Sample records for balloon-assisted coil embolization

  1. Symptomatic delayed coil migration after balloon assisted embolization: An underreported adverse event?

    PubMed

    Fonseca, Lino; Najarro-Quispe, Rafael; Rodríguez-Hernández, Ana; Torné, Ramon; Gándara-Sabatini, Dario; Arikan, Fuat; Baños-Carrasco, Pilar

    2018-04-03

    Microsurgical clipping is still regarded as the gold-standard treatment for broad-neck intracranial aneurysms. New endovascular techniques like balloon or stent assisted coiling are quickly rising to the challenge and showing promising outcomes. As a result, broad-neck aneurysms are increasingly addressed by these techniques despite they have not been tested against clipping in a randomized controlled trial and long-term complications might be unknown yet. Intraprocedural coil migration has been well documented in the literature, but the same complication in a delayed fashion is scarcely reported. We present a case of delayed coil migration occurring after a balloon-assisted embolization of a wide-necked intracranial aneurysm and we perform a literature review for similar cases. We discuss how, despite seeming an extremely rare complication, with new endovascular techniques increasingly perceived as the safer option in any aneurysm, potential adverse events may become more frequent. Strategies proposed to address this developing scenario are also reviewed. Copyright © 2018 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Balloon-Assisted Coil Embolization for Large-Necked Renal Artery Aneurysms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mounayer, Charbel; Aymard, Armand; Saint-Maurice, Jean-Pierre

    2000-03-15

    An aneurysm of the right renal artery was discovered in a patient suffering from cerebral arterial angiodysplasia and arterial hypertension. The aneurysm was large necked, which made selective endovascular treatment very difficult. To perform the embolization of the aneurysm, a balloon remodelling technique was used. This prevented migration of coils within the arterial lumen.

  3. Balloon-assisted embolization of skull base meningioma with liquid embolic agent.

    PubMed

    Abdel Kerim, Amr; Bonneville, Fabrice; Jean, Betty; Cornu, Philippe; LeJean, Lise; Chiras, Jacques

    2010-01-01

    The authors report a novel technique of balloon-assisted embolization of a skull base meningioma supplied by a branch of the cavernous segment of the internal carotid artery using liquid embolic agent. A temporarily inflated balloon distal to the meningioma's feeding vessel may improve the access to this small branch and may reduce the chances of unintended reflux during delivery of the liquid embolic agent.

  4. Endovascular balloon-assisted embolization of intracranial and cervical arteriovenous malformations using dual-lumen coaxial balloon microcatheters and Onyx: initial experience.

    PubMed

    Jagadeesan, Bharathi D; Grigoryan, Mikayel; Hassan, Ameer E; Grande, Andrew W; Tummala, Ramachandra P

    2013-12-01

    Ethylene vinyl alcohol copolymer (Onyx) is widely used for the embolization of arteriovenous malformations (AVMs) of the brain, head, and neck. Balloon-assisted Onyx embolization may provide additional unique advantages in the treatment of AVMs in comparison with traditional catheter-based techniques. To report our initial experience in performing balloon-assisted AVM embolization for brain and neck AVMs with the use of the new Scepter-C and Scepter-XC coaxial dual-lumen balloon microcatheters. Balloon-assisted transarterial embolization was performed in a series of 7 patients with AVMs (4 with brain AVMs, 1 with a dural arteriovenous fistula, and 2 with neck AVMs) by using Onyx delivered through the lumen of Scepter-C or Scepter XC coaxial balloon microcatheters. Following the initial balloon-catheter navigation into a feeding artery and the subsequent inflation of the balloon, the embolization was performed by using Onyx 18, Onyx 34, or both. A total of 12 embolization sessions were performed via 17 arterial feeders in these 7 patients. In 1 patient, there was an arterial perforation from the inflation of the balloon; in all others, the embolization goals were successfully achieved with no adverse events. The balloon microcatheters showed excellent navigability, and there were no problems with retrieval or with the repeated inflation and deflation of the balloons. A proximal Onyx plug, which is crucial in many AVM embolizations, was not necessary with this technique. Additionally, fluoroscopy and procedural times seemed lower with this technique compared with conventional embolization methods.

  5. Balloon-augmented Onyx endovascular ligation: initial human experience and comparison with coil ligation.

    PubMed

    Osanai, Toshiya; Bain, Mark D; Toth, Gabor; Hussain, M Shazam; Hui, Ferdinand K

    2015-08-01

    Carotid artery sacrifice remains an important procedure for cerebral vascular disorders despite the development of new endovascular devices. Conventional carotid artery sacrifice with detachable coils alone often requires numerous coils to complete occlusion. To describe the initial human experience with balloon-augmented Onyx and coil vessel sacrifice based on our previous experience with animals. We performed a retrospective review of patients who underwent carotid artery sacrifice between 2008 and 2012 in accordance with local investigational review board approval. Two methods were used to occlude carotid arteries-namely, combined Onyx and coil embolization and traditional coil embolization. We compared the two methods for the cost of embolizate, time to occlude the vessels, and the number of coils. Eight consecutive patients (combined group n=3, traditional group n=5) were assessed. The median cost of embolic material was $6321 in the combined Onyx and coil embolization group and $29 996 in the traditional coil embolization group. The median time from first coil placement to achievement of vessel occlusion was 52 min in the Onyx group and 113 min in the coil embolization group. The median number of coils used was 4 in the Onyx group and 35 in the coil embolization group (p<0.05). No symptomatic complications or recurrences were seen in the combined group. Balloon-augmented Onyx endovascular ligation may reduce costs and fluoroscopy times during vessel sacrifice. Further studies in a larger number of patients are needed to confirm these findings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Endovascular balloon-assisted embolization of high-flow peripheral vascular lesions using dual-lumen coaxial balloon microcatheter and Onyx: initial experience.

    PubMed

    Jagadeesan, Bharathi D; Mortazavi, Shabnam; Hunter, David W; Duran-Castro, Olga L; Snyder, Gregory B; Siedel, Glen F; Golzarian, Jafar

    2014-04-01

    Balloon-assisted embolization performed by delivering Onyx ethylene vinyl alcohol copolymer through a dual-lumen coaxial balloon microcatheter is a new technique for the management of peripheral vascular lesions. This technique does not require an initial reflux of Onyx to form around the tip of the microcatheter before antegrade flow of Onyx can commence. In a series of four patients who were treated with the use of this technique, the absence of significant reflux of Onyx was noted, as were excellent navigability and easy retrieval of the balloon microcatheter. However, in one patient, there was inadvertent adverse embolization of a digital artery, which was not caused by reflux of Onyx but could still be related to balloon inflation. © 2013 SIR Published by SIR All rights reserved.

  7. Coil Embolization for Intracranial Aneurysms

    PubMed Central

    2006-01-01

    Executive Summary Objective To determine the effectiveness and cost-effectiveness of coil embolization compared with surgical clipping to treat intracranial aneurysms. The Technology Endovascular coil embolization is a percutaneous approach to treat an intracranial aneurysm from within the blood vessel without the need of a craniotomy. In this procedure, a microcatheter is inserted into the femoral artery near the groin and navigated to the site of the aneurysm. Small helical platinum coils are deployed through the microcatheter to fill the aneurysm, and prevent it from further expansion and rupture. Health Canada has approved numerous types of coils and coil delivery systems to treat intracranial aneurysms. The most favoured are controlled detachable coils. Coil embolization may be used with other adjunct endovascular devices such as stents and balloons. Background Intracranial Aneurysms Intracranial aneurysms are the dilation or ballooning of part of a blood vessel in the brain. Intracranial aneurysms range in size from small (<12 mm in diameter) to large (12–25 mm), and to giant (>25 mm). There are 3 main types of aneurysms. Fusiform aneurysms involve the entire circumference of the artery; saccular aneurysms have outpouchings; and dissecting aneurysms have tears in the arterial wall. Berry aneurysms are saccular aneurysms with well-defined necks. Intracranial aneurysms may occur in any blood vessel of the brain; however, they are most commonly found at the branch points of large arteries that form the circle of Willis at the base of the brain. In 85% to 95% of patients, they are found in the anterior circulation. Aneurysms in the posterior circulation are less frequent, and are more difficult to treat surgically due to inaccessibility. Most intracranial aneurysms are small and asymptomatic. Large aneurysms may have a mass effect, causing compression on the brain and cranial nerves and neurological deficits. When an intracranial aneurysm ruptures and bleeds

  8. Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.

    PubMed

    Liu, Jian; Jing, Linkai; Wang, Chao; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-11-01

    Endovascular treatment of paraclinoid aneurysms is preferred in clinical practice. Flow alterations caused by stents and coils may affect treatment outcome. To assess hemodynamic changes following stent-assisted coil embolization (SACE) in subtotally embolized paraclinoid aneurysms with residual necks that were predisposed to recanalization. We studied 27 paraclinoid aneurysms (seven recanalized and 20 stable) treated with coils and Enterprise stents. Computational fluid dynamic simulations were performed on patient-specific aneurysm geometries using virtual stenting and porous media technology. After stent placement in 27 cases, aneurysm flow velocity decreased significantly, the reduction gradually increasing from the neck plane (11.9%), to the residual neck (12.3%), to the aneurysm dome (16.3%). Subsequent coil embolization was performed after stent placement and the hemodynamic factors decreased further and significantly at all aneurysm regions except the neck plane. In a comparison of recanalized and stable cases, univariate analysis showed no significant differences in any parameter before treatment. After stent-assisted coiling, only the reduction in area-averaged velocity at the neck plane differed significantly between recanalized (8.1%) and stable cases (20.5%) (p=0.016). Aneurysm flow velocity can be significantly decreased by stent placement and coil embolization. However, hemodynamics at the aneurysm neck plane is less sensitive to coils. Significant reduction in flow velocity at the neck plane may be an important factor in preventing recanalization of paraclinoid aneurysms after subtotal SACE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Transarterial Balloon-assisted Onyx Embolization of Intracranial Arteriovenous Malformations Using a Dual-lumen Balloon Microcatheter: Two Case Reports.

    PubMed

    Kim, Sang Heum; Kim, Tae Gon; Kong, Min Ho

    2017-09-01

    The Onyx system has been well established in recent years as a very important material in the treatment of arteriovenous malformations (AVMs). When using the Onyx, it is essential to wait for the creation of a plug around the tip of the catheter, which enables the effective forward penetration of Onyx. Recent reports have shown that the introduction of a dimethyl sulfoxide compatible dual-lumen balloon microcatheter improves the efficiency of AVM embolization. We report our recent experience of two cases of intracranial AVM embolization using Onyx and the transarterial balloon-assisted technique. In both cases, the procedures were successfully performed and the nidus of the AVM was totally occluded in a relatively short time. This technique may enable immediate forward flow and penetration of Onyx without concern about reflux. It may also reduce the procedure time and increase the angiographic occlusion rate. Navigation of the dual-lumen balloon microcatheter nevertheless remains a challenge.

  10. Transarterial Balloon-assisted Onyx Embolization of Intracranial Arteriovenous Malformations Using a Dual-lumen Balloon Microcatheter: Two Case Reports

    PubMed Central

    Kim, Sang Heum; Kong, Min Ho

    2017-01-01

    The Onyx system has been well established in recent years as a very important material in the treatment of arteriovenous malformations (AVMs). When using the Onyx, it is essential to wait for the creation of a plug around the tip of the catheter, which enables the effective forward penetration of Onyx. Recent reports have shown that the introduction of a dimethyl sulfoxide compatible dual-lumen balloon microcatheter improves the efficiency of AVM embolization. We report our recent experience of two cases of intracranial AVM embolization using Onyx and the transarterial balloon-assisted technique. In both cases, the procedures were successfully performed and the nidus of the AVM was totally occluded in a relatively short time. This technique may enable immediate forward flow and penetration of Onyx without concern about reflux. It may also reduce the procedure time and increase the angiographic occlusion rate. Navigation of the dual-lumen balloon microcatheter nevertheless remains a challenge. PMID:29159158

  11. Stent-Assisted Coil Embolization of a Traumatic Wide-Necked Renal Segmental Artery Pseudoaneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlunz-Hendann, Martin; Wetter, Axel, E-mail: axel.wetter@klinikum-duisburg.de; Landwehr, Peter

    We present the case of an Afghan woman with a renal segmental artery false aneurysm of the right kidney due to a shell splinter injury. Stent-assisted coil embolization of the aneurysm is described in detail.

  12. Embolization of direct carotid cavernous fistulas with the novel double-balloon technique

    PubMed Central

    Niu, Yin; Li, Lin; Tang, Jun; Zhu, Gang

    2015-01-01

    Multiple endovascular management of direct carotid cavernous fistula (CCF) has been widely accepted as a treatment option. Embolization of the fistula with detachable balloons or thrombogenic coil-based occlusion has been the main choice to treat direct CCF, with good safety and efficacy. This study investigated the safety and efficacy of embolization of direct CCF with the novel double-balloon technique. A retrospective review of a prospective database on cerebral vascular disease was performed. We identified a total of five patients presenting with high-flow direct CCF. All patients were managed with transarterial embolization with the novel double-balloon technique. Three of the five patients were treated with two detachable balloons, and a completely occluded fistula with preservation of the internal carotid artery was achieved. Of the remaining two patients treated with more detachable balloons, one patient achieved a perfect outcome and the other one suffered from recurrent fistula due to balloon migration 3 weeks after embolization. During a follow-up period of 12–18 months, no symptoms reoccurred in any patient. Thus, the double-balloon treatment may be a promising method for CCF complete occlusion. This novel technique may bring more benefits in the following two cases: 1). A single inflated detachable balloon fails to completely occlude the CCF, which causing the next balloon can not pass into the fistula. 2). A giant CCF needs more balloons for fistula embolization. PMID:26586136

  13. Stent-Assisted Coil Embolization of Vertebrobasilar Dissecting Aneurysms: Procedural Outcomes and Factors for Recanalization.

    PubMed

    Jeon, Jin Pyeong; Cho, Young Dae; Rhim, Jong Kook; Park, Jeong Jin; Cho, Won-Sang; Kang, Hyun-Seung; Kim, Jeong Eun; Hwang, Gyojun; Kwon, O-Ki; Han, Moon Hee

    2016-01-01

    Outcomes of stent-assisted coil embolization (SACE) have not been well established in the setting of vertebrobasilar dissecting aneurysms (VBDAs) due to the low percentage of cases that need treatment and the array of available therapeutic options. Herein, we presented clinical and radiographic results of SACE in patients with VBDAs. A total of 47 patients (M:F, 30:17; mean age ± SD, 53.7 ± 12.6 years), with a VBDA who underwent SACE between 2008 and 2014 at two institutions were evaluated retrospectively. Medical records and radiologic data were analyzed to assess the outcome of SACE procedures. Cox proportional hazards regression analysis was conducted to determine the factors that were associated with aneurysmal recanalization after SACE. Stent-assisted coil embolization technically succeeded in all patients. Three cerebellar infarctions occurred on postembolization day 1, week 2, and month 2, but no other procedure-related complications developed. Immediately following SACE, 25 aneurysms (53.2%) showed no contrast filling into the aneurysmal sac. During a mean follow-up of 20.2 months, 37 lesions (78.7%) appeared completely occluded, whereas 10 lesions showed recanalization, 5 of which required additional embolization. Overall recanalization rate was 12.64% per lesion-year, and mean postoperative time to recanalization was 18 months (range, 3-36 months). In multivariable analysis, major branch involvement (hazard ratio [HR]: 7.28; p = 0.013) and the presence of residual sac filling (HR: 8.49, p = 0.044) were identified as statistically significant independent predictors of recanalization. No bleeding was encountered in follow-up monitoring. Stent-assisted coil embolization appears feasible and safe for treatment of VBDAs. Long-term results were acceptable in a majority of patients studied, despite a relatively high rate of incomplete occlusion immediately after SACE. Major branch involvement and coiled aneurysms with residual sac filling may predispose to

  14. A novel balloon assisted two-stents telescoping technique for repositioning an embolized stent in the pulmonary conduit.

    PubMed

    Kobayashi, Daisuke; Gowda, Srinath T; Forbes, Thomas J

    2014-08-01

    A 9-year-old male, with history of pulmonary atresia and ventricular septal defect, status post complete repair with a 16 mm pulmonary homograft in the right ventricular outflow tract (RVOT) underwent 3110 Palmaz stent placement for conduit stenosis. Following deployment the stent embolized proximally into the right ventricle (RV). We undertook the choice of repositioning the embolized stent into the conduit with a transcatheter approach. Using a second venous access, the embolized stent was carefully maneuvered into the proximal part of conduit with an inflated Tyshak balloon catheter. A second Palmaz 4010 stent was deployed in the distal conduit telescoping through the embolized stent. The Tyshak balloon catheter was kept inflated in the RV to stabilize the embolized stent in the proximal conduit until it was successfully latched up against the conduit with the deployment of the overlapping second stent. One year later, he underwent Melody valve implantation in the pre-stented conduit relieving conduit insufficiency. This novel balloon assisted two-stents telescoping technique is a feasible transcatheter option to secure an embolized stent from the RV to the RVOT. © 2014 Wiley Periodicals, Inc.

  15. An Onyx tunnel: reconstructive transvenous balloon-assisted Onyx embolization for dural arteriovenous fistula of the transverse-sigmoid sinus.

    PubMed

    Kerolus, Mena G; Chung, Joonho; Munich, Stephen A; Matsuda, Yoshikazu; Okada, Hideo; Lopes, Demetrius K

    2017-11-17

    Transvenous embolization is an effective method for treating dural arteriovenous fistulas (DAVFs) of the transverse-sigmoid sinus (TSS). However, in cases of complicated DAVFs, it is difficult to preserve the patency of the dural sinus. The authors describe the technical details of a new reconstructive technique using transvenous balloon-assisted Onyx embolization as another treatment option in a patient with an extensive and complex DAVF of the left TSS. A microcatheter and compliant balloon catheter were navigated into the left internal jugular vein and placed at the distal end of the DAVF in the transverse sinus. The microcatheter was placed between the vessel wall of the TSS and the balloon. After the balloon was fully inflated, Onyx-18 was injected at the periphery of the balloon in a slow, controlled, progressive, stepwise manner; the balloon and microcatheter were simultaneously withdrawn toward the sigmoid sinus, with Onyx encompassing the entirety of the complex DAVF. The Onyx refluxed into multiple arterial feeders in a distal-to-proximal step-by-step manner, ultimately resulting in an Onyx tunnel. The final angiography study revealed complete obliteration of the DAVF and patency of the TSS. The Onyx tunnel, or reconstructive transvenous balloon-assisted Onyx embolization technique, may be an effective treatment option for large, complex DAVFs of the TSS. This technique may provide another option to facilitate the complete obliteration of the DAVF while preserving the functional sinus.

  16. Stent-assisted coil embolization of intracranial aneurysms: a single center experience.

    PubMed

    Luo, Chao-Bao; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo; Chang, Cheng-Yen

    2012-07-01

    Endovascular detachable coil embolization has become an important method in the management of intracranial aneurysms. However, coil embolization alone may fail to treat some wide-neck aneurysms. Herein, we report our experience with and outcome of stent-assisted coil embolization (SACE) of intracranial aneurysms. Over a 5-year period, a total of 59 patients diagnosed with 63 intracranial aneurysms underwent SACE. Of the total 63 aneurysms, 6 aneurysms were treated by SACE as a salvageable procedure because of coil instability after detachment. There were 17 men and 42 women enrolled in the study, with ages ranging from 24 to 86 years (mean: 60 years). We retrospectively assessed the clinical data, aneurysm characteristics, and angiographic and clinical outcomes of all patient cases. The mean aneurysm size was 9.4 mm, and the mean neck size was 5.5 mm. Clinical and angiographic follow-up exceeding 6 months were available in 51 and 40 patients, respectively. The mean clinical follow-up time was 28 months (range: 6-49 months). Successful stent deployment was found in 60 aneurysms (95%). Midterm total or subtotal angiographic aneurismal occlusion was obtained in 56 aneurysms (89%), with further thrombosis of the aneurismal sac occurring in 4 (10%). Stable coiling aneurysm was found in 24 (78%), aneurysm recurrence was observed in 5 (13%), and permanent procedural morbidity was observed in two patients (3.4%). During the follow-up period, there were no hemorrhagic events and no stent displacement. Despite a modest procedural complication rate, and some evidence of aneurismal recurrence, SACE was proved to be both effective and safe in managing wide-neck intracranial aneurysms. Our results also demonstrated the midterm durability and stability of aneurysm treated by SACE. Furthermore, SACE can be a salvageable procedure in cases with coil instability after detachment. Copyright © 2012. Published by Elsevier B.V.

  17. Retreatment of recanalized aneurysms after Y-stent-assisted coil embolization with double enterprise stents: case report and systematic review of the literature.

    PubMed

    Kono, Kenichi; Shintani, Aki; Terada, Tomoaki

    2014-01-01

    It is necessary to consider possibility of recanalization and retreatment after coil embolization for cerebral aneurysms. There is concern that retreatment for recanalized aneurysms after Y-stent-assisted coil embolization may be difficult because of double stents, especially in Y-stents with double closed-cell stents owing to narrowed structures. However, no detailed reports of retreatment after Y-stent have been reported. Between July 2010 and June 2013, we treated four aneurysms with Y-stent-assisted coil embolization using Enterprise closed-cell stents. Recanalization occurred in one case (25%), and retreatment was performed. We easily navigated a microcatheter into the target portions of the aneurysm through the Y-stent and occluded the aneurysm with coils. Additionally, by systematically searching in PubMed, we found 105 cases of Y-stent-assisted coil embolization using Enterprise stents or Neuroform stents with more than 6 months of follow-up. Among them, retreatment was performed in 10 cases (9.5%). There were no significant differences in retreatment rates among different stent combinations (P=0.91; Fisher's exact test). In conclusion, navigation of a microcatheter into the aneurysm through the Y-stent with double Enterprise stents was feasible, and retreatment rates after Y-stent-assisted coiling may not depend on stent combinations.

  18. Stent-Assisted Coil Embolization of Vertebrobasilar Dissecting Aneurysms: Procedural Outcomes and Factors for Recanalization

    PubMed Central

    Jeon, Jin Pyeong; Rhim, Jong Kook; Park, Jeong Jin; Cho, Won-Sang; Kang, Hyun-Seung; Kim, Jeong Eun; Hwang, Gyojun; Kwon, O-Ki; Han, Moon Hee

    2016-01-01

    Objective Outcomes of stent-assisted coil embolization (SACE) have not been well established in the setting of vertebrobasilar dissecting aneurysms (VBDAs) due to the low percentage of cases that need treatment and the array of available therapeutic options. Herein, we presented clinical and radiographic results of SACE in patients with VBDAs. Materials and Methods A total of 47 patients (M:F, 30:17; mean age ± SD, 53.7 ± 12.6 years), with a VBDA who underwent SACE between 2008 and 2014 at two institutions were evaluated retrospectively. Medical records and radiologic data were analyzed to assess the outcome of SACE procedures. Cox proportional hazards regression analysis was conducted to determine the factors that were associated with aneurysmal recanalization after SACE. Results Stent-assisted coil embolization technically succeeded in all patients. Three cerebellar infarctions occurred on postembolization day 1, week 2, and month 2, but no other procedure-related complications developed. Immediately following SACE, 25 aneurysms (53.2%) showed no contrast filling into the aneurysmal sac. During a mean follow-up of 20.2 months, 37 lesions (78.7%) appeared completely occluded, whereas 10 lesions showed recanalization, 5 of which required additional embolization. Overall recanalization rate was 12.64% per lesion-year, and mean postoperative time to recanalization was 18 months (range, 3–36 months). In multivariable analysis, major branch involvement (hazard ratio [HR]: 7.28; p = 0.013) and the presence of residual sac filling (HR: 8.49, p = 0.044) were identified as statistically significant independent predictors of recanalization. No bleeding was encountered in follow-up monitoring. Conclusion Stent-assisted coil embolization appears feasible and safe for treatment of VBDAs. Long-term results were acceptable in a majority of patients studied, despite a relatively high rate of incomplete occlusion immediately after SACE. Major branch involvement and coiled

  19. High-Resolution C-Arm CT and Metal Artifact Reduction Software: A Novel Imaging Modality for Analyzing Aneurysms Treated with Stent-Assisted Coil Embolization.

    PubMed

    Yuki, I; Kambayashi, Y; Ikemura, A; Abe, Y; Kan, I; Mohamed, A; Dahmani, C; Suzuki, T; Ishibashi, T; Takao, H; Urashima, M; Murayama, Y

    2016-02-01

    Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P < .0001) and quantitative (P < .001) analyses showed significant reduction of the metal artifacts after application of the Metal Artifact Reduction prototype software. The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization. © 2016 by American Journal of Neuroradiology.

  20. Stent-Assisted Coil Embolization for Cavernous Carotid Artery Aneurysms

    PubMed Central

    KONO, Kenichi; SHINTANI, Aki; OKADA, Hideo; TANAKA, Yuko; TERADA, Tomoaki

    2014-01-01

    Internal carotid artery (ICA) occlusion with or without a bypass surgery is the traditional treatment for cavernous sinus (CS) aneurysms with cranial nerve (CN) dysfunction. Coil embolization without stents frequently requires retreatment because of the large size of CS aneurysms. We report the mid-term results of six unruptured CS aneurysms treated with stent-assisted coil embolization (SACE). The mean age of the patients was 72 years. The mean size of the aneurysms was 19.8 mm (range: 13–26 mm). Before treatment, four patients presented with CN dysfunction and two patients had no symptoms. SACE was performed under local or general anesthesia in three patients each. Mean packing density was 29.1% and tight packing was achieved. There were no neurological complications. CN dysfunction was cured in three patients (75%) and partly resolved in one patient (25%). Transient new CN dysfunction was observed in two patients (33%). Clinical and imaging follow-up ranged from 6 to 26 months (median: 16 months). Recanalization was observed in three patients (50%; neck remnant in two patients and dome filling in one patient), but no retreatment has yet been required. No recurrence of CN dysfunction has occurred yet. In summary, SACE increases packing density and may reduce requirement of retreatment with an acceptable cure rate of CN dysfunction. SACE may be a superior treatment for coiling without stents and be an alternative treatment of ICA occlusion for selected patients, such as older patients and those who require a high-flow bypass surgeryor cannot receive general anesthesia. PMID:24257503

  1. Stent-assisted coil embolization for cavernous carotid artery aneurysms.

    PubMed

    Kono, Kenichi; Shintani, Aki; Okada, Hideo; Tanaka, Yuko; Terada, Tomoaki

    2014-01-01

    Internal carotid artery (ICA) occlusion with or without a bypass surgery is the traditional treatment for cavernous sinus (CS) aneurysms with cranial nerve (CN) dysfunction. Coil embolization without stents frequently requires retreatment because of the large size of CS aneurysms. We report the mid-term results of six unruptured CS aneurysms treated with stent-assisted coil embolization (SACE). The mean age of the patients was 72 years. The mean size of the aneurysms was 19.8 mm (range: 13-26 mm). Before treatment, four patients presented with CN dysfunction and two patients had no symptoms. SACE was performed under local or general anesthesia in three patients each. Mean packing density was 29.1% and tight packing was achieved. There were no neurological complications. CN dysfunction was cured in three patients (75%) and partly resolved in one patient (25%). Transient new CN dysfunction was observed in two patients (33%). Clinical and imaging follow-up ranged from 6 to 26 months (median: 16 months). Recanalization was observed in three patients (50%; neck remnant in two patients and dome filling in one patient), but no retreatment has yet been required. No recurrence of CN dysfunction has occurred yet. In summary, SACE increases packing density and may reduce requirement of retreatment with an acceptable cure rate of CN dysfunction. SACE may be a superior treatment for coiling without stents and be an alternative treatment of ICA occlusion for selected patients, such as older patients and those who require a high-flow bypass surgery or cannot receive general anesthesia.

  2. Angiographic and clinical outcomes of balloon remodeling versus unassisted coil embolization in the ruptured aneurysm cohort of the GEL THE NEC study.

    PubMed

    Dabus, Guilherme; Brinjikji, Waleed; Amar, Arun P; Delgado Almandoz, Josser E; Diaz, Orlando M; Jabbour, Pascal; Hanel, Ricardo; Hui, Ferdinand; Kelly, Michael; Layton, Kennith F; Miller, Jeffrey W; Levy, Elad I; Moran, Christopher J; Suh, Dae Chul; Woo, Henry; Sellar, Robbin; Hoh, Brian; Evans, Avery; Kallmes, David F

    2018-05-01

    GEL THE NEC (GTN) was a multicenter prospective registry developed to assess the safety and efficacy of HydroSoft coils in treating intracranial aneurysms. We compared the angiographic and clinical outcomes of aneurysms treated with balloon assisted coil embolization (BACE) versus unassisted coil embolization (CE) in the ruptured aneurysm cohort. GTN was performed at 27 centers in five countries. Patients aged 21-90 years with a ruptured aneurysm 3-15 mm in size were eligible for enrollment. We analyzed demographics/comorbidities, aneurysm location, and geometry, including maximum diameter, neck size, and dome to neck ratio, immediate and long term angiographic outcomes (graded by an independent core laboratory using the modified Raymond Scale), and procedure related adverse events. Angiographic and clinical outcomes were studied using χ 2 and t tests. Of the 599 patients in the GTN, 194 met the inclusion criteria. 84 were treated with BACE and 110 with CE. There were more prior smokers in the BACE group (p=0.01). The BACE group also had more vertebrobasilar aneurysms (p=0.006) and a larger mean neck size (p=0.02). More aneurysms were immediately completely occluded in the BACE group (p=0.02) Procedure- related major morbidity and mortality were no different between the techniques (p=0.4 and p=1, respectively). In this prospective ruptured aneurysm cohort from the GTN, BACE resulted in greater occlusion rates compared with unassisted CE with similar morbi-mortality. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Stent-Assisted Coil Embolization of a Transverse-Sigmoid Sinus Diverticulum Presenting with Pulsatile Tinnitus.

    PubMed

    Li, Baomin; Lv, Xianli; Wu, Zhongxue; Cao, Xiangyu; Wang, Jun; Ge, Aili; Liu, Xinfeng; Li, Sheng

    When tinnitus is pulse-synchronous, a vascular etiology is suggested. We present a case of persistent and troublesome pulsatile tinnitus caused by a transverse-sigmoid sinus diverticulum that was endovascularly treated with stent-assisted coiling. A 39-yearold woman presented with a 4-year history of progressive pulsatile tinnitus involving the right ear. Slight pulsatile bruit was heard on the right mastoid bone by auscultation. Cerebral angiography demonstrated a diverticulum of the transverse-sigmoid sinus. The procedure was performed with an 8F guiding catheter (Cordis, USA) catheterized into the right sigmoid sinus. The diverticulum was completely coiled following deployment of a 5.5 mm-50 mm Leo stent. This patient awakened without any neurological deficit and with immediate resolution of her tinnitus. This case report describes a stent-assisted coil embolization of venous sinus diverticulum, which provides immediate resolution of pulsatile tinnitus.

  4. Flow control techniques for Onyx embolization of intracranial dural arteriovenous fistulae.

    PubMed

    Shi, Zhong-Song; Loh, Yince; Gonzalez, Nestor; Tateshima, Satoshi; Feng, Lei; Jahan, Reza; Duckwiler, Gary; Viñuela, Fernando

    2013-07-01

    Experience of flow control techniques during endovascular treatment of intracranial dural arteriovenous fistulas (DAVFs) using the Onyx liquid embolic system is reported, with an emphasis on high flow shunts. Data were evaluated in patients with DAVFs treated endovascularly with Onyx. Adjunctive techniques with coils, acrylics and balloon assistance were utilized to reduce the rate of flow with transarterial and transvenous approaches. The following types of adjunctive techniques were used in 58 patients who underwent a total of 84 embolization sessions with Onyx: transvenous coiling with transvenous or transarterial Onyx embolization in 36 patients, transarterial coiling with transarterial Onyx embolization in eight patients, arterial or venous balloon assisted technique with transarterial or transvenous Onyx embolization in 11 patients, transarterial high concentration acrylics with transarterial Onyx embolization in one patient and staged transarterial or transvenous coiling and Onyx embolization in two patients. Complete obliteration of the fistulae was achieved in 41 patients (70.7%) and 27 patients (65.9%) with high flow fistulae after endovascular treatment alone. Periprocedural complications were encountered in 16 patients, and 13 complications were associated with the adjunctive techniques. There were four neurologic and two non-neurologic clinical sequelae. Distal Onyx migration occurred in four, microcatheter retention in three and cranial neuropathy in three patients. There was one instance each of cerebellar hemorrhage, thromboembolism, coil stretching and retention, and dissection. 56 survivors experienced complete resolution or significant improvement of their symptoms on follow-up. Flow control techniques are safe and effective adjunctive methods in primary endovascular Onyx embolization of high flow DAVFs.

  5. Management of a traumatic hepatic artery pseudoaneurysm and arterioportal fistula with a combination of a stent graft and coil embolization using flow control with balloon remodeling.

    PubMed

    Flum, Andrew S; Geiger, James D; Gemmete, Joseph J; Williams, David M; Teitelbaum, Daniel H

    2009-10-01

    We describe a child who presented with a traumatic hepatic artery pseudoaneurysm and arterioportal fistula, which were subsequently managed with an endovascular stent graft and coil embolization using flow control with balloon remodeling. This case demonstrates a rarely seen condition in the pediatric population and a novel management strategy, which should be considered in the management of this complex injury.

  6. Erosion of Embolization Coils into the Renal Collecting System: Removal with Prone Transradial Renal Arteriography and Nephroscopy.

    PubMed

    Srinivasa, Ravi N; Chick, Jeffrey Forris Beecham; Hage, Anthony; Ramamurthi, Aishu; Wolf, J Stuart; Gemmete, Joseph J; Dauw, Casey A

    2017-10-01

    Removal of embolization coils eroded into the renal collecting system poses a risk of hemorrhage, which may need to be addressed with arteriography and embolization at the time of treatment. The purpose of this report is to describe a novel approach, by which prone percutaneous nephroscopic coil retrieval is coupled with simultaneous prone transradial renal arterial access to mitigate this potential complication. A retrospective chart review of the electronic medical record systems was performed from January 2008 to May 2017 to identify patients who had undergone percutaneous removal of embolization coils eroded into the renal collecting system. Patients who had migration of embolization coils into the renal collecting system who were symptomatic with pain, hydronephrosis, or infection were considered for inclusion. Patients who had coil migration, but were asymptomatic were not offered removal. Patient demographics and case characteristics were examined as were operative outcomes. A total of three patients fulfilled the study criteria. Migrated embolization coils were able to be effectively removed in all patients. Of the patients, two underwent simultaneous prone transradial renal arteriography with placement of an occlusion balloon catheter into the segmental artery of interest. In one patient, significant arterial bleeding was encountered after coil removal, which was effectively addressed with simultaneous arteriography and glue embolization. Erosion of embolization coils into the renal collecting system, while rare, may be a significant long-term complication of coil embolization. Combining nephroscopy with prone transradial arteriography in preparation for procedure-associated hemorrhage may make removal of migrated coils safer.

  7. Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rabellino, Martin, E-mail: jmrabellino@hotmail.com; Garcia-Nielsen, Luis, E-mail: luisgarcia@hospiten.es; Zander, Tobias, E-mail: tobiaszander@hospiten.es

    2011-02-15

    Mycotic aneurysms are uncommon, especially those located in visceral arteries. We present a case of a patient with two visceral mycotic aneurysms due to bacterial endocarditis, one located in right upper pole renal artery and the second in the splenic artery. Both aneurysms were treated as endovascular embolization using microcoils. In the aneurysm located at the renal artery, the technique of stent-assisted coils embolization was preferred to avoid coils migration due to its wide neck. The stent used was the Solitaire AB, which was designed for the treatment of intracranial aneurysms and was used recently in acute stroke as amore » mechanical thrombectomy device. Complete embolization of the aneurysm was achieved, preserving all the arterial branches without nephrogram defects in the final angiogram.« less

  8. Endovascular embolization

    MedlinePlus

    ... plastic particles, glue, metal coils, foam, or a balloon through it to seal off the faulty blood vessel. (If coils are used, it is called coil embolization.) This procedure can take several hours.

  9. Balloon-Assisted Technique for Trapped Microcatheter Retrieval Following Onyx Embolization

    PubMed Central

    Santillan, A.; Zink, W.; Knopman, J.; Riina, H.; Gobin, Y.P.

    2009-01-01

    Summary During embolization of a large frontal arteriovenous malformation (AVM), Onyx-18 (eV3) was injected into an M3 branch of the middle cerebral artery via a Marathon microcatheter (eV3). After 40 minutes of embolization, the microcatheter could not be retracted due to fixation within the Onyx cast despite prolonged, robust attempts. A balloon microcatheter (HyperformTM, eV3) was advanced distally and inflated to provide distal counter tension, allowing microcatheter retrieval with minimal traction on the vasculature. PMID:20465885

  10. Balloon-augmented Onyx embolization of cerebral arteriovenous malformations using a dual-lumen balloon: a multicenter experience.

    PubMed

    Spiotta, Alejandro M; James, Robert F; Lowe, Stephen R; Vargas, Jan; Turk, Aquilla S; Chaudry, M Imran; Bhalla, Tarun; Janjua, Rashid M; Delaney, John J; Quintero-Wolfe, Stacey; Turner, Raymond D

    2015-10-01

    Conventional Onyx embolization of cerebral arteriovenous malformations (AVMs) requires lengthy procedure and fluoroscopy times to form an adequate 'proximal plug' which allows forward nidal penetration while preventing reflux and non-targeted embolization. We review our experience with balloon-augmented Onyx embolization of cerebral AVMs using a dual-lumen balloon catheter technique designed to minimize these challenges. Retrospectively acquired data for all balloon-augmented cerebral AVM embolizations performed between 2011 and 2014 were obtained from four tertiary care centers. For each procedure, at least one Scepter C balloon catheter was advanced into the AVM arterial pedicle of interest and Onyx embolization was performed through the inner lumen after balloon inflation via the outer lumen. Twenty patients underwent embolization with the balloon-augmented technique over 24 discreet treatment episodes. There were 37 total arterial pedicles embolized with the balloon-augmented technique, a mean of 1.9 per patient (range 1-5). The treated AVMs were heterogeneous in their location and size (mean 3.3±1.6 cm). Mean fluoroscopy time for each procedure was 48±26 min (28 min per embolized pedicle). Two Scepter C balloon catheter-related complications (8.3% of embolization sessions, 5.4% of pedicles embolized) were observed: an intraprocedural rupture of a feeding pedicle and fracture and retention of a catheter fragment. This multicenter experience represents the largest reported series of balloon-augmented Onyx embolization of cerebral AVMs. The technique appears safe and effective in the treatment of AVMs, allowing more efficient and controlled injection of Onyx with a decreased risk of reflux and decreased fluoroscopy times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Dissecting Vertebral Artery Aneurysm Presenting Regrowth After Stent-Assisted Coil Embolization in Acute Stage.

    PubMed

    Hijikata, Takamichi; Baba, Eiichi; Shirokane, Kazutaka; Tsuchiya, Atsushi; Nomura, Motohiro

    2018-06-01

    For a case of dissecting vertebral artery aneurysm (DVAA) in a dominant vertebral artery (VA) or posterior inferior cerebellar artery (PICA)-involving lesion, stent-assisted coil embolization (SACE) is an effective technique to preserve blood flow of the VA. A 41-year-old man presented with subarachnoid hemorrhage. Angiography demonstrated DVAA on the left VA just distal to the PICA, and the right VA was thinner than the left. For this case, SACE was performed to preserve the left VA and PICA. On the 10th day, angiography showed recurrence of the dissection. The dissected portion had thickened and extended to both distal and proximal sides involving the PICA origin and proximal portion to the PICA. A second endovascular embolization was performed and the recurrent dissecting aneurysm was embolized including the main VA cavity. In cases of DVAA, there is a possibility of recurrence after SACE, if a dissecting cavity remains unembolized. Therefore, total embolization is necessary under close observation from multiple angles, including the down-the-barrel view.

  12. Progressive Occlusion of Small Saccular Aneurysms Incompletely Occluded After Stent-Assisted Coil Embolization : Analysis of Related Factors and Long-Term Outcomes.

    PubMed

    Lim, Jeong Wook; Lee, Jeongjun; Cho, Young Dae

    2017-08-08

    Incompletely occluded aneurysms after coil embolization are subject to recanalization but occasionally progress to a totally occluded state. Deployed stents may actually promote thrombosis of coiled aneurysms. We evaluated outcomes of small aneurysms (<10 mm) wherein saccular filling with contrast medium was evident after stent-assisted coiling, assessing factors implicated in subsequent progressive occlusion. Between September 2012 and June 2016, a total of 463 intracranial aneurysms were treated by stent-assisted coil embolization. Of these, 132 small saccular aneurysms displayed saccular filling with contrast medium in the immediate aftermath of coiling. Progressive thrombosis was defined as complete aneurysmal occlusion at the 6‑month follow-up point. Rates of progressive occlusion and factors predisposing to this were analyzed via binary logistic regression. In 101 (76.5%) of the 132 intracranial aneurysms, complete occlusion was observed in follow-up imaging studies at 6 months. Binary logistic regression analysis indicated that progressive occlusion was linked to smaller neck diameter (odds ratio [OR] = 1.533; p = 0.003), hyperlipidemia (OR = 3.329; p = 0.036) and stent type (p = 0.031). The LVIS stent is especially susceptible to progressive thrombosis, more so than Neuroform (OR = 0.098; p = 0.008) or Enterprise (OR = 0.317; p = 0.098) stents. In 57 instances of progressive thrombosis, followed for ≥12 months (mean 25.0 ± 10.7 months), 56 (98.2%) were stable, with minor recanalization noted once (1.8%) and no major recanalization. Aneurysms associated with smaller diameter necks, hyperlipidemic states and LVIS stent deployment may be inclined to possible thrombosis, if occlusion immediately after stent-assisted coil embolization is incomplete. In such instances, excellent long-term durability is anticipated.

  13. A Mechanical Coil Insertion System for Endovascular Coil Embolization of Intracranial Aneurysms

    PubMed Central

    Haraguchi, K.; Miyachi, S.; Matsubara, N.; Nagano, Y.; Yamada, H.; Marui, N.; Sano, A.; Fujimoto, H.; Izumi, T.; Yamanouchi, T.; Asai, T.; Wakabayashi, T.

    2013-01-01

    Summary Like other fields of medicine, robotics and mechanization might be introduced into endovascular coil embolization of intracranial aneurysms for effective treatment. We have already reported that coil insertion force could be smaller and more stable when the coil delivery wire is driven mechanically at a constant speed. Another background is the difficulty in synchronizing operators' minds and hands when two operators control the microcatheter and the coil respectively. We have therefore developed a mechanical coil insertion system enabling a single operator to insert coils at a fixed speed while controlling the microcatheter. Using our new system, the operator manipulated the microcatheter with both hands and drove the coil using foot switches simultaneously. A delivery wire force sensor previously reported was used concurrently, allowing the operator to detect excessive stress on the wire. In vitro coil embolization was performed using three methods: simple mechanical advance of the coil; simple mechanical advance of the coil with microcatheter control; and driving (forward and backward) of the coil using foot switches in addition to microcatheter control. The system worked without any problems, and did not interfere with any procedures. In experimental coil embolization, delivery wire control using the foot switches as well as microcatheter manipulation helped to achieve successful insertion of coils. This system could offer the possibility of developing safer and more efficient coil embolization. Although we aim at total mechanization and automation of procedures in the future, microcatheter manipulation and synchronized delivery wire control are still indispensable using this system. PMID:23693038

  14. Transcatheter Coil Embolization of Splenic Artery Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Satoshi, E-mail: s-yama@hyo-med.ac.jp; Hirota, Shozo; Maeda, Hiroaki

    2008-05-15

    The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10).more » The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm.« less

  15. Double-Balloon-Assisted n-Butyl-2-Cyanoacrylate Embolization of Intrahepatic Arterioportal Shunt Prior to Chemoembolization of Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takao, Hidemasa, E-mail: takaoh-tky@umin.ac.jp; Shibata, Eisuke; Ohtomo, Kuni

    A case of multiple hepatocellular carcinomas with a severe intrahepatic arterioportal shunt that was successfully embolized with n-butyl-2-cyanoacrylate with coaxial double-balloon occlusion prior to transcatheter arterial chemoembolization is presented. A proximal balloon positioned at the proper hepatic artery was used for flow control, and a coaxial microballoon, positioned in the closest of three arterial feeding branches to the arterioportal shunt, was used to control the delivery of n-butyl-2-cyanoacrylate. This coaxial double-balloon technique can prevent proximal embolization and distal migration of n-butyl-2-cyanoacrylate and enable precise control of the distribution of n-butyl-2-cyanoacrylate. It could also be applicable to n-butyl-2-cyanoacrylate embolization for othermore » than intrahepatic arterioportal shunt.« less

  16. Successful embolization using interlocking detachable coils for a congenital extrahepatic portosystemic venous shunt in a child.

    PubMed

    Yamagami, Takuji; Yoshimatsu, Rika; Matsumoto, Tomohiro; Terayama, Koshi; Nishiumra, Akira; Maeda, Yousuke; Nishimura, Tsunehiko

    2007-11-01

    The authors report the case of a 6-year-old boy with a congenital extrahepatic portosystemic venous shunt. He had hyperammonemia. The shunt was 18 mm in diameter and located between the inferior mesenteric vein and the left internal iliac vein. The flow in the shunt was very rapid. After decreasing blood flow by inflating a balloon catheter inserted into the left internal iliac vein from the femoral vein, a microcatheter was coaxially advanced to the shunt to embolize the shunt. Embolization was successfully performed with interlocking detachable coils and microcoils without any complication. This patient's hyperammonemia resolved soon after the procedure.

  17. Stent-assisted coil embolization of aneurysms with small parent vessels: safety and efficacy analysis.

    PubMed

    Kühn, Anna Luisa; Hou, Samuel Y; Puri, Ajit S; Silva, Christine F; Gounis, Matthew J; Wakhloo, Ajay K

    2016-06-01

    Stent-assisted coil embolization (SACE) is a viable therapeutic approach for wide-neck intracranial aneurysms. However, it can be technically challenging in small cerebral vessels (≤2 mm). To present our experience with stents approved for SACE in aneurysms with small parent arteries. All patients who underwent stent-assisted aneurysm treatment with either a Neuroform or an Enterprise stent device at our institution between June 2006 and October 2012 were identified. Additionally, we evaluated each patient's vascular risk factors, aneurysm characteristics (ruptured vs non-ruptured, incidental finding, recanalized) and follow-up angiography data. A total of 41 patients with 44 aneurysms met our criteria, including 31 women and 10 men. Most of the aneurysms were located in the anterior circulation (75%). Stent placement in vessels 1.2-2 mm in diameter was successful in 93.2%. Thromboembolic complications occurred in 6 cases and vessel straightening was seen in 1 case only. Initial nearly complete to complete aneurysm obliteration was achieved in 88.6%. Six-month follow-up angiography showed coil compaction in three cases, one asymptomatic in-stent stenosis and stent occlusion. Twelve to 20-months' follow-up showed stable coil compaction in two patients compared with previous follow-up, and aneurysm recanalization in two patients. Twenty-four to 36-months' follow-up showed further coil compaction in one of these patients and aneurysm recanalization in a previous case of stable coil compaction on mid-term follow-up. Our results suggest that SACE of aneurysms with small parent vessels is feasible in selected cases and shows good long-term patency rates of parent arteries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter.

    PubMed

    Kim, Jin Woo; Kim, Byung Moon; Park, Keun Young; Kim, Dong Joon; Kim, Dong Ik

    2016-05-01

    Utilization of a dual-lumen balloon may improve Onyx penetration into isolated dural arteriovenous fistulas (i-DAVFs). To compare the results of Onyx embolization using a dual-lumen balloon with those using a non-balloon catheter for i-DAVFs. Twenty-nine patients underwent Onyx embolization for i-DAVFs using a non-balloon (n = 14) or a dual-lumen balloon catheter (n = 15). Since its introduction, a dual-lumen balloon catheter has been preferred. We compared the dual-lumen balloon group with the non-balloon catheter group regarding angiographic outcome, treatment-related complications, total procedural time, Onyx injection time, and the number of feeders requiring embolization. The dual-lumen balloon group showed complete occlusion of i-DAVFs in 13 and near-complete in 2 patients, while the non-balloon group showed complete occlusion in 5, near-complete in 5, and incomplete in 4 patients (P < .05). Treatment-related complications occurred in 2 patients: 1 in the non-balloon group and 1 in the dual-lumen balloon group. The mean total procedural time was 62 ± 32 minutes in the dual-lumen balloon and 171 ± 88 minutes in the non-balloon group (P < .05). The mean Onyx injection time was 10 ± 6 minutes in the dual-lumen balloon and 49 ± 32 minutes in the non-balloon group (P < .05). The median number of feeders requiring embolization was 1 (range, 1-3) in the dual-lumen balloon and 2 (range, 1-4) in the non-balloon group (P < .05). Utilization of a dual-lumen balloon catheter for Onyx embolization of i-DAVF seemed to significantly increase the immediate complete occlusion rate and decrease total procedural time, Onyx injection time, and number of feeders requiring embolization.

  19. A comparison of different transarterial embolization techniques for direct carotid cavernous fistulas: a single center experience in 32 patients

    PubMed Central

    Lu, Xiaojian; Hussain, Mohammed; Ni, Lanchun; Huang, Qinfeng; Zhou, Fei; Gu, Zhikai; Chen, Jian; Ding, Yuchuan; Xu, Feng

    2014-01-01

    Objective Transarterial treatment of direct carotid cavernous fistulas (DCCF) via embolic materials has been well documented. This study reports, validates, and compares with existing literature our experience treating DCCFs via endovascular approaches by using detachable balloons, coils, and covered stents. Methods Between June 2006 to October 2011, 32 patients (21 male, 11 female) with 32 DCCFs (30 traumatic, 2 spontaneous cavernous ICA aneurysms) were embolized endovascularly. Followup was performed for at least 6 months. Results Among the 32 DCCFs, 21 (65.6%) were embolized using detachable balloons, eight (25.0%) with coils, one (3.1%) with balloons and coils, and two (6.3%) with covered stents. Complete DCCF obliteration was achieved in 31 (96.9%) cases. One fistula failed to respond due to premature balloon detachment. Intracranial bruit in 31 (100%) chemosis and exophthalmos in 28 (100%) cases resolved after embolization. Visual acuity and oculomotor palsy improved in 18 (90%) and 18 (69.2%) cases, respectively. There was no evidence of DCCF recurrence. Thirteen DCCFs were followed up by MRI and five by DSA. In these cases, four (4/13, 30.8%) balloon-embolized DCCFs showed pseudoaneurysms. Three patients were asymptomatic; one had minor left oculomotor palsy. Conclusions Our results correlate and reinforce literature regarding endovascular treatment of DCCFs. Application of Transarterial embolization with detachable balloons, despite extensive use has been decreasing. Coil embolization is an effective and safe alternative for treatment, especially when balloon embolization fails. Covered stent placement may be used as another alternative for selected cases. PMID:25566340

  20. Computational study for the effects of coil configuration on blood flow characteristics in coil-embolized cerebral aneurysm.

    PubMed

    Otani, Tomohiro; Ii, Satoshi; Shigematsu, Tomoyoshi; Fujinaka, Toshiyuki; Hirata, Masayuki; Ozaki, Tomohiko; Wada, Shigeo

    2017-05-01

    Coil embolization of cerebral aneurysms with inhomogeneous coil distribution leads to an incomplete occlusion of the aneurysm. However, the effects of this factor on the blood flow characteristics are still not fully understood. This study investigates the effects of coil configuration on the blood flow characteristics in a coil-embolized aneurysm using computational fluid dynamics (CFD) simulation. The blood flow analysis in the aneurysm with coil embolization was performed using a coil deployment (CD) model, in which the coil configuration was constructed using a physics-based simulation of the CD. In the CFD results, total flow momentum and kinetic energy in the aneurysm gradually decayed with increasing coil packing density (PD), regardless of the coil configuration attributed to deployment conditions. However, the total shear rate in the aneurysm was relatively high and the strength of the local shear flow varied based on the differences in coil configuration, even at adequate PDs used in clinical practice (20-25 %). Because the sufficient shear rate reduction is a well-known factor in the blood clot formation occluding the aneurysm inside, the present study gives useful insight into the effects of coil configuration on the treatment efficiency of coil embolization.

  1. Clinical Application of Insertion Force Sensor System for Coil Embolization of Intracranial Aneurysms.

    PubMed

    Matsubara, Noriaki; Miyachi, Shigeru; Izumi, Takashi; Yamada, Hiroyuki; Marui, Naoki; Ota, Keisuke; Tajima, Hayato; Shintai, Kazunori; Ito, Masashi; Imai, Tasuku; Nishihori, Masahiro; Wakabayashi, Toshihiko

    2017-09-01

    In endovascular embolization for intracranial aneurysms, it is important to properly control the coil insertion force. However, the force can only be subjectively detected by the subtle feedback experienced by neurointerventionists at their fingertips. The authors envisioned a system that would objectively sense and quantify that force. In this article, coil insertion force was measured in cases of intracranial aneurysm using this sensor, and its actual clinical application was investigated. The sensor consists of a hemostatic valve (Y-connector). A little flexure was intentionally added in the device, and it creates a bend in the delivery wire. The sensor measures the change in the position of the bent wire depending on the insertion force and translates it into a force value. Using this, embolization was performed for 10 unruptured intracranial aneurysms. The sensor adequately recorded the force, and it reflected the operators' usual clinical experience. The presence of the sensor did not affect the procedures. The sensor enabled the operators to objectively note and evaluate the insertion force and better cooperative handling was possible. Additionally, other members of the intervention team shared the information. Force records demonstrated the characteristic patterns according to every stage of coiling (framing, filling, and finishing). The force sensor system adequately measured coil insertion force in intracranial aneurysm coil embolization procedures. The safety of this sensor was demonstrated in clinical application for the limited number of patients. This system is useful adjunct for assisting during coil embolization for an intracranial aneurysm. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Balloon augmented Onyx embolization utilizing a dual lumen balloon catheter: utility in the treatment of a variety of head and neck lesions.

    PubMed

    Spiotta, Alejandro M; Miranpuri, Amrendra S; Vargas, Jan; Magarick, Jordan; Turner, Raymond D; Turk, Aquilla S; Chaudry, M Imran

    2014-09-01

    Endovascular embolization for tumors and vascular malformations has emerged as an important preoperative adjunct prior to resection. We describe the advantages of utilizing a recently released dual lumen balloon catheter for ethylene vinyl alcohol copolymer, also known as Onyx (ev3, Irvine, California, USA), embolization for a variety of head and neck pathologies. A retrospective review of all cases utilizing the Scepter C balloon catheter (MicroVention Inc, Tustin, California, USA) for use in balloon augmented embolization was performed over a 4 month period from October 2012 to February 2013 at the Medical University of South Carolina, Charleston, South Carolina, USA. Charts and angiographic images were reviewed. Representative cases involving diverse pathologies are summarized and illustrate the observed advantages of balloon augmented Onyx embolization with a dual lumen balloon catheter. Balloon augmented Onyx embolization utilizing a novel dual lumen balloon catheter was employed to treat both ruptured and unruptured arteriovenous malformations, intracranial dural arteriovenous fistulae, intracranial neoplasms, carotid body tumors, a thyroid mass, and an extracranial arteriovenous fistula. The dual lumen balloon catheter has several advantages for use with Onyx embolization over older devices, including more efficient proximal plug formation and enhanced navigability for placement deep within the pedicles. The balloon augmented Onyx embolization technique represents a valuable tool to add to the armamentarium of the neurointerventionalist to address a variety of head and neck lesions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Relationship between Angiographic Results and Morphology in Sidewall Intracranial Aneurysms after Stent-Assisted Coil Embolization.

    PubMed

    Nii, Kouhei; Aikawa, Hiroshi; Tsutsumi, Masanori; Eto, Ayumu; Iko, Minoru; Sakamoto, Kimiya; Inoue, Ritsuro; Mitsutake, Takafumi; Hanada, Hayatsura; Kazekawa, Kiyoshi

    2016-03-01

    Stent-assisted coil embolization (SACE) is used to address wide-necked or complex aneurysms. However, as they may recanalize after SACE, predictors of recanalization are needed. We investigated the relationship between follow-up angiographic results and the morphology of sidewall (SW) aneurysms in patients treated by SACE. Between September 2010 and September 2014, we performed 80 SACE procedures for SW intracranial aneurysms. Angiographic findings, obtained immediately after the procedure, 3-6 months thereafter, and when aneurysmal recanalization was suspected on MR angiogram scan, were recorded. Morphologically, the SW aneurysms were classified as "outside" (OS) and "partially inside" (PI) based on the curve of the axes of the proximal or distal parent artery with respect to the aneurysmal neck. Follow-up angiographic studies on OS- and PI SW aneurysms were compared. On the initial angiograms, we classified 42 aneurysms as OS and 38 as PI. Immediately after SACE, there was no significant difference in the angiographic findings on OS and PI aneurysms. However, on follow-up angiograms, there was a significant difference in the rate of spontaneous improvement (4 of 42 [OS] versus 21 of 38 [PI], P = .001). We performed additional coil embolization to treat 3 recanalized OS aneurysms. SW aneurysms classified morphologically as PI tended to occlude progressively even after incomplete occlusion by SACE. In contrast, aneurysms classified as OS must be observed carefully after SACE. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. Initial experience with dual-lumen balloon catheter injection for preoperative Onyx embolization of skull base paragangliomas.

    PubMed

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Yang, George L; Wanna, George B; Mocco, J

    2016-06-01

    OBJECT Paragangliomas are highly vascular head and neck tumors for which preoperative embolization is often considered to facilitate resection. The authors evaluated their initial experience using a dual-lumen balloon to facilitate preoperative embolization in 5 consecutive patients who underwent preoperative transarterial Onyx embolization assisted by the Scepter dual-lumen balloon catheter between 2012 and 2014. OBJECT The authors reviewed the demographic and clinical records of 5 patients who underwent Scepter-assisted Onyx embolization of a paraganglioma followed by resection between 2012 and 2014. Descriptive statistics of clinical outcomes were assessed. RESULTS Five patients (4 with a jugular and 1 with a vagal paraganglioma) were identified. Three paragangliomas were embolized in a single session, and each of the other 2 were completed in 3 staged sessions. The mean volume of Onyx used was 14.3 ml (range 6-30 ml). Twenty-seven vessels were selectively catheterized for embolization. All patients required selective embolization via multiple vessels. Two patients required sacrifice of parent vessels (1 petrocavernous internal carotid artery and 1 vertebral artery) after successful balloon test occlusion. One patient underwent embolization with Onyx-18 alone, 2 with Onyx-34 alone, and 1 with Onyx-18 and -34. In each case, migration of Onyx was achieved within the tumor parenchyma. The mean time between embolization and resection was 3.8 days (range 1-8 days). Gross-total resection was achieved in 3 (60%) patients, and the other 2 patients had minimal residual tumor. The mean estimated blood loss during the resections was 556 ml (range 200-850 ml). The mean postoperative hematocrit level change was -17.3%. Two patients required blood transfusions. One patient, who underwent extensive tumor penetration with Onyx, developed a temporary partial cranial nerve VII palsy that resolved to House-Brackmann Grade I (out of VI) at the 6-month follow-up. One patient

  5. Radio aneurysm coils for noninvasive detection of cerebral embolization failures: a preliminary study.

    PubMed

    Mohammadi, Abdolreza Rashidi; Chen, Keqin; Ali, Mohamed Sultan Mohamed; Takahata, Kenichi

    2011-12-15

    The rupture of a cerebral aneurysm is the most common cause of subarachnoid hemorrhage. Endovascular embolization of the aneurysms by implantation of Guglielmi detachable coils (GDC) has become a major treatment approach in the prevention of a rupture. Implantation of the coils induces formation of tissues over the coils, embolizing the aneurysm. However, blood entry into the coiled aneurysm often occurs due to failures in the embolization process. Current diagnostic methods used for aneurysms, such as X-ray angiography and computer tomography, are ineffective for continuous monitoring of the disease and require extremely expensive equipment. Here we present a novel technique for wireless monitoring of cerebral aneurysms using implanted embolization coils as radiofrequency resonant sensors that detect the blood entry. The experiments show that commonly used embolization coils could be utilized as electrical inductors or antennas. As the blood flows into a coil-implanted aneurysm, parasitic capacitance of the coil is modified because of the difference in permittivity between the blood and the tissues grown around the coil, resulting in a change in the coil's resonant frequency. The resonances of platinum GDC-like coils embedded in aneurysm models are detected to show average responses of 224-819 MHz/ml to saline injected into the models. This preliminary demonstration indicates a new possibility in the use of implanted GDC as a wireless sensor for embolization failures, the first step toward realizing long-term, noninvasive, and cost-effective remote monitoring of cerebral aneurysms treated with coil embolization. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Therapy-resistant nephrolithiasis following renal artery coil embolization

    PubMed Central

    2013-01-01

    Background Transcatheter renal artery embolization is an effective and minimally invasive treatment option for acute renal bleeding. Early post-interventional complications include groin hematoma, incomplete embolization, coil misplacement and coil migration. Late complications are rare and mostly related to coil migration. Case presentation A 22-year-old woman with a history of recurrent stone disease and a lumbal meningomyelocele underwent bilateral open pyelolithotomy for bilateral staghorn calculi. Post-operatively, acute hemorrhage of the left kidney occurred and selective arterial coil embolization of a lower pole interlobular renal artery was performed twice. Four years after this intervention the patient presented with a new 15.4 mm stone in the lower calyx of the left kidney. After two extracorporeal shock wave lithotripsy treatments disintegration of the stone was not detectable. Therefore, flexible ureterorenoscopy was performed and revealed that the stone was adherent to a partially intraluminal metal coil in the lower renal calyx. The intracalyceal part of the coil and the adherent stone were successfully removed using the holmium laser. Conclusion Therapy-resistant nephrolithiasis was caused by a migrated metal coil, which was placed four years earlier for the treatment of acute post-operative renal bleeding. Renal coils in close vicinity to the renal pelvis can migrate into the collecting system and trigger renal stone formation. Extracorporeal shock wave lithotripsy seems to be inefficient for these composite stones. Identification of these rare stones is possible during retrograde intrarenal surgery. It also enables immediate stone disintegration and removal of the stone fragments and the intraluminal coil material. PMID:23758632

  7. [Coil Embolization of Bronchial Artery Aneurysm;Report of a Case].

    PubMed

    Hagiwara, Kenichi; Moriya, Hiroshi; Sato, Yoshiyuki

    2018-05-01

    An 82-year-old male was admitted due to mild chest discomfort. Enhanced computed tomography showed a large bronchial artery aneurysm(BAA) of 26×27 mm at the left hilus. To avoid the rupture of BAA, coil embolization alone was performed. There has been no enlargement of BAA for these 4 years. In general, coil embolization only should be indicated in a patient with BAA with a stalk because of thoracic endovascular aortic repair (TEVAR) being off-label and low cost performance. TEVAR would be considered as a last resort only in case of enlarging BAA even after coil embolization.

  8. Long-Term Follow-up After Embolization of Pulmonary Arteriovenous Malformations with Detachable Silicone Balloons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andersen, Poul Erik; Kjeldsen, Anette D.

    2008-05-15

    Long-term follow-up results after embolization of 13 pulmonary arteriovenous malformations in 10 patients by use of 14 detachable silicone balloons are given. Patients were followed for a mean of 99 months (range, 63-123 months) with chest x-rays and for a mean of 62 months (range, 3-101 months) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not available anymore, but use of these balloons for embolization of pulmonary arteriovenousmore » malformations has been shown to be a safe and precise method, with immediate occlusion of the feeding artery and with long-lasting occlusion, even though many balloons deflate with time, leaving a fibrotic scar replacing the pulmonary arteriovenous malformation. No case of recanalization has been discovered, and these results seem to justify a reduced number of controls of these balloon-embolized malformations.« less

  9. Percutaneous coil embolization of massive pelvic pseudoaneurysm in an infant.

    PubMed

    Lillis, Anna P; Shaikh, Raja; Alomari, Ahmad I; Chaudry, Gulraiz

    2015-06-01

    Iatrogenic pseudoaneurysm formation is an uncommon but potentially serious complication of cardiac catheterization. This case report describes diagnosis and treatment of a large left external iliac artery pseudoaneurysm in a 3-month-old boy following cardiac catheterization and aortic balloon dilatation for aortic coarctation. A 4-cm pulsatile mass in the left hemipelvis was discovered on MRI performed 6 weeks later for possible tethered spinal cord. Sonography and angiography showed a large pseudoaneurysm of the left external iliac artery just distal to the iliac bifurcation with no flow in the external iliac artery distal to the pseudoaneurysm. Percutaneous US-guided thrombin injection was performed twice, with partial recanalization after each treatment. The residual portion of the pseudoaneurysm was then successfully embolized with percutaneous coils deployed under US and fluoroscopic guidance.

  10. Balloon-Occluded Retrograde Transvenous Embolization of a Pelvic Arteriovenous Malformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitsuzaki, Katsuhiko; Yamashita, Yasuyuki; Utsunomiya, Daisuke

    1999-11-15

    We successfully performed embolization therapy for a pelvic arteriovenous malformation by the retrograde transvenous approach using a liquid embolic material. This malformation was unique in that it had a single draining vein, which allowed this technique employing an occlusion balloon.

  11. Use of the TriSpan Coil to Facilitate the Transcatheter Occlusion of Pulmonary Arteriovenous Malformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cil, Barbaros E., E-mail: barbaroscil@hotmail.com, E-mail: barbaros@hacettepe.edu.tr; Erdogan, Cueneyt; Akmangit, Ilkay

    Pulmonary arteriovenous malformation (PAVM) is a rare vascular malformation of the lung which may occur as an isolated entity or in association with hereditary hemorrhagic telangiectasia (HHT). Because of considerable risk of serious complications such as cerebral embolism, brain abscess and pulmonary hemorrhage, definitive treatment should be considered in most patients. Embolization with coils or detachable balloons is currently the preferred treatment. Paradoxical embolization of coils and balloons may happen, especially in patients with PAVMs with large feeding arteries. In this report we present our initial experience with the use of the TriSpan coil to lower the risk of coilmore » migration during the transcatheter occlusion of PAVMs.« less

  12. Interlocking Detachable Coil Embolization by Technique of Dumbbell-Shaped Framing and Filling and Bridge Formation Under Balloon Dilatation for Huge Conglomerate Pulmonary Arteriovenous Malformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawai, Nobuyuki, E-mail: nobkawai@wakayama-med.ac.jp; Sato, Morio, E-mail: morisato@mail.wakayama-med.ac.jp; Minamiguchi, Hiroyuki, E-mail: hiromina4@hotmail.com

    A 60-year-old woman presented with a conglomerate pulmonary arteriovenous malformation (PAVM) size 8.2 Multiplication-Sign 7.2 cm on chest X-ray. Feeding arteries were A{sub a}{sup 7} and A{sub b}{sup 7}, A{sup 8}, and A{sup 10}. The diameter and length of the A{sub b}{sup 7} neck were 15.5 and 16 mm, respectively. After percutaneous transcatheter embolization of A{sup 8} and A{sup 10}, PTE of A{sub a}{sup 7} and A{sub b}{sup 7} was conducted under balloon occlusion with interlocking detachable coils using a technique of dumbbell-shaped framing and filling, making a bridge from A{sub b}{sup 7} to the trunk of A{sup 9} andmore » A{sup 10}across A{sup 7}. Follow-up computed tomography 10 months after treatment showed marked shrinkage of the PAVM.« less

  13. Portal vein embolization with plug/coils improves hepatectomy outcome.

    PubMed

    Malinowski, Maciej; Geisel, Dominik; Stary, Victoria; Denecke, Timm; Seehofer, Daniel; Jara, Maximillian; Baron, Annekathrin; Pratschke, Johann; Gebauer, Bernhard; Stockmann, Martin

    2015-03-01

    Portal vein embolization (PVE) has become the standard of care before extended hepatectomy. Various PVE methods using different embolization materials have been described. In this study, we compared PVE with polyvinyl alcohol particles alone (PVA only) versus PVA with plug or coils (PVA + plug/coils). Patients undergoing PVE before hepatectomy were included. PVA alone was used until December 2013, thereafter plug or coils were placed in addition. The volume of left lateral liver lobe (LLL), clinical parameters, and liver function tests were measured before PVE and resection. A total of 43 patients were recruited into the PVA only group and 42 were recruited into the PVA + plug/coils group. There were no major differences between groups except significantly higher total bilirubin level before PVE in the PVA only group, which improved before hepatectomy. Mean LLL volume increased by 25.7% after PVE in the PVA only group and by 44% in the PVA + plug/coils group (P < 0.001). Recanalization was significantly less common in the PVA + plug/coils group. In multivariate regression, initial LLL volume and use of plug or coils were the only parameters influencing LLL volume increase. The postoperative liver failure rate was significantly reduced in PVA + plug/coils group (P = <0.001). PVE using PVA particles together with plug or coils is a safe and efficient method to increase future liver remnant volume. The additional central embolization with plug or coils led to an increased hypertrophy, due to lower recanalization rates, and subsequently decreased incidence of postoperative liver failure. No additional procedure-specific complications were observed in this series. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Onyx embolization using dual-lumen balloon catheter: initial experience and technical note.

    PubMed

    Paramasivam, Srinivasan; Niimi, Yasunari; Fifi, Johanna; Berenstein, Alejandro

    2013-10-01

    Onyx as an embolization agent for the management of vascular malformation is well established. We report our initial experience with dimethyl-sulphoxide (DMSO) compatible double lumen balloon catheters used for Onyx embolization. Between December 2011 and March 2013, we treated 22 patients aged between 1.5 to 70years with two types of DMSO compatible dual-lumen balloon catheters (Scepter C and Ascent) to treat dural arteriovenous fistulas, brain arteriovenous malformation (AVM) with dural feeders, mandibular, facial, lingual, vertebral and paravertebral AVMs. The catheter has good navigability, compliant balloon on inflation formed a "plug" that has more resistance than Onyx plug enhancing better penetration. During injection, the balloon remained stable without spontaneous deflation or rupture and withstood the pressure build-up well. The retrieval of the catheter in most cases took less than a minute (19/28) while in five, it was less than five minutes and in the remaining four, it was longer that includes a trapped catheter on prolonged attempted retrieval resulted in an epidural hematoma, requiring emergent surgical evacuation. The fluoroscopy time is reduced, as we do not form a proximal onyx plug, the injection time is shorter along with easy and instantaneous removal of the catheter after balloon deflation in most cases. Dual-lumen balloon catheter Onyx embolization is a safe and effective technique. Currently, an important tool to circumvent some of the shortcomings associated with Onyx embolization. The catheter has good navigability, the balloon has stability, tolerance, enhances penetrability. It is easy to retrieve the microcatheter. With the experience gained, and with more compliant balloon catheters available, this technique can be applied to cerebral vessels in near future. Copyright © 2013. Published by Elsevier Masson SAS.

  15. A Retrograde Transvenous Embolization Technique with Balloon-Assisted Arterial Aspiration for a Peripheral Arteriovenous Malformation with a Venous Pouch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhara, Asako, E-mail: kuhara-asako@med.kurume-u.ac.jp; Tanaka, Norimitsu; Koganemaru, Masamichi

    Management of arteriovenous malformations (AVMs) is challenging, and there is no consensus regarding either the ideal approach or the treatment timing. Percutaneous embolization is the most frequent approach currently used and is considered the first-line technique for AVMs. There is an ongoing discussion about the best technical approach to embolize AVMs. AVMs associated with a dominant outflow vein (DOV) are rare. Embolization of both the DOV and the nidus is considered more effective. Herein, we report a novel technique of transvenous embolization of a DOV under negative pressure from an arterial balloon catheter in a case of a peripheral AVM.more » This technique allows the embolization of the DOV and the nidus retrogradely.« less

  16. Aneurysm permeability following coil embolization: packing density and coil distribution

    PubMed Central

    Chueh, Ju-Yu; Vedantham, Srinivasan; Wakhloo, Ajay K; Carniato, Sarena L; Puri, Ajit S; Bzura, Conrad; Coffin, Spencer; Bogdanov, Alexei A; Gounis, Matthew J

    2015-01-01

    Background Rates of durable aneurysm occlusion following coil embolization vary widely, and a better understanding of coil mass mechanics is desired. The goal of this study is to evaluate the impact of packing density and coil uniformity on aneurysm permeability. Methods Aneurysm models were coiled using either Guglielmi detachable coils or Target coils. The permeability was assessed by taking the ratio of microspheres passing through the coil mass to those in the working fluid. Aneurysms containing coil masses were sectioned for image analysis to determine surface area fraction and coil uniformity. Results All aneurysms were coiled to a packing density of at least 27%. Packing density, surface area fraction of the dome and neck, and uniformity of the dome were significantly correlated (p<0.05). Hence, multivariate principal components-based partial least squares regression models were used to predict permeability. Similar loading vectors were obtained for packing and uniformity measures. Coil mass permeability was modeled better with the inclusion of packing and uniformity measures of the dome (r2=0.73) than with packing density alone (r2=0.45). The analysis indicates the importance of including a uniformity measure for coil distribution in the dome along with packing measures. Conclusions A densely packed aneurysm with a high degree of coil mass uniformity will reduce permeability. PMID:25031179

  17. Aneurysm permeability following coil embolization: packing density and coil distribution.

    PubMed

    Chueh, Ju-Yu; Vedantham, Srinivasan; Wakhloo, Ajay K; Carniato, Sarena L; Puri, Ajit S; Bzura, Conrad; Coffin, Spencer; Bogdanov, Alexei A; Gounis, Matthew J

    2015-09-01

    Rates of durable aneurysm occlusion following coil embolization vary widely, and a better understanding of coil mass mechanics is desired. The goal of this study is to evaluate the impact of packing density and coil uniformity on aneurysm permeability. Aneurysm models were coiled using either Guglielmi detachable coils or Target coils. The permeability was assessed by taking the ratio of microspheres passing through the coil mass to those in the working fluid. Aneurysms containing coil masses were sectioned for image analysis to determine surface area fraction and coil uniformity. All aneurysms were coiled to a packing density of at least 27%. Packing density, surface area fraction of the dome and neck, and uniformity of the dome were significantly correlated (p<0.05). Hence, multivariate principal components-based partial least squares regression models were used to predict permeability. Similar loading vectors were obtained for packing and uniformity measures. Coil mass permeability was modeled better with the inclusion of packing and uniformity measures of the dome (r(2)=0.73) than with packing density alone (r(2)=0.45). The analysis indicates the importance of including a uniformity measure for coil distribution in the dome along with packing measures. A densely packed aneurysm with a high degree of coil mass uniformity will reduce permeability. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Y stenting assisted coiling using a new low profile visible intraluminal support device for wide necked basilar tip aneurysms: a technical report.

    PubMed

    Conrad, Marcelo D; Brasiliense, Leonardo B C; Richie, Alexa N; Hanel, Ricardo A

    2014-05-01

    Many endovascular techniques have been described in recent years for the management of wide necked aneurysms. The Y stent assisted technique has been generally used for coil embolization of wide necked bifurcation aneurysms. This technique was first described for the treatment of basilar tip aneurysms in combination with several different devices, demonstrating encouraging results. We report the results of the first two cases of wide necked basilar tip aneurysms treated with Y stent assisted coil embolization using a new low profile visible intraluminal stent (LVIS Jr; MicroVention, Tustin, California, USA) delivered through a 0.017 inch microcatheter. We also reviewed the literature comparing other endovascular techniques (coiling alone, stent assisted coiling, and Y stent assisted coiling) for wide necked aneurysms. The LVIS Jr device offers a new option for the treatment of these challenging lesions, with clear advantages over currently available intracranial stents. Larger series and long term results are needed to confirm the applicability and durability of this technique/technology.

  19. Risk Factors to Predict Postoperative Fever After Coil Embolization of Ruptured Intracranial Aneurysms.

    PubMed

    Cai, Kefu; Xu, Tian; Shen, Lihua; Ni, Yaohui; Ji, Qiuhong

    2016-04-01

    To investigate risk factors to predict postoperative fever after endovascular treatment of ruptured intracranial aneurysms. Patients undergoing endovascular coiling to treat subarachnoid hemorrhage in Nantong University between November 2011 and September 2014 were retrospectively reviewed. Postoperative temperature and patient demographic data, admission status, characteristic features of aneurysms, and endovascular coiling procedure were documented and analyzed. There were 336 consecutive patients included in this study, and 111 were classified as febrile (tympanic temperature >38.3°C for at least 2 consecutive days). Univariate analysis demonstrated that age, interval from onset of subarachnoid hemorrhage to operation, history of hypertension and smoking, Hunt and Hess grade, Fisher grade, temperature before coiling, leukocyte count on admission, and infectious complications were correlated with postoperative fever. Five variables were independent risk factors to predict fever by multivariate logistic regression: age >70 years (odds ratio [OR] = 2.6, 95% confidence interval [CI] = 1.2-5.6), Fisher grade 3 or 4 (OR = 2.2, 95% CI = 1.1-4.3), leukocyte count >10,000/mm(3) on admission (OR = 2.3, 95% CI = 1.3-4.0), temperature >37.5°C before coiling (OR = 4.6, 95% CI = 2.0-10.7), and infectious complications (OR = 4.4, 95% CI = 2.2-8.6). Postoperative fever after coil embolization was predicted by changeable and unchangeable risk factors in subarachnoid hemorrhage. However, characteristic features of aneurysms and the coiling procedure had no impact on development of postoperative fever. Preventing any infectious complications, lowering temperature before embolization, and draining bloody cerebrospinal fluid may assist in the prevention of subsequent fever. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Standard Pushable Coils with Fibered Interlock Detachable Coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dudeck, Oliver, E-mail: oliver.dudeck@med.ovgu.de; Bulla, Karsten; Wieners, Gero

    2011-02-15

    The purpose of this study was compare embolization of the gastroduodenal artery (GDA) using standard pushable coils with the Interlock detachable coil (IDC), a novel fibered mechanically detachable long microcoil, in patients scheduled for selective internal radiotherapy (SIRT). Fifty patients (31 male and 19 female; median age 66.6 {+-} 8.1 years) were prospectively randomized for embolization using either standard coils or IDCs. Procedure time, radiation dose, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography were recorded. The procedures differed significantly in time (14:32 {+-} 5:56 min for standard coils vs. 2:13 {+-} 1:04 min formore » IDCs; p < 0.001); radiation dose for coil deployment (2479 {+-} 1237 cGycm Superscript-Two for standard coils vs. 275 {+-} 268 cGycm Superscript-Two for IDCs; p < 0.001); and vessel occlusion (17:18 {+-} 6:39 min for standard coils vs. 11:19 {+-} 7:54 min for IDCs; p = 0.002). A mean of 6.2 {+-} 1.8 coils (n = 27) were used in the standard coil group, and 1.3 {+-} 0.9 coils (p < 0.0001) were used in the IDC group (n = 23) because additional pushable coils were required to achieve GDA occlusion in 4 patients. In 2 patients, the IDC could not be deployed through a Soft-VU catheter. One standard coil dislodged in the hepatic artery and was retrieved. Vessel reperfusion was noted in only 1 patient in the standard coil group. Controlled embolization of the GDA with fibered IDCs was achieved more rapidly than with pushable coils. However, vessel occlusion may not be obtained using a single device only, and the use of sharply angled guiding catheters hampered coil pushability.« less

  1. Embolization of Collateral Vessels Using Mechanically Detachable Coils in Young Children with Congenital Heart Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sato, Y.; Ogino, H.; Hara, M.

    2003-11-15

    Our objective was to evaluate the usefulness of embolizing collateral vessels using mechanically detachable coils (MDCs) in children aged 3 years or younger with congenital heart disease. The subjects were 8 children with congenital heart disease featuring collateral vessels (age 18 days-3 years): 3 with a single ventricle, 2 with the tetralogy of Fallot, 2 with pulmonary atresia, and 1 with a ventricular septal defect. The embolized vessels were the major aortopulmonary collateral artery (MAPCA) in 5 patients, the persistent left superior vena cava in 2, and the coronary arteriovenous fistula in 1. A 4 or a 5 F cathetermore » was used as the guiding device, and embolization was performed using MDCs and other conventional coils introduced through the microcatheter. One patient had growth of new MAPCAs after embolization, and these MAPCAs were also embolized with MDCs. Thus, a total of 9 embolization procedures were performed in 8 patients. Complete occlusion of the collateral vessels was achieved in 8 of 9 procedures (89%). Seven of 8 patients (88%) had uneventful courses after embolization, and MDC procedures appeared to play important roles in avoiding coil migration and achievement of safe coil embolization. One patient who underwent MAPCA embolization showed no improvement in heart function and died 2 months and 19 days later. Embolization of collateral vessels using MDCs in young children with congenital heart disease can be an effective procedure and a valuable adjunct to surgical management.« less

  2. Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka

    Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolizationmore » without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.« less

  3. Time-resolved 3D contrast-enhanced MRA on 3.0T: a non-invasive follow-up technique after stent-assisted coil embolization of the intracranial aneurysm.

    PubMed

    Choi, Jin Woo; Roh, Hong Gee; Moon, Won-Jin; Kim, Na Ra; Moon, Sung Gyu; Kang, Chung Hwan; Chun, Young Il; Kang, Hyun-Seung

    2011-01-01

    To evaluate the usefulness of time-resolved contrast enhanced magnetic resonance angiography (4D MRA) after stent-assisted coil embolization by comparing it with time of flight (TOF)-MRA. TOF-MRA and 4D MRA were obtained by 3T MRI in 26 patients treated with stent-assisted coil embolization (Enterprise:Neuroform = 7:19). The qualities of the MRA were rated on a graded scale of 0 to 4. We classified completeness of endovascular treatment into three categories. The degree of quality of visualization of the stented artery was compared between TOF and 4D MRA by the Wilcoxon signed rank test. We used the Mann-Whitney U test for comparing the quality of the visualization of the stented artery according to the stent type in each MRA method. The quality in terms of the visualization of the stented arteries in 4D MRA was significantly superior to that in 3D TOF-MRA, regardless of type of the stent (p < 0.001). The quality of the arteries which were stented with Neuroform was superior to that of the arteries stented with Enterprise in 3D TOF (p < 0.001) and 4D MRA (p = 0.008), respectively. 4D MRA provides a higher quality view of the stented parent arteries when compared with TOF.

  4. Dual microcather-dual detachable coil technique in embolization for a congenital intrahepatic portosystemic venous shunt (IPSVS).

    PubMed

    Suzuki, Kazushi; Shimohira, Masashi; Hashizume, Takuya; Suzuki, Yosuke; Shibamoto, Yuta

    2013-09-01

    We report a 14-year-old boy with a large intrahepatic portosystemic venous shunt. The shunt seemed to be difficult to coil embolize because it was so large and short. However, it was successfully treated by coil embolization with a new dual microcatheter-dual detachable coil technique.

  5. Initial experience of a novel sheath guide for transbrachial coil embolization of cerebral aneurysms in the anterior cerebral circulation.

    PubMed

    Iwata, Tomonori; Mori, Takahisa; Tajiri, Hiroyuki; Miyazaki, Yuichi; Nakazaki, Masahito; Mizokami, Koji

    2013-03-01

    The transfemoral approach is a common technique for coil embolization of cerebral aneurysms in the anterior cerebral circulation. However, it is difficult to advance a guiding catheter into the carotid artery via the femoral route in patients with a tortuous aortic arch, an unfavorable supra-aortic takeoff, aortic diseases, or occlusion of the femoral artery. To report our initial experiences of coil embolization of cerebral aneurysms in the anterior cerebral circulation with a novel sheath guide for transbrachial carotid cannulation. A sheath guide designed specifically for transbrachial carotid cannulation was developed; transbrachial coil embolization for cerebral aneurysms began in May 2011. Included for analysis were patients who underwent transbrachial coil embolization for cerebral aneurysms in the anterior cerebral circulation from May 2011 to January 2012. Adjuvant techniques, angiographic results, procedural success, and periprocedural complications were investigated. Ten patients underwent transbrachial coil embolization of cerebral aneurysms in the anterior cerebral circulation. All procedures were successful using the brachial route. No periprocedural complications occurred. Patients were permitted to get seated immediately after coil embolization even during hemostasis. The sheath guide specifically designed for transbrachial carotid cannulation was useful for coil embolization of cerebral aneurysms in the anterior cerebral circulation.

  6. Minimizing bleeding complications in spinal tumor surgery with preoperative Onyx embolization via dual-lumen balloon catheter.

    PubMed

    Ladner, Travis R; He, Lucy; Lakomkin, Nikita; Davis, Brandon J; Cheng, Joseph S; Devin, Clinton J; Mocco, J

    2016-02-01

    Intraoperative bleeding is a significant risk in surgery for highly vascular spinal tumors, but preoperative embolization can safely decrease intraoperative blood loss in extrinsic spine tumors. Onyx, widely used for cerebrovascular embolization, has been increasingly used as an embolic agent for preoperative spinal tumor embolization. The Scepter catheter, a dual-lumen balloon catheter, may improve tumor parenchymal penetration without the danger and limitations of significant embolic reflux. This may reduce bleeding risk during spinal surgery. Eleven consecutive cases of preoperative Onyx embolization of extrinsic spinal tumors were identified, all of whom had subsequent spinal surgery. Demographic data and clinical variables were collected. Patients were divided into Scepter (n=6) and non-Scepter (n=5) groups. The Mann-Whitney U test was used to compare continuous outcome variables and the Fisher exact test was used to compare categorical variables. Estimated blood loss in the Scepter group was significantly lower than in the non-Scepter group (584±124 vs 2400±738 mL, p=0.004). The volume of intraoperative transfusion was also significantly lower (1.2±0.4 vs 5.8±1.7 units, p=0.004). There was no significant difference in the number of vessels embolized, vials of Onyx used, use of coiling adjunct, contrast load, radiation dose, or fluoroscopy time per pedicle (p>0.05). The addition of the Scepter catheter to preoperative Onyx embolization is safe and feasible. In this small series, the Scepter catheter was associated with a reduction of intraoperative bleeding by 76% and a 79% lower transfusion volume. This was not accompanied by any unwanted increase in vials of Onyx used, contrast load, radiation dose, or fluoroscopy time. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Endovascular Treatment of Cerebral Aneurysm with Coils and Onyx

    PubMed Central

    Ueno, J.; Tohma, N.

    2004-01-01

    Summary We investigated endovascular treatment of cerebral aneurysm by coil and Onyx in vivo experiment in order to promote the advantages of coil embolization,. The aim of this study was to clarify the advantages and problems of coil and Onyx embolization and to evaluate its potentials for application in clinical medicine. We set experimental aneurysms made of external jugular vein to bilateral carotid arteries of 10 Beagle dogs and embolized aneurysm with coils and Onyx. Two months later, the dogs were sacrificed and took out the experimental aneurysms and examined them histologically. We have experienced Onyx migration into the vessel at the beginning of our experiment. Technical problems were as follows; Onyx was not easily visible on DSA monitor particularly in tight coil packing. Catheter tip was often stuck to the Onyx in the aneurysm. Protect balloon could not completely protect the Onyx leakage into the vessel. Microscopic examinations were as follows; The aneurysm was filled with Onyx, coils, and inflammatory reactants. The orifice of the aneurysm was packed with augmented fibrous tissue. 1. This method increased contact between the aneurysm wall and coils. 2. Onyx filled the intra-aneurismal space more tightly. 3. Coils prevented Onyx from flowing out into the vessel. 4. In Onyx, intimal layer was more rapidly formed at the neck of the aneurysm than coils only. 5. The most important problems during Onyx embolization is how to prevent Onyx migration into the vessel. We should like to propose the guideline for Onyx embolization. PMID:20587272

  8. Embolization of a High-Output Postnephrectomy Aortocaval Fistula with Gianturco Coils and Cyanoacrylate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cekirge, Saruhan; Oguzkurt, Levent; Saatci, Isil

    1996-11-15

    The authors describe the endovascular treatment of a high-output, large-caliber, postnephrectomy aortocaval fistula using a mixture of cyanoacrylate and lipiodol combined with Gianturco coil embolization. Thirty-nine coils were used to decrease the flow through the fistula so that a fast-polymerizing glue mixture could be injected into the fistula. During rapid polymerization, the N-butyl-2-cyanoacrylate (NBCA) mixture was trapped within the coils, providing an easily controllable glue cast in the fistula, thereby preventing inadvertent embolization into the lungs. This approach can be of considerable benefit for the endovascular treatment of central high-output fistulas.

  9. Onyx, a New Liquid Embolic Material for Peripheral Interventions: Preliminary Experience in Aneurysm, Pseudoaneurysm, and Pulmonary Arteriovenous Malformation Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vanninen, Ritva L., E-mail: ritva.vanninen@kuh.fi; Manninen, I.

    Purpose. To describe our preliminary experience with a new liquid embolization agent, Onyx, in peripheral interventions. Methods and results. We successfully treated two peripheral aneurysms (one in an internal iliac artery, one in a thoracic collateral artery of an aortic coarctation), two peripheral pseudoaneurysms (one in a lumbar artery, one in a renal artery), and one pulmonary arteriovenous malformation. Conclusion. Onyx is a promising alternative embolic material for peripheral interventions. It can be combined with coils in selected cases, and balloon catheters can be effectively used during slow injection of embolic material to control flow and protect the aneurysm neck.

  10. Follow-Up of 58 Traumatic Carotid-Cavernous Fistulas after Endovascular Detachable-Balloon Embolization at a Single Center

    PubMed Central

    Xu, Xiao-Quan; Liu, Sheng; Zu, Qing-Quan; Zhao, Lin-Bo; Xia, Jin-Guo; Zhou, Chun-Gao; Zhou, Wei-Zhong

    2013-01-01

    Background and Purpose This study evaluated the clinical value of detachable-balloon embolization for traumatic carotid-cavernous fistula (TCCF), focusing on the frequency, risk factors, and retreatment of recurrence. Methods Fifty-eight patients with TCCF underwent transarterial detachable-balloon embolization between October 2004 and March 2011. The clinical follow-up was performed every 3 months until up to 3 years postprocedure. Each patient was placed in either the recurrence group or the nonrecurrence group according to whether a recurrence developed after the first procedure. The relevant factors including gender, fistula location, interval between trauma and the interventional procedure, blood flow in the carotid-cavernous fistula, number of balloons, and whether the internal carotid artery (ICA) was sacrificed were evaluated. Results All 58 TCCFs were successfully treated with transarterial balloon embolization, including 7 patients with ICA sacrifice. Recurrent fistulas occurred in seven patients during the follow-up period. Univariate analysis indicated that the interval between trauma and the interventional procedure (p=0.006) might be the main factor related to the recurrence of TCCF. The second treatments involved ICA sacrifice in two patients, fistula embolization with balloons in four patients, and placement of a covered stent in one patient. Conclusions Detachable balloons can still serve as the first-line treatment for TCCFs and recurrent TCCFs despite having a nonnegligible recurrence rate. Shortening the interval between trauma and the interventional procedure may reduce the risk of recurrence. PMID:23626645

  11. Onyx HD-500 embolization of intracranial aneurysms: modified technique using continuous balloon inflation under conscious sedation.

    PubMed

    Rahme, Ralph; Grande, Andrew; Jimenez, Lincoln; Abruzzo, Todd A; Ringer, Andrew J

    2014-08-01

    The conventional technique of intracranial aneurysm embolization using Onyx HD-500 (ev3 Neurovascular, Irvine, CA, USA) involves repetitive balloon inflation-deflation cycles under general anesthesia. By limiting parent artery occlusion to 5 minutes, this cyclic technique is thought to minimize cerebral ischemia. However, intermittent balloon deflation may lengthen procedure time and allow balloon migration, resulting in intimal injury or Onyx leakage. We report our experience using a modified technique of uninterrupted Onyx injection with continuous balloon occlusion under conscious sedation. All Onyx embolization procedures for unruptured aneurysms performed by the senior author (A.J.R.) between September 2008 and April 2010 were retrospectively reviewed. Demographic, clinical, angiographic, and procedural data were recorded. Twenty-four embolization procedures were performed in 21 patients with 23 aneurysms, including four recurrences. Twenty aneurysms (87%) involved the paraclinoid or proximal supraclinoid internal carotid artery. Size ranged from 2.5 to 24mm and neck diameter from 2 to 8mm. The modified technique was employed in 19 cases. All but one patient (94.4%) tolerated continuous balloon inflation. Complete occlusion was achieved in 20 aneurysms (83.3%) and subtotal occlusion in three (12.5%). Stable angiographic results were seen in 85%, 94%, 94%, and 100% of patients at 6, 12, 24, and 36months, respectively. There were no deaths. Permanent non-disabling neurological morbidity occurred in one patient (4.2%). Minor, transient, and/or angiographic complications were seen in three patients (12.5%), none related to the technique itself. Onyx embolization of unruptured intracranial aneurysms can be safely and effectively performed using continuous balloon inflation under conscious sedation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Closure of a giant saphenous vein graft aneurysm with embolization coil.

    PubMed

    Kumar, Ashwani; Santana, Dixon; Jenkins, Leigh Ann

    2009-01-01

    Aneurysms of saphenous vein grafts (SVGs) to coronary arteries are rare, usually asymptomatic and found incidentally. We report a case of an 84-year-old female who was found to have 8.1 x 8.4 cm aneurysm of an SVG to obtuse marginal (OM) artery. The aneurysm was prior to the distal anastamosis but no flow into the OM artery was noted. Cook Tornado Embolization Coils were used successfully to occlude the SVG proximal to the aneurysm. No complications occurred. The use of embolization coils is an effective and safe method for aneurysm occlusion when the anatomy is suitable and especially when patient is high risk for repeat surgical intervention.

  13. Effect of electromagnetic radiation on the coils used in aneurysm embolization.

    PubMed

    Lv, Xianli; Wu, Zhongxue; Li, Youxiang

    2014-06-01

    This study evaluated the effects of electromagnetic radiation in our daily lives on the coils used in aneurysm embolization. Faraday's electromagnetic induction principle was applied to analyze the effects of electromagnetic radiation on the coils used in aneurysm embolization. To induce a current of 0.5mA in less than 5 mm platinum coils required to stimulate peripheral nerves, the minimum magnetic field will be 0.86 μT. To induce a current of 0.5 mA in platinum coils by a hair dryer, the minimum aneurysm radius is 2.5 mm (5 mm aneurysm). To induce a current of 0.5 mA in platinum coils by a computer or TV, the minimum aneurysm radius is 8.6 mm (approximate 17 mm aneurysm). The minimum magnetic field is much larger than the flux densities produced by computer and TV, while the minimum aneurysm radius is much larger than most aneurysm sizes to levels produced by computer and TV. At present, the effects of electromagnetic radiation in our daily lives on intracranial coils do not produce a harmful reaction. Patients with coiled aneurysm are advised to avoid using hair dryers. This theory needs to be proved by further detailed complex investigations. Doctors should give patients additional instructions before the procedure, depending on this study.

  14. Effect of Electromagnetic Radiation on the Coils Used in Aneurysm Embolization

    PubMed Central

    Lv, Xianli; Wu, Zhongxue; Li, Youxiang

    2014-01-01

    Summary This study evaluated the effects of electromagnetic radiation in our daily lives on the coils used in aneurysm embolization. Faraday’s electromagnetic induction principle was applied to analyze the effects of electromagnetic radiation on the coils used in aneurysm embolization. To induce a current of 0.5mA in less than 5 mm platinum coils required to stimulate peripheral nerves, the minimum magnetic field will be 0.86 μT. To induce a current of 0.5 mA in platinum coils by a hair dryer, the minimum aneurysm radius is 2.5 mm (5 mm aneurysm). To induce a current of 0.5 mA in platinum coils by a computer or TV, the minimum aneurysm radius is 8.6 mm (approximate 17 mm aneurysm). The minimum magnetic field is much larger than the flux densities produced by computer and TV, while the minimum aneurysm radius is much larger than most aneurysm sizes to levels produced by computer and TV. At present, the effects of electromagnetic radiation in our daily lives on intracranial coils do not produce a harmful reaction. Patients with coiled aneurysm are advised to avoid using hair dryers. This theory needs to be proved by further detailed complex investigations. Doctors should give patients additional instructions before the procedure, depending on this study. PMID:24976203

  15. Transcatheter arterial embolization--major complications and their prevention.

    PubMed

    Miller, F J; Mineau, D E

    1983-01-01

    A thorough account is given of the complications of embolization techniques in nonneurovascular areas, including hepatic infarction, renal and splenic abscess formation. Infarction of the urinary bladder, gallbladder, stomach, and bowel are discussed. Suggestions are offered to prevent complications from embolization where possible. Specific agents for embolization are detailed and their relative merits are compared; ethyl alcohol has recently gained popularity for treating esophageal varices and infarcting renal tumors. Care is advocated when using alcohol in the renal arteries; employing this agent is currently contraindicated in the celiac and mesenteric arteries. Coils and balloon systems are also described along with their potential complications.

  16. Closure of a Giant Saphenous Vein Graft Aneurysm with Embolization Coil

    PubMed Central

    Kumar, Ashwani; Santana, Dixon; Jenkins, Leigh Ann

    2009-01-01

    Aneurysms of saphenous vein grafts (SVGs) to coronary arteries are rare, usually asymptomatic and found incidentally. We report a case of an 84-year-old female who was found to have 8.1 × 8.4 cm aneurysm of an SVG to obtuse marginal (OM) artery. The aneurysm was prior to the distal anastamosis but no flow into the OM artery was noted. Cook Tornado Embolization Coils were used successfully to occlude the SVG proximal to the aneurysm. No complications occurred. The use of embolization coils is an effective and safe method for aneurysm occlusion when the anatomy is suitable and especially when patient is high risk for repeat surgical intervention. PMID:19946632

  17. In vitro simulator with numerical stress analysis for evaluation of stent-assisted coiling embolization in cerebral aneurysm treatments.

    PubMed

    Shi, Chaoyang; Kojima, Masahiro; Tercero, Carlos; Najdovski, Zoran; Ikeda, Seiichi; Fukuda, Toshio; Arai, Fumihito; Negoro, Makoto

    2014-12-01

    There are several complications associated with Stent-assisted Coil Embolization (SACE) in cerebral aneurysm treatments, due to damaging operations by surgeons and undesirable mechanical properties of stents. Therefore, it is necessary to develop an in vitro simulator that provides both training and research for evaluating the mechanical properties of stents. A new in vitro simulator for three-dimensional digital subtraction angiography was constructed, followed by aneurysm models fabricated with new materials. Next, this platform was used to provide training and to conduct photoelastic stress analysis to evaluate the SACE technique. The average interaction stress increasingly varied for the two different stents. Improvements for the Maximum-Likelihood Expectation-Maximization method were developed to reconstruct cross-sections with both thickness and stress information. The technique presented can improve a surgeon's skills and quantify the performance of stents to improve mechanical design and classification. This method can contribute to three-dimensional stress and volume variation evaluation and assess a surgeon's skills. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Temporary subclavian steal to reduce intraprocedural embolic risk during detachable balloon occlusion of vertebrobasilar aneurysms: technical note with two case reports.

    PubMed

    Eckard, D A; O'Boynick, P L; Han, P P

    1996-11-01

    Unintentional intracerebral embolization is a serious, ever present threat during neurointerventional procedures. We have devised a method to reduce this intraprocedural risk in vertebral artery interventions by creating a temporary subclavian steal. For this technique, a temporary balloon occlusion catheter is advanced into the proximal subclavian artery via a femoral artery approach, while a second introducer catheter is passed into the target vertebral artery via an axillary artery access. The temporary occluding balloon is then inflated within the proximal subclavian artery, establishing a subclavian steal that diverts blood flow into the arm. Permanent balloon occlusion of the vertebral artery can then be accomplished without fear of intracerebral embolization. Two patients with vertebrobasilar junction aneurysms were successfully treated with detachable balloon embolization using this cerebral protection technique. The permanent occlusion balloons were easily passed through the introducer catheter without difficulty despite reversed vertebral artery flow. No complications were encountered, and the aneurysms were successfully occluded in both patients. Temporary subclavian steal can be easily created to reduce the risk of cerebral embolic complications when performing interventional neuroradiological procedures in the vertebral artery.

  19. Peri-stent aneurysm formation following a stent implant for stenotic intracranial vertebral artery dissection: a technical report of two cases successfully treated with coil embolization.

    PubMed

    Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro

    2013-02-01

    Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.

  20. Temporary Percutaneous Aortic Balloon Occlusion to Enhance Fluid Resuscitation Prior to Definitive Embolization of Post-Traumatic Liver Hemorrhage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsuoka, Shin; Uchiyama, Katsuhiro; Shima, Hideki

    2001-07-15

    We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source.

  1. Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia.

    PubMed

    Tau, Noam; Atar, Eliyahu; Mei-Zahav, Meir; Bachar, Gil N; Dagan, Tamir; Birk, Einat; Bruckheimer, Elchanan

    2016-08-01

    Coil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia. The study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004-2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher's exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05. 16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4-18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413). The use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

  2. The Influence of Dome Size, Parent Vessel Angle, and Coil Packing Density on Coil Embolization Treatment in Cerebral Aneurysms

    NASA Astrophysics Data System (ADS)

    Frakes, David H.; Indahlastari, Aprinda; Ryan, Justin; Babiker, M. Haithem; Nair, Priya; Parthas, Varsha

    2013-11-01

    Intracranial aneurysms (ICAs) are dilated cerebral blood vessels. Treating ICAs effectively prior rupture is crucial since their association with 45% mortality rate. Embolic coiling is the most effective ICA treatment. Series of embolic coils are deployed into the aneurysm with the intent of reaching a sufficient packing density (PD) to help seal off the ICA from circulation. While coiling is effective, treatment failures have been associated with basilar tip aneurysms (BTAs), perhaps because of their geometry. The aim of this study was to examine the effect of dome size, parent vessel (PV) angle, and PD on intraaneurysmal (IA) velocity, crossneck (CN) flow and low wall shear stress (WSS) area using simulations and experiments in idealized BTA models. IA velocity and CN flow decreased after coiling, while low WSS area increased. With increasing PD, IA velocity and CN flow were further reduced, but low WSS area had a minimal change. Coil PD had the greatest impact on post-treatment flow while dome size had a greater impact than PV angle. Overall, the role of aneurysmal geometries may vary depending on treatment goal and timing e.g., high coil PD may reduce IA velocity more effectively during early aneurysmal growth when the dome size is small. Funded by the American Heart Association.

  3. Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tau, Noam, E-mail: taunoam@gmail.com; Atar, Eliyahu; Mei-Zahav, Meir

    PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both),more » and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.« less

  4. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morshedi, Maud M., E-mail: maud.morshedi@my.rfums.org; Bauman, Michael, E-mail: mbauman@ucsd.edu; Rose, Steven C., E-mail: scrose@ucsd.edu

    2015-04-15

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose,more » radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.« less

  5. Stand-alone coil embolization of anterior communicating artery aneurysms: Efficacy and technical issues.

    PubMed

    Kocur, Damian; Zbroszczyk, Miłosz; Przybyłko, Nikodem; Hofman, Mariusz; Jamróz, Tomasz; Baron, Jan; Bażowski, Piotr; Kwiek, Stanisław

    2016-10-01

    We report our experience with endovascular coiling of anterior communicating artery aneurysms with special consideration of angiographic and clinical outcomes and periprocedural complications. The analysis included treatment results of 28 patients with ruptured and unruptured aneurysms. The aneurysm size ranged from 1.8 to 9.8 mm (mean 5.2, SD 1.7). Clinical examinations with the use of modified Rankin Score and angiographic outcomes were evaluated initially post-embolization and at a minimum follow-up of six months. Initial post-treatment complete and near-complete aneurysm occlusion was achieved in 27 (96%) cases and incomplete occlusion in one (4%) case. Imaging follow-up, performed in 15 (53.6%) patients, showed no change in the degree of occlusion in 11 (73%), coil compaction in one (7%) and progressive occlusion in three (20%) patients. Three (20%) patients underwent a second coil embolization. The procedure-related severe morbidity and mortality rate was 6.4% (2/31). Coil prolapse was present in one (3.2%) case and intraprocedural aneurysm rupture in three (9.6%) cases. The clinical follow-up evaluation achieved in 19 (67.9%) patients showed no change in 17 (89.5%) patients and improvement in two (10.5%) patients. Although the efficacy of coil embolization of anterior communicating artery aneurysms is unquestionable and the procedure-related complications are acceptable, they should not be neglected. Further investigations are needed to better understand protective factors, as well as to establish unequivocally appropriate management strategy of these complications. © The Author(s) 2016.

  6. Stand-alone coil embolization of anterior communicating artery aneurysms: Efficacy and technical issues

    PubMed Central

    Zbroszczyk, Miłosz; Przybyłko, Nikodem; Hofman, Mariusz; Jamróz, Tomasz; Baron, Jan; Bażowski, Piotr; Kwiek, Stanisław

    2016-01-01

    Objective We report our experience with endovascular coiling of anterior communicating artery aneurysms with special consideration of angiographic and clinical outcomes and periprocedural complications. Materials and methods The analysis included treatment results of 28 patients with ruptured and unruptured aneurysms. The aneurysm size ranged from 1.8 to 9.8 mm (mean 5.2, SD 1.7). Clinical examinations with the use of modified Rankin Score and angiographic outcomes were evaluated initially post-embolization and at a minimum follow-up of six months. Results Initial post-treatment complete and near-complete aneurysm occlusion was achieved in 27 (96%) cases and incomplete occlusion in one (4%) case. Imaging follow-up, performed in 15 (53.6%) patients, showed no change in the degree of occlusion in 11 (73%), coil compaction in one (7%) and progressive occlusion in three (20%) patients. Three (20%) patients underwent a second coil embolization. The procedure-related severe morbidity and mortality rate was 6.4% (2/31). Coil prolapse was present in one (3.2%) case and intraprocedural aneurysm rupture in three (9.6%) cases. The clinical follow-up evaluation achieved in 19 (67.9%) patients showed no change in 17 (89.5%) patients and improvement in two (10.5%) patients. Conclusions Although the efficacy of coil embolization of anterior communicating artery aneurysms is unquestionable and the procedure-related complications are acceptable, they should not be neglected. Further investigations are needed to better understand protective factors, as well as to establish unequivocally appropriate management strategy of these complications. PMID:27531863

  7. Ischemic Stroke After Treatment of Intraprocedural Thrombosis During Stent-Assisted Coiling and Flow Diversion.

    PubMed

    Adeeb, Nimer; Griessenauer, Christoph J; Moore, Justin M; Foreman, Paul M; Shallwani, Hussain; Motiei-Langroudi, Rouzbeh; Gupta, Raghav; Baccin, Carlos E; Alturki, Abdulrahman; Harrigan, Mark R; Siddiqui, Adnan H; Levy, Elad I; Ogilvy, Christopher S; Thomas, Ajith J

    2017-04-01

    Intraprocedural thrombosis poses a formidable challenge during neuroendovascular procedures because the risks of aggressive thromboembolic treatment must be balanced against the risk of postprocedural hemorrhage. The aim of this study was to identify predictors of ischemic stroke after intraprocedural thrombosis after stent-assisted coiling and pipeline embolization device placement. A retrospective analysis of intracranial aneurysms treated with stent-assisted coiling or pipeline embolization device placement between 2007 and 2016 at 4 major academic institutions was performed to identify procedures that were complicated by intraprocedural thrombosis. Intraprocedural thrombosis occurred in 34 (4.6%) procedures. Postprocedural ischemic stroke and hemorrhage occurred in 20.6% (7/34) and 11.8% (4/34) of procedures complicated by intraprocedural thrombosis, respectively. Current smoking was an independent predictor of ischemic stroke. There was no statistically significant difference in the rate of ischemic stroke or postprocedural hemorrhage with the use of abciximab compared with the use of eptifibatide in treatment of intraprocedural thrombosis. Current protocols for treatment of intraprocedural thrombosis associated with placement of intra-arterial devices were effective in preventing ischemic stroke in ≈80% of cases. Current smoking was the only independent predictor of ischemic stroke. © 2017 American Heart Association, Inc.

  8. Splenic Artery Embolization in Blunt Trauma: A Single-Center Retrospective Comparison of the Use of Gelatin Sponge Versus Coils.

    PubMed

    Rasuli, Pasteur; Moosavi, Bardia; French, Gordon J; Petrcich, William; Hammond, Ian

    2017-12-01

    The purpose of this study was to compare the efficacy of gelatin sponge with that of coils for splenic artery embolization in the treatment of blunt splenic injury. A single-center retrospective review was performed with the records of 63 patients (45 men, 18 women; mean age, 45.5 years; range, 16-84 years) with blunt splenic injury treated at a tertiary care trauma center by splenic artery embolization with gelatin sponge (n = 30 patients) or metallic coils (n = 33 patients) between 2005 and 2014. The two groups had comparable median American Association for the Surgery of Trauma grades of IV and comparable angiographic appearances regarding active extravasation and pseudoaneurysm formation at preembolization splenic arteriography (p = 0.32). Clinical outcomes and procedure-related outcomes were evaluated. The success rates were similar in the two groups: splenic artery embolization failed in 6.6% (2/30) of patients in the gelatin sponge group and 12.1% (4/33) in the coil embolization group (p = 0.45; 95% CI, -30.1% to 19.2%). Major complications occurred in six patients (20.0%) in the gelatin sponge group and in six patients (18.1%) in the coil group (p = 0.85; 95% CI, -23.0% to 26.6%). Minor complications occurred in three patients (10.0%) in the gelatin sponge group and seven patients (21.2%) in the coil group (p = 0.21; 95% CI, -35.4% to 14.0%). Procedure time was significantly shorter in the gelatin sponge group (median, 32 minutes; interquartile range, 18-48 minutes) than in the coil group (median, 53 minutes; interquartile range, 30-76 minutes) (p = 0.01). Splenic artery embolization with gelatin sponge appears to be as effective and as safe as coil embolization and can be completed in a shorter time.

  9. Stent-assisted embolization of wide-neck anterior communicating artery aneurysms: Review of consecutive 34 cases.

    PubMed

    Kocur, Damian; Zbroszczyk, Miłosz; Przybyłko, Nikodem; Hofman, Mariusz; Jamróz, Tomasz; Baron, Jan; Bażowski, Piotr; Kwiek, Stanisław

    We report our experience with stent-assisted coiling of anterior communicating artery aneurysms with special consideration of angiographic and clinical outcomes, retreatment rate and periprocedural complications. The analysis included 34 consecutive ruptured and unruptured wide-neck aneurysms. The aneurysm size ranged from 2 to 18mm (mean 5.47). Clinical examinations with the use of modified Rankin Score and angiographic outcomes were evaluated initially post-embolization and at a minimum follow-up of 6 months. Initial post-treatment complete and near-complete aneurysm occlusion was achieved in 32 (94%) and 2 (6%) cases, respectively. Imaging follow-up, performed in 28 (82%) patients, showed no change in the degree of occlusion in 25 (89%) cases and coil compaction in 3 (11%) patients. Of these, one (3.6%) patient underwent a second coil embolization. The periprocedural severe complication rate was 2.9% (1/35) and was associated with prolonged attempt of retrieval of migrated coil resulting in anterior cerebral artery infarct with serious clinical consequences. In another 3 patients periprocedural adverse events without delayed clinical consequences were noticed. The clinical follow-up evaluation achieved in 33 (97%) patients showed no change in 30 (91%) cases, one patient (3%) with clinical improvement and two (6%) cases of neurological deterioration. The use of stent is feasible and effective for coil embolization of wide-necked anterior communicating artery aneurysms. Although periprocedural complications resulting in severe morbidity are rare, they should be noted, since in terms of thromboembolic events some of them presumably have a potential to be avoidable. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  10. Post-Mortem Pathological Examination of Two Patients after Intraaneurysmal Embolization Using Guglielmi Detachable Coils

    PubMed Central

    Nakahara, T.; Sakamoto, S.; Hamasaki, O.; Sakoda, K.

    2003-01-01

    Summary We report the histological findings in two patients treated using Guglielmi detachable coils with almost complete occlusion of the aneurysms. Autopsies of these patients were performed one week and one year after GDC embolization respectively. In one aneurysm that was obtained at autopsy one week after embolization, the histological findings revealed coils and an unorganized thrombus-filled aneurysm sac; an incomplete cell-lining on the luminal side of fibrin thrombi in the region of the neck of the aneurysm was recognized. In the other aneurysm in which autopsy was performed one year after embolization, an organized fibrous tissue at the margin of the aneurysmal wall and vascular granulation tissue at the center of the aneurysm were observed. There is a single layer of endothelium covering fibrous tissue in the neck of the aneurysm. We discuss the healing process after GDC treatment. PMID:20591231

  11. PERCUTANEOUS RADIOFREQUENCY ASSISTED LIVER PARTITION WITH PORTAL VEIN EMBOLIZATION FOR STAGED HEPATECTOMY (PRALPPS).

    PubMed

    Giménez, Mariano E; Houghton, Eduardo J; Davrieux, C Federico; Serra, Edgardo; Pessaux, Patrick; Palermo, Mariano; Acquafresca, Pablo A; Finger, Caetano; Dallemagne, Bernard; Marescaux, Jacques

    2018-03-01

    When a major hepatic resection is necessary, sometimes the future liver remnant is not enough to maintain sufficient liver function and patients are more likely to develop liver failure after surgery. To test the hypothesis that performing a percutaneous radiofrecuency liver partition plus percutaneous portal vein embolization (PRALPPS) for stage hepatectomy in pigs is feasible. Four pigs (Sus scrofa domesticus) both sexes with weights between 25 to 35 kg underwent percutaneous portal vein embolization with coils of the left portal vein. By contrasted CT, the difference between the liver parenchyma corresponding to the embolized zone and the normal one was identified. Immediately, using the fusion of images between ultrasound and CT as a guide, radiofrequency needles were placed percutaneouslyand then ablated until the liver partition was complete. Finally, hepatectomy was completed with a laparoscopic approach. All animals have survived the procedures, with no reported complications. The successful portal embolization process was confirmed both by portography and CT. In the macroscopic analysis of the pieces, the depth of the ablation was analyzed. The hepatic hilum was respected. On the other hand, the correct position of the embolization material on the left portal vein could be also observed. "Percutaneous radiofrequency assisted liver partition with portal vein embolization" (PRALLPS) is a feasible procedure.

  12. Healing of Saccular Aneurysms Following Platinum Coil Embolization: Lack of Improved Efficacy with Vitamin C Supplementation

    PubMed Central

    Dai, Daying; Ding, Yong-Hong; Rezek, Issa; Lewis, Debra A.; Kallmes, David F.; Kadirvel, Ramanathan

    2013-01-01

    BACKGROUND AND PURPOSE To test the hypothesis that systemic administration of vitamin C, through its action of stimulating collagen synthesis and cross-linking, would decrease the recurrence and improve the occlusion experimental aneurysms treated with platinum coil embolization. METHODS Nineteen experimental aneurysms in female rabbits were embolized with platinum coils (>30% packing density). The animals were divided into three groups: Group 1 (n=6) rabbits served as controls, Group 2 (n=5) rabbits were fed with a vitamin C-supplemented feed and Group 3 (n=8) rabbits were medicated with vitamin C pills. Digital subtraction angiography was used to evaluate stability after embolization. Subjects were euthanized at 12 weeks after coil implantation, and serum vitamin C levels were then measured. Histological samples were examined with a grading system (range, 0-12) based on the neck and dome features. Masson Trichrome staining was employed to evaluate collagen deposition. Parametric data were analyzed with one-way analysis of variance and non-parametric data were examined using a Kruskal-Wallis test. RESULTS There were no significant differences between groups in mean aneurysm size. Mean serum vitamin C concentration was significantly higher in Group 3 and Group 2 compared to Group 1, while vitamin C levels between Group 2 and Group 3 were statistically comparable. Coil compaction was noted in one of six subjects in Group 1 and three of eight subjects in Group 3. All the remaining aneurysms in the test and control groups showed stable occlusion. There were no significant differences in histological scores or collagen deposition among groups. CONCLUSION Vitamin C supplementation following platinum coil embolization does not demonstrate improvement of long-term occlusion rates of aneurysms. PMID:22914744

  13. Jailed double-microcatheter technique following horizontal stenting for coil embolization of intracranial wide-necked bifurcation aneurysms: A technical report of two cases.

    PubMed

    Kitahara, Takahiro; Hatano, Taketo; Hayase, Makoto; Hattori, Etsuko; Miyakoshi, Akinori; Nakamura, Takehiko

    2017-04-01

    The horizontal stenting technique facilitates endovascular treatment of wide-necked bifurcation intracranial aneurysms. Previous literature shows, however, that subsequent coil embolization at initial treatment results in incomplete obliteration in many cases. The authors present two consecutive cases of wide-necked large bifurcation aneurysms to describe an additional coil embolization technique following horizontal stenting. The patients were a 53-year-old female with an unruptured internal carotid artery terminus aneurysm and a 57-year-old female with a recurrent basilar artery tip aneurysm. Both patients underwent endovascular treatment with horizontal stenting followed by coil embolization with jailed double-microcatheters. Immediate complete obliteration was achieved with no complications, and no recanalization was observed at the one-year follow-up in both cases. Coil embolization with jailed double-microcatheter technique following horizontal stenting is a safe and effective strategy for wide-necked bifurcation aneurysms.

  14. Congenital Aorto-azygous Fistula Treated with Coil Embolization: Case Report and Review of the Literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romero, Francisco Diaz; Fernandez, Eudaldo M. Lopez-Tomassetti; Albelo, Tomas Perez

    2006-10-15

    Arteriovenous fistulas between the aorta and the azygous vein usually manifest as a continuous audible murmur mimicking a patent ductus arteriosus when observed at birth. Symptoms when present during childhood are related to dyspnea or cardiac insufficiency. Embolotherapy of congenital vascular malformations is possible. However when this less invasive treatment fails, surgical treatment is sometimes necessary. We describe the case of a 12-year-old child with a large thoracic arteriovenous fistula between the descending thoracic aorta and the azygous vein, which was closed successfully by coil embolization. Available data in the literature suggest that coil embolization of aorto-azygous fistulas is usuallymore » successful.« less

  15. Double-lumen balloon for Onyx® embolization via extracranial arteries in transverse sigmoid dural arteriovenous fistulas: initial experience.

    PubMed

    Clarençon, Frédéric; Di Maria, Federico; Gabrieli, Joseph; Carpentier, Alexandre; Pistochi, Silvia; Bartolini, Bruno; Zeghal, Chiheb; Chiras, Jacques; Sourour, Nader-Antoine

    2016-10-01

    Transverse-sigmoid dural arteriovenous fistulas (TS DAVFs) can be challenging to treat by endovascular means. Indeed, a total cure of the fistula can only be achieved when complete occlusion of the fistulous point(s) is obtained by penetration of the embolic agent. However, in some cases, especially for transosseous branches from extracranial arteries like the occipital artery (OcA) or the superficial temporal artery (STA), such penetration is usually poor, leading to major proximal reflux and incomplete fistula obliteration. We present three cases of embolization in two patients with TS DAVF through the OcA and/or the STA with Onyx® using a double-lumen balloon (Microvention, Tustin, CA, USA). This technique allows the penetration of the embolic agent in the transosseous branches by forming a counter-pressure with the inflated balloon. This technique may be useful to achieve complete occlusion of TS DAVFs by endovascular means.

  16. Relevance of Occlusion Test in Endovascular Coiling of Posterior Cerebral Artery (P2 Segment) Aneurysms

    PubMed Central

    Jayakumar, P. N.; Desai, S.; Srikanth, S. G.; Ravishankar, S.; Kovoor, J. M. E.

    2004-01-01

    Summary P2 segment aneurysms are located on the posterior cerebral artery (PCA) between the junction of the posterior communicating artery with the PCA and the quadrigeminal cisternal part of the PCA. We reviewed our experience with endovascular coiling in such aneurysms. Clinical and pre-procedural data from four patients, referred for endovascular treatment of P2 segment aneurysms, were retrospectively studied for factors influencing post-interventional neurological deficits caused by ischemia of the PCA distal territory. Balloon occlusion was done in three patients and patient tolerance was assessed using clinical and anatomic criteria. Embryologic and anatomic features of the PCA were reviewed. Balloon occlusion test and endovascular coiling of aneurysms was possible in three patients. Control angiogram after embolization showed elimination of aneurysms from the circulation and the distal PCA filled through leptomeningeal anastomoses. One patient deteriorated due to aneurysmal rupture soon after the balloon occlusion test and coiling could not be done. In the other three patients post-intervention CT and MRI images showed PCA territory infarcts in spite of demonstration of good collateral circulation distal to the occluded PCA. In conclusion, P2 aneurysms can be effectively treated by endovascular coiling without a balloon occlusion test. While the balloon occlusion test does not contribute to clinical decision-making it may be associated with potential morbidity and mortality. PMID:20587236

  17. Coil embolization for pulmonary artery injury caused by chest tube drainage.

    PubMed

    Shigefuku, Shunsuke; Kudo, Yujin; Saguchi, Toru; Maeda, Junichi

    2017-05-01

    Pulmonary artery injury caused by chest tube drainage is rare, but it requires prompt diagnosis to perform urgent surgical repair. We report that a 53-year-old man who suffered from pulmonary artery injury by chest tube drainage was successfully treated by coil embolization. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Healing of saccular aneurysms following platinum coil embolization: lack of improved efficacy with vitamin C supplementation.

    PubMed

    Dai, Daying; Yong-Hong, Ding; Rezek, Issa; Lewis, Debra A; Kallmes, David F; Kadirvel, Ramanathan

    2013-11-01

    To test the hypothesis that systemic administration of vitamin C, through its action of stimulating collagen synthesis and crosslinking, would decrease the recurrence and improve the occlusion of experimental aneurysms treated with platinum coils. Experimental aneurysms were created in female rabbits and were embolized with platinum coils (>30% packing density). The animals were divided into three groups: group 1 (n=6) rabbits served as controls, group 2 (n=5) rabbits were fed with a vitamin C supplemented feed and group 3 (n=8) rabbits were medicated with vitamin C pills. Digital subtraction angiography was used to evaluate stability after embolization. Subjects were euthanized at 12 weeks after coil implantation, and serum vitamin C levels were then measured. Histological samples were examined with a grading system (range 0-12) based on the neck and dome features. Masson Trichrome staining was used to evaluate collagen deposition. Parametric data were analyzed with one way analysis of variance and non-parametric data were examined using a Kruskal-Wallis test. There were no significant differences between groups in mean aneurysm size. Mean serum vitamin C concentration was significantly higher in group 3 and group 2 compared with group 1, while vitamin C levels between group 2 and group 3 were statistically comparable. Coil compaction was noted in one of six subjects in group 1 and in three of eight subjects in group 3. All of the remaining aneurysms in the test and control groups showed stable occlusion. There were no significant differences in histological scores or collagen deposition among groups. Vitamin C supplementation following platinum coil embolization does not demonstrate improvement of long term occlusion rates of aneurysms.

  19. Coil embolization of an aneurysmal type B dissection persistent false lumen after visceral hybrid repair.

    PubMed

    Riga, Celia; Bicknell, Colin; Jenkins, Michael; Hamady, Mohamad

    2009-01-01

    Complex aortic dissections with subsequent dilatation may be managed by using a visceral hybrid approach. In some cases, however, there is substantial retrograde blood flow into the false lumen, leaving a pressurized aneurysmal segment. The authors describe a novel treatment method whereby successful seal of a distal type 1 endoleak was achieved with coil embolization and a liquid injectable embolic agent. The patient was followed up for 2 years without further aortic dilatation or complications.

  20. Embolization with Tornado coils to control bleeding from an arterioureteral fistula.

    PubMed

    Jacobs, Bruce L; Maranchie, Jodi K

    2007-12-01

    Arterioureteral fistulae are rare, but potentially life-threatening causes of bleeding. We present a case of an 82 year-old woman with refractory, transfusion-dependent bleeding from an arterial fistula to her right ureteral stump, following right radical nephrectomy for advanced renal cell carcinoma. Cystoscopy with retrograde ureteral stump embolization using Tornado (Cook Medical, Bloomington, Indiana, USA) coils plus a slurry of thrombin-soaked Gelfoam (Pfizer Inc., New York, New York, USA) was performed, which led to prompt resolution of the patient's hematuria requiring no further hospitalizations or transfusions. Retrograde insertion of coils and injection of thrombin-soaked Gelfoam can be a minimally invasive, safe, and durable alternative for controlling hemorrhage from an arterioureteral fistula to a ureteral stump.

  1. Internal Maxillary Artery Preoperative Embolization Using n-Butyl Cyanoacrylate and Pushable Coils for Temporomandibular Joint Ankylosis Surgery.

    PubMed

    Alderazi, Yazan J; Shastri, Darshan; Wessel, John; Mathew, Melvin; Kass-Hout, Tareq; Aziz, Shahid R; Prestigiacomo, Charles J; Gandhi, Chirag D

    2017-05-01

    Temporomandibular joint (TMJ) ankylosis causes disability through impaired digestion, mastication, speech, and appearance. Surgical treatment increases range of motion with resultant functional improvement. However, substantial perioperative blood loss can occur (up to 3 L) if the internal maxillary artery (IMAX) is injured as it traverses the ankylotic mass. Achieving hemostasis is difficult because of limited proximal IMAX access and poor visualization. Our aim is to investigate the technical feasibility and preliminary safety of preoperative IMAX embolization in patients undergoing TMJ ankylosis surgery. Case series using chart reviews of 2 patients who underwent preoperative embolization before TMJ ankylosis surgery. Both patients were women (28 and 51 years old) who had severely restricted mouth opening. Embolization was performed using general anesthesia with nasal intubation on the same day of TMJ surgery. Both patients underwent bilateral IMAX embolization using pushable coils (Vortex, Boston Scientific) of distal IMAX followed by n-butyl-cyanoacrylate (Trufill, Cordis) embolization from coil mass up to proximal IMAX. There were no complications from the embolization procedures. Both patients had normal neurologic examination results. TMJ surgery occurred with minimal operative blood loss (≤300 mL for each surgery). Maximum postoperative mouth opening was 35 mm and 34 mm, respectively. One patient had a postoperative TMJ wound infection that was managed with antibiotics. Preoperative IMAX embolization before TMJ ankylosis surgery is technically feasible with encouraging preliminary safety. There were no complications from the embolization procedures and surgeries occurred with low volumes of blood loss. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Retreatment of Recurrent Internal Carotid-Posterior Communicating Artery Aneurysm after Coil Embolization

    PubMed Central

    TOYOTA, Shingo; TAKI, Takuyu; WAKAYAMA, Akatsuki; YOSHIMINE, Toshiki

    2015-01-01

    Internal carotid-posterior communicating artery (IC-PC) aneurysms account for more than 20% of all intracranial aneurysms. As a result of the increase in coiling, there has also been an increase in recurrent IC-PC aneurysms after coiling. We present our experience of 10 recurrent IC-PC aneurysms after coiling that were retreated using surgical or endovascular techniques in order to discuss the choice of treatment and the points of clipping without removal of coils. From 2007 to 2014, 10 recurrent IC-PC aneurysms after coiling were retreated. When the previous frames covered the aneurysms all around or almost around except a part of the neck, coiling was chosen. In other cases, clipping was chosen. Clipping was attempted without removal of coils when it was technically feasible. Among the 10 IC-PC aneurysms retreated, 3 were retreated with coiling and 7 were retreated with clipping. In all three cases retreated with coiling, almost complete occlusion was accomplished. In the seven cases retreated with clipping, coil extrusion was observed during surgery in six cases. In most of them, it was necessary to dissect strong adhesions around the coiled aneurysms and to utilize temporary occlusion of the internal carotid artery. In all seven cases, neck clipping was accomplished without the removal of coils. There were no neurological complications in any cases. The management of recurrent lesions of embolized IC-PC aneurysms requires appropriate choice of treatment using both coiling and clipping. Clipping, especially without the removal of coils, plays an important role in safe treatment. PMID:26437796

  3. Retreatment of Recurrent Internal Carotid-Posterior Communicating Artery Aneurysm after Coil Embolization.

    PubMed

    Toyota, Shingo; Taki, Takuyu; Wakayama, Akatsuki; Yoshimine, Toshiki

    2015-01-01

    Internal carotid-posterior communicating artery (IC-PC) aneurysms account for more than 20% of all intracranial aneurysms. As a result of the increase in coiling, there has also been an increase in recurrent IC-PC aneurysms after coiling. We present our experience of 10 recurrent IC-PC aneurysms after coiling that were retreated using surgical or endovascular techniques in order to discuss the choice of treatment and the points of clipping without removal of coils. From 2007 to 2014, 10 recurrent IC-PC aneurysms after coiling were retreated. When the previous frames covered the aneurysms all around or almost around except a part of the neck, coiling was chosen. In other cases, clipping was chosen. Clipping was attempted without removal of coils when it was technically feasible. Among the 10 IC-PC aneurysms retreated, 3 were retreated with coiling and 7 were retreated with clipping. In all three cases retreated with coiling, almost complete occlusion was accomplished. In the seven cases retreated with clipping, coil extrusion was observed during surgery in six cases. In most of them, it was necessary to dissect strong adhesions around the coiled aneurysms and to utilize temporary occlusion of the internal carotid artery. In all seven cases, neck clipping was accomplished without the removal of coils. There were no neurological complications in any cases. The management of recurrent lesions of embolized IC-PC aneurysms requires appropriate choice of treatment using both coiling and clipping. Clipping, especially without the removal of coils, plays an important role in safe treatment.

  4. IN VITRO QUANTIFICATION OF THE SIZE DISTRIBUTION OF INTRASACCULAR VOIDS LEFT AFTER ENDOVASCULAR COILING OF CEREBRAL ANEURYSMS.

    PubMed

    Sadasivan, Chander; Brownstein, Jeremy; Patel, Bhumika; Dholakia, Ronak; Santore, Joseph; Al-Mufti, Fawaz; Puig, Enrique; Rakian, Audrey; Fernandez-Prada, Kenneth D; Elhammady, Mohamed S; Farhat, Hamad; Fiorella, David J; Woo, Henry H; Aziz-Sultan, Mohammad A; Lieber, Baruch B

    2013-03-01

    Endovascular coiling of cerebral aneurysms remains limited by coil compaction and associated recanalization. Recent coil designs which effect higher packing densities may be far from optimal because hemodynamic forces causing compaction are not well understood since detailed data regarding the location and distribution of coil masses are unavailable. We present an in vitro methodology to characterize coil masses deployed within aneurysms by quantifying intra-aneurysmal void spaces. Eight identical aneurysms were packed with coils by both balloon- and stent-assist techniques. The samples were embedded, sequentially sectioned and imaged. Empty spaces between the coils were numerically filled with circles (2D) in the planar images and with spheres (3D) in the three-dimensional composite images. The 2D and 3D void size histograms were analyzed for local variations and by fitting theoretical probability distribution functions. Balloon-assist packing densities (31±2%) were lower ( p =0.04) than the stent-assist group (40±7%). The maximum and average 2D and 3D void sizes were higher ( p =0.03 to 0.05) in the balloon-assist group as compared to the stent-assist group. None of the void size histograms were normally distributed; theoretical probability distribution fits suggest that the histograms are most probably exponentially distributed with decay constants of 6-10 mm. Significant ( p <=0.001 to p =0.03) spatial trends were noted with the void sizes but correlation coefficients were generally low (absolute r <=0.35). The methodology we present can provide valuable input data for numerical calculations of hemodynamic forces impinging on intra-aneurysmal coil masses and be used to compare and optimize coil configurations as well as coiling techniques.

  5. Coil-Assisted Retrograde Transvenous Obliteration (CARTO) for the Treatment of Portal Hypertensive Variceal Bleeding: Preliminary Results

    PubMed Central

    Lee, Edward W; Saab, Sammy; Gomes, Antoinette S; Busuttil, Ronald; McWilliams, Justin; Durazo, Francisco; Han, Steven-Huy; Goldstein, Leonard; Tafti, Bashir A; Moriarty, John; Loh, Christopher T; Kee, Stephen T

    2014-01-01

    OBJECTIVES: To describe the technical feasibility, safety, and clinical outcomes of coil-assisted retrograde transvenous obliteration (CARTO) in treating portal hypertensive non-esophageal variceal hemorrhage. METHODS: From October 2012 to December 2013, 20 patients who received CARTO for the treatment of portal hypertensive non-esophageal variceal bleeding were retrospectively evaluated. All 20 patients had at least 6-month follow-up. All patients had detachable coils placed to occlude the efferent shunt and retrograde gelfoam embolization to achieve complete thrombosis/obliteration of varices. Technical success, clinical success, rebleeding, and complications were evaluated at follow-up. RESULTS: A 100% technical success rate (defined as achieving complete occlusion of efferent shunt with complete thrombosis/obliteration of bleeding varices and/or stopping variceal bleeding) was demonstrated in all 20 patients. Clinical success rate (defined as no variceal rebleeding) was 100%. Follow-up computed tomography after CARTO demonstrated decrease in size with complete thrombosis and disappearance of the varices in all 20 patients. Thirteen out of the 20 had endoscopic confirmation of resolution of varices. Minor post-CARTO complications, including worsening of esophageal varices (not bleeding) and worsening of ascites/hydrothorax, were noted in 5 patients (25%). One patient passed away at 24 days after the CARTO due to systemic and portal venous thrombosis and multi-organ failure. Otherwise, no major complication was noted. No variceal rebleeding was noted in all 20 patients during mean follow-up of 384±154 days. CONCLUSIONS: CARTO appears to be a technically feasible and safe alternative to traditional balloon-occluded retrograde transvenous obliteration or transjugular intrahepatic portosystemic shunt, with excellent clinical outcomes in treating portal hypertensive non-esophageal variceal bleeding. PMID:25273155

  6. Brain 'Embolism' Detected by Magnetic Resonance Imaging During Percutaneous Mitral Balloon Commissurotomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rocha, Paulo; Qanadli, Salah D.; Strumza, Pierre

    1999-05-15

    Purpose: The common finding of thrombi between the bifoil balloons when they were extracted after mitral dilation prompted us to look for evidence of minor brain embolisms using the sensitive technique of BMRI (brain magnetic resonance T2-weighted imaging). Methods: BMRI was performed within 48 hr before and after a percutaneous mitral balloon commissurotomy (PMBC) in each of the 63 patients in this study. Results: There was evidence (hyperintensity foci: HI) of a previous asymptomatic brain embolism in 38 of 63 patients before PMBC and a new HI appeared in 18 of 63 patients after the procedure. New HI signals weremore » found exclusively in the white matter in 8 of 18 patients and in only 3 of 18 were HI signs larger than 1 cm. One patient, with an HI signal >1 cm in the thalamus and another <1 cm in the brain stem, presented diplopia accompanied by other minor clinical signs. The differences in HI rate among four subgroups (1, older vs younger than 43 years; 2, sinus rhythm vs atrial fibrillation; 3, echo score <8 vs >8; 4, patients from western countries vs the others) were not statistically significant, probably because the number of patients in each subgroup was low. Patients in atrial fibrillation had slightly more (not significant) HI before PMBC (15/20, 75%) than patients in sinus rhythm (23/43, 53%), but after PMBC their HI frequencies were similar (atrial fibrillation: 5/20, 25%; sinus rhythm: 13/43, 30%). Conclusion: Brain microembolism is frequent during PMBC, but is often anatomically limited and free from clinical signs in most cases. Brain embolism seems to be related mainly to the procedure itself and not the features of the patient.« less

  7. [Transcatheter embolization for huge pulmonary arteriovenous fistula using metallic "spider" and spring embolus--application of hand-made metallic "spider" using partial monorail technique].

    PubMed

    Hirota, S; Sako, M; Fujita, Y; Hasegawa, Y; Sugimoto, K; Suzuki, Y; Kono, M

    1992-07-25

    We performed transcatheter embolization in two cases with huge pulmonary arteriovenous fistula (AVF) using a metallic "spider" and spring embolus. Conventional spring embolus or detachable balloon could not be used in these cases. Metallic spider was indicated for pulmonary AVF with a feeding artery diameter of more than 16 mm to prevent embolus passing through the AVF. In the first case, we used large handmade metallic spiders of 25 mm in diameter followed by embolization by numerous spring coils. At that time, a partial monorail technique was newly devised to carry the large metallic spider into the feeding artery, otherwise the spider could not pass into a 9F catheter. After embolization, symptoms and PaO2 in arterial blood improved remarkably in both cases. In the second case, a spring coil migrated into the normal pulmonary artery, but no infarction resulted. In conclusion, the metallic spider was very useful for embolization of hugee pulmonary AVF to avoid the embolus passing through and to tangle spring coils together with it. If commercially available "spiders" are too small, ones can be made easily.

  8. Successful Transarterial Guglielmi Detachable Coil Embolization of Post-Traumatic Fistula between a Posterior Communicating Artery Aneurysm and the Cavernous Sinus

    PubMed Central

    Chen, Y.; Jiang, D-Y.; Tan, H-Q.; Wang, L-H.; Chen, X-Y.; Sun, J-H.

    2009-01-01

    Summary We describe a case of a post-traumatic posterior communicating artery (PCoA) aneurysmcavernous sinus fistula, which is an extremely rare complication of craniocerebral trauma, successfully treated with endosaccular coil embolization via transarterial route. Endosaccular embolization with Guglielmi detachable coils via transarterial route appears to be a feasible, effective and minimally invasive option for the treatment of post-traumatic fistula between the PCoA aneurysm with a small ostia and the cavernous sinus in the subacute phase. PMID:20465883

  9. Application of endovascular coiling and subsequent Onyx 34 embolization in anterior communicating artery aneurysms with adjacent hematoma.

    PubMed

    Fang, Yi-Bin; Li, Qiang; Yang, Peng-Fei; Zhang, Qi; Wu, Yi-Na; Feng, Zheng-Zhe; Huang, Qing-Hai; Xu, Yi; Liu, Jian-Min

    2014-08-01

    Small anterior communicating artery aneurysms with recurrent bleeding and adjacent hematoma may have a high risk of post-operative rebleeding. This clinical study summarizes our preliminary experience with this subset of aneurysms, which were treated with endovascular coiling and subsequent Onyx 34 embolization. We retrospectively reviewed the data of 9 patients suffering from small anterior communicating artery aneurysms treated with the combination of coils and Onyx. The clinical characteristics, angiographic outcomes, and follow-up results are reviewed. Endovascular coiling and Onyx embolization were successfully accomplished in all 9 cases. The Raymond scale ratings of the treatments are all class I with the parent arteries kept patent. One patient died of severe brain edema on the 5th post-operative day. The modified Rankin scale (mRS) score for the other 8 patients at follow-ups (6m to 26m, 15.8m on average) was 0 in 5 cases, 1 in 2 cases, and 3 in 1 case. Seven of 8 patients (87.5%) underwent angiographic follow-up that demonstrated persistent durable occlusion with no recanalization. Endovascular coiling and subsequent Onyx 34 embolization may be effective in treating anterior communicating artery aneurysms with adjacent hematoma. Further studies with larger sample size and adequate follow-up are required to verify its safety and efficacy as well as to evaluate the long-term outcome. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Safety and efficacy of superior rectal artery embolization with particles and metallic coils for the treatment of hemorrhoids (Emborrhoid technique).

    PubMed

    Zakharchenko, A; Kaitoukov, Y; Vinnik, Y; Tradi, F; Sapoval, M; Sielezneff, I; Galkin, E; Vidal, V

    2016-11-01

    The purpose of this study was to comprehensively evaluate the short-term outcomes after percutaneous embolization of the superior rectal artery (SRA) with metallic coils and particles for the management of hemorrhoids. Forty patients (15 men, 25 women) with a mean age of 35±5 years (SD) (range: 25-65 years) were prospectively enrolled. All patients had symptomatic hemorrhoids. The distribution of internal hemorrhoids was as follows: grade I (n=6, 16%); grade II (n=28, 69%) and grade III (n=6; 15%). All patients had percutaneous embolization of the SRA with metallic coils and synthetic polyvinyl alcohol particles. Follow-up evaluation included clinical examination, rectoscopy, histopathological analysis of rectal mucosa, duplex Doppler blood flow quantification, electromyography, sphincterometry of the anal sphincter and analysis of patient satisfaction. No immediate complications were observed and no patients had anal pain syndrome after embolization. Hemorrhoids showed a 43% size reduction after embolization (P<0.05). Taking into account the symptom resolutions such as irritation, discomfort, bloody discharge and pain, satisfaction was observed in 5/6 (83%) patients with grade III hemorrhoids and 32/34 patients (94%) with grades I-II hemorrhoids. One month after embolization, anal sphincter contractility normalized and no changes in anal electromyography were observed. Blood flow in the hemorrhoidal plexus dropped from 109±1.2ml/min/100g (SD) before treatment to 60.2±4.4ml/min/100g (SD) (P<0.05) the day after embolization and remained unchanged one month after embolization. Our study demonstrates that embolization of SRA with particle and coils does not lead to ischemia in patients with symptomatic hemorrhoids. Short-term results with regard to symptom management for hemorrhoidal disease are very encouraging and should stimulate further prospective and multicenter studies. Copyright © 2016 Editions françaises de radiologie. Published by Elsevier Masson SAS

  11. Portal Vein Embolization before Right Hepatectomy: Improved Results Using n-Butyl-Cyanoacrylate Compared to Microparticles Plus Coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guiu, Boris, E-mail: boris.guiu@chu-dijon.fr; Bize, Pierre; Gunthern, Daniel

    Background: There is currently no consensus in the literature on which embolic agent induces the greatest degree of liver hypertrophy after portal vein embolization (PVE). Only experimental results in a pig model have demonstrated an advantage of n-butyl-cyanoacrylate (NBCA) over 3 other embolic materials (hydrophilic gel, small and large polyvinyl alcohol particles) for PVE. Therefore, the aim of this human study was to retrospectively compare the results of PVE using NBCA with those using spherical microparticles plus coils. Methods: A total of 34 patients underwent PVE using either NBCA (n = 20), or spherical microparticles plus coils (n = 14).more » PVE was decided according to preoperative volumetry on the basis of contrast-enhanced CT. Groups were compared for age, sex, volume of the left lobe before PVE and future remnant liver ratio (FRL) (volume of the left lobe/total liver volume - tumor volume). The primary end point was the increase in left lobe volume 1 month after PVE. Secondary end points were procedure complications and biological tolerance. Results: Both groups were similar in terms of age, sex ratio, left lobe volume, and FRL before PVE. NBCA induced a greater increase in volume after PVE than did microparticles plus coils (respectively, +74 {+-} 69 % and +23 {+-} 14 %, p < 0.05). The amount of contrast medium used for the procedure was significantly larger when microparticles and coils rather than NBCA were used (respectively, 264 {+-} 43 ml and 162 {+-} 34 ml, p < 0.01). The rate of PVE complications as well as the biological tolerance was similar in both groups. Conclusion: NBCA seems more effective than spherical microparticles plus coils to induce left-lobe hypertrophy.« less

  12. Coils versus gelatin particles with or without intraarterial antibiotics for partial splenic embolization: a comparative evaluation.

    PubMed

    Masada, Tetsuya; Tanaka, Toshihiro; Sakaguchi, Hiroshi; Nakagomi, Masahiro; Miura, Yuko; Hidaka, Teruyuki; Sato, Yozo; Sato, Takeshi; Inoue, Masayoshi; Furuich, Kinya; Nishiofuku, Hideyuki; Kichikawa, Kimihiko

    2014-06-01

    To compare the efficacy, complications, and inflammatory levels in partial splenic embolization (PSE) with coils or gelatin sponge (GS) particles with or without intraarterial antibiotic agents. Forty-four patients with hypersplenism treated by PSE were assessed. GS particles were used in 31 patients, and coils were used in 13 patients. In 17 of the 31 patients who received GS, GS suspended in antibiotic solution was injected via the splenic artery. In the other 14 patients, antibiotic agents were not used. In all 13 coil group patients, an antibiotic solution was intraarterially injected before embolization. Platelet counts were compared between the GS and coil groups. Complications and serum C-reactive protein (CRP) levels were compared among the three groups. There were no significant differences in platelet counts and platelet increased ratios at 6 months (10.0 × 10(4)/µL and 193% in the GS group vs 9.0 × 10(4)/µL and 221% in the coil group), and no significant differences in frequencies of complications. However, one splenic abscess occurred in a patient treated with GS without antibiotics, resulting in death. The mean serum CRP level in the GS with antibiotic group at 2 weeks was significantly lower than in the other two groups. The efficacy of PSE is similar with the use of coils versus GS particles. Prophylactic intraarterial antibiotic treatment could be useful in preventing inflammatory reactions after PSE. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  13. PTA of supra-aortic arteries with temporary balloon occlusion to avoid distal embolism.

    PubMed

    Koike, T; Minakawa, T; Abe, H; Takeuchi, S; Sasaki, O; Nishimaki, K; Tanaka, R

    1992-03-01

    Percutaneous transluminal angioplasty (PTA) was carried out in eight patients with cervical arterial stenosis; six in the subclavian and brachiocephalic arteries (5 with subclavian steal syndrome), one in the common carotid artery, and one in both the brachiocephalic and common carotid arteries (with subclavian steal syndrome). The PTA balloon catheters were introduced via the femoral artery in seven and brachial artery in one. To prevent distal embolization through the vertebral and internal carotid arteries, the blood flow in these vessels was temporarily occluded with a balloon catheter. The dilation of the stenotic areas was generally satisfactory. Antegrade blood flow was promptly obtained in the vertebral artery even in patients with subclavian steal syndrome. In all patients, the clinical symptoms improved. Two patients underwent repeat PTA because of restenosis.

  14. Balloon-Assisted Occlusion of the Internal Iliac Arteries in Patients with Placenta Accreta/Percreta

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bodner, Leonard J.; Nosher, John L.; Gribbin, Christopher

    2006-06-15

    Background. Placenta accreta/percreta is a leading cause of third trimester hemorrhage and postpartum maternal death. The current treatment for third trimester hemorrhage due to placenta accreta/percreta is cesarean hysterectomy, which may be complicated by large volume blood loss. Purpose. To determine what role, if any, prophylactic temporary balloon occlusion and transcatheter embolization of the anterior division of the internal iliac arteries plays in the management of patients with placenta accreta/percreta. Methods. The records of 28 consecutive patients with a diagnosis of placenta accreta/percreta were retrospectively reviewed. Patients were divided into two groups. Six patients underwent prophylactic temporary balloon occlusion, followedmore » by cesarean section, transcatheter embolization of the anterior division of the internal iliac arteries and cesarean hysterectomy (n = 5) or uterine curettage (n = 1). Twenty-two patients underwent cesarean hysterectomy without endovascular intervention. The following parameters were compared in the two groups: patient age, gravidity, parity, gestational age at delivery, days in the intensive care unit after delivery, total hospital days, volume of transfused blood products, volume of fluid replacement intraoperatively, operating room time, estimated blood loss, and postoperative morbidity and mortality. Results. Patients in the embolization group had more frequent episodes of third trimester bleeding requiring admission and bedrest prior to delivery (16.7 days vs. 2.9 days), resulting in significantly more hospitalization time in the embolization group (23 days vs. 8.8 days) and delivery at an earlier gestational age than in those in the surgical group (32.5 weeks). There was no statistical difference in mean estimated blood loss, volume of replaced blood products, fluid replacement needs, operating room time or postoperative recovery time. Conclusion. Our findings do not support the contention that in patients

  15. Relationship between pseudoaneurysm formation and biloma after successful transarterial embolization for severe hepatic injury: permanent embolization using stainless steel coils prevents pseudoaneurysm formation.

    PubMed

    Hagiwara, Akiyoshi; Tarui, Takehiko; Murata, Atsuo; Matsuda, Takeaki; Yamaguti, Yoshihiro; Shimazaki, Shuji

    2005-07-01

    The purpose of this study was to determine the association between bilomas and pseudoaneurysm complications after severe hepatic injury. Angiography was performed in patients with American Association for the Surgery of Trauma grade > or = III hepatic injury on contrast-enhanced computed tomographic scanning. When contrast extravasation was observed, transarterial embolization (TAE) was performed. After TAE, technetium-99m pyridoxyl-5-methyl-tryptophan cholescintigraphy was performed to detect the coexistence of bilomas. Follow-up angiography was performed when a biloma was detected. Eighty consecutive patients underwent angiography; after angiography, five patients died. The remaining 75 patients who underwent cholescintigraphy were included in this study. All 11 patients who had bilomas had angiographic evidence of contrast extravasation. The biloma frequency was higher in patients with grades IV and V injuries than in those with grade III injury (p = 0.024). Follow-up angiography revealed pseudoaneurysms in 7 of these 11 patients. All six patients in whom only gelatin sponge pledget injection was used to embolize had pseudoaneurysms. Among them, two patients had computed tomographic evidence of massive intra-abdominal fluid collection. In contrast, only one of five patients who received the combination of gelatin sponge pledget injection and stainless steel coils to permanently embolize injured arteries had a pseudoaneurysm. In this patient, the pseudoaneurysm was found in the peripheral part of the collateral vessels. All patients with pseudoaneurysms underwent repeat TAE and were discharged from the hospital uneventfully. In patients with high-grade hepatic injury and arterial bleeding who developed biloma, use of a gelatin sponge, an absorbable embolic material, is associated with a risk of pseudoaneurysm formation. Permanent arterial embolization using stainless steel coils is indicated to decrease this risk.

  16. Long-term follow-up after transvenous single coil embolization of patent ductus arteriosus in dogs.

    PubMed

    Hildebrandt, N; Schneider, C; Schweigl, T; Schneider, M

    2010-01-01

    Long-term follow-up studies after interventional therapy of patent ductus arteriosus (PDA) in dogs are rare. Transvenous PDA embolization with a single detachable coil is a highly effective method in patients with an angiographically determined PDA≤4.0 mm. Twenty-eight dogs with an angiographic PDA≤4.0 mm were included. Prospective follow-up study after PDA coil embolization. The median follow-up time was 792 days (range, 2-3, 248 days). The rate of complete closure demonstrated by Doppler color flow was 54% at day 3 after intervention and the final cumulative rate was 71%. The rate of complete closure was significantly different between small and moderately sized PDA over the study period (P<.0001) and finally was 100 and 50%, respectively. In 16 dogs with complete closure, no recanalization was found. Disappearance of the continuous heart murmur was found in 89% after 3 days, and this increased to a final cumulative rate of 96%. Indexed left ventricular internal diameter in diastole (LVDd-I) decreased significantly (P<.0001). In the group with moderately sized PDA, a significant difference (P=.0256) was seen in LVDd-I between patients with and without residual shunt after exclusion of patients with persistent severe mitral valve regurgitation. Long-term follow-up after single coil embolization showed complete closure in all small PDA but a residual shunt with mild hemodynamic consequences was present in half of the moderately sized PDA. Copyright © 2010 by the American College of Veterinary Internal Medicine.

  17. Periprocedural safety of aneurysm embolization with the Medina Coil System: the early human experience.

    PubMed

    Turk, Aquilla S; Maia, Orlando; Ferreira, Christian Candido; Freitas, Diogo; Mocco, J; Hanel, Ricardo

    2016-02-01

    Intracranial saccular aneurysms, if untreated, carry a high risk of morbidity and mortality from intracranial bleeding. Embolization coils are the most common treatment. We describe the periprocedural safety and performance of the initial human experience with the next generation Medina Coil System. The Medina Coil System is a layered three-dimensional coil made from a radiopaque, shape set core wire, and shape memory alloy outer coil filaments. Nine aneurysms in five patients were selected for treatment with the Medina Coil System. Nine aneurysms in five patients, ranging from 5 to 17 mm in size in various locations, were treated with the Medina Coil System. No procedural or periprocedural complications were encountered. Procedure times, number of coils used to treat the aneurysm, and use of adjunctive devices were much less than anticipated if conventional coil technology had been used. The Medina Coil System is a next generation coil that combines all of the familiar and expected procedural safety and technique concepts associated with conventional coils. We found improved circumferential aneurysm filling, which may lead to improved long term outcomes, with fewer devices and faster operating times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Flow-Diverting Devices versus Coil Embolization for Intracranial Aneurysms: A Systematic Literature Review and Meta-analysis.

    PubMed

    Zhou, Geng; Zhu, Yue-Qi; Su, Ming; Gao, Kai-Di; Li, Ming-Hua

    2016-04-01

    To review the literature on flow-diverting device (FDD) treatments for intracranial aneurysms (IAs) and to compare the safety and efficacy of FDDs with coil embolization treatment (CET) for IAs using a meta-analysis of published studies. A systematic electronic search was conducted of PubMed, Springer Link, EBSCO, and the Cochrane Database on all accessible published articles through September 2015. Abstracts, full-text manuscripts, and the reference lists of retrieved articles were analyzed. Studies that explicitly compared FDD and CET approaches to the treatment of IAs were included. Odds ratios (ORs) and 95% CIs were calculated for the complete occlusion rate and the morbidity rate using a random-effects model. Nine studies were included in the analysis, containing retrospectively collected data for 863 patients. FDD treatment showed a significantly higher complete occlusion rate than CET (OR = 3.13; 95% confidence interval [CI], 2.11-4.65) and the subgroup of stent-assisted coiling did (OR = 2.08; 95% CI, 1.34-3.24). FDDs did not achieve a significantly lower overall morbidity rate compared with CET (OR = 0.87; 95% CI, 0.45-1.69) or the SAC (stent-assisted coiling) subgroup (OR = 0.86; 95% CI, 0.33-2.26), and our results did not show a significant difference in mortality between the two techniques. FDD treatment of IAs yielded satisfactory results in complete occlusion rate compared with CET. The FDD procedure is feasible and has no significant difference in morbidity risk. Despite the findings reported herein, further validation with well-designed, multicenter randomized controlled trials is needed. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagspiel, Klaus D., E-mail: kdh2n@virginia.edu; Nambiar, Ashwin, E-mail: uvashwin@gmail.com; Hagspiel, Lauren M., E-mail: lmh4gg@virginia.edu

    2013-06-15

    Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Fivemore » arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.« less

  20. Percutaneous protective coil occlusion of the proximal inferior mesenteric artery before N-butyl cyanoacrylate embolization of type II endoleaks after endovascular repair of abdominal aortic aneurysms.

    PubMed

    Chao, Christine P; Paz-Fumagalli, Ricardo; Walser, Eric M; McKinney, J Mark; Stockland, Andrew H; Falkensammer, Jürgen; Hakaim, Albert G; Oldenburg, W Andrew

    2006-11-01

    Bowel ischemia can complicate treatment of type II endoleak with liquid or semiliquid agents such as n-butyl cyanoacrylate (NBCA) if nontarget embolization of the inferior mesenteric artery (IMA) occurs. The current report describes four cases of type II endoleak in which the IMA was the main outflow vessel and was prophylactically occluded with embolization coils before NBCA injection into the endoleak nidus. The purpose was to prevent unintentional embolization of the NBCA into IMA branches. If feasible, protective IMA coil occlusion should be considered in type II endoleaks with IMA outflow in cases of NBCA embolization.

  1. Video-assisted open supraclavicular sympathectomy following air embolism.

    PubMed

    Shpolyanski, G; Hashmonai, M; Rudin, M; Abaya, N; Kaplan, U; Kopelman, D

    2012-01-01

    Air embolism is a relatively rare complication of thoracoscopic surgery. Open supraclavicular sympathectomy was indicated to overcome the risk of re-embolization. A novel video-assisted technique was performed. conclusions: The previously prevalent open supraclavicular sympathectomy is a good choice for avoiding air embolism. Laparoscopic instrumentation and technology can be used to improve open procedures, especially when exposure and visibility are limited. Sometimes we should remember to use the experience of our teachers.

  2. Usefulness of monochromatic imaging with metal artifact reduction software for computed tomography angiography after intracranial aneurysm coil embolization.

    PubMed

    Shinohara, Yuki; Sakamoto, Makoto; Iwata, Naoki; Kishimoto, Junichi; Kuya, Keita; Fujii, Shinya; Kaminou, Toshio; Watanabe, Takashi; Ogawa, Toshihide

    2014-10-01

    Recently, a newly developed fast-kV switching dual energy CT scanner with a gemstone detector generates virtual high keV images as monochromatic imaging (MI). Each MI can be reconstructed by metal artifact reduction software (MARS) to reduce metal artifact. To evaluate the degree of metal artifacts reduction and vessel visualization around the platinum coils using dual energy CT with MARS. Dual energy CT was performed using a Discovery CT750 HD scanner (GE Healthcare, Milwaukee, WI, USA). In a phantom study, we measured the mean standard deviation within regions of interest around a 10-mm-diameter platinum coil mass on MI with and without MARS. Thirteen patients who underwent CTA after endovascular embolization for cerebral aneurysm with platinum coils were included in a clinical study. We visually assessed the arteries around the platinum coil mass on MI with and without MARS. Each standard deviation near the coil mass on MI with MARS was significantly lower than that without MARS in a phantom study. On CTA of a clinical study, better visibility of neighboring arteries was obtained in 11 of 13 patients on MI with MARS compared to without MARS due to metal artifact reduction. Dual energy CT with MARS reduces metal artifact of platinum coils, resulting in favorable vessel visualization around the coil mass on CTA after embolization. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Endovascular Coil Embolization in a Postnephrostomy Renal Vein to Renal Pelvis Fistula

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anil, Gopinathan, E-mail: ivyanil10@gmail.com; Taneja, Manish

    2011-02-15

    We report the case of a 74-year-old man with post-percutaneous-nephrostomy venous hemorrhage from an iatrogenic fistula between the renal pelvis and a large tributary of the renal vein. Conservative management failed to contain the hemorrhage. Hence the fistula was occluded by coil embolization through the renal vein. This endovascular approach enabled rapid and effective stoppage of the venous bleed.There was no recurrence of the bleed or any pertinent complication at 3-month follow-up.

  4. Therapeutic Benefit of Bone Marrow–Derived Endothelial Progenitor Cell Transplantation after Experimental Aneurysm Embolization with Coil in Rats

    PubMed Central

    Li, Qianyun; Huang, Jun; Chen, Xi; Chen, Xiaoyan; Zhang, Jun; Wang, Yongting; Yang, Guo-Yuan; Zhu, Wei

    2014-01-01

    Aneurysm embolization with coil is now widely used clinically. However, the recurrence of aneurysms after embolization has always plagued neurosurgeons because the endothelial layer of the aneurysm neck loses its integrity after being embolized by coil. Bone marrow–derived endothelial progenitor cells (BM-EPCs) could be incorporated into injured endothelium and differentiate into mature endothelial cells during vascular repairing processes. The aim of our study is to explore the effects of BM-EPCs on aneurysm repairing and remodeling in a rat embolization model of abdominal aortic aneurysm. BM-EPC proliferation, migration and tube formation were not affected by super-paramagnetic iron oxide nanoparticle (SPIO) labeling compared to the controls (p>0.05). The number of SPIO-labeled cells greatly increased in EPC transplanted rats compared to that of phosphate buffered saline treated rats. SPIO-labeled EPC (SPIO-EPC) are mainly located in the aneurysm neck and surrounded by fibrous tissue. A histology study showed that the aneurysm orifice was closed with neointima and the aneurysm was filled with newly formed fibrous tissue. The SPIO-EPC accumulated in the aneurysm neck, which accelerated focal fibrous tissue remodeling, suggesting that BM-EPCs play a crucial role in repairing and remodeling the aneurysm neck orifice. PMID:24587209

  5. Stent-Assisted Coil Embolization of a Symptomatic Renal Artery Aneurysm at a Bifurcation Point.

    PubMed

    Nassiri, Naiem; Huntress, Lauren A

    2017-07-01

    Symptomatic renal artery aneurysms at bifurcation points present challenging clinical scenarios rarely amenable to endovascular repair due to concerns regarding parenchymal loss following intervention. Herein, we add to the scant body of literature describing successful endovascular repair of a saccular, symptomatic renal artery aneurysm situated at a bifurcation point. A 52-year-old woman with a 2.5-cm extraparenchymal, saccular, symptomatic left renal artery aneurysm underwent self-expanding stent-assisted detachable platinum microcoil embolization. Complete aneurysm exclusion was achieved with minimal parenchymal loss. There were no perioperative complications, and no evidence of acute kidney injury perioperatively or at 3-month follow-up. Sustained symptomatic relief was achieved. Endovascular therapy can provide safe and effective aneurysm treatment within challenging bifurcated renal artery anatomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Glue Embolization of a Blunt Traumatic Hepatic Arteriovenous Fistula under Inflow and Outflow Control.

    PubMed

    Mine, Takahiko; Murata, Satoru; Yasui, Daisuke; Yokota, Hiroyuki; Tajima, Hiroyuki; Kumita, Shin-ichiro

    2016-01-01

    We report on a rare case of blunt traumatic hepatic arteriovenous fistula arising from a pseudoaneurysm in a 35-year-old woman. Transarterial embolization was performed with n-butyl-2-cyanoacrylate, under inflow control with loose coil packing within the pseudoaneurysm and outflow control by balloon occlusion of the hepatic vein. A promising therapeutic outcome was achieved without any serious adverse events. Thus, the combination of these techniques to control inflow and outflow was successfully used to treat this rare hepatic vascular injury.

  7. Venous air embolism in consecutive balloon kyphoplasties visualised on CT imaging.

    PubMed

    Tins, Bernhard J; Cassar-Pullicino, Victor N; Lalam, Radhesh; Haddaway, Mike

    2012-09-01

    We noted a large amount of intravenous gas during balloon kyphoplasty on CT imaging. Formal assessment to understand the extent, possible causes and implications was undertaken. Ten consecutive cases of balloon kyphoplasty were performed under general anaesthesia in the prone position, on a single vertebral level using a two-step technique under combined fluoroscopic and CT guidance. CT of the affected vertebra was performed before, after, and intermittently during the procedure. In 2 cases delayed CT was carried out in the supine position. Gas was seen on CT imaging, but not on conventional fluoroscopy. The gas is most likely to be air introduced during the procedure and was seen in the epidural and paravertebral venous plexus, posterior intercostal veins, renal veins, IVC and azygos vein. The average measured volume of gas seen on the post-procedure CT imaging was 1.07 mL, range 0.16-3.97 mL. There was no correlation of the measured amount of gas to the procedure duration or location, the use of a curette or the injected cement volume. Delayed CT in the supine position no longer showed air in the local venous system. Balloon kyphoplasty is associated with the fluoroscopically invisible introduction of air into the vertebral and paravertebral veins and deep systemic veins and is likely to be much more extensive than identified on CT imaging. There is potential for serious air embolism in kyphoplasty and if there is a sudden deterioration in patient condition during the procedure the possibility of this complication needs to be considered.

  8. Endovascular treatment of ectopic bronchial artery aneurysm with brachiocephalic artery stent placement and coil embolization

    PubMed Central

    Di, Xiao; Ji, Dong-Hua; Chen, Yu; Liu, Chang-Wei; Liu, Bao; Yang, Juan

    2016-01-01

    Abstract Background: Bronchial artery aneurysm (BAA) is an uncommon but potentially life-threatening disease, and multiple BAAs are even rarer. Clinically, the tortuous and short neck of a BAA may present significant challenges for invasive intervention. Methods: This report describes the detailed process of diagnosis and treatment and includes a literature review of the etiology, clinical presentation, and therapeutic management of BAA. Results: A rare case of multiple BAAs, with one having an inflow artery arising from the brachiocephalic trunk, was referred to our hospital. The patient was successfully treated with coil embolization and brachiocephalic artery stent placement. In addition, we conducted a literature review involving 63 cases of BAA. BAA was most commonly associated with bronchiectasis and was located predominantly in the mediastinum. There was no significant difference between the diameters of the ruptured aneurysms and those of the nonruptured aneurysms (P = 0.115). Transcatheter arterial embolization was the most commonly adopted technique to treat BAA, while thoracic aortic endovascular repair was selected if the neck between the aneurysm and the aorta was short. Subgroup analysis suggested that patients with > 1 BAA were significantly more likely to be female than male (χ2 test, P = 0.034). Conclusion: Transcatheter coil embolization combined with stent placement could be a reasonable treatment option for BAAs with a tortuous and short neck. According to our literature review, patients with multiple BAAs display distinctive clinical characteristics compared with patients with a single BAA. PMID:27583854

  9. Coronary perforation with tamponade successfully managed by retrograde and antegrade coil embolization

    PubMed Central

    Boukhris, Marouane; Tomasello, Salvatore Davide; Azzarelli, Salvatore; Elhadj, Zied Ibn; Marzà, Francesco; Galassi, Alfredo Ruggero

    2015-01-01

    In recent years, retrograde approach for chronic total occlusions has rapidly evolved, enabling a higher rate of revascularization success. Compared to septal channels, epicardial collaterals tend to be more tortuous, more difficult to negotiate, and more prone to rupture. Coronary perforation is a rare but potentially life-threatening complication of coronary angioplasty, often leading to emergency cardiac surgery. We report a case of a retrograde chronic total occlusion revascularization through epicardial collaterals, complicated by both retrograde and antegrade coronary perforation with tamponade, and successfully managed by coil embolization. PMID:26136637

  10. Transarterial Coil-Augmented Onyx Embolization for Brain Arteriovenous Malformation

    PubMed Central

    Gao, Xu; Liang, Guobiao; Li, Zhiqing; Wang, Xiaogang; Yu, Chunyong; Cao, Peng; Chen, Jun; Li, Jingyuan

    2014-01-01

    Summary Onyx has been widely adopted for the treatment of arteriovenous malformations (AVMs). However, its control demands operators accumulate a considerable learning curve. We describe our initial experience using a novel injection method for the embolization of AVMs. We retrospectively reviewed the data of all 22 patients with brain AVMs (12 men, 10 women; age range, 12-68 years; mean age, 43.2 years) treated by the transarterial coil-augmented Onyx injection technique. The size of the AVMs ranged from 25 mm to 70 mm (average 35.6 mm). The technical feasibility of the procedure, procedure-related complications, angiographic results, and clinical outcome were evaluated. In every case, endovascular treatment (EVT) was completed. A total of 31 sessions were performed, with a mean injection volume of 6.1 mL (range, 1.5-16.0 mL). An average of 96.7% (range 85%-100%) estimated size reduction was achieved, and 18 AVMs could be completely excluded by EVT alone. The results remained stable on follow-up angiograms. A procedural complication occurred in one patient, with permanent mild neurologic deficit. Our preliminary series demonstrated that the coil-augmented Onyx injection technique is a valuable adjunct achieving excellent nidal penetration and improving the safety of the procedure. PMID:24556304

  11. Patient burden and patient preference: comparing magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy.

    PubMed

    Wiarda, Bart M; Stolk, Mark; Heine, Dimitri G N; Mensink, Peter; Thieme, Mai E; Kuipers, Ernst J; Stoker, Jaap

    2013-03-01

    We aimed to prospectively determine patient burden and patient preference for magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy in patients with suspected or known Crohn's disease (CD) or occult gastrointestinal bleeding (OGIB).  Consecutive consenting patients with CD or OGIB underwent magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy. Capsule endoscopy was only performed if magnetic resonance enteroclysis showed no high-grade small bowel stenosis. Patient preference and burden was evaluated by means of standardized questionnaires at five moments in time. From January 2007 until March 2009, 76 patients were included (M/F 31/45; mean age 46.9 years; range 20.0-78.4 years): 38 patients with OGIB and 38 with suspected or known CD. Seventeen patients did not undergo capsule endoscopy because of high-grade stenosis. Ninety-five percent (344/363) of the questionnaires were suitable for evaluation. Capsule endoscopy was significantly favored over magnetic resonance enteroclysis and balloon-assisted enteroscopy with respect to bowel preparation, swallowing of the capsule (compared to insertion of the tube/scope), burden of the entire examination, duration and accordance with the pre-study information. Capsule endoscopy and magnetic resonance enteroclysis were significantly preferred over balloon-assisted enteroscopy for clarity of explanation of the examination, and magnetic resonance enteroclysis was significantly preferred over balloon-assisted enteroscopy for bowel preparation, painfulness and burden of the entire examination. Balloon-assisted enteroscopy was significantly favored over magnetic resonance enteroclysis for insertion of the scope and procedure duration. Pre- and post-study the order of preference was capsule endoscopy, magnetic resonance enteroclysis and balloon-assisted enteroscopy. Capsule endoscopy was preferred to magnetic resonance enteroclysis and balloon-assisted enteroscopy

  12. Retrieval of impacted broken balloon by balloon inflation in guiding catheter.

    PubMed

    Mehta, Vimal; Pandit, Bhagya Narayan; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay; Tyagi, Sanjay

    2014-07-01

    Broken catheter fragment in a coronary artery during percutaneous coronary angioplasty is a rare complication. It can result in serious problems as a result of thrombus formation and embolization of broken fragment. We report an unusual complication of a broken balloon catheter during angioplasty, which was successfully retrieved by balloon inflation in guiding catheter technique.

  13. Initial experience of coiling cerebral aneurysms using the new Comaneci device

    PubMed Central

    Lawson, Aimee Louise Deborah; Chandran, Arun; Puthuran, Mani; Goddard, Tony; Nahser, Hans; Patankar, Tufail

    2015-01-01

    We present our initial patient experience with an innovative temporary bridging device, the Comaneci (Rapid Medical, Israel), to assist in the coiling of cerebral aneurysms. The Comaneci device confers the same benefits as balloon remodeling but without the risks of parent artery occlusion. This alleviates time pressure on the clinician, and could reduce the risk of parent artery thrombosis. Three patients were treated with the Comaneci device. Two patients had acute ruptured posterior communicating aneurysms and one patient was treated electively for a carotico-ophthalmic aneurysm. Excellent occlusion of all three aneurysms was obtained. One patient developed a distal middle cerebral artery clot, that was treated with intravenous aspirin, with minor neurological consequences. These early results show that the Comaneci device can be used to achieve good cerebral aneurysm occlusion. Vessel patency is maintained throughout the procedure with potential advantages over conventional balloon assisted coiling. PMID:26123460

  14. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huet, Nicolas, E-mail: nhuet@chu-grenoble.fr; Rodiere, Mathieu, E-mail: mrodiere@chu-grenoble.fr; Badet, Michel, E-mail: michel.badet@ch-chambery.fr

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  15. Successful Retreatment of Recurrent Intracranial Vertebral Artery Dissecting Aneurysms After Stent-Assisted Coil Embolization: A Self-Controlled Hemodynamic Analysis.

    PubMed

    Liu, Jian; Jing, Linkai; Zhang, Ying; Song, Ying; Wang, Yang; Li, Chuanhui; Wang, Yanmin; Mu, Shiqing; Paliwal, Nikhil; Meng, Hui; Linfante, Italo; Yang, Xinjian

    2017-01-01

    Intracranial vertebral artery dissecting aneurysms (VADAs) tend to recur despite successful stent-assisted coil embolization (SACE). Hemodynamics is useful in evaluating aneurysmal formation, growth, and rupture. Our aim was to evaluate the hemodynamic patterns of the recurrence of VADA. Between September 2009 and November 2013, all consecutive patients with recurrent VADAs after SACE in our institutions were enrolled. Recurrence was defined as recanalization and/or regrowth. We assessed the hemodynamic alterations in wall shear stress (WSS) and velocity after the initial SACE and subsequently after retreatment of the aneurysms that recurred. Five patients were included. After the initial treatment, 3 patients showed recanalization and 2 showed regrowth. In the 2 patients with regrowth, the 2 original aneurysms maintained complete occlusion; however, de novo aneurysm regrowth was confirmed near the previous site. Compared with 3 recanalized aneurysms, the completely occluded aneurysms showed high mean reductions in velocity and WSS after initial treatment (velocity, 77.6% vs. 57.7%; WSS, 74.2% vs. 52.4%); however, WSS remained high at the region near the previous lesion where the new aneurysm originated. After the second retreatment, there was no recurrence in any patient. Compared with the 3 aneurysms that recanalized, the 4 aneurysms that maintained complete occlusion showed higher reductions in velocity (62.9%) and WSS (71.1%). Our series indicated that hemodynamics might have an important role in recurrence of VADAs. After endovascular treatment, sufficient hemodynamic reduction in aneurysm dome, orifice, and parent vessel may be one of the key factors for preventing recurrence in VADAs. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. In Vitro Measurement of Tissue Integrity during Saccular Aneurysm Embolizations for Simulator-Based Training

    PubMed Central

    Tercero, C.; Ikeda, S.; Ooe, K.; Fukuda, T.; Arai, F.; Negoro, M.; Takahashi, I.; Kwon, G.

    2012-01-01

    Summary In the domain of endovascular neurosurgery, the measurement of tissue integrity is needed for simulator-based training and for the development of new intravascular instruments and treatment techniques. In vitro evaluation of tissue manipulation can be achieved using photoelastic stress analysis and vasculature modeling with photoelastic materials. In this research we constructed two types of vasculature models of saccular aneurysms for differentiation of embolization techniques according to the respect for tissue integrity measurements based on the stress within the blood vessel model wall. In an aneurysm model with 5 mm dome diameter, embolization using MicroPlex 10 (Complex 1D, with 4 mm diameter loops), a maximum area of 3.97 mm2 with stress above 1 kPa was measured. This area increased to 5.50 mm2 when the dome was touched deliberately with the release mechanism of the coil, and to 4.87 mm2 for an embolization using Micrusphere, (Spherical 18 Platinum Coil). In a similar way trans-cell stent-assisted coil embolization was also compared to human blood pressure simulation using a model of a wide-necked saccular aneurysm with 7 mm diameter. The area with stress above 1kPa was below 1 mm2 for the pressure simulation and maximized at 3.79 mm2 during the trans-cell insertion of the micro-catheter and at 8.92 mm2 during the embolization. The presented results show that this measurement system is useful for identifying techniques compromising tissue integrity, comparing and studying coils and embolization techniques for a specific vasculature morphology and comparing their natural stress variations such as that produced by blood pressure. PMID:23217635

  17. Endovascular MR-guided Renal Embolization by Using a Magnetically Assisted Remote-controlled Catheter System

    PubMed Central

    Lillaney, Prasheel V.; Yang, Jeffrey K.; Losey, Aaron D.; Martin, Alastair J.; Cooke, Daniel L.; Thorne, Bradford R. H.; Barry, David C.; Chu, Andrew; Stillson, Carol; Do, Loi; Arenson, Ronald L.; Saeed, Maythem; Wilson, Mark W.

    2016-01-01

    Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance and the specific areas where the MARC system can be improved. Materials and Methods In concordance with the Institutional Animal Care and Use Committee protocol, in vivo renal artery navigation and embolization were tested in three farm pigs (mean weight 43 kg ± 2 [standard deviation]) under real-time MR imaging at 1.5 T. The MARC catheter device was constructed by using an intramural copper-braided catheter connected to a laser-lithographed saddle coil at the distal tip. Interventionalists controlled an in-room cart that delivered electrical current to deflect the catheter in the MR imager. Contralateral kidneys were similarly embolized under x-ray guidance by using standard clinical catheters and guidewires. Changes in renal artery flow and perfusion were measured before and after embolization by using velocity-encoded and perfusion MR imaging. Catheter navigation times, renal parenchymal perfusion, and renal artery flow rates were measured for MR-guided and x-ray–guided embolization procedures and are presented as means ± standard deviation in this pilot study. Results Embolization was successful in all six kidneys under both x-ray and MR imaging guidance. Mean catheterization time with MR guidance was 93 seconds ± 56, compared with 60 seconds ± 22 for x-ray guidance. Mean changes in perfusion rates were 4.9 au/sec ± 0.8 versus 4.6 au/sec ± 0.6, and mean changes in renal flow rate were 2.1 mL/min/g ± 0.2 versus 1.9 mL/min/g ± 0.2 with MR imaging and x-ray guidance, respectively. Conclusion The MARC catheter system is feasible for renal artery catheterization and embolization under real-time MR imaging in vivo, and quantitative physiologic

  18. Endovascular MR-guided Renal Embolization by Using a Magnetically Assisted Remote-controlled Catheter System.

    PubMed

    Lillaney, Prasheel V; Yang, Jeffrey K; Losey, Aaron D; Martin, Alastair J; Cooke, Daniel L; Thorne, Bradford R H; Barry, David C; Chu, Andrew; Stillson, Carol; Do, Loi; Arenson, Ronald L; Saeed, Maythem; Wilson, Mark W; Hetts, Steven W

    2016-10-01

    Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance and the specific areas where the MARC system can be improved. Materials and Methods In concordance with the Institutional Animal Care and Use Committee protocol, in vivo renal artery navigation and embolization were tested in three farm pigs (mean weight 43 kg ± 2 [standard deviation]) under real-time MR imaging at 1.5 T. The MARC catheter device was constructed by using an intramural copper-braided catheter connected to a laser-lithographed saddle coil at the distal tip. Interventionalists controlled an in-room cart that delivered electrical current to deflect the catheter in the MR imager. Contralateral kidneys were similarly embolized under x-ray guidance by using standard clinical catheters and guidewires. Changes in renal artery flow and perfusion were measured before and after embolization by using velocity-encoded and perfusion MR imaging. Catheter navigation times, renal parenchymal perfusion, and renal artery flow rates were measured for MR-guided and x-ray-guided embolization procedures and are presented as means ± standard deviation in this pilot study. Results Embolization was successful in all six kidneys under both x-ray and MR imaging guidance. Mean catheterization time with MR guidance was 93 seconds ± 56, compared with 60 seconds ± 22 for x-ray guidance. Mean changes in perfusion rates were 4.9 au/sec ± 0.8 versus 4.6 au/sec ± 0.6, and mean changes in renal flow rate were 2.1 mL/min/g ± 0.2 versus 1.9 mL/min/g ± 0.2 with MR imaging and x-ray guidance, respectively. Conclusion The MARC catheter system is feasible for renal artery catheterization and embolization under real-time MR imaging in vivo, and quantitative physiologic

  19. EUS-guided gastroenterostomy: a multicenter study comparing the direct and balloon-assisted techniques.

    PubMed

    Chen, Yen-I; Kunda, Rastislav; Storm, Andrew C; Aridi, Hanaa Dakour; Thompson, Christopher C; Nieto, Jose; James, Theodore; Irani, Shayan; Bukhari, Majidah; Gutierrez, Olaya Brewer; Agarwal, Amol; Fayad, Lea; Moran, Robert; Alammar, Nuha; Sanaei, Omid; Canto, Marcia I; Singh, Vikesh K; Baron, Todd H; Khashab, Mouen A

    2018-05-01

    EUS-guided gastroenterostomy (EUS-GE) is a developing modality in the management of gastric outlet obstruction (GOO) with several technical approaches, including the direct and balloon-assisted techniques. The aim of this study was to compare the direct with the balloon-assisted modality while further defining the role of EUS-GE in GOO. This multicenter, retrospective study involved consecutive patients who underwent EUS-GE with the direct or balloon-assisted technique for GOO (January 2014 to October 2016). The primary outcome was technical success. Secondary outcomes were success (ability to tolerate at least a full fluid diet), procedure time, and rate/severity of adverse events (AEs). A total of 74 patients (44.6% women; mean age 63.0 ± 11.7 years) underwent EUS-GE for GOO (direct gastroenterostomy, n = 52; balloon-assisted gastroenterostomy, n = 22). GOO was of malignant and benign etiology in 66.2% and 33.8% of patients, respectively. Technical success was achieved in 94.2% of the direct and 90.9% of the balloon-assisted approach (P = .63). Mean procedure time was shorter with the direct technique (35.7 ± 32.1 minutes vs 89.9 ± 33.3 minutes, P < .001). The clinical success rate was 92.3% for the direct technique and 90.9% for the balloon-assisted modality (P = 1.00), with a mean time to oral intake of 1.32 ± 2.76 days. The AE rate was 6.8% with only 1 severe AE noted. Rate of AEs, postprocedure length of stay, need for reintervention, and survival were similar between the 2 groups. EUS-GE is effective and safe in the management of GOO. The direct technique may be the preferred method given its shorter procedure time when compared with the balloon-assisted approach. Prospective trials are needed to confirm these findings. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  20. Three-dimensional volume-rendering technique in the angiographic follow-up of intracranial aneurysms embolized with coils.

    PubMed

    Zhou, Bing; Li, Ming-Hua; Wang, Wu; Xu, Hao-Wen; Cheng, Yong-De; Wang, Jue

    2010-03-01

    The authors conducted a study to evaluate the advantages of a 3D volume-rendering technique (VRT) in follow-up digital subtraction (DS) angiography of coil-embolized intracranial aneurysms. One hundred nine patients with 121 intracranial aneurysms underwent endovascular coil embolization and at least 1 follow-up DS angiography session at the authors' institution. Two neuroradiologists independently evaluated the conventional 2D DS angiograms, rotational angiograms, and 3D VRT images obtained at the interventional procedures and DS angiography follow-up. If multiple follow-up sessions were performed, the final follow-up was mainly considered. The authors compared the 3 techniques for their ability to detect aneurysm remnants (including aneurysm neck and sac remnants) and parent artery stenosis based on the angiographic follow-up. The Kruskal-Wallis test was used for group comparisons, and the kappa test was used to measure interobserver agreement. Statistical analyses were performed using commercially available software. There was a high statistical significance among 2D DS angiography, rotational angiography, and 3D VRT results (X(2) = 9.9613, p = 0.0069) when detecting an aneurysm remnant. Further comparisons disclosed a statistical significance between 3D VRT and rotational angiography (X(2) = 4.9754, p = 0.0257); a high statistical significance between 3D VRT and 2D DS angiography (X(2) = 8.9169, p = 0.0028); and no significant difference between rotational angiography and 2D DS angiography (X(2) = 0.5648, p = 0.4523). There was no statistical significance among the 3 techniques when detecting parent artery stenosis (X(2) = 2.5164, p = 0.2842). One case, in which parent artery stenosis was diagnosed by 2D DS angiography and rotational angiography, was excluded by 3D VRT following observations of multiple views. The kappa test showed good agreement between the 2 observers. The 3D VRT is more sensitive in detecting aneurysm remnants than 2D DS angiography and

  1. Spontaneous Hemothorax in Neurofibromatosis Treated with Percutaneous Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arai, Kazunori; Sanada, Junichiro; Kurozumi, Akiko

    We evaluated the effectiveness of transcatheter arterial coil embolization therapy for the treatment of spontaneous hemothorax followed by aneurysm rupture in neurofibromatosis patients. Three patients were treated for massive hemothorax caused by arterial lesions associated with neurofibromatosis. Bleeding episodes were secondary to ascending cervical artery aneurysm and dissection of vertebral artery in 1 patient, and intercostal artery aneurysm with or without arteriovenous fistula in 2 patients. Patients were treated by transarterial coil embolization combined with chest drainage. In 1 patient, the ruptured ascending cervical artery aneurysm was well embolized but, shortly after the embolization, fatal hemorrhage induced by dissection ofmore » the vertebral artery occurred and the patient died. In the other 2 patients, the ruptured intercostal artery aneurysm was well embolized and they were successfully treated and discharged. Transcatheter arterial coil embolization therapy is an effective method for the treatment of spontaneous hemothorax followed by aneurysm rupture in neurofibromatosis patients.« less

  2. Coil occlusion of residual shunts after surgical closure of patent ductus arteriosus.

    PubMed

    Fujii, Yoko; Keene, Bruce W; Mathews, Kyle G; Atkins, Clarke E; Defrancesco, Teresa C; Hardie, Elizabeth M; Wakao, Yoshito

    2006-12-01

    OBJECTIVE; To describe use of coil embolization to occlude residual flow through a patent ductus arteriosus (PDA) after incomplete surgical ligation. Clinical study. Dogs (n=4) with continuous murmur after surgical ligation of PDA. After PDA ligation, residual ductal flow through the PDA was visible on color-flow Doppler examination and left ventricular end-diastolic diameter remained increased. Coil embolization by an arterial approach was performed to achieve complete occlusion of the PDA. Embolization coils were delivered without complications and hemodynamically successful occlusion was achieved. Doppler-visible flow resolved in 2 dogs within 3 months after embolization. Left ventricular end-diastolic diameter indexed to body weight decreased in all dogs. Transcatheter coil embolization appears to be a safe and minimally invasive procedure for complete occlusion of residual PDA flow after incomplete surgical ligation. Transcatheter coil embolization should be considered for correction of hemodynamically significant residual shunts in dogs that have incomplete PDA occlusion after open surgical ligation.

  3. Percutaneous Coil Embolization for the Treatment of a Giant Brachial Artery Pseudoaneurym in a Child.

    PubMed

    Yuksel, Ahmet; Nas, Omer Fatih; Kan, Irem Iris; Tok, Mustafa; Erdogan, Cuneyt

    2017-11-01

    Brachial artery pseudoaneurysm is a rare phenomenon. When a diagnosis of brachial artery pseudoaneurysm is established, early and appropriate treatment should be performed as soon as possible to prevent possible complications, such as hemorrhage, rupture, and upper limb and finger losses. Open surgical repair is usually the cornerstone of treatment; however, we here report a case of giant brachial pseudoaneurysm in a 2-year-old girl, which was successfully treated with percutaneous coil embolization. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Effect of air removal with extracorporeal balloon inflation on incidence of asymptomatic cerebral embolism during cryoballoon ablation of atrial fibrillation.

    PubMed

    Tokuda, Michifumi; Matsuo, Seiichiro; Kato, Mika; Sato, Hidenori; Oseto, Hirotsuna; Okajima, Eri; Ikewaki, Hidetsugu; Isogai, Ryota; Tokutake, Kenichi; Yokoyama, Kenichi; Narui, Ryohsuke; Tanigawa, Shin-Ichi; Yamashita, Seigo; Inada, Keiichi; Yoshimura, Michihiro; Yamane, Teiichi

    2017-09-01

    Asymptomatic cerebral embolism (ACE) is sometimes detected after cryoballoon ablation of atrial fibrillation. The removal of air bubbles from the cryoballoon before utilization may reduce the rate of ACE. This study aims to compare the incidence of ACE between a conventional and a novel balloon massaging method during cryoballoon ablation. Of 175 consecutive patients undergoing initial cryoballoon ablation of paroxysmal atrial fibrillation, 60 (34.3%) patients underwent novel balloon massaging with extracorporeal balloon inflation in saline water (group N) before the cryoballoon was inserted into the body. The remaining 115 (65.7%) patients underwent conventional balloon massaging in saline water while the balloon remained folded (group C). Of those, 86 propensity score-matched patients were included. The baseline characteristics were similar between the 2 groups. In group N, even after balloon massaging in saline water was carefully performed, multiple air bubbles remained on the balloon surface when the cryoballoon was inflated in all cases. Postprocedural cerebral magnetic resonance imaging detected ACE in 14.0% of all patients. The incidence of ACE was significantly lower in group N than in group C (4.7% vs 23.3%; P = .01). According to multivariable analysis, the novel method was the sole factor associated with the presence of ACE (odds ratio 0.161; 95% confidence interval 0.033-0.736; P = .02). Preliminary removal of air bubbles in heparinized saline water with extracorporeal balloon inflation reduced the incidence of ACE. Since conventional balloon massaging failed to remove air bubbles completely, this novel balloon massaging method should be recommended before cryoballoon utilization. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Protective Embolization of the Gastroduodenal Artery with a One-HydroCoil Technique in Radioembolization Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopez-Benitez, R., E-mail: Ruben.lopez@insel.ch; Hallscheidt, P.; Kratochwil, C.

    2013-02-15

    Protective occlusion of the gastroduodenal artery (GDA) is required to avoid severe adverse effects and complications in radioembolization procedures. Because of the expandable features of HydroCoils, our goal was to occlude the GDA with only one HydroCoil to provide particle reflux protection. Twenty-three subjects with unresectable liver tumors, who were scheduled for protective occlusion of the GDA before radioembolization therapy, were included. The primary end point was to achieve a proximal occlusion of the GDA with only one detachable HydroCoil. Evaluated parameters were duration of deployment, and early (during the intervention) and late (7-21 days) occlusion rates of GDA. Secondarymore » end points included complete duration of the intervention, amount of contrast medium used, fluoroscopy rates, and adverse effects. In all cases, the GDA was successfully occluded with only one HydroCoil. The selected diameter/length range was 4/10 mm in 2 patients, 4/15 mm in 6 patients, and 4/20 mm in 15 patients. HydroCoils were implanted, on average, 3.75 mm from the origin of the GDA (range 1.5-6.8 mm), with an average deployment time of 2:47 (median 2:42, range 2:30-3:07) min. In 21 (91%) of 23 patients, a complete occlusion of the GDA was achieved during the first 30 min after the coil implantation; however, in all patients, a late occlusion of the GDA was present after 6 to 29 days. No clinical or technical complications were reported. We demonstrated that occlusion of the GDA with a single HydroCoil is a safe procedure and successfully prevents extrahepatic embolization before radioembolization.« less

  6. Temporary balloon occlusion of the common hepatic artery for administration of yttrium-90 resin microspheres in a patient with patent hepatoenteric collaterals.

    PubMed

    Mahvash, Armeen; Zaer, Navid; Shaw, Colette; Chasen, Beth; Avritscher, Rony; Murthy, Ravi

    2012-02-01

    The most common serious complication of yttrium-90 ((90)Y) therapy is gastrointestinal ulceration caused by extrahepatic microsphere dispersion. The authors describe the use of a balloon catheter for temporary occlusion of the common hepatic artery to reverse hepatoenteric flow for lobar administration of resin microspheres when coil embolization of a retroportal artery was impossible. At 9 months after treatment, the patient had no gastrointestinal side effects and showed a partial response. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  7. Novel application of a balloon-anchoring technique for the realignment of a prolapsed pipeline embolization device: a technical report.

    PubMed

    Crowley, R Webster; Abla, Adib A; Ducruet, Andrew F; McDougall, Cameron G; Albuquerque, Felipe C

    2014-07-01

    Flow-diverting stents represent a substantial advancement in the treatment of cerebral aneurysms. They can, however, be associated with unique complications that may require management through adjunctive techniques. To present a technical report of a salvage technique used to realign a prolapsed Pipeline Embolization Device (PED) during the treatment of a giant internal carotid artery (ICA) aneurysm. A patient in his late 70s with an incidental giant supraclinoid ICA aneurysm presented for endovascular consideration. Treatment was planned using the PED. Following placement of the device there were two focal areas of incomplete expansion and balloon angioplasty was performed. This manipulation resulted in foreshortening of the distal aspect of the PED which caused the device to prolapse into the aneurysm. After multiple unsuccessful attempts to regain distal access, a salvage technique was attempted in which a balloon was inflated in the middle cerebral artery and, by applying traction, the PED was realigned with the parent artery. After the PED was realigned, direct distal catheter access was achieved and a second Pipeline device was deployed, successfully covering the aneurysm neck with resultant flow stasis. The patient had no postoperative issues and was discharged 2 days later without deficit. The balloon-anchoring technique was successfully used to realign a PED that had prolapsed into a giant ICA aneurysm. This maneuver prevented potentially disastrous complications and allowed the satisfactory completion of the aneurysm embolization. This represents a useful salvage technique that should be considered when encountering a prolapsed stent. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. Mycotic Celiac Artery Aneurysm Following Infective Endocarditis: Successful Treatment Using N-butyl Cyanoacrylate with Embolization Coils

    PubMed Central

    Ueda, Toshihiko; Koizumi, Jun; Cho, Yoshinori; Shimura, Shinichiro; Furuya, Hidekazu; Myojin, Kazunori; Okada, Kimiaki; Tanaka, Chiharu

    2012-01-01

    Mycotic celiac artery aneurysm following infective endocarditis is extremely rare and, to our knowledge, only four cases have been reported in the literature to date. We describe the case of a 60 year-old man who developed a mycotic aneurysm of the celiac artery, which was detected by computed tomography (CT) following an episode of infective endocarditis. He successfully underwent endovascular isolation and packing of the aneurysm using N-butyl cyanoacrylate (NBCA) with embolization coils. PMID:23555513

  9. Y-configuration double-stent-assisted coiling using two closed-cell stents for wide-neck basilar tip aneurysms.

    PubMed

    Jeon, Pyoung; Kim, Byung Moon; Kim, Dong Joon; Kim, Dong I K; Park, Keun Young

    2014-09-01

    This study aimed to evaluate clinical and angiographic outcomes of Y-configuration double-stent-assisted (Y-stent) coiling using two closed-cell stents for wide-necked basilar tip aneurysm (BTA). A total of 25 patients underwent Y-stent coiling using two closed-cell stents as a first-time treatment in 18 (3 ruptured) BTAs, retreatment in 2 BTAs and as a third treatment in 5 wide-necked BTAs. Clinical and angiographic outcomes were evaluated retrospectively. Treatment-related complications were three (12.0 %) thromboembolic infarctions due to two acute in-stent thromboses and one embolism. Twenty-two (88 %) patients had favorable outcomes (modified Rankin scale score [mRS], 0-2) during the follow-up period (mean, 30 months; range, 6-54 months). Two patients died: one from initial subarachnoid hemorrhage and the other from intracerebral hemorrhage due to underlying Moyamoya disease. Post-treatment angiograms showed complete occlusion in nine aneurysms, residual neck in 11 aneurysms and residual sac in five aneurysms. Follow-up angiograms were available at least once between 5 to 34 months (mean, 16 months) in 21 patients. Nineteen patients showed improved or stable states (complete occlusion, n = 17; residual neck, n = 2). Major recurrences occurred in two BTAs (9.5 %). Those two major recurrent aneurysms had been large-sized aneurysms at the initial coiling procedure. Both showed not only coil compaction but also progressive growth to giant-sized aneurysms and intra-aneurysmal thrombus formation at the Y-stent coiling as a third-time treatment. Y-stent coiling using two closed-cell stents is a safe and durable treatment option for wide-necked BTA, but may have limited efficacy for large/giant sized and thrombosed aneurysms.

  10. Endovascular rescue method for undesirably stretched coil.

    PubMed

    Cho, Jae Hoon

    2014-10-01

    Undesirable detachment or stretching of coils within the parent artery during aneurysm embolization can be related with thrombus formation, which can be caused occlusion of parent artery or embolic event(s). To escape from this situation, several rescue methods have been reported. A case with undesirably stretched coil in which another rescue method was used, is presented. When the stretched coil is still located in the coil delivery microcatheter, the stretched coil can be removed safely using a snare and a handmade monorail microcatheter. After a snare is lodged in the handmade monorail microcatheter, the snare is introduced over the coil delivery micorcatheter and located in the distal part of the stretched coil. After then, the handmade monorail microcatheter captures the stretched coil and the snare as one unit. This technique using a handmade monorail microcatheter and a snare can be a good rescue modality for the undesirably stretched coil, still remained within the coil delivery microcatheter.

  11. Endovascular Rescue Method for Undesirably Stretched Coil

    PubMed Central

    2014-01-01

    Undesirable detachment or stretching of coils within the parent artery during aneurysm embolization can be related with thrombus formation, which can be caused occlusion of parent artery or embolic event(s). To escape from this situation, several rescue methods have been reported. A case with undesirably stretched coil in which another rescue method was used, is presented. When the stretched coil is still located in the coil delivery microcatheter, the stretched coil can be removed safely using a snare and a handmade monorail microcatheter. After a snare is lodged in the handmade monorail microcatheter, the snare is introduced over the coil delivery micorcatheter and located in the distal part of the stretched coil. After then, the handmade monorail microcatheter captures the stretched coil and the snare as one unit. This technique using a handmade monorail microcatheter and a snare can be a good rescue modality for the undesirably stretched coil, still remained within the coil delivery microcatheter. PMID:25371791

  12. The nature of thrombosis induced by platinum and tungsten coils in saccular aneurysms.

    PubMed

    Byrne, J V; Hope, J K; Hubbard, N; Morris, J H

    1997-01-01

    To compare the efficacy and biocompatability of electrolytic and mechanically detachable embolization coils of two metal types. Experimental saccular aneurysms in pigs were used to assess embolization induced by platinum or tungsten coils. Longitudinal angiographic and histologic studies were performed on treated and untreated (control) aneurysms to compare thrombosis and cellular responses after embolization with electrolytically detachable platinum coils and with mechanically detached tungsten coils. Fewer tungsten than platinum coils were needed to induce thrombosis. The inflammatory response within the aneurysmal lumen was more florid in embolized aneurysms than in control aneurysms. No difference was found in the timing or extent of accumulation of eosinophils, lymphocytes, or polymorphs between the two coils used. Giant cell responses were more marked in treated aneurysms; tungsten coils more than platinum coils. The amount of collagen and fibrosis present increased over the study period and was similar in treated and control aneurysms. The coil type influenced the initial cellular response but had little effect on the rate or degree to which blood clot within the aneurysm was replaced by fibrous tissue.

  13. Long-term angiographic outcome of stent-assisted coiling compared to non-assisted coiling of intracranial saccular aneurysms

    PubMed Central

    Ozretić, David; Radoš, Marko; Pavliša, Goran; Poljaković, Zdravka

    2015-01-01

    Aim To compare angiographic result at long-term follow-up, and rates of progressive occlusion, recurrence, and retreatment of stent-assisted coiled (SAC) and non-assisted coiled (NAC) intracranial saccular aneurysms. Methods Retrospective evaluation of department records identified 260 patients with 283 saccular intracranial aneurysms who had long-term angiographic follow-up (more than 12 months) and were successfully treated with SAC (89 aneurysms) or NAC (194 aneurysms) at the University Hospital Center Zagreb from June 2005 to July 2012. Initial and control angiographic results in both groups were graded using Roy/Raymond scale, converted to descriptive terms, and the differences between them were evaluated for statistical significance. A multivariate analysis was performed to identify factors related to progression of aneurysm occlusion and recurrence at follow-up, and those related to aneurysm retreatment. Results There were more progressively occluded aneurysms in SAC group (38 of 89 aneurysms, 42.7%) than in NAC group (46 of 194, 23.7%) (P = 0.002), but there were no significant differences in the rates of recanalization, regrowth, and stable result. Multivariate logistic regression identified the use of stent as the most important factor associated with progressive occlusion (P = 0.015, odds ratio 2.22, 95% confidence interval 1.17-4.21), and large aneurysm size and posterior circulation location as most predictive of aneurysm recurrence and retreatment. Conclusion The use of stent is associated with delayed occlusion of initially incompletely coiled aneurysms during follow-up, but does not reduce the rate of recurrence and retreatment compared to coiling alone. Long-term angiographic follow-up is needed for both SAC and NAC aneurysms. PMID:25727039

  14. Cerebral Fat Embolism After Video-Assisted Thoracic Surgery.

    PubMed

    Scarpino, Maenia; Lanzo, Giovanni; Cappelli, Francesco; Moretti, Marco; Misuri, Gianni; Voltolini, Luca; Pistolesi, Massimo; Amantini, Aldo; Grippo, Antonello

    2016-11-01

    Cerebral fat embolism (CFE) is an uncommon disease occurring mainly after traumatic lower limb long bone fractures. A 64-year-old woman with pneumonia and bilateral pleural effusion underwent video-assisted thoracic surgery (VATS). After 3 days, the patient had an acute decrease in consciousness level followed by the onset of seizures and right hemiparesis. Brain computed tomography and magnetic resonance imaging showed findings suggestive of CFE. CFE occurring after an uncommon nontraumatic cause of fat embolism, such as VATS, is a rare clinical event whose diagnosis could be challenging. Neuroimaging can hasten diagnosis and prevent other unnecessary investigations and treatments. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. A Less Invasive Strategy for Ruptured Cerebral Aneurysms with Intracerebral Hematomas: Endovascular Coil Embolization Followed by Stereotactic Aspiration of Hematomas Using Urokinase

    PubMed Central

    Kim, Sang Heum; Kong, Min Ho

    2017-01-01

    Objective Aneurysm clipping and simultaneous hematoma evacuation through open craniotomy is traditionally recommended for ruptured cerebral aneurysms accompanied by intracerebral or intrasylvian hemorrhages. We report our experience of adapting a less invasive treatment strategy in poor-grade patients with intracerebral or intrasylvian hemorrhages associated with ruptured cerebral aneurysms, where the associated ruptured cerebral aneurysms were managed by endovascular coil embolization, followed by stereotactic aspiration of hematomas (SRH) using urokinase. Materials and Methods We retrospectively analyzed 112 patients with ruptured cerebral aneurysms. There were accompanying intracerebral or intrasylvian hemorrhages in 36 patients (32.1%). The most common site for these ruptured aneurysms was the middle cerebral artery (MCA) (n = 15; 41.6%). Endovascular coil embolization followed by SRH using urokinase was performed in 9 patients (25%). Results In these 9 patients, the most common site of aneurysms was the MCA (n = 3; 33.4%); the hematoma volume ranged from 19.24 to 61.68 mL. Four patients who were World Federation of Neurological Surgeons (WFNS) grade-IV on admission, achieved favorable outcomes (Glasgow Outcome Score [GOS] 4 or 5) at 6-months postoperatively. In the five patients who were WFNS grade-V on admission, one achieved a favorable outcome, whereas 4 achieved GOS scores of 2 or 3, 6-months postoperatively. There was no mortality. Conclusion If immediate hematoma evacuation is not mandated by clinical or radiological signs of brain herniation, a less invasive strategy, such as endovascular coil embolization followed by SRH using urokinase, may be a good alternative in poor-grade patients with intracerebral or intrasylvian hemorrhages associated with ruptured cerebral aneurysms. PMID:29152466

  16. Radiation exposure, and procedure and fluoroscopy times in endovascular treatment of intracranial aneurysms: a methodological comparison.

    PubMed

    Cheung, Nicholas K; Boutchard, Michelle; Carr, Michael W; Froelich, Jens J

    2018-01-09

    Limited data are available for radiation exposure, and procedure and fluoroscopy times in neuroendovascular treatment (NET) strategies. This study establishes and compares related parameters between coil embolization (COIL), balloon assisted coil embolization (BAC), stent assisted coil embolization (SAC), and flow diverting technology (FDT) in NET of intracranial aneurysms. Between 2010 and 2017, 249 consecutive intracranial aneurysms underwent NET at a single center, all performed by the same operator. Dose area products (DAP), and procedure and fluoroscopy times were recorded and compared between COIL, BAC, SAC, and FDT techniques. Differences in parameters between cohorts were analyzed for significance using the Mann-Whitney U test, unpaired t test and χ 2 test. Additional subgroup analysis was performed for emergency and elective cases. 83 aneurysms were treated with COIL (33%), 72 with BAC (29%), 61 with SAC (25%), and 33 with FDT (13%). Baseline characteristics were largely similar within these groups (P>0.05). Among COIL, BAC, and FDT cohorts, no significant difference was found for mean DAP, or procedure and fluoroscopy times (P>0.05). However, compared with all other cohorts, SAC was associated with a significantly higher DAP and longer procedure and fluoroscopy times (P<0.005). No significant difference was recorded for emergency and elective case subgroups. Compared with other NET strategies, SAC was associated with a significantly higher DAP, and longer procedure and fluoroscopy times. This study provides an initial dataset regarding radiation exposure, and procedure and fluoroscopy times for common NET, and may assist ALARA (As Low As Reasonably Achievable) principles to reduce radiation risks. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Embolization of the Systemic Arterial Supply via a Detachable Silicon Balloon in a Child with Scimitar Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sahin, Sinan; Celebi, Ahmet; Yalcin, Yalim

    2005-04-15

    Scimitar syndrome is a rare congenital disorder. It is characterized by partial or total abnormal venous drainage of the right lung into the inferior vena cava, which is often associated with anomalous systemic arterial supply to the right lung, congenital cardiac anomalies, hypoplasia of the right lung and bronchial anomalies. Symptoms depend on the degree of the shunt and severity of the associated anomalies, which determine the treatment. We present a 6-year-old boy who was diagnosed as having the adult form of scimitar syndrome during evaluation for recurrent pulmonary infections, and underwent embolization with a detachable silicon balloon of themore » anomalous systemic arterial supply from the abdominal aorta to the right lower lung lobe. Successful elective surgery was performed 6 months later, in which right pulmonary veins were directed to the left atrium using a Gore-Tex patch by creating an intra-atrial tunnel. The patient has been symptom-free period during 6 months of follow-up, which supports the idea that recurrent pulmonary infections can be eliminated by embolization of the anomalous arterial supply.« less

  18. Transarterial treatment of direct carotico-cavernous fistulas with coils and Onyx.

    PubMed

    Ramalingaiah, Arvinda Hanumanthapura; Prasad, Chandrajit; Sabharwal, Paramveer Singh; Saini, Jitender; Pandey, Paritosh

    2013-10-01

    The purpose of this study was to evaluate the role of combination of liquid embolic agent ethylene vinyl alcohol copolymer (Onyx) and detachable coils in the treatment of direct carotico-cavernous fistulas (CCFs). We prospectively collected clinical and radiological data of all patients who underwent embolization of direct CCFs at our institution over a period of 21 months. The clinical parameters, angioarchitecture, presence of cortical venous reflux, volume of Onyx used, number of coils used, extent of embolization and complications were recorded. A total of 21 consecutive patients (18 men and 3 women, 14 to 48 years) with direct CCF underwent embolization with a combination of coils and Onyx. Embolization was done through the arterial route in all cases. Complete obliteration of the fistula was achieved in 19 of 21 cases. Cast embolization in middle cerebral artery occurred in one patient; however, the cast was completely retrieved with Solitaire device, and the patient did not have any neurological deficit. All completely treated patients reported relief of symptoms at varying intervals. At 6-month follow-up, none of the patients with complete occlusion of the fistula showed any recurrence. The adjuvant use of Onyx with detachable coils in direct CCF through the arterial route is a safe and effective method for embolization with immediate and complete occlusion of the fistula. To the best of our knowledge, this is the first case series of demonstration of arterial use of Onyx with coils in the treatment of direct CCFs.

  19. Renal Artery Embolization - A First Line Treatment Option For End-Stage Hydronephrosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitra, Kakali; Prabhudesai, Vikramaditya; James, R. Lester

    Conventionally poorly functioning hydronephrotic kidneys have been removed if they are symptomatic. In our unit, patients are offered renal artery embolization as an alternative treatment option. Patients and Methods: Fifteen patients (11 male, 4 female) with a mean age of 32.9 yr (20-51 yrs) have undergone renal artery embolization for symptomatic hydronephrosis with poor function. Mean follow-up was 64.13 weeks (range 14-200). All patients had loin pain and hydronephrosis. Twelve patients had primary pelvi-ureteric junction obstruction (PUJO). Two patients had poorly functioning hydronephrotic kidneys secondary to chronic calculous obstruction. One patient had chronic pain in an obstructed but reasonably functioningmore » kidney following a previous pyeloplasty for PUJO which demanded intervention. Mean split function on renography was 11% (range 0-46%). Selective renal artery embolization was carried out under antibiotic cover using a 7 Fr balloon occlusion catheter and absolute alcohol, steel coils, and polyvinyl alcohol particles.Results: Nine patients developed post-embolization syndrome of self-limiting pain and pyrexia with no evidence of sepsis. One patient required readmission with this condition. One patient developed a hematoma at the puncture site. Mean hospital stay was 2.3 days. Fourteen patients are happy with the result and are completely pain free. One patient has minor discomfort but is delighted with the result. Nine patients have had follow-up ultrasound confirming resolution of the hydronephrosis. Conclusion: Renal artery embolization is an effective, safe, well-tolerated minimally invasive treatment option in end-stage hydronephrosis and we routinely offer it as an alternative to nephrectomy.« less

  20. Results of coil closure of patent ductus arteriosus using a tapered tip catheter for enhanced control.

    PubMed

    Devanagondi, Rajiv; Latson, Larry; Bradley-Skelton, Sharon; Prieto, Lourdes

    2016-08-01

    This article describes the efficacy and embolization rates of coil delivery via modified vertebral catheter (MVC) for patent ductus arteriosus (PDA) closure. Various techniques have been devised to enhance coil control and prevent embolization during PDA closure. Since 1995, they have delivered coils via tapered vertebral catheters for improved coil control. Catheterization reports, angiograms, and echocardiograms were reviewed for patients with PDA occlusion via MVC from 2001 to 2014. Residual shunting was determined by angiography and echocardiogram within 24 hr post-procedure. Procedural success was defined as ≤ trivial angiographic and echocardiographic shunt, and no aortic nor LPA obstruction, after final coil delivery. About 125 coil occlusions were attempted in 103 patients. Minimal PDA diameter was 2 (0.6-6) mm. Four coils were removed with a snare/bioptome due to aortic/LPA obstruction following release. Seven were malpositioned while still held by the MVC of which three embolized while attempting withdrawal. Five embolized after full release from the MVC. The embolization rate was 6.4%. Embolizations were more likely in PDAs ≥ 2.5 mm (P < 0.05). Ultimately, 98/103 PDAs were occluded using the MVC. No patient had greater trivial residual shunt or aortic/LPA obstruction for an overall success rate of 95%. For PDAs < 2.5 mm the success rate was 97%. Coil delivery via MVC was safe and effective for small PDAs. While fully controlled release and retrieval devices are now available for PDA closure with lower embolization rates, coil occlusion by MVC should still be considered for small PDAs, especially in resource limited regions. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. Combined Endovascular Treatment with Distal Radial Artery Coil Embolization and Angioplasty in Steal Syndrome Associated with Forearm Dialysis Fistula.

    PubMed

    Tercan, Fahri; Koçyiğit, Ali; Güney, Bünyamin

    2016-09-01

    The present study was performed to define the results of the endovascular treatment with angioplasty and distal radial artery embolization in ischemic steal syndrome associated with forearm arteriovenous accesses. The cases referred to our interventional radiology unit with symptoms and physical examination findings suggestive of ischemic steal syndrome were retrospectively evaluated first by Doppler ultrasonography, and then by angiography. Cases with proximal artery stenosis were applied angioplasty, and those with steal syndrome underwent coil embolization to distal radial artery. Of 589 patients who underwent endovascular intervention for dialysis arteriovenous fistulae (AVF)-associated problems, 6 (1.01 %) (5 female, 1 males; mean age 62 (range 41-78) with forearm fistula underwent combined endovascular treatment for steal syndrome. In addition to steal phenomenon, there were stenosis and/or occlusion in proximal radial and/or ulnar artery in 6 patients concurrently. Embolization of distal radial artery and angioplasty to proximal arterial stenoses were performed in all patients. Ischemic symptoms were eliminated in all patients and the AVF were in use at the time of study. In one patient, ischemic symptoms recurring 6 months later were alleviated by repeat angioplasty of ulnar artery. In palmar arch steal syndrome affecting forearm fistulae, combined distal radial embolization and angioplasty is also an effective treatment method in the presence of proximal radial and ulnar arterial stenoses and occlusions.

  2. Emergent Embolization of Arterial Bleeding after Vacuum-Assisted Breast Biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischman, Aaron M., E-mail: aaron.fischman@mountsinai.org; Epelboym, Yan, E-mail: yan.epelboym@mssm.edu; Siegelbaum, Robert H., E-mail: rhsiegelbaum@gmail.com

    2012-02-15

    Vacuum-assisted core breast biopsy has become important in evaluating patients with suspicious breast lesions. It has proven to be a relatively safe procedure that in rare cases can result in vascular complications. These are the first reported cases of transcatheter embolization of uncontrolled breast hemorrhage after vacuum-assisted breast biopsy. With increased use of biopsy and larger-gauge devices, breast imaging groups may consider embolotherapy as a safe alternative for treatment of hemorrhage in a select group of patients.

  3. Endovascular coil embolization of aneurysm neck for the treatment of ruptured intracranial aneurysm with bleb formation

    PubMed Central

    Wan, Jun; Gu, Weijin; Zhang, Xiaolong; Geng, Daoying; Lu, Gang; Huang, Lei; Zhang, Lei; Ge, Liang; Ji, Lihua

    2014-01-01

    Background Ruptured intracranial aneurysm (ICA) with bleb formation (RICABF) is a special type of ruptured ICA. However, the exact role and effectiveness of endovascular coil embolization (ECE) in RICABF is unknown. We aimed to investigate the effectiveness and safety of ECE of aneurysm neck for RICABF treatment. Material/Methods We retrospectively assessed consecutive patients who were hospitalized in our endovascular intervention center between October 2004 and May 2012. Overall, 86 patients underwent ECE of aneurysm neck for 86 RICABF. Treatments outcomes included secondary rupture/bleeding rate, aneurysm neck embolization rate, residual/recurrent aneurysm, intraoperative incidents, and post-embolization complications, as well as improvements in the Glasgow outcome scale (extended) (GOS-E). Results Complete occlusion was achieved in 72 aneurysms (72/86, 83.7%), while 12 aneurysms (12/86, 14.0%) had a residual neck, and 2 aneurysms (2/86, 2.3%) had a residual aneurysm. The postoperative GOS-E was 3 in 3 patients (3.5%), 4 in 10 patients (11.6%), and 5 in 73 patients (84.9%). Follow-up angiography was performed in all patients (mean 9.0 months, interquartile range of 9.0). Recurrence was found in 3 patients (3/86, 3.5%). No aneurysm rupture or bleeding was reported. Conclusions Our mid-term follow-up study showed that ECE of aneurysm neck was an effective and safe treatment modality for RICABF. The long-term effectiveness and safety of this interventional radiology technique need to be investigated in prospective and comparative studies. PMID:24986761

  4. Safety of Radioembolization with {sup 90}Yttrium Resin Microspheres Depending on Coiling or No-Coiling of Aberrant/High-Risk Vessels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paprottka, P. M., E-mail: philipp.paprottka@med.lmu.de, E-mail: philipp.paprottka@med.uni-muenchen.de; Paprottka, K. J., E-mail: karolin.paprottka@med.lmu.de; Walter, A., E-mail: alexandra.Walter@campus.lmu.de

    2015-08-15

    PurposeTo evaluate the safety of radioembolization (RE) with {sup 90}Yttrium ({sup 90}Y) resin microspheres depending on coiling or no-coiling of aberrant/high-risk vessels.Materials and MethodsEarly and late toxicity after 566 RE procedures were analyzed retrospectively in accordance with the National Cancer Institute’s Common Terminology Criteria for Adverse Events (CTCAE v3.0). For optimal safety, aberrant vessels were either coil embolized (n = 240/566, coiling group) or a more peripheral position of the catheter tip was chosen to treat right or left liver lobes (n = 326/566, no-coiling group).ResultsClinically relevant late toxicities (≥Grade 3) were observed in 1 % of our overall cohort. The no-coiling group had significantlymore » less “any” (P = 0.0001) or “clinically relevant” (P = 0.0003) early toxicity. There was no significant difference (P > 0.05) in delayed toxicity in the coiling versus the no-coiling group. No RE-induced liver disease was noted after all 566 procedures.ConclusionRE with {sup 90}Y resin microspheres is a safe and effective treatment option. Performing RE without coil embolization of aberrant vessels prior to treatment could be an alternative for experienced centers.« less

  5. Crural artery traumatic injuries: treatment with embolization.

    PubMed

    Lopera, Jorge E; Suri, Rajeev; Cura, Marco; Kroma, Ghazwan; El-Merhi, Fadi

    2008-01-01

    The purpose of this paper is to report our experience with the endovascular treatment of crural arterial injuries using transcatheter and direct embolization techniques. A total of eight consecutive patients have been treated during a 7-year period. Six males and two females, mean age 32 years (range, 15-56 years), presented with penetrating trauma to the lower extremities. Mechanisms of injuries were stab wounds in six patients, gun shot wound in one patient, and iatrogenic injury in one patient. Five patients presented with acute trauma, while three patients presented with delayed injuries. Crural arterial injuries encountered included pseudoaneurysms with arteriovenous fistulas (n = 6), pseudoaneurysms with vessel transections (n = 2), and pseudoaneurysm (n = 1). Proximal and distal embolization with coils was used in three cases, proximal embolization with coils in three cases, percutaneous thrombin injection in one case, and liquid n-butyl cyanoacrylate in one case. Complete exclusion of the lesions was accomplished by sacrifice of one crural vessel in seven cases and of two crural vessels in one case. Two cases of delayed injuries required combined coil and liquid embolization techniques for lesion exclusion. A minor complication (groin hematoma) occurred in one patient, no distal ischemia was seen, and no amputations were required. Mean follow-up was 61 days (range, 1-180 days). One pseudoaneurysm treated with thrombin injection recurred and required surgical excision. We conclude that transcatheter embolization alone or in combination with different endovascular techniques is useful in the treatment of traumatic crural vessel injuries.

  6. Crural Artery Traumatic Injuries: Treatment with Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopera, Jorge E., E-mail: Lopera@uthscssa.edu; Suri, Rajeev; Cura, Marco

    The purpose of this paper is to report our experience with the endovascular treatment of crural arterial injuries using transcatheter and direct embolization techniques. A total of eight consecutive patients have been treated during a 7-year period. Six males and two females, mean age 32 years (range, 15-56 years), presented with penetrating trauma to the lower extremities. Mechanisms of injuries were stab wounds in six patients, gun shot wound in one patient, and iatrogenic injury in one patient. Five patients presented with acute trauma, while three patients presented with delayed injuries. Crural arterial injuries encountered included pseudoaneurysms with arteriovenous fistulasmore » (n = 6), pseudoaneurysms with vessel transections (n = 2), and pseudoaneurysm (n = 1). Proximal and distal embolization with coils was used in three cases, proximal embolization with coils in three cases, percutaneous thrombin injection in one case, and liquid n-butyl cyanoacrylate in one case. Complete exclusion of the lesions was accomplished by sacrifice of one crural vessel in seven cases and of two crural vessels in one case. Two cases of delayed injuries required combined coil and liquid embolization techniques for lesion exclusion. A minor complication (groin hematoma) occurred in one patient, no distal ischemia was seen, and no amputations were required. Mean follow-up was 61 days (range, 1-180 days). One pseudoaneurysm treated with thrombin injection recurred and required surgical excision. We conclude that transcatheter embolization alone or in combination with different endovascular techniques is useful in the treatment of traumatic crural vessel injuries.« less

  7. Pulmonary Angiography and Embolization for Severe Hemoptysis Due to Cavitary Pulmonary Tuberculosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanyika, Charles; Corr, Peter; Royston, Duncan

    1999-11-15

    Purpose: To identify the role of pulmonary angiography in the diagnosis and treatment of severe hemoptysis due to cavitary pulmonary tuberculosis. Methods: Selective pulmonary angiography was performed on eight patients with severe hemoptysis uncontrolled by previous bronchial and systemic arterial embolization. Results: Three (38%) patients had Rasmussen aneurysms, which were successfully embolized with steel coils. Five patients demonstrated pulmonary arterial hypoperfusion in the diseased lung. Conclusions: We recommend pulmonary angiography in cavitary tuberculous patients with severe hemoptysis who do not respond to systemic arterial embolization. Rasmussen aneurysms are effectively treated by steel coil occlusion.

  8. Carotid and vertebral artery sacrifice with a combination of Onyx and coils: technical note and case series.

    PubMed

    Chalouhi, Nohra; Starke, Robert M; Tjoumakaris, Stavropoula I; Jabbour, Pascal M; Gonzalez, L Fernando; Hasan, David; Rosenwasser, Robert H; Dumont, Aaron S

    2013-08-01

    Permanent vessel sacrifice has become a routine for the management of aneurysms, pseudoaneurysms, tumors, and carotid blowouts. The purpose of this study is to describe a new technique for carotid and vertebral artery sacrifice using a combination of Onyx and coils and to assess its feasibility, safety, and efficacy. The technique consists of deploying a few coils in the parent vessel under proximal flow arrest followed by Onyx embolization directly into the coil mass. A total of 41 patients underwent carotid/vertebral artery sacrifice using this technique in our institution. A total of 26 internal carotid arteries and 15 vertebral arteries were treated. In all but one patient, a balloon test occlusion was performed prior to permanent arterial sacrifice. The mean number of coils used was 6.8 (range, 2-19). The total volume of Onyx used was 1.3 ml on average (range, 0.2-5.2 ml). All 41 (100%) parent arteries were successfully occluded. No distal migration of Onyx or coils was noted. Periprocedural complications occurred in 14.6% (6/41) of cases causing permanent morbidity in 7.3% (3/41). No patient developed a recurrence during the follow-up period (mean, 14 months). Parent vessel sacrifice with a combination of Onyx and coils appears to be feasible, safe, and effective and may be an alternative to the traditional deconstruction technique with coils alone. The risk of thromboembolism exists with this technique, but there were no instances of Onyx migration.

  9. Antigravity ESD - double-balloon-assisted underwater with traction hybrid technique.

    PubMed

    Sharma, Sam K; Hiratsuka, Takahiro; Hara, Hisashi; Milsom, Jeffrey W

    2018-06-01

     Complex colorectal polyps or those positioned in difficult anatomic locations are an endoscopic therapeutic challenge. Underwater endoscopic submucosal dissection (UESD) is a potential technical solution to facilitate efficient polyp removal. In addition, endoscopic tissue retraction has been confined to limited methods of varying efficacy and complexity. The aim of this study was to evaluate the efficiency of a unique UESD technique for removing complex polyps using double-balloon-assisted retraction (R).  Using fresh ex-vivo porcine rectum, 4-cm polyps were created using electrosurgery and positioned at "6 o'clock" within an established ESD model. Six resections were performed in each group. Underwater techniques were facilitated using a novel double-balloon platform (Dilumen, Lumendi, Westport, Connecticut, United States).  UESD-R had a significantly shorter total procedural time than cap-assisted ESD and UESD alone (24 vs. 58 vs. 56 mins). UESD-R produced a dissection time on average of 5 minutes, attributed to the retraction provided. There was also a subjective significant reduction in electrosurgical smoke with the underwater techniques contributing to improved visualization.  Here we report the first ex-vivo experience of a unique double-balloon endoscopic platform optimized for UESD with tissue traction capability. UESD-R removed complex lesions in significantly shorter time than conventional means. The combined benefits of UESD and retraction appeared to be additive when tackling complex polyps and should be studied further.

  10. Combined Endovascular Treatment with Distal Radial Artery Coil Embolization and Angioplasty in Steal Syndrome Associated with Forearm Dialysis Fistula

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tercan, Fahri, E-mail: ftercan@yahoo.com; Koçyiğit, Ali, E-mail: alkoc@yahoo.com; Güney, Bünyamin

    PurposeThe present study was performed to define the results of the endovascular treatment with angioplasty and distal radial artery embolization in ischemic steal syndrome associated with forearm arteriovenous accesses.MethodThe cases referred to our interventional radiology unit with symptoms and physical examination findings suggestive of ischemic steal syndrome were retrospectively evaluated first by Doppler ultrasonography, and then by angiography. Cases with proximal artery stenosis were applied angioplasty, and those with steal syndrome underwent coil embolization to distal radial artery.ResultsOf 589 patients who underwent endovascular intervention for dialysis arteriovenous fistulae (AVF)-associated problems, 6 (1.01 %) (5 female, 1 males; mean age 62 (rangemore » 41–78) with forearm fistula underwent combined endovascular treatment for steal syndrome. In addition to steal phenomenon, there were stenosis and/or occlusion in proximal radial and/or ulnar artery in 6 patients concurrently. Embolization of distal radial artery and angioplasty to proximal arterial stenoses were performed in all patients. Ischemic symptoms were eliminated in all patients and the AVF were in use at the time of study. In one patient, ischemic symptoms recurring 6 months later were alleviated by repeat angioplasty of ulnar artery.ConclusionIn palmar arch steal syndrome affecting forearm fistulae, combined distal radial embolization and angioplasty is also an effective treatment method in the presence of proximal radial and ulnar arterial stenoses and occlusions.« less

  11. Feasibility and Safety of Distal and Proximal Combined Endovascular Approach with a Balloon-Guiding Catheter for Subclavian Artery Total Occlusion.

    PubMed

    Yamamoto, Taiki; Ohshima, Tomotaka; Ishikawa, Kojiro; Goto, Shunsaku; Tamari, Yosuke

    2017-04-01

    Symptomatic subclavian artery total occlusion is widely treated with an endovascular procedure that often results in distal vertebral artery embolism. Therefore, protection devices are important. Establishing a filter or balloon device in the vertebral artery can protect against this distal embolism. However, the use of embolic protection devices is not easy, and it makes the procedure more complicated. Here, we report a case of symptomatic subclavian artery total occlusion that was treated successfully with a balloon-guiding catheter and the pull-through technique. A 67-year-old man developed intermittent motor weakness in his left arm. Aortic angiography demonstrated a complete occlusion of the left proximal subclavian artery and a retrograde flow through the left vertebral artery to the distal brachial artery. In this case, we used a balloon-guiding catheter and the pull-through technique to prevent distal embolism. The balloon-guiding system was useful not only for embolic protection but also for scaffold during excavation and for the centering effect against invisible vessels. The pull-through technique enabled our devices to deliver easily and smoothly. The patient was treated successfully without complications. The distal and proximal combined endovascular treatment with a transbrachial balloon-guiding catheter is a beneficial treatment option for patients with subclavian artery total occlusion. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Cerebral Arterial Gas Embolism During Upper Endoscopy.

    PubMed

    Eoh, Eun J; Derrick, Bruce; Moon, Richard

    2015-09-15

    Arterial gas embolism can be caused by direct entry of gas into systemic arteries or indirectly by venous-to-arterial shunting. Although arterial gas embolism is rare, most documented cases are iatrogenic, resulting from the entry of gas during procedures that involve direct vascular cannulation or intracavitary air insufflation. Of the 18 identified case reports of air embolism during endoscopy, 11 cases describe findings of cerebral arterial gas embolism during upper endoscopy. Only 1 of these occurred during endoscopic balloon dilation of an esophageal stricture. We report a rare case of cerebral arterial gas embolism in a 64-year-old woman, which occurred during endoscopic dilation of an esophageal stricture and was subsequently treated with hyperbaric oxygen therapy. In this case report, we explore the possible etiologies, clinical workup, and therapeutic management of cerebral artery gas embolisms. Hyperbaric oxygen therapy is the treatment of choice for cerebral arterial gas embolism, with earlier treatments resulting in better outcomes.

  13. Comparison of Two Endovascular Steerable Robotic Catheters for Percutaneous Robot-Assisted Fibroid Embolization.

    PubMed

    Del Giudice, C; Pellerin, O; Nouri Neville, M; Amouyal, G; Fitton, I; Leré-Déan, C; Sapoval, M

    2018-03-01

    To compare outcomes of percutaneous robot-assisted uterine fibroid embolization (UFE) using two different endovascular robotic catheters. Twenty-one patients with a symptomatic uterine fibroid were prospectively enrolled in a single-center study to be treated with a percutaneous robot-assisted embolization using the Magellan system. Fourteen patients were treated using a first generation steerable robotic catheter, version 1.0 (group 1), and seven were treated using the new version 1.1 (group 2). Demographic, pathologic, and procedural variables were recorded. Dose Area Product (DAP) and physician equivalent doses were registered for each procedure. Procedural related complications and clinical midterm outcomes were also evaluated. Successful robot-assisted UFE was obtained in eight patients (57.1%) in group 1 and 7 patients (100%) in group 2 (p = 0.01). A successful robot-assisted catheterization of the internal iliac artery anterior branch was performed in all patients of both groups. Median selective target vessel catheterization time was 21.0 ± 12.8 vs 13.4 ± 7 min (p = 0.04) and total fluoroscopy time was 30.3 ± 11.2 vs 19.3 ± 5.9 min, respectively, in group 1 and 2. Mean DAP decreased from 18472.6 ± 15622 to 5469.1 ± 4461.0 cGy·cm 2 (p = 0.04). All patients obtained a symptoms relief at 6 months follow-up. Robot-assisted uterine fibroid embolization is safe and effective. New version of steerable robotic catheter allows performing a faster procedure without related adverse events compared to old version.

  14. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon.

    PubMed

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2013-03-22

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM.

  15. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon.

    PubMed

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2014-04-01

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM.

  16. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon

    PubMed Central

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2013-01-01

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM. PMID:23524491

  17. Coil Embolization of Pancreaticoduodenal Artery Aneurysms Associated with Celiac Artery Stenosis: Report of Three Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikeda, Osamu, E-mail: osamu-3643ik@do9.enjoy.ne.jp; Tamura, Yoshitaka; Nakasone, Yutaka

    2007-06-15

    Aneurysms of the pancreaticoduodenal artery are rare. Degeneration of pancreaticoduodenal arcade vessels due to these aneurysms is associated with celiac artery stenosis or occlusion. Untreated lesions enlarge progressively and may rupture spontaneously. As the location of aneurysms of pancreaticoduodenal arcade vessels renders their surgical extirpation a challenge, we examined whether endovascular techniques offer a treatment alternative. We report on 3 patients with aneurysms of the pancreaticoduodenal arcade vessels and concomitant celiac artery stenosis/occlusion due to compression by the median arcuate ligament or chronic pancreatitis. All patients were treated by percutaneous coil embolization of the aneurysm. The aneurysmal sac was successfullymore » excluded and the native circulation was preserved. Endovascular surgery can be used to treat these aneurysms safely and permits retention of the native circulation.« less

  18. Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Platinum-Fibered Microcoils with the Amplatzer Vascular Plug II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pech, Maciej, E-mail: maciej.pech@med.ovgu.de; Kraetsch, Annett; Wieners, Gero

    2009-05-15

    The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aortamore » and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp

  19. Clinical efficacy and safety of transcatheter embolization for vascular complications after percutaneous nephrolithotomy.

    PubMed

    Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Sönmez, Mehmet Giray; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet

    2017-12-01

    Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19-75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3-18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization.

  20. Transjugular Intrahepatic Portosystemic Shunt Creation and Variceal Coil or Plug Embolization Ineffectively Attain Gastric Variceal Decompression or Occlusion: Results of a 26-Patient Retrospective Study.

    PubMed

    Lakhoo, Janesh; Bui, James T; Lokken, R Peter; Ray, Charles E; Gaba, Ron C

    2016-07-01

    To assess the efficacy of transjugular intrahepatic portosystemic shunt (TIPS) creation with or without variceal coil and/or plug embolization in decompressing or occluding gastric varices (GVs). In this retrospective study, 78 patients with GV bleeding who underwent TIPS creation with or without embolotherapy with metallic coils and/or plugs from 1999 to 2014 were identified. Individuals who had a bare-metal TIPS and/or lacked post-TIPS imaging or endoscopic follow-up were excluded. The final cohort included 26 patients (16 men; median age, 54 y; median Model for End-stage Liver Disease score, 16). Variceal types, supplying vessels, and postprocedure GV patency on cross-sectional imaging or endoscopy were assessed. The primary study outcome measure was GV patency rate as a surrogate for efficacy of TIPS creation with or without embolization. GVs included gastroesophageal varix types 1 (n = 10) and 2 (n = 2), isolated GV types 1 (n = 4) and 2 (n = 2), and unspecified (n = 8). TIPS creation resulted in a median final portosystemic pressure gradient of 7 mm Hg. Multiple GV-supplying vessels (left/posterior/short gastric veins) were present in 65% of patients (n = 17). Embolization was performed in 69% (n = 18). Thirteen, four, and nine patients had imaging, endoscopic, or both imaging/endoscopic follow-up. GV patency rate was 65% (n = 17; 61%/75% with/without embolization) at a median of 128.5 days (range, 1-1,295 d) after TIPS creation. Incidence of recurrent bleeding was 27% (n = 7), and the 90-day mortality rate was 15% (n = 4). In this study, most GVs showed persistent patency despite TIPS decompression and variceal embolization, and the incidence of recurrent bleeding was high. The findings suggest suboptimal efficacy for GVs, and indicate a need for study of alternative or adjunctive approaches to GV treatment, such as chemical obliteration. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  1. Endovascular Patch Embolization for Blood Blister-Like Aneurysms in Dorsal Segment of Internal Carotid Artery.

    PubMed

    Hao, Xudong; Li, Guilin; Ren, Jian; Li, Jingwei; He, Chuan; Zhang, Hong-Qi

    2018-05-01

    Blood blister-like aneurysms (BBAs) in the dorsal segment of the internal carotid artery are fragile and difficult to treat, and the optimal treatment for BBAs is still controversial. We report clinical and angiographic results with procedural details for the treatment of BBA by using the endovascular patch embolization method. We retrospectively reviewed patients who presented with subarachnoid hemorrhage caused by internal carotid artery-BBAs and were treated with the endovascular patch embolization method in our center from October 2011 to March 2015. Clinical records, angiographic findings, procedural details, and follow-up results are reported in this study. Eight patients were enrolled in this study. All patients were treated with the endovascular patch embolization method. The key points of this method are step-by-step stent deployment and swaying of the microcatheter to coil the aneurysm sac and the wedge-shaped space between the stent and parent artery and, thereby, in the aneurysm sac and parent artery around the aneurysm neck. When the stent is completely deployed, an endovascular patch is formed and anchored around the neck of the BBA. The procedure was successful in all cases. No acute complications developed in any case. No rerupture or recurrence of the BBA occurred during follow-up. One patient with Hunt-Hess V subarachnoid hemorrhage died of multiple organ failure 4 months post treatment. Another patient died of intracranial infection related to the ventricle-peritoneal shunt. The remaining 6 patients had good clinical outcomes (modified Rankin Scale score of zero). Endovascular patch embolization is an improvement on stent-assisted coil embolization, which could be successfully performed only with extensive skill and patience. Endovascular patch embolization could be an effective method in BBA treatment. However, its efficacy and safety should be verified in a larger patient cohort and long-term follow-up study. Copyright © 2018. Published by

  2. Tuberothalamic Artery Infarction Following Coil Embolization of a Ruptured Posterior Communicating Artery Aneurysm Belonging to a Transitional Type Posterior Cerebral Artery

    PubMed Central

    Lee, Kyeong Duk; Kwon, Soon Chan; Muniandy, Sarawana; Park, Eun Suk; Sim, Hong Bo; Lyo, In Uk

    2013-01-01

    Summary There are many potential anatomical variations in the connection between the internal carotid artery and the posterior circulation through the posterior communicating artery (PCoA). We describe the endovascular treatment of an aneurysm arising near the origin of the PCoA belonging to a transitional type posterior cerebral artery. Coil embolization subsequently resulted in thrombo-occlusion of the adjacent PCoA causing thalamic infarction even though sufficient retrograde flow had been confirmed pre-operatively by Allcock’s test. PMID:24070079

  3. Analysis of risk factors for perifocal oedema after endovascular embolization of unruptured intracranial arterial aneurysms

    PubMed Central

    Lukic, Snezana; Jankovic, Slobodan; Popovic, Katarina Surlan; Bankovic, Dragic; Popovic, Peter; Mijailovic, Milan

    2015-01-01

    Background Endovascular embolization is a treatment of choice for the management of unruptured intracranial aneurysms, but sometimes is complicated with perianeurysmal oedema. The aim of our study was to establish incidence and outcomes of perianeurysmal oedema after endovascular coiling of unruptured intracranial aneurysms, and to reveal possible risk factors for development of this potentially serious complication. Methods In total 119 adult patients with endovascular embolization of unruptured intracranial aneurysm (performed at Department for Interventional Neuroradiology, Clinical Center, Kragujevac, Serbia) were included in our study. The embolizations were made by electrolite-detachable platinum coils: pure platinum, hydrophilic and combination of platinum and hydrophilic coils. Primary outcome variable was perianeurysmal oedema visualized by magnetic resonance imaging (MRI) 7, 30 and 90 days after the embolization. Results The perianurysmal oedema appeared in 47.6% of patients treated with hydrophilic coils, in 21.6% of patients treated with platinum coils, and in 53.8% of those treated with mixed type of the coils. The multivariate logistic regression showed that variables associated with occurrence of perianeurysmal oedema are volume of the aneurysm, hypertension, diabetes and smoking habit. Hypertension is the most important independent predictor of the perianeurysmal oedema, followed by smoking and diabetes. Conclusions The results of our study suggest that older patients with larger unruptured intracranial aneurysms, who suffer from diabetes mellitus and hypertension, and have the smoking habit, are under much higher risk of having perianeurysmal oedema after endovascular coiling. PMID:26834520

  4. Balloon-assisted enteroscopy for suspected Meckel’s diverticulum and indefinite diagnostic imaging workup

    PubMed Central

    Gomes, Guilherme Francisco; Bonin, Eduardo Aimore; Noda, Rafael William; Cavazzola, Leandro Totti; Bartholomei, Thiago Ferreira

    2016-01-01

    Meckel’s diverticulum (MD) is estimated to affect 1%-2% of the general population, and it represents a clinically silent finding of a congenital anomaly in up to 85% of the cases. In adults, MD may cause symptoms, such as overt occult lower gastrointestinal bleeding. The diagnostic imaging workup includes computed tomography scan, magnetic resonance imaging enterography, technetium 99m scintigraphy (99mTc) using either labeled red blood cells or pertechnetate (known as the Meckel’s scan) and angiography. The preoperative detection rate of MD in adults is low, and many patients ultimately undergo exploratory laparoscopy. More recently, however, endoscopic identification of MD has been possible with the use of balloon-assisted enteroscopy via direct luminal access, which also provides visualization of the diverticular ostium. The aim of this study was to review the diagnosis by double-balloon enteroscopy of 4 adults with symptomatic MD but who had negative diagnostic imaging workups. These cases indicate that balloon-assisted enteroscopy is a valuable diagnostic method and should be considered in adult patients who have suspected MD and indefinite findings on diagnostic imaging workup, including negative Meckel’s scan. PMID:27803776

  5. Successful treatment of acquired uterine arterial venous malformation using N-butyl-2-cyanoacrylate under balloon occlusion

    PubMed Central

    Ogasawara, Go; Ishida, Kenichiro; Fujii, Kaoru; Yamane, Takuro; Nishimaki, Hiroshi; Matsunaga, Keiji; Inoue, Yusuke

    2014-01-01

    We present two cases of acquired uterine arterial venous malformation (AVM) which was diagnosed because of massive genital bleeding successfully treated with transcatheter arterial embolization (TAE), using N-butyl-2-cyanoacrylate (NBCA) under balloon occlusion. Balloon occlusion at the uterine artery was performed in both patients for diffuse distribution of NBCA in multiple feeding branches, as well as to the pseudoaneurysm, and for the prevention of NBCA reflux. In one of our patients, balloon occlusion of the draining vein was simultaneously performed to prevent NBCA migration through accompanying high-flow arteriovenous fistula (AVF). Doppler ultrasound at 6 months of both patients documented persistent complete occlusion of AVM. Complete and safe obliteration of acquired uterine AVM was accomplished using NBCA as embolic agent, under balloon occlusion at the communicating vessels of acquired uterine AVM. PMID:25346850

  6. Retrievable Stent-Assisted Coiling Technique Using a Solitaire Stent: Treatment of Pancreaticoduodenal Artery Aneurysm Associated With Celiac Artery Occlusion.

    PubMed

    Sanal, Bekir; Nas, Omer Fatih; Hacikurt, Kadir; Hakyemez, Bahattin; Erdogan, Cuneyt

    2016-02-01

    True aneurysm of pancreaticoduodenal arcade (PDA) is usually accompanied by stenosis or occlusion of celiac trunk (CeT). The up-to-date and first choice treatment modality of PDA aneurysm is the endovascular approach in nearly all cases except few selected ones necessitating surgery. The main approach in endovascular treatment is embolization of the aneurysm by preserving the parent artery. A case with concomitant CeT occlusion and PDA aneurysm was treated with coil embolization by preserving inferior pancreaticoduodenal artery with retrievable Solitaire(®) stent. In our knowledge, this is the first case with PDA aneurysm treated with this technique. © The Author(s) 2016.

  7. [Life-threatening hemoptysis. Treatment with transcatheter embolization].

    PubMed

    Gimeno Peribáñez, M J; Madariaga, B; Alfonso Aguirán, E R; Medrano Peña, J; Fernández Gómez, J A; Herrera, M; de Gregorio Ariza, M A

    1999-09-01

    To evaluate the immediate and long-term efficacy of transcatheter embolization of bronchial, systemic and pulmonary arteries to treat life-threatening hemoptysis. Likewise, we propose the systematic treatment of life-threatening hemoptysis by means of transcatheter embolization. One hundred seven angiographies were performed on the same number of patients experiencing life-threatening hemoptysis with bleeding exceeding 150 ml in 24 hours. Before angiography, we rinsed the vessels with cold saline solution and adrenalin through the catheter. Thirty-three patients were female and 74 were male. Mean age was 52.3 years (range 12 to 75 years). Embolization was performed in 104 (3 in patients with recurrent hemoptysis) using polyvinyl alcohol and micro-coils. Bronchial and systemic arteries of the affected hemithorax (mammary and lateral thoracic arteries) were checked in all patients. If findings were negative or bleeding was recurrent, we also performed pulmonary arteriography. In two cases we were unable to catheterize the artery theoretically responsible for bleeding. Examination of both arterial and systemic vessels proved normal in one patient. The embolization technique was successful in 99% (103/104) of the cases and the rate of immediate clinical success was 95.1% (99/104). The mean time of follow-up was 43.2 months (range 3 to 66 months). Hemoptysis recurred in 15.3% (16 cases) within a mean 8.3 months (range 15 days to 48 months); embolization was repeated in 14 of these patients with satisfactory results, while two underwent surgery. In five patients (4.8%) we observed complications requiring no additional medical treatment: one instance of coil migration to the deep femoral artery, from which the coil was removed in a basket; two cases of bronchial artery extravasation with small mediastinal hematomas; and two hematomas at the points of puncture. Selective or supra-selective embolization of the arteries that feed the bronchi provides effective management of

  8. Post-traumatic hepatic artery pseudo-aneurysm combined with subphrenic liver abscess treated with embolization.

    PubMed

    Sun, Long; Guan, Yong-Song; Wu, Hua; Pan, Wei-Min; Li, Xiao; He, Qing; Liu, Yuan

    2006-05-07

    A 23-year-old man with post-traumatic hepatic artery pseudo-aneurysm and subphrenic liver abscess was admitted. He underwent coil embolization of hepatic artery pseudo-aneurysm. The pseudo-aneurysm was successfully obstructed and subphrenic liver abscess was controlled. Super-selective trans-catheter coil embolization may represent an effective treatment for hepatic artery pseudo-aneurysm combined with subphrenic liver abscess in the absence of other therapeutic alternatives.

  9. Use of the Ascent balloon for a 2-in-1 remodeling technique: feasibility and initial experience: case report.

    PubMed

    Clarençon, Frédéric; Pérot, Guillaume; Biondi, Alessandra; Di Maria, Federico; Szatmary, Zoltan; Chiras, Jacques; Sourour, Nader

    2012-03-01

    To present the feasibility of using the Ascent balloon, a new double-lumen remodeling balloon, for a new 2-in-1 technique allowing coiling through the lumen of the balloon without the use of an additional coiling microcatheter. Remodeling technique had enlarged the indications for endovascular treatment of intracranial aneurysm. Nevertheless, one of the limitations of this technique is that it requires using 2 devices in the same parent artery. A 55-year-old woman presented with a 7.7 × 4.5-mm incidental anterior communicating artery aneurysm. Only 1 A1 segment (left side) was patent on the cerebral angiogram. A 6F Fargo Max guiding catheter was positioned in the left petrous internal carotid artery. The Ascent balloon was placed in front of the neck of the aneurysm after navigation on a Traxcess 0.014-in guidewire. Coiling of the aneurysm sac was performed via 1 lumen of the device under iterative inflations of the balloon through the second lumen. This new 2-in-1 technique using a sole remodeling balloon without an additional coiling microcatheter is very promising, especially in cases of a small-caliber parent artery.

  10. Clinical efficacy and safety of transcatheter embolization for vascular complications after percutaneous nephrolithotomy

    PubMed Central

    Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet

    2017-01-01

    Introduction Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. Aim To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. Material and methods We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Results Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19–75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3–18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Conclusions Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization. PMID:29362656

  11. Onyx versus nBCA and coils in the treatment of intracranial dural arteriovenous fistulas

    PubMed Central

    Choo, Douglas M

    2016-01-01

    Background and purpose Intracranial dural arteriovenous fistulas (DAVFs) with cortical venous drainage have significant morbidity and mortality. Complete closure of these lesions is necessary to reduce these risks. The purpose of our study was to compare the outcome of DAVFs treated with Onyx versus those treated with n-Butyl Cyanoacrylate (nBCA) and coil embolization in a case-control study. Compared with nBCA and coil embolization, we hypothesized that Onyx embolization for DAVF is safer and has a higher chance of complete obliteration, with no need for post-embolization surgery for the DAVF. Materials and methods From 1998 to 2015, 29 patients who had DAVFs were treated with endovascular embolization. Of these, 24 patients had imaging available for analysis. Successful closure rates, complications, and procedure time were compared between the embolization techniques. Results The chance of not requiring post-embolization surgery with Onyx (81.8%) was significantly higher (p = 0.005) than with nBCA (22.22%). The complication rate with Onyx (9.1%) tended to be lower compared with that of nBCA (22.22%; p = 0.37). Procedural time was not significantly different between Onyx (mean 267 minutes) and nBCA (mean 288 minutes) (p = 0.59). The odds ratio of a DAVF being treated with Onyx and then requiring no follow-up surgery was 17.5 (95% CI 1.97–155.4). Conclusion Our case-control study suggests that Onyx embolization is superior to nBCA and coil embolization in completely obliterating DAVFs, with higher odds of no post-embolization surgery. We also found that Onyx is safe for embolization of DAVFs, with no associated neurological mortality and morbidity. PMID:26748082

  12. Onyx versus nBCA and coils in the treatment of intracranial dural arteriovenous fistulas.

    PubMed

    Choo, Douglas M; Shankar, Jai Jai Shiva

    2016-04-01

    Intracranial dural arteriovenous fistulas (DAVFs) with cortical venous drainage have significant morbidity and mortality. Complete closure of these lesions is necessary to reduce these risks. The purpose of our study was to compare the outcome of DAVFs treated with Onyx versus those treated with n-Butyl Cyanoacrylate (nBCA) and coil embolization in a case-control study. Compared with nBCA and coil embolization, we hypothesized that Onyx embolization for DAVF is safer and has a higher chance of complete obliteration, with no need for post-embolization surgery for the DAVF. From 1998 to 2015, 29 patients who had DAVFs were treated with endovascular embolization. Of these, 24 patients had imaging available for analysis. Successful closure rates, complications, and procedure time were compared between the embolization techniques. The chance of not requiring post-embolization surgery with Onyx (81.8%) was significantly higher (p = 0.005) than with nBCA (22.22%). The complication rate with Onyx (9.1%) tended to be lower compared with that of nBCA (22.22%; p = 0.37). Procedural time was not significantly different between Onyx (mean 267 minutes) and nBCA (mean 288 minutes) (p = 0.59). The odds ratio of a DAVF being treated with Onyx and then requiring no follow-up surgery was 17.5 (95% CI 1.97-155.4). Our case-control study suggests that Onyx embolization is superior to nBCA and coil embolization in completely obliterating DAVFs, with higher odds of no post-embolization surgery. We also found that Onyx is safe for embolization of DAVFs, with no associated neurological mortality and morbidity. © The Author(s) 2016.

  13. Post-traumatic hepatic artery pseudo-aneurysm combined with subphrenic liver abscess treated with embolization

    PubMed Central

    Sun, Long; Guan, Yong-Song; Wu, Hua; Pan, Wei-Min; Li, Xiao; He, Qing; Liu, Yuan

    2006-01-01

    A 23-year-old man with post-traumatic hepatic artery pseudo-aneurysm and subphrenic liver abscess was admitted. He underwent coil embolization of hepatic artery pseudo-aneurysm. The pseudo-aneurysm was successfully obstructed and subphrenic liver abscess was controlled. Super-selective trans-catheter coil embolization may represent an effective treatment for hepatic artery pseudo-aneurysm combined with subphrenic liver abscess in the absence of other therapeutic alternatives. PMID:16718774

  14. Optimizing logistics for balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices by doing away with the indwelling balloon: concept and techniques.

    PubMed

    Saad, Wael E; Nicholson, David B

    2013-06-01

    Since the conception of balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices 25 years ago, the placement of an indwelling balloon for hours has been central to the BRTO procedure. Numerous variables and variations of the BRTO procedure have been described, including methods to reduce sclerosant, combining percutaneous transhepatic obliteration, varying sclerosant, and using multiple sclerosants within the same procedure. However, the consistent feature of BRTO has always remained the indwelling balloon. Placing an indwelling balloon over hours for the BRTO procedure is a logistical burden that taxes the interventional radiology team and hospital resources. Substituting the balloon with hardware (coils or Amplatzer vascular plugs [AVPs] or both) is technically feasible and its risks most likely correlate with gastrorenal shunt (GRS) size. The current authors use packed 0.018- or 0.035-in coils or both for small gastric variceal systems (GRS size A and B) and AVPs for GRS sizes up to size E (from size A-E). The current authors recommend an indwelling balloon (no hardware substitute) for very large gastric variceal system (GRS size F). Substituting the indwelling balloon for hardware in size F and potentially size E GRS can also be risky. The current article describes the techniques of placing up to 16-mm AVPs through balloon occlusion guide catheters and then deflating the balloon once it has been substituted with the AVPs. In addition, 22-mm AVPs can be placed through sheaths once the balloon occlusion catheters are removed to further augment the 16-mm Amplatzer occlusion. To date, there are no studies describing, let alone evaluating, the clinical feasibility of performing BRTO without indwelling balloons. The described techniques have been successfully performed by the current authors. However, the long-term safety and effectiveness of these techniques is yet to be determined. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Stent-Assisted Endovascular Treatment of Anterior Communicating Artery Aneurysms - Literature Review.

    PubMed

    Kocur, Damian; Ślusarczyk, Wojciech; Przybyłko, Nikodem; Bażowski, Piotr; Właszczuk, Adam; Kwiek, Stanisław

    2016-01-01

    The anterior cerebral artery is a common location of intracranial aneurysms. The standard coil embolization technique is limited by its inability to occlude wide-neck aneurysms. Stent deployment across the aneurysm neck supports the coil mass inside the aneurysmal sac, and furthermore, has an effect on local hemodynamic and biologic changes. In this article, various management strategies and techniques as well as angiographic outcomes and complications related to stent-assisted endovascular treatment of anterior communicating artery aneurysms are presented. This treatment method is safe and associated with low morbidity and mortality rates.

  16. [Embolization as a treatment method in post-traumatic right hepatic artery pseudoaneurysm].

    PubMed

    Dobrowolska-Bak, Malgorzata; Brzegowy, Paweł; Urbanik, Andrzej

    2012-01-01

    A case of 42-year-old man with post-traumatic right hepatic artery pseudoaneurysm successfully treated by endovascular embolization with histoacrylate glue is presented. Despite coils are mostly used embolic material in pseudoaneurysm, embolization with histoacrylate glue can be highly effective and quick treatment modality for post-traumatic hepatic artery pseudoaneurysm, especially in cases when it is impossible to use standard materials.

  17. Robot-assisted ligation of bronchial artery could be an alternative to embolization.

    PubMed

    Pochulu, Bruno; Sarsam, Omar; Peillon, Christophe; Baste, Jean-Marc

    2018-03-01

    A 37-year-old patient presented with a self-limiting episode of moderate haemoptysis. Contrast-enhanced chest computed tomography showed a tortuous and dilated right bronchial artery arising from the descending aorta at the level of T6. Therapeutic angiography was attempted, but in the presence of spinal artery arising from the bronchial artery in question, selective embolization was contraindicated due to risk of spinal cord ischaemia. After a multidisciplinary meeting, it was decided to attempt surgery to ligate this pathological artery. We performed minimally invasive robot-assisted ligation of this pathological artery. The postoperative course was uneventful with good clinical and radiological outcome at 3-month follow-up. A minimally invasive approach provides a real alternative to embolization and could be a therapeutic option.

  18. PROTECT: PRoximal balloon Occlusion TogEther with direCt Thrombus aspiration during stent retriever thrombectomy - evaluation of a double embolic protection approach in endovascular stroke treatment.

    PubMed

    Maegerlein, Christian; Mönch, Sebastian; Boeckh-Behrens, Tobias; Lehm, Manuel; Hedderich, Dennis M; Berndt, Maria Teresa; Wunderlich, Silke; Zimmer, Claus; Kaesmacher, Johannes; Friedrich, Benjamin

    2017-12-08

    Stent retriever-based mechanical thrombectomy (MT) for emergent large vessel occlusions (ELVO) is often complicated by thrombus fragmentation causing distal embolization and embolization to new vascular territories. Well-established embolic protection approaches include proximal flow arrest and distal aspiration techniques during stent retriever maneuvers. Aiming at the reduction of thrombus fragmentation during MT we evaluated a technical approach combining proximal balloon occlusion together with direct thrombus aspiration during MT: the PROTECT technique. We performed a case-control study comparing the PROTECT technique with sole distal aspiration during MT regarding technical and procedural parameters, n=200 patients with ELVO of either the terminus of the internal carotid artery or the proximal middle artery were included. PROTECT resulted in a shorter procedure time (29 vs 40 min; P=0.002), in a higher rate of successful recanalizations (100% vs 78%; P=0.001) and a higher rate of complete reperfusions (70% vs 39%; P<0.001) compared with sole distal aspiration during MT. The PROTECT technique is a promising new approach to significantly reduce thrombus fragmentation and, hence distal embolization during MT. This safe and efficient technique needs to be validated in larger trials to confirm our results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Pipeline embolization device versus coiling for the treatment of large and giant unruptured intracranial aneurysms: a cost-effectiveness analysis.

    PubMed

    Wali, Arvin R; Park, Charlie C; Santiago-Dieppa, David R; Vaida, Florin; Murphy, James D; Khalessi, Alexander A

    2017-06-01

    OBJECTIVE Rupture of large or giant intracranial aneurysms leads to significant morbidity, mortality, and health care costs. Both coiling and the Pipeline embolization device (PED) have been shown to be safe and clinically effective for the treatment of unruptured large and giant intracranial aneurysms; however, the relative cost-to-outcome ratio is unknown. The authors present the first cost-effectiveness analysis to compare the economic impact of the PED compared with coiling or no treatment for the endovascular management of large or giant intracranial aneurysms. METHODS A Markov model was constructed to simulate a 60-year-old woman with a large or giant intracranial aneurysm considering a PED, endovascular coiling, or no treatment in terms of neurological outcome, angiographic outcome, retreatment rates, procedural and rehabilitation costs, and rupture rates. Transition probabilities were derived from prior literature reporting outcomes and costs of PED, coiling, and no treatment for the management of aneurysms. Cost-effectiveness was defined, with the incremental cost-effectiveness ratios (ICERs) defined as difference in costs divided by the difference in quality-adjusted life years (QALYs). The ICERs < $50,000/QALY gained were considered cost-effective. To study parameter uncertainty, 1-way, 2-way, and probabilistic sensitivity analyses were performed. RESULTS The base-case model demonstrated lifetime QALYs of 12.72 for patients in the PED cohort, 12.89 for the endovascular coiling cohort, and 9.7 for patients in the no-treatment cohort. Lifetime rehabilitation and treatment costs were $59,837.52 for PED; $79,025.42 for endovascular coiling; and $193,531.29 in the no-treatment cohort. Patients who did not undergo elective treatment were subject to increased rates of aneurysm rupture and high treatment and rehabilitation costs. One-way sensitivity analysis demonstrated that the model was most sensitive to assumptions about the costs and mortality risks for PED

  20. Monorail snare technique for the recovery of stretched platinum coils: technical case report.

    PubMed

    Fiorella, David; Albuquerque, Felipe C; Deshmukh, Vivek R; McDougall, Cameron G

    2005-07-01

    Coil stretching represents a potentially hazardous technical complication not infrequently encountered during the embolization of cerebral aneurysms. Often, the stretched coil cannot be advanced into the aneurysm or withdrawn intact. The operator is then forced to attempt to retract the damaged coil, which may result in coil breakage, leaving behind a significant length of potentially thrombogenic stretched coil material within the parent vessel. To overcome this problem, we devised a technique to snare the distal, unstretched, intact portion of the platinum coil by use of the indwelling microcatheter and stretched portion of the coil as a monorail guide. We have used this technique successfully in four patients to snare coils stretched during cerebral aneurysm embolization. Three of these patients were undergoing Neuroform (Boston Scientific/Target, Fremont, CA) stent-supported coil embolization of unruptured aneurysms. In all cases, the snare was advanced easily to the targeted site for coil engagement by use of the microcatheter as a monorail guide. Once the intact distal segment of the coil was ensnared, coil removal was uneventful, with no disturbance of the remainder of the indwelling coil pack or Neuroform stent. A 2-mm Amplatz Goose Neck microsnare (Microvena Corp., White Bear Lake, MN) was placed through a Prowler-14 microcatheter (Cordis Corp., Miami, FL). The hub of the indwelling SL-10 microcatheter (Boston Scientific, Natick, MA) was then cut away with a scalpel, leaving the coil pusher wire intact, and removed. The open 2-mm snare was then advanced over the outside of the coil pusher wire and microcatheter. The snare and Prowler-14 microcatheter were then advanced into the guiding catheter (6- or 7-French) as a unit over the indwelling SL-10 microcatheter. By use of the SL-10 microcatheter and coil as a "monorail" guide, the snare was advanced over and beyond the microcatheter and the stretched portion of the coil until the snare was in position to

  1. Stent-Assisted Endovascular Treatment of Anterior Communicating Artery Aneurysms – Literature Review

    PubMed Central

    Kocur, Damian; Ślusarczyk, Wojciech; Przybyłko, Nikodem; Bażowski, Piotr; Właszczuk, Adam; Kwiek, Stanisław

    2016-01-01

    Summary The anterior cerebral artery is a common location of intracranial aneurysms. The standard coil embolization technique is limited by its inability to occlude wide-neck aneurysms. Stent deployment across the aneurysm neck supports the coil mass inside the aneurysmal sac, and furthermore, has an effect on local hemodynamic and biologic changes. In this article, various management strategies and techniques as well as angiographic outcomes and complications related to stent-assisted endovascular treatment of anterior communicating artery aneurysms are presented. This treatment method is safe and associated with low morbidity and mortality rates. PMID:27559426

  2. Direct traumatic carotid cavernous fistula: angiographic classification and treatment strategies. Study of 172 cases.

    PubMed

    Chi, Cuong Tran; Nguyen, Dang; Duc, Vo Tan; Chau, Huynh Hong; Son, Vo Tan

    2014-01-01

    We report our experience in treatment of traumatic direct carotid cavernous fistula (CCF) via endovascular intervention. We hereof recommend an additional classification system for type A CCF and suggest respective treatment strategies. Only type A CCF patients (Barrow's classification) would be recruited for the study. Based on the angiographic characteristics of the CCF, we classified type A CCF into three subtypes including small size, medium size and large size fistula depending on whether there was presence of the anterior carotid artery (ACA) and/or middle carotid artery (MCA). Angiograms with opacification of both ACA and MCA were categorized as small size fistula. Angiograms with opacification of either ACA or MCA were categorized as medium size fistula and those without opacification of neither ACA nor MCA were classified as large size fiatula. After the confirm angiogram, endovascular embolization would be performed impromptu using detachable balloon, coils or both. All cases were followed up for complication and effect after the embolization. A total of 172 direct traumatic CCF patients were enrolled. The small size fistula was accountant for 12.8% (22 cases), medium size 35.5% (61 cases) and large size fistula accountant for 51.7% (89 cases). The successful rate of fistula occlusion under endovascular embolization was 94% with preservation of the carotid artery in 70%. For the treatment of each subtype, a total of 21/22 cases of the small size fistulas were successfully treated using coils alone. The other single case of small fistula was defaulted. Most of the medium and large size fistulas were cured using detachable balloons. When the fistula sealing could not be obtained using detachable balloon, coils were added to affirm the embolization of the cavernous sinus via venous access. There were about 2.9% of patient experienced direct carotid artery puncture and 0.6% puncture after carotid artery cut-down exposure. About 30% of cases experienced

  3. Mechanisms of Healing in Coiled Intracranial Aneurysms: A Review of the Literature

    PubMed Central

    Brinjikji, Waleed; Kallmes, David F; Kadirvel, Ramanathan

    2016-01-01

    Summary Recanalization of intracranial aneurysms following endovascular coiling remains a frustratingly common occurrence. An understanding of the molecular and histopathological mechanisms of aneurysm healing following coil embolization is essential to improving aneurysm occlusion rates. Histolopathologic studies in coiled human and experimental aneurysms suggest that during the first month post-coiling, thrombus formation and active inflammation occur within the aneurysm dome. Several months following embolization, the aneurysm is excluded from the parent vessel by formation of a neointimal layer, which is often thin and discontinuous, across the aneurysm neck. Numerous coil modifications and systemic therapies have been tested in animals and humans in an attempt to improve the aneurysm healing process; these modifications have met with variable levels of success. In this review, we summarize the histopathologic and molecular biology of aneurysm healing and discuss how these findings have been applied in an attempt to improve angiographic outcomes in patients harboring intracranial aneurysm. PMID:25430855

  4. Tuberothalamic artery infarction following coil embolization of a ruptured posterior communicating artery aneurysm belonging to a transitional type posterior cerebral artery. A case report.

    PubMed

    Lee, Kyeong Duk; Kwon, Soon Chan; Muniandy, Sarawana; Park, Eun Suk; Sim, Hong Bo; Lyo, In Uk

    2013-09-01

    There are many potential anatomical variations in the connection between the internal carotid artery and the posterior circulation through the posterior communicating artery (PCoA). We describe the endovascular treatment of an aneurysm arising near the origin of the PCoA belonging to a transitional type posterior cerebral artery. Coil embolization subsequently resulted in thrombo-occlusion of the adjacent PCoA causing thalamic infarction even though sufficient retrograde flow had been confirmed pre-operatively by Allcock's test.

  5. Successful Coil Embolization of a Ruptured Basilar Artery Aneurysm in a Child with Leukemia: A Case Report

    PubMed Central

    HAYASHI, Shihori; MAEHARA, Taketoshi; MUKAWA, Maki; AOYAGI, Masaru; YOSHINO, Yoshikazu; NEMOTO, Shigeru; ONO, Toshiaki; OHNO, Kikuo

    2014-01-01

    Ruptured intracranial aneurysms are rare in the pediatric population compared to adults. This has incited considerable discussion on how to treat children with this condition. Here, we report a child with a ruptured saccular basilar artery aneurysm that was successfully treated with coil embolization. A 12-year-old boy with acute lymphoblastic leukemia and accompanying abdominal candidiasis after chemotherapy suddenly complained of a severe headache and suffered consciousness disturbance moments later. Computed tomography scans and cerebral angiography demonstrated acute hydrocephalus and subarachnoid hemorrhage caused by saccular basilar artery aneurysm rupture. External ventricular drainage was performed immediately. Because the patient was in severe condition and did not show remarkable signs of central nervous system infection in cerebrospinal fluid studies, we applied endovascular treatment for the ruptured saccular basilar artery aneurysm, which was successfully occluded with coils. The patient recovered without new neurological deficits after ventriculoperitoneal shunting. Recent reports indicate that both endovascular and microsurgical techniques can be used to effectively treat ruptured cerebral aneurysms in pediatric patients. A minimally invasive endovascular treatment was effective in the present case, but long-term follow-up will be necessary to confirm the efficiency of endovascular treatment for children with ruptured saccular basilar artery aneurysms. PMID:24257487

  6. Successful coil embolization of a ruptured basilar artery aneurysm in a child with leukemia: a case report.

    PubMed

    Hayashi, Shihori; Maehara, Taketoshi; Mukawa, Maki; Aoyagi, Masaru; Yoshino, Yoshikazu; Nemoto, Shigeru; Ono, Toshiaki; Ohno, Kikuo

    2014-01-01

    Ruptured intracranial aneurysms are rare in the pediatric population compared to adults. This has incited considerable discussion on how to treat children with this condition. Here, we report a child with a ruptured saccular basilar artery aneurysm that was successfully treated with coil embolization. A 12-year-old boy with acute lymphoblastic leukemia and accompanying abdominal candidiasis after chemotherapy suddenly complained of a severe headache and suffered consciousness disturbance moments later. Computed tomography scans and cerebral angiography demonstrated acute hydrocephalus and subarachnoid hemorrhage caused by saccular basilar artery aneurysm rupture. External ventricular drainage was performed immediately. Because the patient was in severe condition and did not show remarkable signs of central nervous system infection in cerebrospinal fluid studies, we applied endovascular treatment for the ruptured saccular basilar artery aneurysm, which was successfully occluded with coils. The patient recovered without new neurological deficits after ventriculoperitoneal shunting. Recent reports indicate that both endovascular and microsurgical techniques can be used to effectively treat ruptured cerebral aneurysms in pediatric patients. A minimally invasive endovascular treatment was effective in the present case, but long-term follow-up will be necessary to confirm the efficiency of endovascular treatment for children with ruptured saccular basilar artery aneurysms.

  7. Endovascular treatment of wide-neck intracranial aneurysms using a microcatheter protective technique: results and outcomes in 75 aneurysms.

    PubMed

    Lee, J Y; Seo, J H; Cho, Y D; Kang, H-S; Han, M H

    2011-05-01

    The microcatheter protective technique positions an additional microcatheter in the parent or side-branching artery to protect it during coil embolization. The purpose of this study was to describe this method and to evaluate its efficacy and safety as an alternative to a multiple-microcatheter or balloon- or stent-assisted technique for wide-neck aneurysms. A retrospective review of 74 patients (43 women; mean age, 59.6 years) with 75 wide-neck aneurysms treated with the microcatheter protective technique between January 2003 and April 2010 was performed. Immediate postembolization angiograms were evaluated by using a conventional angiographic scale, and clinical evaluation was performed by using the GOS. Clinical and imaging follow-up were available in 57 (76%) patients, with a mean of 14.7 months. Postembolization angiograms demonstrated total occlusion in 45 of 75 (60%) aneurysms, a neck remnant in 17 (22.7%), and body filling in 13 (17.3%). The technique-related complication rate was 17.4% (13/75), and the procedural-related morbidity rate was 1.3% (1/74). All patients, except 3 complicated cases with a GOS of <4, had a GOS of 5 at the end of the study period. Of the 57 aneurysms with follow-up, recanalization developed in 5 (8.8%) aneurysms, and 3 (5.3%) cases of major recanalization were re-treated endovascularly. The microcatheter protective technique is feasible and safe for coil embolization of wide-neck aneurysms, especially in cases that are not suitable for multiple catheter or balloon- or stent-assisted techniques.

  8. Superselective Embolization with Coils in High-Flow Priapism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kress, Oliver; Heidenreich, A.; Klose, Klaus Jochen

    2002-08-15

    Priapism can be divided into 'low-flow' veno-occlusive priapism and, especially in children, rare 'high-flow' arterial priapism. We report a 5-year-old boy who developed arterial priapism after blunt perineal trauma that was successfully treated by superselective embolization with microcoils.

  9. Occlusion of M1 segment after superficial temporal artery-middle cerebral artery bypass in a giant M1 aneurysm with Onyx-34 injected via a double-lumen balloon under balloon inflation.

    PubMed

    Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader

    2013-05-31

    A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery.

  10. Occlusion of M1 segment after superficial temporal artery-middle cerebral artery bypass in a giant M1 aneurysm with Onyx-34 injected via a double-lumen balloon under balloon inflation.

    PubMed

    Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader

    2014-05-01

    A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery.

  11. Occlusion of M1 segment after superficial temporal artery-middle cerebral artery bypass in a giant M1 aneurysm with Onyx-34 injected via a double-lumen balloon under balloon inflation

    PubMed Central

    Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader

    2013-01-01

    A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery. PMID:23729720

  12. Complications of retrograde balloon cautery endopyelotomy.

    PubMed

    Schwartz, B F; Stoller, M L

    1999-11-01

    Adult ureteropelvic junction obstruction is increasingly managed with endoscopic techniques. Retrograde balloon cautery endopyelotomy is quick, requires minimal hospital stay and allows most patients a rapid return to work. The complication rate of retrograde balloon cautery endopyelotomy ranges from 13 to 34%, with vascular injury in 0 to 16% of patients. We report 5 uncommon complications, including 4 vascular injuries, that clinicians should be familiar with when using this technique. We reviewed 52 retrograde endoscopic endopyelotomy procedures performed during a 5-year period. There were 5 uncommon complications. Accessory lower pole renal artery injuries occurred in 3 patients, 1 of whom presented 12 days after endopyelotomy. Embolization was successfully performed in all 3 cases and none had subsequent hypertension. In 1 case a right ovarian vein laceration was not evident on preoperative or postoperative angiography. Emergency post-embolization abdominal exploration revealed a 2 mm. injury to the right ovarian vein before entering the right renal vein close to the ureteropelvic junction incision. Nephrectomy and ovarian vein ligature were curative. In 1 case the electrocautery wire broke intracorporeally after firing, resulting in a bobby pin-like configuration. Successful removal was accomplished by twisting the catheter and wrapping the wire around the tip, enabling atraumatic removal. Retrograde balloon cautery endopyelotomy is an emerging technology with potential adverse outcomes. The complications we noted are complex and potentially life threatening. Awareness of these complications may help avoid poor outcomes and expedite appropriate treatment.

  13. Genuine splenic artery aneurysm rupture treated by N‐butyl cyanoacrylate and metallic coils under resuscitative endovascular balloon occlusion of the aorta

    PubMed Central

    Hagiwara, Shuichi; Miyazaki, Masaya; Kaneko, Minoru; Murata, Masato; Nakajima, Jun; Ohyama, Yoshio; Tamura, Jun'ichi; Tsushima, Yoshito; Oshima, Kiyohiro

    2016-01-01

    Case A 66 year‐old woman who presented with sudden lower abdominal pain was transferred to our emergency room. Vital signs were stable on arrival at the hospital, but immediately became unstable. Systolic/diastolic blood pressure and heart rate were 66/33 mmHg and 70 b.p.m., respectively. Computed tomography scanning showed splenic artery aneurysm rupture and extravasation. The patient was treated non‐operatively and definitively by endovascular therapy comprising resuscitative endovascular occlusion of the aorta for hemodynamic control, N‐butyl cyanoacrylate, and metallic coils as an embolization material. Outcome On admission day 3, she was enrolled in another department and admission day 54, she was discharged. Conclusion Although resuscitative endovascular occlusion of the aorta and N‐butyl cyanoacrylate is known to be effective, the use of resuscitative endovascular occlusion of the aorta with transcatheter arterial embolization and N‐butyl cyanoacrylate for non‐traumatic bleeding has not previously been reported. By combining and adapting these devices, their applications in endovascular management may be increased. PMID:29123801

  14. Microcoil embolization during abdominal vascular interventions through microcatheters with a tip of 2 French or less.

    PubMed

    Miyayama, Shiro; Yamashiro, Masashi; Hattori, Yuki; Orito, Nobuaki; Matsui, Ken; Tsuji, Kazunobu; Yoshida, Miki; Matsui, Osamu

    2011-05-01

    The aim of this study was to evaluate the technical aspects of embolization using microcoils through a microcatheter with a tip of 2F or smaller during abdominal vascular interventions. Coil embolization through a microcatheter with a tip of 2F or smaller was attempted in 73 procedures. Two types of microcoil-Liquid Coil (Boston Scientific, Watertown, MA, USA) and Tornado Coil (Cook, Bloomington, IN, USA)-were deployed through four types of thinner microcatheter [2F tip (n = 49) and 1.8F tip (n = 24)]. Coil jams in the microcatheter and coil migration were evaluated. In total, 286 microcoils were placed (mean ± SD, 3.9 ± 4.3 coils per procedure, range 1-32 coils). In 19 procedures (26.9%), Liquid Coils were used alone. In 44 (60.3%), Tornado Coils were used alone. In 10 (13.7%), Liquid Coils and Tornado Coils were combined. There were no coil jams in the microcatheter in this series. One Tornado Coil (0.3%) delivered into the gastroduodenal artery migrated to the right hepatic artery. Liquid Coils and Tornado Coils can be placed through a thinner microcatheter without difficulty. However, there is a risk of coil migration in large vessels or at the proximal site because the catheter tip is not stabilized.

  15. Embolization techniques for high-flow arteriovenous malformations with a dominant outflow vein.

    PubMed

    Conway, Allan M; Qato, Khalil; Drury, Jennifer; Rosen, Robert J

    2015-04-01

    The aim of this study was to assess the management and outcomes of arteriovenous malformations (AVMs) with a dominant outflow vein (DOV) treated with retrograde venous embolization. A retrospective review was performed from November 2010 to May 2014 on all patients with a high-flow AVM and associated DOV who underwent transvenous embolization of the DOV. Indications, techniques, complications, and outcomes were reviewed. Fourteen patients (five male; 36%) underwent transvenous embolization of high-flow AVMs with a DOV. Median age was 41.6 years (15.7-65.8 years). The AVM was located on an extremity in eight patients (57%) and in the pelvis in six patients (43%). The indication for the procedure was pain in 11 patients (79%), swelling in 3 patients (21%), a nonhealing wound in 1 patient (7%), and impotence in 1 patient (7%). The median number of prior procedures to treat the AVM was 2.5 (0-13). Transvenous embolization with coils was performed in 13 patients (93%). The Amplatzer vascular plug and Amplatzer septal occluder (St. Jude Medical, St. Paul, Minn) were used in four patients (29%). Concurrent percutaneous puncture embolization of the AVM nidus was used in seven patients (50%) and transcatheter arterial embolization in eight patients (57%). Technical angiographic success was seen in all patients. Five patients (36%) experienced a complete response to treatment, whereas eight (57%) experienced a partial response. Seven patients (50%) required further procedures for residual symptoms. AVMs with a DOV can be successfully treated by a transvenous approach. Percutaneous puncture embolization of the nidus or draining vein and transcatheter arterial embolization may assist in reducing flow. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  16. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    PubMed

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  17. Post-traumatic hepatic artery pseudoaneurysm treated with endovascular embolization and thrombin injection.

    PubMed

    Francisco, Lloret Estañ; Asunción, López Conesa; Antonio, Capel Alemán; Ricardo, Robles Campos; Manuel, Reus Pintado; Caridad, Marín Hernández

    2010-02-27

    Post-traumatic hepatic artery pseudoaneurysm is uncommon, appearing in approximately 1% of hepatic trauma cases. Most are extrahepatic (80%) and have a late onset. Although they are usually asymptomatic, they should always be treated becasue of the high risk of complications, especially breakage. Currently the treatment of choice is endovascular embolization with coils or the exclusion of the pseudoaneurysm using other intravascular devices. Recently there have been accounts of a treatment that combines embolization with coils and image-guided percutaneous human thrombin injection. We present a case of post-traumatic hepatic artery pseudoaneurysm that was successfully treated using this combined technique.

  18. Post-traumatic hepatic artery pseudoaneurysm treated with endovascular embolization and thrombin injection

    PubMed Central

    Francisco, Lloret Estañ; Asunción, López Conesa; Antonio, Capel Alemán; Ricardo, Robles Campos; Manuel, Reus Pintado; Caridad, Marín Hernández

    2010-01-01

    Post-traumatic hepatic artery pseudoaneurysm is uncommon, appearing in approximately 1% of hepatic trauma cases. Most are extrahepatic (80%) and have a late onset. Although they are usually asymptomatic, they should always be treated becasue of the high risk of complications, especially breakage. Currently the treatment of choice is endovascular embolization with coils or the exclusion of the pseudoaneurysm using other intravascular devices. Recently there have been accounts of a treatment that combines embolization with coils and image-guided percutaneous human thrombin injection. We present a case of post-traumatic hepatic artery pseudoaneurysm that was successfully treated using this combined technique. PMID:21160978

  19. Direct Surgery of Previously Coiled Large Internal Carotid Ophthalmic Aneurysm for the Purpose of Optic Nerve Decompression

    PubMed Central

    Kawabata, Shuhei; Toyota, Shingo; Kumagai, Tetsuya; Goto, Tetsu; Mori, Kanji; Taki, Takuyu

    2017-01-01

    Background Progressive visual loss after coil embolization of a large internal carotid ophthalmic aneurysm has been widely reported. It is generally accepted that the primary strategy for this complication should be conservative, including steroid therapy; however, it is not well known as to what approach to take when the conservative therapy is not effective. Case Presentation We report a case of a 55-year-old female presenting with progressive visual loss after the coiling of a ruptured large internal carotid ophthalmic aneurysm. As the conservative therapy had not been effective, we performed neck clipping of the aneurysm with optic canal unroofing, anterior clinoidectomy, and partial removal of the embolized coils for the purpose of optic nerve decompression. After the surgery, the visual symptom was improved markedly. Conclusions It is suggested that direct surgery for the purpose of optic nerve decompression may be one of the options when conservative therapy is not effective for progressive visual disturbance after coil embolization. PMID:28229036

  20. Preoperative fiducial coil placement facilitates robot-assisted laparoscopic excision of retroperitoneal small solitary metastasis of kidney cancer.

    PubMed

    Agrawal, Vineet; Sharma, Ashwani; Wu, Guan

    2014-11-01

    Image-guided fiducial markers are being used in surgery, especially in spine and breast surgery, and radiotherapy, allowing localization of tumor sites precisely. We report a case of fiducial coil use in a man undergoing a robot-assisted laparoscopic resection of a metastatic nodule under the ipsilateral diaphragm after robot-assisted partial nephrectomy performed 2 years ago for a left upper pole renal tumor. The fiducial coil facilitated the localization of the lesion, which would otherwise have been challenging because of its small size and location. In addition, the fiducial coil was helpful to avoid cutting into the lesion directly. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. CE-MRA for follow-up of aneurysms post stent-assisted coiling.

    PubMed

    Agid, R; Schaaf, M; Farb, Ri

    2012-09-01

    This study compared the accuracy of contrast-enhanced MR angiography (CE-MRA) to intra-arterial cerebral angiography (IA-DSA) for assessment of intracranial aneurysms after stent-assisted coiling and to check if the presence of a stent in the parent artery diminishes the accuracy of CE-MRA. Consecutive patients with cerebral aneurysms treated by stent-assisted coiling were evaluated retrospectively. Matching follow-up CE-MRA and IA-DSA were evaluated separately. Evaluation included the presence of aneurysmal remnant, patency and stenosis of parent artery. Twenty-seven patients with 28 aneurysms and 33 matched CE-MRA and IA-DSA studies were evaluated. Nineteen aneurysmal remnants were seen on CE-MRA and 16 on IA-DSA. CE-MRA diagnosed three aneurysmal remnants not appreciated on IA-DSA. Five other remnants were larger on CE-MRA than IA-DSA. None of the remnants were missed on CE-MRA. Parent arteries were patent on both modalities. CE-MRA showed false stenosis of the stented artery in six cases and exaggerated stenosis in two. In 18 cases, CE-MRA showed a short focal "pseudo-stenosis" where the stent's marker bands were located. This was noted whenever the stent's marker bands were located in an artery with luminal diameter ≤2 mm and was called "marker band effect". CE-MRA is an accurate technique for follow-up of aneurysms post stent-assisted coiling with excellent depiction of remnants in spite of the presence of a stent. Apparent stenosis of the stented parent artery on CE-MRA is often false or exaggerated. "Marker band effect" should be recognized as an artifact that appears when stent's marker bands are in a small artery.

  2. Use of flow-diverting stents as salvage treatment following failed stent-assisted embolization of intracranial aneurysms.

    PubMed

    Heiferman, Daniel M; Billingsley, Joshua T; Kasliwal, Manish K; Johnson, Andrew K; Keigher, Kiffon M; Frudit, Michel E; Moftakhar, Roham; Lopes, Demetrius K

    2016-07-01

    Flow-diverting stents, including the Pipeline embolization device (PED) and Silk, have been beneficial in the treatment of aneurysms previously unable to be approached via endovascular techniques. Recurrent aneurysms for which stent-assisted embolization has failed are a therapeutic challenge, given the existing intraluminal construct with continued blood flow into the aneurysm. We report our experience using flow-diverting stents in the repair of 25 aneurysms for which stent-assisted embolization had failed. Nineteen (76%) of these aneurysms at the 12-month follow-up showed improved Raymond class occlusion, with 38% being completely occluded, and all aneurysms demonstrated decreased filling. One patient developed a moderate permanent neurologic deficit. Appropriate stent sizing, proximal and distal construct coverage, and preventing flow diverter deployment between the previously deployed stent struts are important considerations to ensure wall apposition and prevention of endoleak. Flow diverters are shown to be a reasonable option for treating previously stented recurrent cerebral aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Subdural and intracerebral hemorrhage caused by spontaneous bleeding in the middle meningeal artery after coil embolization of a cerebral aneurysm.

    PubMed

    Kohyama, Shinya; Kakehi, Yoshiaki; Yamane, Fumitaka; Ooigawa, Hidetoshi; Kurita, Hiroki; Ishihara, Shoichiro

    2014-10-01

    Nontraumatic acute subdural hemorrhage (SDH) with intracerebral hemorrhage (ICH) is rare and is usually caused by severe bleeding from aneurysms or arteriovenous fistulas. We encountered a very rare case of spontaneous bleeding from the middle meningeal artery (MMA), which caused hemorrhage in the temporal lobe and subdural space 2 weeks after coil embolization of an ipsilateral, unruptured internal cerebral artery aneurysm in the cavernous portion. At onset, the distribution of hematoma on a computed tomography scan led us to believe that the treated intracavernous aneurysm could bleed into the intradural space. Emergency craniotomy revealed that the dura of the middle fossa was intact except for the point at the foramen spinosum where the exposed MMA was bleeding. Retrospectively, angiography just before and after embolization of the aneurysm did not show any aberrations in the MMA. Although the MMA usually courses on the outer surface of the dura and is unlikely to rupture without an external force, physicians should be aware that the MMA may bleed spontaneously and cause SDH and ICH. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. Endovascular rescue of a fused monorail balloon and cerebral protection device.

    PubMed

    Campbell, John E; Bates, Mark C; Elmore, Michael

    2007-08-01

    To present a case of successful endovascular retrieval of a monorail predilation balloon fused to an embolic protection device (EPD) in the distal internal carotid artery (ICA) of a high-risk symptomatic patient. A 60-year-old man with documented systemic atherosclerotic disease had a severe (>70%) restenosis in the left ICA 3 years after endarterectomy. He was scheduled for carotid artery stenting (CAS) with cerebral protection; however, he developed unstable angina and was transferred to our facility, where the admitting team decided that staged CAS followed by coronary bypass grafting would be the best option. During the CAS procedure, a 6-mm AccuNet filter was passed across the lesion via a 6-F carotid sheath and deployed in the distal ICA without incident. However, the 4-x20-mm predilation monorail balloon was then advanced without visualizing the markers, resulting in inadvertent aggressive interaction that trapped the balloon's tip in the filter. Several maneuvers to separate the devices were unsuccessful. Finally, the filter/balloon combination was moved gently retrograde until the balloon was straddling the subtotal ICA lesion. The lesion was dilated to 4 mm with the balloon, and the sheath was gently advanced across the lesion as the balloon was deflated. Angiography excluded interval occlusion of the filter from the embolic debris during the aforementioned aggressive maneuvers and documented antegrade flow. The filter was slowly withdrawn into the 6-F sheath with simultaneous aspiration. A second 6-mm filter was deployed, and the procedure was completed satisfactorily. The patient did well, with no neurological sequelae. EPDs are an essential in carotid artery stenting and, keeping in mind the potential risks associated with their use, will help the operator avoid complications such as this one.

  5. Novel device and technique for minimally invasive intracerebral hematoma evacuation in the same setting of a ruptured intracranial aneurysm: combined treatment in the neurointerventional angiography suite.

    PubMed

    Turner, Raymond D; Vargas, Jan; Turk, Aquilla S; Chaudry, M Imran; Spiotta, Alejandro M

    2015-03-01

    The presence of intracerebral hematoma from aneurysm rupture is an indication for craniotomy for clot evacuation and aneurysm clipping. Some centers have begun securing aneurysms with coil embolization followed by clot evacuation in the operating room. This approach requires transporting a patient from the angiography suite to the operating room, which can take valuable time and resources. To report our experience with 3 cases in which a novel technique for minimally invasive evacuation of intracerebral hematomas after endovascular treatment of ruptured intracranial aneurysms was used. The Penumbra Apollo system can be used in the angiography suite in conjunction with neuroendovascular techniques to simultaneously address a symptomatic hematoma associated with a ruptured aneurysm. Standard preoperative computed tomography angiography was performed on arrival to the emergency department. The patients underwent diagnostic cerebral angiography followed by balloon-assisted coil embolization and then remained in the neurointerventional suite for intracerebral hematoma evacuation with the Apollo system. All patients tolerated coil embolization and hematoma evacuation well. The combined procedures lasted <3 hours in both cases. Two patients were eventually discharged to acute rehabilitation facilities less than a month after their initial insult, and 1 has been cleared to return to work. The other patient was transferred to hospice care. The Apollo aspiration system appears to be a safe and effective minimally invasive option for intracerebral hematoma evacuation, particularly when coupled with endovascular embolization of ruptured intracranial aneurysms. Future work will address which patient population is most likely to benefit from this promising technique.

  6. Change in Imaging Findings on Angiography-Assisted CT During Balloon-Occluded Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshimatsu, Rika; Yamagami, Takuji, E-mail: yamagami@kochi-u.ac.jp; Ishikawa, Masaki

    2016-06-15

    PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumormore » enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.« less

  7. Onyx embolization of anterior condylar confluence dural arteriovenous fistula

    PubMed Central

    Takemoto, Koichiro; Tateshima, Satoshi; Rastogi, Sachin; Gonzalez, Nestor; Jahan, Reza; Duckwiler, Gary; Vinuela, Fernando

    2013-01-01

    The anterior condylar confluence (ACC) is a small complex venous structure located medial to the jugular vein and adjacent to the hypoglossal canal. To our knowledge, this is the first report of transvenous Onyx embolization for ACC dural arteriovenous fistula (DAVF). Three patients with ACC DAVF were treated using the Onyx liquid embolic agent with or without detachable coils. Complete angiographic obliteration of the fistulas was achieved in all cases without permanent lower cranial neuropathy. This report suggests that the controlled penetration of Onyx is advantageous in order to obliterate ACC DAVFs with a small amount of embolic material. PMID:23459160

  8. Endovascular minimally invasive treatment of the intracranial aneurysms – first 124 cases

    PubMed Central

    Dima, S; Scheau, C; Stefanescu, F; Danaila, L

    2012-01-01

    Introduction: Since May 2005, we have started to treat the intracranial aneurysms endovascular way as an alternative minimally invasive technique to the classic neurosurgery treatment. Objective: Studying the patients’ demographics, clinical presentation, aneurysm size and configuration, type of coils used for embolization, the percentage of compaction and recanalization (especially in patients who presented with subarachnoid hemorrhage), and immediate complications. Methods and Results: An all-inclusive retrospective review of every patient who underwent coils embolization (stent or balloon assisted included) of saccular aneurysms from May 2005 to September 2011 was performed. A total of 116 patients (46 men and 60 women) and 124 aneurysms were treated. A total of 96 patients (41 men and 55 women) underwent follow-up femoral cerebral angiograms (mean follow-up was 25 months and the longest was at 37 months). Five patients required intra-arterial abciximab due to thrombus formation. Four patients had aneurysm rupture while the coil was being advanced. Eleven patients were treated during vasospasm peak. Seven patients had recanalization at 12 months follow-up. Discussion: The average hospitalization period was of 4 days. There is a close relation between Hunt and Hess scale score before treatment and post interventional neurological status. Due to subarachnoid hemorrhage, the vasospasm remains a threat to the patient’s neurological status. The treatment of cerebral aneurysms with endosacular embolization by coils is a safe and durable option. The risk of recanalization or re-rupture in our cohort is small compared to series published elsewhere. Larger series of patients are needed to support our evidence. PMID:23049642

  9. Endovascular minimally invasive treatment of the intracranial aneurysms--first 124 cases.

    PubMed

    Dima, S; Scheau, C; Stefanescu, F; Danaila, L

    2012-09-15

    Since May 2005, we have started to treat the intracranial aneurysms endovascular way as an alternative minimally invasive technique to the classic neurosurgery treatment. Studying the patients' demographics, clinical presentation, aneurysm size and configuration, type of coils used for embolization, the percentage of compaction and recanalization (especially in patients who presented with subarachnoid hemorrhage), and immediate complications. An all-inclusive retrospective review of every patient who underwent coils embolization (stent or balloon assisted included) of saccular aneurysms from May 2005 to September 2011 was performed. A total of 116 patients (46 men and 60 women) and 124 aneurysms were treated. A total of 96 patients (41 men and 55 women) underwent follow-up femoral cerebral angiograms (mean follow-up was 25 months and the longest was at 37 months). Five patients required intra-arterial abciximab due to thrombus formation. Four patients had aneurysm rupture while the coil was being advanced. Eleven patients were treated during vasospasm peak. Seven patients had recanalization at 12 months follow-up. The average hospitalization period was of 4 days. There is a close relation between Hunt and Hess scale score before treatment and post interventional neurological status. Due to subarachnoid hemorrhage, the vasospasm remains a threat to the patient's neurological status. The treatment of cerebral aneurysms with endosacular embolization by coils is a safe and durable option. The risk of recanalization or re-rupture in our cohort is small compared to series published elsewhere. Larger series of patients are needed to support our evidence.

  10. Evaluation of previously embolized intracranial aneurysms: inter-and intra-rater reliability among neurosurgeons and interventional neuroradiologists.

    PubMed

    Zuckerman, Scott L; Lakomkin, Nikita; Magarik, Jordan A; Vargas, Jan; Stephens, Marcus; Akinpelu, Babatunde; Spiotta, Alejandro M; Ahmed, Azam; Arthur, Adam S; Fiorella, David; Hanel, Ricardo; Hirsch, Joshua A; Hui, Ferdinand K; James, Robert F; Kallmes, David F; Meyers, Philip M; Niemann, David B; Rasmussen, Peter; Turner, Raymond D; Welch, Babu G; Mocco, J

    2018-05-01

    The angiographic evaluation of previously coiled aneurysms can be difficult yet remains critical for determining re-treatment. The main objective of this study was to determine the inter-rater reliability for both the Raymond Scale and per cent embolization among a group of neurointerventionalists evaluating previously embolized aneurysms. A panel of 15 neurointerventionalists examined 92 distinct cases of immediate post-coil embolization and 1 year post-embolization angiographs. Each case was presented four times throughout the study, along with alterations in demographics in order to evaluate intra-rater reliability. All respondents were asked to provide the per cent embolization (0-100%) and Raymond Scale grade (1-3) for each aneurysm. Inter-rater reliability was evaluated by computing weighted kappa values (for the Raymond Scale) and intraclass correlation coefficients (ICC) for per cent embolization. 10 neurosurgeons and 5 interventional neuroradiologists evaluated 368 simulated cases. The agreement among all readers employing the Raymond Scale was fair (κ=0.35) while concordance in per cent embolization was good (ICC=0.64). Clinicians with fewer than 10 years of experience demonstrated a significantly greater level of agreement than the group with greater than 10 years (κ=0.39 and ICC=0.70 vs κ=0.28 and ICC=0.58). When the same aneurysm was presented multiple times, clinicians demonstrated excellent consistency when assessing per cent embolization (ICC=0.82), but moderate agreement when employing the Raymond classification (κ=0.58). Identifying the per cent embolization in previously coiled aneurysms resulted in good inter- and intra-rater agreement, regardless of years of experience. The strong agreement among providers employing per cent embolization may make it a valuable tool for embolization assessment in this patient population. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights

  11. CE-MRA for Follow-up of Aneurysms Post Stent-Assisted Coiling

    PubMed Central

    Agid, R.; Schaaf, M.; Farb, RI.

    2012-01-01

    Summary This study compared the accuracy of contrast-enhanced MR angiography (CE-MRA) to intra-arterial cerebral angiography (IA-DSA) for assessment of intracranial aneurysms after stent-assisted coiling and to check if the presence of a stent in the parent artery diminishes the accuracy of CE-MRA. Consecutive patients with cerebral aneurysms treated by stent-assisted coiling were evaluated retrospectively. Matching follow-up CE-MRA and IA-DSA were evaluated separately. Evaluation included the presence of aneurysmal remnant, patency and stenosis of parent artery. Twenty-seven patients with 28 aneurysms and 33 matched CE-MRA and IA-DSA studies were evaluated. Nineteen aneurysmal remnants were seen on CE-MRA and 16 on IA-DSA. CE-MRA diagnosed three aneurysmal remnants not appreciated on IA-DSA. Five other remnants were larger on CE-MRA than IA-DSA. None of the remnants were missed on CE-MRA. Parent arteries were patent on both modalities. CE-MRA showed false stenosis of the stented artery in six cases and exaggerated stenosis in two. In 18 cases, CE-MRA showed a short focal “pseudo-stenosis” where the stent’s marker bands were located. This was noted whenever the stent’s marker bands were located in an artery with luminal diameter ≤2 mm and was called “marker band effect”. CE-MRA is an accurate technique for follow-up of aneurysms post stent-assisted coiling with excellent depiction of remnants in spite of the presence of a stent. Apparent stenosis of the stented parent artery on CE-MRA is often false or exaggerated. “Marker band effect” should be recognized as an artifact that appears when stent’s marker bands are in a small artery. PMID:22958765

  12. Perianeurysm edema with second-generation bioactive coils.

    PubMed

    Marden, Franklin A; Putman, Christopher M

    2008-06-01

    Perianeurysm edema is an uncommon complication of intracranial aneurysms, occurring mostly in giant aneurysms that suddenly thrombose. We present the first report of an unruptured, nongiant, saccular aneurysm that developed marked perianeurysm edema after embolization with Matrix2 coils. In this case, follow-up catheter angiography showed a new coil tail protruding beyond the dome of the aneurysm in the region of the most intense edema. We postulate that perianeurysm edema may occur after breakdown of the aneurysm wall accompanied by an inflammatory response to exposed bioactive coils. Clinicians should be aware of this potential complication and consider performing earlier surveillance angiography when this occurs to ensure that there has not been a shift in the coil mass and recurrence of the aneurysm.

  13. Septic pulmonary arteriovenous fistula. An unusual conduit for systemic embolization in right-sided valvular endocarditis.

    PubMed

    Stagaman, D J; Presti, C; Rees, C; Miller, D D

    1990-06-01

    Right-sided valvular (tricuspid, pulmonic) endocarditis is frequently complicated by septic pulmonary embolization. Systemic embolization may also rarely occur due to associated left-sided endocarditis or right-to-left shunting in patients with septal defects. This report documents the occurrence of systemic embolization causing a cerebrovascular accident in an intravenous drug abuser with recurrent tricuspid valve endocarditis due to an isolated peripheral septic pulmonary arteriovenous fistula. Noninvasive diagnosis of the fistula by cardiac auscultation, contrast echocardiography, and nuclear magnetic resonance imaging was confirmed by selective pulmonary angiography. Subselective balloon embolization of the pulmonary arteries feeding this fistula was accomplished.

  14. Preoperative Embolization of Skull Base Meningiomas: Outcomes in the Onyx Era.

    PubMed

    Przybylowski, Colin J; Baranoski, Jacob F; See, Alfred P; Flores, Bruno C; Almefty, Rami O; Ding, Dale; Chapple, Kristina M; Sanai, Nader; Ducruet, Andrew F; Albuquerque, Felipe C

    2018-05-09

    Preoperative embolization may facilitate skull base meningioma resection, but its safety and efficacy in the Onyx era have not been investigated. In this retrospective cohort study, we evaluated the outcomes of preoperative embolization of skull base meningiomas using Onyx as the primary embolysate. We queried an endovascular database for patients with skull base meningiomas who underwent preoperative embolization at our institution in 2007-2017. Patient, tumor, procedure, and outcome data were analyzed. Twenty-eight patients (28 meningiomas) underwent successful preoperative meningioma embolization. The mean patient age ± SD was 56 ± 13 years, and 18 patients (64%) were women. The mean tumor size was 49 cm 3 . There were 1, 2, or 3 arterial pedicles embolized in 21 cases (75%), 6 cases (21%), and 1 case (4%), respectively. The embolized pedicles included branches of the middle meningeal artery in 19 cases (68%), the internal maxillary artery in 8 cases (29%), the ascending pharyngeal artery in 2 cases (7%), and the posterior auricular, ophthalmic, occipital, and anterior cerebral arteries in 1 case each (4%). The embolysates used were Onyx alone in 20 cases (71%), n-butyl cyanoacrylate alone in 3 cases (11%), coils/particles and Onyx/n-butyl cyanoacrylate in 2 cases each (7%), and Onyx and coils in 1 case (4%). The median degree of tumor devascularization was 60%. Significant neurologic morbidity occurred in 1 patient (4%) who developed symptomatic peritumoral edema after Onyx embolization. For appropriately selected skull base meningiomas supplied by dura mater-based arterial pedicles without distal cranial nerve supply, preoperative embolization with current embolysate technology affords substantial tumor devascularization with a low complication rate. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Alternative Treatment for Bleeding Peristomal Varices: Percutaneous Parastomal Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pabon-Ramos, Waleska M., E-mail: waly.pr@duke.edu; Niemeyer, Matthew M.; Dasika, Narasimham L., E-mail: narasimh@med.umich.edu

    2013-10-15

    Purpose: To describe how peristomal varices can be successfully embolized via a percutaneous parastomal approach. Methods: The medical records of patients who underwent this procedure between December 1, 2000, and May 31, 2008, were retrospectively reviewed. Procedural details were recorded. Median fluoroscopy time and bleeding-free interval were calculated. Results: Seven patients underwent eight parastomal embolizations. The technical success rate was 88 % (one failure). All embolizations were performed with coils combined with a sclerosant, another embolizing agent, or both. Of the seven successful parastomal embolizations, there were three cases of recurrent bleeding; the median time to rebleeding was 45 daysmore » (range 26-313 days). The remaining four patients did not develop recurrent bleeding during the follow-up period; their median bleeding-free interval was 131 days (range 40-659 days). Conclusion: This case review demonstrated that percutaneous parastomal embolization is a feasible technique to treat bleeding peristomal varices.« less

  16. Use of Intermediate Guide Catheters as an Adjunct in Extracranial Embolization to Avoid Onyx Reflux into the Anastomotic Vasculature

    PubMed Central

    Puri, Ajit S; Kühn, Anna L; Hou, Samuel Y; Wakhloo, Ajay K

    2014-01-01

    Summary Onyx is a non-adhesive polymer used for embolization of arteriovenous malformations and dural arteriovenous fistulas (DAVFs). The limiting factor for Onyx embolization is usually the amount of microcatheter reflux, which can be safely tolerated. The dual microcatheter technique, compliant balloon use proximally and the use of the dual lumen Scepter balloon have been described to prevent and limit proximal Onyx reflux. We describe the use the Navien 058 intermediate guide catheter to accept the Onyx reflux in its lumen and possibly also serve as a mechanical barrier to avoid reflux into the anastomotic channel connecting the occipital artery to the vertebral artery during DAVF embolization via the occipital artery. Complete embolization of the DAVF was achieved using the lumen of the Navien catheter to accept aggressive Onyx reflux. Complete cure of the DAVF was obtained with Onyx cast filling the entire venous pouch. Besides providing distal access support, intermediate guide catheters can also prevent embolic material reflux by accepting reflux into the lumen and providing a mechanical barrier. PMID:25207904

  17. Closed-Cell Stent-Assisted Coiling of Intracranial Aneurysms: Evaluation of Changes in Vascular Geometry Using Digital Subtraction Angiography.

    PubMed

    Beller, Ebba; Klopp, David; Göttler, Jens; Kaesmacher, Johannes; Zimmer, Claus; Kirschke, Jan S; Prothmann, Sascha

    2016-01-01

    Stent-assisted coil embolization (SACE) plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms. 31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and afferent vessel, and angle between afferent and efferent vessel close to (δ1), respectively, more remote from the aneurysm neck (δ2) were graphically determined in 2D angiography projections. Stent assisted coiling resulted in a significant increase of all three angles from a mean value (±SEM) of α = 119° (±6.5°) pretreatment to 130° (±6.6°) posttreatment (P ≤ .001), δ1 = 129° (±6.4°) to 139° (±6.1°), (P ≤ .001) and δ2 = 115° (±8.4°) to 126° (±7.5°), (P ≤ .01). Angular change of δ1 in AcomA aneurysms was significant greater compared to sidewall aneurysms (26°±4.9° versus 8°± 2.3°, P ≤ .05). The initial angle of δ1 and δ2 revealed a significantly inverse relationship to the angle increase (δ1: r = -0.41, P ≤ .05 and δ2: r = -0.47, P ≤ .01). Moreover, angle δ1 was significantly higher in unruptured compared to ruptured aneurysms (135°±7.1° versus 103°±10.8°, P ≤ .05). Stent deployment modulates the geometry of the aneurysm-vessel complex, which may lead to favorable hemodynamic changes more similar to unruptured than to ruptured aneurysms. Our findings also suggest that the more acute-angled aneurysm-vessel anatomy, the larger the angular change. Further studies are needed to investigate whether these changes improve the clinical outcome.

  18. Closed-Cell Stent-Assisted Coiling of Intracranial Aneurysms: Evaluation of Changes in Vascular Geometry Using Digital Subtraction Angiography

    PubMed Central

    Beller, Ebba; Klopp, David; Göttler, Jens; Kaesmacher, Johannes; Zimmer, Claus; Kirschke, Jan S.; Prothmann, Sascha

    2016-01-01

    Background Stent-assisted coil embolization (SACE) plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms. Methods 31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and afferent vessel, and angle between afferent and efferent vessel close to (δ1), respectively, more remote from the aneurysm neck (δ2) were graphically determined in 2D angiography projections. Results Stent assisted coiling resulted in a significant increase of all three angles from a mean value (±SEM) of α = 119° (±6.5°) pretreatment to 130° (±6.6°) posttreatment (P ≤ .001), δ1 = 129° (±6.4°) to 139° (±6.1°), (P ≤ .001) and δ2 = 115° (±8.4°) to 126° (±7.5°), (P ≤ .01). Angular change of δ1 in AcomA aneurysms was significant greater compared to sidewall aneurysms (26°±4.9° versus 8°± 2.3°, P ≤ .05). The initial angle of δ1 and δ2 revealed a significantly inverse relationship to the angle increase (δ1: r = -0.41, P ≤ .05 and δ2: r = -0.47, P ≤ .01). Moreover, angle δ1 was significantly higher in unruptured compared to ruptured aneurysms (135°±7.1° versus 103°±10.8°, P ≤ .05). Conclusion Stent deployment modulates the geometry of the aneurysm-vessel complex, which may lead to favorable hemodynamic changes more similar to unruptured than to ruptured aneurysms. Our findings also suggest that the more acute-angled aneurysm-vessel anatomy, the larger the angular change. Further studies are needed to investigate whether these changes improve the clinical outcome. PMID:27073908

  19. Detection Rate and Clinical Relevance of Ink Tattooing during Balloon-Assisted Enteroscopy

    PubMed Central

    Ebigbo, A.; Schrempf, M.; Messmann, H.; Gölder, S. K.

    2017-01-01

    Background and Aims Balloon-assisted enteroscopy (BAE) is a well-established tool in the diagnosis and therapy of small bowel diseases. Ink tattooing of the small bowel is used to mark pathologic lesions or the depth of small bowel insertion. The purpose of this study was to determine the safety, the detection rate, and the clinical relevance of ink tattooing during BAE. Methods We performed a retrospective analysis of all 81 patients who received an ink tattooing during BAE between 2010 and 2015. Results In all patients, ink tattooing was performed with no complications. 26 patients received a capsule endoscopy after BAE. The tattoo could be detected via capsule endoscopy in 19 of these 26 patients. The tattoo of the previous BAE could be detected via opposite BAE in 2 of 11 patients. In 9 patients, ink tattooing influenced the choice of approach for reenteroscopy. In 7 patients, the tattoo was used for intraoperative localization and in 3 patients for intraoperative localization as well as for reenteroscopy. The intraoperative detection rate of the tattoo was 100%. Conclusion Ink tattooing of the small intestine is a safe endoscopic procedure to mark the depth of scope insertion or a pathologic lesion during balloon-assisted enteroscopy. PMID:29230241

  20. Splenic Arterial Embolization in the Treatment of Severe Portal Hypertension Due to Pancreatic Diseases: The Primary Experience in 14 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Qi, E-mail: wqtjmu@gmail.com; Xiong, Bin, E-mail: herrxiong@126.com; Zheng, ChuanSheng, E-mail: hqzcsxh@sina.com

    ObjectiveThis retrospective study reports our experience using splenic arterial particle embolization and coil embolization for the treatment of sinistral portal hypertension (SPH) in patients with and without gastric bleeding.MethodsFrom August 2009 to May 2012, 14 patients with SPH due to pancreatic disease were diagnosed and treated with splenic arterial embolization. Two different embolization strategies were applied; either combined distal splenic bed particle embolization and proximal splenic artery coil embolization in the same procedure for acute hemorrhage (1-step) or interval staged distal embolization and proximal embolization in the stable patient (2-step). The patients were clinically followed.ResultsIn 14 patients, splenic arterial embolizationmore » was successful. The one-step method was performed in three patients suffering from massive gastric bleeding, and the bleeding was relieved after embolization. The two-step method was used in 11 patients, who had chronic gastric variceal bleeding or gastric varices only. The gastric varices disappeared in the enhanced CT scan and the patients had no gastric bleeding during follow-up.ConclusionsSplenic arterial embolization, particularly the two-step method, proved feasible and effective for the treatment of SPH patients with gastric varices or gastric variceal bleeding.« less

  1. Impending rupture of saphenous vein graft aneurysm with floating fractured bare metal stent treated by coil embolization and covered stent implantation.

    PubMed

    Kodama, Atsuko; Kurita, Tairo; Kato, Osamu; Suzuki, Takahiko

    2016-11-01

    Aneurysmal degeneration of a saphenous vein graft (SVG) is a rare, but potentially fatal complication of coronary artery bypass graft (CABG) surgery. In this case report, a patient that had undergone prior CABG surgery and bare metal stent (BMS) implantation at the site of a stenotic SVG lesion presented at our hospital with chest pain, and an SVG aneurysm was detected at the previous BMS implantation site. In addition, the implanted BMS was fractured and floating in the SVG aneurysm. The SVG aneurysm was successfully occluded by percutaneous intervention, using a combination of distal covered stent deployment at the site of the anastomosis between the native coronary artery and the SVG and proximal coil embolization of the aneurysm.

  2. Innovations and techniques for balloon-enteroscope-assisted endoscopic retrograde cholangiopancreatography in patients with altered gastrointestinal anatomy

    PubMed Central

    Yamauchi, Hiroshi; Kida, Mitsuhiro; Imaizumi, Hiroshi; Okuwaki, Kosuke; Miyazawa, Shiro; Iwai, Tomohisa; Koizumi, Wasaburo

    2015-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) remains challenging in patients who have undergone surgical reconstruction of the intestine. Recently, many studies have reported that balloon-enteroscope-assisted ERCP (BEA-ERCP) is a safe and effective procedure. However, further improvements in outcomes and the development of simplified procedures are required. Percutaneous treatment, Laparoscopy-assisted ERCP, endoscopic ultrasound-guided anterograde intervention, and open surgery are effective treatments. However, treatment should be noninvasive, effective, and safe. We believe that these procedures should be performed only in difficult-to-treat patients because of many potential complications. BEA-ERCP still requires high expertise-level techniques and is far from a routinely performed procedure. Various techniques have been proposed to facilitate scope insertion (insertion with percutaneous transhepatic biliary drainage (PTBD) rendezvous technique, Short type single-balloon enteroscopes with passive bending section, Intraluminal injection of indigo carmine, CO2 inflation guidance), cannulation (PTBD or percutaneous transgallbladder drainage rendezvous technique, Dilation using screw drill, Rendezvous technique combining DBE with a cholangioscope, endoscopic ultrasound-guided rendezvous technique), and treatment (overtube-assisted technique, Short type balloon enteroscopes) during BEA-ERCP. The use of these techniques may allow treatment to be performed by BEA-ERCP in many patients. A standard procedure for ERCP yet to be established for patients with a reconstructed intestine. At present, BEA-ERCP is considered the safest and most effective procedure and is therefore likely to be recommended as first-line treatment. In this article, we discuss the current status of BEA-ERCP in patients with surgically altered gastrointestinal anatomy. PMID:26074685

  3. Microcatheter Embolization of Intractable Idiopathic Epistaxis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leppaenen, Martti; Seppaenen, Seppo; Laranne, Jussi

    1999-11-15

    Purpose: To assess the efficacy and safety of microcatheter embolization in the treatment of intractable idiopathic epistaxis. Methods: Thirty-seven patients underwent microcatheter embolization in 1991-1998. We evaluated retrospectively the technical and clinical outcome, the number of complications, the duration of embolization in each case, and the number of blood transfusions needed. All embolizations were done with biplane digital subtraction angiography (DSA) equipment. The procedure was carried out under local anesthesia using transfemoral catheterization, except in one case where the translumbar route was used. Tracker 18 or 10 microcatheters were advanced as far as possible to the distal branches of themore » sphenopalatine artery. Polyvinyl alcohol (PVA) particles were used for embolization in most cases, while platinum coils or a combination of these two materials were occasionally used. The primary outcome was always assessed immediately by angiography. Follow-up data were obtained from patient records, by interviewing patients on the telephone or by postal questionnaires when necessary. The mean follow-up time was 21 months. Results: The embolization was technically successful in all 37 cases. A curative outcome was achieved in 33 cases (89%). The mean duration of the procedure was 110 min. Four patients (8%) had mild transient complications, but no severe or persistent complications were encountered. Twenty-three patients needed a blood transfusion. Slight rebleeding occurred in three patients during the follow-up; all responded to conservative treatment. One patient suffered two episodes of rebleeding within 2 months after primary embolization. Re-embolizations successfully stopped the bleeding. Conclusion: Embolization is the primary invasive modality for treating intractable idiopathic epistaxis. It proved both safe and effective over a relatively long follow-up.« less

  4. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pua, Uei, E-mail: druei@yahoo.com

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  5. [Selective embolization to treat obstetric hemorrhage].

    PubMed

    Ferrer Puchol, M D; Lanciego, C; Esteban, E; Ciampi, J J; Edo, M A; Ferragud, S

    2014-01-01

    To describe cases of obstetric hemorrhage that have called for selective intra-arterial embolization and the different embolization techniques used. To assess the clinical outcomes and postprocedural fertility. We studied 27 women with obstetric hemorrhage. In 24 patients, embolization was performed by catheterizing both uterine arteries and in 2 patients only one uterine artery was catheterized (pseudoaneurysm). The materials used for embolization consisted of Spongostan in 17/27, particles in 9/27, and coils in 1/27. Clinical follow-up included an analysis of early and late complications and of postprocedural fertility. Hemorrhage was classified as primary (25/27) or secondary (2/27). The cause of bleeding was vaginal delivery (20), cesarean sections (5), abortion (1), and cervical ectopic pregnancy (1). The initial technical success rate was 100% and the clinical success rate was 92.6% (25 of the 27 patients). Bleeding ceased and the outcome was satisfactory in 25 patients. During clinical follow-up ranging from one to seven years, 23 patients had normal menstruation and 6 patients completed 7 full-term pregnancies. Intra-arterial embolization for obstetric hemorrhage leads to good outcomes and few complications and it preserves fertility. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  6. Use of intermediate guide catheters as an adjunct in extracranial embolization to avoid onyx reflux into the anastomotic vasculature. A technical note.

    PubMed

    Puri, Ajit S; Kühn, Anna L; Hou, Samuel Y; Wakhloo, Ajay K

    2014-01-01

    Onyx is a non-adhesive polymer used for embolization of arteriovenous malformations and dural arteriovenous fistulas (DAVFs). The limiting factor for Onyx embolization is usually the amount of microcatheter reflux, which can be safely tolerated. The dual microcatheter technique, compliant balloon use proximally and the use of the dual lumen Scepter balloon have been described to prevent and limit proximal Onyx reflux. We describe the use the Navien 058 intermediate guide catheter to accept the Onyx reflux in its lumen and possibly also serve as a mechanical barrier to avoid reflux into the anastomotic channel connecting the occipital artery to the vertebral artery during DAVF embolization via the occipital artery. Complete embolization of the DAVF was achieved using the lumen of the Navien catheter to accept aggressive Onyx reflux. Complete cure of the DAVF was obtained with Onyx cast filling the entire venous pouch. Besides providing distal access support, intermediate guide catheters can also prevent embolic material reflux by accepting reflux into the lumen and providing a mechanical barrier.

  7. Resuscitative endovascular balloon occlusion of the aorta may increase the bleeding of minor thoracic injury in severe multiple trauma patients: a case report.

    PubMed

    Maruhashi, Takaaki; Minehara, Hiroaki; Takeuchi, Ichiro; Kataoka, Yuichi; Asari, Yasushi

    2017-12-14

    The resuscitative endovascular balloon occlusion of the aorta, because of its efficacy and feasibility, has been widely used in treating patients with severe torso trauma. However, complications developing around the site proximal to the occlusion by resuscitative endovascular balloon occlusion of the aorta have almost never been studied. A 50-year-old Japanese woman fell from a height of approximately 10 m. At initial arrival, her respiratory rate was 24 breaths/minute, her blood oxygen saturation was 95% under 10 L/minute oxygenation, her pulse rate was 90 beats per minute, and her blood pressure was 180/120 mmHg. Mild lung contusion, hemopneumothorax, unstable pelvic fracture, and retroperitoneal bleeding with extravasation of contrast media were observed in initial computed tomography. As her vital signs had deteriorated during computed tomography, a 7-French aortic occlusion catheter (RESCUE BALLOON®, Tokai Medical Products, Aichi, Japan) was inserted and inflated for aortic occlusion at the first lumbar vertebra level and transcatheter arterial embolization was performed for the pelvic fracture. Her bilateral internal iliac arteries were embolized with a gelatin sponge; however, the embolized sites presented recanalization as coagulopathy appeared. Her bilateral internal iliac arteries were re-embolized by n-butyl-2-cyanoacrylate. The balloon was deflated 18 minutes later. After embolization, repeat computed tomography was performed and a massive hemothorax, which had not been captured on arrival, had appeared in her left pleural cavity. Thoracotomy hemostasis was performed and a hemothorax of approximately 2500 ml was aspirated to search for the source of bleeding. However, clear active bleeding was not captured; resuscitative endovascular balloon occlusion of the aorta may have been the cause of the increased bleeding of the thoracic injury at the proximal site of the aorta occlusion. It is necessary to note that the use of resuscitative endovascular

  8. Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bagla, Sandeep, E-mail: sandeep.bagla@gmail.com; Smirniotopoulos, John; Orlando, Julie C.

    PurposeProstatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH.Materials and MethodsIRB-approved retrospective study of 40 consecutive patients 49–81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performedmore » within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months.ResultsNo significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm{sup 2} vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred.ConclusionsRobotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.« less

  9. Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis.

    PubMed

    Bagla, Sandeep; Smirniotopoulos, John; Orlando, Julie C; Piechowiak, Rachel

    2017-03-01

    Prostatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH. IRB-approved retrospective study of 40 consecutive patients 49-81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months. No significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm 2 vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred. Robotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

  10. Trans-arterial Onyx Embolization of a Functional Thoracic Paraganglioma

    PubMed Central

    Chacón-Quesada, Tatiana; Maud, Alberto; Ramos-Duran, Luis; Torabi, Alireza; Fitzgerald, Tamara; Akle, Nassim; Cruz Flores, Salvador; Trier, Todd

    2015-01-01

    Paragangliomas are rare tumors of the endocrine system. They are highly vascular and in some cases hormonally active, making their management challenging. Although there is strong evidence of the safety and effectiveness of preoperative embolization in the management of spinal tumors, only five cases have been reported in the setting of thoracic paragangliomas. We present the case of a 19-year-old man with a large, primary, functional, malignant paraganglioma of the thoracic spine causing a vertebral fracture and spinal cord compression. To our knowledge this is the first report of preoperative trans-arterial balloon augmented Onyx embolization of a thoracic paraganglioma. PMID:25763296

  11. Percutaneous Glue Embolization of a Visceral Artery Pseudoaneurysm in a Case of Sickle Cell Anemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gulati, Gurpreet S.; Gulati, Manpreet S.; Makharia, Govind

    2006-08-15

    Although aneurysmal complications of sickle cell anemia have been described in the intracranial circulation, visceral artery pseudoaneurysms in this disease entity have not previously been reported in the literature. Conventional treatment of visceral pseudoaneurysms has been surgical ligation or resection of the aneurysm. Transcatheter embolization has emerged as an attractive, minimally invasive alternative to surgery in the treatment of these lesions. In certain situations, however, due to the unfavorable angiographic anatomy precluding safe transcatheter embolization, direct percutaneous glue injection of the pseudoaneurysm sac may be considered to achieve successful occlusion of the sac. The procedure may be rendered safer bymore » simultaneous balloon protection of the parent artery. We describe this novel treatment modality in a case of inferior pancreaticoduodenal artery pseudoaneurysm in a patient with sickle cell anemia. Although a complication in the form of glue reflux into the parent vessel occurred that necessitated surgery, this treatment modality may be used in very selected cases (where conventional endovascular embolization techniques are not applicable) after careful selection of the balloon diameter and appropriate concentration of the glue-lipiodol mixture.« less

  12. Transarterial Embolization of a Renal Artery Aneurysm Concomitant With Renal Arteriovenous Fistula.

    PubMed

    Hongsakul, Keerati; Bannangkoon, Kittipitch; Boonsrirat, Ussanee; Kritpracha, Boonprasit

    2018-01-01

    Congenital renal artery aneurysm is uncommon. Moreover, renal artery aneurysm concomitant with a congenital renal arteriovenous fistula is extremely rare. Transarterial embolization is the first-line treatment for these conditions. We report a case of a patient with congenital renal artery aneurysm concomitant with a congenital renal arteriovenous fistula of the upper polar left renal artery which was successfully treated by transarterial embolization with coil, glue, and Amplatzer vascular plug.

  13. Transvenous Endovascular Treatment for Scalp Arteriovenous Fistulas: Results with Combined Use of Onyx and Coils.

    PubMed

    Ni, Wei; Tian, Yanlong; Gu, Yuxiang; Mao, Ying

    2017-11-01

    Scalp arteriovenous fistulas (AVFs) are rare lesions that may occur spontaneously or secondary to head trauma. A standard treatment strategy for these lesions has not been established to date. We present 3 cases of successful treatment of scalp AVFs using a combination of Onyx-18 and coils via a transvenous approach. The patient database at Huashan Hospital, Fudan University, Shanghai, China was reviewed, and patients with scalp AVFs treated with Onyx-18 and coils via a transvenous approach were identified for analysis. Between 2014 and 2016, 3 consecutive patients with scalp AVFs were treated transvenously with Onyx embolization in combination with coil placement at our hospital. No procedure-related complications were noted. Postembolization angiography demonstrated successful and complete occlusion of the AVFs immediately after treatment. Clinical follow-up showed resolution of symptoms. The technique of transvenous "armored concrete" embolization using a combination of coils and Onyx is an effective treatment modality for scalp AVFs, particularly in type C cases. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. The endovascular treatment of a spinal perimedullary arteriovenous fistula with coils: a case report.

    PubMed

    Pasqualetto, L; Papa, R; Isalberti, M; Nuzzi, N P; Branca, V

    2011-03-01

    We report a case of direct spinal intradural ventral arteriovenous fistula of the thoraco-lumbar region. Angiography demonstrated a single feeder from the anterior spinal artery that drained directly into a markedly dilated vein without an intervening nidus. The endovascular treatment was performed by a transarterial approach and the occlusion of the fistula, after a failed treatment by a detachable balloon, was obtained by coils released in the initial fistulous site inside a venous dilatation with complete clinical cure. This case indicates that endovascular treatment is possible using coils as a valid and safe alternative to a balloon, glue or surgical approach.

  15. A coil placement technique to treat intracranial aneurysm with incorporated artery.

    PubMed

    Luo, Chao-Bao; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2018-03-01

    Endovascular coil embolization is an accepted treatment option for intracranial aneurysms. However, the coiling of aneurysms with an incorporated artery (IA) poses a high risk of IA occlusion. Here we report our experience of endovascular coil placement using a technique that avoids IA occlusion in aneurysms with IAs. Over a 6-year period, 185 patients harboring 206 intracranial aneurysms underwent endosaccular coiling. Forty-two of these patients with 45 aneurysms were treated by coil placement to avoid IAs occlusion. We assessed the anatomy of the aneurysms and IAs, technical feasibility of the procedure, and degree of aneurysm occlusion. Clinical and angiographic outcomes were assessed as well. Aneurysms were located in the supra-clinoid intracranial internal carotid artery (n = 24), anterior cerebral artery (n = 6), middle cerebral artery (n = 7), and vertebrobasilar artery (n = 8). The IA was at the aneurysm neck in 34 patients, body in 10, and dome in 1. Immediate post-coiling angiogram showed preservation of blood flow through the IA in all aneurysms. Coil compaction with aneurysmal regrowth was found in 7 of 36 patients having follow-up conventional angiography. One patient had an IA territory infarction after embolization. All 42 patients were followed up (mean: 21 months) and showed no re-bleeding. This technique is effective and safe in managing intracranial aneurysms with IAs. Although aneurysmal recurrence may occur in some aneurysms because of insufficient coiling, this technique is simpler to perform and requires less skill than other techniques. It can be an alternative option for treating some selected intracranial aneurysms with IAs. Copyright © 2017. Published by Elsevier Taiwan LLC.

  16. High-grade traumatic torso visceral injury with hemodynamic instability: effectiveness of transarterial embolization using n-butyl cyanoacrylate.

    PubMed

    Tsurukiri, Junya; Ohta, Shoichi; Hoshiai, Akira; Sano, Hidefumi; Okumura, Eitaro; Tsubouchi, Nobuhiko; Konishi, Hiroyuki; Yukioka, Tetsuo

    2017-04-01

    Trauma patients with uncontrolled hemorrhage encountering coagulopathy are often associated with poor outcome. Recently, the concept of damage control interventional radiology, which focuses on "speedy stoppage of bleeding" by interventional radiology among trauma patients with hemodynamic instability and acute traumatic coagulopathy, was proposed as an alternative to damage control surgery. N-butyl cyanoacrylate (NBCA) has been used as a liquid embolic agent in various non-traumatic situations, where it has been shown to have a high technical success rate and low recurrent bleeding rate, especially in patients with coagulopathy. In this case, we treated a young patient with hemodynamic instability caused by a high-grade hepatic injury, who underwent arterial embolization (AE) using NBCA assisted with resuscitative endovascular balloon occlusion of the aorta and achieved successful hemostasis. A review of published works using PUBMED was carried out, and 10 published reports involving 23 trauma patients who underwent AE using NBCA were identified. Among them, only four reports involving five trauma patients with torso visceral injuries were identified. Three of five patients who were hemodynamically unstable underwent AE using NBCA, resulting in the stabilization of hemodynamics. We concluded that AE with resuscitative endovascular balloon occlusion of the aorta as a damage control interventional radiology procedure might be acceptable for the hemodynamically unstable hepatic injury, and NBCA could be one of the effective hemostatic agents for this purpose, in cases of trauma-induced coagulopathy.

  17. Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with Enterprise and Neuroform stents: a comparative analysis of the literature.

    PubMed

    King, Brent; Vaziri, Sasha; Singla, Amit; Fargen, Kyle M; Mocco, J

    2015-12-01

    The most widely used intracranial stents for stent-assisted coiling are Neuroform (NEU) and Enterprise stents (ENT). This study compares published outcomes between the ENT and NEU coil-assist systems and comments on the published safety and efficacy of stent-assisted coiling in general. A literature search was performed through PubMed for all published series of ENT or NEU stent-assisted coiling of cerebral aneurysms from 2004 to 2014. All studies including 10 or more published cases of stent-assisted coiling with ENT or NEU were included. 47 studies met the inclusion criteria, containing 4238 aneurysms in 4039 patients. 2111 aneurysms were treated with NEU and 2127 were treated with ENT. Mean follow-up was 14.1 months. Overall, thromboembolic events occurred in 6.4% of aneurysms, intracranial hemorrhage (ICH) in 2.6%, permanent morbidity in 3.9%, and mortality in 2.3%. Initial and final 100% angiographic occlusion was seen in 53% and 69% of patients, respectively. Deployment failures (p<0.001), ICH (p=0.001), mortality among all patients (p=0.03), and recanalization (p=0.02) were more commonly reported in NEU treated aneurysms. The ENT system was also associated with higher reported complete occlusion at follow-up (p<0.001). This literature review represents the largest and most robust comparison of stent-assisted coiling devices to date, containing over 4200 aneurysms in more than 4000 patients. Comparative analyses demonstrate that both devices are reported to be safe and effective with comparable permanent morbidity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Long-term follow-up of aneurysms treated electively with woven stent-assisted coiling.

    PubMed

    Cheung, Nicholas K; Chiu, Albert Hy; Cheung, Andrew K; Wenderoth, Jason D

    2017-12-15

    Preliminary short-term results for stent-assisted coil embolization (SACE) using woven/braided stents have been promising. However, evidence supporting mid- to long-term efficacy and durability is lacking. To report the long-term results for the durability of elective intracranial aneurysms treated with woven stents. Between May 2012 and May 2015, 98 consecutive patients with 103 aneurysms underwent elective woven SACE across three Australian neurovascular centres. All patients had immediate, 6- and 18-month clinical and radiological follow-up. Radiological assessment was performed with modified Raymond-Roy occlusion scores based on angiography results, while clinical assessment was based on the modified Rankin Scale. Six-month follow-up was available in 100 aneurysms, and an 18-month follow-up in 97 aneurysms. Total occlusion rates of 82% were achieved at inception, 82% at 6 months, and 90% at 18 months. Satisfactory occlusion with small neck remnants was present in 17% at inception, 16% at 6 months, and 9% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Intraprocedural thromboembolic events were recorded in 3% and delayed events in 1% (all in patients taking clopidogrel). Aneurysm recurrence occurred in one patient (1%). Technical complications occurred in 5%. The total complication rate was 10%. Woven SACE is safe, efficacious, and durable at long-term 18-month follow-up, with very low recurrence and re-treatment rates. Preliminary results appear better than those for traditional laser-cut stents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting: Comparison of several anti-embolic protection devices.

    PubMed

    Taha, Mahmoud M; Maeda, Masayuki; Sakaida, Hiroshi; Kawaguchi, Kenji; Toma, Naoki; Yamamoto, Akitaka; Hirose, Tomofumi; Miura, Youichi; Fujimoto, Masashi; Matsushima, Satoshi; Taki, Waro

    2009-09-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm(3) vs. 86.9 mm(3), respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm(3)) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm(3) and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions.

  20. Aneurysm coil embolization: cost per volumetric filling analysis and strategy for cost reduction.

    PubMed

    Wang, Charlie; Ching, Esteban Cheng; Hui, Ferdinand K

    2016-05-01

    One of the primary device expenditures associated with the endovascular treatment of aneurysms is that of detachable coils. Analyzing the cost efficiency of detachable coils is difficult, given the differences in design, implantable volume, and the presence of additives. However, applying a volume per cost metric may provide an index analogous to unit price found in grocery stores. The price information for 509 different coils belonging to 31 different coil lines, available as of September 2013, was obtained through the inventory management system at the study site, and normalized to the price of the least expensive coil. Values were used to calculate the logarithmic ratio of volume over cost. Operator choice among coil sizes can vary the material costs by five-fold in a hypothetical aneurysm. The difference in coil costs as a function of cost per volume of coil can vary tremendously. Using the present pricing algorithms, using the longest available length at a particular helical dimension and system yields improved efficiency. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Fat embolism syndrome

    PubMed Central

    Richards, Robin R.

    1997-01-01

    Fat embolism syndrome, an important contributor to the development of acute respiratory distress syndrome, has been associated with both traumatic and nontraumatic disorders. Fat embolization after long bone trauma is probably common as a subclinical event. Fat emboli can deform and pass through the lungs, resulting in systemic embolization, most commonly to the brain and kidneys. The diagnosis of fat embolism syndrome is based on the patient’s history, supported by clinical signs of pulmonary, cerebral and cutaneous dysfunction and confirmed by the demonstration of arterial hypoxemia in the absence of other disorders. Treatment of fat embolism syndrome consists of general supportive measures, including splinting, maintenance of fluid and electrolyte balance and the administration of oxygen. Endotracheal intubation and mechanical ventilatory assistance can be indicated. The role of corticosteroids remains controversial. Early stabilization of long bone fractures has been shown to decrease the incidence of pulmonary complications. Clinical and experimental studies suggest that the exact method of fracture fixation plays a minor role in the development of pulmonary dysfunction. As more is learned about the specifics of the various triggers for the development of fat embolism syndrome, it is hoped that the prospect of more specific therapy for the prevention and treatment of this disorder will become a reality. PMID:9336522

  2. Treatment of type I endoleaks using transcatheter embolization with onyx.

    PubMed

    Eberhardt, Karla Maria; Sadeghi-Azandaryani, Mojtaba; Worlicek, Stefanie; Koeppel, Thomas; Reiser, Maximilian F; Treitl, Marcus

    2014-02-01

    To report a single-center experience with transcatheter embolization of type I endoleaks using the liquid embolic agent Onyx, an ethylene vinyl alcohol copolymer. Eight patients (4 men; mean age 74.8 years, range 63-86) with 10 type I endoleaks (6 abdominal and 4 thoracic) diagnosed 2 days to 9 years after endovascular repair were treated with Onyx embolization because cuff extension was precluded by an insufficient landing zone in 6 cases and an unsuitable aortic diameter in 2. Endoleaks were accessed with a 4-F diagnostic catheter and a coaxially introduced dimethylsulfoxide-compatible microcatheter. Onyx-34 was predominantly applied due to its high viscosity; patent side branches were coil embolized prior to Onyx delivery in 3 cases. Technical success of the procedure was achieved in all cases. The mean volume of Onyx used for abdominal endoleaks was 11.8 mL (range 3.0-25.5) and 19.4 mL (range 4.5-31.5) for thoracic endoleaks. The average duration of the procedure was 76.7 minutes (range 34.5-110.6), and the average radiation dose area product was 18.8 cGy*cm (2) (range 10.6-55.8). Reperfusion of the endoleak was detected in one case 2 days after the procedure. A second case showed an occluded endoleak but a small trace of contrast between the aortic wall and the stent-graft. Non-target embolization was not found in any case. Mean follow-up was 13.2 months (range 8-24). The mean reduction in diameters for thoracic aneurysms after 6 and 12 months was 0.4 and 0.9 cm, respectively, and 0.6 and 1.2 cm, respectively, for abdominal aneurysms. Transcatheter embolization of type I endoleaks using Onyx is a simple, safe, and sustainable treatment option with a high primary success rate for cases in which stent-graft extension is not possible. The benefit of additional coil embolization remains uncertain.

  3. Endovascular treatment for traumatic scalp arteriovenous fistulas: results with Onyx embolization.

    PubMed

    Dabus, Guilherme; Pizzolato, Raffaella; Lin, Eugene; Kreusch, Andreas; Linfante, Italo

    2014-06-01

    Arteriovenous fistulas of the scalp (S-AVFs) are rare lesions and may occur spontaneously or secondary to trauma. The use of Onyx for the treatment of S-AVFs is not well established at this time. We discuss three cases of traumatic S-AVFs treated successfully with Onyx embolization alone or in association with coils. The database of patients treated at the Baptist Cardiac and Vascular Institute, Miami, Florida, was reviewed. All patients with traumatic S-AVFs treated with Onyx were included. Two men and one woman with progressive enlarging pulsatile mass with bruit or tinnitus had angiographic evidence of S-AVF and were treated. In two patients the S-AVFs were secondary to hair transplantation. They were treated with Onyx-18 embolization as the single treatment modality. One patient with S-AVF resulting from temporomandibular joint arthroscopy was treated with coils and subsequent Onyx-34 embolization. In one patient, transarterial microcatheterization and injection of Onyx-18 was performed. In another patient, the intra-arterial approach was prevented by arterial vessel tortuosity. Therefore, access to the fistula was obtained through direct puncture of a large frontal vein; contrast injection confirmed the positioning of the needle within the draining vein of the AVF and Onyx-18 was then injected while the outflow vein was compressed. In the third patient in this series, coils were deployed to allow safer and more controlled injection of Onyx-34. No procedure related complications were noted. Post-embolization angiography demonstrated successful and complete occlusion of the AVF immediately after treatment. Follow-up revealed complete resolution of the symptoms. Our experience in this small series indicates that endovascular treatment of S-AVFs with Onyx is rapid, safe, and highly effective.

  4. Stent-assisted coiling of wide-neck bifurcation aneurysms with a branch incorporated in the aneurysm base: long-term follow-up in 49 patients with 53 aneurysms.

    PubMed

    Lubicz, Boris; Morais, Ricardo; Bruyère, Pierre-Julien; Ligot, Noémie; Mine, Benjamin

    2017-06-01

    Wide-neck bifurcation intracranial aneurysms (WNBA) with a branch incorporated in the aneurysm base remain difficult to treat by embolization. We aim to report our long-term follow-up of stent-assisted coiling (SAC) in this subgroup of patients. This study was approved by our local ethical committee. A retrospective review of our prospectively maintained database identified all patients treated in our institution by SAC for a WNBA with a branch incorporated in the aneurysm base. Technical issues, immediate, long-term outcomes were evaluated. Between 2007 and 2015, 49 patients with 53 intracranial aneurysms (IAs) (52 unruptured, 1 ruptured) were identified and successfully treated. No morbidity/mortality occurred. The incorporated branch was preserved in all patients but one who was treated during a vasospasm phase. At the first 6-month imaging control, the branch was patent. Immediate occlusion was near-complete in 11/53 aneurysms (20.8%), neck remnant in 20/53 aneurysms (37.7%), and incomplete in 22/53 aneurysms (41.5%). Available imaging follow-up of 47 IAs, ranging from 3 to 84 months (mean 26 months ± 19.6 months), showed 27 progressive thrombosis (57.4%), 17 stable occlusions (36.2%), 1 minor recanalization (2.1%), and 2 significant recanalizations that were retreated (4.3%). The latest imaging control showed 30 near-complete occlusions (63.8%), 13 neck remnants (27.7%), and 4 incomplete occlusions (8.5%). Stent-assisted coiling is safe and effective for the treatment of WNBA with a branch incorporated in the aneurysm base. Despite poor immediate anatomical results, long-term follow-up shows a high rate of progressive thrombosis achieving adequate and stable occlusion in most patients.

  5. Pseudoaneurysm of the Profunda Femoris Artery following Blunt Trauma Treated by Endovascular Coil Embolization: Review of Two Cases and Relevant Literature

    PubMed Central

    McNerney, Patrick; Kiproff, Paul

    2017-01-01

    Profunda femoris artery (PFA) pseudoaneurysm after blunt trauma without associated femur fracture is a rare occurrence. Most of the reported cases of PFA pseudoaneurysm in the English literature developed after penetrating trauma, surgical procedures, and femur fractures. We present two such cases following blunt trauma and without any associated long bone injury. After initial imaging failed to show any long bone fracture, CT angiography confirmed pseudoaneurysm of the branch of the PFA. Both patients were then treated with emergent coil embolization of the bleeding vessel. Pseudoaneurysms typically present late and signs of persistent hip pain, thigh swelling, presence of a pulsatile mass, and even unexplained anemia all may suggest the diagnosis. Recognition of PFA pseudoaneurysm requires high index of suspicion and is often difficult to diagnose clinically because of its location. PMID:28246563

  6. Comparison of flow diversion and coiling in large unruptured intracranial saccular aneurysms.

    PubMed

    Chalouhi, Nohra; Tjoumakaris, Stavropoula; Starke, Robert M; Gonzalez, L Fernando; Randazzo, Ciro; Hasan, David; McMahon, Jeffrey F; Singhal, Saurabh; Moukarzel, Lea A; Dumont, Aaron S; Rosenwasser, Robert; Jabbour, Pascal

    2013-08-01

    Flow diversion has emerged as an important tool for the management of intracranial aneurysms. The purpose of this study was to compare flow diversion and traditional embolization strategies in terms of safety, efficacy, and clinical outcomes in patients with unruptured, large saccular aneurysms (≥10 mm). Forty patients treated with the Pipeline Embolization Device (PED) were matched in a 1:3 fashion with 120 patients treated with coiling based on patient age and aneurysm size. Fusiform and anterior communicating artery aneurysms were eliminated from the analysis. Procedural complications, angiographic results, and clinical outcomes were analyzed and compared. There were no differences between the 2 groups in terms of patient age, sex, aneurysm size, and aneurysm location. The rate of procedure-related complications did not differ between the PED (7.5%) and the coil group (7.5%; P=1). At the latest follow-up, a significantly higher proportion of aneurysms treated with PED (86%) achieved complete obliteration compared with coiled aneurysms (41%; P<0.001). In multivariable analysis, coiling was an independent predictor of nonocclusion. Retreatment was necessary in fewer patients in the PED group (2.8%) than the coil group (37%; P<0.001). A similar proportion of patients attained a favorable outcome (modified Rankin Scale, 0-2) in the PED group (92%) and in the coil group (94%; P=0.8). The PED provides higher aneurysm occlusion rates than coiling, with no additional morbidity and similar clinical outcomes. These findings suggest that the PED might be a preferred treatment option for large unruptured saccular aneurysms.

  7. Buttock Claudication and Erectile Dysfunction After Internal Iliac Artery Embolization in Patients Prior to Endovascular Aortic Aneurysm Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rayt, H. S., E-mail: hsrayt@hotmail.com; Bown, M. J.; Lambert, K. V.

    2008-07-15

    Coil embolization of the internal iliac artery (IIA) is used to extend the application of endovascular aneurysm repair (EVAR) in cases of challenging iliac anatomy. Pelvic ischemia is a complication of the technique, but reports vary as to the rate and severity. This study reports our experience with IIA embolization and compares the results to those of other published series. The vascular unit database of the Leicester Royal Infirmary was used to identify patients who had undergone IIA coil embolization prior to EVAR. Data were collected from hospital case notes and by telephone interviews. Thirty-eight patients were identified; 29 ofmore » these were contactable by telephone. A literature search was performed for other studies of IIA embolization and the results were pooled. In this series buttock claudication occurred in 55% (16 of 29 patients) overall: in 52% of unilateral embolizations (11 of 21) and 63% of bilateral embolizations (5 of 8). New erectile dysfunction occurred in 46% (6 of 13 patients) overall: in 38% of unilateral embolizations (3 of 8) and 60% of bilateral embolizations (3 of 5). The literature review identified 18 relevant studies. The results were pooled with our results, to give 634 patients in total. Buttock claudication occurred in 28% overall (178 of 634 patients): in 31% of unilateral embolizations (99 of 322) and 35% of bilateral embolizations (34 of 98) (p = 0.46, Fisher's exact test). New erectile dysfunction occurred in 17% overall (27 of 159 patients): in 17% of unilateral embolizations (16 of 97) and 24% of bilateral embolizations (9 of 38) (p = 0.33). We conclude that buttock claudication and erectile dysfunction are frequent complications of IIA embolization and patients should be counseled accordingly.« less

  8. Embolization of traumatic and non-traumatic peripheral vascular lesions with Onyx.

    PubMed

    Regine, Renato; Palmieri, Francesco; De Siero, Michele; Rescigno, Antonio; Sica, Vincenzo; Cantarela, Raffaele; Villari, Vincenzo

    2015-03-01

    The aim of our study is to verify the feasibility and the efficacy of Onyx as embolization agent in the treatment of traumatic and non-traumatic peripheral vascular lesions. In the period between September 2006 and March 2012, we treated with Onyx 26 patients (14 males/12 females; age range, 18-85 years old; mean age, 65 years old), 11 of which with traumatic peripheral vascular lesions and 15 with non-traumatic vascular lesions (9 neoplastic hemorrhagic lesions, 3 arteriovenous malformations (AVMs) and 3 aneurysms). Follow-up controls were performed with clinical examination and by multidetector computed tomography (MDCT) imaging 1, 6, and 12 months after the procedure. All peripheral vascular lesions were embolized with Onyx; 3 patients with aneurysms were treated with Onyx associated with endovascular coils. Four elective and 22 emergency embolization procedures were performed. In all patients, we obtained cessation of bleeding and the complete and permanent embolization of all vascular lesions. Onyx is an effective and safe embolization agent for peripheral vascular lesions.

  9. Multi-mode Intravascular RF Coil for MRI-guided Interventions

    PubMed Central

    Kurpad, Krishna N.; Unal, Orhan

    2011-01-01

    Purpose To demonstrate the feasibility of using a single intravascular RF probe connected to the external MRI system via a single coaxial cable to perform active tip tracking and catheter visualization, and high SNR intravascular imaging. Materials and Methods A multi-mode intravascular RF coil was constructed on a 6F balloon catheter and interfaced to a 1.5T MRI scanner via a decoupling circuit. Bench measurements of coil impedances were followed by imaging experiments in saline and phantoms. Results The multi-mode coil behaves as an inductively-coupled transmit coil. Forward looking capability of 6mm is measured. Greater than 3-fold increase in SNR compared to conventional imaging using optimized external coil is demonstrated. Simultaneous active tip tracking and catheter visualization is demonstrated. Conclusions It is feasible to perform 1) active tip tracking, 2) catheter visualization, and 3) high SNR imaging using a single multi-mode intravascular RF coil that is connected to the external system via a single coaxial cable. PMID:21448969

  10. Computational analysis of pediatric ventricular assist device implantation to decrease cerebral particulate embolization.

    PubMed

    Nguyen, ThuyTien; Argueta-Morales, I Ricardo; Guimond, Stephen; Clark, William; Ceballos, Andres; Osorio, Ruben; Divo, Eduardo A; De Campli, William M; Kassab, Alain J

    2016-01-01

    Stroke is the most devastating complication after ventricular assist device (VAD) implantation with a 19% incidence and 65% mortality in the pediatric population. Current pediatric VAD technology and anticoagulation strategies alone are suboptimal. VAD implantation assisted by computational methods (CFD) may contribute reducing the risk of cerebral embolization. Representative three-dimensional aortic arch models of an infant and a child were generated. An 8 mm VAD outflow-graft (VAD-OG) anastomosed to the aorta was rendered and CFD was applied to study blood flow patterns. Particle tracks, originating in the VAD, were computed with a Lagrangian phase model and the percentage of particles entering the cerebral vessels was calculated. Eight implantation configurations (infant = 5 and child = 3) and 5 particle sizes (0.5, 1, 2, 3, and 4 mm) were considered. For the infant model, percentage of particles entering the cerebral vessels ranged from 15% for a VAD-OG anastomosed at 90° to the aorta, to 31% for 30° VAD-OG anastomosis (overall percentages: X(2) = 10,852, p < 0.0001). For the child model, cerebral embolization ranged from 9% for the 30° VAD-OG anastomosis to 15% for the 60° anastomosis (overall percentages: χ(2) = 10,323, p < 0.0001). Using detailed CFD calculations, we demonstrate that the risk of stroke depends significantly on the VAD implantation geometry. In turn, the risk probably depends on patient-specific anatomy. CFD can be used to optimize VAD implantation geometry to minimize stroke risk.

  11. Embolization of a Hemorrhoid Following 18 Hours of Life-Threatening Bleeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berczi, Viktor, E-mail: berczi@hotmail.com; Gopalan, Deepa; Cleveland, Trevor J

    2008-01-15

    Hemorrhoids usually do not pose diagnostic difficulties and they rarely cause massive bleeding. We report a case of massive rectal bleeding over 18 h needing 22 U blood transfusion treated by superselective transcatheter coil embolization 12 h following operative treatment performed in a different hospital. Diagnostic angiography with a view to superselective embolization, following failure of sigmoidoscopy to localize and treat the cause of hemorrhage, might act as a life-saving treatment in massive rectal bleeding, obviating the need for repeated endoscopy or emergency surgery.

  12. Multimode intravascular RF coil for MRI-guided interventions.

    PubMed

    Kurpad, Krishna N; Unal, Orhan

    2011-04-01

    To demonstrate the feasibility of using a single intravascular radiofrequency (RF) probe connected to the external magnetic resonance imaging (MRI) system via a single coaxial cable to perform active tip tracking and catheter visualization and high signal-to-noise ratio (SNR) intravascular imaging. A multimode intravascular RF coil was constructed on a 6F balloon catheter and interfaced to a 1.5T MRI scanner via a decoupling circuit. Bench measurements of coil impedances were followed by imaging experiments in saline and phantoms. The multimode coil behaves as an inductively coupled transmit coil. The forward-looking capability of 6 mm was measured. A greater than 3-fold increase in SNR compared to conventional imaging using optimized external coil was demonstrated. Simultaneous active tip tracking and catheter visualization was demonstrated. It is feasible to perform 1) active tip tracking, 2) catheter visualization, and 3) high SNR imaging using a single multimode intravascular RF coil that is connected to the external system via a single coaxial cable. Copyright © 2011 Wiley-Liss, Inc.

  13. Balloon-occluded Retrograde Transvenous Obliteration (BRTO): Technique and Intraprocedural Imaging

    PubMed Central

    Sabri, Saher S.; Saad, Wael E. A.

    2011-01-01

    Balloon-occluded retrograde transvenous obliteration (BRTO) is an endovascular technique used as a therapeutic adjunct or alternative to transjugular intrahepatic shunts (TIPS) in the management of gastric varices. Occlusion balloons are strategically placed to modulate flow within the gastrorenal or gastrocaval shunt to allow stagnation of the sclerosant material within the gastric varix. The approach and complexity of the procedure depends on the anatomic classification of inflow and outflow veins of the varix. Ethanolamine oleate has been described as the main sclerosant used in this procedure. Recently, foam sclerosants have gained popularity as alternative embolization agents, which provide the advantage of better variceal wall contact and potentially less dose of sclerosant. PMID:22942548

  14. Disastrous Portal Vein Embolization Turned into a Successful Intervention

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dobrocky, Tomas, E-mail: tomas.dobrocky@insel.ch; Kettenbach, Joachim, E-mail: joachim.kettenbach@stpoelten.lknoe.at; Lopez-Benitez, Ruben, E-mail: Ruben.lopez@insel.ch

    Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloonmore » catheter, inflating the balloon, and pulling the plug into the main right portal vein.« less

  15. Systemic Embolic Complications of Pulmonary Vein Angioplasty in Children.

    PubMed

    Esch, Jesse J; Porras, Diego; Bergersen, Lisa; Jenkins, Kathy J; Marshall, Audrey C

    2015-10-01

    Pulmonary vein stenosis (PVS) carries significant morbidity and mortality for affected children, and its management often requires multiple angioplasty procedures. PVS angioplasty can be complicated by systemic embolic events such as stroke, but incidence and risk factors are poorly understood. We reviewed pediatric catheterizations involving PVS angioplasty and/or stent placement performed at Boston Children's Hospital between July 2005 and February 2014. A total of 406 cases were performed in 144 distinct patients. Patients underwent a median of two catheterizations, at median age 1 year and weight 6.9 kg. Eleven (2.7 %) catheterizations were complicated by clinically apparent systemic embolic events, comprising 10 strokes (one with associated hepatic embolism) and 1 renal infarct. Prevalence of clinically evident stroke among this cohort was 7.6 %. Using a prior (uncomplicated) catheterization to allow each patient to serve as their own control, we sought to identify potentially modifiable risk factors for systemic embolic events. Although this analysis was limited by low power, complicated and uncomplicated angioplasties did not appear to differ in case time, contrast dose, anticoagulation management, use of cutting balloons, number of catheter exchanges, or size of long sheath used. Significant non-embolic adverse events were common, occurring in 25 % of catheterizations. Systemic embolism appears to complicate PVS angioplasty at a rate much higher than that described for other congenital catheterizations. This risk may be inherent to the procedure rather than related to any modifiable or operator-dependent factors.

  16. [Endovascular treatment of carotid-cavernous fistula type A with platinium coils].

    PubMed

    Culafić, Slobodan; Juszkat, Robert; Rusović, Sinisa; Stefanović, Dara; Minić, Ljubodrag; Spaić, Milan

    2008-12-01

    Carotid-cavernous fistulas are abnormal communications between carotid arteries or their branches and the cavernous system caused mostly by trauma. Posttraumatic fistulas represent 70% of all carotid-cavernous fistulas and they are mostly high-flow shunts (type A). This type gives characteristic eye symptoms. This paper presents a 44-year old male patient with carotid-cavernous fistula as a result of penetrating head injury. In clinical presentation the patient had exophthalmos, conjunctival chemosis and weakening of vision on the right eye, headache and diplopia. Digital subtracted angiography showed high-flow carotid-cavernous fistula, which was vascularised from the left carotid artery and from vertebrobasilar artery. Endovascular embolization with platinum coils was performed through the transarterial route (endoarterial approach). Check angiogram confirmed that the fistula was closed and that no new communications developed. Embolization of complex carotid-cavernous fistula type A was successfully performed with platinum coils by endovascular approach.

  17. Outcomes of cellophane banding or percutaneous transvenous coil embolization of canine intrahepatic portosystemic shunts.

    PubMed

    Case, J Brad; Marvel, Sarah J; Stiles, Mandy C; Maisenbacher, Herb W; Toskich, Beau B; Smeak, Dan D; Monnet, Eric L

    2018-06-01

    To compare clinical outcomes of dogs with congenital intrahepatic portosystemic shunts (CIHPSS) treated with cellophane banding (CB) or percutaneous transvenous coil embolization (PTCE). Dual-institutional retrospective study. Fifty-eight dogs with CIHPSS (2001-2016). Medical records of dogs undergoing CB or PTCE for CIHPSS were reviewed for signalment, body weight, hematologic values, shunt location, attenuation technique, procedure time, duration of hospitalization, complications, date of follow-up, and cause of death if applicable. Thirty-one dogs underwent CB, and 27 dogs underwent PTCE. No differences were detected between groups for gender, preoperative packed cell volume, albumin, cholesterol, or bile acids. Body weight was greater in dogs treated via PTCE. Shunts differed in location because dogs undergoing CB were diagnosed with more left divisional shunts compared with PTCE dogs. Procedural duration of CB and PTCE did not differ. Dogs treated with CB sustained more minor postoperative complications and were hospitalized longer than dogs treated with PTCE. The 1-year and 2-year survival rates were 89% for the CB group and 87% and 80% for the PTCE group, respectively. The proportion surviving at 5 years was 75% and 80% for CB dogs and PTCE dogs, respectively. CB and PTCE are associated with similar short-term and intermediate-term survival. PTCE is a minimally invasive alternative to CB via celiotomy. However, CB allows concurrent abdominal procedures requiring the same approach. © 2017 The American College of Veterinary Surgeons.

  18. Recanalization of Splenic Artery Aneurysm After Transcatheter Arterial Embolization Using N-Butyl Cyanoacrylate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsumoto, Keiji; Ushijima, Yasuhiro, E-mail: ushijima@radiol.med.kyushu-u.ac.jp; Tajima, Tsuyoshi

    2010-02-15

    A 65-year-old woman who had been diagnosed as having microscopic polyangiitis developed sudden abdominal pain and entered a state of shock. Abdominal CT showed massive hemoperitoneum, and emergent angiography revealed a ruptured splenic artery aneurysm. After direct catheterization attempts failed due to tortuous vessels and angiospasm, transcatheter arterial embolization using an n-butyl cyanoacrylate (NBCA)-lipiodol mixture was successfully performed. Fifty days later, the patient developed sudden abdominal pain again. Repeated angiography demonstrated recanalization of the splenic artery and splenic artery aneurysm. This time, the recanalized aneurysm was embolized using metallic coils with the isolation method. Physicians should keep in mind thatmore » recanalization can occur after transcatheter arterial embolization using N-butyl cyanoacrylate, which has been used as a permanent embolic agent.« less

  19. Medina® Embolization Device for the Treatment of Intracranial Aneurysms: Safety and Angiographic Effectiveness at 6 Months.

    PubMed

    Sourour, Nader-Antoine; Vande Perre, Saskia; Maria, Federico Di; Papagiannaki, Chrysanthi; Gabrieli, Joseph; Pistocchi, Silvia; Bartolini, Bruno; Degos, Vincent; Carpentier, Alexandre; Chiras, Jacques; Clarençon, Frédéric

    2018-02-01

    The Medina Embolization Device (MED) is a new concept device that combines the design of a detachable coil and the one of an intrasaccular flow disruption device. To evaluate the feasibility, safety, and 6- to 9-mo effectiveness of this new device for the treatment of intracranial wide-necked aneurysms. Twelve patients (10 females, mean age = 56 yr) with 13 wide-necked intracranial aneurysms (3 ruptured; 10 unruptured) were treated by means of the MED from January 2015 to October 2015. In 15% of the cases, MEDs were used in a standalone fashion; in 85% of the cases, additional regular coils were used. Adjunctive compliant balloon was used in 4 of 13 cases (31%). Procedure-related complications were systematically recorded; discharge and 6- to 9-mo follow-up modified Rankin Scale was assessed. Angiographic follow-up was performed with a mean delay of 5.5 ± 1.7 mo. Occlusion rate was evaluated in postprocedure and at midterm follow-up using the Roy-Raymond scale. The deployment of the MED was feasible in all cases. No perforation was recorded. One case of thromboembolic complication was observed in a ruptured anterior communicating artery aneurysm, without any clinical consequence at follow-up. Grade A occlusion rate was 61.5% in postprocedure and 83% at 6-mo follow-up. Two cases (17%) of recanalization were documented angiographically. The MED is a new generation device combining the design of a detachable coil and an intrasaccular flow disruption device. According to our early experience, this device is safe and provides a satisfactory occlusion rate at angiographic follow-up of 6 mo. Copyright © 2017 by the Congress of Neurological Surgeons

  20. Embolization of traumatic and non-traumatic peripheral vascular lesions with Onyx

    PubMed Central

    Regine, Renato; De Siero, Michele; Rescigno, Antonio; Sica, Vincenzo; Cantarela, Raffaele; Villari, Vincenzo

    2015-01-01

    Purpose The aim of our study is to verify the feasibility and the efficacy of Onyx as embolization agent in the treatment of traumatic and non-traumatic peripheral vascular lesions. Materials and Methods In the period between September 2006 and March 2012, we treated with Onyx 26 patients (14 males/12 females; age range, 18–85 years old; mean age, 65 years old), 11 of which with traumatic peripheral vascular lesions and 15 with non-traumatic vascular lesions (9 neoplastic hemorrhagic lesions, 3 arteriovenous malformations (AVMs) and 3 aneurysms). Follow-up controls were performed with clinical examination and by multidetector computed tomography (MDCT) imaging 1, 6, and 12 months after the procedure. Results All peripheral vascular lesions were embolized with Onyx; 3 patients with aneurysms were treated with Onyx associated with endovascular coils. Four elective and 22 emergency embolization procedures were performed. In all patients, we obtained cessation of bleeding and the complete and permanent embolization of all vascular lesions. Conclusions Onyx is an effective and safe embolization agent for peripheral vascular lesions. PMID:25838923

  1. Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome: Midterm outcomes and aortic remodeling.

    PubMed

    Faure, Elsa Madeleine; El Batti, Salma; Abou Rjeili, Marwan; Ben Abdallah, Iannis; Julia, Pierre; Alsac, Jean-Marc

    2018-05-17

    The study objective was to assess the midterm outcomes and aortic remodeling in patients with Marfan syndrome with complicated acute type B aortic dissection treated with stent-assisted, balloon-induced intimal disruption and relamination. We reviewed all patients treated with stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection associated with Marfan syndrome according to the revised Ghent criteria. Between 2015 and November 2017, 7 patients with Marfan syndrome underwent stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection. The median age of patients was 47 years (range, 23-70). Four patients had a history of aortic root replacement. Technical success was achieved in 100%. Three patients required an adjunctive procedure for renal artery stenting (n = 2) and iliac artery stenting (n = 1). There was no in-hospital death, 30-day postoperative stroke, spinal cord ischemia, ischemic colitis, or renal failure requiring dialysis. At a median follow-up of 15 months (range, 7-28), 1 patient required aortic arch replacement for aneurysmal degeneration associated with a type Ia endoleak at 2 years, giving a late reintervention rate of 14%. There was no other secondary endoleak. The primary visceral patency rate was 100%. There were no all-cause deaths reported. At last computed tomography scan, all patients had complete aortic remodeling of the treated thoracoabdominal aorta. Distally, at the nonstented infrarenal aortoiliac level, 6 patients had persistent false lumen flow with stable aorto-iliac diameter in 5. One patient had iliac diameter growth (27 mm diameter at last computed tomography scan). Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome is feasible, safe, and associated with an immediate and midterm persisting thoracoabdominal aortic remodeling. Copyright

  2. Preoperative spinal tumor embolization: an institutional experience with Onyx.

    PubMed

    Ghobrial, George M; Chalouhi, Nohra; Harrop, James; Dalyai, Richard T; Tjoumakaris, Stavropoula; Gonzalez, L Fernando; Hasan, David; Rosenwasser, Robert H; Jabbour, Pascal

    2013-12-01

    Preoperative embolization has the potential to decrease intraoperative blood loss and facilitate spinal cord decompression and tumor resection. We report our institutional experience with the embolization of hypervascular extradural spinal tumors with Onyx as well as earlier embolic agents in a series of 28 patients. A retrospective case review was conducted on patients undergoing preoperative transarterial embolization of a spinal tumor between 1995 and 2012 at our institution. Twenty-eight patients met the inclusion criteria, with a mean age of 60.6 years. Twenty-eight patients had metastatic tumors. In 14 (50%) patients the metastases were from renal cell carcinomas. Fifty-four vessels were embolized using PVA, NBCA, Onyx, coils, or embospheres. Sixteen patients were treated with Onyx, 6 patients with PVA, 3 patients with embospheres, 2 patients with NBCA, and 3 patients with a combination of embolic agents. The average decrease in tumor blush was 97.8% with Onyx versus 92.7% with the rest of the embolic agents (p=0.08). The estimated blood loss was 1616ml (range 350-5000ml). Blood loss was 750cm(3) on average with Onyx versus 1844 with the rest of the embolic agents (p=0.14). The mean length of stay was 16 days. The mortality rate was zero. Pre- and post-operative modified Rankin Score (mRS) did not differ significantly in the series (3.12 versus 3.10, respectively, p=0.9). In our experience, the use of transarterial tumor embolization as an adjunct for spinal surgery is a safe and feasible option. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Prevention of Retrograde Blood Flow Into Large or Giant Internal Carotid Artery Aneurysms by Endovascular Coil Embolization with High-Flow Bypass: Surgical Technique and Long-Term Results.

    PubMed

    Nakajima, Norio; Nagahiro, Shinji; Satomi, Junichiro; Tada, Yoshiteru; Nakajima, Kohei; Sogabe, Shu; Hanaoka, Mami; Matsubara, Shunji; Uno, Masaaki; Satoh, Koichi

    2015-06-01

    Recanalization has been reported in large or giant aneurysms of the internal carotid artery (ICA) addressed by high-flow bypass and endovascular treatment. Aneurysmal recanalization may be attributable to retrograde blood flow into the aneurysm through the ICA branches, such as the ophthalmic artery or the meningohypophyseal trunk, or through the surgically created bypass. We modified the endovascular treatment of aneurysms to prevent retrograde flow and evaluated the long-term efficacy of our method. We used a hybrid operative/endovascular technique to treat 5 patients with large or giant aneurysms arising from the C2-C4 segment of the ICA who presented with visual symptoms due to the mass effect of the aneurysm. To prevent retrograde flow into the aneurysm our modified endovascular treatment involves coil embolization of the aneurysmal orifice and the ICA, including the origin of the ophthalmic artery and meningohypophyseal trunk, and placement of a high-flow bypass using a radial artery graft. During the 5- to 12-year follow-up period, 4 aneurysms disappeared, and the other decreased in size. There were no subarachnoid hemorrhages. All bypass grafts remained patent. Visual preservation was achieved in 2 patients; 1 patient manifested visual improvement. Although 2 patients experienced transient neurological deficits we encountered no permanent complications in this series. The final modified Rankin scale of the 5 patients was 0 or 1. Prevention of retrograde flow into the aneurysm by coil embolization with high-flow bypass is a safe and effective method. It prevents the recanalization of large or giant ICA aneurysms. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Orbital venous malformation: percutaneous treatment using an electrolytically detachable fibred coil.

    PubMed

    Diolaiuti, Sara; Iizuka, Tateyuki; Schroth, Gerhard; Remonda, Luca; Laedrach, Kurt; El-Koussy, Marwan; Frueh, Beatrice E; Goldblum, David

    2009-03-01

    To report the efficacy of percutaneous treatment of an orbital venous malformation with an electrolytically detachable fibred coil. We report an instance of radiography-guided percutaneous treatment with an electrolytically detachable fibred coil in a 16-year-old boy with acute, spontaneous, painless proptosis on the left side, which progressed with time. Magnetic resonance imaging, angiography and orbitophlebography revealed a low-flow, intraorbital venous malformation. Percutaneous puncture and drainage were followed by a short remission. Following an acute recurrence, a single detachable fibred coil was deployed via a percutaneous approach under angiographic guidance. No radiological or clinical recurrences were observed over 4 years. Embolization of a deep orbital venous malformation with detachable fibred coils via a percutaneous approach can be highly effective, and may be considered before proceeding with open surgery.

  5. Value of Round Ligament Artery Embolization in the Management of Postpartum Hemorrhage.

    PubMed

    Leleup, Grégoire; Fohlen, Audrey; Dohan, Anthony; Bryan-Rest, Lara; Le Pennec, Vincent; Limot, Olivier; Le Dref, Olivier; Soyer, Philippe; Pelage, Jean-Pierre

    2017-05-01

    To evaluate the feasibility and efficacy of embolization of the round ligament arteries in the management of postpartum hemorrhage. Eleven women (mean age, 31 y) underwent round ligament artery because of persistent or recurrent hemorrhage after initial uterine or internal iliac artery embolization. A total of 16 round ligament arteries were embolized. The round ligament artery arose from the inferior epigastric artery in 11 cases (69%) and directly from the external iliac artery in 5 (31%). Embolization was performed with calibrated microspheres in 7 women (63%) and gelatin sponge pledgets in 4 (37%). Coils were used in addition to gelatin sponge pledgets in 3 patients. Hemostasis was achieved in 10 patients (91%), and 1 required additional conservative surgery. The mean hemoglobin level before embolization was 7.2 g/dL ± 1 and increased significantly on day 1 after embolization (10.3 g/dL ± 1.0; P < .05). No procedure-related complication was reported. The mean hospital stay was 5.6 days ± 2. Two patients had further pregnancies 13 and 14 months after embolization. Selective embolization of the round ligament artery is a safe and effective treatment for obstetric hemorrhage. It should be considered in cases of persistent or recurrent bleeding after initial uterine or internal iliac artery embolization. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  6. International survey on neuroradiological interventional and therapeutic devices and materials.

    PubMed

    van den Berg, René; Mayer, Thomas E

    2015-12-01

    A web-based survey was performed among the members of the World Federation of Interventional and Therapeutic Neuroradiology to determine the differences in availability, pricing, and performance of endovascular devices with special focus on coils, intra-arterial stroke devices, detachable balloons, and liquid embolic materials. The results of this survey show that the quality of the majority of interventional neuroradiology devices is good and compatibility issues are limited. Individual action towards suppliers is recommended to discuss the availability and pricing of devices and embolization materials. © The Author(s) 2015.

  7. Embolization of Isolated Lumbar Artery Injuries in Trauma Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sofocleous, Constantinos T., E-mail: constant@pol.net; Hinrichs, Clay R.; Hubbi, Basil

    Purpose. The purpose of the study was to evaluate the angiographic findings and results of embolotherapy in the management of lumbar artery trauma. Methods. All patients with lumbar artery injury who underwent angiography and percutaneous embolization in a state trauma center within a 10-year period were retrospectively reviewed. Radiological information and procedural reports were reviewed to assess immediate angiographic findings and embolization results. Long-term clinical outcome was obtained by communication with the trauma physicians as well as with chart review. Results. In a 10-year period, 255 trauma patients underwent abdominal aortography. Eleven of these patients (three women and eight men)more » suffered a lumbar artery injury. Angiography demonstrated active extravasation (in nine) and/or pseudoaneurysm (in four). Successful selective embolization of abnormal vessel(s) was performed in all patients. Coils were used in six patients, particles in one and gelfoam in five patients. Complications included one retroperitoneal abscess, which was treated successfully. One patient returned for embolization of an adjacent lumbar artery due to late pseudoaneurysm formation. Conclusions. In hemodynamically stable patients, selective embolization is a safe and effective method for immediate control of active extravasation, as well as to prevent future hemorrhage from an injured lumbar artery.« less

  8. Spontaneous delayed migration/shortening of the pipeline embolization device: report of 5 cases.

    PubMed

    Chalouhi, N; Tjoumakaris, S I; Gonzalez, L F; Hasan, D; Pema, P J; Gould, G; Rosenwasser, R H; Jabbour, P M

    2013-12-01

    Five patients were found to have spontaneous delayed migration/shortening of their Pipeline Embolization Devices on follow-up angiography. The device migrated proximally in 4 patients and distally in 1 patient. One patient had a subarachnoid hemorrhage and died as a result of migration of the Pipeline Embolization Device, and another patient presented with complete MCA occlusion and was left severely disabled. Mismatch in arterial diameter between inflow and outflow vessels was a constant finding. Migration of the Pipeline Embolization Device was managed conservatively, with additional placement of the device, or with parent vessel occlusion. Obtaining complete expansion of the embolization device by using a longer device, increasing vessel coverage, using adjunctive aneurysm coiling, and avoiding dragging and stretching of the device are important preventive measures. Neurointerventionalists should be aware of this potentially fatal complication and take all necessary preventive measures.

  9. Onyx removal after embolization of a superior sagittal sinus dural arteriovenous fistula involving scalp artery.

    PubMed

    Watanabe, Jun; Maruya, Jun; Nishimaki, Keiichi; Ito, Yasushi

    2016-01-01

    Most dural arteriovenous fistula (DAVF) in superior sagittal sinus (SSS) requires multimodal treatment. Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. A 59-year-old male presented with involuntary movements of both legs and progressive dementia. Cerebral angiography demonstrated the DAVF in the SSS fed by bilateral superficial temporal, occipital, and middle meningeal arteries. The posterior SSS was thrombosed, and the main drainers were cortical veins. Combined treatment with transarterial embolization using Onyx and transvenous embolization using coils was performed. Although symptoms were improved, a small DAVF remained. Two months later, Onyx cast extrusion through the scalp was observed, requiring removal and debridement because of infection at the extrusion sites. Surgery for the residual DAVF would be difficult because of scalp condition; therefore, an additional endovascular treatment was conducted, completely occluding DAVF. Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. Therefore, scalp infection should be considered because it may preclude additional surgical procedures.

  10. Arteriography after embolization before distal pancreatectomy with en bloc celiac axis resection.

    PubMed

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Murakami, Yoshiaki; Uemura, Kenichiro; Awai, Kazuo

    2015-01-01

    To evaluate hemodynamics by arteriographic examinations with and without CT in the stomach wall and liver after preoperative embolization to redistribute blood flow to the stomach and liver, which is unified to be supplied from the superior mesenteric artery, before distal pancreatectomy with en bloc celiac axis resection (DP-CAR). In six patients with locally advanced cancer of the pancreatic body in whom DP-CAR was planned, the left gastric artery and common hepatic artery were embolized with coils. Celiac arteriography and superior mesenteric arteriography with and without CT were performed after embolization. In all six patients, intrahepatic arteries and the left gastric artery were not visualized on celiac arteriography. On both superior mesenteric arteriography and CT obtained while contrast medium was infused via the superior mesenteric artery and which was performed immediately after embolization procedures, the right gastric artery, gastroepiploic artery, gastroduodenal artery, and all hepatic arterial branches were clearly detected. Also the distal part of the left gastric artery close to the embolized point was detected with at least one of the imaging modalities. It was clarified radiologically that preoperative embolization results in increased blood supply to the stomach wall and liver through the pancreatic arcade.

  11. Short- and long-term results of transcatheter embolization for massive arterial hemorrhage from gastroduodenal ulcers not controlled by endoscopic hemostasis

    PubMed Central

    Loffroy, Romaric; Guiu, Boris; Mezzetta, Lise; Minello, Anne; Michiels, Christophe; Jouve, Jean-Louis; Cheynel, Nicolas; Rat, Patrick; Cercueil, Jean-Pierre; Krausé, Denis

    2009-01-01

    BACKGROUND AND AIM: Severe bleeding from gastrointestinal ulcers is a life-threatening event that is difficult to manage when endoscopic treatment fails. Transcatheter embolization has been suggested as an alternative treatment in this situation. The present study reports on the efficacy and long-term outcomes of transcatheter embolization after failed endoscopic treatments were assessed in high-operative-risk patients. METHODS: A retrospective review of 60 consecutive emergency embolization procedures in hemodynamically unstable patients (41 men, 19 women; mean [±SD] age 69.4±15 years) was conducted. Patients were referred for selective angiography between 1999 and 2008 after failed endoscopic treatment of massive bleeding from gastrointestinal ulcers. Mean follow-up was 22 months. RESULTS: Embolization was feasible and successful in 57 patients. Sandwich coiling of the gastroduodenal artery was used in 34 patients, and superselective occlusion of the terminal feeding artery (with glue, coils or gelatin particles) was used in 23 patients. Early rebleeding occurred in 16 patients and was managed with endoscopy (n=8), reembolization (n=3) or surgery (n=5). No major embolization-related complications occurred. Sixteen patients died within 30 days after embolization (including three who died from rebleeding) and 11 died thereafter. No late bleeding recurrences were reported. CONCLUSIONS: Selective angiographic embolization is safe and effective for controlling life-threatening bleeding from gastroduodenal ulcers. The procedure usually obviates the need for emergency surgery in these high-risk patients. Survival depends chiefly on underlying conditions. PMID:19214287

  12. [Tentorial Dural Arteriovenous Fistula Successfully Treated with Transvenous Embolization Using a Double Catheterization Technique through Venous Drainage:A Case Report].

    PubMed

    Yamakawa, Akira; Fujita, Atsushi; Tanaka, Hirotomo; Ikeda, Mitsuru; Morikawa, Masashi; Kohmura, Eiji

    2017-07-01

    Tentorial dural arteriovenous fistulas(dAVFs)are a rare clinical entity accounting for less than 10% of all intracranial dAVFs. Because these lesions are characterized by high hemorrhagic risk, aggressive treatment should be considered. Although the number of reported cases treated with endovascular transarterial embolization(TAE)using glue has been increasing, little is known about the transvenous approach. Here, we report the case of a patient with a tentorial dAVF who was successfully treated with transvenous embolization(TVE)through venous drainage using a double catheterization technique. A 68-year-old male patient who had a history of left putaminal hemorrhage treated with a craniotomy was diagnosed with a tentorial dAVF on a magnetic resonance angiogram. Because the patient refused another craniotomy for surgical interruption of the dAVF, an endovascular approach was considered. We first attempted to perform TAE with glue, but catheterization into the tortuous meningohypophyseal trunk failed. We then performed a TVE of the venous drainage near the shunt with detachable coils and achieved complete obliteration of the fistula. During coil embolization of the venous drainage, insertion of small coils near the shunt was supported by another anchor coil that was delivered using a double catheterization technique. The method of TVE through venous drainage using a double catheterization technique, which involved placing coils in the fragile drainage vein, was safe and effective in a case of tentorial dAVF. This technique should be considered as another option for the management of complex tentorial dAVFs.

  13. Emborrhoid: A New Concept for the Treatment of Hemorrhoids with Arterial Embolization: The First 14 Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vidal, V., E-mail: vincent.vidal@ap-hm.fr; Sapoval, M., E-mail: marc.sapoval@gmail.com; Sielezneff, Y., E-mail: igor.sielezneff@ap-hm.fr

    2015-02-15

    PurposeThe ‘emborrhoid’ technique consists of the embolization of the hemorrhoidal arteries. The endovascular arterial occlusion is performed using coils placed in the terminal branches of the superior rectal arteries. The emborrhoid technique has been modeled after elective transanal Doppler-guided hemorrhoidal artery ligation which has been shown to be effective in hemorrhoidal disease. We report the first 14 cases of our experience with emborrhoid technique.Materials and MethodsFourteen patients with disabling chronic rectal bleeding were treated using the emborrhoid technique (3 women, 11 men). The stage of the hemorrhoidal disease was II (10 patients), III (3), and IV (1). This treatment wasmore » decided by a multidisciplinary team (proctologist, visceral surgeon, and radiologist). Seven patients underwent previous proctological surgery. Ten patients had coagulation disorders (anticoagulants or cirrhosis). Superior rectal arteries were embolized with pushable microcoils (0.018).ResultsTechnical success of the embolization procedure was 100 %. Clinical success at 1 month was 72 % (10/14). Of the 4 patients who experienced rebleeding, two underwent additional embolization of the posterior rectal arteries with success. No pain or ischemic complications were observed in 13 patients. One patient experienced a temporary painful and edematous, perianal reaction.ConclusionOur case studies suggest that coil embolization of the superior rectal arteries is technically feasible, safe and well tolerated. Additional studies are needed to evaluate the efficacy of this new ‘emborrhoid’ technique in the management of hemorrhoidal disease.« less

  14. Immediate Outcome of Balloon Mitral Valvuloplasty with JOMIVA Balloon during Pregnancy

    PubMed Central

    Ramasamy, Ramona; Kaliappan, Tamilarasu; Gopalan, Rajendiran; Palanimuthu, Ramasmy; Anandhan, Premkrishna

    2017-01-01

    with JOMIVA balloon. Post procedure mean mitral valve area was 1.7 cm2 as assessed by echocardiography. Post procedure mean gradient across the mitral valve as assessed by echocardiography was 5 mmHg. Two patients had moderate to severe mitral regurgitation after the procedure and the rest had either no mitral regurgitation or mild mitral regurgitation after the procedure. None of the patients warranted mitral valve replacement after BMV. No patients had any manifestations of systemic embolism like cerebrovascular accident or limb ischemia after the procedure. None of the patients had preterm delivery or adverse fetal outcome during index hospitalisation. Conclusion Over the wire BMV is safe and effective method during pregnancy. The results are comparable to that of Inoue technique. BMV offers a good symptomatic improvement in pregnant women presenting with symptoms of pulmonary congestion because of Rheumatic mitral stenosis. PMID:28384909

  15. Percutaneous Antegrade Varicocele Embolization Via the Testicular Vein in a Patient with Recurrent Varicocele After Surgical Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guevara, Carlos J., E-mail: guevarac@mir.wustl.edu; El-Hilal, Alexander H., E-mail: elhilala@mir.wustl.edu; Darcy, Michael D., E-mail: darcym@mir.wustl.edu

    This is a case report of an adolescent male who underwent surgical ligation for a left-sided varicocele that recurred 2 years later. Standard retrograde embolization via the left renal vein was not possible, because there was no connection from the renal vein to the gonadal vein following surgical ligation. The patient was treated via antegrade access of the spermatic vein at the inguinal level with subsequent coil embolization.

  16. Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients.

    PubMed

    Sedat, Jacques; Chau, Yves; Gaudart, Jean; Sachet, Marina; Beuil, Stephanie; Lonjon, Michel

    2018-02-01

    Coiling associated with placement of a self-expandable intracranial stent has improved the treatment of intracranial wide-necked aneurysms. Little is known, however, about the durability of this treatment. The purpose of this report is to present our experience with the LEO stent and to evaluate the complications, effectiveness, and long-term results of this technique. We analyzed the records of 155 intracranial unruptured aneurysms that were treated by stent-assisted coiling with a LEO stent between 2008 and 2012. Procedural, early post-procedural, and delayed complications were recorded. Clinical and angiographic follow-up of patients was conducted over a period of at least 36 months. No procedural mortality was observed. One-month morbidity was observed in 14 out of 153 patients (9,15%). One hundred thirty-eight patients (with 140 aneurysms) had clinical and angiographic follow-up for more than 36 months. No aneurysm rupture was observed during follow-up. Four patients presented an intra-stent stenosis at 8 months, and 6 patients who had an early recurrence were retreated. Final results showed 85% complete occlusion, 13% neck remnants, and 2% stable incomplete occlusion. Stent-assisted coiling with the LEO stent is a safe and effective treatment for unruptured intracranial aneurysms. The long-term clinical outcomes with the LEO stent are excellent with a high rate of complete occlusion that is stable over time.

  17. ONYX versus n-BCA for embolization of cranial dural arteriovenous fistulas.

    PubMed

    Rabinov, James David; Yoo, Albert J; Ogilvy, Christopher S; Carter, Bob S; Hirsch, Joshua A

    2013-07-01

    To evaluate the efficacy of n-butyl-2-cyanoacrylate (Trufill n-BCA) versus ethylene vinyl alcohol copolymer (ONYX) for the embolization of cranial dural arteriovenous fistulas (DAVF). Fifty-three consecutive patients with cranial dural AVF were treated with liquid embolic agents from November, 2003 to November, 2008. These 53 patients had 56 lesions treated with arterial embolization. Patients embolized to completion underwent follow-up angiography at 3 months to assess for durable occlusion. Twenty-one lesions were treated with n-BCA. Seven patients treated with n-BCA had initial angiographic occlusion of their DAVF, which were durable at 3 months. Six patients had adjunctive treatment with coils and/or polyvinyl alcohol particles, but none of these were occluded by endovascular treatment alone. Eleven patients underwent post-embolization surgery for closure of their DAVF. There was one death related to intractable status epilepticus at presentation. One patient developed a major stroke from venous sinus thrombosis after embolization. Thirty-five lesions were treated with ONYX in 34 patients. Twenty-nine patients treated with ONYX had initial angiographic occlusion of their DAVF by embolization alone. One patient had recurrence at 3 months and was re-treated out of 27 total follow-ups. Four patients underwent post-embolization surgical obliteration of their lesions. No deaths or major strokes occurred in this cohort. Initial angiographic occlusion (p=0.0004) and durable angiographic occlusion (p=0.0018) rates for embolization of cranial DAVF show a statistically significant higher efficacy with ONYX compared with n-BCA. Patients embolized with ONYX underwent surgery less frequently compared with those treated with n-BCA (p=0.0015).

  18. Emergency transcatheter arterial embolization for massive gastrointestinal arterial hemorrhage.

    PubMed

    Shi, Zhong Xing; Yang, Jing; Liang, Hong Wei; Cai, Zhen Hua; Bai, Bin

    2017-12-01

    To evaluate the different arteriographic manifestations of acute arterial massive hemorrhage of the gastrointestinal (GI) tract and the efficacy of emergency transcatheter arterial embolization (ETAE).A total of 88 patients with acute massive GI bleeding who experienced failure of initial endoscopy and/or conservative treatment were referred to our interventional department for acute GI arteriography from January 2007 to June 2015. After locating the source of bleeding, appropriate embolic agents, such as spring coil, hydroxyl methyl acrylic acid gelatin microspheres, polyvinyl alcohol (PVA) particles, etc., were used to embolize the targeted vessels. The angiographic manifestations and the effects of embolization of acute arterial massive hemorrhage of the GI tract were retrospectively analyzed.Of the 88 patients, 54 were diagnosed with arterial hemorrhage of the upper GI tract and 34 with arterial hemorrhage of the lower GI tract. Eighty cases were associated with positive angiography, which showed the following: contrast extravasation (only); gastroduodenal artery stenosis; pseudoaneurysm (only); pseudoaneurysm rupture with contrast extravasation; pseudoaneurysms merged with intestinal artery stenosis; GI angiodysplasia; and tumor vascular bleeding. Eight cases were diagnosed with negative angiography. Seven-two patients underwent successful hemostasis, and a total of 81 arteries were embolized. The technical and clinical success rates (no rebleeding within 30 days) in performing transcatheter embolization on patients with active bleeding were 100% and 84.71%, respectively (72 of 85). Within 30 days, the postoperative rebleeding rate was 15.29% (13/85). Of these rebleeding cases, 2 patients were formerly treated with "blind embolization," 7 underwent interventional embolic retreatment, and 3 had surgical operations. All cases were followed-up for 1 month, and 3 patients died from multiple organ failure. No serious complications such as bowel ischemia necrosis

  19. Onyx removal after embolization of a superior sagittal sinus dural arteriovenous fistula involving scalp artery

    PubMed Central

    Watanabe, Jun; Maruya, Jun; Nishimaki, Keiichi; Ito, Yasushi

    2016-01-01

    Background: Most dural arteriovenous fistula (DAVF) in superior sagittal sinus (SSS) requires multimodal treatment. Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. Case Description: A 59-year-old male presented with involuntary movements of both legs and progressive dementia. Cerebral angiography demonstrated the DAVF in the SSS fed by bilateral superficial temporal, occipital, and middle meningeal arteries. The posterior SSS was thrombosed, and the main drainers were cortical veins. Combined treatment with transarterial embolization using Onyx and transvenous embolization using coils was performed. Although symptoms were improved, a small DAVF remained. Two months later, Onyx cast extrusion through the scalp was observed, requiring removal and debridement because of infection at the extrusion sites. Surgery for the residual DAVF would be difficult because of scalp condition; therefore, an additional endovascular treatment was conducted, completely occluding DAVF. Conclusion: Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. Therefore, scalp infection should be considered because it may preclude additional surgical procedures. PMID:27313969

  20. Long-term follow-up analysis of microsurgical clip ligation and endovascular coil embolization for dorsal wall blister aneurysms of the internal carotid artery.

    PubMed

    Brown, Mason A; Guandique, Cristian F; Parish, Jonathan; McMillan, Aubrey C; Lehnert, Stephen; Mansour, Nassir; Tu, Michael; Bohnstedt, Bradley N; Payner, Troy D; Leipzig, Thomas J; DeNardo, Andrew J; Scott, John A; Cohen-Gadol, Aaron A

    2017-05-01

    Blister aneurysms at non-branching sites of the dorsal internal carotid artery (dICA) are fragile, rare, and often difficult to treat. The purpose of this study is to address the demographics, treatment modalities, and long-term outcome of patients treated for dICA blister aneurysms. A retrospective review of medical records identified all consecutive patients who presented with a blister aneurysm from 2002 to 2011 at our institution. Eighteen patients (M=7, F=11; mean age: 48.4±15.1years; range: 15-65years) harbored a total of 43 aneurysms, 25 of which were dorsal wall blister aneurysms of the ICA. Eleven (61.1%) patients presented with aneurysmal subarachnoid hemorrhage (aSAH), and 10 (55.6%) patients had multiple aneurysms at admission. Twelve patients had 18 aneurysms that were treated microsurgically. Five (41.7%) of these patients had a single recurrence that was retreated with subsequent repeat clip ligation. Six patients had 7 blister aneurysms that were treated with endovascularly. One (16.7%) of these patients had a single recurrence that was retreated with subsequent coil embolization. Postoperative vasospasm occurred in 8 (44.4%) patients, one of whom suffered from a stroke. This is one of the largest single-institution dICA blister aneurysm studies to date. There was no detected significant difference between microsurgical clip ligation and endovascular coil embolization in terms of surgical outcome. These blister aneurysms demonstrate a propensity to be associated with multiple cerebral aneurysms. Strict clinical and angiographic long-term follow-up may be warranted. Blister aneurysms are focal wall defects covered by a thin layer of fibrous tissue and adventitia, lacking the usual collagenous layer. Due to their pathologically thin vessel wall, blister aneurysms are prone to rupture. The management of these rare and fragile aneurysms presents a number of challenges. Here, we address the long-term outcome of patients treated for blister aneurysms at

  1. Piloted simulation study of a balloon-assisted deployment of an aircraft at high altitude

    NASA Technical Reports Server (NTRS)

    Murray, James; Moes, Timothy; Norlin, Ken; Bauer, Jeffrey; Geenen, Robert; Moulton, Bryan; Hoang, Stephen

    1992-01-01

    A piloted simulation was used to study the feasibility of a balloon assisted deployment of a research aircraft at high altitude. In the simulation study, an unmanned, modified sailplane was carried to 110,000 ft with a high altitude balloon and released in a nose down attitude. A remote pilot controlled the aircraft through a pullout and then executed a zoom climb to a trimmed, 1 g flight condition. A small parachute was used to limit the Mach number during the pullout to avoid adverse transonic effects. The use of small rocket motor was studied for increasing the maximum attainable altitude. Aerodynamic modifications to the basic sailplane included applying supercritical airfoil gloves over the existing wing and tail surfaces. The aerodynamic model of the simulated aircraft was based on low Reynolds number wind tunnel tests and computational techniques, and included large Mach number and Reynolds number effects at high altitude. Parametric variations were performed to study the effects of launch altitude, gross weight, Mach number limit, and parachute size on the maximum attainable stabilized altitude. A test altitude of approx. 95,000 ft was attained, and altitudes in excess of 100,000 ft was attained.

  2. High-Pressure Balloon-Assisted Stretching of the Coracohumeral Ligament to Determine the Optimal Stretching Positions: A Cadaveric Study.

    PubMed

    Baek, Sora; Lee, Kyu Jin; Kim, Keewon; Han, Seung-Ho; Lee, U-Young; Lee, Kun-Jai; Chung, Sun Gun

    2016-10-01

    assisted with an underlying pressure balloon were capable of decreasing CHL tightness. With further development and modification, high-pressure balloon-assisted stretching can be a potential therapeutic option to release tight CHL, including the advantage of augmenting and monitoring stretching intensity. II. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  3. [3-D angiography in diagnosis and treatment of intracranial aneurysm].

    PubMed

    Wang, D; Ling, F; Liu, S

    2001-09-01

    To summarize the results of initial application of three-dimensional angiography (3D-Angio) in diagnosis and treatment of intracranial aneurysms. From August 1999 to January 2001, standard digital subtraction angiography (two-dimensional angiography, 2D-Angio) and 3D-Angio(obtained by reconstruction of rotational angiography) were performed in 65 patients with confirmed or suspected aneurysms. Sixty-six aneurysms were found in 60 patients and nothing was found in 5. Of 66 the aneurysms (60 cases), 46 (43 cases) were treated by intrasaccule embolizotion with coils, 3 (3 cases) by occluding the parent artery with detachable balloon, 10 (10 cases) by surgery, and 1 (1 case) by combination of extracranial-intracranial bypass and balloon occlusion of parent artery. Six (3 cases) were not treated. Two aneurysms that could not be detected by 2D-Angio were diagnosed by 3D-Angio. Three aneurysms that were difficult or dangerous to embolize by 2D-Angio were embolized successfully with the help of 3D-Angio. Three aneurysms seemed to be embolized on 2D-Angio were proved impossible to be embolized on 3D-Angio. Of the 46 aneurysms embolized intrasaccularly, 38(82.6%) were completely embolized on 2D-Angio. In the 38, 8 had residual aneurysm on 3D-Angio. More accurate diagnosis and secure treatment of intracranial aneurysm can be reached by 3D-Angio.

  4. Giant intracranial aneurysm embolization with a yield stress fluid material: insights from CFD analysis.

    PubMed

    Wang, Weixiong; Graziano, Francesca; Russo, Vittorio; Ulm, Arthur J; De Kee, Daniel; Khismatullin, Damir B

    2013-01-01

    The endovascular treatment of intracranial aneurysms remains a challenge, especially when the aneurysm is large in size and has irregular, non-spherical geometry. In this paper, we use computational fluid dynamics to simulate blood flow in a vertebro-basilar junction giant aneurysm for the following three cases: (1) an empty aneurysm, (2) an aneurysm filled with platinum coils, and (3) an aneurysm filled with a yield stress fluid material. In the computational model, blood and the coil-filled region are treated as a non-Newtonian fluid and an isotropic porous medium, respectively. The results show that yield stress fluids can be used for aneurysm embolization provided the yield stress value is 20 Pa or higher. Specifically, flow recirculation in the aneurysm and the size of the inflow jet impingement zone on the aneurysm wall are substantially reduced by yield stress fluid treatment. Overall, this study opens up the possibility of using yield stress fluids for effective embolization of large-volume intracranial aneurysms.

  5. Direct Percutaneous Embolization of Bleeding Stomal Varices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naidu, Sailen G., E-mail: naidu.sailen@mayo.ed; Castle, Erik P.; Kriegshauser, J. Scott

    2010-02-15

    Stomal variceal bleeding can develop in patients with underlying cirrhosis and portal hypertension. Most patients are best treated with transjugular intrahepatic portosystemic shunt (TIPS) creation because this addresses the underlying problem of portal hypertension. However, some patients are not good candidates for TIPS creation because they have end-stage liver disease or encephalopathy. We describe such a patient who presented with recurrent bleeding stomal varices, which was successfully treated with percutaneous coil embolization. The patient had bleeding-free survival for 1 month before death from unrelated causes.

  6. Thrombus aspiration catheter is a Dottering balloon.

    PubMed

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate? Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  7. Mechanisms of perianeurysmal edema following endovascular embolization of aneurysms.

    PubMed

    Tomokiyo, M; Kazekawa, K; Onizuka, M; Aikawa, H; Tsutsumi, M; Ikoh, M; Kodama, T; Nii, K; Matsubara, S; Tanaka, A

    2007-03-15

    After coil embolization for an aneurysm, edema surrounding the aneurysm revealed by magnetic resonance imaging (MRI) is rarely seen and is usually associated with neurological symptoms. Perianeurysmal edema was found by postoperative MRI in three out of 182 patients with cerebral aneurysm, which was treated with Guglielmi Detachable Coil (GDC), and neurological symptoms developed simultaneously. In cases where neurological symptoms improved with conservative medical treatment, a temporary increase in the volume of an aneurysm, due to coil and thrombus formation, may result in edema. In cases where symptoms were not alleviated with conservative medical treatment, persistent water-hammer effect against the residual lumen of the aneurysm as well as an increase in the volume of aneurysm by hemorrhage in the aneurysmal wall may contribute to the development of perianeurysmal edema. Consideration of the mechanism of edema development by neurological symptoms, MRI findings, and angiographic findings is needed in order to select appropriate treatment.

  8. Mechanisms of Perianeurysmal Edema Following Endovascular Embolization of Aneurysms

    PubMed Central

    Tomokiyo, M.; K., Kazekawa; Onizuka, M.; Aikawa, H.; Tsutsumi, M.; Ikoh, M.; Kodama, T.; Nii, K.; Matsubara, S.; Tanaka, A.

    2007-01-01

    Summary After coil embolization for an aneurysm, edema surrounding the aneurysm revealed by magnetic resonance imaging (MRI) is rarely seen and is usually associated with neurological symptoms. Perianeurysmal edema was found by postoperative MRI in three out of 182 patients with cerebral aneurysm, which was treated with Guglielmi Detachable Coil (GDC), and neurological symptoms developed simultaneously. In cases where neurological symptoms improved with conservative medical treatment, a temporary increase in the volume of an aneurysm, due to coil and thrombus formation, may result in edema. In cases where symptoms were not alleviated with conservative medical treatment, persistent water-hammer effect against the residual lumen of the aneurysm as well as an increase in the volume of aneurysm by hemorrhage in the aneurysmal wall may contribute to the development of perianeurysmal edema. Consideration of the mechanism of edema development by neurological symptoms, MRI findings, and angiographic findings is needed in order to select appropriate treatment. PMID:20566093

  9. Carotid artery stenting with double cerebral embolic protection in asymptomatic patients - a diffusion-weighted MRI controlled study.

    PubMed

    Vuruskan, Ertan; Saracoglu, Erhan; Ergun, Ugur; Poyraz, Fatih; Duzen, İrfan Veysel

    2017-01-01

    The aim of this study was to compare the simultaneous double-protection method (proximal balloon plus distal filter) with distal-filter protection or proximal-balloon protection alone in asymptomatic patients during carotid artery stenting. 119 consecutive patients were investigated for carotid artery stentings in the extracranial internal carotid artery with the use of distal filters (n = 41, 34.4 %), proximal balloon (MoMa) protection (n = 40, 33.6 %) or double protection (n = 38, 31.9 %). Magnetic resonance imaging (MRI) was performed on all patients before the procedure, and control diffusion-weighted MRI (DW-MRI) was obtained within 24-48 h after the procedure. Procedural data, complications, success rate, major adverse cardiovascular events, and MRI findings were collected. New cerebral high-intensity (HI) lesions were observed in 47 (39.4 %) patients. HI lesions were observed in 22 (53.6 %), 15 (37.5 %), and 10 (26.3 %) of the patients with distal filters, proximal protection, and double protection, respectively (p = 0.004). The average number of HI lesions on DW-MRI was 1.80 in the distal-filter group, 0.90 in the proximal-balloon group, and 0.55 in the double-protection group (p < 0.001). Procedure and fluoroscopy times were slightly longer in the double-protection group compared to the distal- or proximal-protection groups (p = 0.001). The double (proximal plus distal) cerebral embolic protection technique is safe and effective for minimizing the risk of cerebral embolization, even in patients with asymptomatic carotid artery stenosis, despite slightly longer procedure and fluoroscopy times.
.

  10. Spontaneous Massive Hemothorax in a Patient with Neurofibromatosis Type 1 with Successful Transarterial Embolization

    PubMed Central

    Rookkapan, Sorracha; Tanutit, Pramot; Pakdeejit, Songklod; Songjamrat, Apiradee; Sungsiri, Jitpreedee

    2013-01-01

    Vascular involvement in neurofibromatosis type 1 is rare but has the potential to be fatal. We report a case of a patient with spontaneous rupture of a left intercostal artery aneurysm, which presented as a massive left hemothorax and was successfully treated by transarterial coil embolization. PMID:23323035

  11. Percutaneous transfacial direct embolization of an intraosseous dural arteriovenous fistula.

    PubMed

    Nerva, John D; Hallam, Danial K; Ghodke, Basavaraj V

    2014-03-01

    An intraosseous dural arteriovenous fistula (DAVF) is a rare cerebrovascular disease. The fistulous connection occurs within intraosseous diploic or transosseous emissary veins causing dilated intraosseous vascular pouches. To the authors' knowledge, this report describes the first percutaneous transfacial direct embolization of an intraosseous DAVF. A man in his 50s with blue rubber bleb nevus syndrome presented with headaches, imbalance, decreased visual acuity bilaterally, and left eye proptosis and chemosis. Imaging demonstrated an extensive intraosseous DAVF with dilated intraosseous vascular pouches throughout his cranial base and intraorbital venous congestion. He underwent staged endovascular treatment with the goal to improve his ocular symptoms. Transarterial and transvenous approaches failed to provide adequate access to the intraosseous vascular pouches. A direct, percutaneous transfacial approach was used to access the pouches for embolization with coils and liquid embolic material. Postoperative angiography demonstrated successful embolization of the pouch within the left pterygoid wing, reduced opacification of the intraosseous fistula, and elimination of intraorbital venous congestion. At 9-month follow-up, the patient's headaches had resolved, and his ocular symptomatology had improved. Endovascular access to an intraosseous DAVF is limited by the size and location of the intraosseous vascular pouches. In this case, a direct transfacial approach under image guidance facilitated access and embolization, which led to an improvement in the patient's symptoms. This technique is a novel approach for DAVF management.

  12. Very late stent thrombosis after sole stent-assisted coiling at the paraclinoid giant aneurysm : could prophylactic antiplatelet therapy be ceased at the only 1 year after procedure?

    PubMed

    Shin, Jung-Hoon; Park, Seong-Ho; Kim, Chang-Hyun; Lee, Chang-Young

    2014-10-01

    Stent thrombosis is a major limitation of stent-assisted coiling, which is an effective method for treating wide-necked aneurysms. Although early in-stent thrombosis has been reported, very late stent thrombosis (VLST) (>1 year) has not been reported following implantation of a single self-expandable stent designed for coiling. Herein, the authors present a case of VLST that occurred 14 months after single stent implantation in a large paraclinoid aneurysm with an ultra-wide neck involving the parent artery circumferentially. This case indicates the need for establishing guidelines regarding the optimal duration of prophylactic antiplatelet therapy following stent-assisted coiling, which remains undefined in the neuroendovascular field.

  13. Predictors of residual flow in embolized intracranial ruptured aneurysms at early follow-up.

    PubMed

    Serafin, Zbigniew; Strześniewski, Piotr; Beuth, Wojciech

    2014-01-01

    The possibility of recanalization and the need for retreatment are the most important drawbacks of intracranial aneurysm embolization. The purpose of the study was to prospectively analyze the results of early follow-up angiography of embolized ruptured aneurysms in an attempt to determine factors predicting the presence of residual flow. Evaluation included 72 patients with 72 aneurysms, which were followed-up 3 months after the treatment. Analysis of residual flow predictors included: age and gender, clinical state in Hunt-Hess scale, aneurysm localization, aneurysm three dimensions and volume, neck width, sac-to-neck ratio, initial result of embolization, number of coils used and the use of hydrogel coils and stents. Mean sac diameter was 6.5±3.9 mm, and mean neck width was 2.9±1.4 mm. Follow-up angiography presented residual flow in 26 aneurysms (36.1%): class 2 in 8 aneurysms (11.1%), and class 3 in 18 cases (25.0%). Stable aneurysm filling was observed in 45 cases (62.5%), progression of residual flow in 25 cases (34.7%), and regression in 2 cases (2.8%). According to ROC analysis independent predictors of residual flow were aneurysm neck diameter (AUC 0.857, 95% CI: 0.755-0.928, p<0.0001) and sac-to-neck ratio (AUC 0.817, 95% CI: 0.708-0.898, p<0.0001). Cut-off point of the ROC curve was established at 2.8 mm for neck diameter, and 1.73 for sac-to-neck ratio. Aneurysm neck diameter and sac-to-neck ratio are independently related to the residual flow in embolized ruptured aneurysms at early follow-up.

  14. Effect of Inductive Coil Geometry on the Thrust Efficiency of a Microwave Assisted Discharge Inductive Plasma Accelerator

    NASA Technical Reports Server (NTRS)

    Hallock, Ashley; Polzin, Kurt; Emsellem, Gregory

    2012-01-01

    Pulsed inductive plasma thrusters [1-3] are spacecraft propulsion devices in which electrical energy is capacitively stored and then discharged through an inductive coil. The thruster is electrodeless, with a time-varying current in the coil interacting with a plasma covering the face of the coil to induce a plasma current. Propellant is accelerated and expelled at a high exhaust velocity (O(10-100 km/s)) by the Lorentz body force arising from the interaction of the magnetic field and the induced plasma current. While this class of thruster mitigates the life-limiting issues associated with electrode erosion, pulsed inductive plasma thrusters require high pulse energies to inductively ionize propellant. The Microwave Assisted Discharge Inductive Plasma Accelerator (MAD-IPA) [4, 5] is a pulsed inductive plasma thruster that addressees this issue by partially ionizing propellant inside a conical inductive coil via an electron cyclotron resonance (ECR) discharge. The ECR plasma is produced using microwaves and permanent magnets that are arranged to create a thin resonance region along the inner surface of the coil, restricting plasma formation, and in turn current sheet formation, to a region where the magnetic coupling between the plasma and the inductive coil is high. The use of a conical theta-pinch coil is under investigation. The conical geometry serves to provide neutral propellant containment and plasma plume focusing that is improved relative to the more common planar geometry of the Pulsed Inductive Thruster (PIT) [2, 3], however a conical coil imparts a direct radial acceleration of the current sheet that serves to rapidly decouple the propellant from the coil, limiting the direct axial electromagnetic acceleration in favor of an indirect acceleration mechanism that requires significant heating of the propellant within the volume bounded by the current sheet. In this paper, we describe thrust stand measurements performed to characterize the performance

  15. Two Cases of Postmyomectomy Pseudoaneurysm Treated by Transarterial Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ito, Nobutake, E-mail: nobutake@rad.med.keio.ac.jp; Natimatsu, Yoshiaki; Tsukada, Jitsuro

    Pseudoaneurysm resulting from hysteroscopic myomectomy is a rare clinical situation, and interventional radiologists are not traditionally involved in the management. To our knowledge, endovascular treatment of a pseudoaneurysm resulting from hysteroscopic myomectomy has not yet been reported in the English-language literature. Here, two such cases are reported, including one of a woman who later became pregnant. The case is unique because little is known about the influence of unilateral coil embolization of the uterine artery on fertility.

  16. Management of Gastric Varices in the Pediatric Population with Balloon-Occluded Retrograde Transvenous Obliteration (BRTO) Utilizing Sodium Tetradecyl Sulfate Foam Sclerosis with or without Partial Splenic Artery Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saad, Wael E. A., E-mail: wspikes@yahoo.com; Anderson, Curtis L., E-mail: dranderson@southfloridavascular.com; Patel, Rahul S., E-mail: patelr516@gmail.com

    It is unknown whether spontaneous gastrorenal shunts actually develop in the pediatric population. The minimum age documented in studies from Asia is 32 (range 32–44) years. This study describes three pediatric patients undergoing balloon-occluded retrograde transvenous obliteration (BRTO) for bleeding gastric varices with two of the three patients undergoing combined partial splenic embolization. The first BRTO is a selective-BRTO via a surgical splenorenal shunt (15 years old) and the other two patients underwent conventional-BRTO via a spontaneous gastrorenal shunt (8 and 14 years old). The recurrent significant bleeding that they exhibited before the combined endovascular therapy did not recur for an averagemore » of 7.1 (range 1.4–14) months. In the second patient, quantitative digitally subtracted angiography was utilized to evaluate the inline portal venous flow before and after BRTO.« less

  17. Follow-up of intracranial aneurysms treated with stent-assisted coiling: Comparison of contrast-enhanced MRA, time-of-flight MRA, and digital subtraction angiography.

    PubMed

    Marciano, David; Soize, Sébastien; Metaxas, Georgios; Portefaix, Christophe; Pierot, Laurent

    2017-02-01

    Data about non-invasive follow-up of aneurysm after stent-assisted coiling is scarce. We aimed to compare time-of-flight (TOF) magnetic resonance angiography (MRA) (3D-TOF-MRA) and contrast-enhanced MRA (CE-MRA) at 3-Tesla, with digital subtraction angiography (DSA) for evaluating aneurysm occlusion and parent artery patency after stent-assisted coiling. In this retrospective single-center study, patients were included if they had an intracranial aneurysm treated by stent-assisted coiling between March 2008 and June 2015, followed with both MRA sequences (3D-TOF-MRA and CE-MRA) at 3-Tesla and DSA, performed in an interval<48hours. Thirty-five aneurysms were included. Regarding aneurysm occlusion evaluation, agreement with DSA was better for CE-MRA (K=0.53) than 3D-TOF-MRA (K=0.28). Diagnostic accuracies for aneurysm remnant depiction were similar for 3D-TOF-MRA and CE-MRA (P=1). Both 3D-TOF-MRA (K=0.05) and CE-MRA (K=-0.04) were unable to detect pathological vessel compared to DSA, without difference in accuracy (P=0.68). For parent artery occlusion detection, agreement with DSA was substantial for 3D-TOF-MRA (K=0.64) and moderate for CE-MRA (K=0.45), with similar good diagnostic accuracies (P=1). After stent-assisted coiling treatment, 3D-TOF-MRA and CE-MRA demonstrated good accuracy to detect aneurysm remnant (but tended to overestimation). Although CE-MRA agreement with DSA was better, there was no statistical difference between 3D-TOF-MRA and CE-MRA accuracies. Both MRAs were unable to provide a precise evaluation of in-stent status but could detect parent vessel occlusion. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. Selective transarterial embolization with n-butyl-2-cyanoacrylate for the treatment of arterial hemorrhage after third molar extraction.

    PubMed

    Sagara, Yoshiko; Kiyosue, Hiro; Tanoue, Shuichi; Shimada, Ryuichi; Hongo, Norio; Kohno, Tatsuyuki; Kawano, Kenji; Mori, Hiromu

    2013-06-01

    Comprehensive reports concerning selective embolization for arterial bleeding from third molar removal have not been published. We analyzed cases of arterial bleeding from third molar extraction that required transarterial embolization, and we demonstrate representative cases. Five consecutive patients (three men and two women, aged 24 to 37 years) who underwent transarterial embolization at our institution were included in this study. Four of them showed postoperative bleeding after lower third molar removal, and one suffered bleeding after upper third molar extraction. The period of time from extraction to embolization varied from 5 h to 5 weeks. Angiography revealed pseudoaneurysms at the inferior alveolar artery in four cases and at the superior alveolar artery in one case. The pseudoaneurysms were selectively embolized using 25-33 % n-butyl-2-cyanoacrylate (NBCA)-lipiodol. All of the cases showed good results angiographically and clinically. Transit hypoesthesia at the region of the mental nerve was observed in one patient. Selective transarterial embolization is an effective technique for arterial bleeding from third molar removal when it is difficult to obtain hemostasis by dental procedures. Injection of NBCA can be useful when the alveolar artery is too small to embolize with coils.

  19. Double Coaxial Microcatheter Technique for Glue Embolization of Renal Arteriovenous Malformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uchikawa, Yoko, E-mail: jauchikawa@gmail.com; Mori, Kensaku, E-mail: moriken@md.tsukuba.ac.jp; Shiigai, Masanari, E-mail: m-41gai@yahoo.co.jp

    PurposeTo demonstrate the technical benefit of the double coaxial microcatheter technique for embolization of renal arteriovenous malformations (AVMs) with n-butyl cyanoacrylate and iodized oil (glue).Materials and MethodsSix consecutive patients (1 man and 5 women; mean age 61 years; range 44–77 years) with renal AVMs were included. Five patients had hematuria, and one had a risk of heart failure due to a large intrarenal arteriovenous shunt. All patients underwent transarterial embolization using glue and the double coaxial microcatheter technique with outer 2.6F and inner 1.9F microcatheters. After glue injection, the inner microcatheter was retracted, while the outer microcatheter was retained. We assessed themore » complications and clinical outcomes of this technique.ResultsTechnical success was achieved in all patients. In 9 sessions, 34 feeding arteries were embolized with glue using the double coaxial microcatheter technique, 1 was embolized with glue using a single microcatheter, and 2 were embolized with coils. The double coaxial microcatheter technique was useful for selecting small tortuous feeding arteries, preventing glue reflux to the proximal arteries, and approaching multiple feeding arteries without complete retraction of the microcatheters. As a minor complication, glue migrated into the venous system in four patients without any sequelae. In all patients, favorable clinical outcomes, including hematuria cessation in five patients and improvement of the large intrarenal arteriovenous shunt in one patient, were obtained without deterioration of renal function.ConclusionGlue embolization with the double coaxial microcatheter technique was useful for treating renal AVMs with multiple tortuous feeding arteries.« less

  20. Balloon Blocking Technique (BBT) for Superselective Catheterization of Inaccessible Arteries with Conventional and Modified Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morishita, Hiroyuki, E-mail: hmorif@koto.kpu-m.ac.jp, E-mail: mori-h33@xa2.so-net.ne.jp; Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp; Ito, Takaaki, E-mail: takaaki@koto.kpu-m.ac.jp

    2016-06-15

    PurposeThe purpose of the study was to retrospectively evaluate the efficacy and safety of the balloon blocking technique (BBT).Materials and MethodsThe BBT was performed in six patients (all males, mean 73.5 years) in whom superselective catheterization for transcatheter arterial embolization by the conventional microcatheter techniques had failed due to anatomical difficulty, including targeted arteries originating steeply or hooked from parent arteries. All BBT procedures were performed using Seldinger’s transfemoral method. Occlusive balloons were deployed and inflated at the distal side of the target artery branching site in the parent artery via transfemoral access. A microcatheter was delivered from a 5-F cathetermore » via another femoral access and was advanced over the microguidewire into the target artery, under balloon blockage of advancement of the microguidewire into non-target branches. After the balloon catheter was deflated and withdrawn, optimal interventions were performed through the microcatheter.ResultsAfter success of accessing the targeted artery by BBT, optimal interventions were accomplished in all patients with no complications other than vasovagal hypotension, which responded to nominal therapy.ConclusionThe BBT may be useful in superselective catheterization of inaccessible arteries due to anatomical difficulties.« less

  1. GREAT-a randomized controlled trial comparing HydroSoft/HydroFrame and bare platinum coils for endovascular aneurysm treatment: procedural safety and core-lab-assessedangiographic results.

    PubMed

    Taschner, Christian A; Chapot, René; Costalat, Vincent; Machi, Paolo; Courthéoux, Patrick; Barreau, Xavier; Berge, Jérôme; Pierot, Laurent; Kadziolka, Kryzsztof; Jean, Betty; Blanc, Raphaël; Biondi, Alessandra; Brunel, Hervé; Gallas, Sophie; Berlis, Ansgar; Herbreteau, Denis; Berkefeld, Joachim; Urbach, Horst; El Shikh, Samer; Fiehler, Jens; Desal, Hubert; Graf, Erika; Bonafé, Alain

    2016-08-01

    Hybrid hydrogel-platinum coils (HydroCoil) have proven effective for endovascular aneurysm treatment. To overcome technical limitations (coil stiffness, time restriction for placement), a second generation of softer hydrogel coils has been brought to clinical practice (HydroSoft, HydroFrame). We report on procedural safety and core-lab-assessed angiographic results from an open-label multicenter randomized controlled trial. Web-based randomization occurred in 15 medical centers in France and seven in Germany between coil embolization with second-generation hydrogel coils and treatment with any bare platinum coil. Assist devices could be used as clinically required. Primary endpoint is a composite outcome including major aneurysm recurrence and poor clinical outcome at 18 months follow-up. Five hundred thirteen patients were randomized (hydrogel n = 256, bare platinum n = 257). Twenty patients were excluded for missing informed consent and nine patients for treatment related criteria. Four hundred eighty-four patients were analyzed as randomized (hydrogel n = 243, bare platinum n = 241). Two hundred eight had ruptured aneurysms (43 %). Prespecified procedural complications occurred in 58 subjects (hydrogel n = 28, bare platinum n = 30, p = 0.77). The 14-day mortality rate was 2.1 % in both arms of the study. The median calculated packing densities for aneurysms assigned to hydrogel and bare platinum were 39 and 31 % respectively (p < 0.001). No statistically significant differences were found between arms in the post procedural angiographic occlusion rate (p = 0.8). Second-generation hydrogel coils can be used in a wide spectrum of aneurysms with a risk profile equivalent to bare platinum. Packing density was significantly higher in aneurysms treated with hydrogel coils. http://www.germanctr.de , DRKS00003132.

  2. Fluoroscopy-free Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) for controlling life threatening postpartum hemorrhage

    PubMed Central

    Stensaeth, Knut Haakon; Sovik, Edmund; Haig, Ingrid Natasha Ylva; Skomedal, Erna; Jorgensen, Arve

    2017-01-01

    Background Severe postpartum hemorrhage occurs in 1/1000 women giving birth. This condition is often dramatic and may be life threatening. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) has in recent years been introduced as a novel treatment for hemorrhagic shock. We present a series of fluoroscopy-free REBOA for controlling life threatening postpartum hemorrhage. Methods In 2008 an ‘aortic occlusion kit’ was assembled and used in three Norwegian university hospitals. The on-call interventional radiologist (IR) was to be contacted with a response time < 30 minutes in case of life threatening PPH. Demographics and characteristics were noted from the medical records. Results This retrospective study includes 36 patients treated with fluoroscopy-free REBOA for controlling severe postpartum hemorrhage in the years 2008–2015. The REBOA success rate was 100% and no patients died from REBOA related complications. Uterine artery embolization was performed in 17 (47%) patients and a hysterectomy in 16 (44%) patients. A short (11cm) introducer length was strongly associated with iliac artery thrombus formation (ρ = 0.50, P = 0.002). In addition, there was a strong negative correlation between uterine artery embolization and hysterectomy (ρ = -0.50, P = 0.002). Conclusions Our Norwegian experience indicates the clinical safety and feasibility of REBOA in life threatening PPH. Also, REBOA can be used in an emergency situation without the use of fluoroscopy with a high degree of technical success. It is important that safety implementation of REBOA is established, especially through limited aortic balloon occlusion time and a thorough balloon deflation regime. PMID:28355242

  3. Application of chitosan-covered gauze in combination with intrauterine balloon tamponade for postpartum hemorrhage treatment - Case report of a novel "uterine sandwich" approach.

    PubMed

    Seidel, Vera; Braun, Thorsten; Weizsäcker, Katharina; Henrich, Wolfgang

    2018-05-26

    Postpartum or peripartum hemorrhage (PPH) is a major cause of maternal death worldwide. Fertility preserving second stage interventions following uterotonic medications may include compression sutures, uterine balloon tamponade and ligation or embolization of arteries. We present a case of PPH where a novel "uterine sandwich" approach (combination of chitosan-covered gauze with intrauterine balloon tamponade) was effectively used to stop further blood loss and prevented more invasive second stage interventions. Furthermore, we present the ultrasonographic image of chitosan-covered gauze in the uterine cavity. Chitosan-covered gauze and intrauterine balloon tamponade are complementary in their mechanism of work, the balloon reducing blood flow into the uterus and the chitosan-covered gauze enhancing the coagulation. This novel "uterine sandwich" approach can be a useful method for fertility preserving management of PPH. Copyright © 2018. Published by Elsevier Ltd.

  4. Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention.

    PubMed

    Kishino, Mitsuhiro; Nakaminato, Shuichiro; Kitazume, Yoshio; Miyasaka, Naoyuki; Kudo, Toshifumi; Saida, Yukihisa; Tateishi, Ukihide

    2018-07-01

    The usefulness of carbon dioxide (CO 2 ) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO 2 gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO 2 DSA (B-CO 2 DSA) as an improved CO 2 DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO 2 DSA and B-CO 2 DSA. B-CO 2 DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10-15 ml of CO 2 gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion. In all four cases, image quality was improved with B-CO 2 DSA; the poor quality of images without balloon occlusion was because of reflux of the CO 2 gas. B-CO 2 DSA improves the image quality of CO 2 DSA in the IIA region and is useful for vascular intervention. Level IV.

  5. Dense Accumulation of Lipiodol Emulsion in Hepatocellular Carcinoma Nodule during Selective Balloon-occluded Transarterial Chemoembolization: Measurement of Balloon-occluded Arterial Stump Pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irie, Toshiyuki, E-mail: toshiyuki.irie.rq@hitachi.com; Kuramochi, Masashi, E-mail: masashi.kuramochi.sh@hitachi.com; Takahashi, Nobuyuki, E-mail: nbyktakahashiodn@yahoo.co.jp

    2013-06-15

    Purpose. To reveal the mechanism of dense accumulation of lipiodol emulsion (LE) in hepatocellular carcinoma (HCC) during selective balloon-occluded transarterial chemoembolization (B-TACE). Methods. Balloon-occluded arterial stump pressure (BOASP) at the embolization portion was measured during selective B-TACE for 43 nodules in 42 patients. Fluoroscopy and digital subtraction angiography were prospectively observed during selective B-TACE to note whether dense LE accumulation in HCC occurred. The LE concentration ratio of HCC to embolized liver parenchyma (LECHL ratio) was also calculated for each treatment on the basis of the computed tomographic scan obtained immediately after selective B-TACE. The relationships between degree of LEmore » accumulation and the BOASP, as well as the LECHL ratio, were analyzed. Results. Arterial flow beyond the catheter tip was maintained even after balloon inflation. In 39 of 43 treatments, LE inflow into the nontumorous liver parenchyma ceased immediately after LE droplets were filled in arteries of the nontumorous liver parenchyma while LE inflow into the HCC nodule continued (group 1). More dense LE accumulation in HCC nodule was obtained in these 39 treatments. In four treatments, LE inflow both into the nontumorous liver parenchyma and into the HCC nodule continued, and no dense LE accumulation in HCC nodule was observed (group 2). In these four treatments, thick anastomotic vessels with collateral artery were noted. The BOASP in group 1 was (mean {+-} SD) 33.8 {+-} 12.8 mmHg (range 13-64 mmHg) and that in group 2 was 92.3 {+-} 7.4 mmHg (range 83-100 mmHg). There was a statistically significant difference in BOASP between groups (p = 0.00004, Welch's t test). The LECHL ratio in group 1 was 18.3 {+-} 13.9 (range 2.9-54.2) and that in group 2 was 2.6 {+-} 1.1 (range 1.7-4.2). There was a statistically significant difference in the LECHL ratio between the groups (p = 0.000034, Welch's t test). Conclusion. Selective B

  6. Type II Endoleak After Endovascular Repair of Abdominal Aortic Aneurysm: Effectiveness of Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nevala, Terhi, E-mail: Terhi.Nevala@ppshp.f; Biancari, Fausto; Manninen, Hannu

    2010-04-15

    The purpose of this study was to report our experience in treating type II endoleaks after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms. Two hundred eighteen patients underwent EVAR with a Zenith stent-graft from January 2000 to December 2005. During a follow-up period of 4.5 {+-} 2.3 years, solely type II endoleak was detected in 47 patients (22%), and 14 of them underwent secondary interventions to correct this condition. Ten patients had transarterial embolization, and four patients had translumbar/transabdominal embolization. The embolization materials used were coils, thrombin, gelatin, Onyx (ethylene-vinyl alcohol copolymer), and glue. Disappearance of the endoleak withoutmore » enlargement of the aneurysm sac after the first secondary intervention was achieved in only five of these patients (5/13). One patient without surveillance imaging was excluded from analyses of clinical success. After additional interventions in four patients and the spontaneous disappearance of type II endoleak in two patients, overall clinical success was achieved in eight patients (8/12). One patient did not have surveillance imaging after the second secondary intervention. Clinical success after the first secondary intervention was achieved in two patients (2/9) in the transarterial embolization group and three patients (3/4) in the translumbar embolization group. The results of secondary interventions for type II endoleak are unsatisfactory. Although the small number of patients included in this study prevents reliable comparisons between groups, the results seem to favor direct translumbar embolization in comparison to transarterial embolization.« less

  7. Snare-assisted anterograde balloon mitral and aortic valvotomy using Inoue balloon catheter.

    PubMed

    Krishnan, Mangalath N; Syamkumar, M D; Sajeev, C G; Venugopal, K; Johnson, Francis; Vinaykumar, D; Velayudhan, C C; Jayakumar, T G

    2007-01-02

    We performed concurrent antegrade mitral and aortic valvotomy using Inoue dilatation catheter in 3 cases of combined rheumatic mitral and aortic stenosis. Following mitral valvotomy by standard procedure, aortic valve was crossed with the help of a floatation catheter. Stiff long length guide wire was fixed in descending aorta using a snare. Inoue catheter was threaded over the wire across the aortic valve and aortic valvotomy completed. Mitral valve area increased from mean 1 cm2 to 2 cm2; aortic gradient dropped from mean of 97 mm to 36 mm. Concurrent anterograde balloon mitral and aortic valvotomy may be effective and safe.

  8. Posttraumatic carotid cavernous fistula that presented as seizure and focal neurological deficits with symptom resolution after therapeutic coil embolization.

    PubMed

    Klevtsova, Ekaterina; Nguyen-Min, Caroline; Lalani, Tania; Carlan, Stephen James; Madruga, Mario

    2015-02-01

    A posttraumatic carotid cavernous fistula can remain unrecognized and ultimately present with symptoms characteristic for a middle cerebral artery stroke. Progressive neurologic deterioration can occur until the condition is diagnosed and treated. If unrecognized and untreated, permanent damage may result. A 46-year-old white man with the history of a motor vehicle crash 6 months prior presented with complaints of acute onset of expressive aphasia and seizure-like activity for 3 days. On presentation, the patient was noted to have moderate proptosis and chemosis of the left eye. Magnetic resonance imaging of the brain showed an arteriovenous fistula arising from the anterolateral precavernous left internal carotid artery. This was directly communicating with the adjacent cortical veins along the medial aspect of the left temporal lobe, resulting in venous congestion in the left frontal opercular region, the left insula, and subinsular tracks. The patient underwent an intracranial coil embolization of a left carotid cavernous fistula. No complications were encountered, and the patient had near-complete resolution of neurologic deficits and left eye proptosis. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Although posttraumatic carotid cavernous fistula is a rare condition, it is important to be aware of this entity because immediate diagnosis and treatment may improve outcome. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. On the feasibility of closed-loop control of intra-aortic balloon pumping

    NASA Technical Reports Server (NTRS)

    Clark, J. W., Jr.; Bourland, H. M.; Kane, G. R.

    1973-01-01

    A closed-loop control scheme for the control of intra-aortic balloon pumping has been developed and tested in dog experiments. A performance index reflecting the general objectives of balloon-assist pumping is developed and a modified steepest ascent control algorithm is utilized for the selection of a proper operating point for the balloon during its pumping cycle. This paper attempts to indicate the feasibility of closed-loop control of balloon pumping, and particularly its flexibility in achieving both diastolic augmentation of mean aortic pressure and control of the level of end-diastolic pressure (EDP) an important factor in reducing heart work.

  10. Double balloon protection during carotid artery stenting for vulnerable carotid stenosis reduces the incidence of new brain lesions.

    PubMed

    Nakazaki, Masahito; Nonaka, Tadashi; Takahashi, Akira; Yonemasu, Yasuyuki; Nomura, Tatsufumi; Onda, Toshiyuki; Honda, Osamu; Hashimoto, Yuji; Ohnishi, Hirofumi; Sasaki, Masanori; Daibo, Masahiko; Honmou, Osamu

    2016-07-01

    The use of distal filter protection alone is associated with a high risk of ischemic complications when vulnerable carotid stenosis is treated by carotid artery stenting (CAS). Double balloon protection, a combination of distal balloon protection and proximal balloon occlusion, can be utilized. We assessed the outcome and complications of the double balloon protection method for vulnerable carotid stenosis. Among 130 patients who underwent CAS from 2009 to 2014, we enrolled the following patients: those whose target lesion was vulnerable as evaluated by MRI, i.e., a signal ratio of plaque to posterior cervical muscle on T1-weighted images before CAS of ≥1.5, and those who underwent diffusion-weighted imaging (DWI) studies within 48 h after the procedure. Ninety patients were enrolled. We investigated DWI findings of the double balloon protection group compared with those of the simple distal balloon protection and distal filter protection groups. Sixty-four patients (71 %) underwent double balloon protection, 15 patients (17 %) simple distal balloon protection, and 11 patients (12 %) distal filter protection. Symptomatic embolic complications and new lesions on DWI after CAS were significantly less common in patients undergoing double balloon protection compared to distal balloon protection or distal filter protection (0 % vs. 20 %, 9 %, P < 0.01, and 30 % vs. 67 %, 82 %, P < 0.01, respectively). Logistic regression analysis also identified the odds ratio of double balloon protection for new lesions on DWI after CAS of 0.23 (95 % confidence interval: 0.07-0.70, P < 0.01) compared to simple distal protections. In the patients who underwent CAS for vulnerable carotid stenosis, double balloon protection was an independent significant factor associated with a reduction in the risk of new lesions on DWI after the procedure compared to conventional distal protections.

  11. A novel balloon colonoscope detects significantly more simulated polyps than a standard colonoscope in a colon model.

    PubMed

    Hasan, Nazia; Gross, Seth A; Gralnek, Ian M; Pochapin, Mark; Kiesslich, Ralf; Halpern, Zamir

    2014-12-01

    Although standard colonoscopy is considered the optimal test to detect adenomas, it can have a significant adenoma miss rate. A major contributing factor to high miss rates is the inability to visualize adenomas behind haustral folds and at anatomic flexures. To compare the diagnostic yield of balloon-assisted colonoscopy versus standard colonoscopy in the detection of simulated polyps in a colon model. Prospective, cohort study. International gastroenterology meeting. A colon model composed of elastic material, which mimics the flexible structure of haustral folds, allowing for dynamic responses to balloon inflation, with embedded simulated colon polyps (n = 12 silicone "polyps"). Fifty gastroenterologists were recruited to identify simulated colon polyps in a colon model, first using standard colonoscopy immediately followed by balloon-assisted colonoscopy. Detection of simulated polyps. The median polyp detection rate for all simulated polyps was significantly higher with balloon-assisted as compared with standard colonoscopy (91.7% vs 45.8%, respectively; P < .0001). The significantly higher simulated polyp detection rate with balloon-assisted versus standard colonoscopy was notable both for non-obscured polyps (100.0% vs 75.0%; P < .0001) and obscured polyps (88.0% vs 25.0%; P < .0001). Non-randomized design, use of a colon model, and simulated colon polyps. As compared with standard colonoscopy, balloon-assisted colonoscopy detected significantly more obscured and non-obscured simulated polyps in a colon model. Clinical studies in human participants are being pursued to further evaluate this new colonoscopic technology. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  12. Coronary and peripheral stenting in aorto-ostial protruding stents: The balloon assisted access to protruding stent technique.

    PubMed

    Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R

    2016-03-01

    Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.

  13. Incidental occlusion of anterior spinal artery due to Onyx reflux in embolization of spinal type II arteriovenous malformation.

    PubMed

    Kim, Joohyun; Lee, Jang-Bo; Cho, Tai-Hyoung; Hur, Junseok W

    2017-05-01

    Onyx embolization is one of the standard treatments for brain arteriovenous malformations (AVMs) and is a promising method for spinal AVMs as well. Its advantages have been emphasized, and few complications have been reported with Onyx embolization in spinal AVMs. Here, we report an incidental anterior spinal artery (ASA) occlusion due to Onyx reflux during embolization of a spinal type II AVM. A 15-year-old boy presented with weakness in both upper and lower extremities. Magnetic resonance imaging and spinal angiogram revealed a spinal type II AVM with two feeders including the right vertebral artery (VA) and the right deep cervical artery. Onyx embolization was performed gradually from the VA to the deep cervical artery and an unexpected Onyx reflux to the ASA was observed during the latter stage deep cervical artery embolization. Post-operative quadriplegia and low cranial nerves (CN) dysfunction were observed. Rehabilitation treatment was performed and the patient showed marked improvement of neurologic deterioration at 1-year follow-up. Onyx is an effective treatment choice for spinal AVMs. However, due to the small vasculature of the spine compared to the brain, the nidus is rapidly packed with a small amount of Onyx, which allows Onyx reflux to unexpected vessels. Extreme caution is required and dual-lumen balloon catheter could be considered for Onyx embolization in spinal AVMs treatment.

  14. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up ofmore » 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.« less

  15. Resolution of Oculomotor Nerve Palsy Secondary to Posterior Communicating Artery Aneurysms: Comparison of Clipping and Coiling.

    PubMed

    McCracken, D Jay; Lovasik, Brendan P; McCracken, Courtney E; Caplan, Justin M; Turan, Nefize; Nogueira, Raul G; Cawley, C Michael; Dion, Jacques E; Tamargo, Rafael J; Barrow, Daniel L; Pradilla, Gustavo

    2015-12-01

    Previous studies have attempted to determine the best treatment for oculomotor nerve palsy (ONP) secondary to posterior communicating artery (PCoA) aneurysms, but have been limited by small sample sizes and limited treatment. To analyze the treatment of ONP secondary to PCoA with both coiling and clipping in ruptured and unruptured aneurysms. Data from 2 large academic centers was retrospectively collected over 22 years, yielding a total of 93 patients with ONP secondary to PCoA aneurysms. These patients were combined with 321 patients from the literature review for large data analyses. Onset symptoms, recovery, and time to resolution were evaluated with respect to treatment and aneurysm rupture status. For all patients presenting with ONP (n = 414) 56.6% of those treated with microsurgical clipping made a full recovery vs 41.5% of those treated with endovascular coil embolization (P = .02). Of patients with a complete ONP (n = 229), full recovery occurred in 47.3% of those treated with clipping but in only 20% of those undergoing coiling (P = .01). For patients presenting with ruptured aneurysms (n = 130), full recovery occurred in 70.9% compared with 49.3% coiled patients (P = .01). Additionally, although patients with full ONP recovery had a median time to treatment of 4 days, those without full ONP recovery had a median time to treatment of 7 days (P = .01). Patients with ONP secondary to PCoA aneurysms treated with clipping showed higher rates of full ONP resolution than patients treated with coil embolization. Larger prospective studies are needed to determine the true potential of recovery associated with each treatment. EUH, Emory University HospitalIQR, interquartile rangeJHU, Johns Hopkins UniversitymRS, modified Rankin ScaleONP, oculomotor nerve palsyPCoA, posterior communicating arterySAH, subarachnoid hemorrhage.

  16. Ballooning Then...and Ballooning Now.

    ERIC Educational Resources Information Center

    Journal of Aerospace Education, 1978

    1978-01-01

    Describes the history of hot-air balloon travel, starting with its French origins and continuing through to the 1978 national championship. An address for Balloon Federation of America membership is included. (MA)

  17. Hybrid approach to surgical correction of tetralogy of Fallot in all patients with functioning Blalock Taussig shunts.

    PubMed

    Sivakumar, Kothandam; Krishnan, Prasad; Pieris, Rajeeva; Francis, Edwin

    2007-08-01

    In total surgical correction of tetralogy of Fallot (TOF) with functioning Blalock Taussig shunts (BTS), shunt take down increased surgical time, bleeding, and might injure phrenic and recurrent laryngeal nerve and thoracic duct. A routine hybrid approach using transcatheter BTS closure immediately before total surgical correction of TOF in all patients might reduce these problems. We analyze the safety and feasibility of this approach. Transcatheter BTS closure was achieved using single or multiple stainless steel embolization coils, Amplatzer vascular plugs, or duct occluders. When coils were released without control by bioptome forceps, coil migration in larger shunts was prevented by proximal or distal balloon occlusion. This routine hybrid strategy was followed in 22 consecutive patients aged 1-13 years over 4-year-period and 21 procedures were successful. Among the 16 patients attempted with coils, 13 had successful closure, 2 needed Amplatzer duct occluder devices, and 1 sent for surgical shunt takedown due to acute angulation of the shunt. New Amplatzer vascular plugs were used in six patients. Bioptome was used in six patients and proximal or distal balloon occlusion of flow was used in three patients. Four patients had closure of associated aortopulmonary or chest wall collaterals. Hybrid approach using routine transcatheter closure of all BTS immediately before surgical correction of TOF shunts with coils/plugs/devices is safe, feasible, and reproducible. Copyright (c) 2007 Wiley-Liss, Inc.

  18. In vitro study of near-wall flow in a cerebral aneurysm model with and without coils.

    PubMed

    Goubergrits, L; Thamsen, B; Berthe, A; Poethke, J; Kertzscher, U; Affeld, K; Petz, C; Hege, H-C; Hoch, H; Spuler, A

    2010-09-01

    Coil embolization procedures change the flow conditions in the cerebral aneurysm and, therefore, in the near-wall region. Knowledge of these flow changes may be helpful to optimize therapy. The goal of this study was to investigate the effect of the coil-packing attenuation on the near-wall flow and its variability due to differences in the coil structure. An enlarged transparent model of an ACA aneurysm was fabricated on the basis of CT angiography. The near-wall flow was visualized by using a recently proposed technique called Wall-PIV. Coil-packing attenuation of 10%, 15%, and 20% were investigated and compared with an aneurysmal flow without coils. Then the flow variability due to the coil introduction was analyzed in 10 experiments by using a packing attenuation of 15%. A small packing attenuation of 10% already alters the near-wall flow significantly in a large part of the aneurysmal sac. These flow changes are characterized by a slow flow with short (interrupted) path lines. An increased packing attenuation expands the wall area exposed to the altered flow conditions. This area, however, depends on the coil position and/or on the 3D coil structure in the aneurysm. To our knowledge, this is the first time the near-wall flow changes caused by coils in an aneurysm model have been visualized. It can be concluded that future hydrodynamic studies of coil therapy should include an investigation of the coil structure in addition to the coil-packing attenuation.

  19. Celiac trunk embolization, as a means of elongating short distal descending thoracic aortic aneurysm necks, prior to endovascular aortic repair.

    PubMed

    Belenky, Alexander; Haddad, Menashe; Idov, Igor; Knizhnik, Michael; Litvin, Sergey; Bachar, Gil N; Atar, Eli

    2009-09-01

    The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization -- only if the superior and inferior mesenteric arteries are patent -- is a good and safe way to elongate the neck and enable EVAR.

  20. Celiac Trunk Embolization, as a Means of Elongating Short Distal Descending Thoracic Aortic Aneurysm Necks, Prior to Endovascular Aortic Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belenky, Alexander; Haddad, Menashe; Idov, Igor

    2009-09-15

    The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first yearmore » and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.« less

  1. Molecular clamp mechanism of substrate binding by hydrophobic coiled-coil residues of the archaeal chaperone prefoldin

    PubMed Central

    Lundin, Victor F.; Stirling, Peter C.; Gomez-Reino, Juan; Mwenifumbo, Jill C.; Obst, Jennifer M.; Valpuesta, José M.; Leroux, Michel R.

    2004-01-01

    Prefoldin (PFD) is a jellyfish-shaped molecular chaperone that has been proposed to play a general role in de novo protein folding in archaea and is known to assist the biogenesis of actins, tubulins, and potentially other proteins in eukaryotes. Using point mutants, chimeras, and intradomain swap variants, we show that the six coiledcoil tentacles of archaeal PFD act in concert to bind and stabilize nonnative proteins near the opening of the cavity they form. Importantly, the interaction between chaperone and substrate depends on the mostly buried interhelical hydrophobic residues of the coiled coils. We also show by electron microscopy that the tentacles can undergo an en bloc movement to accommodate an unfolded substrate. Our data reveal how archael PFD uses its unique architecture and intrinsic coiled-coil properties to interact with nonnative polypeptides. PMID:15070724

  2. Application of a novel metal artifact correction algorithm in flat-panel CT after coil embolization of brain aneurysms: intraindividual comparison.

    PubMed

    Buhk, J-H; Groth, M; Sehner, S; Fiehler, J; Schmidt, N O; Grzyska, U

    2013-09-01

    To evaluate a novel algorithm for correcting beam hardening artifacts caused by metal implants in computed tomography performed on a C-arm angiography system equipped with a flat panel (FP-CT). 16 datasets of cerebral FP-CT acquisitions after coil embolization of brain aneurysms in the context of acute subarachnoid hemorrhage have been reconstructed by applying a soft tissue kernel with and without a novel reconstruction filter for metal artifact correction. Image reading was performed in multiplanar reformations (MPR) in average mode on a dedicated radiological workplace in comparison to the preinterventional native multisection CT (MS-CT) scan serving as the anatomic gold standard. Two independent radiologists performed image scoring following a defined scale in direct comparison of the image data with and without artifact correction. For statistical analysis, a random intercept model was calculated. The inter-rater agreement was very high (ICC = 86.3 %). The soft tissue image quality and visualization of the CSF spaces at the level of the implants was substantially improved. The additional metal artifact correction algorithm did not induce impairment of the subjective image quality in any other brain regions. Adding metal artifact correction to FP-CT in an acute postinterventional setting helps to visualize the close vicinity of the aneurysm at a generally consistent image quality. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Utility of the balloon-overtube-assisted modified over-the-wire stenting technique to treat post-sleeve gastrectomy complications.

    PubMed

    Ponte, Ana; Pinho, Rolando; Proença, Luísa; Silva, Joana; Rodrigues, Jaime; Sousa, Mafalda; Silva, João Carlos; Carvalho, João

    2017-06-16

    To describe a modified technique of deployment of stents using the overtube developed for balloon-assisted enteroscopy in post-sleeve gastrectomy (SG) complications. Between January 2010 and December 2015, all patients submitted to an endoscopic stenting procedure to treat a post-SG stenosis or leakage were retrospectively collected. Procedures from patients in which the stent was deployed using the balloon-overtube-assisted modified over-the-wire (OTW) stenting technique were described. The technical success, corresponding to proper placement of the stent in the stomach resulting in exclusion of the SG leak or the stenosis, was evaluated. Complications related to stenting were also reported. Five procedures were included to treat 2 staple line leaks and 3 stenoses. Two types of stents were used, including a fully covered self-expandable metal stent designed for the SG anatomy (Hanarostent, ECBB-30-240-090; M.I. Tech, Co., Ltd, Seoul, South Korea) in 4 procedures and a biodegradable stent (BD stent 019-10A-25/20/25-080, SX-ELLA, Hradec Kralove, Czech Republic) in the remaining procedure. In all cases, an overtube was advanced with the endoscope through the SG to the duodenum. After placement of the guidewire and removal of the endoscope, the stent was easily advanced through the overtube. The overtube was pulled back and the stent was successfully deployed under fluoroscopic guidance. Technical success was achieved in all patients. The adoption of a modified technique of deployment of OTW stents using an overtube may represent an effective option in the approach of SG complications.

  4. Utility of the balloon-overtube-assisted modified over-the-wire stenting technique to treat post-sleeve gastrectomy complications

    PubMed Central

    Ponte, Ana; Pinho, Rolando; Proença, Luísa; Silva, Joana; Rodrigues, Jaime; Sousa, Mafalda; Silva, João Carlos; Carvalho, João

    2017-01-01

    AIM To describe a modified technique of deployment of stents using the overtube developed for balloon-assisted enteroscopy in post-sleeve gastrectomy (SG) complications. METHODS Between January 2010 and December 2015, all patients submitted to an endoscopic stenting procedure to treat a post-SG stenosis or leakage were retrospectively collected. Procedures from patients in which the stent was deployed using the balloon-overtube-assisted modified over-the-wire (OTW) stenting technique were described. The technical success, corresponding to proper placement of the stent in the stomach resulting in exclusion of the SG leak or the stenosis, was evaluated. Complications related to stenting were also reported. RESULTS Five procedures were included to treat 2 staple line leaks and 3 stenoses. Two types of stents were used, including a fully covered self-expandable metal stent designed for the SG anatomy (Hanarostent, ECBB-30-240-090; M.I. Tech, Co., Ltd, Seoul, South Korea) in 4 procedures and a biodegradable stent (BD stent 019-10A-25/20/25-080, SX-ELLA, Hradec Kralove, Czech Republic) in the remaining procedure. In all cases, an overtube was advanced with the endoscope through the SG to the duodenum. After placement of the guidewire and removal of the endoscope, the stent was easily advanced through the overtube. The overtube was pulled back and the stent was successfully deployed under fluoroscopic guidance. Technical success was achieved in all patients. CONCLUSION The adoption of a modified technique of deployment of OTW stents using an overtube may represent an effective option in the approach of SG complications. PMID:28690770

  5. Early outcomes of empiric embolization of tumor-related gastrointestinal hemorrhage in patients with advanced malignancy.

    PubMed

    Tandberg, Daniel J; Smith, Tony P; Suhocki, Paul V; Pabon-Ramos, Waleska; Nelson, Rendon C; Desai, Svetang; Branch, Stanley; Kim, Charles Y

    2012-11-01

    To report short-term results of empiric transcatheter embolization for patients with advanced malignancy and gastrointestinal (GI) hemorrhage directly from a tumor invading the GI tract wall. Between 2005 and 2011, 37 mesenteric angiograms were obtained in 26 patients with advanced malignancy (20 men, six women; mean age, 56.2 y) with endoscopically confirmed symptomatic GI hemorrhage from a tumor invading the GI tract wall. Angiographic findings and clinical outcomes were retrospectively evaluated. Clinical success was defined as absence of signs and symptoms of hemorrhage for at least 30 day following embolization. Active extravasation was demonstrated in three cases. Angiographic abnormalities related to a GI tract tumor were identified on 35 of 37 angiograms, including tumor neovascularity (n = 21), tumor enhancement (n = 24), and luminal irregularity (n = 5). In the absence of active extravasation, empiric embolization with particles and/or coils was performed in 25 procedures. Cessation of hemorrhage (ie, clinical success) occurred more frequently when empiric embolization was performed (17 of 25 procedures; 68%) than when embolization was not performed (two of nine; 22%; P = .03). Empiric embolization resulted in clinical success in 10 of 11 patients with acute GI bleeding (91%), compared with seven of 14 patients (50%) with chronic GI bleeding (P = .04). No ischemic complications were encountered. In patients with advanced malignancy, in the absence of active extravasation, empiric transcatheter arterial embolization for treatment of GI hemorrhage from a direct tumor source demonstrated a 68% short-term success rate, without any ischemic complications. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  6. Percutaneous intraportal application of adipose tissue-derived mesenchymal stem cells using a balloon occlusion catheter in a porcine model of liver fibrosis.

    PubMed

    Avritscher, Rony; Abdelsalam, Mohamed E; Javadi, Sanaz; Ensor, Joe; Wallace, Michael J; Alt, Eckhard; Madoff, David C; Vykoukal, Jody V

    2013-12-01

    To investigate the safety and effectiveness of a novel endovascular approach for therapeutic cell delivery using a balloon occlusion catheter in a large animal model of liver fibrosis. Transcatheter arterial embolization with ethiodized oil (Ethiodol) and ethanol was used to induce liver damage in 11 pigs. Mesenchymal stem cells (MSCs) were harvested from adipose tissue and engineered to express green fluorescent protein (GFP). A balloon occlusion catheter was positioned in the bilateral first-order portal vein branches 2 weeks after embolization to allow intraportal application of MSCs in six experimental animals. MSCs were allowed to dwell for 10 minutes using prolonged balloon inflation. Five control animals received a sham injection of normal saline in a similar fashion. Hepatic venous pressure gradient (HVPG) was measured immediately before necropsy. Specimens from all accessible lobes were obtained with ultrasound-guided percutaneous 18-gauge biopsy 2 hours after cell application. All animals were euthanized within 4 weeks. Fluorescent microscopy was used to assess the presence and distribution of cells. Liver injury and fibrosis were successfully induced in all animals. MSCs (6-10 × 10(7)) were successfully delivered into the portal vein in the six experimental animals. Cell application was not associated with vascular complications. HVPG showed no instances of portal hypertension. GFP-expressing MSCs were visualized in biopsy specimens and were distributed primarily within the sinusoidal spaces; however, 4 weeks after implantation, MSCs could not be identified in histologic specimens. A percutaneous endovascular approach for cell delivery using a balloon occlusion catheter proved safe for intraportal MSC application in a large animal model of liver fibrosis. © 2013 SIR Published by SIR All rights reserved.

  7. Computational fluid dynamics (CFD) using porous media modeling predicts recurrence after coiling of cerebral aneurysms.

    PubMed

    Umeda, Yasuyuki; Ishida, Fujimaro; Tsuji, Masanori; Furukawa, Kazuhiro; Shiba, Masato; Yasuda, Ryuta; Toma, Naoki; Sakaida, Hiroshi; Suzuki, Hidenori

    2017-01-01

    This study aimed to predict recurrence after coil embolization of unruptured cerebral aneurysms with computational fluid dynamics (CFD) using porous media modeling (porous media CFD). A total of 37 unruptured cerebral aneurysms treated with coiling were analyzed using follow-up angiograms, simulated CFD prior to coiling (control CFD), and porous media CFD. Coiled aneurysms were classified into stable or recurrence groups according to follow-up angiogram findings. Morphological parameters, coil packing density, and hemodynamic variables were evaluated for their correlations with aneurysmal recurrence. We also calculated residual flow volumes (RFVs), a novel hemodynamic parameter used to quantify the residual aneurysm volume after simulated coiling, which has a mean fluid domain > 1.0 cm/s. Follow-up angiograms showed 24 aneurysms in the stable group and 13 in the recurrence group. Mann-Whitney U test demonstrated that maximum size, dome volume, neck width, neck area, and coil packing density were significantly different between the two groups (P < 0.05). Among the hemodynamic parameters, aneurysms in the recurrence group had significantly larger inflow and outflow areas in the control CFD and larger RFVs in the porous media CFD. Multivariate logistic regression analyses demonstrated that RFV was the only independently significant factor (odds ratio, 1.06; 95% confidence interval, 1.01-1.11; P = 0.016). The study findings suggest that RFV collected under porous media modeling predicts the recurrence of coiled aneurysms.

  8. Egress door opening assister

    DOEpatents

    Allison, Thomas L.

    2015-10-06

    A door opening spring assistance apparatus is set forth that will automatically apply a door opening assistance force using a combination of rods and coil springs. The release of the rods by the coil springs reduces the force required to set the door in motion.

  9. α/β coiled coils

    PubMed Central

    Hartmann, Marcus D; Mendler, Claudia T; Bassler, Jens; Karamichali, Ioanna; Ridderbusch, Oswin; Lupas, Andrei N; Hernandez Alvarez, Birte

    2016-01-01

    Coiled coils are the best-understood protein fold, as their backbone structure can uniquely be described by parametric equations. This level of understanding has allowed their manipulation in unprecedented detail. They do not seem a likely source of surprises, yet we describe here the unexpected formation of a new type of fiber by the simple insertion of two or six residues into the underlying heptad repeat of a parallel, trimeric coiled coil. These insertions strain the supercoil to the breaking point, causing the local formation of short β-strands, which move the path of the chain by 120° around the trimer axis. The result is an α/β coiled coil, which retains only one backbone hydrogen bond per repeat unit from the parent coiled coil. Our results show that a substantially novel backbone structure is possible within the allowed regions of the Ramachandran space with only minor mutations to a known fold. DOI: http://dx.doi.org/10.7554/eLife.11861.001 PMID:26771248

  10. Feasibility of Using Intravascular Ultrasonography for Assessment of Giant Cavernous Aneurysm after Endovascular Treatment: A Technical Report

    PubMed Central

    Majidi, Shahram; Grigoryan, Mikayel; Tekle, Wondwossen G; Watanabe, Masaki; Qureshi, Adnan I

    2012-01-01

    Introduction Intravascular ultrasonography (IVUS) has been shown as a valuable adjunct imaging tool during endovascular procedures but its value in detection of any recurrence during follow up after endovascular coil embolization of large and giant intracranial aneurysms is not reported. Methods A 41 years old man who had been treated using stent assisted coil embolization for cavernous segment aneurysm of the left internal carotid artery underwent 60 month angiographic follow up. Concurrently, IVUS catheter was advanced under fluoroscopic guidance inside the cavernous portion of the left internal carotid artery. Then IVUS images were used to visualize the stent, coil loops, and aneurysm neck. Results The angiographic images were limited because of superimposition of the aneurysm on the parent vessel in all projections. IVUS images demonstrated that the stent was patent along its whole length and there was no sign of stent deformity or in-stent thrombosis. Loops of the coil were visualized as hyperechoic signals inside the aneurysm and there was no sign of herniated loops of coil inside the stent. Conclusion In this case report, we observed that adjunct use of IVUS can provide valuable information not ascertained by angiography during follow up assessment of coil embolized aneurysm. PMID:22737259

  11. Percutaneous Direct Needle Puncture and Transcatheter N-butyl Cyanoacrylate Injection Techniques for the Embolization of Pseudoaneurysms and Aneurysms of Arteries Supplying the Hepato-pancreato-biliary System and Gastrointestinal Tract

    PubMed Central

    Yadav, Rajanikant R; Boruah, Deb K; Bhattacharyya, Vishwaroop; Prasad, Raghunandan; Kumar, Sheo; Saraswat, V A; Kapoor, V K; Saxena, Rajan

    2016-01-01

    Aims: The aim of this study was to evaluate the safety and clinical efficacy of percutaneous direct needle puncture and transcatheter N-butyl cyanoacrylate (NBCA) injection techniques for the embolization of pseudoaneurysms and aneurysms of arteries supplying the hepato-pancreato-biliary (HPB) system and gastrointestinal (GI) tract. Subjects and Methods: A hospital-based cross-sectional retrospective study was conducted, where the study group comprised 11 patients with pseudoaneurysms/aneurysms of arteries supplying the HPB system and GI tract presenting to a tertiary care center from January 2015 to June 2016. Four patients (36.4%) underwent percutaneous direct needle puncture of pseudoaneurysms with NBCA injection, 3 patients (27.3%) underwent transcatheter embolization with NBCA as sole embolic agent, and in 4 patients (36.4%), transcatheter NBCA injection was done along with coil embolization. Results: This retrospective study comprised 11 patients (8 males and 3 females) with mean age of 35.8 years ± 1.6 (standard deviation [SD]). The mean volume of NBCA: ethiodized oil (lipiodol) mixture injected by percutaneous direct needle puncture was 0.62 ml ± 0.25 (SD) (range = 0.5–1 ml), and by transcatheter injection, it was 0.62 ml ± 0.37 (SD) (range = 0.3–1.4 ml). Embolization with NBCA was technically and clinically successful in all patients (100%). No recurrence of bleeding or recurrence of pseudoaneurysm/aneurysm was noted in our study. Conclusions: Percutaneous direct needle puncture of visceral artery pseudoaneurysms and NBCA glue injection and transcatheter NBCA injection for embolization of visceral artery pseudoaneurysms and aneurysms are cost-effective techniques that can be used when coil embolization is not feasible or has failed. PMID:28123838

  12. Vascular Plug Assisted Retrograde Transvenous Obliteration (PARTO) for Gastric Varix Bleeding Patients in the Emergent Clinical Setting

    PubMed Central

    Yang, Heechul; Lee, Chun Kyon; Kim, Gun Bea

    2016-01-01

    Purpose To evaluate the technical feasibility and safety of vascular plug assisted retrograde transvenous obliteration (PARTO) for bleeding gastric varix performed in the emergent clinical setting and describe the mid-term clinical results. Materials and Methods From April 2012 to January 2015, emergent PARTO was tried in total 9 patients presented with active gastric varix bleeding. After initial insufficient or failure of endoscopic approach, they underwent PARTO in the emergent clinical setting. Gelatin sponge embolization of both gastrorenal (GR) shunt and gastric varix was performed after retrograde transvenous placement of a vascular plug in GR shunt. Coil assisted RTO (CARTO) was performed in one patient who had challenging GR shunt anatomy for vascular plug placement. Additional embolic materials, such as microcoils and NBCA glue-lipiodol mixture, were required in three patients to enhance complete occlusion of GR shunt or obliteration of competitive collateral vessels. Clinical success was defined as no variceal rebleeding and disappearance of gastric varix. Results All technical and clinical success–i.e., complete GR shunt occlusion and offending gastric varix embolization with immediate bleeding control–was achieved in all 9 patients. There was no procedure-related complication. All cases showed successful clinical outcome during mean follow up of 17 months (12–32 months), evidenced by imaging studies, endoscopy and clinical data. In 4 patients, mild worsening of esophageal varices or transient ascites was noted as portal hypertensive related change. Conclusion Emergent PARTO is technically feasible and safe, with acceptable mid-term clinical results, in treating active gastric varix bleeding. PMID:27189294

  13. Fat embolism syndrome

    PubMed Central

    George, Jacob; George, Reeba; Dixit, R.; Gupta, R. C.; Gupta, N.

    2013-01-01

    Fat embolism syndrome is an often overlooked cause of breathlessness in trauma wards. Presenting in a wide range of clinical signs of varying severity, fat embolism is usually diagnosed by a physician who keeps a high degree of suspicion. The clinical background, chronology of symptoms and corroborative laboratory findings are instrumental in a diagnosis of fat embolism syndrome. There are a few diagnostic criteria which are helpful in making a diagnosis of fat embolism syndrome. Management is mainly prevention of fat embolism syndrome, and organ supportive care. Except in fulminant fat embolism syndrome, the prognosis is usually good. PMID:23661916

  14. Long term follow-up of bifurcation aneurysms treated with braided stent assisted coiling and complex T- and Y- stent constructs.

    PubMed

    Cheung, Nicholas K; Chiu, Albert Hy; Cheung, Andrew; Wenderoth, Jason D

    2018-06-01

    Stent assisted coil embolization (SACE) of bifurcation aneurysms is challenging. Heterogeneous results have been achieved to date, but largely for laser cut stents. While braided stents offer multiple technical advantages, their long term efficacy has yet to be validated. To report the first long term 18 month results for the durability of bifurcation aneurysms treated with braided stents. Over a 4 year period, 59 consecutive patients with 60 bifurcation aneurysms underwent elective braided SACE across three Australian neurovascular centers. 17 of these aneurysms underwent T- or Y-shaped stent constructs. All patients had immediate, 6 month and 18 month clinical and radiological follow-up. Radiological assessment was made on modified Raymond-Roy occlusion scores while clinical assessment was based on the modified Rankin Scale. Subgroup analysis of 17 aneurysms treated with multi-stent constructs was conducted. 6 month follow-up data were available for 59 aneurysms and 18 month follow-up data for 58 aneurysms. Satisfactory aneurysm occlusion was achieved in 97% at inception and at 6 months, and 98% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Similar satisfactory results were achieved with the multi-stent construct cohort. Intraprocedural thromboembolic events were recorded in 5% and delayed events in 2%. Technical complications were found in 5%. All complication rate was 13%. Braided SACE was safe, efficacious, and durable at the long term 18 month follow-up, including for multi-stent constructs. Preliminary results indicate favorable clinical and radiological outcomes compared with laser cut stents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Coagulation abnormalities in pediatric and adult patients after sclerotherapy or embolization of vascular anomalies.

    PubMed

    Mason, K P; Neufeld, E J; Karian, V E; Zurakowski, D; Koka, B V; Burrows, P E

    2001-12-01

    The purpose of our study was to examine the coagulation status in patients with vascular anomalies who had undergone sclerotherapy or embolization. Ours was a prospective pilot study of 29 patients who had undergone sclerotherapy or embolization of large vascular anomalies. Fibrinogen, platelet, and d-dimer levels and prothrombin time were obtained before, immediately after, and on the day after the procedure. Five patients with venous malformations had positive d-dimer levels before the procedure. A subgroup analysis revealed a relationship between the type of agent used and the change in coagulation status. Specifically, a positive relationship was found between the use of dehydrated alcohol or sodium tetradecyl sulfate and a disruption in coagulation profiles as evidenced by a decrease in platelets and fibrinogen, an increase in prothrombin time, and a conversion from negative to positive d-dimers. In contrast, sclerotherapy or embolization with cyanoacrylic, polyvinyl alcohol foam particles, or platinum microcoils was not associated with coagulation disturbances. The coagulation disturbances that occur in response to dehydrated alcohol or sodium tetradecyl sulfate sclerotherapy or embolization could compromise the patient's clotting ability. Patients who receive dehydrated alcohol or sodium tetradecyl sulfate during a preoperative sclerotherapy or embolization may experience coagulation disturbances that could increase the risk of bleeding, thrombosis, or hematoma. This patient population may benefit from the use of glue, foam, or coils as a substitute for dehydrated alcohol or sodium tetradecyl sulfate.

  16. Is side-viewing endoscope assisted balloon dilatation better for corrosive gastric outlet obstruction?

    PubMed

    Katiyar, Prashant; Nijhawan, Sandeep; Saradava, Vimal; Nagaich, Neeraj; Gupta, Gaurav; Mathur, Amit; Nepalia, Subhash

    2013-11-01

    Endoscopic balloon dilatation (EBD) is an effective therapy for caustic-induced gastric outlet obstruction (GOO). Gaining access to the stricture site is the most important step. It is sometimes difficult to negotiate a balloon through the stricture with a front-viewing endoscope due to deformed anatomy of stomach. To overcome this technical difficulty, a side-viewing endoscope can be used. There is limited data regarding the use of side-viewing endoscopes in EBD. We here report on the short-term efficacy and safety of EBD in caustic-induced GOO. In technically difficult cases, a side-viewing endoscope was used for EBD and its efficacy and safety were assessed. The study included 25 patients with caustic-induced GOO. Patients underwent EBD using a through-the-scope balloon. Initial balloon dilatation was performed with a front-viewing endoscope. A side-viewing endoscope was used where negotiation across the stricture failed with a front-viewing endoscope. Dilatation was started at 8 mm diameter and was performed at 1-week intervals. The end point of dilatation was 15 mm diameter. In 18 patients successful balloon dilatation was possible with a front-viewing endoscope. A side-viewing endoscope was used in six patients as negotiation across the stricture was not possible with a front-viewing endoscope. In all six patients negotiation across the stricture followed by successful dilatation was successful with a side-viewing endoscope. Of the 25 patients included in this study, 24 (96%) achieved procedural success (18 with a front-viewing endoscope and 6 with a side-viewing endoscope) in 3-9 sessions. Our results show that EBD is a safe and effective option for caustic-induced GOO and in difficult cases a side-viewing endoscope can be used to achieve technical success.

  17. Computational fluid dynamics (CFD) using porous media modeling predicts recurrence after coiling of cerebral aneurysms

    PubMed Central

    Ishida, Fujimaro; Tsuji, Masanori; Furukawa, Kazuhiro; Shiba, Masato; Yasuda, Ryuta; Toma, Naoki; Sakaida, Hiroshi; Suzuki, Hidenori

    2017-01-01

    Objective This study aimed to predict recurrence after coil embolization of unruptured cerebral aneurysms with computational fluid dynamics (CFD) using porous media modeling (porous media CFD). Method A total of 37 unruptured cerebral aneurysms treated with coiling were analyzed using follow-up angiograms, simulated CFD prior to coiling (control CFD), and porous media CFD. Coiled aneurysms were classified into stable or recurrence groups according to follow-up angiogram findings. Morphological parameters, coil packing density, and hemodynamic variables were evaluated for their correlations with aneurysmal recurrence. We also calculated residual flow volumes (RFVs), a novel hemodynamic parameter used to quantify the residual aneurysm volume after simulated coiling, which has a mean fluid domain > 1.0 cm/s. Result Follow-up angiograms showed 24 aneurysms in the stable group and 13 in the recurrence group. Mann-Whitney U test demonstrated that maximum size, dome volume, neck width, neck area, and coil packing density were significantly different between the two groups (P < 0.05). Among the hemodynamic parameters, aneurysms in the recurrence group had significantly larger inflow and outflow areas in the control CFD and larger RFVs in the porous media CFD. Multivariate logistic regression analyses demonstrated that RFV was the only independently significant factor (odds ratio, 1.06; 95% confidence interval, 1.01–1.11; P = 0.016). Conclusion The study findings suggest that RFV collected under porous media modeling predicts the recurrence of coiled aneurysms. PMID:29284057

  18. Transcatheter Arterial Embolization for Upper Gastrointestinal Nonvariceal Hemorrhage: Is Empiric Embolization Warranted?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arrayeh, Elnasif; Fidelman, Nicholas, E-mail: nicholas.fidelman@ucsf.edu; Gordon, Roy L.

    Purpose: To determine whether transcatheter arterial embolization performed in the setting of active gastric or duodenal nonvariceal hemorrhage is efficacious when the bleeding source cannot be identified angiographically. Methods: Records of 115 adult patients who underwent visceral angiography for endoscopically documented gastric (50 patients) or duodenal (65 patients) nonvariceal hemorrhage were retrospectively reviewed. Patients were subdivided into three groups according to whether angiographic evidence of arterial hemorrhage was present and whether embolization was performed (group 1 = no abnormality, no embolization; group 2 = no abnormality, embolization performed [empiric embolization]; and group 3 = abnormality present, embolization performed). Thirty-day ratesmore » and duration of primary hemostasis and survival were compared.ResultsFor patients with gastric sources of hemorrhage, the rate of primary hemostasis at 30 days after embolization was greater when embolization was performed in the setting of a documented angiographic abnormality than when empiric embolization was performed (67% vs. 42%). The rate of primary hemostasis at 30 days after angiography was greater for patients with duodenal bleeding who either underwent empiric embolization (60%) or embolization in the setting of angiographically documented arterial hemorrhage (58%) compared with patients who only underwent diagnostic angiogram (33%). Patients with duodenal hemorrhage who underwent embolization were less likely to require additional invasive procedures to control rebleeding (p = 0.006). Conclusion: Empiric arterial embolization may be advantageous in patients with a duodenal source of hemorrhage but not in patients with gastric hemorrhage.« less

  19. Fat embolism syndrome.

    PubMed

    Stein, Paul D; Yaekoub, Abdo Y; Matta, Fadi; Kleerekoper, Michael

    2008-12-01

    To assess the incidence and risk factors for fat embolism syndrome. Data from the National Hospital Discharge Survey (NHDS) were analyzed using International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes. From 1979 through 2005 among 928,324,000 patients discharged from short-stay hospitals in the United States, 41,000 (0.004%) had fat embolism syndrome. Among 21,538,000 patients with an isolated fracture of the femur (any site), tibia, fibula, pelvis, ribs, humerus, radius, or ulna, 25,000 (0.12%) developed fat embolism syndrome. Patients with multiple fractures of the femur (excluding neck) more often had fat embolism syndrome than those with isolated fractures (1.29% versus 0.54%). The incidence of fat embolism syndrome was lower with isolated fractures of the tibia or fibula (0.30%) and even lower with isolated fractures of the neck of the femur (0.06%). The incidence of fat embolism was too low to calculate with isolated fractures of the pelvis, ribs, humerus, radius, or ulna. Nonorthopedic conditions rarely, if ever, were accompanied by fat embolism syndrome. The fat embolism syndrome was more frequent in men (relative risk 5.71). Children, aged 0 to 9 years rarely had fat embolism syndrome. The fat embolism syndrome most commonly affected patients aged 10 to 39 years. The incidence of the fat embolism syndrome depends on the bone involved, whether fractures are isolated or multiple, the age of the patient and the gender. It rarely occurs as a result of medical conditions.

  20. Initial Clinical Experience with an Endoluminal Spiral Prosthesis for Treating Complicated Venous Thrombosis and Preventing Pulmonary Embolism

    PubMed Central

    Jakob, H.; Oelert, H.; Schmiedt, W.; Teusch, P.; Iversen, S.; Hake, U.; Schild, H.; Maass, D.

    1989-01-01

    Fourteen patients with complicated venous thrombosis or recurrent pulmonary embolism were treated by implantation of an endoluminal spiral prosthesis subsequent to balloon angioplasty, surgical thrombectomy or embolectomy, a combination of these, or, in 2 cases, no other treatment. The patients were divided into 2 groups, based on their primary diagnosis and the purpose of the prosthesis. Group I included 8 patients with extensive iliofemoral or caval thrombosis, caused by congenital caval stenosis (1 case) or extravascular compression or retraction (7 cases); 7 of these patients had had previous operations, and the remaining patient had undergone thrombolysis, which failed. The current treatment consisted of balloon angioplasty and surgical thrombectomy or embolectomy, and implantation of an endoluminal spiral stent to prevent elastic recoil of the vessel. In 4 cases, an arteriovenous fistula was constructed and was taken down 3 months later; in 1 additional patient, a bilateral arteriovenous fistula was created. Group II comprised 6 patients with recurrent pulmonary embolism (4 cases), massive pulmonary embolism (1 case), or paradoxical bilateral carotid artery embolism (1 case). Four of these patients underwent surgical thrombectomy or embolectomy, while 2 had no treatment other than filter implantation. All 6 underwent transluminal implantation of a helix caval filter (a modification of the endoluminal spiral stent). All but 1 implantation was accomplished by means of either a transfemoral or a transjugular cutdown; the remaining implantation was performed transatrially after a pulmonary embolectomy. The only device-related complication was a retroperitoneal hematoma in Group I, resulting from perforation of the inferior vena cava by the guidewire during device implantation. This complication necessitated an emergency laparotomy and takedown of the arteriovenous fistula, which resulted in rethrombosis of the left iliofemoral vein. The other 7 stented veins were

  1. Physiologically-relevant measurements of flow through coils and stents: towards improved modeling of endovascular treatment of intracranial aneurysms

    NASA Astrophysics Data System (ADS)

    Barbour, Michael; Levitt, Michael; Geindreau, Christian; Rolland Du Roscoat, Sabine; Johnson, Luke; Chivukula, Keshav; Aliseda, Alberto

    2016-11-01

    The hemodynamic environment in cerebral aneurysms undergoing flow-diverting stent (FDS) or coil embolization treatment plays a critical role in long-term outcomes. Standard modeling approaches to endovascular coils and FDS simplify the complex geometry into a homogenous porous volume or surface through the addition of a Darcy-Brinkman pressure loss term in the momentum equation. The inertial and viscous loss coefficients are typically derived from published in vitro studies of pressure loss across FDS and coils placed in a straight tube, where the only fluid path is across the treatment - an unrealistic representation of treatment apposition in vivo. The pressure drop across FDS and coils in side branch aneurysms located on curved parent vessels is measured. Using PIV, the velocity at the aneurysm neck plane is reconstructed and used to determine loss coefficients for better models of endovascular coils or FDS that account for physiological placement and vessel curvature. These improved models are incorporated into CFD simulations and validated against in vitro model PIV velocity, as well as compared to microCT-based coil/stent-resolving CFD simulations of patient-specific treated aneurysm flow.

  2. Distal Embolization After Stenting of the Vertebral Artery: Diffusion-Weighted Magnetic Resonance Imaging Findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Canyigit, Murat; Arat, Anil; Cil, Barbaros E.

    2007-04-15

    Purpose. We retrospectively evaluated our experience with stenting of the vertebral artery in an effort to determine the risk of distal embolization associated with the procedure. Methods. Between June 2000 and May 2005, 35 patients with 38 stenting procedures for atherosclerotic disease of the vertebral origin in our institution were identified. The average age of the patients was 60.3 years (range 32-76 years). Sixteen of these patients (with 18 stents) had MR imaging of the brain with diffusion-weighted imaging and an apparent diffusion coefficient map within 2 days before and after procedure. Results. On seven of the 16 postprocedural diffusion-weightedmore » MR images, a total of 57 new hyperintensities were visible. All these lesions were focal in nature. One patient demonstrated a new diffusion-weighted imaging abnormality in the anterior circulation without MR evidence of posterior circulation ischemia. Six of 16 patients had a total of 25 new lesions in the vertebrobasilar circulation in postprocedural diffusion-weighted MR images. One patient in this group was excluded from the final analysis because the procedure was complicated by basilar rupture during tandem stent deployment in the basilar artery. Hence, new diffusion-weighted imaging abnormalities were noted in the vertebrobasilar territory in 5 of 15 patients after 17 stenting procedures, giving a 29% rate of diffusion-weighted imaging abnormalities per procedure. No patient with bilateral stenting had new diffusion-weighted imaging abnormalities. Conclusion. Stenting of stenoses of the vertebral artery origin may be associated with a significant risk of asymptomatic distal embolization. Angiography, placement of the guiding catheter, inflation of the stent balloon, and crossing the lesion with guidewires or balloon catheters may potentially cause distal embolization. Further studies to evaluate measures to increase the safety of vertebral artery stenting, such as the use of distal protection

  3. Use of a latest-generation vascular plug for peripheral vascular embolization with use of a diagnostic catheter: preliminary clinical experience.

    PubMed

    Mordasini, Pasquale; Szucs-Farkas, Zsolt; Do, Do-Dai; Gralla, Jan; Kettenbach, Joachim; Hoppe, Hanno

    2010-08-01

    The latest-generation Amplatzer vascular plug (AVP), the AVP 4, is designed for embolization of smaller vessels without a sheath or guiding catheter. This study evaluated the AVP 4 in peripheral vascular embolization. Embolization with the AVP 4 was attempted in 13 patients (11 men) for trauma (n = 7) and other indications (n = 6). Technical success rate, vascular bed, size of catheter, and number and size of AVP 4 devices were recorded. Embolization with the AVP 4 was successful in 10 of 13 patients (77%). In trauma patients (n = 7), embolization of the splenic artery (n = 4), lumbar artery (n = 2), and superior gluteal artery (n = 1) was performed. In other patients, preoperative embolization of the right portal vein (n = 1), a gastric varix after transjugular intrahepatic portosystemic shunt creation (n = 1), an aneurysm of the internal iliac artery (n = 1), and inferior mesenteric artery (IMA) embolization before aneurysm repair (n = 2) was performed. Sizes of the AVP 4 were 4 mm (n = 6), 6 mm (n = 5), and 8 mm (n = 1). In all patients, 4- and 5-F catheters with a 0.038-inch minimum inner lumen were used. In one patient, IMA embolization was attempted via a femoral approach but was unsuccessful as a result of repeated catheter tip dislocation because of acute angle; coils were used instead. Peripheral embolization with the AVP 4 was successful in the majority of patients. Future comparative study is necessary to evaluate this device's benefits over other embolization materials such as earlier-generation AVPs or microcoils. Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.

  4. Comparison of double-balloon and single-balloon enteroscope for therapeutic endoscopic retrograde cholangiography after Roux-en-Y small bowel surgery.

    PubMed

    De Koning, Michael; Moreels, Tom G

    2016-08-22

    Roux-en-Y reconstructive surgery excludes the biliopancreatic system from conventional endoscopic access. Balloon-assisted enteroscopy allows therapeutic endoscopic retrograde cholangiopancreatography (ERCP) in these patients, avoiding rescue surgery. The objective of the current study is to compare success and complication rate of double-balloon (DBE) and single-balloon enteroscope (SBE) to perform ERCP in Roux-en-Y patients. Seventy three Roux-en-Y patients with suspected biliary tract pathology underwent balloon-assisted enteroscopy in a tertiary-care center. Retrospective analysis of 95 consecutive therapeutic ERCP procedures was performed to define and compare success and complication rate of DBE and SBE. Male-female ratio was 28/45 with a mean age of 58 ± 2 years. 30 (32 %) procedures were performed with DBE and 65 (68 %) with SBE. Overall ERCP success rate was 73 % for DBE and 75 % for SBE (P = 0.831). Failure was due to inability to reach or cannulate the intact papilla or bilioenteric anastomosis. Success rate was significantly higher when performed at the bilioenteric anastomosis (80 % success in 56 procedures) or at the intact papilla in short-limb Roux-en-Y (80 % in 15 procedures) as compared to the intact papilla in long-limb (58 % in 24 procedures; P = 0.040). Adverse event rates were 10 % (DBE) and 8 % (SBE) (P = 0.707) and mostly dealt with conservatively. ERCP after Roux-en-Y altered small bowel anatomy is feasible and safe using both DBE and SBE. Both techniques are equally competent with high success rates and acceptable adverse events rates. ERCP at the level of the intact papilla in long limb Roux-en-Y is less successful as compared to short-limb or bilioenteric anastomosis.

  5. Japanese Balloon Program

    NASA Astrophysics Data System (ADS)

    Yoshida, Tetsuya; Fuke, Hideyuki; Shoji, Yasuhiro; Iijima, Issei; Izutsu, Naoki; Kato, Yoichi; Matsuzaka, Yukihiko; Mizuta, Eiichi; Sato, Takatoshi; Tamura, Keisuke; Saito, Yoshitaka; Kakehashi, Yuya

    2012-07-01

    Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency conducts domestic balloon campaigns at Taiki Aerospace Research Field (TARF) in Hokkaido since 2008. The ballooning at TARF becomes stable after four year operation. Because the field faces to the Pacific Ocean, heavy balloons and payloads can be launched safely using a very unique sliding launcher. Recoveries at the inshore along the Tokachi coast can be done very quickly and smoothly. Unfortunately, flight opportunities are recently limited due to unfriendly weather condition. Unstable Jet stream also prevents us to have so-called `boomerang flight' to achieve long flight duration more than several hours. Six balloon-borne experiments were carried out in 2010 and 2011. Three of them were demonstrations of challenges of space engineering, two were in-situ atmospheric observation, and one was the technical flight of new high-resolution γ-ray telescope. In addition to these flights, we carried out two launches for next generation balloons: one for Tawara-shaped superpressure balloon and the other for ultra-thin high-altitude balloon. In this paper, recent activities of the Japanese scientific balloon program will be introduced. On-going development of the balloon system will also be presented.

  6. Nonhuman primate models of focal cerebral ischemia

    PubMed Central

    Fan, Jingjing; Li, Yi; Fu, Xinyu; Li, Lijuan; Hao, Xiaoting; Li, Shasha

    2017-01-01

    Rodents have been widely used in the production of cerebral ischemia models. However, successful therapies have been proven on experimental rodent stroke model, and they have often failed to be effective when tested clinically. Therefore, nonhuman primates were recommended as the ideal alternatives, owing to their similarities with the human cerebrovascular system, brain metabolism, grey to white matter ratio and even their rich behavioral repertoire. The present review is a thorough summary of ten methods that establish nonhuman primate models of focal cerebral ischemia; electrocoagulation, endothelin-1-induced occlusion, microvascular clip occlusion, autologous blood clot embolization, balloon inflation, microcatheter embolization, coil embolization, surgical suture embolization, suture, and photochemical induction methods. This review addresses the advantages and disadvantages of each method, as well as precautions for each model, compared nonhuman primates with rodents, different species of nonhuman primates and different modeling methods. Finally it discusses various factors that need to be considered when modelling and the method of evaluation after modelling. These are critical for understanding their respective strengths and weaknesses and underlie the selection of the optimum model. PMID:28400817

  7. Transcatheter Embolization of a Renal Artery Aneurysm Using Ethylene Vinyl Alcohol Copolymer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rautio, Riitta, E-mail: riitta.rautio@tyks.fi; Haapanen, Arto

    2007-04-15

    Our aim was to treat a clinically silent renal artery aneurysm. The patient was a 76-year-old man with elevated prostate-specific antigen and prostata biopsies with a gradus II-III adenocarcinoma who was incidentally found to have an aneurysm in his right renal artery. We performed a successful transcatheter embolization of the aneurysm using ethylene vinyl alcohol copolymer (Onyx). To avoid migration of the liquid material into the parent artery, a balloon was inflated in the orifice of the neck of the aneurysm while the liquid was injected. Five-month follow-up computed tomography (CT) imaging confirmed total occlusion of the aneurysm.

  8. Clinical Results and Problems of Percutaneous Transluminal Angioplasty and Stenting for Extracranial Internal Carotid Stenoses

    PubMed Central

    Tsuura, M.; Terada, T.; Masuo, O.; Matsumoto, H.; Itakura, T.; Hyoutani, G.; Nakamura, Y.; Moriwaki, H.; Hayashi, S.

    2001-01-01

    Summary 110 patients with extracranial ICA stenosis were treated by PTA or stenting. In 21 of 55 cases of only PTA and in 40 of 55 cases of stenting, we used our blocking balloon systems to prevent distal embolism. The morbidity and the mortality rates were 5.4% and 0%, respectively. There was only one embolic complication in cases of PTA or stenting where blocking balloon systems were used. In contrast, distal embolism occurred in 3 of 34 cases of PTA without blocking balloon systems (one symptomatic case) and in 4 of 15 cases of stenting without blocking balloon systems (3 symptomatic cases). Our blocking balloon catheter system is a useful device to reduce the risk of symptomatic distal embolism. PMID:20663375

  9. Ruptured renal arteriovenous malformation successfully treated by catheter embolization: a case report.

    PubMed

    Takeuchi, Nobuhiro; Nomura, Yusuke

    2014-01-09

    Renal arteriovenous fistula (RAVF) is a comparatively rare malformation. Here, we report a case of ruptured RAVF that was successfully treated by catheter embolization. An 89-year-old female was transferred to our institution with massive gross hematuria in March 2011. Plain abdominal computed tomography (CT) revealed dilated left renal pelvis with high-density contents. Hematoma was suspected. Subsequent plain abdominal magnetic resonance imaging revealed left hydronephrosis and blood retention in the dilated left renal pelvis. No renal or ureteral cancer was evident. Hematuria was conservatively treated using hemostatic agents but hematuria persisted. Repeated urinary cytology revealed no malignant cells. On day 9, the patient went into septic and/or hemorrhagic shock. Fluid and catecholamine infusion, blood transfusion, and antibacterial drugs were rapidly initiated, and the patient's general condition gradually improved. Contrast-enhanced abdominal CT revealed marked expansion of the hematoma in the renal pelvis and microaneurysms in the segmental arteries of the left kidney. Inflammation improved, and a left double-J stent was inserted. Selective renal angiography revealed RAVF with microaneurysms in the left segmental arteries; therefore, catheter embolization using metallic coils was performed, which resolved hematuria. We report a case of ruptured renal arteriovenous malformation, which was successfully treated by catheter embolization.

  10. An unusual complication of a "blind" femoral embolectomy.

    PubMed

    Karkos, Christos D; Karamanos, Dimitrios G; Papadimitriou, Dimitrios N; Demiropoulos, Filippos; Zambas, Neophytos; Gerassimidis, Thomas S

    2010-08-01

    Iatrogenic pseudoaneurysms after femoral embolectomy are unusual and have been described in the peroneal, posterior tibial, and popliteal arteries. We present an unusual case of such a pseudoaneurysm originating from a medial superior genicular collateral vessel that was coming off the proximal popliteal artery at an acute angle. It is likely that the embolectomy catheter had accidentally entered this branch, which ruptured when the balloon was inflated. Transcatheter coil embolization resulted in successful thrombosis of the pseudoaneurysm. Copyright 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  11. Endolymphatic Ethiodized Oil Intranodal Lymphangiography and Cyanoacrylate Glue Embolization for the Treatment of Postoperative Lymphatic Leak After Robot-Assisted Laparoscopic Pelvic Resection.

    PubMed

    Hill, Hannah; Srinivasa, Ravi N; Gemmete, Joseph J; Hage, Anthony; Bundy, Jacob; Chick, Jeffrey Forris Beecham

    2018-01-01

    Purpose: To report the approach, technical success, clinical outcomes, complications, and follow-up of ethiodized oil intranodal lymphangiography with cyanoacrylate glue embolization for the treatment of lymphatic leak after robot-assisted laparoscopic pelvic resection. Materials and Methods: Four men with mean age 68.7 ± 14.3 years were treated with ethiodized oil intranodal lymphangiography with cyanoacrylate embolization for postoperative lymphatic leak. Patients underwent either (1) cystoprostatectomy with ileal conduit and bilateral extensive pelvic lymph node dissection for muscle-invasive urothelial carcinoma and presented with postoperative lymphatic ascites ( n  = 2) or (2) prostatectomy with bilateral standard pelvic lymph node dissection for prostate carcinoma and presented with postoperative pelvic lymphoceles ( n  = 2). Intranodal lymphangiography and embolization procedural details, technical success, clinical outcomes, and follow-up were recorded. Results: In four patients, a total of six ethiodized oil intranodal lymphangiograms were performed, two procedures being repeated interventions. Inguinal lymph node catheterization and ethiodized oil lymphangiography was technically effective in all procedures. A mean of 5.2 ± 2.0 mL of ethiodized oil was used for lymphatic opacification. Cyanoacrylate was diluted to 24.2% with ethiodized oil and 0.44 mL of cyanoacrylate was instilled during first time interventions. On repeat procedures, cyanoacrylate was diluted to 51.7%, and 0.52 mL was instilled. The primary clinical success rate was 50% ( n  = 2/4). Clinical success was achieved in all patients after two interventions ( n  = 4; 100%). No complications were reported at mean follow-up of 134.7 ± 79.2 days (range: 59-248 days). Conclusion: Ethiodized oil intranodal lymphangiography with direct cyanoacrylate glue embolization is a minimally invasive treatment option for lymphatic leak after pelvic resection.

  12. Improved techniques for double-balloon-enteroscopy-assisted endoscopic retrograde cholangiopancreatography

    PubMed Central

    Osoegawa, Takashi; Motomura, Yasuaki; Akahoshi, Kazuya; Higuchi, Naomi; Tanaka, Yoshimasa; Hisano, Terumasa; Itaba, Souichi; Gibo, Junya; Yamada, Mariko; Kubokawa, Masaru; Sumida, Yorinobu; Akiho, Hirotada; Ihara, Eikichi; Nakamura, Kazuhiko

    2012-01-01

    AIM: To investigate the clinical outcome of double balloon enteroscopy (DBE)-assisted endoscopic retrograde cholangiopancreatography (DB-ERCP) in patients with altered gastrointestinal anatomy. METHODS: Between September 2006 and April 2011, 47 procedures of DB-ERCP were performed in 28 patients with a Roux-en-Y total gastrectomy (n = 11), Billroth II gastrectomy (n = 15), or Roux-en-Y anastomosis with hepaticojejunostomy (n = 2). DB-ERCP was performed using a short-type DBE combined with several technical innovations such as using an endoscope attachment, marking by submucosal tattooing, selectively applying contrast medium, and CO2 insufflations. RESULTS: The papilla of Vater or hepaticojejunostomy site was reached in its entirety with a 96% success rate (45/47 procedures). There were no significant differences in the success rate of reaching the blind end with a DBE among Roux-en-Y total gastrectomy (96%), Billroth II reconstruction (94%), or pancreatoduodenectomy (100%), respectively (P = 0.91). The total successful rate of cannulation and contrast enhancement of the target bile duct in patients whom the blind end was reached with a DBE was 40/45 procedures (89%). Again, there were no significant differences in the success rate of cannulation and contrast enhancement of the target bile duct with a DBE among Roux-en-Y total gastrectomy (88 %), Billroth II reconstruction (89%), or pancreatoduodenectomy (100%), respectively (P = 0.67). Treatment was achieved in all 40 procedures (100%) in patients whom the contrast enhancement of the bile duct was successful. Common endoscopic treatments were endoscopic biliary drainage (24 procedures) and extraction of stones (14 procedures). Biliary drainage was done by placement of plastic stents. Stones extraction was done by lithotomy with the mechanical lithotripter followed by extraction with a basket or by the balloon pull-through method. Endoscopic sphincterotomy was performed in 14 procedures with a needle precutting

  13. Preoperative catheter spinal angiography and embolization of cervical spinal tumors: Outcomes from a single center

    PubMed Central

    Leng, Lewis Z; Kimball, David; Marcus, Joshua; Knopman, Jared; Laufer, Ilya; Bilsky, Mark; Gobin, Y Pierre

    2016-01-01

    Objective The existing literature regarding preoperative cervical spinal tumor embolization is sparse, with few discussions on the indications, risks, and best techniques. We present our experience with the preoperative endovascular management of hypervascular cervical spinal tumors. Methods We performed a retrospective review of all patients who underwent preoperative spinal angiography (regardless of whether tumor embolization was performed) at our institution (from 2002 to 2012) for primary and metastatic cervical spinal tumors. Tumor vascularity was graded from 0 (tumor blush equal to the normal adjacent vertebral body) to 3 (intense tumor blush with arteriovenous shunting). Tumors were considered “hypervascular” if they had a tumor vascular grade from 1 to 3. Embolic materials included particles, liquid embolics, and detachable coils. The main embolization technique was superselective catheterization of an arterial tumor feeder followed by injection of embolic material. This technique could be used alone or supplemented with occlusion of dangerous anastomoses of the vertebral artery as needed to prevent inadvertent embolization of the vertebrobasilar system. In cases when superselective catheterization of the tumoral feeder was not feasible, embolization was performed from a proximal catheter position after occlusion of branches supplying areas other than the tumor (“flow diversion”). Results A total of 47 patients with 49 cervical spinal tumors were included in this study. Of the 49 total tumors, 41 demonstrated increased vascularity (vascularity score > 0). The most common tumor pathology in our series was renal cell carcinoma (RCC) (N = 16; 32.7% of all tumors) followed by thyroid carcinoma (N = 7; 14.3% of all tumors). Tumor embolization was undertaken in 25 hypervascular tumors resulting in complete, near-complete, and partial embolization in 36.0% (N = 9), 44.0% (N = 11), and 20.0% (N = 5) of embolized tumors, respectively

  14. Spiral assisted ERCP is equivalent to single balloon assisted ERCP in patients with Roux-en-Y anatomy.

    PubMed

    Lennon, Anne Marie; Kapoor, Sumit; Khashab, Mouen; Corless, Erin; Amateau, Stuart; Dunbar, Kerry; Chandrasekhara, Vinay; Singh, Vikesh; Okolo, Patrick I

    2012-05-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is often unsuccessful in patients with Roux-en-Y anatomy. Augmented enteroscopy allows deep insertion into the small bowel and can be useful in patients with Roux-en-Y anatomy. The aim of this study was to compare single balloon assisted ERCP (SBE-ERCP) and spiral assisted ERCP (SE-ERCP) in patients with Roux-en-Y anatomy in terms of diagnostic and therapeutic yield, procedure time, and complications. This is a retrospective cohort study of consecutive patients with Roux-en-Y anatomy who underwent SBE-ERCP or SE-ERCP between October 2007 and March 2011. Diagnostic yield was defined as successful duct cannulation. Therapeutic yield was defined as the ability to successfully carry out endoscopic therapy in those cannulated. Procedure time and complications were assessed. Thirty-four consecutive patients with Roux-en-Y anatomy underwent 54 ERCP procedures. The overall diagnostic yield was 44.4% with no significant difference between the diagnostic yield of SBE-ERCP (48.3%) and SE-ERCP (40%). The diagnostic yield was lower in patients with gastric by-pass (38.9%) compared with other types of Roux-en-Y anatomy (47.2%) but this was not statistically significant (P = 0.772). The overall therapeutic yield was 93.8%, with a therapeutic yield of 100% for SBE-ERCP and 87.5% for SE-ERCP (P = 1.0). There was one perforation during SBE-ERCP, giving a complication rate of 3.5%. The mean procedure time did not differ between the two techniques. Diagnostic and therapeutic yields are similar with SBE-ERCP and SE-ERCP in patients with Roux-en-Y anatomy with no significant difference in procedure time or complication rates.

  15. Intraoperative direct puncture and embolization (IOPE) using a glue material for spinal cord arteriovenous fistula: a case report.

    PubMed

    Shin, Hong Kyung; Suh, Dae Chul; Jeon, Sang Ryong

    2015-05-01

    Spinal arteriovenous fistula (AVF) is treated by embolization or surgery. However, transarterial embolization or surgery is difficult in rare cases when the fistula site is very complicated to access especially as in fistular nidus supplied by posterior and anterior spinal artery. We present the case which was treated with intraoperative direct puncture and embolization (IOPE) using glue material, since the usual transarterial or transvenous neurointerventional approach was difficult to embolize the AVF. A 36-year-old woman presented with progressive leg weakness and pain after a 20-year history of lower back pain. She had pelvic and spinal AVF combined with arteriovenous malformation (AVM). Despite prior treatment of the pelvic lesion with radiotherapy and coil embolization, the spinal lesion persisted and caused repeated subarachnoid hemorrhages. A spinal angiogram revealed a tortuous and long feeder of the AVF which had growing venous sac, as well as AVM. Two embolization trials failed because of the long tortuosity and associated anterior spinal artery. Four months later, drastic leg weakness and pain occurred, and IOPE was performed using a glue material. The subsequent recovery of the patient was rapid. One month later, the use of a strong opioid could be discontinued, and the patient could walk with aid. A follow-up spinal angiogram revealed that the venous sac of the AVF had disappeared. In spinal AVF which is not feasible to access by usual intervention approach and to dissect surgically, IOPE with glue material can be considered for the treatment.

  16. Postpartum Hemorrhage Resulting from Pelvic Pseudoaneurysm: A Retrospective Analysis of 588 Consecutive Cases Treated by Arterial Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr; Soyer, Philippe, E-mail: philippe.soyer@lrb.aphp.fr; Subhani, Aqeel, E-mail: drsubhani07@gmail.com

    Objective: This study was designed to determine the incidence of arterial pseudoaneurysm in patients presenting with postpartum hemorrhage (PPH), to analyze the angiographic characteristics of pseudoaneurysms that cause PPH, and to evaluate the effectiveness of pelvic arterial embolization for the treatment of this condition.Study designEighteen women with pelvic arterial pseudoaneurysm were retrieved from a series of 588 consecutive patients with PPH treated by arterial embolization. Clinical files, angiographic examinations, and procedure details were reviewed. Results: The incidence of pseudoaneurysm was 3.06 % (18/588; 95 % confidence interval (CI): 1.82-4.8 %). A total of 20 pseudoaneurysms were found; 15/20 (75 %)more » were located on the uterine arteries. Angiography revealed extravasation of contrast material from pseudoaneurysm indicating rupture in 9 of 18 (50 %) patients. Arterial embolization was performed using gelatin sponge alone in 12 of 18 (67 %) patients or in association with metallic coils in 5 of 18 (28 %) patients or n-butyl-2-cyanoacrylate in 1 of 18 (6 %) patients. Arterial embolization allowed controlling the bleeding in all patients after one or two embolization sessions in 17 of 18 (94 %) and 1 of 18 patients (6 %) respectively, without complications, obviating the need for further surgery. Conclusions: Pseudoaneurysm is rarely associated with PPH. Arterial embolization is an effective and safe procedure for the treatment of PPH due to uterine or vaginal artery pseudoaneurysm. Our results suggest that gelatin sponge is effective for the treatment of ruptured pseudoaneurysms, although we agree that our series does not contain sufficient material to allow drawing definitive conclusions with respect to the most effective embolic material.« less

  17. Balloons and Science Kit.

    ERIC Educational Resources Information Center

    Balloon Council, Washington, DC.

    This document provides background information on balloons including: (1) the history of balloons; (2) balloon manufacturing; (3) biodegradability; (4) the fate of latex balloons; and (5) the effect of balloons on the rainforest and sea mammals. Also included as part of this instructional kit are four fun experiments that allow students to…

  18. Genome-Wide Identification of Arabidopsis Coiled-Coil Proteins and Establishment of the ARABI-COIL Database1

    PubMed Central

    Rose, Annkatrin; Manikantan, Sankaraganesh; Schraegle, Shannon J.; Maloy, Michael A.; Stahlberg, Eric A.; Meier, Iris

    2004-01-01

    Increasing evidence demonstrates the importance of long coiled-coil proteins for the spatial organization of cellular processes. Although several protein classes with long coiled-coil domains have been studied in animals and yeast, our knowledge about plant long coiled-coil proteins is very limited. The repeat nature of the coiled-coil sequence motif often prevents the simple identification of homologs of animal coiled-coil proteins by generic sequence similarity searches. As a consequence, counterparts of many animal proteins with long coiled-coil domains, like lamins, golgins, or microtubule organization center components, have not been identified yet in plants. Here, all Arabidopsis proteins predicted to contain long stretches of coiled-coil domains were identified by applying the algorithm MultiCoil to a genome-wide screen. A searchable protein database, ARABI-COIL (http://www.coiled-coil.org/arabidopsis), was established that integrates information on number, size, and position of predicted coiled-coil domains with subcellular localization signals, transmembrane domains, and available functional annotations. ARABI-COIL serves as a tool to sort and browse Arabidopsis long coiled-coil proteins to facilitate the identification and selection of candidate proteins of potential interest for specific research areas. Using the database, candidate proteins were identified for Arabidopsis membrane-bound, nuclear, and organellar long coiled-coil proteins. PMID:15020757

  19. Liquid Embolic Agents for Endovascular Embolization: Evaluation of an Established (Onyx) and a Novel (PHIL) Embolic Agent in an In Vitro AVM Model.

    PubMed

    Vollherbst, D F; Sommer, C M; Ulfert, C; Pfaff, J; Bendszus, M; Möhlenbruch, M A

    2017-07-01

    Embolization plays a key role in the treatment of arteriovenous malformations. The aim of this study was to evaluate an established (Onyx) and a novel (precipitating hydrophobic injectable liquid [PHIL]) liquid embolic agent in an in vitro AVM model. An AVM model was integrated into a circuit system. The artificial nidus (subdivided into 28 honeycomb-like sections) was embolized with Onyx 18 (group Onyx; n = 8) or PHIL 25 (group PHIL; n = 8) with different pause times between the injections (30 and 60 seconds, n = 4 per study group) by using a 1.3F microcatheter. Procedure times, number of injections, embolization success (defined as the number of filled sections of the artificial nidus), volume of embolic agent, and frequency and extent of reflux and draining vein embolization were assessed. Embolization success was comparable between Onyx and PHIL. Shorter pause times resulted in a significantly higher embolization success for PHIL (median embolization score, 28 versus 18; P = .011). Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization (median volume per section of the artificial nidus, 15.5 versus 3.6 μL; P < .001). While the embolization success was comparable for Onyx and PHIL, pause time had a considerable effect on the embolization success in an in vitro AVM model. Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization. © 2017 by American Journal of Neuroradiology.

  20. Gastric ulcer bleeding from a variant left gastric artery accompanied by congenital absence of the splenic artery successfully treated with coil embolization: a case report and review of the literature.

    PubMed

    Namikawa, Masashi; Kakizaki, Satoru; Takakusaki, Satoshi; Saito, Shuichi; Yata, Yutaka; Mori, Masatomo

    2011-12-01

    Endoscopic hemostasis is a useful treatment modality for gastric ulcer bleeding. However, it is sometimes difficult to achieve hemostasis in cases with arterial bleeding, especially those complicated with vascular abnormalities. We describe a case with gastric ulcer bleeding from a variant left gastric artery accompanied by congenital absence of the splenic artery. A 50-year-old female was admitted to our hospital with dizziness and tarry stools. Upper gastrointestinal endoscopy revealed bleeding from a gastric ulcer, and endoscopic hemostasis by endoscopic clipping was carried out. Computed tomography and abdominal angiography revealed the variant left gastric artery running below the gastric ulcer. In spite of endoscopic hemostasis and medication, re-bleeding from the gastric ulcer occurred. A transcatheter coil embolization for the variant left gastric artery was performed and successfully achieved hemostasis. This case was accompanied by congenital absence of the splenic artery, which is an extremely rare condition. We herein describe this rare case and review previously reported cases.

  1. Molecular basis of coiled-coil oligomerization-state specificity.

    PubMed

    Ciani, Barbara; Bjelic, Saša; Honnappa, Srinivas; Jawhari, Hatim; Jaussi, Rolf; Payapilly, Aishwarya; Jowitt, Thomas; Steinmetz, Michel O; Kammerer, Richard A

    2010-11-16

    Coiled coils are extensively and successfully used nowadays to rationally design multistranded structures for applications, including basic research, biotechnology, nanotechnology, materials science, and medicine. The wide range of applications as well as the important functions these structures play in almost all biological processes highlight the need for a detailed understanding of the factors that control coiled-coil folding and oligomerization. Here, we address the important and unresolved question why the presence of particular oligomerization-state determinants within a coiled coil does frequently not correlate with its topology. We found an unexpected, general link between coiled-coil oligomerization-state specificity and trigger sequences, elements that are indispensable for coiled-coil formation. By using the archetype coiled-coil domain of the yeast transcriptional activator GCN4 as a model system, we show that well-established trimer-specific oligomerization-state determinants switch the peptide's topology from a dimer to a trimer only when inserted into the trigger sequence. We successfully confirmed our results in two other, unrelated coiled-coil dimers, ATF1 and cortexillin-1. We furthermore show that multiple topology determinants can coexist in the same trigger sequence, revealing a delicate balance of the resulting oligomerization state by position-dependent forces. Our experimental results should significantly improve the prediction of the oligomerization state of coiled coils. They therefore should have major implications for the rational design of coiled coils and consequently many applications using these popular oligomerization domains.

  2. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    NASA Astrophysics Data System (ADS)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  3. GHOST balloons around Antarctica

    NASA Technical Reports Server (NTRS)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  4. Rupture during coiling of intracranial aneurysms: Predictors and clinical outcome.

    PubMed

    Kocur, Damian; Przybyłko, Nikodem; Bażowski, Piotr; Baron, Jan

    2018-02-01

    The intraprocedural aneurysm rupture (IPR) is one of the most feared adverse effect associated with the coil embolization therapy. The aim of the study was to identify predisposing factors for IPR, as well as to define patient groups with worse clinical outcome following IPR. From February 2008 to March 2015, 273 consecutive patients were treated at our institution via endovascular coil embolization. Patient medical records were reviewed with emphasis on procedure description, potential risk factors and clinical outcomes related to IPR. The IPR occurred in 14 (5.13%) cases. Multivariate logistic regression models were used to determine independent predictors of IPR. Clinical outcome was analyzed using the Glasgow Outcome Scale (GOS). Multivariate analysis showed that aneurysm location at posterior communicating artery is an independent risk factor for IPR (p = 0.035; OR 3.5; 95%CI 1.09-11.26). The frequencies of favorable disability (GOS 4-5), severe disability (GOS 2-3), and mortality (GOS 1) between patients with IPR and without IPR were significantly different in the general study population (p < 0.001, p < 0.001 and p = 0.023, respectively) and in patients with previously unruptured aneurysms (p < 0.001, p = 0.006 and p = 0.003, respectively) but not in patients with previously ruptured aneurysms (p = 0.187, p = 0.089 and p = 1.0, respectively). Posterior communicating artery aneurysm location is an independent predictor for IPR. IPR is associated with a significant clinical deterioration in a subgroup of patients with previously unruptured aneurysms, but not in patients with ruptured aneurysms. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. The structure of the GemC1 coiled coil and its interaction with the Geminin family of coiled-coil proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caillat, Christophe; Fish, Alexander; Pefani, Dafni-Eleftheria

    The GemC1 coiled-coil structure has subtle differences compared with its homologues Geminin and Idas. Co-expression experiments in cells and biophysical stability analysis of the Geminin-family coiled coils suggest that the GemC1 coiled coil alone is unstable. GemC1, together with Idas and Geminin, an important regulator of DNA-replication licensing and differentiation decisions, constitute a superfamily sharing a homologous central coiled-coil domain. To better understand this family of proteins, the crystal structure of a GemC1 coiled-coil domain variant engineered for better solubility was determined to 2.2 Å resolution. GemC1 shows a less typical coiled coil compared with the Geminin homodimer and themore » Geminin–Idas heterodimer structures. It is also shown that both in vitro and in cells GemC1 interacts with Geminin through its coiled-coil domain, forming a heterodimer that is more stable that the GemC1 homodimer. Comparative analysis of the thermal stability of all of the possible superfamily complexes, using circular dichroism to follow the unfolding of the entire helix of the coiled coil, or intrinsic tryptophan fluorescence of a unique conserved N-terminal tryptophan, shows that the unfolding of the coiled coil is likely to take place from the C-terminus towards the N-terminus. It is also shown that homodimers show a single-state unfolding, while heterodimers show a two-state unfolding, suggesting that the dimer first falls apart and the helices then unfold according to the stability of each protein. The findings argue that Geminin-family members form homodimers and heterodimers between them, and this ability is likely to be important for modulating their function in cycling and differentiating cells.« less

  6. [Paradoxical brain embolism mediated through a pulmonary arteriovenous malformation with hereditary hemorrhagic telangiectasia in a Japanese patient].

    PubMed

    Takeda, June; Todo, Kenichi; Yamamoto, Shiro; Yamagami, Hiroshi; Kawamoto, Michi; Kohara, Nobuo

    2012-01-01

    We report a case of paradoxical brain embolism mediated through a pulmonary arteriovenous malformation (PAVM) with hereditary hemorrhagic telangiectasia (HHT). A 25-year-old right handed man was admitted to our hospital after sudden headache and visual field abnormality. In neurologic examinations, he had left superior-quadrantanopsia. Laboratory findings showed iron deficiency anemia. Diffusion weighted images disclosed a high-signal-intensity area in the right occipito-temporal lobe, and intraarterial digital subtraction cerebral angiography revealed occlusion of the right posterior cerebral artery. Transesophageal echocardiography revealed continuous right-to-left shunt. We confirmed his history of spontaneous recurrent epistaxis and the first-degree relatives with epistaxis or PAVM. A contrast enhanced CT scan of the chest revealed a PAVM. The diagnosis of paradoxical brain embolism mediated through the PAVM with HHT was, thus, established. The PAVM was occluded by using embolization coils successfully. In Asian countries, the prevalence of PAVM with HHT is thought to be lower than in European countries. We should carefully take medical and family histories, especially epistaxis, in a young stroke patient.

  7. Experimental measurement of coil-rod-coil block copolymer tracer diffusion through entangled coil homopolymers

    PubMed Central

    Wang, Muzhou; Timachova, Ksenia; Olsen, Bradley D.

    2014-01-01

    The diffusion of coil-rod-coil triblock copolymers in entangled coil homopolymers is experimentally measured and demonstrated to be significantly slower than rod or coil homopolymers of the same molecular weight. A model coil-rod-coil triblock was prepared by expressing rodlike alanine-rich α-helical polypeptides in E. coli and conjugating coillike poly(ethylene oxide) (PEO) to both ends to form coil-rod-coil triblock copolymers. Tracer diffusion through entangled PEO homopolymer melts was measured using forced Rayleigh scattering at various rod lengths, coil molecular weights, and coil homopolymer concentrations. For rod lengths, L, that are close to the entanglementh length, a, the ratio between triblock diffusivity and coil homopolymer diffusivity decreases monotonically and is only a function of L/a, in quantitative agreement with previous simulation results. For large rod lengths, diffusion follows an arm retraction scaling, which is also consistent with previous theoretical predictions. These experimental results support the key predictions of theory and simulation, suggesting that the mismatch in curvature between rod and coil entanglement tubes leads to the observed diffusional slowing. PMID:25484454

  8. A periodic table of coiled-coil protein structures.

    PubMed

    Moutevelis, Efrosini; Woolfson, Derek N

    2009-01-23

    Coiled coils are protein structure domains with two or more alpha-helices packed together via interlacing of side chains known as knob-into-hole packing. We analysed and classified a large set of coiled-coil structures using a combination of automated and manual methods. This led to a systematic classification that we termed a "periodic table of coiled coils," which we have made available at http://coiledcoils.chm.bris.ac.uk/ccplus/search/periodic_table. In this table, coiled-coil assemblies are arranged in columns with increasing numbers of alpha-helices and in rows of increased complexity. The table provides a framework for understanding possibilities in and limits on coiled-coil structures and a basis for future prediction, engineering and design studies.

  9. Recanalization after successful occlusion by transcatheter arterial embolization with N-butyl cyanoacrylate for traumatic splenic artery injury.

    PubMed

    Ishikawa, Masaki; Kakizawa, Hideaki; Yamasaki, Wataru; Date, Syuji; Hieda, Masashi; Kajiwara, Kenji; Awai, Kazuo

    2011-12-01

    A 70-year-old male with advanced pancreatic cancer went into shock after sustaining a traumatic abdominal injury. Computed tomography (CT) showed a hematoma with extravasation around the pancreas and hemorrhagic ascites. After direct catheterization failed due to angiospasm, the ruptured splenic artery was successfully occluded by transcatheter arterial embolization (TAE) using an N-butyl cyanoacrylate (NBCA)-lipiodol mixture and the patient recovered from shock without complications. A follow-up CT obtained 20 days later showed a recurrent splenic artery pseudoaneurysm without extravasation. A repeat angiogram demonstrated recanalization of the splenic artery and pseudoaneurysm via antegrade. We embolized the recanalized pseudoaneurysm using metallic coils for isolation. Our experience indicates that adequate concentration and volume of the NBCA-lipiodol mixture should be considered depending on the vascular spasm in a patient with hypovolemic shock.

  10. Removal of large hydatid cysts with balloon-assisted modification of Dowling's method: technical report.

    PubMed

    Ulutas, Murat; Cinar, Kadir; Secer, Mehmet

    2015-07-01

    Delivery of hydatid cysts, especially large ones, without rupture is very important and there is still no 100% successful method. After the hydatid cyst was reached, starting near the surface working around the cyst toward the base, a Foley probe was advanced and, in the region of desired dissection, the balloon of the Foley probe was inflated, and adhesion bands were freed to allow dissection. We believe our balloon-aided dissection technique is a method that increases the chances of delivering hydatid cysts, with no calcification and secondary infection, without rupture.

  11. Ballooning Comes of Age: Make Your Own Balloon.

    ERIC Educational Resources Information Center

    Eckford, Jim

    1983-01-01

    Provides instructions for building a working model of a hot-air balloon, offering suggestions for a successful flight. Indicates that children can be involved in the projects, for example, by filling in colors in the panels of a balloon drawing. (JN)

  12. Single Balloon Enteroscopy-Assisted Endoscopic Retrograde Cholangiopancreatography in Patients Who Underwent a Gastrectomy with Roux-en-Y Anastomosis: Six Cases from a Single Center.

    PubMed

    Soh, Jae Seung; Yang, Dong-Hoon; Lee, Sang Soo; Lee, Seohyun; Bae, Jungho; Byeon, Jeong-Sik; Myung, Seung-Jae; Yang, Suk-Kyun

    2015-09-01

    Patients with altered anatomy such as a Roux-en-Y anastomosis often present with various pancreaticobiliary problems requiring therapeutic intervention. However, a conventional endoscopic approach to the papilla is very difficult owing to the long afferent limb and acute angle of a Roux-en-Y anastomosis. Balloon-assisted enteroscopy can be used for endoscopic retrograde cholangiopancreatography (ERCP) in patients with altered anatomy. We experienced six cases of Roux-en-Y anastomosis with biliary problems, and attempted ERCP using single balloon enteroscopy (SBE). SBE insertion followed by replacement with a conventional endoscope was attempted in five of six patients. The papilla was successfully approached using SBE in all cases. However, therapeutic intervention was completed in only three cases because of poor maneuverability caused by postoperative adhesion. We conclude that in patients with Roux-en-Y anastomosis, the ampulla can be readily accessed with SBE, but longer dedicated accessories are necessary to improve this therapeutic intervention.

  13. AIAA Educator Academy: The Space Weather Balloon Module

    NASA Astrophysics Data System (ADS)

    Longmier, B.; Henriquez, E.; Bering, E. A.; Slagle, E.

    2013-12-01

    Educator Academy is a K-12 STEM curriculum developed by the STEM K-12 Outreach Committee of the American Institute of Aeronautics and Astronautics (AIAA). Consisting of three independent curriculum modules, K-12 students participate in inquiry-based science and engineering challenges to improve critical thinking skills and enhance problem solving skills. The Space Weather Balloon Curriculum Module is designed for students in grades 9-12. Throughout this module, students learn and refine physics concepts as well as experimental research skills. Students participate in project-based learning that is experimental in nature. Students are engaged with the world around them as they collaborate to launch a high altitude balloon equipped with HD cameras.The program leaders launch high altitude weather balloons in collaboration with schools and students to teach physics concepts, experimental research skills, and to make space exploration accessible to students. A weather balloon lifts a specially designed payload package that is composed of HD cameras, GPS tracking devices, and other science equipment. The payload is constructed and attached to the balloon by the students with low-cost materials. The balloon and payload are launched with FAA clearance from a site chosen based on wind patterns and predicted landing locations. The balloon ascends over 2 hours to a maximum altitude of 100,000 feet where it bursts and allows the payload to slowly descend using a built-in parachute. The payload is located using the GPS device. In April 2012, the Space Weather Balloon team conducted a prototype field campaign near Fairbanks Alaska, sending several student-built experiments to an altitude of 30km, underneath several strong auroral displays. To better assist teachers in implementing one or more of these Curriculum Modules, teacher workshops are held to give teachers a hands-on look at how this curriculum is used in the classroom. And, to provide further support, teachers are each

  14. Purposeful creation of a pneumothorax and chest tube placement to facilitate CT-guided coil localization of lung nodules before video-assisted thoracoscopic surgical wedge resection.

    PubMed

    Iqbal, Shams I; Molgaard, Christopher; Williamson, Christina; Flacke, Sebastian

    2014-07-01

    To evaluate the feasibility and efficacy of pneumothorax creation and chest tube insertion before computed tomography (CT)-guided coil localization of small peripheral lung nodules for video-assisted thoracoscopic surgical (VATS) wedge resection. From May 2011 to October 2013, 21 consecutive patients (seven men; mean age, 62 y; range, 42-76 y) scheduled for VATS wedge resection required CT-guided coil localization for small, likely nonpalpable peripheral lung lesions at a single institution. Outcomes were evaluated retrospectively for technical success and complications. There were 12 nodules and nine ground-glass opacities. Mean lesion distance from the pleural surface was 15 mm (range, 5-35 mm), and average size was 13 mm (range, 7-30 mm). A pneumothorax was successfully created in all patients with a Veress needle, and a chest tube was inserted. All target lesions were marked successfully, leaving one end of the coil within/beyond the lesion and the other end of the coil in the pleural space. The inserted chest tube was used to insufflate air to widen the pleural space during coil positioning and to aspirate any residual air before transfer of the patient to the operating room holding area. Intraparenchymal hemorrhages smaller than 7 cm in diameter developed in two patients during coil placement. All lesions were successfully resected with VATS. Histologic examinaiton revealed 13 primary adenocarcinomas, four metastases, and four benign lesions. Pneumothorax creation and chest tube placement before CT-guided coil localization of peripheral lung nodules for VATS wedge resection facilitates the deployment of the peripheral end of the coil in the pleural space and provides effective management of procedure-related pneumothorax until surgery. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  15. Energy from solar balloons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grena, Roberto

    2010-04-15

    Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)

  16. Buried polar residues in coiled-coil interfaces.

    PubMed

    Akey, D L; Malashkevich, V N; Kim, P S

    2001-05-29

    Coiled coils, estimated to constitute 3-5% of the encoded residues in most genomes, are characterized by a heptad repeat, (abcdefg)(n), where the buried a and d positions form the interface between multiple alpha-helices. Although generally hydrophobic, a substantial fraction ( approximately 20%) of these a- and d-position residues are polar or charged. We constructed variants of the well-characterized coiled coil GCN4-p1 with a single polar residue (Asn, Gln, Ser, or Thr) at either an a or a d position. The stability and oligomeric specificity of each variant were measured, and crystal structures of coiled-coil trimers with threonine or serine at either an a or a d position were determined. The structures show how single polar residues in the interface affect not only local packing, but also overall coiled-coil geometry as seen by changes in the Crick supercoil parameters and core cavity volumes.

  17. Comparison of endorectal coil and nonendorectal coil T2W and diffusion-weighted MRI at 3 Tesla for localizing prostate cancer: correlation with whole-mount histopathology.

    PubMed

    Turkbey, Baris; Merino, Maria J; Gallardo, Elma Carvajal; Shah, Vijay; Aras, Omer; Bernardo, Marcelino; Mena, Esther; Daar, Dagane; Rastinehad, Ardeshir R; Linehan, W Marston; Wood, Bradford J; Pinto, Peter A; Choyke, Peter L

    2014-06-01

    To compare utility of T2-weighted (T2W) MRI and diffusion-weighted MRI (DWI-MRI) obtained with and without an endorectal coil at 3 Tesla (T) for localizing prostate cancer. This Institutional Review Board-approved study included 20 patients (median prostate-specific antigen, 8.4 ng/mL). Patients underwent consecutive prostate MRIs at 3T, first with a surface coil alone, then with combination of surface, endorectal coils (dual coil) followed by robotic assisted radical prostatectomy. Lesions were mapped at time of acquisition on dual-coil T2W, DWI-MRI. To avoid bias, 6 months later nonendorectal coil T2W, DWI-MRI were mapped. Both MRI evaluations were performed by two readers blinded to pathology with differences resolved by consensus. A lesion-based correlation with whole-mount histopathology was performed. At histopathology 51 cancer foci were present ranging in size from 2 to 60 mm. The sensitivity of the endorectal dual-coil, nonendorectal coil MRIs were 0.76, 0.45, respectively. PPVs for endorectal dual-coil, nonendorectal coil MRI were 0.80, 0.64, respectively. Mean size of detected lesions with nonendorectal coil MRI were larger than those detected by dual-coil MRI (22 mm versus 17.4 mm). Dual-coil prostate MRI detected more cancer foci than nonendorectal coil MRI. While nonendorectal coil MRI is an attractive alternative, physicians performing prostate MRI should be aware of its limitations. Copyright © 2013 Wiley Periodicals, Inc.

  18. GBNV encoded movement protein (NSm) remodels ER network via C-terminal coiled coil domain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Pratibha; Savithri, H.S., E-mail: bchss@biochem.iisc.ernet.in

    interacts with NP via its N-terminal unfolded region and the NSm–NP complex could in turn interact with the ER membrane via the C-terminal coiled coil domain of NSm to form vesicles that are targeted to PD and there by assist the cell to cell movement of the viral genome complex. - Highlights: • GBNV NSm localizes to plasmodesmata via the C-terminal coiled coil domain. • GBNV NSm interacts with endoplasmic reticulum network and remodels it to vesicles. • The C-terminal coiled domain alone is responsible for vesicle formation. • The N-terminal unfolded region of NSm is involved in the re-localization of NP to PD.« less

  19. Transcatheter Embolization of Type I Endoleaks Associated With Endovascular Abdominal Aortic Aneurysm Repair Using Ethylene Vinyl Alcohol Copolymer.

    PubMed

    Graif, Assaf; Vance, Ansar Z; Garcia, Mark J; Lie, Kevin T; McGarry, Michael K; Leung, Daniel A

    2017-01-01

    To evaluate the feasibility, safety, and outcome of transcatheter embolization using ethylene vinyl alcohol copolymer (EVOH) of type I endoleaks associated with endovascular abdominal aortic aneurysm repair. Retrospective chart review was performed to identify 8 consecutive patients who had undergone EVOH embolization for type I endoleaks between 2012 and 2015. The primary approach used to access the endoleak was the perigraft technique, where the endoleak itself is catheterized at the anastomotic site. Six type Ia and 2 type Ib endoleaks were treated. In 2 patients, a direct transabdominal approach was used to access the endoleak because it was inaccessible via the perigraft approach. Coils were used in addition to EVOH in 5 cases. Residual endoleak was noted in 1 case, whereas 2 patients developed a recurrent type I endoleak during follow-up. No EVOH complications were observed. The 5 remaining patients demonstrated freedom from endoleak and reintervention at a mean follow-up of 6.9 months. Type I endoleaks can be safely and effectively treated by embolotherapy with EVOH. Larger endoleaks resulting from grossly undersized endografts appear to be unsuitable for EVOH embolization.

  20. Radical resection of a Shamblin type III carotid body tumour without cerebro-neurological deficit: Improved technique with preoperative embolization and carotid stenting.

    PubMed

    Ong, H S; Fan, X D; Ji, T

    2014-12-01

    The surgical resection of a large unfavourable Shamblin type III carotid body tumour (CBT) can be very challenging technically, with many potential significant complications. Preoperative embolization aids in shrinking the lesion, reducing intraoperative blood loss, and improving visualization of the surgical field. Preoperative internal carotid artery (ICA) stenting aids in reinforcing the arterial wall, thereby providing a better dissection plane. A woman presented to our institution with a large right-sided CBT. Failure of the preoperative temporary balloon occlusion (TBO) test emphasized the importance of intraoperative preservation of the ipsilateral ICA. A combination of both preoperative embolization and carotid stenting allowed a less hazardous radical resection of the CBT. An almost bloodless surgical field permitted meticulous dissection, hence reducing the risk of intraoperative vascular and nerve injury. Embolization and carotid stenting prior to surgical resection should be considered in cases with bilateral CBT or a skull base orientated high CBT, and for those with intracranial extension and patients who have failed the TBO test. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Single balloon versus double balloon bipedicular kyphoplasty: a systematic review and meta-analysis.

    PubMed

    Jing, Zehao; Dong, Jianli; Li, Zhengwei; Nan, Feng

    2018-06-19

    Kyphoplasty has been widely used to treat vertebral compression fractures (VCFs). In standard procedure of kyphoplasty, two balloons were inserted into the vertebral body through bipedicular and inflated simultaneously, while using a single balloon two times is also a common method in clinic to lessen the financial burden of patients. However, the effect and safety of single balloon versus double balloon bipedicular kyphoplasty are still controversy. In this systematic review and meta-analysis, eligible studies were identified through a comprehensive literature search of PubMed, Cochrane library EMBASE, Web of Science, Wanfang, CNKI, VIP and CBM until January 1, 2018. Results from individual studies were pooled using a random or fixed effects model. Seven articles were included in the systematic review and five studies were consisted in meta-analysis. We observed no significant difference between single balloon and double balloon bipedicular kyphoplasty in visual analog scale (VAS), angle (kyphotic angle and Cobb angle), consumption (operation time, cement volume and volume of bleeding), vertebral height (anterior height, medium height and posterior height) and complications (cement leakage and new VCFs), while the cost of single balloon bipedicular kyphoplasty is lower than that of double balloon bipedicular kyphoplasty. The results of our meta-analysis also demonstrated that single balloon can significantly improve the VAS, angle and vertebral height of patients suffering from VCFs. This systematic review and meta-analysis collectively concludes that single balloon bipedicular kyphoplasty is as effective as double balloon bipedicular kyphoplasty in improving clinical symptoms, deformity and complications of VCFs but not so expensive. These slides can be retrieved under Electronic Supplementary Material.

  2. Transcatheter treatment of life-threatening lower gastrointestinal bleeding due to advanced pelvic malignancy.

    PubMed

    Spinosa, D J; Angle, J F; McGraw, J K; Maurer, E J; Hagspiel, K D; Matsumoto, A H

    1998-01-01

    We present two patients with life-threatening, massive, lower gastrointestinal (GI) bleeding and locally advanced cervical carcinoma. Selective pelvic arteriography demonstrated that the site of bleeding originated from a pseudoaneurysm of the right internal iliac artery with fistulous communication to the sigmoid colon in one patient and from the left internal iliac artery into the rectum in the second patient. Transcatheter embolotherapy was then performed using balloon occlusion in one patient and coil embolization in the second patient. The iliac arteries should also be evaluated in patients with pelvic cancer who present with lower GI bleeding.

  3. Dynamic allostery of protein alpha helical coiled-coils

    PubMed Central

    Hawkins, Rhoda J; McLeish, Tom C.B

    2005-01-01

    Alpha helical coiled-coils appear in many important allosteric proteins such as the dynein molecular motor and bacteria chemotaxis transmembrane receptors. As a mechanism for transmitting the information of ligand binding to a distant site across an allosteric protein, an alternative to conformational change in the mean static structure is an induced change in the pattern of the internal dynamics of the protein. We explore how ligand binding may change the intramolecular vibrational free energy of a coiled-coil, using parameterized coarse-grained models, treating the case of dynein in detail. The models predict that coupling of slide, bend and twist modes of the coiled-coil transmits an allosteric free energy of ∼2kBT, consistent with experimental results. A further prediction is a quantitative increase in the effective stiffness of the coiled-coil without any change in inherent flexibility of the individual helices. The model provides a possible and experimentally testable mechanism for transmission of information through the alpha helical coiled-coil of dynein. PMID:16849225

  4. Predicting helix orientation for coiled-coil dimers

    PubMed Central

    Apgar, James R.; Gutwin, Karl N.; Keating, Amy E.

    2008-01-01

    The alpha-helical coiled coil is a structurally simple protein oligomerization or interaction motif consisting of two or more alpha helices twisted into a supercoiled bundle. Coiled coils can differ in their stoichiometry, helix orientation and axial alignment. Because of the near degeneracy of many of these variants, coiled coils pose a challenge to fold recognition methods for structure prediction. Whereas distinctions between some protein folds can be discriminated on the basis of hydrophobic/polar patterning or secondary structure propensities, the sequence differences that encode important details of coiled-coil structure can be subtle. This is emblematic of a larger problem in the field of protein structure and interaction prediction: that of establishing specificity between closely similar structures. We tested the behavior of different computational models on the problem of recognizing the correct orientation - parallel vs. antiparallel - of pairs of alpha helices that can form a dimeric coiled coil. For each of 131 examples of known structure, we constructed a large number of both parallel and antiparallel structural models and used these to asses the ability of five energy functions to recognize the correct fold. We also developed and tested three sequenced-based approaches that make use of varying degrees of implicit structural information. The best structural methods performed similarly to the best sequence methods, correctly categorizing ∼81% of dimers. Steric compatibility with the fold was important for some coiled coils we investigated. For many examples, the correct orientation was determined by smaller energy differences between parallel and antiparallel structures distributed over many residues and energy components. Prediction methods that used structure but incorporated varying approximations and assumptions showed quite different behaviors when used to investigate energetic contributions to orientation preference. Sequence based methods were

  5. Single- and double-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with Roux-en-Y plus hepaticojejunostomy anastomosis and Whipple resection.

    PubMed

    Itokawa, Fumihide; Itoi, Takao; Ishii, Kentaro; Sofuni, Atsushi; Moriyasu, Fuminori

    2014-04-01

    In patients with Roux-en-Y hepaticojejunostomy (HJ with R-Y) and Whipple resection, endoscopic retrograde cholangiopancreatography (ERCP) can be challenging. We report our experience with ERCP using balloon-assisted enteroscopy (BAE) (BAE-ERCP) in patients with HJ with R-Y, and Whipple resection. BAE-ERCP procedures were carried out in 62 patients (HJ with R-Y:Whipple resection=34:28). Overall, the rates of reaching the anastomosis were 85.3% (29/34) in HJ with R-Y and 96.4% (27/28) in Whipple resection. In terms of HJ with R-Y, insertion success rate by standard single-balloon enteroscopy (SBE) was 89.3% (25/28). Insertion success rate by short BAE, including SBE and double-balloon enteroscopy (DBE), was 50% (3/6). There was a statistically significant difference of insertion success rate between standard long BE and short BE (P=0.021). However, in the Whipple patients, insertion success rate by standard and short SBE was 93.8% (15/16) and 91.7% (11/12), respectively. Initial insertion success rate by short BAE in Whipple patients was significantly higher than in HJ with R-Y (91.7% vs 50%, P=0.045). Therapeutic interventions included dilation of anastomosis stricture, stone extraction, endoscopic mechanical lithotripsy, biliary stent placement, stent extraction, endoscopic nasobiliary drainage, direct cholangioscopy, and electrohydraulic lithotripsy. Our HJ with R-Y series and Whipple series treatment success rate was 90% (18/20) and 95.0% (19/20), respectively. BAE-ERCP enabled ERCP to be carried out in patients with HJ. It is considered safe and feasible. Further experience and device improvement are needed. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  6. Prediction of Symptomatic Embolism in Filipinos With Infective Endocarditis Using the Embolic Risk French Calculator

    PubMed Central

    Aherrera, Jaime Alfonso M.; Abola, Maria Teresa B.; Balabagno, Maria Margarita O.; Abrahan, Lauro L.; Magno, Jose Donato A.; Reganit, Paul Ferdinand M.; Punzalan, Felix Eduardo R.

    2016-01-01

    Background Cardioembolic events are life-threatening complications of infective endocarditis (IE). The embolic risk French calculator estimates the embolic risk in IE computed on admission. Variables in this tool include age, diabetes, atrial fibrillation, prior embolism, vegetation length, and Staphylococcus aureus on culture. A computed risk of > 7% was considered high in the development of this tool. Knowledge of this risk applied in our local setting is important to guide clinicians in preventing such catastrophic complications. Among patients with IE, we aim to determine the efficacy of the embolic risk French calculator, using a computed score of > 7%, in predicting major embolic events. Methods All adults admitted from 2013 to 2016 with definite IE were included. The risk for embolic events was computed on admission. All were monitored for the duration of admission for the occurrence of the primary outcome (any major embolic event: arterial emboli, intracranial hemorrhage, pulmonary infarcts, or aneurysms). Secondary outcomes were: 1) composite of death and embolic events; and 2) death from any cause. Results Eighty-seven adults with definite IE were included. Majority had a valvular heart disease and preserved ejection fraction (EF). The mitral valve was most commonly involved. Embolic events occurred in 25 (29%). Multivariate analysis identified a high embolic score > 7% (relative risk (RR): 15.12, P < 0.001), vegetation area ≥ 18 mm2 (RR: 6.39, P < 0.01), and a prior embolism (RR: 5.18, P = 0.018) to be independent predictors of embolic events. For the composite of embolic events and death, independent predictors include a high score of > 7% (RR: 13.56, P < 0.001) and a prior embolus (RR: 13.75, P = 0.002). Independent predictors of death were a high score > 7% (RR: 6.20, P = 0.003) and EF ≤ 45% (RR: 9.91, P = 0.004). Conclusion Cardioembolic events are more prevalent in our study compared to previous data. The embolic risk French calculator is a

  7. Balloon Design Software

    NASA Technical Reports Server (NTRS)

    Farley, Rodger

    2007-01-01

    PlanetaryBalloon Version 5.0 is a software package for the design of meridionally lobed planetary balloons. It operates in a Windows environment, and programming was done in Visual Basic 6. By including the effects of circular lobes with load tapes, skin mass, hoop and meridional stress, and elasticity in the structural elements, a more accurate balloon shape of practical construction can be determined as well as the room-temperature cut pattern for the gore shapes. The computer algorithm is formulated for sizing meridionally lobed balloons for any generalized atmosphere or planet. This also covers zero-pressure, over-pressure, and super-pressure balloons. Low circumferential loads with meridionally reinforced load tapes will produce shapes close to what are known as the "natural shape." The software allows for the design of constant angle, constant radius, or constant hoop stress balloons. It uses the desired payload capacity for given atmospheric conditions and determines the required volume, allowing users to design exactly to their requirements. The formulations are generalized to use any lift gas (or mixture of gases), any atmosphere, or any planet as described by the local acceleration of gravity. PlanetaryBalloon software has a comprehensive user manual that covers features ranging from, but not limited to, buoyancy and super-pressure, convenient design equations, shape formulation, and orthotropic stress/strain.

  8. Fat embolism syndrome.

    PubMed

    Dhar, Dinesh

    2012-12-01

    Nearly all patients following fractures of bones develop sub-clinical form of fat embolism but the classical form of fat embolism syndrome (FES) presents with triad of respiratory, neurologic and dermal manifestations. Non-traumatic conditions can also have fat embolism, but the incidence is very low. The diagnosis is mainly clinical supported by laboratory and radiological finding. Treatment is mainly supportive with early stabilization of fractured bones. In most cases, prognosis is good if the condition is detected and treated early. High index of suspicion in polytrauma patient is the key to early diagnosis of this condition. This report describes two cases of FES, the second case being fulminant fat embolism with added mortality.

  9. Embolization of arterial gastric supply in obesity (EMBARGO): an endovascular approach in the management of morbid obesity. proof of the concept in the porcine model.

    PubMed

    Diana, Michele; Pop, Raoul; Beaujeux, Rémy; Dallemagne, Bernard; Halvax, Peter; Schlagowski, Isabel; Liu, Yu-Yin; Diemunsch, Pierre; Geny, Bernard; Lindner, Veronique; Marescaux, Jacques

    2015-03-01

    Embolization of the left gastric artery (LGA) reduces circulating levels of ghrelin, but might prevent from further obesity surgery, particularly sleeve gastrectomy (SG), since the gastroesophageal junction (GEJ), depending on LGA, would be devascularized. Our aim was to evaluate, in an experimental animal study, an endovascular approach targeting arteries of the gastroepiploic arcade aiming to modulate ghrelin levels and to generate an increased vascular supply of the GEJ to reduce the risks of staple-line leaks after SG. Seven pigs underwent embolization of both left and right gastroepiploic arteries (LGEA and RGEA) using 500-700-μ microspheres (embolization of arterial gastric supply in obesity (EMBARGO)-alpha). A SG was performed in six pigs 3 weeks after EMBARGO-alpha and on eight controls. Capillary lactates were measured at the cardia and pylorus. Five pigs underwent coiling of RGEA and embolization of LGEA using both coils and 100-300-μ microspheres (EMBARGO-beta). Ghrelin levels were assessed before and once per week after both EMBARGOs. Control celiac trunk angiography was performed at 3 weeks (alpha) and 4 weeks (beta). No significant ghrelin reduction was obtained with EMBARGO-alpha at 3 weeks when compared to baseline. Significant ghrelin reduction was found 3 weeks (p = 0.0363) and 4 weeks (p = 0.025) after EMBARGO-beta. Post-EMBARGO-alpha animals presented a significantly lower increase in cardia lactates when compared to controls after SG. Control angiography showed a significantly increased fundic vascular network in 5/6 animals after EMBARGO-alpha and in 5/5 after EMBARGO-beta. EMBARGO is effective to decrease ghrelin production and can enhance the vascular supply of the GEJ, preparing the vascular background for a SG.

  10. Intraoperative aortic balloon occlusion in patients with placenta previa and/or placenta accreta: a retrospective study.

    PubMed

    Luo, Fangyuan; Xie, Lan; Xie, Ping; Liu, Siwei; Zhu, Yue

    2017-04-01

    To introduce the primary experience of using aortic balloon catheters during cesarean section for placenta previa and/or placenta accreta. From January 2013 to May 2015, 43 patients who were preoperatively diagnosed with major placenta previa and/or placenta accreta and who underwent prophylactic aortic catheterization before caesarean section (CS) were included in the study. We analyzed the clinical data of the study population. Surgery- and catheterization-related complications were also reported. Major placenta previa or placenta accreta was surgically confirmed in 42 patients, 28 of whom had both conditions. The mean patient age was 32.3 ± 5.5 years, whereas the median gestational age at delivery was 260 (range, 153-280) days. Twenty-nine (67.4%) patients had previously undergone CS, and 13 (30%) patients had undergone emergency surgery for antenatal hemorrhage. The median estimated blood loss during surgery was 500 (range, 100-3,000) mL, and the median duration of occlusion was 20 (range, 5-32) minutes. Hysterectomy was performed in five (11.6%) patients and uterine artery embolization in two (4.6%) patients. Two patients with placenta percreta experienced surgery-related complications, and two patients required hospital readmission. No major catheterization-related complications were observed. Forty-two live births were recorded, and the Apgar score of the infants at 5 minutes was > 7. Intraoperative aortic balloon occlusion is a relatively safe method for treating placenta previa and/or placenta accreta during scheduled and emergency CS and might be helpful to prevent hysterectomy and embolization in women wishing to preserve fertility. Copyright © 2017. Published by Elsevier B.V.

  11. Successful embolization of iatrogenic ruptured coronary artery using Onyx: a new technique.

    PubMed

    Asouhidou, I; Katsaridis, V

    2014-12-01

    Iatrogenic perforation of coronary artery is rare during percutaneous coronary intervention (PCI); however the complications are life-threatening. Patients in this clinical setting may be treated either by stent placement, closure of the perforation with fibrin glue or coils, or with emergency bypass surgery. Onyx, a new material that has been used successfully in cerebral arteries, represents a new and safe alternative. The advantage of Onyx is that it is easily injected through a microcatheter and it allows for a longer injection time having also the ability to reach difficult anatomical locations. We present the first case of successful embolization of a right coronary artery perforation during coronary angiography using Onyx.

  12. Computational analysis of aortic hemodynamics during total and partial extracorporeal membrane oxygenation and intra-aortic balloon pump support.

    PubMed

    Caruso, Maria Vittoria; Gramigna, Vera; Renzulli, Attilio; Fragomeni, Gionata

    2016-01-01

    The extracorporeal membrane oxygenation (ECMO) is a temporary, but prolonged circulatory support for cardiopulmonary failure. Clinical evidence suggests that pulsed flow is healthier than non pulsatile perfusion. The aim of this study was to computationally evaluate the effects of total and partial ECMO assistance and pulsed flow on hemodynamics in a patient-specific aorta model. The pulsatility was obtained by means of the intra-aortic balloon pump (IABP), and two different cases were investigated, considering a cardiac output (CO) of 5 L/min: Case A - total assistance - the whole flow delivered through the ECMO arterial cannula; Case B - partial assistance - flow delivered half through the cannula and half through the aorta. Computational fluid dynamic (CFD) analysis was carried out using the multiscale approach to couple the 3D aorta model with the lumped parameter model (resistance boundary condition). In case A pulsatility followed the balloon radius change, while in case B it was mostly influenced by the cardiac one. Furthermore, during total assistance, a blood stagnation occurred in the ascending aorta; in the case of partial assistance, the flow was orderly when the IABP was on and was chaotic when the balloon was off. Moreover, the mean arterial pressure (MAP) was higher in case B. The wall shear stress was worse in ascending aorta in case A. Partial support is hemodynamically advisable.

  13. Proposed diagnostic criteria for the case definition of amniotic fluid embolism in research studies

    PubMed Central

    Clark, Steven L.; Romero, Roberto; Dildy, Gary A.; Callaghan, William M.; Smiley, Richard M.; Bracey, Arthur W.; Hankins, Gary D.; D’Alton, Mary E.; Foley, Mike; Pacheco, Luis D.; Vadhera, Rakesh B.; Herlihy, J. Patrick; Berkowitz, Richard L.; Belfort, Michael A.

    2016-01-01

    Amniotic fluid embolism is a leading cause of maternal mortality in developed countries. Our understanding of risk factors, diagnosis, treatment, and prognosis is hampered by a lack of uniform clinical case definition; neither histologic nor laboratory findings have been identified unique to this condition. Amniotic fluid embolism is often overdiagnosed in critically ill peripartum women, particularly when an element of coagulopathy is involved. Previously proposed case definitions for amniotic fluid embolism are nonspecific, and when viewed through the eyes of individuals with experience in critical care obstetrics, would include women with a number of medical conditions much more common than amniotic fluid embolism. We convened a working group under the auspices of a committee of the Society for Maternal-Fetal Medicine and the Amniotic Fluid Embolism Foundation whose task was to develop uniform diagnostic criteria for the research reporting of amniotic fluid embolism. These criteria rely on the presence of the classic triad of hemodynamic and respiratory compromise accompanied by strictly defined disseminated intravascular coagulopathy. It is anticipated that limiting research reports involving amniotic fluid embolism to women who meet these criteria will enhance the validity of published data and assist in the identification of risk factors, effective treatments, and possibly useful biomarkers for this condition. A registry has been established in conjunction with the Perinatal Research Branch of the Eunice Kennedy Shriver National Institute of Child Health and Human Development to collect both clinical information and laboratory specimens of women with suspected amniotic fluid embolism in the hopes of identifying unique biomarkers of this condition. PMID:27372270

  14. Endovascular embolization of carotid-cavernous fistulas: A pioneering experience in Peru

    PubMed Central

    Plasencia, Andres R.; Santillan, Alejandro

    2012-01-01

    Background: Endovascular embolization represents the method of choice for the treatment of carotid-cavernous fistulas (CCFs). Methods: We report our experience using the endovascular technique in 24 patients harboring 25 CCFs treated between October 1994 and April 2010, with an emphasis on the role of detachable balloons for the treatment of direct CCFs. Results: Of the 16 patients who presented with direct CCFs (Barrow Type A CCFs) (age range, 7–62 years; mean age, 34.3 years), 14 were caused by traumatic injury and 2 by a ruptured internal carotid artery (ICA) aneurysm. Eight patients (age range, 32–71 years; mean age, 46.5 years) presented with nine indirect CCFs (Barrow Types B, C, and D). The clinical follow-up after endovascular treatment ranged from 2 to 108 months (mean, 35.2 months). In two cases (8%), the endovascular approach failed. Symptomatic complications related to the procedure occurred in three patients (12.5%): transient cranial nerve palsy in two patients and a permanent neurological deficit in one patient. Detachable balloons were used in 13 out of 16 (81.3%) direct CCFs and were associated with a cure rate of 92.3%. Overall, the angiographic cure rate was obtained in 22 out of 25 (88%) fistulas. Patients presenting with III nerve palsy improved gradually between 1 day and 6 months after treatment. Good clinical outcomes [modified Rankin scale (mRS) ≤ 2] were observed in 22 out of 24 (91.6%) patients at last follow-up. Conclusions: Endovascular treatment using detachable balloons still constitutes a safe and effective method to treat direct carotid-cavernous fistulas. PMID:22363900

  15. An update on the clinical use of drug-coated balloons in percutaneous coronary interventions.

    PubMed

    Cheng, Yanping; Leon, Martin B; Granada, Juan F

    2016-06-01

    Drug-coated balloons (DCB) promise to deliver anti-proliferative drugs and prevent restenosis leaving nothing behind. Although, randomized clinical trials have demonstrated their efficacy for the treatment of in-stent restenosis, clinical evidence supporting their use in other coronary applications is still lacking. This review summarizes the development status of clinically available DCB technologies and provides an update on the current data for their coronary use. Current generation DCB prevent restenosis by delivering paclitaxel particles on the surface of the vessel wall. Although clinically available technologies share a common mechanism of action, important differences in pharmacokinetic behavior and safety profiles do exist. Future technological improvements include the development of coatings displaying: high transfer efficiency; low particle embolization potential; and alternative drug formulations. Optimized balloon-based delivery systems and drug encapsulation technologies also promise to improve the technical limitations of current generation DCB. Although proving clinical superiority against DES may prove to be difficult in mainstream applications (i.e., de novo), new generation DCB technologies have the potential to achieve a strong position in the interventional field in clinical settings in which the efficacy of DES use is not proven or justified (i.e., bifurcations).

  16. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2017-12-08

    The Halley station team members assisted the BARREL team with the launches. Here, one gives the thumbs up to start inflating a BARREL balloon. Credit: NASA/Goddard/BARREL/M. Krzysztofowicz Read more: www.nasa.gov/content/nasas-barrel-returns-successful-from... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  17. Balloon dilatation of benign and malignant esophageal strictures. Blind retrograde balloon dilatation.

    PubMed

    Graham, D Y; Smith, J L

    1985-06-01

    Balloon esophageal dilatation offers many theoretical advantages (safety, speed, and patient comfort) over dilatation with mercury-filled bougies or with the Eder-Puestow system. The authors used balloon dilators in 22 patients with dysphagia secondary to benign or malignant strictures. Dilatation was performed with fluoroscopic guidance, blindly, or by a combination of these techniques. For "blind" stricture dilatation, an Eder-Puestow spring-tipped guide wire is placed into the stomach using a fiberoptic endoscope. The distance from the incisor teeth to the stricture is measured, and the balloon shaft is marked to indicate when the middle of the balloon is within the stricture. Dilatation is then performed using the antegrade or, the preferred, retrograde technique. Finally, the dilated stricture is calibrated by pulling an inflated balloon through the previously strictured area without difficulty. An attempt was made to achieve an esophageal diameter of 15 mm at the initial dilatation episode, and patient discomfort was used as a guide as to the final diameter. The balloon dilatation technique was highly successful, and a stricture diameter of 15 mm (45-47 French) was achieved at the initial dilatation in most instances. Malignant strictures were easily dilated. Balloon dilatation is convenient, effective, quick, and potentially safer than the previous Eder-Puestow or mercury-filled bougie techniques.

  18. Selective Intra-procedural AAA sac Embolization During EVAR Reduces the Rate of Type II Endoleak.

    PubMed

    Mascoli, C; Freyrie, A; Gargiulo, M; Gallitto, E; Pini, R; Faggioli, G; Serra, C; De Molo, C; Stella, A

    2016-05-01

    The pre-treatment presence of at least six efferent patent vessels (EPV) from the AAA sac and/or AAA thrombus volume ratio (VR%) <40% are considered to be positive predictive factors for persistent type II endoleak (ELIIp). The aim of the present study was to evaluate the effectiveness of sac embolization during EVAR in patients with pre-operative morphological risk factors (p-MRF) for ELIIp. Patients undergoing EVAR and intra-procedural AAA sac embolization (Group A, 2012-2013) were retrospectively selected and compared with a control group of patients with the same p-MRF, who underwent EVAR without intra-procedural sac embolization (Group B, 2008-2010). The presence of ELIIp was evaluated by duplex ultrasound at 0 and 6 months, and by contrast enhanced ultrasound at 12 months. The association between AAA diameter, age, COPD, smoking, anticoagulant therapy, and AAA sac embolization with ELIIp was evaluated using multiple logistic regression. The primary endpoint was the effectiveness of the intra-procedural AAA sac embolization for ELIIp prevention. Secondary endpoints were AAA sac evolution and freedom from ELIIp and embolization related re-interventions at 6-12 months. Seventy patients were analyzed: 26 Group A and 44 Group B; the groups were homogeneous for clinical/morphological characteristics. In Group A the median number of coils positioned in AAA sac was 4.1 (IQR 1). There were no complications related to the embolization procedures. A significantly lower number of ELIIp was detected in Group A than in Group B (8/26 vs. 33/44, respectively, p < .001) at discharge, and this was confirmed at 6-12 months (7/26 vs. 30/44 respectively, p = .001, and 5/25 vs. 32/44, respectively, p < .001). On multivariate analysis, intra-procedural AAA sac embolization was the only factor independently associated with freedom from ELIIp at 6 (OR 0.196, 95% CI 0.06-0.63; p = .007) and 12 months (OR 0.098, 95% CI 0.02-0.35; p < .001). No differences in median AAA sac

  19. Transvenous embolization in spontaneous direct carotid-cavernous fistula in childhood

    PubMed Central

    Mercado, Glenna B.; Irie, Keiko; Negoro, Makoto; Moriya, Shigeta; Tanaka, Teppei; Ohmura, Masahiro; Sadato, Akiyo; Hayakawa, Motuharu; Sano, Hirotoshi

    2011-01-01

    Carotid cavernous fistula (CCF) is an abnormal arteriovenous communication in the cavernous sinus. Direct CCF results from a tear in the intracavernous carotid artery. Typically, it has a high flow and usually presents with oculo-orbital venous congestive features such as exophthalmos, chemosis, and sometimes oculomotor or abducens cranial nerve palsy. Indirect CCF generally occurs spontaneously with subtle signs. We report a rare case of spontaneous direct CCF in childhood who did not have the usual history of craniofacial trauma or connective tissue disorder but presented with progressive chemosis and exophthalmos of the right eye. This report aims also to describe the safety and success of transvenous embolization with coils of the superior ophthalmic vein and cavernous sinus through the inferior petrosal sinus. PMID:22059104

  20. Scientific Balloons for Venus Exploration

    NASA Astrophysics Data System (ADS)

    Cutts, James; Yavrouian, Andre; Nott, Julian; Baines, Kevin; Limaye, Sanjay; Wilson, Colin; Kerzhanovich, Viktor; Voss, Paul; Hall, Jeffery

    Almost 30 years ago, two balloons were successfully deployed into the atmosphere of Venus as an element of the VeGa - Venus Halley mission conducted by the Soviet Union. As interest in further Venus exploration grows among the established planetary exploration agencies - in Europe, Japan, Russia and the United States, use of balloons is emerging as an essential part of that investigative program. Venus balloons have been proposed in NASA’s Discovery program and ESA’s cosmic vision program and are a key element in NASA’s strategic plan for Venus exploration. At JPL, the focus for the last decade has been on the development of a 7m diameter superpressure pressure(twice that of VeGa) capable of carrying a 100 kg payload (14 times that of VeGA balloons), operating for more than 30 days (15 times the 2 day flight duration of the VeGa balloons) and transmitting up to 20 Mbit of data (300 times that of VeGa balloons). This new generation of balloons must tolerate day night transitions on Venus as well as extended exposure to the sulfuric acid environment. These constant altitude balloons operating at an altitude of about 55 km on Venus where temperatures are benign can also deploy sondes to sound the atmosphere beneath the probe and deliver deep sondes equipped to survive and operate down to the surface. The technology for these balloons is now maturing rapidly and we are now looking forward to the prospects for altitude control balloons that can cycle repeatedly through the Venus cloud region. One concept, which has been used for tropospheric profiling in Antarctica, is the pumped-helium balloon, with heritage to the anchor balloon, and would be best adapted for flight above the 55 km level. Phase change balloons, which use the atmosphere as a heat engine, can be used to investigate the lower cloud region down to 30 km. Progress in components for high temperature operation may also enable investigation of the deep atmosphere of Venus with metal-based balloons.

  1. Embolization of Brain Aneurysms and Fistulas

    MedlinePlus

    ... Resources Professions Site Index A-Z Embolization of Brain Aneurysms and Arteriovenous Malformations/Fistulas Embolization of brain ... Brain Aneurysms and Fistulas? What is Embolization of Brain Aneurysms and Fistulas? Embolization of brain aneurysms and ...

  2. Embolization of the Internal Iliac Artery: Cost-Effectiveness of Two Different Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pellerin, Olivier, E-mail: olivier.pellerin@egp.aphp.f; Caruba, Thibaud; Kandounakis, Yanis

    2008-11-15

    The purpose of this study was to compare the cost-effectiveness of coils versus the Amplatzer Vascular Plug (AVP) for occlusion of the internal iliac artery (IAA). Between 2002 and January 2006, 13 patients (mean age 73 {+-} 13 years) were referred for stent-grafting of abdominal aortic aneurysm (n = 6); type I distal endoleak (n = 3), isolated iliac aneurysm (n = 3), or rupture of a common iliac aneurysm (n = 1). In all patients, extension of the stent-graft was needed because the distal neck was absent. Two different techniques were used to occlude the IIA: AVP in sevenmore » patients (group A) and coil embolization in six patients (group C). Immediate results and direct material costs were assessed retrospectively. Immediate success was achieved in all patients, and simultaneous stent-grafting was successfully performed in two of six patients in group C versus five of seven patients in group A. In all group A patients, a single AVP was sufficient to achieve occlusion of the IIA, accounting for a mean cost of 485 Euro , whereas in group C patients, an average of 7 {+-} 3 coils were used, accounting for a mean cost of 1,745 Euro . Mean average cost savings using the AVP was 1,239 Euro . When IIA occlusion is needed, the AVP allows a single-step procedure at significant cost savings.« less

  3. Why bundled payments could drive innovation: an example from interventional oncology.

    PubMed

    Steele, Joseph R; Jones, A Kyle; Ninan, Elizabeth P; Clarke, Ryan K; Odisio, Bruno C; Avritscher, Rony; Murthy, Ravi; Mahvash, Armeen

    2015-03-01

    Some have suggested that the current fee-for-service health care payment system in the United States stifles innovation. However, there are few published examples supporting this concept. We implemented an innovative temporary balloon occlusion technique for yttrium 90 radioembolization of nonresectable liver cancer. Although our balloon occlusion technique was associated with similar patient outcomes, lower cost, and faster procedure times compared with the standard-of-care coil embolization technique, our technique failed to gain widespread acceptance. Financial analysis revealed that because the balloon occlusion technique avoided a procedural step associated with a lucrative Current Procedural Terminology billing code, this new technique resulted in a significant decrease in hospital and physician revenue in the current fee-for-service payment system, even though the new technique would provide a revenue enhancement through cost savings in a bundled payment system. Our analysis illustrates how in a fee-for-service payment system, financial disincentives can stifle innovation and advancement of health care delivery. Copyright © 2015 by American Society of Clinical Oncology.

  4. Scientific Ballooning Activities and Recent Developments in Technology and Instrumentation of the TIFR Balloon Facility, Hyderabad

    NASA Astrophysics Data System (ADS)

    Buduru, Suneel Kumar

    2016-07-01

    The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) is a unique center of expertise working throughout the year to design, fabricate and launch scientific balloons mainly for space astronomy, atmospheric science and engineering experiments. Recently TIFR-BF extended its support to new user scientists for conducting balloon launches for biological and middle atmospheric sciences. For the first time two balloon launches conducted for sending live lab rats to upper stratosphere and provided launch support for different balloon campaigns such as Tropical Tropopause Dynamics (TTD) to study water vapour content in upper tropospheric and lower stratospheric regions over Hyderabad and the other balloon campaign to study the Asian Tropopause Aerosol Layer (BATAL) during the Indian summer monsoon season. BATAL is the first campaign to conduct balloon launches during active (South-West) monsoon season using zero pressure balloons of different volumes. TIFR-BF also provided zero pressure and sounding balloon support to various research institutes and organizations in India and for several international space projects. In this paper, we present details on our increased capability of balloon fabrication for carrying heavier payloads, development of high strength balloon load tapes and recent developments of flight control and safety systems. A summary of the various flights conducted in two years will be presented along with the future ballooning plans.

  5. Telescope Systems for Balloon-Borne Research

    NASA Technical Reports Server (NTRS)

    Swift, C. (Editor); Witteborn, F. C. (Editor); Shipley, A. (Editor)

    1974-01-01

    The proceedings of a conference on the use of balloons for scientific research are presented. The subjects discussed include the following: (1) astronomical observations with balloon-borne telescopes, (2) orientable, stabilized balloon-borne gondola for around-the-world flights, (3) ultraviolet stellar spectrophotometry from a balloon platform, (4) infrared telescope for balloon-borne infrared astronomy, and (5) stabilization, pointing, and command control of balloon-borne telescopes.

  6. Endovascular Treatment of Recurrent Coiled Aneurysms: Assessment of Complications and Rebleeding during a Decade in a Single Center

    PubMed Central

    Sedat, J.; Chau, Y.; Moubarak, K.; Vargas, J.; Lonjon, M.

    2012-01-01

    Summary Recurrence is the main drawback of aneurysmal coiling. Additional coiling must sometimes be considered in patients with reopened aneurysms and expose the patient to the risk of a new procedure. Our purpose was to assess the procedural complications of additional endovascular treatments in patients with previously coiled but recurrent aneurysms treated by two neurointerventionalists during a decade in a single center. Between 1999 and 2009, 637 intracranial aneurysms were coiled and had a clinical and angiographic follow-up at our institution. Following the first embolization, 44 aneurysms were retreated with coils and 11 were retreated a second time. Retreatment was decided when a recurrence showed at angiographic follow-up. Early retreatments, performed in the first month after an incomplete or failed initial coiling, were excluded. We retrospectively analysed the procedural complications, rebleeding, clinical and angiographic outcomes of the retreatments. No death or bleeding occurred in these 55 additional procedures. We had three periprocedural thromboembolic complications and the procedural permanent morbidity was 1.8%. Clinical and angiographic follow-ups ranged from six months to nine years (mean: 37 months, median: 36 months). Thirty-seven of the 44 retreated aneurysms (84%) showed a stable occlusion at follow-up. Seven showed a recurrence but were not retreated due to the stability of the packing. No rebleeding was observed during the follow-up period. Our results show that endovascular treatment of recurrent aneurysms is associated with a low procedural risk. PMID:22440596

  7. Endovascular treatment of recurrent coiled aneurysms: assessment of complications and rebleeding during a decade in a single center.

    PubMed

    Sedat, J; Chau, Y; Moubarak, K; Vargas, J; Lonjon, M

    2012-03-01

    Recurrence is the main drawback of aneurysmal coiling. Additional coiling must sometimes be considered in patients with reopened aneurysms and expose the patient to the risk of a new procedure. Our purpose was to assess the procedural complications of additional endovascular treatments in patients with previously coiled but recurrent aneurysms treated by two neurointerventionalists during a decade in a single center. Between 1999 and 2009, 637 intracranial aneurysms were coiled and had a clinical and angiographic follow-up at our institution. Following the first embolization, 44 aneurysms were retreated with coils and 11 were retreated a second time. Retreatment was decided when a recurrence showed at angiographic follow-up. Early retreatments, performed in the first month after an incomplete or failed initial coiling, were excluded. We retrospectively analysed the procedural complications, rebleeding, clinical and angiographic outcomes of the retreatments. No death or bleeding occurred in these 55 additional procedures. We had three periprocedural thromboembolic complications and the procedural permanent morbidity was 1.8%. Clinical and angiographic follow-ups ranged from six months to nine years (mean: 37 months, median: 36 months). Thirty-seven of the 44 retreated aneurysms (84%) showed a stable occlusion at follow-up. Seven showed a recurrence but were not retreated due to the stability of the packing. No rebleeding was observed during the follow-up period. Our results show that endovascular treatment of recurrent aneurysms is associated with a low procedural risk.

  8. Status of the NASA Balloon Program

    NASA Astrophysics Data System (ADS)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-02-01

    In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.

  9. The National Scientific Balloon Facility. [balloon launching capabilities of ground facility

    NASA Technical Reports Server (NTRS)

    Kubara, R. S.

    1974-01-01

    The establishment and operation of the National Scientific Balloon Facility are discussed. The balloon launching capabilities are described. The ground support systems, communication facilities, and meteorological services are analyzed.

  10. Transarterial Onyx Embolization for Patients with Cavernous Sinus Dural Arteriovenous Fistulas Who Have Failed Transvenous Embolization.

    PubMed

    Wen, Jun; Duan, Chuan-Zhi; Huang, Li-Jing; Zhang, Xin; He, Xu-Ying; Li, Xi-Feng

    2015-09-01

    Transvenous embolization is the treatment of choice for cavernous sinus dural arteriovenous fistulas (csDAVFs) despite occasional difficulty in transvenous catheterization. We reported our experience in the treatment of csDAVFs by transarterial Onyx embolization in patients who had failed transvenous catheterization. We reviewed the clinical and radiographic records of csDAVFs patients receiving transarterial Onyx embolization after failed transvenous Onyx embolization at our institution over a period of 31 months. Success was defined as complete or near complete occlusion upon angiographic examination. In seven cases, the microcatheter failed to reach the cavernous sinus; in the remaining case, the internal jugular vein was occlusive. Eight sessions of the embolization and catheterization procedures via the arterial routes were conducted. Among them, five cases via the middle meningeal artery and the other three via the accessory meningeal artery. Angiography, immediately after embolization, revealed complete occlusion in seven cases (87.5 %) and partial occlusion in the remaining case. Angiographic follow-up (range, 6-10 months) showed that all patients achieved complete embolization. In cases where transvenous embolization of the cavernous sinus is difficult, transarterial embolization of the fistulas offers a safe and effective alternative.

  11. Investigation of hot air balloon fatalities.

    PubMed

    McConnell, T S; Smialek, J E; Capron, R G

    1985-04-01

    The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.

  12. Retrofitting coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merrill, D.G.

    1995-12-01

    This article provides guidelines for maintaining efficiency by determining which coils require replacement and the selection of replacement coils to match the originals in terms of size, performance, materials, and material thickness. Coils in the Rio Hondo College have been in use 24 years. The author recently found an installation where the coils installed 20 years ago look like new, which is the result of a highly effective preventive maintenance program. But these exceptions are countered by some installations lasting considerably less time. Periodic coil inspections are the best way to find leaks and deterioration. Leaking coils have an unhappymore » way of announcing their presence through unwanted water on ceilings, walls, and machine room floors. Minuscule streams of water impinge on nonwater-tight housings or are picked up in the air stream to leak out of the ductwork. Coil return bends and headers seem to have the greater incidence of failure and should be checked first for pinhole or joint leaks. Also, check along the points where the tubes penetrate the tube sheets. The coil headers should be checked as should the tubes along the front and backside of the coil. The more rows the coil has, the more difficult this latter assignment becomes.« less

  13. A comparative study of internally and externally capped balloons using small scale test balloons

    NASA Technical Reports Server (NTRS)

    Bell, Douglas P.

    1994-01-01

    Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.

  14. Proposed diagnostic criteria for the case definition of amniotic fluid embolism in research studies.

    PubMed

    Clark, Steven L; Romero, Roberto; Dildy, Gary A; Callaghan, William M; Smiley, Richard M; Bracey, Arthur W; Hankins, Gary D; D'Alton, Mary E; Foley, Mike; Pacheco, Luis D; Vadhera, Rakesh B; Herlihy, J Patrick; Berkowitz, Richard L; Belfort, Michael A

    2016-10-01

    Amniotic fluid embolism is a leading cause of maternal mortality in developed countries. Our understanding of risk factors, diagnosis, treatment, and prognosis is hampered by a lack of uniform clinical case definition; neither histologic nor laboratory findings have been identified unique to this condition. Amniotic fluid embolism is often overdiagnosed in critically ill peripartum women, particularly when an element of coagulopathy is involved. Previously proposed case definitions for amniotic fluid embolism are nonspecific, and when viewed through the eyes of individuals with experience in critical care obstetrics, would include women with a number of medical conditions much more common than amniotic fluid embolism. We convened a working group under the auspices of a committee of the Society for Maternal-Fetal Medicine and the Amniotic Fluid Embolism Foundation whose task was to develop uniform diagnostic criteria for the research reporting of amniotic fluid embolism. These criteria rely on the presence of the classic triad of hemodynamic and respiratory compromise accompanied by strictly defined disseminated intravascular coagulopathy. It is anticipated that limiting research reports involving amniotic fluid embolism to women who meet these criteria will enhance the validity of published data and assist in the identification of risk factors, effective treatments, and possibly useful biomarkers for this condition. A registry has been established in conjunction with the Perinatal Research Branch of the Eunice Kennedy Shriver National Institute of Child Health and Human Development to collect both clinical information and laboratory specimens of women with suspected amniotic fluid embolism in the hopes of identifying unique biomarkers of this condition. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Longitudinal gradient coil optimization in the presence of transient eddy currents.

    PubMed

    Trakic, A; Liu, F; Lopez, H Sanchez; Wang, H; Crozier, S

    2007-06-01

    The switching of magnetic field gradient coils in magnetic resonance imaging (MRI) inevitably induces transient eddy currents in conducting system components, such as the cryostat vessel. These secondary currents degrade the spatial and temporal performance of the gradient coils, and compensation methods are commonly employed to correct for these distortions. This theoretical study shows that by incorporating the eddy currents into the coil optimization process, it is possible to modify a gradient coil design so that the fields created by the coil and the eddy currents combine together to generate a spatially homogeneous gradient that follows the input pulse. Shielded and unshielded longitudinal gradient coils are used to exemplify this novel approach. To assist in the evaluation of transient eddy currents induced within a realistic cryostat vessel, a low-frequency finite-difference time-domain (FDTD) method using the total-field scattered-field (TFSF) scheme was performed. The simulations demonstrate the effectiveness of the proposed method for optimizing longitudinal gradient fields while taking into account the spatial and temporal behavior of the eddy currents.

  16. Balloons Revisited

    ERIC Educational Resources Information Center

    Jeskova, Z.; Featonby, D.; Fekova, V.

    2012-01-01

    Whilst everyone is familiar with the process of blowing up a balloon, few of us have gone further to quantify the actual pressures involved at different stages in the inflation process. This paper seeks to describe experiments to fill some of those gaps and examine some of the apparently anomalous behaviour of connected balloons. (Contains 12…

  17. Unmanned powered balloons

    NASA Technical Reports Server (NTRS)

    Korn, A. O.

    1975-01-01

    In the late 1960's several governmental agencies sponsored efforts to develop unmanned, powered balloon systems for scientific experimentation and military operations. Some of the programs resulted in hardware and limited flight tests; others, to date, have not progressed beyond the paper study stage. Balloon system designs, materials, propulsion units and capabilities are briefly described, and critical problem areas are pointed out which require further study in order to achieve operational powered balloon systems capable of long duration flight at high altitudes.

  18. Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon.

    PubMed

    Iko, Minoru; Tsutsumi, Masanori; Aikawa, Hiroshi; Matsumoto, Yoshihisa; Go, Yoshinori; Nii, Kouhei; Abe, Gorou; Ye, Iwae; Nomoto, Yasuyuki; Kazekawa, Kiyoshi

    2013-01-01

    This retrospective study aimed to compare the effectiveness of the embolization prevention mechanism of two types of embolic protection device (EPD)-a distal protection balloon (DPB) and a distal protection filter (DPF). Subjects were 164 patients scheduled to undergo carotid artery stenting: a DPB was used in 82 cases (DPB group) from April 2007 until June 2010, and a DPF was used in 82 cases (DPF group) from July 2010 to July 2011. Rates of positive findings on postoperative diffusion-weighted imaging (DWI) and stroke incidence were compared. Positive postoperative DWI results were found in 34 cases in the DPB group (41.4 %), but in only 22 cases in the DPF group (26.8 %), and there was only a small significant difference within the DPF group. In the DPB group, there was one case of transient ischemic attack (TIA) (1.2 %) and four cases of brain infarction (2 minor strokes, 2 major strokes; 4.9 %), compared to the DFP group with one case of TIA (1.2 %) and no cases of minor or major strokes. In this study, significantly lower rates of occurrence of DWI ischemic lesions and intraoperative embolization were associated with use of the DPF compared to the DPB.

  19. A Stent-Retrieving into an Aspiration Catheter with Proximal Balloon (ASAP) Technique: A Technique of Mechanical Thrombectomy.

    PubMed

    Goto, Shunsaku; Ohshima, Tomotaka; Ishikawa, Kojiro; Yamamoto, Taiki; Shimato, Shinji; Nishizawa, Toshihisa; Kato, Kyozo

    2018-01-01

    The best technique for the first attempt at mechanical thrombectomy for acute ischemic stroke is a still matter of debate. In this study, we evaluate the efficacy of a stent-retrieving into an aspiration catheter with proximal balloon (ASAP) technique that uses a series of thrombus extraction by withdrawing the stent retriever into the aspiration catheter and continuous aspiration from the aspiration catheter at the first attempt. We performed a retrospective analysis of 42 consecutive patients with acute ischemic stroke caused by occlusions in the anterior circulation who were treated with the ASAP technique at our institution. Preoperative patient characteristic, including age, thrombus location, Alberta Stroke Program Early CT Score, National Institutions of Health Stroke Scale, and time from onset to puncture; postoperative Thrombolysis in Cerebral Infarction score; modified Rankin Scale score after 3 months; time from puncture to recanalization; the number of passes to achieve recanalization; and procedural complications, including intracranial hemorrhage, embolization to new territory, and distal embolization, were assessed. A Thrombolysis in Cerebral Infarction score of 2B or 3 was achieved in 40/42 patients (95.2%). Average time from puncture to the final recanalization was 21.5 minutes. Recanalization was achieved in a single attempt in 31 patients (77.5%). Embolization to new territory was observed in only 2 patients (4.8%); no patient developed distal embolization or intracranial hemorrhage including asymptomatic subarachnoid hemorrhage. Thirty-two patients (76.2%) achieved modified Rankin Scale scores of 0-2 at 3 months postoperatively. Our ASAP technique showed fast recanalization, minimal complications, and good clinical outcomes in this case series. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy for large impacted proximal ureteral calculi: a prospective, randomized study.

    PubMed

    Qi, Shiyong; Li, Yanni; Liu, Xu; Zhang, Changwen; Zhang, Hongtuan; Zhang, Zhihong; Xu, Yong

    2014-09-01

    To evaluate the clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy (POBC-URSL) for large impacted proximal ureteral calculi. 156 patients with impacted proximal ureteral stones ≥1.5 cm in size were randomized to ureteroscopic lithotripsy (URSL), POBC-URSL, and percutaneous nephrolithotomy (PNL) group between May 2010 and May 2013. For URSL, the calculi were disintegrated with the assistance of anti-retropulsion devices. POBC-URSL was performed with the assistance of an 8F percutaneous occlusive balloon catheter. PNL was finished with the combination of an ultrasonic and a pneumatic lithotripter. A flexible ureteroscope and a 200 μm laser fiber were used to achieve stone-free status to a large extent for each group. Variables studied were mean operative time, auxiliary procedure, postoperative hospital stay, operation-related complications, stone clearance rate, and treatment costs. The mean lithotripsy time for POBC-URSL was shorter than URSL, but longer than PNL (42.6±8.9 minutes vs 66.7±15.3 minutes vs 28.1±6.3 minutes, p=0.014). The auxiliary procedure rate and postoperative fever rate for POBC-URSL were significantly lower than URSL and comparable to PNL (p<0.01, p=0.034). POBC-URSL was superior to URSL with regard to the stone clearance rate at 3 days postoperatively, and as good as PNL (98.1% vs 75.0% vs 96.2%, p<0.01). The postoperative hospital stay and hematuria rate were lower in POBC-URSL group than PNL group and similar to URSL group (p=0.016, p<0.01). The treatment costs were lowest in POBC-URSL group ($1205.0±$113.9 vs $1731.7±$208.1 vs $2446.4±$166.4, p=0.004). For large impacted proximal ureteral calculi, POBC-URSL was associated with a higher stone clearance rate, fewer complications and costs. POBC-URSL combined the advantages of URSL and PNL.

  1. Treatment of Intra- and Extracranial Arterial Dissections Using Stents and Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joo, Jin Yang; Ahn, Jung Yong, E-mail: jyahn@cha.ac.kr; Chung, Young Sun

    2005-06-15

    Purpose. To evaluate the safety and efficacy of stent placement for extracranial and intracranial arterial dissections. Methods. Eighteen patients underwent endovascular treatment of carotid and vertebral dissections using intraluminal stent placement. Five patients with arterial dissection were treated, 2 using one insertion of a single stent and 3 using placement of two stents. Patients with a dissecting aneurysm were treated as follows: 7 patients with insertion of one stent, 4 with placement of two stents, and 2 by stent-assisted Guglielmi detachable coil embolization. In the 18 patients in whom stenting was attempted, the overall success in reaching the target lesionmore » was 94.4%. Of the 17 patients treated with stents, stent release and positioning were considered optimal in 16 (94%) and suboptimal in one (6%). In patients who underwent a successful procedure, all parent arteries were preserved. There were no instances of postprocedural ischemic attacks, new neurologic deficits, or new minor or major strokes prior to patient discharge. In follow up, all patients were assessed, using the modified Rankin scale, as functionally improved or of stable clinical status. The reduction in dissection-induced stenosis or pseudoaneurysm, the patency rate obtained at follow-up, and the lack of strokes (ischemic or hemorrhagic) suggest that stent placement offers a viable alternative to complex surgical bypass or reconstructive procedures. The long-term efficacy and durability of stent placement for arterial dissection remain to be determined in a larger series.« less

  2. Systemic Artery to Pulmonary Artery Fistula Associated with Mitral Regurgitation: Successful Treatment with Endovascular Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iwazawa, Jin, E-mail: iwazawa.jin@nissay-hp.or.j; Nakamura, Kenji; Hamuro, Masao

    We present the case of a 60-year-old woman with symptomatic mitral regurgitation caused by a left-to-right shunt via anastomoses consisting of microfistulae, most likely of inflammatory origin, between the right subclavian artery and the right pulmonary artery. The three arteries responsible for fistulous formation, including the internal mammary, thyrocervical, and lateral thoracic arteries, were successfully occluded by transcatheter embolization using superabsorbent polymer microsphere (SAP-MS) particles combined with metallic coils. No complications have been identified following treatment with SAP-MS particles. This approach significantly reduced the patient's mitral regurgitation and she has remained asymptomatic for more than 4 years.

  3. Applying graph theory to protein structures: an atlas of coiled coils.

    PubMed

    Heal, Jack W; Bartlett, Gail J; Wood, Christopher W; Thomson, Andrew R; Woolfson, Derek N

    2018-05-02

    To understand protein structure, folding and function fully and to design proteins de novo reliably, we must learn from natural protein structures that have been characterised experimentally. The number of protein structures available is large and growing exponentially, which makes this task challenging. Indeed, computational resources are becoming increasingly important for classifying and analysing this resource. Here, we use tools from graph theory to define an atlas classification scheme for automatically categorising certain protein substructures. Focusing on the α-helical coiled coils, which are ubiquitous protein-structure and protein-protein interaction motifs, we present a suite of computational resources designed for analysing these assemblies. iSOCKET enables interactive analysis of side-chain packing within proteins to identify coiled coils automatically and with considerable user control. Applying a graph theory-based atlas classification scheme to structures identified by iSOCKET gives the Atlas of Coiled Coils, a fully automated, updated overview of extant coiled coils. The utility of this approach is illustrated with the first formal classification of an emerging subclass of coiled coils called α-helical barrels. Furthermore, in the Atlas, the known coiled-coil universe is presented alongside a partial enumeration of the 'dark matter' of coiled-coil structures; i.e., those coiled-coil architectures that are theoretically possible but have not been observed to date, and thus present defined targets for protein design. iSOCKET is available as part of the open-source GitHub repository associated with this work (https://github.com/woolfson-group/isocket). This repository also contains all the data generated when classifying the protein graphs. The Atlas of Coiled Coils is available at: http://coiledcoils.chm.bris.ac.uk/atlas/app.

  4. Endovascular Treatment of Haemodialysis Arteriovenous Fistula with Drug-Coated Balloon Angioplasty: A Single-Centre Study.

    PubMed

    Lučev, Jernej; Breznik, Silva; Dinevski, Dejan; Ekart, Robert; Rupreht, Mitja

    2018-06-01

    To evaluate the effect of percutaneous transluminal angioplasty (PTA) on haemodialysis fistulas utilising drug-coated balloons with plain balloon vessel preparation (DCB). In the study group, 31 patients (16 men; mean age 62.8 ± 17.2 years) with failing arteriovenous fistulas were treated, with DCB, and compared with a control group (31 patients; 15 men; mean age 67.0 ± 8.44 years), in which only plain balloon PTA was performed. All stenoses were dilated with regular PTA balloons. After achieving haemodynamic success (< 30% residual stenosis), drug-coated balloons were used for drug administration in the study group. The follow-up intervals were 6, 12 and 24 months. Target lesion primary patency, primary assisted patency and secondary patency were compared. The statistical significance was set at 0.05. Target lesion primary patency was compared in both groups and was significantly higher in the study group (DCB) at 6 months (90.3 vs. 61.3%; p = 0.016), 12 months (77.4 vs. 29%; p = 0.0004) as well as 24 months (45.2 vs. 16.1%; p = 0.026). Kaplan-Meier survival curves also showed a significant difference for target lesion primary patency (534.2 vs. 315.7 days; p = 0.0004). There were no significant differences in target lesion primary assisted patency and in secondary patency. However, only 38.7% of patients in the study group were treated twice or more versus 80.6% in the control group (p = 0.002). DCB increases target lesion primary patency during the first 24 months and decreases the rate of reinterventions.

  5. Workflow in interventional radiology: uterine fibroid embolization (UFE)

    NASA Astrophysics Data System (ADS)

    Lindisch, David; Neumuth, Thomas; Burgert, Oliver; Spies, James; Cleary, Kevin

    2008-03-01

    Workflow analysis can be used to record the steps taken during clinical interventions with the goal of identifying bottlenecks and streamlining the procedure efficiency. In this study, we recorded the workflow for uterine fibroid embolization (UFE) procedures in the interventional radiology suite at Georgetown University Hospital in Washington, DC, USA. We employed a custom client/server software architecture developed by the Innovation Center for Computer Assisted Surgery (ICCAS) at the University of Leipzig, Germany. This software runs in a JAVA environment and enables an observer to record the actions taken by the physician and surgical team during these interventions. The data recorded is stored as an XML document, which can then be further processed. We recorded data from 30 patients and found a mean intervention time of 01:49:46 (+/- 16:04) minutes. The critical intervention step, the embolization, had a mean time of 00:15:42 (+/- 05:49) minutes, which was only 15% of the total intervention time.

  6. Prophylactic Embolization of the Cystic Artery Prior to Radioembolization of Liver Malignancies—An Evaluation of Necessity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powerski, Maciej, E-mail: maciej.powerski@med.ovgu.de; Busse, Anke, E-mail: anke.busse@med.ovgu.de; Seidensticker, Max, E-mail: max.seidensticker@med.ovgu.de

    PurposePrior to radioembolization (RE) of hepatic tumors, many centers prophylactically occlude the cystic artery (CA) during evaluation angiography (EVA) to prevent radiation-induced cholecystitis. There is no conclusive evidence for the protective effect of CA embolization and it bears the risk of inducing ischemic cholecystitis. The aim of this study is to evaluate the justification for CA embolization by comparing clinical and morphologic imaging parameters between patients undergoing coil occlusion of the cystic artery (COCA) and those with uncoiled CA (UCCA).Materials and MethodsRetrospective comparison of 37 patients with UCCA versus 68 patients with COCA in terms of clinical findings (CRP, leukocytemore » count, body temperature, upper abdominal pain) and morphologic imaging parameters associated with cholecystitis (gallbladder (GB) wall thickness, free fluid in GB bed, bremsstrahlung SPECT) after EVA, after RE, and at 6-week follow-up.ResultsAt none of the 3 time points (EVA, RE, 6-week follow-up) was there any significant difference in CRP, leukocyte count, body temperature, or upper abdominal pain between the UCCA and COCA group. There was also no significant difference between the two groups with regard to GB wall thickness, fluid in the GB bed, and bremsstrahlung in SPECT. One patient of the UCCA group and two patients of the COCA developed cholecystitis requiring treatment.ConclusionComparison of clinical and imaging findings between patients with and without CA embolization prior to RE identified no predictors of radiogenic or ischemic cholecystitis after RE. Our study provides no evidence for a benefit of prophylactic CA embolization before RE.« less

  7. The development of a computer-assisted instruction system for clinical nursing skills with virtual instruments concepts: A case study for intra-aortic balloon pumping.

    PubMed

    Chang, Ching-I; Yan, Huey-Yeu; Sung, Wen-Hsu; Shen, Shu-Cheng; Chuang, Pao-Yu

    2006-01-01

    The purpose of this research was to develop a computer-aided instruction system for intra-aortic balloon pumping (IABP) skills in clinical nursing with virtual instrument (VI) concepts. Computer graphic technologies were incorporated to provide not only static clinical nursing education, but also the simulated function of operating an expensive medical instrument with VI techniques. The content of nursing knowledge was adapted from current well-accepted clinical training materials. The VI functions were developed using computer graphic technology with photos of real medical instruments taken by digital camera. We wish the system could provide beginners of nursing education important teaching assistance.

  8. A new twist in the coil: functions of the coiled-coil domain of structural maintenance of chromosome (SMC) proteins.

    PubMed

    Matityahu, Avi; Onn, Itay

    2018-02-01

    The higher-order organization of chromosomes ensures their stability and functionality. However, the molecular mechanism by which higher order structure is established is poorly understood. Dissecting the activity of the relevant proteins provides information essential for achieving a comprehensive understanding of chromosome structure. Proteins of the structural maintenance of chromosome (SMC) family of ATPases are the core of evolutionary conserved complexes. SMC complexes are involved in regulating genome dynamics and in maintaining genome stability. The structure of all SMC proteins resembles an elongated rod that contains a central coiled-coil domain, a common protein structural motif in which two α-helices twist together. In recent years, the imperative role of the coiled-coil domain to SMC protein activity and regulation has become evident. Here, we discuss recent advances in the function of the SMC coiled coils. We describe the structure of the coiled-coil domain of SMC proteins, modifications and interactions that are mediated by it. Furthermore, we assess the role of the coiled-coil domain in conformational switches of SMC proteins, and in determining the architecture of the SMC dimer. Finally, we review the interplay between mutations in the coiled-coil domain and human disorders. We suggest that distinctive properties of coiled coils of different SMC proteins contribute to their distinct functions. The discussion clarifies the mechanisms underlying the activity of SMC proteins, and advocates future studies to elucidate the function of the SMC coiled coil domain.

  9. Balloon-Assisted Tracking Use Reduces Radial Artery Access Failure in an Experienced Radial Center and is Feasible During Primary PCI for STEMI.

    PubMed

    Obaid, Daniel; Hailan, Ahmed; Chase, Alexander; Dorman, Stephen; Jenkins, Geraint; Raybould, Adrian; Ramsey, Mark; Thomas, Phillip; Smith, David; Ionescu, Adrian

    2017-07-01

    This prospective study assesses balloon-assisted tracking (BAT) in reducing radial access failure during percutaneous coronary intervention (PCI). Arterial spasm prevents PCI from the radial artery in a small percentage of cases. A total of 2223 consecutive patients undergoing PCI from the radial approach were analyzed. Radial access failure mode and requirement for crossover to femoral access during a 12-month run-in period were compared with the following 14-month period with routine BAT usage. During the 14-month study period, 1334 radial PCIs were attempted. Twenty-six patients switched to femoral at an early stage, while 76 encountered radial spasm and underwent successful BAT in 69 cases (91%), giving a total crossover rate to femoral of 33/1334 (2.5%). Utilizing BAT rather than a femoral puncture reduced our institution's radial-femoral crossover rate from 7.6% to 2.5% (P<.01), which is also significantly lower than the radial-femoral crossover rate in the 12 months before BAT implementation (6.1%; P<.01). Mean procedure times were similar for those requiring BAT compared with conventional radial access (51.3 ± 21.3 min vs 47.9 ± 23.7 min; P=.23), and those crossing straight to femoral (BAT not attempted) (60.7 ± 31.9 min; P=.10). Mean first device/balloon time for the BAT-assisted primary PCI cases (22.6 ± 9.4 min) was similar to cases that had radial difficulties and converted to femoral without attempting BAT (25.8 ± 13.4 min; P=.54). BAT allowed catheter passage despite radial spasm in 91% of cases, significantly reducing the institution's rate of femoral crossover. During radial spasm in primary PCI, using BAT did not delay reperfusion compared with femoral crossover.

  10. Scientific Ballooning in India - Recent Developments

    NASA Astrophysics Data System (ADS)

    Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.

    Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  11. Percutaneous balloon pulmonary valvuloplasty (PBPV) of extreme pulmonary valve stenosis by the use of Accura balloon.

    PubMed

    Sinha, Santosh Kumar; Mishra, Vikas; Razi, Mahmadula; Jha, Mukesh Jitendra

    2017-10-04

    Transcatheter therapy of valvular pulmonary stenosis is one of first catheter interventions facilitating its application in field of structural heart disease and now treatment of choice for significant pulmonary stenosis. Myriads of balloon catheter have been used for this purpose starting from Diamond (Boston Scientific,Natick, MA USA), Marshal (Medi-Tech,Watertown MAUSA), Innoue balloon, Tyshak I and currently Tyshak II. Diameter and length of balloon depend on size of annulus and age group, respectively. Problem with shorter balloon is difficulty in keeping it across the annulus while inflation as it tends to slip distally whereas with longer balloon, potential of tricuspid leak or conduction block as it may impinge on adjacent structures. Potential advantage of Accura balloon over Tyshak balloon lies in its peculiar shape while inflation and variable diameter, making stepwise dilatation possible. Here, we report a case of successful balloon pulmonary valvuloplasty using Accura balloon (Vascular Concept, UK) with little modification of conventional technique. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Comparison of shape memory polymer foam versus bare metal coil treatments in an in vivo porcine sidewall aneurysm model.

    PubMed

    Horn, John; Hwang, Wonjun; Jessen, Staci L; Keller, Brandis K; Miller, Matthew W; Tuzun, Egemen; Hartman, Jonathan; Clubb, Fred J; Maitland, Duncan J

    2017-10-01

    The endovascular delivery of platinum alloy bare metal coils has been widely adapted to treat intracranial aneurysms. Despite the widespread clinical use of this technique, numerous suboptimal outcomes are possible. These may include chronic inflammation, low volume filling, coil compaction, and recanalization, all of which can lead to aneurysm recurrence, need for retreatment, and/or potential rupture. This study evaluates a treatment alternative in which polyurethane shape memory polymer (SMP) foam is used as an embolic aneurysm filler. The performance of this treatment method was compared to that of bare metal coils in a head-to-head in vivo study utilizing a porcine vein pouch aneurysm model. After 90 and 180 days post-treatment, gross and histological observations were used to assess aneurysm healing. At 90 days, the foam-treated aneurysms were at an advanced stage of healing compared to the coil-treated aneurysms and showed no signs of chronic inflammation. At 180 days, the foam-treated aneurysms exhibited an 89-93% reduction in cross-sectional area; whereas coiled aneurysms displayed an 18-34% area reduction. The superior healing in the foam-treated aneurysms at earlier stages suggests that SMP foam may be a viable alternative to current treatment methods. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1892-1905, 2017. © 2016 Wiley Periodicals, Inc.

  13. Hot-Air Ballooning in Physics Teaching.

    ERIC Educational Resources Information Center

    Haugland, Ole Anton

    1991-01-01

    Describes the modern hot-air balloon and the physics of ballooning. Proposes that students construct their own hot-air balloon and presents an experiment calculating the time needed for a balloon to rise to the ceiling of a gymnasium. (MDH)

  14. Optimum designs for superpressure balloons

    NASA Astrophysics Data System (ADS)

    Smith, M. S.; Rainwater, E. L.

    2004-01-01

    The elastica shape is now well known to be the best basic shape for superpressure balloon design. This shape, also known as the pumpkin, or natural shape for balloons, has been well understood since the early 1900s when it was applied to the determination of the shape of descending parachutes. The elastica shape was also investigated in the 1950s when high strength films were used to produce superpressure cylinder balloons. The need for uniform stress distribution in shells of early superpressure balloons led to a long period of the development of spherical superpressure balloons. Not until the late 1970s was the elastica shape revisited for the purpose of the producing superpressure balloons. This paper will review various development efforts in the field of superpressure design and will elaborate on the current state-of-the-art with suggestions for future developments.

  15. A prospective comparison of performance during back-to-back, anterograde manual spiral enteroscopy and double-balloon enteroscopy.

    PubMed

    Despott, Edward J; Murino, Alberto; Bourikas, Leonidas; Nakamura, Masanao; Ramachandra, Vino; Fraser, Chris

    2015-05-01

    Spiral enteroscopy is a recently introduced technology alternative to balloon-assisted enteroscopy for examination of the small bowel. To compare small bowel insertion depths and procedure duration by spiral enteroscopy and double-balloon enteroscopy performed in the same cohort of patients, in immediate succession, using the same method of insertion depth estimation. A prospective, back-to-back comparative study was performed in 15 patients. Spiral enteroscopy procedures were performed first and a tattoo was placed to mark the most distal point. Double-balloon enteroscopy passed the tattoo placed at spiral enteroscopy in 14/15 cases (93%). Median insertion depths for double-balloon enteroscopy and spiral enteroscopy were 265cm and 175cm, respectively (P=0.004). Median time to achieve maximal depth of insertion was significantly shorter for spiral enteroscopy compared with double-balloon enteroscopy (24min vs. 45min, respectively; P=0.0005). However, in 14 patients no differences were found in median time to reach the same insertion depth (P=0.28). Double-balloon enteroscopy achieved significantly greater small bowel insertion depth than spiral enteroscopy. Although overall double-balloon enteroscopy procedure duration was longer, the time taken to reach the same small bowel insertion depth by both spiral enteroscopy and double-balloon enteroscopy was similar. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  16. Flow Past a Descending Balloon

    NASA Technical Reports Server (NTRS)

    Baginski, Frank

    2001-01-01

    In this report, we present our findings related to aerodynamic loading of partially inflated balloon shapes. This report will consider aerodynamic loading of partially inflated inextensible natural shape balloons and some relevant problems in potential flow. For the axisymmetric modeling, we modified our Balloon Design Shape Program (BDSP) to handle axisymmetric inextensible ascent shapes with aerodynamic loading. For a few simple examples of two dimensional potential flows, we used the Matlab PDE Toolbox. In addition, we propose a model for aerodynamic loading of strained energy minimizing balloon shapes with lobes. Numerical solutions are presented for partially inflated strained balloon shapes with lobes and no aerodynamic loading.

  17. Status of the NASA Balloon Program

    NASA Technical Reports Server (NTRS)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-01-01

    The NASA Balloon Program (BP) is examined in an overview of design philosophy, R&D activities, flight testing, and the development of a long-duration balloon for Antarctic use. The Balloon Recovery Program was developed to qualify the use of existing films and to design improved materials and seals. Balloon flights are described for studying the supernova SN1987a, and systems were developed to enhance balloon campaigns including mobile launch vehicles and tracking/data-acquisition systems. The technical approach to long-duration ballooning is reviewed which allows the use of payloads of up to 1350 kg for two to three weeks. The BP is responsible for the development of several candidate polyethylene balloon films as well as design/performance standards for candidate balloons. Specific progress is noted in reliability and in R&D with respect to optimization of structural design, resin blending, and extrusion.

  18. Transvenous embolization of cavernous sinus dural arteriovenous fistulas using detachable coils and Glubran 2 acrylic glue via the inferior petrosal sinus approach.

    PubMed

    Li, Zheng-Ran; Jiang, Zai-Bo; Huang, Ming-Sheng; Zhu, Kang-Shun; Wang, Qing; Shan, Hong

    2010-12-01

    To describe the technique, efficacy, and safety of transvenous embolisation (TVE) of cavernous sinus arteriovenous fistulas (CSDAVFs) via the inferior petrosal sinus (IPS) with detachable coils and acrylic glue. Spontaneous unilateral CSDAVFs were confirmed by cerebral angiography in eight patients, with angiographic patency of the ipsilateral IPS in three and angiographic non-visualisation of the ipsilateral IPS in five. There were two patients with complete occlusion of the ipsilateral internal jugular vein (IJV). TVE with detachable coils and acrylic glue were performed through a femoral vein and an IPS approach. TVE viaipsilateral IPS was successfully performed in all eight patients in our group. The number of detachable coils for each patient ranged from 2 to 8 (mean, 5.0). Angiography immediately after TVE showed complete occlusion of the CSCAVFs in seven patients and nearly complete occlusion in one. Complete recovery of clinical symptoms was achieved in all eight patients. No recurrence of clinical symptoms was observed at follow-up. Transvenous embolisation via an IPS approach is a highly efficient and safe treatment for CSDAVFs. Embolisation with a combination of coils and acrylic glue may help to achieve complete occlusion of fistulas with fewer coils.

  19. Computational assessment of folding energy landscapes in heterodimeric coiled coils.

    PubMed

    André, Ingemar; Bjelic, Sinisa

    2018-07-01

    The coiled coil structural motif consists of alpha helices supercoiling around each other to form staggered knobs-into-holes packing. Such structures are deceptively simple, especially as they often can be described with parametric equations, but are known to exist in various conformations. Even the simplest systems, consisting of 2 monomers, can assemble into a wide range of states. They can form canonical as well as noncanonical coiled coils, be parallel or antiparallel, where helices associate with different degrees of shift, tilt, and rotation. Here, we investigate the energy landscape of heterodimeric coiled coils by carrying out de novo folding simulations starting from amino acid sequence. We folded a diverse set of 22 heterodimers and demonstrate that the approach is capable of identifying the atomic details in the experimental structure in the majority of cases. Our methodology also enables exploration of alternative states that can be accessible in solution beyond the experimentally determined structure. For many systems, we observe folding energy landscapes with multiple energy minima and several isoenergetic states. By comparing coiled coils from single domains and those extracted from larger proteins, we find that standalone coiled coils have deeper energy wells at the experimentally determined conformation. By folding the competing homodimeric states in addition to the heterodimers, we observe that the structural specificity towards the heteromeric state is often small. Taken together, our results demonstrate that de novo folding simulations can be a powerful tool to characterize structural specificity of coiled coils when coupled to assessment of energy landscapes. © 2018 Wiley Periodicals, Inc.

  20. Scientific ballooning in India Recent developments

    NASA Astrophysics Data System (ADS)

    Manchanda, R. K.

    Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  1. Crystal Structure of a Coiled-Coil Domain from Human ROCK I

    PubMed Central

    Tu, Daqi; Li, Yiqun; Song, Hyun Kyu; Toms, Angela V.; Gould, Christopher J.; Ficarro, Scott B.; Marto, Jarrod A.; Goode, Bruce L.; Eck, Michael J.

    2011-01-01

    The small GTPase Rho and one of its targets, Rho-associated kinase (ROCK), participate in a variety of actin-based cellular processes including smooth muscle contraction, cell migration, and stress fiber formation. The ROCK protein consists of an N-terminal kinase domain, a central coiled-coil domain containing a Rho binding site, and a C-terminal pleckstrin homology domain. Here we present the crystal structure of a large section of the central coiled-coil domain of human ROCK I (amino acids 535–700). The structure forms a parallel α-helical coiled-coil dimer that is structurally similar to tropomyosin, an actin filament binding protein. There is an unusual discontinuity in the coiled-coil; three charged residues (E613, R617 and D620) are positioned at what is normally the hydrophobic core of coiled-coil packing. We speculate that this conserved irregularity could function as a hinge that allows ROCK to adopt its autoinhibited conformation. PMID:21445309

  2. [METABOLIC PREVENTION OF FAT EMBOLISM.

    PubMed

    Yakovlev, A Yu; Pevnev, A A; Nikol'skiy, V O; Galanina, T A; Prokin, E G; Kalachev, S A; Ryabikov, D V

    2016-07-01

    to study the effect of solution with methionine "Remaxol" on metabolic disorders andfat embolism developing in severe combined trauma. 544 patient with severe skeletal trauma were undergone to a prospective study of dynamics of fat embolism syndrome development depending on the inclusion in the program of infusion therapy drug "Remaxol". The dynamics of lactate, glucose, free fatty acids, globularia and the incidence offat embolism syndrome were analyzed. Corrective action drug with methionine "Remaxol" on hyperglycemia, hyperlactatemia, hyperlipemia and de- crease circulation offat globules, which is reflected in the decrease in the frequency of development offat embolism syndrome was identified. One of the proposed mechanisms reduce the risk offat embolism development is assumed restoration of endogenous carnitine synthesis with methionine and transport offree fatty acids in the cell and their subsequent inclusion in metabolic processes.

  3. A case of an unruptured hepatic aneurysm on the common hepatic artery at the junction of the gastroduodenal and proper hepatic arteries treated with transcatheter arterial embolization.

    PubMed

    Imai, Yusuke; Hirooka, Masashi; Koizumi, Yohei; Nakamura, Yoshiko; Watanabe, Takao; Yoshida, Osamu; Tokumoto, Yoshio; Takeshita, Eiji; Abe, Masanori; Hiasa, Yoichi

    2017-01-01

    Hepatic aneurysms are rare, but can prove fatal once they rupture. Transcatheter arterial embolization (TAE) is performed as a prophylactic treatment. The position of the aneurysm determines the degree of difficulty of TAE. Maintaining blood flow to the liver can become difficult, particularly when the aneurysm is at an arterial junction. The patient was a 72-year-old man diagnosed with a hepatic aneurysm. The aneurysm was situated on the common hepatic artery at the junction of the gastroduodenal and proper hepatic arteries. TAE was performed with framing, followed by coil embolization. Blood flow to the liver was maintained via the gastroduodenal artery. Appropriate framing is important for safe and efficient TAE.

  4. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    NASA Technical Reports Server (NTRS)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  5. Optimization of Coil Element Configurations for a Matrix Gradient Coil.

    PubMed

    Kroboth, Stefan; Layton, Kelvin J; Jia, Feng; Littin, Sebastian; Yu, Huijun; Hennig, Jurgen; Zaitsev, Maxim

    2018-01-01

    Recently, matrix gradient coils (also termed multi-coils or multi-coil arrays) were introduced for imaging and B 0 shimming with 24, 48, and even 84 coil elements. However, in imaging applications, providing one amplifier per coil element is not always feasible due to high cost and technical complexity. In this simulation study, we show that an 84-channel matrix gradient coil (head insert for brain imaging) is able to create a wide variety of field shapes even if the number of amplifiers is reduced. An optimization algorithm was implemented that obtains groups of coil elements, such that a desired target field can be created by driving each group with an amplifier. This limits the number of amplifiers to the number of coil element groups. Simulated annealing is used due to the NP-hard combinatorial nature of the given problem. A spherical harmonic basis set up to the full third order within a sphere of 20-cm diameter in the center of the coil was investigated as target fields. We show that the median normalized least squares error for all target fields is below approximately 5% for 12 or more amplifiers. At the same time, the dissipated power stays within reasonable limits. With a relatively small set of amplifiers, switches can be used to sequentially generate spherical harmonics up to third order. The costs associated with a matrix gradient coil can be lowered, which increases the practical utility of matrix gradient coils.

  6. Embolization of Acute Nonvariceal Upper Gastrointestinal Hemorrhage Resistant to Endoscopic Treatment: Results and Predictors of Recurrent Bleeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loffroy, Romaric, E-mail: romaric.loffroy@yahoo.fr; Rao, Pramod; Ota, Shinichi

    2010-12-15

    Acute nonvariceal upper gastrointestinal (UGI) hemorrhage is a frequent complication associated with significant morbidity and mortality. The most common cause of UGI bleeding is peptic ulcer disease, but the differential diagnosis is diverse and includes tumors; ischemia; gastritis; arteriovenous malformations, such as Dieulafoy lesions; Mallory-Weiss tears; trauma; and iatrogenic causes. Aggressive treatment with early endoscopic hemostasis is essential for a favorable outcome. However, severe bleeding despite conservative medical treatment or endoscopic intervention occurs in 5-10% of patients, requiring surgery or transcatheter arterial embolization. Surgical intervention is usually an expeditious and gratifying endeavor, but it can be associated with high operativemore » mortality rates. Endovascular management using superselective catheterization of the culprit vessel, < sandwich> occlusion, or blind embolization has emerged as an alternative to emergent operative intervention for high-risk patients and is now considered the first-line therapy for massive UGI bleeding refractory to endoscopic treatment. Indeed, many published studies have confirmed the feasibility of this approach and its high technical and clinical success rates, which range from 69 to 100% and from 63 to 97%, respectively, even if the choice of the best embolic agent among coils, cyanaocrylate glue, gelatin sponge, or calibrated particles remains a matter of debate. However, factors influencing clinical outcome, especially predictors of early rebleeding, are poorly understood, and few studies have addressed this issue. This review of the literature will attempt to define the role of embolotherapy for acute nonvariceal UGI hemorrhage that fails to respond to endoscopic hemostasis and to summarize data on factors predicting angiographic and embolization failure.« less

  7. Coronary bypass flow during use of intraaortic balloon pumping and left ventricular assist device.

    PubMed

    Tedoriya, T; Kawasuji, M; Sakakibara, N; Takemura, H; Watanabe, Y; Hetzer, R

    1998-08-01

    Intraaortic balloon pumping (IABP) and left ventricular assist device (LVAD) are used for left ventricular support when low cardiac output occurs after a coronary bypass operation for serious coronary artery disease. There are hemodynamic differences in blood flow in various kinds of coronary artery bypass grafts, caused by their inherent physiologic characteristics. The hemodynamic effects of left ventricular assistance with IABP and LVAD on blood flow through various coronary artery bypass grafts were investigated. An ascending aorta-coronary bypass graft (ACB), an internal thoracic artery, and a descending aorta-coronary bypass graft were anastomosed to the left anterior descending coronary artery in a canine model. In this experimental model, the blood flow to the same coronary bed in the three types of grafts could be evaluated. Blood flow in the left anterior descending coronary artery through the three types of coronary bypass grafts was studied in this model during or in the absence of ventricular assistance. In the control study, the systolic blood flow did not differ among the three types of grafts, but the diastolic flow decreased in the following order: with the ACB, the internal thoracic artery, and the descending aorta-coronary bypass graft. The systolic flow during IABP and LVAD was similar to the control flows. Use of IABP increased the diastolic flow by 75.3%+/-12.4% of the control value in the ACB, 37.9%+/-25.0% in the internal thoracic artery, and 21.2%+/-11.4% in the descending aorta-coronary bypass graft. The LVAD increased the diastolic flow by 97.7%+/-18.7% of the control value in the ACB, 64.5%+/-25.7% in the internal thoracic artery, and 63.0%+/-27.9% in the descending aorta-coronary bypass graft. The diastolic blood flows in the left anterior descending coronary artery and the three types of grafts were significantly greater with IABP than the control values, and significantly greater with LVAD than with IABP and the control values. The

  8. A stress index model for ascending balloons

    NASA Technical Reports Server (NTRS)

    Smith, I. S.

    1986-01-01

    Attention is given to the development on the part of NASA of a simplified stress 'index' model to establish the relative stress magnitudes along a balloon's gore position as a function of altitude. Application of this model to several hundred balloon flights showed a good correlation between balloon failure rate and stress 'index' level. This model can be used during the balloon design process to lower the levels of stress in the balloon. By increasing the wall thickness of the balloon, adding caps, lengthening caps, or using external caps, lower stress can be accomplished. As a result, in January 1985, the NASA Balloon Program established a stress index specification to limit the design and flight stresses for NASA balloons.

  9. A Synthetic Coiled-Coil Interactome Provides Heterospecific Modules for Molecular Engineering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reinke, Aaron W.; Grant, Robert A.; Keating, Amy E.

    2010-06-21

    The versatile coiled-coil protein motif is widely used to induce and control macromolecular interactions in biology and materials science. Yet the types of interaction patterns that can be constructed using known coiled coils are limited. Here we greatly expand the coiled-coil toolkit by measuring the complete pairwise interactions of 48 synthetic coiled coils and 7 human bZIP coiled coils using peptide microarrays. The resulting 55-member protein 'interactome' includes 27 pairs of interacting peptides that preferentially heteroassociate. The 27 pairs can be used in combinations to assemble sets of 3 to 6 proteins that compose networks of varying topologies. Of specialmore » interest are heterospecific peptide pairs that participate in mutually orthogonal interactions. Such pairs provide the opportunity to dimerize two separate molecular systems without undesired crosstalk. Solution and structural characterization of two such sets of orthogonal heterodimers provide details of their interaction geometries. The orthogonal pair, along with the many other network motifs discovered in our screen, provide new capabilities for synthetic biology and other applications.« less

  10. Functional Investigation of the Plant-Specific Long Coiled-Coil Proteins PAMP-INDUCED COILED-COIL (PICC) and PICC-LIKE (PICL) in Arabidopsis thaliana

    PubMed Central

    Venkatakrishnan, Sowmya; Mackey, David; Meier, Iris

    2013-01-01

    We have identified and characterized two Arabidopsis long coiled-coil proteins PAMP-INDUCED COILED-COIL (PICC) and PICC-LIKE (PICL). PICC (147 kDa) and PICL (87 kDa) are paralogs that consist predominantly of a long coiled-coil domain (expanded in PICC), with a predicted transmembrane domain at the immediate C-terminus. Orthologs of PICC and PICL were found exclusively in vascular plants. PICC and PICL GFP fusion proteins are anchored to the cytoplasmic surface of the endoplasmic reticulum (ER) membrane by a C-terminal transmembrane domain and a short tail domain, via a tail-anchoring mechanism. T-DNA-insertion mutants of PICC and PICL as well as the double mutant show an increased sensitivity to the plant abiotic stress hormone abscisic acid (ABA) in a post-germination growth response. PICC, but not PICL gene expression is induced by the bacterial pathogen-associated molecular pattern (PAMP) flg22. T-DNA insertion alleles of PICC, but not PICL, show increased susceptibility to the non-virulent strain P. syringae pv. tomato DC3000 hrcC, but not to the virulent strain P. syringae pv. tomato DC3000. This suggests that PICC mutants are compromised in PAMP-triggered immunity (PTI). The data presented here provide first evidence for the involvement of a plant long coiled-coil protein in a plant defense response. PMID:23451199

  11. Abnormal placental invasion--a novel approach to treatment case report and review.

    PubMed

    Ophir, Ella; Singer-Jordan, Jonathan; Odeh, Marwan; Hirch, Yael; Maksimovsky, Olga; Shaider, Oleg; Yvry, Simon; Solt, Ido; Bornstein, Jacob

    2009-12-01

    The incidence of abnormal placental invasion has increased 10-fold in the past 50 years, reflecting the increased number of cesarean sections performed. Management relies on accurate early diagnosis with appropriate perioperative multidisciplinary planning to anticipate and avoid massive obstetric hemorrhage at delivery. Women at risk should plan to deliver at an institution with appropriate expertise and resources for managing this condition. We report a case of placenta increta management comprising preoperative placement of a pelvic artery balloon catheter, prophylactic balloon occlusion after delivery of the fetus, and embolization-assisted resection of the invaded uterine wall. We review incidence, methods of prenatal diagnosis, risk factors, and management of abnormally invasive placenta.

  12. Numerical modeling process of embolization arteriovenous malformation

    NASA Astrophysics Data System (ADS)

    Cherevko, A. A.; Gologush, T. S.; Petrenko, I. A.; Ostapenko, V. V.

    2017-10-01

    Cerebral arteriovenous malformation is a difficult, dangerous, and most frequently encountered vascular failure of development. It consists of vessels of very small diameter, which perform a discharge of blood from the artery to the vein. In this regard it can be adequately modeled using porous medium. Endovascular embolization of arteriovenous malformation is effective treatment of such pathologies. However, the danger of intraoperative rupture during embolization still exists. The purpose is to model this process and build an optimization algorithm for arteriovenous malformation embolization. To study the different embolization variants, the initial-boundary value problems, describing the process of embolization, were solved numerically by using a new modification of CABARET scheme. The essential moments of embolization process were modeled in our numerical experiments. This approach well reproduces the essential features of discontinuous two-phase flows, arising in the embolization problems. It can be used for further study on the process of embolization.

  13. Private and Commercial Pilot: Free Balloon: Flight Test Guide (Part 61 Revised).

    ERIC Educational Resources Information Center

    Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.

    The flight test guide has been prepared to assist the applicant and his instructor in preparing for the private pilot or commercial pilot certificate with a lighter-than-air category and free balloon class rating. It contains information and guidance concerning the pilot operations, procedures, and maneuvers relevant to the flight test: layout and…

  14. Successful Removal of Malpositioned Chest Drain Within the Liver by Embolization of the Transhepatic Track

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tait, Paul; Waheed, Umeer; Bell, Suzanne, E-mail: drsuzy29@hotmail.co

    2009-07-15

    The insertion of a chest drain catheter for the management of a pneumothorax in an 82-year-old woman resulted in the unusual complication of liver penetration. The position of the drain was assessed by contrast-enhanced computed tomographic scan. Because the patient was hemodynamically stable and no damage to major vessels was seen on computed tomographic scan, the patient was treated in a nonoperative manner. A procedure was performed under controlled conditions using techniques used during transhepatic liver biopsies but with the addition of a balloon catheter. Embolization of the liver track was performed during chest drain removal. The drain was successfullymore » removed without the complication of bleeding in a patient unsuitable for a general anesthetic.« less

  15. Changing Paradigms in the Endovascular Management of Ruptured Anterior Communicating Artery Aneurysms.

    PubMed

    Moon, Karam; Park, Min S; Albuquerque, Felipe C; Levitt, Michael R; Mulholland, Celene B; McDougall, Cameron G

    2017-10-01

    Approximately 17% of ruptured anterior communicating artery (ACoA) aneurysms were deemed unsuitable for coil embolization during the Barrow Ruptured Aneurysm Trial (BRAT), most commonly due to unfavorable dome-to-neck ratio or small size. To compare patients treated by coil embolization for ruptured ACoA aneurysms during the trial to those treated after the trial to determine whether advances in endovascular techniques have allowed for effective treatment of these lesions. All cases of ruptured ACoA aneurysms treated by endovascular modalities during BRAT (2003-2007) and post-BRAT (2007-2012) were reviewed for patient and aneurysm characteristics, treatment types, and clinical and angiographic outcomes at 3-yr or last follow-up. The BRAT ACoA cohort included 39 patients treated with coiling (excluding those crossed over to clipping). The post-BRAT cohort included 93 patients who were significantly older (mean age, 59.5 vs 52.8 yr, P = .005) than the BRAT cohort; there were no significant cohort differences in sex, Hunt and Hess grade, or mean aneurysm size. The use of balloon remodeling was significantly higher in the post-BRAT cohort (31.2% [29/93] vs 5.1% [2/39], P = .001), as was the proportion of wide-necked aneurysms treated (66.7% [62/93] vs 30.8% [12/39], P < .001). There was no significant difference in clinical outcome or retreatment rate between the 2 cohorts (P = .90 and P = .48, respectively). ACoA lesions thought unamenable to endovascular therapy in an earlier randomized trial are now successfully coiled with increased use of adjunctive techniques, without sacrificing patient outcome or treatment durability. Copyright © 2016 by the Congress of Neurological Surgeons.

  16. Embolization Therapy for Traumatic Splenic Lacerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dasgupta, Niloy; Matsumoto, Alan H., E-mail: ahm4d@virginia.edu; Arslan, Bulent

    Purpose: This study was designed to evaluate the clinical success, complications, and transfusion requirements based on the location of and agents used for splenic artery embolization in patients with splenic trauma. Methods: A retrospective study was performed of patients with splenic trauma who underwent angiography and embolization from September 2000 to January 2010 at a level I trauma center. Electronic medical records were reviewed for demographics, imaging data, technical aspects of the procedure, and clinical outcomes. Results: Fifty patients were identified (34 men and 16 women), with an average age of 48 (range, 16-80) years. Extravasation was seen on initialmore » angiography in 27 (54%) and was absent in 23 (46%). All 27 patients with extravasation were embolized, and 18 of 23 (78.2%) without extravasation were embolized empirically. Primary clinical success was similar (>75%) across all embolization locations, embolic agents, and grades of laceration treated. Of 45 patients treated, 9 patients (20%) were embolized in the main splenic artery, 34 (75.6%) in the splenic hilum, and 2 (4.4%) were embolized in both locations. Partial splenic infarctions developed in 47.3% treated in the splenic hilum compared with 12.5% treated in the main splenic artery. There were four (8.9%) mortalities: two occurred in patients with multiple critical injuries and two from nonbleeding etiologies. Conclusions: Embolization of traumatic splenic artery injuries is safe and effective, regardless of the location of treatment. Embolization in splenic hilar branches may have a higher incidence of infarction. The grade of laceration and agents used for embolotherapy did not impact the outcomes.« less

  17. Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation

    PubMed Central

    Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R.

    2015-01-01

    Abstract The intra‐aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre‐, intra‐, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi‐recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra‐aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. PMID:25959284

  18. Launching Garbage-Bag Balloons.

    ERIC Educational Resources Information Center

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  19. Triple Halo Coil: Development and Comparison with Other TMS Coils

    NASA Astrophysics Data System (ADS)

    Rastogi, Priyam; Hadimani, Ravi; Jiles, David

    Transcranial Magnetic Stimulation (TMS) is a non-invasive stimulation technique that can be used for the treatment of various neurological disorders such as Parkinson's Disease, PTSD, TBI and anxiety by regulating synaptic activity. TMS is FDA approved for the treatment of major depressive disorder. There is a critical need to develop deep TMS coils that can stimulate deeper regions of the brain without excessively stimulating the cortex in order to provide an alternative to surgical methods. We have developed a novel multi-coil configuration called ``Triple Halo Coil'' (THC) that can stimulate deep brain regions. Investigation of induced electric and magnetic field in these regions have been achieved by computer modelling. Comparison of the results due to THC configuration have been conducted with other TMS coils such as ``Halo Coil'', circular coil and ``Figure of Eight'' coil. There was an improvement of more than 15 times in the strength of magnetic field, induced by THC configuration at 10 cm below the vertex of the head when compared with the ``Figure of Eight'' coil alone. Carver Charitable Trust.

  20. Biomaterials Made from Coiled-Coil Peptides.

    PubMed

    Conticello, Vincent; Hughes, Spencer; Modlin, Charles

    The development of biomaterials designed for specific applications is an important objective in personalized medicine. While the breadth and prominence of biomaterials have increased exponentially over the past decades, critical challenges remain to be addressed, particularly in the development of biomaterials that exhibit highly specific functions. These functional properties are often encoded within the molecular structure of the component molecules. Proteins, as a consequence of their structural specificity, represent useful substrates for the construction of functional biomaterials through rational design. This chapter provides an in-depth survey of biomaterials constructed from coiled-coils, one of the best-understood protein structural motifs. We discuss the utility of this structurally diverse and functionally tunable class of proteins for the creation of novel biomaterials. This discussion illustrates the progress that has been made in the development of coiled-coil biomaterials by showcasing studies that bridge the gap between the academic science and potential technological impact.

  1. Suicide by Intentional Air embolism.

    PubMed

    Simon, Gábor; Rácz, Evelin; Mayer, Mátyás; Heckmann, Veronika; Tóth, Dénes; Kozma, Zsolt

    2017-05-01

    Venous air embolism occurs when air enters the venous system. The main causes of venous air embolism include medical procedures, neck and head trauma, and injuries of the genitals. Self-induced suicidal (and intentional) air embolism is extremely rare. The authors report a rare case of a suicidal air embolism committed using a self-made tool composed of a plastic bottle and an infusion set, injecting nearly 2000 mL of air into the cubital vein. The toxicological analysis suggested that midazolam, together with air, was also injected into the circulation using the same bottle and infusion set. © 2016 American Academy of Forensic Sciences.

  2. Effectiveness of collateral vein embolization for salvage of immature native arteriovenous fistulas.

    PubMed

    Ahmed, Osman; Patel, Mikin; Ginsburg, Michael; Jilani, Danial; Funaki, Brian

    2014-12-01

    To investigate the value of collateral vein embolization (CVE) as a salvage treatment for nonmaturing native arteriovenous fistulae (AVFs) in patients requiring hemodialysis. A total of 49 patients undergoing CVE (N = 65) for immature native AVFs at a single institution were reviewed. The study included 42 patients treated by 56 embolizations. Average fistula age at time of intervention was 18.2 weeks. Each patient underwent angiographic evaluation for fistula immaturity, with clinical success defined by initiation of single-session hemodialysis through the native fistula. Fistula maturity was achieved in 32 of 42 patients (76.2%). No major complications occurred. Average time from CVE to fistula maturity was 38.4 days. Angioplasty done with CVE was found in a statistically higher percentage of patients with fistula success versus failure (31.3% vs 8.3%; P = .039). Radiocephalic fistulae were seen in a higher percentage of fistula failures compared with successes, but the results were not statistically significant (83.3% vs 59.4%; P = .054). Thirty-four patients underwent CVE without angioplasty, which resulted in successful fistula maturation in 22 cases (64.7%). Radiocephalic fistulae were again seen in a higher percentage of fistula failures compared with successes, but the findings did not meet statistical significance (81.8% vs 54.5%; P = .052). Coil embolization of competing collateral vessels as a salvage treatment for nonfunctioning autologous AVFs is a viable treatment option in the majority of patients. Patients with radiocephalic fistulae may be at higher risk for primary fistula failure, but the present data are inconclusive. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  3. Mechanical properties of ANTRIX balloon film and fabrication of single cap large volume balloons

    NASA Astrophysics Data System (ADS)

    Suneel Kumar, B.; Sreenivasan, S.; Subba Rao, J. V.; Manchanda, R. K.

    2008-11-01

    The zero pressure plastic balloons used for high altitude studies are generally made from polyethylene material. Tensile properties of the thin film polymer are the key parameters for material selection due to extremely low temperature of -90 °C encountered by the balloons in the tropopause region during the ascent at equatorial latitudes. The physical and structural properties of the material determine the uniformity of the stress distribution over the entire shell. Load stresses from the suspended load propagate via load tapes heat sealed along with the gore seals as per the balloon design. A balance between this heat seal strength and the film strength is a desirable property of the basic resin in terms of the bubble strength, gauge uniformity, and long-term storage properties. In addition, the design of the top shell of the balloon and its stress distribution play an important role since only a fraction of the balloon is deployed during the filling operation and the ascent. In this paper we describe the mechanical properties of the 'ANTRIX' film developed by us and the optimized design of single cap balloons, which have been successfully used in our experiments over the past 5 years.

  4. Coil Welding Aid

    NASA Technical Reports Server (NTRS)

    Wiesenbach, W. T.; Clark, M. C.

    1983-01-01

    Positioner holds coil inside cylinder during tack welding. Welding aid spaces turns of coil inside cylinder and applies contact pressure while coil is tack-welded to cylinder. Device facilitates fabrication of heat exchangers and other structures by eliminating hand-positioning and clamping of individual coil turns.

  5. Jejunal varices after choledochojejunostomy treated with laparotomic transcatheter variceal embolization.

    PubMed

    Waguri, Nobuo; Azumi, Rie; Sugimura, Kazuhito; Arao, Yoshihisa; Ikarashi, Shunzo; Sakai, Norihiro; Ogawa, Masahiro; Osaki, Akihiko; Sato, Munehiro; Aiba, Tsuneo; Yoneyama, Osamu; Furukawa, Koichi; Igarashi, Kentarou

    2016-01-01

    Portal hypertension induces collateral shunt formation between the portal and systemic circulation, decompressing the elevated portal pressure. Ectopic varices outside of the gastroesophageal region, such as jejunal varices, are rare conditions. This report describes the successful embolization of ruptured jejunal varices resulting from an extrahepatic portal obstruction. A 62-year-old man was admitted to our hospital with recurrent massive gastrointestinal bleeding. Fourteen months earlier, he had undergone a choledochojejunostomy and pancreatic cystojejunostomy for bile duct stenosis with an enlarged pancreatic pseudocyst due to severe chronic pancreatitis. Contrast-enhanced computed tomography showed jejunal intramural dilated vessels close to the choledochojejunal anastomosis, but extravasation was not observed. Due to the lack of a rapid definitive diagnosis, the patient required massive blood transfusions. Hemorrhagic scintigraphy using 99m Tc-HSAD finally identified the site of the hemorrhage. Angiography and double-balloon endoscopy revealed the anastomotic jejunal varices to be the result of an extrahepatic portal obstruction. Laparotomic transcatheter variceal embolization with microcoils was successful in halting the refractory gastrointestinal bleeding. This surgery preserved hepatopetal portal venous flow by another route, and no complications were observed. At present, 4 years post-surgery, there has been no recurrence of gastrointestinal hemorrhage. The development of jejunal varices is often associated with postoperative adhesions. Some patients with a history of hepatico- or choledochojejunostomy may experience portal hypertension resulting from extrahepatic portal obstruction, leading to the formation of jejunal varices as hepatopetal portal collaterals. The choice of therapy in each patient should be based on the individual hemodynamics of the ectopic varices.

  6. Crystal structure of a designed, thermostable, heterotrimeric coiled coil.

    PubMed Central

    Nautiyal, S.; Alber, T.

    1999-01-01

    Electrostatic interactions are often critical for determining the specificity of protein-protein complexes. To study the role of electrostatic interactions for assembly of helical bundles, we previously designed a thermostable, heterotrimeric coiled coil, ABC, in which charged residues were employed to drive preferential association of three distinct, 34-residue helices. To investigate the basis for heterotrimer specificity, we have used multiwavelength anomalous diffraction (MAD) analysis to determine the 1.8 A resolution crystal structure of ABC. The structure shows that ABC forms a heterotrimeric coiled coil with the intended arrangement of parallel chains. Over half of the ion pairs engineered to restrict helix associations were apparent in the experimental electron density map. As seen in other trimeric coiled coils, ABC displays acute knobs-into-holes packing and a buried anion coordinated by core polar amino acids. These interactions validate the design strategy and illustrate how packing and polar contacts determine structural uniqueness. PMID:10210186

  7. Percutaneous Mitral Valve Dilatation: Single Balloon versus Double Balloon - A Finite Element Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schievano, Silvia; Kunzelman, Karyn; Nicosia, Mark

    2009-01-01

    Background: Percutaneous mitral valve (MV) dilatation is performed with either a single balloon (SB) or double balloon (DB) technique. The aim of this study was to compare the two balloon system results using the finite element (FE) method. Methods and Results: An established FE model of the MV was modified by fusing the MV leaflet edges at commissure level to simulate a stenotic valve (orifice area=180mm2). A FE model of a 30mm SB (low-pressure, elastomeric balloon) and an 18mm DB system (high-pressure, non-elastic balloon) was created. Both SB and DB simulations resulted in splitting of the commissures and subsequent stenosismore » dilatation (final MV area=610mm2 and 560mm2 respectively). Stresses induced by the two balloon systems varied across the valve. At the end of inflation, SB showed higher stresses in the central part of the leaflets and at the commissures compared to DB simulation, which demonstrated a more uniform stress distribution. The higher stresses in the SB analysis were due to the mismatch of the round balloon shape with the oval mitral orifice. The commissural split was not easily accomplished with the SB due to its high compliance. The high pressure applied to the DB guaranteed the commissural split even when high forces were required to break the commissure welds. Conclusions: The FE model demonstrated that MV dilatation can be accomplished by both SB and DB techniques. However, the DB method resulted in higher probability of splitting of the fused commissures and less damage caused to the MV leaflets by overstretching.« less

  8. Technologies developed by CNES balloon team

    NASA Astrophysics Data System (ADS)

    Sosa-Sesma, Sergio; Charbonnier, Jean-Marc; Deramecourt, Arnaud

    CNES balloon team develops and operates all the components of this kind of vehicle: it means envelope and gondola. This abstract will point out only developments done for envelope. Nowadays CNES offers to scientists four types of envelops that cover a large range of mission demands. These envelops are: 1. Zero pressure balloons: Size going from 3,000m3 to 600,000m3, this kind of envelop is ideal for short duration flights (a few hours) but if we use an intelligent management of ballast consumption and if we chose the best launch site, it is possible to perform medium duration flights (10/20 days depending on the ballast on board). Flight train mass starts at 50kg for small balloons and reach 1000kg for larger ones. Zero pressure balloons are inflated with helium gas. 2. Super pressure balloons: Diameter going from 2.5m to 12m, this kind of envelop is ideal for long duration flights (1 to 6 months). Flight train is inside the envelop for small balloons, it means 2.5 diameter meters which is usually called BPCL (Super pressure balloon for Earth boundary layer) and it is about 3kg of mass. Larger ones could lift external flight trains about 50kg of mass. Super pressure balloons are inflated with helium gas. 3. MIR balloons: Size going from 36,000m3 to 46,000m3. Ceiling is reach with helium gas but after three days helium is no longer present inside and lift force is produced by difference of temperature between air inside and air of atmosphere. Flight trains must not be over 50kg. 4. Aero Clipper balloons: A concept to correlate measurements done in oceans and in nearest layers of atmosphere simultaneously. Flight train is made by a "fish" that drags inside water and an atmospheric gondola few meters above "fish", both pushed by a balloon which profits of the wind force. Materials used for construction and assembling depend on balloon type; they are usually made of polyester or polyethylene. Thickness varies from 12 micrometers to 120 micrometers. Balloon assembling

  9. Aneurysm of an Anomalous Systemic Artery Supplying the Normal Basal Segments of the Left Lower Lobe: Endovascular Treatment with the Amplatzer Vascular Plug II and Coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Canyigit, Murat, E-mail: mcanyigit@yahoo.com; Gumus, Mehmet; Kilic, Evrim

    2011-02-15

    An anomalous systemic artery originating from the descending thoracic aorta supplying the normal basal segments of the lower lobe of the left lung without sequestration is a rare congenital anomaly. The published surgical treatments include lobectomy, segmentectomy, anastomosis, and ligation. In addition, endovascular treatment with coils has been reported. A second-generation occluder, the Amplatzer Vascular Plug II (AVP II), has a central plug and two occlusion disks and a finer, more densely woven nitinol wire, thus enabling faster embolization. This published case is the first successful occlusion of an aneurysm of an anomalous systemic artery with the AVP II andmore » fibered coils, with 10 months of follow-up.« less

  10. Coadjuvant Treatment of Vasospasm in Ruptured Unsecured Cerebral Aneurysms with Aggressive Angioplasty, Intra-Arterial Nimodipine, and Aneurysm Embolization.

    PubMed

    Chen, Ching-Chang; Yi-Chou Wang, Alvin; Chen, Chun-Ting; Hsieh, Po-Chuan

    2018-05-16

    Vasospasm is a major cause of morbidity and mortality in patients after aneurysmal subarachnoid hemorrhage. Early treatment of ruptured aneurysms is advocated; delayed intervention complicates the treatment strategy leading to significant vasospasm and poor prognosis. We report an endovascular protocol for occlusion of the unsecured aneurysm and angioplasty for vasospasm in a single session. Between January 2011 and May 2017, among 660 patients with aneurysmal subarachnoid hemorrhage, 24 patients with significant vasospasm and unsecured ruptured cerebral aneurysm were reviewed. Continuous nimodipine drip through a pressure line of the guiding catheter was set up. Aggressive angioplasty with a compliant balloon catheter either before or after embolization of the aneurysm in the major branches of vasospastic territory was performed. The goal was complete embolization of the aneurysm. Of 24 patients, 17 had ischemic symptoms at presentation, and the average delay from aneurysm rupture to presentation was 7.58 days. Angioplasty and nimodipine drip were performed on all patients. Severity of vasospasm was significantly reduced, and outcome improved in each patient. Two patients required a second angioplasty. In 20 patients, embolization of aneurysms was achieved without any aneurysmal sac or residual neck. Clinical outcome was good recovery (modified Rankin Scale score 0-2) in 23 patients (95.8%) and moderate disability in 1 patient (modified Rankin Scale score 3). Aggressive endovascular treatment of patients with unsecured ruptured cerebral aneurysm and associated vasospasm is safe and effective. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Curative embolization of pediatric intracranial arteriovenous malformations using Onyx: the role of new embolization techniques on patient outcomes.

    PubMed

    de Castro-Afonso, L H; Nakiri, G S; Oliveira, R S; Santos, M V; Santos, A C Dos; Machado, H R; Abud, D G

    2016-06-01

    Intracranial arteriovenous malformations (AVMs) are the most frequent cause of hemorrhagic strokes in the pediatric population. The study aim was to retrospectively assess the safety and efficacy of Onyx embolization with the intention to cure AVMs in a pediatric population. A retrospective analysis of all patients (<18 years) who underwent endovascular embolization using Onyx at our institution was conducted. The primary endpoint was the composite complete angiographic occlusion of AVM immediately after the last embolization session that had no procedure-related complication requiring emergency surgery. Secondary endpoints were angiographic occlusion rates, procedure-related complications, and clinical outcomes after treatment and at the 6-month follow-up Twenty-three patients (mean age, 11.7 years) underwent a total of 45 embolization sessions. The median Spetzler-Martin grade was 3 (range 1 to 4). The primary endpoint was achieved in 19 patients (82.6 %). Complete angiographic occlusion of the AVM was obtained in 21 patients (91.3 %) immediately after embolization and at the 6-month follow-up. Embolization-related complications were observed in three patients (13 %). None of the complications resulted in permanent functional disability or death. In two patients (8.7 %), the AVM could not be completely occluded by embolization alone and the patients were referred to radiosurgery and microsurgery, respectively. Onyx embolization of AVM in pediatric patients with the intention to cure resulted in high occlusion rates without increasing neurological disability or death. The development of new embolization techniques and devices seems to improve the safety of Onyx embolization.

  12. Air Force Cambridge Research Laboratories balloon operations

    NASA Technical Reports Server (NTRS)

    Danaher, T. J.

    1974-01-01

    The establishment and functions of the AFCRL balloon operations facility are discussed. The types of research work conducted by the facility are defined. The facilities which support the balloon programs are described. The free balloon and tethered balloon capabilities are analyzed.

  13. Morphological characterization of selected balloon films and its effects on balloon performances

    NASA Technical Reports Server (NTRS)

    Said, Magdi A.

    1994-01-01

    Morphological characterization of several polyethylene balloon films have been studied using various techniques. The objective is to determine, if any, differentiating structural or morphological features that can be related to the performance of these balloon film materials. The results of the study indicate that the films are composed of either linear low denstiy polyethylene (LLDPE) or low density polyethylene (LDPE). A selective examination of these data imply that films limited degree of branching and larger crystallites size (same % crystallinity) showed good mechanical properties that appear to correlate with their high level of success in balloon flights.

  14. Cross-linking reveals laminin coiled-coil architecture

    PubMed Central

    Armony, Gad; Jacob, Etai; Moran, Toot; Levin, Yishai; Mehlman, Tevie; Levy, Yaakov; Fass, Deborah

    2016-01-01

    Laminin, an ∼800-kDa heterotrimeric protein, is a major functional component of the extracellular matrix, contributing to tissue development and maintenance. The unique architecture of laminin is not currently amenable to determination at high resolution, as its flexible and narrow segments complicate both crystallization and single-particle reconstruction by electron microscopy. Therefore, we used cross-linking and MS, evaluated using computational methods, to address key questions regarding laminin quaternary structure. This approach was particularly well suited to the ∼750-Å coiled coil that mediates trimer assembly, and our results support revision of the subunit order typically presented in laminin schematics. Furthermore, information on the subunit register in the coiled coil and cross-links to downstream domains provide insights into the self-assembly required for interaction with other extracellular matrix and cell surface proteins. PMID:27815530

  15. The EUSO-Balloon pathfinder

    NASA Astrophysics Data System (ADS)

    Adams, J. H.; Ahmad, S.; Albert, J.-N.; Allard, D.; Anchordoqui, L.; Andreev, V.; Anzalone, A.; Arai, Y.; Asano, K.; Ave Pernas, M.; Baragatti, P.; Barrillon, P.; Batsch, T.; Bayer, J.; Bechini, R.; Belenguer, T.; Bellotti, R.; Belov, K.; Berlind, A. A.; Bertaina, M.; Biermann, P. L.; Biktemerova, S.; Blaksley, C.; Blanc, N.; Błȩcki, J.; Blin-Bondil, S.; Blümer, J.; Bobik, P.; Bogomilov, M.; Bonamente, M.; Briggs, M. S.; Briz, S.; Bruno, A.; Cafagna, F.; Campana, D.; Capdevielle, J.-N.; Caruso, R.; Casolino, M.; Cassardo, C.; Castellinic, G.; Catalano, C.; Catalano, G.; Cellino, A.; Chikawa, M.; Christl, M. J.; Cline, D.; Connaughton, V.; Conti, L.; Cordero, G.; Crawford, H. J.; Cremonini, R.; Csorna, S.; Dagoret-Campagne, S.; de Castro, A. J.; De Donato, C.; de la Taille, C.; De Santis, C.; del Peral, L.; Dell'Oro, A.; De Simone, N.; Di Martino, M.; Distratis, G.; Dulucq, F.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Engel, R.; Falk, S.; Fang, K.; Fenu, F.; Fernández-Gómez, I.; Ferrarese, S.; Finco, D.; Flamini, M.; Fornaro, C.; Franceschi, A.; Fujimoto, J.; Fukushima, M.; Galeotti, P.; Garipov, G.; Geary, J.; Gelmini, G.; Giraudo, G.; Gonchar, M.; González Alvarado, C.; Gorodetzky, P.; Guarino, F.; Guzmán, A.; Hachisu, Y.; Harlov, B.; Haungs, A.; Hernández Carretero, J.; Higashide, K.; Ikeda, D.; Ikeda, H.; Inoue, N.; Inoue, S.; Insolia, A.; Isgrò, F.; Itow, Y.; Joven, E.; Judd, E. G.; Jung, A.; Kajino, F.; Kajino, T.; Kaneko, I.; Karadzhov, Y.; Karczmarczyk, J.; Karus, M.; Katahira, K.; Kawai, K.; Kawasaki, Y.; Keilhauer, B.; Khrenov, B. A.; Kim, J.-S.; Kim, S.-W.; Kim, S.-W.; Kleifges, M.; Klimov, P. A.; Kolev, D.; Kreykenbohm, I.; Kudela, K.; Kurihara, Y.; Kusenko, A.; Kuznetsov, E.; Lacombe, M.; Lachaud, C.; Lee, J.; Licandro, J.; Lim, H.; López, F.; Maccarone, M. C.; Mannheim, K.; Maravilla, D.; Marcelli, L.; Marini, A.; Martinez, O.; Masciantonio, G.; Mase, K.; Matev, R.; Medina-Tanco, G.; Mernik, T.; Miyamoto, H.; Miyazaki, Y.; Mizumoto, Y.; Modestino, G.; Monaco, A.; Monnier-Ragaigne, D.; Morales de los Ríos, J. A.; Moretto, C.; Morozenko, V. S.; Mot, B.; Murakami, T.; Murakami, M. Nagano; Nagata, M.; Nagataki, S.; Nakamura, T.; Napolitano, T.; Naumov, D.; Nava, R.; Neronov, A.; Nomoto, K.; Nonaka, T.; Ogawa, T.; Ogio, S.; Ohmori, H.; Olinto, A. V.; Orleański, P.; Osteria, G.; Panasyuk, M. I.; Parizot, E.; Park, I. H.; Park, H. W.; Pastircak, B.; Patzak, T.; Paul, T.; Pennypacker, C.; Perez Cano, S.; Peter, T.; Picozza, P.; Pierog, T.; Piotrowski, L. W.; Piraino, S.; Plebaniak, Z.; Pollini, A.; Prat, P.; Prévôt, G.; Prieto, H.; Putis, M.; Reardon, P.; Reyes, M.; Ricci, M.; Rodríguez, I.; Rodríguez Frías, M. D.; Ronga, F.; Roth, M.; Rothkaehl, H.; Roudil, G.; Rusinov, I.; Rybczyński, M.; Sabau, M. D.; Sáez-Cano, G.; Sagawa, H.; Saito, A.; Sakaki, N.; Sakata, M.; Salazar, H.; Sánchez, S.; Santangelo, A.; Santiago Crúz, L.; Sanz Palomino, M.; Saprykin, O.; Sarazin, F.; Sato, H.; Sato, M.; Schanz, T.; Schieler, H.; Scotti, V.; Segreto, A.; Selmane, S.; Semikoz, D.; Serra, M.; Sharakin, S.; Shibata, T.; Shimizu, H. M.; Shinozaki, K.; Shirahama, T.; Siemieniec-Oziȩbło, G.; Silva López, H. H.; Sledd, J.; Słomińska, K.; Sobey, A.; Sugiyama, T.; Supanitsky, D.; Suzuki, M.; Szabelska, B.; Szabelski, J.; Tajima, F.; Tajima, N.; Tajima, T.; Takahashi, Y.; Takami, H.; Takeda, M.; Takizawa, Y.; Tenzer, C.; Tibolla, O.; Tkachev, L.; Tokuno, H.; Tomida, T.; Tone, N.; Toscano, S.; Trillaud, F.; Tsenov, R.; Tsunesada, Y.; Tsuno, K.; Tymieniecka, T.; Uchihori, Y.; Unger, M.; Vaduvescu, O.; Valdés-Galicia, J. F.; Vallania, P.; Valore, L.; Vankova, G.; Vigorito, C.; Villaseñor, L.; von Ballmoos, P.; Wada, S.; Watanabe, J.; Watanabe, S.; Watts, J.; Weber, M.; Weiler, T. J.; Wibig, T.; Wiencke, L.; Wille, M.; Wilms, J.; Włodarczyk, Z.; Yamamoto, T.; Yamamoto, Y.; Yang, J.; Yano, H.; Yashin, I. V.; Yonetoku, D.; Yoshida, K.; Yoshida, S.; Young, R.; Zotov, M. Yu.; Zuccaro Marchi, A.

    2015-11-01

    EUSO-Balloon is a pathfinder for JEM-EUSO, the Extreme Universe Space Observatory which is to be hosted on-board the International Space Station. As JEM-EUSO is designed to observe Ultra-High Energy Cosmic Rays (UHECR)-induced Extensive Air Showers (EAS) by detecting their ultraviolet light tracks "from above", EUSO-Balloon is a nadir-pointing UV telescope too. With its Fresnel Optics and Photo-Detector Module, the instrument monitors a 50 km2 ground surface area in a wavelength band of 290-430 nm, collecting series of images at a rate of 400,000 frames/sec. The objectives of the balloon demonstrator are threefold: a) perform a full end-to-end test of a JEM-EUSO prototype consisting of all the main subsystems of the space experiment, b) measure the effective terrestrial UV background, with a spatial and temporal resolution relevant for JEM-EUSO. c) detect tracks of ultraviolet light from near space for the first time. The latter is a milestone in the development of UHECR science, paving the way for any future space-based UHECR observatory. On August 25, 2014, EUSO-Balloon was launched from Timmins Stratospheric Balloon Base (Ontario, Canada) by the balloon division of the French Space Agency CNES. From a float altitude of 38 km, the instrument operated during the entire astronomical night, observing UV-light from a variety of ground-covers and from hundreds of simulated EASs, produced by flashers and a laser during a two-hour helicopter under-flight.

  16. Crisis management during anaesthesia: embolism

    PubMed Central

    Williamson, J; Helps, S; Westhorpe, R; Mackay, P

    2005-01-01

    Background: Embolism with gas, thrombus, fat, amniotic fluid, or particulate matter may occur suddenly and unexpectedly during anaesthesia, posing a diagnostic and management problem for the anaesthetist. Objectives: To examine the role of a previously described core algorithm "COVER ABCD–A SWIFT CHECK" supplemented by a specific sub-algorithm for embolism, in the management of embolism occurring in association with anaesthesia. Methods: The potential performance of this structured approach for each of the relevant incidents among the first 4000 reported to the Australian Incident Monitoring Study (AIMS) was compared with the actual management as reported by the anaesthetists involved. Results: Among the first 4000 incidents reported to AIMS, 38 reports of embolism were found. A sudden fall in end-tidal carbon dioxide and oxygen saturation were the cardinal signs of embolism, each occurring in about two thirds of cases, with hypotension and electrocardiographic changes each occurring in about one third of cases. Conclusion: The potential value of an explicit structured approach to the diagnosis and management of embolism was assessed in the light of AIMS reports. It was considered that, correctly applied, it potentially would have led to earlier recognition of the problem and/or better management in over 40% of cases. PMID:15933290

  17. Coiled-coil intermediate filament stutter instability and molecular unfolding.

    PubMed

    Arslan, Melis; Qin, Zhao; Buehler, Markus J

    2011-05-01

    Intermediate filaments (IFs) are the key components of cytoskeleton in eukaryotic cells and are critical for cell mechanics. The building block of IFs is a coiled-coil alpha-helical dimer, consisting of several domains that include linkers and other structural discontinuities. One of the discontinuities in the dimer's coiled-coil region is the so-called 'stutter' region. The stutter is a region where a variation of the amino acid sequence pattern from other parts of the alpha-helical domains of the protein is found. It was suggested in earlier works that due to this sequence variation, the perfect coiled-coil arrangement ceases to exist. Here, we show using explicit water molecular dynamics and well-tempered metadynamics that for the coil2 domain of vimentin IFs the stutter is more stable in a non-alpha-helical, unfolded state. This causes a local structural disturbance in the alpha helix, which has a global effect on the nanomechanics of the structure. Our analysis suggests that the stutter features an enhanced tendency to unfolding even under the absence of external forces, implying a much greater structural instability than previously assumed. As a result it features a smaller local bending stiffness than other segments and presents a seed for the initiation of molecular bending and unfolding at large deformation.

  18. RF HEATING OF MRI-ASSISTED CATHETER STEERING COILS FOR INTERVENTIONAL MRI

    PubMed Central

    Settecase, Fabio; Hetts, Steven W.; Martin, Alastair J.; Roberts, Timothy P. L.; Bernhardt, Anthony F.; Evans, Lee; Malba, Vincent; Saeed, Maythem; Arenson, Ronald L.; Kucharzyk, Walter; Wilson, Mark W.

    2010-01-01

    RATIONALE AND OBJECTIVES To assess magnetic resonance imaging (MRI) radiofrequency (RF) related heating of conductive wire coils used in magnetically steerable endovascular catheters. MATERIALS AND METHODS A 3-axis microcoil was fabricated onto a 1.8 Fr catheter tip. In vitro testing was performed in a 1.5 T MRI system using an agarose gel filled vessel phantom, a transmit/receive body RF coil and a steady state free precession (SSFP) pulse sequence, and a fluoroptic thermometry system. Temperature was measured without simulated blood flow at varying distances from magnet isocenter and varying flip angles. Additional experiments were performed with laser-lithographed single-axis microcoil-tipped microcatheters in air and in a saline bath with varied grounding of the microcoil wires. Preliminary in vivo evaluation of RF heating was performed in pigs at 1.5 T with coil-tipped catheters in various positions in the common carotid arteries with SSFP pulse sequence on and off, and under physiologic flow and zero flow conditions. RESULTS In tissue-mimicking agarose gel, RF heating resulted in a maximal temperature increase of 0.35°C after 15 minutes of imaging, 15 cm from magnet isocenter. For a single axis microcoil, maximal temperature increases were 0.73-1.91°C in air and 0.45-0.55°C in saline. In vivo, delayed contrast enhanced MRI revealed no evidence of vascular injury and histopathological sections from the common carotid arteries confirmed the lack of vascular damage. CONCLUSIONS Microcatheter tip microcoils for endovascular catheter steering in MRI experience minimal RF heating under the conditions tested. These data provide the basis for further in vivo testing of this promising technology for endovascular interventional MRI. PMID:21075019

  19. RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRI.

    PubMed

    Settecase, Fabio; Hetts, Steven W; Martin, Alastair J; Roberts, Timothy P L; Bernhardt, Anthony F; Evans, Lee; Malba, Vincent; Saeed, Maythem; Arenson, Ronald L; Kucharzyk, Walter; Wilson, Mark W

    2011-03-01

    The aim of this study was too assess magnetic resonance imaging (MRI) radiofrequency (RF)-related heating of conductive wire coils used in magnetically steerable endovascular catheters. A three-axis microcoil was fabricated onto a 1.8Fr catheter tip. In vitro testing was performed on a 1.5-T MRI system using an agarose gel-filled vessel phantom, a transmit-receive body RF coil, a steady-state free precession pulse sequence, and a fluoroptic thermometry system. Temperature was measured without simulated blood flow at varying distances from the magnet isocenter and at varying flip angles. Additional experiments were performed with laser-lithographed single-axis microcoil-tipped microcatheters in air and in a saline bath with varied grounding of the microcoil wires. Preliminary in vivo evaluation of RF heating was performed in pigs at 1.5 T with coil-tipped catheters in various positions in the common carotid arteries with steady-state free precession pulse sequence on and off and under physiologic-flow and zero-flow conditions. In tissue-mimicking agarose gel, RF heating resulted in a maximal temperature increase of 0.35°C after 15 minutes of imaging, 15 cm from the magnet isocenter. For a single-axis microcoil, maximal temperature increases were 0.73°C to 1.91°C in air and 0.45°C to 0.55°C in saline. In vivo, delayed contrast-enhanced MRI revealed no evidence of vascular injury, and histopathologic sections from the common carotid arteries confirmed the lack of vascular damage. Microcatheter tip microcoils for endovascular catheter steering in MRI experience minimal RF heating under the conditions tested. These data provide the basis for further in vivo testing of this promising technology for endovascular interventional MRI. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  20. Is a high initial World Federation of Neurosurgery (WFNS) grade really associated with a poor clinical outcome in elderly patients with ruptured intracranial aneurysms treated with coiling?

    PubMed

    Iosif, Christina; Di Maria, Federico; Sourour, Nader; Degos, Vincent; Bonneville, Fabrice; Biondi, Alessandra; Jean, Betty; Colonne, Chantal; Nouet, Aurelien; Chiras, Jacques; Clarençon, Frédéric

    2014-05-01

    Coiling of ruptured intracranial aneurysms in elderly patients remains debatable in terms of technical feasibility and clinical outcome. In this observational cohort study we aimed to assess the technical feasibility, complication profile and clinical outcomes of elderly patients with subarachnoid hemorrhage (SAH) treated with endovascular therapy. The study included 59 consecutive patients (47 women) aged ≥70 years (mean age 76 years, range 71-84) admitted to our institution with SAH from January 2002 to July 2011. The patients were treated for 66 aneurysms (regular coiling: n=62 (94%), balloon-assisted technique: n=2 (3%), stent and coil technique: n=2 (3%)). World Federation of Neurosurgery (WFNS) grade at admission was 1 in 13 patients, 2 in 23 patients, 3 in 8 patients, 4 in 11 patients and 5 in 4 patients. We analysed data by univariate and multivariate statistical analyses with an emphasis on the initial clinical situation, complications and clinical outcome. The technical success rate was 98% with a procedure-related deficit rate of 10% and procedure-related death rate of 5%. The Glasgow Outcome Scale score at 6 months was 1 in 15 patients (25.4%), 2 in 8 patients (13.6%), 3 in 14 patients (23.7%), 4 in 11 patients (18.6%) and 5 in 11 patients (18.6%). Patients admitted with a high initial WFNS grade did not differ statistically in terms of clinical outcome. The final clinical outcome was not significantly correlated with age, initial Fisher score or procedure-related complications. Endovascular treatment of elderly patients with ruptured cerebral aneurysms is feasible, safe and beneficial regardless of the presenting WFNS score.