Ball and Socket Ankle: Mechanism and Computational Evidence of Concept.
Jastifer, James R; Gustafson, Peter A; Labomascus, Aaron; Snoap, Tyler
The ball and socket ankle joint is a morphologically abnormal joint characterized by rounding of the articular surface of the talus. Other than anecdotal observation, little evidence has been presented to describe the development of this deformity. The purpose of the present study was to review ankle and subtalar joint mechanics and to kinematically examine the functional combination of these joints as a mechanism of the ball and socket ankle deformity. We reviewed functional representations of the ankle joint, subtalar joint, and ball and socket ankle deformity. A computational study of joint kinematics was then performed using a 3-dimensional model derived from a computed tomography scan of a ball and socket deformity. The joint kinematics were captured by creating a "virtual map" of the combined kinematics of the ankle and subtalar joints in the respective models. The ball and socket ankle deformity produces functionally similar kinematics to a combination of the ankle and subtalar joints. The findings of the present study support the notion that a possible cause of the ball and socket deformity is bony adaptation that compensates for a functional deficit of the ankle and subtalar joints. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Aperlo, P. J. A.; Buck, P. A.; Weldon, V. A.
1981-01-01
In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.
Improved Ball-and-Socket Docking Mechanism
NASA Technical Reports Server (NTRS)
Cloyd, Richard; Bryan, Tom
2004-01-01
A proposed docking mechanism would form a ball-and-socket joint in the docked condition. The mechanism could tolerate significant initial misalignment because it would include an alignment cone that would guide the ball into the socket. Like other ball-and-socket joints, the joint would have three rotational degrees of freedom. This docking mechanism would be a successor to the one described in Passive Capture Joint With Three Degrees of Freedom (MFS-31146), NASA Tech Briefs, Vol. 22, No. 7 (July 1998), page 65. It would contain most of the components of the prior mechanism, plus some additional components that would expand its capabilities.
21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.
Code of Federal Regulations, 2012 CFR
2012-04-01
...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...
21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.
Code of Federal Regulations, 2011 CFR
2011-04-01
...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...
21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.
Code of Federal Regulations, 2013 CFR
2013-04-01
...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...
21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.
Code of Federal Regulations, 2014 CFR
2014-04-01
...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...
Ball-and-Socket Joint Can Be Disassembled
NASA Technical Reports Server (NTRS)
Totah, R. S.
1982-01-01
Ball-and-socket joint originally developed for construction of large platforms in zero g could be used in such Earth-based temporary structures as scaffolding, camping equipment, tent posts, trade shows and displays. New joint consists of a socket mounted on central hub or union and ball-ended bolt or fitting mounted at end of a column or any structural member. Unit is self-contained, requires no loose hardware and is engaged or disengaged without tools manually, or remotely by a manipulator.
... end of the femur, which fits in a socket in the pelvis. Your hip is known as a ball-and-socket joint. This is because you have a ball ... of your femur, and it fits into a socket in your pelvis. This makes your hips very ...
Birk, Stephanie; Brase, Christoph; Hornung, Joachim
2014-08-01
In the further development of alloplastic prostheses for use in middle ear surgery, the Dresden and Cologne University Hospitals, working together with a company, introduced a new partial ossicular replacement prosthesis in 2011. The ball-and-socket joint between the prosthesis and the shaft mimics the natural articulations between the malleus and incus and between the incus and stapes, allowing reaction to movements of the tympanic membrane graft, particularly during the healing process. Retrospective evaluation To reconstruct sound conduction as part of a type III tympanoplasty, partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft was implanted in 60 patients, with other standard partial ossicular replacement prosthesis implanted in 40 patients and 64 patients. Pure-tone audiometry was carried out, on average, 19 and 213 days after surgery. Results of the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft were compared with those of the standard prostheses. Early measurements showed a mean improvement of 3.3 dB in the air-bone gap (ABG) with the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft, giving similar results than the standard implants (6.6 and 6.0 dB, respectively), but the differences were not statistically significant. Later measurements showed a statistically significant improvement in the mean ABG, 11.5 dB, compared with 4.4 dB for one of the standard partial ossicular replacement prosthesis and a tendency of better results to 6.9 dB of the other standard prosthesis. In our patients, we achieved similarly good audiometric results to those already published for the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft. Intraoperative fixation posed no problems, and the postoperative complication rate was low.
Passive Capture Joint with Three Degrees of Freedom
NASA Technical Reports Server (NTRS)
Cloyd, Richard A. (Inventor); Weddendorf, Bruce (Inventor)
2001-01-01
A passive capture joint with three degrees of freedom is presented wherein two structural elements are joined together solely by moving the two elements into position, and which when joined together have rotation in all three axes. The inventive apparatus is comprised of two halves: (1) a joint ball mounted on a stem as in a common trailer hitch, and; (2) a socket. The socket consists of a base having an exterior wall and forming an interior chamber, the chamber having a top end and a bottom end, and an interior wall. The chamber is open at the top end, and forms a spherical cup at the bottom end. The socket base's interior chamber is sized to accept the joint ball. The base also forms at least one bore at an acute angle away from the interior chamber's open end. The bores have a first opening in the interior wall of the chamber, and a second opening in the exterior wall of the base. Retaining balls sized to fit within the bores, but to only partially pass through the first opening, are moveably housed within the bores. The retaining balls are moveably held in the first opening by a compression spring housed in the bore. As the joint ball is inserted in the chamber it forces the retaining balls back into the bore until the equator of the joint ball passes. Because the bore is at an acute angle to the chamber the joint ball cannot exit the chamber without the joint being unlocked. The joint is unlocked by rotating a locking ring which encircles the base and covers the second opening. The locking ring has a radial slot for each retaining ball, disposed angularly from the base, and sized to allow passage of the retaining ball in the radial direction when the locking ring is rotated to align the radial slot with the second opening.
Normalization of load and clearance effects in ball-in-socket-like replacements.
Ciavarella, M; Strozzi, A; Baldini, A; Giacopini, M
2007-08-01
A normalizing loading parameter useful in summarising the mechanical response of plane pin-in-plate-like contacts is extended to axisymmetric ball-in-socket-like contacts. An example addressing a compliant layered artificial hip joint is presented, and the usefulness of the normalizing loading parameter is evidenced.
Low-Friction, High-Stiffness Joint for Uniaxial Load Cell
NASA Technical Reports Server (NTRS)
Lewis, James L.; Le, Thang; Carroll, Monty B.
2007-01-01
A universal-joint assembly has been devised for transferring axial tension or compression to a load cell. To maximize measurement accuracy, the assembly is required to minimize any moments and non-axial forces on the load cell and to exhibit little or no hysteresis. The requirement to minimize hysteresis translates to a requirement to maximize axial stiffness (including minimizing backlash) and a simultaneous requirement to minimize friction. In practice, these are competing requirements, encountered repeatedly in efforts to design universal joints. Often, universal-joint designs represent compromises between these requirements. The improved universal-joint assembly contains two universal joints, each containing two adjustable pairs of angular-contact ball bearings. One might be tempted to ask why one could not use simple ball-and-socket joints rather than something as complex as universal joints containing adjustable pairs of angularcontact ball bearings. The answer is that ball-and-socket joints do not offer sufficient latitude to trade stiffness versus friction: the inevitable result of an attempt to make such a trade in a ball-and-socket joint is either too much backlash or too much friction. The universal joints are located at opposite ends of an axial subassembly that contains the load cell. The axial subassembly includes an axial shaft, an axial housing, and a fifth adjustable pair of angular-contact ball bearings that allows rotation of the axial housing relative to the shaft. The preload on each pair of angular-contact ball bearings can be adjusted to obtain the required stiffness with minimal friction, tailored for a specific application. The universal joint at each end affords two degrees of freedom, allowing only axial force to reach the load cell regardless of application of moments and non-axial forces. The rotational joint on the axial subassembly affords a fifth degree of freedom, preventing application of a torsion load to the load cell.
Ernstbrunner, L; Werthel, J-D; Hatta, T; Thoreson, A R; Resch, H; An, K-N; Moroder, P
2016-10-01
The bony shoulder stability ratio (BSSR) allows for quantification of the bony stabilisers in vivo. We aimed to biomechanically validate the BSSR, determine whether joint incongruence affects the stability ratio (SR) of a shoulder model, and determine the correct parameters (glenoid concavity versus humeral head radius) for calculation of the BSSR in vivo. Four polyethylene balls (radii: 19.1 mm to 38.1 mm) were used to mould four fitting sockets in four different depths (3.2 mm to 19.1mm). The SR was measured in biomechanical congruent and incongruent experimental series. The experimental SR of a congruent system was compared with the calculated SR based on the BSSR approach. Differences in SR between congruent and incongruent experimental conditions were quantified. Finally, the experimental SR was compared with either calculated SR based on the socket concavity or plastic ball radius. The experimental SR is comparable with the calculated SR (mean difference 10%, sd 8%; relative values). The experimental incongruence study observed almost no differences (2%, sd 2%). The calculated SR on the basis of the socket concavity radius is superior in predicting the experimental SR (mean difference 10%, sd 9%) compared with the calculated SR based on the plastic ball radius (mean difference 42%, sd 55%). The present biomechanical investigation confirmed the validity of the BSSR. Incongruence has no significant effect on the SR of a shoulder model. In the event of an incongruent system, the calculation of the BSSR on the basis of the glenoid concavity radius is recommended.Cite this article: L. Ernstbrunner, J-D. Werthel, T. Hatta, A. R. Thoreson, H. Resch, K-N. An, P. Moroder. Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic 'ball-and-socket' joint model. Bone Joint Res 2016;5:453-460. DOI: 10.1302/2046-3758.510.BJR-2016-0078.R1. © 2016 Ernstbrunner et al.
Corrosion and Tribology of Materials Used in a Novel Reverse Hip Replacement.
Braddon, Linda; Termanini, Zafer; MacDonald, Steven; Parvizi, Jay; Lieberman, Jay; Frankel, Victor; Zuckerman, Joseph
2017-07-05
Total hip arthroplasty has been utilized for the past 50 years as an effective treatment for degenerative, inflammatory and traumatic disorders of the hip. The design of these implants has generally followed the anatomy of the hip as a ball and socket joint with the femoral head representing the ball and the acetabulum representing the socket. We describe a novel hip arthroplasty design in which the "ball" is located on the acetabular side and the "socket" is located on the femoral side. The results of extensive biomechanical testing are described and document wear and corrosion characteristics that are at least equivalent to standard designs. These results support clinical assessment as the next step of the evaluation.
46 CFR 52.01-3 - Definitions of terms used in this part.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Flexible staybolt. A flexible staybolt is a bar made with ball-and-socket joint on one end, the cup of the socket being screwed into the outside sheet and covered with a removable cap, the plain end of the...
46 CFR 52.01-3 - Definitions of terms used in this part.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Flexible staybolt. A flexible staybolt is a bar made with ball-and-socket joint on one end, the cup of the socket being screwed into the outside sheet and covered with a removable cap, the plain end of the...
46 CFR 52.01-3 - Definitions of terms used in this part.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Flexible staybolt. A flexible staybolt is a bar made with ball-and-socket joint on one end, the cup of the socket being screwed into the outside sheet and covered with a removable cap, the plain end of the...
Rainbow, Michael J.; Moore, Douglas C.; Wolfe, Scott W.
2012-01-01
Previous studies have found gender differences in carpal kinematics, and there are discrepancies in the literature on the location of the flexion/extension and radio-ulnar deviation rotation axes of the wrist. It has been postulated that these differences are due to carpal bone size differences rather than gender and that they may be resolved by normalizing the kinematics by carpal size. The purpose of this study was to determine if differences in radio-capitate kinematics are a function of size or gender. We also sought to determine if a best-fit pivot point (PvP) describes the radio-capitate joint as a ball-and-socket articulation. By using an in vivo markerless bone registration technique applied to computed tomography scans of 26 male and 28 female wrists, we applied scaling derived from capitate length to radio-capitate kinematics, characterized by a best-fit PvP. We determined if radio-capitate kinematics behave as a ball-and-socket articulation by examining the error in the best-fit PvP. Scaling PvP location completely removed gender differences (P = 0.3). This verifies that differences in radio-capitate kinematics are due to size and not gender. The radio-capitate joint did not behave as a perfect ball and socket because helical axes representing anatomical motions such as flexion-extension, radio-ulnar deviation, dart throwers, and antidart throwers, were located at distances up to 4.5 mm from the PvP. Although the best-fit PvP did not yield a single center of rotation, it was still consistently found within the proximal pole of the capitate, and rms errors of the best-fit PvP calculation were on the order of 2 mm. Therefore, the ball-and-socket model of the wrist joint center using the best-fit PvP is appropriate when considering gross motion of the hand with respect to the forearm such as in optical motion capture models. However, the ball-and-socket model of the wrist is an insufficient description of the complex motion of the capitate with respect to the radius. These findings may aid in the design of wrist external fixation and orthotics. PMID:18601445
Two degree of freedom camera mount
NASA Technical Reports Server (NTRS)
Ambrose, Robert O. (Inventor)
2003-01-01
A two degree of freedom camera mount. The camera mount includes a socket, a ball, a first linkage and a second linkage. The socket includes an interior surface and an opening. The ball is positioned within an interior of the socket. The ball includes a coupling point for rotating the ball relative to the socket and an aperture for mounting a camera. The first and second linkages are rotatably connected to the socket and slidably connected to the coupling point of the ball. Rotation of the linkages with respect to the socket causes the ball to rotate with respect to the socket.
High temperature control rod assembly
Vollman, Russell E.
1991-01-01
A high temperature nuclear control rod assembly comprises a plurality of substantially cylindrical segments flexibly joined together in succession by ball joints. The segments are made of a high temperature graphite or carbon-carbon composite. The segment includes a hollow cylindrical sleeve which has an opening for receiving neutron-absorbing material in the form of pellets or compacted rings. The sleeve has a threaded sleeve bore and outer threaded surface. A cylindrical support post has a threaded shaft at one end which is threadably engaged with the sleeve bore to rigidly couple the support post to the sleeve. The other end of the post is formed with a ball portion. A hollow cylindrical collar has an inner threaded surface engageable with the outer threaded surface of the sleeve to rigidly couple the collar to the sleeve. the collar also has a socket portion which cooperates with the ball portion to flexibly connect segments together to form a ball and socket-type joint. In another embodiment, the segment comprises a support member which has a threaded shaft portion and a ball surface portion. The threaded shaft portion is engageable with an inner threaded surface of a ring for rigidly coupling the support member to the ring. The ring in turn has an outer surface at one end which is threadably engageably with a hollow cylindrical sleeve. The other end of the sleeve is formed with a socket portion for engagement with a ball portion of the support member. In yet another embodiment, a secondary rod is slidably inserted in a hollow channel through the center of the segment to provide additional strength. A method for controlling a nuclear reactor utilizing the control rod assembly is also included.
Cho, Byung-Ki; Park, Kyoung-Jin; Choi, Seung-Myung; Kang, Sang-Woo; Lee, Hyung-Ki
2016-12-01
Although a ball and socket ankle deformity is usually congenital and asymptomatic, abnormal inversion and eversion mobility can result in recurrent ankle sprain and osteoarthritis. This retrospective study was performed to evaluate the clinical and radiologic outcomes of ankle fusion combined with calcaneal sliding osteotomy for severe arthritic ball and socket ankle deformity. Fourteen patients with severe arthritic ball and socket ankle deformity were followed for more than 3 years after operation. The clinical evaluation consisted of American Orthopaedic Foot & Ankle Society (AOFAS) score, Foot and Ankle Ability Measure (FAAM), visual analog scale (VAS) for pain, and subjective satisfaction score. The period to fusion and union of osteotomy, the change of hindfoot alignment angle, and complications were evaluated radiologically. AOFAS and FAAM scores were significantly improved from an average of 37.4 and 34.5 points to 74.6 and 78.5 points, respectively. VAS for pain with walking over 20 minutes was significantly improved from an average of 8.4 points to 1.9 points. The average satisfaction score of patients was 88.9 points. The difference in heel alignment angle (compared to contralateral side) was significantly improved from an average of 34.8 to 5.4 degrees. There were 2 cases of progressive arthritis in an adjacent joint and 1 case of failed fusion. Ankle fusion combined with calcaneal sliding osteotomy can be an effective operative option for ball and socket ankle deformity with advanced arthritis. In spite of increased complication rate, reliable pain relief, and restoration of gait ability through correcting hindfoot malalignment could improve the quality of life. Level IV, retrospective case series. © The Author(s) 2016.
Biswas, Sondip K; Lee, Jai Eun; Brako, Lawrence; Jiang, Jean X; Lo, Woo-Kuen
2010-11-09
Ball-and-sockets and protrusions are specialized interlocking membrane domains between lens fibers of all species studied. Ball-and-sockets and protrusions are similar in their shape, size, and surface morphology, and are traditionally believed to play a key role in maintaining fiber-to-fiber stability. Here, we evaluate the hypothesis that ball-and-sockets and protrusions possess important structural and functional differences during fiber cell differentiation and maturation. Intact lenses of leghorn chickens (E7 days to P62 weeks old) and rhesus monkeys (1.5-20 years old) were studied with SEM, freeze-fracture TEM, freeze-fracture immunogold labeling (FRIL), and filipin cytochemistry for membrane cholesterol detection. SEM showed that ball-and-sockets were distributed along the long and short sides of hexagonal fiber cells, whereas protrusions were located along the cell corners, from superficial to deep cortical regions in both chicken and monkey lenses. Importantly, by freeze-fracture TEM, we discovered the selective association of gap junctions with all ball-and-sockets examined, but not with protrusions, in both species. In the embryonic chicken lens (E18), the abundant distribution of ball-and-socket gap junctions was regularly found in an approximate zone extending at least 300 μm deep from the equatorial surface of the superficial cortical fibers. Many ball-and-socket gap junctions often protruded deeply into neighboring cells. However, in the mature fibers of monkey lenses, several ball-and-sockets exhibited only partial occupancy of gap junctions with disorganized connexons, possibly due to degradation of gap junctions during fiber maturation and aging. FRIL analysis confirmed that both connexin46 (Cx46) and connexin50 (Cx50) antibodies specifically labeled ball-and-socket gap junctions, but not protrusions. Furthermore, filipin cytochemistry revealed that the ball-and-socket gap junctions contained different amounts of cholesterol (i.e., cholesterol-rich versus cholesterol-free) as seen with the filipin-cholesterol-complexes (FCC) in different cortical regions during maturation. In contrast, the protrusions contained consistently high cholesterol amounts (i.e., 402 FCCs/μm2 membrane) which were approximately two times greater than that of the cholesterol-rich gap junctions (i.e., 188 FCCs/μm2 membrane) found in ball-and-sockets. Gap junctions are regularly associated with all ball-and-sockets examined in metabolically active young cortical fibers, but not with protrusions, in both chicken and monkey lenses. Since these unique gap junctions often protrude deeply into neighboring cells to increase membrane surface areas, they may significantly facilitate cell-to-cell communication between young cortical fiber cells. In particular, the large number of ball-and-socket gap junctions found near the equatorial region may effectively facilitate the flow of outward current toward the equatorial surface for internal circulation of ions in the lens. In contrast, a consistent distribution of high concentrations of cholesterol in protrusions would make the protrusion membrane less deformable and would be more suitable for maintaining fiber-to-fiber stability during visual accommodation. Thus, the ball-and-sockets and protrusions are two structurally and functionally distinct membrane domains in the lens.
Biswas, Sondip K.; Lee, Jai Eun; Brako, Lawrence; Jiang, Jean X.
2010-01-01
Purpose Ball-and-sockets and protrusions are specialized interlocking membrane domains between lens fibers of all species studied. Ball-and-sockets and protrusions are similar in their shape, size, and surface morphology, and are traditionally believed to play a key role in maintaining fiber-to-fiber stability. Here, we evaluate the hypothesis that ball-and-sockets and protrusions possess important structural and functional differences during fiber cell differentiation and maturation. Methods Intact lenses of leghorn chickens (E7 days to P62 weeks old) and rhesus monkeys (1.5–20 years old) were studied with SEM, freeze-fracture TEM, freeze-fracture immunogold labeling (FRIL), and filipin cytochemistry for membrane cholesterol detection. Results SEM showed that ball-and-sockets were distributed along the long and short sides of hexagonal fiber cells, whereas protrusions were located along the cell corners, from superficial to deep cortical regions in both chicken and monkey lenses. Importantly, by freeze-fracture TEM, we discovered the selective association of gap junctions with all ball-and-sockets examined, but not with protrusions, in both species. In the embryonic chicken lens (E18), the abundant distribution of ball-and-socket gap junctions was regularly found in an approximate zone extending at least 300 μm deep from the equatorial surface of the superficial cortical fibers. Many ball-and-socket gap junctions often protruded deeply into neighboring cells. However, in the mature fibers of monkey lenses, several ball-and-sockets exhibited only partial occupancy of gap junctions with disorganized connexons, possibly due to degradation of gap junctions during fiber maturation and aging. FRIL analysis confirmed that both connexin46 (Cx46) and connexin50 (Cx50) antibodies specifically labeled ball-and-socket gap junctions, but not protrusions. Furthermore, filipin cytochemistry revealed that the ball-and-socket gap junctions contained different amounts of cholesterol (i.e., cholesterol-rich versus cholesterol-free) as seen with the filipin-cholesterol-complexes (FCC) in different cortical regions during maturation. In contrast, the protrusions contained consistently high cholesterol amounts (i.e., 402 FCCs/μm2 membrane) which were approximately two times greater than that of the cholesterol-rich gap junctions (i.e., 188 FCCs/μm2 membrane) found in ball-and-sockets. Conclusions Gap junctions are regularly associated with all ball-and-sockets examined in metabolically active young cortical fibers, but not with protrusions, in both chicken and monkey lenses. Since these unique gap junctions often protrude deeply into neighboring cells to increase membrane surface areas, they may significantly facilitate cell-to-cell communication between young cortical fiber cells. In particular, the large number of ball-and-socket gap junctions found near the equatorial region may effectively facilitate the flow of outward current toward the equatorial surface for internal circulation of ions in the lens. In contrast, a consistent distribution of high concentrations of cholesterol in protrusions would make the protrusion membrane less deformable and would be more suitable for maintaining fiber-to-fiber stability during visual accommodation. Thus, the ball-and-sockets and protrusions are two structurally and functionally distinct membrane domains in the lens. PMID:21139982
Corrosion and Tribology of Materials Used in a Novel Reverse Hip Replacement
Braddon, Linda; Termanini, Zafer; MacDonald, Steven; Parvizi, Jay; Lieberman, Jay; Frankel, Victor; Zuckerman, Joseph
2017-01-01
Total hip arthroplasty has been utilized for the past 50 years as an effective treatment for degenerative, inflammatory and traumatic disorders of the hip. The design of these implants has generally followed the anatomy of the hip as a ball and socket joint with the femoral head representing the ball and the acetabulum representing the socket. We describe a novel hip arthroplasty design in which the “ball” is located on the acetabular side and the “socket” is located on the femoral side. The results of extensive biomechanical testing are described and document wear and corrosion characteristics that are at least equivalent to standard designs. These results support clinical assessment as the next step of the evaluation. PMID:28773112
Wang, Song; Wang, Fei; Liao, Zhenhua; Wang, Qingliang; Liu, Yuhong; Liu, Weiqiang
2015-10-01
A ball-on-socket contact configuration was designed to simulate an artificial cervical disk in structure. UHMWPE (ultra high molecular weight polyethylene) hot pressed by powders and Ti6Al4V alloy were selected as the material combination of ball and socket. The socket surface was coated by a ~500 nm C-DLC (carbon ion implantation-diamond like carbon) mixed layer to improve its surface nano hardness and wear resistance. The torsional fretting wear behavior of the ball-on-socket model was tested at different angular displacements under 25% bovine serum lubrication with an axial force of 100 N to obtain more realistic results with that in vivo. The fretting running regimes and wear damage characteristics as well as wear mechanisms for both ball and socket were studied based on 2D (two dimension) optical microscope, SEM (scanning electron microscope) and 3D (three dimension) profiles. With the increase of angular displacement amplitude from 1° to 7°, three types of T-θ (Torsional torque-angular displacement amplitude) curves (i.e., linear, elliptical and parallelogram loops) corresponding to running regimes of PSR (partial slip regime), MR (mixed regime) and SR (slip regime) were observed and analyzed. Both the central region and the edge zone of the ball and socket were damaged. The worn surfaces were characterized by wear scratches and wear debris. In addition, more severe wear damage and more wear debris appeared on the central region of the socket at higher angular displacement amplitude. The dominant damage mechanism was a mix of surface scratch, adhesive wear and abrasive wear for the UHMWPE ball while that for the coated socket was abrasive wear by PE particles and some polishing and rolling process on the raised overgrown DLC grains. The frictional kinetic behavior, wear type, damage region and damage mechanism for the ball-on-socket model revealed significant differences with those of a ball-on-flat contact while showing better consistency with that of in vitro cervical prosthesis simulations according to the literature. Copyright © 2015. Published by Elsevier B.V.
NASA Technical Reports Server (NTRS)
Goetz, C.; Ingle, W. M. (Inventor)
1980-01-01
A ball valve particularly suited for use in the handling of highly corrosive fluids is described. It is characterized by a valve housing formed of communicating segments of quartz tubing, a pair of communicating sockets disposed in coaxial alignment with selected segments of tubing for establishing a pair of inlet ports communicating with a common outlet port, a ball formed of quartz material supported for displacement between the sockets and configured to be received alternately thereby, and a valve actuator including a rod attached to the ball for selectively displacing the ball relative to each of the sockets for controlling fluid flow through the inlet ports.
Photovoltaic Universal Joints: Ball-and-Socket Interfaces in Molecular Photovoltaic Cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tremblay, Noah J.; Gorodetsky, Alon A.; Cox, Marshall P.
2010-02-15
A new approach toward higher efficiency organic photovoltaic devices (OPVs) is described. Complementarity in shape between the donor (contorted hexabenzocoronene, see picture) and acceptor (buckminsterfullerene) molecules results in OPVs that perform surprisingly well. This exploitation of host-guest chemistry at the organic/organic interface demonstrates a new direction for OPV device design.
Choi, Jisoo; Shin, Dong-Ah; Kim, Sohee
2017-03-15
A three-dimensional finite element model of intact lumbar spine was constructed and four surgical finite element models implanted with ball-and-socket artificial discs with four different radii of curvature were compared. To investigate biomechanical effects of the curvature of ball-and-socket artificial disc using finite element analysis. Total disc replacement (TDR) has been accepted as an alternative treatment because of its advantages over spinal fusion methods in degenerative disc disease. However, the influence of the curvature of artificial ball-and-socket discs has not been fully understood. Four surgical finite element models with different radii of curvature of ball-and-socket artificial discs were constructed. The range of motion (ROM) increased with decreasing radius of curvature in extension, flexion, and lateral bending, whereas it increased with increasing radius of curvature in axial torsion. The facet contact force was minimum with the largest radius of curvature in extension, flexion, and lateral bending, whereas it was maximum with the largest radius in axial torsion. It was also affected by the disc placement, more with posterior placement than anterior placement. The stress in L4 cancellous bone increased when the radius of curvature was too large or small. The geometry of ball-and-socket artificial disc significantly affects the ROM, facet contact force, and stress in the cancellous bone at the surgical level. The implication is that in performing TDR, the ball-and-socket design may not be ideal, as ROM and facet contact force are sensitive to the disc design, which may be exaggerated by the individual difference of anatomical geometry. N/A.
Modified Ball and Socket Coupling
Conley, Jr, W. R.; Pitman, R. W.
1961-05-23
A ball and socket coupling arrangement is given in which the male and female members may be engaged or disengaged without visual aid. The female member has an internal spherical seat through which slots are provided to accommodate appropriately arranged and shaped ribs in the male ball member. After engagement of the members, one or both are rotated to lock them together to prevent accidental disengagement.
MODIFIED BALL AND SOCKET COUPLING
Kalen, D.D.
1961-05-23
A ball and socket coupling arrangement is described in which the male and female members may be engaged or disengaged without visual aid. The female member has an internal spherical seat through which slots are provided to accommodate appropriately arranged and shaped ribs in the ball member. After engagement of the members, one or both are rotated to lock them together to prevent accidental disengagement. (AEC)
The Efficiency of Small Bearings in Instruments of the Type Used in Aircraft
NASA Technical Reports Server (NTRS)
Norton, F H
1921-01-01
This report deals with the construction and properties of bearings and pivots for use in instruments. The static and running friction for both thrust and radial loads was determined for a number of conical pivots and cylindrical and ball bearings. The static rocking friction was also measured for several conical and ball bearings under a heavy load, especially to determine their suitability for use in N. P. L. (National Physical Laboratory) type wind tunnel balance. In constructing conical pivots and sockets it was found that the pivots should be hardened and highly polished, preferably with a revolving lap, and that the sockets should be made by punching with a hardened and polished punch. It was found that for a light load the conical pivots give less friction than any other type, and their wearing qualities when hardened are excellent. Very small ball bearings are unsatisfactory because the proportional accuracy of the balls and races is not high enough to insure smooth running. For rocking pivots under heavy loads it was found that a ball-and-socket bearing, consisting of a hemispherical socket and a sphere of smaller diameter concentric with it, with a row of small balls resting between the two, was superior to a pivot resting in a socket. It was found that vibration such as occurs in an airplane will greatly reduce the static friction of a pivot or bearing, in some cases to as little as one-twentieth of its static value.
Self-assembling segmented coiled tubing
Raymond, David W.
2016-09-27
Self-assembling segmented coiled tubing is a concept that allows the strength of thick-wall rigid pipe, and the flexibility of thin-wall tubing, to be realized in a single design. The primary use is for a drillstring tubular, but it has potential for other applications requiring transmission of mechanical loads (forces and torques) through an initially coiled tubular. The concept uses a spring-loaded spherical `ball-and-socket` type joint to interconnect two or more short, rigid segments of pipe. Use of an optional snap ring allows the joint to be permanently made, in a `self-assembling` manner.
Integrated Structural and Cable Connector
NASA Technical Reports Server (NTRS)
Totah, R. S.
1982-01-01
Ball-and-socket coupling includes fiber-optic cable. Three steps couple two parts of fiber-optic cable: ball is inserted into socket; cone is released in, and cable moves toward plug. Sleeve is pulled to end of its travel and cable and plug are mated. Device is a quick-connect/disconnect coupling that has application in hazardous environments, such as space, undersea and nuclear installations.
NASA Technical Reports Server (NTRS)
Wilson, Andrew (Inventor); Punnoose, Andrew (Inventor); Strausser, Katherine (Inventor); Parikh, Neil (Inventor)
2011-01-01
A mobile robotic unit features a main body, a plurality of legs for supporting the main body on and moving the main body in forward and reverse directions about a base surface, and a drive assembly. According to an exemplary embodiment each leg includes a respective pivotal hip joint, a pivotal knee joint, and a wheeled foot adapted to roll along the base surface. Also according to an exemplary embodiments the drive assembly includes a motor operatively associated with the hip and knee joints and the wheeled foot for independently driving pivotal movement of the hip joint and the knee joint and rolling motion of the wheeled foot. The hip joint may include a ball-and-socket-type joint interconnecting top portion of the leg to the main body, such that the hip joint is adapted to pivot said leg in a direction transverse to a forward-and-reverse direction.
Ball and socket nanostructures: New supramolecular chemistry based on cyclotriveratrylene
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steed, J.W.; Junk, P.C.; Atwood, J.L.
1994-11-02
This paper outlines new vistas for the inclusion chemistry of hosts based upon the cyclotriveratrylene motif. A simple method of retrieving pure fullerenes from fullerite without the use of chromatographic techniques has been outlined, and a new class of ball and socket-type inclusion species has been realized by simple modification of either host or guest electronic and steric properties. 14 refs., 2 figs.
Elbow and knee joint for hard space suits
NASA Technical Reports Server (NTRS)
Vykukal, H. C.
1986-01-01
An elbow or knee joint for a hard space suit or similar usage is formed of three serially connected rigid sections which have truncated spherical configurations. The ends of each section form solid geometric angles, and the sections are interconnected by hermetically sealed ball bearings. The outer two sections are fixed together for rotation in a direction opposite to rotation of the center section. A preferred means to make the outer sections track each other in rotation comprises a rotatable continuous bead chain which engages sockets circumferentially spaced on the facing sides of the outer races of the bearings. The joint has a single pivot point and the bearing axes are always contained in a single plane for any articulation of the joint. Thus flexure of the joint simulates the coplanar flexure of the knee or elbow and is not susceptible to lockup.
... This type of implant is an artificial hip socket that is created by fitting a metal ball ... particles (ions) can get released into the hip socket and sometimes the bloodstream, causing cobalt toxicity. This ...
Automatic ball bar for a coordinate measuring machine
Jostlein, H.
1997-07-15
An automatic ball bar for a coordinate measuring machine determines the accuracy of a coordinate measuring machine having at least one servo drive. The apparatus comprises a first and second gauge ball connected by a telescoping rigid member. The rigid member includes a switch such that inward radial movement of the second gauge ball relative to the first gauge ball causes activation of the switch. The first gauge ball is secured in a first magnetic socket assembly in order to maintain the first gauge ball at a fixed location with respect to the coordinate measuring machine. A second magnetic socket assembly secures the second gauge ball to the arm or probe holder of the coordinate measuring machine. The second gauge ball is then directed by the coordinate measuring machine to move radially inward from a point just beyond the length of the ball bar until the switch is activated. Upon switch activation, the position of the coordinate measuring machine is determined and compared to known ball bar length such that the accuracy of the coordinate measuring machine can be determined. 5 figs.
Automatic ball bar for a coordinate measuring machine
Jostlein, Hans
1997-01-01
An automatic ball bar for a coordinate measuring machine determines the accuracy of a coordinate measuring machine having at least one servo drive. The apparatus comprises a first and second gauge ball connected by a telescoping rigid member. The rigid member includes a switch such that inward radial movement of the second gauge ball relative to the first gauge ball causes activation of the switch. The first gauge ball is secured in a first magnetic socket assembly in order to maintain the first gauge ball at a fixed location with respect to the coordinate measuring machine. A second magnetic socket assembly secures the second gauge ball to the arm or probe holder of the coordinate measuring machine. The second gauge ball is then directed by the coordinate measuring machine to move radially inward from a point just beyond the length of the ball bar until the switch is activated. Upon switch activation, the position of the coordinate measuring machine is determined and compared to known ball bar length such that the accuracy of the coordinate measuring machine can be determined.
Spherical Joint Piston and Connecting Rod Developed
NASA Technical Reports Server (NTRS)
1996-01-01
Under an interagency agreement with the Department of Energy, the NASA Lewis Research Center manages a Heavy-Duty Diesel Engine Technology (HDET) research program. The overall program objectives are to reduce fuel consumption through increased engine efficiency, reduce engine exhaust emissions, and provide options for the use of alternative fuels. The program is administered with a balance of research contracts, university research grants, and focused in-house research. The Cummins Engine Company participates in the HDET program under a cost-sharing research contract. Cummins is researching and developing in-cylinder component technologies for heavy-duty diesel engines. An objective of the Cummins research is to develop technologies for a low-emissions, 55-percent thermal efficiency (LE-55) engine. The best current-production engines in this class achieve about 46-percent thermal efficiency. Federal emissions regulations are driving this technology. Regulations for heavy duty diesel engines were tightened in 1994, more demanding emissions regulations are scheduled for 1998, and another step is planned for 2002. The LE-55 engine emissions goal is set at half of the 1998 regulation level and is consistent with plans for 2002 emissions regulations. LE-55 engine design requirements to meet the efficiency target dictate a need to operate at higher peak cylinder pressures. A key technology being developed and evaluated under the Cummins Engine Company LE-55 engine concept is the spherical joint piston and connecting rod. Unlike conventional piston and connecting rod arrangements which are joined by a pin forming a hinged joint, the spherical joint piston and connecting rod use a ball-and-socket joint. The ball-and-socket arrangement enables the piston to have an axisymmetric design allowing rotation within the cylinder. The potential benefits of piston symmetry and rotation are reduced scuffing, improved piston ring sealing, improved lubrication, mechanical and thermal load symmetry, reduced bearing stresses, reduced running clearances, and reduced oil consumption. The spherical joint piston is a monolithic, squeeze-cast, fiber-reinforced aluminum piston. The connecting rod has a ball end that seats on a spherical saddle within the piston and is retained by a pair of aluminum bronze holder rings. The holder rings are secured by a threaded ring that mates with the piston. As part of the ongoing research and development activity, the Cummins Engine Company successfully completed a 100-hr test of the spherical joint piston and connecting rod at LE- 55 peak steady-state engine conditions. In addition, a 100-hr transient cycle test that varied engine conditions between LE-55 no-load and LE-55 full-load was successfully completed.
... of metal and the socket is made of plastic (polyethylene) or has a plastic lining. Ceramic-on-Polyethylene: The ball is made of ceramic and the socket is made of plastic (polyethylene) or has a plastic lining. Metal-on- ...
Combination Space Station Handrail Clamp and Pointing Device
NASA Technical Reports Server (NTRS)
Hughes, Stephen J. (Inventor)
1999-01-01
A device for attaching an experiment carrier to a space station handrail is provided. The device has two major components, a clamping mechanism for attachment to a space station handrail, and a pointing carrier on which an experiment package can be mounted and oriented. The handrail clamp uses an overcenter mechanism and the carrier mechanism uses an adjustable preload ball and socket for carrier positioning. The handrail clamp uses a stack of disk springs to provide a spring loaded button. This configuration provides consistent clamping force over a range of possible handrail thicknesses. Three load points are incorporated in the clamping mechanism thereby spreading the clamping load onto three separate points on the handrail. A four bar linkage is used to provide for a single actuation lever for all three load points. For additional safety, a secondary lock consisting of a capture plate and push lock keeps the clamp attached to the handrail in the event of main clamp failure. For the carrier positioning mechanism, a ball in a spring loaded socket uses friction to provide locking torque; however. the ball and socket are torque limited so that the ball ran slip under kick loads (125 pounds or greater). A lead screw attached to disk spring stacks is used to provide an adjustable spring force on the socket. A locking knob is attached to the lead screw to allow for hand manipulation of the lead screw.
Telescoping magnetic ball bar test gage
Bryan, J.B.
1982-03-15
A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengagable servo drives which cannot be clutched out. Two gage balls are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit and a rigid member. One gage ball is secured by a magnetic socket knuckle assembly which fixes its center with respect to the machine being tested. The other gage ball is secured by another magnetic socket knuckle assembly which is engaged or held by the machine in such manner that the center of that ball is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball. As the moving ball executes its trajectory, changes in the radial distance between the centers of the two balls caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly actuated by the parallel reed flexure unit. Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball locations, thereby determining the accuracy of the machine.
Arthrodesis of the first metatarsophalangeal joint using a dorsal titanium contoured plate.
Flavin, Robert; Stephens, Michael M
2004-11-01
Arthrodesis of the first metatarsophalangeal joint (MTPJ) is used to treat a variety of foot pathologies. Numerous methods of internal fixation and bone end preparation have been reported. In an effort to bring together the best features of the various internal fixation devices, a low-profile contoured titanium plate (LPCT) using a compression screw was designed to be used with a ball-and-socket bone end preparation. A prospective study was carried out to determine the efficacy of this technique. First MTPJ arthrodesis using an LPCT was done in 12 patients (10 women and two men) either as an isolated procedure (seven patients) or in conjunction with other forefoot procedures (five patients). The changes in the level of pain and activities of daily living were evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) hallux score and the Short-Form 36 (SF-36) score. Time to bone union also was assessed. Mean followup was 18 months (+/-6 months). Statistically significant increases in the AOFAS hallux score and the SF-36 score were noted (p = .002 and .001, respectively). All radiographs showed bone union at 6 weeks and an appropriate degree of hallux dorsiflexion in relation to the first metatarsal (20 to 25 degrees). The combination of the LPCT plate and a ball-and-socket bone-end preparation has both operative and biomechanical advantages over other fixation techniques. This combination ensures that the anatomical length of the first ray is only minimally shortened and the angle of plantarflexion of the first metatarsal is maintained, resulting in preservation of medial column stability and a better functional result.
Ball-and-socket tectonic rotation during the 2013 Mw 7.7 Balochistan earthquake
NASA Astrophysics Data System (ADS)
Barnhart, W. D.; Hayes, G. P.; Briggs, R. W.; Gold, R. D.; Bilham, R.
2014-10-01
The September 2013 Mw 7.7 Balochistan earthquake ruptured a ∼200-km-long segment of the curved Hoshab fault in southern Pakistan with 10 ± 0.2 m of peak sinistral and ∼ 1.7 ± 0.8 m of dip slip. This rupture is unusual because the fault dips 60 ± 15° towards the focus of a small circle centered in northwest Pakistan, and, despite a 30° increase in obliquity along strike, the ratios of strike and dip slip remain relatively uniform. Surface displacements and geodetic and teleseismic source inversions quantify a bilateral rupture that propagated rapidly at shallow depths from a transtensional jog near the northern end of the rupture. Static friction prior to rupture was unusually weak (μ < 0.05), and friction may have approached zero during dynamic rupture. Here we show that the inward-dipping Hoshab fault defines the northern rim of a structural unit in southeast Makran that rotates - akin to a 2-D ball-and-socket joint - counter-clockwise in response to India's penetration into the Eurasian plate. This rotation accounts for complexity in the Chaman fault system and, in principle, reduces seismic potential near Karachi; nonetheless, these findings highlight deficiencies in strong ground motion equations and tectonic models that invoke Anderson-Byerlee faulting predictions.
Ball-and-socket tectonic rotation during the 2013 Mw7.7 Balochistan earthquake
Barnhart, William D.; Hayes, Gavin P.; Briggs, Richard W.; Gold, Ryan D.; Bilham, R.
2014-01-01
The September 2013 Mw7.7 Balochistan earthquake ruptured a ∼200-km-long segment of the curved Hoshab fault in southern Pakistan with 10±0.2 m of peak sinistral and ∼1.7±0.8 m of dip slip. This rupture is unusual because the fault dips 60±15° towards the focus of a small circle centered in northwest Pakistan, and, despite a 30° increase in obliquity along strike, the ratios of strike and dip slip remain relatively uniform. Surface displacements and geodetic and teleseismic source inversions quantify a bilateral rupture that propagated rapidly at shallow depths from a transtensional jog near the northern end of the rupture. Static friction prior to rupture was unusually weak (μ<0.05), and friction may have approached zero during dynamic rupture. Here we show that the inward-dipping Hoshab fault defines the northern rim of a structural unit in southeast Makran that rotates – akin to a 2-D ball-and-socket joint – counter-clockwise in response to India's penetration into the Eurasian plate. This rotation accounts for complexity in the Chaman fault system and, in principle, reduces seismic potential near Karachi; nonetheless, these findings highlight deficiencies in strong ground motion equations and tectonic models that invoke Anderson–Byerlee faulting predictions.
Tang, Qiaohong; Mo, Zhongjun; Yao, Jie; Li, Qi; Du, Chenfei; Wang, Lizhen; Fan, Yubo
2014-12-01
This study was aimed to estimate the effect of different ProDisc-C arthroplasty designs after it was implanted to C5-C6 cervicalspine. Finite element (FE) model of intact C5-C6 segments including the vertebrae and disc was developed and validated. Ball-and-socket artificial disc prosthesis model (ProDisc-C, Synthes) was implanted into the validated FE model and the curvature of the ProDisc-C prosthesis was varied. All models were loaded with compressed force 74 N and the pure moment of 1.8 Nm along flexion-extension and bilateral bending and axial torsion separately. The results indicated that the variation in the curvature of ball and socket configuration would influence the range of motion in flexion/extension, while there were not apparently differences under other conditions of loads. The method increasing the curvature will solve the stress concentration of the polyethylene, but it will also bring adverse outcomes, such as facet joint force increasing and ligament tension increasing. Therefore, the design of artificial discs should be considered comprehensively to reserve the range of motion as well as to avoid the adverse problems, so as not to affect the long-term clinical results.
46 CFR 56.75-30 - Pipe joining details.
Code of Federal Regulations, 2010 CFR
2010-10-01
... be either of the socket or butt type. When butt joints are employed the edges to be joined shall be.... Circumferential joints may be either of the butt or socket type. Where butt joints are employed, the included... annular clearance of socket joints shall be held to small clearances which experience indicates is...
46 CFR 56.75-30 - Pipe joining details.
Code of Federal Regulations, 2014 CFR
2014-10-01
... be either of the socket or butt type. When butt joints are employed the edges to be joined shall be.... Circumferential joints may be either of the butt or socket type. Where butt joints are employed, the included... annular clearance of socket joints shall be held to small clearances which experience indicates is...
46 CFR 56.75-30 - Pipe joining details.
Code of Federal Regulations, 2013 CFR
2013-10-01
... be either of the socket or butt type. When butt joints are employed the edges to be joined shall be.... Circumferential joints may be either of the butt or socket type. Where butt joints are employed, the included... annular clearance of socket joints shall be held to small clearances which experience indicates is...
46 CFR 56.75-30 - Pipe joining details.
Code of Federal Regulations, 2012 CFR
2012-10-01
... be either of the socket or butt type. When butt joints are employed the edges to be joined shall be.... Circumferential joints may be either of the butt or socket type. Where butt joints are employed, the included... annular clearance of socket joints shall be held to small clearances which experience indicates is...
46 CFR 56.75-30 - Pipe joining details.
Code of Federal Regulations, 2011 CFR
2011-10-01
... be either of the socket or butt type. When butt joints are employed the edges to be joined shall be.... Circumferential joints may be either of the butt or socket type. Where butt joints are employed, the included... annular clearance of socket joints shall be held to small clearances which experience indicates is...
Telescoping magnetic ball bar test gage
Bryan, J.B.
1984-03-13
A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengageable servo drives which cannot be clutched out is disclosed. Two gage balls are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit and a rigid member. One gage ball is secured by a magnetic socket knuckle assembly which fixes its center with respect to the machine being tested. The other gage ball is secured by another magnetic socket knuckle assembly which is engaged or held by the machine in such manner that the center of that ball is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball. As the moving ball executes its trajectory, changes in the radial distance between the centers of the two balls caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly actuated by the parallel reed flexure unit. Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball locations, thereby determining the accuracy of the machine. 3 figs.
Jin, Z M; Dowson, D; Fisher, J
1997-01-01
Lubrication mechanisms and contact mechanics have been analysed for total hip joint replacements made from hard bearing surfaces such as metal-on-metal and ceramic-on-ceramic. A similar analysis for ultra-high molecular weight polyethylene (UHMWPE) against a hard bearing surface has also been carried out and used as a reference. The most important factor influencing the predicted lubrication film thickness has been found to be the radial clearance between the ball and the socket. Full fluid film lubrication may be achieved in these hard/hard bearings provided that the surface finish of the bearing surface and the radial clearance are chosen correctly and maintained. Furthermore, there is a close relation between the predicted contact half width and the predicted lubrication film thickness. Therefore, it is important to analyse the contact mechanics in artificial hip joint replacements. Practical considerations of manufacturing these bearing surfaces have also been discussed.
46 CFR 56.30-30 - Brazed joints.
Code of Federal Regulations, 2010 CFR
2010-10-01
....75). Brazed socket-type joints shall be made with suitable brazing alloys. The minimum socket depth shall be sufficient for the intended service. Brazing alloy shall either be end-fed into the socket or shall be provided in the form of a preinserted ring in a groove in the socket. The brazing alloy shall...
46 CFR 56.30-30 - Brazed joints.
Code of Federal Regulations, 2013 CFR
2013-10-01
....75). Brazed socket-type joints shall be made with suitable brazing alloys. The minimum socket depth shall be sufficient for the intended service. Brazing alloy shall either be end-fed into the socket or shall be provided in the form of a preinserted ring in a groove in the socket. The brazing alloy shall...
46 CFR 56.30-30 - Brazed joints.
Code of Federal Regulations, 2011 CFR
2011-10-01
....75). Brazed socket-type joints shall be made with suitable brazing alloys. The minimum socket depth shall be sufficient for the intended service. Brazing alloy shall either be end-fed into the socket or shall be provided in the form of a preinserted ring in a groove in the socket. The brazing alloy shall...
46 CFR 56.30-30 - Brazed joints.
Code of Federal Regulations, 2014 CFR
2014-10-01
....75). Brazed socket-type joints shall be made with suitable brazing alloys. The minimum socket depth shall be sufficient for the intended service. Brazing alloy shall either be end-fed into the socket or shall be provided in the form of a preinserted ring in a groove in the socket. The brazing alloy shall...
46 CFR 56.30-30 - Brazed joints.
Code of Federal Regulations, 2012 CFR
2012-10-01
....75). Brazed socket-type joints shall be made with suitable brazing alloys. The minimum socket depth shall be sufficient for the intended service. Brazing alloy shall either be end-fed into the socket or shall be provided in the form of a preinserted ring in a groove in the socket. The brazing alloy shall...
Telescoping magnetic ball bar test gage
Bryan, James B.
1984-01-01
A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengageable servo drives which cannot be clutched out. Two gage balls (10, 12) are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit (14) and a rigid member (16, 18, 20, 22, 24). One gage ball (10) is secured by a magnetic socket knuckle assembly (34) which fixes its center with respect to the machine being tested. The other gage ball (12) is secured by another magnetic socket knuckle assembly (38) which is engaged or held by the machine in such manner that the center of that ball (12) is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball (10). As the moving ball (12) executes its trajectory, changes in the radial distance between the centers of the two balls (10, 12) caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly (50, 52, 54, 56, 58, 60) actuated by the parallel reed flexure unit (14). Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball (10) locations, thereby determining the accuracy of the machine.
Fatigue strength of socket welded pipe joint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higuchi, Makoto; Hayashi, Makoto; Yamauchi, Takayoshi
1995-12-01
Fully reversed four point bending fatigue tests were carried out on small diameter socket welded joints made of carbon steels. Experimental parameters were pipe diameter, thicknesses of pipe and socket wall, throat depth and shape of fillet welds, slip-on and diametral gaps in the socket welding, lack of penetration at the root of fillet welds, and peening of fillet welds. In most cases a fatigue crack started from the root of the fillet, but in the case of higher stress amplitude, it tended to start from the toe of fillet. The standard socket welded joint for a pipe with amore » 50 mm nominal diameter showed a relatively low fatigue strength of 46 MPa in stress amplitude at the 10{sup 7} cycles failure life. This value corresponds to about 1/5 of that for the smoothed base metal specimens in axial fatigue. The fatigue strength decreased with increasing pipe diameter, and increased with increasing thickness of the pipe and socket wall. The effects of throat depth and shape of fillet welds on fatigue strength were not significant. Contrary to expectation, the fatigue strength of a socket welded joint without slip-on gap is Higher than that of the joint with a normal gap. A lack of penetration at the root deleteriously reduced fatigue strength, showing 14 MPa in stress amplitude at the 10{sup 7} cycles failure life for the 50 mm diameter socket joint.« less
Pollicisation: The Myth about Creating a Pseudo-Trapezium.
Mennen, Ulrich
2018-06-01
We have performed 14 pollicisations without creating a "pseudo-trapezium" from the metacarpal head. The entire metacarpal of the intended finger to be pollicised is removed and the proximal phalanx of the finger is inserted into the space left by the base of the excised metacarpal. The results are good to excellent in all 14 cases followed for 2-9 years. The advantages are that the operation is much simpler, thus also much quicker. The new thumb looks more like a thumb (not too long) and is more stable (ball-and-socket joint), with no long term complications often seen with the pseudo-trapezium.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higuchi, Makoto; Nakagawa, Akira; Chujo, Noriyuki
1996-12-01
Rotating bending fatigue tests were conducted on socket welded joints of a nominal diameter 20 mm, and effects of root defect and other various factors, including post-weld heat treatment (PWHT), pipe wall thickness, and socket wall thickness, were investigated. The socket joints exhibited, in the rotating bending fatigue mode, fatigue strengths that were markedly lower than the same 20 mm diameter joints in four-point bending fatigue. Also, where the latter specimens failed always at the toe, root-failures occurred in rotating bending fatigue. When PWHT`d, however, the fatigue strength showed a remarkable improvement, while the failure site reverted to toe. Thickermore » pipe walls and socket walls gave rise to higher fatigue strength. A formula relating the size of root defects to the fatigue strength reduction has been proposed.« less
Residual-stress measurement in socket welded joints by neutron diffraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayashi, M.; Ishiwata, M.; Minakawa, N.
1994-12-31
Neutron diffraction measurements of lattice strains provide spatial maps of residual stress near welds in ferritic steel socket joints. The highest tensile stresses in the welds are found in axial, radial and hoop direction at the weld root. However, the highest tensile stress in the axial direction is about 110MPa. Balancing compressive stresses are found near the surface of the socket weld fusion zone. Heat treatment at 600 C for 2 hours is sufficient to relieve residual stress in socket welds.
NASA Astrophysics Data System (ADS)
Barnhart, W. D.; Hayes, G. P.; Briggs, R. W.; Gold, R. D.; Bilham, R. G.
2014-12-01
The September 2013 Mw7.7 Balochistan strike-slip earthquake ruptured a ~200 km long segment of the curved Hoshab fault within the Makran accretionary prism - the active zone of convergence between the northward subducting Arabia plate and overriding Eurasia. The Hoshab fault ruptured bilaterally with ~10 m of mean sinistral and ~1.7 m of dip slip along the length of the rupture, quantified jointly from geodetic and seismological observations. This rupture is unusual because the fault dips ~60o towards the focus of a small circle centered in northwest Pakistan, and, despite a 30o increase in obliquity along the curving strike of the fault with respect to Arabia:Eurasia convergence, the ratio of strike and dip slip remain relatively uniform. Static friction prior to rupture was unusually weak ( <0.05) as inferred from topographic and slab profiles, and friction may have approached zero during dynamic rupture, thus permitting in part this unusual event. In this presentation, we argue that the northward dipping Hosab fault defines the northern rim of a structural unit in southeast Makran. This unit rotates - akin to a 2-D ball-and-socket joint - counter clockwise in response to India's penetration into the Eurasia plate. According to this interpretation, the mechanically weak Makran accretionary prism is subjected to a highly heterogeneous strain and deforms in response to convergence from both the Arabia and India plates. Rotation of the southeast Makran block accounts for complexity in the Chaman fault system and, in principle, reduces the seismic potential near Karachi by accommodating some slip along the southern Ornach-Nal fault. At the same time, geological indicators and along-strike fault slip profiles indicate that the Hoshab fault may also slip as a reverse fault in response to Arabia:Eurasia convergence - indicating that a single fault may accommodate multiple components of strain partitioning in a heterogeneous strain field over several seismic cycles.
Nanofibers of fullerene C60 through interplay of ball-and-socket supermolecules.
Hubble, Lee J; Raston, Colin L
2007-01-01
Mixing solutions of p-tBu-calix[5]arene and C(60) in toluene results in a 1:1 complex (C(60)) intersection(p-tBu-calix[5]arene), which precipitates as nanofibers. The principle structural unit is based on a host-guest ball-and-socket nanostructure of the two components, with an extended structure comprising zigzag/helical arrays of fullerenes (powder X-ray diffraction data coupled with molecular modeling). Under argon at temperatures above 309 degrees C, the fibers undergo selective volatilization of the calixarenes to afford C(60)-core nanostructures encapsulated in a graphitic material sheath, which exhibits a dramatic increase in surface area. Above 650 degrees C the material exhibits an ohmic conductance response, due to the encapsulation process.
21 CFR 872.3680 - Polytetrafluoroethylene (PTFE) vitreous carbon materials.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the sockets in which teeth are rooted) or intended to coat metal surgical implants to be placed in the alveoli (sockets in which the teeth are rooted) or the temporomandibular joints (the joint between the...
21 CFR 872.3680 - Polytetrafluoroethylene (PTFE) vitreous carbon materials.
Code of Federal Regulations, 2013 CFR
2013-04-01
... the sockets in which teeth are rooted) or intended to coat metal surgical implants to be placed in the alveoli (sockets in which the teeth are rooted) or the temporomandibular joints (the joint between the...
21 CFR 872.3680 - Polytetrafluoroethylene (PTFE) vitreous carbon materials.
Code of Federal Regulations, 2014 CFR
2014-04-01
... the sockets in which teeth are rooted) or intended to coat metal surgical implants to be placed in the alveoli (sockets in which the teeth are rooted) or the temporomandibular joints (the joint between the...
21 CFR 872.3680 - Polytetrafluoroethylene (PTFE) vitreous carbon materials.
Code of Federal Regulations, 2011 CFR
2011-04-01
... the sockets in which teeth are rooted) or intended to coat metal surgical implants to be placed in the alveoli (sockets in which the teeth are rooted) or the temporomandibular joints (the joint between the...
21 CFR 872.3680 - Polytetrafluoroethylene (PTFE) vitreous carbon materials.
Code of Federal Regulations, 2012 CFR
2012-04-01
... the sockets in which teeth are rooted) or intended to coat metal surgical implants to be placed in the alveoli (sockets in which the teeth are rooted) or the temporomandibular joints (the joint between the...
Ball-and-Socket Mount for Instruments
NASA Technical Reports Server (NTRS)
Kaelber, E.
1986-01-01
Jaws engage instrument precisely but release it readily. Mounting mechanism holds scientific instrument securely, allows instrument to be oriented, and minimizes conduction of heat to and from instrument. Mechanism also allows quick replacement of instrument.
Ball assisted device for analytical surface sampling
ElNaggar, Mariam S; Van Berkel, Gary J; Covey, Thomas R
2015-11-03
A system for sampling a surface includes a sampling probe having a housing and a socket, and a rolling sampling sphere within the socket. The housing has a sampling fluid supply conduit and a sampling fluid exhaust conduit. The sampling fluid supply conduit supplies sampling fluid to the sampling sphere. The sampling fluid exhaust conduit has an inlet opening for receiving sampling fluid carried from the surface by the sampling sphere. A surface sampling probe and a method for sampling a surface are also disclosed.
Strength evaluation of socket joints
NASA Technical Reports Server (NTRS)
Rash, Larry C.
1994-01-01
This report documents the development of a set of equations that can be used to provide a relatively simple solution for identifying the strength of socket joints and for most cases avoid the need of more lengthy analyses. The analytical approach was verified by comparison of the contact load distributions to results obtained from a finite element analysis. The contacting surfaces for the specific joint in this analysis are in the shape of frustrums of a cone and are representative of the tapered surfaces in the socket-type joints used to join segments of model support systems for wind tunnels. The results are in the form of equations that can be used to determine the contact loads and stresses in the joint from the given geometry and externally applied loads. Equations were determined to define the bending moments and stresses along the length of the joints based on strength and materials principles. The results have also been programmed for a personal computer and a copy of the program is included.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pimputkar, S.M.; McCoy, J.K.; Stets, J.A.
1991-03-01
The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipemore » dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact test was modified to test socket fusion joint samples in shear. The developed shear impact energy test data were found to be reliable measures of strength if the setups for conditions were meticulously identical. A parameter, termed the socket joining parameter, was found to characterize the joining conditions. It is a strong function of melt volume at the end of the heating phase, and physically, it is polyethylene transported parallel to the axis during insertion. The results for three resins are presented in the form of three nomographs. The nomographs may be used to select the required heater temperature or the heating time, for a given ambient temperature and a PE resin, to ensure a structurally sound socket heat fusion joint.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pimputkar, S.M.; McCoy, J.K.; Stets, J.A.
1991-03-01
The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipemore » dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact test was modified to test socket fusion joint samples in shear. The developed shear impact energy test data were found to be reliable measures of strength if the setup conditions were meticulously identical. A parameter, termed the socket joining parameter, was found to characterize the joining conditions. It is a strong function of melt volume at the end of the heating phase, and, physically, it is polyethylene transported parallel to the axis during insertion. The results for three resins are presented in the form of three nomographs. The nomographs may be used to select the required heater temperature or the heating time, for a given ambient temperature and a PE resin, to ensure a structurally sound socket heat fusion joint.« less
... of the joint, is called the condyle. The socket is called the articular fossa. Between the condyle ... that is located between the jawbone and the socket. A displaced disk may produce clicking or popping ...
Chertock, deceased, Alan J.; Fox, Jack N.; Weissinger, Robert B.
1982-01-01
A reactor refueling method utilizing a vibrating fuel grapple for removing spent fuel assemblies from a reactor core which incorporates a pneumatic vibrator in the grapple head, enabling additional withdrawal capability without exceeding the allowable axial force limit. The only moving part in the vibrator is a steel ball, pneumatically driven by a gas, such as argon, around a track, with centrifugal force created by the ball being transmitted through the grapple to the assembly handling socket.
Inspection system for a turbine blade region of a turbine engine
Smed, Jan P [Winter Springs, FL; Lemieux, Dennis H [Casselberry, FL; Williams, James P [Orlando, FL
2007-06-19
An inspection system formed at least from a viewing tube for inspecting aspects of a turbine engine during operation of the turbine engine. An outer housing of the viewing tube may be positioned within a turbine engine using at least one bearing configured to fit into an indentation of a support housing to form a ball and socket joint enabling the viewing tube to move during operation as a result of vibrations and other movements. The viewing tube may also include one or more lenses positioned within the viewing tube for viewing the turbine components. The lenses may be kept free of contamination by maintaining a higher pressure in the viewing tube than a pressure outside of the viewing tube and enabling gases to pass through an aperture in a cap at a viewing end of the viewing tube.
Estimation of appropriate lubricating film thickness in ceramic-on-ceramic hip prostheses
NASA Astrophysics Data System (ADS)
Tauviqirrahman, M.; Muchammad, Bayuseno, A. P.; Ismail, R.; Saputra, E.; Jamari, J.
2016-04-01
Artificial hip prostheses, consisting of femoral head and acetabular cup are widely used and have affected the lives of many people.However, the primary issue associated with the long term performance of hip prostheses is loosening induced by excessive wear during daily activity. Therefore, an effective lubrication is necessary to significantly decrease the wear. To help understand the lubricating performance of such typical hip joint prostheses, in the present paper a hydrodynamic lubrication model based on Reynolds equationwas introduced. The material pairs of ceramic acetabular cup against ceramic femoral head was investegated.The main aim of this study is to investigate of the effect of loading on the formation of lubricating film thickness.The model of a ball-in-socket configuration was considered assuming that the cup was stationary while the ball was to rotate at a steady angular velocityvarying loads.Based on simulation result, it was found that to promote fluid film lubrication and prevent the contacting components leading to wear, the film thickness of lubricant should be determined carefully based on the load applied. This finding may have useful implication in predicting the failure of lubricating synovial fluid film and wear generation in hip prostheses.
46 CFR 56.30-5 - Welded joints.
Code of Federal Regulations, 2010 CFR
2010-10-01
... systems and should be checked when designing for these systems. (c) Socket welds (Modifies 127.3.3A.). (1) Each socket weld must conform to ASME B16.11 (incorporated by reference; see 46 CFR 56.01-2), to... approximately one-sixteenth inch between the end of the pipe and the bottom of the socket must be provided...
46 CFR 56.30-5 - Welded joints.
Code of Federal Regulations, 2012 CFR
2012-10-01
... systems and should be checked when designing for these systems. (c) Socket welds (Modifies 127.3.3A.). (1) Each socket weld must conform to ASME B16.11 (incorporated by reference; see 46 CFR 56.01-2), to... approximately one-sixteenth inch between the end of the pipe and the bottom of the socket must be provided...
46 CFR 56.30-5 - Welded joints.
Code of Federal Regulations, 2011 CFR
2011-10-01
... systems and should be checked when designing for these systems. (c) Socket welds (Modifies 127.3.3A.). (1) Each socket weld must conform to ASME B16.11 (incorporated by reference; see 46 CFR 56.01-2), to... approximately one-sixteenth inch between the end of the pipe and the bottom of the socket must be provided...
46 CFR 56.30-5 - Welded joints.
Code of Federal Regulations, 2013 CFR
2013-10-01
... systems and should be checked when designing for these systems. (c) Socket welds (Modifies 127.3.3A.). (1) Each socket weld must conform to ASME B16.11 (incorporated by reference; see 46 CFR 56.01-2), to... approximately one-sixteenth inch between the end of the pipe and the bottom of the socket must be provided...
46 CFR 56.30-5 - Welded joints.
Code of Federal Regulations, 2014 CFR
2014-10-01
... systems and should be checked when designing for these systems. (c) Socket welds (Modifies 127.3.3A.). (1) Each socket weld must conform to ASME B16.11 (incorporated by reference; see 46 CFR 56.01-2), to... approximately one-sixteenth inch between the end of the pipe and the bottom of the socket must be provided...
... the opening at the end of the shoulder blade, called the socket. This type of joint allows ... head. The socket part (glenoid) of your shoulder blade will be replaced with a smooth plastic shell ( ...
Vibrating fuel grapple. [LMFBR
Chertock, A.J.; Fox, J.N.; Weissinger, R.B.
A reactor refueling method is described which utilizes a vibrating fuel grapple for removing spent fuel assemblies from a reactor core. It incorporates a pneumatic vibrator in the grapple head which allows additional withdrawal capability without exceeding the allowable axial force limit. The only moving part in the vibrator is a steel ball, pneumatically driven by a gas, such as argon, around a track, with centrifugal force created by the ball being transmitted through the grapple to the assembly handling socket.
Ball-and-Socket-Bearing Wear Test
NASA Technical Reports Server (NTRS)
Graham, W. G.
1984-01-01
Series of experiments to measure wear life of spherical bearing summarized. Report designed to establish clearance, contour, finish, and lubricant parameters for highly-loaded, compact plain spherical bearing. Information useful in design of bearings for helicopter control linkages, business machines, nuclear reactor, and rotor bearings.
Analysis on Sealing Reliability of Bolted Joint Ball Head Component of Satellite Propulsion System
NASA Astrophysics Data System (ADS)
Guo, Tao; Fan, Yougao; Gao, Feng; Gu, Shixin; Wang, Wei
2018-01-01
Propulsion system is one of the important subsystems of satellite, and its performance directly affects the service life, attitude control and reliability of the satellite. The Paper analyzes the sealing principle of bolted joint ball head component of satellite propulsion system and discuss from the compatibility of hydrazine anhydrous and bolted joint ball head component, influence of ground environment on the sealing performance of bolted joint ball heads, and material failure caused by environment, showing that the sealing reliability of bolted joint ball head component is good and the influence of above three aspects on sealing of bolted joint ball head component can be ignored.
Some aspects of frictional measurements in hip joint simulators.
Unsworth, Anthony
2016-05-01
The measurement of friction in artificial hip joints can lead to the knowledge of the lubrication mechanisms occurring in the joints. However, the measurement of friction, particularly in spherical contacts, is not always straightforward. The important loading and kinematic features must be appropriate and the friction must be measured in the correct plane. Even defining a coefficient of friction is difficult with spherical contacts as friction acts at different moment arms throughout the contact area. Thus, the generated frictional torques depend on the pressure distribution of the contact and the moment arms at which this pressure acts. The pressure distribution depends on the material properties, the surface entraining velocities, the joint diameters, and the clearance between the two surfaces of the ball and socket joint. Equally measuring friction is very taxing for machines which are applying very high loads. Slight misalignments of the application of these loads can produce torques which are very much greater than the frictional torques that we are trying to measure. This article attempts to share the thoughts behind over 40 years of measuring friction in artificial joints using the Durham Friction Simulators. This has led to accrued consistency of measurement and a robust scientific design rationale to understand the nature of friction in these spherical contacts. It also impacts on how to obtain accurate measurements as well as on the understanding of where the difficult issues lie and how to overcome them. © IMechE 2016.
A bi-articular model for scapular-humeral rhythm reconstruction through data from wearable sensors.
Lorussi, Federico; Carbonaro, Nicola; De Rossi, Danilo; Tognetti, Alessandro
2016-04-23
Patient-specific performance assessment of arm movements in daily life activities is fundamental for neurological rehabilitation therapy. In most applications, the shoulder movement is simplified through a socket-ball joint, neglecting the movement of the scapular-thoracic complex. This may lead to significant errors. We propose an innovative bi-articular model of the human shoulder for estimating the position of the hand in relation to the sternum. The model takes into account both the scapular-toracic and gleno-humeral movements and their ratio governed by the scapular-humeral rhythm, fusing the information of inertial and textile-based strain sensors. To feed the reconstruction algorithm based on the bi-articular model, an ad-hoc sensing shirt was developed. The shirt was equipped with two inertial measurement units (IMUs) and an integrated textile strain sensor. We built the bi-articular model starting from the data obtained in two planar movements (arm abduction and flexion in the sagittal plane) and analysing the error between the reference data - measured through an optical reference system - and the socket-ball approximation of the shoulder. The 3D model was developed by extending the behaviour of the kinematic chain revealed in the planar trajectories through a parameter identification that takes into account the body structure of the subject. The bi-articular model was evaluated in five subjects in comparison with the optical reference system. The errors were computed in terms of distance between the reference position of the trochlea (end-effector) and the correspondent model estimation. The introduced method remarkably improved the estimation of the position of the trochlea (and consequently the estimation of the hand position during reaching activities) reducing position errors from 11.5 cm to 1.8 cm. Thanks to the developed bi-articular model, we demonstrated a reliable estimation of the upper arm kinematics with a minimal sensing system suitable for daily life monitoring of recovery.
24 CFR 3280.605 - Joints and connections.
Code of Federal Regulations, 2010 CFR
2010-04-01
... watertight for the pressures required under testing procedures. (1) Assembling of pipe. All joints and... or welding sockets of each fitting. Pipe threads and slip joints shall not be wrapped with string...
46 CFR 154.528 - Piping joints: Flange type.
Code of Federal Regulations, 2014 CFR
2014-10-01
... following types: (1) Welding neck. (2) Slip-on. (3) Socket weld. (b) If the piping is designed for a... nominal pipe size is 100 mm (4 in.) or less; (2) Socket weld, if the nominal pipe size is 50 mm (2 in.) or...
46 CFR 154.528 - Piping joints: Flange type.
Code of Federal Regulations, 2011 CFR
2011-10-01
... following types: (1) Welding neck. (2) Slip-on. (3) Socket weld. (b) If the piping is designed for a... nominal pipe size is 100 mm (4 in.) or less; (2) Socket weld, if the nominal pipe size is 50 mm (2 in.) or...
46 CFR 154.528 - Piping joints: Flange type.
Code of Federal Regulations, 2012 CFR
2012-10-01
... following types: (1) Welding neck. (2) Slip-on. (3) Socket weld. (b) If the piping is designed for a... nominal pipe size is 100 mm (4 in.) or less; (2) Socket weld, if the nominal pipe size is 50 mm (2 in.) or...
46 CFR 154.528 - Piping joints: Flange type.
Code of Federal Regulations, 2013 CFR
2013-10-01
... following types: (1) Welding neck. (2) Slip-on. (3) Socket weld. (b) If the piping is designed for a... nominal pipe size is 100 mm (4 in.) or less; (2) Socket weld, if the nominal pipe size is 50 mm (2 in.) or...
Karjalainen, Teemu; Pamilo, Konsta; Reito, Aleksi
2018-04-21
We describe 2 cases of articulation-related failures resulting in revision surgery after a Motec total wrist arthroplasty: one with an adverse reaction to metal debris and the other with an adverse reaction to polyether ether ketone. In the first patient, blood cobalt and chrome levels were elevated and magnetic resonance imaging showed clear signs of a pseudotumor. The other patient had an extensive release of polyether ether ketone particles into the surrounding synovia due to adverse wear conditions in the cup, leading to the formation of a fluid-filled cyst sac with a black lining and diffuse lymphocyte-dominated inflammation in the synovia. We recommend regular follow-up including x-rays, monitoring of cobalt and chrome ion levels, and a low threshold for cross-sectional imaging in patients who have undergone total wrist arthroplasty with a Motec joint prosthesis. Wear-related problems can also develop in implants in which polyether ether ketone is the bulk material. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Does location of rotation center in artificial disc affect cervical biomechanics?
Mo, Zhongjun; Zhao, Yanbin; Du, Chengfei; Sun, Yu; Zhang, Ming; Fan, Yubo
2015-04-15
A 3-dimensional finite element investigation. To compare the biomechanical performances of different rotation centers (RCs) in the prevalent artificial cervical discs. Various configurations are applied in artificial discs. Design parameters may influence the biomechanics of implanted spine. The RC is a primary variation in the popular artificial discs. Implantation of 5 prostheses was simulated at C5-C6 on the basis of a validated finite element cervical model (C3-C7). The prostheses included ball-in-socket design with a fixed RC located on the inferior endplate (BS-FI) and on the superior endplate (BS-FS), with a mobile RC at the inferior endplate (BS-MI), dual articulation with a mobile RC between the endplates (DA-M), and sliding articulation with various RCs (SA-V). The spinal motions in flexion and extension served as a displacement loading at the C3 vertebrae. Total disc replacements reduced extension moment. The ball-in-socket designs required less flexion moment, whereas the flexion stiffness of the spines with DA-M and SA-V was similar to that of the healthy model. The contributions of the implanted level to the global motions increased in the total disc replacements, except in the SA-V and DA-M models (in flexion). Ball-in-socket designs produced severe stress distributions in facet cartilage, whereas DA-M and SA-V produced more severe stress distribution on the bone-implant interface. Cervical stability was extremely affected in extension and partially affected in flexion by total disc replacement. With the prostheses with mobile RC, cervical curvature was readjusted under a low follower load. The SA-V and BS-FS designs exhibited better performances in the entire segmental stiffness and in the stability of the operative level than the BS-MI and BS-FI designs in flexion. The 5 designs demonstrated varying advantages relative to the stress distribution in the facet cartilages and on the bone-implant interface. 5.
A study on fatigue strength reduction factor for small diameter socket welded pipe joints
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higuchi, Makoto; Nakagawa, Akira; Hayashi, Makoto
1996-12-01
Factors that may exert influence on the fatigue strength of small diameter socket welded joints of nominal diameter in the 20--50 mm range have been investigated by the fully reversed four-point bending fatigue test with the material, diameter, pipe schedule, throat depth, bead shape, slip-on gap, and root defect as the testing parameters. The fatigue strength of socket joints depended acutely on the diameter. When the diameter is large, the fatigue strength tended to be low and the fracture is of the root-failure mode; when it is small, on the other hand, the fatigue strength is high and the fracturemore » is of the toe-failure mode. Stainless steel proved to be superior to carbon steel; it gave rise to 1.37 times the fatigue strength of the latter for socket joints of nominal diameter 50 mm; the fatigue strength reduction factor determined at 10{sup 7} cycles with respect to the fatigue strength of smooth base metal in the fully reversed fatigue was about 4 for stainless steel and about 5 for carbon steel. The fatigue strength was higher, the larger the Sche number (i.e., the thicker the pipe wall); it was improved markedly by placing one final refinement pass on the toe or by eliminating the slip-on gap. An empirical formula relating the size of the root defect to the fatigue strength reduction has been proposed.« less
Circuit reliability boosted by soldering pins of disconnect plugs to sockets
NASA Technical Reports Server (NTRS)
Pierce, W. B.
1964-01-01
Where disconnect pins must be used for wiring and testing a circuit, improved system reliability is obtained by making a permanent joint between pins and sockets of the disconnect plug. After the circuit has been tested, contact points may be fused through soldering, brazing, or welding.
On the dynamics of a human body model.
NASA Technical Reports Server (NTRS)
Huston, R. L.; Passerello, C. E.
1971-01-01
Equations of motion for a model of the human body are developed. Basically, the model consists of an elliptical cylinder representing the torso, together with a system of frustrums of elliptical cones representing the limbs. They are connected to the main body and each other by hinges and ball and socket joints. Vector, tensor, and matrix methods provide a systematic organization of the geometry. The equations of motion are developed from the principles of classical mechanics. The solution of these equations then provide the displacement and rotation of the main body when the external forces and relative limb motions are specified. Three simple example motions are studied to illustrate the method. The first is an analysis and comparison of simple lifting on the earth and the moon. The second is an elementary approach to underwater swimming, including both viscous and inertia effects. The third is an analysis of kicking motion and its effect upon a vertically suspended man such as a parachutist.
Fully redundant mechanical release actuator
NASA Technical Reports Server (NTRS)
Lucy, Melvin H. (Inventor)
1987-01-01
A system is described for performing a mechanical release function exhibiting low shock. This system includes two pyrotechnic detents fixed mounted in opposing axial alignment within a cylindrical housing having two mechanical bellows. Two mechanical bellow assemblies, each having one end hermetically bonded to the housing and the other to the respective actuator pin extending from either end of the housing, ensure that all outgassing and contamination from the operation of the pyrotechnic devices will be contained within the housing and bellows. The pin on one end of the assembly is fixed mounted and supported, via a bolt or ball-and-socket joint so that when the charge corresponding to that pin ignites, the entire assembly will exhibit rectilinear movement, including the opposing pin providing the unlatching motion. The release detent pin is supported by a linear bearing and when its corresponding pyrotechnic charge ignites the pin is retracted within the housing producing the same unlatching motion without movement of the entire assembly, thus providing complete mechanical, electrical and pyrotechnic redundancy for the unlatching pin.
21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...
21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...
21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...
21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...
21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...
Double slotted socket spherical joint
Bieg, Lothar F.; Benavides, Gilbert L.
2001-05-22
A new class of spherical joints is disclosed. These spherical joints are capable of extremely large angular displacements (full cone angles in excess of 270.degree.), while exhibiting no singularities or dead spots in their range of motion. These joints can improve or simplify a wide range of mechanical devices.
NASA Astrophysics Data System (ADS)
Zhou, M. B.; Ma, X.; Zhang, X. P.
2012-11-01
The microstructure of microscale solder interconnects and soldering defects have long been known to have a significant influence on the reliability of electronic packaging, and both are directly related to the solidification behavior of the undercooled solder. In this study, the undercooling behavior and solidification microstructural evolution of Sn-3.0Ag-0.5Cu solder balls with different diameters (0.76 mm, 0.50 mm, and 0.30 mm) and the joints formed by soldering these balls on Cu open pads of two diameters (0.48 mm and 0.32 mm) on a printed circuit board (PCB) substrate were characterized by differential scanning calorimetry (DSC) incorporated into the reflow process. Results show that the decrease in diameter of the solder balls leads to an obvious increase in the undercooling of the balls, while the undercooling of the solder joints shows a dependence on both the diameter of the solder balls and the diameter ratio of solder ball to Cu pad (i.e., D s/ D p), and the diameter of the solder balls has a stronger influence on the undercooling of the joints than the dimension of the Cu pad. Coarse primary intermetallic compound (IMC) solidification phases were formed in the smaller solder balls and joints. The bulk Ag3Sn IMC is the primary solidification phase in the as-reflowed solder balls. Due to the interfacial reaction and dissolution of Cu atoms into the solder matrix, the primary Ag3Sn phase can be suppressed and the bulk Cu6Sn5 IMC is the only primary solidification phase in the as-reflowed solder joints.
Bhattacharjee, Kasturi; Bhattacharjee, Harsha; Kuri, Ganesh; Das, Jayanta Kr; Dey, Debleena
2014-01-01
Purpose: The purpose of our study is to present a surgical technique of primary porous orbital ball implantation with overlying mucus membrane graft (MMG) for reconstruction of severely contracted socket and to evaluate prosthesis retention and motility in comparison to dermis fat graft (DFG). Study Design: Prospective comparative study. Materials and Methods: A total of 24 patients of severe socket contracture (Grade 2-4 Krishna's classification) were subdivided into two groups, 12 patients in each group. In Group I, DFG have been used for reconstruction. In Group II, porous polyethylene implant with MMG has been used as a primary procedure for socket reconstruction. In Group I DFG was carried out in usual procedure. In case of Group II, vascularized scar tissues were separated 360° and were fashioned into four strips. A scleral capped porous polyethylene implant was placed in the intraconal space and four strips of scar tissue were secured to the scleral cap and extended part overlapped the implant to make a twofold barrier between the implant and MMG. Patients were followed-up as per prefixed proforma. Prosthesis motility and retention between the two groups were measured. Results: In Group I, four patients had recurrence of contracture with fall out of prosthesis. In Group II stable reconstruction was achieved in all the patients. In terms of prosthesis motility, maximum in Group I was 39.2% and Group II, was 59.3%. The difference in prosthesis retention (P = 0.001) and motility (P = 0.004) between the two groups was significant. Conclusion: Primary socket reconstruction with porous orbital implant and MMG for severe socket contracture is an effective method in terms of prosthesis motility and prosthesis retention. PMID:24618485
Design and preliminary biomechanical analysis of artificial cervical joint complex.
Jian, Yu; Lan-Tao, Liu; Zhao, Jian-ning; Jian-ning, Zhao
2013-06-01
To design an artificial cervical joint complex (ACJC) prosthesis for non-fusion reconstruction after cervical subtotal corpectomy, and to evaluate the biomechanical stability, preservation of segment movements and influence on adjacent inter-vertebral movements of this prosthesis. The prosthesis was composed of three parts: the upper/lower joint head and the middle artificial vertebrae made of Cobalt-Chromium-Molybdenum (Co-Cr-Mo) alloy and polyethylene with a ball-and-socket joint design resembling the multi-axial movement in normal inter-vertebral spaces. Biomechanical tests of intact spine (control), Orion locking plate system and ACJC prosthesis were performed on formalin-fixed cervical spine specimens from 21 healthy cadavers to compare stability, range of motion (ROM) of the surgical segment and ROM of adjacent inter-vertebral spaces. As for stability of the whole lower cervical spine, there was no significant difference of flexion, extension, lateral bending and torsion between intact spine group and ACJC prosthesis group. As for segment movements, difference in flexion, lateral bending or torsion between ACJC prosthesis group and control group was not statistically significant, while ACJC prosthesis group showed an increase in extension (P < 0.05) compared to that of the control group. In addition, ACJC prosthesis group demonstrated better flexion, extension and lateral bending compared to those of Orion plating system group (P < 0.05). Difference in adjacent inter-vertebral ROM of the ACJC prosthesis group was not statistically significant compared to that of the control group. After cervical subtotal corpectomy, reconstruction with ACJC prosthesis not only obtained instant stability, but also reserved segment motions effectively, without abnormal gain of mobility at adjacent inter-vertebral spaces.
49 CFR 572.9 - Lumbar spine, abdomen, and pelvis.
Code of Federal Regulations, 2013 CFR
2013-10-01
...″ cap screw holes and attach the front mounting at the femur axial rotation joint. Tighten the mountings... socket joint to 240 inch-pounds torque. (3) Flex the thorax forward 50° and then rearward as necessary to...
49 CFR 572.9 - Lumbar spine, abdomen, and pelvis.
Code of Federal Regulations, 2010 CFR
2010-10-01
...″ cap screw holes and attach the front mounting at the femur axial rotation joint. Tighten the mountings... socket joint to 240 inch-pounds torque. (3) Flex the thorax forward 50° and then rearward as necessary to...
49 CFR 572.9 - Lumbar spine, abdomen, and pelvis.
Code of Federal Regulations, 2012 CFR
2012-10-01
...″ cap screw holes and attach the front mounting at the femur axial rotation joint. Tighten the mountings... socket joint to 240 inch-pounds torque. (3) Flex the thorax forward 50° and then rearward as necessary to...
49 CFR 572.9 - Lumbar spine, abdomen, and pelvis.
Code of Federal Regulations, 2011 CFR
2011-10-01
...″ cap screw holes and attach the front mounting at the femur axial rotation joint. Tighten the mountings... socket joint to 240 inch-pounds torque. (3) Flex the thorax forward 50° and then rearward as necessary to...
49 CFR 572.9 - Lumbar spine, abdomen, and pelvis.
Code of Federal Regulations, 2014 CFR
2014-10-01
...″ cap screw holes and attach the front mounting at the femur axial rotation joint. Tighten the mountings... socket joint to 240 inch-pounds torque. (3) Flex the thorax forward 50° and then rearward as necessary to...
Jimenez-Sandoval, Pedro; Vique-Sanchez, Jose Luis; Hidalgo, Marisol López; Velazquez-Juarez, Gilberto; Diaz-Quezada, Corina; Arroyo-Navarro, Luis Fernando; Moran, Gabriela Montero; Fattori, Juliana; Jessica Diaz-Salazar, A; Rudiño-Pinera, Enrique; Sotelo-Mundo, Rogerio; Figueira, Ana Carolina Migliorini; Lara-Gonzalez, Samuel; Benítez-Cardoza, Claudia G; Brieba, Luis G
2017-11-01
The protozoan parasite Trichomonas vaginalis contains two nearly identical triosephosphate isomerases (TvTIMs) that dissociate into stable monomers and dimerize upon substrate binding. Herein, we compare the role of the "ball and socket" and loop 3 interactions in substrate assisted dimer assembly in both TvTIMs. We found that point mutants at the "ball" are only 39 and 29-fold less catalytically active than their corresponding wild-type counterparts, whereas Δloop 3 deletions are 1502 and 9400-fold less active. Point and deletion mutants dissociate into stable monomers. However, point mutants assemble as catalytic competent dimers upon binding of the transition state substrate analog PGH, whereas loop 3 deletions remain monomeric. A comparison between crystal structures of point and loop 3 deletion monomeric mutants illustrates that the catalytic residues in point mutants and wild-type TvTIMs are maintained in the same orientation, whereas the catalytic residues in deletion mutants show an increase in thermal mobility and present structural disorder that may hamper their catalytic role. The high enzymatic activity present in monomeric point mutants correlates with the formation of dimeric TvTIMs upon substrate binding. In contrast, the low activity and lack of dimer assembly in deletion mutants suggests a role of loop 3 in promoting the formation of the active site as well as dimer assembly. Our results suggest that in TvTIMs the active site is assembled during dimerization and that the integrity of loop 3 and ball and socket residues is crucial to stabilize the dimer. Copyright © 2017 Elsevier B.V. All rights reserved.
Analysis of the Hexapod Work Space using integration of a CAD/CAE system and the LabVIEW software
NASA Astrophysics Data System (ADS)
Herbuś, K.; Ociepka, P.
2015-11-01
The paper presents the problems related to the integration of a CAD/CAE system with the LabVIEW software. The purpose of the integration is to determine the workspace of a hexapod model basing on a mathematical model describing it motion. In the first stage of the work concerning the integration task the 3D model to simulate movements of a hexapod was elaborated. This phase of the work was done in the “Motion Simulation” module of the CAD/CAE/CAM Siemens NX system. The first step was to define the components of the 3D model in the form of “links”. Individual links were defined according to the nature of the hexapod elements action. In the model prepared for movement simulation were created links corresponding to such elements as: electric actuator, top plate, bottom plate, ball-and-socket joint, toggle joint Phillips. Then were defined the constraints of the “joint” type (e.g.: revolute joint, slider joint, spherical joint) between the created component of the “link” type, so that the computer simulation corresponds to the operation of a real hexapod. The next stage of work included implementing the mathematical model describing the functioning of a hexapod in the LabVIEW software. At this stage, particular attention was paid to determining procedures for integrating the virtual 3D hexapod model with the results of calculations performed in the LabVIEW. The results relate to specific values of the jump of electric actuators depending on the position of the car on the hexapod. The use of integration made it possible to determine the safe operating space of a stationary hexapod taking into consideration the security of a person in the driving simulator designed for the disabled.
Mahrous, Ahmed I; Aldawash, Hussien A; Soliman, Tarek A; Banasr, Fahad H; Abdelwahed, Ahmed
2015-01-01
Background: This study was conducted to compare and evaluate the effect of two different attachments (locator attachment and ball and socket [B&S] attachment) on implants and natural abutments supporting structures, in cases of limited inter-arch spaces in mandibular Kennedy Class I implant supported removable partial over dentures by measuring the bone height changes through the cone beam radiographic technology. Materials and Methods: Two implants were positioned in the first or second molar area following the two-stage surgical protocol. Two equal groups were divided ten for each: Group I: Sides were the placed implants restored by the locator attachment. Group II: The other sides, implants were restored by B&S attachment. Evaluation of the implants and main abutments supporting structures of each group was done at the time of removable partial over denture insertion, 6, 12 and 18 months by measuring the bone height changes using cone beam computed tomography. Results: Implants with locator attachment showed marginal bone height better effects on implants and main abutments supporting structures. Conclusion: Implants restored by locator attachment shows better effects on bone of both main natural abutments and implant than those restored with ball and socket. PMID:26028894
Steady Motions of Rigid Body Satellites in a Central Gravitational Field
1993-12-01
been explored for several centuries. Orbiting bodies investigated include point masses, spheres, cylinders, rods, ball-and-socket connected objects...of the satellite model relative to its orbit radius could lead to 5 its treatment as a point mass, doing so would prevent analysis of satellite...8217 librational ’ motion ... and internal elastic forces in the structure balance the orbital dynamic accelerations tending to separate masses orbiting at
Pelvic rotation torque during fast-pitch softball hitting under three ball height conditions.
Iino, Yoichi; Fukushima, Atsushi; Kojima, Takeji
2014-08-01
The purpose of this study was to investigate the relevance of hip joint angles to the production of the pelvic rotation torque in fast-pitch softball hitting and to examine the effect of ball height on this production. Thirteen advanced female softball players hit stationary balls at three different heights: high, middle, and low. The pelvic rotation torque, defined as the torque acting on the pelvis through the hip joints about the pelvic superior-inferior axis, was determined from the kinematic and force plate data using inverse dynamics. Irrespective of the ball heights, the rear hip extension, rear hip external rotation, front hip adduction, and front hip flexion torques contributed to the production of pelvic rotation torque. Although the contributions of the adduction and external rotation torques at each hip joint were significantly different among the ball heights, the contributions of the front and rear hip joint torques were similar among the three ball heights owing to cancelation of the two torque components. The timings of the peaks of the hip joint torque components were significantly different, suggesting that softball hitters may need to adjust the timings of the torque exertions fairly precisely to rotate the upper body effectively.
NASA Technical Reports Server (NTRS)
Robinson, B. A.; Foster, C. L.
1986-01-01
A series of torque tests were performed on four flight-type hex ball universal joints in order to characterize and determine the actual load-carrying capability of this device. The universal joint is a part of manual actuation rods for scientific instruments within the Hubble Space Telescope. It was found that the hex ball will bind slightly during the initial load application. This binding did not affect the function of the universal joint, and the units would wear-in after a few additional loading cycles. The torsional yield load was approximately 50 ft-lb, and was consistent among the four test specimens. Also, the torque required to cause complete failure exceeded 80 ft-lb. It is concluded that the hex ball universal joint is suitable for its intended applications.
Terheyden, H; Mühlendyck, C; Feldmann, H; Ludwig, K; Härle, F
1999-02-01
Besides rigid fixation, lag screws have distinct advantages compared with plates in appropriate indications in mandibular fractures. However, in current lag screw systems, the relatively small area of the screw head has to transfer the tensile force which can exceed 1000 N in the symphysis, to the thin cortical bone plate. Countersinking, which is obligatory in most systems, will weaken the cortical plate. Finite element analysis (FEA) revealed that load in this situation can exceed the normal tensile strength of metal and bone. Consequently, a new washer was constructed which both increased the supporting surface and did not require countersinking. The washer is self adapting (SAW) to the cortical plate in a defined position, forming a ball and socket joint with the screw head. Using the FEA model, a ten-fold reduction in load on bone and metal was observed with the new washer. In a miniature pig mandibular symphysis fracture model, the clinical applicability and a favourable histological reaction were demonstrated, compared with conventional lag screw designs.
... Hypermobility syndrome Images Hypermobile joints References Ball JW, Dains JE, Flynn JA, Solomon BS, Stewart RW. Musculoskeletal system. In: Ball JW, Dains JE, Flynn JA, Solomon BS, Stewart RW, eds. ...
Simulation of Blast Loading on an Ultrastructurally-based Computational Model of the Ocular Lens
2016-12-01
organelles. Additionally, the cell membranes demonstrated the classic ball-and-socket loops . For the SEM images, they were placed in two fixatives and mounted...considered (fibrous network and matrix), both components are modelled using a hyper - elastic framework, and the resulting constitutive model is embedded in a...within the framework of hyper - elasticity). Full details on the linearization procedures that were adopted in these previous models or the convergence
Identification of temporal pathomechanical factors during the tennis serve.
Martin, Caroline; Kulpa, Richard; Ropars, Mickaël; Delamarche, Paul; Bideau, Benoit
2013-11-01
The purpose of this study was twofold: (a) to measure the effects of temporal parameters on both ball velocity and upper limb joint kinetics to identify pathomechanical factors during the tennis serve and (b) to validate these pathomechanical factors by comparing injured and noninjured players. The serves of expert tennis players were recorded with an optoelectronic motion capture system. These experts were then followed during two seasons to identify overuse injuries of the upper limb. Correlation coefficients assessed the relationships between temporal parameters, ball velocity, and peaks of upper limb joint kinetics to identify pathomechanical factors. Temporal parameters and ball velocity were compared between injured and noninjured groups. Temporal pathomechanical factors were identified. The timings of peak angular velocities of pelvis longitudinal rotation, upper torso longitudinal rotation, trunk sagittal rotation, and trunk transverse rotation and the duration between instants of shoulder horizontal adduction and external rotation were significantly related to upper limb joint kinetics and ball velocity. Injured players demonstrated later timings of trunk rotations, improper differences in time between instants of shoulder horizontal adduction and external rotation, lower ball velocities, and higher joint kinetics. The findings of this study imply that improper temporal mechanics during the tennis serve can decrease ball velocity, increase upper limb joint kinetics, and thus possibly increase overuse injuries of the upper limb.
Langley Research Center Standard for the Evaluation of Socket Welds
NASA Technical Reports Server (NTRS)
Berry, R. F., Jr.
1985-01-01
A specification utilized for the nondestructive evaluation of socket type pipe joints at Langley Research Center (LaRC) is discussed. The scope of hardware shall include, but is not limited to, all common pipe fittings: tees, elbows, couplings, caps, and so forth, socket type flanges, unions, and valves. In addition, the exterior weld of slip on flanges shall be inspected using this specification. At the discretion of the design engineer, standard practice engineer, Fracture Mechanics Engineering Section, Pressure Systems Committee, or other authority, four nondestructive evaluation techniques may be utilized exclusively, or in combination, to inspect socket type welds. These techniques are visual, radiographic, magnetic particle, and dye penetrant. Under special circumstances, other techniques (such as eddy current or ultrasonics) may be required and their application shall be guided by the appropriate sections of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (B&PVC).
Controversies In The Surgical Management Of Shoulder Instability: Associated Soft Tissue Procedures
Moros Marco, Santos; Ávila Lafuente, José Luis; Ruiz Ibán, Miguel Angel; Diaz Heredia, Jorge
2017-01-01
Background: The glenohumeral joint is a ball-and-socket joint that is inherently unstable and thus, susceptible to dislocation. The traditional and most common anatomic finding is the Bankart lesion (anterior-inferior capsule labral complex avulsion), but there is a wide variety of anatomic alterations that can cause shoulder instability or may be present as a concomitant injury or in combination, including bone loss (glenoid or humeral head), complex capsule-labral tears, rotator cuff tears, Kim´s lesions (injuries to the posterior-inferior labrum) and rotator interval pathology. Methods: A review of articles related to shoulder anatomy and soft tissue procedures that are performed during shoulder instability arthroscopic management was conducted by querying the Pubmed database and conclusions and controversies regarding this injury were exposed. Results: Due to the complex anatomy of the shoulder and the large range of movement of this joint, a wide variety of anatomic injuries and conditions can lead to shoulder instability, specially present in young population. Recognizing and treating all of them including Bankart repair, capsule-labral plicatures, SLAP repair, circumferential approach to pan-labral lesions, rotator interval closure, rotator cuff injuries and HAGL lesion repair is crucial to achieve the goal of a stable, full range of movement and not painful joint. Conclusion: Physicians must be familiarized with all the lesions involved in shoulder instability, and should be able to recognize and subsequently treat them to achieve the goal of a stable non-painful shoulder. Unrecognized or not treated lesions may result in recurrence of instability episodes and pain while overuse of some of the techniques previously described can lead to stiffness, thus the importance of an accurate diagnosis and treatment when facing a shoulder instability. PMID:28979603
Controversies In The Surgical Management Of Shoulder Instability: Associated Soft Tissue Procedures.
Marco, Santos Moros; Lafuente, José Luis Ávila; Ibán, Miguel Angel Ruiz; Heredia, Jorge Diaz
2017-01-01
The glenohumeral joint is a ball-and-socket joint that is inherently unstable and thus, susceptible to dislocation. The traditional and most common anatomic finding is the Bankart lesion (anterior-inferior capsule labral complex avulsion), but there is a wide variety of anatomic alterations that can cause shoulder instability or may be present as a concomitant injury or in combination, including bone loss (glenoid or humeral head), complex capsule-labral tears, rotator cuff tears, Kim´s lesions (injuries to the posterior-inferior labrum) and rotator interval pathology. A review of articles related to shoulder anatomy and soft tissue procedures that are performed during shoulder instability arthroscopic management was conducted by querying the Pubmed database and conclusions and controversies regarding this injury were exposed. Due to the complex anatomy of the shoulder and the large range of movement of this joint, a wide variety of anatomic injuries and conditions can lead to shoulder instability, specially present in young population. Recognizing and treating all of them including Bankart repair, capsule-labral plicatures, SLAP repair, circumferential approach to pan-labral lesions, rotator interval closure, rotator cuff injuries and HAGL lesion repair is crucial to achieve the goal of a stable, full range of movement and not painful joint. Physicians must be familiarized with all the lesions involved in shoulder instability, and should be able to recognize and subsequently treat them to achieve the goal of a stable non-painful shoulder. Unrecognized or not treated lesions may result in recurrence of instability episodes and pain while overuse of some of the techniques previously described can lead to stiffness, thus the importance of an accurate diagnosis and treatment when facing a shoulder instability.
Biotribology of artificial hip joints
Di Puccio, Francesca; Mattei, Lorenza
2015-01-01
Hip arthroplasty can be considered one of the major successes of orthopedic surgery, with more than 350000 replacements performed every year in the United States with a constantly increasing rate. The main limitations to the lifespan of these devices are due to tribological aspects, in particular the wear of mating surfaces, which implies a loss of matter and modification of surface geometry. However, wear is a complex phenomenon, also involving lubrication and friction. The present paper deals with the tribological performance of hip implants and is organized in to three main sections. Firstly, the basic elements of tribology are presented, from contact mechanics of ball-in-socket joints to ultra high molecular weight polyethylene wear laws. Some fundamental equations are also reported, with the aim of providing the reader with some simple tools for tribological investigations. In the second section, the focus moves to artificial hip joints, defining materials and geometrical properties and discussing their friction, lubrication and wear characteristics. In particular, the features of different couplings, from metal-on-plastic to metal-on-metal and ceramic-on-ceramic, are discussed as well as the role of the head radius and clearance. How friction, lubrication and wear are interconnected and most of all how they are specific for each loading and kinematic condition is highlighted. Thus, the significant differences in patients and their lifestyles account for the high dispersion of clinical data. Furthermore, such consideration has raised a new discussion on the most suitable in vitro tests for hip implants as simplified gait cycles can be too far from effective implant working conditions. In the third section, the trends of hip implants in the years from 2003 to 2012 provided by the National Joint Registry of England, Wales and Northern Ireland are summarized and commented on in a discussion. PMID:25621213
Multi-pelvis characterisation of articular cartilage geometry.
Gillard, Faye C; Dickinson, Alexander S; Schneider, Urs; Taylor, Andrew C; Browne, Martin
2013-12-01
The shape of the acetabular cartilage follows the contact stress distribution across the joint. Accurate characterisation of this geometry may be useful for the development of acetabular cup devices that are more biomechanically compliant. In this study, the geometry of the acetabular cartilage was characterised by taking plaster moulds of the acetabulum from 24 dry bone human pelvises and digitising the mould shapes using a three-dimensional laser scanner. The articular bone surface geometry was analysed, and the shape of the acetabulum was approximated by fitting a best-fit sphere. To test the hypothesis that the acetabulum is non-spherical, a best-fit ellipsoid was also fitted to the geometry. In each case, points around the acetabular notch edge that disclosed the articular surface geometry were identified, and vectors were drawn between these and the best-fit sphere or ellipsoid centre. The significantly larger z radii (into the pole) of the ellipsoids indicated that the acetabulum was non-spherical and could imply that the kinematics of the hip joint is more complex than purely rotational motion, and the traditional ball-and-socket replacement may need to be updated to reflect this motion. The acetabular notch edges were observed to be curved, with males exhibiting deeper, wider and shorter notches than females, although the difference was not statistically significant (mean: p = 0.30) and supports the use of non-gender-specific models in anatomical studies.
Code of Federal Regulations, 2013 CFR
2013-01-01
... system joints (in push-pull systems) that are subject to angular motion, except those in ball and roller... in cable control systems. For ball or roller bearings, the approved ratings may not be exceeded...
NASA Astrophysics Data System (ADS)
Harbor, D. J.; Barnhart, W. D.
2017-12-01
The 2013 M7.7 Baluchistan earthquake in southern Pakistan ruptured 200 km of the north-dipping Hoshab reverse fault with dominantly lateral motion, clearly at odds with the regional topography created by previous reverse fault offsets. The kinematics of this earthquake led to the hypotheses that the Hoshab fault may alternatively slip in a reverse and lateral sense (bi-modal slip), and that the southeast Makran rotates as a uniform block around the fault (ball-and-socket rotation). Here, we use river profiles, regional relief, fault locations, and detailed geomorphic maps derived from optical imagery and DEMs to evaluate the recent uplift history of this region. We find that late Cenozoic fault zone geomorphology supports a spatially complex transition from lateral-dominated offsets in the NE to reverse-dominated offsets in the SW. Additionally, fault zone geomorphology suggests that the location of the Hoshab fault itself may change through time, leading to active incision of footwall alluvial fans and pediments. Stream profiles likewise record incision patterns that vary along the Hoshab fault. Incision and deposition in the SW are illustrative of relative footwall subsidence, consistent with recent uplift on the Hoshab fault; whereas incision and deposition in the NE are illustrative of relative footwall uplift consistent with ongoing regional uplift due to ball-and-socket rotations and dominantly lateral offsets along the northern Hoshab fault. The largest streams also record multiple, discrete, base-level drops, including the presence of convex-up river profiles in the hanging wall of the Hoshab fault. These profiles along hanging wall streams highlight a complex spatial and temporal history of reverse offset, lateral channel offset, and base-level resetting in regional streams that are altogether inconsistent with the kinematics of the 2013 earthquake alone, but that are consistent with the bi-modal slip model. Additionally, the evidence of footwall uplift in the NE is consistent with regional uplift due to ball-and-socket rotations superimposed on the Hoshab fault. These results indicate that the styles of fault slip in the Makran change in time and space in response to ongoing convergence and block rotations despite negligible uplift during the 2013 earthquake.
Installation of the Douglas XSB2D-1 in the Test Section of the 40x80 Foot Wind Tunnel at Ames.
1944-06-12
Test section of the Ames 40 x 80 foot wind tunnel with the overhead doors open. XSB2D-1 airplane being lowered onto the struts by the overhead crane. Mechanics and engineers on orchard ladders aligning the model with ball sockets on the struts. The Douglas BTD Destroyer was an American dive/ torpedo bomber developed for the United States Navy during World War II.
Latch fittings for the scientific instruments on the space telescope
NASA Technical Reports Server (NTRS)
Dozier, J. D.; Kaelber, E.
1983-01-01
Latch fittings which kinematically mount the replaceable scientific instruments onto the Space Telescope must maintain precise alignment and thermal stability for on-orbit observations. Design features which are needed to meet stringent criteria include the use of ceramic isolators for thermal and electrical insulation, materials with different coefficients of thermal expansion for athermalization, precision manufacturing procedures, and extremely tight tolerances. A specific latch fitting to be discussed is a ball-and-socket design. In addition, testing, crew aids, and problems will be covered.
Dynamics of small flexible fibers in turbulent channel flow
NASA Astrophysics Data System (ADS)
Marchioli, Cristian; Dotto, Diego; Soldati, Alfredo
2017-11-01
In this paper we investigate the dynamics of small flexible fibers in turbulent channel flow. Our aim is to examine the effect of local shear and turbulence anisotropy on the translation and rotation of fibers with different elongation and inertia. To these aims, we use a Eulerian-Lagrangian approach based on direct numerical simulation of turbulence in the dilute regime, and we model fibers, which are longer than the Kolmogorov scale, as chains of sub-Kolmogorov rods connected through ball-and-socket joints that enable bending and twisting. Velocity, orientation and concentration statistics, extracted from simulations at Reτ = 300 , are presented to give insights into the complex fibers-turbulence interactions that arise when non-sphericity and deformability add to inertial bias. Compared to fibers that translate and rotate as rigid bodies relative to the surrounding fluid, flexible fibers exhibit a stronger tendency to accumulate in the near-wall region, where they are trapped by the same mechanisms that govern preferential concentration of spherical particles. In such region, the mean shear is strong enough to reduce bending and stretch the fibers. Preferential segregation into low-speed streaks and preferential orientation in the mean flow direction are also observed.
The "pseudo-craniovertebral articulation" in the deep-sea fish Stomias boa (Teleostei: Stomiidae).
Schnell, Nalani K; Bernstein, Peter; Maier, Wolfgang
2008-05-01
Many predatory deep-sea fishes show highly specialized modifications of their feeding apparatus, e.g., elongate jaws studded with long daggerlike teeth, often combined with a very distensible stomach, to be capable of swallowing relatively large prey. These striking features can be observed in members of the marine teleost family Stomiidae. The present study gives a detailed morphological description of the mesopelagic predatory fish, Stomias boa, based on a combined approach of clearing and double staining, serial sections and dissection. In this genus, large pads made of dense connective tissue extend from the first enlarged neural arch to the ventral side of the chordal sheath, embracing the prominent exoccipitals and thus constituting a kind of double ball- and socket joint for the head. The notochordal occipito-vertebral gap is enlarged, probably not by loss of vertebral centra as is proposed for other genera of the stomiid family, e.g., in Astronesthes or Photostomias. We conclude that this "pseudo-craniovertebral articulation" serves as a functional substitute for the absent vertebrae and strengthens the flexible, anterior part of the vertebral column during extreme dorsal expansion of the gape during prey capture and swallowing. (c) 2007 Wiley-Liss, Inc.
Flare angles measured with ball gage
NASA Technical Reports Server (NTRS)
Cleghorn, D.; Wall, W. A.
1968-01-01
Precision tungsten carbide balls measure the internal angle of flared joints. Measurements from small and large balls in the flare throat to an external reference point are made. The difference in distances and diameters determine the average slope of the flare between the points of ball contact.
NASA Astrophysics Data System (ADS)
Pepe, Fabrizio; Corradino, Marta; Parrino, Nicolò; Besio, Giovanni; Presti, Valeria Lo; Renda, Pietro; Calcagnile, Lucio; Quarta, Gianluca; Sulli, Attilio; Antonioli, Fabrizio
2018-02-01
Boulders are frequently dislodged from rock platforms, transported and deposited along coastal zones by high-magnitude storm waves or tsunamis. Their size and shape are often controlled by the thickness of bedding planes as well as by high-angle to bedding fracture network. We investigate these processes along two coastal areas of Favignana Island by integrating geological data for 81 boulders, 49 rupture surfaces (called sockets) and fracture orientation and spacing with four radiocarbon dates, numerical hydrodynamic analysis, and hindcast numerical simulation data. Boulders are scattered along the carbonate platform as isolated blocks or in small groups, which form, as a whole, a discontinuous berm. Underwater surveys also highlight free boulders with sharp edges and sockets carved out in the rock platform. Boulders are composed of ruditic- to arenitic-size clastic carbonates. Their size ranges from 0.6 to 3.7 m, 0.55 to 2.4 m, and 0.2 to 1 m on the major (A), medium (B), and minor (C) axes, respectively. The highest value of mass estimation is 12.5 t. Almost all of boulders and sockets are characterized by a tabular or bladed shape. The comparisons between a) the fractures spacing and the length of A- and B-axes, and b) the frequency peaks of C-axis with the recurrent thickness of beds measured along the coastal zone demonstrate the litho-structural control in the size and shape of joint-bounded boulders. These comparisons, together with the similarity between the shapes of the boulders and those of the sockets as well as between the lithology of boulders and the areas surrounding the sockets, suggest that blocks originate by detachment from the platform edge. Thus, the most common pre-transport setting is the joint-bounded scenario. Hydrodynamic equations estimate that the storm wave heights necessary to initiate the transport of blocks diverge from 2 m to 8 m for joint-bounded boulders and from few tens of centimeters up to 11 m for submerged boulders. The comparison between the wave heights at the breaking point of the coastal zones with the results of hydrodynamic equations shows that waves approaching the coastline are able to transport all surveyed boulders. Our data suggest that boulders have been transported by several storm events, even in very recent times.
46 CFR 154.528 - Piping joints: Flange type.
Code of Federal Regulations, 2010 CFR
2010-10-01
... and Process Piping Systems § 154.528 Piping joints: Flange type. (a) A flange must be one of the following types: (1) Welding neck. (2) Slip-on. (3) Socket weld. (b) If the piping is designed for a... less; or (3) Welding neck. (c) If the piping is designed for a temperature lower than −55 °C (−67 °F...
Martin, Caroline; Bideau, Benoit; Bideau, Nicolas; Nicolas, Guillaume; Delamarche, Paul; Kulpa, Richard
2014-11-01
Energy flow has been hypothesized to be one of the most critical biomechanical concepts related to tennis performance and overuse injuries. However, the relationships among energy flow during the tennis serve, ball velocity, and overuse injuries have not been assessed. To investigate the relationships among the quality and magnitude of energy flow, the ball velocity, and the peaks of upper limb joint kinetics and to compare the energy flow during the serve between injured and noninjured tennis players. Case-control study; Level of evidence, 3. The serves of expert tennis players were recorded with an optoelectronic motion capture system. The forces and torques of the upper limb joints were calculated from the motion captures by use of inverse dynamics. The amount of mechanical energy generated, absorbed, and transferred was determined by use of a joint power analysis. Then the players were followed during 2 seasons to identify upper limb overuse injuries with a questionnaire. Finally, players were classified into 2 groups according to the questionnaire results: injured or noninjured. Ball velocity increased and upper limb joint kinetics decreased with the quality of energy flow from the trunk to the hand + racket segment. Injured players showed a lower quality of energy flow through the upper limb kinetic chain, a lower ball velocity, and higher rates of energy absorbed by the shoulder and elbow compared with noninjured players. The findings of this study imply that improper energy flow during the tennis serve can decrease ball velocity, increase upper limb joint kinetics, and thus increase overuse injuries of the upper limb joints. © 2014 The Author(s).
Hydrostatic self-aligning axial/torsional mechanism
O'Connor, Daniel G.; Gerth, Howard L.
1990-01-01
The present invention is directed to a self-aligning axial/torsional loading mechanism for testing the strength of brittle materials which are sensitive to bending moments. Disposed inside said self-aligning loading mechanism is a frictionless hydrostatic ball joint with a flexure ring to accommodate torsional loads through said ball joint.
Jia, Xiaohong; Zhang, Ming; Li, Xiaobing; Lee, Winson C C
2005-07-01
To predict the interface pressure between residual limb and prosthetic socket for trans-tibial amputees during walking. A quasi-dynamic finite element model was built based on the actual geometry of residual limb, internal bones and socket liner. To simulate the friction/slip boundary conditions between the skin and liner, automated surface-to-surface contact was used. Besides variable external loads and material inertia, the coupling between the large rigid displacement of knee joint and small elastic deformation of residual limb and prosthetic components were also considered. Interface pressure distribution was found to have the same profile during walking. The high pressures fall over popliteal depression, middle patella tendon, lateral tibia and medial tibia regions. Interface pressure predicted by static or quasi-dynamic analysis had the similar double-peaked waveform shape in stance phase. The consideration of inertial effects and motion of knee joint cause 210% average variation of the area between the pressure curve and the horizontal line of pressure threshold between two cases, even though there is only a small change in the peak pressure. The findings in this paper show that the coupling dynamic effects of inertial loads and knee flexion must be considered to study interface pressure between residual limb and prosthetic socket during walking.
Hierarchy of stability factors in reverse shoulder arthroplasty.
Gutiérrez, Sergio; Keller, Tony S; Levy, Jonathan C; Lee, William E; Luo, Zong-Ping
2008-03-01
Reverse shoulder arthroplasty is being used more frequently to treat irreparable rotator cuff tears in the presence of glenohumeral arthritis and instability. To date, however, design features and functions of reverse shoulder arthroplasty, which may be associated with subluxation and dislocation of these implants, have been poorly understood. We asked: (1) what is the hierarchy of importance of joint compressive force, prosthetic socket depth, and glenosphere size in relation to stability, and (2) is this hierarchy defined by underlying and theoretically predictable joint contact characteristics? We examined the intrinsic stability in terms of the force required to dislocate the humerosocket from the glenosphere of eight commercially available reverse shoulder arthroplasty devices. The hierarchy of factors was led by compressive force followed by socket depth; glenosphere size played a much lesser role in stability of the reverse shoulder arthroplasty device. Similar results were predicted by a mathematical model, suggesting the stability was determined primarily by compressive forces generated by muscles.
A Force-Velocity Relationship and Coordination Patterns in Overarm Throwing
van den Tillaar, Roland; Ettema, Gertjan
2004-01-01
A force-velocity relationship in overarm throwing was determined using ball weights varying from 0.2 to 0.8 kg. Seven experienced handball players were filmed at 240 frames per second. Velocity of joints of the upper extremity and ball together with the force on the ball were derived from the data. A statistically significant negative relationship between force and maximal ball velocity, as well as between ball weight and maximal ball velocity was observed. Also, with increase of ball weight the total throwing movement time increased. No significant change in relative timing of the different joints was demonstrated, suggesting that the subjects did not change their “global ”coordination pattern (kinematics) within the tested range of ball weights. A simple model revealed that 67% of ball velocity at ball release was explained by the summation of effects from the velocity of elbow extension and internal rotation of the shoulder. With regard to the upper extremity the internal rotation of the shoulder and elbow extension are two important contributors to the total ball velocity at release. Key Points An inverse relationship between load and velocity and a linear force-velocity exists in overarm throwing with ball weights varying from 0.2 to 0.8 kg. Qualitatively, no changes in coordination pattern (relative timing) occur with increasing ball weight within the tested range of ball weights. The absolute throwing movement time increased with ball weight. Quantitatively, with regard to the upper extremity, the internal rotation of the shoulder and elbow extension are two important contributors to the total ball velocity at release. PMID:24624005
Yang, Ying-yang; DU, Sheng-nan; Lv, Zong-kai
2015-08-01
To compare the results of high-speed handpiece and minimally invasive extraction in impacted mandibular third molar extraction. From May 2011 to May 2014, 83 patients undergoing impacted mandibular third molar extraction were enrolled into the study and randomly divided into 2 groups: 42 patients in group A (experimental group) and 41 patients in group B (control group). Group B underwent extraction with traditional method and group A underwent high-speed handpiece and minimally invasive extraction of the impacted mandibular third molar. The occurrences of the root fracture, gingival laceration, tooth mobility, lingual bone plate fracture, jaw fracture and dislocation of temporomandibular joint during operation and lower lip numbness, dry socket, facial swelling and limitation of mouth opening after operation were observed and compared between 2 groups. The operation time, integrity of extraction sockets, VAS pain score and satisfaction from patients were collected and compared. SPSS 19.0 software package was used for statistical analysis. The occurrences of root fracture, gingival laceration, tooth mobility, lingual bone plate fracture, jaw fracture, and dislocation of temporomandibular joint during operation in group A significantly decreased compared with group B (P<0.05). The occurrences of lower lip numbness, dry socket, facial swelling and limitation of mouth opening after operation in group A significantly decreased compared with group B (P<0.05). The operation time, integrity of extraction sockets, VAS pain scores and satisfaction scores in group A improved significantly compared with group B (P<0.05). High-speed handpiece and minimally invasive extraction should be widely used in impacted mandibular third molar extraction, due to the advantages of simple operation, high efficiency, minimal trauma, and few perioperative complications.
Global Positioning System Antenna Fixed Height Tripod Adapter
NASA Technical Reports Server (NTRS)
Dinardo, Steven J.; Smith, Mark A.
1997-01-01
An improved Global Positioning em antenna adaptor allows fixed antenna height measurements by removably attaching an adaptor plate to a conventional surveyor's tripod. Antenna height is controlled by an antenna boom which is a fixed length rod. The antenna is attached to one end of the boom. The opposite end of the boom tapers to a point sized to fit into a depression at the center of survey markers. The boom passes through the hollow center of a universal ball joint which is mounted at the center of the adaptor plate so that the point of the rod can be fixed in the marker's central depression. The mountains of the ball joint allow the joint to be moved horizontally in any direction relative to the tripod. When the ball joint is moved horizontally, the angle between the boom and the vertical changes because the boom's position is fixed at its lower end. A spirit level attached to the rod allows an operator to determine when the boom is plumb. The position of the ball joint is adjusted horizontally until the boom is plumb. At that time the antenna is positioned exactly over the center of the monument and the elevation of the antenna is precisely set by the length of the boom.
Load transfer mechanics between trans-tibial prosthetic socket and residual limb--dynamic effects.
Jia, Xiaohong; Zhang, Ming; Lee, Winson C C
2004-09-01
The effects of inertial loads on the interface stresses between trans-tibial residual limb and prosthetic socket were investigated. The motion of the limb and prosthesis was monitored using a Vicon motion analysis system and the ground reaction force was measured by a force platform. Equivalent loads at the knee joint during walking were calculated in two cases with and without consideration of the material inertia. A 3D nonlinear finite element (FE) model based on the actual geometry of residual limb, internal bones and socket liner was developed to study the mechanical interaction between socket and residual limb during walking. To simulate the friction/slip boundary conditions between the skin and liner, automated surface-to-surface contact was used. The prediction results indicated that interface pressure and shear stress had the similar double-peaked waveform shape in stance phase. The average difference in interface stresses between the two cases with and without consideration of inertial forces was 8.4% in stance phase and 20.1% in swing phase. The maximum difference during stance phase is up to 19%. This suggests that it is preferable to consider the material inertia effect in a fully dynamic FE model.
NASA Astrophysics Data System (ADS)
Qi, Dewei; Liu, Yingming; Shyy, Wei; Aono, Hikaru
2010-09-01
The lattice Boltzmann flexible particle method (LBFPM) is used to simulate fluid-structure interaction and motion of a flexible wing in a three-dimensional space. In the method, a beam with rectangular cross section has been discretized into a chain of rigid segments. The segments are connected through ball and socket joints at their ends and may be bent and twisted. Deformation of flexible structure is treated with a linear elasticity model through bending and twisting. It is demonstrated that the flexible particle method (FPM) can approximate the nonlinear Euler-Bernoulli beam equation without resorting to a nonlinear elasticity model. Simulations of plunge and pitch of flexible wing at Reynolds number Re=136 are conducted in hovering condition by using the LBFPM. It is found that both lift and drag forces increase first, then decrease dramatically as the bending rigidity in spanwise direction decreases and that the lift and drag forces are sensitive to rigidity in a certain range. It is shown that the downwash flows induced by wing tip and trailing vortices in wake area are larger for a flexible wing than for a rigid wing, lead to a smaller effective angle of attack, and result in a larger lift force.
NASA Astrophysics Data System (ADS)
Gu, Jian; Lei, YongPing; Lin, Jian; Fu, HanGuang; Wu, Zhongwei
2017-02-01
The reliability of Sn-3.0Ag-0.5Cu (SAC 305) solder joint under a broad level of drop impacts was studied. The failure performance of solder joint, failure probability and failure position were analyzed under two shock test conditions, i.e., 1000 g for 1 ms and 300 g for 2 ms. The stress distribution on the solder joint was calculated by ABAQUS. The results revealed that the dominant reason was the tension due to the difference in stiffness between the print circuit board and ball grid array, and the maximum tension of 121.1 MPa and 31.1 MPa, respectively, under both 1000 g or 300 g drop impact, was focused on the corner of the solder joint which was located in the outmost corner of the solder ball row. The failure modes were summarized into the following four modes: initiation and propagation through the (1) intermetallic compound layer, (2) Ni layer, (3) Cu pad, or (4) Sn-matrix. The outmost corner of the solder ball row had a high failure probability under both 1000 g and 300 g drop impact. The number of failures of solder ball under the 300 g drop impact was higher than that under the 1000 g drop impact. The characteristic drop values for failure were 41 and 15,199, respectively, following the statistics.
Luxation of Eye ball following trauma: Novel simple treatment
Osman, Essam A.; Al-Akeely, Adel
2014-01-01
Luxation of the eye globe is a rare occasion but it carries a risk of threat to permanent vision loss especially when associated with very high intraocular pressure. Appropriate intervention should be undertaken instantly. Predisposing factors include; eyes as in shallow orbital sockets, floppy eyelid syndrome, and exophthalmos. Prompt reduction results in restoration of full anatomical and visual recovery in otherwise healthy eyes. We report a case of globe luxation following trauma by door handle in a 65-year-old female, who recovered completely after reposition of the globe using Desmarres Lid Retractors. PMID:25116777
Shoulder and hip joint for hard space suits
NASA Technical Reports Server (NTRS)
Vykukal, H. C.
1986-01-01
Shoulder and hip joints for hard space suits are disclosed which are comprised of three serially connected truncated spherical sections, the ends of which converge. Ball bearings between the sections permit relative rotation. The proximal end of the first section is connected to the torso covering by a ball bearing and the distal end of the outermost section is connected to the elbow or thigh covering by a ball bearing. The sections are equi-angular and this alleviates lockup, the condition where the distal end of the joint leaves the plane in which the user is attempting to flex. The axes of rotation of the bearings and the bearing mid planes are arranged to intersect in a particular manner that provides the joint with a minimum envelope. In one embodiment, the races of the bearing between the innermost section and the second section is partially within the inner race of the bearing between the torso and the innermost spherical section further to reduce bulk.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...
Jang, Andrew T.; Lin, Jeremy D.; Seo, Youngho; Etchin, Sergey; Merkle, Arno; Fahey, Kevin; Ho, Sunita P.
2014-01-01
This study demonstrates a novel biomechanics testing protocol. The advantage of this protocol includes the use of an in situ loading device coupled to a high resolution X-ray microscope, thus enabling visualization of internal structural elements under simulated physiological loads and wet conditions. Experimental specimens will include intact bone-periodontal ligament (PDL)-tooth fibrous joints. Results will illustrate three important features of the protocol as they can be applied to organ level biomechanics: 1) reactionary force vs. displacement: tooth displacement within the alveolar socket and its reactionary response to loading, 2) three-dimensional (3D) spatial configuration and morphometrics: geometric relationship of the tooth with the alveolar socket, and 3) changes in readouts 1 and 2 due to a change in loading axis, i.e. from concentric to eccentric loads. Efficacy of the proposed protocol will be evaluated by coupling mechanical testing readouts to 3D morphometrics and overall biomechanics of the joint. In addition, this technique will emphasize on the need to equilibrate experimental conditions, specifically reactionary loads prior to acquiring tomograms of fibrous joints. It should be noted that the proposed protocol is limited to testing specimens under ex vivo conditions, and that use of contrast agents to visualize soft tissue mechanical response could lead to erroneous conclusions about tissue and organ-level biomechanics. PMID:24638035
Effects of Design Variants in Lower-Limb Prostheses on Gait Synergy
Pitkin, Mark R.
2016-01-01
A lower-limb prosthesis is the mechanical device with which an amputee’s residual limb interacts with the walking surface. The pressure and shear forces that affect the residuum due to prosthesis use are the sources of pain, residual-limb skin problems and gait deviations. Direct approaches to reducing these problems include improving fit, alignment technique and socket design as well as increasing cushioning with socket liners. A summary of typical malalignments and their consequences is presented. The malalignments are considered sources of excessive moments applied to the residuum, which simplifies the analysis of a patient’s gait. A better design of prosthetic joints could improve prosthetic gait. This article addresses the key mechanical parameter of prosthetic joints, namely the dependence “moment of resistance/angle of deflection.” A mathematical model has been developed that links stresses on the residuum in transtibial amputees with the moment of resistance in the prosthetic ankle at the critical gait phases. Analysis of the model yields a substantial decrease in stresses on the residuum during the most demanding, load-bearing phase of stance if the moment of resistance in the ankle is similar to that seen in the biological ankle joint. Gait study shows use of the experimental rolling-joint prosthetic foot more closely simulates normal gait synergy than the SACH foot. PMID:27087763
STS-57 inflight maintenance (IFM) tool tray at Boeing FEPF bench review
NASA Technical Reports Server (NTRS)
1993-01-01
STS-57 inflight maintenance (IFM) tool tray is displayed on a table top during the bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. The tool tray will be located on Endeavour's, Orbiter Vehicle (OV) 105's, middeck in forward locker MF57K and includes modified forceps, L-shaped hex wrenches, jeweler screwdrivers, adjustable wrench, bone saw, combination wrenches, override devices, switch guards, tape measure, torque driver, short screwdriver, long screwdriver, phillips screwdrivers, ratchet wrench, needlenose pliers, torque tips, adapter, universal joint, deepwell sockets, sockets, driver handle, seat adjustment tool, extensions, torque wrench, allen head drivers, hacksaw, and blades. Photo taken by NASA JSC contract photographer Benny Benavides.
Lo, Kuo-Cheng; Hsieh, Yung-Chun
2016-06-01
This study compared the kinetic roles of the upper extremities in racket impact force generation between the open stance (OS) and square stance (SS) for tennis players with different skill levels in two-handed backhand strokes. Twelve male tennis players were divided into an advanced group (AG) (L3-L2 skill level) and intermediate group (IG) (L7-L6 skill level), and their data were used in a three-dimensional kinetic analysis. Their motions were captured using 21 reflective markers attached to anatomic landmarks for two-handed backhand stroke motion data collection. During the acceleration phase, significant differences were not observed between both stances, but they were observed between the groups with different skill levels for the force of the upper extremities (p = 0.027). The joint forces were significantly lower in the AG than in the IG. Players performing the SS had significantly larger pronation and supination of the wrist joint moment than those in the OS (p = 0.032) during the acceleration phase, irrespective of the playing level. Higher internal rotation moment after impact was observed at each joint, particularly among young intermediate tennis players, regardless of their stance. The AG demonstrated a higher joint force and moment at every joint compared with the IG at impact. Moreover, the AG demonstrated superior stroke efficiency and effectively reduced joint moment after impact and sports injury. Key pointsAdvanced players, regardless of open stance or square stance, have larger joint force and moment at each joint before ball impact resulting in better stroke efficiency and reduced chance of injury.Intermediate players, regardless of stance, have higher internal rotation moment at each joint instead of larger joint force as compared to advanced players before ball impact. The higher internal rotation moment will induce higher joint impact force which makes the player injury-prone.Young intermediate tennis players may want to avoid excessive follow-through movement after ball impact to prevent injury in their early career.
ERIC Educational Resources Information Center
Jernigan, S. R.; Fahmy, Y.; Buckner, G. D.
2009-01-01
This paper details a successful and inexpensive implementation of a remote laboratory into a distance control systems course using readily available hardware and software. The physical experiment consists of a beach ball and a dc blower; the control objective is to make the height of the aerodynamically levitated beach ball track a reference…
Hutson, Joel David; Hutson, Kelda Nadine
2014-07-01
A recent study hypothesized that avian-like wrist folding in quadrupedal dinosaurs could have aided their distinctive style of locomotion with semi-pronated and therefore medially facing palms. However, soft tissues that automatically guide avian wrist folding rarely fossilize, and automatic wrist folding of unknown function in extant crocodilians has not been used to test this hypothesis. Therefore, an investigation of the relative contributions of soft tissues to wrist range of motion (ROM) in the extant phylogenetic bracket of dinosaurs, and the quadrupedal function of crocodilian wrist folding, could inform these questions. Here, we repeatedly measured wrist ROM in degrees through fully fleshed, skinned, minus muscles/tendons, minus ligaments, and skeletonized stages in the American alligator Alligator mississippiensis and the ostrich Struthio camelus. The effects of dissection treatment and observer were statistically significant for alligator wrist folding and ostrich wrist flexion, but not ostrich wrist folding. Final skeletonized wrist folding ROM was higher than (ostrich) or equivalent to (alligator) initial fully fleshed ROM, while final ROM was lower than initial ROM for ostrich wrist flexion. These findings suggest that, unlike the hinge/ball and socket-type elbow and shoulder joints in these archosaurs, ROM within gliding/planar diarthrotic joints is more restricted to the extent of articular surfaces. The alligator data indicate that the crocodilian wrist mechanism functions to automatically lock their semi-pronated palms into a rigid column, which supports the hypothesis that this palmar orientation necessitated soft tissue stiffening mechanisms in certain dinosaurs, although ROM-restricted articulations argue against the presence of an extensive automatic mechanism. Anat Rec, 297:1228-1249, 2014. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.
Acting Administrator Lightfoot Visits Ball Aerospace
2017-04-06
Michael Dean, senior project engineer for the Joint Polar Satellite System (JPSS) program at Ball Aerospace, right, speaks with acting NASA Deputy Administrator Lesa Roe, second from left, and acting NASA Administrator Robert Lightfoot, center, about the 20ft. by 24 ft. vertical thermal vacuum chamber, Thursday, April 6, 2017 during a visit to Ball Aerospace in Boulder, Colo. Photo Credit: (NASA/Joel Kowsky)
Biomechanical Characteristics and Determinants of Instep Soccer Kick
Kellis, Eleftherios; Katis, Athanasios
2007-01-01
Good kicking technique is an important aspect of a soccer player. Therefore, understanding the biomechanics of soccer kicking is particularly important for guiding and monitoring the training process. The purpose of this review was to examine latest research findings on biomechanics of soccer kick performance and identify weaknesses of present research which deserve further attention in the future. Being a multiarticular movement, soccer kick is characterised by a proximal-to-distal motion of the lower limb segments of the kicking leg. Angular velocity is maximized first by the thigh, then by the shank and finally by the foot. This is accomplished by segmental and joint movements in multiple planes. During backswing, the thigh decelerates mainly due to a motion-dependent moment from the shank and, to a lesser extent, by activation of hip muscles. In turn, forward acceleration of the shank is accomplished through knee extensor moment as well as a motion-dependent moment from the thigh. The final speed, path and spin of the ball largely depend on the quality of foot-ball contact. Powerful kicks are achieved through a high foot velocity and coefficient of restitution. Preliminary data indicate that accurate kicks are achieved through slower kicking motion and ball speed values. Key pointsSoccer kick is achieved through segmental and joint rotations in multiple planes and via the proximal-to-distal sequence of segmental angular velocities until ball impact. The quality of ball - foot impact and the mechanical behavior of the foot are also important determinants of the final speed, path and spin of the ball.Ball speed values during the maximum instep kick range from 18 to 35 msec-1 depending on various factors, such as skill level, age, approach angle and limb dominance.The main bulk of biomechanics research examined the biomechanics of powerful kicks, mostly under laboratory conditions. A powerful kick is characterized by the achievement of maximal ball speed. However, maximal ball speed does not guarantee a successful kick: in each case, the ball must reach the target. As already explained, when the player is instructed to hit the ball accurately, joint and segment velocities are lower as opposed to a fast and powerful kick performance. It is therefore apparent that future research should focus on biomechanics of fast but accurate kicking. PMID:24149324
Grunert, R; Schleifenbaum, S; Möbius, R; Sommer, G; Zajonz, D; Hammer, N; Prietzel, T
2017-02-01
Background: In total hip arthroplasty (THA), femoral head diameter has not been regarded as a key parameter which should be restored when reconstructing joint biomechanics and geometry. Apart from the controversial discussion on the advantages and disadvantages of using larger diameter heads, their higher cost is another important reason that they have only been used to a limited extent. The goal of this study was to analyse the price structure of prosthetic heads in comparison to other components used in THA. A large group of patients with hip endoprostheses were evaluated with respect to the implanted socket diameter and thus the theoretically attainable head diameter. Materials and Methods: The relative prices of various THA components (cups, inserts, stems and ball heads) distributed by two leading German manufacturers were determined and analysed. Special attention was paid to different sizes and varieties in a series of components. A large patient population treated with THA was evaluated with respect to the implanted cup diameter and therefore the theoretically attainable head diameter. Results: The pricing analysis of the THA components of two manufacturers showed identical prices for cups, inserts and stems in a series. In contrast to this, the prices for prosthetic heads with a diameter of 36-44 mm were 11-50 % higher than for 28 mm heads. Identical prices for larger heads were the exception. The distribution of the head diameter in 2719 THA cases showed significant differences between the actually implanted and the theoretically attainable heads. Conclusion: There are proven advantages in using larger diameter ball heads in THA and the remaining problems can be solved. It is therefore desirable to correct the current pricing practice of charging higher prices for larger components. Instead, identical prices should be charged for all head diameters in a series, as is currently established practice for all other THA components. Thus when reconstructing biomechanics and joint geometry in THA, it should be possible to recover not only leg length, femoral offset and antetorsion of the femoral neck, but also to approximately restore the diameter of the femoral head and thereby optimise the functional outcome. Georg Thieme Verlag KG Stuttgart · New York.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...
Code of Federal Regulations, 2014 CFR
2014-01-01
... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...
Code of Federal Regulations, 2014 CFR
2014-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.693 Joints. Control... in cable control systems. For ball or roller bearings, the approved ratings may not be exceeded...
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.693 Joints. Control... in cable control systems. For ball or roller bearings, the approved ratings may not be exceeded...
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.693 Joints. Control... in cable control systems. For ball or roller bearings, the approved ratings may not be exceeded...
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.693 Joints. Control... in cable control systems. For ball or roller bearings, the approved ratings may not be exceeded...
49 CFR 572.75 - Lumbar spine, abdomen, and pelvis assembly and test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... specified in Figure 42. (2) Adjust the dummy by— (i) Tightening the femur ballflange screws at each hip socket joint to 50 inch-pounds torque; (ii) Attaching the pelvis to the seating surface by a bolt D/605... drawing Figure 42. (iv) Tightening the mountings so that the pelvis-lumbar joining surface is horizontal...
49 CFR 572.75 - Lumbar spine, abdomen, and pelvis assembly and test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... specified in Figure 42. (2) Adjust the dummy by— (i) Tightening the femur ballflange screws at each hip socket joint to 50 inch-pounds torque; (ii) Attaching the pelvis to the seating surface by a bolt D/605... drawing Figure 42. (iv) Tightening the mountings so that the pelvis-lumbar joining surface is horizontal...
49 CFR 572.75 - Lumbar spine, abdomen, and pelvis assembly and test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... specified in Figure 42. (2) Adjust the dummy by— (i) Tightening the femur ballflange screws at each hip socket joint to 50 inch-pounds torque; (ii) Attaching the pelvis to the seating surface by a bolt D/605... drawing Figure 42. (iv) Tightening the mountings so that the pelvis-lumbar joining surface is horizontal...
49 CFR 572.75 - Lumbar spine, abdomen, and pelvis assembly and test procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... specified in Figure 42. (2) Adjust the dummy by— (i) Tightening the femur ballflange screws at each hip socket joint to 50 inch-pounds torque; (ii) Attaching the pelvis to the seating surface by a bolt D/605... drawing Figure 42. (iv) Tightening the mountings so that the pelvis-lumbar joining surface is horizontal...
49 CFR 572.75 - Lumbar spine, abdomen, and pelvis assembly and test procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... specified in Figure 42. (2) Adjust the dummy by— (i) Tightening the femur ballflange screws at each hip socket joint to 50 inch-pounds torque; (ii) Attaching the pelvis to the seating surface by a bolt D/605... drawing Figure 42. (iv) Tightening the mountings so that the pelvis-lumbar joining surface is horizontal...
NASA Astrophysics Data System (ADS)
Negrea, Adina; Busuioceanu, Ioana Iuliana
2018-02-01
Present paper estimates the mechanics of the impact of a ball and a hand-arm, during the sports training using a classical model for the hand-arm system, avoiding the contribution of the coefficient of restitution. The results of this investigation are focused on the equations needed to find out theimpact reactions in elbow and shoulder joints, for different anthropometric data. Also, the computing of the position of mass centers and the moments of inertia for each constitutive part of hand-arm system is made.
Application of the Blobo bluetooth ball in wrist rehabilitation training
Hsieh, Wei-Min; Hwang, Yuh-Shyan; Chen, Shih-Ching; Tan, Sun-Yen; Chen, Chih-Chen; Chen, Yu-Luen
2016-01-01
[Purpose] The introduction of emerging technologies such as the wireless Blobo bluetooth ball with multimedia features can enhance wrist physical therapy training, making it more fun and enhancing its effects. [Methods] Wrist injuries caused by fatigue at work, improper exercise, and other conditions are very common. Therefore, the reconstruction of wrist joint function is an important issue. The efficacy of a newly developed integrated wrist joint rehabilitation game using a Blobo bluetooth ball with C# software installed was tested in wrist rehabilitation (Flexion, Extension, Ulnar Deviation, Radial Deviation). [Results] Eight subjects with normal wrist function participated in a test of the system’s stability and repeatability. After performing the Blobo bluetooth ball wrist physical therapy training, eight patients with wrist dysfunction experienced approximately 10° improvements in range of motion (ROM) of flexion extension, and ulnar deviation and about 6° ROM improvement in radial deviation. The subjects showed progress in important indicators of wrist function. [Conclusion] This study used the Blobo bluetooth ball in wrist physical therapy training and the preliminary results were encouraging. In the future, more diverse wrist or limb rehabilitation games should be developed to meet the needs of physical therapy training. PMID:26957723
Application of the Blobo bluetooth ball in wrist rehabilitation training.
Hsieh, Wei-Min; Hwang, Yuh-Shyan; Chen, Shih-Ching; Tan, Sun-Yen; Chen, Chih-Chen; Chen, Yu-Luen
2016-01-01
[Purpose] The introduction of emerging technologies such as the wireless Blobo bluetooth ball with multimedia features can enhance wrist physical therapy training, making it more fun and enhancing its effects. [Methods] Wrist injuries caused by fatigue at work, improper exercise, and other conditions are very common. Therefore, the reconstruction of wrist joint function is an important issue. The efficacy of a newly developed integrated wrist joint rehabilitation game using a Blobo bluetooth ball with C# software installed was tested in wrist rehabilitation (Flexion, Extension, Ulnar Deviation, Radial Deviation). [Results] Eight subjects with normal wrist function participated in a test of the system's stability and repeatability. After performing the Blobo bluetooth ball wrist physical therapy training, eight patients with wrist dysfunction experienced approximately 10° improvements in range of motion (ROM) of flexion extension, and ulnar deviation and about 6° ROM improvement in radial deviation. The subjects showed progress in important indicators of wrist function. [Conclusion] This study used the Blobo bluetooth ball in wrist physical therapy training and the preliminary results were encouraging. In the future, more diverse wrist or limb rehabilitation games should be developed to meet the needs of physical therapy training.
49 CFR 570.61 - Suspension system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... or cracked, other than superficial surface cracks. Ball joints and kingpins shall not be bent or... bushings shall not be cracked, extruded out from or missing from suspension joints. Radius rods shall not...
49 CFR 570.61 - Suspension system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... or cracked, other than superficial surface cracks. Ball joints and kingpins shall not be bent or... bushings shall not be cracked, extruded out from or missing from suspension joints. Radius rods shall not...
[Increasing the safety of ceramic femoral heads for hip prostheses].
Willmann, G; Pfaff, H G; Richter, H G
1995-12-01
Since 1974 Biolox ceramic femoral ball heads have been used successfully for artificial modular hip joints. The revision rate due to ball head fracture is lower than 0.02%. This is an extremely low value. In this article it is shown how the safety of a ceramic ball head can be improved using the procedures of HIPing, engraving by laser technique, and 100% proof testing. By applying these means the materials properties density, grain size, grain size distribution, and the strength of the ball head, i.e. the fracture load can be improved significantly.
Biomechanical Analysis of Weighted-Ball Exercises for Baseball Pitchers.
Fleisig, Glenn S; Diffendaffer, Alek Z; Aune, Kyle T; Ivey, Brett; Laughlin, Walter A
Weighted-ball throwing programs are commonly used in training baseball pitchers to increase ball velocity. The purpose of this study was to compare kinematics and kinetics among weighted-ball exercises with values from standard pitching (ie, pitching standard 5-oz baseballs from a mound). Ball and arm velocities would be greater with lighter balls and joint kinetics would be greater with heavier balls. Controlled laboratory study. Twenty-five high school and collegiate baseball pitchers experienced with weighted-ball throwing were tested with an automated motion capture system. Each participant performed 3 trials of 10 different exercises: pitching 4-, 5-, 6-, and 7-oz baseballs from a mound; flat-ground crow hop throws with 4-, 5-, 6-, and 7-oz baseballs; and flat-ground hold exercises with 14- and 32-oz balls. Twenty-six biomechanical parameters were computed for each trial. Data among the 10 exercises were compared with repeated measures analysis of variance and post hoc paired t tests against the standard pitching data. Ball velocity increased as ball mass decreased. There were no differences in arm and trunk velocities between throwing a standard baseball and an underweight baseball (4 oz), while arm and trunk velocities steadily decreased as ball weight increased from 5 to 32 oz. Compared with values pitching from a mound, velocities of the pelvis, shoulder, and ball were increased for flat-ground throws. In general, as ball mass increased arm torques and forces decreased; the exception was elbow flexion torque, which was significantly greater for the flat-ground holds. There were significant differences in body positions when pitching on the mound, flat-ground throws, and holds. While ball velocity was greatest throwing underweight baseballs, results from the study did not support the rest of the hypothesis. Kinematics and kinetics were similar between underweight and standard baseballs, while overweight balls correlated with decreased arm forces, torques, and velocities. Increased ball velocity and joint velocities were produced with crow hop throws, likely because of running forward while throwing. As pitching slightly underweight and overweight baseballs produces variations in kinematics without increased arm kinetics, these exercises seem reasonable for training pitchers. As flat-ground throwing produces increased shoulder internal rotation velocity and elbow varus torque, these exercises may be beneficial but may also be stressful and risky. Flat-ground holds with heavy balls should not be viewed as enhancing pitching biomechanics, but rather as hybrid exercises between throwing and resistance training.
NASA Astrophysics Data System (ADS)
Huang, J. Q.; Zhou, M. B.; Zhang, X. P.
2017-03-01
In this work, the melting characteristics and interfacial reactions of Sn-ball/Sn-3.0Ag-0.5Cu-paste/Cu (Sn/SAC305-paste/Cu) structure joints were studied using differential scanning calorimetry, in order to gain a deeper and broader understanding of the interfacial behavior and metallurgical combination among the substrate (under-bump metallization), solder ball and solder paste in a board-level ball grid array (BGA) assembly process, which is often seen as a mixed assembly using solder balls and solder pastes. Results show that at the SAC305 melting temperature of 217°C, neither the SAC305-paste nor the Sn-ball coalesce, while an interfacial reaction occurs between the SAC305-paste and Cu. A slight increase in reflow temperature (from 217°C to 218°C) results in the coalescence of the SAC305-paste with the Sn-ball. The Sn-ball exhibits premelting behavior at reflow temperatures below its melting temperature, and the premelting direction is from the bottom to the top of the Sn-ball. Remarkably, at 227°C, which is nearly 5°C lower than the melting point of pure Sn, the Sn-ball melts completely, resulting from two eutectic reactions, i.e., the reaction between Sn and Cu and that between Sn and Ag. Furthermore, a large amount of bulk Cu6Sn5 phase forms in the solder due to the quick dissolution of Cu substrate when the reflow temperature is increased to 245°C. In addition, the growth of the interfacial Cu6Sn5 layer at the SAC305-paste/Cu interface is controlled mainly by grain boundary diffusion, while the growth of the interfacial Cu3Sn layer is controlled mainly by bulk diffusion.
NASA Astrophysics Data System (ADS)
You, Taehoon; Kim, Yunsung; Kim, Jina; Lee, Jaehong; Jung, Byungwook; Moon, Jungtak; Choe, Heeman
2009-03-01
Despite being expensive and time consuming, board-level drop testing has been widely used to assess the drop or impact resistance of the solder joints in handheld microelectronic devices, such as cellphones and personal digital assistants (PDAs). In this study, a new test method, which is much simpler and quicker, is proposed. The method involves evaluating the elastic strain energy and relating it to the impact resistance of the solder joint by considering the Young’s modulus of the bulk solder and the fracture stress of the solder joint during a ball pull test at high strain rates. The results show that solder joints can be ranked in order of descending elastic strain energy as follows: Sn-37Pb, Sn-1Ag-0.5Cu, Sn-3Ag-0.5Cu, and Sn-4Ag-0.5Cu. This order is consistent with the actual drop performances of the samples.
Nakamura, Shinichiro; Sharma, Adrija; Kobayashi, Masahiko; Ito, Hiromu; Nakamura, Kenji; Zingde, Sumesh M; Nakamura, Takashi; Komistek, Richard D
2014-01-01
Kneeling position can serve as an important posture, providing stability and balance from a standing position to sitting on the floor or vice-versa. The purpose of the current study was to determine the kinematics during kneeling activities after subjects were implanted with a tri-condylar total knee arthroplasty. Kinematics was evaluated in 54 knees using fluoroscopy and a three-dimensional model fitting approach. The average knee flexion at before contact status, at complete contact and at maximum flexion was 98.1±9.0°, 107.2±6.7°, and 139.6±12.3°, respectively. On average, there was no gross anterior displacement from before contact status to complete contact. Only slight posterior rollback motion of both condyles from complete contact to maximum flexion was observed. Three of 39 (7.7%) knees experienced anterior movement of both condyles more than 2mm from before contact status to complete contact. Reverse rotation pattern from before contact status to complete contact and then normal rotation pattern from complete contact to maximum flexion were observed. Condylar lift-off greater than 1.0 mm was observed in 45 knees (83.3%). The presence of the ball-and-socket joint articulation provides sufficient antero-posterior stability in these designs to enable the patients to kneel safely without the incidence of any dislocation. This study suggests a safe implant design for kneeling. © 2013.
Landing gear energy absorption system
NASA Technical Reports Server (NTRS)
Hansen, Christopher P. (Inventor)
1994-01-01
A landing pad system is described for absorbing horizontal and vertical impact forces upon engagement with a landing surface where circumferentially arranged landing struts respectively have a clevis which receives a slidable rod member and where the upper portion of a slidable rod member is coupled to the clevis by friction washers which are force fit onto the rod member to provide for controlled constant force energy absorption when the rod member moves relative to the clevis. The lower end of the friction rod is pivotally attached by a ball and socket to a support plate where the support plate is arranged to slide in a transverse direction relative to a housing which contains an energy absorption material for absorbing energy in a transverse direction.
Titanium clip ball joint: a partial ossicular reconstruction prosthesis.
Beutner, Dirk; Luers, Jan Christoffer; Bornitz, Matthias; Zahnert, Thomas; Huttenbrink, Karl-Bernd
2011-06-01
To describe a new titanium clip prosthesis for partial ossicular reconstruction with a micro ball joint in the headplate for compensation of tympanic membrane displacements. Laboratory experiments followed by 18 consecutive patients. A micro ball joint was implemented into a headplate of titanium middle ear prosthesis. First, the new prosthesis was tested in the laboratory in temporal bone experiments. Second, the new prosthesis was clinically installed in 18 patients. Results of laser Doppler vibrometry and force measurements in the laboratory experiments, analysis of a questionnaire, and preoperative and postoperative pure tone audiometry. The frictional resistance in the joint was measured to be 12 mN that should allow for adequate mobility under physiologic conditions. The effective sound transmission of the prosthesis was demonstrated by laser Doppler vibrometry. Intraoperatively, the installation of the prosthesis was always straightforward with headplate prosthesis shaft angles between 60 and 90 degrees. Postoperatively, pure tone audiometry revealed satisfying hearing results with a remaining average air-bone gap of 18.2 dB over the frequencies 500, 1,000, 2,000, and 3,000 Hz. No signs of prosthesis dislocation were discovered within the follow-up period of approximately 6 months. The experimental data show that the new modified prosthesis headplate fulfills the requirements necessary for sound transmission. The joint allows the plate to follow movements of the tympanic membrane. This characteristic in conjunction with the proven clip design ensure for optimal prosthesis placement and effectiveness.
Recrystallization Behavior in Mixed Solder Joints of BGA Components during Thermal Shock
NASA Astrophysics Data System (ADS)
Tan, Shihai; Han, Jing; Guo, Fu
2018-03-01
Sn-37Pb and Sn-3.0Ag-0.5Cu solder pastes printed onto a board were attached to ball grid array (BGA) samples using Sn-3.0Ag-0.5Cu solder balls. Before thermal shock, the initial grain orientations on the cross-section were obtained by scanning electron microscopy equipped with an electron backscattered diffraction system. Three mixed solder joints (two from the corner and another from the middle of the BGA component) and three lead-free solder joints (at the same positions) were selected to investigate the recrystallization behavior under thermal shock (TS) cycling conditions. All of the mixed and lead-free solder joints were initially single crystal. The results showed that recrystallization occurred in both the mixed and lead-free solder joints after 200 TS. For the mixed solder joints, more recrystallization was observed and the location of samples had a significant influence on their recrystallization behavior, while location was not as important for the lead-free samples after 200 TS in this study. Both the mixed and lead-free solder joints at the corner of BGA components showed the poorest reliability. According to misorientation distribution maps and subgrain rotation behaviors, the reliability of mixed solder joints was much poorer than that of lead-free solder joints.
King, Mark; Hau, Agnes; Blenkinsop, Glen
2017-07-01
Recreational tennis players tend to have higher incidence of tennis elbow, and this has been hypothesised to be related to one-handed backhand technique and off-centre ball impacts on the racket face. This study aimed to investigate for a range of participants the effect of off-longitudinal axis and off-lateral axis ball-racket impact locations on racket and forearm joint angle changes immediately following impact in one-handed tennis backhand groundstrokes. Three-dimensional racket and wrist angular kinematic data were recorded for 14 university tennis players each performing 30 "flat" one-handed backhand groundstrokes. Off-longitudinal axis ball-racket impact locations explained over 70% of the variation in racket rotation about the longitudinal axis and wrist flexion/extension angles during the 30 ms immediately following impact. Off-lateral axis ball-racket impact locations had a less clear cut influence on racket and forearm rotations. Specifically off-longitudinal impacts below the longitudinal axis forced the wrist into flexion for all participants with there being between 11° and 32° of forced wrist flexion for an off-longitudinal axis impact that was 1 ball diameter away from the midline. This study has confirmed that off-longitudinal impacts below the longitudinal axis contribute to forced wrist flexion and eccentric stretch of the wrist extensors and there can be large differences in the amount of forced wrist flexion from individual to individual and between strokes with different impact locations.
Beil, Jonas; Marquardt, Charlotte; Asfour, Tamim
2017-07-01
Kinematic compatibility is of paramount importance in wearable robotic and exoskeleton design. Misalignments between exoskeletons and anatomical joints of the human body result in interaction forces which make wearing the exoskeleton uncomfortable and even dangerous for the human. In this paper we present a kinematically compatible design of an exoskeleton hip to reduce kinematic incompatibilities, so called macro- and micro-misalignments, between the human's and exoskeleton's joint axes, which are caused by inter-subject variability and articulation. The resulting design consists of five revolute, three prismatic and one ball joint. Design parameters such as range of motion and joint velocities are calculated based on the analysis of human motion data acquired by motion capture systems. We show that the resulting design is capable of self-aligning to the human hip joint in all three anatomical planes during operation and can be adapted along the dorsoventral and mediolateral axis prior to operation. Calculation of the forward kinematics and FEM-simulation considering kinematic and musculoskeletal constraints proved sufficient mobility and stiffness of the system regarding the range of motion, angular velocity and torque admissibility needed to provide 50 % assistance for an 80 kg person.
Quantitative assessment of joint position sense recovery in subacute stroke patients: a pilot study.
Kattenstroth, Jan-Christoph; Kalisch, Tobias; Kowalewski, Rebecca; Tegenthoff, Martin; Dinse, Hubert R
2013-11-01
To assess joint position sense performance in subacute stroke patients using a novel quantitative assessment. Proof-of-principle pilot study with a group of subacute stroke patients. Assessment at baseline and after 2 weeks of intervention. Additional data for a healthy age-matched control group. Ten subacute stroke patients (aged 65.41 years (standard deviation 2.5), 4 females, 2.3 weeks (standard deviation 0.2)) post-stroke receiving in-patient standard rehabilitation and repetitive electrical stimulation of the affected hand. Joint position sense was assessed based on the ability of correctly perceiving the opening angles of the finger joints. Patients had to report size differences of polystyrene balls of various sizes, whilst the balls were enclosed simultaneously by the affected and the non-affected hands. A total of 21 pairwise size comparisons was used to quantify joint position performance. After 2 weeks of therapeutic intervention a significant improvement in joint position sense performance was observed; however, the performance level was still below that of a healthy control group. The results indicate high feasibility and sensitivity of the joint position test in subacute stroke patients. Testing allowed quantification of both the deficit and the rehabilitation outcome.
Abdelhamid, Alaa; Omran, Mostafa; Bakhshalian, Neema; Tarnow, Dennis; Zadeh, Homayoun H
2016-06-01
The aims of this study were (i) to evaluate the efficacy of ridge preservation and repair procedures involving the application of SocketKAP(™) and SocketKAGE(™) devices following tooth removal and (ii) to evaluate alveolar bone volumetric changes at 6 months post-extraction in intact sockets or those with facial wall dehiscence defects using 3-dimensional pre- and postoperative CBCT data. Thirty-six patients required 61 teeth extracted. Five cohorts were established: Group A: Intact Socket Negative Control Group B: Intact Socket + SocketKAP(™) Group C: Intact Socket Filled with Anorganic Bovine Bone Mineral (ABBM) + SocketKAP(™) Group D: Facial Dehiscence Socket Negative Control Group E: Facial Dehiscence Socket Filled with ABBM + SocketKAP(™) + SocketKAGE(™) . Preoperative CBCT scans were obtained followed by digital subtraction of the test teeth. At 6 months post-extraction, another CBCT scan was obtained. The pre- and postoperative scans were then superimposed, allowing highly accurate quantitative determination of the 3D volumetric alveolar bone volume changes from baseline through 6 months. Significant volumetric bone loss occurred in all sockets, localized mainly in the 0-3 mm zone apical to the ridge crest. For intact sockets, SocketKAP(™) + ABBM treatment led to a statistically significant greater percentage of remaining mineralized tissue volume when compared to negative control group. A significant difference favoring SocketKAP(™) + SocketKAGE(™) + ABBM treatment was observed for sockets with facial dehiscence defects compared to the negative control group. SocketKAP(™) , with ABBM, appears effective in limiting post-extraction volumetric bone loss in intact sockets, while SocketKAP(™) + SocketKAGE + ABBM appears effective in limiting post-extraction bone loss in sockets with dehiscence defects. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Resnik, Linda; Patel, Tarpit; Cooney, Shane G; Crisco, Joseph J; Fantini, Christopher
2016-01-01
This case study compares the impact of two prosthetic socket designs, a "traditional" transhumeral (TH) socket design and a Compression Released Stabilized (CRS) socket. A CRS socket was compared to the existing socket of two persons with transhumeral amputation. Comparisons included assessments of patient comfort and satisfaction with fit, as well as dynamic kinematic assessment using a novel high-speed, high-resolution, bi-plane video radiography system (XROMM, for X-ray Reconstruction of Moving Morphology). Subjects were more satisfied with the comfort of the traditional sockets, although they had positive impressions about aspects of the fit and style of the CRS socket, and thought that it provided better control. Dynamic kinematic assessment revealed that the CRS socket provided better control of the residual limb within the socket, and had less slippage as compared to a traditional TH socket design. The TH CRS socket provided better control of the residual limb within the socket, and had less slippage. However, participants were less satisfied with the comfort and overall utility of the CRS socket, and stated that additional fitting visits/modifications to the CRS socket were needed. It is possible that satisfaction with the CRS socket may have improved with prosthetic adjustment and more acclimation time. Implications for Rehabilitation A comfortable, good fitting prosthetic socket is the key factor in determining how long (or if) an upper limb amputee can tolerate wearing a prosthesis. This case series was a comparison of two socket designs, a 'traditional' socket design and a Compression Released Stabilized (CRS) socket design in persons with transhumeral amputation. The CRS socket provided better control of the residual limb within the socket, and had less slippage. However, its tightness made it more difficult to don. Both subjects were less satisfied with the comfort and overall utility of the CRS socket. However, satisfaction might have been improved with additional fitting visits and more acclimation time.
Abd Razak, Nasrul A; Abu Osman, Noor A; Ali, Sadeeq A; Gholizadeh, Hossein
2016-01-15
While considering how important the interface between the amputees with the prostheses socket, we have carried out research to compare the gradient pressure occur at the interface socket that may lead to the discomforting effects to the user using common ICRC polypropylene socket and air splint socket. Not Applicable SETTING: Not Applicable POPULATION: The subject was a 23 year old who suffered a traumatic defect on the right arm caused by higher electrical volt. F-Socket sensors have been used to measure dynamic socket interface pressure for the transradial amputee wearer during static and dynamic movements. The printed circuit with a thickness of 0.18 mm is equipped between the socket and the surface of the residual limb. Two F-Socket sensor is required to cover the entire socket surface attached to the residual limb. The average of 10 trials made on prosthetic user using both type of sockets for static and dynamic movements was recorded. The pressure gradient shows that the circumference of the socket interface for the ICRC polypropylene socket gives the most pressure distributions to the amputees compared to the pressure gradient for the air splint socket. The pressure gradient for ICRC socket increased consistently when the user makes movements while for the air splint socket remain constantly. The specific interface pressure occur at the socket interface help in determine the comfort and pain of the socket design and improve the correlation between the user and the prosthesis.
The Controllable Ball Joint Mechanism
NASA Astrophysics Data System (ADS)
Tung, Yung Cheng; Chieng, Wei-Hua; Ho, Shrwai
A controllable ball joint mechanism with three rotational degrees of freedom is proposed in this paper. The mechanism is composed of three bevel gears, one of which rotates with respect to a fixed frame and the others rotate with respect to individual floating frames. The output is the resultant motion of the differential motions by the motors that rotates the bevel gears at the fixed frame and the floating frames. The mechanism is capable of a large rotation, and the structure is potentially compact. The necessary inverse and forward kinematic analyses as well as the derivation of kinematic singularity are provided according to the kinematical equivalent structure described in this paper.
Analysis of the 5 iron golf swing when hitting for maximum distance.
Healy, Aoife; Moran, Kieran A; Dickson, Jane; Hurley, Cillian; Smeaton, Alan F; O'Connor, Noel E; Kelly, Philip; Haahr, Mads; Chockalingam, Nachiappan
2011-07-01
Most previous research on golf swing mechanics has focused on the driver club. The aim of this study was to identify the kinematic factors that contribute to greater hitting distance when using the 5 iron club. Three-dimensional marker coordinate data were collected (250 Hz) to calculate joint kinematics at eight key swing events, while a swing analyser measured club swing and ball launch characteristics. Thirty male participants were assigned to one of two groups, based on their ball launch speed (high: 52.9 ± 2.1 m · s(-1); low: 39.9 ± 5.2 m · s(-1)). Statistical analyses were used to identify variables that differed significantly between the two groups. Results showed significant differences were evident between the two groups for club face impact point and a number of joint angles and angular velocities, with greater shoulder flexion and less left shoulder internal rotation in the backswing, greater extension angular velocity in both shoulders at early downswing, greater left shoulder adduction angular velocity at ball contact, greater hip joint movement and X Factor angle during the downswing, and greater left elbow extension early in the downswing appearing to contribute to greater hitting distance with the 5 iron club.
Bańkosz, Ziemowit; Winiarski, Sławomir
2018-06-01
The aim of this study was to determine the correlations between angular velocities in individual joints and racket velocity for different topspin forehand and backhand strokes in table tennis. Ten elite female table tennis players participated, presenting different kinds of topspin forehands and backhands - after a no-spin ball (FH1, BH1), after a backspin ball (FH2, BH2) and "heavy" topspin (FH3, BH3). Range of motion was measured with the BTS Smart-E (BTS Bioengineering, Milan, Italy) motion analysis system with a specially developed marker placement protocol for the upper body parts and an acoustic sensor attached to the racket to identify ball-racket contact. In forehand strokes angular velocities of internal arm rotation and adduction in shoulder joint correlated with racket velocity. Racket velocity was correlated with angular velocities (hip extension on the playing side; hip flexion on the opposite side; ankle flexion) in the case of a topspin forehand performed with maximal force -"heavy" topspin (FH3). In backhand strokes the velocities of arm abduction and shoulder girdle rotation towards the playing side correlated with racket velocity. The angular velocity of internal arm rotation and adduction in shoulder joint may be important components of a coordinated stroke, whilst angular velocity can substantially affect the racket speed when one is changing the type of stroke.
NASA Technical Reports Server (NTRS)
Swikert, M. A.; Johnson, R. L.
1976-01-01
Experiments were conducted on a newly designed total hip joint simulator. The apparatus closely simulates the complex motions and loads of the human hip in normal walking. The wear and friction of presently used appliance configurations and materials were determined. A surface treatment of the metal femoral ball specimens was applied to influence wear. The results of the investigation indicate that wear can be reduced by mechanical treatment of metal femoral ball surfaces. A metallographic examination and surface roughness measurements were made.
Long-term results of uncemented alumina acetabular implants.
Boehler, M; Knahr, K; Plenk, H; Walter, A; Salzer, M; Schreiber, V
1994-01-01
We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on mental femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 microns per year in a stable implant and 68 microns in a loose implant. Survival analysis showed a revision rate of 12.4% at 136 months.
Correlation of Shoulder and Elbow Kinetics With Ball Velocity in Collegiate Baseball Pitchers.
Post, Eric G; Laudner, Kevin G; McLoda, Todd A; Wong, Regan; Meister, Keith
2015-06-01
Throwing a baseball is a dynamic and violent act that places large magnitudes of stress on the shoulder and elbow. Specific injuries at the elbow and glenohumeral joints have been linked to several kinetic variables throughout the throwing motion. However, very little research has directly examined the relationship between these kinetic variables and ball velocity. To examine the correlation of peak ball velocity with elbow-valgus torque, shoulder external-rotation torque, and shoulder-distraction force in a group of collegiate baseball pitchers. Cross-sectional study. Motion-analysis laboratory. Sixty-seven asymptomatic National Collegiate Athletic Association Division I baseball pitchers (age = 19.5 ± 1.2 years, height = 186.2 ± 5.7 cm, mass = 86.7 ± 7.0 kg; 48 right handed, 19 left handed). We measured peak ball velocity using a radar gun and shoulder and elbow kinetics of the throwing arm using 8 electronically synchronized, high-speed digital cameras. We placed 26 reflective markers on anatomical landmarks of each participant to track 3-dimensional coordinate data. The average data from the 3 highest-velocity fastballs thrown for strikes were used for data analysis. We calculated a Pearson correlation coefficient to determine the associations between ball velocity and peak elbow-valgus torque, shoulder-distraction force, and shoulder external-rotation torque (P < .05). A weak positive correlation was found between ball velocity and shoulder-distraction force (r = 0.257; 95% confidence interval [CI] = 0.02, 0.47; r(2) = 0.066; P = .018). However, no significant correlations were noted between ball velocity and elbow-valgus torque (r = 0.199; 95% CI = -0.043, 0.419; r(2) = 0.040; P = .053) or shoulder external-rotation torque (r = 0.097; 95% CI = -0.147, 0.329; r(2) = 0.009; P = .217). Although a weak positive correlation was present between ball velocity and shoulder-distraction force, no significant association was seen between ball velocity and elbow-valgus torque or shoulder external-rotation torque. Therefore, other factors, such as improper pitching mechanics, may contribute more to increases in joint kinetics than peak ball velocity.
Correlation of Shoulder and Elbow Kinetics With Ball Velocity in Collegiate Baseball Pitchers
Post, Eric G.; Laudner, Kevin G.; McLoda, Todd A.; Wong, Regan; Meister, Keith
2015-01-01
Context Throwing a baseball is a dynamic and violent act that places large magnitudes of stress on the shoulder and elbow. Specific injuries at the elbow and glenohumeral joints have been linked to several kinetic variables throughout the throwing motion. However, very little research has directly examined the relationship between these kinetic variables and ball velocity. Objective To examine the correlation of peak ball velocity with elbow-valgus torque, shoulder external-rotation torque, and shoulder-distraction force in a group of collegiate baseball pitchers. Design Cross-sectional study. Setting Motion-analysis laboratory. Patients or Other Participants Sixty-seven asymptomatic National Collegiate Athletic Association Division I baseball pitchers (age = 19.5 ± 1.2 years, height = 186.2 ± 5.7 cm, mass = 86.7 ± 7.0 kg; 48 right handed, 19 left handed). Main Outcome Measure(s) We measured peak ball velocity using a radar gun and shoulder and elbow kinetics of the throwing arm using 8 electronically synchronized, high-speed digital cameras. We placed 26 reflective markers on anatomical landmarks of each participant to track 3-dimensional coordinate data. The average data from the 3 highest-velocity fastballs thrown for strikes were used for data analysis. We calculated a Pearson correlation coefficient to determine the associations between ball velocity and peak elbow-valgus torque, shoulder-distraction force, and shoulder external-rotation torque (P < .05). Results A weak positive correlation was found between ball velocity and shoulder-distraction force (r = 0.257; 95% confidence interval [CI] = 0.02, 0.47; r2 = 0.066; P = .018). However, no significant correlations were noted between ball velocity and elbow-valgus torque (r = 0.199; 95% CI = −0.043, 0.419; r2 = 0.040; P = .053) or shoulder external-rotation torque (r = 0.097; 95% CI = −0.147, 0.329; r2 = 0.009; P = .217). Conclusions Although a weak positive correlation was present between ball velocity and shoulder-distraction force, no significant association was seen between ball velocity and elbow-valgus torque or shoulder external-rotation torque. Therefore, other factors, such as improper pitching mechanics, may contribute more to increases in joint kinetics than peak ball velocity. PMID:25756790
Nucleation rates of Sn in undercooled Sn-Ag-Cu flip-chip solder joints
NASA Astrophysics Data System (ADS)
Arfaei, B.; Benedict, M.; Cotts, E. J.
2013-11-01
The nucleation of Sn from the melt in commercial SnAgCu flip chip solder joints was monitored at a number of different temperatures. Nucleation rates were estimated from measurements of nucleation times for 440 solder balls after one reflow and were found to be well epitomized by the expression I = 2 × 109 exp[(-1.6 × 105)/(T × (ΔT)2)] m-3 s-1, as per classical nucleation theory. After an additional reflow, the nucleation rates of the same 440 samples were observed to increase to I = 2 × 109 exp[(-8.9 × 104)/(T × (ΔT)2)] m-3 s-1. Thus it was shown that the expressions of classical nucleation theory well characterize nucleation kinetics for this system. These changes in nucleation kinetics were correlated with continued dissolution of Al and Ni in to the SnAgCu melt. Such increases in nucleation rates meant increases in the average solidification temperatures of the solder balls after reflow. Variations in the Sn grain morphology of the solder joints were correlated with these changes in solidification temperature, with larger Sn grains (beach ball Sn grain morphology) observed at higher solidification temperatures.
Zadeh, Homayoun H; Abdelhamid, Alaa; Omran, Mostafa; Bakhshalian, Neema; Tarnow, Dennis
2016-06-01
The aims of this study were to evaluate (i) the efficacy of ridge preservation and repair involving SocketKAP(™) and SocketKAGE(™) devices following tooth removal; and (ii) ridge contour changes at 6 months post-extraction in intact sockets and sockets with dehiscence defects. Thirty-six patients required a total of 61 teeth to be extracted. Five cohorts were established with groups A-C involving intact sockets and groups D and E involving facial dehiscence: (A) Negative Control; (B) SocketKAP(™) alone; (C) Anorganic Bovine Bone Mineral (ABBM) + SocketKAP(™) ; (D) Negative Control; and (E) ABBM + SocketKAP(™) + SocketKAGE(™) . Preoperative CBCT and laser-scanned casts were obtained. Teeth segmented from preoperative CBCT were merged with study cast images to allow for digital removal of teeth from the casts. Volumetric measurements of ridge contour were performed. Images of preoperative and 6 months post-operative casts were superimposed to measure ridge contour changes. Post-extraction contour loss occurred in all sockets primarily in the crestal 3 mm but was also detected up to 6 mm from alveolar crest. For intact sockets, SocketKAP(™) or SocketKAP(™) + ABBM interventions led to greater percentages of remaining ridge contour when compared to controls. A significant difference favoring SocketKAP(™) + SocketKAGE(™) + ABBM treatment was observed for sockets with facial dehiscence when compared to controls. SocketKAP(™) , with or without ABBM, significantly limited post-extraction ridge contour loss in intact sockets. In the absence of a group treated with only the SocketKAGE(™) , it is not possible to determine its efficacy, although the combination of SocketKAGE(™) + SocketKAP(™) + ABBM was effective in limiting post-extraction ridge contour loss in sockets with dehiscence defects. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The Power of a Soccer Ball: A Traumatic Open Finger Dislocation-A Rare Case Presentation.
Dülgeroğlu, Turan Cihan; Metineren, Hasan; Aydın, Ekrem; Dülgeroğlu, Ayşegül
2015-01-01
Proximal interphalangeal joint dislocations are injuries observed frequently and caused by axial loading on the finger in the extension. In this paper we present a traumatic open finger dislocation due to a ball hitting a wrestler. It was successfully treated with reduction and the volar plate and collateral bond fixation were applied with absorbable sutures.
Effects of Socket Size on Metrics of Socket Fit in Trans-Tibial Prosthesis Users
Sanders, Joan E; Youngblood, Robert T; Hafner, Brian J; Cagle, John C; McLean, Jake B; Redd, Christian B; Dietrich, Colin R; Ciol, Marcia A; Allyn, Katheryn J
2017-01-01
The purpose of this research was to conduct a preliminary effort to identify quantitative metrics to distinguish a good socket from an oversized socket in people with trans-tibial amputation. Results could be used to inform clinical practices related to socket replacement. A cross-over study was conducted on community ambulators (K-level 3 or 4) with good residual limb sensation. Participants were each provided with two sockets, a duplicate of their as-prescribed socket and a modified socket that was enlarged or reduced by 1.8 mm (~6% of the socket volume) based on the fit quality of the as-prescribed socket. The two sockets were termed a larger socket and a smaller socket. Activity was monitored while participants wore each socket for 4wk. Participants’ gait; self-reported satisfaction, quality of fit, and performance; socket comfort; and morning-to-afternoon limb fluid volume changes were assessed. Visual analysis of plots and estimated effect sizes (measure as mean difference divided by standard deviation) showed largest effects for step time asymmetry, step width asymmetry, anterior and anterior-distal morning-to-afternoon fluid volume change, socket comfort scores, and self-reported measures of utility, satisfaction, and residual limb health. These variables may be viable metrics for early detection of deterioration in socket fit, and should be tested in a larger clinical study. PMID:28373013
Effects of socket size on metrics of socket fit in trans-tibial prosthesis users.
Sanders, Joan E; Youngblood, Robert T; Hafner, Brian J; Cagle, John C; McLean, Jake B; Redd, Christian B; Dietrich, Colin R; Ciol, Marcia A; Allyn, Katheryn J
2017-06-01
The purpose of this research was to conduct a preliminary effort to identify quantitative metrics to distinguish a good socket from an oversized socket in people with trans-tibial amputation. Results could be used to inform clinical practices related to socket replacement. A cross-over study was conducted on community ambulators (K-level 3 or 4) with good residual limb sensation. Participants were each provided with two sockets, a duplicate of their as-prescribed socket and a modified socket that was enlarged or reduced by 1.8mm (∼6% of the socket volume) based on the fit quality of the as-prescribed socket. The two sockets were termed a larger socket and a smaller socket. Activity was monitored while participants wore each socket for 4 weeks. Participants' gait; self-reported satisfaction, quality of fit, and performance; socket comfort; and morning-to-afternoon limb fluid volume changes were assessed. Visual analysis of plots and estimated effect sizes (measured as mean difference divided by standard deviation) showed largest effects for step time asymmetry, step width asymmetry, anterior and anterior-distal morning-to-afternoon fluid volume change, socket comfort score, and self-reported utility. These variables may be viable metrics for early detection of deterioration in socket fit, and should be tested in a larger clinical study. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Fatone, Stefania; Caldwell, Ryan
2017-06-01
Current transfemoral prosthetic sockets are problematic as they restrict function, lack comfort, and cause residual limb problems. Development of a subischial socket with lower proximal trim lines is an appealing way to address this problem and may contribute to improving quality of life of persons with transfemoral amputation. The purpose of this study was to illustrate the use of a new subischial socket in two subjects. Case series. Two unilateral transfemoral prosthesis users participated in preliminary socket evaluations comparing functional performance of the new subischial socket to ischial containment sockets. Testing included gait analysis, socket comfort score, and performance-based clinical outcome measures (Rapid-Sit-To-Stand, Four-Square-Step-Test, and Agility T-Test). For both subjects, comfort was better in the subischial socket, while gait and clinical outcomes were generally comparable between sockets. While these evaluations are promising regarding the ability to function in this new socket design, more definitive evaluation is needed. Clinical relevance Using gait analysis, socket comfort score and performance-based outcome measures, use of the Northwestern University Flexible Subischial Vaccum Socket was evaluated in two transfemoral prosthesis users. Socket comfort improved for both subjects with comparable function compared to ischial containment sockets.
Martin, C; Bideau, B; Ropars, M; Delamarche, P; Kulpa, R
2014-08-01
The aim of this work was to compare the joint kinetics and stroke production efficiency for the shoulder, elbow, and wrist during the serve between professionals and advanced tennis players and to discuss their potential relationship with given overuse injuries. Eleven professional and seven advanced tennis players were studied with an optoelectronic motion analysis system while performing serves. Normalized peak kinetic values of the shoulder, elbow, and wrist joints were calculated using inverse dynamics. To measure serve efficiency, all normalized peak kinetic values were divided by ball velocity. t-tests were used to determine significant differences between the resultant joint kinetics and efficiency values in both groups (advanced vs professional). Shoulder inferior force, shoulder anterior force, shoulder horizontal abduction torque, and elbow medial force were significantly higher in advanced players. Professional players were more efficient than advanced players, as they maximize ball velocity with lower joint kinetics. Since advanced players are subjected to higher joint kinetics, the results suggest that they appeared more susceptible to high risk of shoulder and elbow injuries than professionals, especially during the cocking and deceleration phases of the serve. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Hip joint kinetics in the table tennis topspin forehand: relationship to racket velocity.
Iino, Yoichi
2018-04-01
The purpose of this study was to determine hip joint kinetics during a table tennis topspin forehand, and to investigate the relationship between the relevant kinematic and kinetic variables and the racket horizontal and vertical velocities at ball impact. Eighteen male advanced table tennis players hit cross-court topspin forehands against backspin balls. The hip joint torque and force components around the pelvis coordinate system were determined using inverse dynamics. Furthermore, the work done on the pelvis by these components was also determined. The peak pelvis axial rotation velocity and the work done by the playing side hip pelvis axial rotation torque were positively related to the racket horizontal velocity at impact. The sum of the work done on the pelvis by the backward tilt torques and the upward joint forces was positively related to the racket vertical velocity at impact. The results suggest that the playing side hip pelvis axial rotation torque exertion is important for acquiring a high racket horizontal velocity at impact. The pelvis backward tilt torques and upward joint forces at both hip joints collectively contribute to the generation of the racket vertical velocity, and the mechanism for acquiring the vertical velocity may vary among players.
Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J
2014-07-01
To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.
Computer-socket manufacturing error: How much before it is clinically apparent?
Sanders, Joan E.; Severance, Michael R.; Allyn, Kathryn J.
2015-01-01
The purpose of this research was to pursue quality standards for computer-manufacturing of prosthetic sockets for people with transtibial limb loss. Thirty-three duplicates of study participants’ normally used sockets were fabricated using central fabrication facilities. Socket-manufacturing errors were compared with clinical assessments of socket fit. Of the 33 sockets tested, 23 were deemed clinically to need modification. All 13 sockets with mean radial error (MRE) greater than 0.25 mm were clinically unacceptable, and 11 of those were deemed in need of sizing reduction. Of the remaining 20 sockets, 5 sockets with interquartile range (IQR) greater than 0.40 mm were deemed globally or regionally oversized and in need of modification. Of the remaining 15 sockets, 5 sockets with closed contours of elevated surface normal angle error (SNAE) were deemed clinically to need shape modification at those closed contour locations. The remaining 10 sockets were deemed clinically acceptable and not in need modification. MRE, IQR, and SNAE may serve as effective metrics to characterize quality of computer-manufactured prosthetic sockets, helping facilitate the development of quality standards for the socket manufacturing industry. PMID:22773260
Design of a novel prosthetic socket: assessment of the thermal performance.
Webber, Christina M; Davis, Brian L
2015-05-01
Prosthetic liners and sockets insulate the residual limb, causing excessive sweating and concomitant skin maceration. When coupled with atypical loading conditions, further dermatologic problems can arise. This can significantly reduce the quality of life of an amputee patient. Improving the design of the prosthetic socket has been proposed as a means of reestablishing a normal thermal environment around the residual limb. In this study, a prosthetic socket was modified by incorporating a helical cooling channel within the socket wall using additive manufacturing techniques. Two sockets were modeled: a control socket, and a modified socket containing a 0.48 cm diameter cooling channel. Computer simulations and bench-top testing were used to assess the design's ability to create a greater temperature differential across the socket wall. A greater temperature drop across the socket wall suggested that the socket could provide cooling benefits to the residual limb by allowing for heat to be drawn away from the limb. The temperature difference across the socket wall was calculated for both sockets in each aspect of the study. Both socket type (p=0.002) and location on the socket (p=0.014) were statistically significant factors affecting the temperature difference between inner and outer socket walls. Compared with the control socket, the modified socket containing a helical cooling channel exhibited greater temperature differences across its wall of 11.1 °C and 6.4 °C in the computer simulations and bench-top testing, respectively. This finding suggested that socket modifications, such as the cooling channel presented, could provide a beneficial cooling effect to an amputee patient's residual limb. Copyright © 2015 Elsevier Ltd. All rights reserved.
Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek M; Colvin, James M
2011-01-01
Prosthetic sockets serve as the interface between people with amputations and their prostheses. Although most materials used to make prosthetic sockets have been used for many years, knowledge of these materials' properties is limited, especially after they are subjected to fabrication processes. This study evaluated tensile and impact properties of the current state-of-the-art materials used to fabricate prosthetic check sockets, copolymer sockets, and definitive laminated sockets. Thermolyn Rigid and Orfitrans Stiff check socket materials produced significantly lower tensile strength and impact resistance than polyethylene terephthalate glycol (PETG). Copolymer socket materials exhibited greater resistance to impact forces than the check socket materials but lower tensile strengths than PETG. The heated molding processes, for the check socket and copolymer materials, reduced both tensile strength and elongation at break. Definitive laminated sockets were sorted according to fabrication techniques. Nyglass material had significantly higher elongation, indicating a more ductile material than carbon-based laminations. Carbon sockets with pigmented resin had higher tensile strength and modulus at break than nonpigmented carbon sockets. Elongation at yield and elongation at break were similar for both types of carbon-based laminations. The material properties determined in this study provide a foundation for understanding and improving the quality of prosthetic sockets using current fabrication materials and a basis for evaluating future technologies.
Fatone, Stefania; Caldwell, Ryan
2017-01-01
Background: Current transfemoral prosthetic sockets are problematic as they restrict function, lack comfort, and cause residual limb problems. Development of a subischial socket with lower proximal trim lines is an appealing way to address this problem and may contribute to improving quality of life of persons with transfemoral amputation. Objectives: The purpose of this study was to illustrate the use of a new subischial socket in two subjects. Study design: Case series. Methods: Two unilateral transfemoral prosthesis users participated in preliminary socket evaluations comparing functional performance of the new subischial socket to ischial containment sockets. Testing included gait analysis, socket comfort score, and performance-based clinical outcome measures (Rapid-Sit-To-Stand, Four-Square-Step-Test, and Agility T-Test). Results: For both subjects, comfort was better in the subischial socket, while gait and clinical outcomes were generally comparable between sockets. Conclusion: While these evaluations are promising regarding the ability to function in this new socket design, more definitive evaluation is needed. Clinical relevance Using gait analysis, socket comfort score and performance-based outcome measures, use of the Northwestern University Flexible Subischial Vaccum Socket was evaluated in two transfemoral prosthesis users. Socket comfort improved for both subjects with comparable function compared to ischial containment sockets. PMID:28132589
A Probabilistic Approach to Predict Thermal Fatigue Life for Ball Grid Array Solder Joints
NASA Astrophysics Data System (ADS)
Wei, Helin; Wang, Kuisheng
2011-11-01
Numerous studies of the reliability of solder joints have been performed. Most life prediction models are limited to a deterministic approach. However, manufacturing induces uncertainty in the geometry parameters of solder joints, and the environmental temperature varies widely due to end-user diversity, creating uncertainties in the reliability of solder joints. In this study, a methodology for accounting for variation in the lifetime prediction for lead-free solder joints of ball grid array packages (PBGA) is demonstrated. The key aspects of the solder joint parameters and the cyclic temperature range related to reliability are involved. Probabilistic solutions of the inelastic strain range and thermal fatigue life based on the Engelmaier model are developed to determine the probability of solder joint failure. The results indicate that the standard deviation increases significantly when more random variations are involved. Using the probabilistic method, the influence of each variable on the thermal fatigue life is quantified. This information can be used to optimize product design and process validation acceptance criteria. The probabilistic approach creates the opportunity to identify the root causes of failed samples from product fatigue tests and field returns. The method can be applied to better understand how variation affects parameters of interest in an electronic package design with area array interconnections.
Dry Socket Etiology, Diagnosis, and Clinical Treatment Techniques.
Mamoun, John
2018-04-01
Dry socket, also termed fibrinolytic osteitis or alveolar osteitis, is a complication of tooth exodontia. A dry socket lesion is a post-extraction socket that exhibits exposed bone that is not covered by a blood clot or healing epithelium and exists inside or around the perimeter of the socket or alveolus for days after the extraction procedure. This article describes dry socket lesions; reviews the basic clinical techniques of treating different manifestations of dry socket lesions; and shows how microscope level loupe magnification of 6× to 8× or greater, combined with co-axial illumination or a dental operating microscope, facilitate more precise treatment of dry socket lesions. The author examines the scientific validity of the proposed causes of dry socket lesions (such as bacteria, inflammation, fibrinolysis, or traumatic extractions) and the scientific validity of different terminologies used to describe dry socket lesions. This article also presents an alternative model of what causes dry socket lesions, based on evidence from dental literature. Although the clinical techniques for treating dry socket lesions seem empirically correct, more evidence is required to determine the causes of dry socket lesions.
Dry Socket Etiology, Diagnosis, and Clinical Treatment Techniques
2018-01-01
Dry socket, also termed fibrinolytic osteitis or alveolar osteitis, is a complication of tooth exodontia. A dry socket lesion is a post-extraction socket that exhibits exposed bone that is not covered by a blood clot or healing epithelium and exists inside or around the perimeter of the socket or alveolus for days after the extraction procedure. This article describes dry socket lesions; reviews the basic clinical techniques of treating different manifestations of dry socket lesions; and shows how microscope level loupe magnification of 6× to 8× or greater, combined with co-axial illumination or a dental operating microscope, facilitate more precise treatment of dry socket lesions. The author examines the scientific validity of the proposed causes of dry socket lesions (such as bacteria, inflammation, fibrinolysis, or traumatic extractions) and the scientific validity of different terminologies used to describe dry socket lesions. This article also presents an alternative model of what causes dry socket lesions, based on evidence from dental literature. Although the clinical techniques for treating dry socket lesions seem empirically correct, more evidence is required to determine the causes of dry socket lesions. PMID:29732309
Functional Multijoint Position Reproduction Acuity in Overhead-Throwing Athletes
Tripp, Brady L; Uhl, Timothy L; Mattacola, Carl G; Srinivasan, Cidambi; Shapiro, Robert
2006-01-01
Context: Baseball players rely on the sensorimotor system to uphold the balance between upper extremity stability and mobility while maintaining athletic performance. However, few researchers have studied functional multijoint measures of sensorimotor acuity in overhead-throwing athletes. Objective: To compare sensorimotor acuity between 2 high-demand functional positions and among planes of motion within individual joints and to describe a novel method of measuring sensorimotor function. Design: Single-session, repeated-measures design. Setting: University musculoskeletal research laboratory. Patients or Other Participants: Twenty-one National Collegiate Athletic Association Division I baseball players (age = 20.8 ± 1.5 years, height = 181.3 ± 5.1 cm, mass = 87.8 ± 9.1 kg) with no history of upper extremity injury or central nervous system disorder. Main Outcome Measure(s): We measured active multijoint position reproduction acuity in multiple planes using an electromagnetic tracking device. Subjects reproduced 2 positions: arm cock and ball release. We calculated absolute and variable error for individual motions at the scapulothoracic, glenohumeral, elbow, and wrist joints and calculated overall joint acuity with 3-dimensional variable error. Results: Acuity was significantly better in the arm-cock position compared with ball release at the scapulothoracic and glenohumeral joints. We observed significant differences among planes of motion within the scapulothoracic and glenohumeral joints at ball release. Scapulothoracic internal rotation and glenohumeral horizontal abduction and rotation displayed less acuity than other motions. Conclusions: We established the reliability of a functional measure of upper extremity sensorimotor system acuity in baseball players. Using this technique, we observed differences in acuity between 2 test positions and among planes of motion within the glenohumeral and scapulothoracic joints. Clinicians may consider these differences when designing and implementing sensorimotor system training. Our error scores are similar in magnitude to those reported using single-joint and single-plane measures. However, 3-dimensional, multijoint measures allow practical, unconstrained test positions and offer additional insight into the upper extremity as a functional unit. PMID:16791298
An active locking mechanism for assembling 3D micro structures
NASA Astrophysics Data System (ADS)
Zhang, Ping; Mayyas, Mohammad; Lee, Woo Ho; Popa, Dan; Shiakolas, Panos; Stephanou, Harry; Chiao, J. C.
2007-01-01
Microassembly is an enabling technology to build 3D microsystems consisting of microparts made of different materials and processes. Multiple microparts can be connected together to construct complicated in-plane and out-of-plane microsystems by using compliant mechanical structures such as micro hinges and snap fasteners. This paper presents design, fabrication, and assembly of an active locking mechanism that provides mechanical and electrical interconnections between mating microparts. The active locking mechanism is composed of thermally actuated Chevron beams and sockets. Assembly by means of an active locking mechanism offers more flexibility in designing microgrippers as it reduces or minimizes mating force, which is one of the main reasons causing fractures in a microgripper during microassembly operation. Microgrippers, microparts, and active locking mechanisms were fabricated on a silicon substrate using the deep reactive ion etching (DRIE) processes with 100-um thick silicon on insulator (SOI) wafers. A precision robotic assembly platform with a dual microscope vision system was used to automate the manipulation and assembly processes of microparts. The assembly sequence includes (1) tether breaking and picking up of a micropart by using an electrothermally actuated microgripper, (2) opening of a socket area for zero-force insertion, (3) a series of translation and rotation of a mating micropart to align it onto the socket, (4) insertion of a micropart into the socket, and (5) deactivation and releasing of locking fingers. As a result, the micropart was held vertically to the substrate and locked by the compliance of Chevron beams. Microparts were successfully assembled using the active locking mechanism and the measured normal angle was 89.2°. This active locking mechanism provides mechanical and electrical interconnections, and it can potentially be used to implement a reconfigurable microrobot that requires complex assembly of multiple links and joints.
Kumar, Neelesh
2014-10-01
Finite element analysis has been universally employed for the stress and strain analysis in lower extremity prosthetics. The socket adapter was the principal subject of interest due to its importance in deciding the knee motion range. This article focused on the static and dynamic stress analysis of the designed hybrid adapter developed by the authors. A standard mechanical design validation approach using von Mises was followed. Four materials were considered for the analysis, namely, carbon fiber, oil-filled nylon, Al-6061, and mild steel. The paper analyses the static and dynamic stress on designed hybrid adapter which incorporates features of conventional male and female socket adapters. The finite element analysis was carried out for possible different angles of knee flexion simulating static and dynamic gait situation. Research was carried out on available design of socket adapter. Mechanical design of hybrid adapter was conceptualized and a CAD model was generated using Inventor modelling software. Static and dynamic stress analysis was carried out on different materials for optimization. The finite element analysis was carried out on the software Autodesk Inventor Professional Ver. 2011. The peak value of von Mises stress occurred in the neck region of the adapter and in the lower face region at rod eye-adapter junction in static and dynamic analyses, respectively. Oil-filled nylon was found to be the best material among the four with respect to strength, weight, and cost. Research investigations on newer materials for development of improved prosthesis will immensely benefit the amputees. The study analyze the static and dynamic stress on the knee joint adapter to provide better material used for hybrid design of adapter. © The International Society for Prosthetics and Orthotics 2013.
Statistical atlas based extrapolation of CT data
NASA Astrophysics Data System (ADS)
Chintalapani, Gouthami; Murphy, Ryan; Armiger, Robert S.; Lepisto, Jyri; Otake, Yoshito; Sugano, Nobuhiko; Taylor, Russell H.; Armand, Mehran
2010-02-01
We present a framework to estimate the missing anatomical details from a partial CT scan with the help of statistical shape models. The motivating application is periacetabular osteotomy (PAO), a technique for treating developmental hip dysplasia, an abnormal condition of the hip socket that, if untreated, may lead to osteoarthritis. The common goals of PAO are to reduce pain, joint subluxation and improve contact pressure distribution by increasing the coverage of the femoral head by the hip socket. While current diagnosis and planning is based on radiological measurements, because of significant structural variations in dysplastic hips, a computer-assisted geometrical and biomechanical planning based on CT data is desirable to help the surgeon achieve optimal joint realignments. Most of the patients undergoing PAO are young females, hence it is usually desirable to minimize the radiation dose by scanning only the joint portion of the hip anatomy. These partial scans, however, do not provide enough information for biomechanical analysis due to missing iliac region. A statistical shape model of full pelvis anatomy is constructed from a database of CT scans. The partial volume is first aligned with the statistical atlas using an iterative affine registration, followed by a deformable registration step and the missing information is inferred from the atlas. The atlas inferences are further enhanced by the use of X-ray images of the patient, which are very common in an osteotomy procedure. The proposed method is validated with a leave-one-out analysis method. Osteotomy cuts are simulated and the effect of atlas predicted models on the actual procedure is evaluated.
Bańkosz, Ziemowit; Winiarski, Sławomir
2018-01-01
The aim of this study was to determine the correlations between angular velocities in individual joints and racket velocity for different topspin forehand and backhand strokes in table tennis. Ten elite female table tennis players participated, presenting different kinds of topspin forehands and backhands – after a no-spin ball (FH1, BH1), after a backspin ball (FH2, BH2) and “heavy” topspin (FH3, BH3). Range of motion was measured with the BTS Smart-E (BTS Bioengineering, Milan, Italy) motion analysis system with a specially developed marker placement protocol for the upper body parts and an acoustic sensor attached to the racket to identify ball-racket contact. In forehand strokes angular velocities of internal arm rotation and adduction in shoulder joint correlated with racket velocity. Racket velocity was correlated with angular velocities (hip extension on the playing side; hip flexion on the opposite side; ankle flexion) in the case of a topspin forehand performed with maximal force –”heavy” topspin (FH3). In backhand strokes the velocities of arm abduction and shoulder girdle rotation towards the playing side correlated with racket velocity. The angular velocity of internal arm rotation and adduction in shoulder joint may be important components of a coordinated stroke, whilst angular velocity can substantially affect the racket speed when one is changing the type of stroke. Key points The aim of this study was to calculate correlations between racket velocity and the angular velocities of individual joints and for variants of topspin forehand and backhand strokes in table tennis. A novel model was used to estimate range of motion (specially developed placement protocol for upper body markers and identification of a ball-racket contact using an acoustic sensor attached to the racket). In forehand strokes angular velocities of internal arm rotation and adduction in shoulder joint were correlated with racket velocity. Correlations between racket velocity and the angular velocities of playing- and non-playing-side hip extension and ankle flexion were found in topspin forehands. In topspin backhands abduction of the arm had the greatest impact on the racket speed. The results can be used directly to improve training of table tennis techniques, especially topspin strokes. PMID:29769835
Wenke, Jamie L.; McDonald, W. Hayes; Schey, Kevin L.
2016-01-01
Purpose To quantify protein changes in the morphologically distinct remodeling zone (RZ) and adjacent regions of the human lens outer cortex using spatially directed quantitative proteomics. Methods Lightly fixed human lens sections were deparaffinized and membranes labeled with fluorescent wheat germ agglutinin (WGA-TRITC). Morphology directed laser capture microdissection (LCM) was used to isolate tissue from four distinct regions of human lens outer cortex: differentiating zone (DF), RZ, transition zone (TZ), and inner cortex (IC). Liquid chromatography-tandem mass spectrometry (LC-MS/MS) of the plasma membrane fraction from three lenses (21-, 22-, and 27-year) revealed changes in major cytoskeletal proteins including vimentin, filensin, and phakinin. Peptides from proteins of interest were quantified using multiple reaction monitoring (MRM) mass spectrometry and isotopically-labeled internal peptide standards. Results Results revealed an intermediate filament switch from vimentin to beaded filament proteins filensin and phakinin that occurred at the RZ. Several other cytoskeletal proteins showed significant changes between regions, while most crystallins remained unchanged. Targeted proteomics provided accurate, absolute quantification of these proteins and confirmed vimentin, periplakin, and periaxin decrease from the DF to the IC, while filensin, phakinin, and brain acid soluble protein 1 (BASP1) increase significantly at the RZ. Conclusions Mass spectrometry-compatible fixation and morphology directed laser capture enabled proteomic analysis of narrow regions in the human lens outer cortex. Results reveal dramatic cytoskeletal protein changes associated with the RZ, suggesting that one role of these proteins is in membrane deformation and/or the establishment of ball and socket joints in the human RZ. PMID:27537260
Lens fiber organization in four avian species: a scanning electron microscopic study.
Willekens, B; Vrensen, G
1985-01-01
The three-dimensional organization of the eye lenses of the chicken, the canary, the song-thrush and the kestrel was studied using light and scanning electron microscopy. The lenses of birds are characterized by the presence of two distinct compartments: the annular pad and the main lens body, separated by a cavum lenticuli. The annular pad fibers had a hexagonal circumference all contained a round nucleus and except for the canary were smooth-surfaced and lacking anchoring devices. In the canary, however, the annular pad fibers were studded with edge protrusions and ball-and-socket junctions. The semicircular main lens body fibers of all four species were studded with ball-and-socket junctions and edge protrusions. In contrast with mammals these anchoring devices were present throughout the lens up to the embryonal nucleus. Superficially the main lens body fibers were extremely flat. Additionally membrane elevations and depressions and globular elements were found on these central fibers in three species, the kestrel being the exception. At the transition between annular pad and main lens body the fibers turned their course and the nuclei became oval and disappeared in the deeper aspect of the main lens body. The cavum lenticuli was filled with globules tied off from the annular pad fibers. It seems attractive to assume that the presence of a separated annular pad, a cavum lenticuli filled with globular elements, the extreme flatness of the superficial central fibers and the studding of these central fibers with anchoring devices up to the embryonal nucleus are morphological expressions of the mouldability of the bird's eye lenses and consequently would explain their efficient accommodative mechanism including formation of a lenticonus. The presence of nuclei in the annular pad fibers and their typical change at the transitional zone between annular pad and main lens body are suggestive for a two-phased differentiation in bird's lens fibers: differentiation of the germinative epithelial cells to annular pad fibers which migrate to the main lens body after which they differentiate further to main lens body fibers.
Fatone, Stefania; Caldwell, Ryan
2017-06-01
Current transfemoral prosthetic sockets restrict function, lack comfort, and cause residual limb problems. Lower proximal trim lines are an appealing way to address this problem. Development of a more comfortable and possibly functional subischial socket may contribute to improving quality of life of persons with transfemoral amputation. The purpose of this study was to (1) describe the design and fabrication of a new subischial socket and (2) describe efforts to teach this technique. Development project. Socket development involved defining the following: subject and liner selection, residual limb evaluation, casting, positive mold rectification, check socket fitting, definitive socket fabrication, and troubleshooting of socket fit. Three hands-on workshops to teach the socket were piloted and attended by 30 certified prosthetists and their patient models. Patient models responded positively to the comfort, range of motion, and stability of the new socket while prosthetists described the technique as "straight forward, reproducible." To our knowledge, this is the first attempt to create a teachable subischial socket, and while it appears promising, more definitive evaluation is needed. Clinical relevance We developed the Northwestern University Flexible Subischial Vacuum (NU-FlexSIV) Socket as a more comfortable alternative to current transfemoral sockets and demonstrated that it could be taught successfully to prosthetists.
Ibrahiem, Mohamed F. K.; Abdelaziz, Sahar T. A.
2016-01-01
Purpose. To evaluate a new surgical technique using fascia lata to deepen the shallow inferior conjunctival fornix in contracted socket and anophthalmic socket syndrome. Methods. A prospective controlled study in which 24 sockets of 24 patients who were unable to wear and retain their ocular prosthesis due to shallow inferior fornix were enrolled and categorized into anophthalmic socket syndromes (9 patients) and contracted sockets (15 patients). Another 24 patients who underwent evisceration or enucleation with healthy sockets and can wear and retain their prosthesis comfortably were chosen as a control group. Deepening of the fornix was performed using fascia lata strips under general anesthesia. Central depth of the inferior fornix was measured preoperatively and postoperatively. Results. A statistically significant improvement of the postoperative central inferior fornix depth was reported which was marked in anophthalmic subgroup. 100% of anophthalmic sockets and 93.3% of contracted sockets achieved satisfactory results during the follow-up period with no postoperative lower eyelid malposition or obvious skin scar. Conclusion. Fascia lata technique is a new alternative and effective procedure to deepen the shallow inferior fornix that can be used in moderate to severe contracted sockets or anophthalmic socket syndrome with minimal lower eyelid or socket complications. PMID:27313868
Ibrahiem, Mohamed F K; Abdelaziz, Sahar T A
2016-01-01
Purpose. To evaluate a new surgical technique using fascia lata to deepen the shallow inferior conjunctival fornix in contracted socket and anophthalmic socket syndrome. Methods. A prospective controlled study in which 24 sockets of 24 patients who were unable to wear and retain their ocular prosthesis due to shallow inferior fornix were enrolled and categorized into anophthalmic socket syndromes (9 patients) and contracted sockets (15 patients). Another 24 patients who underwent evisceration or enucleation with healthy sockets and can wear and retain their prosthesis comfortably were chosen as a control group. Deepening of the fornix was performed using fascia lata strips under general anesthesia. Central depth of the inferior fornix was measured preoperatively and postoperatively. Results. A statistically significant improvement of the postoperative central inferior fornix depth was reported which was marked in anophthalmic subgroup. 100% of anophthalmic sockets and 93.3% of contracted sockets achieved satisfactory results during the follow-up period with no postoperative lower eyelid malposition or obvious skin scar. Conclusion. Fascia lata technique is a new alternative and effective procedure to deepen the shallow inferior fornix that can be used in moderate to severe contracted sockets or anophthalmic socket syndrome with minimal lower eyelid or socket complications.
Kobayashi, Yasuto; Ae, Michiyoshi; Miyazaki, Akiyo; Fujii, Norihisa; Iiboshi, Akira; Nakatani, Hideki
2016-09-01
The purpose of this study was to investigate joint kinetics of the throwing arms and role of trunk motion in skilled elementary school boys during an overarm distance throw. Throwing motions of 42 boys from second, fourth, and sixth grade were videotaped with three high-speed cameras operating at 300 fps. Seven skilled boys from each grade were selected on the basis of throwing distance for three-dimensional kinetic analysis. Joint forces, torques, and torque powers of the throwing arm joints were calculated from reconstructed three-dimensional coordinate data smoothed at cut-off frequencies of 10.5-15 Hz and by the inverse dynamics method. Throwing distance and ball velocity significantly increased with school grade. The angular velocity of elbow extension before ball release increased with school grade, although no significant increase between the grades was observed in peak extension torque of elbow joint. The joint torque power of shoulder internal/external rotation tended to increase with school grade. When teaching the overarm throw, elementary school teachers should observe large backward twisting of trunk during the striding phase and should keep in mind that young children, such as second graders (age 8 years), will be unable to effectively utilise shoulder external/internal rotation during the throwing phase.
Electrical grounding prong socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leong, R.
1989-09-12
This paper describes a socket for a grounding prong used in a three prong electrical plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. 11 figs.
Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure.
Razak, Nasrul Anuar Abd; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq
2014-08-01
The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. The subject's dynamic pressure on the socket that's applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics.
Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure
2014-01-01
Background The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee’s satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. Methods The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. Results The subject’s dynamic pressure on the socket that’s applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. Conclusion The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics. PMID:25085005
Design and Use of a 3D Prosthetic Leg in a Red-lored Amazon Parrot ( Amazona autumnalis).
Galicia, Cecilia; Hernandez Urraca, Vanessa; Del Castillo, Luis; Mvz, Jaime Samour
2018-06-01
A three-dimensional (3D) prosthesis was designed and built for a red-lored Amazon parrot ( Amazona autumnalis) with a pre-existing amputation of the distal left leg at the tibiotarsal-tarsometatarsal joint and injuries to the right leg caused by cage companion aggression. The prosthesis consisted of a straight main imprint, with a round element at both ends to provide stability, and a bridge connecting this to a socket without a bottom where the stump could be accommodated and held securely with self-adhesive bandaging. Over a 4-month period, 3 different 3D prosthetic models were made and evaluated. The first model was fitted, but the parrot would only use the tip of the main imprint to stand and walk. The second model was designed with a semicircular imprint with only 1 round element at the cranial end, a different bridge to accommodate the change to the main imprint, and the same socket. With these changes, the parrot was able to place the imprint of the prosthesis on the floor to stand and move freely around its enclosure. To accommodate morphologic changes on the stump, a third model was created consisting of the same imprint and bridge, but the socket was cut vertically all the way on one side to allow distention on its diameter and provide a long-lasting fit to the stump over time.
Failure Simulation Testing of the Z-1 Spacesuit Titanium Bearing Assemblies
NASA Technical Reports Server (NTRS)
de Baca, Richard C.; Juarez, Alfredo; Peralta, Stephen; Tylka, Jonathan; Rhodes, Richard
2016-01-01
The Z-2 is a candidate for NASA's next generation spacesuit, designed for a range of possible missions with enhanced mobility for spacewalks both on planetary surfaces and in microgravity. Increased mobility was accomplished through innovations in shoulder and hip joints, using a number of new bearings to allow spacesuit wearers to dip, walk, and bend with ease; all important tasks for a planetary explorer collecting samples or traveling over rough terrain. The Advanced Spacesuit Development Team of NASA Johnson Space Center requested that the NASA White Sands Test Facility (WSTF) perform a series failure simulation tests on three titanium bearing assemblies, an elemental part of the joint construction used in new spacesuit designs. This testing simulated two undetected failures within the bearings and as a result the objective of this test program was to evaluate whether a failed or failing bearing could result in ignition of the titanium race material due to friction. The first failure was an inner seal leak sufficient to pressurize the race with +99 percent oxygen. The second failure was an improperly installed or mismatched ball port that created a protrusion in the ball bearing race, partially obstructing the nominal rolling path of each ball bearing. When the spacesuit bearings are assembled, bearing balls are loaded into the assembly via a ball port. The ball port is specific and unique to each bearing assembly (matched pair). The simulated mismatched ball port is a significant source of friction, which would be caused by an assembly error. To evaluate this risk, the bearings were cycled in a simulated worst-case scenario environment, with operational loads, and potential flaw conditions. During test the amount of actuation torque required and heat generated through continuous operation were measured and the bearings were observed for sparks or burning events. This paper provides detailed descriptions of the test hardware, methodology, and results.
SDAI: a key piece of software to manage the new wideband backend at Robledo
NASA Astrophysics Data System (ADS)
Rizzo, J. R.; Gutiérrez Bustos, M.; Kuiper, T. B. H.; Cernicharo, J.; Sotuela, I.; Pedreira, A.
2012-09-01
A joint collaborative project was recently developed to provide the Madrid Deep Space Communications Complex with a state-of-the-art wideband backend. This new backend provides from 100MHz to 6 GHz of instantaneous bandwidth, and spectral resolutions from 6 to 200 kHz. The backend includes a new intermediate-frequency processor, as well as a FPGA-based FFT spectrometer, which manage thousands of spectroscopic channels in real time. All these equipment need to be controlled and operated by a common software, which has to synchronize activities among affected devices, and also with the observing program. The final output should be a calibrated spectrum, readable by standard radio astronomical tools for further processing. The developed software at this end is named "Spectroscopic Data Acquisition Interface" (SDAI). SDAI is written in python 2.5, using PyQt4 for the User Interface. By an ethernet socket connection, SDAI receives astronomical information (source, frequencies, Doppler correction, etc.) and the antenna status from the observing program. Then it synchronizes the observations at the required frequency by tuning the synthesizers through their USB ports; finally SDAI controls the FFT spectrometers through UDP commands sent by sockets. Data are transmitted from the FFT spectrometers by TCP sockets, and written as standard FITS files. In this paper we describe the modules built, depict a typical observing session, and show some astronomical results using SDAI.
Booth, R.
1996-10-08
A quartet of parallel coupled planar triodes is removably mounted in a quadrahedron shaped PCB structure. Releasable brackets and flexible means attached to each triode socket make triode cathode and grid contact with respective conductive coatings on the PCB and a detachable cylindrical conductive element enclosing and contacting the triode anodes jointly permit quick and easy replacement of faulty triodes. By such orientation, the quad pulser can convert a relatively low and broad pulse into a very high and narrow pulse. 16 figs.
Booth, Rex
1996-01-01
A quartet of parallel coupled planar triodes is removably mounted in a quadrahedron shaped PCB structure. Releasable brackets and flexible means attached to each triode socket make triode cathode and grid contact with respective conductive coatings on the PCB and a detachable cylindrical conductive element enclosing and contacting the triode anodes jointly permit quick and easy replacement of faulty triodes. By such orientation, the quad pulser can convert a relatively low and broad pulse into a very high and narrow pulse.
Comparison of Rectified and Unrectified Sockets for Transtibial Amputees.
Engsberg, Jack R; Sprouse, S Wayne; Uhrich, Mary L; Ziegler, Barbara R; Luitjohan, F Daniel
2008-01-01
The current method for fabricating prosthetic sockets is to modify a positive mold to account for the non-homogeneity of the residual limb to tolerate load (i.e., rectified socket). We tested unrectified sockets by retaining the shape of the residual limb, except for a distal end pad, using an alginate gel process instead of casting. This investigation compared rectified and unrectified sockets. Forty-three adults with unilateral transtibial amputations were tested after randomly wearing both rectified and unrectified sockets for at least 4 weeks. Testing included a gait analysis, energy expenditure and Prosthesis Evaluation Questionnaire (PEQ). Results indicated no differences between sockets for gait speed and timing, gait kinematics and kinetics, and gait energy expenditure. There were also no differences in the Prosthetic Evaluation Questionnaire and 16 subjects selected the rectified socket, 25 selected the unrectified socket, and 2 subjects selected to use both sockets as their exit socket. Results seemed to indicate that more than one paradigm exists for shaping prosthetic sockets, and this paradigm may be helpful in understanding the mechanisms of socket fit. The alginate gel fabrication method was simpler than the traditional method. The method could be helpful in other countries where prosthetic care is lacking, may be helpful with new amputees, and may be helpful in typical clinics to reduce costs and free the prosthetist to focus more time on patient needs.
Comparison of Rectified and Unrectified Sockets for Transtibial Amputees
Engsberg, Jack R.; Sprouse, S. Wayne; Uhrich, Mary L.; Ziegler, Barbara R.; Luitjohan, F. Daniel
2008-01-01
The current method for fabricating prosthetic sockets is to modify a positive mold to account for the non-homogeneity of the residual limb to tolerate load (i.e., rectified socket). We tested unrectified sockets by retaining the shape of the residual limb, except for a distal end pad, using an alginate gel process instead of casting. This investigation compared rectified and unrectified sockets. Forty-three adults with unilateral transtibial amputations were tested after randomly wearing both rectified and unrectified sockets for at least 4 weeks. Testing included a gait analysis, energy expenditure and Prosthesis Evaluation Questionnaire (PEQ). Results indicated no differences between sockets for gait speed and timing, gait kinematics and kinetics, and gait energy expenditure. There were also no differences in the Prosthetic Evaluation Questionnaire and 16 subjects selected the rectified socket, 25 selected the unrectified socket, and 2 subjects selected to use both sockets as their exit socket. Results seemed to indicate that more than one paradigm exists for shaping prosthetic sockets, and this paradigm may be helpful in understanding the mechanisms of socket fit. The alginate gel fabrication method was simpler than the traditional method. The method could be helpful in other countries where prosthetic care is lacking, may be helpful with new amputees, and may be helpful in typical clinics to reduce costs and free the prosthetist to focus more time on patient needs. PMID:18776945
Fatone, Stefania; Caldwell, Ryan
2017-01-01
Background: Current transfemoral prosthetic sockets restrict function, lack comfort, and cause residual limb problems. Lower proximal trim lines are an appealing way to address this problem. Development of a more comfortable and possibly functional subischial socket may contribute to improving quality of life of persons with transfemoral amputation. Objectives: The purpose of this study was to (1) describe the design and fabrication of a new subischial socket and (2) describe efforts to teach this technique. Study design: Development project. Methods: Socket development involved defining the following: subject and liner selection, residual limb evaluation, casting, positive mold rectification, check socket fitting, definitive socket fabrication, and troubleshooting of socket fit. Three hands-on workshops to teach the socket were piloted and attended by 30 certified prosthetists and their patient models. Results: Patient models responded positively to the comfort, range of motion, and stability of the new socket while prosthetists described the technique as “straight forward, reproducible.” Conclusion: To our knowledge, this is the first attempt to create a teachable subischial socket, and while it appears promising, more definitive evaluation is needed. Clinical relevance We developed the Northwestern University Flexible Subischial Vacuum (NU-FlexSIV) Socket as a more comfortable alternative to current transfemoral sockets and demonstrated that it could be taught successfully to prosthetists. PMID:28094686
Wernke, Matthew M; Schroeder, Ryan M; Haynes, Michael L; Nolt, Lonnie L; Albury, Alexander W; Colvin, James M
2017-07-01
Objective: Prosthetic sockets are custom made for each amputee, yet there are no quantitative tools to determine the appropriateness of socket fit. Ensuring a proper socket fit can have significant effects on the health of residual limb soft tissues and overall function and acceptance of the prosthetic limb. Previous work found that elevated vacuum pressure data can detect movement between the residual limb and the prosthetic socket; however, the correlation between the two was specific to each user. The overall objective of this work is to determine the relationship between elevated vacuum pressure deviations and prosthetic socket fit. Approach: A tension compression machine was used to apply repeated controlled forces onto a residual limb model with sockets of different internal volume. Results: The vacuum pressure-displacement relationship was dependent on socket fit. The vacuum pressure data were sensitive enough to detect differences of 1.5% global volume and can likely detect differences even smaller. Limb motion was reduced as surface area of contact between the limb model and socket was maximized. Innovation: The results suggest that elevated vacuum pressure data provide information to quantify socket fit. Conclusions: This study provides evidence that the use of elevated vacuum pressure data may provide a method for prosthetists to quantify and monitor socket fit. Future studies should investigate the relationship between socket fit, limb motion, and limb health to define optimal socket fit parameters.
Change in residual limb size over time in the NU-FlexSIV socket: A case study.
Fatone, Stefania; Yohay, Jessica; Caldwell, Ryan
2018-05-01
This case study represented a unique opportunity wherein a long-time user of sub-ischial sockets had kept nearly every socket he wore for a decade. This individual let us borrow these sockets so we could digitize them and indirectly assess change in residual limb size over time by calculating changes in socket volume and circumferences over time. Case Description and Methods: Over a decade, the subject maintained a relatively stable body weight of 84-88 kg and received nine sub-ischial sockets. The internal surface of each socket was scanned using a mechanical digitizer and volume and circumferences calculated. Findings and Outcomes: Socket volume increased 31.3%, from a low of 2659.2 cm 3 for the oldest socket to a high of 3490.6 cm 3 for the most recent socket. Proximal circumferences increased more than distal circumferences with a 15.9% total increase proximally versus 8.9% total increase distally. The results suggest that this individual's residual limb increased in size over time despite the compressive effect of the socket and liner. In addition, the increase in circumference was greater proximally than distally, which is where the remaining muscle bellies are located. Clinical relevance This case study provides insight into the long-term effect of the sub-ischial socket on residual limb volume given compression of the soft tissues by the socket system.
Electrical grounding prong socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leong, R.
1990-01-01
The invention is a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. 17 figs.
Electrical grounding prong socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leong, R.
1990-12-31
The invention is a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. 17 figs.
Electrical grounding prong socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leong, R.
1991-06-18
This patent describes a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket.
Electrical grounding prong socket
Leong, Robert
1991-01-01
The invention is a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket.
Review of the socket design and interface pressure measurement for transtibial prosthesis.
Pirouzi, Gh; Abu Osman, N A; Eshraghi, A; Ali, S; Gholizadeh, H; Wan Abas, W A B
2014-01-01
Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations.
Review of the Socket Design and Interface Pressure Measurement for Transtibial Prosthesis
Pirouzi, Gh.; Abu Osman, N. A.; Eshraghi, A.; Ali, S.; Gholizadeh, H.; Wan Abas, W. A. B.
2014-01-01
Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations. PMID:25197716
Safari, Mohammad Reza; Tafti, Nahid; Aminian, Gholamreza
2015-01-01
The objectives of the current study were to compare intra-socket pressure differences between comfortable and uncomfortable socket conditions, and the usefulness of subject perception of satisfaction, activity limitations, and socket comfort in distinguishing between these two socket conditions. Five unilateral trans-tibial amputees took part in the study. They answered the Socket Comfort Score (SCS) and Trinity Amputation and Prosthetic Experience Scale (TAPES) questionnaires before the interface pressure (in standing and walking) was measured for the uncomfortable socket condition at five regions of the residual limb. Participants were then provided with a comfortable socket and wore it for two weeks. Participants who were satisfied with the socket fit after two weeks repeated the SCS and TAPES questionnaires and interface pressure measurements. The differences between the test results of the two conditions were not statistically significant, except for the interface pressure at the popliteal region during the early stance phase, TAPES socket fit subscale, and the SCS. Due to large variability of the data and the lack of statistical significance, no firm conclusion can be made on the possible relationship between the interface pressure values and the patient-reported outcomes of the two socket conditions. A larger sample size and longer acclimation period are required to locate significant differences.
Dimpled ball grid array process development for space flight applications
NASA Technical Reports Server (NTRS)
Barr, S. L.; Mehta, A.
2000-01-01
A 472 dimpled ball grid array (D-BGA) package has not been used in past space flight environments, therefore it was necessary to develop a process that would yield robust and reliable solder joints. The process developing assembly, inspection and rework techniques, were verified by conducting environmental tests. Since the 472 D-BGA packages passed the above environmental tests within the specifications, the process was successfully developed for space flight electronics.
Subgrain Rotation Behavior in Sn3.0Ag0.5Cu-Sn37Pb Solder Joints During Thermal Shock
NASA Astrophysics Data System (ADS)
Han, Jing; Tan, Shihai; Guo, Fu
2018-01-01
Ball grid array (BGA) samples were soldered on a printed circuit board with Sn37Pb solder paste to investigate the recrystallization induced by subgrain rotation during thermal shock. The composition of the solder balls was Sn3.0Ag0.5Cu-Sn37Pb, which comprised mixed solder joints. The BGA component was cross-sectioned before thermal shock. The microstructure and grain orientations were obtained by a scanning electron microscope equipped with an electron back-scattered diffraction system. Two mixed solder joints at corners of the BGA component were selected as the subjects. The results showed that recrystallization occurred at the corner of the solder joints after 200 thermal shock cycles. The recrystallized subgrains had various new grain orientations. The newly generated grain orientations were closely related to the initial grain orientations, which indicated that different subgrain rotation behaviors could occur in one mixed solder joint with the same initial grain orientation. When the misorientation angles were very small, the rotation axes were about Sn [100], [010] and [001], as shown by analyzing the misorientation angles and subgrain rotation axes, while the subgrain rotation behavior with large misorientation angles in the solder joints was much more complicated. As Pb was contained in the solder joints and the stress was concentrated on the corner of the mixed solder joints, concaves and cracks were formed. When the adjacent recrystallized subgrains were separated, and the process of the continuous recrystallization was limited.
Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek; Colvin, James M
2012-01-01
A prosthesis encounters loading through forces and torques exerted by the person with amputation. International Organization for Standardization (ISO) standard 10328 was designed to test most lower-limb prosthetic components. However, this standard does not include prosthetic sockets. We measured static failure loads of prosthetic sockets using a modified ISO 10328 and then compared them with the criteria set by this standard for other components. Check socket (CS) strengths were influenced by thickness, material choice, and fabrication method. Copolymer socket (CP) strengths depended on thickness and fabrication methods. A majority of the CSs and all of the CPs failed to pass the ISO 10328 ductile loading criterion. In contrast, the strengths of definitive laminated sockets (DLs) were influenced more by construction material and technique. A majority of the DLs failed to pass the ISO 10328 brittle loading criterion. Analyzing prosthetic sockets from a variety of facilities demonstrated that socket performance varies considerably between and within facilities. The results from this article provide a foundation for understanding the quality of prosthetic sockets, some insight into possible routes for improving the current care delivered to patients, and a comparative basis for future technology.
Wernke, Matthew M.; Schroeder, Ryan M.; Haynes, Michael L.; Nolt, Lonnie L.; Albury, Alexander W.; Colvin, James M.
2017-01-01
Objective: Prosthetic sockets are custom made for each amputee, yet there are no quantitative tools to determine the appropriateness of socket fit. Ensuring a proper socket fit can have significant effects on the health of residual limb soft tissues and overall function and acceptance of the prosthetic limb. Previous work found that elevated vacuum pressure data can detect movement between the residual limb and the prosthetic socket; however, the correlation between the two was specific to each user. The overall objective of this work is to determine the relationship between elevated vacuum pressure deviations and prosthetic socket fit. Approach: A tension compression machine was used to apply repeated controlled forces onto a residual limb model with sockets of different internal volume. Results: The vacuum pressure–displacement relationship was dependent on socket fit. The vacuum pressure data were sensitive enough to detect differences of 1.5% global volume and can likely detect differences even smaller. Limb motion was reduced as surface area of contact between the limb model and socket was maximized. Innovation: The results suggest that elevated vacuum pressure data provide information to quantify socket fit. Conclusions: This study provides evidence that the use of elevated vacuum pressure data may provide a method for prosthetists to quantify and monitor socket fit. Future studies should investigate the relationship between socket fit, limb motion, and limb health to define optimal socket fit parameters. PMID:28736683
29 CFR Appendix II to Part 1918 - Tables for Selected Miscellaneous Auxiliary Gear (Mandatory)
Code of Federal Regulations, 2010 CFR
2010-07-01
... (IWRC), use vales in HT (FC) columns. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1... HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Notes: (1) These... values in HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1) These...
29 CFR Appendix II to Part 1918 - Tables for Selected Miscellaneous Auxiliary Gear (Mandatory)
Code of Federal Regulations, 2014 CFR
2014-07-01
... (IWRC), use vales in HT (FC) columns. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1... HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Notes: (1) These... values in HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1) These...
29 CFR Appendix II to Part 1918 - Tables for Selected Miscellaneous Auxiliary Gear (Mandatory)
Code of Federal Regulations, 2012 CFR
2012-07-01
... (IWRC), use vales in HT (FC) columns. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1... HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Notes: (1) These... values in HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1) These...
29 CFR Appendix II to Part 1918 - Tables for Selected Miscellaneous Auxiliary Gear (Mandatory)
Code of Federal Regulations, 2011 CFR
2011-07-01
... (IWRC), use vales in HT (FC) columns. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1... HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Notes: (1) These... values in HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1) These...
29 CFR Appendix II to Part 1918 - Tables for Selected Miscellaneous Auxiliary Gear (Mandatory)
Code of Federal Regulations, 2013 CFR
2013-07-01
... (IWRC), use vales in HT (FC) columns. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1... HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Notes: (1) These... values in HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1) These...
Tribology approach to the engineering and study of articular cartilage.
Wimmer, Markus A; Grad, Sibylle; Kaup, Thomas; Hänni, Markus; Schneider, Erich; Gogolewski, Sylwester; Alini, Mauro
2004-01-01
This study has been based on the assumption that articular motion is an important aspect of mechanotransduction in synovial joints. For this reason a new bioreactor concept, able to reproduce joint kinematics more closely, has been designed. The prototype consists of a rotating scaffold and/or cartilage pin, which is pressed onto an orthogonally rotating ball. By oscillating pin and ball in phase difference, elliptical displacement trajectories are generated that are similar to the motion paths occurring in vivo. Simultaneously, dynamic compression may be applied with a linear actuator, while two-step-motors generate the rotation of pin and ball. The whole apparatus is placed in an incubator. The control station is located outside. Preliminary investigations at the gene expression level demonstrated promising results. Compared with free-swelling control and/or simply compression-loaded samples, chondrocyte-seeded scaffolds as well as nasal cartilage explants exposed to interface motion both showed elevated levels of cartilage oligomeric matrix protein mRNA. The final design of the bioreactor will include four individual stations in line, which will facilitate the investigation of motion-initiated effects at the contacting surfaces in more detail.
NASA Technical Reports Server (NTRS)
Barry, Matthew R.
2006-01-01
The X-Windows Socket Widget Class ("Class" is used here in the object-oriented-programming sense of the word) was devised to simplify the task of implementing network connections for graphical-user-interface (GUI) computer programs. UNIX Transmission Control Protocol/Internet Protocol (TCP/IP) socket programming libraries require many method calls to configure, operate, and destroy sockets. Most X Windows GUI programs use widget sets or toolkits to facilitate management of complex objects. The widget standards facilitate construction of toolkits and application programs. The X-Windows Socket Widget Class encapsulates UNIX TCP/IP socket-management tasks within the framework of an X Windows widget. Using the widget framework, X Windows GUI programs can treat one or more network socket instances in the same manner as that of other graphical widgets, making it easier to program sockets. Wrapping ISP socket programming libraries inside a widget framework enables a programmer to treat a network interface as though it were a GUI.
Holder for rotating glass body
Kolleck, Floyd W.
1978-04-04
A device is provided for holding and centering a rotating glass body such as a rod or tube. The device includes a tubular tip holder which may be held in a lathe chuck. The device can utilize a variety of centering tips each adapted for a particular configuration, such as a glass O-ring joint or semi-ball joint.
Motion analysis of throwing Boccia balls in children with cerebral palsy.
Huang, Po-Chang; Pan, Po-Jung; Ou, Yu-Chih; Yu, Yi-Chen; Tsai, Yung-Shen
2014-02-01
Boccia is a sport suitable for children with cerebral palsy (CP). Throwing Boccia balls requires upper extremity and torso coordination. This study investigated the differences between children with CP and normally developed children regarding throwing patterns of Boccia balls. Thirteen children with bilateral spastic CP and 20 normally developed children participated in this study. The tests in this study were a pediatric reach test and throwing of Boccia balls. A 3D electromagnetic motion tracking system and a force plate were synchronized to record and analyze biomechanical parameters of throwing Boccia balls. The results of the pediatric reach test for participants with CP were significantly worse than those for normally developed participants. The 2 groups of participants did not significantly differ regarding the distance between a thrown Boccia ball and a target ball (jack). Participants with CP demonstrated significantly longer movement duration, smaller amplitude of elbow movement, greater amplitudes of shoulder abduction and flexion, slower maximal velocity of torso flexion and the linear velocity of moving the wrist joint forward, faster maximal velocity of head flexion, and smaller sway ratio compared with normally developed participants when throwing Boccia balls. Participants with CP seemed to mainly use head and shoulder movements to bring the Boccia balls forward with limited torso movement. Normally developed participants brought the Boccia ball forward with faster torso and greater elbow movement while stabilizing head and shoulder movements. Nevertheless, participants with CP did not demonstrate significantly worse performance in the throwing accuracy of Boccia balls. Copyright © 2013 Elsevier Ltd. All rights reserved.
Hachisuka, K; Matsushima, Y; Ohmine, S; Shitama, H; Shinkoda, K
2001-09-01
The purpose of this study was to examine the moisture permeability properties of materials used for total surface bearing (TSB) socket with a silicone liner, a combination of Silicone Suction Socket or Icelandic Roll-On Silicone Socket (ICEROSS) and an acrylic plastic sheet (Degaplast), patella-tendon bearing (PTB) socket, a combination of Pe-Lite and Degaplast, and wooden socket made of poplar. Moisture permeability of the socket materials was measured as the diminution of water in a container after 12 hours in a climatic chamber. Eight containers with their open, top side were uncovered (no material) or sealed with one of the socket materials; the experiment was repeated four times. One-way analysis of variance followed by Bonferroni's test was applied to examine the differences in moisture permeability. Moisture permeability levels were as follows: no material, 85.9 +/- 1.3 g; poplar, 4.3 +/- 0.4 g; Silicone Suction Socket, 1.1 +/- 0.2 g; ICEROSS, 1.0 +/- 0.2 g; Pe-Lite, 0.8 +/- 0.1 g; 3S + Degaplast, 0.8 +/- 0.1 g; ICEROSS + Degaplast, 0.8 +/- 0.2 g; and Pe-Lite + Degaplast, 0.8 +/- 0.1 g. There were significant differences between the uncovered container and the others, and between poplar and the others (P < 0.05). We concluded that the TSB socket with a silicone liner is not superior to the PTB socket with regard to moisture permeability, and that it is necessary to develop a new prosthetic socket that allows heat release and drainage of sweat.
Sandhu, Jaspal S; Mahajan, Shruti; Shenoy, Shweta
2008-04-01
Numerous exercises are used to strengthen muscles around the shoulder joint including the push-up and the push-up plus. An important consideration is the addition of surface instability in the form of swiss ball for rehabilitation and strength. The justification for the use of the swiss ball is based on its potential for increasing muscular demand required to maintain postural stability and for improving joint proprioception. Evidence for this is lacking in literature. To compare the myoelectric amplitude of shoulder muscles during push-ups on labile and stable surface. Same subject experimental study. Thirty healthy male subjects in the age group 20-30 years with a mean height of 173.65 cm (+/- SD 2.56) and a mean weight of 69.9 kg (+/-SD 0.2) were taken. Surface electromyogram was recorded from triceps, pectoralis major, serratus anterior and upper trapezius while performing push-up and push-up plus exercises, both on labile and stable surface. Significant increase in muscle activity was observed in pectoralis major and triceps muscle (only during eccentric phase of elbow pushups), while serratus anterior and upper trapezius showed no change in activation level on swiss ball. The addition of a swiss ball is capable of influencing shoulder muscle activity during push-up variations, although the effect is task and muscle dependent.
2016-10-01
satisfaction with device’’ (i.e. prosthesis) than the IC Socket. During year 1, we received all required IRB approvals, registered the clinical... satisfaction with device” (i.e. prosthesis) than the IC Socket. 2. KEYWORDS: Prosthetic Socket, Artificial Limbs, Prosthesis, Transfemoral Amputee, Gait...FlexSIV Socket will result in better quality of life and “ satisfaction with device” (i.e. prosthesis) than the IC socket. Accomplishments under
Reusable Solid Rocket Motor Nozzle Joint 5 Redesign
NASA Technical Reports Server (NTRS)
Lui, R. C.; Stratton, T. C.; LaMont, D. T.
2003-01-01
Torque tension testing of a newly designed Reusable Solid Rocket Motor nozzle bolted assembly was successfully completed. Test results showed that the 3-sigma preload variation was as expected at the required input torque level and the preload relaxation were within the engineering limits. A shim installation technique was demonstrated as a simple process to fill a shear lip gap between nozzle housings in the joint region. A new automated torque system was successfully demonstrated in this test. This torque control tool was found to be very precise and accurate. The bolted assembly performance was further evaluated using the Nozzle Structural Test Bed. Both current socket head cap screw and proposed multiphase alloy bolt configurations were tested. Results indicated that joint skip and bolt bending were significantly reduced with the new multiphase alloy bolt design. This paper summarizes all the test results completed to date.
Effect of alignment perturbations in a trans-tibial prosthesis user: A pilot study.
Courtney, Anna; Orendurff, Michael S; Buis, Arjan
2016-04-01
A recurring complication in trans-tibial prosthetic limb users is "poor socket fit" with painful residuum-socket interfaces, a consequence of excess pressure. This is due to both poor socket fit and poor socket alignment; however, the interaction of these factors has not been quantified. Through evaluation of kinetic data this study aimed to articulate an interaction uniting socket design, alignment and interface pressures. The results will help to refine future studies and will hopefully help determine whether sockets can be designed, fitted and aligned to maximize mobility whilst minimizing injurious forces. Interface pressures were recorded throughout ambulation in one user with "optimal (reference) alignment" followed by 5 malalignments in a patellar tendon-bearing and a hydrocast socket. Marked differences in pressure distribution were discovered when equating the patellar tendon-bearing against the hydrocast socket and when comparing interface pressures from reference with offset alignment. Patellar tendon-bearing sockets were found to be more sensitive to alignment perturbations than hydrocast sockets. A complex interaction was found, with the most prominent finding demonstrating the requisite for attainment of optimal alignment: a translational alignment error of 10 mm can increase maximum peak pressures by 227% (mean 17.5%). Refinements for future trials are described and the necessity for future research into socket design, alignment and interface pressures has been estabilished.
Comparison of dominant hand range of motion among throwing types in baseball pitchers.
Wang, Lin-Hwa; Kuo, Li-Chieh; Shih, Sheng-Wen; Lo, Kuo-Cheng; Su, Fong-Chin
2013-08-01
Previous research on baseball pitchers' wrists, elbows, and should joints contributes to our understanding of pitchers' control over delicate joint motion and ball release. However, limited research on forearm, wrist, and hand joints prevents full comprehension of the throwing mechanism. The present descriptive laboratory study quantifies angular performances of hand and wrist joints while pitching breaking balls, including fastballs, curveballs and sliders, among pitchers with different skill levels. Nineteen baseball pitchers performed required pitching tasks (10 from university and 9 from high school). A three-dimensional motion analysis system collected pitching motion data. The range of joint motion in the wrist and proximal interphalangeal (PIP) and metacarpophalangeal (MP) joints of the index and middle fingers were compared among fastballs, curveballs and sliders. Thirteen reflective markers were placed on selected anatomic landmarks of the wrist, middle and index fingers of the hand. Wrist flexion angle in the pitching acceleration phase was larger in fastballs (20.58±4.07°) and sliders (22.48±5.45°) than in curveballs (9.08±3.03°) (p = .001). The flexion angle of the PIP joint was significantly larger in curveballs (38.5±3.8°) than in fastballs (30.3±4.8°) and sliders (30.2±4.5°) (p=.004) of the middle finger. Abduction angle of MP joint on the middle finger was significantly larger in curveballs (15.4 ±3.6°) than in fastballs (8.9±1.2°) and sliders (6.9±2.9°) (p=.001) of the middle finger, and the abduction angle of index finger was significantly larger in sliders (13.5±15.0°) than in fastballs (7.2 ±2.8°) (p=.007). Hand and wrist motion and grip types affect the relative position between fingers and ball, which produces different types of baseball pitches. A larger extension angle of the wrist joint and the coordination of middle and index fingers are crucial when pitching a fastball. Abduction and flexion movement on the MP joint of the middle finger are important for a curveball. MP joint abduction and flexion movement of the index finger produce sliders. Understanding the control mechanism in a throwing hand can help improve training protocols in either injury prevention or performance improvement for baseball pitchers. Copyright © 2013 Elsevier B.V. All rights reserved.
Healing of ungrafted and grafted extraction sockets after 12 weeks: a prospective clinical study.
Heberer, Susanne; Al-Chawaf, Bassem; Jablonski, Carlo; Nelson, John J; Lage, Hermann; Nelson, Katje
2011-01-01
In this prospective study, bone formation in human extraction sockets augmented with Bio-Oss Collagen after a 12-week healing period was quantified and compared to bone formation in unaugmented extraction sockets. Selected patients with four-walled extraction sockets were included in this prospective study. After extraction, the sockets were randomly augmented using Bio-Oss Collagen or left to heal unfilled without raising a mucoperiosteal flap. At the time of implant placement, histologic specimens were obtained from the socket and analyzed. Statistical analysis was performed using the Wilcoxon signed-rank test. Twenty-five patients with a total of 39 sockets (20 augmented, 19 unaugmented) were included in the study and the histologic specimens analyzed. All specimens were free of inflammatory cells. The mean overall new bone formation in the augmented sites was 25% (range, 8%-41%) and in the unaugmented sockets it was 44% (range, 3%-79%). There was a significant difference in the rate of new bone formation between the grafted and ungrafted sockets and a significant difference in the bone formation rate in the apical compared to the coronal regions of all sockets, independent of the healing mode. This descriptive study demonstrated that bone formation in Bio-Oss Collagen-grafted human extraction sockets was lower than bone formation in ungrafted sockets. Bone formation occurred in all specimens with varying degrees of maturation independent of the grafting material and was initiated from the apical region.
Mahesh, Lanka; Narayan, Tv; Kostakis, Georgios; Shukla, Sagrika
2014-03-01
To measure implant stability using periotest values of implants placed in sockets augmented with calcium phospho-silicate putty (CPS Putty) as compared with implant stability in naturally healed sockets. Twenty two sockets were implanted with CPS Putty immediately after extraction. The sockets were re-entered after a healing period at 5 to 6 months (average 5.3 months) for implant placement. Periotest values were recorded during implant insertion to assess primary stability. These were compared with the Periotest values of 26 implants placed in 22 patients, with naturally healed sockets. Periotest values were significantly lower in the grafted group, indicating better implant stability in sites grafted with CPS putty. Implant stability seems to be significantly higher in sockets augmented using CPS putty when compared to nongrafted sites. This suggests that socket grafting with CPS putty may enhance the quality of available bone for implantation.
Al-Fakih, Ebrahim A; Abu Osman, Noor Azuan; Mahmad Adikan, Faisal Rafiq
2016-07-20
The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket.
Al-Fakih, Ebrahim A.; Abu Osman, Noor Azuan; Mahmad Adikan, Faisal Rafiq
2016-01-01
The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket. PMID:27447646
Thermal Cycling Life Prediction of Sn-3.0Ag-0.5Cu Solder Joint Using Type-I Censored Data
Mi, Jinhua; Yang, Yuan-Jian; Huang, Hong-Zhong
2014-01-01
Because solder joint interconnections are the weaknesses of microelectronic packaging, their reliability has great influence on the reliability of the entire packaging structure. Based on an accelerated life test the reliability assessment and life prediction of lead-free solder joints using Weibull distribution are investigated. The type-I interval censored lifetime data were collected from a thermal cycling test, which was implemented on microelectronic packaging with lead-free ball grid array (BGA) and fine-pitch ball grid array (FBGA) interconnection structures. The number of cycles to failure of lead-free solder joints is predicted by using a modified Engelmaier fatigue life model and a type-I censored data processing method. Then, the Pan model is employed to calculate the acceleration factor of this test. A comparison of life predictions between the proposed method and the ones calculated directly by Matlab and Minitab is conducted to demonstrate the practicability and effectiveness of the proposed method. At last, failure analysis and microstructure evolution of lead-free solders are carried out to provide useful guidance for the regular maintenance, replacement of substructure, and subsequent processing of electronic products. PMID:25121138
Mapping the Future: Optimizing Joint Geospatial Engineering Support
2006-05-16
Environment. Maxwell Air Force Base, AL.: Air University, 1990. Babbage , Ross and Desmond Ball. Geographic Information Systems: Defence Applications...Joint Pub 4-04. Washington, DC: 27 September 2001. Wertz, Charles J. The Data Dictionary, Concepts and Uses. Wellesley, MA: QED Information...Force Defense Mapping for Future Operations, Washington, DC: September 1995, 1-7. 18 Charles J. Wertz, The Data Dictionary, Concepts and Uses
van den Tillaar, R; Zondag, A; Cabri, J
2013-12-01
The aim of this study was to compare the performance (throwing velocity of the ball) and kinematics of overarm throwing with the circular and whip-like wind up in elite handball players. Twenty-two elite handball players (11 men and 11 women) conducted both types of throws. The ball release velocity, maximal ball acceleration, maximal velocity of the end points of the five segments and maximal angles, angles at ball release and maximal angular velocities of the 11 joint movements and their timing during the throw were analyzed. Significantly higher ball release velocities (21.9 m/s vs 20.6 m/s) were reached together with higher maximal linear velocities of the end points of all segments and longer throwing time with the circular wind up than with the whip-like wind up. Furthermore, it seems that the timing and amount of maximal angular pelvis rotation was the main contributor to the difference in the maximal ball release velocity between the two wind ups. The findings support the observation that overarm throwing with the circular wind up results in higher ball releases but also a longer throwing movement in comparison to whip-like wind up throws. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Oyama, Sakiko; Yu, Bing; Blackburn, J Troy; Padua, Darin A; Li, Li; Myers, Joseph B
2014-09-01
In a properly coordinated throwing motion, peak pelvic rotation velocity is reached before peak upper torso rotation velocity, so that angular momentum can be transferred effectively from the proximal (pelvis) to distal (upper torso) segment. However, the effects of trunk rotation sequence on pitching biomechanics and performance have not been investigated. The aim of this study was to investigate the effects of trunk rotation sequence on ball speed and on upper extremity biomechanics that are linked to injuries in high school baseball pitchers. The hypothesis was that pitchers with improper trunk rotation sequence would demonstrate lower ball velocity and greater stress to the joint. Descriptive laboratory study. Three-dimensional pitching kinematics data were captured from 72 high school pitchers. Subjects were considered to have proper or improper trunk rotation sequences when the peak pelvic rotation velocity was reached either before or after the peak upper torso rotation velocity beyond the margin of error (±3.7% of the time from stride-foot contact to ball release). Maximal shoulder external rotation angle, elbow extension angle at ball release, peak shoulder proximal force, shoulder internal rotation moment, and elbow varus moment were compared between groups using independent t tests (α < 0.05). Pitchers with improper trunk rotation sequences (n = 33) demonstrated greater maximal shoulder external rotation angle (mean difference, 7.2° ± 2.9°, P = .016) and greater shoulder proximal force (mean difference, 9.2% ± 3.9% body weight, P = .021) compared with those with proper trunk rotation sequences (n = 22). No other variables differed significantly different between groups. High school baseball pitchers who demonstrated improper trunk rotation sequences demonstrated greater maximal shoulder external rotation angle and shoulder proximal force compared with pitchers with proper trunk rotation sequences. Improper sequencing of the trunk and torso alter upper extremity joint loading in ways that may influence injury risk. As such, exercises that reinforce the use of a proper trunk rotation sequence during the pitching motion may reduce the stress placed on the structures around the shoulder joint and lead to the prevention of injuries. © 2014 The Author(s).
Mohd Hawari, Nurhanisah; Jawaid, Mohammad; Md Tahir, Paridah; Azmeer, Raja Ahmad
2017-11-01
The aim of this case study was to explore patient satisfaction with the quality of prosthetic leg sockets intended for persons with lower limb amputations. A qualitative study based on in-depth interviews, preceded by a questionnaire session, was carried out with patients from the Rehabilitation Center and Hospital in Malaysia. Twelve out-patient and in-patient amputees with lower limb amputations, specifically below-knee amputations, were chosen randomly. The analysis of patients' narratives aimed to identify the functional and esthetic characteristics of currently used prosthetic leg sockets and any problems related to them. The obtained results indicated that out of the 12 participants, 41.7% and 25% were satisfied and somewhat satisfied with their current prosthetic sockets. Durability and comfort were rated by the participants as the most important characteristics of prosthetic sockets, with 83.3%. As regards the esthetic appearance of the socket, 66.7% of the respondents considered that the most important feature was the material from which the socket was fabricated. Thus, we conclude that current satisfaction levels with the quality of prosthetic sockets among amputees in Malaysia are suitable, prosthesis being preferred by many amputees. The results can be used to direct future research on cosmesis and functionality of prosthetic socket design. Implications for Rehabilitation Case study will help participants to get cost effective prosthetic leg socket. Develop prosthetic leg socket comfortable as comparative to existing one. Help Malaysian government to make policy to develop local prosthetic leg socket at affordable price.
Laing, Sheridan; Lythgo, Noel; Lavranos, Jim; Lee, Peter Vee Sin
2017-10-01
This study compared the physical function and comfort level of patients with unilateral transtibial amputation after being fitted with a hand-cast Patella Tendon Bearing (PTB) socket and a pressure-cast (PCAST) hydrocast socket. The latter technique aims to reduce the skill dependency currently required for socket manufacture and fit. The study was conducted at the Vietnamese Training Centre for Orthopaedic Technologies and involved seventeen Vietnamese participants with unilateral transtibial amputation, all of whom were long term users of prosthetics. All participants were fitted with two sockets manufactured using both hand-cast and PCAST techniques with International Committee of the Red Cross components. Walking tests (timed up and go test and six-minute-walk-test), spatio-temporal gait analyses and subjective comfort assessments were completed after a short acclimatisation period with each socket. The participant-preferred socket was also noted. No significant differences were found for the measures of mobility, functional capacity, spatio-temporal gait parameters, gait symmetry, perceived comfort or participant socket preference. The results show the initial patient outcomes are similar when participants are fitted with a hand-cast PTB socket and a PCAST hydrocast sockets. Future work should confirm these findings in a longer trial. Copyright © 2017 Elsevier B.V. All rights reserved.
Kahle, Jason T.; Klenow, Tyler D.; Highsmith, M. Jason
2016-01-01
The socket-limb interface is vital for functionality and provides stability and mobility for the amputee. Volume fluctuation can lead to compromised fit and function. Current socket technology does not accommodate for volume fluctuation. An adjustable interface may improve function and comfort by filling this technology gap. The purpose of this study was to compare the effectiveness of the standard of care (SOC) ischial ramus containment to an adjustable transfemoral prosthetic interface socket in the accommodation of volume fluctuation. A prospective experimental case study using repeated measures of subjective and performance outcome measures between socket conditions was employed. In the baseline volume condition, the adjustable socket improved subjective and performance measures 19% to 37% over SOC, whereas the two-minute walk test demonstrated equivalence. In the volume loss condition, the adjustable socket improved all subjective and performance measures 22% to 93%. All aggregated data improved 16% to 50% compared with the SOC. In simulated volume gain, the SOC socket failed, while the subject was able to complete the protocol using the adjustable socket. In this case study, the SOC socket was inferior to the comparative adjustable transfemoral amputation interface in subjective and performance outcomes. There is a lack of clinical trials and evidence comparing socket functional outcomes related to volume fluctuation. PMID:28066526
Crystal-Packing Trends for a Series of 6,9,12,15,18-Pentaaryl-1-hydro[60]fullerenes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, Robert D.; Halim, Merissa; Khan, Saeed I.
2012-06-11
The relationship between the size of the substituents of aryl groups in a series of fifteen 6,9,12,15,18-pentaaryl-1-hydro[60]fullerenes and the solid-state structures and packing motifs of these compounds has been analyzed. Pentaarylfullerenes have a characteristic “badminton shuttlecock” shape that causes several derivatives to crystallize into columnar stacks. However, many pentaarylfullerenes form non-stacked structures with, for example, dimeric, layered, diamondoid, or feather-in-cavity relationships between molecules. Computational modeling gave a qualitative estimate of the best shape match between the ball and socket surfaces of each pentaarylfullerene. The best match was for pentaarylfullerenes with large, spherically shaped para-substituents on the aryl groups. The seriesmore » of pentaarylfullerenes was characterized by single-crystal X-ray diffraction. A total of 34 crystal structures were obtained as various solvates and were categorized by their packing motifs.« less
Alveolar osteitis; Alveolitis; Septic socket ... You may be more at risk for dry socket if you: Have poor oral health Have a ... after having a tooth pulled Have had dry socket in the past Drink from a straw after ...
Komatsu, Teruya; Sakaguchi, Yasuto; Muranishi, Yusuke; Yutaka, Yojiro; Date, Hiroshi; Nakamura, Tatsuo
2018-01-01
Background Costal coaptation pins made of poly-L-lactide (PLA) are clinically available for fixing surgically divided ribs. However, the clinical results of such rib fixation have not been completely satisfactory. We aimed to develop a new rib coaptation socket system and explore its clinical applicability. Methods We surgically divided three consecutive ribs of each beagle dog, and rib coaptation sockets were implanted to stabilize each rib. Fifteen 3-dimensional (3D)-printed and 30 PLA fiber knitted sockets were implanted in five and ten dogs, respectively, to stabilize the artificially divided ribs. Mechanical analysis of the sockets and radiographical examination of costal fixation were performed to evaluate the effectiveness of the newly developed socket system for rib stabilization. Results All 15 ribs with 3D-printed sockets had displaced 1 month after the operation. Three ribs in one dog with implanted PLA fiber knitted sockets were displaced radiographically after 1 month, and the grade of displacement remained unchanged after 6 months. The remaining 27 ribs fixed with PLA fiber knitted sockets did not show any displacement. Conclusions The PLA fiber knitted rib coaptation socket system was sufficiently durable for the stabilization of divided ribs with biocompatibility. This promising finding can be applied for clinical stabilization of divided ribs. PMID:29850125
Komatsu, Teruya; Sato, Toshihiko; Sakaguchi, Yasuto; Muranishi, Yusuke; Yutaka, Yojiro; Date, Hiroshi; Nakamura, Tatsuo
2018-04-01
Costal coaptation pins made of poly-L-lactide (PLA) are clinically available for fixing surgically divided ribs. However, the clinical results of such rib fixation have not been completely satisfactory. We aimed to develop a new rib coaptation socket system and explore its clinical applicability. We surgically divided three consecutive ribs of each beagle dog, and rib coaptation sockets were implanted to stabilize each rib. Fifteen 3-dimensional (3D)-printed and 30 PLA fiber knitted sockets were implanted in five and ten dogs, respectively, to stabilize the artificially divided ribs. Mechanical analysis of the sockets and radiographical examination of costal fixation were performed to evaluate the effectiveness of the newly developed socket system for rib stabilization. All 15 ribs with 3D-printed sockets had displaced 1 month after the operation. Three ribs in one dog with implanted PLA fiber knitted sockets were displaced radiographically after 1 month, and the grade of displacement remained unchanged after 6 months. The remaining 27 ribs fixed with PLA fiber knitted sockets did not show any displacement. The PLA fiber knitted rib coaptation socket system was sufficiently durable for the stabilization of divided ribs with biocompatibility. This promising finding can be applied for clinical stabilization of divided ribs.
Flügge, Tabea; Nelson, Katja; Nack, Claudia; Stricker, Andres; Nahles, Susanne
2015-04-01
This study identified the soft tissue changes of the alveolar ridge at different time points within 12 weeks after tooth extraction with and without socket augmentation. In 38 patients with single tooth extractions, 40 sockets were augmented and 39 extraction sockets were not augmented. At 2, 4, 6, 8 and 12 weeks impressions were taken and casts digitized with a laser scanner. The horizontal and vertical changes were compared between augmented and non-augmented sites. A p-value <0.05 was considered statistically significant. The mean changes of augmented sockets were between 0.4 mm (2 weeks) and 0.8 mm (12 weeks). In non-augmented sockets changes of 0.7 mm (2 weeks) and of 1.0 mm (12 weeks) were demonstrated. The mean values differed significantly between the buccal and oral region (p < 0.01). Overall, there were significant differences of the mean dimensional changes regarding time (p < 0.01) and augmentation (p < 0.01). Augmented sockets showed less resorption within 4 weeks after extraction compared to non-augmented sockets. Non-augmented sockets showed a continuous dimensional loss with a great variation over 12 weeks whereas augmented sockets had the highest degree of resorption between 4 and 6 weeks. At 12 weeks a comparable resorption in augmented and non-augmented sockets was observed. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Continuity tester screens out faulty socket connections
NASA Technical Reports Server (NTRS)
Golding, G.
1964-01-01
A device, used before and after assembly, tests the continuity of an electrical circuit through each pin and socket of multiple connector sockets. Electrically insulated except at the contact area, a test probe is dimensioned to make contact only in properly formed sockets.
A retrospective study on the use of a dental dressing to reduce dry socket incidence in smokers.
Murph, James T; Jaques, Susan H; Knoell, Alexander N; Archibald, Geoffrey D; Yang, Stan
2015-01-01
This study assessed the effectiveness of using an oxidized cellulose dental dressing in order to reduce the rate of alveolar osteitis after posterior tooth extraction in smokers. Dry socket incidences of heavy smokers from 4 independent dental clinics, which routinely used oxidized cellulose dental dressings to mitigate dry socket formation between March 2011 and December 2012, were compiled and evaluated. All extraction sites healed uneventfully except for those cases that developed dry sockets. Overall, 1.7% of male patients and 2.2% of female patients developed dry sockets. No conclusive relationship was found between the number of cigarettes smoked and dry socket formation among patients in this study. The results of this study were consistent with the view that gender, age, postextraction regimen, and multiple extractions affect dry socket formation. The results indicate that an oxidized cellulose dental dressing postextraction is a safe and effective method for mitigating dry socket formation among smokers.
Darter, Benjamin J; Sinitski, Kirill; Wilken, Jason M
2016-10-01
Elevated vacuum suspension systems use a pump to draw air from the socket with the intent of reducing bone-socket motion as compared to passive suction systems. However, it remains unknown if elevated vacuum suspension systems decrease limb displacement uniformly during transitions from unloaded to full-body-weight support. To compare limb-socket motion between elevated vacuum and passive suction suspension sockets using a controlled loading paradigm. Comparative analysis. Persons with transtibial amputation were assessed while wearing either an elevated vacuum or passive suction suspension socket. Digital video fluoroscopy was used to measure axial bone-socket motion while the limb was loaded in 20% body-weight increments. An analysis of variance model was used to compare between suspension types. Total axial displacement (0%-100% body weight) was significantly lower using the elevated vacuum (vacuum: 1.3 cm, passive suction: 1.8 cm; p < 0.0001). Total displacement decreased primarily due to decreased motion during initial loading (0%-20%; p < 0.0001). Other body-weight intervals were not significantly different between systems. Elevated vacuum suspension reduced axial limb-socket motion by maintaining position of the limb within the socket during unloaded conditions. Elevated vacuum provided no meaningful improvement in limb-socket motion past initial loading. Excessive bone-socket motion contributes to poor residual limb health. Our results suggest elevated vacuum suspensions can reduce this axial displacement. Visual assessment of the images suggests that this occurs through the reduction or elimination of the air pocket between the liner and socket wall while the limb is unloaded. © The International Society for Prosthetics and Orthotics 2015.
Dry socket: incidence, clinical features, and predisposing factors.
Akinbami, Babatunde O; Godspower, Thikan
2014-01-01
Background. Dry socket is a global phenomenon. The purpose of the study was to investigate the incidence of dry socket in recent times in a Nigerian Tertiary Hospital. Methods. Patients who were referred for dental extractions were included in the study. The case files of patients were obtained and information retrieved included biodata, indication for extraction, number and type of teeth extracted, oral hygiene status, compliance to oral hygiene instructions, and development of dry socket. Results. One thousand, one hundred and eighty two patients with total of 1362 teeth extracted during the 4-year period of the study were analyzed, out of which 1.4% teeth developed dry socket. The mean age (SD) was 35.2 (16.0) years. Most of the patients who presented with dry socket were in the fourth decade of life. Mandibular teeth were affected more than maxillary teeth. Molars were more affected. Retained roots and third molars were conspicuous in the cases with dry socket. Conclusion. The incidence of dry socket in our centre was lower than previous reports. Oral hygiene status, lower teeth, and female gender were significantly associated with development of dry socket. Treatment with normal saline irrigation and ZnO eugenol dressings allowed relief of the symptoms.
Dry Socket: Incidence, Clinical Features, and Predisposing Factors
Akinbami, Babatunde O.; Godspower, Thikan
2014-01-01
Background. Dry socket is a global phenomenon. The purpose of the study was to investigate the incidence of dry socket in recent times in a Nigerian Tertiary Hospital. Methods. Patients who were referred for dental extractions were included in the study. The case files of patients were obtained and information retrieved included biodata, indication for extraction, number and type of teeth extracted, oral hygiene status, compliance to oral hygiene instructions, and development of dry socket. Results. One thousand, one hundred and eighty two patients with total of 1362 teeth extracted during the 4-year period of the study were analyzed, out of which 1.4% teeth developed dry socket. The mean age (SD) was 35.2 (16.0) years. Most of the patients who presented with dry socket were in the fourth decade of life. Mandibular teeth were affected more than maxillary teeth. Molars were more affected. Retained roots and third molars were conspicuous in the cases with dry socket. Conclusion. The incidence of dry socket in our centre was lower than previous reports. Oral hygiene status, lower teeth, and female gender were significantly associated with development of dry socket. Treatment with normal saline irrigation and ZnO eugenol dressings allowed relief of the symptoms. PMID:24987419
Mitton, Kay; Kulkarni, Jai; Dunn, Kenneth William; Ung, Anthony Hoang
2017-10-01
This novel case report describes the problems of prescribing a prosthetic socket in a left transfemoral amputee secondary to chronic patellofemoral instability compounded by complex regional pain syndrome. Case Description and Methods: Following the amputation, complex regional pain syndrome symptoms recurred in the residual limb, presenting mainly with oedema. Due to extreme daily volume fluctuations of the residual limb, a conventional, laminated thermoplastic socket fitting was not feasible. Findings and Outcomes: An adjustable, modular socket design was trialled. The residual limb volume fluctuations were accommodated within the socket. Amputee rehabilitation could be continued, and the rehabilitation goals were achieved. The patient was able to wear the prosthesis for 8 h daily and to walk unaided indoors and outdoors. An adjustable, modular socket design accommodated the daily residual limb volume fluctuations and provided a successful outcome in this case. It demonstrates the complexities of socket fitting and design with volume fluctuations. Clinical relevance Ongoing complex regional pain syndrome symptoms within the residual limb can lead to fitting difficulties in a conventional, laminated thermoplastic socket due to volume fluctuations. An adjustable, modular socket design can accommodate this and provide a successful outcome.
Wang, Yao-zhong; Guan, Qun-li; Li, Ya-xin; Guo, Ji-lai; Jiang, Ling; Jia, Mu-yun; Deng, Yue
2013-02-01
To study the clinical effect of "gelatamp" colloidal silver gelatin sponge on preventing dry socket after extracting the mandibular impacted teeth. 1350 teeth extracted from 976 patients who needed to extract the mandibular impacted teeth were divided into group A, group B and group C randomly. "Gelatamp" colloidal silver gelatin sponge was implanted into alveolar socket after teeth extraction in group A, with absorbable gelatin sponge was implanted into alveolar socket in group B and nothing was implanted into alveolar socket in group C. The incidence of dry socket was observed, the data was analyzed using SPSS10.0 software package. The incidence of dry socket was 0.44% in group A, 2% in group B and 4.44% in group C. There was significant difference in the incidence of dry socket between group A and group C(P<0.01). There was also significant difference between group B and group C(P<0.05) and between group A and group B(P<0.05). The results demonstrate that "gelatamp" colloidal silver gelatin sponge can prevent the occurrence of dry socket after teeth extraction, which is of wide clinical use.
Coronal plane socket stability during gait in persons with transfemoral amputation: Pilot study.
Fatone, Stefania; Dillon, Michael; Stine, Rebecca; Tillges, Robert
2014-01-01
Little research describes which transfemoral socket design features are important for coronal plane stability, socket comfort, and gait. Our study objectives were to (1) relate socket comfort during gait to a rank order of changes in ischial containment (IC) and tissue loading and (2) compare socket comfort during gait when tissue loading and IC were systematically manipulated. Six randomly assigned socket conditions (IC and tissue compression) were assessed: (1) IC and high, (2) IC and medium, (3) IC and low, (4) no IC and high, (5) no IC and medium, and (6) no IC and low. For the six subjects in this study, there was a strong, negative relationship between comfort and changes in IC and tissue loading (rho = -0.89). With the ischium contained, tissue loading did not influence socket comfort (p = 0.47). With no IC, the socket was equally comfortable with high tissue loading (p = 0.36) but the medium (p = 0.04) and low (p = 0.02) tissue loading conditions decreased comfort significantly. Coronal plane hip moments, lateral trunk lean, step width, and walking speed were invariant to changes in IC and/or tissue loading. Our results suggest that in an IC socket, medial tissue loading mattered little in terms of comfort. Sockets without IC required high tissue loading to be as comfortable as those with IC, while suboptimal tissue loading compromised comfort.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stanislavskii, L.Ya.
Large turbogenerators with built-up rotor designs operating in U.S.S.R. power plants were studied to obtain data on reliability, failures, and performance characteristics for normal and abnormal operating conditions. Data for 23 turbogenerators manufactured by domestic and foreign firms were analyzed. The studies showed that the reliability factor of the joints of built-up rotors should be equal to approximately 6 to provide a monolithic built-up rotor. At lower built-up rotor joint reliability factors, weakening of the joints occurred during their operation, leading to extreme generator vibration, damage to the insulating sockets at the joint, burning of the joints and sometimes breakagemore » of the screws holding the joints. When it is necessary to restore the monolithic nature of the joints of a rotor its design should permit replacement of the tightening devices (tie rods, screws). If this is not possible the built-up rotor becomes unsuitable for operation. During abnormal conditions there are maximum temperatures in the joint of a built-up rotor about 50 percent greater than in the end part of the rotor. Thus special structural measures are necessary to improve the electrical contact in the joints of the built-up parts of the rotors of large turbogenerators. In all cases where they are not dictated by construction requirements (supercooled turbogenerators), the use of built-up rotors is unfavorable. (LCL)« less
Interventions for the prevention of dry socket: an evidence-based update.
Sharif, M O; Dawoud, B E S; Tsichlaki, A; Yates, J M
2014-07-11
This paper reviews the latest evidence for local and systemic interventions for the prevention of alveolar osteitis (dry socket). Dry socket is a painful and common post-operative complication following exodontia. Any interventions for the prevention of dry socket could reduce both its incidence and help avoid this painful complication. Prophylactic measures proposed in the literature are discussed. Furthermore, this article discusses both the clinical and histological stages of a normal healing socket.
Single-Rooted Extraction Sockets: Classification and Treatment Protocol.
El Chaar, Edgar; Oshman, Sarah; Fallah Abed, Pooria
2016-09-01
Clinicians have many treatment techniques from which to choose when extracting a failing tooth and replacing it with an implant-supported restoration and when successful management of an extraction socket during the course of tooth replacement is necessary to achieve predictable and esthetic outcomes. This article presents a straightforward, yet thorough, classification for extraction sockets of single-rooted teeth and provides guidance to clinicians in the selection of appropriate and predictable treatment. The presented classification of extraction sockets for single-rooted teeth focuses on the topography of the extraction socket, while the protocol for treatment of each socket type factors in the shape of the remaining bone, the biotype, and the location of the socket whether it be in the mandible or maxilla. This system is based on the biologic foundations of wound healing and can help guide clinicians to successful treatment outcomes.
Semi-flexible gas-insulated transmission line using protection tube in conductor plug-in joint
Kommineni, P.R.
1983-01-25
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. A plug and socket arrangement is utilized for joining adjacent sections of the inner conductor, and a protection tube is utilized inside the hollow plug to maintain proper alignment of the joint when the transmission line is bent. 3 figs.
Semi-flexible gas-insulated transmission line using protection tube in conductor plug-in joint
Kommineni, Prasad R.
1983-01-25
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. A plug and socket arrangement is utilized for joining adjacent sections of the inner conductor, and a protection tube is utilized inside the hollow plug to maintain proper alignment of the joint when the transmission line is bent.
An Amino Acid Code for Irregular and Mixed Protein Packing
Joo, Hyun; Chavan, Archana; Fraga, Keith; Tsai, Jerry
2015-01-01
To advance our understanding of protein tertiary structure, the development of the knob-socket model is completed in an analysis of the packing in irregular coil and turn secondary structure packing as well as between mixed secondary structure. The knob-socket model simplifies packing based on repeated patterns of 2 motifs: a 3 residue socket for packing within 2° structure and a 4 residue knob-socket for 3° packing. For coil and turn secondary structure, knob-sockets allow identification of a correlation between amino acid composition and tertiary arrangements in space. Coil contributes almost as much as α-helices to tertiary packing. Irregular secondary structure involves 3 residue cliques of consecutive contacting residues or XYZ sockets. In irregular sockets, Gly, Pro, Asp and Ser are favored, while Cys, His, Met and Trp are not. For irregular knobs, the preference order is Arg, Asp, Pro, Asn, Thr, Leu, and Gly, while Cys, His, Met and Trp are not. In mixed packing, the knob amino acid preferences are a function of the socket that they are packing into, whereas the amino acid composition of the sockets does not depend on the secondary structure of the knob. A unique motif of a coil knob with an XYZ β-sheet socket may potentially function to inhibit β-sheet extension. In addition, analysis of the preferred crossing angles for strands within a β-sheet and mixed α-helices/β-sheets identifies canonical packing patterns useful in protein design. Lastly, the knob-socket model abstracts the complexity of protein tertiary structure into an intuitive packing surface topology map. PMID:26370334
Sodium hyaluronate accelerates the healing process in tooth sockets of rats.
Mendes, Renato M; Silva, Gerluza A B; Lima, Miguel F; Calliari, Marcelo V; Almeida, Alvair P; Alves, José B; Ferreira, Anderson J
2008-12-01
In this study we evaluated the effects of sodium hyaluronate (HY) in the healing process of tooth sockets of rats. Immediately after the extraction of the upper first molars of male Holtzman rats, right sockets were treated with 1% HY gel (approximately 0.1 ml), while left sockets were used as control (blood clot). The animals were sacrificed at 2, 7, and 21 days after tooth extraction and upper maxillaries processed for histological and morphometric analysis of the apical and medium thirds of the sockets. Carbopol, an inert gel, was used to evaluate the mechanical effect of gel injection into sockets. Expression of bone morphogenetic protein-2 (BMP-2) and osteopontin (OPN) was determined by immunohistochemistry at 1, 2, 3, 4, 5, and 7 days after tooth extraction. Histological analysis showed that HY treatment induced earlier trabecular bone deposition resulting in a bone matrix more organized at 7 and 21 days after tooth extraction. Also, HY elicited significant increase in the amount of bone trabeculaes at 7 and 21 days after tooth extraction (percentage of trabecular bone area at 7 days: 13.21+/-4.66% vs. 2.58+/-1.36% in the apical third of control sockets) and in the vessels counting at 7 days. Conversely, the number of cell nuclei was decreased in HY-treated sockets. Additionally, expression of BMP-2 and OPN was enhanced in HY-treated sockets compared with control sockets. These findings suggest that HY accelerates the healing process in tooth sockets of rats stimulating the expression of osteogenic proteins.
Dry Socket: Frequency, Clinical Picture, and Risk Factors in a Palestinian Dental Teaching Center
Abu Younis, Mohammed H; Abu Hantash, Ra'ed O
2011-01-01
Aims: The objectives of this study were to find out the frequency, clinical picture, and risk factors of dry socket at the Dental Teaching Center of Al-Quds University in Palestine. Methods and Materials: Two previously used questionnaires were accomplished in this study over a one year period. The first questionnaire was completed for every patient who had one or more permanent teeth extracted in the Dental Surgery Clinic. The other one was completed for every patient suffered a postoperative pain and was diagnosed with dry socket. Results: There were 1305 dental extractions performed in 805 patients. The overall frequency of dry socket was 3.2%. The incidence of dry socket following non-surgical extractions was 1.7% while it was 15% following surgical extractions (P< 0.005). The incidence of dry socket was significantly higher in smokers (12%) than in non-smokers (4%) (P < 0.005), however, there is a strong association between the amount of smoking and the incidence of dry socket (P < 0.002). The incidence of dry socket was significantly higher in the single extraction cases (13%) than in the multiple extraction cases (5%) (P = 0.005). Age, sex, medical history, extraction site, amount of local anesthesia and experience of operator play no role in the occurrence of dry socket. Conclusion: Smoking, surgical trauma and single extractions are considered predisposing factors in the occurrence of dry socket. On the other hand, factors like: age, sex, medical history, extraction site, amount of anesthesia, and operator experience have no effect on the observation of dry socket. PMID:21559187
Modular socket system versus traditionally laminated socket: a cost analysis.
Normann, Elna; Olsson, Anna; Brodtkorb, Thor-Henrik
2011-03-01
Using the new modular socket system (MSS) to produce a prosthetic socket directly on the patient has the potential of being easier and quicker to manufacture but also incurring higher costs. The purpose of the study was to compare the costs of manufacturing a transtibial prosthetic socket using either a MSS or a standard laminated socket (PC). Concurrent controlled trial. A total of 20 patients at two orthopaedic facilities were followed with regards to the cost of manufacturing a prosthetic socket using either MSS or PC. Time aspects and material costs were considered in the cost analysis. Other factors studied include delivery time and number of visits. For the cost analysis, only direct costs pertaining to the prosthetic socket were considered. The total cost of MSS was found to be significantly higher (p < 0.01) compared to PC. However, the production and time cost was significantly lower. Delivery time to the patient was 1 day for MSS compared to 17 days for PC. Our study shows that the direct prosthetic cost of treating a patient using MSS is significantly higher than treating a patient using PC. However, the MSS prosthesis can be delivered significantly faster and with fewer visits. Further studies taking the full societal costs of MSS into account should therefore be performed. This study shows that the direct prosthetic cost of treating a patient with Modular Socket System is significantly higher than treating a patient with plastercasting with standard laminated socket. However, the Modular Socket System prosthesis can be delivered significantly faster and with fewer visits.
NASA Astrophysics Data System (ADS)
Nousiainen, O.; Putaala, J.; Kangasvieri, T.; Rautioaho, R.; Vähäkangas, J.
2007-03-01
The thermal fatigue endurance of completely lead-free 95.5Sn4Ag0.7Cu/plastic core solder ball (PCSB) composite joint structures in low-temperature Co-fired ceramic/printed wiring board (LTCC/PWB) assemblies was investigated using thermal cycling tests over the temperature ranges of -40°C 125°C and 0°C 100°C. Two separate creep/fatigue failures initiated and propagated in the joints during the tests: (1) a crack along the intermetallic compound (IMC)/solder interface on the LTCC side of the joint, which formed at the high-temperature extremes; and (2) a crack in the solder near the LTCC solder land, which formed at the low-temperature extremes. Moreover, localized recrystallization was detected at the outer edge of the joints that were tested in the harsh (-40°C 125°C) test conditions. The failure mechanism was creep/fatigue-induced mixed intergranular and transgranular cracking in the recrystallized zone, but it was dominated by transgranular thermal fatigue failure beyond the recrystallized zone. The change in the failure mechanism increased the rate of crack growth. When the lower temperature extreme was raised from -40°C to 0°C, no recrystallized zone was detected and the failure was due to intergranular cracks.
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
Metikala, Sreenivasulu; Mohammed, Riazuddin
2011-07-01
Extracting broken segments of intramedullay nails from long bones can be an operative challenge, particularly from the distal end. We report a case series where a simple and reproducible technique of extracting broken femoral cannulated nails using a ball-tipped guide wire is described. This closed technique involves no additional equipment or instruments. Eight patients who underwent the described method were included in the study. The technique involves using a standard plain guide wire passed through the cannulated distal broken nail segment after extraction of the proximal nail fragment. The plain guide wire is then advanced distally into the knee joint carefully under fluoroscopy imaging. Over this wire, a 5-millimeter (mm) cannulated large drill bit is used to create a track up to the distal broken nail segment. Through the small knee wound, a ball-tipped guide wire is passed, smooth end first, till the ball engages the end of the nail. The guide wire is then extracted along with the broken nail through the proximal wound. The method was successfully used in all eight patients for removal of broken cannulated intramedullary nail from the femoral canal without any complications. All patients underwent exchange nailing with successful bone union in six months. None of the patients had any problems at the knee joint at the final follow-up. We report a technique for successful extraction of the distal fragment of broken femoral intramedullary nails without additional surgical approaches.
Dutta, Shubha Ranjan; Singh, Purnima; Passi, Deepak; Patter, Pradeep
2015-09-01
To evaluate the efficacy of autologous platelet rich plasma (PRP) in regeneration of bone and to assess clinical compatibility of the material in mandibular third molar extraction socket. To compare the healing of mandibular third molar extraction wounds with and without PRP. Group A consists of the 30 patients where PRP will be placed in the extraction socket before closure of the socket. Group B consists of 30 patients who will be the control group where the extraction sockets will be closed without any intra socket medicaments. The patients would be allocated to the groups randomly. Soft tissue healing was better in study site compared to control site. The result of the study shows rapid bone regeneration in the extraction socket treated with PRP when compared with the socket without PRP. Evaluation for bone blending and trabecular bone formation started earlier in PRP site compared to control, non PRP site. Also there was less postoperative discomfort on the PRP treated side. Autologous PRP is biocompatible and has significant improved soft tissue healing, bone regeneration and increase in bone density in extraction sockets.
Clinical outcome and complications of thoracic and pelvic limb stump and socket prostheses.
Phillips, Andrew; Kulendra, Elvin; Bishop, Edith; Monk, Michelle; Parsons, Kevin; House, Arthur
2017-07-20
To describe the use, quality of life, compliance, complications, and outcome of animals fitted with stump socket prostheses. Medical records of dogs fitted with a stump socket prosthesis were reviewed. Functional outcome, quality of life and complications were retrospectively assessed from an owner questionnaire. Thirteen stump socket prostheses (12 dogs) were fitted for a variety of reasons including trauma, congenital abnormalities, and neoplasia. Eight dogs had a good outcome overall and four a poor outcome. Quality of life (QOL) remained good or excellent in 10/12 dogs. Nine complications were seen in 7/12 dogs, most were manageable; surgical wound complications (n = 2) and pressures sores (n = 4) were the most frequently encountered. One dog suffered multiple complications. Thoracic and pelvic limb stump socket prostheses had a similar complication rate, however all animals with a poor outcome had a thoracic limb stump socket prosthesis; two were small breed dogs (under 10 kg) and two had bilateral thoracic limb abnormalities. Stump socket prostheses are feasible and versatile in animals. In correctly selected cases, good to excellent outcomes are possible. However, complications are frequent but often manageable. Further investigations are required into the risk factors for poor outcomes and prospective studies are required to assess changes in biomechanics, function, and QOL before and after fitting of a stump socket prosthesis. Until further evidence is available, careful consideration should be given before fitting bilateral thoracic limb stump socket prostheses or thoracic limb stump socket prostheses to small breed dogs.
Boone, David A; Kobayashi, Toshiki; Chou, Teri G; Arabian, Adam K; Coleman, Kim L; Orendurff, Michael S; Zhang, Ming
2013-04-01
Alignment - the process and measured orientation of the prosthetic socket relative to the foot - is important for proper function of a transtibial prosthesis. Prosthetic alignment is performed by prosthetists using visual gait observation and amputees' feedback. The aim of this study was to investigate the effect of transtibial prosthesis malalignment on the moments measured at the base of the socket: the socket reaction moments. Eleven subjects with transtibial amputation were recruited from the community. An instrumented prosthesis alignment component was used to measure socket reaction moments during ambulation under 17 alignment conditions, including nominally aligned using conventional clinical methods, and angle perturbations of 3° and 6° (flexion, extension, abduction, and adduction) and translation perturbations of 5mm and 10mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. Coronal alignment perturbations caused systematic changes in the coronal socket reaction moments. All angle and translation perturbations revealed statistically significant differences on coronal socket reaction moments compared to the nominal alignment at 30% and 75% of stance phase (P<0.05). The effect of sagittal alignment perturbations on sagittal socket reaction moments was not as responsive as that of the coronal perturbations. The sagittal angle and translation perturbations of the socket led to statistically significant changes in minimum moment, maximum moment, and moments at 45% of stance phase in the sagittal plane. Therefore, malalignment affected the socket reaction moments in amputees with transtibial prostheses. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Mahin Shirazi, Sam
Accelerated thermal cycling (ATC) tests are the most commonly used tests for the thermo-mechanical performance assessment of microelectronics assemblies. Currently used reliability models have failed to incorporate the microstructural dependency of lead free solder joint behavior and its microstructure evolution during cycling. Thus, it is essential to have a mechanistic understanding of the effect of cycling parameters on damage evolution and failure of lead free solder joints in ATC. Recrystallization has been identified as the damage rate controlling mechanism in ATC. Usually it takes 1/3 of life for completion of recrystallization regardless of cycling parameters. Thus, the life of the solder joints can be predicted by estimating global recrystallization. The objective of the first part of the study was to examine whether the damage scenario applies in service is the same as the harsh thermal cycling tests (i.e. 0/100 °C and -40/125 °C) commonly used in industry. Microstructure analysis results on a variety of lead free solder SnAgCu assemblies subjected to the both harsh (0/100 °C) and mild (20/80 °C) ATC confirmed similar failure mechanism under the both testing conditions. Sn grain morphology (interlaced versus beach ball) has a significant effect on the thermo-mechanical performance (and thus the model) of the lead free solder joints. The longer thermal cycling lifetime observed in the interlaced solder joints subjected to the ATC compared to the beach ball structure was correlated to the different initial microstructure and the microstructure evolution during cycling. For the modeling proposes, the present study was focused on Sn-Ag-Cu solder joints with either a single Sn grain or beach ball structure. Microstructural analysis results of the simulated thermal cycling experiment revealed that, the life can be approximated as determined by the accumulation of a certain amount of work during the high temperature dwells. Finally the effect of precipitates spacing on acceleration factor was investigated. Results indicated that a smaller initial precipitate spacing would tend to result in a longer life in mild thermal cycling/service (where there is lower stresses). Accordingly, it is essential to incorporate the dependence of damage rate (i.e. recrystallization) on precipitate coarsening in any predictions.
Das, Swati; Jhingran, Rajesh; Bains, Vivek Kumar; Madan, Rohit; Srivastava, Ruchi; Rizvi, Iram
2016-01-01
Objectives: This study was primarily designed to determine the clinico-radiographic efficacy of platelet-rich fibrin (PRF) and beta-tri-calcium phosphate with collagen (β-TCP-Cl) in preserving extraction sockets. Materials and Methods: For Group I (PRF), residual sockets (n = 15) were filled with autologous PRF obtained from patients' blood; and for Group II (β-TCP-Cl), residual sockets (n = 15) were filled with β-TCP-Cl. For the sockets randomly selected for Group II (β-TCP-Cl), the reshaped Resorbable Tissue Replacement cone was inserted into the socket. Results: Clinically, there was a significantly greater decrease in relative socket depth, but apposition in midcrestal height in Group II (β-TCP-Cl) as compared to Group I (PRF), whereas more decrease in buccolingual width of Group I (PRF) than Group II (β-TCP-Cl) after 6 months. Radiographically, the mean difference in socket height, residual ridge, and width (coronal, middle, and apical third of socket) after 6 months was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). The mean density (in Hounsfield Units) at coronal, middle, and apical third of socket was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). There were statistically significant apposition and resorption for Group I (PRF) whereas nonsignificant resorption and significant apposition for Group II (β-TCP-Cl) in buccal and lingual/palatal cortical plate, respectively, at 6 months on computerized tomography scan. Conclusion: The use of either autologous PRF or β-TCP-Cl was effective in socket preservation. Results obtained from PRF were almost similar to β-TCP-Cl; therefore being autologous, nonimmune, cost-effective, easily procurable regenerative biomaterial, PRF proves to be an insight into the future biofuel for regeneration. PMID:27095909
Das, Swati; Jhingran, Rajesh; Bains, Vivek Kumar; Madan, Rohit; Srivastava, Ruchi; Rizvi, Iram
2016-01-01
This study was primarily designed to determine the clinico-radiographic efficacy of platelet-rich fibrin (PRF) and beta-tri-calcium phosphate with collagen (β-TCP-Cl) in preserving extraction sockets. For Group I (PRF), residual sockets (n = 15) were filled with autologous PRF obtained from patients' blood; and for Group II (β-TCP-Cl), residual sockets (n = 15) were filled with β-TCP-Cl. For the sockets randomly selected for Group II (β-TCP-Cl), the reshaped Resorbable Tissue Replacement cone was inserted into the socket. Clinically, there was a significantly greater decrease in relative socket depth, but apposition in midcrestal height in Group II (β-TCP-Cl) as compared to Group I (PRF), whereas more decrease in buccolingual width of Group I (PRF) than Group II (β-TCP-Cl) after 6 months. Radiographically, the mean difference in socket height, residual ridge, and width (coronal, middle, and apical third of socket) after 6 months was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). The mean density (in Hounsfield Units) at coronal, middle, and apical third of socket was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). There were statistically significant apposition and resorption for Group I (PRF) whereas nonsignificant resorption and significant apposition for Group II (β-TCP-Cl) in buccal and lingual/palatal cortical plate, respectively, at 6 months on computerized tomography scan. The use of either autologous PRF or β-TCP-Cl was effective in socket preservation. Results obtained from PRF were almost similar to β-TCP-Cl; therefore being autologous, nonimmune, cost-effective, easily procurable regenerative biomaterial, PRF proves to be an insight into the future biofuel for regeneration.
Quantification of rectifications for the Northwestern University Flexible Sub-Ischial Vacuum Socket.
Fatone, Stefania; Johnson, William Brett; Tran, Lilly; Tucker, Kerice; Mowrer, Christofer; Caldwell, Ryan
2017-06-01
The fit and function of a prosthetic socket depend on the prosthetist's ability to design the socket's shape to distribute load comfortably over the residual limb. We recently developed a sub-ischial socket for persons with transfemoral amputation: the Northwestern University Flexible Sub-Ischial Vacuum Socket. This study aimed to quantify the rectifications required to fit the Northwestern University Flexible Sub-Ischial Vacuum Socket to teach the technique to prosthetists as well as provide a computer-aided design-computer-aided manufacturing option. Development project. A program was used to align scans of unrectified and rectified negative molds and calculate shape change as a result of rectification. Averaged rectifications were used to create a socket template, which was shared with a central fabrication facility engaged in provision of Northwestern University Flexible Sub-Ischial Vacuum Sockets to early clinical adopters. Feedback regarding quality of fitting was obtained. Rectification maps created from 30 cast pairs of successfully fit Northwestern University Flexible Sub-Ischial Vacuum Sockets confirmed that material was primarily removed from the positive mold in the proximal-lateral and posterior regions. The template was used to fabricate check sockets for 15 persons with transfemoral amputation. Feedback suggested that the template provided a reasonable initial fit with only minor adjustments. Rectification maps and template were used to facilitate teaching and central fabrication of the Northwestern University Flexible Sub-Ischial Vacuum Socket. Minor issues with quality of initial fit achieved with the template may be due to inability to adjust the template to patient characteristics (e.g. tissue type, limb shape) and/or the degree to which it represented a fully mature version of the technique. Clinical relevance Rectification maps help communicate an important step in the fabrication of the Northwestern University Flexible Sub-Ischial Vacuum Socket facilitating dissemination of the technique, while the average template provides an alternative fabrication option via computer-aided design-computer-aided manufacturing and central fabrication.
Sewell, Philip; Noroozi, Siamak; Vinney, John; Amali, Ramin; Andrews, Stephen
2012-01-01
It has been recognised in a review of the developments of lower-limb prosthetic socket fitting processes that the future demands new tools to aid in socket fitting. This paper presents the results of research to design and clinically test an artificial intelligence approach, specifically inverse problem analysis, for the determination of the pressures at the limb/prosthetic socket interface during stance and ambulation. Inverse problem analysis is based on accurately calculating the external loads or boundary conditions that can generate a known amount of strain, stresses or displacements at pre-determined locations on a structure. In this study a backpropagation artificial neural network (ANN) is designed and validated to predict the interfacial pressures at the residual limb/socket interface from strain data collected from the socket surface. The subject of this investigation was a 45-year-old male unilateral trans-tibial (below-knee) traumatic amputee who had been using a prosthesis for 22 years. When comparing the ANN predicted interfacial pressure on 16 patches within the socket with actual pressures applied to the socket there is shown to be 8.7% difference, validating the methodology. Investigation of varying axial load through the subject's prosthesis, alignment of the subject's prosthesis, and pressure at the limb/socket interface during walking demonstrates that the validated ANN is able to give an accurate full-field study of the static and dynamic interfacial pressure distribution. To conclude, a methodology has been developed that enables a prosthetist to quantitatively analyse the distribution of pressures within the prosthetic socket in a clinical environment. This will aid in facilitating the "right first time" approach to socket fitting which will benefit both the patient in terms of comfort and the prosthetist, by reducing the time and associated costs of providing a high level of socket fit. Copyright © 2011 Elsevier B.V. All rights reserved.
An Amino Acid Packing Code for α-helical Structure and Protein Design
Joo, Hyun; Chavan, Archana G.; Phan, Jamie; Day, Ryan; Tsai, Jerry
2012-01-01
This work demonstrates that all packing in α-helices can be simplified to repetitive patterns of a single motif: the knob-socket. Using the precision of Voronoi Polyhedra/Deluaney Tessellations to identify contacts, the knob-socket is a 4 residue tetrahedral motif: a knob residue on one α-helix packs into the 3 residue socket on another α-helix. The principle of the knob-socket model relates the packing between levels of protein structure: the intra-helical packing arrangements within secondary structure that permit inter-helix tertiary packing interactions. Within an α-helix, the 3 residue sockets arrange residues into a uniform packing lattice. Inter-helix packing results from a definable pattern of interdigitated knob-socket motifs between 2 α-helices. Furthermore, the knob-socket model classifies 3 types of sockets: 1) free: favoring only intra-helical packing, 2) filled: favoring inter-helical interactions and 3) non: disfavoring α-helical structure. The amino acid propensities in these 3 socket classes essentially represent an amino acid code for structure in α-helical packing. Using this code, a novel yet straightforward approach for the design of α-helical structure was used to validate the knob-socket model. Unique sequences for 3 peptides were created to produce a predicted amount of α-helical structure: mostly helical, some helical, and no-helix. These 3 peptides were synthesized and helical content assessed using CD spectroscopy. The measured α-helicity of each peptide was consistent with the expected predictions. These results and analysis demonstrate that the knob-socket motif functions as the basic unit of packing and presents an intuitive tool to decipher the rules governing packing in protein structure. PMID:22426125
Improved Method Being Developed for Surface Enhancement of Metallic Materials
NASA Technical Reports Server (NTRS)
Gabb, Timothy P.; Telesman, Jack; Kantzos, Peter T.
2001-01-01
Surface enhancement methods induce a layer of beneficial residual compressive stress to improve the impact (FOD) resistance and fatigue life of metallic materials. A traditional method of surface enhancement often used is shot peening, in which small steel spheres are repeatedly impinged on metallic surfaces. Shot peening is inexpensive and widely used, but the plastic deformation of 20 to 40 percent imparted by the impacts can be harmful. This plastic deformation can damage the microstructure, severely limiting the ductility and durability of the material near the surface. It has also been shown to promote accelerated relaxation of the beneficial compressive residual stresses at elevated temperatures. Low-plasticity burnishing (LPB) is being developed as an improved method for the surface enhancement of metallic materials. LPB is being investigated as a rapid, inexpensive surface enhancement method under NASA Small Business Innovation Research contracts NAS3-98034 and NAS3-99116, with supporting characterization work at NASA. Previously, roller burnishing had been employed to refine surface finish. This concept was adopted and then optimized as a means of producing a layer of compressive stress of high magnitude and depth, with minimal plastic deformation (ref. 1). A simplified diagram of the developed process is given in the following figure. A single pass of a smooth, free-rolling spherical ball under a normal force deforms the surface of the material in tension, creating a compressive layer of residual stress. The ball is supported in a fluid with sufficient pressure to lift the ball off the surface of the retaining spherical socket. The ball is only in mechanical contact with the surface of the material being burnished and is free to roll on the surface. This apparatus is designed to be mounted in the conventional lathes and vertical mills currently used to machine parts. The process has been successfully applied to nickel-base superalloys by a team from the NASA Glenn Research Center, Lambda Research, and METCUT Research, as supported by the NASA Small Business Innovation Research Phase I and II programs, the Ultra Safe program, and the Ultra- Efficient Engine Technology (UEET) Program.
Iino, Yoichi; Kojima, Takeji
2016-01-01
The purpose of this study was to investigate the effect of the racket mass and the rate of strokes on the kinematics and kinetics of the trunk and the racket arm in the table tennis topspin backhand. Eight male Division I collegiate table tennis players hit topspin backhands against topspin balls projected at 75 balls · min(-1) and 35 balls · min(-1) using three rackets varying in mass of 153.5, 176 and 201.5 g. A motion capture system was used to obtain trunk and racket arm motion data. The joint torques of the racket arm were determined using inverse dynamics. The racket mass did not significantly affect all the trunk and racket arm kinematics and kinetics examined except for the wrist dorsiflexion torque, which was significantly larger for the large mass racket than for the small mass racket. The racket speed at impact was significantly lower for the high ball frequency than for the low ball frequency. This was probably because pelvis and upper trunk axial rotations tended to be more restricted for the high ball frequency. The result highlights one of the advantages of playing close to the table and making the rally speed fast.
Factors affecting the stability of reverse shoulder arthroplasty: a biomechanical study.
Clouthier, Allison L; Hetzler, Markus A; Fedorak, Graham; Bryant, J Tim; Deluzio, Kevin J; Bicknell, Ryan T
2013-04-01
Despite the success of reverse shoulder arthroplasty (RSA) in treating patients with painful pseudoparalytic shoulders, instability is a common complication and currently the factors affecting stability are not well understood. The objective of this study was to investigate a number of factors as well as the interactions between factors to determine how they affect the stability of the prosthesis. These factors included: active arm posture (abduction and abduction plane angles), loading direction, glenosphere diameter and eccentricity, and humeral socket constraint. Force required to dislocate the joint, determined using a biomechanical shoulder simulator, was used as a measure of stability. A factorial design experiment was implemented to examine the factors and interactions. Actively increasing the abduction angle by 15° leads to a 30% increase in stability and use of an inferior-offset rather than a centered glenosphere improved stability by 17%. Use of a more constrained humeral socket also increased stability; but the effect was dependent on loading direction, with a 88% improvement for superior loading, 66% for posterior, 36% for anterior, and no change for inferior loading. Abduction plane angle and glenosphere diameter had no effect on stability. Increased glenohumeral abduction and the use of an inferior-offset glenosphere were found to increase the stability of RSA. Additionally, use of a more constrained humeral socket increased stability for anterior, posterior, and superior loading. These identified factor effects have the potential to decrease the risk of dislocation following RSA. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Cerebellar subjects show impaired adaptation of anticipatory EMG during catching.
Lang, C E; Bastian, A J
1999-11-01
We evaluated the role of the cerebellum in adapting anticipatory muscle activity during a multijointed catching task. Individuals with and without cerebellar damage caught a series of balls of different weights dropped from above. In Experiment 1 (light-heavy-light), each subject was required to catch light balls (baseline phase), heavy balls (adaptation phase), and then light balls again (postadaptation phase). Subjects were not told when the balls would be switched, and they were required to keep their hand within a vertical spatial "window" during the catch. During the series of trials, we measured three-dimensional (3-D) position and electromyogram (EMG) from the catching arm. We modeled the adaptation process using an exponential decay function; this model allowed us to dissociate adaptation from performance variability. Results from the position data show that cerebellar subjects did not adapt or adapted very slowly to the changed ball weight when compared with the control subjects. The cerebellar group required an average of 30.9 +/- 8.7 trials (mean +/- SE) to progress approximately two-thirds of the way through the adaptation compared with 1.7 +/- 0.2 trials for the control group. Only control subjects showed a negative aftereffect indicating storage of the adaptation. No difference in performance variability existed between the two groups. EMG data show that control subjects increased their anticipatory muscle activity in the flexor muscles of the arm to control the momentum of the ball at impact. Cerebellar subjects were unable to differentially increase the anticipatory muscle activity across three joints to perform the task successfully. In Experiment 2 (heavy-light-heavy), we tested to see whether the rate of adaptation changed when adapting to a light ball versus a heavy ball. Subjects caught the heavy balls (baseline phase), the light balls (adaptation phase), and then heavy balls again (postadaptation phase). Comparison of rates of adaptation between Experiment 1 and Experiment 2 showed that the rate of adaptation was unchanged whether adapting to a light ball or a heavy ball. Given these findings, we conclude that the cerebellum is important in generating the appropriate anticipatory muscle activity across multiple muscles and modifying it in response to changing demands though trial-and-error practice.
Socket welds in nuclear facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, P.A.; Torres, L.L.
1995-12-31
Socket welds are easier and faster to make than are butt welds. However, they are often not used in nuclear facilities because the crevices between the pipes and the socket sleeves may be subject to crevice corrosion. If socket welds can be qualified for wider use in facilities that process nuclear materials, the radiation exposures to welders can be significantly reduced. The current tests at the Idaho Chemical Processing Plant (ICPP) are designed to determine if socket welds can be qualified for use in the waste processing system at a nuclear fuel processing plant.
Kobayashi, Toshiki; Orendurff, Michael S; Boone, David A
2013-09-27
The alignment of a lower-limb prosthesis is critical to the successful prosthetic fitting and utilization by the wearer. Loads generated by the socket applied to the residual limb while walking are thought to be different in transfemoral and knee-disarticulation prostheses. The aim of this case series was to compare the socket reaction moments between transfemoral and knee-disarticulation prostheses and to investigate the effect of alignment changes on them. Two amputees, one with a transfemoral prosthesis and another with a knee-disarticulation prosthesis, participated in this study. A Smart Pyramid™ was used to measure socket reaction moments while walking under 9 selected alignment conditions; including nominally aligned, angle malalignments of 6° (flexion, extension, abduction and adduction) and translation malalignments of 15 mm (anterior, posterior, medial and lateral) of the socket relative to the foot. This study found that the pattern of the socket reaction moments was similar between transfemoral and knee-disarticulation prostheses. An extension moment in the sagittal plane and a varus moment in the coronal plane were dominant during stance under the nominally aligned condition. This study also demonstrated that alignment changes might have consistent effects on the socket reaction moments in transfemoral and knee-disarticulation prostheses. Extension and posterior translation of the socket resulted in increases in an extension moment, while abduction and lateral translation of the socket resulted in increases in a varus moment. The socket reaction moments may potentially serve as useful biomechanical parameters to evaluate alignment in transfemoral and knee-disarticulation prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
Leong, R.
1993-06-22
The invention is a receptacle for a three prong electrical plug which has either a tubular or U-shaped grounding prong. The inventive receptacle has a grounding prong socket which is sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having two ridges to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. The two ridges are made to prevent the socket from expanding when either the U-shaped grounding prong or the tubular grounding prong is inserted.
Leong, Robert
1993-01-01
The invention is a receptacle for a three prong electrical plug which has either a tubular or U-shaped grounding prong. The inventive receptacle has a grounding prong socket which is sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having two ridges to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. The two ridges are made to prevent the socket from expanding when either the U-shaped grounding prong or the tubular grounding prong is inserted.
Haraji, Afshin; Rakhshan, Vahid; Khamverdi, Naiemeh; Alishahi, Hadiseh Khanzadeh
2013-01-01
To assess the effects of intra-alveolar application of chlorhexidine gel on the incidence of alveolar osteitis (dry socket) and the severity of postsurgical pain. A total of 160 impacted mandibular third molars were extracted in 80 patients enrolled in this trial. In each subject, a socket was randomly selected and packed to the crest of the alveolar ridge with a gelatin sponge dressing saturated in 0.2% chlorhexidine gel. The contralateral socket was packed with a dry dressing as the placebo. None of the included patients took antibiotics or analgesics. The occurrence of dry socket and patients' pain levels were assessed at the first and third postoperative days. The data were analyzed using Spearman correlation coefficient, McNemar, Wilcoxon, and chi-square tests. Chlorhexidine gel significantly reduced dry socket incidence from 32.6% to 11.3% (P ≤ .001 [McNemar and chi-square], absolute risk reduction = 21.2%, relative risk reduction = 65.4%, odds ratio = 0.263, relative risk = 0.345). It also significantly relieved postoperative pain on both sides in all the patients (P ≤ .001 [Wilcoxon]) and also in the 54 subjects who did not develop dry socket (P ≤ .001 [Wilcoxon]). Besides decreasing the incidence of dry socket, chlorhexidine gel can reduce postsurgical pain in patients with and without dry socket.
Schwesig, René; Hermassi, Souhail; Wagner, Herbert; Fischer, David; Fieseler, Georg; Molitor, Thomas; Delank, Karl-Stefan
2016-12-01
Schwesig, R, Hermassi, S, Wagner, H, Fischer, D, Fieseler, G, Molitor, T, and Delank, K-S. Relationship between the range of motion and isometric strength of elbow and shoulder joints and ball velocity in women team handball players. J Strength Cond Res 30(12): 3428-3435, 2016-The aims of this study were to investigate relationships between isometric strength and range of motion (ROM) of shoulder and elbow joints and compare 2 different team handball throwing techniques in women team handball. Twenty highly experienced women team handball players (age: 20.7 ± 2.9 years; body mass: 68.4 ± 6.0 kg; and height: 1.74 ± 0.06 m) participated in this study. The isometric strength (hand-held dynamometer) and ROM (goniometer) of shoulder and elbow joints were measured at the beginning of the preseasonal training. After clinical examination, the subjects performed 3 standing throws with run-up (10 m) and 3 jump throws over a hurdle (0.20 m). The mean ball velocity was calculated from 3 attempts and measured using a radar gun. The results showed that the ball velocity of the standing throw with run-up (vST) was significantly higher than that of the jump throw (vJT) (25.5 ± 1.56 vs. 23.2 ± 1.31 m·s; p < 0.001). Therefore, significant playing position effects (p = 0.021) were only found for ST. Goalkeepers (n = 2) had the lowest (22.6 ± 0.04 m·s) and backcourt players (n = 9), the highest (26.1 ± 1.36 m·s) vST. The retroversion strength in the shoulder was the only parameter with relevant correlations to both throws (vST: r = 0.52, and vJT: r = 0.43). Other relevant relationships to vJT were found for adduction strength shoulder (r = 0.55) and ROM flexion elbow (r = -0.54). The vST was only correlated to the glenohumeral internal rotation deficit. As a consequence, strength is more important than the ROM, and in addition to this, the shoulder, compared with the elbow, has a greater influence on the vST in highly experienced women team handball players.
Characterization of interfacial socket pressure in transhumeral prostheses: A case series.
Schofield, Jonathon S; Schoepp, Katherine R; Williams, Heather E; Carey, Jason P; Marasco, Paul D; Hebert, Jacqueline S
2017-01-01
One of the most important factors in successful upper limb prostheses is the socket design. Sockets must be individually fabricated to arrive at a geometry that suits the user's morphology and appropriately distributes the pressures associated with prosthetic use across the residual limb. In higher levels of amputation, such as transhumeral, this challenge is amplified as prosthetic weight and the physical demands placed on the residual limb are heightened. Yet, in the upper limb, socket fabrication is largely driven by heuristic practices. An analytical understanding of the interactions between the socket and residual limb is absent in literature. This work describes techniques, adapted from lower limb prosthetic research, to empirically characterize the pressure distribution occurring between the residual limb and well-fit transhumeral prosthetic sockets. A case series analyzing the result of four participants with transhumeral amputation is presented. A Tekscan VersaTek pressure measurement system and FaroArm Edge coordinate measurement machine were employed to capture socket-residual limb interface pressures and geometrically register these values to the anatomy of participants. Participants performed two static poses with their prosthesis under two separate loading conditions. Surface pressure maps were constructed from the data, highlighting pressure distribution patterns, anatomical locations bearing maximum pressure, and the relative pressure magnitudes. Pressure distribution patterns demonstrated unique characteristics across the four participants that could be traced to individual socket design considerations. This work presents a technique that implements commercially available tools to quantitatively characterize upper limb socket-residual limb interactions. This is a fundamental first step toward improved socket designs developed through informed, analytically-based design tools.
Characterization of interfacial socket pressure in transhumeral prostheses: A case series
Schoepp, Katherine R.; Williams, Heather E.; Carey, Jason P.; Marasco, Paul D.
2017-01-01
One of the most important factors in successful upper limb prostheses is the socket design. Sockets must be individually fabricated to arrive at a geometry that suits the user’s morphology and appropriately distributes the pressures associated with prosthetic use across the residual limb. In higher levels of amputation, such as transhumeral, this challenge is amplified as prosthetic weight and the physical demands placed on the residual limb are heightened. Yet, in the upper limb, socket fabrication is largely driven by heuristic practices. An analytical understanding of the interactions between the socket and residual limb is absent in literature. This work describes techniques, adapted from lower limb prosthetic research, to empirically characterize the pressure distribution occurring between the residual limb and well-fit transhumeral prosthetic sockets. A case series analyzing the result of four participants with transhumeral amputation is presented. A Tekscan VersaTek pressure measurement system and FaroArm Edge coordinate measurement machine were employed to capture socket-residual limb interface pressures and geometrically register these values to the anatomy of participants. Participants performed two static poses with their prosthesis under two separate loading conditions. Surface pressure maps were constructed from the data, highlighting pressure distribution patterns, anatomical locations bearing maximum pressure, and the relative pressure magnitudes. Pressure distribution patterns demonstrated unique characteristics across the four participants that could be traced to individual socket design considerations. This work presents a technique that implements commercially available tools to quantitatively characterize upper limb socket-residual limb interactions. This is a fundamental first step toward improved socket designs developed through informed, analytically-based design tools. PMID:28575012
A smartphone photogrammetry method for digitizing prosthetic socket interiors.
Hernandez, Amaia; Lemaire, Edward
2017-04-01
Prosthetic CAD/CAM systems require accurate 3D limb models; however, difficulties arise when working from the person's socket since current 3D scanners have difficulties scanning socket interiors. While dedicated scanners exist, they are expensive and the cost may be prohibitive for a limited number of scans per year. A low-cost and accessible photogrammetry method for socket interior digitization is proposed, using a smartphone camera and cloud-based photogrammetry services. 15 two-dimensional images of the socket's interior are captured using a smartphone camera. A 3D model is generated using cloud-based software. Linear measurements were comparing between sockets and the related 3D models. 3D reconstruction accuracy averaged 2.6 ± 2.0 mm and 0.086 ± 0.078 L, which was less accurate than models obtained by high quality 3D scanners. However, this method would provide a viable 3D digital socket reproduction that is accessible and low-cost, after processing in prosthetic CAD software. Clinical relevance The described method provides a low-cost and accessible means to digitize a socket interior for use in prosthetic CAD/CAM systems, employing a smartphone camera and cloud-based photogrammetry software.
Robot friendly probe and socket assembly
NASA Technical Reports Server (NTRS)
Nyberg, Karen L. (Inventor)
1994-01-01
A probe and socket assembly for serving as a mechanical interface between structures is presented. The assembly comprises a socket having a housing adapted for connection to a first supporting structure and a probe which is readily connectable to a second structure and is designed to be easily grappled and manipulated by a robotic device for insertion and coupling with the socket. Cooperable automatic locking means are provided on the probe shaft and socket housing for automatically locking the probe in the socket when the probe is inserted a predetermined distance. A second cooperable locking means on the probe shaft and housing are adapted for actuation after the probe has been inserted the predetermined distance. Actuation means mounted on the probe and responsive to the grip of the probe handle by a gripping device, such as a robot for conditioning the probe for insertion and are also responsive to release of the grip of the probe handle to actuate the second locking means to provide a hard lock of the probe in the socket.
Jambhekar, Shantanu; Kernen, Florian; Bidra, Avinash S
2015-05-01
Several biomaterials and techniques have been reported for socket grafting and alveolar ridge preservation. However, the evidence for clinical and histologic outcomes for socket grafting with different types of materials in flapless extraction is not clear. The purpose of this systematic review was to analyze the outcomes of a socket grafting procedure performed with flapless extraction of teeth in order to determine which graft material results in the least loss of socket dimensions, the maximum amount of vital bone, the least remnant graft material, and the least amount of connective tissue after a minimum of 12 weeks of healing. Secondary outcomes, including the predictability of regenerating deficient buccal bone, necessity of barrier membranes, and coverage with autogenous soft tissue graft, were also evaluated. An electronic search for articles in the English-language literature was performed independently by multiple investigators using a systematic search process with the PubMed search engine. After applying predetermined inclusion and exclusion criteria, the final list of randomized controlled clinical trials (RCTs) for flapless extraction and socket grafting was analyzed to derive results for the various objectives of the study. The initial electronic search resulted in 2898 titles. The systematic application of inclusion and exclusion criteria resulted in 32 RCTs studying 1354 sockets, which addressed the clinical and histologic outcomes of flapless extraction with socket grafting and provided dimensional and histologic information at or beyond the 12-week reentry period. From these RCTs, the mean loss of buccolingual width at the ridge crest was lowest for xenografts (1.3 mm), followed by allografts (1.63 mm), alloplasts (2.13 mm), and sockets without any socket grafting (2.79 mm). Only 3 studies reported on loss of width at 3 mm below the ridge crest. The mean loss of buccal wall height from the ridge crest was lowest for xenografts (0.57 mm) and allografts (0.58 mm), followed by alloplasts (0.77 mm) and sockets without any grafting (1.74 mm). The mean histologic outcomes at or beyond the 12-week reentry period revealed the highest vital bone content for sockets grafted with alloplasts (45.53%), followed by sockets with no graft material (41.07%), xenografts (35.72%), and allografts (29.93%). The amount of remnant graft material was highest for sockets grafted with allografts (21.75%), followed by xenografts (19.3%) and alloplasts (13.67%). The highest connective tissue content at the time of reentry was seen for sockets with no grafting (52.53%), followed by allografts (51.03%), xenografts (44.42%), and alloplast (38.39%). Data for new and emerging biomaterials such as cell therapy and tissue regenerative materials were not amenable to calculations because of biomaterial heterogeneity and small sample sizes. After flapless extraction of teeth, and using a minimum healing period of 12 weeks as a temporal measure, xenografts and allografts resulted in the least loss of socket dimensions compared to alloplasts or sockets with no grafting. Histologic outcomes after a minimum of 12 weeks of healing showed that sockets grafted with alloplasts had the maximum amount of vital bone and the least amount of remnant graft material and remnant connective tissue. There is a limited but emerging body of evidence for the predictable regeneration of deficient buccal bone with socket grafting materials, need for barrier membranes, use of tissue engineering, and use of autogenous soft tissue grafts from the palate to cover the socket. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Fatigue evaluation of socket welded piping in nuclear power plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vecchio, R.S.
1996-12-01
Fatigue failures in piping systems occur, almost without exception, at the welded connections. In nuclear power plant systems, such failures occur predominantly at the socket welds of small diameter piping ad fillet attachment welds under high-cycle vibratory conditions. Nearly all socket weld fatigue failures are identified by leaks which, though not high in volume, generally are costly due to attendant radiological contamination. Such fatigue cracking was recently identified in the 3/4 in. diameter recirculation and relief piping socket welds from the reactor coolant system (RCS) charging pumps at a nuclear power plant. Consequently, a fatigue evaluation was performed to determinemore » the cause of cracking and provide an acceptable repair. Socket weld fatigue life was evaluated using S-N type fatigue life curves for welded structures developed by AASHTO and the assessment of an effective cyclic stress range adjacent to each socket weld. Based on the calculated effective tress ranges and assignment of the socket weld details to the appropriate AASHTO S-N curves, the socket weld fatigue lives were calculated and found to be in excellent agreement with the accumulated cyclic life to-date.« less
Computer design synthesis of a below knee-Syme prosthesis
NASA Technical Reports Server (NTRS)
Elangovan, P. T.; Ghista, D. N.; Alwar, R. S.
1979-01-01
A detailed design synthesis analysis of the BK Syme prosthesis is provided, to determine the socket's cutout orientation size and shape, cutout fillet shape, socket wall thickness distribution and the reinforced fiber distribution in the socket wall, for a minimally stressed structurally safe lightweight prosthesis. For analysis purposes, the most adverse socket loading is obtained at the push-off stage of gait; this loading is idealized as an axial in-plane loading on the bottom edge of the circular cylindrical socket shell whose top edge is considered fixed. Finite element stress analysis of the socket shell (with uniform and graded wall thickness) are performed for various orientations of the cutout and for various types of corner fillets. A lateral cutout with a streamline fillet is recommended. The wall material (i.e., thickness) distribution is determined so as to minimize the stresses, while ensuring that the wall material's stress limits are not exceeded. For such a maximally stressed lightweight socket shell, the panels in the neighborhood of the cutout are checked to ensure that they do not buckle under their acquired stresses. A fiber-reinforced laminated composite socket shell is also analyzed in order to recommend optimum variables in orientations and densities of reinforcing fibers.
Ahn, Jae-Jin; Shin, Hong-In
2008-01-01
To investigate postextraction bone formation over time in both diseased and healthy sockets. Core specimens of healing tissues following tooth extraction were obtained at the time of implant placement in patients treated between October 2005 and December 2007. A disease group and a control group were classified according to socket examination at the time of extraction. The biopsy specimens were analyzed histomorphometrically to measure the dimensional changes among 3 tissue types: epithelial layer, connective tissue area, and new bone tissue area. Fifty-five specimens from sites of previously advanced periodontal disease from 45 patients were included in the disease group. Another 12 specimens of previously healthy extraction sockets were collected from 12 different patients as a control. The postextraction period of the disease group varied from 2 to 42 weeks. In the disease group, connective tissue occupied most of the socket during the first 4 weeks. New bone area progressively replaced the connective tissue area after the first 4 weeks. The area proportion of new bone tissue exceeded that of connective tissue by 14 weeks. After 20 weeks, most extraction sockets in the disease group demonstrated continuous new bone formation. The control group exhibited almost complete socket healing after 10 weeks, with no more new bone formation after 20 weeks. Osseous regeneration in the diseased sockets developed more slowly than in the disease-free sockets. After 16 weeks, new bone area exceeded 50% of the total newly regenerated tissue in the sockets with severe periodontal destruction. In the control group, after 8 weeks, new bone area exceeded 50% of the total tissue.
Socket stars: UBVRJIK radial profiles
NASA Astrophysics Data System (ADS)
Schaefer, Bradley E.
1995-05-01
Visual inspectin of stars embedded in H II nebulae has shown a significant fraction to be surrounded by nearly symmetric extended regions within which the nebular brightness is apparently significantly fainter than is typical for the surrounding area. These 'socket stars' might be caused by a bubble in the nebula blown out by a stellar wind or they might be caused by a circumstellar envelope of dust hiding the emission behind the star. As such, the sockets could be the first manifestation of a previously unknown component of pre-main-sequence stars. Unfortunately, no quantitative proof of the existence of sockets has been presented. To fill this need, I have imaged 10 socket stars and six background stars with CCD cameras and infrared array cameras. From these images, I have constructed radial plots which should reveal dips in brightness immediately outside the seeing disk. The radial plots do not show any evidence for the existence of sockets. A detailed examination of the photographs orginally used to identify the sockets show that the causes of these reports are (1) artifacts resulting from the photographic process of dodging and (2) random coincidence of stars with local minima in nebular brightness. Thus, I conclude that 'socket stars' do not exist.
Coordination and variability in the elite female tennis serve.
Whiteside, David; Elliott, Bruce Clifford; Lay, Brendan; Reid, Machar
2015-01-01
Enhancing the understanding of coordination and variability in the tennis serve may be of interest to coaches as they work with players to improve performance. The current study examined coordinated joint rotations and variability in the lower limbs, trunk, serving arm and ball location in the elite female tennis serve. Pre-pubescent, pubescent and adult players performed maximal effort flat serves while a 22-camera 500 Hz motion analysis system captured three-dimensional body kinematics. Coordinated joint rotations in the lower limbs and trunk appeared most consistent at the time players left the ground, suggesting that they coordinate the proximal elements of the kinematic chain to ensure that they leave the ground at a consistent time, in a consistent posture. Variability in the two degrees of freedom at the elbow became significantly greater closer to impact in adults, possibly illustrating the mechanical adjustments (compensation) these players employed to manage the changing impact location from serve to serve. Despite the variable ball toss, the temporal composition of the serve was highly consistent and supports previous assertions that players use the location of the ball to regulate their movement. Future work should consider these associations in other populations, while coaches may use the current findings to improve female serve performance.
Fee, L
2017-04-21
Socket preservation maintains bone volume post-extraction in anticipation of an implant placement or fixed partial denture pontic site. This procedure helps compensate for the resorption of the facial bone wall. Socket preservation should be considered when implant placement needs to be delayed for patient or site-related reasons. The ideal healing time before implant placement is six months. Socket preservation can reduce the need for later bone augmentation. By reducing bone resorption and accelerating bone formation it increases implant success and survival. Biomaterials for socket grafting including autograft, allograft, xenograft and alloplast. A bone substitute with a low substitution rate is recommended.
Physical Modeling of Shear Behavior of Infilled Rock Joints Under CNL and CNS Boundary Conditions
NASA Astrophysics Data System (ADS)
Shrivastava, Amit Kumar; Rao, K. Seshagiri
2018-01-01
Despite their frequent natural occurrence, filled discontinuities under constant normal stiffness (CNS) boundary conditions have been studied much less systematically, perhaps because of the difficulties arising from the increased number of variable parameters. Because of the lack of reliable and realistic theoretical or empirical relations and the difficulties in obtaining and testing representative samples, engineers rely on judgment and often consider the shear strength of the infilled material itself as shear strength of rock joints. This assumption leads to uneconomical and also sometimes the unsafe design of underground structures, slopes, rock-socketed piles and foundations. To study the effect of infill on the shear behavior of rock joints, tests were performed on the modeled infilled rock joint having different joint roughness under constant normal load (CNL) and CNS boundary conditions at various initial normal stress and varying thickness of the infilled material. The test results indicate that shear strength decreases with an increase in t/ a ratio for both CNL and CNS conditions, but the reduction in shear strength is more for CNL than for CNS condition for a given initial normal stress. The detailed account of the effect of thickness of infilled material on shear and deformation behavior of infilled rock joint is discussed in this paper, and a model is proposed to predict shear strength of infilled rock joint.
Tethering sockets and wrenches
NASA Technical Reports Server (NTRS)
Johnson, E. P.
1990-01-01
The tethering of sockets and wrenches was accomplished to improve the safety of working over motor segments. To accomplish the tethering of the sockets to the ratchets, a special design was implemented in which a groove was machined into each socket. Each socket was then fitted with a snap ring that can spin around the machined groove. The snap ring is tethered to the handle of the ratchet. All open end wrenches are also tethered to the ratchet or to the operator, depending upon the type. Tests were run to ensure that the modified tools meet torque requirements. The design was subsequently approved by Space Safety.
An evaluation of end-point trajectory planning during skilled kicking.
Ford, Paul; Hodges, Nicola J; Mark Williams, A
2009-01-01
There is evidence that actions are planned by anticipation of their external effects, with the strength of this effect being dependent on the amount of prior practice. In Experiment 1, skilled soccer players performed a kicking task under four conditions: planning in terms of an external action effect (i.e., ball trajectory) or in terms of body movements, either with or without visual error feedback. When feedback was withheld, a ball focus resulted in more accurate outcomes than a body focus. When visual feedback was allowed, there was no difference between these two conditions. In Experiment 2, both skilled and novice soccer players were tested with the addition of a control condition and in the absence of visual feedback. For both groups there was evidence that a ball focus was more beneficial for performance than a body focus, particularly in terms of movement kinematics where correlations across the joints were generally higher for body rather than ball planning. Most skilled participants reported that ball planning felt more normal than body planning. These experiments provide some evidence that actions are planned in terms of their external action effects, supporting the common-coding hypothesis of action planning.
Girish Kumar, N; Chaudhary, Rupanzal; Kumar, Ish; Arora, Srimathy S; Kumar, Nilesh; Singh, Hem
2018-06-01
The purpose of this study is to evaluate the efficacy of Platelet Rich Fibrin (PRF) as a socket plug with or without use of Plaster of Paris (POP) as bone substitute to preserve the alveolar ridge post-extraction. A prospective randomised single blind controlled study, was conducted for 18 months from November 2014 to May 2016 on 48 patients requiring extraction. All teeth were extracted atraumatically using periotomes and luxators without raising mucoperiosteal flap. Sockets were randomly allotted to groups A, B and C. Group A sockets were chosen as control, where figure of eight suture was placed. In group B sockets, PRF obtained by centrifugation was used as a socket plug and stabilised with figure of eight suture. Group C sockets were filled with POP and then covered with PRF. The socket was then closed with a figure of eight suture. Patients were informed of need for 6 months follow-up. Ninety sockets in 48 patients were subjected to our study. We found that results in the sockets where we have grafted POP showed better ridge preservation and post-operative comfort even though the difference in ridge resorption between the three groups was not statistically significant. Powered by Editorial Manager® and ProduXion Manager® from the Aries Systems Corporation. Atraumatic extraction may minimise the post-operative pain and discomfort to patient as well as the post-extraction alveolar height and width changes. The use of PRF and/or bone substitute even though clinically contributes to better post-operative healing and minimal loss of alveolar width and height, the values were not statistically significant.
Timeframe of socket cortication after tooth extraction: A retrospective radiographic study.
Bertl, Kristina; Kukla, Edmund Benjamin; Albugami, Rajaa; Beck, Florian; Gahleitner, André; Stavropoulos, Andreas
2018-01-01
To assess the timeframe between tooth extraction and radiographically detectable socket cortication in humans. Two hundred and fifty patients with a CT scan ≤36 months after tooth extraction were included. First, three orthoradial multiplanar reconstruction slices, representing the major part of the extraction socket, were scored regarding the degree of bone healing as (i) healed, that is, complete/continuous cortication of the socket entrance, or (ii) non-healed. Thereafter, based on the results of all three slices, the stage of cortication of the extraction socket, as one unit, was classified as (i) non-corticated, that is, all three slices judged as non-healed, (ii) partially corticated, that is, 1 or 2 slices judged as non-healed, or (iii) completely corticated, that is, all three slices judged as healed. The possible effect of several independent parameters, that is, age, gender, timeframe between tooth extraction and CT scan, tooth type, extent of radiographic bone loss of the extracted tooth, tooth-gap type, smoking status, presence of any systemic disease, and medication intake, on cortication status was statistically evaluated. Three to 6 months after tooth extraction, 27% of the sockets were judged as non-corticated and 53% were judged as partially corticated. After 9-12 months, >80% of the sockets were corticated, while some incompletely corticated sockets were detected up to 15 months after extraction. Each additional month after tooth extraction contributed significantly to a higher likelihood of a more advanced stage of cortication, while radiographic bone loss ≥75% significantly prolonged cortication time; no other independent variable had a significant effect. The results indicate a considerably long timeframe until complete cortication of an extraction socket, that is, 3-6 months after tooth extraction 3 of 4 sockets were still not completely corticated, and only after 9-12 months, complete cortication was observed in about 80% of the sockets. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.
Zhang, Linlin; Zhu, Ming; Shen, Ling; Zheng, Feng
2013-01-01
Transfemoral amputees need prosthetic devices after amputation surgery, and the interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. The purpose of this study was to build a nonlinear finite element model to investigate the interface pressure between the above-knee residual limb and its prosthetic socket. The model was three-dimensional (3D) with consideration of nonlinear boundary conditions. Contact analysis was used to simulate the friction conditions between skin and the socket. The normal stresses up to 80.57 kPa at the distal end of the soft tissue. The longitudinal and circumferential shear stress distributions at the limb-socket interface were also simulated. This study explores the influences of load transfer between trans-femoral residual limb and its prosthetic socket.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-15
... with medium screw base sockets, as well as pin-based sockets. (42 U.S.C. 6295(ff)(2)-(3)) The statute... (including candelabra screw base sockets) by January 1, 2007, and if DOE failed to issue such standards by... standards for light kits with sockets other than medium-screw base or pin-based fluorescent lamps in the CFR...
Fickl, Stefan; Zuhr, Otto; Wachtel, Hannes; Kebschull, Moritz; Hürzeler, Markus B
2009-10-01
The aim of this study was to histometrically assess alterations of the ridge following socket preservation alone and socket preservation with additional buccal overbuilding. In five beagle dogs four extraction sites were randomly subjected to one of the following treatments: Tx 1: The socket was filled with BioOss Collagen and covered with a free gingival graft from the palate. Tx 2: The buccal bone plate was augmented using the GBR-technique, the socket was filled with BioOss Collagen and covered with a free gingival graft. Tx 3: The buccal bone plate was forced into a buccal direction using a manual bone spreader. The socket was filled with BioOss Collagen and covered with a free gingival graft from the palate. Tx 4: The socket was filled with BioOss Collagen and a combined free gingival/connective tissue graft was used to cover the socket and for buccal tissue augmentation. For each experimental site, two histological sections were subjected to histometric analysis and evaluated for (i) vertical bone dimensions and (ii) horizontal bone dimensions. All treatment groups showed horizontal and vertical bone loss. The mean vertical bone loss of the buccal bone plate was significantly lower in Tx 4 than in the other groups, while no statistical significant differences could be detected among the groups in the horizontal dimension. Overbuilding the buccal aspect in combination with socket preservation does not seem to be a suitable technique to compensate for the alterations after tooth extraction.
Histologic effects of intentional-socket-assisted orthodontic movement in rabbits.
Yu, Ji-Yeon; Lee, Won; Park, Jae Hyun; Bayome, Mohamed; Kim, Yong; Kook, Yoon-Ah
2012-08-01
This study aimed to evaluate the effect of an intentionally created socket on bone remodeling with orthodontic tooth movement in rabbits. Eighteen male rabbits weighing 3.8 - 4.25 kg were used. An 8-mm deep and 2-mm wide socket was drilled in the bone 1 mm mesial to the right mandibular first premolar. The left first premolar was extracted to serve as an extraction socket. A traction force of 100 cN was applied to the right first premolar and left second premolar. Sections were obtained at the middle third of the moving tooth for both the drilled and extraction sockets and evaluated with hematoxylin and eosin staining and immunohistochemical analyses. The amount of tooth movement and tartrate-resistant acid phosphatase (TRAP)-positive cell count were compared between the 2 groups using the Mann-Whitney U test. At week 2, the distance of tooth movement was significantly higher in the intentional socket group (p < 0.05) than in the extraction socket group. The number of TRAP-positive cells decreased in week 2 but increased in week 3 (p < 0.05). However, there were no significant differences between the groups. Furthermore, results of transforming growth factor (TGF)-β staining revealed no significant differences. The intentional socket group showed greater distance of tooth movement than did the extraction socket group at week 2. Osteoclast counts and results of immunohistochemical analyses suggested elevated bone remodeling in both the groups. Thus, osteotomy may be an effective modality for enhancing tooth movement in orthodontic treatment.
Clinical and histologic outcomes of calcium sulfate in the treatment of postextraction sockets.
Ruga, Emanuele; Gallesio, Cesare; Chiusa, Luigi; Boffano, Paolo
2011-03-01
The aim of this prospective study was to assess the clinical and histologic outcomes obtained with calcium sulfate (CS) used as a filler material in fresh premolar and molar postextraction sockets. Sixty premolar or molar postextraction sockets were filled with CS. Among the 60 grafted sockets, after 3 months, 50 underwent implant placement and clinical assessment. The removal of a sample core of newly generated intrasocket tissue was performed in 19 sockets. Collected samples were sent for histologic examination. The percentage of vital bone, nonvital bone, residual CS, amorphous material, and connective areas in every sample was calculated and recorded. Fifty postextraction regenerated sockets that underwent implant placement 3 months after tooth removal were included in this study.A partial postoperative exposition of the graft was observed in 12 of 50 sockets. At the surgical reentry, the augmented extraction sockets were completely filled by a hard material with an adequate alveolar crest in 41 cases. Histologic examination of the cores revealed that 63.16% of the intrasocket tissue was new vital bone, 2.1% was nonvital bone, 4.74% was fibrous tissue, and 30% was amorphous material. No residual CS was identified in bone cores. This study confirmed that CS is an ideal grafting material. The clinical adequacy aspect of filled sockets at surgical reentry seemed to be indicative of a qualitatively better bone regeneration. Postoperative exposition of graft material after a first intervention seemed to constitute an important risk factor for a worse bone regeneration.
Kobayashi, Toshiki; Orendurff, Michael S; Zhang, Ming; Boone, David A
2014-05-01
The alignment of transtibial prostheses has a systematic effect on the mean socket reaction moments in amputees. However, understanding their individual differences in response to alignment perturbations is also important for prosthetists to fully utilize the socket reaction moments for dynamic alignment in each unique patient. The aim of this study was to investigate individual responses to alignment perturbations in transtibial prostheses with solid-ankle-cushion-heel feet. A custom instrumented prosthesis alignment component was used to measure the socket reaction moments while walking in 11 amputees with transtibial prostheses under 17 alignment conditions, including 3° and 6° of flexion, extension, abduction, and adduction of the socket, 5mm and 10mm of anterior, posterior, lateral, and medial translation of the socket, and an initial baseline alignment. Coronal moments at 30% of stance and maximum sagittal moments were extracted for comparisons from each amputee. In the coronal plane, varus moment at 30% of stance was generally reduced by adduction or medial translation of the socket in all the amputees. In the sagittal plane, extension moment was generally increased by posterior translation or flexion of the socket; however, this was not necessarily the case for all the amputees. Individual responses to alignment perturbations are not always consistent, and prosthetists would need to be aware of this variance when addressing individual socket reaction moments during dynamic alignment in clinical setting. Copyright © 2014 Elsevier Ltd. All rights reserved.
Tang, Jinghua; McGrath, Michael; Laszczak, Piotr; Jiang, Liudi; Bader, Dan L; Moser, David; Zahedi, Saeed
2015-12-01
Design and fitting of artificial limbs to lower limb amputees are largely based on the subjective judgement of the prosthetist. Understanding the science of three-dimensional (3D) dynamic coupling at the residuum/socket interface could potentially aid the design and fitting of the socket. A new method has been developed to characterise the 3D dynamic coupling at the residuum/socket interface using 3D motion capture based on a single case study of a trans-femoral amputee. The new model incorporated a Virtual Residuum Segment (VRS) and a Socket Segment (SS) which combined to form the residuum/socket interface. Angular and axial couplings between the two segments were subsequently determined. Results indicated a non-rigid angular coupling in excess of 10° in the quasi-sagittal plane and an axial coupling of between 21 and 35 mm. The corresponding angular couplings of less than 4° and 2° were estimated in the quasi-coronal and quasi-transverse plane, respectively. We propose that the combined experimental and analytical approach adopted in this case study could aid the iterative socket fitting process and could potentially lead to a new socket design. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Safari, Mohammad Reza; Meier, Margrit Regula
2015-01-01
This review is an attempt to untangle the complexity of transtibial prosthetic socket fit and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. In addition, we identified knowledge gaps, thus providing direction for possible future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, using medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design and type of outcome measure used. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that included the Downs and Black risk of bias assessment checklist. This article presents the results from the systematic review of the quantitative outcomes (n = 27 articles). Trends indicate that vacuum-assisted suction sockets improve gait symmetry, volume control, and residual limb health more than other socket designs. Hydrostatic sockets seem to create less inconsistent socket fittings, reducing a problem that greatly influences outcome measures. Knowledge gaps exist in the understanding of clinically meaningful changes in socket fit and its effect on biomechanical outcomes. Further, safe and comfortable pressure thresholds under various conditions should be determined through a systematic approach.
Fracture Behaviors of Sn-Cu Intermetallic Compound Layer in Ball Grid Array Induced by Thermal Shock
NASA Astrophysics Data System (ADS)
Shen, Jun; Zhai, Dajun; Cao, Zhongming; Zhao, Mali; Pu, Yayun
2014-02-01
In this work, thermal shock reliability testing and finite-element analysis (FEA) of solder joints between ball grid array components and printed circuit boards with Cu pads were used to investigate the failure mechanism of solder interconnections. The morphologies, composition, and thickness of Sn-Cu intermetallic compounds (IMC) at the interface of Sn-3.0Ag-0.5Cu lead-free solder alloy and Cu substrates were investigated by scanning electron microscopy and transmission electron microscopy. Based on the experimental observations and FEA results, it can be recognized that the origin and propagation of cracks are caused primarily by the difference between the coefficient of thermal expansion of different parts of the packaged products, the growth behaviors and roughness of the IMC layer, and the grain size of the solder balls.
CAD/CAM transtibial prosthetic sockets from central fabrication facilities: How accurate are they?
Sanders, Joan E.; Rogers, Ellen L.; Sorenson, Elizabeth A.; Lee, Gregory S.; Abrahamson, Daniel C.
2014-01-01
This research compares transtibial prosthetic sockets made by central fabrication facilities with their corresponding American Academy of Orthotists and Prosthetists (AAOP) electronic shape files and assesses the central fabrication process. We ordered three different socket shapes from each of 10 manufacturers. Then we digitized the sockets using a very accurate custom mechanical digitizer. Results showed that quality varied considerably among the different manufacturers. Four of the companies consistently made sockets within +/−1.1% volume (approximately 1 sock ply) of the AAOP electronic shape file, while six other companies did not. Six of the companies showed consistent undersizing or oversizing in their sockets, which suggests a consistent calibration or manufacturing error. Other companies showed inconsistent sizing or shape distortion, a difficult problem that represents a most challenging limitation for central fabrication facilities. PMID:18247236
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmitz, Roger William; Oh, Yunje
A heating assembly configured for use in mechanical testing at a scale of microns or less. The heating assembly includes a probe tip assembly configured for coupling with a transducer of the mechanical testing system. The probe tip assembly includes a probe tip heater system having a heating element, a probe tip coupled with the probe tip heater system, and a heater socket assembly. The heater socket assembly, in one example, includes a yoke and a heater interface that form a socket within the heater socket assembly. The probe tip heater system, coupled with the probe tip, is slidably receivedmore » and clamped within the socket.« less
NASA Technical Reports Server (NTRS)
Green, Chris; Greenwell, Chris; Brusse, jay; Krus, Dennis; Leidecker, Henning
2009-01-01
During system level testing intermittent and permanent open circuit failures of mated, crimp removable, electrical contact pairs were experienced. The root cause of the failures was determined to be low (but not zero) contact forces applied by the socket contact tines against the engaging pin. The low contact force reduces the effectiveness of the wiping action of the socket tines against the pin. The observed failure mode may be produced when insufficient wiping during mate, demate and small relative movement in use allows for the accumulation of debris or insulating films that electrically separate the contact pair. The investigation identified at least three manufacturing process control problems associated with the socket contacts that enabled shipment of contacts susceptible to developing low contact forces: (1) Improper heat treatment of the socket tines resulting in plastic rather than elastic behavior; (2) Overly thinned socket tines at their base resulting in reduced pin retention forces; (3) insufficient screening tests to identify parts susceptible to the aforementioned failure mechanisms. The results from an extensive screening program of socket contacts utilizing the industry standard contact separation force test procedures are described herein. The investigation shows this method to be capable of identifying initially weak sockets. However, sockets whose contact retention forces may degrade during use may not be screened out by pin retention testing alone. Further investigations are required to correlate low contact retention forces with increased electrical contact resistance in the presence of insulating films that may accumulate in the use environment.
Instrumented socket inserts for sensing interaction at the limb-socket interface.
Swanson, Eric C; McLean, Jake B; Allyn, Katheryn J; Redd, Christian B; Sanders, Joan E
2018-01-01
The objective of this research was to investigate a strategy for designing and fabricating computer-manufactured socket inserts that were embedded with sensors for field monitoring of limb-socket interactions of prosthetic users. An instrumented insert was fabricated for a single trans-tibial prosthesis user that contained three sensor types (proximity sensor, force sensing resistor, and inductive sensor), and the system was evaluated through a sequence of laboratory clinical tests and two days of field use. During in-lab tests 3 proximity sensors accurately distinguish between don and doff states; 3 of 4 force sensing resistors measured gradual pressure increases as weight-bearing increased; and the inductive sensor indicated that as prosthetic socks were added the limb moved farther out of the socket and pistoning amplitude decreased. Multiple sensor types were necessary in analysis of field collected data to interpret how sock changes affected limb-socket interactions. Instrumented socket inserts, with sensors selected to match clinical questions of interest, have the potential to provide important insights to improve patient care. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Kuroshima, Shinichiro; Al-Salihi, Zeina; Yamashita, Junro
2013-02-01
The quality and quantity of bone formed in tooth extraction sockets impact implant therapy. Therefore, the establishment of a new approach to enhance bone formation and to minimize bone resorption is important for the success of implant therapy. In this study, we investigated whether intermittent parathyroid hormone (PTH) therapy enhanced bone formation in grafted sockets. Tooth extractions of the maxillary first molars were performed in rats, and the sockets were grafted with xenograft. Intermittent PTH was administered either for 7 days before extractions, for 14 days after extractions, or both. The effect of PTH therapy on bone formation in the grafted sockets was assessed using microcomputed tomography at 14 days after extractions. PTH therapy for 7 days before extractions was not effective to augment bone fill, whereas PTH therapy for 14 days after operation significantly augmented bone formation in the grafted sockets. Intermittent PTH therapy starting right after tooth extractions significantly enhanced bone fill in the grafted sockets, suggesting that PTH therapy can be a strong asset for the success of the ridge preservation procedure.
2014-10-01
Award Number: W81XWH-10-1-0744 TITLE: Development of Subischial Prosthetic Sockets with Vacuum...REPORT TYPE Annual 3. DATES COVERED 15 Sep 2013 – 14 Sep 2014 4. TITLE AND SUBTITLE Development of Subischial Prosthetic Sockets with Vacuum...to develop a highly flexible sub-ischial prosthetic socket with assisted-vacuum suspension for highly active persons with transfemoral amputation. The
Structural insights from a novel invertebrate triosephosphate isomerase from Litopenaeus vannamei
Lopez-Zavala, Alonso A.; Carrasco-Miranda, Jesus S.; Ramirez-Aguirre, Claudia D.; López-Hidalgo, Marisol; Benitez-Cardoza, Claudia G.; Ochoa-Leyva, Adrian; Cardona-Felix, Cesar S.; Diaz-Quezada, Corina; Rudiño-Piñera, Enrique; Sotelo-Mundo, Rogerio R.; Brieba, Luis G.
2016-01-01
Triosephosphate isomerase (TIM; EC 5.3.1.1) is a key enzyme involved in glycolysis and gluconeogenesis. Glycolysis is one of the most regulated metabolic pathways, however little is known about the structural mechanisms for its regulation in non-model organisms, like crustaceans. To understand the structure and function of this enzyme in invertebrates, we obtained the crystal structure of triosephosphate isomerase from the marine Pacific whiteleg shrimp (Litopenaeus vannamei, LvTIM) in complex with its inhibitor 2-phosphogyceric acid (2-PG) at 1.7 Å resolution. LvTIM assembles as a homodimer with residues 166-176 covering the active site and residue Glu166 interacting with the inhibitor. We found that LvTIM is the least stable TIM characterized to date, with the lowest range of melting temperatures, and with the lowest activation enthalpy associated with the thermal unfolding process reported. In TIMs dimer stabilization is maintained by an interaction of loop 3 by a set of hydrophobic contacts between subunits. Within these contacts, the side chain of a hydrophobic residue of one subunit fits into a cavity created by a set of hydrophobic residues in the neighboring subunit, via a "ball and socket" interaction. LvTIM presents a Cys47 at the "ball" inter-subunit contact indicating that the character of this residue is responsible for the decrease in dimer stability. Mutational studies show that this residue plays a role in dimer stability but is not a solely determinant for dimer formation. PMID:27614148
King, Mark A; Glynn, Jonathan A; Mitchell, Sean R
2011-11-01
A subject-specific angle-driven computer model of a tennis player, combined with a forward dynamics, equipment-specific computer model of tennis ball-racket impacts, was developed to determine the effect of ball-racket impacts on loading at the elbow for one-handed backhand groundstrokes. Matching subject-specific computer simulations of a typical topspin/slice one-handed backhand groundstroke performed by an elite tennis player were done with root mean square differences between performance and matching simulations of < 0.5 degrees over a 50 ms period starting from ball impact. Simulation results suggest that for similar ball-racket impact conditions, the difference in elbow loading for a topspin and slice one-handed backhand groundstroke is relatively small. In this study, the relatively small differences in elbow loading may be due to comparable angle-time histories at the wrist and elbow joints with the major kinematic differences occurring at the shoulder. Using a subject-specific angle-driven computer model combined with a forward dynamics, equipment-specific computer model of tennis ball-racket impacts allows peak internal loading, net impulse, and shock due to ball-racket impact to be calculated which would not otherwise be possible without impractical invasive techniques. This study provides a basis for further investigation of the factors that may increase elbow loading during tennis strokes.
Osaki, Kanji; Okazaki, Ken; Matsubara, Hirokazu; Kuwashima, Umito; Murakami, Koji; Iwamoto, Yukihide
2015-12-01
To investigate the mismatch between the length at the center and the length on the shortest and longest peripheral sides of the femoral tunnel socket, reamed with the transportal (TP), outside-in (OI), and modified transtibial (TT) techniques, in anterior cruciate ligament (ACL) reconstruction. Femoral tunnel drilling was simulated on 3-dimensional bone models from 40 subjects. The tunnel directions used with the TP, OI, and modified TT techniques were previously described. By use of the resulting angle, a femoral tunnel socket of 9 mm in diameter was drilled from the center of the femoral ACL insertion. The virtual femoral tunnel was extracted, and the length mismatch was measured between the center and the shortest and longest peripheral sides of the tunnel socket. The mean socket length mismatch between the center and the shortest peripheral part of the femoral tunnel socket was 4.2 ± 0.9 mm with the TP technique, 5.2 ± 1.3 mm with the OI technique, and 3.2 ± 0.8 mm with the modified TT technique. The mean socket length mismatch between the center and the longest peripheral part of the femoral tunnel socket was 3.5 ± 0.9 mm with the TP technique, 4.8 ± 1.5 mm with the OI technique, and 3.3 ± 1.2 mm with the modified TT technique. The length mismatch was significantly higher when the tunnel socket was created by the OI technique (P < .01). A length mismatch with the tunnel socket exists after reaming with either the TP, OI, or modified TT technique. In particular, there was a significant increase in length mismatch when the tunnel socket was created by the OI technique, and the length mismatch would easily become greater than 5 mm. The surgeon should recognize this mismatch when it is created and measure the femoral tunnel socket. In anatomic ACL reconstruction, a mismatch between the length at the center and the length at periphery of the femoral tunnel socket occurs, and this is increased particularly when using the OI technique. The discrepancy in tunnel length between its center and its periphery could cause an overestimation of the tunnel length that could result in an error in length during graft preparation. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Prosthetic limb sockets from plant-based composite materials.
Campbell, Andrew I; Sexton, Sandra; Schaschke, Carl J; Kinsman, Harry; McLaughlin, Brian; Boyle, Martin
2012-06-01
There is a considerable demand for lower limb prostheses globally due to vascular disease, war, conflict, land mines and natural disasters. Conventional composite materials used for prosthetic limb sockets include acrylic resins, glass and carbon fibres, which produce harmful gasses and dust in their manufacture. To investigate the feasibility of using a renewable plant oil-based polycarbonate-polyurethane copolymer resin and plant fibre composite, instead of conventional materials, to improve safety and accessibility of prosthetic limb manufacture. Experimental, bench research. Test pieces of the resin with a range of plant fibres (10.0% by volume) were prepared and tensile strengths were tested. Test sockets of both conventional composite materials and plant resin with plant fibres were constructed and tested to destruction. Combinations of plant resin and either banana or ramie fibres gave high tensile strengths. The conventional composite material socket and plant resin with ramie composite socket failed at a similar loading, exceeding the ISO 10328 standard. Both wall thickness and fibre-matrix adhesion played a significant role in socket strength. From this limited study we conclude that the plant resin and ramie fibre composite socket has the potential to replace the standard layup. Further mechanical and biocompatibility testing as well as a full economic analysis is required. Using readily sourced and renewable natural fibres and a low-volatile bio-resin has potential to reduce harm to those involved in the manufacture of artificial limb sockets, without compromising socket strength and benefitting clinicians working in poorer countries where safety equipment is scarce. Such composite materials will reduce environmental impact.
Kim, Jung-Ju; Song, Hyun Young; Ben Amara, Heithem; Kyung-Rim, Kang; Koo, Ki-Tae
2016-07-01
Previous studies on ridge preservation focusing on fresh extraction sockets using graft materials for ridge preservation procedures have reported a delay in the tissue modeling and remodeling phases. The objective of this study is to evaluate the effect of hyaluronic acid (HA) on healing of infected sockets. Six beagle dogs were used in this study. Both mandibular third premolars were hemisected, and the distal roots were extracted. Subsequently, periodontal and endodontic lesions were induced at the remaining mesial root. After communication of the periodontal lesion, an endodontic periapical lesion was observed at 4 months, and the mesial roots of both the right and left sides were extracted. HA was applied into the socket of the test group, and no treatment was administered to the other group (control group). Three months after extraction of the mesial roots, the dogs were sacrificed, and histologic evaluations were performed. The sockets were filled by mineralized bone (47.80% ± 6.60%) and bone marrow (50.47% ± 6.38%) in the control group, whereas corresponding values were 63.29% ± 9.78% and 34.73% ± 8.97% for the test group, respectively. There was a statistically significant difference between the groups. Reversal lines and a copious lineup of osteoblasts were observed in the middle and apical parts of the sockets in the test group. An infected socket shows delayed healing of the socket wound, and HA, because of its osteoinductive, bacteriostatic, and anti-inflammatory properties, may improve bone formation and accelerate wound healing in infected sockets.
The effect of instability training on knee joint proprioception and core strength.
Cuğ, Mutlu; Ak, Emre; Ozdemir, Recep Ali; Korkusuz, Feza; Behm, David G
2012-01-01
Although there are many studies demonstrating increased trunk activation under unstable conditions, it is not known whether this increased activation would translate into meaningful trunk strength with a prolonged training program. Additionally, while balance-training programs have been shown to improve stability, their effect on specific joint proprioception is not clear. Thus the objective of this study was to examine training adaptations associated with a 10-week instability-training program. Participants were tested pre- and post-training for trunk extension and flexion strength and knee proprioception. Forty-three participants participated in either a 10-week (3 days per week) instability-training program using Swiss balls and body weight as resistance or a control group (n = 17). The trained group increased (p < 0. 05) trunk extension peak torque/body weight (23.6%) and total work output (20.1%) from pre- to post-training while the control group decreased by 6.8% and 6.7% respectively. The exercise group increased their trunk flexion peak torque/body weight ratios by 18.1% while the control group decreased by 0.4%. Knee proprioception (combined right and left joint repositioning) improved 44.7% from pre- to post-training (p = 0.0006) and persisted (21.5%) for 9 months post-training. In addition there was a side interaction with the position sense of the right knee at 9 months showing 32.1% (p = 0.03) less deviation from the reference angle than the right knee during pre-testing. An instability-training program using Swiss balls with body weight as resistance can provide prolonged improvements in joint proprioception and core strength in previously untrained individuals performing this novel training stress which would contribute to general health. Key pointsAlthough traditional free weight resistance exercises have been recommended as most beneficial for improving strength and power in athletes (Behm et al., 2010b), an IT program using Swiss balls and body weight as a resistance may provide an alternative starting point for the sedentary untrained population.As it is well documented that force or strength is decreased when unbalanced (Behm et al., 2010b) and balance-training programs improve balance (Behm and Kean 2006), this type of instability RT program can provide significant adaptations to improve trunk strength especially with the untrained.This type of training should also be incorporated into a new program as the improvements in joint proprioception may help protect from joint injuries over a protracted period.The finding that improved joint proprioception persists for months after training should be emphasized to those individuals whose training is regularly or inconsistently interrupted.
Earth boring apparatus with multiple welds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolton, J.B.; Crews, S.T.
1981-06-16
A box tool joint member of generally tubular configuration is adapted for securement by welding to one end of a steel tube to form a drill pipe. The box tool joint member comprises a body having a cylindrical outer periphery, an internally threaded socket at one end of the body, and a weld neck of smaller outer diameter than the body adjacent to the other end of the body. A tapered transition piece connecting the neck with the adjacent end of the body provides an elevator shoulder. A correlative pin tool joint member is welded to the opposite end ofmore » the tube to complete the drill pipe. The box tool joint member has an annular band of hard facing over the outer periphery of the transition piece and extending down over the adjacent part of the weld neck and up around the adjacent part of the body. The hard facing is corrosion resistant and has a smooth finished surface. Underneath the hard facing and extending beyond both ends of the hard facing is an annular butter layer of non-hardenable steel. The tool joint member is hardened and tempered after the butter layer is welded into a body groove and before the hard facing is welded on .The butter layer is grooved before the hard facing is welded on.« less
Nasser, Qasiem J.; Gombos, Dan S.; Williams, Michelle D.; Guadagnolo, B. Ashleigh; Morrison, William H.; Garden, Adam S.; Beadle, Beth M.; Canseco, Elvia; Esmaeli, Bita
2012-01-01
Purpose High-dose radiotherapy can cause contracture of the anophthalmic socket, but the incidence of this complication in patients with enucleation for uveal melanoma has not previously been reported. We reviewed the surgical management and outcomes in terms of successful prosthesis wear in patients with severe contracture of the anophthalmic socket treated with high-dose radiotherapy for high-risk uveal melanoma and estimated the relative risk of this complication. Methods The medical records of all consecutive patients enrolled in a prospective uveal-melanoma tissue-banking protocol at our institution who underwent enucleation between January 2003 and December 2010 were reviewed. Patients who underwent adjuvant radiotherapy of the enucleated socket were further studied. Results Of the 68 patients enrolled in the prospective tissue banking protocol, 12 had high-risk histologic features (e.g., extrascleral spread or vortex vein invasion) and were treated with 60 Gy of external-beam radiotherapy after enucleation. Five of these patients (41.7%) experienced severe socket contracture precluding prosthesis wear. The median time to onset of contracture following completion of radiotherapy was 20 months. Three patients underwent surgery, which entailed scar tissue release, oral mucous membrane grafting, and socket reconstruction; 2 patients declined surgery. All 3 patients who had surgery experienced significant improvement of socket contracture that enabled patients to wear a prosthesis again. Conclusion High-dose radiotherapy after enucleation in patients with uveal melanoma caused severe socket contracture and inability to wear a prosthesis in approximately 40% of patients. Surgical repair of the contracted socket using oral mucous membrane grafting can allow resumption of prosthesis wear. PMID:22581085
Design and implementation of a biomimetic turtle hydrofoil for an autonomous underwater vehicle.
Font, Davinia; Tresanchez, Marcel; Siegentahler, Cedric; Pallejà, Tomàs; Teixidó, Mercè; Pradalier, Cedric; Palacin, Jordi
2011-01-01
This paper presents the design and implementation of a turtle hydrofoil for an Autonomous Underwater Vehicle (AUV). The final design of the AUV must have navigation performance like a turtle, which has also been the biomimetic inspiration for the design of the hydrofoil and propulsion system. The hydrofoil design is based on a National Advisory Committee for Aeronautics (NACA) 0014 hydrodynamic profile. During the design stage, four different propulsion systems were compared in terms of propulsion path, compactness, sealing and required power. The final implementation is based on a ball-and-socket mechanism because it is very compact and provides three degrees of freedom (DoF) to the hydrofoil with very few restrictions on the propulsion path. The propulsion obtained with the final implementation of the hydrofoil has been empirically evaluated in a water channel comparing different motion strategies. The results obtained have confirmed that the proposed turtle hydrofoil controlled with a mechanism with three DoF generates can be used in the future implementation of the planned AUV.
2016-10-01
laminated rigid frame to reduce thermal layers, increase flexibility and comfort while retaining ischial containment. In contrast, a Sub-I design has...design is comprised of a flexible interface and minimal laminated rigid frame to reduce thermal layers, increase flexibility and comfort while...AWARD NUMBER: W81XWH-15-1-0410 TITLE: The Effect of Prosthetic Socket Interface Design on Socket Comfort , Residual Limb Health, and Function
Improving socket design to prevent difficult removal of locking screws.
Lin, Chen-Huei; Chao, Ching-Kong; Tang, Yi-Hsuan; Lin, Jinn
2018-03-01
Reports of driver slippage leading to difficult locking screw removals have increased since the adoption of titanium for screw fabrication; the use of titanium is known to cause cross-threading and cold welding. Such problems occur most frequently in screws with hex sockets, and may cause serious surgical complications. This study aimed to improve screw socket design to prevent slippage and difficult screw removal. Three types of small sockets (hex, Torx, and cruciate) and six types of large sockets (hex, Torx, Octatorx, Torx+ I, Torx+ II, and Torx+ III) with screw head diameters of 5.5 mm were manufactured from titanium, and corresponding screwdrivers were manufactured from stainless steel. The screw heads and drivers were mounted on a material testing machine, and torsional tests were conducted to simulate screw usage in clinical settings at two insertion depths: 1 and 2 mm. Ten specimens were tested from each design, and the maximum torque and failure patterns were recorded and compared. For small sockets in 2 mm conditions, the hex with the largest driver core had the highest torque, followed by Torx and cruciate. In these tests, the drivers were twisted off in all specimens. However, under the 1 mm condition, the hex slipped and the torque decreased markedly. Overall, torque was higher for large sockets than for small sockets. The Octatorx, with a large core and simultaneous deformation of the driver and socket lobes, had the highest torque at almost twice that of the small hex. The hex had the lowest torque, a result of slippage in both the 1 and 2 mm conditions. Torx plus designs, with more designed degrees of freedom, were able to maintain a higher driving angle and larger core for higher torque. The hex design showed slipping tendencies with a marked decrease in torque, especially under conditions with inadequate driver engagement. Large sockets allowed for substantial increases in torque. The Torx, Octatorx, and Torx plus designs displayed better performance than the hexes. Improvements to the socket design could effectively prevent slippage and solve difficult screw removal problems. Copyright © 2018. Published by Elsevier Ltd.
Nayak, Chitresh; Singh, Amit; Chaudhary, Himanshu; Unune, Deepak Rajendra
2017-10-23
Technological advances in prosthetics have attracted the curiosity of researchers in monitoring design and developments of the sockets to sustain maximum pressure without any soft tissue damage, skin breakdown, and painful sores. Numerous studies have been reported in the area of pressure measurement at the limb/socket interface, though, the relation between amputee's physiological parameters and the pressure developed at the limb/socket interface is still not studied. Therefore, the purpose of this work is to investigate the effects of patient-specific physiological parameters viz. height, weight, and stump length on the pressure development at the transtibial prosthetic limb/socket interface. Initially, the pressure values at the limb/socket interface were clinically measured during stance and walking conditions for different patients using strain gauges placed at critical locations of the stump. The measured maximum pressure data related to patient's physiological parameters was used to develop an artificial neural network (ANN) model. The effects of physiological parameters on the pressure development at the limb/socket interface were examined using the ANN model. The analyzed results indicated that the weight and stump length significantly affects the maximum pressure values. The outcomes of this work could be an important platform for the design and development of patient-specific prosthetic socket which can endure the maximum pressure conditions at stance and ambulation conditions.
Tolstunov, L
2012-12-01
The aim of this prospective comparative split-mouth study was to evaluate the role of socket irrigation with a normal saline solution routinely used at the end of extraction on the development of alveolar osteitis (AO) after removal of impacted mandibular third molars (MTMs). Thirty-five patients who satisfied the inclusion criteria were involved in the study and underwent extraction of four third-molars. To be included in the study, the mandibular third molars had to be impacted (partial or full bone) and require an osteotomy for extraction with use of a motorised drill. All surgeries were done under local anaesthesia or IV sedation. This was a prospective split-mouth study. The patient's left (assistant) side was a control side; it had a standard extraction technique of an impacted mandibular third molar that required a buccal full-thickness flap, buccal trough (osteotomy) and extraction of the tooth (with or without splitting the tooth into segments), followed by a traditional end-of-surgery debridement protocol consisting of a gentle curettage, bone filing of the socket walls, socket irrigation with approximately 5 ml of sterile normal saline solution and socket suctioning. The patient's right (operator) side was an experimental side; it also had a standard extraction technique of an impacted mandibular third molar at the beginning with a flap and osteotomy, but it was followed by a modified end-of-surgery protocol. It consisted of gentle curettage but the socket was not irrigated and not suctioned. It was simply left to bleed. The gauze was placed on top of the socket for haemostasis on both sides and the patient was asked to bite. On both sides, the buccal flap was positioned back without the suture. All patients were seen for a follow-up appointment four to seven days after the surgery to assess healing and check for symptoms and signs of alveolar osteitis, if present, on both irrigated and non-irrigated sides. This study followed the ethical guidelines of human subjects based on the Helsinki Declaration. Thirty-five patients or 70 sockets were evaluated. Eleven out of 35 patients in the study were subjected to a dry socket syndrome (31.4%). The higher number of AO was likely related to specifics of MTM selection in this study - only impacted (partial and full bone) MTMs were chosen. Among eleven patients with AO, two patients had a bilateral condition. By excluding two patients with bilateral dry sockets from the study, there were nine patients (18 extraction sites) with unilateral AO in the study. Seven out of nine patients (14 extraction sites) developed unilateral dry socket on the control (irrigated) side (77.8%) and only two (four extraction sites) on the experimental (non-irrigated) side (22.2%). Therefore, in this study there were 3.5 times more patients (extraction sites) with dry socket syndrome on the irrigated (control) side than patients (extraction sites) in the non-irrigated (experimental) side. A noticeable difference of dry socket syndromes (77.8% on the irrigated versus 22.2% on non-irrigated side) was demonstrated between the traditional extraction protocol versus modified approach without the end-of-surgery irrigation. The study demonstrated that the post-extraction socket bleeding is very important for the proper uncomplicated socket healing. If it's not washed away with irrigation solution at the end of extraction, the normal blood clot has a higher likelihood to form, and therefore, can potentially lead to an uncomplicated socket healing without development of alveolar osteitis. Socket bleeding at the extraction site creates a favourable environment for the formation of a blood clot - a protective dressing - necessary for a favourable osseous healing of the socket.
Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N
2016-10-01
The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes or other curved cutting devices to preserve the acetabular bone stock. Level III, case-control-study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan
Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.
Reusable vibration resistant integrated circuit mounting socket
Evans, Craig N.
1995-01-01
This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and holds it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuit lead can be removed from the socket without damage either to the lead or to the socket components.
Skill-dependent proximal-to-distal sequence in team-handball throwing.
Wagner, Herbert; Pfusterschmied, Jürgen; Von Duvillard, Serge P; Müller, Erich
2012-01-01
The importance of proximal-to-distal sequencing in human performance throwing has been reported previously. However, a comprehensive comparison of the proximal-to-distal sequence in team-handball throwing in athletes with different training experience and competition is lacking. Therefore, the aim of the study was to compare the ball velocity and proximal-to-distal sequence in the team-handball standing throw with run-up of players of different skill (less experienced, experienced, and elite). Twenty-four male team-handball players (n = 8 for each group) performed five standing throws with run-up with maximal ball velocity and accuracy. Kinematics and ball trajectories were recorded with a Vicon motion capture system and joint movements were calculated. A specific proximal-to-distal sequence, where elbow flexion occurred before shoulder internal rotation, was found in all three groups. These results are in line with previous studies in team-handball. Furthermore, the results of the present study suggest that in the team-handball standing throw with run-up, increased playing experience is associated with an increase in ball velocity as well as a delayed start to trunk flexion.
Systemic review of dry socket: aetiology, treatment, and prevention.
Tarakji, Bassel; Saleh, Lubna Ahmed; Umair, Ayesha; Azzeghaiby, Saleh Nasser; Hanouneh, Salah
2015-04-01
Our systemic review is to make a comprehensive review about the aetiology, treatment and the prevention of dry socket, the inclusion criteria were all the studies that discuss the dry socket and its etiology, treatment and prevention and exclusion criteria were all the studies that discuss the other complications of tooth extraction, the materials and methods used for this systemic review was to search in the Pub Medline database between 2008 to 2013, using specific words "dry socket, aetiology, treatment and prevention" and published in the English language, the articles were screened by abstract for relevance to aetiology, treatment and prevention of dry socket, 82 papers were identified in pub med but a total of 36 out of Publications were included in the final systemic review according to the specific keywords and materials mentioned above. The occurrence of dry socket in an everyday oral surgery or dental practice is unavoidable. The risk factors are smoking, surgical trauma, single extractions, age, sex, medical history, systemic disorder, extraction site, amount of anaesthesia, operator experience, antibiotics use prior to surgery, difficulty of the surgery and the previous surgical site infection in addition to oral Contraceptives, menstrual cycle and immediate postextraction socket irrigation with normal saline. The traditional options of treatment are directed toward palliative care, such as the irrigation of the surgical site, avoiding curetting the extraction socket, Packing with a zinc oxide- eugenol paste on iodoform gauze can be considered to relieve acute pain episodes, there is also new agents in the market can accelerate the healing of the socket such as PRGF and GECB. The prevention methods include avoiding smoking before and after surgery and a traumatic surgery, the use of antibiotics, such as, azithromycin, can be considered, the other preventive measures such as chlorhecidine rinse or gel can be effective in the reduction of dry socket incidence.
Systemic Review of Dry Socket: Aetiology, Treatment, and Prevention
Saleh, Lubna Ahmed; Umair, Ayesha; Azzeghaiby, Saleh Nasser; Hanouneh, Salah
2015-01-01
Our systemic review is to make a comprehensive review about the aetiology, treatment and the prevention of dry socket, the inclusion criteria were all the studies that discuss the dry socket and its etiology, treatment and prevention and exclusion criteria were all the studies that discuss the other complications of tooth extraction, the materials and methods used for this systemic review was to search in the Pub Medline database between 2008 to 2013, using specific words “dry socket, aetiology, treatment and prevention” and published in the English language, the articles were screened by abstract for relevance to aetiology, treatment and prevention of dry socket, 82 papers were identified in pub med but a total of 36 out of Publications were included in the final systemic review according to the specific keywords and materials mentioned above. The occurrence of dry socket in an everyday oral surgery or dental practice is unavoidable. The risk factors are smoking, surgical trauma, single extractions, age, sex, medical history, systemic disorder, extraction site, amount of anaesthesia, operator experience, antibiotics use prior to surgery, difficulty of the surgery and the previous surgical site infection in addition to oral Contraceptives, menstrual cycle and immediate postextraction socket irrigation with normal saline. The traditional options of treatment are directed toward palliative care, such as the irrigation of the surgical site, avoiding curetting the extraction socket, Packing with a zinc oxide– eugenol paste on iodoform gauze can be considered to relieve acute pain episodes, there is also new agents in the market can accelerate the healing of the socket such as PRGF and GECB. The prevention methods include avoiding smoking before and after surgery and a traumatic surgery, the use of antibiotics, such as, azithromycin, can be considered, the other preventive measures such as chlorhecidine rinse or gel can be effective in the reduction of dry socket incidence. PMID:26023661
Hasheminia, Dariush; Moaddabi, Amirhossein; Moradi, Saeid; Moannaei, Mahsa; Issazadeh, Maryam
2018-01-01
Background Dry socket or alveolar osteitis is a delayed healing of alveolar bone after exodontia causing moderate to severe pain 2-4 days after extraction of teeth. Antibacterial agents such as antibiotics and chlorhexidine have been previously proved to prevent or reduce the incidence of dry socket. Betadine is a mixture of iodine and povidone which has bactericidal, antifungal and antiviral effects. The aim of the present study was to evaluate the effect of preoperative povidone iodine 1% mouthwash before surgical extraction of impacted mandibular third molar, however age, gender and oral hygiene were also considered. Material and Methods 189 patients who needed surgical extraction of Pell and Gregory class A and B mandibular third molars were included in this study. The patients who were not willing to participate in the study, took, women who took oral contraceptives or were in the first 22 days of menstrual cycle were excluded. Patients were randomly assigned to control or test group. 97 patients in the test group took preoperative povidone iodine 1% mouthwash and 92 patients in the control group didn’t take any antibiotic or mouthwash. Patients were examined in days 3 and 7 postoperatively for incidence of alveolar osteitis. Results Chi-square test didn’t show any significant relation between dry socket incidence and gender (p value: 0.848) and Oral hygiene (p value: 0.866). However, it revealed a significant relation between age and dry socket incidence (p value: 0.003) and patients older than 30 were reported to have higher incidence of dry socket. Independent T-Test showed a significant difference between the test and control group in incidence of dry socket (p value: 0.036). Conclusions Based on the results of this study povidone iodine 1% mouthwash can decrease dry socket incidence also as the age increases, the incidence of dry socket becomes higher. Key words:Dry socket, impaction, betadine, povidone iodine. PMID:29849968
Hasheminia, Dariush; Moaddabi, Amirhossein; Moradi, Saeid; Soltani, Parisa; Moannaei, Mahsa; Issazadeh, Maryam
2018-05-01
Dry socket or alveolar osteitis is a delayed healing of alveolar bone after exodontia causing moderate to severe pain 2-4 days after extraction of teeth. Antibacterial agents such as antibiotics and chlorhexidine have been previously proved to prevent or reduce the incidence of dry socket. Betadine is a mixture of iodine and povidone which has bactericidal, antifungal and antiviral effects. The aim of the present study was to evaluate the effect of preoperative povidone iodine 1% mouthwash before surgical extraction of impacted mandibular third molar, however age, gender and oral hygiene were also considered. 189 patients who needed surgical extraction of Pell and Gregory class A and B mandibular third molars were included in this study. The patients who were not willing to participate in the study, took, women who took oral contraceptives or were in the first 22 days of menstrual cycle were excluded. Patients were randomly assigned to control or test group. 97 patients in the test group took preoperative povidone iodine 1% mouthwash and 92 patients in the control group didn't take any antibiotic or mouthwash. Patients were examined in days 3 and 7 postoperatively for incidence of alveolar osteitis. Chi-square test didn't show any significant relation between dry socket incidence and gender ( p value: 0.848) and Oral hygiene ( p value: 0.866). However, it revealed a significant relation between age and dry socket incidence ( p value: 0.003) and patients older than 30 were reported to have higher incidence of dry socket. Independent T-Test showed a significant difference between the test and control group in incidence of dry socket ( p value: 0.036). Based on the results of this study povidone iodine 1% mouthwash can decrease dry socket incidence also as the age increases, the incidence of dry socket becomes higher. Key words: Dry socket, impaction, betadine, povidone iodine.
Mechanism of Tennis Racket Spin Performance
NASA Astrophysics Data System (ADS)
Kawazoe, Yoshihiko; Okimoto, Kenji; Okimoto, Keiko
Players often say that some strings provide a better grip and more spin than others, but ball spin did not depend on string type, gauge, or tension in pervious laboratory experiments. There was no research work on spin to uncover what is really happening during an actual tennis impact because of the difficulty of performing the appropriate experiments. The present paper clarified the mechanism of top spin and its improvement by lubrication of strings through the use of high-speed video analysis. It also provided a more detailed explanation of spin behavior by comparing a racket with lubricated strings with the famous “spaghetti” strung racket, which was banned in 1978 by the International Tennis Federation because it used plastic spaghetti tubing over the strings to reduce friction, resulting in excessive ball spin. As the main strings stretch and slide sideways more, the ball is given additional spin due to the restoring force parallel to the string face when the main strings spring back and the ball is released from the strings. Herein, we also showed that the additional spin results in a reduction of shock vibrations of the wrist joint during impact.
An assessment technique for computer-socket manufacturing
Sanders, Joan; Severance, Michael
2015-01-01
An assessment strategy is presented for testing the quality of carving and forming of individual computer aided manufacturing facilities. The strategy is potentially useful to facilities making sockets and companies marketing manufacturing equipment. To execute the strategy, an evaluator fabricates a collection of test models and sockets using the manufacturing suite under evaluation, and then measures their shapes using scanning equipment. Overall socket quality is assessed by comparing socket shapes with electronic file shapes. Then model shapes are compared with electronic file shapes to characterize carving performance. Socket shapes are compared with model shapes to characterize forming performance. The mean radial error (MRE), which is the average difference in radii between the two shapes being compared, provides insight into sizing quality. Inter-quartile range (IQR), the range of radial error for the best matched half of the points on the surfaces being compared, provides insight into shape quality. By determining MRE and IQR for carving and forming separately, the source(s) of socket shape error may be pinpointed. The developed strategy may provide a useful tool to the prosthetics community and industry to help identify problems and limitations in computer aided manufacturing and insight into appropriate modifications to overcome them. PMID:21938663
Antetomaso, Jordan; Kumar, Satish
2018-03-01
Immediate implant placement into fresh extraction sockets versus delayed implants into healed sockets: a systematic review and meta-analysis. Mello CC, Lemos CAA, Verri FR, Dos Santos DM, Goiato MC, Pellizzer EP. Int J Oral Maxillofac Surg 2017; 46(9):1162-77. None TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data. Copyright © 2017 Elsevier Inc. All rights reserved.
HOW DOES ADDING AND REMOVING LIQUID FROM SOCKET BLADDERS AFFECT RESIDUAL LIMB FLUID VOLUME?
Sanders, JE; Cagle, JC; Harrison, DS; Myers, TR; Allyn, KJ
2015-01-01
Adding and removing liquid from socket bladders is a means for people with limb loss to accommodate residual limb volume change. Nineteen people with trans-tibial amputation using their regular prosthetic socket fitted with fluid bladders on the inside socket surface underwent cycles of bladder liquid addition and removal. In each cycle, subjects sat, stood, and walked for 90s with bladder liquid added and then sat, stood, and walking for 90s again with the bladder liquid removed. The amount of bladder liquid added was increased in each cycle. Bioimpedance analysis was implemented to measure residual limb fluid volume. Results showed that the preferred bladder liquid volume was 16.8 mL (s.d.8.4), corresponding to 1.7% (s.d.0.8%) of the average socket volume between the bioimpedance voltage-sensing electrodes. Limb fluid volume driven out of the residual limb when bladder liquid was added was typically not recovered upon subsequent bladder liquid removal. Fifteen of nineteen subjects experienced a gradual limb fluid volume loss over the test session. Care should be taken when implementing adjustable socket technologies in people with limb amputation. Reducing socket volume may accentuate limb fluid volume loss. PMID:24203546
29 CFR 1926.1414 - Wire rope-selection and installation criteria.
Code of Federal Regulations, 2014 CFR
2014-07-01
... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...
29 CFR 1926.1414 - Wire rope-selection and installation criteria.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...
29 CFR 1926.1414 - Wire rope-selection and installation criteria.
Code of Federal Regulations, 2013 CFR
2013-07-01
... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...
Detachable connection for a nuclear reactor fuel assembly
Christiansen, D.W.; Karnesky, R.A.
1983-08-29
A locking connection for releasably attaching a handling socket to the duct tube of a fuel assembly for a nuclear reactor. The connection comprises a load pad housing mechanically attached to the duct tube and a handling socket threadably secured within the housing. A retaining ring is interposed between the housing and the handling socket and is formed with a projection and depression engagable within a cavity and groove of the housing and handling socket, respectively, to form a detachable interlocked connection assembly.
Detachable connection for a nuclear reactor fuel assembly
Christiansen, David W.; Karnesky, Richard A.
1986-01-01
A locking connection for releasably attaching a handling socket to the duct tube of a fuel assembly for a nuclear reactor. The connection comprises a load pad housing mechanically attached to the duct tube and a handling socket threadably secured within the housing. A retaining ring is interposed between the housing and the handling socket and is formed with a projection and depression engageable within a cavity and groove of the housing and handling socket, respectively, to form a detachable interlocked connection assembly.
Kurtul, Bengi Ece; Erdener, Ugur; Mocan, Mehmet Cem; Irkec, Murat; Orhan, Mehmet
2014-01-01
To investigate and compare the cytopathological and clinical effects of amniotic membrane transplantation (AMT) and oral mucosal membrane transplantation (OMMT) in socket contraction. Twelve patients who could not be fitted with ocular prosthesis due to socket contracture were included in this study. Seven patients underwent AMT and 5 patients underwent OMMT. Thirteen patients who had healthy sockets were included as control group. Depth of inferior fornix, degree of inflammation, extent of the socket contracture and socket volume were measured in the preoperative period and at sixth and twelfth weeks postoperatively. Impression cytology of conjunctival fornices and tear transforming growth factor beta-1 (TGFβ1) levels were determined. In the AMT group, socket volume and lower fornix depth values were significantly higher (P=0.030 and P=0.004 respectively) and inflammation levels and impression cytology stages (P=0.037 and P=0.022 respectively) were significantly lower in postoperative period compared to preoperative period. In the OMMT group, no statistical differences were found in terms of clinical parameters, inflammation levels and impression cytology stages of preoperative versus postoperative values. Preoperative tear TGFβ1 levels were higher in AMT and OMMT groups compared to the control group (25.5 ng/mL, 26.3 ng/mL and 21.7 ng/mL respectively). Decreased tear TGFβ1 levels were observed in both the AMT and OMMT groups postoperatively (median decrease value=2.1 ng/mL and 2.7 ng/mL respectively). AMT is associated with postoperative improvement in inferior fornix depth, socket volume, inflammation and impression cytology levels and may be a more proper alternative method than OMMT in the management of socket contracture.
The modular socket system in a rural setting in Indonesia.
Giesberts, Bob; Ennion, Liezel; Hjelmstrom, Olle; Karma, Agusni; Lechler, Knut; Hekman, Edsko; Bergsma, Arjen
2018-06-01
Prosthetic services are inaccessible to people living in rural areas. Systems like the modular socket system have the potential to be fabricated outside of the prosthetic workshop. This study aimed to evaluate the patient's performance and satisfaction with the use of the modular socket system, and the technical feasibility of its implementation in a rural setting. A quantitative longitudinal descriptive study design was followed. A total of 15 persons with a lower limb amputation were fitted with the modular socket system and followed over 4-6 months. Performance was measured using a 2-min walk test, 10-m walk test and mobility and function questionnaire. Satisfaction was measured by the Socket Fit Comfort Score, Prosthesis Evaluation Questionnaire and EuroQoL 5 Dimensions 5 Levels. Notes on technical feasibility were taken at the moment of fitting ( t 0 ), at 1-3 months post fitting ( t 1 ) and at the end evaluation at 4-6 months post fitting ( t 2 ). Performance did not change between t 0 and t 2 . The comfort of the socket fit reduced between t 0 and t 2 . Satisfaction with prosthesis and general health status stayed constant over time. The average fitting-time for the modular socket system was 6.4 h. The modular socket system can be considered a useful alternative for use in rural settings. Clinical relevance The use of the modular socket system is feasible and can improve accessibility to prosthetic technology in rural areas. Experienced prosthetic users were satisfied with the performance and the device. The shorter manufacturing time and use of only hand-held tools makes it an ideal alternative for use in remote and rural settings.
Karakoç, Mehmet; Batmaz, İbrahim; Sariyildiz, Mustafa Akif; Yazmalar, Levent; Aydin, Abdülkadir; Em, Serda
2017-08-01
Patients with amputation need prosthesis to comfortably move around. One of the most important parts of a good prosthesis is the socket. Currently, the most commonly used method is the traditional socket manufacturing method, which involves manual work; however, computer-aided design/computer-aided manufacturing (CAD/CAM) is also being used in the recent years. The present study aimed to investigate the effects of sockets manufactured by traditional and CAD/CAM method on clinical characteristics and quality of life of patients with transtibial amputation. The study included 72 patients with transtibial amputation using prosthesis, 36 of whom had CAD/CAM prosthetic sockets (group 1) and 36 had traditional prosthetic sockets (group 2). Amputation reason, prosthesis lifetime, walking time and distance with prosthesis, pain-free walking time with prosthesis, production time of the prosthesis, and adaptation time to the prosthesis were questioned. Quality of life was assessed using the 36-item Short Form Health Survey questionnaire and the Trinity Amputation and Prosthesis Experience Scales. Walking time and distance and pain-free walking time with prosthesis were significantly better in group 1 than those in group 2. Furthermore, the prosthesis was applied in a significantly shorter time, and socket adaptation time was significantly shorter in group 1. Except emotional role limitation, all 36-item Short Form Healthy Survey questionnaire parameters were significantly better in group 1 than in group 2. Trinity Amputation and Prosthesis Experience Scales activity limitation scores of group 1 were lower, and Trinity Amputation and Prosthesis Experience Scales satisfaction with the prosthesis scores were higher than those in group 2. Our study demonstrated that the sockets manufactured by CAD/CAM methods yield better outcomes in quality of life of patients with transtibial amputation than the sockets manufactured by the traditional method.
Method and system for ultra-precision positioning
Montesanti, Richard C.; Locke, Stanley F.; Thompson, Samuel L.
2005-01-11
An apparatus and method is disclosed for ultra-precision positioning. A slide base provides a foundational support. A slide plate moves with respect to the slide base along a first geometric axis. Either a ball-screw or a piezoelectric actuator working separate or in conjunction displaces the slide plate with respect to the slide base along the first geometric axis. A linking device directs a primary force vector into a center-line of the ball-screw. The linking device consists of a first link which directs a first portion of the primary force vector to an apex point, located along the center-line of the ball-screw, and a second link for directing a second portion of the primary force vector to the apex point. A set of rails, oriented substantially parallel to the center-line of the ball-screw, direct movement of the slide plate with respect to the slide base along the first geometric axis and are positioned such that the apex point falls within a geometric plane formed by the rails. The slide base, the slide plate, the ball-screw, and the linking device together form a slide assembly. Multiple slide assemblies can be distributed about a platform. In such a configuration, the platform may be raised and lowered, or tipped and tilted by jointly or independently displacing the slide plates.
Kobayashi, Toshiki; Orendurff, Michael S; Zhang, Ming; Boone, David A
2013-04-26
Alignment is important for comfortable and stable gait of lower-limb prosthesis users. The magnitude of socket reaction moments in the multiple planes acting simultaneously upon the residual limb may be related to perception of comfort in individuals using prostheses through socket interface pressures. The aim of this study was to investigate the effect of prosthetic alignment changes on sagittal and coronal socket reaction moment interactions (moment-moment curves) and to characterize the curves in 11 individuals with transtibial amputation using novel moment-moment interaction parameters measured by plotting sagittal socket reaction moments versus coronal ones under various alignment conditions. A custom instrumented prosthesis alignment component was used to measure socket reaction moments during walking. Prosthetic alignment was tuned to a nominally aligned condition by a prosthetist, and from this position, angular (3° and 6° of flexion, extension, abduction or adduction of the socket) and translational (5mm and 10mm of anterior, posterior, medial or lateral translation of the socket) alignment changes were performed in either the sagittal or the coronal plane in a randomized manner. A total of 17 alignment conditions were tested. Coronal angulation and translation alignment changes demonstrated similar consistent changes in the moment-moment curves. Sagittal alignment changes demonstrated more complex changes compared to the coronal alignment changes. Effect of sagittal angulations and translations on the moment-moment curves was different during 2nd rocker (mid-stance) with extension malalignment appearing to cause medio-lateral instability. Presentation of coronal and sagittal socket reaction moment interactions may provide useful visual information for prosthetists to understand the biomechanical effects of malalignment of transtibial prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ultra-precision positioning assembly
Montesanti, Richard C.; Locke, Stanley F.; Thompson, Samuel L.
2002-01-01
An apparatus and method is disclosed for ultra-precision positioning. A slide base provides a foundational support. A slide plate moves with respect to the slide base along a first geometric axis. Either a ball-screw or a piezoelectric actuator working separate or in conjunction displaces the slide plate with respect to the slide base along the first geometric axis. A linking device directs a primary force vector into a center-line of the ball-screw. The linking device consists of a first link which directs a first portion of the primary force vector to an apex point, located along the center-line of the ball-screw, and a second link for directing a second portion of the primary force vector to the apex point. A set of rails, oriented substantially parallel to the center-line of the ball-screw, direct movement of the slide plate with respect to the slide base along the first geometric axis and are positioned such that the apex point falls within a geometric plane formed by the rails. The slide base, the slide plate, the ball-screw, and the linking device together form a slide assembly. Multiple slide assemblies can be distributed about a platform. In such a configuration, the platform may be raised and lowered, or tipped and tilted by jointly or independently displacing the slide plates.
Ball catching in children with developmental coordination disorder: control of degrees of freedom.
Utley, Andrea; Steenbergen, Bert; Astill, Sarah Louise
2007-01-01
This study investigated two-handed catching in eight children (four males, four females) aged 7 to 8 years (mean 7y 4mo [SD 3mo]) with developmental coordination disorder (DCD) and their age-matched controls (AMCs). Kinematic data were collected to examine Bernstein's (1967) notion of freezing and releasing degrees of freedom (DF). Participants were asked to catch a ball 30 times, delivered in three blocks of 10 trials. Video analysis showed that children with DCD caught significantly fewer balls than their AMCs (p< or =0.001) counterparts. Kinematic analyses showed that children with DCD exhibited smaller ranges of motion and less variable angular excursions of the elbow joints than their AMCs, and that their elbows are more rigidly coupled (p< or =0.001). These data suggest that children with DCD rigidly fix and couple their limbs to reduce the number of DF actively involved in the task.
The effect of cancer therapies on pediatric anophthalmic sockets.
Shildkrot, Yevgeniy; Kirzhner, Maria; Haik, Barrett G; Qaddoumi, Ibrahim; Rodriguez-Galindo, Carlos; Wilson, Matthew W
2011-12-01
To determine the impact of chemotherapy or external beam radiotherapy (EBRT) on pediatric anophthalmic sockets. A retrospective, nonrandomized, interventional cohort study. A total of 135 sockets of 133 children undergoing enucleation from late 1999 to early 2009 at the St. Jude Children's Research Hospital were included. A retrospective chart review of outcomes after enucleation in patients treated with systemic chemotherapy or orbital EBRT either before or after removal of the eye compared with patients who received no other treatment. Incidence of implant exposure, migration, extrusion, socket contracture, and pyogenic granuloma formation. Retinoblastoma was the primary diagnosis in 128 eyes (95%). Median follow-up was 3.6 years (range, 0.1-9.3 years). Event-free course was observed in 94 sockets (69.6%). Complications included implant exposure (n = 28, 20.7%), socket contracture (n = 16, 11.9%), pyogenic granuloma (n = 9, 6.7%), implant extrusion (n = 3, 2.2%), and migration (n = 2, 1.5%). Exposure resolved in 21 sockets (77.8%) and improved in 2 sockets (11.1%); 1 patient with exposure died. Use of prior, adjuvant, or subsequent chemotherapy increased the long-term risk of exposure (odds ratio [OR] = 3.7; 95% confidence interval [CI], 1.4-9.4), and contracture (OR could not be calculated, P<0.0001). External beam radiotherapy greatly increased the risk of contracture (OR 24.0; 95% CI, 6.9-82.8) and exposure (OR 2.89; 95% CI, 1.1-7.9). In this unique pediatric population with cancer, chemotherapy and EBRT had an additive effect, significantly increasing the incidence of exposure and socket contracture. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
The Effect of Cancer Therapies on Pediatric Anophthalmic Sockets
Shildkrot, Yevgeniy; Kirzhner, Maria; Haik, Barrett G.; Qaddoumi, Ibrahim; Rodriguez-Galindo, Carlos; Wilson, Matthew W.
2012-01-01
Purpose To determine the impact of chemotherapy or external beam radiotherapy (EBRT) on pediatric anophthalmic sockets. Design A retrospective, nonrandomized, interventional cohort study. Participants A total of 135 sockets of 133 children undergoing enucleation from late 1999 to early 2009 at the St. Jude Children’s Research Hospital were included. Methods A retrospective chart review of outcomes after enucleation in patients treated with systemic chemotherapy or orbital EBRT either before or after removal of the eye compared with patients who received no other treatment. Main Outcome Measures Incidence of implant exposure, migration, extrusion, socket contracture, and pyogenic granuloma formation. Results Retinoblastoma was the primary diagnosis in 128 eyes (95%). Median follow-up was 3.6 years (range, 0.1–9.3 years). Event-free course was observed in 94 sockets (69.6%). Complications included implant exposure (n = 28, 20.7%), socket contracture (n = 16, 11.9%), pyogenic granuloma (n = 9, 6.7%), implant extrusion (n = 3, 2.2%), and migration (n = 2, 1.5%). Exposure resolved in 21 sockets (77.8%) and improved in 2 sockets (11.1%); 1 patient with exposure died. Use of prior, adjuvant, or subsequent chemotherapy increased the long-term risk of exposure (odds ratio [OR] = 3.7; 95% confidence interval [CI], 1.4–9.4), and contracture (OR could not be calculated, P<0.0001). External beam radiotherapy greatly increased the risk of contracture (OR 24.0; 95% CI, 6.9–82.8) and exposure (OR 2.89; 95% CI, 1.1–7.9). Conclusions In this unique pediatric population with cancer, chemotherapy and EBRT had an additive effect, significantly increasing the incidence of exposure and socket contracture. PMID:21856015
Poulias, Evmenios; Greenwell, Henry; Hill, Margaret; Morton, Dean; Vidal, Ricardo; Shumway, Brian; Peterson, Thomas L
2013-11-01
Previous studies of ridge preservation showed a loss of ≈18% or 1.5 mm of crestal ridge width in spite of treatment. The primary aim of this randomized, controlled, masked clinical trial is to compare a socket graft to the same treatment plus a buccal overlay graft, both with a polylactide membrane, to determine if loss of ridge width can be prevented by use of an overlay graft. Twelve patients who served as positive controls received an intrasocket mineralized cancellous allograft (socket group), and 12 patients received the same socket graft procedure plus buccal overlay cancellous xenograft (overlay group). Horizontal ridge dimensions were measured with a digital caliper, and vertical ridge changes were measured from a stent. Before implant placement, at 4 months, a trephine core was obtained for histologic analysis. The mean horizontal ridge width at the crest for the socket group decreased from 8.7 ± 1.0 to 7.1 ± 1.5 mm for a mean loss of 1.6 ± 0.8 mm (P <0.05), whereas the same measurement for the overlay group decreased from 8.4 ± 1.4 to 8.1 ± 1.4 mm for a mean loss of 0.3 ± 0.9 mm (P >0.05). The overlay group was significantly different from the socket group (P <0.05). Histologic analysis revealed that the socket group had 35% ± 16% vital bone, and the overlay group had 40% ± 16% (P >0.05). The overlay treatment significantly prevented loss of ridge width and preserved or augmented the buccal contour. The socket and overlay groups healed with a high percentage of vital bone.
The reconstruction of a contracted eye socket using a post-auricular full-thickness skin graft.
Wei, Yi Hsuan; Liao, Shu Lang
2014-05-01
To report the efficacy of a full-thickness skin graft (FTSG) for the reconstruction of a contracted eye socket. A retrospective, non-comparative, interventional case series. This was a retrospective review of patients with a contracted eye socket who underwent socket reconstruction using a post-auricular FTSG from 2001 to 2011 at the National Taiwan University Hospital. The postoperative results including prosthetic fitting, the cosmetic result, and eyelid function were assessed. There were 11 male and 15 female patients, with a mean age of 52.3 ± 15.6 years (range 21 to 76). The duration of the socket contracture varied from three months to three years (average 7.4 ± 8.1 months). The severity of the socket contracture ranged from grade 2 to grade 4, based on Tawfik's classification. The mean follow-up time was 35.7 ± 9.6 months. After socket reconstruction, using a post-auricular FTSG, 96% of the cases (25 of 26) demonstrated a successful prosthetic fitting and a satisfactory cosmetic outcome. Both good eyelid function and a stable fornix depth were maintained during the follow-up time. One case received a second socket reconstruction three months after the first operation, using a FTSG, because of an inadequate lateral fornix. The final result was satisfactory. There were no serious complications, but a granuloma formed in one case, and there was prolonged discharge in one case. The reconstruction of a contracted eye socket using a post-auricular FTSG is an effective method with a high success rate, which causes less discomfort to donor sites and results in few complications.
Prosthetic Correction of Postenucleation Socket Syndrome: A Case Report.
Kamble, Vikas B
2014-12-01
Postenucleation socket syndrome is a frequent late complication of enucleation of eye globe. Several pathophysiological mechanisms have been proposed to account for the symptoms of postenucleation socket syndrome, which include lost orbital volume, superior sulcus deformity, upper eyelid ptosis, lower eyelid laxity, and backward tilt of the prosthesis. The goal of postenucleation socket syndrome treatment is to achieve the best possible functional and esthetic result. The treatment can be either conservative or surgical. For the patient interested in a non-surgical correction, the conservative treatment is simple and non invasive and can be done with prosthesis modification for good positioning, comfort, and mobility. This paper describes prosthetic correction of a patient with postenucleation socket syndrome by modified ocular prosthesis.
Lubricant evaluation of the alpha and beta joints, phase 2
NASA Technical Reports Server (NTRS)
Kannel, J. W.; Stockwell, R. D.
1992-01-01
A research study was conducted to evaluate dry film lubrication of long life space components such as the alpha and beta joints of the Space Station. The problem addressed in the report pertains to the longevity of sputtered MoS2 or ion plated lead films in a rolling contact environment. A special technique was devised for the experiments, which incorporated a coated ball cyclically loaded against a flat plate. At fixed intervals the surface of the coating was photographed at 100X magnification. By computer scanning the photographs, the rate of coating loss was determined. Experimental variables include load and surface finish of the plate. A theory was developed to analyze the state of stress between ball and flat. The stress condition in the ball apparatus was related to the state of stress under rolling contact conditions. Based on the experiments life appeared to decrease with increasing load and increasing surface roughness. An ion plated lead film gave better life than a sputtered MoS2 film. However, by keeping the interfacial shear stress at a low level, adequate coating life was achieved for either coating. For the lead film, the critical stress was about 0.19 GPa (28 ksi). The study dealt only with mechanical wear. Before a coating is selected for a critical space application, other factors such as reaction with atomic oxygen must also be considered.
Shakibaie-M, Behnam
2013-01-01
The aim of this study was to compare the effectiveness of two bone substitute materials for socket preservation after tooth extraction. Extraction sockets in 10 patients were filled with either inorganic bovine bone material (Bio-Oss) or with synthetic material consisting of hydroxyapatite and silicon dioxide (NanoBone). Extraction sockets without filling served as the control. The results demonstrate the effectiveness of the presented protocol for socket preservation and that the choice of a suitable bone substitute material is crucial. The dimensions of the alveolar ridge were significantly better preserved with Bio-Oss than with NanoBone or without treatment. Bio-Oss treatment resulted in better bone quality and quantity for successful implant placement.
Reusable vibration resistant integrated circuit mounting socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, C.N.
1993-12-31
This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and hold it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuitmore » lead can be removed from the socket without damage either to the lead or to the socket components.« less
Reusable vibration resistant integrated circuit mounting socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, C.N.
1995-08-29
This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and holds it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuitmore » lead can be removed from the socket without damage either to the lead or to the socket components. 11 figs.« less
Reis-Filho, Cláudio R; Silva, Elisângela R; Martins, Adalberto B; Pessoa, Fernanda F; Gomes, Paula V N; de Araújo, Mariana S C; Miziara, Melissa N; Alves, José B
2012-05-01
In this study we investigated the possible use of human demineralised dentine matrix (DHDM), obtained from the extracted teeth, as bone graft material and evaluated the expression of vascular endothelial growth factor (VEGF) induced by this material in the healing process of tooth sockets of rats. To evaluate bone regeneration and expression of VEGF induced by DHDM, thirty-two male Wistar rats weighing approximately 200 g were used. After maxillary second molar extraction, the left sockets were filled with DHDM and the right sockets were naturally filled by blood clot (control). The animals were sacrificed at 3, 7, 14 and 21 days after surgery and upper maxillaries were processed for histological, morphometric and immunohistochemical analyses. DHDM was used to evaluate the mechanical effect of bone graft material into sockets. Expression of VEGF was determined by immunohistochemistry in all groups. Our results demonstrated a significant increase in the newly formed bone tissue in sockets of 7, 14 and 21 days and a significant increase in VEGF expression at days 7 and 14 on treated sockets. Our results showed that DHDM increases the expression of VEGF and accelerates the healing process in rats tooth sockets, by stimulating bone deposition and also vessels formation. These results suggest that DHDM has osteoinductive/osteoconductive potential and may represent an efficient grafting material on guided bone regeneration. Copyright © 2011 Elsevier Ltd. All rights reserved.
Zhou, Fengjuan; Zheng, Xiaofei; Xie, Meng; Mo, Anchun; Wu, Hongkun
2017-06-01
To evaluate the microenvironment changes in the sockets substituted with bovine-derived xenografts during the early healing period. After extraction of the right maxillary incisor of Sprague Dawley rats, 48 rats were randomly divided into 2 groups. The extraction sockets of the test group were filled with Bio-Oss, whereas the control group was allowed to heal without intervention. The bone quality of the extraction sockets was observed through micro-CT and immunohistochemistry. Micro-CT scanning showed that the bone mineral density in the test group was significantly higher than that in the control group during the early healing period, whereas immunohistochemistry showed that the bone formation-related factors were significantly different between the test and control groups. The bovine-derived xenografts may interfere with the healing process of the extraction socket in the early healing stage. Bone formation of the extraction socket was delayed after grafting with bone substitute.
Kotsakis, Georgios A; Joachim, Frederic P C; Saroff, Stephen A; Mahesh, Lanka; Prasad, Hari; Rohrer, Michael D
2014-01-01
The objective of this study was to evaluate bone regeneration in 24 sockets grafted with a calcium phosphosilicate putty alloplastic bone substitute. A core was obtained from 17 sockets prior to implant placement for histomorphometry at 5 to 6 months postextraction. Radiographic analysis during the same postextraction healing period showed radiopaque tissue in all sockets. Histomorphometric analysis revealed a mean vital bone content of 31.76% (± 14.20%) and residual graft content of 11.47% (± 8.99%) after a mean healing period of 5.7 months. The high percentage of vital bone in the healed sites in combination with its timely absorption rate suggest that calcium phosphosilicate putty can be a reliable choice for osseous regeneration in extraction sockets.
The influence of joint rigidity on impact efficiency and ball velocity in football kicking.
Peacock, James C A; Ball, Kevin
2018-04-11
Executing any skill with efficiency is important for performance. In football kicking, conflicting and non-significant results have existed between reducing ankle plantarflexion during foot-ball contact with impact efficiency, making it unclear as to its importance as a coaching instruction. The aims of this study were to first validate a mechanical kicking machine with a non-rigid ankle, and secondly compare a rigid to a non-rigid ankle during the impact phase of football kicking. Measures of foot-ball contact for ten trials per ankle configuration were calculated from data recorded at 4000 Hz and compared. The non-rigid ankle was characterised by initial dorsiflexion followed by plantarflexion for the remainder of impact, and based on similarities to punt and instep kicking, was considered valid. Impact efficiency (foot-to-ball speed ratio) was greater for the rigid ankle (rigid = 1.16 ± 0.02; non-rigid = 1.10 ± 0.01; p < 0.001). The rigid ankle was characterised by significantly greater effective mass and significantly less energy losses. Increasing rigidity allowed a greater portion of mass from the shank to be used during the collision. As the ankle remained in plantarflexion at impact end, stored elastic energy was not converted to ball velocity and was considered lost. Increasing rigidity is beneficial for increasing impact efficiency, and therefore ball velocity. Copyright © 2018 Elsevier Ltd. All rights reserved.
49 CFR 570.61 - Suspension system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 6 2012-10-01 2012-10-01 false Suspension system. 570.61 Section 570.61 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... 10,000 Pounds § 570.61 Suspension system. (a) Suspension condition. Ball joint seals shall not be cut...
49 CFR 570.61 - Suspension system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 6 2014-10-01 2014-10-01 false Suspension system. 570.61 Section 570.61 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... 10,000 Pounds § 570.61 Suspension system. (a) Suspension condition. Ball joint seals shall not be cut...
49 CFR 570.8 - Suspension systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 6 2010-10-01 2010-10-01 false Suspension systems. 570.8 Section 570.8 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Pounds or Less § 570.8 Suspension systems. (a) Suspension condition. Ball joint seals shall not be cut or...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
Double arch mirror study. Part 1: Preliminary engineering report
NASA Technical Reports Server (NTRS)
Vukobratovich, D.; Hillman, D.
1983-01-01
In the proposed design, the NASA AMES 20-in double arch mirror is supported by three clamp and flexure assemblies. The mirror clamp consists of a T-shaped Invar-36 member that goes into a similarly shaped socket in the back of the mirror. The mirror socket is made oversize and contacts the clamp only along the conical surface. The clamp is preloaded by a spring washer and pulls the mirror into contact with the flexure. The clamp is then inserted into the mirror socket through a cutout, is rotated 90 deg, and is then pinned in place. Loading conditions considered in socket design are discussed as well as stress in the socket and clamp. Flexure geometry and stress are examined as well as the effects of flexure error and of mirror cell error.
Manavella, Valeria; Romano, Federica; Garrone, Federica; Terzini, Mara; Bignardi, Cristina; Aimetti, Mario
2017-06-01
The aim of this study was to present and validate a novel procedure for the quantitative volumetric assessment of extraction sockets that combines cone-beam computed tomography (CBCT) and image processing techniques. The CBCT dataset of 9 severely resorbed extraction sockets was analyzed by means of two image processing software, Image J and Mimics, using manual and automated segmentation techniques. They were also applied on 5-mm spherical aluminum markers of known volume and on a polyvinyl chloride model of one alveolar socket scanned with Micro-CT to test the accuracy. Statistical differences in alveolar socket volume were found between the different methods of volumetric analysis (P<0.0001). The automated segmentation using Mimics was the most reliable and accurate method with a relative error of 1.5%, considerably smaller than the error of 7% and of 10% introduced by the manual method using Mimics and by the automated method using ImageJ. The currently proposed automated segmentation protocol for the three-dimensional rendering of alveolar sockets showed more accurate results, excellent inter-observer similarity and increased user friendliness. The clinical application of this method enables a three-dimensional evaluation of extraction socket healing after the reconstructive procedures and during the follow-up visits.
Gerard, David A; Carlson, Eric R; Gotcher, Jack E; Pickett, David O
2014-01-01
This study was conducted with 2 purposes. The first was to determine the effect of a single dose of zoledronic acid (ZA) on the healing of a tooth extraction socket in dogs. The second was to determine if placement of recombinant human bone morphogenetic protein-2 (rhBMP-2)/absorbable collagen sponge (ACS) - INFUSE, (Medtronic, Memphis, TN) into these extraction sockets would inhibit the inhibition on bone healing and remodeling by ZA. Nine adult female beagle dogs (2 to 3 yr old) were placed into 3 groups of 3 dogs each. Group I received 15 mL of sterile saline intravenously; group II received 2.5 mg of ZA intravenously; and group III received 5 mg of ZA intravenously. Forty-five days after treatment, all dogs underwent extraction of noncontiguous right and left mandibular first molars and second premolars. In group I, the right mandibular extraction sockets had nothing placed in them, whereas the left mandibular sockets had only ACS placed in them. In groups II and III, the right mandibular sockets had rhBMP-2/ACS placed in them, whereas the left mandibular sockets had only ACS placed. All extraction sockets were surgically closed. Tetracycline was given intravenously 5 and 12 days later, and all animals were euthanized 15 days after tooth extraction. The extraction sockets and rib and femur samples were harvested immediately after euthanasia, processed, and studied microscopically. A single dose of ZA significantly inhibited healing and bone remodeling in the area of the tooth extractions. The combination of rhBMP-2/ACS appeared to over-ride some of the bone remodeling inhibition of the ZA and increased bone fill in the extraction sites, and remodeling activity in the area was noted. The effects of rhBMP-2/ACS were confined to the area of the extraction sockets because bone activity at distant sites was not influenced. A single dose of ZA administered intravenously inhibits early healing of tooth extraction sockets and bone remodeling in this animal model. The combination of rhBMP-2/ACS significantly increased bone fill and bone remodeling in these areas, negating much of the effect of the ZA. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Samitier, C Beatriz; Guirao, Lluis; Costea, Maria; Camós, Josep M; Pleguezuelos, Eulogio
2016-02-01
Lower limb amputation leads to impaired balance, ambulation, and transfers. Proper fit of the prosthesis is a determining factor for successful ambulation. Vacuum-assisted socket systems extract air from the socket, which decreases pistoning and probability of soft-tissue injuries and increases proprioception and socket comfort. To investigate the effect of vacuum-assisted socket system on transtibial amputees' performance-based and perceived balance, transfers, and gait. Quasi-experimental before-and-after study. Subjects were initially assessed using their prosthesis with the regular socket and re-evaluated 4 weeks after fitting including the vacuum-assisted socket system. We evaluated the mobility grade using Medicare Functional Classification Level, Berg Balance Scale, Four Square Step Test, Timed Up and Go Test, the 6-Min Walk Test, the Locomotor Capabilities Index, Satisfaction with Prosthesis (SAT-PRO questionnaire), and Houghton Scale. A total of 16 unilateral transtibial dysvascular amputees, mean age 65.12 (standard deviation = 10.15) years. Using the vacuum-assisted socket system, the patients significantly improved in balance, gait, and transfers: scores of the Berg Balance Scale increased from 45.75 (standard deviation = 6.91) to 49.06 (standard deviation = 5.62) (p < 0.01), Four Square Step Test decreased from 18.18 (standard deviation = 3.84) s to 14.97 (3.9) s (p < 0.01), Timed Up and Go Test decreased from 14.3 (standard deviation = 3.29) s to 11.56 (2.46) s (p < 0.01). The distance walked in the 6-Min Walk Test increased from 288.53 (standard deviation = 59.57) m to 321.38 (standard deviation = 72.81) m (p < 0.01). Vacuum-assisted socket systems are useful for improving balance, gait, and transfers in over-50-year-old dysvascular transtibial amputees. This study gives more insight into the use of vacuum-assisted socket systems to improve elderly transtibial dysvascular amputees' functionality and decrease their risk of falls. The use of an additional distal valve in the socket should be considered in patients with a lower activity level. © The International Society for Prosthetics and Orthotics 2014.
Vignoletti, Fabio; Discepoli, Nicola; Müller, Anna; de Sanctis, Massimo; Muñoz, Fernando; Sanz, Mariano
2012-01-01
The purpose of this investigation is to describe histologically the undisturbed healing of fresh extraction sockets when compared to immediate implant placement. In eight beagle dogs, after extraction of the 3P3 and 4P4, implants were inserted into the distal sockets of the premolars, while the mesial sockets were left to heal spontaneously. Each animal provided four socket sites (control) and four implant sites (test). After 6 weeks, animals were sacrificed and tissue blocks were dissected, prepared for ground sectioning. The relative vertical buccal bone resorption in relation to the lingual bone was similar in both test and control groups. At immediate implant sites, however, the absolute buccal bone loss observed was 2.32 (SD 0.36) mm, what may indicate that while an apical shift of both the buccal and lingual bone crest occurred at the implant sites, this may not happen in naturally healing sockets. The results from this investigation showed that after tooth extraction the buccal socket wall underwent bone resorption at both test and control sites. This resorption appeared to be more pronounced at the implant sites, although the limitations of the histological evaluation method utilized preclude a definite conclusion. © 2011 John Wiley & Sons A/S.
Jiang, Xi; Zhang, Yu; Chen, Bo; Lin, Ye
2017-04-01
Extraction socket remodeling and ridge preservation strategies have been extensively explored. To evaluate the efficacy of applying a micro-titanium stent as a pressure bearing device on extraction socket remodeling of maxillary anterior tooth. Twenty-four patients with a extraction socket of maxillary incisor were treated with spontaneous healing (control group) or by applying a micro-titanium stent as a facial pressure bearing device over the facial bone wall (test group). Two virtual models obtained from cone beam computed tomography data before extraction and 4 months after healing were 3-dimenionally superimposed. Facial bone wall resorption, extraction socket remodeling features and ridge width preservation rate were determined and compared between the groups. Thin facial bone wall resulted in marked resorption in both groups. The greatest palatal shifting distance of facial bone located at the coronal level in the control group, but middle level in the test group. Compared with the original extraction socket, 87.61 ± 5.88% ridge width was preserved in the test group and 55.09 ± 14.46% in the control group. Due to the facial pressure bearing property, the rigid micro-titanium stent might preserve the ridge width and alter the resorption features of extraction socket. © 2016 Wiley Periodicals, Inc.
Heberer, Susanne; Wustlich, Alexander; Lage, Hermann; Nelson, John J; Nelson, Katja
2012-01-01
The aim of the present clinical study was the evaluation of the osteogenic potential of mesenchymal cells embedded in the provisional matrix of non-augmented and with Bio-Oss collagen-augmented human extraction sockets after 6 weeks of healing time. Twenty-five patients with 47 extraction sites participated in the present study. After tooth removal, the extraction sockets were augmented with Bio-Oss collagen or not augmented. At implant placement, bone biopsies of the extraction sockets were obtained. The immunohistochemical analysis of the osteogenic potential of the mesenchymal cells in the provisional matrix was performed using three monoclonal antibodies: core-binding factor α1 (Cbfa1)/runt-related protein (Runx)2, osteonectin (OSN/secreted protein acidic and rich in cyst [SPARC]) and osteocalcin (OC). The statistical analysis was performed using two-factorial analysis for repeated measures, Mann-Whitney U-test and Spearman's rank-order correlation coefficient. Of 47 extraction sockets examined, 17 sockets demonstrated an almost complete ossification. Hence, the provisional matrix of the 30 remaining extraction sockets (21 non-augmented, 9 augmented) was immunohistochemically investigated. No evidence of acute or chronic inflammation was noted in any of the specimens. In the provisional matrix of the non-grafted socket, the median amount of Cbfa1/Runx2-positive cells was 72.3%, of OSN (SPARC) 66.9% and of OC 23.4%, whereas in the grafted sockets the median rate of immunopositive cells staining with Cbfa1/Runx2 was 73.3%, of OSN (SPARC) 61.4% and of OC 20.1%. There was no significant difference in the proportion of positive cells expressed by Cbfa1/Runx2, OSN/SPARC and OC between the grafted and non-grafted socket. Furthermore, the cell density did not correlate to the quantity of stained cells independent of the used proteins. After a 6-week healing period, the provisional matrix was demonstrated to have a high proportion of cells displaying a maturation of mature osteoprogenitor cells to osteoblasts. The grafting procedure did not influence the quantity of osteogenic cells in the extraction socket. © 2011 John Wiley & Sons A/S.
Convertible socket for pressure gauge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bissell, R.D.
1990-01-01
This patent describes a pressure gauge having a case in which is disposed a Bourdon tube and a base socket connected to the Bourdon tube for placing the tube in pressure communication with a fluid pressure source. Base socket has a rearward face and a bottom face with respect to the gauge adjacent openings defined through the case and an internal passage communication with the tube. It includes means for connecting a source of fluid pressure to the socket selectively through one of the case openings to the bottom face or the rearward face.
Requena-Calla, Silvana; Funes-Rumiche, Italo
2016-04-01
Dry socket is one of the most studied complications in dentistry and several studies have sought an effective and safe method for its prevention and treatment. The aim of this study was to evaluate the effectiveness of intra-alveolar gel chlorhexidine in preventing dry socket after the surgical removal of third molars. The sample involved the treatment of 40 patients who required extraction of third molars impacted, which were randomly assigned to research groups: experimental group (chlorhexidine gel 0.12%) and control group (placebo gel). Performed the extraction was administered 1 mL of chlorhexidine gel or 1 mL of placebo gel within the socket. The removal of suture was on the fifth postoperative day in which the presence or absence of dry socket was evaluated. No relationship between the appearance of dry socket after application of chlorhexidine gel or placebo gel (X2 test, p = 0.311) was found. However, significant differences (U Mann-Whitney test, p = 0.036) in the pain presented on the fifth postoperative day were evident (VAS). The administration of intra-alveolar chlorhexidine gel 0.12% could generate a better response to postoperative pain after the removal of third molars. Third molar surgery, dry socket, chorhexidine gel.
NASA Astrophysics Data System (ADS)
Liu, Weiping; Lee, Ning-Cheng
2007-07-01
The impact reliability of solder joints in electronic packages is critical to the lifetime of electronic products, especially those portable devices using area array packages such as ball-grid array (BGA) and chip-scale packages (CSP). Currently, SnAgCu (SAC) solders are most widely used for lead-free applications. However, BGA and CSP solder joints using SAC alloys are fragile and prone to premature interfacial failure, especially under shock loading. To further enhance impact reliability, a family of SAC alloys doped with a small amount of additives such as Mn, Ce, Ti, Bi, and Y was developed. The effects of doping elements on drop test performance, creep resistance, and microstructure of the solder joints were investigated, and the solder joints made with the modified alloys exhibited significantly higher impact reliability.
Kobayashi, Toshiki; Arabian, Adam K.; Orendurff, Michael S.; Rosenbaum-Chou, Teri G.; Boone, David A.
2014-01-01
Background Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. Methods A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Findings Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. Interpretation The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. PMID:24315709
Moghaddas, Hamid; Amjadi, Mohammad Reza; Naghsh, Narges
2012-11-01
Alveolar ridge preservation following tooth extraction has the ability to maintain the ridge dimensions and allow the implant placement in an ideal position fulfilling both functional and aesthetic results. The aim of this study was to evaluate the efficacy of the palatal connective tissue as a biological membrane for socket preservation with demineralized freeze-dried bone allograft (DFDBA). Twelve extraction sites were treated with DFDBA with (case group) and without (control group) using autogenous palatal connective tissue membrane before placement of implants. Alveolar width and height, amount of keratinized tissue, and gingival level were measured at pre-determined points using a surgical stent at two times, the time of socket preservation surgery. In both groups a decrease in all socket dimensions was found. The average decrease in socket width, height, keratinized tissue, and gingival level in case group was 1.16, 0.72, 3.58, and 1.27 mm, and in control group was 2.08, 0.86, 4.52, and 1.58 mm respectively. Statistical analysis showed that decrease in socket width (P = 0.012), keratinized tissue (P ≤ 0.001), and gingival level (P = 0.031) in case group was significantly lower than that of the control group. Results showed no meaningful difference in socket height changes when compared with case and control groups (P = 0.148). Under the limits of this study, connective tissue membrane could preserve socket width, amount of keratinized tissue, and the gingival level more effectively than DFDBA alone.
Sharma, Ashish; Aggarwal, Nimish; Rastogi, Sanjay; Choudhury, Rupshikha; Tripathi, Siddhi
2017-01-01
To assess the efficacy of platelet-rich fibrin (PRF) on the pain and healing of the extraction socket related with established alveolar osteitis (dry socket, AO) after the removal of maxillary and mandibular molars. One hundred consecutive adult patients with age group ranging from 18 to 40 years along with established dry socket after maxillary and mandibular molar extractions who have not received any treatment for the same were included in this single-arm clinical trial. PRF was placed in the maxillary and mandibular molar extraction sockets after adequate irrigation of the socket. All the patients evaluated for the various study variables which include pain, degree of inflammation, and healthy granulation tissue formation (wound healing) at the 1 st , 3 rd , 7 th , and 14 th post-PRF placement day in the alveolar socket. Data were analyzed using Shapiro-Wilk's test, Chi-square test and/or Student's t -test, Friedman's test, Wilcoxon signed-rank test, and Bonferroni test, with the significance level set at P < 0.05. There was significant reduction in pain associated with AO at the 3 rd and 7 th post-PRF placement day in the extraction socket along with mark decrease in the degree of inflammation at the 3 rd post-PRF placement day, and there was better wound healing by the end of the 2 nd week. The use of PRF in this clinical trial illustrates the promising results in terms of reduced pain and better healing in the patients with sustained AO.
Surface EMG and intra-socket force measurement to control a prosthetic device
NASA Astrophysics Data System (ADS)
Sanford, Joe; Patterson, Rita; Popa, Dan
2015-06-01
Surface electromyography (SEMG) has been shown to be a robust and reliable interaction method allowing for basic control of powered prosthetic devices. Research has shown a marked decrease in EMG-classification efficiency throughout activities of daily life due to socket shift and movement and fatigue as well as changes in degree of fit of the socket throughout the subject's lifetime. Users with the most severe levels of amputation require the most complex devices with the greatest number of degrees of freedom. Controlling complex dexterous devices with limited available inputs requires the addition of sensing and interaction modalities. However, the larger the amputation severity, the fewer viable SEMG sites are available as control inputs. Previous work reported the use of intra-socket pressure, as measured during wrist flexion and extension, and has shown that it is possible to control a powered prosthetic device with pressure sensors. In this paper, we present data correlations of SEMG data with intra-socket pressure data. Surface EMG sensors and force sensors were housed within a simulated prosthetic cuff fit to a healthy-limbed subject. EMG and intra-socket force data was collected from inside the cuff as a subject performed pre-defined grip motions with their dominant hand. Data fusion algorithms were explored and allowed a subject to use both intra-socket pressure and SEMG data as control inputs for a powered prosthetic device. This additional input modality allows for an improvement in input classification as well as information regarding socket fit through out activities of daily life.
2012-10-01
materials to facilitate dissemination of this technique. 15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted...an appropriate mechanical pump to create suitable vacuum for suspension of the prosthesis ...sockets of highly active prosthesis users
Kobayashi, Toshiki; Orendurff, Michael S.; Arabian, Adam K.; Rosenbaum-Chou, Teri G.; Boone, David A.
2014-01-01
The alignment of a lower limb prosthesis affects the way load is transferred to the residual limb through the socket, and this load is critically important for the comfort and function of the prosthesis. Both magnitude and duration of the moment are important factors that may affect the residual limb health. Moment impulse is a well-accepted measurement that incorporates both factors via moment–time integrals. The aim of this study was to investigate the effect of alignment changes on the socket reaction moment impulse in transtibial prostheses. Ten amputees with transtibial prostheses participated in this study. The socket reaction moment impulse was measured at a self-selected walking speed using a Smart Pyramid™ in 25 alignment conditions, including a nominal alignment (clinically aligned by a prosthetist), as well as angle malalignments of 2°, 4° and 6° (abduction, adduction, extension and flexion) and translation malalignments of 5 mm, 10 mm and 15 mm (lateral, medial, anterior and posterior). The socket reaction moment impulse of the nominal alignment was compared for each condition. The relationship between the alignment and the socket reaction moment impulse was clearly observed in the coronal angle, coronal translation and sagittal translation alignment changes. However, this relationship was not evident in the sagittal angle alignment changes. The results of this study suggested that the socket reaction moment impulse could potentially serve as a valuable parameter to assist the alignment tuning process for transtibial prostheses. Further study is needed to investigate the influence of the socket reaction moment impulse on the residual limb health. PMID:24612718
Evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin
Tumer, Celal; Ugur, Omer; Vatankulu, Betul
2015-01-01
Objective: The aim of this study was to determine whether the use of platelet rich fibrin (PRF) improved the healing of extraction sockets. Study Design: A total of 20 patients with bilateral soft tissue impacted mandibular third molars were included in this study. The left and right third molars were extracted during the same session. Subsequently, the PRF membrane was randomly administered to one of the extraction sockets, whereas the contra lateral sockets were left without treatment. On postoperative 30. and 90. days, panoramic images and bone scintigrams were taken to evaluate the bone healing between PRF-treated and non-PRF-treated sockets. Also, periodontal evaluation was performed in the same control sessions. Dependent group t test for paired samples was used for statistical analysis. Results: The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 30 and 90 days post operatively. Radio opacity that can show the bone healing on panoramic images were measured by Image J programmer and they did not differ significantly. Also periodontal values did not differ significantly. Conclusions: PRF might not lead to enhanced bone healing in impacted mandibular third molar extraction sockets 30 and 90 days after surgery. It is thought that PRF has the potential characteristics of an autologous fibrin matrix and can accelerate the healing. To better understand the effects of PRF on healing, further research is warranted with larger sample sizes. Key words:PRF, scintigraphy, healing, extraction sockets. PMID:25475771
An Amino Acid Code for β-sheet Packing Structure
Joo, Hyun; Tsai, Jerry
2014-01-01
To understand the relationship between protein sequence and structure, this work extends the knob-socket model in an investigation of β-sheet packing. Over a comprehensive set of β-sheet folds, the contacts between residues were used to identify packing cliques: sets of residues that all contact each other. These packing cliques were then classified based on size and contact order. From this analysis, the 2 types of 4 residue packing cliques necessary to describe β-sheet packing were characterized. Both occur between 2 adjacent hydrogen bonded β-strands. First, defining the secondary structure packing within β-sheets, the combined socket or XY:HG pocket consists of 4 residues i,i+2 on one strand and j,j+2 on the other. Second, characterizing the tertiary packing between β-sheets, the knob-socket XY:H+B consists of a 3 residue XY:H socket (i,i+2 on one strand and j on the other) packed against a knob B residue (residue k distant in sequence). Depending on the packing depth of the knob B residue, 2 types of knob-sockets are found: side-chain and main-chain sockets. The amino acid composition of the pockets and knob-sockets reveal the sequence specificity of β-sheet packing. For β-sheet formation, the XY:HG pocket clearly shows sequence specificity of amino acids. For tertiary packing, the XY:H+B side-chain and main-chain sockets exhibit distinct amino acid preferences at each position. These relationships define an amino acid code for β-sheet structure and provide an intuitive topological mapping of β-sheet packing. PMID:24668690
Mozzati, Marco; Gallesio, Giorgia; di Romana, Sara; Bergamasco, Laura; Pol, Renato
2014-03-01
To evaluate the efficacy of plasma-rich growth factor (PRGF) in improving socket healing after tooth extraction in diabetic patients. This was a split-mouth study in which each patient also served as the control: the study socket was treated with PRGF, whereas the control socket underwent natural healing. The outcome variables were the Healing Index, residual socket volume, visual analog scale score, postsurgical complications, and outcome of a patient questionnaire. The investigation considered the impact of hyperglycemia, glycated hemoglobin, End Organ Disease Score, and smoking habits. Follow-up included 4 postextraction checkups over a 21-day period. Pairs of correlated continuous variables were analyzed with the Wilcoxon test, independent continuous variables with the Mann-Whitney test, and categorical variables with the χ(2) test or Fisher test. From January 2012 to December 2012, 34 patients affected by insulin-dependent diabetes mellitus underwent contemporary bilateral extractions of homologous teeth. The treatment-versus-control postoperative comparison showed that PRGF resulted in significantly smaller residual socket volumes and better Healing Indices from days 3 to 14. The patients' questionnaire outcomes were unanimously in favor of PRGF treatment. The small sample of patients with glycemia values of at least 240 mg/dL showed worse Healing Index and minor socket decreases. PRGF application after extraction improved the healing process in diabetic patients by accelerating socket closure (epithelialization) and tissue maturation, proving the association between PRGF use and improved wound healing in diabetic patients. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Platelet rich fibrin in the management of established dry socket
2017-01-01
Objectives Dry socket may occur secondary to the removal of any tooth. However, most dry socket cases develop in the third molar region. Dry socket is multifactorial in nature and has been treated using various modalities with varying success rates. This study assessed the efficacy of platelet rich fibrin (PRF) in established dry socket. Materials and Methods Ten patients of either sex aged from 41 to 64 years with established dry socket according to established criteria were treated using PRF. Evaluation was performed by observing the reduction of pain using visual analogue scale, analgesic tablet use over the follow-up period, and healing parameters. Results Pain was reduced on the first day in all patients with decreased analgesic use. Pain was drastically reduced during follow-up on the first, second, third, and seventh days with a fall in pain score of 0 to 1 after the first day alone. The pain scores of all patients decreased to 1 by the first day except in one patient, and the scores decreased to 0 in all patients after 48 hours. Total analgesic intake ranged from 2 to 6 tablets (aceclofenac 100 mg per tablet) over the follow-up period of 7 days. Healing was satisfactory in all patients by the end of the seventh day. Conclusion PRF showed early pain reduction in established dry socket with minimal analgesic intake. No patients had allergic reactions to PRF as it is derived from the patient's own blood. PRF showed good wound healing. Our study suggests that PRF should be considered as a treatment modality for established dry socket. PMID:28770156
Platelet rich fibrin in the management of established dry socket.
Chakravarthi, Srinivas
2017-06-01
Dry socket may occur secondary to the removal of any tooth. However, most dry socket cases develop in the third molar region. Dry socket is multifactorial in nature and has been treated using various modalities with varying success rates. This study assessed the efficacy of platelet rich fibrin (PRF) in established dry socket. Ten patients of either sex aged from 41 to 64 years with established dry socket according to established criteria were treated using PRF. Evaluation was performed by observing the reduction of pain using visual analogue scale, analgesic tablet use over the follow-up period, and healing parameters. Pain was reduced on the first day in all patients with decreased analgesic use. Pain was drastically reduced during follow-up on the first, second, third, and seventh days with a fall in pain score of 0 to 1 after the first day alone. The pain scores of all patients decreased to 1 by the first day except in one patient, and the scores decreased to 0 in all patients after 48 hours. Total analgesic intake ranged from 2 to 6 tablets (aceclofenac 100 mg per tablet) over the follow-up period of 7 days. Healing was satisfactory in all patients by the end of the seventh day. PRF showed early pain reduction in established dry socket with minimal analgesic intake. No patients had allergic reactions to PRF as it is derived from the patient's own blood. PRF showed good wound healing. Our study suggests that PRF should be considered as a treatment modality for established dry socket.
A new directly moulded patellar-tendon-bearing socket.
Boot, D A; Young, N J
1985-08-01
Silicone rubbers and casting tapes individually have previously been used in the manufacture of sockets (Swanson, 1972; Sweitzer, 1973; Ruder, 1977; Graves, 1980; Aqualite, 1982). The authors believe that the present combination of these materials to manufacture a directly moulded socket with a complete silicone rubber lining of variable thickness has not previously been described. The new socket, after addition of the modular components, allows fitting of an aligned below-knee prosthesis within three hours. The socket (Fig. 1.) is made directly on the below-knee stump, can be completed with experience in an hour and does not require the use of specialized equipment. The socket consists of an outer supportive Scotchflex layer inside which is a lining of soft smooth biocompatible silicone rubber of deliberately variable thickness to allow pressure tolerant areas to accept more load and pressure sensitive areas to accept less load (Fig.2). The thicker areas of silicone are produced by applying carefully cut Plastazote pads to the pressure sensitive areas. The thickness and extent of the pads is individually assessed according to the estimated sensitivity of the particular area (Fig. 3). The Scotchflex socket is then manufactured directly on the below-knee stump with these pads applied. The pads are then removed prior to insertion of a semi-liquid silicone rubber. Thus, when the socket with the liquid silicone rubber is re-applied to the stump, the space produced by the pads is filled by the rubber which then sets at room temperature. In this way a layer of variable thickness is produced.(ABSTRACT TRUNCATED AT 250 WORDS)
Extraction socket sealing using palatal gingival grafts and resorbable collagen membranes.
Kim, Sang-Yun; Kim, Young-Kyun; Kim, Hyun-Suk; Yun, Pil-Young; Kim, Su-Gwan; Choi, Yong-Hun
2017-12-01
Socket sealing surgery is performed for the preservation of the form and volume of the soft tissue by covering the resulting socket with autogenous soft tissue graft or membrane barriers. This procedure is usually necessary to improve the esthetic results of the maxillary anterior or premolar areas. This study retrospectively investigated cases involving the open membrane technique or socket sealing surgery with a palatal gingival graft or collagen membrane where implant placement and bone grafting were performed immediately after tooth extraction. From January 2005 to December 2008, socket sealing surgery was performed in 24 patients, and 25 implants were placed. All implants were successful in the follow-up period. In the palatal gingival graft group, the mean marginal bone loss was 1.17 mm during the mean follow-up period of 81.0 months. In the collagen membrane group, the mean marginal bone loss was 1.23 mm during the mean follow-up period of 76.9 months. There was no significant difference between the two groups. Consequently, socket sealing surgery is effective at minimizing the loss of soft tissue and alveolar bone.
Development of a residuum/socket interface simulator for lower limb prosthetics.
McGrath, Michael Paul; Gao, Jianliang; Tang, Jinghua; Laszczak, Piotr; Jiang, Liudi; Bader, Dan; Moser, David; Zahedi, Saeed
2017-03-01
Mechanical coupling at the interface between lower limb residua and prosthetic sockets plays an important role in assessing socket fitting and tissue health. However, most research lab-based lower limb prosthetic simulators to-date have implemented a rigid socket coupling. This study describes the fabrication and implementation of a lower limb residuum/socket interface simulator, designed to reproduce the forces and moments present during the key loading phases of amputee walking. An artificial residuum made with model bones encased in silicone was used, mimicking the compliant mechanical loading of a real residuum/socket interface. A 6-degree-of-freedom load cell measured the overall kinetics, having previously been incorporated into an amputee's prosthesis to collect reference data. The developed simulator was compared to a setup where a rigid pylon replaced the artificial residuum. A maximum uniaxial load of 850 N was applied, comparable to the peak vertical ground reaction force component during amputee walking. Load cell outputs from both pylon and residuum setups were compared. During weight acceptance, when including the artificial residuum, compression decreased by 10%, while during push off, sagittal bending and anterior-posterior shear showed a 25% increase and 34% decrease, respectively. Such notable difference by including a compliant residuum further highlighted the need for such an interface simulator. Subsequently, the simulator was adjusted to produce key load cell outputs briefly aligning with those from amputee walking. Force sensing resistors were deployed at load bearing anatomic locations on the residuum/socket interface to measure pressures and were compared to those cited in the literature for similar locations. The development of such a novel simulator provides an objective adjunct, using commonly available mechanical test machines. It could potentially be used to provide further insight into socket design, fit and the complex load transfer mechanics at the residuum/socket interface, as well as to evaluate the structural performance of prostheses.
A Microprocessor Development System for the Intel 8748 Microcomputer.
1979-12-01
their ready availability, it was decided to build the system on a 4 x 6 Vector plugboard with a 44 pin connect- or and which was predrilled for wirewrap...8748, additional sockets were provided in a 4 socket mother board. These sockets accept the standard 44 pin Vector plugboard . It is recommended that
Probe-And-Socket Fasteners For Robotic Assembly
NASA Technical Reports Server (NTRS)
Nyberg, Karen
1995-01-01
Self-alignment and simplicity of actuation make mechanism amenable to robotic assembly. Includes socket, mounted on structure at worksite, and probe, mounted on piece of equipment to be attached to structure at socket. Probe-and-socket mechanism used in conjunction with fixed target aiding in placement of end effector of robot during grasping, and with handle or handles on structure. Intended to enable robot to set up workstation in hostile environment. Workstation then used by astronaut, aquanaut, or other human, spending minimum time in environment. Human concentrates on performing quality work rather than on setting up equipment, with consequent reduction of risk.
Postoperative Complications of Dermis-Fat Autografts in the Anophthalmic Socket.
Starks, Victoria; Freitag, Suzanne K
2018-01-01
Reconstruction of the anophthalmic socket allows the use of an ocular prosthesis and rehabilitation of facial appearance. Dermis-fat grafting is one option in volume augmentation of the anophthalmic socket and presents unique benefits, including increased surface area within the socket and the ability to grow with pediatric patients. Postoperative complications of this procedure are relatively common. Minor complications, such as graft hirsutism, keratinization, and conjunctival cysts or granulomas, are managed easily by observation or simple intervention. Major complications, such as graft atrophy, infection, or ulceration, may prevent good prosthesis fit and may require return to the operating room.
A case series of anophthalmic socket cysts excised utilising fibrin sealant.
Wong, Yun; Clarke, Lucy; Lau, Gordon
2017-10-23
Anophthalmic socket cysts are challenging to remove and incomplete excision has been shown to increase the risk of recurrence. This case series describes a novel technique utilising the fibrin sealant Tisseel (Baxter AG, Vienna, Austria) to retain the socket cyst integrity during surgical removal to facilitate its complete excision. Five patients were included and followed up for a minimum of 1 year, and there were no signs of recurrence in any of the cases. The surgical technique is described and illustrated. This technique is a safe way of simplifying challenging socket cyst surgery.
NASA Astrophysics Data System (ADS)
Wang, Song; Li, Junhui; Lu, Junzhe; Tyagi, Rajnesh; Liao, Zhenhua; Feng, Pingfa; Liu, Weiqiang
2017-05-01
The artificial cervical disk was simplified and considered as a ball-on-socket model with the material configuration of ultra-high molecular weight polyethylene and Ti6Al4V (PE-on-TC4). In order to improve the wear resistance, an optimized thermal oxidation (TO) coating was applied on TC4 component. The long-term wear behavior of the model was assessed in vitro using a wear simulator under 10 million cycles (MC) testing intervals. The biological behavior was investigated by bone marrow-derived mesenchymal stem cells (BMSCs) cell attachment and cell viability/proliferation assays, respectively. The total average wear rate for PE/TC4 pair was found to be 0.81 mg/MC, whereas the same was about 0.96 mg/MC for PE/TO pair. The wear rate of the metal has been neglected in comparison with that of the mating polymer. PE component was found to suffer severe damage characterized by scratches, fatigue cracks and arc-shaped wear grooves on the edge zone of ball. The dominant wear mechanism was abrasion for metal component while the dominant failure mechanism was a mix of plowing, fatigue and plastic deformation for polymer component. TO coating improved the cell attachment property of TC4, and the cell viability results were also quite good. TO coating protected TC4 from being plowed and avoided the release of toxic metal ions. However, this intensified the wear of PE component. Considering the biotribological and biological behavior in totality, TO coating could still be promising when applied in articulation surfaces.
Safari, Mohammad Reza; Meier, Margrit Regula
2015-01-01
This review is an attempt to untangle the complexity of transtibial prosthetic socket fit, determine the most important characteristic for a successful fitting, and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. Further, it is intended to provide directions for future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and used medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design or type of outcome measure. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that incorporated the Downs and Black risk of bias assessment checklist. Results for the qualitative outcomes (n = 19 articles) are synthesized. Total surface bearing sockets lead to greater activity levels and satisfaction in active persons with amputation, those with a traumatic cause of amputation, and younger persons with amputation than patellar tendon bearing sockets. Evidence on vacuum-assisted suction and hydrostatic sockets is inadequate, and further studies are much needed. To improve the scientific basis for prescription, comparison of and correlation between mechanical properties of interface material, socket designs, user characteristics, and outcome measures should be conducted and reported in future studies.
Yu, H J; Jia, P; Lv, Z; Qiu, L X
2017-04-01
The aim of this study was to analyze and compare the long-term clinical outcomes of mature third molar autotransplantation in surgically created sockets and fresh extraction sockets with regard to survival and functional success rates. A total of 65 third molars with completely formed roots were autotransplanted in 60 patients (average age 33.1 years). Thirty-six of the teeth were autotransplanted into surgically created sockets with or without guided bone regeneration (GBR; delayed autotransplantation), while 29 were autotransplanted into fresh extraction sockets (immediate autotransplantation; control group). All patients underwent annual clinical and radiographic examinations (average follow-up 9.9 years, range 7-13 years). The survival rates for the control, GBR, and no GBR groups were 93.1%, 95.2%, and 80.0%, respectively, with no significant differences among the groups. There were no statistically significant differences among the groups with regard to the frequency of inflammatory root resorption or root ankylosis. Age did not influence the clinical outcomes. These results suggest that the autotransplantation of third molars with completely formed roots is effective in both surgically created and fresh extraction sockets and provides a high long-term success rate if cases are selected and treated appropriately. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
LaPrè, A K; Price, M A; Wedge, R D; Umberger, B R; Sup, Frank C
2018-04-01
Musculoskeletal modeling and marker-based motion capture techniques are commonly used to quantify the motions of body segments, and the forces acting on them during human gait. However, when these techniques are applied to analyze the gait of people with lower limb loss, the clinically relevant interaction between the residual limb and prosthesis socket is typically overlooked. It is known that there is considerable motion and loading at the residuum-socket interface, yet traditional gait analysis techniques do not account for these factors due to the inability to place tracking markers on the residual limb inside of the socket. In the present work, we used a global optimization technique and anatomical constraints to estimate the motion and loading at the residuum-socket interface as part of standard gait analysis procedures. We systematically evaluated a range of parameters related to the residuum-socket interface, such as the number of degrees of freedom, and determined the configuration that yields the best compromise between faithfully tracking experimental marker positions while yielding anatomically realistic residuum-socket kinematics and loads that agree with data from the literature. Application of the present model to gait analysis for people with lower limb loss will deepen our understanding of the biomechanics of walking with a prosthesis, which should facilitate the development of enhanced rehabilitation protocols and improved assistive devices. Copyright © 2017 John Wiley & Sons, Ltd.
Electromigration effect on intermetallic growth and Young's modulus in SAC solder joint
NASA Astrophysics Data System (ADS)
Xu, Luhua; Pang, John H. L.; Ren, Fei; Tu, K. N.
2006-12-01
Solid-state intermetallic compound (IMC) growth behavior plays and important role in solder joint reliability of electronic packaging assemblies. The directional impact of electromigration (EM) on the growth of interfacial IMCs in Ni/SAC/Ni, Cu/SAC/Ni single BGA ball solder joint, and fine pitch ball-grid-array (FPBGA) at the anode and cathode sides is reported in this study. When the solder joint was subjected to a current density of 5,000 A/cm2 at 125°C or 150°C, IMC layer growth on the anode interface was faster than that on the cathode interface, and both were faster than isothermal aging due to the Joule heating effect. The EM affects the IMC growth rate, as well as the composition and mechanical properties. The Young’s modulus and hardness were measured by the nanoindentation continuous stiffness measurement (CSM) from planar IMC surfaces after EM exposure. Different values were observed at the anode and cathode. The energy-dispersive x-ray (EDX) line scan analysis was conducted at the interface from the cathode to anode to study the presence of species; Ni was found in the anode IMC at SAC/Cu in the Ni/SAC/Cu joint, but not detected when the current was reverse. Electron-probe microanalysis (EPMA) measurement on the Ni/SAC/Ni specimen also confirmed the polarized Ni and Cu distributions in cathode and anode IMCs, which were (Ni0.57Cu0.43)3Sn4 and (Cu0.73Ni0.27)6Sn5, respectively. Thus, the Young’s moduli of the IMC are 141 and 175 GPa, respectively.
The Effect of Instability Training on Knee Joint Proprioception and Core Strength
Cuğ, Mutlu; Ak, Emre; Özdemir, Recep Ali; Korkusuz, Feza; Behm, David G
2012-01-01
Although there are many studies demonstrating increased trunk activation under unstable conditions, it is not known whether this increased activation would translate into meaningful trunk strength with a prolonged training program. Additionally, while balance-training programs have been shown to improve stability, their effect on specific joint proprioception is not clear. Thus the objective of this study was to examine training adaptations associated with a 10-week instability-training program. Participants were tested pre- and post-training for trunk extension and flexion strength and knee proprioception. Forty-three participants participated in either a 10-week (3 days per week) instability-training program using Swiss balls and body weight as resistance or a control group (n = 17). The trained group increased (p < 0. 05) trunk extension peak torque/body weight (23.6%) and total work output (20.1%) from pre- to post-training while the control group decreased by 6.8% and 6.7% respectively. The exercise group increased their trunk flexion peak torque/body weight ratios by 18.1% while the control group decreased by 0.4%. Knee proprioception (combined right and left joint repositioning) improved 44.7% from pre- to post-training (p = 0.0006) and persisted (21.5%) for 9 months post-training. In addition there was a side interaction with the position sense of the right knee at 9 months showing 32.1% (p = 0.03) less deviation from the reference angle than the right knee during pre-testing. An instability-training program using Swiss balls with body weight as resistance can provide prolonged improvements in joint proprioception and core strength in previously untrained individuals performing this novel training stress which would contribute to general health. Key pointsAlthough traditional free weight resistance exercises have been recommended as most beneficial for improving strength and power in athletes (Behm et al., 2010b), an IT program using Swiss balls and body weight as a resistance may provide an alternative starting point for the sedentary untrained population.As it is well documented that force or strength is decreased when unbalanced (Behm et al., 2010b) and balance-training programs improve balance (Behm and Kean 2006), this type of instability RT program can provide significant adaptations to improve trunk strength especially with the untrained.This type of training should also be incorporated into a new program as the improvements in joint proprioception may help protect from joint injuries over a protracted period.The finding that improved joint proprioception persists for months after training should be emphasized to those individuals whose training is regularly or inconsistently interrupted. PMID:24149355
2013-10-01
15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted suspension 16. SECURITY CLASSIFICATION OF: 17...vacuum for suspension of the prosthesis ...14 Task 6 Determine range of volumes to be evacuated from transfemoral sockets of highly active prosthesis users
The possible nature of socket stars in H II regions
NASA Technical Reports Server (NTRS)
Castelaz, Michael W.
1990-01-01
Close inspection of faint stars (V of about 14 mag) in H II regions show that they appear to be surrounded by circumstellar envelopes of about 10 arcsecs in diameter (as reported by Feibelman in 1989). The present premise is that the sockets are envelopes of obscuring dust which should emit a measurable amount of infrared radiation based on a simple thermal equilibrium model. A search of literature shows that, of 36 socket stars listed by Feibelman, 17 have been measured in the infrared. Of the 17, 14 show excess IR emission. This is very strong evidence that the socket stars are really stars with circumstellar envelopes. Socket stars may be a new type of astronomical object or well-known astronomical objects in environments or evolutionary states not previously seen.
El Chaar, Edgard; Oshman, Sarah; Cicero, Giuseppe; Castano, Alejandro; Dinoi, Cinzia; Soltani, Leila; Lee, Yoonjung Nicole
Localized ridge resorption, the consequence of socket collapse, following tooth extraction in the anterior maxilla can adversely affect esthetics, function, and future implant placement. Immediate grafting of extraction sockets may help preserve natural ridge contours, but a lack of available soft tissue can compromise the final esthetic outcome. The presented modified rotated palatal pedicle connective tissue flap is a useful technique for simultaneous soft tissue coverage and augmentation of grafted sockets to improve esthetic outcome. This article delineates its advantages through the presentation of a four-case series using this new technique.
Chang, Hao-Hueng; Wang, Yin-Lin; Chiang, Yu-Chih; Chen, Yen-Liang; Chuang, Yu-Horng; Tsai, Shang-Jye; Heish, Kuo-Huang; Lin, Feng-Huei; Lin, Chun-Pin
2014-01-01
A novel chitosan-γPGA polyelectrolyte complex hydrogel (C-PGA) has been developed and proven to be an effective dressing for wound healing. The purpose of this study was to evaluate if C-PGA could promote new bone formation in the alveolar socket following tooth extraction. An animal model was proposed using radiography and histomorphology simultaneously to analyze the symmetrical sections of Wistar rats. The upper incisors of Wistar rats were extracted and the extraction sockets were randomly treated with gelatin sponge, neat chitosan, C-PGA, or received no treatment. The extraction sockets of selected rats from each group were evaluated at 1, 2, 4, or 6 wk post-extraction. The results of radiography and histopathology indicated that the extraction sockets treated with C-PGA exhibited lamellar bone formation (6.5%) as early as 2 wk after the extraction was performed. Moreover, the degree of new bone formation was significantly higher (P < 0.05) in the extraction sockets treated with C-PGA at 6 wk post-extraction than that in the other study groups. In this study, we demonstrated that the proposed animal model involving symmetrical sections and simultaneous radiography and histomorphology evaluation is feasible. We also conclude that the novel C-PGA has great potential for new bone formation in the alveolar socket following tooth extraction. PMID:24658174
Prevention and treatment of dry socket.
Dodson, Tom
2013-03-01
Cochrane Oral Health Group Trials Register, Cochrane Central Register of Controlled Trials (CENTRAL), Medline and Embase databases were searched together with reference lists of identified articles. Topic experts and organisations were also contacted. Only randomised controlled trials were considered and there were no restrictions regarding language or date of publication. Data abstraction and risk of bias assessment were conducted in duplicate and Cochrane statistical guidelines were followed. The GRADE tool was used to assess the quality of the body of evidence. Twenty-one trials with 2570 participants were included. Eighteen trials (2376 participants) related to prevention and three to treatment (194 participants). Six studies were at high risk of bias, 14 of unclear risk and one study at low risk. There was moderate evidence (four trials, 750 participants) that chlorhexidine mouthrinses (0.12% and 0.2% concentrations) both before and after extraction(s) prevented approximately 42% of dry socket(s) with a RR of 0.58 (95% CI 0.43 to 0.78; P < 0.001). The number of patients needed to be treated (0.12% and 0.2%) with chlorhexidine rinse to prevent one patient having dry socket (NNT) was 232 (95% CI 176 to 417), 47 (95% CI 35 to 84) and 8 (95% CI 6 to 14) at prevalences of dry socket of 1%, 5% and 30% respectively. Thee was moderate evidence (two trials, in 133 participants) that placing chlorhexidine gel (0.2%) after extractions prevented approximately 58% of dry socket(s) with a RR of 0.42 (95% CI 0.21 to 0.87; P = 0.02) with NNT of 173 (95% CI 127 to 770), 35 (95% CI 25 to 154) and 6 (95% CI 5 to 26) at prevalences of dry socket of 1%, 5% and 30% respectively. There was insufficient evidence to determine the effects of other intrasocket preventive interventions or interventions to treat dry socket. There is some evidence that rinsing with chlorhexidine (0.12% and 0.2%) or placing chlorhexidine gel (0.2%) in the sockets of extracted teeth, provides a benefit in preventing dry socket. There was insufficient evidence to determine the effects of the other 10 preventative interventions each evaluated in single studies. There was insufficient evidence to determine the effects of any of the interventions to treat dry socket. The present review found some evidence for the association of minor adverse reactions with use of 0.12%, 0.2% and 2% chlorhexidine mouthrinses, though most studies were not designed to detect the presence of hypersensitivity reactions to mouthwash as part of the study protocol. No adverse events were reported in relation to the use of 0.2% chlorhexidine gel placed directly into a socket (though previous allergy to chlorhexidine was an exclusion criterion in these trials). In view of recent reports in the UK of two cases of serious adverse events associated with irrigation of dry socket with chlorhexidine mouthrinse, it is recommended that all members of the dental team prescribing chlorhexidine products are aware of the potential for both minor and serious adverse side effects. It is beyond the scope of this review to describe and detail The Cochrane Collaboration. The reader can seek out more information at http://www.cochrane.org/. In brief, a systematic review supported and published by the Cochrane group represents the gold standard to support clinical decision-making.
Kobayashi, Toshiki; Arabian, Adam K; Orendurff, Michael S; Rosenbaum-Chou, Teri G; Boone, David A
2014-01-01
Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
Preliminary evaluation of hermetic JT/LJT/R P connector socket contact design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baca, J.R.F.
1991-10-01
This report presents a precursory examination of a number of issues pertaining to socket contacts in hermetic connectors. The principal issues addressed are high-contact resistance and contact chatter (circuit discontinuities). Efforts examining the characteristics of the existing socket contact design, the possibility of connector/contact rework, quick-fix solutions, and contact redesigns are summarized.
Kobayashi, Toshiki; Orendurff, Michael S; Arabian, Adam K; Rosenbaum-Chou, Teri G; Boone, David A
2014-04-11
The alignment of a lower limb prosthesis affects the way load is transferred to the residual limb through the socket, and this load is critically important for the comfort and function of the prosthesis. Both magnitude and duration of the moment are important factors that may affect the residual limb health. Moment impulse is a well-accepted measurement that incorporates both factors via moment-time integrals. The aim of this study was to investigate the effect of alignment changes on the socket reaction moment impulse in transtibial prostheses. Ten amputees with transtibial prostheses participated in this study. The socket reaction moment impulse was measured at a self-selected walking speed using a Smart Pyramid in 25 alignment conditions, including a nominal alignment (clinically aligned by a prosthetist), as well as angle malalignments of 2°, 4° and 6° (abduction, adduction, extension and flexion) and translation malalignments of 5 mm, 10 mm and 15 mm (lateral, medial, anterior and posterior). The socket reaction moment impulse of the nominal alignment was compared for each condition. The relationship between the alignment and the socket reaction moment impulse was clearly observed in the coronal angle, coronal translation and sagittal translation alignment changes. However, this relationship was not evident in the sagittal angle alignment changes. The results of this study suggested that the socket reaction moment impulse could potentially serve as a valuable parameter to assist the alignment tuning process for transtibial prostheses. Further study is needed to investigate the influence of the socket reaction moment impulse on the residual limb health. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mandour, Sameh S; Elmazar, Hesham M; Marey, Hatem M; Rahman, Ahmed K Abdel; Sakr, Rokia A
2016-12-01
To evaluate the use of intraoperative topical application of mitomycin C (MMC) for managing cases of recurrent socket contraction. A prospective comparative randomized study was carried out on 40 patients suffering from contracted sockets. They were randomly enrolled into 2 groups. Group A included 20 patients who had a surgery to treat contracted socket without augmentation with MMC. Group B patients had an MMC-augmented repair for the contracted socket. Patients were followed up over a period of 12 months for changes in inferior fornix (IF) depth and ability to retain the ocular prosthesis. At the end of the follow-up period, postoperative IF depth was significantly deeper in group B (with MMC) than in group A (without MMC). As well, 75% of the patients in group B could maintain the prosthetic eye shell, whereas only 35% of group A could maintain the prosthesis. This study shows that using intraoperative MMC (0.2 mg/mL) in contracted socket reconstruction plays a significant role in maintaining prosthetic eye. To the best of our knowledge, this study is the first to use MMC on a relatively large scale of patients with contracted socket. However, the follow-up period was relatively short and further work is required to verify the effect of MMC on a longer follow-up period.
Jee, Jeong-Hyun; Lee, Wan; Lee, Byung Do
2010-08-01
Many dental patients take bisphosphonates to reduce the risk of hip and vertebral fractures. In vivo micro-computed tomography (micro-CT) was used to examine the longitudinal inhibitory effect of alendronate on the healing of extraction sockets in ovariectomized rats. Twenty 5-week-old Sprague-Dawley rats were assigned randomly to 1 of 3 groups: sham-operated (n = 5), and 2 ovariectomized (OVX) groups: saline treated (0.1 mL/100 g/d, n = 7) and alendronate treated (1 mg/kg/d, n = 8). Before micro-CT scanning, the left maxillary first molars of the rats were extracted. In vivo micro-CT (spatial resolution 50 x 50 mum) of the jaw was performed at baseline and at 2-week intervals for 6 weeks. Alveolar-bone radiographic densities and dimensions were analyzed with repeated measures analysis of variance. The bony healing patterns of the extraction sockets were also evaluated in each group. The radiographic socket densities of the sham-treated and OVX-alendronate groups significantly increased during the first 4 weeks after extraction (P < .05). At 2 weeks, the radiographic densities of the sockets in the OVX-saline group increased, but the increase was significantly lower than for the other groups at 4 weeks (P < .05). Newly formed bone was identified in the extraction sockets in all groups 2 to 6 weeks after extraction. There was a significant loss of alveolar ridge height at the second week postextraction compared with baseline, and at the fourth week compared with the second week (P < .05) except in the alendronate group. Alendronate appears to promote the healing of extraction sockets in estrogen-deficient rats and helps resist the loss of alveolar bone adjacent to extraction sockets. Copyright 2010 Mosby, Inc. All rights reserved.
Mourits, Daphne L; Remmers, Jelmer S; Tan, Stevie H; Moll, Annette C; Hartong, Dyonne T
2018-04-03
To introduce a novel technique to design individually customized conformers for postenucleation sockets with dermis fat implants. We use a 3-dimensional scan of the frontal face/orbit and eyelid contour to design an individualized conformer. This polymethylmetacrylate printed conformer is adapted to patients' socket, palpebral fissures, horizontal eyelid aperture, curvature of the eyelids, and mean diameter of patients' contralateral eye. Sutures through holes in the inferior part of the conformer and in the extension can be placed to fixate the conformer and anchor fornix deepening sutures. A correct fitting conformer can be printed and attached to the socket and eyelids. The shape of this conformer can be used subsequently postsurgically to design the ocular prosthesis. Presurgical planning is important to anticipate for a functional socket to adequately fit an artificial eye. The presented technique using 3-dimensional imaging, designing, and printing promises to prevent conformer extrusion and forniceal shortening.
Simpson, G; Fisher, C; Wright, D K
2001-01-01
Continuing earlier studies into the relationship between the residual limb, liner and socket in transtibial amputees, we describe a geometrically accurate non-linear model simulating the donning of a liner and then a socket. The socket is rigid and rectified and the liner is a polyurethane geltype which is accurately described using non-linear (Mooney-Rivlin) material properties. The soft tissue of the residual limb is modelled as homogeneous, non-linear and hyperelastic and the bone structure within the residual limb is taken as rigid. The work gives an indication of how the stress induced by the process of donning the rigid socket is redistributed by the liner. Ultimately we hope to understand how the liner design might be modified to reduce discomfort. The ANSYS finite element code, version 5.6 is used.
Cooled electronic system with thermal spreaders coupling electronics cards to cold rails
Chainer, Timothy J; Gaynes, Michael A; Graybill, David P; Iyengar, Madhusudan K; Kamath, Vinod; Kochuparambil, Bejoy J; Schmidt, Roger R; Schultz, Mark D; Simco, Daniel P; Steinke, Mark E
2013-07-23
Liquid-cooled electronic systems are provided which include an electronic assembly having an electronics card and a socket with a latch at one end. The latch facilitates securing of the card within the socket or removal of the card from the socket. A liquid-cooled cold rail is disposed at the one end of the socket, and a thermal spreader couples the electronics card to the cold rail. The thermal spreader includes first and second thermal transfer plates coupled to first and second surfaces on opposite sides of the card, and thermally conductive extensions extending from end edges of the plates, which couple the respective transfer plates to the liquid-cooled cold rail. The thermally conductive extensions are disposed to the sides of the latch, and the card is securable within or removable from the socket using the latch without removing the cold rail or the thermal spreader.
Conservative Socket Regeneration with Buccal Wall Defect Using Guided Tissue.
Al-Juboori, Mohammed Jasim
2016-01-01
Progressive alveolar bone resorption after tooth extraction may lead to surgical and prosthetic-driven difficulties, especially when deciding to use a dental implant to replace the extracted tooth. This case report discusses an irreparable lower left second premolar tooth with a periodontal lesion on the buccal side. A preservative tooth extraction was performed. Then, the socket was grafted with bovine bone, a collagen membrane was placed between the buccal bone and the attached gingiva, covering the bone dehiscence buccally, and the socket without a flap was raised. After a 6-month healing period, there was minimal socket width resorption and a shallow buccal vestibule. The implant was placed with high primary stability and sufficient buccal plate thickness. In conclusion, this guided tissue regeneration technique can minimize alveolar bone resorption in a socket with buccal dehiscence, but technical difficulties and shallowing of the buccal vestibule still exist.
Aggarwal, Himanshi; Singh, Saumyendra V; Kumar, Pradeep; Kumar Singh, Arun
2015-06-01
One of the most common tumors of the eye diagnosed in childhood is retinoblastoma, which mandates enucleation with adjunctive chemotherapy and radiotherapy to save the patient's life. The most common late enucleation complication is post-enucleation socket syndrome (PESS), which poses a management dilemma for the prosthodontist and surgeon, along with being a major esthetic concern for the patient. The reconstruction of such sockets is complex. The purpose of this clinical report is to describe the rehabilitation of such a pediatric patient with severe PESS. The patient was successfully rehabilitated by presurgical conformer therapy, socket reconstruction surgery with non-meshed intermediate split thickness skin graft (STSG)/Blair-Brown graft, and postsurgical conformer stent. This was followed by fabrication of a custom ocular prosthesis, to achieve favorable functional, physical, and psychological effects. © 2014 by the American College of Prosthodontists.
8-year survivorship analysis and subjective results of 687 primary Balgrist hip sockets.
Echtler, B; Jacob, H A; Houweling, M; Hersche, O
1999-09-01
The Balgrist hip socket consists of an outer split ring in the form of a truncated cone, made of titanium, which is expanded by a tapered HDPE insert during implantation, thus ensuring firm primary press-fit and the possibility of retightening in the postoperative remodelling phase. Between November 1987 and October 1996, 687 primary Balgrist hip sockets were implanted in 555 patients. Five hundred and thirty-seven patients were investigated. Of these patients, 71.1% never had pain in the operated hip, 88.1% had no problems putting on their shoes, 76.2% were able to walk one or more hours. Furthermore, 91.7% are very or mostly content with the postoperative result. Nineteen hip sockets had to be revised until April 1997. With a 92.1% Kaplan-Meier survivorship rate after 8 years the Balgrist hip socket ranks among the most successful noncemented acetabular components.
Design of a 6-DOF upper limb rehabilitation exoskeleton with parallel actuated joints.
Chen, Yanyan; Li, Ge; Zhu, Yanhe; Zhao, Jie; Cai, Hegao
2014-01-01
In this paper, a 6-DOF wearable upper limb exoskeleton with parallel actuated joints which perfectly mimics human motions is proposed. The upper limb exoskeleton assists the movement of physically weak people. Compared with the existing upper limb exoskeletons which are mostly designed using a serial structure with large movement space but small stiffness and poor wearable ability, a prototype for motion assistance based on human anatomy structure has been developed in our design. Moreover, the design adopts balls instead of bearings to save space, which simplifies the structure and reduces the cost of the mechanism. The proposed design also employs deceleration processes to ensure that the transmission ratio of each joint is coincident.
The Interplay of Surface Mount Solder Joint Quality and Reliability of Low Volume SMAs
NASA Technical Reports Server (NTRS)
Ghaffarian, R.
1997-01-01
Spacecraft electronics including those used at the Jet Propulsion Laboratory (JPL), demand production of highly reliable assemblies. JPL has recently completed an extensive study, funded by NASA's code Q, of the interplay between manufacturing defects and reliability of ball grid array (BGA) and surface mount electronic components.
Development of socketed foundations for S3X5.7 posts.
DOT National Transportation Integrated Search
2015-04-01
The objective of this study was to develop a socketed foundation for use with the S3x5.7 (S76x8.5) weak : post. The design focused on cylindrical, reinforced concrete foundations with a steel tube placed in the center for : use as the socket. The fou...
Hawke, B.C.
1963-02-26
This patent relates to a releasable coupling connecting a control rod to a control rod drive. This remotely operable coupling mechanism can connect two elements which are laterally and angviarly misaligned, and provides a means for sensing the locked condition of the elements. The coupling utilizes a spherical bayonet joint which is locked against rotation by a ball detent lock. (AEC)
Alveolar socket healing: what can we learn?
Araújo, Mauricio G; Silva, Cléverson O; Misawa, Mônica; Sukekava, Flavia
2015-06-01
Tooth extraction induces a series of complex and integrated local changes within the investing hard and soft tissues. These local alterations arise in order to close the socket wound and to restore tissue homeostasis, and are referred to as '"socket healing". The aims of the present report were twofold: first, to describe the socket-healing process; and, second, to discuss what can be learned from the temporal sequence of healing events, in order to improve treatment outcomes. The socket-healing process may be divided into three sequential, and frequently overlapping, phases: inflammatory; proliferative; and modeling/remodeling. Several clinical and experimental studies have demonstrated that the socket-healing process promotes up to 50% reduction of the original ridge width, greater bone resorption at the buccal aspect than at the lingual/palatal counterpart and a larger amount of alveolar bone reduction in the molar region. In conclusion, tooth extraction, once a simple and straightforward surgical procedure, should be performed in the knowledge that ridge reduction will follow and that further clinical steps should be considered to compensate for this, when considering future options for tooth replacement. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Carbon nanotubes functionalized with sodium hyaluronate restore bone repair in diabetic rat sockets.
Sá, M A; Andrade, V B; Mendes, R M; Caliari, M V; Ladeira, L O; Silva, E E; Silva, G A B; Corrêa-Júnior, J D; Ferreira, A J
2013-07-01
We evaluated the effects of sodium hyaluronate (HY) and carbon nanotubes functionalized with HY (HY-CNT) on bone repair in the tooth sockets of diabetic rats. Diabetes was induced by streptozotocin (50 mg kg(-1) i.v.), and the sockets were divided into normal control, diabetic control, diabetic treated with HY (1%), and diabetic treated with HY-CNT (100 μg ml(-1)) groups. The sockets were analyzed according to the percentage of bone formation and the number of cell nuclei. The percentage of bone trabeculae was lower in diabetic control animals (11.16 ± 5.10% vs 41.92 ± 6.34% in normal animals) after 14 days. Treating diabetic animals with HY or HY-CNT significantly increased the percentage of neoformed trabeculae (HY: 29.43 ± 3.29%; HY-CNT: 36.90 ± 3.07%). Moreover, the sockets of diabetic animals had an increased number of cell nuclei and HY or HY-CNT reduced this parameter. Our results indicate that HY and HY-CNT restore bone repair in the tooth sockets of diabetic rats, suggesting that these biomaterials are potential adjuvant therapies for the management of diabetes. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Al-Fakih, Ebrahim A.; Abu Osman, Noor Azuan; Eshraghi, Arezoo; Adikan, Faisal Rafiq Mahamd
2013-01-01
This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ∼0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction. PMID:23941909
Al-Fakih, Ebrahim A; Osman, Noor Azuan Abu; Eshraghi, Arezoo; Adikan, Faisal Rafiq Mahamd
2013-08-12
This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.
Joint Service Aircrew Mask (JSAM) Rotary Wing (RW): MPU-5 Noise Attenuation Performance
2016-06-09
Swayne Ball Aerospace and Technologies Corp. Dayton, OH Hilary Gallagher Warfighter Interface Division Battlespace Acoustics Branch Wright... Acoustics Branch Battlespace Acoustics Branch Warfighter Interface Division //signed// WILLIAM E. RUSSELL Chief, Warfighter Interface...Directorate Warfighter Interface Division Battlespace Acoustics Branch Wright-Patterson AFB OH 45433 711 HPW/RHCB 11. SPONSOR
Joint Service Aircrew Mask (JSAM) - Strategic Aircraft (SA): Noise Attenuation Performance
2015-08-25
Billy Swayne Ball Aerospace and Technologies Corp. Dayton, OH Hilary Gallagher Warfighter Interface Division Battlespace Acoustics Branch...DISTRIBUTION STATEMENT. //signed// //signed// Hilary Gallagher Robert C. McKinley Work Unit Manager Chief, Battlespace Acoustics Branch...Battlespace Acoustics Branch Warfighter Interface Division //signed// William E. Russell, Chief Warfighter Interface Division Human
Bone implant sockets made using three different procedures: a stability study in dogs
Campo, Julián
2012-01-01
Objective: This study compared the effects of three different methods of preparing bone implant sockets (drilling, osteotomes, and piezoelectric device) on osseointegration using resonance frequency analysis (RFA). Study Design: An experimental prospective study was designed. Material and Methods: Ten adult beagle dogs were studied. After 5 weeks, 23 out of 28 initially placed implants in the iliac crest were evaluated, comparing these three different procedures of bone implant socket. Student’s t-test (paired, two-tailed) was used to reveal differences among the three groups at each time point (SPSS 16.0, IL, USA). Results: After a 5-week healing period, the implants placed in sockets that were made using an osteotome or piezoelectric device were slightly more stable than those made by drilling. Reduced mechanical and heat injury to the bone is beneficial for maintaining and improving stability during the critical early healing period. Conclusion: Using RFA, there was evidence of a slight increase in implant stability in the iliac crest after 5 weeks of healing when the implant socket was made using a piezoelectric device or expansion procedure as compare with the drilling method. Key words:Bone implant sockets, drilling, osteotomes, piezoelectric, resonance frequency analysis, stability. PMID:24558558
Piezoelectric Bimorphs' Characteristics as In-Socket Sensors for Transfemoral Amputees
El-Sayed, Amr M.; Hamzaid, Nur Azah; Osman, Noor Azuan Abu
2014-01-01
Alternative sensory systems for the development of prosthetic knees are being increasingly highlighted nowadays, due to the rapid advancements in the field of lower limb prosthetics. This study presents the use of piezoelectric bimorphs as in-socket sensors for transfemoral amputees. An Instron machine was used in the calibration procedure and the corresponding output data were further analyzed to determine the static and dynamic characteristics of the piezoelectric bimorph. The piezoelectric bimorph showed appropriate static operating range, repeatability, hysteresis, and frequency response for application in lower prosthesis, with a force range of 0–100 N. To further validate this finding, an experiment was conducted with a single transfemoral amputee subject to measure the stump/socket pressure using the piezoelectric bimorph embedded inside the socket. The results showed that a maximum interface pressure of about 27 kPa occurred at the anterior proximal site compared to the anterior distal and posterior sites, consistent with values published in other studies. This paper highlighted the capacity of piezoelectric bimorphs to perform as in-socket sensors for transfemoral amputees. However, further experiments are recommended to be conducted with different amputees with different socket types. PMID:25513823
Simulations of a Molecular Cloud experiment using CRASH
NASA Astrophysics Data System (ADS)
Trantham, Matthew; Keiter, Paul; Vandervort, Robert; Drake, R. Paul; Shvarts, Dov
2017-10-01
Recent laboratory experiments explore molecular cloud radiation hydrodynamics. The experiment irradiates a gold foil with a laser producing x-rays to drive the implosion or explosion of a foam ball. The CRASH code, an Eulerian code with block-adaptive mesh refinement, multigroup diffusive radiation transport, and electron heat conduction developed at the University of Michigan to design and analyze high-energy-density experiments, is used to perform a parameter search in order to identify optically thick, optically thin and transition regimes suitable for these experiments. Specific design issues addressed by the simulations are the x-ray drive temperature, foam density, distance from the x-ray source to the ball, as well as other complicating issues such as the positioning of the stalk holding the foam ball. We present the results of this study and show ways the simulations helped improve the quality of the experiment. This work is funded by the LLNL under subcontract B614207 and NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas, Grant Number DE-NA0002956.
Madan, Rohit; Mohan, Ranjana; Bains, Vivek K; Gupta, Vivek; Singh, G P; Madan, Mani
2014-01-01
The aim of this study was to evaluate the extraction socket healing and dimensional changes following alveolar ridge preservation using polylactide and polyglycolide (PLA-PGA) sponge. Fifteen patients were selected for alveolar socket preservation immediately following tooth extraction. Monoradicular maxillary and mandibular teeth were evaluated. The selected sockets had intact sockets walls with a minimum of 7 mm of residual alveolar bone height. The test sites were thoroughly debrided and grafted with PLA-PGA sponge, while the control sites underwent natural healing. Computed tomography (CT) measurements were taken at baseline and 6 months. After 6 months of healing, final CT measurements were performed, and trephine core biopsy specimens were obtained for histologic analysis. Implants were placed immediately after biopsy harvesting. All subjects completed the study, and all sites healed without adverse events and allowed for implant placement. The mean difference in socket height, width, and density after 6 months was statistically significantly higher in the test sites compared with control sites. Clinical measurement at the midbuccal site of the alveolar socket showed a mean loss of 2.45 ± 0.67 mm in the control group, compared with a mean gain of 1.28 ± 0.58 mm in the test group. All test sites showed minimal ridge alterations, and statistically significant differences were observed between the test and control sites with respect to bone composition and horizontal and vertical bone loss, indicating that PLA-PGA sponge is suitable for alveolar ridge preservation.
Bi, Xiaoping; Fan, Xianqun; Zhou, Huifang; Shi, Wodong; Xiao, Caiwen; Lin, Min; Li, Zhenkang
2011-05-01
Retinoblastoma is a common malignant intraocular tumor in childhood, and most patients require enucleation or exenteration even with irradiation. Severe anophthalmic orbits and atresic eye sockets are not rare. We conducted a retrospective study to evaluate the results of surgical management of reconstruction of severe anophthalmic orbits and atresic eye sockets with vascular anastomosed free dorsalis pedis flap transplantation. There were 5 patients (5 eyes) who underwent reconstructive surgery of severe anophthalmic orbits and atresic eye sockets after enucleation and irradiation of retinoblastoma in our hospital during the 3 years. All patients had enucleation and irradiation immediately after the retinoblastoma was diagnosed and had never worn artificial eyes because of the atresic eye sockets. Vascular anastomosed free dorsalis pedis flaps, whose dimensions were typically 6.5 × 5.5 cm(2), were transplanted to reconstruct the severe anophthalmic orbits and atresic eye sockets. The donor sites were covered by free abdominal skin flaps. All the vascular anastomosed free dorsalis pedis flaps were valid after more than 6 months of follow-up. And then all the 5 patients underwent secondary autogenous dermal fat implantation to augment the supraorbital area depression. After the 2-stage reconstruction surgery, the dimensions of the eye sockets were adequate, and all patients were able to wear their prosthesis and had a satisfactory cosmetic result. Implantation of alloplastic materials is not recommended because of insufficient blood supply of the irradiated orbital area.
Alveolar socket preservation with demineralised bovine bone mineral and a collagen matrix
2017-01-01
Purpose The aim of the present study was to evaluate the healing of post-extraction sockets following alveolar ridge preservation clinically, radiologically, and histologically. Methods Overall, 7 extraction sockets in 7 patients were grafted with demineralised bovine bone mineral and covered with a porcine-derived non-crosslinked collagen matrix (CM). Soft tissue healing was clinically evaluated on the basis of a specific healing index. Horizontal and vertical ridge dimensional changes were assessed clinically and radiographically at baseline and 6 months after implant placement. For histological and histomorphometric analysis, bone biopsies were harvested from the augmented sites during implant surgery 6 months after the socket preservation procedure. Results Clinically, healing proceeded uneventfully in all the sockets. A trend towards reduced horizontal and vertical socket dimensions was observed from baseline to the final examination. The mean width and height of resorption were 1.21 mm (P=0.005) and 0.46 mm (P=0.004), respectively. Histologically, residual xenograft particles (31.97%±3.52%) were surrounded by either newly formed bone (16.02%±7.06%) or connective tissue (50.67%±8.42%) without fibrous encapsulation. The CM underwent a physiological substitution process in favour of well-vascularised collagen-rich connective tissue. Conclusions Socket preservation using demineralised bovine bone mineral in combination with CM provided stable dimensional changes of the alveolar ridge associated with good re-epithelialisation of the soft tissues during a 6-month healing period. PMID:28861284
Evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin.
Baslarli, Ozgur; Tumer, Celal; Ugur, Omer; Vatankulu, Betul
2015-01-01
The aim of this study was to determine whether the use of platelet rich fibrin (PRF) improved the healing of extraction sockets. A total of 20 patients with bilateral soft tissue impacted mandibular third molars were included in this study. The left and right third molars were extracted during the same session. Subsequently, the PRF membrane was randomly administered to one of the extraction sockets, whereas the contralateral sockets were left without treatment. On postoperative 30. and 90. days, panoramic images and bone scintigrams were taken to evaluate the bone healing between PRF-treated and non-PRF-treated sockets. Also, periodontal evaluation was performed in the same control sessions. Dependent group t test for paired samples was used for statistical analysis. The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 30 and 90 days postoperatively. Radio-opacity that can show the bone healing on panoramic images were measured by Image J programme and they did not differ significantly. Also periodontal values did not differ significantly. PRF might not lead to enhanced bone healing in impacted mandibular third molar extraction sockets 30 and 90 days after surgery. It is thought that PRF has the potential characteristics of an autologous fibrin matrix and can accelerate the healing. To better understand the effects of PRF on healing, further research is warranted with larger sample sizes.
76 FR 56279 - Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-13
... to socket arcing at the Integrated Drive Generator (IDG) feeder cable pylon/nacelle interface connector. The fretting corrosion phenomenon was identified to be the root cause of the pin to socket arcing... products. The MCAI states: In service experience has shown a number of events of pin to socket arcing at...
Ida, Hirofumi; Fukuhara, Kazunobu; Kusubori, Seiji; Ishii, Motonobu
2011-09-01
Computer graphics of digital human models can be used to display human motions as visual stimuli. This study presents our technique for manipulating human motion with a forward kinematics calculation without violating anatomical constraints. A motion modulation of the upper extremity was conducted by proportionally modulating the anatomical joint angular velocity calculated by motion analysis. The effect of this manipulation was examined in a tennis situation--that is, the receiver's performance of predicting ball direction when viewing a digital model of the server's motion derived by modulating the angular velocities of the forearm or that of the elbow during the forward swing. The results showed that the faster the server's forearm pronated, the more the receiver's anticipation of the ball direction tended to the left side of the serve box. In contrast, the faster the server's elbow extended, the more the receiver's anticipation of the ball direction tended to the right. This suggests that tennis players are sensitive to the motion modulation of their opponent's racket-arm.
Oyama, Sakiko; Yu, Bing; Blackburn, J Troy; Padua, Darin A; Li, Li; Myers, Joseph B
2013-10-01
There is a growing number of pitching-related upper extremity injuries among young baseball pitchers; however, there is a lack of data on the identification of injury prevention strategies, particularly the prevention of injuries through the instruction/modification of technique. The identification of technical parameters that are associated with increased joint loading is needed. To investigate the effects of excessive contralateral trunk tilt, a common technique identifiable by video observation, on pitching biomechanics and performance in high school baseball pitchers. The hypothesis was that this strategy is associated with greater joint loading and poor pitching performance. Descriptive laboratory study; Level of evidence, 3. The 3-dimensional pitching biomechanics, ball speed, and frontal view of the pitching technique from 72 high school baseball pitchers were captured on video and analyzed. The videos were reviewed to determine if the pitcher's trunk was excessively contralaterally tilted at the instant of maximal shoulder external rotation by examining whether the side of the pitcher's head ipsilateral to the throwing limb deviated by more than a head width from a vertical line passing through the pitcher's stride foot ankle. Upper extremity kinetics and upper extremity/trunk kinematics between pitchers with and without excessive contralateral trunk tilt were compared using independent t tests. Compared with pitchers who did not demonstrate excessive contralateral trunk tilt, those with excessive contralateral trunk tilt pitched at a higher ball speed (mean, 32.6 ± 2.2 vs 31.1 ± 2.9 m/s, respectively; P = .019) and experienced a greater elbow proximal force (mean, 103.9 ± 12.7 vs 93.2 ± 13.9 %weight, respectively; P = .001), shoulder proximal force (mean, 104.8 ± 14.1 vs 94.3 ± 15.5 %weight, respectively; P = .004), elbow varus moment (mean, 4.29 ± 0.73 vs 3.84 ± 0.8 %height*weight, respectively; P = .017), and shoulder internal rotation moment (mean, 4.21 ± 0.71 vs 3.75 ± 0.78 %height*weight, respectively; P = .011). Pitchers with excessive contralateral trunk tilt demonstrated less upper torso flexion at stride foot contact, less upper torso rotation, and greater upper torso contralateral flexion at maximal shoulder external rotation and ball release (P < .05). Excessive contralateral trunk tilt is a strategy that is associated with higher ball speeds and increased joint loading. Pitching with excessive contralateral trunk tilt, which can be identified through screening of the pitching technique, is associated with a benefit in performance and increased joint loading. Future study is warranted to determine if this strategy should be encouraged or discouraged by baseball coaches.
Development of a Wearable Assist Robot for Walk Rehabilitation After Knee Arthroplasty Surgery
NASA Astrophysics Data System (ADS)
Terada, H.; Zhu, Y.; Horiguchi, K.; Nakamura, M.; Takahashi, R.
In Japan, it is popular that the disease knee joints will be replaced to artificial joints by surgery. And we have to assist so many patients for walk rehabilitation. So, the wearable assist robot has been developed. This robot includes the knee motion assist mechanism and the hip joint support mechanism. Especially, the knee motion assist mechanism consists of a non-circular gear and grooved cams. This mechanism rotates and slides simultaneously, which has two degree-of-freedom. Also, the hip joint support mechanism consists of a hip brace and a ball-joint. This mechanism can avoid motion constraints which are the internal or external rotation and the adduction or abduction. Then, the control algorithm, which considers an assisting timing for the walk rehabilitation, has been proposed. A sensing system of a walk state for this control system uses a heel contacts sensor and knee and hip joint rotation angle sensors. Also, the prototype robot has been tested. And it is confirmed that the assisting system is useful.
Su, Hao; Dickstein-Fischer, Laurie; Harrington, Kevin; Fu, Qiushi; Lu, Weina; Huang, Haibo; Cole, Gregory; Fischer, Gregory S
2010-01-01
This paper presents the development of new prismatic actuation approach and its application in human-safe humanoid head design. To reduce actuator output impedance and mitigate unexpected external shock, the prismatic actuation method uses cables to drive a piston with preloaded spring. By leveraging the advantages of parallel manipulator and cable-driven mechanism, the developed neck has a parallel manipulator embodiment with two cable-driven limbs embedded with preloaded springs and one passive limb. The eye mechanism is adapted for low-cost webcam with succinct "ball-in-socket" structure. Based on human head anatomy and biomimetics, the neck has 3 degree of freedom (DOF) motion: pan, tilt and one decoupled roll while each eye has independent pan and synchronous tilt motion (3 DOF eyes). A Kalman filter based face tracking algorithm is implemented to interact with the human. This neck and eye structure is translatable to other human-safe humanoid robots. The robot's appearance reflects a non-threatening image of a penguin, which can be translated into a possible therapeutic intervention for children with Autism Spectrum Disorders.
Design and Implementation of a Biomimetic Turtle Hydrofoil for an Autonomous Underwater Vehicle
Font, Davinia; Tresanchez, Marcel; Siegentahler, Cedric; Pallejà, Tomàs; Teixidó, Mercè; Pradalier, Cedric; Palacin, Jordi
2011-01-01
This paper presents the design and implementation of a turtle hydrofoil for an Autonomous Underwater Vehicle (AUV). The final design of the AUV must have navigation performance like a turtle, which has also been the biomimetic inspiration for the design of the hydrofoil and propulsion system. The hydrofoil design is based on a National Advisory Committee for Aeronautics (NACA) 0014 hydrodynamic profile. During the design stage, four different propulsion systems were compared in terms of propulsion path, compactness, sealing and required power. The final implementation is based on a ball-and-socket mechanism because it is very compact and provides three degrees of freedom (DoF) to the hydrofoil with very few restrictions on the propulsion path. The propulsion obtained with the final implementation of the hydrofoil has been empirically evaluated in a water channel comparing different motion strategies. The results obtained have confirmed that the proposed turtle hydrofoil controlled with a mechanism with three DoF generates can be used in the future implementation of the planned AUV. PMID:22247660
Ductile fracture mechanism of low-temperature In-48Sn alloy joint under high strain rate loading.
Kim, Jong-Woong; Jung, Seung-Boo
2012-04-01
The failure behaviors of In-48Sn solder ball joints under various strain rate loadings were investigated with both experimental and finite element modeling study. The bonding force of In-48Sn solder on an Ni plated Cu pad increased with increasing shear speed, mainly due to the high strain-rate sensitivity of the solder alloy. In contrast to the cases of Sn-based Pb-free solder joints, the transition of the fracture mode from a ductile mode to a brittle mode was not observed in this solder joint system due to the soft nature of the In-48Sn alloy. This result is discussed in terms of the relationship between the strain-rate of the solder alloy, the work-hardening effect and the resulting stress concentration at the interfacial regions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... with ceiling fan light kits that have medium screw base sockets shall conform to the requirements... testing pin-based fluorescent lamps packaged with ceiling fan light kits that have pin-based sockets shall... base sockets, measure the efficacy, expressed in lumens per watt, in accordance with the test...
Detection of Prosthetic Knee Movement Phases via In-Socket Sensors: A Feasibility Study
El-Sayed, Amr M.; Tan, Kenneth Y. S.; Abu Osman, Noor Azuan
2015-01-01
This paper presents an approach of identifying prosthetic knee movements through pattern recognition of mechanical responses at the internal socket's wall. A quadrilateral double socket was custom made and instrumented with two force sensing resistors (FSR) attached to specific anterior and posterior sites of the socket's wall. A second setup was established by attaching three piezoelectric sensors at the anterior distal, anterior proximal, and posterior sites. Gait cycle and locomotion movements such as stair ascent and sit to stand were adopted to characterize the validity of the technique. FSR and piezoelectric outputs were measured with reference to the knee angle during each phase. Piezoelectric sensors could identify the movement of midswing and terminal swing, pre-full standing, pull-up at gait, sit to stand, and stair ascent. In contrast, FSR could estimate the gait cycle stance and swing phases and identify the pre-full standing at sit to stand. FSR showed less variation during sit to stand and stair ascent to sensitively represent the different movement states. The study highlighted the capacity of using in-socket sensors for knee movement identification. In addition, it validated the efficacy of the system and warrants further investigation with more amputee subjects and different sockets types. PMID:25945365
ERIC Educational Resources Information Center
Spignesi, B.
This instructional package, one in a series of individualized instructional units on automotive steering and suspension, consists of a student guide and an instructor guide dealing with prealignment checks. Covered in the module are the following steps in a prealignment check: checking the ride height of a vehicle, checking the ball joints and the…
Chen, J; He, Y; Shan, C; Pan, Q; Li, M; Xia, D
2015-10-01
An osteogenic inducer (OI) consisting of dexamethasone, vitamin C, and β-sodium glycerophosphate has the capacity to induce bone formation in vitro. The aim of this study was to assess the efficacy of the application of this OI on extraction socket healing. The bilateral first mandibular premolars were extracted from 75 New Zealand rabbits. Gelatin sponges carrying OI were implanted into the sockets. Sockets undergoing implantation of gelatin sponges alone were also evaluated, as well as non-implantation sockets. Specimens from each group were evaluated radiographically, histologically, and histomorphometrically using haematoxylin-eosin staining. Results showed earlier new bone formation and higher bone quality and quantity in the OI group compared to the other groups, and the differences were significant at 2, 4, 8, and 12 weeks postoperative. The OI significantly reduced the absorption of alveolar bone in terms of height; however, changes in the width were not significantly different between the three groups (P>0.05). The OI was shown to have a positive effect on healing of the tooth extraction sockets, was inexpensive, and was convenient to use during the operational procedure; therefore this could represent a promising implant material for human clinical application. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
2017-10-01
AWARD NUMBER: W81XWH-16-1-0785 TITLE: Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function...2016 - 29 Sep 2017 4. TITLE AND SUBTITLE Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function 5a...discomfort. 2. KEYWORDS: Provide a brief list of keywords (limit to 20 words). Prosthesis, prosthesis fit, technology , skin problems, amputee
Mello, C C; Lemos, C A A; Verri, F R; Dos Santos, D M; Goiato, M C; Pellizzer, E P
2017-09-01
The aim of this systematic review and meta-analysis was to compare the survival rate of the implants and the peri-implant tissue changes associated with implants inserted in fresh extraction sockets and those inserted in healed sockets. This review has been registered at PROSPERO under the number CRD42016043309. A systematic search was conducted by two reviewers independently in the databases PubMed/MEDLINE, Embase, and the Cochrane Library using different search terms; articles published until November 2016 were searched for. The searches identified 30 eligible studies. A total of 3,049 implants were installed in a total of 1,435 patients with a mean age of 46.68 years and a minimum of 6 months of follow-up. The survival rate of delayed implants (98.38%) was significantly greater than immediate implants (95.21%) (p=.001). For the marginal bone loss (p=.32), implant stability quotients values (p=.44), and pocket probing depth (p=.94) there was no significant difference between the analysed groups. The immediate implants placed in fresh sockets should be performed with caution because of the significantly lower survival rates than delayed implants inserted in healed sockets. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Hefferman, Gerald M; Zhang, Fan; Nunnery, Michael J; Huang, He
2015-04-01
In recent years, there has been an increased interest in recording high-quality electromyographic signals from within the sockets of lower-limb amputees. However, successful recording presents major challenges to both researchers and clinicians. This article details and compares four prototypical integrated socket-sensor designs used to record electromyographic signals from within the sockets of transfemoral amputees. Four prototypical socket-sensor configurations were constructed and tested on a single transfemoral amputee asked to perform sitting/standing, stair ascent/descent, and level ground walking. The number of large-amplitude motion artifacts generated using each prototype was quantified, the amount of skin irritation documented, and the comfort level of each assembly subjectively assessed by the amputee subject. Of the four configurations tested, the combination of a suction socket with integrated wireless surface electrodes generated the lowest number of large-amplitude motion artifacts, the least visible skin irritation, and was judged to be most comfortable by the amputee subject. The collection of high-quality electromyographic signals from an amputee's residual limb while maximizing patient comfort holds substantial potential to enhance neuromuscular clinical assessment and as a method of intuitive control of powered lower-limb prostheses. © The International Society for Prosthetics and Orthotics 2014.
Relationship of biomechanical factors to baseball pitching velocity: within pitcher variation.
Stodden, David F; Fleisig, Glenn S; McLean, Scott P; Andrews, James R
2005-02-01
To reach the level of elite, most baseball pitchers need to consistently produce high ball velocity but avoid high joint loads at the shoulder and elbow that may lead to injury. This study examined the relationship between fastball velocity and variations in throwing mechanics within 19 baseball pitchers who were analyzed via 3-D high-speed motion analysis. Inclusion in the study required each one to demonstrate a variation in velocity of at least 1.8 m/s (range 1.8-3.5 m/s) during 6 to 10 fastball pitch trials. Three mixed model analyses were performed to assess the independent effects of 7 kinetic, 11 temporal, and 12 kinematic parameters on pitched ball velocity. Results indicated that elbow flexion torque, shoulder proximal force, and elbow proximal force were the only three kinetic parameters significantly associated with increased ball velocity. Two temporal parameters (increased time to max shoulder horizontal adduction and decreased time to max shoulder internal rotation) and three kinematic parameters (decreased shoulder horizontal adduction at foot contact, decreased shoulder abduction during acceleration, and increased trunk tilt forward at release) were significantly related to increased ball velocity. These results point to variations in an individual's throwing mechanics that relate to pitched ball velocity, and also suggest that pitchers should focus on consistent mechanics to produce consistently high fastball velocities. In addition, pitchers should strengthen shoulder and elbow musculature that resist distraction as well as improve trunk strength and flexibility to maximize pitching velocity and help prevent injury.
Effect of plasma rich in growth factors on alveolar osteitis
Haraji, Afshin; Lassemi, Eshagh; Motamedi, Mohammad Hosein Kalantar; Alavi, Maryam; Adibnejad, Saman
2012-01-01
Introduction: The high prevalence of dry socket or alveolar osteitis (AO) is of concern in surgical removal of third molars. The aim of the present study was to assess the preventive effect of plasma rich in growth factors (PRGF) on AO and also its effect on pain management and healing acceleration in third molar extraction sockets of high-risk patients. Materials and Methods: This split-mouth, double-blind clinical trial included 40 bilateral third molar extractions (80 sockets) with at least one identified risk factor for AO. PRGF was obtained from patient's own blood, based on manufacturer's instruction, and blindly placed in one of the two bilateral sockets (PRGF group; n = 20) of each patient. The contralateral socket was treated with a placebo (control group; n = 20). Samples were evaluated for AO and pain incidence on days 2, 3 and 4 and healing and infection on days 3 and 7. Data were analyzed in SPSS v16 using Wilcoxon test. Results: There was a significant difference in dry socket and pain incidence and healing rate between the two groups. Intensity of pain and occurrence of dry socket in the study group was lower than the controls. Also the healing rate was higher (P < 0.05) for the PRGF group. No sign of infection was seen in either group. Conclusion: The application of PRGF may significantly reduce the incidence of AO or its associated pain and may accelerate healing. The prophylactic use of PRGF following third molar extraction may be suggested especially in the patients at risk of AO. PMID:23251056
Cooper, Lyndon F; Reside, Glenn J; Raes, Filiep; Garriga, Joan Soliva; Tarrida, Luis Giner; Wiltfang, Jörg; Kern, Matthias; De Bruyn, Hugo
2014-01-01
This 5-year prospective multicenter study compared implant survival and success, peri-implant health and soft tissue responses, crestal bone level stability, and complication rates following immediate loading of single OsseoSpeed implants placed in anterior maxillary healed ridges or extraction sockets. Individuals requiring anterior tooth replacement with single implants were treated and immediately provisionalized. Definitive all-ceramic crowns were placed at 12 weeks. Implant survival, bone levels, soft tissue levels, and peri-implant health were monitored for 5 years. One hundred thirteen patients received implants in fresh sockets (55) and healed ridges (58). After 5 years, 45 and 49 patients remained for evaluation, respectively. During the first year, three implants failed in the extraction socket group (94.6% survival) and one implant failed in the healed ridge group (98.3% survival); this difference was not significant. No further implant failures were recorded. After 5 years, the interproximal crestal bone levels were located a mean of 0.43 ± 0.63 mm and 0.38 ± 0.62 mm from the reference points of implants in sockets and healed ridges (not a significant difference). In both groups, papillae increased over time and peri-implant mucosal zenith positions were stable from the time of definitive crown placement in sockets and healed ridges. Compared to flap surgery for implants in healed ridges, flapless surgery resulted in increased peri-implant mucosal tissue dimension (average, 0.78 ± 1.34 mm vs 0.19 ± 0.79 mm). After 5 years, the bone and soft tissue parameters that characterize implant success and contribute to dental implant esthetics were similar following the immediate provisionalization of implants in sockets and healed ridges. The overall tissue responses and reported implant survival support the immediate provisionalization of dental implants in situations involving healed ridges and, under ideal circumstances, extraction sockets.