaluations will be carried out before, during and twice after stimulation. The primary outcome is the variability of the displacement of the centre of mass during gait and a static-balance task. Secondary outcomes include clinical and functional measures before and after stimulation. A three-dimensional gait analysis, and evaluation of static balance on a force platform will be also conducted before, during and after stimulation. These results should constitute a useful database to determine the aspects of complex motor function that are the most improved by transcranial direct current stimulation in patients with hemiparesis. It is the first essential step towards validating this technique as a treatment, coupled with task-oriented training. ClinicalTrials.gov, ID: NCT02134158 . First received on 18 December 2013; last updated on 14 September 2016. Other study ID numbers: P120135 / AOM12126, 2013-A00952-43.

  14. [Total and unicompartmental knee replacement. Patient-specific Instrumentation].

    PubMed

    Köster, G; Biró, C

    2016-04-01

    The objective of patient-specific instrumentation (PSI Zimmer®) technology is to optimize positioning and selection of components as well as surgical procedure in uni- and bicompartimental knee replacement. The article contains a description of the planning and surgical technique and evaluates the method based on own results and literature. Using MRI or CT scans a virtual 3D model of the joint is created in order to simulate and plan the implant positioning. According to these data, pin placement and/or cutting guides are produced, which enable the surgeon to transfer the planning to the surgical procedure. In a prospective comparative study 88 patients (44 per each of the two techniques) were operated by one surgeon receiving the same TKA using either MRI-based PSI or a conventional technique. The number of surgical trays, operating time, intraoperative changes and frontal alignment using a full leg x‑ray (70 cases) were compared. In 17 patients the method was applied with unicondylar knee replacement. Anatomical abnormalities could be detected preoperatively and considered during the operation. With PSI the number of trays could be reduced and predictability of the component size was more precise. Intraoperative changes became necessary only for distal femoral (25 %) and proximal tibial (36 %) resection and tibial rotation (40 %). Alignment was more precise in the PSI cases PSI using the applied technique proved to be practicable and reliable. The advantages of precise planning became obvious. Results concerning alignment are inconsistent in the literature. Soft tissue balancing has only been included in the technique to a limited degree so far. PSI is still in an early stage of development and further development opportunities should be exploited before final assessment.

  15. Career Planning in Harmony with Family Values and Needs

    NASA Astrophysics Data System (ADS)

    Dubey, Archana

    2008-03-01

    Balancing career and family! Balancing what you love and who you love!! It is such an attention getting topic. And yet, if you really think about it, people have been doing it for ages. What makes it challenging in today's world is the dual income families that throw off-balance of traditional style of balancing family and profession. Balancing family and career is not as difficult. The question is more meaningful when you ask how do you find the right balance, and in fact, what is the right balance? How do you know you are there? Happiness at home and self esteem due to work is genderless issue however, it is essentially talked more in the context of women. Some of the things that could be helpful in achieving the right balance, are time management, proper prioritization, asking for help, a caring family, friends, and most importantly colleagues. In the portfolio of professional passions, it is important to identify the areas that are conducive to possibilities of changing family needs, international families, spouse's career and job relocation, etc. So, the bottom line question is whether it is possible to find a right balance between family and career? I would submit to you that with passion, courage, open- mindedness, and proper career planning, it is definitely possible. We just need to utilize the same techniques in choosing and sustaining the right balance that we use in identifying research topics and executing it. This discussion will look into further details of the challenges of balancing family and career from the perspective of also an immigrant, and possible ways of overcoming them.

  16. Design of two wheel self balancing car

    NASA Astrophysics Data System (ADS)

    He, Chun-hong; Ren, Bin

    2018-02-01

    This paper proposes a design scheme of the two-wheel self-balancing dolly, the integration of the gyroscope and accelerometer MPU6050 constitutes the car position detection device.System selects 32-bit MCU stmicroelectronics company as the control core, completed the processing of sensor signals, the realization of the filtering algorithm, motion control and human-computer interaction. Produced and debugging in the whole system is completed, the car can realize the independent balance under the condition of no intervention. The introduction of a suitable amount of interference, the car can adjust quickly to recover and steady state. Through remote control car bluetooth module complete forward, backward, turn left and other basic action..

  17. Eddy current techniques for super duplex stainless steel characterization

    NASA Astrophysics Data System (ADS)

    Camerini, C.; Sacramento, R.; Areiza, M. C.; Rocha, A.; Santos, R.; Rebello, J. M.; Pereira, G.

    2015-08-01

    Super duplex stainless steel (SDSS) is a two-phase material where the microstructure consists of grains of ferrite (δ) and austenite (γ). SDSS exhibit an attractive combination of properties, such as: strength, toughness and stress corrosion cracking resistance. Nevertheless, SDSS attain these properties after a controlled solution heat treatment, leading to a similar volumetric fraction of δ and γ. Any further heat treatment, welding operation for example, can change the balance of the original phases, or may also lead to precipitation of a deleterious phase, such as sigma (σ). For these situations, the material corrosion resistance is severely impaired. In the present study, several SDSS samples with low σ phase content and non-balanced microstructure were intentionally obtained by thermally treating SDSS specimens. Electromagnetic techniques, conventional Eddy Current Testing (ECT) and Saturated Low Frequency Eddy Current (SLOFEC), were employed to characterize the SDSS samples. The results showed that ECT and SLOFEC are reliable techniques to evaluate σ phase presence in SDSS and can provide an estimation of the δ content.

  18. Change detection from remotely sensed images: From pixel-based to object-based approaches

    NASA Astrophysics Data System (ADS)

    Hussain, Masroor; Chen, Dongmei; Cheng, Angela; Wei, Hui; Stanley, David

    2013-06-01

    The appetite for up-to-date information about earth's surface is ever increasing, as such information provides a base for a large number of applications, including local, regional and global resources monitoring, land-cover and land-use change monitoring, and environmental studies. The data from remote sensing satellites provide opportunities to acquire information about land at varying resolutions and has been widely used for change detection studies. A large number of change detection methodologies and techniques, utilizing remotely sensed data, have been developed, and newer techniques are still emerging. This paper begins with a discussion of the traditionally pixel-based and (mostly) statistics-oriented change detection techniques which focus mainly on the spectral values and mostly ignore the spatial context. This is succeeded by a review of object-based change detection techniques. Finally there is a brief discussion of spatial data mining techniques in image processing and change detection from remote sensing data. The merits and issues of different techniques are compared. The importance of the exponential increase in the image data volume and multiple sensors and associated challenges on the development of change detection techniques are highlighted. With the wide use of very-high-resolution (VHR) remotely sensed images, object-based methods and data mining techniques may have more potential in change detection.

  19. Can excreted thiocyanate be used to detect cyanide exposure in live reef fish?

    PubMed Central

    Breen, Nancy E.; Andrade, Lawrence

    2018-01-01

    Cyanide fishing, where a solution of sodium or potassium cyanide is used to stun reef fish for easy capture for the marine aquarium and live fish food trades, continues to be pervasive despite being illegal in many countries and destructive to coral reef ecosystems. Currently, there is no easy, reliable and universally accepted method to detect if a fish has been exposed to cyanide during the capture process. A promising non-invasive technique for detecting thiocyanate ions, the metabolic byproduct excreted by exposed fish, has been reported in the literature. In an effort to validate this method, four cyanide exposure studies on Amphiprion ocellaris (common clownfish) were carried out over three years. Fish were either exposed to the same (25 ppm) or twice the concentration (50 ppm) as the previsouly published method. Over 100 water samples of fish exposed to cyanide were analyzed by reverse phase HPLC with a C30 column treated with polyethylene glycol and UV detector operating at 220 nm. No thiocyanate was detected beyond the analytical standards and positive controls prepared in seawater. As an alternate means of detecting thiocyanate, water samples and thiocyanate standards from these exposures were derivatized with monobromobimane (MBB) for LC-MS/MS analysis. Thiocyanate was detected in standards with concentrations as low as 0.6 μg/L and quantified to 1 μg/L, but thiocyanate could not be detected in any of the water samples from fish exposed to cyanide with this method either, confirming the HPLC results. Further, we calculated both the mass balance of thiocyanate and the resultant plausible dosage of cyanide from the data reported in the previously published method. These calculations, along with the known lethal dosage of cyanide, further suggests that the detection of thiocyanate in aquarium water is not a viable method for assessing fish exposure to cyanide. PMID:29847597

  20. First results on label-free detection of DNA and protein molecules using a novel integrated sensor technology based on gravimetric detection principles.

    PubMed

    Gabl, R; Feucht, H-D; Zeininger, H; Eckstein, G; Schreiter, M; Primig, R; Pitzer, D; Wersing, W

    2004-01-15

    A novel integrated bio-sensor technology based on thin-film bulk acoustic wave resonators on silicon is presented and the feasibility of detecting DNA and protein molecules proofed. The detection principle of these sensors is label-free and relies on a resonance frequency shift caused by mass loading of an acoustic resonator, a principle very well known from quartz crystal micro balances. Integrated ZnO bulk acoustic wave resonators with resonance frequencies around 2 GHz have been fabricated, employing an acoustic mirror for isolation from the silicon substrate. DNA oligos have been thiol-coupled to the gold electrode by on-wafer dispensing. In a further step, samples have either been hybridised or alternatively a protein has been coupled to the receptor. The measurement results show the new bio-sensor being capable of both, detecting proteins as well as the DNA hybridisation without using a label. Due to the substantially higher oscillation frequency, these sensors already show much higher sensitivity and resolution comparable to quartz crystal micro balances. The potential for these sensors and sensors arrays as well as technological challenges will be discussed in detail.

  1. Association of balance, strength, and power measures in young adults.

    PubMed

    Muehlbauer, Thomas; Gollhofer, Albert; Granacher, Urs

    2013-03-01

    The purpose of this study was to investigate the relationship between variables of static/dynamic balance, isometric strength, and power. Twenty-seven young healthy adults (mean age: 23 ± 4 years) performed measurements of static (unperturbed)/dynamic (perturbed) balance, isometric strength (i.e., maximal isometric torque [MIT]; rate of torque development [RTD] of the plantar flexor), and power (i.e., countermovement jump [CMJ] height and power). No significant associations were found between variables of static and dynamic balance (r = -0.090 to +0.329, p > 0.05) and between measures of static/dynamic balance and isometric strength (r = +0.041 to +0.387, p > 0.05) and static/dynamic balance and power (r = -0.076 to +0.218, p > 0.05). Significant positive correlations (r) were detected between variables of power and isometric strength ranging from +0.458 to +0.689 (p < 0.05). Furthermore, simple regression analyses revealed that a 10% increase in mean CMJ height (4.1 cm) was associated with 22.9 N·m and 128.4 N·m·s better MIT and RTD, respectively. The nonsignificant correlation between static and dynamic balance measures and between static/dynamic balance, isometric strength, and power variables implies that these capacities may be independent of each other and may have to be tested and trained complementarily.

  2. Virtual Reality-Based Center of Mass-Assisted Personalized Balance Training System

    PubMed Central

    Kumar, Deepesh; González, Alejandro; Das, Abhijit; Dutta, Anirban; Fraisse, Philippe; Hayashibe, Mitsuhiro; Lahiri, Uttama

    2018-01-01

    Poststroke hemiplegic patients often show altered weight distribution with balance disorders, increasing their risk of fall. Conventional balance training, though powerful, suffers from scarcity of trained therapists, frequent visits to clinics to get therapy, one-on-one therapy sessions, and monotony of repetitive exercise tasks. Thus, technology-assisted balance rehabilitation can be an alternative solution. Here, we chose virtual reality as a technology-based platform to develop motivating balance tasks. This platform was augmented with off-the-shelf available sensors such as Nintendo Wii balance board and Kinect to estimate one’s center of mass (CoM). The virtual reality-based CoM-assisted balance tasks (Virtual CoMBaT) was designed to be adaptive to one’s individualized weight-shifting capability quantified through CoM displacement. Participants were asked to interact with Virtual CoMBaT that offered tasks of varying challenge levels while adhering to ankle strategy for weight shifting. To facilitate the patients to use ankle strategy during weight-shifting, we designed a heel lift detection module. A usability study was carried out with 12 hemiplegic patients. Results indicate the potential of our system to contribute to improving one’s overall performance in balance-related tasks belonging to different difficulty levels. PMID:29359128

  3. The virtual time to contact in the evaluation of balance disorders and prediction of falls in people with multiple sclerosis.

    PubMed

    Cattaneo, Davide; Ferrarin, Maurizio; Jonsdottir, Johanna; Montesano, Angelo; Bove, Marco

    2012-01-01

    The purpose of the study was to compute Virtual Time to Contact (VTC) from stabilometric assessment to study balance impairments in people with multiple sclerosis (PwMS). To this purpose we assessed the ability of VTC to discriminate between balance skills of PwMS and healthy subjects (HS), among sensory conditions and between fallers and non fallers. VTC was calculated to characterize balance performance in 47 PwMS and 13 HS in four different sensory conditions during quiet standing. Main Outcome Measures were VTC, Number of falls, Berg Balance Scale and Dynamic Gait Index. The results showed that VTC was able to discriminate between PwMS and HS (p < 0.0001) and between challenging sensory conditions (p < 0.0001), no relevant information was added by VTC in the detection of subjects prone to falls. VTC provides unique information with respect to balance control because it takes into account the relationship between centre of mass (CoM) and the borders of base of support (BoS). VTC proved to be a valid descriptor of balance performance in PwMS highlighting balance disorders in this population of subjects, however models for falls prediction have to be improved.

  4. A New Load Residual Threshold Definition for the Evaluation of Wind Tunnel Strain-Gage Balance Data

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.; Volden, T.

    2016-01-01

    A new definition of a threshold for the detection of load residual outliers of wind tunnel strain-gage balance data was developed. The new threshold is defined as the product between the inverse of the absolute value of the primary gage sensitivity and an empirical limit of the electrical outputs of a strain{gage. The empirical limit of the outputs is either 2.5 microV/V for balance calibration or check load residuals. A reduced limit of 0.5 microV/V is recommended for the evaluation of differences between repeat load points because, by design, the calculation of these differences removes errors in the residuals that are associated with the regression analysis of the data itself. The definition of the new threshold and different methods for the determination of the primary gage sensitivity are discussed. In addition, calibration data of a six-component force balance and a five-component semi-span balance are used to illustrate the application of the proposed new threshold definition to different types of strain{gage balances. During the discussion of the force balance example it is also explained how the estimated maximum expected output of a balance gage can be used to better understand results of the application of the new threshold definition.

  5. Isola spinal instrumentation system for idiopathic scoliosis.

    PubMed

    Benli, I T; Akalin, S; Aydin, E; Baz, A; Citak, M; Kiş, M; Duman, E

    2001-01-01

    Since the definition of three-dimensional components of the scoliotic deformity, there have been important improvements in the surgical treatment of the problem. A derotation maneuver was proposed as a treatment option with CD instrumentation, but the reports of imbalance and decompensation with this system repopularized sublaminar wiring and translation as a corrective maneuver. Isola spinal instrumentation is one of the modern systems that utilizes vertebral translation instead of rod rotation. This study analyzes the results of 24 patients with idiopathic scoliosis who had been followed up for at least 2 years, and were surgically treated with titanium Isola Spinal Instrumentation in the Department of Orthopaedics and Traumatology, Ankara Social Security Hospital. Patients were grouped according to the King-Moe classification. Patients with type III, IV or V curves received only posterior instrumentation while this procedure followed anterior release and discectomy in the same session in patients with type I or II curves. A translation maneuver was utilized in the correction of scoliotic curves using the cantilever technique, either alone or supplemented by sublaminar wiring with Songer multifilament titanium cables. This study aimed to elucidate the effects of this technique in the frontal and sagittal plane curves and the trunk balance. The balance was analyzed clinically and radiologically by measurement of the lateral trunk shift (LT), shift of stable vertebra (SS), and shift of head (SH) in vertebral units (VU). The postoperative correction was significant in the frontal plane for all types of curves (p < 0.05). The postoperative correction was 80.9% +/- 9.5% in type III curves. Overall, the mean Cobb angle of the major curve value in the frontal plane was 66.9 degrees +/- 18.8 degrees, and it was corrected by 62.8% +/- 20.1%. The correction loss of Cobb angles in the frontal plane was 5.4 degrees +/- 5.5 degrees at the last follow-up visit. A normal physiologic thoracic contour (30 degrees - 50 degrees) was achieved in 83.3% of the patients and normal lumbar contour (40 degrees - 60 degrees) in 66.7% of the patients in the sagittal plane. The correction was found to be significant in all balance values (p < 0.05). The postoperative correction in LT values correlated with the correction of the Cobb angle values in the frontal plane. All patients had complete balance (SH: 0 VU and SS: 0 VU) or balanced curves (0 VU < SH, SS < 0.5 VU).Finally, the study concluded that the translation maneuver, especially when used with the cantilever technique, resulted in high correction rates in the frontal plane. Additionally, the technique was also successful in obtaining normal sagittal contours and correcting balance values.

  6. War by Other Means. Building Complete and Balanced Capabilities for Counterinsurgency

    DTIC Science & Technology

    2008-01-01

    than familiar (Type I and II) ones. Iraq and Afghanistan show how jihadist ideas (e.g., the appeal for holy war) and techniques (e.g., suicide bombing...cannot finish off this familiar and contained sort of politi- cal insurgency, how can it stop more complex and sprawling ones that borrow added... familiar with the pop- 184 War by Other Means: Building Complete and Balanced COIN Capabilities ulation and have a better understanding of what messages

  7. Analysis techniques for momentum transport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, S.D.

    1991-08-01

    This report discusses the following topics on momentum analysis in tokamaks and stellarators: the momentum balance equation; deposition of torque by neutral beams; effects of toroidal rotation; and experimental observations. (LSP)

  8. Validation of balance-quality assessment using a modified bathroom scale.

    PubMed

    Hewson, D J; Duchêne, J; Hogrel, J-Y

    2015-02-01

    The balance quality tester (BQT), based on a standard electronic bathroom scale has been developed in order to assess balance quality. The BQT includes automatic detection of the person to be tested by means of an infrared detector and bluetooth communication capability for remote assessment when linked to a long-distance communication device such as a mobile phone. The BQT was compared to a standard force plate for validity and agreement. The two most widely reported parameters in balance literature, the area of the centre of pressure (COP) displacement and the velocity of the COP displacement, were compared for 12 subjects, each of whom was tested on ten occasions on each of the 2 days. No significant differences were observed between the BQT and the force plate for either of the two parameters. In addition a high level of agreement was observed between both devices. The BQT is a valid device for remote assessment of balance quality, and could provide a useful tool for long-term monitoring of people with balance problems, particularly during home monitoring.

  9. Indirect addressing and load balancing for faster solution to Mandelbrot Set on SIMD architectures

    NASA Technical Reports Server (NTRS)

    Tomboulian, Sherryl

    1989-01-01

    SIMD computers with local indirect addressing allow programs to have queues and buffers, making certain kinds of problems much more efficient. Examined here are a class of problems characterized by computations on data points where the computation is identical, but the convergence rate is data dependent. Normally, in this situation, the algorithm time is governed by the maximum number of iterations required by each point. Using indirect addressing allows a processor to proceed to the next data point when it is done, reducing the overall number of iterations required to approach the mean convergence rate when a sufficiently large problem set is solved. Load balancing techniques can be applied for additional performance improvement. Simulations of this technique applied to solving Mandelbrot Sets indicate significant performance gains.

  10. Determination of the spin and recovery characteristics of a typical low-wing general aviation design

    NASA Technical Reports Server (NTRS)

    Tischler, M. B.; Barlow, J. B.

    1980-01-01

    The equilibrium spin technique implemented in a graphical form for obtaining spin and recovery characteristics from rotary balance data is outlined. Results of its application to recent rotary balance tests of the NASA Low-Wing General Aviation Aircraft are discussed. The present results, which are an extension of previously published findings, indicate the ability of the equilibrium method to accurately evaluate spin modes and recovery control effectiveness. A comparison of the calculated results with available spin tunnel and full scale findings is presented. The technique is suitable for preliminary design applications as determined from the available results and data base requirements. A full discussion of implementation considerations and a summary of the results obtained from this method to date are presented.

  11. Fingerprinting Software Defined Networks and Controllers

    DTIC Science & Technology

    2015-03-01

    24 2.5.3 Intrusion Prevention System with SDN . . . . . . . . . . . . . . . 25 2.5.4 Modular Security Services...Control Message Protocol IDS Intrusion Detection System IPS Intrusion Prevention System ISP Internet Service Provider LLDP Link Layer Discovery Protocol...layer functions (e.g., web proxies, firewalls, intrusion detection/prevention, load balancers, etc.). The increase in switch capabilities combined

  12. Silicon photonic integrated circuit swept-source optical coherence tomography receiver with dual polarization, dual balanced, in-phase and quadrature detection.

    PubMed

    Wang, Zhao; Lee, Hsiang-Chieh; Vermeulen, Diedrik; Chen, Long; Nielsen, Torben; Park, Seo Yeon; Ghaemi, Allan; Swanson, Eric; Doerr, Chris; Fujimoto, James

    2015-07-01

    Optical coherence tomography (OCT) is a widely used three-dimensional (3D) optical imaging method with many biomedical and non-medical applications. Miniaturization, cost reduction, and increased functionality of OCT systems will be critical for future emerging clinical applications. We present a silicon photonic integrated circuit swept-source OCT (SS-OCT) coherent receiver with dual polarization, dual balanced, in-phase and quadrature (IQ) detection. We demonstrate multiple functional capabilities of IQ polarization resolved detection including: complex-conjugate suppressed full-range OCT, polarization diversity detection, and polarization-sensitive OCT. To our knowledge, this is the first demonstration of a silicon photonic integrated receiver for OCT. The integrated coherent receiver provides a miniaturized, low-cost solution for SS-OCT, and is also a key step towards a fully integrated high speed SS-OCT system with good performance and multi-functional capabilities. With further performance improvement and cost reduction, photonic integrated technology promises to greatly increase penetration of OCT systems in existing applications and enable new applications.

  13. Silicon photonic integrated circuit swept-source optical coherence tomography receiver with dual polarization, dual balanced, in-phase and quadrature detection

    PubMed Central

    Wang, Zhao; Lee, Hsiang-Chieh; Vermeulen, Diedrik; Chen, Long; Nielsen, Torben; Park, Seo Yeon; Ghaemi, Allan; Swanson, Eric; Doerr, Chris; Fujimoto, James

    2015-01-01

    Optical coherence tomography (OCT) is a widely used three-dimensional (3D) optical imaging method with many biomedical and non-medical applications. Miniaturization, cost reduction, and increased functionality of OCT systems will be critical for future emerging clinical applications. We present a silicon photonic integrated circuit swept-source OCT (SS-OCT) coherent receiver with dual polarization, dual balanced, in-phase and quadrature (IQ) detection. We demonstrate multiple functional capabilities of IQ polarization resolved detection including: complex-conjugate suppressed full-range OCT, polarization diversity detection, and polarization-sensitive OCT. To our knowledge, this is the first demonstration of a silicon photonic integrated receiver for OCT. The integrated coherent receiver provides a miniaturized, low-cost solution for SS-OCT, and is also a key step towards a fully integrated high speed SS-OCT system with good performance and multi-functional capabilities. With further performance improvement and cost reduction, photonic integrated technology promises to greatly increase penetration of OCT systems in existing applications and enable new applications. PMID:26203382

  14. Load Balancing in Multi Cloud Computing Environment with Genetic Algorithm

    NASA Astrophysics Data System (ADS)

    Vhansure, Fularani; Deshmukh, Apurva; Sumathy, S.

    2017-11-01

    Cloud is a pool of resources that is available on pay per use model. It provides services to the user which is increasing rapidly. Load balancing is an issue because it cannot handle so many requests at a time. It is also known as NP complete problem. In traditional system the functions consist of various parameter values to maximise it in order to achieve best optimal individualsolutions. Challenge is when there are many parameters of solutionsin the system space. Another challenge is to optimize the function which is much more complex. In this paper, various techniques to handle load balancing virtually (VM) as well as physically (nodes) using genetic algorithm is discussed.

  15. Unsupervised Spatial, Temporal and Relational Models for Social Processes

    DTIC Science & Technology

    2012-02-01

    Andrej Mrvar . A partitioning approach to structural balance. Social Networks, 18(2):149 – 168, 1996 . [37] Thi V. Duong, Hung H. Bui, Dinh Q. Phung, and...partitioning provided by Doreian and Mrvar [36], who demonstrate that there was increasing evidence over time that 62 CHAPTER 4. COMMUNITY DETECTION this...foursome was a genuine group. Doreian and Mrvar used a block modeling approach optimiz- ing structural balance, a measure of cohesion incorporating

  16. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dubey, P. K., E-mail: premkdubey@gmail.com; Kumar, Yudhisther; Gupta, Reeta

    2014-05-15

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occursmore » at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.« less

  17. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    NASA Astrophysics Data System (ADS)

    Dubey, P. K.; Kumar, Yudhisther; Gupta, Reeta; Jain, Anshul; Gohiya, Chandrashekhar

    2014-05-01

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.

  18. Ultra-trace level determination of diquat and paraquat residues in surface and drinking water using ion-pair liquid chromatography with tandem mass spectrometry: a comparison of direct injection and solid-phase extraction methods.

    PubMed

    Oh, Jin-Aa; Lee, Jun-Bae; Lee, Soo-Hyung; Shin, Ho-Sang

    2014-10-01

    Direct injection and solid-phase extraction methods for the determination of diquat and paraquat in surface and drinking water were developed using liquid chromatography with tandem mass spectrometry. The signal intensities of analytes based on six ion-pairing reagents were compared with each other, and 12.5 mM nonafluoropentanoic acid was selected as the best suited amongst them. A clean-up method was developed using Oasis hydrophilic-lipophilic balance; this was compared to the direct injection method, with respect to limits of detection, interference, precision, and accuracy. Limits of quantification of diquat and paraquat were 0.03 and 0.01 μg/L using the direct injection method, and 0.002 and 0.001 μg/L using the hydrophilic-lipophilic balance method. When the hydrophilic-lipophilic balance method was used to analyze target compounds in 114 surface water and 30 drinking water samples, paraquat and diquat were detected within a concentration range of 0.001-0.12 and 0.002-0.038 μg/L in surface water, respectively. When the direct injection method was used to analyze target compounds in the same samples, the detected concentrations of paraquat and diquat were within 25% in samples being >0.015 μg/L using the hydrophilic-lipophilic balance method. The liquid chromatography with tandem mass spectrometry method using direct injection can thus be used for routine monitoring of paraquat and diquat in surface and drinking water. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Searches for continuous gravitational waves from Scorpius X-1 and XTE J1751-305 in LIGO's sixth science run

    NASA Astrophysics Data System (ADS)

    Meadors, G. D.; Goetz, E.; Riles, K.; Creighton, T.; Robinet, F.

    2017-02-01

    Scorpius X-1 (Sco X-1) and x-ray transient XTE J1751-305 are low-mass x-ray binaries (LMXBs) that may emit continuous gravitational waves detectable in the band of ground-based interferometric observatories. Neutron stars in LMXBs could reach a torque-balance steady-state equilibrium in which angular momentum addition from infalling matter from the binary companion is balanced by angular momentum loss, conceivably due to gravitational-wave emission. Torque balance predicts a scale for detectable gravitational-wave strain based on observed x-ray flux. This paper describes a search for Sco X-1 and XTE J1751-305 in LIGO science run 6 data using the TwoSpect algorithm, based on searching for orbital modulations in the frequency domain. While no detections are claimed, upper limits on continuous gravitational-wave emission from Sco X-1 are obtained, spanning gravitational-wave frequencies from 40 to 2040 Hz and projected semimajor axes from 0.90 to 1.98 light-seconds. These upper limits are injection validated, equal any previous set in initial LIGO data, and extend over a broader parameter range. At optimal strain sensitivity, achieved at 165 Hz, the 95% confidence level random-polarization upper limit on dimensionless strain h0 is approximately 1.8 ×10-24. The closest approach to the torque-balance limit, within a factor of 27, is also at 165 Hz. Upper limits are set in particular narrow frequency bands of interest for J1751-305. These are the first upper limits known to date on r -mode emission from this XTE source. The TwoSpect method will be used in upcoming searches of Advanced LIGO and Virgo data.

  20. Life expectancy and the value of early detection.

    PubMed

    Howard, David H

    2005-09-01

    This paper presents a model of the benefits and costs of early detection of asymptomatic disease as they vary by age. The benefits of early detection tend toward zero as the risk of death from competing causes increases. Costs per detected case also decline with age, assuming that disease incidence rises with age, but are always strictly positive. On balance, there is always an age limit beyond which the costs associated with early detection outweigh the benefits. Application of the model to prostate cancer screening suggests that early detection above age 70 or so is not cost-effective.

Top