ERIC Educational Resources Information Center
Collado, Anahi; Risco, Cristina M.; Banducci, Anne N.; Chen, Kevin W.; MacPherson, Laura; Lejuez, Carl W.
2017-01-01
Research indicates that White adolescents tend to engage in greater levels of risk behavior relative to Black adolescents. To better understand these differences, the current study examined real-time changes in risk-taking propensity (RTP). The study utilized the Balloon Analogue Risk Task-Youth Version (BART-Y), a well-validated real-time,…
Gabriel, Kara I; Williamson, Ashley
2010-12-01
Framing uncertain scenarios to emphasize potential positive or negative elements influences decision making and behavior. The current experiment investigated sex differences in framing effects on risk-taking propensity in a modified version of the Balloon Analogue Risk Task (BART). Male and female undergraduates completed questionnaires on sensation seeking, impulsiveness, and risk and benefit perception prior to viewing one of three framing conditions for the BART: (1) positively-framed instructions emphasizing the ability to earn money if balloons were inflated to large size; (2) negatively framed instructions emphasizing the possibility that money could be lost if balloons were inflated to bursting; and (3) completely framed instructions noting both possible outcomes. Results revealed correlations between BART performance and impulsiveness for both sexes. Compared to positive and complete framing, negatively framed instructions decreased balloon inflation time in women but not men, indicating sex differences in response to treatments designed to alter risk-taking behavior.
Schrag, Yann; Tremea, Alessandro; Lagger, Cyril; Ohana, Noé; Mohr, Christine
2016-01-01
Studies indicated that people behave less responsibly after exposure to information containing deterministic statements as compared to free will statements or neutral statements. Thus, deterministic primes should lead to enhanced risk-taking behavior. We tested this prediction in two studies with healthy participants. In experiment 1, we tested 144 students (24 men) in the laboratory using the Iowa Gambling Task. In experiment 2, we tested 274 participants (104 men) online using the Balloon Analogue Risk Task. In the Iowa Gambling Task, the free will priming condition resulted in more risky decisions than both the deterministic and neutral priming conditions. We observed no priming effects on risk-taking behavior in the Balloon Analogue Risk Task. To explain these unpredicted findings, we consider the somatic marker hypothesis, a gain frequency approach as well as attention to gains and / or inattention to losses. In addition, we highlight the necessity to consider both pro free will and deterministic priming conditions in future studies. Importantly, our and previous results indicate that the effects of pro free will and deterministic priming do not oppose each other on a frequently assumed continuum. PMID:27018854
Schrag, Yann; Tremea, Alessandro; Lagger, Cyril; Ohana, Noé; Mohr, Christine
2016-01-01
Studies indicated that people behave less responsibly after exposure to information containing deterministic statements as compared to free will statements or neutral statements. Thus, deterministic primes should lead to enhanced risk-taking behavior. We tested this prediction in two studies with healthy participants. In experiment 1, we tested 144 students (24 men) in the laboratory using the Iowa Gambling Task. In experiment 2, we tested 274 participants (104 men) online using the Balloon Analogue Risk Task. In the Iowa Gambling Task, the free will priming condition resulted in more risky decisions than both the deterministic and neutral priming conditions. We observed no priming effects on risk-taking behavior in the Balloon Analogue Risk Task. To explain these unpredicted findings, we consider the somatic marker hypothesis, a gain frequency approach as well as attention to gains and / or inattention to losses. In addition, we highlight the necessity to consider both pro free will and deterministic priming conditions in future studies. Importantly, our and previous results indicate that the effects of pro free will and deterministic priming do not oppose each other on a frequently assumed continuum.
Fukunaga, Rena; Brown, Joshua W.; Bogg, Tim
2012-01-01
The inferior frontal gyrus/anterior insula (IFG/AI) and anterior cingulate cortex (ACC) are key regions involved in risk appraisal during decision making, but accounts of how these regions contribute to decision-making under risk remain contested. To help clarify the roles of these and other related regions, we used a modified version of the Balloon Analogue Risk Task (Lejuez et al., 2002) to distinguish between decision-making and feedback-related processes when participants decided to pursue a gain as the probability of loss increased parametrically. Specifically, we set out to test whether ACC and IFG/AI regions correspond to loss-aversion at the time of decision making in a way that is not confounded with either reward-seeking or infrequency effects. When participants chose to discontinue inflating the balloon (win option), we observed greater ACC and mainly bilateral IFG/AI activity at the time of decision as the probability of explosion increased, consistent with increased loss-aversion but inconsistent with an infrequency effect. In contrast, we found robust vmPFC activity when participants chose to continue inflating the balloon (risky option), consistent with reward-seeking. However, in the cingulate and mainly bilateral IFG regions, BOLD activation decreased when participants chose to inflate the balloon as the probability of explosion increased, findings consistent with a reduced loss-aversion signal. Our results highlight the existence of distinct reward-seeking and loss-averse signals during decision-making, as well as the importance of distinguishing decision and feedback signals. PMID:22707378
Emotion regulation and decision making under risk and uncertainty.
Heilman, Renata M; Crişan, Liviu G; Houser, Daniel; Miclea, Mircea; Miu, Andrei C
2010-04-01
It is well established that emotion plays a key role in human social and economic decision making. The recent literature on emotion regulation (ER), however, highlights that humans typically make efforts to control emotion experiences. This leaves open the possibility that decision effects previously attributed to acute emotion may be a consequence of acute ER strategies such as cognitive reappraisal and expressive suppression. In Study 1, we manipulated ER of laboratory-induced fear and disgust, and found that the cognitive reappraisal of these negative emotions promotes risky decisions (reduces risk aversion) in the Balloon Analogue Risk Task and is associated with increased performance in the prehunch/hunch period of the Iowa Gambling Task. In Study 2, we found that naturally occurring negative emotions also increase risk aversion in Balloon Analogue Risk Task, but the incidental use of cognitive reappraisal of emotions impedes this effect. We offer evidence that the increased effectiveness of cognitive reappraisal in reducing the experience of emotions underlies its beneficial effects on decision making. Copyright 2010 APA, all rights reserved.
Fukunaga, Rena; Brown, Joshua W; Bogg, Tim
2012-09-01
The inferior frontal gyrus/anterior insula (IFG/AI) and anterior cingulate cortex (ACC) are key regions involved in risk appraisal during decision making, but accounts of how these regions contribute to decision making under risk remain contested. To help clarify the roles of these and other related regions, we used a modified version of the Balloon Analogue Risk Task (Lejuez et al., Journal of Experimental Psychology: Applied, 8, 75-84, 2002) to distinguish between decision-making and feedback-related processes when participants decided to pursue a gain as the probability of loss increased parametrically. Specifically, we set out to test whether the ACC and IFG/AI regions correspond to loss aversion at the time of decision making in a way that is not confounded with either reward-seeking or infrequency effects. When participants chose to discontinue inflating the balloon (win option), we observed greater ACC and mainly bilateral IFG/AI activity at the time of decision as the probability of explosion increased, consistent with increased loss aversion but inconsistent with an infrequency effect. In contrast, we found robust vmPFC activity when participants chose to continue inflating the balloon (risky option), consistent with reward seeking. However, in the cingulate and in mainly bilateral IFG regions, blood-oxygenation-level-dependent activation decreased when participants chose to inflate the balloon as the probability of explosion increased, findings that are consistent with a reduced loss aversion signal. Our results highlight the existence of distinct reward-seeking and loss-averse signals during decision making, as well as the importance of distinguishing between decision and feedback signals.
Buelow, Melissa T; Barnhart, Wesley R
2017-01-01
Multiple studies have shown that performance on behavioral decision-making tasks, such as the Iowa Gambling Task (IGT) and Balloon Analogue Risk Task (BART), is influenced by external factors, such as mood. However, the research regarding the influence of worry is mixed, and no research has examined the effect of math or test anxiety on these tasks. The present study investigated the effects of anxiety (including math anxiety) and math performance on the IGT and BART in a sample of 137 undergraduate students. Math performance and worry were not correlated with performance on the IGT, and no variables were correlated with BART performance. Linear regressions indicated math anxiety, physiological anxiety, social concerns/stress, and test anxiety significantly predicted disadvantageous selections on the IGT during the transition from decision making under ambiguity to decision making under risk. Implications for clinical evaluation of decision making are discussed. © The Author(s) 2015.
Neural Correlates of Traditional Chinese Medicine Induced Advantageous Risk-Taking Decision Making
ERIC Educational Resources Information Center
Lee, Tiffany M. Y.; Guo, Li-guo; Shi, Hong-zhi; Li, Yong-zhi; Luo, Yue-jia; Sung, Connie Y. Y.; Chan, Chetwyn C. H.; Lee, Tatia M. C.
2009-01-01
This fMRI study examined the neural correlates of the observed improvement in advantageous risk-taking behavior, as measured by the number of adjusted pumps in the Balloon Analogue Risk Task (BART), following a 60-day course of a Traditional Chinese Medicine (TCM) recipe, specifically designed to regulate impulsiveness in order to modulate…
ERIC Educational Resources Information Center
de Boer, Anouk; Peeters, Margot; Koning, Ina
2017-01-01
In this experimental study, it was examined to what extent peers and sex were important predictors of risk taking behavior of adolescents. Participants were 140 Dutch adolescents (52.9% boys, 12-15 years) who completed the Balloon Analogue Risk Task (BART) as a measure of risk taking behavior, either individually or in the presence of homogenous…
Ashenhurst, James R; Bujarski, Spencer; Jentsch, J David; Ray, Lara A
2014-08-01
The relationship between risk-taking behavior and substance dependence has proven to be complex, particularly when examining across participants expressing a range of substance use problem severity. While main indices of risk-taking in the Balloon Analogue Risk Task (BART) positively associate with problematic alcohol use in adolescent populations (e.g., MacPherson, Magidson, Reynolds, Kahler, & Lejuez, 2010), several studies have observed a negative relationship when examining behavior within adult substance using populations (Ashenhurst, Jentsch, & Ray, 2011; Campbell, Samartgis, & Crowe, 2013). To examine potential mechanisms that underlie this negative relationship, we implemented multilevel regression models on trial-by-trial BART data gathered from 295 adult problem drinkers. These models accounted for participant behavior on trials following balloon bursts or cash outs as indices of loss and reward reactivity, respectively, and included control variables including age, IQ, and individual delay discounting rate. Results revealed that individual trial pumping was significantly predicted by trial number, and by whether or not the previous trial was a big burst or a big cash out (i.e., large magnitude of potential gains) in a manner consistent with a "near-miss" effect. Furthermore, severity of alcohol problems moderated the effect of a previous trial big burst, but not of a big cash out, on subsequent trial behavior such that those with greater severity demonstrated relative insensitivity to this "near-miss" effect. These results extend previous studies suggesting that alcohol abusers are less risky on the BART by specifying a mechanism underlying this pattern, namely, diminished reactivity to large magnitude losses.
Frontal theta accounts for individual differences in the cost of conflict on decision making.
Pinner, John F L; Cavanagh, James F
2017-10-01
Cognitive conflict is often experienced as a difficult, frustrating, and aversive state. Recent studies have indicated that conflict acts as an implicit cost during learning, valuation, and the instantiation of cognitive control. Here we investigated if an implicit manipulation of conflict also influences explicit decision making to risk. Participants were required to perform a Balloon Analogue Risk Task wherein the virtual balloon was inflated by performing a flankers task. By varying the percent of incongruent flanker trials between balloons, we hypothesized that participants would pump the balloon fewer times in conditions of higher conflict and that frontal midline theta would account for significant variance in this relationship. Across two studies, we demonstrate that conflict did not elicit reliable behavioral changes in this task across participants. However, individual differences in frontal theta power accounted for significant variance by predicting diminished balloon pumps. Thus, while conflict costs may act as investments to some individuals (invigorating behavior), it is aversive to others (diminishing behavior), and frontal midline theta power accounts for these varying behavioral tendencies between individuals. These findings demonstrate how frontal midline theta is not only a candidate mechanism for implementing cognitive control, but it is sensitive to the inherent costs therein. Copyright © 2017 Elsevier B.V. All rights reserved.
Guo, Heng; Zhang, Zhuoran; Da, Shu; Sheng, Xiaotian; Zhang, Xichao
2018-02-01
Studies on risk preferences have long been of great concern and have examined the neural basis underlying risk-based decision making. However, studies using conventional transcranial direct current stimulation (tDCS) revealed that bilateral stimulation could change risk propensity with limited evidence of precisely focalized unilateral high-definition transcranial direct current stimulation (HD-tDCS). The aim of this experiment was to investigate the effect of HD-tDCS focalizing the left dorsal lateral prefrontal cortex (DLPFC) on risk-taking behavior during the Balloon Analogue Risk Task (BART). This study was designed as a between-subject, single-blind, sham-controlled experiment. University students were randomly assigned to three groups: the anodal group (F3 anode, AF3, F1, F5, FC3 returned), the cathodal group (F3 cathodal, AF3, F1, F5, FC3 returned) and the sham group. Subsequently, 1.5-mA 20-min HD-tDCS was applied during the BART, and the Positive Affect and Negative Affect Scale (PANAS), the Sensation Seeking Scale-5 (SSS-5), and the Behavioral Inhibition System and Behavioral Approach System scale (BIS/BAS) were measured as control variables. The cathodal group earned less total money than the sham group, and no significant difference was observed between the anodal group and the sham group. These results showed that, to some extent, focalized unilateral cathodal HD-tDCS on left DLPFC could change performance during risky tasks and diminish risky decision making. Further studies are needed to investigate the dose effect and electrode distribution of HD-tDCS during risky tasks and examine synchronous brain activity to show the neural basis.
Mind the Gap: Bridging economic and naturalistic risk-taking with cognitive neuroscience
Schonberg, Tom; Fox, Craig R.; Poldrack, Russell A.
2010-01-01
Economists define risk in terms of variability of possible outcomes whereas clinicians and laypeople generally view risk as exposure to possible loss or harm. Neuroeconomic studies using relatively simple behavioral tasks have identified a network of brain regions that respond to economic risk, but these studies have had limited success predicting naturalistic risk-taking. In contrast, more complex behavioral tasks developed by clinicians (e.g., Balloon Analogue Risk Task and Iowa Gambling Task) correlate with naturalistic risk-taking but resist decomposition into distinct cognitive constructs. We propose that to bridge this gap and better understand neural substrates of naturalistic risk-taking, new tasks are needed that: (1) are decomposable into basic cognitive/economic constructs; (2) predict naturalistic risk-taking; and (3) engender dynamic, affective engagement. PMID:21130018
Mind the gap: bridging economic and naturalistic risk-taking with cognitive neuroscience.
Schonberg, Tom; Fox, Craig R; Poldrack, Russell A
2011-01-01
Economists define risk in terms of the variability of possible outcomes, whereas clinicians and laypeople generally view risk as exposure to possible loss or harm. Neuroeconomic studies using relatively simple behavioral tasks have identified a network of brain regions that respond to economic risk, but these studies have had limited success predicting naturalistic risk-taking. By contrast, more complex behavioral tasks developed by clinicians (e.g. Balloon Analogue Risk Task and Iowa Gambling Task) correlate with naturalistic risk-taking but resist decomposition into distinct cognitive constructs. We propose here that to bridge this gap and better understand neural substrates of naturalistic risk-taking, new tasks are needed that: are decomposable into basic cognitive and/or economic constructs; predict naturalistic risk-taking; and engender dynamic, affective engagement. Copyright © 2010 Elsevier Ltd. All rights reserved.
Effects of acute and chronic caffeine on risk-taking behavior in children and adolescents.
Temple, Jennifer L; Ziegler, Amanda M; Graczyk, Adam M; Crandall, Amanda
2017-05-01
Consumption of caffeinated beverages is associated with increased risk-taking behavior. The purpose of this study was to determine if acute caffeine administration influences risk-taking behavior in a dose-dependent manner. Participants were pre- (ages 8-9) and post-pubertal (ages 15-17) children who visited the laboratory three times and consumed a beverage containing 0, 1, or 2 mg/kg of caffeine. Thirty minutes later, participants completed the balloon analogue risk task (BART), the Iowa gambling task (IGT), and a delay discounting task. The number of balloons exploded on the BART task was significantly increased after 2 mg/kg of caffeine in moderate caffeine consumers, but was decreased after 2 mg/kg of caffeine in high caffeine consumers. There were no main effects of caffeine dose on the delay discounting task or on the IGT. Post-pubertal participants showed reduced delay discounting compared with pre-pubertal participants. Finally, average daily caffeine use was significantly, positively correlated with scores on a risk-taking questionnaire. These data suggest that caffeine dose-dependently influences decision making and risk taking. More research is needed to determine the mechanism of this difference as well as the extent to which sex and pubertal phase influence these relationships.
A simple analogue of lung mechanics.
Sherman, T F
1993-12-01
A model of the chest and lungs can be easily constructed from a bottle of water, a balloon, a syringe, a rubber stopper, glass and rubber tubing, and clamps. The model is a more exact analogue of the body than the classic apparatus of Hering in two respects: 1) the pleurae and intrapleural fluid are represented by water rather than air, and 2) the subatmospheric "intrapleural" pressure is created by the elasticity of the "lung" (balloon) rather than by a vacuum pump. With this model, students can readily see how the lung is inflated and deflated by movements of the "diaphragm and chest" (syringe plunger) and how intrapleural pressures change as this is accomplished.
Greater Risk-Sensitivity of Dorsolateral Prefrontal Cortex in Young Smokers than in Nonsmokers
Galván, Adriana; Schonberg, Tom; Mumford, Jeanette; Kohno, Milky; Poldrack, Russell A.; London, Edythe D.
2013-01-01
Rationale Despite a national reduction in the prevalence of cigarette smoking, ~19% of the adult U.S. population persists in this behavior, with the highest prevalence among 18–25-year-olds. Given that the choice to smoke imposes a known health risk, clarification of brain function related to decision-making, particularly involving risk-taking, in smokers may inform prevention and smoking cessation strategies. Objectives This study aimed to compare brain function related to decision-making in young smokers and nonsmokers. Methods The Balloon Analogue Risk Task (BART) is a computerized risky decision-making task in which participants pump virtual balloons, each pump associated with an incremental increase in potential payoff on a given trial but also with greater risk of balloon explosion and loss of payoff. We used this task to compare brain activation associated with risky decision-making in smokers (n=18) and nonsmokers (n=25) while they performed the BART during functional magnetic resonance imaging (fMRI). The participants were young men and women, 17–21 years of age. Results Risk level (number of pumps) modulated brain activation in the right dorsolateral and ventrolateral prefrontal cortices more in smokers than in nonsmokers; and smoking severity (Heaviness of Smoking Index) was positively related to this modulation in an adjacent frontal region. Conclusions Given evidence for involvement of the right dorsolateral and ventrolateral prefrontal cortices in inhibitory control, these findings suggest that young smokers have a different contribution of prefrontal cortical substrates to risky decision-making than nonsmokers. Future studies are warranted to determine whether the observed neurobiological differences precede or result from smoking. PMID:23644912
Negative Affect, Decision Making, and Attentional Networks.
Ortega, Ana Raquel; Ramírez, Encarnación; Colmenero, José María; García-Viedma, Ma Del Rosario
2017-02-01
This study focuses on whether risk avoidance in decision making depends on negative affect or it is specific to anxious individuals. The Balloon Analogue Risk Task was used to obtain an objective measure in a risk situation with anxious, depressive, and control individuals. The role of attentional networks was also studied using the Attentional Network Test-Interaction (ANT-I) task with neutral stimuli. A significant difference was observed between anxious and depressive individuals in assumed risk in decision making. We found no differences between anxious and normal individuals in the alert, orientation, and congruency effects obtained in the ANT-I task. The results showed that there was no significant relationship between the risk avoidance and the indexes of alertness, orienting, and control. Future research shall determine whether emotionally relevant stimulation leads to attentional control deficit or whether differences between anxious and no anxious individuals are due to the type of strategy followed in choice tasks.
Outcome Probability versus Magnitude: When Waiting Benefits One at the Cost of the Other
Young, Michael E.; Webb, Tara L.; Rung, Jillian M.; McCoy, Anthony W.
2014-01-01
Using a continuous impulsivity and risk platform (CIRP) that was constructed using a video game engine, choice was assessed under conditions in which waiting produced a continuously increasing probability of an outcome with a continuously decreasing magnitude (Experiment 1) or a continuously increasing magnitude of an outcome with a continuously decreasing probability (Experiment 2). Performance in both experiments reflected a greater desire for a higher probability even though the corresponding wait times produced substantive decreases in overall performance. These tendencies are considered to principally reflect hyperbolic discounting of probability, power discounting of magnitude, and the mathematical consequences of different response rates. Behavior in the CIRP is compared and contrasted with that in the Balloon Analogue Risk Task (BART). PMID:24892657
Emotional intelligence, risk perception in abstinent cocaine dependent individuals.
Romero-Ayuso, Dulce; Mayoral-Gontán, Yolanda; Triviño-Juárez, José-Matías
2016-01-01
Cocaine is now responsible for the second-highest number of cessation intervention requests. In this study we analyze the different skills of emotional intelligence in cocaine- dependent patients maintaining abstinence. The Mayer- Salovey-Caruso Emotional Intelligence Test (MSCEIT) and the Balloon Analogue Risk Task (BART) were administered to 50 subjects (25 individuals with no history of drug use and 25 individuals in treatment at the Addictive Behaviors Unit in a state of withdrawal at the time of evaluation). The results showed differences between these groups in overall emotional intelligence quotient, strategic emotional intelligence, understanding emotions and emotional management. Cocaine-addicted participants showed difficulties in analyzing complex emotions and regulating their emotional response, aspects that can interfere with interactions in daily life.
Bonini, Nicolao; Grecucci, Alessandro; Nicolè, Manuel; Savadori, Lucia
2018-06-01
A group of pathological gamblers and a group of problem gamblers (i.e., gamblers at risk of becoming pathological) were compared to healthy controls on their risk-taking propensity after prior losses. Each participant played both the Balloon Analogue Risk Taking task (BART) and a modified version of the same task, where individuals face five repeated predetermined early losses at the onset of the game. No significant difference in risk-taking was found between groups on the standard BART task, while significant differences emerged when comparing behaviors in the two tasks: both pathological gamblers and controls reduced their risk-taking tendency after prior losses in the modified BART compared to the standard BART, whereas problem gamblers showed no reduction in risk-taking after prior losses. We interpret these results as a sign of a reduced sensitivity to negative feedback in problem gamblers which might contribute to explain their loss-chasing tendency.
Augsburger, Mareike; Elbert, Thomas
2017-01-01
Exposure to traumatic stressors and subsequent trauma-related mental changes may alter a person's risk-taking behavior. It is unclear whether this relationship depends on the specific types of traumatic experiences. Moreover, the association has never been tested in displaced individuals with substantial levels of traumatic experiences. The present study assessed risk-taking behavior in 56 displaced individuals by means of the balloon analogue risk task (BART). Exposure to traumatic events, symptoms of posttraumatic stress disorder and depression were assessed by means of semi-structured interviews. Using a novel statistical approach (stochastic gradient boosting machines), we analyzed predictors of risk-taking behavior. Exposure to organized violence was associated with less risk-taking, as indicated by fewer adjusted pumps in the BART, as was the reported experience of physical abuse and neglect, emotional abuse, and peer violence in childhood. However, civil traumatic stressors, as well as other events during childhood were associated with lower risk taking. This suggests that the association between global risk-taking behavior and exposure to traumatic stress depends on the particular type of the stressors that have been experienced.
Fasting and meal-induced CCK and PP secretion following intragastric balloon treatment for obesity.
Mathus-Vliegen, Elisabeth M H; de Groot, Gerrit H
2013-05-01
Satiety is centrally and peripherally mediated by gastrointestinal peptides and the vagal nerve. We aimed to investigate whether intragastric balloon treatment affects satiety through effects on fasting and meal-stimulated cholecystokinin (CCK) and pancreatic polypeptide (PP) secretion. Patients referred for obesity treatment were randomised to 13 weeks of sham treatment followed by 13 weeks of balloon treatment (group 1; sham/balloon) or to twice a 13-week period of balloon treatment (group 2; balloon/balloon). Blood samples were taken for fasting and meal-stimulated CCK and PP levels at the start (T0) and after 13 (T1) and 26 (T2) weeks. Patients filled out visual analogue scales (VAS) to assess satiety. Forty-two patients (35 females, body weight 125.1 kg, BMI 43.3 kg/m(2)) participated. In group 1, basal CCK levels decreased but meal-stimulated response remained unchanged after 13 weeks of sham treatment. In group 2, basal and meal-stimulated CCK levels decreased after 13 weeks of balloon treatment. At the end of the second 13-week period, when group 1 had their first balloon treatment, they duplicated the initial 13-week results of group 2, whereas group 2 continued their balloon treatment and reduced meal-stimulated CCK release. Both groups showed reduced meal-stimulated PP secretions at T1 and T2 compared to T0. Changes in diet composition and VAS scores were similar. Improvements in glucose homeostasis partly explained the PP results. The reduced CCK and PP secretion after balloon positioning was unexpected and may reflect delayed gastric emptying induced by the balloon. Improved glucose metabolism partly explained the reduced PP secretion. Satiety and weight loss were not adversely influenced by these hormonal changes.
Poder, Thomas G; Fisette, Jean-François
2016-07-01
To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.
Paydary, Koosha; Mahin Torabi, Somayeh; SeyedAlinaghi, SeyedAhmad; Noori, Mehri; Noroozi, Alireza; Ameri, Sara; Ekhtiari, Hamed
2016-01-01
Objective. The aim of this study was to compare impulsivity and risky decision making among HIV-positive and negative heroin dependent persons. Methods. We compared different dimensions of impulsivity and risky decision making in two groups of 60 HIV-positive and 60 HIV-negative male heroin dependent persons. Each group was comprised of equal numbers of current (treatment seeker) and former (abstinent) heroin addicts. Data collection tools included Balloon Analogue Risk Task (BART), Iowa Gambling Task (IGT), Barratt Impulsiveness Scale (BIS), and Zuckerman Sensation Seeking Scale (SSS). Results. In SSS, comprised of four subscales including thrill and adventure seeking (TAS), experience seeking (ES), disinhibition (DIS), and boredom susceptibility (BS), there was a borderline difference in DIS (P = 0.08) as HIV-positive group scored higher than HIV-negative group. Also, ES and total score were significantly higher among HIV-positive patients. In BART, HIV-positive subjects scored higher in risk taking than HIV-negative subjects as reflected in higher Average Number of puffs in Successful Balloons (ANSB). In BIS, HIV-positive group scored significantly higher in cognitive impulsivity (CI) (P = 0.03) and nonplanning impulsivity (NPI) (P = 0.05) in comparison to HIV-negative group. Also, current heroin addicts scored significantly higher in NPI compared to former addict HIV-negative participants (P = 0.015). IGT did not show any significant difference between groups. Conclusion. Higher levels of impulsivity and risk taking behaviors among HIV-positive heroin addicts will increase serious concerns regarding HIV transmission from this group to other opiate dependents and healthy people. PMID:27051528
Pletzer, Belinda; M Ortner, Tuulia
2016-09-01
Personality assessment has been challenged by the fact that different assessment methods (implicit measures, behavioral measures and explicit rating scales) show little or no convergence in behavioral studies. In this neuroimaging study we address for the first time, whether different assessment methods rely on separate or overlapping neuronal systems. Fifty nine healthy adult participants completed two objective personality tests of risk propensity: the more implicit Balloon Analogue Risk Task (BART) and the more explicit Game of Dice Task (GDT). Significant differences in activation, as well as connectivity patterns between both tasks were observed. In both tasks, risky decisions yielded significantly stronger activations than safe decisions in the bilateral caudate, as well as the bilateral Insula. The finding of overlapping brain areas validates different assessment methods, despite their behavioral non-convergence. This suggests that neuroimaging can be an important tool of validation in the field of personality assessment. Copyright © 2016 Elsevier B.V. All rights reserved.
Real and hypothetical monetary rewards modulate risk taking in the brain.
Xu, Sihua; Pan, Yu; Wang, You; Spaeth, Andrea M; Qu, Zhe; Rao, Hengyi
2016-07-07
Both real and hypothetical monetary rewards are widely used as reinforcers in risk taking and decision making studies. However, whether real and hypothetical monetary rewards modulate risk taking and decision making in the same manner remains controversial. In this study, we used event-related potentials (ERP) with a balloon analogue risk task (BART) paradigm to examine the effects of real and hypothetical monetary rewards on risk taking in the brain. Behavioral data showed reduced risk taking after negative feedback (money loss) during the BART with real rewards compared to those with hypothetical rewards, suggesting increased loss aversion with real monetary rewards. The ERP data demonstrated a larger feedback-related negativity (FRN) in response to money loss during risk taking with real rewards compared to those with hypothetical rewards, which may reflect greater prediction error or regret emotion after real monetary losses. These findings demonstrate differential effects of real versus hypothetical monetary rewards on risk taking behavior and brain activity, suggesting a caution when drawing conclusions about real choices from hypothetical studies of intended behavior, especially when large rewards are used. The results have implications for future utility of real and hypothetical monetary rewards in studies of risk taking and decision making.
Augsburger, Mareike; Elbert, Thomas
2017-01-01
Exposure to traumatic stressors and subsequent trauma-related mental changes may alter a person’s risk-taking behavior. It is unclear whether this relationship depends on the specific types of traumatic experiences. Moreover, the association has never been tested in displaced individuals with substantial levels of traumatic experiences. The present study assessed risk-taking behavior in 56 displaced individuals by means of the balloon analogue risk task (BART). Exposure to traumatic events, symptoms of posttraumatic stress disorder and depression were assessed by means of semi-structured interviews. Using a novel statistical approach (stochastic gradient boosting machines), we analyzed predictors of risk-taking behavior. Exposure to organized violence was associated with less risk-taking, as indicated by fewer adjusted pumps in the BART, as was the reported experience of physical abuse and neglect, emotional abuse, and peer violence in childhood. However, civil traumatic stressors, as well as other events during childhood were associated with lower risk taking. This suggests that the association between global risk-taking behavior and exposure to traumatic stress depends on the particular type of the stressors that have been experienced. PMID:28498865
Auditory Risk of Exploding Hydrogen-Oxygen Balloons
ERIC Educational Resources Information Center
Gee, Kent L.; Vernon, Julia A.; Macedone, Jeffrey H.
2010-01-01
Although hydrogen-oxygen balloon explosions are popular demonstrations, the acoustic impulse created poses a hearing damage risk if the peak level exceeds 140 dB at the listener's ear. The results of acoustical measurements of hydrogen-oxygen balloons of varying volume and oxygen content are described. It is shown that hydrogen balloons may be…
Ryan, Katherine K.; Dube, Sarahjane L.; Potter, Alexandra S.
2012-01-01
Beneficial effects of nicotine on cognition and behavioral control are hypothesized to relate to the high rates of cigarette smoking in Attention-Deficit/Hyperactivity Disorder (ADHD). Given that ADHD is associated with both impulsivity and elevated risk taking, we hypothesized that nicotine modulates risk taking, as it does impulsivity. 26 non-smoking young adults (15 controls with normal impulsivity and 11 ADHD with high impulsivity) received 7 mg transdermal nicotine, 20 mg oral mecamylamine, and placebo on separate days, followed by the Balloon Analogue Risk Task (BART). Statistical analyses found no group differences in baseline risk taking. Reexamination of the data using a median split on baseline risk taking, to create high (HRT) and low (LRT) risk taking groups, revealed significant effects of nicotinic drugs that differed by group. Nicotine reduced risk taking in HRT and mecamylamine increased risk taking in LRT. This finding supports the hypothesis that nicotinic receptor function modulates risk taking broadly, beyond those with ADHD, and is consistent with rate dependent cholinergic modulation of other cognitive functions. Further, the results demonstrate that high impulsivity is separable from high risk taking in young adults with ADHD, supporting the utility of these differential behavioral phenotypes for neurobiological studies. PMID:23159875
The Risky Business of Dopamine Agonists in Parkinson Disease and Impulse Control Disorders
Claassen, Daniel O.; van den Wildenberg, Wery P.M.; Ridderinkhof, K. Richard; Jessup, Charles K.; Harrison, Madaline B.; Wooten, G. Frederick; Wylie, Scott A.
2011-01-01
Risk-taking behavior is characterized by pursuit of reward in spite of potential negative consequences. Dopamine neurotransmission along the mesocorticolimbic pathway is a potential modulator of risk behavior. In patients with Parkinson's Disease (PD), impulse control disorder (ICD) can result from dopaminergic medication use, particularly Dopamine Agonists (DAA). Behaviors associated with ICD include hypersexuality as well as compulsive gambling, shopping, and eating, and are potentially linked to alterations to risk processing. Using the Balloon Analogue Risk task, we assessed the role of agonist therapy on risk-taking behavior in PD patients with (n=22) and without (n=19) active ICD symptoms. Patients performed the task both ‘on’ and ‘off’ DAA. DAA increased risk-taking in PD patients with active ICD symptoms, but did not affect risk behavior of PD controls. DAA dose was also important in explaining risk behavior. Both groups similarly reduced their risk-taking in high compared to low risk conditions and following the occurrence of a negative consequence, suggesting that ICD patients do not necessarily differ in their ability to process and adjust to some aspects of negative consequences. Our findings suggest dopaminergic augmentation of risk-taking behavior as a potential contributing mechanism for the emergence of ICD in PD patients. PMID:21604834
Forecasted economic change and the self-fulfilling prophecy in economic decision-making
2017-01-01
This study addresses the self-fulfilling prophecy effect, in the domain of economic decision-making. We present experimental data in support of the hypothesis that speculative forecasts of economic change can impact individuals’ economic decision behavior, prior to any realized changes. In a within-subjects experiment, participants (N = 40) played 180 trials in a Balloon Analogue Risk Talk (BART) in which they could make actual profit. Simple messages about possible (positive and negative) changes in outcome probabilities of future trials had significant effects on measures of risk taking (number of inflations) and actual profits in the game. These effects were enduring, even though no systematic changes in actual outcome probabilities took place following any of the messages. Risk taking also found to be reflected in reaction times revealing increasing reaction times with riskier decisions. Positive and negative economic forecasts affected reaction times slopes differently, with negative forecasts resulting in increased reaction time slopes as a function of risk. These findings suggest that forecasted positive or negative economic change can bias people’s mental model of the economy and reduce or stimulate risk taking. Possible implications for media-fulfilling prophecies in the domain of the economy are considered. PMID:28334031
Bornemann, Rahel; Jansen, Tom R; Kabir, Koroush; Pennekamp, Peter H; Stüwe, Brit; Wirtz, Dieter C; Pflugmacher, Robert
2017-04-01
A retrospective study. The aim of this study was the evaluation of the safety and effectiveness of radiofrequency-targeted vertebral augmentation (RF-TVA) in comparison with balloon kyphoplasty (BK) for the treatment of acute painful vertebral compression fractures (VCFs) on the basis of matched pairs. Vertebroplasty and BK are the common surgical interventions for the treatment of VCF. Both are effective and safe but pose some risks such as adjacent fractures and cement leakage. In 2009, RF-TVA was introduced as an innovative augmentation procedure for the treatment of VCF. A total of 192 patients (116 female; 51-90 y) with VCF (n=303) at 1 to 3 levels were treated with RF-TVA or BK. Functionality (Oswestry Disability Index), pain (visual analogue scale), vertebral height (anterior, middle), and kyphotic angle were evaluated over a 2-year period (postoperatively, 3-4 d, 3, 6, 12, and 24 mo). In addition, operating time and occurrence of cement leakage were recorded. Pain and functionality were significantly improved after both treatments. In both groups, there was an increase in the vertebral height and a decrease in the kyphotic angle, which remained relatively consistent during 24 months. The incidence of cement leakage was 9.4% (n=9) in the RF-TVA group and 24.0% (n=25) in the BK group. The mean operating time with radiofrequency kyphoplasty was 25.9±9.9 minutes, and with balloon kyphoplasty 48.0±18.4 minutes. RF-TVA is a safe and effective procedure for the treatment of vertebral compression fractures when compared with BK. Improvement in pain and functional scores after RF-TVA are durable through 24 months postprocedure and remained better than those after BK at long-term follow-up. Operating time for RF-TVA is shorter and the risk of cement leakage is lower. Both procedures provided similar results in vertebral height restoration and reduction in the kyphotic angle.
Risk-taking, peer-influence and child maltreatment: a neurocognitive investigation
Hoffmann, Ferdinand; Puetz, Vanessa B; Viding, Essi; Sethi, Arjun; Palmer, Amy
2018-01-01
Abstract Maltreatment is associated with increased risk of a range of psychiatric disorders, many of which are characterized by altered risk-taking propensity. Currently, little is known about the neural correlates of risk-taking in children exposed to maltreatment, nor whether their risk-taking is atypically modulated by peer influence. Seventy-five 10- to 14-year-old children [maltreated (MT) group: N = 41; non-maltreated Group (NMT): N = 34] performed a Balloon Analogue Risk Task (BART), under three different peer influence conditions: while alone, while being observed by a peer and while being encouraged by a peer to take risks. The MT group engaged in less risk-taking irrespective of peer influence. There was no differential effect of peer influence on risk-taking behaviour across groups. At the neural level, the right anterior insula (rAI) exhibited altered risk sensitivity across conditions in the MT group. Across groups and conditions, rAI risk sensitivity was negatively associated with risk-taking and within the MT group greater rAI risk sensitivity was related to more anxiety symptoms. These findings suggest that children with a history of maltreatment show reduced risk-taking but typical responses to peer influence. Abnormal rAI functioning contributes to the pattern of reduced risk-taking and may predispose children exposed to maltreatment to develop future psychopathology. PMID:29069467
Risk-taking, peer-influence and child maltreatment: a neurocognitive investigation.
Hoffmann, Ferdinand; Puetz, Vanessa B; Viding, Essi; Sethi, Arjun; Palmer, Amy; McCrory, Eamon J
2018-01-01
Maltreatment is associated with increased risk of a range of psychiatric disorders, many of which are characterized by altered risk-taking propensity. Currently, little is known about the neural correlates of risk-taking in children exposed to maltreatment, nor whether their risk-taking is atypically modulated by peer influence. Seventy-five 10- to 14-year-old children [maltreated (MT) group: N = 41; non-maltreated Group (NMT): N = 34] performed a Balloon Analogue Risk Task (BART), under three different peer influence conditions: while alone, while being observed by a peer and while being encouraged by a peer to take risks. The MT group engaged in less risk-taking irrespective of peer influence. There was no differential effect of peer influence on risk-taking behaviour across groups. At the neural level, the right anterior insula (rAI) exhibited altered risk sensitivity across conditions in the MT group. Across groups and conditions, rAI risk sensitivity was negatively associated with risk-taking and within the MT group greater rAI risk sensitivity was related to more anxiety symptoms. These findings suggest that children with a history of maltreatment show reduced risk-taking but typical responses to peer influence. Abnormal rAI functioning contributes to the pattern of reduced risk-taking and may predispose children exposed to maltreatment to develop future psychopathology. © The Author (2017). Published by Oxford University Press.
Sounding rocket and balloon flight safety philosophy and methodologies
NASA Technical Reports Server (NTRS)
Beyma, R. J.
1986-01-01
NASA's sounding rocket and balloon goal is to successfully and safely perform scientific research. This is reflected in the design, planning, and conduct of sounding rocket and balloon operations. The purpose of this paper is to acquaint the sounding rocket and balloon scientific community with flight safety philosophy and methodologies, and how range safety affects their programs. This paper presents the flight safety philosophy for protecting the public against the risk created by the conduct of sounding rocket and balloon operations. The flight safety criteria used to implement this philosophy are defined and the methodologies used to calculate mission risk are described.
Kiat, John; Straley, Elizabeth; Cheadle, Jacob E
2016-03-01
Young people frequently socialize together in contexts that encourage risky decision making, pointing to a need for research into how susceptibility to peer influence is related to individual differences in the neural processing of decisions during sequentially escalating risk. We applied a novel analytic approach to analyze EEG activity from college-going students while they completed the Balloon Analogue Risk Task (BART), a well-established risk-taking propensity assessment. By modeling outcome-processing-related changes in the P200 and feedback-related negativity (FRN) sequentially within each BART trial as a function of pump order as an index of increasing risk, our results suggest that analyzing the BART in a progressive fashion may provide valuable new insights into the temporal neurophysiological dynamics of risk taking. Our results showed that a P200, localized to the left caudate nucleus, and an FRN, localized to the left dACC, were positively correlated with the level of risk taking and reward. Furthermore, consistent with our hypotheses, the rate of change in the FRN was higher among college students with greater self-reported resistance to peer influence. © The Author (2015). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Functional brain imaging in irritable bowel syndrome with rectal balloon-distention by using fMRI.
Yuan, Yao-Zong; Tao, Ran-Jun; Xu, Bin; Sun, Jing; Chen, Ke-Min; Miao, Fei; Zhang, Zhong-Wei; Xu, Jia-Yu
2003-06-01
Irritable bowel syndrome (IBS) is characterized by abdominal pain and changes in stool habits. Visceral hypersensitivity is a key factor in the pathophysiology of IBS. The aim of this study was to examine the effect of rectal balloon-distention stimulus by blood oxygenation level-dependent functional magnetic resonance imaging (BOLD-fMRI) in visceral pain center and to compare the distribution, extent, and intensity of activated areas between IBS patients and normal controls. Twenty-six patients with IBS and eleven normal controls were tested for rectal sensation, and the subjective pain intensity at 90 ml and 120 ml rectal balloon-distention was reported by using Visual Analogue Scale. Then, BOLD-fMRI was performed at 30 ml, 60 ml, 90 ml, and 120 ml rectal balloon-distention in all subjects. Rectal distention stimulation increased the activity of anterior cingulate cortex (35/37), insular cortex (37/37), prefrontal cortex (37/37), and thalamus (35/37) in most cases. At 120 ml of rectal balloon-distention, the activation area and percentage change in MR signal intensity of the regions of interest (ROI) at IC, PFC, and THAL were significantly greater in patients with IBS than that in controls. Score of pain sensation at 90 ml and 120 ml rectal balloon-distention was significantly higher in patients with IBS than that in controls. Using fMRI, some patients with IBS can be detected having visceral hypersensitivity in response to painful rectal balloon-distention. fMRI is an objective brain imaging technique to measure the change in regional cerebral activation more precisely. In this study, IC and PFC of the IBS patients were the major loci of the CNS processing of visceral perception.
Rocha Ferreira, Graziela Santos; de Almeida, Juliano Pinheiro; Landoni, Giovanni; Vincent, Jean Louis; Fominskiy, Evgeny; Gomes Galas, Filomena Regina Barbosa; Gaiotto, Fabio A; Dallan, Luís Oliveira; Franco, Rafael Alves; Lisboa, Luiz Augusto; Palma Dallan, Luis Roberto; Fukushima, Julia Tizue; Rizk, Stephanie Itala; Park, Clarice Lee; Strabelli, Tânia Mara; Gelas Lage, Silvia Helena; Camara, Ligia; Zeferino, Suely; Jardim, Jaquelline; Calvo Arita, Elisandra Cristina Trevisan; Caldas Ribeiro, Juliana; Ayub-Ferreira, Silvia Moreira; Costa Auler, Jose Otavio; Filho, Roberto Kalil; Jatene, Fabio Biscegli; Hajjar, Ludhmila Abrahao
2018-04-30
The aim of this study was to evaluate the efficacy of perioperative intra-aortic balloon pump use in high-risk cardiac surgery patients. A single-center randomized controlled trial and a meta-analysis of randomized controlled trials. Heart Institute of São Paulo University. High-risk patients undergoing elective coronary artery bypass surgery. Patients were randomized to receive preskin incision intra-aortic balloon pump insertion after anesthesia induction versus no intra-aortic balloon pump use. The primary outcome was a composite endpoint of 30-day mortality and major morbidity (cardiogenic shock, stroke, acute renal failure, mediastinitis, prolonged mechanical ventilation, and a need for reoperation). A total of 181 patients (mean [SD] age 65.4 [9.4] yr; 32% female) were randomized. The primary outcome was observed in 43 patients (47.8%) in the intra-aortic balloon pump group and 42 patients (46.2%) in the control group (p = 0.46). The median duration of inotrope use (51 hr [interquartile range, 32-94 hr] vs 39 hr [interquartile range, 25-66 hr]; p = 0.007) and the ICU length of stay (5 d [interquartile range, 3-8 d] vs 4 d [interquartile range, 3-6 d]; p = 0.035) were longer in the intra-aortic balloon pump group than in the control group. A meta-analysis of 11 randomized controlled trials confirmed a lack of survival improvement in high-risk cardiac surgery patients with perioperative intra-aortic balloon pump use. In high-risk patients undergoing cardiac surgery, the perioperative use of an intra-aortic balloon pump did not reduce the occurrence of a composite outcome of 30-day mortality and major complications compared with usual care alone.
Wise, Richard J; Phung, Alissa L; Labuschagne, Izelle; Stout, Julie C
2015-01-01
Urgency is the tendency to make impulsive decisions under extreme positive or negative emotional states. Stress, gender and impulsive personality traits are all known to influence decision-making, but no studies have examined the interplay of all of these factors. We exposed 78 men and women to a stress or a non-stress condition, and then administered the Balloon Analogue Risk Task. We found that stress effects varied as a function of gender and urgency traits. Under stress, women low in negative urgency and men high in negative urgency made fewer risky decisions. Positive urgency yielded a similar pattern. Thus, decisions under stress depend on a complex interplay between gender and impulsive personality traits. These findings have implications for clinical disorders, such as substance use disorders, in which there are known deficits in decision-making and high levels of impulsive traits.
Evidence for deficits in reward responsivity in antisocial youth with callous-unemotional traits.
Marini, Victoria A; Stickle, Timothy R
2010-10-01
This study investigated reward responsivity in youth with high levels of callous-unemotional (CU) traits using a cross-sectional design. Whereas deficits in responding to punishment cues are well established in youth with CU traits, it is unclear whether responsivity to rewarding stimuli is impaired as well. Participants were 148 predominantly Caucasian, adjudicated adolescents between the ages of 11 and 17 (M = 15.1, SD = 1.4) who completed the Balloon Analogue Risk Task as part of a larger battery investigating aggression and social information processing. A Reward Responsivity variable was created to capture changes in participants' responding after receiving a reward. A hierarchical regression analysis indicated that higher levels of CU traits significantly predicted less reward responsivity, above and beyond gender, sensation seeking, and impulsivity. Results support Blair's (2004) Integrated Emotion Systems model that proposes individuals with CU traits are impaired in their responsivity to both appetitive and aversive stimuli.
Spalteholz, Matthias; Strasser, Evald; Hantel, Torsten; Gahr, Ralf Herbert
2014-01-01
Purpose: Vertebral compression fractures are the most common fractures in the elderly. Long lasting pain and deformity is responsible for consecutive impairment with markedly reduced life quality, increased morbidity and mortality. The beneficial effects of balloon kyphoplasty are verified in many studies. Subsequent fracture risk is not finally clarified, cement related risks and deformity related risks are discussed. There is less knowledge about the risk of bone marrow edema and new fractures during balloon kyphoplasty procedure. The goal of this study is to examine, if prone position during kyphoplasty is an independent risk factor for new fractures in the osteoporotic spine. Methods: Consecutive MRI study of 20 patients with fresh, non-traumatic thoracolumbar vertebral compression fractures and balloon kyphoplasty treatment. MRI Scans of the thoracolumbar spine were obtained after surgery, before patients have been mobilized. Specific MRI changes like new bone marrow edema, signal intensity changes in adjacent and remote segments and new fractures were assessed by specialized neuro-radiologist. Results: 20 MR images were examined within 48 hours after balloon kyphoplasty procedure. 85% did not show bone marrow edema extent changes after kyphoplasty. We found minor increase of bone marrow edema within the augmented vertebral body in 3 cases. We did not find any new bone marrow edema and no new fractures in adjacent and remote segments after balloon kyphoplasty treatment. Conclusion: Prone position leads to no new bone marrow edema and no new fractures in the osteoporotic spine. Accordingly, prone position has no risk for adjacent level fractures in osteoporotic spines. PMID:26504728
Eckard, D A; O'Boynick, P L; Han, P P
1996-11-01
Unintentional intracerebral embolization is a serious, ever present threat during neurointerventional procedures. We have devised a method to reduce this intraprocedural risk in vertebral artery interventions by creating a temporary subclavian steal. For this technique, a temporary balloon occlusion catheter is advanced into the proximal subclavian artery via a femoral artery approach, while a second introducer catheter is passed into the target vertebral artery via an axillary artery access. The temporary occluding balloon is then inflated within the proximal subclavian artery, establishing a subclavian steal that diverts blood flow into the arm. Permanent balloon occlusion of the vertebral artery can then be accomplished without fear of intracerebral embolization. Two patients with vertebrobasilar junction aneurysms were successfully treated with detachable balloon embolization using this cerebral protection technique. The permanent occlusion balloons were easily passed through the introducer catheter without difficulty despite reversed vertebral artery flow. No complications were encountered, and the aneurysms were successfully occluded in both patients. Temporary subclavian steal can be easily created to reduce the risk of cerebral embolic complications when performing interventional neuroradiological procedures in the vertebral artery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saini, Amarjit S.; Zhang, Geoffrey G., E-mail: geoffrey.zhang@moffitt.org; Finkelstein, Steven E.
2011-07-15
Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken withmore » each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.« less
Veling, Harm; Bijleveld, Erik
2015-12-01
Valuable monetary rewards can boost human performance on various effortful tasks even when the value of the rewards is presented too briefly to allow for strategic decision making. However, the mechanism by which briefly-presented reward information influences performance has remained unclear. One possibility is that performance after briefly-presented reward information is primarily boosted via activation of the dopamine reward system, whereas performance after very visible reward information is driven more by strategic processes. To examine this hypothesis, we first presented participants with a task in which they could earn rewards of relatively low (1 cent) or high (10 cents) value, and the value information was presented either briefly (17 ms) or for an extended duration (300 ms). Furthermore, responsiveness of the dopamine system was indirectly estimated with a measure of risk taking, the Balloon Analogue Risk Task (BART). Results showed that performance after high- compared to low-value rewards was indeed related to the BART scores only when reward information was presented briefly. These results are suggestive of the possibility that brief presentation of reward information boosts performance directly via activating the dopamine system, whereas extended presentation of reward information leads to more strategic reward-driven behavior. Copyright © 2015 Elsevier Inc. All rights reserved.
Ba, Yutao; Zhang, Wei; Peng, QiJia; Salvendy, Gavriel; Crundall, David
2016-01-01
Drivers' risk-taking is a key issue of road safety. This study explored individual differences in drivers' decision-making, linking external behaviours to internal neural activity, to reveal the cognitive mechanisms of risky driving. Twenty-four male drivers were split into two groups (risky vs. safe drivers) via the Drivier Behaviour Questionnaire-violation. The risky drivers demonstrated higher preference for the risky choices in the paradigms of Iowa Gambling Task and Balloon Analogue Risk Task. More importantly, the risky drivers showed lower amplitudes of feedback-related negativity (FRN) and loss-minus-gain FRN in both paradigms, which indicated their neural processing of error-detection. A significant difference of P300 amplitudes was also reported between groups, which indicated their neural processing of reward-evaluation and were modified by specific paradigm and feedback. These results suggested that the neural basis of risky driving was the decision patterns less revised by losses and more motivated by rewards. Risk-taking on the road is largely determined by inherent cognitive mechanisms, which can be indicated by the behavioural and neural patterns of decision-making. In this regard, it is feasible to quantize drivers’ riskiness in the cognitive stage before actual risky driving or accidents, and intervene accordingly.
Cortisol boosts risky decision-making behavior in men but not in women.
Kluen, Lisa Marieke; Agorastos, Agorastos; Wiedemann, Klaus; Schwabe, Lars
2017-10-01
Acute stress may escalate risky decision-making in men, while there is no such effect in women. Although first evidence links these gender-specific effects of stress to stress-induced changes in cortisol, whether elevated cortisol is indeed sufficient to boost risk-taking, whether a potential cortisol effect depends on simultaneous noradrenergic activation, and whether cortisol and noradrenergic activation exert distinct effects on risk-taking in men and women is unknown. In this experiment, we therefore set out to elucidate the impact of cortisol and noradrenergic stimulation on risky decision-making in men and women. In a fully-crossed, placebo-controlled, double-blind design, male and female participants received orally either a placebo, hydrocortisone, yohimbine, an alpha-2-adrenoceptor-antagonist leading to increased noradrenergic stimulation, or both drugs before completing the balloon analogue risk task, a validated measure of risk-taking. Overall, participants' choice was risk-sensitive as reflected in reduced responding in high- compared to moderate- and low-risk conditions. Cortisol, however, led to a striking increase in risk-taking in men, whereas it had no effect on risk-taking behavior in women. Yohimbine had no such effect and the gender-specific effect of cortisol was not modulated by yohimbine. Our data show that cortisol boosts risk-taking behavior in men but not in women. This differential effect of cortisol on risk-taking may drive gender differences in risky decision-making under stress. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ryan, Katherine K.; MacKillop, James; Carpenter, Matthew J.
2012-01-01
Impulsivity and risk-taking propensity are neurobehavioral traits that reliably distinguish between smoking and non-smoking adults. However, how these traits relate to smoking quantity and nicotine dependence among older adolescent smokers is unclear. The current study examined impulsivity and risk-taking propensity in relation to smoking behavior and nicotine dependence among current older adolescent smokers (age 16–20 years; N = 107). Participants completed the Barratt Impulsiveness Scale–11 (BIS-11), the Balloon Analogue Risk Task (BART), and self-report measures of smoking behavior and nicotine dependence. Results indicated a significant positive relationship between nicotine dependence and the Attention subscale (β =.20, t = 2.07, p <.05) and the Non-planning subscale (β =.19, t=1.92, p<.06) of the BIS-11. Contrary to expectation, the results also indicated a significant negative relationship between performance on the BART and nicotine dependence (β = −.19, t=−2.18, p <.05), such that greater risk-taking propensity was associated with less dependence. These data suggest that impulsivity and risk-taking propensity are related to older adolescent smoking but are separable traits with distinguishable associations to nicotine dependence among adolescents. These findings support the notion that impulsivity is related to heightened nicotine dependence, but suggest the relationship between risk-taking propensity and nicotine dependence is more ambiguous and warrants further investigation. PMID:23006247
Yau, Yvonne H C; Potenza, Marc N; Mayes, Linda C; Crowley, Michael J
2015-06-01
While the conceptualization of problematic Internet use (PIU) as a "behavioral addiction" resembling substance-use disorders is debated, the neurobiological underpinnings of PIU remain understudied. This study examined whether adolescents displaying features of PIU (at-risk PIU; ARPIU) are more impulsive and exhibit blunted responding in the neural mechanisms underlying feedback processing and outcome evaluation during risk-taking. Event-related potentials (ERPs) elicited by positive (i.e. reward) and negative (i.e. loss) feedback were recorded during performance on a modified version of the Balloon Analogue Risk Task (BART) among ARPIU (n=39) and non-ARPIU subjects (n=27). Compared to non-ARPIU, ARPIU adolescents displayed higher levels of urgency and lack of perseverance on the UPPS Impulsive Behavior Scale. Although no between-group difference in BART performance was observed, ERPs demonstrated overall decreased sensitivity to feedback in ARPIU compared to non-ARPIU adolescents, as indexed by blunted feedback-related negativity (FRN) and P300 amplitudes to both negative and positive feedback. The present study provides evidence for feedback processing during risk-taking as a neural correlate of ARPIU. Given recent concerns regarding the growing prevalence of PIU as a health concern, future work should examine the extent to which feedback processing may represent a risk factor for PIU, a consequence of PIU, or possibly both. Copyright © 2015 Elsevier Ltd. All rights reserved.
Severe Sunburn After a Hot Air Balloon Ride: A Case Report and Literature Review.
Ozturk, Sinan; Karagoz, Huseyin
2015-01-01
Hot air balloon tours are very popular among travelers worldwide. Preventable burn injuries associated with hot air balloon rides have been reported during crashes into power lines, in propane burner explosions, and following contact with the propane burner tanks. We present a case of severe repeated sunburn, which poses another risk of preventable injury during hot air balloon rides, and briefly discuss the injury epidemiology of hot air balloon rides. © 2015 International Society of Travel Medicine.
Nakazaki, Masahito; Nonaka, Tadashi; Takahashi, Akira; Yonemasu, Yasuyuki; Nomura, Tatsufumi; Onda, Toshiyuki; Honda, Osamu; Hashimoto, Yuji; Ohnishi, Hirofumi; Sasaki, Masanori; Daibo, Masahiko; Honmou, Osamu
2016-07-01
The use of distal filter protection alone is associated with a high risk of ischemic complications when vulnerable carotid stenosis is treated by carotid artery stenting (CAS). Double balloon protection, a combination of distal balloon protection and proximal balloon occlusion, can be utilized. We assessed the outcome and complications of the double balloon protection method for vulnerable carotid stenosis. Among 130 patients who underwent CAS from 2009 to 2014, we enrolled the following patients: those whose target lesion was vulnerable as evaluated by MRI, i.e., a signal ratio of plaque to posterior cervical muscle on T1-weighted images before CAS of ≥1.5, and those who underwent diffusion-weighted imaging (DWI) studies within 48 h after the procedure. Ninety patients were enrolled. We investigated DWI findings of the double balloon protection group compared with those of the simple distal balloon protection and distal filter protection groups. Sixty-four patients (71 %) underwent double balloon protection, 15 patients (17 %) simple distal balloon protection, and 11 patients (12 %) distal filter protection. Symptomatic embolic complications and new lesions on DWI after CAS were significantly less common in patients undergoing double balloon protection compared to distal balloon protection or distal filter protection (0 % vs. 20 %, 9 %, P < 0.01, and 30 % vs. 67 %, 82 %, P < 0.01, respectively). Logistic regression analysis also identified the odds ratio of double balloon protection for new lesions on DWI after CAS of 0.23 (95 % confidence interval: 0.07-0.70, P < 0.01) compared to simple distal protections. In the patients who underwent CAS for vulnerable carotid stenosis, double balloon protection was an independent significant factor associated with a reduction in the risk of new lesions on DWI after the procedure compared to conventional distal protections.
Tutton, Sean M; Pflugmacher, Robert; Davidian, Mark; Beall, Douglas P; Facchini, Francis R; Garfin, Steven R
2015-06-15
The KAST (Kiva Safety and Effectiveness Trial) study was a pivotal, multicenter, randomized control trial for evaluation of safety and effectiveness in the treatment of patients with painful, osteoporotic vertebral compression fractures (VCFs). The objective was to demonstrate noninferiority of the Kiva system to balloon kyphoplasty (BK) with respect to the composite primary endpoint. Annual incidence of osteoporotic VCFs is prevalent. Optimal treatment of VCFs should address pain, function, and deformity. Kiva is a novel implant for vertebral augmentation in the treatment of VCFs. A total of 300 subjects with 1 or 2 painful osteoporotic VCFs were randomized to blindly receive Kiva (n = 153) or BK (n = 147). Subjects were followed through 12 months. The primary endpoint was a composite at 12 months defined as a reduction in fracture pain by at least 15 mm on the visual analogue scale, maintenance or improvement in function on the Oswestry Disability Index, and absence of device-related serious adverse events. Secondary endpoints included cement usage, extravasation, and adjacent level fracture. A mean improvement of 70.8 and 71.8 points in the visual analogue scale score and 38.1 and 42.2 points in the Oswestry Disability Index was noted in Kiva and BK, respectively. No device-related serious adverse events occurred. Despite significant differences in risk factors favoring the control group at baseline, the primary endpoint demonstrated noninferiority of Kiva to BK. Analysis of secondary endpoints revealed superiority with respect to cement use and site-reported extravasation and a positive trend in adjacent level fracture warranting further study. The KAST study successfully established that the Kiva system is noninferior to BK based on a composite primary endpoint assessment incorporating pain-, function-, and device-related serious adverse events for the treatment of VCFs due to osteoporosis. Kiva was shown to be noninferior to BK and revealed a positive trend in several secondary endpoints. 1.
Cross-cultural standardization of the South Texas Assessment of Neurocognition in India.
Cherkil, S; Satish, S; Mathew, S S; Dinesh, N; Kumar, C T S; Lombardo, L E; Glahn, D C; Frangou, S
2012-08-01
Despite the central role of cognition for mental disorders most studies have been conducted in western countries. Similar research from other parts of the world, particularly India, is very limited. As a first step in closing this gap this cross-cultural comparability study of the South Texas Assessment of Neurocognition (STAN) battery was conducted between USA and India. One hundred healthy adults from Kerala, India, were administered six language independent subtests of the Java Neuropsychological Test (JANET) version of the STAN, assessing aspects of general intellectual ability (Matrix Reasoning), attention (Identical Pairs Continuous Performance, 3 Symbol Version Test; IPCPTS), working memory (Spatial Capacity Delayed Response Test; SCAP), response inhibition (Stop Signal Reaction Time; SSRT), Emotional Recognition and Risk taking (Balloon Analogue Risk Task; BART). Test results were compared to a demographically matched US sample. Overall test performance in the Kerala sample was comparable to that of the US sample and commensurate to that generally described in studies from western countries. Our results support the metric equivalence of currently available cognitive test batteries developed in western countries for use in India. However, the sample was restricted to individuals who were literate and had completed basic primary and secondary education.
A further assessment of decision-making in anorexia nervosa.
Adoue, C; Jaussent, I; Olié, E; Beziat, S; Van den Eynde, F; Courtet, P; Guillaume, S
2015-01-01
Anorexia nervosa (AN) may be associated with impaired decision-making. Cognitive processes underlying this impairment remain unclear, mainly because previous assessments of this complex cognitive function were completed with a single test. Furthermore, clinical features such as mood status may impact this association. We aim to further explore the hypothesis of altered decision-making in AN. Sixty-three adult women with AN and 49 female controls completed a clinical assessment and were assessed by three tasks related to decision-making [Iowa Gambling Task (IGT), Balloon Analogue Risk Task (BART), Probabilistic Reversal Learning Task (PRLT)]. People with AN had poorer performance on the IGT and made less risky choices on the BART, whereas performances were not different on PRLT. Notably, AN patients with a current major depressive disorder showed similar performance to those with no current major depressive disorder. These results tend to confirm an impaired decision making-process in people with AN and suggest that various cognitive processes such as inhibition to risk-taking or intolerance of uncertainty may underlie this condition Furthermore, these impairments seem unrelated to the potential co-occurent major depressive disorders. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Risk-taking and alcohol use disorders symptomatology in a sample of problem drinkers.
Ashenhurst, James R; Jentsch, J David; Ray, Lara A
2011-10-01
The relationship between risk-taking behavior and alcohol use disorder (AUD) symptoms is poorly understood. This study employed a modified version of a behavioral measure of risk-taking, the Balloon Analogue Risk Task (BART), to examine its relationship to alcohol use and related symptoms in a community sample of individuals with or at risk for AUD. A total of 158 (71.9% male) participants completed a testing battery that included the BART, a structured diagnostic interview for AUD, and measures of alcohol use and related problems. Estimates of IQ and working memory were assessed as covariates. Results indicated that the relationship between risk-taking propensity, as assessed by the BART, and alcohol problems was significant and negative. Individuals with higher symptom count made fewer pumps per trial on the BART, indicating less risk-taking. It is important to note that this relationship was attenuated when controlling for estimated IQ and working memory span. Further examination demonstrated that IQ and age mediated the relationship between risk-taking propensity and symptom count. The main negative relationship observed between risk-taking on the BART and alcohol use and AUD symptomatology in this sample stands in contrast to the positive relationships observed in adolescent and nonclinical samples. Together, these findings highlight the need to consider development and the course of addiction to fully elucidate the effects of risky-decision making on AUD liability. Furthermore, our results demonstrate the importance of inclusion of neurocognitive covariates (IQ), as well as demographic variables (age) when using this task.
The influence of groups and alcohol consumption on individual risk-taking.
Erskine-Shaw, Marianne; Monk, Rebecca L; Qureshi, Adam W; Heim, Derek
2017-10-01
Research addressing the influence of alcohol and groups on risky behaviour has yielded contradictory findings regarding the extent to which intoxicated groups exaggerate or minimise risk-taking. Previous work has examined the effect of intoxication on risk-taking focusing on collective group decision-making, and to date the influence of alcohol consumption and groups on individual risk-taking has yet to be explored experimentally. The current study therefore examined the impact of intoxication and groups on individual risk-taking. In a mixed design, 99 social drinkers (62 female) attended an experimental session individually (N=48) or in groups of three (N=51). Individuals completed the study in isolation while groups were tested in the same room. Participants completed two behavioural measures of risk-taking: Balloon Analogue Risk Task (BART) and Stoplight Task (SLT), both before and following consumption of an alcoholic (0.6g/kg males, 0.5g/kg females) or a placebo beverage. Those who participated in groups took significantly more risks in both tasks than those in isolation. Alcohol did not increase risk-taking on either risk-taking tasks. However, those who consumed placebo were significantly less risky on the SLT, compared to baseline. No interactions were found between context and beverage on risk-taking. The findings do not support a combined effect of alcohol and groups on individual risk-taking. Rather, results indicate that risk-taking behaviour is influenced by peer presence regardless of alcohol consumption. Targeting the influence of groups (above those of alcohol) may hold promise for reducing risk-taking behaviours in drinking environments. Copyright © 2017 Elsevier B.V. All rights reserved.
Schonberg, Tom; Fox, Craig R.; Mumford, Jeanette A.; Congdon, Eliza; Trepel, Christopher; Poldrack, Russell A.
2012-01-01
Functional imaging studies examining the neural correlates of risk have mainly relied on paradigms involving exposure to simple chance gambles and an economic definition of risk as variance in the probability distribution over possible outcomes. However, there is little evidence that choices made during gambling tasks predict naturalistic risk-taking behaviors such as drug use, extreme sports, or even equity investing. To better understand the neural basis of naturalistic risk-taking, we scanned participants using fMRI while they completed the Balloon Analog Risk Task, an experimental measure that includes an active decision/choice component and that has been found to correlate with a number of naturalistic risk-taking behaviors. In the task, as in many naturalistic settings, escalating risk-taking occurs under uncertainty and might be experienced either as the accumulation of greater potential rewards, or as exposure to increasing possible losses (and decreasing expected value). We found that areas previously linked to risk and risk-taking (bilateral anterior insula, anterior cingulate cortex, and right dorsolateral prefrontal cortex) were activated as participants continued to inflate balloons. Interestingly, we found that ventromedial prefrontal cortex (vmPFC) activity decreased as participants further expanded balloons. In light of previous findings implicating the vmPFC in value calculation, this result suggests that escalating risk-taking in the task might be perceived as exposure to increasing possible losses (and decreasing expected value) rather than the increasing potential total reward relative to the starting point of the trial. A better understanding of how neural activity changes with risk-taking behavior in the task offers insight into the potential neural mechanisms driving naturalistic risk-taking. PMID:22675289
Adolescent Balloon Analog Risk Task and Behaviors that Influence Risk of Motor Vehicle Crash Injury
Vaca, Federico E.; Walthall, Jessica M.; Ryan, Sheryl; Moriarty-Daley, Alison; Riera, Antonio; Crowley, Michael J.; Mayes, Linda C.
2013-01-01
Risk-taking propensity is a pivotal facet of motor vehicle crash involvement and subsequent traumatic injury in adolescents. Clinical encounters are important opportunities to identify teens with high risk-taking propensity who may later experience serious injury. Our objective was to compare self-reports of health risk behavior with performance on the Balloon Analog Risk Task (BART), a validated metric of risk-taking propensity, in adolescents during a clinical encounter. 100 adolescent patients from a hospital emergency department and adolescent health clinic completed a computer-based survey of self-reported risk behaviors including substance use behaviors and behaviors that influence crash involvement. They then completed the BART, a validated laboratory-based risk task in which participants earn points by pumping up a computer-generated balloon with greater pumps leading to increased chance of balloon explosion. 20 trials were undertaken. Mean number of pumps on the BART showed a correlation of .243 (p=.015) with self-reported driver/passenger behaviors and attitudes towards driving that influence risk of crash injury. Regression analyses showed that self-reports of substance use and mean number of pumps on the BART uniquely predict self-reports of behaviors influencing the risk of crash injury. The BART is a promising correlate of real-world risk-taking behavior related to traffic safety. It remains a valid predictor of behaviors influencing risk of crash injury when using just 10 trials, suggesting its utility as a quick and effective screening measure for use in busy clinical environments. This tool may be an important link to prevention interventions for those most at-risk for future motor vehicle crash involvement and injury. PMID:24406948
Xu, Xiao-Quan; Liu, Sheng; Zu, Qing-Quan; Zhao, Lin-Bo; Xia, Jin-Guo; Zhou, Chun-Gao; Zhou, Wei-Zhong
2013-01-01
Background and Purpose This study evaluated the clinical value of detachable-balloon embolization for traumatic carotid-cavernous fistula (TCCF), focusing on the frequency, risk factors, and retreatment of recurrence. Methods Fifty-eight patients with TCCF underwent transarterial detachable-balloon embolization between October 2004 and March 2011. The clinical follow-up was performed every 3 months until up to 3 years postprocedure. Each patient was placed in either the recurrence group or the nonrecurrence group according to whether a recurrence developed after the first procedure. The relevant factors including gender, fistula location, interval between trauma and the interventional procedure, blood flow in the carotid-cavernous fistula, number of balloons, and whether the internal carotid artery (ICA) was sacrificed were evaluated. Results All 58 TCCFs were successfully treated with transarterial balloon embolization, including 7 patients with ICA sacrifice. Recurrent fistulas occurred in seven patients during the follow-up period. Univariate analysis indicated that the interval between trauma and the interventional procedure (p=0.006) might be the main factor related to the recurrence of TCCF. The second treatments involved ICA sacrifice in two patients, fistula embolization with balloons in four patients, and placement of a covered stent in one patient. Conclusions Detachable balloons can still serve as the first-line treatment for TCCFs and recurrent TCCFs despite having a nonnegligible recurrence rate. Shortening the interval between trauma and the interventional procedure may reduce the risk of recurrence. PMID:23626645
A Survey of Titan Balloon Concepts and Technology Status
NASA Technical Reports Server (NTRS)
Hall, Jeffery L.
2011-01-01
This paper surveys the options for, and technology status of, balloon vehicles to explore Saturn's moon Titan. A significant amount of Titan balloon concept thinking and technology development has been performed in recent years, particularly following the spectacular results from the descent and landing of the Huygens probe and remote sensing observations by the Cassini spacecraft. There is widespread recognition that a balloon vehicle on the next Titan mission could provide an outstanding and unmatched capability for in situ exploration on a global scale. The rich variety of revealed science targets has combined with a highly favorable Titan flight environment to yield a wide diversity of proposed balloon concepts. The paper presents a conceptual framework for thinking about balloon vehicle design choices and uses it to analyze various Titan options. The result is a list of recommended Titan balloon vehicle concepts that could perform a variety of science missions, along with their projected performance metrics. Recent technology developments for these balloon concepts are discussed to provide context for an assessment of outstanding risk areas and technological maturity. The paper concludes with suggestions for technology investments needed to achieve flight readiness.
Fracture, inflation and floatation embolisation of PTCA balloon.
O'Neill, Louisa; Sowbhaga, Vinay; Owens, Patrick
2015-01-09
This case outlines an unusual complication of coronary intervention, the likely mechanisms leading to this and possible retrieval options. It is the first case to the best of our knowledge reporting this complication. A 78-year-old Caucasian man underwent coronary stenting. During the procedure kinking and subsequent fracture of a non-compliant percutaneous transluminal coronary angioplasty (PTCA) balloon occurred. Injection of contrast down the guide to opacify the coronary arteries resulted in 'inflation' of the balloon with air, and embolisation of the inflated balloon into the proximal left anterior descending artery. The embolised balloon was retrieved by removal of the guide catheter and wire as a unit. The patient had a good angiographic outcome. This case highlights risks associated with usage of kinked balloons catheters, and describes for the first time to our knowledge, the inflation of a PTCA balloon with air from its shaft within the catheter, causing 'floatation' embolisation into the coronary artery. 2015 BMJ Publishing Group Ltd.
Fracture, inflation and floatation embolisation of PTCA balloon
O'Neill, Louisa; Sowbhaga, Vinay; Owens, Patrick
2015-01-01
This case outlines an unusual complication of coronary intervention, the likely mechanisms leading to this and possible retrieval options. It is the first case to the best of our knowledge reporting this complication. A 78-year-old Caucasian man underwent coronary stenting. During the procedure kinking and subsequent fracture of a non-compliant percutaneous transluminal coronary angioplasty (PTCA) balloon occurred. Injection of contrast down the guide to opacify the coronary arteries resulted in ‘inflation’ of the balloon with air, and embolisation of the inflated balloon into the proximal left anterior descending artery. The embolised balloon was retrieved by removal of the guide catheter and wire as a unit. The patient had a good angiographic outcome. This case highlights risks associated with usage of kinked balloons catheters, and describes for the first time to our knowledge, the inflation of a PTCA balloon with air from its shaft within the catheter, causing ‘floatation’ embolisation into the coronary artery. PMID:25576524
Making assessments while taking repeated risks: a pattern of multiple response pathways.
Pleskac, Timothy J; Wershbale, Avishai
2014-02-01
Beyond simply a decision process, repeated risky decisions also require a number of cognitive processes including learning, search and exploration, and attention. In this article, we examine how multiple response pathways develop over repeated risky decisions. Using the Balloon Analogue Risk Task (BART) as a case study, we show that 2 different response pathways emerge over the course of the task. The assessment pathway is a slower, more controlled pathway where participants deliberate over taking a risk. The 2nd pathway is a faster, more automatic process where no deliberation occurs. Results imply the slower assessment pathway is taken as choice conflict increases and that the faster automatic response is a learned response. Based on these results, we modify an existing formal cognitive model of decision making during the BART to account for these dual response pathways. The slower more deliberative response process is modeled with a sequential sampling process where evidence is accumulated to a threshold, while the other response is given automatically. We show that adolescents with conduct disorder and substance use disorder symptoms not only evaluate risks differently during the BART but also differ in the rate at which they develop the more automatic response. More broadly, our results suggest cognitive models of judgment decision making need to transition from treating observed decisions as the result of a single response pathway to the result of multiple response pathways that change and develop over time.
Yeomans, Martin R; Brace, Aaron
2015-01-01
There is increasing evidence that individual differences in tendency to overeat relate to impulsivity, possibly by increasing reactivity to food-related cues in the environment. This study tested whether acute exposure to food cues enhanced impulsive and risky responses in women classified on tendency to overeat, indexed by scores on the three factor eating questionnaire disinhibition (TFEQ-D), restraint (TFEQ-R) and hunger scales. Ninety six healthy women completed two measures of impulsive responding (delayed discounting, DDT and a Go No-Go, GNG, task) and a measure of risky decision making (the balloon analogue risk task, BART) as well as questionnaire measures of impulsive behaviour either after looking at a series of pictures of food or visually matched controls. Impulsivity (DDT) and risk-taking (BART) were both positively associated with TFEQ-D scores, but in both cases this effect was exacerbated by prior exposure to food cues. No effects of restraint were found. TFEQ-D scores were also related to more commission errors on the GNG, while restrained women were slower on the GNG, but neither effect was modified by cue exposure. Overall these data suggest that exposure to food cues act to enhance general impulsive responding in women at risk of overeating and tentatively suggest an important interaction between tendency for impulsive decision making and food cues that may help explain a key underlying risk factor for overeating.
Yeomans, Martin R.; Brace, Aaron
2015-01-01
There is increasing evidence that individual differences in tendency to overeat relate to impulsivity, possibly by increasing reactivity to food-related cues in the environment. This study tested whether acute exposure to food cues enhanced impulsive and risky responses in women classified on tendency to overeat, indexed by scores on the three factor eating questionnaire disinhibition (TFEQ-D), restraint (TFEQ-R) and hunger scales. Ninety six healthy women completed two measures of impulsive responding (delayed discounting, DDT and a Go No-Go, GNG, task) and a measure of risky decision making (the balloon analogue risk task, BART) as well as questionnaire measures of impulsive behaviour either after looking at a series of pictures of food or visually matched controls. Impulsivity (DDT) and risk-taking (BART) were both positively associated with TFEQ-D scores, but in both cases this effect was exacerbated by prior exposure to food cues. No effects of restraint were found. TFEQ-D scores were also related to more commission errors on the GNG, while restrained women were slower on the GNG, but neither effect was modified by cue exposure. Overall these data suggest that exposure to food cues act to enhance general impulsive responding in women at risk of overeating and tentatively suggest an important interaction between tendency for impulsive decision making and food cues that may help explain a key underlying risk factor for overeating. PMID:26378459
Dopamine Gene Profiling to Predict Impulse Control and Effects of Dopamine Agonist Ropinirole.
MacDonald, Hayley J; Stinear, Cathy M; Ren, April; Coxon, James P; Kao, Justin; Macdonald, Lorraine; Snow, Barry; Cramer, Steven C; Byblow, Winston D
2016-07-01
Dopamine agonists can impair inhibitory control and cause impulse control disorders for those with Parkinson disease (PD), although mechanistically this is not well understood. In this study, we hypothesized that the extent of such drug effects on impulse control is related to specific dopamine gene polymorphisms. This double-blind, placebo-controlled study aimed to examine the effect of single doses of 0.5 and 1.0 mg of the dopamine agonist ropinirole on impulse control in healthy adults of typical age for PD onset. Impulse control was measured by stop signal RT on a response inhibition task and by an index of impulsive decision-making on the Balloon Analogue Risk Task. A dopamine genetic risk score quantified basal dopamine neurotransmission from the influence of five genes: catechol-O-methyltransferase, dopamine transporter, and those encoding receptors D1, D2, and D3. With placebo, impulse control was better for the high versus low genetic risk score groups. Ropinirole modulated impulse control in a manner dependent on genetic risk score. For the lower score group, both doses improved response inhibition (decreased stop signal RT) whereas the lower dose reduced impulsiveness in decision-making. Conversely, the higher score group showed a trend for worsened response inhibition on the lower dose whereas both doses increased impulsiveness in decision-making. The implications of the present findings are that genotyping can be used to predict impulse control and whether it will improve or worsen with the administration of dopamine agonists.
Endovascular rescue of a fused monorail balloon and cerebral protection device.
Campbell, John E; Bates, Mark C; Elmore, Michael
2007-08-01
To present a case of successful endovascular retrieval of a monorail predilation balloon fused to an embolic protection device (EPD) in the distal internal carotid artery (ICA) of a high-risk symptomatic patient. A 60-year-old man with documented systemic atherosclerotic disease had a severe (>70%) restenosis in the left ICA 3 years after endarterectomy. He was scheduled for carotid artery stenting (CAS) with cerebral protection; however, he developed unstable angina and was transferred to our facility, where the admitting team decided that staged CAS followed by coronary bypass grafting would be the best option. During the CAS procedure, a 6-mm AccuNet filter was passed across the lesion via a 6-F carotid sheath and deployed in the distal ICA without incident. However, the 4-x20-mm predilation monorail balloon was then advanced without visualizing the markers, resulting in inadvertent aggressive interaction that trapped the balloon's tip in the filter. Several maneuvers to separate the devices were unsuccessful. Finally, the filter/balloon combination was moved gently retrograde until the balloon was straddling the subtotal ICA lesion. The lesion was dilated to 4 mm with the balloon, and the sheath was gently advanced across the lesion as the balloon was deflated. Angiography excluded interval occlusion of the filter from the embolic debris during the aforementioned aggressive maneuvers and documented antegrade flow. The filter was slowly withdrawn into the 6-F sheath with simultaneous aspiration. A second 6-mm filter was deployed, and the procedure was completed satisfactorily. The patient did well, with no neurological sequelae. EPDs are an essential in carotid artery stenting and, keeping in mind the potential risks associated with their use, will help the operator avoid complications such as this one.
Exposure to bright light biases effort-based decisions.
Bijleveld, Erik; Knufinke, Melanie
2018-06-01
Secreted in the evening and the night, melatonin suppresses activity of the mesolimbic dopamine pathway, a brain pathway involved in reward processing. However, exposure to bright light diminishes-or even prevents-melatonin secretion. Thus, we hypothesized that reward processing, in the evening, is more pronounced in bright light (vs. dim light). Healthy human participants carried out three tasks that tapped into various aspects of reward processing (effort expenditure for rewards task [EEfRT]; two-armed bandit task [2ABT]; balloon analogue risk task [BART). Brightness was manipulated within-subjects (bright vs. dim light), in separate evening sessions. During the EEfRT, participants used reward-value information more strongly when they were exposed to bright light (vs. dim light). This finding supported our hypothesis. However, exposure to bright light did not significantly affect task behavior on the 2ABT and the BART. While future research is necessary (e.g., to zoom in on working mechanisms), these findings have potential implications for the design of physical work environments. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Tsuura, M.; Terada, T.; Masuo, O.; Matsumoto, H.; Itakura, T.; Hyoutani, G.; Nakamura, Y.; Moriwaki, H.; Hayashi, S.
2001-01-01
Summary 110 patients with extracranial ICA stenosis were treated by PTA or stenting. In 21 of 55 cases of only PTA and in 40 of 55 cases of stenting, we used our blocking balloon systems to prevent distal embolism. The morbidity and the mortality rates were 5.4% and 0%, respectively. There was only one embolic complication in cases of PTA or stenting where blocking balloon systems were used. In contrast, distal embolism occurred in 3 of 34 cases of PTA without blocking balloon systems (one symptomatic case) and in 4 of 15 cases of stenting without blocking balloon systems (3 symptomatic cases). Our blocking balloon catheter system is a useful device to reduce the risk of symptomatic distal embolism. PMID:20663375
Excimer laser coronary angioplasty: relative risk analysis of clinical results
NASA Astrophysics Data System (ADS)
Bittl, John A.
1992-08-01
Reports of successful use of excimer laser coronary angioplasty for complex coronary artery disease abound, yet firm indications for its use have not been defined. We attempted to treat 858 coronary stenoses in 764 consecutive patients (mean age 61 years; range 32 - 91 years; 75% men; 76% with Class III or IV angina) with excimer laser angioplasty at 308 nm. Successful treatment was achieved in 86% of patients, as indicated by
A preliminary study of longitudinal neuroadaptation associated with recovery from addiction.
Forster, Sarah E; Finn, Peter R; Brown, Joshua W
2016-11-01
Few studies have explored longitudinal change in event-related brain responses during early recovery from addiction. Moreover, existing findings yield evidence of both increased and decreased signaling within reward and control centers over time. The current study explored reward- and control-related signals in a risky decision-making task and specifically investigated parametric modulations of the BOLD signal, rather than signal magnitude alone. It was hypothesized that risk-related signals during decision-making and outcome evaluation would reflect recovery and that change in specific signals would correspond with improved treatment outcomes. Twenty-one substance dependent individuals were recruited upon enrollment in community-based substance use treatment programs, wherein they received treatment-as-usual. Participants completed functional neuroimaging assessments at baseline and 3-month follow-up while performing the Balloon Analogue Risk Task (BART). Risk- and reward-sensitive signals were identified using parametric modulators. Substance use was tracked throughout the 3-month study interval using the timeline follow-back procedure. Longitudinal contrasts of parametric modulators suggested improved formation of risk-informed outcome expectations at follow-up. Specifically, a greater response to high risk (low-likelihood) positive feedback was identified in caudal anterior cingulate cortex (ACC) and a greater response to low risk (low-likelihood) negative feedback was identified in caudal ACC and inferior frontal gyrus. In addition, attenuation of a ventromedial prefrontal cortex (vmPFC) "reward-seeking" signal (i.e., increasing response with greater reward) during risky decisions at follow-up was associated with less substance use during the study interval. Changes in risk- and reward-related signaling in ACC/vmPFC appear to reflect recovery and may support sobriety. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader
2013-05-31
A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery.
Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader
2014-05-01
A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery.
Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader
2013-01-01
A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery. PMID:23729720
Heidland, U E; Heintzen, M P; Schoppmann, D; Michel, C J; Strauer, B E
2000-02-25
Balloon angioplasty of a stenosed bypass graft has a much higher risk of recurrent stenosis than dilatation of a stenosed native coronary artery. Intracoronary stent implantation has established itself as the better treatment of native coronary artery stenosis than conventional balloon angioplasty. However, there is still uncertainty whether intracoronary stent implantation in stenosed bypass vessels gives better long-term results than conventional balloon angioplasty. Results were retrospectively analyzed of unrandomized 224 primarily successful interventions--122 balloon dilatations and 102 stent implantations--performed between January 1996 and June 1998 on stenosed coronary bypass grafts, re-examined by coronary angiography an average of 6 months later. All but 11 patients were on combined aspirin and ticlopidine antiplatelet aggregation treatment. There was a significantly lower 6-month restenosis rate (30.4%) after stent implantation than after balloon dilatation (51.6%). The re-intervention rate was also significantly lower after stent implantation. These data suggest that stent implantation of stenosed coronary bypass grafts under cover of platelet-aggregation inhibition with aspirin and ticlopidine provides a lower restenosis and thus higher revascularization rate than conventional balloon dilatation.
Percutaneous anterolateral balloon kyphoplasty for metastatic lytic lesions of the cervical spine
Anagnostidis, Kleovoulos S.; AlZeer, Ziad; Kapetanos, George A.
2010-01-01
The purpose of our report is to describe a new application of kyphoplasty, the percutaneous anterolateral balloon kyphoplasty that we performed in two cases of metastatic osteolytic lesions in cervical spine. The first patient, aged 48 years, with primary malignancy in lungs had two metastatic lesions in C2 and C6 vertebrae. Patient’s complaints were about pain and restriction of movements (due to the pain) in the cervical spine. The second patient, aged 70 years, with primary malignancy in stomach, had multiple metastatic lesions in thoracolumbar spine and C3, C4 and C5 vertebrae without neurological symptoms. The main symptoms were from cervical spine with severe pain even in bed rest and systematic use of opiate-base analgesis. The preoperative status was evaluated with X-rays, CT scan, MRI scan and with Karnofsky score and visual analogue pain (VAS) scale. Both patients underwent percutaneous anterolateral balloon kyphoplasty via the anterolateral approach in cervical spine under general anaesthesia. No clinical complications occurred during or after the procedure. Both patients experienced pain relief immediately after balloon kyphoplasty and during the following days. The stiffness also resolved rapidly and cervical collars were removed. VAS score significantly improved from 85 and 95 preoperatively to 30 in both patients. Karnofsky score showed also improvement from 40 and 30 preoperatively to 80 and 70, respectively, at the final follow-up (7 months after the procedure). Fluoroscopy-guided percutaneous anterolateral ballon kyphoplasty proved to be safe and effective minimally invasive procedure for metastatic osteolytic lesions of the cervical spine, reducing pain and avoiding vertebral collapse. Experience and attention are necessary in order to avoid complications. PMID:20499113
2013-01-01
Objective To evaluate the feasibility of the transperineal implementation of biocompatible balloon (Prospace) and the acute toxicity of high dose 3DCRT in patients with localized low risk prostate cancer. Materials and methods Between December 2011 and April 2012, fifteen patients were treated with external 3DCRT consisted of 76–78 Gy in 38–39 daily fractions (2.0 Gy/ fraction). Before 3DCRT, we placed the Prospace though the perineum by a minimally invasive procedure in the intermediate space between the rectum and the prostate. The primary study endpoint was the evaluation of acute toxicity according to the EORTC/RTOG radiation toxicity scale. Erectile function was evaluated with the IIEF-5 questionnaire. Rectosigmoidoscopy was performed at baseline, at the end of 3DCRT and 3 months thereafter in order to assess also the rectal toxicity according to Subjective-RectoSigmoid (S-RS) scale. The evaluation of pain related to Prospace implementation was done with the visual analogue score (VAS). Results The acute toxicities were as follows: grade I GI toxicity in two patients and for GU toxicity, three patients with grade I of nocturia, four patients with grade I of frequency, two patients with grade I and two patients with grade II of dysouria. The mean score of rectal toxicity according to S-RS score was 1.8(±0.6). The mean VAS score related to Prospace was 1.4(±0.5). Erectile function was unchanged. The Prospace device was found stable in sequential CTs during irradiation. Conclusions The implementation of PROSPACE was feasible, while the acute radiation toxicity was low and comparable with IMRT techniques. PMID:23566526
Trande, Paolo; Mussetto, Alessandro; Mirante, Vincenzo G; De Martinis, Elvira; Olivetti, Giampiero; Conigliaro, Rita L; De Micheli, Enrico A
2010-09-01
Overweight and obesity lead to serious health consequences, so that many strategies were recommended for preventing or curing this emerging problem. Treatments are various: diet, physical activity, psychotherapy, drugs, and bariatric surgery. Moreover, during these years, the use of intragastric balloon (BIB) to treat obesity increased rapidly, aimed to (1) reduce bariatric surgical risks; (2) reduce general surgical risks; (3) lead to a significant reduction in the prevalence of cardiovascular diseases, diabetes, musculoskeletal disorders and some cancers. Recently, a new device inflated with air to reduce weight has been developed since 2004 (Heliosphere BAG). Between March 2006 and September 2006, in our unit, intragastric air-filled balloon insertion was performed under general anesthesia and endoscopic control. The balloons were removed after 6 months. We evaluated efficacy, tolerance, and safety of this technique. Seventeen patients (eight men, nine women), with a mean age of 43 +/- 10 years (range 18-65), mean basal BMI of 46 +/- 8 (range 35-58) were included, after providing informed consent. Weight and BMI loss were evaluated in all patients. BMI decreased 4 +/- 3 (range +0.33/-11), weight loss was 11 +/- 9 kg (range +1/-29.5; 8.5%). 14/17 patients maintain a BMI > 35 at the time of balloon removal. The difference between initial weight and BMI was statistically significant (p = 0.02 for weight and p < 0.01 for BMI, T Student test). Tolerance was very good, limited only to some dyspeptic symptoms during the first 3 days after insertion. One asymptomatic gastric ulcer was seen at the removal of balloon. Only one severe adverse effect was registered at the time of insertion (acute coronary syndrome in patient with chronic coronary disease). No serious technical problems were noted at balloon insertion. Balloon removal was more difficult and successful in 15/17 cases (one distal migration and one patient led to surgery because of balloon fragmentation). Intragastric air-filled balloon showed a good profile of efficacy and tolerance. Weight loss appeared to be equivalent to other type of balloons. On the other hand, technical problems (especially at the time of removal) probably linked to the device's material, set a low safety profile.
Abdel-Wahab, Mohamed; Neumann, Franz-Josef; Mehilli, Julinda; Frerker, Christian; Richardt, Doreen; Landt, Martin; Jose, John; Toelg, Ralph; Kuck, Karl-Heinz; Massberg, Steffen; Robinson, Derek R; El-Mawardy, Mohamed; Richardt, Gert
2015-08-18
The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable transcatheter heart valve. The aim of this study was to evaluate clinical and echocardiographic outcome data at longer term follow-up. The investigator-initiated trial randomized 241 high-risk patients with symptomatic severe aortic stenosis and anatomy suitable for treatment with both balloon- and self-expandable transcatheter heart valves to transfemoral transcatheter aortic valve replacement with either device. Patients were followed-up for 1 year, with assessment of clinical outcomes and echocardiographic evaluation of valve function. At 1 year, the rates of death of any cause (17.4% vs. 12.8%; relative risk [RR]: 1.35; 95% confidence interval [CI]: 0.73 to 2.50; p = 0.37) and of cardiovascular causes (12.4% vs. 9.4%; RR: 1.32; 95% CI: 0.63 to 2.75; p = 0.54) were not statistically significantly different in the balloon- and self-expandable groups, respectively. The frequencies of all strokes (9.1% vs. 3.4%; RR: 2.66; 95% CI: 0.87 to 8.12; p = 0.11) and repeat hospitalization for heart failure (7.4% vs. 12.8%; RR: 0.58; 95% CI: 0.26 to 1.27; p = 0.19) did not statistically significantly differ between the 2 groups. Elevated transvalvular gradients during follow-up were observed in 4 patients in the balloon-expandable group (3.4% vs. 0%; p = 0.12); all were resolved with anticoagulant therapy, suggesting a thrombotic etiology. More than mild paravalvular regurgitation was more frequent in the self-expandable group (1.1% vs. 12.1%; p = 0.005). Despite the higher device success rate with the balloon-expandable valve, 1-year follow-up of patients in CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT Trial), with limited statistical power, revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with both balloon- and self-expandable prostheses that were not statistically significantly different. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial; NCT01645202). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Neural activation during risky decision-making in youth at high risk for substance use disorders.
Hulvershorn, Leslie A; Hummer, Tom A; Fukunaga, Rena; Leibenluft, Ellen; Finn, Peter; Cyders, Melissa A; Anand, Amit; Overhage, Lauren; Dir, Allyson; Brown, Joshua
2015-08-30
Risky decision-making, particularly in the context of reward-seeking behavior, is strongly associated with the presence of substance use disorders (SUDs). However, there has been little research on the neural substrates underlying reward-related decision-making in drug-naïve youth who are at elevated risk for SUDs. Participants comprised 23 high-risk (HR) youth with a well-established SUD risk phenotype and 27 low-risk healthy comparison (HC) youth, aged 10-14. Participants completed the balloon analog risk task (BART), a task designed to examine risky decision-making, during functional magnetic resonance imaging. The HR group had faster reaction times, but otherwise showed no behavioral differences from the HC group. HR youth experienced greater activation when processing outcome, as the chances of balloon explosion increased, relative to HC youth, in ventromedial prefrontal cortex (vmPFC). As explosion probability increased, group-by-condition interactions in the ventral striatum/anterior cingulate and the anterior insula showed increasing activation in HR youth, specifically on trials when explosions occurred. Thus, atypical activation increased with increasing risk of negative outcome (i.e., balloon explosion) in a cortico-striatal network in the HR group. These findings identify candidate neurobiological markers of addiction risk in youth at high familial and phenotypic risk for SUDs. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Agyei, Justice O; Alvarez, Cynthia; Iqbal, Azher; Fanous, Andrew A; Siddiqui, Adnan H
2018-06-01
A rare complication following tracheotomy is common carotid artery (CCA) pseudoaneurysm. Treatment modalities for CCA pseudoaneurysm include surgical repair and single-artery balloon-covered stent graft technique. We describe successful treatment of tracheotomy-related CCA pseudoaneurysm with the "kissing balloon" expandable stent graft technique. We successfully implemented the kissing balloon expandable stent graft technique for treatment of a large, narrow-necked, bilobed CCA pseudoaneurysm that arose owing to a tracheotomy complication. The pseudoaneurysm was detected while performing a diagnostic angiogram of the aortic arch and surrounding vessels. The stent was deployed while the 2 balloons were introduced in a kissing manner such that they faced one another to avoid occlusion of either branch of the innominate artery coming into contact; 1 balloon was inflated at the origin of the right subclavian artery, and the other was inflated at the right innominate artery simultaneously. The pseudoaneurysm was successfully contained; normal blood flow was restored in the CCA. The balloons were deflated and withdrawn. The patient remained neurologically intact after the procedure. The kissing balloon technique is a safe and effective alternative to surgical repair, as it prevents morbidities associated with the surgical procedure. Also, this technique decreases the risk of major side-branch occlusion associated with the single-artery balloon-covered stent graft technique. Copyright © 2018 Elsevier Inc. All rights reserved.
Effects of intra-aortic balloon counterpulsation in a model of septic shock.
Solomon, Steven B; Minneci, Peter C; Deans, Katherine J; Feng, Jing; Eichacker, Peter Q; Banks, Steven M; Danner, Robert L; Natanson, Charles; Solomon, Michael A
2009-01-01
Fluid refractory septic shock can develop into a hypodynamic cardiovascular state in both children and adults. Despite management of these patients with empirical inotropic therapy (with or without a vasodilator), mortality remains high. The effect of cardiovascular support using intra-aortic balloon counterpulsation was investigated in a hypodynamic, mechanically ventilated canine sepsis model in which cardiovascular and pulmonary support were titrated based on treatment protocols. Each week, three animals (n = 33, 10-12 kg) were administered intrabronchial Staphylococcus aureus challenge and then randomized to receive intra-aortic balloon counterpulsation for 68 hrs or no intra-aortic balloon counterpulsation (control). Bacterial doses were increased over the study (4-8 x 10(9) cfu/kg) to assess the effects of intra-aortic balloon counterpulsation during sepsis with increasing risk of death. Compared with lower bacterial doses (4-7 x 10(9) colony-forming units/kg), control animals challenged with the highest dose (8 x 10(9) colony-forming units/kg) had a greater risk of death (mortality rate 86% vs. 17%), with worse lung injury ([A - a]O2), and renal dysfunction (creatinine). These sicker animals required higher norepinephrine infusion rates to maintain blood pressure (and higher FIO2) and positive end-expiratory pressure levels to maintain oxygenation (p < or = 0.04 for all). In animals receiving the highest bacterial dose, intra-aortic balloon counterpulsation improved survival time (23.4 +/- 10 hrs longer; p = 0.003) and lowered norepinephrine requirements (0.43 +/- 0.17 microg/kg/min; p = 0.002) and systemic vascular resistance index (1.44 +/- 0.57 dynes/s/cm5/kg; p = 0.0001) compared with controls. Despite these beneficial effects, intra-aortic balloon counterpulsation was associated with an increase in blood urea nitrogen (p = 0.002) and creatinine (p = 0.12). In animals receiving lower doses of bacteria, intra-aortic balloon counterpulsation had no significant effects on survival or renal function. In a canine model of severe septic shock with a low cardiac index, intra-aortic balloon counterpulsation prolongs survival time and lowers vasopressor requirements.
Courtney, Kelly E.; Arellano, Ryan; Barkley-Levenson, Emily; Gálvan, Adriana; Poldrack, Russell A.; MacKillop, James; Jentsch, J. David; Ray, Lara A.
2011-01-01
Background Higher levels of impulsivity have been implicated in the development of alcohol use disorders. Recent findings suggest that impulsivity is not a unitary construct, highlighted by the diverse ways in which the various measures of impulsivity relate to alcohol use outcomes. This study simultaneously tested the following dimensions of impulsivity as determinants of alcohol use and alcohol problems: risky decision-making, self-reported risk attitudes, response inhibition, and impulsive decision-making. Method Participants were a community sample of non-treatment seeking problem drinkers (N = 158). Structural Equation Modeling (SEM) analyses employed behavioral measures of impulsive decision-making (Delay Discounting Task, DDT), response inhibition (Stop Signal Task, SST), and risky decision-making (Balloon Analogue Risk Task, BART), and a self-report measure of risk attitudes (Domain-specific Risk-attitude Scale, DOSPERT), as predictors of alcohol use and of alcohol-related problems in this sample. Results The model fit well, accounting for 38% of the variance in alcohol problems, and identified two impulsivity dimensions that significantly loaded onto alcohol outcomes: (1) impulsive decision-making, indexed by the DDT; and (2) risky decision-making, measured by the BART. Conclusions The impulsive decision-making dimension of impulsivity, indexed by the DDT, was the strongest predictor of alcohol use and alcohol pathology in this sample of problem drinkers. Unexpectedly, a negative relationship was found between risky decision-making and alcohol problems. The results highlight the importance of considering the distinct facets of impulsivity in order to elucidate their individual and combined effects on alcohol use initiation, escalation, and dependence. PMID:22091877
Spiotta, Alejandro M; James, Robert F; Lowe, Stephen R; Vargas, Jan; Turk, Aquilla S; Chaudry, M Imran; Bhalla, Tarun; Janjua, Rashid M; Delaney, John J; Quintero-Wolfe, Stacey; Turner, Raymond D
2015-10-01
Conventional Onyx embolization of cerebral arteriovenous malformations (AVMs) requires lengthy procedure and fluoroscopy times to form an adequate 'proximal plug' which allows forward nidal penetration while preventing reflux and non-targeted embolization. We review our experience with balloon-augmented Onyx embolization of cerebral AVMs using a dual-lumen balloon catheter technique designed to minimize these challenges. Retrospectively acquired data for all balloon-augmented cerebral AVM embolizations performed between 2011 and 2014 were obtained from four tertiary care centers. For each procedure, at least one Scepter C balloon catheter was advanced into the AVM arterial pedicle of interest and Onyx embolization was performed through the inner lumen after balloon inflation via the outer lumen. Twenty patients underwent embolization with the balloon-augmented technique over 24 discreet treatment episodes. There were 37 total arterial pedicles embolized with the balloon-augmented technique, a mean of 1.9 per patient (range 1-5). The treated AVMs were heterogeneous in their location and size (mean 3.3±1.6 cm). Mean fluoroscopy time for each procedure was 48±26 min (28 min per embolized pedicle). Two Scepter C balloon catheter-related complications (8.3% of embolization sessions, 5.4% of pedicles embolized) were observed: an intraprocedural rupture of a feeding pedicle and fracture and retention of a catheter fragment. This multicenter experience represents the largest reported series of balloon-augmented Onyx embolization of cerebral AVMs. The technique appears safe and effective in the treatment of AVMs, allowing more efficient and controlled injection of Onyx with a decreased risk of reflux and decreased fluoroscopy times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Charles Blouin, Mathieu; Bouhout, Ismail; Demers, Philippe; Carrier, Michel; Perrault, Louis; Lamarche, Yoan; El-Hamamsy, Ismail; Bouchard, Denis
2017-05-01
Sutureless aortic valve replacement (AVR) is an emerging alternative to standard AVR in elderly and high-risk patients. This procedure is associated with a high rate of postoperative permanent pacemaker implantation (PPI). The study aim was to assess the impact on the rate of PPI of implanting the Perceval prosthesis without using balloon inflation. A total of 159 patients who underwent sutureless AVR using the Perceval prosthesis was included. Balloon inflation was used in 132 patients (Balloon group) and not used in the remaining 27 (No-Balloon group). Clinical, echocardiographic and electrocardiographic outcomes were assessed. There was no significant difference in PPI rate between the two groups (26% for Balloon group versus 22% in No-Balloon group; p = 0.700). Balloon inflation had no significant impact on the incidence of paravalvular leaks (p = 0.839), or on the need to return to cardiopulmonary bypass (CPB) intraoperatively due to paravalvular leak or unsatisfactory deployment (p >0.999). Mean and peak transaortic pressure gradients were similar between the two groups (p = 0.417 and p = 0.522, respectively). Cross-clamp and CPB times were shorter in the No-Balloon group (49.6 ± 15.9 min versus 61.1 ± 25.6 min and 64.1 ± 26.3 min versus 79.6 ± 35.4 min, respectively; p = 0.027 and p = 0.012, respectively). The two groups had similar postoperative PPI rates. Implanting the Perceval prosthesis without balloon inflation is safe and had no impact on paravalvular leaks, intraoperative complications or hemodynamic results. Reductions in aortic cross-clamp time and CPB time were observed when the balloon was not used.
Saad, Wael E; Nicholson, David B
2013-06-01
Since the conception of balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices 25 years ago, the placement of an indwelling balloon for hours has been central to the BRTO procedure. Numerous variables and variations of the BRTO procedure have been described, including methods to reduce sclerosant, combining percutaneous transhepatic obliteration, varying sclerosant, and using multiple sclerosants within the same procedure. However, the consistent feature of BRTO has always remained the indwelling balloon. Placing an indwelling balloon over hours for the BRTO procedure is a logistical burden that taxes the interventional radiology team and hospital resources. Substituting the balloon with hardware (coils or Amplatzer vascular plugs [AVPs] or both) is technically feasible and its risks most likely correlate with gastrorenal shunt (GRS) size. The current authors use packed 0.018- or 0.035-in coils or both for small gastric variceal systems (GRS size A and B) and AVPs for GRS sizes up to size E (from size A-E). The current authors recommend an indwelling balloon (no hardware substitute) for very large gastric variceal system (GRS size F). Substituting the indwelling balloon for hardware in size F and potentially size E GRS can also be risky. The current article describes the techniques of placing up to 16-mm AVPs through balloon occlusion guide catheters and then deflating the balloon once it has been substituted with the AVPs. In addition, 22-mm AVPs can be placed through sheaths once the balloon occlusion catheters are removed to further augment the 16-mm Amplatzer occlusion. To date, there are no studies describing, let alone evaluating, the clinical feasibility of performing BRTO without indwelling balloons. The described techniques have been successfully performed by the current authors. However, the long-term safety and effectiveness of these techniques is yet to be determined. Copyright © 2013 Elsevier Inc. All rights reserved.
Wang, J; Chung Ann Choo, D; Zhang, X; Yang, Q; Xian, T; Lu, D; Jiang, S
2000-07-01
Spontaneous echo contrast (SEC) is a phenomenon that is commonly seen in areas of blood stasis. It is a slowly moving, cloud-like swirling pattern of "smoke" or increased echogenicity recorded on echocardiography. SEC is commonly seen in the left atrium of patients with mitral stenosis or atrial fibrillation. The presence of SEC has been shown to be a marker of increased thromboembolic risk. By using transesophageal echocardiography during percutaneous balloon mitral valvotomy (PBMV), the study investigated the relationship between SEC and varying left atrial appendage (LAA) blood flow velocity in the human heart. Thirty-five patients with rheumatic mitral stenosis underwent percutaneous balloon mitral valvotomy with intraoperative transesophageal echocardiography monitoring. We alternatively measured LAA velocities and observed the left atrium for various grades of SEC (0 = none to 4 = severe) before and after each balloon inflation. Left atrial appendage maximal ejection velocity was reduced from 35 +/- 14 to 6 +/- 2 mm/s at peak balloon inflation and increased to 40 +/- 16 mm/s after balloon deflation. In comparison with the values before balloon inflation and after balloon deflation, LAA velocities were significantly lower (p < 0.001). New or increased SEC grade was observed during 54 of 61 (88%) inflations and unchanged in 7 (12%) inflations at peak balloon inflation. Spontaneous echo contrast became lower in grade after 55 balloon deflations (90%), completely disappeared after 18 deflations (30%), and remained unchanged after 6 deflations (10%). The mean time to achieve maximal SEC grade (2.5 +/- 1.2 s) coincided with the mean time to trough LAA velocities (2.3 +/- 1.1 s) after balloon inflation. Upon deflation, the mean time to lowest SEC grade (2.9 +/- 1.8 s) coincided with mean time to achieve maximal LAA velocities (2.7 +/- 1.6 s). During balloon inflation, the severity of SEC was enhanced with corresponding reduction in LAA flow velocity. Upon balloon deflation, SEC lightens or disappears with increase in LAA flow velocity.
Potvin, Stéphane; Tikàsz, Andràs; Richard-Devantoy, Stéphane; Lungu, Ovidiu; Dumais, Alexandre
2018-01-01
Despite the high prevalence of suicidal ideas/attempts in schizophrenia, only a handful of neuroimaging studies have examined the neurobiological differences associated with suicide risk in this population. The main objective of the current exploratory study is to examine the neurofunctional correlates associated with a history of suicide attempt in schizophrenia, using a risky decision-making task, in order to show alterations in brain reward regions in this population. Thirty-two male outpatients with schizophrenia were recruited: 13 patients with (SCZ + S) and 19 without a history of suicidal attempt (SCZ - S). Twenty-one healthy men with no history of mental disorders or suicidal attempt/idea were also recruited. Participants were scanned using fMRI while performing the Balloon Analogue Risk Task . A rapid event-related fMRI paradigm was used, separating decision and outcome events, and the explosion probabilities were included as parametric modulators. The most important finding of this study is that SCZ + S patients had reduced activations of the medial prefrontal cortex during the success outcome event (with parametric modulation), relative to both SCZ - S patients and controls, as illustrated by a spatial conjunction analysis. These exploratory results suggest that a history of suicidal attempt in schizophrenia is associated with blunted brain reward activity during emotional decision-making.
Richard-Devantoy, Stéphane; Dumais, Alexandre
2018-01-01
Despite the high prevalence of suicidal ideas/attempts in schizophrenia, only a handful of neuroimaging studies have examined the neurobiological differences associated with suicide risk in this population. The main objective of the current exploratory study is to examine the neurofunctional correlates associated with a history of suicide attempt in schizophrenia, using a risky decision-making task, in order to show alterations in brain reward regions in this population. Thirty-two male outpatients with schizophrenia were recruited: 13 patients with (SCZ + S) and 19 without a history of suicidal attempt (SCZ − S). Twenty-one healthy men with no history of mental disorders or suicidal attempt/idea were also recruited. Participants were scanned using fMRI while performing the Balloon Analogue Risk Task. A rapid event-related fMRI paradigm was used, separating decision and outcome events, and the explosion probabilities were included as parametric modulators. The most important finding of this study is that SCZ + S patients had reduced activations of the medial prefrontal cortex during the success outcome event (with parametric modulation), relative to both SCZ − S patients and controls, as illustrated by a spatial conjunction analysis. These exploratory results suggest that a history of suicidal attempt in schizophrenia is associated with blunted brain reward activity during emotional decision-making. PMID:29686902
Guidelines and Suggestions for Balloon Gondola Design
NASA Technical Reports Server (NTRS)
Franco, Hugo
2017-01-01
This paper discusses the current gondola design requirements for the Columbia Scientific Balloon Facility (CSBF). The CSBF is responsible for launching and supporting balloon borne scientific instruments and has some current updated guidelines that will be discussed in this presentation. As the sophistication of Payload systems have increased in size and complexity new guidelines have been implemented in order to make these instruments stay within the acceptable launch risks. Additionally, there is a requirement to submit a proper stress analysis report that states the flight design requirements have been met. Suggestions are discussed in this presentation that establish the proper guidelines to submit these.
Behavioral preference in sequential decision-making and its association with anxiety.
Zhang, Dandan; Gu, Ruolei
2018-06-01
In daily life, people often make consecutive decisions before the ultimate goal is reached (i.e., sequential decision-making). However, this kind of decision-making has been largely overlooked in the literature. The current study investigated whether behavioral preference would change during sequential decisions, and the neural processes underlying the potential changes. For this purpose, we revised the classic balloon analogue risk task and recorded the electroencephalograph (EEG) signals associated with each step of decision-making. Independent component analysis performed on EEG data revealed that four EEG components elicited by periodic feedback in the current step predicted participants' decisions (gamble vs. no gamble) in the next step. In order of time sequence, these components were: bilateral occipital alpha rhythm, bilateral frontal theta rhythm, middle frontal theta rhythm, and bilateral sensorimotor mu rhythm. According to the information flows between these EEG oscillations, we proposed a brain model that describes the temporal dynamics of sequential decision-making. Finally, we found that the tendency to gamble (as well as the power intensity of bilateral frontal theta rhythms) was sensitive to the individual level of trait anxiety in certain steps, which may help understand the role of emotion in decision-making. © 2018 Wiley Periodicals, Inc.
Holmium:YAG laser coronary angioplasty in patients with lesions not ideal for balloon angioplasty
NASA Astrophysics Data System (ADS)
Miyazaki, Shunichi; Nonogi, Hiroshi; Goto, Yoichi; Itoh, Akira; Ozono, Keizaburo; Daikoku, Satoshi; Haze, Kazuo
1993-06-01
Conventional balloon coronary angioplasty has limitations for application on particular lesions, such as lesions near the left main trunk (LMT), ostial location, and highly eccentric lesions. Hence, efficacy of newly developed Holmium YAG laser coronary angioplasty (HLCA) was assessed for 24 patients with angina. Adjunctive balloon angioplasty was performed for 21 of 24 lesions. Delivered energy ranged from 1.5 to 2.5 watts/pulse and the total exposure time ranged from 6 to 32 seconds. Laser success, defined as 20% reduction of stenotic ratio, was obtained in 16 of 24 (67%) and overall procedural success rate was 92%. Follow up coronary angiography after 3 months showed restenosis in 9 of 19 patients (47%). HLCA is an acutely effective treatment for lesions identified as not ideal for balloon angioplasty. However, angiographical restenosis rate is similar to the conventional balloon angioplasty and a highly calcified complex lesion may not be a candidate for the treatment of HLCA, because of a potential risk of coronary perforation.
Umakanthan, Ramanan; Dubose, Robert; Byrne, John G; Ahmad, Rashid M
2010-10-01
The management of acute myocardial infarction with resultant acute ischemic mitral regurgitation and acute multi-organ failure can prove to be a very challenging scenario. The presence of concomitant vascular disease can only serve to further compromise the complexity of the situation. We demonstrate a new indication for the transthoracic intra-aortic balloon pump as a preoperative means of unloading the heart and improving clinical outcome in such high-risk patients with severe vascular disease. We present the case of a 75-year-old man with a history of severe vascular disease who was transferred emergently to Vanderbilt University Medical Center with an acute inferolateral wall myocardial infarction resulting in severe acute ischemic mitral regurgitation and acute multi-organ failure. He presented with shock liver (serum glutamic-oxaloacetic transaminase [SGOT] of 958), renal failure (creatinine of 3.0), and respiratory failure with a pH of 7.18. Emergent cardiac catheterization revealed 100% occlusion of the left circumflex artery as well as severe ileofemoral disease. The advanced nature of his ileofemoral disease was such that the arterial access catheter occluded the right femoral artery. The duration of time that the catheter was in the artery led to transient limb ischemia with an elevation of his creatine phosphokinase (CPK) to 10,809. Balloon angioplasty followed by stent placement was successfully performed, which restored flow to the coronary vessel. Given the grave nature of the patient's condition, we were very concerned that immediate operative intervention for his condition would entail prohibitively high risk. In fact, the Society of Thoracic Surgeons predicted risk adjusted mortality was calculated to be 56%. In order to minimize patient mortality and morbidity, it was critical to help restore perfusion and organ recovery. Therefore, we decided that the chances for this patient's survival would improve if his condition could be optimized by placement of an intra-aortic balloon pump before undergoing surgery. Given the limb ischemia following arterial sheath insertion, femoral placement of an intra-aortic balloon pump was not an option. Placement of the intra-aortic balloon pump was attempted via a left subclavian artery cutdown, but was not successful. Therefore, a sternotomy was performed, and we placed a transthoracic intra-aortic balloon pump in order to stabilize the patient's hemodynamics and allow for organ recovery. The patient showed immediate improvement, and 4 days later, the multi-organ failure resolved and he successfully underwent mitral valve replacement. The patient was ultimately discharged to a local rehabilitation facility in satisfactory condition. This case demonstrates the utility of a transthoracic intra-aortic balloon pump as a preoperative means of stabilization in very high risk patients with severe peripheral vascular disease in whom the conventional approaches are not possible.
Repka, Michael X; Chandler, Danielle L; Holmes, Jonathan M; Hoover, Darren L; Morse, Christine L; Schloff, Susan; Silbert, David I; Tien, D Robbins
2009-05-01
To compare the outcomes of balloon catheter dilation and nasolacrimal intubation as treatment for congenital nasolacrimal duct obstruction after failed probing in children younger than 4 years. We conducted a prospective, nonrandomized, multicenter study that enrolled 159 children aged 6 months to younger than 48 months who had a history of a single failed nasolacrimal duct probing and at least 1 of the following clinical signs of nasolacrimal duct obstruction: epiphora, mucous discharge, or increased tear lake. One hundred ninety-nine eyes underwent either balloon catheter nasolacrimal duct dilation or nasolacrimal duct intubation. Treatment success was defined as absence of epiphora, mucous discharge, or increased tear lake at the outcome visit 6 months after surgery. Treatment success was reported in 65 of 84 eyes (77%; 95% confidence interval, 65%-85%) in the balloon catheter dilation group compared with 72 of 88 eyes (84% after adjustment for intereye correlation; 74%-91%) in the nasolacrimal intubation group (risk ratio for success for intubation vs balloon dilation, 1.08; 0.95-1.22). Both balloon catheter dilation and nasolacrimal duct intubation alleviate the clinical signs of persistent nasolacrimal duct obstruction in a similar percentage of patients.
The Balloon Analog Insurance Task (BAIT): A Behavioral Measure of Protective Risk Management
Essex, Brian G.; Lejuez, Carl W.; Qian, Rebecca Y.; Bernstein, Katherine; Zald, David H.
2011-01-01
Prior methods used to assess individual differences related to risk have not focused on an important component of risk management: how willing individuals are to pay for or take actions to insure what they already have. It is not clear whether this type of protective risk management taps into the same individual differences as does risk taking propensity measured by existing risk taking tasks. We developed a novel task to assess protective risk management, the Balloon Analog Insurance Task (BAIT), which is modeled after the Balloon Analog Risk Task (BART). In the BAIT, individuals are forced to decide how much money they are willing to pay in order to insure a specific fraction of their prior winnings given changing but imprecise levels of risk of monetary loss. Participants completed the BART and BAIT for real monetary rewards, and completed six self report questionnaires. The amount of insurance purchased on the BAIT was positively correlated with scores on the Intolerance of Uncertainty Scale and on the Checking scale of the revised Obsessive Compulsive Inventory. Conversely, the amount of insurance purchased was negatively correlated with scores on the Domain Specific Risk Taking Questionnaire, and on the Psychopathic Personality Inventory (PPI). Furthermore, relationships between insurance purchased and these scales remained significant after controlling for the BART in linear regression analyses, and the BART was only a significant predictor for measures on one scale - the PPI. Our results reveal that behavior on the BAIT taps into a number of individual differences that are not related to behavior on another measure of risk taking. We propose that the BAIT may provide a useful complement to the BART in the assessment of risk management style. PMID:21738666
The Balloon Analog Insurance Task (BAIT): a behavioral measure of protective risk management.
Essex, Brian G; Lejuez, Carl W; Qian, Rebecca Y; Bernstein, Katherine; Zald, David H
2011-01-01
Prior methods used to assess individual differences related to risk have not focused on an important component of risk management: how willing individuals are to pay for or take actions to insure what they already have. It is not clear whether this type of protective risk management taps into the same individual differences as does risk taking propensity measured by existing risk taking tasks. We developed a novel task to assess protective risk management, the Balloon Analog Insurance Task (BAIT), which is modeled after the Balloon Analog Risk Task (BART). In the BAIT, individuals are forced to decide how much money they are willing to pay in order to insure a specific fraction of their prior winnings given changing but imprecise levels of risk of monetary loss. Participants completed the BART and BAIT for real monetary rewards, and completed six self report questionnaires. The amount of insurance purchased on the BAIT was positively correlated with scores on the Intolerance of Uncertainty Scale and on the Checking scale of the revised Obsessive Compulsive Inventory. Conversely, the amount of insurance purchased was negatively correlated with scores on the Domain Specific Risk Taking Questionnaire, and on the Psychopathic Personality Inventory (PPI). Furthermore, relationships between insurance purchased and these scales remained significant after controlling for the BART in linear regression analyses, and the BART was only a significant predictor for measures on one scale--the PPI. Our results reveal that behavior on the BAIT taps into a number of individual differences that are not related to behavior on another measure of risk taking. We propose that the BAIT may provide a useful complement to the BART in the assessment of risk management style.
Humphreys, Kathryn L; Telzer, Eva H; Flannery, Jessica; Goff, Bonnie; Gabard-Durnam, Laurel; Gee, Dylan G; Lee, Steve S; Tottenham, Nim
2016-02-01
Decision making in the context of risk is a complex and dynamic process that changes across development. Here, we assessed the influence of sensitivity to negative feedback (e.g., loss) and learning on age-related changes in risky decision making, both of which show unique developmental trajectories. In the present study, we examined risky decision making in 216 individuals, ranging in age from 3-26 years, using the balloon emotional learning task (BELT), a computerized task in which participants pump up a series of virtual balloons to earn points, but risk balloon explosion on each trial, which results in no points. It is important to note that there were 3 balloon conditions, signified by different balloon colors, ranging from quick- to slow-to-explode, and participants could learn the color-condition pairings through task experience. Overall, we found age-related increases in pumps made and points earned. However, in the quick-to-explode condition, there was a nonlinear adolescent peak for points earned. Follow-up analyses indicated that this adolescent phenotype occurred at the developmental intersection of linear age-related increases in learning and decreases in sensitivity to negative feedback. Adolescence was marked by intermediate values on both these processes. These findings show that a combination of linearly changing processes can result in nonlinear changes in risky decision making, the adolescent-specific nature of which is associated with developmental improvements in learning and reduced sensitivity to negative feedback. (c) 2016 APA, all rights reserved).
Mattei, Tobias A
2017-06-01
Previous studies have demonstrated lower rates of cement extravasation when comparing balloon kyphoplasty with vertebroplasty, an effect attributed to the low-pressure injection. However, in patients with isolated endplate fractures, balloon kyphoplasty may lead to further endplate damage and increased risks of intradiscal extravasation. The author provides a stepwise description of a new technique called cavitational kyphoplasty that allows targeted low-pressure cement injection without the necessity of balloon inflation. The new technique of cavitational kyphoplasty has been shown to be specially useful in patients with isolated endplate fractures without significant loss of the vertebral body height.
Kohno, Milky; Nurmi, Erika L; Laughlin, Christopher P; Morales, Angelica M; Gail, Emma H; Hellemann, Gerhard S; London, Edythe D
2016-02-01
Brain imaging has revealed links between prefrontal activity during risky decision-making and striatal dopamine receptors. Specifically, striatal dopamine D2-like receptor availability is correlated with risk-taking behavior and sensitivity of prefrontal activation to risk in the Balloon Analogue Risk Task (BART). The extent to which these associations, involving a single neurochemical measure, reflect more general effects of dopaminergic functioning on risky decision making, however, is unknown. Here, 65 healthy participants provided genotypes and performed the BART during functional magnetic resonance imaging. For each participant, dopamine function was assessed using a gene composite score combining known functional variation across five genes involved in dopaminergic signaling: DRD2, DRD3, DRD4, DAT1, and COMT. The gene composite score was negatively related to dorsolateral prefrontal cortical function during risky decision making, and nonlinearly related to earnings on the task. Iterative permutations of all possible allelic variations (7777 allelic combinations) was tested on brain function in an independently defined region of the prefrontal cortex and confirmed empirical validity of the composite score, which yielded stronger association than 95% of all other possible combinations. The gene composite score also accounted for a greater proportion of variability in neural and behavioral measures than the independent effects of each gene variant, indicating that the combined effects of functional dopamine pathway genes can provide a robust assessment, presumably reflecting the cumulative and potentially interactive effects on brain function. Our findings support the view that the links between dopaminergic signaling, prefrontal function, and decision making vary as a function of dopamine signaling capacity.
Bupropion improves attention but does not affect impulsive behavior in healthy young adults.
Acheson, Ashley; de Wit, Harriet
2008-04-01
Bupropion is an effective abstinence aid for cessation of smoking and possibly other drug use as well. There is evidence that bupropion improves attention and impulse control in certain patient populations, and improvements in these processes could mediate its efficacy as an abstinence aid. In the present study, we tested the effects of acute bupropion on measures of attention and impulsivity in healthy adults with d-amphetamine included as a positive control. Twenty-two nonsmokers (11 women) and 11 smokers (4 women) completed four 4-hr sessions where they received placebo, bupropion (150 or 300 mg), or d-amphetamine (20 mg) in capsules. Ninety minutes after capsule administration, participants were tested on attention with a simple reaction time task (SRT) and on impulsivity with the stop task, a delay and probability discounting task (DPD), and the balloon analogue risk task (BART). Participants also completed mood questionnaires during sessions. Bupropion (150 mg) decreased lapses in attention on the SRT, but did not affect performance on the stop task, DPD, or BART. Amphetamine decreased lapses in attention and speeded sensory motor processing time on the SRT but did not significantly affect responding on the stop task or DPD. On the BART, d-amphetamine tended to decrease risk taking in men but increased risk taking in women. Bupropion (300 mg) and d-amphetamine increased ratings of arousal. These results suggest that bupropion improves attention without affecting impulsive behavior in healthy adults. Improvements in attention may contribute to the effectiveness of bupropion as a pharmacotherapy for smoking.
Bupropion improves attention but does not affect impulsive behavior in healthy young adults
Acheson, Ashley; de Wit, Harriet
2014-01-01
Bupropion is an effective abstinence aid for cessation of smoking and possibly other drug use as well. There is evidence that bupropion improves attention and impulse control in certain patient populations, and improvements in these processes could mediate its efficacy as an abstinence aid. In the present study, we tested the effects of acute bupropion on measures of attention and impulsivity in healthy adults with d-amphetamine included as a positive control. Twenty-two nonsmokers (11 women) and 11 smokers (4 women) completed four 4-h sessions where they received placebo, bupropion (150 or 300 mg) or d-amphetamine (20 mg) in capsules. Ninety minutes after capsule administration, participants were tested on attention with a Simple Reaction Time Task (SRT) and on impulsivity with the Stop Task, a Delay and Probability Discounting Task (DPD), and the Balloon Analogue Risk Task (BART). Participants also completed mood questionnaires during sessions. Bupropion (150 mg) decreased lapses in attention on the SRT, but did not affect performance on the Stop Task, DPD or BART. d-Amphetamine decreased lapses in attention and speeded sensory motor processing time on the SRT but did not significantly affect responding on the Stop Task or DPD. On the BART, d-amphetamine tended to decrease risk taking in men but increased risk taking in women. Bupropion (300 mg) and d-amphetamine increased ratings of arousal. These results suggest that bupropion improves attention without affecting impulsive behavior in healthy adults. Improvements in attention may contribute to the effectiveness of bupropion as a pharmacotherapy for smoking. PMID:18489015
Schweizer, Tina; Schmitz, Julian; Plempe, Laura; Sun, Dali; Becker-Asano, Christian; Leonhart, Rainer; Tuschen-Caffier, Brunna
2017-01-01
Dysfunctional processing of traumatic events may be in particular related to high trait anxiety as a pre-traumatic risk factor for the development of post-traumatic stress disorder (PTSD). However, as this has rarely been investigated in prospective, experimental studies, we aimed to analyse the association between high trait anxiety and affective as well as cognitive processing of stress using a new prospective Virtual Reality analogue trauma paradigm to overcome limitations of retrospective or current analogue designs. Individuals with high and low trait anxiety (N = 80) were exposed to a multi-sensory Virtual Reality emergency scenario while psychophysiological stress response, emotion regulation and intrusive memories were assessed. Our results showed that high trait anxiety individuals display increased (i) subjective stress responses, (ii) emotion dysregulation and (iii) intrusive memories upon VR analogue trauma exposure. In particular, our sample of high trait anxiety individuals displayed limited access to different emotion regulation strategies as well as increased worry and rumination regarding perceived intrusive memories. Considering the complex interplay of multiple risk factors, our findings suggests that peri-traumatic affective processing seems to mediate high trait anxiety and post-traumatic intrusive memories thereby pointing out the central role of peri-traumatic processes for intrusion development. In addition, HA as a modulating pre-traumatic risk factor might further increase the risk of later dysfunctional processing of an analogue trauma by interacting with factors of affective processing during analogue trauma exposure. Implications of these findings which may contribute to a higher risk to develop PTSD are discussed.
Schmitz, Julian; Plempe, Laura; Sun, Dali; Becker-Asano, Christian; Leonhart, Rainer; Tuschen-Caffier, Brunna
2017-01-01
Dysfunctional processing of traumatic events may be in particular related to high trait anxiety as a pre-traumatic risk factor for the development of post-traumatic stress disorder (PTSD). However, as this has rarely been investigated in prospective, experimental studies, we aimed to analyse the association between high trait anxiety and affective as well as cognitive processing of stress using a new prospective Virtual Reality analogue trauma paradigm to overcome limitations of retrospective or current analogue designs. Individuals with high and low trait anxiety (N = 80) were exposed to a multi-sensory Virtual Reality emergency scenario while psychophysiological stress response, emotion regulation and intrusive memories were assessed. Our results showed that high trait anxiety individuals display increased (i) subjective stress responses, (ii) emotion dysregulation and (iii) intrusive memories upon VR analogue trauma exposure. In particular, our sample of high trait anxiety individuals displayed limited access to different emotion regulation strategies as well as increased worry and rumination regarding perceived intrusive memories. Considering the complex interplay of multiple risk factors, our findings suggests that peri-traumatic affective processing seems to mediate high trait anxiety and post-traumatic intrusive memories thereby pointing out the central role of peri-traumatic processes for intrusion development. In addition, HA as a modulating pre-traumatic risk factor might further increase the risk of later dysfunctional processing of an analogue trauma by interacting with factors of affective processing during analogue trauma exposure. Implications of these findings which may contribute to a higher risk to develop PTSD are discussed. PMID:29287111
Zhang, Qun; Lin, Shi-Rong; He, Fang; Kang, De-Hua; Chen, Guo-Zhang; Luo, Wei
2011-11-01
Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volumes and normal tissues in postoperative intensity-modulated radiotherapy (IMRT) after placing a water-filled balloon into the resection cavity. Three postoperative patients with advanced maxillary sinus carcinoma were selected in this trial. Water-filled balloons and supporting dental stents were fabricated according to the size of the maxillary resection cavity. Simulation CT scans were performed with or without water-filled balloons, IMRT treatment plans were established, and dose distribution to target volumes and organs at risk were evaluated. Compared to those in the treatment plan without balloons, the dose (D98) delivered to 98% of the gross tumor volume (GTV) increased by 2.1 Gy (P = 0.009), homogeneity index (HI) improved by 2.3% (P = 0.001), and target volume conformity index (TCI) of 68 Gy increased by 18.5% (P = 0.011) in the plan with balloons. Dosimetry endpoints of normal tissues around target regions in both plans were not significantly different (P > 0.05) except for the optic chiasm. In the plan without balloons, 68 Gy high-dose regions did not entirely cover target volumes in the ethmoid sinus, posteromedial wall of the maxillary sinus, or surgical margin of the hard palate. In contrast, 68 Gy high-dose regions entirely covered the GTV in the plan with balloons. These results suggest that placing a water-filled balloon in the resection cavity for postoperative IMRT of maxillary sinus carcinoma can reduce low-dose regions and markedly and simultaneously increase dose homogeneity and conformity of target volumes.
[The Application of Internal Iliac Artery Balloon Occlusion in Pernicious Placenta Previa].
Qi, Xiao-Rong; Liu, Xing-Hui; You, Yong; Wang, Xiao-Dong; Zhou, Rong; Xing, Ai-Yun; Zhang, Li; Ning, Gang; Zhao, Fu-Min; Li, Kai-Ming
2016-07-01
To evaluate the clinical application value of internal iliac artery balloon occlusion in pernicious placenta previa. We retrospectively reviewed the medical records of the patients of pernicious placenta previa in a single center from Jan, 2010 to Jan, 2015. The patients were divided into two groups, internal iliac artery balloon occlusion group and the control group without endovascular intervention. Blood loss in operation, volume of transfused blood products, caesarean hysterectomy, operating time, hospital days after operation and postoperative morbidity were compared between the two groups. The balloon occlusion group had significantly less blood loss, the volume of transfused blood products, caesarean hysterectomy, hospital day after operation than the control group had. There was no statistical difference in operating time, intensive care units (ICU), hypotension, infection, hypoxemia, bladder injury, bowel obstruction, neonatal asphyxia between the two groups. The balloon occlusion group had significantly higher rate in coagulopathy, hypoalbuminemia, electrolyte imbalance. Among the patients whose uterus were preserved, the blood loss was not significantly difference between the two groups. Among the patients with the complication of placenta accreta, caesarean hysterectomy was less in balloon group, and blood loss between the two groups was not significantly different. Among the patients without placenta accrete, the blood loss was less in balloon group, and caesarean hysterectomy between the two groups was not significantly different. The risk of hysterectomy in balloon group was related to placenta accreta, uterine arteries engorgement, placental invasive serosa, taking placenta by hand, placental invasive bladder, barrel-shaped thickening of lower uterine segment, unable to remove placenta. Internal iliac artery balloon occlusion is an effective treatment for pernicious placenta previa.
Bipolar versus balloon endometrial ablation in the office: a randomized controlled trial.
Penninx, Josien P M; Herman, Malou C; Kruitwagen, Roy F P M; Ter Haar, Annette J F; Mol, Ben W; Bongers, Marlies Y
2016-01-01
To compare the effectiveness of bipolar radiofrequency (Novasure®) ablation and balloon endometrial ablation (Thermablate®). We performed a multi-center double blind, randomized controlled trial in three hospitals in The Netherlands. Women with heavy menstrual bleeding were randomly allocated to bipolar or balloon endometrial ablation, performed in the office, using a paracervical block. The primary outcome was amenorrhea. Secondary outcome measures were pain, satisfaction, quality of life and reintervention. 104 women were randomized into the bipolar (52) and balloon (52) groups. After 12 months amenorrhea rates were 56% (29/52) in the bipolar group and 23% (12/52) in the balloon group (relative risk (RR) 0.6, 95% confidence interval (CI) 0.4-0.8). The mean visual analog pain score of the total procedure was 7.1 in the bipolar group and 7.4 in the balloon group (P<.577). 87% (45/52) of the patients in the bipolar group were satisfied with the result of the treatment versus 69% (36/52) in the balloon group (RR 0.44, 95% CI 0.2-0.97). The reintervention rates were 5/52 (10%) in the bipolar group and 6/52 (12%) in the balloon group (RR 1.02, 95% CI 0.9-1.2). Quality of life (Shaw score) improved over time (P<.001) and was significantly higher in the bipolar group at 12 months follow-up (P=.025). In the treatment of heavy menstrual bleeding, bipolar radiofrequency endometrial ablation is superior to balloon endometrial ablation as an office procedure in amenorrhea rate, patient satisfaction and quality of life. Copyright © 2015. Published by Elsevier Ireland Ltd.
Cheuk, Queenie K Y; Lo, T K; Lee, C P; Yeung, Anita P C
2015-06-01
To evaluate the efficacy and safety of double balloon catheter for induction of labour in Chinese women with one previous caesarean section and unfavourable cervix at term. Retrospective cohort study. A regional hospital in Hong Kong. Women with previous caesarean delivery requiring induction of labour at term and with an unfavourable cervix from May 2013 to April 2014. Primary outcome was to assess rate of successful vaginal delivery (spontaneous or instrument-assisted) using double balloon catheter. Secondary outcomes were double balloon catheter induction-to-delivery and removal-to-delivery interval; cervical score improvement; oxytocin augmentation; maternal or fetal complications during cervical ripening, intrapartum and postpartum period; and risk factors associated with unsuccessful induction. All 24 Chinese women tolerated double balloon catheter well. After double balloon catheter expulsion or removal, the cervix successfully ripened in 18 (75%) cases. The improvement in Bishop score 3 (interquartile range, 2-4) was statistically significant (P<0.001). Overall, 18 (75%) cases were delivered vaginally. The median insertion-to-delivery and removal-to-delivery intervals were 19 (interquartile range, 13.4-23.0) hours and 6.9 (interquartile range, 4.1-10.8) hours, respectively. Compared with cases without, the interval to delivery was statistically significantly shorter in those with spontaneous balloon expulsion or spontaneous membrane rupture during ripening (7.8 vs 3.0 hours; P=0.025). There were no major maternal or neonatal complications. The only factor significantly associated with failed vaginal birth after caesarean was previous caesarean section for failure to progress (P<0.001). This is the first study using double balloon catheter for induction of labour in Asian Chinese women with previous caesarean section. Using double balloon catheter, we achieved a vaginal birth after caesarean rate of 75% without major complications.
Byrnes, Nadia K.; Hayes, John E.
2016-01-01
Based on work a quarter century ago, it is widely accepted personality traits like sensation seeking are related to the enjoyment and intake of spicy foods; however, data supporting this belief is actually quite limited. Recently, we reported strong to moderate correlations between remembered spicy food liking and two personality traits measured with validated questionnaires. Here, participants consumed capsaicin-containing strawberry jelly to generate acute estimates of spicy food liking. Additionally, we used a laboratory-based behavioral measure of risk taking (the momentary Balloon Analogue Risk Task; mBART) to complement a range of validated self-report measures of risk-related personality traits. Present data confirm Sensation Seeking correlates with overall spicy meal liking and liking of the burn of a spicy meal, and extends prior findings by showing novel correlations with the liking of sampled stimuli. Other personality measures, including Sensitivity to Punishment (SP), Sensitivity to Reward (SR), and the Impulsivity and Risk Taking subscales of the DSM5 Personality Inventory (PID5) did not show significant relationships with liking of spicy foods, either sampled or remembered. Our behavioral risk taking measure, the mBART, also failed to show a relationship with remembered or sampled liking. However, significant relationships were observed between reported intake of spicy foods and Sensitivity to Reward, and the Risk Taking subscale of the PID-5 (PID5-RT). Based on the observed patterns among various personality measures, and spicy food liking and intake, we propose that personality measures may exert their influence on intake of spicy food via different mechanisms. We also speculate that Sensation Seeking may reflect motivations for consuming spicy foods that are more intrinsic, while the motivations for eating spicy foods measured by SR and PID5-RT may be more extrinsic. PMID:27137410
Byrnes, Nadia K; Hayes, John E
2016-08-01
Based on work a quarter century ago, it is widely accepted personality traits like sensation seeking are related to the enjoyment and intake of spicy foods; however, data supporting this belief is actually quite limited. Recently, we reported strong to moderate correlations between remembered spicy food liking and two personality traits measured with validated questionnaires. Here, participants consumed capsaicin-containing strawberry jelly to generate acute estimates of spicy food liking. Additionally, we used a laboratory-based behavioral measure of risk taking (the mobile Balloon Analogue Risk Task; mBART) to complement a range of validated self-report measures of risk-related personality traits. Present data confirm Sensation Seeking correlates with overall spicy meal liking and liking of the burn of a spicy meal, and extends prior findings by showing novel correlations with the liking of sampled stimuli. Other personality measures, including Sensitivity to Punishment (SP), Sensitivity to Reward (SR), and the Impulsivity and Risk Taking subscales of the DSM5 Personality Inventory (PID-5) did not show significant relationships with liking of spicy foods, either sampled or remembered. Our behavioral risk taking measure, the mBART, also failed to show a relationship with remembered or sampled liking. However, significant relationships were observed between reported intake of spicy foods and Sensitivity to Reward, and the Risk Taking subscale of the PID-5 (PID5-RT). Based on the observed patterns among various personality measures, and spicy food liking and intake, we propose that personality measures may exert their influence on intake of spicy food via different mechanisms. We also speculate that Sensation Seeking may reflect motivations for consuming spicy foods that are more intrinsic, while the motivations for eating spicy foods measured by SR and PID5-RT may be more extrinsic. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lin, Zi-Jing; Li, Lin; Cazzell, Marry; Liu, Hanli
2013-03-01
Functional near-infrared spectroscopy (fNIRS) is a non-invasive imaging technique which measures the hemodynamic changes that reflect the brain activity. Diffuse optical tomography (DOT), a variant of fNIRS with multi-channel NIRS measurements, has demonstrated capability of three dimensional (3D) reconstructions of hemodynamic changes due to the brain activity. Conventional method of DOT image analysis to define the brain activation is based upon the paired t-test between two different states, such as resting-state versus task-state. However, it has limitation because the selection of activation and post-activation period is relatively subjective. General linear model (GLM) based analysis can overcome this limitation. In this study, we combine the 3D DOT image reconstruction with GLM-based analysis (i.e., voxel-wise GLM analysis) to investigate the brain activity that is associated with the risk-decision making process. Risk decision-making is an important cognitive process and thus is an essential topic in the field of neuroscience. The balloon analogue risk task (BART) is a valid experimental model and has been commonly used in behavioral measures to assess human risk taking action and tendency while facing risks. We have utilized the BART paradigm with a blocked design to investigate brain activations in the prefrontal and frontal cortical areas during decision-making. Voxel-wise GLM analysis was performed on 18human participants (10 males and 8females).In this work, we wish to demonstrate the feasibility of using voxel-wise GLM analysis to image and study cognitive functions in response to risk decision making by DOT. Results have shown significant changes in the dorsal lateral prefrontal cortex (DLPFC) during the active choice mode and a different hemodynamic pattern between genders, which are in good agreements with published literatures in functional magnetic resonance imaging (fMRI) and fNIRS studies.
Diamantopoulos, A; Katsanos, K
2014-10-01
A systematic review was performed to provide a qualitative analysis and quantitative data synthesis of randomized controlled trials (RCTs) assessing debulking atherectomy versus balloon angioplasty for treatment of femoropopliteal artery occlusive disease. PubMed (MEDLINE), EMBASE, AMED, Scopus, online content and meeting abstracts were searched in May 2014 for eligible RCTs following the PRISMA selection process. Risk of bias was assessed using the Cochrane Collaboration's tool. Pooled risks were calculated with a random effects model to account for clinical and conceptual heterogeneity. Sensitivity analysis was employed to test the robustness of the results. Six RCTs comprising 287 patients (328 lesions) treated with either debulking atherectomy or balloon angioplasty for femoropopliteal artery disease were analyzed and synthesized. Technical success was similar between the atherectomy and the angioplasty group (93.6% vs. 96.2%, RR: 0.99. 95%CI: 0.95-1.03, P=0.57, I(2)=0%). Need for bail-out stenting and distal arterial embolization were largely similar between atherectomy and balloon angioplasty alone. After a median follow-up of 9 months the 2 groups showed similar primary patency (RR: 0.90, 95%CI: 0.56-1.46, P=0.68, I(2)=69%). Only 2 low-quality studies reported amputation and mortality rates, both of which were found significantly less in the atherectomy arms. Analysis of a limited body of low quality evidence with high risk of bias showed that debulking atherectomy of the femoropopliteal artery does not seem to confer any procedural advantage or improvement of clinical outcomes over balloon angioplasty alone.
Lee, Teng-Yu; Hsu, Yao-Chun; Yu, Shi-Hang; Lin, Jaw-Town; Wu, Ming-Shiang; Wu, Chun-Ying
2018-06-01
Chronic infection with hepatitis B virus (HBV) increases risk of intrahepatic cholangiocarcinoma (ICC), but it is not clear whether antiviral therapy reduces risk. We investigated the association between nucleos(t)ide analogue therapy and ICC risk. We performed a nationwide long-term cohort study using Taiwan's National Health Insurance Research Database to obtain data on 185,843 patients with chronic HBV infection from October 1, 2003 through December 31, 2012. We excluded patients with confounding disorders such as infection with hepatitis C virus, HIV, or other hepatitis-associated viruses; liver flukes; biliary stone diseases; cholangitis; congenital biliary anomalies; biliary tract surgeries; or cancer. We identified 10,062 patients who received nucleos(t)ide analogue therapy (the treated group), and used propensity scores to match them (1:1) with patients who received hepatoprotectants (the untreated group). Cumulative incidences of and hazard ratios (HRs) for ICC development were analyzed. The cumulative incidence of ICC was significantly lower in the treated group after 3 years of therapy (1.28%; 95% CI, 0.56-2.01) than in the untreated group (3.14%; 95% CI, 2.02-4.27) and after 5 years of therapy (1.53%; 95% CI, 0.73-2.33 vs 4.32% in untreated group; 95% CI, 2.96-5.6869). In multivariable regression analysis, nucleos(t)ide analogue therapy was independently associated with a reduced risk of ICC (HR, 0.44; 95% CI, 0.25-0.78; P = .005). Older age (HR 1.05 per year; 95% CI, 1.03-1.07) and cirrhosis (HR, 2.80; 95% CI, 1.52-5.1415) were independently associated with an increased risk of ICC. Sensitivity analyses verified the association between nucleos(t)ide analogue therapy and a reduced ICC risk. A nationwide long-term cohort study in Taiwan showed that nucleos(t)ide analogue therapy for chronic HBV infection is significantly associated with a reduced ICC risk. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
[Obstruction of the nasal passage caused by a balloon catheter in a calf].
Rijkenhuizen, A B
1993-01-01
Decompression of the rumen as a supporting symptomatic therapy of recurrent bloat in calves and juvenile cattle is used regularly. The gas should be released for several days. This is facilitated by the use of a balloon stomach tube, which can be left in situ for up to five days. However, the use of this tube is not always without risks, which will be discussed on base of a patient.
Panwar, Karni; Rutherford, Helena J V; Mencl, W Einar; Lacadie, Cheryl M; Potenza, Marc N; Mayes, Linda C
2014-11-01
Increased impulsivity and risk-taking are common during adolescence and relate importantly to addictive behaviors. However, the extent to which impulsivity and risk-taking relate to brain activations that mediate cognitive processing is not well understood. Here we examined the relationships between impulsivity and risk-taking and the neural correlates of working memory. Neural activity was measured in 18 adolescents (13-18 years) while they engaged in a working memory task that included verbal and visuospatial components that each involved encoding, rehearsal and recognition stages. Risk-taking and impulsivity were assessed using the Balloon Analogue Risk Task (BART) and the adolescent version of the Barratt Impulsiveness Scale-11 (BIS-11A), respectively. We found overlapping as well as distinct regions subserving the different stages of verbal and visuospatial working memory. In terms of risk-taking, we found a positive correlation between BART scores and activity in subcortical regions (e.g., thalamus, dorsal striatum) recruited during verbal rehearsal, and an inverse correlation between BART scores and cortical regions (e.g., parietal and temporal regions) recruited during visuospatial rehearsal. The BIS-11A evidenced that motor impulsivity was associated with activity in regions recruited during all stages of working memory, while attention and non-planning impulsivity was only associated with activity in regions recruited during recognition. In considering working memory, impulsivity and risk-taking together, both impulsivity and risk-taking were associated with activity in regions recruited during rehearsal; however, during verbal rehearsal, differential correlations were found. Specifically, positive correlations were found between: (1) risk-taking and activity in subcortical regions, including the thalamus and dorsal striatum; and, (2) motor impulsivity and activity in the left inferior frontal gyrus, insula, and dorsolateral prefrontal cortex. Therefore these findings suggest that while there may be some overlap in the neural correlates of working memory and their relationship to impulsivity and risk-taking, there are also important differences in these constructs and their relationship to the stages of working memory during adolescence. Copyright © 2013 Elsevier Ltd. All rights reserved.
Panwar, Karni; Rutherford, Helena J.V.; Mencl, W. Einar; Lacadie, Cheryl M.; Potenza, Marc N.; Mayes, Linda C.
2014-01-01
Increased impulsivity and risk-taking are common during adolescence and relate importantly to addictive behaviors. However, the extent to which impulsivity and risk-taking relate to brain activations that mediate cognitive processing is not well understood. Here we examined the relationships between impulsivity and risk-taking and the neural correlates of working memory. Neural activity was measured in 18 adolescents (13–18 years) while they engaged in a working memory task that included verbal and visuospatial components that each involved encoding, rehearsal and recognition stages. Risk-taking and impulsivity were assessed using the Balloon Analogue Risk Task (BART) and the adolescent version of the Barratt Impulsiveness Scale -11 (BIS-11A), respectively. We found overlapping as well as distinct regions subserving the different stages of verbal and visuospatial working memory. In terms of risk-taking, we found a positive correlation between BART scores and activity in subcortical regions (e.g., thalamus, dorsal striatum) recruited during verbal rehearsal, and an inverse correlation between BART scores and cortical regions (e.g., parietal and temporal regions) recruited during visuospatial rehearsal. The BIS-11A evidenced that motor impulsivity was associated with activity in regions recruited during all stages of working memory, while attention and non-planning impulsivity was only associated with activity in regions recruited during recognition. In considering working memory, impulsivity and risk-taking together, both impulsivity and risk-taking were associated with activity in regions recruited during rehearsal; however, during verbal rehearsal, differential correlations were found. Specifically, positive correlations were found between: (1) risk-taking and activity in subcortical regions, including the thalamus and dorsal striatum; and, (2) motor impulsivity and activity in the left inferior frontal gyrus, insula, dorsolateral and ventrolateral prefrontal cortex. Therefore these findings suggest that while there may be some overlap in the neural correlates of working memory and their relationship to impulsivity and risk-taking, there are also important differences in these constructs and their relationship to the stages of working memory during adolescence. PMID:24582821
NASA Astrophysics Data System (ADS)
Yamamoto, Masa-yuki; Kakinami, Yoshihiro; Kono, Hiroki
In Japan, the high altitude balloon for scientific observation has been continuously launched by JAXA. The balloon has a possibility to reach 50 km altitude without tight environmental condition for onboard equipments, operating with a cost lower than sounding rockets, however, development of the large-scale scientific observation balloons by university laboratories is still difficult. Being coupled with recent improvement of semiconductor sensors, laboratory-basis balloon experiments using small weather balloons has been becoming easily in these years. Owing to an advantage of wide land fields in continental regions, the launch of such small balloons has become to be carried out many times especially in continental countries (e.g. Near Space Ventures, Inc., 2013). Although the balloon is very small as its diameter of 6 feet, excluding its extra buoyancy and the weight of the balloon itself, it is expected that about 2 kg loading capacity is remained for payloads to send it up to about 35 km altitude. However, operation of such balloons in Japan is not in general because precise prediction of a landing area of the payload is difficult, thus high-risk situation for balloon releases is remained. In this study, we aim to achieve practical engineering experiments of weather balloons in Japan to be used for scientific observation within university laboratory level as an educational context. Here we report an approach of developing many devices for a small tethered balloon currently in progress. We evaluated an accuracy of altitude measurement by using a laboratory developed altitude data logger system that consists of a GPS-module and a barometric altimeter. Diameter of the balloon was about 1.4 m. Being fulfilled with about 1440 L helium, it produced buoyancy of about 15.7 N. Taking into account of total weight including the mooring equipments, available payload mass becomes to be about 1100 g. Applying an advantage of a 3D printer of FDM (Fused Deposition Modeling) method with a 3DCAD design software, we designed and manufactured a camera-platform type antenna rotator that automatically track the balloon direction based on the received GPS data as a balloon operation system on ground with automatic controlling software for the tracking system. In order to develop a future telemetry system onboard a small weather balloon, we have performed an onboard data logger system. In this presentation, system configuration of the automatic tracking system will be introduced more in detail. The telemetry system onboard the small balloon is currently under development. We have a plan to send the measured GPS coordinates, temperature, pressure, and humidity data detected by the onboard sensors to ground. A monitoring camera, a 3-axes accelerometer, geomagnetic azimuth measurement, and power monitoring were added to the developed data logger system. The acquired data will be stored in an SD card aboard as well as transmitted to the ground. Using a vacuum chamber with a pressure sensors and a constant-temperature reservoir in laboratory, environmental tests were operated. In this presentation, introducing the data obtained through the development of a prototype balloon system, our recent results and problems will be discussed.
[Drug-coated Balloon Angioplasty in Femoropopliteal Arteries - Is There a Class Effect?
Teichgräber, Ulf Karl-Martin; Klumb, Christof
2017-10-01
Aim Percutaneous transluminal angioplasty (PTA) is a well-accepted method to re-establish patency in stenotic and reoccluded vessels. One tool to improve results may be to use paclitaxel drug-coated balloon (DCB) catheters. This systematic review investigates whether there is a class effect among different DCBs. Methods The primary endpoint was "Freedom from Target Lesion Revascularisation" (FfTLR) after 12 months. A systematic literature search was performed in PubMed and risk of bias was assessed of the included trials. Efficacy of DCB vs. POBA (plain old balloon angioplasty) in binary outcomes was investigated with relative risks and number needed to treat (NNT). Results Ten trials including 1835 patients and investigating six different DCB were identified. A high risk of bias was found in these studies. There was a lower Late Lumen Loss at six months and a higher FfTLR and primary patency at one year after DCB-treatment. However, results varied greatly with NNTs ranging from three to thirty-three. Overall, there were no differences in ABI- and Rutherford-Outcome as well as incidence of adverse events. Conclusion Tested DCBs were able to improve PTA results at one year. There were large differences in efficacy between different DCB. A class effect cannot be confirmed yet. There is a risk of overestimating the effect of DCBs due to the high risk of bias in the included trials. Georg Thieme Verlag KG Stuttgart · New York.
Byrne, Jamie E M; Murray, Greg
2017-01-01
A range of evidence suggests that human reward functioning is partly driven by the endogenous circadian system, generating 24-hour rhythms in behavioural measures of reward activation. Reward functioning is multifaceted but literature to date is largely limited to measures of self-reported positive mood states. The aim of this study was to advance the field by testing for hypothesised diurnal variation in previously unexplored components of psychological reward: 'wanting', liking, and learning using subjective and behavioural measures. Risky decision making (automatic Balloon Analogue Risk Task), affective responsivity to positive images (International Affective Pictures System), uncued self-reported discrete emotions, and learning-contingent reward (Iowa Gambling Task) were measured at 10.00 hours, 14.00 hours, and 19.00 hours in a counterbalanced repeated measures design with 50 healthy male participants (aged 18-30). As hypothesised, risky decision making (unconscious 'wanting') and ratings of arousal towards positive images (conscious wanting) exhibited a diurnal waveform with indices highest at 14.00 hours. No diurnal rhythm was observed for liking (pleasure ratings to positive images, discrete uncued positive emotions) or in a learning-contingent reward task. Findings reaffirm that diurnal variation in human reward functioning is most pronounced in the motivational 'wanting' components of reward.
Abnormal placental invasion--a novel approach to treatment case report and review.
Ophir, Ella; Singer-Jordan, Jonathan; Odeh, Marwan; Hirch, Yael; Maksimovsky, Olga; Shaider, Oleg; Yvry, Simon; Solt, Ido; Bornstein, Jacob
2009-12-01
The incidence of abnormal placental invasion has increased 10-fold in the past 50 years, reflecting the increased number of cesarean sections performed. Management relies on accurate early diagnosis with appropriate perioperative multidisciplinary planning to anticipate and avoid massive obstetric hemorrhage at delivery. Women at risk should plan to deliver at an institution with appropriate expertise and resources for managing this condition. We report a case of placenta increta management comprising preoperative placement of a pelvic artery balloon catheter, prophylactic balloon occlusion after delivery of the fetus, and embolization-assisted resection of the invaded uterine wall. We review incidence, methods of prenatal diagnosis, risk factors, and management of abnormally invasive placenta.
Design of an everting balloon to deploy a microendoscope to the fallopian tubes
NASA Astrophysics Data System (ADS)
Keenan, Molly; Howard, Caitlin; Tate, Tyler; McGuiness, Ian; Sauer-Budge, Alexis; Black, John; Utzinger, Urs; Barton, Jennifer K.
2016-02-01
The 5-year survival rate for ovarian cancer is only 45% largely due to lack of effective screening methods. Current methods include palpation, transvaginal ultrasound, and the CA-125 blood test. Finding disease reliably and at an early stage increase survival to 92%. We have designed and built a 0.7 mm endoscope for the early detection of ovarian cancer. Inserted transvaginally through the working channel of a hysteroscope, the falloposcope creates a minimally invasive procedure for the screening of high risk women. To improve the ease-of-use and safety of falloposcope deployment, we are working to create an everting balloon. Currently, the falloposcope would require a skilled user to operate due to the challenging anatomy of the fallopian tubes - a small opening from the uterus (< 1 mm), tortuous path, and delicate lumenal features. A balloon delivery system would gently open the fallopian tube and guide the falloposcope down the center of lumen. We show balloon design and discuss integration with the falloposcope prototype. We test possible mechanical damage to the tissue due to scraping, puncture, or overstretching. Successful introduction of the everting balloon to simplify falloposcope delivery could expand screening beyond specialized centers to smaller clinical locations.
Mojkowska, Aleksandra; Gazdzinski, Stefan; Fraczek, Mariusz; Wyleżoł, Mariusz
2017-01-01
Some morbidly obese patients do not qualify for bariatric surgery due to general health contraindications. Intragastric balloon treatment might be a therapeutic option in the above-mentioned cases. It can prime super-obese patients with end-stage disease for bariatric surgery. As a neoadjuvant therapy before surgery, it leads to a downstage of the disease by preliminary weight reduction, to an improvement in general health and, in summary, to a reduction of the perioperative risk. It is generally considered to be a safe method. However, due to the wide range of possible complications and unusual symptoms after intragastric balloon treatment, an interdisciplinary, instead of only a surgical or endoscopic, treatment and follow-up might be recommended in these patients. We here describe a potential life-threatening complication in the form of gastric bleeding as a consequence of intragastric balloon treatment and simultaneous aspirin taking and Helicobacter pylori infection. There have been reports of some complications of intragastric balloon treatment. However, to the best of our knowledge there were no reports concerning life-threatening hemorrhage from gastric ulcer. © 2017 The Author(s) Published by S. Karger GmbH, Freiburg.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Çildağ, Mehmet Burak, E-mail: mbcildag@yahoo.com; Çildağ, Songül, E-mail: songulcildag@yahoo.com; Köseoğlu, Ömer Faruk Kutsi, E-mail: kutsikoseoglu@yahoo.com
ObjectiveThe aim of this study is to investigate the potential association of neutrophil–lymphocyte ratio (NLR) between primary patency of percutaneous transluminal angioplasty (PTA) in hemodialysis arteriovenous fistula stenosis and type (Conventional and Drug-Eluting) of balloons used in PTA.Material-MethodThis retrospective study consists of 78 patients with significant arteriovenous fistulas stenosis who were treated with PTA by using Drug-Eluting Balloon (DEB) (n = 29) or Conventional Balloon (CB) (n = 49). NLR was calculated from preinterventional blood samples. All patients were classified into two groups. Group A; primary patency <12 months (43/78), Group B; primary patency ≥12 months (35/78). Cox regression analysis and Kaplan–Meier method were used to determine respectivelymore » independent factors affecting the primary patency and to compare the primary patency for the two balloon types.ResultsNLR ratio and balloon type of the two groups were significantly different (p = 0.002, p = 0.010). The cut-off value of NLR was 3.18 for determination of primary patency, with sensitivity of 81.4 % and specificity of 51.4 %. Primary patency rates between PTA with DEB and CB displayed statistically significant differences (p < 0.05). The cut-off value was 3.28 for determination of 12-month primary patency with the conventional balloon group; sensitivity was 81.8 % and specificity was 81.3 %. There was no statistical relation between NLR levels and the drug-eluting balloon group in 12-month primary patency (p = 0.927).ConclusionIncreased level of NLR may be a risk factor in the development of early AVF restenosis after successful PTA. Preferring Drug-Eluting Balloon at an increased level of NLR can be beneficial to prolong patency.« less
Ten years single-centre experience with intra-aortic balloon pump.
Vandenplas, Guy; Bové, Thierry; Caes, Frank; Van Belleghem, Yves; François, Katrien; De Somer, Filip; Taeymans, Yves; Van Nooten, Guido
2011-12-01
The objective of this study was to investigate the patient characteristics and outcomes in 1406 patients undergoing intra-aortic balloon pump (IABP) counterpulsation. Between 1998 and 2008, 1406 consecutive patients were recorded in a prospective database. Based on the main clinical indication for IABP use, we defined 3 groups: group A, 630 cases of coronary ischaemia or infarction without serious left ventricular (LV) dysfunction; group B, 466 patients with left ventricular failure or cardiogenic shock; group C, 310 patients where IABP was used for miscellaneous procedures such as weaning from cardiopulmonary bypass or during high-risk angioplasty or surgery. Global mortality was 28% (n = 390), with a significant difference between group A (15%, n = 95) and group B (41%, n = 191) (P < 0.001). Mortality in group C was 34% (n = 104). Most insertions were done in the catheterization laboratory (n = 943) with subsequent mortality of 23% whereas 199 balloons were inserted in the operation room with 34% mortality. 170 balloons inserted in the intensive care unit resulted in 46% mortality (P < 0.001). Major IABP-induced complications were 6.8% with no statistical differences between the three groups. Advanced age, left ventricular failure and low BMI were identified as prognostic risk factors for early mortality. IABP deployed at an early clinical stage yields the best results, especially for acute coronary patients with preserved LV function whereas LV failure and late insertion result in worse outcome.
Bybee, Kevin A; Kara, Tomas; Prasad, Abhiram; Lerman, Amir; Barsness, Greg W; Wright, R Scott; Rihal, Charanjit S
2004-12-07
The transient left ventricular apical ballooning syndrome, also known as takotsubo cardiomyopathy, is characterized by transient wall-motion abnormalities involving the left ventricular apex and mid-ventricle in the absence of obstructive epicardial coronary disease. In this paper, we review case series that report on patients with the transient left ventricular apical ballooning syndrome to better characterize patients presenting with the syndrome. We identified 7 case series that reported on at least 5 consecutive patients with the transient left ventricular apical ballooning syndrome. The syndrome more often affects postmenopausal women (82% to 100%) (mean age, 62 to 75 years). Patients commonly present with ST-segment elevation in the precordial leads, chest pain, relatively minor elevation of cardiac enzyme and biomarker levels, and transient apical systolic left ventricular dysfunction despite the absence of obstructive epicardial coronary disease. An episode of emotional or physiologic stress frequently precedes presentation with the syndrome. The in-hospital mortality rate seems to be low, as does the risk for recurrence.
A Low Cost Weather Balloon Borne Solar Cell Calibration Payload
NASA Technical Reports Server (NTRS)
Snyder, David B.; Wolford, David S.
2012-01-01
Calibration of standard sets of solar cell sub-cells is an important step to laboratory verification of on-orbit performance of new solar cell technologies. This paper, looks at the potential capabilities of a lightweight weather balloon payload for solar cell calibration. A 1500 gr latex weather balloon can lift a 2.7 kg payload to over 100,000 ft altitude, above 99% of the atmosphere. Data taken between atmospheric pressures of about 30 to 15 mbar may be extrapolated via the Langley Plot method to 0 mbar, i.e. AMO. This extrapolation, in principle, can have better than 0.1 % error. The launch costs of such a payload arc significantly less than the much larger, higher altitude balloons, or the manned flight facility. The low cost enables a risk tolerant approach to payload development. Demonstration of 1% standard deviation flight-to-flight variation is the goal of this project. This paper describes the initial concept of solar cell calibration payload, and reports initial test flight results. .
Agesen, R M; Kristensen, P L; Beck-Nielsen, H; Nørgaard, K; Perrild, H; Christiansen, J S; Jensen, T; Hougaard, P; Parving, H H; Thorsteinsson, B; Tarnow, L; Pedersen-Bjergaard, U
2016-09-01
Insulin analogues reduce the risk of hypoglycaemia compared with human insulin in patients with type 1 diabetes (T1D) and minor hypoglycaemia problems. The HypoAna trial showed that, in patients with recurrent severe hypoglycaemia, treatment based on insulin analogues reduces the risk of severe hypoglycaemia. The present study aims to assess whether this also applies to non-severe hypoglycaemia events during the day and at night. This 2-year investigator-initiated multicentre, prospective, randomized, open, blinded endpoint (PROBE) trial involved patients with T1D and at least two episodes of severe hypoglycaemia during the previous year. Using a balanced crossover design, patients were randomized to basal-bolus therapy based on analogue (detemir/aspart) or human (NPH/regular) insulins. A total of 114 participants were included. Endpoints were the number of severe hypoglycaemic events and non-severe events, including documented symptomatic and asymptomatic episodes occurring during the day and at night (ClinicalTrials.gov number: NCT00346996). Analogue-based treatment resulted in a 6% (2-10%; P=0.0025) overall relative risk reduction of non-severe hypoglycaemia. This was due to a 39% (32-46%; P<0.0001) reduction of non-severe nocturnal hypoglycaemia, seen for both symptomatic (48% [36-57%]; P<0.0001) and asymptomatic (28% [14-39%]; P=0.0004) nocturnal hypoglycaemia episodes. No clinically significant differences in hypoglycaemia occurrence were observed between the insulin regimens during the day. The time needed to treat one patient with insulin analogues to avoid one episode (TNT1) of non-severe nocturnal hypoglycaemia was approximately 3 months. In T1D patients prone to severe hypoglycaemia, treatment with analogue insulin reduced the risk of non-severe nocturnal hypoglycaemia compared with human insulin. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
A new approach to fertility-preserving surgery in patients with placenta accreta.
Barinov, Sergey; Tirskaya, Yuliya; Medyannikova, Irina; Shamina, Inna; Shavkun, Inna
2017-12-05
The aim of this study was to evaluate the efficacy of a novel combined surgical approach utilising: (1) two autonomous balloon Zhukovsky catheters (vaginal and uterine), (2) bilateral ligation of the descending uterine artery branches, (3) external supraplacental pleated sutures, and (4) either excision of a small area of placenta accreta or full metroplasty, for the management of uterine bleeding associated with placenta accreta of various severity. The study included medical records of 92 pregnant women with placenta accreta undergoing a caesarean section. To evaluate the efficacy of the proposed management strategy, study participants were divided into three groups. In Group 1 (controls, n = 47), we utilised the combination of bilateral ligation, Barinov external supraplacental pleated sutures, and either excision of the tightly attached portion of placenta accreta or metroplasty. In Group 2 (n = 20), the abovementioned surgical techniques were additionally combined with balloon tamponade using an intrauterine Zhukovsky catheter. In Group 3 (n = 25), we additionally used an intravaginal Zhukovsky balloon catheter to enhance the efficacy of intrauterine tamponade. The use of an intrauterine balloon catheter combined with metroplasty was associated with a reduction in blood loss volume and blood transfusion rate by 1.9-fold, while the use of intravaginal balloon catheter reduced blood transfusion rate by 2.4-fold. The uterine balloon catheter reduced the risk of hysterectomy by 11-fold. Simultaneous use of two Zhukovsky balloon catheters (intravaginal and intrauterine) during caesarean section facilitates fertility-preserving surgery in patients with placenta accreta even in the cases of low-segment bleeding, thereby representing a promising approach to management of these patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanaka, Ryoichi; Higashi, Masahiro; Naito, Hiroaki
2007-07-15
Purpose. We examined the efficacy of conventional balloon angioplasty and cutting balloon angioplasty (CBA) for the treatment of non-arteriosclerotic renal artery stenosis (RAS). Materials and Methods. From 1993 to 2005, 20 patients underwent 27 percutaneous transluminal renalangioplasty (PTRA) for non-arteriosclerotic RAS (men: 8, women: 12, 25.5 +/- 2 years old; 16 fibromuscular dysplasia (FMD), 4 Takayasu disease). We evaluated the efficacy of CBA by comparing the rate of initial technical success and surgical conversion. Results. Before the clinical authorization of CBA, three of twelve patients (25 %) underwent surgical bypass due to the failure of PTRA due to the hardnessmore » of the lesion. After the approval of cutting balloon, we performed CBA in four cases (2 FMD,2 Takayasu disease) to dilate hard lesions, within which a properly sized balloon could not dilate due to their hardness, or to reduce the risk of local dissection. Initial successes were obtained in all patients (8/8, 100%) and none of the patients underwent surgical conversion. Despite of the good initial result, restenosis was observed in three cases within 6 month (3/4, 75 %). Additional interventions were performed in all patients, then, the severity of the restenotic lesion was found not to be exceeded comparing with the initial lesion. Conclusion. The cutting balloon angioplasty may be safe and useful procedure for hard lesions of RAS caused by non-arteriosclerotic disease? especially fibromuscular dysplasia. The cutting balloon may provide the initial success, but the effect on long-term patency is still controversial.« less
de Moura, Eduardo G H; Orso, Ivan R B; Aurélio, Eduardo F; de Moura, Eduardo T H; de Moura, Diogo T H; Santo, Marco A
2016-01-01
Roux-en-Y gastric bypass is a commonly used technique of bariatric surgery. One of the most important complications is gastrojejunal anastomotic stricture. Endoscopic balloon dilation appears to be well tolerated and effective, but well-designed randomized, controlled trials have not yet been conducted. Identify factors associated with complications or failure of endoscopic balloon dilation of anastomotic stricture secondary to Roux-en-Y gastric bypass surgery. Gastrointestinal endoscopy service, university hospital, Brazil. The records of 64 patients with anastomotic stricture submitted to endoscopic dilation with hydrostatic balloon dilation were reviewed. Information was collected on gastric pouch length, anastomosis diameter before dilation, number of dilation sessions, balloon diameter at each session, anastomosis diameter after the last dilation session, presence of postsurgical complications, endoscopic complications, and outcome of dilation. Comparisons were made among postsurgical and endoscopic complications; number of dilations, balloon diameter; anastomosis diameter before dilation; and dilation outcome. Success of dilation treatment was 95%. Perforation was positively and significantly associated with the number of dilation sessions (P = .03). Highly significant associations were found between ischemic segment and perforation (P<.001) and between ischemic segment and bleeding (P = .047). Ischemic segment (P = .02) and fistula (P = .032) were also associated with dilation failure. Ischemic segment and fistula were found to be important risk factors for balloon dilation failure. The greater the number of dilation sessions, the greater the number of endoscopic complications. Copyright © 2016 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Vascular complications following intra-aortic balloon pump implantation: an updated review
de Jong, Monique M; Lorusso, Roberto; Al Awami, Fatima; Matteuci, Francesco; Parise, Orlando; Lozekoot, Pieter; Bonacchi, Massimo; Maessen, Jos G; Johnson, Daniel M; Gelsomino, Sandro
2017-01-01
Background: The use of the intra-aortic balloon pump (IABP) as a support device remains controversial due to the fact that a number of studies have shown no benefit in end mortality whilst using this device. One of the reasons for this could be the increase in vascular complications when using the pump. Therefore, the aim of the present review was to assess the current literature available with regards to IABP vascular complications during the clinical situation. Methods: A literature search was performed, searching for IABP complications in adult human studies between 1990 and 2016. Results: A total of 20 reports were identified as fitting the criteria of this study. The majority of vascular complications were limb ischemia, bleeding or mesenteric ischemia. The overall incidence of vascular complications ranged from 0.94% to 31.1%. Diabetes, peripheral vascular disease and hypertension, as well as smoking were all identified as risk factors for complications following IABP. Furthermore, studies supported the use of sheathless balloon insertion to reduce the risk of complications. Conclusion: Major vascular complications, including limb and mesenteric ischemia as well as bleeding and hemorrhage, have been associated with IABP. However, the incidence of these complications was generally low. Further studies are still required to truly understand the risk/benefit associated with the use of IABP. PMID:28816093
Risk-Taking Propensity as a Predictor of Induction onto Naltrexone Treatment for Opioid Dependence
Aklin, Will M.; Severtson, S. Geoffrey; Umbricht, Annie; Fingerhood, Michael; Bigelow, George E.; Lejuez, C. W.; Silverman, Kenneth
2014-01-01
Objective Heroin addiction is a chronic relapsing disorder that has devastating social, medical, and economic consequences. Naltrexone is an antagonist that blocks opioid effects and could be an effective medication for the treatment of opioid dependence. However, its clinical utility has been limited partly because of poor adherence and acceptability. Given the importance of compliance to naltrexone treatment for opioid dependence, the goal of the current study was to examine predictors involved in successful induction onto naltrexone treatment. Method Parametric and nonparametric statistical tests were performed on data from a sample of 64 individuals entering treatment who met DSM-IV criteria for opioid dependence. The relationship between naltrexone induction (i.e., inducted- vs. not-inducted onto naltrexone) and risk-taking propensity, as indexed by riskiness on the Balloon Analogue Risk Task (BART) was examined. Participants were recruited from local detoxification programs, inpatient drug treatment, and other Baltimore programs that provided services to opioid dependent adults (e.g., Baltimore Needle Exchange Program) during the period from August 2007 to September 2008. Results Positive association between risk-taking propensity and odds of naltrexone induction. Specifically, each five point increase in the total BART score was associated with a 25% decrease in odds of naltrexone induction (OR=0.76, 95% CI: 0.58–0.99, p = .041). This association remained statistically significant even after adjusting for potential confounds, including injection drug use and cocaine positive urine results (p = .05). After adjusting for the covariates, each five point increase in BART score was associated with 28% decrease in the odds of achieving the maintenance dose (AOR=0.73, 95% CI: 0.54–0.99, p = .046). Conclusions Risk taking propensity was predictive of induction onto naltrexone treatment, above and beyond injection drug use and cocaine-positive urine samples. PMID:22967782
Herard, A; Colin, J; Youinou, Y; Drancourt, E; Brandt, B
1998-08-01
We report the case of a patient with heterozygous sickle cell trait presenting with massive gross hematuria. Ureteroscopy revealed bleeding from the tip of papilla of the inferior calica and allowed us to tamponade the bleeding with a balloon ureteral dilator set (Cook(R) Urology). We show the value of the endourological approach in the conservative management of these patients at high risk of recurrent hematuria.
Pulmonic stenosis in dogs: survival and risk factors in a retrospective cohort of patients.
Locatelli, C; Spalla, I; Domenech, O; Sala, E; Brambilla, P G; Bussadori, C
2013-09-01
To assess survival and risk factors in dogs with pulmonic stenosis. A retrospective review of medical case records of all cases of pulmonic stenosis >50 mmHg, undergoing pulmonary balloon valvuloplasty or not. Survival curves and multivariate analysis were calculated in the overall population and in subgroups. One hundred and seventy-two cases were included. Factors negatively affecting survival were clinical signs [hazard ratio (HR) 3 · 44, P < 0 · 001], younger age at diagnosis (HR 3 · 96, P = 0 · 001) and valve morphology type B (HR 3 · 33, P = 0 · 001) in the overall population. In those that had pulmonary balloon valvuloplasty group only clinical signs was significant (HR 3 · 44, P < 0 · 001). In cases that did not undergo pulmonary balloon valvuloplasty group Doppler gradient (HR 1 · 02, P < 0 · 001), clinical signs (HR 5 · 41, P = 0 · 002), valve morphology type B (HR 10 · 20, P = 0 · 001) and younger age at diagnosis (HR 12 · 82, P < 0 · 001) negatively affected survival. Dogs with severe pulmonic stenosis undergoing pulmonary balloon valvuloplasty (HR 0 · 47, P = 0 · 047) and asymptomatic dogs with moderate pulmonic stenosis (HR 0 · 10, P = 0 · 042) had a better outcome. Younger age at diagnosis was correlated with poorer outcome in right-sided congestive heart failure dogs (HR 14 · 02, P = 0 · 01). Clinical signs, valve morphology type B and age at diagnosis are risk factors in pulmonic stenosis patients. Pulmonary balloon valvuloplasty is a reasonable treatment choice in dogs with severe pulmonic stenosis. © 2013 British Small Animal Veterinary Association.
Current Status of a NASA High-Altitude Balloon-Based Observatory for Planetary Science
NASA Technical Reports Server (NTRS)
Varga, Denise M.; Dischner, Zach
2015-01-01
Recent studies have shown that progress can be made on over 20% of the key questions called out in the current Planetary Science Decadal Survey by a high-altitude balloon-borne observatory. Therefore, NASA has been assessing concepts for a gondola-based observatory that would achieve the greatest possible science return in a low-risk and cost-effective manner. This paper addresses results from the 2014 Balloon Observation Platform for Planetary Science (BOPPS) mission, namely successes in the design and performance of the Fine Pointing System. The paper also addresses technical challenges facing the new Gondola for High Altitude Planetary Science (GHAPS) reusable platform, including thermal control for the Optical Telescope Assembly, power generation and management, and weight-saving considerations that the team will be assessing in 2015 and beyond.
MacPherson, Laura; Calvin, Nicholas T.; Richards, Jessica M.; Guller, Leila; Mayes, Linda C.; Crowley, Michael J.; Daughters, Stacey B.; Lejuez, C.W.
2011-01-01
Background A long line of theoretical and empirical evidence implicates negative reinforcement as a process underlying the etiology and maintenance of risky alcohol use behaviors from adolescence through emerging adulthood. However, the bulk of this literature has relied on self-report measures and there is a notable absence of behavioral modes of assessments of negative reinforcement-based alcohol-related risk-taking. To address this clear gap in the literature, the current study presents the first published data on the reliability and validity of the Maryland Resource for the Behavioral Utilization of the Reinforcement of Negative Stimuli (MRBURNS), which is a modified version of the positive reinforcement-based Balloon Analogue Risk Task (BART). Methods Participants included a convenience sample of 116 college freshmen ever regular drinkers (aged 18–19) who completed both behavioral tasks; self-report measures of negative reinforcement/avoidance constructs and of positive reinforcement/appetitive constructs to examine convergent validity and discriminant validity, respectively; and self-report measures of alcohol use, problems, and motives to examine criterion validity. Results The MRBURNS evidenced sound experimental properties and reliability across task trials. In support of convergent validity, risk taking on the MRBURNS correlated significantly with negative urgency, difficulties in emotion regulation and depressive and anxiety-related symptoms. In support of discriminant validity, performance on the MRBURNS was unrelated to risk taking on the BART, sensation seeking, and trait impulsivity. Finally, pertaining to criterion validity, risk taking on the MRBURNS was related to alcohol-related problems but not heavy episodic alcohol use. Notably, risk taking on the MRBURNS was associated with negative reinforcement-based but not with positive reinforcement-based drinking motives. Conclusions Data from this initial investigation suggest the utility of the MRBURNS as a behavioral measure of negative-reinforcement based risk-taking that can provide a useful compliment to existing self-report measures to improve our understanding of the relationship between avoidant reinforcement processes and risky alcohol use. PMID:22309846
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cil, Barbaros E., E-mail: barbaroscil@hotmail.com, E-mail: barbaros@hacettepe.edu.tr; Erdogan, Cueneyt; Akmangit, Ilkay
Pulmonary arteriovenous malformation (PAVM) is a rare vascular malformation of the lung which may occur as an isolated entity or in association with hereditary hemorrhagic telangiectasia (HHT). Because of considerable risk of serious complications such as cerebral embolism, brain abscess and pulmonary hemorrhage, definitive treatment should be considered in most patients. Embolization with coils or detachable balloons is currently the preferred treatment. Paradoxical embolization of coils and balloons may happen, especially in patients with PAVMs with large feeding arteries. In this report we present our initial experience with the use of the TriSpan coil to lower the risk of coilmore » migration during the transcatheter occlusion of PAVMs.« less
Lousuebsakul-Matthews, Vichuda; Thorpe, Donna L; Knutsen, Raymond; Beeson, W Larry; Fraser, Gary E; Knutsen, Synnove F
2014-10-01
In contrast to non-vegetarians, vegetarians consume more legumes and meat analogues as sources of protein to substitute for meat intake. The present study aimed to assess the association between foods with high protein content (legumes, meat, meat analogues) by dietary pattern (vegetarians, non-vegetarians) and hip fracture incidence, adjusted for selected lifestyle factors. A prospective cohort of Adventist Health Study-2 (AHS-2) enrollees who completed a comprehensive lifestyle and dietary questionnaire between 2002 and 2007. Every two years after enrolment, a short questionnaire on hospitalizations and selected disease outcomes including hip fractures was sent to these members. Respondents (n 33,208) to a baseline and a follow-up questionnaire. In a multivariable model, legumes intake of once daily or more reduced the risk of hip fracture by 64% (hazard ratio = 0·36, 95% CI 0·21, 0·61) compared with those with legumes intake of less than once weekly. Similarly, meat intake of four or more times weekly was associated with a 40% reduced risk of hip fracture (hazard ratio = 0·60, 95% CI 0·41, 0·87) compared with those whose meat intake was less than once weekly. Furthermore, consumption of meat analogues once daily or more was associated with a 49 % reduced risk of hip fracture (hazard ratio = 0·51, 95% CI 0·27, 0·98) compared with an intake of less than once weekly. Hip fracture incidence was inversely associated with legumes intake and, to a lesser extent, meat intake, after accounting for other food groups and important covariates. Similarly, a high intake of meat analogues was associated with a significantly reduced risk of hip fracture.
Gastro-oesophageal reflux in mechanically ventilated patients: effects of an oesophageal balloon.
Orozco-Levi, M; Félez, M; Martínez-Miralles, E; Solsona, J F; Blanco, M L; Broquetas, J M; Torres, A
2003-08-01
Gastro-oesophageal reflux (GOR) and bronchoaspiration of gastric content are risk factors linked with ventilator-associated pneumonia. This study was aimed at evaluating the effect of a nasogastric tube (NGT) incorporating a low-pressure oesophageal balloon on GOR and bronchoaspiration in patients receiving mechanical ventilation. Fourteen patients were studied in a semi-recumbent position for 2 consecutive days. Inflation or deflation of the oesophageal balloon was randomised. Samples of blood, gastric content, and oropharyngeal and bronchial secretions were taken every 2 h over a period of 8 h. A radioactively labelled nutritional solution was continuously administered through the NGT. The magnitude of both the GOR and bronchoaspiration was measured by radioactivity counting of oropharyngeal and bronchial secretion samples, respectively. Inflation of the oesophageal balloon resulted in a significant decrease of both GOR and bronchoaspiration of gastric content. This protective effect was statistically significant from 4 h following inflation throughout the duration of the study. This study demonstrates that an inflated oesophageal balloon delays and decreases gastro-oesophageal and bronchial aspiration of gastric content in patients carrying a nasogastric tube and receiving enteral nutrition during mechanical ventilation. Although the method was found to be safe when applied for 8 h, longer times should be considered with caution.
Goldsweig, Andrew M; Faheem, Osman; Cleman, Michael W; Forrest, John K
2015-06-01
We sought to perform transcatheter aortic valve replacement (TAVR) via the transfemoral approach in patients with peripheral arterial disease (PAD), small caliber ileofemoral vessels and vascular tortuosity. For patients with increased surgical risk, TAVR is associated with a higher 1-year survival rate than surgical aortic valve replacement (SAVR). Transfemoral vascular access for TAVR results in superior outcomes versus procedures performed via other routes in terms of mortality, morbidity and healthcare economics. In many patients, the ability to safely perform the procedure via the transfemoral approach is limited by narrow, diseased and tortuous ileofemoral vasculature. We employed the SoloPath Balloon Expandable TransFemoral Access System (Terumo Med. Corp., Tokyo, Japan) to perform transfemoral TAVR in five patients with PAD, small caliber ileofemoral vessels and vascular tortuosity. We report our experience using this balloon-expandable sheath during 5 cases of transfemoral TAVR in patients with inhospitable ileofemoral vasculature of mean diameter ⩽ 5.8 mm. The unexpanded sheath's malleable structure and hydrophilic coating permitted deployment despite severe stenoses and tortuosity. Subsequent inflation to 18 Fr facilitated successful TAVR. Postprocedural angiography demonstrated no significant vascular access complications. In one case, the entire procedure was performed percutaneously, without common femoral artery surgical cutdown. The SoloPath sheath system permits transfemoral TAVR in patients with PAD small caliber ileofemoral vessels and vascular tortuosity. The transfemoral balloon-expandable sheath allowed these patients to avoid the increased morbidity and mortality risks associated with direct aortic or transapical access. © The Author(s), 2015.
Meybohm, Patrick; Herrmann, Eva; Nierhoff, Julia; Zacharowski, Kai
2013-01-01
To compare the effect of aprotinin with the effect of lysine analogues (tranexamic acid and ε-aminocaproic acid) on early mortality in three subgroups of patients: low, intermediate and high risk of cardiac surgery. We performed a meta-analysis of randomised controlled trials and observational with the following data sources: Medline, Cochrane Library, and reference lists of identified articles. The primary outcome measure was early (in-hospital/30-day) mortality. The secondary outcome measures were any transfusion of packed red blood cells within 24 hours after surgery, any re-operation for bleeding or massive bleeding, and acute renal dysfunction or failure within the selected cited publications, respectively. Out of 328 search results, 31 studies (15 trials and 16 observational studies) included 33,501 patients. Early mortality was significantly increased after aprotinin vs. lysine analogues with a pooled risk ratio (95% CI) of 1.58 (1.13-2.21), p<0.001 in the low (n = 14,297) and in the intermediate risk subgroup (1.42 (1.09-1.84), p<0.001; n = 14,427), respectively. Contrarily, in the subgroup of high risk patients (n = 4,777), the risk for mortality did not differ significantly between aprotinin and lysine analogues (1.03 (0.67-1.58), p = 0.90). Aprotinin may be associated with an increased risk of mortality in low and intermediate risk cardiac surgery, but presumably may has no effect on early mortality in a subgroup of high risk cardiac surgery compared to lysine analogues. Thus, decisions to re-license aprotinin in lower risk patients should critically be debated. In contrast, aprotinin might probably be beneficial in high risk cardiac surgery as it reduces risk of transfusion and bleeding complications.
Meybohm, Patrick; Herrmann, Eva; Nierhoff, Julia; Zacharowski, Kai
2013-01-01
Background To compare the effect of aprotinin with the effect of lysine analogues (tranexamic acid and ε-aminocaproic acid) on early mortality in three subgroups of patients: low, intermediate and high risk of cardiac surgery. Methods and Findings We performed a meta-analysis of randomised controlled trials and observational with the following data sources: Medline, Cochrane Library, and reference lists of identified articles. The primary outcome measure was early (in-hospital/30-day) mortality. The secondary outcome measures were any transfusion of packed red blood cells within 24 hours after surgery, any re-operation for bleeding or massive bleeding, and acute renal dysfunction or failure within the selected cited publications, respectively. Out of 328 search results, 31 studies (15 trials and 16 observational studies) included 33,501 patients. Early mortality was significantly increased after aprotinin vs. lysine analogues with a pooled risk ratio (95% CI) of 1.58 (1.13–2.21), p<0.001 in the low (n = 14,297) and in the intermediate risk subgroup (1.42 (1.09–1.84), p<0.001; n = 14,427), respectively. Contrarily, in the subgroup of high risk patients (n = 4,777), the risk for mortality did not differ significantly between aprotinin and lysine analogues (1.03 (0.67–1.58), p = 0.90). Conclusion Aprotinin may be associated with an increased risk of mortality in low and intermediate risk cardiac surgery, but presumably may has no effect on early mortality in a subgroup of high risk cardiac surgery compared to lysine analogues. Thus, decisions to re-license aprotinin in lower risk patients should critically be debated. In contrast, aprotinin might probably be beneficial in high risk cardiac surgery as it reduces risk of transfusion and bleeding complications. PMID:23483965
Zhang, Ning; Lou, Wei-hua; Zhang, Xue-bin; Fu, Jia-ning; Chen, Yun-yan; Zhuang, Zhi-guo; Lin, Jian-hua
2017-01-01
The increasing incidence of morbidly adherent placenta (MAP) is placing women at a higher risk of life-threatening massive hemorrhage. The involvement of interventional radiology to manage this complex condition by performing prophylactic iliac artery balloon occlusion has been reported recently. However, the effectiveness and safety of this technique have not been fully determined. Here we report the case of a 25-year-old woman with placenta increta with preemptive bilateral internal iliac artery balloons who had external iliac artery thrombosis detected by computed tomography angiography (CTA) 72 h post cesarean section. A digital subtraction angiogram (DSA) and intra-arterial thrombolysis were instantly performed followed by supplementary conservative treatments, leading to a desirable resolution of thrombus without sequela. This is the first report of vascular complications with successful interventional thrombolysis in this setting. Our experience suggests that prophylactic iliac artery balloon occlusion should be used cautiously in cases of MAP and consideration given to minimizing vascular complications given the hypercoagulable state of pregnancy. PMID:28271663
Further aspects on cellular and cordless telephones and brain tumours.
Hardell, Lennart; Mild, Kjell Hansson; Carlberg, Michael
2003-02-01
We included in a case-control study on brain tumours and mobile and cordless telephones 1,617 patients aged 20-80 years of both sexes diagnosed during January 1, 1997 to June 30, 2000. They were alive at the study time and had histopathology verified brain tumour. One matched control to each case was selected from the Swedish Population Register. The study area was the Uppsala-Orebro, Stockholm, Linköping and Göteborg medical regions of Sweden. Exposure was assessed by a questionnaire that was answered by 1,429 (88%) cases and 1,470 (91%) controls. In total use of analogue cellular telephones gave an increased risk with odds ratio (OR)=1.3, 95% confidence interval (CI)=1.04-1.6, whereas digital and cordless phones did not overall increase the risk significantly. Ipsilateral use of analogue phones gave OR=1.7, 95% CI=1.2-2.3, digital phones OR=1.3, 95% CI=1.02-1.8 and cordless phones OR=1.2, 95% CI=0.9-1.6. The risk for ipsilateral use was significantly increased for astrocytoma for all studied phone types, analogue phones OR=1.8,95% CI=1.1-3.2, digital phones OR=1.8, 95% CI=1.1-2.8, cordless phones OR=1.8, 95% CI=1.1-2.9. Use of a telephone on the opposite side of the brain was not associated with a significantly increased risk for brain tumours. Regarding anatomical area of the tumour and exposure to microwaves, the risk was increased for tumours located in the temporal area on the same side of the brain that was used during phone calls, significantly so for analogue cellular telephones OR=2.3, 95% CI=1.2-4.1. For acoustic neurinoma OR=4.4, 95% CI=2.1-9.2 was calculated among analogue cellular telephone users. When duration of use was analysed as a continuous variable in the total material, the risk increased per year for analogue phones with OR=1.04, 95% CI=1.01-1.08. For astrocytoma and ipsilateral use the trend was for analogue phones OR=1.10, 95% CI=1.02-1.19, digital phones OR=1.11, 95% CI=1.01-1.22, and cordless phones OR=1.09, 95% CI=1.01-1.19. There was a tendency of a shorter tumour induction period for ipsilateral exposure to microwaves than for contralateral, which may indicate a tumour promotor effect.
Shah, Mamta; Lee, Grace; Lefebvre, Daniel R.; Kronberg, Benjamin; Loomis, Stephanie; Brauner, Stacey C.; Turalba, Angela; Rhee, Douglas J.; Freitag, Suzanne K.; Pasquale, Louis R.
2013-01-01
We studied the relation between prostaglandin analogue use and ocular adnexal features. We used a prospective, cross-sectional study involving 157 current, 15 past, and 171 never users of prostaglandin analogues. Patients 50 years of age or older and without conditions affecting ocular adnexal anatomy underwent glaucoma medication use history, external digital photography and systematic external adnexal exam. Two masked readers assessed the digital photos for upper lid dermatochalasis and lower lid steatoblepharon using a validated grading scheme. Another masked clinical examiner also assessed upper lid ptosis, levator muscle function, and inferior scleral show. We performed ordinal logistic regression analysis accounting for multiple covariates to assess the relation between prostaglandin analogue use and adnexal features. Multivariable analyses indicated there was a 230-fold increased risk of incremental involution of dermatochalasis (odds ratio (OR) = 2.30; 95% confidence interval (CI) 1.43–3.69; p = 5.44E-04) and a 249-fold increased risk of incremental loss of lower lid steatoblepharon (OR = 2.49; 95% CI, 1.54–4.03; p = 1.98E-04) associated with current prostaglandin analogue use (bimatoprost 0.03%, travoprost 0.005%, or latanoprost 0.004%) versus prostaglandin analogue never or past users. Upper lid ptosis (OR = 4.04; 95% CI, 2.43–6.72; p = 7.37E-08), levator dysfunction (OR = 7.51; 95% CI, 3.39–16.65; p = 6.74E-07) and lower lid retraction (OR = 2.60; 95% CI, 1.58–4.28; p = 1.72E-04) were highly associated with current prostaglandin analogue use versus prostaglandin analogue never or past users. The associations between prostaglandin analogue use and deepening of the upper lid sulci and between prostaglandin analogue use and loss of inferior periorbital fat are confirmed in this multivariable analysis. The associations between prostaglandin analogue use and levator muscle dysfunction and between prostaglandin analogue use and upper lid ptosis represent significant side effects that could impact visual function in glaucoma patients. PMID:23650502
GnRH Analogues in the Prevention of Ovarian Hyperstimulation Syndrome
Alama, Pilar; Bellver, Jose; Vidal, Carmen; Giles, Juan
2013-01-01
The GnRH analogue (agonist and antagonist GnRH) changed ovarian stimulation. On the one hand, it improved chances of pregnancy to obtain more oocytes and better embryos. This leads to an ovarian hyper-response, which can be complicated by the ovarian hyperstimulation syndrome (OHSS). On the other hand, the GnRH analogue can prevent the incidence of OHSS: GnRH antagonist protocols, GnRH agonist for triggering final oocyte maturation, either together or separately, coasting, and the GnRH analogue may prove useful for avoiding OHSS in high-risk patients. We review these topics in this article. PMID:23825982
Giacoppo, Daniele; Gargiulo, Giuseppe; Aruta, Patrizia; Capranzano, Piera; Tamburino, Corrado
2015-01-01
Study question What is the most safe and effective interventional treatment for coronary in-stent restenosis? Methods In a hierarchical Bayesian network meta-analysis, PubMed, Embase, Scopus, Cochrane Library, Web of Science, ScienceDirect, and major scientific websites were screened up to 10 August 2015. Randomised controlled trials of patients with any type of coronary in-stent restenosis (either of bare metal stents or drug eluting stents; and either first or recurrent instances) were included. Trials including multiple treatments at the same time in the same group or comparing variants of the same intervention were excluded. Primary endpoints were target lesion revascularisation and late lumen loss, both at six to 12 months. The main analysis was complemented by network subanalyses, standard pairwise comparisons, and subgroup and sensitivity analyses. Study answer and limitations Twenty four trials (4880 patients), including seven interventional treatments, were identified. Compared with plain balloons, bare metal stents, brachytherapy, rotational atherectomy, and cutting balloons, drug coated balloons and drug eluting stents were associated with a reduced risk of target lesion revascularisation and major adverse cardiac events, and with reduced late lumen loss. Treatment ranking indicated that drug eluting stents had the highest probability (61.4%) of being the most effective for target lesion vascularisation; drug coated balloons were similarly indicated as the most effective treatment for late lumen loss (probability 70.3%). The comparative efficacy of drug coated balloons and drug eluting stents was similar for target lesion revascularisation (summary odds ratio 1.10, 95% credible interval 0.59 to 2.01) and late lumen loss reduction (mean difference in minimum lumen diameter 0.04 mm, 95% credible interval −0.20 to 0.10). Risks of death, myocardial infarction, and stent thrombosis were comparable across all treatments, but these analyses were limited by a low number of events. Trials had heterogeneity regarding investigation periods, baseline characteristics, and endpoint reporting, with a lack of information at long term follow-up. Direct and indirect evidence was also inconsistent for the comparison between drug eluting stents and drug coated balloons. What this study adds Compared with other currently available interventional treatments for coronary in-stent restenosis, drug coated balloons and drug eluting stents are associated with superior clinical and angiographic outcomes, with a similar comparative efficacy. Funding, competing interests, data sharing This study received no external funding. The authors declare no competing interests. No additional data available. PMID:26537292
Debulking Atherectomy in the Peripheral Arteries: Is There a Role and What is the Evidence?
Katsanos, Konstantinos; Spiliopoulos, Stavros; Reppas, Lazaros; Karnabatidis, Dimitris
2017-07-01
Traditional percutaneous balloon angioplasty and stent placement is based on mechanical plaque disruption and displacement within the arterial wall. On the contrary, transcatheter atherectomy achieves atherosclerotic plaque clearance by means of directional plaque excision or rotational plaque removal or laser plaque ablation. Debulking atherectomy may allow for a more uniform angioplasty result at lower pressures with consequently less vessel barotrauma and improved luminal gain, thereby decreasing the risk of plaque recoil and dissection that may require permanent metal stenting. It has been also argued that atherectomy may disrupt the calcium barrier and optimize drug transfer and delivery in case of drug-coated balloon applications. The authors discuss the various types of atherectomy devices available in clinical practice to date and critically appraise their mode of action as well as relevant published data in each case. Overall, amassed randomized and observational evidence indicates that percutaneous atherectomy of the femoropopliteal and infrapopliteal arteries may achieve high technical success rates and seems to lessen the frequency of bailout stenting, however, at the expense of increased risk of peri-procedural distal embolization. Long-term clinical outcomes reported to date do not support the superiority of percutaneous atherectomy over traditional balloon angioplasty and stent placement in terms of vessel patency or limb salvage. The combination of debulking atherectomy and drug-coated balloons has shown promise in early studies, especially in the treatment of more complex lesions. Unanswered questions and future perspectives of this continuously evolving endovascular technology as part of a broader treatment algorithm are discussed.
Identifying DNA Methylation Biomarkers for Non-Endoscopic Detection of Barrett’s Esophagus
Moinova, Helen R.; LaFramboise, Thomas; Lutterbaugh, James D.; Chandar, Apoorva Krishna; Dumot, John; Faulx, Ashley; Brock, Wendy; De la Cruz Cabrera, Omar; Guda, Kishore; Barnholtz-Sloan, Jill S.; Iyer, Prasad G.; Canto, Marcia I.; Wang, Jean S.; Shaheen, Nicholas J.; Thota, Prashanti N.; Willis, Joseph E.; Chak, Amitabh; Markowitz, Sanford D.
2018-01-01
We report a biomarker-based non-endoscopic method for detecting Barrett’s esophagus (BE), based on detecting methylated DNAs retrieved via a swallowable balloon-based esophageal sampling device. BE is the precursor of, and a major recognized risk factor for, developing esophageal adenocarcinoma (EAC). Endoscopy, the current standard for BE detection, is not cost-effective for population screening. We performed genome-wide screening to ascertain regions targeted for recurrent aberrant cytosine methylation in BE, identifying high-frequency methylation within the CCNA1 locus. We tested CCNA1 DNA methylation as a BE biomarker in cytology brushings of the distal esophagus from 173 individuals with or without BE. CCNA1 DNA methylation demonstrated an area under the curve (AUC)=0.95 for discriminating BE-related metaplasia and neoplasia cases versus normal individuals, performing identically to methylation of VIM DNA, an established BE biomarker. When combined, the resulting two biomarker panel was 95% sensitive and 91% specific. These results were replicated in an independent validation cohort of 149 individuals, who were assayed using the same cutoff values for test positivity established in the training population. To progress toward non-endoscopic esophageal screening, we engineered a well-tolerated, swallowable, encapsulated balloon device able to selectively sample the distal esophagus within 5 minutes. In balloon samples from 86 individuals, tests of CCNA1 plus VIM DNA methylation detected BE metaplasia with 90.3% sensitivity and 91.7% specificity. Combining the balloon sampling device with molecular assays of CCNA1 plus VIM DNA methylation enables an efficient, well-tolerated, sensitive, and specific method of screening at-risk populations for BE. PMID:29343623
Zeng, Hong; Wang, Yan; Wang, Yang; Guo, Xiang-yang
2015-12-18
When placenta previa complicated with placenta percreta, the exposure of operative field is difficult and the routine methods are difficult to effectively control the bleeding, even causing life-threatening results. A 31-year-old woman, who had been diagnosed with a complete type of placenta previa and placenta percreta with bladder invasion at 34 weeks gestation. Her ultrasound results showed a complete type of placenta previa and there was a loss of the decidual interface between the placenta and the myometrium on the lower part of the uterus, suggestive of placenta increta. For further evaluation of the placenta, pelvis magnetic resonance imaging was performed, which revealed findings suspicious of a placenta percreta. She underwent elective cecarean section at 36 weeks of gestation. Firstly, two ureteral stents were placed into the bilateral ureter through the cystoscope. After the infrarenal abdominal aorta catheter was inserted via the femoral artery (9 F sheath ), subarachnoid anesthesia had been established. A healthy 2 510 g infant was delivered, with Apgar scores of 10 at 1 min and 10 at 5 min. Immediately after the baby was delivered, following which there was massive haemorrhage and general anaesthesia was induced. The balloon catheter was immediately inflated until the wave of dorsal artery disappeared. With the placenta retained within the uterus, a total hysterectomy was performed. The occluding time was 30 min. The intraoperative blood loss was 2 500 mL. The occluding balloon was deflated at the end of the operation. The patient had stable vital signs and normal laboratory findings during the recovery period and the hemoglobin was 116 g/L. She was discharged six days after delivery without intervention-related complications. This case illustrates that temporary occlusion of the infrarenal abdominal aorta using balloon might be a safe and effective treatment option for patients with placenta previa complicated with placenta percreta, who were at high risk for peripartum hemorrhage. Early removal of the endovascular catheter and close postoperative surveillance of the vascular system are required with this procedure to minimize the risk of vascular complications. However, further studies are needed to determine whether the potential benefits of temporary occlusion of the infrarenal abdominal aorta using balloon outweigh the potential risks.
Kuki, S; Taniguchi, K; Masai, T; Yoshida, K; Yamamoto, K; Matsuda, H
2001-01-01
The most important limitation in the use of an intra-aortic balloon pumping (IABP) is the risk of vascular complications. Recently, an IABP catheter with an 8.0 French shaft and low profile that may decrease the risk of vascular morbidity has been developed. We evaluated the in vitro balloon performance and the prevention of limb ischemia in clinical use. An 8.0 French IABP catheter was compared with a standard 9.5 French catheter. Inflation time (IT), deflation time (DT), and changes in volume (V) generated by the balloon were measured during the pumping cycle in an experimental model. The inflation velocity (V/IT) and deflation velocity (V/DT) were calculated as parameters of balloon performance. At 120 bpm the V/IT and V/DT were 0.34 ml/msec and 0.28 ml/msec with the 8.0 French, and 0.33 ml/msec and 0.24 ml/msec with the 9.5 French catheter. Twelve patients with coronary artery disease, ranging in age from 41 to 87 years (mean, 66 years), who underwent IABP support, were divided into group 1 (8.0 French, n = 4) and group 2 (9.5 French, n = 8). Ankle-arm pressure index (API), lactate extraction ratio (LER) in the limb with IABP insertion, and cardiac index (CI) were measured at 1, 12, and 24 hours postoperatively. There were no major vascular complications and no counterpulsation related morbidity. There was no significant difference between the two groups with regard to age, duration of IABP support, and incidence of peripheral vascular disease and diabetes. The percentage of women patients was significantly higher in group 1 (100% vs. 25%), whereas body surface area was significantly smaller (1.45 +/- 0.14 vs. 1.68 +/- 0.12 m2). The API in group 1 were slightly higher than those in group 2 throughout the observed period (not significant). The LER and Cl showed no significant differences between the two groups. These results suggest that the 8.0 French IABP catheter with a low profile has an acceptable in vitro performance, and its clinical application may be effective in preventing limb ischemia in a high-risk subset of patients such as women and smaller patients.
Drug eluting balloons for de novo coronary lesions – a systematic review and meta-analysis
2013-01-01
Background The role of drug-eluting balloons (DEB) is unclear. Increasing evidence has shown a benefit for the treatment of in-stent restenosis. Its effect on de novo coronary lesions is more controversial. Several smaller randomized trials found conflicting results. Methods This is a systematic review and meta-analysis of randomized controlled trials (RCT) evaluating the effect of local Paclitaxel delivery/drug eluting balloons (DEB) (+/− bare metal stent) compared to current standard therapy (stenting) to treat de novo coronary lesions. Data sources for RCT were identified through a literature search from 2005 through 28 December 2012. The main endpoints of interest were target lesion revascularization (TLR), major adverse cardiac events (MACE), binary in-segment restenosis, stent thrombosis (ST), myocardial infarction (MI), late lumen loss (LLL) and mortality. A random effects model was used to calculate the pooled relative risks (RR) with 95% confidence intervals. Results Eight studies (11 subgroups) and a total of 1,706 patients were included in this analysis. Follow-up duration ranged from 6 to 12 months. Overall, DEB showed similar results to the comparator treatment. The relative risk (RR) for MACE was 0.95 (0.64 to 1.39); P = 0.776, for mortality it was 0.79 (0.30 to 2.11), P = 0.644, for stent thrombosis it was 1.45 (0.42 to 5.01), P = 0.560, for MI it was 1.26 (0.49 to 3.21), P = 0.629, for TLR it was 1.09 (0.71 to 1.68); P = 0.700 and for binary in-stent restenosis it was 0.96 (0.48 to 1.93), P = 0.918. Compared to bare metal stents (BMS), DEB showed a lower LLL (− 0.26 mm (−0.51 to 0.01)) and a trend towards a lower MACE risk (RR 0.66 (0.43 to 1.02)). Conclusion Overall, drug-eluting balloons (+/− bare metal stent) are not superior to current standard therapies (BMS or drug eluting stent (DES)) in treating de novo coronary lesions. However, the performance of DEB seems to lie in between DES and BMS with a trend towards superiority over BMS alone. Therefore, DEB may be considered in patients with contraindications for DES. The heterogeneity between the included studies is a limitation of this meta-analysis; different drug-eluting balloons have been used. PMID:23657123
Lousuebsakul-Matthews, Vichuda; Thorpe, Donna L; Knutsen, Raymond; Beeson, W Larry; Fraser, Gary E; Knutsen, Synnove F
2014-01-01
Objective In contrast to non-vegetarians, vegetarians consume more legumes and meat analogues as sources of protein to substitute for meat intake. The present study aimed to assess the association between foods with high protein content (legumes, meat, meat analogues) by dietary pattern (vegetarians, non-vegetarians) and hip fracture incidence, adjusted for selected lifestyle factors. Design A prospective cohort of Adventist Health Study-2 (AHS-2) enrollees who completed a comprehensive lifestyle and dietary questionnaire between 2002 and 2007. Setting Every two years after enrolment, a short questionnaire on hospitalizations and selected disease outcomes including hip fractures was sent to these members. Subjects Respondents (n 33 208) to a baseline and a follow-up questionnaire. Results In a multivariable model, legumes intake of once daily or more reduced the risk of hip fracture by 64% (hazard ratio=0·36, 95% CI 0·21, 0·61) compared with those with legumes intake of less than once weekly. Similarly, meat intake of four or more times weekly was associated with a 40% reduced risk of hip fracture (hazard ratio=0·60, 95% CI 0·41, 0·87) compared with those whose meat intake was less than once weekly. Furthermore, consumption of meat analogues once daily or more was associated with a 49% reduced risk of hip fracture (hazard ratio=0·51, 95% CI 0·27, 0·98) compared with an intake of less than once weekly. Conclusions Hip fracture incidence was inversely associated with legumes intake and, to a lesser extent, meat intake, after accounting for other food groups and important covariates. Similarly, a high intake of meat analogues was associated with a significantly reduced risk of hip fracture. PMID:24103482
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiyosue, Hiro, E-mail: hkiyosue@oita-med.ac.jp; Okahara, Mika; Yamashita, Masanori
Percutaneous transluminal balloon angioplasty (PTA) has been used in the treatment of critical stenosis of the intracranial vertebrobasilar artery (VBA). PTA of the intracranial VBA carries the risk of fatal complications such as arterial dissection or acute occlusion as well as postoperative restenosis. The estimated risk of periprocedural complications and restenosis were approximately 20% and 27%. The use of recently developed stents could prevent these problems of PTA. We present two cases of restenosis of the intracranial VBA after PTA which stenoses were successfully retreated with endovascular stenting using flexible coronary stents without any complications. Neither restenosis nor other recurrentmore » symptoms were observed during the 4- and 6-month follow-up period. Reviewing the literature of 33 cases and our 2 cases, the overall complication rates related to stenting and restenosis were 5.6% and 7.8%. Endovascular stenting for the treatment of intracranial VBA can reduce the risk of arterial dissection and restenosis.« less
Photodynamic therapy for Barrett's esophagus using a 20-mm diameter light-delivery balloon
NASA Astrophysics Data System (ADS)
Panjehpour, Masoud; Overholt, Bergein F.; Phan, Mary N.; Haydek, John M.; Robinson, Amy R.
2002-06-01
Background and Objective: Patients with high grade dysplasia (HGD) in Barrett's esophagus are at a high risk for developing esophageal adenocarcinoma. Esophagectomy is the standard treatment for such patients. The objective of this study was to evaluate the safety and efficacy of photodynamic therapy (PDT) using an improved light delivery balloon for ablation of Barrett's esophagus with high grade dysplasia and/or early cancer. Materials and Methods: 20 patients with HGD or early cancer (19 with HGD, 1 with T1 cancer) received 2 mg/kg of porfimer sodium, intravenously. Two to three days after the injection, laser light was delivered using a cylindrical diffuser inserted inside a 20-mm diameter reflective esophageal PDT balloon. Initially, the balloon was inflated to a pressure of 80 mm Hg. The balloon pressure was gradually reduced to 30 mm Hg. A KTP/dye laser at 630 nm was used as the light source. Light dose of 115 J/cm was delivered at an intensity of 270 mw/cm. Nodules were pre- treated with an extra 50 J/cm using a short diffuser inserted through the scope. Patients were maintained on PPI therapy to keep the gastric pH higher than 4. Eighteen patients required one treatment, while two patients were treated twice. Follow-up consisted of endoscopy with four quadrant biopsies at every 2 cm of the treated area. Thermal ablation was used to treat small residual islands on the follow-ups. The follow-up endoscopies ranged from 6 to 17 months. Results: On follow-up endoscopy, 12 patients had complete replacement of their Barrett's mucosa with neosquamous mucosa. Five patients had residual non-dysplastic Barrett's mucosa, one had indefinite dysplasia, two had low grad dysplasia. There were no residual HGD or cancers. The average length of Barrett's was reduced from 5.4 cm to 1.2 cm. High balloon pressure resulted in wide variation in PDT response among patients. Lower balloon pressures resulted in more consistent destruction of Barrett's mucosa among patients. Five patients developed strictures which responded well to dilations. One patient developed atrial fibrillation which responded to medications. Conclusions: Photodynamic therapy using a 20 mm diameter balloon was effective for ablation of high grade dysplasia and early cancer in Barrett's esophagus. Low balloon inflation pressure was a critical parameter in producing consistent tissue destruction.
Lifting options for stratospheric aerosol geoengineering: advantages of tethered balloon systems.
Davidson, Peter; Burgoyne, Chris; Hunt, Hugh; Causier, Matt
2012-09-13
The Royal Society report 'Geoengineering the Climate' identified solar radiation management using albedo-enhancing aerosols injected into the stratosphere as the most affordable and effective option for geoengineering, but did not consider in any detail the options for delivery. This paper provides outline engineering analyses of the options, both for batch-delivery processes, following up on previous work for artillery shells, missiles, aircraft and free-flying balloons, as well as a more lengthy analysis of continuous-delivery systems that require a pipe connected to the ground and supported at a height of 20 km, either by a tower or by a tethered balloon. Towers are shown not to be practical, but a tethered balloon delivery system, with high-pressure pumping, appears to have much lower operating and capital costs than all other delivery options. Instead of transporting sulphuric acid mist precursors, such a system could also be used to transport slurries of high refractive index particles such as coated titanium dioxide. The use of such particles would allow useful experiments on opacity, coagulation and atmospheric chemistry at modest rates so as not to perturb regional or global climatic conditions, thus reducing scale-up risks. Criteria for particle choice are discussed, including the need to minimize or prevent ozone destruction. The paper estimates the time scales and relatively modest costs required if a tethered balloon system were to be introduced in a measured way with testing and development work proceeding over three decades, rather than in an emergency. The manufacture of a tether capable of sustaining the high tensions and internal pressures needed, as well as strong winds, is a significant challenge, as is the development of the necessary pumping and dispersion technologies. The greatest challenge may be the manufacture and launch of very large balloons, but means have been identified to significantly reduce the size of such balloons or aerostats.
The Accordion Sign in the Transplant Ureter: Ramifications During Balloon Dilation of Strictures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kriegshauser, J. Scott, E-mail: skriegshauser@mayo.edu; Naidu, Sailen G.; Chang, Yu-Hui H.
PurposeThis study was designed to demonstrate the accordion sign within the transplant ureter and evaluate its ramifications during balloon dilation of strictures.MethodsA retrospective electronic chart and imaging review included demographic characteristics, procedure reports, and complications of 28 renal transplant patients having ureteral strictures treated with percutaneous balloon dilation reported in our transplant nephrology database during an 8-year period. The accordion sign was deemed present or absent on the basis of an imaging review and was defined as present when a tortuous ureter became kinked and irregular when foreshortened after placement of a wire or a catheter. Procedure-related urine leaks weremore » categorized as occurring at the stricture if within 2 cm; otherwise, they were considered away from the stricture.ResultsThe accordion sign was associated with a significantly greater occurrence of leaks away from the stricture (P = 0.001) but not at the stricture (P = 0.34).ConclusionsThe accordion sign is an important consideration when performing balloon dilation procedures on transplant ureteral strictures, given the increased risk of leak away from the stricture. Its presence should prompt additional care during wire and catheter manipulations.« less
DeSantis, Stacia; Toole, J. Matthew; Kratz, John M.; Uber, Walter E.; Wheat, Margaret J.; Stroud, Martha R.; Ikonomidis, John S.; Spinale, Francis G.
2011-01-01
Background Aprotinin was a commonly utilized pharmacological agent for homeostasis in cardiac surgery but was discontinued resulting in the extensive use of lysine analogues. This study tested the hypothesis that early post-operative adverse events and blood product utilization would affected in this post-aprotinin era. Methods/Results Adult patients (n=781) undergoing coronary artery bypass (CABG), valve replacement, or both from November 1, 2005-October 31, 2008 at a single institution were included. Multiple logistic regression modeling and propensity scoring were performed on 29 pre-operative and intra-operative variables in patients receiving aprotinin (n=325) or lysine analogues (n=456). The propensity adjusted relative risk (RR;95% confidence interval;CI) for the intra-operative use of packed red blood cells (RR:0.75;CI:0.57–0.99), fresh frozen plasma (RR:0.37;0.21–0.64), and cryoprecipitate (RR:0.06;CI:0.02–0.22) were lower in the aprotinin versus lysine analogue group (all p<0.05). The risk for mortality (RR:0.53;CI:0.16–1.79) and neurological events (RR:0.87;CI:0.35–2.18) remained similar between groups, whereas a trend for reduced risk for renal dysfunction was observed in the aprotinin group. Conclusions In the post-aprotinin era with the exclusive use of lysine analogues, the relative risk of early post-operative outcomes such as mortality and renal dysfunction have not improved, but the risk for the intra-operative use of blood products has increased. Thus, improvements in early post-operative outcomes have not been realized with the discontinued use of aprotinin, but rather increased blood product utilization has occurred with the attendant costs and risks inherent with this strategy. PMID:21911820
Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik; Holmstrup, Palle; Helqvist, Steffen; Tolker-Nielsen, Tim; Givskov, Michael; Hansen, Peter Riis
2015-01-01
Periodontitis is a chronic, bacterially-induced inflammatory disease of the tooth-supporting tissues, which may result in transient bacteremia and a systemic inflammatory response. Periodontitis is associated with coronary artery disease independently of established cardiovascular risk factors, and translocation of bacteria from the oral cavity to the coronary arteries may play a role in the development of coronary artery disease. Very few studies have used angioplasty balloons for in vivo sampling from diseased coronary arteries, and with varying results. Therefore, the aim of this study was to assess if bacterial DNA from primarily oral bacteria could be detected on coronary angioplasty balloons by use of an optimized sampling process combined with an internally validated sensitive polymerase chain reaction (PCR) assay. Coronary angioplasty balloons and control samples from a total of 45 unselected patients with stable angina, unstable angina/non-ST elevation myocardial infarction, and ST-elevation myocardial infarction (n = 15 in each group) were collected and analyzed using a PCR assay with high sensitivity and specificity for 16S rRNA genes of the oral microbiome. Despite elimination of extraction and purification steps, and demonstration of sensitivity levels of 25–125 colony forming units (CFU), we did not detect bacterial DNA from any of the coronary angioplasty balloons. A subsequent questionnaire indicated that the prevalence of periodontitis in the study cohort was at least 39.5%. Although coronary angioplasty balloons are unlikely to be useful for detection of bacteria with current PCR techniques in unselected patients with coronary artery disease, more studies are warranted to determine the extent to which bacteria contribute to atherosclerosis and its clinical manifestations and whether the presence of bacteria in the arteries is a transient phenomenon. PMID:26695491
Is endoscopic papillary large balloon dilation safe for treating large CBD stones?
Shim, Chan Sup; Kim, Ji Wan; Lee, Tae Yoon; Cheon, Young Koog
2016-01-01
In recent years, endoscopic papillary large balloon dilation (EPLBD) with endoscopic sphincterotomy (EST) has been shown to be an effective technique for the removal of large or difficult common bile duct (CBD) stones, as an alternative to EST. Reviewing the literature published since 2003, it is understood that EPLBD has fewer associated overall complications than EST. Bleeding occurred less frequently with EPLBD than with EST. There was no significant difference in postendoscopic retrograde cholangiopancreatography pancreatitis or perforation. Recent accumulated results of EPLBD with or even without EST suggest that it is a safe and effective procedure for the removal of large or difficult bile duct stones without any additional risk of severe adverse events, when performed under appropriate guidelines. Since use of a larger balloon can tear the sphincter as well as the bile duct, possibly resulting in bleeding and perforation, a balloon size that is equal to or smaller in diameter than the diameter of the native distal bile duct is recommended. The maximum transverse diameter of the stone and the balloon-stone diameter ratio have a tendency to affect the success or failure of complete removal of stones by large balloon dilation to prevent adverse effects such as perforation and bleeding. One should take into account the size of the native bile duct, the size and burden of stones, the presence of stricture of distal bile duct, and the presence of the papilla in or adjacent to a diverticulum. Even though the results of EPLBD indicate that it is a relatively safe procedure in patients with common duct stones with a dilated CBD, the recommended guidelines should be followed strictly for the prevention of major adverse events such as bleeding and perforation.
Ramos, R V; Monteiro-Steagall, B P; Steagall, P V M
2014-04-01
The aim of this study was to report the management and complications of anaesthesia in dogs undergoing balloon valvuloplasty. A retrospective review of medical records of dogs that were diagnosed with pulmonic stenosis and undergoing balloon valvuloplasty between 2000 and 2012. Thirty-nine cases were identified (28 males and 11 females). Median (range) age and bodyweight was 6 (4 to 48) months and 11·5 (2·0 to 30·3) kg, respectively. The most commonly represented breeds included mixed breed (n = 7, 17·9%) and English bulldog (n = 6, 15·3%). Anaesthesia was induced most commonly with intravenous administration of ketamine-diazepam (n = 8, 20·5%), propofol-diazepam (n = 8, 20·5%), or propofol-midazolam-lidocaine (n = 6, 15·4%), and maintained with isoflurane in combination with fentanyl or lidocaine. Anaesthetic and surgery times (mean ± sd) were 268·5 ±54 minutes and 193·2 ±50 minutes, respectively. The most common intraoperative complications were hypotension (n = 19, 48·7%), bradycardia (n = 8, 20·5%) and desaturation (n = 7, 17·9%). Cardiac arrhythmias were observed in 21 (53·8%) dogs. Death occurred in one (2·6%) dog due to severe hypotension after ballooning followed by cardiac arrest. Successful anaesthesia can be performed in young dogs with pulmonic stenosis undergoing balloon valvuloplasty. Management of anaesthesia requires intense monitoring and immediate treatment of complications. Anaesthetic risk increases during ballooning and may result in cardiac arrest. © 2014 British Small Animal Veterinary Association.
Lovallo, William R.; Enoch, Mary-Anne; Yechiam, Eldad; Glahn, David C.; Acheson, Ashley; Sorocco, Kristen H.; Hodgkinson, Colin A.; Kim, Bojeong; Cohoon, Andrew J.; Vincent, Andrea S.; Goldman, David
2014-01-01
Background Central serotonergic (5-HT) function is implicated in pathways to alcohol dependence, including dysphoria manifested by symptoms of anxiety and depression. However, little is known about genetic variation in central 5-HT function and its potential impact on temperament and behavior in persons with a family history of alcoholism (FH+). Methods We tested 314 healthy young adults (23.5 yr of age, 57% female; 193 FH− and 121 FH+) enrolled in the Oklahoma Family Health Patterns project, a study of alcoholism risk in relation to temperament and behavioral dyscontrol. Dysphoria was assessed using the Eysenck neuroticism and Beck depression scales, and Cloninger’s Tridimensional Personality Questionnaire. Risk taking was assessed with the Iowa Gambling Task (IGT) and Balloon Analogue Response Task (BART). All subjects were genotyped for a functional polymorphism (5-HTTLPR) in the promoter region of the serotonin transporter gene (SCL6A4). Results FH+ subjects with the gain-of-function 5-HTTLPR genotype scored higher in neuroticism, harm avoidance, and symptoms of Depression (p values ≤ .03). No effect of 5-HTTLPR genotype was seen in FH−. FH+ carriers of the gain-of-function 5-HTTLPR genotype played to minimize their frequency of losses in the IGT whereas FH− carriers played a balanced strategy (p < .003). No 5-HTTLPR effects were seen in the BART. Results were unaffected by sex, education, drug use, and antisocial characteristics. Conclusions The functional 5-HTTLPR polymorphism predicted significant variation in negative moods and poorer affect regulation in FH+ persons, with possible consequences for behavior, as seen in a simulated gambling task. This pattern may contribute to a drinking pattern that is compensatory for such affective tendencies. PMID:24796636
Lovallo, William R; Enoch, Mary-Anne; Yechiam, Eldad; Glahn, David C; Acheson, Ashley; Sorocco, Kristen H; Hodgkinson, Colin A; Kim, Bojeong; Cohoon, Andrew J; Vincent, Andrea S; Goldman, David
2014-06-01
Central serotonergic (5-HT) function is implicated in pathways to alcohol dependence, including dysphoria manifested by symptoms of anxiety and depression. However, little is known about genetic variation in central 5-HT function and its potential impact on temperament and behavior in persons with a family history of alcoholism (FH+). We tested 314 healthy young adults (23.5 years of age, 57% female; 193 FH- and 121 FH+) enrolled in the Oklahoma Family Health Patterns project, a study of alcoholism risk in relation to temperament and behavioral dyscontrol. Dysphoria was assessed using the Eysenck neuroticism and Beck depression scales, and Cloninger's Tridimensional Personality Questionnaire. Risk taking was assessed with the Iowa Gambling Task (IGT) and Balloon Analogue Response Task (BART). All subjects were genotyped for a functional polymorphism (5-HTTLPR) in the promoter region of the serotonin transporter gene (SLC6A4). FH+ subjects with the gain-of-function 5-HTTLPR genotype scored higher in neuroticism, harm avoidance, and symptoms of depression (p-values ≤ 0.03). No effect of 5-HTTLPR genotype was seen in FH-. FH+ carriers of the gain-of-function 5-HTTLPR genotype played to minimize their frequency of losses in the IGT, whereas FH- carriers played a balanced strategy (p < 0.003). No 5-HTTLPR effects were seen in the BART. Results were unaffected by sex, education, drug use, and antisocial characteristics. The functional 5-HTTLPR polymorphism predicted significant variation in negative moods and poorer affect regulation in FH+ persons, with possible consequences for behavior, as seen in a simulated gambling task. This pattern may contribute to a drinking pattern that is compensatory for such affective tendencies. Copyright © 2014 by the Research Society on Alcoholism.
Aparício, Dayse Pereira da Silva; Otoch, José Pinhata; Montero, Edna Frasson de Souza; Artifon, Everson Luiz de Almeida
2016-01-01
The most common biliary complication after liver transplantation is anastomotic stricture (AS) and it can occur isolated or in combination with other complications. Liver graft from a cadaveric donor or a living donor has an influence on the incidence of biliary strictures as well as on the response to endoscopic treatment. Endoscopic treatment using balloon dilation and insertion of biliary stents by endoscopic retrograde cholangiopancreatography (ERCP) is the initial approach to these complications. Aim The aim of this article is to compare different endoscopic techniques to treat post-liver transplantation biliary strictures. Methods The search was carried out on MEDLINE, EMBASE, Scielo-LILACS and Cochrane Library databases through June 2015. A total of 1100 articles were retrieved. Ten clinical trials were analyzed, and seven were included in the meta-analysis. Conclusions The endoscopic treatment of AS was equally effective when compared the use of fully covered self-expandable metal stents (FCSEMS) vs. plastic stents, but the use of FCSEMS was associated with a lower complication risk. The treatment of AS with balloon dilation or balloon dilation associated with plastic stents presented similar results. Deceased donor liver transplantation reduced the risk of biliary stenosis and the endoscopic treatment in these patients was more effective when compared with Living donor liver transplantation. PMID:29026597
Hardell, Lennart; Carlberg, Michael; Hansson Mild, Kjell
2006-02-01
The use of cellular and cordless telephones and the risk of brain tumours is of concern since the brain is a high exposure area. We present the results of a pooled analysis of two case-control studies on benign brain tumours diagnosed during 1997-2003 including answers from 1,254 (88%) cases and 2,162 (89%) controls aged 20-80 years. For acoustic neuroma, the use of analogue cellular phones gave an odds ratio (OR) of 2.9 and a 95% confidence interval (CI) of 2.0-4.3; for digital cellular phones, OR=1.5; 95% CI=1.1-2.1; and for cordless telephones, OR=1.5, 95% CI=1.04-2.0. The highest OR was found for analogue phones with a latency period of >15 years; OR=3.8, 95% CI=1.4-10. Regarding meningioma, the results were as follows: for analogue phones, OR=1.3, 95% CI=0.99-1.7; for digital phones, OR=1.1, 95% CI=0.9-1.3; and for cordless phones, OR=1.1, 95% CI=0.9-1.4. In the multivariate analysis, a significantly increased risk of acoustic neuroma was found with the use of analogue phones.
Saia, Francesco; Moretti, Carolina; Dall'Ara, Gianni; Ciuca, Cristina; Taglieri, Nevio; Berardini, Alessandra; Gallo, Pamela; Cannizzo, Marina; Chiarabelli, Matteo; Ramponi, Niccolò; Taffani, Linda; Bacchi-Reggiani, Maria Letizia; Marrozzini, Cinzia; Rapezzi, Claudio; Marzocchi, Antonio
2016-01-01
Background Whilst the majority of the patients with severe aortic stenosis can be directly addressed to surgical aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI), in some instances additional information may be needed to complete the diagnostic workout. We evaluated the role of balloon aortic valvuloplasty (BAV) as a bridge-to-decision (BTD) in selected high-risk patients. Methods Between 2007 and 2012, the heart team in our Institution required BTD BAV in 202 patients. Very low left ventricular ejection fraction, mitral regurgitation grade ≥ 3, frailty, hemodynamic instability, serious comorbidity, or a combination of these factors were the main drivers for this strategy. We evaluated how BAV influenced the final treatment strategy in the whole patient group and in each specific subgroup. Results Mean logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) was 23.5% ± 15.3%, age 81 ± 7 years. In-hospital mortality was 4.5%, cerebrovascular accident 1% and overall vascular complications 4% (0.5% major; 3.5% minor). Of the 193 patients with BTD BAV who survived and received a second heart team evaluation, 72.6% were finally deemed eligible for definitive treatment (25.4% for AVR; 47.2% for TAVI): 96.7% of patients with left ventricular ejection fraction recovery; 70.5% of patients with mitral regurgitation reduction; 75.7% of patients who underwent BAV in clinical hemodynamic instability; 69.2% of frail patients and 68% of patients who presented serious comorbidities. Conclusions Balloon aortic valvuloplasty can be considered as bridge-to-decision in high-risk patients with severe aortic stenosis who cannot be immediate candidates for definitive transcatheter or surgical treatment. PMID:27582761
Beall, Douglas P; Olan, Wayne J; Kakad, Priyanka; Li, Qianyi; Hornberger, John
2015-01-01
Vertebral compression fractures (VCFs) are the most common osteoporotic fractures and cause persistent pain, kyphotic deformity, weight loss, depression, reduced quality of life, and even death. Current surgical approaches for the treatment of VCF include vertebroplasty (VP) and balloon kyphoplasty (BK). The Kiva® VCF Treatment System (Kiva System) is a next-generation alternative surgical intervention in which a percutaneously introduced nitinol Osteo Coil guidewire is advanced through a deployment cannula and subsequently a PEEK Implant is implanted incrementally and fully coiled in the vertebral body. The Kiva System's effectiveness for the treatment of VCF has been evaluated in a large randomized controlled trial, the Kiva Safety and Effectiveness Trial (KAST). The Kiva System was non-inferior to BK with respect to pain reduction (70.8% vs. 71.8% in Visual Analogue Scale) and physical function restoration (38.1 % vs. 42.2% reduction in Oswestry Disability Index) while using less bone cement. The economic impact of the Kiva system has yet to be analyzed. To analyze hospital resource use and costs of the Kiva System over 2 years for the treatment of VCF compared to BK. A representative US hospital. Economic analysis of the KAST randomized trial, focusing on hospital resource use and costs. The analysis was conducted from a hospital perspective and utilized clinical data from KAST as well as unit-cost data from the published literature. The cost of initial VCF surgery, reoperation cost, device market cost, and other medical costs were compared between the Kiva System and BK. The relative risk reduction rate in adjacent-level fracture with Kiva [31.6% (95% CI: -22.5%, 61.9%)] demonstrated in KAST was used in this analysis. With 304 vertebral augmentation procedures performed in a representative U.S. hospital over 2 years, the Kiva System will produce a direct medical cost savings of $1,118 per patient and $280,876 per hospital. This cost saving with the Kiva System was attributable to 19 reduced adjacent-level fractures with the Kiva System. This study does not compare the Kiva System with VP or any other non-surgical procedures for the treatment of VCF. This first-ever economic analysis of the KAST data showed that the Kiva System for vertebral augmentation is hospital resource and cost saving over BK in a hospital setting over 2 years. These savings are attributable to reduced risk of developing adjacent-level fractures with the Kiva System compared to BK.
Ogami, Ryo; Nakahara, Toshinori; Hamasaki, Osamu; Araki, Hayato; Kurisu, Kaoru
2011-10-01
A rare complication of carotid artery stenting (CAS), prolonged reversible neurological symptoms with delayed cerebrospinal fluid (CSF) space enhancement on fluid attenuated inversion recovery (FLAIR) images, is associated with blood-brain barrier (BBB) disruption. We prospectively identified patients who showed CSF space enhancement on FLAIR images. Nineteen patients-5 acute-phase and 14 scheduled-underwent 21 CAS procedures. Balloon catheters were navigated across stenoses, angioplasty was performed using a neuroprotective balloon, and stents were placed with after dilation under distal balloon protection. CSF space hyperintensity or obscuration on FLAIR after versus before CAS indicated CSF space enhancement. Correlations with clinical factors were examined. CSF space was enhanced on FLAIR in 12 (57.1%) cases. Postprocedural CSF space enhancement was significantly related to age, stenosis rate, acute-stage procedure, and total occlusion time. All acute-stage CAS patients showed delayed enhancement. Only age was associated with delayed CSF space enhancement in scheduled CAS patients. Ischemic intolerance for severe carotid artery stenosis and temporary neuroprotective balloon occlusion, causing reperfusion injury, seem to be the main factors that underlie BBB disruption with delayed CSF space enhancement shortly after CAS, rather than sudden poststenting hemodynamic change. Our results suggest that factors related to hemodynamic instability or ischemic intolerance seem to be associated with post-CAS BBB vulnerability. Patients at risk for hemodynamic instability or with ischemic intolerance, which decrease BBB integrity, require careful management to prevent intracranial hemorrhagic and other post-CAS complications.
Koscielniak, Maciej; Rydzewska, Klara; Sedek, Grzegorz
2016-01-01
According to the dual-process theoretical perspective adopted in the presented research, the efficiency of deliberative processes in decision making declines with age, but experiential processes are relatively well-preserved. The age-related differences in deliberative and experiential processes in risky decision-making were examined in this research by applying the Balloon Analog Risk Task (BART). We analyzed the influence of age on risk acceptance and decision-making performance in two age groups of female participants (younger adults, n = 81; older adults, n = 76), with additional experimental manipulation of initial risk perception. We predicted and confirmed that aging significantly worsens performance on the behavioral BART measures due to age-related decline in deliberative processes. Older participants were found to exhibit significantly higher risk aversion and lower BART performance, and the effect of age was mediated by cognitive (processing speed) and motivational (need for cognitive closure) mechanisms. Moreover, older adults adapt to the initial failure (vs. success) similarly, as younger adults due to preserved efficiency of experiential processes. These results suggest future directions for minimizing negative effects of aging in risky decision-making and indicate compensatory processes, which are preserved during aging. PMID:27199877
NASA Astrophysics Data System (ADS)
Li, Lin; Lin, Zijing; Cazzell, Mary; Liu, Hanli
2013-03-01
Investigation of the reliability and reproducibility of the hemodynamic response is important for interpretation and understanding of the results of functional near-infrared spectroscopy (fNIRS). It measures optical signals absorbed by the brain tissue and reflects the neuronal activities indirectly. Here we described an fNIRS study measured in the prefrontal region (Brodman area 9, 10, part of 46)to examine the risk decision-making behavior in nine young adults. The Balloon Analog Risk Task (BART) is widely used to test the level of risk taking ability in the field of psychology. BART was a protocol utilized in this study to evoke a risk-taking environment with a gambling-like balloon game in each subject. Specifically, we recorded the brain oxygenated-hemoglobin (HbO) and deoxygenated-hemoglobin (HHb) changes during the two repeated measurements within a time interval of 3 weeks. The results demonstrate that the changes in HbO2 amplitudes have high reliability at the group level, and that the spatial patterns of the tomographic images have high reproducibility in size and a moderate degree of overlap. Overall, this study confirms that the hemodynamic response to risk decision-making (i.e., BART) seen by fNIRS is highly reliable and reproducible.
Jentsch, James David; Woods, Jason A; Groman, Stephanie M; Seu, Emanuele
2010-07-01
The tendency for some individuals to partake in high-risk behaviors (eg, substance abuse, gambling, risky sexual activities) is a matter of great public health concern, yet the characteristics and neural bases of this vulnerability are largely unknown. Recent work shows that this susceptibility can be partially predicted by laboratory measures of reward seeking under risk, including the Balloon Analog Risk Task. Rats were trained to respond on two levers: one of which (the 'add lever') increased the size of a potential food reward and a second (the 'cash-out lever') that led to delivery of accrued reward. Crucially, each add-lever response was also associated with a risk that the trial would fail and no reward would be delivered. The relative probabilities that each add-lever press would lead to an addition food pellet or to trial failure (risk) were orthogonally varied. Rats exhibited a pattern of responding characteristic of incentive motivation and risk aversion, with a subset of rats showing traits of high-risk taking and/or suboptimal responding. Neural inactivation studies suggest that the orbitofrontal cortex supports greater reward seeking in the presence or absence of risk, whereas the medial prefrontal cortex is required for optimization of patterns of responding. These findings provide new information about the neural circuitry of decision making under risk and reveal new insights into the biological determinants of risk-taking behaviors that may be useful in developing biomarkers of vulnerability.
García-Suárez, Julio; de Miguel, Dunia; Krsnik, Isabel; Bañas, Helena; Arribas, Ignacio; Burgaleta, Carmen
2005-12-01
The aims of this study were to evaluate the clinical characteristics of HIV-negative patients affected by lymphoproliferative disorders (LPD) who developed progressive multifocal leukoencephalopathy (PML), to delineate the risk factors, and to analyze whether the new antineoplastic therapies are changing the natural history of this infectious disease. We retrospectively analyzed 46 cases with confirmed LPD-associated PML published from 1958 to 2004. Patients were stratified according to two different time periods: group A included patients diagnosed before 1989, and group B included patients diagnosed since 1990, after introduction of purine analogues. Group A patients (n = 22) had received alkylating agents and/or radiotherapy, and the majority (63.6%) had advanced Hodgkin disease. At univariate analysis, uncontrolled Hodgkin disease was the only risk factor for PML. In group B patients (n = 24), the most frequent treatments received were purine analogues (58.3%) and high-dose therapy with hematopoietic stem cell transplantation (33.3%; HDT/HSCT). B-cell chronic lymphocytic leukemia (45.8%) and aggressive non-Hodgkin lymphoma (24.9%) were the most frequent underlying LPDs. Patients treated with purine analogues were more likely to have active LPD, lower CD4 cell counts, and to be older and male than were HSCT recipients. The median interval from purine analogues or HDT/HSCT to PML was 11 months. In HDT/HSCT recipients, this interval was delayed for 10 months when peri-transplantation rituximab was used. Univariate analysis identified age >55 years, male sex, and CD4 cell counts
The Need for Analogue Missions in Scientific Human and Robotic Planetary Exploration
NASA Technical Reports Server (NTRS)
Snook, K. J.; Mendell, W. W.
2004-01-01
With the increasing challenges of planetary missions, and especially with the prospect of human exploration of the moon and Mars, the need for earth-based mission simulations has never been greater. The current focus on science as a major driver for planetary exploration introduces new constraints in mission design, planning, operations, and technology development. Analogue missions can be designed to address critical new integration issues arising from the new science-driven exploration paradigm. This next step builds on existing field studies and technology development at analogue sites, providing engineering, programmatic, and scientific lessons-learned in relatively low-cost and low-risk environments. One of the most important outstanding questions in planetary exploration is how to optimize the human and robotic interaction to achieve maximum science return with minimum cost and risk. To answer this question, researchers are faced with the task of defining scientific return and devising ways of measuring the benefit of scientific planetary exploration to humanity. Earth-based and spacebased analogue missions are uniquely suited to answer this question. Moreover, they represent the only means for integrating science operations, mission operations, crew training, technology development, psychology and human factors, and all other mission elements prior to final mission design and launch. Eventually, success in future planetary exploration will depend on our ability to prepare adequately for missions, requiring improved quality and quantity of analogue activities. This effort demands more than simply developing new technologies needed for future missions and increasing our scientific understanding of our destinations. It requires a systematic approach to the identification and evaluation of the categories of analogue activities. This paper presents one possible approach to the classification and design of analogue missions based on their degree of fidelity in ten key areas. Various case studies are discussed to illustrate the approach.
Initial experience of coiling cerebral aneurysms using the new Comaneci device
Lawson, Aimee Louise Deborah; Chandran, Arun; Puthuran, Mani; Goddard, Tony; Nahser, Hans; Patankar, Tufail
2015-01-01
We present our initial patient experience with an innovative temporary bridging device, the Comaneci (Rapid Medical, Israel), to assist in the coiling of cerebral aneurysms. The Comaneci device confers the same benefits as balloon remodeling but without the risks of parent artery occlusion. This alleviates time pressure on the clinician, and could reduce the risk of parent artery thrombosis. Three patients were treated with the Comaneci device. Two patients had acute ruptured posterior communicating aneurysms and one patient was treated electively for a carotico-ophthalmic aneurysm. Excellent occlusion of all three aneurysms was obtained. One patient developed a distal middle cerebral artery clot, that was treated with intravenous aspirin, with minor neurological consequences. These early results show that the Comaneci device can be used to achieve good cerebral aneurysm occlusion. Vessel patency is maintained throughout the procedure with potential advantages over conventional balloon assisted coiling. PMID:26123460
Levin, Ricardo; Degrange, Marcela; Del Mazo, Carlos; Tanus, Eduardo; Porcile, Rafael
2012-01-01
BACKGROUND: The calcium sensitizer levosimendan has been used in cardiac surgery for the treatment of postoperative low cardiac output syndrome (LCOS) and difficult weaning from cardiopulmonary bypass (CPB). OBJECTIVES: To evaluate the effects of preoperative treatment with levosimendan on 30-day mortality, the risk of developing LCOS and the requirement for inotropes, vasopressors and intra-aortic balloon pumps in patients with severe left ventricular dysfunction. METHODS: Patient with severe left ventricular dysfunction and an ejection fraction <25% undergoing coronary artery bypass grafting with CPB were admitted 24 h before surgery and were randomly assigned to receive levosimendan (loading dose 10 μg/kg followed by a 23 h continuous infusion of 0.1μg/kg/min) or a placebo. RESULTS: From December 1, 2002 to June 1, 2008, a total of 252 patients were enrolled (127 in the levosimendan group and 125 in the control group). Individuals treated with levosimendan exhibited a lower incidence of complicated weaning from CPB (2.4% versus 9.6%; P<0.05), decreased mortality (3.9% versus 12.8%; P<0.05) and a lower incidence of LCOS (7.1% versus 20.8%; P<0.05) compared with the control group. The levosimendan group also had a lower requirement for inotropes (7.9% versus 58.4%; P<0.05), vasopressors (14.2% versus 45.6%; P<0.05) and intra-aortic balloon pumps (6.3% versus 30.4%; P<0.05). CONCLUSION: Patients with severe left ventricle dysfunction (ejection fraction <25%) undergoing coronary artery bypass grafting with CPB who were pretreated with levosimendan exhibited lower mortality, a decreased risk for developing LCOS and a reduced requirement for inotropes, vasopressors and intra-aortic balloon pumps. Studies with a larger number of patients are required to confirm whether these findings represent a new strategy to reduce the operative risk in this high-risk patient population. PMID:23620700
Endoscopic Balloon Dilatation of Benign Esophageal Stricture—A Nonhazardous Procedure?
Borgström, Anders; Fork, Frans-Thomas; Lövdahl, Eje
1994-01-01
Balloon dilatation of benign esophageal strictures has been widely used since its introduction. We have performed 224 dilatation procedures in 52 patients. Dilatation was done as an outpatient procedure. Strictures were due to reflux esophagitis in 25 patients, anastomatic stenosis in 6, achalasia in 5, complications of sclerotherapy in 5, corrosive lesions in 3, and long-standing nasogastric intubation in 2. The cause was unknown in 6 cases. The intention was to dilate all strictures up to 20 mm. Three major complications occurred, and one of these patients died. The risk of perforation seems to be higher after repeated procedures than during the first one. PMID:18493348
Flight Validation of Mars Mission Technologies
NASA Technical Reports Server (NTRS)
Eberspeaker, P. J.
2000-01-01
Effective exploration and characterization of Mars will require the deployment of numerous surface probes, tethered balloon stations and free-flying balloon systems as well as larger landers and orbiting satellite systems. Since launch opportunities exist approximately every two years it is extremely critical that each and every mission maximize its potential for success. This will require significant testing of each system in an environment that simulates the actual operational environment as closely as possible. Analytical techniques and laboratory testing goes a long way in mitigating the inherent risks associated with space exploration, however they fall sort of accurately simulating the unpredictable operational environment in which these systems must function.
Xie, C B; Chan, M Y; Teo, S G; Low, A F; Tan, H C; Lee, C H
2011-11-01
There is a paucity of data on acute myocardial infarction (AMI) in young Asian women and of comparative data among various ethnic groups with respect to risk factor profile and clinical outcomes. We present a comprehensive overview of the clinical characteristics of young Asian women with AMI and a comparative analysis among Chinese, Malay and Indian women in a multi-ethnic Asian country. We studied 45 Asian female patients aged 50 years and below who were admitted to our hospital with a diagnosis of ST-segment elevation myocardial infarction (STEMI) or non-ST-segment elevation myocardial infarction (NSTEMI). Overall, diabetes mellitus, hypertension and hyperlipidaemia were prevalent in the study population. Hyperlipidaemia was more prevalent among Indian patients, while diabetes mellitus was more common among Malay patients. Only a minority of the study patients were current smokers. Among the 20 patients admitted with STEMI, 17 (85 percent) received urgent reperfusion therapy. The mean symptom-to-balloon time and door-to-balloon time for the Malay patients were longer compared to those for other ethnic groups. Among the 25 patients admitted with NSTEMI, 12 (48 percent) underwent coronary revascularisation therapy. The average duration of hospital stay was 4 +/- 4.1 days, with no significant difference observed among the various ethnic groups. Many young Asian women with AMI have identifiable risk factors that are different from those found in the Western population. There seems to be an ethnic effect on the prevalence of these risk factors and door-to-balloon time.
Peak Sound Pressure Levels and Associated Auditory Risk from an H[subscript 2]-Air "Egg-Splosion"
ERIC Educational Resources Information Center
Dolhun, John J.
2016-01-01
The noise level from exploding chemical demonstrations and the effect they could have on audiences, especially young children, needs attention. Auditory risk from H[subscript 2]- O2 balloon explosions have been studied, but no studies have been done on H[subscript 2]-air "eggsplosions." The peak sound pressure level (SPL) was measured…
Percutaneous transluminal balloon dilatation of the mitral valve in pregnancy.
Smith, R; Brender, D; McCredie, M
1989-06-01
Pregnancy can cause life threatening complications in women with mitral stenosis, and there is a substantial risk of fetal death if valvotomy under cardiopulmonary bypass is required. A patient is described in whom pulmonary oedema developed after delivery of her first child by caesarean section 13 months previously. Subsequent cardiac catheterisation showed severe mitral stenosis (valve area 0.96 cm2, valve gradient 12 mm Hg, pulmonary artery pressure 30/16 mm Hg). Before valvotomy could be performed the patient again became pregnant and presented in pulmonary oedema at twenty two weeks' gestation. Medical treatment was unsuccessful and she underwent percutaneous transluminal balloon dilatation of the mitral valve. This increased the valve area to 1.78 cm2 and reduced the transmitral gradient to 6 mm Hg. The procedure was uncomplicated, and she remained symptom free on no medication. She delivered vaginally at 37 weeks' gestation. Percutaneous transluminal balloon dilatation of the mitral valve is a safe and effective alternative to mitral valvotomy in pregnancy.
Costantini, C; Sampaolesi, A; Serra, C M; Pacheco, G; Neuburger, J; Conci, E; Haendchen, R V
1991-07-01
Synchronized coronary venous retroperfusion was used during coronary balloon angioplasty to support the ischemic myocardium of 20 patients with unstable angina and anatomy at high risk of a coronary event. Hemodynamics and left ventricular function were the major end points of the study. Coronary venous catheterization and retroperfusion were successfully performed in 15 patients. The target vessel was an unprotected left main artery in 2, left anterior descending artery in 10, left circumflex coronary artery in 1 and right coronary artery in 2 patients. A nonsupported balloon inflation (mean 44 +/- 13 s) was compared with a later retroperfusion-supported inflation (mean 145 +/- 21 s). Right anterior oblique left ventriculograms, aortic blood pressure, pulmonary artery pressure and thermodilution cardiac output were obtained before and during peak untreated and treated balloon inflations and on completion of angioplasty. All patients had either a baseline left ventricular ejection fraction less than 0.40 or greater than 40% of contracting myocardium estimated to be at risk for severe ischemia during angioplasty. The cardiac (liters/min per m2) and stroke work (g.m/m2) indexes decreased from mean baseline values of 2.5 +/- 0.52 and 52 +/- 15 to 1.7 +/- 0.47 and 27 +/- 12 (mean +/- SD), respectively, during nonsupported balloon inflations but decreased only to 2.1 +/- 0.52 (p less than 0.01 vs. nonsupported) and to 36 +/- 14 (p = 0.01 vs. nonsupported), respectively, during retroperfusion-supported inflations. Ejection fraction (n = 8) decreased from a baseline value of 55 +/- 13% to 27 +/- 7.3% during nonsupported inflations but only to 39 +/- 10% during retroperfusion-supported inflations (p = 0.01 vs. nonsupported). Regional wall motion (area change) in the ischemic (target) region was reduced from a baseline value of 49 +/- 17% to 11 +/- 16% during nonsupported inflations but only to 27 +/- 15% during retroperfusion-supported inflations (p less than 0.01 vs. nonsupported). All but two patients had a favorable hemodynamic response to retroperfusion. There were no serious adverse effects related to the procedures and no hospital deaths. It is concluded from this preliminary study that coronary venous retroperfusion appears to be safe, to provide hemodynamic support and to improve left ventricular function during angioplasty in patients with unstable angina and anatomy at high risk of a coronary event.
Genie in a blotter: A comparative study of LSD and LSD analogues' effects and user profile.
Coney, Leigh D; Maier, Larissa J; Ferris, Jason A; Winstock, Adam R; Barratt, Monica J
2017-05-01
This study aimed to describe self-reported patterns of use and effects of lysergic acid diethylamide (LSD) analogues (AL-LAD, 1P-LSD, and ETH-LAD) and the characteristics of those who use them. An anonymous self-selected online survey of people who use drugs (Global Drug Survey 2016; N = 96,894), which measured perceived drug effects of LSD and its analogues. Most LSD analogue users (91%) had also tried LSD. The proportion of U.K. and U.S. respondents reporting LSD analogue use in the last 12 months was higher than for LSD only. LSD analogue users described the effects as psychedelic (93%), over half (55%) obtained it online, and almost all (99%) reported an oral route of administration. The modal duration (8 hr) and time to peak (2 hr) of LSD analogues were not significantly different from LSD. Ratings for pleasurable high, strength of effect, comedown, urge to use more drugs, value for money, and risk of harm following use were significantly lower for LSD analogues compared with LSD. LSD analogues were reported as similar in time to peak and duration as LSD but weaker in strength, pleasurable high, and comedown. Future studies should seek to replicate these findings with chemical confirmation and dose measurement. Copyright © 2017 John Wiley & Sons, Ltd.
Variation in hospital rates of intraaortic balloon pump use in coronary artery bypass operations.
Ghali, W A; Ash, A S; Hall, R E; Moskowitz, M A
1999-02-01
Little is known about regional patterns of intraaortic balloon pump (IABP) use in coronary artery bypass graft (CABG) operations. Our objectives were (1) to identify clinical variables associated with IABP use, and (2) to examine risk-adjusted rates of IABP use for 12 Massachusetts hospitals performing CABG operations. We used hospital discharge data to identify 6944 CABG surgical cases. Logistic regression was used to identify clinical variables associated with IABP use, and the resulting multivariate model was then used to risk adjust hospital rates of IABP use. The IABP was used in 13.4% of the CABG surgical cases. The clinical variables independently associated with IABP use were cardiogenic shock, same admission angioplasty, prior CABG operation, cardiac arrest, congestive heart failure, recent myocardial infarction, and urgent admission status. Risk-adjusted rates of IABP use varied widely across hospitals from 7.8% to 20.8% (p < 0.0001). Hospital rates of IABP use vary considerably in Massachusetts. This practice variation may be related to the persistent uncertainty regarding the precise clinical indications for the IABP in this patient population.
Sharma, Shikha; Ahmad, Shahzad; Faraz Khan, Mohemmed; Parvez, Suhel; Raisuddin, Sheikh
2018-06-21
Bisphenol A (BPA) is known for endocrine disrupting activity. In order to replace BPA a number of bisphenol analogues have been designed. However, their activity profile is poorly described and little information exists about their endocrine disrupting potential and interactions with nuclear receptors. An understanding of such interaction may unravel mechanism of their molecular action and provide valuable inputs for risk assessment. BPA binds and activates peroxisome proliferator-activated receptors (PPARs) and retinoid X receptors (RXRs) which act as transcription factors and regulate genes involved in glucose, lipid, and cholesterol metabolism and adipogenesis. We studied binding efficiency of 18 bisphenol analogues and BPA with human PPARs and RXRs. Using Maestro Schrodinger 9.4, docking scores of bisphenols were compared with the known endogenous and exogenous ligands of hPPARs and hRXRs. BPA showed good binding efficiency. Several analogues also showed higher binding efficiency than BPA. BPPH which has high tendency to be absorbed in tissues showed the strongest binding with hPPARα, hPPARβ, hPPARγ and hRXRα whereas two of the most toxic bisphenols, BPM and BPAF showed strongest binding with hRXRβ and hRXRγ. Some of the bisphenol analogues showed a stronger binding affinity with PPAR and RXR compared to BPA implying that BPA substitutes may not be fully safe and chemico-biological interactions indicate their toxic potential. These results may also serve to plan further studies for determining safety profile of bisphenol analogues and be helpful in risk characterization.
Weafer, Jessica; Baggott, Matthew J; de Wit, Harriet
2013-12-01
Behavioral measures of impulsivity are widely used in substance abuse research, yet relatively little attention has been devoted to establishing their psychometric properties, especially their reliability over repeated administration. The current study examined the test-retest reliability of a battery of standardized behavioral impulsivity tasks, including measures of impulsive choice (i.e., delay discounting, probability discounting, and the Balloon Analogue Risk Task), impulsive action (i.e., the stop signal task, the go/no-go task, and commission errors on the continuous performance task), and inattention (i.e., attention lapses on a simple reaction time task and omission errors on the continuous performance task). Healthy adults (n = 128) performed the battery on two separate occasions. Reliability estimates for the individual tasks ranged from moderate to high, with Pearson correlations within the specific impulsivity domains as follows: impulsive choice (r range: .76-.89, ps < .001); impulsive action (r range: .65-.73, ps < .001); and inattention (r range: .38-.42, ps < .001). Additionally, the influence of day-to-day fluctuations in mood, as measured by the Profile of Mood States, was assessed in relation to variability in performance on each of the behavioral tasks. Change in performance on the delay discounting task was significantly associated with change in positive mood and arousal. No other behavioral measures were significantly associated with mood. In sum, the current analysis demonstrates that behavioral measures of impulsivity are reliable measures and thus can be confidently used to assess various facets of impulsivity as intermediate phenotypes for drug abuse.
Weafer, Jessica; Baggott, Matthew J.; de Wit, Harriet
2014-01-01
Behavioral measures of impulsivity are widely used in substance abuse research, yet relatively little attention has been devoted to establishing their psychometric properties, especially their reliability over repeated administration. The current study examined the test-retest reliability of a battery of standardized behavioral impulsivity tasks, including measures of impulsive choice (delay discounting, probability discounting, and the Balloon Analogue Risk Task), impulsive action (the stop signal task, the go/no-go task, and commission errors on the continuous performance task), and inattention (attention lapses on a simple reaction time task and omission errors on the continuous performance task). Healthy adults (n=128) performed the battery on two separate occasions. Reliability estimates for the individual tasks ranged from moderate to high, with Pearson correlations within the specific impulsivity domains as follows: impulsive choice (r = .76 - .89, ps < .001); impulsive action (r = .65 - .73, ps < .001); and inattention (r = .38-.42, ps < .001). Additionally, the influence of day-to-day fluctuations in mood as measured by the Profile of Mood States was assessed in relation to variability in performance on each of the behavioral tasks. Change in performance on the delay discounting task was significantly associated with change in positive mood and arousal. No other behavioral measures were significantly associated with mood. In sum, the current analysis demonstrates that behavioral measures of impulsivity are reliable measures and thus can be confidently used to assess various facets of impulsivity as intermediate phenotypes for drug abuse. PMID:24099351
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Qinghua, E-mail: qh-wu77@163.com; Liu, Zhuan, E-mail: liuchuan2015ck@163.com; Zhao, Xianlan, E-mail: zxl121292014@163.com
PurposeTo explore the efficacy and safety of prophylactic temporary balloon occlusion of the infrarenal abdominal aorta during caesarean for the management of patients with placenta praevia accreta.MethodsTwo hundred and sixty-eight cases of placenta praevia accreta from January 2012 to June 2015 were retrospectively reviewed. Group A included two hundred and thirty patients who underwent prophylactic temporary balloon occlusion of infrarenal abdominal aorta followed by caesarean section. Group B included thirty-eight patients who underwent caesarean without endovascular intervention. The parameters including operating room time, estimated blood loss, blood transfusion volume, PT (prothrombin time) during operation, days in the intensive care unit,more » and total hospital days were compared between the two groups.ResultsThe operating room time, estimated blood loss, PT, the incidence of hysterectomy, blood transfusion volume, postpartum haemorrhage, and days in intensive care unit were lower in group A than in group B, with statistical significance (P < 0.05). There was no significant difference in the Apgar scores of the neonates and the incidences of thrombosis in lower limbs between the two groups (P > 0.05). No patient in the group with prophylactic temporary balloon occlusion of the infrarenal abdominal aorta was performed hysterectomy, while three patients in group B were performed hysterectomy because of uncontrollable haemorrhage.ConclusionsThe results indicate that prophylactic temporary balloon occlusion of infrarenal abdominal aorta followed by caesarean section is safe and effective to control intraoperative blood loss and greatly decreases the risk of hysterectomy in patients with placenta praevia accreta.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ogami, Ryo, E-mail: ogami.r@mazda.co.jp; Nakahara, Toshinori; Hamasaki, Osamu
2011-10-15
Purpose: A rare complication of carotid artery stenting (CAS), prolonged reversible neurological symptoms with delayed cerebrospinal fluid (CSF) space enhancement on fluid attenuated inversion recovery (FLAIR) images, is associated with blood-brain barrier (BBB) disruption. We prospectively identified patients who showed CSF space enhancement on FLAIR images. Methods: Nineteen patients-5 acute-phase and 14 scheduled-underwent 21 CAS procedures. Balloon catheters were navigated across stenoses, angioplasty was performed using a neuroprotective balloon, and stents were placed with after dilation under distal balloon protection. CSF space hyperintensity or obscuration on FLAIR after versus before CAS indicated CSF space enhancement. Correlations with clinical factors weremore » examined. Results: CSF space was enhanced on FLAIR in 12 (57.1%) cases. Postprocedural CSF space enhancement was significantly related to age, stenosis rate, acute-stage procedure, and total occlusion time. All acute-stage CAS patients showed delayed enhancement. Only age was associated with delayed CSF space enhancement in scheduled CAS patients. Conclusions: Ischemic intolerance for severe carotid artery stenosis and temporary neuroprotective balloon occlusion, causing reperfusion injury, seem to be the main factors that underlie BBB disruption with delayed CSF space enhancement shortly after CAS, rather than sudden poststenting hemodynamic change. Our results suggest that factors related to hemodynamic instability or ischemic intolerance seem to be associated with post-CAS BBB vulnerability. Patients at risk for hemodynamic instability or with ischemic intolerance, which decrease BBB integrity, require careful management to prevent intracranial hemorrhagic and other post-CAS complications.« less
Cui, S H; Zhi, Y X; Zhang, K; Zhang, L D; Shen, L N; Gao, Y N
2016-09-25
Objective: To investigate the value of temporary balloon occlusion of the abdominal aorta in the treatment of complete placenta previa with placenta accreta. Methods: From January 2015 to February 2016, 24 cases of complete placenta previa with placenta accreta were treated with temporary balloon occlusion of the abdominal aorta(the study group)before cesarean, and 24 cases of complete placenta previa with placenta accreta did not receive balloon occlusion(the control group). The operation time, intraoperative blood loss, intraoperative blood transfusion volume, the perioperative hemoglobin level, the hysterectomy rate and the related complications were compared retrospectively.Also, the hospitalization time, the blood coagulation parameters after operation, including activated partial thromboplastin time(APTT), fibrinogen(FIB), D-Dimer and reperfusion injury parameters including creatine phosphokinase(CK), creatine phosphokinase isoenzyme(CK-MB), lactate dehydrogenase(LDH)and serum creatinine were compared between the 2 groups. Results: The blood loss[750 ml(400- 2 000 ml)vs 2 000 ml(1 500- 2 375 ml); Z =-3.214, P =0.001]and blood transfusion volume[200 ml(0-800 ml)vs 800 ml(0-1 200 ml); Z =- 2.173, P =0.030]in the study group were lower than in the control group. The hemoglobin difference between before and after operation in the study group was lower than the control group[(12.8±13.4)g/L vs(22.9±20.1)g/L; t =-2.041, P =0.047]. In the study group, there were still bleeding in 13 cases after releasing the balloon, 5 of them received uterine artery embolization, 5 cases received uterine artery ligation, and 3 cases received uterine packing. One case had venous thrombosis in the right lower limb. Two cases(8%,2/24)in the control group had hysterectomy, while none in the study group, there was no statistical significance( P = 0.489). Conclusions: Temporary balloon occlusion of the abdominal aorta can effectively reduce blood loss and blood transfusion in the treatment of complete placenta previa with placenta accreta, but there is still the risk of continuing bleeding after releasing the balloon. Other methods of hemostasis might be needed.
Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter.
Kim, Jin Woo; Kim, Byung Moon; Park, Keun Young; Kim, Dong Joon; Kim, Dong Ik
2016-05-01
Utilization of a dual-lumen balloon may improve Onyx penetration into isolated dural arteriovenous fistulas (i-DAVFs). To compare the results of Onyx embolization using a dual-lumen balloon with those using a non-balloon catheter for i-DAVFs. Twenty-nine patients underwent Onyx embolization for i-DAVFs using a non-balloon (n = 14) or a dual-lumen balloon catheter (n = 15). Since its introduction, a dual-lumen balloon catheter has been preferred. We compared the dual-lumen balloon group with the non-balloon catheter group regarding angiographic outcome, treatment-related complications, total procedural time, Onyx injection time, and the number of feeders requiring embolization. The dual-lumen balloon group showed complete occlusion of i-DAVFs in 13 and near-complete in 2 patients, while the non-balloon group showed complete occlusion in 5, near-complete in 5, and incomplete in 4 patients (P < .05). Treatment-related complications occurred in 2 patients: 1 in the non-balloon group and 1 in the dual-lumen balloon group. The mean total procedural time was 62 ± 32 minutes in the dual-lumen balloon and 171 ± 88 minutes in the non-balloon group (P < .05). The mean Onyx injection time was 10 ± 6 minutes in the dual-lumen balloon and 49 ± 32 minutes in the non-balloon group (P < .05). The median number of feeders requiring embolization was 1 (range, 1-3) in the dual-lumen balloon and 2 (range, 1-4) in the non-balloon group (P < .05). Utilization of a dual-lumen balloon catheter for Onyx embolization of i-DAVF seemed to significantly increase the immediate complete occlusion rate and decrease total procedural time, Onyx injection time, and number of feeders requiring embolization.
Reward-Seeking Behavior in Human Narcolepsy
Dimitrova, Alexandra; Fronczek, Rolf; Van der Ploeg, Janneke; Scammell, Thomas; Gautam, Shiva; Pascual-Leone, Alvaro; Lammers, Gert Jan
2011-01-01
Study Objectives: The hypocretin system enhances signaling in the mesolimbic pathways regulating reward processing and addiction. Because individuals with narcolepsy with cataplexy have low hypocretin levels, we hypothesized that they may be less prone to risk- and reward-seeking behaviors, including substance abuse. Design: Endpoints were performance on an array of psychometric tests (including the Eysenck Impulsiveness Scale, the Zuckerman Sensation Seeking Scale, the Gormally Binge Eating Scale, and the Beck Depression and Anxiety Inventory) and on the Balloon Analogue Risk Task (BART). Setting: Tertiary narcolepsy referral centers in Leiden (The Netherlands) and Boston (USA). Patients: Subjects with narcolepsy with cataplexy (n = 30), narcolepsy without cataplexy (n = 15), and controls (n = 32) matched for age, sex, and smoking behavior. Interventions: None. Measurements and Results: There was no difference in risk-taking behavior between narcolepsy with or without cataplexy and the control group, as measured using the BART and the array of questionnaires. However, subjects in the narcolepsy with cataplexy group had significantly higher scores on the Eysenck Impulsiveness Scale (p < 0.05), with 10.0% categorized as impulsive, compared to 6.7% of the narcolepsy without cataplexy group and none of the controls. Narcoleptics with cataplexy also scored significantly higher than controls on the Binge Eating Scale (p < 0.05), with moderate or severe binge eating in 23%. On the depression and anxiety scales, all narcolepsy patients, especially those with cataplexy, scored significantly higher than controls. Conclusions: We found that narcoleptics with or without cataplexy generally have normal risk-taking behavior, but narcoleptics with cataplexy were more impulsive and more prone to binge eating than patients without cataplexy and controls. Our findings shed new light on the relation between sleepiness and impulsiveness. Furthermore, rates of depression and anxiety were higher in all narcoleptic subjects. However, using the current methods, no evidence could be found to support the hypothesis that hypocretin deficiency would affect reward-processing in humans. Citation: Dimitrova A; Fronczek R; Van der Ploeg J; Scammell T; Gautam S; Pascual-Leone A; Lammers GJ. Reward-seeking behavior in human narcolepsy. J Clin Sleep Med 2011;7(3):293-300. PMID:21677900
Telescope Systems for Balloon-Borne Research
NASA Technical Reports Server (NTRS)
Swift, C. (Editor); Witteborn, F. C. (Editor); Shipley, A. (Editor)
1974-01-01
The proceedings of a conference on the use of balloons for scientific research are presented. The subjects discussed include the following: (1) astronomical observations with balloon-borne telescopes, (2) orientable, stabilized balloon-borne gondola for around-the-world flights, (3) ultraviolet stellar spectrophotometry from a balloon platform, (4) infrared telescope for balloon-borne infrared astronomy, and (5) stabilization, pointing, and command control of balloon-borne telescopes.
Biondi-Zoccai, Giuseppe; Sheiban, Imad; De Servi, Stefano; Tamburino, Corrado; Sangiorgi, Giuseppe; Romagnoli, Enrico
2014-11-01
Final kissing-balloon inflation is often recommended for percutaneous coronary intervention (PCI) of bifurcation lesions. However, randomized trials focusing on kissing inflation have not confirmed its beneficial impact. We compared outcomes of kissing inflation for PCI of bifurcation lesions, explicitly stratifying results according to stenting strategy. Patients undergoing bifurcation PCI were retrospectively enrolled. Subjects receiving final kissing inflation were compared with those not undergoing kissing inflation, after stratification for a single-stent technique. The primary end point was the long-term rate of major adverse cardiac events (MACE, i.e., death, myocardial infarction, or target lesion revascularization (TLR)). A total of 4314 patients were included: 1176 (27.3 %) treated with a single stent and kissing inflation, 1637 (37.9 %) with a single stent but no kissing, 1072 (24.8 %) with two stents and kissing, and 429 (9.9 %) with two stents but no kissing. At unadjusted analyses kissing was associated with fewer short-term MACE and deaths in the two-stent group, and with fewer long-term MACE, cardiac deaths, and side-branch TLR in the two-stent group (all P < 0.05). Conversely, kissing appeared detrimental after single stenting. However, after multivariable analyses, kissing no longer significantly affected the risk of adverse events, with the exception of the risk of side-branch TLR, which was lower in those receiving two stents and final kissing inflation (hazard ratio = 0.52, 95 % confidence interval 0.30–0.90, P = 0.020). Kissing inflation can be avoided in bifurcation lesions uneventfully treated with single-stent PCI. However, final kissing-balloon inflation appears beneficial in reducing the risk of side-branch repeat revascularization after using a two-stent strategy.
ERIC Educational Resources Information Center
Balloon Council, Washington, DC.
This document provides background information on balloons including: (1) the history of balloons; (2) balloon manufacturing; (3) biodegradability; (4) the fate of latex balloons; and (5) the effect of balloons on the rainforest and sea mammals. Also included as part of this instructional kit are four fun experiments that allow students to…
NASA Astrophysics Data System (ADS)
Saito, Yoshitaka; Nakashino, Kyoichi; Akita, Daisuke; Matsushima, Kiyoho; Shimadu, Shigeyuki; Goto, Ken; Hashimoto, Hiroyuki; Matsuo, Takuma
2016-07-01
A light super-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m^{3} balloon. Beginning from a demonstration test of the net-balloon with a 10 m^{3} balloon in 2010, we have been polished the net-balloon through ground inflation tests and flight tests, including a flight test of a 3,000 m ^{3} balloon in the tandem balloon configuration with a 15,000 m^{3} zero-pressure balloon in 2012, and a flight test of a 10 m^{3} balloon in the tandem balloon configuration with a 2 kg rubber balloon in 2013, as reported in the last COSPAR. In 2014, we developed a 5,000 m^{3} balloon and performed a ground inflation test to find that the balloon burst from a lip panel for termination with a differential pressure of 425 Pa. It was due to a stress concentration at the edge of a thick tape attached along the termination mechanism. In 2015, we modified the balloon by adding tapes on the lip panel to avoid the stress concentration, and also shorten the net length to leave some margin of the film and performed a ground inflation test again to find the balloon showed asymmetrical deployment and burst from the edge of the net with a differential pressure of 348 Pa. We consider it is due to the margin of the film along the circumferential direction, and proposed a gore shape which circumference length is kept as determined by the pumpkin shape of the balloon but setting meridian length longer than that. We developed a 10 m^{3} balloon with the gore design to find that the balloon deployed symmetrically and showed the burst pressure of 10,000 Pa. In 2016, we are going to develop a 2,000 m^{3} balloon with the gore design and perform its ground inflation test. In this paper, we are going to report its result with the sequence of the development.
NASA Astrophysics Data System (ADS)
Felix, C. V.; Gini, A.
When talking about human space exploration, Mars missions are always present. It is clear that sooner or later, humanity will take this adventure. Arguably the most important aspect to consider for the success of such an endeavour is the human element. The safety of the crew throughout a Martian mission is a top priority for all space agencies. Therefore, such a mission should not take place until all the risks have been fully understood and mitigated. A mission to Mars presents unique human and technological challenges in terms of isolation, confinement, autonomy, reliance on mission control, communication delays and adaptation to different gravity levels. Analogue environments provide the safest way to simulate these conditions, mitigate the risks and evaluate the effects of long-term space travel on the crew. Martian Feeling is one of nine analogue studies, from the Mars Analogue Path (MAP) report [1], proposed by the TP Analogue group of ISU Masters class 2010. It is an integrated analogue study which simulates the psychological, physiological and operational conditions that an international, six-person, mixed gender crew would experience on a mission to Mars. Set both onboard the International Space Station (ISS) and on Earth, the Martian Feeling study will perform a ``dress rehearsal'' of a mission to Mars. The study proposes to test both human performance and operational procedures in a cost-effective manner. Since Low Earth Orbit (LEO) is more accessible than other space-based locations, an analogue studies in LEO would provide the required level of realism to a simulated transit mission to Mars. The sustained presence of microgravity and other elements of true spaceflight are features of LEO that are neither currently feasible nor possible to study in terrestrial analogue sites. International collaboration, economics, legal and ethical issues were considered when the study was proposed. As an example of international collaboration, the ISS would demonstrate an effective model for an international effort to send humans to Mars. The proposed starting date is the year 2017, before the planned retirement of the ISS, which is currently scheduled for 2020.
Bramlage, Peter; Strauch, Justus; Schröfel, Holger
2014-11-18
In patients with severe calcific aortic stenosis, balloon aortic valvuloplasty (BAV) is routinely performed in order to pre-dilate the stenosed aortic valve prior to transcatheter aortic valve implantation (TAVI). Although pre-dilation is considered to be essential for the preparation of the valve landing zone, there is no clear evidence to support its clinical value. In contrast, BAV has been suggested to be linked to several complications. Notably, while preliminary evidence has supported the feasibility and safety of TAVI without pre-dilation, larger studies directly comparing the benefit/risk profile of TAVI in the presence and absence of pre-dilation are required. Therefore, a prospective, two-armed, multicenter registry (EASE-IT) was designed to obtain essential data concerning procedural success rates, adverse events, and mortality in a large cohort of patients undergoing transapical (TA)-TAVI using the Edwards SAPIEN 3 balloon expandable heart valves with and without pre-ballooning. Data provided by EASE-IT will be used to assess the relevance of BAV during the TAVI procedure and to investigate associations between patient characteristics and outcomes. Therefore, results obtained from the EASE-IT registry could contribute to reduced rates of TAVI-associated morbidity and mortality in patients with severe, calcific aortic stenosis. ClinicalTrials.gov Identifier: NCT02127580.
Properties of nylon 12 balloons after thermal and liquid carbon dioxide treatments.
Ro, Andrew J; Davé, Vipul
2013-03-01
Critical design attributes of angioplasty balloons include the following: tear resistance, high burst pressures, controlled compliance, and high fatigue. Balloons must have tear resistance and high burst pressures because a calcified stenosis can be hard and nominal pressures of up to 16 atm can be used to expand the balloon. The inflated balloon diameter must be a function of the inflation pressure, thus compliance is predictable and controlled. Reliable compliance is necessary to prevent damage to vessel walls, which may be caused by over-inflation. Balloons are often inflated multiple times in a clinical setting and they must be highly resistant to fatigue. These design attributes are dependent on the mechanical properties and polymer morphology of the balloon. The effects of residual stresses on shrinkage, crystallite orientation, balloon compliance, and mechanical properties were studied for angioplasty nylon 12 balloons. Residual stresses of these balloons were relieved by oven heat treatment and liquid CO2 exposure. Residual stresses were measured by quantifying shrinkage at 80 °C of excised balloon samples using a dynamic mechanical analyzer. Shrinkage was lower after oven heat treatment and liquid CO2 exposure compared to the as-received balloons, in the axial and radial directions. As-received, oven heat treated, and liquid CO2-exposed balloon samples exhibited similar thermal properties (T(g), T(m), X(t)). Crystallite orientation was not observed in the balloon cylindrical body using X-ray scattering and polarized light microscopy, which may be due to balloon fabrication conditions. Significant differences were not observed between the stress-strain curves, balloon compliance, and average burst pressures of the as-received, oven heat treated, and liquid CO2-exposed balloons. Copyright © 2012 Elsevier B.V. All rights reserved.
A stress index model for ascending balloons
NASA Technical Reports Server (NTRS)
Smith, I. S.
1986-01-01
Attention is given to the development on the part of NASA of a simplified stress 'index' model to establish the relative stress magnitudes along a balloon's gore position as a function of altitude. Application of this model to several hundred balloon flights showed a good correlation between balloon failure rate and stress 'index' level. This model can be used during the balloon design process to lower the levels of stress in the balloon. By increasing the wall thickness of the balloon, adding caps, lengthening caps, or using external caps, lower stress can be accomplished. As a result, in January 1985, the NASA Balloon Program established a stress index specification to limit the design and flight stresses for NASA balloons.
McElhinney, Doff B; Lacro, Ronald V; Gauvreau, Kimberlee; O'Brien, Cheryl M; Yaroglu Kazanci, Selcen; Vogel, Melanie; Emani, Sitaram; Brown, David W
2012-09-01
Dilation of the ascending aorta (AA) is common in patients with a bicuspid aortic valve. The natural history of the aortic root and AA and the risk factors for dilation have not been characterized in patients with congenital aortic stenosis (AS) treated with balloon valvuloplasty during childhood. The present study was performed to determine the prevalence of aortic dilation in patients with congenital AS before and up to 20 years after balloon valvuloplasty performed during childhood. In patients who underwent balloon valvuloplasty for AS at age ≤ 18 years from 1984 to 2005, the aortic diameter measurements before intervention and at 5-year intervals afterward were recorded and the Z scores calculated. Among 156 patients (median age 1.5 years at valvuloplasty), the AA Z scores were significantly larger than normal before intervention (median Z score 1.5) and at all follow-up points (all p <0.001). Using mixed modeling, with time as a categorical variable (before intervention, 5-year window, 10-year window, and so forth), the mean AA Z score was greater at all postvalvuloplasty points than before the intervention, with mean Z score increases of 1.20 at 5 years and 2.11 at 20 years (p <0.001). Moderate or greater aortic regurgitation early after valvuloplasty was associated with greater AA Z scores than mild or less aortic regurgitation, with a progressive difference over time. More significant residual AS after valvuloplasty was associated with lower AA Z scores over time. In conclusion, AA dilation is common in children with congenital AS and continues to progress over many years after balloon valvuloplasty. Copyright © 2012 Elsevier Inc. All rights reserved.
Kumar, Nitin; Bazerbachi, Fateh; Rustagi, Tarun; McCarty, Thomas R; Thompson, Christopher C; Galvao Neto, Manoel P; Zundel, Natan; Wilson, Erik B; Gostout, Christopher J; Abu Dayyeh, Barham K
2017-09-01
The Orbera intragastric balloon (IGB) has been approved by the US Food and Drug Administration for use in patients with a body mass index (BMI) between 30 and 40 kg/m 2 and is in wide use worldwide as a primary and bridge obesity management tool. The balloon filling volume (BFV) ranges between 400 and 700 mL of saline. Our objective was to determine whether there is an association between BFV and clinically relevant endpoints, namely weight loss outcomes, balloon tolerability, and adverse events. A systematic review of studies investigating the use of the Orbera IGB system for obesity treatment was performed. Data was examined using random effects modelling and meta-regression analyses. Forty-four studies (n = 5549 patients) reported BFV and % total body weight loss (TBWL) at 6 months. Pooled %TBWL at 6 months was 13.2% [95% CI 12.3-14.0]. A funnel plot demonstrated a low risk of publication bias. Meta-regression showed no statistically significant association between filling volume and %TBWL at 6 months (p = 0.268). Higher BFV was associated with lower rates of esophagitis (slope = -0.008, p < 0.001) and prosthesis migration (slope = -0.015, p < 0.001). There was no association between BFV and early removal (p = 0.1), gastroesophageal reflux symptom (p = 0.64), or ulcer rates (p = 0.09). No association was observed between Orbera IGB filling volume and weight loss outcomes. Higher volumes appear to be associated with lower migration and esophagitis rates; thus, a balloon filling volume of 600-650 mL is recommended.
Zanetti, Miriam Raquel Diniz; Petricelli, Carla Dellabarba; Alexandre, Sandra Maria; Paschoal, Aline; Araujo Júnior, Edward; Nakamura, Mary Uchiyama
2016-04-01
Several risk factors are involved in perineal lacerations during vaginal delivery. However, little is known about the influence of perineal distensibility as a protective factor. The aim here was to determine a cutoff value for pelvic floor distensibility measured using the Epi-no balloon, which could be used as a predictive factor for perineal integrity in vaginal delivery. Prospective observational single cohort study conducted in a maternity hospital. A convenience sample of 227 consecutive at-term parturients was used. All women had a single fetus in the vertex presentation, with up to 9.0 cm of dilation. The maximum dilation of the Epi-no balloon was measured using a tape measure after it had been inflated inside the vagina up to the parturients' maximum tolerance. The receiver operating characteristic (ROC) curve was used to obtain the Epi-no circumference measurement with best sensitivity and specificity. Among the 161 patients who were included in the study, 50.9% underwent episiotomy, 21.8% presented lacerations and 27.3% retained an intact perineum. Age > 25.9 years; number of pregnancies > 3.4; number of deliveries > 2.2 and circumference measured by Epi-no > 21.4 cm were all directly correlated with an intact perineum. Circumference measurements using the Epi-no balloon that were greater than 20.8 cm showed sensitivity and specificity of 70.5% and 66.7% (area under curve = 0.713), respectively, as a predictive factor for an intact perineum in vaginal delivery. Circumferences greater than 20.8 cm achieved using the Epi-no balloon are a predictive factor for perineal integrity in parturients.
Soyama, Hiroaki; Miyamoto, Morikazu; Sasa, Hidenori; Ishibashi, Hiroki; Yoshida, Masashi; Nakatsuka, Masaya; Takano, Masashi; Furuya, Kenichi
2017-09-01
To evaluate the effectiveness of routine rapid insertion of a Bakri balloon during cesarean section for placenta previa based on a retrospective control study. Women with singleton pregnancies who underwent cesarean section for placenta previa at our institution between 2003 and 2016 were enrolled. Between 2015 and 2016, women who routinely underwent balloon tamponade during cesarean section were defined as the balloon group. Between 2003 and 2014, women who underwent no hemostatic procedures except balloon tamponade were defined as the non-balloon group. The clinical outcomes of the two groups were retrospectively analyzed. Of the 266 women with placenta previa, 50 were in the balloon group and 216 were in the non-balloon group. The bleeding amounts were significantly smaller in the balloon group than in the non-balloon group: intraoperative bleeding (991 vs. 1250 g, p < 0.01), postoperative bleeding (62 vs. 150 g, p < 0.01), and total bleeding (1066 vs. 1451 g, p < 0.01). Furthermore, the mean surgical duration was shorter in the balloon group than the non-balloon group (30 vs. 50 min, p < 0.01). In the balloon group, five patients suffered from increasing hemorrhage due to prolapse of the balloon from the uterus after the operation, but the hemorrhage was controlled by balloon re-insertion without additional hemostatic procedures. This study demonstrated that the routine rapid insertion of Bakri balloon tamponade during cesarean section significantly decreased intra- and postoperative hemorrhage and shortened the surgical duration in women with placenta previa.
21 CFR 870.1350 - Catheter balloon repair kit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...
21 CFR 870.1350 - Catheter balloon repair kit.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...
21 CFR 870.1350 - Catheter balloon repair kit.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...
Status of the NASA Balloon Program
NASA Astrophysics Data System (ADS)
Needleman, H. C.; Nock, R. S.; Bawcom, D. W.
1993-02-01
In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.
Controlled weather balloon ascents and descents for atmospheric research and climate monitoring
Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F.; Hall, Emrys G.; Jordan, Allen F.
2017-01-01
In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth’s surface to about 35 km (3–5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent. PMID:29263765
Controlled weather balloon ascents and descents for atmospheric research and climate monitoring.
Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F; Hall, Emrys G; Jordan, Allen F
2016-01-01
In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth's surface to about 35 km (3-5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent.
Prediction of breast cancer risk with volatile biomarkers in breath.
Phillips, Michael; Cataneo, Renee N; Cruz-Ramos, Jose Alfonso; Huston, Jan; Ornelas, Omar; Pappas, Nadine; Pathak, Sonali
2018-03-23
Human breath contains volatile organic compounds (VOCs) that are biomarkers of breast cancer. We investigated the positive and negative predictive values (PPV and NPV) of breath VOC biomarkers as indicators of breast cancer risk. We employed ultra-clean breath collection balloons to collect breath samples from 54 women with biopsy-proven breast cancer and 124 cancer-free controls. Breath VOCs were analyzed with gas chromatography (GC) combined with either mass spectrometry (GC MS) or surface acoustic wave detection (GC SAW). Chromatograms were randomly assigned to a training set or a validation set. Monte Carlo analysis identified significant breath VOC biomarkers of breast cancer in the training set, and these biomarkers were incorporated into a multivariate algorithm to predict disease in the validation set. In the unsplit dataset, the predictive algorithms generated discriminant function (DF) values that varied with sensitivity, specificity, PPV and NPV. Using GC MS, test accuracy = 90% (area under curve of receiver operating characteristic in unsplit dataset) and cross-validated accuracy = 77%. Using GC SAW, test accuracy = 86% and cross-validated accuracy = 74%. With both assays, a low DF value was associated with a low risk of breast cancer (NPV > 99.9%). A high DF value was associated with a high risk of breast cancer and PPV rising to 100%. Analysis of breath VOC samples collected with ultra-clean balloons detected biomarkers that accurately predicted risk of breast cancer.
Miceli, Antonio; Duggan, Simon M J; Capoun, Radek; Romeo, Francesco; Caputo, Massimo; Angelini, Gianni D
2010-08-01
There is no accepted consensus on the definition of high-risk patients who may benefit from the use of intraaortic balloon pump (IABP) in coronary artery bypass grafting (CABG). The aim of this study was to develop a risk model to identify high-risk patients and predict the need for IABP insertion during CABG. From April 1996 to December 2006, 8,872 consecutive patients underwent isolated CABG; of these 182 patients (2.1%) received intraoperative or postoperative IABP. The scoring risk model was developed in 4,575 patients (derivation dataset) and validated on the remaining patients (validation dataset). Predictive accuracy was evaluated by the area under the receiver operating characteristic curve. Mortality was 1% in the entire cohort and 18.7% (22 patients) in the group which received IABP. Multivariable analysis showed that age greater than 70 years, moderate and poor left ventricular dysfunction, previous cardiac surgery, emergency operation, left main disease, Canadian Cardiovascular Society 3-4 class, and recent myocardial infarction were independent risk factors for the need of IABP insertion. Three risk groups were identified. The observed probability of receiving IABP and mortality in the validation dataset was 36.4% and 10% in the high-risk group (score >14), 10.9% and 2.8% in the medium-risk group (score 7 to 13), and 1.7% and 0.7% in the low-risk group (score 0 to 6). This simple clinical risk model based on preoperative clinical data can be used to identify high-risk patients who may benefit from elective insertion of IABP during CABG. Copyright 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Evolution of scientific ballooning and its impact on astrophysics research
NASA Astrophysics Data System (ADS)
Jones, William Vernon
2014-05-01
As we celebrate the centennial year of the discovery of cosmic rays on a manned balloon, it seems appropriate to reflect on the evolution of ballooning and its scientific impact. Balloons have been used for scientific research since they were invented in France more than 200 years ago. Ballooning was revolutionized in 1950 with the introduction of the so-called natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for more than a half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing the next generation super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. The Astro2010 Decadal Survey report supports super-pressure balloon development and the giant step forward it offers with ultra-long-duration balloon (ULDB) flights at constant altitudes for about 100 days.
Investigation of hot air balloon fatalities.
McConnell, T S; Smialek, J E; Capron, R G
1985-04-01
The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.
NASA Astrophysics Data System (ADS)
Buduru, Suneel Kumar
2016-07-01
The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) is a unique center of expertise working throughout the year to design, fabricate and launch scientific balloons mainly for space astronomy, atmospheric science and engineering experiments. Recently TIFR-BF extended its support to new user scientists for conducting balloon launches for biological and middle atmospheric sciences. For the first time two balloon launches conducted for sending live lab rats to upper stratosphere and provided launch support for different balloon campaigns such as Tropical Tropopause Dynamics (TTD) to study water vapour content in upper tropospheric and lower stratospheric regions over Hyderabad and the other balloon campaign to study the Asian Tropopause Aerosol Layer (BATAL) during the Indian summer monsoon season. BATAL is the first campaign to conduct balloon launches during active (South-West) monsoon season using zero pressure balloons of different volumes. TIFR-BF also provided zero pressure and sounding balloon support to various research institutes and organizations in India and for several international space projects. In this paper, we present details on our increased capability of balloon fabrication for carrying heavier payloads, development of high strength balloon load tapes and recent developments of flight control and safety systems. A summary of the various flights conducted in two years will be presented along with the future ballooning plans.
Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R
2016-12-21
To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients.
Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R
2016-01-01
AIM To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). METHODS VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. RESULTS Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. CONCLUSION Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients. PMID:28058017
Clinical experience with the Monorail balloon catheter for coronary angioplasty.
Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W
1988-01-01
The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.
Use of monorail PTCA balloon catheter for local drug delivery.
Trehan, Vijay; Nair, Girish M; Gupta, Mohit D
2007-01-01
We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.
Hot-Air Ballooning in Physics Teaching.
ERIC Educational Resources Information Center
Haugland, Ole Anton
1991-01-01
Describes the modern hot-air balloon and the physics of ballooning. Proposes that students construct their own hot-air balloon and presents an experiment calculating the time needed for a balloon to rise to the ceiling of a gymnasium. (MDH)
Mild, Kjell Hansson; Hardell, Lennart; Carlberg, Michael
2007-01-01
Here we present the pooled analysis of 2 case-control studies on the association of brain tumours with mobile phone use. Use of analogue cellular phones increased the risk for acoustic neuroma by 5%, 95% confidence interval (CI) = 2-9% per 100 hrs of use. The risk increased for astrocytoma grade III-IV with latency period with highest estimates using >10-year time period from first use of these phone types. The risk increased per one year of use of analogue phones by 10%, 95% CI = 6-14%, digital phones by 11%, 95% CI = 6-16%, and cordless phones by 8%, 95% CI = 5-12%. For all studied phone types OR for brain tumours, mainly acoustic neuroma and malignant brain tumours, increased with latency period, especially for astrocytoma grade III-IV.
Air Force Cambridge Research Laboratories balloon operations
NASA Technical Reports Server (NTRS)
Danaher, T. J.
1974-01-01
The establishment and functions of the AFCRL balloon operations facility are discussed. The types of research work conducted by the facility are defined. The facilities which support the balloon programs are described. The free balloon and tethered balloon capabilities are analyzed.
[Iliac artery occlusion balloons for suspected placenta accreta during cesarean section].
Burgos Frías, N; Gredilla, E; Guasch, E; Gilsanz, F
2014-02-01
Massive obstetric hemorrhage still remains a major cause of maternal mortality and morbidity. The risk factors associated with this pathology must be identified in order to schedule the appropriate delivery with the necessary resources. A case is presented of an iliac artery occlusion with intravascular balloons for suspected placenta accreta during cesarean section. The perioperative treatment, as well as an analysis of the treatment options is described, along with their advantages and disadvantages, from the use of postpartum hemorrhage protocols, blood transfusion and procoagulant factors, and other maneuvers to control bleeding, until the hysterectomy. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.
Development of a Super-Pressure Balloon with an Improved Design
NASA Astrophysics Data System (ADS)
Izutsu, Naoki; Akita, Daisuke; Fuke, Hideyuki; Iijima, Issei; Kato, Yoichi; Kawada, Jiro; Matsushima, Kiyoho; Matsuzaka, Yukihiko; Mizuta, Eiichi; Nakada, Takashi; Nonaka, Naoki; Saito, Yoshitaka; Takada, Atsushi; Tamura, Keisuke; Yamada, Kazuhiko; Yoshida, Tetsuya
A zero-pressure balloon used for scientific observation in the stratosphere has an unmanageable limitation that its floating altitude decreases during a nighttime because of temperature drop of the lifting gas. Since a super-pressure balloon may not change its volume, the lifetime can extend very long. We had introduced so called the ‘lobed-pumpkin’ type of super-pressure balloon that can realize a full-scale long-duration balloon and it will be in practical use in the very near future. As for larger super-pressure balloons, however, we still have some potential difficulties to be resolved. We here propose a new design suitable for a larger super-pressure balloon, which is roughly ‘lobed pumpkin with lobed cylinder’ and can adapt a single design for balloons of a wide range of volumes. Indoor inflation tests were successfully carried out with balloons designed and made by the method. It has been shown that the limit of the resisting pressure differential for a new designed balloon is same as that of a normal lobed-pumpkin balloon.
Rai, Balwant; Kaur, Jasdeep
2012-11-01
Knowing the risks, costs, and complexities associated with human missions to Mars, analogue research can be a great (low-risk) tool for exploring the challenges associated with the preparation for living, operating, and undertaking research in interplanetary missions. Short-duration analogue studies, such as those being accomplished at the Mars Desert Research Station (MDRS), offer the chance to study mission operations and human factors in a simulated environment, and therefore contribute to exploration of the Moon and Mars in planned future missions. This article is based upon previously published articles, abstracts, and presentations by a series of independent authors, human factor studies performed on mars analogue station by Crew 100B. The MDRS Crew 100B performed studies over 15 days providing a unique insight into human factor issues in simulated short-duration Mars mission. In this study, 15 human factors were evaluated and analyzed by subjective and objective means, and from the summary of results it was concluded that optimum health of an individual and the crew as a whole is a necessity in order to encourage and maintain high performance and the satisfaction of project goals.
Rai, Balwant; Kaur, Jasdeep
2012-01-01
Knowing the risks, costs, and complexities associated with human missions to Mars, analogue research can be a great (low-risk) tool for exploring the challenges associated with the preparation for living, operating, and undertaking research in interplanetary missions. Short-duration analogue studies, such as those being accomplished at the Mars Desert Research Station (MDRS), offer the chance to study mission operations and human factors in a simulated environment, and therefore contribute to exploration of the Moon and Mars in planned future missions. This article is based upon previously published articles, abstracts, and presentations by a series of independent authors, human factor studies performed on mars analogue station by Crew 100B. The MDRS Crew 100B performed studies over 15 days providing a unique insight into human factor issues in simulated short-duration Mars mission. In this study, 15 human factors were evaluated and analyzed by subjective and objective means, and from the summary of results it was concluded that optimum health of an individual and the crew as a whole is a necessity in order to encourage and maintain high performance and the satisfaction of project goals. PMID:23181225
Development of a 5,000 m(3) super-pressure balloon with a diamond-shaped net
NASA Astrophysics Data System (ADS)
Saito, Yoshitaka; Tanaka, Shigeki; Nakashino, Kyoichi; Matsushima, Kiyoho; Goto, Ken; Furuta, Ryosuke; Domoto, Kodai; Akita, Daisuke; Hashimoto, Hiroyuki
A light super-pressure balloon of which weight will be comparable to the weight of the zero-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m(3) balloon. A flight test of a 3,000 m(3) balloon in the tandem balloon configuration with a 15,000 m(3) zero-pressure balloon was performed in 2012. Although a small gas leak occurred in the super-pressure balloon at the differential pressure of 400 to 500 Pa, the differential pressure reached the highest value of 814 Pa and kept positive through the level flight lasting for 25 minutes due to its slow leakage. To avoid a possible stress concentration to films at the polar area, a new design setting the meridian length of the balloon gore film equal to the length of the net was adopted. A 3-m balloon with the design was developed and its capacity to resist pressure at room temperature and at -30 (°) C was checked through the ground inflation tests. In 2013, a balloon of the same model was launched in the tandem balloon configuration with 2 kg rubber balloons. It was confirmed that the balloon could withstand the maximum differential pressure of 6,280 Pa, could withstand the differential pressure of 5,600 Pa for 2 hours, and there was a small gas leak through a hole with an area of 0.4 mm(2) which was also found in the ground leakage test. These results indicated that the improvement was adequate and there was no problem for the super-pressure balloon to fly in the environment of the stratosphere except for the problem of the small gas leak. In 2014, a flight test of a 5,000 m(3) balloon will be performed. In this paper, after reviewing the method to cover a balloon with a diamond-shaped net, the current status of the development will be reported.
Ovulation, In Vivo Emotion Regulation Problems, and Sexual Risk Recognition Deficits
ERIC Educational Resources Information Center
Walsh, Kate; DiLillo, David
2013-01-01
Objective: To examine associations between menstrual cycle phase, negative mood, sexual risk recognition deficits (assessed via an analogue risk vignette), and in vivo emotion dysregulation. Participants: Participants were 714 college women recruited between February 2007 and December 2009. Methods: Participants were randomly assigned to a…
Flight Qualification of the NASA's Super Pressure Balloon
NASA Astrophysics Data System (ADS)
Cathey, Henry; Said, Magdi; Fairbrother, Debora
Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test flight by successfully demonstrated balloon vehicle performance, obtained a large amount of videos, measured balloon differential pressure, obtained temperature and altitude data, assessed structure strength through pressurization, and demonstrated the balloon vehicles altitude stability. This flight was the first of several to qualify this design for the science community. Results of the most recent flights will be presented. Some of the related material characterization testing which is vital to the balloon design development for the balloon will also be presented. Additionally, this paper will provide a current overview of the development and qualification approach pursued for the NASA’s Super Pressure Balloon. Future plans and goals of future test flights will also be presented. This will include the projected balloon volumes, payload capabilities, test flight locations, and proposed flight schedule.
Making sense of endovascular therapies for femoropopliteal disease.
Altin, S Elissa; Abbott, J Dawn
2018-06-01
The femoropoliteal segment is a common target for endovascular intervention and the unique biomechanical forces on the arteries increase the risk of restenosis This large meta-analysis supports drug coated balloons as the initial endovascular strategy due to lower risk of target lesion revascularization compared to other modalities Whether there are subgroups of patients or lesion types that benefit from an alternative revascularization approach is unclear and warrants investigation. © 2018 Wiley Periodicals, Inc.
Status of the NASA Balloon Program
NASA Technical Reports Server (NTRS)
Needleman, H. C.; Nock, R. S.; Bawcom, D. W.
1993-01-01
The NASA Balloon Program (BP) is examined in an overview of design philosophy, R&D activities, flight testing, and the development of a long-duration balloon for Antarctic use. The Balloon Recovery Program was developed to qualify the use of existing films and to design improved materials and seals. Balloon flights are described for studying the supernova SN1987a, and systems were developed to enhance balloon campaigns including mobile launch vehicles and tracking/data-acquisition systems. The technical approach to long-duration ballooning is reviewed which allows the use of payloads of up to 1350 kg for two to three weeks. The BP is responsible for the development of several candidate polyethylene balloon films as well as design/performance standards for candidate balloons. Specific progress is noted in reliability and in R&D with respect to optimization of structural design, resin blending, and extrusion.
GHOST balloons around Antarctica
NASA Technical Reports Server (NTRS)
Stearns, Charles R.
1988-01-01
The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.
Concepts for autonomous flight control for a balloon on Mars
NASA Technical Reports Server (NTRS)
Heinsheimer, Thomas F.; Friend, Robyn C.; Siegel, Neil G.
1988-01-01
Balloons operating as airborne rovers have been suggested as ideal candidates for early exploration of the Martian surface. An international study team composed of scientists from the U.S.S.R., France, and the U.S.A. is planning the launching in 1994 of a balloon system to fly on Mars. The current likely design is a dual thermal/gas balloon that consists of a gas balloon suspended above a solar-heated thermal balloon. At night, the thermal balloon provides no lift, and the balloon system drifts just above the Martian surface; the lift of the gas balloon is just sufficient to prevent the science payload from hitting the ground. During the day, the balloon system flies at an altitude of 4 to 5 kilometers, rising due to the added lift provided by the thermal balloon. Over the course of a single Martian day, there may be winds in several directions, and in fact it can be expected that there will be winds simultaneously in different directions at different altitudes. Therefore, a balloon system capable of controlling its own altitude, via an autonomous flight control system, can take advantage of these different winds to control its direction, thereby greatly increasing both its mission utility and its longevity.
Under Pressure: Intraluminal Filling Pressures of Postpartum Hemorrhage Tamponade Balloons
Antony, Kathleen M.; Racusin, Diana A.; Belfort, Michael A.; Dildy, Gary A.
2017-01-01
Objective Uterine tamponade by fluid-filled balloons is now an accepted method of controlling postpartum hemorrhage. Available tamponade balloons vary in design and material, which affects the filling attributes and volume at which they rupture. We aimed to characterize the filling capacity and pressure-volume relationship of various tamponade balloons. Study Design Balloons were filled with water ex vivo. Intraluminal pressure was measured incrementally (every 10 mL for the Foley balloons and every 50 mL for all other balloons). Balloons were filled until they ruptured or until 5,000 mL was reached. Results The Foley balloons had higher intraluminal pressures than the larger-volume balloons. The intraluminal pressure of the Sengstaken-Blakemore tube (gastric balloon) was initially high, but it decreased until shortly before rupture occurred. The Bakri intraluminal pressure steadily increased until rupture occurred at 2,850 mL. The condom catheter, BT-Cath, and ebb all had low intraluminal pressures. Both the BT-Cath and the ebb remained unruptured at 5,000 mL. Conclusion In the setting of acute hemorrhage, expeditious management is critical. Balloons that have a low intraluminal pressure-volume ratio may fill more rapidly, more easily, and to greater volumes. We found that the BT-Cath, the ebb, and the condom catheter all had low intraluminal pressures throughout filling. PMID:28497006
Nácul, Miguel Prestes; Cavazzola, Leandro Totti; Loureiro, Marcelo de Paula; Bonin, Eduardo Aimoré; Ferreira, Paulo Roberto Walter
2015-09-01
To evaluate a new, low-cost, reusable balloon trocar device for dissection of the preperitoneal space during endoscopic surgery. Twenty swine (weight: 15-37 kg) were randomized to two groups, according to whether the preperitoneal space was created with a new balloon device manufactured by Bhio-Supply (group B) or with the commercially available OMSPDB 1000® balloon device manufactured by Covidien (group C). Quality and size of the created preperitoneal space, identification of anatomic structures, balloon dissection time, total procedure time, balloon resistance and internal pressure after insufflation with 300 mL of ambient air, balloon-related complications, and procedure cost were assessed. No significant differences in dissection time, total procedure time, or size of the created preperitoneal space were found between the groups. Balloons in group B had a significantly higher internal pressure compared to balloons in group C. None of the balloons ruptured during the experiment. Three animals in group C had balloon-related peritoneal lacerations. Despite a higher individual device cost, group B had a lower procedure cost over the entire experiment. The new balloon device is not inferior to the commercially available device in terms of the safety and effectiveness for creating a preperitoneal space in swine.
Chi, Heng; Li, Zhandong; Hansen, Bettina E; Yu, Tao; Zhang, Xiaoyong; Sun, Jian; Hou, Jinlin; Janssen, Harry L A; Peng, Jie
2018-06-11
Levels of antibodies against the hepatitis B virus (HBV) core protein (anti-HBc) have been associated with response to nucleos(t)ide analogue and (peg)interferon therapy in patients with chronic HBV infection. We performed a prospective study to determine whether the total serum level of anti-HBc level (immunoglobulins M and G) is associated with clinical relapse after discontinuation of nucleos(t)ide analogue-based therapy. We collected data from patients with chronic HBV infection who discontinued nucleos(t)ide analogue therapy according to pre-specified stopping criteria, recruited from November 2012 through July 2016 at an academic hospital in Guangzhou, China. Patients were followed through February 2017. We performed comprehensive biochemical and virologic tests at every visit, and anti-HBc was quantified for 2 years after treatment cessation (at baseline and weeks 4, 8, 12, 24, 48, and 96). The primary endpoint was clinical relapse, defined as level of HBV DNA >2000 IU/mL and level of alanine aminotransferase more than 2-fold the upper limit of normal-these were also the criteria for retreatment. We followed 100 patients (71% positive for HB e antigen [HBeAg] at the start of nucleos(t)ide analogue therapy, 43% treated with entecavir or tenofovir) for a median of 2.5 years after stopping therapy. Clinical relapse occurred in 39 patients (in 46% of patients at year 4 after discontinuation). High level of anti-HBc at the end of treatment (hazard ratio [HR], 0.31 per log IU/mL; P=.002) and low level of HB surface antigen (HBsAg) at the end of treatment (HR, 1.71 per log IU/mL; P=.032) were associated with a reduced risk of clinical relapse after adjusting for age, start of nucleos(t)ide analogue therapy HBeAg-status, and consolidation therapy duration. At year 4, 21% of patients with anti-HBc levels at the end of treatment ≥1000 IU/mL developed a clinical relapse compared to 85% of patients with levels <100 IU/mL (P<.001). An HBsAg level at the end of treatment ≤100 IU/mL was associated with a reduced risk of relapse (HR 0.30; P=.045). However, 82% of patients had levels of HBsAg above 100 IU/mL; for these patients, level of anti-HBc at the end of treatment could be used to determine the risk of relapse (HR 0.39 per log IU/mL; P=.005). In a median 2.5-year follow-up study of patients with chronic HBV infection who stopped nucleos(t)ide analogue therapy, total serum level of anti-HBc at the end of treatment was associated with risk of clinical relapse. Serum level of anti-HBc might be used to select patients suitable for discontinuing nucleos(t)ide analogue therapy. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
14 CFR 101.7 - Hazardous operations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...
14 CFR 101.7 - Hazardous operations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...
14 CFR 101.7 - Hazardous operations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...
14 CFR 101.7 - Hazardous operations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...
14 CFR 101.7 - Hazardous operations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...
Code of Federal Regulations, 2013 CFR
2013-01-01
... applicable requirements of this part. (c) For purposes of this part— (1) A captive gas balloon is a balloon that derives its lift from a captive lighter-than-air gas; (2) A hot air balloon is a balloon that... STANDARDS: MANNED FREE BALLOONS General § 31.1 Applicability. (a) This part prescribes airworthiness...
Code of Federal Regulations, 2012 CFR
2012-01-01
... applicable requirements of this part. (c) For purposes of this part— (1) A captive gas balloon is a balloon that derives its lift from a captive lighter-than-air gas; (2) A hot air balloon is a balloon that... STANDARDS: MANNED FREE BALLOONS General § 31.1 Applicability. (a) This part prescribes airworthiness...
Code of Federal Regulations, 2014 CFR
2014-01-01
... applicable requirements of this part. (c) For purposes of this part— (1) A captive gas balloon is a balloon that derives its lift from a captive lighter-than-air gas; (2) A hot air balloon is a balloon that... STANDARDS: MANNED FREE BALLOONS General § 31.1 Applicability. (a) This part prescribes airworthiness...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grena, Roberto
2010-04-15
Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)
NASA balloon design and flight - Philosophy and criteria
NASA Technical Reports Server (NTRS)
Smith, I. S., Jr.
1993-01-01
The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.
Sahin, Tayfun; Karauzum, Kurtulus; Ural, Ertan; Pedersen, Wesley R.
2018-01-01
Percutaneous balloon pulmonary valvuloplasty is the preferred therapy for pulmonary valve stenosis. However, the designs of the cylindrical balloons historically used for valvuloplasty have limitations, especially in patients who have large pulmonary annular diameters. The hourglass-shaped V8 Aortic Valvuloplasty Balloon may prove to be an effective alternative. The balloon has 2 large bulbous segments that are separated by a narrowed waist. The geometric shape is maintained throughout inflation, improving fixation and enabling broader leaflet opening. We present our first experience with the V8 balloon in 3 adults who had severe, symptomatic pulmonary valve stenosis. In addition to describing their cases, we detail our sizing technique for pulmonary valvuloplasty with the V8 balloon. Our successful results suggest that the V8 balloon is efficient and safe for balloon pulmonary valvuloplasty in adults with severe pulmonary valve stenosis. PMID:29844739
Sinha, Santosh Kumar; Mishra, Vikas; Razi, Mahmadula; Jha, Mukesh Jitendra
2017-10-04
Transcatheter therapy of valvular pulmonary stenosis is one of first catheter interventions facilitating its application in field of structural heart disease and now treatment of choice for significant pulmonary stenosis. Myriads of balloon catheter have been used for this purpose starting from Diamond (Boston Scientific,Natick, MA USA), Marshal (Medi-Tech,Watertown MAUSA), Innoue balloon, Tyshak I and currently Tyshak II. Diameter and length of balloon depend on size of annulus and age group, respectively. Problem with shorter balloon is difficulty in keeping it across the annulus while inflation as it tends to slip distally whereas with longer balloon, potential of tricuspid leak or conduction block as it may impinge on adjacent structures. Potential advantage of Accura balloon over Tyshak balloon lies in its peculiar shape while inflation and variable diameter, making stepwise dilatation possible. Here, we report a case of successful balloon pulmonary valvuloplasty using Accura balloon (Vascular Concept, UK) with little modification of conventional technique. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Scientific Ballooning in India - Recent Developments
NASA Astrophysics Data System (ADS)
Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.
Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.
Gonzalez, Raul; Schuster, Randi Melissa; Mermelstein, Robin J.; Vassileva, Jasmin; Martin, Eileen M.; Diviak, Kathleen R.
2012-01-01
Recent studies suggest that abstinent cannabis users show deficits on neurocognitive laboratory tasks of impulsive behavior. But results are mixed and less is known on the performance of non-treatment seeking, young adult cannabis users. Importantly, relationships between performance on measures of impulsive behavior and symptoms of cannabis addiction remain relatively unexplored. We compared young adult current cannabis users (CU, n = 65) and non-using controls (NU, n = 65) on several laboratory measures of impulsive behavior, as well as on a measure of episodic memory commonly impacted by cannabis use. The CU group performed more poorly than the NU group on the Hopkins Verbal Learning Test-Revised Total Immediate Recall and Delayed Recall. No significant differences were observed on the measures of impulsive behavior (i.e., Iowa Gambling Task [IGT], Go-Stop Task, Monetary Choice Questionnaire, Balloon Analogue Risk Task). We examined relationships between neurocognitive performance and symptoms of cannabis use disorder symptoms (DSM-IV CUD) among the CU group, which revealed that poorer IGT performance was associated with more symptoms of DSM-IV CUD. Our results show poorer memory performance among young adult cannabis users relative to healthy controls, but no differences on measures of impulsive behavior. However, performance on a specific type of impulsive behavior (i.e., poorer decision-making) was associated with more cannabis use disorder symptoms. These results provide preliminary evidence to suggest that decision-making deficits may be more strongly associated with problems experienced from cannabis use, rather than solely being a consequence of cannabis use, per se. PMID:22882144
Ahn, Woo-Young; Vassileva, Jasmin
2016-01-01
Background Recent animal and human studies reveal distinct cognitive and neurobiological differences between opiate and stimulant addictions; however, our understanding of the common and specific effects of these two classes of drugs remains limited due to the high rates of polysubstance-dependence among drug users. Methods The goal of the current study was to identify multivariate substance-specific markers classifying heroin dependence (HD) and amphetamine dependence (AD), by using machine-learning approaches. Participants included 39 amphetamine mono-dependent, 44 heroin mono-dependent, 58 polysubstance dependent, and 81 non-substance dependent individuals. The majority of substance dependent participants were in protracted abstinence. We used demographic, personality (trait impulsivity, trait psychopathy, aggression, sensation seeking), psychiatric (attention deficit hyperactivity disorder, conduct disorder, antisocial personality disorder, psychopathy, anxiety, depression), and neurocognitive impulsivity measures (Delay Discounting, Go/No-Go, Stop Signal, Immediate Memory, Balloon Analogue Risk, Cambridge Gambling, and Iowa Gambling tasks) as predictors in a machine-learning algorithm. Results The machine-learning approach revealed substance-specific multivariate profiles that classified HD and AD in new samples with high degree of accuracy. Out of 54 predictors, psychopathy was the only classifier common to both types of addiction. Important dissociations emerged between factors classifying HD and AD, which often showed opposite patterns among individuals with HD and AD. Conclusions These results suggest that different mechanisms may underlie HD and AD, challenging the unitary account of drug addiction. This line of work may shed light on the development of standardized and cost-efficient clinical diagnostic tests and facilitate the development of individualized prevention and intervention programs for HD and AD. PMID:26905209
Hamidovic, Ajna; Kang, Un Jung; de Wit, Harriet
2008-02-01
The neurotransmitter dopamine is integrally involved in the rewarding effects of drugs, and it has also been thought to mediate impulsive behaviors in animal models. Most of the studies of drug effects on impulsive behaviors in humans have involved drugs with complex actions on different transmitter systems and different receptor subtypes. The present study was designed to characterize the effect of single doses of pramipexole, a D2/D3 agonist, on measures of cognitive and impulsive behavior, as well as on mood in healthy volunteers. Healthy men and women (N = 10) received placebo and 2 doses of pramipexole, 0.25 and 0.50 mg, in a within-subject, double-blinded study. Outcome measures included changes in cognitive performance, assessed by the Automated Neuropsychological Assessment Metrics, several behavioral measures related to impulsive behavior, including the Balloon Analogue Risk Task, Delay Discounting Task, Go/No-Go Task, Card Perseveration Task, and subjective ratings of mood assessed by Addiction Research Center Inventory, Profile of Mood States, and Drug Effects Questionnaire. Pramipexole decreased positive ratings of mood (euphoria, intellectual efficiency, and energy) and increased both subjectively reported sedation and behavioral sedation indicated by impaired cognitive performance on several measures of the Automated Neuropsychological Assessment Metrics. Single low to medium doses of this drug did not produce a decrease in impulsive responding on behavioral measures included in this study. The sedative-like effects observed in this study may reflect presynaptic actions of the drug. Higher doses with postsynaptic actions may be needed to produce either behavioral or subjective stimulant-like effects.
Pressure monitoring predicts pulmonary vein occlusion in cryoballoon ablation.
Sunaga, Akihiro; Masuda, Masaharu; Asai, Mitsutoshi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Syota; Mano, Toshiaki
2018-04-10
Pulmonary venography is routinely used to confirm pulmonary vein (PV) occlusion during cryoballoon ablation. However, this technique is significantly limited by the risks associated with contrast media, such as renal injury and contrast allergy. We hypothesized that PV occlusion can be predicted by elevation of the balloon catheter tip pressure, avoiding the need for contrast media. Forty-eight consecutive patients with paroxysmal atrial fibrillation who underwent PV isolation with the cryoballoon technique were enrolled. The balloon catheter tip pressure was measured in each PV before and after balloon inflation. We analyzed 200 applications of cryoballoon ablation in 185 PVs (excluding 3 common PVs and 1 extremely small right inferior PV) of 48 patients (age, 70 ± 11 years; male, n = 28; mean left atrial diameter, 38 ± 6 mm). Compared with patients with unsuccessful occlusion, patients with successful occlusion demonstrated a larger change in pressure after balloon inflation (6 ± 8 vs. 2 ± 4 mmHg, P < 0.001), a lower minimum temperature (- 49 ± 6 vs. - 40 ± 8 °C, P < 0.001), and a higher PV isolation rate (97 vs. 64%, P < 0.001). The best cutoff value of a change in pressure for predicting PV occlusion was 4.5 mmHg, with a sensitivity of 67%, specificity of 83%, and predictive accuracy of 72%. Pressure monitoring is helpful to confirm PV occlusion during cryoballoon ablation.
Zhai, Yan; Zhang, Zihan; Wang, Wei; Zheng, Tingping; Zhang, Huili
2018-01-01
Heavy menstrual bleeding is a common problem that can severely affect quality of life. To compare bipolar radiofrequency endometrial ablation and thermal balloon ablation for heavy menstrual bleeding in terms of efficacy and health-related quality of life (HRQoL). Online registries were systematically searched using relevant terms without language restriction from inception to November 24, 2016. Randomized control trials or cohort studies of women with heavy menstrual bleeding comparing the efficacy of two treatments were eligible. Data were extracted. Results were expressed as risk ratios (RRs) or weighted mean differences (WMDs) with 95% confidence intervals (CIs). Six studies involving 901 patients were included. Amenorrhea rate at 12 months was significantly higher after bipolar radiofrequency endometrial ablation than after thermal balloon ablation (RR 2.73, 95% CI 2.00-3.73). However, no difference at 12 months was noted for dysmenorrhea (RR 1.04, 95% CI 0.68-1.58) or treatment failure (RR 0.78, 95% CI 0.38-1.60). The only significant difference for HRQoL outcomes was for change in SAQ pleasure score (12 months: WMD -3.51, 95% CI -5.42 to -1.60). Bipolar radiofrequency endometrial ablation and thermal balloon ablation reduce menstrual loss and improve quality of life. However, bipolar radiofrequency endometrial ablation is more effective in terms of amenorrhea rate and SAQ pleasure. © 2017 International Federation of Gynecology and Obstetrics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopera, Jorge E., E-mail: Lopera@uthscsa.ed; Alvarez, Alex; Trimmer, Clayton
2009-01-15
The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm{sup 3}, respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containingmore » a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.« less
Retained intraaortic balloon. Case report and review of the literature.
Grande, A M; Martinelli, L; Graffigna, A; Viganò, M
1995-01-01
We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home.
Scientific ballooning in India Recent developments
NASA Astrophysics Data System (ADS)
Manchanda, R. K.
Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.
Secco, Gioel Gabrio; Ghione, Matteo; Mattesini, Alessio; Dall'Ara, Gianni; Ghilencea, Liviu; Kilickesmez, Kadriye; De Luca, Giuseppe; Fattori, Rossella; Parisi, Rosario; Marino, Paolo Nicola; Lupi, Alessandro; Foin, Nicolas; Di Mario, Carlo
2016-06-20
Calcific coronary lesions impose a rigid obstacle to optimal balloon and stent expansion and the 20 to 30 atm limit that non-compliant (NC) balloons reach can be insufficient. The aim of our study was to evaluate the safety and efficacy of a new dedicated super high-pressure NC balloon (OPN NC®; SIS Medical AG, Winterthur, Switzerland). We retrospectively evaluated a consecutive series of 91 lesions in which conventional NC balloons at maximal pressure failed to achieve an adequate post-dilatation luminal gain and were therefore treated with an OPN NC balloon up to 40 atm. Angiographic success was defined as residual angiographic diameter stenosis <30%. MLD and %DS were measured at baseline, after NC balloon, OPN NC balloon and stent implantation. Angiographic success was achieved in 84 lesions (92.3%). All of the remaining lesions received rotational atherectomy with the exception of two cases in which rotational atherectomy was not attempted because of small vessel size and excessive tortuosity. MLD and acute gain were significantly greater and %DS was significantly lower post OPN NC balloon compared with conventional NC balloon inflation (p<0.001). No coronary perforations occurred. No acute or 30-day follow-up MACE was reported. When conventional NC balloons fail, the new OPN NC dedicated high-pressure balloon provides an effective and safe alternative strategy for the dilatation of resistant coronary lesions.
Stability analysis and trend study of a balloon tethered in a wind, with experimental comparisons
NASA Technical Reports Server (NTRS)
Redd, L. T.; Bland, S. R.; Bennett, R. M.
1973-01-01
A stability analysis and trend study for a balloon tethered in a steady wind are presented. The linearized, stability-derivative type analysis includes balloon aerodynamics, buoyancy, mass (including apparent mass), and static forces resulting from the tether cable. The analysis has been applied to a balloon 7.64 m in length, and the results are compared with those from tow tests of this balloon. This comparison shows that the analysis gives reasonable predictions for the damping, frequencies, modes of motion, and stability boundaries exhibited by the balloon. A trend study for the 7.64-m balloon was made to illustrate how the stability boundaries are affected by changes in individual stability parameters. The trends indicated in this study may also be applicable to many other tethered-balloon systems.
A comparative study of internally and externally capped balloons using small scale test balloons
NASA Technical Reports Server (NTRS)
Bell, Douglas P.
1994-01-01
Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.
Scientific Balloons for Venus Exploration
NASA Astrophysics Data System (ADS)
Cutts, James; Yavrouian, Andre; Nott, Julian; Baines, Kevin; Limaye, Sanjay; Wilson, Colin; Kerzhanovich, Viktor; Voss, Paul; Hall, Jeffery
Almost 30 years ago, two balloons were successfully deployed into the atmosphere of Venus as an element of the VeGa - Venus Halley mission conducted by the Soviet Union. As interest in further Venus exploration grows among the established planetary exploration agencies - in Europe, Japan, Russia and the United States, use of balloons is emerging as an essential part of that investigative program. Venus balloons have been proposed in NASA’s Discovery program and ESA’s cosmic vision program and are a key element in NASA’s strategic plan for Venus exploration. At JPL, the focus for the last decade has been on the development of a 7m diameter superpressure pressure(twice that of VeGa) capable of carrying a 100 kg payload (14 times that of VeGA balloons), operating for more than 30 days (15 times the 2 day flight duration of the VeGa balloons) and transmitting up to 20 Mbit of data (300 times that of VeGa balloons). This new generation of balloons must tolerate day night transitions on Venus as well as extended exposure to the sulfuric acid environment. These constant altitude balloons operating at an altitude of about 55 km on Venus where temperatures are benign can also deploy sondes to sound the atmosphere beneath the probe and deliver deep sondes equipped to survive and operate down to the surface. The technology for these balloons is now maturing rapidly and we are now looking forward to the prospects for altitude control balloons that can cycle repeatedly through the Venus cloud region. One concept, which has been used for tropospheric profiling in Antarctica, is the pumped-helium balloon, with heritage to the anchor balloon, and would be best adapted for flight above the 55 km level. Phase change balloons, which use the atmosphere as a heat engine, can be used to investigate the lower cloud region down to 30 km. Progress in components for high temperature operation may also enable investigation of the deep atmosphere of Venus with metal-based balloons.
Ballooning Then...and Ballooning Now.
ERIC Educational Resources Information Center
Journal of Aerospace Education, 1978
1978-01-01
Describes the history of hot-air balloon travel, starting with its French origins and continuing through to the 1978 national championship. An address for Balloon Federation of America membership is included. (MA)
Single balloon versus double balloon bipedicular kyphoplasty: a systematic review and meta-analysis.
Jing, Zehao; Dong, Jianli; Li, Zhengwei; Nan, Feng
2018-06-19
Kyphoplasty has been widely used to treat vertebral compression fractures (VCFs). In standard procedure of kyphoplasty, two balloons were inserted into the vertebral body through bipedicular and inflated simultaneously, while using a single balloon two times is also a common method in clinic to lessen the financial burden of patients. However, the effect and safety of single balloon versus double balloon bipedicular kyphoplasty are still controversy. In this systematic review and meta-analysis, eligible studies were identified through a comprehensive literature search of PubMed, Cochrane library EMBASE, Web of Science, Wanfang, CNKI, VIP and CBM until January 1, 2018. Results from individual studies were pooled using a random or fixed effects model. Seven articles were included in the systematic review and five studies were consisted in meta-analysis. We observed no significant difference between single balloon and double balloon bipedicular kyphoplasty in visual analog scale (VAS), angle (kyphotic angle and Cobb angle), consumption (operation time, cement volume and volume of bleeding), vertebral height (anterior height, medium height and posterior height) and complications (cement leakage and new VCFs), while the cost of single balloon bipedicular kyphoplasty is lower than that of double balloon bipedicular kyphoplasty. The results of our meta-analysis also demonstrated that single balloon can significantly improve the VAS, angle and vertebral height of patients suffering from VCFs. This systematic review and meta-analysis collectively concludes that single balloon bipedicular kyphoplasty is as effective as double balloon bipedicular kyphoplasty in improving clinical symptoms, deformity and complications of VCFs but not so expensive. These slides can be retrieved under Electronic Supplementary Material.
Wan, You-Dong; Sun, Tong-Wen; Kan, Quan-Cheng; Guan, Fang-Xia; Liu, Zi-Qi; Zhang, Shu-Guang
2016-01-01
Background Intra-aortic balloon pumps (IABP) have generally been used for patients undergoing high-risk mechanical coronary revascularization. However, there is still insufficient evidence to determine whether they can improve outcomes in reperfusion therapy patients, mainly by percutaneous coronary intervention (PCI) with stenting or coronary artery bypass graft (CABG). This study was designed to determine the difference between high-risk mechanical coronary revascularization with and without IABPs on mortality, by performing a meta-analysis on randomized controlled trials of the current era. Methods Pubmed and Embase databases were searched from inception to May 2015. Unpublished data were obtained from the investigators. Randomized clinical trials of IABP and non-IABP in high-risk coronary revascularization procedures (PCI or CABG) were included. In the case of PCI procedures, stents should be used in more than 80% of patients. Numbers of events at the short-term and long-term follow-up were extracted. Results A total of 12 randomized trials enrolling 2155 patients were included. IABPs did not significantly decrease short-term mortality (relative risk (RR) 0.66; 95% CI, 0.42–1.01), or long-term mortality (RR 0.79; 95% CI, 0.47–1.35), with low heterogeneity across the studies. The findings remained stable in patients with acute myocardial infarction with or without cardiogenic shock. But in high-risk CABG patients, IABP was associated with reduced mortality (71 events in 846 patients; RR 0.40; 95%CI 0.25–0.67). Conclusion In patients undergoing high-risk coronary revascularization, IABP did not significantly decrease mortality. But high-risk CABG patients may be benefit from IABP. Rigorous criteria should be applied to the use of IABPs. PMID:26784578
Retained intraaortic balloon. Case report and review of the literature.
Grande, A M; Martinelli, L; Graffigna, A; Viganò, M
1995-01-01
We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home. Images PMID:8605436
The French balloon and sounding rocket space program
NASA Astrophysics Data System (ADS)
Coutin/Faye, S.; Sadourny, I.
1987-08-01
Stratospheric and long duration flight balloon programs are outlined. Open stratospheric balloons up to 1 million cu m volume are used to carry astronomy, solar system, aeronomy, stratosphere, biology, space physics, and geophysics experiments. The long duration balloons can carry 50 kg payloads at 20 to 30 km altitude for 10 days to several weeks. Pressurized stratospheric balloons, and infrared hot air balloons are used. They are used to study the dynamics of stratospheric waves and atmospheric water vapor. Laboratories participating in sounding rocket programs are listed.
2012-01-01
Background Radiolabelled bombesin (BN) conjugates are promising radiotracers for imaging and therapy of breast and prostate tumours, in which BN2/gastrin-releasing peptide receptors are overexpressed. We describe the influence of the specific activity of a 177Lu-DOTA-PEG5k-Lys-B analogue on its therapeutic efficacy and compare it with its non-PEGylated counterpart. Methods Derivatisation of a stabilised DOTA-BN(7–14)[Cha13,Nle14] analogue with a linear PEG molecule of 5 kDa (PEG5k) was performed by PEGylation of the ϵ-amino group of a β3hLys-βAla-βAla spacer between the BN sequence and the DOTA chelator. The non-PEGylated and the PEGylated analogues were radiolabelled with 177Lu. In vitro evaluation was performed in human prostate carcinoma PC-3 cells, and in vivo studies were carried out in nude mice bearing PC-3 tumour xenografts. Different specific activities of the PEGylated BN analogue and various dose regimens were evaluated concerning their therapeutic efficacy. Results The specificity and the binding affinity of the BN analogue for BN2/GRP receptors were only slightly reduced by PEGylation. In vitro binding kinetics of the PEGylated analogue was slower since steady-state condition was reached after 4 h. PEGylation improved the stability of BN conjugate in vitro in human plasma by a factor of 5.6. The non-PEGylated BN analogue showed favourable pharmacokinetics already, i.e. fast blood clearance and renal excretion, but PEGylation improved the in vivo behaviour further. One hour after injection, the tumour uptake of the PEG5k-BN derivative was higher compared with that of the non-PEGylated analogue (3.43 ± 0.63% vs. 1.88 ± 0.4% ID/g). Moreover, the increased tumour retention resulted in a twofold higher tumour accumulation at 24 h p.i., and increased tumour-to-non-target ratios (tumour-to-kidney, 0.6 vs. 0.4; tumour-to-liver, 8.8 vs. 5.9, 24 h p.i.). In the therapy study, both 177Lu-labelled BN analogues significantly inhibited tumour growth. The therapeutic efficacy was highest for the PEGylated derivative of high specific activity administered in two fractions (2 × 20 MBq = 40 MBq) at day 0 and day 7 (73% tumour growth inhibition, 3 weeks after therapy). Conclusions PEGylation and increasing the specific activity enhance the pharmacokinetic properties of a 177Lu-labelled BN-based radiopharmaceutical and provide a protocol for targeted radionuclide therapy with a beneficial anti-tumour effectiveness and a favourable risk-profile at the same time. PMID:22681935
Calculating Payload for a Tethered Balloon System
Charles D. Tangren
1980-01-01
A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....
NASA Astrophysics Data System (ADS)
Riedler, W.; Torkar, K.
1996-05-01
This issue is grouped into sections on materials, design, performance and analysis of balloons, reviews of major national and international balloon programmes, novel instrumentation and systems for scientific ballooning, and selected recent scientific observations.
Accurate Determination of the Volume of an Irregular Helium Balloon
ERIC Educational Resources Information Center
Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine
2013-01-01
In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…
Risky decision-making in children with and without ADHD: A prospective study.
Humphreys, Kathryn L; Tottenham, Nim; Lee, Steve S
2018-02-01
Learning from past decisions can enhance successful decision-making. It is unclear whether difficulties in learning from experience may contribute to risky decision-making, which may be altered among individuals with attention-deficit/hyperactivity disorder (ADHD). This study follows 192 children with and without ADHD aged 5 to 10 years for approximately 2.5 years and examines their risky decision-making using the Balloon Emotional Learning Task (BELT), a computerized assessment of sequential risky decision-making in which participants pump up a series of virtual balloons for points. The BELT contains three task conditions: one with a variable explosion point, one with a stable and early explosion point, and one with a stable and late explosion point. These conditions may be learned via experience on the task. Contrary to expectations, ADHD status was not found to be related to greater risk-taking on the BELT, and among younger children ADHD status is in fact associated with reduced risk-taking. In addition, the typically-developing children without ADHD showed significant learning-related gains on both stable task conditions. However, the children with ADHD demonstrated learning on the condition with a stable and early explosion point, but not on the condition with the stable and late explosion point, in which more pumps are required before learning when the balloon will explode. Learning during decision-making may be more difficult for children with ADHD. Because adapting to changing environmental demands requires the use of feedback to guide future behavior, negative outcomes associated with childhood ADHD may partially reflect difficulties in learning from experience.
Atherectomy for peripheral arterial disease.
Ambler, Graeme K; Radwan, Rami; Hayes, Paul D; Twine, Christopher P
2014-03-17
Symptomatic peripheral arterial disease may be treated by a number of options including exercise therapy, angioplasty, stenting and bypass surgery. Atherectomy is an alternative technique where atheroma is excised by a rotating cutting blade. The objective of this review was to analyse randomised controlled trials comparing atherectomy against any established treatment for peripheral arterial disease in order to evaluate the effectiveness of atherectomy. The Cochrane Peripheral Vascular Diseases Group Trials Search Co-ordinator searched the Specialised Register (last searched November 2013) and CENTRAL (2013, Issue 10). Trials databases were searched for details of ongoing or unpublished studies. Randomised controlled trials (RCTs) comparing atherectomy and other established treatments were selected for inclusion. All participants had symptomatic peripheral arterial disease with either claudication or critical limb ischaemia and evidence of lower limb arterial disease. Two review authors (GA and CT) screened studies for inclusion, extracted data and assessed the quality of the trials. Any disagreements were resolved through discussion. Four trials were included with a total of 220 participants (118 treated with atherectomy, 102 treated with balloon angioplasty) and 259 treated vessels (129 treated with atherectomy, 130 treated with balloon angioplasty). All studies compared atherectomy with angioplasty. No study was properly powered or assessors blinded to the procedures and there was a high risk of selection, attrition, detection and reporting biases.The estimated risk of success was similar between the treatment modalities although the confidence interval (CI) was compatible with small benefits of either treatment for the initial procedural success rate (Mantel-Haenszel risk ratio (RR) 0.92, 95% CI 0.44 to 1.91, P = 0.82), patency at six months (Mantel-Haenszel RR 0.92, 95% CI 0.51 to 1.66, P = 0.79) and patency at 12 months (Mantel-Haenszel RR 1.17, 95% CI 0.72 to 1.90, P = 0.53) following the procedure. The reduction in all-cause mortality with atherectomy was most likely due to an unexpectedly high mortality in the balloon angioplasty group in one of the two trials that reported mortality (Mantel-Haenszel RR 0.24, 95% CI 0.06 to 0.91, P = 0.04). Cardiovascular events were not reported in any study. There was a reduction in the rate of bailout stenting following atherectomy (Mantel-Haenszel RR 0.45, 95% CI 0.24 to 0.84, P = 0.01), and balloon inflation pressures were lower following atherectomy (mean difference -2.73 mmHg, 95% CI -3.48 to -1.98, P < 0.00001). Complications such as embolisation and vessel dissection were reported in two trials indicating more embolisations in the atherectomy group and more vessel dissections in the angioplasty group, but the data could not be pooled. From the limited data available, there was no clear evidence of different rates of adverse events between the atherectomy and balloon angioplasty groups for target vessel revascularisation and above-knee amputation. Quality of life and clinical and symptomatic outcomes such as walking distance or symptom relief were not reported in the studies. This review has identified poor quality evidence to support atherectomy as an alternative to balloon angioplasty in maintaining primary patency at any time interval. There was no evidence for superiority of atherectomy over angioplasty on any outcome, and distal embolisation was not reported in all trials of atherectomy. Properly powered trials are recommended.
The National Scientific Balloon Facility. [balloon launching capabilities of ground facility
NASA Technical Reports Server (NTRS)
Kubara, R. S.
1974-01-01
The establishment and operation of the National Scientific Balloon Facility are discussed. The balloon launching capabilities are described. The ground support systems, communication facilities, and meteorological services are analyzed.
Esrange Space Center, a Gate to Space
NASA Astrophysics Data System (ADS)
Widell, Ola
Swedish Space Corporation (SSC) is operating the Esrange Space Center in northern Sweden. Space operations have been performed for more than 40 years. We have a unique combination of maintaining balloon and rocket launch operations, and building payloads, providing space vehicles and service systems. Sub-orbital rocket flights with land recovery and short to long duration balloon flights up to weeks are offered. The geographical location, land recovery area and the long term experience makes Swedish Space Corporation and Esrange to an ideal gate for space activities. Stratospheric balloons are primarily used in supporting atmospheric research, validation of satellites and testing of space systems. Balloon operations have been carried out at Esrange since 1974. A large number of balloon flights are yearly launched in cooperation with CNES, France. Since 2005 NASA/CSBF and Esrange provide long duration balloon flights to North America. Flight durations up to 5 days with giant balloons (1.2 Million cubic metres) carrying heavy payload (up to 2500kg) with astronomical instruments has been performed. Balloons are also used as a crane for lifting space vehicles or parachute systems to be dropped and tested from high altitude. Many scientific groups both in US, Europe and Japan have indicated a great need of long duration balloon flights. Esrange will perform a technical polar circum balloon flight during the summer 2008 testing balloon systems and flight technique. We are also working on a permission giving us the opportunity on a circular stratospheric balloon flight around the North Pole.
Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.
Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K
2018-01-01
Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.
Etienne, Pierre Yves; Papadatos, Spiridon; Glineur, David; Mairy, Yves; El Khoury, Elie; Noirhomme, Philippe; El Khoury, Gebrine
2007-08-01
Preoperative intraaortic balloon pump (IABP) counterpulsation has better outcomes compared with perioperative or postoperative insertion in critical patients, and off-pump surgical procedures have been advocated to reduce mortality in high-risk patients. However, some surgeons are reluctant to perform beating heart operations in specific patient subgroups, including those with unstable angina or patients with low ejection fraction, because of their possible perioperative hemodynamic instability. We evaluated combined beating heart procedures and preoperative IABP in selected high-risk patients and compared our results with the predictive European System for Cardiac Operative Risk Evaluation (EuroSCORE) model. Fifty-five high-risk patients with a mean logistic EuroSCORE of 24 were prospectively enrolled and then divided into emergency (group 1, n = 25) and nonemergency (group 2, n = 30) groups. IABP was inserted immediately before operation in group 1 and the day before the procedure in group 2. Compared with the EuroSCORE predictive model, a dramatic decrease in mortality occurred in both groups. Group I predicted mortality was 36.8%, and observed was 20%; and group 2 predicted mortality was 15.2% and observed was 0%. No specific complications from the use of IABP were encountered. During mid-term (2 years) follow-up, no patient died from a cardiac cause or required percutaneous coronary intervention or subsequent reoperation due to incomplete revascularization. The combined use of preoperative intraaortic counterpulsation and beating heart intervention allows complete revascularization in high-risk patients with a important reduction in operative mortality and excellent mid-term results.
A new idea for a safer approach to the supra-aortic trunks: the Piton™ catheter.
Setacci, C; Moratto, R; Sirignano, P; Setacci, F; Silingardi, R; Coppi, G
2011-04-01
Carotid artery disease is among the most common causes of stroke, and stroke is the third leading cause of death in industrialized countries. Thus the personal health and socioeconomic burden of carotid artery disease is significant. Carotid artery disease accounts for approximately 5-12% of new strokes in patients amenable to revascularization therapy. Atherosclerosis is the main reason for stroke and accounts for approximately one third of all cases. Carotid stenting is nowadays considered a valid standard alternative to surgical carotid endarterectomy, especially in patients having a high perioperative risk. The first carotid balloon angioplasty was carried out in 1979 and the first carotid balloon-expandable bare metal stents were implanted 10 years later, in 1989. However, carotid stenting at that time was associated with major complications, due to extrinsic compression and subsequent to the steel stents used. The Piton™ GC (carotid guide catheter) is intended to facilitate the introduction and placement of interventional devices (e.g., guidewires, stent delivery systems, dilation balloons, angiographic- or micro-catheters, etc.) into the human vasculature to treat vascular obstructive disease, including but not limited to the supra-aortic vessels.
Hedberg, Pia; Eklund, Carolina; Högqvist, Sandra
2015-06-01
The most common complication due to intubation is a high cuff pressure. A high cuff pressure can cause postanesthetic tracheal mucosal injuries in patients undergoing surgery. The aim of this cross-sectional study was to describe whether anesthetic nurses and anesthesiologists identified a very high cuff pressure by manual palpation of the external cuff balloon on an endotracheal tube. An airway device was intubated with an endotracheal tube cuffed to 95 cm H2O. Each participant palpated the external cuff balloon and then filled out a questionnaire, including estimation of the cuff pressure and user frequency of the cuff pressure manometer. The results showed that 89.1% estimated that the cuff pressure was high. Among the participants who rated the cuff pressure as high, 44.8% rated the pressure as quite high and 60.6% rated the pressure as very high. There was no significant relationship between profession and skill in identifying a very high cuff pressure (P = .843) or between work experience and skill in terms of identifying a very high cuff pressure (P = .816). These findings indicate that 10% of patients are at risk of tracheal erosion because of a high cuff pressure.
NASA Technical Reports Server (NTRS)
1990-01-01
The principal method of dealing with coronary artery blockage is bypass surgery. A non-surgical alternative available to some patients is balloon angioplasty. For several years, medical researchers have been exploring another alternative that would help a wider circle of patients than the balloon treatment and entail less risk than bypass surgery. A research group is on the verge of an exciting development: laser angioplasty with a 'cool' type of laser, called an excimer laser, that does not damage blood vessel walls and offers non-surgical cleansing of clogged arteries with extraordinary precision. The system is the Dymer 200+ Excimer Laser Angioplasty System, developed by Advanced Intraventional Systems. Used in human clinical tests since 1987, the system is the first fully integrated 'cool' laser capable of generating the requisite laser energy and delivering the energy to target arteries. Thirteen research hospitals in the U.S. have purchased Dymer 200+ systems and used them in clinical trials in 121 peripheral and 555 coronary artery cases. The success rate in opening blocked coronary arteries is 85 percent, with fewer complications than in balloon angioplasty. Food and Drug Administration approval for the system is hoped for in the latter part of 1990. * Advanced Intraventional Systems became Spectranetics in 1994 and discontinued the product.
Using analogues to quantify geological uncertainty in stochastic reserve modelling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wells, B.; Brown, I.
1995-08-01
The petroleum industry seeks to minimize exploration risk by employing the best possible expertise, methods and tools. Is it possible to quantify the success of this process of risk reduction? Due to inherent uncertainty in predicting geological reality and due to changing environments for hydrocarbon exploration, it is not enough simply to record the proportion of successful wells drilled; in various parts of the world it has been noted that pseudo-random drilling would apparently have been as successful as the actual drilling programme. How, then, should we judge the success of risk reduction? For many years the E&P industry hasmore » routinely used Monte Carlo modelling to generate a probability distribution for prospect reserves. One aspect of Monte Carlo modelling which has received insufficient attention, but which is essential for quantifying risk reduction, is the consistency and repeatability with which predictions can be made. Reducing the subjective element inherent in the specification of geological uncertainty allows better quantification of uncertainty in the prediction of reserves, in both exploration and appraisal. Building on work reported at the AAPG annual conventions in 1994 and 1995, the present paper incorporates analogue information with uncertainty modelling. Analogues provide a major step forward in the quantification of risk, but their significance is potentially greater still. The two principal contributors to uncertainty in field and prospect analysis are the hydrocarbon life-cycle and the geometry of the trap. These are usually treated separately. Combining them into a single model is a major contribution to the reduction risk. This work is based in part on a joint project with Oryx Energy UK Ltd., and thanks are due in particular to Richard Benmore and Mike Cooper.« less
Hardell, L; Mild, K H; Carlberg, M
2002-10-01
To investigate the use of cellular and cordless phones and the risk for malignant brain tumours. A case-control study was performed on 649 patients aged 20-80 years of both sexes with malignant brain tumour diagnosed from 1 January 1997 to 30 June 2000. All patients were alive during the time of the study and had histopathology verified brain tumours. One matched control to each case was selected from the Swedish Population Register. The study area was the Uppsala-Orebro, Stockholm, Linköping and Göteborg medical regions of Sweden. Exposure was assessed by a questionnaire answered by 588 (91%) cases and 581 (90%) controls. Phone usage was defined as 'ever use' and usage starting within 1 year before diagnosis was disregarded. Overall, no significantly increased risks were found: analogue cellular phones yielded an odds ratio (OR)=1.13, 95% confidence interval (CI)=0.82-1.57, digital cellular phones OR=1.13, CI=0.86-1.48, and cordless phones OR=1.13, CI=0.85-1.50. For ipsilateral (same side) radiofrequency exposure, analogue mobile phones gave OR=1.85, CI=1.16-2.96, for all malignant brain tumours. For astrocytoma, this risk was OR=1.95, CI=1.12-3.39. For all malignant brain tumours, digital mobile phones yielded OR=1.59, CI=1.05-2.41, and cordless phones yielded OR=1.46, CI=0.96-2.23, in the analysis of ipsilateral exposure. The ipsilateral use of an analogue cellular phone yielded a significantly increased risk for malignant brain tumours.
Investigating Diffusion and Entropy with Carbon Dioxide-Filled Balloons
ERIC Educational Resources Information Center
Jadrich, James; Bruxvoort, Crystal
2010-01-01
Fill an ordinary latex balloon with helium gas and you know what to expect. Over the next day or two the volume will decrease noticeably as helium escapes from the balloon. So what happens when a latex balloon is filled with carbon dioxide gas? Surprisingly, carbon dioxide balloons deflate at rates as much as an order of magnitude faster than…
Current trends of balloon laryngoplasty in Thailand.
Moungthong, Greetha; Bunbanjerdsuk, Sacarin; Wright, Nida; Sathavornmanee, Thanakrit; Setabutr, Dhave
2017-06-01
To describe the current trend in balloon laryngoplasty usage and experience by practicing otolaryngologists in Thailand. Anonymous 11 question online and paper survey of otolaryngologists on their current balloon laryngoplasty practices. Current practices and experience in balloon laryngoplasty were queried with multiple choice and open-ended questions. Laser use is the most commonly utilized instrument to treat airway stenosis in Thailand. 86% of respondents do not have experience with balloon dilatation; yet, almost half (47.6%) report they perform a minimum of five airway surgeries per year. Most respondents had been in practice for less than 6 years (41%) and reported that they did not have exposure to balloon use during residency training. The largest barrier reported for the use of balloon instrumentation in the airway is inexperience (44.4%) followed by cost (38.3%), yet most feel that treatment in airway stenosis could benefit by usage of balloons (95.5%). Most otolaryngologists in Thailand do not have experience with the use of balloon dilatation and lack of exposure remains the largest barrier to its use. Otolaryngologists in Thailand feel that increased usage of balloons in the airway could improve airway stenosis treatment in the country.
NASA Astrophysics Data System (ADS)
Yoshida, Tetsuya; Fuke, Hideyuki; Shoji, Yasuhiro; Iijima, Issei; Izutsu, Naoki; Kato, Yoichi; Matsuzaka, Yukihiko; Mizuta, Eiichi; Sato, Takatoshi; Tamura, Keisuke; Saito, Yoshitaka; Kakehashi, Yuya
2012-07-01
Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency conducts domestic balloon campaigns at Taiki Aerospace Research Field (TARF) in Hokkaido since 2008. The ballooning at TARF becomes stable after four year operation. Because the field faces to the Pacific Ocean, heavy balloons and payloads can be launched safely using a very unique sliding launcher. Recoveries at the inshore along the Tokachi coast can be done very quickly and smoothly. Unfortunately, flight opportunities are recently limited due to unfriendly weather condition. Unstable Jet stream also prevents us to have so-called `boomerang flight' to achieve long flight duration more than several hours. Six balloon-borne experiments were carried out in 2010 and 2011. Three of them were demonstrations of challenges of space engineering, two were in-situ atmospheric observation, and one was the technical flight of new high-resolution γ-ray telescope. In addition to these flights, we carried out two launches for next generation balloons: one for Tawara-shaped superpressure balloon and the other for ultra-thin high-altitude balloon. In this paper, recent activities of the Japanese scientific balloon program will be introduced. On-going development of the balloon system will also be presented.
Development of a super-pressure balloon with a diamond-shaped net
NASA Astrophysics Data System (ADS)
Saito, Y.; Iijima, I.; Matsuzaka, Y.; Matsushima, K.; Tanaka, S.; Kajiwara, K.; Shimadu, S.
2014-10-01
The essential reason of the lobed-pumpkin shaped super-pressure balloon to withstand against the high pressure is that the local curvature of the balloon film is kept small. Recently, it has been found that the small local curvature can also be obtained if the balloon is covered by a diamond-shaped net with a vertically elongated shape. The development of the super-pressure balloon using this method was started from a 3-m balloon with a polyethylene film covered by a net using Kevlar ropes. The ground inflation test showed the expected high burst pressure. Then, a 6-m and a 12-m balloon using a polyethylene film and a net using the Vectran were developed and stable deployment was checked through the ground inflation tests. The flight test of a 3000 m3 balloon was performed in 2013 and shown to resist a pressure of at least 400 Pa. In the future, after testing a new design to relax a possible stress concentration around the polar area, test flights of scaled balloons will be performed gradually enlarging their size. The goal is to launch a 300,000 m3 super-pressure balloon.
Hu, Hong-Tao; Shin, Ji Hoon; Kim, Jin-Hyoung; Jang, Jong Keon; Park, Jung-Hoon; Kim, Tae-Hyung; Nam, Deok Ho; Song, Ho-Young
2015-07-01
We aimed to evaluate the safety and clinical effectiveness of fluoroscopically guided large balloon dilatation for treating congenital esophageal stenosis in children. Our study included seven children (mean age 4.0 years) who underwent a total of ten balloon dilatation sessions. The initial balloon diameters were 10-15 mm. The technical success, clinical success (improved food intake and reduced dysphagia within 1 month following the first balloon dilatation), dysphagia recurrence, and complications were retrospectively evaluated. Technical and clinical success rates were 100 %. During the mean 38-month follow-up period after the first balloon dilatation, 3 (43 %) patients underwent only one additional balloon dilatation 4-5 months after the first balloon dilatation for dysphagia recurrence. Two of them showed improvement without further recurrence, while the remaining one underwent partial esophagectomy. Well-contained transmural esophageal rupture (type 2) occurred in two (29 %, 2/7) patients and during two (20 %, 2/10) balloon dilatation sessions. All ruptures were successfully treated conservatively. Our study showed that fluoroscopically guided large balloon dilatation seems to be a simple and effective primary treatment technique for congenital esophageal stenosis in children. Esophageal ruptures were not uncommon although they were not fatal.
Wang, Dongyu; Xu, Shuqia; Qiu, Xiwen; Zhu, Caixia; Li, Zhuyu; Wang, Zilian; Hou, Hongying; Gao, Yu; Wang, Xiaoyi; He, Ping; Qin, Yiwei; Liu, Lihua
2017-12-18
To evaluate the success rate and protocol of the Bakri balloon for postpartum hemorrhage (PPH) in the course of a prospective observational multicenter cohort study in South China. At 20 hospitals in South China, women with postpartum bleeding who failed to respond to the first-line conservative management and received the Bakri balloon were recruited for the study. Maternal characteristics, PPH characteristics, PPH management and outcomes in regard to the Bakri balloon use were recorded. A total of 472 women had a Bakri balloon tamponade and 407 (86.23%) women were enrolled (67 after vaginal delivery and 340 either during or after cesarean delivery). The success rate of the Bakri balloon in this study was 91.65% (373/407 women). During vaginal deliveries, the group with a hemorrhage >2000 mL before balloon insertion had significantly more blood loss (551.67±635.17 mL vs. 242.06±313.69 mL, P=0.039) and lower maternal hemoglobin (73±21.77 g/L vs. 92.06±19.60 g/L, P=0.029) after using Bakri balloon than the group with a hemorrhage <1000 mL. Similar data were found during cesarean deliveries. The blood loss before and after balloon insertion were significantly higher in the Bakri balloon failure group (1700±1429.88 mL before and 1209.58±1139.72 mL after using the balloon) than those in the success group [918±493.92 mL before (P=0.002) and 266.57±361.60 mL after using the balloon (P=0.001)]. Rapid diagnosis or prognosis of PPH, in combination with early usage of the Bakri postpartum balloon is more effective for the management of PPH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoshimatsu, Rika; Yamagami, Takuji, E-mail: yamagami@kochi-u.ac.jp; Ishikawa, Masaki
2016-06-15
PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumormore » enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.« less
Testing of the Anorectal and Pelvic Floor Area
... minutes and is well tolerated by most people. Balloon capacity and compliance A balloon capacity and compliance ... while measurements of volume and pressure are recorded. Balloon evacuation study A balloon evacuation study tests pelvic ...
On the response of superpressure balloons to displacements from equilibrium density level
NASA Technical Reports Server (NTRS)
Levanon, N.; Kushnir, Y.
1976-01-01
The response of a superpressure balloon to an initial displacement from its constant-density floating level is examined. An approximate solution is obtained to the governing vertical equation of motion for constant-density superpressure balloons. This solution is used to filter out neutrally buoyant oscillations in balloon records despite the nonlinear behavior of the balloon. The graph depicting the pressure data after deconvolution between the raw pressure data and the normalized balloon wavelet shows clearly the strong filtering-out of the neutral buoyancy oscillations.
Risk Factors of Acute Pancreatitis in Oral Double Balloon Enteroscopy.
Kopáčová, Marcela; Bureš, Jan; Rejchrt, Stanislav; Vávrová, Jaroslava; Bártová, Jolana; Soukup, Tomáš; Tomš, Jan; Tachecí, Ilja
Double balloon enteroscopy (DBE) was introduced 15 years ago. The complications of diagnostic DBE are rare, acute pancreatitis is most redoubtable one (incidence about 0.3%). Hyperamylasemia after DBE seems to be a rather common condition respectively. The most probable cause seems to be a mechanical straining of the pancreas. We tried to identify patients in a higher risk of acute pancreatitis after DBE. We investigated several laboratory markers before and after DBE (serum cathepsin B, lactoferrin, E-selectin, SPINK 1, procalcitonin, S100 proteins, alfa-1-antitrypsin, hs-CRP, malondialdehyde, serum and urine amylase and serum lipase). Serum amylase and lipase rose significantly with the maximum 4 hours after DBE. Serum cathepsin and procalcitonin decreased significantly 4 hours after DBE compared to healthy controls and patients values before DBE. Either serum amylase or lipase 4 hours after DBE did not correlate with any markers before DBE. There was a trend for an association between the number of push-and-pull cycles and procalcitonin and urine amylase 4 hours after DBE; between procalcitonin and alfa-1-antitrypsin, cathepsin and hs-CRP; and between E-selectin and malondialdehyde 4 hours after DBE. We found no laboratory markers determinative in advance those patients in a higher risk of acute pancreatitis after DBE.
Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.
NASA Astrophysics Data System (ADS)
Vasudevan, Rajagopalan
2012-07-01
The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.
Embolization of direct carotid cavernous fistulas with the novel double-balloon technique
Niu, Yin; Li, Lin; Tang, Jun; Zhu, Gang
2015-01-01
Multiple endovascular management of direct carotid cavernous fistula (CCF) has been widely accepted as a treatment option. Embolization of the fistula with detachable balloons or thrombogenic coil-based occlusion has been the main choice to treat direct CCF, with good safety and efficacy. This study investigated the safety and efficacy of embolization of direct CCF with the novel double-balloon technique. A retrospective review of a prospective database on cerebral vascular disease was performed. We identified a total of five patients presenting with high-flow direct CCF. All patients were managed with transarterial embolization with the novel double-balloon technique. Three of the five patients were treated with two detachable balloons, and a completely occluded fistula with preservation of the internal carotid artery was achieved. Of the remaining two patients treated with more detachable balloons, one patient achieved a perfect outcome and the other one suffered from recurrent fistula due to balloon migration 3 weeks after embolization. During a follow-up period of 12–18 months, no symptoms reoccurred in any patient. Thus, the double-balloon treatment may be a promising method for CCF complete occlusion. This novel technique may bring more benefits in the following two cases: 1). A single inflated detachable balloon fails to completely occlude the CCF, which causing the next balloon can not pass into the fistula. 2). A giant CCF needs more balloons for fistula embolization. PMID:26586136
A buoyant tornado-probe concept incorporating an inverted lifting device. [and balloon combination
NASA Technical Reports Server (NTRS)
Grant, F. C.
1973-01-01
Addition of an inverted lifting device to a simple balloon probe is shown to make possible low-altitude entry to tornado cores with easier launch conditions than for the simple balloon probe. Balloon-lifter combinations are particularly suitable for penetration of tornadoes with average to strong circulation, but tornadoes of less than average circulation which are inaccessible to simple balloon probes become accessible. The increased launch radius which is needed for access to tornadoes over a wide range of circulation results in entry times of about 3 minutes. For a simple balloon probe the uninflated balloon must be first dropped on, or near, the track of the tornado from a safe distance. The increase in typical launch radius from about 0.75 kilometer to slightly over 1.0 kilometer with a balloon-lifter combination suggests that a direct air launch may be feasible.
NASA Technical Reports Server (NTRS)
Shibasaki, K.; Iwagami, N.; Ogawa, T.
1985-01-01
As a part of the Japanese activities of MAP in the Antarctica, balloon-borne measurements of the stratospheric NO2 profile were planned and carried out by the JARE 23rd and 24th wintering parties. Few results have been reported so far as the stratospheric NO2 profile at high latitude. There were no reported balloon measurements carried out in the Southern Hemisphere. Profiles are presented for the first balloon-borne measurement of the stratospheric NO2 in the Antarctica. Three balloons named JA21, JA25 and JA26 were launched from Syowa Station (69 deg S, 35.6 deg E) using 5000 cu. cm plastic balloons. JA21 balloon was launched on November 24, 1982, and JA25 and JA26 balloons on November 12 and 20, 1983, respectively.
Vargas, Eric J; Pesta, Carl M; Bali, Ahmad; Ibegbu, Eric; Bazerbachi, Fateh; Moore, Rachel L; Kumbhari, Vivek; Sharaiha, Reem Z; Curry, Trace W; DosSantos, Gina; Schmitz, Ramsey; Agnihotri, Abhishek; Novikov, Aleksey A; Pitt, Tracy; Dunlap, Margo K; Herr, Andrea; Aronne, Louis; Ledonne, Erin; Kadouh, Hoda C; Cheskin, Lawrence J; Mundi, Manpreet S; Acosta, Andres; Gostout, Christopher J; Abu Dayyeh, Barham K
2018-07-01
The Orbera intragastric balloon (OIB) is a single fluid-filled intragastric balloon approved for the induction of weight loss and treatment of obesity. However, little is known about the effectiveness and safety of the OIB outside clinical trials, and since approval, the Food and Drug Administration has issued warnings to health care providers about risk of balloon hyperinflation requiring early removal, pancreatitis, and death. We analyzed data on patients who have received the OIB since its approval to determine its safety, effectiveness, and tolerance in real-world clinical settings. We performed a postregulatory approval study of the safety and efficacy of the OIB, and factors associated with intolerance and response. We collected data from the Mayo Clinic's database of patient demographics, outcomes of OIB placement (weight loss, weight-related comorbidities), technical aspects of insertion and removal, and adverse events associated with the device and/or procedure, from 8 centers (3 academic, 5 private, 4 surgeons, and 4 gastroenterologists). Our final analysis comprised 321 patients (mean age, 48.1 ± 11.9 y; 80% female; baseline body mass index, 37.6 ± 6.9). Exploratory multivariable linear and logistic regression analyses were performed to identify predictors of success and early balloon removal. Primary effectiveness outcomes were percentage of total body weight lost at 3, 6, and 9 months. Primary and secondary safety outcomes were rates of early balloon removal, periprocedural complications, dehydration episodes requiring intravenous infusion, balloon migration, balloon deflation or hyperinflation, pancreatitis, or other complications. Four patients had contraindications for placement at the time of endoscopy. The balloon was safely removed in all instances with an early removal rate (before 6 months) in 16.7% of patients, at a median of 8 weeks after placement (range, 1-6 mo). Use of selective serotonin or serotonin-norepinephrine re-uptake inhibitors at the time of balloon placement was associated with increased odds of removal before 6 months (odds ratio, 3.92; 95% CI, 1.24-12.41). Total body weight lost at 3 months was 8.5% ± 4.9% (n = 204), at 6 months was 11.8% ± 7.5% (n = 199), and at 9 months was 13.3% ± 10% (n = 47). At 6 months, total body weight losses of 5%, 10%, and 15% were achieved by 88%, 62%, and 31% of patients, respectively. Number of follow-up visits and weight loss at 3 months were associated with increased weight loss at 6 months (β = 0.5 and 1.2, respectively) (P < .05). Mean levels of cholesterol, triglycerides, low-density lipoprotein, and hemoglobin A1c, as well as systolic and diastolic blood pressure, were significantly improved at 6 months after OIB placement (P < .05). In an analysis of a database of patients who received endoscopic placement of the OIB, we found it to be safe, effective at inducing weight loss, and to reduce obesity-related comorbidities in a real-world clinical population. Rates of early removal (before 8 weeks) did not differ significantly between clinical trials and the real-world population, but were affected by use of medications. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
La Frenais, R.; Saraceno, T.; Powell, J.
2014-04-01
Is it possible for spaceflight to become more sustainable? Artist and architect Tomas Saraceno proposes a long-term artscience research project based on his initial work with solar balloons to join with the efforts of engineers such as John Powell, working on the Airship to Orbit experiments, which describe a three stage process of using airships to fly to a large suborbital "Dark Sky Station' then literally floating into orbit with additional electrical and chemical propulsion. (See: http://www.jpaerospace.com) In his artworks Tomás Saraceno proposes cell-like flying cities as possible architectonic living spaces in direct reference to Buckminster Fuller's Cloud Nine (circa 1960). The fantastic architectural utopia Cloud Nine consists of a freely floating sphere measuring one mile in diameter that offers living space to several autonomous communities encompassing thousands of inhabitants each. The notion of the cloud is essential to the artist's work. The cloud as metaphor stands for artistic intention, for the meaning of territory and border in today's (urban) society, and for exploring possibilities for the sustainable development of the human living environment. In Saraceno's work this environment is not limited to the earth, but is explicitly conceived to reach into outer space. (Biomimetic Constructions- On the works of Tomás Saraceno By Katharina Schlüter) Saraceno is also interested in human factors experiments using his existing constructions as analogue environments for living on Mars and is proposing carry out a series of workshops, experiments and solar balloon launces in White Sands desert in early 2016 in collaboration with the curator Dr Rob La Frenais, the Rubin Center at The University of Texas at El Paso and various scientific partners.
European Venus Explorer: An in-situ mission to Venus using a balloon platform
NASA Astrophysics Data System (ADS)
Chassefière, E.; Korablev, O.; Imamura, T.; Baines, K. H.; Wilson, C. F.; Titov, D. V.; Aplin, K. L.; Balint, T.; Blamont, J. E.; Cochrane, C. G.; Ferencz, Cs.; Ferri, F.; Gerasimov, M.; Leitner, J. J.; Lopez-Moreno, J.; Marty, B.; Martynov, M.; Pogrebenko, S. V.; Rodin, A.; Whiteway, J. A.; Zasova, L. V.; the EVE Team
2009-07-01
Planetary balloons have a long history already. A small super-pressure balloon was flown in the atmosphere of Venus in the eighties by the Russian-French VEGA mission. For this mission, CNES developed and fully tested a 9 m diameter super-pressure balloon, but finally replaced it by a smaller one due to mass constraints (when it was decided to send Vega to Halley's Comet). Furthermore, several kinds of balloons have been proposed for planetary exploration [Blamont, J., in: Maran, S.P. (Ed.), The Astronomy and Astrophysics Encyclopedia. Cambridge University Press, p. 494, 1991]. A Mars balloon has been studied for the Mars-94 Russian-French mission, which was finally cancelled. Mars and Venus balloons have also been studied and ground tested at JPL, and a low atmosphere Venus balloon is presently under development at JAXA (the Japanese Space Agency). Balloons have been identified as a key element in an ongoing Flagship class mission study at NASA, with an assumed launch date between 2020 and 2025. Recently, it was proposed by a group of scientists, under European leadership, to use a balloon to characterize - by in-situ measurements - the evolution, composition and dynamics of the Venus atmosphere. This balloon is part of a mission called EVE (European Venus Explorer), which has been proposed in response to the ESA AO for the first slice of the Cosmic Vision program by a wide international consortium including Europe, Russia, Japan and USA. The EVE architecture consists of one balloon platform floating at an altitude of 50-60 km, one short lived probe provided by Russia, and an orbiter with a polar orbit to relay data from the balloon and probe, and to perform remote sensing science observations. The balloon type preferred for scientific goals is one, which would oscillate in altitude through the cloud deck. To achieve this flight profile, the balloon envelope would contain a phase change fluid. While this proposal was not selected for the first slice of Cosmic Vision missions, it was ranked first among the remaining concepts within the field of solar system science.
Gomes, Fabio P; Shaw, P Nicholas; Whitfield, Karen; Hewavitharana, Amitha K
2015-09-03
Milk is an important source of nutrients for various risk populations, including infants. The accurate measurement of vitamin D in milk is necessary to provide adequate supplementation advice for risk groups and to monitor regulatory compliance. Currently used liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods are capable of measuring only four analogues of vitamin D in unfortified milk. We report here an accurate quantitative analytical method for eight analogues of vitamin D: Vitamin D2 and D3 (D2 and D3), 25-hydroxy D2 and D3, 24,25-dihydroxy D2 and D3, and 1,25-dihydroxyD2 and D3. In this study, we compared saponification and protein precipitation for the extraction of vitamin D from milk and found the latter to be more effective. We also optimised the pre-column derivatisation using 4-phenyl-l,2,4-triazoline-3,5-dione (PTAD), to achieve the highest sensitivity and accuracy for all major vitamin D forms in milk. Chromatography was optimised to reduce matrix effects such as ion-suppression, and the matrix effects were eliminated using co-eluting stable isotope labelled internal standards for the calibration of each analogue. The analogues, 25-hydroxyD3 (25(OH)D3) and its epimer (3-epi-25(OH)D3) were chromatographically resolved, to prevent over-estimation of 25(OH)D3. The method was validated and subsequently applied for the measurement of total vitamin D levels in human, cow, mare, goat and sheep milk samples. The detection limits, repeatability standard deviations, and recovery ranges were from 0.2 to 0.4 femtomols, 6.30-13.5%, and 88.2-105%, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.
Dronedarone: an amiodarone analogue.
Doggrell, Sheila A; Hancox, Jules C
2004-04-01
Of the antiarrhythmic drugs in current use, amiodarone is one of the most effective and is associated with a comparatively low risk of drug-induced pro-arrhythmia, probably due to its multiple pharmacological actions on cardiac ion channels and receptors. However, amiodarone is associated with significant extra-cardiac side effects and this has driven development of amiodarone analogues. These analogues include short acting analogues (e.g., AT-2001) with similar acute effects to amiodarone, the thyroid receptor antagonist KB-130015 and dronedarone. Dronedarone, (SR-33589; Sanofi-Synthelabo), is a non-iodinated amiodarone derivative that inhibits Na +, K + and Ca 2+ currents. It is a potent inhibitor of the acetylcholine-activated K + current from atrial and sinoatrial nodal tissue, and inhibits the rapid delayed rectifier more potently than slow and inward rectifier K + currents and inhibits L-type calcium current. Dronedarone is an antagonist at alpha- and beta-adrenoceptors and unlike amiodarone, has little effect at thyroid receptors. Dronedarone is more potent than amiodarone in inhibiting arrhythmias and death in animal models of ischaemia- and reperfusion-induced arrhythmias. In the Dronedarone Atrial Fibrillation Study After Electrical Cardioversion (DAFNE) clinical trial, dronedarone 800 mg/day appeared to be effective and safe for the prevention of atrial fibrillation relapses after cardioversion. The Antiarrhythmic Trial with Dronedarone in Moderate-to-Severe Congestive Heart Failure Evaluating Morbidity Decrease (ANDROMEDA) trial was stopped due to a potential increased risk of death in the dronedarone group. Trials of dronedarone in the maintenance of sinus rhythm in patients with atrial fibrillation and a safety and tolerability study in patients with an implantable cardioverter defibrillator are ongoing. Further experimental and clinical studies are required before we have a definitive answer to whether dronedarone has advantages over amiodarone and other amiodarone analogues.
Jagadeesan, Bharathi D; Grigoryan, Mikayel; Hassan, Ameer E; Grande, Andrew W; Tummala, Ramachandra P
2013-12-01
Ethylene vinyl alcohol copolymer (Onyx) is widely used for the embolization of arteriovenous malformations (AVMs) of the brain, head, and neck. Balloon-assisted Onyx embolization may provide additional unique advantages in the treatment of AVMs in comparison with traditional catheter-based techniques. To report our initial experience in performing balloon-assisted AVM embolization for brain and neck AVMs with the use of the new Scepter-C and Scepter-XC coaxial dual-lumen balloon microcatheters. Balloon-assisted transarterial embolization was performed in a series of 7 patients with AVMs (4 with brain AVMs, 1 with a dural arteriovenous fistula, and 2 with neck AVMs) by using Onyx delivered through the lumen of Scepter-C or Scepter XC coaxial balloon microcatheters. Following the initial balloon-catheter navigation into a feeding artery and the subsequent inflation of the balloon, the embolization was performed by using Onyx 18, Onyx 34, or both. A total of 12 embolization sessions were performed via 17 arterial feeders in these 7 patients. In 1 patient, there was an arterial perforation from the inflation of the balloon; in all others, the embolization goals were successfully achieved with no adverse events. The balloon microcatheters showed excellent navigability, and there were no problems with retrieval or with the repeated inflation and deflation of the balloons. A proximal Onyx plug, which is crucial in many AVM embolizations, was not necessary with this technique. Additionally, fluoroscopy and procedural times seemed lower with this technique compared with conventional embolization methods.
Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop
2015-01-01
Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.
Thermal performance modeling of NASA s scientific balloons
NASA Astrophysics Data System (ADS)
Franco, H.; Cathey, H.
The flight performance of a scientific balloon is highly dependant on the interaction between the balloon and its environment. The balloon is a thermal vehicle. Modeling a scientific balloon's thermal performance has proven to be a difficult analytical task. Most previous thermal models have attempted these analyses by using either a bulk thermal model approach, or by simplified representations of the balloon. These approaches to date have provided reasonable, but not very accurate results. Improvements have been made in recent years using thermal analysis tools developed for the thermal modeling of spacecraft and other sophisticated heat transfer problems. These tools, which now allow for accurate modeling of highly transmissive materials, have been applied to the thermal analysis of NASA's scientific balloons. A research effort has been started that utilizes the "Thermal Desktop" addition to AUTO CAD. This paper will discuss the development of thermal models for both conventional and Ultra Long Duration super-pressure balloons. This research effort has focused on incremental analysis stages of development to assess the accuracy of the tool and the required model resolution to produce usable data. The first stage balloon thermal analyses started with simple spherical balloon models with a limited number of nodes, and expanded the number of nodes to determine required model resolution. These models were then modified to include additional details such as load tapes. The second stage analyses looked at natural shaped Zero Pressure balloons. Load tapes were then added to these shapes, again with the goal of determining the required modeling accuracy by varying the number of gores. The third stage, following the same steps as the Zero Pressure balloon efforts, was directed at modeling super-pressure pumpkin shaped balloons. The results were then used to develop analysis guidelines and an approach for modeling balloons for both simple first order estimates and detailed full models. The development of the radiative environment and program input files, the development of the modeling techniques for balloons, and the development of appropriate data output handling techniques for both the raw data and data plots will be discussed. A general guideline to match predicted balloon performance with known flight data will also be presented. One long-term goal of this effort is to develop simplified approaches and techniques to include results in performance codes being developed.
Solar energy collector including a weightless balloon with sun tracking means
Hall, Frederick F.
1978-01-01
A solar energy collector having a weightless balloon, the balloon including a transparent polyvinylfluoride hemisphere reinforced with a mesh of ropes secured to its outside surface, and a laminated reflector hemisphere, the inner layer being clear and aluminized on its outside surface and the outer layer being opaque, the balloon being inflated with lighter-than-air gas. A heat collection probe extends into the balloon along the focus of reflection of the reflective hemisphere for conducting coolant into and out of the balloon. The probe is mounted on apparatus for keeping the probe aligned with the sun's path, the apparatus being founded in the earth for withstanding wind pressure on the balloon. The balloon is lashed to the probe by ropes adhered to the outer surface of the balloon for withstanding wind pressures of 100 miles per hour. Preferably, the coolant is liquid sodium-potassium eutectic alloy which will not normally freeze at night in the temperate zones, and when heated to 4,000.degree. R exerts a pressure of only a few atmospheres.
3,4-Methylenedioxy analogues of amphetamine: defining the risks to humans.
Hegadoren, K M; Baker, G B; Bourin, M
1999-03-01
The 3,4-methylenedioxy analogues of amphetamine [MDMA ("Ecstasy", "Adam"), MDA ("Love") and MDE ("Eve")] are recreational drugs that produce feelings of euphoria and energy and a desire to socialize, which go far to explain their current popularity as "rave drugs". In addition to these positive effects, the drugs are relatively inexpensive to purchase and have the reputation of being safe compared to other recreational drugs. Yet there is mounting evidence that these drugs do not deserve this reputation of being safe. This review examines the relevant human and animal literature to delineate the possible risks MDMA, MDA and MDE engender with oral consumption in humans. Following a summary of the behavioral and cognitive effects of MDMA, MDA and MDE, risks will be discussed in terms of toxicity, psychopathology, neurotoxicity, abuse potential and the potential for drug-drug interactions associated with acute and chronic use.
Ballooning Comes of Age: Make Your Own Balloon.
ERIC Educational Resources Information Center
Eckford, Jim
1983-01-01
Provides instructions for building a working model of a hot-air balloon, offering suggestions for a successful flight. Indicates that children can be involved in the projects, for example, by filling in colors in the panels of a balloon drawing. (JN)
Flow Past a Descending Balloon
NASA Technical Reports Server (NTRS)
Baginski, Frank
2001-01-01
In this report, we present our findings related to aerodynamic loading of partially inflated balloon shapes. This report will consider aerodynamic loading of partially inflated inextensible natural shape balloons and some relevant problems in potential flow. For the axisymmetric modeling, we modified our Balloon Design Shape Program (BDSP) to handle axisymmetric inextensible ascent shapes with aerodynamic loading. For a few simple examples of two dimensional potential flows, we used the Matlab PDE Toolbox. In addition, we propose a model for aerodynamic loading of strained energy minimizing balloon shapes with lobes. Numerical solutions are presented for partially inflated strained balloon shapes with lobes and no aerodynamic loading.
Vuruskan, Ertan; Saracoglu, Erhan; Ergun, Ugur; Poyraz, Fatih; Duzen, İrfan Veysel
2017-01-01
The aim of this study was to compare the simultaneous double-protection method (proximal balloon plus distal filter) with distal-filter protection or proximal-balloon protection alone in asymptomatic patients during carotid artery stenting. 119 consecutive patients were investigated for carotid artery stentings in the extracranial internal carotid artery with the use of distal filters (n = 41, 34.4 %), proximal balloon (MoMa) protection (n = 40, 33.6 %) or double protection (n = 38, 31.9 %). Magnetic resonance imaging (MRI) was performed on all patients before the procedure, and control diffusion-weighted MRI (DW-MRI) was obtained within 24-48 h after the procedure. Procedural data, complications, success rate, major adverse cardiovascular events, and MRI findings were collected. New cerebral high-intensity (HI) lesions were observed in 47 (39.4 %) patients. HI lesions were observed in 22 (53.6 %), 15 (37.5 %), and 10 (26.3 %) of the patients with distal filters, proximal protection, and double protection, respectively (p = 0.004). The average number of HI lesions on DW-MRI was 1.80 in the distal-filter group, 0.90 in the proximal-balloon group, and 0.55 in the double-protection group (p < 0.001). Procedure and fluoroscopy times were slightly longer in the double-protection group compared to the distal- or proximal-protection groups (p = 0.001). The double (proximal plus distal) cerebral embolic protection technique is safe and effective for minimizing the risk of cerebral embolization, even in patients with asymptomatic carotid artery stenosis, despite slightly longer procedure and fluoroscopy times. .
Scholz, Karl Heinrich; Maier, Sebastian K G; Maier, Lars S; Lengenfelder, Björn; Jacobshagen, Claudius; Jung, Jens; Fleischmann, Claus; Werner, Gerald S; Olbrich, Hans G; Ott, Rainer; Mudra, Harald; Seidl, Karlheinz; Schulze, P Christian; Weiss, Christian; Haimerl, Josef; Friede, Tim; Meyer, Thomas
2018-04-01
The aim of this study was to investigate the effect of contact-to-balloon time on mortality in ST-segment elevation myocardial infarction (STEMI) patients with and without haemodynamic instability. Using data from the prospective, multicentre Feedback Intervention and Treatment Times in ST-Elevation Myocardial Infarction (FITT-STEMI) trial, we assessed the prognostic relevance of first medical contact-to-balloon time in n = 12 675 STEMI patients who used emergency medical service transportation and were treated with primary percutaneous coronary intervention (PCI). Patients were stratified by cardiogenic shock (CS) and out-of-hospital cardiac arrest (OHCA). For patients treated within 60 to 180 min from the first medical contact, we found a nearly linear relationship between contact-to-balloon times and mortality in all four STEMI groups. In CS patients with no OHCA, every 10-min treatment delay resulted in 3.31 additional deaths in 100 PCI-treated patients. This treatment delay-related increase in mortality was significantly higher as compared to the two groups of OHCA patients with shock (2.09) and without shock (1.34), as well as to haemodynamically stable patients (0.34, P < 0.0001). In patients with CS, the time elapsing from the first medical contact to primary PCI is a strong predictor of an adverse outcome. This patient group benefitted most from immediate PCI treatment, hence special efforts to shorten contact-to-balloon time should be applied in particular to these high-risk STEMI patients. NCT00794001.
Hot-air balloon tours: crash epidemiology in the United States, 2000-2011.
Ballard, Sarah-Blythe; Beaty, Leland P; Baker, Susan P
2013-11-01
Hot-air balloon tours are FAR Part 91-governed balloon rides conducted for compensation or hire. Part 91, General Aviation, in general involves the least strict federal regulations and accounts for the majority of aviation crashes and fatalities. National Transportation Safety Board reports of hot-air balloon tour crashes in the United States from 2000 through 2011 were read and analyzed. During the 12-yr period, 78 hot-air balloon tours crashed, involving 518 occupants. There were 91 serious injuries and 5 fatalities; 83% of crashes resulted in one or more serious or fatal outcomes. Of the serious injuries characterized, 56% were lower extremity fractures. Most crashes (81%) occurred during landing; 65% involved hard landings. Fixed object collisions contributed to 50% of serious injuries and all 5 fatalities. During landing sequences, gondola dragging, tipping, bouncing, and occupant ejection were associated with poor outcomes. Of the crashes resulting in serious or fatal outcomes, 20% of balloons were significantly damaged or destroyed. The incidence of morbidity and mortality is high among hot-air balloon tour crashes, and the proportion of balloon crashes attributed to paid rides appears to have increased over time. In addition to examining the role of restraint systems, personal protective equipment, and power line emergency procedures in ballooning, injury prevention efforts should target factors such hard landings, object strikes, gondola instability, and occupant ejections, which are associated with balloon injuries and deaths. Crash outcomes may also improve with vehicle engineering that enables balloons themselves to absorb impact forces.
Policy issues in space analogues
NASA Astrophysics Data System (ADS)
Auger, Robin N.; Facktor, Debra D.
Space mission planning is increasingly focusing on destinations beyond Earth orbit. Advancements in technology will inevitably be required to enable long-duration human spaceflight missions, and breakthroughs in the policy arena will also be needed to achieve success in such missions. By exploring how policy issues have been addressed in analogous extreme environments, policymakers can develop a framework for addressing these issues as they apply to long-term human spaceflight. Policy issues that need to be addressed include: crew selection, training, organization, and activities, medical testing, illness, injury, and death; communication; legal accountability and liability; mission safety and risk management; and environmental contamination. This paper outlines the approach of a study underway by The George Washington University and ANSER to examine how these policy issues have been addressed in several analogues and how the experiences of these analogues can help formulate policies for long-duration human spaceflight missions. Analogues being studied include Antarctic bases, submarine voyages, undersea stations, Biosphere 2, and the U.S. Skylab and Russian Mir space stations.
... with a balloon catheter and expands when the balloon is inflated. The stent is then left there to help keep the artery open. ... with a balloon catheter and expands when the balloon is inflated. The stent is then left there to help keep the artery open.
Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation.
Khir, Ashraf William; Bruti, Gianpaolo
2013-07-01
It has been observed that operating the intra-aortic balloon at an angle to the horizontal resulted in a reduction of the volume displaced toward the coronary arteries and compromised afterload reduction. Therefore, the aim of this work is to examine whether changing the current balloon shape, which has not been altered for 40 years, could compensate for the negative hemodynamic effects due to angulation. We tested two tapered balloons, increasing diameter (TID) and decreasing diameter (TDD), and compared the results with those obtained from a standard cylindrical balloon. The balloons were tested in vitro at 60 beats/min and a static pressure of 90 mm Hg. The balloons were operated at four angles (0°, 20°, 30°, 45°), and the pressure at three locations along the balloon (base, middle, and tip) was also measured. Flow rate upstream of the tip of the balloon was also measured to indicate the flow displaced toward the coronary circulation. The relative volume displaced toward (VUTVi) and suctioned away from (VUTVd) the simulated ascending aorta, during inflation and deflation, respectively, is reduced when a standard cylindrical balloon is operated at an angle to the horizontal. The TDD provided the greatest VUTVi and also produced the largest pulse pressure during deflation. Although the TID provided less VUTVi and VUTVd at smaller angles, it was not markedly affected by the change of angle. According to these results, different balloon shapes analyzed, with comparable volume to that of a cylindrical balloon, produced greater inflation and deflation benefits, at the horizontal and at a range of angles to the horizontal. Further investigations are required to optimize the shape of the tapered balloons to fit into the available physiological space. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.
O'Shea, Owen R; Hamann, Mark; Smith, Walter; Taylor, Heidi
2014-02-15
Efforts to curb pollution in the marine environment are covered by national and international legislation, yet weather balloons are released into the environment with no salvage agenda. Here, we assess impacts associated with weather balloons in the Great Barrier Reef World Heritage Area (GBRWHA). We use modeling to assess the probability of ocean endpoints for released weather balloons and predict pathways post-release. In addition, we use 21 months of data from beach cleanup events to validate our results and assess the abundance and frequency of weather balloon fragments in the GBRWHA. We found between 65% and 70% of balloons land in the ocean and ocean currents largely determine final endpoints. Beach cleanup data revealed 2460 weather balloon fragments were recovered from 24 sites within the GBRWHA. This is the first attempt to quantify this problem and these data will add support to a much-needed mitigation strategy for weather balloon waste. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ko, Gi-Young; Song, Ho-Young, E-mail: hysong@amc.seoul.kr; Hong, Heuk-Jin
2003-04-15
Purpose: To assess the efficacy of balloon dilation combined with chemotherapy and/or radiation therapy for palliation of dysphagia due to malignant esophagogastric junction strictures. Methods: Fluoroscopically guided balloon dilation was attempted in 20 patients. The causes of strictures were gastric adenocarcinoma (n = 10) and esophageal squamous cell carcinoma (n = 10). Scheduled chemotherapy and/or radiation therapy followed balloon dilation in all patients. Results: There were no technical failures or major complications. After balloon dilation, 15 (75%) patients showed improvement of dysphagia. No patient complained of reflux esophagitis during the follow-up period. Among the 15 patients, seven needed no furthermore » treatment for palliation of dysphagia until their deaths. The remaining eight patients underwent repeat balloon dilation(n = 4) or stent placement (n = 4)3-43 weeks (mean 15 weeks) after the initial balloon dilation because of recurrent dysphagia. Conclusion: Balloon dilation combined with chemotherapy and/or radiation therapy seems to be an easy and reasonably effective palliative treatment for malignant esophagogastric strictures.« less
Davidson, Anders J; Russo, Rachel M; Ferencz, Sarah-Ashley E; Cannon, Jeremy W; Rasmussen, Todd E; Neff, Lucas P; Johnson, M Austin; Williams, Timothy K
2017-07-01
To avoid potential cardiovascular collapse after resuscitative endovascular balloon occlusion of the aorta (REBOA), current guidelines recommend methodically deflating the balloon for 5 minutes to gradually reperfuse distal tissue beds. However, anecdotal evidence suggests that this approach may still result in unpredictable aortic flow rates and hemodynamic instability. We sought to characterize aortic flow dynamics following REBOA as the balloon is deflated in accordance with current practice guidelines. Eight Yorkshire-cross swine were splenectomized, instrumented, and subjected to rapid 25% total blood volume hemorrhage. After 30 minutes of shock, animals received 60 minutes of Zone 1 REBOA with a low-profile REBOA catheter. During subsequent resuscitation with shed blood, the aortic occlusion balloon was gradually deflated in stepwise fashion at the rate of 0.5 mL every 30 seconds until completely deflated. Aortic flow rate and proximal mean arterial pressure (MAP) were measured continuously over the period of balloon deflation. Graded balloon deflation resulted in variable initial return of aortic flow (median, 78 seconds; interquartile range [IQR], 68-105 seconds). A rapid increase in aortic flow during a single-balloon deflation step was observed in all animals (median, 819 mL/min; IQR, 664-1241 mL/min) and corresponded with an immediate decrease in proximal MAP (median, 30 mm Hg; IQR, 14.5-37 mm Hg). Total balloon volume and time to return of flow demonstrated no correlation (r = 0.016). This study is the first to characterize aortic flow during balloon deflation following REBOA. A steep inflection point occurs during balloon deflation that results in an abrupt increase in aortic flow and a concomitant decrease in MAP. Furthermore, the onset of distal aortic flow was inconsistent across study animals and did not correlate with initial balloon volume or relative deflation volume. Future studies to define the factors that affect aortic flow during balloon deflation are needed to facilitate controlled reperfusion following REBOA.
Wire-reinforced endotracheal tube fire during tracheostomy -A case report-.
Shin, Young Duck; Lim, Seung-Woon; Bae, Jin Ho; Yim, Kyoung Hoon; Sim, Jae Hwan; Kwon, Eun Jung
2012-08-01
Every operation could have a fire emergency, especially in the case of a tracheostomy. When a flammable gas meets a source of heat, the danger of fire is remarkable. A tracheal tube filled with a high concentration of oxygen is also a great risk factor for fire. Intra-tracheal tube fire is a rare, yet critical emergency with catastrophic consequences. Thus, numerous precautions are taken during a tracheostomy like, use of a special tube to prevent laser damage, ballooning of the tube with normal saline instead of air, and dilution of FiO(2) with helium or nitrogen. Since the first recorded cases on tube fires, most of the fires were initiated in the balloon and the tip. In the present case report, however, we came across a fire incidence, which originated from the wire.
Wire-reinforced endotracheal tube fire during tracheostomy -A case report-
Shin, Young Duck; Bae, Jin Ho; Yim, Kyoung Hoon; Sim, Jae Hwan; Kwon, Eun Jung
2012-01-01
Every operation could have a fire emergency, especially in the case of a tracheostomy. When a flammable gas meets a source of heat, the danger of fire is remarkable. A tracheal tube filled with a high concentration of oxygen is also a great risk factor for fire. Intra-tracheal tube fire is a rare, yet critical emergency with catastrophic consequences. Thus, numerous precautions are taken during a tracheostomy like, use of a special tube to prevent laser damage, ballooning of the tube with normal saline instead of air, and dilution of FiO2 with helium or nitrogen. Since the first recorded cases on tube fires, most of the fires were initiated in the balloon and the tip. In the present case report, however, we came across a fire incidence, which originated from the wire. PMID:22949984
Mobile, high-wind, balloon-launching apparatus
NASA Technical Reports Server (NTRS)
Rust, W. David; Marshall, Thomas C.
1989-01-01
In order to place instruments for measuring meteorological and electrical parameters into thunderstorms, an inexpensive apparatus has been developed which makes it possible to inflate, transport, and launch balloons in high winds. The launching apparatus is a cylinder of bubble plastic that is made by joining the sides of the cylinder together with a velcro rip strip. A balloon is launched by pulling the rip strip rapidly. This allows the balloon to pop upward into the ambient low-level wind and carry its instrumentation aloft. Different-sized launch tubes are constructed to accommodate particular sizes of balloons. Balloons have been launched in winds of about 20 m/s.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Woong Hee; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Park, Jung-Hun
Purpose: Little was known about the safety and long-term efficacy of fluoroscopically guided balloon dilation for postintubation tracheal stenosis. The purpose of this study was to evaluate the safety and long-term efficacy of fluoroscopically guided balloon dilation in patients with postintubation tracheal stenosis. Methods: From February 2000 to November 2010, 14 patients underwent fluoroscopically guided balloon dilation for postintubation tracheal stenosis. Technical success, clinical success, and complications were evaluated. Patients were followed up for recurrent symptoms. Results: In all patients, fluoroscopically guided balloon dilation was technically and clinically successful with no major complications. Following the initial procedure, six patients (43more » %) remained asymptomatic during a follow-up period. Obstructive symptoms recurred in eight patients (57 %) within 6 months (mean, 1.7 months), who were treated with repeat balloon dilation (n = 4) and other therapies. Of the four patients who underwent repeat balloon dilation, three became asymptomatic. One patient became asymptomatic after a third balloon dilation. On long-term (mean, 74 months) follow-up, 71 % of patients experienced relief of symptoms following fluoroscopically guided balloon dilation. Conclusions: Fluoroscopically guided balloon dilation may be safe, is easy to perform, and resulted in effective treatment in patients with postintubation tracheal stenosis.« less
Technologies developed by CNES balloon team
NASA Astrophysics Data System (ADS)
Sosa-Sesma, Sergio; Charbonnier, Jean-Marc; Deramecourt, Arnaud
CNES balloon team develops and operates all the components of this kind of vehicle: it means envelope and gondola. This abstract will point out only developments done for envelope. Nowadays CNES offers to scientists four types of envelops that cover a large range of mission demands. These envelops are: 1. Zero pressure balloons: Size going from 3,000m3 to 600,000m3, this kind of envelop is ideal for short duration flights (a few hours) but if we use an intelligent management of ballast consumption and if we chose the best launch site, it is possible to perform medium duration flights (10/20 days depending on the ballast on board). Flight train mass starts at 50kg for small balloons and reach 1000kg for larger ones. Zero pressure balloons are inflated with helium gas. 2. Super pressure balloons: Diameter going from 2.5m to 12m, this kind of envelop is ideal for long duration flights (1 to 6 months). Flight train is inside the envelop for small balloons, it means 2.5 diameter meters which is usually called BPCL (Super pressure balloon for Earth boundary layer) and it is about 3kg of mass. Larger ones could lift external flight trains about 50kg of mass. Super pressure balloons are inflated with helium gas. 3. MIR balloons: Size going from 36,000m3 to 46,000m3. Ceiling is reach with helium gas but after three days helium is no longer present inside and lift force is produced by difference of temperature between air inside and air of atmosphere. Flight trains must not be over 50kg. 4. Aero Clipper balloons: A concept to correlate measurements done in oceans and in nearest layers of atmosphere simultaneously. Flight train is made by a "fish" that drags inside water and an atmospheric gondola few meters above "fish", both pushed by a balloon which profits of the wind force. Materials used for construction and assembling depend on balloon type; they are usually made of polyester or polyethylene. Thickness varies from 12 micrometers to 120 micrometers. Balloon assembling is made at ZODIAC site (near Toulouse) by Zodiac teams although all mechanical machines belong to CNES. These machines had been developed by CNES to cut, to weld and to thermo-joint the different parts of the balloon.
78 FR 9785 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-12
... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... airworthiness directive (AD) for certain Lindstrand Hot Air Balloons Ltd female ACME threaded hose connectors...., Washington, DC 20590. For service information identified in this AD, contact Lindstrand Hot Air Balloons Ltd...
77 FR 64763 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-23
... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... propose to adopt a new airworthiness directive (AD) for certain Lindstrand Hot Air Balloons Ltd female... identified in this proposed AD, contact Lindstrand Hot Air Balloons Ltd., Maesbury Road, Oswestry, Shropshire...
78 FR 18533 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-27
... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... Hot Air Balloons Ltd female ACME threaded hose connectors, part numbers HS6139 and HS6144, installed... follows: * * * * * (c) Applicability This AD applies to Lindstrand Hot Air Balloons Ltd female ACME...
False coronary dissection with the new Monorail angioplasty balloon catheter.
Esplugas, E; Cequier, A R; Sabaté, X; Jara, F
1990-01-01
During percutaneous transluminal coronary angioplasty, the appearance of persistent staining in the vessel by contrast media suggests coronary dissection. We report seven patients in whom a false image of severe coronary dissection was observed during angioplasty performed with the new Monorail balloon catheter. This image emerges at the moment of balloon inflation, is distally located to the balloon, and disappears with balloon catheter deflation. No complications were associated with the appearance of this image.
Status report on the activities of National Balloon Facility at Hyderabad
NASA Astrophysics Data System (ADS)
Shankarnarayan, Sreenivasan; S, Sreenivasan; Shankarnarayan, Sreenivasan; Manchanda, R. K.; Subba Rao Jonnalagadda, Venkata; Buduru, Suneelkumar
National balloon facility at Hyderabad has been mandated to provide launch support for Indian and International scientific balloon experiments and also perform the necessary research and development in the design and fabrication of plastic balloons. In the last 4 years, since our last report, NBF has launched many successful balloon flights for the astronomy payloads and a large number of high altitude GPS Sonde flights at different places in the country. We have also continued our efforts on qualification of raw materials for zero-failure performance of our balloons and major focus on upgrading of various facilities and load-line instrumentation for launching from remote sites. We foresee a surge of balloon based experimental activity for in-situ measurements in atmospheric sciences and concept validation payloads for future space based instruments. A new centre for research in Environmental Sciences and Payload Engineering (ESPE) has also been set up at the National Balloon Facility campus to develop and conduct research in various aspects of Environmental sciences in collaboration with other groups, with a specific goal to identify, development of advanced technologies leading to an improved understanding of the earth system. The Payload Engineering facility is geared to the Design and Fabrication of Micro and Nano Satellites and will act as Inter -University Centre for payload fabrication. In this paper we present an overview of the present and planned activities in scientific ballooning at National Balloon Facility Hyderabad.
Balloon-Inflated Catheters for Enteral Feeding: a Word of Caution.
Dash, Nihar Ranjan; Singh, Anand Narayan; Kilambi, Ragini
2018-02-01
Catheters with inflatable balloons such as a Foley catheter may be used for feeding gastrostomy/jejunostomy. The incorrect or improper use of these catheters can have serious consequences. We report 13 cases of feeding jejunostomy with balloon-inflated catheter's malfunction, some referred to our centre and others operated here over a period of 8 years. The most dramatic consequence of such improper use led to rupture of the small intestine due to inadvertent over-inflation (over 100 ml) of the balloon of the catheter during a contrast study. The patient required a laparotomy with resection and anastomosis of the bowel. Three other patients had similar over-inflation of the balloon leading to severe pain and discomfort. In all three patients, timely deflation of the balloon was sufficient to relieve the symptoms. One patient had intussusception with the inflated balloon acting as a lead point. The patient underwent resection of the small bowel with end jejunostomy and distal mucous fistula. All other patients presented with abdominal pain and distension and intestinal obstruction and were managed non-operatively with deflation of balloon either by aspiration, cutting the balloon port or ultrasound-guided puncture of balloon. Healthcare personnel dealing with patients with indwelling catheters must be educated to suspect, detect and manage such problems. The best measure for such unusual complications of otherwise safe devices would be prevention by training and generation of awareness.
Shafi, Nabil A; Singh, Gagan D; Smith, Thomas W; Rogers, Jason H
2018-05-01
To describe a novel balloon sizing technique used during adult transcatheter patent ductus arteriosus (PDA) closure. In addition, to determine the clinical and procedural outcomes in six patients who underwent PDA balloon sizing with subsequent deployment of a PDA occluder device. Transcatheter PDA closure in adults has excellent safety and procedural outcomes. However, PDA sizing in adults can be challenging due to variable defect size, high flow state, or anatomical complexity. We describe a series of six cases where the balloon- pull through technique was successfully performed for PDA sizing prior to transcatheter closure. Consecutive adult patients undergoing adult PDA closure at our institution were studied retrospectively. A partially inflated sizing balloon was pulled through the defect from the aorta into the pulmonary artery and the balloon waist diameter was measured. Procedural success and clinical outcomes were obtained. Six adult patients underwent successful balloon pull-through technique for PDA sizing during transcatheter PDA closure, since conventional angiography often gave suboptimal opacification of the defect. All PDAs were treated with closure devices based on balloon PDA sizing with complete closure and no complications. In three patients that underwent preprocedure computed tomography, the balloon size matched the CT derived measurements. The balloon pull-through technique for PDA sizing is a safe and accurate sizing modality in adults undergoing transcatheter PDA closure. © 2017 Wiley Periodicals, Inc.
Optimum designs for superpressure balloons
NASA Astrophysics Data System (ADS)
Smith, M. S.; Rainwater, E. L.
2004-01-01
The elastica shape is now well known to be the best basic shape for superpressure balloon design. This shape, also known as the pumpkin, or natural shape for balloons, has been well understood since the early 1900s when it was applied to the determination of the shape of descending parachutes. The elastica shape was also investigated in the 1950s when high strength films were used to produce superpressure cylinder balloons. The need for uniform stress distribution in shells of early superpressure balloons led to a long period of the development of spherical superpressure balloons. Not until the late 1970s was the elastica shape revisited for the purpose of the producing superpressure balloons. This paper will review various development efforts in the field of superpressure design and will elaborate on the current state-of-the-art with suggestions for future developments.
Werner, D; Behrend, D; Schmitz, K P; Urbaszek, W
1995-05-01
Seventy-six PTCA-balloons after coronary angioplasty were studied for superficial changes using scanning electron microscopy (SEM) after fixing in glutardialdehyde. Coronary plaque particles were identified on the balloon surface in 52 cases (68%). Twelve new and unused balloons were subjected to the same chemical treatment and SEM showed no imprints. The average length of the longest imprinted plaques was 128 +/- 201 microns and the average number of plaque particles per balloon was 4.9 +/- 2.7. The maximal dilatation pressure and the number of dilatations showed no influence on the impregnation of plaque particles. However, longer plaque imprints tended to occur under low dilatation pressure. Imprints of plaque particles were significantly higher in patients with low cholesterol (p = 0.0001) and low triglycerides (p = 0.0016). No correlation was seen between imprint length and lipid levels. Similarly, the different balloon materials (polyethylene, polyolefincopolymer) showed no significant differences with regard to plaque occurrence. The PTCA-balloons, plaque particles and six coronary plaques obtained after endatherectomy were subjected to energy dispersive x-ray analysis (EDX) under SEM as EDX reveals qualitative and quantitative information about the structural elements. Highly significant differences in calcium, sodium, phosphorus and silicon contents (p = 0.0000) between plaque particles and balloon surface were observed, owing to the absence of these in balloon material. Thus EDX offers additional advantages over SEM in that it clearly differentiates deformed balloon surface, plaque particle, and retained contrast medium. Plaque particles can be recovered from balloon surfaces after PTCA. Depending upon their size, they could lead to coronary spasm or microembolic phenomenon.
Spiotta, Alejandro M; Miranpuri, Amrendra S; Vargas, Jan; Magarick, Jordan; Turner, Raymond D; Turk, Aquilla S; Chaudry, M Imran
2014-09-01
Endovascular embolization for tumors and vascular malformations has emerged as an important preoperative adjunct prior to resection. We describe the advantages of utilizing a recently released dual lumen balloon catheter for ethylene vinyl alcohol copolymer, also known as Onyx (ev3, Irvine, California, USA), embolization for a variety of head and neck pathologies. A retrospective review of all cases utilizing the Scepter C balloon catheter (MicroVention Inc, Tustin, California, USA) for use in balloon augmented embolization was performed over a 4 month period from October 2012 to February 2013 at the Medical University of South Carolina, Charleston, South Carolina, USA. Charts and angiographic images were reviewed. Representative cases involving diverse pathologies are summarized and illustrate the observed advantages of balloon augmented Onyx embolization with a dual lumen balloon catheter. Balloon augmented Onyx embolization utilizing a novel dual lumen balloon catheter was employed to treat both ruptured and unruptured arteriovenous malformations, intracranial dural arteriovenous fistulae, intracranial neoplasms, carotid body tumors, a thyroid mass, and an extracranial arteriovenous fistula. The dual lumen balloon catheter has several advantages for use with Onyx embolization over older devices, including more efficient proximal plug formation and enhanced navigability for placement deep within the pedicles. The balloon augmented Onyx embolization technique represents a valuable tool to add to the armamentarium of the neurointerventionalist to address a variety of head and neck lesions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
New concepts for interplanetary balloons and blimps, particularly for Titan
NASA Astrophysics Data System (ADS)
Nott, J.
This paper proposes novel approaches for balloons for planets Titan BALLUTE A balloon or blimp arriving at a planet or moon with an atmosphere might inflate falling under a parachute or after landing Neither is ideal In both cases the envelope must include qualities needed for inflation as well as those for flight A ballute BALLoon parachUTE could be used thus a ballute is like a hot air balloon with a large mouth Initially it fills by ram pressure descending through an atmosphere As proposed it would then be heated by solid propellant It would stop descending and float level with hot air lift It is now a perfect location for inflation without wind or movement through the atmosphere and away from the uncertainties of the surface A ballute could be used over several bodies in the solar system BALLOONS FOR LOW TEMPERATURES Flight in very low temperatures is also discussed Conditions are so different that it is useful to examine basic factors These apply for any planet with low temperature and weather calm enough for balloons or blimps First for terrestrial hot air balloons thermal radiation is usually the dominant way heat is lost But radiation rises with the 4th power of absolute temperature At Titan radiation will be one or two orders of magnitude smaller Also the dense atmosphere allows small balloons small temperature differences So convection is small It appears a hot air balloon can easily be heated by a radioactive source likely carried to make electricity Pinholes are not important in such a balloon
Hot-Air Balloon Tours: Crash Epidemiology in the United States, 2000-2011
Ballard, Sarah-Blythe; Beaty, Leland P.; Baker, Susan P.
2016-01-01
Introduction Hot-air balloon tours are FAR Part 91-governed balloon rides conducted for compensation or hire. Part 91, General Aviation, in general involves the least strict federal regulations and accounts for the majority of aviation crashes and fatalities. Methods National Transportation Safety Board reports of hot-air balloon tour crashes in the United States from 2000 through 2011 were read and analyzed. Results During the 12-yr period, 78 hot-air balloon tours crashed, involving 518 occupants. There were 91 serious injuries and 5 fatalities; 83% of crashes resulted in one or more serious or fatal outcomes. Of the serious injuries characterized, 56% were lower extremity fractures. Most crashes (81%) occurred during landing; 65% involved hard landings. Fixed object collisions contributed to 50% of serious injuries and all 5 fatalities. During landing sequences, gondola dragging, tipping, bouncing, and occupant ejection were associated with poor outcomes. Of the crashes resulting in serious or fatal outcomes, 20% of balloons were significantly damaged or destroyed. Discussion The incidence of morbidity and mortality is high among hot-air balloon tour crashes, and the proportion of balloon crashes attributed to paid rides appears to have increased over time. In addition to examining the role of restraint systems, personal protective equipment, and power line emergency procedures in ballooning, injury prevention efforts should target factors such hard landings, object strikes, gondola instability, and occupant ejections, which are associated with balloon injuries and deaths. Crash outcomes may also improve with vehicle engineering that enables balloons themselves to absorb impact forces. PMID:24279231
NASA Astrophysics Data System (ADS)
Chaabane, Makram; Chaabane, Makram; Dalverny, Olivier; Deramecourt, Arnaud; Mistou, Sébastien
The super-pressure balloons developed by CNES are a great challenge in scientific ballooning. Whatever the balloon type considered (spherical, pumpkin...), it is necessary to have good knowledge of the mechanical behavior of the envelope regarding to the flight level and the lifespan of the balloon. It appears during the working stages of the super pressure balloons that these last can exploded prematurely in the course of the first hours of flight. For this reason CNES and LGP are carrying out research programs about experimentations and modelling in order to predict a good stability of the balloons flight and guarantee a life time in adequacy with the technical requirement. This study deals with multilayered polymeric film damage which induce balloons failure. These experimental and numerical study aims, are a better understanding and predicting of the damage mechanisms bringing the premature explosion of balloons. The following damages phenomena have different origins. The firsts are simple and triple wrinkles owed during the process and the stocking stages of the balloons. The second damage phenomenon is associated to the creep of the polymeric film during the flight of the balloon. The first experimental results we present in this paper, concern the mechanical characterization of three different damage phenomena. The severe damage induced by the wrinkles of the film involves a significant loss of mechanical properties. In a second part the theoretical study, concerns the choice and the development of a non linear viscoelastic coupled damage behavior model in a finite element code.
Reduction of prostate intrafraction motion using gas-release rectal balloons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su Zhong; Zhao Tianyu; Li Zuofeng
2012-10-15
Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated withmore » the van Herk formula of 2.5{Sigma}+ 0.7{sigma} to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior-inferior (SI) and anterior-posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left-right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.« less
Indwelling esophageal balloon catheter for benign esophageal stenosis in infants and children.
van der Zee, David; Hulsker, Caroline
2014-04-01
Balloon dilatation of benign esophageal strictures is an established mode of therapy in adults and children. There remains a group of patients with refractory stenosis despite dilatation at regular intervals. An indwelling balloon catheter may offer an alternative. This is a retrospective study of 19 children who underwent esophagoscopy between 2004 and 2012 with placement of an indwelling balloon catheter for refractory esophageal stenosis. Total number of endoscopies, number of endoscopies with indwelling balloon catheter, as well as complications, reoperations, and mortality due to use of the balloon catheter were studied. Patient age ranged from 4 weeks to 15 years. The indwelling balloon catheter was used to treat refractory stenosis after corrective surgery of long gap esophageal atresia (n = 5), esophageal atresia with distal fistula (n = 2), refractory esophageal stenosis due to caustic esophageal burns (n = 7), reflux (n = 2), and stenosis of unknown cause (n = 3). With the indwelling balloon catheter in place, the mean number of endoscopies equalled four. Complications were restenosis after a symptom-free period for which a new indwelling balloon catheter was necessary (n = 3). Two others needed two to five additional dilations: balloon leakage requiring replacement (n = 7 in 5 patients), sputum retention (n = 1), and dislodgement (n = 5 in 4 patients). More importantly, there was no mortality or the need for any patient to undergo a surgical resection. The indwelling balloon catheter is safe to use and can be used by parents at home. More importantly it obviates the need for rethoracotomy/-scopy or esophageal replacement.
Hardell, Lennart; Carlberg, Michael; Hansson Mild, Kjell
2006-09-01
To study the use of cellular and cordless telephones and the risk for malignant brain tumours. Two case-control studies on malignant brain tumours diagnosed during 1997-2003 included answers from 905 (90%) cases and 2,162 (89%) controls aged 20-80 years. We present pooled analysis of the results in the two studies. Cumulative lifetime use for >2,000 h yielded for analogue cellular phones odds ratio (OR)=5.9, 95% confidence interval (CI)=2.5-14, digital cellular phones OR=3.7, 95% CI=1.7-7.7, and for cordless phones OR=2.3, 95% CI=1.5-3.6. Ipsilateral exposure increased the risk for malignant brain tumours; analogue OR=2.1, 95% CI=1.5-2.9, digital OR=1.8, 95% CI=1.4-2.4, and cordless OR=1.7, 95% CI=1.3-2.2. For high-grade astrocytoma using >10 year latency period analogue phones yielded OR=2.7, 95% CI=1.8-4.2, digital phones OR=3.8, 95% CI=1.8-8.1, and cordless phones OR=2.2, 95% CI=1.3-3.9. In the multivariate analysis all phone types increased the risk. Regarding digital phones OR=3.7, 95% CI=1.5-9.1 and cordless phones OR=2.1, 95% CI=0.97-4.6 were calculated for malignant brain tumours for subjects with first use use <20 years of age, higher than in older persons. Increased risk was obtained for both cellular and cordless phones, highest in the group with >10 years latency period.
NASA Astrophysics Data System (ADS)
Voss, P. B.; Nott, J.; Cutts, J. A.; Hall, J. L.; Beauchamp, P. M.; Limaye, S. S.; Baines, K. H.; Hole, L. R.
2013-12-01
In situ exploration of the upper atmosphere of Venus, approximately 65-77 km altitude, could answer many important questions (Limaye 2013, Crisp 2013). This region contains a time-variable UV absorber of unknown composition that controls many aspects of the heat balance on Venus. Understanding the composition and dynamics of this unknown absorber is an important science goal; in situ optical and chemical measurements are needed. However, conventional approaches do not provide access to this altitude range, repeated traverses, and a mission lifetime of several months needed to effectively carry out the science. This paper examines concepts for altitude-controlled balloons not previously flown on planetary missions that could potentially provide the desired measurements. The concepts take advantage of the fact that at 60 km altitude, for example, the atmospheric density on Venus is about 40% of the sea-level density on earth and the temperature is a moderate 230 K. The solar flux is approximately double that on earth, creating some thermal challenges, but making photovoltaic power highly effective. Using a steady-state thermodynamic model and flight data from Earth, we evaluate the suitability of two types of altitude-controlled balloons for a potential mission on Venus. Such balloons could repeatedly measure profiles, avoid diurnal temperature extremes, and navigate using wind shear. The first balloon design uses air ballast (AB) whereby ambient air can be compressed into or released from a constant-volume balloon, causing it to descend or ascend accordingly. The second design uses lift-gas compression (LGC) to change the volume of a zero-pressure balloon, thereby changing its effective density and altitude. For an altitude range of 60-75 km on Venus, we find that the superpressure volume for a LGC balloon is about 5% of that needed for an AB balloon while the maximum pressurization is the same for both systems. The compressor work per km descent of the LGC balloon is about 10% of the AB balloon, largely due to the much lower flow rate. The LGC balloon must compress some lift gas at sunrise, but this can be managed by one of several strategies. We conclude that while the weight constraints are likely to be significant, LGC altitude-controlled balloons may be feasible for accessing the 60 to 75 km altitude range on Venus. The underlying concept of balloons on Venus was proven by the Soviet Union's successful deployment of their two superpressure VEGA balloons in 1981 operating at a fixed altitude near 55 km. Superpressure balloon concepts for similar altitudes and larger payloads have since been proposed for NASA's Discovery program and ESA's Cosmic Visions program. The LGC balloon would add a zero-pressure envelope and a compressor to the established superpressure design, allowing it to ascend above the deployment altitude and realize lossless altitude control over a range of several scale heights. The thermodynamic equations, flight data, and conceptual analysis presented are intended to foster further discussion about the feasibility and potential benefits of a balloon mission to Venus.
14 CFR 61.115 - Balloon rating: Limitations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... takes a practical test in a balloon with an airborne heater: (1) The pilot certificate will contain a limitation restricting the exercise of the privileges of that certificate to a balloon with an airborne... removed when the person obtains the required aeronautical experience in a balloon with an airborne heater...
21 CFR 884.5050 - Metreurynter-balloon abortion system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...
14 CFR 31.49 - Control systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
.... (c) Each balloon using a captive gas as the lifting means must have an automatic valve or appendix... STANDARDS: MANNED FREE BALLOONS Design Construction § 31.49 Control systems. (a) Each control must operate... minute when the balloon is at its maximum operating pressure. (d) Each hot air balloon must have a means...
14 CFR 31.49 - Control systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
.... (c) Each balloon using a captive gas as the lifting means must have an automatic valve or appendix... STANDARDS: MANNED FREE BALLOONS Design Construction § 31.49 Control systems. (a) Each control must operate... minute when the balloon is at its maximum operating pressure. (d) Each hot air balloon must have a means...
14 CFR 31.49 - Control systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... (c) Each balloon using a captive gas as the lifting means must have an automatic valve or appendix... STANDARDS: MANNED FREE BALLOONS Design Construction § 31.49 Control systems. (a) Each control must operate... minute when the balloon is at its maximum operating pressure. (d) Each hot air balloon must have a means...
14 CFR 31.49 - Control systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
.... (c) Each balloon using a captive gas as the lifting means must have an automatic valve or appendix... STANDARDS: MANNED FREE BALLOONS Design Construction § 31.49 Control systems. (a) Each control must operate... minute when the balloon is at its maximum operating pressure. (d) Each hot air balloon must have a means...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-31
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-865] Certain Balloon Dissection Devices... the United States after importation of certain dissection balloons and products containing the same by... importation of certain dissection balloons and products containing the same that infringe one or more of...
21 CFR 884.5050 - Metreurynter-balloon abortion system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...
21 CFR 884.5050 - Metreurynter-balloon abortion system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...
21 CFR 884.5050 - Metreurynter-balloon abortion system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...
21 CFR 884.5050 - Metreurynter-balloon abortion system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...
14 CFR 61.3 - Requirement for certificates, ratings, and authorizations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... with a glider category rating, a balloon class rating, or glider or balloon privileges; (ii) Is... than glider or balloon privileges and holds a U.S. driver's license; (iii) Is exercising the privileges... exercising the privileges of a sport pilot certificate with glider or balloon privileges; (v) Is exercising...
14 CFR 61.3 - Requirement for certificates, ratings, and authorizations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... with a glider category rating, a balloon class rating, or glider or balloon privileges; (ii) Is... than glider or balloon privileges and holds a U.S. driver's license; (iii) Is exercising the privileges... exercising the privileges of a sport pilot certificate with glider or balloon privileges; (v) Is exercising...
14 CFR 61.3 - Requirement for certificates, ratings, and authorizations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... with a glider category rating, a balloon class rating, or glider or balloon privileges; (ii) Is... than glider or balloon privileges and holds a U.S. driver's license; (iii) Is exercising the privileges... exercising the privileges of a sport pilot certificate with glider or balloon privileges; (v) Is exercising...
MAPLE: reflected light from exoplanets with a 50-cm diameter stratospheric balloon telescope
NASA Astrophysics Data System (ADS)
Marois, Christian; Bradley, Colin; Pazder, John; Nash, Reston; Metchev, Stanimir; Grandmont, Frédéric; Maire, Anne-Lise; Belikov, Ruslan; Macintosh, Bruce; Currie, Thayne; Galicher, Raphaël.; Marchis, Franck; Mawet, Dimitri; Serabyn, Eugene; Steinbring, Eric
2014-08-01
Detecting light reflected from exoplanets by direct imaging is the next major milestone in the search for, and characterization of, an Earth twin. Due to the high-risk and cost associated with satellites and limitations imposed by the atmosphere for ground-based instruments, we propose a bottom-up approach to reach that ultimate goal with an endeavor named MAPLE. MAPLE first project is a stratospheric balloon experiment called MAPLE-50. MAPLE-50 consists of a 50 cm diameter off-axis telescope working in the near-UV. The advantages of the near-UV are a small inner working angle and an improved contrast for blue planets. Along with the sophisticated tracking system to mitigate balloon pointing errors, MAPLE-50 will have a deformable mirror, a vortex coronograph, and a self-coherent camera as a focal plane wavefront-sensor which employs an Electron Multiplying CCD (EMCCD) as the science detector. The EMCCD will allow photon counting at kHz rates, thereby closely tracking telescope and instrument-bench-induced aberrations as they evolve with time. In addition, the EMCCD will acquire the science data with almost no read noise penalty. To mitigate risk and lower costs, MAPLE-50 will at first have a single optical channel with a minimum of moving parts. The goal is to reach a few times 109 contrast in 25 h worth of flying time, allowing direct detection of Jovians around the nearest stars. Once the 50 cm infrastructure has been validated, the telescope diameter will then be increased to a 1.5 m diameter (MAPLE-150) to reach 1010 contrast and have the capability to image another Earth.
Fullerton, Birgit; Siebenhofer, Andrea; Jeitler, Klaus; Horvath, Karl; Semlitsch, Thomas; Berghold, Andrea; Plank, Johannes; Pieber, Thomas R; Gerlach, Ferdinand M
2016-06-30
Short-acting insulin analogue use for people with diabetes is still controversial, as reflected in many scientific debates. To assess the effects of short-acting insulin analogues versus regular human insulin in adults with type 1 diabetes. We carried out the electronic searches through Ovid simultaneously searching the following databases: Ovid MEDLINE(R), Ovid MEDLINE(R) In-Process & Other Non-Indexed Citations, Ovid MEDLINE(R) Daily and Ovid OLDMEDLINE(R) (1946 to 14 April 2015), EMBASE (1988 to 2015, week 15), the Cochrane Central Register of Controlled Trials (CENTRAL; March 2015), ClinicalTrials.gov and the European (EU) Clinical Trials register (both March 2015). We included all randomised controlled trials with an intervention duration of at least 24 weeks that compared short-acting insulin analogues with regular human insulins in the treatment of adults with type 1 diabetes who were not pregnant. Two review authors independently extracted data and assessed trials for risk of bias, and resolved differences by consensus. We graded overall study quality using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) instrument. We used random-effects models for the main analyses and presented the results as odds ratios (OR) with 95% confidence intervals (CI) for dichotomous outcomes. We identified nine trials that fulfilled the inclusion criteria including 2693 participants. The duration of interventions ranged from 24 to 52 weeks with a mean of about 37 weeks. The participants showed some diversity, mainly with regard to diabetes duration and inclusion/exclusion criteria. The majority of the trials were carried out in the 1990s and participants were recruited from Europe, North America, Africa and Asia. None of the trials was carried out in a blinded manner so that the risk of performance bias, especially for subjective outcomes such as hypoglycaemia, was present in all of the trials. Furthermore, several trials showed inconsistencies in the reporting of methods and results.The mean difference (MD) in glycosylated haemoglobin A1c (HbA1c) was -0.15% (95% CI -0.2% to -0.1%; P value < 0.00001; 2608 participants; 9 trials; low quality evidence) in favour of insulin analogues. The comparison of the risk of severe hypoglycaemia between the two treatment groups showed an OR of 0.89 (95% CI 0.71 to 1.12; P value = 0.31; 2459 participants; 7 trials; very low quality evidence). For overall hypoglycaemia, also taking into account mild forms of hypoglycaemia, the data were generally of low quality, but also did not indicate substantial group differences. Regarding nocturnal severe hypoglycaemic episodes, two trials reported statistically significant effects in favour of the insulin analogue, insulin aspart. However, due to inconsistent reporting in publications and trial reports, the validity of the result remains questionable.We also found no clear evidence for a substantial effect of insulin analogues on health-related quality of life. However, there were few results only based on subgroups of the trial populations. None of the trials reported substantial effects regarding weight gain or any other adverse events. No trial was designed to investigate possible long-term effects (such as all-cause mortality, diabetic complications), in particular in people with diabetes related complications. Our analysis suggests only a minor benefit of short-acting insulin analogues on blood glucose control in people with type 1 diabetes. To make conclusions about the effect of short acting insulin analogues on long-term patient-relevant outcomes, long-term efficacy and safety data are needed.
Deppe, Antje-Christin; Weber, Carolyn; Liakopoulos, Oliver J; Zeriouh, Mohamed; Slottosch, Ingo; Scherner, Maximilian; Kuhn, Elmar W; Choi, Yeong-Hoon; Wahlers, Thorsten
2017-03-01
Prophylactic intra-aortic balloon pump (IABP) support for high-risk patients before coronary artery bypass grafting (CABG) is controversial. This meta-analysis sought to determine the current role of preoperative IABP support. We performed a meta-analysis of randomized (RCT) and observational trials (OT) that fulfilled the following criteria: (1) Group comparison of patients with prophylactic IABP implantation before CABG with a control group; (2) reporting at least one desired clinical endpoint, including all-cause mortality, myocardial infarction, cerebrovascular accident (CVA), and renal failure. Pooled treatment effects (odds ratio [OR] or weighted mean difference, and 95% confidence intervals [95%CI]) were assessed using a fixed or random effects model. A total of 9,212 patients from 23 studies (7 RCT, 16 OT) were identified after a literature search of major databases using a predefined keyword list. Absolute risk reduction for mortality in RCTs was 4.4% (OR 0.43; 95%CI 0.25-0.73; p = 0.0025). Prophylactic IABP use before CABG surgery also decreased the risk for myocardial infarction (OR 0.58; 95%CI 0.43-0.78; p = 0.004), CVA (OR 0.67; 95%CI 0.47-0.97; p = 0.042), and renal failure (OR 0.62; 95%CI 0.47-0.83; p = 0.0014). Length of intensive care unit stay (p < 0.0001) and length of hospital stay (p < 0.0001) were significantly reduced in patients with preoperative IABP use. Current evidence from RCT and OT suggests beneficial effects for the IABP in high-risk patients before CABG surgery. © 2017 Wiley Periodicals, Inc.
Curtis, Jeptha P; Rathore, Saif S; Wang, Yongfei; Chen, Jersey; Nallamothu, Brahmajee K; Krumholz, Harlan M
2012-01-01
Intra-aortic balloon pumps (IABP) frequently are used to provide hemodynamic support during high risk percutaneous coronary intervention (PCI), but clinical evidence to support their use is mixed. We examined hospital variation in IABP use among high risk PCI patients, and determined the association of IABP use on mortality in this population. We analyzed data submitted to the CathPCI Registry between January 2005 and December 2007. High risk PCI was defined as having at least 1 of the following features: unprotected left main artery as the target vessel, cardiogenic shock, severely depressed left ventricular function, or ST segment elevation myocardial infarction. Hospitals were categorized into quartiles by their proportional use of IABP. We examined differences in in-hospital mortality across hospital quartiles using a hierarchical logistic regression model to adjust for differences in patient and hospital characteristics across hospital quartiles of IABP use. IABPs were used in 18,990 (10.5%) of 181,599 high risk PCIs. Proportional use of IABP varied significantly across hospital quartiles: Q1, 0.0 to 6.5%; Q2, 6.6 to 9.2%; Q3, 9.3 to 14.1%; Q4, 14.2 to 40.0%. In multivariable analysis, after adjustment for differences in patient and hospital characteristics, in-hospital mortality was comparable across quartiles of hospital IABP usage (Q1, Ref; Q2, odds ratio 1.11, 95% CI 0.99-1.24; Q3, OR 1.03, 95% CI 0.92-1.15; Q4, OR 1.06, 95% CI 0.94-1.18). IABP use varied significantly across hospitals for high risk PCI. However, this variation in IABP use was not associated with differences in in-hospital mortality.
Small bowel biopsy; Push enteroscopy; Double-balloon enteroscopy; Capsule enteroscopy ... into the upper gastrointestinal tract. During a double-balloon enteroscopy, balloons attached to the endoscope can be ...
Balloon concepts for scientific investigation of Mars and Jupiter
NASA Technical Reports Server (NTRS)
Ash, R. L.
1979-01-01
Opportunities for scientific investigation of the atmospheric planets using buoyant balloons have been explored. Mars and Jupiter were considered in this study because design requirements at those planets bracket nominally the requirements at Venus, and plans are already underway for a joint Russian-French balloon system at Venus. Viking data has provided quantitative information for definition of specific balloon systems at Mars. Free flying balloons appear capable of providing valuable scientific support for more sophisticated Martian surface probes, but tethered and powered aerostats are not attractive. The Jovian environment is so extreme, hot atmosphere balloons may be the only scientific platforms capable of extended operations there. However, the estimated system mass and thermal energy required are very large.
Ozone profiles from tethered balloon measurements in an urban plume experiment
NASA Technical Reports Server (NTRS)
Youngbluth, O., Jr.; Storey, R. W.; Clendenin, C. G.; Jones, S.; Leighty, B.
1981-01-01
NASA Langley Research Center used two tethered balloon systems to measure ozone in the general area of Norfolk, Va. The large balloon system which has an altitude range of 1,500 meters was located at Wallops Island, Va., and the smaller balloon which has an altitude range of 900 meters was located at Chesapeake, Va. Each balloon system measured ozone, temperature, humidity, wind speed, and wind direction from ground to its maximum altitude. From these measurements and from the location of the balloon sites, areas of ozone generation and ozone transport may be inferred. The measurements which were taken during August 1979 are discussed as well as the measurement techniques.
Low-Altitude Exploration of the Venus Atmosphere by Balloon
NASA Technical Reports Server (NTRS)
Landis, Geoffrey A.
2010-01-01
The planet Venus represents an exciting target for future exploration by spacecraft. One target of scientific interest is the lower atmosphere, which represents an environment of high temperature and moderate to high atmospheric pressure. This represents a considerable challenge to the technical art of ballooning, but one which may be amenable to solution. Several possible designs for low-altitude balloons are discussed. Conceptual design for three mission examples are analyzed: a conventional balloon operating below the cloud level at an altitude of 25 kilometers, a large rigid-envelope balloon operating near the surface at an altitude of 5 kilometers, and a small, technology demonstrator rigid-envelope balloon operating at 5 kilometers.
[Pressure-volume recording of PTCA catheters with balloons of lower and higher compliance].
Werner, C; Bloss, P; Kiessling, D; Patzschke, H; Unverdorben, M; Vallbracht, C
1999-11-01
In this report, the results of complementary studies of pressure-volume (p-V) measurements on balloon catheters with balloons of low (LC) and high compliance (HC) used for percutaneous transluminal coronary angioplasty are discussed. The measurements were performed with balloons unconfined in air (free dilatation) and also confined in different shells. In the case of rigid shells, a surprisingly high self-expansion of the catheters was found. Although this self-expansion does not contribute to the radial dilatation, it cannot be neglected, but must be taken into account when the success of balloon dilatation is determined on the basis of measured p-V curves. The investigations performed using wrapped shells clearly show the different dilatation properties of LC and HC balloons. The results provide important information on the feasibility of controlled balloon dilatation on the basis of p-V measurements performed on-line during PTCA.
Wind-Tunnel Investigation of a Balloon as a Towed Decelerator at Mach Numbers from 1.47 to 2.50
NASA Technical Reports Server (NTRS)
McShera, John T.; Keyes, J. Wayne
1961-01-01
A wind-tunnel investigation has been conducted to study the characteristics of a towed spherical balloon as a drag device at Mach numbers from 1.47 to 2.50, Reynolds numbers from 0.36 x 10(exp 6) to 1.0 x 10(exp 6) , and angles of attack from -15 to 15 deg. Towed spherical balloons were found to be stable at supersonic speeds. The drag coefficient of the balloon is reduced by the presence of a tow cable and a further reduction occurs with the addition of a payload. The balloon inflation pressure required to maintain an almost spherical shape is about equal to the free-stream dynamic pressure. Measured pressure and temperature distribution around the balloon alone were in fair agreement with predicted values. There was a pronounced decrease in the pressure coefficients on the balloon when attached to a tow cable behind a payload.
Advances in endoscopic balloon therapy for weight loss and its limitations
Vyas, Dinesh; Deshpande, Kaivalya; Pandya, Yagnik
2017-01-01
The field of medical and surgical weight loss is undergoing an explosion of new techniques and devices. A lot of these are geared towards endoscopic approaches rather than the conventional and more invasive laparoscopic or open approach. One such recent advance is the introduction of intrgastric balloons. In this article, we discuss the recently Food and Drug Administration approved following balloons for weight loss: the Orbera™ Intragastric Balloon System (Apollo Endosurgery Inc, Austin, TX, United States), the ReShape® Integrated Dual Balloon System (ReShape Medical, Inc., San Clemente, CA, United States), and the Obalon (Obalon® Therapeutics, Inc.). The individual features of each of these balloons, the method of introduction and removal, and the expected weight loss and possible complications are discussed. This review of the various balloons highlights the innovation in the field of weight loss. PMID:29209122
Reed, Larrite; Edriss, Hawa; Nugent, Kenneth
2018-06-01
Obesity in the United States is a medical crisis with many people attempting to lose weight with caloric restriction. Some patients choose minimally invasive weight loss solutions, such as intragastric balloon systems. These balloon systems were approved by the Federal Drug Administration (FDA) in 2015-2016 and have been considered safe, with minimal side effects. We report a patient with a two-day history of melena, abdominal pain, hypotension, and syncope which developed five months after placement of an intragastric balloon. Esophagogastroduodenoscopy with balloon removal revealed a small 8-mm gastric ulcer in the incisura. This gastric ulcer probably developed secondary to mechanical compression of the stomach mucosa by the gastric balloon which contained 900 mL of saline. The FDA is now investigating five deaths since 2016 associated with these second-generation balloons. Clinicians should be aware of these complications when evaluating patients with gastrointestinal complications, such as bleeding.
Elastoplasty: A Silicon Polymer as a New Filling Material for Kyphoplasty in Comparison to PMMA.
Bornemann, Rahel; Rommelspacher, Yorck; Jansen, Tom R; Sander, Kirsten; Wirtz, Dieter C; Pflugmacher, Robert
2016-07-01
Painful vertebral compression fractures (VCF) caused by osteoporosis are a common health problem in the elderly population. If conservative treatments are unsuccessful, surgical treatments like vertebroplasty or kyphoplasty are recommended. But the use of Polymethylmethacrylat (PMMA) bone cement for augmentation surgery is associated with risks. Evaluation of the effectiveness and safety of a newly developed silicon polymer (VK100) that can be used instead of PMMA bone cement for kyphoplasty treatments. A retrospective study of 30 patients comparing the outcomes of kyphoplasty treatments conducted with PMMA and VK100. Clinic for Orthopedics and Trauma Surgery Bonn, Germany. Thirty patients with one to 3 VCF were treated either with balloon kyphoplasty using VK100 or balloon kyphoplasty using PMMA bone cement. Data from both groups was compared by a matched pair analysis. The medial vertebral height was measured at each examination radiologically. The patients stated their pain intensity using the Visual Analogue Scale (VAS) and the patient's functional impairment was evaluated with the Oswestry-Disability-Index (ODI).All data were assessed before surgery, and 3 days, 3 months, 6 months, and 12 months after surgery. Intraoperative and postoperative adverse events were documented. The patients' functional impairment and pain improved significantly after surgery. The course of ODI and VAS was comparable in both treatment groups, but the improvement in the VK group was significantly ongoing until the 12 month follow-up. Vertebral height improvement was significant in both groups, but the PMMA group achieved a better absolute restoration. The vertebral height stayed constant during the follow-up in the VK group and worsened significantly in the PMMA group. There was no significant difference between groups concerning the occurrence of additional fractures; and no other types of complications or surgery-related adverse events were observed in either the PMMA group or in the VK group. The study is only a matched pair analysis of 15 patients for each procedure and the amount of injected filling material was not recorded. The study results demonstrate that the clinical outcome of VAS and ODI of using the silicon polymer VK100 is comparable or slightly better than using PMMA. VK 100 shows a trend to minor additional fractures during the follow-up. However, height restoration is not satisfactory in comparison to PMMA, although vertebral height stayed more or less constant in the VK group. To address the augmentation success further, it would be necessary to study a larger patient group over a longer study period and to assess additional parameters such as bone density and injected amount of filling material.
14 CFR 31.49 - Control systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... minute when the balloon is at its maximum operating pressure. (d) Each hot air balloon must have a means to allow the controlled release of hot air during flight. (e) Each hot air balloon must have a means... STANDARDS: MANNED FREE BALLOONS Design Construction § 31.49 Control systems. (a) Each control must operate...
History and perspectives of scientific ballooning
NASA Astrophysics Data System (ADS)
Lefevre, Frank
2001-08-01
Prehistory: Robertson, Biot and Gay-Lussac; Glaisher and the first studies of the atmosphere; Flammarion. The rebirth of scientific ballooning: polyethylene and mylar vehicles at Minneapolis. Super-pressurized balloons. The CNES and the Nasa programs; meteorology, aeronomy and astronomy, The Eole program. The Venus and Mars balloons in the French-Soviet space program. The future.
21 CFR 870.3535 - Intra-aortic balloon and control system
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Intra-aortic balloon and control system 870.3535... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3535 Intra-aortic balloon and control system (a) Identification. A intra-aortic balloon and control system is a device that...
21 CFR 870.3535 - Intra-aortic balloon and control system
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intra-aortic balloon and control system 870.3535... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3535 Intra-aortic balloon and control system (a) Identification. A intra-aortic balloon and control system is a device that...
14 CFR 61.23 - Medical certificates: Requirement and duration.
Code of Federal Regulations, 2011 CFR
2011-01-01
... pilot certificate with glider or balloon privileges; or (ii) A pilot certificate with a glider category... privileges in a glider or balloon; (3) When exercising the privileges of a pilot certificate with a glider category rating or balloon class rating in a glider or a balloon, as appropriate; (4) When exercising the...
14 CFR 61.23 - Medical certificates: Requirement and duration.
Code of Federal Regulations, 2012 CFR
2012-01-01
... pilot certificate with glider or balloon privileges; or (ii) A pilot certificate with a glider category... privileges in a glider or balloon; (3) When exercising the privileges of a pilot certificate with a glider category rating or balloon class rating in a glider or a balloon, as appropriate; (4) When exercising the...
14 CFR 61.23 - Medical certificates: Requirement and duration.
Code of Federal Regulations, 2013 CFR
2013-01-01
... pilot certificate with glider or balloon privileges; or (ii) A pilot certificate with a glider category... privileges in a glider or balloon; (3) When exercising the privileges of a pilot certificate with a glider category rating or balloon class rating in a glider or a balloon, as appropriate; (4) When exercising the...
14 CFR 61.23 - Medical certificates: Requirement and duration.
Code of Federal Regulations, 2014 CFR
2014-01-01
... pilot certificate with glider or balloon privileges; or (ii) A pilot certificate with a glider category... privileges in a glider or balloon; (3) When exercising the privileges of a pilot certificate with a glider category rating or balloon class rating in a glider or a balloon, as appropriate; (4) When exercising the...
21 CFR 870.3535 - Intra-aortic balloon and control system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... syndrome, cardiac and non-cardiac surgery, or complications of heart failure. The special controls for this... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intra-aortic balloon and control system. 870.3535... balloon and control system. (a) Identification. An intra-aortic balloon and control system is a...
Biliary sphincteroplasty facilitates retrieval of proximally migrated plastic biliary stent.
Shah, Dharmesh K; Jain, Samit S; Somani, Piyush O; Rathi, Pravin M
2014-01-01
Proximal migration of biliary stents presents a technical challenge for the therapeutic endoscopist. It may require multiple, complicated corrective procedures resulting in significant morbidity to the patients. In this study we evaluated the utility of balloon biliary sphincteroplasty with CRE (Controlled Radial Expansion) Balloon Dilator on retrieval of proximally migrated biliary stents. We identified patients from our ERCP database who presented with proximal migration of biliary stent, between August 2011 and October 2013. Patients in whom the stent could not be retrieved with conventional methods, balloon sphincteroplasty was performed with a 12 mm CRETM Balloon Dilator (Boston Scientific). Stent removal was attempted with extraction balloon or basket thereafter. We identified 28 patients with proximal migration of biliary stents, placed for benign diseases of the common bile duct. Stent removal was successful in 18 patients (64.28%) with help of an extraction balloon or basket. Of the remaining 10 patients, balloon sphincteroplasty was successfully followed by stent removal in eight patients. Balloon biliary sphincteroplasty increases the success rate of retrieving proximally migrated biliary stents. The procedure is safe, technically easy and yields a good success rate in our experience.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andersen, Poul Erik; Kjeldsen, Anette D.
2008-05-15
Long-term follow-up results after embolization of 13 pulmonary arteriovenous malformations in 10 patients by use of 14 detachable silicone balloons are given. Patients were followed for a mean of 99 months (range, 63-123 months) with chest x-rays and for a mean of 62 months (range, 3-101 months) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not available anymore, but use of these balloons for embolization of pulmonary arteriovenousmore » malformations has been shown to be a safe and precise method, with immediate occlusion of the feeding artery and with long-lasting occlusion, even though many balloons deflate with time, leaving a fibrotic scar replacing the pulmonary arteriovenous malformation. No case of recanalization has been discovered, and these results seem to justify a reduced number of controls of these balloon-embolized malformations.« less
Euser, Anja S; van Meel, Catharina S; Snelleman, Michelle; Franken, Ingmar H A
2011-09-01
Although risky decision-making is one of the hallmarks of alcohol use disorders, relatively little is known about the acute psychopharmacological effects of alcohol on decision-making processes. The present study investigated the acute effects of alcohol on neural mechanisms underlying feedback processing and outcome evaluation during risky decision-making, using event-related brain potentials (ERPs). ERPs elicited by positive and negative feedback were recorded during performance of a modified version of the Balloon Analogue Risk Task in male participants receiving either a moderate dose of alcohol (0.65 g/kg alcohol; n = 32) or a non-alcoholic placebo beverage (n = 32). Overall, there was no significant difference in the mean number of pumps between the alcohol and the placebo condition. However, when analyzing over time, it was found that the alcohol group made more riskier choices at the beginning of the task than the placebo group. ERPs demonstrated that alcohol consumption did not affect early processing of negative feedback, indexed by the feedback-related negativity. By contrast, alcohol-intoxicated individuals showed significantly reduced P300 amplitudes in response to negative feedback as compared to sober controls, suggesting that more elaborate evaluation to losses was significantly diminished. These results suggest that alcohol consumption does not influence the ability to rapidly evaluate feedback valence, but rather the ability to assign sufficient attention to further process motivationally salient outcomes. Blunted P300 amplitudes may reflect poor integration of feedback across trials, particularly adverse ones. Consequently, alcohol may keep people from effectively predicting the probability of future gains and losses based on their reinforcement history.
Tenenbaum, Rachel B; Musser, Erica D; Raiker, Joseph S; Coles, Erika K; Gnagy, Elizabeth M; Pelham, William E
2018-07-01
Attention-deficit/hyperactivity disorder (ADHD) is associated with disruptionsin reward sensitivity and regulatory processes. However, it is unclear whether thesedisruptions are better explained by comorbid disruptive behavior disorder (DBD)symptomology. This study sought to examine this question using multiple levels ofanalysis (i.e., behavior, autonomic reactivity). One hundred seventeen children (aged 6 to 12 years; 72.6% male; 69 with ADHD) completed theBalloon-Analogue Risk Task (BART) to assess external reward sensitivity behaviorally.Sympathetic-based internal reward sensitivity and parasympathetic-based regulationwere indexed via cardiac pre-ejection period (PEP) and respiratory sinus arrhythmia(RSA), respectively. Children with ADHD exhibited reduced internal reward sensitivity (i.e.,lengthened PEP; F(1,112)=4.01, p=0.047) compared to healthy controls and werecharacterized by greater parasympathetic-based dysregulation (i.e., reduced RSAaugmentation F(1,112)=10.12, p=0.002). However, follow-up analyses indicated theADHD effect was better accounted for by comorbid DBD diagnoses; that is, childrenwith ADHD and comorbid ODD were characterized by reduced internal rewardsensitivity (i.e., lengthened PEP; t=2.47, p=0.046) and by parasympathetic-baseddysregulation (i.e., reduced RSA augmentation; t=3.51, p=0.002) in response to rewardwhen compared to typically developing youth. Furthermore, children with ADHD and comorbid CD exhibited greater behaviorally-based external reward sensitivity (i.e.,more total pops; F(3,110)= 5.96, p=0.001) compared to children with ADHD only (t=3.87, p=0.001) and children with ADHD and ODD (t=3.56, p=0.003). Results suggest that disruptions in sensitivity to reward may be betteraccounted for, in part, by comorbid DBD.Key Words: attention-deficit/hyperactivity disorder, autonomic nervous system,disruptive behavior disorders, reward sensitivityPowered.
Ahn, Woo-Young; Vassileva, Jasmin
2016-04-01
Recent animal and human studies reveal distinct cognitive and neurobiological differences between opiate and stimulant addictions; however, our understanding of the common and specific effects of these two classes of drugs remains limited due to the high rates of polysubstance-dependence among drug users. The goal of the current study was to identify multivariate substance-specific markers classifying heroin dependence (HD) and amphetamine dependence (AD), by using machine-learning approaches. Participants included 39 amphetamine mono-dependent, 44 heroin mono-dependent, 58 polysubstance dependent, and 81 non-substance dependent individuals. The majority of substance dependent participants were in protracted abstinence. We used demographic, personality (trait impulsivity, trait psychopathy, aggression, sensation seeking), psychiatric (attention deficit hyperactivity disorder, conduct disorder, antisocial personality disorder, psychopathy, anxiety, depression), and neurocognitive impulsivity measures (Delay Discounting, Go/No-Go, Stop Signal, Immediate Memory, Balloon Analogue Risk, Cambridge Gambling, and Iowa Gambling tasks) as predictors in a machine-learning algorithm. The machine-learning approach revealed substance-specific multivariate profiles that classified HD and AD in new samples with high degree of accuracy. Out of 54 predictors, psychopathy was the only classifier common to both types of addiction. Important dissociations emerged between factors classifying HD and AD, which often showed opposite patterns among individuals with HD and AD. These results suggest that different mechanisms may underlie HD and AD, challenging the unitary account of drug addiction. This line of work may shed light on the development of standardized and cost-efficient clinical diagnostic tests and facilitate the development of individualized prevention and intervention programs for HD and AD. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Reference level winds from balloon platforms
NASA Technical Reports Server (NTRS)
Lally, Vincent E.
1985-01-01
The superpressure balloon was developed to provide a method of obtaining global winds at all altitudes from 5 to 30 km. If a balloon could be made to fly for several weeks at a constant altitude, and if it could be tracked accurately on its global circuits, the balloon would provide a tag for the air parcel in which it was embedded. The Lagrangian data on the atmospheric circulation would provide a superior data input to the numerical model. The Global Atmospheric Research Program (GARP) was initiated in large part based on the promise of this technique coupled with free-floating ocean buoys and satellite radiometers. The initial name proposed by Charney for GARP was SABABURA 'SAtellite BAlloon BUoy RAdiometric system' (Charney, 1966). However, although the superpressure balloon exceeded its designers' expectations for flight duration in the stratosphere (longest flight duration of 744 days), flight duration below 10 km was limited by icing in super-cooled clouds to a few days. The balloon was relegated to a secondary role during the GARP Special Observing Periods. The several major superpressure balloon programs for global wind measurement are described as well as those new developments which make the balloon once again an attractive vehicle for measurement of global winds as a reference and bench-mark system for future satellite systems.
Development of a Compact Captive Balloon and Its Level Supporting
NASA Astrophysics Data System (ADS)
Nakao, Tatsuya; Fujiwara, Kazuhito; Furukawa, Motoyasu; Hiroe, Tetsuyuki
Many kinds of observation techniques have been developed to obtain the properties of atmospheric conditions. The advanced observation techniques of the flow in relatively large scale are remote sensing by satellite facilities, long range observations by radar or Doppler Sodar, etc., while data from conventional climometers set at fixed places are merely limited information about local scale flow. Captive balloons are also available and feasible for the observation of local flows if their standing mechanics are robust against the strong wind and the motion of balloon are stable for all wind direction and the change of wind direction. In this paper, a compact captive balloon (about 2m diam.) for flow measurement is proposed and the preservation of balloon height level and the stabilization of its motion are challenged by using a kite. The relation between force balances acted on the balloon and the balloon height or position was estimated and confirmed in experiments. Although the lift force of single kite worked successfully, it is found that the performance of plural kites is less in the traction of balloon since the interaction of their tensions. The compact balloon supported by the kite enabled the over 300m floating by virtue of the small size causing only low air resistance.
Graham, D Y; Smith, J L
1985-06-01
Balloon esophageal dilatation offers many theoretical advantages (safety, speed, and patient comfort) over dilatation with mercury-filled bougies or with the Eder-Puestow system. The authors used balloon dilators in 22 patients with dysphagia secondary to benign or malignant strictures. Dilatation was performed with fluoroscopic guidance, blindly, or by a combination of these techniques. For "blind" stricture dilatation, an Eder-Puestow spring-tipped guide wire is placed into the stomach using a fiberoptic endoscope. The distance from the incisor teeth to the stricture is measured, and the balloon shaft is marked to indicate when the middle of the balloon is within the stricture. Dilatation is then performed using the antegrade or, the preferred, retrograde technique. Finally, the dilated stricture is calibrated by pulling an inflated balloon through the previously strictured area without difficulty. An attempt was made to achieve an esophageal diameter of 15 mm at the initial dilatation episode, and patient discomfort was used as a guide as to the final diameter. The balloon dilatation technique was highly successful, and a stricture diameter of 15 mm (45-47 French) was achieved at the initial dilatation in most instances. Malignant strictures were easily dilated. Balloon dilatation is convenient, effective, quick, and potentially safer than the previous Eder-Puestow or mercury-filled bougie techniques.
Power supplies for long duration balloon flights
NASA Astrophysics Data System (ADS)
Lichfield, Ernest W.
Long duration balloon flights require more electrical power than can be carried in primary batteries. This paper provides design information for selecting rechargeable batteries and charging systems. Solar panels for recharging batteries are discussed, with particular emphasis on cells mounting suitable for balloon flights and panel orientation for maximum power collection. Since efficient utilization of power is so important, modern DC to DC power conversion techniques are presented. On short flights of 1 day or less, system designers have not been greatly concerned with battery weight. But, with the advent of long duration balloon flights using superpressure balloons, anchor balloon systems, and RACOON balloon techniques, power supplies and their weight become of prime importance. The criteria for evaluating power systems for long duration balloon flights is performance per unit weight. Instrumented balloon systems have flown 44 days. For these very long duration flights, batteries recharged from solar cells are the only solution. For intermediate flight duration, say less than 10 days, the system designer should seriously consider using primary cells. The National Center for Atmospheric Research is sponsored by the National Science Foundation. Any opinions, findings and conclusions or recommendations expressed in this publication are those of the authors and do not necessarily reflect the views of the National Science Foundation.
Durvasula, Venkata S P B; Shalin, Sara C; Tulunay-Ugur, Ozlem E; Suen, James Y; Richter, Gresham T
2018-06-01
Cricoid fracture is a serious concern for balloon dilatation in airway stenosis. Furthermore, there are no studies examining tracheal rupture in balloon dilatation of stenotic segments. The aim of this study was to evaluate the effect of supramaximal pressures of balloons on the cricoid and tracheal rings. Prospective cadaveric study. Seven cadaveric laryngotracheal complexes of normal adults with intact cricothyroid membranes were acquired. Noncompliant vascular angioplasty balloons (BARD-VIDA) were used for dilatation. The subglottis and trachea were subjected to supramaximal dilatation pressures graduated to nominal burst pressure (NBP) and, if necessary, rated burst pressure (RBP). Larger-diameter balloons, starting from 18 mm size to 24 mm, were used. Dilatations were maintained for 3 minutes. The cricoid ring was disrupted by larger-diameter balloons (22 mm and 24 mm) even at lower pressures (less than NBP) in six cases. Tracheal cartilages were very distensible, and external examination after supramaximal dilatation (24 mm close to RBP) revealed no obvious cartilage fractures or trachealis tears. Histopathological examination revealed sloughing of mucosa in the areas corresponding to balloon placement, but no microfractures or disruption of the perichondrium of tracheal ring cartilages. These results indicate that the cricoid is vulnerable to injury from larger balloons even at lower dilatation pressures. The tracheal cartilages and the membranous wall of the trachea remained resilient to supramaximal dilatation and larger balloons. NA. Laryngoscope, 128:1304-1309, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Usefulness of cutting balloon angioplasty for the treatment of congenital heart defects.
Kusa, Jacek; Mazurak, Magdalena; Skierska, Agnieszka; Szydlowski, Leslaw; Czesniewicz, Pawel; Manka, Lukasz
2018-01-01
Patients with complex congenital heart defects may have different hemodynamic prob-lems which require a variety of interventional procedures including angioplasty which involves using high-pressure balloons. After failure of conventional balloon angioplasty, cutting balloon angioplasty is the next treatment option available. The purpose of this study was to evaluate the safety and efficacy of cutting balloon angioplasty in children with different types of congenital heart defects. Cutting balloon angioplasty was performed in 28 children with different congenital heart defects. The indication for cutting balloon angioplasty was: pulmonary artery stenosis in 17 patients, creating or dilatation of interatrial communication in 10 patients, and stenosis of left subclavian artery in 1 patient. In the pulmonary arteries group there was a significant decrease in systolic blood pressure (SBP) in the proximal part of the artery from the average 74.33 ± 20.4 mm Hg to 55 ± 16.7 mm Hg (p < 0.001). Distal to the stenosis there was an increase in SBP from 19.8 ± 3.82 mm Hg to 30.3 ± ± 13.3 mm Hg (p = 0.04). This result remained constant in the follow-up. In atrial septal defect/fenestra-tion group, cutting balloon angioplasty was performed after an unsuccessful classic Rashkind procedure. After cutting balloon angioplasty there was a significant widening of the interatrial communication. Cutting balloon angioplasty is a feasible and effective treatment option in different con-genital heart defects.
Gelsomino, Sandro; Lozekoot, Pieter W J; Lorusso, Roberto; de Jong, Monique M J; Parise, Orlando; Matteucci, Francesco; Lucà, Fabiana; La Meir, Mark; Gensini, Gian Franco; Maessen, Jos G
2016-05-01
We compare a short and a standard-size balloon with same filling volumes to verify the differences in terms of visceral flow, coronary circulation and haemodynamic performance during aortic counterpulsation in an animal model of myocardial ischaemia-reperfusion injury. Eighteen healthy pigs underwent 120-min ligation of the left anterior descending coronary artery followed by 6 h of reperfusion, and they were randomly assigned to have intra-aortic balloon counterpulsation (IABP) with a 40-ml short-balloon (n = 6) or a 40-ml standard-length balloon (n = 6), or to undergo no IABP implantation (controls, n = 6). Haemodynamics and visceral and coronary flows were measured at baseline (t0), at 2 h of ischaemia (t1) and every hour thereafter until 6 h of reperfusion (from tR1 to tR6), respectively. Mesenteric flows increased significantly at tR1 only in the short-balloon group (P < 0.001) and it was constantly higher than in the standard-balloon group regardless of mean arterial pressure, systemic vascular resistance and cardiac output (CO; all, P < 0.001). Renal blood flows were significantly increased during IABP treatment with values constantly and significantly higher in short balloons at any following experimental step (all, P < 0.05). IABP improved CO and coronary blood flow, and reduced afterload, myocardial resistances and myocardial oxygen consumption without differences between the short and the standard-length balloon (all, P > 0.05). The short balloon prevents visceral ischaemia and, compared with the standard-size balloon, it does not lose IABP beneficial cardiac and coronary-related effects. Further studies are warranted to confirm our findings. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Tokuda, Michifumi; Matsuo, Seiichiro; Kato, Mika; Sato, Hidenori; Oseto, Hirotsuna; Okajima, Eri; Ikewaki, Hidetsugu; Isogai, Ryota; Tokutake, Kenichi; Yokoyama, Kenichi; Narui, Ryohsuke; Tanigawa, Shin-Ichi; Yamashita, Seigo; Inada, Keiichi; Yoshimura, Michihiro; Yamane, Teiichi
2017-09-01
Asymptomatic cerebral embolism (ACE) is sometimes detected after cryoballoon ablation of atrial fibrillation. The removal of air bubbles from the cryoballoon before utilization may reduce the rate of ACE. This study aims to compare the incidence of ACE between a conventional and a novel balloon massaging method during cryoballoon ablation. Of 175 consecutive patients undergoing initial cryoballoon ablation of paroxysmal atrial fibrillation, 60 (34.3%) patients underwent novel balloon massaging with extracorporeal balloon inflation in saline water (group N) before the cryoballoon was inserted into the body. The remaining 115 (65.7%) patients underwent conventional balloon massaging in saline water while the balloon remained folded (group C). Of those, 86 propensity score-matched patients were included. The baseline characteristics were similar between the 2 groups. In group N, even after balloon massaging in saline water was carefully performed, multiple air bubbles remained on the balloon surface when the cryoballoon was inflated in all cases. Postprocedural cerebral magnetic resonance imaging detected ACE in 14.0% of all patients. The incidence of ACE was significantly lower in group N than in group C (4.7% vs 23.3%; P = .01). According to multivariable analysis, the novel method was the sole factor associated with the presence of ACE (odds ratio 0.161; 95% confidence interval 0.033-0.736; P = .02). Preliminary removal of air bubbles in heparinized saline water with extracorporeal balloon inflation reduced the incidence of ACE. Since conventional balloon massaging failed to remove air bubbles completely, this novel balloon massaging method should be recommended before cryoballoon utilization. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
de Castro, Maria Luisa; Morales, Maria Jose; Martínez-Olmos, Miguel A; Pineda, Juan R; Cid, Lucia; Estévez, Pamela; del-Campo, Victor; Rodríguez-Prada, J Ignacio
2013-10-01
intragastric balloons provide early satiety and thereby induce short-term weight loss. The aim of this study was to evaluate safety and short and medium-term effectiveness of gastric balloons associated to hypocaloric diet in obesity. from May 2004 to June 2011 91 obese patients, body mass index (BMI) 45.2 +/- 7.2 kg/m2 were prospectively followed after endoscopic implantation of a gastric balloon associated to restricted diet. Successful therapy was defined as percent loss of total weight (%LTW) > or = 5 % at six months after balloon placement and 6 and 12 months after their withdrawal. All analyses followed intention-to treat principles considering significant p-values < 0.05. we placed 73 fluid-filled balloons (80.2 %) and 18 air-filled ones (19.8 %). Compared to baseline values, at 6-month 73.7 % subjects succeeded, showing significant reductions in weight (13.3 +/- 8.8 kg), BMI (5 +/- 3.4 kg/m2) (p < 0.0001), with % LTW 11 +/- 7 %. Six and twelve months after retrieval 45.1 % and 28.6 % patients reached % LTW > or = 5 %. Short-term and medium-term effectiveness was negatively associated to obesity in first-grade relatives (p = 0.003 and p = 0.04). Higher weight loss 6 months after balloon placement independently predicted medium-term effectiveness (p = 0.0001). Mortality was absent but there were two spontaneous deflations of air-filled balloons and severe withdrawal difficulties in 8 patients, leading to surgery in one case. Retrieval complications associated to air-filled balloons (p = 0.0005). in obesity, effectiveness of gastric balloons associated to hypocaloric diet decreases over time.Complications occurred mainly in the retrieval endoscopic procedure and related to air-filled balloons.
Bo, Liyan; Li, Congcong; Chen, Min; Mu, Deguang; Jin, Faguang
Electrocautery needle knives can largely reduce scar and granulation tissue hyperplasia and play an important role in treating patients with benign stricture. The aim of this retrospective study was to evaluate the efficacy and safety of electrocautery needle knife combined with balloon dilatation versus balloon dilatation alone in the treatment of tracheal stenosis caused by tracheal intubation or tracheotomy. We retrospectively analysed the clinical data of 43 patients with tracheal stenosis caused by tracheotomy or tracheal intubation in our department from January 2013 to January 2016. Among these 43 patients, 23 had simple web-like stenosis and 20 had complex steno sis. All patients were treated under general anaesthesia, and the treatment methods were (1) balloon dilatation alone, (2) needle knife excision of fibrotic tissue combined with balloon dilatation, and (3) needle knife radial incision of fibrotic tissue combined with balloon dilatation. After treatment the symptoms, such as shortness of breath, were markedly improved immediately in all cases. The stenosis degree of patients who were treated with the elec-trocautery needle knife combined with balloon dilatation had better improvement compared with that of those treated with balloon dilatation treatment alone after 3 months (0.45 ± 0.04 vs. 0.67 ± 0.05, p < 0.01), and the proportion of restenosis occurrence that required further treatment was decreased at 6 months (46.9 vs. 81.8%), especially for the web-like stenosis patients, as most of their stenoses dilated with no obvious restenosis and achieved clinical cure. Electrocautery needle knife combined with balloon dilatation is an effective and safe treatment for tracheal fibrotic stenosis compared with balloon dilatation alone. © 2017 S. Karger AG, Basel.
Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients.
Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young
2015-01-01
The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05). The drainage amount over 1 hour was 500 mL (20-1200 mL) in the balloon failure group and 60 mL (5-500 mL) in the balloon success group (p<0.01). Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.
Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients
Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young
2015-01-01
Purpose The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. Methods We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Results Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05). The drainage amount over 1 hour was 500 mL (20–1200 mL) in the balloon failure group and 60 mL (5–500 mL) in the balloon success group (p<0.01). Conclusion Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance. PMID:26263014
Lamichhane, Sujan; Anderson, Jordan; Remund, Tyler; Kelly, Patrick
2015-01-01
Abstract Drug‐coated balloons (DCBs) have now emerged as a promising approach to treat peripheral artery disease. However, a significant amount of drug from the balloon surface is lost during balloon tracking and results in delivering only a subtherapeutic dose of drug at the diseased site. Hence, in this study, the use of dextran sulfate (DS) polymer was investigated as a platform to control the drug release from balloons. An antiproliferative drug, paclitaxel (PAT), was incorporated into DS films (PAT‐DS). The characterizations using SEM, FT‐IR, and DSC showed that the films prepared were smooth and homogenous with PAT molecularly dispersed in the bulk of DS matrix in amorphous form. An investigation on the interaction of smooth muscle cells (SMCs) with control‐DS and PAT‐DS films showed that both films inhibited SMC growth, with a superior inhibitory effect observed for PAT‐DS films. PAT‐DS coatings were then produced on balloon catheters. The integrity of coatings was well‐maintained when the balloons were either deflated or inflated. In this study, up to 2.2 µg/mm2 of PAT was loaded on the balloons using the DS platform. Drug elution studies showed that only 10 to 20% of the total PAT loaded was released from the PAT‐DS coated balloons during the typical time period of balloon tracking (1 min) and then ∼80% of the total PAT loaded was released during the typical time period of balloon inflation and treatment (from 1 min to 4 min). Thus, this study demonstrated the use of DS as a platform to control drug delivery from balloons. © 2015 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1416–1430, 2016. PMID:26227252
Lin, Yuan-xiang; Lin, Kun; Kang, De-zhi; Liu, Xin-xiu; Wang, Xing-fu; Zheng, Shu-fa; Yu, Liang-hong; Lin, Zhang-ya
2015-05-01
Dysmorphic neurons and balloon cells constitute the neuropathological hallmarks of type II focal cortical dysplasias (FCDs) with refractory epilepsy. The genesis of these cells may be critical to the histological findings in type II FCD. Recent work has shown enhanced activation of the mTOR cascade in both balloon cells and dysmorphic neurons, suggesting a common pathogenesis for these two neuropathological hallmarks. A direct comparative analysis of balloon cells and dysmorphic neurons might identify a molecular link between balloon cells and dysmorphic neurons. Here, we addressed whether PDK1-AKT-mTOR activation differentiates balloon cells from dysmorphic neurons. We used immunohistochemistry with antibodies against phosphorylated (p)-PDK1 (Ser241), p-AKT (Thr308), p-AKT (Ser473), p-mTOR (Ser2448), p-P70S6K (Thr229), and p-p70S6 kinase (Thr389) in balloon cells compared with dysmorphic neurons. Strong or moderate staining for components of the PDK1-AKT-mTOR signaling pathway was observed in both balloon cells and dysmorphic neurons. However, only a few pyramidal neurons displayed weak staining in control group (perilesional neocortex and histologically normal neocortex). Additionally, p-PDK1 (Ser241) and p-AKT (Thr308) staining in balloon cells were stronger than in dysmorphic neurons, whereas p-P70S6K (Thr229) and p-p70S6 kinase (Thr389) staining in balloon cells was weaker than in dysmorphic neurons. In balloon cells, p-AKT (Ser473) and p-mTOR (Ser2448) staining was comparable with the staining in dysmorphic neurons. Our data support the previously suggested pathogenic relationship between balloon cells and dysmorphic neurons concerning activation of the PDK1-AKT-mTOR, which may play important roles in the pathogenesis of type II FCD. Differential expression of some components of the PDK1-AKT-mTOR pathway between balloon cells and dysmorphic neurons may result from cell-specific gene expression. Copyright © 2015 Elsevier B.V. All rights reserved.
High altitude flights in equatorial regions
NASA Astrophysics Data System (ADS)
Redkar, R. T.
A thorough analysis of balloon flights made from Hyderabad, India (Latitude 17°28'N, Longitude 78°35'E), and other equatorial sites has been made. It has been shown that limited success is expected for flights made from equatorial latitudes with balloons made out of natural colour polyethylene film, since the best known balloon film in the world today viz. Winzen Stratofilm is tested for low temperature brittleness only at -80°C., whereas the tropopause temperatures over equatorial latitudes vary between -80°C and -90°C. The success becomes even more critical when flights are made with heavy payloads and larger balloons particularly at night when in the absence of solar radiation the balloon film becomes more susceptible to low temperature brittle failure. It is recommended that in case of capped balloons longer caps should be used to fully cover the inflated protion of the balloon at the higher level equatorial tropopause. It is also advised that the conditions such as wind shears in the tropopause should be critically studied before launching and a day with the tropopause temperature nearer to -80°C should be chosen. Special care also should be taken while handling the balloon on ground and during launching phase. Properties of Winzen Stratofilm have been critically studied and fresh mandates have been recommended on the basis of limiting values of film stresses which caused balloon failures in the equatorial tropopause. It is also emphasized that the data on such flights is still meagre especially for flights with heavy payloads and larger balloons. It has been also shown that it is safest to use balloons made out of grey coloured film which retains its flexibility with the absorption of solar radiation, the success obtained with such balloons so far being 100%. The drawback, however, is that these balloons cannot be used for night flights. Stratospheric wind regimes over Hyderabad are also discussed with a view to determine the period over which long duration flights can be made. The data available, however, is meagre and it is recommended that more frequent special wind ascents be made to collect adequate statistical data from which reliable conclusions could be drawn through critical analysis.
The NASA super pressure balloon - A path to flight
NASA Astrophysics Data System (ADS)
Cathey, H. M.
2009-07-01
The National Aeronautics and Space Administration's Balloon Program Office has invested significant time and effort in extensive ground testing of model super pressure balloons. The testing path has been developed as an outgrowth of the results of the super pressure balloon test flight in 2006. Summary results of the June 2006 super pressure test flight from Kiruna, Sweden are presented including the balloon performance and "lessons learned". This balloons flight performance exceeded expectations, but did not fully deploy. The flight was safely terminated by command. The results of this test flight refocused the project's efforts toward additional ground testing and analysis; a path to flight. A series of small 4 m diameter models were made and tested to further explore the deployment and structural capabilities of the balloons and materials. A series of ˜27 m model balloons were successfully tested indoors. These balloons successfully replicated the cleft seen in the Sweden flight, explored the deployment trade space to help characterize better design approaches, and demonstrated an acceptable fix to the deployment issue. Photogrammetry was employed during these ˜27 m model tests to help characterize both the balloon and gore shape evolution under pressurization. A ˜8.5 m ground model was used to explore the design and materials performance. Results of these tests will be presented. A general overview of some of the other project advancements made related to demonstrating the strain arresting nature of the proposed design, materials and analysis work will also be presented. All of this work has prepared a clear path toward a renewed round of test flights. This paper will give an overview of the development approach pursued for this super pressure balloon development. A description of the balloon design, including the modifications made as a result of the lessons learned, is presented. A short deployment test flight of the National Aeronautics and Space Administration's super pressure balloon took place in June 2008. This flight was from Ft. Sumner, New Mexico. Preliminary results of this flight are presented. Future plans for both ground testing and additional test flights are also presented. Goals of the future test flights, which are staged in increments of increasing suspended load and altitude, are presented. This includes the projected balloon volumes, payload capabilities, test flight locations, and proposed flight schedule.
An analysis of the deployment of a pumpkin balloon on mars
NASA Astrophysics Data System (ADS)
Rand, J.; Phillips, M.
The design of large superpressure balloons has received significant attention in recent years due to the successful demonstration of various enabling technologies and materials. Of particular note is the "pumpkin" shaped balloon concept, which allows the stress in the envelope to be limited by the surface geometry. Unlike a sphere, which produces stress resultants determined by the volume of the system, the pumpkin utilizes a system of meridional tendons to react the loading in one direction, and form a number of lobes, which limit the stress in the circumferential direction. The application of this technology to very large systems is currently being demonstrated by NASA's Ultra Long Duration Balloon (ULDB) Program. However, this type of balloon has certain features that may be exploited to produce a system far more robust than a comparable sphere during deployment, inflation, and operation for long periods of time. When this concept is applied to a system designed to carry two kilograms in the atmosphere of Mars, the resulting balloon is small enough to alter the construction techniques and produce an envelope which is free of tucks and folds which may cause uncontrolled stress concentrations. A technique has been demonstrated where high strength tendons may be pretensioned prior to installation along the centerline of each gore. Since this position is the shortest distance between the apex and nadir of the balloon, the tendons will automatically resist the forces caused by deployment and inflation and thereby protect the thin film gas barrier from damage. A suitable balloon has been designed for this type of mission using five-micron Mylar Type C film for the gas barrier and P O braided cables for the meridionalB load carrying members. The deployment of this balloon is assumed to occur while falling on a decelerator suitably designed for the Mars atmosphere. The inflation is accomplished by a ten-kilogram system suspended at the nadir of the balloon. As the system falls toward the surface of the planet, helium gas is transferred to the balloon, forming a partially inflated system very similar to an ascending zero pressure balloon. This analysis incorporates the flow of the planetary gas around the inflating balloon, altering the pressure distribution and shape. As a result, stresses are seen to increase beyond the design margin of safety, requiring the balloon to be redesigned. In addition, several scale models of this balloon were dynamically deployed in the laboratory to demonstrate that the deployment forces are indeed carried by the tendons
Kayssi, Ahmed; Al-Atassi, Talal; Oreopoulos, George; Roche-Nagle, Graham; Tan, Kong Teng; Rajan, Dheeraj K
2016-08-04
Atherosclerotic peripheral arterial disease (PAD) can lead to disabling ischemia and limb loss. Treatment modalities have included risk factor optimization through life-style modifications and medications, or operative approaches using both open and minimally invasive techniques, such as balloon angioplasty. Drug-eluting balloon (DEB) angioplasty has emerged as a promising alternative to uncoated balloon angioplasty for the treatment of this difficult disease process. By ballooning and coating the inside of atherosclerotic vessels with cytotoxic agents, such as paclitaxel, cellular mechanisms responsible for atherosclerosis and neointimal hyperplasia are inhibited and its devastating complications are prevented or postponed. DEBs are considerably more expensive than uncoated balloons, and their efficacy in improving patient outcomes is unclear. To assess the efficacy of drug-eluting balloons (DEBs) compared with uncoated, nonstenting balloon angioplasty in people with symptomatic lower-limb peripheral arterial disease (PAD). The Cochrane Vascular Trials Search Co-ordinator (TSC) searched the Specialised Register (last searched December 2015) and Cochrane Register of Studies (CRS) (2015, Issue 11). The TSC searched trial databases for details of ongoing and unpublished studies. We included all randomized controlled trials that compared DEBs with uncoated, nonstenting balloon angioplasty for intermittent claudication (IC) or critical limb ischemia (CLI). Two review authors (AK, TA) independently selected the appropriate trials and performed data extraction, assessment of trial quality, and data analysis. The senior review author (DKR) adjudicated any disagreements. Eleven trials that randomized 1838 participants met the study inclusion criteria. Seven of the trials included femoropopliteal arterial lesions, three included tibial arterial lesions, and one included both. The trials were carried out in Europe and in the USA and all used the taxane drug paclitaxel in the DEB arm. Nine of the 11 trials were industry-sponsored. Four companies manufactured the DEB devices (Bard, Bavaria Medizin, Biotronik, and Medtronic). The trials examined both anatomic and clinical endpoints. There was heterogeneity in the frequency of stent deployment and the type and duration of antiplatelet therapy between trials. Using GRADE assessment criteria, the quality of the evidence presented was moderate for the outcomes of target lesion revascularization and change in Rutherford category, and high for amputation, primary vessel patency, binary restenosis, death, and change in ankle-brachial index (ABI). Most participants were followed up for 12 months, but one trial reported outcomes at five years.There were better outcomes for DEBs for up to two years in primary vessel patency (odds ratio (OR) 1.47, 95% confidence interval (CI) 0.22 to 9.57 at six months; OR 1.92, 95% CI 1.45 to 2.56 at 12 months; OR 3.51, 95% CI 2.26 to 5.46 at two years) and at six months and two years for late lumen loss (mean difference (MD) -0.64 mm, 95% CI -1.00 to -0.28 at six months; MD -0.80 mm, 95% CI -1.44 to -0.16 at two years). DEB were also superior to uncoated balloon angioplasty for up to five years in target lesion revascularization (OR 0.28, 95% CI 0.17 to 0.47 at six months; OR 0.40, 95% CI 0.31 to 0.51 at 12 months; OR 0.28, 95% CI 0.18 to 0.44 at two years; OR 0.21, 95% CI 0.09 to 0.51 at five years) and binary restenosis rate (OR 0.44, 95% CI 0.29 to 0.67 at six months; OR 0.38, 95% CI 0.15 to 0.98 at 12 months; OR 0.26, 95% CI 0.10 to 0.66 at two years; OR 0.12, 95% CI 0.05 to 0.30 at five years). There was no significant difference between DEB and uncoated angioplasty in amputation, death, change in ABI, change in Rutherford category and quality of life (QoL) scores, or functional walking ability, although none of the trials were powered to detect a significant difference in these clinical endpoints. We carried out two subgroup analyses to examine outcomes in femoropopliteal and tibial interventions as well as in people with CLI (4 or greater Rutherford class), and showed no advantage for DEBs in tibial vessels at six and 12 months compared with uncoated balloon angioplasty. There was also no advantage for DEBs in CLI compared with uncoated balloon angioplasty at 12 months. Based on a meta-analysis of 11 trials with 1838 participants, there is evidence of an advantage for DEBs compared with uncoated balloon angioplasty in several anatomic endpoints such as primary vessel patency (high-quality evidence), binary restenosis rate (moderate-quality evidence), and target lesion revascularization (low-quality evidence) for up to 12 months. Conversely, there is no evidence of an advantage for DEBs in clinical endpoints such as amputation, death, or change in ABI, or change in Rutherford category during 12 months' follow-up. Well-designed randomized trials with long-term follow-up are needed to compare DEBs with uncoated balloon angioplasties adequately for both anatomic and clinical study endpoints before the widespread use of this expensive technology can be justified.
Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside
Saxon, John T; Allen, Keith B; Cohen, David J
2018-01-01
Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient–prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient–prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions. PMID:29593832
Rodríguez-Arias, Carlos; Crespo, Eduardo; Pérez-Fernández, Santiago; Arenillas, Juan F; Martínez-Galdámez, Mario
2015-01-01
Cocaine is a widespread recreational drug that has the potential to induce neurological vascular diseases, including ischaemic and haemorrhagic stroke. Although arterial vasospasm has been suggested as a pathogenic factor in the development of neurovascular complications, it remains unclear whether cocaine users carry an increased risk to suffer iatrogenic vasospasm during endovascular procedures. We report the case of two patients with a history of cocaine abuse, who developed unusual severe vasospasms during different interventional procedures. The first case occurred in a middle-aged woman with an unruptured left internal carotid artery bifurcation aneurysm who was scheduled for treatment by remodelling assisted coiling. Just after the placement of the remodelling balloon, a severe occlusive vasospasm interrupted the procedure. The second case happened to a 46-year-old man with a non-aneurysmal subarachnoid haemorrhage and a symptomatic vasospasm in the right-sided anterior circulation who developed another occlusive vasospasm after the first attempt at transluminal balloon angioplasty. Further research is needed to establish a relation between cocaine use and increased risk of iatrogenic vasospasm in endovascular procedures, but we suggest practitioners be extremely cautious when treating this subgroup of patients. PMID:25934770
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-14
... flying hot air balloons transiting across the Lower Mississippi River. Entry into this zone is prohibited... mariners from the safety hazards associated with a fireworks display and low flying hot air balloons... mariners from the safety hazards associated with a fireworks display and low flying hot air balloons...
Lightweight Valve Closes Duct Quickly
NASA Technical Reports Server (NTRS)
Fournier, Walter L.; Burgy, N. Frank
1991-01-01
Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.
Retrieval of impacted broken balloon by balloon inflation in guiding catheter.
Mehta, Vimal; Pandit, Bhagya Narayan; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay; Tyagi, Sanjay
2014-07-01
Broken catheter fragment in a coronary artery during percutaneous coronary angioplasty is a rare complication. It can result in serious problems as a result of thrombus formation and embolization of broken fragment. We report an unusual complication of a broken balloon catheter during angioplasty, which was successfully retrieved by balloon inflation in guiding catheter technique.
JACEE long duration balloon flights. [Japanese-American Cooperative Emulsion Experiment
NASA Technical Reports Server (NTRS)
Burnett, T.; Iwai, J.; Dake, S.; Derrickson, J.; Fountain, W.; Fuki, M.; Gregory, J.; Hayashi, T.; Holynski, R.; Jones, W. V.
1989-01-01
JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1 to 100A TeV. Experiments with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed.
NASA Langley Research Center tethered balloon systems
NASA Technical Reports Server (NTRS)
Owens, Thomas L.; Storey, Richard W.; Youngbluth, Otto
1987-01-01
The NASA Langley Research Center tethered balloon system operations are covered in this report for the period of 1979 through 1983. Meteorological data, ozone concentrations, and other data were obtained from in situ measurements. The large tethered balloon had a lifting capability of 30 kilograms to 2500 meters. The report includes descriptions of the various components of the balloon systems such as the balloons, the sensors, the electronics, and the hardware. Several photographs of the system are included as well as a list of projects including the types of data gathered.
Kwan, E S; Heilman, C B; Shucart, W A; Klucznik, R P
1991-12-01
Two patients with distal basilar aneurysms were treated with intra-aneurysmal balloon occlusion. After apparently successful therapy, follow-up angiograms demonstrated aneurysm enlargement with balloon migration distally in the sac. Geometric mismatch between the base of the balloons and the aneurysm neck together with transmitted pulsation through the 2-hydroxyl-ethylmethacrylate (HEMA)-filled balloon directly contributed to aneurysm enlargement. In this report, the authors discuss the problems of progressive aneurysm enlargement due to a "water-hammer effect" and the possibility of hemorrhage following subtotal occlusion.
Early Cosmic Ray Research with Balloons
NASA Astrophysics Data System (ADS)
Walter, Michael
2013-06-01
The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.
ERIC Educational Resources Information Center
Walsh, Kate; DiLillo, David; Messman-Moore, Terri L.
2012-01-01
The present study examined whether and which facets of emotion dysregulation serve an intervening role in the association between prior victimization and risk perception in an analogue sexual assault vignette. Participants were 714 university women who completed self-report measures of sexual victimization, emotion dysregulation, and a…
Yamamoto, H; Hughes, R W; Schroeder, K W; Viggiano, T R; DiMagno, E P
1992-03-01
To determine whether the natural history of strictures is affected by the type of dilator used to treat newly diagnosed peptic strictures, we designed a prospective randomized trial to compare the results after Eder-Puestow or Medi-Tech balloon dilation. We entered 31 patients into the trial. We also prospectively followed up all 92 nonrandomized patients who underwent their first dilation for a benign stricture during the same period as the prospective randomized trial. The nonrandomized patients also underwent dilation with either the Eder-Puestow or the balloon technique at the discretion of the gastroenterologist performing the endoscopy. We found no statistically significant differences in the immediate or long-term results of the two methods among the randomized, nonrandomized, and overall combined groups. All but 1 of the 123 patients had immediate relief of dysphagia. Within each group of patients, the probability of remaining free of dysphagia 1 year after the initial dilation was approximately 20%, and the probability of not requiring a second dilation was approximately 65% with either technique. Major (esophageal rupture) and minor (bleeding or chest pain) complications occurred in 1% and 5% of the patients and 0.4% and 3% of the total dilation procedures, respectively. The esophageal rupture and four of six minor complications occurred after repeated dilations. Five of the six minor complications occurred with use of the Eder-Puestow dilators. We conclude that Eder-Puestow and balloon dilations of benign esophageal strictures are associated with similar outcomes, but repeated dilations and the Eder-Puestow technique may be associated with an increased risk of complications.
Spiro, Jon; Venugopal, Vinod; Raja, Yogesh; Ludman, Peter F; Townend, Jonathan N; Doshi, Sagar N
2015-05-01
Assessment of the feasibility and outcomes of the 2.5 L and 3.8 L Impella cardiac pump in patients with severe aortic stenosis (AS) and left ventricular impairment undergoing percutaneous revascularization (PCI) with or without balloon aortic valvuloplasty (BAV). We reviewed the clinical and procedural findings from a consecutive series of unselected patients with severe AS who underwent PCI during Impella support. In addition, we describe novel "balloon-assist" techniques that allowed implantation of Impella into the left ventricle (LV) when initial unassisted attempts failed. Five patients with severe AS were identified (four males, age 78.2 years, aortic valve area (AVA) 0.6 cm(2) , left ventricular ejection fraction (LVEF) 24 ± 5%, mean Society of Thoracic Surgeons (STS) mortality 11% (range 3-17%)). The Impella catheter traversed the aortic valve (AV) unassisted in only one patient, with four cases requiring balloon-assist techniques. All patients underwent planned revascularisation; mean procedure time 177 min (range 135-252 min), mean number of stents 3.4 (range 1-8), with three patients requiring rotational atherectomy. All procedures were well tolerated, with absence of arrhythmia, hypotension, pulmonary edema, stroke, or myocardial infarction. One patient died 48 hr post-PCI of multi-organ failure. The four remaining patients were well at 30 days. Implantation of the 2.5 and 3.8 L Impella appears feasible in patients with severe AS and left ventricle (LV) impairment. A balloon-assist technique may be used to facilitate device implantation when initial unassisted attempts fail. Improved hemodynamic stability may enhance the tolerability of lengthy and complex procedures. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Beauchamp, P. M.; Lunine, J.; Lebreton, J.; Coustenis, A.; Matson, D.; Reh, K.; Erd, C.
2008-12-01
In 2005, the Huygens Probe gave us a snapshot of a world tantalizingly like our own, yet frozen in its evolution on the threshold of life. The descent under parachute, like that of Huygens in 2005, is happening again, but this time in the Saturn-cast twilight of winter in Titan's northern reaches. With a pop, the parachute is released, and then a muffled splash signals the beginning of the first floating exploration of an extraterrestrial sea-this one not of water but of liquid hydrocarbons. Meanwhile, thousands of miles away, a hot air balloon, a "montgolfiere," cruises 6 miles above sunnier terrain, imaging vistas of dunes, river channels, mountains and valleys carved in water ice, and probing the subsurface for vast quantities of "missing" methane and ethane that might be hidden within a porous icy crust. Balloon and floater return their data to a Titan Orbiter equipped to strip away Titan's mysteries with imaging, radar profiling, and atmospheric sampling, much more powerful and more complete than Cassini was capable of. This spacecraft, preparing to enter a circular orbit around Saturn's cloud-shrouded giant moon, has just completed a series of flybys of Enceladus, a tiny but active world with plumes that blow water and organics from the interior into space. Specialized instruments on the orbiter were able to analyze these plumes directly during the flybys. Titan and Enceladus could hardly seem more different, and yet they are linked by their origin in the Saturn system, by a magnetosphere that sweeps up mass and delivers energy, and by the possibility that one or both worlds harbor life. It is the goal of the NASA/ESA Titan Saturn System Mission (TSSM) to explore and investigate these exotic and inviting worlds, to understand their natures and assess the possibilities of habitability in this system so distant from our home world. Orbiting, landing, and ballooning at Titan represent a new and exciting approach to planetary exploration. The TSSM mission architecture inherently provides the optimal balance between science, risk, and cost using three guiding principles: Achieve science well beyond the high bar set by Cassini Huygens. The TSSM orbiter, lander, and balloon have been configured with instruments and operational concept that go well beyond Cassini-Huygens capabilities, thus ensuring dramatic remote observation and in situ science discoveries. Build upon successful design and operational experience and lessons learned. ESA has successful experience in designing and landing probes on Titan (Huygens), as does NASA in implementing an orbiter at Saturn (Cassini). Long life design rules and extensive operational experience in the Saturn system have been applied to form the TSSM concept. Lessons learned from Galileo, Cassini, New Horizons, and MRO have been applied to reduce risk and lower cost. Development by ESA of the montgolfiere combines prior experience with Earth and planetary balloon systems to enable innovative science and unprecedented mobility for surface exploration. Strong international partnership. TSSM represents a collaborative effort between NASA and ESA that is structured to provide the best possible mission at a reasonable cost to NASA and to ESA. This NASA-ESA partnership leverages resources to maximize science return, distribute risk, and ensure technical readiness.
Management of Retained Intervention Guide-wire: A Literature Review
Al-Moghairi, Abdulrahman M; Al-Amri, Hussein S
2013-01-01
Percutaneous coronary angioplasty is increasingly employed in the treatment of patients with complex coronary artery disease. Different steerable guide wires used to open occluded vessel and facilitate balloon and stent deployment. However, the guide-wire itself is not without hazard: it may perforate or dissect the vessel, but fracture or entrapment is uncommon. Its management depends on the clinical situation of the patient, as well as the position and length of the remnant. In this review we discuss the angioplasty guide-wire fracture and entrapment risk factors, potential risks and management. PMID:23116055
How Should We Perform Rotational Atherectomy to an Angulated Calcified Lesion?
Sakakura, Kenichi; Taniguchi, Yousuke; Matsumoto, Mitsunari; Wada, Hiroshi; Momomura, Shin-Ichi; Fujita, Hideo
2016-05-25
Rotational atherectomy to an angulated calcified lesion is always challenging. The risk of catastrophic complications such as a burr becoming stuck or vessel perforation is greater when the calcified lesion is angulated. We describe the case of an 83-year-old female suffering from unstable angina. Diagnostic coronary angiography revealed an angulated calcified lesion in the proximal segment of the right coronary artery. We performed rotational atherectomy to the lesion, but intentionally did not advance the rotational atherectomy burr beyond the top of the angulation. We controlled the rotational atherectomy burr and stopped it just before the top of the angulation to avoid complications. Following rotational atherectomy, balloon dilatation with a non-compliant balloon was performed, and drug-eluting stents were successfully deployed. In this manuscript, we provide a review of the literature on this topic, and discuss how rotational atherectomy to an angulated calcified lesion should be performed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giannoukas, Athanasios D., E-mail: agiannoukas@hotmail.com; Berczi, Viktor; Anoop, Unnikrishnan
The aim of this article is to report our experience in the diagnosis of two cases of iliac artery endofibrosis or arteriopathy, a rare entity occurring in high-performance athletes, presenting with intermittent claudication (right-sided in both) after maximal exercise. External iliac artery endofibrosis or arteriopathy is a likely diagnosis in competitive athletes free of cardiovascular risk factors who present with leg claudication. Arteriography and a papaverine-assisted mean pressure gradient across the iliac arteries of more than 10 mmHg is a useful diagnostic approach. Moreover, balloon angioplasty of the iliac artery in that patient, in whom a pressure gradient was detected,more » resulted in symptomatic relief for 2 months followed by mild symptom recurrence. Thus, although balloon angioplasty is feasible and safe, it might not be adequate to treat this entity and, thus, its value remains undefined.« less
Despott, Edward J; Murino, Alberto; Bourikas, Leonidas; Nakamura, Masanao; Ramachandra, Vino; Fraser, Chris
2015-05-01
Spiral enteroscopy is a recently introduced technology alternative to balloon-assisted enteroscopy for examination of the small bowel. To compare small bowel insertion depths and procedure duration by spiral enteroscopy and double-balloon enteroscopy performed in the same cohort of patients, in immediate succession, using the same method of insertion depth estimation. A prospective, back-to-back comparative study was performed in 15 patients. Spiral enteroscopy procedures were performed first and a tattoo was placed to mark the most distal point. Double-balloon enteroscopy passed the tattoo placed at spiral enteroscopy in 14/15 cases (93%). Median insertion depths for double-balloon enteroscopy and spiral enteroscopy were 265cm and 175cm, respectively (P=0.004). Median time to achieve maximal depth of insertion was significantly shorter for spiral enteroscopy compared with double-balloon enteroscopy (24min vs. 45min, respectively; P=0.0005). However, in 14 patients no differences were found in median time to reach the same insertion depth (P=0.28). Double-balloon enteroscopy achieved significantly greater small bowel insertion depth than spiral enteroscopy. Although overall double-balloon enteroscopy procedure duration was longer, the time taken to reach the same small bowel insertion depth by both spiral enteroscopy and double-balloon enteroscopy was similar. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Launching Garbage-Bag Balloons.
ERIC Educational Resources Information Center
Kim, Hy
1997-01-01
Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)
Dutch Viking TROS Aktua Special
NASA Technical Reports Server (NTRS)
1986-01-01
Footage shows the night vertical takeoff of the Viking Hollan hot air balloon. The crew is shown participating in survival technique training, boarding the plane to depart to Canada, and preparing for the vertical takeoff in the hot air balloon across the Atlantic Ocean. Scenes also include the making of the capsule for the balloon, some flight activities, and the landing of the balloon.
Heat Transfer Model for Hot Air Balloons
NASA Astrophysics Data System (ADS)
Llado-Gambin, Adriana
A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the modeling based on typical thermal input from a balloon propane burner. The burner duty cycle to keep a constant altitude can vary from 10% to 28% depending on the atmospheric conditions, and the ambient temperature is the parameter that most affects the total thermal input needed. The simulation and analysis also predict that the gas temperature inside the balloon decreases at a rate of -0.25 K/s when there is no burner activity, and it increases at a rate of +1 K/s when the balloon pilot operates the burner. The results were compared to actual flight data and they show very good agreement indicating that the major physical processes responsible for balloon performance aloft are accurately captured in the simulation.
Mechanical properties of ANTRIX balloon film and fabrication of single cap large volume balloons
NASA Astrophysics Data System (ADS)
Suneel Kumar, B.; Sreenivasan, S.; Subba Rao, J. V.; Manchanda, R. K.
2008-11-01
The zero pressure plastic balloons used for high altitude studies are generally made from polyethylene material. Tensile properties of the thin film polymer are the key parameters for material selection due to extremely low temperature of -90 °C encountered by the balloons in the tropopause region during the ascent at equatorial latitudes. The physical and structural properties of the material determine the uniformity of the stress distribution over the entire shell. Load stresses from the suspended load propagate via load tapes heat sealed along with the gore seals as per the balloon design. A balance between this heat seal strength and the film strength is a desirable property of the basic resin in terms of the bubble strength, gauge uniformity, and long-term storage properties. In addition, the design of the top shell of the balloon and its stress distribution play an important role since only a fraction of the balloon is deployed during the filling operation and the ascent. In this paper we describe the mechanical properties of the 'ANTRIX' film developed by us and the optimized design of single cap balloons, which have been successfully used in our experiments over the past 5 years.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeoh, Eric, E-mail: eric.yeoh@health.sa.gov.au; School of Medicine, University of Adelaide, Adelaide; Tam, William
Purpose: To evaluate and compare the effect of argon plasma coagulation (APC) and topical formalin for intractable rectal bleeding and anorectal dysfunction associated with chronic radiation proctitis. Methods and Materials: Thirty men (median age, 72 years; range, 49-87 years) with intractable rectal bleeding (defined as ≥1× per week and/or requiring blood transfusions) after radiation therapy for prostate carcinoma were randomized to treatment with APC (n=17) or topical formalin (n=13). Each patient underwent evaluations of (1) anorectal symptoms (validated questionnaires, including modified Late Effects in Normal Tissues–Subjective, Objective, Management, and Analytic and visual analogue scales for rectal bleeding); (2) anorectal motormore » and sensory function (manometry and graded rectal balloon distension); and (3) anal sphincteric morphology (endoanal ultrasound) before and after the treatment endpoint (defined as reduction in rectal bleeding to 1× per month or better, reduction in visual analogue scales to ≤25 mm, and no longer needing blood transfusions). Results: The treatment endpoint was achieved in 94% of the APC group and 100% of the topical formalin group after a median (range) of 2 (1-5) sessions of either treatment. After a follow-up duration of 111 (29-170) months, only 1 patient in each group needed further treatment. Reductions in rectal compliance and volumes of sensory perception occurred after APC, but no effect on anorectal symptoms other than rectal bleeding was observed. There were no differences between APC and topical formalin for anorectal symptoms and function, nor for anal sphincteric morphology. Conclusions: Argon plasma coagulation and topical formalin had comparable efficacy in the durable control of rectal bleeding associated with chronic radiation proctitis but had no beneficial effect on anorectal dysfunction.« less
Hanusch, Alex Lucas; de Oliveira, Guilherme Roberto; de Sabóia-Morais, Simone Maria Teixeira; Machado, Rafael Cosme; dos Anjos, Murilo Machado; Chen Chen, Lee
2015-01-01
Neolignans are secondary metabolites found in various groups of Angiosperms. They belong to a class of natural compounds with great diversity of chemical structures and pharmacological activities. These compounds are formed by linking two phenylpropanoid units. Several compounds that have ability to prevent genetic damage have been isolated from plants, and can be used to prevent or delay the development of tumor cells. Genetic toxicology evaluation is widely used in risk assessment of new drugs in preclinical screening tests. In this study, we evaluated the genotoxicity and cytotoxicity of the neolignan analogue 2-(4-nitrophenoxy)-1-phenylethanone (4NF) and its protective effect against DNA damage using the mouse bone marrow micronucleus test and the comet assay in mouse peripheral blood. Our results showed that this neolignan analogue had no genotoxic activity and was able to reduce induced damage both in mouse bone marrow and peripheral blood. Although the neolignan analogue 4NF was cytotoxic, it reduced cyclophosphamide-induced cytotoxicity. In conclusion, it showed no genotoxic action, but exhibited cytotoxic, antigenotoxic, and anticytotoxic activities. PMID:26554835
Thymidine analogue-sparing highly active antiretroviral therapy (HAART).
Nolan, David; Mallal, Simon
2003-02-01
The use of alternative nucleoside reverse transcriptase inhibitors (NRTIs) to the thymidine analogues stavudine (d4T) and zidovudine(ZDV) has been advocated as a means of limiting long-term NRTI-associated toxicity, particularly the development of lipoatrophy or fat wasting. This approach reflects an increasing knowledge of the distinct toxicity profiles of NRTI drugs. However, recent clinical trials have demonstrated that the use of thymidine analogue NRTIs and newer alternative backbone NRTIs, such as tenofovir (TNF) and abacavir (ABC), is associated with comparable short-term efficacy and tolerability. Given the importance of toxicity profile differences in determining clinical management, it is important to recognise that d4T and ZDV cary significantly different risks for long-term NRTI toxicity. Recognising that all NRTIs, including thymidine analogues, have individual toxicity profiles provides a more appropriate basis for selecting optimal antiretroviral therapy. The safety and efficacy of TNF and ABC are also reviewed here, although the available data provide only limited knowledge of the long-term effects of these drugs in terms of toxicity and antiviral durability.
Introduction (Special Issue on Scientific Balloon Capabilities and Instrumentation)
NASA Technical Reports Server (NTRS)
Gaskin, Jessica A.; Smith, I. S.; Jones, W. V.
2014-01-01
In 1783, the Montgolfier brothers ushered in a new era of transportation and exploration when they used hot air to drive an un-tethered balloon to an altitude of 2 km. Made of sackcloth and held together with cords, this balloon challenged the way we thought about human travel, and it has since evolved into a robust platform for performing novel science and testing new technologies. Today, high-altitude balloons regularly reach altitudes of 40 km, and they can support payloads that weigh more than 3,000 kg. Long-duration balloons can currently support mission durations lasting 55 days, and developing balloon technologies (i.e. Super-Pressure Balloons) are expected to extend that duration to 100 days or longer; competing with satellite payloads. This relatively inexpensive platform supports a broad range of science payloads, spanning multiple disciplines (astrophysics, heliophysics, planetary and earth science.) Applications extending beyond traditional science include testing new technologies for eventual space-based application and stratospheric airships for planetary applications.
NASA Technical Reports Server (NTRS)
Horn, W. J.; Carlson, L. A.
1983-01-01
A FORTRAN computer program called THERMTRAJ is presented which can be used to compute the trajectory of high altitude scientific zero pressure balloons from launch through all subsequent phases of the balloon flight. In addition, balloon gas and film temperatures can be computed at every point of the flight. The program has the ability to account for ballasting, changes in cloud cover, variable atmospheric temperature profiles, and both unconditional valving and scheduled valving of the balloon gas. The program was verified for an extensive range of balloon sizes (from 0.5 to 41.47 million cubic feet). Instructions on program usage, listing of the program source deck, input data and printed and plotted output for a verification case are included.
Schober, Karsten E; Rhinehart, Jaylyn; Kohnken, Rebecca; Bonagura, John D
2017-12-01
Combined cutting balloon and high-pressure balloon dilation was performed in a dog with a double-chambered right ventricle and severe infundibular stenosis of the right ventricular outflow tract. The peak systolic pressure gradient across the stenosis decreased by 65% after dilation (from 187 mmHg before to 66 mmHg after) affirming the intervention as successful. However, early re-stenosis occurred within 3 months leading to exercise intolerance, exercise-induced syncope, and right-sided congestive heart failure. Cutting balloon followed by high-pressure balloon dilation provided temporary but not long-term relief of right ventricular obstruction in this dog. Copyright © 2017 Elsevier B.V. All rights reserved.
Anti-fibrinolytic use for minimising perioperative allogeneic blood transfusion
Henry, David A; Carless, Paul A; Moxey, Annette J; O’Connell, Dianne; Stokes, Barrie J; Fergusson, Dean A; Ker, Katharine
2014-01-01
Background Concerns regarding the safety of transfused blood have led to the development of a range of interventions to minimise blood loss during major surgery. Anti-fibrinolytic drugs are widely used, particularly in cardiac surgery, and previous reviews have found them to be effective in reducing blood loss, the need for transfusion, and the need for re-operation due to continued or recurrent bleeding. In the last few years questions have been raised regarding the comparative performance of the drugs. The safety of the most popular agent, aprotinin, has been challenged, and it was withdrawn from world markets in May 2008 because of concerns that it increased the risk of cardiovascular complications and death. Objectives To assess the comparative effects of the anti-fibrinolytic drugs aprotinin, tranexamic acid (TXA), and epsilon aminocaproic acid (EACA) on blood loss during surgery, the need for red blood cell (RBC) transfusion, and adverse events, particularly vascular occlusion, renal dysfunction, and death. Search methods We searched: the Cochrane Injuries Group’s Specialised Register (July 2010), Cochrane Central Register of Controlled Trials (The Cochrane Library 2010, Issue 3), MEDLINE (Ovid SP) 1950 to July 2010, EMBASE (Ovid SP) 1980 to July 2010. References in identified trials and review articles were checked and trial authors were contacted to identify any additional studies. The searches were last updated in July 2010. Selection criteria Randomised controlled trials (RCTs) of anti-fibrinolytic drugs in adults scheduled for non-urgent surgery. Eligible trials compared anti-fibrinolytic drugs with placebo (or no treatment), or with each other. Data collection and analysis Two authors independently assessed trial quality and extracted data. This version of the review includes a sensitivity analysis excluding trials authored by Prof. Joachim Boldt. Main results This review summarises data from 252 RCTs that recruited over 25,000 participants. Data from the head-to-head trials suggest an advantage of aprotinin over the lysine analogues TXA and EACA in terms of reducing perioperative blood loss, but the differences were small. Compared to control, aprotinin reduced the probability of requiring RBC transfusion by a relative 34% (relative risk [RR] 0.66, 95% confidence interval [CI] 0.60 to 0.72). The RR for RBC transfusion with TXA was 0.61 (95% CI 0.53 to 0.70) and was 0.81 (95% CI 0.67 to 0.99) with EACA. When the pooled estimates from the head-to-head trials of the two lysine analogues were combined and compared to aprotinin alone, aprotinin appeared more effective in reducing the need for RBC transfusion (RR 0.90; 95% CI 0.81 to 0.99). Aprotinin reduced the need for re-operation due to bleeding by a relative 54% (RR 0.46, 95% CI 0.34 to 0.62). This translates into an absolute risk reduction of 2% and a number needed-to-treat (NNT) of 50 (95% CI 33 to 100). A similar trend was seen with EACA (RR 0.32, 95% CI 0.11 to 0.99) but not TXA (RR 0.80, 95% CI 0.55 to 1.17). The blood transfusion data were heterogeneous and funnel plots indicate that trials of aprotinin and the lysine analogues may be subject to publication bias. When compared with no treatment aprotinin did not increase the risk of myocardial infarction (RR 0.87, 95% CI 0.69 to 1.11), stroke (RR 0.82, 95% CI 0.44 to 1.52), renal dysfunction (RR 1.10, 95% CI 0.79 to 1.54) or overall mortality (RR 0.81, 95% CI 0.63 to 1.06). Similar trends were seen with the lysine analogues, but data were sparse. These data conflict with the results of recently published non-randomised studies, which found increased risk of cardiovascular complications and death with aprotinin. There are concerns about the adequacy of reporting of uncommon events in the small clinical trials included in this review. When aprotinin was compared directly with either, or both, of the two lysine analogues it resulted in a significant increase in the risk of death (RR 1.39, 95% CI 1.02, 1.89), and a non-significant increase in the risk of myocardial infarction (RR 1.11 95% CI 0.82, 1.50). Most of the data contributing to this added risk came from a single study - the BART trial (2008). Authors’ conclusions Anti-fibrinolytic drugs provide worthwhile reductions in blood loss and the receipt of allogeneic red cell transfusion. Aprotinin appears to be slightly more effective than the lysine analogues in reducing blood loss and the receipt of blood transfusion. However, head to head comparisons show a lower risk of death with lysine analogues when compared with aprotinin. The lysine analogues are effective in reducing blood loss during and after surgery, and appear to be free of serious adverse effects. PMID:21412876
Morphological characterization of selected balloon films and its effects on balloon performances
NASA Technical Reports Server (NTRS)
Said, Magdi A.
1994-01-01
Morphological characterization of several polyethylene balloon films have been studied using various techniques. The objective is to determine, if any, differentiating structural or morphological features that can be related to the performance of these balloon film materials. The results of the study indicate that the films are composed of either linear low denstiy polyethylene (LLDPE) or low density polyethylene (LDPE). A selective examination of these data imply that films limited degree of branching and larger crystallites size (same % crystallinity) showed good mechanical properties that appear to correlate with their high level of success in balloon flights.
2002-12-05
KENNEDY SPACE CENTER, FLA. - Stephen Ezell, meteorological systems operator at Weather Station A, Cape Canaveral Air Force Station, gets ready to release a weather balloon. Such balloons are released twice a day. The package in Ezell's hand is a radio sonde that collects temperature and humidity data as the balloon rises. The data is released to agencies nationwide, including the 45th Space Wing, which uses the data for its daily weather reports. The weather station provides additional data to NASA for launches -- releasing 12 balloons in eight hours prior to liftoff - and landings - releasing 5 balloons in six and a half hours before expected touchdown.
2002-12-05
KENNEDY SPACE CENTER, FLA. -- Stephen Ezell, meteorological systems operator at Weather Station A, Cape Canaveral Air Force Station, releases a weather balloon. Such balloons are released twice a day. The package at the bottom is a radio sonde that collects temperature and humidity data as the balloon rises. The data is released to agencies nationwide, including the 45th Space Wing, which uses the data for its daily weather reports. The weather station provides additional data to NASA for launches -- releasing 12 balloons in eight hours prior to liftoff - and landings - releasing 5 balloons in six and a half hours before expected touchdown.
2002-12-05
KENNEDY SPACE CENTER, FLA. - Stephen Ezell, meteorological systems operator at Weather Station A, Cape Canaveral Air Force Station, gets ready to release a weather balloon. Such balloons are released twice a day. The package in Ezell's hand is a radio sonde that collects temperature and humidity data as the balloon rises. The data is released to agencies nationwide, including the 45th Space Wing, which uses the data for its daily weather reports. The weather station provides additional data to NASA for launches -- releasing 12 balloons in eight hours prior to liftoff - and landings - releasing 5 balloons in six and a half hours before expected touchdown.
Yellow Balloon in a Briar Patch.
ERIC Educational Resources Information Center
Cooper, Frank; Fitzmaurice, Robert W.
1978-01-01
As part of a meteorology unit, sixth grade science students launched helium balloons with attached return postcards. This article describes Weather Service monitoring of the balloons and postcard return results. (MA)
21 CFR 874.4100 - Epistaxis balloon.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...
Pitocco, D; Rizzi, A; Scavone, G; Tanese, L; Zaccardi, F; Manto, A; Ghirlanda, G
2013-09-01
In western countries, diabetes mellitus, because of macrovascular and microvascular complications related to it, is still an important cause of death. Patients with type 1 diabetes mellitus (T1DM) have a six-time higher risk of mortality than healthy patients. Since the Diabetes Control and Complications Trial (DCCT) established how an intensive therapy is necessary to prevent diabetes mellitus complications, many studies have been conducted to understand which method is able to reach an optimal metabolic control. In the past 30 years continuous subcutaneous insulin infusion established/introduced as a validate alternative to multiple daily injections. Several trials demonstrated that, when compared to MDI, CSII brings to a better metabolic control, in terms of a reduction of glycated hemoglobin and blood glucose variability, hypoglycemic episodes and improvement in quality of life. Because of their pharmacokinetic and pharmacodynamic characteristics, rapid-action insulin analogues are imposed as best insulin to be used in CSII. The rapid onset and the fast reached peak make them better mimic the way how pancreas secretes insulin. CSII by pump is not free from issues. Catheter occlusions, blockages, clogs can arrest insulin administration. The consequent higher levels of glycemic values, can easily bring to the onset of ketoacidosis, with an high risk for patients' life. Aspart is a rapid analogue obtained by aminoacidic substitution. It is as effective as lispro and glulisine in gaining a good metabolic control and even better in reducing glucose variability. Some studies tried to compare rapid analogues in terms of stability. Obtained data are controversial. An in vivo study evidenced higher stability or glulisine, while studies in vitro highlighted a higher safety of aspart. Nowadays it is not possible to assess which analogues is safer. When the infusion set is changed every 48 hours equivalent rates of occlusions have been observed.
Altayyar, Sultan; Al-Omari, Awad; Alqahtani, Abdulrahman M; Rochwerg, Bram; Alnasser, Sami; Alqahtani, Zuhoor; Fox-Robichaud, Alison; Alhazzani, Waleed
2015-01-01
Cardiogenic shock is associated with significant mortality, particularly when caused by myocardial infarction. Intraaortic balloon pump (IABP) is the primary hemodynamic adjunct in patients with cardiogenic shock; however, evidence suggests that IABP may not improve mortality in this population. We conducted an electronic search of the Medline, EMBASE, and Cochrane trial registry databases. Two reviewers independently screened citations and identified eligible trials. The same reviewers abstracted data independently. We pooled the data using a fixed effect model and reported dichotomous outcomes as risk ratios (RRs) with 95% confidence intervals (CIs). Subsequently, we used the GRADE approach to judge the quality of evidence. We included 4 randomized trials with 735 patients. The use of IABP did not reduce the risk of death in patients with cardiogenic shock secondary to cardiac ischemia when compared with usual care (RR, 0.94; 95% CI, 0.79-1.13; P = 0.52; I² = 0%; moderate confidence). The use of IABP was not associated with an increased risk of stroke (RR, 0.77; 95% CI 0.22-2.69; P = 0.68; I² = 48%; very low confidence), limb ischemia (RR, 1.24; 95% CI, 0.59-2.59; P = 0.58; I² = 0%; low confidence), or major bleeding (RR, 0.76; 95% CI, 0.34-1.72; P = 0.52; I² = 0%; low confidence). The use of IABP in patients with cardiogenic shock complicating myocardial ischemia does not reduce mortality (moderate confidence) and is not associated with a higher risk of complications (very low to low confidence). The results should be interpreted with caution owing to limitations such as imprecision, risk of bias, and clinical heterogeneity.
Park, Jun-Bean; Hwang, In-Chang; Lee, Whal; Han, Jung-Kyu; Kim, Chi-Hoon; Lee, Seung-Pyo; Yang, Han-Mo; Park, Eun-Ah; Kim, Hyung-Kwan; Chiam, Paul T L; Kim, Yong-Jin; Koo, Bon-Kwon; Sohn, Dae-Won; Ahn, Hyuk; Kang, Joon-Won; Park, Seung-Jung; Kim, Hyo-Soo
2018-05-15
Limited data exist regarding the impact of aortic valve calcification (AVC) eccentricity on the risk of paravalvular regurgitation (PVR) and response to balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR). We investigated the prognostic value of AVC eccentricity in predicting the risk of PVR and response to BPD in patients undergoing TAVR. We analyzed 85 patients with severe aortic stenosis who underwent self-expandable TAVR (43 women; 77.2±7.1years). AVC was quantified as the total amount of calcification (total AVC load) and as the eccentricity of calcium (EoC) using calcium volume scoring with contrast computed tomography angiography (CTA). The EoC was defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method). Total AVC load and bi-partition EoC, but not leaflet-based EoC, were significant predictors for the occurrence of ≥moderate PVR, and bi-partition EoC had a better predictive value than total AVC load (area under the curve [AUC]=0.863 versus 0.760, p for difference=0.006). In multivariate analysis, bi-partition EoC was an independent predictor for the risk of ≥moderate PVR regardless of perimeter oversizing index. The greater bi-partition EoC was the only significant parameter to predict poor response to BPD (AUC=0.775, p=0.004). Pre-procedural assessment of AVC eccentricity using CTA as "bi-partition EoC" provides useful predictive information on the risk of significant PVR and response to BPD in patients undergoing TAVR with self-expandable valves. Copyright © 2017 Elsevier B.V. All rights reserved.
Atmospheric Electricity and Tethered Aerostats, Volume 2
1976-05-11
vs Altitude (Non- conducting or Conducting Tethers...Effect of Corona Charge Plume 15 3.1 Tether Current vs Balloon Altitude , BJ+3 - 25 Sep 73 20 3.2 Tether Current vs Balloon Altitude , Baldy - 17 Oct 73 21...3.3 Tether Current vs Balloon Altitude , Baldy - 31 Oct 73 22 3.4 Tether Current vs Balloon Altitude , Baldy - 2 Nov 73 23 3.5 Tether Current vs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsi, Wen C.; Fagundes, Marcio; Zeidan, Omar
Purpose: To present a practical image-guided method to position an endorectal balloon that improves in vivo thermoluminiscent dosimeter (TLD) measurements of rectal doses in proton therapy for prostate cancer. Methods: TLDs were combined with endorectal balloons to measure dose at the anterior rectal wall during daily proton treatment delivery. Radiopaque metallic markers were employed as surrogates for balloon position reproducibility in rotation and translation. The markers were utilized to guide the balloon orientation during daily treatment employing orthogonal x-ray image-guided patient positioning. TLDs were placed at the 12 o'clock position on the anterior balloon surface at the midprostatic plane. Markersmore » were placed at the 3 and 9 o'clock positions on the balloon to align it with respect to the planned orientation. The balloon rotation along its stem axis, referred to as roll, causes TLD displacement along the anterior-posterior direction. The magnitude of TLD displacement is revealed by the separation distance between markers at opposite sides of the balloon on sagittal x-ray images. Results: A total of 81 in vivo TLD measurements were performed on six patients. Eighty-three percent of all measurements (65 TLD readings) were within +5% and -10% of the planning dose with a mean of -2.1% and a standard deviation of 3.5%. Examination of marker positions with in-room x-ray images of measured doses between -10% and -20% of the planned dose revealed a strong correlation between balloon roll and TLD displacement posteriorly from the planned position. The magnitude of the roll was confirmed by separations of 10-20 mm between the markers which could be corrected by manually adjusting the balloon position and verified by a repeat x-ray image prior to proton delivery. This approach could properly correct the balloon roll, resulting in TLD positioning within 2 mm along the anterior-posterior direction. Conclusions: Our results show that image-guided TLD-based in vivo dosimetry for rectal dose verification can be perfomed reliably and reproducibly for proton therapy in prostate cancer.« less
Hsi, Wen C; Fagundes, Marcio; Zeidan, Omar; Hug, Eugen; Schreuder, Niek
2013-05-01
To present a practical image-guided method to position an endorectal balloon that improves in vivo thermoluminiscent dosimeter (TLD) measurements of rectal doses in proton therapy for prostate cancer. TLDs were combined with endorectal balloons to measure dose at the anterior rectal wall during daily proton treatment delivery. Radiopaque metallic markers were employed as surrogates for balloon position reproducibility in rotation and translation. The markers were utilized to guide the balloon orientation during daily treatment employing orthogonal x-ray image-guided patient positioning. TLDs were placed at the 12 o'clock position on the anterior balloon surface at the midprostatic plane. Markers were placed at the 3 and 9 o'clock positions on the balloon to align it with respect to the planned orientation. The balloon rotation along its stem axis, referred to as roll, causes TLD displacement along the anterior-posterior direction. The magnitude of TLD displacement is revealed by the separation distance between markers at opposite sides of the balloon on sagittal x-ray images. A total of 81 in vivo TLD measurements were performed on six patients. Eighty-three percent of all measurements (65 TLD readings) were within +5% and -10% of the planning dose with a mean of -2.1% and a standard deviation of 3.5%. Examination of marker positions with in-room x-ray images of measured doses between -10% and -20% of the planned dose revealed a strong correlation between balloon roll and TLD displacement posteriorly from the planned position. The magnitude of the roll was confirmed by separations of 10-20 mm between the markers which could be corrected by manually adjusting the balloon position and verified by a repeat x-ray image prior to proton delivery. This approach could properly correct the balloon roll, resulting in TLD positioning within 2 mm along the anterior-posterior direction. Our results show that image-guided TLD-based in vivo dosimetry for rectal dose verification can be perfomed reliably and reproducibly for proton therapy in prostate cancer.
Medical judgement analogue studies with applications to spaceflight crew medical officer
McCarroll, Michele L; Ahmed, Rami A; Schwartz, Alan; Gothard, Michael David; Atkinson, Steven Scott; Hughes, Patrick; Brito, Jose Cepeda; Assad, Lori; Myers, Jerry; George, Richard L
2017-01-01
Background The National Aeronautics and Space Administration (NASA) developed plans for potential emergency conditions from the Exploration Medical Conditions List. In an effort to mitigate conditions on the Exploration Medical Conditions List, NASA implemented a crew medical officer (CMO) designation for eligible astronauts. This pilot study aims to add knowledge that could be used in the Integrated Medical Model. Methods An analogue population was recruited for two categories: administrative physicians (AP) representing the physician CMOs and technical professionals (TP) representing the non-physician CMOs. Participants completed four medical simulations focused on abdominal pain: cholecystitis (CH) and renal colic (RC) and chest pain: cardiac ischaemia (STEMI; ST-segment elevation myocardial infarction) and pneumothorax (PX). The Medical Judgment Metric (MJM) was used to evaluate medical decision making. Results There were no significant differences between the AP and TP groups in age, gender, race, ethnicity, education and baseline heart rate. Significant differences were noted in MJM average rater scores in AP versus TP in CH: 13.0 (±2.25), 4.5 (±0.48), p=<0.001; RC: 12.3 (±2.66), 4.8 (±0.94); STEMI: 12.1 (±3.33), 4.9 (±0.56); and PX: 13.5 (±2.53), 5.3 (±1.01), respectively. Discussion There could be a positive effect on crew health risk by having a physician CMO. The MJM demonstrated the ability to quantify medical judgement between the two analogue groups of spaceflight CMOs. Future studies should incorporate the MJM in a larger analogue population study to assess the medical risk for spaceflight crewmembers. PMID:29354280
Medical judgement analogue studies with applications to spaceflight crew medical officer.
McCarroll, Michele L; Ahmed, Rami A; Schwartz, Alan; Gothard, Michael David; Atkinson, Steven Scott; Hughes, Patrick; Brito, Jose Cepeda; Assad, Lori; Myers, Jerry; George, Richard L
2017-10-01
The National Aeronautics and Space Administration (NASA) developed plans for potential emergency conditions from the Exploration Medical Conditions List. In an effort to mitigate conditions on the Exploration Medical Conditions List, NASA implemented a crew medical officer (CMO) designation for eligible astronauts. This pilot study aims to add knowledge that could be used in the Integrated Medical Model. An analogue population was recruited for two categories: administrative physicians (AP) representing the physician CMOs and technical professionals (TP) representing the non-physician CMOs. Participants completed four medical simulations focused on abdominal pain: cholecystitis (CH) and renal colic (RC) and chest pain: cardiac ischaemia (STEMI; ST-segment elevation myocardial infarction) and pneumothorax (PX). The Medical Judgment Metric (MJM) was used to evaluate medical decision making. There were no significant differences between the AP and TP groups in age, gender, race, ethnicity, education and baseline heart rate. Significant differences were noted in MJM average rater scores in AP versus TP in CH: 13.0 (±2.25), 4.5 (±0.48), p=<0.001; RC: 12.3 (±2.66), 4.8 (±0.94); STEMI: 12.1 (±3.33), 4.9 (±0.56); and PX: 13.5 (±2.53), 5.3 (±1.01), respectively. There could be a positive effect on crew health risk by having a physician CMO. The MJM demonstrated the ability to quantify medical judgement between the two analogue groups of spaceflight CMOs. Future studies should incorporate the MJM in a larger analogue population study to assess the medical risk for spaceflight crewmembers.
Apple, Marc; Waksman, Ron; Chan, Rosanna C; Vodovotz, Yoram; Fournadjiev, Jana; Bass, Bill G
2002-08-06
Ionizing radiation administered intraluminally via catheter-based systems using solid beta and gamma sources or liquid-filled balloons has shown reduction in the neointima formation after injury in the porcine model. We propose a novel system that uses a 133-Xenon (133Xe) radioactive gas-filled balloon catheter system. Overstretch balloon injury was performed in the coronary arteries of 33 domestic pigs. A novel 133Xe radioactive gas-filled balloon (3.5/45 mm) was positioned to overlap the injured segment with margins. After vacuum was obtained in the balloon catheter, approximately 2.5 cc of 133Xe gas was injected to fill the balloon. Doses of 0, 7.5, 15, and 30 Gy were delivered to a distance of 0.25 mm from the balloon surface. The dwell time ranged from 1.0 to 4.0 minutes, depending on the dose. Localization of 133Xe in the balloon was verified by a gamma camera. The average activity in a 3.5/45-mm balloon was measured at 67.7+/-12.1 mCi, and the total diffusion loss of the injected dose was 0.26% per minute of the injected dose. Bedside radiation exposure measured between 2 and 6 mR/h, and the shallow dose equivalent was calculated as 0.037 mrem per treatment. Histomorphometric analysis at 2 weeks showed inhibition of the intimal area (intimal area corrected for medial fracture length [IA/FL]) in the irradiated segments of 0.26+/-0.08 with 30 Gy, 0.07+/-0.24 with 15 Gy, and 0.12+/-0.89 with 7.5 Gy versus 0.76+/-0.08 with control P<0.001. 133Xe gas-filled balloon is feasible and effective in the reduction of neointima formation in the porcine model and safe for use in coronary arteries.
Shindo, Ryosuke; Yonemoto, Naohiro; Yamamoto, Yuriko; Kasai, Junko; Kasai, Michi; Miyagi, Etsuko
2017-01-01
Objective To compare the efficacy and safety of hygroscopic dilators and balloon catheters for ripening of the cervix in induction of labor. Study design This retrospective, observational study used data from the Successive Pregnancy Birth Registry System of the Japan Society of Obstetrics and Gynecology from 2012 to 2014. Nulliparous women in whom labor was induced by mechanical methods of cervical ripening at term were enrolled. The eligible women were divided into dilator, balloon <40 mL, balloon ≧40 mL, and overlapping groups. Results The groups included 4645, 4100, 6615, and 1992 women, respectively. In the overlapping group, which included the women in whom delivery was most difficult, the vaginal delivery rate was lower and the intrauterine infection and neonatal mortality rates were higher than those in the dilator group. No difference in the vaginal delivery rate was observed among the dilator, balloon <40 mL, and balloon ≧40 mL groups (74.6%, 72.3%, and 73.8%, respectively; p>0.05). The vaginal instrumental delivery rate was higher in the two-balloon groups than in the dilator group. The volume of intrapartum hemorrhage was lowest in the dilator group. No significant difference in the frequencies of uterine rupture and intrauterine infection were observed among the dilator and two-balloon groups. With regard to neonatal outcomes, the frequency of a low Apgar score was statistically significantly lower in the dilator group than in the two-balloon groups. Moreover, the frequency of neonatal death tended to be lower in the dilator group than in the two-balloon groups. Conclusion With regard to cervical ripening for labor induction in nulliparous women at term, the vaginal delivery rate on using a dilator and on using a balloon seems to be equivalent. Concerning maternal complications and neonatal outcomes, cervical ripening with hygroscopic dilators in labor induction might be safer. PMID:29272277
NASA Astrophysics Data System (ADS)
Vial, F.; Hertzog, A.; Mechoso, C. R.; Basdevant, C.; Cocquerez, P.; Dubourg, V.; Nouel, F.
2001-10-01
In the late southern winter of 1998, Center National d'Études Spatiales (CNES), the French Space Agency, released six 10-m-diameter, superpressure balloons from a location near Quito, Ecuador. Three balloons collapsed soon after launching, but the remaining three drifted westward for a few weeks at altitudes between 19 and 20 km. Two of those balloons crossed the Pacific Ocean before falling above the ``maritime continent,'' while the other completed a revolution around the Earth and crossed the Pacific for a second time before its final fall. Despite the small number and the relatively short duration of the flights, the balloons provided a unique in situ data set for the lower equatorial stratosphere. This part 1 of a two-part paper describes this data set and analyzes outstanding features in the planetary scales. Part 2 focuses on gravity-wave scale. It is argued that balloon trajectories over the Pacific are primarily determined by the westward drift during the easterly phase of the equatorial quasi-biennial oscillation (QBO) and the meridional velocity field of a mixed Rossby-gravity (Yanai) wave with an apparent period of 4 days and zonal wave number 4. This wave appears to have two episodes of amplification during the balloon flights. It is also argued that the balloons show evidence of oscillations with periods between 2 and 4 days and of a Kelvin wave with an apparent period close to 10 days and zonal wave number 1. In this way, the balloon behavior provided a pictorial view of air parcel trajectory in the equatorial lower stratosphere. It is stated that larger balloon campaigns can provide excellent in situ data sets for studies on the dynamics and composition of the middle atmosphere.
Turk, Marvee; Gupta, Vishal; Fischell, Tim A
2010-03-01
There have been reports of serious complications related to difficulty removing the deflated Taxus stent delivery balloon after stent deployment. The purpose of this study was to determine whether the Taxus SIBS polymer was "sticky" and associated with an increase in the force required to remove the stent delivery balloon after stent deployment, using a quantitative, ex-vivo model. Balloon-polymer-stent interactions during balloon withdrawal were measured with the Taxus Liberté, Liberté bare-metal stent (BMS; no polymer = control), the Cordis Cypher drug-eluting stent (DES; PEVA/PBMA polymer) and the BX Velocity (no polymer). We quantitatively measured the force required to remove the deflated stent delivery balloon from each of these stents in simulated vessels at 37 degrees C in a water bath. Balloon withdrawal forces were measured in straight (0 degree curve), mildly curved (20 degree curve) and moderately curved (40 degree curve) simulated vessel segments. The average peak force required to remove the deflated balloon catheter from the Taxus Liberté DES, the Liberté BMS, the Cypher DES, and the Bx Velocity BMS were similar in straight segments, but were much greater for the Taxus Liberté in the moderately curved segments (1.4 lbs vs. 0.11 lbs, 0.11 lbs and 0.12 lbs, respectively; p < 0.0001). The SIBS polymer of the Taxus Liberté DES appears to be "sticky" and is associated with high forces required to withdraw the deflated balloon from the deployed stent in curved segments. This withdrawal issue may help to explain the clinical complications that have been reported with this device.
Balloon dilation of the eustachian tube for dilatory dysfunction: A randomized controlled trial.
Poe, Dennis; Anand, Vijay; Dean, Marc; Roberts, William H; Stolovitzky, Jose Pablo; Hoffmann, Karen; Nachlas, Nathan E; Light, Joshua P; Widick, Mark H; Sugrue, John P; Elliott, C Layton; Rosenberg, Seth I; Guillory, Paul; Brown, Neil; Syms, Charles A; Hilton, Christopher W; McElveen, John T; Singh, Ameet; Weiss, Raymond L; Arriaga, Moises A; Leopold, John P
2018-05-01
To assess balloon dilation of the Eustachian tube with Eustachian tube balloon catheter in conjunction with medical management as treatment for Eustachian tube dilatory dysfunction. In this prospective, multicenter, randomized, controlled trial, we assigned, in a 2:1 ratio, patients age 22 years and older with Eustachian tube dilatory dysfunction refractory to medical therapy to undergo balloon dilation of the Eustachian tube with balloon catheter in conjunction with medical management or medical management alone. The primary endpoint was normalization of tympanogram at 6 weeks. Additional endpoints were normalization of Eustachian Tube Dysfunction Questionaire-7 symptom scores, positive Valsalva maneuver, mucosal inflammation, and safety. Primary efficacy results demonstrated superiority of balloon dilation of the Eustachian tube with balloon catheter + medical management compared to medical management alone. Tympanogram normalization at 6-week follow-up was observed in 51.8% (72/139) of investigational patients versus 13.9% (10/72) of controls (P < .0001). Tympanogram normalization in the treatment group was 62.2% after 24 weeks. Normalization of Eustachian Tube Dysfunction Questionaire-7 Symptom scores at 6-week follow-up was observed in 56.2% (77/137) of investigational patients versus 8.5% (6/71) controls (P < .001). The investigational group also demonstrated substantial improvement in both mucosal inflammation and Valsalva maneuver at 6-week follow-up compared to controls. No device- or procedure-related serious adverse events were reported for those who underwent balloon dilation of the Eustachian tube. This study demonstrated superiority of balloon dilation of the Eustachian tube with balloon catheter + medical management compared to medical management alone to treat Eustachian tube dilatory dysfunction in adults. 1b. Laryngoscope, 128:1200-1206, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Karanasos, Antonios; Van Mieghem, Nicolas; Bergmann, Martin W; Hartman, Eline; Ligthart, Jurgen; van der Heide, Elco; Heeger, Christian-H; Ouhlous, Mohamed; Zijlstra, Felix; Regar, Evelyn; Daemen, Joost
2015-07-01
Renal denervation is a new treatment considered for several possible indications. As new systems are introduced, the incidence of acute renal artery wall injury with relation to the denervation method is unknown. We investigated the acute repercussion of renal denervation on the renal arteries of patients treated with balloon-based and nonballoon-based denervation systems by quantitative angiography, intravascular ultrasound, and optical coherence tomography (OCT). Twenty-five patients (50 renal arteries) underwent bilateral renal denervation with 5 different systems, 3 of which balloon-based (Paradise [n=5], Oneshot [n=6], and Vessix V2 [n=5)]) and 2 nonballoon-based (Symplicity [n=6] and EnligHTN [n=3]). Analysis included quantitative angiography and morphometric intravascular ultrasound measurements pre and post procedure and assessment of vascular trauma (dissection, edema, or thrombus) by OCT after denervation. A significant reduction in lumen size by quantitative angiography and intravascular ultrasound was observed in nonballoon denervation but not in balloon denervation. By postdenervation OCT, dissection was seen in 14 arteries (32.6%). The percentage of frames with dissection was higher in balloon-based denervation catheters. Thrombus and edema were detected in 35 (81.4%) and 32 (74.4%) arteries, respectively. In arteries treated with balloon-based denervation that had dissection by OCT, the balloon/artery ratio was higher (1.24 [1.17-1.32] versus 1.10 [1.04-1.18]; P<0.01). A varying extent of vascular injury was observed after renal denervation in all systems; however, different patterns were identified in balloon-based and in nonballoon-based denervation systems. In balloon denervation, the presence of dissections by OCT was associated with a higher balloon/artery ratio. © 2015 American Heart Association, Inc.
Static and quasi-static analysis of lobed-pumpkin balloon
NASA Astrophysics Data System (ADS)
Nakashino, Kyoichi; Sasaki, Makoto; Hashimoto, Satoshi; Saito, Yoshitaka; Izutsu, Naoki
The present study is motivated by the need to improve design methodology for super pressure balloon with 3D gore design concept, currently being developed at the Scientific Balloon Center of ISAS/JAXA. The distinctive feature of the 3-D gore design is that the balloon film has excess materials not only in the circumferential direction but also in the meridional direction; the meridional excess is gained by attaching the film boundaries to the corresponding tendons of a shorter length with a controlled shortening rate. The resulting balloon shape is a pumpkin-like shape with large bulges formed between adjacent tendons. The balloon film, when fully inflated, develops wrinkles in the circumferential direction over its entire region, so that the stresses in the film are limited to a small amount of uniaxial tension in the circumferential direction while the high meridional loads are carried by re-enforced tendons. Naturally, the amount of wrinkling in the film is dominated by the shortening rate between the film boundaries and the tendon curve. In the 3-D gore design, as a consequence, the shortening rate becomes a fundamental design parameter along with the geometric parameters of the gore. In view of this, we have carried out a series of numerical study of the lobed-pumpkin balloon with varying gore geometry as well as with varying shortening rate. The numerical simula-tions were carried out with a nonlinear finite element code incorporating the wrinkling effect. Numerical results show that there is a threshold value for the shortening rate beyond which the stresses in the balloon film increases disproportionately. We have also carried out quasi-static simulations of the inflation process of the lobed-pumpkin balloon, and have obtained asymmetric deformations when the balloon films are in uniaxial tension state.
Paton, Maria; Ashton, Lisa; Pearson, Ian; Sivananthan, Mohan
2015-01-01
Background A high number of patients do not survive primary percutaneous coronary intervention (PCI) complicated by cardiogenic shock (CS), even when assisted with intra-aortic balloon pump (IABP) counterpulsation. There is no accepted consensus on who may most benefit from IABP counterpulsation, although previous retrospective studies have reported predictors of survival for patients undergoing PCI and cardiac surgery. To date, a risk model for emergency primary PCI patients has not been ascertained. The objective of this study was to identify independent predictors for in-hospital survival, to create a standardized risk model to predict patients who may require IABP insertion during primary PCI. Method Retrospective data were from 165 patients who had undergone primary PCI with IABP due to CS complicating acute myocardial infarction (AMI), from September 2007 to 2010, and underwent logistic regression analysis, to evaluate the incremental risk factors associated with survival. Results The overall in-hospital mortality was 32.1% (53 patients). The incremental independent predictors for in-hospital survival were: patient age of less than 60 years (OR: 0.303, 95% CI: 0.11 - 0.83, P < 0.02) and the use of IABP support alone, as opposed to in adjunction with inotropic support (OR: 3.177, 95% CI: 1.159 - 8.708, P < 0.025). Conclusion This study illustrated an age of less than 60 years, and the use of IABP alone, to be independent predictors of in-hospital survival in patients with CS complicating AMI who undergo primary PCI assisted by IABP. No specific risk model could be determined. PMID:28197255
Paton, Maria; Ashton, Lisa; Pearson, Ian; Sivananthan, Mohan
2015-12-01
A high number of patients do not survive primary percutaneous coronary intervention (PCI) complicated by cardiogenic shock (CS), even when assisted with intra-aortic balloon pump (IABP) counterpulsation. There is no accepted consensus on who may most benefit from IABP counterpulsation, although previous retrospective studies have reported predictors of survival for patients undergoing PCI and cardiac surgery. To date, a risk model for emergency primary PCI patients has not been ascertained. The objective of this study was to identify independent predictors for in-hospital survival, to create a standardized risk model to predict patients who may require IABP insertion during primary PCI. Retrospective data were from 165 patients who had undergone primary PCI with IABP due to CS complicating acute myocardial infarction (AMI), from September 2007 to 2010, and underwent logistic regression analysis, to evaluate the incremental risk factors associated with survival. The overall in-hospital mortality was 32.1% (53 patients). The incremental independent predictors for in-hospital survival were: patient age of less than 60 years (OR: 0.303, 95% CI: 0.11 - 0.83, P < 0.02) and the use of IABP support alone, as opposed to in adjunction with inotropic support (OR: 3.177, 95% CI: 1.159 - 8.708, P < 0.025). This study illustrated an age of less than 60 years, and the use of IABP alone, to be independent predictors of in-hospital survival in patients with CS complicating AMI who undergo primary PCI assisted by IABP. No specific risk model could be determined.
Tube Feeding Troubleshooting Guide
... in place. (For example, does it have a balloon, a mushroom bumper, or other internal device, or ... Frequent vomiting. • See “Nausea and Vomiting” page 3. Balloon deflates or bursts. • Be sure the balloon under ...
14 CFR 101.5 - Operations in prohibited or restricted areas.
Code of Federal Regulations, 2012 CFR
2012-01-01
... TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND... a moored balloon, kite, amateur rocket, or unmanned free balloon in a prohibited or restricted area...
14 CFR 101.5 - Operations in prohibited or restricted areas.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND... a moored balloon, kite, amateur rocket, or unmanned free balloon in a prohibited or restricted area...
14 CFR 101.5 - Operations in prohibited or restricted areas.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND... a moored balloon, kite, amateur rocket, or unmanned free balloon in a prohibited or restricted area...
14 CFR 101.5 - Operations in prohibited or restricted areas.
Code of Federal Regulations, 2014 CFR
2014-01-01
... TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND... a moored balloon, kite, amateur rocket, or unmanned free balloon in a prohibited or restricted area...
14 CFR 101.5 - Operations in prohibited or restricted areas.
Code of Federal Regulations, 2013 CFR
2013-01-01
... TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND... a moored balloon, kite, amateur rocket, or unmanned free balloon in a prohibited or restricted area...
Jagadeesan, Bharathi D; Mortazavi, Shabnam; Hunter, David W; Duran-Castro, Olga L; Snyder, Gregory B; Siedel, Glen F; Golzarian, Jafar
2014-04-01
Balloon-assisted embolization performed by delivering Onyx ethylene vinyl alcohol copolymer through a dual-lumen coaxial balloon microcatheter is a new technique for the management of peripheral vascular lesions. This technique does not require an initial reflux of Onyx to form around the tip of the microcatheter before antegrade flow of Onyx can commence. In a series of four patients who were treated with the use of this technique, the absence of significant reflux of Onyx was noted, as were excellent navigability and easy retrieval of the balloon microcatheter. However, in one patient, there was inadvertent adverse embolization of a digital artery, which was not caused by reflux of Onyx but could still be related to balloon inflation. © 2013 SIR Published by SIR All rights reserved.
Detection of Artificially Generated Seismic Signals Using Balloon-Borne Infrasound Sensors
NASA Astrophysics Data System (ADS)
Krishnamoorthy, Siddharth; Komjathy, Attila; Pauken, Michael T.; Cutts, James A.; Garcia, Raphael F.; Mimoun, David; Cadu, Alexandre; Sournac, Anthony; Jackson, Jennifer M.; Lai, Voon Hui; Bowman, Daniel C.
2018-04-01
We conducted an experiment in Pahrump, Nevada, in June 2017, where artificial seismic signals were created using a seismic hammer, and the possibility of detecting them from their acoustic signature was examined. In this work, we analyze the pressure signals recorded by highly sensitive barometers deployed on the ground and on tethers suspended from balloons. Our signal processing results show that wind noise experienced by a barometer on a free-flying balloon is lower compared to one on a moored balloon. This has never been experimentally demonstrated in the lower troposphere. While seismoacoustic signals were not recorded on the hot air balloon platform owing to operational challenges, we demonstrate the detection of seismoacoustic signals on our moored balloon platform. Our results have important implications for performing seismology in harsh surface environments such as Venus through atmospheric remote sensing.
Exhaled nitric oxide in mylar balloons: influence of storage time, humidity and temperature.
Bodini, Alessandro; Pijnenburg, Mariëlle W H; Boner, Atillio L; de Jongste, Johan C
2003-01-01
BACKGROUND: Mylar balloons are used to collect exhaled air for analysis of fractional nitric oxide concentration (FENO). AIM: We studied the effect of storage conditions on the stability of nitric oxide (NO) in mylar balloons. METHODS: Exhaled air samples and calibration gases were stored in mylar balloons at 4, 21 and 37 degrees C, with or without silica gel. NO was measured after 0, 6, 9, 24 and 48 h. Scheffe F-tests were used to compare NO values. RESULTS: NO remained stable in balloons for 9 h at all temperatures, without silica gel. NO increased between 9 and 48 h, but only with low initial FENO. Silica gel increased variability. CONCLUSIONS: FENO in mylar balloons is stable for at least 9 h. The storage temperature is not critical, but silica gel increases variability. PMID:12745548
A verified technique for calibrating space solar cells
NASA Technical Reports Server (NTRS)
Anspaugh, Bruce
1987-01-01
Solar cells have been flown on high-altitude balloons for over 24 years, to produce solar cell standards that can be used to set the intensity of solar simulators. The events of a typical balloon calibration flight are reported. These are: the preflight events, including the preflight cell measurements and the assembly of the flight cells onto the solar tracker; the activities at the National Scientific Balloon Facility in Palestine, Texas, including the preflight calibrations, the mating of the tracker and cells onto the balloon, preparations for launch, and the launch; the payload recovery, which includes tracking the balloon by aircraft, terminating the flight, and retrieving the payload. In 1985, the cells flow on the balloon were also flown on a shuttle flight and measured independently. The two measurement methods are compared and shown to agree within 1 percent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka
Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolizationmore » without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.« less
An Overview of the NASA Sounding Rocket and Balloon Programs
NASA Technical Reports Server (NTRS)
Eberspeaker, Philip J.; Smith, Ira S.
2003-01-01
The U.S. National Aeronautics and Space Administration (NASA) Sounding Rockets and Balloon Programs conduct a total of 50 to 60 missions per year in support of the NASA scientific community. These missions support investigations sponsored by NASA's Offices of Space Science, Life and Microgravity Sciences & Applications, and Earth Science. The Goddard Space Flight Center has management and implementation responsibility for these programs. The NASA Sounding Rockets Program provides the science community with payload development support, environmental testing, launch vehicles, and launch operations from fixed and mobile launch ranges. Sounding rockets continue to provide a cost-effective way to make in situ observations from 50 to 1500 km in the near-earth environment and to uniquely cover the altitude regime between 50 km and 130 km above the Earth's surface. New technology efforts include GPS payload event triggering, tailored trajectories, new vehicle configuration development to expand current capabilities, and the feasibility assessment of an ultra high altitude sounding rocket vehicle. The NASA Balloon Program continues to make advancements and developments in its capabilities for support of the scientific ballooning community. The Long Duration Balloon (LDB) is capable of providing flight durations in excess of two weeks and has had many successful flights since its development. The NASA Balloon Program is currently engaged in the development of the Ultra Long Duration Balloon (ULDB), which will be capable of providing flight times up to 100-days. Additional development efforts are focusing on ultra high altitude balloons, station keeping techniques and planetary balloon technologies.
Histopathology of balloon-dilation Eustachian tuboplasty.
Kivekäs, Ilkka; Chao, Wei-Chieh; Faquin, William; Hollowell, Monica; Silvola, Juha; Rasooly, Tali; Poe, Dennis
2015-02-01
Surgical intervention of the Eustachian tube (ET) has become increasingly common in the past decade, and balloon dilation has shown promising results in recent studies. It is unclear how balloon dilation enhances ET function. Our aim was to evaluate histological changes in the ET's mucosal lumen comparing before balloon dilation, immediately after, and postoperatively. Case series. Thirteen patients with bilateral ET dysfunction were enrolled. Biopsies of the ET mucosa were obtained just before balloon dilation; immediately after; and in three cases, 5 to 12 weeks postoperatively. Specimens were retrospectively examined under light microscopy by two pathologists blinded to the clinical information and whether specimens were pre- or postballoon dilation. Preoperative biopsies were characterized by inflammatory changes within the epithelium and submucosal layer. Immediate response to balloon dilation was thinning of the mucosa, shearing of epithelium and crush injury to the submucosa, especially to lymphocytic infiltrates. Postoperative biopsies demonstrated healthy pseudocolumnar epithelium and replacement of lymphocytic infiltrate with a thinner layer of fibrous tissue. Reduction of inflammatory epithelial changes and submucosal inflammatory infiltrate appeared to be the principal result of balloon dilation. The balloon may shear or crush portions of inflamed epithelium but usually spared the basal layer, allowing for rapid healing. Additionally, it appeared to effectively crush lymphocytes and lymphocytic follicles that may become replaced with thinner fibrous scar. Histopathology of the ET undergoing balloon dilation demonstrated effects that could reduce the overall inflammatory burden and may contribute to clinical improvement in ET function. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
The glider balloon: a useful device for the treatment of bifurcation lesions.
Briguori, Carlo; Visconti, Gabriella; Donahue, Michael; Chiariello, Giovanni Alfonso; Focaccio, Amelia
2013-10-09
Final kissing balloon dilatation (FKBD) is a recommended final step in case of treatment of bifurcation lesions by two stents approaches. Furthermore, dilatation of the side branch (SB) may be necessary following main vessel (MV) stenting. Occasionally, recrossing the stent struts with a balloon is hampered because the tip hits a stent strut. The Glider (TriReme Medical, Pleasanton, CA) is a dedicated balloon designed for crossing through struts of deployed stents toward a SB. From October 2010 to January 2012, FKBD was attempted in 236 consecutive bifurcation lesions treated in our Institution. FKBD was successfully performed by conventional balloon catheters in 221 (93.5%) lesions (Conventional group). In the remaining 15 (6.5%) lesions, where a conventional balloon failed to cross the stent strut, the Glider balloon was attempted (Glider group). The angle beta (between the axis of the MV after the branch point and the SB axis at the point of divergence) was wider in the Glider group (83±17° versus 65±27°; p=0.032). A trend toward an higher rate of the true bifurcation lesions was observed in the Glider group (93% versus 70.5%; p=0.07). The Glider balloon successfully crossed through MV stent struts toward a SB in 12 patients (80%), whereas failed in the remaining 3 patients. The Glider balloon represents an unique bail-out device which offers an effective rescue strategy for recrossing stent struts during complex bifurcation stenting. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Ohari, T.
1982-01-01
A method was developed whereby a balloon was used to carry lumber out of a forest in order to continue lumber production without destroying the natural environment and view of the forest. Emphasis was on the best shape for a logging balloon, development of a balloon logging system suitable for cutting lumber and safety plans, tests on balloon construction and development of netting, and weather of mountainous areas, especially solutions to problems caused by winds.
Assessing the Potential of Societal Verification by Means of New Media
2014-01-01
the Defense Advanced Research Projects Agency (DARPA) “Red Balloon Challenge” in 2009 by finding 10 tethered weather balloons scattered across the...Institute of Technology (MIT) managed to locate 10 weather balloons tethered at undisclosed locations across the continental United States in less than...suited for complex problem solving, and the 2009 Defense Advanced Research Projects Agency’s (DARPA) “Red Balloon Challenge” has already demonstrated
ERIC Educational Resources Information Center
Jee-Yon Lee; Hee-Soo Yoo; Jong Sook Park; Kwang-Jin Hwang; Jin Seog Kim
2005-01-01
The spontaneous mixing of helium and air in a helium-inflated balloon is described in an experiment in which the partial pressure of the gases in the balloon are determined from the mole factions and the total pressure measured in the balloon. The results described provide a model for teaching concepts of partial pressure, chemical potential, and…
NASA Technical Reports Server (NTRS)
Farley, Rodger
2007-01-01
PlanetaryBalloon Version 5.0 is a software package for the design of meridionally lobed planetary balloons. It operates in a Windows environment, and programming was done in Visual Basic 6. By including the effects of circular lobes with load tapes, skin mass, hoop and meridional stress, and elasticity in the structural elements, a more accurate balloon shape of practical construction can be determined as well as the room-temperature cut pattern for the gore shapes. The computer algorithm is formulated for sizing meridionally lobed balloons for any generalized atmosphere or planet. This also covers zero-pressure, over-pressure, and super-pressure balloons. Low circumferential loads with meridionally reinforced load tapes will produce shapes close to what are known as the "natural shape." The software allows for the design of constant angle, constant radius, or constant hoop stress balloons. It uses the desired payload capacity for given atmospheric conditions and determines the required volume, allowing users to design exactly to their requirements. The formulations are generalized to use any lift gas (or mixture of gases), any atmosphere, or any planet as described by the local acceleration of gravity. PlanetaryBalloon software has a comprehensive user manual that covers features ranging from, but not limited to, buoyancy and super-pressure, convenient design equations, shape formulation, and orthotropic stress/strain.
LISA: a java API for performing simulations of trajectories for all types of balloons
NASA Astrophysics Data System (ADS)
Conessa, Huguette
2016-07-01
LISA (LIbrarie de Simulation pour les Aerostats) is a java API for performing simulations of trajectories for all types of balloons (Zero Pressure Balloons, Pressurized Balloons, Infrared Montgolfier), and for all phases of flight (ascent, ceiling, descent). This library has for goals to establish a reliable repository of Balloons flight physics models, to capitalize developments and control models used in different tools. It is already used for flight physics study software in CNES, to understand and reproduce the behavior of balloons, observed during real flights. It will be used operationally for the ground segment of the STRATEOLE2 mission. It was developed with quality rules of "critical software." It is based on fundamental generic concepts, linking the simulation state variables to interchangeable calculation models. Each LISA model defines how to calculate a consistent set of state variables combining validity checks. To perform a simulation for a type of balloon and a phase of flight, it is necessary to select or create a macro-model that is to say, a consistent set of models to choose from among those offered by LISA, defining the behavior of the environment and the balloon. The purpose of this presentation is to introduce the main concepts of LISA, and the new perspectives offered by this library.
A balloon-borne experiment to investigate the Martian magnetic field
NASA Astrophysics Data System (ADS)
Schwingenschuh, K.; Feldhofer, H.; Koren, W.; Jernej, I.; Stachel, M.; Riedler, W.; Slamanig, H.; Auster, H.-U.; Rustenbach, J.; Fornacon, H. K.; Schenk, H. J.; Hillenmaier, O.; Haerendel, G.; Yeroshenko, Ye.; Styashkin, V.; Zaroutzky, A.; Best, A.; Scholz, G.; Russell, C. T.; Means, J.; Pierce, D.; Luhmann, J. G.
1996-03-01
The Space Research Institute of the Austrian Academy, of Sciences (Graz, Austria) in cooperation with MPE (Berlin, Germany), GFZ Potsdam (Obs. Niemegk, Germany) IZMIRAN/IOFAN (Moscow, Russian) and IGPP/UCLA (Los Angeles, USA) is designing the magnetic field experiment MAGIBAL (MAGnetic field experiment aboard a martian BALloon) to investigate the magnetic field on the surface of Mars. The dual sensor fluxgate magnetometer is part of the MARS-98/MARS-TOGETHER balloon payload. During a ten days period the balloon will float over a distance of about 2000 km at altitudes between 0 and 4 km. Due to the limited power and telemetry allocation the magnetometer can transmit only one vector per ten seconds and spectral information in the frequency range from 2 - 25 Hz. The dynamic range is +/- 2000 nT. The main scientific objectives of the experiment are: • Determination of the magnetism of the Martian rocks • Investigation of the leakage of the solar wind induced magnetosphere using the correlation between orbiter and balloon observations • Measurement of the magnetic field profile between the orbiter and the surface of Mars during the descent phase of the balloon. Terrestrial test flights with a hot air balloon were performed in order to test the original MAGIBAL equipment under balloon flight conditions.
Curie-Montgolfiere Planetary Explorers
NASA Astrophysics Data System (ADS)
Taylor, Chris Y.; Hansen, Jeremiah
2007-01-01
Hot-air balloons, also known as Montgolfiere balloons, powered by heat from radioisotope decay are a potentially useful tool for exploring planetary atmospheres and augmenting the capabilities of other exploration technologies. This paper describes the physical equations and identifies the key engineering parameters that drive radioisotope-powered balloon performance. These parameters include envelope strength-to-weight, envelope thermal conductivity, heater power-to-weight, heater temperature, and balloon shape. The design space for these parameters are shown for varying atmospheric compositions to illustrate the performance needed to build functioning ``Curie-Montgolfiere'' balloons for various planetary atmospheres. Methods to ease the process of Curie-Montgolfiere conceptual design and sizing of are also introduced.
Development of optical laser balloon and drainage from radiation vulcanized natural rubber latex
NASA Astrophysics Data System (ADS)
Shimamura, Yoshiyuki
Rubber film made of radiation vulcanized natural rubber latex (RVNRL) has better transparency and lower toxicity compared with sulfur-vulcanized latex film. Optical laser balloon (optical endoscopical balloon) and drainage were developed by using RVNRL. An endoscope was equipped with a saline-filled latex rubber balloon at its tip to displace contaminating blood, bile, or gastric contents during operative portoscopy, biliary endoscopy, or upper gastrointestinal endoscopy. The transmission of Nd-Yag laser through the balloon is 98%, higher than the sulfur-vulcanized latex rubber (75%). High transparency of the drainage bag facilitated easy observation of discharged fluids without detaching the bag from the tube.
On the feasibility of closed-loop control of intra-aortic balloon pumping
NASA Technical Reports Server (NTRS)
Clark, J. W., Jr.; Bourland, H. M.; Kane, G. R.
1973-01-01
A closed-loop control scheme for the control of intra-aortic balloon pumping has been developed and tested in dog experiments. A performance index reflecting the general objectives of balloon-assist pumping is developed and a modified steepest ascent control algorithm is utilized for the selection of a proper operating point for the balloon during its pumping cycle. This paper attempts to indicate the feasibility of closed-loop control of balloon pumping, and particularly its flexibility in achieving both diastolic augmentation of mean aortic pressure and control of the level of end-diastolic pressure (EDP) an important factor in reducing heart work.
Absorption spectrometer balloon flight and iodine investigations
NASA Technical Reports Server (NTRS)
1970-01-01
A high altitude balloon flight experiment to determine the technical feasibility of employing absorption spectroscopy to measure SO2 and NO2 gases in the earth's atmosphere from above the atmospheric ozone layer is discussed. In addition to the balloon experiment the contract includes a ground-based survey of natural I emissions from geological sources and studies of the feasibility of mapping I2 from spacecraft. This report is divided into three major sections as follows: (1) the planning engineering and execution of the balloon experiment, (2) data reduction and analysis of the balloon data, and (3) the results of the I2 phase of the contract.
2002-12-05
KENNEDY SPACE CENTER, FLA. - Stephen Ezell, meteorological systems operator at Weather Station A, Cape Canaveral Air Force Station, walks out with a weather balloon that he will release. Such balloons are released twice a day. The package in Ezell's hand is a radio sonde that collects temperature and humidity data as the balloon rises. The data is released to agencies nationwide, including the 45th Space Wing which uses the data for its daily weather reports. The weather station provides additional data to NASA for launches - releasing 12 balloons in eight hours prior to liftoff - and landings - releasing 5 balloons in six and a half hours before expected touchdown.
2002-12-05
KENNEDY SPACE CENTER, FLA. - At Weather Station A, Cape Canaveral Air Force Station, Judy Kelley, supervisor of Meteorology Operations, and Stephen Ezell, meteorological systems operator, get ready to release a weather balloon. Such balloons are released twice a day. The package at the bottom is a radio sonde that collects temperature and humidity data as the balloon rises. The data is released to agencies nationwide, including the 45th Space Wing, which uses the data for its daily weather reports. The weather station provides additional data to NASA for launches -- releasing 12 balloons in eight hours prior to liftoff - and landings - releasing 5 balloons in six and a half hours before expected touchdown.
Intragastric Balloon Treatment for Obesity: Review of Recent Studies.
Tate, Chinara M; Geliebter, Allan
2017-08-01
The FDA recently approved three intragastric balloon (IGB) devices, ReShape, ORBERA™, and Obalon for treatment of obesity. Given the high cost, complication risk, and invasiveness of bariatric surgery, IGB treatment may present a safer and lower cost option for weight reduction. IGBs are generally placed in the stomach endoscopically for up to 6 months to reduce gastric capacity, enhance feelings of fullness, and induce weight loss. The mechanism of action likely involves stimulation of gastric mechanoreceptors triggering short-acting vagal signals to brain regions implicated in satiety. Balloon efficacy may be influenced by balloon volume, patient gastric capacity, and treatment duration. This review focused on eight recent (2006-present) randomized controlled trials (RCTs) comparing percentage total body weight loss (%TBWL) between IGB and control groups including three reviewed by the FDA. %TBWL based on the reviewed studies was also compared with bariatric surgery and pharmacotherapy. Of the eight IGB studies, five had balloon treatment duration of 6 months. Efficacy at 6 months, based on a pooled weighted-mean %TBWL, was 9.7%, and the control-subtracted %TBWL was 5.6%. When one study without SDs was removed, the weighted mean %TBWL was 9.3 ± 5.7% SD, and control-subtracted %TBWL was 5.5 ± 7.8%, which was statistically greater than controls. IGB showed lower efficacy than bariatric surgery (median weight loss of 27% for Rouen-Y gastric bypass (RYGB). The control-subtracted %TBWL over 6 months of 5.5-5.6% is less than the most efficacious FDA-approved weight loss drug, Qsymia. At the recommended dose, Qsymia has a placebo-subtracted %TBWL at 6 months of approximately 6.6%. The weighted mean reported incidence of serious adverse events (SAEs) in the IGB group across all eight studies was 10.5%. Only six of the eight reviewed studies reported adverse events (AEs) in the IGB group, with a pooled reported incidence of 28.2%. Recently, the FDA reported new AEs including acute pancreatitis with ReShape and ORBERA™. Based on the available evidence, it is unlikely that IGB use will supplant other forms of obesity treatment. The estimated cost of endoscopic balloon implantation and retrieval is US $8,150. Collectively, a relatively small control-subtracted %TBWL and the potential for serious complications makes IGB unlikely to become widely adopted. Given the recent FDA warning, IGB longevity on the market is questionable.
Ioseliani, G D; Chilaia, S M
1983-02-01
A basically new design for the reversing balloon pump has been proposed for increasing the efficacy of intra-aortic balloon pumping (IABP). The device not only causes a significant increase in discharge, but also permits control of the central and peripheral circulation within the desired limits owing to back-and-forth movements (like a piston) of the balloon pump. Standard one- and two-chamber balloon pumps were compared. In addition to traditional hemodynamic and biochemical indexes, the efficacy of IABP was assessed based on electrode monitor control of PO2 and pH in the myocardium, peripheral tissues, and circulating blood. Based on 54 experiments on dogs, it was found that IABP with reversing balloon pumps in synchronous pulsation resulted in survival of 69% of the cases; PO2 and pH levels in the myocardium, tissues, and blood in the coronary sinus were close to normal, and coronary blood flow and peripheral circulation were increased. With standard one-chamber balloon pumps, the survival rate did not exceed 33.4%; PO2 and pH in the peripheral tissues reached critical levels.
The effect of pressure anisotropy on ballooning modes in tokamak plasmas
NASA Astrophysics Data System (ADS)
Johnston, A.; Hole, M. J.; Qu, Z. S.; Hezaveh, H.
2018-06-01
Edge Localised Modes are thought to be caused by a spectrum of magnetohydrodynamic instabilities, including the ballooning mode. While ballooning modes have been studied extensively both theoretically and experimentally, the focus of the vast majority of this research has been on isotropic plasmas. The prevalence of pressure anisotropy in modern tokamaks thus motivates further study of these modes. This paper presents a numerical analysis of ballooning modes in anisotropic equilibria. The investigation was conducted using the newly-developed codes HELENA+ATF and MISHKA-A, which adds anisotropic physics to equilibria and stability analysis. We have examined the impact of anisotropy on the stability of an n = 30 ballooning mode, confirming results conform to previous calculations in the isotropic limit. Growth rates of ballooning modes in equilibria with different levels of anisotropy were then calculated using the stability code MISHKA-A. The key finding was that the level of anisotropy had a significant impact on ballooning mode growth rates. For {T}\\perp > {T}| | , typical of ICRH heating, the growth rate increases, while for {T}\\perp < {T}| | , typical of neutral beam heating, the growth rate decreases.
Niehoff, Peter; Ballardini, B; Polgár, C; Major, T; Hammer, J; Richetti, A; Kovács, G
2006-06-01
Preliminary results of ultrasound studies do exist in the literature on the successful use of the MammoSite Radiation Therapy System (RTS), a new device for delivering brachytherapy following breast-conserving surgery. In Europe, some groups started a prospective multicentre trial to investigate the use of the MammoSite RTS. In this early publication, we analysed the surgical procedure and placement of the MammoSite, treatment planning and radiation delivery complications, and early cosmesis, as well as the comfort of the patients. Between June 2002 and March 2005, a total of 54 low-risk breast cancer patients fulfilling the enrolment criteria were implanted intra- or postoperatively using the MammoSite applicator. After inflating the balloon in the excision cavity, the reference isodose was defined 1cm from the balloon's surface. Twenty-eight patients were treated with primary brachytherapy with a total dose of 34 Gy (2x3.4 Gy) and 16 patients had a boost with a mean dose of 13.3 Gy (range: 7.5-15 Gy; 2x2.5 Gy) combined with external beam radiotherapy (EBRT). Doses ranged between 46 and 50 Gy. We analysed the postimplant anatomic position of the applicator in relation to the skin and chest wall as well as the geometric form of the balloon via ultrasound, computed tomography and X-ray before, during and after the treatment. Forty-four out of 54 patients (81.5%) were eligible for MammoSite RTS brachytherapy. Ten patients were excluded from the trial due to the strict study criteria and received no brachytherapy. Balloon rupture occurred in two cases. We observed seroma in 16 patients (36%); furthermore, an abscess developed in two patients (4.5%) within 3 months of implantation. Postoperative air gaps and haematoma were successfully reduced by draining the operation cavity in one institution. At a mean follow-up of 14 months (range 3-31 months), the skin-related side effects observed were skin discoloration or inflammation in 36 patients (82%) and teleangiectasia in eight patients (18%). The MammoSite RTS is a feasible treatment modality for postoperative partial breast irradiation after breast-conserving surgery for selected low-risk breast cancer patients. The main advantage of the system is the necessity of only one applicator for the delivery of fractionated radiotherapy over a 5-day treatment period. In addition, patient tolerance of the procedure is high. Based on this early experience, the method may serve as a successful alternative to conventional multicatheter brachytherapy for a highly select group of patients, but we have to bear in mind the higher level of acute toxicity.
Neurological Effects of Bisphenol A and its Analogues
Inadera, Hidekuni
2015-01-01
The endocrine disrupting chemical bisphenol A (BPA) is widely used in the production of polycarbonate plastics and epoxy resins. The use of BPA-containing products in daily life makes exposure ubiquitous, and the potential human health risks of this chemical are a major public health concern. Although numerous in vitro and in vivo studies have been published on the effects of BPA on biological systems, there is controversy as to whether ordinary levels of exposure can have adverse effects in humans. However, the increasing incidence of developmental disorders is of concern, and accumulating evidence indicates that BPA has detrimental effects on neurological development. Other bisphenol analogues, used as substitutes for BPA, are also suspected of having a broad range of biological actions. The objective of this review is to summarize our current understanding of the neurobiological effects of BPA and its analogues, and to discuss preventive strategies from a public health perspective. PMID:26664253
Ikhlas, Shoeb; Usman, Afia; Ahmad, Masood
2018-04-24
Interaction studies of bisphenol analogues; biphenol-A (BPA), bisphenol-B (BPB), and bisphenol-F (BPF) with bovine serum albumin (BSA) were performed using multi-spectroscopic and molecular docking studies at the protein level. The mechanism of binding of bisphenols with BSA was dynamic in nature. SDS refolding experiments demonstrated no stabilization of BSA structure denatured by BPB, however, BSA denatured by BPA and BPF was found to get stabilized. Also, CD spectra and molecular docking studies revealed that BPB bound more strongly and induced more conformational changes in BSA in comparison to BPA. Hence, this study throws light on the replacement of BPA by its analogues and whether the replacement is associated with a possible risk, raising a doubt that perhaps BPB is not a good substitute of BPA.
16 CFR 1117.4 - Time for filing a report.
Code of Federal Regulations, 2010 CFR
2010-01-01
... REPORTING OF CHOKING INCIDENTS INVOLVING MARBLES, SMALL BALLS, LATEX BALLOONS AND OTHER SMALL PARTS § 1117.4... marble, small ball, or latex balloon or on a marble, small ball, latex balloon, or other small part...
Ignition of Hydrogen Balloons by Model-Rocket-Engine Igniters.
ERIC Educational Resources Information Center
Hartman, Nicholas T.
2003-01-01
Describes an alternative method for exploding hydrogen balloons as a classroom demonstration. Uses the method of igniting the balloons via an electronic match. Includes necessary materials to conduct the demonstration and discusses potential hazards. (SOE)
Sunada, Keijiro; Yamamoto, Hironori; Kita, Hiroto; Yano, Tomonori; Sato, Hiroyuki; Hayashi, Yoshikazu; Miyata, Tomohiko; Sekine, Yutaka; Kuno, Akiko; Iwamoto, Michiko; Ohnishi, Hirohide; Ido, Kenichi; Sugano, Kentaro
2005-01-01
AIM: To evaluate the clinical outcome of enteroscopy, using the double-balloon method, focusing on the involvement of neoplasms in strictures of the small intestine. METHODS: Enteroscopy, using the double-balloon method, was performed between December 1999 and December 2002 at Jichi Medical School Hospital, Japan and strictures of the small intestine were found in 17 out of 62 patients. These 17 consecutive patients were subjected to analysis. RESULTS: The double-balloon enteroscopy contributed to the diagnosis of small intestinal neoplasms found in 3 out of 17 patients by direct observation of the strictures as well as biopsy sampling. Surgical procedures were chosen for these three patients, while balloon dilation was chosen for the strictures in four patients diagnosed with inflammation without involvement of neoplasm. CONCLUSION: Double-balloon enteroscopy is a useful method for the diagnosis and treatment of strictures in the small bowel. PMID:15742422
NASA Astrophysics Data System (ADS)
Gaskin, J. A.; Smith, I. S.; Jones, W. V.
In 1783, the Montgolfier brothers ushered in a new era of transportation and exploration when they used hot air to drive an un-tethered balloon to an altitude of 2 km. Made of sackcloth and held together with cords, this balloon challenged the way we thought about human travel, and it has since evolved into a robust platform for performing novel science and testing new technologies. Today, high-altitude balloons regularly reach altitudes of 40 km, and they can support payloads that weigh more than 3000 kg. Long-duration balloons can currently support mission durations lasting 55 days, and developing balloon technologies (i.e. Super-Pressure Balloons) are expected to extend that duration to 100 days or longer; competing with satellite payloads. This relatively inexpensive platform supports a broad range of science payloads, spanning multiple disciplines (astrophysics, heliophysics, planetary and earth science). Applications extending beyond traditional science include testing new technologies for eventual space-based application and stratospheric airships for planetary applications.
Balloon Ascent: 3-D Simulation Tool for the Ascent and Float of High-Altitude Balloons
NASA Technical Reports Server (NTRS)
Farley, Rodger E.
2005-01-01
The BalloonAscent balloon flight simulation code represents a from-scratch development using Visual Basic 5 as the software platform. The simulation code is a transient analysis of balloon flight, predicting the skin and gas temperatures along with the 3-D position and velocity in a time and spatially varying environment. There are manual and automated controls for gas valving and the dropping of ballast. Also, there are many handy calculators, such as appropriate free lift, and steady-state thermal solutions with temperature gradients. The strength of this simulation model over others in the past is that the infrared environment is deterministic rather than guessed at. The ground temperature is specified along with the emissivity, which creates a ground level IR environment that is then partially absorbed as it travels upward through the atmosphere to the altitude of the balloon.
[Effect of hot-air balloon crossings on animals in the open air].
Stephan, E
1997-02-01
Since the middle of the eighties owners of animals increasingly claimed compensation from balloon pilots. They asserted, that their animals got restless due to strange optical and acoustical stimuli caused by low altitude crossing of hot-air balloons and were damaged while trying to get out of the way or to escape. Very low altitude "Contour crossing" of hot-air balloons, mainly forming the basis of complaints, is only left possible in a limited degree in Germany since the air traffic regulations were changed to a higher minimum safety altitude (Air Traffic Act, LuftVO, version of March 21, 1995) and the violating balloon pilot may be disciplined. The paper is dealing with the principle of hot-air ballooning, with the feasibility of the pilot to avoid and restrict damages, with the possibilities to assign damages to a potential cause and with the legal basis.
NASA Astrophysics Data System (ADS)
Bowman, D. C.; Albert, S.; Dexheimer, D.; Murphy, S.; Mullen, M.
2017-12-01
Existing scientific ballooning solutions for multi hour flights in the upper troposphere/lower stratosphere are expensive and/or technically challenging. In contrast, solar hot air balloons are inexpensive and simple to construct. These balloons, which rely solely on sunlight striking a darkened envelope, can deliver payloads to 22 km altitude and maintain level flight until sunset. We describe an experimental campaign in which five solar hot air balloons launched in 45 minutes created a free flying infrasound (low frequency sound) microphone network that remained in the air for over 12 hours. We discuss the balloons' trajectory, maximum altitude, and stability as well as present results from the infrasound observations. We assess the performance and limitations of this design for lightweight atmospheric instrumentation deployments that require multi-hour flight times. Finally, we address the possibilities of multi day flights during the polar summer and on other planets.
Wind Tunnel Investigation of a Balloon as Decelerator at Mach Numbers from 1.47 to 2.50
NASA Technical Reports Server (NTRS)
McShera, John T.; Keyes, J. Wayne
1961-01-01
A wind-tunnel investigation was conducted to study the characteristics of a towed spherical balloon as a drag device at Mach numbers from 1.47 to 2.50, Reynolds numbers from 0.36 x 10(exp 6) to 1.0 x 10(exp 6) , and angles of attack from -15 to 15 degrees. Tow-cable length was approximately 24 inches from asymmetric body to cone on the upstream side of the balloon. As the tow cable was lengthened the balloon reached a point in the test section where wall-reflected shocks intersected the balloon and caused severe oscillations. As a result, the tow cable broke and the inflatable balloon model was destroyed. Further tests used a model rigid plastic sphere 6.75 inches in diameter. Tow cable length was approximately 24 inches from asymmetric body to the upstream side of the sphere.
Detection of Artificially Generated Seismic Signals Using Balloon-Borne Infrasound Sensors
Krishnamoorthy, Siddharth; Komjathy, Attila; Pauken, Michael T.; ...
2018-04-24
Here, we conducted an experiment in Pahrump, Nevada, in June 2017, where artificial seismic signals were created using a seismic hammer, and the possibility of detecting them from their acoustic signature was examined. In this work, we analyze the pressure signals recorded by highly sensitive barometers deployed on the ground and on tethers suspended from balloons. Our signal processing results show that wind noise experienced by a barometer on a free-flying balloon is lower compared to one on a moored balloon. This has never been experimentally demonstrated in the lower troposphere. While seismoacoustic signals were not recorded on the hotmore » air balloon platform owing to operational challenges, we demonstrate the detection of seismoacoustic signals on our moored balloon platform. Our results have important implications for performing seismology in harsh surface environments such as Venus through atmospheric remote sensing.« less
Initial experience with the Europass: a new ultra-low profile monorail balloon catheter.
Zimarino, M; Corcos, T; Favereau, X; Tamburino, C; Toussaint, M; Spaulding, C; Guérin, Y
1994-09-01
One of the causes for percutaneous transluminal coronary angioplasty (PTCA) failure is the inability to cross the lesion with the balloon catheter after guidewire positioning. The Europass coronary angioplasty catheter is a monorail Duralyn balloon catheter developed to enhance lesion crossability and to overcome this limitation. This system was evaluated in 50 patients in which target lesions were chronic total coronary occlusions (12 cases) or stenoses that could not be reached or crossed by other new monorail balloon catheters. Overall procedural success was obtained in 49/50 patients (98%), using a single Europass balloon catheter in 46/50 patients (92%), with no in-hospital complications. Its low profile, small distal shaft, and excellent trackability allowed successful angioplasty in cases where other catheters failed. This balloon catheter represents a significant advance in angioplasty technology and can be considered as a first-choice device for a safe and expeditious single-operator procedure.
A balloon-borne prototype for demonstrating the concept of JEM-EUSO
NASA Astrophysics Data System (ADS)
von Ballmoos, P.; Santangelo, A.; Adams, J. H.; Barrillon, P.; Bayer, J.; Bertaina, M.; Cafagna, F.; Casolino, M.; Dagoret, S.; Danto, P.; Distratis, G.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Evrard, J.; Gorodetzky, Ph.; Haungs, A.; Jung, A.; Kawasaki, Y.; Medina-Tanco, G.; Mot, B.; Osteria, G.; Parizot, E.; Park, I. H.; Picozza, P.; Prévôt, G.; Prieto, H.; Ricci, M.; Rodríguez Frías, M. D.; Roudil, G.; Scotti, V.; Szabelski, J.; Takizawa, Y.; Tusno, K.
2014-05-01
EUSO-BALLOON has been conceived as a pathfinder for JEM-EUSO, a mission concept for a space-borne wide-field telescope monitoring the Earth's nighttime atmosphere with the objective of recording the ultraviolet light from tracks initiated by ultra-high energy cosmic rays. Through a series of stratospheric balloon flights performed by the French Space Agency CNES, EUSO-BALLOON will serve as a test-bench for the key technologies of JEM-EUSO. EUSO-BALLOON shall perform an end-to-end test of all subsystems and components, and prove the global detection chain while improving our knowledge of the atmospheric and terrestrial ultraviolet background. The balloon-instrument also has the potential to detect for the first time UV-light generated by atmospheric air-shower from above, marking a milestone in the development of UHECR science, and paving the way for any future large scale, space-based ultra-high energy cosmic ray observatory.
Detection of Artificially Generated Seismic Signals Using Balloon-Borne Infrasound Sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krishnamoorthy, Siddharth; Komjathy, Attila; Pauken, Michael T.
Here, we conducted an experiment in Pahrump, Nevada, in June 2017, where artificial seismic signals were created using a seismic hammer, and the possibility of detecting them from their acoustic signature was examined. In this work, we analyze the pressure signals recorded by highly sensitive barometers deployed on the ground and on tethers suspended from balloons. Our signal processing results show that wind noise experienced by a barometer on a free-flying balloon is lower compared to one on a moored balloon. This has never been experimentally demonstrated in the lower troposphere. While seismoacoustic signals were not recorded on the hotmore » air balloon platform owing to operational challenges, we demonstrate the detection of seismoacoustic signals on our moored balloon platform. Our results have important implications for performing seismology in harsh surface environments such as Venus through atmospheric remote sensing.« less
The Latest Developments in NASA's Long Duration Balloon Systems
NASA Astrophysics Data System (ADS)
Stilwell, Bryan D.
The Latest Developments in NASA’s Long Duration Balloon Systems Bryan D. Stilwell, bryan.stilwell@csbf.nasa.gov Columbia Scientific Balloon Facility, Palestine, Texas, USA The Columbia Scientific Balloon Facility, located in Palestine, Texas offers the scientific community a high altitude balloon based communications platform. Scientific payload mass can exceed 2722 kg with balloon float altitudes on average of 40000 km and flight duration of up to 100 days. Many developments in electrical systems have occurred over the more than 25 years of long duration flights. This paper will discuss the latest developments in electronic systems related to long duration flights. Over the years, the long duration flights have increased in durations exceeding 56 days. In order to support these longer flights, the systems have had to increase in complexity and reliability. Several different systems that have been upgraded and/or enhanced will be discussed.
Anderson, Jordan A; Lamichhane, Sujan; Remund, Tyler; Kelly, Patrick; Mani, Gopinath
2016-01-01
Drug-coated balloons (DCBs) are used to treat various cardiovascular diseases. Currently available DCBs carry drug on the balloon surface either solely or using different carriers. Several studies have shown that a significant amount of drug is lost in the blood stream during balloon tracking to deliver only a sub-therapeutic level of drug at the treatment site. This research is focused on developing paclitaxel (PAT) loaded polyethylene oxide (PEO) films (PAT-PEO) as a controlled drug delivery carrier for DCBs. An array of PAT-PEO films were developed in this study to provide tailored release of >90% of drug only at specific time intervals, which is the time frame required for carrying out balloon-based therapy. The characterizations of PAT-PEO films using SEM, FTIR, and DSC showed that the films developed were homogenous and the PAT was molecularly dispersed in the PEO matrix. Mechanical tests showed that most PAT-PEO films developed were flexible and ductile, with yield and tensile strengths not affected after PAT incorporation. The viability, proliferation, morphology, and phenotype of smooth muscle cells (SMCs) interacted with control-PEO and PAT-PEO films were investigated. All control-PEO and PAT-PEO films showed a significant inhibitory effect on the growth of SMCs, with the degree of inhibition strongly dependent on the w/v% of the polymer used. The PAT-PEO coating was produced on the balloons. The integrity of PAT-PEO coating was well maintained without any mechanical defects occurring during balloon inflation or deflation. The drug release studies showed that only 15% of the total PAT loaded was released from the balloons within the initial 1min (typical balloon tracking time), whereas 80% of the PAT was released between 1min and 4min (typical balloon treatment time). Thus, this study demonstrated the use of PEO as an alternate drug delivery system for the balloons. Atherosclerosis is primarily responsible for cardiovascular diseases (CVDs) in millions of patients every year. Drug-coated balloons (DCBs) are commonly used to treat various CVDs. However, in several currently used DCBs, a significant amount of drug is lost in the blood stream during balloon tracking to deliver only a sub-therapeutic level of drug at the treatment site. In this study, paclitaxel containing polyethylene oxide (PEO) films were developed to provide unique advantages including drug release profiles specifically tailored for balloon-based therapy, homogeneous films with molecularly dispersed drug, flexible and ductile films, and exhibits significant inhibitory effect on smooth muscle cell growth. Thus, this study demonstrated the use of PEO as an alternate drug delivery platform for DCBs to improve its efficacy. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Risk-Taking and the Feedback Negativity Response to Loss among At-Risk Adolescents
Crowley, Michael J.; Wu, Jia; Crutcher, Clifford; Bailey, Christopher A.; Lejuez, C.W.; Mayes, Linda C.
2009-01-01
Event-related brain potentials were examined in 32 adolescents (50% female) from a high-risk sample, who were exposed to cocaine and other drugs prenatally. Adolescents were selected for extreme high- or low-risk behavior on the Balloon Analog Risk Task, a measure of real-world risk-taking propensity. The feedback error-related negativity (fERN), an event-related potential (ERP) that occurs when an expected reward does not occur, was examined in a game in which choices lead to monetary gains and losses with feedback delayed 1 or 2 s. The fERN was clearly visible in the fronto-central scalp region in this adolescent sample. Feedback type, feedback delay, risk status, and sex were all associated with fERN variability. Monetary feedback also elicited a P300-like component, moderated by delay and sex. Delaying reward feedback may provide a means for studying complementary functioning of dopamine and norepinephrine systems. PMID:19372694
NASA Scientific Balloon Team Hopes to Break Flight Duration Record with New Zealand Launch
2017-12-08
After years of tests and development, NASA’s Balloon Program team is on the cusp of expanding the envelope in high-altitude, heavy-lift ballooning with its super pressure balloon (SPB) technology. NASA’s scientific balloon experts are in Wanaka, New Zealand, prepping for the fourth flight of an 18.8 million-cubic-foot (532,000 cubic-meter) balloon, with the ambitious goal of achieving an ultra-long-duration flight of up to 100 days at mid-latitudes. Launch of the pumpkin-shaped, football stadium-size balloon is scheduled for sometime after April 1, 2016, from Wanaka Airport, pending final checkouts and flight readiness of the balloon and supporting systems. Once launched, the SPB, which is made from 22-acres of polyethylene film – similar to a sandwich bag, but stronger and more durable – will ascend to a nearly constant float altitude of 110,000 feet (33.5 km). The balloon will travel eastward carrying a 2,260-pound (1,025 kg) payload consisting of tracking, communications and scientific instruments. NASA expects the SPB to circumnavigate the globe once every one to three weeks, depending on wind speeds in the stratosphere. Read more: go.nasa.gov/1p56xKR NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Cho, Moonsung; Neubauer, Peter; Fahrenson, Christoph; Rechenberg, Ingo
2018-06-01
The physical mechanism of aerial dispersal of spiders, "ballooning behavior," is still unclear because of the lack of serious scientific observations and experiments. Therefore, as a first step in clarifying the phenomenon, we studied the ballooning behavior of relatively large spiders (heavier than 5 mg) in nature. Additional wind tunnel tests to identify ballooning silks were implemented in the laboratory. From our observation, it seems obvious that spiders actively evaluate the condition of the wind with their front leg (leg I) and wait for the preferable wind condition for their ballooning takeoff. In the wind tunnel tests, as-yet-unknown physical properties of ballooning fibers (length, thickness, and number of fibers) were identified. Large spiders, 16-20 mg Xysticus spp., spun 50-60 nanoscale fibers, with a diameter of 121-323 nm. The length of these threads was 3.22 ± 1.31 m (N = 22). These physical properties of ballooning fibers can explain the ballooning of large spiders with relatively light updrafts, 0.1-0.5 m s-1, which exist in a light breeze of 1.5-3.3 m s-1. Additionally, in line with previous research on turbulence in atmospheric boundary layers and from our wind measurements, it is hypothesized that spiders use the ascending air current for their aerial dispersal, the "ejection" regime, which is induced by hairpin vortices in the atmospheric boundary layer turbulence. This regime is highly correlated with lower wind speeds. This coincides well with the fact that spiders usually balloon when the wind speed is lower than 3 m s-1.
Saurer, Eric M.; Yamanouchi, Dai; Liu, Bo; Lynn, David M.
2010-01-01
We report an approach for the localized delivery of plasmid DNA to vascular tissue from the surfaces of inflatable embolectomy catheter balloons. Using a layer-by-layer approach, ultrathin multilayered polyelectrolyte films were fabricated on embolectomy catheter balloons by alternately adsorbing layers of a hydrolytically degradable poly(β-amino ester) and plasmid DNA. Fluorescence microscopy revealed that the films coated the surfaces of the balloons uniformly. Coated balloons that were incubated in phosphate-buffered saline at 37 °C released ~25 μg DNA/cm2 over 24 hours. Analysis of the DNA by gel electrophoresis showed that the DNA was released in open-circular (‘nicked’) and supercoiled conformations, and in vitro cell transfection assays confirmed that the released DNA was transcriptionally active. Arterial injury was induced in the internal carotid arteries of Sprague-Dawley rats using uncoated balloons, followed by treatment with film-coated balloons for 20 minutes. X-gal, immunohistochemical, and immunofluorescence staining of sectioned arteries indicated high levels of β-galactosidase or enhanced green fluorescent protein (EGFP) expression in arteries treated with film-coated balloons. β-galactosidase and EGFP expression were observed throughout the medial layers of arterial tissue, and around approximately two-thirds of the circumference of the treated arteries. The layer-by-layer approach reported here provides a general platform for the balloon-mediated delivery of DNA to vascular tissue. Our results suggest the potential of this approach to deliver therapeutically relevant DNA to prevent complications such as intimal hyperplasia that arise after vascular interventions. PMID:20933275
Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons
NASA Technical Reports Server (NTRS)
Smith, David J.; Sowa, Marianne
2017-01-01
Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.
High submuscular placement of urologic prosthetic balloons and reservoirs via transscrotal approach.
Morey, Allen F; Cefalu, Christopher A; Hudak, Steven J
2013-02-01
Traditional placement of inflatable penile prosthesis (IPP) reservoirs and/or artificial urinary sphincter (AUS) balloons into the space of Retzius may be challenging following major pelvic surgery. The aim of this study is to report our 1-year experience using a novel technique for high balloon/reservoir placement beneath the rectus abdominus muscle, thus completely obviating deep pelvic dissection during prosthetic urologic surgery. A retrospective review of all patients who underwent IPP and/or AUS placement between June 2011 and June 2012 was performed. All had AUS balloons and/or IPP reservoirs placed in a submuscular location by bluntly tunneling through the external inguinal ring into a potential space between the transversalis fascia and the rectus abdominus muscle using a long, angled, lung grasping clamp. Patient demographics, perioperative outcomes, and initial follow-up patient-reported outcomes were reviewed. During the study period, 120 submuscular balloons/reservoirs were inserted in 107 consecutive patients who underwent placement of an IPP (61 patients), AUS (33 patients), or both (13 patients). Among our 48 most recent patients, 41 (85%) reported they were totally unable to feel their balloon/reservoir, and all but two patients reported no bother from the submuscular balloon/reservoir placement. Of the 120 total submuscular balloons and reservoirs, surgical time and outcomes of the prosthetic procedures appeared similar to those placed using traditional methods; two reservoirs required revision surgery for repositioning. High submuscular placement of genitourinary prosthetic balloons and reservoirs via a transscrotal approach is both safely and effective, while avoiding deep retropubic dissection. © 2012 International Society for Sexual Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Min Tae; Park, Jung-Hoon; Shin, Ji Hoon, E-mail: jhshin@amc.seoul.kr
PurposeTo determine the effect of contrast medium dilution during tracheal balloon dilation on balloon deflation time and visibility using a 3-dimensional (3D) printed airway phantom.Materials and MethodsA comparison study to investigate balloon deflation times and image quality was performed using two contrast agents with different viscosities, i.e., iohexol and ioxithalamate, and six contrast dilutions with a 3D printed airway phantom.ResultsCompared to 1:0 concentration, 3:1, 2:1, 1:1, 1:2, and 1:3, contrast/saline ratios resulted in a 46% (56.2 s), 59.8% (73.1 s), 74.9% (91.6 s), 81.7% (99.8 s), and 83.5% (102 s) reduction for iohexol, respectively, and a 51.8% (54.7 s), 63.8% (67.6 s), 74.7% (79.2 s), 80.5% (85.3 s), andmore » 82.4% (87.4 s) reduction for ioxithalamate, respectively, in the mean balloon deflation time, although at the expense of decreased balloon opacity (3.5, 6.9, 11.1, 12.4, and 13.9%, for iohexol, respectively, and 3.2, 6, 9.6, 10.8, and 12.4%, for ioxithalamate, respectively).ConclusionsUse of a lower viscosity contrast agent and higher contrast dilution is considered to be able to reduce balloon deflation times and then simultaneously decrease visualization of balloons. The rapid balloon deflation time is likely to improve the safe performance of interventional procedures.« less