Umakanthan, Ramanan; Hoff, Steven J; Solenkova, Natalia; Wigger, Mark A; Keebler, Mary E; Lenneman, Andrew; Leacche, Marzia; Disalvo, Thomas G; Ooi, Henry; Naftilan, Allen J; Byrne, John G; Ahmad, Rashid M
2012-05-01
Axillary intra-aortic balloon pump therapy has been described as a bridge to transplant. Advantages over femoral intra-aortic balloon pump therapy include reduced incidence of infection and enhanced patient mobility. We identified the patients who would benefit most from this therapy while awaiting heart transplantation. We conducted a single-center, retrospective observational study to evaluate outcomes from axillary intra-aortic balloon pump therapy. These included hemodynamic parameters, duration of support, and success in bridging to transplant. We selected patients on the basis of history of sternotomy, elevated panel-reactive antibody, and small body habitus. Patients were made to ambulate aggressively beginning on postoperative day 1. Between September 2007 and September 2010, 18 patients underwent axillary intra-aortic balloon pump therapy. All patients had the devices placed through the left axillary artery with a Hemashield side graft (Boston Scientific, Natick, Mass). Before axillary placement, patients underwent femoral placement to demonstrate hemodynamic benefit. Duration of support ranged from 5 to 63 days (median = 19 days). There was marked improvement in ambulatory potential and hemodynamic parameters, with minimal blood transfusion requirements. There were no device-related infections. Some 72% of the patients (13/18) were successfully bridged to transplantation. Axillary intra-aortic balloon pump therapy provides excellent support for selected patients as a bridge to transplant. The majority of the patients were successfully bridged to transplant and discharged. Although this therapy has been described in previous studies, this is the largest series to incorporate a regimen of aggressive ambulation with daily measurements of distances walked. Copyright © 2012. Published by Mosby, Inc.
Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop
2015-01-01
Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.
The role of the Intra‐aortic balloon pump in supporting children with acute cardiac failure
Collison, Sathiakar Paul; Dagar, Kulbhusan Singh
2007-01-01
Acute heart failure occurs in children following the operative correction of a congenital anomaly, as an acute change in a child with a congenital anomaly, or in a structurally normal heart with acute myocarditis. Acute heart failure in children justifies aggressive treatment because of the high potential for complete recovery. The options for providing mechanical support to the failing heart in a child include extracorporeal membrane oxygenation, left ventricular assist devices and the use of the intra‐aortic balloon pump (IABP). The principles of intra‐aortic balloon pump usage are described, and the literature regarding the indications and outcome of its use in children is reviewed. PMID:17488858
Off-pump surgery: a choice in unstable angina.
Kohli, Vijay; Goel, Mukesh; Sharma, Vijay Kumar; Mishra, Yugal; Malhotra, Rajneesh; Mehta, Yatin; Trehan, Naresh
2003-12-01
The benefit and safety of off-pump coronary artery bypass surgery in patients with unstable angina was assessed retrospectively. From February 1996 to October 2001, 5,306 patients underwent multivessel off-pump coronary artery bypass, of whom 920 (17%) had unstable angina. In these 920 patients, ejection fractions ranged from 15% to 70%, 203 (22%) had an ejection fraction of 20%-35%, and 11 (1%) had an ejection fraction < 20%. Triple-vessel disease was present in 625 patients. Preoperative intraaortic balloon pump support was used in 28 patients. Operative approaches included mid sternotomy (86%), lower partial sternotomy (9%), and left anterior thoracotomy (2%). The number of grafts ranged from 1 to 5 with a mean of 2.43 +/- 0.86, and 92.3% of patients received a left internal mammary artery graft. Twenty-two patients need intraoperative intraaortic balloon pumping. Ten patients (1%) suffered perioperative myocardial infarction. The mean hospital stay was 7.8 +/- 4.3 days. Hospital mortality was 2/920 (0.22%). Intraaortic balloon pumping was helpful in these cases of unstable angina refractory to medical therapy. Off-pump coronary artery surgery was found to be safe and beneficial in these patients.
Left Ventricular Free Wall Rupture in Acute Myocardial Infarction
Amir, Offer; Smith, Ronald; Nishikawa, Akaira; Gregoric, Igor D.; Smart, Frank W.
2005-01-01
We describe a case of subacute left ventricular free wall rupture during acute myocardial infarction in a 68-year-old man. The diagnosis was confirmed by echocardiography. The patient was supported by an intra-aortic balloon pump until the ruptured wall could be successfully repaired by suturing and gluing a pericardial patch over the defect and bypassing the left anterior descending coronary artery with a vein graft. This case demonstrates that left ventricular free wall rupture is not always fatal and that early diagnosis and institution of intra-aortic balloon pump support in such patients can allow successful bridging to definitive emergency surgical therapy. PMID:16392235
On the feasibility of closed-loop control of intra-aortic balloon pumping
NASA Technical Reports Server (NTRS)
Clark, J. W., Jr.; Bourland, H. M.; Kane, G. R.
1973-01-01
A closed-loop control scheme for the control of intra-aortic balloon pumping has been developed and tested in dog experiments. A performance index reflecting the general objectives of balloon-assist pumping is developed and a modified steepest ascent control algorithm is utilized for the selection of a proper operating point for the balloon during its pumping cycle. This paper attempts to indicate the feasibility of closed-loop control of balloon pumping, and particularly its flexibility in achieving both diastolic augmentation of mean aortic pressure and control of the level of end-diastolic pressure (EDP) an important factor in reducing heart work.
Ioseliani, G D; Chilaia, S M
1983-02-01
A basically new design for the reversing balloon pump has been proposed for increasing the efficacy of intra-aortic balloon pumping (IABP). The device not only causes a significant increase in discharge, but also permits control of the central and peripheral circulation within the desired limits owing to back-and-forth movements (like a piston) of the balloon pump. Standard one- and two-chamber balloon pumps were compared. In addition to traditional hemodynamic and biochemical indexes, the efficacy of IABP was assessed based on electrode monitor control of PO2 and pH in the myocardium, peripheral tissues, and circulating blood. Based on 54 experiments on dogs, it was found that IABP with reversing balloon pumps in synchronous pulsation resulted in survival of 69% of the cases; PO2 and pH levels in the myocardium, tissues, and blood in the coronary sinus were close to normal, and coronary blood flow and peripheral circulation were increased. With standard one-chamber balloon pumps, the survival rate did not exceed 33.4%; PO2 and pH in the peripheral tissues reached critical levels.
Privratsky, Jamie R; Diaz, Sebastian; Nicoara, Alina; Daneshmand, Mani A
2018-05-01
Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is an increasingly utilized life-saving measure. However, left-ventricular distention from inadequate left-ventricular off-loading can lead to unwanted pulmonary and cardiac complications. We are writing to indicate our agreement with a recent article by Brechot et al. published in the June 2017 issue where the authors demonstrated that intra-aortic balloon pump provides mechanical support to off-load the left ventricle during VA-ECMO, which prevents pulmonary edema.
Hunt, Adam; Waldin, Owen; Slim, Hani; Brar, Ranjeet
2016-06-06
This is a unique case report describing complex limb salvage in a patient who experienced acute limb ischaemia due to a complication of intra-aortic balloon pump (IABP) counterpulsation. This case focuses on a patient who had an IABP counterpulsation device inserted following myocardial infarction, requiring urgent coronary artery bypass grafting for acute coronary syndrome. Postoperatively, the IABP could not be removed, with consequent iliac thrombosis and acute limb ischaemia. Emergency femoral-to-femoral crossover bypass was performed using a polytetrafluoroethylene graft. A portion of the IABP balloon tip was entrapped and retained, however, and became the focus of delayed septicaemia, resulting in graft infection and wound breakdown 6 weeks later. Explantation of the residual balloon tip, ligation of the right external iliac artery and redo femoral-femoral crossover using the great saphenous vein were successfully performed. 2016 BMJ Publishing Group Ltd.
Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms
Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc
2014-01-01
Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping designs have been developed to study the pump performance and capacity at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data shows that, the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon. PMID:24441792
Nursing care of the ambulatory patient with a mechanical assist device.
Reedy, J E; Ruzevich, S A; Noedel, N R; Vitale, L J; Merkle, E J
1990-01-01
Since 1986, 10 men and one woman were ambulatory while supported with mechanical assist devices as a bridge to heart transplantation. Four patients received a subclavian intraaortic balloon pump, two were supported with a Novacor left ventricular assist system, three patients received Pierce-Donachy ventricular assist devices, and one patient received a Jarvik 7 total artificial heart. One patient with an intraaortic balloon pump later received a left ventricular assist system because of hemodynamic deterioration despite the intraaortic balloon pump. Before device insertion all 11 patients were in cardiogenic shock despite inotropic and vasodilator support. The time of support ranged from 8 to 440 days (median, 24 days). In-house coverage by the circulatory support team was necessary only during the first 24 to 72 hours of support. When the patient's condition was stabilized, nursing staff monitored the devices with "on-call" availability of the circulatory support team. After implant of the device, all patients were able to perform activities of daily living. Once patients were able to walk in their hospital rooms, ambulation began in the hallways; frequency and distance were gradually increased. Four of the patients walked outside the hospital while tethered to the drive console. Daily physical therapy contributed to increased exercise tolerance. Protective isolation was used before and after transplantation to minimize the risk of infection. Sterile dressing changes (gown, gloves, mask) were applied to drive lines, cannula sites, and incisions. All invasive lines and catheters were removed as soon as the patient's clinical condition warranted, and noninvasive monitoring was used to decrease the chance of infection.(ABSTRACT TRUNCATED AT 250 WORDS)
Rocha Ferreira, Graziela Santos; de Almeida, Juliano Pinheiro; Landoni, Giovanni; Vincent, Jean Louis; Fominskiy, Evgeny; Gomes Galas, Filomena Regina Barbosa; Gaiotto, Fabio A; Dallan, Luís Oliveira; Franco, Rafael Alves; Lisboa, Luiz Augusto; Palma Dallan, Luis Roberto; Fukushima, Julia Tizue; Rizk, Stephanie Itala; Park, Clarice Lee; Strabelli, Tânia Mara; Gelas Lage, Silvia Helena; Camara, Ligia; Zeferino, Suely; Jardim, Jaquelline; Calvo Arita, Elisandra Cristina Trevisan; Caldas Ribeiro, Juliana; Ayub-Ferreira, Silvia Moreira; Costa Auler, Jose Otavio; Filho, Roberto Kalil; Jatene, Fabio Biscegli; Hajjar, Ludhmila Abrahao
2018-04-30
The aim of this study was to evaluate the efficacy of perioperative intra-aortic balloon pump use in high-risk cardiac surgery patients. A single-center randomized controlled trial and a meta-analysis of randomized controlled trials. Heart Institute of São Paulo University. High-risk patients undergoing elective coronary artery bypass surgery. Patients were randomized to receive preskin incision intra-aortic balloon pump insertion after anesthesia induction versus no intra-aortic balloon pump use. The primary outcome was a composite endpoint of 30-day mortality and major morbidity (cardiogenic shock, stroke, acute renal failure, mediastinitis, prolonged mechanical ventilation, and a need for reoperation). A total of 181 patients (mean [SD] age 65.4 [9.4] yr; 32% female) were randomized. The primary outcome was observed in 43 patients (47.8%) in the intra-aortic balloon pump group and 42 patients (46.2%) in the control group (p = 0.46). The median duration of inotrope use (51 hr [interquartile range, 32-94 hr] vs 39 hr [interquartile range, 25-66 hr]; p = 0.007) and the ICU length of stay (5 d [interquartile range, 3-8 d] vs 4 d [interquartile range, 3-6 d]; p = 0.035) were longer in the intra-aortic balloon pump group than in the control group. A meta-analysis of 11 randomized controlled trials confirmed a lack of survival improvement in high-risk cardiac surgery patients with perioperative intra-aortic balloon pump use. In high-risk patients undergoing cardiac surgery, the perioperative use of an intra-aortic balloon pump did not reduce the occurrence of a composite outcome of 30-day mortality and major complications compared with usual care alone.
Vascular complications following intra-aortic balloon pump implantation: an updated review
de Jong, Monique M; Lorusso, Roberto; Al Awami, Fatima; Matteuci, Francesco; Parise, Orlando; Lozekoot, Pieter; Bonacchi, Massimo; Maessen, Jos G; Johnson, Daniel M; Gelsomino, Sandro
2017-01-01
Background: The use of the intra-aortic balloon pump (IABP) as a support device remains controversial due to the fact that a number of studies have shown no benefit in end mortality whilst using this device. One of the reasons for this could be the increase in vascular complications when using the pump. Therefore, the aim of the present review was to assess the current literature available with regards to IABP vascular complications during the clinical situation. Methods: A literature search was performed, searching for IABP complications in adult human studies between 1990 and 2016. Results: A total of 20 reports were identified as fitting the criteria of this study. The majority of vascular complications were limb ischemia, bleeding or mesenteric ischemia. The overall incidence of vascular complications ranged from 0.94% to 31.1%. Diabetes, peripheral vascular disease and hypertension, as well as smoking were all identified as risk factors for complications following IABP. Furthermore, studies supported the use of sheathless balloon insertion to reduce the risk of complications. Conclusion: Major vascular complications, including limb and mesenteric ischemia as well as bleeding and hemorrhage, have been associated with IABP. However, the incidence of these complications was generally low. Further studies are still required to truly understand the risk/benefit associated with the use of IABP. PMID:28816093
Caruso, Maria Vittoria; Gramigna, Vera; Renzulli, Attilio; Fragomeni, Gionata
2016-01-01
The extracorporeal membrane oxygenation (ECMO) is a temporary, but prolonged circulatory support for cardiopulmonary failure. Clinical evidence suggests that pulsed flow is healthier than non pulsatile perfusion. The aim of this study was to computationally evaluate the effects of total and partial ECMO assistance and pulsed flow on hemodynamics in a patient-specific aorta model. The pulsatility was obtained by means of the intra-aortic balloon pump (IABP), and two different cases were investigated, considering a cardiac output (CO) of 5 L/min: Case A - total assistance - the whole flow delivered through the ECMO arterial cannula; Case B - partial assistance - flow delivered half through the cannula and half through the aorta. Computational fluid dynamic (CFD) analysis was carried out using the multiscale approach to couple the 3D aorta model with the lumped parameter model (resistance boundary condition). In case A pulsatility followed the balloon radius change, while in case B it was mostly influenced by the cardiac one. Furthermore, during total assistance, a blood stagnation occurred in the ascending aorta; in the case of partial assistance, the flow was orderly when the IABP was on and was chaotic when the balloon was off. Moreover, the mean arterial pressure (MAP) was higher in case B. The wall shear stress was worse in ascending aorta in case A. Partial support is hemodynamically advisable.
Schampaert, Stéphanie; Rutten, Marcel C M; van T Veer, Marcel; van Nunen, Lokien X; Tonino, Pim A L; Pijls, Nico H J; van de Vosse, Frans N
2013-01-01
Because of the large number of interaction factors involved, the effects of the intra-aortic balloon pump (IABP) have not been investigated deeply. To enhance its clinical efficiency and to better define indications for use, advanced models are required to test the interaction between the IABP and the cardiovascular system. A patient with mild blood pressure depression and a lowered cardiac output is modeled in a lumped parameter computational model, developed with physiologically representative elements for relevant components of circulation and device. IABP support is applied, and the moments of balloon inflation and deflation are varied around their conventional timing modes. For validation purposes, timing is adapted within acceptable ranges in ten patients undergoing IABP therapy for typical clinical indications. In both model and patients, the IABP induces a diastolic blood pressure augmentation as well as a systolic reduction in afterload. The support capabilities of the IABP benefit the most when the balloon is deflated simultaneously with ventricular contraction, whereas inflation before onset of diastole unconditionally interferes with ejection. The physiologic response makes the model an excellent tool for testing the interaction between the IABP and the cardiovascular system, and how alterations of specific IABP parameters (i.e., timing) affect this coupling.
Malliaras, Konstantinos; Charitos, Efstratios; Diakos, Nikolaos; Pozios, Iraklis; Papalois, Apostolos; Terrovitis, John; Nanas, John
2014-12-01
We investigated the effects of intra-aortic balloon pump (IABP) counterpulsation on left ventricular (LV) contractility, relaxation, and energy consumption and probed the underlying physiologic mechanisms in 12 farm pigs, using an ischemia-reperfusion model of acute heart failure. During both ischemia and reperfusion, IABP support unloaded the LV, decreased LV energy consumption (pressure-volume area, stroke work), and concurrently improved LV mechanical performance (ejection fraction, stroke volume, cardiac output). During reperfusion exclusively, IABP also improved LV relaxation (tau) and contractility (Emax, PRSW). The beneficial effects of IABP support on LV relaxation and contractility correlated with IABP-induced augmentation of coronary blood flow. In conclusion, we find that during both ischemia and reperfusion, IABP support optimizes LV energetic performance (decreases energy consumption and concurrently improves mechanical performance) by LV unloading. During reperfusion exclusively, IABP support also improves LV contractility and active relaxation, possibly due to a synergistic effect of unloading and augmentation of coronary blood flow.
Predictors of Intra-Aortic Balloon Pump Insertion in Coronary Surgery and Mid-Term Results
Yurekli, Ismail; Celik, Ersin; Yetkin, Ufuk; Yilik, Levent; Gurbuz, Ali
2013-01-01
Background We aimed to investigate the preoperative, operative, and postoperative factors affecting intra-aortic balloon pump (IABP) insertion in patients undergoing isolated on-pump coronary artery bypass grafting (CABG). We also investigated factors affecting morbidity, mortality, and survival in patients with IABP support. Methods Between January 2002 and December 2009, 1,657 patients underwent isolated CABG in İzmir Katip Celebi University Atatürk Training and Research Hospital. The number of patients requiring support with IABP was 134 (8.1%). Results In a multivariate logistic regression analysis, prolonged cardiopulmonary bypass time and prolonged operation time were independent predictive factors of IABP insertion. The postoperative mortality rate was 35.8% and 1% in patients with and without IABP support, respectively (p=0.000). Postoperative renal insufficiency, prolonged ventilatory support, and postoperative atrial fibrillation were independent predictive factors of postoperative mortality in patients with IABP support. The mean follow-up time was 38.55±22.70 months and 48.78±25.20 months in patients with and without IABP support, respectively. The follow-up mortality rate was 3% (n=4) and 5.3% (n=78) in patients with and without IABP support, respectively. Conclusion The patients with IABP support had a higher postoperative mortality rate and a longer length of intensive care unit and hospital stay. The mid-term survival was good for patients surviving the early postoperative period. PMID:24368971
Kiuchi, Ryuta; Tomita, Shigeyuki; Yamaguchi, Shojiro; Nishida, Yuji; Ohtake, Hiroshi; Nakamura, Hiroyuki; Watanabe, Go
2014-07-01
It is important for coronary active perfusion systems to avoid myocardial ischemia during off-pump coronary artery bypass grafting. We have developed a new concept for a perfusion system to pump blood based on changes in helium gas volume. This system uses a conventional intra-aortic balloon pump to activate the perfusion pump. Our study used basic and animal experiments to investigate the most suitable system for coronary perfusion using this new concept. A conventional intra-aortic balloon pump was used to supply power. A device for perfusion was developed with a balloon placed inside a stiff syringe barrel. The device was connected to the helium gas line of the intra-aortic balloon pump. Changes in flow with changes in augmentation level were noted when volumes outside and within the balloon were changed. Six pigs with occlusion of the left anterior descending artery were used for system validation, with monitoring to identify changes in hemodynamics and cardiac enzyme levels. In the basic experiment, an 80-mL outside volume and 3.0-mL inner volume resulted in the greatest percentage change in flow rate with respect to changes in augmentation. In the animal experiment, the new coronary active perfusion system prevented myocardial ischemia during coronary occlusion. We clarified the most suitable method for our new coronary active perfusion system. Using this system, safe anastomosis was consistently performed in animal experiments. Clinically, off-pump coronary artery bypass may potentially be performed more safely and easily using this new system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Rathod, Krishnaraj S; Koganti, Sudheer; Iqbal, M Bilal; Jain, Ajay K; Kalra, Sundeep S; Astroulakis, Zoe; Lim, Pitt; Rakhit, Roby; Dalby, Miles C; Lockie, Tim; Malik, Iqbal S; Knight, Charles J; Whitbread, Mark; Mathur, Anthony; Redwood, Simon; MacCarthy, Philip A; Sirker, Alexander; O'Mahony, Constantinos; Wragg, Andrew; Jones, Daniel A
2018-02-01
Cardiogenic shock remains a major cause of morbidity and mortality in patients with ST-segment elevation myocardial infarction. We aimed to assess the current trends in cardiogenic shock management, looking specifically at the incidence, use of intra-aortic balloon pump therapy and outcomes in patients with ST-segment elevation myocardial infarction treated with primary percutaneous coronary intervention. We undertook an observational cohort study of 21,210 ST-segment elevation myocardial infarction patients treated between 2005-2015 at the eight Heart Attack Centres in London, UK. Patients' details were recorded at the time of the procedure into local databases using the British Cardiac Intervention Society percutaneous coronary intervention dataset. There were 1890 patients who presented with cardiogenic shock. The primary outcome was all-cause mortality at a median follow-up of 4.1 years (interquartile range: 2.2-5.8 years). Increasing rates of cardiogenic shock were seen over the course of the study with consistently high mortality rates of 45-70%. A total of 685 patients underwent intra-aortic balloon pump insertion during primary percutaneous coronary intervention for cardiogenic shock with decreasing rates over time. Those patients undergoing intra-aortic balloon pump therapy were younger, more likely to have poor left ventricular function and less likely to have had previous percutaneous coronary intervention compared to the control group. Procedural success rates were similar (86.0% vs 87.1%, p=0.292) although crude, in-hospital major adverse cardiac event rates were higher (43.8% vs 33.7%, p<0.0001) in patients undergoing intra-aortic balloon pump therapy. Kaplan-Meier analysis demonstrated significantly higher mortality rates in patients receiving intra-aortic balloon pump therapy (50.9% intra-aortic balloon pump vs 39.9% control, p<0.0001) during the follow-up period. After multivariate Cox analysis (hazard ratio 1.04, 95% confidence interval 0.62-1.89) and the use of propensity matching (hazard ratio: 1.29, 95% confidence interval: 0.68-1.45) intra-aortic balloon pump therapy was not associated with mortality. Cardiogenic shock treated by percutaneous coronary intervention is increasing in incidence and remains a condition associated with high mortality and limited treatment options. Intra-aortic balloon pump therapy was not associated with a long-term survival benefit in this cohort and may be associated with increased early morbidity.
Efficacy of a new intraaortic propeller pump vs the intraaortic balloon pump: an animal study.
Dekker, André; Reesink, Koen; van der Veen, Erik; Van Ommen, Vincent; Geskes, Gijs; Soemers, Cecile; Maessen, Jos
2003-06-01
To compare the efficacy of a new intraaortic propeller pump (PP) to provide hemodynamic support to the intraaortic balloon pump (IABP) in an acute mitral regurgitation (MR) animal model. A new intraaortic PP (Reitan catheter pump; Jomed; Helsingborg, Sweden) recently has been introduced. The pump's aim is a reduction in afterload via a deployable propeller that is placed in the high descending aorta and can be set at rotational speeds of
Analysis of intra-aortic balloon pump model with ovine myocardial infarction.
Abdolrazaghi, Mona; Navidbakhsh, Mahdi; Hassani, Kamran; Rabbani, Shahram; Ahmadi, Hossein
2009-12-01
In this study, we have tried to model the effects of intra-aortic balloon pump (IABP) on myocardial infarction (MI) using the standardized data of MI in sheep which was obtained by ligation of the left anterior descending coronary artery. Mathematical model of whole cardiovascular system was presented in accordance to the arterial tree. The lumped parameter model was primarily obtained for a rigid vessel regarding the vessel diameter. In this study, the proper lumped model of every vessel was obtained by incorporating the rigid vessel lumped model into the capacitance as a compliance of the vessel. Intra-aortic balloon pump was modeled with the hemodynamic parameters of the aorta. It was assumed that balloon pump inflates at the beginning of the diastole and deflates near the beginning of the next systole. During balloon pumping, the vessel diameter variation function counter pulsates sinusoidally with the same period of the cardiac cycle. End systolic pressure and end diastolic pressure decreases along with hemodynamic flow optimized through systemic arteries due to balloon pumping in diastole. It has been shown that the blood flow in subclavian artery increases as well. Moreover, the cardiac work keeps low, which prone to lower oxygen consumption. The results of modeling are in good agreement with IABP documentation. The presented model is a useful tool for studying of the cardiovascular system pathology and the presented modeling data are in good agreement with the experimental ones.
Temporary Mechanical Circulatory Support: A Review of the Options, Indications, and Outcomes
Gilotra, Nisha A; Stevens, Gerin R
2014-01-01
Cardiogenic shock remains a challenging disease entity and is associated with significant morbidity and mortality. Temporary mechanical circulatory support (MCS) can be implemented in an acute setting to stabilize acutely ill patients with cardiomyopathy in a variety of clinical situations. Currently, several options exist for temporary MCS. We review the indications, contraindications, clinical applications, and evidences for a variety of temporary circulatory support options, including the intra-aortic balloon pump (IABP), extracorporeal membrane oxygenation (ECMO), CentriMag blood pump, and percutaneous ventricular assist devices (pVADs), specifically the TandemHeart and Impella. PMID:25674024
Isothermal pumping analysis for high-altitude tethered balloons
Kuo, Kirsty A.; Hunt, Hugh E. M.
2015-01-01
High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal analysis is used to determine the variation of pressures and velocities along the pipe length. Results show that transport of small quantities of hydrogen to power fuel cells and maintain balloon buoyancy can be achieved at pressures and temperatures that are tolerable in terms of both the pipe strength and the current state of pumping technologies. To avoid solidification, transport of SO2 would require elevated temperatures that cannot be tolerated by the strength fibres in the pipe. While the use of particle-based slurries rather than SO2 for climate engineering can reduce the pipe size significantly, the pumping pressures are close to the maximum bursting pressure of the pipe. PMID:26543573
Isothermal pumping analysis for high-altitude tethered balloons.
Kuo, Kirsty A; Hunt, Hugh E M
2015-06-01
High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal analysis is used to determine the variation of pressures and velocities along the pipe length. Results show that transport of small quantities of hydrogen to power fuel cells and maintain balloon buoyancy can be achieved at pressures and temperatures that are tolerable in terms of both the pipe strength and the current state of pumping technologies. To avoid solidification, transport of SO2 would require elevated temperatures that cannot be tolerated by the strength fibres in the pipe. While the use of particle-based slurries rather than SO2 for climate engineering can reduce the pipe size significantly, the pumping pressures are close to the maximum bursting pressure of the pipe.
Use of mechanical devices for distal hemoperfusion during balloon catheter coronary angioplasty.
Heibig, J; Angelini, P; Leachman, D R; Beall, M M; Beall, A C
1988-01-01
Previous attempts to protect the dependent myocardium during balloon catheter coronary angioplasty in animals and humans have had generally unsatisfactory results. This paper summarizes the authors' experience in investigating commercially available mechanical pumps for distal coronary hemoperfusion during balloon angioplasty. Both roller and piston pumps can attain adequate distal perfusion without significant side effects in the majority of patients. Our goal was to suppress angina for at least 5 min to prolong balloon inflation in awake patients. Minor T-wave changes without concomitant angina pectoris can be expected when the distal coronary bed is perfused with hypothermic blood. Side branch occlusion by the inflated balloon prevents effective protection of the corresponding part of the dependent myocardium during distal hemoperfusion, which may result in persistent angina and ST-T changes uncorrected by increasing the hemoperfusion rate. Distal coronary diffuse spasm, rare and transient, was the only immediate complication of this procedure. It is suggested that intense local wall stimulation could occur with a higher flow rate (jet effect). Improved balloon catheter pressure/flow characteristics and on-line continuous mechanical pumps should soon make distal coronary hemoperfusion through balloon catheters an accepted clinical technique.
Ntalianis, Argyrios S; Drakos, Stavros G; Charitos, Christos; Dolou, Paraskevi; Pierrakos, Charalampos N; Terrovitis, John V; Papaioannou, Theodoros; Charitos, Efstratios; Nanas, John N
2008-01-01
The present experimental study compared the effectiveness of counterpulsation provided by the intra-aortic balloon pump (IABP) versus that of a nonpulsatile, radial-flow centrifugal pump (CFP) in rapidly worsening acute heart failure (HF). Eighteen pigs were included in the study. After the induction of acute moderate HF, circulatory support was randomly provided with either the IABP or CFP. No significant change in cardiac output (CO) and mean aortic pressure (MAP) was observed with either pump. The IABP caused a significantly greater decrease than the CFP in 1) double product (13.138 +/- 2.476 mm Hg/min vs. 14.217 +/- 2.673 mm Hg/min, p = 0.023), 2) left ventricular systolic pressure (LVSP, 100 +/- 8 mm Hg vs. 106 +/- 10 mm Hg, p = 0.046), and 3) end-diastolic aortic pressure (EDAP, 70 +/- 6 mm Hg vs. 86 +/- 6 mm Hg, p = 0.000). The effects of both pumps on total tension time index and LAD flow were similar. After the induction of severe HF, the IABP had its main effects on afterload and decreased LVSP from 88 +/- 6 mm Hg to 78 +/- 9 mm Hg, (p = 0.008), and EDAP from 57 +/- 9 mm Hg to 49 +/- 14 mm Hg, (p = 0.044), whereas the CFP exerted its effects mainly on preload, lowering LV end-diastolic pressure from 19 +/- 5 mm Hg to 11 +/- 4 mm Hg, (p = 0.002). CO and MAP were similarly increased by both assist systems. The IABP (by lowering afterload) and CFP (by lowering preload) both offered significant mechanical support in acute HF. However, afterload reduction offered principally by the IABP seems preferable for the recovery of the acutely failing heart.
Wave energy patterns of counterpulsation: a novel approach with wave intensity analysis.
Lu, Pong-Jeu; Yang, Chi-Fu Jeffrey; Wu, Meng-Yu; Hung, Chun-Hao; Chan, Ming-Yao; Hsu, Tzu-Cheng
2011-11-01
In counterpulsation, diastolic augmentation increases coronary blood flow and systolic unloading reduces left ventricular afterload. We present a new approach with wave intensity analysis to revisit and explain counterpulsation principles. In an acute porcine model, a standard intra-aortic balloon pump was placed in descending aorta in 4 pigs. We measured pressure and velocity with probes in left anterior descending artery and aorta during and without intra-aortic balloon pump assistance. Wave intensities of aortic and left coronary waves were derived from pressure and flow measurements with synchronization correction. We identified predominating waves in counterpulsation. In the aorta, during diastolic augmentation, intra-aortic balloon inflation generated a backward compression wave, with a "pushing" effect toward the aortic root that translated to a forward compression wave into coronary circulation. During systolic unloading, intra-aortic balloon pump deflation generated a backward expansion wave that "sucked" blood from left coronary bed into the aorta. While this backward expansion wave translated to reduced left ventricular afterload, the "sucking" effect resulted in left coronary blood steal, as demonstrated by a forward expansion wave in left anterior descending coronary flow. The waves were sensitive to inflation and deflation timing, with just 25 ms delay from standard deflation timing leading to weaker forward expansion wave and less coronary regurgitation. Intra-aortic balloon pumps generate backward-traveling waves that predominantly drive aortic and coronary blood flow during counterpulsation. Wave intensity analysis of arterial circulations may provide a mechanism to explain diastolic augmentation and systolic unloading of intra-aortic balloon pump counterpulsation. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Cerebral hemodynamics with intra-aortic balloon pump: business as usual?
Caldas, J R; Panerai, R B; Bor-Seng-Shu, E; Almeida, J P; Ferreira, G S R; Camara, L; Nogueira, R C; Oliveira, M L; Jatene, F B; Robinson, T G; Hajjar, L A
2017-06-22
Intra-aortic balloon pump (IABP) is commonly used as mechanical support after cardiac surgery or cardiac shock. Although its benefits for cardiac function have been well documented, its effects on cerebral circulation are still controversial. We hypothesized that transfer function analysis (TFA) and continuous estimates of dynamic cerebral autoregulation (CA) provide consistent results in the assessment of cerebral autoregulation in patients with IABP. Continuous recordings of blood pressure (BP, intra-arterial line), end-tidal CO 2 , heart rate and cerebral blood flow velocity (CBFV, transcranial Doppler) were obtained (i) 5 min with IABP ratio 1:3, (ii) 5 min, starting 1 min with the IABP-ON, and continuing for another 4 min without pump assistance (IABP-OFF). Autoregulation index (ARI) was estimated from the CBFV response to a step change in BP derived by TFA and as a function of time using an autoregressive moving-average model during removal of the device (ARI t ). Critical closing pressure and resistance area-product were also obtained. ARI with IABP-ON (4.3 ± 1.2) were not different from corresponding values at IABP-OFF (4.7 ± 1.4, p = 0.42). Removal of the balloon had no effect on ARI t , CBFV, BP, cerebral critical closing pressure or resistance area-product. IABP does not disturb cerebral hemodynamics. TFA and continuous estimates of dynamic CA can be used to assess cerebral hemodynamics in patients with IABP. These findings have important implications for the design of studies of critically ill patients requiring the use of different invasive support devices.
Dekker, André L A J; Reesink, Koen D; van der Veen, Frederik H; van Ommen, G Vincent A; Geskes, Gijs G; Soemers, A Cecilia M; Maessen, Jos G
2003-04-01
Acute mitral regurgitation (MR) is present in 10% of patients presenting with cardiogenic shock. To stabilize these patients, intra-aortic balloon pumping (IABP) is recommended, but the mechanism of IABP support in these patients is unknown. This animal study was designed to describe the hemodynamic effect of intra-aortic balloon pumping during cardiogenic shock induced by acute MR. In eight calves, left ventricular pressure-volume loops, aortic and left atrial pressure, and aortic, carotid artery, and coronary blood flow were recorded. Acute MR (range 36%-79%) was created by placing a metal cage in the mitral valve. Hemodynamic data was obtained at control, during acute MR, and during acute MR with 1:1 IABP support. Acute MR caused a decrease in cardiac output (-32%, P = 0.018), blood pressure, and carotid artery flow, whereas left ventricular output (+127%, P = 0.018), end-diastolic volume, and left atrial pressure all significantly increased. Stroke work, ejection fraction, and coronary blood flow were not significantly changed, and no signs of ischemia were seen on the ECG. The IABP raised average cardiac output by 31% (P = 0.012) and significantly raised blood pressure and flow to the brain while decreasing systemic vascular resistance. Left ventricular function and mean coronary blood flow did not change, but diastolic coronary flow became more important as shown by the increase in diastolic fraction from 64% to 95%. (P = 0.028). Average MR dropped by 7.5% (P = 0.025). In conclusion, application of the IABP during acute MR lowers aortic impedance, resulting in less MR and more output toward the aorta without changing left ventricular function.
Kuki, S; Taniguchi, K; Masai, T; Yoshida, K; Yamamoto, K; Matsuda, H
2001-01-01
The most important limitation in the use of an intra-aortic balloon pumping (IABP) is the risk of vascular complications. Recently, an IABP catheter with an 8.0 French shaft and low profile that may decrease the risk of vascular morbidity has been developed. We evaluated the in vitro balloon performance and the prevention of limb ischemia in clinical use. An 8.0 French IABP catheter was compared with a standard 9.5 French catheter. Inflation time (IT), deflation time (DT), and changes in volume (V) generated by the balloon were measured during the pumping cycle in an experimental model. The inflation velocity (V/IT) and deflation velocity (V/DT) were calculated as parameters of balloon performance. At 120 bpm the V/IT and V/DT were 0.34 ml/msec and 0.28 ml/msec with the 8.0 French, and 0.33 ml/msec and 0.24 ml/msec with the 9.5 French catheter. Twelve patients with coronary artery disease, ranging in age from 41 to 87 years (mean, 66 years), who underwent IABP support, were divided into group 1 (8.0 French, n = 4) and group 2 (9.5 French, n = 8). Ankle-arm pressure index (API), lactate extraction ratio (LER) in the limb with IABP insertion, and cardiac index (CI) were measured at 1, 12, and 24 hours postoperatively. There were no major vascular complications and no counterpulsation related morbidity. There was no significant difference between the two groups with regard to age, duration of IABP support, and incidence of peripheral vascular disease and diabetes. The percentage of women patients was significantly higher in group 1 (100% vs. 25%), whereas body surface area was significantly smaller (1.45 +/- 0.14 vs. 1.68 +/- 0.12 m2). The API in group 1 were slightly higher than those in group 2 throughout the observed period (not significant). The LER and Cl showed no significant differences between the two groups. These results suggest that the 8.0 French IABP catheter with a low profile has an acceptable in vitro performance, and its clinical application may be effective in preventing limb ischemia in a high-risk subset of patients such as women and smaller patients.
Barkhordari, Khosro; Yousefshahi, Fardin; Khajavi, Mohammad Reza; Karimi, Abbasali
2012-06-01
Compartment syndrome is a rare, devastating complication of coronary artery bypass grafting (CABG) and intra-aortic balloon pump (IABP). Prompt diagnosis is based on symptoms and signs and is paramount for limb rescue. This report describes a CABG patient with IABP in whom receiving continuous analgesia-sedation obscured the symptoms of compartment syndrome.
Lifting options for stratospheric aerosol geoengineering: advantages of tethered balloon systems.
Davidson, Peter; Burgoyne, Chris; Hunt, Hugh; Causier, Matt
2012-09-13
The Royal Society report 'Geoengineering the Climate' identified solar radiation management using albedo-enhancing aerosols injected into the stratosphere as the most affordable and effective option for geoengineering, but did not consider in any detail the options for delivery. This paper provides outline engineering analyses of the options, both for batch-delivery processes, following up on previous work for artillery shells, missiles, aircraft and free-flying balloons, as well as a more lengthy analysis of continuous-delivery systems that require a pipe connected to the ground and supported at a height of 20 km, either by a tower or by a tethered balloon. Towers are shown not to be practical, but a tethered balloon delivery system, with high-pressure pumping, appears to have much lower operating and capital costs than all other delivery options. Instead of transporting sulphuric acid mist precursors, such a system could also be used to transport slurries of high refractive index particles such as coated titanium dioxide. The use of such particles would allow useful experiments on opacity, coagulation and atmospheric chemistry at modest rates so as not to perturb regional or global climatic conditions, thus reducing scale-up risks. Criteria for particle choice are discussed, including the need to minimize or prevent ozone destruction. The paper estimates the time scales and relatively modest costs required if a tethered balloon system were to be introduced in a measured way with testing and development work proceeding over three decades, rather than in an emergency. The manufacture of a tether capable of sustaining the high tensions and internal pressures needed, as well as strong winds, is a significant challenge, as is the development of the necessary pumping and dispersion technologies. The greatest challenge may be the manufacture and launch of very large balloons, but means have been identified to significantly reduce the size of such balloons or aerostats.
Initial clinical trial of a closed loop, fully automatic intra-aortic balloon pump.
Kantrowitz, A; Freed, P S; Cardona, R R; Gage, K; Marinescu, G N; Westveld, A H; Litch, B; Suzuki, A; Hayakawa, H; Takano, T
1992-01-01
A new generation, closed loop, fully automatic intraaortic balloon pump (CL-IABP) system continuously optimizes diastolic augmentation by adjusting balloon pump parameters beat by beat without operator intervention. In dogs in sinus rhythm and with experimentally induced arrhythmias, the new CL-IABP system provided safe, effective augmentation. To investigate the system's suitability for clinical use, 10 patients meeting standard indications for IABP were studied. The patients were pumped by the fully automatic IABP system for an average of 20 hr (range, 1-48 hr). At start-up, the system optimized pumping parameters within 7-20 sec. Evaluation of 186 recordings made at hourly intervals showed that inflation began within 20 msec of the dicrotic notch 99% of the time. In 100% of the recordings, deflation straddled the first half of ventricular ejection. Peak pressure across the balloon membrane averaged 55 mmHg and, in no case, exceeded 100 mmHg. Examination of the data showed that as soon as the system was actuated it provided consistently beneficial diastolic augmentation without any further operator intervention. Eight patients improved and two died (one of irreversible cardiogenic shock and one of ischemic cardiomyopathy). No complications were attributable to the investigational aspects of the system. A fully automated IABP is feasible in the clinical setting, and it may have advantages relative to current generation IABP systems.
Umakanthan, Ramanan; Dubose, Robert; Byrne, John G; Ahmad, Rashid M
2010-10-01
The management of acute myocardial infarction with resultant acute ischemic mitral regurgitation and acute multi-organ failure can prove to be a very challenging scenario. The presence of concomitant vascular disease can only serve to further compromise the complexity of the situation. We demonstrate a new indication for the transthoracic intra-aortic balloon pump as a preoperative means of unloading the heart and improving clinical outcome in such high-risk patients with severe vascular disease. We present the case of a 75-year-old man with a history of severe vascular disease who was transferred emergently to Vanderbilt University Medical Center with an acute inferolateral wall myocardial infarction resulting in severe acute ischemic mitral regurgitation and acute multi-organ failure. He presented with shock liver (serum glutamic-oxaloacetic transaminase [SGOT] of 958), renal failure (creatinine of 3.0), and respiratory failure with a pH of 7.18. Emergent cardiac catheterization revealed 100% occlusion of the left circumflex artery as well as severe ileofemoral disease. The advanced nature of his ileofemoral disease was such that the arterial access catheter occluded the right femoral artery. The duration of time that the catheter was in the artery led to transient limb ischemia with an elevation of his creatine phosphokinase (CPK) to 10,809. Balloon angioplasty followed by stent placement was successfully performed, which restored flow to the coronary vessel. Given the grave nature of the patient's condition, we were very concerned that immediate operative intervention for his condition would entail prohibitively high risk. In fact, the Society of Thoracic Surgeons predicted risk adjusted mortality was calculated to be 56%. In order to minimize patient mortality and morbidity, it was critical to help restore perfusion and organ recovery. Therefore, we decided that the chances for this patient's survival would improve if his condition could be optimized by placement of an intra-aortic balloon pump before undergoing surgery. Given the limb ischemia following arterial sheath insertion, femoral placement of an intra-aortic balloon pump was not an option. Placement of the intra-aortic balloon pump was attempted via a left subclavian artery cutdown, but was not successful. Therefore, a sternotomy was performed, and we placed a transthoracic intra-aortic balloon pump in order to stabilize the patient's hemodynamics and allow for organ recovery. The patient showed immediate improvement, and 4 days later, the multi-organ failure resolved and he successfully underwent mitral valve replacement. The patient was ultimately discharged to a local rehabilitation facility in satisfactory condition. This case demonstrates the utility of a transthoracic intra-aortic balloon pump as a preoperative means of stabilization in very high risk patients with severe peripheral vascular disease in whom the conventional approaches are not possible.
A Numerical Modeling of A Vascular Implantable Cardiac Endovascular Assistant (AVICENA)
NASA Astrophysics Data System (ADS)
Rahmani, Shahrokh; Tehrani, Pedram; Karimi, Alireza; Alizadeh, Mansour; Navidbakhsh, Mahdi
2015-10-01
Cardiovascular diseases have been recently shown to have a pivotal role in human death and endangers lives of many people around the world. One of the most common cardiovascular diseases is poor performance of left ventricle. In this case, the ventricle cannot pump the blood into the aorta and circulatory system with a suitable power which is required for normal circulatory system. AVICENA is a new cardiac assist device which is implanted into the aorta to help the ventricle to pump the blood into circulatory system with more power and to make a better perfusion of the coronary arteries as well. To reach a desire value of rotational speed of the pump, a control circuit is designed for counterpulsation of AVICENA based on the outcomes from previous studies. This control circuit uses a PID controller. The present study aims to simulate the blood flow through the balloon part of AVICENA in a heart cycle with focusing on the calculation of its pump rotational speed by controlling the electrical current of the pump. Results revealed that the desired rotational speed of the pump can be achieved according to the previous aorta pressure cycle by electrical current control which is higher during balloon inflation in comparison with balloon deflation. These findings may have implications not only for understanding the performance of AVICENA but also to help cardiac mechanics experts to improve the shortcoming of this newborn device.
Marks, J D; Pantalos, G M; Long, J W; Kinoshita, M; Everett, S D; Olsen, D B
1999-01-01
Unlike the mechanisms of intraaortic balloon pump (IABP) support, the mechanisms by which transvalvular axial flow Hemopump (HP) support benefit dysfunctional myocardium are less clearly understood. To help elucidate these mechanisms, hemodynamic, metabolic, and mechanical indexes of left ventricular function were measured during conditions of control, ischemic dysfunction, IABP support, and HP support. A large animal (calf) model of left ventricular dysfunction was created with multiple coronary ligations. Peak intraventricular pressure increased with HP support and decreased with IABP support. Intramyocardial pressure (an indicator of intramyocardial stress), time rate of pressure change (an indicator of contractility), and left ventricular myocardial oxygen consumption decreased with IABP and HP support. Left ventricular work decreased with HP support and increased with IABP support. During HP support, indexes of wall stress, work, and contractility, all primary determinants of oxygen consumption, were reduced. During IABP support, indexes of wall stress and contractility were reduced and external work increased. These changes were attributed primarily to changes in ventricular preload, and geometry for HP support, and to a reduction in afterload for IABP support. These findings support the hypothesis that both HP and IABP support reduce intramyocardial stress development and the corresponding oxygen consumption, although via different mechanisms.
Effects of intra-aortic counterpulsation on aortic wall energetics and damping: in vivo experiments.
Fischer, Edmundo I Cabrera; Bia, Daniel; Camus, Juan M; Zócalo, Yanina; de Forteza, Eduardo; Armentano, Ricardo L
2008-01-01
Intra-aortic balloon pumping (IABP) could modify the arterial biomechanics; however, its effects on arterial wall properties have not been fully explored. This dynamical study was designed to characterize the pressure-dependent and smooth muscle-dependent effects of IABP on aortic wall energetics in an in vivo animal model. Intra-aortic balloon pumping (1:2) was performed in six anesthetized sheep in which aortic pressure and diameter signals were measured in basal, augmented (during balloon inflation), and assisted (postaugmented) beats. Energy dissipation values in augmented and assisted beats were significantly higher than those observed in basal state (p < 0.05). Assisted beats showed a significant increase of wall damping with respect to basal and augmented beats (p < 0.05). Intra-aortic balloon pumping resulted in a significant increase of pulse wave velocity (p < 0.05) in augmented beats with respect to basal state (6.3 +/- 0.8 vs. 5.2 +/- 0.5 m x s(-1)); whereas values observed in assisted beats were significantly (p < 0.05) lower than those observed in augmented beats (4.9 +/- 0.5 vs. 6.3 +/- 0.8 m x s(-1)). Our findings show that IABP determined the pressure and smooth muscle-dependent changes in arterial wall energetics and damping properties in this animal model.
Rihal, Charanjit S; Naidu, Srihari S; Givertz, Michael M; Szeto, Wilson Y; Burke, James A; Kapur, Navin K; Kern, Morton; Garratt, Kirk N; Goldstein, James A; Dimas, Vivian; Tu, Thomas
2015-06-01
Although historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella(®); left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability. This document reviews the physiologic impact on the circulation of these devices and their use in specific clinical situations. These situations include patients undergoing high-risk percutaneous coronary intervention, those presenting with cardiogenic shock, and acute decompensated heart failure. Specialized uses for right-sided support and in pediatric populations are discussed and the clinical utility of mechanical circulatory support devices is reviewed, as are the American College of Cardiology/American Heart Association clinical practice guidelines. Copyright © 2015. Published by Elsevier Inc.
Timing of intra-aortic balloon pump support and 1-year survival.
Ramnarine, Ian R; Grayson, Antony D; Dihmis, Walid C; Mediratta, Neeraj K; Fabri, Brian M; Chalmers, John A C
2005-05-01
The relationship between the timing of intra-aortic balloon pump (IABP) support and surgical outcome remains a subject of debate. Peri-operative mechanical circulatory support is commenced either prophylactically or after increasing inotropic support has proved inadequate. This study evaluates the effect timing of IABP support on the 1-year survival of patients undergoing cardiac surgery. From April 1997 to September 2002, 7698 consecutive cardiac surgical procedures were performed. This included 5678 isolated coronary artery bypasses (CABGs), 1245 isolated valve procedures and 775 simultaneous CABG and valve procedures. IABP support was required in 237 patients (3.1%). Twenty-seven patients (0.35%) were classed as high-risk and received preoperative IABP support, 25 patients (0.32%) were haemodynamically compromised and required preoperative IABP support, 120 patients (1.56%) required intra-operative IABP support, and 65 patients (0.84%) required post-operative IABP support. Multiple variables were offered to a Cox proportional hazards model and significant predictors of 1-year survival were identified. These were used to risk adjust Kaplan-Meier survival curves. 1-year follow-up was complete and 450 deaths (5.8%) were recorded. The significant independent predictors of increased mortality at 1-year (P<0.05, HR=hazard ratio) were post-operative renal failure (HR=3.5), increasing EuroSCORE (HR=1.2), post-operative myocardial infarction (HR=3.7), post-operative IABP (HR=4.1) intra-operative IABP (HR=2.8), post-operative stroke (HR=2.5), increasing number of valves (HR=1.6), ejection fraction <30% (HR=1.3) and triple-vessel disease (HR=1.3). After risk-adjustment, 1-year survival for patients who required intra-operative IABP support was significantly greater than for those patients who required IABP support in the post-operative period. Patients who warrant IABP support in the post-operative setting have a significantly increased mortality at 1-year when compared to any other group. Therefore, earlier IABP support as part of surgical strategy may help to improve the outcome.
2014-01-01
Background There is no available data on clinical outcome in patients with acute myocardial infarction (AMI) complicated by cardiogenic shock who are supported by an intra-aortic balloon pump (IABP) in combination with extracorporeal life support (ECLS). Methods We analysed 96 consecutive patients with AMI and complicating cardiogenic shock who were assisted by an ECLS system between January 2004 and December 2011. The primary outcome was in-hospital mortality. The secondary outcomes were the success rate of weaning from ECLS and the lactate clearance for 48 hours (%). Results A combination of IABP and ECLS was used in 41 (42.7%) patients. In-hospital mortality occurred for 51 patients (ECLS with IABP versus ECLS alone; 51.2% vs. 54.5%, p = 0.747). The success rate of weaning from ECLS was similar between the two groups (63.4% vs. 58.2%, p = 0.604). Complications such as ischemia of a lower extremity or bleeding at the ECLS insertion site (p = 0.521 and p = 0.667, respectively) did not increase when ECLS was combined with IABP. Among patients who survived for 24 hours after intervention, lactate clearance was not significantly different between patients who received ECLS alone and those who received ECLS with IABP (p = 0.918). Conclusions The combined use of ECLS and IABP did not improve in-hospital survival in patients with AMI complicated by cardiogenic shock. PMID:24725532
Intra-Aortic Balloon Pump Malposition Reduces Visceral Artery Perfusion in an Acute Animal Model.
Vondran, Maximilian; Rastan, Ardawan J; Tillmann, Eugen; Seeburger, Jörg; Schröter, Thomas; Dhein, Stefan; Bakhtiary, Farhad; Mohr, Friedrich-Wilhelm
2016-04-01
Visceral artery perfusion can be potentially affected by intra-aortic balloon pump (IABP) catheters. We utilized an animal model to quantify the acute impact of a low balloon position on mesenteric artery perfusion. In six pigs (78 ± 7 kg), a 30-cc IABP was placed in the descending aorta in a transfemoral procedure. The celiac artery (CA) and the cranial mesenteric artery (CMA) were surgically dissected. Transit time blood flow was measured for (i) baseline, (ii) 1:1 augmentation with the balloon proximal to the visceral arteries, and (iii) 1:1 augmentation with the balloon covering the visceral arteries. Blood flow in the CMA and CA was reduced by 17 and 24%, respectively, when the balloon compromised visceral arteries compared with a position above the visceral arteries (flow in mL/min: CMA: (i) 1281 ± 512, (ii) 1389 ± 287, (iii) 1064 ± 276, P < 0.05 for 3 vs. 1 and 3 vs. 2; CA: (i) 885 ± 370, (ii) 819 ± 297, (iii) 673 ± 315; P < 0.05 for 3 vs. 1). The covering of visceral arteries by an IABP balloon causes a significant reduction of visceral artery perfusion; thus, the positioning of this device during implantation is critical for obtaining a satisfactory outcome. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Options for temporary mechanical circulatory support
Saffarzadeh, Areo
2015-01-01
Temporary mechanical circulatory support (MCS) refers to a group of devices generally used for less than 30 days to maintain adequate organ perfusion by compensating for a failure of the pumping mechanism of the heart. The increased availability and rapid adoption of new temporary MCS strategies necessitate physicians to become familiar with devices placed both percutaneously and via median sternotomy. This review will examine the different options for commonly used temporary MCS devices including intra-aortic balloon pumps (IABPs), veno-arterial-extracorporeal membrane oxygenation (VA-ECMO), TandemHeart® (CardiacAssist, Pittsburg, PA, USA) Impella® and BVS 5000® (both Abiomed Inc., Danvers, MA, USA), CentriMag® and Thoratec percutaneous ventricular assist device (pVAD)® (both Thoratec Corporation, Pleasanton, CA, USA). A specific emphasis will be made to describe relevant mechanisms of action, standard placement strategies, hemodynamic effects, relevant contraindications and complications, and important daily management considerations. PMID:26793330
Adolescent Balloon Analog Risk Task and Behaviors that Influence Risk of Motor Vehicle Crash Injury
Vaca, Federico E.; Walthall, Jessica M.; Ryan, Sheryl; Moriarty-Daley, Alison; Riera, Antonio; Crowley, Michael J.; Mayes, Linda C.
2013-01-01
Risk-taking propensity is a pivotal facet of motor vehicle crash involvement and subsequent traumatic injury in adolescents. Clinical encounters are important opportunities to identify teens with high risk-taking propensity who may later experience serious injury. Our objective was to compare self-reports of health risk behavior with performance on the Balloon Analog Risk Task (BART), a validated metric of risk-taking propensity, in adolescents during a clinical encounter. 100 adolescent patients from a hospital emergency department and adolescent health clinic completed a computer-based survey of self-reported risk behaviors including substance use behaviors and behaviors that influence crash involvement. They then completed the BART, a validated laboratory-based risk task in which participants earn points by pumping up a computer-generated balloon with greater pumps leading to increased chance of balloon explosion. 20 trials were undertaken. Mean number of pumps on the BART showed a correlation of .243 (p=.015) with self-reported driver/passenger behaviors and attitudes towards driving that influence risk of crash injury. Regression analyses showed that self-reports of substance use and mean number of pumps on the BART uniquely predict self-reports of behaviors influencing the risk of crash injury. The BART is a promising correlate of real-world risk-taking behavior related to traffic safety. It remains a valid predictor of behaviors influencing risk of crash injury when using just 10 trials, suggesting its utility as a quick and effective screening measure for use in busy clinical environments. This tool may be an important link to prevention interventions for those most at-risk for future motor vehicle crash involvement and injury. PMID:24406948
Frontal theta accounts for individual differences in the cost of conflict on decision making.
Pinner, John F L; Cavanagh, James F
2017-10-01
Cognitive conflict is often experienced as a difficult, frustrating, and aversive state. Recent studies have indicated that conflict acts as an implicit cost during learning, valuation, and the instantiation of cognitive control. Here we investigated if an implicit manipulation of conflict also influences explicit decision making to risk. Participants were required to perform a Balloon Analogue Risk Task wherein the virtual balloon was inflated by performing a flankers task. By varying the percent of incongruent flanker trials between balloons, we hypothesized that participants would pump the balloon fewer times in conditions of higher conflict and that frontal midline theta would account for significant variance in this relationship. Across two studies, we demonstrate that conflict did not elicit reliable behavioral changes in this task across participants. However, individual differences in frontal theta power accounted for significant variance by predicting diminished balloon pumps. Thus, while conflict costs may act as investments to some individuals (invigorating behavior), it is aversive to others (diminishing behavior), and frontal midline theta power accounts for these varying behavioral tendencies between individuals. These findings demonstrate how frontal midline theta is not only a candidate mechanism for implementing cognitive control, but it is sensitive to the inherent costs therein. Copyright © 2017 Elsevier B.V. All rights reserved.
Fluid dynamics of heart assist device
NASA Technical Reports Server (NTRS)
Jones, R. T.
1976-01-01
Certain hemodynamic phenomena that arise in connection with the use of artificial blood pumping devices are reviewed. Among these are: (1) Flows produced by collapsing bulbs; (2) the impedance presented by the aorta; (3) limiting velocities and instability of flow in elastic vessels; (4) effectiveness of valveless arterio-arterial pumps, and (5) wave reflection phenomena and instabilities associated with the intra-aortic balloon pump.
Negi, Smita I; Sokolovic, Mladen; Koifman, Edward; Kiramijyan, Sarkis; Torguson, Rebecca; Lindsay, Joseph; Ben-Dor, Itsik; Suddath, William; Pichard, Augusto; Satler, Lowell; Waksman, Ron
2016-02-01
Refractory cardiogenic shock (RCS) in acute myocardial infarction (AMI) is associated with high rates of mortality. Smaller ventricular assist devices, such as the intraaortic balloon pump, provide limited support. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) offers more robust mechanical ventricular support, but is not widely utilized by interventional cardiologists. This study aimed to evaluate the patient characteristics and outcomes of VA-ECMO with RCS in the setting of AMI. A retrospective chart review of all VA-ECMO cannulations between 2009 and 2014 was performed, and patients with an indication of RCS in AMI were identified. A total of 15 patients underwent VA-ECMO placement for AMI with RCS. One-third of these patients presented with out-of-hospital cardiac arrest, and 60% had ST-elevation myocardial infarction. The Intraaortic balloon pump was placed in addition to VA-ECMO in 60% of patients. Median duration of VA-ECMO support was 45 hours. Successful wean off VA-ECMO was obtained in 50% of the patients, and vascular complications occurred in 53% of patients. The survival rate at discharge was 47%, and all survivors were alive at 30 days post discharge. VA-ECMO is infrequently used in patients for cardiopulmonary resuscitation in the AMI setting. When used judiciously, it has good clinical outcomes in this group of patients. However, use of VA-ECMO should be individualized based on vascular anatomy for best results. Close cooperation among interventional cardiologists, cardiovascular surgeons, cardiologists, cardiac intensivists, and perfusionists is essential for success of this therapy for RCS in AMI.
ERIC Educational Resources Information Center
Galus, Pamela
2002-01-01
Introduces a science demonstration that illustrates the effects of pressure and gravity on humans using a marshmallow man and a vacuum pump. Demonstrates the same concept with shaving cream, balloons, and boiling water without raising temperature. (YDS)
Hemodynamic Performance of a Novel Right Ventricular Assist Device (PERKAT).
Kretzschmar, Daniel; Schulze, P Christian; Ferrari, Markus W
Acute right ventricular failure (RVF) is an increasing clinical problem and a life-threatening condition. Right ventricular assist devices represent a reasonable treatment option for patients with refractory RVF. We here present a novel percutaneously implantable device for right ventricular support. The PERKAT device is based on a nitinol stent cage, which is covered with valve-carrying foils. A flexible outlet trunk with a pigtail tip is connected to the distal part. The device is driven by an intra-aortic balloon pump (IABP) drive unit, which inflates/deflates a standard IABP-balloon placed within the stent cage. In-vitro evaluation was done in a liquid bath containing water or blood analog. The PERKAT device was tested in different afterload settings using two different IABP-balloons and varying inflation/deflation rates. We detected flow rates ranging from 1.97 to 3.93 L/min depending on the afterload setting, inflation/deflation rate, balloon size, and the medium used. Flow rates between water and blood analog were nearly comparable, and in the higher inflation/deflation rate settings slightly higher with water. Based on this promising in vitro data, the innovative percutaneously implantable PERKAT device has a potential to become a therapeutic option for patients with RVF refractory to medical treatment.
Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N; Pijls, Nico H J; de Mol, Bas A; Rutten, Marcel C M
2011-09-01
The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was to evaluate the benefits of the 40 cc IABP and the Impella 2.5 LP operating at 47,000 rpm in vitro, and compare their circulatory support capabilities in terms of cardiac output, coronary flow, cardiac stroke work, and arterial blood pressure. Clinical scenarios of cardiogenic preshock and cardiogenic shock (CS), with blood pressure depression, lowered cardiac output, and constant heart rate of 80 bpm, were modeled in a model-controlled mock circulation, featuring a systemic, pulmonary, and coronary vascular bed. The ventricles, represented by servomotor-operated piston pumps, included the Frank-Starling mechanism. The systemic circulation was modeled with a flexible tube having close-to-human aortic dimensions and compliance properties. Proximally, it featured a branch mimicking the brachiocephalic arteries and a physiological correct coronary flow model. The rest of the systemic and pulmonary impedance was modeled by four-element Windkessel models. In this system, the enhancement of coronary flow and blood pressure was tested with both support systems under healthy and pathological conditions. Hemodynamic differences between the IABP and the Impella 2.5 LP were small. In our laboratory model, both systems approximately yielded a 10% cardiac output increase and a 10% coronary flow increase. However, since the Impella 2.5 LP provided significantly better left ventricular unloading, the circulatory support capabilities were slightly in favor of the Impella 2.5 LP. On the other hand, pulsatility was enhanced with the IABP and lowered with the Impella 2.5 LP. The support capabilities of both the IABP and the Impella 2.5 LP strongly depended on the simulated hemodynamic conditions. Maximum hemodynamic benefits were achieved when mechanical circulatory support was applied on a simulated scenario of deep CS. © 2011, Copyright Eindhoven University of Technology (TU/e). Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Lee, B M K; Ti, L K
2002-08-01
We report an unusual presentation of phaeochromocytoma in a young man with a painful, pulsatile abdominal mass and elevated blood pressures. This led to a delay in diagnosis and resulted in the administration of triggers of catecholamine release, possibly causing a catecholamine surge. This caused the development of catecholamine-induced cardiomyopathy and multiple organ failure, requiring inotropic and ventilatory support, intra-aortic balloon pump and dialysis. Fortunately, his condition reversed with supportive treatment and alpha-adrenergic blockade. This illustrates the importance of having a high index of suspicion of phaeochromocytoma, especially in young patients with elevated blood pressures.
Chang, Ching-I; Yan, Huey-Yeu; Sung, Wen-Hsu; Shen, Shu-Cheng; Chuang, Pao-Yu
2006-01-01
The purpose of this research was to develop a computer-aided instruction system for intra-aortic balloon pumping (IABP) skills in clinical nursing with virtual instrument (VI) concepts. Computer graphic technologies were incorporated to provide not only static clinical nursing education, but also the simulated function of operating an expensive medical instrument with VI techniques. The content of nursing knowledge was adapted from current well-accepted clinical training materials. The VI functions were developed using computer graphic technology with photos of real medical instruments taken by digital camera. We wish the system could provide beginners of nursing education important teaching assistance.
Hemodynamic and metabolic effects of para- versus intraaortic counterpulsatile circulation supports.
Lu, Pong-Jeu; Lin, Pao-Yen; Yang, Chi-Fu Jeffrey; Hung, Chun-Hao; Chan, Ming-Yao; Hsu, Tzu-Cheng
2011-01-01
Despite the success of intraaortic balloon counterpulsation, data on physiologic indices and optimal inflation/deflation timing control of chronic counterpulsation devices are unclear. This study explored the acute hemodynamic and metabolic efficacy of a novel 40-ml stroke volume paraaortic blood pump (PABP) versus a standard intraaortic balloon pump (IABP). Acute porcine model was used with eight pigs randomly divided into PABP (n = 4) and IABP (n = 4) groups. Hemodynamic and metabolic measurements were obtained with and without mechanical assistance. In one pig, the inflation/deflation control was adjusted to different settings, with corresponding performance indices measured. The PABP significantly improved classical counterpulsation indices (p ≤ 0.05) and achieved an average beneficial effect on these indices 1.5-3.5 times greater than that of the IABP. Classical metabolic indices (tension time index and endocardial viability ratio [EVR]), and indices new to chronic counterpulsation research (coronary perfusion, left ventricular stroke work (SW), and a newly derived EVR) were also used in assessment. Both IABP assistance and PABP assistance improved these physiologic indices, with a trend toward PABP superiority in reducing left ventricular SW (p = 0.08). An optimal PABP deflation timing occurs during systole (25 milliseconds after the R-wave) and can minimize coronary regurgitation.
Acute microflow changes after stop and restart of intra-aortic balloon pump in cardiogenic shock.
Jung, Christian; Rödiger, Christoph; Fritzenwanger, Michael; Schumm, Julia; Lauten, Alexander; Figulla, Hans R; Ferrari, Markus
2009-08-01
The intra-aortic balloon counter pulsation (IABP) is the most frequently used method of mechanical cardiac support in cardiogenic shock (CS). Microcirculatory impairment correlates with outcome in critically ill patients. We therefore investigated the acute influence of IABP therapy on sublingual microflow in patients with CS. Sidestream darkfield intravitalmicroscopy was used in 13 patients with severe CS. The sublingual microvascular bed (10-100 microm) was examined according to current guidelines. We measured microflow in means of microvascular flow index at baseline and after intentional stop of IABP support. A computerized model was used for blinded off-line analysis. Microflow in vessels 10-50 microm in diameter was improved during IABP support (P < 0.001). Norepinephrine had a negative effect on the response to IABP related microflow improvement. Cardiac Perfusion Index (product of Cardiac Power index and microflow) correlated best with blood lactate levels. It was the aim of this study to evaluate the acute influence of IABP therapy on microflow in vivo. In this setting we found that IABP therapy improves sublingual microflow. Future studies should investigate Cardiac Perfusion Index under such conditions with respect to clinical decision making.
Biglino, Giovanni; Kolyva, Christina; Khir, Ashraf W
2012-01-01
Despite decades of successful clinical use of the intra aortic balloon pump (IABP), certain aspects of its operation are not yet fully understood. This work aims to investigate in vitro the mechanism underlying balloon inflation and deflation with varying assisting frequency and operating angle with respect to the horizontal, by studying the corresponding pressure and wave energy changes. A mock circulatory system (MCS), with physiological distribution of peripheral resistance and compliance, presented a controllable test bed. We used Wave Intensity Analysis (WIA) to identify balloon-generated waves and quantify their energy. Conventional hemodynamic parameters were also calculated. Tests were repeated at varying operating angles (0°-45°), resembling the semi-recumbent position in the ICU, and at different assisting frequencies (1:1, 1:2, 1:3). Two balloons (25 cc and 40 cc in volume) were tested. The main waves associated with counterpulsation were identified as a backward compression wave associated with balloon inflation and a backward expansion wave associated with balloon deflation. Results showed that the IABP inflation and deflation benefits are reduced with increasing angle, in terms of the size of the inflation and deflation waves as well as in terms of diastolic pressure augmentation and end-diastolic pressure reduction. Both WIA findings and pressure parameters indicated 1:1 as the most effective mode of pumping. This study shows that, in vitro, a greater benefit of counterpulsation can be achieved in the horizontal position at 1:1 assisting frequency, with a good correlation between wave and pressure results.
Rihal, Charanjit S; Naidu, Srihari S; Givertz, Michael M; Szeto, Wilson Y; Burke, James A; Kapur, Navin K; Kern, Morton; Garratt, Kirk N; Goldstein, James A; Dimas, Vivian; Tu, Thomas
2015-05-19
Although historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella(®); left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability. This document reviews the physiologic impact on the circulation of these devices and their use in specific clinical situations. These situations include patients undergoing high-risk percutaneous coronary intervention, those presenting with cardiogenic shock, and acute decompensated heart failure. Specialized uses for right-sided support and in pediatric populations are discussed and the clinical utility of mechanical circulatory support devices is reviewed, as are the American College of Cardiology/American Heart Association clinical practice guidelines. Copyright © 2015 The Society for Cardiovascular Angiography and Interventions, The American College of Cardiology Foundation, The Heart Failure Society of America, and The Society for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Rihal, Charanjit S; Naidu, Srihari S; Givertz, Michael M; Szeto, Wilson Y; Burke, James A; Kapur, Navin K; Kern, Morton; Garratt, Kirk N; Goldstein, James A; Dimas, Vivian; Tu, Thomas
2015-06-01
Although historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella®; left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability. This document reviews the physiologic impact on the circulation of these devices and their use in specific clinical situations. These situations include patients undergoing high-risk percutaneous coronary intervention, those presenting with cardiogenic shock, and acute decompensated heart failure. Specialized uses for right-sided support and in pediatric populations are discussed and the clinical utility of mechanical circulatory support devices is reviewed, as are the American College of Cardiology/American Heart Association clinical practice guidelines. © 2015 by The Society for Cardiovascular Angiography and Interventions, The American College of Cardiology Foundation, The Heart Failure Society of America, and The Society for Thoracic Surgery.
Spiro, Jon; Venugopal, Vinod; Raja, Yogesh; Ludman, Peter F; Townend, Jonathan N; Doshi, Sagar N
2015-05-01
Assessment of the feasibility and outcomes of the 2.5 L and 3.8 L Impella cardiac pump in patients with severe aortic stenosis (AS) and left ventricular impairment undergoing percutaneous revascularization (PCI) with or without balloon aortic valvuloplasty (BAV). We reviewed the clinical and procedural findings from a consecutive series of unselected patients with severe AS who underwent PCI during Impella support. In addition, we describe novel "balloon-assist" techniques that allowed implantation of Impella into the left ventricle (LV) when initial unassisted attempts failed. Five patients with severe AS were identified (four males, age 78.2 years, aortic valve area (AVA) 0.6 cm(2) , left ventricular ejection fraction (LVEF) 24 ± 5%, mean Society of Thoracic Surgeons (STS) mortality 11% (range 3-17%)). The Impella catheter traversed the aortic valve (AV) unassisted in only one patient, with four cases requiring balloon-assist techniques. All patients underwent planned revascularisation; mean procedure time 177 min (range 135-252 min), mean number of stents 3.4 (range 1-8), with three patients requiring rotational atherectomy. All procedures were well tolerated, with absence of arrhythmia, hypotension, pulmonary edema, stroke, or myocardial infarction. One patient died 48 hr post-PCI of multi-organ failure. The four remaining patients were well at 30 days. Implantation of the 2.5 and 3.8 L Impella appears feasible in patients with severe AS and left ventricle (LV) impairment. A balloon-assist technique may be used to facilitate device implantation when initial unassisted attempts fail. Improved hemodynamic stability may enhance the tolerability of lengthy and complex procedures. © 2014 Wiley Periodicals, Inc.
Humphreys, Kathryn L; Telzer, Eva H; Flannery, Jessica; Goff, Bonnie; Gabard-Durnam, Laurel; Gee, Dylan G; Lee, Steve S; Tottenham, Nim
2016-02-01
Decision making in the context of risk is a complex and dynamic process that changes across development. Here, we assessed the influence of sensitivity to negative feedback (e.g., loss) and learning on age-related changes in risky decision making, both of which show unique developmental trajectories. In the present study, we examined risky decision making in 216 individuals, ranging in age from 3-26 years, using the balloon emotional learning task (BELT), a computerized task in which participants pump up a series of virtual balloons to earn points, but risk balloon explosion on each trial, which results in no points. It is important to note that there were 3 balloon conditions, signified by different balloon colors, ranging from quick- to slow-to-explode, and participants could learn the color-condition pairings through task experience. Overall, we found age-related increases in pumps made and points earned. However, in the quick-to-explode condition, there was a nonlinear adolescent peak for points earned. Follow-up analyses indicated that this adolescent phenotype occurred at the developmental intersection of linear age-related increases in learning and decreases in sensitivity to negative feedback. Adolescence was marked by intermediate values on both these processes. These findings show that a combination of linearly changing processes can result in nonlinear changes in risky decision making, the adolescent-specific nature of which is associated with developmental improvements in learning and reduced sensitivity to negative feedback. (c) 2016 APA, all rights reserved).
Jacob, Samuel; Patel, Mitesh J; Lima, Brian; Felius, Joost; Malyala, Rajasekhar S; Chamogeorgakis, Themistokles; MacHannaford, Juan C; Gonzalez-Stawinski, Gonzalo V; Rafael, Aldo E
2016-07-01
Rupture of the ventricular septum during acute myocardial infarction usually occurs within the first week. The event is usually followed by low cardiac output, heart failure, and multiorgan failure. Despite the many advances in the nonoperative treatment of heart failure and cardiogenic shock, including the intra-aortic balloon pump and a multitude of new inotropic agents and vasodilators, these do not supplant the need for operative intervention in these critically ill patients. This article describes the successful use of extracorporeal membrane oxygenation support as a bridge to recovery postoperatively in a patient with a large infarct-produced ventricular septal defect.
Jacob, Samuel; Patel, Mitesh J.; Lima, Brian; Felius, Joost; Malyala, Rajasekhar S.; Chamogeorgakis, Themistokles; MacHannaford, Juan C.; Gonzalez-Stawinski, Gonzalo V.
2016-01-01
Rupture of the ventricular septum during acute myocardial infarction usually occurs within the first week. The event is usually followed by low cardiac output, heart failure, and multiorgan failure. Despite the many advances in the nonoperative treatment of heart failure and cardiogenic shock, including the intra-aortic balloon pump and a multitude of new inotropic agents and vasodilators, these do not supplant the need for operative intervention in these critically ill patients. This article describes the successful use of extracorporeal membrane oxygenation support as a bridge to recovery postoperatively in a patient with a large infarct-produced ventricular septal defect. PMID:27365878
Spine immobilization apparatus
NASA Technical Reports Server (NTRS)
Lambson, K. H.; Vykukal, H. C. (Inventor)
1981-01-01
The apparatus makes use of a normally flat, flexible bladder filled with beads or micro-balloons that form a rigid mass when the pressure within the bladder is decreased below ambient through the use of a suction pump so that the bladder can be conformed to the torso of the victim and provide the desired restraint. The bladder is strapped to the victim prior to being rigidified by an arrangement of straps which avoid the stomach area. The bladder is adapted to be secured to a rigid support, i.e., a rescue chair, so as to enable removal of a victim after the bladder has been made rigid. A double sealing connector is used to connect the bladder to the suction pump and a control valve is employed to vary the pressure within the bladder so as to soften and harden the bladder as desired.
Acconcia, M C; Caretta, Q; Romeo, F; Borzi, M; Perrone, M A; Sergi, D; Chiarotti, F; Calabrese, C M; Sili Scavalli, A; Gaudio, C
2018-04-01
Intra-aortic balloon pump (IABP) is the device most commonly investigated in patients with cardiogenic shock (CS) complicating acute myocardial infarction (AMI). Recently meta-analyses on this topic showed opposite results: some complied with the actual guideline recommendations, while others did not, due to the presence of bias. We investigated the reasons for the discrepancy among meta-analyses and strategies employed to avoid the potential source of bias. Scientific databases were searched for meta-analyses of IABP support in AMI complicated by CS. The presence of clinical diversity, methodological diversity and statistical heterogeneity were analyzed. When we found clinical or methodological diversity, we reanalyzed the data by comparing the patients selected for homogeneous groups. When the fixed effect model was employed despite the presence of statistical heterogeneity, the meta-analysis was repeated adopting the random effect model, with the same estimator used in the original meta-analysis. Twelve meta-analysis were selected. Six meta-analyses of randomized controlled trials (RCTs) were inconclusive because underpowered to detect the IABP effect. Five included RCTs and observational studies (Obs) and one only Obs. Some meta-analyses on RCTs and Obs had biased results due to presence of clinical and/or methodological diversity. The reanalysis of data reallocated for homogeneous groups was no more in contrast with guidelines recommendations. Meta-analyses performed without controlling for clinical and/or methodological diversity, represent a confounding message against a good clinical practice. The reanalysis of data demonstrates the validity of the current guidelines recommendations in addressing clinical decision making in providing IABP support in AMI complicated by CS.
Paton, Maria; Ashton, Lisa; Pearson, Ian; Sivananthan, Mohan
2015-01-01
Background A high number of patients do not survive primary percutaneous coronary intervention (PCI) complicated by cardiogenic shock (CS), even when assisted with intra-aortic balloon pump (IABP) counterpulsation. There is no accepted consensus on who may most benefit from IABP counterpulsation, although previous retrospective studies have reported predictors of survival for patients undergoing PCI and cardiac surgery. To date, a risk model for emergency primary PCI patients has not been ascertained. The objective of this study was to identify independent predictors for in-hospital survival, to create a standardized risk model to predict patients who may require IABP insertion during primary PCI. Method Retrospective data were from 165 patients who had undergone primary PCI with IABP due to CS complicating acute myocardial infarction (AMI), from September 2007 to 2010, and underwent logistic regression analysis, to evaluate the incremental risk factors associated with survival. Results The overall in-hospital mortality was 32.1% (53 patients). The incremental independent predictors for in-hospital survival were: patient age of less than 60 years (OR: 0.303, 95% CI: 0.11 - 0.83, P < 0.02) and the use of IABP support alone, as opposed to in adjunction with inotropic support (OR: 3.177, 95% CI: 1.159 - 8.708, P < 0.025). Conclusion This study illustrated an age of less than 60 years, and the use of IABP alone, to be independent predictors of in-hospital survival in patients with CS complicating AMI who undergo primary PCI assisted by IABP. No specific risk model could be determined. PMID:28197255
Paton, Maria; Ashton, Lisa; Pearson, Ian; Sivananthan, Mohan
2015-12-01
A high number of patients do not survive primary percutaneous coronary intervention (PCI) complicated by cardiogenic shock (CS), even when assisted with intra-aortic balloon pump (IABP) counterpulsation. There is no accepted consensus on who may most benefit from IABP counterpulsation, although previous retrospective studies have reported predictors of survival for patients undergoing PCI and cardiac surgery. To date, a risk model for emergency primary PCI patients has not been ascertained. The objective of this study was to identify independent predictors for in-hospital survival, to create a standardized risk model to predict patients who may require IABP insertion during primary PCI. Retrospective data were from 165 patients who had undergone primary PCI with IABP due to CS complicating acute myocardial infarction (AMI), from September 2007 to 2010, and underwent logistic regression analysis, to evaluate the incremental risk factors associated with survival. The overall in-hospital mortality was 32.1% (53 patients). The incremental independent predictors for in-hospital survival were: patient age of less than 60 years (OR: 0.303, 95% CI: 0.11 - 0.83, P < 0.02) and the use of IABP support alone, as opposed to in adjunction with inotropic support (OR: 3.177, 95% CI: 1.159 - 8.708, P < 0.025). This study illustrated an age of less than 60 years, and the use of IABP alone, to be independent predictors of in-hospital survival in patients with CS complicating AMI who undergo primary PCI assisted by IABP. No specific risk model could be determined.
Lim, Ki Moo; Lee, Jeong Sang; Gyeong, Min-Soo; Choi, Jae-Sung; Choi, Seong Wook
2013-01-01
To quantify the reduction in workload during intra-aortic balloon pump (IABP) therapy, indirect parameters are used, such as the mean arterial pressure during diastole, product of heart rate and peak systolic pressure, and pressure-volume area. Therefore, we investigated the cardiac energy consumption during IABP therapy using a cardiac electromechanics model. We incorporated an IABP function into a previously developed electromechanical model of the ventricle with a lumped model of the circulatory system and investigated the cardiac energy consumption at different IABP inflation volumes. When the IABP was used at inflation level 5, the cardiac output and stroke volume increased 11%, the ejection fraction increased 21%, the stroke work decreased 1%, the mean arterial pressure increased 10%, and the ATP consumption decreased 12%. These results show that although the ATP consumption is decreased significantly, stroke work is decreased only slightly, which indicates that the IABP helps the failed ventricle to pump blood efficiently. PMID:23341718
Lim, Ki Moo; Lee, Jeong Sang; Gyeong, Min-Soo; Choi, Jae-Sung; Choi, Seong Wook; Shim, Eun Bo
2013-01-01
To quantify the reduction in workload during intra-aortic balloon pump (IABP) therapy, indirect parameters are used, such as the mean arterial pressure during diastole, product of heart rate and peak systolic pressure, and pressure-volume area. Therefore, we investigated the cardiac energy consumption during IABP therapy using a cardiac electromechanics model. We incorporated an IABP function into a previously developed electromechanical model of the ventricle with a lumped model of the circulatory system and investigated the cardiac energy consumption at different IABP inflation volumes. When the IABP was used at inflation level 5, the cardiac output and stroke volume increased 11%, the ejection fraction increased 21%, the stroke work decreased 1%, the mean arterial pressure increased 10%, and the ATP consumption decreased 12%. These results show that although the ATP consumption is decreased significantly, stroke work is decreased only slightly, which indicates that the IABP helps the failed ventricle to pump blood efficiently.
Hadadzadeh, Mehdi; Hosseini, Seyed Habib; Mostafavi Pour Manshadi, Seyed Mohammad Yousof; Naderi, Nafiseh; Emami Meybodi, Mahmood
2013-01-01
Myocardial dysfunction is a major complication in cardiac surgery that needs inotropic support. This study evaluates the effect of milrinone on patients with low ventricular ejection fraction undergoing off- pump coronary artery bypass graft (OPCAB). The present study is designed to evaluate the effect of milrinone on myocardial dysfunction. Eighty patients with low ventricular ejection fraction (<35%), candidate for elective OPCAB, were enrolled in this study. They were randomly assigned to two groups. One group received milrinone (50 μg/kg) intravenously and another group received a saline as placebo followed by 24 hours infusion of each agent (0.5 μg/kg/min). Short outcome of patients such as hemodynamic parameters and left ventricular ejection fraction were variables evaluated. Serum levels of creatine phosphokinase, the MB isoenzyme of creatine kinase, occurrence of arrhythmias and mean duration of mechanical ventilation were significantly lower in milrinone group (P<0.05). The mean post operative left ventricular ejection fraction was significantly higher in milrinone group (P=0.031). There were no statistical significant differences between the two groups in terms of intra-aortic balloon pump, inotropic support requirement, myocardial ischemia, myocardial infarction, duration of inotropic support, duration of intensive care unit stay, mortality and morbidity rate. Administration of milrinone in patients undergoing OPCAB with low ventricular ejection fraction is useful and effective.
Effects of intraaortic balloon augmentation in a porcine model of endotoxemic shock.
Engoren, Milo; Habib, Robert H
2004-03-01
Patients with septic shock commonly have myocardial dysfunction associated with lactic acid production and troponin I release. The purpose of this study was to evaluate the effects on intraaortic balloon pump (IABP) support on myocardial dysfunction. Prospective, randomized controlled study. Animal research laboratory. Ten pigs had arterial, pulmonary arterial, and coronary catheters inserted. After receiving endotoxin infusion over 30 min, half the animals received IABP support. Coronary sinus lactic acid levels (P< 0.05 for both 90 min versus baseline and 60 min versus baseline) and arterial lactic acid levels (P < 0.05 for both 90 min versus baseline and 60 min versus baseline) increased with time but did not differ between IABP and sham groups. While overall there was no difference with time in myocardial lactic acid consumption or production (calculated as arterial lactic acid level minus coronary sinus lactic acid level), the IABP group showed net myocardial lactic acid consumption at 90 min, while the sham group showed myocardial lactic acid production. Three of five animals in each group showed troponin I release. The levels were similar and did not differ between groups. IABP had no benefits in this porcine model of endotoxemic shock.
Ten years single-centre experience with intra-aortic balloon pump.
Vandenplas, Guy; Bové, Thierry; Caes, Frank; Van Belleghem, Yves; François, Katrien; De Somer, Filip; Taeymans, Yves; Van Nooten, Guido
2011-12-01
The objective of this study was to investigate the patient characteristics and outcomes in 1406 patients undergoing intra-aortic balloon pump (IABP) counterpulsation. Between 1998 and 2008, 1406 consecutive patients were recorded in a prospective database. Based on the main clinical indication for IABP use, we defined 3 groups: group A, 630 cases of coronary ischaemia or infarction without serious left ventricular (LV) dysfunction; group B, 466 patients with left ventricular failure or cardiogenic shock; group C, 310 patients where IABP was used for miscellaneous procedures such as weaning from cardiopulmonary bypass or during high-risk angioplasty or surgery. Global mortality was 28% (n = 390), with a significant difference between group A (15%, n = 95) and group B (41%, n = 191) (P < 0.001). Mortality in group C was 34% (n = 104). Most insertions were done in the catheterization laboratory (n = 943) with subsequent mortality of 23% whereas 199 balloons were inserted in the operation room with 34% mortality. 170 balloons inserted in the intensive care unit resulted in 46% mortality (P < 0.001). Major IABP-induced complications were 6.8% with no statistical differences between the three groups. Advanced age, left ventricular failure and low BMI were identified as prognostic risk factors for early mortality. IABP deployed at an early clinical stage yields the best results, especially for acute coronary patients with preserved LV function whereas LV failure and late insertion result in worse outcome.
Ntalianis, Argyrios; Kapelios, Chris J; Kanakakis, John; Repasos, Evangelos; Pantsios, Christos; Nana, Emmeleia; Kontogiannis, Christos; Malliaras, Konstantinos; Tsamatsoulis, Michael; Kaldara, Elisabeth; Charitos, Christos; Nanas, John N
2015-08-01
Right ventricular dysfunction is associated with high morbidity and mortality in candidates for left ventricular assist device (LVAD) implantation or cardiac transplantation. We examined the effects of prolonged intra-aortic balloon pump (IABP) support on right ventricular, renal and hepatic functions in patients presenting with end-stage heart failure. Between March 2008 and June 2013, fifteen patients (mean age = 49.5 years; 14 men) with end-stage systolic heart failure (HF), contraindications for any life saving procedure (conventional cardiac surgery, heart transplantation, LVAD implantation) and right ventricular dysfunction were supported with the IABP. The patients remained on IABP support for a mean of 73 ± 50 days (median 72, range of 13-155). We measured the echocardiographic and hemodynamic changes in right ventricular function, and the changes in serum creatinine and bilirubin concentrations before and during IABP support. Mean right atrial pressure decreased from 12.7 ± 6.5 to 3.8 ± 3.3 (P < 0.001) and pulmonary artery pressure decreased from 35.7 ± 10.6 to 25 ± 8.4 mmHg (P = 0.001), while cardiac index increased from 1.5 ± 0.4 to 2.2 ± 0.7 l/m(2)/min (P = 0.003) and right ventricular stroke work index from 485 ± 228 to 688 ± 237 mmHg × ml/m(2) (P = 0.043). Right ventricular end-diastolic diameter decreased from 34.0 ± 6.5 mm to 27.8 ± 6.2 mm (P < 0.001) and tricuspid annular systolic tissue Doppler velocity increased from 9.6 ± 2.4 cm/s to 11.1 ± 2.3 cm/s (P = 0.029). Serum creatinine and bilirubin decreased from 2.1 ± 1.3 to 1.4 ± 0.6 mg/dl and 2.0 ± 1.0 to 0.9 ± 0.5 mg/dl, respectively (P = 0.002 and P < 0.001, respectively). Prolonged IABP support of patients presenting with end-stage heart failure and right ventricular dysfunction induced significant improvement in right ventricular and peripheral organ function. Copyright © 2015. Published by Elsevier Ireland Ltd.
The Balloon-Based Manometry Evaluation of Swallowing in Patients with Amyotrophic Lateral Sclerosis
Tomik, Jerzy; Tomik, Barbara; Gajec, Sebastian; Ceranowicz, Piotr; Pihut, Małgorzata; Olszanecki, Rafał; Stręk, Paweł; Składzień, Jacek
2017-01-01
The aim of the study was to analyse the disturbances of the oro-pharyngeal swallowing phase of dysphagia in amyotrophic lateral sclerosis (ALS) patients with the use of specific manometric measurements and to evaluate their plausible association with the duration of the disease. Seventeen patients with ALS were evaluated with manometric examinations of the oral and pharyngeal part of the gastrointestinal tract. Tests were carried out by using the oesophageal balloon-based method with four balloon transducers located 5 cm away from each other. The following manometric parameters were analysed: the base of tongue contraction (BTC) and the upper oesophageal sphincter pressure (UESP), and the hypopharyngeal suction pump (HSP) as well as the oro-pharyngeal, pharyngeal and hypopharyngeal transit time and average pharyngeal bolus velocity (oropharyngeal transit time (OTT), pharyngeal transit time (PTT), hypopharyngeal transit time (HTT) and average pharyngeal bolus velocity (APBV), respectively). Manomatric examinations during swallowing in patients with ALS showed significant weakness of BTC, a decrease of HSP and a decrease of the velocity of bolus transit inside the pharynx which were particularly marked between the first and the third examination. Manometric examinations of the oro-pharyngeal part of the gastrointestinal tract are useful and supportive methods in the analysis of swallowing disturbances in ALS patients. PMID:28346382
Goldstein, James A; Dixon, Simon R; Douglas, Pamela S; Ohman, E Magnus; Moses, Jeffrey; Popma, Jeffrey J; O'Neill, William W
2017-10-08
The Impella 2.5 axial flow pump, which is positioned across the aortic valve, is widely employed for hemodynamic support. The present study compared structural and functional integrity of the left heart valves in patients undergoing Impella vs intra-aortic balloon pump in the randomized PROTECT II trial. Transthoracic echocardiograms were performed at baseline, 1 and 3 months in 445 patients in the PROTECT II trial. Serial studies were analyzed by an independent echocardiography core laboratory for aortic and mitral valve structure and function, and left ventricular ejection fraction (LVEF). During Impella support there was no appreciable change in the degree of baseline valvular regurgitation. There were no cases of structural derangement of the mitral or aortic valve after use of the Impella device. At 90-day follow-up, there was an average 22% relative increase in LVEF from baseline (27% ± 9 vs. 33% ± 11, P < 0.001). The present echocardiographic analysis of the PROTECT II study confirms prior observations regarding the safety of the Impella 2.5 device with respect to mitral and aortic valve function. © 2017 Wiley Periodicals, Inc.
Hemodynamic energy generated by a combined centrifugal pump with an intra-aortic balloon pump.
Lim, Choon Hak; Son, Ho Sung; Fang, Yung Hu; Lee, Jung Joo; Baik, Kwang Je; Kim, Kyung Hyun; Kim, Bum Soo; Lee, Hye Won; Sun, Kyung
2006-01-01
We examined the pulsatility generated by an intra-aortic balloon pump/centrifugal pump (IABP/CP) combination in terms of energy equivalent pressure (EEP) and surplus hemodynamic energy (SHE). In five cardiac-arrested pigs, the outflow cannula of the CP was inserted into the ascending aorta, the inflow cannula in the right atrium. A 30-ml IABP was subsequently placed in the descending aorta. Extracorporeal circulation was maintained for 30 minutes using a pump flow of 75 ml/kg per minute by CP alone or by IABP/CP with pressure and flow measured in the right internal carotid artery. The IABP/CP combination converted the flow to pulsatile and increased pulse pressure significantly from 9.1 +/- 1.3 mm Hg to 54.9 +/- 6.1 mm Hg (p = 0.012). It also significantly increased the percent change from mean arterial pressure to EEP from 0.2 +/- 0.3% to 23.3 +/- 6.1% (p = 0.012) and SHE from 133.2 +/- 234.5 erg/cm to 20,219.8 +/- 5842.7 erg/cm3 (p = 0.012). However, no statistical difference was observed between CP and IABP/CP in terms of mean carotid artery pressure (p = NS). In a cardiac-arrested animal model, pulsatility generated by a IABP/CP combination may be effective in terms of energy equivalent pressure and surplus hemodynamic energy.
Deppe, Antje-Christin; Weber, Carolyn; Liakopoulos, Oliver J; Zeriouh, Mohamed; Slottosch, Ingo; Scherner, Maximilian; Kuhn, Elmar W; Choi, Yeong-Hoon; Wahlers, Thorsten
2017-03-01
Prophylactic intra-aortic balloon pump (IABP) support for high-risk patients before coronary artery bypass grafting (CABG) is controversial. This meta-analysis sought to determine the current role of preoperative IABP support. We performed a meta-analysis of randomized (RCT) and observational trials (OT) that fulfilled the following criteria: (1) Group comparison of patients with prophylactic IABP implantation before CABG with a control group; (2) reporting at least one desired clinical endpoint, including all-cause mortality, myocardial infarction, cerebrovascular accident (CVA), and renal failure. Pooled treatment effects (odds ratio [OR] or weighted mean difference, and 95% confidence intervals [95%CI]) were assessed using a fixed or random effects model. A total of 9,212 patients from 23 studies (7 RCT, 16 OT) were identified after a literature search of major databases using a predefined keyword list. Absolute risk reduction for mortality in RCTs was 4.4% (OR 0.43; 95%CI 0.25-0.73; p = 0.0025). Prophylactic IABP use before CABG surgery also decreased the risk for myocardial infarction (OR 0.58; 95%CI 0.43-0.78; p = 0.004), CVA (OR 0.67; 95%CI 0.47-0.97; p = 0.042), and renal failure (OR 0.62; 95%CI 0.47-0.83; p = 0.0014). Length of intensive care unit stay (p < 0.0001) and length of hospital stay (p < 0.0001) were significantly reduced in patients with preoperative IABP use. Current evidence from RCT and OT suggests beneficial effects for the IABP in high-risk patients before CABG surgery. © 2017 Wiley Periodicals, Inc.
Curtis, Jeptha P; Rathore, Saif S; Wang, Yongfei; Chen, Jersey; Nallamothu, Brahmajee K; Krumholz, Harlan M
2012-01-01
Intra-aortic balloon pumps (IABP) frequently are used to provide hemodynamic support during high risk percutaneous coronary intervention (PCI), but clinical evidence to support their use is mixed. We examined hospital variation in IABP use among high risk PCI patients, and determined the association of IABP use on mortality in this population. We analyzed data submitted to the CathPCI Registry between January 2005 and December 2007. High risk PCI was defined as having at least 1 of the following features: unprotected left main artery as the target vessel, cardiogenic shock, severely depressed left ventricular function, or ST segment elevation myocardial infarction. Hospitals were categorized into quartiles by their proportional use of IABP. We examined differences in in-hospital mortality across hospital quartiles using a hierarchical logistic regression model to adjust for differences in patient and hospital characteristics across hospital quartiles of IABP use. IABPs were used in 18,990 (10.5%) of 181,599 high risk PCIs. Proportional use of IABP varied significantly across hospital quartiles: Q1, 0.0 to 6.5%; Q2, 6.6 to 9.2%; Q3, 9.3 to 14.1%; Q4, 14.2 to 40.0%. In multivariable analysis, after adjustment for differences in patient and hospital characteristics, in-hospital mortality was comparable across quartiles of hospital IABP usage (Q1, Ref; Q2, odds ratio 1.11, 95% CI 0.99-1.24; Q3, OR 1.03, 95% CI 0.92-1.15; Q4, OR 1.06, 95% CI 0.94-1.18). IABP use varied significantly across hospitals for high risk PCI. However, this variation in IABP use was not associated with differences in in-hospital mortality.
Pierrakos, Charalampos N; Bonios, Michael J; Drakos, Stavros G; Charitos, Efstratios I; Tsolakis, Elias J; Ntalianis, Argirios; Nanas, Serafim N; Charitos, Christos E; Nanas, John N; Terrovitis, John V
2011-09-01
The effects of the intra-aortic balloon pump (IABP) counterpulsation on the extent of myocardial infarction (MI), the no-reflow phenomenon (NRP), and coronary blood flow (CBF) during reperfusion in an ischemia-reperfusion experimental model have not been clarified. Eleven pigs underwent occlusion of the mid left anterior descending coronary artery for 1 h, followed by reperfusion for 2 h. CBF, distal to the occlusion site, was measured. In six experiments, IABP support began 10 min before, and continued throughout reperfusion (IABP Group). Five pigs without IABP support served as controls. At the end of each experiment, the myocardial area at risk (MAR) of infarction and the extent of MI and NRP were measured. Hemodynamic measurements at baseline and during coronary occlusion were similar in both groups. During reperfusion, systolic aortic blood pressure was significantly lower in the IABP Group than in controls. In the IABP Group, CBF reached a peak at 5 min of reperfusion, gradually decreased, but remained higher than at baseline, and significantly higher than in controls throughout the 2 h of reperfusion. In controls, CBF increased significantly above baseline immediately after the onset of reperfusion, then returned to baseline within 90 min. The extent of NRP (37 ± 25% vs. 68 ± 17%, P = 0.047) and MI (39 ± 23% vs. 67 ± 13%, P = 0.036), both expressed as percentage of MAR, was significantly less in the IABP group than in controls. After prolonged myocardial ischemia, IABP assistance started just 10 min before and throughout reperfusion increased CBF and limited infarct size and extent of NRP. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
A new noninvasive controlled intra-articular ankle distraction technique on a cadaver model.
Aydin, Ahmet T; Ozcanli, Haluk; Soyuncu, Yetkin; Dabak, Tayyar K
2006-08-01
Effective joint distraction is crucial in arthroscopic ankle surgery. We describe an effective and controlled intra-articular ankle distraction technique that we have studied by means of a fresh-frozen cadaver model. Using a kyphoplasty balloon, which is currently used in spine surgery, we tried to achieve a controlled distraction. After the fixation of the cadaver model, standard anteromedial and anterolateral portals were used for ankle arthroscopy. From the same portals, the kyphoplasty balloon was inserted and placed in an appropriate position intra-articularly. The necessary amount of distraction was achieved by inflating the kyphoplasty balloon with a pressure regulation pump. All anatomic sites of the ankle joint were easily visualized with the arthroscope during surgery by changing the pressure and the intra-articular position of the kyphoplasty balloon. Ankle distraction was clearly seen on the arthroscopic and image intensifier view. The kyphoplasty balloon is simple to place through the standard portals and the advantage is that it allows easy manipulation of the arthroscopic instruments from the same portal.
Fresiello, Libera; Khir, Ashraf William; Di Molfetta, Arianna; Kozarski, Maciej; Ferrari, Gianfranco
2013-03-01
Despite 50 years of research to assess the intra-aortic balloon pump (IABP) effects on patients' hemodynamics, some issues related to the effects of this therapy are still not fully understood. One of these issues is the effect of IABP, its inflation timing and duration on peripheral circulation autonomic controls. This work provides a systematic analysis of IABP effects on baroreflex using a cardiovascular hybrid model, which consists of computational and hydraulic submodels. The work also included a baroreflex computational model that was connected to a hydraulic model with a 40-cm(3) balloon. The IABP was operated at different inflation trigger timings (-0.14 to 0.31 s) and inflation durations (0.05-0.45 s), with time of the dicrotic notch being taken as t = 0. Baroreflex-dependent parameters-afferent and efferent pathway activity, heart rate, peripheral resistance, and venous tone-were evaluated at each of the inflation trigger times and durations considered. Balloon early inflation (0.09 s before the dicrotic notch) with inflation duration of 0.25 s generated a maximum net increment of afferent pathway activity of 10%, thus leading to a decrement of efferent sympathetic activity by 15.3% compared with baseline values. These times also resulted in a reduction in peripheral resistance and heart rate by 4 and 4.3% compared with baseline value. We conclude that optimum IABP triggering time results in positive effects on peripheral circulation autonomic controls. Conversely, if the balloon is not properly timed, peripheral resistance and heart rate may even increase, which could lead to detrimental outcomes. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Phaeochromocytoma [corrected] crisis.
Whitelaw, B C; Prague, J K; Mustafa, O G; Schulte, K-M; Hopkins, P A; Gilbert, J A; McGregor, A M; Aylwin, S J B
2014-01-01
Phaeochromocytoma [corrected] crisis is an endocrine emergency associated with significant mortality. There is little published guidance on the management of phaeochromocytoma [corrected] crisis. This clinical practice update summarizes the relevant published literature, including a detailed review of cases published in the past 5 years, and a proposed classification system. We review the recommended management of phaeochromocytoma [corrected] crisis including the use of alpha-blockade, which is strongly associated with survival of a crisis. Mechanical circulatory supportive therapy (including intra-aortic balloon pump or extra-corporeal membrane oxygenation) is strongly recommended for patients with sustained hypotension. Surgical intervention should be deferred until medical stabilization is achieved. © 2013 John Wiley & Sons Ltd.
Effects of atmospheric pressure conditions on flow rate of an elastomeric infusion pump.
Wang, Jong; Moeller, Anna; Ding, Yuanpang Samuel
2012-04-01
The effects of pressure conditions, both hyperbaric and hypobaric, on the flow rate of an elastomeric infusion pump were investigated. The altered pressure conditions were tested with the restrictor outlet at two different conditions: (1) at the same pressure condition as the Infusor elastomeric balloon and (2) with the outlet exposed to ambient conditions. Five different pressure conditions were tested. These included ambient pressure (98-101 kilopascals [kPa]) and test pressures controlled to be 10 or 20 kPa below or 75 or 150 kPa above the ambient pressure. A theoretical calculation based on the principles of fluid mechanics was also used to predict the pump's flow rate at various ambient conditions. The conditions in which the Infusor elastomeric pump and restrictor outlet were at the same pressure gave rise to average flow rates within the ±10% tolerance of the calculated target flow rate of 11 mL/hr. The flow rate of the Infusor pump decreased when the pressure conditions changed from hypobaric to ambient. The flow rate increased when the pressure conditions changed from hyperbaric to ambient. The flow rate of the Infusor elastomeric pump was not affected when the balloon reservoir and restrictor outlet were at the same pressure. The flow rate varied from 58.54% to 377.04% of the labeled flow rate when the pressure applied to the reservoir varied from 20 kPa below to 150 kPa above the pressure applied to the restrictor outlet, respectively. The maximum difference between observed flow rates and those calculated by applying fluid mechanics was 4.9%.
2014-01-01
Background The addition of an intra-aortic balloon pump (IABP) during peripheral venoarterial extracorporeal membrane oxygenation (VA ECMO) support has been shown to improve coronary bypass graft flows and cardiac function in refractory cardiogenic shock after cardiac surgery. The purpose of this study was to evaluate the impact of additional IABP support on the cerebral blood flow (CBF) in patients with peripheral VA ECMO following cardiac procedures. Methods Twelve patients (mean age 60.40 ± 9.80 years) received VA ECMO combined with IABP support for postcardiotomy cardiogenic shock after coronary artery bypass grafting. The mean CBF in the bilateral middle cerebral arteries was measured with and without IABP counterpulsation by transcranial Doppler. The patients provided their control values. The mean CBF data were divided into two groups (pulsatile pressure greater than 10 mmHg, P group; pulsatile pressure less than 10 mmHg, N group) based on whether the patients experienced cardiac stun. The mean cerebral blood flow in VA ECMO (IABP turned off) alone and VA ECMO with IABP support were compared using the paired t test. Results All of the patients were successfully weaned from VA ECMO, and eight patients survived to discharge. The addition of IABP to VA ECMO did not change the mean CBF (251.47 ± 79.28 ml/min vs. 251.30 ± 79.47 ml/min, P = 0.96). The mean CBF was higher in VA ECMO alone than in VA ECMO combined with IABP support in the N group (257.68 ± 97.21 ml/min vs. 239.47 ± 95.60, P = 0.00). The addition of IABP to VA ECMO support increased the mean CBF values significantly compared with VA ECMO alone (261.68 ± 82.45 ml/min vs. 244.43 ± 45.85 ml/min, P = 0.00) in the P group. Conclusion These results demonstrate that an IABP significantly changes the CBF during peripheral VA ECMO, depending on the antegrade blood flow by spontaneous cardiac function. The addition of an IABP to VA ECMO support decreased the CBF during cardiac stun, and it increased CBF without cardiac stun. PMID:24766774
PERKAT RV: first in vivo data of a novel right heart assist device.
Kretzschmar, Daniel; Lauten, Alexander; Schubert, Harald; Bischoff, Sabine; Schulze, Christian; Ferrari, Markus W
2018-04-06
Mechanical right ventricular (RV) support offers a treatment option for critically ill patients with RV failure (RVF). We developed an assist device for rapid percutaneous implantation. The aim of the present study was to investigate the implantation procedure, haemodynamic performance and possible side effects of the novel right ventricular assist device - PERKAT RV - in an animal model. The PERkutane KATheterpumptechnologie RV (PERKAT RV) device consists of a nitinol chamber covered by foil containing inflow valves. An outlet tube is attached to its distal part. The system is designed for 18 Fr percutaneous implantation. The chamber is unfolded in the inferior vena cava while the outlet tube bypasses the right heart with the tip in the pulmonary trunk. An IABP balloon is placed inside. Balloon deflation generates blood flow into the chamber; during inflation, blood is guided into the pulmonary arteries. Acute RVF was induced by venous injection of Sephadex in seven sheep for evaluation of the device. The PERKAT RV was able to improve haemodynamics immediately generating a median increase in cardiac output of 59%. Longer pump support was evaluated in a second study. Four sheep were supported for eight hours without any problems. The percutaneous implantation and explantation of the PERKAT RV device was possible in the designed way. The sheep studies proved beneficial haemodynamic effects in acute RVF. The system offers easy and safe treatment in acute RVF.
NASA Astrophysics Data System (ADS)
Buduru, Suneel Kumar
2016-07-01
The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) is a unique center of expertise working throughout the year to design, fabricate and launch scientific balloons mainly for space astronomy, atmospheric science and engineering experiments. Recently TIFR-BF extended its support to new user scientists for conducting balloon launches for biological and middle atmospheric sciences. For the first time two balloon launches conducted for sending live lab rats to upper stratosphere and provided launch support for different balloon campaigns such as Tropical Tropopause Dynamics (TTD) to study water vapour content in upper tropospheric and lower stratospheric regions over Hyderabad and the other balloon campaign to study the Asian Tropopause Aerosol Layer (BATAL) during the Indian summer monsoon season. BATAL is the first campaign to conduct balloon launches during active (South-West) monsoon season using zero pressure balloons of different volumes. TIFR-BF also provided zero pressure and sounding balloon support to various research institutes and organizations in India and for several international space projects. In this paper, we present details on our increased capability of balloon fabrication for carrying heavier payloads, development of high strength balloon load tapes and recent developments of flight control and safety systems. A summary of the various flights conducted in two years will be presented along with the future ballooning plans.
Scientific Balloons for Venus Exploration
NASA Astrophysics Data System (ADS)
Cutts, James; Yavrouian, Andre; Nott, Julian; Baines, Kevin; Limaye, Sanjay; Wilson, Colin; Kerzhanovich, Viktor; Voss, Paul; Hall, Jeffery
Almost 30 years ago, two balloons were successfully deployed into the atmosphere of Venus as an element of the VeGa - Venus Halley mission conducted by the Soviet Union. As interest in further Venus exploration grows among the established planetary exploration agencies - in Europe, Japan, Russia and the United States, use of balloons is emerging as an essential part of that investigative program. Venus balloons have been proposed in NASA’s Discovery program and ESA’s cosmic vision program and are a key element in NASA’s strategic plan for Venus exploration. At JPL, the focus for the last decade has been on the development of a 7m diameter superpressure pressure(twice that of VeGa) capable of carrying a 100 kg payload (14 times that of VeGA balloons), operating for more than 30 days (15 times the 2 day flight duration of the VeGa balloons) and transmitting up to 20 Mbit of data (300 times that of VeGa balloons). This new generation of balloons must tolerate day night transitions on Venus as well as extended exposure to the sulfuric acid environment. These constant altitude balloons operating at an altitude of about 55 km on Venus where temperatures are benign can also deploy sondes to sound the atmosphere beneath the probe and deliver deep sondes equipped to survive and operate down to the surface. The technology for these balloons is now maturing rapidly and we are now looking forward to the prospects for altitude control balloons that can cycle repeatedly through the Venus cloud region. One concept, which has been used for tropospheric profiling in Antarctica, is the pumped-helium balloon, with heritage to the anchor balloon, and would be best adapted for flight above the 55 km level. Phase change balloons, which use the atmosphere as a heat engine, can be used to investigate the lower cloud region down to 30 km. Progress in components for high temperature operation may also enable investigation of the deep atmosphere of Venus with metal-based balloons.
Continuous internal counterpulsation as a bridge to recovery in acute and chronic heart failure
Kontogiannis, Christos D; Malliaras, Konstantinos; Kapelios, Chris J; Mason, Jay W; Nanas, John N
2016-01-01
Cardiac recovery from cardiogenic shock (CS) and end-stage chronic heart failure (HF) remains an often insurmountable therapeutic challenge. The counterpulsation technique exerts numerous beneficial effects on systemic hemodynamics and left ventricular mechanoenergetics, rendering it attractive for promoting myocardial recovery in both acute and chronic HF. Although a recent clinical trial has questioned the clinical effectiveness of short-term hemodynamic support with intra-aortic balloon pump (IABP, the main representative of the counterpulsation technique) in CS complicating myocardial infarction, the issue remains open to further investigation. Moreover, preliminary data suggest that long-term IABP support in patients with end-stage HF is safe and may mediate recovery of left- or/and right-sided cardiac function, facilitating long-term weaning from mechanical support or enabling the application of other permanent, life-saving solutions. The potential of long-term counterpulsation could possibly be enhanced by implementation of novel, fully implantable counterpulsation devices. PMID:27011909
Cardiac Transplantation in a Jehovah's Witness
Lammermeier, David E.; Duncan, J. Michael; Kuykendall, R. Craig; Macris, Michael P.; Frazier, O. Howard
1988-01-01
Between July 1982 and October 1987, surgeons at our institution performed 215 cardiac transplantation procedures, 1 of which was in a 46-year-old Jehovah's Witness with congestive cardiomyopathy, who required preoperative intra-aortic balloon pump support. At surgery, the cardiopulmonary bypass system was primed with 1600 ml of Ringer's lactate solution and dextrose. In the 57 minutes during which the patient was on cardiopulmonary bypass, the intra-aortic balloon was removed and successful orthotopic heart transplantation was performed. No supplemental blood or blood product was used, either during or after the procedure. The estimated intraoperative blood loss was 300 ml, and the postoperative chest tube drainage amounted to 1495 ml. Postoperative hematologic abnormalities (mild hypoprothrombinemia, mild thrombocytopenia, mild platelet dysfunction, and moderate hypochromic microcytic anemia) were corrected with Imferon, vitamin K, and desmopressin acetate administered intravenously, and with ferrous sulfate administered orally. This case, which to our knowledge is only the 2nd cardiac transplant in a Jehovah's Witness, further establishes that these patients can undergo even the most major of open-heart procedures without supplemental blood. (Texas Heart Institute Journal 1988;15:189-191) PMID:15227251
Bauer, Adrian; Schaarschmidt, Jan; Grosse, F Oliver; Al Alam, Nidal; Hausmann, Harald; Krämer, Klaus; Strüber, Martin; Mohr, Friedrich W
2014-06-01
The use of extracorporeal life support systems (ECLS) in patients with postcardiotomy low cardiac output syndrome (LCO) as a bridge to recovery and bridge to implantation of ventricular assist device (VAD) is common nowadays. A 59-year-old patient with acute myocardial infarction received a percutaneous transluminal angioplasty and stenting of the circumflex artery. During catheterization of the left coronary artery (LAD), the patient showed ventricular fibrillation and required defibrillation and cardiopulmonary resuscitation. After implantation of an intra-aortic balloon pump, the patient immediately was transmitted to the operating room. He received emergency coronary artery bypass grafting in a beating heart technique using pump-assisted minimal extracorporeal circulation circuit (MECC). Two bypass grafts were performed to the LAD and the right posterior descending artery. Despite initial successful weaning off cardiopulmonary bypass with high-dose inotropic support, the patient presented postcardiotomy LCO and an ECLS was implanted. The primary setup of the heparin-coated MECC system was modified and used postoperatively. As a result of the absence of an in-house VAD program, the patient was switched to a transportable ECLS the next day and was transferred by helicopter to the nearest VAD center where the patient received a successful insertion of a left VAD 3 days later.
Scientific ballooning in India Recent developments
NASA Astrophysics Data System (ADS)
Manchanda, R. K.
Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.
Yang, Feng; Wang, Jinhong; Hou, Dengbang; Xing, Jialin; Liu, Feng; Xing, Zhi chen; Jiang, Chunjing; Hao, Xing; Du, Zhongtao; Yang, Xiaofang; Zhao, Yanyan; Miao, Na; Jiang, Yu; Dong, Ran; Gu, Chengxiong; Sun, Lizhong; Wang, Hong; Hou, Xiaotong
2016-01-01
Severe left ventricular (LV) dysfunction patients undergoing off-pump coronary artery bypass grafting (OPCAB) are often associated with a higher mortality. The efficacy and safety of the preoperative prophylactic intra-aortic balloon pump (IABP) insertion is not well established. 416 consecutive patients with severe LV dysfunction (ejection fraction ≤35%) undergoing isolated OPCAB were enrolled in a retrospective observational study. 191 patients was enrolled in the IABP group; the remaining 225 patients was in control group. A total of 129 pairs of patients were propensity-score matched. No significant differences in demographic and preoperative risk factors were found between the two groups. The postoperative 30-day mortality occurred more frequently in the control group compared with the IABP group (8.5% vs. 1.6%, p = 0.02). There was a significant reduction of low cardiac output syndrome in the IABP group compared with the control group (14% vs. 6.2%, p = 0.04). Prolonged mechanical ventilation (≥48 h) occurred more frequently in the control group (34.9% vs. 20.9%, p = 0.02). IABP also decreased the postoperative length of stay. Preoperative IABP was associated with a lower 30-day mortality, suggesting that it is effective in patients with severe LV dysfunction undergoing OPCAB. PMID:27279591
Scientific Ballooning in India - Recent Developments
NASA Astrophysics Data System (ADS)
Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.
Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.
Air Force Cambridge Research Laboratories balloon operations
NASA Technical Reports Server (NTRS)
Danaher, T. J.
1974-01-01
The establishment and functions of the AFCRL balloon operations facility are discussed. The types of research work conducted by the facility are defined. The facilities which support the balloon programs are described. The free balloon and tethered balloon capabilities are analyzed.
Kolyva, Christina; Biglino, Giovanni; Pepper, John R; Khir, Ashraf W
2012-03-01
A mock circulatory system (MCS) was designed to replicate a physiological environment for in vitro testing and was assessed with the intra-aortic balloon pump (IABP). The MCS was comprised of an artificial left ventricle (LV), connected to a 14-branch polyurethane-compound aortic model. Physiological distribution of terminal resistance and compliance according to published data was implemented with capillary tubes of different sizes and syringes of varying air volume, respectively, fitted at the outlets of the branches. The ends of the aortic branches were connected to a common tube representing the venous system and an overhead reservoir provided atrial pressure. An IABP operating a 40-cc balloon was set to counterpulsate with the LV. Total arterial compliance of the system was 0.94 mL/mm Hg and total arterial resistance was 20.3 ± 3.3 mm Hg/L/min. At control, physiological flow distribution was achieved and both mean and phasic aortic pressure and flow were physiological. With the IABP, aortic pressure exhibited the major features of counterpulsation: diastolic augmentation during inflation, inflection point at onset of deflation, and end-diastolic reduction at the end of deflation. The contribution of balloon inflation and deflation was also evident on the aortic flow pattern. This MCS was verified to be suitable for IABP testing and with further adaptations it could be used for studying other hemodynamic problems and ventricular assist devices. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
The National Scientific Balloon Facility. [balloon launching capabilities of ground facility
NASA Technical Reports Server (NTRS)
Kubara, R. S.
1974-01-01
The establishment and operation of the National Scientific Balloon Facility are discussed. The balloon launching capabilities are described. The ground support systems, communication facilities, and meteorological services are analyzed.
Review of aeromedical intra-aortic balloon pump retrieval in New South Wales.
Burns, Brian; Reid, Cliff; Habig, Karel
2013-02-01
The intra-aortic balloon pump (IABP) was first introduced in 1968 to augment cardiac output in the haemodynamically unstable patient and serve as a bridge to treatment options such as coronary artery bypass grafting and cardiac transplantation. Transfer of IABP-dependent patients for upgrade of clinical care is increasingly common and safe. In Australia, percutaneous coronary intervention centres can be located outside cardiothoracic surgical centres. This study reviews IABP medical retrieval by a doctor/paramedic team after implementation of a standardized protocol. This was a retrospective case series review, using descriptive statistics. Greater Sydney Area Helicopter Emergency Service carried out 22 cases from 1 May 2007 to 31 December 2009. Median age was 62 years [interquartile range (IQR) 51-83], 67% were male. In all, 63% of patients were retrieved on inotropic support, 29% overall received invasive ventilation. Highest frequency indications were myocardial infarction, cardiogenic shock and bridge to coronary artery bypass grafts. There were complications during 18% of all retrievals and no adverse outcomes. Of the patients, 67% (14/21) were retrieved by road and 33% (7/21) by helicopter (longest distance 500 km). Median stabilization time by a retrieval team was 1 h 15 min (IQR 50 min to 3 h 30 min). Median mission time was 4 h 55 min (IQR 3 h 50 min to 8 h 54 min). Our system offers a safe method of IABP medical retrieval. The doctor and paramedic combination complements strengths in logistics and critical care. This serves as a guide to other systems looking to put in place a similar model of care.
Dyub, Adel M; Whitlock, Richard P; Abouzahr, Labib L; Cinà, Claudio S
2008-01-01
To assess the effectiveness of preoperative intra-aortic balloon pump (IABP) placement in high-risk patients undergoing coronary bypass surgery (CABG). The primary outcome was hospital mortality and secondary outcomes were IABP-related complications (bleeding, leg ischemia, aortic dissection). MEDLINE, EMBASE, Cochrane registry of Controlled Trials, and reference lists of relevant articles were searched. We included randomized controlled trials (RCTs), and cohort studies that fulfilled our a priori inclusion criteria. Eligibility decisions, relevance, study validity, and data extraction were performed in duplicate using pre-specified criteria. Meta-analysis was conducted using a random effects model. Ten publications fulfilled our eligibility criteria, of which four were RCTs and six were cohort studies with controls. There were statistical as well as clinical heterogeneity among included studies. A total of 1034 patients received preoperative IABP and 1329 did not receive preoperative IABP. The pooled odds ratio (OR) for hospital mortality in patients treated with preoperative IABP was 0.41 (95% CI, 0.21-0.82, p = 0.01). The number needed to treat was 17. The pooled OR for hospital mortality from randomized trials was 0.18 (95% CI, 0.06-0.57, p = 0.003) and from cohort studies was 0.54 (95% CI, 0.24-1.2, p = 0.13). Overall, 3.7% (13 of 349) of patients who received preoperative IABP developed either limb ischemia or haematoma at the IABP insertion site, and most of these complications improved after discontinuation of IABP. Evidence from this meta-analysis support the use of preoperative IABP in high-risk patients to reduce hospital mortality.
Greater Risk-Sensitivity of Dorsolateral Prefrontal Cortex in Young Smokers than in Nonsmokers
Galván, Adriana; Schonberg, Tom; Mumford, Jeanette; Kohno, Milky; Poldrack, Russell A.; London, Edythe D.
2013-01-01
Rationale Despite a national reduction in the prevalence of cigarette smoking, ~19% of the adult U.S. population persists in this behavior, with the highest prevalence among 18–25-year-olds. Given that the choice to smoke imposes a known health risk, clarification of brain function related to decision-making, particularly involving risk-taking, in smokers may inform prevention and smoking cessation strategies. Objectives This study aimed to compare brain function related to decision-making in young smokers and nonsmokers. Methods The Balloon Analogue Risk Task (BART) is a computerized risky decision-making task in which participants pump virtual balloons, each pump associated with an incremental increase in potential payoff on a given trial but also with greater risk of balloon explosion and loss of payoff. We used this task to compare brain activation associated with risky decision-making in smokers (n=18) and nonsmokers (n=25) while they performed the BART during functional magnetic resonance imaging (fMRI). The participants were young men and women, 17–21 years of age. Results Risk level (number of pumps) modulated brain activation in the right dorsolateral and ventrolateral prefrontal cortices more in smokers than in nonsmokers; and smoking severity (Heaviness of Smoking Index) was positively related to this modulation in an adjacent frontal region. Conclusions Given evidence for involvement of the right dorsolateral and ventrolateral prefrontal cortices in inhibitory control, these findings suggest that young smokers have a different contribution of prefrontal cortical substrates to risky decision-making than nonsmokers. Future studies are warranted to determine whether the observed neurobiological differences precede or result from smoking. PMID:23644912
Introduction (Special Issue on Scientific Balloon Capabilities and Instrumentation)
NASA Technical Reports Server (NTRS)
Gaskin, Jessica A.; Smith, I. S.; Jones, W. V.
2014-01-01
In 1783, the Montgolfier brothers ushered in a new era of transportation and exploration when they used hot air to drive an un-tethered balloon to an altitude of 2 km. Made of sackcloth and held together with cords, this balloon challenged the way we thought about human travel, and it has since evolved into a robust platform for performing novel science and testing new technologies. Today, high-altitude balloons regularly reach altitudes of 40 km, and they can support payloads that weigh more than 3,000 kg. Long-duration balloons can currently support mission durations lasting 55 days, and developing balloon technologies (i.e. Super-Pressure Balloons) are expected to extend that duration to 100 days or longer; competing with satellite payloads. This relatively inexpensive platform supports a broad range of science payloads, spanning multiple disciplines (astrophysics, heliophysics, planetary and earth science.) Applications extending beyond traditional science include testing new technologies for eventual space-based application and stratospheric airships for planetary applications.
Nwaejike, Nnamdi; Son, Andre Y; Milano, Carmelo A; Daneshmand, Mani A
2017-10-01
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: Is there a role for upper-extremity intra-aortic balloon pump counterpulsation (UE-IABP) in the treatment of end-stage heart failure? Altogether 230 papers were found using the reported search, of which 6 papers represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Of the 163 bridge-to-transplantation (BTT) patients, 141 (86.5%) were successfully transplanted and of the 9 bridge-to-recovery (BTR) patients, 6 (66.7%) were successfully weaned from the device. Length of support ranged from 3 to 152 days, and the most frequent complications were device malfunction or migration necessitating exchange or repositioning, occurring at a collective rate of 37.3%. UE-IABP is a minimally invasive and cost-effective strategy that provides haemodynamic support while preserving both the mediastinum and the functional status in BTR and BTT patients who may not tolerate more invasive modes of mechanical circulatory support. We conclude that UE-IABP can be used as a bridge-to-recovery (BTR) or transplant (BTT) in patients with end-stage heart failure. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Venezky, Dina; Wessells, Stephen
2010-01-01
A caldera is a large, usually circular volcanic depression formed when magma is withdrawn or erupted from a shallow underground magma reservoir. It is often difficult to visualize how calderas form. This simple experiment using flour, a balloon, tubing, and a bicycle pump, provides a helpful visualization for caldera formation.
NASA Astrophysics Data System (ADS)
Gaskin, J. A.; Smith, I. S.; Jones, W. V.
In 1783, the Montgolfier brothers ushered in a new era of transportation and exploration when they used hot air to drive an un-tethered balloon to an altitude of 2 km. Made of sackcloth and held together with cords, this balloon challenged the way we thought about human travel, and it has since evolved into a robust platform for performing novel science and testing new technologies. Today, high-altitude balloons regularly reach altitudes of 40 km, and they can support payloads that weigh more than 3000 kg. Long-duration balloons can currently support mission durations lasting 55 days, and developing balloon technologies (i.e. Super-Pressure Balloons) are expected to extend that duration to 100 days or longer; competing with satellite payloads. This relatively inexpensive platform supports a broad range of science payloads, spanning multiple disciplines (astrophysics, heliophysics, planetary and earth science). Applications extending beyond traditional science include testing new technologies for eventual space-based application and stratospheric airships for planetary applications.
Zhang, Jie-Min; Liu, Xiao-Cheng; Liu, Zhi-Gang; Zhao, Long; Yang, Li; Liu, Tian-Wen; He, Guo-Wei
2015-11-24
Previously designed intra-thoracic paraaortic counterpulsation device has limited stroke volume and may depress the lung to cause complications. The purpose of this study was to evaluate the hemodynamic effects of an extra-thoracic paraaortic counterpulsation device (ETPACD) in comparison to intraaortic balloon pump (IABP) in an animal model with acute heart failure. The acute heart failure model was successfully induced by snaring branch of anterior descending coronary artery in sheep (weighting, 38-50 kg, n = 8). The ETPACD is a single port, 65-ml stroke volume blood chamber designed to be connected to descending aorta through a valveless graft and placed extra-thorax. In comparison, a standard clinical 40-ml IABP was placed in the descending aorta. The hemodynamic indices of both devices were recorded during counterpulsation assistance. Two of the sheep were allowed to survive for 1 week to examine the prolonged effect. Both ETPACD and IABP increased cardiac output with higher effect of ETPACD (13.52 % vs. 8.19 % in IABP, P < 0.05) and on mean diastolic aortic pressure (26.73 % vs. 12.58 % in IABP, P < 0.01). Both ETPACD and IABP also produced a greater reduction in left ventricular end-diastolic pressure (26.77 % vs. 23.08 %, P > 0.05). The ETPACD increased left carotid artery flow more significantly the IABP (18.00 % vs. 9.19 % , P < 0.05). In two of the sheep allowed to survive for 1 week, the device worked well with no complications and there was no thrombus formation in the chamber of ETPACD. This study demonstrated that both ETPACD and IABP provided benefit of circulatory support in acute heart failure with better effect on hemodynamic parameters provided by ETPACD. Therefore, ETPACD with theoretical larger stroke volume may become a promising counterpulsation device for treatment of heart failure.
Fried, Justin A; Nair, Abhinav; Takeda, Koji; Clerkin, Kevin; Topkara, Veli K; Masoumi, Amirali; Yuzefpolskaya, Melana; Takayama, Hiroo; Naka, Yoshifumi; Burkhoff, Daniel; Kirtane, Ajay; Dimitrios Karmpaliotis, S M; Moses, Jeffrey; Colombo, Paolo C; Garan, A Reshad
2018-03-20
The role of the intra-aortic balloon pump (IABP) in acute decompensated heart failure (HF) with cardiogenic shock (CS) is largely undefined. In this study we sought to assess the hemodynamic and clinical response to IABP in chronic HF patients with CS and identify predictors of response to this device. We retrospectively reviewed all patients undergoing IABP implantation from 2011 to 2016 at our institution to identify chronic HF patients with acute decompensation and CS (cardiac index <2.2 liters/min/m 2 and systolic blood pressure <90 mm Hg or need for vasoactive medications to maintain this level). Clinical deterioration on IABP was defined as failure to bridge to either discharge on medical therapy or durable heart replacement therapy (HRT; durable left ventricular assist device or heart transplant) with IABP alone. We identified 132 chronic HF patients with IABP placed after decompensation with hemodynamic evidence of CS. Overall 30-day survival was 84.1%, and 78.0% of patients were successfully bridged to HRT or discharge without need for escalation of device support. The complication rate during IABP support was 2.3%. Multivariable analysis identified ischemic cardiomyopathy (odds ratio [OR] 3.24, 95% confidence interval [CI] 1.16 to 9.06; p = 0.03) and pulmonary artery pulsatility index (PAPi) <2.0 (OR 5.04, 95% CI 1.86 to 13.63; p = 0.001) as predictors of clinical deterioration on IABP. Overall outcomes with IABP in acute decompensated chronic HF patients are encouraging, and IABP is a reasonable first-line device for chronic HF patients with CS. Baseline right ventricular function, as measured by PAPi, is a major predictor of outcomes with IABP in this population. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
An Overview of the NASA Sounding Rocket and Balloon Programs
NASA Technical Reports Server (NTRS)
Eberspeaker, Philip J.; Smith, Ira S.
2003-01-01
The U.S. National Aeronautics and Space Administration (NASA) Sounding Rockets and Balloon Programs conduct a total of 50 to 60 missions per year in support of the NASA scientific community. These missions support investigations sponsored by NASA's Offices of Space Science, Life and Microgravity Sciences & Applications, and Earth Science. The Goddard Space Flight Center has management and implementation responsibility for these programs. The NASA Sounding Rockets Program provides the science community with payload development support, environmental testing, launch vehicles, and launch operations from fixed and mobile launch ranges. Sounding rockets continue to provide a cost-effective way to make in situ observations from 50 to 1500 km in the near-earth environment and to uniquely cover the altitude regime between 50 km and 130 km above the Earth's surface. New technology efforts include GPS payload event triggering, tailored trajectories, new vehicle configuration development to expand current capabilities, and the feasibility assessment of an ultra high altitude sounding rocket vehicle. The NASA Balloon Program continues to make advancements and developments in its capabilities for support of the scientific ballooning community. The Long Duration Balloon (LDB) is capable of providing flight durations in excess of two weeks and has had many successful flights since its development. The NASA Balloon Program is currently engaged in the development of the Ultra Long Duration Balloon (ULDB), which will be capable of providing flight times up to 100-days. Additional development efforts are focusing on ultra high altitude balloons, station keeping techniques and planetary balloon technologies.
Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads
NASA Technical Reports Server (NTRS)
Kogut, Alan; James, Bryan; Fixsen, Dale
2013-01-01
Astrophysical observations at millimeter wavelengths require large (2-to-5- meter diameter) telescopes carried to altitudes above 35 km by scientific research balloons. The scientific performance is greatly enhanced if the telescope is cooled to temperatures below 10 K with no emissive windows between the telescope and the sky. Standard liquid helium bucket dewars can contain a suitable telescope for telescope diameter less than two meters. However, the mass of a dewar large enough to hold a 3-to-5-meter diameter telescope would exceed the balloon lift capacity. The solution is to separate the functions of cryogen storage and in-flight thermal isolation, utilizing the unique physical conditions at balloon altitudes. Conventional dewars are launched cold: the vacuum walls necessary for thermal isolation must also withstand the pressure gradient at sea level and are correspondingly thick and heavy. The pressure at 40 km is less than 0.3% of sea level: a dewar designed for use only at 40 km can use ultra thin walls to achieve significant reductions in mass. This innovation concerns new construction and operational techniques to produce a lightweight liquid helium bucket dewar. The dewar is intended for use on high-altitude balloon payloads. The mass is low enough to allow a large (3-to-5-meter) diameter dewar to fly at altitudes above 35 km on conventional scientific research balloons without exceeding the lift capability of the balloon. The lightweight dewar has thin (250- micron) stainless steel walls. The walls are too thin to support the pressure gradient at sea level: the dewar launches warm with the vacuum space vented continuously during ascent to eliminate any pressure gradient across the walls. A commercial 500-liter storage dewar maintains a reservoir of liquid helium within a minimal (hence low mass) volume. Once a 40-km altitude is reached, the valve venting the vacuum space of the bucket dewar is closed to seal the vacuum space. A vacuum pump then evacuates the dewar vacuum space to provide the necessary thermal isolation. Liquid helium may then be transferred from the storage dewar into the bucket dewar to cool the telescope inside the bucket dewar. By splitting the functions of helium storage and in-flight thermal isolation, the parasitic mass associated with the dewar pressure vessel is eliminated to achieve factor-of-five or better reduction in mass. The lower mass allows flight on conventional scientific research balloons, even for telescopes 3 to 5 meters in diameter.
An Overview of the NASA Sounding Rockets and Balloon Programs
NASA Technical Reports Server (NTRS)
Flowers, Bobby J.; Needleman, Harvey C.
1999-01-01
The U.S. National Aeronautics and Space Administration (NASA) Sounding Rockets and Balloon Programs conduct a combined total of approximately fifty to sixty missions per year in support of the NASA scientific community. These missions are provided in support of investigations sponsored by NASA'S Offices of Space Science, Life and Microgravity Sciences & Applications, and Earth Science. The Goddard Space Flight Center has management and implementation responsibility for these programs. The NASA Sounding Rockets Program has continued to su,pport the science community by integrating their experiments into the sounding rocket payload and providing the rocket vehicle and launch operations necessary to provide the altitude/time required obtain the science objectives. The sounding rockets continue to provide a cost-effective way to make in situ observations from 50 to 1500 km in the near-earth environment and to uniquely cover the altitude regime between 50 km and 130 km above the Earth's surface, which is physically inaccessible to either balloons or satellites. A new architecture for providing this support has been introduced this year with the establishment of the NASA Sounding Rockets Contract. The Program has continued to introduce improvements into their operations and ground and flight systems. An overview of the NASA Sounding Rockets Program with special emphasis on the new support contract will be presented. The NASA Balloon Program continues to make advancements and developments in its capabilities for support of the scientific ballooning community. Long duration balloon (LDB) is a prominent aspect of the program with two campaigns scheduled for this calendar year. Two flights are scheduled in the Northern Hemisphere from Fairbanks, Alaska, in June and two flights are scheduled from McMurdo, Antarctica, in the Southern Hemisphere in December. The comprehensive balloon research and development (R&D) effort has continued with advances being made across the spectrum of balloon related disciplines. As a result of these technology advancements a new ultra long duration balloon project (ULDB) for the development of a 100- day duration balloon capability has been initiated. The ULDB will rely upon new balloon materials and designs to accomplish its goals. The Program has also continued to introduce new technology and improvements into flights systems, ground systems and operational techniques. An overview of the various aspects of the NASA Balloon Program will be presented.
Terrovitis, John V; Charitos, Christos E; Tsolakis, Elias J; Dolou, Paraskevi; Pierrakos, Charalampos N; Siafakas, Kostas X; Nanas, John N
2003-12-01
The purpose of this study was to compare the hemodynamic effectiveness of a 30-ml stroke volume paraaortic counterpulsation device (PACD), presenting the advantages of ease of implantation and driving by a standard intraaortic balloon pump (IABP) console (Datascope 96, Datascope Corp., Montvale, NJ, USA) to that of a 40-ml IABP, in the setting of experimental heart failure. In an acute heart failure model, the IABP was placed in the descending aorta and the PACD in the ascending aorta of eight pigs. Both devices were driven by the same system, and hemodynamic measurements were obtained with and without mechanical assistance. The two pumps significantly reduced the systolic and end-diastolic aortic pressures, but the PACD reduced the latter more effectively (42.6 +/- 18.1% vs 11.0 +/- 9.9%, p = 0.0001). Both pumps provided significant aortic diastolic augmentation, but the counterpulsation wave of the PACD was significantly greater (augmentation of 44.8 +/- 22.2% vs 37.6 +/- 15.6%, p = 0.031). Both lowered the end-diastolic left ventricular pressure with a trend toward PACD superiority (24.2 +/- 13.7% vs 19.7 +/- 13.5%, p = 0.064). It is concluded that the PACD, even with smaller stroke volume, is more effective than the IABP. The simplicity of its implantation, together with the ability of the standard IABP consoles to control its function, make it a promising device for mechanical assistance of the failing heart.
In vitro evaluation of the effect of aortic compliance on pediatric intra-aortic balloon pumping.
Minich, L L; Tani, L Y; Hawkins, J A; Bartkowiak, R R; Royall, M L; Pantalos, G M
2001-04-01
OBJECTIVES: To evaluate the effect of aortic compliance on pediatric intra-aortic balloon pumping (IABP). DESIGN: In vitro study using a mechanical model of the pediatric left heart circulation. SETTING: Cardiovascular fluid dynamics research laboratory. SUBJECT: Pulsatile flow system simulating the pediatric left heart circulation and two different aortas with compliances comparable to those of the pediatric aorta (0.12 and 0.07 mL/mm Hg). INTERVENTIONS: Measurements were made at a baseline peak aortic flow of 4 L/min, at simulated shock (1.7 L/min), and with 1:1 IABP (rates, 130 and 150 bpm; balloon volumes, 2.5 and 5.0 mL). MEASUREMENTS AND MAIN RESULTS: Peak flow rates were measured in the ascending aorta, coronary arterial system, and brachiocephalic arterial systems. Aortic pressure was measured in the ascending aorta. For both aortas (0.12 and 0.07 mL/mm Hg), IABP resulted in diastolic augmentation (38 +/- 8 and 43 +/- 16 mm Hg) and afterload reduction (4 +/- 2 and 6 +/- 3 mm Hg). For both aortas, compared to shock, IABP resulted in significant increases in coronary arterial and brachiocephalic arterial flow and aortic pressure for both aortas. Aortic flow significantly increased only in the less-compliant aorta. CONCLUSIONS: In a laboratory model of pediatric left heart circulation, IABP results in diastolic augmentation, afterload reduction, and improved hemodynamics, even in aortas of greater compliance.
Calculating Payload for a Tethered Balloon System
Charles D. Tangren
1980-01-01
A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....
Therapy of stress (takotsubo) cardiomyopathy: present shortcomings and future perspectives.
Brunetti, Natale Daniele; Santoro, Francesco; De Gennaro, Luisa; Correale, Michele; Kentaro, Hayashi; Gaglione, Antonio; Di Biase, Matteo
2016-09-01
Several therapeutic options are available for the treatment of the acute phase of stress cardiomyopathy, pharmacological (β-blockers, diuretics, anticoagulants, antiarrhythmics, noncatecholamine inotropics [levosimendan]), and nonpharmacological (intra-aortic balloon pumping, extracorporeal membrane oxygenation), according to the wide possible clinical presentation and course of the disease. However, there is a gap in evidence, and very few data come from randomized and adequately powered studies. Some evidence supports the use of β-blockers, in particular with a short half-life, in the case of left ventricular outflow tract obstruction, and angiotensin-converting enzyme inhibitors in secondary prevention. Future perspectives include the study of genetic basis of stress cardiomyopathy, role of miRNA and neurovegetative modulation. Randomized studies, however, are surely warranted.
NASA Technical Reports Server (NTRS)
Stimpfle, R. M.; Anderson, J. G.
1988-01-01
Midday stratospheric OH density measurements have been carried out within the altitude interval of 31 to 24 km using the laser-induced fluorescence technique deployed on a balloon-borne gondola launched from Palestine, Texas on July 15, 1987. Laser output at 282 nm is produced with a pulsed, 17 kHz repetition rate, copper vapor laser pumped tunable dye laser. The OH mixing ratio ranged from 16 + or - 5 ppt at 31 km to 4 + or - 3 ppt in the 27 to 24 km region. Simultaneous ozone and water vapor measurements were also obtained with separate instruments.
den Uil, Corstiaan A; Lagrand, Wim K; van der Ent, Martin; Jewbali, Lucia S D; Brugts, Jasper J; Spronk, Peter E; Simoons, Maarten L
2009-01-01
It was the aim of this study to evaluate the effects of intra-aortic balloon pump (IABP) counterpulsation on sublingual microcirculation as a model for tissue perfusion. In 13 patients with cardiogenic shock treated with IABP, the IABP assist ratio was reduced from 1:1 to 1:8 for 15 min. Using sidestream dark field imaging, 117 movie files of the sublingual microcirculation were obtained and quantified at different IABP assist ratios at 3 time points: 1:1 (T0), 1:8 (T1) and 1:1 (T2), respectively. Data are presented as the median and interquartile range. The median age of the patients was 59 years (range 56-73), and 62% were males. Discontinuation of IABP decreased the mean arterial pressure [75 mm Hg (71-84) at T0 vs. 69 mm Hg (64-79) at T1; p < 0.001], cardiac index [2.9 l/min/m2 (1.6-3.3) at T0 vs. 2.4 l/min/m2 (1.5-2.8) at T1; p = 0.005] and cardiac power index [0.46 W/m2 (0.29-0.59) at T0 vs. 0.36 W/m2 (0.24-0.50) at T1; p = 0.006]. However, these modest changes in macrohemodynamics did not significantly influence sublingual perfused capillary density and capillary red blood cell velocity (p = 0.28 and 0.73, respectively). A temporary, modest decrease in microcirculatory driving force, induced by lowering the IABP assist ratio, does not impair sublingual microcirculatory perfusion as measured by a novel 2-dimensional imaging technique. Copyright 2009 S. Karger AG, Basel.
Sá, Michel Pompeu B O; Ferraz, Paulo E; Escobar, Rodrigo R; Martins, Wendell N; Nunes, Eliobas O; Vasconcelos, Frederico P; Lima, Ricardo C
2012-11-01
The aim of this study was to assess the efficacy of a prophylactic intra-aortic balloon pump (IABP) in high-risk patients undergoing coronary artery bypass graft surgery. MEDLINE, EMBASE, CENTRAL/CCTR, SciELO, LILACS, Google Scholar, and reference lists of relevant articles were searched. We included only randomized controlled trials. Assessments for eligibility, relevance, and study validity and data extraction were performed in duplicate using prespecified criteria. Meta-analysis was carried out using fixed-effect and random-effect models. Seven publications fulfilled our eligibility criteria. There was no important statistical heterogeneity or publication bias among included studies. In total, 177 patients received prophylactic IABP and 168 did not. Overall relative risk (RR) for hospital mortality in patients treated with prophylactic IABP was 0.255 [95% confidence interval (CI), 0.122-0.533; P<0.001; same results for both effect models]. Pooled RR for postoperative low cardiac output syndrome was 0.206 (95% CI, 0.109-0.389; P<0.001) for the fixed-effect model and 0.219 (95% CI, 0.095-0.504; P<0.001) for the random-effect model. Patients treated with prophylactic IABP presented an overall difference in means for length of intensive care unit stay and hospital stay, which was lower than that in the control group (P<0.001 for both effect models). Only 7.4% (13/177) of patients who received prophylactic IABP developed complications at an insertion site, with no IABP-related death. This meta-analysis supports the use of prophylactic IABP in high-risk patients to reduce hospital mortality. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.
Keller, Benjamin A; Salcedo, Edgardo S; Williams, Timothy K; Neff, Lucas P; Carden, Anthony J; Li, Yiran; Gotlib, Oren; Tran, Nam K; Galante, Joseph M
2016-09-01
Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an adjunct technique for salvaging patients with noncompressible torso hemorrhage. Current REBOA training paradigms require large animals, virtual reality simulators, or human cadavers for acquisition of skills. These training strategies are expensive and resource intensive, which may prevent widespread dissemination of REBOA. We have developed a low-cost, near-physiologic, pulsatile REBOA simulator by connecting an anatomic vascular circuit constructed out of latex and polyvinyl chloride tubing to a commercially available pump. This pulsatile simulator is capable of generating cardiac outputs ranging from 1.7 to 6.8 L/min with corresponding arterial blood pressures of 54 to 226/14 to 121 mmHg. The simulator accommodates a 12 French introducer sheath and a CODA balloon catheter. Upon balloon inflation, the arterial waveform distal to the occlusion flattens, distal pulsation within the simulator is lost, and systolic blood pressures proximal to the balloon catheter increase by up to 62 mmHg. Further development and validation of this simulator will allow for refinement, reduction, and replacement of large animal models, costly virtual reality simulators, and perfused cadavers for training purposes. This will ultimately facilitate the low-cost, high-fidelity REBOA simulation needed for the widespread dissemination of this life-saving technique.
NASA Technical Reports Server (NTRS)
Papen, George
1995-01-01
This proposal funded 100 high altitude weather balloons costing $15,500 to support the deployment of a Rayleigh/Raman/Na lidar at the South Pole. One year of measurements have been completed and it is estimated that the balloons will provide another 1-2 years of data.
Bloss, P; Werner, C
2000-06-01
We propose a simple model to describe pressure-time and pressure-volume curves for the free balloon (balloon in air) of balloon catheters, taking into account the dynamics of the inflation device. On the basis of our investigations of the flow rate-dependence of characteristic parameters of the pressure-time curves, the appropriateness of this simple model is demonstrated using a representative example. Basic considerations lead to the following assumptions: (1) the flow within the shaft of the catheter is laminar, and (ii) the volume decrease of the liquid used for inflation due to pressurization can be neglected if the liquid is carefully degassed prior to inflation, and if the total volume of the liquid in the system is less than 2 ml. Taking into account the dynamics of the inflation device used for pumping the liquid into the proximal end of the shaft during inflation, the inflation process can be subdivided into the following three phases: initial phase, filling phase and dilatation phase. For these three phases, the transformation of the time into the volume coordinates is given. On the basis of our model, the following parameters of the balloon catheter can be determined from a measured pressure-time curve: (1) the resistance to flow of the liquid through the shaft of the catheter and the resulting pressure drop across the shaft, (2) the residual volume and residual pressure of the balloon, and (3) the volume compliance of the balloon catheter with and without the inflation device.
Variation in hospital rates of intraaortic balloon pump use in coronary artery bypass operations.
Ghali, W A; Ash, A S; Hall, R E; Moskowitz, M A
1999-02-01
Little is known about regional patterns of intraaortic balloon pump (IABP) use in coronary artery bypass graft (CABG) operations. Our objectives were (1) to identify clinical variables associated with IABP use, and (2) to examine risk-adjusted rates of IABP use for 12 Massachusetts hospitals performing CABG operations. We used hospital discharge data to identify 6944 CABG surgical cases. Logistic regression was used to identify clinical variables associated with IABP use, and the resulting multivariate model was then used to risk adjust hospital rates of IABP use. The IABP was used in 13.4% of the CABG surgical cases. The clinical variables independently associated with IABP use were cardiogenic shock, same admission angioplasty, prior CABG operation, cardiac arrest, congestive heart failure, recent myocardial infarction, and urgent admission status. Risk-adjusted rates of IABP use varied widely across hospitals from 7.8% to 20.8% (p < 0.0001). Hospital rates of IABP use vary considerably in Massachusetts. This practice variation may be related to the persistent uncertainty regarding the precise clinical indications for the IABP in this patient population.
Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.
NASA Astrophysics Data System (ADS)
Vasudevan, Rajagopalan
2012-07-01
The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.
den Uil, Corstiaan A; Valk, Suzanne D A; Cheng, Jin M; Kappetein, Arie P; Bogers, Ad J J C; van Domburg, Ron T; Simoons, Maarten L
2009-08-01
The aim of this study was to evaluate short- and long-term outcome in patients undergoing coronary artery bypass grafting (CABG), who received an intra-aortic balloon pump (IABP) prior to surgery. Between January 1990 and June 2004, all patients (n=154) who received an IABP prior to on-pump CABG in our center were included. Patients received the IABP for vital indications (i.e. either unstable angina refractory to medical therapy or cardiogenic shock; group 1: n=99) or for prophylactic reasons (group 2: n=55). A Cox proportional hazards model was used to identify predictors of long-term all-cause mortality. Compared with the EuroSCORE predictive model, observed 30-day mortality in group 1 (15.2%) was slightly higher than predicted (10.3%). A decrease in 30-day mortality occurred in group 2 (median predicted mortality was 7.2% and observed was 0%). Cumulative 1-, 5-, and 6-year survival was 82.8+/-3.8%, 70.1+/-4.9%, and 67.3+/-5.1% for group 1 vs. 98.2+/-1.8%, 84.0+/-5.6% and 84.0+/-5.6% for group 2 (Log-rank: P=0.02). Logistic EuroSCORE (HR 1.03 [1.01-1.05], P=0.007) was an independent predictor of long-term all-cause mortality.
Kim, Myung Hwa; Shim, Yon Hee; Kim, Min-Soo; Shin, Yang-Sik; Lee, Hyun Joo; Lee, Jeong Soo
2017-01-01
When considering the principles of a pain control strategy by patients, reliable administration of additional bolus doses is important for providing the adequate analgesia and improving patient satisfaction. We compared the efficacy of elastomeric patient-control module (PCM) with conventional PCM providing epidural analgesia postoperatively.A noninferiority comparison was used. Eighty-six patients scheduled for open upper abdominal surgery were randomized to use either an elastomeric or conventional PCM connected to balloon pump. After successful epidural catheter insertion at T6-8 level, fentanyl (15-20 μg/kg) in 0.3% ropivacaine 100 mL was administered at basal rate 2 mL/h with bolus 2 mL and lock-out time 15 minutes. The primary outcome was the verbal numerical rating score for pain.The 95% confidence intervals for differences in pain scores during the first 48 hours postoperatively were <1, indicating noninferiority of the elastomeric PCM. The duration of pump reservoir exhaustion was shorter for the elastomeric PCM (mean [SD], 33 hours [8 hours] vs 40 hours [8 hours], P = 0.0003). There were no differences in the frequency of PCM use, additional analgesics, or adverse events between groups.The elastomeric PCM was as effective as conventional PCM with and exhibited a similar safety profile.
Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R.
2015-01-01
Abstract The intra‐aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre‐, intra‐, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi‐recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra‐aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. PMID:25959284
Levin, Ricardo; Degrange, Marcela; Del Mazo, Carlos; Tanus, Eduardo; Porcile, Rafael
2012-01-01
BACKGROUND: The calcium sensitizer levosimendan has been used in cardiac surgery for the treatment of postoperative low cardiac output syndrome (LCOS) and difficult weaning from cardiopulmonary bypass (CPB). OBJECTIVES: To evaluate the effects of preoperative treatment with levosimendan on 30-day mortality, the risk of developing LCOS and the requirement for inotropes, vasopressors and intra-aortic balloon pumps in patients with severe left ventricular dysfunction. METHODS: Patient with severe left ventricular dysfunction and an ejection fraction <25% undergoing coronary artery bypass grafting with CPB were admitted 24 h before surgery and were randomly assigned to receive levosimendan (loading dose 10 μg/kg followed by a 23 h continuous infusion of 0.1μg/kg/min) or a placebo. RESULTS: From December 1, 2002 to June 1, 2008, a total of 252 patients were enrolled (127 in the levosimendan group and 125 in the control group). Individuals treated with levosimendan exhibited a lower incidence of complicated weaning from CPB (2.4% versus 9.6%; P<0.05), decreased mortality (3.9% versus 12.8%; P<0.05) and a lower incidence of LCOS (7.1% versus 20.8%; P<0.05) compared with the control group. The levosimendan group also had a lower requirement for inotropes (7.9% versus 58.4%; P<0.05), vasopressors (14.2% versus 45.6%; P<0.05) and intra-aortic balloon pumps (6.3% versus 30.4%; P<0.05). CONCLUSION: Patients with severe left ventricle dysfunction (ejection fraction <25%) undergoing coronary artery bypass grafting with CPB who were pretreated with levosimendan exhibited lower mortality, a decreased risk for developing LCOS and a reduced requirement for inotropes, vasopressors and intra-aortic balloon pumps. Studies with a larger number of patients are required to confirm whether these findings represent a new strategy to reduce the operative risk in this high-risk patient population. PMID:23620700
NASA Astrophysics Data System (ADS)
Orr, Dwayne
CSBF Engineering Overview Dwayne Orr (Presenting Author) Columbia Scientific Balloon Facility, Palestine, Texas (USA) Dwayne.Orr@csbf.nasa.gov The Columbia Scientific Balloon Facility (CSBF) at Palestine, Texas provides operational and engineering support for the launch of NASA Scientific Balloons. Over the years with the support of the NASA Balloon Program Office, CSBF has developed unique flight systems with the focus of providing a highly reliable, cost effective medium for giving Scientist’s access to a near space environment. This paper will provide an overview of the CSBF flight systems with an emphasis on recent developments and plans for the future.
Gelsomino, Sandro; Renzulli, Attilio; Rubino, Antonino S; Romano, Salvatore Mario; Lucà, Fabiana; Valente, Serafina; Gensini, Gian Franco; Lorusso, Roberto
2012-08-01
The effects of operational modes of intra-aortic balloon pumping (IABP) on coronary haemodynamics and oxygen delivery/demand ratio are unknown and were investigated in an experimental model of myocardial ischaemia reperfusion. Healthy swine (n = 24) underwent 120-minute ligation of the left anterior descending coronary artery followed by 24 h of reperfusion and were randomly assigned to have IABP 1:1 (n = 6), IABP 1:2 (n = 6), IABP 1:3 (n = 6) in the descending aorta or to no IABP implantation (n = 6) 5 min after the onset of reperfusion. Systolic (CBF(Sys)) and diastolic (CBF(Dia)) coronary blood flow, systolic (CR(Sys)) and diastolic (CR(Dia)) coronary resistances and endocardial viability ratio (EVR), as an expression of the oxygen delivery/demand ratio, were measured at 30 min, 1, 6, 12 and 24 h after coronary reperfusion, respectively. IABP at the 1:1 operational mode significantly increased CBF(Dia) and EVR, and reduced CR(Dia) throughout the experiment. Contrastingly, IABP at 1:3 mode resulted in a significant reduction in CBF(Dia), in a steady increase in CR(Dia), in a steady reduction in O(2) delivery and a constant increase in O(2) demand over time. IABP at the 1:2 mode had no overall effect on assessed parameters. IABP at the 1:1 mode enhanced coronary haemodynamics and cardiac contractile efficiency in an acute animal model of coronary ischaemia/reperfusion. On the contrary, IABP support set at the 1:2 or 1:3 modes failed to provide benefit. Progressive reduction in balloon inflation with a 1:1 mode instead of decreasing the heart/IABP operational ratio might represent a better IABP withdrawal protocol and is currently under investigation.
A simple analogue of lung mechanics.
Sherman, T F
1993-12-01
A model of the chest and lungs can be easily constructed from a bottle of water, a balloon, a syringe, a rubber stopper, glass and rubber tubing, and clamps. The model is a more exact analogue of the body than the classic apparatus of Hering in two respects: 1) the pleurae and intrapleural fluid are represented by water rather than air, and 2) the subatmospheric "intrapleural" pressure is created by the elasticity of the "lung" (balloon) rather than by a vacuum pump. With this model, students can readily see how the lung is inflated and deflated by movements of the "diaphragm and chest" (syringe plunger) and how intrapleural pressures change as this is accomplished.
Møller-Helgestad, Ole K; Poulsen, Christian B; Christiansen, Evald H; Lassen, Jens F; Ravn, Hanne B
2015-01-15
Cardiogenic shock as a complication to an acute myocardial infarction has an unacceptably high death rate that has not changed for the last 15years. Mortality is partly related to organ hypoperfusion and mechanical assist devices are used for the most severe cases but we do not know which assist device is the best option. Therefore, we have investigated how an IABP and an Impella®-pump influenced blood flow to the brain, heart and kidneys, in a closed-chest porcine model of severe left ventricular failure. 13 pigs were anesthetised and left ventricular failure was induced by occluding the proximal LAD for 45min followed by 30min of reperfusion. Blood flow was measured in the carotid artery, the LAD, and the renal artery. The Impella® and IABP were inserted via the femoral arteries, and the two devices were tested individually and combined after induction of heart failure. Carotid- (p=0.01) and renal blood flow (p=0.045) were higher on Impella®-support, compared to no support. None of the devices altered the blood flow in the LAD. Cardiac power output (p<0.005) and left ventricular work (p<0.00) were also higher on Impella®-support compared to no support. Haemodynamics and blood flow to the brain and kidneys were significantly better on Impella®-support, suggesting that the Impella® is superior to the IABP in a state of ischaemia induced left ventricular failure. These data, however, needs to be confirmed in a proper clinical trial with patients in cardiogenic shock. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Development of a Compact Captive Balloon and Its Level Supporting
NASA Astrophysics Data System (ADS)
Nakao, Tatsuya; Fujiwara, Kazuhito; Furukawa, Motoyasu; Hiroe, Tetsuyuki
Many kinds of observation techniques have been developed to obtain the properties of atmospheric conditions. The advanced observation techniques of the flow in relatively large scale are remote sensing by satellite facilities, long range observations by radar or Doppler Sodar, etc., while data from conventional climometers set at fixed places are merely limited information about local scale flow. Captive balloons are also available and feasible for the observation of local flows if their standing mechanics are robust against the strong wind and the motion of balloon are stable for all wind direction and the change of wind direction. In this paper, a compact captive balloon (about 2m diam.) for flow measurement is proposed and the preservation of balloon height level and the stabilization of its motion are challenged by using a kite. The relation between force balances acted on the balloon and the balloon height or position was estimated and confirmed in experiments. Although the lift force of single kite worked successfully, it is found that the performance of plural kites is less in the traction of balloon since the interaction of their tensions. The compact balloon supported by the kite enabled the over 300m floating by virtue of the small size causing only low air resistance.
[Coronary revascularization in patients with preoperative electrical storm].
Kawashima, Toshiya; Naraoka, S
2007-03-01
We report 5 cases who underwent surgical coronary revascularization for subacute myocardial ischemia with preoperative electrical storm. All patients showed severe left ventricular dysfunction. Mean ejection fraction was 24.4 +/- 7.6%. Three patients had already had implantable cardioverter-defibrillator (ICD) therapy. Procedures were on-pump coronary artery bypass grafting (CABG) and mitral valvuloplasty (MVP) [case 1], on-pump CABG, MVP, left ventricular restoration (LVR) and cryoablation (case 2), and off-pump CABG (case 3-5). Case 5 necessitated conversion to on-pump for electrical storm during left circumflex artery (LCx) anastomosis. Case 3 suddenly died on the 2nd postoperative day due to electrical storm. Case 1 had recurrent attack of electrical storm postoperatively, treated by ICD, overdrive pacing, repeated intraaortic balloon pumping (IABP), deep sedation with endotracheal intubation, and finally catheter ablation. Four patients have survived 2 years (mean) postoperatively without any arrhythmia, and are all in good condition [New York Heart Association (NYHA) I] now. It was concluded that off-pump procedure was not suitable for subacute myocardial ischemia with electrical storm and that LVR with surgical cryoablation would be effective if indicated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Logan, B.G.
A recently completed two-year study of a commercial tandem mirror reactor design (Mirror Advanced Reactor Study (MARS)) is briefly reviewed. The end plugs are designed for trapped particle stability, MHD ballooning, balanced geodesic curvature, and small radial electric fields in the central cell. New technologies such as lithium-lead blankets, 24T hybrid coils, gridless direct converters and plasma halo vacuum pumps are highlighted.
Neural Correlates of Traditional Chinese Medicine Induced Advantageous Risk-Taking Decision Making
ERIC Educational Resources Information Center
Lee, Tiffany M. Y.; Guo, Li-guo; Shi, Hong-zhi; Li, Yong-zhi; Luo, Yue-jia; Sung, Connie Y. Y.; Chan, Chetwyn C. H.; Lee, Tatia M. C.
2009-01-01
This fMRI study examined the neural correlates of the observed improvement in advantageous risk-taking behavior, as measured by the number of adjusted pumps in the Balloon Analogue Risk Task (BART), following a 60-day course of a Traditional Chinese Medicine (TCM) recipe, specifically designed to regulate impulsiveness in order to modulate…
Low-cost TDRSS communications for NASA's long duration balloon project
NASA Technical Reports Server (NTRS)
Israel, David J.
1993-01-01
A new transponder and RF ground support equipment for the NASA Tracking and Data Relay Satellite System (TDRSS) intended to support long duration scientific balloon flights in Antarctica are described. The new balloon class transponder features a highly integrated spread spectrum receiver design based on programmable charge coupled device (CCD) correlators and digital signal processing chips. The correlator chip is a Lincoln Labs 4ABC with four CCD channels. The balloon transponder is capable of reporting an estimate of its input bit error rate using digital signal processing. The TDRSS user RF test set is based on a set of RF ground support equipment capable of providing both the RF communications and direct control and monitoring necessary for transponder testing and a two-way RF link for preflight testing.
Short intra-aortic balloon pump in a swine model of myocardial ischaemia: a proof-of-concept study.
Gelsomino, Sandro; Lozekoot, Pieter W J; Lorusso, Roberto; de Jong, Monique M J; Parise, Orlando; Matteucci, Francesco; Lucà, Fabiana; La Meir, Mark; Gensini, Gian Franco; Maessen, Jos G
2016-03-01
This proof-of-concept study examined the haemodynamic performance as well as the coronary and visceral organ perfusion using a new short balloon for intra-aortic counterpulsation (IABP) in a swine model of myocardial ischaemia. Eighteen healthy pigs underwent 120-min ligation of the left anterior descending coronary artery followed by 6 h of reperfusion, and they were randomly assigned into 3 groups undergoing IABP implantation with a 35-ml short balloon (n = 6), a 40-ml short balloon (n = 6) or no IABP implantation (controls, n = 6). Haemodynamics, and visceral and coronary flows were measured at baseline (t0), at 2 h of ischaemia (t1) and every hour thereafter until 6 h of reperfusion (from tR1 to tR6), respectively. Mesenteric and renal flows increased significantly at tR1 only in the IABP groups (all, P < 0.001) and were significantly higher than controls throughout the reperfusion periods (P < 0.001). Coronary systolic and diastolic blood flows increased only at tR1 in the IABP groups (all, P < 0.001) but were higher than controls at tR1-tR6. The IABP was associated with enhanced haemodynamics compared with controls. No difference was detected using different balloon volumes (all, P > 0.05). The new short balloon significantly increased visceral flow, enhanced haemodynamics and improved coronary circulation during reperfusion following myocardial ischaemia in our experimental model. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Evolution of scientific ballooning and its impact on astrophysics research
NASA Astrophysics Data System (ADS)
Jones, William Vernon
2014-05-01
As we celebrate the centennial year of the discovery of cosmic rays on a manned balloon, it seems appropriate to reflect on the evolution of ballooning and its scientific impact. Balloons have been used for scientific research since they were invented in France more than 200 years ago. Ballooning was revolutionized in 1950 with the introduction of the so-called natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for more than a half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing the next generation super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. The Astro2010 Decadal Survey report supports super-pressure balloon development and the giant step forward it offers with ultra-long-duration balloon (ULDB) flights at constant altitudes for about 100 days.
Risky decision-making in children with and without ADHD: A prospective study.
Humphreys, Kathryn L; Tottenham, Nim; Lee, Steve S
2018-02-01
Learning from past decisions can enhance successful decision-making. It is unclear whether difficulties in learning from experience may contribute to risky decision-making, which may be altered among individuals with attention-deficit/hyperactivity disorder (ADHD). This study follows 192 children with and without ADHD aged 5 to 10 years for approximately 2.5 years and examines their risky decision-making using the Balloon Emotional Learning Task (BELT), a computerized assessment of sequential risky decision-making in which participants pump up a series of virtual balloons for points. The BELT contains three task conditions: one with a variable explosion point, one with a stable and early explosion point, and one with a stable and late explosion point. These conditions may be learned via experience on the task. Contrary to expectations, ADHD status was not found to be related to greater risk-taking on the BELT, and among younger children ADHD status is in fact associated with reduced risk-taking. In addition, the typically-developing children without ADHD showed significant learning-related gains on both stable task conditions. However, the children with ADHD demonstrated learning on the condition with a stable and early explosion point, but not on the condition with the stable and late explosion point, in which more pumps are required before learning when the balloon will explode. Learning during decision-making may be more difficult for children with ADHD. Because adapting to changing environmental demands requires the use of feedback to guide future behavior, negative outcomes associated with childhood ADHD may partially reflect difficulties in learning from experience.
Students' Investigations in Temperature and Pressure
ERIC Educational Resources Information Center
Brown, Patrick L.; Concannon, James; Hansert, Bernhard; Frederick, Ron; Frerichs, Glen
2015-01-01
Why does a balloon deflate when it is left in a cold car; or why does one have to pump up his or her bike tires in the spring after leaving them in the garage all winter? To answer these questions, students must understand the relationships among temperature, pressure, and volume of a gas. The purpose of the Predict, Share, Observe, and Explain…
Bridge to transplantation with a left ventricular assist device.
Jung, Jae Jun; Sung, Kiick; Jeong, Dong Seop; Kim, Wook Sung; Lee, Young Tak; Park, Pyo Won
2012-04-01
A 61-year-old female patient was diagnosed with dilated cardiomyopathy with severe left ventricle dysfunction. Two days after admission, continuous renal replacement therapy was performed due to oliguria and lactic acidosis. On the fifth day, an intra-aortic balloon pump was inserted due to low cardiac output syndrome. Beginning 4 days after admission, she was supported for 15 days thereafter with an extracorporeal left ventricular assist device (LVAD) because of heart failure with multi-organ failure. A heart transplant was performed while the patient was stabilized with the LVAD. She developed several complications after the surgery, such as cytomegalovirus pneumonia, pulmonary tuberculosis, wound dehiscence, and H1N1 infection. On postoperative day 19, she was discharged from the hospital with close follow-up and treatment for infection. She received follow-up care for 10 months without any immune rejection reaction.
Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R; Khir, Ashraf W
2015-08-01
The intra-aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre-, intra-, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi-recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra-aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. Copyright © 2015 The Authors. Artificial Organs published by Wiley Periodicals, Inc. on behalf of International Center for Artificial Organ and Transplantation (ICAOT).
Iridium: Global OTH data communications for high altitude scientific ballooning
NASA Astrophysics Data System (ADS)
Denney, A.
While the scientific community is no stranger to embracing commercially available technologies, the growth and availability of truly affordable cutting edge technologies is opening the door to an entirely new means of global communications. For many years high altitude ballooning has provided science an alternative to costly satellite based experimental platforms. As with any project, evolution becomes an integral part of development. Specifically in the NSBF ballooning program, where flight durations have evolved from the earlier days of hours to several weeks and plans are underway to provide missions up to 100 days. Addressing increased flight durations, the harsh operational environment, along with cumbersome and outdated systems used on existing systems, such as the balloon vehicles Support Instrumentation Package (SIP) and ground-based systems, a new Over-The-Horizon (OTH) communications medium is sought. Current OTH equipment planning to be phased-out include: HF commanding systems, ARGOS PTT telemetry downlinks and INMARSAT data terminals. Other aspects up for review in addition to the SIP to utilize this communications medium include pathfinder balloon platforms - thereby, adding commanding abilities and increased data rates, plus providing a package for ultra-small experiments to ride aloft. Existing communication systems employed by the National Scientific Balloon Facility ballooning program have been limited not only by increased cost, slow data rates and "special government use only" services such as TDRSS (Tracking and Data Relay Satellite System), but have had to make special provisions to geographical flight location. Development of the Support Instrumentation Packages whether LDB (Long Duration Balloon), ULDB (Ultra Long Duration Balloon) or conventional ballooning have been plagued by non-standard systems configurations requiring additional support equipment for different regions and missions along with a myriad of backup for redundancy. Several beneficial points provided by the Iridium platform include pure global accessibility (as well as polar), cost effectiveness because it is available as a COTS (Commercially Off The Shelf) technology, reliability in that the equipment must operate in extreme conditions (near space), integration and development time into current systems must be minimized. As a bonus Motorola and NAL Research Corporation are developing SBD (Short Burst Data) into the Iridium network. This may lead the way to a global IP (Internet Protocol) node based ballooning platform. The Iridium satellite data modems employ the Iridium Low-Earth Orbit (LEO) satellite network. The scope of this paper is to introduce an OTH communications alternative, albeit not necessarily a primary one, to existing ballooning platforms using COTS based emerging technologies. Design aspects, characteristics, actual flight testing statistics, principles of the Iridium modems and communication paths are described including payload and support instrumentation interfacing. Not limited to high altitude ballooning, the Iridium communications platform opens a new era in remote commanding and data retrieval.
Esophageal stenosis in epidermolysis bullosum: a challenge for the endoscopist.
De Angelis, Paola; Caldaro, Tamara; Torroni, Filippo; Romeo, Erminia; Foschia, Francesca; di Abriola, Giovanni Federici; Rea, Francesca; El Hachem, May; Genovese, Elisabetta; D'Alessandro, Sandra; Dall'Oglio, Luigi
2011-05-01
Esophageal stenosis is a severe complication in dystrophic epidermolysis bullosa (EB). Endoscopic dilations may cause mucosal injury with stricture recurrence. Our aim was to describe our referral EB-center experience on safety and long-term efficacy of fluoroscopically guided balloon dilation without endoscopy. Over 14 years, 34 patients with EB, previously evaluated with barium esophagogram for dysphagia, underwent balloon esophageal dilation. Under fluoroscopy, a guide wire was introduced via a nostril into the stomach. A 12-mm pneumatic balloon, which passed over the wire, was filled using radio-opaque contrast, dilating the stricture. Orotracheal intubation was avoided. Antibiotics, dexamethasone, and proton-pump inhibitors were administered. Study approval was obtained from our ethical board. Ninety-three dilations were performed. Seventeen patients had a single stenosis. The mean age of onset was 18 years (range, 3-47 years). Thirteen patients underwent one dilation. In 6 cases, endoscopy was necessary to visualize the esophageal lumen. Complications included cervical esophageal perforation (2) and transitory dysphagia (10). Thirty patients were feeding within 24 hours. During the follow-up, 2 patients required a gastrostomy, and 2 patients underwent fundoplication for gastroesophageal reflux disease. Fluoroscopically guided balloon dilation in EB is a safe and well-tolerated procedure. An experienced endoscopy team is necessary in certain cases. Copyright © 2011 Elsevier Inc. All rights reserved.
Recent Results and Near Term Outlook for the NASA Balloon Science Program
NASA Astrophysics Data System (ADS)
Jones, William Vernon
Long-duration and conventional balloon flights in the traditional Astrophysics, Solar and Heliophysics, and Earth Science disciplines have continued in both polar and non-polar regions since the 39th COSPAR Assembly in Mysore, India. One of these established a new flight record of 55 days over Antarctica during the 2012-2013 austral season. That Super-TIGER science flight broke both the 42-day record of the CREAM science flight during the 2004-2005 season and the 54-day super pressure balloon test flight in 2008-2009. With two comets approaching the sun in 2013-2014, the Planetary Science community has shown increased interest in remote observations of comets, planets, and other objects in the Solar System. All of the above science disciplines are interested in super pressure balloon (SPB) flights, which have been under development by NASA, and which were strongly supported by the Astro2010 Decadal Study. A 532,152 m3 (18.8 MCF) SPB with a major gamma ray astrophysics payload is planned for an ultra-long duration balloon (ULDB) test flight around and from Antarctica during the upcoming 2014-2015 season. Flights for SPB qualification to support 1000 kg science instruments to 33 km altitude have proceeded in parallel with planning for options to increase the altitude for less massive instruments that require less atmospheric overburden. The nearly constant SPB volume will provide stable altitude long-duration flights at non-polar latitudes, thereby supporting a much broader range of scientific investigations. Scientific ballooning continues to complement and enable space missions, while training young scientists and systems engineers for the workforce needed to conduct future missions. Highlights of results from past balloon-borne measurements and expected results from ongoing and planned balloon-borne experiments will be presented.
Balloon concepts for scientific investigation of Mars and Jupiter
NASA Technical Reports Server (NTRS)
Ash, R. L.
1979-01-01
Opportunities for scientific investigation of the atmospheric planets using buoyant balloons have been explored. Mars and Jupiter were considered in this study because design requirements at those planets bracket nominally the requirements at Venus, and plans are already underway for a joint Russian-French balloon system at Venus. Viking data has provided quantitative information for definition of specific balloon systems at Mars. Free flying balloons appear capable of providing valuable scientific support for more sophisticated Martian surface probes, but tethered and powered aerostats are not attractive. The Jovian environment is so extreme, hot atmosphere balloons may be the only scientific platforms capable of extended operations there. However, the estimated system mass and thermal energy required are very large.
Cryo-balloon catheter localization in fluoroscopic images
NASA Astrophysics Data System (ADS)
Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert
2013-03-01
Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.
Valk, S D A; Cheng, J M; den Uil, C A; Lagrand, W K; van der Ent, M; van de Sande, M; van Domburg, R T; Simoons, M L
2011-03-01
OBJECTIVE: To evaluate a 30-day and long-term outcome of patients with acute myocardial infarction (AMI) treated with intra-aortic balloon pump (IABP) counterpulsation and to identify predictors of a 30-day and long-term all-cause mortality. METHODS: Retrospective cohort study of 437 consecutive AMI patients treated with IABP between January 1990 and June 2004. A Cox proportional hazards model was used to identify predictors of a 30-day and long-term all-cause mortality. RESULTS: Mean age of the study population was 61 ± 11 years, 80% of the patients were male, and 68% had cardiogenic shock. Survival until IABP removal after successful haemodynamic stabilisation was 78% (n = 341). Cumulative 30-day survival was 68%. Median follow-up was 2.9 years (range, 6 months to 15 years). In patients who survived until IABP removal, cumulative 1-, 5-, and 10-year survival was 75%, 61%, and 39%, respectively. Independent predictors of higher long-term mortality were prior cerebrovascular accident (hazard ratio (HR), 1.8; 95% confidence interval (CI), 1.0-3.4), need for antiarrhythmic drugs (HR, 2.3; 95% CI, 1.5-3.3), and need for renal replacement therapy (HR, 2.3; 95% CI, 1.2-4.3). Independent predictors of lower long-term mortality were primary percutaneous coronary intervention (PCI; HR, 0.6; 95% CI, 0.4-1.0), failed thrombolysis with rescue PCI (HR, 0.5; 95% CI, 0.3-0.9), and coronary artery bypass grafting (HR, 0.3; 95% CI, 0.1-0.5). CONCLUSIONS: Despite high in-hospital mortality in patients with AMI treated with IABP, a favourable number of patients survived in the long-term. These results underscore the value of aggressive haemodynamic support of patients throughout the acute phase of AMI.
Bartoli, Carlo R.; Rogers, Benjamin D.; Ionan, Constantine E.; Koenig, Steven C.; Pantalos, George M.
2013-01-01
OBJECTIVE Counterpulsation with an intraaortic balloon pump (IABP) has not achieved the same successes or clinical use in pediatric patients as in adults. In a pediatric animal model, IABP efficacy was investigated to determine whether IABP timing with a high-fidelity blood pressure signal may improve counterpulsation therapy versus a low-fidelity signal. METHODS In Yorkshire piglets (n=19, 13.0±0.5 kg) with coronary ligation-induced acute ischemic left ventricular failure, pediatric IABPs (5 or 7cc) were placed in the descending thoracic aorta. Inflation and deflation were timed with traditional criteria from low-fidelity (fluid-filled) and high-fidelity (micromanometer) blood pressure signals during 1:1 support. Aortic, carotid, and coronary hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption was calculated from coronary sinus and arterial blood samples. Left ventricular myocardial blood flow and end-organ blood flow were measured with microspheres. RESULTS Despite significant suprasystolic diastolic augmentation and afterload reduction at heart rates of 105±3bmp, left ventricular myocardial blood flow, myocardial oxygen consumption, the myocardial oxygen supply/demand relationship, cardiac output, and end-organ blood flow did not change. Statistically significant end-diastolic coronary, carotid, and aortic flow reversal occurred with IABP deflation. Inflation and deflation timed with a high-fidelity versus low-fidelity signal did not attenuate systemic flow reversal or improve the myocardial oxygen supply/demand relationship. CONCLUSIONS Systemic end-diastolic flow reversal limited counterpulsation efficacy in a pediatric model of acute left ventricular failure. Adjustment of IABP inflation and deflation timing with traditional criteria and a high-fidelity blood pressure waveform did not improve IABP efficacy or attenuate flow reversal. End-diastolic flow reversal may limit the efficacy of IABP counterpulsation therapy in pediatric patients with traditional timing criteria. Investigation of alternative deflation timing strategies is warranted. PMID:24139614
Bartoli, Carlo R; Rogers, Benjamin D; Ionan, Constantine E; Pantalos, George M
2014-05-01
Counterpulsation with an intra-aortic balloon pump (IABP) has not achieved the same success or clinical use in pediatric patients as in adults. In a pediatric animal model, IABP efficacy was investigated to determine whether IABP timing with a high-fidelity blood pressure signal may improve counterpulsation therapy versus a low-fidelity signal. In Yorkshire piglets (n = 19; weight, 13.0 ± 0.5 kg) with coronary ligation-induced acute ischemic left ventricular failure, pediatric IABPs (5 or 7 mL) were placed in the descending thoracic aorta. Inflation and deflation were timed with traditional criteria from low-fidelity (fluid-filled) and high-fidelity (micromanometer) blood pressure signals during 1:1 support. Aortic, carotid, and coronary hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption was calculated from coronary sinus and arterial blood samples. Left ventricular myocardial blood flow and end-organ blood flow were measured with microspheres. Despite significant suprasystolic diastolic augmentation and afterload reduction at heart rates of 105 ± 3 beats per minute, left ventricular myocardial blood flow, myocardial oxygen consumption, the myocardial oxygen supply/demand relationship, cardiac output, and end-organ blood flow did not change. Statistically significant end-diastolic coronary, carotid, and aortic flow reversal occurred with IABP deflation. Inflation and deflation timed with a high-fidelity versus low-fidelity signal did not attenuate systemic flow reversal or improve the myocardial oxygen supply/demand relationship. Systemic end-diastolic flow reversal limited counterpulsation efficacy in a pediatric model of acute left ventricular failure. Adjustment of IABP inflation and deflation timing with traditional criteria and a high-fidelity blood pressure waveform did not improve IABP efficacy or attenuate flow reversal. End-diastolic flow reversal may limit the efficacy of IABP counterpulsation therapy in pediatric patients with traditional timing criteria. Investigation of alternative deflation timing strategies is warranted. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Balloon borne in-situ detection of OH in the stratosphere from 37 to 23 km
NASA Technical Reports Server (NTRS)
Stimpfle, R. M.; Lapson, L. B.; Wennberg, P. O.; Anderson, J. G.
1989-01-01
The OH number density in the stratosphere has been measured over the altitude interval of 37 to 23 km at midday via a balloon-borne gondola launched from Palestine, Texas on July 6, 1988. OH radicals are detected with a laser-induced fluorescence instrument employing a 17-kHz-repetition-rate copper vapor laser-pumped dye laser optically coupled to an enclosed flow, in-situ sampling chamber. OH abundances ranged from 88 + or - 3l pptv in the 36 to 35 km interval to 0.9 + or - 0.8 pptv in the 24 to 23 km interval. The stated uncertainty includes that from both measurement precision and accuracy. Simultaneous detection of ozone and water vapor densities was carried out with separate on-board instruments.
Mechanical Circulatory Support of the Critically Ill Child Awaiting Heart Transplantation
Gazit, Avihu Z; Gandhi, Sanjiv K; C Canter, Charles
2010-01-01
The majority of children awaiting heart transplantation require inotropic support, mechanical ventilation, and/or extracorporeal membrane oxygenation (ECMO) support. Unfortunately, due to the limited pool of organs, many of these children do not survive to transplant. Mechanical circulatory support of the failing heart in pediatrics is a new and rapidly developing field world-wide. It is utilized in children with acute congestive heart failure associated with congenital heart disease, cardiomyopathy, and myocarditis, both as a bridge to transplantation and as a bridge to myocardial recovery. The current arsenal of mechanical assist devices available for children is limited to ECMO, intra-aortic balloon counterpulsation, centrifugal pump ventricular assist devices, the DeBakey ventricular assist device Child; the Thoratec ventricular assist device; and the Berlin Heart. In the spring of 2004, five contracts were awarded by the National Heart, Lung and Blood Institute to support preclinical development for a range of pediatric ventricular assist devices and similar circulatory support systems. The support of early development efforts provided by this program is expected to yield several devices that will be ready for clinical trials within the next few years. Our work reviews the current international experience with mechanical circulatory support in children and summarizes our own experience since 2005 with the Berlin Heart, comparing the indications for use, length of support, and outcome between these modalities. PMID:21286278
Kim, Chang-Hyun; Song, Kwang-Soup; Trayanova, Natalia A; Lim, Ki Moo
2018-05-01
Intra-aortic balloon pump (IABP) is normally contraindicated in significant aortic regurgitation (AR). It causes and aggravates pre-existing AR while performing well in the event of mitral regurgitation (MR). Indirect parameters, such as the mean systolic pressure, product of heart rate and peak systolic pressure, and pressure-volume are used to quantify the effect of IABP on ventricular workload. However, to date, no studies have directly quantified the reduction in workload with IABP. The goal of this study is to examine the effect of IABP therapy on ventricular mechanics under valvular insufficiency by using a computational model of the heart. For this purpose, the 3D electromechanical model of the failing ventricles used in previous studies was coupled with a lumped parameter model of valvular regurgitation and the IABP-treated vascular system. The IABP therapy was disturbed in terms of reducing the myocardial tension generation and contractile ATP consumption by valvular regurgitation, particularly in the AR condition. The IABP worsened the problem of ventricular expansion induced as a result of the regurgitated blood volume during the diastole under the AR condition. The IABP reduced the LV stroke work in the AR, MR, and no regurgitation conditions. Therefore, the IABP helped the ventricle to pump blood and reduced the ventricular workload. In conclusion, the IABP partially performed its role in the MR condition. However, it was disturbed by the AR and worsened the cardiovascular responses that followed the AR. Therefore, this study computationally proved the reason for the clinical contraindication of IABP in AR patients.
Etienne, Pierre Yves; Papadatos, Spiridon; Glineur, David; Mairy, Yves; El Khoury, Elie; Noirhomme, Philippe; El Khoury, Gebrine
2007-08-01
Preoperative intraaortic balloon pump (IABP) counterpulsation has better outcomes compared with perioperative or postoperative insertion in critical patients, and off-pump surgical procedures have been advocated to reduce mortality in high-risk patients. However, some surgeons are reluctant to perform beating heart operations in specific patient subgroups, including those with unstable angina or patients with low ejection fraction, because of their possible perioperative hemodynamic instability. We evaluated combined beating heart procedures and preoperative IABP in selected high-risk patients and compared our results with the predictive European System for Cardiac Operative Risk Evaluation (EuroSCORE) model. Fifty-five high-risk patients with a mean logistic EuroSCORE of 24 were prospectively enrolled and then divided into emergency (group 1, n = 25) and nonemergency (group 2, n = 30) groups. IABP was inserted immediately before operation in group 1 and the day before the procedure in group 2. Compared with the EuroSCORE predictive model, a dramatic decrease in mortality occurred in both groups. Group I predicted mortality was 36.8%, and observed was 20%; and group 2 predicted mortality was 15.2% and observed was 0%. No specific complications from the use of IABP were encountered. During mid-term (2 years) follow-up, no patient died from a cardiac cause or required percutaneous coronary intervention or subsequent reoperation due to incomplete revascularization. The combined use of preoperative intraaortic counterpulsation and beating heart intervention allows complete revascularization in high-risk patients with a important reduction in operative mortality and excellent mid-term results.
NASA’s BARREL Mission Launches 20 Balloons
2017-12-08
Pumping helium into the first BARREL balloon to launch from Halley Research Satation. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
National Report on the NASA Sounding Rocket and Balloon Programs
NASA Technical Reports Server (NTRS)
Eberspeaker, Philip; Fairbrother, Debora
2013-01-01
The U. S. National Aeronautics and Space Administration (NASA) Sounding Rockets and Balloon Programs conduct a total of 30 to 40 missions per year in support of the NASA scientific community and other users. The NASA Sounding Rockets Program supports the science community by integrating their experiments into the sounding rocket payloads, and providing both the rocket vehicle and launch operations services. Activities since 2011 have included two flights from Andoya Rocket Range, more than eight flights from White Sands Missile Range, approximately sixteen flights from Wallops Flight Facility, two flights from Poker Flat Research Range, and four flights from Kwajalein Atoll. Other activities included the final developmental flight of the Terrier-Improved Malemute launch vehicle, a test flight of the Talos-Terrier-Oriole launch vehicle, and a host of smaller activities to improve program support capabilities. Several operational missions have utilized the new Terrier-Malemute vehicle. The NASA Sounding Rockets Program is currently engaged in the development of a new sustainer motor known as the Peregrine. The Peregrine development effort will involve one static firing and three flight tests with a target completion data of August 2014. The NASA Balloon Program supported numerous scientific and developmental missions since its last report. The program conducted flights from the U.S., Sweden, Australia, and Antarctica utilizing standard and experimental vehicles. Of particular note are the successful test flights of the Wallops Arc Second Pointer (WASP), the successful demonstration of a medium-size Super Pressure Balloon (SPB), and most recently, three simultaneous missions aloft over Antarctica. NASA continues its successful incremental design qualification program and will support a science mission aboard WASP in late 2013 and a science mission aboard the SPB in early 2015. NASA has also embarked on an intra-agency collaboration to launch a rocket from a balloon to conduct supersonic decelerator tests. An overview of NASA's Sounding Rockets and Balloon Operations, Technology Development and Science support activities will be presented.
NASA Astrophysics Data System (ADS)
Orr, Dwayne
The Columbia Scientific Balloon Facility (CSBF) at Palestine, Texas provides operational and engineering support for the launch of NASA Scientific Balloons. Over the years with the support of the NASA Balloon Program Office, CSBF has developed unique flight systems with the focus of providing a highly reliable, cost effective medium for giving Scientist's access to a near space environment. This paper will provide an overview of the CSBF flight systems with an emphasis on recent developments and plans for the future including: RIP Stitch -Parachute Shock Attenuation system, MIP -Micro Instrumentation Package, GAPR -Gondola Automatic Parachute Release system, NASA TDRSS High Gain Antenna system, Superpressure flight video systems
O'Shea, Owen R; Hamann, Mark; Smith, Walter; Taylor, Heidi
2014-02-15
Efforts to curb pollution in the marine environment are covered by national and international legislation, yet weather balloons are released into the environment with no salvage agenda. Here, we assess impacts associated with weather balloons in the Great Barrier Reef World Heritage Area (GBRWHA). We use modeling to assess the probability of ocean endpoints for released weather balloons and predict pathways post-release. In addition, we use 21 months of data from beach cleanup events to validate our results and assess the abundance and frequency of weather balloon fragments in the GBRWHA. We found between 65% and 70% of balloons land in the ocean and ocean currents largely determine final endpoints. Beach cleanup data revealed 2460 weather balloon fragments were recovered from 24 sites within the GBRWHA. This is the first attempt to quantify this problem and these data will add support to a much-needed mitigation strategy for weather balloon waste. Copyright © 2013 Elsevier Ltd. All rights reserved.
Modular and Reusable Power System Design for the BRRISON Balloon Telescope
NASA Astrophysics Data System (ADS)
Truesdale, Nicholas A.
High altitude balloons are emerging as low-cost alternatives to orbital satellites in the field of telescopic observation. The near-space environment of balloons allows optics to perform near their diffraction limit. In practice, this implies that a telescope similar to the Hubble Space Telescope could be flown for a cost of tens of millions as opposed to billions. While highly feasible, the design of a balloon telescope to rival Hubble is limited by funding. Until a prototype is proven and more support for balloon science is gained, projects remain limited in both hardware costs and man hours. Thus, to effectively create and support balloon payloads, engineering designs must be efficient, modular, and if possible reusable. This thesis focuses specifically on a modular power system design for the BRRISON comet-observing balloon telescope. Time- and cost-saving techniques are developed that can be used for future missions. A modular design process is achieved through the development of individual circuit elements that span a wide range of capabilities. Circuits for power conversion, switching and sensing are designed to be combined in any configuration. These include DC-DC regulators, MOSFET drivers for switching, isolated switches, current sensors and voltage sensing ADCs. Emphasis is also given to commercially available hardware. Pre-fabricated DC-DC converters and an Arduino microcontroller simplify the design process and offer proven, cost-effective performance. The design of the BRRISON power system is developed from these low-level circuits elements. A board for main power distribution supports the majority of flight electronics, and is extensible to additional hardware in future applications. An ATX computer power supply is developed, allowing the use of a commercial ATX motherboard as the flight computer. The addition of new capabilities is explored in the form of a heater control board. Finally, the power system as a whole is described, and its overall performance analyzed. The success of the BRRISON power system during testing and flight proves its utility, both for BRRISON and for future balloon telescopes.
NASA Technical Reports Server (NTRS)
Murcray, D. G.; Brooks, J. N.; Kosters, J. J.; Williams, W. J.
1975-01-01
A balloon flight was conducted with a sensitive infrared spectral radiometer system in support of the LACATE balloon experiment. The instrumentation aboard the balloon is described along with data reduction techniques. Results obtained during the flight are presented.
Balloon Borne Ultraviolet Spectrometer.
1978-12-28
n.c.aaary ond lden lfy by block numb.r) ultraviolet ground support equipment (GSE) spectrometers flight electronics instrumentation balloons \\ solar ...Assembly 4 Fig. 3 Solar Balloon Experiment Ass ’y 7 Fig. 4 Mechanical Interface , UV Spectrometer 8 Fig . 5 Spectrometer Body Assemb ly 10 Fig. 6...Diagram, GSE )bnitor 48 Selector and Battery Charger Fig. 25 Schematic Diagram, GSE Serial to 49 Parallel Data Converter Fig. 26 Schematic Diagram
Alkaptonuric aortic stenosis: a case report.
Gonzales, M E
1999-04-01
Alkaptonuria is a rare disease of phenylalanine, aromatic amino acids, and tyrosine metabolism. Because of a genetic deficiency of the enzyme homogentisic acid oxidase, an accumulation of homogentisic acid causes ochronotic pigment deposition. The most common clinical manifestations are arthropathy, urinary calculi and discoloration, cutaneous and cartilaginous pigmentation, and cardiac valvular disease. Arthropathy and aortic stenosis are the most debilitating manifestations of the disease. A case of alkaptonuric aortic stenosis is described. A 75-year-old woman with a history of alkaptonuria presented in the emergency department with complaints of progressive dyspnea. Upon examination, the patient was hypertensive, tachypneic, and tachycardic with premature ventricular contractions. She had pitting edema of the lower extremities and complaints of generalized weakness. Chest x-rays revealed congestive heart failure and pulmonary edema. Diuretics were administered, and a continuous nitroglycerin infusion was initiated in the emergency department. The patient was admitted for further evaluation. The patient's respiratory status continued to decline. She was intubated endotracheally 1 day after admission. Subsequent cardiac evaluation revealed an ejection fraction of 35%, severe aortic stenosis, mild coronary artery disease, ischemic cardiomyopathy, and anteroapical akinesis. A dobutamine infusion was instituted for persistent hypotension, and renal dose dopamine was initiated for oliguric renal failure. The patient underwent an emergency operation for an aortic valve replacement with a Dacron patch 10 days after admission. Cardiopulmonary bypass and mild hypothermia were used during the procedure. The patient's hemodynamic status remained tenuous throughout the procedure. Although the first attempt to wean off cardiopulmonary bypass failed, the second attempt was successful with the aid of an intra-aortic balloon pump, inotropic support, and atrioventricular pacing. These measures were maintained during transport to the surgical intensive care unit. In the intensive care unit, the patient did not have an audible blood pressure or a palpable pulse without the support of the intra-aortic balloon pump and atrioventricular pacing. Coarse atrial fibrillation was the underlying electrocardiogram rhythm in the absence of atrioventricular pacing. Sodium bicarbonate was given without improvement. After discussion with the family, all life support measures were discontinued. The patient died 10 minutes after her arrival in the intensive care unit. Alkaptonuria's pathogenesis is manifested as both local and systemic in nature. Collagen vascular diseases share a similar pattern of multisystem involvement. Despite the negative outcome for the patient described, valuable insight can be obtained by studying this case and noting the anesthetic considerations specific to collagen vascular diseases in general.
Balloon-borne three-meter telescope for far-infrared and submillimeter astronomy
NASA Technical Reports Server (NTRS)
Fazio, Giovanni G.; Hoffmann, William F.; Harper, Doyal A.
1988-01-01
The scientific objectives, engineering analysis and design, results of technology development, and focal-plane instrumentation for a two-meter balloon-borne telescope for far-infrared and submillimeter astronomy are presented. The unique capabilities of balloon-borne observations are discussed. A program summary emphasizes the development of the two-meter design. The relationship of the Large Deployable Reflector (LDR) is also discussed. Detailed treatment is given to scientific objectives, gondola design, the mirror development program, experiment accommodations, ground support equipment requirements, NSBF design drivers and payload support requirements, the implementation phase summary development plan, and a comparison of three-meter and two-meter gondola concepts.
The response of the microcirculation to mechanical support of the heart in critical illness.
Akin, Sakir; Kara, Atila; den Uil, Corstiaan A; Ince, Can
2016-12-01
Critical illness associated with cardiac pump failure results in reduced tissue perfusion in all organs and occurs in various conditions such as sepsis, cardiogenic shock, and heart failure. Mechanical circulatory support (MCS) devices can be used to maintain organ perfusion in patients with cardiogenic shock and decompensated chronic heart failure. However, correction of global hemodynamic parameters by MCS does not always cause a parallel improvement in microcirculatory perfusion and oxygenation of the organ systems, a condition referred to as a loss of hemodynamic coherence between macro- and microcirculation (MC). In this paper, we review the literature describing hemodynamic coherence or loss occurring during MCS of the heart. By using Embase, Medline Cochrane, Web of Science, and Google Scholar, we analyzed the literature on the response of MC and macrocirculation to MCS of the heart in critical illness. The characteristics of patients, MCS devices, and micro- and macrocirculatory parameters were very heterogenic. Short-term MCS studies (78%) described the effects of intra-aortic balloon pumps (IABPs) on the MC and macrocirculation. Improvement in MC, observed by handheld microscopy (orthogonal polarization spectral (OPS), sidestream dark-field (SDF), and Cytocam IDF imaging) in line with restored macrocirculation was found in 44% and 40% of the studies of short- and long-term MCS, respectively. In only 6 of 14 studies, hemodynamic coherence was described. It is concluded that more studies using direct visualization of the MC in short- and long-term MCS by handheld microscopy are needed, preferably randomized controlled studies, to identify the presence and clinical significance of hemodynamic coherence. It is anticipated that these further studies can enable to better identify patients who will benefit from treatment by mechanical heart support to ensure adequate organ perfusion. Copyright © 2016 Elsevier Ltd. All rights reserved.
Radiology of cardiac devices and their complications
Dipoce, J; Spindola-Franco, H
2015-01-01
This article familiarizes the reader with several different cardiac devices including pacemakers and implantable cardioverter defibrillators, intra-aortic balloon pumps, ventricular assist devices, valve replacements and repairs, shunt-occluding devices and passive constraint devices. Many cardiac devices are routinely encountered in clinical practice. Other devices are in the early stages of development, but circumstances suggest that they too will become commonly found. The radiologist must be familiar with these devices and their complications. PMID:25411826
Refractory Coronary Artery Spasm after Minimally Invasive Direct Coronary Artery Bypass Grafting
Ju, Min Ho; Kim, Joon-Bum; Kim, Hee Jung
2011-01-01
Postoperative coronary arterial spasm is a rare but potentially fatal complication. A 51-year-old male patient with a history of a reactive ergonovine stress test coronary angiogram developed refractory coronary artery spasm after undergoing minimally invasive direct coronary artery bypass grafting of the left anterior descending coronary artery. The patient was successfully managed with rapid implementation of intra-aortic balloon-pump counter pulsation and extracorporeal membrane oxygenation. PMID:22263171
A computer model of the pediatric circulatory system for testing pediatric assist devices.
Giridharan, Guruprasad A; Koenig, Steven C; Mitchell, Michael; Gartner, Mark; Pantalos, George M
2007-01-01
Lumped parameter computer models of the pediatric circulatory systems for 1- and 4-year-olds were developed to predict hemodynamic responses to mechanical circulatory support devices. Model parameters, including resistance, compliance and volume, were adjusted to match hemodynamic pressure and flow waveforms, pressure-volume loops, percent systole, and heart rate of pediatric patients (n = 6) with normal ventricles. Left ventricular failure was modeled by adjusting the time-varying compliance curve of the left heart to produce aortic pressures and cardiac outputs consistent with those observed clinically. Models of pediatric continuous flow (CF) and pulsatile flow (PF) ventricular assist devices (VAD) and intraaortic balloon pump (IABP) were developed and integrated into the heart failure pediatric circulatory system models. Computer simulations were conducted to predict acute hemodynamic responses to PF and CF VAD operating at 50%, 75% and 100% support and 2.5 and 5 ml IABP operating at 1:1 and 1:2 support modes. The computer model of the pediatric circulation matched the human pediatric hemodynamic waveform morphology to within 90% and cardiac function parameters with 95% accuracy. The computer model predicted PF VAD and IABP restore aortic pressure pulsatility and variation in end-systolic and end-diastolic volume, but diminish with increasing CF VAD support.
Mathematical modelling of intra-aortic balloon pump.
Abdolrazaghi, Mona; Navidbakhsh, Mahdi; Hassani, Kamran
2010-10-01
Ischemic heart diseases now afflict thousands of Iranians and are the major cause of death in many industrialised countries. Mathematical modelling of an intra-aortic balloon pump (IABP) could provide a better understanding of its performance and help to represent blood flow and pressure in systemic arteries before and after inserting the pump. A mathematical modelling of the whole cardiovascular system was formulated using MATLAB software. The block diagram of the model consists of 43 compartments. All the anatomical data was extracted from the physiological references. In the next stage, myocardial infarction (MI) was induced in the model by decreasing the contractility of the left ventricle. The IABP was mathematically modelled and inserted in the model in the thoracic aorta I artery just before the descending aorta. The effects of IABP on MI were studied using the mathematical model. The normal operation of the cardiovascular system was studied firstly. The pressure-time graphs of the ventricles, atriums, aorta, pulmonary system, capillaries and arterioles were obtained. The volume-time curve of the left ventricle was also presented. The pressure-time curves of the left ventricle and thoracic aorta I were obtained for normal, MI, and inserted IABP conditions. Model verification was performed by comparing the simulation results with the clinical observations reported in the literature. IABP can be described by a theoretical model. Our model representing the cardiovascular system is capable of showing the effects of different pathologies such as MI and we have shown that MI effects can be reduced using IABP in accordance with the modelling results. The mathematical model should serve as a useful tool to simulate and better understand cardiovascular operation in normal and pathological conditions.
Incorporation of Scientific Ballooning into Science Education
NASA Astrophysics Data System (ADS)
Chanover, N.; Stochaj, S.; Petty, C.
1999-12-01
We are augmenting the science curriculum of the Roswell Independent School District in Roswell, NM, to take advantage of the proximity of a NASA scientific balloon base. The basic science related to balloon experimentation is being incorporated into the K-12 science curriculum via the discussion of topics such as atmospheric properties, weather, phases of matter, plotting skills, and communications in the context of a high-altitude balloon flight. These efforts will culminate in the construction of balloon-borne instruments by high school students, which will be launched during the spring of 2000. A demonstration flight, launched in the spring of 1999, was used to build student enthusiasm and community support for this program, which is funded by the NASA/IDEAS program.
Nimbus 4/IRLS Balloon Interrogation Package (BIP)
NASA Technical Reports Server (NTRS)
1971-01-01
The balloon interrogation package (BIP), an integral part of the overall interrogation, recording, and location subsystems (IRLS) for the Nimbus 4 program, is described. The BIP is a self-contained, integrated transponder designed to be carried aloft by a constant altitude, superpressure balloon to an altitude of 67,000 or 78,000 feet. After launch the BIP senses high-altitude balloon overpressure and temperature, and upon receipt of an interrogated command from the IRLS aboard the Nimbus 4 satellite, the BIP enodes the data on a real-time basis into a pulse-code modulation (PCM) format and transmits this data to the satellite. A summary of the program activity to produce 30 BIP systems and to support balloon launches from Ascension Island is presented.
The Micro-Instrumentation Package: A Solution to Lightweight Ballooning
NASA Astrophysics Data System (ADS)
Juneau, Jill
This paper discusses the design and testing of an over the horizon (OTH) light weight telemetry and termination system that can be used for small ballooning payloads. Currently, the Columbia Scientific Balloon Facility (CSBF) provides telemetry for the science payload by integrating one of two types of support packages. The type of support package integrated depends on whether the flight will stay in range of line of sight (LOS) or will exceed LOS requiring the use of over the horizon (OTH) telemetry. The weights of these systems range from 100 pounds to 350 pounds depending upon the use of redundant systems, equipment for high data rates, and batteries and/or solar panels for power requirements. These weight values are not as significant for larger payloads but can be crippling for smaller payloads. In addition, these support package systems are fairly expensive, placing a high importance on recovery. A lightweight and inexpensive telemetry system could be beneficial for various reasons. First, it would allow scientists to fly lightweight payloads on large balloons reaching even higher altitudes. Second, scientists could fly lightweight payloads on less expensive balloons such as meteorological balloons. Depending on the payload, these flights could be fairly inexpensive and even disposable. Third, a compact telemetry system on any balloon will free up more room for the science portion of the payload. In response, a compact telemetry/termination system called the Micro-Instrumentation Package (MIP) was developed. The MIP provides uplink and downlink communications, an interface to the science, housekeeping information including global positioning system (GPS) position, and relays. Instead of a power-hungry microprocessor, the MIP's central consists of a microcontroller. Microcontrollers are lower power, easily programmed, and can be purchased for less than ten dollars. For uplink and downlink telemetry, the MIP uses an LOS serial transceiver and an Iridium unit for OTH flights. A relay deck is also included for powering subsystems and for flight termination. Furthermore, the science will be able to interface to the MIP through a serial connection, although the data rates for the science interface will be limited compared to those of standard telemetry support packages. Overall, the MIP provides the basic necessities for the safe operation of a balloon flight without the weight and the expense of the current CSBF telemetry support packages. This paper will explain more about CSBF operations and delve further into the MIP development, testing and capabilities.
Fresiello, Libera; Khir, Ashraf W; Di Molfetta, Arianna; Kozarski, Maciej; Ferrari, Gianfranco
2013-11-01
The aim of this study was to investigate the effects of the intra aortic balloon pump (IABP) and of aortic compliance on left ventricular performance, including the effects of baroreflex control. The study was conducted using a hybrid cardiovascular simulator, including a computational cardiovascular sub-model, a hydraulic sub-model of the descending aorta, and a baroreflex computational sub-model. A 40 cc balloon was inserted into a rubber tube component of the hydraulic sub-model. A comparative analysis was conducted for two aortic compliances (C1 = 2.4 and C2 = 1.43 cm3/mmHg, corresponding to an aortic pulse pressure of 23 mmHg and 35 mmHg, respectively), driving the balloon for different trigger timings. Under C1 conditions, the IABP induced higher effects on baroreflex activity (decrement of sympathetic efferent activity: 10% for C1 and 14.7% for C2) and ventricular performance (increment of cardiac output (CO): 3.7% for C1 and 5.2% for C2, increment of endocardial viability ratio (EVR): 24.8% for C1 and 55% for C2). The best balloon timing was different for C1 and C2: inflation trigger timing (from the dicrotic notch) -0.09 s for C1 and -0.04 s for C2, inflation duration 0.25 s for C1 and 0.2 s for C2. Early inflation ensures better EVR, CO, and an increment of the afferent nerve activity, hence causing peripheral resistance and heart rate to decrease. The best balloon timing depends on aortic compliance, thus suggesting the need for a therapy tailored to the specific conditions of individual patients.
Acute control of pulmonary regurgitation with a balloon "valve". An experimental investigation.
Siwek, L G; Applebaum, R E; Jones, M; Clark, R E
1985-09-01
Operations for certain congenital cardiac lesions can produce pulmonary regurgitation. Pulmonary regurgitation contributes to right ventricular dysfunction, which may cause early postoperative morbidity and mortality. To ameliorate the problems of pulmonary regurgitation during the early postoperative period, we evaluated a method for its acute control. Complete pulmonary valvectomy was performed utilizing inflow occlusion in eight sheep. A catheter with a 15 ml spherical balloon was positioned in the pulmonary arterial trunk; its inflation and deflation were regulated by an intra-aortic balloon pump unit. Blood flow from the pulmonary arterial trunk and forward and regurgitant fraction were determined from electromagnetic flow transducer recordings. The regurgitant fraction with uncontrolled pulmonary regurgitation was 38% +/- 3% (forward flow = 42 +/- 5 ml/beat and regurgitant flow = 16 +/- 2 ml/beat). Inflation of the balloon during diastole was timed to completely eliminate pulmonary regurgitation. This balloon control of pulmonary regurgitation increased pulmonary arterial diastolic pressure from 12 +/- 1 to 17 +/- 1 mm Hg (p less than 0.0001) and decreased pulmonary arterial systolic pressure from 31 +/- 3 to 27 +/- 1 mm Hg (p = 0.06). Pulmonary arterial pulse pressure decreased from 19 +/- 3 to 9 +/- 1 mm Hg (p less than 0.003). Elimination of pulmonary regurgitation decreased right ventricular stroke volume (25 +/- 3 versus 42 +/- 5 ml/beat, p less than 0.0002) and resulted in a 46% reduction in right ventricular stroke work (5.0 +/- 0.6 versus 9.4 +/- 1.0 gm-m/beat, p less than 0.001) with no change in net forward pulmonary artery flow. Thus, acute pulmonary regurgitation can be controlled and this control improves overall hemodynamic status and decreases right ventricular work.
Evolution of NASA Scientific Ballooning and Particle Astrophysics Research
NASA Astrophysics Data System (ADS)
Jones, William Vernon
2017-01-01
Particle astrophysics research has a history in ballooning that spans over 100 years, ever since Victor Hess discovered cosmic rays on a manned balloon in 1912. The NASA Particle Astrophysics Program currently covers the origin, acceleration and transport of Galactic cosmic rays, plus the Nature of Dark Matter and Ultrahigh Energy Neutrinos. Progress in each of these topics has come from sophisticated instrumentation flown on Long Duration Balloon (LDB) flights around Antarctica for more than two decades. Super Pressure Balloons (SPB) and International Space Station (ISS) platforms are emerging opportunities that promise major steps forward for these and other objectives. NASA has continued development and qualification flights leading to SPB flights capable of supporting 1000 kg science instruments to 33 km for upwards of hundred day missions, with plans for increasing the altitude to 38 km. This goal is even more important now, in view of the Astro2010 Decadal Study recommendation that NASA should support Ultra-Long Duration Balloon (ULDB) flight development for studies of particle astrophysics, cosmology and indirect detection of dark matter. The mid-latitude test flight of an 18.8 MCF SPB launched from Wanaka, NZ in 2015 achieved 32 days of nearly constant altitude exposure, and an identical SPB launched from Wanaka in 2016 with a science payload flew for 46 days. Scientific ballooning as a vital infrastructure component for cosmic ray and general astrophysics investigations, including training for young scientists, graduate and undergraduate students, leading up to the 2020 Decadal Study and beyond, will be presented and discussed.
High-altitude wind prediction and measurement technology assessment
DOT National Transportation Integrated Search
2009-06-30
The principles and operational characteristics of balloon and radar-based techniques for measuring upper air winds in support of launches and recoveries are presented. Though either a balloon or radar system could serve as a standalone system, the sa...
Esrange Space Center, a Gate to Space
NASA Astrophysics Data System (ADS)
Widell, Ola
Swedish Space Corporation (SSC) is operating the Esrange Space Center in northern Sweden. Space operations have been performed for more than 40 years. We have a unique combination of maintaining balloon and rocket launch operations, and building payloads, providing space vehicles and service systems. Sub-orbital rocket flights with land recovery and short to long duration balloon flights up to weeks are offered. The geographical location, land recovery area and the long term experience makes Swedish Space Corporation and Esrange to an ideal gate for space activities. Stratospheric balloons are primarily used in supporting atmospheric research, validation of satellites and testing of space systems. Balloon operations have been carried out at Esrange since 1974. A large number of balloon flights are yearly launched in cooperation with CNES, France. Since 2005 NASA/CSBF and Esrange provide long duration balloon flights to North America. Flight durations up to 5 days with giant balloons (1.2 Million cubic metres) carrying heavy payload (up to 2500kg) with astronomical instruments has been performed. Balloons are also used as a crane for lifting space vehicles or parachute systems to be dropped and tested from high altitude. Many scientific groups both in US, Europe and Japan have indicated a great need of long duration balloon flights. Esrange will perform a technical polar circum balloon flight during the summer 2008 testing balloon systems and flight technique. We are also working on a permission giving us the opportunity on a circular stratospheric balloon flight around the North Pole.
The Latest Developments in NASA's Long Duration Balloon Systems
NASA Astrophysics Data System (ADS)
Stilwell, Bryan D.
The Latest Developments in NASA’s Long Duration Balloon Systems Bryan D. Stilwell, bryan.stilwell@csbf.nasa.gov Columbia Scientific Balloon Facility, Palestine, Texas, USA The Columbia Scientific Balloon Facility, located in Palestine, Texas offers the scientific community a high altitude balloon based communications platform. Scientific payload mass can exceed 2722 kg with balloon float altitudes on average of 40000 km and flight duration of up to 100 days. Many developments in electrical systems have occurred over the more than 25 years of long duration flights. This paper will discuss the latest developments in electronic systems related to long duration flights. Over the years, the long duration flights have increased in durations exceeding 56 days. In order to support these longer flights, the systems have had to increase in complexity and reliability. Several different systems that have been upgraded and/or enhanced will be discussed.
Yamashita, Kanefumi; Shiwaku, Hironari; Hirose, Ryuichiro; Kai, Hiroki; Nakashima, Ryo; Kato, Daisuke; Beppu, Richiko; Takeno, Shinsuke; Sasaki, Takamitsu; Nimura, Satoshi; Iwasaki, Akinori; Inoue, Haruhiro; Yamashita, Yuichi
2016-11-01
Achalasia is a primary motility disorder with incomplete lower esophageal sphincter relaxation; it has an annual incidence of 0.11 cases per 100 000 children. Peroral endoscopic myotomy (POEM) is a new endoscopic treatment method for achalasia. Reports about POEM in pediatric patients are rare. We herein report the case of a 9-year-old female patient with achalasia who underwent POEM. The patient underwent endoscopic balloon dilatation because medication was not effective at a previous hospital; however, endoscopic balloon dilatation was not effective either. She then underwent successful POEM upon admission at our hospital. The patient was symptom-free at 2 years postoperatively with no signs of esophagitis in the absence of proton-pump inhibitor therapy. © 2016 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
Balloon-borne photoionization mass spectrometer for measurement of stratospheric gases
NASA Technical Reports Server (NTRS)
Aikin, A. C.; Maier, E. J. R.
1978-01-01
A balloon-borne photoionization mass spectrometer used to measure stratospheric trace gases is described. Ions are created with photons from high-intensity krypton discharge lamps and a quadrupole mass analyzer is employed for ion identification. Differential pumping is achieved with liquid helium cryopumping. To insure measurement of unperturbed stratospheric air, the entire system is contained in a sealed gondola and the atmospheric sample is taken some distance away during descent. The photoionization technique allows the detection of a low ionization potential constituent, such as nitric oxide, at less than a part in one billion in the presence of the major atmospheric gases and their isotopes. Operation of the mass spectrometer system was demonstrated during a daytime flight from Palestine, Texas on 26 April 1977. The sensitivity achieved and the unique selectivity afforded by this technique offer a capability for trace constituent measurement not possible with the more conventional electron impact ionization approach.
Konishi, Takao; Funayama, Naohiro; Yamamoto, Tadashi; Nishihara, Hiroshi; Hotta, Daisuke; Kikuchi, Kenjiro; Yokoyama, Hideo; Ohori, Katsumi
2016-06-06
Left ventricular wall rupture remains a major lethal complication of acute myocardial infarction and hypertension is a well-known predisposing factor of cardiac rupture after myocardial infarction. An 87-year-old man was admitted to our hospital, diagnosed as acute myocardial infarction (AMI). The echocardiogram showed 0.67-cm(2) aortic valve, consistent with severe aortic stenosis (AS). A coronary angiography showed a chronic occlusion of the proximal left circumflex artery and a 99 % stenosis and thrombus in the mid right coronary artery. During percutaneous angioplasty of the latter, transient hypotension and bradycardia developed at the time of balloon inflation, and low doses of noradrenaline and etilefrine were intravenously administered as needed. The patient suddenly lost consciousness and developed electro-mechanical dissociation. Cardio-pulmonary resuscitation followed by insertion of an intra-aortic balloon pump (IABP) and percutaneous cardiopulmonary support were initiated. The echocardiogram revealed moderate pericardial effusion, though the site of free wall rupture was not distinctly visible. A left ventriculogram clearly showed an infero-posterior apical wall rupture. Surgical treatment was withheld because of the interim development of brain death. In this patient, who presented with severe AS, the administration of catecholamine to stabilize the blood pressure probably increased the intraventricular pressures considerably despite apparently normal measurements of the central aortic pressure. IABP, temporary pacemaker, or both are recommended instead of intravenous catecholamines for patients with AMI complicated with significant AS to stabilize hemodynamic function during angioplasty.
Amaral Gonçalves Fusatto, Helena; Castilho de Figueiredo, Luciana; Ragonete Dos Anjos Agostini, Ana Paula; Sibinelli, Melissa; Dragosavac, Desanka
2018-01-01
The aim of this study was to identify pulmonary dysfunction and factors associated with prolonged mechanical ventilation, hospital stay, weaning failure and mortality in patients undergoing coronary artery bypass grafting with use of intra-aortic balloon pump (IABP). This observational study analyzed respiratory, surgical, clinical and demographic variables and related them to outcomes. We analyzed 39 patients with a mean age of 61.2 years. Pulmonary dysfunction, characterized by mildly impaired gas exchange, was present from the immediate postoperative period to the third postoperative day. Mechanical ventilation time was influenced by the use of IABP and PaO2/FiO2, female gender and smoking. Intensive care unit (ICU) stay was influenced by APACHE II score and use of IABP. Mortality was strongly influenced by APACHE II score, followed by weaning failure. Pulmonary dysfunction was present from the first to the third postoperative day. Mechanical ventilation time was influenced by female gender, smoking, duration of IABP use and PaO2/FiO2 on the first postoperative day. ICU stay was influenced by APACHE II score and duration of IABP. Mortality was influenced by APACHE II score, followed by weaning failure. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Testuz, Ariane; Roffi, Marco; Bonvini, Robert Francis
2013-03-01
This case aims to describe the hemodynamic effects of intra-aortic balloon pump (IABP) in patients with ventricular septal defect (VSD) complicating myocardial infarction (MI). A 79-year-old man with no previous cardiovascular history presented to the emergency department with subacute inferior myocardial infarction associated with mild signs of systemic hypoperfusion. A transthoracic echocardiography revealed a large akinesia of the left ventricular inferior wall with preserved global left ventricular ejection fraction, as well as a large VSD in the midinferior portion of the interventricular septum. Coronary angiography showed an occlusion of the mid portion of a dominant circumflex coronary artery. The invasive hemodynamic evaluation showed a sizable left-to-right shunt (Q(p)/Q(s) = 3.1). Activation of the IABP led to an immediate reduction of the shunt (Q(p)/Q(s) = 2.4 = 22% reduction), an increase in systemic cardiac output (from 2.1 L/min to 2.4 L/min = +12%) and a decrease in the systemic vascular resistances (from 2240 to 1920 dyne-sec/cm(5) = 15% reduction). In patients with post-MI VSD, placement of IABP leads to an immediate reduction in left-to-right shunt and as a consequence to an increase in systemic cardiac output, which may allow hemodynamic stabilization of the patient prior to surgical VSD closure. Copyright © 2012 Wiley Periodicals, Inc.
A hard X-ray experiment for long-duration balloon flights
NASA Astrophysics Data System (ADS)
Johnson, W. N.; Kurfess, J. D.; Strickman, M. S.; Saulnier, D. M.
The Naval Research Lab has developed a balloon-borne hard X-ray experiment which is designed for 60- to 90-day flight durations soon to be available with around the world Sky Anchor or RACOON balloon flights. The experiment's scintillation detector is sensitive to the 15 - 250 keV X-ray energy range. The experiment includes three microcomputer systems which control the data acquisition and provide the orientation and navigation information required for global balloon flights. The data system supports global data communications utilizing the GOES satellite as well as high bit rate communications through L-band li line-of-site transmissions
Sensitometric crossover for 2485 in balloon observation astronomical program
NASA Technical Reports Server (NTRS)
Perry, L.
1973-01-01
Photographic film processing support is described for the CREPE 4 project, a high-altitude balloon study of cosmic radiation. The processing procedures are summarized, and recommendations are made for the size and thickness of film to be used in future projects.
Status report on the activities of National Balloon Facility at Hyderabad
NASA Astrophysics Data System (ADS)
Shankarnarayan, Sreenivasan; S, Sreenivasan; Shankarnarayan, Sreenivasan; Manchanda, R. K.; Subba Rao Jonnalagadda, Venkata; Buduru, Suneelkumar
National balloon facility at Hyderabad has been mandated to provide launch support for Indian and International scientific balloon experiments and also perform the necessary research and development in the design and fabrication of plastic balloons. In the last 4 years, since our last report, NBF has launched many successful balloon flights for the astronomy payloads and a large number of high altitude GPS Sonde flights at different places in the country. We have also continued our efforts on qualification of raw materials for zero-failure performance of our balloons and major focus on upgrading of various facilities and load-line instrumentation for launching from remote sites. We foresee a surge of balloon based experimental activity for in-situ measurements in atmospheric sciences and concept validation payloads for future space based instruments. A new centre for research in Environmental Sciences and Payload Engineering (ESPE) has also been set up at the National Balloon Facility campus to develop and conduct research in various aspects of Environmental sciences in collaboration with other groups, with a specific goal to identify, development of advanced technologies leading to an improved understanding of the earth system. The Payload Engineering facility is geared to the Design and Fabrication of Micro and Nano Satellites and will act as Inter -University Centre for payload fabrication. In this paper we present an overview of the present and planned activities in scientific ballooning at National Balloon Facility Hyderabad.
Near Space Lab-Rat Experimentation using Stratospheric Balloon
NASA Astrophysics Data System (ADS)
Buduru, Suneel Kumar; Reddy Vizapur, Anmi; Rao Tanneeru, Venkateswara; Trivedi, Dharmesh; Devarajan, Anand; Pandit Manikrao Kulkarni, MR..; Ojha, Devendra; Korra, Sakram; Neerudu, Nagendra; Seng, Lim; Godi, Stalin Peter
2016-07-01
First ever balloon borne lab-rat experiment up to near space stratospheric altitude levels carried out at TIFR Balloon Facility, Hydeabad using zero pressure balloons for the purpose of validating the life support system. A series of two balloon experiments conducted under joint collaboration with IN.Genius, Singapore in the year 2015. In these experiments, three lab-rats sent to stratosphere in a pressurized capsule designed to reach an altitude of 30 km by keeping constant pressure, temperature and maintained at a precise rate of oxygen supply inside the capsule. The first experiment conducted on 1 ^{st} February, 2015 with a total suspended weight of 225 kg. During the balloon ascent stage at 18 km altitude, sensors inside the capsule reported drastic drop in internal pressure while oxygen and temperatures maintained at correct levels resulted in premature fligt termination at 20.1 km. All the three lab-rats recovered without life due to the collapse of their lungs caused by the depressurization inside the capsule. The second experiment conducted on 14th March, 2015 using a newly developed capsule with rectification of depressurization fault by using improved sealing gaskets and hermitically sealed connectors for sending lab-rats again to stratosphere comprising a total suspended load of 122.3 kg. The balloon flight was terminated after reaching 29.5 km in 110 minutes and succesfully recovered all the three lab-rats alive. This paper focuses on lessons learnt of the development of the life support system as an integral pressurized vessel, flight control instrumentation, flight simulation tests using thermo-vaccum chamber with pre-flight operations.
NASA Astrophysics Data System (ADS)
Dimiduk, D.; Caylor, M.; Williamson, D.; Larson, L.
1995-01-01
The High Altitude Balloon Experiment demonstration of Acquisition, Tracking, and Pointing (HABE-ATP) is a system built around balloon-borne payload which is carried to a nominal 26-km altitude. The goal is laser tracking thrusting theater and strategic missiles, and then pointing a surrogate laser weapon beam, with performance levels end a timeline traceable to operational laser weapon system requirements. This goal leads to an experiment system design which combines hardware from many technology areas: an optical telescope and IR sensors; an advanced angular inertial reference; a flexible multi-level of actuation digital control system; digital tracking processors which incorporate real-time image analysis and a pulsed, diode-pumped solid state tracking laser. The system components have been selected to meet the overall experiment goals of tracking unmodified boosters at 50- 200 km range. The ATP system on HABE must stabilize and control a relative line of sight between the platform and the unmodified target booster to a 1 microrad accuracy. The angular pointing reference system supports both open loop and closed loop track modes; GPS provides absolute position reference. The control system which positions the line of sight for the ATP system must sequence through accepting a state vector handoff, closed-loop passive IR acquisition, passive IR intermediate fine track, active fine track, and then finally aimpoint determination and maintenance modes. Line of sight stabilization to fine accuracy levels is accomplished by actuating wide bandwidth fast steering mirrors (FSM's). These control loops off-load large-amplitude errors to the outer gimbal in order to remain within the limited angular throw of the FSM's. The SWIR acquisition and MWIR intermediate fine track sensors (both PtSi focal planes) image the signature of the rocket plume. After Hard Body Handover (HBHO), active fine tracking is conducted with a visible focal plane viewing the laser-illuminated target rocket body. The track and fire control performance must be developed to the point that an aimpoint can be selected, maintained, and then track performance scored with a low-power 'surrogate' weapon beam. Extensive instrumentation monitors not only the optical sensors and the video data, but all aspects of each of the experiment subsystems such as the control system, the experiment flight vehicle, and the tracker. Because the system is balloon-borne and recoverable, it is expected to fly many times during its development program.
Balloon Support Systems Performance for the Cosmic Rays Energetics and Mass Mission
NASA Technical Reports Server (NTRS)
Tompson, Linda D.; Stuchlik, David W.
2006-01-01
The Ballooncraft Support Systems were developed by NASA Wallops Flight Facility for use on ULDB class balloon missions. The support systems have now flown two missions supporting the Cosmic Rays Energetics and Mass (CREAM) experiment. The first, CREAM I, flown in December 2004, was for a record breaking 41 days, 21 hours, and the second, flown in December 2005, was for 28 days, 9 hours. These support systems provide CREAM with power, telecommunications, command and data handling ioc!uding Plight computers, mechanical structures, thermal management and attitude control to help ensure a successful scientific mission. This paper will address the performance and success of these support systems over the two missions.
Chakravarthy, Murali; Prabhakumar, Dattatreya; Thimmannagowda, Patil; Krishnamoorthy, Jayaprakash; George, Antony; Jawali, Vivek
2017-01-01
While off pump coronary artery bypass surgery is practiced with an intention to reduce the morbidity associated with cardiopulmonary bypass, the resultant 'hypercoagulability' needs to be addressed. Complications such as cavitary thrombus possibly due to the hyper coagulability after off pump coronary artery bypass surgery have been described. Many clinicians use higher doses of heparin - up to 5 mg/kg in order to thwart this fear. Overall, there appears to be no consensus on the dose of heparin in off pump coronary artery bypass surgeries. The aim of the study was understand the differences in outcome of such as transfusion requirement, myocardial ischemia, and morbidity when two different doses were used for systemic heparinization. Elective patients scheduled for off pump coronary artery bypass surgery were included. Ongoing anti platelet medication was not an exclusion criteria, however, anti platelet medications were ceased about a week prior to surgery when possible. Thoracic epidural anesthesia was administered as an adjunct in patients who qualified for it. By computer generated randomization chart, patients were chosen to receive either 2 or 3 mg/kg of intravenous unfractioned heparin to achieve systemic heparinization with activated clotting time targeted at >240 secs. Intraoperative blood loss, postoperative blood loss, myocardial ischemic episodes, requirement of intraaortic balloon counter pulsation and transfusion requirement were analyzed. Sixty two patients participated in the study. There was one conversion to cardiopulmonary bypass. The groups had comparable ACT at baseline (138.8 vs. 146.64 seconds, P = 0.12); 3 mg/kg group had significantly higher values after heparin, as expected. But after reversal with protamine, ACT and need for additional protamine was similar among the groups. Intraoperative (685.56 ± 241.42 ml vs. 675.15 ± 251.86 ml, P = 0.82) and postoperative blood loss (1906.29 ± 611.87 ml vs 1793.65 ± 663.54 ml , p value 0.49) were similar among the groups [Table 4]. The incidence of ECG changes of ischemia, arrhythmias, conversion to CPB, or need for intra-aortic balloon counter pulsation were not different. Use of either 2 or 3 mg/kg heparin for systemic heparinization in patients undergoing OPCAB did not affect the outcome.
Mishra, Manisha; Malhotra, Rajneesh; Mishra, Anil; Meharwal, Zile Singh; Trehan, Naresh
2002-12-01
To evaluate the hemodynamic alterations during off-pump coronary artery bypass graft surgery to determine the degree of impairment caused and the techniques to rectify them. Prospective, observational cohort study performed from January 2000 through September 2000. Patients (n = 500) with coronary artery disease undergoing multivessel off-pump coronary artery bypass graft surgery using the Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, MN). Unstable patients with ongoing ischemia were excluded from the study. All patients were monitored with radial artery and pulmonary artery catheters and continuous transesophageal echocardiography monitoring with a multiplane transducer. The perioperative requirement of an intracoronary shunt, inotropes, or an intra-aortic balloon pump was noted. The effect of the Trendelenburg position and fluids on hemodynamics was observed. The need for defibrillation and institution of emergency cardiopulmonary bypass were major endpoints to determine the inability of the patient to tolerate displacement of the heart. Mean patient age was 59.3 +/- 11.6 years. There were 204 (40%) patients in the high-risk category; 54 (10.8%) patients had left ventricular ejection fraction <25%. The mean number of grafts was 2.7 +/- 0.8. Vertical displacement of the heart to access the lateral and inferior walls decreased the mean arterial pressure by 18 +/- 4% (p < 0.01), with a concomitant increase in central venous pressure of 66 +/- 18% (p < 0.001). The stroke volume and the cardiac index were reduced by 35.7 +/- 11% (p < 0.001) and 45 +/- 13% (p < 0.001). On transesophageal echocardiography, there was development of new regional wall motion abnormalities in 59.2% and a decrease in global left ventricular functions in 61.2%. The use of inotropes was highest during anastomosis on the posterior wall-78.4% compared with 21.9% for the anterior wall. An intra-aortic balloon pump was used in 55 (11.2%) patients, and 7 (0.71 %) patients had to be put on emergency CPB. The in-hospital mortality was 1.2%. Most patients had hemodynamic changes easily correctable by fluids and inotropes. Monitoring of left ventricular and right ventricular function by transesophageal echocardiography enhances safety of the procedure and is recommended. The use of the Octopus II tissue stabilizer proved to be a safe and versatile means to stabilize the heart during off-pump coronary artery bypass procedures, especially in high-risk patients. Copyright 2002, Elsevier Science (USA). All rights reserved.
NASA Technical Reports Server (NTRS)
Said, Magdi A; Schur, Willi W.; Gupta, Amit; Mock, Gary N.; Seyam, Abdelfattah M.; Theyson, Thomas
2004-01-01
Science and technology development from balloon-borne telescopes and experiments is a rich return on a relatively modest involvement of NASA resources. For the past three decades, the development of increasingly competitive and complex science payloads and observational programs from high altitude balloon-borne platforms has yielded significant scientific discoveries. The success and capabilities of scientific balloons are closely related to advancements in the textile and plastic industries. This paper will present an overview of scientific balloons as a viable and economical platform for transporting large telescopes and scientific instruments to the upper atmosphere to conduct scientific missions. Additionally, the paper sheds the light on the problems associated with UV degradation of high performance textile components that are used to support the payload of the balloon and proposes future research to reduce/eliminate Ultra Violet (UV) degradation in order to conduct long-term scientific missions.
Diurnal forcing of planetary atmospheres
NASA Technical Reports Server (NTRS)
Houben, Howard C.
1991-01-01
The utility of the Mars Planetary Boundary Layer Model (MPBL) for calculations in support of the Mars 94 balloon mission was substantially enhanced by the introduction of a balloon equation of motion into the model. Both vertical and horizontal excursions of the balloon are calculated along with its volume, temperature, and pressure. The simulations reproduce the expected 5-min vertical oscillations of a constant density balloon at altitude on Mars. The results of these calculations are presented for the nominal target location of the balloon. A nonlinear balanced model was developed for the Martian atmosphere. It was used to initialize a primitive equation model for the simulations of the Earth's atmosphere at the time of the El Chichon eruption in 1982. It is also used as an assimilation model to update the temperature and wind fields at frequent intervals.
Astrobiology Exploration Strategies for the Mars Polar Regions Using Balloon Platforms
NASA Technical Reports Server (NTRS)
Mahaffy, P. R.; Atreya, S. A.; Fairbrother, D. A.; Farrell, W. M.; Gorevan, S.; Jones, J.; Mitrofanov, I.; Scott, J.
2003-01-01
Montgolfiere balloons can provide a unique near-surface platform for an extended traverse over the polar regions of Mars. During the polar summer, such solar powered balloons would remain in the constant sun of the polar summer and could remain airborne for many weeks or even months as the atmospheric circulation would drive the balloons around the polar region many times before the balloon would cross the terminator. Such a platform for scientific measurements could provide in situ sampling of the atmosphere for trace disequilibrium species that might be indicators of present geological or biological activity in this region. It could furthermore provide high resolution imaging, deep electromagnetic (EM) sounding for subsurface stratigraphy and liquid water, and high spatial resolution neutron measurements of subsurface ice. Technologies for robust balloon deployment on entry and controlled encounters with the surface and near subsurface for sample acquisition in otherwise inaccessible regions are presently being studied and developed with support from NASA.
Astrobiology Exploration Strategies for the Mars Polar Regions Using Balloon Platforms
NASA Technical Reports Server (NTRS)
Mahaffy, P. R.; Atreya, S. A.; Fairbrother, D. A.; Farrell, W. M.; Gorevan, S.; Jones, J.; Mitrofanov, I.; Scott, J.
2003-01-01
Montgolfiere balloons can provide a unique near-surface platform for an extended traverse over the polar regions of Mars. During the polar summer, such solar powered balloons would remain in the constant sun of the polar summer and could remain airborne for many weeks or even months as the atmospheric circulation would drive the balloons around the polar region many times before the balloon would cross the terminator. Such a platform for scientific measurements could provide in situ sampling of the atmosphere for trace disequilibrium species that might be indicators of present geological or biological activity in this regon. It could furthermore provide high resolution imaging, deep electromagnetic (EM) sounding for subsurface stratigraphy and liquid water, and high spatial resolution neutron measurements of subsurface ice. Technologies for robust balloon deployment on entry and controlled encounters with the surface and near subsurface for sample acquisition in otherwise inaccessible regions are presently being studied and developed with support from NASA.
Advancements in mechanical circulatory support for patients in acute and chronic heart failure
Csepe, Thomas A.
2017-01-01
Cardiogenic shock (CS) continues to have high mortality and morbidity despite advances in pharmacological, mechanical, and reperfusion approaches to treatment. When CS is refractory to medical therapy, percutaneous mechanical circulatory support (MCS) should be considered. Acute MCS devices, ranging from intra-aortic balloon pumps (IABPs) to percutaneous temporary ventricular assist devices (VAD) to extracorporeal membrane oxygenation (ECMO), can aid, restore, or maintain appropriate tissue perfusion before the development of irreversible end-organ damage. Technology has improved patient survival to recovery from CS, but in patients whom cardiac recovery does not occur, acute MCS can be effectively utilized as a bridge to long-term MCS devices and/or heart transplantation. Heart transplantation has been limited by donor heart availability, leading to a greater role of left ventricular assist device (LVAD) support. In patients with biventricular failure that are ineligible for LVAD implantation, further advancements in the total artificial heart (TAH) may allow for improved survival compared to medical therapy alone. In this review, we discuss the current state of acute and durable MCS, ongoing advances in LVADs and TAH devices, improved methods of durable MCS implantation and patient selection, and future MCS developments in this dynamic field that may allow for optimization of HF treatment. PMID:29268418
Seth, Ashok; Gupta, Sajal; Pratap Singh, Vivudh; Kumar, Vijay
2017-09-01
Final stent dimensions remain an important predictor of restenosis, target vessel revascularisation (TVR) and subacute stent thrombosis (ST), even in the drug-eluting stent (DES) era. Stent balloons are usually semi-compliant and thus even high-pressure inflation may not achieve uniform or optimal stent expansion. Post-dilatation with non-compliant (NC) balloons after stent deployment has been shown to enhance stent expansion and could reduce TVR and ST. Based on supporting evidence and in the absence of large prospective randomised outcome-based trials, post-dilatation with an NC balloon to achieve optimal stent expansion and maximal luminal area is a logical technical recommendation, particularly in complex lesion subsets.
A servo-controlled canine model of stable severe ischemic left ventricular failure.
Wagner, Richard L; Hood, William B; Howland, Peter A
2009-12-01
Reversible left ventricular failure was produced in conscious dogs by compromise of the coronary circulation. In animals with prior left anterior descending coronary artery occlusion, mean left atrial pressure (LAP) was incorporated into an automatic feedback control system used to inflate a balloon cuff on the circumflex (Cfx) coronary artery. The system could produce stable increases in LAP to 15-20 mm Hg. The dominating system transfer function was the ratio of LAP to balloon volume (BV), which was characterized by a fixed delay (5 s), with LAP/BV = (8e(-jomegatau ))/(0.02 + jomega). The system was stabilized by a phase lead network to reduce oscillations of LAP. A total of seven experiments were conducted in three dogs, and testing of inotropic agents was possible in three experiments under stable conditions with the pump off after an hour or more of operation. Problems encountered were 0.003-0.008 Hz oscillations in LAP in three experiments, which could usually be controlled by reducing the system gain. Late stage ventricular fibrillation occurred in all three animals, but defibrillation was easily accomplished after deflating the Cfx balloon. This system produces reversible left ventricular failure solely due to ischemia, thus closely simulating clinical heart failure due to coronary insufficiency.
Middle atmospheric electric fields over thunderstorms
NASA Technical Reports Server (NTRS)
Holzworth, Robert H.
1992-01-01
This grant has supported a variety of investigations all having to do with the external electrodynamics of thunderstorms. The grant was a continuation of work begun while the PI was at the Aerospace Corporation (under NASA Grant NAS6-3109) and the general line of investigation continues today under NASA Grants NAG5-685 and NAG6-111. This report will briefly identify the subject areas of the research and associated results. The period actually covered by the grant NAG5-604 included the following analysis and flights: (1) analysis of five successful balloon flights in 1980 and 1981 (under the predecessor NASA grant) in the stratosphere over thunderstorms; (2) development and flight of the Hy-wire tethered balloon system for direct measurement of the atmospheric potential to 250 kV (this involved multiple tethered balloon flight periods from 1981 through 1986 from several locations including Wallops Island, VA, Poker Flat and Ft. Greely, AK and Holloman AFB, NM.); (3) balloon flights in the stratosphere over thunderstorms to measure vector electric fields and associated parameters in 1986 (2 flights), 1987 (4 flights), and 1988 (2 flights); and (4) rocket-borne optical lightning flash detectors on two rocket flights (1987 and 1988) (the same detector design that was used for the balloon flights listed under #3). In summary this grant supported 8 stratospheric zero-pressure balloon flights, tethered aerostat flights every year between 1982-1985, instruments on 2 rockets, and analysis of data from 6 stratospheric flights in 1980/81.
Tight swimming trunks to prevent post scrotal surgery: an experimental justification.
Al-Abed, Yahya A; Carr, Thomas W
2013-01-01
To conduct a study to measure the pressure effects of the different scrotal supports applied on a simulated expanding scrotal hematoma. We created a model of an expanding hematoma with simultaneous pressure recording using a urodynamics system. Pressures were recorded independently first without application of any support. Then, three types of scrotal supports were tested, including Euron Net Knickers, scrotal suspensory bandage, and tight swimming trunks brand Speedo® brief and shorts. Subsequent pressures were recorded using the model created, which was applied inside the supports worn by two male volunteers A and B. Without any external compression, the pressure inside the simulated expanding hematoma "balloon" reached a maximum of 15 cmH2O. The pressures measured whilst wearing "Netelast knickers" in both subjects A and B reached a maximum of 15 cmH2O suggesting that this garment exerted no measurable compression. The suspensory scrotal support was then tested in both subjects. As the balloon started to fill with saline, the simulated hematoma pushed the scrotal support forward resulting in falling of the balloon outside the scrotal support. Subsequently, Speedo® briefs and shorts were tested. With Speedo® briefs, maximum filling pressures of 49 cmH2O and 40 cmH2O were reached in subjects A and B, respectively. When using Speedo® shorts, however, maximum pressures of 55 cmH2O in subject A and 54 cmH2O in subject B were reached at the end of the balloon filling to 300 mL of saline. The use of tight swimming trunks (Speedo®) has led to satisfactory results in the prevention of hematoma post scrotal surgery.
Stratospheric Balloon Platforms for Near Space Access
NASA Astrophysics Data System (ADS)
Dewey, R. G.
2012-12-01
For over five decades, high altitude aerospace balloon platforms have provided a unique vantage point for space and geophysical research by exposing scientific instrument packages and experiments to space-like conditions above 99% of Earth's atmosphere. Reaching altitudes in excess of 30 km for durations ranging from hours to weeks, high altitude balloons offer longer flight durations than both traditional sounding rockets and emerging suborbital reusable launch vehicles. For instruments and experiments requiring access to high altitudes, engineered balloon systems provide a timely, responsive, flexible, and cost-effective vehicle for reaching near space conditions. Moreover, high altitude balloon platforms serve as an early means of testing and validating hardware bound for suborbital or orbital space without imposing space vehicle qualifications and certification requirements on hardware in development. From float altitudes above 30 km visible obscuration of the sky is greatly reduced and telescopes and other sensors function in an orbit-like environment, but in 1g. Down-facing sensors can take long-exposure atmospheric measurements and images of Earth's surface from oblique and nadir perspectives. Payload support subsystems such as telemetry equipment and command, control, and communication (C3) interfaces can also be tested and operationally verified in this space-analog environment. For scientific payloads requiring over-flight of specific areas of interests, such as an active volcano or forest region, advanced mission planning software allows flight trajectories to be accurately modeled. Using both line-of-sight and satellite-based communication systems, payloads can be tracked and controlled throughout the entire mission duration. Under NASA's Flight Opportunities Program, NSC can provide a range of high altitude flight options to support space and geophysical research: High Altitude Shuttle System (HASS) - A balloon-borne semi-autonomous glider carries payloads to high altitude and returns them safely to pre-selected landing sites, supporting quick recovery, refurbishment, and re-flight. Small Balloon System (SBS) - Controls payload interfaces via a standardized avionics system. Using a parachute for recovery, the SBS is well suited for small satellite and spacecraft subsystem developers wanting to raise their Technology Readiness Level (TRL) in an operationally relevant environment. Provides flexibility for scientific payloads requiring externally mounted equipment, such as telescopes and antennas. Nano Balloon System (NBS) - For smaller payloads (~CubeSats) with minimal C3 requirements, the Nano Balloon System (NBS) operates under less restrictive flight regulations with increased operational flexibility. The NBS is well suited for payload providers seeking a quick, simple, and cost effective solution for operating small ~passive payloads in near space. High altitude balloon systems offer the payload provider and experimenter a unique and flexible platform for geophysical and space research. Though new launch vehicles continue to expand access to suborbital and orbital space, recent improvements in high altitude balloon technology and operations provide a cost effective alternative to access space-like conditions.
Correlation of the tokamak H-mode density limit with ballooning stability at the separatrix
NASA Astrophysics Data System (ADS)
Eich, T.; Goldston, R. J.; Kallenbach, A.; Sieglin, B.; Sun, H. J.; ASDEX Upgrade Team; Contributors, JET
2018-03-01
We show for JET and ASDEX Upgrade, based on Thomson-scattering measurements, a clear correlation of the density limit of the tokamak H-mode high-confinement regime with the approach to the ideal ballooning instability threshold at the periphery of the plasma. It is shown that the MHD ballooning parameter at the separatrix position α_sep increases about linearly with the separatrix density normalized to Greenwald density, n_e, sep/n_GW for a wide range of discharge parameters in both devices. The observed operational space is found to reach at maximum n_e, sep/n_GW≈ 0.4 -0.5 at values for α_sep≈ 2 -2.5, in the range of theoretical predictions for ballooning instability. This work supports the hypothesis that the H-mode density limit may be set by ballooning stability at the separatrix.
Innovative measurement within the atmosphere of Venus.
NASA Astrophysics Data System (ADS)
Ekonomov, Alexey; Linkin, Vyacheslav; Manukin, Anatoly; Makarov, Vladislav; Lipatov, Alexander
The results of Vega project experiments with two balloons flew in the cloud layer of the atmosphere of Venus are analyzed as to the superrotation nature and local dynamic and thermodynamic characteristics of the atmosphere. These balloons in conjunction with measurements of temperature profiles defined by the Fourier spectrometer measurements from the spacecraft Venera 15 allow us to offer a mechanism accelerating the atmosphere to high zonal velocities and supporting these speeds, the atmosphere superrotation in general. Spectral measurements with balloons confirm the possibility of imaging the planet's surface from a height of not more than 55 km. Promising experiments with balloons in the atmosphere of Venus are considered. In particular, we discuss the possibility of measuring the geopotential height, as Venus no seas and oceans to vertical positioning of the temperature profiles. As an innovative research facilities within the atmosphere overpressure balloon with a lifetime longer than 14 Earth days and vertical profile microprobes are considered.
Usefulness of Corsair microcatheter to cross stent struts in bifurcation lesions.
Fujimoto, Yoshihide; Iwata, Yo; Yamamoto, Masashi; Kobayashi, Yoshio
2014-01-01
Side branch compromise after stenting in bifurcation lesions is a matter of concern. It may happen that even low-profile balloon catheters do not cross stent struts after rewiring. The Corsair catheter is a hybrid catheter that has features of a microcatheter and a support catheter. The present study evaluated usefulness of the Corsair catheter to facilitate advancing a low-profile balloon catheter through stent struts in bifurcation lesions. After rewiring, low-profile balloon catheters failed to cross stent struts of 29 bifurcation lesions. The Corsair microcatheter successfully crossed stent struts in all lesions except one (97 %) where a stent was implanted to treat in-stent restenosis (stent-in-stent). Low-profile balloon catheters were able to advance into the side branch of all bifurcation lesions where the Corsair microcatheter crossed stent struts. In conclusion, the Corsair microcatheter may be utilized if low-profile balloon catheters are unable to cross stent struts in bifurcation lesions.
Benedetto, Umberto; Caputo, Massimo; Vohra, Hunaid; Davies, Alan; Hillier, James; Bryan, Alan; Angelini, Gianni D
2016-11-01
We conducted a single-center analysis on short-term outcomes and long-term survival in actively treated diabetic patients undergoing off-pump coronary artery bypass versus on-pump coronary artery bypass surgery. The final population consisted of 2450 patients with actively treated diabetes (mean age, 66 ± 9 years; female/male 545/1905, 22%). Of those, 1493 subjects were orally treated and 1011 subjects were taking insulin. Off-pump coronary artery bypass and on-pump coronary artery bypass were performed in 1253 and 1197 patients, respectively. Propensity score matching was used to compare the 2 matched groups. When compared with on-pump coronary artery bypass, off-pump coronary artery bypass was associated with a significant risk reduction for postoperative cerebrovascular accident (odds ratio, 0.49; 95% confidence interval [CI], 0.25-0.99; P = .04), need for postoperative intra-aortic balloon pump (odds ratio, 0.48; 95% CI, 0.30-0.77; P = .002), and reexploration for bleeding (odds ratio, 0.55; 95% CI, 0.33-0.94; P = .02). Off-pump coronary artery bypass did not significantly affect early (hazard ratio [HR], 1.32; 95% CI, 0.73-2.40; P = .36) and late (HR, 1.08; 95% CI, 0.92-1.28; P = .32) mortality. However, off-pump coronary artery bypass with incomplete revascularization was associated with reduced survival when compared with off-pump coronary artery bypass with complete revascularization (HR, 1.82; 95% CI, 1.34-2.46; P = .0002) and on-pump coronary artery bypass with complete revascularization (HR, 1.83; 95% CI, 1.36-2.47; P < .0001). Off-pump coronary artery bypass is a safe and feasible option for diabetic patients with multivessel disease, reduces the incidence of early complications including postoperative cerebrovascular events, and provides excellent long-term survival similar to on-pump coronary artery bypass surgery in case of complete revascularization. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Novel method for dynamic control of intracranial pressure.
Luciano, Mark G; Dombrowski, Stephen M; Qvarlander, Sara; El-Khoury, Serge; Yang, Jun; Thyagaraj, Suraj; Loth, Francis
2017-05-01
OBJECT Intracranial pressure (ICP) pulsations are generally considered a passive result of the pulsatility of blood flow. Active experimental modification of ICP pulsations would allow investigation of potential active effects on blood and CSF flow and potentially create a new platform for the treatment of acute and chronic low blood flow states as well as a method of CSF substance clearance and delivery. This study presents a novel method and device for altering the ICP waveform via cardiac-gated volume changes. METHODS The novel device used in this experiment (named Cadence) consists of a small air-filled inelastic balloon (approximately 1.0 ml) implanted into the intracranial space and connected to an external programmable pump, triggered by an R-wave detector. Balloons were implanted into the epidural space above 1 of the hemispheres of 19 canines for up to 10 hours. When activated, the balloons were programed to cyclically inflate with the cardiac cycle with variable delay, phase, and volume. The ICP response was measured in both hemispheres. Additionally, cerebral blood flow (heat diffusion and laser Doppler) was studied in 16 canines. RESULTS This system, depending on the inflation pattern of the balloon, allowed a flattening of the ICP waveform, increase in the ICP waveform amplitude, or phase shift of the wave. This occurred with small mean ICP changes, typically around ± 2 mm Hg (15%). Bilateral ICP effects were observed with activation of the device: balloon inflation at each systole increased the systolic ICP pulse (up to 16 mm Hg, 1200%) and deflation at systole decreased or even inverted the systolic ICP pulse (-0.5 to -19 mm Hg, -5% to -1600%) in a dose-(balloon volume) dependent fashion. No aphysiological or deleterious effects on systemic pressure (≤ ±10 mm Hg; 13% change in mean pressure) or cardiac rate (≤ ± 17 beats per minute; 16% change) were observed during up to 4 hours of balloon activity. CONCLUSIONS The results of these initial studies using an intracranially implanted, cardiac-gated, volume-oscillating balloon suggest the Cadence device can be used to modify ICP pulsations, without physiologically deleterious effects on mean ICP, systemic vascular effects, or brain injury. This device and technique may be used to study the role of ICP pulsatility in intracranial hemo- and hydrodynamic processes and introduces the creation of a potential platform of a cardiac-gated system for treatment of acute and chronic low blood flow states, and diseases requiring augmentation of CSF substance clearance or delivery.
Fresiello, Libera; Gu, Y John; Ferrari, Gianfranco; Di Molfetta, Arianna; Rakhorst, Gerhard
2011-05-01
The pulsatile catheter pump (PUCA pump) is a left ventricular assist device that provides additional flow to the left ventricle. It is usually run in order to ensure a counterpulsation effect, as in the case of the intra-aortic balloon pump (IABP). Because of this similarity, a comparison between the PUCA pump and the IABP was conducted from both the hemodynamic and energetic points of view. Numerical models of the two devices were created and connected to the CARDIOSIM cardiovascular simulator. The PUCA and IABP models were then verified using in vivo experimental data and literature data, respectively. Numerical experiments were conducted for different values of left ventricular end systolic elastance (Els) and systemic arterial compliance (Csa). The energetic comparison was conducted taking into account the diastolic pressure time index and the endocardial viability ratio. Hemodynamic results expressed as cardiac output (CO) and mean coronary blood flow (CBF) show that both the IABP and the PUCA pump efficacy decrease with higher values of Els and Csa. The IABP especially shows higher sensitivity to these parameters, to the extent that in some cases CO actually drops and CBF does not increase. On the other hand, for lower values of Csa, IABP performance improves so much that the PUCA pump flow needs to be increased in order to ensure a hemodynamic effect comparable to that of the IABP. Energetic results show a trend similar to the hemodynamic ones. The study will be continued by investigating other energetic variables and the autonomic response of the cardiovascular system.
Effects of intra-aortic balloon counterpulsation in a model of septic shock.
Solomon, Steven B; Minneci, Peter C; Deans, Katherine J; Feng, Jing; Eichacker, Peter Q; Banks, Steven M; Danner, Robert L; Natanson, Charles; Solomon, Michael A
2009-01-01
Fluid refractory septic shock can develop into a hypodynamic cardiovascular state in both children and adults. Despite management of these patients with empirical inotropic therapy (with or without a vasodilator), mortality remains high. The effect of cardiovascular support using intra-aortic balloon counterpulsation was investigated in a hypodynamic, mechanically ventilated canine sepsis model in which cardiovascular and pulmonary support were titrated based on treatment protocols. Each week, three animals (n = 33, 10-12 kg) were administered intrabronchial Staphylococcus aureus challenge and then randomized to receive intra-aortic balloon counterpulsation for 68 hrs or no intra-aortic balloon counterpulsation (control). Bacterial doses were increased over the study (4-8 x 10(9) cfu/kg) to assess the effects of intra-aortic balloon counterpulsation during sepsis with increasing risk of death. Compared with lower bacterial doses (4-7 x 10(9) colony-forming units/kg), control animals challenged with the highest dose (8 x 10(9) colony-forming units/kg) had a greater risk of death (mortality rate 86% vs. 17%), with worse lung injury ([A - a]O2), and renal dysfunction (creatinine). These sicker animals required higher norepinephrine infusion rates to maintain blood pressure (and higher FIO2) and positive end-expiratory pressure levels to maintain oxygenation (p < or = 0.04 for all). In animals receiving the highest bacterial dose, intra-aortic balloon counterpulsation improved survival time (23.4 +/- 10 hrs longer; p = 0.003) and lowered norepinephrine requirements (0.43 +/- 0.17 microg/kg/min; p = 0.002) and systemic vascular resistance index (1.44 +/- 0.57 dynes/s/cm5/kg; p = 0.0001) compared with controls. Despite these beneficial effects, intra-aortic balloon counterpulsation was associated with an increase in blood urea nitrogen (p = 0.002) and creatinine (p = 0.12). In animals receiving lower doses of bacteria, intra-aortic balloon counterpulsation had no significant effects on survival or renal function. In a canine model of severe septic shock with a low cardiac index, intra-aortic balloon counterpulsation prolongs survival time and lowers vasopressor requirements.
Telemetry Options for LDB Payloads
NASA Technical Reports Server (NTRS)
Stilwell, Bryan D.; Field, Christopher J.
2016-01-01
The Columbia Scientific Balloon Facility provides Telemetry and Command systems necessary for balloon operations and science support. There are various Line-Of-Sight (LOS) and Over-The-Horizon (OTH) systems and interfaces that provide communications to and from a science payload. This presentation will discuss the current data throughput options available and future capabilities that may be incorporated in the LDB Support Instrumentation Package (SIP) such as doubling the TDRSS data rate. We will also explore some new technologies that could potentially expand the data throughput of OTH communications.
Effects of intra-aortic balloon counterpulsation pump on mortality of acute myocardial infarction.
Ye, Liwen; Zheng, Minming; Chen, Qingwei; Li, Guiqion; Deng, Wei; Ke, Dazhi
2014-01-01
Several randomized controlled trials (RCTs) have evaluated the effect of intra-aortic balloon counterpulsation pump(IABP) on the mortality of acute myocardial infarction (AMI). To analyze the relevant RCT data on the effect of IABP on mortality and the occurrence of bleeding in AMI. Published RCTs on the treatment of AMI by IABP were retrieved in searches of Medline, EMBASE, Cochrane and other related databases. The last search was conducted on July 20, 2014. Randomized clinical trials comparing IABP to controls as treatment for AMI. Patients with AMI. The primary endpoint was mortality, and the secondary endpoint was bleeding events. To account for to heterogeneity, a random-effects model was used to analyze the study data. Ten trials with a total population of 973 patients that were included in the analysis showed no significant difference in 2-month mortality between the IABP and the control groups. The 6-month mortality in the IABP group was not significantly lower than in the control group in the four RCTs that enrolled 59 AMI patients with CS. But in the four that enrolled AMI 66 patients without CS, the data showed opposite conclusion. IABP cannot reduce within 2 months and 6-12 months mortality of AMI patients with CS as well as within 2 months mortality of AMI patients without CS, but can reduce 6-12 months mortality of AMI patients without CS. In addition, IABP can increase the risk of bleeding.
Liu, Hongwei; Wu, Xueping; Zhao, Xiaoning; Zhu, Ping
2016-01-01
Objective To examine if mechanical ventilation with positive end-expiratory pressure (PEEP) combined with intra-aortic balloon pump (IABP) provided a better outcome than IABP alone for the treatment of cardiogenic shock after acute myocardial infarction in patients aged > 60 years. Methods This was a retrospective analysis of data from patients in cardiogenic shock, refractory to pharmacological therapy and treated at a geriatric coronary care unit. Results Sixty-two patients were eligible for study inclusion: 33 received IABP alone; 29 received IABP combined with mechanical ventilation. Patients in the IABP + mechanical ventilation group had lower mean arterial blood pressure (BP), systolic BP and partial pressure of oxygen compared with the IABP group, indicating worse cardiac and pulmonary function. In addition, higher rates of pulmonary infection and renal insufficiency were observed in the IABP + mechanical ventilation group than in the IABP group. A statistically significant improvement of left ventricular function before and after treatment was observed in the IABP + mechanical ventilation group, but not in the IABP group. Pulmonary infection and renal insufficiency were risk factors for all-cause in-hospital mortality; successful revascularization was a negative risk factor. There was no between-group difference in survival. Conclusion Mechanical ventilation with an appropriate level of PEEP appears to enhance the beneficial effects of IABP on left ventricular function for patients in cardiogenic shock. PMID:27020597
Determination of balloon gas mass and revised estimates of drag and virtual mass coefficients
NASA Technical Reports Server (NTRS)
Robbins, E.; Martone, M.
1993-01-01
In support of the NASA Balloon Program, small-scale balloons were flown with varying lifting gas and total system mass. Instrument packages were developed to measure and record acceleration and temperature data during these tests. Top fitting and instrument payload accelerations were measured from launch to steady state ascent and through ballast drop transients. The development of the small lightweight self-powered Stowaway Special instrument packages is discussed along with mathematical models developed to determine gas mass, drag and virtual mass coefficients.
Bonios, Michael J; Pierrakos, Charalampos N; Argiriou, Michael; Dalianis, Argirios; Terrovitis, John V; Dolou, Paraskevi; Drakos, Stavros G; Koudoumas, Dimitrios; Charitos, Christos E; Anastasiou-Nana, Maria I
2010-02-04
Studies of the IABP have reported variable effects on coronary blood flow (CBF). The purpose of the present study was to measure the changes in coronary blood flow induced by intra-aortic balloon pump (IABP) counterpulsation in normal and reperfused porcine myocardium. A 30-ml IABP was placed in the descending aorta of 6 open-chest pigs. Each pig underwent occlusion of the mid-left anterior descending (LAD) coronary artery for 1 h, followed by reperfusion for 2 h. The effects of IABP support on systolic aortic pressure (SAP) and aortic end-diastolic pressure were recorded. The mean CBF, distal to the LAD occlusion site was measured at baseline and during reperfusion, with and without IABP counterpulsation. The IABP decreased SAP and aortic end-diastolic pressure in normal and reperfused myocardium, and maintained a peak aortic diastolic augmentation at the level of SAP. In normal myocardium, the IABP decreased mean CBF by 8.4+/-2.2% (p<0.001). At 2, 15, 30, 60, 90 and 120 min of reperfusion, the IABP increased mean CBF by 11.5+/-6.8%, 8.0+/-7.0%, 11.2+/-6.9%, 12.4+/-12.9%, 23.5+/-9.9% and 8.9+/-6.9%, of the corresponding value without the assistance of the IABP (all p<0.05). In the normal heart, IABP counterpulsation decreased CBF, probably because of a decrease in myocardial oxygen demand from a decreased afterload. During reperfusion the IABP increased CBF, suggesting that it might effectively mitigate the no-reflow phenomenon. Copyright 2008 Elsevier Ireland Ltd. All rights reserved.
Flight Qualification of the NASA's Super Pressure Balloon
NASA Astrophysics Data System (ADS)
Cathey, Henry; Said, Magdi; Fairbrother, Debora
Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test flight by successfully demonstrated balloon vehicle performance, obtained a large amount of videos, measured balloon differential pressure, obtained temperature and altitude data, assessed structure strength through pressurization, and demonstrated the balloon vehicles altitude stability. This flight was the first of several to qualify this design for the science community. Results of the most recent flights will be presented. Some of the related material characterization testing which is vital to the balloon design development for the balloon will also be presented. Additionally, this paper will provide a current overview of the development and qualification approach pursued for the NASA’s Super Pressure Balloon. Future plans and goals of future test flights will also be presented. This will include the projected balloon volumes, payload capabilities, test flight locations, and proposed flight schedule.
The 37-day flight of CREAM during the 2009-2010 austral summer
NASA Astrophysics Data System (ADS)
Seo, Eun-Suk
The balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment was launched from McMurdo Station Antarctica on December 1, 2009, an early-launch record for Antarctic Long Duration Balloon (LDB) flights. A cumulative exposure of ˜ 156 days was achieved when this 37-day fifth flight of CREAM was terminated over the Ross Ice Shelf on January 8, 2010. Combining a sampling calorimeter for energy measurement with multiple charge detectors for particle identification, CREAM-V provided a large data sample to measure elemental spectra for 1 ≤ Z ≤ 26 in energies above 1014 eV. This was the first time that CREAM was supported with the standard Support Instrumentation Package (SIP) for LDB payloads. The first four flights were supported by the Command and Data Module (CDM) developed by the NASA Wallops Flight Facility for Ultra Long Duration Balloon (ULDB) flights. The instrument performance, results from the ongoing data analysis, and future plans will be presented.
A New Approach on Sampling Microorganisms from the Lower Stratosphere
NASA Astrophysics Data System (ADS)
Gunawan, B.; Lehnen, J. N.; Prince, J.; Bering, E., III; Rodrigues, D.
2017-12-01
University of Houston's Undergraduate Student Instrumentation Project (USIP) astrobiology group will attempt to provide a cross-sectional analysis of microorganisms in the lower stratosphere by collecting living microbial samples using a sterile and lightweight balloon-borne payload. Refer to poster by Dr. Edgar Bering in session ED032. The purpose of this research is two-fold: first, to design a new system that is capable of greater mass air intake, unlike the previous iterations where heavy and power-intensive pumps are used; and second, to provide proof of concept that live samples are accumulated in the upper atmosphere and are viable for extensive studies and consequent examination for their potential weather-altering characteristics. Multiple balloon deployments will be conducted to increase accuracy and to provide larger set of data. This paper will also discuss visual presentation of the payload along with analyzed information of the captured samples. Design details will be presented to NASA investigators for professional studies
Acoustic Eaton lens array and its fluid application
NASA Astrophysics Data System (ADS)
Kim, Sang-Hoon; Sy, Pham-Van; Das, Mukunda P.
2017-03-01
A principle of an acoustic Eaton lens array and its application as a removable tsunami wall is proposed theoretically. The lenses are made of expandable rubber pillars or balloons and create a stop-band by rotating the incoming tsunami wave and reduce the pressure by canceling each other. The diameter of each lens is larger than the wavelength of the tsunami near the coast, that is, order of a kilometer. The impedance matching on the border of the lenses results in a little reflection. Before a tsunami, the balloons are buried underground in shallow water near the coast in folded or rounded form. Upon sounding of the tsunami alarm, water and air are pumped into the pillars, which expand and erect the wall above the sea level within a few hours. After the tsunami, the water and air are released from the pillars, which are then buried underground for reuse. Electricity is used to power the entire process. A numerical simulation with a linear tsunami model was carried out.
Balloon borne in-situ detection of OH in the stratosphere from 37 to 23 km
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stimpfle, R.M.; Lapson, L.B., Wennberg, P.O.; Anderson, J.G.
1989-12-01
The OH number density in the stratosphere has been measured over the altitude interval of 37 to 23 km at midday via balloon-borne gondola launched from Palestine, Texas on July 6, 1988. OH radicals are detected with a laser induced fluorescence instrument employing a 17 kHz repetition rate copper vapor laser pumped dye laser optically coupled to an enclosed flow, in-situ sampling chamber. OH abundances ranged from 88 {plus minus} 31 pptv (1.1 {plus minus} 0.4 {times} 10{sup 7} molec cm{sup {minus}3}) in the 36 to 35 km interval to 0.9 {plus minus} 0.8 pptv (8.7 {plus minus} 7.7 {times}10{supmore » 5} molec cm{sup {minus}3}) in the 24 to 23 km interval. The stated uncertainty ({plus minus} 1{sigma}) includes that from both measurement precision and accuracy. Simultaneous detection of ozone and water vapor densities was carried out with separate on-board instruments.« less
Improved confinement in highly powered high performance scenarios on DIII-D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrie, Thomas W.; Osborne, Thomas; Fenstermacher, Max E.
DIII-D has recently demonstrated improved energy confinement by injecting neutral deuterium gas into high performance near-double null divertor (DND) plasmas during high power operation. Representative parameters for these plasmas are: q 95 = 6, P IN up to 15 MW, H 98 = 1.4–1.8, and β N = 2.5–4.0. The ion B xmore » $$\\triangledown$$B direction is away from the primary X-point. While plasma conditions at lower to moderate power input (e.g., 11 MW) are shown to be favorable to successful puff-and-pump radiating divertor applications, particularly when using argon seeds, plasma behavior at higher powers (e.g., ≥14 MW) may make successful puff-and-pump operation more problematic. In contrast to lower powered high performance plasmas, both $$\\tau$$ E and β N in the high power cases (≥14 MW) increased and ELM frequency decreased, as density was raised by deuterium gas injection. Improved performance in the higher power plasmas was tied to higher pedestal pressure, which according to peeling-ballooning mode stability analysis using the ELITE code could increase with density along the kink/peeling stability threshold, while the pedestal pressure gradient in the lower power discharges were limited by the ballooning threshold. This resulted in improved fueling efficiency and ≈10% higher $$\\tau$$ E and β N than is normally observed in comparable high performance plasmas on DIII-D. Applying the puff-and-pump radiating divertor approach at moderate versus high power input is shown to result in a much different evolution in core and pedestal plasma behavior. In conclusion, we find that injecting deuterium gas into these highly powered DND plasmas may open up a new avenue for achieving elevated plasma performance, including better fueling, but the resulting higher density may also complicate application of a radiating divertor approach to heat flux reduction in present-day tokamaks, if scenarios involving second-harmonic electron cyclotron heating are used.« less
Improved confinement in highly powered high performance scenarios on DIII-D
Petrie, Thomas W.; Osborne, Thomas; Fenstermacher, Max E.; ...
2017-06-09
DIII-D has recently demonstrated improved energy confinement by injecting neutral deuterium gas into high performance near-double null divertor (DND) plasmas during high power operation. Representative parameters for these plasmas are: q 95 = 6, P IN up to 15 MW, H 98 = 1.4–1.8, and β N = 2.5–4.0. The ion B xmore » $$\\triangledown$$B direction is away from the primary X-point. While plasma conditions at lower to moderate power input (e.g., 11 MW) are shown to be favorable to successful puff-and-pump radiating divertor applications, particularly when using argon seeds, plasma behavior at higher powers (e.g., ≥14 MW) may make successful puff-and-pump operation more problematic. In contrast to lower powered high performance plasmas, both $$\\tau$$ E and β N in the high power cases (≥14 MW) increased and ELM frequency decreased, as density was raised by deuterium gas injection. Improved performance in the higher power plasmas was tied to higher pedestal pressure, which according to peeling-ballooning mode stability analysis using the ELITE code could increase with density along the kink/peeling stability threshold, while the pedestal pressure gradient in the lower power discharges were limited by the ballooning threshold. This resulted in improved fueling efficiency and ≈10% higher $$\\tau$$ E and β N than is normally observed in comparable high performance plasmas on DIII-D. Applying the puff-and-pump radiating divertor approach at moderate versus high power input is shown to result in a much different evolution in core and pedestal plasma behavior. In conclusion, we find that injecting deuterium gas into these highly powered DND plasmas may open up a new avenue for achieving elevated plasma performance, including better fueling, but the resulting higher density may also complicate application of a radiating divertor approach to heat flux reduction in present-day tokamaks, if scenarios involving second-harmonic electron cyclotron heating are used.« less
The financial impact of flipping the coin.
Gonzalez, Katherine W; Reddy, Shiva R; Mundakkal, Angela A; St Peter, Shawn D
2017-01-01
Esophageal foreign body retrieval is typically performed by rigid or flexible esophagoscopy. Despite evidence supporting the efficacy and safety of balloon extraction, it is rarely performed. We sought to establish the financial benefits of this minimally invasive approach. A retrospective review of 241 children with esophageal coins between 2011 and 2013 was performed. Coins were removed via endoscopy or fluoroscopic-guided balloon retrieval. Timing, symptoms, facility cost, and patient charges were compared. Two hundred patients had attempted balloon retrieval with 80% success. Forty-one patients went directly for operative removal. Patients with respiratory difficulty (p=0.05), wheezing (p<0.01), or fever (p=0.03) were more often taken directly for endoscopic retrieval. The median cost and charges for attempted balloon extraction were $484 and $1647. The median cost and charges for primary endoscopy were $1834 and $6746. The median total cost and charges of attempted balloon extraction including ED, OR, transport, admission, and balloon retrieval were $1231 and $3539 versus $3615 and $12,204 in the primary endoscopy group (p<0.001, p<0.001). Seventeen percent of patients who underwent attempted balloon retrieval were admitted prior to removal compared to 76% who underwent primary endoscopy (p<0.001). Fluoroscopic guided balloon extraction of esophageal coins is a financially prudent choice which shortens hospital stay. III. Retrospective treatment and economic study. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Silbert, Mendel N.
1967-01-01
The purpose of this paper is to present results of a system analysis and operational evaluation of a captive airfoil balloon system. The system was used operationally in support of an Aeropalynologic Survey Project at NASA Wallops Island, Virginia, during the summer of 1966.
75 FR 12976 - Amendment of Restricted Area R-2204 High and R-2204 Low; Oliktok Point, AK
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-18
... Oliktok, AK, is required for current moored balloon and future climate-related aviation activities. DATES... in support of the proposed rule stressing the importance of continued climate studies at Oliktok... regions to climate change. In 2004, the need to operate an unlighted moored balloon in clouds resulted in...
NASA Technical Reports Server (NTRS)
Randhawa, J.
1978-01-01
The chemiluminescent ozonesonde to be flown with the STRATCOM balloon flight consisted of two main parts: (1) A constant-volume sampling pump made from TEFLON was used for the intake of the air sample. Sample was drawn at a rate of 200 millimeters per minute. (2) Ozone was detected by the chemiluminescent process (Rhodamine - B). Ozone molecules in the air sample flowed over the detector and the photons produced by the destruction of ozone molecules on the chemiluminescent material were monitored by the photomultiplier tube, the output signal from which was transmitted to the ground receiver.
NASA Technical Reports Server (NTRS)
Crannell, C. J.; Starr, R.; Stottlemyre, A. R.; Trombka, J. I.
1984-01-01
The design, development, and balloon-flight verification of a payload for observations of gamma-ray emission from solar flares are reported. The payload incorporates a high-purity germanium semiconductor detector, standard NIM and CAMAC electronics modules, a thermally stabilized pressure housing, and regulated battery power supplies. The flight system is supported on the ground with interactive data-handling equipment comprised of similar electronics hardware. The modularity and flexibility of the payload, together with the resolution and stability obtained throughout a 30-hour flight, make it readily adaptable for high-sensitivity, long-duration balloon fight applications.
Guidelines and Suggestions for Balloon Gondola Design
NASA Technical Reports Server (NTRS)
Franco, Hugo
2017-01-01
This paper discusses the current gondola design requirements for the Columbia Scientific Balloon Facility (CSBF). The CSBF is responsible for launching and supporting balloon borne scientific instruments and has some current updated guidelines that will be discussed in this presentation. As the sophistication of Payload systems have increased in size and complexity new guidelines have been implemented in order to make these instruments stay within the acceptable launch risks. Additionally, there is a requirement to submit a proper stress analysis report that states the flight design requirements have been met. Suggestions are discussed in this presentation that establish the proper guidelines to submit these.
NASA Scientific Balloon Team Hopes to Break Flight Duration Record with New Zealand Launch
2017-12-08
After years of tests and development, NASA’s Balloon Program team is on the cusp of expanding the envelope in high-altitude, heavy-lift ballooning with its super pressure balloon (SPB) technology. NASA’s scientific balloon experts are in Wanaka, New Zealand, prepping for the fourth flight of an 18.8 million-cubic-foot (532,000 cubic-meter) balloon, with the ambitious goal of achieving an ultra-long-duration flight of up to 100 days at mid-latitudes. Launch of the pumpkin-shaped, football stadium-size balloon is scheduled for sometime after April 1, 2016, from Wanaka Airport, pending final checkouts and flight readiness of the balloon and supporting systems. Once launched, the SPB, which is made from 22-acres of polyethylene film – similar to a sandwich bag, but stronger and more durable – will ascend to a nearly constant float altitude of 110,000 feet (33.5 km). The balloon will travel eastward carrying a 2,260-pound (1,025 kg) payload consisting of tracking, communications and scientific instruments. NASA expects the SPB to circumnavigate the globe once every one to three weeks, depending on wind speeds in the stratosphere. Read more: go.nasa.gov/1p56xKR NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Understanding the C-pulse device and its potential to treat heart failure.
Sales, Virna L; McCarthy, Patrick M
2010-03-01
The Sunshine Heart C-Pulse (C-Pulse; Sunshine Heart Inc., Tustin, CA) device is an extra-aortic implantable counterpulsation pump designed as a non-blood contacting ambulatory heart assist device, which may provide relief from symptoms for class II-III congestive heart failure patients. It has a comparable hemodynamic augmentation to intra-aortic balloon counterpulsation devices. The C-Pulse cuff is implanted through a median sternotomy, secured around the ascending aorta, and pneumatically driven by an external system controller. Pre-clinical studies in the acute pig model, and initial temporary clinical studies in patients undergoing off-pump coronary bypass surgery have shown substantial increase in diastolic perfusion of the coronary vessels, which translated to a favorable improvement in ventricular function. A U.S. prospective multi-center trial to evaluate the safety and efficacy of the C-Pulse in class III patients with moderate heart failure is now in progress.
Lin, Yuan-xiang; Lin, Kun; Kang, De-zhi; Liu, Xin-xiu; Wang, Xing-fu; Zheng, Shu-fa; Yu, Liang-hong; Lin, Zhang-ya
2015-05-01
Dysmorphic neurons and balloon cells constitute the neuropathological hallmarks of type II focal cortical dysplasias (FCDs) with refractory epilepsy. The genesis of these cells may be critical to the histological findings in type II FCD. Recent work has shown enhanced activation of the mTOR cascade in both balloon cells and dysmorphic neurons, suggesting a common pathogenesis for these two neuropathological hallmarks. A direct comparative analysis of balloon cells and dysmorphic neurons might identify a molecular link between balloon cells and dysmorphic neurons. Here, we addressed whether PDK1-AKT-mTOR activation differentiates balloon cells from dysmorphic neurons. We used immunohistochemistry with antibodies against phosphorylated (p)-PDK1 (Ser241), p-AKT (Thr308), p-AKT (Ser473), p-mTOR (Ser2448), p-P70S6K (Thr229), and p-p70S6 kinase (Thr389) in balloon cells compared with dysmorphic neurons. Strong or moderate staining for components of the PDK1-AKT-mTOR signaling pathway was observed in both balloon cells and dysmorphic neurons. However, only a few pyramidal neurons displayed weak staining in control group (perilesional neocortex and histologically normal neocortex). Additionally, p-PDK1 (Ser241) and p-AKT (Thr308) staining in balloon cells were stronger than in dysmorphic neurons, whereas p-P70S6K (Thr229) and p-p70S6 kinase (Thr389) staining in balloon cells was weaker than in dysmorphic neurons. In balloon cells, p-AKT (Ser473) and p-mTOR (Ser2448) staining was comparable with the staining in dysmorphic neurons. Our data support the previously suggested pathogenic relationship between balloon cells and dysmorphic neurons concerning activation of the PDK1-AKT-mTOR, which may play important roles in the pathogenesis of type II FCD. Differential expression of some components of the PDK1-AKT-mTOR pathway between balloon cells and dysmorphic neurons may result from cell-specific gene expression. Copyright © 2015 Elsevier B.V. All rights reserved.
Inquiry-Based Early Undergraduate Research Using High-Altitude Ballooning
NASA Astrophysics Data System (ADS)
Sibbernsen, K.; Sibbernsen, M.
2012-12-01
One common objective for undergraduate science classes is to have students learn how to do scientific inquiry. However, often in science laboratory classes, students learn to take data, analyze the data, and come to conclusions, but they are told what to study and do not have the opportunity to ask their own research questions, a crucial part of scientific inquiry. A special topics class in high-altitude ballooning (HAB) was offered at Metropolitan Community College, a large metropolitan two-year college in Omaha, Nebraska to focus on scientific inquiry for the participants through support of NASA Nebraska Space Grant. A weather balloon with payloads attached (balloonSAT) was launched to near space where the balloon burst and fell back to the ground with a parachute. Students worked in small groups to ask their research questions, they designed their payloads, participated in the launch and retrieval of equipment, analyzed data, and presented the results of their research. This type of experience has potential uses in physics, physical science, engineering, electronics, computer programming, meteorology, astronomy, and chemistry classes. The balloonSAT experience can act as a stepping-stone to designing sounding rocket payloads and it can allow students the opportunity to participate in regional competitions and present at HAB conferences. Results from the workshop are shared, as well as student responses to the experience and suggestions for administering a high-altitude ballooning program for undergraduates or extending inquiry-based ballooning experiences into high-school or middle-school.
Gon, Shigeyoshi; Suematsu, Yoshihito; Morizumi, Sei; Shimizu, Tsuyoshi
2011-09-01
A 19-year-old woman suffered fulminant myocarditis owing to a mycoplasma infection and was inserted with an intra-aortic balloon pump and a percutaneous cardiopulmonary support. Antibiotics and gamma globulin were administered, however, the patient's cardiac function did not recover, and the TOYOBO ventricular assist device (VAD) was implanted. She had rehabilitation training such as maintaining a standing position at the bedside and walking in the hospital, and a hospital outing program to a family restaurant was conducted two times with the VAD. The patient wished to attend the coming-of-age ceremony in Tachikawa city, which is 3 h away from our hospital by car. Therefore, we planned the program including a night stay at her home. The patient and her family fully understood the risks and wished to participate in the sleepover program. In preparing for the sleepover, the patient and her family learned to operate the VAD, and she was able to move to the lavatory and through the house with the help of only her family. A physician and a clinical engineer stayed at her house for infusion of antibiotics and management of sudden changes. There was no adverse event. In Japan, the community support of patients with VAD is not yet established, and we hope that our experience becomes a help to support return to society for patients with VAD.
Meteorological Support in Scientific Ballooning
NASA Technical Reports Server (NTRS)
Schwantes, Chris; Mullenax, Robert
2016-01-01
The weather affects every portion of a scientific balloon mission, from payload integration to launch, float, and impact and recovery. Forecasting for these missions is very specialized and unique in many aspects. CSBF Meteorology incorporates data from NWSNCEP, as well as several international meteorological organizations, and NCAR. This presentation will detail the tools used and specifics on how CSBF Meteorology produces its forecasts.
Meteorological Support in Scientific Ballooning
NASA Technical Reports Server (NTRS)
Schwantes, Chris; Mullenax, Robert
2017-01-01
The weather affects every portion of a scientific balloon mission, from payload integration to launch, float, and impact and recovery. Forecasting for these missions is very specialized and unique in many aspects. CSBF Meteorology incorporates data from NWSNCEP, as well as several international meteorological organizations, and NCAR. This presentation will detail the tools used and specifics on how CSBF Meteorology produces its forecasts.
Australasian trends in intra-aortic balloon counterpulsation weaning: results of a postal survey.
Lewis, Peter A; Mullany, Daniel V; Courtney, Mary; Coyer, Fiona
2006-12-01
To generate baseline data describing Australasian intra-aortic balloon counterpulsation (IABP) weaning practice. A five-part questionnaire was mailed in April 2005 to all 192 intensive care units in Australia and New Zealand. 116 ICUs responded (response rate, 60%), and 54 reported using IABP. Most of the 54 were in hospitals which were public government-funded (65%), had between 100 and 500 beds (69%), and treated a minimum of 11 patients annually with IABP (60%). The most common method of withdrawing IABP support was ratio reduction alone (61%). ICUs most likely to undertake ratio weaning were higherend users of IABP (> 20 cases per annum) (P = 0.04). Other weaning practices involved a combination of ratio followed by volume reduction (17%), volume then ratio (11%), and volume only (4%). Approaching statistical significance, ratio reduction weaning less frequently required IABP reinsertion or inotropic increase after balloon removal (P = 0.07). ICUs with documented weaning policies were less likely to require IABP reinsertion or inotropic increase after balloon removal (P = 0.06). Criteria considered important before IABP weaning or removal were: blood pressure (92%); heart rate (76%); pulmonary artery wedge pressure (59%); noradrenaline dose (78%); adrenaline dose (57%); and dobutamine dose (57%). Ninety per cent of ICUs reported increasing inotropes after balloon removal only rarely (1:50 patients) or occasionally (1:10 patients), while 87% of ICUs reported never needing to reinsert the balloon or only rarely. The Australasian approach to IABP weaning is eclectic. While ratio reduction weaning appears the most successful manner of support withdrawal, it may be a consequence of a volume-outcome relationship, with high- end users achieving better results through IABP familiarity.
Schiariti, Michele; Saladini, Patrizia; Cuturello, Domenico; Iannetta, Loredana; Torromeo, Concetta; Puddu, Paolo Emilio
2014-04-01
Thrombocytopenia (TC) following a percutaneous coronary intervention (PCI) has been associated not only with hemorrhagic, but also with ischemic outcomes. The purpose of this study was to re-examine the relationship of TC with ischemic events at a 1-year follow-up, and investigate the possible associations. We studied a real-world, unselected population of ischemic patients undergoing PCI, totaling 861 patients-year, and divided into two groups: with TC (delta platelet count ≥25% from baseline to post-PCI during the hospital admission) and without TC. Compared with patients without TC, patients with TC had a higher and earlier incidence of both hemorrhagic and ischemic events. In them, the use of intra-aortic balloon pump (IABP) was ten-fold higher. In Kaplan-Meier curves assessing the contribution of both TC and IABP to outcome, IABP was a univariate detrimental factor additive to the role of TC. In a forced Cox model, the relative decline (delta) in platelet count (p=0.05) and the use of IABP (p=0.0001) were both associated with ischemic outcomes. After excluding all patients with IABP, the delta platelet count was no longer significantly associated with ischemic outcomes (p=0.66). After excluding all patients with shock and all those who undergone thrombolysis, there was still a relationship (p=0.0042) between the delta platelet count and ischemic events. In this patient population the use of IABP, but not thrombocytopenia per se, is a possible primary cause of worse ischemic outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.
Schiariti, Michele; Saladini, Patrizia; Cuturello, Domenico; Iannetta, Loredana; Torromeo, Concetta; Puddu, Paolo Emilio
2014-01-01
Thrombocytopenia (TC) following a percutaneous coronary intervention (PCI) has been associated not only with hemorrhagic, but also with ischemic outcomes. The purpose of this study was to re-examine the relationship of TC with ischemic events at a 1-year follow-up, and investigate the possible associations. We studied a real-world, unselected population of ischemic patients undergoing PCI, totaling 861 patients-year, and divided into two groups: with TC (delta platelet count ≥25% from baseline to post-PCI during the hospital admission) and without TC. Compared with patients without TC, patients with TC had a higher and earlier incidence of both hemorrhagic and ischemic events. In them, the use of intra-aortic balloon pump (IABP) was ten-fold higher. In Kaplan-Meier curves assessing the contribution of both TC and IABP to outcome, IABP was a univariate detrimental factor additive to the role of TC. In a forced Cox model, the relative decline (delta) in platelet count (p=0.05) and the use of IABP (p=0.0001) were both associated with ischemic outcomes. After excluding all patients with IABP, the delta platelet count was no longer significantly associated with ischemic outcomes (p=0.66). After excluding all patients with shock and all those who undergone thrombolysis, there was still a relationship (p=0.0042) between the delta platelet count and ischemic events. In this patient population the use of IABP, but not thrombocytopenia per se, is a possible primary cause of worse ischemic outcomes. Copyright © 2013 Elsevier Inc. All rights reserved.
Effects of Intra-Aortic Balloon Counterpulsation Pump on Mortality of Acute Myocardial Infarction
Ye, Liwen; Zheng, Minming; Chen, Qingwei; Li, Guiqion; Deng, Wei; Ke, Dazhi
2014-01-01
Background Several randomized controlled trials (RCTs) have evaluated the effect of intra-aortic balloon counterpulsation pump(IABP) on the mortality of acute myocardial infarction (AMI). Objectives To analyze the relevant RCT data on the effect of IABP on mortality and the occurrence of bleeding in AMI. Data Sources Published RCTs on the treatment of AMI by IABP were retrieved in searches of Medline, EMBASE, Cochrane and other related databases. The last search was conducted on July 20, 2014. Study Eligibility Criteria Randomized clinical trials comparing IABP to controls as treatment for AMI. Participants Patients with AMI. Synthesis Methods The primary endpoint was mortality, and the secondary endpoint was bleeding events. To account for to heterogeneity, a random-effects model was used to analyze the study data. Results Ten trials with a total population of 973 patients that were included in the analysis showed no significant difference in 2-month mortality between the IABP and the control groups. The 6-month mortality in the IABP group was not significantly lower than in the control group in the four RCTs that enrolled 59 AMI patients with CS. But in the four that enrolled AMI 66 patients without CS, the data showed opposite conclusion. Conclusions IABP cannot reduce within 2 months and 6–12 months mortality of AMI patients with CS as well as within 2 months mortality of AMI patients without CS, but can reduce 6–12 months mortality of AMI patients without CS. In addition, IABP can increase the risk of bleeding. PMID:25268800
[Analysis of vascular complications of IABP therapy in open-heart surgery patients 1999-2004].
Kovács, Endre; Becker, Dávid; Daróczi, László; Gálfy, Ildikó; Hüttl, Tivadar; Laczkó, Agnes; Paukovits, Tamas; Vargha, Péter; Szabolcs, Zoltán
2006-04-01
Intraaortic balloon pump (IABP) is being used in cardiac surgery in an increased ratio. IABP therapy involves considerable risk, mainly vascular complications, postoperative bleeding and infection can represent danger. Between 1999 and 2004 out of 4443 open heart surgery operations we have performed intraaortic balloon pump treatment in case of 75 patients. The mean age was 64 years, 23 patients had diabetes mellitus, 47 patients had hypertension, 20 patients had peripheral vascular disease as well. We performed IABP therapy most frequently during isolated coronary bypass operations (42 cases), but also combined operations (implantation of valve prosthesis + coronary bypass) represent a significant part (implantation of aortic valve prosthesis + CABG: 5 cases, implantation of mitral valve prosthesis + CABG: 8 cases). Vascular complications occurred in 10 cases--13.3%--out of 75 patients, including 7 fatal ones. Three cases are due to the IABP treatment itself: Crush syndrome was developed leading to the loss of the patient. Applying the multiple logistic regression model we have examined the effect of the following factors on the occurrence of vascular complications: gender, age, body surface, accompanying diseases (hypertension, diabetes, peripheral vascular disease), the method and timing of insertion. Peripheral vascular disease (p < 0.005) and hypertension (p = 0.01) represent independent risk factors regarding the occurrence of complications. Having performed chi-square test we have not identified significant correlations between mortality and vascular complications. In case of prevailing peripheral vascular disease, the application of alternative insertion techniques--via the ascending aorta, the axillary artery--are recommended.
Bakker, E W M; Visser, K; van der Wal, A; Kuiper, M A; Koopmans, M; Breedveld, R
2012-09-01
The primary goal of this observational clinical study was to register the occurrence of incorrect inflation and deflation timing of an intra-aortic balloon pump in autoPilot mode. The secondary goal was to identify possible causes of incorrect timing. During IABP assistance of 60 patients, every four hours a strip was printed with the IABP frequency set to 1:2. Strips were examined for timing discrepancies beyond 40 ms from the dicrotic notch (inflation) and the end of the diastolic phase (deflation). In this way, 320 printed strips were examined. A total of 52 strips (16%) showed incorrect timing. On 24 of these strips, the incorrect timing was called incidental, as it showed on only one or a few beats. The other 28 cases of erroneous timing were called consistent, as more than 50% of the beats on the strip showed incorrect timing. We observed arrhythmia in 69% of all cases of incorrect timing. When timing was correct, arrhythmia was found on 13 (5%) of 268 strips. A poor quality electrocardiograph (ECG) signal showed on 37% of all strips with incorrect timing and 11% of all strips with proper timing. We conclude that inflation and deflation timing of the IABP is not always correct when using the autoPilot mode. The quality of the ECG input signal and the occurrence of arrhythmia appear to be related to erroneous timing. Switching from autoPilot mode to operator mode may not always prevent incorrect timing.
Zhang, Qun; Lin, Shi-Rong; He, Fang; Kang, De-Hua; Chen, Guo-Zhang; Luo, Wei
2011-11-01
Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volumes and normal tissues in postoperative intensity-modulated radiotherapy (IMRT) after placing a water-filled balloon into the resection cavity. Three postoperative patients with advanced maxillary sinus carcinoma were selected in this trial. Water-filled balloons and supporting dental stents were fabricated according to the size of the maxillary resection cavity. Simulation CT scans were performed with or without water-filled balloons, IMRT treatment plans were established, and dose distribution to target volumes and organs at risk were evaluated. Compared to those in the treatment plan without balloons, the dose (D98) delivered to 98% of the gross tumor volume (GTV) increased by 2.1 Gy (P = 0.009), homogeneity index (HI) improved by 2.3% (P = 0.001), and target volume conformity index (TCI) of 68 Gy increased by 18.5% (P = 0.011) in the plan with balloons. Dosimetry endpoints of normal tissues around target regions in both plans were not significantly different (P > 0.05) except for the optic chiasm. In the plan without balloons, 68 Gy high-dose regions did not entirely cover target volumes in the ethmoid sinus, posteromedial wall of the maxillary sinus, or surgical margin of the hard palate. In contrast, 68 Gy high-dose regions entirely covered the GTV in the plan with balloons. These results suggest that placing a water-filled balloon in the resection cavity for postoperative IMRT of maxillary sinus carcinoma can reduce low-dose regions and markedly and simultaneously increase dose homogeneity and conformity of target volumes.
Ballooning in the constant sun of the South Pole summer
2017-12-08
BARREL researchers get ready to release the top part of the balloon, called the bubble, as it fills with enough helium to support itself. Only the top part of the balloon is inflated before launch since the helium expands as the balloon ascends. Credit: NASA/Goddard/BARREL/Nicky Knox Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
NASA Technical Reports Server (NTRS)
Jacobson, M. R.; Harwit, M.; Frederick, C.; Ward, D. B.; Melnick, G.; Stasavage, G.
1978-01-01
Nine additional radiation sources, above a 3-sigma confidence level of 1300 Jy, were identified at 100 microns by far infrared photometry of the galactic plane using a 0.4 meter aperture, liquid helium cooled, multichannel far infrared balloon-borne telescope. The instrument is described, including its electronics, pointing and suspension systems, and ground support equipment. Testing procedures and flight staging are discussed along with the reduction and analysis of the data acquired. The history of infrared astronomy is reviewed. General infrared techniques and the concerns of balloon astronomers are explored.
Pressman, Andrew; Sawyer, Kelly N; Devlin, William; Swor, Robert
2018-05-01
The role of circulatory support in the post-cardiac arrest period remains controversial. Our objective was to investigate the association between treatment with a percutaneous hemodynamic support device and outcome after admission for cardiac arrest. We performed a retrospective study of adult patients with admission diagnosis of cardiac arrest or ventricular fibrillation (VF) from the Michigan Inpatient Database, treated between July 1, 2010, and June 30, 2013. Patient demographics, clinical characteristics, treatments, and disposition were electronically abstracted based on ICD-9 codes at the hospital level. Mixed-effects logistic regression models were fit to test the effect of percutaneous hemodynamic support device defined as either percutaneous left ventricular assist device (pLVAD) or intra-aortic balloon pump (IABP) on survival. These models controlled for age, sex, VF, myocardial infarction (MI), and cardiogenic shock with hospital modeled as a random effect. A total of 103 hospitals contributed 4393 patients for analysis, predominately male (58.8%) with a mean age of 64.1years (SD 15.5). On univariate analysis, younger age, male sex, VF as the initial rhythm, acute MI, percutaneous coronary intervention, percutaneous hemodynamic support device, and absence of cardiogenic shock were associated with survival to discharge (each p<0.001). Mixed-effects logistic regressions revealed use of percutaneous hemodynamic support device was significantly associated with survival among all patients (OR 1.8 (1.28-2.54)), and especially in those with acute MI (OR 1.95 (1.31-2.93)) or cardiogenic shock (OR 1.96 (1.29-2.98)). Treatment with percutaneous hemodynamic support device in the post-arrest period may provide left ventricular support and improve outcome. Copyright © 2017 Elsevier Inc. All rights reserved.
Dickinson, Robert J.; Wasko, John; Pennell, William E.
1984-01-01
A liquid metal pump bearing support comprises a series of tangentially oriented spokes that connect the bearing cylinder to the pump internals structure. The spokes may be arranged in a plurality of planes extending from the bearing cylinder to the pump internals with the spokes in one plane being arranged alternately with those in the next plane. The bearing support structure provides the pump with sufficient lateral support for the bearing structure together with the capability of accommodating differential thermal expansion without adversely affecting pump performance.
Artificial Organs 2016: A Year in Review.
Hadsell, Angela T; Malchesky, Paul S
2017-03-01
In this Editor's Review, articles published in 2016 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, the International Society for Mechanical Circulatory Support, the International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We were pleased to publish our second Virtual Issue in April 2016 on "Tissue Engineering in Bone" by Professor Tsuyoshi Takato. Our first was published in 2011 titled "Intra-Aortic Balloon Pumping" by Dr. Ashraf Khir. Other peer-reviewed Special Issues this year included contributions from the 11th International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion edited by Dr. Akif Ündar and selections from the 23rd Congress of the International Society for Rotary Blood Pumps edited by Dr. Bojan Biocina. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, John Wiley & Sons for their expert attention and support in the production and marketing of Artificial Organs. We look forward to reporting further advances in the coming years. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Chen, Dong-Yi; Tsai, Ming-Lung; Lin, Yu-Sheng; Cherng, Wen-Jin; Wang, Chao-Hung; Wen, Ming-Shien; Hsieh, I-Chang; Hung, Ming-Jui; Chen, Chun-Chi; Chen, Tien-Hsing
2016-01-01
Background Prior studies have suggested intraaortic balloon pump (IABP) have a neutral effect on acute myocardial infarction (AMI) patients with cardiogenic shock (CS). However, the effects of IABP on patients with severe CS remain unclear. We therefore investigated the benefits of IABP in AMI patients with severe CS undergoing coronary revascularization. Methods and Results This study identified 14,088 adult patients with AMI and severe CS undergoing coronary revascularization from Taiwan’s National Health Insurance Research Database between January 1, 1997 and December 31, 2011, dividing them into the IABP group (n = 7044) and the Nonusers group (n = 7044) after propensity score matching to equalize confounding variables. The primary outcomes included myocardial infarction(MI), cerebrovascular accidents or cardiovascular death. In-hospital events including dialysis, stroke, pneumonia and sepsis were secondary outcomes. Primary outcomes were worse in the IABP group than in the Nonusers group in 1 month (Hazard ratio (HR) = 1.97, 95% confidence interval (CI) = 1.84–2.12). The MI rate was higher in the IABP group (HR = 1.44, 95% CI = 1.16–1.79), and the cardiovascular death was much higher in the IABP group (HR = 2.07, 95% CI = 1.92–2.23). The IABP users had lower incidence of dialysis (8.5% and 9.5%, P = 0.04), stroke (2.6% and 3.8%, P<0.001), pneumonia (13.9% and 16.5%, P<0.001) and sepsis (13.2% and 16%, P<0.001) during hospitalization than Nonusers. Conclusion The use of IABP in patients with myocardial infarction and severe cardiogenic shock undergoing coronary revascularization did not improve the outcomes of recurrent myocardial infarction and cardiovascular death. However, it did reduce the incidence of dialysis, stroke, pneumonia and sepsis during hospitalization. PMID:27483439
The French Balloon Program 2013 - 2017
NASA Astrophysics Data System (ADS)
Dubourg, Vincent; Vargas, André; Raizonville, Philippe
2016-07-01
With over 50 years' experience in the field, the French Centre National d'Etudes Spatiales (CNES) goes on supporting - as designer and operator - a significant scientific ballooning program. In particular so because balloons still give a unique and valuable access to near space science. From 2008 to 2013, an important renovation effort was achieved, beginning by Zero Pressure Balloons (ZPB) systems, to comply with more stringent Safety constraints and to the growing reliability and performance requirements from scientific missions. The paper will give an overview of the CNES new capabilities and services for operational balloon activities, and their availability status. The scientific launch campaigns of the past two years will be presented. A focus will be made on the results of the Stratoscience 2015 flight campaign from Timmins, Ontario, using the NOSYCA command and control system for ZPB, qualified in flight in 2013. In particular, the PILOT telescope successfully flew during the 2015 campaign, key figures about the flight and mission will be given. An outlook of the new stratospheric long duration flight systems currently in process of developement at CNES will be given, as well as the presentation of the Stratéole 2 project, dedicated to the survey of the low stratosphere and upper troposphere in equatorial regions, with a fleet of small suprer pressure balloons (SPB). As far as tropospheric balloons are concerned, the Aeroclipper initiative will be presented, aiming at qualifying a quasi-tethered balloon, pushed by the winds close to the sea surface, for the study of cyclones. The scientific launch campaigns and the main payloads in the study for the near future will also be presented.
Richard, Michele; Krol, Emilia; Dietzek, Alan
2016-10-01
To describe the use of orbital technique of atherectomy as an adjunct to successful angioplasty and stent placement of the superior mesenteric artery (SMA). The technique is demonstrated in a 68-year-old man with critical SMA stenosis. The SMA was cannulated with 0.014-in wire, but the lesion was highly stenotic and densely calcified and prevented the passage of even the smallest 1.5-mm balloon. Orbital atherectomy was thus performed with a 1.25-mm CSI crown. Balloon angioplasty was then possible with a 4 mm × 2 cm balloon followed by placement of a 7 mm × 22 mm balloon-mounted stent. The use of atherectomy as an adjunct to angioplasty and stenting in extensive, calcified SMA lesions supports the value of this technique to avoid a much larger and morbid open procedure. Published by Elsevier Inc.
Long-term left ventricular assist device use before transplantation.
Sapirstein, J S; Pae, W E; Aufiero, T X; Boehmer, J P; Pierce, W S
1995-01-01
Between September 1992 and April 1995, 19 patients at the authors' institution received pneumatic, pulsatile left ventricular assist devices (LVADs) for bridging to cardiac transplantation. The mean (+/- SD) age of the patients was 51 +/- 14 years (range, 19-64 years). Nine (47%) patients had end-stage idiopathic cardiomyopathy, five (26%) had ischemic cardiomyopathy, and five (26%) other recipients were in cardiogenic shock caused by acute myocardial infarction (AMI). Fifteen (79%) patients were supported with an intraaortic balloon pump or centrifugal LVAD at the time of LVAD insertion (duration, 5.5 +/- 4.1 days). Aprotinin was given to limit bleeding; heparin, followed by warfarin sodium, was used for anticoagulation. A vigorous exercise and nutrition protocol was followed. Cardiac index averaged 2.94 +/- 0.87 L/min/m2 immediately after the implantation procedure. No patient required placement of a right VAD. Average duration of LVAD support was 45 +/- 39 days (range, 3-153 days). Major complications included bleeding requiring reoperation (three patients); cerebrovascular accident (three patients); and severe dysrhythmias requiring direct current cardioversion (four patients). Fourteen (74%) patients underwent transplantation, with one patient still being mechanically supported. All of the patients receiving transplants were discharged from the hospital. Of the individuals who died while supported with the LVAD, 75% were patients with AMI. Timely application of LVADs as part of the interdisciplinary management of end-stage heart disease has generated excellent results for transplant candidates. Right ventricular dysfunction has not necessitated right VAD placement in the authors' experience. Patients with AMI have a higher risk of death while being supported with the device than do more chronically ill recipients.
Bahekar, Amol; Singh, Mukesh; Singh, Sarabjeet; Bhuriya, Rohit; Ahmad, Khraisat; Khosla, Sandeep; Arora, Rohit
2012-03-01
Intra-aortic balloon pump (IABP) has been widely used ever since it was first developed in 1962 and became part of clinical practice in 1968. It is used to treat patients with complications of acute myocardial infarction (AMI) such as cardiogenic shock, refractory left ventricular failure, and for high-risk patients undergoing angioplasty and coronary artery bypass grafting. However, current literature demonstrates a significant variance in terms of indications for using IABP and its outcomes. The aim of this study is to review the existing literature to analyze whether the use of IABP offers any cardiovascular benefit to the patients with AMI and the complications associated with the use of IABP. Material and A systematic review of literature identified 16 studies. We analyzed the primary endpoint (in-hospital mortality, reinfarction, recurrent ischemia) and secondary endpoint (incidence of moderate and severe bleeding during hospitalization at 7 days). We estimated the proportion of between-study inconsistency (heterogeneity) due to true differences between studies (rather than differences due to random error or chance) using the I2 statistic. Mantel-Haenszel fixed-effect model was used to calculate the combined relative risks (RRs) when studies were homogenous, and the random effect model was used when studies were heterogenic. A 2-sided α error <.05 was considered statistically significant. Meta-analysis revealed that in-hospital mortality of patients with AMI with and without cardiogenic shock did not differ between IABP group as compared to no IABP group (RR: 1.11; confidence interval [CI]: 0.69-1.78; P = .67). However, analysis of patients with AMI with cardiogenic shock showed statistically significant improvement in mortality (RR: 0.72; CI: 0.60-0.86; P < .0004). There was no significant reduction in the rate of reinfarction (RR: 0.81; CI: 0.30-2.17; P = .67) or recurrent ischemia (RR: 0.78; CI: 0.34-1.78; P = .55) using IABP. Intra-aortic balloon pump was found to significantly increase the risk of moderate bleeding (RR: 1.71; CI: 1.03-2.85; P = .04) and major bleeding (RR: 4.01; CI: 2.66-6.06; P < .0001). The present meta-analysis suggests that patients with high-risk AMI without cardiogenic shock do not seem to benefit from the use of IABP as measured by in-hospital mortality, rate of reinfarction, and recurrent angina. However, in patients with AMI with cardiogenic shock (systolic blood pressure [SBP] < 90), there was significant reduction in mortality using IABP. The use of IABP is associated with increase in the rate of both moderate and severe bleeding.
den Uil, Corstiaan A; Akin, Sakir; Jewbali, Lucia S; Dos Reis Miranda, Dinis; Brugts, Jasper J; Constantinescu, Alina A; Kappetein, Arie Pieter; Caliskan, Kadir
2017-07-01
Short-term mechanical circulatory support (MCS) is increasingly used as a bridge to decision in patients with refractory cardiogenic shock. Subsequently, these patients might be bridged to durable MCS either as a bridge to candidacy/transplantation, or as destination therapy. The aim of this study was to review support duration and clinical outcome of short-term MCS in cardiogenic shock, and to analyse application of this technology as a bridge to long-term cardiac support (left ventricular assist device, LVAD) from 2006 till June 2016. Using Cochrane Register of Trials, Embase and Medline, a systematic review was performed on patients with cardiogenic shock from acute myocardial infarction, end-stage cardiomyopathy, or acute myocarditis, receiving short-term MCS. Studies on periprocedural, post-cardiotomy and cardiopulmonary resuscitation support were excluded. Thirty-nine studies, mainly registries of heterogeneous patient populations (n = 4151 patients), were identified. Depending on the device used (intra-aortic balloon pump, TandemHeart, Impella 2.5, Impella 5.0, CentriMag and peripheral veno-arterial extracorporeal membrane oxygenation), mean support duration was (range) 1.6-25 days and the mean proportion of short-term MCS patients discharged was (range) 45-66%. The mean proportion of bridge to durable LVAD was (range) 3-30%. Bridge to durable LVAD was most frequently performed in patients with end-stage cardiomyopathy (22 [12-35]%). We conclude that temporary MCS can be used to bridge patients with cardiogenic shock towards durable LVAD. Clinicians are encouraged to share their results in a large multicentre registry in order to investigate optimal device selection and best duration of support. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Automatic intraaortic balloon pump timing using an intrabeat dicrotic notch prediction algorithm.
Schreuder, Jan J; Castiglioni, Alessandro; Donelli, Andrea; Maisano, Francesco; Jansen, Jos R C; Hanania, Ramzi; Hanlon, Pat; Bovelander, Jan; Alfieri, Ottavio
2005-03-01
The efficacy of intraaortic balloon counterpulsation (IABP) during arrhythmic episodes is questionable. A novel algorithm for intrabeat prediction of the dicrotic notch was used for real time IABP inflation timing control. A windkessel model algorithm was used to calculate real-time aortic flow from aortic pressure. The dicrotic notch was predicted using a percentage of calculated peak flow. Automatic inflation timing was set at intrabeat predicted dicrotic notch and was combined with automatic IAB deflation. Prophylactic IABP was applied in 27 patients with low ejection fraction (< 35%) undergoing cardiac surgery. Analysis of IABP at a 1:4 ratio revealed that IAB inflation occurred at a mean of 0.6 +/- 5 ms from the dicrotic notch. In all patients accurate automatic timing at a 1:1 assist ratio was performed. Seventeen patients had episodes of severe arrhythmia, the novel IABP inflation algorithm accurately assisted 318 of 320 arrhythmic beats at a 1:1 ratio. The novel real-time intrabeat IABP inflation timing algorithm performed accurately in all patients during both regular rhythms and severe arrhythmia, allowing fully automatic intrabeat IABP timing.
Pennell, William E.
1982-01-01
The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair.
Hanna, Elias B; Ababneh, Bashar A; Amin, Amit N
2018-02-01
We describe our experience in transradial recanalization of the superficial femoral artery (SFA), and we provide a stepwise approach accounting for the patient's height and optimizing the yield of currently available devices. Fifteen patients with simple SFA disease, including 4 patients with total SFA occlusions <15 cm, were selected for stand-alone transradial recanalization. A 6F, 125-cm multipurpose guiding catheter was used to cannulate the limb of interest and support device delivery. The procedure was successful in all patients and consisted of balloon angioplasty (using 0.014″, 200-cm shaft monorail balloons) in all patients, and orbital atherectomy in 6 patients. We illustrate the steps and challenges of the transradial approach, namely the limited support in complex disease and the limited reach of current equipment. In patients with simple SFA disease, transradial recanalization appears feasible and safe but currently limited to balloon angioplasty ± orbital atherectomy. Proximal SFA stenting may be feasible in patients <160 cm in height.
Kashiwa, Koichi; Nishimura, Takashi; Saito, Aya; Kubo, Hitoshi; Fukaya, Aoi; Tamai, Hisayoshi; Yambe, Tomoyuki; Kyo, Shunei; Ono, Minoru
2012-06-01
Since left heart bypass or biventricular circulatory assist with an extracorporeal centrifugal pump as a bridge to decision or recovery sometimes requires long-time support, the long-term durability of extracorporeal centrifugal pumps is crucial. The Rotaflow Centrifugal Pump(®) (MAQUET Cardiopulmonary AG, Hirrlingen, Germany) is one of the centrifugal pumps available for long-term use in Japan. However, there have been few reports of left heart bypass or biventricular circulatory support over the mid-term. This is a case report of left heart bypass support with the Rotaflow Centrifugal Pump(®) as a bridge to decision and recovery for an adult patient who could not be weaned from cardiopulmonary bypass and percutaneous cardiopulmonary support after cardiac surgery. We could confirm that the patient's consciousness level was normal; however, the patient could not be weaned from the left heart bypass support lasting 1 month. Therefore, the circulatory assist device was switched to the extracorporeal Nipro ventricular assist device (VAD). This time, left heart bypass support could be maintained for 30 days using a single Rotaflow Centrifugal Pump(®). There were no signs of hemolysis during left heart bypass support. The Rotaflow Centrifugal Pump(®) itself may be used as a device for a bridge to decision or recovery before using a VAD in cardiogenic shock patients.
Kirsch, Matthias; Vermes, Emmanuelle; Damy, Thibaud; Nakashima, Kuniki; Sénéchal, Mélanie; Boval, Bernadette; Drouet, Ludovic; Loisance, Daniel
2009-01-01
Temporary mechanical circulatory support may be indicated in some patients with cardiac failure refractory to conventional therapy, as a bridge to myocardial recovery or transplantation. To evaluate outcomes in cardiogenic shock patients managed by the primary use of a paracorporeal ventricular assist device (p-VAD). We did a retrospective analysis of demographics, clinical characteristics and survival of patients assisted with a Thoratec p-VAD. p-VADs were used in 84 patients with cardiogenic shock secondary to acute myocardial infarction (35%), idiopathic (31%) or ischaemic (12%) cardiomyopathy, myocarditis or other causes (23%). Before implantation, 23% had cardiac arrest, 38% were on a ventilator and 31% were on an intra-aortic balloon pump. Cardiac index was 1.6+/-0.5 L/min/m(2) and total bilirubin levels were 39+/-59 micromol/L. During support, 29 patients (35%) died in the intensive care unit and seven (10%) died after leaving. Forty-seven patients (56%) were weaned or transplanted, with one still under support. Despite significantly more advanced preoperative end-organ dysfunction, survival rates were similar in patients with biventricular devices (74%) and those undergoing isolated left ventricular support (24%) (63% versus 45%, respectively; p=0.2). Actuarial survival estimates after transplantation were 78.7+/-6.3%, 73.4+/-6.9% and 62.6+/-8.3% at 1, 3 and 5 years, respectively. Our experience validates the use of p-VAD as a primary device to support patients with cardiogenic shock. In contrast to short-term devices, p-VADs provide immediate ventricular unloading and pulsatile perfusion in a single procedure. Biventricular support should be used liberally in patients with end-organ dysfunction.
Risk modeling for ventricular assist device support in post-cardiotomy shock.
Alsoufi, Bahaaldin; Rao, Vivek; Tang, Augustine; Maganti, Manjula; Cusimano, Robert
2012-04-01
Post-cardiotomy shock (PCS) has a complex etiology. Although treatment with inotrops and intra-aortic balloon pump (IABP) support improves cardiac performance, end-organ injuries are common and lead to prolonged ICU stay, extended hospitalization and increased mortality. Early consideration of mechanical circulatory support may prevent such complications and improve outcome. Between January 1997 and January 2002, 321 patients required IABP and inotropic support for PCS following coronary artery bypass grafting (CABG) at our institution. Perioperative variables including age, mixed venous saturation (MVO2), inotropic requirements and LV function were analyzed using multivariate statistical methods. All explanatory variables with a univariate p value <0.10 were entered into a stepwise logistic regression model to predict hospital mortality. Odds ratios from significant variables (p < 0.05) in the regression model were used to compose a risk score. Overall hospital mortality was 16%. The independent risk factors for mortality in this population were: MVO2 < 60% (OR = 3.2), milrinone > 0.5 μg/kg/min (OR = 3.2), age > 75 (OR = 2.7), adrenaline > 0.1 μg/kg/min (OR = 1.5). A 15-point risk score was developed based on the regression model. Hospital mortality in patients with a score >6 was 46% (n = 13/28), 3-6 was 31% (n = 9/29) and <3 was 11% (n = 29/264). A significant proportion of patients with PCS continue to face high mortality despite IABP and inotropic support. Advanced age, heavy inotropic dependency and poor oxygen delivery all predicted increased risk for death. Further investigation is needed to assess whether early institution of VAD support could improve outcome in this high-risk group of patients.
Baskett, Roger J F; O'Connor, Gerald T; Hirsch, Gregory M; Ghali, William A; Sabadosa, Kathy; Morton, Jeremy R; Ross, Cathy S; Hernandez, Felix; Nugent, William C; Lahey, Stephen J; Sisto, Donato A; Dacey, Lawrence J; Klemperer, John D; Helm, Robert E; Maitland, Andrew
2003-12-01
Single-center studies suggest substantial variation in intraaortic balloon pump (IABP) utilization. Our purpose is to examine IABP utilization over time and across medical centers. This was a prospective cohort of 29,961 consecutive patients undergoing isolated coronary artery bypass graft surgery, between 1995 and 2000, at 10 centers (eight in northern New England and two in Canada). A total of 2,678 (8.9%) patients received an IABP. The rate of preoperative IABP insertion was 6.3%, and that of intra- or postoperative insertion was 2.6%. During the 6 years, IABP use increased from 7.0% to 10.3% (p(trend) <0.001). Preoperative IABP insertion increased from 5.4% to 7.8% (p(trend) < 0.001). There was no significant increase in intra-/postoperative IABP insertion 1.7% to 3.4% (p(trend) = 0.34). Adjustment for changes in patient and disease characteristics did not substantially alter these results. The rate of IABP use varied substantially by center, from 5.9% to 16.4% (p < 0.001). Adjustment for patient and disease characteristics resulted in variation from 4.8% to 12.8% across the 10 centers (p < 0.001). The adjusted rates of preoperative IABP insertion varied from 3.6% to 13.7% (p < 0.001), and the rates of intra-/postoperative IABP insertion ranged from 1.0% to 5.2% (p < 0.001). There was no significant correlation between the rates of preoperative and intra-/postoperative IABP use (r(s) = 0.085, p = 0.815). During the 6 years, there was a 47% increase in the rate of IABP utilization. Even after adjustment, there was almost threefold variation in IABP use across centers. This variation likely reflects lack of consensus on the appropriate use of the IABP in CABG patients.
Patel, Hiren; Shivaraju, Anupama; Fonarow, Gregg C.; Xie, Hui; Gao, Weihua; Shroff, Adhir R.; Vidovich, Mladen I.
2014-01-01
Background With conflicting evidence regarding the usefulness of intra-aortic balloon pump (IABP), reports of IABP use in the United States (US) have been inconsistent. Our objective was to examine trends in IABP usage in percutaneous coronary intervention (PCI) in the US, and to evaluate the association of IABP use with mortality. Methods Retrospective, observational study using patient data obtained from the Nationwide Inpatient Sample (NIS) database from 1998 to 2008. Patients undergoing any PCI (1,552,602 procedures) for a primary diagnosis of symptomatic coronary artery disease (CAD) and acute coronary syndrome (ACS), including non-ST elevation MI (NSTEMI) and ST elevation MI (STEMI), were evaluated. Results The overall use of IABP significantly decreased during the study period from 0.99% in 1998 to 0.36% in 2008 (univariate and multivariate p for trend <.0001). Patients who received IABP had substantially higher rates of shock compared to those who did not receive IABP (38.09% vs. 0.70%, p<.0001), which was associated with markedly higher in-hospital mortality rates (20.31% vs. 0.72%, p<.0001). However, IABP use significantly decreased in patients with shock (36.5% to 13.4%) and AMI (2.23% to 0.84%) (univariate and multivariate p for trend for both <.0001). A temporal reduction in all-cause PCI-associated mortality from 1.1% in 1998 to 0.86% in 2008 (univariate and multivariate p for trend <.0001) was also observed. Conclusions The utilization of IABP associated with PCI significantly decreased between 1998 and 2008 in the US, even amongst patients with acute myocardial infarction and shock. PMID:25173549
Minich, L L; Tani, L Y; Pantalos, G M; Bolland, B L; Knorr, B K; Hawkins, J A
1998-11-01
Pediatric intraaortic balloon pumping (IABP) has met with little success because of technical difficulty in tracking rapid heart rates. This study was designed to evaluate the efficacy of M-mode echocardiography for IABP timing in a neonatal piglet model. Two groups of piglets underwent mitral valve avulsion to create a model of shock. Group 1 (n = 8; mean weight, 7.7+/-1.8 kg) underwent IABP timed with both the ascending aortic pressure and M-mode echocardiogram. Group 2 (n = 6; mean weight, 7.5+/-1.4 kg) underwent two separate periods of IABP: one with echocardiographic timing and the second using standard timing points from the femoral arterial pressure tracing and electrocardiogram. Measurements included ascending aortic flow, left anterior descending arterial flow, ascending aortic pressure, left atrial pressure, and heart rate. Mitral valve avulsion produced a shock model with a significant decrease in mean aortic pressure and aortic flow and a significant increase in left atrial pressure and heart rate. Compared with the shock state, IABP in group 1 animals resulted in a significant increase in aortic flow (353+/-152 versus 454+/-109 mL/min; p < 0.05) and a significant decrease in left atrial pressure (23+/-6 versus 17+/-7 mm Hg; p < 0.05). Group 2 animals with echocardiogram-timed IABP had significantly increased aortic flow (365+/-106 versus 458+/-107 mL/min; p < 0.05) and mean aortic pressure (43+/-11 versus 52+/-8 mm Hg; p < 0.05). However, standard-timed IABP failed to show any improvement. In piglets with rapid heart rates, echocardiogram-timed IABP results in increased aortic flow and pressure and decreased left atrial pressure compared with standard-timed IABP.
Wan, You-Dong; Sun, Tong-Wen; Kan, Quan-Cheng; Guan, Fang-Xia; Liu, Zi-Qi; Zhang, Shu-Guang
2016-01-01
Background Intra-aortic balloon pumps (IABP) have generally been used for patients undergoing high-risk mechanical coronary revascularization. However, there is still insufficient evidence to determine whether they can improve outcomes in reperfusion therapy patients, mainly by percutaneous coronary intervention (PCI) with stenting or coronary artery bypass graft (CABG). This study was designed to determine the difference between high-risk mechanical coronary revascularization with and without IABPs on mortality, by performing a meta-analysis on randomized controlled trials of the current era. Methods Pubmed and Embase databases were searched from inception to May 2015. Unpublished data were obtained from the investigators. Randomized clinical trials of IABP and non-IABP in high-risk coronary revascularization procedures (PCI or CABG) were included. In the case of PCI procedures, stents should be used in more than 80% of patients. Numbers of events at the short-term and long-term follow-up were extracted. Results A total of 12 randomized trials enrolling 2155 patients were included. IABPs did not significantly decrease short-term mortality (relative risk (RR) 0.66; 95% CI, 0.42–1.01), or long-term mortality (RR 0.79; 95% CI, 0.47–1.35), with low heterogeneity across the studies. The findings remained stable in patients with acute myocardial infarction with or without cardiogenic shock. But in high-risk CABG patients, IABP was associated with reduced mortality (71 events in 846 patients; RR 0.40; 95%CI 0.25–0.67). Conclusion In patients undergoing high-risk coronary revascularization, IABP did not significantly decrease mortality. But high-risk CABG patients may be benefit from IABP. Rigorous criteria should be applied to the use of IABPs. PMID:26784578
Miceli, Antonio; Duggan, Simon M J; Capoun, Radek; Romeo, Francesco; Caputo, Massimo; Angelini, Gianni D
2010-08-01
There is no accepted consensus on the definition of high-risk patients who may benefit from the use of intraaortic balloon pump (IABP) in coronary artery bypass grafting (CABG). The aim of this study was to develop a risk model to identify high-risk patients and predict the need for IABP insertion during CABG. From April 1996 to December 2006, 8,872 consecutive patients underwent isolated CABG; of these 182 patients (2.1%) received intraoperative or postoperative IABP. The scoring risk model was developed in 4,575 patients (derivation dataset) and validated on the remaining patients (validation dataset). Predictive accuracy was evaluated by the area under the receiver operating characteristic curve. Mortality was 1% in the entire cohort and 18.7% (22 patients) in the group which received IABP. Multivariable analysis showed that age greater than 70 years, moderate and poor left ventricular dysfunction, previous cardiac surgery, emergency operation, left main disease, Canadian Cardiovascular Society 3-4 class, and recent myocardial infarction were independent risk factors for the need of IABP insertion. Three risk groups were identified. The observed probability of receiving IABP and mortality in the validation dataset was 36.4% and 10% in the high-risk group (score >14), 10.9% and 2.8% in the medium-risk group (score 7 to 13), and 1.7% and 0.7% in the low-risk group (score 0 to 6). This simple clinical risk model based on preoperative clinical data can be used to identify high-risk patients who may benefit from elective insertion of IABP during CABG. Copyright 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Altayyar, Sultan; Al-Omari, Awad; Alqahtani, Abdulrahman M; Rochwerg, Bram; Alnasser, Sami; Alqahtani, Zuhoor; Fox-Robichaud, Alison; Alhazzani, Waleed
2015-01-01
Cardiogenic shock is associated with significant mortality, particularly when caused by myocardial infarction. Intraaortic balloon pump (IABP) is the primary hemodynamic adjunct in patients with cardiogenic shock; however, evidence suggests that IABP may not improve mortality in this population. We conducted an electronic search of the Medline, EMBASE, and Cochrane trial registry databases. Two reviewers independently screened citations and identified eligible trials. The same reviewers abstracted data independently. We pooled the data using a fixed effect model and reported dichotomous outcomes as risk ratios (RRs) with 95% confidence intervals (CIs). Subsequently, we used the GRADE approach to judge the quality of evidence. We included 4 randomized trials with 735 patients. The use of IABP did not reduce the risk of death in patients with cardiogenic shock secondary to cardiac ischemia when compared with usual care (RR, 0.94; 95% CI, 0.79-1.13; P = 0.52; I² = 0%; moderate confidence). The use of IABP was not associated with an increased risk of stroke (RR, 0.77; 95% CI 0.22-2.69; P = 0.68; I² = 48%; very low confidence), limb ischemia (RR, 1.24; 95% CI, 0.59-2.59; P = 0.58; I² = 0%; low confidence), or major bleeding (RR, 0.76; 95% CI, 0.34-1.72; P = 0.52; I² = 0%; low confidence). The use of IABP in patients with cardiogenic shock complicating myocardial ischemia does not reduce mortality (moderate confidence) and is not associated with a higher risk of complications (very low to low confidence). The results should be interpreted with caution owing to limitations such as imprecision, risk of bias, and clinical heterogeneity.
1980-02-28
containing a command receiver, batteries, and a differential- pressure switch , all located immediately below the confluence point, with long leads and a...should break free, or during normal deflation at take- down. Purpose of the differential- pressure switch was to momentarily open the valves if the...otherwise was completely different. A differential- pressure switch of the type formerly used in the command package, but without the long pressure
[Obstruction of the nasal passage caused by a balloon catheter in a calf].
Rijkenhuizen, A B
1993-01-01
Decompression of the rumen as a supporting symptomatic therapy of recurrent bloat in calves and juvenile cattle is used regularly. The gas should be released for several days. This is facilitated by the use of a balloon stomach tube, which can be left in situ for up to five days. However, the use of this tube is not always without risks, which will be discussed on base of a patient.
A seal-less centrifugal pump (Baylor Gyro Pump) for application to long-term circulatory support.
Minato, N; Sakuma, I; Sasaki, T; Shiono, M; Ohara, Y; Takatani, S; Noon, G P; Nosé, Y
1993-01-01
We are developing a new centrifugal pump, the Baylor Gyro Centrifugal Pump (Gyro Pump), which can function for more than 2 weeks. The concept of the Gyro Pump is that a one-piece rotor-impeller with embedded permanent magnets, driven directly by a brushless direct current motor stator placed outside, rotates like a "gyroscope," and the rotor-impeller is supported by one pivot bearing at the bottom in accordance with the gyroscopic principle. This concept enables us to eliminate a driving shaft and a seal between the driving shaft and the blood chamber, which results in extending the life of the centrifugal pump. The blood passes through the space between the motor stator and the rotor to the impeller portion. In this preliminary phase, two pivot bearings were applied to support the rotor-impeller at the top and the bottom inside the blood chamber. Both pivot bearings showed less blood trauma and less thrombogenicity in in vitro and in vivo studies. The Gyro Pump is a promising second-generation centrifugal pump for long-term circulatory support in the near future.
Clinical Alarms in intensive care: implications of alarm fatigue for the safety of patients1
Bridi, Adriana Carla; Louro, Thiago Quinellato; da Silva, Roberto Carlos Lyra
2014-01-01
OBJECTIVES: to identify the number of electro-medical pieces of equipment in a coronary care unit, characterize their types, and analyze implications for the safety of patients from the perspective of alarm fatigue. METHOD: this quantitative, observational, descriptive, non-participatory study was conducted in a coronary care unit of a cardiology hospital with 170 beds. RESULTS: a total of 426 alarms were recorded in 40 hours of observation: 227 were triggered by multi-parametric monitors and 199 were triggered by other equipment (infusion pumps, dialysis pumps, mechanical ventilators, and intra-aortic balloons); that is an average of 10.6 alarms per hour. CONCLUSION: the results reinforce the importance of properly configuring physiological variables, the volume and parameters of alarms of multi-parametric monitors within the routine of intensive care units. The alarms of equipment intended to protect patients have increased noise within the unit, the level of distraction and interruptions in the workflow, leading to a false sense of security. PMID:25591100
Chang, Jung-Jung; Lin, Ming-Shyan; Chen, Tien-Hsing; Chen, Dong-Yi; Chen, Shao-Wei; Hsu, Jen-Te; Wang, Po-Chang; Lin, Yu-Sheng
2017-01-01
Background The correlation between severity and long-term outcomes of pediatric myocarditis have been reported, however this correlation in adults has rarely been studied. Materials and Methods This nationwide population-based cohort study used data from the National Health Insurance Research Database in Taiwan. Patients aged < 75 and > 18 years admitted to an intensive care unit due to acute myocarditis were enrolled and divided into three groups according to mechanical circulatory support (MCS) after excluding major comorbidities. All-cause mortality, cardiovascular death, and heart failure hospitalization were evaluated from January 1, 2001 to December 31, 2011. Results There were 1145 patients with acute myocarditis (mean age 40.2 years, SD: 14.8 years), of which 851 did not require MCS, 99 underwent intra-aortic balloon pump (IABP) support, and 195 extracorporeal membrane oxygenation (ECMO) support. There was no significant difference in heart failure hospitalization between the three groups after index admission. The incidence of cardiovascular death after discharge ranged from 10 % to 22%, which was highest in the ECMO group, and was also significantly different between the three groups within 3 months (p<0.001) but it disappeared after 3 months (p=0.458). The trend was also noted in incidence of all-cause mortality. Conclusions The severity of acute myocarditis did not affect long-term outcomes, however, it was associated with cardiovascular/all-cause death within 3 months after discharge. PMID:29104480
Bartoli, Carlo R.; Koenig, Steven C.; Ionan, Constantine; Gillars, Kevin J.; Mitchell, Mike E.; Austin, Erle H.; Gray, Laman A.; Pantalos, George M.
2014-01-01
OBJECTIVE Despite progress with adult ventricular assist devices (VADs), limited options exist to support pediatric patients with life-threatening heart disease. Extracorporeal membrane oxygenation (ECMO) remains the clinical standard. To characterize (patho)physiologic responses to different modes of mechanical unloading of the failing pediatric heart, ECMO was compared to either intraaortic balloon pump (IABP), pulsatile-flow (PF)VAD, or continuous-flow (CF)VAD support in a pediatric heart failure model. DESIGN Experimental. SETTING Large animal laboratory operating room. SUBJECTS Yorkshire piglets (n=47, 11.7±2.6 kg). INTERVENTIONS In piglets with coronary ligation-induced cardiac dysfunction, mechanical circulatory support devices were implanted and studied during maximum support. MEASUREMENTS and MAIN RESULTS Left ventricular, right ventricular, coronary, carotid, systemic arterial, and pulmonary arterial hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption and total-body oxygen consumption (VO2) were calculated from arterial, venous, and coronary sinus blood sampling. Blood flow was measured in 17 organs with microspheres. Paired student t-tests compared baseline and heart failure conditions. One-way repeated-measures ANOVA compared heart failure, device support mode(s), and ECMO. Statistically significant (p<0.05) findings included: 1) improved left ventricular blood supply/demand ratio during PFVAD, CFVAD, and ECMO but not IABP support, 2) improved global myocardial blood supply/demand ratio during PFVAD, and CFVAD but not IABP or ECMO support, and 3) diminished pulsatility during ECMO and CFVAD but not IABP and PFVAD support. A profile of systems-based responses was established for each type of support. CONCLUSIONS Each type of pediatric VAD provided hemodynamic support by unloading the heart with a different mechanism that created a unique profile of physiological changes. These data contribute novel, clinically relevant insight into pediatric mechanical circulatory support and establish an important resource for pediatric device development and patient selection. PMID:24108116
Use of Inotropic Agents in Treatment of Systolic Heart Failure.
Tariq, Sohaib; Aronow, Wilbert S
2015-12-04
The most common use of inotropes is among hospitalized patients with acute decompensated heart failure, with reduced left ventricular ejection fraction and with signs of end-organ dysfunction in the setting of a low cardiac output. Inotropes can be used in patients with severe systolic heart failure awaiting heart transplant to maintain hemodynamic stability or as a bridge to decision. In cases where patients are unable to be weaned off inotropes, these agents can be used until a definite or escalated supportive therapy is planned, which can include coronary revascularization or mechanical circulatory support (intra-aortic balloon pump, extracorporeal membrane oxygenation, impella, left ventricular assist device, etc.). Use of inotropic drugs is associated with risks and adverse events. This review will discuss the use of the inotropes digoxin, dopamine, dobutamine, norepinephrine, milrinone, levosimendan, and omecamtiv mecarbil. Long-term inotropic therapy should be offered in selected patients. A detailed conversation with the patient and family shall be held, including a discussion on the risks and benefits of use of inotropes. Chronic heart failure patients awaiting heart transplants are candidates for intravenous inotropic support until the donor heart becomes available. This helps to maintain hemodynamic stability and keep the fluid status and pulmonary pressures optimized prior to the surgery. On the other hand, in patients with severe heart failure who are not candidates for advanced heart failure therapies, such as transplant and mechanical circulatory support, inotropic agents can be used for palliative therapy. Inotropes can help reduce frequency of hospitalizations and improve symptoms in these patients.
Brunetti, Natale Daniele; Di Pietro, Gaetano; Aquilino, Ambrogio; Bruno, Angela I; Dellegrottaglie, Giulia; Di Giuseppe, Giuseppe; Lopriore, Claudio; De Gennaro, Luisa; Lanzone, Saverio; Caldarola, Pasquale; Antonelli, Gianfranco; Di Biase, Matteo
2014-09-01
We report the preliminary data from a regional registry on ST-elevation myocardial infarction (STEMI) patients treated with primary angioplasty in Apulia, Italy; the region is covered by a single public health-care service, a single public emergency medical service (EMS), and a single tele-medicine service provider. Two hundred and ninety-seven consecutive patients with STEMI transferred by regional free public EMS 1-1-8 for primary-PCI were enrolled in the study; 123 underwent pre-hospital electrocardiograms (ECGs) triage by tele-cardiology support and directly referred for primary-PCI, those remaining were just transferred by 1-1-8 ambulances for primary percutaneous coronary intervention (PCI) (diagnosis not based on tele-medicine ECG; already hospitalised patients, emergency-room without tele-medicine support). Time from first ECG diagnostic for STEMI to balloon was recorded; a time-to-balloon <1 h was considered as optimal and patients as timely treated. Mean time-to-balloon with pre-hospital triage and tele-cardiology ECG was significantly shorter (0:41 ± 0:17 vs 1:34 ± 1:11 h, p<0.001, -0:53 h, -56%) and rates of patients timely treated higher (85% vs 35%, p<0.001, +141%), both in patients from the 'inner' zone closer to PCI catheterisation laboratories (0:34 ± 0:13 vs 0:54 ± 0:30 h, p<0.001; 96% vs 77%, p<0.01, +30%) and in the 'outer' zone (0:52 ± 0:17 vs 1:41 ± 1:14 h, p<0.001; 69% vs 29%, p<0.001, +138%). Results remained significant even after multivariable analysis (odds ratio for time-to-balloon 0.71, 95% confidence interval (CI) 0.63-0.80, p<0.001; 1.39, 95% CI 1.25-1.55, p<0.001, for timely primary-PCI). Pre-hospital triage with tele-cardiology ECG in an EMS registry from an area with more than one and a half million inhabitants was associated with shorter time-to-balloon and higher rates of timely treated patients, even in 'rural' areas. © The European Society of Cardiology 2014.
Alien crop circle? No, that’s just NASA’s newest balloon launch pad
2017-12-08
Aviators, skydivers and other altitude-seeking enthusiasts flying out of Wanaka Airport, New Zealand, are double taking at a new topographical feature reminiscent of an alien crop circle. Rest assured, the nearly 2,000-foot (600-meter) diameter circle with a pie-shaped wedge on one side and spokes on the other is no extraterrestrial footprint and it’s definitely no hoax. It’s NASA’s newest launch pad for launching the agency’s most advanced high-altitude, heavy-lift scientific balloon: the super pressure balloon. The four spokes emanating from the center and toward the west, each nearly 1,000 feet (300 meters) long, align with magnetic compass directions at 240, 260, 290 and 320 degrees. On launch day, balloon flight experts from NASA’s Columbia Scientific Balloon Facility will assess meteorological data and determine if the conditions are suitable to support a launch opportunity. The new pad is the first major project in developing a long-term super pressure balloon launch site in Wanaka. Earlier in 2017, NASA signed a 10-year lease with the Queenstown Airport Corporation to conduct balloon operations from a newly acquired piece of land adjacent to the Wanaka Airport. Credit: NASA/Dave Webb NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Balloons on Ice: NASA Launches Antarctica Scientific Balloon Campaign
2017-12-08
Cosmic rays and the chemicals and atoms that make up the interstellar space between stars are the focus of this year’s NASA Antarctica Long Duration Balloon Flight Campaign, which kicked into high gear with the launch of the Boron And Carbon Cosmic rays in the Upper Stratosphere (BACCUS) payload Nov. 28. The University of Maryland’s BACCUS mission is the first of three payloads taking flight from a balloon launch site on Antarctica’s Ross Ice Shelf near McMurdo Station with support from the National Science Foundation’s United States Antarctic Program. Read more: go.nasa.gov/2gCMtyP NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
NASA Technical Reports Server (NTRS)
1992-01-01
The objectives, status, and accomplishments of the research tasks supported under the NASA Upper Atmosphere Research Program (UARP) are presented. The topics covered include the following: balloon-borne in situ measurements; balloon-borne remote measurements; ground-based measurements; aircraft-borne measurements; rocket-borne measurements; instrument development; reaction kinetics and photochemistry; spectroscopy; stratospheric dynamics and related analysis; stratospheric chemistry, analysis, and related modeling; and global chemical modeling.
Bramlage, Peter; Strauch, Justus; Schröfel, Holger
2014-11-18
In patients with severe calcific aortic stenosis, balloon aortic valvuloplasty (BAV) is routinely performed in order to pre-dilate the stenosed aortic valve prior to transcatheter aortic valve implantation (TAVI). Although pre-dilation is considered to be essential for the preparation of the valve landing zone, there is no clear evidence to support its clinical value. In contrast, BAV has been suggested to be linked to several complications. Notably, while preliminary evidence has supported the feasibility and safety of TAVI without pre-dilation, larger studies directly comparing the benefit/risk profile of TAVI in the presence and absence of pre-dilation are required. Therefore, a prospective, two-armed, multicenter registry (EASE-IT) was designed to obtain essential data concerning procedural success rates, adverse events, and mortality in a large cohort of patients undergoing transapical (TA)-TAVI using the Edwards SAPIEN 3 balloon expandable heart valves with and without pre-ballooning. Data provided by EASE-IT will be used to assess the relevance of BAV during the TAVI procedure and to investigate associations between patient characteristics and outcomes. Therefore, results obtained from the EASE-IT registry could contribute to reduced rates of TAVI-associated morbidity and mortality in patients with severe, calcific aortic stenosis. ClinicalTrials.gov Identifier: NCT02127580.
Design and evaluation of a single-pivot supported centrifugal blood pump.
Yoshino, M; Uemura, M; Takahashi, K; Watanabe, N; Hoshi, H; Ohuchi, K; Nakamura, M; Fujita, H; Sakamoto, T; Takatani, S
2001-09-01
In order to develop a centrifugal blood pump that meets the requirements of a long-term, implantable circulatory support device, in this study a single-pivot bearing supported centrifugal blood pump was designed to evaluate its basic performance. The single-pivot structure consisted of a ceramic ball male pivot mounted on the bottom surface of the impeller and a polyethylene female pivot incorporated in the bottom pump casing. The follower magnet mounted inside the impeller was magnetically coupled to the driver magnet mounted on the shaft of the direct current brushless motor. As the motor rotated, the impeller rotated supported entirely by a single-pivot bearing system. The static pump performance obtained in the mock circulatory loop revealed an acceptable performance as a left ventricular assist device in terms of flow and head pressure. The pump flow of 5 L/min against the head pressure of 100 mm Hg was obtained at rotational speeds of 2,000 to 2,200 rpm. The maximum pump flow was 9 L/min with 2,200 rpm. The maximum electrical-to-hydraulic power conversion efficiency was around 14% at pump flows of 4 to 5 L/min. The stability of the impeller was demonstrated at the pump rpm higher than 1,400 with a single-pivot bearing without an additional support at its top. The single-pivot supported centrifugal pump can provide adequate flow and pressure as a ventricular assist device, but its mechanical stability and hemolytic as well as thrombotic performances must be tested prior to clinical use.
NASA Astrophysics Data System (ADS)
Nott, Julian
This paper will describe practical work flying prototype balloons in the "The Titan Sky Simulator TM " in conditions approximating those found in Titan's atmosphere. Saturn's moon, Titan, is attracting intense scientific interest. This has led to wide interest in exploring it with Aerobots, balloons or airships. Their function would be similar to the Rovers exploring Mars, but instead of moving laboriously across the rough terrain on wheels, they would float freely from location to location. To design any balloon or airship it is essential to know the temperature of the lifting gas as this influences the volume of the gas, which in turn influences the lift. To determine this temperature it is necessary to know how heat is transferred between the craft and its surroundings. Heat transfer for existing balloons is well understood. However, Titan conditions are utterly different from those in which balloons have ever been flown, so heat transfer rates cannot currently be calculated. In particular, thermal radiation accounts for most heat transfer for existing balloons but over Titan heat transfer will be dominated by convection. To be able to make these fundamental calculations, it is necessary to get fundamental experimental data. This is being obtained by flying balloons in a Simulator filled with nitrogen gas at very low temperature, about 95° K / minus 180° C, typical of Titan's temperatures. Because the gas in the Simulator is so cold, operating at atmospheric pressure the density is close to that of Titan's atmosphere. "The Titan Sky Simulator TM " has an open interior approximately 4.5 meter tall and 2.5 meters square. It has already been operated at 95° K/-180° C. By the time of the Conference it is fully expected to have data to present from actual balloons flying at this temperature. Perhaps the most important purpose of this testing is to validate numerical [computational fluid dynamics] models being developed by Tim Colonius of Caltech. These numerical models will be very valuable: once validated, a wide range of Titan aerobot designs can be analyzed rapidly. It is currently expected that Montgolfiere balloons ["hot air balloons"] will prove most suitable for Titan. However, the fundamental data obtained will be equally valuable for designing of any type of Titan Aerobot. This work is supported by the NASA Jet Propulsion Laboratory with Jeffrey Hall as program manager.
A numerical analysis of the aortic blood flow pattern during pulsed cardiopulmonary bypass.
Gramigna, V; Caruso, M V; Rossi, M; Serraino, G F; Renzulli, A; Fragomeni, G
2015-01-01
In the modern era, stroke remains a main cause of morbidity after cardiac surgery despite continuing improvements in the cardiopulmonary bypass (CPB) techniques. The aim of the current work was to numerically investigate the blood flow in aorta and epiaortic vessels during standard and pulsed CPB, obtained with the intra-aortic balloon pump (IABP). A multi-scale model, realized coupling a 3D computational fluid dynamics study with a 0D model, was developed and validated with in vivo data. The presence of IABP improved the flow pattern directed towards the epiaortic vessels with a mean flow increase of 6.3% and reduced flow vorticity.
Totally normothermic aortic arch replacement without circulatory arrest.
Touati, Gilles D; Marticho, Paul; Farag, Moataz; Carmi, Doron; Szymanski, Catherine; Barry, Misbaou; Trojette, Faouzi; Caus, Thierry
2007-08-01
Various techniques have been proposed for cerebral protection during the surgical treatment of complex aortic disease. The authors propose a revisited strategy of normothermic replacement of the aortic arch to avoid limitations and complications of profound hypothermic circulatory arrest. From April 2000 to May 2006, 19 patients with an aneurysm of the aortic arch and 10 patients with an acute (7) or a chronic (3) aortic dissection underwent a totally normothermic, complete replacement of the aortic arch using three pumps: One pump ensured antegrade cerebral perfusion, at a flow rate adapted to obtain a pressure of 70 mmHg in the right radial artery, and required a selective cannulation of the supra-aortic vessels. A second pump ensured body perfusion at a flow rate adapted to obtain a pressure of 55 mmHg in the left femoral artery and was situated between the right femoral artery and the right atrium. A special balloon aortic occlusion catheter was placed in the descending thoracic aorta. A third pump ensured intermittent normothermic myocardial perfusion via the coronary venous sinus. The arch reconstruction was performed with no time limit. There were two operative, in-hospital (6.8%) mortalities. All others patients were rapidly extubated, except one, with no neurological sequelae, and postoperative course was uneventful, without coagulopathy or hepato-renal impairment. In the light of these results, a normothermic procedure is possible for arch surgery and may ensure a more physiological autoregulation of cerebral blood flow while maintaining body perfusion without high vascular resistances.
Drakos, Stavros G; Charitos, Christos E; Ntalianis, Argirios; Terrovitis, John V; Siafakas, Kostas X; Dolou, Paraskevi; Pierrakos, Charalampos; Charitos, Efstratios; Karelas, John; Nanas, John N
2005-01-01
The aim of this study was to examine whether pulsatility by intraaortic balloon counterpulsation (IABP) is an important adjunct to the treatment of profound cardiogenic shock (CS) with a widely used, nonpulsatile centrifugal pump (CP). In each of 18 anesthetized, open chest pigs, the outflow cannula of the CP was inserted in the aortic arch through the right external carotid artery, and the inflow cannula of the CP was placed in the left atrium. A 40 cc IABP was subsequently placed in the descending aorta through the left external carotid artery. CS was induced by occlusion of coronary arteries and the infusion of propranolol and crystalloid fluid. Mean aortic pressure, pulse pressure, aortic end diastolic pressure, left ventricular end diastolic pressure, right atrial pressure, and heart rate were monitored. Cardiac output and left anterior descending artery flow were measured with a transit time ultrasound flowmeter. During profound CS, life sustaining hemodynamics were maintained only with the support of the assist devices. Hemodynamic support with the CP was associated with a nearly nonpulsatile flow and a pulse pressure of 7 +/- 4 mm Hg, which increased to 33 +/- 10 mm Hg (p = 0.000) after combining the CP with the IABP. Compared with the hemodynamic support offered by the CP alone, addition of the IABP increased mean aortic pressure from 40 +/- 15 to 50 +/- 16 mm Hg (p = 0.000), cardiac output from 810 +/- 194 to 1,200 +/- 234 ml/min (p = 0.003), and left anterior descending artery flow from 26 +/- 10 to 39 +/- 14 ml/min (p = 0.001). In profound CS, mechanical support provided by a continuous flow CP is enhanced by the added pulsatility of the IABP.
Kusters, R W J; Simons, A P; Lancé, M D; Ganushchak, Y M; Bekers, O; Weerwind, P W
2017-01-01
Low-flow extracorporeal life support can be used for cardiopulmonary support of paediatric and neonatal patients and is also emerging as a therapy for patients suffering from exacerbation of chronic obstructive pulmonary disease. However, pump heating and haemolysis have proven to negatively affect the system and outcome. This in vitro study aimed at gaining insight into blood warming, pump heating and haemolysis related to the performance of a new low-flow centrifugal pump. Pump performance in the 400-1,500 ml/min flow range was modulated using small-sized dual-lumen catheters and freshly donated human blood. Measurements included plasma free haemoglobin, blood temperature, pump speed, pump pressure, blood flow and thermographic imaging. Blood warming (ΔT max =0.5°C) had no relationship with pump performance or haemolysis (R 2 max =0.05). Pump performance-related parameters revealed no relevant relationships with haemolysis (R 2 max =0.36). Thermography showed no relevant heat zones in the pump (T max =36°C). Concerning blood warming, pump heating and haemolysis, we deem the centrifugal pump applicable for low-flow extracorporeal circulation.
NASA Technical Reports Server (NTRS)
Stuchlik, David W.; Lanzi, Raymond J.
2017-01-01
The National Aeronautics and Space Administrations (NASA) Wallops Flight Facility (WFF), part of the Goddard Space Flight Center (GSFC), has developed a unique pointing control system for instruments aboard scientific balloon gondolas. The ability to point large telescopes and instruments with arc-second accuracy and stability is highly desired by multiple scientific disciplines, such as Planetary, Earth Science, Heliospheric and Astrophysics, and the availability of a standardized system supplied by NASA alleviates the need for the science user to develop and provide their own system. In addition to the pointing control system, a star tracker has been developed with both daytime and nighttime capability to augment the WASP and provide an absolute pointing reference. The WASP Project has successfully completed five test flights and one operational science mission, and is currently supporting an additional test flight in 2017, along with three science missions with flights scheduled between 2018 and 2020. The WASP system has demonstrated precision pointing and high reliability, and is available to support scientific balloon missions.
Ashenhurst, James R; Bujarski, Spencer; Jentsch, J David; Ray, Lara A
2014-08-01
The relationship between risk-taking behavior and substance dependence has proven to be complex, particularly when examining across participants expressing a range of substance use problem severity. While main indices of risk-taking in the Balloon Analogue Risk Task (BART) positively associate with problematic alcohol use in adolescent populations (e.g., MacPherson, Magidson, Reynolds, Kahler, & Lejuez, 2010), several studies have observed a negative relationship when examining behavior within adult substance using populations (Ashenhurst, Jentsch, & Ray, 2011; Campbell, Samartgis, & Crowe, 2013). To examine potential mechanisms that underlie this negative relationship, we implemented multilevel regression models on trial-by-trial BART data gathered from 295 adult problem drinkers. These models accounted for participant behavior on trials following balloon bursts or cash outs as indices of loss and reward reactivity, respectively, and included control variables including age, IQ, and individual delay discounting rate. Results revealed that individual trial pumping was significantly predicted by trial number, and by whether or not the previous trial was a big burst or a big cash out (i.e., large magnitude of potential gains) in a manner consistent with a "near-miss" effect. Furthermore, severity of alcohol problems moderated the effect of a previous trial big burst, but not of a big cash out, on subsequent trial behavior such that those with greater severity demonstrated relative insensitivity to this "near-miss" effect. These results extend previous studies suggesting that alcohol abusers are less risky on the BART by specifying a mechanism underlying this pattern, namely, diminished reactivity to large magnitude losses.
The Extreme Universe Space Observatory Super Pressure Balloon Mission
NASA Astrophysics Data System (ADS)
Wiencke, Lawrence; Olinto, Angela; Adams, Jim; JEM-EUSO Collaboration
2017-01-01
The Extreme Universe Space Observatory on a super pressure balloon (EUSO-SPB) mission will make the first fluorescence observations of high energy cosmic ray extensive air showers by looking down on the atmosphere from near space. A long duration flight of at least 50 nights launched from Wanaka NZ is planned for 2017. We describe completed instrument, and the planned mission. We acknowledge the support of NASA through grants NNX13AH53G and NNX13AH55G.
2005-09-01
employed. This particular balloon design uses a flap, known as a kite , which functions as a sail to increase lift capability and improve airborne...stability. The kite increases the balloon’s lift capability to 800 pounds in 90- knot winds and enables the balloon position to be relatively...Thai airfield at Wing 2. This vehicle may also serve as a runner vehicle for the MCP node of the COASTS demonstration. A PRC-117 will be available
Matsuse, Hiroo; Akimoto, Ryuji; Kamiya, Shiro; Moritani, Toshio; Sasaki, Motoki; Ishizaki, Yuta; Ohtsuka, Masanori; Nakayoshi, Takaharu; Ueno, Takafumi; Shiba, Naoto; Fukumoto, Yoshihiro
2017-01-01
Background The lower limb muscle may play an important role in decreasing the heart’s pumping workload. Aging and inactivity cause atrophy and weakness of the muscle, leading to a loss of the heart-assisting role. An electrical lower limb muscle stimulator can prevent atrophy and weakness more effectively than conventional resistance training; however, it has been reported to increase the heart’s pumping workload in some situations. Therefore, more effective tools should be developed. Methods We newly developed a cardiac cycle-synchronized electrical lower limb muscle stimulator by combining a commercially available electrocardiogram monitor and belt electrode skeletal muscle electrical stimulator, making it possible to achieve strong and wide but not painful muscle contractions. Then, we tested the stimulator in 11 healthy volunteers to determine whether the special equipment enabled lower limb muscle training without harming the hemodynamics using plethysmography and a percutaneous cardiac output analyzer. Results In 9 of 11 subjects, the stimulator generated diastolic augmentation waves on the dicrotic notches and end-diastolic pressure reduction waves on the plethysmogram waveforms of the brachial artery, showing analogous waveforms in the intra-aortic balloon pumping heart-assisting therapy. The heart rate, stroke volume, and cardiac output significantly increased during the stimulation. There was no change in the systolic or diastolic blood pressure during the stimulation. Conclusion Cardiac cycle-synchronized electrical muscle stimulation for the lower limbs may enable muscle training without harmfully influencing the hemodynamics and with a potential to reduce the heart’s pumping workload, suggesting a promising tool for effectively treating both locomotor and cardiovascular disorders. PMID:29117189
Mathematical modelling of flow in disc friction LVAD pump
NASA Astrophysics Data System (ADS)
Medvedev, A. E.; Fomin, V. M.; Prikhodko, Yu. M.; Cherniavskiy, A. M.; Fomichev, V. P.; Fomichev, A. V.; Chekhov, V. P.; Ruzmatov, T. M.
2017-10-01
The need for blood circulation support systems in the treatment of chronic heart failure is constantly increasing as 20% of patients on the waiting list die every year. Despite the great need for mechanical heart support systems the use of available systems is limited by the high cost. Therefore, further research in the field of circulatory support systems is appropriate taking into account medical and technical requirements. One of the new research areas is viscous friction disk pumps for transporting liquids based on the Tesla pump principle. The experimental model of LVAD disk pump is developed. Analytical dependencies are obtained to optimize the hydraulic parameters of the pump. On their basis, the experimental model of LVAD disk pump was designed and created. The results of analytical and experimental studies of such a pump are presented.
NASA Astrophysics Data System (ADS)
Deshler, Terry; Stübi, Rene; Schmidlin, Francis J.; Mercer, Jennifer L.; Smit, Herman G. J.; Johnson, Bryan J.; Kivi, Rigel; Nardi, Bruno
2017-06-01
Ozone plays a significant role in the chemical and radiative state of the atmosphere. For this reason there are many instruments used to measure ozone from the ground, from space, and from balloons. Balloon-borne electrochemical cell ozonesondes provide some of the best measurements of the ozone profile up to the mid-stratosphere, providing high vertical resolution, high precision, and a wide geographic distribution. From the mid-1990s to the late 2000s the consistency of long-term records from balloon-borne ozonesondes has been compromised by differences in manufacturers, Science Pump (SP) and ENSCI (EN), and differences in recommended sensor solution concentrations, 1.0 % potassium iodide (KI) and the one-half dilution: 0.5 %. To investigate these differences, a number of organizations have independently undertaken comparisons of the various ozonesonde types and solution concentrations, resulting in 197 ozonesonde comparison profiles. The goal of this study is to derive transfer functions to allow measurements outside of standard recommendations, for sensor composition and ozonesonde type, to be converted to a standard measurement and thus homogenize the data to the expected accuracy of 5 % (10 %) in the stratosphere (troposphere). Subsets of these data have been analyzed previously and intermediate transfer functions derived. Here all the comparison data are analyzed to compare (1) differences in sensor solution composition for a single ozonesonde type, (2) differences in ozonesonde type for a single sensor solution composition, and (3) the World Meteorological Organization's (WMO) and manufacturers' recommendations of 1.0 % KI solution for Science Pump and 0.5 % KI for ENSCI. From the recommendations it is clear that ENSCI ozonesondes and 1.0 % KI solution result in higher amounts of ozone sensed. The results indicate that differences in solution composition and in ozonesonde type display little pressure dependence at pressures ≥ 30 hPa, and thus the transfer function can be characterized as a simple ratio of the less sensitive to the more sensitive method. This ratio is 0.96 for both solution concentration and ozonesonde type. The ratios differ at pressures < 30 hPa such that OZ0. 5%/OZ1. 0 % = 0. 90 + 0. 041 ṡ log10(p) and OZSciencePump/OZENSCI = 0. 764 + 0. 133 ṡ log10(p) for p in units of hPa. For the manufacturer-recommended solution concentrations the dispersion of the ratio (SP-1.0 / EN-0.5 %), while significant, is generally within 3 % and centered near 1.0, such that no changes are recommended. For stations which have used multiple ozonesonde types with solution concentrations different from the WMO's and manufacturer's recommendations, this work suggests that a reasonably homogeneous data set can be created if the quantitative relationships specified above are applied to the non-standard measurements. This result is illustrated here in an application to the Nairobi data set.
Improving INPE'S balloon ground facilities for operation of the protoMIRAX experiment
NASA Astrophysics Data System (ADS)
Mattiello-Francisco, F.; Rinke, E.; Fernandes, J. O.; Cardoso, L.; Cardoso, P.; Braga, J.
2014-10-01
The system requirements for reusing the scientific balloon ground facilities available at INPE were a challenge to the ground system engineers involved in the protoMIRAX X-ray astronomy experiment. A significant effort on software updating was required for the balloon ground station. Considering that protoMIRAX is a pathfinder for the MIRAX satellite mission, a ground infrastructure compatible with INPE's satellite operation approach would be useful and highly recommended to control and monitor the experiment during the balloon flights. This approach will make use of the SATellite Control System (SATCS), a software-based architecture developed at INPE for satellite commanding and monitoring. SATCS complies with particular operational requirements of different satellites by using several customized object-oriented software elements and frameworks. We present the ground solution designed for protoMIRAX operation, the Control and Reception System (CRS). A new server computer, properly configured with Ethernet, has extended the existing ground station facilities with switch, converters and new software (OPS/SERVER) in order to support the available uplink and downlink channels being mapped to TCP/IP gateways required by SATCS. Currently, the CRS development is customizing the SATCS for the kernel functions of protoMIRAX command and telemetry processing. Design-patterns, component-based libraries and metadata are widely used in the SATCS in order to extend the frameworks to address the Packet Utilization Standard (PUS) for ground-balloon communication, in compliance with the services provided by the data handling computer onboard the protoMIRAX balloon.
Balloon-borne air traffic management (ATM) as a precursor to space-based ATM
NASA Astrophysics Data System (ADS)
Brodsky, Yuval; Rieber, Richard; Nordheim, Tom
2012-01-01
The International Space University—Balloon Air traffic control Technology Experiment (I-BATE ) has flown on board two stratospheric balloons and has tracked nearby aircraft by receiving their Automatic Dependent Surveillance-Broadcast (ADS-B) transmissions. Air traffic worldwide is facing increasing congestion. It is predicted that daily European flight volumes will more than double by 2030 compared to 2009 volumes. ADS-B is an air traffic management system being used to mitigate air traffic congestion. Each aircraft is equipped with both a GPS receiver and an ADS-B transponder. The transponder transmits an equipped aircraft's unique identifier, position, heading, and velocity once per second. The ADS-B transmissions can then be received by ground stations for use in traditional air traffic management. Airspace not monitored by these ground stations or other traditional means remains uncontrolled and poorly monitored. A constellation of space-based ADS-B receivers could close these gaps and provide global air traffic monitoring. By flying an ADS-B receiver on a stratospheric balloon, I-BATE has served as a precursor to a constellation of ADS-B-equipped Earth-orbiting satellites. From the ˜30 km balloon altitude, I-BATE tracked aircraft ranging up to 850 km. The experiment has served as a proof of concept for space-based air traffic management and supports a technology readiness level 6 of space-based ADS-B reception. I-BATE: International Space University—Balloon Air traffic control Technology Experiment.
Benefits, risks, and costs of stratospheric geoengineering
NASA Astrophysics Data System (ADS)
Robock, Alan; Marquardt, Allison; Kravitz, Ben; Stenchikov, Georgiy
2009-10-01
Injecting sulfate aerosol precursors into the stratosphere has been suggested as a means of geoengineering to cool the planet and reduce global warming. The decision to implement such a scheme would require a comparison of its benefits, dangers, and costs to those of other responses to global warming, including doing nothing. Here we evaluate those factors for stratospheric geoengineering with sulfate aerosols. Using existing U.S. military fighter and tanker planes, the annual costs of injecting aerosol precursors into the lower stratosphere would be several billion dollars. Using artillery or balloons to loft the gas would be much more expensive. We do not have enough information to evaluate more exotic techniques, such as pumping the gas up through a hose attached to a tower or balloon system. Anthropogenic stratospheric aerosol injection would cool the planet, stop the melting of sea ice and land-based glaciers, slow sea level rise, and increase the terrestrial carbon sink, but produce regional drought, ozone depletion, less sunlight for solar power, and make skies less blue. Furthermore it would hamper Earth-based optical astronomy, do nothing to stop ocean acidification, and present many ethical and moral issues. Further work is needed to quantify many of these factors to allow informed decision-making.
Coen, S J
2011-06-01
Functional neuroimaging has been used extensively in conjunction with gastric balloon distension in an attempt to unravel the relationship between the brain, regulation of hunger, satiety, and food intake tolerance. A number of researchers have also adopted a more physiological approach using intra-gastric administration of a liquid meal which has revealed different brain responses to gastric balloon distension. These differences are important as they question the utility and relevance of non-physiological models such as gastric balloon distension, especially when investigating mechanisms of feeding behavior such as satiety. However, an assessment of the relevance of physiological versus non-physiological gastric distension has been problematic due to differences in distension volumes between studies. In this issue of Neurogastroenterology and Motility, Geeraerts et al. compare brain activity during volume matched nutrient gastric distension and balloon distension in healthy volunteers. Gastric balloon distension activated the 'visceral pain neuromatrix'. This network of brain regions was deactivated during nutrient infusion, supporting the notion that brain activity during physiological versus non-physiological distension is indeed different. The authors suggest deactivation of the pain neuromatrix during nutrient infusion serves as a prerequisite for tolerance of normal meal volumes in health. © 2011 Blackwell Publishing Ltd.
The X-point effects on the peeling-ballooning stability conditions
NASA Astrophysics Data System (ADS)
Zheng, Linjin
2017-10-01
Due to the X-point singularity the safety factor tends to infinity as the last closed flux surface is approached. The usual numerical treatment of X-point singularity is to cut off a small fraction of edge region for system stability evaluation or simply use an up-down symmetric equilibrium without X-point included. This type of treatments have been used to make the peeling-ballooning stability diagram. We found that the mode types, peel or ballooning, can vary depending on how much the edge portion is cut off. When the cutting-off leads the edge safety factor (qa) to become close to a mode rational number, the peeling modes dominate; otherwise the ballooning type of modes prevail. The stability condition for peeling modes with qa being close to a rational number is much stringent than that for ballooning type of modes. Because qa tends to infinite near the separatrix, the mode rational surfaces are concentrated in the plasma region and thus the peeling modes are basically excluded. This extrapolation indicates that the stability boundary for high edge current, which is related to the peeling modes, need to be reexamined to take into account the X-point effects. Supported by U. S. Department of Energy, Office of Fusion Energy Science: Grant No. DE-FG02-04ER-54742.
Coronary bypass flow during use of intraaortic balloon pumping and left ventricular assist device.
Tedoriya, T; Kawasuji, M; Sakakibara, N; Takemura, H; Watanabe, Y; Hetzer, R
1998-08-01
Intraaortic balloon pumping (IABP) and left ventricular assist device (LVAD) are used for left ventricular support when low cardiac output occurs after a coronary bypass operation for serious coronary artery disease. There are hemodynamic differences in blood flow in various kinds of coronary artery bypass grafts, caused by their inherent physiologic characteristics. The hemodynamic effects of left ventricular assistance with IABP and LVAD on blood flow through various coronary artery bypass grafts were investigated. An ascending aorta-coronary bypass graft (ACB), an internal thoracic artery, and a descending aorta-coronary bypass graft were anastomosed to the left anterior descending coronary artery in a canine model. In this experimental model, the blood flow to the same coronary bed in the three types of grafts could be evaluated. Blood flow in the left anterior descending coronary artery through the three types of coronary bypass grafts was studied in this model during or in the absence of ventricular assistance. In the control study, the systolic blood flow did not differ among the three types of grafts, but the diastolic flow decreased in the following order: with the ACB, the internal thoracic artery, and the descending aorta-coronary bypass graft. The systolic flow during IABP and LVAD was similar to the control flows. Use of IABP increased the diastolic flow by 75.3%+/-12.4% of the control value in the ACB, 37.9%+/-25.0% in the internal thoracic artery, and 21.2%+/-11.4% in the descending aorta-coronary bypass graft. The LVAD increased the diastolic flow by 97.7%+/-18.7% of the control value in the ACB, 64.5%+/-25.7% in the internal thoracic artery, and 63.0%+/-27.9% in the descending aorta-coronary bypass graft. The diastolic blood flows in the left anterior descending coronary artery and the three types of grafts were significantly greater with IABP than the control values, and significantly greater with LVAD than with IABP and the control values. The degrees of increase of diastolic flows in the left anterior descending coronary artery and the ACB with IABP and LVAD were significantly greater than in the arterial grafts (p < 0.01). The diastolic flows in the internal thoracic artery and descending aorta-coronary bypass graft increased less than in the native left anterior descending coronary artery and ACB during left ventricular assistance, particularly with IABP. It is important for the selection of tactics for the management of catastrophic status after coronary bypass grafting to consider the hemodynamic characteristics of the graft.
AIAA Educator Academy: The Space Weather Balloon Module
NASA Astrophysics Data System (ADS)
Longmier, B.; Henriquez, E.; Bering, E. A.; Slagle, E.
2013-12-01
Educator Academy is a K-12 STEM curriculum developed by the STEM K-12 Outreach Committee of the American Institute of Aeronautics and Astronautics (AIAA). Consisting of three independent curriculum modules, K-12 students participate in inquiry-based science and engineering challenges to improve critical thinking skills and enhance problem solving skills. The Space Weather Balloon Curriculum Module is designed for students in grades 9-12. Throughout this module, students learn and refine physics concepts as well as experimental research skills. Students participate in project-based learning that is experimental in nature. Students are engaged with the world around them as they collaborate to launch a high altitude balloon equipped with HD cameras.The program leaders launch high altitude weather balloons in collaboration with schools and students to teach physics concepts, experimental research skills, and to make space exploration accessible to students. A weather balloon lifts a specially designed payload package that is composed of HD cameras, GPS tracking devices, and other science equipment. The payload is constructed and attached to the balloon by the students with low-cost materials. The balloon and payload are launched with FAA clearance from a site chosen based on wind patterns and predicted landing locations. The balloon ascends over 2 hours to a maximum altitude of 100,000 feet where it bursts and allows the payload to slowly descend using a built-in parachute. The payload is located using the GPS device. In April 2012, the Space Weather Balloon team conducted a prototype field campaign near Fairbanks Alaska, sending several student-built experiments to an altitude of 30km, underneath several strong auroral displays. To better assist teachers in implementing one or more of these Curriculum Modules, teacher workshops are held to give teachers a hands-on look at how this curriculum is used in the classroom. And, to provide further support, teachers are each provided with an AIAA professional member as a mentor for themselves and/or their students. These curriculum modules, provided by AIAA are available to any K-12 teachers as well as EPO officers for use in formal or informal education settings.
Costantini, C; Sampaolesi, A; Serra, C M; Pacheco, G; Neuburger, J; Conci, E; Haendchen, R V
1991-07-01
Synchronized coronary venous retroperfusion was used during coronary balloon angioplasty to support the ischemic myocardium of 20 patients with unstable angina and anatomy at high risk of a coronary event. Hemodynamics and left ventricular function were the major end points of the study. Coronary venous catheterization and retroperfusion were successfully performed in 15 patients. The target vessel was an unprotected left main artery in 2, left anterior descending artery in 10, left circumflex coronary artery in 1 and right coronary artery in 2 patients. A nonsupported balloon inflation (mean 44 +/- 13 s) was compared with a later retroperfusion-supported inflation (mean 145 +/- 21 s). Right anterior oblique left ventriculograms, aortic blood pressure, pulmonary artery pressure and thermodilution cardiac output were obtained before and during peak untreated and treated balloon inflations and on completion of angioplasty. All patients had either a baseline left ventricular ejection fraction less than 0.40 or greater than 40% of contracting myocardium estimated to be at risk for severe ischemia during angioplasty. The cardiac (liters/min per m2) and stroke work (g.m/m2) indexes decreased from mean baseline values of 2.5 +/- 0.52 and 52 +/- 15 to 1.7 +/- 0.47 and 27 +/- 12 (mean +/- SD), respectively, during nonsupported balloon inflations but decreased only to 2.1 +/- 0.52 (p less than 0.01 vs. nonsupported) and to 36 +/- 14 (p = 0.01 vs. nonsupported), respectively, during retroperfusion-supported inflations. Ejection fraction (n = 8) decreased from a baseline value of 55 +/- 13% to 27 +/- 7.3% during nonsupported inflations but only to 39 +/- 10% during retroperfusion-supported inflations (p = 0.01 vs. nonsupported). Regional wall motion (area change) in the ischemic (target) region was reduced from a baseline value of 49 +/- 17% to 11 +/- 16% during nonsupported inflations but only to 27 +/- 15% during retroperfusion-supported inflations (p less than 0.01 vs. nonsupported). All but two patients had a favorable hemodynamic response to retroperfusion. There were no serious adverse effects related to the procedures and no hospital deaths. It is concluded from this preliminary study that coronary venous retroperfusion appears to be safe, to provide hemodynamic support and to improve left ventricular function during angioplasty in patients with unstable angina and anatomy at high risk of a coronary event.
High Energy Antimatter Telescope (HEAT) Balloon Experiment
NASA Technical Reports Server (NTRS)
Beatty, J. J.
1995-01-01
This grant supported our work on the High Energy Antimatter Telescope(HEAT) balloon experiment. The HEAT payload is designed to perform a series of experiments focusing on the cosmic ray positron, electron, and antiprotons. Thus far two flights of the HEAT -e+/- configuration have taken place. During the period of this grant major accomplishments included the following: (1) Publication of the first results of the 1994 HEAT-e+/- flight in Physical Review Letters; (2) Successful reflight of the HEAT-e+/- payload from Lynn Lake in August 1995; (3) Repair and refurbishment of the elements of the HEAT payload damaged during the landing following the 1995 flight; and (4) Upgrade of the ground support equipment for future flights of the HEAT payload.
NASA Astrophysics Data System (ADS)
Cocquerez, P.; Venel, S.; Vial, F.; Mechoso, R.; Hertzog, A.; Basdevant, C.
The Stratéole-Vorcore stratospheric balloon campaign took place in September-October 2005 from McMurdo Antarctica This campaign which benefited from a very significant support from the National science Foundation as well as from the French polar institute Institut Paul Emile Victor is a joint effort of the French space agency CNES and the Laboratoire de meteorology Dynamique IPSL CNRS 27 balloons were released from 5 th of September to 28 th of October Drifting during several months at constant air density in the low stratosphere they formed a flotilla of up to 21 balloons floating simultaneously The duration of flight cumulated over the entire flotilla reached 1577 days producing more than 150 000 meteorological observations This presentation will mainly focus on the description of the ground and flight systems the launch operations and the main characteristics of the flights It will be completed by an overview of the current plans for the utilisation of this observation system for other scientific missions in the near future
Crest - A Balloon-borne Instrument To Measure Cosmic-ray Electrons Above TeV Energies.
NASA Astrophysics Data System (ADS)
Schubnell, Michael; Anderson, T.; Bower, C.; Coutu, S.; Geske, M.; Müller, D.; Musser, J.; Nutter, S.; Park, N.; Tarlé, G.; Wakely, S.; Yagi, A.
2009-01-01
The observation of high energy (E > 1 TeV) electrons in the cosmic radiation provides important information on the distribution and energetics of local cosmic-ray sources. Galactic cosmic-ray electrons are thought to be shock accelerated in supernova remnants as evident from observations of non-thermal X-rays and TeV gamma rays. Their locally observed energy spectrum above 1 TeV is expected to reflect the distribution and abundance of nearby acceleration sites. However, the rates at these energies are low and the direct detection would require unfeasibly large balloons or satellite born detectors. CREST, a balloon-borne detector array of 1024 BaF2 crystals, overcomes this hurdle: it will measure the intensity and spectrum of multi-TeV electrons by detecting synchrotron photons emitted from electrons passing through the earth's magnetic field. Thus CREST's acceptance is several times its geometric area providing sensitivity up to about 50 TeV. Following an engineering flight in spring of 2009, CREST will be flown in a circumpolar orbit on an upcoming Antarctic long-duration balloon flight. This work is supported by NASA and CSBF.
High Altitude Balloons as a Platform for Space Radiation Belt Science
NASA Astrophysics Data System (ADS)
Mazzino, L.; Buttenschoen, A.; Farr, Q.; Hodgson, C.; Johnson, W.; Mann, I. R.; Rae, J.; University of Alberta High Altitude Balloons (UA-HAB)
2011-12-01
The goals of the University of Alberta High Altitude Balloons Program (UA-HAB) are to i) use low cost balloons to address space radiation science, and ii) to utilise the excitement of "space mission" involvement to promote and facilitate the recruitment of undergraduate and graduate students in physics, engineering, and atmospheric sciences to pursue careers in space science and engineering. The University of Alberta High Altitude Balloons (UA-HAB) is a unique opportunity for University of Alberta students (undergraduate and graduate) to engage in the hands-on design, development, build, test and flight of a payload to operate on a high altitude balloon at around 30km altitude. The program development, including formal design and acceptance tests, reports and reviews, mirror those required in the development of an orbital satellite mission. This enables the students to gain a unique insight into how space missions are flown. UA-HAB is a one and half year program that offers a gateway into a high-altitude balloon mission through hands on experience, and builds skills for students who may be attracted to participate in future space missions in their careers. This early education will provide students with the experience necessary to better assess opportunities for pursuing a career in space science. Balloons offer a low-cost alternative to other suborbital platforms which can be used to address radiation belt science goals. In particular, the participants of this program have written grant proposal to secure funds for this project, have launched several 'weather balloon missions', and have designed, built, tested, and launched their particle detector called "Maple Leaf Particle Detector". This detector was focussed on monitoring cosmic rays and space radiation using shielded Geiger tubes, and was flown as one of the payloads from the institutions participating in the High Altitude Student Platform (HASP), organized by the Louisiana State University and the Louisiana Space Consortium (LaSpace), and sponsored by NASA. The HASP platform was launched from Fort Sumner, New Mexico, and to an altitude of about 36kilometers with flight durations of 15 to 20 hours using a small volume, low pressure balloon. The main objectives of the program, the challenges involved in developing it, and the major achievements and outcomes will be discussed. Future opportunities for the use of high altitude balloons for solar-terrestrial science, such as the diagnosis of radiation belt loss through the flight of alternative X-ray scintillator payloads, on short duration weather balloon flights will also be discussed. The UA-HAB project is undertaken with the financial support of the Canadian Space Agency.
Gondola development for CNES stratospheric balloons
NASA Astrophysics Data System (ADS)
Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.
The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance (over the line of sight) than with dedicated RF system, which requires balloon visibility from the ground station. For long duration flights (3 months) of Infra Red Montgolfieres, a house keeping gondola has been developed, using the Inmarsat C standard to have communication all around the world (up to N or S 80 ° latitude) with an automatic switching between the 4 geostationnary Inmarsat satellites. After validation flights performed from Bauru / Brazil. (2000 & 2001) and Kiruna/Sweden (2002), the first operational flights took place from Bauru in February 2003 during ENVISAT validation campaign. The next flights will be realized in the framework of the Hibiscus campaign planned in February 2004 in Bauru.. The Balloon Division was involved in the Franco / Japanese HSFD II project which consists to drop a mock-up of the Japanese HOPE-X space shuttle from a stratospheric balloon to validate its flight from the altitude of 30 km. We developed a specific gondola as a service module for the HOPE-X shuttle, providing power and GPS radio-frequency signal during the balloon flight phase, telemetry end remote control radio frequency links and separation system with pyrotechnic cutters for the drop of the shuttle. A successful flight was performed at Kiruna in July 2003. Concerning gondola with pointing system, the study of a big g-ray telescope (8 m of focal length), started by the end of 2002. For this 1 ton gondola, the telescope stabilization system will be based on control moment gyro (CMG). The CMG system has been designed and will be manufactured and validated during 2004. The first flight of this g-ray gondola is planned for 2006. The progress, status and future plans concerning these gondola developments will be presented.
Development of EXITE3, Imaging Detectors and a Long Duration Balloon Gondola
NASA Technical Reports Server (NTRS)
2003-01-01
In this Report we summarize the work conducted for the EXITE program under grant NAG5-5103. This grant supported the ongoing EXITE program at Harvard for the development of imaging hard x-ray detectors and telescopes over the 3 year period 1997-2000 with a one year extension to 2001 to transition to the next SR&T grant in this program. Work was conducted in three major parts: analysis of the EXITE2 balloon flight data (from our May 1997 flight); development of pixellated imaging Cd-Zn-Te detector arrays and readout systems for the proposed EXITE3 detector and telescope; and development of systems for a Long Duration Balloon (LDB) gondola. Progress on all three major aspects of this research is summarized for each of the years of this grant.
Sonic Thermometer for High-Altitude Balloons
NASA Technical Reports Server (NTRS)
Bognar, John
2012-01-01
The sonic thermometer is a specialized application of well-known sonic anemometer technology. Adaptations have been made to the circuit, including the addition of supporting sensors, which enable its use in the high-altitude environment and in non-air gas mixtures. There is a need to measure gas temperatures inside and outside of superpressure balloons that are flown at high altitudes. These measurements will allow the performance of the balloon to be modeled more accurately, leading to better flight performance. Small thermistors (solid-state temperature sensors) have been used for this general purpose, and for temperature measurements on radiosondes. A disadvantage to thermistors and other physical (as distinct from sonic) temperature sensors is that they are subject to solar heating errors when they are exposed to the Sun, and this leads to issues with their use in a very high-altitude environment
Cryo-balloon catheter position planning using AFiT
NASA Astrophysics Data System (ADS)
Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert
2012-02-01
Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.
Selection of radio sources for Venus balloon-Pathfinder Delta-DOR navigation at 1.7 GHz
NASA Technical Reports Server (NTRS)
Liewer, K. M
1986-01-01
In order to increase the success rate of the Delta-DOR (Delta-Differential One-way Range) VLBI navigational support for the French-Soviet Venus Balloon and Halley Pathfinder projects, forty-four extragalactic radio sources were observed in advance of these projects to determine which were suitable for use as reference sources. Of these forty-four radio sources taken from the existing JPL radio source catalogue, thirty-six were determined to be of sufficient strength for use in Delta-DOR VLBI navigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alexander Pigarov
2012-06-05
This is the final report for the Research Grant DE-FG02-08ER54989 'Edge Plasma Simulations in NSTX and CTF: Synergy of Lithium Coating, Non-Diffusive Anomalous Transport and Drifts'. The UCSD group including: A.Yu. Pigarov (PI), S.I. Krasheninnikov and R.D. Smirnov, was working on modeling of the impact of lithium coatings on edge plasma parameters in NSTX with the multi-species multi-fluid code UEDGE. The work was conducted in the following main areas: (i) improvements of UEDGE model for plasma-lithium interactions, (ii) understanding the physics of low-recycling divertor regime in NSTX caused by lithium pumping, (iii) study of synergistic effects with lithium coatings andmore » non-diffusive ballooning-like cross-field transport, (iv) simulation of experimental multi-diagnostic data on edge plasma with lithium pumping in NSTX via self-consistent modeling of D-Li-C plasma with UEDGE, and (v) working-gas balance analysis. The accomplishments in these areas are given in the corresponding subsections in Section 2. Publications and presentations made under the Grant are listed in Section 3.« less
Preliminary clinical investigations of a new noninvasive venous pulse oximeter
NASA Astrophysics Data System (ADS)
Chan, Daniel; Smith, Peter R.; Caine, Michael P.; Spyt, Tomasz; Boehm, Maria; Machin, David
2003-10-01
For decades, the monitoring of mixed venous oxygen saturation, SvO2 has been performed invasively using fibre-optic catheters. This procedure is not without risk as complications may arise from catheterisation. The group has devised a new non-invasive venous oximetry method which involves inducing regular modulations of the venous blood volume and associated measurement of those modulations using optical means. A clinical investigation was conducted in Glenfield Hospital, UK to evaluate the sensitivity of the new technique to haemodynamic changes such as Cardiac Output (CO) in intraoperative and postoperative cardiac patients. Preliminary trials on patients recovering from cardiac surgery yielded an average correlation of r = 0.72 between CO at different Intra Aortic Balloon Pump (IABP) augmentation levels and SvO2 measured by the new venous oximeter. In intraoperative patients undergoing off-pump cardiac surgery, SvO2 recorded by the new technique responded to unplanned events such as a cardiac arrest. CONCLUSION: The new venous oximetry technique is a promising technique which responds to haemodynamic changes such as CO and with further development might offer an alternative means of monitoring SvO2 non-invasively.
NASA Astrophysics Data System (ADS)
Renard, Jean-Baptiste; Dulac, François; Vignelles, Damien; Jeannot, Matthieu; Verdier, Nicolas; Chazette, Patrick; Crenn, Vincent; Sciare, Jean; Totems, Julien; Durand, Pierre; Barret, Brice; Jambert, Corinne; Mallet, Marc; Menut, Laurent; Mailler, Sylvain; Basart, Sara; Baldasano, José Maria
2015-04-01
LOAC (Light Optical Aerosol Counter) is a new small optical particle counter/sizer of ~250 grams designed to fly under all kinds of balloons. The measurements are conducted at two scattering angles (12° and 60°), allowing the determination of the aerosol particle concentrations in 19 size classes within a diameter range of ~0.2-100 µm and some identification of the nature of particles dominating different size classes. Following laboratory calibration, the sensor particularly discriminates wet or liquid particles, mineral dust, soot carbon particles and salts. Comparisons with other in situ sensors at the surface and with remote sensing measurements on the vertical were performed to give confidence in measurements. The instrument has been operated at the surface, under all kinds of balloons up to more than 35 km in altitude, including tethered, sounding, open stratospheric and new boundary-layer pressurized drifting balloons (BLPB) from CNES, and was tested on board a small UAV. Operations encompass a variety of environments including the Arctic (Reykjavik, Island, and Kiruna, Sweden), Brazil (Sao Paolo), the western Mediterranean Basin, southwestern France, peri-urban (Ile de France) and urban areas (Paris and Vienna). Presented results are focused on the LOAC balloon-borne measurements performed in the western Mediterranean basin during MISTRALS/ChArMEx campaigns (Mediterranean Integrated Studies aT Regional And Local Scales/the Chemistry-Aerosol Mediterranean Experiment; http://www.mistrals-hjome.org; http://charmex.lsce.ipsl.fr), with a focus on African dust events. Two test flights with a first version of LOAC under sounding balloons were first successfully performed in late June 2012 near Marseille during an intense dust event. In 2013, 19 LOAC flights have been performed under meteorological balloons and 12 under low altitude drifting balloons, most of them from Minorca Island (Spain) in June and early July and others from Levant Island (south of France) in late July and early August . A number of the 2013 flights were coupled with ozone concentration measurements (see presentation of Gheusi et al. in the same session). LOAC balloons were especially, but not only, dedicated to study the various Saharan dust events that occurred during the campaign. In particular, a series of flights were conducted every 12 hours during the 15-19 June dust event. Forest fire smoke from North America was also sampled in late June over Minorca, as well as anthropogenic polluted layers in various occasions. LOAC data (available from ChArMEx database http://mistrals.sedoo.fr/ChArMEx) are interpreted with the help of coincident lidar, sun photometer remote sensing measurements available in Menorca, and satellite products and air mass trajectories. The sounding flights allow us to determine the vertical extent of the various aerosol layers, and to follow the particle size distribution and the concentration evolution along the vertical. The low altitude drifting balloons, which stayed roughly at constant altitude between 350 and 3330 m up to more than 25 h, allow us to study the time-evolution of the aerosol concentrations in the same air mass. Under both balloon types, LOAC has detected larges particles up to ~30 µm in diameter. The flights drifting within dust layers indicate that there is a relatively stable particle size distribution during transport over the sea, with no clear sedimentation loss of large particles. Aerosol simulations with the CHIMERE and NMMB/§BSC chemistry-transport models are compared to LOAC measurements. Acknowledgements: LOAC was developed with support of the French ANR. Balloon operations were performed by CNES and special acknowledgements are addressed to Gilles Dupouy, Françoise Douchin and collaborators for field operations. Alexis Doerenbacher from Météo-France and Claude Basdevant from Ecole Polytechnique are also acknowledged for their helpful contribution in providing balloon-related forecasts, quicklooks and data (http://www.lmd.polytechnique.fr/BAMED/index.html). The LOAC balloon campaigns were mainly funded by CNES, ADEME and CNRS/INSU, with support from CEA and Météo-France.
Development Specification for the Portable Life Support System (PLSS) Thermal Loop Pump
NASA Technical Reports Server (NTRS)
Anchondo, Ian; Campbell, Colin
2017-01-01
The AEMU Thermal Loop Pump Development Specification establishes the requirements for design, performance, and testing of the Water Pump as part of the Thermal System of the Advanced Portable Life Support System (PLSS). It is envisioned that the Thermal Loop Pump is a positive displacement pump that provides a repeatable volume of flow against a given range of back-pressures provided by the various applications. The intention is to operate the pump at a fixed speed for the given application. The primary system is made up of two identical and redundant pumps of which only one is in operation at given time. The Auxiliary Loop Pump is an identical pump design to the primary pumps but is operated at half the flow rate. Inlet positive pressure to the pumps is provided by the upstream Flexible Supply Assembly (FSA-431 and FSA-531) which are physically located inside the suit volume and pressurized by suit pressure. An integrated relief valve, placed in parallel to the pump's inlet and outlet protects the pump and loop from over-pressurization. An integrated course filter is placed upstream of the pump's inlet to provide filtration and prevent potential debris from damaging the pump.
Baylor Gyro Pump: a completely seal-less centrifugal pump aiming for long-term circulatory support.
Ohara, Y; Sakuma, I; Makinouchi, K; Damm, G; Glueck, J; Mizuguchi, K; Naito, K; Tasai, K; Orime, Y; Takatani, S
1993-07-01
A seal-less centrifugal pump aiming for long-term circulatory support has been developed. In this model, shaft seals that cause thrombus formation and blood leakage were eliminated. A brushless direct current motor was incorporated as a driving unit, and pivot bearings were used to support the impeller. With reference to its motor-driven system, this pump was named the M-Gyro Pump. The first model (M1) yielded an index of hemolysis of 0.005 g/100 L using bovine blood and demonstrated satisfactory performance as a right heart assist for 2 days (4 L/min, 60 mm Hg, 1,800 rpm). The second model (M2) has been developed for left heart assist by employing a stronger motor. The pump capacity was improved to 6 L/min against 240 mm Hg at 1,800 rpm, but significant heat generation was observed. By optimization of motor efficiency, the M2 model can be improved to meet the requirements of a pump for left heart assist.
Cassini Titan Flybys: The Next Year (April 2012 through April 2013)
NASA Astrophysics Data System (ADS)
Ray, T.; Burton, M.; Pitesky, J. E.; Steadman, K.; Roy, M.
2012-04-01
This poster describes the scientific, engineering, and operations planning for a Discovery / New Frontiers class Titan airplane mission, AVIATR (Aerial Vehicle for In-situ and Airborne Titan Reconnaissance). The mission would focus on Titan's surface and atmospheric diversity, using high-resolution imaging, near-infrared spectroscopy, a haze spectrometer, and atmospheric structure measurements. Previous mission studies have elected to use hot-air balloons to achieve similar science goals. These hot-air balloon concepts require the waste heat from inefficient thermocouple-based Radioisotope Thermoelectric Generators (RTGs) for buoyancy. New Advanced Stirling Radioisotope Generators (ASRGs) are much more efficient than RTGs both in terms of power produced per gram of plutonium-238 and the total watts-per-kilogram of the power unit itself. However, they are so efficient that they are much less effective for use in heating a hot-air balloon. Similarly, old-style RTGs produce insufficient specific power for heavier-than-air flight, but the use of 2 ASRGs can support a 120 kg airplane for a long-duration mission at Titan. The AVIATR airplane concept has several advantages in its science capabilities relative to a balloon, including the ability to target any site of interest, remaining on the dayside, stereo and repeat coverage, and easy altitude changes. It also possesses engineering advantages over a balloon like low total mass, a more straightforward deployment sequence, direct-to-Earth communications capability, and a more robust airframe.
Titan's atmosphere and surface in 2026: the AVIATR Titan Airplane Mission
NASA Astrophysics Data System (ADS)
McKay, Chris; Barnes, Jason W.; Lemke, Lawrence; Beyer, Ross A.; Radebaugh, Jani; Atkinson, David; Flasar, F. Michael
2010-04-01
This poster describes the scientific, engineering, and operations planning for a Discovery / New Frontiers class Titan airplane mission, AVIATR (Aerial Vehicle for In-situ and Airborne Titan Reconnaissance). The mission would focus on Titan's surface and atmospheric diversity, using high-resolution imaging, near-infrared spectroscopy, a haze spectrometer, and atmospheric structure measurements. Previous mission studies have elected to use hot-air balloons to achieve similar science goals. These hot-air balloon concepts require the waste heat from inefficient thermocouple-based Radioisotope Thermoelectric Generators (RTGs) for buoyancy. New Advanced Stirling Radioisotope Generators (ASRGs) are much more efficient than RTGs both in terms of power produced per gram of plutonium-238 and the total watts-per-kilogram of the power unit itself. However, they are so efficient that they are much less effective for use in heating a hot-air balloon. Similarly, old-style RTGs produce insufficient specific power for heavier-than-air flight, but the use of 2 ASRGs can support a 120 kg airplane for a long-duration mission at Titan. The AVIATR airplane concept has several advantages in its science capabilities relative to a balloon, including the ability to target any site of interest, remaining on the dayside, stereo and repeat coverage, and easy altitude changes. It also possesses engineering advantages over a balloon like low total mass, a more straightforward deployment sequence, direct-to-Earth communications capability, and a more robust airframe.
NASA Astrophysics Data System (ADS)
Guzik, T. G.
2017-12-01
On August 21, 2017 approximately 55 teams across the path of totality of the eclipse across America will use sounding balloon platforms to transmit, in real-time from an altitude of 90,000 feet, HD video of the moon's shadow as it crosses the U.S. from Oregon to South Carolina. This unprecedented activity was originally organized by the Montana Space Grant Consortium in order to 1) use the rare total eclipse event to captivate the imagination of students and encourage the development of new ballooning teams across the United States, 2) provide an inexpensive high bandwidth data telemetry system for real-time video streaming, and 3) establish the basic infrastructure at multiple institutions enabling advanced "new generation" student ballooning projects following the eclipse event. A ballooning leadership group consisting of Space Grant Consortia in Montana, Colorado, Louisiana, and Minnesota was established to support further development and testing of the systems, as well as to assist in training the ballooning teams. This presentation will describe the high bandwidth telemetry system used for the never before attempted live streaming of HD video from the edge of space, the results of this highly collaborative science campaign stretching from coast-to-coast, potential uses of the data telemetry system for other student science projects, and lessons learned that can be applied to the 2024 total solar eclipse.
Overview of the NASA Suborbital Program
NASA Astrophysics Data System (ADS)
Jones, W. Vernon
2014-08-01
The NASA Suborbital Program consists of Sounding Rocket and Balloon Projects managed, respectively, by the Heliophysics and Astrophysics Divisions of the Science Mission Directorate, which maintains “Program” Offices at the NASA Wallops Flight Facility. Suborbital missions have for several decades enabled investigations with significant results from relatively modest investments. Some have been competitive with orbital missions, while others have enabled orbital missions. NASA launches suborbital missions from sites established in the U.S. and around the world to meet investigators’ needs. A sea change in scientific ballooning occurred with the inauguration of 8 - 20 day flights around Antarctica in the early 1990’s. The U.S. National Science Foundation supports these circumpolar flights, which have been spectacularly successful with many investigations utilizing multiple flights of payloads that are recovered, refurbished, and reused to minimize life-cycle costs. The attainment of 25 - 32 day and 35 - 55 day flights in two and three circumnavigations, respectively, of the Antarctic continent has greatly increased expectations of scientific users. The 55-day Super-TIGER flight over Antarctica during the 2012-13 season broke the 42-day CREAM record during the 2004-05 season, as well as the 54-day super pressure balloon test flight in 2008-09. Qualification of super pressure flights to support 1000 kg science instruments for up to 100 days at 33 km have proceeded in parallel with plans to increase the altitude for less massive instruments requiring less atmospheric overburden. The nearly constant volume of super-pressure balloons allows stable altitude flights at non-polar latitudes. Long-duration flights in both polar and non-polar regions will confirm the important contributions that ballooning can make in traditional Astrophysics, Solar and Heliophysics, and Earth Science disciplines. With two comets approaching the sun in 2013-14, the Planetary Science community has shown increased interest in remote observations of comets, planets, and other objects in the Solar System.
NASA Astrophysics Data System (ADS)
Saad, Marissa Elizabeth
The United States must provide quality science, technology, engineering, and math (STEM) education in order to maintain a leading role in the global economy. Numerous initiatives have been established across the United States that promote and encourage STEM education within the middle school curriculum. Integrating active learning pedagogy into instructors' lesson plans will prepare the students to think critically - a necessary skill for the twenty first century. This study integrated a three-week long Near Space Balloon project into six eighth grade Earth Science classes from Valley Middle School in Grand Forks, North Dakota. It was hypothesized that after the students designed, constructed, launched, and analyzed their payload experiments, they would have an increased affinity for high school science and math classes. A pre- and post-survey was distributed to the students (n=124), before and after the project to analyze how effective this engineering and space mission was regarding high school STEM interests. The surveys were statistically analyzed, comparing means by the Student's t-Test, specifically the Welch-Satterthwaite test. Female students displayed a 57.1% increase in math and a 63.6% increase in science; male students displayed a 46.6% increase in science and 0% increase in math. Most Likert-scale survey questions experienced no statistically significant change, supporting the null hypothesis. The only survey question that supported the hypothesis was, "I Think Engineers Work Alone," which experienced a 0.24% decrease in student understanding. The results suggest that integrating a three-week long Near Space Balloon project into middle school curricula will not directly influence the students' excitement to pursue STEM subjects and careers. An extensive, yearlong ballooning mission is recommended so that it can be integrated with multiple core subjects. Using such an innovative pedagogy method as with this balloon launch will help students master the scientific process and experience real team collaboration, as they did in this successful mission.
Min, Yang Won; Lee, Jin Hee; Min, Byung-Hoon; Lee, Jun Haeng; Kim, Jae J; Rhee, Poong-Lyul
2014-01-01
Background/Aims The occurrence of gastroesophageal reflux disease (GERD) is known to be associated with lower post-treatment lower esophageal sphincter pressure in patients with achalasia. This study aimed to elucidate whether GERD after pneumatic balloon dilatation (PD) has a prognostic role and to investigate how the clinical course of GERD is. Methods A total of 79 consecutive patients who were first diagnosed with primary achalasia and underwent PD as an initial treatment were included in this retrospective study. Single PD was performed using a 3.0 cm balloon. The patients were divided into two groups: 1) who developed GERD after PD (GERD group) and 2) who did not develop GERD after PD (non-GERD group). GERD was defined as pathological acid exposure, reflux esophagitis or typical reflux symptoms. Results Twenty one patients (26.6%) developed GERD after PD during follow-up. There were no significant differences between the two groups in demographic or clinical factors including pre- and post-treatment manometric results. All patients in GERD group were well responsive to maintenance proton pump inhibitor therapy including on demand therapy or did not require maintenance. During a median follow-up of 17.8 months (interquartile range, 7.1–42.7 months), achalasia recurred in 15 patients (19.0%). However, the incidence of recurrence did not differ according to the occurrence of GERD after PD. Conclusions GERD often occurs after even a single PD for achalasia. However, GERD after PD is well responsive to PPI therapy. Our data suggest that GERD after PD during follow-up does not appear to have a prognostic role. PMID:24840373
Kohan, Luke C; Nagarajan, Vijaiganesh; Millard, Michael A; Loguidice, Michael J; Fauber, Nancy M; Keeley, Ellen C
2017-01-01
To assess if a change in our cardiology fellowship program impacted our ST elevation myocardial infarction (STEMI) program. Fellows covering the cardiac care unit were spending excessive hours in the hospital while on call, resulting in increased duty hours violations. A night float fellow system was started on July 1, 2012, allowing the cardiac care unit fellow to sign out to a night float fellow at 5:30 pm. The night float fellow remained in-house until the morning. We performed a retrospective study assessing symptom onset to arrival, arterial access to first device, and door-to-balloon (D2B) times, in consecutive STEMI patients presenting to our emergency department before and after initiation of the night float fellow system. From 2009 to 2013, 208 STEMI patients presented to our emergency department and underwent primary percutaneous coronary intervention. There was no difference in symptom onset to arrival (150±102 minutes vs 154±122 minutes, p =0.758), arterial access to first device (12±8 minutes vs 11±7 minutes, p =0.230), or D2B times (50±32 minutes vs 52±34 minutes, p =0.681) during regular working hours. However, there was a significant decrease in D2B times seen during off-hours (72±33 minutes vs 49±15 minutes, p =0.007). There was no difference in in-hospital mortality (11% vs 8%, p =0.484) or need for intra-aortic balloon pump placement (7% vs 8%, p =0.793). In academic medical centers, in-house cardiology fellow coverage during off-hours may expedite care of STEMI patients.
Wei, Xufeng; Sanchez, Pablo G; Liu, Yang; Li, Tieluo; Watkins, A Claire; Wu, Zhongjun J; Griffith, Bartley P
2015-01-01
Despite the significant contribution of the Fontan procedure to the therapy of complex congenital heart diseases, many patients progress to failure of their Fontan circulation. The use of ventricular assist devices to provide circulatory support to these patients remains challenging. In the current study, a continuous axial-flow pump was used to support a univentricular Fontan circulation. A modified Fontan circulation (atrio-pulmonary connection) was constructed in six Yorkshire piglets (8-14 kg). A Dacron conduit (12 mm) with two branches was constructed to serve as a complete atrio-pulmonary connection without the use of cardiopulmonary bypass. The Impella pump was inserted into the conduit through an additional Polytetrafluoroethylene (PTFE) graft in five animals. Hemodynamic data were collected for 6 hours under the supported Fontan circulation. The control animal died after initiating the Fontan circulation independent of resuscitation. Four pump supported animals remained hemodynamically stable for 6 hours with pump speeds between 18,000 rpm and 22,000 rpm (P1-P3). Oxygen saturation was maintained between 95% and 100%. Normal organ perfusion was illustrated by blood gas analysis and biochemical assays. A continuous axial-flow pump can be used for temporal circulatory support to the failing Fontan circulation as "bridge" to heart transplantation or recovery.
Development of a Compact, Efficient Cooling Pump for Space Suit Life Support Systems
NASA Technical Reports Server (NTRS)
van Boeyen, Roger; Reeh, Jonathan; Trevino, Luis
2009-01-01
A compact, low-power electrochemically-driven fluid cooling pump is currently being developed by Lynntech, Inc. With no electric motor and minimal lightweight components, the pump is significantly lighter than conventional rotodynamic and displacement pumps. Reliability and robustness is achieved with the absence of rotating or moving components (apart from the bellows). By employing sulfonated polystyrene-based proton exchange membranes, rather than conventional Nafion membranes, a significant reduction in the actuator power consumption was demonstrated. Lynntech also demonstrated that these membranes possess the necessary mechanical strength, durability, and temperature range for long life space operation. The preliminary design for a Phase II prototype pump compares very favorably to the fluid cooling pumps currently used in space suit primary life support systems (PLSSs). Characteristics of the electrochemically-driven pump are described and the benefits of the technology as a replacement for electric motor pumps in mechanically pumped single-phase fluid loops is discussed.
Coronary artery balloon angioplasty - slideshow
... Duplication for commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us Disclaimers Copyright ...
Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications
NASA Astrophysics Data System (ADS)
Hughes-Riley, Theodore; Six, Joseph S.; Lilburn, David M. L.; Stupic, Karl F.; Dorkes, Alan C.; Shaw, Dominick E.; Pavlovskaya, Galina E.; Meersmann, Thomas
2013-12-01
As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp 129Xe or hp 83Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp 129Xe handling, while 83Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The 83Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of 129Xe in corresponding mixtures. The experimental setup also facilitated 129Xe T1 relaxation measurements as a function of O2 concentration within excised lungs.
Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications☆
Hughes-Riley, Theodore; Six, Joseph S.; Lilburn, David M.L.; Stupic, Karl F.; Dorkes, Alan C.; Shaw, Dominick E.; Pavlovskaya, Galina E.; Meersmann, Thomas
2013-01-01
As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp 129Xe or hp 83Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp 129Xe handling, while 83Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The 83Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of 129Xe in corresponding mixtures. The experimental setup also facilitated 129Xe T1 relaxation measurements as a function of O2 concentration within excised lungs. PMID:24135800
Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications.
Hughes-Riley, Theodore; Six, Joseph S; Lilburn, David M L; Stupic, Karl F; Dorkes, Alan C; Shaw, Dominick E; Pavlovskaya, Galina E; Meersmann, Thomas
2013-12-01
As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp (129)Xe or hp (83)Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp (129)Xe handling, while (83)Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The (83)Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of (129)Xe in corresponding mixtures. The experimental setup also facilitated (129)Xe T1 relaxation measurements as a function of O2 concentration within excised lungs. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.
Biventricular support with the Jarvik 2000 axial flow pump: a feasibility study.
Radovancevic, Branislav; Gregoric, Igor D; Tamez, Daniel; Vrtovec, Bojan; Tuzun, Egemen; Chee, Hyun Keun; Moore, Sheila; Jarvik, Robert K; Frazier, O H
2003-01-01
Patients with congestive heart failure who are supported with a left ventricular assist device (LVAD) may experience right ventricular dysfunction or failure that requires support with a right ventricular assist device (RVAD). To determine the feasibility of using a clinically available axial flow ventricular assist device as an RVAD, we implanted Jarvik 2000 pumps in the left ventricle and right atrium of two Corriente crossbred calves (approximately 100 kg each) by way of a left thoracotomy and then analyzed the hemodynamic effects in the mechanically fibrillated heart at various LVAD and RVAD speeds. Right atrial implantation of the device required no modification of either the device or the surgical technique used for left ventricular implantation. Satisfactory biventricular support was achieved during fibrillation as evidenced by an increase in mean aortic pressure from 34 mm Hg with the pumps off to 78 mm Hg with the pumps generating a flow rate of 4.8 L/min. These results indicate that the Jarvik 2000 pump, which can provide chronic circulatory support and can be powered by external batteries, is a feasible option for right ventricular support after LVAD implantation and is capable of completely supporting the circulation in patients with global heart failure.
Quevedo, Henry C; Arain, Salman A; Ali, Gholam; Abi Rafeh, Nidal
2014-01-01
Revascularization of the peripheral arteries remains technically challenging. By decreasing the volume of the atherosclerotic plaque, debulking procedures may confer superior primary patency after revascularization. To assess the impact of atherectomy on primary patency rates at 12 months compared to balloon angioplasty and/or stent placement alone in patients with infrainguinal arterial disease. A database search for "directional," "orbital," "rotational," and "laser atherectomy" in peripheral arterial disease (PAD) was performed. Studies were screened according to the STROBE (Strengthening the Reporting of Observational studies in Epidemiology) critical appraisal tool and summarized by population, methodology, and outcomes (primary patency and major adverse events). Only two randomized studies were found. Most of the data were obtained from single-arm studies and registries. The primary patency with directional atherectomy approaches 60% at 12 months as a stand-alone technique, whereas orbital atherectomy in conjunction with balloon angioplasty and stenting achieved primary patency rates of 90%. Laser atherectomy is universally employed with balloon angioplasty and stenting for in-stent restenosis lesions with a primary patency rate of 64%. Although there are data for the safe use of rotational atherectomy, robust data to support its effectiveness are lacking. The combination of drug-coated balloons and atherectomy for the treatment of heavily calcified lesions in patients with critical limb ischemia is under evaluation. Despite the successful procedural outcomes reported in clinical registries, the available data do not support the use of atherectomy alone in PAD. Larger randomized controlled studies are warranted to define its role in contemporary endovascular practice.
Atmospheric and spectroscopic research in the far infrared
NASA Technical Reports Server (NTRS)
Park, Kwangjai; Radostitz, James V.
1992-01-01
The University of Oregon (UO) has been a major participant in the development of far infrared spectroscopic research of the stratosphere for the purpose of understanding the ozone layer processes. The UO has had a 15-year collaboration with the Italian group of B. Carli, and have participated in the 1978/79 Sub-millimeter Infrared Balloon Experiment (SIBEX), in the Balloon Intercomparison Campaign, (BIC), in the Infrared Balloon Experiment (IBEX), and in the recently concluded Far Infrared Experiment for UARS Correlative Measurements (FIREX). Both IBEX and FIREX programs were conducted in collaboration with NASA Langley, and were designed as validation flights in support of the Upper Atmosphere Research Satellite (UARS) Program. The technique of atmospheric far infrared spectroscopy offers two important advantages. First, many chemically important species can be measured simultaneously and co-spatially in the atmosphere. Second, far infrared atmospheric spectra can be obtained in thermal emission without reference to the sun's position, enabling full diurnal and global coverage. Recent improvements in instrumentation, field measurements, and molecular concentration retrieval techniques are now making the far infrared a mature measurement technology. This work to date has largely focused on balloon-based studies, but the future efforts will focus also on satellite-based experiments. A program of research in the following general areas was proposed: Laboratory Pressure broadening coefficient studies; specialized detector system assembly and testing; and consultation and assistance with instrument and field support. The proposal was approved and a three-year research grant titled 'Atmospheric and Spectroscopic Research in the Far Infrared' was awarded. A summary of technical accomplishments attained during the grant period are presented.
TLE Balloon experiment campaign carried out on 25 August 2006 in Japan
NASA Astrophysics Data System (ADS)
Takahashi, Y.; Chikada, S.; Yoshida, A.; Adachi, T.; Sakanoi, T.
2006-12-01
The balloon observation campaign for TLE and lightning study was carried out 25 August 2006 in Japan by Tohoku University, supported by JAXA. The balloon was successfully launched at 18:33 LT at Sanriku Balloon Center of JAXA located in the east coast of northern part of Japan (Iwate prefecture). Three types of scientific payloads were installed at the 1 m-cubic gondola, that is, 3-axis VLF electric filed antenna and receiver (VLFR), 4 video frame CCD cameras (CCDI) and 2-color photometer (PM). The video images were stored in 4 HD video recorders, which have 20GB memories respectively, at 30 frames/sec and VLFR and PM data were put into digital data recorder with 30 GB memory at sampling rate of 100 kHz. The balloon floated at the altitude of 13 km until about 20:30 LT, going eastward and went up to 26 km at a distance of 130 km from the coast. And it went back westward at the altitude of 26 km until midnight. The total observation period is about 5 hours. Most of the equipments worked properly except for one video recorder. Some thunderstorms existed within the direct FOV from the balloon in the range of 400-600 km and more than about 400 lightning flashes were recorded as video images. We confirmed that, at least, one sprite halo was captured by CCDI which occurred in the oceanic thunderstorm at a distance of about 500 km from balloon. This is the first TLE image obtained by a balloon-borne camera. Simultaneous measurements of VLF sferics and lightning/TLE images will clarify the role of intracloud (IC) currents in producing and/or modulating TLEs as well as cloud-to-ground discharges (CG). Especially the effect of horizontal components will be investigated in detail, which cannot be detected on the ground, to explain the unsolved properties of TLEs, such as long time delay of TLE from the timing of stroke and large horizontal displacement between CG and TLEs.
Circular pump support of blood circulation in the human body
NASA Astrophysics Data System (ADS)
Medvedev, A. E.; Fomin, V. M.; Prikhodko, Yu. M.; Cherniavskiy, A. M.; Fomichev, V. P.; Fomichev, A. V.; Chekhov, V. P.; Ruzmatov, T. M.
2016-10-01
The need of circulatory support systems in the treatment of chronic heart failure is increasing constantly, as 20% of patients in the waiting list die every year. Despite the great need for mechanical heart support systems, using of available systems is limited by the expensiveness. In addition, there is no one system that is 100% responsible to all medical and technical requirements, and would be completely safe for patient. Therefore, further research in the field of circu-latory support systems, considering health and technical requirements is relevant. One of the new directions in the study are disc pumps of viscous friction for liquid transporting, based on the Tesla pump principle. The operation principle of pumps based on the phenomenon of the boundary layer which is formed on the disk rotating in a fluid. There are experimental studies results of models with different variants of the rotor suspension, the various forms and the number of disks, forms the pump housing. However, none of the above samples was not brought to clinical trials. Furthermore, despite the promise of this model is still used today in some circulatory support systems are no similar type pump. Published data provide a basis for further development and testing of the pump model and allow to hope for leveling a number of significant shortcomings of modern left ventricular bypass systems.
Maximizing Lumen Gain With Directional Atherectomy.
Stanley, Gregory A; Winscott, John G
2016-08-01
To describe the use of a low-pressure balloon inflation (LPBI) technique to delineate intraluminal plaque and guide directional atherectomy in order to maximize lumen gain and achieve procedure success. The technique is illustrated in a 77-year-old man with claudication who underwent superficial femoral artery revascularization using a HawkOne directional atherectomy catheter. A standard angioplasty balloon was inflated to 1 to 2 atm during live fluoroscopy to create a 3-dimensional "lumenogram" of the target lesion. Directional atherectomy was performed only where plaque impinged on the balloon at a specific fluoroscopic orientation. The results of the LPBI technique were corroborated with multimodality diagnostic imaging, including digital subtraction angiography, intravascular ultrasound, and intra-arterial pressure measurements. With the LPBI technique, directional atherectomy can routinely achieve <10% residual stenosis, as illustrated in this case, thereby broadly supporting a no-stent approach to lower extremity endovascular revascularization. © The Author(s) 2016.
Rohof, Wout O; Bennink, Roelof J; de Jonge, Hugo; Boeckxstaens, Guy E
2014-10-01
Approximately 30% of patients with gastroesophageal reflux disease have symptoms resistant to treatment with proton pump inhibitors (PPIs). Several mechanisms such as esophageal hypersensitivity, increased mucosal permeability, and possibly the position of the gastric acid pocket might underlie a partial response to PPIs. To what extent these mechanisms interact and contribute to PPI-resistant symptoms, however, has not been investigated previously. In 18 gastroesophageal reflux disease patients (9 PPI responders and 9 PPI partial responders), esophageal sensitivity, mucosal permeability, and postprandial reflux parameters were determined during PPI use. Esophageal sensitivity for distension was measured by gradual balloon inflation at 5 and 15 cm above the lower esophageal sphincter. The mucosal permeability of 4 esophageal biopsy specimens per patient was determined in Ussing chambers by measuring the transepithelial electrical resistance and transmucosal flux of fluorescein. Postprandial reflux parameters were determined using concurrent high-resolution manometry/pH impedance after a standardized meal. In addition, the acid pocket was visualized using scintigraphy. No difference in the rate of postprandial acid reflux, in the pH of the acid pocket (PPI responders 3.7 ± 0.7 vs PPI partial responders 4.2 ± 0.4; P = .54), or in the position of the acid pocket was observed in PPI partial responders compared with PPI responders. In addition, the permeability of the esophageal mucosa was similar in both groups, as shown by a similar transepithelial electrical resistance and flux of fluorescein. PPI partial responders had more reflux episodes with a higher mean proximal extent, compared with PPI responders, and were more sensitive to balloon distension, both in the upper and lower esophagus. PPI-resistant symptoms most likely are explained by increased proximal reflux in a hypersensitive esophagus and less likely by increased mucosal permeability or the position of the acid pocket. Copyright © 2014 AGA Institute. Published by Elsevier Inc. All rights reserved.
Jensen, Jesper Khedri; Thayssen, Per; Antonsen, Lisbeth; Hougaard, Mikkel; Junker, Anders; Pedersen, Knud Erik; Jensen, Lisette Okkels
2015-03-01
Cardiogenic shock is a serious complication of a ST-segment elevation myocardial infarction (STEMI). We compared short- and long-term mortality among (1) STEMI patients with and without cardiogenic shock and (2) STEMI patients with cardiogenic shock with and without the use of an intra-aortic balloon pump (IABP). From January 1, 2002 to December 31, 2010, all patients presenting with STEMI and treated with primary percutaneous coronary intervention (PCI) were identified. The hazard ratio (HR) for death was estimated using a Cox regression model, controlling for potential confounding. The study cohort consisted of 4293 STEMI patients: 286 (6.7%) with and 4007 (93.3%) without cardiogenic shock. Compared with patients without cardiogenic shock, patients with cardiogenic shock were older, and more likely to have diabetes mellitus, multi-vessel disease, anterior myocardial infarction (MI) or bundle-branch block MI and a reduced creatinine clearance. Among patients with cardiogenic shock vs. without shock, 30-day cumulative mortality was 57.3% vs. 4.5% (p < 0.001), one-year cumulative mortality was 60.7% vs. 8.2% (p < 0.001) and five-year mortality was 65.0% vs. 18.9% (p < 0.001). STEMI with cardiogenic shock was associated with higher 30-day mortality (adjusted HR = 12.89 [95% CI: 9.72-16.66]), 1-year mortality (adjusted HR = 8.83 [95% CI: 7.06-11.05]) and five-year mortality (adjusted HR = 6.39 [95% CI: 5.22-7.80]). IABP was used in 71 (25%) patients with cardiogenic shock and was associated with improved 30-day outcome (adjusted HR = 0.48 [95% CI: 0.28-0.83]). Patients with STEMI and cardiogenic shock had substantial short- and long-term mortality that may be improved with IABP implantation. More studies on use of IABP in such patients are warranted.
Dziewierz, Artur; Siudak, Zbigniew; Rakowski, Tomasz; Kleczyński, Paweł; Zasada, Wojciech
2014-01-01
Introduction A large, randomised trial (IABP-SHOCK II) confirmed no benefit of intra-aortic balloon pump (IABP) on clinical outcomes of patients with ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock. However, the ‘sickest’ patients are often excluded from randomised clinical trials, so it is difficult to generalise expected outcomes from randomized clinical trials to the real life setting. Aim We sought to evaluate the impact of IABP on 1-year mortality of unselected patients with STEMI presenting in cardiogenic shock. Material and methods Data were gathered for 1,650 consecutive patients with STEMI transferred for primary angioplasty from hospital networks in 7 countries in Europe from November 2005 to January 2007 (the EUROTRANSFER registry population). Of them, 51 patients with cardiogenic shock on admission were identified and stratified based on the use of IABP. Outcome results were adjusted for age and sex, to control possible selection bias. Results At the discretion of the operators, IABP was applied in 30 patients (58.8%, IABP group). The remaining 21 patients were treated without IABP (no-IABP group). The use of IABP was more frequent among males, younger patients, and patients with STEMI of the anterior wall. There was no difference in 30-day mortality in patients with and without IABP (no-IABP vs. IABP: 38.1% vs. 33.3%; adjusted OR 1.79 (95% CI 0.43–7.52); p = 0.43). Similarly, IABP had no impact on 1-year mortality (42.9% vs. 33.3%; adjusted OR 1.27 (95% CI 0.32–5.09); p = 0.74). One-year mortality was comparable among patients who survived hospitalisation (14.3% vs. 13%; p = 0.64). Conclusions We observed no benefit of IABP on short – and long-term mortality of unselected patients with STEMI complicated by cardiogenic shock. PMID:25489303
Iqbal, M. Bilal; Robinson, Simon D.; Ding, Lillian; Fung, Anthony; Aymong, Eve; Chan, Albert W.; Hodge, Steven; Della Siega, Anthony; Nadra, Imad J.
2016-01-01
Background Cardiogenic shock complicating ST-elevation myocardial infarction (STEMI) is associated with significant morbidity and mortality. In the primary percutaneous coronary intervention (PPCI) era, randomized trials have not shown a survival benefit with intra-aortic balloon pump (IABP) therapy. This differs to observational data which show a detrimental effect, potentially reflecting bias and confounding. Without robust and valid risk adjustment, findings from non-randomized studies may remain biased. Methods We compared long-term mortality following IABP therapy in patients with cardiogenic shock undergoing PPCI during 2008–2013 from the British Columbia Cardiac Registry. We addressed measured and unmeasured confounding using propensity score and instrumental variable methods. Results A total of 12,105 patients with STEMI were treated with PPCI during the study period. Of these, 700 patients (5.8%) had cardiogenic shock. Of the patients with cardiogenic shock, 255 patients (36%) received IABP therapy. Multivariable analyses identified IABP therapy to be associated with increased mortality up to 3 years (HR = 1.67, 95% CI:1.20–2.67, p<0.001). This association was lost in propensity-matched analyses (HR = 1.23, 95% CI: 0.84–1.80, p = 0.288). When addressing measured and unmeasured confounders, instrumental variable analyses demonstrated that IABP therapy was not associated with mortality at 3 years (Δ = 16.7%, 95% CI: -12.7%, 46.1%, p = 0.281). Subgroup analyses demonstrated IABP was associated with increased mortality in non-diabetics; patients not undergoing multivessel intervention; patients without renal disease and patients not having received prior thrombolysis. Conclusions In this observational analysis of patients with STEMI and cardiogenic shock, when adjusting for confounding, IABP therapy had a neutral effect with no association with long-term mortality. These findings differ to previously reported observational studies, but are in keeping with randomized trial data. PMID:26870950
Fan, Zhong-Guo; Gao, Xiao-Fei; Chen, Li-Wen; Li, Xiao-Bo; Shao, Ming-Xue; Ji, Qian; Zhu, Hao; Ren, Yi-Zhi; Chen, Shao-Liang; Tian, Nai-Liang
2016-01-01
Background The effects of intra-aortic balloon pump (IABP) usage in patients with acute myocardial infarction remain controversial. This study sought to evaluate the outcomes of IABP usage in these patients. Methods Medline, EMBASE, and other internet sources were searched for relevant clinical trials. The primary efficacy endpoints (in-hospital, midterm, and long-term mortality) and secondary endpoints (reinfarction, recurrent ischemia, and new heart failure in the hospital) as well as safety endpoints (severe bleeding requiring blood transfusion and stroke in-hospital) were subsequently analyzed. Results Thirty-three clinical trials involving 18,889 patients were identified. The risk of long-term mortality in patients suffering from acute myocardial infarction was significantly decreased following IABP use (odds ratio [OR] 0.66, 95% confidence interval [CI]: 0.48–0.91, P=0.010). Both in-hospital and midterm mortality did not differ significantly between the IABP use group and no IABP use group (in-hospital: OR 0.87, 95% CI: 0.59–1.28, P=0.479; midterm: OR 1.12, 95% CI: 0.53–2.38, P=0.768). IABP insertion was not associated with the risk reduction of reinfarction, recurrent ischemia, or new heart failure. However, IABP use increased the risk of severe bleeding requiring blood transfusion (OR 2.05, 95% CI: 1.29–3.25, P=0.002) and stroke (OR 1.71, 95% CI: 1.04–2.82, P=0.035). In the thrombolytic therapy and cardiogenic shock subgroups, reduced mortality rates following IABP use were observed. Conclusion IABP insertion is associated with feasible benefits with respect to long-term survival rates in patients suffering from acute myocardial infarction, particularly those suffering from cardiogenic shock and receiving thrombolytic therapy, but at the cost of higher incidence of severe bleeding and stroke. PMID:27042021
Intra-aortic Balloon Pump-Dependent Patient Transports by Critical Care Paramedics.
MacDonald, Russell D; Allendes, Felipe
2016-01-01
Transport of intra-aortic balloon pump (IABP)-dependent patients between hospitals is increasingly common. The transports are typically time-sensitive and require personnel familiar with IABP operation and management of a potentially unstable patient. This study examined transports performed by specially trained critical care paramedics in a large air medical and land critical care transport service. This retrospective, descriptive review prospectively collected data for IABP-dependent patient transports in Ontario, Canada in a 10-year interval beginning September 2003. Call records and patient care reports were reviewed to capture demographic, patient care, adverse events, and transport-related data. Adverse events, including resuscitation medication, procedure, and patient instability, were independently reviewed by 2 investigators. There were 162 IABP-dependent patients transported. Seventy-one were performed by land critical care transport vehicles, 60 by helicopter, and 31 by fixed wing aircraft. The mean patient age was 63.7 ± 13.8 years; the majority (72.2%) were men. Fifty-nine patients (36.4%) were inotrope or vasopressor dependent, and 46 (28.4%) were intubated and mechanically ventilated. The most common indications for IABP insertion were acute myocardial infarction requiring prompt surgical intervention (n = 70), bridge to definitive care (n = 41), and cardiogenic shock (n = 37). The mean transport time was 92.7 ± 79.4 minutes. There were 48 adverse events in 35 patients, most commonly hypotension (systolic blood pressure < 90 mm Hg, n = 18) and tachyarrhythmia requiring therapy (n = 12). There were 3 IABP-related events and 3 cases in which the transport vehicle was inoperable resulting in a transport delay. One patient with cardiogenic shock died before departing the sending hospital. Paramedics managed all events without assistance from other health care personnel. Specially trained critical care flight paramedics can safely transport potentially unstable IABP-dependent patients to definitive cardiac surgical care. Copyright © 2016 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.
A new TDRSS Compatible Transceiver for Long Duration HIgh Altitude Scientific Balloon Missions
NASA Astrophysics Data System (ADS)
Stilwell, B.; Siemon, M.
High altitude scientific balloons have been used for many years to provide scientists with access to near space at a fraction of the cost of satellite based or sounding rocket experiments. In recent years, these balloons have been successfully used for long duration missions of up to several weeks. Longer missions with durations of up to 100 days (Ultra-Long) are on the drawing board. An enabling technology for the growth of the scientific balloon missions is the use of the NASA Tracking and Data Relay Satellite System (TDRSS) for telemetering the health, status, position and payload science data to mission operations personnel. The TDRSS system provides global coverage by relaying the data through geostationary relay satellites to a single ground station in White Sands New Mexico. Data passes from the White Sands station to the user via commercial telecommunications services including the Internet. A forward command link can also be established to the balloon for real- time command and control. Early TDRSS communications equipment used by the National Scientific Balloon Facility was either unreliable or too expensive. The equipment must be a le tob endure the rigors of space flight including radiation exposure, high temperature extremes and the shock of landing and recovery. Since a payload may occasionally be lost, the cost of the TDRSS communications gear is a limiting factor in the number of missions that can be supported. Under sponsorship of the NSBF, General Dynamics Decision Systems has developed a new TDRSS compatible transceiver that reduces the size, weight and cost to approximately one half that of the prior generation of hardware. This paper describes the long and ultra-long balloon missions and the role that TDRSS communications plays in mission success. The new transceiver design is described, along with its interfaces, performance characteristics, qualification and production status. The transceiver can also be used in other space, avionics or terrestrial applications.
Remote sensing from the desktop up, a students's personal stairway to space (Invited)
NASA Astrophysics Data System (ADS)
Church, W.
2013-12-01
Doing science with real-time quantitative experiments is becoming more and more affordable and accessible. Because lab equipment is more affordable and accessible, many universities are using lab class models wherein students conduct their experiments in informal settings such as the dorm, outside, or other places throughout the campus. Students are doing real-time measurements homework outside of class. By liberating experiments from facilities, the hope is to give students more experimental science opportunities. The challenge is support. In lab settings, instructors and peers can help students if they have trouble with the steps of assembling their experimental set-up, configuring the data acquisition software, conducting the real-time measurement and doing the analysis. Students working on their own in a dorm do not benefit from this support. Furthermore, when students are given the open ended experimental task of designing their own measurement system, they may need more guidance. In this poster presentation, I will articulate a triangle model to support students through the task of finding the necessary resources to design and build a mission to space. In the triangle model, students have access to base layer concept and skill resources to help them build their experiment. They then have access to middle layer mini-experiments to help them configure and test their experimental set-up. Finally, they have a motivating real-time experiment. As an example of this type of resource used in practice, I will have a balloon science remote sensing project as a stand-in for a balloon mission to 100,000 feet. I will use an Arduino based DAQ system and XBee modules for wireless data transmission to a LabVIEW front-panel. I will attach the DAQ to a tethered balloon to conduct a real-time microclimate experiment in the Moscone Center. Expanded microclimate studies can be the capstone project or can be a stepping-stone to space wherein students prepare a sensor package for a weather balloon launch to 100,000 feet.
The Montgolfier Brothers and the Invention of Aviation
NASA Astrophysics Data System (ADS)
Moore, Charles B.
The first hot air balloon ascension over Paris in September 1783 has been described so many times that it and its passengers—the sheep, the rooster, and the duck—have joined Benjamin Franklin and his kite in the folklore of our culture. Not so well known is the earlier history of ballooning; that the brothers Montgolfier had demonstrated their hot air balloons repeatedly for several months prior to the ascent over Paris; or that the physicist Charles, urged onward and financed by an enthusiast, Barthélemy Faujas de Saint-Fond, launched successfully the first fabric balloon filled with hydrogen over Paris more than 3 weeks prior to the memorable ascent of the sheep, and rooster, and the duck.For all of its well-documented detail, the book is readable and enjoyable. It is a well-written but complex book in which Professor Gillispie develops a number of subjects to recreate the era in perspective. The origins and the disposition of the Montgolfiers, the industry of the period, the idea of capturing heated air are all reported in detail. The attempts to obtain government funding and the promotional activities in Paris were forerunners of the modern techniques for obtaining support of research activities.
In Vitro Determination of Drug Transfer from Drug-Coated Balloons
Seidlitz, Anne; Kotzan, Nadine; Nagel, Stefan; Reske, Thomas; Grabow, Niels; Harder, Claus; Petersen, Svea; Sternberg, Katrin; Weitschies, Werner
2013-01-01
Drug-coated balloons are medical devices designed to locally deliver drug to diseased segments of the vessel wall. For these dosage forms, drug transfer to the vessel wall needs to be examined in detail, since drug released into the blood is cleared from the site. In order to examine drug transfer, a new in vitro setup was developed combining the estimation of drug loss during advancement to the site of application in a model coronary artery pathway with a hydrogel compartment representing, as a very simplified model, the vessel wall. The transfer of fluorescent model substances as well as the drug paclitaxel from coated balloons to the simulated vessel wall was evaluated using this method. The model was suitable to quantify the fractions transferred to the hydrogel and also to qualitatively assess distribution patterns in the hydrogel film. In the case of fluorescein sodium, rhodamin b and paclitaxel, vast amounts of the coated substance were lost during the simulated passage and only very small fractions of about 1% of the total load were transferred to the gel. This must be attributed to good water solubility of the fluorescent substances and the mechanical instability of the paclitaxel coating. Transfer of the hydrophobic model substance triamterene was however nearly unaffected by the preliminary tracking procedure with transferred fractions ranging from 8% to 14%. Analysis of model substance distribution yielded inhomogeneous distributions indicating that the coating was not evenly distributed on the balloon surface and that a great fraction of the coating liquid did not penetrate the folds of the balloon. This finding is contradictory to the generally accepted assumption of a drug depot inside the folds and emphasizes the necessity to thoroughly characterize in vitro performance of drug-coated balloons to support the very promising clinical data. PMID:24391863
Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik; Holmstrup, Palle; Helqvist, Steffen; Tolker-Nielsen, Tim; Givskov, Michael; Hansen, Peter Riis
2015-01-01
Periodontitis is a chronic, bacterially-induced inflammatory disease of the tooth-supporting tissues, which may result in transient bacteremia and a systemic inflammatory response. Periodontitis is associated with coronary artery disease independently of established cardiovascular risk factors, and translocation of bacteria from the oral cavity to the coronary arteries may play a role in the development of coronary artery disease. Very few studies have used angioplasty balloons for in vivo sampling from diseased coronary arteries, and with varying results. Therefore, the aim of this study was to assess if bacterial DNA from primarily oral bacteria could be detected on coronary angioplasty balloons by use of an optimized sampling process combined with an internally validated sensitive polymerase chain reaction (PCR) assay. Coronary angioplasty balloons and control samples from a total of 45 unselected patients with stable angina, unstable angina/non-ST elevation myocardial infarction, and ST-elevation myocardial infarction (n = 15 in each group) were collected and analyzed using a PCR assay with high sensitivity and specificity for 16S rRNA genes of the oral microbiome. Despite elimination of extraction and purification steps, and demonstration of sensitivity levels of 25–125 colony forming units (CFU), we did not detect bacterial DNA from any of the coronary angioplasty balloons. A subsequent questionnaire indicated that the prevalence of periodontitis in the study cohort was at least 39.5%. Although coronary angioplasty balloons are unlikely to be useful for detection of bacteria with current PCR techniques in unselected patients with coronary artery disease, more studies are warranted to determine the extent to which bacteria contribute to atherosclerosis and its clinical manifestations and whether the presence of bacteria in the arteries is a transient phenomenon. PMID:26695491
Electrodynamics of the stratosphere using 5000 m3 superpressure balloons
NASA Astrophysics Data System (ADS)
Holzworth, R. H.
Recently the U. S. National Science Foundation and NASA have begun support of a long duration balloon-borne experiment to study electrical properties of the upper atmosphere. This research project titled EMA (Electrodynamics of the Middle Atmopshere) involves the design of a microprocessor controlled payload and the launch of up to eight small superpressure balloons during 1982 through early 1984. The primary payload instrument will measure the vector electric field from DC to 10 kHz and the payloads will include instruments to measure local ionization, electrical conductivity, magnetic field, pressure and temperature fluctuations and to record optical lightning. Measurement of these parameters in the stratosphere from a few balloons simultaneously for periods extending over a few solar rotations will enable us to study (1) electrical coupling between the atmosphere and magnetosphere, (2) global current systems, (3) global response to solar flares and magnetospheric storms and many other outstanding problems. In order to obtain long duration flights, it is necessary to fly in the southern hemisphere where the balloons are expected to circle the globe dozens of times in their lifetimes. Thus the balloons will be out of direct communication with any one ground station most of the time so the telemetry will be relayed via satellite. This severely limits the data rates resulting in the need for on-board data processing. This is accomplished through the use of dual microcomputers for data analysis and for telemetry formatting. This talk will concentrate on a description of our payload design as driven by the scientific requirements. Examples of the types of electric field signatures we expect to be able to distinguish will also be presented.
Reconnection and interchange instability in the near magnetotail
Birn, Joachim; Liu, Yi -Hsin; Daughton, William; ...
2015-07-16
This paper provides insights into the possible coupling between reconnection and interchange/ballooning in the magnetotail related to substorms and flow bursts. The results presented are largely based on recent simulations of magnetotail dynamics, exploring onset and progression of reconnection. 2.5-dimensional particle-in-cell (PIC) simulations with different tail deformation demonstrate a clear boundary between stable and unstable cases depending on the amount of deformation, explored up to the real proton/electron mass ratio. The evolution prior to onset, as well as the evolution of stable cases, are governed by the conservation of integral flux tube entropy S as imposed in ideal MHD, maintainingmore » a monotonic increase with distance downtail. This suggests that ballooning instability in the tail should not be expected prior to the onset of tearing and reconnection. 3-D MHD simulations confirm this conclusion, showing no indication of ballooning prior to reconnection, if the initial state is ballooning stable. The simulation also shows that, after imposing resistivity necessary to initiate reconnection, the reconnection rate and energy release initially remain slow. However, when S becomes reduced from plasmoid ejection and lobe reconnection, forming a negative slope in S as a function of distance from Earth, the reconnection rate and energy release increase drastically. The latter condition has been shown to be necessary for ballooning/interchange instability, and the cross-tail structures that develop subsequently in the MHD simulation are consistent with such modes. The simulations support a concept in which tail activity is initiated by tearing instability but significantly enhanced by the interaction with ballooning/interchange enabled by plasmoid loss and lobe reconnection.« less
Control of Postpartum Hemorrhage Using Vacuum-Induced Uterine Tamponade.
Purwosunu, Yuditiya; Sarkoen, Widyastuti; Arulkumaran, Sabaratnam; Segnitz, Jan
2016-07-01
Postpartum hemorrhage is the leading cause of maternal mortality worldwide. Vacuum-induced uterine tamponade is a possible alternative approach to balloon tamponade systems for the treatment of postpartum hemorrhage resulting from atony. In a prospective proof-of-concept investigation of 10 women with vaginal deliveries in a hospital setting who failed first-line therapies for postpartum hemorrhage, tamponade was used. Vacuum-induced uterine tamponade was created through a device inserted transvaginally into the uterine cavity. An occlusion balloon built into the device shaft was inflated at the level of the external cervical os to create a uterine seal. Negative pressure was created by attaching a self-contained, mobile, electrically powered, pressure-regulated vacuum pump with a sterile graduated canister. In all 10 cases, the suction created an immediate seal at the cervical os, 50-250 mL of residual blood was evacuated from the uterine cavity, the uterus collapsed and regained tone within minutes, and hemorrhaging was controlled. The device remained in place for a minimum of 1 hour and up to 6.5 hours in one case while vaginal and perineal lacerations were easily repaired. This preliminary investigation suggests that a device designed to create vacuum-induced uterine tamponade may be a reasonable alternative to other devices used to treat atonic postpartum hemorrhage.
Early history of high-altitude physiology.
West, John B
2016-02-01
High-altitude physiology can be said to have begun in 1644 when Torricelli described the first mercury barometer and wrote the immortal words "We live submerged at the bottom of an ocean of the element air." Interestingly, the notion of atmospheric pressure had eluded his teacher, the great Galileo. Blaise Pascal was responsible for describing the fall in pressure with increasing altitude, and Otto von Guericke gave a dramatic demonstration of the enormous force that could be developed by atmospheric pressure. Robert Boyle learned of Guericke's experiment and, with Robert Hooke, constructed the first air pump that allowed small animals to be exposed to a low pressure. Hooke also constructed a small low-pressure chamber and exposed himself to a simulated altitude of about 2400 meters. With the advent of ballooning, humans were rapidly exposed to very low pressures, sometimes with tragic results. For example, the French balloon, Zénith, rose to over 8000 m, and two of the three aeronauts succumbed to the hypoxia. Paul Bert was the first person to clearly state that the deleterious effects of high altitude were caused by the low partial pressure of oxygen (PO2), and later research was accelerated by high-altitude stations and expeditions to high altitude. © 2015 New York Academy of Sciences.
Medical devices of the head, neck, and spine.
Hunter, Tim B; Yoshino, Mark T; Dzioba, Robert B; Light, Rick A; Berger, William G
2004-01-01
There are many medical devices used for head, neck, and spinal diseases and injuries, and new devices are constantly being introduced. Many of the newest devices are variations on a previous theme. Knowing the specific name of a device is not important. It is important to recognize the presence of a device and to have an understanding of its function as well as to be able to recognize the complications associated with its use. The article discusses the most common and important devices of the head, neck, and spine, including cerebrospinal fluid shunts and the Codman Hakim programmable valve; subdural drainage catheters, subdural electrodes, intracranial electrodes, deep brain stimulators, and cerebellar electrodes; coils, balloons, adhesives, particles, and aneurysm clips; radiation therapy catheters, intracranial balloons for drug installation, and carmustine wafers; hearing aids, cochlear implants, and ossicular reconstruction prostheses; orbital prostheses, intraocular silicone oil, and lacrimal duct stents; anterior and posterior cervical plates, posterior cervical spine wiring, odontoid fracture fixation devices, cervical collars and halo vests; thoracic and lumbar spine implants, anterior and posterior instrumentation for the thoracic and lumbar spine, vertebroplasty, and artificial disks; spinal column stimulators, bone stimulators, intrathecal drug delivery pumps, and sacral stimulators; dental and facial implant devices; gastric and tracheal tubes; vagus nerve stimulators; lumboperitoneal shunts; and temperature- and oxygen-sensing probes. Copyright RSNA, 2004
Simulation of the Beating Heart Based on Physically Modeling aDeformable Balloon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rohmer, Damien; Sitek, Arkadiusz; Gullberg, Grant T.
2006-07-18
The motion of the beating heart is complex and createsartifacts in SPECT and x-ray CT images. Phantoms such as the JaszczakDynamic Cardiac Phantom are used to simulate cardiac motion forevaluationof acquisition and data processing protocols used for cardiacimaging. Two concentric elastic membranes filled with water are connectedto tubing and pump apparatus for creating fluid flow in and out of theinner volume to simulate motion of the heart. In the present report, themovement of two concentric balloons is solved numerically in order tocreate a computer simulation of the motion of the moving membranes in theJaszczak Dynamic Cardiac Phantom. A system ofmore » differential equations,based on the physical properties, determine the motion. Two methods aretested for solving the system of differential equations. The results ofboth methods are similar providing a final shape that does not convergeto a trivial circular profile. Finally,a tomographic imaging simulationis performed by acquiring static projections of the moving shape andreconstructing the result to observe motion artifacts. Two cases aretaken into account: in one case each projection angle is sampled for ashort time interval and the other case is sampled for a longer timeinterval. The longer sampling acquisition shows a clear improvement indecreasing the tomographic streaking artifacts.« less
... using x-rays and injected contrast dye to evaluate blood vessels) Angioplasty (using a small balloon to ... ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow ...
Choroidal microcirculation in patients with rotary cardiac assist device.
Polska, Elzbieta; Schima, Heinrich; Wieselthaler, Georg; Schmetterer, Leopold
2007-06-01
In recent years, fully implanted rotary blood pumps have been used for long-term cardiac assist in patients with end-stage heart failure. With these pumps, the pulsatility of arterial blood flow and arterial pressure pulse is considerably reduced. Effects on end-organ perfusion, particularly microcirculation, have been assessed. The ocular choroid offers a unique opportunity to study the pulsatile component of blood flow by measurement of fundus pulsation amplitude (FPA) as well as the microcirculation by laser Doppler flowmetry. Both techniques were applied in three male patients with rotary pumps (MicroMed DeBakey VAD), in whom pump velocity was adjusted to four levels of flow between individual minimal need and maximal support. In addition, blood flow velocities in the ophthalmic artery (peak, end-diastolic and mean flow velocity--PSV, EDV and MFV, respectively) were measured using color Doppler imaging. Systolic blood pressure increased by 6 to 22 mm Hg with increasing support. At maximal support FPA was reduced by -60% to -52% as compared with minimal pump support. Blood flow in the choroidal microvasculature, however, did not show relevant changes. A reduction in PSV (-31%, range -47% to -21%) and a pronounced rise in EDV (+93%, range +28% to +147%) was observed, whereas MFV was independent of pump flow. Our data indicate that mean choroidal blood flow is maintained when pump support is varied within therapeutic values, whereas the ratio of pulsatile to non-pulsatile choroidal flow changes. This study shows that, in patients with ventricular assist devices, a normal perfusion rate in the ocular microcirculation is maintained over a wide range of support conditions.
NASA Technical Reports Server (NTRS)
Rosen, James M.; Hofmann, D. J.; Carpenter, J. R.; Harder, J. W.; Oltsmans, S. J.
1988-01-01
Balloon-borne frost point measurements were performed over Antarctica during September-October 1987 as part of the NOZE II effort at McMurdo. The results show water mixing ratios on the order of 2 ppmv in the 20 km region, suggesting that models of the springtime Antarctic stratosphere should be based on approximately 2 ppmv water vapor. Evidence indicating that some PSCs form at temperatures higher than the frost point in the 15 to 20 km region is discussed. This supports the binary HNO3-H2O theory of PSC composition.
Kolyva, Christina; Pepper, John R; Khir, Ashraf W
2016-08-01
The major hemodynamic benefits of intra-aortic balloon pump (IABP) counterpulsation are augmentation in diastolic aortic pressure (Paug ) during inflation, and decrease in end-diastolic aortic pressure (ΔedP) during deflation. When the patient is nursed in the semirecumbent position these benefits are diminished. Attempts to change the shape of the IAB in order to limit or prevent this deterioration have been scarce. The aim of the present study was to investigate the hemodynamic performance of six new IAB shapes, and compare it to that of a traditional cylindrical IAB. A mock circulation system, featuring an artificial left ventricle and an aortic model with 11 branches and physiological resistance and compliance, was used to test one cylindrical and six newly shaped IABs at angles 0, 10, 20, 30, and 40°. Pressure was measured continuously at the aortic root during 1:1 and 1:4 IABP support. Shape 2 was found to consistently achieve, in terms of absolute magnitude, larger ΔedP at angles than the cylindrical IAB. Although ΔedP was gradually diminished with angle, it did so to a lesser degree than the cylindrical IAB; this diminishment was only 53% (with frequency 1:1) and 40% (with frequency 1:4) of that of the cylindrical IAB, when angle increased from 0 to 40°. During inflation Shape 1 displayed a more stable behavior with increasing angle compared to the cylindrical IAB; with an increase in angle from 0 to 40°, diastolic aortic pressure augmentation dropped only by 45% (with frequency 1:1) and by 33% (with frequency 1:4) of the drop reached with the cylindrical IAB. After compensating for differences in nominal IAB volume, Shape 1 generally achieved higher Paug over most angles. Newly shaped IABs could allow for IABP therapy to become more efficient for patients nursed at the semirecumbent position. The findings promote the idea of personalized rather than generalized patient therapy for the achievement of higher IABP therapeutic efficiency, with a choice of IAB shape that prioritizes the recovery of those hemodynamic indices that are more in need of support in the unassisted circulation. © 2016 The Authors Artificial Organs published by Wiley Periodicals, Inc. on behalf of International Center for Artificial Organ and Transplantation (ICAOT).
Kolyva, Christina; Pepper, John R.
2016-01-01
Abstract The major hemodynamic benefits of intra‐aortic balloon pump (IABP) counterpulsation are augmentation in diastolic aortic pressure (P aug) during inflation, and decrease in end‐diastolic aortic pressure (ΔedP) during deflation. When the patient is nursed in the semirecumbent position these benefits are diminished. Attempts to change the shape of the IAB in order to limit or prevent this deterioration have been scarce. The aim of the present study was to investigate the hemodynamic performance of six new IAB shapes, and compare it to that of a traditional cylindrical IAB. A mock circulation system, featuring an artificial left ventricle and an aortic model with 11 branches and physiological resistance and compliance, was used to test one cylindrical and six newly shaped IABs at angles 0, 10, 20, 30, and 40°. Pressure was measured continuously at the aortic root during 1:1 and 1:4 IABP support. Shape 2 was found to consistently achieve, in terms of absolute magnitude, larger ΔedP at angles than the cylindrical IAB. Although ΔedP was gradually diminished with angle, it did so to a lesser degree than the cylindrical IAB; this diminishment was only 53% (with frequency 1:1) and 40% (with frequency 1:4) of that of the cylindrical IAB, when angle increased from 0 to 40°. During inflation Shape 1 displayed a more stable behavior with increasing angle compared to the cylindrical IAB; with an increase in angle from 0 to 40°, diastolic aortic pressure augmentation dropped only by 45% (with frequency 1:1) and by 33% (with frequency 1:4) of the drop reached with the cylindrical IAB. After compensating for differences in nominal IAB volume, Shape 1 generally achieved higher P aug over most angles. Newly shaped IABs could allow for IABP therapy to become more efficient for patients nursed at the semirecumbent position. The findings promote the idea of personalized rather than generalized patient therapy for the achievement of higher IABP therapeutic efficiency, with a choice of IAB shape that prioritizes the recovery of those hemodynamic indices that are more in need of support in the unassisted circulation. PMID:27530674
GPS-aided gravimetry at 30 km altitude from a balloon-borne platform
NASA Technical Reports Server (NTRS)
Lazarewicz, Andrew R.; Evans, Alan G.
1989-01-01
A balloon-borne experiment, flown at 30 km altitude over New Mexico, was used to test dynamic differential Global Positioning System (GPS) tracking in support of gravimetry at high-altitudes. The experiment package contained a gravimeter (Vibrating String Accelerometer), a full complement of inertial instruments, a TI-4100 GPS receiver and a radar transponder. The flight was supported by two GPS receivers on the ground near the flight path. From the 8 hour flight, about a forty minute period was selected for analysis. Differential GPS phase measurements were used to estimate changes in position over the sample time interval, or average velocity. In addition to average velocity, differential positions and numerical averages of acceleration were obtained in three components. Gravitational acceleration was estimated by correcting for accelerations due to translational motion, ignoring all rotational effects.
Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J; Jacob, Augustinus L; Bilecen, Deniz
2009-04-01
Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft tip, and a hydrophilic coating was used. Paramagnetic markings were coated on the wire and nonbraided catheters for passive visualization. Bending stiffness of the guidewire was compared with available hydrophilic guidewires (Terumo Glidewire Stiff and Standard). A human aortic silicon phantom and 2 pigs were used. The study was animal care and use approved by the committee. Under MR-guidance, renal arteries were catheterized, balloon angioplasty was performed, and balloon expandable renal artery stents were deployed in vivo. Post mortem autopsy was performed. Guidewire visibility, pushability, steerability, and device-support capabilities of the marked guidewire were qualitatively assessed. Procedure times were recorded. Bending stiffness of the new PEEK-based wire was comparable with Standard Glidewire. In vitro and in vivo guidewire guidance, catheter configuration, renal artery catheterization, and balloon angioplasty were successful. In pigs, stent deployments were successful in both renal arteries. Autopsy revealed acceptable stent positioning. Guidewire visibility through applied markers was acceptable. Steerability, pushability, and device support were good in vitro and in vivo. The PEEK-based guide allows percutaneous MR-guided renal artery angioplasty and stenting with sufficient visibility, good steerability, pushability, and device support.
PIPER Continuous Adiabatic Demagnetization Refrigerator
NASA Technical Reports Server (NTRS)
Kimball, Mark O.; Shirron, Peter J.; Canavan, Edgar R.; James, Bryan L.; Sampson, Michael A.; Letmate, Richard V.
2017-01-01
We report upon the development and testing of a 4-stage adiabatic demagnetization refrigerator (ADR) capable of continuous cooling at 0.100 Kelvin. This cooler is being built to cool the detector array aboard NASA's Primordial Inflation Polarization Explorer (PIPER) observatory. The goal of this balloon mission is to measure the primordial gravitational waves that should exist if the theory of cosmological inflation is correct. At altitude, the ADR will hold the array of transition-edge sensors at 100 mK continuously while periodically rejecting heat to a 1.2 K pumped helium bath. During testing on ground, the array is held at the same temperature but heat is rejected to a 4.2 K helium bath indicating the flexibility in this coolers design.
Broken heart syndrome triggered by an obstructive goiter not associated with thyrotoxicosis.
Hatzakorzian, Roupen; Bui, Helen; Schricker, Thomas; Backman, Steven B
2013-08-01
Takotsubo cardiomyopathy (TC) is described as transient ventricular dysfunction following emotional or physical trauma. A few reports have described patients with TC in association with various circumstances of thyrotoxicosis. We report an unusual case of TC in a patient with a large retrosternal goiter and normal thyroid function. We speculate that TC was triggered by compromise of tracheal flow induced by the goiter. A 68-yr-old woman without primary heart disease presented with cardiorespiratory collapse requiring ventilatory and cardiovascular support, including placement of an intra-aortic balloon pump. She was diagnosed with a severe form of TC based on characteristic echocardiography findings and clinical course. Within less than a week, her myocardial function completely normalized. The patient was later found to have a large retrosternal goiter compressing her trachea, though her thyroid function was normal. A total thyroidectomy was eventually performed, and she made a full recovery. Subsequently, the patient was found to have a positive JAK2 mutation for a myeloproliferative disorder. Takotsubo cardiomyopathy may be regarded as the final common pathway of cardiac dysfunction triggered by various stress conditions, in this case, a large retrosternal goiter not associated with thyrotoxicosis and likely exacerbated by severe leukocytosis related to a myeloproliferative disorder.
Breast milk pumping beliefs, supports, and barriers on a university campus.
Dinour, Lauren M; Pope, Gina A; Bai, Yeon K
2015-02-01
Compared to nonemployed mothers, employed mothers are more likely to terminate breastfeeding sooner than recommended, due in part to a lack of workplace support. The purpose of this study is to compare the beliefs of employees and students affiliated with a university regarding pumping breast milk on campus. This qualitative study used semistructured interviews grounded in the theory of planned behavior, focused on behavioral, normative, and control beliefs regarding pumping on campus. Responses were independently coded and categorized based on common themes. Response frequencies were calculated and compared between students, staff, and faculty. Thirty-two women (11 students, 8 staff, 13 faculty) participated in the interview. Overall, participants most frequently reported that maintaining milk supply/extending breastfeeding duration was an advantage to pumping on campus, and time/scheduling issues a disadvantage. The most commonly perceived supporters were peers, whereas those unaware, uninformed, and/or disapproving of breastfeeding were most commonly perceived as opponents to pumping on campus. Reporting within each category differed between students, staff, and faculty. It is notable that students most frequently identified the lack of available pumping space as a barrier, whereas faculty often reported that space availability made pumping on campus easier for them. In addition, both staff and faculty frequently stated that scheduling and time constraints were a pumping barrier. An inequality of current lactation support practice may exist at colleges and universities. It is necessary to extend this protection to all members of a workplace, regardless of their role. © The Author(s) 2014.
Overview of the Radiation Dosimetry Experiment (RaD-X) flight mission
NASA Astrophysics Data System (ADS)
Mertens, Christopher J.
2016-11-01
The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission addresses the need to reduce the uncertainty in predicting human exposure to cosmic radiation in the aircraft environment. Measurements were taken that characterize the dosimetric properties of cosmic ray primaries, the ultimate source of aviation radiation exposure, and the cosmic ray secondary radiations that are produced and transported to aviation altitudes. In addition, radiation detectors were flown to assess their potential application to long-term, continuous monitoring of the aircraft radiation environment. RaD-X was successfully launched from Fort Sumner, New Mexico (34.5°N, 104.2°W), on 25 September 2015. Over 18 h of science data were obtained from a total of four different type dosimeters at altitudes above 20 km. The RaD-X flight mission was supported by laboratory radiation exposure testing of the balloon flight dosimeters and also by coordinated radiation measurements taken on ER-2 and commercial aircraft. This paper provides the science background and motivation for the RaD-X flight mission, a brief description of the balloon flight profile and the supporting aircraft flights, and a summary of the articles included in the RaD-X special collection and their contributions to the science goals of the RaD-X mission.
NASA Technical Reports Server (NTRS)
Houtas, Franzeska F.; Teets, Edward H.
2010-01-01
A comparison study by the National Aeronautics and Space Administration Dryden Flight Research Center (Edwards, California) and the Naval Post Graduate School Center for Interdisciplinary Remotely-Piloted Aircraft Studies (Marina, California) was conducted to show the advantages of an airborne wind profiling light detection and ranging (lidar) system in reducing drift uncertainty along a reentry vehicle descent trajectory. This effort was in support of the once planned Orion Crew Exploration Vehicle ground landing. A Twin Otter Doppler Wind Lidar was flown on multiple flights along the approximate ground track of each ascending weather balloon launched from the Marina Municipal Airport (Marina, California). The airborne lidar used was a 5-mJ, 2-micron infrared laser with a 10-cm telescope and a two-axis scanner. Each lidar wind profile contains data for an altitude range between the surface and flight altitude of 2.7 km, processed on board every 20 s. In comparison, a typical weather balloon would traverse that same altitude range with a similar data set available in approximately 15 to 20 min. These tests were conducted on November 15 and 16, 2007. Results show a best-case absolute difference of 0.18 m/s (0.35 knots) in speed and 1 degree in direct
Overview of the Radiation Dosimetry Experiment (RaD-X) Flight Mission
NASA Technical Reports Server (NTRS)
Mertens, Christopher J.
2016-01-01
The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission addresses the need to reduce the uncertainty in predicting human exposure to cosmic radiation in the aircraft environment. Measurements were taken that characterize the dosimetric properties of cosmic ray primaries, the ultimate source of aviation radiation exposure, and the cosmic ray secondary radiations that are produced and transported to aviation altitudes. In addition, radiation detectors were flown to assess their potential application to long-term, continuous monitoring of the aircraft radiation environment. RaD-X was successfully launched from Fort Sumner, New Mexico (34.5 N, 104.2 W), on 25 September 2015. Over 18 h of science data were obtained from a total of four different type dosimeters at altitudes above 20 km. The RaD-X flight mission was supported by laboratory radiation exposure testing of the balloon flight dosimeters and also by coordinated radiation measurements taken on ER-2 and commercial aircraft. This paper provides the science background and motivation for the RaD-X flight mission, a brief description of the balloon flight profile and the supporting aircraft flights, and a summary of the articles included in the RaD-X special collection and their contributions to the science goals of the RaD-X mission.
Development of a Compact Efficient Cooling Pump for Space Suit Life Support Systems
NASA Technical Reports Server (NTRS)
vanBoeyen, Roger W.; Reeh, Jonathan A.; Trevino, Luis
2008-01-01
With the increasing demands placed on extravehicular activity (EVA) for the International Space Station (ISS) assembly and maintenance, along with planned lunar and Martian missions, the need for increased human productivity and capability becomes ever more critical. This is most readily achieved by reduction in space suit weight and volume, and increased hardware reliability, durability, and operating lifetime. Considerable progress has been made with each successive generation of space suit design; from the Apollo A7L suit, to the current Shuttle Extravehicular Mobile Unit (EMU) suit, and the next generation Constellation Space Suit Element (CSSE). However, one area of space suit design which has continued to lag is the fluid pump used to drive the water cooling loop of the Primary Life Support System (PLSS). The two main types of fluid pumps typically used in space applications are rotodynamic pumps (pumping is achieved through a rotary vaned impeller) and displacement pumps (which includes rotary and diaphragm pumps). The rotating and moving parts found in the pumps and electric motor add significantly to the susceptibility to wear and friction, thermal mismatch, and complexity of the pumps. Electric motor-driven pumps capable of achieving high operational reliability are necessarily large, heavy, and energy inefficient. This report describes a development effort conducted for NASA by Lynntech, Inc., who recently demonstrated the feasibility of an electrochemically-driven fluid cooling pump. With no electric motor and minimal lightweight components, an electrochemically-driven pump is expected to be significantly smaller, lighter and achieve a longer life time than conventional rotodynamic and displacement pumps. By employing sulfonated polystyrene-based proton exchange membranes, rather than conventional Nafion membranes, a significant reduction in the actuator power consumption was demonstrated. It was also demonstrated that these membranes possess the necessary mechanical strength, durability, and temperature range for long life space operation. The preliminary design for a Phase II prototype pump compares very favorably to the fluid cooling pumps currently used in space suit portable life support systems (PLSS). Characteristics of the electrochemically-driven pump are described and the benefits of the technology as a replacement for electric motor pumps in mechanically pumped single-phase fluid loops (MPFLs) is discussed.
Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter.
Kim, Jin Woo; Kim, Byung Moon; Park, Keun Young; Kim, Dong Joon; Kim, Dong Ik
2016-05-01
Utilization of a dual-lumen balloon may improve Onyx penetration into isolated dural arteriovenous fistulas (i-DAVFs). To compare the results of Onyx embolization using a dual-lumen balloon with those using a non-balloon catheter for i-DAVFs. Twenty-nine patients underwent Onyx embolization for i-DAVFs using a non-balloon (n = 14) or a dual-lumen balloon catheter (n = 15). Since its introduction, a dual-lumen balloon catheter has been preferred. We compared the dual-lumen balloon group with the non-balloon catheter group regarding angiographic outcome, treatment-related complications, total procedural time, Onyx injection time, and the number of feeders requiring embolization. The dual-lumen balloon group showed complete occlusion of i-DAVFs in 13 and near-complete in 2 patients, while the non-balloon group showed complete occlusion in 5, near-complete in 5, and incomplete in 4 patients (P < .05). Treatment-related complications occurred in 2 patients: 1 in the non-balloon group and 1 in the dual-lumen balloon group. The mean total procedural time was 62 ± 32 minutes in the dual-lumen balloon and 171 ± 88 minutes in the non-balloon group (P < .05). The mean Onyx injection time was 10 ± 6 minutes in the dual-lumen balloon and 49 ± 32 minutes in the non-balloon group (P < .05). The median number of feeders requiring embolization was 1 (range, 1-3) in the dual-lumen balloon and 2 (range, 1-4) in the non-balloon group (P < .05). Utilization of a dual-lumen balloon catheter for Onyx embolization of i-DAVF seemed to significantly increase the immediate complete occlusion rate and decrease total procedural time, Onyx injection time, and number of feeders requiring embolization.
NASA Technical Reports Server (NTRS)
Houtas, Franzeska; Teets, Edward H., Jr.
2010-01-01
A comparison study by the National Aeronautics and Space Administration Dryden Flight Research Center, Edwards, CA and the Naval Post Graduate School Center for Interdisciplinary Remotely-Piloted Aircraft Studies, Marina, CA was conducted to show the advantages of an airborne wind profiling lidar system in reducing drift uncertainty along a reentry vehicle descent trajectory. This effort was in support of the once planned Orion Crew Exploration Vehicle ground landing. A Twin Otter Doppler Wind Lidar was flown on multiple flights along the approximate ground track of an ascending weather balloons launched from the Marina Municipal Airport. The airborne lidar used was a 5-milli-Joules, 2-micron infrared laser with a 10-centimeter telescope and a two-axis scanner. Each lidar wind profile contains data for an altitude range between the surface and flight altitude of 2,700 meters, processed on board every 20 seconds. In comparison, a typical weather balloon would traverse that same altitude range with a similar data set available in approximately 15-20 minutes. These tests were conducted on November 15 & 16, 2007. Results comparing the balloon and a 10 minute multiple lidar profile averages show a best case absolute difference of 0.18 m/s (0.35 knots) in speed and 1 degree in direction during light and variable (less than 5 knots, without constant direction) wind conditions. These limited test results indicated a standard deviation wind velocity and direction differences of 0.71 m/s (1.3 knots) and 7.17 degrees for 1800Z, and 0.70 m/s (1.3 knots) and 6.79 degrees, outside of cloud layer.
Use of Mechanical Circulatory Support in Percutaneous Coronary Intervention in the United States
Khera, Rohan; Cram, Peter; Vaughan-Sarrazin, Mary; Horwitz, Phillip A.; Girotra, Saket
2015-01-01
Percutaneous ventricular assist devices (PVADs) and intra-aortic balloon pump (IABP) are used to provide mechanical circulatory support (MCS) for high-risk percutaneous coronary intervention (PCI). Contemporary trends in their utilization and impact on in-hospital mortality are not known. Using the National Inpatient Sample (2004–2012), we identified 5031 patients who received a PVAD and 122,333 who received an IABP on the same day as PCI using ICD9 codes. Utilization of MCS increased from 1.3% of all PCIs in 2004 to 3.4% in 2012 (P trend<0.001), with increase in the use of both PVAD (<1/10000 PCIs [2004–2007] to 38/10000 [2012]) and IABP (132/10000 PCIs [2004] to 299/10000[2012] P<0.0001 for both). PVAD recipients were older (69 vs. 65 years), more likely to have heart failure (68% vs. 41%), chronic kidney disease (27% vs. 11%, P<0.001 for all), and be admitted electively (30% vs. 11%), but less likely to have AMI (52% vs. 90%), cardiogenic shock (23% vs. 50%) or need mechanical ventilation (16% vs. 29%) compared to IABP recipients. Unadjusted in-hospital mortality was lower in PVAD compared to IABP recipients (12.8% vs. 20.9%, P<0.001). However, in propensity-matched analyses (1:2), in-hospital mortality was similar in both groups (odds ratio 0.88, 95% CI 0.70–1.09). In conclusion, there has been a marked increase in the utilization of MCS in patients undergoing PCI. Unadjusted mortality with use of PVADs is lower than IABP but may be due to their selective use in lower-risk patients. Randomized trials are necessary to establish their effectiveness in supporting high-risk PCI. PMID:26547292
Romeo, Francesco; Acconcia, Maria Cristina; Sergi, Domenico; Romeo, Alessia; Francioni, Simona; Chiarotti, Flavia; Caretta, Quintilio
2016-01-01
AIM: To assess the impact of percutaneous cardiac support in cardiogenic shock (CS) complicating acute myocardial infarction (AMI), treated with percutaneous coronary intervention. METHODS: We selected all of the studies published from January 1st, 1997 to May 15st, 2015 that compared the following percutaneous mechanical support in patients with CS due to AMI undergoing myocardial revascularization: (1) intra-aortic balloon pump (IABP) vs Medical therapy; (2) percutaneous left ventricular assist devices (PLVADs) vs IABP; (3) complete extracorporeal life support with extracorporeal membrane oxygenation (ECMO) plus IABP vs IABP alone; and (4) ECMO plus IABP vs ECMO alone, in patients with AMI and CS undergoing myocardial revascularization. We evaluated the impact of the support devices on primary and secondary endpoints. Primary endpoint was the inhospital mortality due to any cause during the same hospital stay and secondary endpoint late mortality at 6-12 mo of follow-up. RESULTS: One thousand two hundred and seventy-two studies met the initial screening criteria. After detailed review, only 30 were selected. There were 6 eligible randomized controlled trials and 24 eligible observational studies totaling 15799 patients. We found that the inhospital mortality was: (1) significantly higher with IABP support vs medical therapy (RR = +15%, P = 0.0002); (2) was higher, although not significantly, with PLVADs compared to IABP (RR = +14%, P = 0.21); and (3) significantly lower in patients treated with ECMO plus IABP vs IABP (RR = -44%, P = 0.0008) or ECMO (RR = -20%, P = 0.006) alone. In addition, Trial Sequential Analysis showed that in the comparison of IABP vs medical therapy, the sample size was adequate to demonstrate a significant increase in risk due to IABP. CONCLUSION: Inhospital mortality was significantly higher with IABP vs medical therapy. PLVADs did not reduce early mortality. ECMO plus IABP significantly reduced inhospital mortality compared to IABP. PMID:26839661
Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.
Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson
2018-05-10
The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.
Bottom head to shell junction assembly for a boiling water nuclear reactor
Fife, Alex Blair; Ballas, Gary J.
1998-01-01
A bottom head to shell junction assembly which, in one embodiment, includes an annular forging having an integrally formed pump deck and shroud support is described. In the one embodiment, the annular forging also includes a top, cylindrical shaped end configured to be welded to one end of the pressure vessel cylindrical shell and a bottom, conical shaped end configured to be welded to the disk shaped bottom head. Reactor internal pump nozzles also are integrally formed in the annular forging. The nozzles do not include any internal or external projections. Stubs are formed in each nozzle opening to facilitate welding a pump housing to the forging. Also, an upper portion of each nozzle opening is configured to receive a portion of a diffuser coupled to a pump shaft which extends through the nozzle opening. Diffuser openings are formed in the integral pump deck to provide additional support for the pump impellers. The diffuser opening is sized so that a pump impeller can extend at least partially therethrough. The pump impeller is connected to the pump shaft which extends through the nozzle opening.
Bottom head to shell junction assembly for a boiling water nuclear reactor
Fife, A.B.; Ballas, G.J.
1998-02-24
A bottom head to shell junction assembly which, in one embodiment, includes an annular forging having an integrally formed pump deck and shroud support is described. In the one embodiment, the annular forging also includes a top, cylindrical shaped end configured to be welded to one end of the pressure vessel cylindrical shell and a bottom, conical shaped end configured to be welded to the disk shaped bottom head. Reactor internal pump nozzles also are integrally formed in the annular forging. The nozzles do not include any internal or external projections. Stubs are formed in each nozzle opening to facilitate welding a pump housing to the forging. Also, an upper portion of each nozzle opening is configured to receive a portion of a diffuser coupled to a pump shaft which extends through the nozzle opening. Diffuser openings are formed in the integral pump deck to provide additional support for the pump impellers. The diffuser opening is sized so that a pump impeller can extend at least partially therethrough. The pump impeller is connected to the pump shaft which extends through the nozzle opening. 5 figs.
Surgical treatment for Ellis type 3 coronary perforation during percutaneous catheter intervention.
Totsugawa, Toshinori; Kuinose, Masahiko; Yoshitaka, Hidenori; Katayama, Keijiro; Tsushima, Yoshimasa; Ishida, Atsuhisa; Chikazawa, Genta; Hiraoka, Arudo
2012-01-01
Coronary perforation (CP) is a rare, but sometimes lethal, complication of percutaneous catheter intervention (PCI). We reviewed surgically-treated cases of type 3 CP during PCI. From 2007 to 2010, 5 patients underwent surgical repair for type 3 CP (3 men, 2 women; mean age, 74 years). The mean number of diseased coronary branches was 2.6 and the mean SYNTAX score was 45. The target lesions were the left anterior descending artery in 4 cases and the right coronary artery in 1 case. Types of American Heart Association/American College of Cardiology classification were type B2 in only one case and type C in 4 cases. The causes of perforation were balloon inflation in 4 patients and rotational atherectomy in 1 patient. The in-hospital mortality rate was 20%. In the cases of CP associated with balloon inflation, coronary lacerations were so severe that re-bleeding occurred even if the covered stent could temporarily achieve hemostasis, and percutaneous cardiopulmonary support and emergency surgery were required. CP induced by balloon inflation tends to result in a serious condition compared with rotablator-induced CP. Surgery should be immediately performed even after covered stent implantation if there is any possibility of re-bleeding in the case of balloon-induced type 3 CP.
Venus cloud bobber mission: A long term survey of the Venusian surface
NASA Technical Reports Server (NTRS)
Wai, James; Derengowski, Cheryl; Lautzenhiser, Russ; Emerson, Matt; Choi, Yongho
1994-01-01
We have examined the Venus Balloon concept in order to further develop the ideas and concepts behind it, and to creatively apply them to the design of the major Venus Balloon components. This report presents our models of the vertical path taken by the Venus Balloon and the entry into Venusian atmosphere. It also details our designs of the balloon, gondola, heat exchanger, power generator, and entry module. A vehicle is designed for a ballistic entry into the Venusian atmosphere, and an atmospheric model is created. The model is then used to set conditions. The shape and material of the vehicle are optimized, and the dimensions of the vehicle are then determined. Equipment is chosen and detailed that will be needed to collect and transmit information and control the mission. A gondola is designed that will enable this sensitive electronic equipment to survive in an atmosphere of very high temperature and pressure. This shape and the material of the shell are optimized, and the size is minimized. Insulation and supporting structures are designed to protect the payload equipment and to minimize mass. A method of cooling the gondola at upper altitudes was established. Power needs of the gondola equipment are determined. Power generation options are discussed and two separate thermoelectric generation models are outlined.
Palmers, Pieter-Jan; Maeremans, Joren; Meyer-Gessner, Markus; Bataille, Yoann; Dens, Joseph
2017-04-30
BACKGROUND Retrograde advancement of microcatheters through septal/epicardial connectors can be challenging. Although several tricks might help to do so (e.g., balloon trap of retro wire in second guiding, balloon trap of retro wire in native coronary artery, and use of antegrade extension to approximate the antegrade conduit to the retrograde gear), these tricks cannot always be applied, especially in patients with poor access. Also, puncturing, knuckling, and crossing of the distal CTO cap (or the aorta as described in 1 of the cases) sometimes needs a lot of backup of the microcatheter. CASE REPORT We describe 3 cases in which we used a novel telescopic technique with 5F Guidion (IMDS®) supported retrograde Corsair (Asahi®) advancement in complex CTO lesions. CONCLUSIONS The telescopic Corsair in 5F Guidion may offer the support needed to end successfully in these situations.
Balloons on Ice: Launch # 2 takes flight in Antarctica
2017-12-08
The second of three missions as part of NASA’s Antarctica Long Duration Balloon Flight Campaign was successfully launched at 8:10 a.m. EDT, Dec. 2. The Antarctic Impulsive Transient Antenna (ANITA) from the University of Hawaii at Manoa was launched from Antarctica’s Ross Ice Shelf near McMurdo Station with support from the National Science Foundation’s United States Antarctic Program. Scientists will use ANITA’s instruments to study the reactions in the core of stars and as they explode via the release of neutrinos that travel to Earth and interact with the Antarctica ice. More: go.nasa.gov/2ghR6Le
Alsamhi, Saeed Hamood; Ansari, Mohd Samar; Ma, Ou; Almalki, Faris; Gupta, Sachin Kumar
2018-05-23
The actions taken at the initial times of a disaster are critical. Catastrophe occurs because of terrorist acts or natural hazards which have the potential to disrupt the infrastructure of wireless communication networks. Therefore, essential emergency functions such as search, rescue, and recovery operations during a catastrophic event will be disabled. We propose tethered balloon technology to provide efficient emergency communication services and reduce casualty mortality and morbidity for disaster recovery. The tethered balloon is an actively developed research area and a simple solution to support the performance, facilities, and services of emergency medical communication. The most critical requirement for rescue and relief teams is having a higher quality of communication services which enables them to save people's lives. Using our proposed technology, it has been reported that the performance of rescue and relief teams significantly improved. OPNET Modeler 14.5 is used for a network simulated with the help of ad hoc tools (Disaster Med Public Health Preparedness. 2018;page 1 of 8).
Why bundled payments could drive innovation: an example from interventional oncology.
Steele, Joseph R; Jones, A Kyle; Ninan, Elizabeth P; Clarke, Ryan K; Odisio, Bruno C; Avritscher, Rony; Murthy, Ravi; Mahvash, Armeen
2015-03-01
Some have suggested that the current fee-for-service health care payment system in the United States stifles innovation. However, there are few published examples supporting this concept. We implemented an innovative temporary balloon occlusion technique for yttrium 90 radioembolization of nonresectable liver cancer. Although our balloon occlusion technique was associated with similar patient outcomes, lower cost, and faster procedure times compared with the standard-of-care coil embolization technique, our technique failed to gain widespread acceptance. Financial analysis revealed that because the balloon occlusion technique avoided a procedural step associated with a lucrative Current Procedural Terminology billing code, this new technique resulted in a significant decrease in hospital and physician revenue in the current fee-for-service payment system, even though the new technique would provide a revenue enhancement through cost savings in a bundled payment system. Our analysis illustrates how in a fee-for-service payment system, financial disincentives can stifle innovation and advancement of health care delivery. Copyright © 2015 by American Society of Clinical Oncology.
Long-Duration, Balloon-Borne Observations of Cosmic Microwave Background Anisotropy
NASA Technical Reports Server (NTRS)
1997-01-01
Funds from this grant were used to support the continuing development of BOOMERANG, a 1.3 m, balloon-borne, attitude-stabilized telescope designed to measure the anisotropy of the Cosmic Microwave Background (CMB) on angular scales of 12 min to 10 degrees. By the end of the funding period covered by this grant, the fabrication of most of the BOOMERANG sub-systems was completed, and integration and test of the payload at Caltech had begun. The project was continued under a new grant from NASA and continuing funding from the NSF. Payload integration and test was completed in April, 1997. A campaign to Palestine, Texas, resulted in two test flights during 1997. A flight on August 12, 1997 was terminated on ascent due to a leaky balloon. The payload was successfully recovered, refurbished, and flown again on August 29, 1997. The second flight was completely successful, and qualified the payload for an LDB flight from McMurdo Stn., Antarctica, in December 1998.
Telescope Systems for Balloon-Borne Research
NASA Technical Reports Server (NTRS)
Swift, C. (Editor); Witteborn, F. C. (Editor); Shipley, A. (Editor)
1974-01-01
The proceedings of a conference on the use of balloons for scientific research are presented. The subjects discussed include the following: (1) astronomical observations with balloon-borne telescopes, (2) orientable, stabilized balloon-borne gondola for around-the-world flights, (3) ultraviolet stellar spectrophotometry from a balloon platform, (4) infrared telescope for balloon-borne infrared astronomy, and (5) stabilization, pointing, and command control of balloon-borne telescopes.
Development of a compact, sealless, tripod supported, magnetically driven centrifugal blood pump.
Yuhki, A; Nogawa, M; Takatani, S
2000-06-01
In this study, a tripod supported sealless centrifugal blood pump was designed and fabricated for implantable application using a specially designed DC brushless motor. The tripod structure consists of 3 ceramic balls mounted at the bottom surface of the impeller moving in a polyethylene groove incorporated at the bottom pump casing. The follower magnet inside the impeller is coupled to the driver magnet of the motor outside the bottom pump casing, thus allowing the impeller to slide-rotate in the polyethylene groove as the motor turns. The pump driver has a weight of 230 g and a diameter of 60 mm. The acrylic pump housing has a weight of 220 g with the priming volume of 25 ml. At the pump rpm of 1,000 to 2,200, the generated head pressure ranged from 30 to 150 mm Hg with the maximum system efficiency being 12%. When the prototype pump was used in the pulsatile mock loop to assist the ventricle from its apex to the aorta, a strong correlation was obtained between the motor current and bypass flow waveforms. The waveform deformation index (WDI), defined as the ratio of the fundamental to the higher order harmonics of the motor current power spectral density, was computed to possibly detect the suction occurring inside the ventricle due to the prototype centrifugal pump. When the WDI was kept under the value of 0.20 by adjusting the motor rpm, it was successful in suppressing the suction due to the centrifugal pump in the ventricle. The prototype sealless, centrifugal pump together with the control method based on the motor current waveform analysis may offer an intermediate support of the failing left or right ventricle bridging to heart transplantation.
Development of mechanical circulatory support devices in China.
Wang, Wei; Zhu, De-Ming; Ding, Wen-Xiang
2009-11-01
Myocardial dysfunction leading to low cardiac output syndrome is a common clinical pathophysiological state. Currently, the use of mechanical circulatory support (MCS) is an essential aspect of the treatment of patients with cardiac failure. Several groups in China are engaged in the design and development of MCS devices. These devices can be classified as pulsatile, rotary, and total artificial heart (TAH). There are two types of pulsatile pump, which are driven by air (pneumatic). One of these pumps, the Luo-Ye pump, has been used clinically for short-term support since 1998. The other is a push-plate left ventricular device, which has a variable rate mode. Various rotary devices are classified into axial and centrifugal pumps, depending on the impeller geometry. Most rotary pumps are based on the maglev principle, and some types have been used clinically. Others are still being studied in the laboratory or in animal experiments. Furthermore, certain types of total implantable pump, such as the UJS-III axial pump and the UJS-IV aortic valvo-pump, have been developed. Only one type of TAH has been developed in China. The main constituents of this artificial heart are two axial pumps, two reservoir tanks mimicking the right and left atria, flow meters, two pressure gauges, and a resistance adaptor. Although the development of mechanical assist devices in China is still in a nascent stage, a number of different types of MCS devices are currently being studied.
Taenaka, Yoshiyuki; Wakisaka, Yoshinari; Masuzawa, Toru; Tatsumi, Eisuke; Toda, Koichi; Miyazaki, Koji; Eya, Kazuhiro; Baba, Yuzo; Nakatani, Takeshi; Ohno, Takashi; Nishimura, Takashi; Takano, Hisateru
1996-05-01
A centrifugal pump with a unique structure has been developed for chronic support. The pump is driven by a magnetic coupling and has no rotating shaft, no seal around the rotating part, and a balancing hole at the center of the impeller and the thrust bearing. The pump was improved in stepwise fashion to realize good antithrombogenicity and low hemolysis. The first pump, the National Cardiovascular Center (NCVC)-O, had an impeller with 4 rectangular and curved vanes; 6 triangularly shaped curved vanes were employed in the second model, the NCVC-1, to reduce trauma to the blood. In the third design, the NCVC-2, the central hole was enlarged, and the thrust bearing shoulder was rounded so that blood washing was enhanced around the impeller; stream lines also were smoothed for improved antithrombogenicity. The hemolytic property of the device was evaluated in vitro with heparinized fresh goat blood; hemolysis indexes of the NCVC-0, -1, and -2 were 0.05, 0.01, and 0.006 g per 100 L, respectively. Antithrombogenicity of the pumps was examined in animal experiments as a left heart bypass device in goats weighing 52-75 kg. Six NCVC-0 pumps were driven for 14 to 33 (22.0 ± 7.6) days in goats receiving the antiplatelet drug cilostazol orally. Four NCVC-I pumps ran for 1 to 80 (28.5 ± 30.6) days with the same drug regimen in 2 cases and with no anticoagulation therapy in 2 cases. After 3 preliminary 1-week tests of NCVC-2 pumps in animals, the pump was installed in 3 goats; 2 pumps were still running on the 182nd and 58th pumping day. Intracorporeal implantation also was attempted successfully. The results indicate that this pump has promising features for chronic support although longer term and additional evaluations are necessary. © 1996 International Society for Artificial Organs.
Taenaka, Y; Wakisaka, Y; Masuzawa, T; Tatsumi, E; Toda, K; Miyazaki, K; Eya, K; Baba, Y; Nakatani, T; Ohno, T; Nishimura, T; Takano, H
1996-06-01
A centrifugal pump with a unique structure has been developed for chronic support. The pump is driven by a magnetic coupling and has no rotating shaft, no seal around the rotating part, and a balancing hole at the center of the impeller and the thrust bearing. The pump was improved in stepwise fashion to realize good antithrombogenicity and low hemolysis. The first pump, the National Cardiovascular Center (NCVC)-0, had an impeller with 4 rectangular and curved vanes; 6 triangularly shaped curved vanes were employed in the second model, the NCVC-1, to reduce trauma to the blood. In the third design, the NCVC-2, the central hole was enlarged, and the thrust bearing shoulder was rounded so that blood washing was enhanced around the impeller; stream lines also were smoothed for improved antithrombogenicity. The hemolytic property of the device was evaluated in vitro with heparinized fresh goat blood; hemolysis indexes of the NCVC-0, -1, and -2 were 0.05, 0.01, and 0.006 g per 100 L, respectively. Antithrombogenicity of the pumps was examined in animal experiments as a left heart bypass device in goals weighing 52-75 kg. Six NCVC-0 pumps were driven for 14 to 33 (22.0 +/- 7.6) days in goats receiving the antiplatelet drug cilostazol orally. Four NCVC-1 pumps ran for 1 to 80 (28.5 +/- 30.6) days with the same drug regimen in 2 cases and with no anticoagulation therapy in 2 cases. After 3 preliminary 1-week tests of NCVC-2 pumps in animals, the pump was installed in 3 goats; 2 pumps were still running on the 182nd and 58th pumping day. Intracorporeal implantation also was attempted successfully. The results indicate that this pump has promising features for chronic support although longer term and additional evaluations are necessary.
Modified ECC ozone sonde for long-duration flights aboard isopicnic drifting balloons
NASA Astrophysics Data System (ADS)
Gheusi, Francois; Durand, Pierre; Verdier, Nicolas; Dulac, François; Attié, Jean-Luc; Commun, Philippe; Barret, Brice; Basdevant, Claude; Clénet, Antoine; Fontaine, Alain; Jambert, Corinne; Meyerfeld, Yves; Roblou, Laurent; Tocquer, Flore
2015-04-01
Since few years, the French space agency CNES has developed boundary-layer pressurized balloons (BLPB) with the capability to transport scientific payloads at isopicnic level over very long distances and durations (up to several weeks in absence of navigation limits). However, the autonomy of conventional electrochemical concentration cell (ECC) ozone sondes, that are widely used for tropospheric and stratospheric soundings, is limited to few hours due to power consumption and electrolyte evaporation (owing to air bubbling in the cathode solution). In collaboration with the French research community, CNES has developed a new ozone payload suited for long duration flights aboard BLPB. The mechanical elements (Teflon pump and motor) and the electrochemical cell of conventional ECC sondes have been kept but the electronic implementation is entirely new. The main feature is the possibility of programming periodic measurement sequences -- with possible remote control during the flight. To increase the ozone sonde autonomy, a strategy has been adopted of short measurement sequences (typically 2-3 min) regularly spaced in time (e.g. every 15 min, which is usually sufficient for air quality studies). The rest of the time, the sonde is at rest (pump motor off). The response time of an ECC sonde to an ozone concentration step is below one minute. Consequently, the measurement sequence is typically composed of a one-minute spin-up period after the pump has been turned on, followed by a one- to two-minute acquisition period. All time intervals can be adjusted before and during the flight. Results of a preliminary ground-based test in spring 2012 are first presented. The sonde provided correct ozone concentrations against a reference UV analyzer every 15 minutes during 4 days. Then we illustrate results from 16 BLBP flights launched in the low troposphere over the Mediterranean during summer field campaings in 2012 and 2013 (TRAQA and ChArMEx programmes). BLPB drifting altitudes were in the range 0.25-3.2 km. The longest flight lasted more than 32 hours and covered more than 1000 km between Minorca and the limit of the authorized flight area south of Malta. During some flights, satisfying comparisons were obtained relatively to independent measurements close in time and space. The obtained quasi-Lagrangian measurements allow an evaluation of the ozone production/destruction rate as a function of the solar radiation (also measured onboard, as well as standard weather variables) that will be helpful to test chemistry-transport models.
ERIC Educational Resources Information Center
Balloon Council, Washington, DC.
This document provides background information on balloons including: (1) the history of balloons; (2) balloon manufacturing; (3) biodegradability; (4) the fate of latex balloons; and (5) the effect of balloons on the rainforest and sea mammals. Also included as part of this instructional kit are four fun experiments that allow students to…
NASA Astrophysics Data System (ADS)
Saito, Yoshitaka; Nakashino, Kyoichi; Akita, Daisuke; Matsushima, Kiyoho; Shimadu, Shigeyuki; Goto, Ken; Hashimoto, Hiroyuki; Matsuo, Takuma
2016-07-01
A light super-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m^{3} balloon. Beginning from a demonstration test of the net-balloon with a 10 m^{3} balloon in 2010, we have been polished the net-balloon through ground inflation tests and flight tests, including a flight test of a 3,000 m ^{3} balloon in the tandem balloon configuration with a 15,000 m^{3} zero-pressure balloon in 2012, and a flight test of a 10 m^{3} balloon in the tandem balloon configuration with a 2 kg rubber balloon in 2013, as reported in the last COSPAR. In 2014, we developed a 5,000 m^{3} balloon and performed a ground inflation test to find that the balloon burst from a lip panel for termination with a differential pressure of 425 Pa. It was due to a stress concentration at the edge of a thick tape attached along the termination mechanism. In 2015, we modified the balloon by adding tapes on the lip panel to avoid the stress concentration, and also shorten the net length to leave some margin of the film and performed a ground inflation test again to find the balloon showed asymmetrical deployment and burst from the edge of the net with a differential pressure of 348 Pa. We consider it is due to the margin of the film along the circumferential direction, and proposed a gore shape which circumference length is kept as determined by the pumpkin shape of the balloon but setting meridian length longer than that. We developed a 10 m^{3} balloon with the gore design to find that the balloon deployed symmetrically and showed the burst pressure of 10,000 Pa. In 2016, we are going to develop a 2,000 m^{3} balloon with the gore design and perform its ground inflation test. In this paper, we are going to report its result with the sequence of the development.
NASA Astrophysics Data System (ADS)
Ivey, M.; Dexheimer, D.; Hardesty, J.; Lucero, D. A.; Helsel, F.
2015-12-01
The U.S. Department of Energy (DOE), through its scientific user facility, the Atmospheric Radiation Measurement (ARM) facilities, provides scientific infrastructure and data to the international Arctic research community via its research sites located on the North Slope of Alaska. DOE has recently invested in improvements to facilities and infrastructure to support operations of unmanned aerial systems for science missions in the Arctic and North Slope of Alaska. A new ground facility, the Third ARM Mobile Facility, was installed at Oliktok Point Alaska in 2013. Tethered instrumented balloons were used to make measurements of clouds in the boundary layer including mixed-phase clouds. A new Special Use Airspace was granted to DOE in 2015 to support science missions in international airspace in the Arctic. Warning Area W-220 is managed by Sandia National Laboratories for DOE Office of Science/BER. W-220 was successfully used for the first time in July 2015 in conjunction with Restricted Area R-2204 and a connecting Altitude Reservation Corridor (ALTRV) to permit unmanned aircraft to operate north of Oliktok Point. Small unmanned aircraft (DataHawks) and tethered balloons were flown at Oliktok during the summer and fall of 2015. This poster will discuss how principal investigators may apply for use of these Special Use Airspaces, acquire data from the Third ARM Mobile Facility, or bring their own instrumentation for deployment at Oliktok Point, Alaska. The printed poster will include the standard DOE funding statement.
Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M
Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.
Properties of nylon 12 balloons after thermal and liquid carbon dioxide treatments.
Ro, Andrew J; Davé, Vipul
2013-03-01
Critical design attributes of angioplasty balloons include the following: tear resistance, high burst pressures, controlled compliance, and high fatigue. Balloons must have tear resistance and high burst pressures because a calcified stenosis can be hard and nominal pressures of up to 16 atm can be used to expand the balloon. The inflated balloon diameter must be a function of the inflation pressure, thus compliance is predictable and controlled. Reliable compliance is necessary to prevent damage to vessel walls, which may be caused by over-inflation. Balloons are often inflated multiple times in a clinical setting and they must be highly resistant to fatigue. These design attributes are dependent on the mechanical properties and polymer morphology of the balloon. The effects of residual stresses on shrinkage, crystallite orientation, balloon compliance, and mechanical properties were studied for angioplasty nylon 12 balloons. Residual stresses of these balloons were relieved by oven heat treatment and liquid CO2 exposure. Residual stresses were measured by quantifying shrinkage at 80 °C of excised balloon samples using a dynamic mechanical analyzer. Shrinkage was lower after oven heat treatment and liquid CO2 exposure compared to the as-received balloons, in the axial and radial directions. As-received, oven heat treated, and liquid CO2-exposed balloon samples exhibited similar thermal properties (T(g), T(m), X(t)). Crystallite orientation was not observed in the balloon cylindrical body using X-ray scattering and polarized light microscopy, which may be due to balloon fabrication conditions. Significant differences were not observed between the stress-strain curves, balloon compliance, and average burst pressures of the as-received, oven heat treated, and liquid CO2-exposed balloons. Copyright © 2012 Elsevier B.V. All rights reserved.
Soltani, Sajjad; Kaufmann, Friedrich; Vierecke, Juliane; Kretzschmar, Alexandra; Hennig, Ewald; Stein, Julia; Hetzer, Roland; Krabatsch, Thomas; Potapov, Evgenij V
2015-06-01
The implantable continuous-flow left ventricular assist devices (LVADs) HeartMate II (HM II) and HeartWare HVAD (HW) underwent design modifications. The impact of these changes on life-threatening pump malfunctions was evaluated. We retrospectively analysed pump malfunctions due to thrombosis or cable damage in patients supported with primarily implanted HM II (n = 191) and HW (n = 347), separated into patients supported with the old and new pump designs. In 2010, the cable strain relief of the HM II device was improved (132 patients with old and 79 with new) and sealed grafts were introduced (68 patients with sealed inflow connector and outflow graft and 125 without). In 2011, titanium sintering of the inflow cannula of HW pumps was introduced (137 patients with a non-sintered and 210 with a sintered inflow cannula). The median support time was 1.12 (0-6.1) years for all HM II and 0.59 (0-4.2) years for all HW patients. The cumulative rate of events per patient-year (EPPY) was 0.11 in HM II patients, compared with 0.09 EPPY in HW patients (P = 0.32). After introduction of the new cable design, incidence of cable damage in HM II patients dropped from 0.06 to 0 EPPY (P = 0.03), whereas pump thrombosis increased from 0.02 to 0.14 EPPY (P < 0.001) after the sealed graft was introduced. Pump thrombosis occurred in 4% of patients supported with HW with a sintered inflow cannula vs 15% with a non-sintered pump; the incidence changed from 0.10 to 0.07 EPPY in sintered pumps (P = 0.45). Kaplan-Meier analysis showed no differences over a period of 2.5 years for events when the HM II cohort with sealed graft and new cable design (n = 68) was compared with the HW group with a sintered cannula (P = 0.14). The modified cable strain relief of the HM II pump and the sintering of the inflow cannula of the HW pump demonstrated a significant reduction in the incidence of life-threatening pump-related complications, whereas the sealed inflow connector and outflow graft seem to be associated with a higher incidence of pump thrombosis. However, the overall incidence of pump-related complications after the latest design changes was similar for both pumps over a 2.5-year period. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
A stress index model for ascending balloons
NASA Technical Reports Server (NTRS)
Smith, I. S.
1986-01-01
Attention is given to the development on the part of NASA of a simplified stress 'index' model to establish the relative stress magnitudes along a balloon's gore position as a function of altitude. Application of this model to several hundred balloon flights showed a good correlation between balloon failure rate and stress 'index' level. This model can be used during the balloon design process to lower the levels of stress in the balloon. By increasing the wall thickness of the balloon, adding caps, lengthening caps, or using external caps, lower stress can be accomplished. As a result, in January 1985, the NASA Balloon Program established a stress index specification to limit the design and flight stresses for NASA balloons.
Soyama, Hiroaki; Miyamoto, Morikazu; Sasa, Hidenori; Ishibashi, Hiroki; Yoshida, Masashi; Nakatsuka, Masaya; Takano, Masashi; Furuya, Kenichi
2017-09-01
To evaluate the effectiveness of routine rapid insertion of a Bakri balloon during cesarean section for placenta previa based on a retrospective control study. Women with singleton pregnancies who underwent cesarean section for placenta previa at our institution between 2003 and 2016 were enrolled. Between 2015 and 2016, women who routinely underwent balloon tamponade during cesarean section were defined as the balloon group. Between 2003 and 2014, women who underwent no hemostatic procedures except balloon tamponade were defined as the non-balloon group. The clinical outcomes of the two groups were retrospectively analyzed. Of the 266 women with placenta previa, 50 were in the balloon group and 216 were in the non-balloon group. The bleeding amounts were significantly smaller in the balloon group than in the non-balloon group: intraoperative bleeding (991 vs. 1250 g, p < 0.01), postoperative bleeding (62 vs. 150 g, p < 0.01), and total bleeding (1066 vs. 1451 g, p < 0.01). Furthermore, the mean surgical duration was shorter in the balloon group than the non-balloon group (30 vs. 50 min, p < 0.01). In the balloon group, five patients suffered from increasing hemorrhage due to prolapse of the balloon from the uterus after the operation, but the hemorrhage was controlled by balloon re-insertion without additional hemostatic procedures. This study demonstrated that the routine rapid insertion of Bakri balloon tamponade during cesarean section significantly decreased intra- and postoperative hemorrhage and shortened the surgical duration in women with placenta previa.
21 CFR 870.1350 - Catheter balloon repair kit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...
21 CFR 870.1350 - Catheter balloon repair kit.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...
21 CFR 870.1350 - Catheter balloon repair kit.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...
Status of the NASA Balloon Program
NASA Astrophysics Data System (ADS)
Needleman, H. C.; Nock, R. S.; Bawcom, D. W.
1993-02-01
In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.
Controlled weather balloon ascents and descents for atmospheric research and climate monitoring
Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F.; Hall, Emrys G.; Jordan, Allen F.
2017-01-01
In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth’s surface to about 35 km (3–5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent. PMID:29263765
Controlled weather balloon ascents and descents for atmospheric research and climate monitoring.
Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F; Hall, Emrys G; Jordan, Allen F
2016-01-01
In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth's surface to about 35 km (3-5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent.
Shade, Brandon C; Schiavo, Kellie; Rosenthal, Tami; Connelly, James T; Melchior, Richard W
2016-06-05
Recent advances in blood pump technology have led to an increased use of centrifugal pumps for prolonged extracorporeal membrane oxygenation (ECMO). Data from the Extracorporeal Life Support Organization confirms that many institutions have converted to centrifugal pumps after prior experience with roller pump technology. Centrifugal pump technology is more compact and may generate less heat and hemolysis than a conventional roller pump. Based on the potential advantages of centrifugal pumps, a decision was made institution-wide to convert to centrifugal pump technology in pediatric implementation of ECMO. Based on limited prior experience with centrifugal pumps, a multidisciplinary approach was used to implement this new technology. The new centrifugal pump (Sorin Revolution, Arvada, CO) was intended for ECMO support in the cardiac intensive care unit (CICU), the pediatric intensive care unit (PICU) and the neonatal intensive care unit (NICU). The perfusion team used their knowledge and expertise with centrifugal pumps to create the necessary teaching tools and interactive training sessions for the technical specialists who consisted primarily of registered nurses and respiratory therapists. The first phase consisted of educating all personnel involved in the care of the ECMO patient, followed by patient implementation in the CICU, followed by the PICU and NICU. The institution-wide conversion took several months to complete and was well received among all disciplines in the CICU and PICU. The NICU personnel did use the centrifugal pump circuit, but decided to revert back to using the roller pump technology. A systematic transition from roller pump to centrifugal pump technology with a multidisciplinary team can ensure a safe and successful implementation. © The Author(s) 2016.
NASA Astrophysics Data System (ADS)
Singh, R.; Kim, J.-H.; Jhang, Hogun; Das, S.
2018-03-01
Two-step mode coupling analyses for nonlinear excitation of the ballooning mode (BM) in pedestal plasma by external helical magnetic field perturbation [Resonant Magnetic Perturbations (RMP)] are presented. This technique allows calculating the effect of higher harmonic sidebands generated by interaction of long scale RMP pump and BM. It is shown that RMP field perturbations can modify the BM growth rate and frequency through nonlinear Reynolds stress and magnetic stress. In particular, it is shown that both stresses can efficiently excite high wavenumber BM fluctuations which, in turn, can enhance the transport in the pedestal. Another notable feature of this analysis is the existence of short scale (high- k y ) nonlinear instability at Alfven time scale near the ideal BM threshold boundary.
NASA Technical Reports Server (NTRS)
Hilsenrath, E.; Kirschner, P. T.
1980-01-01
The chemiluminescent rocket ozonesonde utilizing rhodamine-B as a detector and self-pumping for air sampling has been improved. The instrument employs standard meteorological sounding systems and is the only technique available for routine nighttime ozone measurements above balloon altitudes. The chemiluminescent detector, when properly calibrated, is shown to be specific to ozone, stable, and of sufficient sensitivity for accurate measurements of ozone from about 65-20 km. An error analysis indicates that the measured ozone profiles have an absolute accuracy of about + or - 12% and a precision of about + or - 6%. Approximately 20 flights have been conducted for geophysical investigations, while additional flights were conducted with other rocket and satellite ozone soundings for comparisons. In general, these comparisons showed good agreement.
The ferrosilicon process for the generation of hydrogen
NASA Technical Reports Server (NTRS)
Weaver, E R; Berry, W M; Bohnson, V L; Gordon, B D
1920-01-01
Report describes the generation of hydrogen by the reaction between ferrosilicon, sodium hydroxide, and water. This method known as the ferrosilicon method is especially adapted for use in the military field because of the relatively small size and low cost of the generator required to produce hydrogen at a rapid rate, the small operating force required, and the fact that no power is used except the small amount required to operate the stirring and pumping machinery. These advantages make it possible to quickly generate sufficient hydrogen to fill a balloon with a generator which can be transported on a motor truck. This report gives a summary of the details of the ferrosilicon process and a critical examination of the means which are necessary in order to make the process successful.
Gelsomino, Sandro; Lucà, Fabiana; Renzulli, Attilio; Rubino, Antonino S; Romano, Salvatore Mario; van der Veen, Frederik H; Carella, Rocco; Maessen, Joseph G; Gensini, Gian Franco; Lorusso, Roberto
2011-01-01
The evaluation of the impact of intraaortic balloon pump (IABP) on postischemic coronary perfusion and myocardial contractile impairment has been so far limited to early reperfusion phase. Therefore, we analyzed the 24-hour effects of IABP on coronary blood flow (CBF) and left ventricular performance in an animal model of acute myocardial ischemia-reperfusion injury. Healthy swine (n = 20) underwent 120-minute ligation of the left anterior descending coronary artery followed by 24 hours of reperfusion. We randomly assigned the animals to have IABP placed in the descending aorta 5 minutes after reperfusion onset (n = 10) or to undergo no implantation (n = 10). We measured CBF, coronary resistance, cardiac cycle efficiency (CCE), and maximal pressure/time ratio before ischemia was induced and at 30 minutes and 1, 6, 12, and 24 hours after reperfusion began. During diastole, CBF was significantly increased in IABP compared with baseline and controls at all time points (all p < 0.001). This was also true during systole in IABP only for the first hour after reperfusion began. Additionally, both CCE and pressure/time ratio were significantly increased in IABP compared with baseline at 30 minutes and 1 hour after reperfusion began (p < 0.001). IABP was associated with enhanced CBF and cardiac efficiency in a model of acute ischemic-reperfusion injury.
Smedira, Nicholas G; Blackstone, Eugene H; Ehrlinger, John; Thuita, Lucy; Pierce, Christopher D; Moazami, Nader; Starling, Randall C
2015-12-01
Data from 3 institutions revealed an abrupt increase in HeartMate II (Thoratec) pump thrombosis starting in 2011, associated with 48% mortality at 6 months without transplantation or pump exchange. We sought to discover if the increase occurred nationwide in Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) data, and if so (1) determine if accelerated risk continued, (2) identify predictors, (3) investigate institutional variability, and (4) assess mortality after pump thrombosis. From April 2008 to June 2014, 11,123 HeartMate II devices were implanted at 146 institutions. Machine learning, non-parametric Random Forests for Survival was used to explore risk-adjusted thrombosis based on 87 pre-implant and implant variables, including implant date. A total of 995 pumps thrombosed, with risk peaking within weeks of implant. The risk-adjusted increase in pump thrombosis began in 2010, reached a maximum in 2012, and then plateaued at a level that was 3.3-times higher than pre-2010. Pump exchange, younger age, and larger body mass index were important predictors, and institutional variability was largely explained by implant date, patient profile, and duration of support. The probability of death within 3 months after pump thrombosis was 24%. Accelerated risk of HeartMate II thrombosis was confirmed by Interagency Registry for Mechanically Assisted Circulatory Support data, with risk subsequently leveling at a risk-adjusted rate higher than observed pre-2010. This elevated thrombosis risk emphasizes the need for improved mechanical circulatory support systems and post-market surveillance of adverse events. Clinicians cognizant of these new data should incorporate them into their and their patients' expectations and understanding of risks relative to those of transplantation and continued medical therapy. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Investigation of hot air balloon fatalities.
McConnell, T S; Smialek, J E; Capron, R G
1985-04-01
The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.
Development of the Baylor-Nikkiso centrifugal pump with a purging system for circulatory support.
Naito, K; Miyazoe, Y; Aizawa, T; Mizuguchi, K; Tasai, K; Ohara, Y; Orime, Y; Glueck, J; Takatani, S; Noon, G P
1993-07-01
The Baylor-Nikkiso centrifugal pump is a magnetically coupled system with a V-ring seal separating the pump and the actuator chamber. To prevent thrombus formation behind the impeller and to extend the life of the pump to 2 weeks of continuous operation, we incorporated a purging chamber behind the V-ring seal. An external pump connected to this purging chamber infused fluid at a constant rate to wash the shaft-seal area. To evaluate the effectiveness of the purging system, we have carried out biventricular bypass experiments using calves. The purging system was successful in reducing the level of thrombus formation after 2 weeks of operation. The results of these studies confirmed that the Baylor-Nikkiso centrifugal pump with this purging system is suitable for at least 2 weeks of continuous operation as a circulatory support system.
Early outcomes of on-pump versus off-pump coronary artery bypass grafting.
Hussain, Ghulam; Azam, Hammad; Baig, Mirza Ahmad Raza; Ahmad, Naseem
2016-01-01
To see the early post-operative outcomes of off-pump versus on-pump coronary artery bypass graft surgery. This retrospective analytical study was conducted at Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Our Primary outcome variables were; necessity of inotropic support, nonfatal myocardial infarction, ICU stay, nonfatal stroke, new renal failure requiring dialysis and death within 30 days after operation. There were two groups of patients; Group-I (On-pump group) and Group-II (Off-pump Group). SPSS V17 was used for data analysis. Independent sample t-test and Mann Whitney U test were used to compare quantitative Variables. Chi-square test and Fisher's exact test were used to analyze qualitative variables. P-value ≤ 0.05 was considered significant. Three hundred patients were included in this study. There were no significant difference regarding risk factors except hyper-cholestrolemia which was high in off pump group (p-value 0.05). Angiographic and Echocardiographic characteristics e.g. preoperative ejection fraction, LV function grade and severity of CAD was same between the groups. Mortality risk scores and Priority status for surgery were also same. Regarding post-operative outcomes; Post-op CKMB Levels, need and duration of inotropic support, mechanical ventilation time and ICU stay was significantly less in Off-Pump group (p-value 0.001, <0.0001, 0.006, 0.025 and 0.001 resp.). Peri-operative chest drainage was significantly high in On-pump CABG group (p-value 0.027). Incidence of post-op complications was not statistically different between the groups. At 30 days follow-up, Incidence of myocardial infarction, necessity and duration of inotropic support, ICU stay period and peri-operative bleeding were significantly less in off-pump group. The incidence of neurologic, pulmonary and renal complications was same between the off-pump and on-pump groups.
Early outcomes of on-pump versus off-pump coronary artery bypass grafting
Hussain, Ghulam; Azam, Hammad; Baig, Mirza Ahmad Raza; Ahmad, Naseem
2016-01-01
Objectives: To see the early post-operative outcomes of off-pump versus on-pump coronary artery bypass graft surgery. Methods: This retrospective analytical study was conducted at Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Our Primary outcome variables were; necessity of inotropic support, nonfatal myocardial infarction, ICU stay, nonfatal stroke, new renal failure requiring dialysis and death within 30 days after operation. There were two groups of patients; Group-I (On-pump group) and Group-II (Off-pump Group). SPSS V17 was used for data analysis. Independent sample t-test and Mann Whitney U test were used to compare quantitative Variables. Chi-square test and Fisher’s exact test were used to analyze qualitative variables. P-value ≤ 0.05 was considered significant. Results: Three hundred patients were included in this study. There were no significant difference regarding risk factors except hyper-cholestrolemia which was high in off pump group (p-value 0.05). Angiographic and Echocardiographic characteristics e.g. preoperative ejection fraction, LV function grade and severity of CAD was same between the groups. Mortality risk scores and Priority status for surgery were also same. Regarding post-operative outcomes; Post-op CKMB Levels, need and duration of inotropic support, mechanical ventilation time and ICU stay was significantly less in Off-Pump group (p-value 0.001, <0.0001, 0.006, 0.025 and 0.001 resp.). Peri-operative chest drainage was significantly high in On-pump CABG group (p-value 0.027). Incidence of post-op complications was not statistically different between the groups. Conclusions: At 30 days follow-up, Incidence of myocardial infarction, necessity and duration of inotropic support, ICU stay period and peri-operative bleeding were significantly less in off-pump group. The incidence of neurologic, pulmonary and renal complications was same between the off-pump and on-pump groups. PMID:27648039
Clinical experience with the Monorail balloon catheter for coronary angioplasty.
Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W
1988-01-01
The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.
Use of monorail PTCA balloon catheter for local drug delivery.
Trehan, Vijay; Nair, Girish M; Gupta, Mohit D
2007-01-01
We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.
Tsai, Su-Ying
2014-01-01
Although increasing numbers of large companies are complying with demands for a breastfeeding-friendly workplace by providing lactation rooms and breast-pumping breaks, the effectiveness for intention to use breast-pumping breaks to express breast milk among employed mothers is uncertain. To explore the impact of employees' perceived breastfeeding support from the workplace and the benefits of breastfeeding on a woman's intention to use breast-pumping breaks after returning to work, we conducted a survey at a female labor-intensive electronics manufacturer in Taiwan. A structured questionnaire survey was administered to 715 working mothers employed in an electronics manufacturing plant in Tainan Science Park in Southern Taiwan. Questionnaire content included female employee demographics, employment characteristics, and breastfeeding behavior after returning to work, as well as employees' perception of breastfeeding-friendly support and awareness of the benefits of breastfeeding when raising their most recently born child. Higher education (odds ratio [OR] 2.33), non-clean room worksite (OR 1.51), awareness of breast-pumping breaks (OR 4.70), encouragement by colleagues to use breast-pumping breaks (OR 1.76), and greater awareness of the benefits of breastfeeding (OR 1.08) were significant predictors of the use of breast-pumping breaks after returning to work, whereas the perception of inefficiency when using breast-pumping breaks reduced an employed mother's intention to use breast-pumping breaks (OR 0.55). This study finds an association between an appreciation of the benefits provided by the employer and the likelihood of increased usage of breastfeeding breaks. Workplaces and employers can help employed mothers to understand the benefits of breastfeeding, which may increase the intention of the mother to take breast-pumping breaks after returning to work.
Hot-Air Ballooning in Physics Teaching.
ERIC Educational Resources Information Center
Haugland, Ole Anton
1991-01-01
Describes the modern hot-air balloon and the physics of ballooning. Proposes that students construct their own hot-air balloon and presents an experiment calculating the time needed for a balloon to rise to the ceiling of a gymnasium. (MDH)
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-21
... infusion pump stand, which is currently classified as a class I device because it supports the intended use of an infusion pump (class II medical device). A mobile medical app that simply supports the intended...
Development of a Super-Pressure Balloon with an Improved Design
NASA Astrophysics Data System (ADS)
Izutsu, Naoki; Akita, Daisuke; Fuke, Hideyuki; Iijima, Issei; Kato, Yoichi; Kawada, Jiro; Matsushima, Kiyoho; Matsuzaka, Yukihiko; Mizuta, Eiichi; Nakada, Takashi; Nonaka, Naoki; Saito, Yoshitaka; Takada, Atsushi; Tamura, Keisuke; Yamada, Kazuhiko; Yoshida, Tetsuya
A zero-pressure balloon used for scientific observation in the stratosphere has an unmanageable limitation that its floating altitude decreases during a nighttime because of temperature drop of the lifting gas. Since a super-pressure balloon may not change its volume, the lifetime can extend very long. We had introduced so called the ‘lobed-pumpkin’ type of super-pressure balloon that can realize a full-scale long-duration balloon and it will be in practical use in the very near future. As for larger super-pressure balloons, however, we still have some potential difficulties to be resolved. We here propose a new design suitable for a larger super-pressure balloon, which is roughly ‘lobed pumpkin with lobed cylinder’ and can adapt a single design for balloons of a wide range of volumes. Indoor inflation tests were successfully carried out with balloons designed and made by the method. It has been shown that the limit of the resisting pressure differential for a new designed balloon is same as that of a normal lobed-pumpkin balloon.
Development of a 5,000 m(3) super-pressure balloon with a diamond-shaped net
NASA Astrophysics Data System (ADS)
Saito, Yoshitaka; Tanaka, Shigeki; Nakashino, Kyoichi; Matsushima, Kiyoho; Goto, Ken; Furuta, Ryosuke; Domoto, Kodai; Akita, Daisuke; Hashimoto, Hiroyuki
A light super-pressure balloon of which weight will be comparable to the weight of the zero-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m(3) balloon. A flight test of a 3,000 m(3) balloon in the tandem balloon configuration with a 15,000 m(3) zero-pressure balloon was performed in 2012. Although a small gas leak occurred in the super-pressure balloon at the differential pressure of 400 to 500 Pa, the differential pressure reached the highest value of 814 Pa and kept positive through the level flight lasting for 25 minutes due to its slow leakage. To avoid a possible stress concentration to films at the polar area, a new design setting the meridian length of the balloon gore film equal to the length of the net was adopted. A 3-m balloon with the design was developed and its capacity to resist pressure at room temperature and at -30 (°) C was checked through the ground inflation tests. In 2013, a balloon of the same model was launched in the tandem balloon configuration with 2 kg rubber balloons. It was confirmed that the balloon could withstand the maximum differential pressure of 6,280 Pa, could withstand the differential pressure of 5,600 Pa for 2 hours, and there was a small gas leak through a hole with an area of 0.4 mm(2) which was also found in the ground leakage test. These results indicated that the improvement was adequate and there was no problem for the super-pressure balloon to fly in the environment of the stratosphere except for the problem of the small gas leak. In 2014, a flight test of a 5,000 m(3) balloon will be performed. In this paper, after reviewing the method to cover a balloon with a diamond-shaped net, the current status of the development will be reported.
Overview of medical operations for a manned stratospheric balloon flight.
Blue, Rebecca S; Law, Jennifer; Norton, Sean C; Garbino, Alejandro; Pattarini, James M; Turney, Matthew W; Clark, Jonathan B
2013-03-01
Red Bull Stratos was a commercial program designed to bring a test parachutist protected by a full-pressure suit via a stratospheric balloon with a pressurized capsule to 120,000 ft (36,576 m), from which he would freefall and subsequently parachute to the ground. On March 15, 2012, the Red Bull Stratos program successfully conducted a preliminary manned balloon test flight and parachute jump, reaching a final altitude of 71,581 ft (21,818 m). In light of the uniqueness of the operation and medical threats faced, a comprehensive medical plan was needed to ensure prompt and efficient response to any medical contingencies. This report will serve to discuss the medical plans put into place before the first manned balloon flight and the actions of the medical team during that flight. The medical operations developed for this program will be systematically evaluated, particularly, specific recommendations for improvement in future high-altitude and commercial space activities. A multipronged approach to medical support was developed, consisting of event planning, medical personnel, equipment, contingency-specific considerations, and communications. Medical operations were found to be highly successful when field-tested during this stratospheric flight, and the experience allowed for refinement of medical operations for future flights. The lessons learned and practices established for this program can easily be used to tailor a plan specific to other aviation or spaceflight events.
NASA Astrophysics Data System (ADS)
Ivey, M.; Dexheimer, D.; Roesler, E. L.; Hillman, B. R.; Hardesty, J. O.
2016-12-01
The U.S. Department of Energy (DOE) provides scientific infrastructure and data to the international Arctic research community via research sites located on the North Slope of Alaska and an open data archive maintained by the ARM program. In 2016, DOE continued investments in improvements to facilities and infrastructure at Oliktok Point Alaska to support operations of ground-based facilities and unmanned aerial systems for science missions in the Arctic. The Third ARM Mobile Facility, AMF3, now deployed at Oliktok Point, was further expanded in 2016. Tethered instrumented balloons were used at Oliktok to make measurements of clouds in the boundary layer including mixed-phase clouds and to compare measurements with those from the ground and from unmanned aircraft operating in the airspace above AMF3. The ARM facility at Oliktok Point includes Special Use Airspace. A Restricted Area, R-2204, is located at Oliktok Point. Roughly 4 miles in diameter, it facilitates operations of tethered balloons and unmanned aircraft. R-2204 and a new Warning Area north of Oliktok, W-220, are managed by Sandia National Laboratories for DOE Office of Science/BER. These Special Use Airspaces have been successfully used to launch and operate unmanned aircraft over the Arctic Ocean and in international airspace north of Oliktok Point.A steady progression towards routine operations of unmanned aircraft and tethered balloon systems continues at Oliktok. Small unmanned aircraft (DataHawks) and tethered balloons were successfully flown at Oliktok starting in June of 2016. This poster will discuss how principal investigators may apply for use of these Special Use Airspaces, acquire data from the Third ARM Mobile Facility, or bring their own instrumentation for deployment at Oliktok Point, Alaska.
Treatment of Ureterointestinal Anastomotic Strictures by Diathermal or Cryoplastic Dilatation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orsi, Franco; Penco, Silvia; Matei, Victor
2007-09-15
Background. Ureterointestinal anastomotic strictures (UAS) complicate 10-15% of surgeries for urinary diversion and are the main cause of deterioration in renal function. Treatments are surgical revision, management with autostatic stent, balloon dilatation, endoscopic incision, and percutaneous transrenal diathermy (Acucise). A new option is cryoplastic dilatation (Polar-Cath). Purpose. To assess the feasibility, complications, and preliminary results of UAS treatment using the Acucise and Polar-Cath systems. Methods. Nineteen UAS, diagnosed by ultrasonography or computed tomography and sequential renal scintigraphy, occurred in 15 cancer patients after radical cystectomy and urinary diversion. Fifteen were managed with balloon diathermy and 4 by balloon cryoplasty inmore » a three-stage procedure-percutaneous nephrostomy, diathermal or cryoplastic dilatation, and transnephrostomic control with nephrostomy removal-each separated by 15 days. All patients gave written informed consent. Results. Dilatations were successful in all cases. The procedure is simple and rapid (about 45 min) under fluoroscopic control and sedation. Procedural complications occurred in 1 (5%) patient with UAS after Wallace II uretero-ileocutaneostomy: a common iliac artery lesion was induced by diathermal dilatation, evident subsequently, and required surgical repair. Patency with balloon diathermy was good, with two restenoses developing over 12 months (range 1-22) of follow-up. With balloon cryoplastic dilatation, one restenosis developed in the short term; follow-up is too brief to assess the long-term efficacy. Conclusion. Our short-term results with diathermal and cryoplastic dilatation to resolve UAS are good. If supported by longer follow-up, the techniques may be considered as first-choice approaches to UAS. Surgery should be reserved for cases in which this minimally invasive technique fails.« less
Status of the NASA Balloon Program
NASA Technical Reports Server (NTRS)
Needleman, H. C.; Nock, R. S.; Bawcom, D. W.
1993-01-01
The NASA Balloon Program (BP) is examined in an overview of design philosophy, R&D activities, flight testing, and the development of a long-duration balloon for Antarctic use. The Balloon Recovery Program was developed to qualify the use of existing films and to design improved materials and seals. Balloon flights are described for studying the supernova SN1987a, and systems were developed to enhance balloon campaigns including mobile launch vehicles and tracking/data-acquisition systems. The technical approach to long-duration ballooning is reviewed which allows the use of payloads of up to 1350 kg for two to three weeks. The BP is responsible for the development of several candidate polyethylene balloon films as well as design/performance standards for candidate balloons. Specific progress is noted in reliability and in R&D with respect to optimization of structural design, resin blending, and extrusion.
GHOST balloons around Antarctica
NASA Technical Reports Server (NTRS)
Stearns, Charles R.
1988-01-01
The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.
NASA Technical Reports Server (NTRS)
Aber, Gregory S. (Inventor)
1999-01-01
Methods and apparatus are provided for a blood pump bearing system within a pump housing to support long-term high-speed rotation of a rotor with an impeller blade having a plurality of individual magnets disposed thereon to provide a small radial air gap between the magnets and a stator of less than 0.025 inches. The bearing system may be mounted within a flow straightener, diffuser, or other pump element to support the shaft of a pump rotor. The bearing system includes a zirconia shaft having a radiused end. The radiused end has a first radius selected to be about three times greater than the radius of the zirconia shaft. The radiused end of the zirconia shaft engages a flat sapphire endstone. Due to the relative hardness of these materials a flat is quickly produced during break-in on the zirconia radiused end of precisely the size necessary to support thrust loads whereupon wear substantially ceases. Due to the selection of the first radius, the change in shaft end-play during pump break-in is limited to a total desired end-play of less than about 0.010 inches. Radial loads are supported by an olive hole ring jewel that makes near line contact around the circumference of the shaft to support high speed rotation with little friction. The width of olive hole ring jewel is small to allow heat to conduct through to thereby prevent heat build-up in the bearing. A void defined by the bearing elements may fill with blood that then coagulates within the void. The coagulated blood is then conformed to the shape of the bearing surfaces.
NASA Technical Reports Server (NTRS)
Aber, Gregory S. (Inventor)
2000-01-01
An apparatus is provided for a blood pump bearing system within a pump housing to support long-term highspeed rotation of a rotor with an impeller blade having a plurality of individual magnets disposed thereon to provide a small radial air gap between the magnets and a stator of less than 0.025 inches. The bearing system may be mounted within a flow straightener, diffuser, or other pump element to support the shaft of a pump rotor. The bearing system includes a zirconia shaft having a radiused end. The radiused end has a first radius selected to be about three times greater than the radius of the zirconia shaft. The radiused end of the zirconia shaft engages a flat sapphire endstone. Due to the relative hardness of these materials a flat is quickly produced during break-in on the zirconia radiused end of precisely the size necessary to support thrust loads whereupon wear substantially ceases. Due to the selection of the first radius, the change in shaft end-play during pump break-in is limited to a total desired end-play of less than about 0.010 inches. Radial loads are supported by an olive hole ring jewel that makes near line contact around the circumference of the Ir shaft to support big speed rotation with little friction. The width of olive hole ring jewel is small to allow heat to conduct through to thereby prevent heat build-up in the bearing. A void defined by the bearing elements may fill with blood that then coagulates within the void. The coagulated blood is then conformed to the shape of the bearing surfaces.
Concepts for autonomous flight control for a balloon on Mars
NASA Technical Reports Server (NTRS)
Heinsheimer, Thomas F.; Friend, Robyn C.; Siegel, Neil G.
1988-01-01
Balloons operating as airborne rovers have been suggested as ideal candidates for early exploration of the Martian surface. An international study team composed of scientists from the U.S.S.R., France, and the U.S.A. is planning the launching in 1994 of a balloon system to fly on Mars. The current likely design is a dual thermal/gas balloon that consists of a gas balloon suspended above a solar-heated thermal balloon. At night, the thermal balloon provides no lift, and the balloon system drifts just above the Martian surface; the lift of the gas balloon is just sufficient to prevent the science payload from hitting the ground. During the day, the balloon system flies at an altitude of 4 to 5 kilometers, rising due to the added lift provided by the thermal balloon. Over the course of a single Martian day, there may be winds in several directions, and in fact it can be expected that there will be winds simultaneously in different directions at different altitudes. Therefore, a balloon system capable of controlling its own altitude, via an autonomous flight control system, can take advantage of these different winds to control its direction, thereby greatly increasing both its mission utility and its longevity.
Under Pressure: Intraluminal Filling Pressures of Postpartum Hemorrhage Tamponade Balloons
Antony, Kathleen M.; Racusin, Diana A.; Belfort, Michael A.; Dildy, Gary A.
2017-01-01
Objective Uterine tamponade by fluid-filled balloons is now an accepted method of controlling postpartum hemorrhage. Available tamponade balloons vary in design and material, which affects the filling attributes and volume at which they rupture. We aimed to characterize the filling capacity and pressure-volume relationship of various tamponade balloons. Study Design Balloons were filled with water ex vivo. Intraluminal pressure was measured incrementally (every 10 mL for the Foley balloons and every 50 mL for all other balloons). Balloons were filled until they ruptured or until 5,000 mL was reached. Results The Foley balloons had higher intraluminal pressures than the larger-volume balloons. The intraluminal pressure of the Sengstaken-Blakemore tube (gastric balloon) was initially high, but it decreased until shortly before rupture occurred. The Bakri intraluminal pressure steadily increased until rupture occurred at 2,850 mL. The condom catheter, BT-Cath, and ebb all had low intraluminal pressures. Both the BT-Cath and the ebb remained unruptured at 5,000 mL. Conclusion In the setting of acute hemorrhage, expeditious management is critical. Balloons that have a low intraluminal pressure-volume ratio may fill more rapidly, more easily, and to greater volumes. We found that the BT-Cath, the ebb, and the condom catheter all had low intraluminal pressures throughout filling. PMID:28497006
Nácul, Miguel Prestes; Cavazzola, Leandro Totti; Loureiro, Marcelo de Paula; Bonin, Eduardo Aimoré; Ferreira, Paulo Roberto Walter
2015-09-01
To evaluate a new, low-cost, reusable balloon trocar device for dissection of the preperitoneal space during endoscopic surgery. Twenty swine (weight: 15-37 kg) were randomized to two groups, according to whether the preperitoneal space was created with a new balloon device manufactured by Bhio-Supply (group B) or with the commercially available OMSPDB 1000® balloon device manufactured by Covidien (group C). Quality and size of the created preperitoneal space, identification of anatomic structures, balloon dissection time, total procedure time, balloon resistance and internal pressure after insufflation with 300 mL of ambient air, balloon-related complications, and procedure cost were assessed. No significant differences in dissection time, total procedure time, or size of the created preperitoneal space were found between the groups. Balloons in group B had a significantly higher internal pressure compared to balloons in group C. None of the balloons ruptured during the experiment. Three animals in group C had balloon-related peritoneal lacerations. Despite a higher individual device cost, group B had a lower procedure cost over the entire experiment. The new balloon device is not inferior to the commercially available device in terms of the safety and effectiveness for creating a preperitoneal space in swine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saini, Amarjit S.; Zhang, Geoffrey G., E-mail: geoffrey.zhang@moffitt.org; Finkelstein, Steven E.
2011-07-15
Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken withmore » each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.« less
14 CFR 101.7 - Hazardous operations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...
14 CFR 101.7 - Hazardous operations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...
14 CFR 101.7 - Hazardous operations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...
14 CFR 101.7 - Hazardous operations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...
14 CFR 101.7 - Hazardous operations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...
Someya, Takeshi; Kobayashi, Mariko; Waguri, Satoshi; Ushiyama, Tomohiro; Nagaoka, Eiki; Hijikata, Wataru; Shinshi, Tadahiko; Arai, Hirokuni; Takatani, Setsuo
2009-09-01
MedTech Dispo, a disposable maglev centrifugal blood pump with two degrees of freedom magnetic suspension and radial magnetic coupling rotation, has been developed for 1-month extracorporeal circulatory support. As the first stage of a two-stage in vivo evaluation, 2-week evaluation of a prototype MedTech Dispo was conducted. In in vitro study, the pump could produce 5 L/min against 800 mm Hg and the normalized index of hemolysis was 0.0054 +/- 0.0008 g/100 L. In in vivo study, the pump, with its blood-contacting surface coated with biocompatible 2-methacryloyloxyethyl phosphorylcholine polymer, was implanted in seven calves in left heart bypass. Pump performance was stable with a mean flow of 4.49 +/- 0.38 L/min at a mean speed of 2072.1 +/- 64.5 rpm. The maglev control revealed its stability in rotor position during normal activity by the calves. During 2 weeks of operation in two calves which survived the intended study period, no thrombus formation was seen inside the pump and levels of plasma free hemoglobin were maintained below 4 mg/dL. Although further experiments are required, the pump demonstrated the potential for sufficient and reliable performance and biocompatibility in meeting the requirements for cardiopulmonary bypass and 1-week circulatory support.
Code of Federal Regulations, 2013 CFR
2013-01-01
... applicable requirements of this part. (c) For purposes of this part— (1) A captive gas balloon is a balloon that derives its lift from a captive lighter-than-air gas; (2) A hot air balloon is a balloon that... STANDARDS: MANNED FREE BALLOONS General § 31.1 Applicability. (a) This part prescribes airworthiness...
Code of Federal Regulations, 2012 CFR
2012-01-01
... applicable requirements of this part. (c) For purposes of this part— (1) A captive gas balloon is a balloon that derives its lift from a captive lighter-than-air gas; (2) A hot air balloon is a balloon that... STANDARDS: MANNED FREE BALLOONS General § 31.1 Applicability. (a) This part prescribes airworthiness...
Code of Federal Regulations, 2014 CFR
2014-01-01
... applicable requirements of this part. (c) For purposes of this part— (1) A captive gas balloon is a balloon that derives its lift from a captive lighter-than-air gas; (2) A hot air balloon is a balloon that... STANDARDS: MANNED FREE BALLOONS General § 31.1 Applicability. (a) This part prescribes airworthiness...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grena, Roberto
2010-04-15
Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)
NASA balloon design and flight - Philosophy and criteria
NASA Technical Reports Server (NTRS)
Smith, I. S., Jr.
1993-01-01
The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.
Sahin, Tayfun; Karauzum, Kurtulus; Ural, Ertan; Pedersen, Wesley R.
2018-01-01
Percutaneous balloon pulmonary valvuloplasty is the preferred therapy for pulmonary valve stenosis. However, the designs of the cylindrical balloons historically used for valvuloplasty have limitations, especially in patients who have large pulmonary annular diameters. The hourglass-shaped V8 Aortic Valvuloplasty Balloon may prove to be an effective alternative. The balloon has 2 large bulbous segments that are separated by a narrowed waist. The geometric shape is maintained throughout inflation, improving fixation and enabling broader leaflet opening. We present our first experience with the V8 balloon in 3 adults who had severe, symptomatic pulmonary valve stenosis. In addition to describing their cases, we detail our sizing technique for pulmonary valvuloplasty with the V8 balloon. Our successful results suggest that the V8 balloon is efficient and safe for balloon pulmonary valvuloplasty in adults with severe pulmonary valve stenosis. PMID:29844739
Sinha, Santosh Kumar; Mishra, Vikas; Razi, Mahmadula; Jha, Mukesh Jitendra
2017-10-04
Transcatheter therapy of valvular pulmonary stenosis is one of first catheter interventions facilitating its application in field of structural heart disease and now treatment of choice for significant pulmonary stenosis. Myriads of balloon catheter have been used for this purpose starting from Diamond (Boston Scientific,Natick, MA USA), Marshal (Medi-Tech,Watertown MAUSA), Innoue balloon, Tyshak I and currently Tyshak II. Diameter and length of balloon depend on size of annulus and age group, respectively. Problem with shorter balloon is difficulty in keeping it across the annulus while inflation as it tends to slip distally whereas with longer balloon, potential of tricuspid leak or conduction block as it may impinge on adjacent structures. Potential advantage of Accura balloon over Tyshak balloon lies in its peculiar shape while inflation and variable diameter, making stepwise dilatation possible. Here, we report a case of successful balloon pulmonary valvuloplasty using Accura balloon (Vascular Concept, UK) with little modification of conventional technique. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Hirai, Akiko; Hirose, Yoshifumi; Gamoh, Masahiro; Satoh, Minako
2005-10-01
We report successful management of tracheobronchial stent insertion under general anesthesia. In thirty-two cases, tracheobronchial stent insertion was performed under general anesthesia. The technique for airway management was chosen depending on the type of stent or the constriction level of the airway portion. We employed tracheostomy in order to avoid repeated intubations during the insertion of Dumon or Dynamic stent. In case of severe airway stenosis, laser resection or balloon dilatation was performed before stent insertion. We had 32 successful cases in 36 trials. Four trials failed due to insufficient expansion in one, mismatches of stent angle in one and pneumomediastinum in one. There was no exacerbation of respiratory condition in failed cases. There was no case who needed percutaneous cardiopulmonary support system. We managed tracheobronchial stent insertion under general anesthesia. Both the airway expansion by laser resection or balloon dilatation before stent insertion and also the insertion of Dumon or Dynamic stent through a tracheostomy were helpful strategies. These techniques facilitated more definitive airway maintenance and stable anesthetic management.
Comparison of Rectal and Esophageal Sensitivity in Women With Functional Heartburn.
Freede, Margaret; Leasure, A Renee; Proskin, Howard M; Hatch, Daniel; Edwards, Karethy; Pascucci, MaryAnn; Smith, Patsy R
2016-01-01
This study tested the primary hypothesis that there is a correlation of maximum pain threshold (MPT) in the esophagus and rectum in persons with functional heartburn. Secondary aims evaluated correlations with initial perception threshold (IPT) and pain threshold (PT). This study explored objective sensory endpoints of IPT, PT, and MPT in the esophagus and rectum of 14 females with functional heartburn to determine whether visceral hypersensitivity is generalized or organ-specific. Data on volume and pressure measurements at IPT, PT, and MPT with esophageal and rectal barostat distention were collected. The relationship of sensation and pain to volume, pressure, and compliance was analyzed. Esophageal and rectal IPT balloon volume scores were highly and significantly correlated (r = .61, p = .02). Esophageal and rectal PT balloon volume scores were highly and significantly correlated (r = .6, p = .02). Esophageal and rectal MPT balloon volume scores were not correlated (r = .35, p = .26). The correlation of visceral sensitivity in the esophagus and rectum in persons with functional heartburn supports the hypothesis that visceral sensory changes in functional gastrointestinal disorders are not organ specific.
Menon, Anil S; Jourdan, David; Nusbaum, Derek M; Garbino, Alejandro; Buckland, Daniel M; Norton, Sean; Clark, Johnathan B; Antonsen, Erik L
2016-10-01
The StratEx program used a self-contained space suit and balloon system to loft pilot Alan Eustace to a record-breaking altitude and skydive from 135,897 feet (41,422 m). After releasing from the balloon and a stabilized freefall, the pilot safely landed using a parachute system based on a modified tandem parachute rig. A custom spacesuit provided life support using a similar system to NASA's (National Aeronautics and Space Administration; Washington, DC USA) Extravehicular Mobility Unit. It also provided tracking, communications, and connection to the parachute system. A recovery support team, including at least two medical personnel and two spacesuit technicians, was charged with reaching the pilot within five minutes of touchdown to extract him from the suit and provide treatment for any injuries. The team had to track the flight at all times, be prepared to respond in case of premature release, and to operate in any terrain. Crew recovery operations were planned and tailored to anticipate outcomes during this novel event in a systematic fashion, through scenario and risk analysis, in order to minimize the probability and impact of injury. This analysis, detailed here, helped the team configure recovery assets, refine navigation and tracking systems, develop procedures, and conduct training. An extensive period of testing and practice culminated in three manned flights leading to a successful mission and setting the record for exit altitude, distance of fall with stabilizing device, and vertical speed with a stabilizing device. During this mission, recovery teams reached the landing spot within one minute, extracted the pilot, and confirmed that he was not injured. This strategy is presented as an approach to prehospital planning and care for improved safety during crew recovery in novel, extreme events. Menon AS , Jourdan D , Nusbaum DM , Garbino A , Buckland DM , Norton S , Clark JB , Antonsen EL . Crew recovery and contingency planning for a manned stratospheric balloon flight - the StratEx program. Prehosp Disaster Med. 2016;31(5):524-531.
NASA Technical Reports Server (NTRS)
1993-01-01
The observational limitations of earth bound solar studies has prompted a great deal of interest in recent months in being able to gain new scientific perspectives through, what should prove to be, relatively low cost flight of the magnetograph system. The ground work done by TBE for the solar balloon missions (originally planned for SOUP and GRID) as well as the rather advanced state of assembly of the EXVM has allowed the quick formulation of a mission concept for the 30 cm system currently being assembled. The flight system operational configuration will be discussed as it is proposed for short duration flight (on the order of one day) over the continental United States. Balloon hardware design requirements used in formulation of the concept are those set by the National Science Balloon Facility (NSBF), the support agency under NASA contract for flight services. The concept assumes that the flight hardware assembly would come together from three development sources: the scientific investigator package, the integration contractor package, and the NSBF support system. The majority of these three separate packages can be independently developed; however, the computer control interfaces and telemetry links would require extensive preplanning and coordination. A special section of this study deals with definition of a dedicated telemetry link to be provided by the integration contractor for video image data for pointing system performance verification. In this study the approach has been to capitalize to the maximum extent possible on existing hardware and system design. This is the most prudent step that can be taken to reduce eventual program cost for long duration flights. By fielding the existing EXVM as quickly as possible, experience could be gained from several short duration flight tests before it became necessary to commit to major upgrades for long duration flights of this system or of the larger 60 cm version being considered for eventual development.
[Artificial heart--turbo type blood pump for long-term use].
Akamatsu, Teruaki
2003-05-01
Shortage of donor heart for transplantation necessitates long-term artificial assist heart. Turbo-pump is smaller, simpler and cheaper than the pulsatile displacement type pump, but the turbo-pump has defect of thrombus formation at the shaft seal. Our centrifugal pump with magnetically suspended impellers overcomes this defect and is ready for clinical trials now. The structures and functions are described and are compared with the other newly-developed pump of the same kinds with us. And also the pumps of centrifugal type and axial-type, of which impellers are supported by pivots, are reviewed briefly from the stand point for long-term use. Other pumps are referred too: pumps with hydrodynamic bearing and a pump with the shaft seal which is washed and cooled by saline solution.
A new approach for assessing the future of aquifers supporting irrigated agriculture
NASA Astrophysics Data System (ADS)
Butler, James J.; Whittemore, Donald O.; Wilson, Blake B.; Bohling, Geoffrey C.
2016-03-01
Aquifers supporting irrigated agriculture are under stress worldwide as a result of large pumping-induced water deficits. To aid in the formulation of more sustainable management plans for such systems, we have developed a water balance approach for assessing the impact of proposed management actions and the prospects for aquifer sustainability. Application to the High Plains aquifer (HPA) in the state of Kansas in the United States reveals that practically achievable reductions in annual pumping (<22%) would have stabilized areally averaged water levels over much of the Kansas HPA from 1996 to 2013. This demonstrates that modest pumping reductions can have a significant impact and highlights the importance of reliable pumping data for determining the net inflow (capture) component of the water balance. The HPA is similar to many aquifers supporting critically needed agricultural production, so the presented approach should prove of value far beyond the area of this initial application.
Prototype continuous flow ventricular assist device supported on magnetic bearings.
Allaire, P E; Kim, H C; Maslen, E H; Olsen, D B; Bearnson, G B
1996-06-01
This article describes a prototype continuous flow pump (CFVAD2) fully supported in magnetic bearings. The pump performance was measured in a simulated adult human circulation system. The pump delivered 6 L/min of flow at 100 mm Hg of differential pressure head operating at 2,400 rpm in water. The pump is totally supported in 4 magnetic bearings: 2 radial and 2 thrust. Magnetic bearings offer the advantages of no required lubrication and large operating clearances. The geometry and other properties of the bearings are described. Bearing parameters such as load capacity and current gains are discussed. Bearing coil currents were measured during operation in air and water. The rotor was operated in various orientations to determine the actuator current gains. These values were then used to estimate the radial and thrust forces acting on the rotor in both air and water. Much lower levels of force were found than were expected, allowing for a very significant reduction in the size of the next prototype. Hemolysis levels were measured in the prototype pump and found not to indicate damage to the blood cells.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopera, Jorge E., E-mail: Lopera@uthscsa.ed; Alvarez, Alex; Trimmer, Clayton
2009-01-15
The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm{sup 3}, respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containingmore » a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.« less
Retained intraaortic balloon. Case report and review of the literature.
Grande, A M; Martinelli, L; Graffigna, A; Viganò, M
1995-01-01
We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home.
Secco, Gioel Gabrio; Ghione, Matteo; Mattesini, Alessio; Dall'Ara, Gianni; Ghilencea, Liviu; Kilickesmez, Kadriye; De Luca, Giuseppe; Fattori, Rossella; Parisi, Rosario; Marino, Paolo Nicola; Lupi, Alessandro; Foin, Nicolas; Di Mario, Carlo
2016-06-20
Calcific coronary lesions impose a rigid obstacle to optimal balloon and stent expansion and the 20 to 30 atm limit that non-compliant (NC) balloons reach can be insufficient. The aim of our study was to evaluate the safety and efficacy of a new dedicated super high-pressure NC balloon (OPN NC®; SIS Medical AG, Winterthur, Switzerland). We retrospectively evaluated a consecutive series of 91 lesions in which conventional NC balloons at maximal pressure failed to achieve an adequate post-dilatation luminal gain and were therefore treated with an OPN NC balloon up to 40 atm. Angiographic success was defined as residual angiographic diameter stenosis <30%. MLD and %DS were measured at baseline, after NC balloon, OPN NC balloon and stent implantation. Angiographic success was achieved in 84 lesions (92.3%). All of the remaining lesions received rotational atherectomy with the exception of two cases in which rotational atherectomy was not attempted because of small vessel size and excessive tortuosity. MLD and acute gain were significantly greater and %DS was significantly lower post OPN NC balloon compared with conventional NC balloon inflation (p<0.001). No coronary perforations occurred. No acute or 30-day follow-up MACE was reported. When conventional NC balloons fail, the new OPN NC dedicated high-pressure balloon provides an effective and safe alternative strategy for the dilatation of resistant coronary lesions.
Help! My Principal Just Burst My "You Gotta Have Art" Balloon.
ERIC Educational Resources Information Center
Dunn, Phillip C.
1985-01-01
Offers a "marketing strategy" for arts education. Provides statistics from the Americans and the Arts survey, conducted in 1984 by the National Research Center of the Arts, which shows solid public support for the arts both in and out of school. (JDH)
Rees, Paul; Waller, B; Buckley, A M; Doran, C; Bland, S; Scott, T; Matthews, J
2018-05-01
Role 2 Afloat provides a damage control resuscitation and surgery facility in support of maritime, littoral and aviation operations. Resuscitative endovascular balloon occlusion of the aorta (REBOA) offers a rapid, effective solution to exsanguinating haemorrhage from pelvic and non-compressible torso haemorrhage. It should be considered when the patient presents in a peri-arrest state, if surgery is likely to be delayed, or where the single operating table is occupied by another case. This paper will outline the data in support of endovascular haemorrhage control, describe the technique and explore how REBOA could be delivered using equipment currently available in the Royal Navy Role 2 Afloat equipment module. Also discussed are potential future directions in endovascular resuscitation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Stability analysis and trend study of a balloon tethered in a wind, with experimental comparisons
NASA Technical Reports Server (NTRS)
Redd, L. T.; Bland, S. R.; Bennett, R. M.
1973-01-01
A stability analysis and trend study for a balloon tethered in a steady wind are presented. The linearized, stability-derivative type analysis includes balloon aerodynamics, buoyancy, mass (including apparent mass), and static forces resulting from the tether cable. The analysis has been applied to a balloon 7.64 m in length, and the results are compared with those from tow tests of this balloon. This comparison shows that the analysis gives reasonable predictions for the damping, frequencies, modes of motion, and stability boundaries exhibited by the balloon. A trend study for the 7.64-m balloon was made to illustrate how the stability boundaries are affected by changes in individual stability parameters. The trends indicated in this study may also be applicable to many other tethered-balloon systems.
A comparative study of internally and externally capped balloons using small scale test balloons
NASA Technical Reports Server (NTRS)
Bell, Douglas P.
1994-01-01
Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.
Ballooning Then...and Ballooning Now.
ERIC Educational Resources Information Center
Journal of Aerospace Education, 1978
1978-01-01
Describes the history of hot-air balloon travel, starting with its French origins and continuing through to the 1978 national championship. An address for Balloon Federation of America membership is included. (MA)
Single balloon versus double balloon bipedicular kyphoplasty: a systematic review and meta-analysis.
Jing, Zehao; Dong, Jianli; Li, Zhengwei; Nan, Feng
2018-06-19
Kyphoplasty has been widely used to treat vertebral compression fractures (VCFs). In standard procedure of kyphoplasty, two balloons were inserted into the vertebral body through bipedicular and inflated simultaneously, while using a single balloon two times is also a common method in clinic to lessen the financial burden of patients. However, the effect and safety of single balloon versus double balloon bipedicular kyphoplasty are still controversy. In this systematic review and meta-analysis, eligible studies were identified through a comprehensive literature search of PubMed, Cochrane library EMBASE, Web of Science, Wanfang, CNKI, VIP and CBM until January 1, 2018. Results from individual studies were pooled using a random or fixed effects model. Seven articles were included in the systematic review and five studies were consisted in meta-analysis. We observed no significant difference between single balloon and double balloon bipedicular kyphoplasty in visual analog scale (VAS), angle (kyphotic angle and Cobb angle), consumption (operation time, cement volume and volume of bleeding), vertebral height (anterior height, medium height and posterior height) and complications (cement leakage and new VCFs), while the cost of single balloon bipedicular kyphoplasty is lower than that of double balloon bipedicular kyphoplasty. The results of our meta-analysis also demonstrated that single balloon can significantly improve the VAS, angle and vertebral height of patients suffering from VCFs. This systematic review and meta-analysis collectively concludes that single balloon bipedicular kyphoplasty is as effective as double balloon bipedicular kyphoplasty in improving clinical symptoms, deformity and complications of VCFs but not so expensive. These slides can be retrieved under Electronic Supplementary Material.
Kim, Tae Sik; Sun, Kyung; Lee, Kyu Baek; Lee, Hye Won; Baek, Kwang Je; Park, Sung Young; Son, Ho Sung; Kim, Kwang Taik; Kim, Hyoung Mook
2004-12-01
Nonpulsatile blood pumps are mainly used in extracorporeal life support systems. Although pulsating blood flow is known to be physiological, a pulsatile pump is not commonly applied in a circuit with a membrane oxygenator because of damage to the blood cells. The hypothesis that the placement of a pressure-relieving compliance chamber in a circuit might reduce blood cell trauma was tested. An extracorporeal life support circuit was constructed in an acute lung injury model of dogs by oleic acid infusion. The animals were divided into three groups. In group I (n = 6) a nonpulsatile centrifugal pump was used as a control. In group II (n = 4) a single-pulsatile pump was used, and in group III (n = 6) a single-pulsatile pump equipped with a compliance chamber was used. Pump flow was maintained at 1.8-2.0 L/min for 2 h. Hemodynamics and blood gas analyses indicated that the pulsatile groups II and III had better results than the nonpulsatile group I. The plasma-free hemoglobin level, which indicates blood cell trauma, was the lowest in group I and the highest in group II but was significantly decreased in group III. A pressure-relieving compliance chamber could significantly reduce high circuit pressures and blood cell trauma.
Retained intraaortic balloon. Case report and review of the literature.
Grande, A M; Martinelli, L; Graffigna, A; Viganò, M
1995-01-01
We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home. Images PMID:8605436
The French balloon and sounding rocket space program
NASA Astrophysics Data System (ADS)
Coutin/Faye, S.; Sadourny, I.
1987-08-01
Stratospheric and long duration flight balloon programs are outlined. Open stratospheric balloons up to 1 million cu m volume are used to carry astronomy, solar system, aeronomy, stratosphere, biology, space physics, and geophysics experiments. The long duration balloons can carry 50 kg payloads at 20 to 30 km altitude for 10 days to several weeks. Pressurized stratospheric balloons, and infrared hot air balloons are used. They are used to study the dynamics of stratospheric waves and atmospheric water vapor. Laboratories participating in sounding rocket programs are listed.
Pipeline Optimization Program (PLOP)
2006-08-01
the framework of the Dredging Operations Decision Support System (DODSS, https://dodss.wes.army.mil/wiki/0). PLOP compiles industry standards and...efficiency point ( BEP ). In the interest of acceptable wear rate on the pump, industrial standards dictate that the flow Figure 2. Pump class as a function of...percentage of the flow rate corresponding to the BEP . Pump Acceptability Rules. The facts for pump performance, industrial standards and pipeline and
Vacuum pumps and systems: A review of current practice
NASA Technical Reports Server (NTRS)
Giles, Stuart
1986-01-01
A review of the fundamental characteristics of the many types of vacuum pumps and vacuum pumping systems is given. The optimum pumping range, relative cost, performance limitations, maintenance problems, system operating costs and similar subjects are discussed. Experiences from the thin film deposition, chemical processing, material handling, food processing and other industries, as well as space simulation are used to support conclusions and recommendations.
Feasibility of a tiny Gyro centrifugal pump as an implantable ventricular assist device.
Yoshikawa, M; Nakata, K; Ohtsuka, G; Takano, T; Glueck, J; Fujisawa, A; Makinouchi, K; Yokokawa, M; Nosé, Y
1999-08-01
The Gyro pumps were developed for long-term circulatory support. The first generation Gyro pump (C1E3) achieved 1 month paracorporeal circulatory support in chronic animal experiments; the second generation (PI702) implantable ventricular assist device (VAD) was successful for over 6 months. The objective of the next generation Gyro pump is for use as a long-term totally implantable VAD and for pediatric circulatory support. This tiny Gyro pump (KP101) was fabricated with the same design concept as the other Gyro pumps. The possibility of an implantable VAD was determined after performance and hemolysis test results were compared to those of the other Gyro pumps. The pump housing and impeller were fabricated from polycarbonate with an impeller diameter of 35 mm. The diameter and height of the pump housings are 52.3 mm and 29.9 mm, respectively. At this time, a DC brushless motor drives the KP101, which is the same as that for the C1E3. The pump performance was measured in 37% glycerin water at 37 degrees C. Hemolysis tests were performed utilizing a compact mock loop filled with fresh bovine blood in a left ventricular assist device (LVAD) condition at 37 degrees C. The KP101 achieved the LVAD conditions of 5 L/min and 100 mm Hg at 2,900 rpm; generated 10 L/min against 100 mm Hg at 3,200 rpm; 3 L/min against 90 mm Hg at 2,600 rpm; and 2 L/min against 80 mm Hg at 2,400 rpm. In addition, the pump efficiency during this experiment was 12.5%. The other Gyro pumps. that is, the C1E3, PI601, and PI701, in an LVAD condition require 1,600, 2,000, and 2,000 rpm, respectively. The KP101 produced a normalized index of hemolysis (NIH) value of 0.005 g/100 L. With regard to the NIH, the other Gyro pumps, namely the C1E3, PI601, and PI701 demonstrated 0.0007, 0.0028, and 0.004 g/100 L, respectively. The KP101 produced an acceptable pressure flow curve for a VAD. The NIH value was higher than that of other Gyro pumps, but is in an acceptable range.
NASA's Suborbital Center of Excellence - reaching young minds and crafting the future
NASA Astrophysics Data System (ADS)
Cathey, H.; Hottman, S.; Hansen, K.
The NASA Suborbital Center of Excellence is charting new territory. From an idea to promote science and engineering education and outreach, the Suborbital Center of Excellence is working toward the objective of increasing numbers of college graduates choosing a career in suborbital programs. Approaches to excite university students to want to pursue these careers through relevant and useful work experiences will be highlighted. Suborbital platforms include balloons, sounding rockets, research aircraft (manned and remotely piloted vehicles) and small satellites. Key components of this are the Suborbital Center of Excellence co-op program and the support of Engineering ``Capstone'' projects. A number of these projects and programs have been supported during the past year. Highlights of these student hands-on learning experiences will be presented. The projects have included diverse projects ranging from work on a power beaming demonstration and autonomous aircraft control logic to the development of light weight pressure vessels for balloon flights based on ULDB spin-off technology, and balloon drop sonde development. Preparing these future Scientists and Engineers involves the investment of time, energy, and resources. The Suborbital Center of Excellence is uniquely positioned to do this. Future programs and initiatives will be presented. The Suborbital Center of Excellence is evolving, meeting the needs to promote science and engineering education and outreach. Educational outreach initiatives for young children to university students will also be presented. These include hands-on experiments, demonstrations, and suborbital educational materials.
NASA Astrophysics Data System (ADS)
Riedler, W.; Torkar, K.
1996-05-01
This issue is grouped into sections on materials, design, performance and analysis of balloons, reviews of major national and international balloon programmes, novel instrumentation and systems for scientific ballooning, and selected recent scientific observations.
Accurate Determination of the Volume of an Irregular Helium Balloon
ERIC Educational Resources Information Center
Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine
2013-01-01
In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…
Kimura, Sumito; Streiff, Cole; Zhu, Meihua; Shimada, Eriko; Datta, Saurabh; Ashraf, Muhammad; Sahn, David J
2014-02-01
The aim of this study was to assess the accuracy, feasibility, and reproducibility of determining stroke volume from a novel 3-dimensional (3D) color Doppler flow quantification method for mitral valve (MV) inflow and left ventricular outflow tract (LVOT) outflow at different stroke volumes when compared with the actual flow rate in a pumped porcine cardiac model. Thirteen freshly harvested pig hearts were studied in a water tank. We inserted a latex balloon into each left ventricle from the MV annulus to the LVOT, which were passively pumped at different stroke volumes (30-80 mL) using a calibrated piston pump at increments of 10 mL. Four-dimensional flow volumes were obtained without electrocardiographic gating. The digital imaging data were analyzed offline using prototype software. Two hemispheric flow-sampling planes for color Doppler velocity measurements were placed at the MV annulus and LVOT. The software computed the flow volumes at the MV annulus and LVOT within the user-defined volume and cardiac cycle. This novel 3D Doppler flow quantification method detected incremental increases in MV inflow and LVOT outflow in close agreement with pumped stroke volumes (MV inflow, r = 0.96; LVOT outflow, r = 0.96; P < .01). Bland-Altman analysis demonstrated overestimation of both (MV inflow, 5.42 mL; LVOT outflow, 4.46 mL) with 95% of points within 95% limits of agreement. Interobserver variability values showed good agreement for all stroke volumes at both the MV annulus and LVOT. This study has shown that the 3D color Doppler flow quantification method we used is able to compute stroke volumes accurately at the MV annulus and LVOT in the same cardiac cycle without electrocardiographic gating. This method may be valuable for assessment of cardiac output in clinical studies.
Unverzagt, Susanne; Buerke, Michael; de Waha, Antoinette; Haerting, Johannes; Pietzner, Diana; Seyfarth, Melchior; Thiele, Holger; Werdan, Karl; Zeymer, Uwe; Prondzinsky, Roland
2015-03-27
Intra-aortic balloon pump counterpulsation (IABP) is currently the most commonly used mechanical assist device for patients with cardiogenic shock due to acute myocardial infarction. Although there has been only limited evidence from randomised controlled trials, the previous guidelines of the American Heart Association/American College of Cardiology (AHA/ACC) and the European Society of Cardiology (ESC) strongly recommended the use of the IABP in patients with infarction-related cardiogenic shock on the basis of pathophysiological considerations, non-randomised trials and registry data. The recent guidelines downgraded the recommendation based on a meta-analysis which could only include non-randomised trials showing conflicting results. Up to now, there have been no guideline recommendations and no actual meta-analysis including the results of the large randomised multicentre IABP-SHOCK II Trial which showed no survival benefit with IABP support. This systematic review is an update of the review published in 2011. To evaluate, in terms of efficacy and safety, the effect of IABP versus non-IABP or other assist devices guideline compliant standard therapy on mortality and morbidity in patients with acute myocardial infarction complicated by cardiogenic shock. Searches of CENTRAL, MEDLINE (Ovid) and EMBASE (Ovid), LILACS, IndMed and KoreaMed, registers of ongoing trials and proceedings of conferences were updated in October 2013. Reference lists were scanned and experts in the field contacted to obtain further information. No language restrictions were applied. Randomised controlled trials on patients with acute myocardial infarction complicated by cardiogenic shock. Data collection and analysis were performed according to the published protocol. Individual patient data were provided for six trials and merged with aggregate data. Summary statistics for the primary endpoints were hazard ratios (HRs) and odds ratios (ORs) with 95% confidence intervals (CIs). Seven eligible studies were identified from a total of 2314 references. One new study with 600 patients was added to the original review. Four trials compared IABP to standard treatment and three to other percutaneous left assist devices (LVAD). Data from a total of 790 patients with acute myocardial infarction and cardiogenic shock were included in the updated meta-analysis: 406 patients were treated with IABP and 384 patients served as controls; 339 patients were treated without assisting devices and 45 patients with other LVAD. The HR for all-cause 30-day mortality of 0.95 (95% CI 0.76 to 1.19) provided no evidence for a survival benefit. Different non-fatal cardiovascular events were reported in five trials. During hospitalisation, 11 and 4 out of 364 patients from the intervention groups suffered from reinfarction or stroke, respectively. Altogether 5 out of 363 patients from the control group suffered from reinfarction or stroke. Reocclusion was treated with subsequent re-revascularization in 6 out of 352 patients from the intervention group and 13 out of 353 patients of the control group. The high incidence of complications such as moderate and severe bleeding or infection in the control groups has to be attributed to interventions with other LVAD. Possible reasons for bias were more frequent in small studies with high cross-over rates, early stopping and the inclusion of patients with IABP at randomisation. Available evidence suggests that IABP may have a beneficial effect on some haemodynamic parameters. However, this did not result in survival benefits so there is no convincing randomised data to support the use of IABP in infarct-related cardiogenic shock.
"Atmospheric Radiation Measurement (ARM) Research Facility at Oliktok Point Alaska"
NASA Astrophysics Data System (ADS)
Helsel, F.; Ivey, M.; Hardesty, J.; Roesler, E. L.; Dexheimer, D.
2017-12-01
Scientific Infrastructure To Support Atmospheric Science, Aerosol Science and UAS's for The Department Of Energy's Atmospheric Radiation Measurement Programs At The Mobile Facility 3 Located At Oliktok Point, Alaska.The Atmospheric Radiation Measurement (ARM) Program's Mobile Facility 3 (AMF3) located at Oliktok Point, Alaska is a U.S. Department of Energy (DOE) site designed to collect data and help determine the impact that clouds and aerosols have on solar radiation. AMF3 provides a scientific infrastructure to support instruments and collect arctic data for the international arctic research community. The infrastructure at AMF3/Oliktok is designed to be mobile and it may be relocated in the future to support other ARM science missions. AMF3's present base line instruments include: scanning precipitation Radars, cloud Radar, Raman Lidar, Eddy correlation flux systems, Ceilometer, Balloon sounding system, Atmospheric Emitted Radiance Interferometer (AERI), Micro-pulse Lidar (MPL) Along with all the standard metrological measurements. In addition AMF3 provides aerosol measurements with a Mobile Aerosol Observing System (MAOS). Ground support for Unmanned Aerial Systems (UAS) and tethered balloon flights. Data from these instruments and systems are placed in the ARM data archives and are available to the international research community. This poster will discuss what instruments and systems are at the ARM Research Facility at Oliktok Point Alaska.
2014-01-01
Abstract Background: Although increasing numbers of large companies are complying with demands for a breastfeeding-friendly workplace by providing lactation rooms and breast-pumping breaks, the effectiveness for intention to use breast-pumping breaks to express breast milk among employed mothers is uncertain. To explore the impact of employees' perceived breastfeeding support from the workplace and the benefits of breastfeeding on a woman's intention to use breast-pumping breaks after returning to work, we conducted a survey at a female labor-intensive electronics manufacturer in Taiwan. Subjects and Methods: A structured questionnaire survey was administered to 715 working mothers employed in an electronics manufacturing plant in Tainan Science Park in Southern Taiwan. Questionnaire content included female employee demographics, employment characteristics, and breastfeeding behavior after returning to work, as well as employees' perception of breastfeeding-friendly support and awareness of the benefits of breastfeeding when raising their most recently born child. Results: Higher education (odds ratio [OR] 2.33), non–clean room worksite (OR 1.51), awareness of breast-pumping breaks (OR 4.70), encouragement by colleagues to use breast-pumping breaks (OR 1.76), and greater awareness of the benefits of breastfeeding (OR 1.08) were significant predictors of the use of breast-pumping breaks after returning to work, whereas the perception of inefficiency when using breast-pumping breaks reduced an employed mother's intention to use breast-pumping breaks (OR 0.55). Conclusions: This study finds an association between an appreciation of the benefits provided by the employer and the likelihood of increased usage of breastfeeding breaks. Workplaces and employers can help employed mothers to understand the benefits of breastfeeding, which may increase the intention of the mother to take breast-pumping breaks after returning to work. PMID:24304034
2014-06-18
Sara Ann Wylie of Public Lab shows the do to yourself Balloon Mapping Kit, during the first ever White House Maker Faire, which brings together students, entrepreneurs, and everyday citizens who are using new tools and techniques to launch new businesses, learn vital skills in science, technology, engineering, and math (STEM), and fuel the renaissance in American manufacturing, at the White House, Wednesday, June 18, 2014 in Washington. The Balloon Mapping Kit enables you to take your own aerial photos from 1000 ft or higher. The President announced new steps the Administration and its partners are taking to support the ability of more Americans, young and old, to have to access to these tools and techniques and brings their ideas to life. Photo Credit: (NASA/Bill Ingalls)
Experimental Results for Titan Aerobot Thermo-Mechanical Subsystem Development
NASA Technical Reports Server (NTRS)
Pauken, Michael T.; Hall, Jeffery L.
2006-01-01
This paper presents experimental results on a set of 4 thermo-mechanical research tasks aimed at Titan and Venus aerobots: 1. A cryogenic balloon materials development program culminating in the fabrication and testing of a 4.6 m long blimp prototype at 93K. 2. A combined computational and experimental thermal analysis of the effect of radioisotope power system (RPS) waste heat on the behavior of a helium filled blimp hull. 3. Aerial deployment and inflation testing using a blimp 4. A proof of concept experiment with an aerobot-mounted steerable high gain antenna These tasks were supported with JPL internal R&D funds and executed by JPL engineers with substantial industry collaboration for Task #1, the cryogenic balloon materials
Future exploration of Venus (post-Pioneer Venus 1978)
NASA Technical Reports Server (NTRS)
Colin, L.; Evans, L. C.; Greeley, R.; Quaide, W. L.; Schaupp, R. W.; Seiff, A.; Young, R. E.
1976-01-01
A comprehensive study was performed to determine the major scientific unknowns about the planet Venus to be expected in the post-Pioneer Venus 1978 time frame. Based on those results the desirability of future orbiters, atmospheric entry probes, balloons, and landers as vehicles to address the remaining scientific questions were studied. The recommended mission scenario includes a high resolution surface mapping radar orbiter mission for the 1981 launch opportunity, a multiple-lander mission for 1985 and either an atmospheric entry probe or balloon mission in 1988. All the proposed missions can be performed using proposed space shuttle upper stage boosters. Significant amounts of long-lead time supporting research and technology developments are required to be initiated in the near future to permit the recommended launch dates.
Intra-aortic balloon pump in cardiogenic shock: state of the art.
Thomaz, Petronio Generoso; Moura, Leonel Adelino; Muramoto, Giovana; Assad, Renato Samy
2017-01-01
The clinical definition of cardiogenic shock is that of a low cardiac output and evidence of tissue hypoxia in the presence of adequate blood volume. Cardiogenic shock is the main cause of death related to acute myocardial infarction (AMI), with a mortality rate of 45-70% in the absence of aggressive and highly specialized technical care. The intra-aortic balloon pump (IABP) is one of the most widely used mechanical assisting devices. During the last two decades, about 42% of patients with AMI who evolved with cardiogenic shock received mechanical circulatory assistance with IABP. Its clinical indication has been based on non-randomized studies and registry data. Recent studies have shown that the use of IABP did not reduce 30-day mortality in patients with AMI and cardiogenic shock treated with the strategy of early myocardial revascularization as the planned primary objective. The guidelines of the American Heart Association and of the European Society of Cardiology have reassessed their recommendations based on the results of meta-analyzes, including the IABP-SCHOCK II Trial study, which did not evidence an increase in survival of patients who received mechanical support with IABP. This review article addresses the clinical impact of IABP use in the cardiogenic shock caused by AMI. RESUMO A definição clínica de choque cardiogênico é a de um quadro de baixo débito cardíaco e evidência de hipóxia tecidual, na presença de volemia adequada. O choque cardiogênico representa a principal causa de óbito relacionada ao infarto agudo do miocárdio (IAM), com índice de mortalidade em torno de 45% a 70%, na ausência de cuidados técnicos agressivos e altamente especializados. O balão intra-aórtico (BIA) é um dos dispositivos de assistência mecânica mais utilizados no mundo. Nas duas últimas décadas, cerca de 42% dos pacientes com IAM, que evoluíram com choque cardiogênico, receberam assistência circulatória mecânica com BIA. Sua indicação clínica tem sido baseada em estudos não randomizados e dados de registro. Estudos recentes têm demonstrado que o uso do BIA não reduziu a mortalidade hospitalar (30 dias) em pacientes com IAM e choque cardiogênico, tratados com a estratégia de revascularização precoce do miocárdio como objetivo primário planejado. As diretrizes da Associação Americana de Cardiologia e da Sociedade Europeia de Cardiologia reavaliaram suas recomendações, baseadas nos resultados de metanálises, incluindo o estudo IABP-SCHOCK II Trial, que não evidenciou aumento na sobrevida de pacientes que receberam suporte mecânico com BIA. Este artigo de revisão aborda o impacto clínico do uso do BIA no choque cardiogênico ocasionado pelo IAM.
Takami, Y; Makinouchi, K; Otsuka, G; Nosé, Y
1997-12-01
The Gyro C1E3 pump has been developed as a completely sealless centrifugal pump driven by a magnetic coupling system for long-term usage. The Gyro C1E3 pump is a pivot bearing-supported pump in which the impeller is supported with the top and bottom pivot bearings. In the Gyro C1E3 pump, the impeller spinning is affected by the force balance between the floating force (Ff[N]) of the hydrodynamic effect and the magnetic thrust force (Tf[N]). The authors quantitatively investigated the floating force of the impeller in vitro to determine the magnetic coupling distance (MCD[mm]) that would result in stable impeller spinning. In vitro tests were performed using a loop filled with 37% glycerin solution to obtain the relationship between the MCD and floating speed (Rf, rotational speed when the impeller starts floating [rpm]) and the relationship between the MCD and Tf. From the obtained relationships, we calculated Ff and determined the relationship between the Ff and the rotational speed (R). Furthermore, we determined the relationship between d (minimum required MCD [mm]) and R from the results of determining the relationship of the MCD and Tf and of the Ff and R. The following relationships were obtained: Rf = 6.24 x 10(4) x MCD-1.35; Tf = 5.27 x 10(3) x MCD-2.29; Ff = 4.71 x 10(-6) x RPM1.69; and d = 9.02 x RPM-0.85 where RPM is the rotational speed. It was demonstrated that the floating force of the impeller is a function only of the rotational speed in the pivot bearing-supported Gyro C1E3 pump. The floating force is estimated to be 10 N to 40 N at rotational speeds of 1,500 rpm to 3,000 rpm at which the Gyro pump may be used in most clinical situations. It would be possible to control the impeller position of the Gyro pump automatically at the stable spinning condition by controlling the adequate magnetic coupling distance based upon its relationship with the rotational speed which was obtained in this study.
Investigating Diffusion and Entropy with Carbon Dioxide-Filled Balloons
ERIC Educational Resources Information Center
Jadrich, James; Bruxvoort, Crystal
2010-01-01
Fill an ordinary latex balloon with helium gas and you know what to expect. Over the next day or two the volume will decrease noticeably as helium escapes from the balloon. So what happens when a latex balloon is filled with carbon dioxide gas? Surprisingly, carbon dioxide balloons deflate at rates as much as an order of magnitude faster than…
Current trends of balloon laryngoplasty in Thailand.
Moungthong, Greetha; Bunbanjerdsuk, Sacarin; Wright, Nida; Sathavornmanee, Thanakrit; Setabutr, Dhave
2017-06-01
To describe the current trend in balloon laryngoplasty usage and experience by practicing otolaryngologists in Thailand. Anonymous 11 question online and paper survey of otolaryngologists on their current balloon laryngoplasty practices. Current practices and experience in balloon laryngoplasty were queried with multiple choice and open-ended questions. Laser use is the most commonly utilized instrument to treat airway stenosis in Thailand. 86% of respondents do not have experience with balloon dilatation; yet, almost half (47.6%) report they perform a minimum of five airway surgeries per year. Most respondents had been in practice for less than 6 years (41%) and reported that they did not have exposure to balloon use during residency training. The largest barrier reported for the use of balloon instrumentation in the airway is inexperience (44.4%) followed by cost (38.3%), yet most feel that treatment in airway stenosis could benefit by usage of balloons (95.5%). Most otolaryngologists in Thailand do not have experience with the use of balloon dilatation and lack of exposure remains the largest barrier to its use. Otolaryngologists in Thailand feel that increased usage of balloons in the airway could improve airway stenosis treatment in the country.
NASA Astrophysics Data System (ADS)
Yoshida, Tetsuya; Fuke, Hideyuki; Shoji, Yasuhiro; Iijima, Issei; Izutsu, Naoki; Kato, Yoichi; Matsuzaka, Yukihiko; Mizuta, Eiichi; Sato, Takatoshi; Tamura, Keisuke; Saito, Yoshitaka; Kakehashi, Yuya
2012-07-01
Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency conducts domestic balloon campaigns at Taiki Aerospace Research Field (TARF) in Hokkaido since 2008. The ballooning at TARF becomes stable after four year operation. Because the field faces to the Pacific Ocean, heavy balloons and payloads can be launched safely using a very unique sliding launcher. Recoveries at the inshore along the Tokachi coast can be done very quickly and smoothly. Unfortunately, flight opportunities are recently limited due to unfriendly weather condition. Unstable Jet stream also prevents us to have so-called `boomerang flight' to achieve long flight duration more than several hours. Six balloon-borne experiments were carried out in 2010 and 2011. Three of them were demonstrations of challenges of space engineering, two were in-situ atmospheric observation, and one was the technical flight of new high-resolution γ-ray telescope. In addition to these flights, we carried out two launches for next generation balloons: one for Tawara-shaped superpressure balloon and the other for ultra-thin high-altitude balloon. In this paper, recent activities of the Japanese scientific balloon program will be introduced. On-going development of the balloon system will also be presented.
Development of a super-pressure balloon with a diamond-shaped net
NASA Astrophysics Data System (ADS)
Saito, Y.; Iijima, I.; Matsuzaka, Y.; Matsushima, K.; Tanaka, S.; Kajiwara, K.; Shimadu, S.
2014-10-01
The essential reason of the lobed-pumpkin shaped super-pressure balloon to withstand against the high pressure is that the local curvature of the balloon film is kept small. Recently, it has been found that the small local curvature can also be obtained if the balloon is covered by a diamond-shaped net with a vertically elongated shape. The development of the super-pressure balloon using this method was started from a 3-m balloon with a polyethylene film covered by a net using Kevlar ropes. The ground inflation test showed the expected high burst pressure. Then, a 6-m and a 12-m balloon using a polyethylene film and a net using the Vectran were developed and stable deployment was checked through the ground inflation tests. The flight test of a 3000 m3 balloon was performed in 2013 and shown to resist a pressure of at least 400 Pa. In the future, after testing a new design to relax a possible stress concentration around the polar area, test flights of scaled balloons will be performed gradually enlarging their size. The goal is to launch a 300,000 m3 super-pressure balloon.
Hu, Hong-Tao; Shin, Ji Hoon; Kim, Jin-Hyoung; Jang, Jong Keon; Park, Jung-Hoon; Kim, Tae-Hyung; Nam, Deok Ho; Song, Ho-Young
2015-07-01
We aimed to evaluate the safety and clinical effectiveness of fluoroscopically guided large balloon dilatation for treating congenital esophageal stenosis in children. Our study included seven children (mean age 4.0 years) who underwent a total of ten balloon dilatation sessions. The initial balloon diameters were 10-15 mm. The technical success, clinical success (improved food intake and reduced dysphagia within 1 month following the first balloon dilatation), dysphagia recurrence, and complications were retrospectively evaluated. Technical and clinical success rates were 100 %. During the mean 38-month follow-up period after the first balloon dilatation, 3 (43 %) patients underwent only one additional balloon dilatation 4-5 months after the first balloon dilatation for dysphagia recurrence. Two of them showed improvement without further recurrence, while the remaining one underwent partial esophagectomy. Well-contained transmural esophageal rupture (type 2) occurred in two (29 %, 2/7) patients and during two (20 %, 2/10) balloon dilatation sessions. All ruptures were successfully treated conservatively. Our study showed that fluoroscopically guided large balloon dilatation seems to be a simple and effective primary treatment technique for congenital esophageal stenosis in children. Esophageal ruptures were not uncommon although they were not fatal.
Wang, Dongyu; Xu, Shuqia; Qiu, Xiwen; Zhu, Caixia; Li, Zhuyu; Wang, Zilian; Hou, Hongying; Gao, Yu; Wang, Xiaoyi; He, Ping; Qin, Yiwei; Liu, Lihua
2017-12-18
To evaluate the success rate and protocol of the Bakri balloon for postpartum hemorrhage (PPH) in the course of a prospective observational multicenter cohort study in South China. At 20 hospitals in South China, women with postpartum bleeding who failed to respond to the first-line conservative management and received the Bakri balloon were recruited for the study. Maternal characteristics, PPH characteristics, PPH management and outcomes in regard to the Bakri balloon use were recorded. A total of 472 women had a Bakri balloon tamponade and 407 (86.23%) women were enrolled (67 after vaginal delivery and 340 either during or after cesarean delivery). The success rate of the Bakri balloon in this study was 91.65% (373/407 women). During vaginal deliveries, the group with a hemorrhage >2000 mL before balloon insertion had significantly more blood loss (551.67±635.17 mL vs. 242.06±313.69 mL, P=0.039) and lower maternal hemoglobin (73±21.77 g/L vs. 92.06±19.60 g/L, P=0.029) after using Bakri balloon than the group with a hemorrhage <1000 mL. Similar data were found during cesarean deliveries. The blood loss before and after balloon insertion were significantly higher in the Bakri balloon failure group (1700±1429.88 mL before and 1209.58±1139.72 mL after using the balloon) than those in the success group [918±493.92 mL before (P=0.002) and 266.57±361.60 mL after using the balloon (P=0.001)]. Rapid diagnosis or prognosis of PPH, in combination with early usage of the Bakri postpartum balloon is more effective for the management of PPH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoshimatsu, Rika; Yamagami, Takuji, E-mail: yamagami@kochi-u.ac.jp; Ishikawa, Masaki
2016-06-15
PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumormore » enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.« less
Yang, Yu-Long; Zhang, Cheng; Wu, Ping; Ma, Yue-Feng; Li, Jing-Yi; Zhang, Hong-Wei; Shi, Li-Jun; Lin, Mei-Ju; Yu, Ying
2016-05-06
Anastomotic stricture is a complex and substantial complication following Roux-en-Y hepaticojejunostomy. Initially, endoscopic and percutaneous approaches are often attempted, but the gold standard remains surgical biliary reconstruction, especially for refractory stricture. However, this solution leaves much room for improvement, due to the challenging nature of the biliary reconstruction procedure, in which anastomotic stricture may still occur. To investigate the feasibility and effectiveness of choledochoscopic high-frequency needle-knife electrotomy as an intervention in the treatment of anastomotic strictures following Roux-en-Y hepaticojejunostomy. From February 2010 to October 2014, clinical data was collected and retrospectively compared for patients who underwent balloon dilation or/and choledochoscopic high-frequency needle-knife electrotomy for the treatment of anastomotic strictures after Roux-en-Y hepaticojejunostomy. A total of 38 patients underwent successful choledochoscopic treatment and all the anastomotic strictures were removed successfully, 19 of which were treated with electrotomy, 7 with balloon dilation, and 12 with both electrotomy and balloon dilation. Among these groups,the average operating times were 6.9 ± 2.4 min,10.1 ± 6.8 min, and 20.2 ± 13.5 min, respectively. The average stent supporting times were 6.3 ± 0.7 months, 6.5 ± 0.6 months, and 6.1 ± 0.4 respectively. The mean follow-up after stent removal was 42.1 ± 27.4 months, and in 26.3 % (5/19), 28.5 % (2/7) and 16.7 % (2/12) of cases, recurrent anastomotic stricture occurred. Of these 9 total patients with recurrent anastomotic, two patients were successfully rescued by full-covered self-expanding removable metal stents and 7 patients by electrotomy combined with balloon dilation. Choledochoscopic high-frequency needle-knife electrotomy is both feasible and safe in the treatment of anastomotic stricture after Roux-en-Y hepaticojejunostomy, with a similar long-term outcome to balloon dilation in treating anastomotic stricture after Roux-en-Y hepaticojejunostomy. A combination of choledochoscopic electrotomy concurrent with balloon dilation should be recommended based on the low rate of recurrence.
Testing of the Anorectal and Pelvic Floor Area
... minutes and is well tolerated by most people. Balloon capacity and compliance A balloon capacity and compliance ... while measurements of volume and pressure are recorded. Balloon evacuation study A balloon evacuation study tests pelvic ...
Circulatory support for OPCAB procedures.
Mueller, Xavier M; von Segesser, Ludwig K
2002-07-01
During off-pump coronary artery bypass grafting (OPCAB) which allows complete revascularization through a median sternotomy, revascularization of the lateral and posterior walls requires the verticalization of the heart, which may cause haemodynamic disturbance. This concern has stimulated the development of circulatory support with mini-pumps. Initially, these pumps were designed for the right side of the heart, which was found to be the main contributor to haemodynamic instability under experimental conditions. The three types of mini-pumps that have been developed so far - two for the right side of the heart and one for both sides - are reviewed as well as a new concept of integrated cardiopulmonary bypass (CPB) circuit with reduced surface and priming volume. However, with increasing experience and improved methods of exposition, OPCAB has become a procedure that can be performed without support in the majority of the cases. Nevertheless, the concept of miniaturization and the possibility to insert these devices through a peripheral access has opened the way to new indications, mainly short-term circulatory support for acute heart failure. This development is welcome in a field where available devices are invasive and plagued with a heavy morbidity.
Cobb, W.G.
1959-06-01
A reactor fuel pump is described which offers long life, low susceptibility to radiation damage, and gaseous fission product removal. An inert-gas lubricated bearing supports a journal on one end of the drive shsft. The other end has an impeller and expansion chamber which effect pumping and gas- liquid separation. (T.R.H.)
On the response of superpressure balloons to displacements from equilibrium density level
NASA Technical Reports Server (NTRS)
Levanon, N.; Kushnir, Y.
1976-01-01
The response of a superpressure balloon to an initial displacement from its constant-density floating level is examined. An approximate solution is obtained to the governing vertical equation of motion for constant-density superpressure balloons. This solution is used to filter out neutrally buoyant oscillations in balloon records despite the nonlinear behavior of the balloon. The graph depicting the pressure data after deconvolution between the raw pressure data and the normalized balloon wavelet shows clearly the strong filtering-out of the neutral buoyancy oscillations.
Lin, Lian-Yu; Liao, Che-Wei; Wang, Chih-Hsien; Chi, Nai-Hsin; Yu, Hsi-Yu; Chou, Nai-Kuan; Hwang, Juey-Jen; Lin, Jiunn-Lee; Chiang, Fu-Tien; Chen, Yih-Sharng
2016-01-01
Extra-corporeal membranous oxygenation (ECMO) has been applied in patients with cardiopulmonary failure. One critical drawback of peripheral ECMO is an increase in left ventricular (LV) afterload which could be counterbalanced by the combination of intra-aortic balloon counter-pulsation (IABP) therapy. We hypothesized that an add-on therapy with IABP could improve outcomes in patients receiving ECMO support. We included patients (>18 years old) from 2002 to 2013 requiring ECMO support due to cardiogenic shock in a medical center. A total of 529 patients (227 ECMO alone and 302 combined IABP plus ECMO) were included. The mortality rates at 2 weeks (48.5 vs. 47.7%) after ECMO implantation were not different between the two groups (ECMO vs. combined group). After adjustment for propensity score and potential confounders, the odds ratios of outcomes within 14 days (combined group vs. ECMO) for poor LV systolic function, high preload, multi-organ failure and mortality were not different. The results remained similar for subgroup analysis. Compared with ECMO alone, combined IABP and ECMO treatment did not improve outcomes in patients with circulatory failure. PMID:27032984
Performance Characterization of a Three-Axis Hall Effect Thruster
2010-12-01
mounted to the vacuum tank overhead and were individually connected to CVI CBST 6.0 scroll compressor units via flexible tubing. The pumps were capable...and Support Equipment . . . . . . . . . 23 3.2.1 Vacuum Chamber . . . . . . . . . . . . . . . . . 23 3.2.2 Pumps and Pump -down Sequence...Sequence. Chamber pressure monitoring and control of vacuum pumps was accomplished using a combination of two gauge systems. The first was used when tank
Embolization of direct carotid cavernous fistulas with the novel double-balloon technique
Niu, Yin; Li, Lin; Tang, Jun; Zhu, Gang
2015-01-01
Multiple endovascular management of direct carotid cavernous fistula (CCF) has been widely accepted as a treatment option. Embolization of the fistula with detachable balloons or thrombogenic coil-based occlusion has been the main choice to treat direct CCF, with good safety and efficacy. This study investigated the safety and efficacy of embolization of direct CCF with the novel double-balloon technique. A retrospective review of a prospective database on cerebral vascular disease was performed. We identified a total of five patients presenting with high-flow direct CCF. All patients were managed with transarterial embolization with the novel double-balloon technique. Three of the five patients were treated with two detachable balloons, and a completely occluded fistula with preservation of the internal carotid artery was achieved. Of the remaining two patients treated with more detachable balloons, one patient achieved a perfect outcome and the other one suffered from recurrent fistula due to balloon migration 3 weeks after embolization. During a follow-up period of 12–18 months, no symptoms reoccurred in any patient. Thus, the double-balloon treatment may be a promising method for CCF complete occlusion. This novel technique may bring more benefits in the following two cases: 1). A single inflated detachable balloon fails to completely occlude the CCF, which causing the next balloon can not pass into the fistula. 2). A giant CCF needs more balloons for fistula embolization. PMID:26586136
Health monitoring with optical fiber sensors: from human body to civil structures
NASA Astrophysics Data System (ADS)
Pinet, Éric; Hamel, Caroline; Glišić, Branko; Inaudi, Daniele; Miron, Nicolae
2007-04-01
Although structural health monitoring and patient monitoring may benefit from the unique advantages of optical fiber sensors (OFS) such as electromagnetic interferences (EMI) immunity, sensor small size and long term reliability, both applications are facing different realities. This paper presents, with practical examples, several OFS technologies ranging from single-point to distributed sensors used to address the health monitoring challenges in medical and in civil engineering fields. OFS for medical applications are single-point, measuring mainly vital parameters such as pressure or temperature. In the intra-aortic balloon pumping (IABP) therapy, a miniature OFS can monitor in situ aortic blood pressure to trigger catheter balloon inflation/deflation in counter-pulsation with heartbeats. Similar sensors reliably monitor the intracranial pressure (ICP) of critical care patients, even during surgical interventions or examinations under medical resonance imaging (MRI). Temperature OFS are also the ideal monitoring solution for such harsh environments. Most of OFS for structural health monitoring are distributed or have long gage length, although quasi-distributed short gage sensors are also used. Those sensors measure mainly strain/load, temperature, pressure and elongation. SOFO type deformation sensors were used to monitor and secure the Bolshoi Moskvoretskiy Bridge in Moscow. Safety of Plavinu dam built on clay and sand in Latvia was increased by monitoring bitumen joints displacement and temperature changes using SMARTape and Temperature Sensitive Cable read with DiTeSt unit. A similar solution was used for monitoring a pipeline built in an unstable area near Rimini in Italy.
A buoyant tornado-probe concept incorporating an inverted lifting device. [and balloon combination
NASA Technical Reports Server (NTRS)
Grant, F. C.
1973-01-01
Addition of an inverted lifting device to a simple balloon probe is shown to make possible low-altitude entry to tornado cores with easier launch conditions than for the simple balloon probe. Balloon-lifter combinations are particularly suitable for penetration of tornadoes with average to strong circulation, but tornadoes of less than average circulation which are inaccessible to simple balloon probes become accessible. The increased launch radius which is needed for access to tornadoes over a wide range of circulation results in entry times of about 3 minutes. For a simple balloon probe the uninflated balloon must be first dropped on, or near, the track of the tornado from a safe distance. The increase in typical launch radius from about 0.75 kilometer to slightly over 1.0 kilometer with a balloon-lifter combination suggests that a direct air launch may be feasible.
NASA Technical Reports Server (NTRS)
Shibasaki, K.; Iwagami, N.; Ogawa, T.
1985-01-01
As a part of the Japanese activities of MAP in the Antarctica, balloon-borne measurements of the stratospheric NO2 profile were planned and carried out by the JARE 23rd and 24th wintering parties. Few results have been reported so far as the stratospheric NO2 profile at high latitude. There were no reported balloon measurements carried out in the Southern Hemisphere. Profiles are presented for the first balloon-borne measurement of the stratospheric NO2 in the Antarctica. Three balloons named JA21, JA25 and JA26 were launched from Syowa Station (69 deg S, 35.6 deg E) using 5000 cu. cm plastic balloons. JA21 balloon was launched on November 24, 1982, and JA25 and JA26 balloons on November 12 and 20, 1983, respectively.
Petersen, Svea; Kaule, Sebastian; Stein, Florian; Minrath, Ingo; Schmitz, Klaus-Peter; Kragl, Udo; Sternberg, Katrin
2013-10-01
Drug-coated balloons (DCB), which have emerged as therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficiency and safety within a number of clinical studies. In vitro studies elucidating the correlation of coating method and composition with DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this context, we evaluated the applicability of a pipetting, dip-coating, and spray-coating process for the establishment of DCB based on paclitaxel (PTX) and the ionic liquid cetylpyridinium salicylate (Cetpyrsal) as novel innovative additive in three different compositions. Among tested methods and compositions, the pipetting process with 50 wt.% PTX resulted in most promising coatings as drug load was less controllable by the other processes and higher PTX contents led to considerable drug crystallization, as visualized by electron microscopy, accelerating PTX loss during short-term elution. Applying these conditions, homogeneous coatings could be applied on balloon catheter, whose simulated use in an in vitro vessel model revealed percental drug losses of 36 and 28% during transit and percental drug transfers of 12 and 40% under expansion for coatings applied in expanded and folded balloon condition, respectively. In comparison to literature values, these results support the high potential of Cetpyrsal as novel DCB matrix regarding low drug loss and efficient drug transfer. © 2013.
Curtis, Jeptha P.; Rathore, Saif S.; Wang, Yongfei; Chen, Jersey; Nallamothu, Brahmajee K.; Krumholz, Harlan M.
2013-01-01
Background IABPs are frequently used to provide hemodynamic support during high risk percutaneous coronary intervention (PCI), but clinical evidence to support their use is mixed. We examined hospital variation in IABP use among high risk PCI patients, and determined the association of IABP use on mortality in this population. Methods and Results We analyzed data submitted to the CathPCI Registry® between January 2005 and December 2007. High risk PCI was defined as having at least one of the following features: unprotected left main artery as the target vessel, cardiogenic shock, severely depressed left ventricular function, or ST segment elevation myocardial infarction. Hospitals were categorized into quartiles by their proportional use of IABP. We examined differences in in-hospital mortality across hospital quartiles using a hierarchical logistic regression model to adjust for differences in patient and hospital characteristics across hospital quartiles of IABP use. IABPs were used in 18,990 (10.5%) of 181,599 high risk PCIs. Proportional use of IABP varied significantly across hospital quartiles: Q1: 0.0%–6.5%; Q2: 6.6% to 9.2%; Q3: 9.3% to 14.1%; and Q4: 14.2% to 40.0%. In multivariable analysis, after adjustment for differences in patient and hospital characteristics, in-hospital mortality was comparable across quartiles of hospital IABP usage (Q1: Ref; Q2: Odds Ratio (OR) 1.11, 95% CI 0.99–1.24; Q3: OR 1.03, 95% CI 0.92–1.15; Q4: OR 1.06, 95% CI 0.94–1.18). Conclusion IABP use varied significantly across hospitals for high risk PCI. However, this variation in IABP use was not associated with differences in in-hospital mortality. PMID:22147887
Zhou, Xiang; Liu, Dawei; Su, Longxiang; Long, Yun; Du, Wei; Miao, Qi; Li, Fang; Jin, Zhengyu; Zeng, Zhengpei; Luo, Ailun; Huang, Yuguang
2015-01-01
Abstract Cardiac pheochromocytoma is relatively rare. Few reports describe the intraoperative and postoperative progression of patients experiencing a life-threatening pheochromocytoma crisis treated with extracorporeal membrane oxygenation (ECMO). A 35-year-old man was referred to our facility for paroxysmal hypertension with a 10-year history of sweating, headaches, cardiac palpitations, and postexercise dyspnea. The patient initially underwent urine catecholamine measurement and an isotope scan, somatostatin receptor scintigraphy, and 18F-fluorodeoxyglucose positron emission tomography/computer tomography (CT), which indicated a multiple, cardiac pheochromocytoma. Echocardiography, cardiac magnetic resonance imaging (MRI), CT reconstruction, and a coronary CT angiography revealed several lesions at the aortic root and along the cardiac vasculature. Multifocal cardiac pheochromocytoma was diagnosed and pheochromocytoma crisis with severe cyclic blood pressure fluctuation occurred during surgery. Surgical resection of multiple pheochromocytomas in the right medial carotid sheath, mediastinum between the main and pulmonary arteries, and between the abdominal aorta and inferior vena artery was performed. To ensure cardiac perfusion and avoid severe circulatory fluctuation, the cardiac paraganglioma resection was prioritized. After resecting the cardiac pheochromocytoma, a severe pheochromocytoma crisis with rapid cyclic blood pressure fluctuation developed. ECMO and intraaortic balloon pump (IABP) were initiated to stabilize circulation and perfusion. Phenoxybenzamine, norepinephrine, epinephrine, and fluid resuscitation were administered to support cardiovascular function. The magnitude of blood pressure fluctuation steadily decreased with treatment. IABP was discontinued after 3 days, and ECMO was discontinued after 16 days. The patient was discharged 3 months postoperatively. This case indicates that mechanical life support with ECMO is a valuable option for pheochromocytoma-induced cardiac shock and should be considered as an effective therapeutic choice in patients with highly unstable hemodynamic function. PMID:25929929
Bavishi, Chirag; Lemor, Alejandro; Trivedi, Vrinda; Chatterjee, Saurav; Moreno, Pedro; Lasala, John; Aronow, Herbert D; Dawn Abbott, J
2018-04-01
Patients undergoing percutaneous mechanical circulatory support (pMCS)-assisted percutaneous coronary intervention (PCI) represent a high-risk group vulnerable to complications and readmissions. Thirty-day readmissions after pMCS-assisted PCI are common among patients with comorbidities and account for a significant amount of healthcare spending. Patients undergoing PCI and pMCS (Impella, TandemHeart, or intra-aortic balloon pump) for any indication between January 1, 2012, and November 30, 2014, were selected from the Nationwide Readmissions Database. Patients were identified using appropriate ICD-9-CM codes. Clinical risk factors and complications were analyzed for association with 30-day readmission. Our analysis included 29 247 patients, of which 4535 (15.5%) were readmitted within 30 days. On multivariate analysis, age ≥ 65 years, female sex, hypertension, diabetes, chronic lung disease, heart failure, prior implantable cardioverter-defibrillator, liver disease, end-stage renal disease, and length of stay ≥5 days during index hospitalization were independent predictors of 30-day readmission. Cardiac etiologies accounted for ~60% of readmissions, of which systolic or diastolic heart failure (22%), stable coronary artery disease (11.1%), acute coronary syndromes (8.9%), and nonspecific chest pain (4.0%) were the most common causes. In noncardiac causes, sepsis/septic shock (4.6%), hypotension/syncope (3.2%), gastrointestinal bleed (3.1%), and acute kidney injury (2.6%) were among the most common causes of 30-day readmissions. Mean length of stay and cost of readmissions was 4 days and $16 191, respectively. Thirty-day readmissions after pMCS-assisted PCI are common and are predominantly associated with increased burden of comorbidities. Reducing readmissions for common cardiac etiologies could save substantial healthcare costs. © 2018 Wiley Periodicals, Inc.
European Venus Explorer: An in-situ mission to Venus using a balloon platform
NASA Astrophysics Data System (ADS)
Chassefière, E.; Korablev, O.; Imamura, T.; Baines, K. H.; Wilson, C. F.; Titov, D. V.; Aplin, K. L.; Balint, T.; Blamont, J. E.; Cochrane, C. G.; Ferencz, Cs.; Ferri, F.; Gerasimov, M.; Leitner, J. J.; Lopez-Moreno, J.; Marty, B.; Martynov, M.; Pogrebenko, S. V.; Rodin, A.; Whiteway, J. A.; Zasova, L. V.; the EVE Team
2009-07-01
Planetary balloons have a long history already. A small super-pressure balloon was flown in the atmosphere of Venus in the eighties by the Russian-French VEGA mission. For this mission, CNES developed and fully tested a 9 m diameter super-pressure balloon, but finally replaced it by a smaller one due to mass constraints (when it was decided to send Vega to Halley's Comet). Furthermore, several kinds of balloons have been proposed for planetary exploration [Blamont, J., in: Maran, S.P. (Ed.), The Astronomy and Astrophysics Encyclopedia. Cambridge University Press, p. 494, 1991]. A Mars balloon has been studied for the Mars-94 Russian-French mission, which was finally cancelled. Mars and Venus balloons have also been studied and ground tested at JPL, and a low atmosphere Venus balloon is presently under development at JAXA (the Japanese Space Agency). Balloons have been identified as a key element in an ongoing Flagship class mission study at NASA, with an assumed launch date between 2020 and 2025. Recently, it was proposed by a group of scientists, under European leadership, to use a balloon to characterize - by in-situ measurements - the evolution, composition and dynamics of the Venus atmosphere. This balloon is part of a mission called EVE (European Venus Explorer), which has been proposed in response to the ESA AO for the first slice of the Cosmic Vision program by a wide international consortium including Europe, Russia, Japan and USA. The EVE architecture consists of one balloon platform floating at an altitude of 50-60 km, one short lived probe provided by Russia, and an orbiter with a polar orbit to relay data from the balloon and probe, and to perform remote sensing science observations. The balloon type preferred for scientific goals is one, which would oscillate in altitude through the cloud deck. To achieve this flight profile, the balloon envelope would contain a phase change fluid. While this proposal was not selected for the first slice of Cosmic Vision missions, it was ranked first among the remaining concepts within the field of solar system science.
Jagadeesan, Bharathi D; Grigoryan, Mikayel; Hassan, Ameer E; Grande, Andrew W; Tummala, Ramachandra P
2013-12-01
Ethylene vinyl alcohol copolymer (Onyx) is widely used for the embolization of arteriovenous malformations (AVMs) of the brain, head, and neck. Balloon-assisted Onyx embolization may provide additional unique advantages in the treatment of AVMs in comparison with traditional catheter-based techniques. To report our initial experience in performing balloon-assisted AVM embolization for brain and neck AVMs with the use of the new Scepter-C and Scepter-XC coaxial dual-lumen balloon microcatheters. Balloon-assisted transarterial embolization was performed in a series of 7 patients with AVMs (4 with brain AVMs, 1 with a dural arteriovenous fistula, and 2 with neck AVMs) by using Onyx delivered through the lumen of Scepter-C or Scepter XC coaxial balloon microcatheters. Following the initial balloon-catheter navigation into a feeding artery and the subsequent inflation of the balloon, the embolization was performed by using Onyx 18, Onyx 34, or both. A total of 12 embolization sessions were performed via 17 arterial feeders in these 7 patients. In 1 patient, there was an arterial perforation from the inflation of the balloon; in all others, the embolization goals were successfully achieved with no adverse events. The balloon microcatheters showed excellent navigability, and there were no problems with retrieval or with the repeated inflation and deflation of the balloons. A proximal Onyx plug, which is crucial in many AVM embolizations, was not necessary with this technique. Additionally, fluoroscopy and procedural times seemed lower with this technique compared with conventional embolization methods.
Thermal performance modeling of NASA s scientific balloons
NASA Astrophysics Data System (ADS)
Franco, H.; Cathey, H.
The flight performance of a scientific balloon is highly dependant on the interaction between the balloon and its environment. The balloon is a thermal vehicle. Modeling a scientific balloon's thermal performance has proven to be a difficult analytical task. Most previous thermal models have attempted these analyses by using either a bulk thermal model approach, or by simplified representations of the balloon. These approaches to date have provided reasonable, but not very accurate results. Improvements have been made in recent years using thermal analysis tools developed for the thermal modeling of spacecraft and other sophisticated heat transfer problems. These tools, which now allow for accurate modeling of highly transmissive materials, have been applied to the thermal analysis of NASA's scientific balloons. A research effort has been started that utilizes the "Thermal Desktop" addition to AUTO CAD. This paper will discuss the development of thermal models for both conventional and Ultra Long Duration super-pressure balloons. This research effort has focused on incremental analysis stages of development to assess the accuracy of the tool and the required model resolution to produce usable data. The first stage balloon thermal analyses started with simple spherical balloon models with a limited number of nodes, and expanded the number of nodes to determine required model resolution. These models were then modified to include additional details such as load tapes. The second stage analyses looked at natural shaped Zero Pressure balloons. Load tapes were then added to these shapes, again with the goal of determining the required modeling accuracy by varying the number of gores. The third stage, following the same steps as the Zero Pressure balloon efforts, was directed at modeling super-pressure pumpkin shaped balloons. The results were then used to develop analysis guidelines and an approach for modeling balloons for both simple first order estimates and detailed full models. The development of the radiative environment and program input files, the development of the modeling techniques for balloons, and the development of appropriate data output handling techniques for both the raw data and data plots will be discussed. A general guideline to match predicted balloon performance with known flight data will also be presented. One long-term goal of this effort is to develop simplified approaches and techniques to include results in performance codes being developed.
Solar energy collector including a weightless balloon with sun tracking means
Hall, Frederick F.
1978-01-01
A solar energy collector having a weightless balloon, the balloon including a transparent polyvinylfluoride hemisphere reinforced with a mesh of ropes secured to its outside surface, and a laminated reflector hemisphere, the inner layer being clear and aluminized on its outside surface and the outer layer being opaque, the balloon being inflated with lighter-than-air gas. A heat collection probe extends into the balloon along the focus of reflection of the reflective hemisphere for conducting coolant into and out of the balloon. The probe is mounted on apparatus for keeping the probe aligned with the sun's path, the apparatus being founded in the earth for withstanding wind pressure on the balloon. The balloon is lashed to the probe by ropes adhered to the outer surface of the balloon for withstanding wind pressures of 100 miles per hour. Preferably, the coolant is liquid sodium-potassium eutectic alloy which will not normally freeze at night in the temperate zones, and when heated to 4,000.degree. R exerts a pressure of only a few atmospheres.
NASA Technical Reports Server (NTRS)
Nahra, Henry K.; Kraft, Thomas G.; Yee, Glenda F.; Jankovsky, Amy L.; Flynn, Michael
2006-01-01
This paper describes the results of ground testing of a scroll pump with a potential of being a substitute for the current vacuum pump of the Vapor Phase Catalytic Ammonia Reduction (VPCAR). Assessments of the pressure-time, pump-down time, pump power and the pump noise were made for three configurations of the pump the first of which was without the gas ballast, the second with the gas ballast installed but not operating and the third with the gas ballast operating. The tested scroll pump exhibited optimum characteristics given its mass and power requirements. The pump down time required to reach a pressure of 50 Torr ranged from 60 minutes without the ballast to about 120 minutes with the gas ballast operational. The noise emission and the pump power were assessed in this paper as well.
Prototype Continuous Flow Ventricular Assist Device Supported on Magnetic Bearings.
Allaire, P E; Kim, H C; Maslen, E H; Olsen, D B; Bearnson, G B
1996-05-01
This article describes a prototype continuous flow pump (CFVAD2) fully supported in magnetic bearings. The pump performance was measured in a simulated adult human circulation system. The pump delivered 6 L/min of flow at 100 mm Hg of differential pressure head operating at 2,400 rpm in water. The pump is totally supported in 4 magnetic bearings: 2 radial and 2 thrust. Magnetic bearings offer the advantages of no required lubrication and large operating clearances. The geometry and other properties of the bearings are described. Bearing parameters such as load capacity and current gains are discussed. Bearing coil currents were measured during operation in air and water. The rotor was operated in various orientations to determine the actuator current gains. These values were then used to estimate the radial and thrust forces acting on the rotor in both air and water. Much lower levels of force were found than were expected, allowing for a very significant reduction in the size of the next prototype. Hemolysis levels were measured in the prototype pump and found not to indicate damage to the blood cells. © 1996 International Society for Artificial Organs.
Ballooning Comes of Age: Make Your Own Balloon.
ERIC Educational Resources Information Center
Eckford, Jim
1983-01-01
Provides instructions for building a working model of a hot-air balloon, offering suggestions for a successful flight. Indicates that children can be involved in the projects, for example, by filling in colors in the panels of a balloon drawing. (JN)
Flow Past a Descending Balloon
NASA Technical Reports Server (NTRS)
Baginski, Frank
2001-01-01
In this report, we present our findings related to aerodynamic loading of partially inflated balloon shapes. This report will consider aerodynamic loading of partially inflated inextensible natural shape balloons and some relevant problems in potential flow. For the axisymmetric modeling, we modified our Balloon Design Shape Program (BDSP) to handle axisymmetric inextensible ascent shapes with aerodynamic loading. For a few simple examples of two dimensional potential flows, we used the Matlab PDE Toolbox. In addition, we propose a model for aerodynamic loading of strained energy minimizing balloon shapes with lobes. Numerical solutions are presented for partially inflated strained balloon shapes with lobes and no aerodynamic loading.
Poder, Thomas G; Fisette, Jean-François
2016-07-01
To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.
Improved nuclear fuel assembly grid spacer
Marshall, John; Kaplan, Samuel
1977-01-01
An improved fuel assembly grid spacer and method of retaining the basic fuel rod support elements in position within the fuel assembly containment channel. The improvement involves attachment of the grids to the hexagonal channel and of forming the basic fuel rod support element into a grid structure, which provides a design which is insensitive to potential channel distortion (ballooning) at high fluence levels. In addition the improved method eliminates problems associated with component fabrication and assembly.
Corrosion Control of Central Vehicle Wash Facility Pump Components Using Alternative Alloy Coatings
2016-07-01
military installations are es- sential for supporting the readiness of tactical vehicles. Steel wash-rack pumps are vulnerable to accelerated...Management Command (IMCOM). The technical monitors were Daniel J. Dunmire (OUSD(AT&L)), Bernie Rodriguez (IMPW-FM), and Valerie D. Hines (DAIM-ODF...statement Large steel water pumps are used to pump water into the Central Vehicle Wash Facility (CVWF) for vehicle washing at Fort Polk, LA. The interior
Modeling of SBS Phase Conjugation in Multimode Step Index Fibers
2008-03-01
cavity or in an external amplifier. Since pumping is never a perfectly efficient process, some heat will be introduced, and for very high pump powers...modes it supports, and the incident pump power. While theoretical investigations of SBS PCMs have been conducted by a num- ber of authors, the model...predictions about the phase conjugate fidelity that could be expected from a given pump intensity input coupled into a specific fiber. A numerical
NASA Technical Reports Server (NTRS)
Sisk, Gregory A.
1989-01-01
The high-pressure oxidizer turbopump (HPOTP) consists of two centrifugal pumps, on a common shaft, that are directly driven by a hot-gas turbine. Pump shaft axial thrust is balanced in that the double-entry main inducer/impeller is inherently balanced and the thrusts of the preburner pump and turbine are nearly equal but opposite. Residual shaft thrust is controlled by a self-compensating, non-rubbing, balance piston. Shaft hang-up must be avoided if the balance piston is to perform properly. One potential cause of shaft hang-up is contact between the Phase 2 bearing support and axial spring cartridge of the HPOTP main pump housing. The status of the bearing support/axial spring cartridge interface is investigated under current loading conditions. An ANSYS version 4.3, three-dimensional, finite element model was generated on Lockheed's VAX 11/785 computer. A nonlinear thermal analysis was then executed on the Marshall Space Flight Center Engineering Analysis Data System (EADS). These thermal results were then applied along with the interference fit and bolt preloads to the model as load conditions for a static analysis to determine the gap status of the bearing support/axial spring cartridge interface. For possible further analysis of the local regions of HPOTP main pump housing assembly, detailed ANSYS submodels were generated using I-DEAS Geomod and Supertab (Appendix A).
NASA Technical Reports Server (NTRS)
Schunk, R. Gregory
2002-01-01
This paper presents the Modeling and Analysis of the Space Station Environment Control and Life Support System Pressure Control Pump Assembly (PCPA). The contents include: 1) Integrated PCPA/Manifold Analyses; 2) Manifold Performance Analysis; 3) PCPA Motor Heat Leak Study; and 4) Future Plans. This paper is presented in viewgraph form.
Hot-air balloon tours: crash epidemiology in the United States, 2000-2011.
Ballard, Sarah-Blythe; Beaty, Leland P; Baker, Susan P
2013-11-01
Hot-air balloon tours are FAR Part 91-governed balloon rides conducted for compensation or hire. Part 91, General Aviation, in general involves the least strict federal regulations and accounts for the majority of aviation crashes and fatalities. National Transportation Safety Board reports of hot-air balloon tour crashes in the United States from 2000 through 2011 were read and analyzed. During the 12-yr period, 78 hot-air balloon tours crashed, involving 518 occupants. There were 91 serious injuries and 5 fatalities; 83% of crashes resulted in one or more serious or fatal outcomes. Of the serious injuries characterized, 56% were lower extremity fractures. Most crashes (81%) occurred during landing; 65% involved hard landings. Fixed object collisions contributed to 50% of serious injuries and all 5 fatalities. During landing sequences, gondola dragging, tipping, bouncing, and occupant ejection were associated with poor outcomes. Of the crashes resulting in serious or fatal outcomes, 20% of balloons were significantly damaged or destroyed. The incidence of morbidity and mortality is high among hot-air balloon tour crashes, and the proportion of balloon crashes attributed to paid rides appears to have increased over time. In addition to examining the role of restraint systems, personal protective equipment, and power line emergency procedures in ballooning, injury prevention efforts should target factors such hard landings, object strikes, gondola instability, and occupant ejections, which are associated with balloon injuries and deaths. Crash outcomes may also improve with vehicle engineering that enables balloons themselves to absorb impact forces.
... with a balloon catheter and expands when the balloon is inflated. The stent is then left there to help keep the artery open. ... with a balloon catheter and expands when the balloon is inflated. The stent is then left there to help keep the artery open.