Triharpini, Ni Nyoman; Gede Jayanegara, I Wayan; Handayani, Ariesanti Tri; Widiana, I Gde Raka
2015-01-01
Corneal erosion is common in eye emergency cases. Extensive corneal erosions result in severe pain and prolonged healing time. This study aimed to compare bandage contact lenses with pressure patching in terms of reducing the size of the erosion area, pain scale in patients with corneal erosion and its complications. A randomized open-label clinical trial was conducted. Subjects with mechanical corneal erosion were selected to use either bandage contact lenses or pressure patching. All subjects received antibiotic eye drops and 0.5% tropicamide eye drops. Evaluations were done 24 and 72 hours after treatment. The size of the corneal erosion area, pain scale, and complications were assessed. A total of 32 eyes (16 eyes in each group) were studied. The change in the size of the corneal erosion area was greater in the bandage contact lens group than in the pressure patching group, although there was no significant difference. In the bandage contact lens group, 56.25% of the eyes were healed at 24 hours and 43.75% were healed at 72 hours. In the pressure patching group, 62.50% were healed at 24 hours and 12.50% were healed at 72 hours. The change in pain scale was significantly greater in the bandage contact lens group than in the pressure patching group. No complications were found in both groups. Bandage contact lenses are an effective alternative to treating mechanical corneal erosion because of their effect in reducing pain without causing any complications.
The effects of two different types of bandage contact lenses on the healthy canine eye.
Braus, Barbara Katharina; Riedler, Daniela; Tichy, Alexander; Spergser, Joachim; Schwendenwein, Ilse
2018-02-06
To compare two types of bandage contact lenses on the healthy canine eye. Six healthy Beagles. Two different types of bandage contact lenses (single sized human silicone contact lens 'PureVision 2' (Bausch & Lomb Incorporated, Rochester, NY, USA) and specially designed veterinary hydrogel contact lens 'AcriVet Pat D' (Bausch & Lomb Incorporated) were placed in 12 eyes of healthy Beagle dogs. Retention times and the effects of the lenses regarding irritation of the eye, changes in tear production, impact of contact lenses on tonometric readings, and cytologic and microbiological alterations of the canine eye were investigated. Mean retention times for veterinary hydrogel lenses with special dimensions were significantly shorter (2 days) than for one size human silicon lenses (8.8 days). Irritation scores were overall low for both types of lenses apart from one human lens causing severe irritation and keratoconjunctivitis as a sequel to folding and displacement. Tear production remained stable in human contact lenses. Intraocular pressure readings with a contact lens in place were only slightly altered; the most accurate readings were obtained through a human lens with an applanation tonometer. Cytology revealed a slight, nonsignificant increase in neutrophilic granulocytes with both types of lenses; the microflora did not change significantly. Human silicone lenses have significantly longer retention times and are less expensive than veterinary hydrogel lenses. In regard to irritation, bacterial growth and inflammation, both types of lenses can be recommended for use in canine eyes. © 2018 American College of Veterinary Ophthalmologists.
Pereira, Carlos Eduardo Gonçalves; Hida, Richard Yudi; Silva, Cely Barreto; de Andrade, Marizilda Rita; Fioravanti-Lui, Giovana Arlene; Lui-Netto, Adamo
2015-05-01
To describe the microbiological findings from bandage contact lenses in patients who work in a hospital environment submitted to photorefractive keratectomy (PRK). This prospective comparative case series enrolled 43 eyes of 22 volunteers (28.05 ± 3.50 years). Fourteen individuals (n = 27) were health care professionals who work in health care facilities or community physician's offices. Eight individuals (n = 16) were patients who do not work in hospital environment. Photorefractive keratectomy was performed using standard technique, and a silicone hydrogel bandage contact lens was placed on the cornea and evaluated for adequate fit. Seven days after surgery, the bandage lenses were removed and imprinted in the following culture media: blood agar, chocolate agar, anaerobic-selective agar, and Sabouraud agar. When microbial growth was detected, the microorganism was identified, colony-forming units were quantified, and morphology and Gram-staining properties were analyzed. All isolates were tested for susceptibility to various antibiotics. Significance was assessed by Fisher exact test. Microbial growth was detected in 16.27% of all contact lenses samples. No fungi or anaerobes were found. Microbial growth was only observed in bandage lenses removed from patients who work in hospital environments. Most microorganisms found were sensitive to all antibiotics tested. These results suggest that working in hospital environments increase contamination of the contact lenses after PRK.
Brothers, Kimberly M; Nau, Amy C; Romanowski, Eric G; Shanks, Robert M Q
2014-10-01
This study was designed to measure the impact of bacterial biofilms on diffusion of an ocular therapeutic through silicone hydrogel bandage lenses in vitro. An assay was designed to study the passage of a commonly used steroid, dexamethasone, through silicone hydrogel soft contact lenses. Diffused dexamethasone was measured using a spectrophotometer over a period of 18 hours and quantified using a standard curve. This assay was performed with control and Staphylococcus epidermidis biofilm-coated contact lenses comprised of lotrafilcon A and methafilcon. Biofilms were formed in brain heart infusion broth supplemented with D-glucose. The presented data validate a simple in vitro model that can be used to measure the penetration of a topical therapeutic through silicone hydrogel soft contact lenses. Using this model, we measured a reduction in dexamethasone diffusion up to 88% through S. epidermidis biofilm-coated silicone hydrogel lenses compared with control lenses. The results of this in vitro study demonstrate that bacterial biofilms impede dexamethasone diffusion through silicone hydrogel contact lenses and warrant future studies regarding the clinical benefit of using ocular therapeutics in the setting of bandage contact lens use for corneal epithelial defects.
Brothers, Kimberly M.; Nau, Amy C.; Romanowski, Eric G.; Shanks, Robert M. Q.
2014-01-01
Purpose This study was designed to measure the impact of bacterial biofilms on diffusion of an ocular therapeutic through silicone hydrogel bandage lenses in vitro. Methods An assay was designed to study the passage of a commonly used steroid dexamethasone through the silicone hydrogel soft contact lenses. Diffused dexamethasone was measured using a spectrophotometer over a period of 18 hours and quantified using a standard curve. This assay was performed with control and Staphylococcus epidermidis biofilm-coated contact lenses composed of lotrafilcon A and methafilcon. Biofilms were formed in brain heart infusion broth supplemented with D-glucose. Results The presented data validate a simple in vitro model that can be used to measure penetration of a topical therapeutic through silicone hydrogel soft contact lenses. Using this model we measured a reduction of dexamethasone diffusion by up to 88% through S. epidermidis biofilm-coated silicon hydrogel lenses compared to control lenses. Conclusions The results of this in vitro study demonstrate that bacterial biofilms impede dexamethasone diffusion through silicon hydrogel contact lenses, and warrant future studies regarding the clinical benefit of using ocular therapeutics in the setting of bandage contact lens use for corneal epithelial defects. PMID:25090165
Yuksel, Erdem; Yalcin, Nuriye Gokçen; Kilic, Gaye; Cubuk, Mehmet Ozgur; Ozmen, Mehmet Cuneyt; Altay, Aylin; Çağlar, Kayhan; Bilgihan, Kamil
2016-01-01
To investigate the agents of bacterial contamination of contact lenses after corneal collagen cross-linking (CCL), and to present the possible changes of ocular flora after riboflavin/ultraviolet A. Seventy-two contact lenses of patients who underwent CCL and 41 contact lenses of patients who underwent photorefractive keratectomy (PRK) as control group were enrolled to the study. After 48 h of incubation, broth culture media was transferred to plates. Samples were accepted as positive if one or more colony-forming units were shown. There were positive cultures in 12 (16.7%) contact lenses in the CCL group and 5 (12.2%) had positive cultures in PRK group. Coagulase-negative staphlycocci (CNS) were the most frequent microorganism. Alpha hemolytic streptococci and Diphteroid spp. were the other isolated microorganisms. Bacterial colonization can occur during and early after the CCL procedure in epithelial healing. To prevent corneal infections after the treatment, prophylactic antibiotics should be prescribed.
2017-10-22
PRK Inflammation in a Rabbit Model Timothy A. Soekenl, Michael Merkley!, Wesley Brundridgel, Gary Legaultl, Matthew Caldwelll, Joseph Ciolino2...7 .0 Dexamethasone Impregnated Contact Lenses in the Treatment of Post- PRK Inflammation · in a Rabbit Model Timothy A. Soeken 1, Michael Merkley1
Microbiologic study of soft contact lenses after laser subepithelial keratectomy for myopia.
Hondur, Ahmet; Bilgihan, Kamil; Cirak, Meltem Yalinay; Dogan, Ozgur; Erdinc, Alper; Hasanreisoglu, Berati
2008-01-01
To evaluate the extent and agents of bacterial contamination of bandage disposable soft contact lenses after laser subepithelial keratectomy (LASEK) and to correlate the findings with clinical data. Disposable soft contact lenses were collected from 52 eyes of 26 consecutive patients treated with LASEK for myopia. The patients were treated with a fixed combination of tobramycin and diclofenac until epithelial closure. The lenses were removed on the fourth or fifth postoperative day with sterile forceps and immediately placed in sterile tubes containing culture media brain-heart infusion broth. The lenses were evaluated for microbial colonization. Of the 52 contact lenses analyzed, six (11.5%) had positive cultures. However, no clinical finding of infection was noted. Isolated microorganisms were coagulase-negative staphylococci (two lenses), Stenotrophomonas maltophilia (two lenses), Acinetobacter species (one lens), and Aeromonas hydrophila (one lens). Except for one case, the microorganisms were sensitive to the administered antibiotic. The risk of infectious keratitis after LASEK seems to be low. Except for staphylococci, the isolated microorganisms have not been previously reported to colonize the ocular surface or cause keratitis after refractive surgery. These findings may suggest a changing trend of potentially infectious agents after surface ablation.
Corneal Epitheliopathy After Trauma by Fake Snow Powder in a 7-year-old Child
Al-Amry, Mohammad A.; Al-Ghadeer, Huda A.
2016-01-01
Fake snow is a polymer of sodium polyacrylates used in games and celebrations. Despite the product leaflet that indicates safety, contact with the ocular surface can cause injury. We report a case of a child with corneal epitheliopathy due to a chemical burn injury after ocular surface contact with fake snow. The case was managed with epithelial debridement and a bandage contact lenses and topical antibiotics with complete resolution. PMID:27555717
Alarcon, E I; Vulesevic, B; Argawal, A; Ross, A; Bejjani, P; Podrebarac, J; Ravichandran, R; Phopase, J; Suuronen, E J; Griffith, M
2016-03-28
Despite the broad anti-microbial and anti-inflammatory properties of silver nanoparticles (AgNPs), their use in bioengineered corneal replacements or bandage contact lenses has been hindered due to their intense yellow coloration. In this communication, we report the development of a new strategy to pre-stabilize and incorporate AgNPs with different colours into collagen matrices for fabrication of corneal implants and lenses, and assessed their in vitro and in vivo activity.
Liu, Xiaowei; Wang, Peng; Kao, Andrew A; Jiang, Yang; Li, Ying; Long, Qin
2012-07-01
To compare the locations and types of bacterial contamination of bandage disposable soft contact lenses after laser subepithelial keratectomy (LASEK) and photorefractive keratectomy (PRK). Bandage disposable soft contact lenses were collected with sterile forceps from 30 eyes of 15 consecutive patients treated with LASEK (LASEK group) and 30 eyes of 15 consecutive patients who underwent PRK (PRK group) to correct myopia. Immediately after collection, each lens was cut in two parts with sterile scissors and placed onto chocolate agar with one piece outer face down and the inner face down for the other piece. The lenses were analyzed for bacterial colonization and evaluated for the amount of growth on the inner face and outer face, respectively. The antibiotic susceptibility tests were performed for the isolates using disk diffusion. Five positive cultures (16.7%) were found in LASEK group: 4 appeared in the inner face of the lens and1 appeared in the outer face. In PRK group, 2 of the 30 contact lenses (6.67%) had positive cultures; both of them appeared in the outer face of the lens. The difference of positive culture rate in the two groups was not statistically significant (χ=1.46, P=0.228). When comparing the positive colonization rate in location, the positive culture rate in the inner face of LASEK group was statistically significantly higher than that of PRK group (13.3% vs. 0%, χ=4.29, P=0.038); however, no clinical finding of infection was noted. In both groups, methicillin-sensitive coagulase-negative staphylococci (MSSCoN) were the most common isolate. Besides MSSCoN, the growth of methicillin-resistant coagulase-negative staphylococci, Corynebacterium, and Micrococcus were also present in this study. All the microorganisms were sensitive to tobramycin, which was used in conjunction with dexamethasone to treat the cases. Previous literature reports that the risk of infectious keratitis after LASEK or PRK is relatively low. However, within this study, the rate of positive cultures was relatively higher in LASEK group (16.7%) compared with that of PRK group (6.67%), especially in the inner face of the lens. The reason may be related to the procedure of keeping the epithelial flap in place, which could develop a local environment suitable for bacterial colonization and potential infection. Coagulase-negative staphylococci, a major element of the natural conjunctival flora, remain a major potentially infectious agent after LASEK and PRK.
Tseng, Santos Shan-Yu; Yang, Winston Wen-Ching; Hsiao, John Ching-Jen
2008-12-01
We report a case demonstrating the importance of trial fitting before the dispensing of prescription contact lenses. The patient was an 18-year-old computer-using experienced hydrogel lens wearer who ran out of contact lens supply. The patient purchased a brand new box of daily disposable lenses from a retail store having known his back vertex power. No trial fitting of the lenses was performed at the point of sale. After a day of wear of the lenses with significant computer use, the patient removed them and went to bed, but the next morning, presented on an emergency basis with severe pain and blurry vision in both eyes. Slit lamp examination showed significant bilateral corneal erosions that were treated with prophylactic antibiotics, steroids, and lubricants. A bandage contact lens was further given to his right eye. The characteristics of the daily disposable lenses and his computer overuse were viewed as contributing factors to the complication. The dispensing and wear of prescription contact lenses without a proper selection and fit led to bilateral corneal erosions in this patient. Though our case occurred in Taiwan, a jurisdiction where prescription contact lens sale is not regulated, the authors note that such a scenario could occur in jurisdictions where contact lens sale is regulated if, after confirmation of back vertex power, no effort is made to ensure that a purchased lens is safe or appropriate for a patient, such as when lenses are purchased through internet suppliers or in certain commercial retail settings.
Diffusion of Antimicrobials Across Silicone Hydrogel Contact Lenses
Zambelli, Alison M.; Brothers, Kimberly M.; Hunt, Kristin M.; Romanowski, Eric G.; Nau, Amy C.; Dhaliwal, Deepinder K.; Shanks, Robert M. Q.
2014-01-01
Objectives To measure the diffusion of topical preparations of moxifloxacin, amphotericin B (AmB), and polyhexamethylene biguanide (PHMB) through silicone hydrogel (SH) contact lenses in vitro. Methods Using an in vitro model, the diffusion of three antimicrobials through SH contact lenses was measured. Diffused compounds were measured using a spectrophotometer at set time points over a period of four hours. The amount of each diffused antimicrobial was determined by comparing the experimental value to a standard curve. A biological assay was performed to validate the contact lens diffusion assay by testing antimicrobial activity of diffused material against lawns of susceptible bacteria (Staphylococcus epidermidis) and yeast (Saccharomyces cerevisiae). Experiments were repeated at least two times with a total of at least 4 independent replicates. Results Our data show detectable moxifloxacin and PHMB diffusion through SH contact lenses at 30 minutes, while amphotericin B diffusion remained below the limit of detection within the 4 hour experimental period. In the biological assay, diffused moxifloxacin demonstrated microbial killing starting at 20 minutes on bacterial lawns, whereas PHMB and amphotericin B failed to demonstrate killing on microbial lawns over the course of the 60 minute experiment. Conclusions In vitro diffusion assays demonstrate limited penetration of certain anti-infective agents through silicone hydrogel contact lenses. Further studies regarding the clinical benefit of using these agents along with bandage contact lens use for corneal pathology are warranted. PMID:25806673
Mukherjee, Achyut; Ioannides, Antonis; Aslanides, Ioannis
2014-01-01
Purpose To evaluate and compare Comfilcon A and Senofilcon A silicone hydrogel contact lenses used as a therapeutic bandage following transepithelial excimer laser photorefractive keratectomy (PRK). Methods Patients undergoing transepithelial PRK for myopia were prospectively recruited. Included patients had a Comfilcon A silicone hydrogel lens inserted in one eye, with a Senofilcon A lens in the contralateral eye. Postoperative assessment of subjective pain, epithelial healing and visual recovery was at day 1, 3 and 7. Contact lens factors including centration, movement and deposits were assessed. Results 48 eyes of 24 patients were included in the study. Mean age was 31 years (SD 11) and mean refractive error −4.5 D (SD 1.8). Mean pain score at day 1 was significantly higher in the Comfilcon group at 4.6 (SD 2.7) vs. 1.5 (SD2.5) in the Senofilcon group (P < 0.005). Mean time to healing was 3.17 days (SD 0.37) in the Comfilcon group, and 3.21 days (SD 0.4) in the Senofilcon group, with no difference in defect size. There was a pronounced central raphe in 1 eye in the Comfilcon group vs. 5 eyes in the Senofilcon group (P = 0.19). Significantly more eyes demonstrated no lens movement in the Senofilcon group (18 vs. 4, P = 0.0001). Conclusion The variation in material characteristics and lens geometry of different silicone hydrogel lenses affects their clinical characteristics in therapeutic roles. Other factors than oxygen permeability may affect pain and epithelial healing, with superior pain relief from the less permeable Senofilcon lens in this study. PMID:25649638
Mukherjee, Achyut; Ioannides, Antonis; Aslanides, Ioannis
2015-01-01
To evaluate and compare Comfilcon A and Senofilcon A silicone hydrogel contact lenses used as a therapeutic bandage following transepithelial excimer laser photorefractive keratectomy (PRK). Patients undergoing transepithelial PRK for myopia were prospectively recruited. Included patients had a Comfilcon A silicone hydrogel lens inserted in one eye, with a Senofilcon A lens in the contralateral eye. Postoperative assessment of subjective pain, epithelial healing and visual recovery was at day 1, 3 and 7. Contact lens factors including centration, movement and deposits were assessed. 48 eyes of 24 patients were included in the study. Mean age was 31 years (SD 11) and mean refractive error -4.5 D (SD 1.8). Mean pain score at day 1 was significantly higher in the Comfilcon group at 4.6 (SD 2.7) vs. 1.5 (SD2.5) in the Senofilcon group (P<0.005). Mean time to healing was 3.17 days (SD 0.37) in the Comfilcon group, and 3.21 days (SD 0.4) in the Senofilcon group, with no difference in defect size. There was a pronounced central raphe in 1 eye in the Comfilcon group vs. 5 eyes in the Senofilcon group (P=0.19). Significantly more eyes demonstrated no lens movement in the Senofilcon group (18 vs. 4, P=0.0001). The variation in material characteristics and lens geometry of different silicone hydrogel lenses affects their clinical characteristics in therapeutic roles. Other factors than oxygen permeability may affect pain and epithelial healing, with superior pain relief from the less permeable Senofilcon lens in this study. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Dixon, Phillip; Ghosh, Tanushri; Mondal, Kalyani; Konar, Aditya; Chauhan, Anuj; Hazra, Sarbani
2018-06-01
Chemical injury by alkali burn is a major cause of corneal blindness in the clinical setting. Current management advocates multiple therapies aimed to prevent inflammation, initiate quick re-epithelialization, arrest the fibrosis, and avoid dry eye and pain by using bandage contact lenses. We hypothesized sustained delivery of the anti-inflammatory, antifibrotic drug pirfenidone through vitamin E-loaded contact lenses as a logical single approach to counter the pathology involved. Vitamin E particles were created in situ in commercial silicon hydrogel contact lenses by soaking the lenses in a vitamin E-ethanol solution. The vitamin E-laden lenses were then placed into pirfenidone-saline solution to load the drug into the lens. The contact lenses were evaluated by both in vitro and in vivo means. For in vitro, lenses were placed into 3 mL of saline solution. The concentration of pirfenidone released was measured by UV-vis spectrophotometry. The contact lenses were implanted in rabbit eyes following the alkali burn; the drug availability in the aqueous humor was evaluated by HPLC at various time points 10 min, 30 min, 2 h, and 3 h; and gene expression of inflammatory cytokines IL-1β, TNF-α, and TGF-β1 was evaluated in the cornea at the end of the study period. In another group of rabbits inflicted with alkali injury, the corneas were graded after 7 days of contact lens implantation with and without pirfenidone. A mathematical model was developed for delivery of the drug to the cornea and aqueous humor after a contact lens is inserted in the eye. The model was validated with experimental data and used to determine the bioavailability both for contact lenses and eye drops. In vitro release of unmodified commercial contact lenses saw a release time of approximately 20 min, with a partition coefficient of 2.68 ± 0.06. The release of pirfenidone from 20% vitamin E-loaded lenses saw a release time of approximately 80 min, with a partition coefficient of 4.20 ± 0.04. In vivo, the drug was available in the aqueous humor for up to 3 h. Gene expression of inflammatory cytokine IL-β1 and profibrotic growth factor TGF-β1 was significantly suppressed in corneas treated with pirfenidone contact lenses. A week after the alkali burn, the eyes with pirfenidone contact lenses showed significant improvement in corneal haze in comparison to the control eyes. About 50% of the drug loaded in the lens reached the aqueous humor compared to 1.3% with eye drops. Vitamin E-loaded contact lenses serve as a suitable platform for delivery of pirfenidone following alkali burn in rabbit eyes; positive pre-clinical outcome identifies it as promising therapy for addressing corneal inflammation and fibrosis. The bioavailability is about 40-fold higher for contact lenses compared to that for eye drops.
Bandage soft contact lenses for ocular graft-versus-host disease
Inamoto, Yoshihiro; Sun, Yi-Chen; Flowers, Mary E. D.; Carpenter, Paul A.; Martin, Paul J.; Li, Peng; Wang, Ruikang; Chai, Xiaoyu; Storer, Barry E.; Shen, Tueng T.; Lee, Stephanie J.
2015-01-01
To examine safety and efficacy of bandage soft contact lenses (BSCLs) for ocular chronic graft-versus host disease (GVHD), we conducted a phase II clinical trial. Extended-wear BSCLs were applied under daily topical antibiotics prophylaxis. Patients completed standardized symptom questionnaires at enrollment and at 2 weeks, 4 weeks and 3 months afterwards. Ophthalmologic assessment was performed at enrollment, at 2 weeks and afterwards as medically needed. Assessments at follow-up were compared with baseline by paired t-test. Nineteen patients with ocular GVHD who remained symptomatic despite conventional treatments were studied. The mean Lee eye subscale score was 75.4 at enrollment, and improved significantly to 63.2 at 2 weeks (p=0.01), to 61.8 at 4 weeks (p=0.005) and to 56.3 at 3 months (p=0.02). The ocular surface disease index score and 11-point eye symptom ratings also improved significantly. According to the Lee eye subscale, clinically meaningful improvement was observed in 9 patients (47%) at 2 weeks, in 11 (58%) at 4 weeks and in 9 (47%) at 3 months. Visual acuity improved significantly at 2 weeks compared with enrollment values. Based on slit lamp exam at 2 weeks, punctate epithelial erosions improved in 58% of the patients, showed stability in 16% and worsened in 5%. No corneal ulceration or ocular infection occurred. BSCLs are a widely available, safe and effective treatment option that improves manifestations of ocular graft-versus host disease in approximately 50% of patients. This study was registered at www.clinicaltrials.gov as NCT01616056. PMID:26189353
Widman, Travis J; Oostman, Holly; Storrs, Frances J
2008-01-01
Medical adhesive bandages are extensively used in both inpatient and outpatient medicine. However, few reports describing proven allergic contact dermatitis (ACD) from medical adhesive bandages exist in the literature. These reports do not adequately correspond to the frequency that patients report having an "allergy" to medical adhesive bandages. To determine if there is a chemical present in medical adhesive bandages that causes ACD in people who identify themselves as having an "allergy" to medical adhesive bandages. Twenty-six patients were enrolled and underwent patch testing with our standard trays (104 chemicals) and a customized adhesive tray (54 chemicals and 10 tapes and bandages in their whole form). We were able to identify an allergen in four patients that was related to their presumed adhesive allergy (Mastisol, neomycin/bacitracin [two different patients], and cortisone-10 cream, respectively). However, there were no positive allergic reactions to the tapes or bandages or any relevant allergic reactions to our customized adhesive tray. Eight (73%) of the 11 patients who had the bandage or tape left on for 7 days had an irritant reaction. We feel that the perceived reactions are not secondary to ACD but instead are due to an irritant contact dermatitis.
NASA Astrophysics Data System (ADS)
Alarcon, E. I.; Vulesevic, B.; Argawal, A.; Ross, A.; Bejjani, P.; Podrebarac, J.; Ravichandran, R.; Phopase, J.; Suuronen, E. J.; Griffith, M.
2016-03-01
Despite the broad anti-microbial and anti-inflammatory properties of silver nanoparticles (AgNPs), their use in bioengineered corneal replacements or bandage contact lenses has been hindered due to their intense yellow coloration. In this communication, we report the development of a new strategy to pre-stabilize and incorporate AgNPs with different colours into collagen matrices for fabrication of corneal implants and lenses, and assessed their in vitro and in vivo activity.Despite the broad anti-microbial and anti-inflammatory properties of silver nanoparticles (AgNPs), their use in bioengineered corneal replacements or bandage contact lenses has been hindered due to their intense yellow coloration. In this communication, we report the development of a new strategy to pre-stabilize and incorporate AgNPs with different colours into collagen matrices for fabrication of corneal implants and lenses, and assessed their in vitro and in vivo activity. Electronic supplementary information (ESI) available: Collagen hydrogel, moulded as a cornea, prepared containing collagen protected AgNPs and representative images for collagen hydrogels, moulded as corneas, containing Blue AgNPs either unprotected or protected with LL37-SH; representative TEM images for Green-1 AgNPs prepared in this work; changes on surface plasmon band after synthesis for Green-2 AgNPs without LL37-SH; representative picture of the powder obtained for Green-1 AgNPs capped with LL37-SH after 72 h lyophilization, see main text; representative TEM images for Blue and Green-1 AgNPs prepared in this work; absorption spectra for the supernatants for collagen hydrogels containing Blue AgNPs; absorbance at 600 nm of PAO1 cultures prepared in 25% LB media incubated for 14 h at 37 °C in the presence of different concentrations of AgNPs, Green-1 or Blue, or silver nitrate; HECC cell density (cells per cm2) measured on gels with and without silver nitrate after 1 day of cell incubation; total silver concentration in tissue surrounding the implant area, see experimental, measured at 24 and 72 h post surgery; concentration of mouse IL-6 in homogenized skin tissue extracted from gel implant region after 24 h and 72 h. See DOI: 10.1039/c6nr01339b
Clinical evaluation of succinylated collagen bandage lenses for ophthalmic applications.
Hadassah, J; Prakash, D; Sehgal, P K; Agarwal, A; Bhuvaneshwari, N
2008-01-01
To study whether succinylated collagen bandage lenses (SCBL) prepared from modified bovine collagen (succinylated collagen) can replace other bandage lenses presently employed to treat various corneal conditions like filamentary keratitis, dry eyes, recurrent corneal erosions, foreign body removal and epithelial trauma. This observational case study included 32 patients (22 female and 10 male): 8 patients for filamentary keratitis (25%), 10 patients for dry eyes (31%), 4 patients for recurrent corneal erosions (13%), 7 patients for foreign body removal (22%) and 3 patients for epithelial trauma (9%). Their eyes were evaluated for biocompatibility, in vivo transparency, patient comfort, corneal fit, best corrected visual acuity (BCVA), tear fluid level and dissolution rate of SCBL. This was carried out over a 24-hour period of time. SCBL exhibited good transparency and remained transparent throughout the period of study (between 0 and 24 h) in the eyes of patients. SCBL did not cause any irritation, discomfort and foreign body sensation in the eye and eyes remained comfortable throughout the experiment. BCVA in the control group of patients was 1.00 (20/20). Mean (+/-SD) BCVA before inserting SCBL (in decimal equivalent) was 0.31 (20/60) +/- 0.18 (range 0.1- 0.66). BCVA (+/-SD) changed to 0.25 (20/80) +/- 0.18 4 h after the application of SCBL and 0.27 (20/70) +/- 0.18 24 h after the application of SCBL, with a safety index of 1.20. The mean (+/-SD) tear fluid level before application of SCBL was 11.9 +/- 5.39 h (range 3-24 mm) and changed to 13.9 +/- 5.68 h (range 5-28 mm) after 4 h of application of SCBL and 15.9 +/- 5.72 h (range 7-30 mm) after 24 h with a safety index of 13 mm. The mean (+/-SD) dissolution rate of SCBL in the control group of patients was 17.8 +/- 8.65 h (range 10-24 h) and the mean (+/-SD) dissolution rate in the experimental group was 22.2 +/- 9.29 h (range 10-24 h). We report the use of SCBL in various corneal conditions. The present study showed that SCBL has complete corneal fit and good comfort in human eyes. Transparency was maintained for a longer period along with fair visual acuity and improvement in tear fluid levels. The disadvantages of other bandage lenses presently used to treat various corneal conditions could be overcome by the use of SCBL lenses. Copyright 2008 S. Karger AG, Basel.
Diffusion of Antimicrobials Across Silicone Hydrogel Contact Lenses.
Zambelli, Alison M; Brothers, Kimberly M; Hunt, Kristin M; Romanowski, Eric G; Nau, Amy C; Dhaliwal, Deepinder K; Shanks, Robert M Q
2015-09-01
To measure the diffusion of topical preparations of moxifloxacin, amphotericin B (AmB), and polyhexamethylene biguanide (PHMB) through silicone hydrogel (SH) contact lenses (CLs) in vitro. Using an in vitro model, the diffusion of three antimicrobials through SH CLs was measured. Diffused compounds were measured using a spectrophotometer at set time points over a period of 4 hr. The amount of each diffused antimicrobial was determined by comparing the experimental value with a standard curve. A biological assay was performed to validate the CL diffusion assay by testing antimicrobial activity of diffused material against lawns of susceptible bacteria (Staphylococcus epidermidis) and yeast (Saccharomyces cerevisiae). Experiments were repeated at least two times with a total of at least four independent replicates. Our data show detectable moxifloxacin and PHMB diffusion through SH CLs at 30 min, whereas AmB diffusion remained below the limit of detection within the 4-hr experimental period. In the biological assay, diffused moxifloxacin demonstrated microbial killing starting at 20 min on bacterial lawns, whereas PHMB and AmB failed to demonstrate killing on microbial lawns over the course of the 60-min experiment. In vitro diffusion assays demonstrate limited penetration of certain anti-infective agents through SH CLs. Further studies regarding the clinical benefit of using these agents along with bandage CL for corneal pathologic condition are warranted.
Chen, Lin; Pi, Lianhong; Ke, Ning; Chen, Xinke; Liu, Qing
2017-09-01
Postoperative complications, lagophthalmos and exposure keratopathy sometimes occur after surgery for congenital blepharoptosis. Bandage contact lenses (BCL) can help prevent some ocular surface disorders. The study aims to evaluate the efficacy and safety of BCL for protection of the ocular surface in children aged 5 to 11 years after frontalis muscle flap suspension for congenital blepharoptosis. We conducted a prospective randomized clinical study of 30 eyes of 30 patients with congenital blepharoptosis consecutively enrolled at the Ophthalmology Ward of the Children's Hospital of Chongqing Medical University, China from September 1, 2016, to February 30, 2017. After frontalis muscle flap suspension surgery, patients were randomly assigned to undergo BCL application (BCL group, 15 eyes) or no BCL application (control group, 15 eyes). All patients were treated with bramycin 0.3% and polyvinyl alcohol drops after surgery. The primary outcomes were dry eye assessed by tear film break time (TFBUT), fluoresce in corneal staining (FCS) on slit-lamp on days 1, 3, and 15 postoperatively, and lower tear meniscus height (LTMH) on optical coherence tomography on days 1 and 15 postoperatively. Secondary outcomes were pairwise correlation of TFBUT, FCS and LTMH. In the BCL group, abnormal TFBUT and FCS were only found in 2 patients (13.33%) on postoperative day 15. In the control group, the incidence of dry eye assessed by TFBUT was 67.00% (10/15 eyes) on day 1, 73.33% (11/15 eyes) on day 3, and 53.33% (8/15 eyes) on day 15 (P < .001). LTMH were significantly higher in the BCL group than the control group postoperatively (P < .001). Significant positive correlations were found between LTMH and TFBUT pre-operation and on days 1 and 15 post-operation. For LTMH and FCSS (R = -0.815, P < .001), and TFBUT and FCS (R = -0.837, P < .001), the Pearson coefficient was negative on postoperative day 1, but not correlated on day 15. Silicone hydrogel BCL were safe and efficacious for protective use in children after frontalis muscle flap suspension for congenital blepharoptosis.
Corneal Regeneration After Photorefractive Keratectomy: A Review☆
Tomás-Juan, Javier; Murueta-Goyena Larrañaga, Ane; Hanneken, Ludger
2014-01-01
Photorefractive keratectomy (PRK) remodels corneal stroma to compensate refractive errors. The removal of epithelium and the ablation of stroma provoke the disruption of corneal nerves and a release of several peptides from tears, epithelium, stroma and nerves. A myriad of cytokines, growth factors, and matrix metalloproteases participate in the process of corneal wound healing. Their balance will determine if reepithelization and stromal remodeling are appropriate. The final aim is to achieve corneal transparency for restoring corneal function, and a proper visual quality. Therefore, wound-healing response is critical for a successful refractive surgery. Our goal is to provide an overview into how corneal wounding develops following PRK. We will also review the influence of intraoperative application of mitomycin C, bandage contact lenses, anti-inflammatory and other drugs in preventing corneal haze and post-PRK pain. PMID:25444646
The management of corneal trauma: advances in the past twenty-five years.
Macsai, M S
2000-09-01
Over the past quarter century, advances in our understanding of corneal anatomy, physiology, and wound healing have all played an integral role in the management of corneal trauma. As the etiologies of corneal trauma have changed, so has our understanding of the impact of injury on corneal function as it relates to visual rehabilitation. Numerous new classes of antibiotics, antiinflammatory agents, and tissue adhesives have emerged. Occlusive therapy has advanced from simple pressure patching bandage soft contact lenses and collagen shields. Surgical instrumentation, operating microscopes, viscoelastic substances, and suture materials have all improved the outcomes of corneal trauma repair. Improved understanding of the refractive properties of the cornea through topography and alternative suture techniques has helped us restore the natural corneal curvature and visual outcomes. Consequently, in the last quarter of this century our therapeutic approaches to cornea trauma, both medical and surgical, have improved.
Treatment of Refractory Filamentary Keratitis With Autologous Serum Tears.
Read, Sarah P; Rodriguez, Marianeli; Dubovy, Sander; Karp, Carol L; Galor, Anat
2017-09-01
To report a case of filamentary keratitis (FK) successfully treated with autologous serum tears and to review the pathogenesis and management of FK. Case report including high-resolution anterior segment optical coherence tomography and filament histopathology. A 61-year-old Hispanic man presented with pain and photophobia of the right eye. He was found to have a corneal epithelial defect and a small peripheral infiltrate 4 months after Laser Assisted in situ Keratomileusis. After resolution of the epithelial defect, he developed FK. Over a 4-month period, conservative management with aggressive lubrication, lid hygiene, topical corticosteroids, topical cyclosporine, bandage contact lenses, and oral doxycycline failed to resolve the corneal filaments. Notably, treatment with 20% autologous serum tears, four times daily, led to a sustained resolution of the FK within 1 week. This case demonstrates the complexity of FK management and introduces autologous serum tears as a viable management option when conservative approaches to this condition fail.
Corneal Regeneration After Photorefractive Keratectomy: A Review.
Tomás-Juan, Javier; Murueta-Goyena Larrañaga, Ane; Hanneken, Ludger
2015-01-01
Photorefractive keratectomy (PRK) remodels corneal stroma to compensate refractive errors. The removal of epithelium and the ablation of stroma provoke the disruption of corneal nerves and a release of several peptides from tears, epithelium, stroma and nerves. A myriad of cytokines, growth factors, and matrix metalloproteases participate in the process of corneal wound healing. Their balance will determine if reepithelization and stromal remodeling are appropriate. The final aim is to achieve corneal transparency for restoring corneal function, and a proper visual quality. Therefore, wound-healing response is critical for a successful refractive surgery. Our goal is to provide an overview into how corneal wounding develops following PRK. We will also review the influence of intraoperative application of mitomycin C, bandage contact lenses, anti-inflammatory and other drugs in preventing corneal haze and post-PRK pain. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Waterproof Electronic-Bandage with Tunable Sensitivity for Wearable Strain Sensors.
Jeon, Jun-Young; Ha, Tae-Jun
2016-02-03
We demonstrate high-performance wearable electronic-bandage (E-bandage) based on carbon nanotube (CNT)/silver nanoparticle (AgNP) composites covered with flexible media of fluoropolymer-coated polydimethylsiloxane (PDMS) films. The E-bandage can be used for motion-related sensors by directly attaching them to human skin, which achieves a fast and accurate electric response with high sensitivity according to the bending and stretching movements that induce changes in the conductivity. This advance in the E-bandage is realized as a result of the sensitivity that can be achieved by controlling the concentration of AgNPs in CNT pastes and by modifying the device architecture. The fluoropolymer encapsulation with hydrophobic surface characteristics allows for the E-bandage to operate in water and protects it from physical and chemical contact with the daily life conditions of the human skin. The reliability and scalability of the E-bandage as well as the compatibility with conventional microfabrication allow new possibilities to integrate flexible human-interactive nanoelectronics into mobile health-care monitoring systems combined with Internet of things (IoTs).
... Consumer Devices Consumer Products Contact Lenses Types of Contact Lenses Share Tweet Linkedin Pin it More sharing ... Orthokeratology (Ortho-K) Decorative (Plano) Contact Lenses Soft Contact Lenses Soft contact lenses are made of soft, ...
A novel medical bandage with enhanced clothing comfort
NASA Astrophysics Data System (ADS)
Oğlakcioğlu, N.; Sari, B.; Bedez Üte, T.; Marmarali, A.
2016-07-01
Compression garments are special textile products which apply a pressure on needed body zones for supporting medical, sport or casual activities. Medical bandages are a group of these garments and they have a very common usage for compression effect on legs or arms. These bandages are generally produced by using synthetic raw materials such as polyamide or polyester fibres. Medical bandages are in contact with skin. Even if the synthetic fibres are used, they may cause both comfort and health problems like allergies. Nowadays in textile sector, the expectations of clients include using of natural fibres as far as possible in all garments. Natural fibres have good advantages such as breathability, softness, moisture management ability, non-allergenic and ecologic structure and these characteristics present optimum utilization conditions. In this study, tubular medical bandages were manufactured by using core spun yarns (sheath fibres are selected as tencel, bamboo and cotton, core material is elastane) and their pressure and comfort (air and water vapour permeability) characteristics were investigated. The results indicated that the bandages have good comfort abilities beside adequate pressure values for compression effect. These garments can constitute a new production field for medical bandages with their comfort properties in addition to pressure characteristics.
The Use of Contact Lenses in Industrial Environments: An Assessment of Current Research and Policy.
ERIC Educational Resources Information Center
Connors, Terry
2001-01-01
Attempts to dispel rumors concerning contact lenses and tries to supply prudent-use practices for allowing contact lenses in industry and laboratories. Discusses federal regulations that impact the use of contact lenses in industry, policy statements from medical organizations on use of contact lenses in industrial environments, and the…
Irregular Corneas: Improve Visual Function With Scleral Contact Lenses.
de Luis Eguileor, Beatriz; Etxebarria Ecenarro, Jaime; Santamaria Carro, Alaitz; Feijoo Lera, Raquel
2018-05-01
To assess visual function in patients with irregular cornea who do not tolerate gas permeable (GP) corneal contact lenses and are fitted with GP scleral contact lenses (Rose K2 XL). In this prospective study, we analyzed 15 eyes of 15 patients who did not tolerate GP corneal contact lenses and were fitted with scleral contact lenses (Rose K2 XL). We assessed visual function using visual acuity and the visual function index (VF-14); we used the VF-14 as an indicator of patient satisfaction. The measurements were taken with the optical correction used before and 1 month after the fitting of the Rose K2 XL contact lenses. We also recorded the number of hours lenses had been worn over the first month. Using Rose K2 XL contact lenses, visual acuity was 0.06±0.07 logMAR. In all cases, visual acuity had improved compared with the measurement before fitting the lenses (0.31±0.18 logMAR; P=0.001). VF-14 scores were 72.74±12.38 before fitting of the scleral lenses, and 89.31±10.87 after 1 month of lens use (P=0.003). Patients used these scleral lenses for 9.33±2.99 comfortable hours of wear. Both visual acuity and VF-14 may improve after fitting Rose K2 XL contact lenses in patients with irregular corneas. In addition, in our patients, these lenses can be worn for a longer period than GP corneal contact lenses.
16 CFR 456.5 - Rules applicable to prescriptions for contact lenses and related issues.
Code of Federal Regulations, 2010 CFR
2010-01-01
... contact lenses and related issues. 456.5 Section 456.5 Commercial Practices FEDERAL TRADE COMMISSION TRADE... contact lenses and related issues. Rules applicable to prescriptions for contact lenses and related issues may be found at 16 CFR part 315 (Contact Lens Rule). [69 FR 40511, July 2, 2004] ...
Identification of Microorganisms Isolated From Counterfeit and Unapproved Decorative Contact Lenses.
Land, Adrian D; Penno, Katie L; Brzezinski, Jennifer L
2018-03-01
All contact lenses (corrective/noncorrective) are considered Class II or Class III medical devices under the Federal Food, Drug, and Cosmetic Act, which also states that contact lenses can only be obtained with a prescription. The Forensic Chemistry Center of the US Food & Drug Administration has examined over 300 decorative, noncorrective contact lenses obtained without a prescription. Our observations indicate that 60% of the counterfeit lenses and 27% of the unapproved lenses examined were positive for microbial contamination. Twenty-nine different brands of noncorrective contact lenses were examined, and 48% of them had at least one sample positive for microbial contamination. Each microorganism was further identified using DNA sequencing. Contaminated contact lenses are associated with numerous health risks, including ocular infections and conjunctivitis leading to permanent visual impairment or blindness. These results support the contention that acquiring contact lenses without a prescription is a considerable threat to consumer health and safety. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.
Vishnubhatla, Sravya; Borchman, Douglas; Foulks, Gary N
2012-12-01
Accelerated evaporation of tears may contribute to dry eye symptoms. It is not clear whether contact lenses decrease or increase the rate of evaporation of tears. In this study, the rates of evaporation through contact lenses (ERTCL) were measured in vitro to gain insight to this question. Contact lenses were equilibrated with various solutions to determine if they influenced ERTCL in vitro. ERTCL was measured gravimetrically. ERTCL measured in vitro for used contact lenses was about 20% faster than for buffer alone suggesting that natural tear components bound to the lenses changed the ERTCL. One natural tear component that binds to contact lenses is waxes. Equilibration of contact lenses with wax increased the ERTCL by about 30% suggesting that waxes might potentially increase ERTCL in vivo. Squalene, found in sebum and possibly meibum was infused into the contact lenses as a step toward decreasing the ERTCL. Squalene decreased ERTCL by over 60% in vitro. Soaking a contact lens in DuraSite(®) with benzalkonium chloride (BAK) did not alter the ERTCL. ERTCL were about 40% higher than the evaporation rate of DuraSite(®) alone or without BAK. In addition to lowering the ERTCL, the squalene in contact lenses could be a source of terpenoids to replace the terpenoids deficient in patients with MGD. If the ERTCL could be minimized in vivo, contact lenses could potentially be used to relieve dry eye symptoms in patients with evaporative dry eye. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
The effect of UV-blocking contact lenses as a therapy for canine chronic superficial keratitis.
Denk, Nora; Fritsche, Jens; Reese, Sven
2011-05-01
To evaluate the effect of UV-blocking soft contact lenses in treatment for chronic superficial keratitus (CSK). Twenty six dogs with CSK were treated continuously with UV-blocking contact lenses for 6 months. A contact lens was placed on one eye of each dog; the other eye remained without a lens as a control eye. After this primary study, five of the dogs were further treated and they wore then contact lenses in both eyes. Continuously, all patients were concurrently treated topically with cyclosporine. The contact lenses were changed every 4 weeks and an ophthalmic examination performed. Evaluation criteria included corneal alterations as pigmentation, edema, pannus and vascularization. To determine the transmittance characteristics of the contact lenses before and after use, 32 contact lenses were measured with a UV-vis-NIR spectrophotometer. Pigmentation increased in eyes wearing lenses and in control eyes over the evaluation period of 6 months. Corneal edema increased in the eyes wearing lenses, but remained unaffected in the control eyes. A significant difference in the incidence of pannus and the extent of corneal vascularisation could not be evaluated. Adverse effects were noted in six cases (corneal edema and vascularisation, conjunctivitis, blepharospasm). All new lenses studied reduced UV-radiation to a safe level, whereas used lenses did not maintain their transmittance characteristics. No positive effect of UV-blocking contact lenses could be proven with the study design used. © 2011 American College of Veterinary Ophthalmologists.
Reverey, Julia F; Fromme, Roland; Leippe, Matthias; Selhuber-Unkel, Christine
2014-08-01
To compare the potential of different soft contact lenses to be contaminated with Acanthamoeba castellanii as a function of material parameters and cleaning procedures. Different unworn soft hydrogel and silicone hydrogel contact lenses were incubated with human pathogenic A. castellanii. The adhesion of the acanthamoebae was investigated on the contact lenses and put into relation to their material parameters. The efficacy of a recommended contact lens cleaning procedure in reducing A. castellanii adhesion was investigated. We found that material parameters such as elastic modulus, silicone content, ionic properties and swelling do not influence the adhesion of acanthamoebae to soft contact lenses. A material parameter that influenced adhesion significantly was the water content of the lens. With increasing water content, the adhesion of acanthamoebae increased. By following the cleaning instructions of the manufacturer the contamination of the lenses with A. castellanii could be reduced to a minimum, as shown both on contact lenses and in control experiments. With this study we show that for the tested lenses, the adhesion of A. castellanii to contact lenses is independent of the silicone content of the lens, but depends nonlinearly on the water content of the lens. Furthermore, we demonstrate that applying proper lens cleaning procedures minimizes the risk of acanthamoebae adhesion to contact lenses. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Dietze, Holger H; Cox, Michael J
2003-02-01
Soft contact lenses produce a significant level of spherical aberration affecting their power on-eye. A simple model assuming that a thin soft contact lens aligns to the cornea predicts that these effects are similar on-eye and off-eye. The wavefront aberration for 17 eyes and 33 soft contact lenses on-eye was measured with a Shack-Hartmann wavefront sensor. The Zernike coefficients describing the on-eye spherical aberration of the soft contact lens were compared with off-eye ray-tracing results. Paraxial and effective lens power changes were determined. The model predicts the on-eye spherical aberration of soft contact lenses closely. The resulting power change for a +/- 7.00 D spherical soft contact lens is +/- 0.5 D for a 6-mm pupil diameter and +/- 0.1 D for a 3-mm pupil diameter. Power change is negligible for soft contact lenses corrected for off-eye spherical aberration. For thin soft contact lenses, the level of spherical aberration and the consequent power change is similar on-eye and off-eye. Soft contact lenses corrected for spherical aberration in air will be expected to be aberration-free on-eye and produce only negligibly small power changes. For soft contact lenses without aberration correction, for higher levels of ametropia and large pupils, the soft contact lens power should be determined with trial lenses with their power and p value similar to the prescribed lens. The benefit of soft contact lenses corrected for spherical aberration depends on the level of ocular spherical aberration.
Guillon, Michel; Dumbleton, Kathy; Theodoratos, Panagiotis; Patel, Trisha; Karkkainen, Tom; Moody, Kurt
2018-05-01
Contact lens wearers of Asian descent may be predisposed to experience microtrauma of the ocular surface as a result a thinner post-lens tear film and higher eyelid tension, and these effects would be anticipated to be most marked in an older population. The objective of this study was to quantify the mechanical effects of the study contact lenses on the ocular surface in a population of presbyopic contact lens wearers of Asian descent. Twenty established presbyopic contact lens wearers (hydrogel n=5, none habitual wearers of etafilcon A lenses; silicone hydrogel n=15) of Asian descent were refitted with etafilcon A multifocal daily disposable contact lenses (1-DAY ACUVUE MOIST MULTIFOCAL) for a period of 1 month of daily lens wear. The habitual modalities of wear were 45% daily disposable and 55% planned replacement. Digital photographs of the upper lid margins, nasal and temporal conjunctiva, and superior cornea were taken after 6 hr of wear of the participants' habitual contact lenses, after 1 day without contact lens wear, and after 6 hr of wear of the study contact lenses at the end of the 1-month period. The photographs were masked according to study visit and the staining extent measured using proprietary software. Lid margin staining was significantly lower with the study contact lenses (2.0±1.0 mm) than with the participants' own contact lenses (3.2±3.0 mm) after 6 hr of wear, representing a mean staining decrease of 38% (P=0.010). Lid margin staining after 6 hr of wear of the study contact lenses was not different from that measured after 1 day without contact lenses (P=0.507). Limbal staining was also significantly less with the study contact lenses than with the participants' own contact lenses after 6 hr of wear (P=0.009). There was minimal upper corneal staining, and the degree was similar with the study and habitual lenses. Etafilcon A material, worn under a daily disposable modality, was shown to reduce upper lid margin and limbal staining in presbyopic contact lens wearers of Asian descent compared with the wearers' own contact lenses. Because of the high preponderance of dry eye amongst presbyopes, material selection is of importance and consideration should be given to the lens-ocular surface interaction.
Dumbleton, Kathy; Theodoratos, Panagiotis; Patel, Trisha; Karkkainen, Tom; Moody, Kurt
2018-01-01
Introduction: Contact lens wearers of Asian descent may be predisposed to experience microtrauma of the ocular surface as a result a thinner post-lens tear film and higher eyelid tension, and these effects would be anticipated to be most marked in an older population. The objective of this study was to quantify the mechanical effects of the study contact lenses on the ocular surface in a population of presbyopic contact lens wearers of Asian descent. Methods: Twenty established presbyopic contact lens wearers (hydrogel n=5, none habitual wearers of etafilcon A lenses; silicone hydrogel n=15) of Asian descent were refitted with etafilcon A multifocal daily disposable contact lenses (1-DAY ACUVUE MOIST MULTIFOCAL) for a period of 1 month of daily lens wear. The habitual modalities of wear were 45% daily disposable and 55% planned replacement. Digital photographs of the upper lid margins, nasal and temporal conjunctiva, and superior cornea were taken after 6 hr of wear of the participants' habitual contact lenses, after 1 day without contact lens wear, and after 6 hr of wear of the study contact lenses at the end of the 1-month period. The photographs were masked according to study visit and the staining extent measured using proprietary software. Results: Lid margin staining was significantly lower with the study contact lenses (2.0±1.0 mm2) than with the participants' own contact lenses (3.2±3.0 mm2) after 6 hr of wear, representing a mean staining decrease of 38% (P=0.010). Lid margin staining after 6 hr of wear of the study contact lenses was not different from that measured after 1 day without contact lenses (P=0.507). Limbal staining was also significantly less with the study contact lenses than with the participants' own contact lenses after 6 hr of wear (P=0.009). There was minimal upper corneal staining, and the degree was similar with the study and habitual lenses. Conclusions: Etafilcon A material, worn under a daily disposable modality, was shown to reduce upper lid margin and limbal staining in presbyopic contact lens wearers of Asian descent compared with the wearers' own contact lenses. Because of the high preponderance of dry eye amongst presbyopes, material selection is of importance and consideration should be given to the lens–ocular surface interaction. PMID:27755285
[What is the role of contact lenses within the scope of electronystagmography?].
Schmäl, F; Stoll, W
1997-10-01
During electronystagmography it is necessary to correct detective vision for calibration, smooth pursuit, and saccadic eye movements. Therefore more and more people use contact lenses instead of normal glasses. Given the lack of detailed information about this phenomenon, in the current literature we decided to investigate the influence of soft contact lenses on electronystagmography. The aim of this study was to find out differences in the results of electronystagmography between using glasses or contact lenses. Our investigation involved 20 vestibular healthy human subjects with myopia. In the first part of the examination they used their contact lenses and in the second part they were wearing normal glasses. After measuring the calibration potential we wanted to see if contact lenses would increase the rate of artifacts in the electronystagmogram. Then we attempted to determine whether contact lenses would an influence on the registration of the optokinetic nystagmus. Induced saccadic eye movements were recorded and analysed. Contact lenses had a negative influence neither on the calibration potential nor on the rate of artifacts. The latency of the saccadic eye movements also showed no differences between both parts of this investigation. Only the velocity of the saccades and the gain value during the optokinetic test were reduced when glasses were used. Contact lenses may stimulate the secretory function of the lacrimal gland and thus decrease friction forces. It is also possible that the reduced image size produced or the reduction-effect of minus by glasses in near sighted persons negatively influences eyeball velocity. In summary, our study demonstrates that contact lenses do not have a negative influence on electronystagmography. Therefore electronystagmographic studies of patients with contact lenses are permissible for purposes of documenting a medical opinion.
Biocompatibility and light transmission of liposomal lenses.
Danion, Anne; Doillon, Charles J; Giasson, Claude J; Djouahra, Saliha; Sauvageau, Patrick; Paradis, Renée; Vermette, Patrick
2007-10-01
To validate the biocompatibility and transmittance properties of contact lenses bearing intact liposomes. These liposomal lenses loaded with therapeutics can be used as ophthalmic drug delivery systems. The biocompatibility of soft contact lenses, coated with liposomes was evaluated through in vitro direct and indirect cytocompatibility assays on human corneal epithelial cells, on reconstructed human corneas and on ex vivo rabbit corneas. The direct and indirect transmission spectra of liposome-covered lenses were also evaluated to test if they transmit all wavelengths of the ultraviolet-visible spectrum, to thereby fulfill their optical function, without gross alteration of the colors perception and with a minimum of light dispersion. Contact lenses bearing layers of stable liposomes did not induce any significant changes in cell viability and in cell growth, compared with lenses bearing no liposome. Elution assays revealed that no cytotoxic compound leaks from the lenses whether bearing liposomes or not. Histological analyses of reconstructed human corneas and ex vivo rabbit corneas directly exposed to liposomal lenses revealed neither alteration to the cell nor to the tissue structures. Contact lenses bearing layers of liposomes did not significantly affect light transmission compared with control lenses without liposome at the wavelength of maximal photopic sensitivity, i.e., 550 nm. In addition, the contact lenses afford more eye protection in the ultraviolet spectrum, compared with the control lenses. Liposomal contact lenses are biocompatible and their transmittance properties are not affected in the visible light range.
Scleral contact lenses for the management of complicated ptosis.
Katsoulos, Konstantinos; Rallatos, Gerasimos Livir; Mavrikakis, Ioannis
2018-06-01
To present the management of three patients suffering from ptosis of various etiologies, with scleral contact lenses. Three patients (five eyes) with ptosis resulting from levator dehiscence due to long-term rigid gas permeable contact lens wear for keratoconus, phthisis bulbi, and myopathy due to Kearns-Sayre syndrome were identified during a 2-year period. They were fitted with scleral contact lenses in order to provide cosmesis by lifting the upper eyelid with the bulk of the lens, and simultaneously provide vision correction where applicable. The scleral contact lenses provided comfortable wear, significantly improved cosmesis as both palpebral aperture and marginal reflex distance were increased, and visual acuity was also subjectively and objectively improved. Two of the patients opted for the scleral contact lenses, whereas the parents of the third patient, a 10-year-old girl with Kearns-Sayre syndrome, chose to undergo ptosis surgery due to handling issues of the scleral contact lenses. Scleral contact lenses can be a useful addition to the treatment option for patients with complicated ptosis.
Extended release of hyaluronic acid from hydrogel contact lenses for dry eye syndrome.
Maulvi, Furqan A; Soni, Tejal G; Shah, Dinesh O
2015-01-01
Current dry eye treatment includes delivering comfort enhancing agents to the eye via eye drops, but low residence time of eye drops leads to low bioavailability. Frequent administration leads to incompliance in patients, so there is a great need for medical device such as contact lenses to treat dry eye. Studies in the past have demonstrated the efficacy of hyaluronic acid (HA) in the treatment of dry eyes using eye drops. In this paper, we present two methods to load HA in hydrogel contact lenses, soaking method and direct entrapment. The contact lenses were characterized by studying their optical and physical properties to determine their suitability as extended wear contact lenses. HA-laden hydrogel contact lenses prepared by soaking method showed release up to 48 h with acceptable physical and optical properties. Hydrogel contact lenses prepared by direct entrapment method showed significant sustained release in comparison to soaking method. HA entrapped in hydrogels resulted in reduction in % transmittance, sodium ion permeability and surface contact angle, while increase in % swelling. The impact on each of these properties was proportional to HA loading. The batch with 200-μg HA loading showed all acceptable values (parameters) for contact lens use. Results of cytotoxicity study indicated the safety of hydrogel contact lenses. In vivo pharmacokinetics studies in rabbit tear fluid showed dramatic increase in HA mean residence time and area under the curve with lenses in comparison to eye drop treatment. The study demonstrates the promising potential of delivering HA through contact lenses for the treatment of dry eye syndrome.
Release of betaine and dexpanthenol from vitamin E modified silicone-hydrogel contact lenses.
Hsu, Kuan-Hui; de la Jara, Percy Lazon; Ariyavidana, Amali; Watling, Jason; Holden, Brien; Garrett, Qian; Chauhan, Anuj
2015-03-01
To develop a contact lens system that will control the release of an osmoprotectant and a moisturizing agent with the aim to reduce symptoms of ocular dryness. Profiles of the release of osmoprotectant betaine and moisturizing agent dexpanthenol from senofilcon A and narafilcon B contact lenses were determined in vitro under sink conditions. Both types of lenses were also infused with vitamin E to increase the duration of drug release due to the formation of the vitamin E diffusion barriers in the lenses. The release profiles from vitamin E-infused lenses were compared with those from the control lenses. Both dexpanthenol and betaine are released from commercial silicone hydrogel lenses for only about 10 min. Vitamin E loadings into contact lenses at about 20-23% can increase the release times to about 10 h, which is about 60 times larger compared to the control unmodified lenses. Vitamin E-loaded silicone hydrogel contact lenses released betaine and dexpanthenol in a controlled fashion.
Xu, Jinku; Li, Xinsong; Sun, Fuqian
2011-02-01
The purpose of this work was to evaluate the usefulness of silicone hydrogel contact lenses loaded with ketotifen fumarate for ocular drug delivery. First, silicone contact lenses were prepared by photopolymerization of bitelechelic methacrylated polydimethylsiloxanes macromonomer, 3-methacryloxypropyltris(trimethylsiloxy)silane, and N,N-dimethylacrylamide using ethylene glycol dimethacrylate as a cross-linker and Darocur 1173 as an initiator followed by surface plasma treatment. Then, the silicone hydrogel matrices of the contact lenses were characterized by equilibrium swelling ratio (ESR), tensile tests, ion permeability, and surface contact angle. Finally, the contact lenses were loaded with ketotifen fumarate by pre-soaking in drug solution to evaluate drug loading capacity, in vitro and in vivo release behavior of the silicone contact lenses. The results showed that ESR and ion permeability increase, and the surface contact angle and tensile strength decreased with the increase of DMA component in the silicone hydrogel. The drug loading and in vitro releases were dependent on the hydrogel composition of hydrophilic/hydrophobic phase of the contact lenses. In rabbit eyes, the pre-soaked contact lenses sustained ketotifen fumarate release for more than 24 h, which leads to a more stable drug concentration and a longer mean retention time in tear fluid than that of eye drops of 0.05%.
Melimine-Coated Antimicrobial Contact Lenses Reduce Microbial Keratitis in an Animal Model.
Dutta, Debarun; Vijay, Ajay K; Kumar, Naresh; Willcox, Mark D P
2016-10-01
To determine the ability of antimicrobial peptide melimine-coated contact lenses to reduce the incidence of microbial keratitis (MK) in a rabbit model of contact lens wear. In vitro antimicrobial activity of melimine-coated contact lenses was determined against Pseudomonas aeruginosa by viable count and a radiolabeled assay. The amount of lipopolysaccharide (LPS) associated with bacteria bound to melimine-coated and control lenses was determined. Ocular swabs from rabbit eyes were collected for assessment of ocular microflora. A rabbit model for MK was developed that used overnight wear of contact lenses colonized by P. aeruginosa in the absence of a corneal scratch. During lens wear, detailed ocular examinations were performed, and the incidence of MK was investigated. Bacteria associated with worn lenses and infected corneas were determined by viable plate count. Inhibition in viable and total P. aeruginosa adhesion by melimine-coated contact lenses was 3.1 log10 and 0.4 log10, respectively. After colonization, the amount of LPS on lenses was approximately the same with or without melimine. Gram-positive bacteria were found in all the ocular swabs followed by fungus (42%). Melimine-coated lens wear was protective and significantly (odds ratio 10.12; P = 0.012) reduced the incidence of P. aeruginosa-driven MK in the rabbit model. The antimicrobial lenses were associated with significantly (P < 0.001) lower ocular scores, indicating improved ocular signs compared with controls. This study showed that contaminated contact lenses can produce MK without corneal epithelial defect in an animal model. Melimine-coated contact lenses reduced the incidence of MK associated with P. aeruginosa in vivo. Development of MK requires viable bacteria adherent to contact lenses, and bacterial debris adherent at the lens surface did not cause keratitis.
Maulvi, Furqan A; Choksi, Harsh H; Desai, Ankita R; Patel, Akanksha S; Ranch, Ketan M; Vyas, Bhavin A; Shah, Dinesh O
2017-09-01
In the present work a novel cyclosporine-loaded Eudragit S100 (pH-sensitive) nanoparticles-laden contact lenses were designed to provide sustained release of cyclosporine at therapeutic rates, without leaching of drug during sterilization and storage period (shelf life). The nanoparticles were prepared by Quasi-emulsion solvent diffusion technique using different weight ratios of cyclosporine to Eudragit S100. The contact lenses with direct drug entrapment were also fabricated (DL-50) for comparison. The percentage swelling and optical transparency of nanoparticles-laden contact lenses were improved in comparison to DL-50 lenses. The nanoparticles-laden contact lenses showed sustained drug release profiles, with inverse relationship to the amount of nanoparticles loaded in the contact lenses. It was interesting to note that nanoparticles form nanochannels/cavities after dissolution of Eudragit S 100 in tear fluid pH=7.4 (in vitro release study). This followed the precipitation of drug in hydrogel matrix of contact lenses. As the amount of nanoparticles loading increased, more number of cavities were formed, which caused the formation of large cavities in contact lens matrix. This in turn precipitated the drug. The nanoparticles-laden contact lenses with 1:1 (drug: Eudragit) weight ratio showed the most promising results of sustaining the drug release up to 156h, without affecting optical and physical properties of contact lenses. Packaging study confirmed that the drug was not leached in packaging solution (buffer, pH=6.5) from nanoparticles-laden lenses during shelf life period. In-vivo study in rabbit tear fluid showed sustained release up to 14days. The study revealed the application of pH-sensitive nanoparticles-laden contact lenses for controlled release of cyclosporine without altering the optical and physical properties of lens material. Copyright © 2017 Elsevier B.V. All rights reserved.
Material properties that predict preservative uptake for silicone hydrogel contact lenses.
Green, J Angelo; Phillips, K Scott; Hitchins, Victoria M; Lucas, Anne D; Shoff, Megan E; Hutter, Joseph C; Rorer, Eva M; Eydelman, Malvina B
2012-11-01
To assess material properties that affect preservative uptake by silicone hydrogel lenses. We evaluated the water content (using differential scanning calorimetry), effective pore size (using probe penetration), and preservative uptake (using high-performance liquid chromatography with spectrophotometric detection) of silicone and conventional hydrogel soft contact lenses. Lenses grouped similarly based on freezable water content as they did based on total water content. Evaluation of the effective pore size highlighted potential differences between the surface-treated and non-surface-treated materials. The water content of the lens materials and ionic charge are associated with the degree of preservative uptake. The current grouping system for testing contact lens-solution interactions separates all silicone hydrogels from conventional hydrogel contact lenses. However, not all silicone hydrogel lenses interact similarly with the same contact lens solution. Based upon the results of our research, we propose that the same material characteristics used to group conventional hydrogel lenses, water content and ionic charge, can also be used to predict uptake of hydrophilic preservatives for silicone hydrogel lenses. In addition, the hydrophobicity of silicone hydrogel contact lenses, although not investigated here, is a unique contact lens material property that should be evaluated for the uptake of relatively hydrophobic preservatives and tear components.
Keith, D; Hong, B; Christensen, M
1997-05-01
A quick, simple, and efficient extraction technique was developed for the removal of protein from soft hydrophilic contact lenses. An extraction solvent consisting of a 50:50 mix of 0.2% trifluoroacetic acid and acetonitrile was used to remove protein from in vitro laboratory-deposited and human-worn contact lenses. The protein removed was analyzed using HPLC, bicinchoninic acid (BCA) analysis, and SDS-PAGE gel electreophoresis. Extraction efficiency for lysozyme from laboratory-deposited Group IV lenses was determined to be approximately 100%. Group IV human-worn contact lenses were extracted and analyzed for lysozyme by HPLC and total protein by bicinchoninic acid (BCA) analysis. Groups I, II, III, and IV contact lenses deposited with an artificial tear protein solution and human-worn lenses were extracted and analyzed by SDS-PAGE gel electreophoresis and micro-BCA. The ACN/TFA procedure offers a simple, quick, and efficient extraction technique for removal of protein from contact lenses for subsequent analysis.
Fabricating customized hydrogel contact lens
NASA Astrophysics Data System (ADS)
Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.
2016-10-01
Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.
Fabricating customized hydrogel contact lens
Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.
2016-01-01
Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies. PMID:27748361
A Laboratory Assessment of Factors That Affect Bacterial Adhesion to Contact Lenses
Dutta, Debarun; Willcox, Mark DP
2013-01-01
Adhesion of pathogenic microbes, particularly bacteria, to contact lenses is implicated in contact lens related microbial adverse events. Various in vitro conditions such as type of bacteria, the size of initial inoculum, contact lens material, nutritional content of media, and incubation period can influence bacterial adhesion to contact lenses and the current study investigated the effect of these conditions on bacterial adhesion to contact lenses. There was no significant difference in numbers of bacteria that adhered to hydrogel etafilcon A or silicone hydrogel senofilcon A contact lenses. Pseudomonas aeruginosa adhered in higher numbers compared to Staphylococcus aureus. Within a genera/species, adhesion of different bacterial strains did not differ appreciably. The size of initial inoculum, nutritional content of media, and incubation period played significant roles in bacterial adhesion to lenses. A set of in vitro assay conditions to help standardize adhesion between studies have been recommended. PMID:24833224
Occlusion properties of prosthetic contact lenses for the treatment of amblyopia.
Collins, Randall S; McChesney, Megan E; McCluer, Craig A; Schatz, Martha P
2008-12-01
The efficacy of opaque contact lenses as occlusion therapy for amblyopia has been established in the literature. Prosthetic contact lenses use similar tints to improve cosmesis in scarred or deformed eyes and may be an alternative in occlusion therapy. To test this idea, we determined the degree of vision penalization elicited by prosthetic contact lenses and their effect on peripheral fusion. We tested 19 CIBA Vision DuraSoft 3 Prosthetic soft contact lenses with varying iris prints, underprints, and opaque pupil sizes in 10 volunteers with best-corrected Snellen distance visual acuity of 20/20 or better in each eye. Snellen visual acuity and peripheral fusion using the Worth 4-Dot test at near were measured on each subject wearing each of the 19 lenses. Results were analyzed with 3-factor analysis of variance. Mean visual acuity through the various lenses ranged from 20/79 to 20/620. Eight lenses allowed preservation of peripheral fusion in 50% or more of the subjects tested. Iris print pattern and opaque pupil size were significant factors in determining visual acuity (p < 0.05). Sufficient vision penalization can be achieved to make occlusion with prosthetic contact lenses a viable therapy for amblyopia. The degree of penalization can be varied and different iris print patterns and pupil sizes, using peripheral fusion, can be preserved with some lenses. Prosthetic contact lenses can be more cosmetically appealing and more tolerable than other amblyopia treatment modalities. These factors may improve compliance in occlusion therapy.
Bacterial adhesion to conventional hydrogel and new silicone-hydrogel contact lens materials.
Kodjikian, Laurent; Casoli-Bergeron, Emmanuelle; Malet, Florence; Janin-Manificat, Hélène; Freney, Jean; Burillon, Carole; Colin, Joseph; Steghens, Jean-Paul
2008-02-01
As bacterial adhesion to contact lenses may contribute to the pathogenesis of keratitis, the aim of our study was to investigate in vitro adhesion of clinically relevant bacteria to conventional hydrogel (standard HEMA) and silicone-hydrogel contact lenses using a bioluminescent ATP assay. Four types of unworn contact lenses (Etafilcon A, Galyfilcon A, Balafilcon A, Lotrafilcon B) were incubated with Staphylococcus epidermidis (two different strains) and Pseudomonas aeruginosa suspended in phosphate buffered saline (PBS). Lenses were placed with the posterior surface facing up and were incubated in the bacterial suspension for 4 hours at 37 degrees C. Bacterial binding was then measured and studied by bioluminescent ATP assay. Six replicate experiments were performed for each lens and strain. Adhesion of all species of bacteria to standard HEMA contact lenses (Etafilcon A) was found to be significantly lower than that of three types of silicone-hydrogel contact lenses, whereas Lotrafilcon B material showed the highest level of bacterial binding. Differences between species in the overall level of adhesion to the different types of contact lenses were observed. Adhesion of P. aeruginosa was typically at least 20 times greater than that observed with both S. epidermidis strains. Conventional hydrogel contact lenses exhibit significantly lower bacterial adhesion in vitro than silicone-hydrogel ones. This could be due to the greater hydrophobicity but also to the higher oxygen transmissibility of silicone-hydrogel lenses.
Contact Lenses in the Laboratory.
ERIC Educational Resources Information Center
Kingston, David W.
1981-01-01
Summarizes results of a three-item questionnaire returned by 43 Michigan institutions expressing views on wearing contact lenses in chemical laboratories. Questions focused on eye protection, type of protection, and use of contact lenses. (SK)
Practitioner influence on contact lens prescribing in the UK.
Efron, Nathan; Morgan, Philip B
2009-08-01
Contact lenses are mainly fitted by registered optometrists and contact lens opticians in the UK. Data we have gathered from annual contact lens fitting surveys over the past 12 years indicate that, on average, registered optometrists and contact lens opticians undertake 3.2 and 7.1 contact lens fits per week (p<0.0001). More experienced practitioners tend to fit older patients. Practitioners fitting more lenses per year tend to fit a higher proportion of soft lenses. Contact lens opticians tend to fit a higher proportion of patients with planned replacement and daily disposable lenses compared with optometrists.
Anstey, A; Taylor, D; Chalmers, I; Ansari, E
1999-10-01
Nine brands of contact lens marketed as "UV protective" were tested for ultraviolet (UV) transmission in order to assess potential suitability for psoralen-sensitised patients. UV-transmission characteristics of hydrated lenses was tested with a Bentham monochromator spectro-radiometer system. All lenses showed minimal transmission loss in the visible band. The performance of the nine lenses was uniform for ultraviolet B radiation with negligible transmission, but showed variation in transmission for ultraviolet A radiation. None of the lenses complied with UV-transmission criteria used previously to assess UV-blocking spectacles. Only two lenses had UV-blocking characteristics which came close to the arbitrary criteria used. The performance of ordinary soft and hard lenses was very similar, with negligible blocking of UV radiation. None of the nine contact lenses marketed as "UV protective" excluded sufficient UVA to comply with criteria in current use to assess UV protection in spectacles for psoralen-sensitised patients. However, the improved UV-blocking characteristics of contact lenses identified in this paper compared to previous studies suggests that such a contact lens will soon become available. Meanwhile, contact lens-wearing systemically sensitised PUVA patients should continue to wear approved spectacles for eye protection whilst photosensitised with psoralen.
Transmittance of tinted and UV-blocking disposable contact lenses.
Harris, M G; Haririfar, M; Hirano, K Y
1999-03-01
Tinted and ultraviolet (UV)-blocking disposable contact lenses have become increasingly popular over the last decade. Wearers of UV-blocking contact lenses could benefit greatly by protecting their eyes from potential UV radiation damage. A Uvikon 930 dual beam spectrophotometer was used to measure three enhancement-tinted lenses (royal blue, evergreen, and aqua), two types of UV-blocking lenses, and two types of non-UV-blocking lenses. Enhancement-tinted lenses did show a decrease in transmittance at certain wavelengths on the visible spectrum, but they did not reduce the transmittance of UV radiation to the extent of the UV-blocking lenses designed specifically for this purpose.
Jacobson, Steven D.
2014-08-19
Certain examples provide optical contact micrometers and methods of use. An example optical contact micrometer includes a pair of opposable lenses to receive an object and immobilize the object in a position. The example optical contact micrometer includes a pair of opposable mirrors positioned with respect to the pair of lenses to facilitate viewing of the object through the lenses. The example optical contact micrometer includes a microscope to facilitate viewing of the object through the lenses via the mirrors; and an interferometer to obtain one or more measurements of the object.
... that you think may be caused by contact lenses. Bepotastine eye drops contain benzalkonium chloride, which can be absorbed ... you are wearing contact lenses. Remove your contact lenses before you use bepotastine eye drops and do not replace them for at ...
Halloween Safety: Costumes, Candy, and Colored Contact Lenses
... Consumer Updates Halloween Safety: Costumes, Candy, and Colored Contact Lenses Share Tweet Linkedin Pin it More sharing ... or witch, poor costume choices—including decorative (colored) contact lenses and flammable costumes—and face paint allergies ...
Marx, Sebastian; Lauenborg, Bo; Kern, Jami R
2018-02-06
To evaluate the tolerability of and subject and investigator satisfaction with delefilcon A (DAILIES TOTAL1 ® ) daily disposable contact lenses in first-time contact lens wearers. This European multicenter, open-label, single-arm, two-week trial enrolled first-time contact lens wearers and fitted them with delefilcon A contact lenses. Assessments were made at dispensing and at Weeks 1 and 2. Subject-reported outcomes included comfort, quality of vision, convenience, and intent to purchase, which were ranked by agreement responses. Investigator-reported outcomes included slit-lamp biomicroscopy findings and lens fit satisfaction. Ninety-two subjects were included in the per protocol dataset. Mean scores at Weeks 1 and 2 for subject-reported quality of vision and ocular comfort were significantly higher with delefilcon A contact lenses than with the subjects' habitual spectacles during the day, at the end of the day, and overall (all p ≤ 0.02). Ninety-one percent of subjects reported that their study lenses were more comfortable than expected, 98% agreed that they were convenient to use, and 92% were interested in purchasing the lenses (all p < 0.001). Investigators reported that study lenses had an acceptable fit in at least 97% of subjects. Practitioners can expect favorable outcomes when transitioning first-time contact lens wearers from spectacles to delefilcon A daily disposable contact lenses. Copyright © 2017. Published by Elsevier Ltd.
[Contact lenses for children. Indications and results].
Steinbach, P D; Nover, A
1976-03-18
If it is necessary to prescribe contact lenses for children, this correction should be made as soon as possible. As a consequence of the development of soft (hydrophile) lenses, the above mentioned group of patients has increased considerably. In any case, a monolateral aphakia as well as a manifest anisometropia should be corrected by a contact lense to avoid amblyopia, heterotropia and loss of stereoscopic vision. Usually soft lenses are well tolerated, so that patients suffering from aphakia as well as hyperopia should always use this type of lense. Nevertheless, the hard lense still has its indication in treating myopia and high astigmatism.
... with a bandage. Don't share razors, towels, uniforms, or other items that come into contact with ... family member to another (or among students at school), or if two or more family members have ...
Plasma surface modification of rigid contact lenses decreases bacterial adhesion.
Wang, Yingming; Qian, Xuefeng; Zhang, Xiaofeng; Xia, Wei; Zhong, Lei; Sun, Zhengtai; Xia, Jing
2013-11-01
Contact lens safety is an important topic in clinical studies. Corneal infections usually occur because of the use of bacteria-carrying contact lenses. The current study investigated the impact of plasma surface modification on bacterial adherence to rigid contact lenses made of fluorosilicone acrylate materials. Boston XO and XO2 contact lenses were modified using plasma technology (XO-P and XO2-P groups). Untreated lenses were used as controls. Plasma-treated and control lenses were incubated in solutions containing Staphylococcus aureus or Pseudomonas aeruginosa. MTT colorimetry, colony-forming unit counting method, and scanning electron microscopy were used to measure bacterial adhesion. MTT colorimetry measurements showed that the optical density (OD) values of XO-P and XO2-P were significantly lower than those of XO and XO2, respectively, after incubation with S. aureus (P < 0.01). The OD value of XO-P was also much lower than that of XO after incubation with P. aeruginosa (P < 0.01). Colony-forming unit counting revealed that a significantly lower number of bacterial colonies attached to the XO-P versus XO lenses and to the XO2-P versus XO2 lenses incubated with S. aureus (P < 0.01). Fewer bacterial colonies attached to the XO-P versus XO lenses incubated with P. aeruginosa (P < 0.01). Further, scanning electron microscopy suggested different bacterial adhesion morphology on plasma-treated versus control lenses. Plasma surface modification can significantly decrease bacterial adhesion to fluorosilicone acrylate contact lenses. This study provides important evidence of a unique benefit of plasma technology in contact lens surface modification.
Willcox, Mark; Sharma, Savitri; Naduvilath, Thomas J; Sankaridurg, Padmaja R; Gopinathan, Usha; Holden, Brien A
2011-03-01
To determine whether carriage of microbes on the contact lens or ocular surfaces during extended wear (EW) with soft hydroxyethyl methacrylate (HEMA)-based contact lenses predisposes the wearer to adverse events. Participants (non-contact lens wearers) were enrolled in a clinical study involving wear of HEMA-based hydrogel lenses on a six night EW basis with weekly replacement. Type and number of bacteria colonizing the lower lid margins, upper bulbar conjunctiva, and contact lenses during EW after one night, 1 week, 1 month, and thereafter every 3 months for 3.5 years were determined. The association of bacteria with adverse responses was compared between carriers (defined as having significant microbes cultured from two or more samples with 1 year) and noncarriers, and the strength of the association was estimated using multivariate logistic regression. Carriers of gram-positive bacteria on lenses (particularly coagulase negative staphylococci or Corynebacterium spp.) were approximately three and eight times more likely to develop contact lens-induced peripheral ulcers (CLPUs) and asymptomatic infiltrates (AIs), respectively. Staphylococcus aureus was most frequently isolated from lenses during CLPU. Carriers of gram-negative bacteria on lenses were five times more likely to develop contact lens-induced acute red eye (CLARE). Haemophilus influenzae was isolated most frequently from lenses during CLARE and AI events. Bacterial carriage on contact lenses during EW predisposes the wearer to the development of corneal inflammatory events including CLARE, CLPU, and AI.
Mathews, Steven M; Spallholz, Julian E; Grimson, Mark J; Dubielzig, Richard R; Gray, Tracy; Reid, Ted W
2006-08-01
Although silicone hydrogel materials have produced many corneal health benefits to patients wearing contact lenses, bacteria that cause acute red eye or corneal ulcers are still a concern. A coating that inhibits bacterial colonization while not adversely affecting the cornea should improve the safety of contact lens wear. A covalent selenium (Se) coating on contact lenses was evaluated for safety using rabbits and prevention of bacterial colonization of the contact lenses in vitro. Contact lenses coated with Se were worn on an extended-wear schedule for up to 2 months by 10 New Zealand White rabbits. Corneal health was evaluated with slit-lamp biomicroscopy, pachymetry, electron microscopy, and histology. Lenses worn by the rabbits were analyzed for protein and lipid deposits. In addition, the ability of Se to block bacterial colonization was tested in vitro by incubating lenses in a Pseudomonas aeruginosa broth followed by scanning electron microscopy of the contact lens surface. The covalent Se coating decreased bacterial colonization in vitro while not adversely affecting the corneal health of rabbits in vivo. The Se coating produced no noticeable negative effects as observed with slit-lamp biomicroscopy, pachymetry, electron microscopy, and histology. The Se coating did not affect protein or lipid deposition on the contact lenses. The data from this pilot study suggest that a Se coating on contact lenses might reduce acute red eye and bacterial ulceration because of an inhibition of bacterial colonization. In addition, our safety tests suggest that this positive effect can be produced without an adverse effect on corneal health.
Nilagiri, Vinay Kumar; Metlapally, Sangeetha; Kalaiselvan, Parthasarathi; Schor, Clifton M; Bharadwaj, Shrikant R
2018-04-01
This study showed an improvement in three-dimensional depth perception of subjects with bilateral and unilateral keratoconus with rigid gas-permeable (RGP) contact lens wear, relative to spectacles. This novel information will aid clinicians to consider RGP contact lenses as a management modality in keratoconic patients complaining of depth-related difficulties with their spectacles. The aim of this study was to systematically compare changes in logMAR acuity and stereoacuity from best-corrected spherocylindrical spectacles to RGP contact lenses in bilateral and unilateral keratoconus vis-à-vis age-matched control subjects. Monocular and binocular logMAR acuity and random-dot stereoacuity were determined in subjects with bilateral (n = 30; 18 to 24 years) and unilateral (n = 10; 18 to 24 years) keratoconus and 20 control subjects using standard psychophysical protocols. Median (25th to 75th interquartile range) monocular (right eye) and binocular logMAR acuity and stereoacuity improved significantly from spectacles to RGP contact lenses in the bilateral keratoconus cohort (P < .001). Only monocular logMAR acuity of affected eye and stereoacuity improved from spectacles to RGP contact lenses in the unilateral keratoconus cohort (P < .001). There was no significant change in the binocular logMAR acuity from spectacles to RGP contact lenses in the unilateral keratoconus cohort. The magnitude of improvement in binocular logMAR acuity and stereoacuity was also greater for the bilateral compared with the unilateral keratoconus cohort. All outcome measures of cases with RGP contact lenses remained poorer than control subjects (P < .001). Binocular resolution and stereoacuity improve from spectacles to RGP contact lenses in bilateral keratoconus, whereas only stereoacuity improves from spectacles to RGP contact lenses in unilateral keratoconus. The magnitude of improvement in visual performance is greater for the binocular compared with the unilateral keratoconus cohort.
Ocular Drug Delivery through pHEMA-Hydrogel Contact Lenses Co-Loaded with Lipophilic Vitamins
NASA Astrophysics Data System (ADS)
Lee, Dasom; Cho, Seungkwon; Park, Hwa Sung; Kwon, Inchan
2016-09-01
Ocular drug delivery through hydrogel contact lenses has great potential for the treatment of ocular diseases. Previous studies showed that the loading of lipophilic vitamin E to silicone-hydrogel contact lenses was beneficial in ocular drug delivery. We hypothesized that vitamin E loading to another type of popular hydrogel contact lenses, pHEMA-hydrogel contact lenses, improves ocular drug delivery by increasing the drug loading or the duration of drug release. Loading of vitamin E to pHEMA-hydrogel contact lenses significantly increased the loading of a hydrophilic drug surrogate (Alexa Fluor 488 dye) and two hydrophilic glaucoma drugs (timolol and brimonidine) to the lenses by 37.5%, 19.1%, and 18.7%, respectively. However, the release duration time was not significantly altered. Next, we hypothesized that the lipophilic nature of vitamin E attributes to the enhanced drug loading. Therefore, we investigated the effects of co-loading of another lipophilic vitamin, vitamin A, on drug surrogate delivery. We found out that vitamin A loading also increased the loading of the drug surrogate to pHEMA-hydrogel contact lenses by 30.3%. Similar to vitamin E loading, vitamin A loading did not significantly alter the release duration time of the drug or drug surrogate.
Allergic manifestations of contact lens wearing.
Solomon, Abraham
2016-10-01
Contact lens-induced papillary conjunctivitis (CLPC) is a common ocular allergic disease in contact lens wearers. In its more severe form, it can cause giant papillary conjunctivitis, resulting in contact lens intolerance and the need to discontinue the use of contact lenses. This review presents the pathogenesis, clinical manifestations and management guidelines of this common disorder. Different types of contact lenses are associated with differences in the severity of CLPC. Refitting patients with silicone hydrogel contact lenses or with daily disposable contact lenses may improve the signs and symptoms of CLPC. The recent introduction of the topical immunomodulatory agent tacrolimus in other severe allergic eye diseases may apply in suppressing the allergic inflammation in CLPC as well. CLPC is a common ocular disorder in contact lens wearers, with a significant impact on the quality of vision. It should be promptly recognized by healthcare practitioners and managed by modifications of the types and wearing schedules of contact lenses, as well as novel treatment options with topical immunomodulators.
Contact lenses to slow progression of myopia.
Sankaridurg, Padmaja
2017-09-01
The prevalence of myopia has been steadily rising, with 28 per cent of the global population said to be affected in 2010 and to rise to affect nearly 50 per cent by 2050. Increasing levels of myopia increase the risk of vision impairment and in particular, high myopia is associated with the risk of serious and permanent visual disability due to associated sight-threatening complications. To stem the burden associated with higher levels of myopia, there are efforts to slow the progression of myopia, and several optical and pharmaceutical strategies have been found useful in slowing myopia to varying degrees. More recently, numerous multifocal soft contact lenses and extended depth of focus soft contact lenses (collectively referred to as myopia control contact lenses) were found effective in slowing myopia. As opposed to overnight orthokeratology, myopia control contact lenses are worn during the day and the hypotheses proposed to explain the efficacy of these lenses are generally based on the premise that the stimulus for eye growth is a defocused retinal image with hyperopic blur either centrally or peripherally. Although the individual power profiles of the lenses vary, the contact lens generally incorporates 'positive power' to reduce the hyperopic blur and/or impose myopic defocus or in the case of the extended depth of focus lens, has a power profile designed to optimise retinal image quality for points on or in front of the retina. The use of soft contact lenses as a platform for myopia control offers an exciting and effective avenue to manage myopia but there is a need for further research on issues such as the mechanism underlying control of myopia, improving efficacy with lenses, and understanding rebound on discontinuation. More significantly, although contact lenses are generally safe and improve quality of life in older children, one of the major challenges for improved uptake and acceptance of contact lenses centres on the perceived risk of complications with lens wear. This issue needs to be addressed. © 2017 Optometry Australia.
Gaiser, Hilary; Ho, Connie; Janier, Nicole; Wee, Amy; Johnson, Catherine; Watanabe, Ronald
2017-03-01
To describe practitioner experiences regarding ocular complications in patients wearing decorative contact lenses, and to investigate the compliance of unauthorized distributors of decorative contact lenses to current Food and Drug Administration (FDA) and Federal Trade Commission (FTC) regulations. Also, to provide data to support a more targeted public health approach to reducing the incidence of illegal contact lens sales and associated ocular complications. An institutional review board-approved online survey was distributed through mass email to a list of 98 optometrists in the Boston, MA area. Concurrently, an empirical evaluation of independent, online decorative contact lens sellers who were not associated with FDA-approved contact lens manufacturers was performed to determine their adherence to FDA and FTC guidelines. The first 18 noncoincidental websites that resulted from a Google search for "costume contact lens sellers" and "cosmetic contact lens sellers" were examined as to the brands and parameters of lenses being sold, whether or not a valid prescription was required or verified, and if consumer education was provided. Twenty-two optometrists completed the online survey. Seventy-seven percent of respondents reported having patients with complications from decorative contact lenses that were purchased both legally and illegally. The most common age group for complications was 18 to 25 years (61%). One third of complications were seen in first-time lens wearers, half of whom never received proper care instructions or were unaware that care instructions existed. One quarter of the lenses were purchased illegally with unlicensed stores being the most common place of purchase. Of the 18 online sites examined, 72% of sellers failed to adhere to FTC and FDA regulations. A significant number of individuals who obtain contact lenses illegally from unauthorized sources are young adults. Most unauthorized sellers reviewed did not adhere to the proper protocol for selling contact lenses or instruct their customers on proper lens wear and care. A significant percentage of optometrists responding to the survey reported complications associated with contact lenses purchased through unauthorized sources, suggesting that the risk of contact lens-related complications increases when the lenses are purchased from one of these sources.
Discrimination against contact lens wearers.
Blais, B R
1998-10-01
Employers' attitudes toward the use of contact lenses at work have become less discriminatory as lenses have improved and numerous studies have demonstrated their safety, provided that additional personal protective equipment is used when necessary. In 1994, the Occupational Safety and Health Administration published its relevant Standard (29 CFR 1910), stating that "contact lenses do not pose additional hazards to the wearer...". Accommodations required by wearers of contact lenses must comply with Title I of the Americans with Disabilities Act. However, many companies still oppose their use. The recently published policy of the American College of Occupational and Environmental Medicine and the American Academy of Ophthalmology on the use of contact lenses should lead to their wider acceptance. Elements of a corporate contact lens policy are outlined. International aspects are summarized as well.
Danion, Anne; Arsenault, Isabelle; Vermette, Patrick
2007-09-01
In vitro methods to evaluate antibacterial activity were used with contact lenses bearing levofloxacin-loaded liposomes developed for the prevention and treatment of bacterial ocular infections such as keratitis. Levofloxacin was incorporated into liposomes before these intact liposomes were immobilized onto the surfaces of soft contact lenses using a multilayer immobilization strategy. The release of levofloxacin from contact lenses bearing 2, 5, and 10 layers of liposomes into a saline buffer at 37 degrees C was monitored by fluorescence. The levofloxacin release, as a function of time, was described by a mechanism taking into account two independent first-order kinetic models. The total release of levofloxacin from the contact lenses was completed within 6 days. The release of levofloxacin from contact lenses bearing 10 layers of liposomes and subsequently soaked overnight in a levofloxacin solution was also studied and compare to that of dried contact lenses without any chemical modification rehydrated in a levofloxacin solution. The antibacterial activity of the liposome-coated contact lenses against Staphylococcus aureus was evaluated by measuring (i) the diameters of the inhibition zone on an agar plate and (ii) the optical density using a broth assay. The liposome-coated lenses showed an antibacterial activity both on agar and in broth following 24 h. When initial bacteria inocula were equal or below 10(6) CFU/mL, all the bacteria were inhibited within 2 h. When using initial bacteria inocula of 10(8) CFU/mL, an initial burst release provided by soaking the liposomal lenses was required for the first hours to inhibit bacteria growth. (c) 2007 Wiley-Liss, Inc. and the American Pharmacists Association.
Li, Jinyang; Zhang, Xiahua; Zheng, Qinxiang; Zhu, Yirui; Wang, Hui; Ma, Huixiang; Jhanji, Vishal; Chen, Wei
2015-09-01
To comparatively evaluate the efficacy of a bandage contact lens (BCL) and autologous serum (AS) eye drops in the management of severe dry eye caused by Sjögren syndrome (SS). In this prospective randomized study, 40 patients with SS were enrolled. Patients were divided into 2 treatment groups: BCL and AS. A total of 37 patients were included, 18 patients (35 eyes) in the AS group and 19 patients (36 eyes) in the BCL group. At the end of 6 weeks, the best-corrected visual acuity improved significantly in the BCL group (0.5 ± 0.3 vs. 0.3 ± 0.2, P = 0.003) but not in the AS group (0.4 ± 0.3 vs. 0.3 ± 0.3, P = 0.11). The best-corrected visual acuity remained stable up to 6 weeks after discontinuation of the BCL (0.5 ± 0.3 vs. 0.4 ± 0.2, P = 0.03). Although the Ocular Surface Disease Index scores decreased significantly after treatment in both groups, patients in the BCL group had lower Ocular Surface Disease Index scores than those in the AS group (53.4 vs. 41.8 at week 3, 47.1 vs. 31.0 at week 6, 52.7 vs. 32.0 at week 12; P = 0.014, <0.001, <0.004, respectively). The "faces" scores showed improved quality of life in both groups. Tear break-up time improved significantly in both groups except at 6 weeks after discontinuation of the AS. Patients in the BCL group had lower corneal staining scores than those of the AS group after 6 weeks of treatment and 6 weeks after discontinuation of treatment (P < 0.01). There was no significant change in Schirmer I test scores between or within groups. Balafilcon A silicone hydrogel contact lenses as a BCL were effective in the management of SS-associated dry eye. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT02147509.
Spectral transmittance of UV-blocking soft contact lenses: a comparative study.
Rahmani, Saeed; Mohammadi Nia, Mohadeseh; Akbarzadeh Baghban, Alireza; Nazari, Mohammad Reza; Ghassemi-Broumand, Mohammad
2014-12-01
Three major parts of sunlight consist of visible, ultraviolet and infrared radiation. Exposure to ultraviolet radiation (UVR) can result in a spectrum of skin and ocular diseases. UV-blocking contact lenses help provide protection against harmful UV radiation. We studied the ultraviolet and visible light rays transmission in some soft UV-blocking contact lenses. Four available tinted soft lenses (Acuvue Moist, Zeiss CONTACT Day 30 Air spheric, Pretty Eyes and Sauflon 56 UV) have been evaluated for UV and visible transmission. One-way ANOVA testing was performed to establish is there a statistically significant difference between the UV regions and visible spectra means for the contact lenses (α=0.05). Pretty Eyes, Zeiss CONTACT, Acuvue Moist and Sauflon 56 UV showed UV-B transmittance value of 0.65%, 10.69%, 1.22%, and 5.78%, respectively. Pretty Eyes and Acuvue Moist had UV-A transmittance values of 32% and 34%, Sauflon 56 UV and Zeiss CONTACT had transmittance values of 48% and 43%, respectively. All of the studied lenses transmitted at least 94.6% on the visible spectrum. The results of the one-way ANOVA statistical analysis show that a statistically significant difference exists within the group of contact lenses tested for the visible (p<0.001), UV-B (p<0.001) and UV-A (p<0.001) portions of the spectrum (α=0.05). Acuvue Moist has the best UV-blocking property and also visible transmission between other tested contact lenses in this study. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Do swimming goggles limit microbial contamination of contact lenses?
Wu, Yvonne T; Tran, Jess; Truong, Michelle; Harmis, Najat; Zhu, Hua; Stapleton, Fiona
2011-04-01
Wearing goggles over contact lenses while swimming is often recommended by eye care professionals. Limited data are available to assess this recommendation. The purpose of this study was to examine whether wearing goggles while swimming limits bacterial colonization on contact lenses and whether the type of lens worn affects contamination rates. Twenty-three subjects underwent two swimming sessions at an ocean (salt water) pool (Maroubra beach Rock Pool, Sydney, Australia). Silicone hydrogel (Ciba Focus Night and Day) or hydrogel lenses (Ciba Focus Daily) were inserted into subjects' eyes before 30 min of swimming sessions, and subjects used modified goggles to mimic goggled and non-goggled conditions. At the end of each session, lenses were collected for microbial investigation. Viable bacterial colonies were classified as gram positive and gram negative and enumerated. The level of bacterial colonization on contact lenses between goggled and non-goggled conditions and between the two lens materials were compared. The range of colony forming units recovered from goggled lenses were 0 to 930 compared with 0 to 1210 on non-goggled lenses. The majority of subjects (16/23) had more microorganisms in the non-goggled condition than when wearing goggles (p = 0.03). Gram negative organisms were found in three non-goggled lenses. No significant difference was shown in the number of bacteria isolated from silicone hydrogel and hydrogel lenses (p > 0.6) irrespective of wearing goggles. Water samples had consistently higher numbers of bacterial counts than those adhered to the lenses; however, no association was found between the number of bacteria in the water sample and those found on the contact lenses. Consistently, fewer bacterial colonies were found on the goggled contact lens, thus suggesting goggles offer some protection against bacterial colonization of contact lenses while swimming. These data would support the recommendation encouraging lens wearers to use goggles while swimming.
... vision problems; this includes prescribing eyeglasses and contact lenses, but also doing eye surgery for other eye-related problems. An optometrist ... them clean. The most important thing about contact lenses is good hygiene to prevent infections in your eye. But the really fun part of new glasses ...
[Rules and regulations concerning contact lens-related infection].
Feys, J
2004-04-01
Contact lens-related infectious keratitis is a potentially sight-threatening complication. Bacterial keratitis, mostly due to Gram-negative bacteria, is associated with poor lens hygiene, overnight wear, and contaminated lens care solutions. Contamination of the lens storage case may cause fungal keratitis. Acanthamoeba infection is related to the use of tap water or swimming while wearing soft lenses. Viruses are of less concern among contact lens wearers. Possible transmission of Creutzfeldt-Jakob disease by multi-patient trial lenses must be taken in account. To minimize these risk factors, regulations are applied at various levels: CE marking of contact lenses and care products as they are medical devices; contact lens fitting only by health care professionals; distribution of contact lenses by opticians and lens care solutions by opticians and pharmacists; hygienic management of trial lenses following official recommendations. Contact lens-related keratitis must be reported to health care Authorities.
... if your eye(s) is/are red. If your eyes are not red and you wear contact lenses, you should know that alcaftadine solution contains benzalkonium chloride, which can be absorbed by soft contact lenses. Remove your contact lenses before instilling alcaftadine and put them back in 10 minutes later.
... if your eye(s) is/are red. If your eye is not red and you wear contact lenses, you should know that olopatadine solution contains benzalkonium chloride, which can be absorbed by soft contact lenses. Remove your contact lenses before applying olopatadine and put them back in 10 minutes later.
... if your eye(s) is/are red. If your eye is not red and you wear contact lenses, you should know that azelastine solution contains benzalkonium chloride, which can be absorbed by soft contact lenses. Remove your contact lenses before instilling azelastine and put them back in 10 minutes later.
... if your eye(s) is/are red. If your eyes are not red and you wear contact lenses, you should know that ketotifen solution contains benzalkonium chloride, which can be absorbed by soft contact lenses. Remove your contact lenses before instilling ketotifen and put them back in 10 minutes later.
The effect of protein-coated contact lenses on the adhesion and viability of gram negative bacteria.
Williams, Timothy J; Schneider, Rene P; Willcox, Mark D P
2003-10-01
Gram negative bacterial adhesion to contact lenses can cause adverse responses. During contact lens wear, components of the tear film adsorb to the contact lens. This study aimed to investigate the effect of this conditioning film on the viability of bacteria. Bacteria adhered to contact lenses which were either unworn, worn for daily-, extended- or overnight-wear or coated with lactoferrin or lysozyme. Numbers of viable and total cells were estimated. The number of viable attached cells was found to be significantly lower than the total number of cells on worn (50% for strain Paer1 on daily-wear lenses) or lactoferrin-coated lenses (56% for strain Paer1). Lysozyme-coated lenses no statistically significant effect on adhesion. The conditioning film gained through wear may not inhibit bacterial adhesion, but may act adversely upon those bacteria that succeed in attaching.
Special tinted contact lens on colour-defects.
Mutilab, H A; Sharanjeet-Kaur; Keu, L K; Choo, P F
2012-01-01
The objective of this study was to determine the visual function of colour-deficient subjects when wearing special red tint contact lenses. A total of 17 subjects with congenital colour vision deficiency (14 deutans and 3 protans), voluntarily participated in this study. The average age for the subjects was 23.00 ± 4.06 years old. Visual functions tested were visual acuity (LogMAR), contrast sensitivity (FACT Chart) and stereopsis (TNO and Howard Dolman tests). Two types of special red tint lenses were used in this study; Type I (light red) and Type II (dark red). The protans and deutans showed no significant changes in visual acuity and contrast sensitivity when wearing either type of contact lens. Stereopsis testing using the Horward-Dolman test gave no significant changes but significant differences were seen using the TNO test. Stereopsis using the TNO test was significantly poorer with the red tinted contact lenses compared to without for both protons and deutans. Testing binocularly with Ishihara plates showed that 88% (n=15) of patients passed the test with Type I and Type II contact lenses. When D15 test was done, 3 patients (17.6%) were 'normal' when using the Type I contact lenses and 2 patients (11.8%) were 'normal' when using the Type II contact lenses. However, with FM100Hue test, most patients showed deutan responses. Total error scores (TES) were found to be higher with Type I and Type II contact lenses compared to without. The Type I and II special tinted contact lens used in this study did not cause a reduction of visual acuity and contrast sensitivity for the colour defects. Stereopsis was also not reduced with the Type I and Type II contact lenses for the colour defects except when tested with the TNO test. Colour vision defects became difficult to detect using the Ishihara plates but FM100Hue test did not show any improvement with the Type I and Type II contact lenses.
Ocular discomfort responses after short periods of contact lens wear.
Papas, Eric; Tilia, Daniel; McNally, John; de la Jara, Percy Lazon
2015-06-01
To investigate if contact lens-related discomfort is a function of the time of day at which lenses are worn. This was a randomized, crossover, open-label clinical trial where subjective responses, with and without contact lenses, were assessed every 2 hours during five stages (A to E). Each stage began at the time when subjects would normally have inserted their contact lenses (T0). During stage A, no lenses were worn, whereas in stage B, lenses were worn continuously for 12 hours. In stages C to E, lenses were worn for only 4 hours. Contact lenses were inserted at T0 for stage C, but for stages D and E, lenses were not inserted until T0 + 4 and T0 + 8 hours, respectively. Mixed linear models were used for statistical analysis. In the absence of contact lenses, ocular comfort and dryness remained reasonably constant throughout the observation period. Ocular comfort and dryness decreased during 12 hours of continuous lens wear and became significantly worse from the 8-hour time onward compared with insertion (p < 0.023). There were no significant differences in terms of ocular comfort and dryness between any of the 4-hour lens wear stages (p < 0.82). During each 4-hour stage, both comfort and dryness behaved in a similar fashion (p > 0.05) to the first 4 hours of continuous contact lens wear. Comparing the scores of each of these stages with the no-lens response at the corresponding time showed no significant differences for comfort (p > 0.23) or dryness (p > 0.37). Short periods of wear can be experienced at any time of day without significant change in ocular discomfort and dryness. This suggests that subjective responses at the end of the day are determined by the length of time lenses are in contact with the eye, rather than the time of day at which lenses are worn.
Cole, Nerida; Hume, Emma B H; Vijay, Ajay K; Sankaridurg, Padmaja; Kumar, Naresh; Willcox, Mark D P
2010-01-01
One strategy to minimize bacteria-associated adverse responses such as microbial keratitis, contact lens-induced acute red eye (CLARE), and contact lens induced peripheral ulcers (CLPUs) that occur with contact lens wear is the development of an antimicrobial or antiadhesive contact lens. Cationic peptides represent a novel approach for the development of antimicrobial lenses. A novel cationic peptide, melimine, was covalently incorporated into silicone hydrogel lenses. Confirmation tests to determine the presence of peptide and anti-microbial activity were performed. Cationic lenses were then tested for their ability to prevent CLPU in the Staphylococcus aureus rabbit model and CLARE in the Pseudomonas aeruginosa guinea pig model. In the rabbit model of CLPU, melimine-coated lenses resulted in significant reductions in ocular symptom scores and in the extent of corneal infiltration (P < 0.05). Evaluation of the performance of melimine lenses in the CLARE model showed significant improvement in all ocular response parameters measured, including the percentage of eyes with corneal infiltrates, compared with those observed in the eyes fitted with the control lens (P < or = 0.05). Cationic coating of contact lenses with the peptide melimine may represent a novel method of prevention of bacterial growth on contact lenses and consequently result in reduction of the incidence and severity of adverse responses due to Gram-positive and -negative bacteria during lens wear.
Tear analysis in contact lens wearers.
Farris, R L
1985-01-01
Tear analysis in contact lens wearers was compared with tear analysis in aphakics without contact lens wear and normal phakic patients. Subjects were divided into five groups: group 1, aphakic without contact lens; group 2, phakic with daily-wear hard contact lens; group 3, phakic with daily-wear soft contact lens; group 4, phakic with extended-wear soft contact lens; and group 5, aphakic with extended-wear soft contact lens. The experimental groups were compared with age- and sex-matched control groups for statistical analysis of tear variables by means of the Student's t-test. The variables measured were tear osmolarity, tear albumin, and lysozyme and lactoferrin concentrations in basal and reflex tears. Highly significant elevations of tear osmolarity were found in aphakic subjects without contact lenses. Less significant differences in tear osmolarity were found in phakic subjects with hard daily-wear lenses or with extended-wear soft lenses. Tear albumin, lysozyme, and lactoferrin in basal and reflex tears were not significantly different in the different groups of contact lens wearers or in the group of aphakic subjects without contact lenses compared with their control groups. Individual variations in tear albumin, lysozyme, and lactoferrin appeared to be responsible for the inability to demonstrate significant differences in tear composition in association with the wearing of different types of contact lenses. Older and aphakic patients demonstrated a tendency to have increased concentrations of proteins in the tears compared with younger, phakic contact lens wearers and normal controls without contact lenses. PMID:3914131
Microbial adhesion to silicone hydrogel lenses: a review.
Willcox, Mark D P
2013-01-01
Microbial adhesion to contact lenses is believed to be one of the initiating events in the formation of many corneal infiltrative events, including microbial keratitis, that occur during contact lens wear. The advent of silicone hydrogel lenses has not reduced the incidence of these events. This may partly be related to the ability of microbes to adhere to these lenses. The aim of this study was to review the published literature on microbial adhesion to contact lenses, focusing on adhesion to silicone hydrogel lenses. The literature on microbial adhesion to contact lenses was searched, along with associated literature on adverse events that occur during contact lens wear. Particular reference was paid to the years 1995 through 2012 because this encompasses the time when the first clinical trials of silicone hydrogel lenses were reported, and their commercial availability and the publication of epidemiology studies on adverse events were studied. In vitro studies of bacterial adhesion to unworn silicone hydrogel lens have shown that generally, bacteria adhere to these lenses in greater numbers than to the hydroxyethyl methacrylate-based soft lenses. Lens wear has different effects on microbial adhesion, and this is dependent on the type of lens and microbial species/genera that is studied. Biofilms that can be formed on any lens type tend to protect the bacteria and fungi from the effects on disinfectants. Fungal hyphae can penetrate the surface of most types of lenses. Acanthamoeba adhere in greater numbers to first-generation silicone hydrogel lenses compared with the second-generation or hydroxyethyl methacrylate-based soft lenses. Microbial adhesion to silicone hydrogel lenses occurs and is associated with the production of corneal infiltrative events during lens wear.
Potential sources of bacteria that are isolated from contact lenses during wear.
Willcox, M D; Power, K N; Stapleton, F; Leitch, C; Harmis, N; Sweeney, D F
1997-12-01
The aim of this paper was to determine the possible contamination sources of contact lenses during wear. Potential sources of the microbiota that colonized hydrogel contact lenses during wear were examined. The microorganisms that colonize contact lenses were grown, identified, and compared to those microorganisms that colonized the lower lid margins, upper bulbar conjunctiva, hands, and contact lens cases of contact lens wearers. In addition, the incidence of contamination of the domestic water supply in the Sydney area was obtained, and this was compared to the incidence of colonization of contact lenses by microorganisms in general and gram-negative bacteria in particular. There was a wide diversity of bacteria that were isolated from each site sampled. Coagulase-negative staphylococci and Propionibacterium spp. were the most common isolates from all ocular sites examined, and constituted the normal ocular microbiota. Other bacteria, including members of the families Enterobacteriaceae and Pseudomonadaceae, were isolated infrequently from all sites, but most frequently from contact lens cases. Statistical analysis revealed that there was a correlation between the isolation of bacteria from the contact lens and the lower lid margin (p < 0.001). Analysis of this correlation revealed that this was true for the normal microbiota. A correlation was also noted between the colonization of contact lenses by gram-negative bacteria and contamination of the domestic water supply. This study has demonstrated that the likely route for the normal ocular microbiota colonizing contact lenses is via the lid margins, whereas colonization by gram-negative bacteria, including potential agents of microbial keratitis, is likely to be from the domestic water supply.
Fimbrolide-coated antimicrobial lenses: their in vitro and in vivo effects.
Zhu, Hua; Kumar, Ajay; Ozkan, Jerome; Bandara, Rani; Ding, Aidong; Perera, Indrani; Steinberg, Peter; Kumar, Naresh; Lao, William; Griesser, Stefani S; Britcher, Leanne; Griesser, Hans J; Willcox, Mark D P
2008-05-01
To examine the ability of contact lenses coated with fimbrolides, inhibitors of bacterial quorum sensing, to prevent microbial adhesion and their safety during short-term clinical assessment. A fimbrolide was covalently attached to commercially available high Dk contact lenses. Subsequently Pseudomonas aeruginosa, Staphylococcus aureus, Serratia marcescens, or Acanthamoeba sp. were added to the lenses and control uncoated contact lenses. Lenses plus microbes were incubated for 24 h, then washed thoroughly to remove non-adherent microbes. Lenses were macerated and resulting slurry plated onto agar plates. After appropriate incubation, the numbers of colony forming units of bacteria (or numbers of Acanthamoeba trophozoites measured using a hemocytometer) from fimbrolide-coated and uncoated lenses were examined. A Guinea Pig model of lens wear was used to assess the safety of lenses worn on a continuous basis for 1 month. In a separate study, 10 subjects wore fimbrolide-coated lenses for 24 h. The responses of the Guinea Pigs and human volunteers to the lenses were assessed by slit lamp examination. The fimbrolides-coated lenses reduced the adhesion of all bacterial strains tested, with reductions occurring of between 67 and 92%. For Acanthamoeba a reduction of 70% was seen. There were no significant differences in ocular responses to fimbrolide-coated lenses compared with controls in either the 1 month animal model or overnight human trial. Fimbrolide-coated lenses show promise as an antibacterial and anti-acanthamoebal coating on contact lenses and appear to be safe when worn on the eye in an animal model.
Maulvi, Furqan A; Lakdawala, Dhara H; Shaikh, Anjum A; Desai, Ankita R; Choksi, Harsh H; Vaidya, Rutvi J; Ranch, Ketan M; Koli, Akshay R; Vyas, Bhavin A; Shah, Dinesh O
2016-03-28
Glaucoma is commonly treated using eye drops, which is highly inefficient due to rapid clearance (low residence time) from ocular surface. Contact lenses are ideally suited for controlled drug delivery to cornea, but incorporation of any drug loaded particulate system (formulation) affect the optical and physical property of contact lenses. The objective of the present work was to implant timolol maleate (TM) loaded ethyl cellulose nanoparticle-laden ring in hydrogel contact lenses that could provide controlled drug delivery at therapeutic rates without compromising critical lens properties. TM-implant lenses were developed, by dispersing TM encapsulated ethyl cellulose nanoparticles in acrylate hydrogel (fabricated as ring implant) and implanted the same in hydrogel contact lenses (sandwich system). The TM-ethyl cellulose nanoparticles were prepared by double emulsion method at different ratios of TM to ethyl cellulose. The X-ray diffraction studies revealed the transformation of TM to amorphous state. In vitro release kinetic data showed sustained drug release within the therapeutic window for 168h (NP 1:3 batch) with 150μg loading. Cytotoxicity and ocular irritation study demonstrated the safety of TM-implant contact lenses. In vivo pharmacokinetic studies in rabbit tear fluid showed significant increase in mean residence time (MRT) and area under curve (AUC), with TM-implant contact lenses in comparison to eye drop therapy. In vivo pharmacodynamic data in rabbit model showed sustained reduction in intra ocular pressure for 192h. The study demonstrated the promising potential of implantation technology to treat glaucoma using contact lenses, and could serve as a platform for other ocular diseases. Copyright © 2016 Elsevier B.V. All rights reserved.
... Health and Consumer Devices Consumer Products Contact Lenses Contact Lens Risks Share Tweet Linkedin Pin it More ... redness blurred vision swelling pain Serious Hazards of Contact Lenses Symptoms of eye irritation can indicate a ...
Vermeltfoort, Pit B J; van der Mei, Henny C; Busscher, Henk J; Hooymans, Johanna M M; Bruinsma, Gerda M
2004-11-15
The aim of this study was to determine the transfer of Pseudomonas aeruginosa No. 3 and Staphylococcus aureus 835 from contact lenses to surfaces with different hydrophobicity and roughness. Bacteria were allowed to adhere to contact lenses (Surevue, PureVision, or Focus Night & Day) by incubating the lenses in a bacterial suspension for 30 min. The contaminated lenses were put on a glass, poly(methylmethacrylate), or silicone rubber substratum, shaped to mimic the eye. After 2 and 16 h, lenses were separated from the substrata and bacteria were swabbed off from the respective surfaces and resuspended in saline. Appropriate serial dilutions of these suspensions were made, from which aliquots were plated on agar for enumeration. Bacterial transfer varied between 4 and 60%, depending on the combination of strain, contact time, contact lens, and substratum surface. For P. aeruginosa No. 3, transfer was significantly higher after 16 h than after 2 h, whereas less increase with time was seen for S. aureus 835. Bacterial transfer from all tested contact lenses was least to silicone rubber, the most hydrophobic and roughest substratum surface included. (c) 2004 Wiley Periodicals, Inc.
Tear exchange and contact lenses: A review
Muntz, Alex; Subbaraman, Lakshman N.; Sorbara, Luigina; Jones, Lyndon
2015-01-01
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. PMID:25575892
Faghri, Jamshid
2008-05-01
Coagulase-negative staphylococci and diphtheroids are normal inhabitants of the outer surface of the human eye. These microorganisms serve as part of the defense mechanism of the ocular anatomy in preventing colonization and infection by pathogenic bacteria. Nevertheless, infections associated with contaminated solutions and cases became serious problems for people who wear soft contact lenses. The aim of this study is to isolate and identify aerobic bacteria, particularly, gram-negative species associated with the use of extended-wear soft contact lenses. Extended-wear contact lenses were collected, using aseptic technique, from the eyes of individuals after 30 days of extended wear (5-7 day intermittent periods) and were examined for adhered aerobic bacteria. Coagulase-negative staphylococci were isolated from 74% of the lenses. Serratia marcescens was found at an incidence of 10% and Pseudomonas aeruginosa at an incidence of 6%. The presence of species of bacteria, including P. aeruginosa and S. marcescens, which have been associated with daily wear soft contact lenses, solutions, and cases also seem to be associated with extended-wear lenses.
Management of complications associated with lathe-cut soft contact lenses.
Freeman, M I
1979-06-01
At the present time, nine lathe-cut lenses are FDA approved and commercially available in the United States. Complications of lathe-cut soft contact lenses cover a wide spectrum of problems. Five significant complications of lathe-cut lenses and their prevention and therapeutic management are discussed.
Zhao, Zhenjun; Fu, Han; Skotnitsky, Cheryl C; Sankaridurg, Padmaja R; Willcox, Mark D P
2008-03-01
To investigate whether the level of IgE is increased in the eyes of patients during general contact lens-induced papillary conjunctivitis (CLPC) events, which involve enlarged papillae across the entire palpebral conjunctiva, or local CLPC events, in which papillae are confined to one or two parts of the area. Worn contact lenses were collected and soaked in phosphate-buffered saline. The levels of eluted IgE and IgE retained on contact lenses were detected by enzyme-linked immunosorbent assay. IgE was detected in 6 of 12 cases of general CLPC, 8 of 21 cases of local CLPC, and none of 14 control contact lenses. The average level of eluted IgE was 0.54 +/- 1.06 IU/contact lens, 0.28 +/- 0.54 IU/contact lens, and 0.04 +/- 0.06 IU/contact lens for general CLPC, local CLPC, and the control group, respectively. The incidences of positive IgE were significantly higher in patients with CLPC (general and local) than in control subjects, but no statistical difference was found between general and local CLPC. Generally higher amounts of retained IgE were detected on contact lenses that had increased levels of eluted IgE. Contact lenses that were collected before or after a CLPC event did not show increased levels of IgE. The level of IgE is increased in the eyes of some patients during an acute event of CLPC. The similar incidence of IgE-positive cases and levels of IgE from general and local CLPC contact lenses suggest that the conditions may share similar causal pathways.
Direct Laser Writing of Nanophotonic Structures on Contact Lenses.
AlQattan, Bader; Yetisen, Ali K; Butt, Haider
2018-04-24
Contact lenses are ubiquitous biomedical devices used for vision correction and cosmetic purposes. Their application as quantitative analytical devices is highly promising for point-of-care diagnostics. However, it is a challenge to integrate nanoscale features into commercial contact lenses for application in low-cost biosensors. A neodymium-doped yttrium aluminum garnet (Nd:YAG) laser (1064 nm, 3 ns pulse, 240 mJ) in holographic interference patterning mode was utilized to produce optical nanostructures over the surface of a hydrogel contact lens. One-dimensional (925 nm) and two-dimensional (925 nm × 925 nm) nanostructures were produced on contact lenses and analyzed by spectroscopy and angle-resolve measurements. The holographic properties of these nanostructures were tested in ambient moisture, fully hydrated, and artificial tear conditions. The measurements showed a rapid tuning of optical diffraction from these nanostructures from 41 to 48°. The nanostructures were patterned near the edges of the contact lens to avoid any interference and obstruction to the human vision. The formation of 2D nanostructures on lenses increased the diffraction efficiency by more than 10%. The versatility of the holographic laser ablation method was demonstrated by producing four different 2D nanopattern geometries on contact lenses. Hydrophobicity of the contact lens was characterized by contact angle measurements, which increased from 59.0° at pristine condition to 62.5° at post-nanofabrication. The holographic nanostructures on the contact lens were used to sense the concentration of Na + ions. Artificial tear solution was used to simulate the conditions in dry eye syndrome, and nanostructures on the contact lenses were used to detect the electrolyte concentration changes (±47 mmol L -1 ). Nanopatterns on a contact lens may be used to sense other ocular diseases in early stages at point-of-care settings.
Lunardi, Letícia Helena; Arroyo, Danielle; Andrade Sobrinho, Marcelo Vicente de; Lipener, César; Rosa, Juliana Maria da Silva
2016-04-01
Keratoconus is characterized by bilateral asymmetrical corneal ectasia that leads to inferior stromal thinning and corneal protrusion. There is currently a lack of consensus regarding the most efficacious method for fitting contact lenses in patients with keratoconus, given the various topographical patterns and evolution grades observed in affected populations. The purpose of the present study was to evaluate the association between keratoconus evolution grade and topography pattern and the type and design of fitted contact lens. We performed a retrospective analysis of contact lenses fitted in a total of 185 patients with keratoconus (325 eyes). Keratoconus was classified as either grade I, II, III, or IV based on keratometry and cone morphology (nipple, oval, globus, or indeterminate) results. A total of 325 eyes were evaluated in the present study. Of the 62 eyes classified as grade I, 66.1% were fitted with monocurve contact lenses. Of the 162 eyes classified as grade I and II, 51%, 30%, and 19% were fitted with adapted monocurve rigid gas-permeable contact lenses (RGPCL), bicurve lenses, and others lens types, respectively. Bicurve lenses were fitted in 52.1% and 62.2% of eyes classified as grade III and IV, respectively. Of the eyes classified as grade III and IV, monocurve and bicurve RGPCL were fitted in 26% and 55%, respectively. In eyes with oval keratoconus, 45%, 35%, and 20% were fitted with monocurve lenses, bicurve lenses, and other lens types, respectively. In eyes with round cones (nipple morphology), 55%, 30%, and 15% were fitted with bicurve lenses, monocurve lenses, and other lens types, respectively. Monocurve RGPCL were most frequently fitted in patients with mild to moderate keratoconus and oval cones morphology, while bicurve lenses were more frequently fitted in patients with severe and advanced keratoconus. This was probably because bicurve lenses are more appropriate for round cones due to increased corneal asphericity.
A Prototype Antifungal Contact Lens
Ciolino, Joseph B.; Hudson, Sarah P.; Mobbs, Ashley N.; Hoare, Todd R.; Iwata, Naomi G.; Fink, Gerald R.
2011-01-01
Purpose. To design a contact lens to treat and prevent fungal ocular infections. Methods. Curved contact lenses were created by encapsulating econazole-impregnated poly(lactic-co-glycolic) acid (PLGA) films in poly(hydroxyethyl methacrylate) (pHEMA) by ultraviolet photopolymerization. Release studies were conducted in phosphate-buffered saline at 37°C with continuous shaking. The contact lenses and their release media were tested in an antifungal assay against Candida albicans. Cross sections of the pre- and postrelease contact lenses were characterized by scanning electron microscopy and by Raman spectroscopy. Results. Econazole-eluting contact lenses provided extended antifungal activity against Candida albicans fungi. Fungicidal activity varied in duration and effectiveness depending on the mass of the econazole-PLGA film encapsulated in the contact lens. Conclusions. An econazole-eluting contact lens could be used as a treatment for fungal ocular infections. PMID:21527380
Staph infections - self-care at home
... soap and water. Or use an alcohol-based hand sanitizer. Keep cuts and scrapes clean and covered with bandages until they heal. Avoid contact with other people's wounds ... your hands well before and after playing sports. Shower right ...
Fitting an MSD (mini scleral design) rigid contact lens in advanced keratoconus with INTACS.
Dalton, Kristine; Sorbara, Luigina
2011-12-01
Keratoconus is a bilateral degenerative disease characterized by a non-inflammatory, progressive central corneal ectasia (typically asymmetric) and decreased vision. In its early stages it may be managed with spectacles and soft contact lenses but more commonly it is managed with rigid contact lenses. In advanced stages, when contact lenses can no longer be fit, have become intolerable, or corneal damage is severe, a penetrating keratoplasty is commonly performed. Alternative surgical techniques, such as the use of intra-stromal corneal ring segments (INTACS) have been developed to try and improve the fit of rigid contact lenses in keratoconic patients and avoid penetrating keratoplasties. This case report follows through the fitting of rigid contact lenses in an advanced keratoconic cornea after an INTACS procedure and discusses clinical findings, treatment options, and the use of mini-scleral and scleral lens designs as they relate to the challenges encountered in managing such a patient. Mini-scleral and scleral lenses are relatively easy to fit, and can be of benefit to many patients, including advanced keratoconic patients, post-INTAC patients and post-penetrating keratoplasty patients. 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Desai, Ankita R; Maulvi, Furqan A; Pandya, Mihir M; Ranch, Ketan M; Vyas, Bhavin A; Shah, Shailesh A; Shah, Dinesh O
2018-05-29
Glaucoma is a chronic disease, which is currently treated using frequent high dose applications of an eye drop solution; this method is tedious, and most of patients are non-compliant to it. Contact lenses are emerging as a convenient option to sustain the release of ophthalmic drugs. However, the incorporation of a drug/formulation changes the optical and physical properties of contact lenses. Contact lens users have also reported pink eye syndrome; this makes contact lenses unsuitable to be accepted as a medical device. The objective of the present study was to design novel timolol and hyaluronic acid (comfort agent)-loaded semi-circular ring-implanted contact lenses that could uphold the release at therapeutic rates without compromising the critical lens properties. The drug-loaded rings were individually implanted within the periphery of the contact lenses using modified cast-moulding technology. Atomic force microscopy showed an average roughness of 12.38 nm for the implanted lens that was significantly lower as compared to that of the Freshlook contact lenses (116.27 nm). A major amount of timolol was leached (from 46.47 to 58.79%) during the monomer extraction and moist sterilization (autoclave) steps; therefore, the lenses were sterilized by radiation and packaged under dry conditions (dehydrated). The in vitro release data showed sustained release of timolol and hyaluronic acid up to 96 h. The in vivo drug release study on rabbit eyes showed the presence of timolol in tear fluid up to 72 h. The in vivo pharmacodynamics studies showed a reduction in IOP till 144 h with a low drug loading (154 μg) as compared to the case of a single instillation eye drop solution (250 μg). This study has demonstrated the successful application of implantation technology to co-deliver timolol and hyaluronic acid from contact lenses for an extended period of time to treat glaucoma.
Draeger, J; Schröder, U; Vogt, L
1980-03-01
It is still forbidden by German law for cockpit aircrew to wear contact lenses. This is due in particular to experience gathered in the past with older types of contact lenses, especially those made of glass or PMMA. Meanwhile, technological progress has brought improvements in respect of material, size, tolerance and particularly the optical result. Investigations were carried out with regard to the tolerance of contact lenses in condition of low humidity, high g and sudden compression. The results are given and the consequences for cockpit aircrew and passengers are discussed.
Biological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses
Omali, Negar Babaei; Subbaraman, Lakshman N.; Coles-Brennan, Chantal; Fadli, Zohra; Jones, Lyndon W.
2015-01-01
ABSTRACT Within a few minutes of wear, contact lenses become rapidly coated with a variety of tear film components, including proteins, lipids, and mucins. Tears have a rich and complex composition, allowing a wide range of interactions and competitive processes, with the first event observed at the interface between a contact lens and tear fluid being protein adsorption. Protein adsorption on hydrogel contact lenses is a complex process involving a variety of factors relating to both the protein in question and the lens material. Among tear proteins, lysozyme is a major protein that has both antibacterial and anti-inflammatory functions. Contact lens materials that have high ionicity and high water content have an increased affinity to accumulate lysozyme during wear, when compared with other soft lens materials, notably silicone hydrogel lenses. This review provides an overview of tear film proteins, with a specific focus on lysozyme, and examines various factors that influence protein deposition on contact lenses. In addition, the impact of lysozyme deposition on various ocular physiological responses and bacterial adhesion to lenses and the interaction of lysozyme with other tear proteins are reviewed. This comprehensive review suggests that deposition of lysozyme on contact lens materials may provide a number of beneficial effects during contact lens wear. PMID:26002002
An evaluation of 1-day disposable contact lens wear in a population of allergy sufferers.
Hayes, Valérie Y; Schnider, Cristina M; Veys, Jane
2003-06-01
This was a multi-site, 128-subject, bilateral crossover study to evaluate subjective comfort and slit-lamp findings with 1-day disposable contact lenses in a population of allergy sufferers during periods when allergen levels were elevated. The study involved 1-month of single-use daily wear with a 1-day disposable test lens (1. DAY ACUVUE Brand Contact Lenses, Johnson & Johnson Vision Care) and 1-month of daily wear with subjects' habitual lenses replaced to their usual replacement schedule. Pollen and mould counts were obtained for each site 1 week prior to the study and twice weekly throughout the study period. Subjective comfort and slit-lamp findings were recorded at baseline and after 1-month's wear of each modality. Sixty-seven percent of subjects agreed that the 1-day disposable lenses provided improved comfort when compared to the lenses they wore prior to the study, compared with 18% agreeing that the new pair of habitual lenses provided improved comfort. The 1-day disposable lenses showed greater improvement in slit-lamp findings from baseline than new habitual lenses. The use of 1-day disposable lenses is an effective strategy for managing allergy-suffering contact lens wearers.
Non-invasive monitoring of skin inflammation using an oxygen-sensing paint-on bandage
Li, Zongxi; Navarro-Alvarez, Nalu; Keeley, Emily J.; Nowell, Nicholas H.; Goncalves, Beatriz M. M.; Huang, Christene A.; Evans, Conor L.
2017-01-01
Inflammation involves a cascade of cellular and molecular mediators that ultimately lead to the infiltration of immune cells into the affected area. This inflammatory process in skin is common to many diseases including acne, infection, and psoriasis, with the presence or absence of immune cells a potential diagnostic marker. Here we show that skin inflammation can be non-invasively measured and mapped using a paint-on oxygen sensing bandage in an in vivo porcine inflammation model. After injection of a known inflammatory agent, the bandage could track the increase, plateau, and decrease in oxygen consumption at the injury site over 7 weeks, as well as discern inflammation resultant from injection at various depths beneath the surface of the skin. Both the initial rate of pO2 change and the change in bandage pO2 at equilibration (CBP20) were found to be directly related to the metabolic oxygen consumption rate of the tissue in contact. Healthy skin demonstrated an initial pO2 decrease rate of 6.5 mmHg⋅min−1, and CBP20 of 84 mmHg. Inflamed skin had a significantly higher initial consumption rate of 55 mmHg⋅min−1, and a larger CBP20 of 140 mmHg. The change in the bandage pO2 before and after equilibration with tissue was found to correlate well with histological evidence of skin inflammation in the animals. PMID:29082091
Papadatou, Eleni; Del Águila-Carrasco, Antonio J; Esteve-Taboada, José J; Madrid-Costa, David; Cerviño-Expósito, Alejandro
2017-01-01
To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses. Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed. The power distribution of the lenses was affected by pupil size differently. One of the lenses showed a significant spread in refractive power distribution, from about -3 D to 0 D. Generally, the power distribution of the lenses expanded as the pupil diameter became greater. The surface of the lens dedicated for each distance varied substantially with the design of the lens. In an experimental basis, our results show how the lenses power distribution is affected by the pupil size and underlined the necessity of careful evaluation of the patient's visual needs and the optical properties of a multifocal contact lens for achieving the optimal visual outcome.
Biocompatibility of antimicrobial melimine lenses: rabbit and human studies.
Dutta, Debarun; Ozkan, Jerome; Willcox, Mark D P
2014-05-01
Covalent immobilization of antimicrobial peptide melimine onto contact lenses can produce broad-spectrum antimicrobial lenses. The purpose of this study was to investigate the performance of melimine-coated contact lenses in an animal model and human clinical trial. Melimine was covalently attached onto the surface of contact lenses via EDC (1-ethyl-3-[3-dimethylaminopropyl] carbodiimide hydrochloride) coupling. A rabbit model of daily contralateral wear of lenses for 22 days was conducted to assess the lens safety. A prospective, randomized, double-masked, one-day human clinical trial was used to evaluate subjective responses and ocular physiology during contralateral wear of melimine-coated (test) and uncoated (control) lenses. Delayed reactions were monitored during follow-up visits after 1 and 4 weeks. Ex vivo retention of antimicrobial activity of worn lenses was assessed by reduction in numbers of viable Pseudomonas aeruginosa and Staphylococcus aureus. Melimine-coated lenses produced no ocular signs or symptoms that would indicate cytotoxicity during the lens wear of rabbits. No histological changes were found in rabbit corneas. During the human trial, no differences were observed in wettability, surface deposition, lens-fitting centration, movement, tightness, and corneal coverage between test and control lenses (p > 0.05). There were no significant differences in bulbar, limbal, or palpebral redness or conjunctival staining (p > 0.05). Mean corneal (extent, depth, and type) staining was higher for test lenses compared with that for control lenses (p < 0.05). There was no significant difference in subjective responses for lens comfort, dryness, and awareness (p > 0.05). No delayed reactions were associated with the test lenses. Worn test lenses retained more than 1.5 log inhibition against both bacterial types. Melimine-coated contact lenses were worn safely by humans. However, they were associated with higher corneal staining. The melimine-coated lenses retained high antibacterial activity after wear.
Bauer, Irmgard L
2015-01-01
Safe contact lens wear depends on a hygiene regime and lens-appropriate wear patterns which may be compromised during travel in remote and wilderness areas. The purpose of this study was to describe the experience of contact lens wearers while trekking at high-altitude in Nepal. For this descriptive study, trekkers with contact lenses were recruited in Lukla and invited to complete an online-questionnaire on trip preparation, contact lens use, care and experiences, and possible changes for future travel. Quantitative data were analysed using SurveyMonkey; content analysis applied to qualitative responses. The majority of the 158 participants (124; 78.48%) reported no problems with their lenses (daily disposables, soft lenses, extended-wear lenses, hard/rigid lenses) during their stay although dry air, dust, wind, cold temperatures, and difficult hygiene maintenance were challenging. Freezing lenses and freezing solutions were additional challenges. Thirty-four (21.52%) experienced a variety of problems. Improvements were requested from manufacturers. Lodges should provide better access to clean water, mirrors and lighting. Almost 60% of participants had not sought any pre-travel health advice. Remote and wilderness areas provide a challenge for appropriate contact lens wear and care. The decision between the potential risk of infection due to touching lenses (daily disposables, soft/hard lenses) and the potential risk of corneal erosion (extended-wear lenses) needs to be made in pre-travel consultations. Travel health professionals and travel agencies should remind CL-wearing trekkers to carefully assess their wear and care routine to accommodate potentially challenging conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.
Fungal keratitis and contact lenses: an old enemy unrecognized or a new nemesis on the block?
Tuli, Sonal S; Iyer, Sandhya A; Driebe, William T
2007-11-01
To review studies of fungal keratitis related to contact lenses and determine whether the recent insurgence is a new phenomenon or an exacerbation of an ongoing trend. A review of the recent literature on contact lens-related fungal ulcers and a comparison to older studies. The incidence of fungal keratitis associated with contact lenses increased from 5% in the 1980s to between 10% and 25% in the 1990s and was noted to be 44% in Florida at the turn of the century. The most recent study from Florida showed that the incidence had increased from 29% in the late 1990s to 52% in the early 2000s, even before the Fusarium keratitis epidemic in 2004 and 2005. This increase mainly represented an increase in the number related to nontherapeutic contact lenses. Contact lens-related fungal keratitis was relatively rare 20 years ago. However, the incidence has progressively increased since then. Contact lens-related fungal ulcers had become more common even before the recent Fusarium keratitis epidemic. This change may be related to changing contact lens care habits and younger patients being fitted with contact lenses.
Power profiles of single vision and multifocal soft contact lenses.
Wagner, Sandra; Conrad, Fabian; Bakaraju, Ravi C; Fedtke, Cathleen; Ehrmann, Klaus; Holden, Brien A
2015-02-01
The purpose of this study was to investigate the optical zone power profile of the most commonly prescribed soft contact lenses to assess their potential impact on peripheral refractive error and hence myopia progression. The optical power profiles of six single vision and ten multifocal contact lenses of five manufacturers in the powers -1.00 D, -3.00 D, and -6.00 D were measured using the SHSOphthalmic (Optocraft GmbH, Erlangen, Germany). Instrument repeatability was also investigated. Instrument repeatability was dependent on the distance from the optical centre, manifesting unreliable data for the central 1mm of the optic zone. Single vision contact lens measurements of -6.00 D lenses revealed omafilcon A having the most negative spherical aberration, lotrafilcon A having the least. Somofilcon A had the highest minus power and lotrafilcon A the biggest deviation in positive direction, relative to their respective labelled powers. Negative spherical aberration occurred for almost all of the multifocal contact lenses, including the centre-distance designs etafilcon A bifocal and omafilcon A multifocal. Lotrafilcon B and balafilcon A seem to rely predominantly on the spherical aberration component to provide multifocality. Power profiles of single vision soft contact lenses varied greatly, many having a negative spherical aberration profile that would exacerbate myopia. Some lens types and powers are affected by large intra-batch variability or power offsets of more than 0.25 dioptres. Evaluation of power profiles of multifocal lenses was derived that provides helpful information for prescribing lenses for presbyopes and progressing myopes. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Candida albicans and Pseudomonas aeruginosa adhesion on soft contact lenses.
Onurdağ, Fatma Kaynak; Ozkan, Semiha; Ozgen, Selda; Olmuş, Hülya; Abbasoğlu, Ufuk
2011-04-01
In this study it was aimed to determine the adherence of Pseudomonas and Candida to contact lens surfaces, and to determine the difference in adherence between five contact lens types. Biofilm-negative control strains were also used to emphasize the difference between biofilm-positive and biofilm-negative strains in adherence. Five different soft contact lenses were used to investigate the adherence of Pseudomonas aeruginosa and Candida albicans strains. P. aeruginosa ATCC 27853, P. aeruginosa ATCC 10145, C.albicans ATCC 10231 standard strains and C. albicans clinical isolate were included in the study. Slime formation was investigated by two methods; modified Christensen macrotube method, and a modified microtiter plate test. P. aeruginosa and C. albicans slime formation on soft contact lenses was studied in adherence and separation phases. Pseudomonas and Candida suspensions were serially diluted and inoculated to blood agar and sabouraud dextrose agar surfaces respectively. After overnight incubation, the colonies were counted. Sterile unworn contact lenses were used as negative controls, and bacterial and fungal culture suspensions were used as positive controls. The experiments were conducted in three parallel series. The number of adherent Pseudomonas was as follows from high to low in polymacon, etafilcon A, hilafilcon, ocufilcon and lotrafilcon contact lenses respectively. However, the number of adherent yeast were determined higher in lotrafilcon and ocufilcon contact lenses, followed by hilafilcon, etafilcon A and polymacon contact lenses. Biofilm-negative Pseudomonas ATCC standard strain and Candida clinical isolate were used to confirm that the number of adherent cells were lower than the biofilm-positive ones. This study demonstrates that in addition to the contact lens properties, the microorganisms themselves and their interactions with the lens material also play an important role in adherence.
Sarac, Ozge; Gurdal, Canan; Bostancı-Ceran, Basak; Can, Izzet
2012-06-01
The aim of this study was to evaluate tear osmolarity and ocular comfort with two different types of hydrogel daily disposable lenses. The right eyes of 15 first-time contact lens users were included in this prospective study. All eyes wore hilafilcon B silicone hydrogel contact lenses for 8 h (group 1). After 1 week without contact lenses, all eyes wore narafilcon A silicone hydrogel contact lenses for 8 h (group 2). Tear osmolarity measurement was performed before and after 4 and 8 h of each contact lens wear. Ocular comfort was assessed after 4 and 8 h of each contact lens wear. In group 1, the mean baseline, 4- and 8-h tear osmolarity values were 293 ± 10.57, 303.00 ± 10.5 mOsm/L (p = 0.023), and 295.0 ± 1.4 mOsm/L (p > 0.05), respectively. In group 2, the mean baseline, 4- and 8-h tear osmolarity values were 294 ± 13.65, 300.9 ± 11.3 mOsm/L (p = 0.007), and 298.80 ± 7.2 mOsm/L (p > 0.05), respectively. In group 1, the mean comfort score was 7.20 ± 0.45 and 8.60 ± 0.45 at 4 and 8 h, respectively (p = 0.038). In group 2, the mean comfort score significantly decreased from 9.80 ± 0.45 to 7.80 ± 0.84 at 4 h (p = 0.039). Both hydrogel and silicone hydrogel daily disposable contact lenses elevated tear osmolarity during 8 h of contact lens wear. The increase in tear osmolarity with both contact lenses was below the cut-off value for dry eye and was not associated with ocular comfort.
Lin, David Pei-Cheng; Chang, Han-Hsin; Yang, Li-Chien; Huang, Tzu-Ping; Liu, Hsiang-Jui; Chang, Lin-Song; Lin, Chien-Hsun
2013-01-01
Purpose Weekly disposable soft contact lenses have been widely used recently, but their shield effects against ultraviolet (UV) irradiation remain to be evaluated. This study investigated the bioprotective effects of several weekly soft contact lenses against UVB irradiation on the corneal surface in a mouse model. Methods Fifty ICR mice were randomly divided into five groups: (1) blank control, (2) exposed to UVB without contact lens protection, (3) exposed to UVB and protected with Vifilcon A contact lenses, (4) exposed to UVB and protected with Etafilcon A contact lenses, and (5) exposed to UVB and protected with HEMA+MA contact lenses. The exposure to UVB irradiation was performed at 0.72 J/cm2/day after anesthesia for a 7-day period, followed by cornea surface assessment for smoothness, opacity, and grading of lissamine green staining. Tissue sections were prepared for hematoxylin and eosin staining and immunohistochemical detection by using antibodies against myeloperoxidase, cytokeratin-5, P63, Ki-67, nuclear factor-kappa B (p65), cyclooxygenase-2, Fas L, and Fas. Results The results showed impaired corneal surface with myeloperoxidase+ polymorphonuclear leukocyte infiltration into the stroma after UVB exposure, in contrast to the intact status of the blank controls. The corneas with Etafilcon A and HEMA+MA contact lenses maintained more cells positive for cytokeratin-5, P63, and Ki-67 compared to those with Vifilcon A or without contact lens protection. Furthermore, less proinflammatory factors, including nuclear factor-kappa (p65), cyclooxygenase-2, Fas L, and Fas, were induced in the corneas protected by Etafilcon A and HEMA+MA. Conclusions This study demonstrated various protective effects of weekly disposable contact lenses against UVB irradiation. The mouse model used in the present study may be used extensively for in vivo assessment of UV shield efficacy. PMID:23734085
Factors influencing bacterial adhesion to contact lenses.
Dutta, Debarun; Cole, Nerida; Willcox, Mark
2012-01-01
The process of any contact lens related keratitis generally starts with the adhesion of opportunistic pathogens to contact lens surface. This article focuses on identifying the factors which have been reported to affect bacterial adhesion to contact lenses. Adhesion to lenses differs between various genera/species/strains of bacteria. Pseudomonas aeruginosa, which is the predominant causative organism, adheres in the highest numbers to both hydrogel and silicone hydrogel lenses in vitro. The adhesion of this strain reaches maximum numbers within 1h in most in vitro studies and a biofilm has generally formed within 24 h of cells adhering to the lens surface. Physical and chemical properties of contact lens material affect bacterial adhesion. The water content of hydroxyethylmethacrylate (HEMA)-based lenses and their iconicity affect the ability of bacteria to adhere. The higher hydrophobicity of silicone hydrogel lenses compared to HEMA-based lenses has been implicated in the higher numbers of bacteria that can adhere to their surfaces. Lens wear has different effects on bacterial adhesion, partly due to differences between wearers, responses of bacterial strains and the ability of certain tear film proteins when bound to a lens surface to kill certain types of bacteria.
Factors influencing bacterial adhesion to contact lenses
Dutta, Debarun; Willcox, Mark
2012-01-01
The process of any contact lens related keratitis generally starts with the adhesion of opportunistic pathogens to contact lens surface. This article focuses on identifying the factors which have been reported to affect bacterial adhesion to contact lenses. Adhesion to lenses differs between various genera/species/strains of bacteria. Pseudomonas aeruginosa, which is the predominant causative organism, adheres in the highest numbers to both hydrogel and silicone hydrogel lenses in vitro. The adhesion of this strain reaches maximum numbers within 1h in most in vitro studies and a biofilm has generally formed within 24 h of cells adhering to the lens surface. Physical and chemical properties of contact lens material affect bacterial adhesion. The water content of hydroxyethylmethacrylate (HEMA)-based lenses and their iconicity affect the ability of bacteria to adhere. The higher hydrophobicity of silicone hydrogel lenses compared to HEMA-based lenses has been implicated in the higher numbers of bacteria that can adhere to their surfaces. Lens wear has different effects on bacterial adhesion, partly due to differences between wearers, responses of bacterial strains and the ability of certain tear film proteins when bound to a lens surface to kill certain types of bacteria. PMID:22259220
Novel Approaches in Formulation and Drug Delivery using Contact Lenses
Singh, Kishan; Nair, Anroop B; Kumar, Ashok; Kumria, Rachna
2011-01-01
The success of ocular delivery relies on the potential to enhance the drug bioavailability by controlled and extended release of drug on the eye surface. Several new approaches have been attempted to augment the competence and diminish the intrinsic side effects of existing ocular drug delivery systems. In this contest, progress has been made to develop drug-eluting contact lens using different techniques, which have the potential to control and sustain the delivery of drug. Further, the availability of novel polymers have facilitated and promoted the utility of contact lenses in ocular drug delivery. Several research groups have already explored the feasibility and potential of contact lens using conventional drugs for the treatment of periocular and intraocular diseases. Contact lenses formulated using modern technology exhibits high loading, controlled drug release, apposite thickness, water content, superior mechanical and optical properties as compared to commercial lenses. In general, this review discus various factors and approaches designed and explored for the successful delivery of ophthalmic drugs using contact lenses as drug delivery device PMID:24826007
Tear exchange and contact lenses: a review.
Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon
2015-01-01
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
In vivo performance of a drug-eluting contact lens to treat glaucoma for a month
Ciolino, Joseph B.; Stefanescu, Cristina F.; Ross, Amy E.; Salvador-Culla, Borja; Cortez, Priscila; Ford, Eden M.; Wymbs, Kate A.; Sprague, Sarah L.; Mascoop, Daniel R.; Rudina, Shireen S.; Trauger, Sunia A.; Cade, Fabiano; Kohane, Daniel S.
2013-01-01
For nearly half a century, contact lenses have been proposed as a means of ocular drug delivery, but achieving controlled drug release has been a significant challenge. We have developed a drug-eluting contact lens designed for prolonged delivery of latanoprost for the treatment of glaucoma, the leading cause of irreversible blindness worldwide. Latanoprost-eluting contact lenses were created by encapsulating latanoprost–poly(lactic-co-glycolic acid) films in methafilcon by ultraviolet light polymerization. In vitro and in vivo studies showed an early burst of drug release followed by sustained release for one month. Contact lenses containing thicker drug–polymer films demonstrated released a greater amount of drug after the initial burst. In vivo, single contact lenses were able to achieve, for at least one month, latanoprost concentrations in the aqueous humor that were comparable to those achieved with topical latanoprost solution, the current first-line treatment for glaucoma. The lenses appeared safe in cell culture and animal studies. This contact lens design can potentially be used as a treatment for glaucoma and as a platform for other ocular drug delivery applications. PMID:24094935
[Some special indications for wearing contact lenses (author's transl)].
Müller, K
1978-12-01
The typical distinguishing features of special cases which require contact lenses for satisfactory vision are described. Hence in the first case with anisometria associated with irregular astigmatism of one eye, to which a toric soft contact lens was adapted. In the second case a visual acuity of only 0,6 monocular was attained with the best spectacle lens, however with contact lense the visual acuity was 1.25. Here a verdict from a social court is mentioned, which obliged the sickness insurance to take over the costs for such a case. In the third case the adaptation of contact lenses was undertaken after radical bilateral keratoplasty because of parenchymatous keratitis, and an improvement in visual acuity of at least 400% resulted.
Salicylate inhibition of acanthamoebal attachment to contact lenses.
Beattie, Tara K; Tomlinson, Alan; Seal, David V; McFadyen, Angus K
2011-12-01
Sodium salicylate has shown potential as a component of contact lens care solutions designed to reduce Acanthamoebal attachment to contact lenses. This study determined the minimum effective concentration required to significantly reduce amoebal attachment. Different concentrations of sodium salicylate (10, 15, and 20 mM) were applied during exposure of unworn or bacterial biofilm-coated hydrogel contact lenses to Acanthamoeba castellanii trophozoites. Salicylate was applied at stage 1 intervention during biofilm formation on lenses, at stage 2 intervention during amoebal exposure, or at both stages. A significant reduction in amoebal attachment was achieved when 10 mM salicylate was included during stage 1 alone; however, 15 mM was required for stage 2 intervention to significantly reduce attachment to clean or biofilm-coated lenses. For stages 1 and 2 combined intervention, 10 mM sodium salicylate produced a significant reduction in amoebal attachment. In situ, within a contact lens case, biofilm formation and amoebal attachment would occur concurrently; therefore, stages 1 and 2 intervention would be closest to the real-life situation, thus indicating that 10 mM of salicylate would be an effective minimum concentration for reducing amoebal attachment to hydrogel contact lenses. Inclusion of components in contact lens care solution, such as sodium salicylate, which reduce Acanthamoebal attachment, has the potential to enhance effectiveness, particularly where amoebicidal efficacy may be limited, thus reducing the risk of contact lens-associated Acanthamoebal infection.
Corneal erosions, bacterial contamination of contact lenses, and microbial keratitis.
Willcox, Mark D P; Naduvilath, Thomas J; Vaddavalli, Pravin K; Holden, Brien A; Ozkan, Jerome; Zhu, Hua
2010-11-01
To estimate the rate of corneal erosion coupled with gram-negative bacterial contamination of contact lenses and compare this with the rate of microbial keratitis (MK) with contact lenses. The rate of corneal erosion and contact lens contamination by gram-negative bacteria were calculated from several prospective trials. These rates were used to calculate the theoretical rate of corneal erosion happening at the same time as wearing a contact lens contaminated with gram-negative bacteria. This theoretical rate was then compared with the rates of MK reported in various epidemiological and clinical trials. Corneal erosions were more frequent during extended wear (0.6-2.6% of visits) compared with daily wear (0.01-0.05% of visits). No corneal erosions were observed for lenses worn on a daily disposable basis. Contamination rates for lenses worn on a daily disposable basis were the lowest (2.4%), whereas they were the highest for low Dk lenses worn on an extended wear basis (7.1%). The estimated rate of corneal erosions occurring at the same time as wearing lenses contaminated with gram-negative bacteria was the lowest during daily wear of low Dk lenses (1.56/10,000 [95% CI: 0.23-10.57]) and the highest during extended wear of high Dk lenses (38.55/10,000 [95% CI: 24.77-60.04]). These rates were similar in magnitude to the rates reported for MK of different hydrogel lenses worn on differing wear schedules. The coincidence of corneal erosions during lens wear with gram-negative bacterial contamination of lenses may account for the relative incidence of MK during lens wear with different lens materials and modes of use.
Das, T; Sharma, S; Singh, J; Rao, V; Chalam, K V
2001-01-01
Wide-field vitrectomy contact lenses are currently sterilized with ethylene oxide gas, and other lenses with autoclaving. To maintain a large inventory or possibly run the risk of loss of lens quality with repeated autoclaving, glutaraldehyde 2% and povidone iodine 5% solution were evaluated as possible sterilizing agents. Ethylene oxide presterilized lenses were contaminated with known concentrations (10(5) organisms/mL) of bacteria (S. epidemidis, P. aeruginosa, B. subtilis), and fungi (A. flavus, C. albicans) for 5 minutes. The test lenses were treated with glutaraldehyde or povidone iodine for 5, 10, 30, 60, and 120 minutes, and controls with sterilized water for a similar duration. Following treatment, both test and control lenses were sampled with sterile cotton swabs. The swabs were cultured for bacteria (tryptone soya broth 48 hours), and fungi (Saubourd's dextrose broth 5 days). The culture was negative for both glutaraldehyde- and povidone iodine-treated lenses against all organisms at all time points except B subtilis, which needed 120 minutes treatment. Two hours contact time with glutaraldehyde 2% or providone iodine 5% can sterilize vitrectomy contact lenses against common bacteria and fungi without affecting lens quality.
Effect of phospholipid deposits on adhesion of bacteria to contact lenses.
Babaei Omali, Negar; Proschogo, Nicholas; Zhu, Hua; Zhao, Zhenjun; Diec, Jennie; Borazjani, Roya; Willcox, Mark D P
2012-01-01
Protein and lipid deposits on contact lenses may contribute to clinical complications. This study examined the effect of phospholipids on the adhesion of bacteria to contact lenses. Worn balafilcon A (n = 11) and senofilcon A (n = 11) were collected after daily wear and phospholipids were extracted in chloroform:methanol. The amount of phospholipid was measured by electrospray ionization mass spectrometry. Unworn lenses soaked in phospholipids were exposed to Pseudomonas aeruginosa and Staphylococcus aureus. After 18 h incubation, the numbers of P. aeruginosa or S. aureus that adhered to the lenses were measured. Phospholipid was tested for possible effects on bacterial growth. A broad range of sphingomyelins (SM) and phosphatidylcholines (PC) were detected from both types of worn lenses. SM (16:0) (m/z 703) and PC (34:2) (m/z 758) were the major phospholipids detected in the lens extracts. Phospholipids did not alter the adhesion of any strain of P. aeruginosa or S. aureus (p > 0.05). Phospholipids (0.1 mg/mL) showed no effect on the growth of P. aeruginosa 6294 or S. aureus 031. Phospholipids adsorb/absorb to contact lenses during wear, however, the major types of phospholipids adsorbed to lenses do not alter bacterial adhesion or growth.
Dutta, Debarun; Zhao, Timothy; Cheah, Kai Bing; Holmlund, Larke; Willcox, Mark D P
2017-06-01
To determine the antimicrobial activity of the melimine derived peptide Mel4 against Delftia, Stenotrophomonas, Elizabethkingia, Burkholderia and to investigate biocompatibility of Mel4 as an antimicrobial coating on contact lenses in animals and humans. In vitro antimicrobial activity of Mel4 was determined against the four Gram negative bacteria by investigating growth curves for 24h followed by viable counts to determine the minimum inhibitory concentration (MIC). Contact lenses were coated by covalently binding Mel4, characterized by amino acid analysis, and were investigated for changes in lens parameters. Safety of Mel-4 coated lenses were determined in a rabbit model of daily contralateral wear. A prospective, randomised, double-masked, contralateral, 1week daily wear human clinical trial was used to evaluate subjective responses and ocular physiology. Mel4 was active against all the bacteria tested (MIC 50 ranged from 31-1000μgml -1 ) and produced an antimicrobial surface on contact lenses. Mel4-coating resulted hydrophilic surface without any significant change in contact lens parameters, and showed no signs of cytotoxicity or ocular irritation during rabbit wear. During human clinical trial, there were no differences between Mel4 coated and uncoated contact lenses in lens performance indicators and ocular signs such as corneal fluorescein staining. Mel4 and control uncoated lenses had no differences in ocular symptoms during lens wear. Mel4 has achieved antimicrobial activity against variety of Gram negative bacteria that are often resistant to the action of cationic peptides and have been implicated in contact lens related adverse events. Mel4-coated contact lenses were safe to wear. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Immunoglobulin Concentration in Tears of Contact Lens Wearers
Maurya, Rajendra P.; Bhushan, Prashant; Singh, Virendra P.; Singh, Mahendra K.; Kumar, Prakash; Bhatia, Ravindra P.S.; Singh, Usha
2014-01-01
Purpose: To evaluate changes in the concentration of tear immunoglobulins in contact lens wearers. Methods: A total of 45 cases including 23 contact lens wearers (43 eyes) and 22 age and sex matched healthy controls having no ocular pathology were studied for immunoglobulins (IgA, IgG, IgM) in their tears by single radial immunodiffusion method. Results: Most of the cases used soft (56.6%) and semi-soft gas permeable (30.4%) contact lenses. Tear IgM was detected in only 17.4% and tear IgG in 43.6% of contact lens wearers, while in controls IgG was detected in 9.1% but none of the controls had IgM. There was a significant rise in total tear IgA (13.17 ± 4.44 mg/dl) in contact lens wearer as compared to controls (8.93 ± 3.79 mg/dl). Rise of tear IgA was more in symptomatic patients (15.38 ± 5.28 mg/dl) and in those wearing hard (19.73 ± 5.43 mg/dl) and semi-soft contact lenses (13.31 ± 5.43 mg/dl). A significant increase in tear IgA was noticed in subjects wearing lenses for >3 years (15.69 ± 5.39 mg/dl). About 43.4% of lens wearers were symptomatic and 80% of their lenses showed deposits and/or haziness. All cases with IgM in tear were symptomatic. Conclusion: The relation of immunoglobulin concentration with increasing duration of wear and material of contact lens shows that tear immunoglobulin rise accrues due to mechanical stimulation, hence contact lenses should not be used for a long period and lenses of hard nature should be discouraged. The maintenance, cleaning and deproteinization of the lenses are of high importance to avoid immunostimulation. PMID:25667732
Soft Contact Lens Wear at Altitude: Effects of Hypoxia
1988-01-01
conjunctiva (2). If the edema is severe, breakdown of some and aircraft with cabin pressures equivalent to lower altitudes, of the epithelial cells from...debris, conjunctival injection, and corneal epithelial of hydrogel lenses. International Contact Lens Clinic. 1983. staining, showed heightened...cornea may be severe enough to affect vision stnae accompanying the wearing of hydrogel lenses. Am. J. and preclude wearing soft contact lenses during
Development of Ciprofloxacin-loaded contact lenses using fluorous chemistry
Zhu, Zhiling; Li, Siheng; McDermott, Alison M.
2017-01-01
In this work, we developed a simple method to load drugs into commercially available contact lenses utilizing fluorous chemistry. We demonstrated this method using model compounds including fluorous-tagged fluorescein and antibiotic ciprofloxacin. We showed that fluorous interactions facilitated the loading of model molecules into fluorocarbon-containing contact lenses, and that the release profiles exhibited sustained release. Contact lenses loaded with fluorous-tagged ciprofloxacin exhibited antimicrobial activity against Pseudomonas aeruginosa in vitro, while no cytotoxicity towards human corneal epithelial cells was observed. To mimic the tear turnover, we designed a porcine eye infection model under flow conditions. Significantly, the modified lenses also exhibited antimicrobial efficacy against Pseudomonas aeruginosa in the ex vivo infection model. Overall, utilizing fluorous chemistry, we can construct a drug delivery system that exhibits high drug loading capacity, sustained drug release, and robust biological activity. PMID:28188995
Prescribing prophylactic antibiotics to users of therapeutic contact lenses.
Colomé-Campos, J; Quevedo-Junyent, L; Godoy-Barreda, N; Martínez-Salcedo, I; Romero-Aroca, P
2013-03-01
To describe the benefits and optimum use of prophylactic antibiotics in users of therapeutic contact lenses (TCL). A microbiological study was carried out on samples from 33 patients who continuously wore TCL. The resistance to antibiotics of bacteria isolated in our health region was also reviewed. An assessment was also made on whether there were microorganisms of a higher pathogenic potential in TCL than conventional contact lenses, as reported in the literature. No bacteria were isolated from 17 (52%) of the 33 lenses studied. From the 16 (48%) remaining lenses, coagulase negative Staphylococci were isolated from 10 (62%), Propionibacterium acnes from 4 (25%), and Corynebacterium from 2 (13%). The high number of negative cultures and the presence of saprophytic bacteria indicate that prophylactic antibiotic treatment is not precise. The most frequent pathogenic bacteria found in contact lenses are strongly resistant to the current commercially available antibiotics. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Effect of cholesterol deposition on bacterial adhesion to contact lenses.
Babaei Omali, Negar; Zhu, Hua; Zhao, Zhenjun; Ozkan, Jerome; Xu, Banglao; Borazjani, Roya; Willcox, Mark D P
2011-08-01
To examine the effect of cholesterol on the adhesion of bacteria to silicone hydrogel contact lenses. Contact lenses, collected from subjects wearing Acuvue Oasys or PureVision lenses, were extracted in chloroform:methanol (1:1, v/v) and amount of cholesterol was estimated by thin-layer chromatography. Unworn lenses were soaked in cholesterol, and the numbers of Pseudomonas aeruginosa strains or Staphylococcus aureus strains that adhered to the lenses were measured. Cholesterol was tested for effects on bacterial growth by incubating bacteria in medium containing cholesterol. From ex vivo PureVision lenses, 3.4 ± 0.3 μg/lens cholesterol was recovered, and from Acuvue Oasys lenses, 2.4 ± 0.2 to 1.0 ± 0.1 μg/lens cholesterol was extracted. Cholesterol did not alter the total or viable adhesion of any strain of P. aeruginosa or S. aureus (p > 0.05). However, worn PureVision lenses reduced the numbers of viable cells of P. aeruginosa (5.8 ± 0.4 log units) compared with unworn lenses (6.4 ± 0.2 log units, p = 0.001). Similarly, there were fewer numbers of S. aureus 031 adherent to worn PureVision (3.05 ± 0.8 log units) compared with unworn PureVision (4.6 ± 0.3 log units, p = 0.0001). Worn Acuvue Oasys lenses did not affect bacterial adhesion. Cholesterol showed no effect on the growth of any test strain. Although cholesterol has been shown to adsorb to contact lenses during wear, this lipid does not appear to modulate bacterial adhesion to a lens surface.
NASA Astrophysics Data System (ADS)
Filipecka, Katarzyna; Budaj, Mariusz; Chamerski, Kordian; Miedziński, Rafał; Sitarz, Maciej; Miskowiak, Bogdan; Makowska-Janusik, Małgorzata; Filipecki, Jacek
2017-11-01
Studies on polymeric materials used in contactology for manufacturing of contact lenses are presented in the paper. Different types of brand new contact lenses were investigated: hydrogel, silicone-hydrogel and rigid gas permeable. Positron annihilation lifetime spectroscopy (PALS) was used to characterize geometrical sizes and fraction of the free volume holes in the investigated samples. Measurements reveal significant differences between the materials. Namely differences in size and fraction of free volume were observed. These changes are strongly correlated with oxygen permeability in contact lenses. Middle infrared (MIR) spectroscopy was carried out in order to investigate the internal structure of materials. Furthermore, UV-vis-NIR studies were performed in order to determine the transmittance properties of contact lenses.
Proteomic analysis of protein deposits on worn daily wear silicone hydrogel contact lenses
Wei, Xiaojia; Aliwarga, Yulina; Carnt, Nicole A.; Garrett, Qian; Willcox, Mark D.P.
2008-01-01
Purpose Previous studies have demonstrated deposition of tear proteins onto worn contact lenses. In this study, we used proteomic techniques to analyze the protein deposits extracted from worn daily wear silicone hydrogel contact lenses in combination with different lens care solutions. Methods Worn lenses were collected and protein deposits extracted using urea and surfactant. Protein extracts were desalted, concentrated, and then separated using one-dimensional gel electrophoresis. Individual protein components in extracts were identified using liquid chromatography combined with tandem mass spectrometry (LC-MS-MS) after trypsin digestion. Results One-dimensional gel electrophoresis revealed that lysozyme and other small proteins (around 20 kDa) were the most abundant proteins in the extracts. LC-MS-MS revealed a wide array of proteins in lens extracts with lysozyme and lipocalin 1 being the most commonly identified in deposit extracts. Conclusions Worn contact lenses deposit a wide array of proteins from tear film and other sources. Protein deposit profiles varied and were specific for each contact lens material. PMID:18989384
Technical Guide for Indoor Air Quality Surveys
2014-07-24
inability to wear contact lenses; and dry, itchy, flaking skin [16,23]. The number of persons affected increases as the relative humidity decreases below...40%. The inability to wear contact lenses in a building with low relative humidity results from fluid loss from the exposed outer eye surface...eye and may enhance the possibility of an infection. Even without contact lenses, the eyes can feel dry, irritated, and itchy. Low relative
Effect of surfactant chain length on drug release kinetics from microemulsion-laden contact lenses.
Maulvi, Furqan A; Desai, Ankita R; Choksi, Harsh H; Patil, Rahul J; Ranch, Ketan M; Vyas, Bhavin A; Shah, Dinesh O
2017-05-30
The effect of surfactant chain lengths [sodium caprylate (C 8 ), Tween 20 (C 12 ), Tween 80 (C 18 )] and the molecular weight of block copolymers [Pluronic F68 and Pluronic F 127] were studied to determine the stability of the microemulsion and its effect on release kinetics from cyclosporine-loaded microemulsion-laden hydrogel contact lenses in this work. Globule size and dilution tests (transmittance) suggested that the stability of the microemulsion increases with increase in the carbon chain lengths of surfactants and the molecular weight of pluronics. The optical transmittance of direct drug-laden contact lenses [DL-100] was low due to the precipitation of hydrophobic drugs in the lenses, while in microemulsion-laden lenses, the transmittance was improved when stability of the microemulsion was achieved. The results of in vitro release kinetics revealed that drug release was sustained to a greater extent as the stability of microemulsion was improved as well. This was evident in batch PF127-T80, which showed sustained release for 15days in comparison to batch DL-100, which showed release up to 7days. An in vivo drug release study in rabbit tear fluid showed significant increase in mean residence time (MRT) and area under curve (AUC) with PF-127-T80 lenses (stable microemulsion) in comparison to PF-68-SC lenses (unstable microemulsion) and DL-100 lenses. This study revealed the correlation between the stability of microemulsion and the release kinetics of drugs from contact lenses. Thus, it was inferred that the stable microemulsion batches sustained the release of hydrophobic drugs, such as cyclosporine from contact lenses for an extended period of time without altering critical lens properties. Copyright © 2017 Elsevier B.V. All rights reserved.
Demodex sp. as a Potential Cause of the Abandonment of Soft Contact Lenses by Their Existing Users
Tarkowski, Witold; Moneta-Wielgoś, Joanna; Młocicki, Daniel
2015-01-01
Demodex mites may be a potential etiological factor in the development of various eye and skin disorders. The aim of the study was to investigate the presence of Demodex in the hair follicles of eyelashes and their potential influence on abandoning soft contact lenses which had been previously well tolerated by their users. A group of 62 users of contact lenses (28 with emerging discomfort and 34 without discomfort) were examined. There is a need to check the existence of a relationship between D. folliculorum or/and D. brevis infestation and the emergence of intolerance to the presence of soft contact lenses. The removed lashes were examined under light microscopy, applying standard parasitological methods if demodicosis is suspected. A positive result was assumed if at least one adult stage, larva, protonymph/nymph, or egg of D. folliculorum and/or D. brevis was present. A positive correlation was observed between the presence of Demodex and intolerance to contact lenses by their existing users (p < 0.05), and Demodex sp. infections were observed in 92.86% of patients with intolerance to contact lenses. Our results provide further evidence for the pathogenic role played by the mites in the development of eye diseases. PMID:26290865
White, Charles J; McBride, Matthew K; Pate, Kayla M; Tieppo, Arianna; Byrne, Mark E
2011-08-01
Symptoms of contact lenses induced dry eye (CLIDE) are typically treated through application of macromolecular re-wetting agents via eye drops. Therapeutic soft contact lenses can be formulated to alleviate CLIDE symptoms by slowly releasing comfort agent from the lens. In this paper, we present an extended wear silicone hydrogel contact lens with extended, controllable release of 120 kDa hydroxypropyl methylcellulose (HPMC) using a molecular imprinting strategy. A commercial silicone hydrogel lens was tailored to release approximately 1000 μg of HPMC over a period of up to 60 days in a constant manner at a rate of 16 μg/day under physiological flowrates, releasing over the entire range of continuous wear. Release rates could be significantly varied by the imprinting effect and functional monomer to template ratio (M/T) with M/T values 0, 0.2, 2.8, 3.4 corresponding to HPMC release durations of 10, 13, 23, and 53 days, respectively. Lenses had high optical quality and adequate mechanical properties for contact lens use. This work highlights the potential of imprinting in the design and engineering of silicone hydrogel lenses to release macromolecules for the duration of wear, which may lead to decreased CLIDE symptoms and more comfortable contact lenses. Copyright © 2011 Elsevier Ltd. All rights reserved.
Parks, Quinn M.; Young, Robert L.; Kret, Jennifer; Poch, Katie R.; Malcolm, Kenneth C.; Nichols, David P.; Nichols, Michelle; Zhu, Meifang; Cavanagh, H. Dwight; Nick, Jerry A.
2011-01-01
Purpose. To evaluate the capacity of neutrophils to enhance biofilm formation on contact lenses by an infectious Pseudomonas aeruginosa (PA) corneal isolate. Agents that target F-actin and DNA were tested as a therapeutic strategy for disrupting biofilms formed in the setting of neutrophils in vitro and for limiting the infectious bioburden in vivo. Methods. Biofilm formation by infectious PA strain 6294 was assessed in the presence of neutrophils on a static biofilm plate and on unworn etafilcon A soft contact lenses. A d-isomer of poly(aspartic acid) was used alone and with DNase to reduce biofilm formation on test contact lenses. The gentamicin survival assay was used to determine the effectiveness of the test compound in reducing subsequent intracellular bacterial load in the corneal epithelium in a contact lens infection model in the rabbit. Results. In a static reactor and on hydrogel lenses, PA biofilm density was enhanced 30-fold at 24 hours in the presence of neutrophils (P < 0.0001). The combination of DNase and anionic poly(aspartic acid) reduced the PA biofilms formed in the presence of activated neutrophils by 79.2% on hydrogel contact lenses (P < 0.001). An identical treatment resulted in a 41% reduction in internalized PA in the rabbit corneal epithelium after 24 hours (P = 0.03). Conclusions. These results demonstrate that PA can exploit the presence of neutrophils to form biofilm on contact lenses within a short time. Incorporation of F-actin and DNA represent a mechanism for neutrophil-induced biofilm enhancement and are targets for available agents to disrupt pathogenic biofilms formed on contact lenses and as a treatment for established corneal infections. PMID:21245396
García-Lázaro, Santiago; Ferrer-Blasco, Teresa; Madrid-Costa, David; Albarrán-Diego, César; Montés-Micó, Robert
2015-01-01
To assess and compare the effects of four simultaneous-image multifocal contact lenses (SIMCLs), and those with distant-vision-only contact lenses on visual performance in early presbyopes, under dim conditions, including the effects of induced glare. In this double-masked crossover study design, 28 presbyopic subjects aged 40 to 46 years were included. All participants were fitted with the four different SIMCLs (Air Optix Aqua Multifocal [AOAM; Alcon], PureVision Multifocal [PM; Bausch & Lomb], Acuvue Oasys for Presbyopia [AOP; Johnson & Johnson Vision], and Biofinity Multifocal [BM; CooperVision]) and with monofocal contact lenses (Air Optix Aqua, Alcon). After 1 month of daily contact lens wearing, each subject's binocular distance visual acuity (BDVA) and binocular distance contrast sensitivity (BDCS) were measured using the Functional Visual Analyzer (Stereo Optical Co., Inc.) under mesopic conditions (3 candela [cd]/m) both with no glare and under the 2 levels of induced glare: 1.0 lux (glare 1) and 28 lux (glare 2). Among the SIMCLs, in terms of BDVA, AOAM and PM outperformed BM and AOP. All contact lenses performed better at level without glare, followed by Glare 1, and with the worst results obtained under glare 2. Binocular distance contrast sensitivity revealed statistically significant differences for 12 cycles per degree (cpd). Among the SIMCLs, post hoc multiple comparison testing revealed that AOAM and PM provided the best BDCS at the three luminance levels. In both cases, BDVA and BDCS at 12 cpd, monofocal contact lenses outperformed all SIMCL ones at all lighting conditions. Air Optix Aqua Multifocal and PM provided better visual performance than BM and AOP for distance vision with low addition and under dim conditions, but they all provide worse performance than monofocal contact lenses.
Sermsathanasawadi, Nuttawut; Chatjaturapat, Choedpong; Pianchareonsin, Rattana; Puangpunngam, Nattawut; Wongwanit, Chumpol; Chinsakchai, Khamin; Ruangsetakit, Chanean; Mutirangura, Pramook
2017-08-01
Compression bandaging is a major treatment of chronic venous ulcers. Its efficacy depends on the applied pressure, which is dependent on the skill of the individual applying the bandage. To improve the quality of bandaging by reducing the variability in compression bandage interface pressures, we changed elastic bandages into a customised version by marking them with circular ink stamps, applied when the stretch achieves an interface pressure between 35 and 45 mmHg. Repeated applications by 20 residents of the customised bandage and non-marked bandage to one smaller and one larger leg were evaluated by measuring the sub-bandage pressure. The results demonstrated that the target pressure range is more often attained with the customised bandage compared with the non-marked bandage. The customised bandage improved the efficacy of compression bandaging for venous ulcers, with optimal sub-bandage pressure. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Koh, Shizuka; Maeda, Naoyuki; Hamano, Takashi; Hirohara, Yoko; Mihashi, Toshifumi; Hori, Yuichi; Hosohata, Jun; Fujikado, Takashi; Tano, Yasuo
2008-03-01
To investigate whether the polymer composition of disposable soft contact lenses affects sequential changes in higher-order aberrations (HOAs). Fifteen subjects who wore disposable soft contact lenses with dryness-related symptoms and 15 non-contact lens wearers were enrolled in this study. Ocular HOAs were measured for 60 seconds in each subject wearing a disposable etafilcon A lens (conventional lens) or a disposable etafilcon A lens with polyvinyl pyrrolidone (PVP) (lens with PVP) after 1 hour of contact lens wear. During the measurement, subjects were forced to blink every 10 seconds. The aberration data were analyzed in the central 4-mm diameter up to the sixth-order Zernike polynomials. Total HOAs, the fluctuation index (FI), and the stability index (SI) of the total HOAs over time were compared between the two groups. The subjective ocular dryness also was scored. In symptomatic wearers of disposable soft contact lenses, the total HOAs, the FI, and the SI with the lens with PVP were significantly (P=0.013, P=0.014, P=0.019, respectively) lower than with the conventional lens, whereas a significant (P=0.018) difference between the two lenses was observed only in the FI in non-contact lens wearers. Subjective ocular dryness with the lens with PVP significantly decreased compared with the conventional lens in both groups. Sequential measurement of HOAs may be a useful objective method to evaluate the effect of internal lubricating agents of disposable soft contact lenses on optical quality.
Del Águila-Carrasco, Antonio J; Domínguez-Vicent, Alberto; Pérez-Vives, Cari; Ferrer-Blasco, Teresa; Montés-Micó, Robert
2015-01-01
To assess the effect of different disposable soft contact lenses on several corneal parameters-thickness, anterior and posterior curvature, and volume-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour period of contact lens wear. Measurements were also taken without any contact lenses being worn. Regarding corneal thickness, the lens with the most similar behavior to the naked eye scenario was the Dailies Total1, causing a thickening of 0.2 ± 0.1% in the central zone and 0.6 ± 0.2% in the periphery. All 4 lenses caused a slight but not significant flattening in the anterior corneal curvature, whereas the posterior corneal curvature only experienced a significant but small steepening with the SofLens. The use of these lenses increased corneal volume slightly. Variations in corneal parameters seem to depend on the type of contact lens used (material, oxygen transmissibility, water content). However, the magnitude of the changes introduced by the use of soft contact lenses over the 8-hour period was small and probably not large enough to influence either visual acuity or comfort.
Hill, J F
1980-08-01
The purpose of this study was to compare the clinical acceptability of polymacon spin-cast to polymacon lathe-cut hydrophilic contact lenses. Ten patients successfully wearing polymacon spin-cast lenses were studied. Each patient had one eye refitted with polymacon lathe-cut lenses. Comparison of the two types of lenses was then made. Objective evaluation included centration, movement, visual acuity, and over-refraction. Subjective criteria were based on patient comfort and stability and quality of vision. Results indicate that lathe-cut lenses can be just as clinically satisfactory as the spincast ones.
Omaña-Molina, Maritza A; González-Robles, Arturo; Salazar-Villatoro, Lizbeth; Bernal-Escobar, Alexander; Durán-Díaz, Angel; Méndez-Cruz, Adolfo René; Martínez-Palomo, Adolfo
2014-05-01
To describe the adhesion properties of Acanthamoeba castellanii trophozoites to silicone hydrogel contact lenses of first generation (lotrafilcon A), second generation (galyfilcon A), and third generation (comfilcon A) and correlate the results with their specific surface characteristics, time of interaction, and suspension media. Qualitative and quantitative assessments of the adhesion of 200 trophozoites of A. castellanii on contact lenses in culture medium (Bacto Casitone) and isotonic saline (IS) at different time points (15 minutes and 6 hours) were determined. By scanning electron microscopy, A. castellanii trophozoites were observed firmly adhered to the surface of hydrogel lenses after 15 minutes of interaction. The surface of lotrafilcon A lenses on which amoebae adhere better (16.4±10.2 amoebae/lens section) is rough and folded, which increases the contact surface with trophozoites, allowing acanthopodia to attach firmly. Contrarily, galyfilcon A lenses have a smoother surface, and lower numbers of amoebae were observed adhered to these lenses (4.7±2.9 amoebae/lens section). Even fewer amoebae adhered to the smoother surface of the comfilcon A lens (2.2±1.7 amoebae/lens section). Trophozoites showed similar behavior in both Bacto Casitone medium and IS. A rough surface may contribute to better adhesion of amoebae to silicone hydrogel lenses. Although a reduced numbers of trophozoites adhered to smooth lenses, trophozoites are a risk factor for amoebic keratitis. Isotonic saline facilitated trophozoite survival, suggesting that homemade saline solutions may contribute to the persistence of trophozoites, especially when there is no proper hygiene regimen used with the contact lens cases.
Sermsathanasawadi, Nuttawut; Tarapongpun, Tanakorn; Pianchareonsin, Rattana; Puangpunngam, Nattawut; Wongwanit, Chumpol; Chinsakchai, Khamin; Mutirangura, Pramook; Ruangsetakit, Chanean
2017-01-01
Objective A randomized clinical trial was performed to compare the effectiveness of unmarked bandages and customized bandages with visual markers in reproducing the desired sub-bandage pressure during self-bandaging by patients. Method Ninety patients were randomly allocated to two groups ("customized bandages" and "unmarked bandages") and asked to perform self-bandaging three times. The achievement of a pressure between 35 and 45 mmHg in at least two of the three attempts was defined as adequate quality. Results Adequate quality was achieved by 33.0% when applying the unmarked bandages, and 60.0% when applying the customized bandages ( p = 0.02). Use of the customized bandage and previous experience of bandaging were independent predictors for the achievement of the predetermined sub-bandage pressure ( p = 0.005 and p = 0.021, respectively). Conclusion Customized bandages may achieve predetermined sub-bandage pressures more closely than standard, unmarked, compression bandages. Clinical trials registration ClinicalTrials.gov (NCT02729688). Effectiveness of a Pressure Indicator Guided and a Conventional Bandaging in Treatment of Venous Leg Ulcer. https://clinicaltrials.gov/ct2/show/NCT02729688.
Peripheral corneal infiltrates associated with contact lens wear.
Donshik, P C; Suchecki, J K; Ehlers, W H
1995-01-01
PURPOSE: A retrospective study was performed to review the clinical characteristics of peripheral corneal infiltrates in contact lens wearers. METHODS: The charts of all contact lens patients with peripheral corneal infiltrates 1.5 mm or less in size who presented to the office from 1987 to 1994 were reviewed. RESULTS: The epidemiological and clinical characteristics of peripheral corneal infiltrates associated with contact lens wear were reviewed in 52 patients (64 infiltrates). Forty-four patients presented with a single infiltrate, while the remaining 8 patients had multiple infiltrates. While there was no predilection for a specific quadrant of the cornea, when a subgroup of patients who wore extended wear lenses was analyzed, 19 of the 40 infiltrates were located in the superior quadrant. Forty percent of the patients were wearing disposable extended wear contact lenses, 21% were wearing conventional extended wear lenses, 33% were wearing conventional or frequent replacement/disposable daily wear contact lenses and 6% were wearing rigid gas permeable lenses. The majority of patients had minimal conjunctival inflammation, an anterior stromal cellular reaction and minimal anterior chamber activity. A subgroup of 16 patients had corneal cultures of their infiltrates. In this group, 8 of the 16 had positive cultures. All patients had a resolution of the infiltrates without complications and the majority were refitted to daily wear soft or rigid contact lenses. CONCLUSION: Peripheral corneal infiltrates in contact lens wearers appears to be more common in patients wearing extended wear soft contact lenses. While often considered "sterile" in the literature, a significant number have been shown to be culture-positive. The organisms that have been associated with peripheral infiltrates appear to be less "pathogenic" than those that have been reported to be associated with central corneal ulcer. However, it is probably advisable that patients with peripheral corneal ulcers secondary to contact lens wear should be initially treated with topical antibiotics. PMID:8719670
Daily disposable contact lens prescribing around the world.
Efron, Nathan; Morgan, Philip B; Helland, Magne; Itoi, Motozumi; Jones, Deborah; Nichols, Jason J; van der Worp, Eef; Woods, Craig A
2010-10-01
Daily disposable contact lenses were introduced into the market 16 years ago. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, The Netherlands, Norway, the UK and the USA between 2000 and 2008 indicates an overall increase in daily disposable lens fitting during this period. Daily disposable lenses are especially popular in Japan, Norway and the UK. There is a trend for these lenses to be fitted on a part-time basis. Males are over-represented in daily disposable lens fitting-a trend that is especially evident in Canada. Daily disposable lens wearers are about two years younger than wearers of reusable lenses in Japan and The Netherlands. The convenience and health benefits of daily disposable lenses are expected to fuel continued growth in this sector. Copyright (c) 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Afzha, Rooh; Chatterjee, Anirban; Subbaiah, Shobha Krishna; Pradeep, Avani Rangaraju
2016-01-01
Ultrasonic scaler is a preferential treatment modality among the clinicians. However, the aerosol/splatter generated is a concern for patients and practitioners. Therefore, the purpose of this study was to evaluate contamination of contact lenses of the dentist after scaling and root planing using ultrasonic scalers with and without protective eyewear. Thirty patients were randomly selected for scaling and root planing and divided into 2 groups of 15 each. Group A - dentist wearing contact lenses and protective eyewear. Group B - dentist wearing only contact lenses. After scaling and root planing using ultrasonic scalers, the lenses were subjected to culture and 16S rRNA (16S ribosomal RNA) gene sequencing. In Group A - 15 out of thirty samples were contaminated, in Group B - all the thirty samples were contaminated. Most of the samples showed Gram-positive bacteria and 5 samples were contaminated with fungi. 16S rRNA gene sequencing of forty contaminated samples showed that 31 were contaminated with Streptococcus mutans and 9 with Staphylococcus aureus. Keeping in mind the limitation of the study for the absence of negative control, we would like to conclude that dental practitioners should better avoid contact lenses in a dental setup because of the risk of contamination of the contact lenses from the various dental procedures which can produce aerosol/splatter and if worn, it is recommended to wear protective eyewear.
Afzha, Rooh; Chatterjee, Anirban; Subbaiah, Shobha Krishna; Pradeep, Avani Rangaraju
2016-01-01
Background: Ultrasonic scaler is a preferential treatment modality among the clinicians. However, the aerosol/splatter generated is a concern for patients and practitioners. Therefore, the purpose of this study was to evaluate contamination of contact lenses of the dentist after scaling and root planing using ultrasonic scalers with and without protective eyewear. Materials and Methods: Thirty patients were randomly selected for scaling and root planing and divided into 2 groups of 15 each. Group A – dentist wearing contact lenses and protective eyewear. Group B - dentist wearing only contact lenses. After scaling and root planing using ultrasonic scalers, the lenses were subjected to culture and 16S rRNA (16S ribosomal RNA) gene sequencing. Results: In Group A – 15 out of thirty samples were contaminated, in Group B – all the thirty samples were contaminated. Most of the samples showed Gram-positive bacteria and 5 samples were contaminated with fungi. 16S rRNA gene sequencing of forty contaminated samples showed that 31 were contaminated with Streptococcus mutans and 9 with Staphylococcus aureus. Conclusion: Keeping in mind the limitation of the study for the absence of negative control, we would like to conclude that dental practitioners should better avoid contact lenses in a dental setup because of the risk of contamination of the contact lenses from the various dental procedures which can produce aerosol/splatter and if worn, it is recommended to wear protective eyewear. PMID:27563200
Vidotti, Vanessa Gonçalves; Kamegasawa, Amélia
2006-01-01
To analyze the ametropy, way of acquisition, the care and complications related to contact lens wear among medical students from Faculdade de Medicina de Botucatu da Universidade Estadual Paulista-UNESP--Botucatu (SP). Questionnaire applied to students from the 1st to the 6th year of the Medical school of the Faculdade de Medicina de Botucatu da Universidade Estadual Paulista-UNESP--Botucatu (SP), forming an analytical cross-sectional survey. 27.4% of the students use contact lenses, and among them 94.8% use soft contact lenses and 98% have negative degree. 46.9% discard their contact lens monthly. 63.9% have an average daily use of 14 hours, 14.1% acquire the contact lenses from optician stores or at pharmacies and 46.5% of the students clean their contact lenses when they put them on and take them off. Regarding complications, 51.0% reported ocular redness; 44.5%, blurred vision; and 42.6%, foreign body sensation, whereas only 4 students reported "keratitis". We concluded that the inadequate adaptation that occurs even in users knowledgeable about this issue such as medical students, has increased the risk of complications. This fact indicates that more attention must be paid to contact lens care in order to prevent permanent visual deficit.
Oxygen permeability of hydrogel contact lenses with organosilicon moieties.
Compañ, V; Andrio, A; López-Alemany, A; Riande, E; Refojo, M F
2002-07-01
Oxygen transport through two extended wear (day and night) hydrogel contact lenses that contain organosilicon moieties (balafilcon A and lotrafilcon A) was studied in the hydrate (hydrogel) and dry (xerogel) states. The water uptake increased the oxygen permeability [(Dk)app] and transmissibility [Dk/L(av)] coefficients of the dry materials by about 70%. The (Dk)app for the hydrated lenses was determined following the so-called stack procedure. The values obtained were 107 +/- 4 barrer for balafilcon A and 141 +/- 5 barrer for lotrafilcon A, about 5-10 times larger than those previously reported for conventional (without organosilicon moieties) extended wear hydrogels contact lenses. The Dk/L(av) for -3.00 diopter lenses (harmonic average thickness, L(av) = 75 +/- 2 microm for lotrafilcon, and 85 +/- 2 microm for balafilcon) was 123 +/- 6 barrer/cm for balafilcon A and 183 +/- 8 barrer/cm for lotralicon A. The minimum oxygen transmissibility 87 barrer/cm stipulated by Holden and Mertz to avoid corneal edema with extended wear contact can be easily achieved with lotrafilcon and balafilcon lenses of diverse dioptric powers if the central and peripheral thickness of the lenses are kept below the critical level of oxygen transmissibility.
Cope, Jennifer R; Collier, Sarah A; Schein, Oliver D; Brown, Allison C; Verani, Jennifer R; Gallen, Rachel; Beach, Michael J; Yoder, Jonathan S
2016-07-01
To describe the clinical presentation and outcomes of Acanthamoeba keratitis (AK) in rigid gas permeable (RGP) contact lens wearers and to identify modifiable risk factors. Case-control investigation. Patients were RGP contact lens-wearing United States residents with a diagnosis of AK from 2005 through 2011. Controls were RGP contact lens wearers with no history of AK who were at least 12 years of age. Patients were identified during 2 multistate AK outbreak investigations. Controls from the first investigation in 2007 were identified using a reverse address directory. In the second investigation, controls were recruited from participating ophthalmology and optometry practices. Patients and controls were interviewed by phone using a standardized questionnaire. Odds ratios (ORs) and Fisher exact P values were calculated to assess risk factors associated with infection. Acanthamoeba keratitis, a rare eye disease primarily affecting contact lens wearers, is caused by free-living amebae, Acanthamoeba species. We identified 37 patients in the 2 investigations, 10 (27%) from the 2007 investigation and 27 (73%) from 2011. There were 17 healthy controls, 9 (53%) from 2007 and 8 (47%) from 2011. Among patients, 9 (24%) wore RGP lenses for orthokeratology or therapeutic indication; no controls wore RGP lenses for these indications. Significant risk factors for AK were wearing lenses for orthokeratology (OR, undefined; P = 0.02), sleeping while wearing lenses (OR, 8.00; P = 0.04), storing lenses in tap water (OR, 16.00; P = 0.001), and topping off contact lens solution in the case (OR, 4.80; P = 0.01). After stratifying by use of RGP lenses for orthokeratology, storing lenses in tap water and topping off remained significant exposures. Nearly one quarter of patients were orthokeratology wearers. Using tap water to store RGP lenses and topping off solution in the lens case were modifiable risk behaviors identified in RGP wearers who wore lenses for both orthokeratology and nonorthokeratology indications. Rigid gas permeable wearers should avoid exposing their lenses to tap water and should empty their cases and use fresh lens solution each time they take out their lenses. Published by Elsevier Inc.
... are Sunglasses Safety goggles Glasses (also called eyeglasses) Contact lenses If you need corrective lenses, you may be able to choose between contacts or glasses. Either usually requires a prescription. Almost ...
Sousa, Sidney Júlio de Faria E; Dias, Vanderson Glerian; Marcomini, Luís Antonio Gorla
2008-01-01
This is the report of a case of bilateral Acanthamoeba keratitis in a 19-year-old woman who bought a pair of disposable soft contact lenses in a boutique. She wore this same pair of lenses for 3 months daily without the appropriate care. This led to bilateral corneal transplantation with cataract extraction and also trabeculectomy in the right eye. When last seen, both grafts were crystal clear but the visual acuities were far from satisfactory. She also had bilateral secondary glaucoma, barely controlled by topical medication. Actually, the physical features and the wearing time characteristics of the disposable soft contact lenses created unprecedented difficulties to the medical surveillance of their wearers. Without the right assistance they tend to become careless regarding routine cleaning. They also feel free to buy less expensive lenses, to use saline instead of lens solutions, to violate the limits of wearing time and to extend the use over the sleeping period. Additionally, the aggressive marketing and the wide distribution of these lenses increase the chances that economically or educationally unprepared people will acquire them. The question that remains is: Is the present case an accidental event or an example of what is likely to happen in the future if the indiscriminate selling of disposable soft contact lenses continues to evolve?
Infections after PRK could have a happy ending: a series of three cases.
Bertschinger, D R; Hashemi, K; Hafezi, F; Majo, F
2010-04-01
Infectious keratitis after PRK remains a rare but potentially devastating complication. Medical records of 3 male patients with infectious keratitis after uneventful PRK for myopia and astigmatism were reviewed retrospectively. PRK was performed using the Wavelight Allegretto excimer laser. Postoperative care included a bandage contact lens (BCL) for 5 days, topical antibiotics, ketorolac, and artificial tears. Keratitis presented 2 - 4 days postoperatively. In one case, each culture was negative (case 1), and was positive for Streptococcus pneumoniae (case 2) and Staphylococcus aureus (case 3). Final BSCVA (best spectacle corrected visual acuity) after intensive antibiotic treatment and removal of BCL were 1.0 (case 1), 0.9 (case 2) and 0.3 correctable to 0.8 with pinhole (case 3). Postoperative broad-spectrum antibiotics are mandatory after PRK to prevent infectious keratitis. However, resistant organisms are more and more common. The presence of a bandage soft contact lens after surgery is an unfavourable element that may increase risk of infection. Based on our case series, we suggest limiting soft contact lens wear during the two postoperative days even if the corneal ulceration is not healed. Copyright Georg Thieme Verlag KG Stuttgart . New York.
In vitro power profiles of daily disposable contact lenses.
Belda-Salmerón, Lurdes; Madrid-Costa, David; Ferrer-Blasco, Teresa; García-Lázaro, Santiago; Montés-Micó, Robert
2013-10-01
To evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles. The Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5mm to 5.5mm in steps of 0.5mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2mm to 1.0mm in steps of 0.2mm). All contact lenses showed an increase - more negative - in lens power with distance from the lens center. The amount of change varied depending on the lens. It was about 10% of lens power for DAILIES TOTAL1 (-0.29diopters (D)), SofLens daily disposable (-0.36D), and Proclear 1-Day (-0.32D) whereas 1-DAY ACUVUE MOIST showed a percentage variation of 3.3% (-0.10D). After inducing a lens decentration up to 1mm, the power curves were shifted in the negative direction. However, the change obtained in lens power compared with well-centered position was always lower than a quarter of diopter both for all the lenses and aperture diameters. Our results showed a variation of the refractive power from the lens center, becoming more negative toward the periphery, with a negligible effect of the decentration for all disposable contact lenses studied. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
The use of contact lens telescopic systems in low vision rehabilitation.
Vincent, Stephen J
2017-06-01
Refracting telescopes are afocal compound optical systems consisting of two lenses that produce an apparent magnification of the retinal image. They are routinely used in visual rehabilitation in the form of monocular or binocular hand held low vision aids, and head or spectacle-mounted devices to improve distance visual acuity, and with slight modifications, to enhance acuity for near and intermediate tasks. Since the advent of ground glass haptic lenses in the 1930's, contact lenses have been employed as a useful refracting element of telescopic systems; primarily as a mobile ocular lens (the eyepiece), that moves with the eye. Telescopes which incorporate a contact lens eyepiece significantly improve the weight, comesis, and field of view compared to traditional spectacle-mounted telescopes, in addition to potential related psycho-social benefits. This review summarises the underlying optics and use of contact lenses to provide telescopic magnification from the era of Descartes, to Dallos, and the present day. The limitations and clinical challenges associated with such devices are discussed, along with the potential future use of reflecting telescopes incorporated within scleral lenses and tactile contact lens systems in low vision rehabilitation. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Oscillatory squeeze film analysis of soft contact lenses.
Donnchadha, Éanna Mac; Leal, Cristina; Esmonde, Harry
2018-04-13
The complex modulus of a soft contact lens affects the optical performance, fitting, on-eye movement, wettability, physiological impact and overall comfort of the lens. However, despite acknowledgement that the mechanical behaviour of contact lenses is time-dependent, the rheological characteristics of contact lenses remain under-defined. While existing studies have focussed on elasticity to describe lens behaviour, this paper proposes using oscillatory squeeze film analysis to evaluate the complex modulus. The effects of excitation amplitude, repeatability and surface wetness are examined for four commercially available lenses. Slip at the lens/platen interface is considered along with bias introduced by pre-compressing the lens between platens. Test results when compared to results reported from other test methods indicate that a high degree of slip occurs at the lens platen interface suggesting that deformation is primarily due to biaxial extension. Copyright © 2018 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Guillon, Michel; Maïssa, Cécile
2010-12-01
The objective of the investigation was to show that, because of their overall properties, Acuvue® Oasys™ with Hydraclear™ Plus brand (senofilcon A) silicone hydrogel contact lenses achieve excellent ocular tissue tolerance during long-term extended wear. The investigation was a 2-year, prospective, extended wear investigation of senofilcon A silicone hydrogel contact lenses worn for up to 6 nights without removal. The 2-year results compared with the subjects' baseline ocular statuses on entering the study revealed: The quantification of the effects on the ocular tissues of 2 years of extended wear of senofilcon A, by mainly previously successful daily soft contact lens wearers, found an excellent biocompatibility. The results support the hypothesis that senofilcon A contact lenses, when worn on a 6-night/7-day extended wear regimen, maintain excellent long-term ocular tissue tolerance. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.
Protein deposition and its effect on bacterial adhesion to contact lenses.
Omali, Negar Babaei; Zhu, Hua; Zhao, Zhenjun; Willcox, Mark D P
2013-06-01
Bacterial adhesion to contact lenses is believed to be the initial step for the development of several adverse reactions that occur during lens wear such as microbial keratitis. This study examined the effect of combinations of proteins on the adhesion of bacteria to contact lenses. Unworn balafilcon A and senofilcon A lenses were soaked in commercially available pure protein mixtures to achieve the same amount of various proteins as found ex vivo. These lenses were then exposed to Pseudomonas aeruginosa and Staphylococcus aureus. Following incubation, the numbers of P. aeruginosa or S. aureus that adhered to the lenses were measured. The possible effect of proteins on bacterial growth was investigated by incubating bacteria in medium containing protein. Although there was a significant (p < 0.003) increase in the total or viable counts of one strain of S. aureus (031) on balafilcon A lenses soaked in the lysozyme/lactoferrin combination, the protein adhered to lenses did not alter the adhesion of any other strains of P. aeruginosa or S. aureus (p > 0.05). Growth of S. aureus 031 (p < 0.0001) but not of P. aeruginosa 6294 was stimulated by addition of lysozyme/lactoferrin combination (2.8/0.5 mg/mL). Addition of lipocalin did not affect the growth of any strains tested (p > 0.05). Adsorption of amounts of lysozyme and lactoferrin or lipocalin equivalent to those extracted from worn contact lenses did not affect the adhesion of most strains of S. aureus or P. aeruginosa to lens surfaces.
Contact Lenses Wettability In Vitro: Effect of Surface-Active Ingredients
Lin, Meng C.; Svitova, Tatyana F.
2010-01-01
Purpose To investigate the release of surface-active agents (surfactants) from unworn soft contact lenses and their influence on the lens surface wettability in vitro. Methods Surface tension (ST) of blister pack solutions was measured by pendant-drop technique. STs at the air-aqueous interface and contact angles (CAs) of four conventional and seven silicone hydrogel (SiH) soft contact lenses (SCLs) were evaluated in a dynamic-cycling regime using a modified captive-bubble tensiometer-goniometer. Measurements were performed immediately after removal from blister packs, and after soaking in a glass vial filled with a surfactant-free solution, which was replaced daily for one week. Lens surface wettability was expressed as adhesion energy (AE) according to Young’s equation. Results STs of all blister pack solutions were lower than the reference ST of pure water (72.5 mN/m), indicating the presence of surfactants. When lenses were depleted of surfactants by soaking, the STs of all studied lenses and advancing CAs of selected lenses increased (p < 0.001). Receding CAs of all studied lenses were 12° ± 5° and were not affected by the presence of surfactants. For most of the conventional lenses, the surface wettability was largely dependent on surfactants, and reduced significantly after surfactant depletion. In contrast, most SiH lenses exhibited stable and self-sustained surface wettability in vitro. Conclusions The manufacturer-added surfactants affected wetting properties of all studied SCLs, although to different degrees. PMID:20400924
Kackar, Siddharth; Suman, Ethel; Kotian, M Shashidhar
2017-01-01
Microbial biofilm formation on contact lenses and lens storage cases may be a risk factor for contact lens-associated corneal infections. Various types of contact lens care solutions are used to reduce microbial growths on lenses. The present study aimed at comparing the growths of biofilms on the different contact lenses and lens cases. The study also aimed at determining the effect of lens care solutions and bacteriophage on these biofilms. One type of hard lens and two types of soft lenses were used for the study. The organisms used were Staphylococcus aureus ATCC 25923, Pseudomonas aeruginosa ATCC 27853, Candida albicans ATCC 60193 and Escherichia coli ATCC 25922. Biofilm production was performed by modified O'Toole and Kolter method and effect of lens cleaning solutions and a crude coliphage on biofilms was also studied. Results were visualised using scanning electron microscopy and quantitated by colony counting method and spectrophotometric measurement of optical density (OD). Statistical analysis was done by SPSS 11.5, Kruskal-Wallis test and Chi-square test. Soft lens cleaning solutions had a significant inhibitory effect (P = 0.020) on biofilm formation on soft lenses and also lens cases (P < 0.001). Soft lens cleaning solution 2 was more efficient than solution 1. However, no such inhibitory effect was observed with regard to hard lens cleaning solution, but for a significant reduction in the OD values (P < 0.001). There was no significant inhibitory effect by bacteriophages. This study showed the importance of selecting the appropriate lens cleaning solution to prevent biofilm production on contact lenses.
Oxygen, water, and sodium chloride transport in soft contact lenses materials.
Gavara, Rafael; Compañ, Vicente
2017-11-01
Oxygen permeability, diffusion coefficient of the sodium ions and water flux and permeability in different conventional hydrogel (Hy) and silicone-hydrogel (Si-Hy) contact lenses have been measured experimentally. The results showed that oxygen permeability and transmissibility requirements of the lens have been addressed through the use of siloxane containing hydrogels. In general, oxygen and sodium chloride permeability values increased with the water content of the lens but there was a percolation phenomenon from a given value of water uptake mainly in the Si-Hy lenses which appeared to be related with the differences between free water and bound water contents. The increase of ion permeability with water content did not follow a unique trend indicating a possible dependence of the chemical structure of the polymer and character ionic and non-ionic of the lens. Indeed, the salt permeability values for silicone hydrogel contact lenses were one order of magnitude below those of conventional hydrogel contact lenses, which can be explained by a diffusion of sodium ions occurring only through the hydrophilic channels. The increase of the ionic permeability in Si-Hy materials may be due to the confinement of ions in nanoscale water channels involving possible decreased degrees of freedom for diffusion of both water and ions. In general, ionic lenses presented values of ionic permeability and diffusivity higher than most non-ionic lenses. The tortuosity of the ionic lenses is lower than the non-ionic Si-Hy lenses. Frequency 55 and PureVision exhibited the highest water permeability and flux values and, these parameters were greater for ionic Si-Hy lenses than for ionic conventional hydrogel lenses. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2218-2231, 2017. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Zhang, Jiyan; Wang, Liru; Ma, Zhenya
2006-11-01
A focimeter is one of the basic ophthalmic instruments used in every optometric practice, and verification of the accuracy and calibration of the instrument are of the utmost importance. For many years the International Standardization for Organization requires that calibrations for all kinds of focimeters shall be accomplished by using test lenses described in ISO 9342:1996. These test lenses must be of high quality and of nominal back vertex power that is known with high accuracy. With the development of science and technology, ISO 9342 was revised in 2005. A new part ISO 9342-2 had been drafted for test lenses used to calibrate focimeters with contact lens measurement, and the original ISO 9342 was turned into the current ISO 9342-1, which could only be used to calibrate fociemters with spectacle lens measurement. As one of the standard drafters, the background for the newly published ISO 9342-2 is introduced in this study, and comparison between test lenses of ISO 9342-1 and ISO 9342-2 is made. Further, the influence of tolerance and uncertainty in design and production of standard test lenses of ISO 9342-2 is analyzed. The paraxial approximation is used to relate the lens parameters with back vertex power and to calculate the uncertainty budget. Moreover, one set of test lenses conforming to ISO 9342-2 is manufactured and experiments are done with it. Results show that test lenses described in ISO 9342-2 can correct the measurement errors of focimeters used for measuring contact lenses well, especially for spherical aberration, and the correction is more effective for spherical contact lenses with high back vertex power.
Delayed Epithelial Closure After PRK Associated With Topical Besifloxacin Use.
Talamo, Jonathan H; Hatch, Kathryn M; Woodcock, Emily C
2013-10-01
To report the observation of prolonged reepithelialization after photorefractive keratectomy (PRK) associated with the use of besifloxacin 0.6% (Besivance; Bausch & Lomb, Rochester, NY) underneath bandage contact lenses (BCLs) placed during surgery. An office-based private practice and retrospective chart review. The healing parameters examined included epithelial healing time, haze formation, discomfort, and visual recovery of 4 patients (7 eyes) treated with besifloxacin 0.6% under BCLs placed after the PRK was performed. All the eyes had delayed epithelial closure (mean, 8.8 days; range 5-13 days). All the patients experienced a delayed visual recovery and significant pain after the surgery, and 2 of 4 patients experienced recurrent corneal erosions for weeks to months after they underwent the PRK. All but 1 eye developed corneal haze persisting for 1 year or more after the surgery. Only 1 eye among the 7 eyes treated with besifloxacin 0.6% under the BCL had 20/20 or better uncorrected visual acuity 3 months postoperatively. All the patients treated with besifloxacin 0.6% on the stromal bed exhibited significant problems with corneal epithelial healing and delayed visual recovery. We caution the use of besifloxacin 0.6% underneath a BCL during a PRK or other ocular surface surgeries requiring corneal epithelial debridement.
... soft contact lenses. You should not use ketorolac eye drops while wearing your soft contact lenses.use caution when driving or operating machinery because your vision may be blurred after you instill the drops.
Quantitation of total protein deposits on contact lenses by means of amino acid analysis.
Yan, G; Nyquist, G; Caldwell, K D; Payor, R; McCraw, E C
1993-04-01
This study was done to characterize and quantify the protein deposits on worn contact lenses and to measure the residual deposits after extraction in 2% sodium dodecyl sulfate and the total protein deposits on worn vifilcon, atlafilcon, and tefilcon lenses (Food and Drug Administration Types IV, II, and I, respectively). Contact lens extracts were separated with gel electrophoresis, and the amount of protein was estimated after silver staining and densitometry. To determine the residual deposits, the contact lenses were hydrolyzed, and amino acid analysis was carried out by reverse-phase high-performance liquid chromatography after precolumn derivatization with phenylisothiocyanate. Refinement of the hydrolysis conditions was undertaken to minimize interference by the lens polymers. The extraction removed only approximately 25% of the protein deposits. Mild hydrolytic conditions, 20 hr in 6 N HCl at 105 degrees C, were found to cause minimal polymer interference. Of the 350, 10, and 20 micrograms of protein typically determined on whole vifilcon, atlafilcon, and tefilcon lenses, the polymers were estimated to account for 4, 0.5, and less than 0.4 micrograms, respectively. Hydrolysis of worn contact lenses with subsequent amino acid separation can be applied to determine the total protein deposits without the uncertainty inherent in extraction of the deposits.
Lievens, Christopher W; Connor, Charles G; Murphy, Heather
2003-10-01
The current study evaluates the response of the ocular surface to extended contact lens wear by comparing a new silicone hydrogel lens to an ACUVUE 2 lens. Twenty subjects with an average age of 28 years were randomly assigned to a fitting with ACUVUE 2 or PureVision lenses. Ocular surface assessment by impression cytology was performed at baseline and for the 6 months after initiation of lens wear. Although goblet cell density significantly increased with wear time, no statistically significant difference was observed between the contact lens groups. The average baseline goblet cell percentages were as follows: ACUVUE 2 group, 1.44; PureVision group, 1.11. The 6-month averages were as follows: ACUVUE 2 group, 3.16; PureVision group, 2.22. It appears that silicone hydrogel lenses may be slightly less irritating to the ocular surface than lenses not containing silicone. This could be a promising indicator for successful 30-day continuous wear.
Quantification of individual proteins in silicone hydrogel contact lens deposits
Zhao, Zhenjun; Zhu, Hua; Tilia, Daniel; Willcox, Mark D.P.
2013-01-01
Purpose The aim of this study was to quantify specific proteins deposited on daily wear silicone hydrogel lenses used in combination with multipurpose disinfecting solutions (MPDSs) by applying multiple-reaction-monitoring mass spectrometry (MRM-MS). Methods Balafilcon A or senofilcon A contact lenses used with different MPDSs on a daily wear schedule were collected. Each worn lens was extracted and then digested with trypsin. MRM-MS was applied to quantify the amounts of lysozyme, lactoferrin, lipocalin-1, proline-rich protein-4, and keratin-1 in the extracts. Results The amount of protein extracted from the contact lenses was affected by the individual wearers, lens material, and type of care system used. Higher amounts of proteins were extracted from lenses after wear when they were used with an MPDS containing polyhexamethylene biguanide (PHMB) and poloxamer 407 compared with MPDSs containing polyquaternium-1 (PQ-1)/alexidine dihydrochloride with Tetronic 904 or PQ-1/ PHMB with poloxamine and sulfobetaine (p<0.05). There was a correlation between the amount of lipocalin-1 or keratin-1 extracted from lenses and symptoms of ocular dryness. Conclusions The MRM-MS technique is a promising approach that could be used to reveal associations of individual proteins deposited on lenses with performance of contact lenses during wear. PMID:23441110
Domínguez-Vicent, Alberto; Esteve-Taboada, Jose Juan; Recchioni, Alberto; Brautaset, Rune
2018-05-01
To assess the power profile and in vitro optical quality of scleral contact lenses with different powers as a function of the optical aperture. The mini and semiscleral contact lenses (Procornea) were measured for five powers per design. The NIMO TR-1504 (Lambda-X) was used to assess the power profile and Zernike coefficients of each contact lens. Ten measurements per lens were taken at 3- and 6-mm apertures. Furthermore, the optical quality of each lens was described in Zernike coefficients, modulation transfer function, and point spread function (PSF). A convolution of each lens PSF with an eye-chart image was also computed. The optical power fluctuated less than 0.5 diopters (D) along the optical zone of each lens. However, the optical power obtained for some lenses did not match with its corresponding nominal one, the maximum difference being 0.5 D. In optical quality, small differences were obtained among all lenses within the same design. Although significant differences were obtained among lenses (P<0.05), these showed small impact in the image quality of each convolution. Insignificant power fluctuations were obtained along the optical zone measured for each scleral lens. Additionally, the optical quality of both lenses has showed to be independent of the lens power within the same aperture.
Lathe-cut hydrophilic contact lenses: report of 100 clinical cases.
Espy, J W
1978-10-01
In a review of the literature, it became apparent that there were very few articles describing the advantages, as well as the fitting techniques, of lathe-cut hydrophilic contact lenses. Few practitioners, including those who fit other types of hydrophilic lenses and hard lenses, have had any experience with this lens, and considerable interest has been generated by fragmentary reports of good results. This paper describes in detail the geometry of the first lathe-cut hydrophilic lens approved by the Federal Drug Administration, the fitting methods utilizing trial lenses, and the results of 100 patients successfully fitted.
Pseudomonas aeruginosa Survival at Posterior Contact Lens Surfaces after Daily Wear
Wu, Yvonne T.; Zhu, Lucia S.; Tam, K. P. Connie; Evans, David J.; Fleiszig, Suzanne M. J.
2015-01-01
Purpose Pseudomonas aeruginosa keratitis is a sight-threatening complication of contact lens wear, yet mechanisms by which lenses predispose to infection remain unclear. Here, we tested the hypothesis that tear fluid at the posterior contact lens surface can lose antimicrobial activity over time during lens wear. Methods Daily disposable lenses were worn for 1, 2, 4, 6 or 8 h immediately after removal from their packaging, or after presoaking in sterile saline for 2 days to remove packaging solution. Unworn lenses were also tested, some coated in tears “aged” in vitro for 1 or 8 h. Lenses were placed anterior surface down into tryptic soy agar cradles containing gentamicin (100µg/ml) to kill bacteria already on the lens, and posterior surfaces inoculated with gentamicin-resistant P. aeruginosa for 3 h. Surviving bacteria were enumerated by viable counts of lens homogenates. Results Posterior surfaces of lenses worn by patients for 8 h supported more P. aeruginosa growth than lenses worn for only 1 h, if lenses were presoaked prior to wear (~ 2.4-fold, p = 0.01). This increase was offset if lenses were not presoaked to remove packaging solution (p = 0.04 at 2 h and 4 h). Irrespective of presoaking, lenses worn for 8 h showed more growth on their posterior surface than unworn lenses coated with tear fluid that was “aged” for 8 h vitro (~8.6-fold, presoaked, p = 0.003: ~ 5.4-fold from packaging solution, p = 0.004). Indeed, in vitro incubation did not impact tear antimicrobial activity. Conclusions This study shows that post lens tear fluid can lose antimicrobial activity over time during contact lens wear, supporting the idea that efficient tear exchange under a lens is critical for homeostasis. Additional studies are needed to determine applicability to other lens types, wearing modalities, and relevance to contact lens-related infections. PMID:25955639
Peripheral optics with bifocal soft and corneal reshaping contact lenses.
Ticak, Anita; Walline, Jeffrey J
2013-01-01
To determine whether bifocal soft contact lenses with a distance center design provide myopic defocus to the peripheral retina similar to corneal reshaping contact lenses. Myopic subjects underwent five cycloplegic autorefraction readings centrally and at 10, 20, and 30 degrees temporally, nasally, superiorly, and inferiorly while wearing Proclear Multifocal "D" contact lenses with a +2.00-diopter add power (CooperVision, Fairport, NY) and after wearing Corneal Refractive Therapy (Paragon Vision Sciences, Mesa, AZ) contact lenses for 2 weeks. Fourteen subjects completed the study. Nine (64%) were female, and 12 (86%) were white. The average (± SD) spherical equivalent noncycloplegic manifest refraction for the right eye was -2.84 ± 1.29 diopters. The average logMAR best-corrected, binocular, high-contrast visual acuity was -0.17 ± 0.15 while wearing the bifocal soft contact lenses and -0.09 ± 0.16 after corneal reshaping contact lens wear (analysis of variance, p = 0.27). The orthokeratology contact lens yielded a more myopic peripheral optical profile than the soft bifocal contact lens at 20 and 30 degrees eccentricity (except inferior at 20 degrees); the two modalities were similar at 10 degrees eccentricity. Our data suggest that the two modalities are dissimilar despite the statistical similarities. The corneal reshaping contact lens shows an increase in relative peripheral myopic refraction, a pattern achieved by other studies, but the bifocal lens does not exhibit such a pattern. The low statistical power of the study could be a reason for lack of providing statistical difference in other positions of gaze, but the graphical representation of the data shows a marked difference in the peripheral optical profile between the two modalities. More sophisticated methods of measuring the peripheral optical profile may be necessary to accurately compare the two modalities and to determine the true optical effect of the bifocal soft contact lens on the peripheral retina.
... purpose is to determine whether you have a refractive error (a need for glasses or contact lenses). For ... glasses or contact lenses) is normal, then the refractive error is zero (plano) and your vision should be ...
Corneal Biomechanical Changes Following Toric Soft Contact Lens Wear.
Radaie-Moghadam, Somayeh; Hashemi, Hassan; Jafarzadehpur, Ebrahim; Yekta, Abbas Ali; Khabazkhoob, Mehdi
2016-01-01
To determine the effect of using toric soft contact lenses on corneal biomechanical properties. We enrolled 33 healthy patients with mean age of 23.18 ± 4.06 and minimal cylinder power of 1 D (-1.98 ± 0.808 SD) and negative history of contact lens use; keratoconic patients were excluded from the study. Toric soft contact lenses (BIOFINITY, Comfilcon A, Coopervision, Southampton, UK) were fitted in all participants. The Ocular Response Analyzer (Reichert Ophthalmic Instruments, Depew, New York, USA) was used to measure corneal hysteresis (CH), corneal resistance factor (CRF), and the Pentacam HR (Oculus, Inc., Lynnwood, WA, USA) was used to measure central corneal thickness (CCT) and mean keratometry (K mean) before and one week, one month, and three months after using the toric soft contact lenses. CH and CRF were decreased significantly one month after using the contact lens; mean CH decreased from 9.99 ± 1.44 to 9.59 ± 1.54 mmHg, and mean CRF decreased from 9.96 ± 1.71 to 9.63 ± 1.73 mmHg (P = 0.013 and P = 0.017, respectively). Mean CCT and K mean did not show a significant change during the period of toric soft contact lens use. CH and CRF decreased significantly one month after fitting toric soft contact lenses while CCT and Kmean did not change significantly. Corneal biomechanical parameters may alter with toric soft contact lens use and such changes may have implications with long-term use such lenses.
Harimoto, Kouzo; Kato, Naoko; Shoji, Takuhei; Goto, Hiroya; Tokuno, Shinichi; Fujii, Manabu; Takeuchi, Masaru
2014-02-01
To investigate the trends in refractive correction in Japanese Ground Self-Defense Forces' (JGSDF) soldiers. A questionnaire was distributed to 519 soldiers of the Camp Funaoka in the northeastern region. Five hundred and sixteen subjects (99.4%) responded. In total, 246 soldiers (47.7%) wore spectacles or contact lenses. Among the contact lens wearers, 52 had experienced problems previously and 35 reported problems that occurred during military exercises. With regard to military exercises, 66.9% and 63.5% of the spectacle or disposable soft contact lens-users reported inconvenience. Among contact lens users, 33.1% reported that they changed to new sterilized contact lenses only occasionally and 61.9% did not change their contact lenses at all during exercises. During disaster-relief work, subjects worried 'very' (21.5%) or 'somewhat' (46.9%) about problems associated with their spectacles or contact lenses. Twenty-four had undergone refractive surgery (4.9%). About one-half of the JGSDF soldiers surveyed required refractive correction. Attention to convenient and safe refractive correction in the military is warranted.
Pseudomonas keratitis associated with daily wear of silicone hydrogel contact lenses.
Schornack, Muriel M; Faia, Lisa J; Griepentrog, Gregory J
2008-03-01
To report two cases of pseudomonas keratitis associated with daily wear of silicone hydrogel contact lenses. Medical records of two patients who developed pseudomonas keratitis while wearing silicone hydrogel lenses on a daily-wear schedule are reviewed and discussed. A 13-year-old girl who wore ACUVUE Advance lenses (Johnson & Johnson Vision Care, Jacksonville, FL) 12 to 14 hours daily developed a paracentral corneal ulcer in her left eye 4 months after beginning contact lens use. Cultures were positive for Pseudomonas aeruginosa. The ulcer responded to fortified antibiotics and resolved in 10 days. Best-corrected visual acuity after resolution of the ulcer was 20/25. A 58-year-old woman with a 30-year history of rigid gas-permeable contact lens wear was refitted with O2 Optix lenses (CIBA Vision, Duluth, GA). Six months later, she had a 4.9 x 4.0 mm epithelial defect with an underlying stromal infiltrate in the right eye. Cultures were positive for P. aeruginosa. The ulcer responded to fortified antibiotics and resolved in 30 days. Best-corrected visual acuity after resolution of the ulcer was 20/30. Increased oxygen permeability associated with silicone hydrogel contact lenses may reduce, but does not eliminate, the risk of pseudomonas keratitis. Studies have yet to quantify the risk of keratitis associated with daily wear of these lens materials. Further study is necessary to identify the risks of complications with daily wear of silicone hydrogel lenses and to determine which factors may contribute to those risks.
NASA Astrophysics Data System (ADS)
Ben Yaish, Shai; Zlotnik, Alex; Raveh, Ido; Yehezkel, Oren; Belkin, Michael; Lahav, Karen; Zalevsky, Zeev
2009-02-01
We present novel technology for extension in depth of focus of imaging lenses for use in ophthalmic lenses correcting myopia, hyperopia with regular/irregular astigmatism and presbyopia. This technology produces continuous focus without appreciable loss of energy. It is incorporated as a coating or engraving on the surface for spectacles, contact or intraocular lenses. It was fabricated and tested in simulations and in clinical trials. From the various testing this technology seems to provide a satisfactory single-lens solution. Obtained performance is apparently better than those of existing multi/bifocal lenses and it is modular enough to provide solution to various ophthalmic applications.
Phospholipids and their degrading enzyme in the tears of soft contact lens wearers.
Yamada, Masakazu; Mochizuki, Hiroshi; Kawashima, Motoko; Hata, Seiichiro
2006-12-01
Low tear phospholipids levels are associated with tear film instability in soft contact lens wearers. We assayed levels of phospholipids and their degrading enzyme secretory phospholipase A2 (sPLA2) both in tears and deposited on contact lenses composed of 2 hydrophilic materials after 1 day of routine use. Polymacon (Medalist; FDA group 1, low water/nonionic) and Etafilcon A (One Day Acuvue; group 4, high water/ionic) contact lenses were worn for 12 hours by 16 experienced contact lens wearers. Phospholipids in tear fluids and deposited on contact lenses were estimated by phosphorus determination with ammonium molybdate through enzymatic digestion. Double-antibody sandwich ELISA was used to determine group IIa sPLA2 concentrations, and sPLA2 activity was assayed using 1,2-diheptanoyl thio-phosphatidylcholine as substrate. Phospholipids concentrations in tears with Polymacon and Etafilcon A were 186 +/- 39 and 162 +/- 33 microg/mL, respectively. The latter concentration was significantly lower than that observed in the same subjects when not wearing contact lenses (P = 0.0023). In tears, both group IIa sPLA2 concentrations and enzymatic activity remained unchanged, regardless of lens wearing. However, Etafilcon A (0.57 +/- 0.09 microg/lens) showed more group IIa sPLA2 deposition than Polymacon (0.01 +/- 0.01 microg/lens; P < 0.001). Furthermore, group IIa sPLA2 deposited on Etafilcon A but not on Polymacon lenses retained its enzymatic activity. Significant differences of group IIa sPLA2 deposition were found in the 2 lenses tested. Such deposition might induce phospholipid hydrolysis in tears and thereby promote tear film instability in hydrophilic contact lens wearers.
Comfort, Ocular Dryness, and Equilibrium Water Content Changes of Daily Disposable Contact Lenses.
Insua Pereira, Eduardo; Lira, Madalena
2017-10-26
The objective of this investigation was to evaluate the level of comfort and ocular dryness during wear with six daily disposable contact lenses (DDCL) and also determine the changes in contact lens equilibrium water content (EWC) resulting from their wear. In this contralateral open trial, 27 subjects were randomly fitted with six DDCL (stenfilcon A, delefilcon A, nelfilcon A, narafilcon A, nesofilcon A, and omafilcon A). The evaluation of comfort and ocular dryness sensation was recorded by the participants at two moments of the day (11 AM and 5 PM) over a period of 10 days of contact lens wear. The assessment was made with the aid of visual analogue scales (0-10). The refractive index of 54 contact lenses was accessed by a single operator using a digital automated refractometer (CLR 12-70; Index Instruments). The EWC of the lenses was estimated based on its refractive index values. Comfort ratings were slightly higher for delefilcon A (9.56±0.67, P=0.01) and narafilcon A (9.40±0.93, P=0.01) and these lenses wearers also reported less ocular dryness. The results revealed a pronounced water content reduction for omafilcon A (P=0.002), narafilcon A (P=0.008), and nesofilcon A (P=0.003). Although changes in subjective responses and EWC were distinct among the materials analyzed, all the contact lenses performed well during the 10 days of wear.
Sankaridurg, P R; Willcox, M D; Sharma, S; Gopinathan, U; Janakiraman, D; Hickson, S; Vuppala, N; Sweeney, D F; Rao, G N; Holden, B A
1996-01-01
Ten episodes of adverse responses to contact lens wear, including contact lens-induced acute red eye (CLARE), in which Haemophilus influenzae was isolated from contact lenses and/or from one of the external ocular sites at the time of the event, are described. All episodes occurred in patients wearing disposable hydrogel lenses on a 6-night extended-wear schedule. Two of the patients had recurrent episodes. H. influenzae was usually isolated in large numbers, and other bacteria or fungi colonizing the contact lens or the external ocular surface were usually present in low numbers. Those patients who were colonized with H. influenzae were more than 100 times as likely to have had a CLARE or infiltrative response than those subjects who were not colonized with this bacterium. H. influenzae colonization of the contact lens and eye may be subsequent to colonization of the nasopharynx because four of the seven patients presented with fever at the time of the event, with concurrent upper respiratory tract infection. Contact lens wearers should be made aware of the potential risk of CLARE associated with the wearing of contact lenses for extended periods during and subsequent to upper respiratory tract infection. PMID:8880493
Rad, Maryam Shayani; Mohajeri, Seyed Ahmad
2016-09-01
The purpose of the present study was to evaluate the efficacy of commercial soft contact lenses, loaded with vitamin E, as ocular drug delivery systems for simultaneous loading and release of ciprofloxacin (Cipro) and betamethasone (BMZ) in artificial tears. In this study, we applied vitamin E as a barrier to increase BMZ-Cipro loading into three commercial silicone-based soft contact lenses and control their simultaneous release into the artificial lachrymal fluid. Two different concentrations of vitamin E solution (0.1 and 0.2 g/ml) were used, and various parameters including changes in lens diameter, water content, ultraviolet-visible light (UV-Vis) transmittance, drug-binding properties, and drug release profile were investigated. The obtained results indicated that vitamin E significantly reduced the swelling properties of contact lenses in aqueous media, while it enhanced the lens diameter in both dry and hydrated states. Vitamin E had no significant effects on visible transmittance, while it blocked UV radiation, which could be harmful for the eye surface. Our findings revealed that vitamin E improved the simultaneous loading amount of BMZ-Cipro into soft contact lenses. Additionally, BMZ and Cipro release rates significantly reduced after using vitamin E as a hydrophobic diffusion barrier. After soaking the lenses in 0.1 and 0.2 g/ml of vitamin E solution, BMZ release time increased by 28.8-81.6 and 182.4-201 folds, respectively. Moreover, Cipro release time increased by 12-18 and 1152-2313 folds, respectively. The results of the present study indicated the efficacy of vitamin E as a diffusion barrier in developing a controlled drug delivery system for the simultaneous loading of BMZ and Cipro and sustaining their release from soft contact lenses.
Iskeleli, Güzin; Bahar, Hrisi; Eroglu, Ebru; Torun, Muzeyyen Mamal; Ozkan, Sehirbay
2005-05-01
To determine the effect of 30-day continuous-wear silicone hydrogel contact lenses on the conjunctival flora in asymptomatic wearers. The authors studied 29 eyes of 15 patients wearing Focus NIGHT & DAY silicone hydrogel contact lenses for up to 30 nights of continuous wear. The average age of the patients was 25.54 +/- 8.98 years. Cultures of the inferior cul-de-sac were taken bilaterally from all eyes, before and after lens wear in asymptomatic patients. The isolation and identification of bacteria were made by standard clinical laboratory methods. The number of eyes whose conjunctival cultures were sterile before using the lenses significantly decreased (P = 0.0005), and the number of eyes with a growth of coagulase-negative staphylococci and diphtheroid rods in their conjunctival cultures significantly increased after using these lenses (P = 0.001 and P = 0.031, respectively). Conversely, a statistically significant difference was not found in the number of eyes that carried Propionibacterium acnes and Fusobacterium nucleatum in their conjunctival cultures before and after using the 30-day continuous-wear silicone hydrogel lenses (P = 0.998 and P = 0.488, respectively). The results suggest that the sterility of the conjunctiva significantly decreased after using 30-day continuous-wear silicone hydrogel contact lenses. In addition, the number of bacteria of the normal conjunctival flora significantly increased after the use of these lenses. Contamination by the bacteria of the eyelids may be a possible colonization factor in this study group. Therefore, it is appropriate to examine the patients who wear these lenses more frequently.
Diamond Nanogel-Embedded Contact Lenses Mediate Lysozyme-Dependent Therapeutic Release
2015-01-01
Temporarily implanted devices, such as drug-loaded contact lenses, are emerging as the preferred treatment method for ocular diseases like glaucoma. Localizing the delivery of glaucoma drugs, such as timolol maleate (TM), can minimize adverse effects caused by systemic administration. Although eye drops and drug-soaked lenses allow for local treatment, their utility is limited by burst release and a lack of sustained therapeutic delivery. Additionally, wet transportation and storage of drug-soaked lenses result in drug loss due to elution from the lenses. Here we present a nanodiamond (ND)-embedded contact lens capable of lysozyme-triggered release of TM for sustained therapy. We find that ND-embedded lenses composed of enzyme-cleavable polymers allow for controlled and sustained release of TM in the presence of lysozyme. Retention of drug activity is verified in primary human trabecular meshwork cells. These results demonstrate the translational potential of an ND-embedded lens capable of drug sequestration and enzyme activation. PMID:24506583
Impact of multilayered compression bandages on sub-bandage interface pressure: a model.
Al Khaburi, J; Nelson, E A; Hutchinson, J; Dehghani-Sanij, A A
2011-03-01
Multi-component medical compression bandages are widely used to treat venous leg ulcers. The sub-bandage interface pressures induced by individual components of the multi-component compression bandage systems are not always simply additive. Current models to explain compression bandage performance do not take account of the increase in leg circumference when each bandage is applied, and this may account for the difference between predicted and actual pressures. To calculate the interface pressure when a multi-component compression bandage system is applied to a leg. Use thick wall cylinder theory to estimate the sub-bandage pressure over the leg when a multi-component compression bandage is applied to a leg. A mathematical model was developed based on thick cylinder theory to include bandage thickness in the calculation of the interface pressure in multi-component compression systems. In multi-component compression systems, the interface pressure corresponds to the sum of the pressures applied by individual bandage layers. However, the change in the limb diameter caused by additional bandage layers should be considered in the calculation. Adding the interface pressure produced by single components without considering the bandage thickness will result in an overestimate of the overall interface pressure produced by the multi-component compression systems. At the ankle (circumference 25 cm) this error can be 19.2% or even more in the case of four components bandaging systems. Bandage thickness should be considered when calculating the pressure applied using multi-component compression systems.
Lee, Ga-Hyun; Yu, Hak-Sun; Lee, Ji-Eun
2016-03-01
To evaluate the effect of multipurpose contact lens care solutions (MPSs) on the adhesion of Acanthamoeba to rigid gas permeable (RGP) contact lenses. Acanthamoeba castellanii (AC) trophozoites were inoculated onto untreated RGP contact lenses (FP, Extra, or Menicon Z), and numbers of trophozoites adhering to lenses were counted under a phase contrast microscope at 18 h post-inoculation (controls). Similarly, adhering trophozoites were counted at 6 h post-inoculation on each of the three RGP lens types with one of three MPSs (Boston Simplus, Menicare Plus, and O2 Care). Scanning electron microscopic examinations were performed to compare lens surfaces. Adhesion of AC trophozoites to untreated FP was greater than to untreated Extra or Menicon Z. Surfaces of Extra and Menicon Z lenses were waxier, smoother, and more homogeneous than those of FP lenses. After treatment with Boston Simplus, adhesion of AC trophozoites was significantly reduced for all lens types as compared with controls (p < 0.0001). Treatments with Menicare Plus or O2 Care reduced the number of adherent AC trophozoites significantly on FP lenses only as compared with controls (p < 0.0001). The adhesion rates of AC trophozoites to RGP lenses depended on lens surfaces. Boston Simplus reduced the adhesion rate of AC trophozoites more than Menicare Plus or O2 Care. Appropriate RGP lens and MPS selection could decrease the prevalence of Acanthamoeba keratitis. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.
Kim, Eon; Bakaraju, Ravi C; Ehrmann, Klaus
2016-01-01
To evaluate the repeatability of power profiles measured on NIMO TR1504 (Lambda-X, Belgium) and investigate the effects of lens decentration on the power profiles for single vision (SV), bifocal (BF) and multifocal (MF) contact lenses. Accuracy of the sphere power was evaluated using single vision BK-7 calibration glass lenses of six minus and six plus powers. Three SV and four BF/MF contact lenses - three lenses each, were measured five times to calculate the coefficients of repeatability (COR) of the instrument. The COR was computed for each chord position, lens design, prescription power and operator. One lens from each type was measured with a deliberate decentration up to ±0.5mm in 0.1mm steps. For all lenses, the COR varied across different regions of the half-chord position. In general, SV lenses showed lower COR compared to the BF/MF group lenses. There were no noticeable trends of COR between prescription powers for SV and BF/MF lenses. The shape of the power profiles was not affected when lenses were deliberately decentered for all SV and PureVision MF lenses. However, for Acuvue BF lenses, the peak to trough amplitude of the power profiles flattened up to 1.00D. The COR across the half-chord of the optic zone diameter was mostly within clinical relevance except for the central 0.5mm half-chord position. COR were dependent on the lens type, whereby BF/MF group produced higher COR than SV lenses. The effects of deliberate decentration on the shape of power profiles were pronounced for lenses where the profiles had sharp transitions of power. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Shayani Rad, Maryam; Mohajeri, Seyed Ahmad
2017-03-01
Ciprofloxacin (Cipro) is an antibiotic, widely used in form of ophthalmic drops (0.3%) for the treatment of eye infections. In this study, vitamin E was used as a hydrophobic barrier to improve and prolong the amount and time of Cipro release from silicone-based soft contact lenses. Three different commercial contact lenses (Air Optix, Biofinity, and Acuvue Oasys) were soaked in vitamin E solutions (0.1 and 0.2 g/mL). The effect of vitamin E on Cipro loading amount and drug releasing profile was evaluated in artificial tear. Swelling properties and diameter changes of the lenses were also investigated in aqueous media in presence and absence of vitamin E. The data indicated that vitamin E, as a hydrophobic barrier, significantly decreased the water content of silicone-based soft contact lenses. After vitamin E loading, a 5% to 18% increase was observed in lens diameter in the hydrated state, whereas the lens diameter increased by 11% to 23% in the dry state. In all commercial lenses, vitamin E loading in a 0.2-g/mL solution caused a 27.94% to 37.08% increase in Cipro binding. The results indicated that applying vitamin E loading solutions, with 0.1 and 0.2 g/mL concentrations, could effectively enhance Cipro release time from 2 hr (in a pure non-vitamin E-loaded lens) to 14 to 17 and 30 to 33 days, respectively. These values showed an increase by a factor of 168 to 204 and 360 to 396 in Cipro release time after using vitamin E loading solutions with 0.1 and 0.2 g/mL concentrations, respectively, compared with pure non-vitamin E-loaded soft contact lenses. This study indicated that vitamin E acts as an effective hydrophobic barrier, in increasing the Cipro loading capacity of silicone-based contact lenses and prolonging the drug release into the artificial tear.
... e.g., use sunglasses). Cyclopentolate may make your eyes sensitive to sunlight.you should know that ophthalmic cyclopentolate contains benzalkonium chloride, which can be absorbed by soft contact lenses. If you wear contact lenses, remove them before instilling ophthalmic cyclopentolate.
Focusing on Contact Lens Safety
... lenses to FDA’s MedWatch reporting program . How to Report Problems Here’s how you can help: If you ... selling contact lenses over the Web, you should report it to the FDA . If you don’t ...
Colored cosmetic contact lenses: an unsafe trend in the younger generation.
Singh, Shwetambari; Satani, Dipali; Patel, Amit; Vhankade, Ravinder
2012-07-01
To identify the microbiological profile and evaluate the clinical course and outcomes in patients who developed severe infectious keratitis after colored cosmetic contact lens wear. This case series includes 13 patients who developed severe infectious keratitis after colored cosmetic contact lens wear. A detailed history regarding contact lens availability and storage and handling techniques was taken. All patients underwent standard diagnostic microbiological evaluation followed by culture-guided topical antimicrobial therapy. Of 13 patients, 8 were male and 5 were female, with mean age at presentation of 19 ± 3.8 years. All patients were emmetropic, and lenses were worn solely for cosmetic purposes. Seven lenses were dispensed without prescription or fitting from an unlicensed optical shop, 5 patients had shared lenses with friends/relatives, and 1 patient obtained the lens from the garbage. None of the patients followed the recommended contact lens handling and storage techniques. The causative microorganisms included Pseudomonas aeruginosa (54%), Staphylococcus aureus (25%), and Staphylococcus epidermidis (17%), with 1 case of viral keratitis. In 62% of cases, ulcer size was ≥5 × 5 mm and posttreatment corrected visual acuity was 6/24 or less. All patients responded well to topical antimicrobials, and none required surgical intervention. Over-the-counter use of decorative lenses as a cosmetic aid is rapidly increasing. Easy and unmonitored availability of these cosmetic lenses is followed by severe sight-threatening complications in young emmetropic individuals.
Guillon, Michel; Maïssa, Cécile
2010-12-01
The objective of the investigation was to show that, because of their overall properties, Acuvue® Oasys™ with Hydraclear® Plus brand (senofilcon A) silicone hydrogel contact lenses achieve excellent ocular tissue tolerance during long-term daily wear. The 2-year investigation was a prospective daily wear analysis of Acuvue® Oasys™ with Hydraclear® Plus (senofilcon A) silicone hydrogel contact lenses replaced every 2 weeks and used in conjunction with a representative range of care systems. The 2-year results compared with the subjects' baseline ocular status on entering the study revealed: The quantification of the effects on the ocular tissues of 2 years of daily wear of senofilcon A, by mainly previously successful daily soft contact lens wearers, showed an excellent biocompatibility. The results support the hypothesis that senofilcon A contact lenses, when worn on a 2-week daily wear regimen, maintain excellent long-term ocular tissue tolerance. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.
Acanthamoeba keratitis in patients wearing scleral contact lenses.
Sticca, Matheus Porto; Carrijo-Carvalho, Linda C; Silva, Isa M B; Vieira, Luiz A; Souza, Luciene B; Junior, Rubens Belfort; Carvalho, Fábio Ramos S; Freitas, Denise
2018-06-01
To report a series of cases of Acanthamoeba keratitis (AK) in scleral lens wearers with keratoconus to determine whether this type of contact lens presents a greater risk for development of infection. This study reports three patients who wore scleral contact lenses to correct keratoconus and developed AK. The diagnoses of AK were established based on cultures of the cornea, scleral contact lenses, and contact lens paraphernalia. This study investigated the risk factors for infections. The possible risks for AK in scleral contact lens wearers are hypoxic changes in the corneal epithelium because of the large diameter and minimal tear exchange, use of large amounts of saline solution necessary for scleral lens fitting, storing the scleral lens overnight in saline solution rather than contact lens multipurpose solutions, not rubbing the contact lens during cleaning, and the space between the cornea and the back surface of the scleral lens that might serve as a fluid reservoir and environment for Acanthamoeba multiplication. Two patients responded well to medical treatment of AK; one is still being treated. The recommendations for use and care of scleral contact lenses should be emphasized, especially regarding use of sterile saline (preferably single use), attention to rubbing the lens during cleaning, cleaning of the plunger, and overnight storage in fresh contact lens multipurpose solutions without topping off the lens solution in the case. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Cui, Lele; Chen, Sisi; Zhou, Weihe; Sheng, Kaixuan; Zhang, Lei; Shen, Meixiao; Li, Ming
2018-01-01
To determine conjunctival overlap over the edge of soft contact lens and to visualize the peripheral postlens tear film (PoLTF) underneath soft contact lenses using ultrahigh-resolution optical coherence tomography (UHR-OCT). Twenty participants (4 males and 16 females, 23.0 ± 3.7 years) were fitted with two different types of soft contact lenses randomly. The limbus with lens was imaged with the UHR-OCT at the horizontal meridian every two hours up to 6 hours during lens wear. The conjunctival overlap was ranked as the percentage of the edge covered by the conjunctiva. The frequency of occurrence for visualized peripheral PoLTF was determined. The average conjunctival overlaps at insertion were 49% and 73% for galyfilcon A and balafilcon A lenses and increased significantly to 84% and 90% by 6 hours of lens wear ( P < 0.001). Lenses with rounded edges had more conjunctival overlap than the lenses with angled edges ( P =0.014). There were significant decreases for PoLTF on the conjunctiva ( P =0.014) and peripheral cornea ( P =0.004) over the study period compared to insertion. The percentage of subjects with PoLTF on the conjunctiva (32.5%) and peripheral cornea (36%) were greater in subjects wearing balafilcon A lenses ( P =0.017). Increased conjunctival overlap over the lens edges and reduced PoLTF underneath the peripheral region of soft contact lenses were shown during lens daily wear. The lens edge configuration may play a role in conjunctival response and peripheral PoLTF.
Schürer, M; Walter, A; Brünner, H; Langenbucher, A
2015-08-01
Colored transparent filters cause a change in color perception and have an impact on the perceptible amount of different colors and especially on the ability to discriminate between them. Yellow or orange tinted contact lenses worn to enhance contrast vision by reducing or blocking short wavelengths also have an effect on color perception. The impact of the yellow and orange tinted contact lenses Wöhlk SPORT CONTRAST on color discrimination was investigated with the Erlangen colour measurement system in a study with 14 and 16 subjects, respectively. In relation to a yellow reference color located at u' = 0.2487/v' = 0.5433, measurements of color discrimination thresholds were taken in up to 6 different color coordinate axes. Based on these thresholds, color discrimination ellipses were calculated. These results are given in the Derrington, Krauskopf and Lennie (DKL) color system. Both contact lenses caused a shift of the reference color towards higher saturated colors. Color discrimination ability with the yellow and orange colored lenses was significantly enhanced along the blue-yellow axis in comparison to the reference measurements without a tinted filter. Along the red-green axis only the orange lens caused a significant reduction of color discrimination threshold distance to the reference color. Yellow and orange tinted contact lenses enhance the ability of color discrimination. If the transmission spectra and the induced changes are taken into account, these results can also be applied to other filter media, such as blue filter intraocular lenses.
The use of contact lenses in the civil airman population.
DOT National Transportation Integrated Search
1990-09-01
Federal Aviation Regulations permit the routine use of contact lenses by civilian pilots to satisfy the distant visual acuity requirements for obtaining medical certificates. Specific information identifying the prevalence of both defective distant v...
Contact Lenses for Color Blindness.
Badawy, Abdel-Rahman; Hassan, Muhammad Umair; Elsherif, Mohamed; Ahmed, Zubair; Yetisen, Ali K; Butt, Haider
2018-06-01
Color vision deficiency (color blindness) is an inherited genetic ocular disorder. While no cure for this disorder currently exists, several methods can be used to increase the color perception of those affected. One such method is the use of color filtering glasses which are based on Bragg filters. While these glasses are effective, they are high cost, bulky, and incompatible with other vision correction eyeglasses. In this work, a rhodamine derivative is incorporated in commercial contact lenses to filter out the specific wavelength bands (≈545-575 nm) to correct color vision blindness. The biocompatibility assessment of the dyed contact lenses in human corneal fibroblasts and human corneal epithelial cells shows no toxicity and cell viability remains at 99% after 72 h. This study demonstrates the potential of the dyed contact lenses in wavelength filtering and color vision deficiency management. © 2018 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Coral-Ghanem, Cleusa; Alves, Milton Ruiz
2008-01-01
To evaluate the clinical performance of Monocurve and Bicurve (Soper-McGuire design) rigid gas-permeable contact lens fitting in patients with keratoconus. A prospective and randomized comparative clinical trial was conducted with a minimum follow-up of six months in two groups of 63 patients. One group was fitted with Monocurve contact lenses and the other with Bicurve Soper-McGuire design. Study variables included fluoresceinic pattern of lens-to-cornea fitting relationship, location and morphology of the cone, presence and degree of punctate keratitis and other corneal surface alterations, topographic changes, visual acuity for distance corrected with contact lenses and survival analysis for remaining with the same contact lens design during the study. During the follow-up there was a decrease in the number of eyes with advanced and central cones fitted with Monocurve lenses, and an increase in those fitted with Soper-McGuire design. In the Monocurve group, a flattening of both the steepest and the flattest keratometric curve was observed. In the Soper-McGuire group, a steepening of the flattest keratometric curve and a flattening of the steepest keratometric curve were observed. There was a decrease in best-corrected visual acuity with contact lens in the Monocurve group. Survival analysis for the Monocurve lens was 60.32% and for the Soper-McGuire was 71.43% at a mean follow-up of six months. This study showed that due to the changes observed in corneal topography, the same contact lens design did not provide an ideal fitting for all patients during the follow-up period. The Soper-McGuire lenses had a better performance than the Monocurve lenses in advanced and central keratoconus.
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-01-01
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses. PMID:28447604
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics.
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-04-27
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
NASA Astrophysics Data System (ADS)
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-04-01
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.
Ogbuehi, Kelechi C
2012-06-01
To quantify the influence of soft contact lens power and thickness on the intraocular pressure (IOP). Thirty-nine young, healthy adult volunteers completed this study. One eye of each subject was randomly assigned either a +6D or a -6D high water content daily disposable lens. The other eye was fitted with the second lens. Triplicate measurements of IOP were taken before, during, and after contact lens wear. Each time, IOP was assessed in a randomized order with two noncontact tonometers. The lenses were swapped between eyes during a second session of measurements, one week later. In the first session with the +6D lenses, the average IOPs (±SDs) before, with the lenses fitted, and after the lenses were removed, were: 14.3 ± 2.9 mmHg, 17.0 ± 3.3 mmHg and 13.9 ± 3.1 mmHg, respectively, for the CT80 and 13.6 ± 3.1 mmHg, 17.1 ± 4.5 mmHg and 13.3 ± 2.9 mmHg, respectively, for the PT100. The corresponding values for the first session with the -6D lenses were: 14.3 ± 3.1 mmHg, 13.1 ± 3.1 mmHg and 14.1 ± 3.3 mmHg, respectively, for the CT80 and 13.6 ± 3.2 mmHg, 13.0 ± 3.0 mmHg and 13.6 ± 3.2 mmHg, respectively, for the PT100. IOP significantly (P<0.05) increased (+ΔIOP=2.7 ± 0.4 mmHg with the CT80 in the first session) with the +6D lenses, but decreased (P<0.05) when the -6D lenses were fitted (-ΔIOP=0.6 ± 0.2 mmHg with the PT100 in the first session). The soft contact lens-induced changes were consistent between sessions but varied between tonometers. The measurement of IOP through soft contact lenses resulted in consistent, statistically significant differences in IOP, which were not uniform across tonometers and which did not appear to be solely related to the central thickness of the soft contact lenses. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Vermeltfoort, Pit B J; Rustema-Abbing, Minie; de Vries, Joop; Bruinsma, Gerda M; Busscher, Henk J; van der Linden, Matthijs L; Hooymans, Johanna M M; van der Mei, Henny C
2006-06-01
The aim of this study was to determine the effect of continuous wear on physicochemical surface properties of silicone hydrogel (S-H) lenses and their susceptibility to bacterial adhesion. In this study, volunteers wore 2 pairs of either "lotrafilcon A" or "balafilcon A" S-H contact lenses. The first pair was worn continuously for a week and the second pair for 4 weeks. One lens of each pair was used for surface characterization and the other one for bacterial adhesion experiments. Lens surfaces were characterized by examination of their wettability, roughness, elemental composition, and proteins attached to their surfaces. Adhesion of Staphylococcus aureus 835 and Pseudomonas aeruginosa #3 to a lens was studied using a parallel plate flow chamber. Before use, the lotrafilcon A lens was rougher than the balafilcon A lens and had a lower water contact angle and a higher affinity for S. aureus 835. After wear, both lens types had similar water contact angles, whereas the differences in elemental surface composition decreased as well. S. aureus 835 adhered in higher numbers to worn balafilcon A lenses, whereas the opposite was seen for P. aeruginosa #3. The initial deposition rates of both bacterial strains to lotrafilcon A lenses decreased by wearing and were found to correlate significant (P < 0.001) with the surface roughness of worn lenses. In this study, the differences in surface properties between 2 types of S-H lenses were found to change after 1 week of continuous wear. Generally, bacteria adhered in lower numbers and less tenaciously to worn lenses, except S. aureus 835, adhering in higher numbers to worn balafilcon A lenses.
Analysis of sub-bandage pressure of compression bandages during exercise.
Kumar, B; Das, A; Alagirusamy, R
2012-11-01
The sub-bandage pressure produced by any compression bandaging system is likely to vary during the physical activities taken by the patient. It is of significant importance to understand the variation of sub-bandage pressure during the exercise of calf muscle pump. The present paper aims to analyse the dominating factors and their interactions on the sub-bandage pressure during exercise. In this work the circumferential change of the leg because of the exercise of the calf muscle pump (expansion or contraction) is simulated using expansion or contraction actions of an air bladder placed on a mannequin. The study has been carried out using an indigenously developed prototype by pumping or squeezing of air in air bladder using cylinder-piston arrangement. A series of commercially available bandages were studied and the impact of the major factors, namely bandage extensibility (E), bandage tension (T) and the amount of bladder expansion or contraction (A) on the sub-bandage pressure during one cycle of expansion or contraction of air bladder have been analysed. Different levels of the factors have been chosen and a complete factorial design was prepared to obtain the sub-bandage pressure at all combination of the levels of the factors. The results showed that the sub-bandage pressure variations were higher for short-stretch bandage under dynamic mode (p value < 0.05). The variation in sub-bandage pressure were increased by increasing the amount of expansion or contraction of the air bladder and also increased when the bandage was wrapped at higher tension level (p-value < 0.05). N-way ANOVA results showed that some of the interactions effects of these above factors (EA and AT) also significantly affecting the sub-bandage pressure variations (p-value < 0.05). The prototype provides a simpler method to assess the bandage behaviour under different conditions without doing in vivo sub-bandage pressure measurement, and hence could be used to evaluate and compare the effectiveness of different compression bandage under different conditions, prior to their application on the wounded leg. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
... stopping to breast-feed if you use dexamethasone eye drops.tell your doctor if you wear soft contact lenses. If the brand of dexamethasone you are using contains benzalkonium chloride, wait at least 15 minutes after using the medicine to put in soft contact lenses.
The Danger of Using Tap Water with Contact Lenses
Acanthamoeba is a microbe that is very common in tap water. It has two forms: the trophozoite and the cyst. These trophozoites and cysts can stick to the surface of your contact lenses and then infect your eye.
Hotta, Fumika; Imai, Shoji; Miyamoto, Tatsuro; Mitamura-Aizawa, Sayaka; Mitamura, Yoshinori
2015-01-01
Objective: To investigate the surfaces and principal elements of the colorants of cosmetically tinted contact lenses (Cos-CLs). Methods: We analyzed the surfaces and principal elements of the colorants of five commercially available Cos-CLs using scanning electron microscopy with energy-dispersive x-ray analysis. Results: In two Cos-CLs, the anterior and posterior surfaces were smooth, and colorants were found inside the lens. One lens showed colorants located to a depth of 8 to 14 μm from the anterior side of the lens. In the other lens, colorants were found in the most superficial layer on the posterior surface, although a coated layer was observed. The colorants in the other three lenses were deposited on either lens surface. Although a print pattern was uniform in embedded type lenses, uneven patterns were apparent in dot-matrix design lenses. Colorants used in all lenses contained chlorine, iron, and titanium. In the magnified scanning electron microscopy images of a certain lens, chlorine is exuded and spread. Conclusions: Cosmetically tinted contact lenses have a wide variety of lens surfaces and colorants. Colorants may be deposited on the lens surface and consist of an element that has tissue toxicity. PMID:25799458
The effect of prescription eyewear on ocular exposure to ultraviolet radiation.
Rosenthal, F S; Bakalian, A E; Taylor, H R
1986-01-01
Several studies have suggested that ultraviolet radiation in sunlight may cause cataracts and other eye disease. We evaluated the effect of prescription eyewear in attenuating ocular exposure to ultraviolet radiation (UVR) in the sunlight portions of the ultraviolet spectrum (295-350 nm). Using natural sunlight as the source, the attenuation was measured with two ultraviolet detectors, one sensitive to only UVB (295-315 nm) and one sensitive to both UVA and UVB (295-350 nm). A random sample of spectacles, spectacle lenses, and contact lenses was examined. The average transmission, as measured with either detector, was highest for soft contact lenses, followed by glass spectacle lenses, untinted hard contact lenses, and plastic spectacle lenses. Measurements performed with mannikins wearing spectacles showed that an average of 6.6 per cent of incident radiation reached the eye even when the lenses were covered with black opaque tape. The amount of exposure was increased substantially when the spectacles were moved 0.6 cm away from the forehead. The results show that the protection against ultraviolet exposure provided by prescription eyewear is highly variable and depends largely on its composition, size, and wearing position. PMID:3752323
Effect of bandage thickness on interface pressure applied by compression bandages.
Al Khaburi, Jawad; Dehghani-Sanij, Abbas A; Nelson, E Andrea; Hutchinson, Jerry
2012-04-01
Medical compression bandages are widely used in the treatment of chronic venous disorder. In order to design effective compression bandages, researchers have attempted to describe the interface pressure applied by these bandages using mathematical models. This paper reports on the work carried out to derive the mathematical model used to describe the interface pressure applied by single-layer bandage using two different approaches. The first assumes that the bandage thickness is negligible, whereas the second model includes the bandage thickness. The estimated pressures using the two formulae are then compared, simulated over a 3D representation of a real leg and validated experimentally. Both theoretical and experimental results have shown that taking bandage thickness into consideration while estimating the pressures applied by a medical compression bandage will result in more accurate estimation. However, the additional accuracy is clinically insignificant. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
Contact lens rehabilitation following repaired corneal perforations
Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B
2006-01-01
Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877
In vitro and in vivo evaluation of novel ciprofloxacin-releasing silicone hydrogel contact lenses.
Hui, Alex; Willcox, Mark; Jones, Lyndon
2014-07-15
The purpose of this study was to evaluate ciprofloxacin-releasing silicone hydrogel contact lens materials in vitro and in vivo for the treatment of microbial keratitis. Model silicone hydrogel contact lens materials were manufactured using a molecular imprinting technique to modify ciprofloxacin release kinetics. Various contact lens properties, including light transmission and surface wettability, were determined, and the in vitro ciprofloxacin release kinetics elucidated using fluorescence spectrophotometry. The materials then were evaluated for their ability to inhibit Pseudomonas aeruginosa growth in vitro and in an in vivo rabbit model of microbial keratitis. Synthesized lenses had similar material properties to commercial contact lens materials. There was a decrease in light transmission in the shorter wavelengths due to incorporation of the antibiotic, but over 80% light transmission between 400 and 700 nm. Modified materials released for more than 8 hours, significantly longer than unmodified controls (P < 0.05). In vivo, there was no statistically significant difference between the number of colony-forming units (CFU) recovered from corneas treated with eye drops and those treated with one of two modified contact lenses (P > 0.05), which is significantly less than corneas treated with unmodified control lenses or those that received no treatment at all (P < 0.05). These novel contact lenses designed for the extended release of ciprofloxacin may be beneficial to supplement or augment future treatments of sight-threatening microbial keratitis. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
2014-05-13
use of systemic corticosteroids, abnormal ophthalmic examination, and topographic evidence of keratoconus or warpage from contact 4 lenses...Systemic medications were permitted unless they were known to affect the cornea. Soft contact lenses were removed at least thirty days and hard contact ... contact lens was placed at conclusion of the treatment. All eyes received standard postoperative management during the first week including topical
Optimization of ceragenins for prevention of bacterial colonization of hydrogel contact lenses.
Gu, Xiaobo; Jennings, Jacob D; Snarr, Jason; Chaudhary, Vinod; Pollard, Jacob E; Savage, Paul B
2013-09-17
We provided contact lens hydrogels with an antibacterial innate immune function using nonpeptide mimics of endogenous antimicrobial peptides. Antimicrobial peptide mimics, ceragenins, were prepared for either covalent attachment to hydrogels or for controlled elution from lenses. The lipophilicity of the ceragenins was varied incrementally to provide differing levels of association with hydrophobic domains in lenses. Ceragenin-containing lenses were challenged repeatedly with Staphylococcus aureus or Pseudomonas aeruginosa in nutrient media. Bacterial growth and biofilm formation on lenses were quantified. A ceragenin covalently fixed in lenses effectively inhibited S. aureus biofilm formation on lenses in 10% tryptic soy broth (approximately 3-log reduction), but did not reduce biofilm formation in 100% tryptic soy broth. Ceragenins designed to elute from lenses were incorporated at 1% relative to the dry weight of the lenses. The ceragenin with the optimal lipid content, CSA-138, prevented bacterial colonization of lenses for 15 days with P. aeruginosa and for 30 days with S. aureus (daily exchange of growth media and reinoculation with 10⁶ CFU). Measurement of CSA-138 elution showed that concentrations of the ceragenin never exceeded 5 μg/mL in a 24-hour period and that after 4 days of elution, concentrations dropped to <0.5 μg/mL, while maintaining antibacterial activity. Ceragenin CSA-138 appears well suited for providing an innate immune-like function to abiotic hydrogel contact lenses for extended periods of time. Elution of even low concentrations of CSA-138 (<0.5 μg) is sufficient to eliminate inocula of 10⁶ CFU of S. aureus and P. aeruginosa.
Broad spectrum antimicrobial activity of melimine covalently bound to contact lenses.
Dutta, Debarun; Cole, Nerida; Kumar, Naresh; Willcox, Mark D P
2013-01-07
To develop a stable antimicrobial contact lens, which is effective against the International Organization for Standardization (ISO) panel microorganisms, Acanthamoeba castellanii and drug resistant strains of Pseudomonas aeruginosa and Staphylococcus aureus. Melimine was covalently incorporated into etafilcon A lenses. The amount of peptide present on the lens surface was quantified using amino acid analysis. After coating, the heat stability (121°C), lens surface hydrophobicity (by captive bubble), and in vitro cytotoxicity to mouse L929 cells of the lenses were investigated. Antimicrobial activity against the micro-organisms was evaluated by viable plate count and fluorescence microscopy, measuring the proportion of cell death compared with control lenses with no melimine. The most effective concentration was determined to be 152 ± 44 μg lens(-1) melimine on the lens surface. After coating, lenses were relatively hydrophilic and were nontoxic to mammalian cells. The activity remained high after autoclaving (e.g., 3.1, 3.9, 1.2, and 1.0 log inhibition against P. aeruginosa, S. aureus, A. castellanii, and Fusarium solani, respectively). Fluorescence microscopy confirmed significantly reduced (P < 0.001) adhesion of viable bacteria to melimine contact lenses. Viable count confirmed that lenses were active against all the bacteria and fungi from the ISO panel, Acanthamoeba and gave at least 2 log inhibition against all the multidrug resistant S. aureus and P. aeruginosa strains. Melimine may offer excellent potential for development as a broad spectrum antimicrobial coating for contact lenses, showing activity against all the bacterial and fungal ISO panel microorganisms, Acanthamoeba, and antibiotic resistant strains of P. aeruginosa and S. aureus.
On-eye optical quality of daily disposable contact lenses for different wearing times.
Montés-Micó, Robert; Belda-Salmerón, Lurdes; Ferrer-Blasco, Teresa; Albarrán-Diego, César; García-Lázaro, Santiago
2013-09-01
To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analysed by fitting Zernike polynomials up to the 5th-order for 3 and 5-mm pupils. The optical quality under each condition and at each point in time was described by means of the Root-Mean-Square (RMS) value of wavefront aberration, Modulation Transfer Function (MTF), Point Spread Function and cut-off spatial frequency. A RMS increase was observed after contact lens fitting as well as over time, both for a 3-mm and a 5-mm pupil. Each type of lens induced a different amount of wavefront aberrations, which vary over time also in a different manner. Dailies Total1 showed the lowest RMS values both at baseline and at the end of the day. In addition, Dailies Total1 provided the best MTF out of all the contact lenses that were assessed. These observations were reflected in higher cut-off spatial frequencies and visual resolution both at baseline and after 12 h of wearing time. Aberrometry makes it possible to analyse accurately and in vivo the optical quality of contact lenses and to assess how lenses having different characteristics - such as material or water content - behave for different wearing times. These variations across contact lenses may result in differences in visual performance. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.
Evaluation of wound healing potential of β-chitin hydrogel/nano zinc oxide composite bandage.
P T, Sudheesh Kumar; Lakshmanan, Vinoth-Kumar; Raj, Mincy; Biswas, Raja; Hiroshi, Tamura; Nair, Shantikumar V; Jayakumar, Rangasamy
2013-02-01
β-chitin hydrogel/nZnO composite bandage was fabricated and evaluated in detail as an alternative to existing bandages. β-chitin hydrogel was synthesized by dissolving β-chitin powder in Methanol/CaCl(2) solvent, followed by the addition of distilled water. ZnO nanoparticles were added to the β-chitin hydrogel and stirred for homogenized distribution. The resultant slurry was frozen at 0°C for 12 h. The frozen samples were lyophilized for 24 h to obtain porous composite bandages. The bandages showed controlled swelling and degradation. The composite bandages showed blood clotting ability as well as platelet activation, which was higher when compared to the control. The antibacterial activity of the bandages were proven against Staphylococcus aureus (S. aureus) and Escherichia coli (E.coli). Cytocompatibility of the composite bandages were assessed using human dermal fibroblast cells (HDF) and these cells on the composite bandages were viable similar to the Kaltostat control bandages and bare β-chitin hydrogel based bandages. The viability was reduced to 50-60% in bandages with higher concentration of zinc oxide nanoparticles (nZnO) and showed 80-90% viability with lower concentration of nZnO. In vivo evaluation in Sprague Dawley rats (S.D. rats) showed faster healing and higher collagen deposition ability of composite bandages when compared to the control. The prepared bandages can be used on various types of infected wounds with large volume of exudates.
Surgery-Related Contact Dermatitis: A Review of Potential Irritants and Allergens.
Cook, Kevin A; Kelso, John M
Surgical procedures utilize an increasing number of medical products including antiseptics, anesthetics, gloves, suture materials, tissue adhesives, topical antibiotics, and bandages. Many of these products have irritant potential. Allergic contact dermatitis has also been reported. This review covers preoperative, operative, and postoperative exposures that may result in contact dermatitis. Testing with standard patch panels such as T.R.U.E. Test and the North American Contact Dermatitis Group 65 allergen series does not evaluate for all relevant contactants. A thorough understanding of potential exposures is vital to effectively evaluate a patient with surgery-related contact dermatitis. A systematic approach is needed to ensure that standard patch panels and supplementary patches adequately address each encountered contactant. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Liu, Jun; He, Xiaoyin; Pan, Xueliang; Roberts, Cynthia J
2007-01-01
Non-invasive measurement of biomechanical properties of corneas may provide important information for ocular disease management and therapeutic procedures. An ultrasonic non-destructive evaluation method with a wave propagation model was developed to determine corneal biomechanical properties in vivo. In this study, we tested the feasibility of the approach in differentiating the mechanical properties of soft contact lenses as corneal phantoms. Three material types of soft contact lenses (six samples in each group) were measured using a broadband ultrasound transducer. The ultrasonic reflections from the contact lenses were recorded by a 500MHz/8-bit digitizer, and displayed and processed by a PC. A reference signal was recorded to compute the normalized power spectra using Fast Fourier Transformation. An inverse algorithm based on least-squares minimization was used to reconstruct three parameters of the contact lenses: density, thickness, and elastic constants lambda+2micro. The thickness of each sample was verified using an electronic thickness gauge, and the averaged density for each type of lenses was verified using Archimedes' principle and manufacturer's report. Our results demonstrated that the ultrasonic system was able to differentiate the elastic properties of the three types of the soft contact lenses with statistical significance (P-value<0.001). The reconstructed thicknesses and densities agreed well with the independent measurements. Our studies on corneal phantoms indicated that the ultrasonic system was sensitive and accurate in measuring the material properties of cornea-like structures. It is important to optimize the system for in vivo measurements.
Sustained Ocular Delivery of Ciprofloxacin Using Nanospheres and Conventional Contact Lens Materials
Garhwal, Rahul; Shady, Sally F.; Ellis, Edward J.; Ellis, Jeanne Y.; Leahy, Charles D.; McCarthy, Stephen P.; Crawford, Kathryn S.
2012-01-01
Purpose. To formulate conventional contact lenses that incorporate nanosphere-encapsulated antibiotic and demonstrate that the lenses provide for sustained antibacterial activity. Methods. A copolymer composed of pullulan and polycaprolactone (PCL) was used to synthesize core-shell nanospheres that encapsulated ciprofloxacin. Bactericidal activity of the nanosphere-encapsulated ciprofloxacin (nanosphere/cipro) was tested by using liquid cultures of either Staphylococcus aureus or Pseudomonas aeruginosa. Nanosphere/cipro was then incorporated into HEMA-based contact lenses that were tested for growth inhibition of S. aureus or P. aeruginosa in liquid cultures inoculated daily with fresh bacteria. Lens designs included thin or thick lenses incorporating nanosphere/cipro and ciprofloxacin-HCl-soaked Acuvue lenses (Acuvue; Johnson & Johnson Vision Care, Inc., Jacksonville, FL). Results. Less than 2 μg/mL of nanosphere/cipro effectively inhibited the proliferation of cultures inoculated with 107 or 108 bacteria/mL of S. aureus and P. aeruginosa, respectively. HEMA-based contact lenses polymerized with nanosphere/cipro were transparent, effectively inhibited the proliferation of greater than 107/mL of bacteria added daily over 3 days of culture, and killed up to 5 × 109 total microbes in a single inoculation. A thicker lens design provided additional inhibition of bacterial growth for up to 96 hours. Conclusions. Core-shell nanospheres loaded with an antibiotic can be incorporated into a conventional, transparent contact lens and provide for sustained and effective bactericidal activity and thereby provide a new drug delivery platform for widespread use in treating ocular disorders. PMID:22266514
... by soft contact lenses. If you wear contact lenses, remove them before instilling bimatoprost and put them back in 15 minutes later.if you have an eye injury, infection, or surgery while using bimatoprost, ask your doctor if you should continue using the same eye drop container.
Surface chemical structure for soft contact lenses as a function of polymer processing.
Grobe, G L; Valint, P L; Ammon, D M
1996-09-01
The surface chemistry and topography of cast-molded Etafilcon-A and doubled-sided lathed Etafilcon-A soft contact lenses were determined to be significantly different. The variations in surface chemical and morphologic structure between the two lenses were the result of contact lens manufacturing methods. The surface of the cast-molded Etafilcon-A had a consistently less rough surface compared to the doubled sided lathed Etafilcon-A as determined by atomic force microscopy. The surface of the doubled sided lathed Etafilcon-A contained primarily silicone and wax contamination in addition to minute amounts of HEMA. The cast-molded Etafilcon-A had an elemental and chemical content which was consistent with the polymer stoichiometry. Contact angle wettability profiles revealed inherent wettability differences between the two lenses types. The cast-molded Etafilcon-A had an inherently greater water wettability, polarity, and critical surface tension. This means that these two lenses cannot be compared as similar or identical lens materials in terms of surface composition. The manufacturing method used to produce a soft contact lens directly determines the surface elemental and chemical structure as well as the morphology of the finished lens material. These results suggest possible differences in the clinical comfort, spoilage, and lubricity felt during patient wear.
Hydrogen peroxide mechanosynthesis in siloxane-hydrogel contact lenses.
Tavazzi, Silvia; Ferraro, Lorenzo; Cozza, Federica; Pastori, Valentina; Lecchi, Marzia; Farris, Stefano; Borghesi, Alessandro
2014-11-26
Drug-loaded contact lenses are emerging as the preferred treatment method for several ocular diseases, and efforts are being directed to promote extended and controlled delivery. One strategy is based on delivery induced by environmental triggers. One of these triggers can be hydrogen peroxide, since many platforms based on drug-loaded nanoparticles were demonstrated to be hydrogen-peroxide responsive. This is particularly interesting when hydrogen peroxide is the result of a specific pathophysiological condition. Otherwise, an alternative route to induce drug delivery is here proposed, namely the mechano-synthesis. The present work represents the proof-of-concept of the mechanosynthesis of hydrogen peroxide in siloxane-hydrogel contact lenses as a consequence of the cleavage of siloxane bonds at the interface between the polymer and water in aqueous phase. Their spongy morphology makes contact lenses promising systems for mechanical-to-chemical energy conversion, since the amount of hydrogen peroxide is expected to scale with the interfacial area between the polymer and water. The eyelid pressure during wear is sufficient to induce the hydrogen peroxide synthesis with concentrations which are biocompatible and suitable to trigger the drug release through hydrogen-peroxide-responsive platforms. For possible delivery on demand, the integration of piezoelectric polymers in the siloxane-hydrogel contact lenses could be designed, whose mechanical deformation could be induced by an applied wireless-controlled voltage.
An early assessment of silicone hydrogel safety: pearls and pitfalls, and current status.
Keay, Lisa; Edwards, Katie; Stapleton, Fiona
2007-11-01
The contact lens industry has evolved and now provides many choices, including continuous wear, overnight orthokeratology, frequent-replacement lenses, daily-disposable lenses, and many alternatives in systems of care and maintenance. Epidemiologic studies to date have shown that how a lens is worn, particularly if worn overnight, can increase the risk of microbial keratitis. However, the risk of silicone hydrogel contact lenses worn on a continuous-wear basis has been evaluated only recently. This article summarizes the recent research data on extended-wear silicone hydrogel lenses and discusses the challenges of early evaluations of silicone hydrogel lens safety. Finally, the relevance of this information is discussed to practitioners and contact lens wearers making choices about the risks and benefits of different products and how they are used.
In Vitro Spoilation of Silicone-Hydrogel Soft Contact Lenses in a Model-Blink Cell.
Peng, Cheng-Chun; Fajardo, Neil P; Razunguzwa, Trust; Radke, Clayton J
2015-07-01
We developed an in vitro model-blink cell that reproduces the mechanism of in vivo fouling of soft contact lenses. In the model-blink cell, model tear lipid directly contacts the lens surface after forced aqueous rupture, mirroring the pre-lens tear-film breakup during interblink. Soft contact lenses are attached to a Teflon holder and immersed in artificial tear solution with protein, salts, and mucins. Artificial tear-lipid solution is spread over the air/tear interface as a duplex lipid layer. The aqueous tear film is periodically ruptured and reformed by withdrawing and reinjecting tear solution into the cell, mimicking the blink-rupture process. Fouled deposits appear on the lenses after cycling, and their compositions and spatial distributions are subsequently analyzed by optical microscopy, laser ablation electrospray ionization mass spectrometry, and two-photon fluorescence confocal scanning laser microscopy. Discrete deposit (white) spots with an average size of 20 to 300 μm are observed on the studied lenses, confirming what is seen in vivo and validating the in vitro model-blink cell. Targeted lipids (cholesterol) and proteins (albumin from bovine serum) are identified in the discrete surface deposits. Both lipid and protein occur simultaneously in the surface deposits and overlap with the white spots observed by optical microscopy. Additionally, lipid and protein penetrate into the bulk of tested silicone-hydrogel lenses, likely attributed to the bicontinuous microstructure of oleophilic silicone and hydrophilic polymer phases of the lens. In vitro spoilation of soft contact lenses is successfully achieved by the model-blink cell confirming the tear rupture/deposition mechanism of lens fouling. The model-blink cell provides a reliable laboratory tool for screening new antifouling lens materials, surface coatings, and care solutions.
Sustained compression and healing of chronic venous ulcers.
Blair, S. D.; Wright, D. D.; Backhouse, C. M.; Riddle, E.; McCollum, C. N.
1988-01-01
STUDY OBJECTIVE--Comparison of four layer bandage system with traditional adhesive plaster bandaging in terms of (a) compression achieved and (b) healing of venous ulcers. DESIGN--Part of larger randomised trial of five different dressings. SETTING--Outpatient venous ulcer clinic in university hospital. PATIENTS--(a) Pressure exerted by both bandage systems was measured in the same 20 patients. (b) Healing with the four layer bandage was assessed in 148 legs in 126 consecutive patients (mean age 71 (SE 2); range 30-96) with chronic venous ulcers that had resisted treatment with traditional bandaging for a mean of 27.2 (SE 8) months. INTERVENTIONS--(a) Four layer bandage system or traditional adhesive plaster bandaging for pressure studies; (b) four layer bandaging applied weekly for studies of healing. END POINTS--(a) Comparison of pressures achieved at the ankle for up to one week; (b) complete healing within 12 weeks. MEASUREMENTS AND MAIN RESULTS--(a) Four layer bandage produced higher initial pressures at the ankle of 42.5 (SE 1) mm Hg compared with 29.8 (1.8) for the adhesive plaster (p less than 0.001; 95% confidence interval 18.5 to 6.9). Pressure was maintained for one week with the four layer bandage but fell to 10.4 (3.5) mm Hg at 24 hours with adhesive plaster bandaging. (b) After weekly bandaging with the four layer bandage 110 of 48 venous ulcers had healed completely within 12 (mean 6.3 (0.4)) weeks. CONCLUSION--Sustained compression of over 40 mm Hg achieved with a multilayer bandage results in rapid healing of chronic venous ulcers that have failed to heal in many months of compression at lower pressures with more conventional bandages. PMID:3144330
Drug delivery through soft contact lenses.
Jain, M. R.
1988-01-01
Clinical studies were conducted on 466 patients waiting for senile cataract surgery and receiving chloromycetin, gentamicin, or carbenicillin subconjunctivally and through New Sauflon 70 and New Sauflon 85 lenses. The aqueous drug levels were biologically estimated at various time intervals. Soft contact lenses provided significantly higher drug penetration than subconjunctival therapy. Both modes of treatment provided therapeutically effective levels against most of the common ocular pathogens for varying intervals of 2 to 12 hours. PMID:3349016
An Analysis of Eye Movements with Helmet Mounted Displays
2014-03-27
YES/NO Have you had corrective eye surgery ( PRK / LASIK )? YES/NO Have you been diagnosed or treated for any eye injuries or disease(s)? YES...without the use of any type of corrective lenses (glasses or contacts). Those with corrective vision through LASIK or PRK are qualified. Additionally...breast implants? YES/NO Do you wear corrective lenses (glasses/contact lenses)? YES/NO Have you had corrective eye surgery ( PRK / LASIK
... by soft contact lenses. If you wear contact lenses, remove them before instilling travoprost and put them back in 15 minutes later.if you have an eye injury, infection, or surgery while using travoprost eye drops, ask your doctor if you should continue using the same eye drops container.
Multifocal rigid gas permeable contact lenses with reduced halo
NASA Astrophysics Data System (ADS)
ben Yaish, Shai; Zlotnik, Alex; Limon, Ofer; Lahav Yacouel, Karen; Doron, Ravid; Zalevsky, Zeev
2014-05-01
In this communication we present the first dispensing medical trial in which we successfully report on testing of novel extended depth of focus rigid gas permeable (RGP) contact lenses having reduced halo and distinct focal peaks for near and far distance vision.
Code of Federal Regulations, 2013 CFR
2013-07-01
... lenses than by eyeglass lenses, as corrected by contact lenses. (3) In any case where the examiner... these cases, evaluate based on corrected distance vision adjusted to one step poorer than measured. (4...
Code of Federal Regulations, 2012 CFR
2012-07-01
... lenses than by eyeglass lenses, as corrected by contact lenses. (3) In any case where the examiner... these cases, evaluate based on corrected distance vision adjusted to one step poorer than measured. (4...
Code of Federal Regulations, 2014 CFR
2014-07-01
... lenses than by eyeglass lenses, as corrected by contact lenses. (3) In any case where the examiner... these cases, evaluate based on corrected distance vision adjusted to one step poorer than measured. (4...
The effect of the timing of the cessation of contact lens use on the results of biometry.
Goudie, Colin; Tatham, Andrew; Davies, Rhys; Sifton, Alison; Wright, Mark
2018-06-01
Current guidelines vary regarding when to remove contact lenses prior to performing biometry, and there is no clear evidence behind these guidelines. This study aimed to determine the effect of soft contact lens wear on biometric measurements by examining the change in predicted lens power for emmetropia at several time points following removal of soft contact lenses. A prospective, controlled study of healthy soft contact lens wearers. Biometry was performed immediately after removing contact lenses and then after 2, 4 and 7 days of no contact lens use. Healthy non-contact lens wearers were used as controls. All measurements were taken with the Zeiss IOLMaster. In all, 14 subjects and 13 controls were recruited. There was no significant difference in age or gender between groups. Eight of the fourteen subjects wore daily disposable CLs, two wore 2-weekly and four wore monthly soft CLs. Measurements from controls and contact lens-wearing subjects showed similar degrees of variation over time. The within-subject SD in predicted intraocular lens (IOL) power for emmetropia for contact lens wearers was 0.20 D (95% CI 0.16-0.25 D) compared to 0.18 D (95% CI 0.12-0.26 D) for controls. There is a significant variation in UK practice regarding advice on the timing of cessation of contact lens wear prior to having biometry performed. Our study suggests that it is likely that soft contact lens wearers are currently being advised to remove their contact lenses for an unnecessarily long period of time prior to having biometry performed.
Conjunctival epithelial flap in continuous contact lens wear.
Graham, Andrew D; Truong, Tan N; Lin, Meng C
2009-04-01
Composed of sheets of cells detached from the underlying conjunctiva, conjunctival epithelial flap (CEF) is a recently reported phenomenon associated with contact lens wear with potential consequences for ocular health. Although CEF is generally asymptomatic, it is not known to what extent it might increase the longer-term risk of discomfort, inflammatory response, or infection. In this study, we use survival analysis methods to obtain unbiased estimates of the probability of developing CEF, the mean survival time free of CEF, and the effects of age, gender, ethnicity, and contact lens type. Two hundred four subjects were recruited for a continuous wear (CW) study of silicone hydrogel (SiH) and gas permeable (GP) contact lenses. Subjects were examined by optometrists throughout contact lens adaptation and CW periods. Statistical methods included the Kaplan-Meier nonparametric estimator of the survival function and the Cox proportional hazards model for estimating the relative effects of covariates. Of the 204 subjects, 72 (35%) developed CEF. In 64% of cases, CEFs were observed bilaterally. The majority of cases (90.3%) presented with CEF in the superior conjunctiva. Mean survival time free of CEF was longer for GP lenses (94.3 days) than for SiH lenses (76.5 days), and the probability of developing CEF was significantly greater for SiH lenses (p = 0.002). Although there was some evidence that women and non-Asians remain free of CEF longer, the effects of age, gender, and ethnicity were not statistically significant. There was a significantly increased risk of CEF in subjects wearing SiH lenses, compared with GP lenses. Subjects wearing SiH lenses remained free of CEF for a shorter time on average. Further study is needed to determine whether the increased incidence of CEF in CW with SiH lenses poses an increased risk of adverse ocular response or infection.
Suchecki, Jeanine K; Donshik, Peter; Ehlers, William H
2003-09-01
Complications associated with contact lenses range from mild to severe and occur with all lens modalities. Contact lens wear can cause a change in corneal physiology, which can lead to epithelial, stromal, and endothelial compromise. Other complications include lens deposition, allergic conjunctivitis, giant papillary conjunctivitis, peripheral infiltrates, microbial keratitis, and neovascularization. Pre-existing conditions can contribute to these complications, or they can occur in association with contact lens wear and care regimens. Patient-related factors, such as alteration of the recommended wearing or replacement schedules and noncompliance with recommended contact lens care regimens for economic reasons, convenience, or in error, contribute to contact lens-related complications and have led to difficulty in accurate determination of complication rates among the various lens wear modalities. Complications may require discontinuation of contact lenses, topical therapy, and changes in contact lens wearing schedules, materials, and care solutions. On initial lens fitting and follow-up evaluations, practitioners should review contact lens replacement and cleaning regimens with patients and discuss complications. To avoid serious complications, patients should be reminded to remove their contact lenses as soon as ocular irritation occurs, and to call their eye care practitioner immediately if symptoms persist.
Sankaridurg, Padmaja R.; Sharma, Savitri; Willcox, Mark; Naduvilath, Thomas J.; Sweeney, Deborah F.; Holden, Brien A.; Rao, Gullapalli N.
2000-01-01
Microorganisms, especially gram-negative bacteria, are considered to play a role in the etiology of certain corneal infiltrative events (CIEs) observed during soft contact lens wear. This study explored the possibility of microbial colonization of soft contact lenses as a risk factor leading to CIEs. In a clinical trial conducted from March 1993 to January 1996, 330 subjects wore disposable soft contact lenses on a 6-night extended-wear and disposal schedule. During this period, 4,321 lenses (118 during CIEs; 4,203 during asymptomatic lens wear) were recovered aseptically and analyzed for microbial colonization. A greater percentage of lenses were free from microbial colonization during asymptomatic wear than during CIEs (42 versus 23%; P < 0.0001). The incidence of gram-positive bacteria, gram-negative bacteria and fungi was greater during CIEs than during asymptomatic lens wear (P < 0.05). During asymptomatic lens wear, gram-positive bacteria were isolated most frequently and were usually normal external ocular microbiota. Of the gram-positive bacteria, the incidence of Streptococcus pneumoniae was greater during CIE than during asymptomatic wear (7.6 versus 0.6%; P < 0.0001). While gram-negative bacteria were seen in few cases during asymptomatic wear, their incidence during CIE in comparison to asymptomatic wear was substantial and significant (23.7 versus 3.8%; P < 0.0001). Also, the level of colonization was high. Of CIEs, events of microbial keratitis, contact lens acute red eye, and asymptomatic infiltrative keratitis were associated with lens colonization with gram-negative bacteria or S. pneumoniae. Colonization of soft contact lenses with pathogenic bacteria, especially gram-negative bacteria and S. pneumoniae, appears to be a significant risk factor leading to CIE. PMID:11101574
Walsh, James E; Bergmanson, Jan P G; Saldana, Gerardo; Gaume, Amber
2003-01-01
Peak solar UV radiation (UVR) intensities are typically experienced in summer months. People living in the southern states of the United States, where the UVR frequently exceeds the recommended minimum erythema dose (MED), are at particular risk, especially outdoor workers. The present study analyzed summertime MED readings in Houston, TX, to assess the frequency of intensities regarded as unhealthy. The study also sought to assess whether UV-blocking hydrogel contact lenses provide ocular protection from these high doses. Readings, taken at midday using a UVR biometer, were analyzed to assess the potential UVR risk. The spectral response of the meter, modified by the spectral transmission curves of the contact lenses, allowed us to mathematically assess the ocular protection provided. In addition, ambient UVR measurements were taken at midday, using a portable UVR radiometer. The detector was adapted so that a standard diameter hydrogel contact lens could be placed over it to quantify the UV-blocking capabilities of the lens. The MED readings showed that the recommended safety standards were exceeded approximately at local midday 90% of the time. Model calculations and empirical data demonstrated that contact lenses attenuated the MED readings by up to 90%, bringing them well within the recommended Environmental Protection Agency safety standards. The efficacy of the model used in this study was verified through direct comparison of the modeled and measured data. UV-blocking hydrogel soft contact lenses reduce the MED to the human eye and therefore limit the lifetime ocular dose. These lenses are highly recommended to prevent the development of UVR-related ocular pathologic conditions.
Marx, Sebastian; Sickenberger, Wolfgang
2017-12-01
This study was designed to develop a novel technique called non-invasive keratograph dry-up time (NIK-DUT), which used an adapted corneal topographer, to analyse in-vitro contact lens surface dewetting and the effects of combinations of lenses and lens care solutions on dewetting. Variables were assessed to optimise sensitivity and reproducibility. To validate the method, in-vitro dewetting of silicone hydrogel contact lenses (balafilcon A, comfilcon A, lotrafilcon A, lotrafilcon B and senofilcon A) was tested. All lens types were soaked in OPTI-FREE ® PureMoist ® Multipurpose Disinfecting Solution (OFPM) and Sensitive Eyes ® Saline Solution. The mean NIK-DUT, defined as drying of 25% of the placido ring measurement segments (NIK-DUT_S25), was calculated for each lens/lens solution combination and a visual map constructed representing the time and location of the dry-up event. Optimal conditions for NIK-DUT measurement included mounting onto a glass stage with a surface geometry of r=8.5mm, e=0, and measuring with high intensity red or white illumination. This method detected significant differences in contact lens dewetting with different lens soaking solutions. NIK-DUT_S25 for all lenses was longer when pre-soaked in OFPM versus saline. Visual analysis showed that dewetting of contact lenses was not uniform across surfaces and differed between test solutions. NIK-DUT is suitable for detecting differences in dewetting among various contact lenses and lens-care combinations. NIK-DUT can quantify the dewetting of large areas of lens surfaces with little subjective influence. Lens care solutions containing surface-active wetting agents were found to delay surface dewetting of silicone hydrogel lenses. Copyright © 2017. Published by Elsevier Ltd.
Henriques, Mariana; Sousa, Cláudia; Lira, Madalena; Elisabete, M; Oliveira, Real; Oliveira, Rosário; Azeredo, Joana
2005-06-01
The purpose of this study is to compare the adhesion capabilities of the most important etiologic agents of microbial ocular infection to the recently available silicone-hydrogel lenses with those to a conventional hydrogel lens. In vitro static adhesion assays of Pseudomonas aeruginosa 10,145, Staphylococcus epidermidis 9142 (biofilm-positive), and 12,228 (biofilm-negative) to two extended-wear silicone-hydrogel lenses (balafilcon A and lotrafilcon A), a daily wear silicone-hydrogel lens (galyfilcon A) and a conventional hydrogel (etafilcon A) were performed. To interpret the adhesion results, lens surface relative hydrophobicity was assessed by water contact angle measurements. P. aeruginosa and S. epidermidis 9142 exhibited greater adhesion capabilities to the extended wear silicone-hydrogel lenses than to the daily wear silicone- and conventional hydrogel lenses (p < 0.05). No statistical differences were found between the adhesion extent of these strains to galyfilcon A and etafilcon A. The biofilm negative strain of S. epidermidis adhered in larger extents to the silicone-hydrogel lenses than to the conventional hydrogel (p < 0.05), but in much lower amounts than the biofilm-positive strain. The water contact angle measurements revealed that the extended wear silicone-hydrogel lenses are hydrophobic, whereas the daily wear silicone- and conventional hydrogel lenses are hydrophilic. As a result of their hydrophobicity, the extended wear silicone-hydrogel lenses (lotrafilcon A and balafilcon A) may carry higher risk of microbial contamination than both the hydrophilic daily wear silicone-hydrogel lens, galyfilcon A and the conventional hydrogel lens, etafilcon A.
Trends in the use of silicone hydrogel contact lenses for daily wear.
Efron, Nathan; Morgan, Philip B
2008-10-01
Although the first silicone hydrogel contact lenses introduced onto the world contact lens market in 1999 held approval for both daily wear and extended wear use, the latter modality was promoted much more heavily by the manufacturers. The first silicone hydrogel lenses specifically promoted for daily wear were introduced in 2003. Data that we have gathered from annual contact lens fitting surveys demonstrate an immediate increase in market share whereby this lens type now represents more than one-third of soft lens fits in the United Kingdom. The success of this lens category is attributed to the health and safety benefits of silicone hydrogel materials and the positive impact of lens manufacturers by way of the effective marketing and distribution of these products.
Controlled release of betamethasone from vitamin E-loaded silicone-based soft contact lenses.
Rad, Maryam Shayani; Sajadi Tabassi, Sayyed Abolghasem; Moghadam, Maryam Hassanpour; Mohajeri, Seyed Ahmad
2016-11-01
Betamethasone (BMZ) is an effective drug which is commonly used as an eye drop for the management of ophthalmic inflammations. Due to low ocular bioavailability, it is necessary to prepare and optimize an ocular drug delivery system for BMZ. In this study we tried to use vitamin E diffusion barrier for sustaining BMZ release. Three commercial contact lenses were soaked in vitamin E solutions and swelling percentage, diameter, transmittance, binding capacity and release amount and time were evaluated in comparison with non-vitamin E-loaded pure lenses. The results showed that vitamin E significantly decreased water content of contact lenses whereas, increased the lens diameter in both dry and wet states. It effectively blocked UV radiation which is harmful for the eye surface while had no significant effect on visible transmittance. BMZ loading capacity enhanced and release rate remarkably decreased after using vitamin E as a hydrophobic diffusion barrier. This study revealed that vitamin E can be applied as a hydrophobic diffusion barrier for controlling and sustaining BMZ release from silicone-based soft contact lenses into the lachrymal fluid. It can also protect eye tissues as an antioxidant by blocking the UV radiation.
14 CFR 125.207 - Emergency equipment requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Administrator: Contents Quantity Adhesive bandage compressors, 1 in 16 Antiseptic swabs 20 Ammonia inhalants 10 Bandage compressors, 4 in 8 Triangular bandage compressors, 40 in 5 Arm splint, noninflatable 1 Leg splint, noninflatable 1 Roller bandage, 4 in 4 Adhesive tape, 1-in standard roll 2 Bandage scissors 1 Protective latex...
14 CFR 125.207 - Emergency equipment requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Administrator: Contents Quantity Adhesive bandage compressors, 1 in 16 Antiseptic swabs 20 Ammonia inhalants 10 Bandage compressors, 4 in 8 Triangular bandage compressors, 40 in 5 Arm splint, noninflatable 1 Leg splint, noninflatable 1 Roller bandage, 4 in 4 Adhesive tape, 1-in standard roll 2 Bandage scissors 1 Protective latex...
14 CFR 125.207 - Emergency equipment requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Administrator: Contents Quantity Adhesive bandage compressors, 1 in 16 Antiseptic swabs 20 Ammonia inhalants 10 Bandage compressors, 4 in 8 Triangular bandage compressors, 40 in 5 Arm splint, noninflatable 1 Leg splint, noninflatable 1 Roller bandage, 4 in 4 Adhesive tape, 1-in standard roll 2 Bandage scissors 1 Protective latex...
14 CFR 125.207 - Emergency equipment requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Administrator: Contents Quantity Adhesive bandage compressors, 1 in 16 Antiseptic swabs 20 Ammonia inhalants 10 Bandage compressors, 4 in 8 Triangular bandage compressors, 40 in 5 Arm splint, noninflatable 1 Leg splint, noninflatable 1 Roller bandage, 4 in 4 Adhesive tape, 1-in standard roll 2 Bandage scissors 1 Protective latex...
[Laboratory study of the cytotoxicity of colored soft contact lenses].
Almesmary, A A
1999-01-01
In the clinical practice we have met with the fact that some patients did not tolerate soft coloured contact lenses even when they used them for a short time. To find whether the cause is the composition of these lenses, mainly the adding of stain, he used the laboratory test to determine cytotoxicity, the test of dynamic observation of cytotoxicity where the cells cultured in vitro are the experimental object. On the basis of the results of this test commonly used for the determination of the cytotoxicity of implantation materials, he thinks that the cause of intolerance of coloured lenses is not their toxicity but other phenomena. An individual hypersensitivity or insufficient care of lenses (the influence of disinfectants) can be among these causes.
[Giant papillary conjunctivitis].
Bischoff, G
2014-05-01
Giant papillary conjunctivitis is an inflammation of the conjunctiva, which is associated with immunological-allergic disorders, but is difficult to integrate as a defined type of illness. The deposits of contact lenses are responsible in predisposed wearers. They induce a special immune answer to their biochemical ingredients. In addition, roughness of the superficial corneal layers and the conjunctiva, even without any contact lenses after filtrating glaucoma surgery, leads to mechanically induced papillary formations. In former days these symptoms of building giant papillae were seen mostly in wearers of soft hydrogel contact lenses. Nowadays manufacturers have developed contact lens systems with a variety of material components, with an increase of protein and lipid deposits. In combination with the observed non-compliance of wearers regarding lens exchange and contact lens hygiene, GPC is an issue which should be taken into consideration again. Georg Thieme Verlag KG Stuttgart · New York.
... see if you should still use the same eye drop bottle.tell your doctor if you wear soft contact lenses. Wait at least 15 minutes after using the medicine to put in soft contact lenses.use caution when driving or operating machinery because vision may be blurred after inserting the drops.
The use of contact lenses in low vision rehabilitation: optical and therapeutic applications.
Vincent, Stephen J
2017-09-01
Ocular pathology that manifests at an early age has the potential to alter the vision-dependent emmetropisation mechanism, which co-ordinates ocular growth throughout childhood. The disruption of this feedback mechanism in children with congenital or early-onset visual impairment often results in the development of significant ametropia, including high levels of spherical refractive error, astigmatism and anisometropia. This review examines the use of contact lenses as a refractive correction, low vision aid and therapeutic intervention in the rehabilitation of patients with bilateral, irreversible visual loss due to congenital ocular disease. The advantages and disadvantages of the use of contact lenses for increased magnification (telescopes and microscopes) or field expansion (reverse telescopes) are discussed, along with the benefits and practical considerations for the correction of pathological high myopia. The historical and present use of therapeutic tinted contact lenses to reduce photosensitivity and nystagmus in achromatopsia, albinism and aniridia are also presented, including clinical considerations for the contact lens practitioner. In addition to the known optical benefits in comparison to spectacles for high levels of ametropia (an improved field of view for myopes and fewer inherent oblique aberrations), contact lenses may be of significant psycho-social benefit for patients with low vision, due to enhanced cosmesis and reduced conspicuity and potential related effects of improved self-esteem and peer acceptance. The contact lens correction of patients with congenital vision impairment can be challenging for both practitioner and patient but should be considered as a potential optical or therapeutic solution in modern low vision rehabilitation. © 2017 Optometry Australia.
Maïssa, Cécile; Guillon, Michel; Garofalo, Renee J
2012-01-01
The principal objective of the study was to measure the conjunctival staining produced in the circumlimbal region by silicone hydrogel contact lenses with different edge designs. The secondary objective was to investigate the association between circumlimbal staining and comfort. Four silicone hydrogel contact lenses: ACUVUE OASYS (knife edge design), AIR OPTIX, Biofinity (chisel edge rounded edge combination), and PureVision (rounded edge design), and 1 hydrogel contact lens, ACUVUE 2 (knife edge design), were tested. The study was conducted on a cohort population of 27 established soft contact lens wearers, who wore each contact lens type, in a random order, for a period of 10 (±2) days. Circumlimbal staining was measured in a double-masked fashion through image analysis of digital photographs of lissamine green taken under controlled experimental conditions. The results obtained showed that contact lens edge design was the primary factor controlling circumlimbal staining for silicone hydrogel lenses: a rounded edge away from the ocular surface produced the lowest staining (average, 0.19%) and a knife edge in close apposition to the ocular surface produced the highest staining (average, 1.34%). Contact lens material rigidity was also identified to affect circumlimbal staining and an inverse association between circumlimbal staining and contact lens comfort was demonstrated: the rounded edge design produced the lowest comfort (72 of 100) and the knife edge design produced the highest (87 out of 100). Soft contact lens wear induces circumlimbal staining, the level of staining being influenced by the contact lens edge design. However, high level of circumlimbal staining is not associated with decreased comfort.
Controlled Release of Antibiotics From Vitamin E-Loaded Silicone-Hydrogel Contact Lenses.
Paradiso, Patrizia; Serro, Ana Paula; Saramago, Benilde; Colaço, Rogério; Chauhan, Anuj
2016-03-01
Symptoms of bacterial and fungal keratitis are typically treated through the frequent application of antibiotic and antifungal eye drops. The high frequency of half hourly or hourly eye drop administration required to treat these indications is tedious and could reduce compliance. Here, we combine in vitro experiments with a mathematical model to develop therapeutic soft contact lenses to cure keratitis by extended release of suitable drugs. We specifically focus on increasing the release duration of levofloxacin and chlorhexidine from 1-DAY ACUVUE(®) TrueEye™ and ACUVUE OASYS(®) contact lenses by incorporating vitamin E diffusion barriers. Results show that 20% of vitamin E loading in the contact lens increases the release duration of levofloxacin to 100 h and 50 h from 1-DAY ACUVUE(®) TrueEye™ and ACUVUE OASYS(®), respectively, which is a 3- and 6-fold increase, respectively, for the 2 lenses. For chlorhexidine, the increase is 2.5- and 10-fold, for the TrueEye™ and OASYS(®), respectively, to 130 h and 170 h. The mass of drug loaded in the lenses can be controlled to achieve a daily release comparable to the commonly prescribed eye drop therapy. The vitamin E-loaded lenses retain all critical properties for in vivo use. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Tonopen XL assessment of intraocular pressure through silicone hydrogel contact lenses.
Schornack, Muriel; Rice, Melissa; Hodge, David
2012-09-01
To assess the accuracy of Tonopen XL measurement of intraocular pressure (IOP) through low-power (-0.25 to -3.00) and high power (-3.25 to -6.00) silicone hydrogel lenses of 3 different materials (galyfilcon A, senofilcon A, and lotrafilcon B). Seventy-eight patients were recruited for participation in this study. All were habitual wearers of silicone hydrogel contact lenses, and none had been diagnosed with glaucoma, ocular hypertension, or anterior surface disease. IOP was measured with and without lenses in place in the right eye only. Patients were randomized to initial measurement either with or without the lens in place. A single examiner collected all data. No statistically significant differences were noted between IOP measured without lenses and IOP measured through low-power lotrafilcon B lenses or high-power or low-power galyfilcon A and senofilcon A lenses. However, we did find a statistically significant difference between IOP measured without lenses and IOP measured through high-power lotrafilcon B lenses. In general, Tonopen XL measurement of IOP through silicone hydrogel lenses may be sufficiently accurate for clinical purposes. However, Tonopen XL may overestimate IOP if performed through a silicone hydrogel lens of relatively high modulus.
Design and development of novel bandages for compression therapy.
Rajendran, Subbiyan; Anand, Subhash
2003-03-01
During the past few years there have been increasing concerns relating to the performance of bandages, especially their pressure distribution properties for the treatment of venous leg ulcers. This is because compression therapy is a complex system and requires two or multi-layer bandages, and the performance properties of each layer differs from other layers. The widely accepted sustained graduated compression mainly depends on the uniform pressure distribution of different layers of bandages, in which textile fibres and bandage structures play a major role. This article examines how the fibres, fibre blends and structures influence the absorption and pressure distribution properties of bandages. It is hoped that the research findings will help medical professionals, especially nurses, to gain an insight into the development of bandages. A total of 12 padding bandages have been produced using various fibres and fibre blends. A new technique that would facilitate good resilience and cushioning properties, higher and more uniform pressure distribution and enhanced water absorption and retention was adopted during the production. It has been found that the properties of developed padding bandages, which include uniform pressure distribution around the leg, are superior to existing commercial bandages and possess a number of additional properties required to meet the criteria stipulated for an ideal padding bandage. Results have indicated that none of the mostly used commercial padding bandages provide the required uniform pressure distribution around the limb.
Pterygium removal using a polyethylene glycol hydrogel adherent ocular bandage.
Hirst, Lawrence W
2013-06-01
To describe the result of using a polyethylene glycol hydrogel contact lens (ReSure; Ocular Therapeutix, Inc, Bedford, MA) as a protective bandage over denuded areas of Tenons after pterygium removal. Five sequential patients underwent pterygium removal with a conjunctival autograft and painting of bare Tenons in the area of the graft retrieval with a biodegradable polymer, and these patients were followed for 1 year for immediate postoperative pain, epithelial healing, and long-term conjunctival scarring. All patients showed prolonged persistence of the polymer for up to 8 to 10 weeks with resultant increased conjunctival inflammation and scarring with no evidence of decreased postoperative pain. This hydrogel polymer seems to cause prolonged inflammation and resultant scarring when used over extended areas of Tenons, and it has no role in reducing pain after pterygium surgery.
Morgan, Philip B; Chamberlain, Paul; Moody, Kurt; Maldonado-Codina, Carole
2013-06-01
To evaluate the performance of a silicone hydrogel daily disposable lens in neophyte subjects over 12 months. Seventy four subjects with no previous contact lens experience were randomised to wear narafilcon A (1 DAY ACUVUE(®) TruEye™) lenses (LW group) or to wear no contact lenses (NLW group) for 12 months. Biomicroscopy (performed by a masked investigator), visual acuity and subjective response scores were recorded at an initial visit and six follow-up visits, in addition to lens fit and surface evaluation for the LW group. Comfort was recorded with SMS messaging. Fifteen of the LW group discontinued before the end of the study, compared with six of the NLW group. Measured visual acuity was about half a line better for the NLW group as these subjects were provided with their full sphero-cylindrical over-refraction, compared to the LW group in their best spherical corrected contact lenses; subjective scores for vision were similar for the two groups. Bulbar conjunctival hyperaemia, limbal hyperaemia, corneal staining, conjunctival staining and papillary conjunctivitis were clinically equivalent for the two groups whereas conjunctival staining was higher in the LW group. Comfort scores assessed by SMS were equivalent for the LW and NLW groups; there was a measurable improvement in comfort during the first month of wear for the LW group. This work has demonstrated that modern soft lenses (narafilcon A daily disposable silicone hydrogel lenses) offer an excellent, comfortable form of vision correction, and are able to exhibit minimal alterations to ocular physiology. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Raali, E; Vaahtoranta-Lehtonen, H H; Lehtonen, O P
2001-07-01
BEN22 detergent was studied for its ability to detach Acanthamoeba from soft contact lenses without mechanical cleaning or separate cleaning agents. Trophozoites of Acanthamoeba castellanii and A. polyphaga were adhered onto nonionic, high water content soft contact lenses. The lenses were immersed for 2 hours in contact lens care solutions and the remaining trophozoites were counted microscopically. The counts were compared to the counts on the same lens before treatment. BEN22 (50:50 mixture of L-alpha-L-rhamnopyranosyl-beta-hydroxydecanoyl-beta-hydroxydecanoate and 2-O-alpha-L-rhamnopyranosyl-alpha-L-rhamnopyranosyl-beta-hydroxydecanoyl-beta-hydroxydecanoate) (Kassell Industries, Inc., Wisconsin Dells, WI) in a concentration of 0.05% detached the trophozoites to a statistically significant greater extent than saline, but commercial ReNu Multi-Purpose Solution (Bausch & Lomb, Italy) and BioSoak (Finnsusp Ltd., Finland) did so as well. ReNu Multi-Purpose Solution was more effective than 0.005% BEN22 in detaching the trophozoites of both of the Acanthamoeba strains. After the 2 hour immersion period, a maximum of 97% of the initial trophozoites were detached. The variation between individual lenses was significantly greater than that within the different areas of one lens. BEN22 had no reliable detaching effect on Acanthamoeba. The variation between lenses was great, and the rate of detachment was low with all the agents tested indicating that immersion and rinsing in the solutions tested cannot be considered as a safe substitute for proper disinfection against Acanthamoeba in contact lens care.
Mowrey-McKee, Mary; Borazjani, Roya; Collins, Gary; Cook, James; Norton, Susan
2012-01-01
The purpose of this article is to describe new methodology, antimicrobial efficacy endpoint methodology to determine compatibility of contact lens solutions, lens cases and hydrogel lenses for disinfection (AEEMC), to evaluate the effect of a contact lens and a lens case on disinfection efficacy, and to present the ring test used to justify the use of the method in multiple laboratories. A prototype solution containing chlorhexidine as the disinfecting agent and four representative lens types (group I and IV hydrogels and two silicone hydrogels) were used in these ring tests. Five laboratories participated in the chemical and microbiologic analyses. The residual chlorhexidine in lens cases containing the contact lenses was determined using high-performance liquid chromatography; uptake by the lenses was then determined by extrapolation. For the microbiologic part of the study, a contact lens was placed in the well of the lens case, inoculated at 10 to 10 cfu (colony forming units) per lens with microorganisms in 10% organic soil. The microorganisms, Pseudomonas aeruginosa, Serratia marcescens, Staphylococcus aureus, Candida albicans, and Fusarium solani, were prepared as in International Organization for Standardization (ISO) 14729. After a 3- to 10-min exposure time, the prototype solution was dispensed into each well. Aliquots of the inoculated solutions were removed at 4 and 24 hrs and 7 and 30 days and cultured in neutralizing media for determination of survivors; lenses were also cultured for survivors. Chemical uptake data confirmed the differences observed in kill of the challenge organisms according to lens type. It was observed that the culturing of the solution provided adequate data to show the effect of a lens on disinfection efficacy of a lens care product. The findings of the ring test indicated that the separate culturing of the contact lenses is not necessary for routine assessment. The methodology in the November 12, 2008, draft standard (AEEMC), meets the stated objective of demonstrating the effect of a contact lens on the disinfection efficacy of a simulated lens care product. This method, used in combination with the methodology in ISO 14729, should provide for a more robust evaluation of applicable contact lens care disinfecting products.
To wear or not to wear: current contact lens use in the Royal Canadian Mounted Police.
Wells, G A; Brown, J J; Casson, E J; Easterbrook, M; Trottier, A J
1997-04-01
The Canadian Ophthalmological Society was asked by the Royal Canadian Mounted Police (RCMP) and the Canadian Human Rights Commission to render an opinion on the acceptability of contact lenses as a reasonable accommodation to the uncorrected visual acuity standard. Survey by mailed questionnaire. Canada. All RCMP general duty constables with a visual acuity code of V3, V4, V5 or V6 (n = 348) and a random sample of approximately 25% of the constables with an acuity code of V2 (n = 809). Of the 1040 questionnaires returned, 1037 were usable (final response rate 89.6%). Of the 1037 respondents 316 were in the V3 to V6 group and 721 were in the V2 group. Reported frequency of problems with spectacles or contact lenses, weighted according to sampling fraction. A total of 934 respondents indicated that they used some form of visual acuity correction while on duty; of the 934, 360 reported that they wore contact lenses at least some of the time. Approximately 75% of the spectacle wearers reported having to remove their spectacles because of fogging or rain. Although contact lens dislogement or fogging (21.2%) was less frequent than spectacle dislogement (59.2%), 35.4% of the contact lens wearers reported that they were unable to wear their lenses because of irritation on at least one occasion in the previous 2 years; the median length of time was 3.14 days. When the additional amount of time due to other causes is factored in, it is clear that contact lens users wear spectacles for substantial periods while on duty. Not only are RCMP general duty constables who usually wear contact lenses likely to have to wear spectacles at some time, but it is also possible that they will have to remove their spectacles and function in an uncorrected state in critical situations. Thus, altering the current standard to allow the use of contact lenses as a reasonable accommodation would not ensure effective and safe job performance.
Code of Federal Regulations, 2011 CFR
2011-07-01
... items: Gauze roller bandages, 1 inch and 2 inch. Gauze compress bandages, 4 inch. Adhesive bandages, 1 inch. Triangular bandage, 40 inch. Ammonia inhalants and ampules. Antiseptic applicators or swabs. Burn...
Rosidal K: a short-stretch compression bandage system.
Williams, C
Management of venous leg ulcers account for a large proportion of the work of healthcare professionals, especially for those who are community based. Multilayer and long-stretch bandage systems have been used successfully for many years in venous leg ulcer management. Rosidal K, a short-stretch bandage, is now also becoming more widely accepted in this country as an effective and cost-effective bandage system. This product focus looks at bandage systems and examines the research supporting the use of short-stretch bandages and Rosidal K.
Michaud, Langis; Bennett, Edward S; Woo, Stephanie L; Reeder, Renee; Morgan, Bruce W; Dinardo, Amy; Harthan, Jennifer S
2018-05-01
This study aims to address the clinical performance of a large diameter rigid gas permeable lens (LRGP) in a group of subjects with low-to-moderate (0.75-2.75 D) refractive astigmatism. An additional goal was to determine whether soft toric or LRGP contact lenses performed better objectively in the correction of astigmatism and to determine which modality is preferred by subjects. This was a multisite prospective cross-over clinical study. Ten asymptomatic contact lens wearers per site (four university clinics) were recruited and randomly assigned to group A or group B. Group A was assigned to start wearing Comfilcon A soft toric lens first, for two weeks, and then crossed over to LRGP lenses (Boston XO, 14.3 mm diameter miniscleral lens). Group B initially wore LRGP lenses and then crossed over to soft toric lenses. For each type of lens worn, low-contrast and high-contrast visual acuity (VA) were evaluated at distance. At the conclusion of the study, after two months, all subjects completed a questionnaire in which they were asked to indicate their preference for one type of lens (soft toric or LRGP) and to rate the quality of vision in day-to-day activities. Thirty-six of 38 (94.7%) subjects completed the study with 75% preferring the vision of the LRGP lens as compared to the soft toric lenses worn in the study. 52.7% expressed a preference to continue with this modality despite only 38.8% reporting that these LRGP lenses are easy or very easy to handle. Wear time, subjective comfort, and subjective vision ratings exhibited no significant difference between the two groups. In a population of asymptomatic contact lens wearers, LRGP lenses can be considered as a good alternative to soft toric lenses for the correction of refractive astigmatism.
Does correcting astigmatism with toric lenses improve driving performance?
Cox, Daniel J; Banton, Thomas; Record, Steven; Grabman, Jesse H; Hawkins, Ronald J
2015-04-01
Driving is a vision-based activity of daily living that impacts safety. Because visual disruption can compromise driving safety, contact lens wearers with astigmatism may pose a driving safety risk if they experience residual blur from spherical lenses that do not correct their astigmatism or if they experience blur from toric lenses that rotate excessively. Given that toric lens stabilization systems are continually improving, this preliminary study tested the hypothesis that astigmats wearing toric contact lenses, compared with spherical lenses, would exhibit better overall driving performance and driving-specific visual abilities. A within-subject, single-blind, crossover, randomized design was used to evaluate driving performance in 11 young adults with astigmatism (-0.75 to -1.75 diopters cylinder). Each participant drove a highly immersive, virtual reality driving simulator (210 degrees field of view) with (1) no correction, (2) spherical contact lens correction (ACUVUE MOIST), and (3) toric contact lens correction (ACUVUE MOIST for Astigmatism). Tactical driving skills such as steering, speed management, and braking, as well as operational driving abilities such as visual acuity, contrast sensitivity, and foot and arm reaction time, were quantified. There was a main effect for type of correction on driving performance (p = 0.05). Correction with toric lenses resulted in significantly safer tactical driving performance than no correction (p < 0.05), whereas correction with spherical lenses did not differ in driving safety from no correction (p = 0.118). Operational tests differentiated corrected from uncorrected performance for both spherical (p = 0.008) and toric (p = 0.011) lenses, but they were not sensitive enough to differentiate toric from spherical lens conditions. Given previous research showing that deficits in these tactical skills are predictive of future real-world collisions, these preliminary data suggest that correcting low to moderate astigmatism with toric lenses may be important to driving safety. Their merits relative to spherical lens correction require further investigation.
Lui, Aline Cristina Fioravanti; Netto, Adamo Lui; Silva, Cely Barreto da; Hida, Richard; Mendes, Thais Sousa; Lui, Giovana Arlene Fioravanti; Gemperli, Daniela Barbosa; Vital, Enderson Dantas
2009-01-01
To evaluate the efficacy of disinfecting solutions in hydrophilic contact lenses (CL). Two multi-use solutions denominated solution A (0.001% polyquaternium-1 and 0.0005% myristamidopropyl dimethylamine) and solution B (0.0001% polyaminopropyl biguanide) were used. The solutions were tested in hydrophilic contact lenses infected with Pseudomonas aeruginosa (ATCC27583), Staphylococcus epidermidis (ATCC1226), Klebsiella pneumoniae (ATCC13883), Staphylococcus aureus (ATCC25923) and Candida albicans (ATCC 10231) and the decrease in microorganisms growth after the hydrophilic contact lenses were cleaned with the respective solutions was verified. The manufacture's instructions were followed. A decrease of 90% of Pseudomonas aeruginosa, Staphylococcus epidermidis, Staphylococcus aureus, Candida albicans and a decrease 100% of Klebsiella pneumoniae was observed. The solutions decreased the amount of microorganisms tested.
Microbial adherence to cosmetic contact lenses.
Chan, Ka Yin; Cho, Pauline; Boost, Maureen
2014-08-01
To investigate whether cosmetic contact lenses (CCL) with surface pigments affect microbial adherence. Fifteen brands of CCL were purchased from optical, non-optical retail outlets, and via the Internet. A standardized rub-off test was performed on each CCL (five lenses per brand) to confirm the location of the pigments. The rub-off test comprised gentle rubbing on the surfaces of each CCL with wetted cotton buds for a maximum of 20 rubs per surface. A new set of CCL (five lenses per brand) were incubated in Pseudomonas aeruginosa overnight. Viable counts of adhered bacteria were determined by the number of colony-forming units (CFU) on agar media on each lens. The adherence of P. aeruginosa as well as Staphylococcus aureus and Serratia marcescens to three brands of CCL (A-C) (five lenses per brand) were also compared to their adherences on their clear counterparts. Only two of the 15 brands of CCL tested (brands B and C) had pigments that did not detach with the rub-off test. The remaining 13 brands of CCL all failed the rub-off test and these lenses showed higher P. aeruginosa adherence (8.7 × 10(5)-1.9 × 10(6) CFU/lens). Brands B and C lenses showed at least six times less bacterial adhesion than the other 13 brands. Compared to their clear counterparts, bacterial adherence to brands B and C lenses did not differ significantly, whereas brand A lenses showed significantly higher adherence. Surface pigments on CCL resulted in significantly higher bacterial adherence. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Zhu, Qiang; Cheng, Hongbo; Huo, Yingnan; Mao, Shirui
2018-06-10
In the present work the feasibility of using inner layer-embedded contact lenses (CLs) to achieve sustained release of highly water soluble drug, betaxolol hydrochloride (BH) on the ocular surface was investigated. Blend film of cellulose acetate and Eudragit S100 was selected as the inner layer, while silicone hydrogel was used as outer layer to construct inner layer-embedded contact lenses. Influence of polymer ratio in the blend film on in vitro drug release behavior in phosphate buffered solution or simulated tear fluid was studied and drug-polymer interaction, erosion and swelling of the blend film were characterized to better understand drug-release mechanism. Storage stability of the inner layer-embedded contact lenses in phosphate buffer solution was also conducted, with ignorable drug loss and negligible change in drug release pattern within 30 days. In vivo pharmacokinetic study in rabbits showed sustained drug release for over 240 h in tear fluid, indicating prolonged drug precorneal residence time. In conclusion, cellulose acetate/Eudragit S100 inner layer-embedded contact lenses are quite promising as controlled-release carrier of highly water soluble drug for ophthalmic delivery. Copyright © 2018 Elsevier B.V. All rights reserved.
Multi-layer compression: comparison of four different four-layer bandage systems applied to the leg.
Dale, J J; Ruckley, C V; Gibson, B; Brown, D; Lee, A J; Prescott, R J
2004-01-01
To compare performance of four commercial four-layer bandage systems when applied to the leg. Four experienced bandagers applied each system: [Profore Regular (Smith and Nephew); Ultra-Four (Robinson); System 4 (Seton) and K Four (Parema)] to the same leg. Bandages were applied as single layers and as completed systems using standard techniques. For each application, 18 pressure measurements were taken using the Borgnis Medical Stocking Tester (MST) at three measuring points (ankle, gaiter and mid-calf) on medial and lateral aspects in three postures: (horizontal, standing and sitting). In all 2304 observations were made, 576 for each bandager, 576 for each bandaging system, 768 for each measuring point, 1152 for each aspect and 768 for each posture. The increase in pressure produced by each additional layer was 65-75% of the pressure of the same bandage when used as a single layer. There were significant differences in the final pressures achieved by the bandagers (means: 45-54 mmHg, p<0.001) and between bandage systems (means: System 4: 46 mmHg, Profore: 47 mmHg, K Four: 52 mmHg, Ultra-Four: 54 mmHg; p=0.005). The relationships between the final pressures achieved at each of the three measuring points, the three postures and the two aspects were not consistent among the bandage systems (p<0.01). When a bandage is applied as part of a multi-layered system it exerts approximately 70% of the pressure exerted when applied alone, thus challenging the commonly-held assumption that the final pressure achieved by a multi-layer bandaging system is the sum of the pressures exerted by each individual layer. Each of the four bandaging systems exerted different final pressures and gradients and different changes with posture change. These differences have important implications, which could influence the selection (or avoidance) of a particular bandage system according to a patient's condition and circumstances.
Lohmann, C P; Fitzke, F W; O'Brart, D; Muir, M K; Marshall, J
1993-01-01
After photorefractive keratectomy (PRK) using excimer lasers (193 nm) many patients report the presence of halos around light sources at night. However, halos are not unique to PRK patients, as they are a common observation in myopic contact lens wearers. We present an objective measurement of the halos using a computerized technique. The patient fixated on a red cross within a white circle in the center of a video monitor which served as the halo source. The screen surrounding the circle was not illuminated. The operator controlled the movement of the white spot and moved the spot toward the halo source until the subject indicated when the cursor was at the outer parameter of the halo. Measurements were made at 30 degree intervals around the halo source and expressed as square degrees. The study found that spectacles, soft contact lenses, and excimer laser surgery were superior to hard contact lenses in terms of the size of the halo. A mean value of 2.51 square degrees was obtained for spectacles wearers compared with 3.18 square degrees for soft contact lenses, 3.14 square degrees for excimer laser patients with 4-millimeter ablation zone, 2.76 square degrees for excimer laser patients with a 5-millimeter ablation zone, and 89.5 square degrees for hard contact lenses. It appears that this device is very useful for measuring the halo size after excimer laser PRK. We concluded that halos were not a problem for our patients after excimer laser photorefractive keratectomy.
Consequences of wear interruption for discomfort with contact lenses.
Papas, Eric B; Tilia, Daniel; Tomlinson, Daniel; Williams, Josh; Chan, Eddy; Chan, Jason; Golebiowski, Blanka
2014-01-01
To establish whether increased end-of-day discomfort during soft contact lens wear is associated with short-term changes occurring to the lens itself. Twenty-seven subjects wore hydrogel lenses (Focus Dailies; Alcon) bilaterally for 10 hours on two separate days. Comfort was reported using 1-100 numerical rating scales (1 = intolerable discomfort, 100 = lens cannot be felt). Day 1 ratings were taken before lens insertion and at 0.05, 5, and 10 hours post-insertion. Day 2 ratings occurred at similar times, but lenses were removed after the 5-hour assessment and either reinserted (n = 14) or newly replaced (n = 12). An additional rating was taken 5 minutes after re-insertion. Wear then continued to the 10-hour point. In a separate study, 24 different subjects repeated these procedures using a silicone hydrogel lens (AirOptix Aqua; Alcon) with wear taking place on 3 days to permit lens replacement to be with existing as well as new lenses in all subjects. For hydrogel lenses, comfort scores (mean ± 95% CI) reported after 10 hours were 79.4 ± 8.3 when lenses were worn un-replaced, compared with 73.2 ± 9.2 for replacement with the existing lens. When replacement was with a brand new lens, the corresponding values were 72.9 ± 10.9 (un-replaced) versus 69.2 ± 12.8 (new lens replacement). For silicone hydrogel lenses, 10-hour comfort was 90.3 ± 3.2 (un-replaced) versus 92.2 ± 2.9 (replacement with existing lens) versus 90.0 ± 3.3 (replacement with new lens). Differences between replacement conditions were not significant in any case (analysis of variance, p > 0.05). Final comfort was not influenced by replacing lenses midway through the wearing period. Comfort decrements experienced by users of these daily contact lenses towards the later part of the wearing period are not caused by changes occurring to the lenses on this time scale. Possible alternative etiological factors include a fatigue-like response in one or more ocular tissues or stimulation of ocular surface nociceptors induced by the presence of the contact lens.
Moffatt, Christine J; McCullagh, Lynn; O'Connor, Theresa; Doherty, Debra C; Hourican, Catherine; Stevens, Julie; Mole, Trevor; Franks, Peter J
2003-01-01
To compare a four-layer bandage system with a two-layer system in the management of chronic venous leg ulceration, a prospective randomized open parallel groups trial was undertaken. In total, 112 patients newly presenting to leg ulcer services with chronic leg ulceration, screened to exclude the presence of arterial disease (ankle brachial pressure index <0.8) and causes of ulceration other than venous disease, were entered into the trial. Patients were randomized to receive either four-layer (Profore) or two-layer (Surepress) high-compression elastic bandage systems. In all, 109 out of 112 patients had at least one follow-up. After 24 weeks, 50 out of 57 (88%) patients randomized to the four-layer bandage system with follow-up had ulcer closure (full epithelialization) compared with 40 out of 52 (77%) on the two-layer bandage, hazard ratio = 1.18 (95% confidence interval 0.69-2.02), p = 0.55. After 12 weeks, 40 out of 57 (70%) patients randomized to the four-layer bandage system with follow-up had ulcer closure compared with 30 out of 52 (58%) on the two-layer bandage, odds ratio = 4.23 (95% confidence interval 1.29-13.86), p = 0.02. Withdrawal rates were significantly greater on the two-layer bandage (30 out of 54; 56%) compared with the four-layer bandage system (8 out of 58; 14%), p < 0.001, and the number of patients with at least one device-related adverse incident was significantly greater on the two-layer bandaging system (15 out of 54; 28%) compared with four-layer bandaging (5 out of 54; 9%), p = 0.01. The higher mean cost of treatment in the two-layer bandaging system arm over 24 weeks ($1374 [ pound 916] vs. $1314 [ pound 876]) was explained by the increased mean number of bandage changes (1.5 vs. 1.1 per week) with the two-layer system. In conclusion, the four-layer bandage offers advantages over the two-layer bandage in terms of reduced withdrawal from treatment, fewer adverse incidents, and lower treatment cost.
Shoff, Megan E; Lucas, Anne D; Brown, Jennifer N; Hitchins, Victoria M; Eydelman, Malvina B
2012-11-01
To determine the effect of 8 different lens materials on polyhexamethylene biguanide (PHMB) concentration in multipurpose solution (MPS) levels over time and to determine the effect of lenses on lens solution microbial efficacy over time. Silicone hydrogel lenses and conventional hydrogel lenses were soaked in polypropylene lens cases filled with contact lens MPS containing 1 ppm PHMB for 6, 12, 24, 72, and 168 hours. Cases filled with the same solution without lenses were controls. After each time period, solutions from cases with the 8 types of lenses and controls were assayed for activity against Staphylococcus aureus according to International Organization for Standardization-14729 with modifications. Solutions were analyzed for PHMB concentration at each time point. Some of the different lens materials significantly affected the PHMB concentration (P<0.0001) and the biocidal efficacy. Etafilcon A lenses significantly decreased PHMB levels after only 6 hours of lens soak time. The product lot of MPS used was also significant (P<0.0001). Enfilcon A, senofilcon A, and lotrafilcon B lenses did not significantly decrease PHMB levels. The efficacy of MPS was affected by some lens materials and PHMB concentration. Lens materials differ in their effect on PHMB concentration and the subsequent efficacy of the MPS. Over time, some lens materials can significantly reduce the PHMB concentration and the MPS's microbial activity against S. aureus.
Drug delivery to the posterior segment of the eye through hydrogel contact lenses.
Schultz, Clyde; Breaux, Jason; Schentag, Jerome; Morck, Douglas
2011-03-01
Despite pharmacological advances, delivery of drugs to the posterior segment of the eye remains problematic. We investigated the ability of hydrogel contact lenses to deliver small-molecule steroids, as well as larger biological molecules to the posterior segment. Release characteristics of steroid-instilled lenses were studied in vitro. Drug delivery to the posterior segment of the eye was evaluated in a rabbit model, in which hydrogel contact lenses treated with diluted steroids (prednisolone or beclomethasone) were placed on rabbit corneas for four hours on days 1, 2, 5, 8 and 10. The amount of drug in plasma, posterior segment tissue and vitreous humour was measured with high-performance liquid chromatography-tandem mass spectrometry. In a further preliminary investigation, two rabbits were treated with ranibizumab. The lenses released prednisolone and beclomethasone in saline over a six-hour period at a declining rate. Prednisolone was found in posterior segment tissue from six of six rabbits at concentrations ranging from 26.8 to 166 ng/g and in vitreous humour from two of six rabbits. Beclomethasone was detected in posterior segment tissue from three rabbits but was not found in the vitreous humour. Ranibizumab was detected in posterior segment tissue in a range from 0.19 ng/mL to 0.5183 ng/mL. Hydrogel contact lenses are a non-invasive, periocular drug delivery device capable of achieving measurable drug levels in posterior segment tissue. © 2010 The Authors. Clinical and Experimental Optometry © 2010 Optometrists Association Australia.
Szczotka-Flynn, Loretta B.; Imamura, Yoshifumi; Chandra, Jyotsna; Yu, Changping; Mukherjee, Pranab K.; Pearlman, Eric; Ghannoum, Mahmoud A.
2014-01-01
PURPOSE To determine if clinical and reference strains of Pseudomonas aeruginosa, Serratia marcescens, and Staphylococcus aureus form biofilms on silicone hydrogel contact lenses, and ascertain antimicrobial activities of contact lens care solutions. METHODS Clinical and American Type Culture Collection (ATCC) reference strains of Pseudomonas aeruginosa, Serratia marcescens, and Staphylococcus aureus were incubated with lotrafilcon A lenses under conditions that facilitate biofilm formation. Biofilms were quantified by quantitative culturing (colony forming units, CFUs), and gross morphology and architecture were evaluated using scanning electron microscopy (SEM) and confocal microscopy. Susceptibilities of the planktonic and biofilm growth phases of the bacteria to five common multipurpose contact lens care solutions and one hydrogen peroxide care solution were assessed. RESULTS P. aeruginosa, S. marcescens, and S. aureus reference and clinical strains formed biofilms on lotrafilcon A silicone hydrogel contact lenses, as dense networks of cells arranged in multiple layers with visible extracellular matrix. The biofilms were resistant to commonly used biguanide preserved multipurpose care solutions. P. aeruginosa and S. aureus biofilms were susceptible to a hydrogen peroxide and a polyquaternium preserved care solution, whereas S. marcescens biofilm was resistant to a polyquaternium preserved care solution but susceptible to hydrogen peroxide disinfection. In contrast, the planktonic forms were always susceptible. CONCLUSIONS P. aeruginosa, S. marcescens, and S. aureus form biofilms on lotrafilcon A contact lenses, which in contrast to planktonic cells, are resistant to the antimicrobial activity of several soft contact lens care products. PMID:19654521
Golebiowski, Blanka; Papas, Eric B; Stapleton, Fiona
2012-03-09
Deprivation of oxygen to the ocular surface during contact lens wear has been implicated in the alteration of sensory function. This study investigates whether increasing oxygen availability through discontinuation of contact lens wear or transfer into highly oxygen transmissible (high Dk/t) lenses leads to a change in corneal or conjunctival sensitivity. Twenty-seven long-term extended wearers of low Dk/t soft contact lenses ceased lens wear for 1 week and were refitted with high Dk/t silicone hydrogel lenses. A control group of 25 nonwearers matched for age and sex was also recruited. Central corneal and inferior conjunctival sensitivity were measured using an air-jet aesthesiometer. Threshold was determined using a staircase technique. Measurements were taken during low Dk/t lens wear; after 1 week of no wear; and after 1, 3, 6, and 12 months of high Dk/t lens wear. Measurements were carried out on one occasion on the nonwearers. Corneal sensitivity decreased 1 week after discontinuation of low Dk/t lenses and no further change in sensitivity occurred with high Dk/t lens wear. Conjunctival sensitivity did not change over the same time frame. Ocular surface sensitivity in long-term low Dk/t soft lens wearers was similar to that of nonwearers. Sensitivity was higher in females than males in the nonwearers, but not in the lens-wearing group. An interaction of sex on change in conjunctival threshold was found in the lens wearers. These findings indicate that factors other than oxygen availability alone determine sensitivity of the ocular surface. Silicone hydrogel contact lenses appear to have only a minor impact on ocular surface sensitivity in previous lens wearers.
Which soft contact lens power is better for piggyback fitting in keratoconus?
Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose Manuel
2013-02-01
To evaluate the impact of differente soft contact lens power in the anterior corneal curvature and regularity in subjects with keratoconus. Nineteen subjects (30 eyes) with keratoconus were included in the study. Six corneal topographies were taken with Pentacam Eye System over the naked eye and successively with soft lens (Senofilcon A) powers of -3.00, -1.50, 0.00, +1.50 and +3.00 D. Corneal measurements of mean central keratometry (MCK), maximum tangential curvature (TK), maximum front elevation (MFE) and eccentricity (Ecc) at 6 and 8 mm diameters as well as anterior corneal surface high order aberrations (i.e. total RMS, spherical- and coma-like and secondary astigmatism) were evaluated. Negative- and plano-powered soft lenses flattened (p<0.05 in all cases), whereas positive-powered lenses did not induce any significant changes (p>0.05 in all cases) in MCK in comparison to the naked eye. The TK power decreased with negative lenses (p<0.05 in both cases) and increased with +3.00 D lenses (p=0.03) in comparison to the naked eye. No statistically significant differences were found in MFE with any soft lens power in comparison to the naked eye (p>0.05 in all cases). Corneal eccentricity increased at 8 mm diameter for all lens powers (p<0.05 in all cases). No statistically differences were found in HOA RMS and spherical-like aberration (both p>0.05). Statistically differences were found in coma-like and secondary astigmatism (both p<0.05). Negative-powered soft contact lenses provide a flatter anterior surface in comparison to positive-powered lenses in subjects with keratoconus and thus they might be more suitable for piggyback contact lens fitting. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Pressure mapping and performance of the compression bandage/garment for venous leg ulcer treatment.
Ghosh, S; Mukhopadhyay, A; Sikka, M; Nagla, K S
2008-08-01
A study has been conducted on the commercially available compression bandages as regards their performance with time. Pressure mapping of these bandages has been done using a fabricated pressure-measuring device on a mannequin leg to see the effect on pressure due to creep, fabric friction and angle of bandaging. The results show that the creep behavior, frictional behavior and the angle of bandaging have a significant effect on the pressure profile generated by the bandages during application. The regression analysis shows that the surface friction restricts the slippage in a multilayer system. Also the diameters of the limb and the amount of stretch given to the bandage during application have definite impact on the bandage pressure. In case of compression garments, washing improves the pressure generated but not to the extent of the pressure of a virgin garment. Comparing the two compression materials i.e. bandage and garment, it is found that the presence of higher percentage of elastomeric material and a highly close construction in case of garment provides better holding power and a more homogeneous pressure distribution.
Studies of a new multi-layer compression bandage for the treatment of venous ulceration.
Scriven, J M; Bello, M; Taylor, L E; Wood, A J; London, N J
2000-03-01
This study aimed to develop an alternative graduated compression bandage for the treatment of venous leg ulcers. Alternative bandage components were identified and assessed for optimal performance as a graduated multi-layer compression bandage. Subsequently the physical characteristics and clinical efficacy of the optimal bandage combination was prospectively examined. Ten healthy limbs were used to develop the optimal combination and 20 limbs with venous ulceration to compare the physical properties of the two bandage types. Subsequently 42 consecutive ulcerated limbs were prospectively treated to examine the efficacy of the new bandage combination. The new combination produced graduated median (range) sub-bandage pressures (mmHg) as follows: ankle 59 (42-100), calf 36 (27-67) and knee 35 (16-67). Over a seven-day period this combination maintained a comparable level of compression with the Charing Cross system, and achieved an overall healing rate at one year of 88%. The described combination should be brought to the attention of healthcare professionals treating venous ulcers as a possible alternative to other forms of multi-layer graduated compression bandages pending prospective, randomised clinical trials.
Lorenz, Kathrine Osborn; Kakkassery, Joseph; Boree, Danielle; Pinto, David
2014-09-01
Limbal ring (also known as 'circle') contact lenses are becoming increasingly popular, especially in Asian markets because of their eye-enhancing effects. The pigment particles that give the eye-enhancing effects of these lenses can be found on the front or back surface of the contact lens or 'enclosed' within the lens matrix. The purpose of this research was to evaluate the pigment location and surface roughness of seven types of 'circle' contact lenses. Scanning electron microscopic (SEM) analysis was performed using a variable pressure Hitachi S3400N instrument to discern the placement of lens pigments. Atomic force microscopy (Dimension Icon AFM from Bruker Nano) was used to determine the surface roughness of the pigmented regions of the contact lenses. Atomic force microscopic analysis was performed in fluid phase under contact mode using a Sharp Nitride Lever probe (SNL-10) with a spring constant of 0.06 N/m. Root mean square (RMS) roughness values were analysed using a generalised linear mixed model with a log-normal distribution. Least square means and their corresponding 95% confidence intervals were estimated for each brand, location and pigment combination. SEM cross-sectional images at 500× and 2,000× magnification showed pigment on the surface of six of the seven lens types tested. The mean depth of pigment for 1-DAY ACUVUE DEFINE (1DAD) lenses was 8.1 μm below the surface of the lens, while the remaining lens types tested had pigment particles on the front or back surface. Results of the atomic force microscopic analysis indicated that 1DAD lenses had significantly lower root mean square roughness values in the pigmented area of the lens than the other lens types tested. SEM and AFM analysis revealed pigment on the surface of the lens for all types tested with the exception of 1DAD. Further research is required to determine if the difference in pigment location influences on-eye performance. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.
Lorenz, Kathrine Osborn; Kakkassery, Joseph; Boree, Danielle; Pinto, David
2014-01-01
Background Limbal ring (also known as ‘circle’) contact lenses are becoming increasingly popular, especially in Asian markets because of their eye-enhancing effects. The pigment particles that give the eye-enhancing effects of these lenses can be found on the front or back surface of the contact lens or ‘enclosed’ within the lens matrix. The purpose of this research was to evaluate the pigment location and surface roughness of seven types of ‘circle’ contact lenses. Methods Scanning electron microscopic (SEM) analysis was performed using a variable pressure Hitachi S3400N instrument to discern the placement of lens pigments. Atomic force microscopy (Dimension Icon AFM from Bruker Nano) was used to determine the surface roughness of the pigmented regions of the contact lenses. Atomic force microscopic analysis was performed in fluid phase under contact mode using a Sharp Nitride Lever probe (SNL-10) with a spring constant of 0.06 N/m. Root mean square (RMS) roughness values were analysed using a generalised linear mixed model with a log-normal distribution. Least square means and their corresponding 95% confidence intervals were estimated for each brand, location and pigment combination. Results SEM cross-sectional images at 500× and 2,000× magnification showed pigment on the surface of six of the seven lens types tested. The mean depth of pigment for 1-DAY ACUVUE DEFINE (1DAD) lenses was 8.1 μm below the surface of the lens, while the remaining lens types tested had pigment particles on the front or back surface. Results of the atomic force microscopic analysis indicated that 1DAD lenses had significantly lower root mean square roughness values in the pigmented area of the lens than the other lens types tested. Conclusions SEM and AFM analysis revealed pigment on the surface of the lens for all types tested with the exception of 1DAD. Further research is required to determine if the difference in pigment location influences on-eye performance. PMID:24689948
NASA Astrophysics Data System (ADS)
Topakova, Anastassia A.; Salmin, Vladimir V.; Gar'kavenko, Victor V.; Levchenko, Julia S.; Lazarenko, Victor I.
2016-04-01
Fluorimetry of eye is a perspective technique for research and diagnostics in ophthalmology. It is connected to the structural and functional characteristics of eye that is, actually, the optical system allowing transferring the radiation both for excitation and for registration of fluorescence in different eye's compartments: cornea, lens, vitreous body, and fundus of the eye. At present, different models of ophthalmologic fluorophotometers for the analysis of eye fluorescence as well as more advanced models - scanning fluorophotometers - are offered. Assessment of corneal status in persons wearing contact lenses or in patients with pathological changes (i.e. diabetes mellitus) would give us an opportunity to identify the initial manifestations of corneal pathology at the pre-symptomatic phase. In this paper, we present data on the compact spectrofluorimeter with UV LEDs-induced excitation as well as the method for assessing hypoxic alterations in the eye limb zone caused by contact lenses wearing. We demonstrate dependence of autofluorescence spectra on the contact lenses types and duration of their permanent wearing.
Platelet lysate and chondroitin sulfate loaded contact lenses to heal corneal lesions.
Sandri, Giuseppina; Bonferoni, Maria Cristina; Rossi, Silvia; Delfino, Alessio; Riva, Federica; Icaro Cornaglia, Antonia; Marrubini, Giorgio; Musitelli, Giorgio; Del Fante, Claudia; Perotti, Cesare; Caramella, Carla; Ferrari, Franca
2016-07-25
Hemoderivative tear substitutes contain various ephiteliotrophic factors, such as growth factors (GF), involved in ocular surface homeostasis without immunogenic properties. The aim of the present work was the loading of platelet lysate into contact lenses to improve the precorneal permanence of platelet lysate growth factors on the ocular surface to enhance the treatment of corneal lesions. To this purpose, chondroitin sulfate, a sulfated glycosaminoglycan, which is normally present in the extracellular matrix, was associated with platelet lysate. In fact, chondroitin sulfate is capable of electrostatic interaction with positively charged growth factors, in particular, with bFGF, IGF, VEGF, PDGF and TGF-β, resulting in their stabilization and reduced degradation in solution. In the present work, various types of commercially available contact lenses have been loaded with chondroitin sulfate or chondroitin sulfate in association with platelet lysate to achieve a release of growth factors directly onto the corneal surface lesions. One type of contact lenses (PureVision(®)) showed in vitro good proliferation properties towards corneal cells and were able to enhance cut closure in cornea constructs. Copyright © 2016 Elsevier B.V. All rights reserved.
Legal responsibilities when fitting minors with contact lenses.
Harris, M G
2000-02-01
Practitioners must understand their legal responsibilities in fitting minors with contact lenses, which include informed consent, contractual obligations, and the Statute of Limitations. Minors are children and teenagers who have not yet reached voting age in their state--generally 18 years of age. Informed consent requires permission from the patient before a practitioner performs any treatment. For these young people, this consent generally can only be given by a parent or legal guardian. Minors can repudiate contracts made with them; therefore, the contractual obligation to pay for a contact lens fitting should be established with a parent or legal guardian. In most states, minors have additional time beyond the usual Statute of Limitations to bring a lawsuit. If practitioners recognize their legal responsibilities in caring for these special patients, fitting youngsters with contact lenses can be a rewarding part of practice.
How Could Contact Lens Wearers Be at Risk of Acanthamoeba Infection? A Review
Ibrahim, Youhanna W.; Boase, David L.; Cree, Ian A.
2010-01-01
Contact lens wear is highly influential on the incidence of ulcerative keratitis worldwide, particularly in developed countries. The association between Acanthamoeba keratitis and contact lens wear is firmly established; it may account for up to 95% of the reported cases. Before the popularisation of soft contact lens wear, Acanthamoeba keratitis was extremely rare. In 2000 it was estimated that the number of contact lens wearers worldwide was about 80 million, out of whom 33 million were in the United States and 90% of them wore hydrogel soft lenses. Contact lens-related problems depend on many factors, such as lens material, wearing modality, lens hygiene, type of lens-caring solution, the degree of compliance of the lens user with lens wear and care procedures, lens overwear, sleeping in lenses, rate of changing lenses, and lens case hygiene. This paper is a thorough review of the literature aiming to highlight the role of one of the main risk factors of infectious keratitis, contact lens wear, and also to show the responsibility of lens users in aggravating this risk.
Antimicrobial Efficacy of Contact Lens Care Solutions Against Neutrophil-Enhanced Bacterial Biofilms
Hinojosa, Jorge A.; Patel, Naiya B.; Zhu, Meifang; Robertson, Danielle M.
2017-01-01
Purpose Neutrophil-derived extracellular debris has been shown to accelerate bacterial biofilm formation on hydrogel and silicone hydrogel contact lens surfaces compared to lenses inoculated with bacteria alone. The purpose of this study was to evaluate the disinfection efficacy of four standard commercial contact lens cleaning regimens against neutrophil-enhanced bacterial biofilms formed on silicone hydrogel contact lenses. Methods Four reference strains were used: Pseudomonas aeruginosa, Serratia marcescens, Stenotrophomonas maltophilia, and Staphylococcus aureus. Human neutrophils were isolated from peripheral blood by venipuncture. Unworn Lotrafilcon B lenses were incubated overnight in each respective strain with stimulated neutrophils. Contact lenses were then cleaned using one of four contact lens care solutions according to manufacturer instructions. Bacterial viability was assessed by colony counts and confocal microscopy. Volume of residual debris on lens surfaces after cleaning was quantified using IMARIS software. Results All four solutions tested showed effective antimicrobial activity against each bacterial strain; however, substantial amounts of nonviable bacteria and cellular debris remained on the lens surface despite concomitant digital cleaning. Conclusions Necrotic cellular debris that accumulates under the posterior lens surface during wear of an inoculated contact lens is not fully removed during routine cleaning and disinfection. Translational Relevance The accumulation of residual cellular debris on the contact lens surface may contribute to new colonization of the lens and represents a significant risk factor for a contact lens–related adverse event. Additional studies are needed to correlate these findings with risk for corneal infiltrative and/or infectious events in a standard animal model. PMID:28473944
The effect of fractal contact lenses on peripheral refraction in myopic model eyes.
Rodriguez-Vallejo, Manuel; Benlloch, Josefa; Pons, Amparo; Monsoriu, Juan A; Furlan, Walter D
2014-12-01
To test multizone contact lenses in model eyes: Fractal Contact Lenses (FCLs), designed to induce myopic peripheral refractive error (PRE). Zemax ray-tracing software was employed to simulate myopic and accommodation-dependent model eyes fitted with FCLs. PRE, defined in terms of mean sphere M and 90°-180° astigmatism J180, was computed at different peripheral positions, ranging from 0 to 35° in steps of 5°, and for different pupil diameters (PDs). Simulated visual performance and changes in the PRE were also analyzed for contact lens decentration and model eye accommodation. For comparison purposes, the same simulations were performed with another commercially available contact lens designed for the same intended use: the Dual Focus (DF). PRE was greater with FCL than with DF when both designs were tested for a 3.5 mm PD, and with and without decentration of the lenses. However, PRE depended on PD with both multizone lenses, with a remarkable reduction of the myopic relative effect for a PD of 5.5 mm. The myopic PRE with contact lenses decreased as the myopic refractive error increased, but this could be compensated by increasing the power of treatment zones. A peripheral myopic shift was also induced by the FCLs in the accommodated model eye. In regard to visual performance, a myopia under-correction with reference to the circle of least confusion was obtained in all cases for a 5.5 mm PD. The ghost images, generated by treatment zones of FCL, were dimmer than the ones produced with DF lens of the same power. FCLs produce a peripheral myopic defocus without compromising central vision in photopic conditions. FCLs have several design parameters that can be varied to obtain optimum results: lens diameter, number of zones, addition and asphericity; resulting in a very promising customized lens for the treatment of myopia progression.
IMPACT OF A RINSE STEP ON PROTEIN REMOVAL FROM SILICONE HYDROGEL CONTACT LENSES
Pucker, Andrew D.; Nichols, Jason J.
2010-01-01
PURPOSE To determine the impact of the rinse step in “no rub” contact lens care systems relative to its ability to assist in removing loosely associated and bound tear film proteins from a worn silicone hydrogel lens. METHODS After informed consent, subjects were fitted with lotrafilcon B contact lenses (CIBA Vision, Inc). If the fit was acceptable, subjects were asked to wear the lenses on a daily wear basis for 5 (+2, −0) days for an outcome visit. Subjects were instructed to use AQuify Multi-Purpose Disinfecting Solution (CIBA Vision, Inc) following the manufacturer's “no rub” instructions. At the outcome visit, contact lenses were then collected by a gloved examiner, with a sterile metal forceps, who rinsed the right lens but did not rinse the left lens upon removal from the eyes. Protein was extracted with a 50:50 0.2% trifluoroacetic acid-acetonitrile solution and quantified using a Bradford analyses. RESULTS Twenty contact lens wearers were enrolled in this study. For the non-rinsed lenses, the first extraction yielded 13.4 ± 9.2 µg/lens of protein, while the second extraction yielded 5.8 ± 2.8 µg/lens of protein. For the rinsed lenses, first extraction yielded an average of 3.0 ± 1.9 µg/lens of protein, while the second extraction yielded an average of 4.0 ± 2.3 µg/lens. Repeated measures ANOVA showed a significant interaction (F-statistic = 18.9, p< 0.0001) between the rinse of a lens and extraction number. CONCLUSIONS Rinsing a contact lens following removal from the eye removes well over one-half of the protein associated with it. Further, in order to biochemically recover all protein from a silicone hydrogel lens, it may be important to perform more than one chemical extraction from it. PMID:19609231
Interface pressure is affected by slippage of bandages at thigh.
Miyazaki, K; Hirai, M; Koyama, A; Iwata, H; Ohashi, M; Ota, A
2012-12-01
Very little is known about how compression bandages lose interface pressure. We hypothesized that the loss of interface pressure is correlated with the slippage of the bandages, and studied the interface pressure and slippage of three bandages over 8 hours. Twenty-Seven legs from 27 healthy volunteers were bandaged with short stretch bandages (SS), cohesive short stretch bandages (CS), and long stretch bandages (LS). Pressure sensors were placed above the ankle (B1), below the knee (D), and mid thigh (F). Interface pressures in a sitting position were recorded at the beginning, and 4 and 8 hours later. In 17 legs, the pressure sensor sites were marked, and their heights were measured on standing upright. SS and CS lost interface pressure quickly, but LS maintained pressure better than SS and CS at all sites. There was no pressure difference between SS and CS at the lower leg. However, CS maintained pressure better than SS at the mid thigh (44.6% vs. 54.4% pressure loss at 8 hours, respectively. P=0.037). There was a tendency toward less slippage with CS than SS at the mid thigh. In CS and LS, there was a linear correlation between the slippage of bandages and the interface pressure at the mid thigh (P <.01, in both). The interface pressure may be affected by the slippage of bandages at the thigh, but not at the lower leg. Cohesive short stretch bandages may exert their beneficial impact at the thigh.
In Vitro Effect of Lysozyme on Albumin Deposition to Hydrogel Contact Lens Materials.
Babaei Omali, Negar; Subbaraman, Lakshman N; Heynen, Miriam; Fadli, Zohra; Coles-Brennan, Chantal; Jones, Lyndon W
2017-11-01
Albumin deposition on contact lenses could be detrimental to contact lens (CL) wear because this may increase the risk of bacterial binding and reduce comfort. Lysozyme deposition on selected lens materials would reduce albumin deposition on lenses. This study aims to determine if lysozyme deposition on CLs could act as a barrier against subsequent albumin adsorption, using an in vitro model. Six hydrogel CL materials (etafilcon A, polymacon, nelfilcon A, omafilcon A, ocufilcon B, and nesofilcon A) were evaluated. Four CLs of each type were soaked in lysozyme solution for 16 hours at 37°C. Lysozyme-coated lenses were then placed in vials with 1.5 mL of artificial tear solution containing I-labeled albumin for 16 hours at 37°C with shaking. Four uncoated lenses of each type were used as controls. Lenses soaked in radiolabeled albumin were rinsed in a phosphate-buffered saline solution, and radioactive counts were measured directly on lenses using a gamma counter. Albumin uptake on lenses was measured using a calibration curve by plotting radioactive counts versus protein concentration. Results are reported as mean ± SD. Lysozyme-coated etafilcon A lenses exhibited lower levels of deposited albumin than uncoated etafilcon A lenses (58 ± 12 vs. 84 ± 5 ng/lens; P < .05). There were no differences in albumin adsorption between control (uncoated) and lysozyme-coated polymacon (105 ± 10 vs. 110 ± 34 ng/lens), nelfilcon A (51 ± 7 vs. 42 ± 20 ng/lens), omafilcon A (90 ± 20 vs. 80 ± 38 ng/lens), ocufilcon B (87 ± 20 vs. 115 ± 50 ng/lens), and nesofilcon A (170 ± 29 vs. 161 ± 10 ng/lens) lens materials (P > .05). Uncoated nesofilcon A lenses deposited the highest amount of albumin when compared with other uncoated lenses (P < .05). This study demonstrates that lysozyme deposited onto etafilcon A resists the deposition of albumin, which may potentially be beneficial to CL wearers.
Choo, Jennifer; Vuu, Kathy; Bergenske, Peter; Burnham, Kara; Smythe, Jennifer; Caroline, Patrick
2005-02-01
A number of reports have indicated an association between swimming with contact lenses and subsequent eye infection. This study tests whether a hydrophilic contact lens worn while swimming accumulates bacteria present in the water. It was of interest to determine whether lens type (silicone hydrogel vs. hydrogel) affected the result. Fifteen healthy noncontact lens wearers swam for 30 minutes with a silicone hydrogel lens (PureVision, Bausch & Lomb, Rochester, NY) on one eye and a hydrogel lens (Acuvue 2, Vistakon Inc., Jacksonville, FL) on the other. Lenses were removed aseptically and placed in sterile vials 10 minutes after the subjects left the water. Microbial growth was enumerated for total numbers of colonies and categorized by species present. Numbers of colonies were compared between the two lens groups and with a water sample taken from the pool at the time of the experiment. Eight of the subjects returned on a different day and wore new lenses for 50 minutes in normal room conditions. Two lenses were lost while swimming. Twenty-seven of the remaining 28 lenses worn while swimming showed colonization, principally with Staphylococcus epidermidis, which was also by far the most common species identified from the water itself. Small numbers of Staphylococcus aureus and Streptococcus salivarius were also present in the water and on the lenses. Numbers of colonies varied among subjects (range, 0 to 230), but no differences were observed between the two lens groups. Lenses removed after 30 minutes of wear without swimming were mostly sterile, with 3 of 16 lenses showing just two colonies each. It appears that wearing a hydrophilic lens while swimming allows accumulation of microbial organisms on or in the lens, regardless of lens material. Swimmers should be advised to wear tight-fitting goggles if lenses are worn while swimming, and thorough disinfection of the lenses before overnight wear seems prudent.
Influence of protein deposition on bacterial adhesion to contact lenses.
Subbaraman, Lakshman N; Borazjani, Roya; Zhu, Hua; Zhao, Zhenjun; Jones, Lyndon; Willcox, Mark D P
2011-08-01
The aim of the study is to determine the adhesion of Gram positive and Gram negative bacteria onto conventional hydrogel (CH) and silicone hydrogel (SH) contact lens materials with and without lysozyme, lactoferrin, and albumin coating. Four lens types (three SH-balafilcon A, lotrafilcon B, and senofilcon A; one CH-etafilcon A) were coated with lysozyme, lactoferrin, or albumin (uncoated lenses acted as controls) and then incubated in Staphylococcus aureus (Saur 31) or either of two strains of Pseudomonas aeruginosa (Paer 6294 and 6206) for 24 h at 37 °C. The total counts of the adhered bacteria were determined using the H-thymidine method and viable counts by counting the number of colony-forming units on agar media. All three strains adhered significantly lower to uncoated etafilcon A lenses compared with uncoated SH lenses (p < 0.05). Lysozyme coating on all four lens types increased binding (total and viable counts) of Saur 31 (p < 0.05). However, lysozyme coating did not influence P. aeruginosa adhesion (p > 0.05). Lactoferrin coating on lenses increased binding (total and viable counts) of Saur 31 (p < 0.05). Lactoferrin-coated lenses showed significantly higher total counts (p < 0.05) but significantly lower viable counts (p < 0.05) of adhered P. aeruginosa strains. There was a significant difference between the total and viable counts (p < 0.05) that were bound to lactoferrin-coated lenses. Albumin coating of lenses increased binding (total and viable counts) of all three strains (p < 0.05). Lysozyme deposited on contact lenses does not possess antibacterial activity against certain bacterial strains, whereas lactoferrin possess an antibacterial effect against strains of P. aeruginosa.
Water Exposure is a Common Risk Behavior Among Soft and Gas-Permeable Contact Lens Wearers
Richdale, Kathryn; Mitchell, Gladys Lynn; Kinoshita, Beth T.; Lam, Dawn Y.; Wagner, Heidi; Sorbara, Luigina; Chalmers, Robin L.; Collier, Sarah A.; Cope, Jennifer R.; Rao, Maya M.; Beach, Michael J.; Yoder, Jonathan S.
2017-01-01
Purpose: To understand soft contact lens (SCL) and gas-permeable (GP) lens wearers' behaviors and knowledge regarding exposure of lenses to water. Methods: The Contact Lens Risk Survey (CLRS) and health behavior questions were completed online by a convenience sample of 1056 SCL and 85 GP lens wearers aged 20 to 76 years. Participants were asked about exposing their lenses to water and their understanding of risks associated with these behaviors. Chi-square analyses examined relationships between patient behaviors and perceptions. Results: GP lens wearers were more likely than SCL wearers to ever rinse or store lenses in water (rinsing: 91% GP, 31% SCL, P < 0.001; storing: 33% GP, 15% SCL P < 0.001). Among SCL wearers, men were more likely to store (24% vs. 13%, P = 0.003) or rinse (41% vs. 29%, P = 0.012) their lenses in water. Showering while wearing lenses was more common in SCL wearers (86%) than GP lens wearers (67%) (P < 0.0001). Swimming while wearing lenses was reported by 62% of SCL wearers and 48% of GP lens wearers (P = 0.027). Wearers who rinsed (SCL; P < 0.0001, GP; P = 0.11) or stored lenses in water (SCL; P < 0.0001, GP P = 0.007) reported that this behavior had little or no effect on their infection risk, compared with those who did not. Both SCL (P < 0.0001) and GP lens wearers (P < 0.0001) perceived that distilled water was safer than tap water for storing or rinsing lenses. Conclusions: Despite previously published evidence of Acanthamoeba keratitis' association with water exposure, most SCL, and nearly all GP lens wearers, regularly expose their lenses to water, with many unaware of the risk. PMID:28410356
Effect of Daily Contact Lens Cleaning on Ocular Adverse Events during Extended Wear.
Ozkan, Jerome; Rathi, Varsha M; de la Jara, Percy Lazon; Naduvilath, Thomas; Holden, Brien A; Willcox, Mark D P
2015-02-01
The purpose of the study was to assess what effect daily cleaning of contact lenses with a multipurpose disinfection solution (MPDS), during 30 nights extended wear, would have on contact lens-related adverse events. This was a prospective, open-label, randomized, controlled, parallel-group, 3-month clinical study in which 193 participants were dispensed with lotrafilcon A silicone hydrogel lenses for a 30-day extended-wear schedule and with lenses replaced monthly. Participants were randomized to a control or test group. Test subjects were required to remove lenses daily after waking, clean them with the MPDS, and reinsert the lenses. Control subjects wore lenses without removal for 30 days extended wear. Handling-related lens contamination was assessed at the baseline visit. There was no significant difference between the test and control groups for the incidence of significant corneal infiltrative events (1.3 vs. 4.9%, p = 0.368), total corneal infiltrative events (2.6 vs. 4.9%, p = 0.682), or mechanical events (1.3 vs. 2.5%, p = 1.00). The test group had greater corneal staining (p < 0.047) and fewer mucin balls (p = 0.033). Handling-related lens contamination (unworn lenses) resulted in isolation of Gram-positive bacteria from 92.5% of test lenses compared with 87.5% of control lenses (p = 0.712). Gram-negative bacteria were isolated from 5% of test subjects compared with 2.5% of control subjects (p = 1.00). Fungus was isolated from 2.5% of subjects in both the test and control groups (p = 1.00). The intervention of daily morning cleaning of the lens surface with an MPDS during extended wear did not significantly influence the incidence of adverse events.
Water Exposure is a Common Risk Behavior Among Soft and Gas-Permeable Contact Lens Wearers.
Zimmerman, Aaron B; Richdale, Kathryn; Mitchell, Gladys Lynn; Kinoshita, Beth T; Lam, Dawn Y; Wagner, Heidi; Sorbara, Luigina; Chalmers, Robin L; Collier, Sarah A; Cope, Jennifer R; Rao, Maya M; Beach, Michael J; Yoder, Jonathan S
2017-08-01
To understand soft contact lens (SCL) and gas-permeable (GP) lens wearers' behaviors and knowledge regarding exposure of lenses to water. The Contact Lens Risk Survey (CLRS) and health behavior questions were completed online by a convenience sample of 1056 SCL and 85 GP lens wearers aged 20 to 76 years. Participants were asked about exposing their lenses to water and their understanding of risks associated with these behaviors. Chi-square analyses examined relationships between patient behaviors and perceptions. GP lens wearers were more likely than SCL wearers to ever rinse or store lenses in water (rinsing: 91% GP, 31% SCL, P < 0.001; storing: 33% GP, 15% SCL P < 0.001). Among SCL wearers, men were more likely to store (24% vs. 13%, P = 0.003) or rinse (41% vs. 29%, P = 0.012) their lenses in water. Showering while wearing lenses was more common in SCL wearers (86%) than GP lens wearers (67%) (P < 0.0001). Swimming while wearing lenses was reported by 62% of SCL wearers and 48% of GP lens wearers (P = 0.027). Wearers who rinsed (SCL; P < 0.0001, GP; P = 0.11) or stored lenses in water (SCL; P < 0.0001, GP P = 0.007) reported that this behavior had little or no effect on their infection risk, compared with those who did not. Both SCL (P < 0.0001) and GP lens wearers (P < 0.0001) perceived that distilled water was safer than tap water for storing or rinsing lenses. Despite previously published evidence of Acanthamoeba keratitis' association with water exposure, most SCL, and nearly all GP lens wearers, regularly expose their lenses to water, with many unaware of the risk.
Vijay, Ajay Kumar; Willcox, Mark D P
2017-09-26
Contact lens cases become contaminated with microbes during use. We wished to compare the adhesion of uncommon bacterial contaminants isolated from lens cases to contact lenses with and without organic soil. Strains of Delftia acidovorans (001), Stenotrophomonas maltophilia (002 and 006), and Achromobacter xylosoxidans (001) isolated from contact lens cases (test strains) and Pseudomonas aeruginosa (Paer1) isolated from eyes at the time of infiltrative response (control strain) were used. Bacteria were grown and resuspended in phosphate-buffered saline (PBS) or 10% organic soil (heat-killed Saccharomyces cerevisiae resuspended in complement inactivated bovine serum). Two silicone hydrogel (senofilcon A and comfilcon A) and one hydrogel lens (etafilcon A) lens materials were used. Bacteria (1.0×10 and 1.0×10 colony-forming units/mL; CFU/mL) adhered to lenses for 24 hr and the numbers of bacteria adherent to each lens type (with and without organic soil) were estimated by culture. All the four test strains adhered in significantly greater numbers to contact lenses after incubation in inoculum prepared with organic soil compared with PBS-D. acidovorans 001 (0.7 log10 CFU; P<0.05), S. maltophilia 002 (1.7 log10 CFU; P<0.05), S. maltophilia 006 (0.9 log10 CFU; P<0.05), and A. xylosoxidans 001 (0.4 log10 CFU; P<0.05). However, the presence of organic soil did not increase adhesion of P. aeruginosa Paer1 (-0.1 log10 CFU; P>0.05). Achromobacter xylosoxidans 001 (P<0.01), D. acidovorans 001 (P<0.01), and S. maltophilia 002 (P<0.01) significantly differed in their adhesion to the three contact lens materials. Bacteria that are commonly found in contact lens cases adhered to contact lenses in relatively high numbers in the presence of organic soil. This might indicate that a similar phenomenon occurs in the presence of tears. This may facilitate their transfer from the lens to the cornea and the production of corneal infiltrates.
Optical edge effects create conjunctival indentation thickness artefacts.
Sorbara, Luigina; Simpson, Trefford L; Maram, Jyotsna; Song, Eun Sun; Bizheva, Kostadinka; Hutchings, Natalie
2015-05-01
Conjunctival compression observed in ultrahigh resolution optical coherence tomography (UHR-OCT) images of contact lens edges could be actual tissue alteration, may be an optical artefact arising from the difference between the refractive indexes of the lens material and the conjunctival tissue, or could be a combination of the two. The purpose of this study is to image the artefact with contact lenses on a non-biological (non-indentable) medium and to determine the origins of the observed conjunctival compression. Two-dimensional cross-sectional images of the edges of a selection of marketed silicone hydrogel and hydrogel lenses (refractive index ranging from 1.40 to 1.43) were acquired with a research grade UHR-OCT system. The lenses were placed on three continuous surfaces, a glass sphere (refractive index n = 1.52), a rigid contact lens (n = 1.376) and the cornea of a healthy human subject (average n = 1.376). The displacement observed was analysed using ImageJ. The observed optical displacement ranged between 5.39(0.06) μm with Acuvue Advance and 11.99(0.18) μm with Air Optix Night & Day when the lens was imaged on the glass reference sphere. Similarly, on a rigid contact lens displacement ranged between 5.51(0.03) and 9.72(0.12) μm. Displacement was also observed when the lenses were imaged on the human conjunctiva and ranged from 6.49(0.80) μm for the 1-day Acuvue Moist to 17.4(0.22) μm for the Pure Vision contact lens. An optical displacement artefact was observed when imaging a contact lens on two rigid continuous surfaces with UHR-OCT where compression or indentation of the surface could not have been a factor. Contact lenses imaged in situ also exhibited displacement at the intersection of the contact lens edge and the conjunctiva, likely a manifestation of both the artefact and compression of the conjunctiva. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.
Thin film transistors for flexible electronics: contacts, dielectrics and semiconductors.
Quevedo-Lopez, M A; Wondmagegn, W T; Alshareef, H N; Ramirez-Bon, R; Gnade, B E
2011-06-01
The development of low temperature, thin film transistor processes that have enabled flexible displays also present opportunities for flexible electronics and flexible integrated systems. Of particular interest are possible applications in flexible sensor systems for unattended ground sensors, smart medical bandages, electronic ID tags for geo-location, conformal antennas, radiation detectors, etc. In this paper, we review the impact of gate dielectrics, contacts and semiconductor materials on thin film transistors for flexible electronics applications. We present our recent results to fully integrate hybrid complementary metal oxide semiconductors comprising inorganic and organic-based materials. In particular, we demonstrate novel gate dielectric stacks and semiconducting materials. The impact of source and drain contacts on device performance is also discussed.
Severinsky, Boris; Wajnsztajn, Denise; Frucht-Pery, Joseph
2013-11-01
The aim was to the evaluate performance of a novel silicone hydrogel mini-scleral contact lens (SHmS) for optical correction of keratoconus in the early stages after the corneal collagen cross-linking procedure (CXL). We retrospectively analysed the visual acuity improvement and corneal adaptation in the first 10 eyes of nine patients fitted with SHmS lenses one to 3.5 months after corneal collagen cross-linking. The lenses were designed to rest over the patients' sclera and peri-limbal cornea and vault the central cornea with minimal support over it. Visual acuities with manifest refraction and contact lenses, refractive and topographical values (Kmin and Kmax) were evaluated on lens dispensing and after six month of lens wearing. Ocular physiological responses were evaluated using the Institute of Eye Research (IER) grading scales. SHmS fitting was performed 2.1 ± 0.97 (SD) months after collagen cross-linking. Mean follow up was 10.9 ± 4.41 months (range six to 18 months). Mean decimal visual acuity with SHmS was 0.66 ± 0.22 (approximately 6/9 Snellen fraction, range 0.3 to 0.1) or 0.75 ± 0.14 (approximately 6/8.1, range 0.5 to 1.0), when omitting two amblyopic eyes. Nine (90 per cent) eyes were successfully fitted, that is, able to wear the lenses for 10 hours per day or longer. Mean wearing time was 11.7 hours (range six to 14) per day. No corneal neovascularisation or papillary reaction was found in all fitted eyes. SHmS contact lenses provide successful visual rehabilitation shortly after corneal collagen cross-linking. This new soft contact lens design with scleral fixation and minimal apical touch was demonstrated to be safe shortly after collagen cross-linking, as the avoidance of contact with the treated zone minimises contact lens influence on corneal recovery. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Knowledge, usage and barriers associated with contact lens wear in Ghana.
Abokyi, Samuel; Manuh, George; Otchere, Heinz; Ilechie, Alex
2017-10-01
Despite findings that contact lens wear for vision correction provides better quality of life than spectacles, contact lens use in developing countries is low. This study evaluated knowledge, usage and barriers associated with contact lens wear among spectacle wearers in Cape Coast, Ghana. A cross-sectional survey using a structured questionnaire was conducted on an adult population of spectacle wearers to assess their knowledge of contact lens wear for vision correction. The participants were proportionately sampled from three eye clinics in the Cape Coast Metropolis, Ghana. Questionnaires were either self-administered or completed with the help of a research assistant. Of the 422 participants, only 147 (34.8%) knew of contact lens wear for vision correction. The proportion of spectacle wearers reporting history of contact lens wear was 14 (3.3%). Barriers to contact lens wear reported were satisfaction with vision through spectacles 102 (25.0%), lack of adequate information 111 (27.2%), fear of side effects 94 (23.0%) and cost 78 (19.1%). The younger adults and those with higher number of changes of spectacles were more likely to know of contact lenses. Knowledge and usage of contact lenses among spectacle wearers was low. Contact lens education and demonstration of visual performance through fitting of trial contact lenses on potential candidates may help overcome barriers to contact lens wear. Published by Elsevier Ltd.
The Antibiofilm efficacy of nitric oxide on soft contact lenses.
Kim, Dong Ju; Park, Joo-Hee; Kim, Marth; Park, Choul Yong
2017-11-21
To investigate the antibiofilm efficacy of nitric oxide (NO) on soft contact lenses. Nitrite (NO precursor) release from various concentrations (0-1000 μM) of sodium nitrite (NaNO 2, NO donor) was measured by Griess Assay. Cell viability assay was performed using human corneal epithelial cell under various concentration (0-1000 μM) of NaNO 2 . Biofilm formation on soft contact lenses was achieved by adding Staphylococcus aureus or Pseudomonas aeruginosa to the culture media. Various concentrations of NaNO 2 (0-1000 μM) were added to the culture media, each containing soft contact lens. After incubation in NaNO 2 containing culture media for 1, 3, or 7 days, each contact lens was transferred to a fresh, bacteria-free media without NaNO 2 . The bacteria in the biofilm were dispersed in the culture media for planktonic growth. After reculturing the lenses in the fresh media for 24 h, optical density (OD) of media was measured at 600 nm and colony forming unit (CFU) was counted by spreading media on tryptic soy agar plate for additional 18 h. Nitrite release from NaNO 2 showed dose-dependent suppressive effect on biofilm formation. Most nitrite release from NaNO 2 tended to occur within 30 min. The viability of human corneal epithelial cells was well maintained at tested NaNO 2 concentrations. The bacterial CFU and OD showed dose-dependent decrease in the NaNO 2 treated samples on days 1, 3 and 7 for both Staphylococcus aureus and Pseudomonas aeruginosa. NO successfully inhibited the biofilm formation by Staphylococcus aureus or Pseudomonas aeruginosa on soft contact lenses in dose-dependent manner.
Bilgihan, Kamil; Yuksel, Erdem; Deniz, Nuriye Gokcen; Yuksel, Nilay
2015-01-01
Corneal collagen cross linking (CCL) with ultraviolet A (UVA) has been proposed as a treatment for the progression of corneal ectasia associated with keratoconus and post-laser-assisted in situ keratomileusis (LASIK) ectasia. Despite the reports about safety of procedure, we consider that UVA of sunlight can effect riboflavin saturated and de-epitelizated cornea early after CCL. To evaluate the UVA blockage capability of 11 different silicone hydrogel contact lenses which are widely used after CCL treatment. Eleven different silicone hydrogel and daily disposable contact lenses were evaluated. The UVA light at 365 nm wavelength for UVA source and UV light meter to measure UVA radiation were used. 3, 9 and 18 mW/cm(2) power of UV radiance was applied centrally to the each type of contact lenses. The power of UVA transmittance for each radiance and percentage of blockage were evaluated for each brand. Also, protection factor (PF) was calculated. The senofilcon A and narafilcon A had the highest blockage and lowest transmittance (p = 0.02). PF was significantly higher in the senofilcon A and narafilcon A at 3, 9 and 18 mW/cm(2) (p = 0.0001). And also, the hilafilcon B, filcon IV, nelfilcon A, enfilcon A, lotrafilcon A and lotrafilcon B had the highest UVA transmittance. The narafilcon A and the senofilcon A may be a good options for epithelial healing after CCL procedure to protect the cornea from UVA of sunlight. And also, the hilafilcon B, filcon IV, nelfilcon A, enfilcon A, lotrafilcon A and lotrafilcon B contact lenses that have high-UVA transmittance feature can be a treatment choice for contact lens-assisted CCL technique in thin corneas.
Anomalies in the prescribing of soft contact lens power.
Young, Graeme; Moody, Kurt; Sulley, Anna
2009-01-01
To determine the proportion of prescribed soft lenses rounded to the nearest half diopter and any variations from country to country and between lens types. Marketing data were obtained for soft lenses supplied during a 1-year period for lenses representing each of the following categories: mid-water hydrogel (MWH), silicone hydrogel, daily disposable, and toric silicone hydrogel (TSH). The data were analyzed for several countries/regions. Spherical lenses were analyzed in the range 1.00 to 5.75 D for plus and minus powers, and toric lenses in the range 0.50 to 5.75 D. This ensured a similar number of lenses in full or half diopter powers were compared with quarter and three-quarter diopter powers, and that there was no enforced rounding due to nonavailability of powers. By comparing the proportion of lenses from the 2 power groups, the proportion of lenses rounded to the nearest half diopter was estimated. It was assumed that half the difference between the totals of the 2 power groups represented those lenses dispensed to the nearest half diopter and, therefore, dispensed inaccurately; this was termed the "rounding rate" (RR). The power distribution curve for the sphere powers spiked in half diopter steps, illustrated a bias toward prescribing full and half diopter powers. With all lenses, the RR varied widely between countries. For the MWH, this ranged from 1.7% (Canada) to 11.6% (Iberia). The RRs were 2 to 3 times higher for plus than minus power lenses, however, this also varied by country. Overall, the RRs were lower for the silicone hydrogel and daily disposable contact lenses compared with the MWH, in particular for France and Iberia. The TSH results showed the greatest consistency between countries, with RRs ranging from 3.9% (Germany) to 9.5% (Rest of Europe). Most countries showed similar or lower RRs for TSH compared with MWH although, for some countries (e.g., United Kingdom, Nordic), these were higher. There was less difference in RRs for TSH lenses between plus and minus spheres. A surprising proportion of soft lenses are prescribed to the nearest half diopter, although this varies according to lens type. There are also considerable variations between countries, presumably due to differences in training, fitting practices, and supply routes. These findings suggest that there is widespread room for improvement in the prescribing accuracy of soft contact lenses.
Elseht, Rabab Mohamed; Nagy, Khaled Ahmed
2018-05-01
To evaluate the clinical value of rigid gas permeable contact lenses in children after traumatic corneal scarring. This comparative study included 15 children (age range: 5.7 to 14 years; mean ± standard deviation = 9.4 ± 2.9 years) with corneal scars and best corrected visual acuity (BCVA) of worse than 20/20, history of penetrating ocular trauma, and/or cataract extraction. All children were advised to wear spherical rigid gas permeable contact lenses for 6 months with a special regimen. Visual acuity was compared before and after fitting. The total and anterior surface aberrations of all children were measured using a corneal topographer before and after treatment. There was a significant improvement in the BCVA after wearing rigid gas permeable contact lenses compared to spectacle visual acuity (P = .001). There was also significant improvement of the keratometric astigmatism (P = .001) and corneal aberrations such as higher order aberrations (P = .008), lower order aberrations, root mean square, and point spread function (P = .001). The optical performance of rigid gas permeable contact lenses has been demonstrated to be effective in the visual rehabilitation of children with traumatic corneal lacerations. Corneal topography was an objective tool for detecting optical disorders. [J Pediatr Ophthalmol Strabismus. 2018;55(3):178-181.]. Copyright 2018, SLACK Incorporated.
Assessing tear film on soft contact lenses with lateral shearing interferometry.
Szczesna, Dorota H
2011-11-01
Evaluating precorneal tear film is one of important clinical measurements for assessing health of anterior eye. Contact lens wear is known to influence the quality of tear film. The aim was to evaluate the applicability of lateral shearing interferometry technique in the noninvasive assessment of the effects of contact lens replacement modality and its water content on tear film stability. Sixteen regular soft contact lens wearers took place in the study. Lateral shearing interferometry measurements, in suppressed blinking conditions, were taken in the mornings and afternoons, after a minimum of 5 hours of lens wear for the daily lenses, and after 2 weeks and 1 month for the fortnightly and monthly lens replacement modalities, respectively. Significant differences (paired bootstrap-based Behrens-Fisher test, P < 0.05) in the tear film surface quality were found between all considered pairs of replacement modalities except for the daily and fortnightly lenses measured in the afternoon of the first day of wear. Significant worsening (paired bootstrap-based Behrens-Fisher test, P < 0.001) of tear film quality was found for the low water content materials. Lateral shearing interferometry is a powerful method for the noninvasive assessment of tear film surface quality on soft contact lenses that may find, in future, its use in the clinical assessment of anterior eye's health.
Controlled Release of Multiple Therapeutics from Silicone Hydrogel Contact Lenses.
White, Charles James; DiPasquale, Stephen Anthony; Byrne, Mark Edward
2016-04-01
The majority of contact lens wearers experience a significant level of ocular discomfort associated with lens wear, often within hours of wear, related to dry lenses, inflammation, protein adhesion to the lens surface, etc. Application of controlled drug release techniques has focused on the incorporation and/or release of a single comfort molecule from a lens including high molecular weight comfort agents or pharmaceutical agents. Previous studies have sought to mitigate the occurrence of only single propagators of discomfort. Clinical studies with eye drop solutions have shown that a mixture of diverse comfort agents selected to address multiple propagators of discomfort provide the greatest and longest lasting sensations of comfort for the patient. In this paper, multiple propagators of discomfort are addressed through the simultaneous release of four molecules from a novel contact lens to ensure high level of lens wear comfort. Silicone hydrogel contact lenses were engineered via molecular imprinting strategies to simultaneously release up to four template molecules including hydropropyl methylcellulose (HPMC), trehalose, ibuprofen, and prednisolone. By adjusting the ratio of functional monomer to comfort molecule, a high level of control was demonstrated over the release rate. HPMC, trehalose, ibuprofen, and prednisolone were released at therapeutically relevant concentrations with varying rates from a single lens. The results indicate use as daily disposable lenses for single day release or extended-wear lenses with multiple day release. Imprinted lenses are expected to lead to higher efficacy for patients compared to topical eye drops by improving compliance and mitigating concentration peaks and valleys associated with multiple drops.
Controlled Release of Multiple Therapeutics from Silicone Hydrogel Contact Lenses
White, Charles J.; DiPasquale, Stephen A.; Byrne, Mark E.
2016-01-01
Purpose The majority of contact lens wearers experience a significant level of ocular discomfort associated with lens wear, often within hours of wear, related to dry lenses, inflammation, protein adhesion to the lens surface, etc. Application of controlled drug release techniques has focused on the incorporation and/or release of a single comfort molecule from a lens including high molecular weight comfort agents or pharmaceutical agents. Previous studies have sought to mitigate the occurrence of only single propagators of discomfort. Clinical studies with eye drop solutions have shown that a mixture of diverse comfort agents selected to address multiple propagators of discomfort provide the greatest and longest lasting sensations of comfort for the patient. In this paper, multiple propagators of discomfort are addressed through the simultaneous release of four molecules from a novel contact lens to ensure high level of lens wear comfort. Methods Silicone hydrogel contact lenses were engineered via molecular imprinting strategies to simultaneously release up to four template molecules including hydropropyl methylcellulose (HPMC), trehalose, ibuprofen, and prednisolone. Results By adjusting the ratio of functional monomer to comfort molecule, a high level of control was demonstrated over the release rate. HPMC, trehalose, ibuprofen, and prednisolone were released at therapeutically relevant concentrations with varying rates from a single lens. Conclusions The results indicate use as daily disposable lenses for single day release or extended-wear lenses with multiple day release. Imprinted lenses are expected to lead to higher efficacy for patients compared to topical eye drops by improving compliance and mitigating concentration peaks and valleys associated with multiple drops. PMID:26945177
The epidemiology of microbial keratitis with silicone hydrogel contact lenses.
Stapleton, Fiona; Keay, Lisa; Edwards, Katie; Holden, Brien
2013-01-01
It was widely anticipated that after the introduction of silicone hydrogel lenses, the risk of microbial keratitis would be lower than with hydrogel lenses because of the reduction in hypoxic effects on the corneal epithelium. Large-scale epidemiological studies have confirmed that the absolute and relative risk of microbial keratitis is unchanged with overnight use of silicone hydrogel materials. The key findings include the following: (1) The risk of infection with 30 nights of silicone hydrogel use is equivalent to 6 nights of hydrogel extended wear; (2) Occasional overnight lens use is associated with a greater risk than daily lens use; (3) The rate of vision loss due to corneal infection with silicone hydrogel contact lenses is similar to that seen in hydrogel lenses; (4) The spectrum of causative organisms is similar to that seen in hydrogel lenses, and the material type does not impact the corneal location of presumed microbial keratitis; and (5) Modifiable risk factors for infection include overnight lens use, the degree of exposure, failing to wash hands before lens handling, and storage case hygiene practice. The lack of change in the absolute risk of disease would suggest that exposure to large number of pathogenic organisms can overcome any advantages obtained from eliminating the hypoxic effects of contact lenses. Epidemiological studies remain important in the assessment of new materials and modalities. Consideration of an early adopter effect with studies involving new materials and modalities and further investigation of the impact of second-generation silicone hydrogel materials is warranted.
García-Millán, Eva; Koprivnik, Sandra; Otero-Espinar, Francisco Javier
2015-06-20
This paper proposes an approach to improve drug loading capacity and release properties of poly(2-hydroxyethyl methacrylate) (p(HEMA)) soft contact lenses based on the optimization of the hydrogel composition and microstructural modifications using water during the polymerization process. P(HEMA) based soft contact lenses were prepared by thermal or photopolymerization of 2-hydroxyethyl methacrylate (HEMA) solutions containing ethylene glycol di-methacrylate as crosslinker and different proportions of N-vinyl-2-pyrrolidone (NVP) or methacrylic acid (MA) as co-monomers. Transmittance, water uptake, swelling, microstructure, drug absorption isotherms and in vitro release were characterized using triamcinolone acetonide (TA) as model drug. Best drug loading ratios were obtained with lenses containing the highest amount (200 mM) of MA. Incorporation of 40% V/V of water during the polymerization increases the hydrogel porosity giving a better drug loading capacity. In vitro TA release kinetics shows that MA hydrogels released the drug significantly faster than NVP-hydrogels. Drug release was found to be diffusion controlled and kinetics was shown to be reproducible after consecutive drug loading/release processes. Results of p(HEMA) based soft contact lenses copolymerized with ethylene glycol dimethacrylate (EGDMA) and different co-monomers could be a good alternative to optimize the loading and ocular drug delivery of this corticosteroid drug. Copyright © 2015. Published by Elsevier B.V.
In-office microwave disinfection of soft contact lenses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, M.G.; Rechberger, J.; Grant, T.
1990-02-01
We evaluated the effectiveness of an in-office microwave disinfection procedure which allowed for the disinfection of up to 40 soft contact lenses at one time. Ciba AOSept cases filled with sterile unpreserved saline were contaminated with one of six FDA test challenge microorganisms at a concentration of approximately 10(3) colony forming units per milliliter (CFU/ml). Twenty cases were placed on the rotating plate of a standard 2450 MHz 650 W microwave oven in a 10-cm diameter circle. The cases were exposed to high intensity microwave irradiation for periods of 0 to 15 min. None of the 6 microorganisms evaluated survivedmore » 2 min or longer of microwave exposure. Our findings indicated that microwave irradiation can be a convenient, rapid, and effective method of disinfecting a number of soft contact lenses at one time and thus adaptable as an in-office soft contact lens disinfection procedure.« less
Kuc, Christopher J; Lebow, Kenneth A
2018-06-13
This article will examine the current literature, as it relates to contact lens discomfort (CLD) secondary to contact lens solutions. The reader will better understand the characteristics of contact lenses, as they uniquely interact with each type of contact lens solution and also gain a better comprehension of the components of contact lens solution such as preservatives, surfactants, and chelating agents, which may contribute to discomfort. By investigating corneal staining theory and the mechanisms that contribute to its presence, the reader will gain insight into this clinical finding, which relates to selection of contact lens solutions. The FDA standards for testing solutions and how this relates to contact lens keratitis will also be appraised in regards to current ISO recommendations. Finally, better selection of multipurpose contact lens solution (MPS) and hydrogen peroxide-based solutions for patients should be accessible to the clinician based on this review and preexisting clinical findings or diagnoses. A review of current published literature from peer reviewed journals and online journals was conducted to gain an understanding of contact lens solution's impact on contact lens discomfort. Many studies have been conducted comparing comfort between various types of contact lens solutions. It is challenging to decipher this information and apply it clinically when selecting solutions for patients. By comparing solution components, how contact lens solutions interact with different types of lenses, keratitis related to contact lenses, and preexisting ocular conditions, this review will improve a clinician's ability to eliminate CLD.
NASA Astrophysics Data System (ADS)
Sokoloff, J. B.
2014-09-01
One role of a lubricant is to prevent wear of two surfaces in contact, which is likely to be the result of adhesive forces that cause a pair of asperities belonging to two surfaces in contact to stick together. Such adhesive sticking of asperities can occur both for sliding surfaces and for surfaces which are pressed together and then pulled apart. The latter situation, for example, is important for contact lenses, as prevention of sticking reduces possible damage to the cornea as the lenses are inserted and removed from the eye. Contact lenses are made from both neutral and polyelectrolyte hydrogels. It is demonstrated here that sticking of neutral hydrogels can be prevented by repulsive forces between asperities in contact, resulting from polymers attached to the gel surface but not linked with each other. For polyelectrolyte hydrogels, it is shown that osmotic pressure due to counterions, held at the interface between asperities in contact by the electrostatic attraction between the ions and the fixed charges in the gel, can provide a sufficiently strong repulsive force to prevent adhesive sticking of small-length-scale asperities.
Contamination risk of reusing daily disposable contact lenses.
Boost, Maureen; Poon, Kin-Chiu; Cho, Pauline
2011-12-01
This study investigated contamination of saline and daily disposable contact lens (DDCL) stored overnight after use in the original blister pack and the practices of a group of DDCL users. Twenty DDCL wearers placed their lenses after 1 day's use back into the blister pack saline (BPS) and left them overnight before transferring both lens and BPS to a new CL case. The lens and BPS were cultured the following day, and total number of organisms, Staphylococci, and gram negative organisms enumerated. Each subject submitted five pairs of lenses over a 1 month period. Ninety-five percent of subjects had at least one pair of contaminated lenses, and the BPS yielded similar results to the contaminated lenses, with staphylococcal contamination being predominant. Three subjects admitted to not washing their hands before handling their lenses and six to habitual reuse of their lenses with storage in the BPS. There was a higher risk of contamination in male subjects. Reuse of lenses poses an important risk for DDCL users because they are unlikely to have received proper training in cleaning and disinfection of lenses and do not use a lens case or disinfecting solutions. Overnight storage in BPS results in contaminated lenses which if reused increases the infection risk especially with Staphylococci. It is important that practitioners carefully educate their patients in correct use of DDCL and, as cost of lenses is a major factor in willingness to reuse, ensure that DDCL is the most suitable choice when prescribing.
Visual performance with sport-tinted contact lenses in natural sunlight.
Erickson, Graham B; Horn, Fraser C; Barney, Tyler; Pexton, Brett; Baird, Richard Y
2009-05-01
The use of tinted and clear contact lenses (CLs) in all aspects of life is becoming a more popular occurrence, particularly in athletic activities. This study broadens previous research regarding performance-tinted CLs and their effects on measures of visual performance. Thirty-three subjects (14 male, 19 female) were fitted with clear B&L Optima 38, 50% visible light transmission Amber and 36% visible light transmission Gray-Green Nike Maxsight CLs in an individualized randomized sequence. Subjects were dark-adapted with welding goggles before testing and in between subtests involving a Bailey-Lovie chart and the Haynes Distance Rock test. The sequence of testing was repeated for each lens modality. The Amber and Gray-Green lenses enabled subjects to recover vision faster in bright sunlight compared with clear lenses. Also, subjects were able to achieve better visual recognition in bright sunlight when compared with clear lenses. Additionally, the lenses allowed the subjects to alternate fixation between a bright and shaded target at a more rapid rate in bright sunlight as compared with clear lenses. Subjects preferred both the Amber and Gray-Green lenses over clear lenses in the bright and shadowed target conditions. The results of the current study show that Maxsight Amber and Gray-Green lenses provide better contrast discrimination in bright sunlight, better contrast discrimination when alternating between bright and shaded target conditions, better speed of visual recovery in bright sunlight, and better overall visual performance in bright and shaded target conditions compared with clear lenses.
1992-10-01
Astigmatism 1 I Accommodation and Convergence 12 Advantages and Disadvantages of Contact Lenses 12 Optical Performance 12 Compliance 13 Supervision 13...absence of parallel tear lens, especially advantages of dealing with only one type of lens and accompanying astigmatism ) support system. - discomfort...Polcon I low. provides an explanation for the failure of high Dk Potycon 1I 8 a materials in fitting a cornea with astigmatism and the Si-02-•• ex need
Code of Federal Regulations, 2013 CFR
2013-01-01
... maintained contents in the specified quantities: Contents Quantity Adhesive bandage compresses, 1-inch 16 Antiseptic swabs 20 Ammonia inhalants 10 Bandage compresses, 4-inch 8 Triangular bandage compresses, 40-inch 5 Arm splint, noninflatable 1 Leg splint, noninflatable 1 Roller bandage, 4-inch 4 Adhesive tape, 1...
21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...
Code of Federal Regulations, 2014 CFR
2014-01-01
... maintained contents in the specified quantities: Contents Quantity Adhesive bandage compresses, 1-inch 16 Antiseptic swabs 20 Ammonia inhalants 10 Bandage compresses, 4-inch 8 Triangular bandage compresses, 40-inch 5 Arm splint, noninflatable 1 Leg splint, noninflatable 1 Roller bandage, 4-inch 4 Adhesive tape, 1...
Code of Federal Regulations, 2012 CFR
2012-01-01
... maintained contents in the specified quantities: Contents Quantity Adhesive bandage compresses, 1-inch 16 Antiseptic swabs 20 Ammonia inhalants 10 Bandage compresses, 4-inch 8 Triangular bandage compresses, 40-inch 5 Arm splint, noninflatable 1 Leg splint, noninflatable 1 Roller bandage, 4-inch 4 Adhesive tape, 1...
21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...
Code of Federal Regulations, 2011 CFR
2011-01-01
... maintained contents in the specified quantities: Contents Quantity Adhesive bandage compresses, 1-inch 16 Antiseptic swabs 20 Ammonia inhalants 10 Bandage compresses, 4-inch 8 Triangular bandage compresses, 40-inch 5 Arm splint, noninflatable 1 Leg splint, noninflatable 1 Roller bandage, 4-inch 4 Adhesive tape, 1...
21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...
21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...
21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...
Sankaridurg, P R; Sharma, S; Willcox, M; Sweeney, D F; Naduvilath, T J; Holden, B A; Rao, G N
1999-05-01
To report the association between colonization of contact lenses with Streptococcus pneumoniae and the observation of corneal infiltrative events in a group of patients wearing disposable hydrogel lenses on an extended-wear schedule. In a prospective clinical trial, 330 patients wore disposable hydrogels on a 6-night extended-wear and replacement schedule. The contact lens, lid, and conjunctival microbiota of these subjects was analyzed at frequent intervals and at the time of an adverse event. Streptococcus pneumoniae was an uncommon isolate and was recovered from only one of the 3,763 conjunctival samples, five (0.1%) of the 3,764 lid samples, and 33 (0.8%) of the 4,315 contact lens samples. Of the 33 lens samples, 10 (30%) were associated with corneal infiltrative events. Many of the events were mild inflammatory responses and resolved rapidly on discontinuation of lens wear. The presence of S. pneumoniae on the contact lens was associated with a significant risk of development of corneal infiltrates (odds ratio, 3.0; p = 0.0227, logistic-regression analysis). Presence of S. pneumoniae on hydrogel lenses is a significant risk factor for the development of corneal infiltrates.
The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry.
Zeri, Fabrizio; De Cusatis, Mario; Lupelli, Luigi; Swann, Peter Graham
2016-01-01
To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects' right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses. Copyright © 2016 The Authors. Published by Elsevier Espana.. All rights reserved.
Measuring sub-bandage pressure: comparing the use of pressure monitors and pulse oximeters.
Satpathy, A; Hayes, S; Dodds, S R
2006-03-01
To test the use of low-cost sub-bandage pressure monitors and pulse oximeters as part of a quality-control measure for graduated compression bandaging in leg ulcer clinics. Twenty-five healthy volunteers (mean age 40 years) providing 50 limbs were bandaged with a four-layer compression bandaging system. The ankle systolic pressure (ASP) was measured using a pulse oximeter (Nellcor NBP-40) before applying the graduated compression bandages. Interface pressure was measured by placing pressure sensors on the skin at three points (2cm above the medial malleolus; the widest part of the calf; and a point midway between them) in the supine and standing positions. The ASP was measured again with the pulse oximeter after the bandage had been applied, and the effect of the bandage on the ASP was recorded. The actual pressure created by the bandage was compared with the required pressure profile. Interface pressures varied with change of position and movement. With the operator blinded to the pressure monitors while applying the bandages, the target pressure of 35-40mmHg at the ankle was achieved in only 36% of limbs ([mean +/- 95% confidence interval]; 32.3 +/- 1.6mmHg [supine]; 38.4 +/- 2.4mmHg [standing position]). With the help of the pressure monitors, the target pressure was achieved in 78% of the limbs. There was no correlation between the pressure monitors and pulse oximeter pressures, demonstrating that the pulse oximeter is not a useful tool for measuring sub-bandage pressures. The results suggest a tool (interface pressure monitors) that is easy to operate should be available as part of quality assurance for treatment, training of care providers and education.
Acanthamoeba keratitis in Scotland: risk factors for contact lens wearers.
Seal, D V; Kirkness, C M; Bennett, H G; Peterson, M
1999-01-01
To investigate risk factors for Acanthamoeba keratitis amongst contact lens wearers in Scotland. Patients with Acanthamoeba keratitis in the Scottish study, all of whom wore contact lenses, were compared with 46 healthy asymptomatic contact lens-wearing controls. They were all visited at home for contact lens and environmental microbiological sampling. In addition, all 288 optical practices in the West of Scotland were polled for contact lens types and disinfecting solutions sold in 1995, and a sample, each of whom fitted more than 500 contact lenses per year, were polled for a second time. Independently, a poll was commissioned by the Eyecare Information Service in July/August 1995 to estimate the numbers of contact lens wearers in Scotland and the UK. Industry was polled for numbers of each contact lens disinfecting regimen sold in Scotland in 1995. West of Scotland, UK. All contact lens wearers among the 3 million population of the West of Scotland Health Board Areas. Risk factors for Acanthamoeba infection and recommendations for its prevention. When Acanthamoeba infection occurred, patients' home water systems were frequently (54%) found to be colonised by this amoeba. Patients more frequently washed their storage cases in tap water than controls (P<0.05) with resulting contamination, kept storage cases wet rather than air drying them (P<0.05), and had coliform bacteria cultured from the storage case (P<0.05) and had viable Acanthamoeba within the storage case (P<0.0001). Overall, patients were found to have significantly more risk factors than controls (P<0.0001). The noncompliant use of chlorine tablet disinfection, or failure to disinfect contact lenses at all, was associated with increased risk (P<0.05). Ionic high water content contact lenses (FDA group 4 material), when used without disinfection or with non-compliant use of low chlorine (Soflab) tablet-based disinfection, were associated with increased risk of Acanthamoeba infection (P<0.05). In log-linear modelling of risky hygiene behaviours associated with contamination of storage cases with Acanthamoeba, the most significant behaviour was found to be use of the less effective disinfection methods (chlorine tablets or no disinfection). However further investigation showed that these methods were associated with an increased probability of rinsing the storage case in tap water, so that these two behaviours are confounded in the group studied. Failure to disinfect contact lenses, non-compliant use of chlorine tablets and/or introduction of tap water rinsing of storage cases were associated with increased risk of Acanthamoeba infection. New multipurpose solutions and hydrogen peroxide gave the lowest risk of Acanthamoeba infection, with no statistically significant difference between them. Ionic high-water content (FDA group 4) contact lenses were at increased risk of being associated with Acanthamoeba keratitis if used without effective disinfection (multipurpose solutions or hydrogen peroxide). The use of domestic tap water for contact lens and storage case hygiene must be avoided, as a chain-of-causation' was identified from the home water supply.
Biocompatibility in the development of silicone-hydrogel lenses.
Jacob, Jean T
2013-01-01
In response to patient demands for extended contact lens wearing times, the contact lens industry has developed novel silicone-hydrogel (SiHy) lens materials that combine the enhanced oxygen permeability of silicone polymers with the water-based comfort of conventional hydrogels. In the past 12 years since the successful launch of these SiHy lenses, much has been learned about their ability to provide the biocompatibility necessary to sustain ocular health and comfort. A review of the unique physiologic requirements for a successful extended wear lens and how the first and current SiHy lenses address them is provided.
Delivery of compression therapy for venous leg ulcers.
Zarchi, Kian; Jemec, Gregor B E
2014-07-01
Despite the documented effect of compression therapy in clinical studies and its widespread prescription, treatment of venous leg ulcers is often prolonged and recurrence rates high. Data on provided compression therapy are limited. To assess whether home care nurses achieve adequate subbandage pressure when treating patients with venous leg ulcers and the factors that predict the ability to achieve optimal pressure. We performed a cross-sectional study from March 1, 2011, through March 31, 2012, in home care centers in 2 Danish municipalities. Sixty-eight home care nurses who managed wounds in their everyday practice were included. Participant-masked measurements of subbandage pressure achieved with an elastic, long-stretch, single-component bandage; an inelastic, short-stretch, single-component bandage; and a multilayer, 2-component bandage, as well as, association between achievement of optimal pressure and years in the profession, attendance at wound care educational programs, previous work experience, and confidence in bandaging ability. A substantial variation in the exerted pressure was found: subbandage pressures ranged from 11 mm Hg exerted by an inelastic bandage to 80 mm Hg exerted by a 2-component bandage. The optimal subbandage pressure range, defined as 30 to 50 mm Hg, was achieved by 39 of 62 nurses (63%) applying the 2-component bandage, 28 of 68 nurses (41%) applying the elastic bandage, and 27 of 68 nurses (40%) applying the inelastic bandage. More than half the nurses applying the inelastic (38 [56%]) and elastic (36 [53%]) bandages obtained pressures less than 30 mm Hg. At best, only 17 of 62 nurses (27%) using the 2-component bandage achieved subbandage pressure within the range they aimed for. In this study, none of the investigated factors was associated with the ability to apply a bandage with optimal pressure. This study demonstrates the difficulty of achieving the desired subbandage pressure and indicates that a substantial proportion of patients with venous leg ulcers do not receive adequate compression therapy. Training programs that focus on practical bandaging skills should be implemented to improve management of venous leg ulcers.
Robert Mandell: a pioneer and giant in the art and science of contact lenses.
Polse, Kenneth A
2008-10-01
Robert B. Mandell is the quintessential modern clinical scientist. Over his long academic career, he has pioneered many advances in contact lens practice, ranging from a more complete understanding of corneal shape to the effects of contact lenses on corneal health. His classic text, Contact Lens Practice, first published in 1965, was reprinted 14 times in four editions up to 1988. Mandell's contributions to the advancement of the profession of optometry have always been characterized by a genuine concern for the patient and a steadfast belief that his research must have relevance to the practice of optometry.
Ciolino, Joseph B.; Hoare, Todd R.; Iwata, Naomi G.; Behlau, Irmgard; Dohlman, Claes H.; Langer, Robert; Kohane, Daniel S.
2014-01-01
Purpose To formulate and characterize a drug-eluting contact lens designed to provide extended, controlled release of a drug. Methods Prototype contact lenses were created by coating PLGA (poly[lactic-co-glycolic acid]) films containing test compounds with pHEMA (poly[hydroxyethyl methacrylate]) by ultraviolet light polymerization. The films, containing encapsulated fluorescein or ciprofloxacin, were characterized by scanning electron microscopy. Release studies were conducted in phosphate-buffered saline at 37°C with continuous shaking. Ciprofloxacin eluted from the contact lens was studied in an antimicrobial assay to verify antimicrobial effectiveness. Results After a brief and minimal initial burst, the prototype contact lenses demonstrated controlled release of the molecules studied, with zero-order release kinetics under infinite sink conditions for over 4 weeks. The rate of drug release was controlled by changing either the ratio of drug to PLGA or the molecular mass of the PLGA used. Both the PLGA and the pHEMA affected release kinetics. Ciprofloxacin released from the contact lenses inhibited ciprofloxacin-sensitive Staphylococcus aureus at all time-points tested. Conclusions A prototype contact lens for sustained drug release consisting of a thin drug-PLGA film coated with pHEMA could be used as a platform for ocular drug delivery with widespread therapeutic applications. PMID:19136709
Vision of low astigmats through thick and thin lathe-cut soft contact lenses.
Cho, P; Woo, G C
2001-01-01
Distance and near visual acuity of 13 low astigmats were determined in a double-masked experiment through thick and thin (centre thickness 0.12 mm and 0.06 mm, respectively) spherical lathe-cut soft lenses. For each lens type, distance and near LogMAR VA and over-refraction were assessed with different logMAR VA charts. For 70% of the subjects, the residual astigmatism was significantly lower than the refractive astigmatism with thicker lenses. No statistically significant differences in the distance and near logMAR VA was found between the two lens types using any of the charts used, though, in general, logMAR VA obtained through the thicker lens was better than logMAR VA through the thinner lens. The variabilities in distance and near logMAR VA between the two lens types increased with decreased contrast. The variabilities in distance logMAR VA were greater with Chinese charts than with English charts, and LogMAR VA with Chinese charts were significantly worse for both lens types. Based on the results of this study, we concluded that thicker spherical lathe-cut soft lenses provide better vision in low astigmats. The Snellen acuity test is inadequate for vision assessment of soft contact lens wearers. When a patient wearing thin soft contact lenses complains of poor vision in spite of 6/6 or 6/5 Snellen acuity, changing to thicker lenses may be considered.
Effects of wearing a daily disposable lens on tear film: a randomised controlled trial.
Chong, Pamela Qin Yi; Yeo, Sharon; Too, Cheah Loon; Boo, Cynthia; Tong, Louis
2016-05-01
Contact lens-induced dry eye is commonly encountered, although its extent is not well documented with daily disposable lenses. A novel type of contact lens system incorporating moisturising agent (alginic acid) has been developed. The aim of this study was to evaluate the effect of wearing daily 2-hydroxyethyl methacrylate disposable contact lenses for seven days on tear stability, conjunctival and limbal redness and dry eye symptoms. Then, we aimed to determine whether lens solutions containing alginic acid had any influence on tear parameters. This was a seven-day parallel group double-masked clinical trial of previous contact lens wearers, where participants were randomly assigned to wearing SEED 1dayPure moisture contact lenses with (n = 15) or without alginic acid (n = 15). Tear lipid layer thickness (LLT), non-invasive tear break-up time (NIBUT), conjunctival redness, corneal fluorescein staining, tear break-up time and Schirmer I readings were measured. Symptom severity and frequency were evaluated and combined using a global score from visual analogue scales. The mean age and standard deviation of the participants was 25 ± 3.8 years. There were 24 females and six males. After reintroduction of contact lens wear for one week, there was significant improvement in the global symptom score; however, this may not be clinically significant. There were small and clinically insignificant changes in limbal and conjunctival hyperaemia but no significant changes in lipid layer thickness, Schirmer I and NIBUT in overall participants. The use of alginic acid in lens solutions did not affect these parameters compared to control lenses (p > 0.05). After seven days of wearing a modern daily disposable lens, there was no significant deterioration of tear function in a group of young contact lens wearers. In this short-term study, there was no evidence of significant benefit of lens solutions containing alginic acid used with HEMA lenses. © 2016 The Authors Clinical and Experimental Optometry © 2016 Optometry Australia.
Santos, Lívia; Rodrigues, Diana; Lira, Madalena; Oliveira, M Elisabete C D Real; Oliveira, Rosário; Vilar, Eva Yebra-Pimentel; Azeredo, Joana
2007-07-01
To evaluate the influence of surface treatment of silicone-hydrogel CL on lens hydrophobicity, protein adsorption and microbial colonisation by studying several silicone hydrogel contact lenses (CL) with and without surface treatment. The lenses used in this study were Balafilcon A, Lotrafilcon A, Lotrafilcon B and Galyfilcon A. A conventional hydrogel CL (Etafilcon A) was also tested. Hydrophobicity was determined through contact angle measurement using the advancing type technique on air. The type and quantity of proteins adsorbed were assessed through SDS-PAGE and fluorescence spectroscopy, respectively. Microbial colonisation was studied by removing the microbes from the lenses through sonication, and counting the colony-forming units on agar plates. Regarding hydrophobicity, both surface and non-surface-treated silicone hydrogel CL were found to be hydrophobic, and the conventional hydrogel CL was found to be hydrophilic. Concerning protein adsorption, different protein profiles were observed on the several lenses tested. Nevertheless, the presence of proteins with the same molecular weight as lysozyme and lactoferrin was common to all lenses, which is probably related to their abundance in tears. In terms of total protein adsorption, silicone hydrogel CL did not exhibit any differences between themselves. However, the conventional hydrogel Etafilcon A adsorbed a larger amount of proteins. Regarding microbial colonisation, Balafilcon A exhibited the greatest amount of colonising microbes, which can be due to its superior hydrophobicity and higher electron acceptor capacity. This study suggests that silicone hydrogel lenses adsorb a lower amount of proteins than the conventional hydrogel lenses and that this phenomenon is independent of the presence of surface treatment. Concerning microbial colonisation, the surface treated Balafilcon A, exhibited a greater propensity, a fact that may compromise the lens wearer's ocular health.
... your prescription expires Lens measurements The contact lens brand name and material Your doctor’s name and contact ... mail-order sellers may send you a different brand. Contact lenses may look the same, but materials ...
Zimmerman, Aaron B; Marks, Amanda
2014-01-01
To report a case of neurotrophic keratitis in which scleral contact lenses improved vision from 20/100 to 20/20, however, due to poor lens care, an incident of microbial keratitis developed. A 64-year-old man with an ocular history of neurotrophic keratitis secondary to herpes simplex in each eye was successfully fit with scleral lenses. He subsequently developed microbial keratitis due to a number of risk factors. The lesion was culture negative, yet was very responsive to treatment with moxifloxacin. The lesion fully healed, and the patient did not suffer additional vision loss. This case demonstrates the ability of scleral lenses to correct visual impairments secondary to poor epithelial integrity and illustrates the importance of the practitioner providing detailed lens care instruction.
Veli, Muhammed; Ozcan, Aydogan
2018-03-27
We present a cost-effective and portable platform based on contact lenses for noninvasively detecting Staphylococcus aureus, which is part of the human ocular microbiome and resides on the cornea and conjunctiva. Using S. aureus-specific antibodies and a surface chemistry protocol that is compatible with human tears, contact lenses are designed to specifically capture S. aureus. After the bacteria capture on the lens and right before its imaging, the captured bacteria are tagged with surface-functionalized polystyrene microparticles. These microbeads provide sufficient signal-to-noise ratio for the quantification of the captured bacteria on the contact lens, without any fluorescent labels, by 3D imaging of the curved surface of each lens using only one hologram taken with a lens-free on-chip microscope. After the 3D surface of the contact lens is computationally reconstructed using rotational field transformations and holographic digital focusing, a machine learning algorithm is employed to automatically count the number of beads on the lens surface, revealing the count of the captured bacteria. To demonstrate its proof-of-concept, we created a field-portable and cost-effective holographic microscope, which weighs 77 g, controlled by a laptop. Using daily contact lenses that are spiked with bacteria, we demonstrated that this computational sensing platform provides a detection limit of ∼16 bacteria/μL. This contact-lens-based wearable sensor can be broadly applicable to detect various bacteria, viruses, and analytes in tears using a cost-effective and portable computational imager that might be used even at home by consumers.
Microbial contamination of soft contact lenses & accessories in asymptomatic contact lens users.
Thakur, Deeksha V; Gaikwad, Ujjwala N
2014-08-01
With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Four samples each from 50 participants (n=200) were collected from the lenses, lens care solutions, lens care solution bottles and lens cases along with a questionnaire regarding their lens use. The samples were inoculated onto sheep blood agar, Mac Conkey's agar and Sabouraud's dextrose agar. Organisms were identified using standard laboratory protocols. Overall rate of microbial contamination among the total samples was 52 per cent. The most and the least contaminated samples were found to be lens cases (62%) and lens care solution (42%), respectively. The most frequently isolated contaminant was Staphylococcus aureus (21%) followed by Pseudomonas species (19.5%). Majority (64%) of the participants showed medium grade of compliance to lens cleaning practices. Rate of contamination was 100 and 93.75 per cent respectively in those participants who showed low and medium compliance to lens care practices as compared to those who had high level of compliance (43.75%) (P<0.05). Lens care practices amongst the participants were not optimum which resulted into high level contamination. Hence, creating awareness among the users about the lens care practices and regular cleaning and replacements of lens cases are required.
Cosmetic Cleansing Oil Absorption by Soft Contact Lenses in Dry and Wet Conditions.
Tsukiyama, Junko; Miyamoto, Yuko; Kodama, Aya; Fukuda, Masahiko; Shimomura, Yoshikazu
2017-09-01
Previous reports showed that cosmetic cleansing oil for removing makeup, which contains mineral oil and surfactant, can deform some silicone hydrogel contact lenses (SHCLs) when applied directly to the lenses, although plasma-coated SHCLs (lotrafilcon A and B) were not affected. In the present study, we investigated hydrogel lenses and SHCLs in both wet and dry conditions. Several brands of hydrogel and SHCLs were immersed in a cleansing oil solution containing Sudan Black B for 5 min under wet and dry conditions. The lenses under the wet condition were simply picked up from the saline, whereas those under the dry condition were blotted with paper wipes. After immersing, the excess solution remaining on the lenses was removed by finger rubbing with a multipurpose solution. The lenses were then examined using a stereomicroscope, and their mean brightness was measured and compared. The cosmetic cleansing oil was not absorbed by the hydrogel lenses under wet or dry conditions. However, four of seven brands of SHCLs absorbed the cosmetic cleansing oil under both conditions (dry and wet), whereas asmofilcon A absorbed it only under the dry condition. Lotrafilcon B and delefilcon A did not absorb cleansing oil even under the dry condition. Hydrogel lenses resist cosmetic cleansing oil. However, SHCLs have different degrees of resistance depending on the lens material. Some SHCLs absorbed cosmetic cleansing oil more under dry conditions than under wet conditions.
Riley, Colleen; Young, Graeme; Chalmers, Robin
2006-12-01
Many soft contact lens wearers have symptoms or signs that compromise successful lens wear. This study estimated the prevalence of problems in current wearers of soft contact lenses and tested the effect of refitting patients with senofilcon A silicone hydrogel lenses (ACUVUE Oasys). Prevalence was estimated from 1,092 current lens wearers for frequent or constant discomfort or dryness, at least 2 hours of uncomfortable wear, at least grade 2 limbal or bulbar hyperemia (0-4), or at least grade 3 corneal staining (0-15). In the second part of the study, 112 of the 564 wearers classified as problem patients were refitted with senofilcon A lenses and reassessed 2 weeks later. Fifty-two percent (564 of 1,092) had some qualifying criteria, with dryness reported by 23%, discomfort by 13%, and at least 2 hours of uncomfortable wear by 27%. Six percent of subjects had qualifying limbal hyperemia; 10% had bulbar hyperemia; and 12% had corneal staining. After refitting 112 problem patients, 75% had less dryness; 88% had better comfort (P<0.0001 each); and 76% had fewer uncomfortable hours of wear (P=0.004). Although the average wearing time was unchanged, comfortable wearing time increased significantly (10.4 to 11.6 hours) (P=0.004). All (35 of 35) eyes with qualifying limbal hyperemia before the refit also improved (P<0.0001), as did 80% (40 of 50) of those with bulbar hyperemia (P<0.0001) and 76% (26 of 34) of those with corneal staining (P=0.005). Most soft lens wearers encounter clinically significant signs or symptoms with their current contact lenses. Refitting with new-generation silicone hydrogel lenses (senofilcon A) can alleviate some of these common problems.
In vitro release of two anti-muscarinic drugs from soft contact lenses
Hui, Alex; Bajgrowicz-Cieslak, Magdalena; Phan, Chau-Minh; Jones, Lyndon
2017-01-01
The purpose of this study was to investigate the release of the anti-myopia drugs atropine sulfate and pirenzepine dihydrochloride from commercially available soft contact lenses. Standard ultraviolet (UV) absorbance–concentration curves were generated for atropine and pirenzepine. Ten commercially available contact lenses, including four multifocal lenses, were loaded by soaking in atropine or pirenzepine solutions at two different concentrations (10 mg/mL and 1 mg/mL). The release of the drugs into phosphate-buffered saline was determined over the course of 24 hours at 34°C using UV absorbance. Materials with surface charge released the greatest amount of atropine when loaded with either concentration when compared to the other lens types (p<0.05), releasing upward of 1.026±0.035 mg/lens and 0.979±0.024 mg/lens from etafilcon A and ocufilcon A, respectively. There were no significant differences in the amount of atropine or pirenzepine released from the multifocal and non-multifocal lenses made from the same lens materials. Narafilcon A material demonstrated prolonged release of up to 8 hours when loaded with pirenzepine, although the overall dose delivered from the lens into the solution was among the lowest of the materials investigated. The rest of the lenses reached a plateau within 2 hours of release, suggesting that they were unable to sustain drug release into the solution for long periods of time. Given that no single method of myopia control has yet shown itself to be completely effective in preventing myopia progression, a combination of optical and pharmaceutical devices comprising a drug delivering contact lens presents a novel solution that warrants further investigation. PMID:29213204
Myers, R I; Larsen, D W; Tsao, M; Castellano, C; Becherer, L D; Fontana, F; Ghormley, N R; Meier, G
1991-10-01
The purposes of this study were to determine if the quantity of protein deposited (QPD) upon hydrogel lenses was affected by enzymatic cleaning and to test the potential relation between QPD and visible protein deposition (VPD) and change. Seventy-four contact lens patients classified as "heavy depositors" wore new lenses for an average of 80 (SD = 32) days. Cleaning and disinfection solutions varied. One lens was cleaned weekly by a papain enzymatic treatment. The distribution of QPD measurements was bimodal and was related to the FDA material for nonionic, low water content lenses (FDA Materials Group no. 1). The mean deposition was 45 micrograms/cm2 (N = 112) compared with that of ionic, high water content lenses (FDA Materials Group no. 4), which was 1010 micrograms/cm2 (N = 30). VPD distributions were the same for the FDA Group no. 1 and no. 4 lenses. Enzymatic treatment did not significantly reduce QPD; however, enzymatic treatment did reduce VPD. Thus QPD and VPD are independent phenomena and possible reasons for this are given.
Oxygen permeability of the pigmented material used in cosmetic daily disposable contact lenses.
Galas, Stephen; Copper, Lenora L
2016-01-01
To evaluate the individual contributions of pigment colorant and packing solution containing polyvinyl pyrrolidone (PVP) on the oxygen permeability (Dk) of a cosmetic printed etafilcon A daily disposable contact lens packaged with PVP. The oxygen transport of a contact lens is evaluated through the central optical zone of the lens. Cosmetic printed contact lenses contain pigment colorant in the periphery or mid-periphery of the lens. Therefore, to assess the impact of cosmetic print on oxygen permeability, special lenses need to be produced that contain the colorant within the central optical zone. This technique was used to obtain multiple measurements of nonedge-corrected Dk/t of both the center pigmented lens and its nonpigmented equivalent, using a polarographic measurement described in International Organization for Standardization (ISO) 18369-4:2006(E), and the Dk derived for each measurement is corrected for edge effect. In addition, the edge-corrected Dk values of lenses made from the same monomer batch were measured. The lenses were packaged and autoclaved with and without proprietary technology which embeds PVP in the contact lens during autoclaving. The resulting Dk value of the printed lens material was then used with thickness data to generate true Dk/t profiles for a given lens power. The edge-corrected Dk of the printed etafilcon A lens with offset pigment colorant was measured to be 19.7×10 -11 (cm 2 /s) (mL O 2 /mL·mmHg) at 35°C. This was within ±20% tolerance range as specified in ISO 18369-2:2012(E) for the edge-corrected Dk of the nonpigmented etafilcon A control lens evaluated during the same session, 19.5×10 -11 (cm 2 /s) (mL O 2 /mL·mmHg). The edge-corrected Dk values of the lenses packaged with PVP (mean 20.1, standard deviation [SD] 0.3) were also within the ±20% tolerance range compared to those packaged without PVP (mean 20.0, SD 0.3). The pigment colorant and PVP embedded in the contact lens during autoclaving were not found to influence the oxygen permeability of the etafilcon A material.
Accommodation and Phoria in Children Wearing Multifocal Contact Lenses
Gong, Celia R; Troilo, David; Richdale, Kathryn
2017-01-01
Purpose To determine the effect of multifocal contact lenses on accommodation and phoria in children. Methods This was a prospective, non-dispensing, randomized, crossover, single visit study. Myopic children with normal accommodation and binocularity and no history of myopia control treatment were enrolled and fitted with Coopervision Biofinity single vision (SV) and multifocal (MF, +2.50D center distance add) contact lenses. Accommodative responses (photorefraction) and phorias (Modified Thorington) were measured at 4 distances (>3m, 100cm, 40cm, 25cm). Secondary measures included high and low contrast logMAR acuity, accommodative amplitude and facility. Differences between contact lens designs were analyzed using repeated measures regression and paired t-tests. Results A total of 16 subjects, aged 10-15 years, completed the study. There was a small decrease in high (SV: -0.08, MF: +0.01) and low illumination (SV:-0.03, MF: +0.08) (both p<0.01) visual acuity, and contrast sensitivity (SV: 2.0, MF: 1.9 log units, p=0.015) with multifocals. Subjects were more exophoric at 40 cm (SV: -0.41, MF: -2.06 Δ) and 25cm (SV: -0.83, MF: -4.30 Δ) (both p<0.01). With multifocals, subjects had decreased accommodative responses at distance (SV: -0.04; MF: -0.37 D, p=0.02), 100 cm (SV: +0.37; MF: -0.35 D, p<0.01), 40 cm (SV: +1.82; MF: +0.62 D, p<0.01), and 25 cm (SV: +3.38; MF: +1.75 D, p<0.01). There were no significant differences in accommodative amplitude (p=0.66) or facility (p=0.54). Conclusions Children wearing multifocal contact lenses exhibited reduced accommodative responses and more exophoria at increasingly higher accommodative demands than with single vision contact lenses. This suggests that children may be relaxing their accommodation and using the positive addition or increased depth of focus from added spherical aberration of the multifocals. Further studies are needed to evaluate other lens designs, different amounts of positive addition and aberrations, and long-term adaptation to lenses. PMID:28027276
NASA Astrophysics Data System (ADS)
Situmorang, B. H.; Setiawan, M. P.; Tosida, E. T.
2017-01-01
Refractive errors are abnormalities of the refraction of light so that the shadows do not focus precisely on the retina resulting in blurred vision [1]. Refractive errors causing the patient should wear glasses or contact lenses in order eyesight returned to normal. The use of glasses or contact lenses in a person will be different from others, it is influenced by patient age, the amount of tear production, vision prescription, and astigmatic. Because the eye is one organ of the human body is very important to see, then the accuracy in determining glasses or contact lenses which will be used is required. This research aims to develop a decision support system that can produce output on the right contact lenses for refractive errors patients with a value of 100% accuracy. Iterative Dichotomize Three (ID3) classification methods will generate gain and entropy values of attributes that include code sample data, age of the patient, astigmatic, the ratio of tear production, vision prescription, and classes that will affect the outcome of the decision tree. The eye specialist test result for the training data obtained the accuracy rate of 96.7% and an error rate of 3.3%, the result test using confusion matrix obtained the accuracy rate of 96.1% and an error rate of 3.1%; for the data testing obtained accuracy rate of 100% and an error rate of 0.
Ortillés, Ángel; Goñi, Pilar; Rubio, Encarnación; Sierra, Marta; Gámez, Ekaterina; Fernández, María T; Benito, María; Cristóbal, José Á; Calvo, Begoña
2017-02-01
To develop a rabbit model of Acanthamoeba keratitis (AK) as the best method to reproduce the natural course of this disease. To induce AK, infected contact lenses (1000 amoebae/mm2, 90% trophozoites) were placed over the previously debrided corneal surface, in combination with a temporary tarsorrhaphy. Environmental and clinical strains of Acanthamoeba spp. (genotype T4) were used. Three groups (1L, n = 32; 2L-21d, n = 5; 2L-3d, n = 23) were established according to the number of contact lenses used (1L, 1 lens; 2L-21d and 2L-3d, 2 lenses) and the placement day of these (1L, day 1; 2L-21d, days 1 and 21; 2L-3d, days 1 and 3). The infection was quantified by a clinical score system and confirmed using corneal cytology and culture, polymerase chain reaction and histopathologic analysis. The infection rate obtained was high (1L, 87.5%; 2L-21d, 100%; 2L-3d, 82.6%), although no clinical signs were observed in the 50% of the infected animals in group 1L. Among groups, group 2L-3d showed more cases of moderate and severe infection. Among strains, no statistically significant differences were found in the infection rate. In the control eyes, cross infection was confirmed when a sterile contact lens was placed in the previously debrided corneas but not if the eye remained intact. The combination of two infected contact lenses after corneal debridement seems to be an alternative model, clinically and histopathologically similar to its human counterpart, to induce the different AK stages and reproduce the course of the disease in rabbits.
Risk factors for contact lens bacterial contamination during continuous wear.
Szczotka-Flynn, Loretta B; Bajaksouzian, Saralee; Jacobs, Michael R; Rimm, Alfred
2009-11-01
Microbial contamination of contact lenses is associated with corneal infection and inflammation. This study determined the microbiological, clinical, and demographic factors that are associated with bacterial contamination of a silicone hydrogel contact lens when worn for continuous wear (CW). Two hundred five healthy subjects were enrolled in the Longitudinal Analysis of Silicone Hydrogel Contact Lens Study and were fitted with lotrafilcon A lenses for monthly CW and followed for 1 year. Lenses were aseptically removed after 1 week and 4 months of wear and cultured using an agar sandwich technique. Lids and conjunctiva were routinely cultured at baseline and after 1 week and 4 months of CW. Lenses and ocular sites were considered to have substantial microbial bioburden when they harbored pathogenic organisms or high levels of commensal organisms. Univariate and multivariate logistic regression analyses were conducted to examine whether substantial conjunctival or lid bioburden, subject demographics, lens-wearing history, symptoms, and biomicroscopic signs were associated with lens bioburden. About one third (32.4%) of subjects had substantial bacterial bioburden in either eye across multiple visits. Over half (53.2%) and about one tenth (11.7%) of subjects had substantial lid and conjunctival bioburden, respectively, and 11.2% discontinued because of discomfort. The adjusted odds ratios (and 95% confidence intervals) for presence of substantial lens bioburden were 2.49 (1.17-5.30), 4.24 (1.45-12.40), and 4.11 (1.17-14.46) for substantial lid bioburden, substantial conjunctival bioburden, and lens discomfort, respectively. Bacterial contamination of silicone hydrogel contact lenses is common during CW. Substantial lens bioburden is associated with discomfort precluding successful CW. The presence of substantial lid and conjunctival bioburden is associated with a 2.5-fold and more than fourfold greater risk of substantial lens bioburden and is likely the major route of contamination.
Corneal oedema in a unilateral corneal graft patient induced by high Dk mini-scleral contact lens.
Guillon, Natalie C; Godfrey, Andrew; Hammond, David S
2018-05-24
Scleral contact lenses are increasingly becoming accepted as the method of choice for visual correction of the irregular cornea. As such, cases have surfaced which demonstrate complications arising from mini-scleral lenses. Identification of these issues and adjusting fitting techniques accordingly is necessary for reducing the risks associated with mini-scleral lens wear. A 58 year old Caucasian female was referred for rigid gas permeable contact lens fitting for correction of right irregular astigmatism post penetrating keratoplasty. After four months of successful mini-scleral contact lens wear, the patient experienced a graft rejection episode and treated accordingly, then refit with a new mini-scleral lens. Five months after the lens refit, the patient presented with complaints of hazy vision, and a diagnosis of lens-induced corneal oedema made. Increased awareness of the potential complications of mini-scleral lenses is necessary to encourage and enforce mini-scleral lens fitting techniques that meet the requirements of minimum vault but adequate protection of the compromised cornea. Copyright © 2018 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Kwok, L Stephen; Kuznetsov, Valerian A; Ho, Arthur; Coroneo, Minas T
2003-04-01
Peripheral light-focusing (PLF) is an occult form of ultraviolet radiation (UVR) hazardous to the human eye. In PLF, obliquely incident light is refracted from the peripheral cornea to concentrated sites inside the anterior segment. In the current study, the directionality of this phenomenon for UVR and whether PLF is established in outdoor settings exposed to sunlight were investigated. The protection provided by a UV-blocking contact lens was also evaluated. UVA and UVB sensors were placed on the nasal limbus of an anatomically based model eye. The temporal limbus was exposed to a UV light source placed at various angles behind the frontal plane. PLF was quantified with the sensor output. The ensemble was mounted in the orbit of a mannequin head and exposed to sunlight in three insolation environments within the region of Sydney, Australia. PLF for UVA and UVB was determined with no eyewear or with sunglasses and commercially available soft contact lenses, with and without UV-blocking capability. The intensity of UVA peaked at approximately 120 degrees incidence, the level at which the UVB response was also at its maximum. The intensification of UVA was up to x18.3. The intensity of PLF for UVA and UVB was reduced by an order of magnitude by a UV-blocking contact lens, whereas a clear contact lenses had a much lesser effect. Only the UV-blocking contact lens achieved a significant effect on UVA and UVB irradiance in the urban, beach, and mountain locales (P < 0.056). The results identify another type of sunlight hazard: the peripheral focusing of obliquely incident light. UVR from albedo (reflected ambient light) is capable of establishing PLF in the anterior segment, but this can be shielded by UV-blocking soft contact lenses. Sunglasses may be unable to shield oblique rays, unless side protection is incorporated. Contact lenses can offer UVR protection against all angles of incidence, including the peak-response angle. They can also protect the eye in settings in which the wearing of sunglasses is not feasible or convenient.
Ajayi, B O; Kio, F E; Otajevwo, F D
2012-01-01
Fifty conjunctival swab samples collected from ELISA confirmed HIV/AIDS seropositive patients who were referred to the HIV/AIDS laboratories of the University of Benin Teaching Hospital and Central Hospital both based in Benin City, Nigeria were aseptically cultured on appropriate media by standard methods. The resulting isolates/strains, after identification by standard methods, were tested for their ability to adhere to two hydrophobic non-ionic daily wear silicone hydrogel soft contact lenses (i.e. lotrafilcon B, WC 33% and polymacon, WC 38%) as well as to two hydrophilic ionic conventional extended wear silicone hydrogel soft contact lenses (i.e. methafilcon A, WC 55% and omafilcon A, WC 60%) by the adhesiveness/slime production modified vortex/Robin device method. Evidence of adhesiveness/slime production was indicated by presence of a visible stained film lining the surface of the contact lens which was measured and recorded as strong or weak according to the density of the adhered bacterial film. Fourteen (28.0%) Staphylococcus aureus strains and 10 (20.0%) Pseudomonas aeruginosa strains were obtained among other organisms. Staphylococcus aureus strains adhered in decreasing order to lotrafilcon B (55.4 ± 4.7), polymacon (46.4 ± 8.4), methfilcon A (46.4 ± 8.4) and omafilcon A (25.0 ± 6.4) with no significant difference in adhesive strengths of individual strains (P > 0.05). Pseudomonas aeruginosa strains also recorded decreasing adhesive strengths to lotrafilcon B (37.5 ± 8.2), polymacon (28.6 ± 6.3), methafilcon A (26.8 ± 5.5) and omafilcon A (23.2 ± 5.5) also with no significant difference in adhesive strengths of individual strains (P > 0.05). Attachment strengths of Staph. aureus strains to all four contact lenses were higher than those of Pseudomonas aeruginosa strains. Both organisms adhered most to hydrophobic lotrafilcon B and least to hydrophilic omafilcon A. This invitro adhesion studies revealed that daily wear silicone hydrogel low water content, non-ionic contact lenses are more prone to bacterial adhesion than the conventional extended wear hydrogel high water content, ionic contact lenses and hence, there is more risk of microbial adhesion to the former compared to the latter. Other implications are highlighted.
B. O., Ajayi; F.E., Kio; F.D., Otajevwo
2012-01-01
Fifty conjunctival swab samples collected from ELISA confirmed HIV/AIDS seropositive patients who were referred to the HIV/AIDS laboratories of the University of Benin Teaching Hospital and Central Hospital both based in Benin City, Nigeria were aseptically cultured on appropriate media by standard methods. The resulting isolates/strains, after identification by standard methods, were tested for their ability to adhere to two hydrophobic non-ionic daily wear silicone hydrogel soft contact lenses (i.e. lotrafilcon B, WC 33% and polymacon, WC 38%) as well as to two hydrophilic ionic conventional extended wear silicone hydrogel soft contact lenses (i.e. methafilcon A, WC 55% and omafilcon A, WC 60%) by the adhesiveness/slime production modified vortex/Robin device method. Evidence of adhesiveness/slime production was indicated by presence of a visible stained film lining the surface of the contact lens which was measured and recorded as strong or weak according to the density of the adhered bacterial film. Fourteen (28.0%) Staphylococcus aureus strains and 10 (20.0%) Pseudomonas aeruginosa strains were obtained among other organisms. Staphylococcus aureus strains adhered in decreasing order to lotrafilcon B (55.4 ± 4.7), polymacon (46.4 ± 8.4), methfilcon A (46.4 ± 8.4) and omafilcon A (25.0 ± 6.4) with no significant difference in adhesive strengths of individual strains (P > 0.05). Pseudomonas aeruginosa strains also recorded decreasing adhesive strengths to lotrafilcon B (37.5 ± 8.2), polymacon (28.6 ± 6.3), methafilcon A (26.8 ± 5.5) and omafilcon A (23.2 ± 5.5) also with no significant difference in adhesive strengths of individual strains (P > 0.05). Attachment strengths of Staph. aureus strains to all four contact lenses were higher than those of Pseudomonas aeruginosa strains. Both organisms adhered most to hydrophobic lotrafilcon B and least to hydrophilic omafilcon A. This invitro adhesion studies revealed that daily wear silicone hydrogel low water content, non-ionic contact lenses are more prone to bacterial adhesion than the conventional extended wear hydrogel high water content, ionic contact lenses and hence, there is more risk of microbial adhesion to the former compared to the latter. Other implications are highlighted. PMID:22980120
Noninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses.
Ascaso, Francisco J; Huerva, Valentín
2016-04-01
: The incidence of diabetes mellitus is dramatically increasing in the developed countries. Tight control of blood glucose concentration is crucial to diabetic patients to prevent microvascular complications. Self-monitoring of blood glucose is widely used for controlling blood glucose levels and usually performed by an invasive test using a portable glucometer. Many technologies have been developed over the past decades with the purpose of obtaining a continuous physiological glycemic monitoring. A contact lens is the ideal vehicle for continuous tear glucose monitoring of glucose concentration in tear film. There are several research groups that are working in the development of contact lenses with embedded biosensors for continuously and noninvasively monitoring tear glucose levels. Although numerous aspects must be improved, contact lens technology is one step closer to helping diabetic subjects better manage their condition, and these contact lenses will be able to measure the level of glucose in the wearer's tears and communicate the information to a mobile phone or computer. This article reviews studies on ocular glucose and its monitoring methods as well as the attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors.
Optical Assessment of Soft Contact Lens Edge-Thickness.
Tankam, Patrice; Won, Jungeun; Canavesi, Cristina; Cox, Ian; Rolland, Jannick P
2016-08-01
To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2-μm imaging resolution in three dimensions and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses. A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester, NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error. The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. Fifty cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 μm. The results confirmed the ability of GD-OCM to provide high-definition images of soft contact lens edges. As a nondestructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCM in the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance.
Optical Assessment of Soft Contact Lens Edge-Thickness
Tankam, Patrice; Won, Jungeun; Canavesi, Cristina; Cox, Ian; Rolland, Jannick P.
2016-01-01
Purpose To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2 μm imaging resolution in three dimensions, and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses. Methods A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error. Results The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. 50 cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 μm. Conclusions The results confirmed the ability of GD-OCM to provide high definition images of soft contact lens edges. As a non-destructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCM in the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in-vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance. PMID:27232902
Scholtz, Sibylle K; Auffarth, Gerd U
2012-01-01
Alhazen, ibn al-Haytham, (965 Basra - c. 1040 in Cairo) was a Muslim polymath who made significant contributions to the principles of optics, being the first to recognize the optical effect by transparent objects in the 11th century. His insights led to a fundamental revolution, enabling older presbyopic persons to read again. Today many more options are available to help visually impaired people correct their sight defects. This article will give an historical overview of the sight aids which are available today and will describe the very first beginnings of the development of the "reading stone" or "glasses". Further, it will also give a chronological overview of more modern techniques, e.g., intraocular lenses, contact lenses and the options of refractive surgery.
Park, Young Min; Kwon, Han Jo; Lee, Jong Soo
2015-03-01
To determine the bacteriological spectrum of the removed therapeutic soft contact lenses (TSCLs) and to establish efficacy of prophylactic antibiotics on TSCLs used for 2 weeks for treatment of patients with recurrent corneal erosion syndrome (RCES). This study included idiopathic RCES treated using highly oxygen-permeable silicone hydrogel contact lenses (CLs), and treated 4 times per day with topical tobramycin 3% for 2 weeks. After TSCLs were applied for 2 weeks, the lenses were removed with sterile forceps under which a speculum was inserted, and placed on blood agar with the inner face down. The TSCLs were analyzed for bacterial colonization, and antibiotic susceptibility tests were performed for the isolates, using disk diffusion. Of the 40 lenses analyzed, 9 (22.5%) yielded positive cultures. Staphylococcus epidermidis was the most commonly isolated microorganism; there were five methicillin-sensitive coagulase-negative staphylococci and two methicillin-resistant coagulase-negative staphylococci. Furthermore, we found two lenses that were colonized by Enterobacter gergoviae and Citrobacter freundii. All cultured bacteria showed intermediate or complete sensitivity to ciprofloxacin, tigecycline, and tobramycin. Despite bacterial colonization in 9 CLs, no clinical signs of infectious keratitis were found in any of the patients with prophylactic topical tobramycin 3%. In case of using TSCLs for 2 weeks, tobramycin or ciprofloxacin may be useful as prophylactic topical antibiotics for preventing secondary corneal infections. Considering currently growing incidence of ciprofloxacin-resistant ocular isolates, tobramycin seems to be a reasonable prophylactic topical antibiotic susceptible broad spectrum of bacteria in clinics.
Power Profiles of Commercial Multifocal Soft Contact Lenses.
Kim, Eon; Bakaraju, Ravi C; Ehrmann, Klaus
2017-02-01
To evaluate the optical power profiles of commercially available soft multifocal contact lenses and compare their optical designs. The power profiles of 38 types of multifocal contact lenses-three lenses each-were measured in powers +6D, +3D, +1D, -1D, -3D, and -6D using NIMO TR1504 (Lambda-X, Belgium). All lenses were measured in phosphate buffered saline across 8 mm optic zone diameter. Refractive index of each lens material was measured using CLR 12-70 (Index Instruments, UK), which was used for converting measured power in the medium to in-air radial power profiles. Three basic types of power profiles were identified: center-near, center-distance, and concentric-zone ring-type designs. For most of the lens types, the relative plus with respect to prescription power was lower than the corresponding spectacle add. For some lens types, the measured power profiles were shifted by up to 1D across the power range relative to their labeled power. Most of the lenses were designed with noticeable amounts of spherical aberration. The sign and magnitude of spherical aberration can either be power dependent or consistent across the power range. Power profiles can vary widely between the different lens types; however, certain similarities were also observed between some of the center-near designs. For the more recently released lens types, there seems to be a trend emerging to reduce the relative plus with respect to prescription power, include negative spherical aberration, and keep the power profiles consistent across the power range.
An Investigation and Analysis of the Vestibulo-Ocular Reflex (VOR) in a Vibration Environment
2013-03-01
could not have had breast implants. Participants with corrective vision through LASIK , PRK or soft contacts were qualified but individuals requiring...corrective lenses (glasses/contact lenses)? YES/NO Have you had corrective eye surgery ( PRK / LASIK )? YES/NO Have you been diagnosed or...Figure 6. Relative Intensity vs . Forward Current for Everlight 5mm Infrared LED ........ 30 Figure 7. IR LED Circuit
Paradiso, Patrizia; Chu, Virginia; Santos, Luís; Serro, Ana Paula; Colaço, Rogério; Saramago, Benilde
2015-07-01
Although the plasma technology has long been applied to treat contact lenses, the effect of this treatment on the performance of drug-loaded contact lenses is still unclear. The objective of this work is to study the effect of nitrogen plasma treatment on two drug-loaded polymeric formulations which previously demonstrated to be suitable for therapeutic contact lenses: a poly-hydroxyethylmethacrylate (pHEMA) based hydrogel loaded with levofloxacin and a silicone-based hydrogel loaded with chlorhexidine. Modifications of the surface and the optical properties, and alterations in the drug release profiles and possible losses of the antimicrobial activities of the drugs induced by the plasma treatment were assessed. The results showed that, depending on the system and on the processing conditions, the plasma treatment may be beneficial for increasing wettability and refractive index, without degrading the lens surface. From the point of view of drug delivery, plasma irradiation at moderate power (200 W) decreased the initial release rate and the amount of released drug, maintaining the drug activity. For lower (100 W) and higher powers (300 W), almost no effect was detected because the treatment was, respectively, too soft and too aggressive for the lens materials. © 2014 Wiley Periodicals, Inc.
Glucose-sensitive silicone hydrogel contact lens toward tear glucose monitoring.
Badugu, Ramachandram; Reece, Edward Albert; Lakowicz, Joseph R
2018-05-01
Accurate and reliable monitoring of blood glucose is needed for the treatment of diabetes, which has many challenges, including lack of patient compliance. Measuring tear glucose is an alternative to traditional finger-stick tests used to track blood sugar levels, but glucose sensing using tears has yet to be achieved. We report a methodology for possible tear glucose monitoring using glucose-sensitive silicone hydrogel (SiHG) contact lenses, the primary type of lenses available in today's market. Initially, we assessed the interpenetrating polymer network, with nearly pure silicone and water regions, existing in the SiHGs using a polarity-sensitive probe Prodan. We then synthesized a glucose-sensitive fluorophore Quin-C18 with a hydrophobic side chain for localization of probe at the interfacial region. Using our glucose-sensing contact lens, we were able to measure varying concentrations of glucose in an in-vitro system. The Quin-C18 strongly bound to the lenses with insignificant leaching even after multiple rinses. The lenses displayed a similar response to glucose after three months of storage in water. This study demonstrates that it may be possible to develop a contact lens for continuous glucose monitoring in the near term, using our concept of fluorophore binding at the silicone-water interface. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
A Randomized Trial of Soft Multifocal Contact Lenses for Myopia Control: Baseline Data and Methods.
Walline, Jeffrey J; Gaume Giannoni, Amber; Sinnott, Loraine T; Chandler, Moriah A; Huang, Juan; Mutti, Donald O; Jones-Jordan, Lisa A; Berntsen, David A
2017-09-01
The Bifocal Lenses In Nearsighted Kids (BLINK) study is the first soft multifocal contact lens myopia control study to compare add powers and measure peripheral refractive error in the vertical meridian, so it will provide important information about the potential mechanism of myopia control. The BLINK study is a National Eye Institute-sponsored, double-masked, randomized clinical trial to investigate the effects of soft multifocal contact lenses on myopia progression. This article describes the subjects' baseline characteristics and study methods. Subjects were 7 to 11 years old, had -0.75 to -5.00 spherical component and less than 1.00 diopter (D) astigmatism, and had 20/25 or better logMAR distance visual acuity with manifest refraction in each eye and with +2.50-D add soft bifocal contact lenses on both eyes. Children were randomly assigned to wear Biofinity single-vision, Biofinity Multifocal "D" with a +1.50-D add power, or Biofinity Multifocal "D" with a +2.50-D add power contact lenses. We examined 443 subjects at the baseline visits, and 294 (66.4%) subjects were enrolled. Of the enrolled subjects, 177 (60.2%) were female, and 200 (68%) were white. The mean (± SD) age was 10.3 ± 1.2 years, and 117 (39.8%) of the eligible subjects were younger than 10 years. The mean spherical equivalent refractive error, measured by cycloplegic autorefraction was -2.39 ± 1.00 D. The best-corrected binocular logMAR visual acuity with glasses was +0.01 ± 0.06 (20/21) at distance and -0.03 ± 0.08 (20/18) at near. The BLINK study subjects are similar to patients who would routinely be eligible for myopia control in practice, so the results will provide clinical information about soft bifocal contact lens myopia control as well as information about the mechanism of the treatment effect, if one occurs.
Guillon, Michel; Maissa, Cécile; Wong, Stéphanie; Patel, Trisha; Garofalo, Renée
2018-04-14
To compare the effects of a hydrogen peroxide (H 2 O 2 )-based lens care solution and a polyhexamethylene biguanide (PHMB) multi-purpose solution on the eyelids when used with silicone hydrogel (SiHy) contact lenses. A total of 74 symptomatic wearers of ACUVUE ® OASYS ® (senofilcon A; n = 39) or PureVision ® (balafilcon A; n = 35) contact lenses were randomised 1:1 to either CLEAR CARE ® Cleaning & Disinfecting Solution or renu ® fresh™ multi-purpose solution (n = 37 each). Assessments of hyperaemia, papillae and lid margin staining of eyelid tissue were evaluated subjectively by a masked investigator at enrolment (with the subjects' habitual SiHy contact lenses and PHMB-preserved care systems), at dispensing visit (when no lenses were worn) and at 3-months' follow-up. There were no differences in eyelid assessments between the two lens care groups at dispensing visit (p = 0.086 to 0.947). After 3 months, the papillae response was significantly less marked with H2O2-based solution than with PHMB-based solution (p = 0.017). Lid hyperaemia (p < 0.001) and papillae (p = 0.002) were also significantly reduced. Although lid hyperaemia was also reduced with PHMB-based solution (p < 0.001), there was no concurrent decrease in papillae response (p = 0.051). No improvements were found in eyelid margin staining either over time or between the two lens care groups. In symptomatic contact lens wearers, a H 2 O 2 -based lens care solution used with senofilcon A and balafilcon A lenses was better tolerated by eyelid tissues than was a PHMB-based solution and led to a decrease in clinical markers of eyelid inflammation. Copyright © 2018 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Pearson, Richard M; Evans, Bruce J W
2012-11-01
To compare the repeatability and validity of measurements of the back vertex power (BVP) of spherical soft contact lenses made in-air using the method specified in the International Standard (ISO 18369-3:2006) with the corresponding values when BVP was calculated from measurements made using a wet cell and focimeter method that is not approved by this Standard. The BVP of 20 hydrogel and 20 silicone hydrogel lenses, with labelled powers ranging from +8.00 to -12.00 D, were measured with a focimeter by two operators on two occasions in-air in accordance with the relevant International Standard. Equivalent sets of measurements were made with the lenses immersed in-saline within a wet cell and their BVPs in-air were calculated. The validity of each method was assessed by comparing their results with an instrument that used the Hartmann method. The reliability results were generally a little better for the in-saline measurements than for the in-air measurements, although all reliability data demonstrated absolute values of mean errors (inter-operator and inter-session) that were <0.05 D for hydrogel lenses and <0.07 D for silicone hydrogel lenses. The in-air 95% confidence intervals were <0.45 D and <0.40 D for hydrogel and silicone hydrogel lenses, respectively and in-saline <0.39 and <0.31 D for hydrogel and silicone hydrogel lenses, respectively. The validity data revealed a relationship between measurement error and BVP for the in-air data (the focimeter overestimates the power of high plus and high minus lenses compared with the Hartmann instrument) and possibly a more complex relationship for the in-saline data. The 95% limits of agreement indicate better agreement for the in-saline validity data (-0.55 to +0.48 D for hydrogel lenses and -0.42 to +0.54 D for silicone hydrogel lenses) than those obtained in-air (-0.64 to +0.68 D for hydrogel lenses and -0.57 to +0.44 D for silicone hydrogel lenses). Using equipment readily available in a clinical setting, the wet cell method of measurement of the BVP of spherical soft contact lenses has been shown to provide results for reliability and validity that were at least as good as those obtained with the in-air method approved by the International Standard. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Susilowati, Endang, E-mail: endwati@yahoo.co.id; Ashadi; Maryani
Bandage is a medical device that is essential for wound dressing. To improve the performance of the bandage, it has been coated by silver-chitosan nanocomposites (Ag/Chit) with pad-dry-cure method. The nanocomposites were performed by chemical reduction method at room temperature using glucose as reducing agent, sodium hydroxide (NaOH) as accelerator reagent, silver nitrate (AgNO{sub 3}) as metal precursor and chitosan as stabilizing agent. Localized surface plasmon resonance (LSPR) absorption band of silver nanoparticles was investigated using UV-Vis spectrophotometer. The bandage coated Ag/Chit nanocomposites (B-Ag/Chit) were characterized by fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD) and scanning electron microscope (SEM).more » In addition, antibacterial activity of the bandage toward Gram positive (Staphylococcus aureus) and Gram negative (Escherichia coli) were also studied. The formation of silver nanoparticles was confirmed by the appearance of LSPR absorption peak at 412.2 – 423.2 nm. Coating of nanocomposite cause increasing rigidity of bandage and decreasing on crystallinity. The bandages of B-Ag/Chit demonstrated good activity against both Gram positive (S. aureus) and Gram negative (E.Coli). Thus the bandages have a potential to be used for antibacterial wound dressing application.« less
Integration of extracellular matrix with chitosan adhesive film for sutureless tissue fixation.
Lauto, Antonio
2009-07-01
Extracellular matrices (ECMs) are currently applied in reconstructive surgery to enhance wound healing and tissue remodelling. Sutures and staples are usually employed to stabilize ECM on tissue although they may damage the matrix structure. In this investigation, a novel biocompatible bandage was developed to fix ECM on tissue without sutures. An adhesive film, based on chitosan, was integrated with small intestine submucosa (SIS) in a single bandage strip. This bandage was bonded to sheep small intestine upon laser irradiation of the chitosan film (P = 0.12 W, Fluence = 46+/-1 J/cm(2)) to assess tissue adhesion strength. Thermocouples were used to estimate temperatures under SIS during laser irradiation. Bandage strips were also mechanically tested to evaluate their tensile strength before and after irradiation. The bandage successfully bonded to intestine achieving a shear stress of 9.6+/- 1.6 kPa (n = 15). During laser irradiation, the temperature increased modestly to 31+/-2 degrees C (n = 14) beneath the ECM portion of the bandage. The bandage withstood a tensile strength of 3,122+/-780 and 3,384+/-791 kPa, before and after laser irradiation respectively (n = 10, P = 0.47, t-test). The SIS-chitosan bandage bonded effectively to tissue without sutures and preserved the ECM structure avoiding irreversible thermal denaturation of imbedded bioactive proteins.
Elastic Multilayer Bandages for Chronic Venous Insufficiency: Features of Our Technique
2012-01-01
Objectives: To evaluate the interface pressure (IP) and stiffness of our elastic multilayer bandages (eMLB). Methods: Three medical staff wrapped the legs of 10 healthy volunteers with one to six rolls of elastic bandages. The IP was measured at the medial aspect of the lower leg at the level of transposition of the medial gastrocnemius muscle into the Achilles tendon (level of B1) with the patient supine and then standing, for each number of bandages worn. The static stiffness index (SSI) was calculated as a difference between these IPs. Results: The IPs in the standing position increased linearly for up to five bandages (21.8 ± 7.2, 32.5 ± 6.1, 41.8 ± 8.5, 52.0 ± 10.4, 60.3 ± 11.8, and 66.7 ± 13.4 mmHg, with one to six bandages). SSI also increased linearly for up to five bandages (6.8 ± 5.1, 10.2 ± 4.8, 13.4 ± 7.2, 17.4 ± 8.8, 19.7 ± 9.1, and 20.4 ± 9.4 mmHg, with one to six bandages). No significant technical variation in the IP was observed among the three operators. Conclusions: Our eMLB provided stable, predictable and sufficient IPs and SSIs in healthy volunteers. PMID:23555535
Bandages and difficulty with bathing: introducing Seal-Tight.
Lindsay, Ellie
2005-06-01
Patients with compression bandages experience difficulty with bathing due to the possibility that bandages may become wet and affect the wound. Bandage and dressing changes resulting from accidental wetting also cost the NHS considerable time and money. This product focus highlights the social and psychological impact on the patient when they are unable to bathe and offers a solution to the problem. Seal-Tight is a product that has been newly placed on the drug tariff, making it widely available to all patients who wear bandages (or plaster casts). Seal-Tight enables the patient to bathe, in some cases for the first time for months or even years.
Deposition of lipid, protein, and secretory phospholipase A2 on hydrophilic contact lenses.
Mochizuki, Hiroshi; Yamada, Masakazu; Hatou, Shin; Kawashima, Motoko; Hata, Seiichiro
2008-01-01
Recent studies have shown that low tear phospholipid levels are associated with tear film instability in hydrophilic contact lens wearers. The concentration of secretory phospholipase A2 (sPLA2), the enzyme that hydrolyzes phospholipids, in tears is known to exceed the levels found in serum by four orders of magnitude. This study was performed to determine the levels of sPLA2 from the deposition on two different frequent-replacement contact lens materials. Polymacon and etafilcon A contact lenses worn for 2 weeks by 16 experienced contact lens wearers were used for the analysis. Total lipids were determined by the sulfo-phospho-vanillin reaction. Phospholipids in lipid extracts were estimated by phosphorus determination with ammonium molybdate through enzymatic digestion. Total protein was measured by bicinchoninic acid analysis. Double-antibody sandwich enzyme-linked immunosorbent assay was used to determine sPLA2 concentrations. Total lipid deposition was found to be greater in the polymacon group (66.3+/-16.3 microg/lens) than in the etafilcon A group, although phospholipids were not detected in either group. The etafilcon A group had greater deposition of protein (3.7+/-0.7 mg/lens) than the polymacon group had. The etafilcon A group deposited statistically significantly more group IIa sPLA2 (1.1+/-0.3 microg/lens) than the polymacon group (0.07+/-0.04 microg/lens) did (P<0.001). There was a significant difference in the lipid and protein deposition profiles in the two lenses tested. A significant amount of sPLA2 in the deposition on contact lenses may play a role in tear film instability in hydrophilic contact lens wearers.
Hart, D E; Plociniak, M P; Grimes, G W
1998-04-01
Historically, biochemical studies of the interaction between tears and hydrogel contact lenses have not been coordinated with the study of the morphological ultrastructure of the phenomena. Moreover, terms that have distinct and different meanings--pellicle, coating, deposit, and biofilm--have been used interchangeably and often incorrectly when applied within the context of the general field of contact lens biotechnology to describe the tear-polymer interaction. We describe our elucidation of morphological and elemental characteristics of the normal pellicle that forms on the lens surface and urge standard use of the word "pellicle" to specify this entity. Fourteen worn hydrogel lenses (8 Group 1 and 6 Group 4 lenses according to the FDA classification) were rinsed, quartered, and fixed or dried, depending on the analysis to be performed. Scanning electron microscopy (SEM) was used to examine the morphology of the pellicle and quantify its thickness. X-ray analysis was used to detect elements associated with the anterior, central, and posterior portions of the lenses and their relative distribution. A distinctive morphological pellicle ranging from 0.1 to 8.6 microns was present on 12 of the 14 lenses. The pellicle was thicker on the Group 4 lenses than on the Group 1 lenses (P < 0.003). However, the pellicle on Group 1 lenses became thicker with increasing lens age (P < 0.02), but not as thick as on Group 4 lenses. Morphologically distinct lipid or jelly bump deposits were observed at the surface of both lenses from a single patient wearing 2 week old Group 4 lenses. Eleven lenses had sulfur-bearing tear components on the anterior zone. Sulfur was deposited within the matrix of nine lenses. The sulfur containing moieties were more prevalent on Group 4 lenses (P < 0.002). More sulfur was assayed on older lenses (P < 0.004). The anterior lens zone had more sulfur-bearing tear components than did the posterior or center zones (P < 0.05). The physiologically normal pellicle is a distinct morphological entity covering the anterior lens surface. Abnormal deposits such as the discrete microgel region, known as jelly bumps, are not part of the physiologically normal pellicle at the anterior lens surface and have the potential to induce pathology. Sulfur-containing moieties within the matrix may represent the breakdown of large proteins and mucoproteins or intact proteins, as well as contaminants such as cosmetics and environmental pollutants. It is also possible that entire small proteins, such as lysozyme, impregnate the matrix. The moieties that become entrapped within the matrix or rigidly adhere to the matrix should be considered true deposits.
Microbial contamination of soft contact lenses & accessories in asymptomatic contact lens users
Thakur, Deeksha V.; Gaikwad, Ujjwala N.
2014-01-01
Background & objectives: With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Methods: Four samples each from 50 participants (n=200) were collected from the lenses, lens care solutions, lens care solution bottles and lens cases along with a questionnaire regarding their lens use. The samples were inoculated onto sheep blood agar, Mac Conkey's agar and Sabouraud's dextrose agar. Organisms were identified using standard laboratory protocols. Results: Overall rate of microbial contamination among the total samples was 52 per cent. The most and the least contaminated samples were found to be lens cases (62%) and lens care solution (42%), respectively. The most frequently isolated contaminant was Staphylococcus aureus (21%) followed by Pseudomonas species (19.5%). Majority (64%) of the participants showed medium grade of compliance to lens cleaning practices. Rate of contamination was 100 and 93.75 per cent respectively in those participants who showed low and medium compliance to lens care practices as compared to those who had high level of compliance (43.75%) (P<0.05). Interpretation & conclusions: Lens care practices amongst the participants were not optimum which resulted into high level contamination. Hence, creating awareness among the users about the lens care practices and regular cleaning and replacements of lens cases are required. PMID:25297366
Influence of Sodium Hyaluronate Concentration on Corneal Aberrations in Soft Contact Lens Wearers
Lee, Jong Soo; Park, Jong Moon; Cho, Hyun Kyung; Kim, Su Jin; Huh, Hyoun Do
2018-01-01
Purpose This study aimed to evaluate the influence of varying concentrations of sodium hyaluronate (SH) eye drops on corneal aberrations in normal individuals wearing silicone hydrogel contact lenses. Methods Normal individuals wearing silicone hydrogel contact lenses were enrolled in this study. Subjects were classified into two groups depending on the concentration of the preservative-free SH used (group 1, 0.1% SH; group 2, 0.3% SH). All subjects were asked to blink five times after instillation of the SH eye drop and before the Galilei measurements. Corneal aberrations were measured over the contact lenses before and after SH eye drop instillation. Visual acuity (VA) over the contact lenses was also measured both before instillation of the SH eye drop and after the subjects completed the five blinks. Results There was no change in VA after SH instillation in group 1; however, group 2's VA significantly deteriorated after SH instillation. Changes in VA after SH instillation compared to baseline were significantly higher in group 2 than in group 1. Similarly, the increase in corneal aberrations after SH instillation was significant in group 2 but not significant in group 1. Among the significantly increased corneal aberration parameters, defocus was the main type in group 2. Changes in corneal aberrations after SH instillation compared to baseline were significantly higher in group 2 than in group 1. Conclusions A 0.3%-concentration of SH increases corneal aberration and decreases VA in soft contact lens wearers. Defocus is the main type of aberration that increased in the 0.3% SH instillation group. PMID:29611370
Aberrations associated with rigid contact lenses.
Atchison, D A
1995-10-01
A rigid contact lens on an eye can produce levels of spherical aberration very different from those produced by a spectacle lens in front of the eye. These levels are considerably affected by contact lens surface asphericity. Change in longitudinal spherical aberration associated with aspherizing a contact lens surface is well predicted by a simple equation for change in sagittal power of the surface. Displacing an aspheric contact lens on the eye can produce considerable defocus, which is well predicted by simple equations for change in sagittal and tangential surface powers. The best refractive correction with contact lenses can be determined only by overrefraction with a patient wearing a contact lens of power and characteristics similar to that which will be prescribed. An aspheric contact lens that moves to a considerable extent on the eye will cause more unstable vision than will a spherical lens that moves to the same extent.
Gabriel, Manal M; McAnally, Cindy; Bartell, John
2018-03-01
The aim of this study was to use antimicrobial efficacy endpoint methodology to determine compatibility of multipurpose disinfecting solutions (MPSs), lens cases, and hydrogel lenses for disinfection (AEEMC) against International Organization for Standardization (ISO)-specified microorganisms and clinical ocular isolates of Stenotrophomonas maltophilia. Six MPSs (PQ/Aldox 1, 2, and 3; PQ/Alexidine; PQ/PHMB; and PHMB) were challenged against ISO-specified microorganisms and S. maltophilia using the AEEMC test. AEEMC tests were performed with and without balafilcon A, etafilcon A, and senofilcon A lenses in lens cases with organic soil. Exposure times included disinfection time (DT) and 24 hr. Additionally, all six MPSs were challenged with two strains of S. maltophilia, based on the ISO Stand-alone test. The efficacy against bacteria for PQ/Aldox and PQ/Alexidine MPSs was not diminished by the presence of lenses. The efficacy of PQ/PHMB and PHMB MPSs against Serratia marcescens was significantly reduced compared with the no-lens control at DT for at least one lens type. The PHMB MPS with lenses present also demonstrated reduced efficacy against Staphylococcus aureus at DT versus the control. PQ/Aldox MPSs retained activity against Fusarium solani with lenses present; however, all other test MPSs demonstrated reduced F. solani efficacy at DT with lenses present. With lenses, all MPSs showed reduced efficacy against Candida albicans. AEEMC antimicrobial efficacy test results vary based on challenge microorganism, contact lenses, and MPS biocide systems. This study highlights the importance of evaluating MPSs for compatibility with lenses and lens cases.
McAnally, Cindy; Bartell, John
2018-01-01
Objective: The aim of this study was to use antimicrobial efficacy endpoint methodology to determine compatibility of multipurpose disinfecting solutions (MPSs), lens cases, and hydrogel lenses for disinfection (AEEMC) against International Organization for Standardization (ISO)–specified microorganisms and clinical ocular isolates of Stenotrophomonas maltophilia. Methods: Six MPSs (PQ/Aldox 1, 2, and 3; PQ/Alexidine; PQ/PHMB; and PHMB) were challenged against ISO-specified microorganisms and S. maltophilia using the AEEMC test. AEEMC tests were performed with and without balafilcon A, etafilcon A, and senofilcon A lenses in lens cases with organic soil. Exposure times included disinfection time (DT) and 24 hr. Additionally, all six MPSs were challenged with two strains of S. maltophilia, based on the ISO Stand-alone test. Results: The efficacy against bacteria for PQ/Aldox and PQ/Alexidine MPSs was not diminished by the presence of lenses. The efficacy of PQ/PHMB and PHMB MPSs against Serratia marcescens was significantly reduced compared with the no-lens control at DT for at least one lens type. The PHMB MPS with lenses present also demonstrated reduced efficacy against Staphylococcus aureus at DT versus the control. PQ/Aldox MPSs retained activity against Fusarium solani with lenses present; however, all other test MPSs demonstrated reduced F. solani efficacy at DT with lenses present. With lenses, all MPSs showed reduced efficacy against Candida albicans. Conclusions: AEEMC antimicrobial efficacy test results vary based on challenge microorganism, contact lenses, and MPS biocide systems. This study highlights the importance of evaluating MPSs for compatibility with lenses and lens cases. PMID:27598555
Myopia correction in children: a meta-analysis.
Cui, Yanhui; Li, Li; Wu, Qian; Zhao, Junyang; Chu, Huihui; Yu, Gang; Wei, Wenbin
2017-06-26
The purpose of this study was to conduct a meta-analysis comparing rigid gas permeable lenses (RGP) with soft contact lenses (SCL), spectacles and orthokeratology (OK) lenses for myopia control with respect to axial length elongation, spherical equivalent and measures of corneal curvature. Medline, Cochrane, EMBASE, and Google Scholar databases were searched to September 29, 2015 using the following keywords: rigid gas permeable contact lens; refractive error; and refractive abnormalities. Randomized controlled trials, two-arm prospective studies and retrospective studies of children with myopia treated with RGP lenses compared with spectacles, SCL, and OK lenses were included. Outcome measures were changes of axial length, spherical equivalent, flatter meridian, steeper meridian and corneal apical radius. Five studies were included. Three studies reported axial length change after 2-3 years of treatment with RGP lenses and SCL/spectacles and no difference between the groups was noted (pooled mean difference = -0.077, 95% confidence interval [CI]: -0.120 to 0.097, p = 0.840). Two studies reported a change of spherical equivalent after 2-3 years of treatment with RGP lenses and SCL/spectacles, and no difference between the groups was noted (pooled mean difference = 0.275, 95% CI: -0.390 to 0.941, p = 0.417). Two studies compared corneal curvature measures between RGP and OK lenses after 3-6 months of treatment and no differences in any measures of corneal curvature were seen. The effect of RGP lenses and SCL/spectacles on axial length elongation and spherical equivalent and of RGP and OK lenses on corneal curvature in children with myopia was similar.
Nomachi, Miya; Sakanishi, Kotaro; Ichijima, Hideji; Cavanagh, H Dwight
2013-05-01
To evaluate the efficacy of a novel daily disposable (DD) flat package in regard to microbial contamination on the anterior and posterior surfaces of a contact lens (CL) during handling of the lens for insertion. Four kinds of commercially available general blister-packed daily disposable contact lenses (DD CLs) as controls and a novel Magic 1-day Menicon Flat Pack as a test lens were used for this in vitro study. Lenses were removed from their packages using fingers coated with fluorescein 3 to 5 μm beads or an approximately 7×10(2) to 2×10(3) colony-forming unit (CFU)/mL Staphylococcus aureus suspension. The transfer of fluorescein beads to the surface of the lenses was then observed by fluorescence microscopy. Microbial contamination on the lenses was observed by light microscopy after a 2-day incubation period; and, the number of colonies isolated from the contaminated lenses was determined after 4 days of incubation. The number of fluorescein beads on the Magic lens was significantly less (p<0.05) than that of the general blister-packed control lenses. Adherence of microbial colonies was observed on both inner and outer surfaces of general blister-packed lenses, whereas no colony formation was found on the inner surface of the Magic lens, and the lowest bacterial adherence was observed for the Magic lens. The data demonstrated that placement of the Magic DD lens onto the eye is accompanied by diminished microbial contamination compared with general blister-packed DD CLs. Eye care professionals; however, should instruct patients to comply with intended use of DD CLs to prevent CL-associated microbial keratitis. In all cases, hand washing is mandated prelens insertion.
Yun, Jun-Won; Hailian, Quan; Na, Yirang; Kang, Byeong-Cheol; Yoon, Jung-Hee; Cho, Eun-Young; Lee, Miri; Kim, Da-Eun; Bae, SeungJin; Seok, Seung Hyeok; Lim, Kyung-Min
2016-12-01
In an effort to explore the use of alternative methods to animal testing for the evaluation of the ocular irritancy of medical devices, we evaluated representative contact lenses with the bovine corneal opacity and permeability test (BCOP) and an in vitro eye irritation test using the three-dimensionally-reconstructed human corneal epithelium (RhCE) models, EpiOcular™ and MCTT HCE™. In addition, we compared the obtained results with the ISO standard in vivo rabbit eye irritation test (ISO10993-10). Along with the positive controls (benzalkonium chloride, BAK, 0.02, 0.2, and 1%), the extracts of 4 representative contact lenses (soft, disposable, hard, and colored lenses) and 2 reference lenses (dye-eluting and BAK-coated lenses) were tested. All the lenses, except for the BAK-coated lens, were determined non-irritants in all test methods, while the positive controls yielded relevant results. More importantly, BCOP, EpiOcular™, and MCTT HCE™ yielded a consistent decision for all the tested samples, with the exception of 0.2% BAK in BCOP, for which no prediction could be made. Overall, all the in vitro tests correlated well with the in vivo rabbit eye irritation test, and furthermore, the combination of in vitro tests as a tiered testing strategy was able to produce results similar to those seen in vivo. These observations suggest that such methods can be used as alternative assays to replace the conventional in vivo test method in the evaluation of the ocular irritancy of ophthalmic medical devices, although further study is necessary. Copyright © 2016. Published by Elsevier Ltd.
Kilvington, Simon; Lonnen, James
2009-04-01
To compare the antimicrobial efficacy of commercial contact lens solutions when used according to the manufacturers' recommended regimens with two types of silicone hydrogel lenses. Four multipurpose contact lens care solutions were examined, representing manufacturer recommended regimens of "rub & rinse", "no rub, rinse" or "no rub, no rinse". Test organisms were Pseudomonas aeruginosa, Serratia marcescens, Staphylococcus aureus, Fusarium solani, Candida albicans and Acanthamoeba castellanii (trophozoites and cysts). Organisms, in the presence of organic soil, were inoculated on to Acuvue Oasys or Air Optix lenses and subjected to the solution manufacturer's recommended regimen. The number of surviving organisms on the lenses and in the soak solution was enumerated in accordance with ISO 14729. ISO 14729 dictates that for a given organism the combined average number of surviving microbes from the lenses and disinfectant soaking solution must be
30 CFR 75.1713-7 - First-aid equipment; location; minimum requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... triangular bandages (15 if a splint-stretcher combination is used). (4) Eight 4-inch bandage compresses; (5) Eight 2-inch bandage compresses. (6) Twelve 1-inch adhesive compresses; (7) One foille; (8) Two cloth...
30 CFR 75.1713-7 - First-aid equipment; location; minimum requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... triangular bandages (15 if a splint-stretcher combination is used). (4) Eight 4-inch bandage compresses; (5) Eight 2-inch bandage compresses. (6) Twelve 1-inch adhesive compresses; (7) One foille; (8) Two cloth...
30 CFR 75.1713-7 - First-aid equipment; location; minimum requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... triangular bandages (15 if a splint-stretcher combination is used). (4) Eight 4-inch bandage compresses; (5) Eight 2-inch bandage compresses. (6) Twelve 1-inch adhesive compresses; (7) One foille; (8) Two cloth...
Towards gecko-feet-inspired bandages.
Yanik, Mehmet Fatih
2009-01-01
A novel bandage inspired by gecko feet might one day be used during emergencies and internal surgeries. The bandage uses a combination of nanofabricated structures, biodegradable materials and adhesive surface chemistry that allows adhesion onto even wet, moving tissue.
30 CFR 75.1713-7 - First-aid equipment; location; minimum requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... triangular bandages (15 if a splint-stretcher combination is used). (4) Eight 4-inch bandage compresses; (5) Eight 2-inch bandage compresses. (6) Twelve 1-inch adhesive compresses; (7) One foille; (8) Two cloth...
Solutions for care of silicone hydrogel lenses.
Willcox, Mark D P
2013-01-01
During wear of contact lenses on a daily wear basis, it is necessary to disinfect the lens overnight before reinserting the lens the next day. The ability of the solutions used for this to disinfect lenses and lens cases is important for safe lens wear. The literature on the disinfecting ability of multipurpose disinfecting solutions (MPDS) commonly used with silicone hydrogel lenses reported during the period 2000 to 2012 is reviewed, as this is the period of time during which these lenses have been commercially available. Particular emphasis is placed on the ability of disinfecting solutions to control colonization of lens cases by microbes and changes in composition and use of the solutions. In addition, the literature is reviewed on ways of minimizing lens case microbial contamination. Maintaining the hygiene of contact lenses and lens cases is important in minimizing various forms of corneal infiltrative events that occur during lens wear. Although lens case contamination is not associated with different lenses, it is determined by use of different MPDS. MPDS that allow more frequent or heavy contamination of cases by Gram-negative bacteria are associated with a higher incidence of corneal infiltrative events. MPDS are now available that contain dual disinfectants. Wiping lens cases with tissues or using lens cases that incorporate silver are associated with reductions in contamination in clinical trials. Similarly, using MPDS to rub and rinse lenses before disinfection may reduce levels of microbes on lenses. The MPDS also contain surfactants that help reduce deposition and denaturation of proteins on lenses. Improvements in MPDS formulations and hygiene practices may help to reduce the incidence of adverse events that are seen during use with silicone hydrogel lenses.
New single-layer compression bandage system for chronic venous leg ulcers.
Lee, Gillian; Rajendran, Subbiyan; Anand, Subhash
A new single-layer bandage system for the treatment of venous leg ulcers has been designed and developed at the University of Bolton. This three-dimensional (3D) knitted spacer fabric structure has been designed by making use of mathematical modelling and Laplace's law. The sustained graduated compression of the developed 3D knitted spacer bandages were tested and characterized, and compared with that of commercially available compression bandages. It was observed that the developed 3D single-layer bandage meets the ideal criteria stipulated for compression therapy. The laboratory results were verified by carrying out a pilot user study incorporating volunteers from different age groups. This article examines the insight into the design and development of the new 3D knitted spacer bandage, along with briefly discussing the issues of compression therapy systems intended for the treatment of venous leg ulcers.
Tear oxygen under hydrogel and silicone hydrogel contact lenses in humans.
Bonanno, Joseph A; Clark, Christopher; Pruitt, John; Alvord, Larry
2009-08-01
To determine the tear oxygen tension under a variety of conventional and silicone hydrogel contact lenses in human subjects. Three hydrogel and five silicone hydrogel lenses (Dk/t = 17 to 329) were coated on the back surface with an oxygen sensitive, bovine serum albumin-Pd meso-tetra (4-carboxyphenyl) porphine complex (BSA-porphine). Each lens type was placed on the right eye of 15 non-contact lens wearers to obtain a steady-state open eye tear oxygen tension using oxygen sensitive phosphorescence decay of BSA-porphine. A closed-eye oxygen tension estimate was obtained by measuring the change in tear oxygen tension after 5 min of eye closure. In separate experiments, a goggle was placed over the lens wearing eye and a gas mixture (PO2 = 51 torr) flowed over the lens to simulate anterior lens oxygen tension during eye closure. Mean open eye oxygen tension ranged from 58 to 133 torr. Closed eye estimates ranged from 11 to 42 torr. Oxygen tension under the goggle ranged from 8 to 48 torr and was higher than the closed eye estimate for six out of the eight lenses, suggesting that the average closed eye anterior lens surface oxygen tension is <51 torr. For Dk/t >30, the measured tear oxygen tension is significantly lower than that predicted from previous studies. The phosphorescence decay methodology is capable of directly measuring the in vivo post lens PO2 of high Dk/t lenses without disturbing the contact lens or cornea. Our data indicate that increasing Dk/t up to and beyond 140 continues to yield increased flux into the central cornea.
Ji, Yong Woo; Cho, Young Joo; Lee, Chul Hee; Hong, Soon Ho; Chung, Dong Yong; Kim, Eung Kweon; Lee, Hyung Keun
2015-01-01
To compare physical characteristics of cosmetic contact lenses (Cos-CLs) and conventional contact lenses (Con-CLs) that might affect susceptibility to bacterial adhesion on the contact lens (CL) surface. Surface characteristics of Cos-CLs and Con-CLs made from the same material by the same manufacturer were measured by atomic force microscopy (AFM) and scanning electron microscopy. To determine the extent and rate of bacterial adhesion, Cos-CL and Con-CL were immersed in serum-free Roswell Park Memorial Institute media containing Staphylococcus aureus or Pseudomonas aeruginosa. Additionally, the rate of removal of adherent bacteria was evaluated using hand rubbing or immersion in multipurpose disinfecting solutions (MPDS). The mean surface roughness (root mean square and peak-to-valley value) measured by AFM was significantly higher for Cos-CL than for Con-CL. At each time point, significantly more S. aureus and P. aeruginosa adhered to Cos-CL than to Con-CL, which correlated with the surface roughness of CL. In Cos-CL, bacteria were mainly found on the tinted surface rather than on the noncolored or convex areas. Pseudomonas aeruginosa attached earlier than S. aureus to all types of CL. However, P. aeruginosa was more easily removed from the surface of CL than S. aureus by hand rubbing or MPDS soaking. Increased surface roughness is an important physical factor for bacterial adhesion in Cos-CL, which may explain why rates of bacterial keratitis rates are higher in Cos-CL users in CL physical characteristics.
Thickness and topographic inspection of RPG contact lenses by optical triangulation
NASA Astrophysics Data System (ADS)
Costa, Manuel F. M.
2001-06-01
Optical triangulation as a non-destructive test method extensively proved its usefulness on the dimensional and topographic inspection of a large range of objects and surfaces. In this communication the issue of microtopographic and thickness inspection of hard contact lenses (RPG) is addressed. The use of optical triangulation is discussed based on the results of the application of our MICROTOP.03.MFC microtopographer to this kind of tasks will be presented.
Stoffels-Weindorf, M; Stoffels, I; Jockenhöfer, F; Dissemond, J
2018-04-01
For effective compression therapy in patients with venous leg ulcers, sufficient pressure is essential. In everyday life, it is often the patients themselves who apply the compression bandages. Many of these patients have restriction in their movement and had been rarely trained adequately. Hence, there was the question of how efficient are the autonomously applied compression bandages of those patients. In all, 100 consecutive patients with venous leg ulcer were asked to apply compression bandages on their own leg. We documented both the achieved compression and formal criteria of correct performance. A total of 59 women and 41 men with an average age of 70.3 years were included in the study. Overall 43 patients were not able to apply a compression bandage because of physical limitations. The measured pressure values in the remaining 57 patients ranged between 6 and 93 mm Hg (mean 28.3 mm Hg). Eleven patients reached the prescribed effective compression pressure. Of these, formal errors were found in 6 patients, so that only 5 patients had correctly applied the compression bandages. Our data show that most patients with venous leg ulcers are not able to apply effective compression therapy with short-stretch bandages to themselves. Multilayer systems, adaptive compression bandages, and ulcer stocking systems today are possibly easier and more effective therapy options. Alternatively short-stretch bandages could be applied by trained persons but only under the control with pressure measuring probes.
Fréalle, E; Rocchi, S; Bacus, M; Bachelet, H; Pasquesoone, L; Tavernier, B; Mathieu, D; Millon, L; Jeanne, M
2018-05-01
Cutaneous mucormycoses, mainly due to Lichtheimia (Absidia), have occurred on several occasions in the Burn Unit of the University Hospital of Lille, France. To investigate the potential vector role of non-sterile bandages used to hold in place sterile gauze used for wound dressing. Mycological analysis by conventional culture, Mucorales real-time polymerase chain reaction (qPCR), and Lichtheimia species-specific qPCR were performed on eight crepe and six elasticized bandages that were sampled on two independent occasions in March 2014 and July 2016. Characteristics of the seven Lichtheimia mucormycoses which occurred in burn patients between November 2013 and July 2016 were also collected to assess the epidemiological relationship between potentially contaminated bandages and clinical infections. One Lichtheimia corymbifera strain was isolated from a crepe bandage by culture, and Lichtheimia spp. qPCR was positive in six out of eight crepe and four out of six elasticized bandages. Using species-specific qPCR, Lichtheimia ramosa, Lichtheimia ornata, and L. corymbifera were identified in six out of ten, five out of ten, and four out of ten bandages, respectively. In patients with mucormycosis, L. ramosa and L. ornata were present in five and two cases, respectively. Our data support the utility of Mucorales qPCR for epidemiological investigations, the potential role of these bandages in cutaneous mucormycoses in burn patients in our centre, and, consequently, the need for sterile bandages for the dressing of extensive wounds. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Gause, Samuel; Hsu, Kuan-Hui; Shafor, Chancellor; Dixon, Phillip; Powell, Kristin Conrad; Chauhan, Anuj
2016-07-01
Ophthalmic drug for the anterior chamber diseases are delivered into tears by either eye drops or by extended release devices placed in the eyes. The instilled drug exits the eye through various routes including tear drainage into the nose through the canaliculi and transport across various ocular membranes. Understanding the mechanisms relevant to each route can be useful in predicting the dependency of ocular bioavailability on various formulation parameters, such as drug concentration, salinity, viscosity, etc. Mathematical modeling has been developed for each of the routes and validated by comparison with experiments. The individual models can be combined into a system model to predict the fraction of the instilled drug that reaches the target. This review summarizes the individual models for the transport of drugs across the cornea and conjunctiva and the canaliculi tear drainage. It also summarizes the combined tear dynamics model that can predict the ocular bioavailability of drugs instilled as eye drops. The predictions from the individual models and the combined model are in good agreement with experimental data. Both experiments and models predict that the corneal bioavailability for drugs delivered through eye drops is less than 5% due to the small area of the cornea in comparison to the conjunctiva, and the rapid clearance of the instilled solution by tear drainage. A contact lens is a natural choice for delivering drugs to the cornea due to the placement of the contact in the immediate vicinity of the cornea. The drug released by the contact towards the cornea surface is trapped in the post lens tear film for extended duration of at least 30min allowing transport of a large portion into the cornea. The model predictions backed by in vivo animal and clinical data show that the bioavailability increases to about 50% with contact lenses. This realization has encouraged considerable research towards delivering ocular drugs by contact lenses. Commercial contacts are, however, not ideal for drug delivery due to the short release durations which may necessitate wearing multiple lenses each day, reducing the viability of this approach. Recent research has focused on designing contacts that retain all critical properties while increasing the release durations to a few hours or a few days. Beagle dog studies with contact lenses containing vitamin E nanobarriers to attenuate drug transport have shown promising results. Human studies using contacts for drug delivery have also been conducted for allergy therapy but drug eluting contacts are not available in the market for any therapy. Copyright © 2015 Elsevier B.V. All rights reserved.
A Long Term Study of the Water Content Changes in Three Types of Hydrogel Contact Lenses.
1987-05-01
7RD-R1BS 579 A LONG TERM STUDY OF THE HATER CONTENT CHANGES IN THREE 1/2 TYPES OF HYDROGEL ..(U) AIR FORCE INST OF TECH URIGHT-PATTERSON AFI OH L 0...The Water Content Changes THESIS/Dl$$XF$T$77q Ln ~In Three Types Of Hydrogel Contact Lenses G EFRIGI EOTNME IO 7. AUTHOR(.) S. CONTRACT OR GRANT NUMBER...SECURITY CLASSIFICATION OF THIS PAGE ("o~tn Date Entered) ABSTRACT A" Sufficient oxygen is required to pass through a hydrogel contact lens for proper
Surface interactions on hydrogel contact lenses: scanning electron microscopy (SEM).
Hart, D E
1987-12-01
SEM was used to visualize tear-film/hydrogel polymer surface interactions. Lenses were preserved by fixation including a quaternary ammonium complex to aid in mucin preservation. In less than 2 weeks of continuous wear the anterior surface was completely coated, yet the coating was absent from the posterior lens surface. Tear-film break-up over the deposited lens surface, combined with degradation and deformation at the polymer surface boundary, as well as entrapment of moieties within the polymer matrix, all occurred. These are the likely culprits which can contribute to adverse reactions as well as cause light scatter and diminished vision. Lenses removed directly from the eyes of patients suffering with different forms of conjunctivitis were obtained. Bacterial and viral conjunctivitis can induce a microbially contaminated as well as a heavily deformed and deposited lens. Viable and intact microbes were not typically observed in the mucoprotein layer of hydrogel contact lenses.
Pearson, Richard
2011-03-01
To assess the possibility of estimating the refractive index of rigid contact lenses on the basis of measurements of their back vertex power (BVP) in air and when immersed in liquid. First, a spreadsheet model was used to quantify the magnitude of errors arising from simulated inaccuracies in the variables required to calculate refractive index. Then, refractive index was calculated from in-air and in-liquid measurements of BVP of 21 lenses that had been made in three negative BVPs from materials with seven different nominal refractive index values. The power measurements were made by two operators on two occasions. Intraobserver reliability showed a mean difference of 0.0033±0.0061 (t = 0.544, P = 0.59), interobserver reliability showed a mean difference of 0.0043±0.0061 (t = 0.707, P = 0.48), and the mean difference between the nominal and calculated refractive index values was -0.0010±0.0111 (t = -0.093, P = 0.93). The spreadsheet prediction that low-powered lenses might be subject to greater errors in the calculated values of refractive index was substantiated by the experimental results. This method shows good intra and interobserver reliabilities and can be used easily in a clinical setting to provide an estimate of the refractive index of rigid contact lenses having a BVP of 3 D or more.
Tierney, Jayne; Cullum, Nicky; Bland, J Martin; Franks, Peter J; Mole, Trevor; Scriven, Mark
2009-01-01
Objective To compare the effectiveness of two types of compression treatment (four layer bandage and short stretch bandage) in people with venous leg ulceration. Design Systematic review and meta-analysis of patient level data. Data sources Electronic databases (the Cochrane Central Register of Controlled Trials, the Cochrane Wounds Group Specialised Register, Medline, Embase, CINAHL, and National Research Register) and reference lists of retrieved articles searched to identify relevant trials and primary investigators. Primary investigators of eligible trials were invited to contribute raw data for re-analysis. Review methods Randomised controlled trials of four layer bandage compared with short stretch bandage in people with venous leg ulceration were eligible for inclusion. The primary outcome for the meta-analysis was time to healing. Cox proportional hazards models were run to compare the methods in terms of time to healing with adjustment for independent predictors of healing. Secondary outcomes included incidence and number of adverse events per patient. Results Seven eligible trials were identified (887 patients), and patient level data were retrieved for five (797 patients, 90% of known randomised patients). The four layer bandage was associated with significantly shorter time to healing: hazard ratio (95% confidence interval) from multifactorial model based on five trials was 1.31 (1.09 to 1.58), P=0.005. Larger ulcer area at baseline, more chronic ulceration, and previous ulceration were all independent predictors of delayed healing. Data from two trials showed no evidence of a difference in adverse event profiles between the two bandage types. Conclusions Venous leg ulcers in patients treated with four layer bandages heal faster, on average, than those of people treated with the short stretch bandage. Benefits were consistent across patients with differing prognostic profiles. PMID:19376798
Oxygen permeability of the pigmented material used in cosmetic daily disposable contact lenses
Galas, Stephen; Copper, Lenora L
2016-01-01
Purpose To evaluate the individual contributions of pigment colorant and packing solution containing polyvinyl pyrrolidone (PVP) on the oxygen permeability (Dk) of a cosmetic printed etafilcon A daily disposable contact lens packaged with PVP. Method The oxygen transport of a contact lens is evaluated through the central optical zone of the lens. Cosmetic printed contact lenses contain pigment colorant in the periphery or mid-periphery of the lens. Therefore, to assess the impact of cosmetic print on oxygen permeability, special lenses need to be produced that contain the colorant within the central optical zone. This technique was used to obtain multiple measurements of nonedge-corrected Dk/t of both the center pigmented lens and its nonpigmented equivalent, using a polarographic measurement described in International Organization for Standardization (ISO) 18369-4:2006(E), and the Dk derived for each measurement is corrected for edge effect. In addition, the edge-corrected Dk values of lenses made from the same monomer batch were measured. The lenses were packaged and autoclaved with and without proprietary technology which embeds PVP in the contact lens during autoclaving. The resulting Dk value of the printed lens material was then used with thickness data to generate true Dk/t profiles for a given lens power. Results The edge-corrected Dk of the printed etafilcon A lens with offset pigment colorant was measured to be 19.7×10−11 (cm2/s) (mL O2/mL·mmHg) at 35°C. This was within ±20% tolerance range as specified in ISO 18369-2:2012(E) for the edge-corrected Dk of the nonpigmented etafilcon A control lens evaluated during the same session, 19.5×10−11 (cm2/s) (mL O2/mL·mmHg). The edge-corrected Dk values of the lenses packaged with PVP (mean 20.1, standard deviation [SD] 0.3) were also within the ±20% tolerance range compared to those packaged without PVP (mean 20.0, SD 0.3). Conclusion The pigment colorant and PVP embedded in the contact lens during autoclaving were not found to influence the oxygen permeability of the etafilcon A material. PMID:28003735
Maciejewska, Magdalena; Bauer, Marta; Neubauer, Damian; Kamysz, Wojciech; Dawgul, Malgorzata
2016-01-01
The widespread use of contact lenses is associated with several complications, including ocular biofilm-related infections. They are very difficult to manage with standard antimicrobial therapies, because bacterial growth in a biofilm is associated with an increased antibiotic resistance. The principal aim of this study was to evaluate the efficacy of antimicrobial peptides (AMPs) in eradication of bacterial biofilms formed on commercially available contact lenses. AMPs were synthesized according to Fmoc/tBu chemistry using the solid-phase method. Minimum inhibitory concentration (MIC) and minimum biofilm eradication concentration (MBEC) of the compounds were determined. Anti-biofilm activity of the antimicrobial peptides determined at different temperatures (25 °C and 37 °C) were compared with the effectiveness of commercially available contact lens solutions. All of the tested compounds exhibited stronger anti-biofilm properties as compared to those of the tested lens solutions. The strongest activity of AMPs was noticed against Gram-positive strains at a temperature of 25 °C. Conclusions: The results of our experiments encourage us toward further studies on AMPs and their potential application in the prophylaxis of contact lens-related eye infections. PMID:28773992
Chaidaroon, Winai; Supalaset, Sumet
2016-01-01
To describe corneal ring infiltrates caused by Serratia marcescens in a patient with human immunodeficiency virus (HIV-1) who wore contact lenses. A case study of a patient with keratitis due to an infection caused by S. marcescens and exhibiting corneal ring infiltrates was reviewed for history, clinical manifestation, microscopic study, and management. A 29-year-old man who had a history of contact lens wear and HIV-1 infection was admitted to hospital because of blurred vision, redness, and corneal infiltrates in the shape of a ring in the left eye. The visual acuity (VA) in both eyes was hand movement (uncorrected). Corneal scrapings were performed. The culture results of the corneal specimens revealed S. marcescens . The culture results of the contact lens disclosed the same organism. The corneal ulcer responded well to treatment with topical gentamycin sulfate 14 mg/ml. The final VA remained hand movement. S. marcescens can cause ring infiltrates in a HIV-1 patient who wears contact lenses. The treatment result for S. marcescens keratitis in a HIV-1 patient who wore contact lenses was favorable after intensive use of fortified topical antibiotics.
Mechanically triggered solute uptake in soft contact lenses.
Tavazzi, Silvia; Ferraro, Lorenzo; Fagnola, Matteo; Cozza, Federica; Farris, Stefano; Bonetti, Simone; Simonutti, Roberto; Borghesi, Alessandro
2015-06-01
Molecular arrangement plays a role in the diffusion of water and solutes across soft contact lenses. In particular, the uptake of solutes in hydrated contact lenses can occur as long as free water is available for diffusion. In this work, we investigated the effect of mechanical vibrations of low frequency (200 Hz) on the solute uptake. Hyaluronan, a polysaccharide of ophthalmic use, was taken as example of solute of interest. For a specific water-hydrated hydrogel material, differential scanning calorimetry experiments showed that a large fraction of the hydration water accounted for loosely-bound water, both before and after one week of daily-wear of the lenses. The size (of the order of magnitude of few hundreds of nanometers) of hyaluronan in aqueous solution was found to be less than the size of the pores of the lens observed by scanning electron microscopy. However, solute uptake in already-hydrated lenses was negligible by simple immersion, while a significant increase occurred under mechanical vibrations of 200 Hz, thus providing experimental evidence of mechanically triggered enhanced solute uptake, which is attributed to the release of interfacial loosely-bound water. Also other materials were taken into consideration. However, the effectiveness of mechanical vibrations for hyaluronan uptake is restricted to lenses containing interfacial loosely-bound water. Indeed, loosely-bound water is expected to be bound to the polymer with bonding energies of the order of magnitude of 10-100 J/g, which are compatible with the energy input supplied by the vibrations. Copyright © 2015 Elsevier B.V. All rights reserved.
Fentem, P H; Goddard, M; Gooden, B A; Yeung, C K
1976-01-01
A study was performed to determine whether the pressures routinely produced by bandaging for compression sclerotherapy of varicose veins are adequate to maintain the superfical veins almost empty of blood. The results suggest that well-applied bandages can provide sufficient support to combat the high distending pressures found in varicose veins. The large variation among different surgeons, however, indicates that any clinical assessment of compression sclerotherapy should include measurement of the pressure at which the bandages are applied. PMID:974569
Expansive cements for the manufacture of the concrete protective bandages
NASA Astrophysics Data System (ADS)
Yakymechko, Yaroslav; Voloshynets, Vladyslav
2017-12-01
One of the promising directions of the use of expansive cements is making the protective bandages for the maintenance of pipelines. Bandages expansive application of the compositions of the pipeline reinforce the damaged area and reduce stress due to compressive stress in the cylindrical area. Such requirements are best suited for expansive compositions obtained from portland cement and modified quicklime. The article presents the results of expansive cements based on quick lime in order to implement protective bandages pipelines.
Contact lens deposits, adverse responses, and clinical ocular surface parameters.
Zhao, Zhenjun; Naduvilath, Thomas; Flanagan, Judith L; Carnt, Nicole A; Wei, Xiaojia; Diec, Jennie; Evans, Vicki; Willcox, Mark D P
2010-09-01
To correlate clinical responses during contact lens wear with the amount of protein or cholesterol extracted from lenses after wear. Clinical parameters, including adverse response rates and corneal staining, and symptomatology rating during lens wear were collected from a series of clinical tests comprising four different silicone hydrogel lenses with four different multipurpose solutions. To test for correlates, the amount of total protein or cholesterol extracted from lenses after daily wear were compared statistically to clinical parameters. The amount of protein (p = 0.008) or cholesterol (p = 0.01) extracted from lenses was higher for those subjects who showed solution-induced corneal staining. Amount of protein extracted was correlated (p < 0.01) with conjunctival staining (R = -0.23), lens front surface wetting (r = 0.14), and lens fit tightness (R = -0.20). These clinical parameters accounted for 48% of lens protein deposition. The amount of cholesterol extracted from lenses was much more weakly associated with clinical variables. Amount of protein or cholesterol extracted from lenses was not associated with the production of any corneal infiltrative or mechanical adverse event during wear and was only very weakly correlated with insertion comfort of lenses. These results suggest that there may be no physiologically relevant consequence of cholesterol depositing on silicone hydrogel lenses. The amount of protein that deposits onto silicone hydrogel lenses during wear may have more affect on lens performance on-eye. However, the correlations were generally small and may still not indicate any causative relevant physiological response. Further work is required to determine whether there is any direct causative effect to support these correlative findings.
Phosphorylcholine impairs susceptibility to biofilm formation of hydrogel contact lenses.
Selan, Laura; Palma, Stefano; Scoarughi, Gian Luca; Papa, Rosanna; Veeh, Richard; Di Clemente, Daniele; Artini, Marco
2009-01-01
To compare silicone-hydrogel, poly(2-hydroxyethyl methacrylate) (pHEMA), and phosphorylcholine-coated (PC-C) contact lenses in terms of their susceptibility to biofilm formation by Staphylococcus epidermidis and Pseudomonas aeruginosa. Laboratory investigation. Biofilm formation on colonized test lenses was evaluated with confocal microscopy and in vitro antibiotic susceptibility assays. The results of the latter assays were compared with those performed on planktonic cultures of the same organism. For both microorganisms, sessile colonies on silicone-hydrogel and pHEMA lenses displayed lower antibiotic susceptibility than their planktonic counterparts. In contrast, the susceptibility of cultures growing on PC-C lenses was comparable with that for planktonic cultures. In particular, minimum inhibitory concentration for Tazocin (piperacillin plus tazobactam; Wyeth Pharmaceuticals, Aprilia, Italy; S. epidermidis) and gentamicin (P. aeruginosa) was identical, either in the presence of PC-C support or in planktonic cultures (Tazocin, = 0.2 mug/ml; gentamicin, 0.4 mug/ml). Minimum inhibitory concentration for imipenem (P. aeruginosa) was two-fold higher for PC-C lenses (0.4 mug/ml) with respect to planktonic cultures (0.2 mug/ml). Confocal microscopy of lenses colonized for 24 hours with P. aeruginosa green fluorescent protein-expressing cells revealed a sessile colonization on silicone-hydrogel lens and a few isolated bacterial cells scattered widely over the surface of the PC-C lens. An increase in antibiotic susceptibility of bacterial cultures was associated with diminished bacterial adhesion. Our results indicate that PC-C lenses seem to be more resistant than silicone-hydrogel and pHEMA lenses to bacterial adhesion and colonization. This feature may facilitate their disinfection.
Kasseroller, Renato G; Brenner, Erich
2010-03-01
Breast-cancer-related lymphoedema, either caused by the tumour itself or its therapy, can be found in approximately 24% of all patients. It results in disabilities, psychological distress and reduced quality of life. Therefore, proper therapy for this entity is very important. Guidelines recommend a therapy in two phases, an intensive phase I for 3 weeks for volume reduction and, between the cycles of phase I, a reduced phase II to maintain the result. During phase I therapy, manual lymphatic drainage often cannot be administered on weekends or holidays; only a reduced therapy, mainly by application of a more or less passive compression by bandaging, is administered. For this, conventional low-stretch bandages are hitherto being used. Several attempts have been made to overcome this disadvantage by either impregnating or covering the bandage with sticky or adhesive substances such as india rubber, elastomeres, polyacrylates, etc. Recently, new bandages are available, which are drenched with alginate that becomes semi-rigid after drying for approximately 6 h. It was the aim of this study to compare alginate bandaging to a conventional lymphologic-multilayered low-stretch bandaging with individual supportive lining as to their effect concerning their congestive capacity in exactly delimited time periods of reduced decongestive therapy as well as the patients' tolerance. From December 2007 until May 2008, 61 female patients with a one-sided lymphoedema of the axillary tributary region after axillar dissection who underwent a phase I complex decongestive therapy were prospectively selected for our investigation. On weekends, group A got the conventional low-stretch compressive bandaging, whereas group B got an alginate semi-rigid bandage. Arm volumes were measured before and after these bandages were applied. Additionally, the subjective sensations of the skin caused by the compression were measured by means of a five-level Likert scale. The initial volumes (V (0)) of the two groups (A, 2,939.0 ml +/- 569.182; B, 3,062.6 ml +/- 539.161) varied within the same magnitude, with somewhat smaller values in group A. The same was true for the final volumes (V (6)), measured at day 22 (A, 2,674.5 ml +/- 480.427; B, 2,740.1 ml +/- 503.593). During the weekends, the arm volumes re-increased (first weekend: A, 16.4 ml vs. B, 4.7 ml; second weekend: A, 14.2 ml vs. B, 2.7 ml; third weekend: A, 7.5 ml vs. B, 1.1 ml). A significantly smaller volume increase appeared in the alginate group during the weekends. There were no serious side effects in both groups. Concerning the patients' comfort, the values of the alginate group were clearly better than those of the conventionally bandaged group. Additionally, the volume changes in the alginate group revealed fewer fluctuations. As a summary, one can state that a good alternative to the conventional bandaging is available with the alginate bandages, bringing distinct advantages for the patients when administered properly.
The fate of eyewear in aircraft ejections.
O'Connell, S R; Markovits, A S
1995-02-01
Ejection from jet aircraft has been exhaustively studied from many perspectives; e.g., causes of ejection, types and causes of ejection injuries, etc. Curiously, no reports exist describing the fate of eyewear in ejections. Many pilots wear required corrective lenses during flight operations, and many wear tinted lenses. What happens to these during ejection? What injuries are a result of the eyewear? What factors can be identified that influence retention of the eyewear and severity of related injury? Do contact lenses provide significant advantages? There were 48 ejections occurring between 1977 and 1990 that involved corrective or tinted lens use that were retrospectively examined using Naval Safety Center records and personal questionnaires. There were five contact lens wearers included. Retention rates were calculated as functions of several variables. Although 37 of 46 lost all lenses, each instance of retention occurred with visor down, oxygen mask on, helmet properly secured, and at lower ejection speeds. Related injuries were minor and occurred in only 20%. The utility and need for enforcement of standard operating procedures (i.e., mask on, helmet secured, and visor down) was clearly demonstrated. Only 19 of 46 clearly met all 3 criteria. Contact lens users were too few to allow meaningful conclusions.
Dumbleton, Kathryn; Keir, Nancy; Moezzi, Amir; Feng, Yunwei; Jones, Lyndon; Fonn, Desmond
2006-10-01
Silicone hydrogel (SiH) lenses offer many physiological advantages for daily wear (DW) in addition to the continuous-wear modality for which they were originally developed. The purpose of this study was to investigate the clinical performance and physiological responses in a group of successful long-term wearers of conventional hydrogel lenses when refitted with DW SiH contact lenses. Eighty-seven successful soft lens wearers (8.4+/-4.7 years of prior lens wear) participated in this study. Bulbar and limbal hyperemia were subjectively graded and digitally photographed for subsequent masked objective evaluation. Subjective symptoms were scored using visual analog scales. In addition, refractive error, corneal curvature, and corneal thickness were measured. All subjects were refitted with Focus Night & Day (lotrafilcon A) SiH lenses; however, to reduce the potential for bias, they were informed that they were being randomly assigned to wear either low oxygen permeability (Dk) lenses or high Dk SiH lenses and were "masked" as to their lens assignment. Subjects returned after 1 week, 1 month, and 2 months of DW, at which time all gradings, photographs, and measurements were repeated. End-of-day subjective symptoms were also graded periodically during the study. Ninety-three percent of subjects were successfully refitted. Both objective and subjective evaluations showed that bulbar and limbal hyperemia decreased significantly in all quadrants during the study (p<0.001), particularly for those subjects with greater baseline hyperemia (p<0.001). Subjects reported a concurrent reduction in end-of-day dryness and improved end-of-day comfort compared with their habitual lenses (p<0.001). No significant changes in refractive error, tarsal papillary response, corneal curvature, or corneal thickness were found during the study. Hyperemia in contact lens wearers may be attributed to a number of factors, including hypoxia. Refitting existing low Dk lens wearers with SiH lenses on a DW basis can result in a decrease in hyperemia, which may be significant for some subjects and also results in improvements in symptoms of dryness and discomfort.
An Experimental Model to Study the Impact of Lipid Oxidation on Contact Lens Deposition In Vitro.
Schuett, Burkhardt S; Millar, Thomas J
2017-09-01
This study was to establish a controlled in vitro test system to study the effect of lipid oxidation on lipid deposition on contact lenses. Fatty acids with varying degree of unsaturation were oxidized using the Fenton reaction. The degree of lipid oxidation and the lipid moieties formed during the oxidation were identified and estimated by various lipid staining techniques following separation with thin-layer chromatography, and by measuring thiobarbituric acid reactive substances or peroxides in solution. Two different silicone hydrogel-based contact lenses (Balafilcon A and Senofilcon A) were incubated with fatty acids laced with radioactive tracer oxidized to varying degrees, and the amount of lipid deposition was measured using unoxidized lipid samples as controls. The Fenton reaction together with the analytical methods to analyze the lipid oxidation can be used to control oxidation of lipids to a desired amount. In general, saturated fatty acids are not oxidized, the monounsaturated oleic acid produced peroxides while poly-unsaturated lipids initially produced peroxides and then fragmented into reactive aldehydes. Incubation with mildly oxidized lipids (most likely lipid peroxides) resulted in increased lipid deposition on Balafilcon A lenses compared to unoxidized lipids, but this was not observed for Senofilcon A lenses. Further oxidation of the lipids (carbon chain breakup) on the other hand resulted in diminished lipid deposition for both contact lens types. This study provides a method for inducing and controlling lipid oxidation so that the effect of lipid oxidation on contact lens binding can be compared. It could be shown that the degree of lipid oxidation has different effects on the lipid deposition on different contact lens types.
A patellar bandage improves mobility but not static balance in elderly female fallers.
Scheicher, Marcos Eduardo; Fonseca, Ligia Cristiane Santos; Bortolloto, Tiago Buso; de Carvalho, Isabela Feitosa
2018-04-01
The deterioration in the somatosensory and motor systems observed with increasing age can cause balance problems. Studies have shown that the use of infrapatellar bandages can enhance proprioception and improve postural balance. To evaluate the effect of an infrapatellar bandage on static balance and mobility in elderly female fallers and non-fallers. Forty older women (20 fallers and 20 non-fallers) were evaluated. Mobility (Timed Up and Go test) and balance (force platform) were measured in the presence and absence of additional sensory information (elastic infrapatellar bandage). Mobility differed in fallers (p = 0.0001), but not in non-fallers (p = 0.27), when the patellar bandage was applied. Additional sensory information did not improve static balance in either group (p > 0.05), but a trend towards improvement was observed in fallers. Additional sensory input from an infrapatellar bandage improves mobility but not bipedal stance in elderly fallers. Copyright © 2017 Elsevier Ltd. All rights reserved.
The safety and efficacy of contact lens wear in the industrial and chemical workplace.
Tyhurst, Keith; McNett, Ryan; Bennett, Edward
2007-11-01
The use and safety of contact lenses in the industrial and chemical workplace has often been questioned since the 1960s because of many unconfirmed reports of ocular injury resulting from contact lens wear. Because of these urban legends, contact lens wear has been banned or wearers have been required to wear additional personal protective equipment (PPE) not required of non-contact lens wearers. Literature review via Medline and Google search. Research has shown that contact lenses typically provide protective benefits that decrease the severity of ocular injury and improve worker performance. While contact lens wear contraindications do exist, in most cases, and with proper precautions, contact lens wear is still possible. Industrial and chemical companies need to establish written contact lens use policies based on current studies that have shown the safety of workplace contact lens wear when combined with the same PPE required of non-contact lens wearers. Practitioners need to discuss, with their contact lens patients, the additional responsibilities required to maintain proper lens hygiene and proper PPE in the workplace.
Chromatic confocal microscope using hybrid aspheric diffractive lenses
NASA Astrophysics Data System (ADS)
Rayer, Mathieu; Mansfield, Daniel
2014-05-01
A chromatic confocal microscope is a single point non-contact distance measurement sensor. For three decades the vast majority of the chromatic confocal microscope use refractive-based lenses to code the measurement axis chromatically. However, such an approach is limiting the range of applications. In this paper the performance of refractive, diffractive and Hybrid aspheric diffractive are compared. Hybrid aspheric diffractive lenses combine the low geometric aberration of a diffractive lens with the high optical power of an aspheric lens. Hybrid aspheric diffractive lenses can reduce the number of elements in an imaging system significantly or create large hyper- chromatic lenses for sensing applications. In addition, diffractive lenses can improve the resolution and the dynamic range of a chromatic confocal microscope. However, to be suitable for commercial applications, the diffractive optical power must be significant. Therefore, manufacturing such lenses is a challenge. We show in this paper how a theoretical manufacturing model can demonstrate that the hybrid aspheric diffractive configuration with the best performances is achieved by step diffractive surface. The high optical quality of step diffractive surface is then demonstrated experimentally. Publisher's Note: This paper, originally published on 5/10/14, was replaced with a corrected/revised version on 5/19/14. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance.
Myopia Control with Bifocal Contact Lenses: A Randomized Clinical Trial.
Aller, Thomas A; Liu, Maria; Wildsoet, Christine F
2016-04-01
Most studies have reported only minimal reductions in myopia progression with bifocal or progressive multifocal spectacles, although somewhat larger, although mostly still clinically insignificant, effects have been reported in children with nearpoint esophoria and/or accommodative dysfunctions. The CONTROL study was a 1-year, prospective, randomized, clinical trial of bifocal contact lenses for control of myopia in children with eso fixation disparities at near. Eighty-six myopic subjects, aged 8 to 18 years, were enrolled in the study after passing the screening examination. Of these, 79 completed lens assignment and 78 completed the study. The mean refractive error of these 79 subjects was -2.69 ± 1.40D (SD), and all had progressed by -0.50D or more since their last examination. All subjects also had eso fixation disparity at near. Subjects were randomly assigned to wear either Vistakon Acuvue 2 (single-vision soft contact lenses [SVSCLs]) or Vistakon Acuvue Bifocal (bifocal soft contact lenses [BFSCLs]). Bifocal adds were selected to neutralize the associated phoria. Treatment outcomes included cycloplegic autorefraction and axial length, assessed in terms of changes after 6 and 12 months of treatment from pretreatment baseline values. The BFSCLs significantly slowed myopia progression, with statistically significant differences between the treatment groups after 6 months. After 12 months of treatment, the SVSCL group had progressed by -0.79 ± 0.43D compared with -0.22 ± 0.34D for the BFSCL group (cycloplegic objective spherical equivalent, average of two eyes). Corresponding axial length changes were 0.24 ± 0.17 mm and 0.05 ± 0.14 mm, respectively. All of these differences were found to be statistically significant (unpaired t-tests, p < 0.001). The distance center bifocal contact lenses tested in this study achieved greater control over myopia progression and axial elongation (>70%) compared with most published results with multifocal spectacles. Further studies are warranted to identify the critical factors and mechanisms underlying this myopia control effect.
Risk Factors for Contact Lens Bacterial Contamination During Continuous Wear
Szczotka-Flynn, Loretta B.; Bajaksouzian, Saralee; Jacobs, Michael R.; Rimm, Alfred
2009-01-01
Purpose Microbial contamination of contact lenses is associated with corneal infection and inflammation. This study determined which microbiological, clinical and demographic factors are associated with bacterial contamination of a silicone hydrogel contact lens when worn for continuous wear. Methods Two hundred five normal subjects were enrolled in the Longitudinal Analysis of Silicone Hydrogel (LASH) Contact Lens Study and were fitted with lotrafilcon A lenses for monthly continuous wear and followed for 1 year. Lenses were aseptically removed after 1 week and 4 months of wear and cultured using an agar sandwich technique. Lids and conjunctiva were routinely cultured at baseline, and after 1 week and 4 months of continuous wear. Lenses and ocular sites were considered to have substantial microbial bioburden when they harbored pathogenic organisms or high levels of commensal organisms. Univariate and multivariate logistic regression analyses were conducted to examine whether substantial conjunctival or lid bioburden, subject demographics, lens wearing history, symptoms, and biomicroscopic signs were associated with lens bioburden. Results About one-third (32.4%) of subjects had substantial bacterial bioburden in either eye across multiple visits. Over half (53.2%) and about one-tenth (11.7%) of subjects had substantial lid and conjunctival bioburden, respectively, and 11.2% discontinued due to discomfort. The adjusted odds ratios (and 95% confidence intervals) for presence of substantial lens bioburden were 2.49 (1.17–5.30), 4.24 (1.45–12.40), and 4.11 (1.17–14.46) for substantial lid bioburden, substantial conjunctival bioburden, and lens discomfort, respectively. Conclusions Bacterial contamination of silicone hydrogel contact lenses is common during continuous wear. Substantial lens bioburden is associated with discomfort precluding successful continuous wear. The presence of substantial lid and conjunctival bioburden are associated with a 2.5 fold and over 4 fold greater risk of substantial lens bioburden and are likely the major routes of contamination. PMID:19786927
Tear Oxygen Under Hydrogel and Silicone Hydrogel Contact Lenses in Humans
Bonanno, Joseph A.; Clark, Christopher; Pruitt, John; Alvord, Larry
2011-01-01
Purpose To determine the tear oxygen tension under a variety of conventional and silicone hydrogel contact lenses in human subjects. Methods Three hydrogel and five silicone hydrogel lenses (Dk/t = 17 to 329) were coated on the back surface with an oxygen sensitive, bovine serum albumin-Pd meso-tetra (4-carboxyphenyl) porphine complex (BSA-porphine). Each lens type was placed on the right eye of 15 non-contact lens wearers to obtain a steady-state open eye tear oxygen tension using oxygen sensitive phosphorescence decay of BSA-porphine. A closed-eye oxygen tension estimate was obtained by measuring the change in tear oxygen tension after 5 min of eye closure. In separate experiments, a goggle was placed over the lens wearing eye and a gas mixture (PO2 = 51 torr) flowed over the lens to simulate anterior lens oxygen tension during eye closure. Results Mean open eye oxygen tension ranged from 58 to 133 torr. Closed eye estimates ranged from 11 to 42 torr. Oxygen tension under the goggle ranged from 8 to 48 torr and was higher than the closed eye estimate for six out of the eight lenses, suggesting that the average closed eye anterior lens surface oxygen tension is <51 torr. For Dk/t >30, the measured tear oxygen tension is significantly lower than that predicted from previous studies. Conclusions The phosphorescence decay methodology is capable of directly measuring the in vivo post lens PO2 of high Dk/t lenses without disturbing the contact lens or cornea. Our data indicate that increasing Dk/t up to and beyond 140 continues to yield increased flux into the central cornea. PMID:19609230
Pauné, J; Queiros, A; Quevedo, L; Neves, H; Lopes-Ferreira, D; González-Méijome, J M
2014-12-01
To evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes. Ten right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refraction was measured using a Grand Seiko open-field autorefractometer across the central 60° of the horizontal visual field. Ocular aberrations were measured with a Hartman-Shack aberrometer, and monocular contrast sensitivity function (CSF) was measured with a VCTS6500 without and with the three contact lenses. Both experimental lenses were able to increase significantly the relative peripheral myopic defocus up to -0.50 D in the nasal field and -1.00 D in the temporal field (p<0.05). The ExpRGP induced a significantly higher myopic defocus in the temporal field compared to the ExpSCL. ExpSCL induced significantly lower levels of Spherical-like HOA than ExpRGP for the 5mm pupil size (p<0.05). Both experimental lenses kept CSF within normal limits without any statistically significant change from baseline (p>0.05). RGP lens design seems to be more effective to induce a significant myopic change in the relative peripheral refractive error. Both lenses preserve a good visual performance. The worsened optical quality observed in ExpRGP was due to an increased coma-like and spherical-like HOA. However, no impact on the visual quality as measured by CSF was observed. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Effects of Aviation Altitudes on Soft Contact Lens Wear.
1986-08-01
with corneal edema may complain of foggy or hazy vision, discomfort, and injection of the conjunctiva (3). If the edema is severe, breakdown of some of...13 L-.. , 4 .F -A % ,Z;: Z’,-1,’ 15. Brennan, N. A. A simple instrument for measuring the water content of hydrogel lenses. International Contact...vertical striae accompanying the wearing of hydrogel lenses. Am J Op tor & Physiol Optics 52(3):185-191 (1975). 23. Hill, R. H. Oxygen demand: The
30 CFR 77.1707 - First aid equipment; location; minimum requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... this paragraph (b) (2)); (3) Twenty-four triangular bandages (15 if a splint-stretcher combination is used); (4) Eight 4-inch bandage compresses; (5) Eight 2-inch bandage compresses; (6) Twelve 1-inch adhesive compresses; (7) An approved burn remedy; (8) Two cloth blankets; (9) One rubber blanket or...
30 CFR 77.1707 - First aid equipment; location; minimum requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... this paragraph (b) (2)); (3) Twenty-four triangular bandages (15 if a splint-stretcher combination is used); (4) Eight 4-inch bandage compresses; (5) Eight 2-inch bandage compresses; (6) Twelve 1-inch adhesive compresses; (7) An approved burn remedy; (8) Two cloth blankets; (9) One rubber blanket or...
30 CFR 77.1707 - First aid equipment; location; minimum requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... this paragraph (b) (2)); (3) Twenty-four triangular bandages (15 if a splint-stretcher combination is used); (4) Eight 4-inch bandage compresses; (5) Eight 2-inch bandage compresses; (6) Twelve 1-inch adhesive compresses; (7) An approved burn remedy; (8) Two cloth blankets; (9) One rubber blanket or...
30 CFR 77.1707 - First aid equipment; location; minimum requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... this paragraph (b) (2)); (3) Twenty-four triangular bandages (15 if a splint-stretcher combination is used); (4) Eight 4-inch bandage compresses; (5) Eight 2-inch bandage compresses; (6) Twelve 1-inch adhesive compresses; (7) An approved burn remedy; (8) Two cloth blankets; (9) One rubber blanket or...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... maintained contents in the specified quantities: Contents Quantity Adhesive bandage compresses, 1-inch 16 Antiseptic swabs 20 Ammonia inhalants 10 Bandage compresses, 4-inch 8 Triangular bandage compresses, 40-inch...
Risk factors for microbial bioburden during daily wear of silicone hydrogel contact lenses.
Jiang, Ying; Jacobs, Michael; Bajaksouzian, Saralee; Foster, Altreisha N; Debanne, Sara M; Bielefeld, Roger; Garvey, Matt; Raghupathy, Sangeetha; Kern, Jami; Szczotka-Flynn, Loretta B
2014-05-01
To assess risk factors associated with substantial microbial bioburden of lids, conjunctivae, contact lenses, and storage cases during daily wear of silicone hydrogel contact lenses. Two hundred eighteen patients were fit to lotrafilcon A lenses, randomized to use either a multipurpose solution or a hydrogen peroxide care system, and followed up for 1 year. Lenses, lens transport saline, lids, conjunctivae, and storage cases were cultured and considered to have substantial microbial bioburden when they harbored high levels of commensal or pathogenic organisms. Univariate and multivariate logistic regression analyses were conducted to examine which demographic covariates were associated with significant bioburden at each location while controlling for solution use. In multivariate analyses, smoking trended toward an association with lens bioburden (odds ratio [OR]=2.15, 95% confidence interval [CI]: 0.95-4.88). Clerical occupations were found to be associated with more frequent overall storage case contamination (OR=3.51, 95% CI: 1.15-10.70) and, specifically, higher gram-positive storage case contamination (OR=5.57, 95% CI: 1.82-17.06). The peroxide system was associated with more frequent storage case contamination (OR=7.6, 95% CI: 3.79-15.19). Coagulase-negative staphylococci (CNS) were the most frequently cultured organisms within storage cases, and in multivariate analyses, CNS were more frequently found in storage cases of peroxide users (OR=6.12, 95% CI: 2.91-13.09). Clerical occupations were associated with increased microbial bioburden of storage cases during daily wear of silicone hydrogel lenses. Smoking may increase the risk of lens contamination. Storage cases are most frequently contaminated with normal skin flora, and peroxide cases were associated with more frequent contamination. However, the solution type was not associated with lid or lens contamination nor with corneal infiltrative events in this study.
Carracedo, Gonzalo; González-Méijome, José Manuel; Pintor, Jesús
2012-07-03
To evaluate the levels of dinucleotides diadenosine tetraphosphate (Ap(4)A) and diadenosine pentaphosphate (Ap(5)A) in tears of patients wearing rigid gas permeable (RGP) contact lenses on a daily wear basis and of patients wearing reverse-geometry RGP lenses overnight for orthokeratology treatment. Twenty-two young volunteers (10 females, 12 males; 23.47 ± 4.49 years) were fitted with an alignment-fit RGP lens (paflufocon B) for a month, and after a 15-day washout period they were fitted with reverse-geometry RGP lenses for corneal reshaping (paflufocon D) for another month. During each period, tears were collected at baseline day 1, 7, 15, and 28. Ap(4)A and Ap(5)A were measured by high-pressure liquid chromatography (HPLC). Additionally, corneal staining, break-up time (BUT), Schirmer test, and dryness symptoms were evaluated. Ap(4)A concentrations increased significantly from baseline during the whole period of daily wear of RGP lenses (P < 0.001); concentration was also significantly higher than in the orthokeratology group, which remained at baseline levels during the study period except at day 1 (P < 0.001) and day 28 (P = 0.041). While BUT and Schirmer remained unchanged in both groups, discomfort and dryness were significantly increased during alignment-fit RGP daily wear but not during the orthokeratology period. Daily wear of RGP lenses increased the levels of Ap(4)A due to mechanical stimulation by blinking of the corneal epithelium, and this is associated with discomfort. Also, orthokeratology did not produce symptoms or signs of ocular dryness, which could be a potential advantage over soft contact lenses in terms of contact lens-induced dryness.
Contact-eutectic-lens fabrication technique
NASA Technical Reports Server (NTRS)
Allen, F. G.; Yue, A. S.; Yu, J. G.
1975-01-01
Method enables use of crystal or semiconductor materials with selective spectral-response characteristics (ultraviolet, visible, or infrared wavelengths) in fabrication of contact lenses, reading glasses, and photographic processing equipment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... contact lens fitting. Ophthalmic goods are contact lenses, eyeglasses, or any component of eyeglasses. Ophthalmic services are the measuring, fitting, and adjusting of ophthalmic goods subsequent to an eye...
Code of Federal Regulations, 2010 CFR
2010-01-01
... contact lens fitting. Ophthalmic goods are contact lenses, eyeglasses, or any component of eyeglasses. Ophthalmic services are the measuring, fitting, and adjusting of ophthalmic goods subsequent to an eye...
Code of Federal Regulations, 2012 CFR
2012-01-01
... contact lens fitting. Ophthalmic goods are contact lenses, eyeglasses, or any component of eyeglasses. Ophthalmic services are the measuring, fitting, and adjusting of ophthalmic goods subsequent to an eye...
Code of Federal Regulations, 2011 CFR
2011-01-01
... contact lens fitting. Ophthalmic goods are contact lenses, eyeglasses, or any component of eyeglasses. Ophthalmic services are the measuring, fitting, and adjusting of ophthalmic goods subsequent to an eye...
Code of Federal Regulations, 2014 CFR
2014-01-01
... contact lens fitting. Ophthalmic goods are contact lenses, eyeglasses, or any component of eyeglasses. Ophthalmic services are the measuring, fitting, and adjusting of ophthalmic goods subsequent to an eye...
21 CFR 886.5928 - Soft (hydrophilic) contact lens care products.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (hydrophilic) contact lens. This includes all solutions and tablets used together with soft (hydrophilic) contact lenses and heat disinfecting units intended to disinfect a soft (hydrophilic) contact lens by means of heat. (b) Classification. Class II (Special Controls) Guidance Document: “Guidance for Industry...
21 CFR 886.5928 - Soft (hydrophilic) contact lens care products.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (hydrophilic) contact lens. This includes all solutions and tablets used together with soft (hydrophilic) contact lenses and heat disinfecting units intended to disinfect a soft (hydrophilic) contact lens by means of heat. (b) Classification. Class II (Special Controls) Guidance Document: “Guidance for Industry...
21 CFR 886.5928 - Soft (hydrophilic) contact lens care products.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (hydrophilic) contact lens. This includes all solutions and tablets used together with soft (hydrophilic) contact lenses and heat disinfecting units intended to disinfect a soft (hydrophilic) contact lens by means of heat. (b) Classification. Class II (Special Controls) Guidance Document: “Guidance for Industry...
21 CFR 886.5928 - Soft (hydrophilic) contact lens care products.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (hydrophilic) contact lens. This includes all solutions and tablets used together with soft (hydrophilic) contact lenses and heat disinfecting units intended to disinfect a soft (hydrophilic) contact lens by means of heat. (b) Classification. Class II (Special Controls) Guidance Document: “Guidance for Industry...
Santos, Lívia; Rodrigues, Diana; Lira, Madalena; Oliveira, Rosario; Real Oliveira, M Elisabete C D; Vilar, Eva Yebra-Pimentel; Azeredo, Joana
2007-05-01
In this study, the effect of the natural surfactants octylglucoside and sodium cholate in inhibiting Staphylococcus epidermidis and Pseudomonas aeruginosa adhesion to conventional and silicone-hydrogel contact lenses (CL) was assessed. Hydrophobicity was also evaluated to conditioned and nonconditioned CL. The inhibiting effect of the tested surfactants was determined through "in vitro" adhesion studies to conditioned and nonconditioned CL followed by image acquisition and cell enumeration. Hydrophobicity was evaluated through contact angle measurements using the advancing type technique on air. Sodium cholate exhibits a very low capability to inhibit microbial adhesion. Conversely, octylglucoside effectively inhibited microbial adhesion in both types of lenses. This surfactant exhibited an even greater performance than a multipurpose lens care solution used as control. Octylglucoside was the only tested surfactant able to lower the hydrophobicity of all CL, which can explain its high performance. The results obtained in this study point out the potential of octylglucoside as a conditioning agent to prevent microbial colonization.
Accommodation and the Visual Regulation of Refractive State in Marmosets
Troilo, David; Totonelly, Kristen; Harb, Elise
2009-01-01
Purpose To determine the effects of imposed anisometropic retinal defocus on accommodation, ocular growth, and refractive state changes in marmosets. Methods Marmosets were raised with extended-wear soft contact lenses for an average duration of 10 wks beginning at an average age of 76 d. Experimental animals wore either a positive or negative contact lens over one eye and a plano lens or no lens over the other. Another group wore binocular lenses of equal magnitude but opposite sign. Untreated marmosets served as controls and three wore plano lenses monocularly. Cycloplegic refractive state, corneal curvature, and vitreous chamber depth were measured before, during, and after the period of lens wear. To investigate the accommodative response, the effective refractive state was measured through each anisometropic condition at varying accommodative stimuli positions using an infrared refractometer. Results Eye growth and refractive state are significantly correlated with the sign and power of the contact lens worn. The eyes of marmosets reared with monocular negative power lenses had longer vitreous chambers and were myopic relative to contralateral control eyes (p<0.01). Monocular positive power lenses produced a significant reduction in vitreous chamber depth and hyperopia relative to the contralateral control eyes (p<0.05). In marmosets reared binocularly with lenses of opposite sign, we found larger interocular differences in vitreous chamber depths and refractive state (p<0.001). Accommodation influences the defocus experienced through the lenses, however, the mean effective refractive state was still hyperopia in the negative-lens-treated eyes and myopia in the positive-lens-treated eyes. Conclusions Imposed anisometropia effectively alters marmoset eye growth and refractive state to compensate for the imposed defocus. The response to imposed hyperopia is larger and faster than the response to imposed myopia. The pattern of accommodation under imposed anisometropia produces effective refractive states that are consistent with the changes in eye growth and refractive state observed. PMID:19104464
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-28
... County, Florida; Extension of Subzone; Aso LLC (Adhesive Bandage Manufacturing); Sarasota County, FL An... for the manufacture of adhesive bandages under FTZ procedures (Board Order 1120, 65 FR 58508-58509, 9... used various duty suspension provisions on adhesive tape. Aso is now requesting to indefinitely extend...
Anjana, J; Mohandas, Annapoorna; Seethalakshmy, S; Suresh, Maneesha K; Menon, Riju; Biswas, Raja; Jayakumar, R
2018-04-15
Chronic diabetic wounds is characterised by increased microbial contamination and overproduction of matrix metalloproteases that would degrade the extracellular matrix. A bi-layer bandage was developed, that promotes the inhibition of microbial infections and matrix metalloprotease (MMPs) activity. Bi-layer bandage containing benzalkonium chloride loaded gelatin nanoparticles (BZK GNPs) in chitosan-Hyaluronic acid (HA) as a bottom layer and sodium alendronate containing chitosan as top layer was developed. We hypothesized that the chitosan-gelatin top layer with sodium alendronate could inhibit the MMPs activity, whereas the chitosan-HA bottom layer with BZK GNPs (240±66nm) would enable the elimination of microbes. The porosity, swelling and degradation nature of the prepared Bi-layered bandage was studied. The bottom layer could degrade within 4days whereas the top layer remained upto 7days. The antimicrobial activity of the BZK NPs loaded bandage was determined using normal and clinical strains. Gelatin zymography shows that the proteolytic activity of MMP was inhibited by the bandage. Copyright © 2017 Elsevier B.V. All rights reserved.
Development of the Contact Lens User Experience: CLUE Scales
Wirth, R. J.; Edwards, Michael C.; Henderson, Michael; Henderson, Terri; Olivares, Giovanna; Houts, Carrie R.
2016-01-01
ABSTRACT Purpose The field of optometry has become increasingly interested in patient-reported outcomes, reflecting a common trend occurring across the spectrum of healthcare. This article reviews the development of the Contact Lens User Experience: CLUE system designed to assess patient evaluations of contact lenses. CLUE was built using modern psychometric methods such as factor analysis and item response theory. Methods The qualitative process through which relevant domains were identified is outlined as well as the process of creating initial item banks. Psychometric analyses were conducted on the initial item banks and refinements were made to the domains and items. Following this data-driven refinement phase, a second round of data was collected to further refine the items and obtain final item response theory item parameters estimates. Results Extensive qualitative work identified three key areas patients consider important when describing their experience with contact lenses. Based on item content and psychometric dimensionality assessments, the developing CLUE instruments were ultimately focused around four domains: comfort, vision, handling, and packaging. Item response theory parameters were estimated for the CLUE item banks (377 items), and the resulting scales were found to provide precise and reliable assignment of scores detailing users’ subjective experiences with contact lenses. Conclusions The CLUE family of instruments, as it currently exists, exhibits excellent psychometric properties. PMID:27383257
Latanoprost-Eluting Contact Lenses in Glaucomatous Monkeys.
Ciolino, Joseph B; Ross, Amy E; Tulsan, Rehka; Watts, Amy C; Wang, Rong-Fang; Zurakowski, David; Serle, Janet B; Kohane, Daniel S
2016-10-01
To assess the ability of latanoprost-eluting contact lenses to lower the intraocular pressure (IOP) of glaucomatous eyes of cynomolgus monkeys. Preclinical efficacy study of 3 treatment arms in a crossover design. Female cynomolgus monkeys with glaucoma induced in 1 eye by repeated argon laser trabeculoplasty. Latanoprost-eluting low-dose contact lenses (CLLO) and high-dose contact lenses (CLHI) were produced by encapsulating a thin latanoprost-polymer film within the periphery of a methafilcon hydrogel, which was lathed into a contact lens. We assessed the IOP-lowering effect of CLLO, CLHI, or daily latanoprost ophthalmic solution in the same monkeys. Each monkey consecutively received 1 week of continuous-wear CLLO, 3 weeks without treatment, 5 days of latanoprost drops, 3 weeks without treatment, and 1 week of continuous-wear CLHI. On 2 consecutive days before initiation of each study arm, the IOP was measured hourly over 7 consecutive hours to establish the baseline IOP. Two-tailed Student t tests and repeated-measures analysis of variance were used for statistical analysis. Intraocular pressure. Latanoprost ophthalmic solution resulted in IOP reduction of 5.4±1.0 mmHg on day 3 and peak IOP reduction of 6.6±1.3 mmHg on day 5. The CLLO reduced IOP by 6.3±1.0, 6.7±0.3, and 6.7±0.3 mmHg on days 3, 5, and 8, respectively. The CLHI lowered IOP by 10.5±1.4, 11.1±4.0, and 10.0±2.5 mmHg on days 3, 5, and 8, respectively. For the CLLO and CLHI, the IOP was statistically significantly reduced compared with the untreated baseline at most time points measured. The CLHI demonstrated greater IOP reduction than latanoprost ophthalmic solution on day 3 (P = 0.001) and day 5 (P = 0.015), and at several time points on day 8 (P < 0.05). Sustained delivery of latanoprost by contact lenses is at least as effective as delivery with daily latanoprost ophthalmic solution. More research is needed to determine the optimal continuous-release dose that would be well tolerated and maximally effective. Contact lens drug delivery may become an option for the treatment of glaucoma and a platform for ocular drug delivery. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Myopia and radial keratotomy: a survey among Norwegian ophthalmologists.
Midelfart, A
1990-10-01
One hundred and eighty-nine of 200 ophthalmologists in Norway responded to a survey requesting them to report their age, sex, refractive state, use of corrective lenses, and if myopic, their view on radial keratotomy as a possible method to correct their own myopia. According to the answers, 32 (17%) females and 154 (82%) males, with mean age of 49 years, were registered. The reported refractive state was 26.5% emmetropy and 72.0% ametropy. The prevalence of myopia was 45%. The mean refractive status (equivalent sphere) in the right eye was -1.02 +/- 2.28 D with a range from -8.5 D to +7.25 D (n = 184). Of the ametropes, 64.8% used spectacles, 15.3% used both spectacles and contact lenses, whilst 3.6% used only contact lenses for distance vision. With the exception of one, all myopes used corrective lenses. Only 2 myopic ophthalmologists responded positively to the question of whether they would consider having radial keratotomy to correct their own myopia.
The FDA role in contact lens development and safety.
Lippman, R E
1990-01-01
The Food and Drug Administration (FDA) exercises a multifaceted role in fulfilling its mission of enforcing the Federal Food, Drug and Cosmetic Act (Act), functioning not only as industry regulator and consumer protector, but also as scientific advisor and consumer educator regarding medical devices, drugs, foods, cosmetics, and veterinary medicine. Medical devices are regulated within the Center for Devices and Radiological Health. Contact lenses are regulated under the authority of the medical device amendments. The Center is responsible for promulgating regulations, publishing guidelines, and developing written guidance in enforcing the Act, and also for guiding manufacturers of medical devices in safe and effective product development. Other components deal with the compliance of manufacturers with the marketing of medical devices within the meaning of the Act, and through labeling requirements of the Act and consumer education and informational activities. As for contact lenses, the process of updating product development regulations and guidelines is an ongoing activity. The most recent version of the Contact Lens Guideline Document, issued in April 1988, contains two major revisions involving preclinical and clinical testing. The first redefines plastics into one materials category, thus reducing testing requirements with respect to animal toxicology studies and other preclinical areas. The second revision restricts clinical testing requirements to allow confirmatory trials in applications for new daily wear lenses. The intention was to maintain the ability of studies to detect major material or design flaws in lenses, thus boosting confidence in their performance while eliminating unnecessary trials.(ABSTRACT TRUNCATED AT 250 WORDS)
Miñones Conde, M; Conde, O; Trillo, J M; Miñones, J
2011-04-05
Mixed monolayers of poly(methyl methacrylate) (PMMA), the main component of hard contact lenses, and dipalmitoyl phosphatidyl choline (DPPC), a characteristic phospholipidic constituent of ocular tear films, were selected as an in vitro model in order to observe the behavior of contact lenses on the eye. Using Langmuir monolayer and Brewster angle microscopy (BAM) techniques, the interaction between both components was analyzed from the data of surface pressure-area isotherms, compressional modulus-surface pressure, and relative film thickness versus time elapsed from the beginning of compression, together with BAM images. Regardless of the surface pressure at which the molecular/monomer areas (A(m)) were recorded, the A(m) mole fractions of PMMA (X(PMMA)) plots show that the experimental results match the theoretical values calculated from additivity rule A(m) = X(PMMA)A(PMMA) + X(DPPC)A(DPPC). The application of the Crisp phase rule to the phase diagram of the PMMA-DPPC system can explain the existence of a mixed monolayer made up of miscible components with ideal behavior at surface pressures below 25 mN/m. However, at very high surface pressures, when collapse is reached (at 60 mN/m), the single collapsed components are segregated into two independent phases. These results allows us to argue that PMMA hard contact lenses in the eye do not alter the structural characteristics of the phospholipid (DPPC) in tears.
25G compared with 20G vitrectomy under Resight non-contact wide-angle lenses for Terson syndrome.
Mao, Xinbang; You, Zhipeng
2017-08-01
The aim of the present study was to compare the effectiveness of 25G vitrectomy to standard 20G vitrectomy for treatment of Terson syndrome under Resight non-contact wide-angle lenses. This was a case-control study of 20 patients with Terson syndrome (study group) that underwent 25G vitrectomy under Resight non-contact wide-angle lenses, with those of 20 matched patients that underwent 20G vitrectomy (control group). Medical records were reviewed from between July 2011 and October 2013. Data included results of the Early Treatment Diabetic Retinopathy Study examination, ophthalmology B-scan ultrasonography and fundus photography. The mean age, follow-up time, the preoperative visual acuity of LogMAR and the preoperative intraocular pressure (IOP) were all comparable in the two groups (all P>0.05). There were statistically significant differences in postoperative visual acuity of LogMAR compared with preoperative visual acuity (P<0.001) in both groups, but no difference between the groups (P=0.845). However, the operative times (13.5 min in study group vs. 42 min in control group) and post-operative IOP at day 1 (13.5 vs. 20 mmHg) were significantly reduced in the study group compared to the control group (P<0.001). Therefore, the present findings suggest that 25G Vitrectomy for Terson syndrome under Resight non-contact wide-angle lenses can achieve a significantly shorter operative time and lower post-operative IOP compared with 20G Vitrectomy.
Compression therapy in mixed ulcers increases venous output and arterial perfusion.
Mosti, Giovanni; Iabichella, Maria Letizia; Partsch, Hugo
2012-01-01
This study was conducted to define bandage pressures that are safe and effective in treating leg ulcers of mixed arterial-venous etiology. In 25 patients with mixed-etiology leg ulcers who received inelastic bandages applied with pressures from 20 to 30, 31 to 40, and 41 to 50 mm Hg, the following measurements were performed before and after bandage application to ensure patient safety throughout the investigation: laser Doppler fluxmetry (LDF) close to the ulcer under the bandage and at the great toe, transcutaneous oxygen pressure (TcPo(2)) on the dorsum of the foot, and toe pressure. Ejection fraction (EF) of the venous pump was performed to assess efficacy on venous hemodynamics. LDF values under the bandages increased by 33% (95% confidence interval [CI], 17-48; P < .01), 28% (95% CI, 12-45; P < .05), and 10% (95% CI, -7 to 28), respectively, under the three pressure ranges applied. At toe level, a significant decrease in flux of -20% (95% CI, -48 to 9; P < .05) was seen when bandage pressure >41 mm Hg. Toe pressure values and TcPo(2) showed a moderate increase, excluding a restriction to arterial perfusion induced by the bandages. Inelastic bandages were highly efficient in improving venous pumping function, increasing the reduced ejection fraction by 72% (95% CI, 50%-95%; P < .001) under pressure of 21 to 30 mm Hg and by 103% (95% CI, 70%-128%; P < .001) at 31 to 40 mm Hg. In patients with mixed ulceration, an ankle-brachial pressure index >0.5 and an absolute ankle pressure of >60 mm Hg, inelastic compression of up to 40 mm Hg does not impede arterial perfusion but may lead to a normalization of the highly reduced venous pumping function. Such bandages are therefore recommended in combination with walking exercises as the basic conservative management for patients with mixed leg ulcers. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Mosti, Giovanni; Crespi, Aldo; Mattaliano, Vincenzo
2011-05-01
Compression therapy is standard treatment for venous leg ulcers. The authors prefer multi-layer, multi-component, stiff, high-pressure bandages to treat venous leg ulcers. The Unna boot (UB) is an example of this type of bandage. The aim of this study was to compare the effectiveness and tolerability of UB to a new, two-component bandage. One hundred (100) patients with venous ulcers were randomized into two groups: group A (n = 50) received UB and group B (n = 50) 3M™ Coban™ 2 Layer Compression System (C2L). All patients were followed weekly for 3 months and then monthly until complete healing was achieved. The primary outcomes were: ulcer healing or surface reduction; pain; and exudate control. The secondary outcomes were: ease of application and removal of the bandage, pressure exerted in the supine and standing position after application and before removal, and bandage comfort. C2L was associated with 100% ulcer healing; 47 out of 50 cases healed within the first 3 months after application of the bandage. Compared with the UB, there was no statistically significant difference. In both groups the effect of compression on pain and overall well being was excellent; pain decreased by 50% within 1-2 weeks and remained low throughout the duration of treatment and overall well being improved significantly. There was no significant difference between the two systems concerning level of comfort. C2L proved to be effective in treating venous ulcers due to its stiffness and pressure. Its effectiveness was similar to UB, which is often considered the gold-standard compression device for venous ulcers. This fact, in combination with high tolerability and ease of application and removal, make this new bandage particularly suitable for the treatment of venous leg ulcers. .
Non-invasive pre-lens tear film assessment with high-speed videokeratoscopy.
Llorens-Quintana, Clara; Mousavi, Maryam; Szczesna-Iskander, Dorota; Iskander, D Robert
2018-02-01
To evaluate the effect of two types of daily contact lenses (delefilcon A and omafilcon A) on the tear film and establish whether it is dependent on pre-corneal tear film characteristics using a new method to analyse high-speed videokeratoscopy recordings, as well as to determine the sensitivity of the method in differentiating between contact lens materials on eye. High-speed videokeratoscopy recordings were analysed using a custom made automated algorithm based on a fractal dimension approach that provides a set of parameters directly related to tear film stability. Fifty-four subjects participated in the study. Baseline measurements, in suppressed and natural blinking conditions, were taken before subjects were fitted with two different daily contact lenses and after four hours of contact lens wear. The method for analysing the stability of the tear film provides alternative parameters to the non-invasive break up time to assess the quality of the pre-corneal and pre-lens tear film. Both contact lenses significantly decreased the quality of the tear film in suppressed and natural blinking conditions (p<0.001). The utilised method was able to distinguish between contact lens materials on eye in suppressed blinking conditions. The pre-corneal tear film characteristics were not correlated with the decrease in pre-lens tear film quality. High-speed videokeratoscopy equipped with an automated method to analyse the dynamics of the tear film is able to distinguish between contact lens materials in vivo. Incorporating the assessment of pre-lens tear film to the clinical practice could aid improving contact lens fitting and understand contact lens comfort. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Control of Hazards to Health From Laser Radiation
2006-01-01
compared to the calculated AEL. (2) Optically aided viewing. Viewing a laser beam with optical aids (other than ordinary eyeglasses or contact lenses ...resonant optical cavity. TB MED 524 8 b. Lenses , mirrors, cooling systems, shutters, and other accessories may be added to the system to obtain...procedures for laser optical systems (for example, mirrors, prisms, and lenses ) that employ Class 2 and Class 3a lasers, it is always good laser safety
Focus-tunable low-power electrowetting lenses with thin parylene films.
Watson, Alexander M; Dease, Kevin; Terrab, Soraya; Roath, Christopher; Gopinath, Juliet T; Bright, Victor M
2015-07-10
Electrowetting lenses with record low power consumption (microwatts) have been demonstrated using high-quality parylene AF-4 dielectric layers and large dodecyl sulfate ions. Water and propylene glycol are interchanged as the polar liquid to enable diverging and converging lens operation achievable with the application of 15 V. The optical quality of the lenses is comparable to conventional microlenses and the tuning exhibits very little (<0.5°) contact angle hysteresis.
Adhesion of Pseudomonas aeruginosa to orthokeratology and alignment lenses.
Choo, Jennifer D; Holden, Brien A; Papas, Eric B; Willcox, Mark D P
2009-02-01
To determine whether contact lenses designed for orthokeratology (OK) are colonized by greater numbers of bacteria compared with standard (alignment fitted) design rigid gas permeable lenses before and after lens wear. Eighteen 1-year-old cats were randomly fitted with an OK lens in one eye and an alignment fitted (AF) lens in the other eye. Both lenses were made in the same diameter and central thickness and of the same material. Two separate wearing periods of 2 weeks and 6 weeks were used. After each wearing period, lenses were soaked in Pseudomonas aeruginosa (6294 or 6206) for 10 min. The lenses were then reinserted onto their respective corneas for a wearing period of 16 hours after which lenses were collected and remaining adhered bacteria quantified. Unworn control lenses were also soaked and bacteria enumerated for comparison. There were no significant differences in the number of bacteria adherent to unworn AF and OK lenses. Analysis of lenses after wear showed OK lenses retained significantly higher numbers of viable bacteria than AF lenses in all studies. OK lenses retain more bacteria than AF rigid gas permeable lenses after bacteria-loaded overnight lens wear. This may increase the risk for an infection in OK patients should suitable conditions be present. Specific education on the cleaning of OK lenses is essential.
Protein deposition on a lathe-cut silicone hydrogel contact lens material.
Subbaraman, Lakshman N; Woods, Jill; Teichroeb, Jonathan H; Jones, Lyndon
2009-03-01
To determine the quantity of total protein, total lysozyme, and the conformational state of lysozyme deposited on a novel, lathe-cut silicone hydrogel (SiHy) contact lens material (sifilcon A) after 3 months of wear. Twenty-four subjects completed a prospective, bilateral, daily-wear, 9-month clinical evaluation in which the subjects were fitted with a novel, custom-made, lathe-cut SiHy lens material. The lenses were worn for three consecutive 3-month periods, with lenses being replaced after each period of wear. After 3 months of wear, the lenses from the left eye were collected and assessed for protein analysis. The total protein deposited on the lenses was determined by a modified Bradford assay, total lysozyme using Western blotting and the lysozyme activity was determined using a modified micrococcal assay. The total protein recovered from the custom-made lenses was 5.3 +/- 2.3 microg/lens and the total lysozyme was 2.4 +/- 1.2 microg/lens. The denatured lysozyme found on the lenses was 1.9 +/- 1.0 microg/lens and the percentage of lysozyme denatured was 80 +/- 10%. Even after 3 months of wear, the quantity of protein and the conformational state of lysozyme deposited on these novel lens materials was very similar to that found on similar surface-coated SiHy lenses after 2 to 4 weeks of wear. These results indicate that extended use of the sifilcon A material is not deleterious in terms of the quantity and quality of protein deposited on the lens.
49 CFR 228.331 - First aid and life safety.
Code of Federal Regulations, 2014 CFR
2014-10-01
... (at least 4 × 4 inches); (2) Two large gauze pads (at least 8 × 10 inches); (3) Two adhesive bandages; (4) Two triangular bandages; (5) One package of gauge roller bandage that is at least 2 inches wide... of tweezers; (9) One roll of adhesive tape; (10) Two pairs of latex gloves; and (11) One...
49 CFR 228.331 - First aid and life safety.
Code of Federal Regulations, 2013 CFR
2013-10-01
... (at least 4 × 4 inches); (2) Two large gauze pads (at least 8 × 10 inches); (3) Two adhesive bandages; (4) Two triangular bandages; (5) One package of gauge roller bandage that is at least 2 inches wide... of tweezers; (9) One roll of adhesive tape; (10) Two pairs of latex gloves; and (11) One...
49 CFR 228.331 - First aid and life safety.
Code of Federal Regulations, 2012 CFR
2012-10-01
... (at least 4 x 4 inches); (2) Two large gauze pads (at least 8 x 10 inches); (3) Two adhesive bandages; (4) Two triangular bandages; (5) One package of gauge roller bandage that is at least 2 inches wide... of tweezers; (9) One roll of adhesive tape; (10) Two pairs of latex gloves; and (11) One...
Changes in the Eye Microbiota Associated with Contact Lens Wearing
Price, Kenneth; Albert, Luong; Dodick, Jack; Park, Lisa
2016-01-01
ABSTRACT Wearing contact lenses has been identified as a risk factor for the development of eye conditions such as giant papillary conjunctivitis and keratitis. We hypothesized that wearing contact lenses is associated with changes in the ocular microbiota. We compared the bacterial communities of the conjunctiva and skin under the eye from 58 subjects and analyzed samples from 20 subjects (9 lens wearers and 11 non-lens wearers) taken at 3 time points using a 16S rRNA gene-based sequencing technique (V4 region; Illumina MiSeq). We found that using anesthetic eye drops before sampling decreases the detected ocular microbiota diversity. Compared to those from non-lens wearers, dry conjunctival swabs from lens wearers had more variable and skin-like bacterial community structures (UniFrac; P value = <0.001), with higher abundances of Methylobacterium, Lactobacillus, Acinetobacter, and Pseudomonas and lower abundances of Haemophilus, Streptococcus, Staphylococcus, and Corynebacterium (linear discriminant analysis [LDA] score = >3.0). The results indicate that wearing contact lenses alters the microbial structure of the ocular conjunctiva, making it more similar to that of the skin microbiota. Further research is needed to determine whether the microbiome structure provides less protection from ocular infections. PMID:27006462
Improvements in Topical Ocular Drug Delivery Systems: Hydrogels and Contact Lenses.
Ribeiro, Andreza Maria; Figueiras, Ana; Veiga, Francisco
2015-01-01
Conventional ophthalmic systems present very low corneal systemic bioavailability due to the nasolacrimal drainage and the difficulty to deliver the drug in the posterior segment of ocular tissue. For these reasons, recent advances have focused on the development of new ophthalmic drug delivery systems. This review provides an insight into the various constraints associated with ocular drug delivery, summarizes recent findings in soft contact lenses (SCL) and the applications of novel pharmaceutical systems for ocular drug delivery. Among the new therapeutic approaches in ophthalmology, SCL are novel continuous-delivery systems, providing high and sustained levels of drugs to the cornea. The tendency of research in ophthalmic drug delivery systems development are directed towards a combination of several technologies (bio-inspired and molecular imprinting techniques) and materials (cyclodextrins, surfactants, specific monomers). There is a tendency to develop systems which not only prolong the contact time of the vehicle at the ocular surface, but also at the same time slow down the clearance of the drug. Different materials can be applied during the development of contact lenses and can be combined with natural inspired strategies of drug immobilization and release, providing successful tools for ocular drug delivery systems.
Porcar, Esteban; Montalt, Juan Carlos; España-Gregori, Enrique; Peris-Martínez, Cristina
2017-10-01
To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period was 1year. The best spectacle-corrected visual acuity was 20/32 with +8.00/-4.50×30° for the right eye (RE) and 20/25 with +7.75/-2.25×120° for the left eye (LE). After CScL fitting, visual acuity was improved to 20/20 and 20/16 for the RE and LE, respectively. The patient wore these contact lenses an average of 13h a day. The total high order aberrations decreased by approximately 79% in the RE (2.37-0.50μm) and 47% in the LE (1.04-0.55μm) after CScL fitting. Visual quality and wearing time were maintained after 1year wearing CScL. In addition, no adverse ocular effects were found during this period. The present case report describes how the patient had CScL fitted successfully for management of keratoconus with high hyperopia and astigmatism. They provided optimal visual quality, along with prolonged use times and no adverse effects to the cornea. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
González-Méijome, José M; López-Alemany, Antonio; Lira, Madalena; Almeida, José B; Oliveira, M Elisabete C D Real; Parafita, Manuel A
2007-01-01
The purpose of the present study was to develop mathematical relationships that allow obtaining equilibrium water content and refractive index of conventional and silicone hydrogel soft contact lenses from refractive index measures obtained with automated refractometry or equilibrium water content measures derived from manual refractometry, respectively. Twelve HEMA-based hydrogels of different hydration and four siloxane-based polymers were assayed. A manual refractometer and a digital refractometer were used. Polynomial models obtained from the sucrose curves of equilibrium water content against refractive index and vice-versa were used either considering the whole range of sucrose concentrations (16-100% equilibrium water content) or a range confined to the equilibrium water content of current soft contact lenses (approximately 20-80% equilibrium water content). Values of equilibrium water content measured with the Atago N-2E and those derived from the refractive index measurement with CLR 12-70 by the applications of sucrose-based models displayed a strong linear correlation (r2 = 0.978). The same correlations were obtained when the models are applied to obtain refractive index values from the Atago N-2E and compared with those (values) given by the CLR 12-70 (r2 = 0.978). No significantly different results are obtained between models derived from the whole range of the sucrose solution or the model limited to the normal range of soft contact lens hydration. Present results will have implications for future experimental and clinical research regarding normal hydration and dehydration experiments with hydrogel polymers, and particularly in the field of contact lenses. 2006 Wiley Periodicals, Inc.
Contact lens technology to 2020 and beyond: a review of recent patent literature.
Papas, Eric B
2017-09-01
Contact lenses have been a common means of vision correction for more than half a century. Recent developments raise the possibility that the next several years will see the range of applications in which they are used broaden considerably, with an associated expansion in both the number and type of individuals who consider them to be a valuable option. To describe this new landscape, a review of recent patent submissions covering the period 1 January 2014 to 1 February 2017 was undertaken. The results show that in the main, areas where contact lenses will be applied include drug delivery, visual augmentation and biosensing. © 2017 Optometry Australia.
Burnham, Geoffrey W; Cavanagh, H Dwight; Robertson, Danielle M
2012-01-01
To evaluate neutrophil-enhanced Pseudomonas aeruginosa (PA) biofilm formation on silicone hydrogel contact lenses and to determine the effect of epithelial biodebris on PA adherence in contact lens storage cases. A fully invasive PA corneal isolate stably conjugated to green fluorescent protein was used. Unworn lotrafilcon A contact lenses were incubated at various ratios of PA to polymorphonuclear neutrophil (PMN) for 24 hours at 37°C. Lens-associated PA was evaluated using laser scanning confocal microscopy and nonviable PA were visualized using propidium iodide. Viable bacteria were enumerated by colony-forming unit (CFU) analysis. For acute epithelial cell studies, PA viability was determined after coincubation with freeze-thaw epithelial cell lysates in 96-well polystyrene plates. Levels of residual cellular debris and bacterial viability were further assessed in used contact lens storage cases. Laser scanning confocal microscopy demonstrated that cotreatment with PMA-stimulated neutrophils increased PA adherence over 24 hours to lens surfaces with a striking alteration of PA architecture. Propidium iodide staining showed that the adherent bacteria consisted of a mixture of viable and nonviable PA; a PMN-associated increase in viable PA was confirmed by CFU (PA:PMN 0.1:1, P = 0.025; PA:PMN 1:1, P = 0.005). Acute epithelial cell debris studies revealed a significant increase in viable PA in 96-well plates in the presence of epithelial freeze-thaw lysates (PA:debris 1:1, P = 0.002; PA:debris 100:1, P = 0.002). Crystal violet staining of used lens storage cases revealed residual cellular debris at all time points, which was independent of microbial contamination; all lens cases used for periods of 9 months or more were uniformly associated with high levels of viable microorganisms. These results demonstrate that prolonged corneal inflammation with the presence of PMNs when confronted with simultaneous PA challenge in extended contact lens wear has the potential to stimulate biofilm formation on silicone hydrogel contact lenses. These findings further suggest that a persistent buildup of extracellular debris in lens storage cases may contribute to the heavy biofilms reported on these surfaces.
In vitro drug release and in vivo safety of vitamin E and cysteamine loaded contact lenses.
Dixon, Phillip; Fentzke, Richard C; Bhattacharya, Arnab; Konar, Aditya; Hazra, Sarbani; Chauhan, Anuj
2018-06-15
Cystinosis is an orphan disease caused by a genetic mutation that leads to deposition of cystine crystals in many organs including cornea. Ophthalmic manifestation of the disease can be treated with hourly instillation of cysteamine eye drops. The hourly eye drop instillation is tedious to the patients leading to poor compliance and additionally, significant degradation of the drug occurs within one week of opening the bottle, which further complicates this delivery approach. This paper focuses on designing a contact lens to treat the disease with improved efficacy compared to eye drops, and also exploring safety of the drug eluding contact lens in an animal model. Our goal is to design a lens that is safe and that can deliver a daily therapeutic dose of cysteamine to the cornea while retaining drug stability. We show that cysteamine diffuses out rapidly from all lenses due to its small size. Vitamin E incorporation increases the release duration of both ACUVUE ® OASYS ® and ACUVUE ® TruEye TM but the effect is more pronounced in TruEye TM likely due to the low solubility of vitamin E in the lens matrix and higher aspect ratio of the barriers. The barriers are not effective in hydrogel lenses, which along with the high aspect ratio in silicone hydrogels suggests that barriers could be forming at the interface of the silicone and hydrogel phases. The presence of vitamin E has an additional beneficial effect of reduction in the oxidation rates, likely due to a transport barrier between the oxygen diffusing through the silicone channels and drug located in the hydrogel phase. Based on this study, both Acuvue ® OASYS ® and ACUVUE ® TruEye TM can be loaded with vitamin E to design a cysteamine eluting contact lenses for effective therapy of cystinosis. The lenses must be worn for about 4-5 hr. each day, which is less than the typical duration of daily-wear. The vitamin E and cysteamine loaded lenses did not exhibit any toxicity in a rabbit model over a period of 7-days. Copyright © 2017 Elsevier B.V. All rights reserved.
The sterility of hospital-prepared Soffban bandages.
Wood, E V; Fenwick, H; Manning, M P; Mobbs, P
2005-11-01
An evaluation of the sterility of hospital-prepared Soffban bandages was undertaken. Discs of Bacillus stearothermophilus were inserted into the bandage rolls, prior to sterilization in "porous load" autoclaves. The discs were subsequently removed and placed in culture media, with growth of the organism indicating failure of sterilization. It was demonstrated that Soffban could not be sterilized reliably using standard hospital autoclave techniques.
Microfluidic wound bandage: localized oxygen modulation of collagen maturation.
Lo, Joe F; Brennan, Martin; Merchant, Zameer; Chen, Lin; Guo, Shujuan; Eddington, David T; DiPietro, Luisa A
2013-01-01
Restoring tissue oxygenation has the potential to improve poorly healing wounds with impaired microvasculature. Compared with more established wound therapy using hyperbaric oxygen chambers, topical oxygen therapy has lower cost and better patient comfort, although topical devices have provided inconsistent results. To provide controlled topical oxygen while minimizing moisture loss, a major issue for topical oxygen, we have devised a novel wound bandage based on microfluidic diffusion delivery of oxygen. In addition to modulating oxygen from 0 to 100% in 60 seconds rise time, the microfluidic oxygen bandage provides a conformal seal around the wound. When 100% oxygen is delivered, it penetrates wound tissues as measured in agar phantom and in vivo wounds. Using this microfluidic bandage, we applied the oxygen modulation to 8 mm excisional wounds prepared on diabetic mice. Treatment with the microfluidic bandage demonstrated improved collagen maturity in the wound bed, although only marginal differences were observed in total collagen, microvasculature, and external closure rates. Our results show that proper topical oxygen can improve wound parameters underneath the surface. Because of the ease of fabrication, the oxygen bandage represents an economical yet practical method for oxygen wound research. © 2013 by the Wound Healing Society.
A wearable stimulation bandage for electrotherapy studies in a rat ischemic wound model.
Howe, Daniel S; Dunning, Jeremy L; Henzel, Mary K; Graebert, Jennifer K; Bogie, Kath M
2011-01-01
The clinical efficacy of electro-therapy in the treatment of chronic wounds is currently debated, and a in-vivo evaluation of stimulation parameters will provide the statistical evidence needed to direct clinical guidelines. A low-cost, wearable electrical stimulation bandage has been developed for use with an established rat ischemic wound model. The bandage consists of a user-programmable stimulator PCB and a plastic bandage with two hydrogel electrodes. The battery-powered bandage may be used for up to seven days between dressing changes, and the stimulator may be reused. The microcontroller-based stimulator uses a boost converter circuit to generate pulses up to 90 V from a 3 V coin cell battery. Consistent operation of the boost converter over the wide input and output voltage ranges is achieved using voltage feedforward and soft-start techniques implemented in firmware. The bandages are laser-cut to shape, and electrical traces are applied using stencils and conductive nickel paint. Both the PCB and electrical traces are encapsulated to protect the animal. The device has been successfully demonstrated using the rat ischemic wound model for a period of seven days, and clinical experiments are ongoing.
Contact Lens Anterior Surface pH
1991-02-01
greenhouse effect and contact lenses, in Trans- 4. Nom MS: Tear fluid pH in normals, contact lens wearers, actions of the British Contact Lens...Invest 3. Fullard R), Carney LG: Diurnal variation in human tear en- Op/hdanmol Vis Sci 1978;17:810-813. ymes. Exp Eye Res 1984;38:15-26. 20. Efron N: The
O'Brien, C; Charman, W N
2006-05-01
After a preliminary investigation of the effects of tool feed rate and spindle speed on the surface roughness of unhydrated, lathe-cut polymacon surfaces, a laboratory and clinical comparison was made between lenses with identical parameters except that the lathe-cut posterior surface was left unpolished in the "test" lenses and was polished in the "control" lenses. The lenses had moulded anterior surfaces. Laboratory comparisons included surface roughness, lens power and its uniformity across the surface. Double-blind clinical trials over 4-hour (27 subjects) and 1-month (10 subjects) periods, involved one eye of each subject wearing a "test" lens and the other, a "control" lens. No clinically significant differences were found between the results for the test and control lenses. It is concluded that today's lathing technology makes a final polishing stage unnecessary.
Failure of chemotherapy in the first reported cases of Acanthamoeba keratitis in Pakistan
Siddiqui, Ruqaiyyah; Chaudhry, Tanveer; Lakhundi, Sahreena; Ahmad, Khabir; Khan, Naveed Ahmed
2014-01-01
Acanthamoeba keratitis is a painful and progressive infection of the cornea that can result in loss of vision. Here, for the first time in Pakistan, we report two cases of Acanthamoeba keratitis. The first patient was a 37-year-old female who presented with severe itching, redness, pain, along with loss of vision. The patient was a regular soft contact lens wearer. The second patient was a 25-year-old female who had been using soft contact lenses for the past two years. She presented with a burning sensation and extreme pain, along with loss of vision. Both patients were treated for a possible microbial keratitis with topical moxifloxacin hydrochloride drops, vancomycin drops, propamidine isethionate ointment, amphotericin B drops, and amikacin drops. However, the response was inadequate and both patients were referred for corneal transplant. Acanthamoeba castellanii was isolated by placing contact lenses and contact lens cases on non-nutrient agar plates containing a lawn of non-invasive Escherichia coli K-12 HB101 bacteria. The polymerase chain reaction (PCR) using genus-specific probes confirmed the identity of Acanthamoeba spp., whereas the morphological characteristics of trophozoites and cysts were suggestive of A. castellanii in both cases. With growing use of contact lenses for vision correction/cosmetic use coupled with sub-standard lens care in this region and the possibility of non-contact lens-associated Acanthamoeba keratitis, a need for increased awareness of this sight-threatening infection is discussed further. PMID:24548160
Design and some practical applications of ultrasonic transducers with axicon lenses
NASA Astrophysics Data System (ADS)
Katchadjian, P.; Desimone, C.; Garcia, A.
2013-01-01
In this paper the applications, detailed in previous papers, referred to ultrasonic transducers with the addition of axicon lenses are extended. Axicon lenses, both contact and immersion, for normal and angular incidence were manufactured, in order to study defectology in welds and other components. For immersion transducers, as had already been made for contact transducers, signal amplitude in function of the depth of the reflector and transverse acoustic pressure at the focus were measured. For this purpose a small metallic sphere submerged in different fluids was used. Several practical applications are shown where it is possible to exploit the advantages that these transducers offer: high resolution measurements for corrosion, laminations and thickness reduction. Discrimination between a weld root and a defect very close to it, etc. Measurements in anisotropic materials (composites) in order to achieve an SNR improvement.
Compliance factors associated with contact lens-related dry eye.
Ramamoorthy, Padmapriya; Nichols, Jason Jay
2014-01-01
To determine if compliance factors are associated with contact lens-related dry eye (CLDE). The data were derived from subject responses to a compliance survey administered in a cross-sectional study including 100 healthy, daily (nonovernight), experienced soft contact lens wearers (50 normal and 50 with CLDE). Classification into normal or CLDE groups was based on Contact Lens Dry Eye Questionnaire scores, tear breakup time, and 2 hours difference between total and comfortable daily lens wear hours. The compliance survey queried aspects of lens care, rub and rinse practices, lens and lens case replacement frequency, solution replacement, and sleeping with lenses. Statistical analysis of the data was performed using unpaired T tests, χ, and Fisher exact tests as applicable. The average age of all subjects was 24.8±4.4 years, and 60% were women. Overall compliance rates were low for several variables including recommended replacement of contact lenses (53%), rub and rinse practices (69% and 45%, respectively), care solution topping-off (80%), and washing hands before handling lenses (48%). However, almost no compliance factors were associated with CLDE status, with the exception of perceived ease or difficulty with lens care, which was rated as more difficult by the CLDE group (P=0.004). Overall compliance rates with contact lens care practices are very low, highlighting the need for more effective methods of patient education regarding contact lens care and compliance. However, almost no compliance factors were found to be associated with CLDE. Factors other than compliance likely play a bigger role in CLDE.
Khan-Lim, Doreen; Craig, Jennifer P; McGhee, Charles N J
2002-05-01
To determine the relative importance of patients' motives for having laser in situ keratomileusis (LASIK) for myopia. The Corneal Diseases and Excimer Laser Research Unit, University of Dundee, Ninewells Hospital and Medical School, Dundee, Scotland. Twenty-one cards printed with potential reasons for having LASIK and 3 blank cards for respondents to include additional motives were posted to 71 patients who had myopic LASIK. The cards were ranked by each respondent in order of personal importance and returned for analysis. The response rate was 77.5%. The mean age of the 19 male and 37 female respondents was 41.7 years +/- 9.3 (SD) and the mean preoperative spherical equivalent, -9.26 +/- 4.58 diopters. The primary reasons for seeking treatment (percentage of respondents ranking topic within the top 5) were improvement of unaided social vision (69.1%), intolerance to spectacles/contact lenses (65.5%), and freedom from spectacles/contact lenses (61.8%). Almost 70% of respondents ranked 1 of these reasons as the most important. General inconvenience of spectacles/contact lenses and the desire to pursue sports and leisure activities also ranked high (52.7% and 36.4%, respectively). Consistent with previous work, better unaided vision, combined with the inconvenience of or intolerance to spectacles or contact lenses, provided the main incentives to have LASIK for myopia, while improved cosmesis was relatively unimportant (29.1%). The results of this study will allow the design of satisfaction questionnaires that are better directed toward establishing satisfaction of specific, relevant functional and psychological aspects of refractive surgery that are important to patients.
Davies, C E; Woolfrey, G; Hogg, N; Dyer, J; Cooper, A; Waldron, J; Bulbulia, R; Whyman, M R; Poskitt, K R
2015-12-01
Slough in chronic venous leg ulcers may be associated with delayed healing. The purpose of this study was to assess larval debridement in chronic venous leg ulcers and to assess subsequent effect on healing. All patients with chronic leg ulcers presenting to the leg ulcer service were evaluated for the study. Exclusion criteria were: ankle brachial pressure indices <0.85 or >1.25, no venous reflux on duplex and <20% of ulcer surface covered with slough. Participants were randomly allocated to either 4-layer compression bandaging alone or 4-layer compression bandaging + larvae. Surface areas of ulcer and slough were assessed on day 4; 4-layer compression bandaging was then continued and ulcer size was measured every 2 weeks for up to 12 weeks. A total of 601 patients with chronic leg ulcers were screened between November 2008 and July 2012. Of these, 20 were randomised to 4-layer compression bandaging and 20 to 4-layer compression bandaging + larvae. Median (range) ulcer size was 10.8 (3-21.3) cm(2) and 8.1 (4.3-13.5) cm(2) in the 4-layer compression bandaging and 4-layer compression bandaging + larvae groups, respectively (Mann-Whitney U test, P = 0.184). On day 4, median reduction in slough area was 3.7 cm(2) in the 4-layer compression bandaging group (P < 0.05) and 4.2 cm(2) (P < 0.001) in the 4-layer compression bandaging + larvae group. Median percentage area reduction of slough was 50% in the 4-layer compression bandaging group and 84% in the 4-layer compression bandaging + larvae group (Mann-Whitney U test, P < 0.05). The 12-week healing rate was 73% and 68% in the 4-layer compression bandaging and 4-layer compression bandaging + larvae groups, respectively (Kaplan-Meier analysis, P = 0.664). Larval debridement therapy improves wound debridement in chronic venous leg ulcers treated with multilayer compression bandages. However, no subsequent improvement in ulcer healing was demonstrated. © The Author(s) 2014.
Fluctuation in visual acuity during soft toric contact lens wear.
Chamberlain, Paul; Morgan, Philip B; Moody, Kurt J; Maldonado-Codina, Carole
2011-04-01
To quantify changes in visual acuity (VA) with soft toric contact lenses as a result of lens movement and/or rotational instability caused by versional eye movements. A novel chart for vision assessment at near (40 cm) for soft toric contact lenses (VANT chart),consisting of a central, color-coded logMAR panel and eight peripheral letter targets set on a white background measuring 60 × 40 cm was constructed. In the developmental phase of the work, 10 subjects (20 eyes) wore 2 toric lenses in random order, and the impact of rapid and delayed eye versions in 8 directions of gaze on VANT acuity was investigated. In phase 2, 35 subjects (68 eyes) wore 4 toric lenses in random order, and a streamlined clinical protocol using the VANT chart was implemented. Standard assessments of toric lens fit and distance VA were also performed. Testing in the first phase showed no difference for change in VA for rapid vs. delayed version movements, (p = 0.17) but acuity reduction was greater for diagonal compared with horizontal/vertical versions (p = 0.06). As such, testing in phase 2 proceeded using rapid, diagonal versions only. In this second phase, there were differences for low-contrast distance VA measures between lens types (p = 0.02) and for both VANT baseline acuity (p = 0.03) and postversion acuity (p = 0.04), but no differences were found between lenses for magnitude of vision loss (p = 0.91), which was about one line. No relationship was established between the magnitude of vision loss and measured rotational stability (p = 0.75). This work has demonstrated that conventional approaches to measuring VA do not fully replicate the "real world" experience of soft toric lens wearers. The VANT chart has shown that VA is reduced immediately after versional eye movements and suggests that more dynamic methods of assessing visual performance should be considered for soft toric contact lens wearers, especially given the apparent inability of lens stability measurements to predict visual performance.
Opdahl, Aric; Kim, Seong H; Koffas, Telly S; Marmo, Chris; Somorjai, Gabor A
2003-10-01
The surface mechanical properties of poly(hydroxyethyl)methacrylate (pHEMA)-based contact lenses were monitored as a function of humidity by atomic force microscopy (AFM). Surface viscoelastic and adhesion values were extracted from AFM force versus distance interaction curves and were found to be strongly dependent on the bulk water content of the lens and on the relative humidity. At low relative humidity, 40-50%, the dehydration rate from the surface is faster than the hydration rate from the bulk, leading to a rigid surface region that has mechanical properties similar to those measured on totally dehydrated lenses. At relative humidity values > 60%, the dehydration rate from the lens surface rapidly decreases, leading to higher surface water content and a softer surface region. The results indicate that, in an ocular environment, although the bulk of the pHEMA contact lens is hydrated, the surface region may be in a transition between a dehydrated glassy state and a hydrated rubbery state. Copyright 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 350-356, 2003
Effect of three months of soft contact lens wear on conjunctival cytology.
Sapkota, Kishor; Franco, Sandra; Sampaio, Paula; Lira, Madalena
2016-07-01
The purpose of this study was to investigate the effect of three months of soft contact lens wear on conjunctival goblet cell density and epithelial cell morphology. This was a longitudinal clinical trial. Conjunctival impression cytology was performed on the superior palpebral conjunctiva in fifty-four eyes of twenty-seven neophyte contact lens wearers before and after three months of contact lens wear. Goblet cell density was determined by optical microscopy and epithelial cell morphology was classified according to the Tseng classification. Changes in goblet cell density as well as epithelial cell grading were determined. The effects of lens material and wearing modality on cytological changes were also investigated. Goblet cell density reduced significantly by 85 ± 151 cells/mm(2) (p < 0.001) after three months of contact lens wear. Reduction in goblet cell density was associated with lens materials; it was higher in conventional hydrogel lenses in comparison to silicone-hydrogel lenses (p = 0.008). The highest reduction in goblet cell density was found with Nelfilcon A lens wear (p = 0.002) and the lowest with Comfilcon A lens wear (p = 0.414). There was no statistically significant difference in grading of epithelial metaplasia before and after three months of contact lens wear (p = 0.075). Age was not correlated with the reduction in goblet cell density (r = -0.196, p = 0.160) but it was associated with the change in epithelial cell morphology (p = 0.036). Three months of soft contact lens wear statistically significantly reduced goblet cell density; however, no significant changes were found in the grading of epithelial metaplasia. Contact lenses with lower oxygen permeability, higher Young modulus and higher thickness highly affected the conjunctival cytology. © 2016 Optometry Australia.
Ashby, Rebecca L; Gabe, Rhian; Ali, Shehzad; Adderley, Una; Bland, J Martin; Cullum, Nicky A; Dumville, Jo C; Iglesias, Cynthia P; Kang'ombe, Arthur R; Soares, Marta O; Stubbs, Nikki C; Torgerson, David J
2014-03-08
Drawbacks exist with the standard treatment (four-layer compression bandages) for venous leg ulcers. We have therefore compared the clinical effectiveness and cost-effectiveness of two-layer compression hosiery with the four-layer bandage for the treatment of such ulcers. We undertook this pragmatic, open, randomised controlled trial with two parallel groups in 34 centres in England and Northern Ireland. The centres were community nurse teams or services, family doctor practices, leg ulcer clinics, tissue viability clinics or services, and wound clinics. Participants were aged 18 years or older with a venous leg ulcer and an ankle brachial pressure index of at least 0·8, and were tolerant of high compression. We randomly allocated participants (1:1) to receive two-layer compression hosiery or a four-layer bandage, using a remote randomisation service and prevalidated computer randomisation program. Participants were stratified by ulcer duration and ulcer area with permuted blocks (block sizes four and six). The primary endpoint was time to ulcer healing, with a maximum follow-up of 12 months. Although participants and health-care providers were not masked to treatment allocation, the primary endpoint was measured by masked assessment of photographs. Primary analysis was intention to treat with Cox regression, with adjustment for ulcer area, ulcer duration, physical mobility, and centre. This trial is registered with the ISRCTN register, number ISRCTN49373072. We randomly allocated 457 participants to the two treatment groups: 230 to two-layer hosiery and 227 to the four-layer bandage, of whom 453 (230 hosiery and 223 bandage) contributed data for analysis. Median time to ulcer healing was 99 days (95% CI 84-126) in the hosiery group and 98 days (85-112) in the bandage group, and the proportion of ulcers healing was much the same in the two groups (70·9% hosiery and 70·4% bandage). More hosiery participants changed their allocated treatment (38·3% hosiery vs 27·0% bandage; p=0·02). 300 participants had 895 adverse events, of which 85 (9·5%) were classed as serious but unrelated to trial treatment. Two-layer compression hosiery is a viable alternative to the four-layer bandage-it is equally as effective at healing venous leg ulcers. However, a higher rate of treatment changes in participants in the hosiery group than in the bandage group suggests that hosiery might not be suitable for all patients. NIHR Health Technology Assessment programme (07/60/26). Copyright © 2014 Elsevier Ltd. All rights reserved.
Surface wettability enhancement of silicone hydrogel lenses by processing with polar plastic molds.
Lai, Y C; Friends, G D
1997-06-05
In the quest for hydrogel contact lenses with improved extended wear capability, the use of siloxane moieties in the lens materials was investigated. However, the introduction of hydrophobic siloxane groups gave rise to wettability and lipidlike deposit problems. It was found that when polysiloxane-based compositions for hydrogels were processed with polar plastic molds, such as those fabricated from an acrylonitrile-based polymer, the hydrogel lenses fabricated were wettable, with minimized lipidlike deposits. These findings were supported by the wettability of silicone hydrogel films, silicon, and nitrogen element contents near lens surfaces, as well as the results from clinical assessment of silicone hydrogel lenses.
Heynen, Miriam; Luensmann, Doerte; Jones, Lyndon
2012-01-01
Purpose To determine the impact of incubation solution composition on protein deposition to silicone hydrogel (SH) contact lenses using a simplistic and a complex model of the tear film. Methods Three SH materials – senofilcon A (SA), lotrafilcon B (LB), and balafilcon A (BA) – were incubated in two different solutions; Solution A was a simplistic augmented buffered saline solution containing a single protein, whereas Solution B was a complex artificial tear solution (ATS), containing the augmented buffered saline solution in addition to proteins, lipids, and mucins (pH=7.4). The proteins of interest (lysozyme, lactoferrin, albumin) were radiolabeled with Iodine-125 (2% protein of interest) and the accumulation of the conjugated protein to the lens materials was determined after 1, 7, 14, and 28 days of incubation. Protein deposition was measured using a gamma counter and the raw data were translated into absolute amounts (µg/lens) via extrapolation from standards. Results After 28 days, lysozyme uptake was significantly lower on BA lenses when incubated in Solution A (33.7 μg) compared to Solution B (56.2 μg), p<0.001. SA lenses deposited similar amounts of lysozyme when incubated in either Solution A (2.6 μg) or Solution B (4.1 μg), p>0.05. LB lenses also deposited similar amounts of lysozyme for both solutions (Solution A: 5.0 μg, Solution B: 4.7 μg, p>0.05). After 28 days, BA lenses accumulated approximately twice the amount of lactoferrin than the other lens materials, with 30.3 μg depositing when exposed to Solution A and 22.0 μg with Solution B. The difference between the two solutions was statistically significant (p<0.001). LB materials deposited significantly greater amounts of lactoferrin when incubated in Solution A (16.6 μg) compared to Solution B (10.3 μg), p<0.001. Similar amounts of lactoferrin were accumulated onto SA lenses regardless of incubation solution composition (Solution A: 8.2 μg, Solution B: 11.2 μg, p>0.05). After 28 days, albumin deposition onto BA lenses was significantly greater when lenses were incubated in Solution B (1.7 μg) compared to Solution A (0.9 μg), p<0.001. Similar amounts of albumin were deposited on SA lenses when incubated in either solution (0.6 μg versus 0.7 μg, p>0.05). LB lenses incubated in Solution A deposited more albumin compared to Solution B (0.9 μg versus 0.6 μg), p=0.003. Discussion Protein deposition onto SH materials varied when contact lenses were incubated in either a complex ATS compared to a single protein solution. More lysozyme accumulated onto BA lenses incubated in a complex analog of the human tear film, whereas lactoferrin deposited onto SA lenses independent of incubation solution composition. To better mimic the ex vivo environment, future studies should use more appropriate analogs of the tear film. PMID:22355245
A medical bandage in an Italian Renaissance mummy (Naples, XVI century).
Giuffra, Valentina; Marinozzi, Silvia; Vultaggio, Claudia; Fornaciari, Gino
2008-01-01
A dressing was observed on the left arm of the mummy of Mary of Aragon (1503-1568), under her precious Renaissance clothes. It consisted of a true medical bandage, covering a large syphilitic cutaneous ulcer, with a sulphur-embedded wad still in situ. The bandage has a very peculiar shape, rather different from the usual dressings described in the contemporary medical texts: a central rectangular pad, used as compressing appliance, is provided with a sort of pocket containing ivy leaves. The function of the dressing was not only to cover and protect the ulcer, but also to apply a plant drug. This is the first case of ancient medical bandage studied directly on a mummified body.
Effects of Soft Contact Lenses on Contrast Sensitivity
1983-04-01
Problem ............... .......... 7 Subjects .. ............... ............... 9 *Material and Methods .. ............... ......... 14 Treatment of...abil- ity to achieve visual acuity comparable to that with their spectacle lenses, these patients frequently complain that their new vision is "not...available through Cadwell Laboratories) and the Arden Photographic Plates (available from American Optical Co.). In light of these new capabilities and
Cowell, B A; Willcox, M D; Schneider, R P
1998-06-01
Adhesion of bacteria to hydrogel lenses is thought to be an initial step of ocular colonization allowing evasion of normal host defences. The salt concentration of media is an important parameter controlling microbial adhesion. Salinity varies from 0.97% NaCl equivalents in the open eye to 0.89% in the closed eye state. In this study, the effect of sodium chloride in the concentration range of 0.8-1.0% (w/v) NaCl on adhesion of ocular bacteria to soft contact lenses was investigated using a static adhesion assay. Pseudomonas aeruginosa was found to adhere to lenses in significantly greater amounts than Serratia marcescens, Flavobacterium meningosepticum, Stenotrophomonas maltophilia and Staphylococcus intermedius. Increasing NaCl from 0.8% to 1.0% (w/v) increased adhesion of all bacteria tested. This adhesion was strong since the organisms could not be removed by washing in low ionic buffer. Adhesion of these organisms did not correlate with their cell surface properties as determined by bacterial adhesion to hydrocarbons (BATH) and retention on sepharose columns.
Visual acuity estimation from simulated images
NASA Astrophysics Data System (ADS)
Duncan, William J.
Simulated images can provide insight into the performance of optical systems, especially those with complicated features. Many modern solutions for presbyopia and cataracts feature sophisticated power geometries or diffractive elements. Some intraocular lenses (IOLs) arrive at multifocality through the use of a diffractive surface and multifocal contact lenses have a radially varying power profile. These type of elements induce simultaneous vision as well as affecting vision much differently than a monofocal ophthalmic appliance. With myriad multifocal ophthalmics available on the market it is difficult to compare or assess performance in ways that effect wearers of such appliances. Here we present software and algorithmic metrics that can be used to qualitatively and quantitatively compare ophthalmic element performance, with specific examples of bifocal intraocular lenses (IOLs) and multifocal contact lenses. We anticipate this study, methods, and results to serve as a starting point for more complex models of vision and visual acuity in a setting where modeling is advantageous. Generating simulated images of real- scene scenarios is useful for patients in assessing vision quality with a certain appliance. Visual acuity estimation can serve as an important tool for manufacturing and design of ophthalmic appliances.
Modeling Corneal Oxygen with Scleral Gas Permeable Lens Wear.
Compañ, Vicente; Aguilella-Arzo, Marcel; Edrington, Timothy B; Weissman, Barry A
2016-11-01
The main goal of this current work is to use an updated calculation paradigm, and updated boundary conditions, to provide theoretical guidelines to assist the clinician whose goal is to improve his or her scleral gas permeable (GP) contact lens wearing patients' anterior corneal oxygen supply. Our model uses a variable value of corneal oxygen consumption developed through Monod equations that disallows negative oxygen tensions within the stroma to predict oxygen tension at the anterior corneal surface of scleral GP contact lens wearing eyes, and to describe oxygen tension and flux profiles, for various boundary conditions, through the lens, tears, and cornea. We use several updated tissue and boundary parameters in our model. Tear exchange with GP scleral lenses is considered nonexistent in this model. The majority of current scleral GP contact lenses should produce some levels of corneal hypoxia under open eye conditions. Only lenses producing the thinnest of tear vaults should result in anterior corneal surface oxygen tensions greater than a presumed critical oxygen tension of 100 mmHg. We also find that corneal oxygen tension and flux are each more sensitive to modification in tear vault than to changes in lens oxygen permeability, within the ranges of current clinical manipulation. Our study suggests that clinicians would be prudent to prescribe scleral GP lenses manufactured from higher oxygen permeability materials and especially to fit without excessive corneal clearance.
Yuksel Elgin, Cansu; Iskeleli, Guzin; Aydin, Ovgu
2018-06-01
To investigate changes in tear and ocular surface of patients with keratoconus using rigid gas permeable contact lenses (RGPCL) and compare them against keratoconus patients who were not using lenses as well as a control group of healthy subjects. 24 keratoconus patients using RGPCL (Group 1) 22 patients who were not using lenses (Group 3) and 21 healthy subjects (Group 3) were included in the study. Subjective complaints about the subjects' eyes have been investigated using the ocular-surface disease index (OSDI). After the control of best-corrected visual acuity, anterior chamber and fundus examinations were performed. Schirmer (p-value=0.01) and tear break up mean comparison tests (p-value=0.002) revealed significant differences across different groups but tear osmolarity analysis did not (p-value >0.05). Oxford and OSDI scores were compatible with Schirmer and tear break up test comparisons. (for both p-value=0.001) Moreover, no statistical differences were seen in impression cytology measures between groups. (p-value >0.05) CONCLUSIONS: The erosion in the tear film stability is in line with the erosion in the ocular surface epithelium. Taking into account the statistical indifference between the impression cytology measures across groups, the break up time differences may be attributed to the collagen destruction in tear. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Peripheral Optics with Bifocal Soft and Corneal Reshaping Contact Lenses
Ticak, Anita; Walline, Jeffrey J.
2012-01-01
Purpose To determine whether bifocal soft contact lenses with a distance center design provide myopic defocus to the peripheral retina similar to corneal reshaping contact lenses. Methods Myopic subjects underwent five cycloplegic autorefraction readings centrally and at 10, 20, and 30 degrees temporally, nasally, superiorly, inferiorly while wearing a Proclear Multifocal “D” contact lens with a +2.00 D add (CooperVision, Fairport, NY) and after wearing a Corneal Refractive Therapy (Paragon Vision Sciences, Mesa, AZ) contact lens for two weeks Results Fourteen subjects completed the study. Nine (64%) were female, and 12 (86%) were Caucasian. The average (± standard deviation) spherical equivalent non-cycloplegic manifest refraction for the right eye was −2.84 ± 1.29 D. The average logMAR best-corrected, binocular high contrast visual acuity was −0.17 ± 0.15 while wearing the bifocal soft contact lens, and −0.09 ± 0.16 following corneal reshaping contact lens wear (ANOVA, p = 0.27). The orthokeratology contact lens yielded a more myopic peripheral optical profile than the soft bifocal contact lens at 20 and 30 degrees eccentricity (except inferior at 20 degrees); the two modalities were similar at 10 degrees eccentricity. Conclusions Our data suggest that the two modalities are dissimilar despite the statistical similarities. The corneal reshaping contact lens shows an increase in relative peripheral myopic refraction, a pattern achieved by other studies, but the bifocal lens does not exhibit such a pattern. The low statistical power of the study could be a reason for a lack of providing statistical difference in other positions of gaze, but the graphical representation of the data shows a marked difference in peripheral optical profile between the two modalities. More sophisticated methods of measuring the peripheral optical profile may be necessary to accurately compare the two modalities and to determine the true optical effect of the bifocal soft contact lens on the peripheral retina. PMID:23222924
Ethylene oxide-block-butylene oxide copolymer uptake by silicone hydrogel contact lens materials
NASA Astrophysics Data System (ADS)
Huo, Yuchen; Ketelson, Howard; Perry, Scott S.
2013-05-01
Four major types of silicone hydrogel contact lens material have been investigated following treatments in aqueous solutions containing poly(ethylene oxide) and poly(butylenes oxide) block copolymer (EO-BO). The extent of lens surface modification by EO-BO and the degree of bulk uptake were studied using X-ray photoelectron spectroscopy (XPS) and ultra-performance liquid chromatography (UPLC), respectively. The experimental results suggest that different interaction models exist for the lenses, highlighting the influence of both surface and bulk composition, which greatly differs between the lenses examined. Specifically, lenses with hydrophilic surface treatments, i.e., PureVision® (balafilcon A) and O2OPTIX (lotrafilcon B), demonstrated strong evidence of preferential surface adsorption within the near-surface region. In comparison, surface adsorption on ACUVUE® Oasys® (senofilcon A) and Biofinity® (comfilcon A) was limited. As for bulk absorption, the amount of EO-BO uptake was the greatest for balafilcon A and comfilcon A, and least for lotrafilcon B. These findings confirm the presence of molecular concentration gradients within the silicone hydrogel lenses following exposure to EO-BO solutions, with the nature of such concentration gradients found to be lens-specific. Together, the results suggest opportunities for compositional modifications of lenses for improved performance via solution treatments containing surface-active agents.
Compliance and hygiene behaviour among soft contact lens wearers in the Maldives.
Gyawali, Rajendra; Nestha Mohamed, Fathimath; Bist, Jeewanand; Kandel, Himal; Marasini, Sanjay; Khadka, Jyoti
2014-01-01
Significant levels of non-compliance and poor hygiene among contact lens wearers have been reported previously from different parts of the world. This survey aimed at identifying the scope of hygiene and non-compliant behaviour of soft contact lens wearers in the Maldives. Established soft lens wearers attending two eye clinics in Male' city, were interviewed in office or via telephone. A set of interviewer-administered questions was used to access the subjective response on compliance and hygiene behaviour (hand and lens case hygiene, water exposure, adherence to lens replacement schedule, dozing and overnight wear, awareness of aftercare visits and reuse of disinfecting solution). Participants were also asked to rate themselves as a contact lens user based on their perceived compliance and hygiene practices. Out of 107 participants, 79 (74.8 per cent) were interviewed in the office and the rest via telephone. The majority of lens wearers were female, office workers and students, with a mean age of 20.64 ± 4.4 years. Mean duration of lens wear was 28.04 ± 8.36 months. Most of them were using spherical lenses (86.9 per cent) on a daily wear basis (96.3 per cent). Major reported forms of non-compliance were poor hand hygiene (60.7 per cent), lack of aftercare awareness (39.3 per cent), water exposure (35.5 per cent) and over-use of lenses (24.3 per cent). While females were more likely to overuse their lenses than males (p < 0.005), other socio-demographic factors were not associated with reported non-compliance. Although around 90 per cent of the participants considered themselves average or good contact lens wearers, most exhibited some form of non-compliant and poor hygienic behaviour. A significant number of Maldivian contact lens wearers exhibited poor levels of hygiene and compliance with contact lenses and lens care systems. An effective educational reinforcement strategy needs to be developed to modify lens wearers' non-compliance. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
de Carvalho, Isabela Feitosa; Leme, Gianluca Loyolla Montanari; Scheicher, Marcos Eduardo
2018-01-01
The aim of the study was to investigate the effect of balance training with Nintendo Wii technology, with and without the use of additional sensory information (subpatellar bandage), in the functional mobility and gait speed of elderly female fallers. Twenty elderly women were divided into two groups: group I: trained with the use of the Nintendo Wii; group II: trained using the Nintendo Wii and the addition of sensory information (subpatellar bandage). The functional mobility was assessed with the Timed up and Go test (TUG) and gait speed with the 10 m test. The tests were carried out with and without the use of the subpatellar bandage. The training was carried out within sessions of 30 minutes, twice a week, using three different games ( Penguin Slide , Table Tilt , and Tightrope ). There was an increase in the gait speed and a decrease in the TUG time in both groups, independently of the sensory condition used ( p < 0.05). In the short term, the subpatellar bandage improved the TUG time ( p < 0.05) and the gait speed ( p < 0.01). The training for postural balance with virtual reality was effective for improving functional mobility and gait speed of elderly female fallers. The subpatellar bandage did not maximize the effect of training.
Power profiles and short-term visual performance of soft contact lenses.
Papas, Eric; Dahms, Anne; Carnt, Nicole; Tahhan, Nina; Ehrmann, Klaus
2009-04-01
To investigate the manner in which contemporary soft contact lenses differ in the distribution of optical power within their optic zones and establish if these variations affect the vision of wearers or the prescribing procedure for back vertex power (BVP). By using a Visionix VC 2001 contact lens power analyzer, power profiles were measured across the optic zones of the following contemporary contact lenses ACUVUE 2, ACUVUE ADVANCE, O2OPTIX, NIGHT & DAY and PureVision. Single BVP measures were obtained using a Nikon projection lensometer. Visual performance was assessed in 28 masked subjects who wore each lens type in random order. Measurements taken were high and low contrast visual acuity in normal illumination (250 Cd/m), high contrast acuity in reduced illumination (5 Cd/m), subjective visual quality using a numerical rating scale, and visual satisfaction rating using a Likert scale. Marked differences in the distribution of optical power across the optic zone were evident among the lens types. No significant differences were found for any of the visual performance variables (p > 0.05, analysis of variance with repeated measures and Friedman test). Variations in power profile between contemporary soft lens types exist but do not, in general, result in measurable visual performance differences in the short term, nor do they substantially influence the BVP required for optimal correction.
A novel phosphorylcholine-coated contact lens for extended wear use.
Court, J L; Redman, R P; Wang, J H; Leppard, S W; Obyrne, V J; Small, S A; Lewis, A L; Jones, S A; Stratford, P W
2001-12-01
The preparation and characterisation of a new phosphorylcholine (PC)-coated silicone hydrogel contact lens for use in extended wear is described. The Michael-type addition of amines to acrylates forms the basis of the synthesis of a novel silicone-based macromer with hydrophilic functionality. It is demonstrated that this macromer can be combined with other silicone-based monomers, hydrophilic monomers and crosslinker to produce a contact lenses formulation. Examples of lenses with water contents of 33% and 46% are illustrated and their properties compared to other commercially available lenses. Materials with comparatively low modulus (<0.3 MPa) and adequate tear strength (>2-4MPa) with excellent elongation to break (>200%) can be obtained using this technology. In addition to the mechanical aspects. both the oxygen and solute permeabilities of the material can be controlled by the hydrophilic: hydrophobic monomer balance in the formulation. to obtain materials with attributes suitable for extended wear use. The PC coating is achieved by means of an in-mould coating (IMC) technique that produces a uniform and stable surface as determined by staining and XPS. The coating imparts both improved lens wettability (advancing contact angle of approximately 50 with virtually no hysteresis) and lower protein adsorption relative to the uncoated lens.
The production and measurement of sub-bandage pressure: Laplace's Law revisited.
Thomas, S
2014-05-01
The present study was undertaken to demonstrate that the pressures produced by multiple layers of compression bandages applied to artificial limbs of known circumference with predetermined levels of tension can be predicted accurately using the modified Laplace equation. Up to four layers of different bandage types were applied in a carefully controlled fashion to cylinders of known circumference, with tensions ranging from around 200-2000 grams/10cm width. The pressures generated were measured using pneumatic pressure sensors previously shown to possess the required degree of accuracy for this type of experimental system. Good correlation was observed between the mean and standard deviation of each pair of experimental and calculated pressure values for all combinations of bandage type, application tension and cylinder circumference. Over the clinically relevant range of pressures, the difference between data sets was generally less than 1.0mmHg. The results of this experimental study unequivocally prove that provided accurate values for all the relevant variables are known, it is possible to predict the pressure that will be developed by a compression bandage on a limb of known size. However, it is important to recognise that other factors such as the elastomeric properties of the fabric will have a major effect upon the ability of a bandage system to sustain initial compression values. Furthermore, the variation in radius of curvature around a limb will mean that point pressures readings recorded at individual locations around the circumference may vary dramatically from the average value predicted by the modified Laplace equation, calling into question the value of sub-bandage pressure measuring devices for this application.
German, Benjamin T; Hack, Jason B; Brewer, Kori; Meggs, William J
2005-06-01
Pressure-immobilization bandages are used in countries where neurotoxic snake envenomations are common. They impede lymphatic egress from the bite site and delay systemic venom toxicity. The effectiveness of these devices has not been evaluated in coral snake envenomations. We investigated the efficacy of pressure-immobilization bandages in delaying the onset of systemic toxicity in a porcine model of coral snake envenomation. A randomized controlled trial of pressure-immobilization bandages was conducted in a university animal care center. Subjects were 12 anesthetized, spontaneously breathing pigs, ranging from 9.1 to 11.4 kg. After injection with 10 mg of Micrurus fulvius fulvius venom in the subcutaneous tissue of the distal foreleg, subjects were randomized to receive no treatment or application of a pressure-immobilization bandage at 1 minute after injection. Treated animals had elastic bandages applied to the extremity and splinting for immobilization. Vital signs and quality of respirations were recorded. Outcome was the onset of respiratory failure or survival to 8 hours. Necropsies and histologic analysis of the envenomation site was performed. One animal from each group was removed because of the discovery of pre-existing respiratory pathology. Four of 5 pigs in the treatment group survived to 8 hours, but none in the control group survived. Mean time to onset of respiratory compromise was 170.4 +/- 33.3 minutes in the control group. None of the pigs had histologic changes at the envenomation site consistent with ischemia or pressure-related injury. Pressure-immobilization bandages delayed the onset of systemic toxicity in our porcine model of M fulvius envenomation.
de Sadeleer, Nicolas
2012-03-01
In the light of new case law development, this article examines whether national restrictions on the online sale of pharmaceuticals and medical devices such as contact lenses are consistent either with EU secondary law, either with Article 34 TFEU that prohibits measures having equivalent effect to quantitative restrictions on imports. In particular, this article focuses on an analysis of two judgments on this important issue delivered by the Court of Justice of the European Union in 2003 and 2010, namely the Deutscher Apothekerverband decision and the Ker-Optika decision.
Vibrational spectroscopy in the ophthalmological field
NASA Astrophysics Data System (ADS)
Bertoluzza, Alessandro; Monti, P.; Simoni, R.
1991-05-01
Some applications of vibrational (Raman and FT/IR) spectroscopy to the study of biocompatibility in the ophthalmological field are described. The structure arid elastic properties of a new hydrophobic fluorocarbon copolymer (FCC) are presented. Bacterial adhesion on its surface is also considered. The structure arid properties of soft contact lenses based on poly2--hydroxyethylmethacrylate (PHEMA) and polyvinylpyrrolidone (PVP) are discussed in relation to their recent use as intrastromal implants. The preliminary results dealing with a study on protein deposits on soft contact lenses in presence of a collyrium limiting the formation of such deposits are also reported. 1.
Welsh, Lynn
2017-05-01
To analyse current evidence on the efficacy of bandage systems containing both elastic and inelastic components (mixed-component systems). International consensus on the efficacy of types of compression systems is difficult to achieve; however, mixed-component systems are being promoted as combining the best properties of both elastic and inelastic bandage systems and increasingly being used to treat venous leg ulcers in practice. A systematic literature review. Search terms such as venous leg ulcer, varicose ulcer, leg ulcer, compression, bandage, elastic, inelastic, short stretch, healing rate, interface pressure, mixed component, two-layer, four-layer and multi-layer were used in database and hand searches in several combinations. Limits were set for years 2005-March 2015 and English-language publications. A total of 475 studies were identified at initial search, and following elimination from abstract and title, this was reduced to 7. A further study was identified on Google Scholar, bringing the final number of studies fitting inclusion criteria to 8. The following subgroups relating to outcomes of efficacy were identified: ulcer healing, maintenance of interface pressure, slippage, ease of application and patient quality of life. Mixed-component systems were found to have comparable ulcer healing rates to alternative compression systems and be easy to apply; have similar abilities to maintain pressure as four-layer bandages and better abilities than short-stretch bandages; have less slippage than alternative systems; and to be significantly associated with several favourable quality of life outcomes. Clinician skill in bandage application was an uncontrolled variable in all eight papers included in the review, which may limit reliability of findings. This review synthesises existing evidence on the efficacy of mixed-component systems and encourages clinicians to regard them as an effective alternative to purely elastic or inelastic compression systems. Additionally, it highlights the importance of clinician skill in bandage application as a crucial determinant of effective compression. © 2016 John Wiley & Sons Ltd.
Wound-Related Allergic/Irritant Contact Dermatitis.
Alavi, Afsaneh; Sibbald, R Gary; Ladizinski, Barry; Saraiya, Ami; Lee, Kachiu C; Skotnicki-Grant, Sandy; Maibach, Howard
2016-06-01
To provide information from a literature review about the prevention, recognition, and treatment for contact dermatitis. This continuing education activity is intended for physicians and nurses with an interest in skin and wound care. After participating in this educational activity, the participant should be better able to:1. Identify signs and symptoms of and diagnostic measures for contact dermatitis.2. Identify causes and risks for contact dermatitis.3. Select appropriate treatment for contact dermatitis and its prevention. Contact dermatitis to wound care products is a common, often neglected problem. A review was conducted to identify articles relevant to contact dermatitis.A PubMed English-language literature review was conducted for appropriate articles published between January 2000 and December 2015.Contact dermatitis is both irritant (80% of cases) or allergic (20% of cases). Frequent use of potential contact allergens and impaired barrier function of the skin can lead to rising sensitization in patients with chronic wounds. Common known allergens to avoid in wound care patients include fragrances, colophony, lanolin, and topical antibiotics.Clinicians should be cognizant of the allergens in wound care products and the potential for sensitization. All medical devices, including wound dressings, adhesives, and bandages, should be labeled with their complete ingredients, and manufacturers should be encouraged to remove common allergens from wound care products, including topical creams, ointments, and dressings.
Wear effects on microscopic morphology and hyaluronan uptake in siloxane-hydrogel contact lenses.
Tavazzi, Silvia; Tonveronachi, Martina; Fagnola, Matteo; Cozza, Federica; Ferraro, Lorenzo; Borghesi, Alessandro; Ascagni, Miriam; Farris, Stefano
2015-07-01
The purpose of this study was a comparison between new and worn siloxane-hydrogel contact lenses in terms of microscopic structure, surface morphology, and loading of hyaluronan. The analyses were performed by scanning electron microscopy, with the support of the freeze-drying technique, and by fluorescence confocal microscopy. Along the depth profile of new lenses, a thin porous top layer was observed, which corresponds to the region of hyaluronan penetration inside well-defined channels. The time evolution was followed from one day to two weeks of daily wear, when a completely different scenario was found. Clear experimental evidence of a buggy surface was observed with several crests and regions of swelling, which could be filled by the hyaluronan solution. The modifications are attributed to the progressive relaxation of the structure of the polymeric network. © 2014 Wiley Periodicals, Inc.
Tam, Connie; Mun, James J.; Evans, David J.
2010-01-01
Purpose. Contact lens wear predisposes to Pseudomonas aeruginosa keratitis, but the mechanisms involved remain unclear. An in vivo model was used to study lens inoculation conditions enabling disease. Methods. Custom-made hydrogel contact lenses were fitted to rats after incubation in P. aeruginosa approximately 1011 cfu/mL (3 hours) or approximately 103 cfu/mL (24 hours). Another group was inadvertently inoculated with a suction pen previously used with high inocula, but rinsed in ethanol and stored dry (6 months). Some corneas were tissue paper–blotted to cause fluorescein staining before lens fitting. Contralateral eyes were untreated. Twenty-four hours after disease detection, lenses were transferred to naive rats or examined by confocal microscopy before homogenization to quantify viable bacteria. After lens removal, corneas were washed to collect nonadherent bacteria and were analyzed by immunohistochemistry. Results. All eyes challenged with unworn contaminated lenses developed keratitis after approximately 7 to 10 days. Disease delay and severity were unaffected by inoculum parameters or tissue blotting but occurred sooner with lenses transferred from infected eyes (∼2 days). Worn lenses and corneal washes contained infecting bacteria. Posterior, not anterior, lens surfaces harbored P. aeruginosa biofilms that penetrated the lens matrix. Diseased corneas showed an infiltration of phagocytes and T-lymphocytes. Conclusions. P. aeruginosa induces keratitis in this lens-wearing model after a single inoculation. Delayed disease onset was interesting considering the greater keratitis risk during extended wear. Infection did not require the disruption of corneal barrier function before lens wear and occurred without exposure to lens care solutions. The data suggest that keratitis involves biofilm formation or other bacterial adaptations in vivo. PMID:20130275
Corneal inflammatory events with daily silicone hydrogel lens wear.
Szczotka-Flynn, Loretta; Jiang, Ying; Raghupathy, Sangeetha; Bielefeld, Roger A; Garvey, Matthew T; Jacobs, Michael R; Kern, Jami; Debanne, Sara M
2014-01-01
This study aimed to determine the probability and risk factors for developing a corneal inflammatory event (CIE) during daily wear of lotrafilcon A silicone hydrogel contact lenses. Eligible participants (n = 218) were fit with lotrafilcon A lenses for daily wear and followed up for 12 months. Participants were randomized to either a polyhexamethylene biguanide-preserved multipurpose solution or a one-step peroxide disinfection system. The main exposures of interest were bacterial contamination of lenses, cases, lid margins, and ocular surface. Kaplan-Meier (KM) plots were used to estimate the cumulative unadjusted probability of remaining free from a CIE, and multivariate Cox proportional hazards regression was used to model the hazard of experiencing a CIE. The KM unadjusted cumulative probability of remaining free from a CIE for both lens care groups combined was 92.3% (95% confidence interval [CI], 88.1 to 96.5%). There was one participant with microbial keratitis, five participants with asymptomatic infiltrates, and seven participants with contact lens peripheral ulcers, providing KM survival estimates of 92.8% (95% CI, 88.6 to 96.9%) and 98.1% (95% CI, 95.8 to 100.0%) for remaining free from noninfectious and symptomatic CIEs, respectively. The presence of substantial (>100 colony-forming units) coagulase-negative staphylococci bioburden on lid margins was associated with about a five-fold increased risk for the development of a CIE (p = 0.04). The probability of experiencing a CIE during daily wear of lotrafilcon A contact lenses is low, and symptomatic CIEs are rare. Patient factors, such as high levels of bacterial bioburden on lid margins, contribute to the development of noninfectious CIEs during daily wear of silicone hydrogel lenses.
Comparison of 10 Hemostatic Dressings in a Groin Puncture Model in Swine
2009-09-01
attended or remote surgical theaters as well as for first aid bandaging in extreme sport.Methods to suppress massive external hemorrhage should be provided...Products Newport, O Instaclot (IC) Emergency Medical Devices Loxa WoundStat (WS) TraumaCure, Inc. Bethesda, Md Solid (flexible) agents Alpha Bandage ...referred to throughout are listed in Table I. The hemostatic products and the standard compressed gauze bandage (SD; H&H compressed gauze, H&H
Tensiometer for Bandage-Wound Adhesion Studies
2016-04-08
instrument will support research in an active DoD project, “Technologies for Hemostasis and Stabilization of the Acute Traumatic Wound ” (award number: W81XWH...Release; Distribution Unlimited UU UU UU UU 08-04-2016 1-Aug-2014 31-Jul-2015 Final Report: Tensiometer for bandage- wound adhesion studies The views...Report: Tensiometer for bandage- wound adhesion studies Report Title This 2013 DURIP proposal is for the purchase of an Instron model 5943 tensiometer
Dynamic simulation of the effect of soft toric contact lenses movement on retinal image quality.
Niu, Yafei; Sarver, Edwin J; Stevenson, Scott B; Marsack, Jason D; Parker, Katrina E; Applegate, Raymond A
2008-04-01
To report the development of a tool designed to dynamically simulate the effect of soft toric contact lens movement on retinal image quality, initial findings on three eyes, and the next steps to be taken to improve the utility of the tool. Three eyes of two subjects wearing soft toric contact lenses were cyclopleged with 1% cyclopentolate and 2.5% phenylephrine. Four hundred wavefront aberration measurements over a 5-mm pupil were recorded during soft contact lens wear at 30 Hz using a complete ophthalmic analysis system aberrometer. Each wavefront error measurement was input into Visual Optics Laboratory (version 7.15, Sarver and Associates, Inc.) to generate a retinal simulation of a high contrast log MAR visual acuity chart. The individual simulations were combined into a single dynamic movie using a custom MatLab PsychToolbox program. Visual acuity was measured for each eye reading the movie with best cycloplegic spectacle correction through a 3-mm artificial pupil to minimize the influence of the eyes' uncorrected aberrations. Comparison of the simulated acuity was made to values recorded while the subject read unaberrated charts with contact lenses through a 5-mm artificial pupil. For one study eye, average acuity was the same as the natural contact lens viewing condition. For the other two study eyes visual acuity of the best simulation was more than one line worse than natural viewing conditions. Dynamic simulation of retinal image quality, although not yet perfect, is a promising technique for visually illustrating the optical effects on image quality because of the movements of alignment-sensitive corrections.
Which soft lens power is better for piggyback in keratoconus? Part II.
Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; González-Meijóme, Jose-Manuel; Flores-Rodriguez, Patricia; Villa-Collar, Cesar
2015-02-01
To evaluate how soft lens power affects rigid gas-permeable (RGP) lens power and visual acuity (VA) in piggyback fittings for keratoconus. Sixteen keratoconus subjects (30 eyes) were included in the study. Piggyback contact lens fittings combining Senofilcon-A soft lenses of -6.00, -3.00, +3.00 and +6.00 D with Rose K2 RGP contact lenses were performed. Corneal topography was taken on the naked eye and over each soft contact lens before fitting RGP lenses. Mean central keratometry, over-refraction, RGP back optic zone radius (BOZR) and estimated final power as well as VA were recorded and analyzed. In comparison to the naked eye, the mean central keratometry flattened with both negative lens powers (p<0.05 in all cases), did not change with the +3.00 soft lens power (p=1.0); and steepened with the +6.00 soft lens power (p=0.02). Rigid gas-permeable over-refraction did not change significantly between different soft lens powers (all p>0.05). RGP's BOZR decreased significantly with both positive in comparison with both negative soft lens powers (all p<0.001), but no significant differences were found among negative- or positive-powers separately (both p>0.05). Estimated RGP's final power increased significantly with positive in comparison with negative lens powers (all p<0.001), but no significant differences were found among negative or positive lens powers separately (both p>0.05). Visual acuity did not change significantly between the different soft lens powers assessed (all p>0.05). The use of negative-powered soft lenses in piggyback fitting reduces RGP lens power without impacting VA in keratoconus subjects. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
A method for profiling biometric changes during disaccommodation.
Alderson, Alison; Davies, Leon N; Mallen, Edward A H; Sheppard, Amy L
2012-05-01
To demonstrate the application of low-coherence reflectometry to the study of biometric changes during disaccommodation responses in human eyes after cessation of a near task and to evaluate the effect of contact lenses on low-coherence reflectometry biometric measurements. Ocular biometric parameters of crystalline lens thickness (LT) and anterior chamber depth (ACD) were measured with the LenStar device during and immediately after a 5 D accommodative task in 10 participants. In a separate trial, accommodation responses were recorded with a Shin-Nippon WAM-5500 optometer in a subset of two participants. Biometric data were interleaved to form a profile of post-task anterior segment changes. In a further experiment, the effect of soft contact lenses on LenStar measurements was evaluated in 15 participants. In 10 adult participants, increased LT and reduced ACD was seen during the 5 D task. Post-task, during fixation of a 0 D target, a profile of the change in LT and ACD against time was observed. In the two participants with accommodation data (one a sufferer of nearwork-induced transient myopia and other a non-sufferer), the post-task changes in refraction compared favorably with the interleaved LenStar biometry data. The insertion of soft contact lenses did not have a significant effect on LenStar measures of ACD or LT (mean change: -0.007 mm, p = 0.265 and + 0.001 mm, p = 0.875, respectively). With the addition of a relatively simple stimulus modification, the LenStar instrument can be used to produce a profile of post-task changes in LT and ACD. The spatial and temporal resolution of the system is sufficient for the investigation of nearwork-induced transient myopia from a biometric viewpoint. LenStar measurements of ACD and LT remain valid after the fitting of soft contact lenses.