Practical guide to bar coding for patient medication safety.
Neuenschwander, Mark; Cohen, Michael R; Vaida, Allen J; Patchett, Jeffrey A; Kelly, Jamie; Trohimovich, Barbara
2003-04-15
Bar coding for the medication administration step of the drug-use process is discussed. FDA will propose a rule in 2003 that would require bar-code labels on all human drugs and biologicals. Even with an FDA mandate, manufacturer procrastination and possible shifts in product availability are likely to slow progress. Such delays should not preclude health systems from adopting bar-code-enabled point-of-care (BPOC) systems to achieve gains in patient safety. Bar-code technology is a replacement for traditional keyboard data entry. The elements of bar coding are content, which determines the meaning; data format, which refers to the embedded data and symbology, which describes the "font" in which the machine-readable code is written. For a BPOC system to deliver an acceptable level of patient protection, the hospital must first establish reliable processes for a patient identification band, caregiver badge, and medication bar coding. Medications can have either drug-specific or patient-specific bar codes. Both varieties result in the desired code that supports patient's five rights of drug administration. When medications are not available from the manufacturer in immediate-container bar-coded packaging, other means of applying the bar code must be devised, including the use of repackaging equipment, overwrapping, manual bar coding, and outsourcing. Virtually all medications should be bar coded, the bar code on the label should be easily readable, and appropriate policies, procedures, and checks should be in place. Bar coding has the potential to be not only cost-effective but to produce a return on investment. By bar coding patient identification tags, caregiver badges, and immediate-container medications, health systems can substantially increase patient safety during medication administration.
Scanning for safety: an integrated approach to improved bar-code medication administration.
Early, Cynde; Riha, Chris; Martin, Jennifer; Lowdon, Karen W; Harvey, Ellen M
2011-03-01
This is a review of lessons learned in the postimplementation evaluation of a bar-code medication administration technology implemented at a major tertiary-care hospital in 2001. In 2006, with a bar-code medication administration scan compliance rate of 82%, a near-miss sentinel event prompted review of this technology as part of an institutional recommitment to a "culture of safety." Multifaceted problems with bar-code medication administration created an environment of circumventing safeguards as demonstrated by an increase in manual overrides to ensure timely medication administration. A multiprofessional team composed of nursing, pharmacy, human resources, quality, and technical services formalized. Each step in the bar-code medication administration process was reviewed. Technology, process, and educational solutions were identified and implemented systematically. Overall compliance with bar-code medication administration rose from 82% to 97%, which resulted in a calculated cost avoidance of more than $2.8 million during this time frame of the project.
Effect of bar-code technology on the safety of medication administration.
Poon, Eric G; Keohane, Carol A; Yoon, Catherine S; Ditmore, Matthew; Bane, Anne; Levtzion-Korach, Osnat; Moniz, Thomas; Rothschild, Jeffrey M; Kachalia, Allen B; Hayes, Judy; Churchill, William W; Lipsitz, Stuart; Whittemore, Anthony D; Bates, David W; Gandhi, Tejal K
2010-05-06
Serious medication errors are common in hospitals and often occur during order transcription or administration of medication. To help prevent such errors, technology has been developed to verify medications by incorporating bar-code verification technology within an electronic medication-administration system (bar-code eMAR). We conducted a before-and-after, quasi-experimental study in an academic medical center that was implementing the bar-code eMAR. We assessed rates of errors in order transcription and medication administration on units before and after implementation of the bar-code eMAR. Errors that involved early or late administration of medications were classified as timing errors and all others as nontiming errors. Two clinicians reviewed the errors to determine their potential to harm patients and classified those that could be harmful as potential adverse drug events. We observed 14,041 medication administrations and reviewed 3082 order transcriptions. Observers noted 776 nontiming errors in medication administration on units that did not use the bar-code eMAR (an 11.5% error rate) versus 495 such errors on units that did use it (a 6.8% error rate)--a 41.4% relative reduction in errors (P<0.001). The rate of potential adverse drug events (other than those associated with timing errors) fell from 3.1% without the use of the bar-code eMAR to 1.6% with its use, representing a 50.8% relative reduction (P<0.001). The rate of timing errors in medication administration fell by 27.3% (P<0.001), but the rate of potential adverse drug events associated with timing errors did not change significantly. Transcription errors occurred at a rate of 6.1% on units that did not use the bar-code eMAR but were completely eliminated on units that did use it. Use of the bar-code eMAR substantially reduced the rate of errors in order transcription and in medication administration as well as potential adverse drug events, although it did not eliminate such errors. Our data show that the bar-code eMAR is an important intervention to improve medication safety. (ClinicalTrials.gov number, NCT00243373.) 2010 Massachusetts Medical Society
Time trend of injection drug errors before and after implementation of bar-code verification system.
Sakushima, Ken; Umeki, Reona; Endoh, Akira; Ito, Yoichi M; Nasuhara, Yasuyuki
2015-01-01
Bar-code technology, used for verification of patients and their medication, could prevent medication errors in clinical practice. Retrospective analysis of electronically stored medical error reports was conducted in a university hospital. The number of reported medication errors of injected drugs, including wrong drug administration and administration to the wrong patient, was compared before and after implementation of the bar-code verification system for inpatient care. A total of 2867 error reports associated with injection drugs were extracted. Wrong patient errors decreased significantly after implementation of the bar-code verification system (17.4/year vs. 4.5/year, p< 0.05), although wrong drug errors did not decrease sufficiently (24.2/year vs. 20.3/year). The source of medication errors due to wrong drugs was drug preparation in hospital wards. Bar-code medication administration is effective for prevention of wrong patient errors. However, ordinary bar-code verification systems are limited in their ability to prevent incorrect drug preparation in hospital wards.
The Effects of Bar-coding Technology on Medication Errors: A Systematic Literature Review.
Hutton, Kevin; Ding, Qian; Wellman, Gregory
2017-02-24
The bar-coding technology adoptions have risen drastically in U.S. health systems in the past decade. However, few studies have addressed the impact of bar-coding technology with strong prospective methodologies and the research, which has been conducted from both in-pharmacy and bedside implementations. This systematic literature review is to examine the effectiveness of bar-coding technology on preventing medication errors and what types of medication errors may be prevented in the hospital setting. A systematic search of databases was performed from 1998 to December 2016. Studies measuring the effect of bar-coding technology on medication errors were included in a full-text review. Studies with the outcomes other than medication errors such as efficiency or workarounds were excluded. The outcomes were measured and findings were summarized for each retained study. A total of 2603 articles were initially identified and 10 studies, which used prospective before-and-after study design, were fully reviewed in this article. Of the 10 included studies, 9 took place in the United States, whereas the remaining was conducted in the United Kingdom. One research article focused on bar-coding implementation in a pharmacy setting, whereas the other 9 focused on bar coding within patient care areas. All 10 studies showed overall positive effects associated with bar-coding implementation. The results of this review show that bar-coding technology may reduce medication errors in hospital settings, particularly on preventing targeted wrong dose, wrong drug, wrong patient, unauthorized drug, and wrong route errors.
Song, Lunar; Park, Byeonghwa; Oh, Kyeung Mi
2015-04-01
Serious medication errors continue to exist in hospitals, even though there is technology that could potentially eliminate them such as bar code medication administration. Little is known about the degree to which the culture of patient safety is associated with behavioral intention to use bar code medication administration. Based on the Technology Acceptance Model, this study evaluated the relationships among patient safety culture and perceived usefulness and perceived ease of use, and behavioral intention to use bar code medication administration technology among nurses in hospitals. Cross-sectional surveys with a convenience sample of 163 nurses using bar code medication administration were conducted. Feedback and communication about errors had a positive impact in predicting perceived usefulness (β=.26, P<.01) and perceived ease of use (β=.22, P<.05). In a multiple regression model predicting for behavioral intention, age had a negative impact (β=-.17, P<.05); however, teamwork within hospital units (β=.20, P<.05) and perceived usefulness (β=.35, P<.01) both had a positive impact on behavioral intention. The overall bar code medication administration behavioral intention model explained 24% (P<.001) of the variance. Identified factors influencing bar code medication administration behavioral intention can help inform hospitals to develop tailored interventions for RNs to reduce medication administration errors and increase patient safety by using this technology.
Nurses' attitudes toward the use of the bar-coding medication administration system.
Marini, Sana Daya; Hasman, Arie; Huijer, Huda Abu-Saad; Dimassi, Hani
2010-01-01
This study determines nurses' attitudes toward bar-coding medication administration system use. Some of the factors underlying the successful use of bar-coding medication administration systems that are viewed as a connotative indicator of users' attitudes were used to gather data that describe the attitudinal basis for system adoption and use decisions in terms of subjective satisfaction. Only 67 nurses in the United States had the chance to respond to the e-questionnaire posted on the CARING list server for the months of June and July 2007. Participants rated their satisfaction with bar-coding medication administration system use based on system functionality, usability, and its positive/negative impact on the nursing practice. Results showed, to some extent, positive attitude, but the image profile draws attention to nurses' concerns for improving certain system characteristics. The high bar-coding medication administration system skills revealed a more negative perception of the system by the nursing staff. The reasons underlying dissatisfaction with bar-coding medication administration use by skillful users are an important source of knowledge that can be helpful for system development as well as system deployment. As a result, strengthening bar-coding medication administration system usability by magnifying its ability to eliminate medication errors and the contributing factors, maximizing system functionality by ascertaining its power as an extra eye in the medication administration process, and impacting the clinical nursing practice positively by being helpful to nurses, speeding up the medication administration process, and being user-friendly can offer a congenial settings for establishing positive attitude toward system use, which in turn leads to successful bar-coding medication administration system use.
Angel, Vini M; Friedman, Marvin H; Friedman, Andrea L
This article describes an innovative project involving the integration of bar-code medication administration technology competencies in the nursing curriculum through interprofessional collaboration among nursing, pharmacy, and computer science disciplines. A description of the bar-code medication administration technology project and lessons learned are presented.
Accuracy and time requirements of a bar-code inventory system for medical supplies.
Hanson, L B; Weinswig, M H; De Muth, J E
1988-02-01
The effects of implementing a bar-code system for issuing medical supplies to nursing units at a university teaching hospital were evaluated. Data on the time required to issue medical supplies to three nursing units at a 480-bed, tertiary-care teaching hospital were collected (1) before the bar-code system was implemented (i.e., when the manual system was in use), (2) one month after implementation, and (3) four months after implementation. At the same times, the accuracy of the central supply perpetual inventory was monitored using 15 selected items. One-way analysis of variance tests were done to determine any significant differences between the bar-code and manual systems. Using the bar-code system took longer than using the manual system because of a significant difference in the time required for order entry into the computer. Multiple-use requirements of the central supply computer system made entering bar-code data a much slower process. There was, however, a significant improvement in the accuracy of the perpetual inventory. Using the bar-code system for issuing medical supplies to the nursing units takes longer than using the manual system. However, the accuracy of the perpetual inventory was significantly improved with the implementation of the bar-code system.
The Impact of Bar Code Medication Administration Technology on Reported Medication Errors
ERIC Educational Resources Information Center
Holecek, Andrea
2011-01-01
The use of bar-code medication administration technology is on the rise in acute care facilities in the United States. The technology is purported to decrease medication errors that occur at the point of administration. How significantly this technology affects actual rate and severity of error is unknown. This descriptive, longitudinal research…
Ma, Pei-Luen; Jheng, Yan-Wun; Jheng, Bi-Wei; Hou, I-Ching
2017-01-01
Bar code medication administration (BCMA) could reduce medical errors and promote patient safety. This research uses modified information systems success model (M-ISS model) to evaluate nurses' acceptance to BCMA. The result showed moderate correlation between medication administration safety (MAS) to system quality, information quality, service quality, user satisfaction, and limited satisfaction.
A Cost-Benefit Between Pyxis and Bar Coding for the Brooke Army Medical Center Operating Room
2005-04-29
38 C onclusions ...................................................................................... 39 A ppendices ...designed for the care of patients Pyxis vs. Bar Coding 8 by surgical practitioners, namely the acute care hospitals. Thus, hospital facilities began to
Kelly, Kandace; Harrington, Linda; Matos, Pat; Turner, Barbara; Johnson, Constance
2016-01-01
Bar-code medication administration (BCMA) effectiveness is contingent upon compliance with best-practice protocols. We developed a 4-phased BCMA evaluation program to evaluate the degree of integration of current evidence into BCMA policies, procedures, and practices; identify barriers to best-practice BCMA use; and modify BCMA practice in concert with changes to the practice environment. This program provides an infrastructure for frontline nurses to partner with hospital leaders to continually evaluate and improve BCMA using a systematic process.
Hara, Liuichi; Guirguis, Ramy; Hummel, Keith; Villanueva, Monica
2017-12-28
The United Nations Population Fund (UNFPA) and the United States Agency for International Development (USAID) DELIVER PROJECT work together to strengthen public health commodity supply chains by standardizing bar coding under a single set of global standards. From 2015, UNFPA and USAID collaborated to pilot test how tracking and tracing of bar coded health products could be operationalized in the public health supply chains of Ethiopia and Pakistan and inform the ecosystem needed to begin full implementation. Pakistan had been using proprietary bar codes for inventory management of contraceptive supplies but transitioned to global standards-based bar codes during the pilot. The transition allowed Pakistan to leverage the original bar codes that were preprinted by global manufacturers as opposed to printing new bar codes at the central warehouse. However, barriers at lower service delivery levels prevented full realization of end-to-end data visibility. Key barriers at the district level were the lack of a digital inventory management system and absence of bar codes at the primary-level packaging level, such as single blister packs. The team in Ethiopia developed an open-sourced smartphone application that allowed the team to scan bar codes using the mobile phone's camera and to push the captured data to the country's data mart. Real-time tracking and tracing occurred from the central warehouse to the Addis Ababa distribution hub and to 2 health centers. These pilots demonstrated that standardized product identification and bar codes can significantly improve accuracy over manual stock counts while significantly streamlining the stock-taking process, resulting in efficiencies. The pilots also showed that bar coding technology by itself is not sufficient to ensure data visibility. Rather, by using global standards for identification and data capture of pharmaceuticals and medical devices, and integrating the data captured into national and global tracking systems, countries are able to lay the foundation for interoperability and ensure a harmonized language between global health stakeholders. © Hara et al.
Hara, Liuichi; Guirguis, Ramy; Hummel, Keith; Villanueva, Monica
2017-01-01
The United Nations Population Fund (UNFPA) and the United States Agency for International Development (USAID) DELIVER PROJECT work together to strengthen public health commodity supply chains by standardizing bar coding under a single set of global standards. From 2015, UNFPA and USAID collaborated to pilot test how tracking and tracing of bar coded health products could be operationalized in the public health supply chains of Ethiopia and Pakistan and inform the ecosystem needed to begin full implementation. Pakistan had been using proprietary bar codes for inventory management of contraceptive supplies but transitioned to global standards-based bar codes during the pilot. The transition allowed Pakistan to leverage the original bar codes that were preprinted by global manufacturers as opposed to printing new bar codes at the central warehouse. However, barriers at lower service delivery levels prevented full realization of end-to-end data visibility. Key barriers at the district level were the lack of a digital inventory management system and absence of bar codes at the primary-level packaging level, such as single blister packs. The team in Ethiopia developed an open-sourced smartphone application that allowed the team to scan bar codes using the mobile phone's camera and to push the captured data to the country's data mart. Real-time tracking and tracing occurred from the central warehouse to the Addis Ababa distribution hub and to 2 health centers. These pilots demonstrated that standardized product identification and bar codes can significantly improve accuracy over manual stock counts while significantly streamlining the stock-taking process, resulting in efficiencies. The pilots also showed that bar coding technology by itself is not sufficient to ensure data visibility. Rather, by using global standards for identification and data capture of pharmaceuticals and medical devices, and integrating the data captured into national and global tracking systems, countries are able to lay the foundation for interoperability and ensure a harmonized language between global health stakeholders. PMID:29284701
Telepharmacy and bar-code technology in an i.v. chemotherapy admixture area.
O'Neal, Brian C; Worden, John C; Couldry, Rick J
2009-07-01
A program using telepharmacy and bar-code technology to increase the presence of the pharmacist at a critical risk point during chemotherapy preparation is described. Telepharmacy hardware and software were acquired, and an inspection camera was placed in a biological safety cabinet to allow the pharmacy technician to take digital photographs at various stages of the chemotherapy preparation process. Once the pharmacist checks the medication vials' agreement with the work label, the technician takes the product into the biological safety cabinet, where the appropriate patient is selected from the pending work list, a queue of patient orders sent from the pharmacy information system. The technician then scans the bar code on the vial. Assuming the bar code matches, the technician photographs the work label, vials, diluents and fluids to be used, and the syringe (before injecting the contents into the bag) along with the vial. The pharmacist views all images as a part of the final product-checking process. This process allows the pharmacist to verify that the correct quantity of medication was transferred from the primary source to a secondary container without being physically present at the time of transfer. Telepharmacy and bar coding provide a means to improve the accuracy of chemotherapy preparation by decreasing the likelihood of using the incorrect product or quantity of drug. The system facilitates the reading of small product labels and removes the need for a pharmacist to handle contaminated syringes and vials when checking the final product.
Leirer, V O; Morrow, D G; Pariante, G M; Sheikh, J I
1988-10-01
This study investigates three questions related to the problem of medication nonadherence among elders. First, does recall failure play a significant role in nonadherence? Recent research suggests that it may not. Second, can the new portable bar code scanner technology be used to study nonadherence? Other forms of monitoring are obtrusive or inaccurate. Finally, can inexpensive computer assisted instructions (CAI) be used to teach mnemonic techniques specifically designed to improve medication schedule recall? Current research on memory training teaches nonspecific mnemonics and uses the expensive classroom approach. Results of the present study suggest that physically active and cognitively alert elders do have significant nonadherence (control group = 32.0%) problems related to forgetting and that CAI courseware can significantly reduce (medication recall training group = 10.0%) this form of nonadherence. Portable bar code technology proved easy to use by elderly patients and provided detailed information about the type of forgetting underlying nonadherence. Most significant recall failure was in the complete forgetting to take medication rather than delays in medicating or overmedicating.
Miller, Daniel F; Fortier, Christopher R; Garrison, Kelli L
2011-02-01
Bar code medication administration (BCMA) technology is gaining acceptance for its ability to prevent medication administration errors. However, studies suggest that improper use of BCMA technology can yield unsatisfactory error prevention and introduction of new potential medication errors. To evaluate the incidence of high-alert medication BCMA triggers and alert types and discuss the type of nursing and pharmacy workarounds occurring with the use of BCMA technology and the electronic medication administration record (eMAR). Medication scanning and override reports from January 1, 2008, through November 30, 2008, for all adult medical/surgical units were retrospectively evaluated for high-alert medication system triggers, alert types, and override reason documentation. An observational study of nursing workarounds on an adult medicine step-down unit was performed and an analysis of potential pharmacy workarounds affecting BCMA and the eMAR was also conducted. Seventeen percent of scanned medications triggered an error alert of which 55% were for high-alert medications. Insulin aspart, NPH insulin, hydromorphone, potassium chloride, and morphine were the top 5 high-alert medications that generated alert messages. Clinician override reasons for alerts were documented in only 23% of administrations. Observational studies assessing for nursing workarounds revealed a median of 3 clinician workarounds per administration. Specific nursing workarounds included a failure to scan medications/patient armband and scanning the bar code once the dosage has been removed from the unit-dose packaging. Analysis of pharmacy order entry process workarounds revealed the potential for missed doses, duplicate doses, and doses being scheduled at the wrong time. BCMA has the potential to prevent high-alert medication errors by alerting clinicians through alert messages. Nursing and pharmacy workarounds can limit the recognition of optimal safety outcomes and therefore workflow processes must be continually analyzed and restructured to yield the intended full benefits of BCMA technology. © 2011 SAGE Publications.
Dupuis, S; Fecci, J-L; Noyer, P; Lecarpentier, E; Chollet-Xémard, C; Margenet, A; Marty, J; Combes, X
2009-01-01
To assess economical impact after introduction of a bar coding pharmacy stock replenishment system in a prehospital emergency medical unit. Observational before and after study. A computer system using specific software and bare-code technology was introduced in the pre hospital emergency medical unit (Smur). Overall activity and costs related to pharmacy were recorded annually during two periods: the first 2 years period before computer system introduction and the second one during the 4 years following this system installation. The overall clinical activity increased by 10% between the two periods whereas pharmacy related costs continuously decreased after the start of pharmacy management computer system use. Pharmacy stock management was easier after introduction of the new stock replenishment system. The mean pharmacy related cost of one patient management was 13 Euros before and 9 Euros after the introduction of the system. The overall cost savings during the studied period was calculated to reach 134,000 Euros. The introduction of a specific pharmacy management computer system allowed to do important costs savings in a prehospital emergency medical unit.
Hayden, Randall T; Patterson, Donna J; Jay, Dennis W; Cross, Carl; Dotson, Pamela; Possel, Robert E; Srivastava, Deo Kumar; Mirro, Joseph; Shenep, Jerry L
2008-02-01
To assess the ability of a bar code-based electronic positive patient and specimen identification (EPPID) system to reduce identification errors in a pediatric hospital's clinical laboratory. An EPPID system was implemented at a pediatric oncology hospital to reduce errors in patient and laboratory specimen identification. The EPPID system included bar-code identifiers and handheld personal digital assistants supporting real-time order verification. System efficacy was measured in 3 consecutive 12-month time frames, corresponding to periods before, during, and immediately after full EPPID implementation. A significant reduction in the median percentage of mislabeled specimens was observed in the 3-year study period. A decline from 0.03% to 0.005% (P < .001) was observed in the 12 months after full system implementation. On the basis of the pre-intervention detected error rate, it was estimated that EPPID prevented at least 62 mislabeling events during its first year of operation. EPPID decreased the rate of misidentification of clinical laboratory samples. The diminution of errors observed in this study provides support for the development of national guidelines for the use of bar coding for laboratory specimens, paralleling recent recommendations for medication administration.
Driving out errors through tight integration between software and automation.
Reifsteck, Mark; Swanson, Thomas; Dallas, Mary
2006-01-01
A clear case has been made for using clinical IT to improve medication safety, particularly bar-code point-of-care medication administration and computerized practitioner order entry (CPOE) with clinical decision support. The equally important role of automation has been overlooked. When the two are tightly integrated, with pharmacy information serving as a hub, the distinctions between software and automation become blurred. A true end-to-end medication management system drives out errors from the dockside to the bedside. Presbyterian Healthcare Services in Albuquerque has been building such a system since 1999, beginning by automating pharmacy operations to support bar-coded medication administration. Encouraged by those results, it then began layering on software to further support clinician workflow and improve communication, culminating with the deployment of CPOE and clinical decision support. This combination, plus a hard-wired culture of safety, has resulted in a dramatically lower mortality and harm rate that could not have been achieved with a partial solution.
Bar code, good for industry and trade--how does it benefit the dentist?
Oehlmann, H
2001-10-01
Every dentist who attentively follows the change in product labelling can easily see that the HIBC bar code is on the increase. In fact, according to information from FIDE/VDDI and ADE/BVD, the dental industry and trade are firmly resolved to apply the HIBC bar code to all products used internationally in dental practices. Why? Indeed, at first it looks like extra expense to additionally print a bar code on the packages. Good reasons can only lie in advantages which manufacturers and the trade expect from the HIBC bar code, Indications in dental technician circles are that the HIBC bar code is coming. If there are advantages, what are these, and can the dentist also profit from them? What does HIBC bar code mean and what items of interest does it include? What does bar code cost and does only one code exist? This is explained briefly, concentrating on the benefits bar code can bring for different users.
The impact of medical tourism and the code of medical ethics on advertisement in Nigeria
Makinde, Olusesan Ayodeji; Brown, Brandon; Olaleye, Olalekan
2014-01-01
Advances in management of clinical conditions are being made in several resource poor countries including Nigeria. Yet, the code of medical ethics which bars physician and health practices from advertising the kind of services they render deters these practices. This is worsened by the incursion of medical tourism facilitators (MTF) who continue to market healthcare services across countries over the internet and social media thereby raising ethical questions. A significant review of the advertisement ban in the code of ethics is long overdue. Limited knowledge about advances in medical practice among physicians and the populace, the growing medical tourism industry and its attendant effects, and the possibility of driving brain gain provide evidence to repeal the code. Ethical issues, resistance to change and elitist ideas are mitigating factors working in the opposite direction. The repeal of the code of medical ethics against advertising will undoubtedly favor health facilities in the country that currently cannot advertise the kind of services they render. A repeal or review of this code of medical ethics is necessary with properly laid down guidelines on how advertisements can be and cannot be done. PMID:25722776
The impact of medical tourism and the code of medical ethics on advertisement in Nigeria.
Makinde, Olusesan Ayodeji; Brown, Brandon; Olaleye, Olalekan
2014-01-01
Advances in management of clinical conditions are being made in several resource poor countries including Nigeria. Yet, the code of medical ethics which bars physician and health practices from advertising the kind of services they render deters these practices. This is worsened by the incursion of medical tourism facilitators (MTF) who continue to market healthcare services across countries over the internet and social media thereby raising ethical questions. A significant review of the advertisement ban in the code of ethics is long overdue. Limited knowledge about advances in medical practice among physicians and the populace, the growing medical tourism industry and its attendant effects, and the possibility of driving brain gain provide evidence to repeal the code. Ethical issues, resistance to change and elitist ideas are mitigating factors working in the opposite direction. The repeal of the code of medical ethics against advertising will undoubtedly favor health facilities in the country that currently cannot advertise the kind of services they render. A repeal or review of this code of medical ethics is necessary with properly laid down guidelines on how advertisements can be and cannot be done.
[Trial of eye drops recognizer for visually disabled persons].
Okamoto, Norio; Suzuki, Katsuhiko; Mimura, Osamu
2009-01-01
The development of a device to enable the visually disabled to differentiate eye drops and their dose. The new instrument is composed of a voice generator and a two-dimensional bar-code reader (LS9208). We designed voice outputs for the visually disabled to state when (number of times) and where (right, left, or both) to administer eye drops. We then determined the minimum bar-code size that can be recognized. After attaching bar-codes of the appropriate size to the lateral or bottom surface of the eye drops container, the readability of the bar-codes was compared. The minimum discrimination bar-code size was 6 mm high x 8.5 mm long. Bar-codes on the bottom surface could be more easily recognized than bar-codes on the side. Our newly-developed device using bar-codes enables visually disabled persons to differentiate eye drops and their doses.
Bepko, Robert J; Moore, John R; Coleman, John R
2009-01-01
This article reports an intervention to improve the quality and safety of hospital patient care by introducing the use of pharmacy robotics into the medication distribution process. Medication safety is vitally important. The integration of pharmacy robotics with computerized practitioner order entry and bedside medication bar coding produces a significant reduction in medication errors. The creation of a safe medication-from initial ordering to bedside administration-provides enormous benefits to patients, to health care providers, and to the organization as well.
Bar Coding and Tracking in Pathology.
Hanna, Matthew G; Pantanowitz, Liron
2016-03-01
Bar coding and specimen tracking are intricately linked to pathology workflow and efficiency. In the pathology laboratory, bar coding facilitates many laboratory practices, including specimen tracking, automation, and quality management. Data obtained from bar coding can be used to identify, locate, standardize, and audit specimens to achieve maximal laboratory efficiency and patient safety. Variables that need to be considered when implementing and maintaining a bar coding and tracking system include assets to be labeled, bar code symbologies, hardware, software, workflow, and laboratory and information technology infrastructure as well as interoperability with the laboratory information system. This article addresses these issues, primarily focusing on surgical pathology. Copyright © 2016 Elsevier Inc. All rights reserved.
Bar Coding and Tracking in Pathology.
Hanna, Matthew G; Pantanowitz, Liron
2015-06-01
Bar coding and specimen tracking are intricately linked to pathology workflow and efficiency. In the pathology laboratory, bar coding facilitates many laboratory practices, including specimen tracking, automation, and quality management. Data obtained from bar coding can be used to identify, locate, standardize, and audit specimens to achieve maximal laboratory efficiency and patient safety. Variables that need to be considered when implementing and maintaining a bar coding and tracking system include assets to be labeled, bar code symbologies, hardware, software, workflow, and laboratory and information technology infrastructure as well as interoperability with the laboratory information system. This article addresses these issues, primarily focusing on surgical pathology. Copyright © 2015 Elsevier Inc. All rights reserved.
19 CFR 142.45 - Use of bar code by entry filer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 2 2010-04-01 2010-04-01 false Use of bar code by entry filer. 142.45 Section 142... THE TREASURY (CONTINUED) ENTRY PROCESS Line Release § 142.45 Use of bar code by entry filer. (a... with instructions from the port director, shall preprint invoices with the C-4 Code in bar code and...
Kim, Myoung Soo
2012-08-01
The purpose of this cross-sectional study was to examine current status of IT-based medication error prevention system construction and the relationships among system construction, medication error management climate and perception for system use. The participants were 124 patient safety chief managers working for 124 hospitals with over 300 beds in Korea. The characteristics of the participants, construction status and perception of systems (electric pharmacopoeia, electric drug dosage calculation system, computer-based patient safety reporting and bar-code system) and medication error management climate were measured in this study. The data were collected between June and August 2011. Descriptive statistics, partial Pearson correlation and MANCOVA were used for data analysis. Electric pharmacopoeia were constructed in 67.7% of participating hospitals, computer-based patient safety reporting systems were constructed in 50.8%, electric drug dosage calculation systems were in use in 32.3%. Bar-code systems showed up the lowest construction rate at 16.1% of Korean hospitals. Higher rates of construction of IT-based medication error prevention systems resulted in greater safety and a more positive error management climate prevailed. The supportive strategies for improving perception for use of IT-based systems would add to system construction, and positive error management climate would be more easily promoted.
ERIC Educational Resources Information Center
VanBiervliet, Alan
A project to develop and evaluate a bar code reader system as a self-directed information and instructional aid for handicapped nonreaders is described. The bar code technology involves passing a light sensitive pen or laser over a printed code with bars which correspond to coded numbers. A system would consist of a portable device which could…
NASA Technical Reports Server (NTRS)
1988-01-01
American Bar Codes, Inc. developed special bar code labels for inventory control of space shuttle parts and other space system components. ABC labels are made in a company-developed anodizing aluminum process and consecutively marketed with bar code symbology and human readable numbers. They offer extreme abrasion resistance and indefinite resistance to ultraviolet radiation, capable of withstanding 700 degree temperatures without deterioration and up to 1400 degrees with special designs. They offer high resistance to salt spray, cleaning fluids and mild acids. ABC is now producing these bar code labels commercially or industrial customers who also need labels to resist harsh environments.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-17
...] Agency Information Collection Activities; Proposed Collection; Comment Request; Bar Code Label... allow 60 days for public comment in response to the notice. This notice solicits comments on the bar... technology. Bar Code Label Requirement for Human Drug and Biological Products--(OMB Control Number 0910-0537...
21 CFR 610.67 - Bar code label requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... or to blood and blood components intended for transfusion. For blood and blood components intended...) BIOLOGICS GENERAL BIOLOGICAL PRODUCTS STANDARDS Labeling Standards § 610.67 Bar code label requirements. Biological products must comply with the bar code requirements at § 201.25 of this chapter. However, the bar...
21 CFR 610.67 - Bar code label requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... or to blood and blood components intended for transfusion. For blood and blood components intended...) BIOLOGICS GENERAL BIOLOGICAL PRODUCTS STANDARDS Labeling Standards § 610.67 Bar code label requirements. Biological products must comply with the bar code requirements at § 201.25 of this chapter. However, the bar...
21 CFR 610.67 - Bar code label requirements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... or to blood and blood components intended for transfusion. For blood and blood components intended...) BIOLOGICS GENERAL BIOLOGICAL PRODUCTS STANDARDS Labeling Standards § 610.67 Bar code label requirements. Biological products must comply with the bar code requirements at § 201.25 of this chapter. However, the bar...
Effects of a direct refill program for automated dispensing cabinets on medication-refill errors.
Helmons, Pieter J; Dalton, Ashley J; Daniels, Charles E
2012-10-01
The effects of a direct refill program for automated dispensing cabinets (ADCs) on medication-refill errors were studied. This study was conducted in designated acute care areas of a 386-bed academic medical center. A wholesaler-to-ADC direct refill program, consisting of prepackaged delivery of medications and bar-code-assisted ADC refilling, was implemented in the inpatient pharmacy of the medical center in September 2009. Medication-refill errors in 26 ADCs from the general medicine units, the infant special care unit, the surgical and burn intensive care units, and intermediate units were assessed before and after the implementation of this program. Medication-refill errors were defined as an ADC pocket containing the wrong drug, wrong strength, or wrong dosage form. ADC refill errors decreased by 77%, from 62 errors per 6829 refilled pockets (0.91%) to 8 errors per 3855 refilled pockets (0.21%) (p < 0.0001). The predominant error type detected before the intervention was the incorrect medication (wrong drug, wrong strength, or wrong dosage form) in the ADC pocket. Of the 54 incorrect medications found before the intervention, 38 (70%) were loaded in a multiple-drug drawer. After the implementation of the new refill process, 3 of the 5 incorrect medications were loaded in a multiple-drug drawer. There were 3 instances of expired medications before and only 1 expired medication after implementation of the program. A redesign of the ADC refill process using a wholesaler-to-ADC direct refill program that included delivery of prepackaged medication and bar-code-assisted refill significantly decreased the occurrence of ADC refill errors.
Multiplexed Detection of Cytokines Based on Dual Bar-Code Strategy and Single-Molecule Counting.
Li, Wei; Jiang, Wei; Dai, Shuang; Wang, Lei
2016-02-02
Cytokines play important roles in the immune system and have been regarded as biomarkers. While single cytokine is not specific and accurate enough to meet the strict diagnosis in practice, in this work, we constructed a multiplexed detection method for cytokines based on dual bar-code strategy and single-molecule counting. Taking interferon-γ (IFN-γ) and tumor necrosis factor-α (TNF-α) as model analytes, first, the magnetic nanobead was functionalized with the second antibody and primary bar-code strands, forming a magnetic nanoprobe. Then, through the specific reaction of the second antibody and the antigen that fixed by the primary antibody, sandwich-type immunocomplex was formed on the substrate. Next, the primary bar-code strands as amplification units triggered multibranched hybridization chain reaction (mHCR), producing nicked double-stranded polymers with multiple branched arms, which were served as secondary bar-code strands. Finally, the secondary bar-code strands hybridized with the multimolecule labeled fluorescence probes, generating enhanced fluorescence signals. The numbers of fluorescence dots were counted one by one for quantification with epi-fluorescence microscope. By integrating the primary and secondary bar-code-based amplification strategy and the multimolecule labeled fluorescence probes, this method displayed an excellent sensitivity with the detection limits were both 5 fM. Unlike the typical bar-code assay that the bar-code strands should be released and identified on a microarray, this method is more direct. Moreover, because of the selective immune reaction and the dual bar-code mechanism, the resulting method could detect the two targets simultaneously. Multiple analysis in human serum was also performed, suggesting that our strategy was reliable and had a great potential application in early clinical diagnosis.
The design of the CMOS wireless bar code scanner applying optical system based on ZigBee
NASA Astrophysics Data System (ADS)
Chen, Yuelin; Peng, Jian
2008-03-01
The traditional bar code scanner is influenced by the length of data line, but the farthest distance of the wireless bar code scanner of wireless communication is generally between 30m and 100m on the market. By rebuilding the traditional CCD optical bar code scanner, a CMOS code scanner is designed based on the ZigBee to meet the demands of market. The scan system consists of the CMOS image sensor and embedded chip S3C2401X, when the two dimensional bar code is read, the results show the inaccurate and wrong code bar, resulted from image defile, disturber, reads image condition badness, signal interference, unstable system voltage. So we put forward the method which uses the matrix evaluation and Read-Solomon arithmetic to solve them. In order to construct the whole wireless optics of bar code system and to ensure its ability of transmitting bar code image signals digitally with long distances, ZigBee is used to transmit data to the base station, and this module is designed based on image acquisition system, and at last the wireless transmitting/receiving CC2430 module circuit linking chart is established. And by transplanting the embedded RTOS system LINUX to the MCU, an applying wireless CMOS optics bar code scanner and multi-task system is constructed. Finally, performance of communication is tested by evaluation software Smart RF. In broad space, every ZIGBEE node can realize 50m transmission with high reliability. When adding more ZigBee nodes, the transmission distance can be several thousands of meters long.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... Request; Bar Code Label Requirement for Human Drug and Biological Products AGENCY: Food and Drug... and clearance. Bar Code Label Requirement for Human Drug and Biological Products--(OMB Control Number... that required human drug product and biological product labels to have bar codes. The rule required bar...
The cost of implementing inpatient bar code medication administration.
Sakowski, Julie Ann; Ketchel, Alan
2013-02-01
To calculate the costs associated with implementing and operating an inpatient bar-code medication administration (BCMA) system in the community hospital setting and to estimate the cost per harmful error prevented. This is a retrospective, observational study. Costs were calculated from the hospital perspective and a cost-consequence analysis was performed to estimate the cost per preventable adverse drug event averted. Costs were collected from financial records and key informant interviews at 4 not-for profit community hospitals. Costs included direct expenditures on capital, infrastructure, additional personnel, and the opportunity costs of time for existing personnel working on the project. The number of adverse drug events prevented using BCMA was estimated by multiplying the number of doses administered using BCMA by the rate of harmful errors prevented by interventions in response to system warnings. Our previous work found that BCMA identified and intercepted medication errors in 1.1% of doses administered, 9% of which potentially could have resulted in lasting harm. The cost of implementing and operating BCMA including electronic pharmacy management and drug repackaging over 5 years is $40,000 (range: $35,600 to $54,600) per BCMA-enabled bed and $2000 (range: $1800 to $2600) per harmful error prevented. BCMA can be an effective and potentially cost-saving tool for preventing the harm and costs associated with medication errors.
Reading color barcodes using visual snakes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schaub, Hanspeter
2004-05-01
Statistical pressure snakes are used to track a mono-color target in an unstructured environment using a video camera. The report discusses an algorithm to extract a bar code signal that is embedded within the target. The target is assumed to be rectangular in shape, with the bar code printed in a slightly different saturation and value in HSV color space. Thus, the visual snake, which primarily weighs hue tracking errors, will not be deterred by the presence of the color bar codes in the target. The bar code is generate with the standard 3 of 9 method. Using this method,more » the numeric bar codes reveal if the target is right-side-up or up-side-down.« less
Bar-Code System for a Microbiological Laboratory
NASA Technical Reports Server (NTRS)
Law, Jennifer; Kirschner, Larry
2007-01-01
A bar-code system has been assembled for a microbiological laboratory that must examine a large number of samples. The system includes a commercial bar-code reader, computer hardware and software components, plus custom-designed database software. The software generates a user-friendly, menu-driven interface.
Zhu, Debin; Tang, Yabing; Xing, Da; Chen, Wei R
2008-05-15
A bio bar code assay based on oligonucleotide-modified gold nanoparticles (Au-NPs) provides a PCR-free method for quantitative detection of nucleic acid targets. However, the current bio bar code assay requires lengthy experimental procedures including the preparation and release of bar code DNA probes from the target-nanoparticle complex and immobilization and hybridization of the probes for quantification. Herein, we report a novel PCR-free electrochemiluminescence (ECL)-based bio bar code assay for the quantitative detection of genetically modified organism (GMO) from raw materials. It consists of tris-(2,2'-bipyridyl) ruthenium (TBR)-labeled bar code DNA, nucleic acid hybridization using Au-NPs and biotin-labeled probes, and selective capture of the hybridization complex by streptavidin-coated paramagnetic beads. The detection of target DNA is realized by direct measurement of ECL emission of TBR. It can quantitatively detect target nucleic acids with high speed and sensitivity. This method can be used to quantitatively detect GMO fragments from real GMO products.
21 CFR 610.67 - Bar code label requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Bar code label requirements. 610.67 Section 610.67 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS GENERAL BIOLOGICAL PRODUCTS STANDARDS Labeling Standards § 610.67 Bar code label requirements...
21 CFR 610.67 - Bar code label requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Bar code label requirements. 610.67 Section 610.67 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS GENERAL BIOLOGICAL PRODUCTS STANDARDS Labeling Standards § 610.67 Bar code label requirements...
Nuttall, Gregory A; Abenstein, John P; Stubbs, James R; Santrach, Paula; Ereth, Mark H; Johnson, Pamela M; Douglas, Emily; Oliver, William C
2013-04-01
To determine whether the use of a computerized bar code-based blood identification system resulted in a reduction in transfusion errors or near-miss transfusion episodes. Our institution instituted a computerized bar code-based blood identification system in October 2006. After institutional review board approval, we performed a retrospective study of transfusion errors from January 1, 2002, through December 31, 2005, and from January 1, 2007, through December 31, 2010. A total of 388,837 U were transfused during the 2002-2005 period. There were 6 misidentification episodes of a blood product being transfused to the wrong patient during that period (incidence of 1 in 64,806 U or 1.5 per 100,000 transfusions; 95% CI, 0.6-3.3 per 100,000 transfusions). There was 1 reported near-miss transfusion episode (incidence of 0.3 per 100,000 transfusions; 95% CI, <0.1-1.4 per 100,000 transfusions). A total of 304,136 U were transfused during the 2007-2010 period. There was 1 misidentification episode of a blood product transfused to the wrong patient during that period when the blood bag and patient's armband were scanned after starting to transfuse the unit (incidence of 1 in 304,136 U or 0.3 per 100,000 transfusions; 95% CI, <0.1-1.8 per 100,000 transfusions; P=.14). There were 34 reported near-miss transfusion errors (incidence of 11.2 per 100,000 transfusions; 95% CI, 7.7-15.6 per 100,000 transfusions; P<.001). Institution of a computerized bar code-based blood identification system was associated with a large increase in discovered near-miss events. Copyright © 2013 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Objectivity in Grading: The Promise of Bar Codes
ERIC Educational Resources Information Center
Jae, Haeran; Cowling, John
2009-01-01
This article proposes the use of a new technology to assure student anonymity and reduce bias hazards: identifying students by using bar codes. The limited finding suggests that the use of bar codes for assuring student anonymity could potentially cause students to perceive that grades are assigned more fairly and reassure teachers that they are…
Bar Coding the U. S. Government Bill of Lading and the Material Inspection and Receiving Report.
1984-12-01
of respondents K because some of the replies did not respond to this question.) TABLE 3-2. DD 250 PROCESSING CAPABILITIES AUTOMiATED - BAR CODE...Proposed minimum data elements (both human readable and bar coded) required and why? (3) Proposed signature requirement changes and why? (4) Proposed
[Constructing a database that can input record of use and product-specific information].
Kawai, Satoru; Satoh, Kenichi; Yamamoto, Hideo
2012-01-01
In Japan, patients were infected by viral hepatitis C generally by administering a specific fibrinogen injection. However, it has been difficult to identify patients who were infected as result of the injections due to the lack of medical records. It is still not a common practice by a number of medical facilities to maintain detailed information because manual record keeping is extremely time consuming and subject to human error. Due to these reasons, the regulator required Medical device manufacturers and pharmaceutical companies to attach a bar code called "GS1-128" effective March 28, 2008. Based on this new process, we have come up with the idea of constructing a new database whose records can be entered by bar code scanning to ensure data integrity. Upon examining the efficacy of this new data collection process from the perspective of time efficiency and of course data accuracy, "GS1-128" proved that it significantly reduces time and record keeping mistakes. Patients not only became easily identifiable by a lot number and a serial number when immediate care was required, but "GS1-128" enhanced the ability to pinpoint manufacturing errors in the event any trouble or side effects are reported. This data can be shared with and utilized by the entire medical industry and will help perfect the products and enhance record keeping. I believe this new process is extremely important.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-04
... participants with low volumes of deposits have elected to use ``peel-off'' adhesive bar code labels instead of... printers or ``peel-off'' bar code labels. Effective October 8, 2010, DTC retired the outdated and unsupported SNA ticket print stream and the use of ``peel-off'' adhesive bar code labels. Participants...
A Regularization Approach to Blind Deblurring and Denoising of QR Barcodes.
van Gennip, Yves; Athavale, Prashant; Gilles, Jérôme; Choksi, Rustum
2015-09-01
QR bar codes are prototypical images for which part of the image is a priori known (required patterns). Open source bar code readers, such as ZBar, are readily available. We exploit both these facts to provide and assess purely regularization-based methods for blind deblurring of QR bar codes in the presence of noise.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-07
...] Draft Guidance for Industry: Bar Code Label Requirements-- Questions and Answers (Question 12 Update... Administration (FDA) is announcing the availability of a draft document entitled ``Guidance for Industry: Bar... guidance provides you, manufacturers of a licensed vaccine, with advice concerning compliance with the bar...
Optimization education after project implementation: sharing "lessons learned" with staff.
Vaughn, Susan
2011-01-01
Implementations involving healthcare technology solutions focus on providing end-user education prior to the application going "live" in the organization. Benefits to postimplementation education for staff should be included when planning these projects. This author describes the traditional training provided during the implementation of a bar-coding medication project and then the optimization training 8 weeks later.
Morrison, Aileen P; Tanasijevic, Milenko J; Goonan, Ellen M; Lobo, Margaret M; Bates, Michael M; Lipsitz, Stuart R; Bates, David W; Melanson, Stacy E F
2010-06-01
Ensuring accurate patient identification is central to preventing medical errors, but it can be challenging. We implemented a bar code-based positive patient identification system for use in inpatient phlebotomy. A before-after design was used to evaluate the impact of the identification system on the frequency of mislabeled and unlabeled samples reported in our laboratory. Labeling errors fell from 5.45 in 10,000 before implementation to 3.2 in 10,000 afterward (P = .0013). An estimated 108 mislabeling events were prevented by the identification system in 1 year. Furthermore, a workflow step requiring manual preprinting of labels, which was accompanied by potential labeling errors in about one quarter of blood "draws," was removed as a result of the new system. After implementation, a higher percentage of patients reported having their wristband checked before phlebotomy. Bar code technology significantly reduced the rate of specimen identification errors.
2005-03-01
codes speed up consumer shopping, package shipping, and inventory tracking. RFID offers many advantages over bar codes, as the table below shows...sunlight” (Accenture, 2001, p. 4). Finally, one of the most significant advantages of RFID is the advent of anti-collision. Anti-collision allows an...RFID reader to read and/or write to multiple tags at one time, which is not possible for bar codes. Despite the many advantages RFID over bar codes
ERIC Educational Resources Information Center
Crompton, Helen; LaFrance, Jason; van 't Hooft, Mark
2012-01-01
A QR (quick-response) code is a two-dimensional scannable code, similar in function to a traditional bar code that one might find on a product at the supermarket. The main difference between the two is that, while a traditional bar code can hold a maximum of only 20 digits, a QR code can hold up to 7,089 characters, so it can contain much more…
Nanoparticle based bio-bar code technology for trace analysis of aflatoxin B1 in Chinese herbs.
Yu, Yu-Yan; Chen, Yuan-Yuan; Gao, Xuan; Liu, Yuan-Yuan; Zhang, Hong-Yan; Wang, Tong-Ying
2018-04-01
A novel and sensitive assay for aflatoxin B1 (AFB1) detection has been developed by using bio-bar code assay (BCA). The method that relies on polyclonal antibodies encoded with DNA modified gold nanoparticle (NP) and monoclonal antibodies modified magnetic microparticle (MMP), and subsequent detection of amplified target in the form of bio-bar code using a fluorescent quantitative polymerase chain reaction (FQ-PCR) detection method. First, NP probes encoded with DNA that was unique to AFB1, MMP probes with monoclonal antibodies that bind AFB1 specifically were prepared. Then, the MMP-AFB1-NP sandwich compounds were acquired, dehybridization of the oligonucleotides on the nanoparticle surface allows the determination of the presence of AFB1 by identifying the oligonucleotide sequence released from the NP through FQ-PCR detection. The bio-bar code techniques system for detecting AFB1 was established, and the sensitivity limit was about 10 -8 ng/mL, comparable ELISA assays for detecting the same target, it showed that we can detect AFB1 at low attomolar levels with the bio-bar-code amplification approach. This is also the first demonstration of a bio-bar code type assay for the detection of AFB1 in Chinese herbs. Copyright © 2017. Published by Elsevier B.V.
Integrating technology to improve medication administration.
Prusch, Amanda E; Suess, Tina M; Paoletti, Richard D; Olin, Stephen T; Watts, Starann D
2011-05-01
The development, implementation, and evaluation of an i.v. interoperability program to advance medication safety at the bedside are described. I.V. interoperability integrates intelligent infusion devices (IIDs), the bar-code-assisted medication administration system, and the electronic medication administration record system into a bar-code-driven workflow that populates provider-ordered, pharmacist-validated infusion parameters on IIDs. The purpose of this project was to improve medication safety through the integration of these technologies and decrease the potential for error during i.v. medication administration. Four key phases were essential to developing and implementing i.v. interoperability: (a) preparation, (b) i.v. interoperability pilot, (c) preliminary validation, and (d) expansion. The establishment of pharmacy involvement in i.v. interoperability resulted in two additional safety checks: pharmacist infusion rate oversight and nurse independent validation of the autoprogrammed rate. After instituting i.v. interoperability, monthly compliance to the telemetry drug library increased to a mean ± S.D. of 72.1% ± 2.1% from 56.5% ± 1.5%, and the medical-surgical nursing unit's drug library monthly compliance rate increased to 58.6% ± 2.9% from 34.1% ± 2.6% (p < 0.001 for both comparisons). The number of manual pump edits decreased with both telemetry and medical-surgical drug libraries, demonstrating a reduction from 56.9 ± 12.8 to 14.2 ± 3.9 and from 61.2 ± 15.4 to 14.7 ± 3.8, respectively (p < 0.001 for both comparisons). Through the integration and incorporation of pharmacist oversight for rate changes, the telemetry and medical-surgical patient care areas demonstrated a 32% reduction in reported monthly errors involving i.v. administration of heparin. By integrating two stand-alone technologies, i.v. interoperability was implemented to improve medication administration. Medication errors were reduced, nursing workflow was simplified, and pharmacists became involved in checking infusion rates of i.v. medications.
Information technology and medication safety: what is the benefit?
Kaushal, R; Bates, D
2002-01-01
Medication errors occur frequently and have significant clinical and financial consequences. Several types of information technologies can be used to decrease rates of medication errors. Computerized physician order entry with decision support significantly reduces serious inpatient medication error rates in adults. Other available information technologies that may prove effective for inpatients include computerized medication administration records, robots, automated pharmacy systems, bar coding, "smart" intravenous devices, and computerized discharge prescriptions and instructions. In outpatients, computerization of prescribing and patient oriented approaches such as personalized web pages and delivery of web based information may be important. Public and private mandates for information technology interventions are growing, but further development, application, evaluation, and dissemination are required. PMID:12486992
Use the Bar Code System to Improve Accuracy of the Patient and Sample Identification.
Chuang, Shu-Hsia; Yeh, Huy-Pzu; Chi, Kun-Hung; Ku, Hsueh-Chen
2018-01-01
In time and correct sample collection were highly related to patient's safety. The sample error rate was 11.1%, because misbranded patient information and wrong sample containers during January to April, 2016. We developed a barcode system of "Specimens Identify System" through process of reengineering of TRM, used bar code scanners, add sample container instructions, and mobile APP. Conclusion, the bar code systems improved the patient safety and created green environment.
Implementing a bar-coded bedside medication administration system.
Yates, Cindy
2007-01-01
Hospitals across the nation are struggling with implementing electronic medication administration and reporting (eMAR) systems as part of patient safety programs. St Luke's Hospital in Chesterfield, Mo, initiated their eMAR initiative in June 2003, initiating program start-up in September 2004. This case study documents how the project was approached, its overall success, and what was learned along the way. Also included is a recent update highlighting the expansion of St Luke's patient safety initiative, adapting eMAR to two specialty units: dialysis and laboratory processes.
Method and apparatus for reading lased bar codes on shiny-finished fuel rod cladding tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldenfield, M.P.; Lambert, D.V.
1990-10-02
This patent describes, in a nuclear fuel rod identification system, a method of reading a bar code etched directly on a surface of a nuclear fuel rod. It comprises: defining a pair of light diffuser surfaces adjacent one another but in oppositely inclined relation to a beam of light emitted from a light reader; positioning a fuel rod, having a cylindrical surface portion with a bar code etched directly thereon, relative to the light diffuser surfaces such that the surfaces are disposed adjacent to and in oppositely inclined relation along opposite sides of the fuel rod surface portion and themore » fuel rod surface portion is aligned with the beam of light emitted from the light reader; directing the beam of light on the bar code on fuel rod cylindrical surface portion such that the light is reflected therefrom onto one of the light diffuser surfaces; and receiving and reading the reflected light from the bar code via the one of the light diffuser surfaces to the light reader.« less
Biosensors and Bio-Bar Code Assays Based on Biofunctionalized Magnetic Microbeads
Jaffrezic-Renault, Nicole; Martelet, Claude; Chevolot, Yann; Cloarec, Jean-Pierre
2007-01-01
This review paper reports the applications of magnetic microbeads in biosensors and bio-bar code assays. Affinity biosensors are presented through different types of transducing systems: electrochemical, piezo electric or magnetic ones, applied to immunodetection and genodetection. Enzymatic biosensors are based on biofunctionalization through magnetic microbeads of a transducer, more often amperometric, potentiometric or conductimetric. The bio-bar code assays relie on a sandwich structure based on specific biological interaction of a magnetic microbead and a nanoparticle with a defined biological molecule. The magnetic particle allows the separation of the reacted target molecules from unreacted ones. The nanoparticles aim at the amplification and the detection of the target molecule. The bio-bar code assays allow the detection at very low concentration of biological molecules, similar to PCR sensitivity.
19 CFR 142.46 - Presentation of invoice and assignment of entry number.
Code of Federal Regulations, 2011 CFR
2011-04-01
... transportation, the appropriate manifest document. (b) Verification of data. If after scanning the bar code at the Line Release site, the Customs officer verifies the data on the bar code with the information on... assigned to the transaction. If there are any differences between the system data and the invoice and bar...
19 CFR 142.46 - Presentation of invoice and assignment of entry number.
Code of Federal Regulations, 2013 CFR
2013-04-01
... transportation, the appropriate manifest document. (b) Verification of data. If after scanning the bar code at the Line Release site, the Customs officer verifies the data on the bar code with the information on... assigned to the transaction. If there are any differences between the system data and the invoice and bar...
19 CFR 142.46 - Presentation of invoice and assignment of entry number.
Code of Federal Regulations, 2012 CFR
2012-04-01
... transportation, the appropriate manifest document. (b) Verification of data. If after scanning the bar code at the Line Release site, the Customs officer verifies the data on the bar code with the information on... assigned to the transaction. If there are any differences between the system data and the invoice and bar...
19 CFR 142.46 - Presentation of invoice and assignment of entry number.
Code of Federal Regulations, 2014 CFR
2014-04-01
... transportation, the appropriate manifest document. (b) Verification of data. If after scanning the bar code at the Line Release site, the Customs officer verifies the data on the bar code with the information on... assigned to the transaction. If there are any differences between the system data and the invoice and bar...
19 CFR 142.46 - Presentation of invoice and assignment of entry number.
Code of Federal Regulations, 2010 CFR
2010-04-01
... transportation, the appropriate manifest document. (b) Verification of data. If after scanning the bar code at the Line Release site, the Customs officer verifies the data on the bar code with the information on... assigned to the transaction. If there are any differences between the system data and the invoice and bar...
Bar-code medication administration system for anesthetics: effects on documentation and billing.
Nolen, Agatha L; Rodes, W Dyer
2008-04-01
The effects of using a new bar-code medication administration (BCMA) system for anesthetics to automate documentation of drug administration by anesthesiologists were studied. From October 1, 2004, to September 15, 2005, all medications administered to patients undergoing cardiac surgery were documented with a BCMA system at a large acute care facility. Drug claims data for 12 targeted anesthetics in diagnosis-related groups (DRGs) 104-111 were analyzed to determine the quantity of drugs charged and the revenue generated. Those data were compared with claims data for a historical case-control group (October 1, 2003, to September 15, 2004, for the same DRGs) for which medication use was documented manually. From October 1, 2005, to October 1, 2006, anesthesiologists for cardiac surgeries either voluntarily used the automated system or completed anesthesia records manually. A total of 870 cardiac surgery cases for which the BCMA system was used were evaluated. There were 961 cardiac surgery cases in the historical control group. The BCMA system increased the quantity of drugs documented per case by 21.7% and drug revenue captured per case by 18.8%. The time needed by operating-room pharmacy staff to process an anesthesia record for billing decreased by eight minutes per case. After two years, anesthesiologists voluntarily used the new technology on 100% of cardiac surgery patients. Implementation of a BCMA system for anesthetic use in cardiac surgery increased the quantity of drugs charged by 21.7% per case and drug revenue per case by 18.8%. Anesthesiologists continued to use the automated system on a voluntary basis after conclusion of the initial study.
Recycling Expensive Medication: Why Not?
Pomerantz, Jay M
2004-01-01
New (and proposed) advances in packaging, preserving, labeling, and verifying product integrity of individual tablets and capsules may allow for the recycling of certain expensive medicines. Previously sold, but unused, medication, if brought back to special pharmacies for resale or donation, may provide a low-cost source of patent-protected medicines. Benefits of such a program go beyond simply providing affordable medication to the poor. This article suggests that medicine recycling may be a possibility (especially if manufacturers are mandated to blister-package and bar-code individual tablets and capsules). This early discussion of medication recycling identifies relevant issues, such as: need, rationale, existing programs, available supplies, expiration dates, new technology for ensuring safety and potency, environmental impact, public health benefits, program focus, program structure, and liability. PMID:15266231
Laser identification system based on acousto-optical barcode scanner principles
NASA Astrophysics Data System (ADS)
Khansuvarov, Ruslan A.; Korol, Georgy I.; Preslenev, Leonid N.; Bestugin, Aleksandr R.; Paraskun, Arthur S.
2016-09-01
The main purpose of the bar code in the modern world is the unique identification of the product, service, or any of their features, so personal and stationary barcode scanners so widely used. One of the important parameters of bar code scanners is their reliability, accuracy of the barcode recognition, response time and performance. Nowadays, the most popular personal barcode scanners contain a mechanical part, which extremely impairs the reliability indices. Group of SUAI engineers has proposed bar code scanner based on laser beam acoustic deflection effect in crystals [RU patent No 156009 issued 4/16/2015] Through the use of an acousto-optic deflector element in barcode scanner described by a group of engineers SUAI, it can be implemented in the manual form factor, and the stationary form factor of a barcode scanner. Being a wave electronic device, an acousto-optic element in the composition of the acousto-optic barcode scanner allows you to clearly establish a mathematical link between the encoded function of the bar code with the accepted input photodetector intensities function that allows you to speak about the great probability of a bar code clear definition. This paper provides a description of the issued patent, the description of the principles of operation based on the mathematical analysis, a description of the layout of the implemented scanner.
Spirality: A Noval Way to Measure Spiral Arm Pitch Angle
NASA Astrophysics Data System (ADS)
Shields, Douglas W.; Boe, Benjamin; Henderson, Casey L.; Hartley, Matthew; Davis, Benjamin L.; Pour Imani, Hamed; Kennefick, Daniel; Kennefick, Julia D.
2015-01-01
We present the MATLAB code Spirality, a novel method for measuring spiral arm pitch angles by fitting galaxy images to spiral templates of known pitch. For a given pitch angle template, the mean pixel value is found along each of typically 1000 spiral axes. The fitting function, which shows a local maximum at the best-fit pitch angle, is the variance of these means. Error bars are found by varying the inner radius of the measurement annulus and finding the standard deviation of the best-fit pitches. Computation time is typically on the order of 2 minutes per galaxy, assuming at least 8 GB of working memory. We tested the code using 128 synthetic spiral images of known pitch. These spirals varied in the number of spiral arms, pitch angle, degree of logarithmicity, radius, SNR, inclination angle, bar length, and bulge radius. A correct result is defined as a result that matches the true pitch within the error bars, with error bars no greater than ±7°. For the non-logarithmic spiral sample, the correct answer is similarly defined, with the mean pitch as function of radius in place of the true pitch. For all synthetic spirals, correct results were obtained so long as SNR > 0.25, the bar length was no more than 60% of the spiral's diameter (when the bar was included in the measurement), the input center of the spiral was no more than 6% of the spiral radius away from the true center, and the inclination angle was no more than 30°. The synthetic spirals were not deprojected prior to measurement. The code produced the correct result for all barred spirals when the measurement annulus was placed outside the bar. Additionally, we compared the code's results against 2DFFT results for 203 visually selected spiral galaxies in GOODS North and South. Among the entire sample, Spirality's error bars overlapped 2DFFT's error bars 64% of the time. For those galaxies in which Source code is available by email request from the primary author.
Crisis Management- Operational Logistics & Asset Visibility Technologies
2006-06-01
is seen as the successor to today’s bar code technology. However, passive RFID technology has several advantages over bar code technology. First...http://java.sun.com/developer/technicalArticles/ Ecommerce /rfid/ Microsoft. (2006). Hand-held RFID Reader. Retrieved May 11, 2006, from http
Review of Punching Shear Behaviour of Flat Slabs Reinforced with FRP Bars
NASA Astrophysics Data System (ADS)
Mohamed, Osama A.; Khattab, Rania
2017-10-01
Using Fibre Reinforced Polymer (FRP) bars to reinforce two-way concrete slabs can extend the service life, reduce maintenance cost and improve-life cycle cost efficiency. FRP reinforcing bars are more environmentally friendly alternatives to traditional reinforcing steel. Shear behaviour of reinforced concrete structural members is a complex phenomenon that relies on the development of internal load-carrying mechanisms, the magnitude and combination of which is still a subject of research. Many building codes and design standards provide design formulas for estimation of punching shear capacity of FRP reinforced flat slabs. Building code formulas take into account the effects of the axial stiffness of main reinforcement bars, the ratio of the perimeter of the critical section to the slab effective depth, and the slab thickness on the punching shear capacity of two-way slabs reinforced with FRP bars or grids. The goal of this paper is to compare experimental data published in the literature to the equations offered by building codes for the estimation of punching shear capacity of concrete flat slabs reinforced with FRP bars. Emphasis in this paper is on two North American codes, namely, ACI 440.1R-15 and CSA S806-12. The experimental data covered in this paper include flat slabs reinforced with GFRP, BFRP, and CFRP bars. Both ACI 440.1R-15 and CSA S806-12 are shown to be in good agreement with test results in terms of predicting the punching shear capacity.
Holden, Richard J; Rivera-Rodriguez, A Joy; Faye, Héléne; Scanlon, Matthew C; Karsh, Ben-Tzion
2013-08-01
The most common change facing nurses today is new technology, particularly bar coded medication administration technology (BCMA). However, there is a dearth of knowledge on how BCMA alters nursing work. This study investigated how BCMA technology affected nursing work, particularly nurses' operational problem-solving behavior. Cognitive systems engineering observations and interviews were conducted after the implementation of BCMA in three nursing units of a freestanding pediatric hospital. Problem-solving behavior, associated problems, and goals, were specifically defined and extracted from observed episodes of care. Three broad themes regarding BCMA's impact on problem solving were identified. First, BCMA allowed nurses to invent new problem-solving behavior to deal with pre-existing problems. Second, BCMA made it difficult or impossible to apply some problem-solving behaviors that were commonly used pre-BCMA, often requiring nurses to use potentially risky workarounds to achieve their goals. Third, BCMA created new problems that nurses were either able to solve using familiar or novel problem-solving behaviors, or unable to solve effectively. Results from this study shed light on hidden hazards and suggest three critical design needs: (1) ecologically valid design; (2) anticipatory control; and (3) basic usability. Principled studies of the actual nature of clinicians' work, including problem solving, are necessary to uncover hidden hazards and to inform health information technology design and redesign.
Holden, Richard J.; Rivera-Rodriguez, A. Joy; Faye, Héléne; Scanlon, Matthew C.; Karsh, Ben-Tzion
2012-01-01
The most common change facing nurses today is new technology, particularly bar coded medication administration technology (BCMA). However, there is a dearth of knowledge on how BCMA alters nursing work. This study investigated how BCMA technology affected nursing work, particularly nurses’ operational problem-solving behavior. Cognitive systems engineering observations and interviews were conducted after the implementation of BCMA in three nursing units of a freestanding pediatric hospital. Problem-solving behavior, associated problems, and goals, were specifically defined and extracted from observed episodes of care. Three broad themes regarding BCMA’s impact on problem solving were identified. First, BCMA allowed nurses to invent new problem-solving behavior to deal with pre-existing problems. Second, BCMA made it difficult or impossible to apply some problem-solving behaviors that were commonly used pre-BCMA, often requiring nurses to use potentially risky workarounds to achieve their goals. Third, BCMA created new problems that nurses were either able to solve using familiar or novel problem-solving behaviors, or unable to solve effectively. Results from this study shed light on hidden hazards and suggest three critical design needs: (1) ecologically valid design; (2) anticipatory control; and (3) basic usability. Principled studies of the actual nature of clinicians’ work, including problem solving, are necessary to uncover hidden hazards and to inform health information technology design and redesign. PMID:24443642
Bar code-based pre-transfusion check in pre-operative autologous blood donation.
Ohsaka, Akimichi; Furuta, Yoshiaki; Ohsawa, Toshiya; Kobayashi, Mitsue; Abe, Katsumi; Inada, Eiichi
2010-10-01
The objective of this study was to demonstrate the feasibility of a bar code-based identification system for the pre-transfusion check at the bedside in the setting of pre-operative autologous blood donation (PABD). Between July 2003 and December 2008 we determined the compliance rate and causes of failure of electronic bedside checking for PABD transfusion. A total of 5627 (9% of all transfusions) PABD units were administered without a single mistransfusion. The overall rate of compliance with electronic checking was 99%. The bar code-based identification system was applicable to the pre-transfusion check for PABD transfusion. Copyright © 2010 Elsevier Ltd. All rights reserved.
Poon, Eric G; Cina, Jennifer L; Churchill, William W; Mitton, Patricia; McCrea, Michelle L; Featherstone, Erica; Keohane, Carol A; Rothschild, Jeffrey M; Bates, David W; Gandhi, Tejal K
2005-01-01
We performed a direct observation pre-post study to evaluate the impact of barcode technology on medication dispensing errors and potential adverse drug events in the pharmacy of a tertiary-academic medical center. We found that barcode technology significantly reduced the rate of target dispensing errors leaving the pharmacy by 85%, from 0.37% to 0.06%. The rate of potential adverse drug events (ADEs) due to dispensing errors was also significantly reduced by 63%, from 0.19% to 0.069%. In a 735-bed hospital where 6 million doses of medications are dispensed per year, this technology is expected to prevent about 13,000 dispensing errors and 6,000 potential ADEs per year. PMID:16779372
All You Need to Know about Videodiscs: One Easy Lesson.
ERIC Educational Resources Information Center
Padgett, Helen L.
1993-01-01
Explains videodisc technology and its uses in education. Topics addressed include formats of videodiscs, including CAV discs (constant angular velocity) and CLV discs (constant linear velocity); the three industry-standard levels of interactivity; bar codes; bar-code readers; and finding information on a videodisc. (LRW)
Robotic automation of medication-use management.
Enright, S M
1993-11-01
In the October 1993 issue of Physician Assistant, we published "Robots for Health Care," the first of two articles on the medical applications of robotics. That article discussed ways in which robots could help patients with manipulative disabilities to perform activities of daily living and hold paid employment; transfer patients from bed to chair and back again; add precision to the most exacting surgical procedures; and someday carry out diagnostic and therapeutic techniques from within the human body. This month, we are pleased to offer an article by Sharon Enright, an authority on pharmacy operations, who considers how an automated medication-management system that makes use of bar-code technology is capable of streamlining drug dispensing, controlling safety, increasing cost-effectiveness, and ensuring accurate and complete record-keeping.
21 CFR 201.25 - Bar code label requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... and Research, Food and Drug Administration, 10903 New Hampshire Ave., Bldg. 51, Silver Spring, MD...-600), Center for Biologics Evaluation and Research, Food and Drug Administration, 1401 Rockville Pike... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Bar code label requirements. 201.25 Section 201.25...
21 CFR 201.25 - Bar code label requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Evaluation and Research, Food and Drug Administration, 5600 Fishers Lane, Rockville, MD 20857 (requests... Biologics Evaluation and Research, Food and Drug Administration, 1401 Rockville Pike, Rockville, MD 20852... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Bar code label requirements. 201.25 Section 201.25...
Wetmore, Kelly M.; Price, Morgan N.; Waters, Robert J.; ...
2015-05-12
Transposon mutagenesis with next-generation sequencing (TnSeq) is a powerful approach to annotate gene function in bacteria, but existing protocols for TnSeq require laborious preparation of every sample before sequencing. Thus, the existing protocols are not amenable to the throughput necessary to identify phenotypes and functions for the majority of genes in diverse bacteria. Here, we present a method, random bar code transposon-site sequencing (RB-TnSeq), which increases the throughput of mutant fitness profiling by incorporating random DNA bar codes into Tn5 and mariner transposons and by using bar code sequencing (BarSeq) to assay mutant fitness. RB-TnSeq can be used with anymore » transposon, and TnSeq is performed once per organism instead of once per sample. Each BarSeq assay requires only a simple PCR, and 48 to 96 samples can be sequenced on one lane of an Illumina HiSeq system. We demonstrate the reproducibility and biological significance of RB-TnSeq with Escherichia coli, Phaeobacter inhibens, Pseudomonas stutzeri, Shewanella amazonensis, and Shewanella oneidensis. To demonstrate the increased throughput of RB-TnSeq, we performed 387 successful genome-wide mutant fitness assays representing 130 different bacterium-carbon source combinations and identified 5,196 genes with significant phenotypes across the five bacteria. In P. inhibens, we used our mutant fitness data to identify genes important for the utilization of diverse carbon substrates, including a putative D-mannose isomerase that is required for mannitol catabolism. RB-TnSeq will enable the cost-effective functional annotation of diverse bacteria using mutant fitness profiling. A large challenge in microbiology is the functional assessment of the millions of uncharacterized genes identified by genome sequencing. Transposon mutagenesis coupled to next-generation sequencing (TnSeq) is a powerful approach to assign phenotypes and functions to genes. However, the current strategies for TnSeq are too laborious to be applied to hundreds of experimental conditions across multiple bacteria. Here, we describe an approach, random bar code transposon-site sequencing (RB-TnSeq), which greatly simplifies the measurement of gene fitness by using bar code sequencing (BarSeq) to monitor the abundance of mutants. We performed 387 genome-wide fitness assays across five bacteria and identified phenotypes for over 5,000 genes. RB-TnSeq can be applied to diverse bacteria and is a powerful tool to annotate uncharacterized genes using phenotype data.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wetmore, Kelly M.; Price, Morgan N.; Waters, Robert J.
Transposon mutagenesis with next-generation sequencing (TnSeq) is a powerful approach to annotate gene function in bacteria, but existing protocols for TnSeq require laborious preparation of every sample before sequencing. Thus, the existing protocols are not amenable to the throughput necessary to identify phenotypes and functions for the majority of genes in diverse bacteria. Here, we present a method, random bar code transposon-site sequencing (RB-TnSeq), which increases the throughput of mutant fitness profiling by incorporating random DNA bar codes into Tn5 and mariner transposons and by using bar code sequencing (BarSeq) to assay mutant fitness. RB-TnSeq can be used with anymore » transposon, and TnSeq is performed once per organism instead of once per sample. Each BarSeq assay requires only a simple PCR, and 48 to 96 samples can be sequenced on one lane of an Illumina HiSeq system. We demonstrate the reproducibility and biological significance of RB-TnSeq with Escherichia coli, Phaeobacter inhibens, Pseudomonas stutzeri, Shewanella amazonensis, and Shewanella oneidensis. To demonstrate the increased throughput of RB-TnSeq, we performed 387 successful genome-wide mutant fitness assays representing 130 different bacterium-carbon source combinations and identified 5,196 genes with significant phenotypes across the five bacteria. In P. inhibens, we used our mutant fitness data to identify genes important for the utilization of diverse carbon substrates, including a putative D-mannose isomerase that is required for mannitol catabolism. RB-TnSeq will enable the cost-effective functional annotation of diverse bacteria using mutant fitness profiling. A large challenge in microbiology is the functional assessment of the millions of uncharacterized genes identified by genome sequencing. Transposon mutagenesis coupled to next-generation sequencing (TnSeq) is a powerful approach to assign phenotypes and functions to genes. However, the current strategies for TnSeq are too laborious to be applied to hundreds of experimental conditions across multiple bacteria. Here, we describe an approach, random bar code transposon-site sequencing (RB-TnSeq), which greatly simplifies the measurement of gene fitness by using bar code sequencing (BarSeq) to monitor the abundance of mutants. We performed 387 genome-wide fitness assays across five bacteria and identified phenotypes for over 5,000 genes. RB-TnSeq can be applied to diverse bacteria and is a powerful tool to annotate uncharacterized genes using phenotype data.« less
Holden, Richard J.; Brown, Roger L.; Scanlon, Matthew C.; Karsh, Ben-Tzion
2012-01-01
Background The safety benefits of bar-coded medication dispensing and administration technology (BCMA) depend on its intended users favorably perceiving, accepting, and ultimately using the technology. Objectives (1) To describe pharmacy workers’ perceptions and acceptance of a recently implemented BCMA system and (2) to model the relationship between perceptions and acceptance of BCMA. Methods Pharmacists and pharmacy technicians at a Midwest US pediatric hospital were surveyed following the hospital’s implementation of a BCMA system. Twenty-nine pharmacists and ten technicians’ self-reported perceptions and acceptance of the BCMA system were analyzed, supplemented by qualitative observational and free-response survey data. Perception-acceptance associations were analyzed using structural models. Results The BCMA system’s perceived ease of use was rated low by pharmacists and moderate by pharmacy technicians. Both pharmacists and technicians perceived that the BCMA system was not useful for improving either personal job performance or patient care. Pharmacy workers perceived that individuals important to them encouraged BMCA use. Pharmacy workers generally intended to use BCMA but reported low satisfaction with the system. Perceptions explained 72% of the variance in intention to use BCMA and 79% of variance in satisfaction with BCMA. Conclusions To promote their acceptance and use, BCMA and other technologies must be better designed and integrated into the clinical work system. Key steps to achieving better design and integration include measuring clinicians’ acceptance and elucidating perceptions and other factors that shape acceptance. PMID:22417887
Holden, Richard J; Brown, Roger L; Scanlon, Matthew C; Karsh, Ben-Tzion
2012-01-01
The safety benefits of bar-coded medication-dispensing and administration (BCMA) technology depend on its intended users favorably perceiving, accepting, and ultimately using the technology. (1) To describe pharmacy workers' perceptions and acceptance of a recently implemented BCMA system and (2) to model the relationship between perceptions and acceptance of BCMA. Pharmacists and pharmacy technicians at a Midwest U.S. pediatric hospital were surveyed following the hospital's implementation of a BCMA system. Twenty-nine pharmacists' and 10 technicians' self-reported perceptions and acceptance of the BCMA system were analyzed, supplemented by qualitative observational and free-response survey data. Perception-acceptance associations were analyzed using structural models. The BCMA system's perceived ease of use was rated low by pharmacists and moderate by pharmacy technicians. Both pharmacists and technicians perceived that the BCMA system was not useful for improving either personal job performance or patient care. Pharmacy workers perceived that individuals important to them encouraged BMCA use. Pharmacy workers generally intended to use BCMA but reported low satisfaction with the system. Perceptions explained 72% of the variance in intention to use BCMA and 79% of variance in satisfaction with BCMA. To promote their acceptance and use, BCMA and other technologies must be better designed and integrated into the clinical work system. Key steps to achieving better design and integration include measuring clinicians' acceptance and elucidating perceptions and other factors that shape acceptance. Copyright © 2012 Elsevier Inc. All rights reserved.
Wetmore, Kelly M.; Price, Morgan N.; Waters, Robert J.; Lamson, Jacob S.; He, Jennifer; Hoover, Cindi A.; Blow, Matthew J.; Bristow, James; Butland, Gareth
2015-01-01
ABSTRACT Transposon mutagenesis with next-generation sequencing (TnSeq) is a powerful approach to annotate gene function in bacteria, but existing protocols for TnSeq require laborious preparation of every sample before sequencing. Thus, the existing protocols are not amenable to the throughput necessary to identify phenotypes and functions for the majority of genes in diverse bacteria. Here, we present a method, random bar code transposon-site sequencing (RB-TnSeq), which increases the throughput of mutant fitness profiling by incorporating random DNA bar codes into Tn5 and mariner transposons and by using bar code sequencing (BarSeq) to assay mutant fitness. RB-TnSeq can be used with any transposon, and TnSeq is performed once per organism instead of once per sample. Each BarSeq assay requires only a simple PCR, and 48 to 96 samples can be sequenced on one lane of an Illumina HiSeq system. We demonstrate the reproducibility and biological significance of RB-TnSeq with Escherichia coli, Phaeobacter inhibens, Pseudomonas stutzeri, Shewanella amazonensis, and Shewanella oneidensis. To demonstrate the increased throughput of RB-TnSeq, we performed 387 successful genome-wide mutant fitness assays representing 130 different bacterium-carbon source combinations and identified 5,196 genes with significant phenotypes across the five bacteria. In P. inhibens, we used our mutant fitness data to identify genes important for the utilization of diverse carbon substrates, including a putative d-mannose isomerase that is required for mannitol catabolism. RB-TnSeq will enable the cost-effective functional annotation of diverse bacteria using mutant fitness profiling. PMID:25968644
Improving radiopharmaceutical supply chain safety by implementing bar code technology.
Matanza, David; Hallouard, François; Rioufol, Catherine; Fessi, Hatem; Fraysse, Marc
2014-11-01
The aim of this study was to describe and evaluate an approach for improving radiopharmaceutical supply chain safety by implementing bar code technology. We first evaluated the current situation of our radiopharmaceutical supply chain and, by means of the ALARM protocol, analysed two dispensing errors that occurred in our department. Thereafter, we implemented a bar code system to secure selected key stages of the radiopharmaceutical supply chain. Finally, we evaluated the cost of this implementation, from overtime, to overheads, to additional radiation exposure to workers. An analysis of the events that occurred revealed a lack of identification of prepared or dispensed drugs. Moreover, the evaluation of the current radiopharmaceutical supply chain showed that the dispensation and injection steps needed to be further secured. The bar code system was used to reinforce product identification at three selected key stages: at usable stock entry; at preparation-dispensation; and during administration, allowing to check conformity between the labelling of the delivered product (identity and activity) and the prescription. The extra time needed for all these steps had no impact on the number and successful conduct of examinations. The investment cost was reduced (2600 euros for new material and 30 euros a year for additional supplies) because of pre-existing computing equipment. With regard to the radiation exposure to workers there was an insignificant overexposure for hands with this new organization because of the labelling and scanning processes of radiolabelled preparation vials. Implementation of bar code technology is now an essential part of a global securing approach towards optimum patient management.
Student and staff opinion of electronic capture of data related to clinical activity.
Oliver, R G
1997-02-01
To seek the opinion of staff and students of a new electronic method for collection of data related to student clinical activity. Questionnaire survey. Staff and students in the Department of Child Dental Health, Dental School, Cardiff, and staff in the Community Dental Service who undertake clinical supervision. A questionnaire was circulated to all 2nd and 3rd clinical year dental undergraduate students seeking their opinion on a range of issues associated with the recently introduced bar code system of data gathering of their clinical activity and achievement. A similar questionnaire was circulated to staff who have responsibility for clinical supervision of these students. A total of 102 replies were received. With the exception of 2 aspects, there was no disagreement between staff and students. An overall majority preferred the use of bar codes to other methods of data collection; bar codes were perceived to be more accurate and reliable than other methods; students were satisfied with the method of quality assessment; staff were dissatisfied (P < 0.05). Staff were strongly in favour of extension of the use of bar codes to other clinics, whereas students were less strongly in favour (P < 0.001); there was little enthusiasm to extend bar codes for recording attendance at lectures, seminars and other such activity. The new system has been accepted by staff and students alike. It has proven to be satisfactory for its intended purpose. As a result of this survey, minor adjustments to procedures will take place, and the method of assessment of clinical work will be reconsidered.
Changes in Smoking-Related Norms in Bars Resulting from California's Smoke-Free Workplace Act
ERIC Educational Resources Information Center
Satterlund, Travis D.; Lee, Juliet P.; Moore, Roland S.
2012-01-01
California's Smoke-Free Workplace Act--CA Labor Code Sec. 6404.5(a)--was extended to bars in 1998. This article analyzes changes in normative beliefs and behaviors related to bar smoking in the decade following the adoption of the Act. In a series of studies evaluating the smoke-free workplace law in bars, researchers conducted extensive…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-26
... costs and benefits of the rule and to identify any relevant changes in technology that have occurred... access to care; Whether the public health benefits of an action have been realized; Whether the public or... reviewing under E.O. 13563 is the Bar Code Final Rule. The Agency plans to reassess its costs and benefits...
Mair, Christina; Gruenewald, Paul J; Ponicki, William R; Remer, Lillian
2013-01-01
Groups of potentially violent drinkers may frequent areas of communities with large numbers of alcohol outlets, especially bars, leading to greater rates of alcohol-related assaults. This study assessed direct and moderating effects of bar densities on assaults across neighborhoods. We analyzed longitudinal population data relating alcohol outlet densities (total outlet density, proportion bars/pubs, proportion off-premise outlets) to hospitalizations for assault injuries in California across residential ZIP code areas from 1995 through 2008 (23,213 space-time units). Because few ZIP codes were consistently defined over 14 years and these units are not independent, corrections for unit misalignment and spatial autocorrelation were implemented using Bayesian space-time conditional autoregressive models. Assaults were related to outlet densities in local and surrounding areas, the mix of outlet types, and neighborhood characteristics. The addition of one outlet per square mile was related to a small 0.23% increase in assaults. A 10% greater proportion of bars in a ZIP code was related to 7.5% greater assaults, whereas a 10% greater proportion of bars in surrounding areas was related to 6.2% greater assaults. The impacts of bars were much greater in areas with low incomes and dense populations. The effect of bar density on assault injuries was well supported and positive, and the magnitude of the effect varied by neighborhood characteristics. Posterior distributions from these models enabled the identification of locations most vulnerable to problems related to alcohol outlets.
Uy, Raymonde Charles Y; Kury, Fabricio P; Fontelo, Paul A
2015-01-01
The standard of safe medication practice requires strict observance of the five rights of medication administration: the right patient, drug, time, dose, and route. Despite adherence to these guidelines, medication errors remain a public health concern that has generated health policies and hospital processes that leverage automation and computerization to reduce these errors. Bar code, RFID, biometrics and pharmacy automation technologies have been demonstrated in literature to decrease the incidence of medication errors by minimizing human factors involved in the process. Despite evidence suggesting the effectivity of these technologies, adoption rates and trends vary across hospital systems. The objective of study is to examine the state and adoption trends of automatic identification and data capture (AIDC) methods and pharmacy automation technologies in U.S. hospitals. A retrospective descriptive analysis of survey data from the HIMSS Analytics® Database was done, demonstrating an optimistic growth in the adoption of these patient safety solutions.
Error-Detecting Identification Codes for Algebra Students.
ERIC Educational Resources Information Center
Sutherland, David C.
1990-01-01
Discusses common error-detecting identification codes using linear algebra terminology to provide an interesting application of algebra. Presents examples from the International Standard Book Number, the Universal Product Code, bank identification numbers, and the ZIP code bar code. (YP)
Numerical modeling of barred spiral galaxies
NASA Astrophysics Data System (ADS)
Moore, Elizabeth Mary
1992-08-01
A two-component, self-consistent computer code to model spiral galaxies was written and tested and a method of inducing and controlling bar formation is developed. This work presents a departure from former modeling work done at the University of Florida, which depended on the beam scheme, a hydrodynamical code with a number of limitations. In particular, only the gas component could be modeled, no self-gravitational forces were included, and the viscosity inherent to the code could not be controlled easily. These shortcomings are overcome in the new algorithm. Most importantly, an attempt has been made to keep the models self-consistent. No perturbing potentials are imposed or required to excite bar and spiral structure. The code can model both the stellar and the gaseous component of a spiral galaxy. The stellar component feels only gravitational forces, while the gas component feels both gravitational and viscous forces. In addition, a halo force can be imposed for the purpose of stabilizing the disk. The code is a hybrid grid/smooth particle code. The gravitational forces are calculated on a Cartesian grid using a Fast Fourier Transform, while the gas viscous forces are calculated in a smooth particle manner. A mechanism for creating warm, featureless, stable disks is developed by taking moments of the collision less Boltzmann equation. In order to induce and control bar and spiral arm formation, the stabilizing stellar velocity dispersions are reduced in the center of the disk, but maintained in the outer regions. A bar forms naturally in the interior and the rotation of this bar helps maintain spiral structure in the outer gas disk. Realistic-looking spiral features are maintained in the gas component for as long as the models are calculated. A wide variety of bar and spiral structure can be formed by varying the size of the unstable central region, the rate of 'turn on', of the heating and the halo mass. We would like to test the model results by comparing them with observations and so a second part of the thesis consists of observing and reducing 21 cm line data of NGC 1398 and NGC 1784 at the Very Large Array. Low (C/D array) and high (B/C) resolution data were obtained, calibrated and combined to make maps of the integrated column density and mean radial velocity of the neutral hydrogen.
A Model for Predicting Thermomechanical Response of Large Space Structures.
1985-06-01
Field in a Thermomechanically Heated Viscoplastic ....... Space Truss Structure 6.5 Analysis of a Thermoviscoplastic Uniaxial " Bar Under Prescribed...Stress Part I - Theoretical Development . -- 6.6 Analysis of a Thermoviscoplastic Uniaxial codes Bar Under Prescribed Stress Part II - or Boundary Layer...and Asymptotic Analysis 6.7 Analysis of a Thermoviscoplastic Uniaxial Bar Under Prescribed Stress Part III - Numerical Results for a Bar with Radiative
Technology and medication errors: impact in nursing homes.
Baril, Chantal; Gascon, Viviane; St-Pierre, Liette; Lagacé, Denis
2014-01-01
The purpose of this paper is to study a medication distribution technology's (MDT) impact on medication errors reported in public nursing homes in Québec Province. The work was carried out in six nursing homes (800 patients). Medication error data were collected from nursing staff through a voluntary reporting process before and after MDT was implemented. The errors were analysed using: totals errors; medication error type; severity and patient consequences. A statistical analysis verified whether there was a significant difference between the variables before and after introducing MDT. The results show that the MDT detected medication errors. The authors' analysis also indicates that errors are detected more rapidly resulting in less severe consequences for patients. MDT is a step towards safer and more efficient medication processes. Our findings should convince healthcare administrators to implement technology such as electronic prescriber or bar code medication administration systems to improve medication processes and to provide better healthcare to patients. Few studies have been carried out in long-term healthcare facilities such as nursing homes. The authors' study extends what is known about MDT's impact on medication errors in nursing homes.
Hakala, John L; Hung, Joseph C; Mosman, Elton A
2012-09-01
The objective of this project was to ensure correct radiopharmaceutical administration through the use of a bar code system that links patient and drug profiles with on-site information management systems. This new combined system would minimize the amount of manual human manipulation, which has proven to be a primary source of error. The most common reason for dosing errors is improper patient identification when a dose is obtained from the nuclear pharmacy or when a dose is administered. A standardized electronic transfer of information from radiopharmaceutical preparation to injection will further reduce the risk of misadministration. Value stream maps showing the flow of the patient dose information, as well as potential points of human error, were developed. Next, a future-state map was created that included proposed corrections for the most common critical sites of error. Transitioning the current process to the future state will require solutions that address these sites. To optimize the future-state process, a bar code system that links the on-site radiology management system with the nuclear pharmacy management system was proposed. A bar-coded wristband connects the patient directly to the electronic information systems. The bar code-enhanced process linking the patient dose with the electronic information reduces the number of crucial points for human error and provides a framework to ensure that the prepared dose reaches the correct patient. Although the proposed flowchart is designed for a site with an in-house central nuclear pharmacy, much of the framework could be applied by nuclear medicine facilities using unit doses. An electronic connection between information management systems to allow the tracking of a radiopharmaceutical from preparation to administration can be a useful tool in preventing the mistakes that are an unfortunate reality for any facility.
Liability for medical malpractice--recent New Zealand developments.
Sladden, Nicola; Graydon, Sarah
2009-03-01
Over the last 30 years in New Zealand, civil liability for personal injury including "medical malpractice" has been most notable for its absence. The system of accident compensation and the corresponding bar on personal injury claims has been an interesting contrast to the development of tort law claims for personal injury in other jurisdictions. The Health and Disability Commissioner was appointed in 1994 to protect and promote the rights of health and disability consumers as set out in the Code of Health and Disability Services Consumers' Rights. An important right in the Code, in terms of an equivalent to the common law duty to take reasonable care, is that patients have the right to services of an appropriate standard. Several case studies from the Commissioner's Office are used to illustrate New Zealand's unique medico-legal system and demonstrate how the traditional common law obligation of reasonable care and skill is applied. From an international perspective, the most interesting aspect of liability for medical malpractice in New Zealand is its relative absence - in a tortious sense anyway. This paper will give some general background on the New Zealand legal landscape and discuss recent case studies of interest.
Shida, Kyoko; Suzuki, Toshiyasu; Sugahara, Kazuhiro; Sobue, Kazuya
2016-05-01
In the case of medication errors which are among the more frequent adverse events that occur in the hospital, there is a need for effective measures to prevent incidence. According to the Japan Society of Anesthesiologists study "Drug incident investigation 2005-2007 years", "Error of a syringe at the selection stage" was the most frequent (44.2%). The status of current measures and best practices implemented in Japanese hospitals was the focus of a subsequent investigation. Representative specialists in anesthesiology certified hospitals across the country were surveyed via a questionnaire sampling that lasted 46 days. Investigation method was via the Web with survey responses anonymous. With respect to preventive measures implemented to mitigate risk of medication errors in perioperative settings, responses included: incident and accident report (215 facilities, 70.3%), use of pre-filled syringes (180 facilities, 58.8%), devised the arrangement of dangerous drugs (154 facilities, 50.3%), use of the product with improper connection preventing mechanism (123 facilities, 40.2%), double-check (116 facilities, 37.9%), use of color barreled syringe (115 facilities, 37.6%), use of color label or color tape (89 facilities, 29.1%), presentation of medication such as placing the ampoule or syringe on a tray by dividing color code for drug class on a tray (54 facilities, 17.6%), the discontinuance of handwritten labels (23 facilities, 7.5%), use of a drug verification system that uses bar code (20 facilities, 6.5%), and facilities that have not implemented any means (11 facilities, 3.6%), others not mentioned (10 facilities, 3.3%), and use of carts that count/account the agents by drug type and record selection and number picked automatically (6 facilities, 2.0%). Drug name identification affixed to the syringe via perforated label torn from the ampoule/vial, etc. (245 facilities, 28.1%), handwriting directly to the syringe (208 facilities, 23.8%), use of the attached label (like that comes with the product) (187 facilities, 21.4%), handwriting on the plain tape (87 facilities, 10.0%), printing labels (62 facilities, 7.1%), printed color labels (44 facilities, 5.0%), handwriting on the color tape (27 facilities, 3.1%), machinery for printing the drug name by scanning bar code of the ampoule, etc.(10 facilities, 1.1%), others (3 facilities, 0.3%), no description on the prepared drug (0 facilities, 0%). The awareness of international standard color code, such as by the International Organization for Standardization (ISO), was only 18.6%. Targeting anesthesiology certified hospitals recognized by the Japan Society of Anesthesiologists, the result of the survey on the measures to prevent medication errors during perioperative procedures indicated that various measures were documented in use. However, many facilities still use hand written labels (a common cause for errors). Confirmation of the need for improved drug name and drug recognition on syringe was documented.
Thin family: a new barcode concept
NASA Astrophysics Data System (ADS)
Allais, David C.
1991-02-01
This paper describes a new space-efficient family of thin bar code symbologies which are appropriate for representing small amounts of information. The proposed structure is 30 to 50 percent more compact than the narrowest existing bar code when 12 or fewer bits of information are to be encoded in each symbol. Potential applications for these symbologies include menus catalogs automated test and survey scoring and biological research such as the tracking of honey bees.
Modeling And Simulation Of Bar Code Scanners Using Computer Aided Design Software
NASA Astrophysics Data System (ADS)
Hellekson, Ron; Campbell, Scott
1988-06-01
Many optical systems have demanding requirements to package the system in a small 3 dimensional space. The use of computer graphic tools can be a tremendous aid to the designer in analyzing the optical problems created by smaller and less costly systems. The Spectra Physics grocery store bar code scanner employs an especially complex 3 dimensional scan pattern to read bar code labels. By using a specially written program which interfaces with a computer aided design system, we have simulated many of the functions of this complex optical system. In this paper we will illustrate how a recent version of the scanner has been designed. We will discuss the use of computer graphics in the design process including interactive tweaking of the scan pattern, analysis of collected light, analysis of the scan pattern density, and analysis of the manufacturing tolerances used to build the scanner.
Patient safety with blood products administration using wireless and bar-code technology.
Porcella, Aleta; Walker, Kristy
2005-01-01
Supported by a grant from the Agency for Healthcare Research and Quality, a University of Iowa Hospitals and Clinics interdisciplinary research team created an online data-capture-response tool utilizing wireless mobile devices and bar code technology to track and improve blood products administration process. The tool captures 1) sample collection, 2) sample arrival in the blood bank, 3) blood product dispense from blood bank, and 4) administration. At each step, the scanned patient wristband ID bar code is automatically compared to scanned identification barcode on requisition, sample, and/or product, and the system presents either a confirmation or an error message to the user. Following an eight-month, 5 unit, staged pilot, a 'big bang,' hospital-wide implementation occurred on February 7, 2005. Preliminary results from pilot data indicate that the new barcode process captures errors 3 to 10 times better than the old manual process.
Use of bar coding technology to flag ER patients on metformin-containing drugs.
Lipcamon, James D; Miller, Pam; Kaiser, Tom; Campbell, Bonnie; Freemen, Amanda
2009-01-01
Sixty percent of Jennie Edmundson Hospital's inpatients are admitted through the emergency room. Type II diabetes accounts for 90-95% of all diagnosed cases of diabetes. There were about 1.6 million new cases of diabetes diagnosed in people 20 years or older in 2007. Consequently, we should expect to see an increase in Americans on metformin-containing drugs in the future. Jennie Edmundson Hospital's goal was to develop a hardwired process to identify patients on the medication metformin and who had a CT scan with contrast in the ER and were then admitted as an inpatient.
1994-09-01
650 B.C. in Asia Minor, coins were developed and used in acquiring goods and services. In France, during the eighteenth century, paper money made its... counterfeited . [INFO94, p. 23] Other weaknesses of bar code technology include limited data storage capability based on the bar code symbology used when...extremely accurate, with calculated error rates as low as 1 in 100 trillion, and are difficult to counterfeit . Strong magnetic fields cannot erase RF
Bar coded retroreflective target
Vann, Charles S.
2000-01-01
This small, inexpensive, non-contact laser sensor can detect the location of a retroreflective target in a relatively large volume and up to six degrees of position. The tracker's laser beam is formed into a plane of light which is swept across the space of interest. When the beam illuminates the retroreflector, some of the light returns to the tracker. The intensity, angle, and time of the return beam is measured to calculate the three dimensional location of the target. With three retroreflectors on the target, the locations of three points on the target are measured, enabling the calculation of all six degrees of target position. Until now, devices for three-dimensional tracking of objects in a large volume have been heavy, large, and very expensive. Because of the simplicity and unique characteristics of this tracker, it is capable of three-dimensional tracking of one to several objects in a large volume, yet it is compact, light-weight, and relatively inexpensive. Alternatively, a tracker produces a diverging laser beam which is directed towards a fixed position, and senses when a retroreflective target enters the fixed field of view. An optically bar coded target can be read by the tracker to provide information about the target. The target can be formed of a ball lens with a bar code on one end. As the target moves through the field, the ball lens causes the laser beam to scan across the bar code.
Computations of Axisymmetric Flows in Hypersonic Shock Tubes
NASA Technical Reports Server (NTRS)
Sharma, Surendra P.; Wilson, Gregory J.
1995-01-01
A time-accurate two-dimensional fluid code is used to compute test times in shock tubes operated at supersonic speeds. Unlike previous studies, this investigation resolves the finer temporal details of the shock-tube flow by making use of modern supercomputers and state-of-the-art computational fluid dynamic solution techniques. The code, besides solving the time-dependent fluid equations, also accounts for the finite rate chemistry in the hypersonic environment. The flowfield solutions are used to estimate relevant shock-tube parameters for laminar flow, such as test times, and to predict density and velocity profiles. Boundary-layer parameters such as bar-delta(sub u), bar-delta(sup *), and bar-tau(sub w), and test time parameters such as bar-tau and particle time of flight t(sub f), are computed and compared with those evaluated by using Mirels' correlations. This article then discusses in detail the effects of flow nonuniformities on particle time-of-flight behind the normal shock and, consequently, on the interpretation of shock-tube data. This article concludes that for accurate interpretation of shock-tube data, a detailed analysis of flowfield parameters, using a computer code such as used in this study, must be performed.
Quinot, Catherine; Amsellem-Dubourget, Sylvie; Temam, Sofia; Sevin, Etienne; Barreto, Christine; Tackin, Arzu; Félicité, Jérémy; Lyon-Caen, Sarah; Siroux, Valérie; Girard, Raphaële; Descatha, Alexis; Le Moual, Nicole; Dumas, Orianne
2018-05-14
Healthcare workers are highly exposed to various types of disinfectants and cleaning products. Assessment of exposure to these products remains a challenge. We aimed to investigate the feasibility of a method, based on a smartphone application and bar codes, to improve occupational exposure assessment among hospital/cleaning workers in epidemiological studies. A database of disinfectants and cleaning products used in French hospitals, including their names, bar codes and composition, was developed using several sources: ProdHyBase (a database of disinfectants managed by hospital hygiene experts), and specific regulatory agencies and industrial websites. A smartphone application has been created to scan bar codes of products and fill a short questionnaire. The application was tested in a French hospital. The ease of use and the ability to record information through this new approach were estimated. The method was tested in a French hospital (7 units, 14 participants). Through the application, 126 records (one record referred to one product entered by one participant/unit) were registered, majority of which were liquids (55.5%) or sprays (23.8%); 20.6% were used to clean surfaces and 15.9% to clean toilets. Workers used mostly products with alcohol and quaternary ammonium compounds (>90% with weekly use), followed by hypochlorite bleach and hydrogen peroxide (28.6%). For most records, information was available on the name (93.7%) and bar code (77.0%). Information on product compounds was available for all products and recorded in the database. This innovative and easy-to-use method could help to improve the assessment of occupational exposure to disinfectants/cleaning products in epidemiological studies. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Uy, Raymonde Charles Y.; Kury, Fabricio P.; Fontelo, Paul A.
2015-01-01
The standard of safe medication practice requires strict observance of the five rights of medication administration: the right patient, drug, time, dose, and route. Despite adherence to these guidelines, medication errors remain a public health concern that has generated health policies and hospital processes that leverage automation and computerization to reduce these errors. Bar code, RFID, biometrics and pharmacy automation technologies have been demonstrated in literature to decrease the incidence of medication errors by minimizing human factors involved in the process. Despite evidence suggesting the effectivity of these technologies, adoption rates and trends vary across hospital systems. The objective of study is to examine the state and adoption trends of automatic identification and data capture (AIDC) methods and pharmacy automation technologies in U.S. hospitals. A retrospective descriptive analysis of survey data from the HIMSS Analytics® Database was done, demonstrating an optimistic growth in the adoption of these patient safety solutions. PMID:26958264
South wall, looking northwest, with scale bar U.S. Veterans ...
South wall, looking northwest, with scale bar - U.S. Veterans Hospital, Jefferson Barracks, Medical Officer in Charge Residence, VA Medical Center, Jefferson Barracks Division 1 Jefferson Barracks Drive, Saint Louis, Independent City, MO
Modular Track System For Positioning Mobile Robots
NASA Technical Reports Server (NTRS)
Miller, Jeff
1995-01-01
Conceptual system for positioning mobile robotic manipulators on large main structure includes modular tracks and ancillary structures assembled easily along with main structure. System, called "tracked robotic location system" (TROLS), originally intended for application to platforms in outer space, but TROLS concept might also prove useful on Earth; for example, to position robots in factories and warehouses. T-cross-section rail keeps mobile robot on track. Bar codes mark locations along track. Each robot equipped with bar-code-recognizing circuitry so it quickly finds way to assigned location.
Verification of Advective Bar Elements Implemented in the Aria Thermal Response Code.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mills, Brantley
2016-01-01
A verification effort was undertaken to evaluate the implementation of the new advective bar capability in the Aria thermal response code. Several approaches to the verification process were taken : a mesh refinement study to demonstrate solution convergence in the fluid and the solid, visually examining the mapping of the advective bar element nodes to the surrounding surfaces, and a comparison of solutions produced using the advective bars for simple geometries with solutions from commercial CFD software . The mesh refinement study has shown solution convergence for simple pipe flow in both temperature and velocity . Guidelines were provided tomore » achieve appropriate meshes between the advective bar elements and the surrounding volume. Simulations of pipe flow using advective bars elements in Aria have been compared to simulations using the commercial CFD software ANSYS Fluent (r) and provided comparable solutions in temperature and velocity supporting proper implementation of the new capability. Verification of Advective Bar Elements iv Acknowledgements A special thanks goes to Dean Dobranich for his guidance and expertise through all stages of this effort . His advice and feedback was instrumental to its completion. Thanks also goes to Sam Subia and Tolu Okusanya for helping to plan many of the verification activities performed in this document. Thank you to Sam, Justin Lamb and Victor Brunini for their assistance in resolving issues encountered with running the advective bar element model. Finally, thanks goes to Dean, Sam, and Adam Hetzler for reviewing the document and providing very valuable comments.« less
WRAP low level waste restricted waste management (LLW RWM) glovebox acceptance test report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leist, K.J.
1997-11-24
On April 22, 1997, the Low Level Waste Restricted Waste Management (LLW RWM) glovebox was tested using acceptance test procedure 13027A-87. Mr. Robert L. Warmenhoven served as test director, Mr. Kendrick Leist acted as test operator and test witness, and Michael Lane provided miscellaneous software support. The primary focus of the glovebox acceptance test was to examine glovebox control system interlocks, operator Interface Unit (OIU) menus, alarms, and messages. Basic drum port and lift table control sequences were demonstrated. OIU menus, messages, and alarm sequences were examined, with few exceptions noted. Barcode testing was bypassed, due to the lack ofmore » installed equipment as well as the switch from basic reliance on fixed bar code readers to the enhanced use of portable bar code readers. Bar code testing was completed during performance of the LLW RWM OTP. Mechanical and control deficiencies were documented as Test Exceptions during performance of this Acceptance Test. These items are attached as Appendix A to this report.« less
21 CFR 886.5800 - Ophthalmic bar reader.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar reader. 886.5800 Section 886.5800...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5800 Ophthalmic bar reader. (a) Identification. An ophthalmic bar reader is a device that consists of a magnifying lens intended for use by a...
The use of information technology to enhance patient safety and nursing efficiency.
Lee, Tso-Ying; Sun, Gi-Tseng; Kou, Li-Tseng; Yeh, Mei-Ling
2017-10-23
Issues in patient safety and nursing efficiency have long been of concern. Advancing the role of nursing informatics is seen as the best way to address this. The aim of this study was to determine if the use, outcomes and satisfaction with a nursing information system (NIS) improved patient safety and the quality of nursing care in a hospital in Taiwan. This study adopts a quasi-experimental design. Nurses and patients were surveyed by questionnaire and data retrieval before and after the implementation of NIS in terms of blood drawing, nursing process, drug administration, bar code scanning, shift handover, and information and communication integration. Physiologic values were easier to read and interpret; it took less time to complete electronic records (3.7 vs. 9.1 min); the number of errors in drug administration was reduced (0.08% vs. 0.39%); bar codes reduced the number of errors in blood drawing (0 vs. 10) and transportation of specimens (0 vs. 0.42%); satisfaction with electronic shift handover increased significantly; there was a reduction in nursing turnover (14.9% vs. 16%); patient satisfaction increased significantly (3.46 vs. 3.34). Introduction of NIS improved patient safety and nursing efficiency and increased nurse and patient satisfaction. Medical organizations must continually improve the nursing information system if they are to provide patients with high quality service in a competitive environment.
Deciphering the BAR code of membrane modulators.
Salzer, Ulrich; Kostan, Julius; Djinović-Carugo, Kristina
2017-07-01
The BAR domain is the eponymous domain of the "BAR-domain protein superfamily", a large and diverse set of mostly multi-domain proteins that play eminent roles at the membrane cytoskeleton interface. BAR domain homodimers are the functional units that peripherally associate with lipid membranes and are involved in membrane sculpting activities. Differences in their intrinsic curvatures and lipid-binding properties account for a large variety in membrane modulating properties. Membrane activities of BAR domains are further modified and regulated by intramolecular or inter-subunit domains, by intermolecular protein interactions, and by posttranslational modifications. Rather than providing detailed cell biological information on single members of this superfamily, this review focuses on biochemical, biophysical, and structural aspects and on recent findings that paradigmatically promote our understanding of processes driven and modulated by BAR domains.
ASHP national survey of pharmacy practice in hospital settings: dispensing and administration--2011.
Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J
2012-05-01
Results of the 2011 ASHP national survey of pharmacy practice in hospital settings that pertain to dispensing and administration are presented. A stratified random sample of pharmacy directors at 1401 general and children's medical-surgical hospitals in the United States were surveyed by mail. In this national probability sample survey, the response rate was 40.1%. Decentralization of the medication-use system continues, with 40% of hospitals using a decentralized system and 58% of hospitals planning to use a decentralized model in the future. Automated dispensing cabinets were used by 89% of hospitals, robots were used by 11%, carousels were used in 18%, and machine-readable coding was used in 34% of hospitals to verify doses before dispensing. Overall, 65% of hospitals had a United States Pharmacopeia chapter 797 compliant cleanroom for compounding sterile preparations. Medication administration records (MARs) have become increasingly computerized, with 67% of hospitals using electronic MARs. Bar-code-assisted medication administration was used in 50% of hospitals, and 68% of hospitals had smart infusion pumps. Health information is becoming more electronic, with 67% of hospitals having partially or completely implemented an electronic health record and 34% of hospitals having computerized prescriber order entry. The use of these technologies has substantially increased over the past year. The average number of full-time equivalent staff per 100 occupied beds averaged 17.5 for pharmacists and 15.0 for technicians. Directors of pharmacy reported declining vacancy rates for pharmacists. Pharmacists continue to improve medication use at the dispensing and administration steps of the medication-use system. The adoption of new technology is changing the philosophy of medication distribution, and health information is rapidly becoming electronic.
Quality and efficiency successes leveraging IT and new processes.
Chaiken, Barry P; Christian, Charles E; Johnson, Liz
2007-01-01
Today, healthcare annually invests billions of dollars in information technology, including clinical systems, electronic medical records and interoperability platforms. While continued investment and parallel development of standards are critical to secure exponential benefits from clinical information technology, intelligent and creative redesign of processes through path innovation is necessary to deliver meaningful value. Reports from two organizations included in this report review the steps taken to reinvent clinical processes that best leverage information technology to deliver safer and more efficient care. Good Samaritan Hospital, Vincennes, Indiana, implemented electronic charting, point-of-care bar coding of medications prior to administration, and integrated clinical documentation for nursing, laboratory, radiology and pharmacy. Tenet Healthcare, during its implementation and deployment of multiple clinical systems across several hospitals, focused on planning that included team-based process redesign. In addition, Tenet constructed valuable and measurable metrics that link outcomes with its strategic goals.
van der Veen, Willem; van den Bemt, Patricia M L A; Wouters, Hans; Bates, David W; Twisk, Jos W R; de Gier, Johan J; Taxis, Katja; Duyvendak, Michiel; Luttikhuis, Karen Oude; Ros, Johannes J W; Vasbinder, Erwin C; Atrafi, Maryam; Brasse, Bjorn; Mangelaars, Iris
2018-04-01
To study the association of workarounds with medication administration errors using barcode-assisted medication administration (BCMA), and to determine the frequency and types of workarounds and medication administration errors. A prospective observational study in Dutch hospitals using BCMA to administer medication. Direct observation was used to collect data. Primary outcome measure was the proportion of medication administrations with one or more medication administration errors. Secondary outcome was the frequency and types of workarounds and medication administration errors. Univariate and multivariate multilevel logistic regression analysis were used to assess the association between workarounds and medication administration errors. Descriptive statistics were used for the secondary outcomes. We included 5793 medication administrations for 1230 inpatients. Workarounds were associated with medication administration errors (adjusted odds ratio 3.06 [95% CI: 2.49-3.78]). Most commonly, procedural workarounds were observed, such as not scanning at all (36%), not scanning patients because they did not wear a wristband (28%), incorrect medication scanning, multiple medication scanning, and ignoring alert signals (11%). Common types of medication administration errors were omissions (78%), administration of non-ordered drugs (8.0%), and wrong doses given (6.0%). Workarounds are associated with medication administration errors in hospitals using BCMA. These data suggest that BCMA needs more post-implementation evaluation if it is to achieve the intended benefits for medication safety. In hospitals using barcode-assisted medication administration, workarounds occurred in 66% of medication administrations and were associated with large numbers of medication administration errors.
Changes in smoking-related norms in bars resulting from California's Smoke-Free Workplace Act.
Satterlund, Travis D; Lee, Juliet P; Moore, Roland S
2012-01-01
California's Smoke-Free Workplace Act--CA Labor Code Sec. 6404.5(a)--was extended to bars in 1998. This article analyzes changes in normative beliefs and behaviors related to bar smoking in the decade following the adoption of the Act. In a series of studies evaluating the smoke-free workplace law in bars, researchers conducted extensive observations and interviews with bar staff and patrons, health officials, and law enforcement personnel in three California counties. Smoking outside became a normal pause in the social environment and created a new type of bar socializing for outside smokers. Although some bar owners and staff reported initially resenting the responsibility to uphold the law, once norms regarding cigarettes and smoking began changing, bar workers experienced less conflict in upholding the law. Non-smoking behavior within bars also became the normative behavior for bar patrons. California's Smoke-Free Workplace Act has both reflected and encouraged normative beliefs and behaviors related to smoking in bars. The findings indicate that such shifts are possible even in contexts where smoking behaviors and attitudes supporting smoking were deeply entrenched. Recommendations include attending to the synergistic effect of education and policy in effective tobacco control programs.
Parallel coding of conjunctions in visual search.
Found, A
1998-10-01
Two experiments investigated whether the conjunctive nature of nontarget items influenced search for a conjunction target. Each experiment consisted of two conditions. In both conditions, the target item was a red bar tilted to the right, among white tilted bars and vertical red bars. As well as color and orientation, display items also differed in terms of size. Size was irrelevant to search in that the size of the target varied randomly from trial to trial. In one condition, the size of items correlated with the other attributes of display items (e.g., all red items were big and all white items were small). In the other condition, the size of items varied randomly (i.e., some red items were small and some were big, and some white items were big and some were small). Search was more efficient in the size-correlated condition, consistent with the parallel coding of conjunctions in visual search.
LBE water interaction in sub-critical reactors: First experimental and modelling results
NASA Astrophysics Data System (ADS)
Ciampichetti, A.; Agostini, P.; Benamati, G.; Bandini, G.; Pellini, D.; Forgione, N.; Oriolo, F.; Ambrosini, W.
2008-06-01
This paper concerns the study of the phenomena involved in the interaction between LBE and pressurised water which could occur in some hypothetical accidents in accelerator driven system type reactors. The LIFUS 5 facility was designed and built at ENEA-Brasimone to reproduce this kind of interaction in a wide range of conditions. The first test of the experimental program was carried out injecting water at 70 bar and 235 °C in a reaction vessel containing LBE at 1 bar and 350 °C. A pressurisation up to 80 bar was observed in the test section during the considered transient. The SIMMER III code was used to simulate the performed test. The calculated data agree in a satisfactory way with the experimental results giving confidence in the possibility to use this code for safety analyses of heavy liquid metal cooled reactors.
NASA Astrophysics Data System (ADS)
Ludwig, J.; Lindhorst, S.; Betzler, C.; Bierstedt, S. E.; Borówka, R. K.
2017-08-01
It is shown that coastal dunes bear a so far unread archive of annual wind intensity. Active dunes at the Polish coast near Łeba consist of two genetic units: primary dunes with up to 18 m high eastward-dipping foresets, temporarily superimposed by smaller secondary dunes. Ground-penetrating radar (GPR) data reveal that the foresets of the primary dunes are bundled into alternating packages imaged as either low- or high-amplitude reflections. High-amplitude packages are composed of quartz sand with intercalated heavy-minerals layers. Low-amplitude packages lack these heavy-mineral concentrations. Dune net-progradation is towards the east, reflecting the prevalence of westerly winds. Winds blowing parallel to the dune crest winnow the lee slope, leaving layers enriched in heavy minerals. Sediment transport to the slip face of the dunes is enhanced during the winter months, whereas winnowing predominantly takes place during the spring to autumn months, when the wind field is bi-directional. As a consequence of this seasonal shift, the sedimentary record of one year comprises one low- and one high-amplitude GPR reflection interval. This sedimentary pattern is a persistent feature of the Łeba dunes and recognized to resemble a sedimentary "bar code". To overcome hiatuses in the bar code of individual dunes and dune-to-dune variations in bar-code quality, dendrochronological methods were adopted to compile a composite bar code from several dunes. The resulting data series shows annual variations in west-wind intensity at the southern Baltic coast for the time period 1987 to 2012. Proxy-based wind data are validated against instrumental based weather observations.
Structural Behavior of Concrete Beams Reinforced with Basalt Fiber Reinforced Polymer (BFRP) Bars
NASA Astrophysics Data System (ADS)
Ovitigala, Thilan
The main challenge for civil engineers is to provide sustainable, environmentally friendly and financially feasible structures to the society. Finding new materials such as fiber reinforced polymer (FRP) material that can fulfill the above requirements is a must. FRP material was expensive and it was limited to niche markets such as space shuttles and air industry in the 1960s. Over the time, it became cheaper and spread to other industries such as sporting goods in the 1980-1990, and then towards the infrastructure industry. Design and construction guidelines are available for carbon fiber reinforced polymer (CFRP), aramid fiber reinforced polymer (AFRP) and glass fiber reinforced polymer (GFRP) and they are currently used in structural applications. Since FRP is linear elastic brittle material, design guidelines for the steel reinforcement are not valid for FRP materials. Corrosion of steel reinforcement affects the durability of the concrete structures. FRP reinforcement is identified as an alternative to steel reinforcement in corrosive environments. Although basalt fiber reinforced polymer (BFRP) has many advantages over other FRP materials, but limited studies have been done. These studies didn't include larger BFRP bar diameters that are mostly used in practice. Therefore, larger beam sizes with larger BFRP reinforcement bar diameters are needed to investigate the flexural and shear behavior of BFRP reinforced concrete beams. Also, shear behavior of BFRP reinforced concrete beams was not yet studied. Experimental testing of mechanical properties and bond strength of BFRP bars and flexural and shear behavior of BFRP reinforced concrete beams are needed to include BFRP reinforcement bars in the design codes. This study mainly focuses on the use of BFRP bars as internal reinforcement. The test results of the mechanical properties of BFRP reinforcement bars, the bond strength of BFRP reinforcement bars, and the flexural and shear behavior of concrete beams reinforced with BFRP reinforcement bars are presented and verified with other research studies, existing design codes and guidelines provided for other FRP bars. Based on the experimental testing results, analytical equations were developed and existing equations were modified to predict the actual structural behavior of FRP bar reinforced concrete beams with reasonable accuracy.
21 CFR 886.5800 - Ophthalmic bar reader.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ophthalmic bar reader. 886.5800 Section 886.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5800 Ophthalmic bar reader. (a...
The dynamics of stellar discs in live dark-matter haloes
NASA Astrophysics Data System (ADS)
Fujii, M. S.; Bédorf, J.; Baba, J.; Portegies Zwart, S.
2018-06-01
Recent developments in computer hardware and software enable researchers to simulate the self-gravitating evolution of galaxies at a resolution comparable to the actual number of stars. Here we present the results of a series of such simulations. We performed N-body simulations of disc galaxies with between 100 and 500 million particles over a wide range of initial conditions. Our calculations include a live bulge, disc, and dark-matter halo, each of which is represented by self-gravitating particles in the N-body code. The simulations are performed using the gravitational N-body tree-code BONSAI running on the Piz Daint supercomputer. We find that the time-scale over which the bar forms increases exponentially with decreasing disc-mass fraction and that the bar formation epoch exceeds a Hubble time when the disc-mass fraction is ˜0.35. These results can be explained with the swing-amplification theory. The condition for the formation of m = 2 spirals is consistent with that for the formation of the bar, which is also an m = 2 phenomenon. We further argue that the non-barred grand-design spiral galaxies are transitional, and that they evolve to barred galaxies on a dynamical time-scale. We also confirm that the disc-mass fraction and shear rate are important parameters for the morphology of disc galaxies. The former affects the number of spiral arms and the bar formation epoch, and the latter determines the pitch angle of the spiral arms.
Development of highly efficient laser bars emitting at around 1060 nm for medical applications
NASA Astrophysics Data System (ADS)
Pietrzak, Agnieszka; Zorn, Martin; Meusel, Jens; Huelsewede, Ralf; Sebastian, Juergen
2018-02-01
An overview is presented on the recent progress in the development of high power laser bars at wavelengths around 1060nm. The development is focused on highly efficient and reliable laser performance under pulsed operation for medical applications. The epitaxial structure and lateral layout of the laser bars were tailored to meet the application requirements. Reliable operation peak powers of 350W and 500W are demonstrated from laser bars with fill-factor FF=75% and resonator lengths 1.5mm and 2.0mm, respectively. Moreover, 60W at current 65A with lifetime <10.000h are presented. The power scaling with fill-factor enables a cost reduction ($/W) up to 35%.
Technology utilization to prevent medication errors.
Forni, Allison; Chu, Hanh T; Fanikos, John
2010-01-01
Medication errors have been increasingly recognized as a major cause of iatrogenic illness and system-wide improvements have been the focus of prevention efforts. Critically ill patients are particularly vulnerable to injury resulting from medication errors because of the severity of illness, need for high risk medications with a narrow therapeutic index and frequent use of intravenous infusions. Health information technology has been identified as method to reduce medication errors as well as improve the efficiency and quality of care; however, few studies regarding the impact of health information technology have focused on patients in the intensive care unit. Computerized physician order entry and clinical decision support systems can play a crucial role in decreasing errors in the ordering stage of the medication use process through improving the completeness and legibility of orders, alerting physicians to medication allergies and drug interactions and providing a means for standardization of practice. Electronic surveillance, reminders and alerts identify patients susceptible to an adverse event, communicate critical changes in a patient's condition, and facilitate timely and appropriate treatment. Bar code technology, intravenous infusion safety systems, and electronic medication administration records can target prevention of errors in medication dispensing and administration where other technologies would not be able to intercept a preventable adverse event. Systems integration and compliance are vital components in the implementation of health information technology and achievement of a safe medication use process.
Samaranayake, N R; Cheung, S T D; Cheng, K; Lai, K; Chui, W C M; Cheung, B M Y
2014-06-01
We assessed the effects of a bar-code assisted medication administration system used without the support of computerised prescribing (stand-alone BCMA), on the dispensing process and its users. The stand-alone BCMA system was implemented in one ward of a teaching hospital. The number of dispensing steps, dispensing time and potential dispensing errors (PDEs) were directly observed one month before and eight months after the intervention. Attitudes of pharmacy and nursing staff were assessed using a questionnaire (Likert scale) and interviews. Among 1291 and 471 drug items observed before and after the introduction of the technology respectively, the number of dispensing steps increased from five to eight and time (standard deviation) to dispense one drug item by one staff personnel increased from 0.8 (0.09) to 1.5 (0.12) min. Among 2828 and 471 drug items observed before and after the intervention respectively, the number of PDEs increased significantly (P<0.001). 'Procedural errors' and 'missing drug items' were the frequently observed PDEs in the after study. 'Perceived usefulness' and 'job relevance' of the technology decreased significantly (P=0.003 and P=0.004 respectively) among users who participated in the before (N=16) and after (N=16) questionnaires surveys. Among the interviewees, pharmacy staff felt that the system offered less benefit to the dispensing process (9/16). Nursing staff perceived the system as useful in improving the accuracy of drug administration (7/10). Implementing a stand-alone BCMA system may slow down and complicate the dispensing process. Nursing staff believe the stand-alone BCMA system could improve the drug administration process but pharmacy staff believes the technology would be more helpful if supported by computerised prescribing. However, periodical assessments are needed to identify weaknesses in the process after implementation, and all users should be educated on the benefits of using this technology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Squeezed Back-to-Back Correlation of {D}^{0}{\\bar{D}}^{0} in Relativistic Heavy-Ion Collisions
NASA Astrophysics Data System (ADS)
Yang, Ai-Geng; Zhang, Yong; Cheng, Luan; Sun, Hao; Zhang, Wei-Ning
2018-05-01
We investigate the squeezed back-to-back correlation (BBC) of $D^0\\!{\\bar D}^0$ in relativistic heavy-ion collisions, using the in-medium mass modification calculated with a self-energy in hot pion gas and the source space-time distributions provided by the viscous hydrodynamic code VISH2+1. It is found that the BBC of $D^0\\!{\\bar D}^0$ is significant in peripheral Au+Au collisions at the RHIC energy. A possible way to detect the BBC in experiment is presented.
Changes in Smoking-Related Norms in Bars Resulting from California’s Smoke-Free Workplace Act*
Satterlund, Travis D.; Lee, Juliet P.; Moore, Roland S.
2013-01-01
California’s Smoke-Free Workplace Act— CA Labor Code Sec. 6404.5(a)—was extended to bars in 1998. This paper analyzes changes in normative beliefs and behaviors related to bar smoking in the decade following the adoption of the Act. In a series of studies evaluating the smoke-free workplace law in bars, researchers conducted extensive observations and interviews with bar staff and patrons, health officials, and law enforcement personnel in three California counties. Smoking outside became a normal pause in the social environment and created a new type of bar socializing for outside smokers. Although some bar owners and staff reported initially resenting the responsibility to uphold the law, once norms regarding cigarettes and smoking began changing, bar workers experienced less conflict in upholding the law. Non-smoking behavior within bars also became the normative behavior for bar patrons. California’s Smoke-Free Workplace Act has both reflected and encouraged normative beliefs and behaviors related to smoking in bars. The findings indicate that such shifts are possible even in contexts where smoking behaviors and attitudes supporting smoking were deeply entrenched. Recommendations include attending to the synergistic effect of education and policy in effective tobacco control programs. PMID:23705511
The intrinsic three-dimensional shape of galactic bars
NASA Astrophysics Data System (ADS)
Méndez-Abreu, J.; Costantin, L.; Aguerri, J. A. L.; de Lorenzo-Cáceres, A.; Corsini, E. M.
2018-06-01
We present the first statistical study on the intrinsic three-dimensional (3D) shape of a sample of 83 galactic bars extracted from the CALIFA survey. We use the galaXYZ code to derive the bar intrinsic shape with a statistical approach. The method uses only the geometric information (ellipticities and position angles) of bars and discs obtained from a multi-component photometric decomposition of the galaxy surface-brightness distributions. We find that bars are predominantly prolate-triaxial ellipsoids (68%), with a small fraction of oblate-triaxial ellipsoids (32%). The typical flattening (intrinsic C/A semiaxis ratio) of the bars in our sample is 0.34, which matches well the typical intrinsic flattening of stellar discs at these galaxy masses. We demonstrate that, for prolate-triaxial bars, the intrinsic shape of bars depends on the galaxy Hubble type and stellar mass (bars in massive S0 galaxies are thicker and more circular than those in less massive spirals). The bar intrinsic shape correlates with bulge, disc, and bar parameters. In particular with the bulge-to-total (B/T) luminosity ratio, disc g - r color, and central surface brightness of the bar, confirming the tight link between bars and their host galaxies. Combining the probability distributions of the intrinsic shape of bulges and bars in our sample we show that 52% (16%) of bulges are thicker (flatter) than the surrounding bar at 1σ level. We suggest that these percentages might be representative of the fraction of classical and disc-like bulges in our sample, respectively.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Navigation Area (RNA) includes all navigable waters of the Humboldt Bay Bar Channel and the Humboldt Bay Entrance Channel, Humboldt Bay, California. (b) Definitions. As used in this section— COTP means the Captain of the Port as defined in Title 33, Code of Federal Regulations, Section 1.01-30 and 3.55-20...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Navigation Area (RNA) includes all navigable waters of the Humboldt Bay Bar Channel and the Humboldt Bay Entrance Channel, Humboldt Bay, California. (b) Definitions. As used in this section— COTP means the Captain of the Port as defined in Title 33, Code of Federal Regulations, Section 1.01-30 and 3.55-20...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Navigation Area (RNA) includes all navigable waters of the Humboldt Bay Bar Channel and the Humboldt Bay Entrance Channel, Humboldt Bay, California. (b) Definitions. As used in this section— COTP means the Captain of the Port as defined in Title 33, Code of Federal Regulations, Section 1.01-30 and 3.55-20...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Navigation Area (RNA) includes all navigable waters of the Humboldt Bay Bar Channel and the Humboldt Bay Entrance Channel, Humboldt Bay, California. (b) Definitions. As used in this section— COTP means the Captain of the Port as defined in Title 33, Code of Federal Regulations, Section 1.01-30 and 3.55-20...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Navigation Area (RNA) includes all navigable waters of the Humboldt Bay Bar Channel and the Humboldt Bay Entrance Channel, Humboldt Bay, California. (b) Definitions. As used in this section— COTP means the Captain of the Port as defined in Title 33, Code of Federal Regulations, Section 1.01-30 and 3.55-20...
El Camino Hospital: using health information technology to promote patient safety.
Bukunt, Susan; Hunter, Christine; Perkins, Sharon; Russell, Diana; Domanico, Lee
2005-10-01
El Camino Hospital is a leader in the use of health information technology to promote patient safety, including bar coding, computerized order entry, electronic medical records, and wireless communications. Each year, El Camino Hospital's board of directors sets performance expectations for the chief executive officer, which are tied to achievement of local, regional, and national safety and quality standards, including the six Institute of Medicine quality dimensions. He then determines a set of explicit quality goals and measurable actions, which serve as guidelines for the overall hospital. The goals and progress reports are widely shared with employees, medical staff, patients and families, and the public. For safety, for example, the medication error reduction team tracks and reviews medication error rates. The hospital has virtually eliminated transcription errors through its 100% use of computerized physician order entry. Clinical pathways and standard order sets have reduced practice variation, providing a safer environment. Many projects focused on timeliness, such as emergency department wait time, lab turnaround time, and pneumonia time to initial antibiotic. Results have been mixed, with projects most successful when a link was established with patient outcomes, such as in reducing time to percutaneous transluminal coronary angioplasty for patients with acute myocardial infarction.
Digitized forensics: retaining a link between physical and digital crime scene traces using QR-codes
NASA Astrophysics Data System (ADS)
Hildebrandt, Mario; Kiltz, Stefan; Dittmann, Jana
2013-03-01
The digitization of physical traces from crime scenes in forensic investigations in effect creates a digital chain-of-custody and entrains the challenge of creating a link between the two or more representations of the same trace. In order to be forensically sound, especially the two security aspects of integrity and authenticity need to be maintained at all times. Especially the adherence to the authenticity using technical means proves to be a challenge at the boundary between the physical object and its digital representations. In this article we propose a new method of linking physical objects with its digital counterparts using two-dimensional bar codes and additional meta-data accompanying the acquired data for integration in the conventional documentation of collection of items of evidence (bagging and tagging process). Using the exemplary chosen QR-code as particular implementation of a bar code and a model of the forensic process, we also supply a means to integrate our suggested approach into forensically sound proceedings as described by Holder et al.1 We use the example of the digital dactyloscopy as a forensic discipline, where currently progress is being made by digitizing some of the processing steps. We show an exemplary demonstrator of the suggested approach using a smartphone as a mobile device for the verification of the physical trace to extend the chain-of-custody from the physical to the digital domain. Our evaluation of the demonstrator is performed towards the readability and the verification of its contents. We can read the bar code despite its limited size of 42 x 42 mm and rather large amount of embedded data using various devices. Furthermore, the QR-code's error correction features help to recover contents of damaged codes. Subsequently, our appended digital signature allows for detecting malicious manipulations of the embedded data.
Laser Scanner For Automatic Storage
NASA Astrophysics Data System (ADS)
Carvalho, Fernando D.; Correia, Bento A.; Rebordao, Jose M.; Rodrigues, F. Carvalho
1989-01-01
The automated magazines are beeing used at industry more and more. One of the problems related with the automation of a Store House is the identification of the products envolved. Already used for stock management, the Bar Codes allows an easy way to identify one product. Applied to automated magazines, the bar codes allows a great variety of items in a small code. In order to be used by the national producers of automated magazines, a devoted laser scanner has been develloped. The Prototype uses an He-Ne laser whose beam scans a field angle of 75 degrees at 16 Hz. The scene reflectivity is transduced by a photodiode into an electrical signal, which is then binarized. This digital signal is the input of the decodifying program. The machine is able to see barcodes and to decode the information. A parallel interface allows the comunication with the central unit, which is responsible for the management of automated magazine.
The Top 100. The Fastest Growing Careers for the 21st Century. Revised Edition.
ERIC Educational Resources Information Center
1998
This publication presents 100 careers the U.S. Department of Labor and other sources project as the fastest growing through the year 2006. A shaded bar on the bottom of the title page of each article contains a listing of codes for three commonly used government classification systems. Shaded bars at the bottom of other pages provide quick facts.…
Population responses in V1 encode different figures by response amplitude.
Gilad, Ariel; Slovin, Hamutal
2015-04-22
The visual system simultaneously segregates between several objects presented in a visual scene. The neural code for encoding different objects or figures is not well understood. To study this question, we trained two monkeys to discriminate whether two elongated bars are either separate, thus generating two different figures, or connected, thus generating a single figure. Using voltage-sensitive dyes, we imaged at high spatial and temporal resolution V1 population responses evoked by the two bars, while keeping their local attributes similar among the two conditions. In the separate condition, unlike the connected condition, the population response to one bar is enhanced, whereas the response to the other is simultaneously suppressed. The response to the background remained unchanged between the two conditions. This divergent pattern developed ∼200 ms poststimulus onset and could discriminate well between the separate and connected single trials. The stimulus separation saliency and behavioral report were highly correlated with the differential response to the bars. In addition, the proximity and/or the specific location of the connectors seemed to have only a weak effect on this late activity pattern, further supporting the involvement of top-down influences. Additional neural codes were less informative about the separate and connected conditions, with much less consistency and discriminability compared with a response amplitude code. We suggest that V1 is involved in the encoding of each figure by different neuronal response amplitude, which can mediate their segregation and perception. Copyright © 2015 the authors 0270-6474/15/356335-15$15.00/0.
Wei, Jiao; Cheng, Fu; Qun, Qu; Nurbek; Xu, Shi-Dong; Sun, Li-Feng; Han, Xin-Kui; Muhan; Han, Ling-Ling; Irixiati; Jie, Peng; Zhang, Ke-Jiu; Islayin; Chai, Jun-jie
2005-12-01
To assess the epidemiological efficacy of type SRP III slow-released praziquantel-medicated bars for dogs in the prevention and control of cystic echinococcosis in man and livestock, praziquantel-medicated bars were implanted subcutaneously in over 90% of dogs in villages in north Xinjiang, China, where cystic echinococcosis is highly endemic. After implantation, infection rate of Echinococcus granulosus in dogs, specific antibodies in children and prevalence of echinococcosis in one-year-old lambs were observed for 3 years. Coproantigen of E. granulosus was positive in 41.2% of the dogs at the start of experiment. In the second and third year after medicated-bar implantation, coproantigen was undetectable in any dogs examined, while 3.0% of dogs were positive at the end of the fourth year. The antibody positive rate in 7-year-old pupils, that was 41.2% before the experiment, declined gradually and it was 5.4% in the fourth year, while children in the non-intervention control area showed 30.6% seropositivity. The prevalence of hydatid disease in children aged 7-16 years also declined significantly. The prevalence of hydatidosis in lambs one year of age was 44.8% in the first year, dropping to 10.7% in the fourth year, while in the non-intervention control area the level of infection was 46.4%. These results demonstrated not only that the slow released praziquantel-medicated bars efficiently blocked reinfection in dogs at least for 2 years, but also the measure was effective in preventing transmission of cystic echinococcosis to both man and livestock.
NASA Astrophysics Data System (ADS)
Busquet, Michel; Klapisch, Marcel; Bar-Shalom, Avi; Oreg, Josse
2010-11-01
The main contribution to spectral properties of astrophysics mixtures come often from Iron. On the other hand, in the so-called domain of ``Laboratory Astrophysics,'' where astrophysics phenomena are scaled down to the laboratory, Xenon (and Argon) are commonly used gases. At so called ``warm'' temperatures (T=5-50eV), L-shell Iron and M-shell Xenon present a very large number of spectral lines, originating from billions of levels. More often than not, Local Thermodynamical Equilibrium is assumed, leading to noticeable simplification of the computation. Nevertheless, complex and powerful atomic structure codes are required. We take benefit of powerful statistics and numerics, included in our atomic structure codes, STA[1] and HULLAC[2], to generate the required spectra. Recent improvements in both fields (statistics, numerics and convergence control) allow obtaining large databases (ro x T grid of > 200x200 points, and > 10000 frequencies) for temperature down to a few eV. We plan to port these improvements in the NLTE code SCROLL[3]. [1] A.Bar-Shalom, et al, Phys. Rev. A 40, 3183 (1989) [2] M.Busquet,et al, J.Phys. IV France 133, 973-975 (2006); A.Bar-Shalom, M.Klapisch, J.Oreg, J.Oreg, JQSRT 71, 169, (2001) [3] A.Bar-Shalom, et al, Phys. Rev. E 56, R70 (1997)
1997-09-01
Medical Center. Ft. Lewis, WA. 3. Auditorium, Senior NCO Academy. Gunter AFB, AL. 4. Snack Bar, Senior NCO Academy. Gunter AFB, AL. 5. Atrium, Marshall...and enable people to perform to their maximum potential. ivGuide to Excellent Interiors Clinic Waiting, Minot AFB Auditorium, Gunter AFB Snack Shop...Medical Center. Ft. Lewis, WA. 3. Auditorium, Senior NCO Academy. Gunter AFB, AL. 4. Snack Bar, Senior NCO Academy. Gunter AFB, AL. 5. Atrium, Marshall Hall
Predictive Coding: A Possible Explanation of Filling-In at the Blind Spot
Raman, Rajani; Sarkar, Sandip
2016-01-01
Filling-in at the blind spot is a perceptual phenomenon in which the visual system fills the informational void, which arises due to the absence of retinal input corresponding to the optic disc, with surrounding visual attributes. It is known that during filling-in, nonlinear neural responses are observed in the early visual area that correlates with the perception, but the knowledge of underlying neural mechanism for filling-in at the blind spot is far from complete. In this work, we attempted to present a fresh perspective on the computational mechanism of filling-in process in the framework of hierarchical predictive coding, which provides a functional explanation for a range of neural responses in the cortex. We simulated a three-level hierarchical network and observe its response while stimulating the network with different bar stimulus across the blind spot. We find that the predictive-estimator neurons that represent blind spot in primary visual cortex exhibit elevated non-linear response when the bar stimulated both sides of the blind spot. Using generative model, we also show that these responses represent the filling-in completion. All these results are consistent with the finding of psychophysical and physiological studies. In this study, we also demonstrate that the tolerance in filling-in qualitatively matches with the experimental findings related to non-aligned bars. We discuss this phenomenon in the predictive coding paradigm and show that all our results could be explained by taking into account the efficient coding of natural images along with feedback and feed-forward connections that allow priors and predictions to co-evolve to arrive at the best prediction. These results suggest that the filling-in process could be a manifestation of the general computational principle of hierarchical predictive coding of natural images. PMID:26959812
Automated collection and processing of environmental samples
Troyer, Gary L.; McNeece, Susan G.; Brayton, Darryl D.; Panesar, Amardip K.
1997-01-01
For monitoring an environmental parameter such as the level of nuclear radiation, at distributed sites, bar coded sample collectors are deployed and their codes are read using a portable data entry unit that also records the time of deployment. The time and collector identity are cross referenced in memory in the portable unit. Similarly, when later recovering the collector for testing, the code is again read and the time of collection is stored as indexed to the sample collector, or to a further bar code, for example as provided on a container for the sample. The identity of the operator can also be encoded and stored. After deploying and/or recovering the sample collectors, the data is transmitted to a base processor. The samples are tested, preferably using a test unit coupled to the base processor, and again the time is recorded. The base processor computes the level of radiation at the site during exposure of the sample collector, using the detected radiation level of the sample, the delay between recovery and testing, the duration of exposure and the half life of the isotopes collected. In one embodiment, an identity code and a site code are optically read by an image grabber coupled to the portable data entry unit.
Parametric Study of Shear Strength of Concrete Beams Reinforced with FRP Bars
NASA Astrophysics Data System (ADS)
Thomas, Job; Ramadass, S.
2016-09-01
Fibre Reinforced Polymer (FRP) bars are being widely used as internal reinforcement in structural elements in the last decade. The corrosion resistance of FRP bars qualifies its use in severe and marine exposure conditions in structures. A total of eight concrete beams longitudinally reinforced with FRP bars were cast and tested over shear span to depth ratio of 0.5 and 1.75. The shear strength test data of 188 beams published in various literatures were also used. The model originally proposed by Indian Standard Code of practice for the prediction of shear strength of concrete beams reinforced with steel bars IS:456 (Plain and reinforced concrete, code of practice, fourth revision. Bureau of Indian Standards, New Delhi, 2000) is considered and a modification to account for the influence of the FRP bars is proposed based on regression analysis. Out of the 196 test data, 110 test data is used for the regression analysis and 86 test data is used for the validation of the model. In addition, the shear strength of 86 test data accounted for the validation is assessed using eleven models proposed by various researchers. The proposed model accounts for compressive strength of concrete ( f ck ), modulus of elasticity of FRP rebar ( E f ), longitudinal reinforcement ratio ( ρ f ), shear span to depth ratio ( a/ d) and size effect of beams. The predicted shear strength of beams using the proposed model and 11 models proposed by other researchers is compared with the corresponding experimental results. The mean of predicted shear strength to the experimental shear strength for the 86 beams accounted for the validation of the proposed model is found to be 0.93. The result of the statistical analysis indicates that the prediction based on the proposed model corroborates with the corresponding experimental data.
76 FR 49772 - Guidance for Industry: Bar Code Label Requirements-Questions and Answers; Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-11
... other FDA initiatives, such as efforts to further enhance the security of the drug supply chain through... response concerns the ability of vaccine manufacturers to use alternative coding technologies to the linear... Management (HFA-305), Food and Drug Administration, 5630 Fishers Lane, rm. 1061, Rockville, MD 20852. FOR...
The method for maintaining and recording electronic Chain-of-Custody (CoC) Records for CTEPP samples is summarized in this SOP. The CoC Records that will be logged electronically include the creation of a sample's identification code, bar code labels, and hard-copy CoC document...
Caruccio, Nicholas
2011-01-01
DNA library preparation is a common entry point and bottleneck for next-generation sequencing. Current methods generally consist of distinct steps that often involve significant sample loss and hands-on time: DNA fragmentation, end-polishing, and adaptor-ligation. In vitro transposition with Nextera™ Transposomes simultaneously fragments and covalently tags the target DNA, thereby combining these three distinct steps into a single reaction. Platform-specific sequencing adaptors can be added, and the sample can be enriched and bar-coded using limited-cycle PCR to prepare di-tagged DNA fragment libraries. Nextera technology offers a streamlined, efficient, and high-throughput method for generating bar-coded libraries compatible with multiple next-generation sequencing platforms.
Implementation of the Regulatory Authority Information System in Egypt
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carson, S.D.; Schetnan, R.; Hasan, A.
2006-07-01
As part of the implementation of a bar-code-based system to track radioactive sealed sources (RSS) in Egypt, the Regulatory Authority Information System Personal Digital Assistant (RAIS PDA) Application was developed to extend the functionality of the International Atomic Energy Agency's (IAEA's) RAIS database by allowing users to download RSS data from the database to a portable PDA equipped with a bar-code scanner. [1, 4] The system allows users in the field to verify radioactive sealed source data, gather radioactive sealed source audit information, and upload that data to the RAIS database. This paper describes the development of the RAIS PDAmore » Application, its features, and how it will be implemented in Egypt. (authors)« less
Impact of Frequent Interruption on Nurses' Patient-Controlled Analgesia Programming Performance.
Campoe, Kristi R; Giuliano, Karen K
2017-12-01
The purpose was to add to the body of knowledge regarding the impact of interruption on acute care nurses' cognitive workload, total task completion times, nurse frustration, and medication administration error while programming a patient-controlled analgesia (PCA) pump. Data support that the severity of medication administration error increases with the number of interruptions, which is especially critical during the administration of high-risk medications. Bar code technology, interruption-free zones, and medication safety vests have been shown to decrease administration-related errors. However, there are few published data regarding the impact of number of interruptions on nurses' clinical performance during PCA programming. Nine acute care nurses completed three PCA pump programming tasks in a simulation laboratory. Programming tasks were completed under three conditions where the number of interruptions varied between two, four, and six. Outcome measures included cognitive workload (six NASA Task Load Index [NASA-TLX] subscales), total task completion time (seconds), nurse frustration (NASA-TLX Subscale 6), and PCA medication administration error (incorrect final programming). Increases in the number of interruptions were associated with significant increases in total task completion time ( p = .003). We also found increases in nurses' cognitive workload, nurse frustration, and PCA pump programming errors, but these increases were not statistically significant. Complex technology use permeates the acute care nursing practice environment. These results add new knowledge on nurses' clinical performance during PCA pump programming and high-risk medication administration.
Implementation of a web-based medication tracking system in a large academic medical center.
Calabrese, Sam V; Williams, Jonathan P
2012-10-01
Pharmacy workflow efficiencies achieved through the use of an electronic medication-tracking system are described. Medication dispensing turnaround times at the inpatient pharmacy of a large hospital were evaluated before and after transition from manual medication tracking to a Web-based tracking process involving sequential bar-code scanning and real-time monitoring of medication status. The transition was carried out in three phases: (1) a workflow analysis, including the identification of optimal points for medication scanning with hand-held wireless devices, (2) the phased implementation of an automated solution and associated hardware at a central dispensing pharmacy and three satellite locations, and (3) postimplementation data collection to evaluate the impact of the new tracking system and areas for improvement. Relative to the manual tracking method, electronic medication tracking allowed the capture of far more data points, enabling the pharmacy team to delineate the time required for each step of the medication dispensing process and to identify the steps most likely to involve delays. A comparison of baseline and postimplementation data showed substantial reductions in overall medication turnaround times with the use of the Web-based tracking system (time reductions of 45% and 22% at the central and satellite sites, respectively). In addition to more accurate projections and documentation of turnaround times, the Web-based tracking system has facilitated quality-improvement initiatives. Implementation of an electronic tracking system for monitoring the delivery of medications provided a comprehensive mechanism for calculating turnaround times and allowed the pharmacy to identify bottlenecks within the medication distribution system. Altering processes removed these bottlenecks and decreased delivery turnaround times.
NASA Astrophysics Data System (ADS)
Valluri, Monica; Vasiliev, Eugene; Bentz, Misty; Shen, Juntai
2018-04-01
Although 60% of disk galaxies are barred, stellar dynamical measurements of the masses of supermassive black holes (SMBH) in barred galaxies have always been obtained under the assumption that the bulges are axisymmetric. We use N-body simulations with self-consistently grown SMBHs in barred and unbarred galaxies to create a suite of mock Integral Field Spectrographic (IFS) datasets for galaxies with various observed orientations. We then apply an axisymmetric orbit superposition code to these mock IFS datasets to assess the reliability with which SMBH masses can be recovered. We also assess which disk and bar orientations give rise to biases. We use these simulations to assess whether or not existing SMBH measurements in barred galaxies are likely to be biased. We also present a brief preview of our JWST Early Release Science proposal to study the nuclear dynamics of nearby Seyfert I galaxy NGC 4151 with the NIRSpec Integral Field Spectrograph and describe how simulations of disk galaxies will used to create mock NIRSpec data to prepare for the real data.
The Code of Professional Responsibility and the College and University Lawyer
ERIC Educational Resources Information Center
Williams, Omer S. J.
1975-01-01
Background and history of the Canons of Ethics and Code of Professional Responsibility, adopted by the American Bar Association in 1969, are briefly outlined, and, as a case study, certain contexts in which ethical questions may arise for the college or university lawyer are discussed. Focus is on the lawyer as advisor. (JT)
Optimized Breech Location in the Harry Diamond Laboratories 4-Inch Gas Gun
1982-04-01
GAMA-iy*SQRrA BAR*(1-FRAC L~(GAMA-1))) IF INIT_G(BRL%)<=START TJ - THEN PRINT #BRL% USTNG FORM4$,INIT G(BRL%).VEL ELSE FLAG( BRU ) = 1 - 130 NEXT...CA 93041 COMMANDER DAVID W. TAYLOR NAVAL SHIP RESEARCH S DEVELOPMENT CENTER ATTN ELIZABETH DEMPSEY, CODE 534 ATTN PAUL GRANVILLE, CODE 581
[Development of operation patient security detection system].
Geng, Shu-Qin; Tao, Ren-Hai; Zhao, Chao; Wei, Qun
2008-11-01
This paper describes a patient security detection system developed with two dimensional bar codes, wireless communication and removal storage technique. Based on the system, nurses and correlative personnel check code wait operation patient to prevent the defaults. The tests show the system is effective. Its objectivity and currency are more scientific and sophisticated than current traditional method in domestic hospital.
Vann, Charles S.
2003-09-09
This small, inexpensive, non-contact laser sensor can detect the location of a retroreflective target in a relatively large volume and up to six degrees of position. The tracker's laser beam is formed into a plane of light which is swept across the space of interest. When the beam illuminates the retroreflector, some of the light returns to the tracker. The intensity, angle, and time of the return beam is measured to calculate the three dimensional location of the target. With three retroreflectors on the target, the locations of three points on the target are measured, enabling the calculation of all six degrees of target position. Until now, devices for three-dimensional tracking of objects in a large volume have been heavy, large, and very expensive. Because of the simplicity and unique characteristics of this tracker, it is capable of three-dimensional tracking of one to several objects in a large volume, yet it is compact, light-weight, and relatively inexpensive. Alternatively, a tracker produces a diverging laser beam which is directed towards a fixed position, and senses when a retroreflective target enters the fixed field of view. An optically bar coded target can be read by the tracker to provide information about the target. The target can be formed of a ball lens with a bar code on one end. As the target moves through the field, the ball lens causes the laser beam to scan across the bar code.
Stress-strain relationship of high-strength steel (HSS) reinforcing bars
NASA Astrophysics Data System (ADS)
Anggraini, Retno; Tavio, Raka, I. Gede Putu; Agustiar
2018-05-01
The introduction of High-Strength Steel (HSS) reinforcing bars in reinforced concrete members has gained much attention in recent years and led to many advantages such as construction timesaving. It is also more economical since it can reduce the amount of reinforcing steel bars used in concrete members which in turn alleviates the congestion of reinforcement. Up to present, the building codes, e.g. American Concrete Institute (ACI) 318M-14 and Standard National Indonesia (SNI) 2847:2013, still restrict the use of higher-strength steel reinforcing bars for concrete design up to Grade 420 MPa due to the possible suspected brittle behavior of concrete members. This paper evaluates the characteristics of stress-strain relationships of HSS bars if they are comparable to the characteristics of those of Grade 420 MPa. To achieve the objective of the study, a series of steel bars from various grades (420, 550, 650, and 700 MPa) was selected. Tensile tests of these steel samples were conducted under displacement-controlled mode to capture the complete stress-strain curves and particularly the post-yield response of the steel bars. The results indicate that all the steel bars tested had the actual yield strengths greater than the corresponding specified values. The stress-strain curves of HSS reinforcing bars (Grade 550, 650, and 700 MPa) performed slightly different characteristics with those of Grade 420 MPa.
Tensile strength/yield strength (TS/YS) ratios of high-strength steel (HSS) reinforcing bars
NASA Astrophysics Data System (ADS)
Tavio, Anggraini, Retno; Raka, I. Gede Putu; Agustiar
2018-05-01
The building codes such as American Concrete Institute (ACI) 318M-14 and Standard National Indonesia (SNI) 2847:2013 require that the ratio of tensile strength (TS) and yield strength (YS) should not less than 1.25. The requirement is based on the assumption that a capability of a structural member to develop inelastic rotation capacity is a function of the length of the yield region. This paper reports an investigation on various steel grades, namely Grades 420, 550, 650, and 700 MPa, to examine the impact of different TS/YS ratios if it is less or greater than the required value. Grades 550, 650, and 700 MPa were purposely selected with the intention to examine if these higher grades are still promising to be implemented in special structural systems since they are prohibited by the building codes for longitudinal reinforcement, whereas Grade 420 MPa bars are the maximum limit of yield strength of reinforcing bars that is allowable for longitudinal reinforcement of special structural systems. Tensile tests of these steel samples were conducted under displacement controlled mode to capture the complete stress-strain curves and particularly the post-yield response of the steel bars. From the study, it can be concluded that Grade 420 performed higher TS/YS ratios and they were able to reach up to more than 1.25. However, the High Strength Still (HSS) bars (Grades 550, 600, and 700 MPa) resulted in lower TS/YS ratios (less than 1.25) compared with those of Grade 420 MPa.
Spectroscopic diagnostics of tungsten-doped CH plasmas
NASA Astrophysics Data System (ADS)
Klapisch, M.; Colombant, D.; Lehecka, T.
1998-11-01
Spectra of CH with different concentrations of W dopant and laser intensities ( 2.5-10 x10^12 W/cm^2 ) were obtained at NRL with the Nike Laser. They were recorded in the 100-500 eV range with an XUV grating spectrometer. The hydrodynamic simulations are performed with the 1D code FAST1D(J. H. Gardner et al., Phys. Plasmas, 5, May (1998).) where non LTE effects are introduced by Busquet's model( M. Busquet, Phys. Fluids B, 5, 4191 (1993); M. Klapisch, A. Bar-Shalom, J. Oreg and D. Colombant, Phys. Plasmas, 5, May (1998).). They are then post-processed with TRANSPEC( O. Peyrusse, J. Quant. Spectrosc. Radiat. Transfer, 51, 281 (1994)), a time dependent collisional radiative code with radiation coupling. The necessary atomic data are obtained from the HULLAC code( M. Klapisch and A. Bar-Shalom, J. Quant. Spectrosc. Radiat. Transfer, 58, 687 (1997).). The post processing and diagnostics were performed on carbon lines and the results are compared with the experimental data.
A Wideband Circularly Polarized Pixelated Dielectric Resonator Antenna.
Trinh-Van, Son; Yang, Youngoo; Lee, Kang-Yoon; Hwang, Keum Cheol
2016-08-23
The design of a wideband circularly polarized pixelated dielectric resonator antenna using a real-coded genetic algorithm (GA) is presented for far-field wireless power transfer applications. The antenna consists of a dielectric resonator (DR) which is discretized into 8 × 8 grid DR bars. The real-coded GA is utilized to estimate the optimal heights of the 64 DR bars to realize circular polarization. The proposed antenna is excited by a narrow rectangular slot etched on the ground plane. A prototype of the proposed antenna is fabricated and tested. The measured -10 dB reflection and 3 dB axial ratio bandwidths are 32.32% (2.62-3.63 GHz) and 14.63% (2.85-3.30 GHz), respectively. A measured peak gain of 6.13 dBic is achieved at 3.2 GHz.
NASA Astrophysics Data System (ADS)
Zotos, Euaggelos E.; Jung, Christof
2018-01-01
The escape dynamics of the stars in a barred galaxy composed of a spherically symmetric central nucleus, a bar, a flat thin disc and a dark matter halo component is investigated by using a realistic three degrees of freedom (3-d.o.f.) dynamical model. Modern colour-coded diagrams are used for distinguishing between bounded and escaping motion. In addition, the smaller alignment index method is deployed for determining the regular, sticky or chaotic nature of bounded orbits. We reveal the basins of escape corresponding to the escape through the two symmetrical escape channels around the Lagrange points L2 and L3 and also we relate them with the corresponding distribution of the escape times of the orbits. Furthermore, we demonstrate how the stable manifolds, around the index-1 saddle points, accurately define the fractal basin boundaries observed in the colour-coded diagrams. The development scenario of the fundamental vertical Lyapunov periodic orbit is thoroughly explored for obtaining a more complete view of the unfolding of the singular behaviour of the dynamics at the cusp values of the parameters. Finally, we examine how the combination of the most important parameters of the bar (such as the semimajor axis and the angular velocity) influences the observed stellar structures (rings and spirals), which are formed by escaping stars guided by the invariant manifolds near the saddle points.
A new look at the simultaneous analysis and design of structures
NASA Technical Reports Server (NTRS)
Striz, Alfred G.
1994-01-01
The minimum weight optimization of structural systems, subject to strength and displacement constraints as well as size side constraints, was investigated by the Simultaneous ANalysis and Design (SAND) approach. As an optimizer, the code NPSOL was used which is based on a sequential quadratic programming (SQP) algorithm. The structures were modeled by the finite element method. The finite element related input to NPSOL was automatically generated from the input decks of such standard FEM/optimization codes as NASTRAN or ASTROS, with the stiffness matrices, at present, extracted from the FEM code ANALYZE. In order to avoid ill-conditioned matrices that can be encountered when the global stiffness equations are used as additional nonlinear equality constraints in the SAND approach (with the displacements as additional variables), the matrix displacement method was applied. In this approach, the element stiffness equations are used as constraints instead of the global stiffness equations, in conjunction with the nodal force equilibrium equations. This approach adds the element forces as variables to the system. Since, for complex structures and the associated large and very sparce matrices, the execution times of the optimization code became excessive due to the large number of required constraint gradient evaluations, the Kreisselmeier-Steinhauser function approach was used to decrease the computational effort by reducing the nonlinear equality constraint system to essentially a single combined constraint equation. As the linear equality and inequality constraints require much less computational effort to evaluate, they were kept in their previous form to limit the complexity of the KS function evaluation. To date, the standard three-bar, ten-bar, and 72-bar trusses have been tested. For the standard SAND approach, correct results were obtained for all three trusses although convergence became slower for the 72-bar truss. When the matrix displacement method was used, correct results were still obtained, but the execution times became excessive due to the large number of constraint gradient evaluations required. Using the KS function, the computational effort dropped, but the optimization seemed to become less robust. The investigation of this phenomenon is continuing. As an alternate approach, the code MINOS for the optimization of sparse matrices can be applied to the problem in lieu of the Kreisselmeier-Steinhauser function. This investigation is underway.
Integrated information systems for electronic chemotherapy medication administration.
Levy, Mia A; Giuse, Dario A; Eck, Carol; Holder, Gwen; Lippard, Giles; Cartwright, Julia; Rudge, Nancy K
2011-07-01
Chemotherapy administration is a highly complex and distributed task in both the inpatient and outpatient infusion center settings. The American Society of Clinical Oncology and the Oncology Nursing Society (ASCO/ONS) have developed standards that specify procedures and documentation requirements for safe chemotherapy administration. Yet paper-based approaches to medication administration have several disadvantages and do not provide any decision support for patient safety checks. Electronic medication administration that includes bar coding technology may provide additional safety checks, enable consistent documentation structure, and have additional downstream benefits. We describe the specialized configuration of clinical informatics systems for electronic chemotherapy medication administration. The system integrates the patient registration system, the inpatient order entry system, the pharmacy information system, the nursing documentation system, and the electronic health record. We describe the process of deploying this infrastructure in the adult and pediatric inpatient oncology, hematology, and bone marrow transplant wards at Vanderbilt University Medical Center. We have successfully adapted the system for the oncology-specific documentation requirements detailed in the ASCO/ONS guidelines for chemotherapy administration. However, several limitations remain with regard to recording the day of treatment and dose number. Overall, the configured systems facilitate compliance with the ASCO/ONS guidelines and improve the consistency of documentation and multidisciplinary team communication. Our success has prompted us to deploy this infrastructure in our outpatient chemotherapy infusion centers, a process that is currently underway and that will require a few unique considerations.
Prevalence of and Differences in Salad Bar Implementation in Rural Versus Urban Arizona Schools.
Blumenschine, Michelle; Adams, Marc; Bruening, Meg
2018-03-01
Rural children consume more calories per day on average than urban children, and they are less likely to consume fruit. Self-service salad bars have been proposed as an effective approach to better meet the National School Lunch Program's fruit and vegetable recommendations. No studies have examined how rural and urban schools differ in the implementation of school salad bars. To compare the prevalence of school-lunch salad bars and differences in implementation between urban and rural Arizona schools. Secondary analysis of a cross-sectional web-based survey. School nutrition managers (N=596) in the state of Arizona. National Center for Education Statistics locale codes defined rural and urban classifications. Barriers to salad bar implementation were examined among schools that have never had, once had, and currently have a school salad bar. Promotional practices were examined among schools that once had and currently have a school salad bar. Generalized estimating equation models were used to compare urban and rural differences in presence and implementation of salad bars, adjusting for school-level demographics and the clustering of schools within districts. After adjustment, the prevalence of salad bars did not differ between urban and rural schools (46.9%±4.3% vs 46.8%±8.5%, respectively). Rural schools without salad bars more often reported perceived food waste and cost of produce as barriers to implementing salad bars, and funding was a necessary resource for offering a salad bar in the future, as compared with urban schools (P<0.05). No other geographic differences were observed in reported salad bar promotion, challenges, or resources among schools that currently have or once had a salad bar. After adjustment, salad bar prevalence, implementation practices, and concerns are similar across geographic settings. Future research is needed to investigate methods to address cost and food waste concerns in rural areas. Copyright © 2018 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
Numerical Study on Deflection Behaviour of Concrete Beams Reinforced with GFRP Bars
NASA Astrophysics Data System (ADS)
Mohamed, Osama A.; Khattab, Rania; Hawat, Waddah Al
2017-10-01
Fiber-Reinforced Polymer (FRP) bars are gaining popularity as sustainable alternatives to conventional reinforcing steel bars in reinforced concrete applications. The production of FRP bars has lower environmental impact compared to steel reinforcing bars. In addition, the non-corroding FRP materials can potentially decrease the cost or need for maintenance of reinforced concrete structural elements, especially in harsh environmental conditions that can impact both concrete and reinforcement. FRP bars offer additional favourable properties including high tensile strength and low unit weight. However, the mechanical properties of FRP bars can lead to large crack widths and deflections. The objective of this study is to investigate the deflection behaviour of concrete beams reinforced with Glass FRP (GFRP) bars as a longitudinal main reinforcement. Six concrete beams reinforced with GFRP bars were modelled using the finite element computer program ANSYS. The main variable considered in the study is the reinforcement ratio. The deflection equations in current North American codes including ACI 440.1R-06, ACI 440.1R-15 and CSA S806-12 are used to compute deflections, and these are compared to numerical results. It was concluded in this paper that deflections predicted by ACI 440.1R-06 equations are lower than the numerical analysis results while ACI 440.1R-15 is in agreement with numerical analysis with tendency to be conservative. The values of deflections estimated by CSA S806-12 formulas are consistent with results of numerical analysis.
Custodial Management in the Information Age.
ERIC Educational Resources Information Center
Harris, Jim, Sr.
1999-01-01
Explains how computerizing the custodial department can be achieved through bar coding, hand-held readers, and the appropriate software packages. Software programs that aid cleaning management, track assets, and manage stock are discussed. (GR)
Radio Frequency Identification Applications in Pavements
DOT National Transportation Integrated Search
2014-08-01
Radio frequency identification (RFID) technology is widely used for inventory control, tool and material tracking, and other similar applications where line-of-sight optical bar codes are inconvenient or impractical. Several applications of RFID tech...
48 CFR 1852.245-78 - Physical inventory of capital personal property.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., responsibility for maintenance, or responsibility for posting to the property record. The Contractor may request... for property identification, such as a laser bar-code reader or radio frequency identification reader...
48 CFR 1852.245-78 - Physical inventory of capital personal property.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., responsibility for maintenance, or responsibility for posting to the property record. The Contractor may request... for property identification, such as a laser bar-code reader or radio frequency identification reader...
48 CFR 1852.245-78 - Physical inventory of capital personal property.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., responsibility for maintenance, or responsibility for posting to the property record. The Contractor may request... for property identification, such as a laser bar-code reader or radio frequency identification reader...
Du, Ping; Li, Hongxia; Cao, Wei
2009-07-15
A novel and sensitive sandwich electrochemical biosensor based on the amplification of magnetic microbeads and Au nanoparticles (NPs) modified with bio bar code and PbS nanoparticles was constructed in the present work. In this method, the magnetic microspheres were coated with 4 layers polyelectrolytes in order to increase carboxyl groups on the surface of the magnetic microbeads, which enhanced the amount of the capture DNA. The amino-functionalized capture DNA on the surface of magnetic microbeads hybridized with one end of target DNA, the other end of which was hybridized with signal DNA probe labelled with Au NPs on the terminus. The Au NPs were modified with bio bar code and the PbS NPs were used as a marker for identifying the target oligoncleotide. The modification of magnetic microbeads could immobilize more amino-group terminal capture DNA, and the bio bar code could increase the amount of Au NPs that combined with the target DNA. The detection of lead ions performed by anodic stripping voltammetry (ASV) technology further improved the sensitivity of the biosensor. As a result, the present DNA biosensor showed good selectivity and sensitivity by the combined amplification. Under the optimum conditions, the linear relationship with the concentration of the target DNA was ranging from 2.0 x 10(-14) M to 1.0 x 10(-12)M and a detection limit as low as 5.0 x 10(-15)M was obtained.
Matus, Bethany A; Bridges, Kayla M; Logomarsino, John V
2018-06-21
Individualized feeding care plans and safe handling of milk (human or formula) are critical in promoting growth, immune function, and neurodevelopment in the preterm infant. Feeding errors and disruptions or limitations to feeding processes in the neonatal intensive care unit (NICU) are associated with negative safety events. Feeding errors include contamination of milk and delivery of incorrect or expired milk and may result in adverse gastrointestinal illnesses. The purpose of this review was to evaluate the effect(s) of centralized milk preparation, use of trained technicians, use of bar code-scanning software, and collaboration between registered dietitians and registered nurses on feeding safety in the NICU. A systematic review of the literature was completed, and 12 articles were selected as relevant to search criteria. Study quality was evaluated using the Downs and Black scoring tool. An evaluation of human studies indicated that the use of centralized milk preparation, trained technicians, bar code-scanning software, and possible registered dietitian involvement decreased feeding-associated error in the NICU. A state-of-the-art NICU includes a centralized milk preparation area staffed by trained technicians, care supported by bar code-scanning software, and utilization of a registered dietitian to improve patient safety. These resources will provide nurses more time to focus on nursing-specific neonatal care. Further research is needed to evaluate the impact of factors related to feeding safety in the NICU as well as potential financial benefits of these quality improvement opportunities.
Automatic generation of user material subroutines for biomechanical growth analysis.
Young, Jonathan M; Yao, Jiang; Ramasubramanian, Ashok; Taber, Larry A; Perucchio, Renato
2010-10-01
The analysis of the biomechanics of growth and remodeling in soft tissues requires the formulation of specialized pseudoelastic constitutive relations. The nonlinear finite element analysis package ABAQUS allows the user to implement such specialized material responses through the coding of a user material subroutine called UMAT. However, hand coding UMAT subroutines is a challenge even for simple pseudoelastic materials and requires substantial time to debug and test the code. To resolve this issue, we develop an automatic UMAT code generation procedure for pseudoelastic materials using the symbolic mathematics package MATHEMATICA and extend the UMAT generator to include continuum growth. The performance of the automatically coded UMAT is tested by simulating the stress-stretch response of a material defined by a Fung-orthotropic strain energy function, subject to uniaxial stretching, equibiaxial stretching, and simple shear in ABAQUS. The MATHEMATICA UMAT generator is then extended to include continuum growth by adding a growth subroutine to the automatically generated UMAT. The MATHEMATICA UMAT generator correctly derives the variables required in the UMAT code, quickly providing a ready-to-use UMAT. In turn, the UMAT accurately simulates the pseudoelastic response. In order to test the growth UMAT, we simulate the growth-based bending of a bilayered bar with differing fiber directions in a nongrowing passive layer. The anisotropic passive layer, being topologically tied to the growing isotropic layer, causes the bending bar to twist laterally. The results of simulations demonstrate the validity of the automatically coded UMAT, used in both standardized tests of hyperelastic materials and for a biomechanical growth analysis.
Liu, Ruimei; Feng, Feng; Chen, Guolin; Liu, Zhimin; Xu, Zhigang
2016-07-01
This study reports the development of a novel dummy template molecularly imprinted polymer (MIP)-coated barbell-shaped stir bar. The MIP stir bar coatings were prepared by using 2,2-bis(4-hydroxyphenyl)butane (BPB), 4,4'-dihydroxydiphenylmethane (BPF), 4-tert-butylphenol (PTBP), and tetrabromobisphenol A (TBBA) as dummy templates using a capillary in situ polymerization method. Uniform coatings can be prepared controllably. The method is simple, easy, and reproducible. The barbell-shaped stir bar was developed by using medical silicone tubes as wheels. The wheels could be removed and reinstalled when necessary; therefore, the barbell-shaped stir bar was easy to disassemble and reassemble. The novel MIP-coated stir bar showed good selectivity for the target analyte, bisphenol A (BPA). The established method is selective and sensitive with a lower detection limit for BPA of 0.003 μg/L. The dummy template MIP-coated stir bar is suitable for trace BPA analysis in real environmental water samples without template leakage. The novel stir bar can be used at least 100 times.
Learning Disabilities, Professionalism, and the Practice of Medical Education.
ERIC Educational Resources Information Center
Hafferty, Frederic W.; Gibson, Gary G.
2003-01-01
Examines arguments by Little in the preceding article that a successful legal suit for accommodations on a state bar exam is generalizable to learning disabilities and medical education. Explores the legitimacy accorded to academic accommodations in medical education. Asserts that medical schools have a social responsibility to shift their…
40 CFR 51.362 - Motorist compliance enforcement program oversight.
Code of Federal Regulations, 2010 CFR
2010-07-01
... collection through the use of automatic data capture systems such as bar-code scanners or optical character... determination of compliance through parking lot surveys, road-side pull-overs, or other in-use vehicle...
40 CFR 51.362 - Motorist compliance enforcement program oversight.
Code of Federal Regulations, 2011 CFR
2011-07-01
... collection through the use of automatic data capture systems such as bar-code scanners or optical character... determination of compliance through parking lot surveys, road-side pull-overs, or other in-use vehicle...
Medication errors in the emergency department: a systems approach to minimizing risk.
Peth, Howard A
2003-02-01
Adverse drug events caused by medication errors represent a common cause of patient injury in the practice of medicine. Many medication errors are preventable and hence particularly tragic when they occur, often with serious consequences. The enormous increase in the number of available drugs on the market makes it all but impossible for physicians, nurses, and pharmacists to possess the knowledge base necessary for fail-safe medication practice. Indeed, the greatest single systemic factor associated with medication errors is a deficiency in the knowledge requisite to the safe use of drugs. It is vital that physicians, nurses, and pharmacists have at their immediate disposal up-to-date drug references. Patients presenting for care in EDs are usually unfamiliar to their EPs and nurses, and the unique patient factors affecting medication response and toxicity are obscured. An appropriate history, physical examination, and diagnostic workup will assist EPs, nurses, and pharmacists in selecting the safest and most optimum therapeutic regimen for each patient. EDs deliver care "24/7" and are open when valuable information resources, such as hospital pharmacists and previously treating physicians, may not be available for consultation. A systems approach to the complex problem of medication errors will help emergency clinicians eliminate preventable adverse drug events and achieve a goal of a zero-defects system, in which medication errors are a thing of the past. New developments in information technology and the advent of electronic medical records with computerized physician order entry, ward-based clinical pharmacists, and standardized bar codes promise substantial reductions in the incidence of medication errors and adverse drug events. ED patients expect and deserve nothing less than the safest possible emergency medicine service.
Nuss bar migrations: occurrence and classification.
Binkovitz, Lauren E; Zendejas, Benjamin; Moir, Christopher R; Binkovitz, Larry A
2016-12-01
Pectus excavatum results from dorsal deviation of the sternum causing narrowing of the anterior-posterior diameter of the chest. It can result in significant cosmetic deformities and cardiopulmonary compromise if severe. The Nuss procedure is a minimally invasive technique that involves placing a thin horizontally oriented metal bar below the dorsal sternal apex for correction of the pectus deformity. To identify the frequency and types of Nuss bar migrations, to present a new categorization of bar migrations, and to present examples of true migrations and pseudomigrations. We retrospectively reviewed the electronic medical records and all pertinent radiologic studies of 311 pediatric patients who underwent a Nuss procedure. We evaluated the frequency and type of bar migrations. Bar migration was demonstrated in 23 of 311 patients (7%) and occurred within a mean period of 26 days after surgery. Bar migrations were subjectively defined as deviation of the bar from the position demonstrated on the immediate postoperative radiographs and categorized as superior, inferior, rotation, lateral or flipped using a new classification system. Sixteen of the 23 migrations required re-operation. Nuss bar migration can be diagnosed with careful evaluation of serial radiographs. Nuss bar migration has a wide variety of appearances and requires exclusion of pseudomigration resulting from changes in patient positioning between radiologic examinations.
Some conservative estimates in quantum cryptography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Molotkov, S. N.
2006-08-15
Relationship is established between the security of the BB84 quantum key distribution protocol and the forward and converse coding theorems for quantum communication channels. The upper bound Q{sub c} {approx} 11% on the bit error rate compatible with secure key distribution is determined by solving the transcendental equation H(Q{sub c})=C-bar({rho})/2, where {rho} is the density matrix of the input ensemble, C-bar({rho}) is the classical capacity of a noiseless quantum channel, and H(Q) is the capacity of a classical binary symmetric channel with error rate Q.
Samaranayake, N R; Cheung, S T D; Chui, W C M; Cheung, B M Y
2012-12-01
Healthcare technology is meant to reduce medication errors. The objective of this study was to assess unintended errors related to technologies in the medication use process. Medication incidents reported from 2006 to 2010 in a main tertiary care hospital were analysed by a pharmacist and technology-related errors were identified. Technology-related errors were further classified as socio-technical errors and device errors. This analysis was conducted using data from medication incident reports which may represent only a small proportion of medication errors that actually takes place in a hospital. Hence, interpretation of results must be tentative. 1538 medication incidents were reported. 17.1% of all incidents were technology-related, of which only 1.9% were device errors, whereas most were socio-technical errors (98.1%). Of these, 61.2% were linked to computerised prescription order entry, 23.2% to bar-coded patient identification labels, 7.2% to infusion pumps, 6.8% to computer-aided dispensing label generation and 1.5% to other technologies. The immediate causes for technology-related errors included, poor interface between user and computer (68.1%), improper procedures or rule violations (22.1%), poor interface between user and infusion pump (4.9%), technical defects (1.9%) and others (3.0%). In 11.4% of the technology-related incidents, the error was detected after the drug had been administered. A considerable proportion of all incidents were technology-related. Most errors were due to socio-technical issues. Unintended and unanticipated errors may happen when using technologies. Therefore, when using technologies, system improvement, awareness, training and monitoring are needed to minimise medication errors. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Gnjidic, Danijela; Pearson, Sallie-Anne; Hilmer, Sarah N; Basilakis, Jim; Schaffer, Andrea L; Blyth, Fiona M; Banks, Emily
2015-03-30
Increasingly, automated methods are being used to code free-text medication data, but evidence on the validity of these methods is limited. To examine the accuracy of automated coding of previously keyed in free-text medication data compared with manual coding of original handwritten free-text responses (the 'gold standard'). A random sample of 500 participants (475 with and 25 without medication data in the free-text box) enrolled in the 45 and Up Study was selected. Manual coding involved medication experts keying in free-text responses and coding using Anatomical Therapeutic Chemical (ATC) codes (i.e. chemical substance 7-digit level; chemical subgroup 5-digit; pharmacological subgroup 4-digit; therapeutic subgroup 3-digit). Using keyed-in free-text responses entered by non-experts, the automated approach coded entries using the Australian Medicines Terminology database and assigned corresponding ATC codes. Based on manual coding, 1377 free-text entries were recorded and, of these, 1282 medications were coded to ATCs manually. The sensitivity of automated coding compared with manual coding was 79% (n = 1014) for entries coded at the exact ATC level, and 81.6% (n = 1046), 83.0% (n = 1064) and 83.8% (n = 1074) at the 5, 4 and 3-digit ATC levels, respectively. The sensitivity of automated coding for blank responses was 100% compared with manual coding. Sensitivity of automated coding was highest for prescription medications and lowest for vitamins and supplements, compared with the manual approach. Positive predictive values for automated coding were above 95% for 34 of the 38 individual prescription medications examined. Automated coding for free-text prescription medication data shows very high to excellent sensitivity and positive predictive values, indicating that automated methods can potentially be useful for large-scale, medication-related research.
Integrated Information Systems for Electronic Chemotherapy Medication Administration
Levy, Mia A.; Giuse, Dario A.; Eck, Carol; Holder, Gwen; Lippard, Giles; Cartwright, Julia; Rudge, Nancy K.
2011-01-01
Introduction: Chemotherapy administration is a highly complex and distributed task in both the inpatient and outpatient infusion center settings. The American Society of Clinical Oncology and the Oncology Nursing Society (ASCO/ONS) have developed standards that specify procedures and documentation requirements for safe chemotherapy administration. Yet paper-based approaches to medication administration have several disadvantages and do not provide any decision support for patient safety checks. Electronic medication administration that includes bar coding technology may provide additional safety checks, enable consistent documentation structure, and have additional downstream benefits. Methods: We describe the specialized configuration of clinical informatics systems for electronic chemotherapy medication administration. The system integrates the patient registration system, the inpatient order entry system, the pharmacy information system, the nursing documentation system, and the electronic health record. Results: We describe the process of deploying this infrastructure in the adult and pediatric inpatient oncology, hematology, and bone marrow transplant wards at Vanderbilt University Medical Center. We have successfully adapted the system for the oncology-specific documentation requirements detailed in the ASCO/ONS guidelines for chemotherapy administration. However, several limitations remain with regard to recording the day of treatment and dose number. Conclusion: Overall, the configured systems facilitate compliance with the ASCO/ONS guidelines and improve the consistency of documentation and multidisciplinary team communication. Our success has prompted us to deploy this infrastructure in our outpatient chemotherapy infusion centers, a process that is currently underway and that will require a few unique considerations. PMID:22043185
Auto identification technology and its impact on patient safety in the Operating Room of the Future.
Egan, Marie T; Sandberg, Warren S
2007-03-01
Automatic identification technologies, such as bar coding and radio frequency identification, are ubiquitous in everyday life but virtually nonexistent in the operating room. User expectations, based on everyday experience with automatic identification technologies, have generated much anticipation that these systems will improve readiness, workflow, and safety in the operating room, with minimal training requirements. We report, in narrative form, a multi-year experience with various automatic identification technologies in the Operating Room of the Future Project at Massachusetts General Hospital. In each case, the additional human labor required to make these ;labor-saving' technologies function in the medical environment has proved to be their undoing. We conclude that while automatic identification technologies show promise, significant barriers to realizing their potential still exist. Nevertheless, overcoming these obstacles is necessary if the vision of an operating room of the future in which all processes are monitored, controlled, and optimized is to be achieved.
Digital Equivalent Data System for XRF Labeling of Objects
NASA Technical Reports Server (NTRS)
Schramm, Harry F.; Kaiser, Bruce
2005-01-01
A digital equivalent data system (DEDS) is a system for identifying objects by means of the x-ray fluorescence (XRF) spectra of labeling elements that are encased in or deposited on the objects. As such, a DEDS is a revolutionary new major subsystem of an XRF system. A DEDS embodies the means for converting the spectral data output of an XRF scanner to an ASCII alphanumeric or barcode label that can be used to identify (or verify the assumed or apparent identity of) an XRF-scanned object. A typical XRF spectrum of interest contains peaks at photon energies associated with specific elements on the Periodic Table (see figure). The height of each spectral peak above the local background spectral intensity is proportional to the relative abundance of the corresponding element. Alphanumeric values are assigned to the relative abundances of the elements. Hence, if an object contained labeling elements in suitably chosen proportions, an alphanumeric representation of the object could be extracted from its XRF spectrum. The mixture of labeling elements and for reading the XRF spectrum would be compatible with one of the labeling conventions now used for bar codes and binary matrix patterns (essentially, two-dimensional bar codes that resemble checkerboards). A further benefit of such compatibility is that it would enable the conversion of the XRF spectral output to a bar or matrix-coded label, if needed. In short, a process previously used only for material composition analysis has been reapplied to the world of identification. This new level of verification is now being used for "authentication."
Wang, Lanlan; Ma, Rongna; Jiang, Liushan; Jia, Liping; Jia, Wenli; Wang, Huaisheng
2017-06-15
A novel dual-signal ratiometric electrochemical aptasensor for highly sensitive and selective detection of thrombin has been designed on the basis of signal-on and signal-off strategy. Ferrocene labeled hairpin probe (Fc-HP), thrombin aptamer and methyl blue labeled bio-bar-coded AuNPs (MB-P3-AuNPs) were rationally introduced for the construction of the assay platform, which combined the advantages of the recognition of aptamer, the amplification of bio-bar-coded nanoprobe, and the ratiometric signaling readout. In the presence of thrombin, the interaction between thrombin and the aptamer leads to the departure of MB-P3-AuNPs from the sensing interface, and the conformation of the single stranded Fc-HP to a hairpin structure to take the Fc confined near the electrode surface. Such conformational changes resulted in the oxidation current of Fc increased and that of MB decreased. Therefore, the recognition event of the target can be dual-signal ratiometric electrochemical readout in both the "signal-off" of MB and the "signal-on" of Fc. The proposed strategy showed a wide linear detection range from 0.003 to 30nM with a detection limit of 1.1 pM. Moreover, it exhibits good performance of excellent selectivity, good stability, and acceptable fabrication reproducibility. By changing the recognition probe, this protocol could be easily expanded into the detection of other targets, showing promising potential applications in disease diagnostics and bioanalysis. Copyright © 2016. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Nagasaka, Y.; Brimacombe, J. K.; Hawbolt, E. B.; Samarasekera, I. V.; Hernandez-Morales, B.; Chidiac, S. E.
1993-04-01
A mathematical model, based on the finite-element technique and incorporating thermo-elasto-plastic behavior during the water spray quenching of steel, has been developed. In the model, the kinetics of diffusion-dependent phase transformation and martensitic transformation have been coupled with the transient heat flow to predict the microstructural evolution of the steel. Furthermore, an elasto-plastic constitutive relation has been applied to calculate internal stresses resulting from phase changes as well as temperature variation. The computer code has been verified for internal consistency with previously published results for pure iron bars. The model has been applied to the water spray quenching of two grades of steel bars, 1035 carbon and nickel-chromium alloyed steel; the calculated temperature, hardness, distortion, and residual stresses in the bars agreed well with experimental measurements. The results show that the phase changes occurring during this process affect the internal stresses significantly and must be included in the thermomechanical model.
Predicting Morphology of Polymers Using Mesotek+
2010-02-01
file is then produced for Mesotek+ to reproduce the phase behavior for an experimental system of poly (styrene-b- isoprene ) in the solvent tetradecane...theoretical code 3a and (b) experimental code 3b. .....6 Figure 3. Results from 40/60 volume styrene-b- isoprene + tetradecane using gnuplot: A...styrene volume fraction, B) isoprene volume fraction, and C) tetradecane volume fraction. The color bar to the right of each plot indicates how the
Matsuo, Toshihiko; Gochi, Akira; Hirakawa, Tsuyoshi; Ito, Tadashi; Kohno, Yoshihisa
2010-10-01
General electronic medical records systems remain insufficient for ophthalmology outpatient clinics from the viewpoint of dealing with many ophthalmic examinations and images in a large number of patients. Filing systems for documents and images by Yahgee Document View (Yahgee, Inc.) were introduced on the platform of general electronic medical records system (Fujitsu, Inc.). Outpatients flow management system and electronic medical records system for ophthalmology were constructed. All images from ophthalmic appliances were transported to Yahgee Image by the MaxFile gateway system (P4 Medic, Inc.). The flow of outpatients going through examinations such as visual acuity testing were monitored by the list "Ophthalmology Outpatients List" by Yahgee Workflow in addition to the list "Patients Reception List" by Fujitsu. Patients' identification number was scanned with bar code readers attached to ophthalmic appliances. Dual monitors were placed in doctors' rooms to show Fujitsu Medical Records on the left-hand monitor and ophthalmic charts of Yahgee Document on the right-hand monitor. The data of manually-inputted visual acuity, automatically-exported autorefractometry and non-contact tonometry on a new template, MaxFile ED, were again automatically transported to designated boxes on ophthalmic charts of Yahgee Document. Images such as fundus photographs, fluorescein angiograms, optical coherence tomographic and ultrasound scans were viewed by Yahgee Image, and were copy-and-pasted to assigned boxes on the ophthalmic charts. Ordering such as appointments, drug prescription, fees and diagnoses input, central laboratory tests, surgical theater and ward room reservations were placed by functions of the Fujitsu electronic medical records system. The combination of the Fujitsu electronic medical records and Yahgee Document View systems enabled the University Hospital to examine the same number of outpatients as prior to the implementation of the computerized filing system.
A Pharmacy Blueprint for Electronic Medical Record Implementation Success
Bach, David S.; Risko, Kenneth R.; Farber, Margo S.; Polk, Gregory J.
2015-01-01
Objective: Implementation of an integrated, electronic medical record (EMR) has been promoted as a means of improving patient safety and quality. While there are a few reports of such processes that incorporate computerized prescriber order entry, pharmacy verification, an electronic medication administration record (eMAR), point-of-care barcode scanning, and clinical decision support, there are no published reports on how a pharmacy department can best participate in implementing such a process across a multihospital health care system. Method: This article relates the experience of the design, build, deployment, and maintenance of an integrated EMR solution from the pharmacy perspective. It describes a 9-month planning and build phase and the subsequent rollout at 8 hospitals over the following 13 months. Results: Key components to success are identified, as well as a set of guiding principles that proved invaluable in decision making and dispute resolution. Labor/personnel requirements for the various stages of the process are discussed, as are issues involving medication workflow analysis, drug database considerations, the development of clinical order sets, and incorporation of bar-code scanning of medications. Recommended implementation and maintenance strategies are presented, and the impact of EMR implementation on the pharmacy practice model and revenue analysis are examined. Conclusion: Adherence to the principles and practices outlined in this article can assist pharmacy administrators and clinicians during all medication-related phases of the development, implementation, and maintenance of an EMR solution. Furthermore, review and incorporation of some or all of practices presented may help ease the process and ensure its success. PMID:26405340
High power laser diodes at 14xx nm wavelength range for industrial and medical applications
NASA Astrophysics Data System (ADS)
Telkkälä, Jarkko; Boucart, Julien; Krejci, Martin; Crum, Trevor; Lichtenstein, Norbert
2014-03-01
We report on the development of the latest generation of high power laser diodes at 14xx nm wavelength range suitable for industrial applications such as plastics welding and medical applications including acne treatment, skin rejuvenation and surgery. The paper presents the newest chip generation developed at II-VI Laser Enterprise, increasing the output power and the power conversion efficiency while retaining the reliability of the initial design. At an emission wavelength around 1440 nm we applied the improved design to a variety of assemblies exhibiting maximum power values as high as 7 W for broad-area single emitters. For 1 cm wide bars on conductive coolers and for bars on active micro channel coolers we have obtained 50 W and 72 W in continuous wave (cw) operation respectively. The maximum power measured for a 1 cm bar operated with 50 μs pulse width and 0.01% duty cycle was 184 W, demonstrating the potential of the chip design for optimized cooling. Power conversion efficiency values as high as 50% for a single emitter device and over 40% for mounted bars have been demonstrated, reducing the required power budget to operate the devices. Both active and conductive bar assembly configurations show polarization purity greater than 98%. Life testing has been conducted at 95 A, 50% duty cycle and 0.5 Hz hard pulsed operation for bars which were soldered to conductive copper CS mounts using our hard solder technology. The results after 5500 h, or 10 million "on-off" cycles show stable operation.
Room temperature high power mid-IR diode laser bars for atmospheric sensing applications
NASA Astrophysics Data System (ADS)
Crump, Paul; Patterson, Steve; Dong, Weimin; Grimshaw, Mike; Wang, Jun; Zhang, Shiguo; Elim, Sandrio; Bougher, Mike; Patterson, Jason; Das, Suhit; Wise, Damian; Matson, Triston; Balsley, David; Bell, Jake; DeVito, Mark; Martinsen, Rob
2007-04-01
Peak CW optical power from single 1-cm diode laser bars is advancing rapidly across all commercial wavelengths and the available range of emission wavelengths also continues to increase. Both high efficiency ~ 50% and > 100-W power InP-based CW bars have been available in bar format around 1500-nm for some time, as required for eye-safe illuminators and for pumping Er-YAG crystals. There is increasing demand for sources at longer wavelengths. Specifically, 1900-nm sources can be used to pump Holmium doped YAG crystals, to produce 2100-nm emission. Emission near 2100-nm is attractive for free-space communications and range-finding applications as the atmosphere has little absorption at this wavelength. Diode lasers that emit at 2100-nm could eliminate the need for the use of a solid-state laser system, at significant cost savings. 2100-nm sources can also be used as pump sources for Thulium doped solid-state crystals to reach even longer wavelengths. In addition, there are several promising medical applications including dental applications such as bone ablation and medical procedures such as opthamology. These long wavelength sources are also key components in infra-red-counter-measure systems. We have extended our high performance 1500-nm material to longer wavelengths through optimization of design and epitaxial growth conditions and report peak CW output powers from single 1-cm diode laser bars of 37W at 1910-nm and 25W at 2070-nm. 1-cm bars with 20% fill factor were tested under step-stress conditions up to 110-A per bar without failure, confirming reasonable robustness of this technology. Stacks of such bars deliver high powers in a collimated beam suitable for pump applications. We demonstrate the natural spectral width of ~ 18nm of these laser bars can be reduced to < 3-nm with use of an external Volume Bragg Grating, as required for pump applications. We review the developments required to reach these powers, latest advances and prospects for longer wavelength, higher power and higher efficiency.
The Canadian Medical Association Code of Ethics 1868 to 1996: a primer for medical educators.
Brownell, A Keith W; Brownell, Elizabeth
2002-06-01
The Canadian Medical Association's (CMA) Code of Ethics applies to all physicians, residents, and medical students in Canada. Learning about the code must be a part of every physician's education, and keeping current with it must be a part of every physician's continuing medical education. This article, based on a review of the 19 CMA codes of ethics issued from 1868 to 1996, shows how deeply the Code of Ethics is tied to the past, highlights those topics that have been part of every version, and demonstrates how the code changed over time. This article should assist medical educators as they develop teaching material on codes of medical ethics, and would be of interest to practising physicians.
Technological Enhancements for Personal Computers
1992-03-01
quicker order processing , shortening the time required to obtain critical spare parts. 31 Customer service and spare parts tracking are facilitated by...cards speed up order processing and filing. Bar code readers speed inventory control processing. D. DEPLOYMENT PLANNING. Many units with high mobility
25 CFR 542.8 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2011 CFR
2011-04-01
... microchip reader, the reader shall be tested periodically to determine that it is correctly reading the bar code or microchip. (iii) If the electronic equipment returns a voucher or a payment slip to the player...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Computer Reader finalization costs, cost per image, and Remote Bar Code Sorter leakage; (8) Percentage of... processing units costs for Carrier Route, High Density, and Saturation mail; (j) Mail processing unit costs...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Computer Reader finalization costs, cost per image, and Remote Bar Code Sorter leakage; (8) Percentage of... processing units costs for Carrier Route, High Density, and Saturation mail; (j) Mail processing unit costs...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Computer Reader finalization costs, cost per image, and Remote Bar Code Sorter leakage; (8) Percentage of... processing units costs for Carrier Route, High Density, and Saturation mail; (j) Mail processing unit costs...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Computer Reader finalization costs, cost per image, and Remote Bar Code Sorter leakage; (8) Percentage of... processing units costs for Carrier Route, High Density, and Saturation mail; (j) Mail processing unit costs...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Computer Reader finalization costs, cost per image, and Remote Bar Code Sorter leakage; (8) Percentage of... processing units costs for Carrier Route, High Density, and Saturation mail; (j) Mail processing unit costs...
A tool for improving the Web accessibility of visually handicapped persons.
Fujiki, Tadayoshi; Hanada, Eisuke; Yamada, Tomomi; Noda, Yoshihiro; Antoku, Yasuaki; Nakashima, Naoki; Nose, Yoshiaki
2006-04-01
Abstract Much has been written concerning the difficulties faced by visually handicapped persons when they access the internet. To solve some of the problems and to make web pages more accessible, we developed a tool we call the "Easy Bar," which works as a toolbar on the web browser. The functions of the Easy Bar are to change the size of web texts and images, to adjust the color, and to clear cached data that is automatically saved by the web browser. These functions are executed with ease by clicking buttons and operating a pull-down list. Since the icons built into Easy Bar are quite large, it is not necessary for the user to deal with delicate operations. The functions of Easy Bar run on any web page without increasing the processing time. For the visually handicapped, Easy Bar would contribute greatly to improved web accessibility to medical information.
Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study
Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung
2016-01-01
Background To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. Objective In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. Methods We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants’ opinions regarding patient safety, timeliness, efficiency, and usability were recorded. Results In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Conclusions Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use. PMID:27784649
Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study.
Lee, Guna; Lee, Yura; Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung; Lee, Jae-Ho
2016-10-26
To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants' opinions regarding patient safety, timeliness, efficiency, and usability were recorded. In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use.
NASA Technical Reports Server (NTRS)
2004-01-01
Two-dimensional data matrix symbols, which contain encoded letters and numbers, are permanently etched on items for identification. They can store up to 100 times more information than traditional bar codes. While the symbols provide several advantages over bar codes, once they are covered by paint they can no longer be read by optical scanners. Since most products are painted eventually, this presents a problem for industries relying on the symbols for identification and tracking. In 1987, NASA s Marshall Space Flight Center began studying direct parts marking with matrix symbols in order to track millions of Space Shuttle parts. Advances in the technology proved that by incorporating magnetic properties into the paints, inks, and pastes used to apply the matrix symbols, the codes could be read by a magnetic scanner even after being covered with paint or other coatings. NASA received a patent for such a scanner in 1998, but the system it used for development was not portable and was too costly. A prototype was needed as a lead-in to a production model. In the summer of 2000, NASA began seeking companies to build a hand-held scanner that would detect the Read Through Paint data matrix identification marks containing magnetic materials through coatings.
[The evolution of the Italian Code of Medical Deontology: a historical-epistemological perspective].
Conti, A A
The Italian Code of Medical Deontology is a set of self-discipline rules prefixed by the medical profession, that are mandatory for the members of the medical registers, who must conform to these rules. The history of the Italian Code of Medical Deontology dates back to the beginning of the twentieth century. In 1903 it appeared in the form of a "Code of Ethics and Deontology" and was prepared by the Board of the Medical Register of Sassari (Sardinia). This Board inserted the principles inspiring the correct practice of the medical profession in an articulated and self-normative system, also foreseeing disciplinary measures. About ten years later, in 1912, the Medical Register of Turin (Piedmont) elaborated a Code which constituted the basis for a subsequent elaboration leading to a Unified Code of Medical Ethics (1924). After World War II the idea prevailed in Italy that the codes of medical deontology should undergo periodical review, updating and dissemination, and the new 1947 text (Turin) was for the first time amply diffused among Italian physicians. The next national code dates back to 1958, and twenty years later a revision was published. In the 1989 Code new topics appeared, including organ transplantation, artificial in vitro insemination and the role of police doctors; these and other issues were later developed in the 1995, 1998 and 2006 versions of the Code. The last available edition of the Italian Code of Medical Deontology is that of May 2014.
Evaluation of a bar-code system to detect unaccompanied baggage
DOT National Transportation Integrated Search
1988-02-01
The objective of the Unaccompanied Baggage Detection System (UBDS) Project has : been to gain field experience with a system designed to identify passengers who : check baggage for a flight and subsequently fail to board that flight. In the first : p...
The 21st Century School Business Office.
ERIC Educational Resources Information Center
Ecker, Marc; McMahon, Stephen; Minnesang, Patricia
2000-01-01
Technological advancements are helping school business officials at the Fountain Valley (California) School District effectively manage district assets, thanks to developments in budget and finance software, videoconferencing, online purchasing and fund raising, inventory bar codes and portable scanners, paperless forms and applications, writable…
Ching, Joan M; Williams, Barbara L; Idemoto, Lori M; Blackmore, C Craig
2014-08-01
Virginia Mason Medical Center (Seattle) employed the Lean concept of Jidoka (automation with a human touch) to plan for and deploy bar code medication administration (BCMA) to hospitalized patients. Integrating BCMA technology into the nursing work flow with minimal disruption was accomplished using three steps ofJidoka: (1) assigning work to humans and machines on the basis of their differing abilities, (2) adapting machines to the human work flow, and (3) monitoring the human-machine interaction. Effectiveness of BCMA to both reinforce safe administration practices and reduce medication errors was measured using the Collaborative Alliance for Nursing Outcomes (CALNOC) Medication Administration Accuracy Quality Study methodology. Trained nurses observed a total of 16,149 medication doses for 3,617 patients in a three-year period. Following BCMA implementation, the number of safe practice violations decreased from 54.8 violations/100 doses (January 2010-September 2011) to 29.0 violations/100 doses (October 2011-December 2012), resulting in an absolute risk reduction of 25.8 violations/100 doses (95% confidence interval [CI]: 23.7, 27.9, p < .001). The number of medication errors decreased from 5.9 errors/100 doses at baseline to 3.0 errors/100 doses after BCMA implementation (absolute risk reduction: 2.9 errors/100 doses [95% CI: 2.2, 3.6,p < .001]). The number of unsafe administration practices (estimate, -5.481; standard error 1.133; p < .001; 95% CI: -7.702, -3.260) also decreased. As more hospitals respond to health information technology meaningful use incentives, thoughtful, methodical, and well-managed approaches to technology deployment are crucial. This work illustrates how Jidoka offers opportunities for a smooth transition to new technology.
The application of coded excitation technology in medical ultrasonic Doppler imaging
NASA Astrophysics Data System (ADS)
Li, Weifeng; Chen, Xiaodong; Bao, Jing; Yu, Daoyin
2008-03-01
Medical ultrasonic Doppler imaging is one of the most important domains of modern medical imaging technology. The application of coded excitation technology in medical ultrasonic Doppler imaging system has the potential of higher SNR and deeper penetration depth than conventional pulse-echo imaging system, it also improves the image quality, and enhances the sensitivity of feeble signal, furthermore, proper coded excitation is beneficial to received spectrum of Doppler signal. Firstly, this paper analyzes the application of coded excitation technology in medical ultrasonic Doppler imaging system abstractly, showing the advantage and bright future of coded excitation technology, then introduces the principle and the theory of coded excitation. Secondly, we compare some coded serials (including Chirp and fake Chirp signal, Barker codes, Golay's complementary serial, M-sequence, etc). Considering Mainlobe Width, Range Sidelobe Level, Signal-to-Noise Ratio and sensitivity of Doppler signal, we choose Barker codes as coded serial. At last, we design the coded excitation circuit. The result in B-mode imaging and Doppler flow measurement coincided with our expectation, which incarnated the advantage of application of coded excitation technology in Digital Medical Ultrasonic Doppler Endoscope Imaging System.
On the Offset of Barred Galaxies from the Black Hole M BH-σ Relationship
NASA Astrophysics Data System (ADS)
Brown, Jonathan S.; Valluri, Monica; Shen, Juntai; Debattista, Victor P.
2013-12-01
We use collisionless N-body simulations to determine how the growth of a supermassive black hole (SMBH) influences the nuclear kinematics in both barred and unbarred galaxies. In the presence of a bar, the increase in the velocity dispersion σ (within the effective radius) due to the growth of an SMBH is on average <~ 10%, whereas the increase is only <~ 4% in an unbarred galaxy. In a barred galaxy, the increase results from a combination of three separate factors: (1) orientation and inclination effects; (2) angular momentum transport by the bar that results in an increase in the central mass density; and (3) an increase in the vertical and radial velocity anisotropy of stars in the vicinity of the SMBH. In contrast, the growth of the SMBH in an unbarred galaxy causes the velocity distribution in the inner part of the nucleus to become less radially anisotropic. The increase in σ following the growth of the SMBH is insensitive to a variation of a factor of 10 in the final mass of the SMBH, showing that it is the growth process rather than the actual SMBH mass that alters bar evolution in a way that increases σ. We argue that using an axisymmetric stellar dynamical modeling code to measure SMBH masses in barred galaxies could result in a slight overestimate of the derived M BH, especially if a constant M/L ratio is assumed. We conclude that the growth of a black hole in the presence of a bar could result in an increase in σ that is roughly 4%-8% larger than the increase that occurs in an axisymmetric system. While the increase in σ due to SMBH growth in a barred galaxy might partially account for the claimed offset of barred galaxies and pseudo bulges from the M BH-σ relation obtained for elliptical galaxies and classical bulges in unbarred galaxies, it is inadequate to account for all of the offset.
45 CFR 162.1002 - Medical data code sets.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Terminology, Fourth Edition (CPT-4), as maintained and distributed by the American Medical Association, for... 45 Public Welfare 1 2012-10-01 2012-10-01 false Medical data code sets. 162.1002 Section 162.1002... REQUIREMENTS ADMINISTRATIVE REQUIREMENTS Code Sets § 162.1002 Medical data code sets. The Secretary adopts the...
45 CFR 162.1002 - Medical data code sets.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Terminology, Fourth Edition (CPT-4), as maintained and distributed by the American Medical Association, for... 45 Public Welfare 1 2014-10-01 2014-10-01 false Medical data code sets. 162.1002 Section 162.1002... REQUIREMENTS ADMINISTRATIVE REQUIREMENTS Code Sets § 162.1002 Medical data code sets. The Secretary adopts the...
45 CFR 162.1002 - Medical data code sets.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Terminology, Fourth Edition (CPT-4), as maintained and distributed by the American Medical Association, for... 45 Public Welfare 1 2013-10-01 2013-10-01 false Medical data code sets. 162.1002 Section 162.1002... REQUIREMENTS ADMINISTRATIVE REQUIREMENTS Code Sets § 162.1002 Medical data code sets. The Secretary adopts the...
45 CFR 162.1002 - Medical data code sets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Terminology, Fourth Edition (CPT-4), as maintained and distributed by the American Medical Association, for... 45 Public Welfare 1 2011-10-01 2011-10-01 false Medical data code sets. 162.1002 Section 162.1002... REQUIREMENTS ADMINISTRATIVE REQUIREMENTS Code Sets § 162.1002 Medical data code sets. The Secretary adopts the...
45 CFR 162.1002 - Medical data code sets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Terminology, Fourth Edition (CPT-4), as maintained and distributed by the American Medical Association, for... 45 Public Welfare 1 2010-10-01 2010-10-01 false Medical data code sets. 162.1002 Section 162.1002... REQUIREMENTS ADMINISTRATIVE REQUIREMENTS Code Sets § 162.1002 Medical data code sets. The Secretary adopts the...
16 CFR 309.21 - Labeling requirements for used covered vehicles.
Code of Federal Regulations, 2012 CFR
2012-01-01
... numbers, bar codes, and vehicle identification numbers consistent with Figure 6. (c) Type size and setting... vehicles. 309.21 Section 309.21 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS LABELING REQUIREMENTS FOR ALTERNATIVE FUELS AND ALTERNATIVE FUELED VEHICLES...
16 CFR 309.21 - Labeling requirements for used covered vehicles.
Code of Federal Regulations, 2013 CFR
2013-01-01
... numbers, bar codes, and vehicle identification numbers consistent with Figure 6. (c) Type size and setting... vehicles. 309.21 Section 309.21 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS LABELING REQUIREMENTS FOR ALTERNATIVE FUELS AND ALTERNATIVE FUELED VEHICLES...
16 CFR 309.20 - Labeling requirements for new covered vehicles.
Code of Federal Regulations, 2013 CFR
2013-01-01
... numbers, bar codes, and vehicle identification numbers consistent with Figures 4, 5, and 5.1. (c) Type... vehicles. 309.20 Section 309.20 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS LABELING REQUIREMENTS FOR ALTERNATIVE FUELS AND ALTERNATIVE FUELED VEHICLES...
16 CFR 309.20 - Labeling requirements for new covered vehicles.
Code of Federal Regulations, 2012 CFR
2012-01-01
... numbers, bar codes, and vehicle identification numbers consistent with Figures 4, 5, and 5.1. (c) Type... vehicles. 309.20 Section 309.20 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS LABELING REQUIREMENTS FOR ALTERNATIVE FUELS AND ALTERNATIVE FUELED VEHICLES...
48 CFR 252.211-7003 - Item identification and valuation.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., used to retrieve data encoded on machine-readable media. Concatenated unique item identifier means— (1... (or controlling) authority for the enterprise identifier. Item means a single hardware article or a...-readable means an automatic identification technology media, such as bar codes, contact memory buttons...
48 CFR 252.211-7003 - Item identification and valuation.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., used to retrieve data encoded on machine-readable media. Concatenated unique item identifier means— (1... (or controlling) authority for the enterprise identifier. Item means a single hardware article or a...-readable means an automatic identification technology media, such as bar codes, contact memory buttons...
48 CFR 252.211-7003 - Item identification and valuation.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., used to retrieve data encoded on machine-readable media. Concatenated unique item identifier means— (1... (or controlling) authority for the enterprise identifier. Item means a single hardware article or a...-readable means an automatic identification technology media, such as bar codes, contact memory buttons...
75 FR 10414 - Researcher Identification Card
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-08
... capturing administrative information on the characteristics of our users. Other forms of identification are... use bar-codes on researcher identification cards in the Washington, DC, area. The plastic cards we... plastic researcher identification cards as part of their security systems, we issue a plastic card to...
Automatic Ammunition Identification Technology Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weil, B.
1993-01-01
The Automatic Ammunition Identification Technology (AAIT) Project is an activity of the Robotics Process Systems Division at the Oak Ridge National Laboratory (ORNL) for the US Army's Project Manager-Ammunition Logistics (PM-AMMOLOG) at the Picatinny Arsenal in Picatinny, New Jersey. The project objective is to evaluate new two-dimensional bar code symbologies for potential use in ammunition logistics systems and automated reloading equipment. These new symbologies are a significant improvement over typical linear bar codes since machine-readable alphanumeric messages up to 2000 characters long are achievable. These compressed data symbologies are expected to significantly improve logistics and inventory management tasks and permitmore » automated feeding and handling of ammunition to weapon systems. The results will be increased throughout capability, better inventory control, reduction of human error, lower operation and support costs, and a more timely re-supply of various weapon systems. This paper will describe the capabilities of existing compressed data symbologies and the symbol testing activities being conducted at ORNL for the AAIT Project.« less
Automatic Ammunition Identification Technology Project. Ammunition Logistics Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weil, B.
1993-03-01
The Automatic Ammunition Identification Technology (AAIT) Project is an activity of the Robotics & Process Systems Division at the Oak Ridge National Laboratory (ORNL) for the US Army`s Project Manager-Ammunition Logistics (PM-AMMOLOG) at the Picatinny Arsenal in Picatinny, New Jersey. The project objective is to evaluate new two-dimensional bar code symbologies for potential use in ammunition logistics systems and automated reloading equipment. These new symbologies are a significant improvement over typical linear bar codes since machine-readable alphanumeric messages up to 2000 characters long are achievable. These compressed data symbologies are expected to significantly improve logistics and inventory management tasks andmore » permit automated feeding and handling of ammunition to weapon systems. The results will be increased throughout capability, better inventory control, reduction of human error, lower operation and support costs, and a more timely re-supply of various weapon systems. This paper will describe the capabilities of existing compressed data symbologies and the symbol testing activities being conducted at ORNL for the AAIT Project.« less
Potential Explosion Hazard of Carbonaceous Nanoparticles: Screening of Allotropes
Turkevich, Leonid A.; Fernback, Joseph; Dastidar, Ashok G.; Osterberg, Paul
2016-01-01
There is a concern that engineered carbon nanoparticles, when manufactured on an industrial scale, will pose an explosion hazard. Explosion testing has been performed on 20 codes of carbonaceous powders. These include several different codes of SWCNTs (single-walled carbon nanotubes), MWCNTs (multi-walled carbon nanotubes) and CNFs (carbon nanofibers), graphene, diamond, fullerene, as well as several different control carbon blacks and graphites. Explosion screening was performed in a 20 L explosion chamber (ASTM E1226 protocol), at a concentration of 500 g/m3, using a 5 kJ ignition source. Time traces of overpressure were recorded. Samples typically exhibited overpressures of 5–7 bar, and deflagration index KSt = V1/3 (dP/dt)max ~ 10 – 80 bar-m/s, which places these materials in European Dust Explosion Class St-1. There is minimal variation between these different materials. The explosive characteristics of these carbonaceous powders are uncorrelated with primary particle size (BET specific surface area). PMID:27468178
Codes of professional responsibility for lawyers: ethics or law?
Lawry, R P
1984-01-01
The American Bar Association has three times in this century produced a code of ethics for lawyers. The movement has clearly been from a general, hortatory format to one of a statement of principles of law. In the ABA's latest effort, the problems of client confidentiality loom as the most serious and most difficult to solve. The question of ethics versus law weighs heavily in this context, and the ABA's latest resolutions of the confidentiality problems are found to be unsatisfactory.
2002-09-01
employed by the supermarket industry in 1973. Other common linear bar code symbologies are Code 39, pioneered by the defense and automotive industries...Teller Machine ( ATM ) cards are one of the prominent uses of this technology, but to a lesser extent, the technology has been used for shop floor...additional power is transmitted to it through the probe, extending its charge. There is a risk of data loss if the CMB is not accessed from time to time
Environmental Mapping by a HERO-1 Robot Using Sonar and a Laser Barcode Scanner.
1983-12-01
can be labled with an x-y type coordinate grid allowing the rover to directly read * its location as it moves along. A different approach is to...uses a two-dimensional grid of two character barcodes as reference objects. Since bar codes are designed to be read in either of two orientations (top...Processing Laboratory at AFIT (see Appendix B for listing). Navigation grid codes consist of two digits running consecutively from 00 to FF, yielding 256
An Epidemic of Oroya Fever in the Peruvian Andes
1990-01-01
otras Enfermedads MAmisiero de Salud. Lima. Peru. Naval Medical Research Instaitue. Bethesda. Af: Naval Medical Research Institsaae Derachmeint. Dma. Peru...review of the manuscript. tibastonella en la enfermedad de carrion o bar- trhe outstanding field work of Enrique Morales. Jaime tonelosis humana
Measurement and simulation of deformation and stresses in steel casting
NASA Astrophysics Data System (ADS)
Galles, D.; Monroe, C. A.; Beckermann, C.
2012-07-01
Experiments are conducted to measure displacements and forces during casting of a steel bar in a sand mold. In some experiments the bar is allowed to contract freely, while in others the bar is manually strained using embedded rods connected to a frame. Solidification and cooling of the experimental castings are simulated using a commercial code, and good agreement between measured and predicted temperatures is obtained. The deformations and stresses in the experiments are simulated using an elasto-viscoplastic finite-element model. The high temperature mechanical properties are estimated from data available in the literature. The mush is modeled using porous metal plasticity theory, where the coherency and coalescence solid fraction are taken into account. Good agreement is obtained between measured and predicted displacements and forces. The results shed considerable light on the modeling of stresses in steel casting and help in developing more accurate models for predicting hot tears and casting distortions.
Orbital tori for non-axisymmetric galaxies
NASA Astrophysics Data System (ADS)
Binney, James
2018-02-01
Our Galaxy's bar makes the Galaxy's potential distinctly non-axisymmetric. All orbits are affected by non-axisymmetry, and significant numbers are qualitatively changed by being trapped at a resonance with the bar. Orbital tori are used to compute these effects. Thick-disc orbits are no less likely to be trapped by corotation or a Lindblad resonance than thin-disc orbits. Perturbation theory is used to create non-axisymmetric orbital tori from standard axisymmetric tori, and both trapped and untrapped orbits are recovered to surprising accuracy. Code is added to the TorusModeller library that makes it as easy to manipulate non-axisymmetric tori as axisymmetric ones. The augmented TorusModeller is used to compute the velocity structure of the solar neighbourhood for bars of different pattern speeds and a simple action-based distribution function. The technique developed here can be applied to any non-axisymmetric potential that is stationary in a rotating from - hence also to classical spiral structure.
ERIC Educational Resources Information Center
King, Angela G.
2004-01-01
Nanotechnology are employed by researchers at Northwestern University to develop a method of labeling disease markers present in blood with unique DNA tags they have dubbed "bio-bar-codes". The preparation of nanoparticle and magnetic microparticle probes and a nanoparticle-based PSR-less DNA amplification scheme are involved by the DNA-BCA assay.
NASA Astrophysics Data System (ADS)
King, Angela G.
2004-10-01
This Report from Other Journals surveys articles of interest to chemists that have been recently published in other science journals. The articles selected specifically relate to the theme of National Chemistry Week 2004: health and wellness.
ERIC Educational Resources Information Center
Cowan, Les
1990-01-01
Outlines and analyzes new trends and developments at the Association for Information and Image Management's 1990 spring conference. The growth of imaging and the optical storage industry is emphasized, and new developments that are discussed include hardware; optical disk drives; jukeboxes; local area networks (LANs); bar codes; image displays;…
National Centers for Environmental Prediction
Organization Search Enter text Search Navigation Bar End Cap Search EMC Go Branches Global Climate and Weather Modeling Mesoscale Modeling Marine Modeling and Analysis Teams Climate Data Assimilation Ensembles and Post Model Configuration Collaborators Documentation and Code FAQ Operational Change Log Parallel Experiment
Jovian Chromophore Characteristics from Multispectral HST Images
NASA Technical Reports Server (NTRS)
Strycker, Paul D.; Chanover, Nancy J.; Simon-Miller, Amy A.; Banfield, Don; Gierasch, Peter J.
2011-01-01
The chromophores responsible for coloring the jovian atmosphere are embedded within Jupiter's vertical aerosol structure. Sunlight propagates through this vertical distribution of aerosol particles, whose colors are defined by omega-bar (sub 0)(lambda), and we remotely observe the culmination of the radiative transfer as I/F(lambda). In this study, we employed a radiative transfer code to retrieve omega-bar (sub 0)(lambda) for particles in Jupiter's tropospheric haze at seven wavelengths in the near-UV and visible regimes. The data consisted of images of the 2008 passage of Oval BA to the south of the Great Red Spot obtained by the Wide Field Planetary Camera 2 on-board the Hubble Space Telescope. We present derived particle colors for locations that were selected from 14 weather regions, which spanned a large range of observed colors. All omega-bar (sub 0)(lambda) curves were absorbing in the blue, and omega-bar (sub 0)(lambda) increased monotonically to approximately unity as wavelength increased. We found accurate fits to all omega-bar (sub 0)(lambda) curves using an empirically derived functional form: omega-bar (sub 0)(lambda) = 1 A exp(-B lambda). The best-fit parameters for the mean omega-bar (sub 0)(lambda) curve were A = 25.4 and B = 0.0149 for lambda in units of nm. We performed a principal component analysis (PCA) on our omega-bar (sub 0)(lambda) results and found that one or two independent chromophores were sufficient to produce the variations in omega-bar (sub 0)(lambda). A PCA of I/F(lambda) for the same jovian locations resulted in principal components (PCs) with roughly the same variances as the omega-bar (sub 0)(lambda) PCA, but they did not result in a one-to-one mapping of PC amplitudes between the omega-bar (sub 0)(lambda) PCA and I/F(lambda) PCA. We suggest that statistical analyses performed on I/ F(lambda) image cubes have limited applicability to the characterization of chromophores in the jovian atmosphere due to the sensitivity of 1/ F(lambda) to horizontal variations in the vertical aerosol distribution.
An interactive histology image-barcode manual for a videodisc image library.
Ogilvie, R W
1995-01-01
Cell Biology and HISTOLOGY (alias Microanatomy, alias Microscopic Anatomy) is a required course for first-year medical and dental students in most health science centers. The traditional approach used in teaching this discipline is to present photomicrographic images of structures to students in lecture using 35 mm slides of fields seen through the microscope. The students then spend many hours viewing and studying specimens of tissues using a light microscope in a laboratory setting. Students in traditional courses of histology spend an inordinate amount of time learning the component structures by attempting to find and identify them in tissue sections using a microscope, where the structure being sought is surrounded by a multitude of other structures with which they are also not familiar. With the recent availability of videodisc stored image libraries of histological samples, it is now possible to study histological principles without the use of the microscope as the primary learning tool. A videodisc entitled " A Photographic Atlas" by S. Downing (published by Image Premastering Services Limited, Minneapolis, MN, 1991) has been incorporated into our histology course. Fifteen videodisc player stations are provided for 150 students. Images are retrieved by students using a bar code scanner attached to a videodisc player (Pioneer CLD-2400). Using this kind of image library, students can now learn basic histological structure, such as cell and tissue types, without the use of a microscope or as a tool for facilitating microscopy. The use of a videodisc library of randomly accessible images simplifies learning the basic components which all organs are composed of by presenting the learner with clear-cut examples to avoid confusion with other structures. However, videodisc players and TV monitors are still not appropriately priced for every student to own. This presents a problem in that the same images studied in class are not available to study and review outside of class. There is a need for resources for additional study outside of the institutional setting, for students to have and interact with to reinforce the learning experience in the teaching laboratory. A hard copy manual was created and is being used in our course; it incorporates photos captured from the videodisc. The images displayed in the manual are chosen to give the student one example of each histological component. Additional labeling is added to the images, and each image is accompanied by a bar code that may be used at a videodisc player with a bar code reader to retrieve the same color image from the disc displayed in larger format on a TV monitor. Each topic in the manual is accompanied by learning objectives and a statement of clinical relevance. Following the presentation of the images in each section of the manual, the students are encouraged to practice by viewing multiple examples of each structural component presented in the lesson. They can do this by using the bar-coded catalog supplied with each disc. The presentation of each topic concludes with a quiz composed of questions about images that the student can retrieve from the videodisc using barcodes in the text of the manual. Some of the images on the quiz are printed in miniature in the manual to provide the student with an opportunity for personal review at home when hardware to obtain and display images from a video disc is not available. This manual provides an answer to the dilemma faced by the learner when access to hardware is not available; reinforcement is therefore facilitated outside the teaching laboratory. This allows learning to continue outside of the classroom, using the same materials. (abstract truncated)
Improved Software to Browse the Serial Medical Images for Learning.
Kwon, Koojoo; Chung, Min Suk; Park, Jin Seo; Shin, Byeong Seok; Chung, Beom Sun
2017-07-01
The thousands of serial images used for medical pedagogy cannot be included in a printed book; they also cannot be efficiently handled by ordinary image viewer software. The purpose of this study was to provide browsing software to grasp serial medical images efficiently. The primary function of the newly programmed software was to select images using 3 types of interfaces: buttons or a horizontal scroll bar, a vertical scroll bar, and a checkbox. The secondary function was to show the names of the structures that had been outlined on the images. To confirm the functions of the software, 3 different types of image data of cadavers (sectioned and outlined images, volume models of the stomach, and photos of the dissected knees) were inputted. The browsing software was downloadable for free from the homepage (anatomy.co.kr) and available off-line. The data sets provided could be replaced by any developers for their educational achievements. We anticipate that the software will contribute to medical education by allowing users to browse a variety of images. © 2017 The Korean Academy of Medical Sciences.
[Comparative review of the Senegalese and French deontology codes].
Soumah, M; Mbaye, I; Bah, H; Gaye Fall, M C; Sow, M L
2005-01-01
The medical deontology regroups duties of the physicians and regulate the exercise of medicine. The code of medical deontology of Senegal inspired of the French medical deontology code, has not been revised since its institution whereas the French deontology code knew three revisions. Comparing the two codes of deontology titles by title and article by article, this work beyond a parallel between the two codes puts in inscription the progress in bioethics that are to the basis of the revisions of the French medical deontology code. This article will permit an advocacy of the health professionals, in favor of a setting to level of the of Senegalese medical deontology code. Because legal litigation, that is important in the developed countries, intensify in our developing countries. It is inherent to the technological progress and to the awareness of the patients of their rights.
ERIC Educational Resources Information Center
Roberts, Larry
2011-01-01
The word laser is an acronym. It stands for Light Amplification by Stimulated Emission of Radiation. Lasers, invented in 1958, are used to cut and fuse materials, accurately survey long distances, communicate across fiber-optic phone lines, produce 3D pictures, make special effects, help navigation, and read bar codes for cash registers. A laser…
The Fine Art of Using a Laserdisc in the Art Classroom.
ERIC Educational Resources Information Center
Porter, Sharon
1998-01-01
Laserdiscs are an efficient and flexible medium for art presentations in schools. This article discusses laserdiscs, also called videodiscs; distinguishes between constant linear velocity (CLV) and constant angular velocity (CAV) which allows more flexible access; describes the use of bar coding for access; and lists selected visual art…
National Centers for Environmental Prediction
Organization Search Enter text Search Navigation Bar End Cap Search EMC Go Branches Global Climate and Weather Modeling Mesoscale Modeling Marine Modeling and Analysis Teams Climate Data Assimilation Ensembles and Post Configuration Collaborators Documentation and Code FAQ Operational Change Log Parallel Experiment Change Log
National Centers for Environmental Prediction
Organization Search Enter text Search Navigation Bar End Cap Search EMC Go Branches Global Climate and Weather Modeling Mesoscale Modeling Marine Modeling and Analysis Teams Climate Data Assimilation Ensembles and Post Collaborators Documentation and Code FAQ Operational Change Log Parallel Experiment Change Log Contacts
Twenty-Second Annual NASA Supply and Equipment Management Conference
NASA Technical Reports Server (NTRS)
1989-01-01
The status of actions from the 1988 conference is reviewed. Environmental safety issues, definitions, and regulations; contract transition, payload logistics transition, and safety and support equipment; supply products and services, bar code technology, and inventory accuracy; equipment management workshop topics; and contract property workshop topics are outlined.
QR code for medical information uses.
Fontelo, Paul; Liu, Fang; Ducut, Erick G
2008-11-06
We developed QR code online tools, simulated and tested QR code applications for medical information uses including scanning QR code labels, URLs and authentication. Our results show possible applications for QR code in medicine.
Lobaugh, Lauren M Y; Martin, Lizabeth D; Schleelein, Laura E; Tyler, Donald C; Litman, Ronald S
2017-09-01
Wake Up Safe is a quality improvement initiative of the Society for Pediatric Anesthesia that contains a deidentified registry of serious adverse events occurring in pediatric anesthesia. The aim of this study was to describe and characterize reported medication errors to find common patterns amenable to preventative strategies. In September 2016, we analyzed approximately 6 years' worth of medication error events reported to Wake Up Safe. Medication errors were classified by: (1) medication category; (2) error type by phase of administration: prescribing, preparation, or administration; (3) bolus or infusion error; (4) provider type and level of training; (5) harm as defined by the National Coordinating Council for Medication Error Reporting and Prevention; and (6) perceived preventability. From 2010 to the time of our data analysis in September 2016, 32 institutions had joined and submitted data on 2087 adverse events during 2,316,635 anesthetics. These reports contained details of 276 medication errors, which comprised the third highest category of events behind cardiac and respiratory related events. Medication errors most commonly involved opioids and sedative/hypnotics. When categorized by phase of handling, 30 events occurred during preparation, 67 during prescribing, and 179 during administration. The most common error type was accidental administration of the wrong dose (N = 84), followed by syringe swap (accidental administration of the wrong syringe, N = 49). Fifty-seven (21%) reported medication errors involved medications prepared as infusions as opposed to 1 time bolus administrations. Medication errors were committed by all types of anesthesia providers, most commonly by attendings. Over 80% of reported medication errors reached the patient and more than half of these events caused patient harm. Fifteen events (5%) required a life sustaining intervention. Nearly all cases (97%) were judged to be either likely or certainly preventable. Our findings characterize the most common types of medication errors in pediatric anesthesia practice and provide guidance on future preventative strategies. Many of these errors will be almost entirely preventable with the use of prefilled medication syringes to avoid accidental ampule swap, bar-coding at the point of medication administration to prevent syringe swap and to confirm the proper dose, and 2-person checking of medication infusions for accuracy.
Stanbury, Martha; Chester, Debra; Hanna, Elizabeth A; Rosenman, Kenneth D
2008-02-01
Despite epidemiologic, experimental and observational data on the association of environmental tobacco smoke (ETS) and adverse health effects, bar and restaurant workers remain exposed to ETS in the majority of states and countries. Three public health surveillance systems were used to identify and conduct a follow-up investigation of a reported acute asthma death of a young waitress in a bar. The waitress collapsed at the bar where she worked and was declared dead shortly thereafter. Evaluation of the circumstances of her death and her medical history concluded that her death was from acute asthma due to environmental tobacco smoke at work. This is the first reported acute asthma death associated with work-related ETS. Recent studies of asthma among bar and restaurant workers before and after smoking bans support this association. This death dramatizes the need to enact legal protections for workers in the hospitality industry from secondhand smoke.
Report on FY15 Two-Bar Thermal Ratcheting Test Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yanli; Jetter, Robert I; Baird, Seth T
2015-06-22
Alloy 617 is a reference structural material for very high temperature components of advanced-gas cooled reactors with outlet temperatures in the range of . In order for designers to be able to use Alloy 617 for these high temperature components, Alloy 617 has to be approved for use in Section III (the nuclear section) of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. A plan has been developed to submit a draft code for Alloy 617 to ASME Section III by 2015. However, the current rules in Subsection NH* for the evaluation of strain limits andmore » creep-fatigue damage using simplified methods based on elastic analysis have been deemed inappropriate for Alloy 617 at temperatures above . The rationale for this exclusion is that at higher temperatures it is not feasible to decouple plasticity and creep deformation, which is the basis for the current simplified rules. This temperature, , is well below the temperature range of interest for this material in High Temperature Gas Cooled Reactor (HTGR) applications. The only current alternative is, thus, a full inelastic analysis which requires sophisticated material models which have been formulated but not yet verified. To address this issue, proposed code rules have been developed which are based on the use of elastic-perfectly plastic (EPP) analysis methods and which are expected to be applicable to very high temperatures. These newly proposed rules also address a long-term objective to provide an option for more simple, comprehensive and easily applied rules than the current so called simplified rules These two-bar tests discussed herein are part of an ongoing series of tests with cyclic loading at high temperatures using specimens representing key features of potential component designs. The initial focus of the two-bar ratcheting test program, to verify the procedure for evaluation of strain limits for Alloy 617 at very high temperatures, has been expanded to respond to guidance from ASME Code committees that the proposed EPP methodology should also apply to other Subsection NH materials throughout their allowed temperature range. To support these objectives, two suites of tests have been accomplished during this reporting period. One suite addresses the issue of the response of Alloy 617 at a lower temperature with tests in range of 500 800oC and a few at 350 650°C. The other suite addresses the response of SS316H up to its current maximum allowed temperature of 1500°F (815°C) In the two-bar test methodology, the two bars can be viewed as specimens taken out of a tubular component across the wall thickness representing the inner wall element and the outer wall element respectively. The two bars are alternately heated and cooled under sustained axial loading to generate ratcheting. A sustained hold time is introduced at the hot extreme of the cycle to capture the accelerated ratcheting and strain accumulation due to creep. Since the boundary conditions are a combination of strain control and load control it is necessary to use two coupled servo-controlled testing machines to achieve the key features of the two-bar representation of actual component behavior. Two-bar thermal ratcheting test results with combinations of applied mean stresses, transient temperature difference and heating and cooling rates were recorded. Tests performed at heating and cooling rates of 30°C/min are comparable to a strain rate of 10 ⁻⁵/sec. At high mean stresses in tension the direction of ratcheting was in-phase with the load, e.g. tensile strain ratcheting under high tensile loading; however, at lower loads, strain ratcheting in compression was observed under net tensile mean stresses. The strain accumulation was proportional to the applied thermal load. However, there was a narrow range of applied load in which the high applied thermal loading did not result in significant strain accumulation. Unfortunately, when the proposed EPP strain limit evaluation rules were applied to the loading history for the two-bar configuration, the predicted narrow range of low strain accumulation did not coincide with the experimental data. However, by the use of inelastic analysis in conjunction with an analytic experiment it was possible to show that the EPP strain limit code case rules could be applied to high temperature structures where the stress and temperature is not uniform throughout which is the general case. Interestingly, the suite of tests on Alloy 617 at the lower temperature range of 500°C to 800oC showed good agreement with the proposed EPP strain limit rules with a much wider band of applied load that exhibited minimal ratcheting. The four tests conducted at the lower temperature range of 350°C to 650°C showed no ratcheting. The suite of tests on SS316H at a temperature range of 515°C to 815°C resembled the results from the tests on Alloy 617 at 650°C to 950°C. Both exhibited a narrow band of applied load wher...« less
What determines successful implementation of inpatient information technology systems?
Spetz, Joanne; Burgess, James F; Phibbs, Ciaran S
2012-03-01
To identify the factors and strategies that were associated with successful implementation of hospital-based information technology (IT) systems in US Department of Veterans Affairs (VA) hospitals, and how these might apply to other hospitals. Qualitative analysis of 118 interviews conducted at 7 VA hospitals. The study focused on the inpatient setting, where nurses are the main patient-care providers; thus, the research emphasized the impact of Computerized Patient Record System and Bar Code Medication Administration on nurses. Hospitals were selected to represent a range of IT implementation dates, facility sizes, and geography. The subjects included nurses, pharmacists, physicians, IT staff, and managers. Interviews were guided by a semi-structured interview protocol, and a thematic analysis was conducted, with initial codes drawn from the content of the interview guides. Additional themes were proposed as the coding was conducted. Five broad themes arose as factors which affected the process and success of implementation: (1) organizational stability and implementation team leadership, (2) implementation timelines, (3) equipment availability and reliability, (4) staff training, and (5) changes in work flow Overall IT implementation success in the VA depended on: (1) whether there was support for change from both leaders and staff, (2) development of a gradual and flexible implementation approach, (3) allocation of adequate resources for equipment and infrastructure, hands-on support, and deployment of additional staff, and (4) how the implementation team planned for setbacks, and continued the process to achieve success. Problems that developed in the early stages of implementation tended to become persistent, and poor implementation can lead to patient harm.
Evaluation and implementation of QR Code Identity Tag system for Healthcare in Turkey.
Uzun, Vassilya; Bilgin, Sami
2016-01-01
For this study, we designed a QR Code Identity Tag system to integrate into the Turkish healthcare system. This system provides QR code-based medical identification alerts and an in-hospital patient identification system. Every member of the medical system is assigned a unique QR Code Tag; to facilitate medical identification alerts, the QR Code Identity Tag can be worn as a bracelet or necklace or carried as an ID card. Patients must always possess the QR Code Identity bracelets within hospital grounds. These QR code bracelets link to the QR Code Identity website, where detailed information is stored; a smartphone or standalone QR code scanner can be used to scan the code. The design of this system allows authorized personnel (e.g., paramedics, firefighters, or police) to access more detailed patient information than the average smartphone user: emergency service professionals are authorized to access patient medical histories to improve the accuracy of medical treatment. In Istanbul, we tested the self-designed system with 174 participants. To analyze the QR Code Identity Tag system's usability, the participants completed the System Usability Scale questionnaire after using the system.
An Analysis of the Changes in Communication Techniques in the Italian Codes of Medical Deontology.
Conti, Andrea Alberto
2017-04-28
The code of deontology of the Italian National Federation of the Colleges of Physicians, Surgeons and Dentists (FNOMCeO) contains the principles and rules to which the professional medical practitioner must adhere. This work identifies and analyzes the medical-linguistic choices and the expressive techniques present in the different editions of the code, and evaluates their purpose and function, focusing on the first appearance and the subsequent frequency of key terms. Various aspects of the formal and expressive revisions of the eight editions of the Codes of Medical Deontology published after the Second World War (from 1947/48 to 2014) are here presented, starting from a brief comparison with the first edition of 1903. Formal characteristics, choices of medical terminology and the introduction of new concepts and communicative attitudes are here identified and evaluated. This paper, in presenting a quantitative and epistemological analysis of variations, modifications and confirmations in the different editions of the Italian code of medical deontology over the last century, enucleates and demonstrates the dynamic paradigm of changing attitudes in the medical profession. This analysis shows the evolution in medical-scientific communication as embodied in the Italian code of medical deontology. This code, in its adoption, changes and adaptations, as evidenced in its successive editions, bears witness to the expressions and attitudes pertinent to and characteristic of the deontological stance of the medical profession during the twentieth century.
Computerized Systems for Collecting Real-Time Observational Data.
ERIC Educational Resources Information Center
Kahng, SungWoo; Iwata, Brian
1998-01-01
A survey of 15 developers of computerized real-time observation systems found many systems have incorporated laptop or handheld computers as well as bar-code scanners. Most systems used IBM-compatible software, and ranged from free to complete systems costing more than $1,500. Data analysis programs were included with most programs. (Author/CR)
76 FR 12847 - Change of Address; Requests for Exemption From the Bar Code Label Requirements
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-09
... INFORMATION CONTACT: Rikin Mehta, Center for Drug Evaluation and Research, Food and Drug Administration, 10903... and Research, Food and Drug Administration, 10903 New Hampshire Ave., Bldg. 51, Silver Spring, MD... Evaluation and Research, Food and Drug Administration, 10903 New Hampshire Ave., Bldg. 51, Silver Spring, MD...
Redesigning the Human-Machine Interface for Computer-Mediated Visual Technologies.
ERIC Educational Resources Information Center
Acker, Stephen R.
1986-01-01
This study examined an application of a human machine interface which relies on the use of optical bar codes incorporated in a computer-based module to teach radio production. The sequencing procedure used establishes the user rather than the computer as the locus of control for the mediated instruction. (Author/MBR)
Wassef, H. H.; Fox, E.; Abbatte, E. A.; Tolédo, J. F.; Rodier, G.
1989-01-01
Sexually transmitted diseases (STDs) are an increasing public health problem in Djibouti. The authors have attempted to obtain basic information on the level of knowledge concerning STDs and on the sexual behaviour of highly sexually promiscuous individuals for use in the organization of future STD control programmes; the information was obtained from a population of 213 bar hostesses, 66 unlicensed prostitutes, and 115 male sufferers from STDs. The level of knowledge of these diseases was very high among the prostitutes and the bar hostesses, except that little was known about syphilis by the bar hostesses; the male sufferers were relatively ignorant concerning both syphilis and AIDS. Medical and paramedical personnel do not figure among the sources given for knowledge of STDs. On the other hand, friends play an important role in this knowledge, especially among unlicensed prostitutes. The second most frequently instanced source was radio and TV. The bar hostesses and the unlicensed prostitutes often exhibited distinct social characteristics. Neither education nor marriage appeared to prevent men from contracting STDs. The use of condoms is extremely rare among STD patients and not very common among unlicensed prostitutes. Half the bar hostesses report their frequent use. PMID:2611976
NASA Technical Reports Server (NTRS)
2002-01-01
Goddard Space Flight Center and Triangle Research & Development Corporation collaborated to create "Smart Eyes," a charge coupled device camera that, for the first time, could read and measure bar codes without the use of lasers. The camera operated in conjunction with software and algorithms created by Goddard and Triangle R&D that could track bar code position and direction with speed and precision, as well as with software that could control robotic actions based on vision system input. This accomplishment was intended for robotic assembly of the International Space Station, helping NASA to increase production while using less manpower. After successfully completing the two- phase SBIR project with Goddard, Triangle R&D was awarded a separate contract from the U.S. Department of Transportation (DOT), which was interested in using the newly developed NASA camera technology to heighten automotive safety standards. In 1990, Triangle R&D and the DOT developed a mask made from a synthetic, plastic skin covering to measure facial lacerations resulting from automobile accidents. By pairing NASA's camera technology with Triangle R&D's and the DOT's newly developed mask, a system that could provide repeatable, computerized evaluations of laceration injury was born.
MetaBar - a tool for consistent contextual data acquisition and standards compliant submission.
Hankeln, Wolfgang; Buttigieg, Pier Luigi; Fink, Dennis; Kottmann, Renzo; Yilmaz, Pelin; Glöckner, Frank Oliver
2010-06-30
Environmental sequence datasets are increasing at an exponential rate; however, the vast majority of them lack appropriate descriptors like sampling location, time and depth/altitude: generally referred to as metadata or contextual data. The consistent capture and structured submission of these data is crucial for integrated data analysis and ecosystems modeling. The application MetaBar has been developed, to support consistent contextual data acquisition. MetaBar is a spreadsheet and web-based software tool designed to assist users in the consistent acquisition, electronic storage, and submission of contextual data associated to their samples. A preconfigured Microsoft Excel spreadsheet is used to initiate structured contextual data storage in the field or laboratory. Each sample is given a unique identifier and at any stage the sheets can be uploaded to the MetaBar database server. To label samples, identifiers can be printed as barcodes. An intuitive web interface provides quick access to the contextual data in the MetaBar database as well as user and project management capabilities. Export functions facilitate contextual and sequence data submission to the International Nucleotide Sequence Database Collaboration (INSDC), comprising of the DNA DataBase of Japan (DDBJ), the European Molecular Biology Laboratory database (EMBL) and GenBank. MetaBar requests and stores contextual data in compliance to the Genomic Standards Consortium specifications. The MetaBar open source code base for local installation is available under the GNU General Public License version 3 (GNU GPL3). The MetaBar software supports the typical workflow from data acquisition and field-sampling to contextual data enriched sequence submission to an INSDC database. The integration with the megx.net marine Ecological Genomics database and portal facilitates georeferenced data integration and metadata-based comparisons of sampling sites as well as interactive data visualization. The ample export functionalities and the INSDC submission support enable exchange of data across disciplines and safeguarding contextual data.
MetaBar - a tool for consistent contextual data acquisition and standards compliant submission
2010-01-01
Background Environmental sequence datasets are increasing at an exponential rate; however, the vast majority of them lack appropriate descriptors like sampling location, time and depth/altitude: generally referred to as metadata or contextual data. The consistent capture and structured submission of these data is crucial for integrated data analysis and ecosystems modeling. The application MetaBar has been developed, to support consistent contextual data acquisition. Results MetaBar is a spreadsheet and web-based software tool designed to assist users in the consistent acquisition, electronic storage, and submission of contextual data associated to their samples. A preconfigured Microsoft® Excel® spreadsheet is used to initiate structured contextual data storage in the field or laboratory. Each sample is given a unique identifier and at any stage the sheets can be uploaded to the MetaBar database server. To label samples, identifiers can be printed as barcodes. An intuitive web interface provides quick access to the contextual data in the MetaBar database as well as user and project management capabilities. Export functions facilitate contextual and sequence data submission to the International Nucleotide Sequence Database Collaboration (INSDC), comprising of the DNA DataBase of Japan (DDBJ), the European Molecular Biology Laboratory database (EMBL) and GenBank. MetaBar requests and stores contextual data in compliance to the Genomic Standards Consortium specifications. The MetaBar open source code base for local installation is available under the GNU General Public License version 3 (GNU GPL3). Conclusion The MetaBar software supports the typical workflow from data acquisition and field-sampling to contextual data enriched sequence submission to an INSDC database. The integration with the megx.net marine Ecological Genomics database and portal facilitates georeferenced data integration and metadata-based comparisons of sampling sites as well as interactive data visualization. The ample export functionalities and the INSDC submission support enable exchange of data across disciplines and safeguarding contextual data. PMID:20591175
Are Technology Interruptions Impacting Your Bottom Line? An Innovative Proposal for Change.
Ledbetter, Tamera; Shultz, Sarah; Beckham, Roxanne
2017-10-01
Nursing interruptions are a costly and dangerous variable in acute care hospitals. Malfunctioning technology equipment interrupts nursing care and prevents full utilization of computer safety systems to prevent patient care errors. This paper identifies an innovative approach to nursing interruptions related to computer and computer cart malfunctions. The impact on human resources is defined and outcome measures were proposed. A multifaceted proposal, based on a literature review, aimed at reducing nursing interruptions is presented. This proposal is expected to increase patient safety, as well as patient and nurse satisfaction. Acute care hospitals utilizing electronic medical records and bar-coded medication administration technology. Nurses, information technology staff, nursing informatics staff, and all leadership teams affected by technology problems and their proposed solutions. Literature from multiple fields was reviewed to evaluate research related to computer/computer cart failures, and the approaches used to resolve these issues. Outcome measured strategic goals related to patient safety, and nurse and patient satisfaction. Specific help desk metrics will demonstrate the effect of interventions. This paper addresses a gap in the literature and proposes practical and innovative solutions. A comprehensive computer and computer cart repair program is essential for patient safety, financial stewardship, and utilization of resources. © 2015 Wiley Periodicals, Inc.
Radiology and Ethics Education.
Camargo, Aline; Liu, Li; Yousem, David M
2017-09-01
The purpose of this study is to assess medical ethics knowledge among trainees and practicing radiologists through an online survey that included questions about the American College of Radiology Code of Ethics and the American Medical Association Code of Medical Ethics. Most survey respondents reported that they had never read the American Medical Association Code of Medical Ethics or the American College of Radiology Code of Ethics (77.2% and 67.4% of respondents, respectively). With regard to ethics education during medical school and residency, 57.3% and 70.0% of respondents, respectively, found such education to be insufficient. Medical ethics training should be highlighted during residency, at specialty society meetings, and in journals and online resources for radiologists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stanford, J.
The purpose of this student annual meeting is to address topics that are becoming more relevant to medical physicists, but are not frequently addressed, especially for students and trainees just entering the field. The talk is divided into two parts: medical billing and regulations. Hsinshun Wu – Why should we learn radiation oncology billing? Many medical physicists do not like to be involved with medical billing or coding during their career. They believe billing is not their responsibility and sometimes they even refuse to participate in the billing process if given the chance. This presentation will talk about a physicist’smore » long career and share his own experience that knowing medical billing is not only important and necessary for every young medical physicist, but that good billing knowledge could provide a valuable contribution to his/her medical physics development. Learning Objectives: The audience will learn the basic definition of Current Procedural Terminology (CPT) codes performed in a Radiation Oncology Department. Understand the differences between hospital coding and physician-based or freestanding coding. Apply proper CPT coding for each Radiation Oncology procedure. Each procedure with its specific CPT code will be discussed in detail. The talk will focus on the process of care and use of actual workflow to understand each CPT code. Example coding of a typical Radiation Oncology procedure. Special procedure coding such as brachytherapy, proton therapy, radiosurgery, and SBRT. Maryann Abogunde – Medical physics opportunities at the Nuclear Regulatory Commission (NRC) The NRC’s responsibilities include the regulation of medical uses of byproduct (radioactive) materials and oversight of medical use end-users (licensees) through a combination of regulatory requirements, licensing, safety oversight including inspection and enforcement, operational experience evaluation, and regulatory support activities. This presentation will explore the career options for medical physicists in the NRC, how the NRC interacts with clinical medical physicists, and a physicist’s experience as a regulator. Learning Objectives: Explore non-clinical career pathways for medical physics students and trainees at the Nuclear Regulatory Commission. Overview of NRC medical applications and medical use regulations. Understand the skills needed for physicists as regulators. Abogunde is funded to attend the meeting by her employer, the NRC.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodrigues, A.
The purpose of this student annual meeting is to address topics that are becoming more relevant to medical physicists, but are not frequently addressed, especially for students and trainees just entering the field. The talk is divided into two parts: medical billing and regulations. Hsinshun Wu – Why should we learn radiation oncology billing? Many medical physicists do not like to be involved with medical billing or coding during their career. They believe billing is not their responsibility and sometimes they even refuse to participate in the billing process if given the chance. This presentation will talk about a physicist’smore » long career and share his own experience that knowing medical billing is not only important and necessary for every young medical physicist, but that good billing knowledge could provide a valuable contribution to his/her medical physics development. Learning Objectives: The audience will learn the basic definition of Current Procedural Terminology (CPT) codes performed in a Radiation Oncology Department. Understand the differences between hospital coding and physician-based or freestanding coding. Apply proper CPT coding for each Radiation Oncology procedure. Each procedure with its specific CPT code will be discussed in detail. The talk will focus on the process of care and use of actual workflow to understand each CPT code. Example coding of a typical Radiation Oncology procedure. Special procedure coding such as brachytherapy, proton therapy, radiosurgery, and SBRT. Maryann Abogunde – Medical physics opportunities at the Nuclear Regulatory Commission (NRC) The NRC’s responsibilities include the regulation of medical uses of byproduct (radioactive) materials and oversight of medical use end-users (licensees) through a combination of regulatory requirements, licensing, safety oversight including inspection and enforcement, operational experience evaluation, and regulatory support activities. This presentation will explore the career options for medical physicists in the NRC, how the NRC interacts with clinical medical physicists, and a physicist’s experience as a regulator. Learning Objectives: Explore non-clinical career pathways for medical physics students and trainees at the Nuclear Regulatory Commission. Overview of NRC medical applications and medical use regulations. Understand the skills needed for physicists as regulators. Abogunde is funded to attend the meeting by her employer, the NRC.« less
Siderits, Richard; Yates, Stacy; Rodriguez, Arelis; Lee, Tina; Rimmer, Cheryl; Roche, Mark
2011-01-01
Quick Response (QR) Codes are standard in supply management and seen with increasing frequency in advertisements. They are now present regularly in healthcare informatics and education. These 2-dimensional square bar codes, originally designed by the Toyota car company, are free of license and have a published international standard. The codes can be generated by free online software and the resulting images incorporated into presentations. The images can be scanned by "smart" phones and tablets using either the iOS or Android platforms, which link the device with the information represented by the QR code (uniform resource locator or URL, online video, text, v-calendar entries, short message service [SMS] and formatted text). Once linked to the device, the information can be viewed at any time after the original presentation, saved in the device or to a Web-based "cloud" repository, printed, or shared with others via email or Bluetooth file transfer. This paper describes how we use QR codes in our tumor board presentations, discusses the benefits, the different QR codes from Web links and how QR codes facilitate the distribution of educational content.
Improved Software to Browse the Serial Medical Images for Learning
2017-01-01
The thousands of serial images used for medical pedagogy cannot be included in a printed book; they also cannot be efficiently handled by ordinary image viewer software. The purpose of this study was to provide browsing software to grasp serial medical images efficiently. The primary function of the newly programmed software was to select images using 3 types of interfaces: buttons or a horizontal scroll bar, a vertical scroll bar, and a checkbox. The secondary function was to show the names of the structures that had been outlined on the images. To confirm the functions of the software, 3 different types of image data of cadavers (sectioned and outlined images, volume models of the stomach, and photos of the dissected knees) were inputted. The browsing software was downloadable for free from the homepage (anatomy.co.kr) and available off-line. The data sets provided could be replaced by any developers for their educational achievements. We anticipate that the software will contribute to medical education by allowing users to browse a variety of images. PMID:28581279
WASP: A flexible FORTRAN 4 computer code for calculating water and steam properties
NASA Technical Reports Server (NTRS)
Hendricks, R. C.; Peller, I. C.; Baron, A. K.
1973-01-01
A FORTRAN 4 subprogram, WASP, was developed to calculate the thermodynamic and transport properties of water and steam. The temperature range is from the triple point to 1750 K, and the pressure range is from 0.1 to 100 MN/m2 (1 to 1000 bars) for the thermodynamic properties and to 50 MN/m2 (500 bars) for thermal conductivity and to 80 MN/m2 (800 bars) for viscosity. WASP accepts any two of pressure, temperature, and density as input conditions. In addition, pressure and either entropy or enthalpy are also allowable input variables. This flexibility is especially useful in cycle analysis. The properties available in any combination as output include temperature, density, pressure, entropy, enthalpy, specific heats, sonic velocity, viscosity, thermal conductivity, surface tension, and the Laplace constant. The subroutine structure is modular so that the user can choose only those subroutines necessary to his calculations. Metastable calculations can also be made by using WASP.
Monzen, Hajime; Kubo, Kazuki; Tamura, Mikoto; Hayakawa, Masaru; Nishimura, Yasumasa
2017-05-01
We developed a novel low-radiation-absorbent lok-bar (HM-bar) that is used to secure the immobilizers to the couch. The aim of this study was to investigate the X-ray scattering and absorption properties of the HM-bar in computed tomography (CT) simulation and radiotherapy dose delivery using the Varian Exact™ lok-bar (VL-bar) as a benchmark. CT images were obtained with or without lok-bar, and then each image was visually evaluated for artifacts. The attenuation rates for each lok-bar were measured using a farmer-type ionization chamber (PTW30013) and the I'mRT phantom (IBA Dosimetry GmbH). Measurement points were between gantry angles of 110 and 180°. The treatment apparatus was a NovalisTx (Brainlab AG); X-ray energies were set at 6 MV and 10 MV. In the presence of each lok-bar, the radiation dose was measured in accordance with 10 volumetric modulated arc therapy-stereotactic body radiation therapy (VMAT-SBRT) plans for lung cancer. Artifacts were seldom observed in the CT scans of the HM-bar. The attenuation rate of each lok-bar was higher when the X-ray energy was set at 6 MV than at 10 MV. The highest attenuation rate in the VL-bar was observed at a gantry angle of 112°; the rates were 22.4% at 6 MV and 19.3% at 10 MV. Similarly, the highest attenuation rate for the HM-bar was also observed at a gantry angle of 112°; the rates were 12.2% and 10.1% at 6 MV and 10 MV, respectively. When the VL-bar was evaluated, the isocenter dose of the VMAT-SBRT plans was attenuated by 2.6% as a maximum case. In the case of the HM-bar, the maximum attenuation was 1.4%. In the measurements of each VMAT-SBRT plan, the difference of the dose attenuation rate between the VL-bar and HM-bar was approximately 1%. The HM-bar could be used to minimize the occurrence of artifacts and provide good images in CT scans regarding radiotherapy planning and dose calculation. It can be used for patient therapy at hospitals to provide accurate dose delivery because of its low X-ray scattering and absorption characteristics. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Effect of a viscous fiber bar on postprandial glycemia in subjects with type 2 diabetes.
Flammang, Ann M; Kendall, David M; Baumgartner, C John; Slagle, Trish D; Choe, Yong S
2006-10-01
To compare the effect of an experimental viscous fiber (VF) crispy bar on the postprandial glucose, insulin, and C-peptide response in adult subjects with type 2 diabetes to two commercially available control crispy bars. The study was a randomized, double-blinded, three period, crossover study. The study was conducted at two sites: Park Nicollet Institute, International Diabetes Center, Minneapolis, MN, and Radiant Research, Inc., Minneapolis, MN. A total of 60 adults with type 2 diabetes taking oral antihyperglycemic medication participated in the study. After an overnight fast, subjects consumed a test meal containing an equicaloric amount (300 kcal) of an experimental VF crispy bar or one of two commercially available crispy bars at each of three test visits, followed by a four hour meal tolerance test. Subjects also completed gastrointestinal (GI) response records for the 24 hours following each test visit. The VF crispy bars produced significantly lower glucose (p < 0.0001), insulin (p < 0.0001), and C-peptide (p < 0.0001) responses (as measured by positive area under the curve) in subjects with type 2 diabetes, as compared with the two commercially available bars. Intensity (p < 0.05) and frequency (p < 0.05) of flatulence were significantly higher with the VF bar as compared with the 2 commercial bars. While the VF bar produced significant subjective GI tolerance scoring values, the mean value was below 3 on a scale of 0 (no effect) to 10 (most severe effect) for all tested materials. The incorporation of VF into a crispy bar provided a means to improve blood glucose levels by reducing postprandial glucose, insulin, and C-peptide responses in subjects with type 2 diabetes. Though associated with some GI symptoms, VF may have application in improving the postprandial glycemic response in people with diabetes attempting intensive glucose control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The purpose of this student annual meeting is to address topics that are becoming more relevant to medical physicists, but are not frequently addressed, especially for students and trainees just entering the field. The talk is divided into two parts: medical billing and regulations. Hsinshun Wu – Why should we learn radiation oncology billing? Many medical physicists do not like to be involved with medical billing or coding during their career. They believe billing is not their responsibility and sometimes they even refuse to participate in the billing process if given the chance. This presentation will talk about a physicist’smore » long career and share his own experience that knowing medical billing is not only important and necessary for every young medical physicist, but that good billing knowledge could provide a valuable contribution to his/her medical physics development. Learning Objectives: The audience will learn the basic definition of Current Procedural Terminology (CPT) codes performed in a Radiation Oncology Department. Understand the differences between hospital coding and physician-based or freestanding coding. Apply proper CPT coding for each Radiation Oncology procedure. Each procedure with its specific CPT code will be discussed in detail. The talk will focus on the process of care and use of actual workflow to understand each CPT code. Example coding of a typical Radiation Oncology procedure. Special procedure coding such as brachytherapy, proton therapy, radiosurgery, and SBRT. Maryann Abogunde – Medical physics opportunities at the Nuclear Regulatory Commission (NRC) The NRC’s responsibilities include the regulation of medical uses of byproduct (radioactive) materials and oversight of medical use end-users (licensees) through a combination of regulatory requirements, licensing, safety oversight including inspection and enforcement, operational experience evaluation, and regulatory support activities. This presentation will explore the career options for medical physicists in the NRC, how the NRC interacts with clinical medical physicists, and a physicist’s experience as a regulator. Learning Objectives: Explore non-clinical career pathways for medical physics students and trainees at the Nuclear Regulatory Commission. Overview of NRC medical applications and medical use regulations. Understand the skills needed for physicists as regulators. Abogunde is funded to attend the meeting by her employer, the NRC.« less
SU-A-210-02: Medical Physics Opportunities at the NRC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abogunde, M.
The purpose of this student annual meeting is to address topics that are becoming more relevant to medical physicists, but are not frequently addressed, especially for students and trainees just entering the field. The talk is divided into two parts: medical billing and regulations. Hsinshun Wu – Why should we learn radiation oncology billing? Many medical physicists do not like to be involved with medical billing or coding during their career. They believe billing is not their responsibility and sometimes they even refuse to participate in the billing process if given the chance. This presentation will talk about a physicist’smore » long career and share his own experience that knowing medical billing is not only important and necessary for every young medical physicist, but that good billing knowledge could provide a valuable contribution to his/her medical physics development. Learning Objectives: The audience will learn the basic definition of Current Procedural Terminology (CPT) codes performed in a Radiation Oncology Department. Understand the differences between hospital coding and physician-based or freestanding coding. Apply proper CPT coding for each Radiation Oncology procedure. Each procedure with its specific CPT code will be discussed in detail. The talk will focus on the process of care and use of actual workflow to understand each CPT code. Example coding of a typical Radiation Oncology procedure. Special procedure coding such as brachytherapy, proton therapy, radiosurgery, and SBRT. Maryann Abogunde – Medical physics opportunities at the Nuclear Regulatory Commission (NRC) The NRC’s responsibilities include the regulation of medical uses of byproduct (radioactive) materials and oversight of medical use end-users (licensees) through a combination of regulatory requirements, licensing, safety oversight including inspection and enforcement, operational experience evaluation, and regulatory support activities. This presentation will explore the career options for medical physicists in the NRC, how the NRC interacts with clinical medical physicists, and a physicist’s experience as a regulator. Learning Objectives: Explore non-clinical career pathways for medical physics students and trainees at the Nuclear Regulatory Commission. Overview of NRC medical applications and medical use regulations. Understand the skills needed for physicists as regulators. Abogunde is funded to attend the meeting by her employer, the NRC.« less
... Bar Home Current Issue Past Issues Introducing medlineplus.gov Past Issues / Fall 2006 Table of Contents For ... Discover a world of FREE medical resources: medlineplus.gov Your gateway to the world's most comprehensive and ...
NASA Technical Reports Server (NTRS)
1998-01-01
Under a NASA Space Act Agreement with Marshall Space Flight Center, Symbology Research Center commercialized a new method of identifying products with invisible and virtually indestructible markings. This digital data matrix technology was developed at Marshall Space Flight Center to identify the millions of parts that comprise space shuttles. The laser-etched markings are seen as the next generation of product "bar codes."
Automatic and Controlled Attention Processes in Auditory Detection.
1981-02-01
DC 20380 1 Dr. Genevieve Hddad Progri Manager 1 Special Assistant for Marine Life Sciences Directorate Corps Matters AFOBR Code lOOM Bolling AFB, DC...INC. UIVERSITY PLAZA, SUM 10 1 Dr. Kenneth B. Cross O1160 0. STATE ST. Macape Sciences, Inc. OREM, Ur 84057 P.O. Drawer Ql i anta Bar ara,0 Dr. Pat
SU-A-210-01: Why Should We Learn Radiation Oncology Billing?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, H.
The purpose of this student annual meeting is to address topics that are becoming more relevant to medical physicists, but are not frequently addressed, especially for students and trainees just entering the field. The talk is divided into two parts: medical billing and regulations. Hsinshun Wu – Why should we learn radiation oncology billing? Many medical physicists do not like to be involved with medical billing or coding during their career. They believe billing is not their responsibility and sometimes they even refuse to participate in the billing process if given the chance. This presentation will talk about a physicist’smore » long career and share his own experience that knowing medical billing is not only important and necessary for every young medical physicist, but that good billing knowledge could provide a valuable contribution to his/her medical physics development. Learning Objectives: The audience will learn the basic definition of Current Procedural Terminology (CPT) codes performed in a Radiation Oncology Department. Understand the differences between hospital coding and physician-based or freestanding coding. Apply proper CPT coding for each Radiation Oncology procedure. Each procedure with its specific CPT code will be discussed in detail. The talk will focus on the process of care and use of actual workflow to understand each CPT code. Example coding of a typical Radiation Oncology procedure. Special procedure coding such as brachytherapy, proton therapy, radiosurgery, and SBRT. Maryann Abogunde – Medical physics opportunities at the Nuclear Regulatory Commission (NRC) The NRC’s responsibilities include the regulation of medical uses of byproduct (radioactive) materials and oversight of medical use end-users (licensees) through a combination of regulatory requirements, licensing, safety oversight including inspection and enforcement, operational experience evaluation, and regulatory support activities. This presentation will explore the career options for medical physicists in the NRC, how the NRC interacts with clinical medical physicists, and a physicist’s experience as a regulator. Learning Objectives: Explore non-clinical career pathways for medical physics students and trainees at the Nuclear Regulatory Commission. Overview of NRC medical applications and medical use regulations. Understand the skills needed for physicists as regulators. Abogunde is funded to attend the meeting by her employer, the NRC.« less
Determination of the Complex Elastic Moduli of Materials Using A Free- Free Bar Technique
1994-03-01
LCDR, Dr. D. L alner 1 Dept. of Physics (Code PH) Naval Postgrdumt School Monterey, CA 93943 10 . Cgimd Ofric. Naval Reserh Labrary ATI’N: Dr. N...Postgraduate School ( fAp~hicbl) Naval Postgraduate School 6c. ADDRESS MclY- $Mae, 02t c7;w 3 7b. ADDRESS (city, MUk and ii? code) Mogntere CA 93943-5=0...Monery CA 93943-5000 Sa. NAME OF FUNDDOISIONS0R]NG G. OFMiCE SYMBOL 9. FUU1ENIICMN IDTFCTONNUMBER ORGANUAT1ON j (If Appkiabie) NSWC. CRANE. NPS
[Towards a new Tunisian Medical Code of Deontology].
Aissaoui, Abir; Haj Salem, Nidhal; Chadly, Ali
2010-06-01
The Medical Code of Deontology is a legal text including the physician's duties towards his patients, colleagues, auxiliaries and the community. Considering the scientific, legal and social changes, the deontology code should be revised periodically. The first Tunisian Medical Code of Deontology (TMCD) was promulgated in 1973 and abrogated in 1993 by the new Code. This version has never been reviewed and does not seem to fit the current conditions of medical practice. The TMCD does not contain texts referring to information given to the patient, pain control, palliative care and management of the end of life as well as protection of medical data. Furthermore, the TMCD does not include rules related to tissues and organs transplantation and medical assisted human reproduction in accordance with Tunisian legal texts. We aim in this paper at analyzing the insufficiencies of the TMCD and suggesting modifications in order to update it.
Modeling of concrete cracking due to corrosion process of reinforcement bars
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bossio, Antonio, E-mail: antonio.bossio@unina.it; Monetta, Tullio, E-mail: monetta@unina.it; Bellucci, Francesco, E-mail: bellucci@unina.it
The reinforcement corrosion in Reinforced Concrete (RC) is a major reason of degradation for structures and infrastructures throughout the world leading to their premature deterioration before design life was attained. The effects of corrosion of reinforcement are: (i) the reduction of the cross section of the bars, and (ii) the development of corrosion products leading to the appearance of cracks in the concrete cover and subsequent cover spalling. Due to their intrinsic complex nature, these issues require an interdisciplinary approach involving both material science and structural design knowledge also in terms on International and National codes that implemented the conceptmore » of durability and service life of structures. In this paper preliminary FEM analyses were performed in order to simulate pitting corrosion or general corrosion aimed to demonstrate the possibility to extend the results obtained for a cylindrical specimen, reinforced by a single bar, to more complex RC members in terms of geometry and reinforcement. Furthermore, a mechanical analytical model to evaluate the stresses in the concrete surrounding the reinforcement bars is proposed. In addition, a sophisticated model is presented to evaluate the non-linear development of stresses inside concrete and crack propagation when reinforcement bars start to corrode. The relationships between the cracking development (mechanical) and the reduction of the steel section (electrochemical) are provided. Finally, numerical findings reported in this paper were compared to experimental results available in the literature and satisfactory agreement was found.« less
Turbulent dispersion of the icing cloud from spray nozzles used in icing tunnels
NASA Technical Reports Server (NTRS)
Marek, C. J.; Olsen, W. A., Jr.
1986-01-01
To correctly simulate flight in natural icing conditions, the turbulence in an icing simulator must be as low as possible. But some turbulence is required to mix the droplets from the spray nozzles and achieve an icing cloud of uniform liquid water content. The goal for any spray system is to obtain the widest possible spray cloud with the lowest possible turbulence in the test section of a icing tunnel. This investigation reports the measurement of turbulence and the three-dimensional spread of the cloud from a single spray nozzle. The task was to determine how the air turbulence and cloud width are affected by spray bars of quite different drag coefficients, by changes in the turbulence upstream of the spray, the droplet size, and the atomizing air. An ice accretion grid, located 6.3 m downstream of the single spray nozzle, was used to measure cloud spread. Both the spray bar and the grid were located in the constant velocity test section. Three spray bar shapes were tested: the short blunt spray bar used in the NASA Lewis Icing Research Tunnel, a thin 14.6 cm chord airfoil, and a 53 cm chord NACA 0012 airfoil. At the low airspeed (56 km/hr) the ice accretion pattern was axisymmetric and was not affected by the shape of the spray bar. At the high airspeed (169 km/hr) the spread was 30 percent smaller than at the low airspeed. For the widest cloud the spray bars should be located as far upstream in the low velocity plenum of the icing tunnel. Good comparison is obtained between the cloud spread data and predicitons from a two-dimensional cloud mixing computer code using the two equation turbulence (k epsilon g) model.
McDaniel, Patricia A; Offen, Naphtali; Yerger, Valerie; Forsyth, Susan; Malone, Ruth E
2015-08-08
News media are key sources of information regarding tobacco issues, and help set the tobacco control policy agenda. We examined US news coverage of voluntarily smokefree restaurants and bars in locales without mandatory policies to understand how such initiatives are perceived. We searched three online media databases (Access World News, Lexis Nexis, and Proquest) for all news items, including opinion pieces, published from 1995 to 2011. We coded retrieved items quantitatively, analyzing the volume, type, provenance, prominence, and content of news coverage. We found 986 news items, most published in local newspapers. News items conveyed unambiguous support for voluntarily smokefree establishments, regardless of venue. Mandatory policies were also frequently mentioned, and portrayed positively or neutrally. Restaurant items were more likely to mention health-related benefits of going smokefree, with bar items more likely to mention business-related benefits. Voluntary smokefree rules in bars and restaurants are regarded by news media as reasonable responses to health and business-based concerns about worker and customer exposure to secondhand smoke. As efforts continue to enact comprehensive smokefree policies to protect all in such venues, the media are likely to be supportive partners in the advocacy process, helping to generate public and policymaker support.
Novel designs for application specific MEMS pressure sensors.
Fragiacomo, Giulio; Reck, Kasper; Lorenzen, Lasse; Thomsen, Erik V
2010-01-01
In the framework of developing innovative microfabricated pressure sensors, we present here three designs based on different readout principles, each one tailored for a specific application. A touch mode capacitive pressure sensor with high sensitivity (14 pF/bar), low temperature dependence and high capacitive output signal (more than 100 pF) is depicted. An optical pressure sensor intrinsically immune to electromagnetic interference, with large pressure range (0-350 bar) and a sensitivity of 1 pm/bar is presented. Finally, a resonating wireless pressure sensor power source free with a sensitivity of 650 KHz/mmHg is described. These sensors will be related with their applications in harsh environment, distributed systems and medical environment, respectively. For many aspects, commercially available sensors, which in vast majority are piezoresistive, are not suited for the applications proposed.
NASA Astrophysics Data System (ADS)
Consolandi, Guido
2017-04-01
The evolution of galaxies can be thought as the result of the cumulative effects of two broad classes of processes: (i) secular (internal) processes determined by the very nature of the galaxy, and (ii) external processes that are determined by the environment in which the object is embedded. In this thesis I face both aspects of galaxy evolution. Among secular processes, I investigated the effects of stellar bars on the gaseous components of galaxies and their consequences on their evolution. In particular I show how bars affect both the ionized and cold gas in two different samples: the sample of the Halpha3 survey, an Halpha imaging survey of galaxies selected from ALFALFA in the Local and Coma superclusters; the Herschel Reference Sample, a representative sample of 323 local galaxies observed with the space-based Herschel observatory sensitive to the far-infrared emission of dust, a good tracer of cold gas. Owing to the Halpha3 data I demonstrate that main sequence barred galaxies have specific star formation rate suppressed with respect to pure disks. Here I propose a simple model in which bars drive the evolution of disk galaxies. Hydrodynamical simulations indeed show that a barred potential funnels the gas inside the corotation radius toward the center of the galaxy where it reaches high densities, cools and can be consumed by a burst of star formation. At the same time the dynamical torque of the bar keeps the gas outside the corotation radius in place, cutting the gas supply to the central region that consequently stops its star formation activity. Taking advantage of the images of the HRS sample, we show the evidences of such quenching. The aforementioned model is further tested by studying the stellar population properties of galaxies belonging to a sample of 6000 galaxies extracted from SDSS. To this aim, I designed in-house IDL codes that automatically perform aperture photometry and isophotal fitting recovering reliable magnitudes, colors, ellipticity, position angle (P.A.) and color pr! ofiles. The automatic procedure is complemented by an automatic bar finder able to extract a fairly pure sample of barred galaxies on the basis of their P.A. and ellipticity profiles. The analysis of color profiles show that disk galaxies have their central regions redder (therefore quenched) than their outer regions and that this is more evident at high mass. The high local bar fraction that we extrapolate as well as the analysis of the average color profile of barred galaxies shows the strong contribution of bars to the observed colors. In a second part, I present the work done in the field of environmental processes. The work is focused on the analysis of the observations, carried on with the IFU MUSE, of a system belonging to the nearby galaxy cluster A1367. These observations mosaicked the galaxies UGC-66967 and CGCG-97087N, two galaxies suffering ram pressure stripping and that have possibly interacted, as hinted by the presence of gas in the region between them. Owing to in-house automatic Python codes and by comparing the gas velocities to the stellar kinematics, we could separate the emission of the ionized gas in a stripped component and a component still attached to the potential of the galaxy. While the gas onboard the galaxy shows low velocity dispersions and ionizations states consistent with photoionization by stars, the stripped gas is more turbulent and ionized by shocks. The HII regions that formed in the tail of UGC-66967 (but are absent in the tail of CGCG-97087N) are systematically found in regions where the velocity dispersion of the gas is lower than 50 km/s, while the stripped gas show typical velocity dispersions about or greater than 100 km/s.
The challenge of mapping between two medical coding systems.
Wojcik, Barbara E; Stein, Catherine R; Devore, Raymond B; Hassell, L Harrison
2006-11-01
Deployable medical systems patient conditions (PCs) designate groups of patients with similar medical conditions and, therefore, similar treatment requirements. PCs are used by the U.S. military to estimate field medical resources needed in combat operations. Information associated with each of the 389 PCs is based on subject matter expert opinion, instead of direct derivation from standard medical codes. Currently, no mechanisms exist to tie current or historical medical data to PCs. Our study objective was to determine whether reliable conversion between PC codes and International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM) diagnosis codes is possible. Data were analyzed for three professional coders assigning all applicable ICD-9-CM diagnosis codes to each PC code. Inter-rater reliability was measured by using Cohen's K statistic and percent agreement. Methods were developed to calculate kappa statistics when multiple responses could be selected from many possible categories. Overall, we found moderate support for the possibility of reliable conversion between PCs and ICD-9-CM diagnoses (mean kappa = 0.61). Current PCs should be modified into a system that is verifiable with real data.
Medical Ultrasound Video Coding with H.265/HEVC Based on ROI Extraction
Wu, Yueying; Liu, Pengyu; Gao, Yuan; Jia, Kebin
2016-01-01
High-efficiency video compression technology is of primary importance to the storage and transmission of digital medical video in modern medical communication systems. To further improve the compression performance of medical ultrasound video, two innovative technologies based on diagnostic region-of-interest (ROI) extraction using the high efficiency video coding (H.265/HEVC) standard are presented in this paper. First, an effective ROI extraction algorithm based on image textural features is proposed to strengthen the applicability of ROI detection results in the H.265/HEVC quad-tree coding structure. Second, a hierarchical coding method based on transform coefficient adjustment and a quantization parameter (QP) selection process is designed to implement the otherness encoding for ROIs and non-ROIs. Experimental results demonstrate that the proposed optimization strategy significantly improves the coding performance by achieving a BD-BR reduction of 13.52% and a BD-PSNR gain of 1.16 dB on average compared to H.265/HEVC (HM15.0). The proposed medical video coding algorithm is expected to satisfy low bit-rate compression requirements for modern medical communication systems. PMID:27814367
Medical Ultrasound Video Coding with H.265/HEVC Based on ROI Extraction.
Wu, Yueying; Liu, Pengyu; Gao, Yuan; Jia, Kebin
2016-01-01
High-efficiency video compression technology is of primary importance to the storage and transmission of digital medical video in modern medical communication systems. To further improve the compression performance of medical ultrasound video, two innovative technologies based on diagnostic region-of-interest (ROI) extraction using the high efficiency video coding (H.265/HEVC) standard are presented in this paper. First, an effective ROI extraction algorithm based on image textural features is proposed to strengthen the applicability of ROI detection results in the H.265/HEVC quad-tree coding structure. Second, a hierarchical coding method based on transform coefficient adjustment and a quantization parameter (QP) selection process is designed to implement the otherness encoding for ROIs and non-ROIs. Experimental results demonstrate that the proposed optimization strategy significantly improves the coding performance by achieving a BD-BR reduction of 13.52% and a BD-PSNR gain of 1.16 dB on average compared to H.265/HEVC (HM15.0). The proposed medical video coding algorithm is expected to satisfy low bit-rate compression requirements for modern medical communication systems.
Capturing the spectrum of household food and beverage purchasing behavior: a review.
French, Simone A; Shimotsu, Scott T; Wall, Melanie; Gerlach, Anne Faricy
2008-12-01
The household setting may be the most important level at which to understand the food choices of individuals and how healthful food choices can be promoted. However, there are few available measures of the food purchase behaviors of households and little consensus on the best way to measure it. This review explores the currently available measures of household food purchasing behavior. Three main measures are described, evaluated, and compared: home food inventories, food and beverage purchase records and receipts, and Universal Product Code bar code scanning. The development of coding, aggregation, and analytical methods for these measures of household food purchasing behavior is described. Currently, annotated receipts and records are the most comprehensive, detailed measure of household food purchasing behavior, and are feasible for population-based samples. Universal Product Code scanning is not recommended due to its cost and complexity. Research directions to improve household food purchasing behavior measures are discussed.
Tsopra, Rosy; Peckham, Daniel; Beirne, Paul; Rodger, Kirsty; Callister, Matthew; White, Helen; Jais, Jean-Philippe; Ghosh, Dipansu; Whitaker, Paul; Clifton, Ian J; Wyatt, Jeremy C
2018-07-01
Coding of diagnoses is important for patient care, hospital management and research. However coding accuracy is often poor and may reflect methods of coding. This study investigates the impact of three alternative coding methods on the inaccuracy of diagnosis codes and hospital reimbursement. Comparisons of coding inaccuracy were made between a list of coded diagnoses obtained by a coder using (i)the discharge summary alone, (ii)case notes and discharge summary, and (iii)discharge summary with the addition of medical input. For each method, inaccuracy was determined for the primary, secondary diagnoses, Healthcare Resource Group (HRG) and estimated hospital reimbursement. These data were then compared with a gold standard derived by a consultant and coder. 107 consecutive patient discharges were analysed. Inaccuracy of diagnosis codes was highest when a coder used the discharge summary alone, and decreased significantly when the coder used the case notes (70% vs 58% respectively, p < 0.0001) or coded from the discharge summary with medical support (70% vs 60% respectively, p < 0.0001). When compared with the gold standard, the percentage of incorrect HRGs was 42% for discharge summary alone, 31% for coding with case notes, and 35% for coding with medical support. The three coding methods resulted in an annual estimated loss of hospital remuneration of between £1.8 M and £16.5 M. The accuracy of diagnosis codes and percentage of correct HRGs improved when coders used either case notes or medical support in addition to the discharge summary. Further emphasis needs to be placed on improving the standard of information recorded in discharge summaries. Copyright © 2018 Elsevier B.V. All rights reserved.
Star formation onset in baryonic disks: The role of a triaxial halo
NASA Astrophysics Data System (ADS)
Mazzei, P.; Curir, A.
2001-06-01
We investigate the effects of the onset of star formation on the growth of bar instability using a smooth particle hydrodynamics code implemented to account for chemo-photometric evolution from UV to near-IR wavelengths. We analyze the role of a non axisymmetric dark matter halo on the bar triggering and the feedback due to the ongoing star formation rate in the disk. We find that the dark matter halo plays a very important role in the evolution of the luminous matter. The star formation rate (SFR) depends indeed both on its mass, which leads the total gravitational field, and on its dynamical state. Stronger initial bursts of star formation are triggered in the more massive unrelaxed haloes than in the relaxed ones, which are also the more concentrated at the beginning. We point out further that the dark matter concentration is different in haloes with a different initial triaxiality ratio, suggesting a dependence of the SFR also on the halo geometry. By mapping the predicted B surface brightness of the new stars formed, we find that a luminous bar along the whole disk develops only in the first stages of such an instability, then later, new stars are born in the inner regions and the bar is reduced to the central 3-4 kpc. After 1.7 Gyr the young stellar component shows stronger bars in the presence of the relaxed haloes with a lower initial triaxiality ratio; strong bars still appear in the old star isodensity contours of the same systems, at variance with our results when star formation is switched off. The formation of new stars causes indeed a lower dynamical coupling between dark matter and baryonic particles, which lengthens the life-time of the bar. Colours and metallicity gradients of new stars allow us to understand deeply the observational consequences of initial geometry and dynamical state of the halo on the star formation process.
A Handheld Point-of-Care Genomic Diagnostic System
Myers, Frank B.; Henrikson, Richard H.; Bone, Jennifer; Lee, Luke P.
2013-01-01
The rapid detection and identification of infectious disease pathogens is a critical need for healthcare in both developed and developing countries. As we gain more insight into the genomic basis of pathogen infectivity and drug resistance, point-of-care nucleic acid testing will likely become an important tool for global health. In this paper, we present an inexpensive, handheld, battery-powered instrument designed to enable pathogen genotyping in the developing world. Our Microfluidic Biomolecular Amplification Reader (µBAR) represents the convergence of molecular biology, microfluidics, optics, and electronics technology. The µBAR is capable of carrying out isothermal nucleic acid amplification assays with real-time fluorescence readout at a fraction of the cost of conventional benchtop thermocyclers. Additionally, the µBAR features cell phone data connectivity and GPS sample geotagging which can enable epidemiological surveying and remote healthcare delivery. The µBAR controls assay temperature through an integrated resistive heater and monitors real-time fluorescence signals from 60 individual reaction chambers using LEDs and phototransistors. Assays are carried out on PDMS disposable microfluidic cartridges which require no external power for sample loading. We characterize the fluorescence detection limits, heater uniformity, and battery life of the instrument. As a proof-of-principle, we demonstrate the detection of the HIV-1 integrase gene with the µBAR using the Loop-Mediated Isothermal Amplification (LAMP) assay. Although we focus on the detection of purified DNA here, LAMP has previously been demonstrated with a range of clinical samples, and our eventual goal is to develop a microfluidic device which includes on-chip sample preparation from raw samples. The µBAR is based entirely around open source hardware and software, and in the accompanying online supplement we present a full set of schematics, bill of materials, PCB layouts, CAD drawings, and source code for the µBAR instrument with the goal of spurring further innovation toward low-cost genetic diagnostics. PMID:23936402
Celebrating Leadership in Public Health and Medicine
... Navigation Bar Home Current Issue Past Issues Celebrating Leadership in Public Health and Medicine Friends of the ... a Distinguished Medical Science Award for his global leadership in cancer research and the development of combination ...
NASA Technical Reports Server (NTRS)
1996-01-01
Building 1100 is the NASA administrative building. Services located in this building include two banks, a post office, barber shop, cafeteria, snack bar, travel agency, dry cleaners, the NASA Exchange retail store and medical facilities for employees.
Adams, Diane L.; Norman, Helen; Burroughs, Valentine J.
2002-01-01
Medical practice today, more than ever before, places greater demands on physicians to see more patients, provide more complex medical services and adhere to stricter regulatory rules, leaving little time for coding and billing. Yet, the need to adequately document medical records, appropriately apply billing codes and accurately charge insurers for medical services is essential to the medical practice's financial condition. Many physicians rely on office staff and billing companies to process their medical bills without ever reviewing the bills before they are submitted for payment. Some physicians may not be receiving the payment they deserve when they do not sufficiently oversee the medical practice's coding and billing patterns. This article emphasizes the importance of monitoring and auditing medical record documentation and coding application as a strategy for achieving compliance and reducing billing errors. When medical bills are submitted with missing and incorrect information, they may result in unpaid claims and loss of revenue to physicians. Addressing Medical Audits, Part I--A Strategy for Achieving Compliance--CMS, JCAHO, NCQA, published January 2002 in the Journal of the National Medical Association, stressed the importance of preparing the medical practice for audits. The article highlighted steps the medical practice can take to prepare for audits and presented examples of guidelines used by regulatory agencies to conduct both medical and financial audits. The Medicare Integrity Program was cited as an example of guidelines used by regulators to identify coding errors during an audit and deny payment to providers when improper billing occurs. For each denied claim, payments owed to the medical practice are are also denied. Health care is, no doubt, a costly endeavor for health care providers, consumers and insurers. The potential risk to physicians for improper billing may include loss of revenue, fraud investigations, financial sanction, disciplinary action and exclusion from participation in government programs. Part II of this article recommends an approach for assessing potential risk, preventing improper billing, and improving financial management of the medical practice. Images p432-a PMID:12078924
NASA Technical Reports Server (NTRS)
Watson, Andrew B.
1990-01-01
All vision systems, both human and machine, transform the spatial image into a coded representation. Particular codes may be optimized for efficiency or to extract useful image features. Researchers explored image codes based on primary visual cortex in man and other primates. Understanding these codes will advance the art in image coding, autonomous vision, and computational human factors. In cortex, imagery is coded by features that vary in size, orientation, and position. Researchers have devised a mathematical model of this transformation, called the Hexagonal oriented Orthogonal quadrature Pyramid (HOP). In a pyramid code, features are segregated by size into layers, with fewer features in the layers devoted to large features. Pyramid schemes provide scale invariance, and are useful for coarse-to-fine searching and for progressive transmission of images. The HOP Pyramid is novel in three respects: (1) it uses a hexagonal pixel lattice, (2) it uses oriented features, and (3) it accurately models most of the prominent aspects of primary visual cortex. The transform uses seven basic features (kernels), which may be regarded as three oriented edges, three oriented bars, and one non-oriented blob. Application of these kernels to non-overlapping seven-pixel neighborhoods yields six oriented, high-pass pyramid layers, and one low-pass (blob) layer.
Automated UMLS-Based Comparison of Medical Forms
Dugas, Martin; Fritz, Fleur; Krumm, Rainer; Breil, Bernhard
2013-01-01
Medical forms are very heterogeneous: on a European scale there are thousands of data items in several hundred different systems. To enable data exchange for clinical care and research purposes there is a need to develop interoperable documentation systems with harmonized forms for data capture. A prerequisite in this harmonization process is comparison of forms. So far – to our knowledge – an automated method for comparison of medical forms is not available. A form contains a list of data items with corresponding medical concepts. An automatic comparison needs data types, item names and especially item with these unique concept codes from medical terminologies. The scope of the proposed method is a comparison of these items by comparing their concept codes (coded in UMLS). Each data item is represented by item name, concept code and value domain. Two items are called identical, if item name, concept code and value domain are the same. Two items are called matching, if only concept code and value domain are the same. Two items are called similar, if their concept codes are the same, but the value domains are different. Based on these definitions an open-source implementation for automated comparison of medical forms in ODM format with UMLS-based semantic annotations was developed. It is available as package compareODM from http://cran.r-project.org. To evaluate this method, it was applied to a set of 7 real medical forms with 285 data items from a large public ODM repository with forms for different medical purposes (research, quality management, routine care). Comparison results were visualized with grid images and dendrograms. Automated comparison of semantically annotated medical forms is feasible. Dendrograms allow a view on clustered similar forms. The approach is scalable for a large set of real medical forms. PMID:23861827
Fifteenth NASTRAN (R) Users' Colloquium
NASA Technical Reports Server (NTRS)
1987-01-01
Numerous applications of the NASA Structural Analysis (NASTRAN) computer program, a general purpose finite element code, are discussed. Additional features that can be added to NASTRAN, interactive plotting of NASTRAN data on microcomputers, mass modeling for bars, the design of wind tunnel models, the analysis of ship structures subjected to underwater explosions, and buckling analysis of radio antennas are among the topics discussed.
The purpose of this SOP is to define the steps needed to operate the light pens, and verify the values produced by light pens used in the Arizona NHEXAS project and the "Border" study. Keywords: data; equipment; light pens.
The National Human Exposure Assessment Survey (NHEXAS)...
Ship to Shore Data Communication and Prioritization
2011-12-01
First Out FTP File Transfer Protocol GCCS-M Global Command and Control System Maritime HAIPE High Assurance Internet Protocol Encryptor HTTP Hypertext...Transfer Protocol (world wide web protocol ) IBS Integrated Bar Code System IDEF0 Integration Definition IER Information Exchange Requirements...INTEL Intelligence IP Internet Protocol IPT Integrated Product Team ISEA In-Service Engineering Agent ISNS Integrated Shipboard Network System IT
2013 R&D 100 Award: DNATrax could revolutionize air quality detection and tracking
Farquar, George
2018-01-16
A team of LLNL scientists and engineers has developed a safe and versatile material, known as DNA Tagged Reagents for Aerosol Experiments (DNATrax), that can be used to reliably and rapidly diagnose airflow patterns and problems in both indoor and outdoor venues. Until DNATrax particles were developed, no rapid or safe way existed to validate air transport models with realistic particles in the range of 1-10 microns. Successful DNATrax testing was conducted at the Pentagon in November 2012 in conjunction with the Pentagon Force Protection Agency. This study enhanced the team's understanding of indoor ventilation environments created by heating, ventilation and air conditioning (HVAC) systems. DNATrax are particles comprised of sugar and synthetic DNA that serve as a bar code for the particle. The potential for creating unique bar-coded particles is virtually unlimited, thus allowing for simultaneous and repeated releases, which dramatically reduces the costs associated with conducting tests for contaminants. Among the applications for the new material are indoor air quality detection, for homes, offices, ships and airplanes; urban particulate tracking, for subway stations, train stations, and convention centers; environmental release tracking; and oil and gas uses, including fracking, to better track fluid flow.
Product self-management: evolution in recycling and reuse.
Thomas, Valerie M
2003-12-01
This paper explores the potential to make product recycling and reuse easier by shifting responsibility for product management toward the product itself. Examples range from barcode-enabled Internet sales of used products to RFID-enabled garbage trucks that identify recyclable items and provide rebates. Initial steps toward product self-management have made opportunistic use of product bar codes and Internet markets. In the United States, Internet markets are driving increased reuse of products. In the European Union, recycling and waste management policy is driving the use of radio electronics in waste management. Prospects for product self-management are assessed from both a technological and an economic perspective. The technological analysis indicates that radio-frequency tags offer some advantages over bar codes, but their application to product self-management requires considerable investment in the waste management infrastructure. This suggests that early applications of advanced product tags are most suitable for Germany and other countries where the waste management industry has already integrated information technology into its operations. The economic analysis indicates that increased reuse of products can reduce consumption of new products and materials, although on a less than one-to-one basis, simultaneously reducing costs for consumers and deriving more value from existing products.
2013 R&D 100 Award: DNATrax could revolutionize air quality detection and tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farquar, George
A team of LLNL scientists and engineers has developed a safe and versatile material, known as DNA Tagged Reagents for Aerosol Experiments (DNATrax), that can be used to reliably and rapidly diagnose airflow patterns and problems in both indoor and outdoor venues. Until DNATrax particles were developed, no rapid or safe way existed to validate air transport models with realistic particles in the range of 1-10 microns. Successful DNATrax testing was conducted at the Pentagon in November 2012 in conjunction with the Pentagon Force Protection Agency. This study enhanced the team's understanding of indoor ventilation environments created by heating, ventilationmore » and air conditioning (HVAC) systems. DNATrax are particles comprised of sugar and synthetic DNA that serve as a bar code for the particle. The potential for creating unique bar-coded particles is virtually unlimited, thus allowing for simultaneous and repeated releases, which dramatically reduces the costs associated with conducting tests for contaminants. Among the applications for the new material are indoor air quality detection, for homes, offices, ships and airplanes; urban particulate tracking, for subway stations, train stations, and convention centers; environmental release tracking; and oil and gas uses, including fracking, to better track fluid flow.« less
The new Italian code of medical ethics.
Fineschi, V; Turillazzi, E; Cateni, C
1997-01-01
In June 1995, the Italian code of medical ethics was revised in order that its principles should reflect the ever-changing relationship between the medical profession and society and between physicians and patients. The updated code is also a response to new ethical problems created by scientific progress; the discussion of such problems often shows up a need for better understanding on the part of the medical profession itself. Medical deontology is defined as the discipline for the study of norms of conduct for the health care professions, including moral and legal norms as well as those pertaining more strictly to professional performance. The aim of deontology is therefore, the in-depth investigation and revision of the code of medical ethics. It is in the light of this conceptual definition that one should interpret a review of the different codes which have attempted, throughout the various periods of Italy's recent history, to adapt ethical norms to particular social and health care climates. PMID:9279746
New estimates of the CMB angular power spectra from the WMAP 5 year low-resolution data
NASA Astrophysics Data System (ADS)
Gruppuso, A.; de Rosa, A.; Cabella, P.; Paci, F.; Finelli, F.; Natoli, P.; de Gasperis, G.; Mandolesi, N.
2009-11-01
A quadratic maximum likelihood (QML) estimator is applied to the Wilkinson Microwave Anisotropy Probe (WMAP) 5 year low-resolution maps to compute the cosmic microwave background angular power spectra (APS) at large scales for both temperature and polarization. Estimates and error bars for the six APS are provided up to l = 32 and compared, when possible, to those obtained by the WMAP team, without finding any inconsistency. The conditional likelihood slices are also computed for the Cl of all the six power spectra from l = 2 to 10 through a pixel-based likelihood code. Both the codes treat the covariance for (T, Q, U) in a single matrix without employing any approximation. The inputs of both the codes (foreground-reduced maps, related covariances and masks) are provided by the WMAP team. The peaks of the likelihood slices are always consistent with the QML estimates within the error bars; however, an excellent agreement occurs when the QML estimates are used as a fiducial power spectrum instead of the best-fitting theoretical power spectrum. By the full computation of the conditional likelihood on the estimated spectra, the value of the temperature quadrupole CTTl=2 is found to be less than 2σ away from the WMAP 5 year Λ cold dark matter best-fitting value. The BB spectrum is found to be well consistent with zero, and upper limits on the B modes are provided. The parity odd signals TB and EB are found to be consistent with zero.
Vanishing tattoo multi-sensor for biomedical diagnostics
NASA Astrophysics Data System (ADS)
Moczko, E.; Meglinski, I.; Piletsky, S.
2008-04-01
Currently, precise non-invasive diagnostics systems for the real-time multi detection and monitoring of physiological parameters and chemical analytes in the human body are urgently required by clinicians, physiologists and bio-medical researchers. We have developed a novel cost effective smart 'vanishing tattoo' (similar to temporary child's tattoos) consisting of environmental-sensitive dyes. Painlessly impregnated into the skin the smart tattoo is capable of generating optical/fluorescence changes (absorbance, transmission, reflectance, emission and/or luminescence within UV, VIS or NIR regions) in response to physical or chemical changes. These changes allow the identification of colour pattern changes similar to bar-code scanning. Such a system allows an easy, cheap and robust comprehensive detection of various parameters and analytes in a small volume of sample (e.g. variations in pH, temperature, ionic strength, solvent polarity, presence of redox species, surfactants, oxygen). These smart tattoos have possible applications in monitoring the progress of disease and transcutaneous drug delivery. The potential of this highly innovative diagnostic tool is wide and diverse and can impact on routine clinical diagnostics, general therapeutic management, skin care and cosmetic products testing as well as fundamental physiological investigations.
Vanishing "tattoo" multisensor for biomedical diagnostics
NASA Astrophysics Data System (ADS)
Moczko, E.; Meglinski, I.; Piletsky, S.
2008-02-01
Currently, precise non-invasive diagnostics systems for the real-time multi detection and monitoring of physiological parameters and chemical analytes in the human body are urgently required by clinicians, physiologists and bio-medical researchers. We have developed a novel cost effective smart 'vanishing tattoo' (similar to temporary child's tattoos) consisting of environmental-sensitive dyes. Painlessly impregnated into the skin the smart tattoo is capable of generating optical/fluorescence changes (absorbance, transmission, reflectance, emission and/or luminescence within UV, VIS or NIR regions) in response to physical or chemical changes. These changes allow the identification of colour pattern changes similar to bar-code scanning. Such a system allows an easy, cheap and robust comprehensive detection of various parameters and analytes in a small volume of sample (e.g. variations in pH, temperature, ionic strength, solvent polarity, presence of redox species, surfactants, oxygen). These smart tattoos have possible applications in monitoring the progress of disease and transcutaneous drug delivery. The potential of this highly innovative diagnostic tool is wide and diverse and can impact on routine clinical diagnostics, general therapeutic management, skin care and cosmetic products testing as well as fundamental physiological investigations.
Printable, scannable biometric templates for secure documents and materials
NASA Astrophysics Data System (ADS)
Cambier, James L.; Musgrave, Clyde
2000-04-01
Biometric technology has been widely acknowledged as an effective means for enhancing private and public security through applications in physical access control, computer and computer network access control, medical records protection, banking security, public identification programs, and others. Nearly all of these applications involve use of a biometric token to control access to a physical entity or private information. There are also unique benefits to be derived from attaching a biometric template to a physical entity such as a document, package, laboratory sample, etc. Such an association allows fast, reliable, and highly accurate association of an individual person's identity to the physical entity, and can be used to enhance security, convenience, and privacy in many types of transactions. Examples include authentication of documents, tracking of laboratory samples in a testing environment, monitoring the movement of physical evidence within the criminal justice system, and authenticating the identity of both sending and receiving parties in shipment of high value parcels. A system is described which combines a biometric technology based on iris recognition with a printing and scanning technology for high-density bar codes.
Ruffing, T; Huchzermeier, P; Muhm, M; Winkler, H
2014-05-01
Precise coding is an essential requirement in order to generate a valid DRG. The aim of our study was to evaluate the quality of the initial coding of surgical procedures, as well as to introduce our "hybrid model" of a surgical specialist supervising medical coding and a nonphysician for case auditing. The department's DRG responsible physician as a surgical specialist has profound knowledge both in surgery and in DRG coding. At a Level 1 hospital, 1000 coded cases of surgical procedures were checked. In our department, the DRG responsible physician who is both a surgeon and encoder has proven itself for many years. The initial surgical DRG coding had to be corrected by the DRG responsible physician in 42.2% of cases. On average, one hour per working day was necessary. The implementation of a DRG responsible physician is a simple, effective way to connect medical and business expertise without interface problems. Permanent feedback promotes both medical and economic sensitivity for the improvement of coding quality.
Retief, F P; Cilliers, L
2007-01-01
Although the Mesopotamian civilisation is as old as that of Egypt and might even have predated it, we know much less about Mesopotamian medicine, mainly because the cuneiform source material is less well researched. Medical healers existed from the middle of the 3rd millennium. In line with the strong theocratic state culture, healers were closely integrated with the powerful priestly fraternity, and were essentially of three main kinds: barû (seers) who were experts in divination, âshipu (exorcists), and asû (healing priests) who tended directly to the sick. All illness was accepted as sent by gods, demons and other evil spirits, either as retribution for sins or as malevolent visitations. Treatment revolved around identification of the offending supernatural power, appeasement of the angry gods, for example by offering amulets or incantations, exorcism of evil spirits, as well as a measure of empirical therapy aimed against certain recognised symptom complexes. Medical practice was rigidly codified, starting with Hammurabi's Code in the 18th century BC and persisting to the late 1st millennium BC. Works like the so-called Diagnostic Handbook, the Assyrian Herbal and Prescription Texts describe the rationale of Mesopotamian medicine, based predominantly on supernatural concepts, although rudimentary traces of empirical medicine are discernible. There is evidence that Egyptian medicine might have been influenced by Mesopotamian practices, but Greek rational medicine as it evolved in the 5th/4th centuries BC almost certainly had no significant Mesopotamian roots.
Novel Designs for Application Specific MEMS Pressure Sensors
Fragiacomo, Giulio; Reck, Kasper; Lorenzen, Lasse; Thomsen, Erik V.
2010-01-01
In the framework of developing innovative microfabricated pressure sensors, we present here three designs based on different readout principles, each one tailored for a specific application. A touch mode capacitive pressure sensor with high sensitivity (14 pF/bar), low temperature dependence and high capacitive output signal (more than 100 pF) is depicted. An optical pressure sensor intrinsically immune to electromagnetic interference, with large pressure range (0–350 bar) and a sensitivity of 1 pm/bar is presented. Finally, a resonating wireless pressure sensor power source free with a sensitivity of 650 KHz/mmHg is described. These sensors will be related with their applications in harsh environment, distributed systems and medical environment, respectively. For many aspects, commercially available sensors, which in vast majority are piezoresistive, are not suited for the applications proposed. PMID:22163425
Aerosol Constraints on the Atmosphere of the Hot Saturn-mass Planet WASP-49b
NASA Astrophysics Data System (ADS)
Cubillos, Patricio E.; Fossati, Luca; Erkaev, Nikolai V.; Malik, Matej; Tokano, Tetsuya; Lendl, Monika; Johnstone, Colin P.; Lammer, Helmut; Wyttenbach, Aurélien
2017-11-01
The strong, nearly wavelength-independent absorption cross section of aerosols produces featureless exoplanet transmission spectra, limiting our ability to characterize their atmospheres. Here, we show that even in the presence of featureless spectra, we can still characterize certain atmospheric properties. Specifically, we constrain the upper and lower pressure boundaries of aerosol layers, and present plausible composition candidates. We study the case of the bloated Saturn-mass planet WASP-49 b, where near-infrared observations reveal a flat transmission spectrum between 0.7 and 1.0 μm. First, we use a hydrodynamic upper-atmosphere code to estimate the pressure reached by the ionizing stellar high-energy photons at {10}-8 bar, setting the upper pressure boundary where aerosols could exist. Then, we combine HELIOS and Pyrat Bay radiative-transfer models to constrain the temperature and photospheric pressure of atmospheric aerosols, in a Bayesian framework. For WASP-49 b, we constrain the transmission photosphere (hence, the aerosol deck boundaries) to pressures above {10}-5 bar (100× solar metallicity), {10}-4 bar (solar), and {10}-3 bar (0.1× solar) as the lower boundary, and below {10}-7 bar as the upper boundary. Lastly, we compare condensation curves of aerosol compounds with the planet’s pressure-temperature profile to identify plausible condensates responsible for the absorption. Under these circumstances, we find these candidates: {{Na}}2{{S}} (at 100× solar metallicity); Cr and MnS (at solar and 0.1× solar) and forsterite, enstatite, and alabandite (at 0.1× solar).
NASA Technical Reports Server (NTRS)
Derkevorkian, Armen; Peterson, Lee; Kolaini, Ali R.; Hendricks, Terry J.; Nesmith, Bill J.
2016-01-01
An analytic approach is demonstrated to reveal potential pyroshock -driven dynamic effects causing power losses in the Thermo -Electric (TE) module bars of the Mars Science Laboratory (MSL) Multi -Mission Radioisotope Thermoelectric Generator (MMRTG). This study utilizes high- fidelity finite element analysis with SIERRA/PRESTO codes to estimate wave propagation effects due to large -amplitude suddenly -applied pyro shock loads in the MMRTG. A high fidelity model of the TE module bar was created with approximately 30 million degrees -of-freedom (DOF). First, a quasi -static preload was applied on top of the TE module bar, then transient tri- axial acceleration inputs were simultaneously applied on the preloaded module. The applied input acceleration signals were measured during MMRTG shock qualification tests performed at the Jet Propulsion Laboratory. An explicit finite element solver in the SIERRA/PRESTO computational environment, along with a 3000 processor parallel super -computing framework at NASA -AMES, was used for the simulation. The simulation results were investigated both qualitatively and quantitatively. The predicted shock wave propagation results provide detailed structural responses throughout the TE module bar, and key insights into the dynamic response (i.e., loads, displacements, accelerations) of critical internal spring/piston compression systems, TE materials, and internal component interfaces in the MMRTG TE module bar. They also provide confidence on the viability of this high -fidelity modeling scheme to accurately predict shock wave propagation patterns within complex structures. This analytic approach is envisioned for modeling shock sensitive hardware susceptible to intense shock environments positioned near shock separation devices in modern space vehicles and systems.
Medical image classification based on multi-scale non-negative sparse coding.
Zhang, Ruijie; Shen, Jian; Wei, Fushan; Li, Xiong; Sangaiah, Arun Kumar
2017-11-01
With the rapid development of modern medical imaging technology, medical image classification has become more and more important in medical diagnosis and clinical practice. Conventional medical image classification algorithms usually neglect the semantic gap problem between low-level features and high-level image semantic, which will largely degrade the classification performance. To solve this problem, we propose a multi-scale non-negative sparse coding based medical image classification algorithm. Firstly, Medical images are decomposed into multiple scale layers, thus diverse visual details can be extracted from different scale layers. Secondly, for each scale layer, the non-negative sparse coding model with fisher discriminative analysis is constructed to obtain the discriminative sparse representation of medical images. Then, the obtained multi-scale non-negative sparse coding features are combined to form a multi-scale feature histogram as the final representation for a medical image. Finally, SVM classifier is combined to conduct medical image classification. The experimental results demonstrate that our proposed algorithm can effectively utilize multi-scale and contextual spatial information of medical images, reduce the semantic gap in a large degree and improve medical image classification performance. Copyright © 2017 Elsevier B.V. All rights reserved.
Information quality measurement of medical encoding support based on usability.
Puentes, John; Montagner, Julien; Lecornu, Laurent; Cauvin, Jean-Michel
2013-12-01
Medical encoding support systems for diagnoses and medical procedures are an emerging technology that begins to play a key role in billing, reimbursement, and health policies decisions. A significant problem to exploit these systems is how to measure the appropriateness of any automatically generated list of codes, in terms of fitness for use, i.e. their quality. Until now, only information retrieval performance measurements have been applied to estimate the accuracy of codes lists as quality indicator. Such measurements do not give the value of codes lists for practical medical encoding, and cannot be used to globally compare the quality of multiple codes lists. This paper defines and validates a new encoding information quality measure that addresses the problem of measuring medical codes lists quality. It is based on a usability study of how expert coders and physicians apply computer-assisted medical encoding. The proposed measure, named ADN, evaluates codes Accuracy, Dispersion and Noise, and is adapted to the variable length and content of generated codes lists, coping with limitations of previous measures. According to the ADN measure, the information quality of a codes list is fully represented by a single point, within a suitably constrained feature space. Using one scheme, our approach is reliable to measure and compare the information quality of hundreds of codes lists, showing their practical value for medical encoding. Its pertinence is demonstrated by simulation and application to real data corresponding to 502 inpatient stays in four clinic departments. Results are compared to the consensus of three expert coders who also coded this anonymized database of discharge summaries, and to five information retrieval measures. Information quality assessment applying the ADN measure showed the degree of encoding-support system variability from one clinic department to another, providing a global evaluation of quality measurement trends. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
Goomas, David T.
2008-01-01
In this report from the field, computerized auditory feedback was used to inform order selectors and order selector auditors in a distribution center to add an electronic article surveillance (EAS) adhesive tag. This was done by programming handheld computers to emit a loud beep for high-priced items upon scanning the item's bar-coded Universal…
2003-04-01
Charlottesville, Virginia. Member of the bars of Nebraska and the Court of Appeals for the Armed Forces. This article was submitted in partial completion of the...Oversight of Panel-Member Selection Process ................................. 34 1. 1789 to 1916: A Period of Limited Oversight...Code of Military Justice: New Statutory Limitations on Convening Authority Discretion
Electronic Fingerprinting for Industry
NASA Technical Reports Server (NTRS)
1995-01-01
Veritec's VeriSystem is a complete identification and tracking system for component traceability, improved manufacturing and processing, and automated shop floor applications. The system includes the Vericode Symbol, a more accurate and versatile alternative to the traditional bar code, that is scanned by charge coupled device (CCD) cameras. The system was developed by Veritec, Rockwell International and Marshall Space Flight Center to identify and track Space Shuttle parts.
DataPlus - a revolutionary applications generator for DOS hand-held computers
David Dean; Linda Dean
2000-01-01
DataPlus allows the user to easily design data collection templates for DOS-based hand-held computers that mimic clipboard data sheets. The user designs and tests the application on the desktop PC and then transfers it to a DOS field computer. Other features include: error checking, missing data checks, and sensor input from RS-232 devices such as bar code wands,...
Identifying Objects via Encased X-Ray-Fluorescent Materials - the Bar Code Inside
NASA Technical Reports Server (NTRS)
Schramm, Harry F.; Kaiser, Bruce
2005-01-01
Systems for identifying objects by means of x-ray fluorescence (XRF) of encased labeling elements have been developed. The XRF spectra of objects so labeled would be analogous to the external bar code labels now used to track objects in everyday commerce. In conjunction with computer-based tracking systems, databases, and labeling conventions, the XRF labels could be used in essentially the same manner as that of bar codes to track inventories and to record and process commercial transactions. In addition, as summarized briefly below, embedded XRF labels could be used to verify the authenticity of products, thereby helping to deter counterfeiting and fraud. A system, as described above, is called an encased core product identification and authentication system (ECPIAS). The ECPIAS concept is a modified version of that of a related recently initiated commercial development of handheld XRF spectral scanners that would identify alloys or detect labeling elements deposited on the surfaces of objects. In contrast, an ECPIAS would utilize labeling elements encased within the objects of interest. The basic ECPIAS concept is best illustrated by means of an example of one of several potential applications: labeling of cultured pearls by labeling the seed particles implanted in oysters to grow the pearls. Each pearl farmer would be assigned a unique mixture of labeling elements that could be distinguished from the corresponding mixtures of other farmers. The mixture would be either incorporated into or applied to the surfaces of the seed prior to implantation in the oyster. If necessary, the labeled seed would be further coated to make it nontoxic to the oyster. After implantation, the growth of layers of mother of pearl on the seed would encase the XRF labels, making these labels integral, permanent parts of the pearls that could not be removed without destroying the pearls themselves. The XRF labels would be read by use of XRF scanners, the spectral data outputs of which would be converted to alphanumeric data in a digital equivalent data system (DEDS), which is the subject of the previous article. These alphanumeric data would be used to track the pearls through all stages of commerce, from the farmer to the retail customer.
Hazelgrove, Jenny
2002-04-01
This article explores the impact of the Nuremberg Code on post-Second World War research ethics in Britain. Against the background of the Nuremberg Medical Trial, the Code received international endorsement, but how much did its ethical percepts influence actual research? This paper shows that, despite British involvement in the formulation of the Code, the experience of war-time and changing career structures were more influential in shaping the approach of investigators to their subjects. Where medical debates ensued, primarily over controversial research practices at the British Postgraduate Medical School, Hammersmith Hospital, they were set in the context of a much older division between 'bedside' and 'scientific' medicine. But whatever differences there may have been between those physicians who advocated research and those who questioned its use and ethical basis, most clung to the paternalist assumption that it was the doctor's place to decide what was best for his patients. Faced with rising public and medical criticism of contemporary research practices, the medical élite of the 1960s and 1970s safeguarded the reputation of the profession and medical control of research by negotiating new voluntary codes. In a similar move, their predecessors had helped to negotiate the Nuremberg Code in anticipation of public criticism of experimentation arising from the Nuremberg Medical Trial.
Maund, Emma; Tendal, Britta; Hróbjartsson, Asbjørn; Lundh, Andreas; Gøtzsche, Peter C
2014-06-04
To assess the effects of coding and coding conventions on summaries and tabulations of adverse events data on suicidality within clinical study reports. Systematic electronic search for adverse events of suicidality in tables, narratives, and listings of adverse events in individual patients within clinical study reports. Where possible, for each event we extracted the original term reported by the investigator, the term as coded by the medical coding dictionary, medical coding dictionary used, and the patient's trial identification number. Using the patient's trial identification number, we attempted to reconcile data on the same event between the different formats for presenting data on adverse events within the clinical study report. 9 randomised placebo controlled trials of duloxetine for major depressive disorder submitted to the European Medicines Agency for marketing approval. Clinical study reports obtained from the EMA in 2011. Six trials used the medical coding dictionary COSTART (Coding Symbols for a Thesaurus of Adverse Reaction Terms) and three used MedDRA (Medical Dictionary for Regulatory Activities). Suicides were clearly identifiable in all formats of adverse event data in clinical study reports. Suicide attempts presented in tables included both definitive and provisional diagnoses. Suicidal ideation and preparatory behaviour were obscured in some tables owing to the lack of specificity of the medical coding dictionary, especially COSTART. Furthermore, we found one event of suicidal ideation described in narrative text that was absent from tables and adverse event listings of individual patients. The reason for this is unclear, but may be due to the coding conventions used. Data on adverse events in tables in clinical study reports may not accurately represent the underlying patient data because of the medical dictionaries and coding conventions used. In clinical study reports, the listings of adverse events for individual patients and narratives of adverse events can provide additional information, including original investigator reported adverse event terms, which can enable a more accurate estimate of harms. © Maund et al 2014.
U.S. EPA, Pesticide Product Label, SENVITA SWEET BAR-FLY MIX NO. 133 MEDICATED, 12/27/1972
2011-04-21
.• y' " II ... ,. Ii) , : I ; " \\ , ( I " " ! ," I . , l.. _ .... I...t. , " " I" '" 'JI ,j T . , ~ 1,' , ( , I' ,. , , I " \\ I " f II I , , , . " I . I , , , , \\ l 'I " '1 , '., "1 , i ,\\ I , I , . , ". ...
Kavuluru, Ramakanth; Han, Sifei; Harris, Daniel
2017-01-01
Diagnosis codes are extracted from medical records for billing and reimbursement and for secondary uses such as quality control and cohort identification. In the US, these codes come from the standard terminology ICD-9-CM derived from the international classification of diseases (ICD). ICD-9 codes are generally extracted by trained human coders by reading all artifacts available in a patient’s medical record following specific coding guidelines. To assist coders in this manual process, this paper proposes an unsupervised ensemble approach to automatically extract ICD-9 diagnosis codes from textual narratives included in electronic medical records (EMRs). Earlier attempts on automatic extraction focused on individual documents such as radiology reports and discharge summaries. Here we use a more realistic dataset and extract ICD-9 codes from EMRs of 1000 inpatient visits at the University of Kentucky Medical Center. Using named entity recognition (NER), graph-based concept-mapping of medical concepts, and extractive text summarization techniques, we achieve an example based average recall of 0.42 with average precision 0.47; compared with a baseline of using only NER, we notice a 12% improvement in recall with the graph-based approach and a 7% improvement in precision using the extractive text summarization approach. Although diagnosis codes are complex concepts often expressed in text with significant long range non-local dependencies, our present work shows the potential of unsupervised methods in extracting a portion of codes. As such, our findings are especially relevant for code extraction tasks where obtaining large amounts of training data is difficult. PMID:28748227
Color coding of control room displays: the psychocartography of visual layering effects.
Van Laar, Darren; Deshe, Ofer
2007-06-01
To evaluate which of three color coding methods (monochrome, maximally discriminable, and visual layering) used to code four types of control room display format (bars, tables, trend, mimic) was superior in two classes of task (search, compare). It has recently been shown that color coding of visual layers, as used in cartography, may be used to color code any type of information display, but this has yet to be fully evaluated. Twenty-four people took part in a 2 (task) x 3 (coding method) x 4 (format) wholly repeated measures design. The dependent variables assessed were target location reaction time, error rates, workload, and subjective feedback. Overall, the visual layers coding method produced significantly faster reaction times than did the maximally discriminable and the monochrome methods for both the search and compare tasks. No significant difference in errors was observed between conditions for either task type. Significantly less perceived workload was experienced with the visual layers coding method, which was also rated more highly than the other coding methods on a 14-item visual display quality questionnaire. The visual layers coding method is superior to other color coding methods for control room displays when the method supports the user's task. The visual layers color coding method has wide applicability to the design of all complex information displays utilizing color coding, from the most maplike (e.g., air traffic control) to the most abstract (e.g., abstracted ecological display).
Prediction task guided representation learning of medical codes in EHR.
Cui, Liwen; Xie, Xiaolei; Shen, Zuojun
2018-06-18
There have been rapidly growing applications using machine learning models for predictive analytics in Electronic Health Records (EHR) to improve the quality of hospital services and the efficiency of healthcare resource utilization. A fundamental and crucial step in developing such models is to convert medical codes in EHR to feature vectors. These medical codes are used to represent diagnoses or procedures. Their vector representations have a tremendous impact on the performance of machine learning models. Recently, some researchers have utilized representation learning methods from Natural Language Processing (NLP) to learn vector representations of medical codes. However, most previous approaches are unsupervised, i.e. the generation of medical code vectors is independent from prediction tasks. Thus, the obtained feature vectors may be inappropriate for a specific prediction task. Moreover, unsupervised methods often require a lot of samples to obtain reliable results, but most practical problems have very limited patient samples. In this paper, we develop a new method called Prediction Task Guided Health Record Aggregation (PTGHRA), which aggregates health records guided by prediction tasks, to construct training corpus for various representation learning models. Compared with unsupervised approaches, representation learning models integrated with PTGHRA yield a significant improvement in predictive capability of generated medical code vectors, especially for limited training samples. Copyright © 2018. Published by Elsevier Inc.
Flowers, Natalie L
2010-01-01
CodeSlinger is a desktop application that was developed to aid medical professionals in the intertranslation, exploration, and use of biomedical coding schemes. The application was designed to provide a highly intuitive, easy-to-use interface that simplifies a complex business problem: a set of time-consuming, laborious tasks that were regularly performed by a group of medical professionals involving manually searching coding books, searching the Internet, and checking documentation references. A workplace observation session with a target user revealed the details of the current process and a clear understanding of the business goals of the target user group. These goals drove the design of the application's interface, which centers on searches for medical conditions and displays the codes found in the application's database that represent those conditions. The interface also allows the exploration of complex conceptual relationships across multiple coding schemes.
A Plastic Temporal Brain Code for Conscious State Generation
Dresp-Langley, Birgitta; Durup, Jean
2009-01-01
Consciousness is known to be limited in processing capacity and often described in terms of a unique processing stream across a single dimension: time. In this paper, we discuss a purely temporal pattern code, functionally decoupled from spatial signals, for conscious state generation in the brain. Arguments in favour of such a code include Dehaene et al.'s long-distance reverberation postulate, Ramachandran's remapping hypothesis, evidence for a temporal coherence index and coincidence detectors, and Grossberg's Adaptive Resonance Theory. A time-bin resonance model is developed, where temporal signatures of conscious states are generated on the basis of signal reverberation across large distances in highly plastic neural circuits. The temporal signatures are delivered by neural activity patterns which, beyond a certain statistical threshold, activate, maintain, and terminate a conscious brain state like a bar code would activate, maintain, or inactivate the electronic locks of a safe. Such temporal resonance would reflect a higher level of neural processing, independent from sensorial or perceptual brain mechanisms. PMID:19644552
Second-order closure PBL model with new third-order moments: Comparison with LES data
NASA Technical Reports Server (NTRS)
Canuto, V. M.; Minotti, F.; Ronchi, C.; Ypma, R. M.; Zeman, O.
1994-01-01
This paper contains two parts. In the first part, a new set of diagnostic equations is derived for the third-order moments for a buoyancy-driven flow, by exact inversion of the prognostic equations for the third-order moment equations in the stationary case. The third-order moments exhibit a universal structure: they all are a linear combination of the derivatives of all the second-order moments, bar-w(exp 2), bar-w theta, bar-theta(exp 2), and bar-q(exp 2). Each term of the sum contains a turbulent diffusivity D(sub t), which also exhibits a universal structure of the form D(sub t) = a nu(sub t) + b bar-w theta. Since the sign of the convective flux changes depending on stable or unstable stratification, D(sub t) varies according to the type of stratification. Here nu(sub t) approximately equal to wl (l is a mixing length and w is an rms velocity) represents the 'mechanical' part, while the 'buoyancy' part is represented by the convective flux bar-w theta. The quantities a and b are functions of the variable N(sub tau)(exp 2), where N(exp 2) = g alpha derivative of Theta with respect to z and tau is the turbulence time scale. The new expressions for the third-order moments generalize those of Zeman and Lumley, which were subsequently adopted by Sun and Ogura, Chen and Cotton, and Finger and Schmidt in their treatments of the convective boundary layer. In the second part, the new expressions for the third-order moments are used to solve the ensemble average equations describing a purely convective boundary laye r heated from below at a constant rate. The computed second- and third-order moments are then compared with the corresponding Large Eddy Simulation (LES) results, most of which are obtained by running a new LES code, and part of which are taken from published results. The ensemble average results compare favorably with the LES data.
Projection of Patient Condition Code Distributions Based on Mechanism of Injury
2003-01-01
The Medical Readiness and Strategic Plan (MRSP)1998-20041 requires that the military services develop a method for linking real world patient load...data with modern Patient Condition (PC) codes to enable planners to forecast medical workload and resource requirements. Determination of the likely...various levels of medical care. Medical planners and logisticians plan for medical contingencies based on anticipated patient streams, distributions of
Focused Logistics, Joint Vision 2010: A Joint Logistics Roadmap
2010-01-01
AIS). AIT devices include bar codes for individual items, optical memory cards for multipacks and containers, radio frequency tags for containers and...Fortezza Card and Firewall technologies are being developed to prevent unau- thorized access. As for infrastructure, DISA has already made significant in...radio frequency tags and optical memory cards , to continuously update the JTAV database. By September 1998, DSS will be deployed in all wholesale
Rule of Law in Mexico: Fact or Fiction
2011-10-28
Constitution, Article 49 10 Alex J. Gilman, “Making Amends with the Mexican Constitution: Reassessing the 1995 Judicial Reforms and Considering Prospects...fact, it’s not unusual for Mexican law professors to simply read the contents of an applicable code, regulation or article to their students instead...ramifications for student cheating or plagiarism , either. Many students “graduate” law schools without completing the thesis requirement. There are no bar
Impact of Fiber Optics on System Reliability and Maintainability
1988-06-01
200 3-23 Log-normal plot showing the general relationship between emitter lifetime and case temperature . . .. 217 Chapter 4. PHOTODECTORS AND...stereo equipment use infrared signals to transmit the control information. Infrared light is also used in security systems for motion and intrusion...detection. Most modern grocery stores have laser scanners at the checkout line to read the bar code information printed on the packages. Infrared radar
The purpose of this SOP is to define the steps needed to operate the light pens, and verify the values produced by light pens used in the Arizona NHEXAS project and the Border study. Keywords: data; equipment; light pens.
The U.S.-Mexico Border Program is sponsored by the Envir...
Gist and verbatim communication concerning medication risks/benefits.
Blalock, Susan J; DeVellis, Robert F; Chewning, Betty; Sleath, Betsy L; Reyna, Valerie F
2016-06-01
To describe the information about medication risks/benefits that rheumatologists provide during patient office visits, the gist that patients with rheumatoid arthritis (RA) extract from the information provided, and the relationship between communication and medication satisfaction. Data from 169 RA patients were analyzed. Each participant had up to three visits audiotaped. Four RA patients coded the audiotapes using a Gist Coding Scheme and research assistants coded the audiotapes using a Verbatim Coding Scheme. When extracting gist from the information discussed during visits, patient coders distinguished between discussion concerning the possibility of medication side effects versus expression of significant safety concerns. Among patients in the best health, nearly 80% reported being totally satisfied with their medications when the physician communicated the gist that the medication was effective, compared to approximately 50% when this gist was not communicated. Study findings underscore the multidimensional nature of medication risk communication and the importance of communication concerning medication effectiveness/need. Health care providers should ensure that patients understand that medication self-management practices can minimize potential risks. Communicating simple gist messages may increase patient satisfaction, especially messages about benefits for well-managed patients. Optimal communication also requires shared understanding of desired therapeutic outcomes. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Zhao, Ziyan; Henowitz, Liza; Zweifach, Adam
2018-05-01
We previously developed a flow cytometry assay that monitored lytic granule exocytosis in cytotoxic T lymphocytes stimulated by contacting beads coated with activating anti-CD3 antibodies. That assay was multiplexed in that responses of cells that did or did not receive the activating stimulus were distinguished via changes in light scatter accompanying binding of cells to beads, allowing us to discriminate compounds that activate responses on their own from compounds that enhance responses in cells that received the activating stimulus, all within a single sample. Here we add a second dimension of multiplexing by developing means to assess in a single sample the effects of treating cells with test compounds for different times. Bar-coding cells before adding them to test wells lets us determine compound treatment time while also monitoring activation status and response amplitude at the point of interrogation. This multiplexed assay is suitable for screening 96-well plates. We used it to screen compounds from the National Cancer Institute, identifying several compounds that enhance anti-LAMP1 responses. Multiple-treatment-time (MTT) screening enabled by bar-coding and read via high-throughput flow cytometry may be a generally useful method for facilitating the discovery of compounds of interest.
Delaney, Nigel F.; Marx, Christopher J.
2012-01-01
Understanding evolutionary dynamics within microbial populations requires the ability to accurately follow allele frequencies through time. Here we present a rapid, cost-effective method (FREQ-Seq) that leverages Illumina next-generation sequencing for localized, quantitative allele frequency detection. Analogous to RNA-Seq, FREQ-Seq relies upon counts from the >105 reads generated per locus per time-point to determine allele frequencies. Loci of interest are directly amplified from a mixed population via two rounds of PCR using inexpensive, user-designed oligonucleotides and a bar-coded bridging primer system that can be regenerated in-house. The resulting bar-coded PCR products contain the adapters needed for Illumina sequencing, eliminating further library preparation. We demonstrate the utility of FREQ-Seq by determining the order and dynamics of beneficial alleles that arose as a microbial population, founded with an engineered strain of Methylobacterium, evolved to grow on methanol. Quantifying allele frequencies with minimal bias down to 1% abundance allowed effective analysis of SNPs, small in-dels and insertions of transposable elements. Our data reveal large-scale clonal interference during the early stages of adaptation and illustrate the utility of FREQ-Seq as a cost-effective tool for tracking allele frequencies in populations. PMID:23118913
"Blurred lines?" Sexual aggression and barroom culture.
Graham, Kathryn; Bernards, Sharon; Wayne Osgood, D; Abbey, Antonia; Parks, Michael; Flynn, Andrea; Dumas, Tara; Wells, Samantha
2014-05-01
Meeting potential sexual/romantic partners for mutual pleasure is one of the main reasons young adults go to bars. However, not all sexual contacts are positive and consensual, and aggression related to sexual advances is a common experience. Sometimes such aggression is related to misperceptions in making and receiving sexual advances while other times aggression reflects intentional harassment or other sexually aggressive acts. This study uses objective observational research to assess quantitatively gender of initiators and targets and the extent that sexual aggression involves intentional aggression by the initiator, the nature of responses by targets, and the role of third parties and intoxication. We analyzed 258 aggressive incidents involving sexual advances observed as part of a larger study on aggression in large capacity bars and clubs, using variables collected as part of the original research (gender, intoxication, intent) and variables coded from narrative descriptions (invasiveness, persistence, targets' responses, role of third parties). Hierarchical linear modeling analyses were used to account for nesting of incidents in evening and bars. Ninety percent of incidents involved male initiators and female targets, with almost all incidents involving intentional or probably intentional aggression. Targets mostly responded nonaggressively, usually using evasion. Staff rarely intervened; patron third parties intervened in 21% of incidents, usually to help the target but sometimes to encourage the initiator. initiators' level of invasiveness was related to intoxication of the targets, but not their own intoxication, suggesting intoxicated women were being targeted. Sexual aggression is a major problem in bars often reflecting intentional sexual invasiveness and unwanted persistence rather than misperceptions in sexual advances. Prevention needs to focus on addressing masculinity norms of male patrons and staff who support sexual aggression and better management of the highly sexualized and sexist environments of most bars. Copyright © 2014 by the Research Society on Alcoholism.
Maxillomandibular Fixation by Plastic Surgeons: Cost Analysis and Utilization of Resources.
Farber, Scott J; Snyder-Warwick, Alison K; Skolnick, Gary B; Woo, Albert S; Patel, Kamlesh B
2016-09-01
Maxillomandibular fixation (MMF) can be performed using various techniques. Two common approaches used are arch bars and bone screws. Arch bars are the gold standard and inexpensive, but often require increased procedure time. Bone screws with wire fixation is a popular alternative, but more expensive than arch bars. The differences in costs of care, complications, and operative times between these 2 techniques are analyzed. A chart review was conducted on patients treated over the last 12 years at our institution. Forty-four patients with CPT code 21453 (closed reduction of mandible fracture with interdental fixation) with an isolated mandible fracture were used in our data collection. The operating room (OR) costs, procedure duration, and complications for these patients were analyzed. Operative times were significantly shorter for patients treated with bone screws (P < 0.002). The costs for one trip to the OR for either method of fixation did not show any significant differences (P < 0.840). More patients with arch bar fixation (62%) required a second trip to the OR for removal in comparison to those with screw fixation (31%) (P < 0.068). This additional trip to the OR added significant cost. There were no differences in patient complications between these 2 fixation techniques. The MMF with bone screws represents an attractive alternative to fixation with arch bars in appropriate scenarios. Screw fixation offers reduced costs, fewer trips to the OR, and decreased operative duration without a difference in complications. Cost savings were noted most significantly in a decreased need for secondary procedures in patients who were treated with MMF screws. Screw fixation offers potential for reducing the costs of care in treating patients with minimally displaced or favorable mandible fractures.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-16
... hospital payment systems; hospital medical care delivery systems; provider billing and accounting systems; APC groups; Current Procedural Terminology codes; Health Care Common Procedure Coding System (HCPCS) codes; the use of, and payment for, drugs, medical devices, and other services in the outpatient setting...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This standard covers alloy steel nuts for bolting for high-pressure and high-temperature service in nuclear and associated applications. This standard does not cover bar or other starting materials. The only implied special considerations for starting materials are that they be capable of passing the required tests when processed into finished products in accordance with this standard. Material shall conform to the requirements of ASME SA-194; to the requirements of the ASME Boiler and Pressure Vessel Code (ASME Code), Section III, Article NB-2000; to the requirements of NE E 8-18; and to the additional requirements of this standard.
Feasibility of a computer-assisted feedback system between dispatch centre and ambulances.
Lindström, Veronica; Karlsten, Rolf; Falk, Ann-Charlotte; Castrèn, Maaret
2011-06-01
The aim of the study was to evaluate the feasibility of a newly developed computer-assisted feedback system between dispatch centre and ambulances in Stockholm, Sweden. A computer-assisted feedback system based on a Finnish model was designed to fit the Swedish emergency medical system. Feedback codes were identified and divided into three categories; assessment of patients' primary condition when ambulance arrives at scene, no transport by the ambulance and level of priority. Two ambulances and one emergency medical communication centre (EMCC) in Stockholm participated in the study. A sample of 530 feedback codes sent through the computer-assisted feedback system was reviewed. The information on the ambulance medical records was compared with the feedback codes used and 240 assignments were further analyzed. The used feedback codes sent from ambulance to EMCC were correct in 92% of the assignments. The most commonly used feedback code sent to the emergency medical dispatchers was 'agree with the dispatchers' assessment'. In addition, in 160 assignments there was a mismatch between emergency medical dispatchers and ambulance nurse assessments. Our results have shown a high agreement between medical dispatchers and ambulance nurse assessment. The feasibility of the feedback codes seems to be acceptable based on the small margin of error. The computer-assisted feedback system may, when used on a daily basis, make it possible for the medical dispatchers to receive feedback in a structural way. The EMCC organization can directly evaluate any changes in the assessment protocol by structured feedback sent from the ambulance.
Ethics in human experimentation: the two military physicians who helped develop the Nuremberg Code.
Temme, Leonard A
2003-12-01
The Nuremberg Code is generally considered the beginning of modern ethics in human experimentation. The Code is a list of 10 principles that Judge Walter Beals included in the judgment he delivered at the close of the Nuremberg Medical Trial on 19 August 1947. Recently, scholars have studied the origin of the Code, who wrote it, and why. This is important to military medicine and the Aerospace Medical Association in particular because many of the defendants claimed their crimes were experiments in aviation and environmental physiology conducted under wartime conditions. The chief prosecutor of the Nuremberg Medical Trial, General Telford Taylor, relied on the guidance of an advisor provided by the American Medical Association, Andrew C. Ivy, one of the foremost physiologists of his time. The neurologist, Leo Alexander, then a colonel in the U.S. Army Reserves, was another medical advisor. Both men were crucial to the development of Taylor's courtroom strategy. The material Alexander and Ivy provided was incorporated verbatim in the section of the judgment that became the Code. Although both men contributed to the Code, Ivy provided what seems to be the first formulation of many of these principles during a meeting of Allied medical investigators at the Pasteur Institute in July 1946. Naval researchers should note that Ivy had been the Director of the Research Division of the Naval Medical Research Institute when it was commissioned on October 27, 1942.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE REPORTING... preexisting medical conditions. (c) Device information (Form 3500A, Block D). You must submit the following... device code (refer to FDA MEDWATCH Medical Device Reporting Code Instructions); (11) Whether a report was...
Code of Federal Regulations, 2011 CFR
2011-04-01
... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE REPORTING... preexisting medical conditions. (c) Device information (Form 3500A, Block D). You must submit the following... device code (refer to FDA MEDWATCH Medical Device Reporting Code Instructions); (11) Whether a report was...
Liang, Su-Ying; Phillips, Kathryn A.; Wang, Grace; Keohane, Carol; Armstrong, Joanne; Morris, William M.; Haas, Jennifer S.
2012-01-01
Background Administrative claims and medical records are important data sources to examine healthcare utilization and outcomes. Little is known about identifying personalized medicine technologies in these sources. Objectives To describe agreement, sensitivity, and specificity of administrative claims compared to medical records for two pairs of targeted tests and treatments for breast cancer. Research Design Retrospective analysis of medical records linked to administrative claims from a large health plan. We examined whether agreement varied by factors that facilitate tracking in claims (coding and cost) and that enhance medical record completeness (records from multiple providers). Subjects Women (35 – 65 years) with incident breast cancer diagnosed in 2006–2007 (n=775). Measures Use of human epidermal growth factor receptor 2 (HER2) and gene expression profiling (GEP) testing, trastuzumab and adjuvant chemotherapy in claims and medical records. Results Agreement between claims and records was substantial for GEP, trastuzumab, and chemotherapy, and lowest for HER2 tests. GEP, an expensive test with unique billing codes, had higher agreement (91.6% vs. 75.2%), sensitivity (94.9% vs. 76.7%), and specificity (90.1% vs. 29.2%) than HER2, a test without unique billing codes. Trastuzumab, a treatment with unique billing codes, had slightly higher agreement (95.1% vs. 90%) and sensitivity (98.1% vs. 87.9%) than adjuvant chemotherapy. Conclusions Higher agreement and specificity were associated with services that had unique billing codes and high cost. Administrative claims may be sufficient for examining services with unique billing codes. Medical records provide better data for identifying tests lacking specific codes and for research requiring detailed clinical information. PMID:21422962
Siruguri, Vasanthi; Bharatraj, Dinesh Kumar; Vankudavath, Raju Naik; Mendu, Vishnu Vardhana Rao; Gupta, Vibha; Goodman, Richard E
2015-09-01
The potential allergenicity of Bar, Barnase, and Barstar recombinant proteins expressed in genetically engineered mustard for pollination control in plant breeding was evaluated for regulatory review. To evaluate the potential allergenicity of the Bar, Barnase and Barstar proteins amino acid sequence comparisons were made to those of known and putative allergens, and search for published evidence to the sources of the genes using the AllergenOnline.org database. Initial comparisons in 2012 were performed with version 12 by methods recommended by the Codex Alimentarius Commission and the Indian Council of Medical Research, Government of India. Searches were repeated with version 15 in 2015. A literature search was performed using PubMed to identify reports of allergy associated with the sources of the three transgenes. Potential open reading frames at the DNA insertion site were evaluated for matches to allergens. No significant sequence identity matches were identified with Bar, Barnase or Barstar proteins or potential fusion peptides at the genomic-insert junctions compared to known allergens. No references were identified that associated the sources of the genes with allergy. Based on these results we conclude that the Bar, Barnase and Barstar proteins are unlikely to present any significant risk of food allergy to consumers. Copyright © 2015 Elsevier Ltd. All rights reserved.
Towards a European code of medical ethics. Ethical and legal issues.
Patuzzo, Sara; Pulice, Elisabetta
2017-01-01
The feasibility of a common European code of medical ethics is discussed, with consideration and evaluation of the difficulties such a project is going to face, from both the legal and ethical points of view. On the one hand, the analysis will underline the limits of a common European code of medical ethics as an instrument for harmonising national professional rules in the European context; on the other hand, we will highlight some of the potentials of this project, which could be increased and strengthened through a proper rulemaking process and through adequate and careful choice of content. We will also stress specific elements and devices that should be taken into consideration during the establishment of the code, from both procedural and content perspectives. Regarding methodological issues, the limits and potentialities of a common European code of medical ethics will be analysed from an ethical point of view and then from a legal perspective. The aim of this paper is to clarify the framework for the potential but controversial role of the code in the European context, showing the difficulties in enforcing and harmonising national ethical rules into a European code of medical ethics. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
High-power diode laser modules from 410 nm to 2200 nm
NASA Astrophysics Data System (ADS)
Köhler, Bernd; Kissel, Heiko; Flament, Marco; Wolf, Paul; Brand, Thomas; Biesenbach, Jens
2010-02-01
In this work we report on high-power diode laser modules covering a wide spectral range from 410 nm to 2200 nm. Driven by improvements in the technology of diode laser bars with non-standard wavelengths, such systems are finding a growing number of applications. Fields of application that benefit from these developments are direct medical applications, printing industry, defense technology, polymer welding and pumping of solid-sate lasers. Diode laser bars with standard wavelengths from 800 - 1000 nm are based on InGaAlAs, InGaAlP, GaAsP or InGaAs semiconductor material with an optical power of more than 100 W per bar. For shorter wavelengths from 630 - 690 nm InGaAlP semiconductor material is used with an optical power of about 5 W per bar. Extending the wavelength range beyond 1100 nm is realized by using InGaAs on InP substrates or with InAs quantum dots embedded in GaAs for wavelengths up to 1320 nm and (AlGaIn)(AsSb) for wavelengths up to 2200 nm. In these wavelength ranges the output power per bar is about 6 - 20 W. In this paper we present a detailed characterization of these diode laser bars, including measurements of power, spectral data and life time data. In addition, we will show different fiber coupled modules, ranging from 638 nm with 13 W output power (400 μm fiber, NA 0.22) up to 1940 nm with more than 50 W output power (600 μm fiber NA 0.22).
Tendal, Britta; Hróbjartsson, Asbjørn; Lundh, Andreas; Gøtzsche, Peter C
2014-01-01
Objective To assess the effects of coding and coding conventions on summaries and tabulations of adverse events data on suicidality within clinical study reports. Design Systematic electronic search for adverse events of suicidality in tables, narratives, and listings of adverse events in individual patients within clinical study reports. Where possible, for each event we extracted the original term reported by the investigator, the term as coded by the medical coding dictionary, medical coding dictionary used, and the patient’s trial identification number. Using the patient’s trial identification number, we attempted to reconcile data on the same event between the different formats for presenting data on adverse events within the clinical study report. Setting 9 randomised placebo controlled trials of duloxetine for major depressive disorder submitted to the European Medicines Agency for marketing approval. Data sources Clinical study reports obtained from the EMA in 2011. Results Six trials used the medical coding dictionary COSTART (Coding Symbols for a Thesaurus of Adverse Reaction Terms) and three used MedDRA (Medical Dictionary for Regulatory Activities). Suicides were clearly identifiable in all formats of adverse event data in clinical study reports. Suicide attempts presented in tables included both definitive and provisional diagnoses. Suicidal ideation and preparatory behaviour were obscured in some tables owing to the lack of specificity of the medical coding dictionary, especially COSTART. Furthermore, we found one event of suicidal ideation described in narrative text that was absent from tables and adverse event listings of individual patients. The reason for this is unclear, but may be due to the coding conventions used. Conclusion Data on adverse events in tables in clinical study reports may not accurately represent the underlying patient data because of the medical dictionaries and coding conventions used. In clinical study reports, the listings of adverse events for individual patients and narratives of adverse events can provide additional information, including original investigator reported adverse event terms, which can enable a more accurate estimate of harms. PMID:24899651
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-20
... Panel. This expertise encompasses hospital payment systems; hospital medical-care delivery systems; provider billing systems; APC groups, Current Procedural Terminology codes, and alpha-numeric Healthcare Common Procedure Coding System codes; and the use of, and payment for, drugs and medical devices in the...
Singh, Anushikha; Dutta, Malay Kishore; Sharma, Dilip Kumar
2016-10-01
Identification of fundus images during transmission and storage in database for tele-ophthalmology applications is an important issue in modern era. The proposed work presents a novel accurate method for generation of unique identification code for identification of fundus images for tele-ophthalmology applications and storage in databases. Unlike existing methods of steganography and watermarking, this method does not tamper the medical image as nothing is embedded in this approach and there is no loss of medical information. Strategic combination of unique blood vessel pattern and patient ID is considered for generation of unique identification code for the digital fundus images. Segmented blood vessel pattern near the optic disc is strategically combined with patient ID for generation of a unique identification code for the image. The proposed method of medical image identification is tested on the publically available DRIVE and MESSIDOR database of fundus image and results are encouraging. Experimental results indicate the uniqueness of identification code and lossless recovery of patient identity from unique identification code for integrity verification of fundus images. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
The Effect of Manual Restraint on Physiological Parameters in Barred Owls ( Strix varia ).
Doss, Grayson A; Mans, Christoph
2017-03-01
Manual restraint is commonly necessary when working with avian species in medical, laboratory, and field settings. Despite their prevalence, little is known about the stress response in raptorial bird species. To further understand the effect of restraint on the stress response in birds of prey, 12 barred owls ( Strix varia ) were manually restrained for 15 minutes. Physiological parameters (cloacal temperature, respiratory rate, heart rate) were followed over time and recorded at defined points during the restraint period. Heart rate decreased significantly over the restraint period by a mean ± SD of -73 ± 46 beats/min. Respiratory rate also decreased significantly (median: -11 breaths/min, interquartile range: -8 to -18). Cloacal temperature increased significantly over time in manually restrained owls (median: +1.5°C [+2.7°F], interquartile range: 1.3°C-2.1°C [2.3°F-3.8°F]). This study is the first to document stress hyperthermia in an owl species. Similar to another raptorial bird, the red-tailed hawk ( Buteo jamaicensis ), both heart rate and respiratory rate decreased and cloacal temperature increased over time in restrained barred owls. Barred owls appear to cope differently to restraint stress when compared to psittacine species.
Grohmann, Lutz; Brünen-Nieweler, Claudia; Nemeth, Anne; Waiblinger, Hans-Ulrich
2009-10-14
Polymerase Chain Reaction (PCR)-based screening methods targeting genetic elements commonly used in genetically modified (GM) plants are important tools for the detection of GM materials in food, feed, and seed samples. To expand and harmonize the screening capability of enforcement laboratories, the German Federal Office of Consumer Protection and Food Safety conducted collaborative trials for interlaboratory validation of real-time PCR methods for detection of the phosphinothricin acetyltransferase (bar) gene from Streptomyces hygroscopicus and a construct containing the 5-enolpyruvylshikimate-3-phosphate synthase gene from Agrobacterium tumefaciens sp. strain CP4 (ctp2-cp4epsps), respectively. To assess the limit of detection, precision, and accuracy of the methods, laboratories had to analyze two sets of 18 coded genomic DNA samples of events LLRice62 and MS8 with the bar method and NK603 and GT73 with the ctp2-cp4epsps method at analyte levels of 0, 0.02, and 0.1% GM content, respectively. In addition, standard DNAs were provided to the laboratories to generate calibration curves for copy number quantification of the bar and ctp2-cp4epsps target sequences present in the test samples. The study design and the results obtained are discussed with respect to the difficult issue of developing general guidelines and concepts for the collaborative trial validation of qualitative PCR screening methods.
NASA Astrophysics Data System (ADS)
Song, Ning; WANG, Zixiao; LIU, Zhiyong; Zhou, Jiyuan; Zheng, Duo
2017-01-01
The corrosion currents of steel bar in concrete with three W/B and four chloride contents after surface-painting two migrating corrosion inhibitors (PCI-2015 and MCI-A) 14d to 150d in atmospheric condition were measured. The results showed that the corrosion current density (I corr) of steel bar reduced to 0.1 μA.cm-2 from the initial highest 3.833 μA.cm-2 (W/B=0.65, NaCl-1%) after surface-painting PCI-2015 14 d, and the I corr was still lower than 0.1 μA.cm-2 until 150d. The compressive strength and chloride migration coefficient of concrete specimens were tested. The possible reasons of the mechanisms of durability improvement for reinforced concrete by applying PCI-2015 inhibitor were PCI-2015 may be reacted with calcium hydroxide in cement concrete and lots of inhibitor particles may be adsorbed on the active sites first and then a stable protective layer may be formed. The I corr of steel bars in a hydraulic aqueduct concrete structure after painting PCI-2015, MCI-A (the United States) and MCI-B (Europe) during 6 months was monitored by Gecor 8 tester. The results showed that the average values of I corr of steel bars after painting the PCI-2015 150d fulfilled the specification requirements in “Design code for concrete structure strengthening (E.3) ”(GB 50367-2013).
Romley, John A; Cohen, Deborah; Ringel, Jeanne; Sturm, Roland
2007-01-01
This study had two purposes: (1) to characterize the density of liquor stores and bars that individuals face according to race, economic status, and age in the urban United States and (2) to assess alternative measures of retailer density based on the road network and population. We used census data on business counts and sociodemographic characteristics to compute the densities facing individuals in 9,361 urban zip codes. Blacks face higher densities of liquor stores than do whites. The density of liquor stores is greater among nonwhites in lower-income areas than among whites in lower- and higher-income areas and nonwhites in higher-income areas. Nonwhite youths face higher densities of liquor stores than white youths. The density of liquor stores and bars is lower in higher-income areas, especially for nonwhites. Mismatches between alcohol demand and the supply of liquor stores within urban neighborhoods constitute an environmental injustice for minorities and lower-income persons, with potential adverse consequences for drinking behavior and other social ills. Our results for bars are sensitive to the measure of outlet density as well as population density. Although neither measure is clearly superior, a measure that accounts for roadway miles may reflect proximity to alcohol retailers and thus serve as a useful refinement to the per-capita measure. If so, alcohol policy might also focus on density per roadway mile. Further research on the existence, causes, and consequences of environmental injustice in alcohol retailing is warranted.
Moreira, Maria E; Hernandez, Caleb; Stevens, Allen D; Jones, Seth; Sande, Margaret; Blumen, Jason R; Hopkins, Emily; Bakes, Katherine; Haukoos, Jason S
2015-08-01
The Institute of Medicine has called on the US health care system to identify and reduce medical errors. Unfortunately, medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients when dosing requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national health care priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared with conventional medication administration, in simulated pediatric emergency department (ED) resuscitation scenarios. We performed a prospective, block-randomized, crossover study in which 10 emergency physician and nurse teams managed 2 simulated pediatric arrest scenarios in situ, using either prefilled, color-coded syringes (intervention) or conventional drug administration methods (control). The ED resuscitation room and the intravenous medication port were video recorded during the simulations. Data were extracted from video review by blinded, independent reviewers. Median time to delivery of all doses for the conventional and color-coded delivery groups was 47 seconds (95% confidence interval [CI] 40 to 53 seconds) and 19 seconds (95% CI 18 to 20 seconds), respectively (difference=27 seconds; 95% CI 21 to 33 seconds). With the conventional method, 118 doses were administered, with 20 critical dosing errors (17%); with the color-coded method, 123 doses were administered, with 0 critical dosing errors (difference=17%; 95% CI 4% to 30%). A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by emergency physician and nurse teams during simulated pediatric ED resuscitations. Copyright © 2015 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
[Acute Care Rehabilitation is the First Link in a Chain of Rehabilitation Interventions].
Beyer, Joachim; Seidel, Egbert J
2017-08-01
An early, intensive rehabilitative therapy accelerates the recovery of the functions of patients. It contributes to a reduction in the complication rate as well as an improvement in physical and social functioning/participation in the long-term follow-up. Early rehabilitation must be strengthened on the basis of the existing structures: the creation and maintenance of adequately qualified early-stage rehabilitation facilities, at least in hospitals with priority and maximum supply contracts. Patients with long-term intensive care and polytrauma must be rehabilitated as soon as possible (intensive medical rehabilitation).Specialists in physical and rehabilitative medicine, rehabilitative geriatrists, neurologists, orthopaedists and accident surgeons and other regional physicians must cooperate in a targeted manner. Exclusion criteria using corresponding OPS codes must be canceled. Additional specialist physician groups (anesthetists and intensive care physicians, general practitioners, accident and thoracic surgeons, internists) must be sensitized to the importance of early rehabilitation.In the case of more than 500,000 hospital beds, 25,000 beds should be identified as age- and diagnosis-independent early-care beds in the country-specific bed-care plans. A cost-covering financing of the different, personal and cost-intensive early rehabilitation must be ensured. A phase model similar to the BAR guidelines for neurological-neurosurgical early rehabilitation is to be considered for other disease entities.In order to make the rehabilitation process as successful as possible, medical (acute) treatment, medical rehabilitation, occupational integration and social integration have to be understood as a holistic event and are effectively interrelated, as a continuous process which accompanies the entire disease phase-wise. For this purpose, a continuous case management or a rehabilitation guidance has to be established. © Georg Thieme Verlag KG Stuttgart · New York.
TRIAD IV: Nationwide Survey of Medical Students' Understanding of Living Wills and DNR Orders.
Mirarchi, Ferdinando L; Ray, Matthew; Cooney, Timothy
2016-12-01
Living wills are a form of advance directives that help to protect patient autonomy. They are frequently encountered in the conduct of medicine. Because of their impact on care, it is important to understand the adequacy of current medical school training in the preparation of physicians to interpret these directives. Between April and August 2011 of third and fourth year medical students participated in an internet survey involving the interpretation of living wills. The survey presented a standard living will as a "stand-alone," a standard living will with the addition an emergent clinical scenario and then variations of the standard living will that included a code status designation ("DNR," "Full Code," or "Comfort Care"). For each version/ scenario, respondents were asked to assign a code status and choose interventions based on the cases presented. Four hundred twenty-five students from medical schools throughout the country responded. The majority indicated they had received some form of advance directive training and understood the concept of code status and the term "DNR." Based on a stand-alone document, 15% of respondents correctly denoted "full code" as the appropriate code status; adding a clinical scenario yielded negligible improvement. When a code designation was added to the living will, correct code status responses ranged from 68% to 93%, whereas correct treatment decisions ranged from 18% to 78%. Previous training in advance directives had no impact on these results. Our data indicate that the majority of students failed to understand the key elements of a living will; adding a code status designations improved correct responses with the exception of the term DNR. Misunderstanding of advance directives is a nationwide problem and jeopardizes patient safety. Medical School ethics curricula need to be improved to ensure competency with respect to understanding advance directives.
The Unsupervised Acquisition of a Lexicon from Continuous Speech.
1995-11-01
Com- munication, 2(1):57{89, 1982. [42] J. Ziv and A. Lempel . Compression of individual sequences by variable rate coding. IEEE Trans- actions on...parameters of the compression algorithm , in a never-ending attempt to identify and eliminate the predictable. They lead us to a class of grammars in...the rst 10 sentences of the test set, previously unseen by the algorithm . Vertical bars indicate word boundaries. 7.1 Text Compression and Language
Tactical Utility of Tailored Systems
2015-07-10
create a procurement system to produce materiel at a cost low enough to make equipment disposable. Further cost savings may be realized by upgrading...replacement parts. With the advent of 3-d printing and digital manufacturing, a new part may be procured as easily as scanning a bar code and pressing...9/11 Commission Report “Imagination is not a gift usually associated with bureaucracies. It is therefore crucial to find a way of routinizing, even
2017-04-19
At the Kennedy Space Center Visitor Complex, students monitor progress as their Swarmie robots as they search for "resources." The goal is for the robots to pick up cubes with AprilTags, which are similar to bar codes. The Swarmies then move the cubes to a white square in the center of the completion arena. The small, four-wheeled robots are designed to effectively and efficiently locate hidden resources while astronauts explore distant destinations such as the moon or Mars.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1978-12-04
The following appendices are included; Dynamic Simulation Program (ODSP-3); sample results of dynamic simulation; trip report - NH/sub 3/ safety precautions/accident records; trip report - US Coast Guard Headquarters; OTEC power system development, preliminary design test program report; medium turbine generator inspection point program; net energy analysis; bus bar cost of electricity; OTEC technical specifications; and engineer drawings. (WHK)
DNA Repair and Ethnic Differences in Prostate Cancer Risk
2006-03-01
Georgetown University for processing . Each sample is centrifuged and the blood components are separated into serum, clot, buffy coat, and plasma...within 4 hours of reception. The processed , aliquoted, and bar-coded samples are stored in a repository at GUH at -80oC. The slow growth of prostate...completeness. Daily backups are performed to protect data against accidental destruction or corruption. Blood samples are processed within 24 hours of sample
Integrating advanced practice providers into medical critical care teams.
McCarthy, Christine; O'Rourke, Nancy C; Madison, J Mark
2013-03-01
Because there is increasing demand for critical care providers in the United States, many medical ICUs for adults have begun to integrate nurse practitioners and physician assistants into their medical teams. Studies suggest that such advanced practice providers (APPs), when appropriately trained in acute care, can be highly effective in helping to deliver high-quality medical critical care and can be important elements of teams with multiple providers, including those with medical house staff. One aspect of building an integrated team is a practice model that features appropriate coding and billing of services by all providers. Therefore, it is important to understand an APP's scope of practice, when they are qualified for reimbursement, and how they may appropriately coordinate coding and billing with other team providers. In particular, understanding when and how to appropriately code for critical care services (Current Procedural Terminology [CPT] code 99291, critical care, evaluation and management of the critically ill or critically injured patient, first 30-74 min; CPT code 99292, critical care, each additional 30 min) and procedures is vital for creating a sustainable program. Because APPs will likely play a growing role in medical critical care units in the future, more studies are needed to compare different practice models and to determine the best way to deploy this talent in specific ICU settings.
Investigating the Use of Quick Response Codes in the Gross Anatomy Laboratory
ERIC Educational Resources Information Center
Traser, Courtney J.; Hoffman, Leslie A.; Seifert, Mark F.; Wilson, Adam B.
2015-01-01
The use of quick response (QR) codes within undergraduate university courses is on the rise, yet literature concerning their use in medical education is scant. This study examined student perceptions on the usefulness of QR codes as learning aids in a medical gross anatomy course, statistically analyzed whether this learning aid impacted student…
Stevens, Allen D.; Hernandez, Caleb; Jones, Seth; Moreira, Maria E.; Blumen, Jason R.; Hopkins, Emily; Sande, Margaret; Bakes, Katherine; Haukoos, Jason S.
2016-01-01
Background Medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients where dosing often requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national healthcare priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared to conventional medication administration, in simulated prehospital pediatric resuscitation scenarios. Methods We performed a prospective, block-randomized, cross-over study, where 10 full-time paramedics each managed two simulated pediatric arrests in situ using either prefilled, color-coded-syringes (intervention) or their own medication kits stocked with conventional ampoules (control). Each paramedic was paired with two emergency medical technicians to provide ventilations and compressions as directed. The ambulance patient compartment and the intravenous medication port were video recorded. Data were extracted from video review by blinded, independent reviewers. Results Median time to delivery of all doses for the intervention and control groups was 34 (95% CI: 28–39) seconds and 42 (95% CI: 36–51) seconds, respectively (difference = 9 [95% CI: 4–14] seconds). Using the conventional method, 62 doses were administered with 24 (39%) critical dosing errors; using the prefilled, color-coded syringe method, 59 doses were administered with 0 (0%) critical dosing errors (difference = 39%, 95% CI: 13–61%). Conclusions A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by paramedics during simulated prehospital pediatric resuscitations. PMID:26247145
Stevens, Allen D; Hernandez, Caleb; Jones, Seth; Moreira, Maria E; Blumen, Jason R; Hopkins, Emily; Sande, Margaret; Bakes, Katherine; Haukoos, Jason S
2015-11-01
Medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients where dosing often requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national healthcare priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared to conventional medication administration, in simulated prehospital pediatric resuscitation scenarios. We performed a prospective, block-randomized, cross-over study, where 10 full-time paramedics each managed two simulated pediatric arrests in situ using either prefilled, color-coded syringes (intervention) or their own medication kits stocked with conventional ampoules (control). Each paramedic was paired with two emergency medical technicians to provide ventilations and compressions as directed. The ambulance patient compartment and the intravenous medication port were video recorded. Data were extracted from video review by blinded, independent reviewers. Median time to delivery of all doses for the intervention and control groups was 34 (95% CI: 28-39) seconds and 42 (95% CI: 36-51) seconds, respectively (difference=9 [95% CI: 4-14] seconds). Using the conventional method, 62 doses were administered with 24 (39%) critical dosing errors; using the prefilled, color-coded syringe method, 59 doses were administered with 0 (0%) critical dosing errors (difference=39%, 95% CI: 13-61%). A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by paramedics during simulated prehospital pediatric resuscitations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Weindling, P
2001-01-01
The Nuremberg Code has generally been seen as arising from the Nuremberg Medical Trial. This paper examines developments prior to the Trial, involving the physiologist Andrew Conway Ivy and an inter-Allied Scientific Commission on Medical War Crimes. The paper traces the formulation of the concept of a medical war crime by the physiologist John West Thompson, as part of the background to Ivy's code on human experiments of 1 August 1946. It evaluates subsequent responses by the American Medical Association, and by other war crimes experts, notably Leo Alexander, who developed Ivy's conceptual framework. Ivy's interaction with the judges at Nuremberg alerted them to the importance of formulating ethical guidelines for clinical research.
Progress in Search for Antihelium with BESS
NASA Technical Reports Server (NTRS)
Sasaki, M.; Matsumoto, H.; Nozaki, M.; Saeki, T.; Abe, K.; Anraku, K.; Asoka, Y.; Fujikawa, M.; Fuke, H.; Imori, M.
2002-01-01
We have searched for antihelium nuclei in cosmic rays using the data obtained from balloon flights of the BESS magnetic spectrometer. The search was mainly based on track-quality selection, followed by rigidity analysis, and on the time-of-flight and dE/dx measurements by the scintillation counter hodoscope. We analysed all the data collected during 1993-2000 with a common analysis procedure. No antihelium nuclei events were found in the energy range from 1 to 14 GV. In order to determine a new upper limit, we have simulated the loss in the air and in the instrument of He (He-bar) using the GEANT/GHEISHA code. Combined with the data collected in 1993 through 2000, a new 95 % confidence upper limit for the ratio of He-bar/He at the top of the atmosphere of 6.8 x 10(exp -7) has been obtained to be after correcting for the interactions in the air and in the instruments.
Performance scores and standings during the 43rd Artistic Gymnastics World Championships, 2011.
Massidda, Myosotis; Calò, Carla M
2012-01-01
Scores in artistic gymnastics are subject to changes in the rules that occur each Olympic cycle as outlined in the Code of Points, because rules influence the composition of routines and therefore performance. The aim of this study was to identify the most important routine apparatus for success in a World competition. The data were the official results for the 478 gymnasts (262 men, 216 women) who competed in the 43rd Artistic Gymnastic World Championships in 2011 in Tokyo, Japan. The factors least influenced by the technical standard of competitors were performance scores on uneven bars and balance beam for women, and those on pommel horse for men. For uneven bars, balance beam, and pommel horse, scores were consistently good predictors of final standing. Our results suggest that high scores on these apparatus have a greater influence on overall performance than scores on the other apparatus, regardless of the competitors' standard.
Sajjad, Muhammad; Mehmood, Irfan; Baik, Sung Wook
2017-01-01
Medical image collections contain a wealth of information which can assist radiologists and medical experts in diagnosis and disease detection for making well-informed decisions. However, this objective can only be realized if efficient access is provided to semantically relevant cases from the ever-growing medical image repositories. In this paper, we present an efficient method for representing medical images by incorporating visual saliency and deep features obtained from a fine-tuned convolutional neural network (CNN) pre-trained on natural images. Saliency detector is employed to automatically identify regions of interest like tumors, fractures, and calcified spots in images prior to feature extraction. Neuronal activation features termed as neural codes from different CNN layers are comprehensively studied to identify most appropriate features for representing radiographs. This study revealed that neural codes from the last fully connected layer of the fine-tuned CNN are found to be the most suitable for representing medical images. The neural codes extracted from the entire image and salient part of the image are fused to obtain the saliency-injected neural codes (SiNC) descriptor which is used for indexing and retrieval. Finally, locality sensitive hashing techniques are applied on the SiNC descriptor to acquire short binary codes for allowing efficient retrieval in large scale image collections. Comprehensive experimental evaluations on the radiology images dataset reveal that the proposed framework achieves high retrieval accuracy and efficiency for scalable image retrieval applications and compares favorably with existing approaches. PMID:28771497
Are Military and Medical Ethics Necessarily Incompatible? A Canadian Case Study.
Rochon, Christiane; Williams-Jones, Bryn
2016-12-01
Military physicians are often perceived to be in a position of 'dual loyalty' because they have responsibilities towards their patients but also towards their employer, the military institution. Further, they have to ascribe to and are bound by two distinct codes of ethics (i.e., medical and military), each with its own set of values and duties, that could at first glance be considered to be very different or even incompatible. How, then, can military physicians reconcile these two codes of ethics and their distinct professional/institutional values, and assume their responsibilities towards both their patients and the military institution? To clarify this situation, and to show how such a reconciliation might be possible, we compared the history and content of two national professional codes of ethics: the Defence Ethics of the Canadian Armed Forces and the Code of Ethics of the Canadian Medical Association. Interestingly, even if the medical code is more focused on duties and responsibility while the military code is more focused on core values and is supported by a comprehensive ethical training program, they also have many elements in common. Further, both are based on the same core values of loyalty and integrity, and they are broad in scope but are relatively flexible in application. While there are still important sources of tension between and limits within these two codes of ethics, there are fewer differences than may appear at first glance because the core values and principles of military and medical ethics are not so different.
NASA Astrophysics Data System (ADS)
Gutierrez, Marco A.; Cestari, Idagene A.; Hamamoto, Gina; Bacht, Simão; Rebelo, Marina S.; Silva, João E. M. M.; Lage, Silvia G.
2008-03-01
The current study describes the experience in the implementation of a mobile HIS/PACS workstation to assist critical cardiac patients in an Intensive Care Unit (ICU). Recently, mobile devices connected to a WiFi network were incorporated to the Hospital information System, providing the same functionalities of common desktop counterpart. However, the use of commercially devices like PDAs and Pocket PCs presented a series of problems that are more emphasized in the ICUs 1) low autonomy of the batteries, which need constant recharges; 2) low robustness of the devices; 3) insufficient display area to show medical images and vital signals; 4) data entry remains a major problem and imposes an extra time consumption to the staff; 5) high cost when fully equipped with WiFi connection, optical reader to access bar codes and memory. To address theses problems we developed a mobile workstation (MedKart) that provides access the HIS and PACS systems, with all resources and an ergonomic and practical design to be used by physicians and nurses inside the ICU. The system fulfills the requirements to assist, in the point-of-care, critical cardiac patients in Intensive Care Units.
Drug product distribution systems and departmental operations.
Hynniman, C E
1991-10-01
Technologies affecting institutional pharmacy practice and the operation of pharmacy departments are reviewed, future developments are outlined, and implications of these developments for pharmacy education are proposed. Computer technology, especially as applied to areas such as artificial intelligence, online information databases, electronic bulletin boards, hospital information systems, and point-of-care systems, will have a strong impact on pharmacy practice and management in the 1990s. Other areas in which growth is likely to be active include bar-code technology, robotics, and automated drug dispensing. The applications of these technologies are described, with particular attention placed on the effects of increased automation on the drug-dispensing function. Technological advances may effect marked reductions in dispensing and medication errors; questions concerning the cost-effectiveness of these new systems remain to be answered. These advances also create new opportunities for clinical involvement by pharmacists; however, a fundamental understanding of computer systems is essential. Current practitioners can benefit from attending seminars, participating in users' groups, and keeping current with the computer literature. Many students now acquire the needed skills in computer laboratories and in the classroom. Technological advances will offer the opportunity for pharmacists to expand their clinical role.
Compressed Air Working in Chennai During Metro Tunnel Construction: Occupational Health Problems.
Kulkarni, Ajit C
2017-01-01
Chennai metropolis has been growing rapidly. Need was felt of a metro rail system. Two corridors were planned. Corridor 1, of 23 km starting from Washermanpet to Airport. 14.3 km of this would be underground. Corridor 2, of 22 km starting from Chennai Central Railway station to St. Thomas Mount. 9.7 km of this would be underground. Occupational health centre's role involved selection of miners and assessing their fitness to work under compressed air. Planning and execution of compression and decompression, health monitoring and treatment of compression related illnesses. More than thirty five thousand man hours of work was carried out under compressed air pressure ranged from 1.2 to 1.9 bar absolute. There were only three cases of pain only ( Type I) decompression sickness which were treated with recompression. Vigilant medical supervision, experienced lock operators and reduced working hours under pressure because of inclement environmental conditions viz. high temperature and humidity, has helped achieve this low incident. Tunnelling activity will increase in India as more cities will soon opt for underground metro railway. Indian standard IS 4138 - 1977 " Safety code for working in compressed air" needs to be updated urgently keeping pace with modern working methods.
Code of Federal Regulations, 2011 CFR
2011-04-01
... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE REPORTING..., result, and conclusion codes) (refer to FDA MEDWATCH Medical Device Reporting Code Instructions); (7... the device was involved, nature of the problem, patient followup or required treatment, and any...
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE REPORTING..., result, and conclusion codes) (refer to FDA MEDWATCH Medical Device Reporting Code Instructions); (7... the device was involved, nature of the problem, patient followup or required treatment, and any...
Coutinho Moraes, Denise F; Still, David W; Lum, Michelle R; Hirsch, Ann M
2015-06-01
Herbal medicines and botanicals have long been used as sole or additional medical aids worldwide. Currently, billions of dollars are spent on botanicals and related products, but minimal regulation exists regarding their purity, integrity, and efficacy. Cases of adulteration and contamination have led to severe illness and even death in some cases. Identifying the plant material in botanicals and phytomedicines using organoleptic means or through microscopic observation of plant parts is not trivial, and plants are often misidentified. Recently, DNA-based methods have been applied to these products because DNA is not changed by growth conditions unlike the chemical constituents of many active pharmaceutical agents. In recent years, DNA barcoding methods, which are used to identify species diversity in the Tree of Life, have been also applied to botanicals and plant-derived dietary supplements. In this review, we recount the history of DNA-based methods for identification of botanicals and discuss some of the difficulties in defining a specific bar code or codes to use. In addition, we describe how next generation sequencing technologies have enabled new techniques that can be applied to identifying these products with greater authority and resolution. Lastly, we present case histories where dietary supplements, decoctions, and other products have been shown to contain materials other than the main ingredient stipulated on the label. We conclude that there is a fundamental need for greater quality control in this industry, which if not self-imposed, that may result from legislation. Georg Thieme Verlag KG Stuttgart · New York.
Canham-Chervak, Michelle; Steelman, Ryan A; Schuh, Anna; Jones, Bruce H
2016-11-01
Injuries are a barrier to military medical readiness, and overexertion has historically been a leading mechanism of injury among active duty U.S. Army soldiers. Details are needed to inform prevention planning. The Defense Medical Surveillance System (DMSS) was queried for unique medical encounters among active duty Army soldiers consistent with the military injury definition and assigned an overexertion external cause code (ICD-9: E927.0-E927.9) in 2014 (n=21,891). Most (99.7%) were outpatient visits and 60% were attributed specifically to sudden strenuous movement. Among the 41% (n=9,061) of visits with an activity code (ICD-9: E001-E030), running was the most common activity (n=2,891, 32%); among the 19% (n=4,190) with a place of occurrence code (ICD-9: E849.0-E849.9), the leading location was recreation/sports facilities (n=1,332, 32%). External cause codes provide essential details, but the data represented less than 4% of all injury-related medical encounters among U.S. Army soldiers in 2014. Efforts to improve external cause coding are needed, and could be aligned with training on and enforcement of ICD-10 coding guidelines throughout the Military Health System.
Reducing Toxicity of Radiation Treatment of Advanced Prostate Cancer
2013-10-01
frequency of apoptotic cells. Red – TUNEL positive apoptotic cells, Blue – DAPI nuclear counterstaining. Scale Bar – 100 µm. Quantitation of apoptosis...in the context of the CMCR (Center of Countermeasures against Radiation; NIH NIAID) at Einstein Medical Center, Bronx , NY (PI: Dr. C. Guha
Lowe, Jeanne R; Raugi, Gregory J; Reiber, Gayle E; Whitney, Joanne D
2013-01-01
The purpose of this cohort study was to evaluate the effect of a 1-year intervention of an electronic medical record wound care template on the completeness of wound care documentation and medical coding compared to a similar time interval for the fiscal year preceding the intervention. From October 1, 2006, to September 30, 2007, a "good wound care" intervention was implemented at a rural Veterans Affairs facility to prevent amputations in veterans with diabetes and foot ulcers. The study protocol included a template with foot ulcer variables embedded in the electronic medical record to facilitate data collection, support clinical decision making, and improve ordering and medical coding. The intervention group showed significant differences in complete documentation of good wound care compared to the historic control group (χ = 15.99, P < .001), complete documentation of coding for diagnoses and procedures (χ = 30.23, P < .001), and complete documentation of both good wound care and coding for diagnoses and procedures (χ = 14.96, P < .001). An electronic wound care template improved documentation of evidence-based interventions and facilitated coding for wound complexity and procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Messner, Mark C.; Sham, Sam; Wang, Yanli
This report summarizes the experiments performed in FY17 on Gr. 91 steels. The testing of Gr. 91 has technical significance because, currently, it is the only approved material for Class A construction that is strongly cyclic softening. Specific FY17 testing includes the following activities for Gr. 91 steel. First, two types of key feature testing have been initiated, including two-bar thermal ratcheting and Simplified Model Testing (SMT). The goal is to qualify the Elastic – Perfectly Plastic (EPP) design methodologies and to support incorporation of these rules for Gr. 91 into the ASME Division 5 Code. The preliminary SMT testmore » results show that Gr. 91 is most damaging when tested with compression hold mode under the SMT creep fatigue testing condition. Two-bar thermal ratcheting test results at a temperature range between 350 to 650o C were compared with the EPP strain limits code case evaluation, and the results show that the EPP strain limits code case is conservative. The material information obtained from these key feature tests can also be used to verify its material model. Second, to provide experimental data in support of the viscoplastic material model development at Argonne National Laboratory, selective tests were performed to evaluate the effect of cyclic softening on strain rate sensitivity and creep rates. The results show the prior cyclic loading history decreases the strain rate sensitivity and increases creep rates. In addition, isothermal cyclic stress-strain curves were generated at six different temperatures, and a nonisothermal thermomechanical testing was also performed to provide data to calibrate the viscoplastic material model.« less
Real-Time Pattern Recognition - An Industrial Example
NASA Astrophysics Data System (ADS)
Fitton, Gary M.
1981-11-01
Rapid advancements in cost effective sensors and micro computers are now making practical the on-line implementation of pattern recognition based systems for a variety of industrial applications requiring high processing speeds. One major application area for real time pattern recognition is in the sorting of packaged/cartoned goods at high speed for automated warehousing and return goods cataloging. While there are many OCR and bar code readers available to perform these functions, it is often impractical to use such codes (package too small, adverse esthetics, poor print quality) and an approach which recognizes an item by its graphic content alone is desirable. This paper describes a specific application within the tobacco industry, that of sorting returned cigarette goods by brand and size.
Polarization of Cosmic Microwave Background
NASA Astrophysics Data System (ADS)
Buzzelli, A.; Cabella, P.; de Gasperis, G.; Vittorio, N.
2016-02-01
In this work we present an extension of the ROMA map-making code for data analysis of Cosmic Microwave Background polarization, with particular attention given to the inflationary polarization B-modes. The new algorithm takes into account a possible cross- correlated noise component among the different detectors of a CMB experiment. We tested the code on the observational data of the BOOMERanG (2003) experiment and we show that we are provided with a better estimate of the power spectra, in particular the error bars of the BB spectrum are smaller up to 20% for low multipoles. We point out the general validity of the new method. A possible future application is the LSPE balloon experiment, devoted to the observation of polarization at large angular scales.
Bismark, Marie; Paterson, Ron
2006-01-01
In 1974 New Zealand jettisoned a tort-based system for compensating medical injuries in favor of a government-funded compensation system. Although the system retained some residual fault elements, it essentially barred medical malpractice litigation. Reforms in 2005 expanded eligibility for compensation to all "treatment injuries," creating a true no-fault compensation system. Compared with a medical malpractice system, the New Zealand system offers more-timely compensation to a greater number of injured patients and more-effective processes for complaint resolution and provider accountability. The unfinished business lies in realizing its full potential for improving patient safety.
Health and efficiency in trimix versus air breathing in compressed air workers.
Van Rees Vellinga, T P; Verhoeven, A C; Van Dijk, F J H; Sterk, W
2006-01-01
The Western Scheldt Tunneling Project in the Netherlands provided a unique opportunity to evaluate the effects of trimix usage on the health of compressed air workers and the efficiency of the project. Data analysis addressed 318 exposures to compressed air at 3.9-4.4 bar gauge and 52 exposures to trimix (25% oxygen, 25% helium, and 50% nitrogen) at 4.6-4.8 bar gauge. Results revealed three incidents of decompression sickness all of which involved the use of compressed air. During exposure to compressed air, the effects of nitrogen narcosis were manifested in operational errors and increased fatigue among the workers. When using trimix, less effort was required for breathing, and mandatory decompression times for stays of a specific duration and maximum depth were considerably shorter. We conclude that it might be rational--for both medical and operational reasons--to use breathing gases with lower nitrogen fractions (e.g., trimix) for deep-caisson work at pressures exceeding 3 bar gauge, although definitive studies are needed.
Vial, Andrea C.; Starks, Tyrel J.; Parsons, Jeffrey T.
2015-01-01
Efforts to reach HIV-positive men who have sex with men (MSM) and link them to care must be expanded; however, finding and recruiting them remains a challenge. We compared the efficiency of three recruitment sources in reaching self-identified HIV-positive MSM with various characteristics. Relative to recruitment online and at clubs and bars, AIDS Service Organizations (ASOs) were significantly more efficient in reaching HIV-positive MSM in general. This was also true for those with specific characteristics of interest such as substance/stimulant use, and HIV-positive MSM who were racial/ethnic minorities. Both ASOs and online recruitment were more efficient than clubs and bars in reaching HIV-positive MSM not taking HIV medication. This was also the case for White HIV-positive MSM in general, and White HIV-positive MSM who used substances and stimulants. Online recruitment was also more efficient than clubs and bars in reaching HIV-positive MSM who were young across the board. PMID:25915696
Vial, Andrea C; Starks, Tyrel J; Parsons, Jeffrey T
2015-04-01
Efforts to reach HIV-positive men who have sex with men (MSM) and link them to care must be expanded; however, finding and recruiting them remains a challenge. We compared the efficiency of three recruitment sources in reaching self-identified HIV-positive MSM with various characteristics. Relative to recruitment online and at clubs and bars, AIDS Service Organizations (ASOs) were significantly more efficient in reaching HIV-positive MSM in general. This was also true for those with specific characteristics of interest such as substance/stimulant use, and HIV-positive MSM who were racial/ethnic minorities. Both ASOs and online recruitment were more efficient than clubs and bars in reaching HIV-positive MSM not taking HIV medication. This was also the case for White HIV-positive MSM in general, and White HIV-positive MSM who used substances and stimulants. Online recruitment was also more efficient than clubs and bars in reaching HIV-positive MSM who were young across the board.
The Nuremberg Code: its history and implications.
Kious, B M
2001-01-01
The Nuremberg Code is a foundational document in the ethics of medical research and human experimentation; the principle its authors espoused in 1946 have provided the framework for modern codes that address the same issues, and have received little challenge and only slight modification in decades since. By analyzing the Code's tragic genesis and its normative implications, it is possible to understand some of the essence of modern experimental ethics, as well as certain outstanding controversies that still plague medical science.
Code of Federal Regulations, 2011 CFR
2011-04-01
... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE REPORTING User... device; (10) Event problem codes—patient code and device code (refer to the “MEDWATCH Medical Device... device was involved, nature of the problem, patient followup or required treatment, and any environmental...
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE REPORTING User... device; (10) Event problem codes—patient code and device code (refer to the “MEDWATCH Medical Device... device was involved, nature of the problem, patient followup or required treatment, and any environmental...
Hoffman, Veena; Everage, Nicholas J; Quinlan, Scott C; Skerry, Kathleen; Esposito, Daina; Praet, Nicolas; Rosillon, Dominique; Holick, Crystal N; Dore, David D
2016-12-01
We validated procedure codes used in health insurance claims for reimbursement of rotavirus vaccination by comparing claims for monovalent live-attenuated human rotavirus vaccine (RV1) and live, oral pentavalent rotavirus vaccine (RV5) to medical records. Using administrative data from two commercially insured United States populations, we randomly sampled vaccination claims for RV1 and RV5 from a cohort of infants aged less than 1 year from an ongoing post-licensure safety study of rotavirus vaccines. The codes for RV1 and RV5 found in claims were confirmed through medical record review. The positive predictive value (PPV) of the Current Procedural Terminology codes for RV1 and RV5 was calculated as the number of medical record-confirmed vaccinations divided by the number of medical records obtained. Medical record review confirmed 92 of 104 RV1 vaccination claims (PPV: 88.5%; 95% CI: 80.7-93.9%) and 98 of 113 RV5 vaccination claims (PPV: 86.7%; 95% CI: 79.1-92.4%). Among the 217 medical records abstracted, only three (1.4%) of vaccinations were misclassified in claims-all were RV5 misclassified as RV1. The medical records corresponding to 9 RV1 and 15 RV5 claims contained insufficient information to classify the type of rotavirus vaccine. Misclassification of rotavirus vaccines is infrequent within claims. The PPVs reported here are conservative estimates as those with insufficient information in the medical records were assumed to be incorrectly coded in the claims. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
1980-01-01
NASA developed personal security system, commercialized by Sentry Products, Inc. enables resident to summon instant help in case of medical emergency or threatened violence. Its principal elements are a pen-shaped signaling device, "silent" because its ultrasonic alert signal is inaudible to the human ear, and a system of receivers interconnected with a constantly-monitored aster console. SCAN pen weighs only two ounces and is worn on necklace or attached by a clip to the user's clothing. The person in trouble simply presses a clasp, releasing a hammer inside the pen which strikes an aluminum bar. The impact causes the bar to resonate like a tuning fork and emit the ultrasonic signal, which is detected by the nearest receiver.
Novel packaging for CW and QCW diode laser modules for operation with high power and duty cycles
NASA Astrophysics Data System (ADS)
Fassbender, Wilhelm; Lotz, Jens; Kissel, Heiko; Biesenbach, Jens
2018-02-01
Continuous wave (CW) and quasi-continuous wave (QCW) operated diode laser bars and arrays have found a wide range of industrial, medical, scientific, military and space applications with a broad variety in wavelength, pulse energy, pulse duration and beam quality. Recent applications require even higher power, duty cycles and power density. The heat loss will be dissipated by conductive cooling or liquid cooling close to the bars. We present the latest performance and reliability data of two novel high-brightness CW and QCW arrays of customized and mass-production modules, in compact and robust industry design for operation with high power and high duty cycles. All designs are based on single diode packages consisting of 10mm laser bars, soft or hard soldered between expansion matched submounts. The modular components cover a wide span of designs which differ basically in water/conduction (active/passive) cooled, single, linear (horizontal and vertical) arranged designs, as well as housed and unhoused modules. The different assembling technologies of active and passive cooled base plates affect the heat dissipation and therefore the reachable power at different QCW operating conditions, as well as the lifetime. As an example, a package consisting of 8 laser diodes, connected to a 28.8*13.5*7.0mm3 DCB (direct copper bonded) submount, passively or actively cooled is considered. This design is of particular interest for mobile applications seamless module to module building system, with an infinite number of laser bars at 1.7mm pitch. Using 940nm bars we can reach an optical output power per bar of 450W at 25°C base plate temperature with 10Hz, 1.2% duty cycle and 1.2ms pulse duration. As an additional example, micro channel coolers can be vertically stacked up to 50 diodes with a 1,15mm pitch. This design is suitable for all applications, demanding also compactness and light weight and high power density. Using near infrared bars and others, we can reach an optical output power of 250W per bar at 25°C coolant temperature at CW operation.
Benign Breast Disease: Toward Molecular Prediction of Breast Cancer Risk
2004-06-01
stored in groups according to immunostain (i.e., all of the number 3 slides together, the number 4 slides, and so on) to match the stain in bar coded...standoff between the DOD and Wayne State on consent form language around institutional coverage for any "research- related risks". Dr. Beitens from the...Sponsoring this Study Clinic will not be jeopardized. This work has been, and continues to be, sponsored by several groups including the Confidentiality
Advanced Mail Systems Scanner Technology. Executive Summary and Appendixes A-E.
1980-10-01
data base. 6. Perform color acquisition studies. 7. Investigate address and bar code reading. MASS MEMORY TECHNOLOGY 1. Collect performance data on...area of the 1728-by-2200 ICAS image memory and to transmit the data to any of the three color memories of the Comtal. Function table information can...for printing color images. The software allows the transmission of data from the ICAS frame-store memory via the MCU to the Dicomed. Software test
Underlying Technologies for Military Logistics Prediction and Preemption Capability
2009-02-01
house and a collection of facts is not necessarily science. ” - Henri Poincare 2.1 Overview The data, information, and knowledge that are...1024 bits, so about half of the label on the jar would have been taken up by the bar codes to explain all of this. As chapters 4 and 5 will explain...should be obtainable with reasonable design. This is not as dangerous as the gamma rays produced from other radioactive materials. Half -life of
Design Producibility Assessment System
1989-06-30
Data Base Material Code 17 - 4PH Manufactu Description Precipitation-Handling, corrosion-resist steel Strategic? No Strip Sheet Bar Wire Tube Yes Yes Yes...planned production quantity: 10000 PRODUCTION FACILITIES 5 Select the design material: 17 - 4PH <PgUp> Page Up, <PgDn> Page Down, <Fl> Help, <Esc> Exit DPAS...vl.00 Saturday June 17 , 1989 11:06 am Design Producibility Assessment System Select the design material: 17 - 4PH Select the design material’s form
Martínez, Luary C; Yakhnin, Helen; Camacho, Martha I; Georgellis, Dimitris; Babitzke, Paul; Puente, José L; Bustamante, Víctor H
2011-06-01
Salmonella pathogenicity islands 1 and 2 (SPI-1 and SPI-2) play key roles in the pathogenesis of Salmonella enterica. Previously, we showed that when Salmonella grows in Luria-Bertani medium, HilD, encoded in SPI-1, first induces the expression of hilA, located in SPI-1, and subsequently of the ssrAB operon, located in SPI-2. These genes code for HilA and the SsrA/B two-component system, the positive regulators of the SPI-1 and SPI-2 regulons respectively. In this study, we demonstrate that CsrA, a global regulatory RNA binding protein, post-transcriptionally regulates hilD expression by directly binding near the Shine-Dalgarno and translation initiation codon sequences of the hilD mRNA, preventing its translation and leading to its accelerated turnover. Negative regulation is counteracted by the global SirA/BarA two-component system, which directly activates the expression of CsrB and CsrC, two non-coding regulatory RNAs that sequester CsrA, thereby preventing it from binding to its target mRNAs. Our results illustrate the integration of global and specific regulators into a multifactorial regulatory cascade controlling the expression of virulence genes acquired by horizontal transfer events. © 2011 Blackwell Publishing Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeVolpi, A.; Palm, R.
CFE poses a number of verification challenges that could be met in part by an accurate and low-cost means of aiding in accountability of treaty-limited equipment. Although the treaty as signed does not explicitly call for the use of tags, there is a provision for recording serial numbers'' and placing special marks'' on equipment subject to reduction. There are approximately 150,000 residual items to be tracked for CFE-I, about half for each alliance of state parties. These highly mobile items are subject to complex treaty limitations: deployment limits and zones, ceilings subceilings, holdings and allowances. There are controls and requirementsmore » for storage, conversion, and reduction. In addition, there are national security concerns regarding modernization and mobilization capability. As written into the treaty, a heavy reliance has been placed on human inspectors for CFE verification. Inspectors will mostly make visual observations and photographs as the means of monitoring compliance; these observations can be recorded by handwriting or keyed into a laptop computer. CFE is now less a treaty between two alliances than a treaty among 22 state parties, with inspection data an reports to be shared with each party in the official languages designated by CSCE. One of the potential roles for bar-coded tags would be to provide a universal, exchangable, computer-compatible language for tracking TLE. 10 figs.« less
Electronic tagging and integrated product intelligence
NASA Astrophysics Data System (ADS)
Swerdlow, Martin; Weeks, Brian
1996-03-01
The advent of 'intelligent,' electronic data bearing tags is set to revolutionize the way industrial and retail products are identified and tracked throughout their life cycles. The dominant system for unique identification today is the bar code, which is based on printed symbology and regulated by the International Article Numbering Association. Bar codes provide users with significant operational advantages and generate considerable added value to packaging companies, product manufacturers, distributors and retailers, across supply chains in many different sectors, from retailing, to baggage handling and industrial components, e.g., for vehicles or aircraft. Electronic tags offer the potential to: (1) record and store more complex data about the product or any modifications which occur during its life cycle; (2) access (and up-date) stored data in real time in a way which does not involve contact with the product or article; (3) overcome the limitations imposed by systems which rely on line-of-sight access to stored data. Companies are now beginning to consider how electronic data tags can be used, not only to improve the efficiency of their supply chain processes, but also to revolutionize the way they do business. This paper reviews the applications and business opportunities for electronic tags and outlines CEST's strategy for achieving an 'open' standard which will ensure that tags from different vendors can co-exist on an international basis.
Neu, Thomas R; Kuhlicke, Ute
2017-02-10
Microbial biofilm systems are defined as interface-associated microorganisms embedded into a self-produced matrix. The extracellular matrix represents a continuous challenge in terms of characterization and analysis. The tools applied in more detailed studies comprise extraction/chemical analysis, molecular characterization, and visualisation using various techniques. Imaging by laser microscopy became a standard tool for biofilm analysis, and, in combination with fluorescently labelled lectins, the glycoconjugates of the matrix can be assessed. By employing this approach a wide range of pure culture biofilms from different habitats were examined using the commercially available lectins. From the results, a binary barcode pattern of lectin binding can be generated. Furthermore, the results can be fine-tuned and transferred into a heat map according to signal intensity. The lectin barcode approach is suggested as a useful tool for investigating the biofilm matrix characteristics and dynamics at various levels, e.g. bacterial cell surfaces, adhesive footprints, individual microcolonies, and the gross biofilm or bio-aggregate. Hence fluorescence lectin bar-coding (FLBC) serves as a basis for a subsequent tailor-made fluorescence lectin-binding analysis (FLBA) of a particular biofilm. So far, the lectin approach represents the only tool for in situ characterization of the glycoconjugate makeup in biofilm systems. Furthermore, lectin staining lends itself to other fluorescence techniques in order to correlate it with cellular biofilm constituents in general and glycoconjugate producers in particular.
Aerothermal Assment Of The Expert Flap In The SCIROCCO Wind Tunnel
NASA Astrophysics Data System (ADS)
Walpot, L.; Di Clemente, M.; Vos, J.; Etchells, J.; Trifoni, E.; Thoemel, J.; Gavira, J.
2011-05-01
In the frame of the “In-Flight Test Measurement Techniques for Aerothermodynamics” activity of the EXPERT Program, the EXPERT Instrumented Open Flap Assembly experiment has the objective to verify the design/sensor integration and validate the CFD tools. Ground based measurements were made in Europe’s largest high enthalpy plasma facility, Scirocco in Italy. Two EXPERT flaps of the flight article, instrumented with 14 thermocouples, 5 pressure ports, a pyrometer and an IR camera mounted in the cavity instrumented flap will collect in-flight data. During the Scirocco experiment, an EXPERT flap model identical to the flight article was mounted at 45 deg on a holder including cavity and was subjected to a hot plasma flow at an enthalpy up to 11MJ/kg at a stagnation pressure of 7 bar. The test model sports the same pressure sensors as the flight article. Hypersonic state-of-the-art codes were then be used to perform code-to-code and wind tunnel-to-code comparisons, including thermal response of the flap as collected during the tests by the sensors and camera.
Forget Me Not: Dementia in Prison
ERIC Educational Resources Information Center
Maschi, Tina; Kwak, Jung; Ko, Eunjeong; Morrissey, Mary B.
2012-01-01
The number of older adults with dementia in U.S. prisons is rapidly rising. Yet, the vast majority of this marginalized subgroup of the aging population is left neglected behind bars without access to adequate medical and mental health care services. We assert that proactive, interdisciplinary collaborative efforts to improve practice, policy, and…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jetter, R. I.; Messner, M. C.; Sham, T. -L.
The goal of the proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology is to incorporate an SMT data based approach for creep-fatigue damage evaluation into the EPP methodology to avoid the separate evaluation of creep and fatigue damage and eliminate the requirement for stress classification in current methods; thus greatly simplifying evaluation of elevated temperature cyclic service. This methodology should minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed methodology and to verify the applicability of the code rules, analytical studies and evaluation of thermomechanical test results continuedmore » in FY17. This report presents the results of those studies. An EPP strain limits methodology assessment was based on recent two-bar thermal ratcheting test results on 316H stainless steel in the temperature range of 405 to 7050C. Strain range predictions from the EPP evaluation of the two-bar tests were also evaluated and compared with the experimental results. The role of sustained primary loading on cyclic life was assessed using the results of pressurized SMT data from tests on Alloy 617 at 9500C. A viscoplastic material model was used in an analytic simulation of two-bar tests to compare with EPP strain limits assessments using isochronous stress strain curves that are consistent with the viscoplastic material model. A finite element model of a prior 304H stainless steel Oak Ridge National Laboratory (ORNL) nozzle-to-sphere test was developed and used for an EPP strain limits and creep-fatigue code case damage evaluations. A theoretical treatment of a recurring issue with convergence criteria for plastic shakedown illustrated the role of computer machine precision in EPP calculations.« less
NASA Astrophysics Data System (ADS)
Morales-Juberías, R.; Sanchez-Lavega, A.; Hueso, R.; Dowling, T. E.
2001-11-01
We use the EPIC code (Dowling et al. Icarus, 132, 221. 1998) to simulate the merger that took place in March - April 2000 between the white ovals BE and FA (A. Sanchez-Lavega et al., Icarus, 142, 116. 1999, and Icarus, 149, 491. 2001). This merger was the final stage of a more complex interaction that started the 1st of October 1999 involving also the GRS and a small cyclone cell located between the two white ovals. One of the most important issues we try to reproduce here is the observation that the merger at the NH3 cloud level (pressures ~ 0.4 - 1 bars) and in upper levels (hazes at 0.15 - 0.20 bar) was different. While at high altitude the vortices orbited around each other before merging, at the ammonia cloud level they formed a `peanut-shaped' structure without any appreciable rotation before they joined. The other important issue that we try to adjust in our simulations is the critical distance to merge ( ~ 9700 km) as well as the `merging time' ( ~ 21 days) once this critical distance is reached. We present a series of simulations on the stability, motions and interactions of the vortices for different sets of the vertical temperature profile, the zonal wind velocity structure (meridional and vertical profiles), and the intensity and vertical extension of the vortices themselves. The vertical analysis covers a pressure range from 1 mbar to 10 bar, allowing to perform a characterization of the upper Jovian troposphere. This work has been supported by an Spanish - US Fulbright cooperation project (2000-2001). The Spanish team was also supported by MCYT research project PNAYA2000-0932. R. Morales acknowledges a fellowship from Universidad del País Vasco and R. Hueso a postdoctoral fellowship from Gobierno Vasco.
Smoke Not: What Your Country Can Do for You (A Tobacco Use Policy for the U.S. Marine Corps)
1993-03-03
medical malpractice or torts arising from the performance of military duties. The doctrine would probably bar a challenge by an active duty smoker based...can no longer justify to the Anmerican taxpayer the extraordinary expense of medical treatment for Marines who suffer from tobacco related diseases...Lieutenant Colonel, U.S. Marine Corps Department of Oceans Law and Policy Approved by: &avid P. O’Neil Efate Abstract of SMOKE NOT: WHAT YOUR COUNTRY CAN DO
Transmission and storage of medical images with patient information.
Acharya U, Rajendra; Subbanna Bhat, P; Kumar, Sathish; Min, Lim Choo
2003-07-01
Digital watermarking is a technique of hiding specific identification data for copyright authentication. This technique is adapted here for interleaving patient information with medical images, to reduce storage and transmission overheads. The text data is encrypted before interleaving with images to ensure greater security. The graphical signals are interleaved with the image. Two types of error control-coding techniques are proposed to enhance reliability of transmission and storage of medical images interleaved with patient information. Transmission and storage scenarios are simulated with and without error control coding and a qualitative as well as quantitative interpretation of the reliability enhancement resulting from the use of various commonly used error control codes such as repetitive, and (7,4) Hamming code is provided.
The static evolution of the new Italian code of medical ethics.
Montanari Vergallo, G; Busardò, F P; Zaami, S; Marinelli, E
2016-01-01
Eight years since the last revision, in May 2014 the Italian code of medical ethics has been updated. Here, the Authors examine the reform in the light of the increasing difficulties of the medical profession arising from the severity of the Italian law Courts. The most significant aspects of this new code are firstly, the patient's freedom of self-determination and secondly, risk prevention through the disclosure of errors and adverse events. However, in both areas the reform seems to be less effective if we compare the ethical codes of France, the United Kingdom and the United States. In particular, the non-taking into consideration of the said code quality standards and scientific evidence which should guide doctors in their clinical practice is to say the least questionable. Since these are the most significant changes in the new code, it seems inevitable to conclude that the 2014 edition is essentially in line with previous versions. Now more than ever it is necessary that medical ethics acknowledges that medicine, society and medical jurisprudence have changed and doctors must be given new rules in order to protect both patients' rights and dignity of the profession. The physician's right to refuse to perform treatment at odds with his own clinical beliefs cannot be the only mean to safeguard the dignity of the profession. A clear boundary must also be established between medicine and professionalism as well as the criteria in determining the scientific evidences that physicians must follow. This has not been done in the Italian code of ethics, despite all the controversy caused by the Stamina case.
Reed, Terrie L; Kaufman-Rivi, Diana
2010-01-01
The broad array of medical devices and the potential for device failures, malfunctions, and other adverse events associated with each device creates a challenge for public health device surveillance programs. Coding reported events by type of device problem provides one method for identifying a potential signal of a larger device issue. The Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) Event Problem Codes that are used to report adverse events previously lacked a structured set of controls for code development and maintenance. Over time this led to inconsistent, ambiguous, and duplicative concepts being added to the code set on an ad-hoc basis. Recognizing the limitation of its coding system the FDA set out to update the system to improve its usefulness within FDA and as a basis of a global standard to identify important patient and device outcomes throughout the medical community. In 2004, FDA and the National Cancer Institute (NCI) signed a Memorandum of Understanding (MOU) whereby NCI agreed to provide terminology development and maintenance services to all FDA Centers. Under this MOU, CDRH's Office of Surveillance and Biometrics (OSB) convened a cross-Center workgroup and collaborated with staff at NCI Enterprise Vocabulary Service (EVS) to streamline the Patient and Device Problem Codes and integrate them into the NCI Thesaurus and Meta-Thesaurus. This initiative included many enhancements to the Event Problem Codes aimed at improving code selection as well as improving adverse event report analysis. LIMITATIONS & RECOMMENDATIONS: Staff resources, database concerns, and limited collaboration with external groups in the initial phases of the project are discussed. Adverse events associated with medical device use can be better understood when they are reported using a consistent and well-defined code set. This FDA initiative was an attempt to improve the structure and add control mechanisms to an existing code set, improve analysis tools that will better identify device safety trends, and improve the ability to prevent or mitigate effects of adverse events associated with medical device use.
2010-01-01
Background In recent years, several primary care databases recording information from computerized medical records have been established and used for quality assessment of medical care and research. However, to be useful for research purposes, the data generated routinely from every day practice require registration of high quality. In this study we aimed to investigate (i) the frequency and validity of ICD code and drug prescription registration in the new Skaraborg primary care database (SPCD) and (ii) to investigate the sources of variation in this registration. Methods SPCD contains anonymous electronic medical records (ProfDoc III) automatically retrieved from all 24 public health care centres (HCC) in Skaraborg, Sweden. The frequencies of ICD code registration for the selected diagnoses diabetes mellitus, hypertension and chronic cardiovascular disease and the relevant drug prescriptions in the time period between May 2002 and October 2003 were analysed. The validity of data registration in the SPCD was assessed in a random sample of 50 medical records from each HCC (n = 1200 records) using the medical record text as gold standard. The variance of ICD code registration was studied with multi-level logistic regression analysis and expressed as median odds ratio (MOR). Results For diabetes mellitus and hypertension ICD codes were registered in 80-90% of cases, while for congestive heart failure and ischemic heart disease ICD codes were registered more seldom (60-70%). Drug prescription registration was overall high (88%). A correlation between the frequency of ICD coded visits and the sensitivity of the ICD code registration was found for hypertension and congestive heart failure but not for diabetes or ischemic heart disease. The frequency of ICD code registration varied from 42 to 90% between HCCs, and the greatest variation was found at the physician level (MORPHYSICIAN = 4.2 and MORHCC = 2.3). Conclusions Since the frequency of ICD code registration varies between different diagnoses, each diagnosis must be separately validated. Improved frequency and quality of ICD code registration might be achieved by interventions directed towards the physicians where the greatest amount of variation was found. PMID:20416069
Hjerpe, Per; Merlo, Juan; Ohlsson, Henrik; Bengtsson Boström, Kristina; Lindblad, Ulf
2010-04-23
In recent years, several primary care databases recording information from computerized medical records have been established and used for quality assessment of medical care and research. However, to be useful for research purposes, the data generated routinely from every day practice require registration of high quality. In this study we aimed to investigate (i) the frequency and validity of ICD code and drug prescription registration in the new Skaraborg primary care database (SPCD) and (ii) to investigate the sources of variation in this registration. SPCD contains anonymous electronic medical records (ProfDoc III) automatically retrieved from all 24 public health care centres (HCC) in Skaraborg, Sweden. The frequencies of ICD code registration for the selected diagnoses diabetes mellitus, hypertension and chronic cardiovascular disease and the relevant drug prescriptions in the time period between May 2002 and October 2003 were analysed. The validity of data registration in the SPCD was assessed in a random sample of 50 medical records from each HCC (n = 1200 records) using the medical record text as gold standard. The variance of ICD code registration was studied with multi-level logistic regression analysis and expressed as median odds ratio (MOR). For diabetes mellitus and hypertension ICD codes were registered in 80-90% of cases, while for congestive heart failure and ischemic heart disease ICD codes were registered more seldom (60-70%). Drug prescription registration was overall high (88%). A correlation between the frequency of ICD coded visits and the sensitivity of the ICD code registration was found for hypertension and congestive heart failure but not for diabetes or ischemic heart disease.The frequency of ICD code registration varied from 42 to 90% between HCCs, and the greatest variation was found at the physician level (MORPHYSICIAN = 4.2 and MORHCC = 2.3). Since the frequency of ICD code registration varies between different diagnoses, each diagnosis must be separately validated. Improved frequency and quality of ICD code registration might be achieved by interventions directed towards the physicians where the greatest amount of variation was found.
Study on the near-field non-linearity (SMILE) of high power diode laser arrays
NASA Astrophysics Data System (ADS)
Zhang, Hongyou; Jia, Yangtao; Li, Changxuan; Zah, Chung-en; Liu, Xingsheng
2018-02-01
High power laser diodes have been found a wide range of industrial, space, medical applications, characterized by high conversion efficiency, small size, light weight and a long lifetime. However, due to thermal induced stress, each emitter in a semiconductor laser bar or array is displaced along p-n junction, resulting of each emitter is not in a line, called Near-field Non-linearity. Near-field Non-linearity along laser bar (also known as "SMILE") determines the outcome of optical coupling and beam shaping [1]. The SMILE of a laser array is the main obstacle to obtain good optical coupling efficiency and beam shaping from a laser array. Larger SMILE value causes a larger divergence angle and a wider line after collimation and focusing, respectively. In this letter, we simulate two different package structures based on MCC (Micro Channel Cooler) with Indium and AuSn solders, including the distribution of normal stress and the SMILE value. According to the theoretical results, we found the distribution of normal stress on laser bar shows the largest in the middle and drops rapidly near both ends. At last, we did another experiment to prove that the SMILE value of a laser bar was mainly affected by the die bonding process, rather than the operating condition.
High power diode lasers for solid-state laser pumps
NASA Technical Reports Server (NTRS)
Linden, Kurt J.; Mcdonnell, Patrick N.
1994-01-01
The development and commercial application of high power diode laser arrays for use as solid-state laser pumps is described. Such solid-state laser pumps are significantly more efficient and reliable than conventional flash-lamps. This paper describes the design and fabrication of diode lasers emitting in the 780 - 900 nm spectral region, and discusses their performance and reliability. Typical measured performance parameters include electrical-to-optical power conversion efficiencies of 50 percent, narrow-band spectral emission of 2 to 3 nm FWHM, pulsed output power levels of 50 watts/bar with reliability values of over 2 billion shots to date (tests to be terminated after 10 billion shots), and reliable operation to pulse lengths of 1 ms. Pulse lengths up to 5 ms have been demonstrated at derated power levels, and CW performance at various power levels has been evaluated in a 'bar-in-groove' laser package. These high-power 1-cm stacked-bar arrays are now being manufactured for OEM use. Individual diode laser bars, ready for package-mounting by OEM customers, are being sold as commodity items. Commercial and medical applications of these laser arrays include solid-state laser pumping for metal-working, cutting, industrial measurement and control, ranging, wind-shear/atmospheric turbulence detection, X-ray generation, materials surface cleaning, microsurgery, ophthalmology, dermatology, and dental procedures.
Testing the role of bedforms as controls on the morphodynamics of sandy braided rivers with CFD
NASA Astrophysics Data System (ADS)
Unsworth, C. A.; Nicholas, A. P.; Ashworth, P. J.; Best, J.; Lane, S. N.; Parsons, D. R.; Sambrook Smith, G.; Simpson, C.; Strick, R. J. P.
2017-12-01
Sand-bed rivers are characterised by multiple scales of topography (e.g., channels, bars and bedforms). Small scale topographic features (e.g., dunes) exert a significant influence on coherent flow structures and sediment transport processes, over distances that scale with channel depth. However, the extent to which such dune-scale effects control larger, channel and bar-scale morphology and morphodynamics remains unknown. Moreover, such bedform effects are typically neglected in two-dimensional (depth-averaged) morphodynamic models that are used to simulate river evolution. To evaluate the significance of these issues, we report results from a combined numerical modelling and field monitoring study, undertaken in the South Saskatchewan River, Canada. Numerical simulations were carried out, using the OpenFOAM CFD code, to quantify the mean three-dimensional flow structure within a 90 x 350 m section of channel. To isolate the role of bedforms as a control on flow and sediment transport, two simulations were undertaken. The first used a high-resolution ( 3 cm) bedform-resolving DEM. The second used a filtered DEM in which dunes were removed and only large scale topographic features (e.g., bars, scour pools etc) were resolved. The results of these simulations are compared here, in order to quantify the degree to which topographic steering by bedforms influences flow and sediment transport directions at bar and channel scales. Analysis of the CFD simulation results within a 2D morphodynamic modelling framework demonstrates that dunes exert a significant influence on sediment transport, and hence morphodynamics, and highlights important shortcomings in existing 2D model parameterisations of topographic steering.
Representation of tactile curvature in macaque somatosensory area 2
Connor, Charles E.; Hsiao, Steven S.
2013-01-01
Tactile shape information is elaborated in a cortical hierarchy spanning primary (SI) and secondary somatosensory cortex (SII). Indeed, SI neurons in areas 3b and 1 encode simple contour features such as small oriented bars and edges, whereas higher order SII neurons represent large curved contour features such as angles and arcs. However, neural coding of these contour features has not been systematically characterized in area 2, the most caudal SI subdivision in the postcentral gyrus. In the present study, we analyzed area 2 neural responses to embossed oriented bars and curved contour fragments to establish whether curvature representations are generated in the postcentral gyrus. We found that many area 2 neurons (26 of 112) exhibit clear curvature tuning, preferring contours pointing in a particular direction. Fewer area 2 neurons (15 of 112) show preferences for oriented bars. Because area 2 response patterns closely resembled SII patterns, we also compared area 2 and SII response time courses to characterize the temporal dynamics of curvature synthesis in the somatosensory system. We found that curvature representations develop and peak concurrently in area 2 and SII. These results reveal that transitions from orientation tuning to curvature selectivity in the somatosensory cortical hierarchy occur within SI rather than between SI and SII. PMID:23536717
A binary link tracker for the BaBar level 1 trigger system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berenyi, A.; Chen, H.K.; Dao, K.
1999-08-01
The BaBar detector at PEP-II will operate in a high-luminosity e{sup +}e{sup {minus}} collider environment near the {Upsilon}(4S) resonance with the primary goal of studying CP violation in the B meson system. In this environment, typical physics events of interest involve multiple charged particles. These events are identified by counting these tracks in a fast first level (Level 1) trigger system, by reconstructing the tracks in real time. For this purpose, a Binary Link Tracker Module (BLTM) was designed and fabricated for the BaBar Level 1 Drift Chamber trigger system. The BLTM is responsible for linking track segments, constructed bymore » the Track Segment Finder Modules (TSFM), into complete tracks. A single BLTM module processes a 360 MBytes/s stream of segment hit data, corresponding to information from the entire Drift Chamber, and implements a fast and robust algorithm that tolerates high hit occupancies as well as local inefficiencies of the Drift Chamber. The algorithms and the necessary control logic of the BLTM were implemented in Field Programmable Gate Arrays (FPGAs), using the VHDL hardware description language. The finished 9U x 400 mm Euro-format board contains roughly 75,000 gates of programmable logic or about 10,000 lines of VHDL code synthesized into five FPGAs.« less
Explosive Characteristics of Carbonaceous Nanoparticles
NASA Astrophysics Data System (ADS)
Turkevich, Leonid; Fernback, Joseph; Dastidar, Ashok
2013-03-01
Explosion testing has been performed on 20 codes of carbonaceous particles. These include SWCNTs (single-walled carbon nanotubes), MWCNTs (multi-walled carbon nanotubes), CNFs (carbon nanofibers), graphene, diamond, fullerene, carbon blacks and graphites. Explosion screening was performed in a 20 L explosion chamber (ASTM E1226-10 protocol), at a (dilute) concentration of 500 g/m3, using a 5 kJ ignition source. Time traces of overpressure were recorded. Samples exhibited overpressures of 5-7 bar, and deflagration index KSt = V1/3 (dp/pt)max ~ 10 - 80 bar-m/s, which places these materials in European Dust Explosion Class St-1 (similar to cotton and wood dust). There was minimal variation between these different materials. The explosive characteristics of these carbonaceous powders are uncorrelated with particle size (BET specific surface area). Additional tests were performed on selected materials to identify minimum explosive concentration [MEC]. These materials exhibit MEC ~ 101 -102 g/m3 (lower than the MEC for coals). The concentration scans confirm that the earlier screening was performed under fuel-rich conditions (i.e. the maximum over-pressure and deflagration index exceed the screening values); e.g. the true fullerene KSt ~ 200 bar-m/s, placing it borderline St-1/St-2. Work supported through the NIOSH Nanotechnology Research Center (NTRC)
Effects of object shape on the visual guidance of action.
Eloka, Owino; Franz, Volker H
2011-04-22
Little is known of how visual coding of the shape of an object affects grasping movements. We addressed this issue by investigating the influence of shape perturbations on grasping. Twenty-six participants grasped a disc or a bar that were chosen such that they could in principle be grasped with identical movements (i.e., relevant sizes were identical such that the final grips consisted of identical separations of the fingers and no parts of the objects constituted obstacles for the movement). Nevertheless, participants took object shape into account and grasped the bar with a larger maximum grip aperture and a different hand angle than the disc. In 20% of the trials, the object changed its shape from bar to disc or vice versa early or late during the movement. If there was enough time (early perturbations), grasps were often adapted in flight to the new shape. These results show that the motor system takes into account even small and seemingly irrelevant changes of object shape and adapts the movement in a fine-grained manner. Although this adaptation might seem computationally expensive, we presume that its benefits (e.g., a more comfortable and more accurate movement) outweigh the costs. Copyright © 2011 Elsevier Ltd. All rights reserved.
Subotin, Michael; Davis, Anthony R
2016-09-01
Natural language processing methods for medical auto-coding, or automatic generation of medical billing codes from electronic health records, generally assign each code independently of the others. They may thus assign codes for closely related procedures or diagnoses to the same document, even when they do not tend to occur together in practice, simply because the right choice can be difficult to infer from the clinical narrative. We propose a method that injects awareness of the propensities for code co-occurrence into this process. First, a model is trained to estimate the conditional probability that one code is assigned by a human coder, given than another code is known to have been assigned to the same document. Then, at runtime, an iterative algorithm is used to apply this model to the output of an existing statistical auto-coder to modify the confidence scores of the codes. We tested this method in combination with a primary auto-coder for International Statistical Classification of Diseases-10 procedure codes, achieving a 12% relative improvement in F-score over the primary auto-coder baseline. The proposed method can be used, with appropriate features, in combination with any auto-coder that generates codes with different levels of confidence. The promising results obtained for International Statistical Classification of Diseases-10 procedure codes suggest that the proposed method may have wider applications in auto-coding. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Portal of medical data models: information infrastructure for medical research and healthcare.
Dugas, Martin; Neuhaus, Philipp; Meidt, Alexandra; Doods, Justin; Storck, Michael; Bruland, Philipp; Varghese, Julian
2016-01-01
Information systems are a key success factor for medical research and healthcare. Currently, most of these systems apply heterogeneous and proprietary data models, which impede data exchange and integrated data analysis for scientific purposes. Due to the complexity of medical terminology, the overall number of medical data models is very high. At present, the vast majority of these models are not available to the scientific community. The objective of the Portal of Medical Data Models (MDM, https://medical-data-models.org) is to foster sharing of medical data models. MDM is a registered European information infrastructure. It provides a multilingual platform for exchange and discussion of data models in medicine, both for medical research and healthcare. The system is developed in collaboration with the University Library of Münster to ensure sustainability. A web front-end enables users to search, view, download and discuss data models. Eleven different export formats are available (ODM, PDF, CDA, CSV, MACRO-XML, REDCap, SQL, SPSS, ADL, R, XLSX). MDM contents were analysed with descriptive statistics. MDM contains 4387 current versions of data models (in total 10,963 versions). 2475 of these models belong to oncology trials. The most common keyword (n = 3826) is 'Clinical Trial'; most frequent diseases are breast cancer, leukemia, lung and colorectal neoplasms. Most common languages of data elements are English (n = 328,557) and German (n = 68,738). Semantic annotations (UMLS codes) are available for 108,412 data items, 2453 item groups and 35,361 code list items. Overall 335,087 UMLS codes are assigned with 21,847 unique codes. Few UMLS codes are used several thousand times, but there is a long tail of rarely used codes in the frequency distribution. Expected benefits of the MDM portal are improved and accelerated design of medical data models by sharing best practice, more standardised data models with semantic annotation and better information exchange between information systems, in particular Electronic Data Capture (EDC) and Electronic Health Records (EHR) systems. Contents of the MDM portal need to be further expanded to reach broad coverage of all relevant medical domains. Database URL: https://medical-data-models.org. © The Author(s) 2016. Published by Oxford University Press.
Grinding model and material removal mechanism of medical nanometer zirconia ceramics.
Zhang, Dongkun; Li, Changhe; Jia, Dongzhou; Wang, Sheng; Li, Runze; Qi, Xiaoxiao
2014-01-01
Many patents have been devoted to developing medical nanometer zirconia ceramic grinding techniques that can significantly improve both workpiece surface integrity and grinding quality. Among these patents is a process for preparing ceramic dental implants with a surface for improving osseo-integration by sand abrasive finishing under a jet pressure of 1.5 bar to 8.0 bar and with a grain size of 30 µm to 250 µm. Compared with other materials, nano-zirconia ceramics exhibit unmatched biomedical performance and excellent mechanical properties as medical bone tissue and dentures. The removal mechanism of nano-zirconia materials includes brittle fracture and plastic removal. Brittle fracture involves crack formation, extension, peeling, and chipping to completely remove debris. Plastic removal is similar to chip formation in metal grinding, including rubbing, ploughing, and the formation of grinding debris. The materials are removed in shearing and chipping. During brittle fracture, the grinding-led transverse and radial extension of cracks further generate local peeling of blocks of the material. In material peeling and removal, the mechanical strength and surface quality of the workpiece are also greatly reduced because of crack extension. When grinding occurs in the plastic region, plastic removal is performed, and surface grinding does not generate grinding fissures and surface fracture, producing clinically satisfactory grinding quality. With certain grinding conditions, medical nanometer zirconia ceramics can be removed through plastic flow in ductile regime. In this study, we analyzed the critical conditions for the transfer of brittle and plastic removal in nano-zirconia ceramic grinding as well as the high-quality surface grinding of medical nanometer zirconia ceramics by ELID grinding.
[How do first codes of medical ethics inspire contemporary physicians?].
Paprocka-Lipińska, Anna; Basińska, Krystyna
2014-02-01
First codes of medical ethics appeared between 18th and 19th century. Their formation was inspired by changes that happened in medicine, positive in general but with some negative setbacks. Those negative consequences revealed the need to codify all those ethical duties, which were formerly passed from generation to generation by the word of mouth and individual example by master physicians. 210 years has passed since the publication of "Medical Ethics" by Thomas Percival, yet essential ethical guidelines remain the same. Similarly, ethical codes published in Poland in 19 century can still be an inspiration to modem physicians.
Bhattacharya, Moumita; Jurkovitz, Claudine; Shatkay, Hagit
2018-04-12
Patients associated with multiple co-occurring health conditions often face aggravated complications and less favorable outcomes. Co-occurring conditions are especially prevalent among individuals suffering from kidney disease, an increasingly widespread condition affecting 13% of the general population in the US. This study aims to identify and characterize patterns of co-occurring medical conditions in patients employing a probabilistic framework. Specifically, we apply topic modeling in a non-traditional way to find associations across SNOMED-CT codes assigned and recorded in the EHRs of >13,000 patients diagnosed with kidney disease. Unlike most prior work on topic modeling, we apply the method to codes rather than to natural language. Moreover, we quantitatively evaluate the topics, assessing their tightness and distinctiveness, and also assess the medical validity of our results. Our experiments show that each topic is succinctly characterized by a few highly probable and unique disease codes, indicating that the topics are tight. Furthermore, inter-topic distance between each pair of topics is typically high, illustrating distinctiveness. Last, most coded conditions grouped together within a topic, are indeed reported to co-occur in the medical literature. Notably, our results uncover a few indirect associations among conditions that have hitherto not been reported as correlated in the medical literature. Copyright © 2018. Published by Elsevier Inc.
Kavuluru, Ramakanth; Rios, Anthony; Lu, Yuan
2015-01-01
Background Diagnosis codes are assigned to medical records in healthcare facilities by trained coders by reviewing all physician authored documents associated with a patient's visit. This is a necessary and complex task involving coders adhering to coding guidelines and coding all assignable codes. With the popularity of electronic medical records (EMRs), computational approaches to code assignment have been proposed in the recent years. However, most efforts have focused on single and often short clinical narratives, while realistic scenarios warrant full EMR level analysis for code assignment. Objective We evaluate supervised learning approaches to automatically assign international classification of diseases (ninth revision) - clinical modification (ICD-9-CM) codes to EMRs by experimenting with a large realistic EMR dataset. The overall goal is to identify methods that offer superior performance in this task when considering such datasets. Methods We use a dataset of 71,463 EMRs corresponding to in-patient visits with discharge date falling in a two year period (2011–2012) from the University of Kentucky (UKY) Medical Center. We curate a smaller subset of this dataset and also use a third gold standard dataset of radiology reports. We conduct experiments using different problem transformation approaches with feature and data selection components and employing suitable label calibration and ranking methods with novel features involving code co-occurrence frequencies and latent code associations. Results Over all codes with at least 50 training examples we obtain a micro F-score of 0.48. On the set of codes that occur at least in 1% of the two year dataset, we achieve a micro F-score of 0.54. For the smaller radiology report dataset, the classifier chaining approach yields best results. For the smaller subset of the UKY dataset, feature selection, data selection, and label calibration offer best performance. Conclusions We show that datasets at different scale (size of the EMRs, number of distinct codes) and with different characteristics warrant different learning approaches. For shorter narratives pertaining to a particular medical subdomain (e.g., radiology, pathology), classifier chaining is ideal given the codes are highly related with each other. For realistic in-patient full EMRs, feature and data selection methods offer high performance for smaller datasets. However, for large EMR datasets, we observe that the binary relevance approach with learning-to-rank based code reranking offers the best performance. Regardless of the training dataset size, for general EMRs, label calibration to select the optimal number of labels is an indispensable final step. PMID:26054428
Kavuluru, Ramakanth; Rios, Anthony; Lu, Yuan
2015-10-01
Diagnosis codes are assigned to medical records in healthcare facilities by trained coders by reviewing all physician authored documents associated with a patient's visit. This is a necessary and complex task involving coders adhering to coding guidelines and coding all assignable codes. With the popularity of electronic medical records (EMRs), computational approaches to code assignment have been proposed in the recent years. However, most efforts have focused on single and often short clinical narratives, while realistic scenarios warrant full EMR level analysis for code assignment. We evaluate supervised learning approaches to automatically assign international classification of diseases (ninth revision) - clinical modification (ICD-9-CM) codes to EMRs by experimenting with a large realistic EMR dataset. The overall goal is to identify methods that offer superior performance in this task when considering such datasets. We use a dataset of 71,463 EMRs corresponding to in-patient visits with discharge date falling in a two year period (2011-2012) from the University of Kentucky (UKY) Medical Center. We curate a smaller subset of this dataset and also use a third gold standard dataset of radiology reports. We conduct experiments using different problem transformation approaches with feature and data selection components and employing suitable label calibration and ranking methods with novel features involving code co-occurrence frequencies and latent code associations. Over all codes with at least 50 training examples we obtain a micro F-score of 0.48. On the set of codes that occur at least in 1% of the two year dataset, we achieve a micro F-score of 0.54. For the smaller radiology report dataset, the classifier chaining approach yields best results. For the smaller subset of the UKY dataset, feature selection, data selection, and label calibration offer best performance. We show that datasets at different scale (size of the EMRs, number of distinct codes) and with different characteristics warrant different learning approaches. For shorter narratives pertaining to a particular medical subdomain (e.g., radiology, pathology), classifier chaining is ideal given the codes are highly related with each other. For realistic in-patient full EMRs, feature and data selection methods offer high performance for smaller datasets. However, for large EMR datasets, we observe that the binary relevance approach with learning-to-rank based code reranking offers the best performance. Regardless of the training dataset size, for general EMRs, label calibration to select the optimal number of labels is an indispensable final step. Copyright © 2015 Elsevier B.V. All rights reserved.
Morphodynamics structures induced by variations of the channel width
NASA Astrophysics Data System (ADS)
Duro, Gonzalo; Crosato, Alessandra; Tassi, Pablo
2014-05-01
In alluvial channels, forcing effects, such as a longitudinally varying width, can induce the formation of steady bars (Olesen, 1984). The type of bars that form, such as alternate, central or multiple, will mainly depend on the local flow width-to-depth ratio and on upstream conditions (Struiksma et al., 1985). The effects on bar formation of varying the channel width received attention only recently and investigations, based on flume experiments and mathematical modelling, are mostly restricted to small longitudinal sinusoidal variations of the channel width (e.g. Repetto et al., 2002; Wu and Yeh, 2005, Zolezzi et al., 2012; Frascati and Lanzoni, 2013). In this work, we analyze the variations in equilibrium bed topography in a longitudinal width-varying channel with characteristic scales of the Waal River (The Netherlands) using two different 2D depth-averaged morphodynamic models, one based on the Delft3D code and one on Telemac-Mascaret system. In particular, we explore the effects of changing the wavelength of sinusoidal width variations in a straight channel, focusing on the effects of the spatial lag between bar formation and forcing that is observed in numerical models and laboratory experiments (e.g. Crosato et al, 2011). We extend the investigations to finite width variations in which longitudinal changes of the width-to-depth ratio are such that they may affect the type of bars that become unstable (alternate, central or multiple bars). Numerical results are qualitatively validated with field observations and the resulting morphodynamic pattern is compared with the physics-based predictor of river bar modes by Crosato and Mosselman (2009). The numerical models are finally used to analyse the experimental conditions of Wu and Yeh (2005). The study should be seen as merely exploratory. The aim is to investigate possible approaches for future research aiming at assessing the effects of artificial river widening and narrowing to control bar formation in alluvial rivers. References Crosato A. and Mosselman E., 2009. Simple physics-based predictor for the number of river bars and the transition between meandering and braiding. Water Resources Research, 45, W03424, doi: 10.1029/2008WR007242. Crosato A., Mosselman E., Desta F.B. and Uijttewaal W.S.J., 2011. Experimental and numerical evidence for intrinsic nonmigrating bars in alluvial channels. Water Resources Research, AGU, 47(3), W03511, doi 10.1029/2010WR009714. Frascati A. and Lanzoni S., 2013. A mathematical model for meandering rivers with varying width. J. Geophys. Res.Earth Surf., 118, doi:10.1002/jgrf.20084. Olesen K.W., 1984. Alternate bars in and meandering of alluvial rivers. In: River Meandering, Proc. of the Conf. Rivers '83, 24-26 Oct. 1983, New Orleans, Louisiana, U.S.A., ed. Elliott C.M., pp. 873-884, ASCE, New York. ISBN 0-87262-393-9. Repetto R., Tubino, M. and Paola C., 2002. Planimetric instability of channels with variable width. J. Fluid Mech., 457, 79-109. Struiksma N., Olesen K.W., Flokstra C. and De Vriend H.J., 1985. Bed deformation in curved alluvial channels. J. Hydraul. Res., 23(1), 57- 79. Wu F.-C. and Yeh T.-H., 2005. Forced bars induced by variations of channel width: Implications for incipient bifurcation. J. Geophys. Res., 110, F02009, doi:10.1029/2004JF000160. Zolezzi, G., R. Luchi, and M. Tubino (2012), Modeling morphodynamic processes in meandering rivers with spatial width variations, Rev. Geophys., 50, RG4005, doi:10.1029/2012RG000392.
Medical data protection: a proposal for a deontology code.
Gritzalis, D; Tomaras, A; Katsikas, S; Keklikoglou, J
1990-12-01
In this paper, a proposal for a Medical Data Protection Deontology Code in Greece is presented. Undoubtedly, this code should also be of interest to other countries. The whole effort for the composition of this code is based on what holds internationally, particularly in the EC countries, on recent data acquired from Greek sources and on the experience resulting from what is acceptable in Greece. Accordingly, policies and their influence on the protection of health data, as well as main problems related to that protection, have been considered.
Medical reliable network using concatenated channel codes through GSM network.
Ahmed, Emtithal; Kohno, Ryuji
2013-01-01
Although the 4(th) generation (4G) of global mobile communication network, i.e. Long Term Evolution (LTE) coexisting with the 3(rd) generation (3G) has successfully started; the 2(nd) generation (2G), i.e. Global System for Mobile communication (GSM) still playing an important role in many developing countries. Without any other reliable network infrastructure, GSM can be applied for tele-monitoring applications, where high mobility and low cost are necessary. A core objective of this paper is to introduce the design of a more reliable and dependable Medical Network Channel Code system (MNCC) through GSM Network. MNCC design based on simple concatenated channel code, which is cascade of an inner code (GSM) and an extra outer code (Convolution Code) in order to protect medical data more robust against channel errors than other data using the existing GSM network. In this paper, the MNCC system will provide Bit Error Rate (BER) equivalent to the BER for medical tele monitoring of physiological signals, which is 10(-5) or less. The performance of the MNCC has been proven and investigated using computer simulations under different channels condition such as, Additive White Gaussian Noise (AWGN), Rayleigh noise and burst noise. Generally the MNCC system has been providing better performance as compared to GSM.
“Blurred Lines?”1 Sexual Aggression and Barroom Culture
Graham, Kathryn; Bernards, Sharon; Osgood, D. Wayne; Abbey, Antonia; Parks, Michael; Flynn, Andrea; Dumas, Tara; Wells, Samantha
2014-01-01
Background Meeting potential sexual/romantic partners for mutual pleasure is one of the main reasons young adults go to bars. However, not all sexual contacts are positive and consensual, and aggression related to sexual advances is a common experience. Sometimes such aggression is related to misperceptions in making and receiving sexual advances while other times aggression reflects intentional harassment or other sexually aggressive acts. The present study uses objective observational research to assess quantitatively gender of initiators and targets and the extent that sexual aggression involves intentional aggression by the initiator, the nature of responses by targets, and the role of third parties and intoxication. Methods We analyzed 258 aggressive incidents involving sexual advances observed as part of a larger study on aggression in large capacity bars and clubs, using variables collected as part of the original research (gender, intoxication, intent) and variables coded from narrative descriptions (invasiveness, persistence, targets’ responses, role of third parties). Hierarchical Linear Modeling (HLM) analyses were used to account for nesting on incidents in evening and bars. Results 90% of incidents involved male initiators and female targets, with almost all incidents involving intentional or probably intentional aggression. Targets mostly responded nonaggressively, usually using evasion to end the incident. Staff rarely intervened; patron third parties intervened in 21% of incidents, usually to help the target but sometimes to encourage the initiator. Initiators’ level of invasiveness was related to intoxication of the targets but not their own intoxication, suggesting intoxicated women were being targeted. Conclusions Sexual aggression is a major problem in bars often reflecting intentional sexual invasiveness and unwanted persistence rather than misperceptions in sexual advances. Prevention needs to focus on addressing masculinity norms of male patrons and staff that support sexual aggression and better management of the highly sexualized and sexist environments of most bars. PMID:24588839
Locating and classifying defects using an hybrid data base
NASA Astrophysics Data System (ADS)
Luna-Avilés, A.; Hernández-Gómez, L. H.; Durodola, J. F.; Urriolagoitia-Calderón, G.; Urriolagoitia-Sosa, G.; Beltrán Fernández, J. A.; Díaz Pineda, A.
2011-07-01
A computational inverse technique was used in the localization and classification of defects. Postulated voids of two different sizes (2 mm and 4 mm diameter) were introduced in PMMA bars with and without a notch. The bar dimensions are 200×20×5 mm. One half of them were plain and the other half has a notch (3 mm × 4 mm) which is close to the defect area (19 mm × 16 mm).This analysis was done with an Artificial Neural Network (ANN) and its optimization was done with an Adaptive Neuro Fuzzy Procedure (ANFIS). A hybrid data base was developed with numerical and experimental results. Synthetic data was generated with the finite element method using SOLID95 element of ANSYS code. A parametric analysis was carried out. Only one defect in such bars was taken into account and the first five natural frequencies were calculated. 460 cases were evaluated. Half of them were plain and the other half has a notch. All the input data was classified in two groups. Each one has 230 cases and corresponds to one of the two sort of voids mentioned above. On the other hand, experimental analysis was carried on with PMMA specimens of the same size. The first two natural frequencies of 40 cases were obtained with one void. The other three frequencies were obtained numerically. 20 of these bars were plain and the others have a notch. These experimental results were introduced in the synthetic data base. 400 cases were taken randomly and, with this information, the ANN was trained with the backpropagation algorithm. The accuracy of the results was tested with the 100 cases that were left. In the next stage of this work, the ANN output was optimized with ANFIS. Previous papers showed that localization and classification of defects was reduced as notches were introduced in such bars. In the case of this paper, improved results were obtained when a hybrid data base was used.
Wiley, Kevin F; Yousuf, Tariq; Pasque, Charles B; Yousuf, Khalid
2014-06-01
Medical knowledge and surgical skills are necessary to become an effective orthopedic surgeon. To run an efficient practice, the surgeon must also possess a basic understanding of medical business practices, including billing and coding. In this study, we surveyed and compared the level of billing and coding knowledge among current orthopedic residents PGY3 and higher, academic and private practice attending orthopedic surgeons, and orthopedic coding professionals. According to the survey results, residents and fellows have a similar knowledge of coding and billing, regardless of their level of training or type of business education received in residency. Most residents would like formal training in coding, billing, and practice management didactics; this is consistent with data from previous studies.
The new CMSS code for interactions with companies managing relationships to minimize conflicts.
Kahn, Norman B; Lichter, Allen S
2011-09-01
Conflicts of interest in medicine have received significant attention in recent years, through the public and professional media, federal and state governments, and through a 2009 report of the Institute of Medicine on Conflict of Interest in Medical Research, Education and Practice. The Council of Medical Specialty Societies (CMSS) Code for Interactions with Companies was adopted by the CMSS in April 2010. The Code guides specialty societies in the profession of medicine in ethical relationships between societies and the pharmaceutical and medical device industries. The Code serves to protect and promote the independence of specialty societies and their leaders in corporate sponsorships, licensing, advertising, society meetings, exhibits, educational programs, journals, clinical practice guidelines, and research. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Open Mess Management Career Ladder AFS 742X0 and CEM Code 74200.
1980-12-01
I. OPEN MESS MANAGERS (SPC049, N=187) 11. FOOD / BEVERAGE OPERATIONS ASSISTANI MANAGERS ’LUSTER (GRP076, N=92) a. Bar and Operations Managers (GKP085...said they will or probably will reenlist. 1I. FOOD / BEVERAGE OPERATIONS ASSISTANT MANAGERS CLUSTER (GRP076).- This cluster of 9-2 reslpo nrts-(23...operation of open mess food and beverage functions. The majority of these airmen identify themselves as Assistant Managers of open mess facilities and are
Eddy current NDE performance demonstrations using simulation tools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maurice, L.; Costan, V.; Guillot, E.
2013-01-25
To carry out performance demonstrations of the Eddy-Current NDE processes applied on French nuclear power plants, EDF studies the possibility of using simulation tools as an alternative to measurements on steam generator tube mocks-up. This paper focuses on the strategy led by EDF to assess and use code{sub C}armel3D and Civa, on the case of Eddy-Current NDE on wears problem which may appear in the U-shape region of steam generator tubes due to the rubbing of anti-vibration bars.
Advanced Data Collection for Inventory Management
NASA Technical Reports Server (NTRS)
Opresko, G. A.; Leet, J. H.; Mcgrath, D. F.; Eidson, J.
1987-01-01
Bar-coding, radio-frequency, and voice-operated systems selected. Report discusses study of state-of-the-art in automated collection of data for management of large inventories. Study included comprehensive search of literature on data collection and inventory management, visits to existing automated inventory systems, and tours of selected supply and transportation facilities at Kennedy Space Center. Information collected analyzed in view of needs of conceptual inventory-management systems for Kennedy Space Center and for manned space station and other future space projects.
Method for imaging informational biological molecules on a semiconductor substrate
NASA Technical Reports Server (NTRS)
Coles, L. Stephen (Inventor)
1994-01-01
Imaging biological molecules such as DNA at rates several times faster than conventional imaging techniques is carried out using a patterned silicon wafer having nano-machined grooves which hold individual molecular strands and periodically spaced unique bar codes permitting repeatably locating all images. The strands are coaxed into the grooves preferably using gravity and pulsed electric fields which induce electric charge attraction to the molecular strands in the bottom surfaces of the grooves. Differential imaging removes substrate artifacts.
Bar Code Applications at the Naval Publications and Forms Center.
1986-07-01
Note 4 811 758 NAVAIR 0 0 See Note 4 813 469 NAVAIR 0 0 See Note 4 816 10062 NAVAIR 0 0 See Note 4 818 8366 NAVAIR 0 0 See Note 4 819 1392 NAVAiR 0 0...816 10062 NAVAIR 0 0 See Note 4 818 8366 NAVAIR 0 0 See Note 4 819 1392 NAVAIR 0 0 See Nole 4 850 255 NAVAIR 0 0 See Note 4 851 272 NAVAIR 0 0 See Note
Using Gene Transcription Patterns (Bar Coding Scans) to Guide Wound Debridement and Healing
Tomic-Canic, Marjana; Ayello, Elizabeth A.; Stojadinovic, Olivera; Golinko, Michael S.; Brem, Harold
2010-01-01
PURPOSE To acquaint wound care practitioners with new information related to debridement of chronic wounds. TARGET AUDIENCE This continuing education activity is intended for physicians and nurses with an interest in wound care. OBJECTIVES After reading this article and taking this test, the reader should be able to: Explain the role of keratinocytes in wound healing. Discuss new research findings on the physiological differences between healing and nonhealing wounds. Identify implications of the new research for debridement of chronic wounds. PMID:18836328
Normative lessons: codes of conduct, self-regulation and the law.
Parker, Malcolm H
2010-06-07
Good medical practice: a code of conduct for doctors in Australia provides uniform standards to be applied in relation to complaints about doctors to the new Medical Board of Australia. The draft Code was criticised for being prescriptive. The final Code employs apparently less authoritative wording than the draft Code, but the implicit obligations it contains are no less prescriptive. Although the draft Code was thought to potentially undermine trust in doctors, and stifle professional judgement in relation to individual patients, its general obligations always allowed for flexibility of application, depending on the circumstances of individual patients. Professional codes may contain some aspirational statements, but they always contain authoritative ones, and they share this feature with legal codes. In successfully diluting the apparent prescriptivity of the draft Code, the profession has lost an opportunity to demonstrate its commitment to the raison d'etre of self-regulation - the protection of patients. Professional codes are not opportunities for reflection, consideration and debate, but are outcomes of these activities.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-18
...The United States Patent and Trademark Office (Office or USPTO) proposes to align the USPTO's professional responsibility rules with those of most other U.S. jurisdictions by replacing the current Patent and Trademark Office Code of Professional Responsibility, adopted in 1985, based on the 1980 version of the Model Code of Professional Responsibility of the American Bar Association (``ABA''), with new USPTO Rules of Professional Conduct, which are based on the Model Rules of Professional Conduct of the ABA, which were published in 1983, substantially revised in 2003 and updated through 2011. Changes approved by the ABA House of Delegates in August 2012 have not been incorporated in these proposed rules. The Office also proposes to revise the existing procedural rules governing disciplinary investigations and proceedings.
U.S. EPA, Pesticide Product Label, KING-K BAR-FLY BLOCK, MEDICATED, 03/04/1969
2011-04-21
... Cobal t (Co ) • • • • not. lea. than • • · • .rXn1 Total 3U,are (As invert) • not lees thar: • • • · 20.00f. Choline :hlorlde. • • • • IIgs/lb. . • • · 7C;.O~ ...
ERIC Educational Resources Information Center
Latham, Patricia H.; Latham, Peter S.
1998-01-01
Reviews court decisions regarding the documentation of disabilities and accommodations for individuals with learning disabilities and/or attention-deficit disorders taking licensing examinations from the National Board of Medical Examiners and the State Bar Examiners. Professional schools and licensing authorities are urged to work toward…
Coded excitation ultrasonic needle tracking: An in vivo study.
Xia, Wenfeng; Ginsberg, Yuval; West, Simeon J; Nikitichev, Daniil I; Ourselin, Sebastien; David, Anna L; Desjardins, Adrien E
2016-07-01
Accurate and efficient guidance of medical devices to procedural targets lies at the heart of interventional procedures. Ultrasound imaging is commonly used for device guidance, but determining the location of the device tip can be challenging. Various methods have been proposed to track medical devices during ultrasound-guided procedures, but widespread clinical adoption has remained elusive. With ultrasonic tracking, the location of a medical device is determined by ultrasonic communication between the ultrasound imaging probe and a transducer integrated into the medical device. The signal-to-noise ratio (SNR) of the transducer data is an important determinant of the depth in tissue at which tracking can be performed. In this paper, the authors present a new generation of ultrasonic tracking in which coded excitation is used to improve the SNR without spatial averaging. A fiber optic hydrophone was integrated into the cannula of a 20 gauge insertion needle. This transducer received transmissions from the ultrasound imaging probe, and the data were processed to obtain a tracking image of the needle tip. Excitation using Barker or Golay codes was performed to improve the SNR, and conventional bipolar excitation was performed for comparison. The performance of the coded excitation ultrasonic tracking system was evaluated in an in vivo ovine model with insertions to the brachial plexus and the uterine cavity. Coded excitation significantly increased the SNRs of the tracking images, as compared with bipolar excitation. During an insertion to the brachial plexus, the SNR was increased by factors of 3.5 for Barker coding and 7.1 for Golay coding. During insertions into the uterine cavity, these factors ranged from 2.9 to 4.2 for Barker coding and 5.4 to 8.5 for Golay coding. The maximum SNR was 670, which was obtained with Golay coding during needle withdrawal from the brachial plexus. Range sidelobe artifacts were observed in tracking images obtained with Barker coded excitation, and they were visually absent with Golay coded excitation. The spatial tracking accuracy was unaffected by coded excitation. Coded excitation is a viable method for improving the SNR in ultrasonic tracking without compromising spatial accuracy. This method provided SNR increases that are consistent with theoretical expectations, even in the presence of physiological motion. With the ultrasonic tracking system in this study, the SNR increases will have direct clinical implications in a broad range of interventional procedures by improving visibility of medical devices at large depths.
NASA Astrophysics Data System (ADS)
Zorn, Martin; Hülsewede, Ralf; Pietrzak, Agnieszka; Meusel, Jens; Sebastian, Jürgen
2015-03-01
Laser bars, laser arrays, and single emitters are highly-desired light sources e.g. for direct material processing, pump sources for solid state and fiber lasers or medical applications. These sources require high output powers with optimal efficiency together with good reliability resulting in a long lifetime of the device. Desired wavelengths range from 760 nm in esthetic skin treatment over 915 nm, 940 nm and 976 nm to 1030 nm for direct material processing and pumping applications. In this publication we present our latest developments for the different application-defined wavelengths in continuouswave operation mode. At 760nm laser bars with 30 % filling factor and 1.5 mm resonator length show optical output powers around 90-100 W using an optimized design. For longer wavelengths between 915 nm and 1030 nm laser bars with 4 mm resonator length and 50 % filling factor show reliable output powers above 200 W. The efficiency reached lies above 60% and the slow axis divergence (95% power content) is below 7°. Further developments of bars tailored for 940 nm emission wavelength reach output powers of 350 W. Reliable single emitters for effective fiber coupling having emitter widths of 90 μm and 195 μm are presented. They emit optical powers of 12 W and 24 W, respectively, at emission wavelengths of 915 nm, 940 nm and 976 nm. Moreover, reliability tests of 90 μm-single emitters at a power level of 12W currently show a life time over 3500 h.
The View Behind and Ahead: Implications of Certification *
Darling, Louise
1973-01-01
The Medical Library Association's certification plan, never of real significance in employment and promotion practices in health sciences librarianship, does not reflect the many changes which have occurred in swift progression since adoption of the code in 1949. Solutions to the problems which have accumulated since then are sought in a brief examination of trends in credentialing and certification in the health professions and in the library field, both general and special. Emphasis is given to the historical development of provisions in the MLA Code for the Training and Certification of Medical Librarians, the limited opportunity for practical implementation of most of the provisions, the importance of the code in stimulating the Association's educational programs, the impact of the Medical Library Assistance Act, Regional Medical Programs, and increases in demand for health information on manpower requirements for health science libraries, the specific dissatisfactions MLA members have expressed over certification, and the role of the Ad Hoc Committee to Develop a New Certification Code. PMID:4744343
The Italian Code of Medical Deontology: characterizing features of its 2014 edition.
Conti, Andrea Alberto
2015-09-14
The latest edition of the Italian Code of Medical Deontology has been released by the Italian Federation of the Registers of Physicians and Dentists in May 2014 (1). The previous edition of the Italian Code dated back to 2006 (2), and it has been integrated and updated by a multi-professional and inter-disciplinary panel involving, besides physicians, representatives of scientific societies and trade unions, jurisconsults and experts in bioethics....
Musculoskeletal disorder costs and medical claim filing in the US retail trade sector.
Bhattacharya, Anasua; Leigh, J Paul
2011-01-01
The average costs of Musculoskeletal Disorder (MSD) and odds ratios for filing medical claims related to MSD were examined. The medical claims were identified by ICD 9 codes for four US Census regions within retail trade. Large private firms' medical claims data from Thomson Reuters Inc. MarketScan databases for the years 2003 through 2006 were used. Average costs were highest for claims related to lumbar region (ICD 9 Code: 724.02) and number of claims were largest for low back syndrome (ICD 9 Code: 724.2). Whereas the odds of filing an MSD claim did not vary greatly over time, average costs declined over time. The odds of filing claims rose with age and were higher for females and southerners than men and non-southerners. Total estimated national medical costs for MSDs within retail trade were $389 million (2007 USD).
Views of Health Information Management Staff on the Medical Coding Software in Mashhad, Iran.
Kimiafar, Khalil; Hemmati, Fatemeh; Banaye Yazdipour, Alireza; Sarbaz, Masoumeh
2018-01-01
Systematic evaluation of Health Information Technology (HIT) and users' views leads to the modification and development of these technologies in accordance with their needs. The purpose of this study was to investigate the views of Health Information Management (HIM) staff on the quality of medical coding software. A descriptive cross-sectional study was conducted between May to July 2016 in 26 hospitals (academic and non-academic) in Mashhad, north-eastern Iran. The study population consisted of the chairs of HIM departments and medical coders (58 staff). Data were collected through a valid and reliable questionnaire. The data were analyzed using the SPSS version 16.0. From the views of staff, the advantages of coding software such as reducing coding time had the highest average (Mean=3.82) while cost reduction had the lowest average (Mean =3.20), respectively. Meanwhile, concern about losing job opportunities was the least important disadvantage (15.5%) to the use of coding software. In general, the results of this study showed that coding software in some cases have deficiencies. Designers and developers of health information coding software should pay more attention to technical aspects, in-work reminders, help in deciding on proper codes selection by access coding rules, maintenance services, link to other relevant databases and the possibility of providing brief and detailed reports in different formats.
Codes of medical ethics: traditional foundations and contemporary practice.
Sohl, P; Bassford, H A
1986-01-01
The Hippocratic Coprus recognized the interaction of 'business' and patient-health moral considerations, and urged that the former be subordinated to the latter. During the 1800s with the growth of complexity in both scientific knowledge and the organization of health services, the medical ethical codes addressed themselves to elaborate rules of conduct to be followed by the members of the newly emerging national medical associations. After World War II the World Medical Association was established as an international forum where national medical associations could debate the ethical problems presented by modern medicine. The International Code of Medical ethics and the Declaration of Geneva were written as 20th century restatements of the medical profession's commitment to the sovereignty of the patient-care norm. Many ethical statements have been issued by the World Medical Association in the past 35 years; they show the variety and difficulties of contemporary medical practice. The newest revisions were approved by the General Assembly of the World Medical Association in Venice, Italy October 1983. Their content is examined and concern is voiced about the danger of falling into cultural relativism when questions about the methods of financing medical services are the subject of an ethical declaration which is arrived at by consensus in the W.M.A.
MEDICAL OPERATIONS IN DENIED ENVIRONMENTS (MODE): ARE OUR AF MEDICS READY
2016-02-28
modernization spending, more than the sum of the previous three administrations combined.16 Regional actors believe China’s increased A2/AD capabilities...requirements makes achieving the right personnel with sufficient medical readiness especially challenging.37 20 AF planners use unit type codes ... Codes (AFSCs) as a manpower-classification system to group together personnel that have similar duties, skills, and required training. The Air Force
NASA Technical Reports Server (NTRS)
Myhill, Elizabeth A.; Boss, Alan P.
1993-01-01
In Boss & Myhill (1992) we described the derivation and testing of a spherical coordinate-based scheme for solving the hydrodynamic equations governing the gravitational collapse of nonisothermal, nonmagnetic, inviscid, radiative, three-dimensional protostellar clouds. Here we discuss a Cartesian coordinate-based scheme based on the same set of hydrodynamic equations. As with the spherical coorrdinate-based code, the Cartesian coordinate-based scheme employs explicit Eulerian methods which are both spatially and temporally second-order accurate. We begin by describing the hydrodynamic equations in Cartesian coordinates and the numerical methods used in this particular code. Following Finn & Hawley (1989), we pay special attention to the proper implementations of high-order accuracy, finite difference methods. We evaluate the ability of the Cartesian scheme to handle shock propagation problems, and through convergence testing, we show that the code is indeed second-order accurate. To compare the Cartesian scheme discussed here with the spherical coordinate-based scheme discussed in Boss & Myhill (1992), the two codes are used to calculate the standard isothermal collapse test case described by Bodenheimer & Boss (1981). We find that with the improved codes, the intermediate bar-configuration found previously disappears, and the cloud fragments directly into a binary protostellar system. Finally, we present the results from both codes of a new test for nonisothermal protostellar collapse.
Kim, Dong-Sun; Kwon, Jin-San
2014-01-01
Research on real-time health systems have received great attention during recent years and the needs of high-quality personal multichannel medical signal compression for personal medical product applications are increasing. The international MPEG-4 audio lossless coding (ALS) standard supports a joint channel-coding scheme for improving compression performance of multichannel signals and it is very efficient compression method for multi-channel biosignals. However, the computational complexity of such a multichannel coding scheme is significantly greater than that of other lossless audio encoders. In this paper, we present a multichannel hardware encoder based on a low-complexity joint-coding technique and shared multiplier scheme for portable devices. A joint-coding decision method and a reference channel selection scheme are modified for a low-complexity joint coder. The proposed joint coding decision method determines the optimized joint-coding operation based on the relationship between the cross correlation of residual signals and the compression ratio. The reference channel selection is designed to select a channel for the entropy coding of the joint coding. The hardware encoder operates at a 40 MHz clock frequency and supports two-channel parallel encoding for the multichannel monitoring system. Experimental results show that the compression ratio increases by 0.06%, whereas the computational complexity decreases by 20.72% compared to the MPEG-4 ALS reference software encoder. In addition, the compression ratio increases by about 11.92%, compared to the single channel based bio-signal lossless data compressor. PMID:25237900
Standard terminology and labeling of ocular tissue for transplantation.
Armitage, W John; Ashford, Paul; Crow, Barbara; Dahl, Patricia; DeMatteo, Jennifer; Distler, Pat; Gopinathan, Usha; Madden, Peter W; Mannis, Mark J; Moffatt, S Louise; Ponzin, Diego; Tan, Donald
2013-06-01
To develop an internationally agreed terminology for describing ocular tissue grafts to improve the accuracy and reliability of information transfer, to enhance tissue traceability, and to facilitate the gathering of comparative global activity data, including denominator data for use in biovigilance analyses. ICCBBA, the international standards organization for terminology, coding, and labeling of blood, cells, and tissues, approached the major Eye Bank Associations to form an expert advisory group. The group met by regular conference calls to develop a standard terminology, which was released for public consultation and amended accordingly. The terminology uses broad definitions (Classes) with modifying characteristics (Attributes) to define each ocular tissue product. The terminology may be used within the ISBT 128 system to label tissue products with standardized bar codes enabling the electronic capture of critical data in the collection, processing, and distribution of tissues. Guidance on coding and labeling has also been developed. The development of a standard terminology for ocular tissue marks an important step for improving traceability and reducing the risk of mistakes due to transcription errors. ISBT 128 computer codes have been assigned and may now be used to label ocular tissues. Eye banks are encouraged to adopt this standard terminology and move toward full implementation of ISBT 128 nomenclature, coding, and labeling.
Certification of medical librarians, 1949--1977 statistical analysis.
Schmidt, D
1979-01-01
The Medical Library Association's Code for Training and Certification of Medical Librarians was in effect from 1949 to August 1977, a period during which 3,216 individuals were certified. Statistics on each type of certificate granted each year are provided. Because 54.5% of those granted certification were awarded it in the last three-year, two-month period of the code's existence, these applications are reviewed in greater detail. Statistics on each type of certificate granted each year are provided. Because 54.5% of those granted certification were awarded it in the last three-year, two-month period of the code's existence, these applications are reviewed in greater detail. Statistics on MLA membership, sex, residence, library school, and method of meeting requirements are detailed. Questions relating to certification under the code now in existence are raised.
Certification of medical librarians, 1949--1977 statistical analysis.
Schmidt, D
1979-01-01
The Medical Library Association's Code for Training and Certification of Medical Librarians was in effect from 1949 to August 1977, a period during which 3,216 individuals were certified. Statistics on each type of certificate granted each year are provided. Because 54.5% of those granted certification were awarded it in the last three-year, two-month period of the code's existence, these applications are reviewed in greater detail. Statistics on each type of certificate granted each year are provided. Because 54.5% of those granted certification were awarded it in the last three-year, two-month period of the code's existence, these applications are reviewed in greater detail. Statistics on MLA membership, sex, residence, library school, and method of meeting requirements are detailed. Questions relating to certification under the code now in existence are raised. PMID:427287
Simulation of Watts Bar Unit 1 Initial Startup Tests with Continuous Energy Monte Carlo Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Godfrey, Andrew T; Gehin, Jess C; Bekar, Kursat B
2014-01-01
The Consortium for Advanced Simulation of Light Water Reactors* is developing a collection of methods and software products known as VERA, the Virtual Environment for Reactor Applications. One component of the testing and validation plan for VERA is comparison of neutronics results to a set of continuous energy Monte Carlo solutions for a range of pressurized water reactor geometries using the SCALE component KENO-VI developed by Oak Ridge National Laboratory. Recent improvements in data, methods, and parallelism have enabled KENO, previously utilized predominately as a criticality safety code, to demonstrate excellent capability and performance for reactor physics applications. The highlymore » detailed and rigorous KENO solutions provide a reliable nu-meric reference for VERAneutronics and also demonstrate the most accurate predictions achievable by modeling and simulations tools for comparison to operating plant data. This paper demonstrates the performance of KENO-VI for the Watts Bar Unit 1 Cycle 1 zero power physics tests, including reactor criticality, control rod worths, and isothermal temperature coefficients.« less
The BaBar Data Reconstruction Control System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ceseracciu, A
2005-04-20
The BaBar experiment is characterized by extremely high luminosity and very large volume of data produced and stored, with increasing computing requirements each year. To fulfill these requirements a Control System has been designed and developed for the offline distributed data reconstruction system. The control system described in this paper provides the performance and flexibility needed to manage a large number of small computing farms, and takes full benefit of OO design. The infrastructure is well isolated from the processing layer, it is generic and flexible, based on a light framework providing message passing and cooperative multitasking. The system ismore » distributed in a hierarchical way: the top-level system is organized in farms, farms in services, and services in subservices or code modules. It provides a powerful Finite State Machine framework to describe custom processing models in a simple regular language. This paper describes the design and evolution of this control system, currently in use at SLAC and Padova on {approx}450 CPUs organized in 9 farms.« less
The BaBar Data Reconstruction Control System
NASA Astrophysics Data System (ADS)
Ceseracciu, A.; Piemontese, M.; Tehrani, F. S.; Pulliam, T. M.; Galeazzi, F.
2005-08-01
The BaBar experiment is characterized by extremely high luminosity and very large volume of data produced and stored, with increasing computing requirements each year. To fulfill these requirements a control system has been designed and developed for the offline distributed data reconstruction system. The control system described in this paper provides the performance and flexibility needed to manage a large number of small computing farms, and takes full benefit of object oriented (OO) design. The infrastructure is well isolated from the processing layer, it is generic and flexible, based on a light framework providing message passing and cooperative multitasking. The system is distributed in a hierarchical way: the top-level system is organized in farms, farms in services, and services in subservices or code modules. It provides a powerful finite state machine framework to describe custom processing models in a simple regular language. This paper describes the design and evolution of this control system, currently in use at SLAC and Padova on /spl sim/450 CPUs organized in nine farms.
Investigating the use of quick response codes in the gross anatomy laboratory.
Traser, Courtney J; Hoffman, Leslie A; Seifert, Mark F; Wilson, Adam B
2015-01-01
The use of quick response (QR) codes within undergraduate university courses is on the rise, yet literature concerning their use in medical education is scant. This study examined student perceptions on the usefulness of QR codes as learning aids in a medical gross anatomy course, statistically analyzed whether this learning aid impacted student performance, and evaluated whether performance could be explained by the frequency of QR code usage. Question prompts and QR codes tagged on cadaveric specimens and models were available for four weeks as learning aids to medical (n = 155) and doctor of physical therapy (n = 39) students. Each QR code provided answers to posed questions in the form of embedded text or hyperlinked web pages. Students' perceptions were gathered using a formative questionnaire and practical examination scores were used to assess potential gains in student achievement. Overall, students responded positively to the use of QR codes in the gross anatomy laboratory as 89% (57/64) agreed the codes augmented their learning of anatomy. The users' most noticeable objection to using QR codes was the reluctance to bring their smartphones into the gross anatomy laboratory. A comparison between the performance of QR code users and non-users was found to be nonsignificant (P = 0.113), and no significant gains in performance (P = 0.302) were observed after the intervention. Learners welcomed the implementation of QR code technology in the gross anatomy laboratory, yet this intervention had no apparent effect on practical examination performance. © 2014 American Association of Anatomists.
Erickson, Steven R; Workman, Paul
2014-01-01
To document the availability of selected pharmacy services and out-of-pocket cost of medication throughout a diverse county in Michigan and to assess possible associations between availability of services and price of medication and characteristics of residents of the ZIP codes in which the pharmacies were located. Cross-sectional telephone survey of pharmacies coupled with ZIP code-level census data. 503 pharmacies throughout the 63 ZIP codes of Wayne County, MI. The out-of-pocket cost for a 30 days' supply of levothyroxine 50 mcg and brand-name atorvastatin (Lipitor-Pfizer) 20 mg, availability of discount generic drug programs, home delivery of medications, hours of pharmacy operation, and availability of pharmacy-based immunization services. Census data aggregated at the ZIP code level included race, annual household income, age, and number of residents per pharmacy. The overall results per ZIP code showed that the average cost for levothyroxine was $10.01 ± $2.29 and $140.45 + $14.70 for Lipitor. Per ZIP code, the mean (± SD) percentages of pharmacies offering discount generic drug programs was 66.9% ± 15.0%; home delivery of medications was 44.5% ± 22.7%; and immunization for influenza was 46.7% ± 24.3% of pharmacies. The mean (± SD) hours of operation per pharmacy per ZIP code was 67.0 ± 25.2. ZIP codes with higher household income as well as higher percentage of residents being white had lower levothyroxine price, greater percentage of pharmacies offering discount generic drug programs, more hours of operation per week, and more pharmacy-based immunization services. The cost of Lipitor was not associated with any ZIP code characteristic. Disparities in the cost of generic levothyroxine, the availability of services such as discount generic drug programs, hours of operation, and pharmacy-based immunization services are evident based on race and household income within this diverse metropolitan county.
Protein supplementation with sports protein bars in renal patients.
Meade, Anthony
2007-05-01
Malnutrition prevalence in patients on dialysis is well established. The protein requirements for both hemodialysis and peritoneal dialysis have been documented elsewhere, including the Kidney Disease Outcomes Quality Initiative Clinical Practice Guidelines for Nutrition in Chronic Renal Failure. The clinical challenge is to assist patients in meeting these targets, especially in those with anorexia. Traditional supplements have included fluid, which is an issue for patients who are fluid restricted. The study objectives were to (1) investigate the range of sports protein supplements that may be suitable for patients on hemodialysis to use and (2) trial nonfluid protein supplements in patients on hemodialysis. Known manufacturers of sports protein bars and other sports supplements available in Australia were contacted for the nutrient breakdown of high-protein products, specifically potassium, protein, and phosphorus contents. As a result, selected high-protein sports bars (Protein FX, Aussie Bodies, Port Melbourne, Victoria, Australia) were used as an alternative to the more commonly used renal-specific fluid supplements (Nepro, Abbott Laboratories, Abbott Park, IL; Novasource Renal, Novartis Nutrition Corporation, Fremont, MI; and Renilon, Nutricia, Wiltshire, UK) in patients with poor nutritional status requiring supplementation. Patient satisfaction and clinical nutrition markers were investigated. The study took place at inpatient, in-center, and satellite hemodialysis settings in Adelaide, South Australia. A total of 32 patients (16 females and 16 males) with an average age of 62.9 years (range 32-86 years) undergoing hemodialysis (acute and maintenance) were included. Subjects were selected by the author as part of routine clinical nutrition care. Patients trialed sports protein bars as a protein supplement alone or in conjunction with other supplementary products. All patients were in favor of the trial, with 22 of 32 patients continuing with the protein bars as the preferred supplement. The major reasons for not continuing were taste and chewability, especially in older patients with dentures. Serum potassium and phosphate levels were not increased with supplementation. Measured serum albumin and protein catabolic rate were considered unreliable indicators because not all patients were medically stable. Sports protein bars are an acceptable protein and energy supplement for patients on hemodialysis. Sports protein bars are well accepted by patients except when dentures limit chewability. Sports protein bars have advantages over fluid-based supplements in patients with fluid restrictions.
[Pressure control in medical gas distribution systems].
Bourgain, J L; Benayoun, L; Baguenard, P; Haré, G; Puizillout, J M; Billard, V
1997-01-01
To assess whether the pressure gauges at the downstream part of pressure regulators are accurate enough to ensure that pressure in O2 pipeline is always higher than in Air pipeline and that pressure in the latter is higher than pressure in N2O pipeline. A pressure difference of at least 0.4 bar between two medical gas supply systems is recommended to avoid the reflow of either N2O or Air into the O2 pipeline, through a faulty mixer or proportioning device. Prospective technical comparative study. Readings of 32 Bourdon gauges were compared with data obtained with a calibrated reference transducer. Two sets of measurements were performed at a one month interval. Pressure differences between Bourdon gauges and reference transducer were 8% (0.28 bar) in average for a theoretical maximal error less than 2.5%. During the first set of measurements, Air pressure was higher than O2 pressure in one place and N2O pressure higher than Air pressure in another. After an increase in the O2 pipeline pressure and careful setting of pressure regulators, this problem was not observed at the second set of measurements. Actual accuracy of Bourdon gauges was not convenient enough to ensure that O2 pressure was always above Air pressure. Regular controls of these pressure gauges are therefore essential. Replacement of the faulty Bourdon gauges by more accurate transducers should be considered. As an alternative, the increase in pressure difference between O2 and Air pipelines to at least 0.6 bar is recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osthus, Dave; Godinez, Humberto C.; Rougier, Esteban
We presenmore » t a generic method for automatically calibrating a computer code to an experiment, with uncertainty, for a given “training” set of computer code runs. The calibration technique is general and probabilistic, meaning the calibration uncertainty is represented in the form of a probability distribution. We demonstrate the calibration method by calibrating a combined Finite-Discrete Element Method (FDEM) to a Split Hopkinson Pressure Bar (SHPB) experiment with a granite sample. The probabilistic calibration method combines runs of a FDEM computer simulation for a range of “training” settings and experimental uncertainty to develop a statistical emulator. The process allows for calibration of input parameters and produces output quantities with uncertainty estimates for settings where simulation results are desired. Input calibration and FDEM fitted results are presented. We find that the maximum shear strength σ t max and to a lesser extent maximum tensile strength σ n max govern the behavior of the stress-time curve before and around the peak, while the specific energy in Mode II (shear) E t largely governs the post-peak behavior of the stress-time curve. Good agreement is found between the calibrated FDEM and the SHPB experiment. Interestingly, we find the SHPB experiment to be rather uninformative for calibrating the softening-curve shape parameters (a, b, and c). This work stands as a successful demonstration of how a general probabilistic calibration framework can automatically calibrate FDEM parameters to an experiment.« less
Osthus, Dave; Godinez, Humberto C.; Rougier, Esteban; ...
2018-05-01
We presenmore » t a generic method for automatically calibrating a computer code to an experiment, with uncertainty, for a given “training” set of computer code runs. The calibration technique is general and probabilistic, meaning the calibration uncertainty is represented in the form of a probability distribution. We demonstrate the calibration method by calibrating a combined Finite-Discrete Element Method (FDEM) to a Split Hopkinson Pressure Bar (SHPB) experiment with a granite sample. The probabilistic calibration method combines runs of a FDEM computer simulation for a range of “training” settings and experimental uncertainty to develop a statistical emulator. The process allows for calibration of input parameters and produces output quantities with uncertainty estimates for settings where simulation results are desired. Input calibration and FDEM fitted results are presented. We find that the maximum shear strength σ t max and to a lesser extent maximum tensile strength σ n max govern the behavior of the stress-time curve before and around the peak, while the specific energy in Mode II (shear) E t largely governs the post-peak behavior of the stress-time curve. Good agreement is found between the calibrated FDEM and the SHPB experiment. Interestingly, we find the SHPB experiment to be rather uninformative for calibrating the softening-curve shape parameters (a, b, and c). This work stands as a successful demonstration of how a general probabilistic calibration framework can automatically calibrate FDEM parameters to an experiment.« less
Passive sampling methods to determine household and personal care product use.
Bennett, Deborah H; Wu, Xiangmei May; Teague, Candice H; Lee, Kiyoung; Cassady, Diana L; Ritz, Beate; Hertz-Picciotto, Irva
2012-01-01
Traditionally, use of household and personal care products has been collected through questionnaires, which is very time consuming, a burden on participants, and prone to recall bias. As part of the SUPERB Project (Study of Use of Products and Exposure-Related Behaviors), a novel platform was developed using bar codes to quickly and reliably determine what household and personal care products people have in their homes and determine the amount used over a 1-week period. We evaluated the acceptability and feasibility of our methodology in a longitudinal field study that included 47 California households, 30 with young children and 17 with an older adult. Acceptability was defined by refusal rates; feasibility was evaluated in terms of readable bar codes, useful product information in our database for all readable barcodes, and ability to find containers at both the start and end of the week. We found 63% of personal care products and 87% of the household care products had readable barcodes with 47% and 41% having sufficient data for product identification, respectively and secondly, the amount used could be determined most of the time. We present distributions for amount used by product category and compare inter- and intra-person variability. In summary, our method appears to be appropriate, acceptable, and useful for gathering information related to potential exposures stemming from the use of personal and household care products. A very low drop-out rate suggests that this methodology can be useful in longitudinal studies of exposure to household and personal care products.
Cyanobacterial distributions along a physico-chemical gradient in the Northeastern Pacific Ocean.
Sudek, Sebastian; Everroad, R Craig; Gehman, Alyssa-Lois M; Smith, Jason M; Poirier, Camille L; Chavez, Francisco P; Worden, Alexandra Z
2015-10-01
The cyanobacteria Prochlorococcus and Synechococcus are important marine primary producers. We explored their distributions and covariance along a physico-chemical gradient from coastal to open ocean waters in the Northeastern Pacific Ocean. An inter-annual pattern was delineated in the dynamic transition zone where upwelled and eastern boundary current waters mix, and two new Synechococcus clades, Eastern Pacific Clade (EPC) 1 and EPC2, were identified. By applying state-of-the-art phylogenetic analysis tools to bar-coded 16S amplicon datasets, we observed higher abundance of Prochlorococcus high-light I (HLI) and low-light I (LLI) in years when more oligotrophic water intruded farther inshore, while under stronger upwelling Synechococcus I and IV dominated. However, contributions of some cyanobacterial clades were proportionally relatively constant, e.g. Synechococcus EPC2. In addition to supporting observations that Prochlorococcus LLI thrive at higher irradiances than other LL taxa, the results suggest LLI tolerate lower temperatures than previously reported. The phylogenetic precision of our 16S rRNA gene analytical approach and depth of bar-coded sequencing also facilitated detection of clades at low abundance in unexpected places. These include Prochlorococcus at the coast and Cyanobium-related sequences offshore, although it remains unclear whether these came from resident or potentially advected cells. Our study enhances understanding of cyanobacterial distributions in an ecologically important eastern boundary system. © 2014 The Authors. Environmental Microbiology published by Society for Applied Microbiology and John Wiley & Sons Ltd.
Studying Functions of All Yeast Genes Simultaneously
NASA Technical Reports Server (NTRS)
Stolc, Viktor; Eason, Robert G.; Poumand, Nader; Herman, Zelek S.; Davis, Ronald W.; Anthony Kevin; Jejelowo, Olufisayo
2006-01-01
A method of studying the functions of all the genes of a given species of microorganism simultaneously has been developed in experiments on Saccharomyces cerevisiae (commonly known as baker's or brewer's yeast). It is already known that many yeast genes perform functions similar to those of corresponding human genes; therefore, by facilitating understanding of yeast genes, the method may ultimately also contribute to the knowledge needed to treat some diseases in humans. Because of the complexity of the method and the highly specialized nature of the underlying knowledge, it is possible to give only a brief and sketchy summary here. The method involves the use of unique synthetic deoxyribonucleic acid (DNA) sequences that are denoted as DNA bar codes because of their utility as molecular labels. The method also involves the disruption of gene functions through deletion of genes. Saccharomyces cerevisiae is a particularly powerful experimental system in that multiple deletion strains easily can be pooled for parallel growth assays. Individual deletion strains recently have been created for 5,918 open reading frames, representing nearly all of the estimated 6,000 genetic loci of Saccharomyces cerevisiae. Tagging of each deletion strain with one or two unique 20-nucleotide sequences enables identification of genes affected by specific growth conditions, without prior knowledge of gene functions. Hybridization of bar-code DNA to oligonucleotide arrays can be used to measure the growth rate of each strain over several cell-division generations. The growth rate thus measured serves as an index of the fitness of the strain.
San, Tay Hui; Lin, Serena Koh Siew; Fai, Chan Moon
Information technology to aid reduction in medication errors has been encouraged over the years and one of them is the medication administration technology. It consists of the electronic Medication Administration Record, Bar-Code Medication Administration system and Automated Medication Dispensing system. Studies had examined the effectiveness and impact of this technology to reduce medication error. However, user's acceptance towards this technology has often been neglected. To date, no systematic review has been undertaken to examine the possible factors that affect nurses' use of this technology in the acute care settings. The objective of this systematic review was to explore and determine the factors that affect nurses' use of medication administration technology in the acute care settings. All quantitative studies published in English which examined factors affecting nurses' use of the medication administration technology were considered.Primary focus was on registered nurses with experience of operating medication administration technology in the acute care settings. Other healthcare personnel were excluded.This review considered studies that evaluated factors affecting nurses' use of the medication administration technology.The outcome measures of interest were the factors that affect nurses' use of the medication administration technology in the acute care settings. The search was conducted across published and unpublished databases. A search was conducted in JBI Library of Systematic Reviews, The Cochrane Library, CINAHL, MEDLINE, Scopus, ScienceDirect, Wiley InterScience, SpringerLink, PsycINFO (ovid), Web of science, ProQuest Dissertations and Theses, and MedNar. Papers selected for retrieval were assessed by two independent reviewers for methodological validity prior to inclusion in the review, using the standardised critical appraisal instruments developed by the Joanna Briggs Institute. Quantitative data were extracted from papers included in the review using a standardised data extraction tool developed by the JBI. Findings were presented in narrative summary due to heterogeneity of the study designs. Six descriptive studies were included in this review. Nurses' use of the technology can be influenced by a combination of complex and inter-related factors, such as organisational factors, and user and system characteristics. In order to successfully implement medication administration technology, system, user and organisational factors have to be collaborated concurrently.Users' needs should be accommodated when designing the system features. Prior to system implementation, institutions should consider the users' demographical characteristics and provide adequate preparations and training. A supportive culture from the institution and colleagues is also important.There is a significant need for further research in this field. Further research to discover potential factors in different settings, locations and countries are suggested. Studies to evaluate nurses' use of the technology at regular intervals are also required.
A survey to identify the clinical coding and classification systems currently in use across Europe.
de Lusignan, S; Minmagh, C; Kennedy, J; Zeimet, M; Bommezijn, H; Bryant, J
2001-01-01
This is a survey to identify what clinical coding systems are currently in use across the European Union, and the states seeking membership to it. We sought to identify what systems are currently used and to what extent they were subject to local adaptation. Clinical coding should facilitate identifying key medical events in a computerised medical record, and aggregating information across groups of records. The emerging new driver is as the enabler of the life-long computerised medical record. A prerequisite for this level of functionality is the transfer of information between different computer systems. This transfer can be facilitated either by working on the interoperability problems between disparate systems or by harmonising the underlying data. This paper examines the extent to which the latter has occurred across Europe. Literature and Internet search. Requests for information via electronic mail to pan-European mailing lists of health informatics professionals. Coding systems are now a de facto part of health information systems across Europe. There are relatively few coding systems in existence across Europe. ICD9 and ICD 10, ICPC and Read were the most established. However the local adaptation of these classification systems either on a by country or by computer software manufacturer basis; significantly reduces the ability for the meaning coded with patients computer records to be easily transferred from one medical record system to another. There is no longer any debate as to whether a coding or classification system should be used. Convergence of different classifications systems should be encouraged. Countries and computer manufacturers within the EU should be encouraged to stop making local modifications to coding and classification systems, as this practice risks significantly slowing progress towards easy transfer of records between computer systems.
Medical ethics and education for social responsibility.
Roemer, M I
1980-01-01
The physician, said Henry Sigerist in 1940, has been acquiring an increasingly social role. For centuries, however, codes of medical ethics have concentrated on proper behavior toward individual patients and almost ignored the doctor's responsibilities to society. Major health service reforms have come principally from motivated lay leadership and citizen groups. Private physicians have been largely hostile toward movements to equalize the economic access for people to medical care and improve the supply and distribution of doctors. Medical practice in America and throughout the world has become seriously commercialized. In response, governments have applied various strategies to constrain physicians and induce more socially responsible behavior. But such external pressures should not be necessary if a broad socially oriented code of medical ethics were followed. Health care system changes would be most effective, but medical education could be thoroughly recast to clarify community health problems and policies required to meet them. Sigerist proposed such a new medical curriculum in 1941; if it had been introduced, a social code of medical ethics would not now seem utopian. An international conference might well be convened to consider how physicians should be educated to reach the inspiring goals of the World Health Organization.
Medical ethics and education for social responsibility.
Roemer, M. I.
1980-01-01
The physician, said Henry Sigerist in 1940, has been acquiring an increasingly social role. For centuries, however, codes of medical ethics have concentrated on proper behavior toward individual patients and almost ignored the doctor's responsibilities to society. Major health service reforms have come principally from motivated lay leadership and citizen groups. Private physicians have been largely hostile toward movements to equalize the economic access for people to medical care and improve the supply and distribution of doctors. Medical practice in America and throughout the world has become seriously commercialized. In response, governments have applied various strategies to constrain physicians and induce more socially responsible behavior. But such external pressures should not be necessary if a broad socially oriented code of medical ethics were followed. Health care system changes would be most effective, but medical education could be thoroughly recast to clarify community health problems and policies required to meet them. Sigerist proposed such a new medical curriculum in 1941; if it had been introduced, a social code of medical ethics would not now seem utopian. An international conference might well be convened to consider how physicians should be educated to reach the inspiring goals of the World Health Organization. PMID:7405276
EvoluCode: Evolutionary Barcodes as a Unifying Framework for Multilevel Evolutionary Data.
Linard, Benjamin; Nguyen, Ngoc Hoan; Prosdocimi, Francisco; Poch, Olivier; Thompson, Julie D
2012-01-01
Evolutionary systems biology aims to uncover the general trends and principles governing the evolution of biological networks. An essential part of this process is the reconstruction and analysis of the evolutionary histories of these complex, dynamic networks. Unfortunately, the methodologies for representing and exploiting such complex evolutionary histories in large scale studies are currently limited. Here, we propose a new formalism, called EvoluCode (Evolutionary barCode), which allows the integration of different evolutionary parameters (eg, sequence conservation, orthology, synteny …) in a unifying format and facilitates the multilevel analysis and visualization of complex evolutionary histories at the genome scale. The advantages of the approach are demonstrated by constructing barcodes representing the evolution of the complete human proteome. Two large-scale studies are then described: (i) the mapping and visualization of the barcodes on the human chromosomes and (ii) automatic clustering of the barcodes to highlight protein subsets sharing similar evolutionary histories and their functional analysis. The methodologies developed here open the way to the efficient application of other data mining and knowledge extraction techniques in evolutionary systems biology studies. A database containing all EvoluCode data is available at: http://lbgi.igbmc.fr/barcodes.
ERIC Educational Resources Information Center
Morris, Suzanne E.
2010-01-01
This paper provides a review of institutional authorship policies as required by the "Australian Code for the Responsible Conduct of Research" (the "Code") (National Health and Medical Research Council (NHMRC), the Australian Research Council (ARC) & Universities Australia (UA) 2007), and assesses them for Code compliance.…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-28
... . You can search for the document by entering ``Public Notice '' in the Search bar. If necessary, use... the time and cost burden for this proposed collection, including the validity of the methodology and.... Methodology: The Bureau of Consular Affairs will be posting this form on Department of State Web sites to give...
The bar-halo interaction - I. From fundamental dynamics to revised N-body requirements
NASA Astrophysics Data System (ADS)
Weinberg, Martin D.; Katz, Neal
2007-02-01
A galaxy remains near equilibrium for most of its history. Only through resonances can non-axisymmetric features, such as spiral arms and bars, exert torques over large scales and change the overall structure of the galaxy. In this paper, we describe the resonant interaction mechanism in detail, derive explicit criteria for the particle number required to simulate these dynamical processes accurately using N-body simulations, and illustrate them with numerical experiments. To do this, we perform a direct numerical solution of perturbation theory, in short, by solving for each orbit in an ensemble and make detailed comparisons with N-body simulations. The criteria include: sufficient particle coverage in phase space near the resonance and enough particles to minimize gravitational potential fluctuations that will change the dynamics of the resonant encounter. These criteria are general in concept and can be applied to any dynamical interaction. We use the bar-halo interaction as our primary example owing to its technical simplicity and astronomical ubiquity. Some of our more surprising findings are as follows. First, the inner Lindblad like resonance, responsible for coupling the bar to the central halo cusp, requires more than equal-mass particles within the virial radius or inside the bar radius for a Milky Way like bar in a Navarro, Frenk & White profile. Secondly, orbits that linger near the resonance receive more angular momentum than orbits that move through the resonance quickly. Small-scale fluctuations present in state-of-the-art particle-particle simulations can knock orbits out of resonance, preventing them from lingering and, thereby, decrease the torque per orbit. This can be offset by the larger number of orbits affected by the resonance due to the diffusion. However, noise from orbiting substructure remains at least an order of magnitude too small to be of consequence. Applied to N-body simulations, the required particle numbers are sufficiently high for scenarios of interest that apparent convergence in particle number is misleading: the convergence with N may still be in the noise-dominated regime. State-of-the-art simulations are not adequate to follow all aspects of secular evolution driven by the bar-halo interaction. It is not possible to derive particle number requirements that apply to all situations, for example, more subtle interactions may be even more difficult to simulate. Therefore, we present a procedure to test the requirements for individual N-body codes to the actual problem of interest.
Compressed Air Working in Chennai During Metro Tunnel Construction: Occupational Health Problems
Kulkarni, Ajit C.
2017-01-01
Chennai metropolis has been growing rapidly. Need was felt of a metro rail system. Two corridors were planned. Corridor 1, of 23 km starting from Washermanpet to Airport. 14.3 km of this would be underground. Corridor 2, of 22 km starting from Chennai Central Railway station to St. Thomas Mount. 9.7 km of this would be underground. Occupational health centre's role involved selection of miners and assessing their fitness to work under compressed air. Planning and execution of compression and decompression, health monitoring and treatment of compression related illnesses. More than thirty five thousand man hours of work was carried out under compressed air pressure ranged from 1.2 to 1.9 bar absolute. There were only three cases of pain only ( Type I) decompression sickness which were treated with recompression. Vigilant medical supervision, experienced lock operators and reduced working hours under pressure because of inclement environmental conditions viz. high temperature and humidity, has helped achieve this low incident. Tunnelling activity will increase in India as more cities will soon opt for underground metro railway. Indian standard IS 4138 – 1977 ” Safety code for working in compressed air” needs to be updated urgently keeping pace with modern working methods. PMID:29618908
Lindgren, Carolyn L; Elie, Leslie G; Vidal, Elizabeth C; Vasserman, Alex
2010-01-01
In reaching the goal for standardized, quality care, a not-for-profit healthcare system consisting of seven institutional entities is transforming nursing practice guidelines, patient care workflow, and patient documents into electronic, online, real-time modalities for use across departments and all healthcare delivery entities of the system. Organizational structure and a strategic plan were developed for the 2-year Clinical Transformation Project. The Siemens Patient Care Document System was adopted and adapted to the hospitals' documentation and information needs. Two fast-track sessions of more than 100 nurses and representatives from other health disciplines were held to standardize assessments, histories, care protocols, and interdisciplinary plans of care for the top 10 diagnostic regulatory groups. Education needs of the users were addressed. After the first year, a productive, functional system is evidenced. For example, the bar-coded Medication Administration Check System is in full use on the clinical units of one of the hospitals, and the other institutional entities are at substantial stages of implementation of Patient Care Documentation System. The project requires significant allocation of personnel and financial resources for a highly functional informatics system that will transform clinical care. The project exemplifies four of the Magnet ideals and serves as a model for others who may be deciding about launching a similar endeavor.
The Nuremberg Code and the Nuremberg Trial. A reappraisal.
Katz, J
1996-11-27
The Nuremberg Code includes 10 principles to guide physician-investigators in experiments involving human subjects. These principles, particularly the first principle on "voluntary consent," primarily were based on legal concepts because medical codes of ethics existent at the time of the Nazi atrocities did not address consent and other safeguards for human subjects. The US judges who presided over the proceedings did not intend the Code to apply only to the case before them, to be a response to the atrocities committed by the Nazi physicians, or to be inapplicable to research as it is customarily carried on in medical institutions. Instead, a careful reading of the judgment suggests that they wrote the Code for the practice of human experimentation whenever it is being conducted.
Faden, R R; Lederer, S E; Moreno, J D
1996-11-27
The Advisory Committee on Human Radiation Experiments (ACHRE), established to review allegations of abuses of human subjects in federally sponsored radiation research, was charged with identifying appropriate standards to evaluate the ethics of cold war radiation experiments. One central question for ACHRE was to determine what role, if any, the Nuremberg Code played in the norms and practices of US medical researchers. Based on the evidence from ACHRE's Ethics Oral History Project and extensive archival research, we conclude that the Code, at the time it was promulgated, had little effect on mainstream medical researchers engaged in human subjects research. Although some clinical investigators raised questions about the conduct of research involving human beings, the medical profession did not pursue this issue until the 1960s.
Sato, Tatsuhiko; Furuta, Takuya; Hashimoto, Shintaro; Kuga, Naoya
2015-01-01
PHITS is a general purpose Monte Carlo particle transport simulation code developed through the collaboration of several institutes mainly in Japan. It can analyze the motion of nearly all radiations over wide energy ranges in 3-dimensional matters. It has been used for various applications including medical physics. This paper reviews the recent improvements of the code, together with the biological dose estimation method developed on the basis of the microdosimetric function implemented in PHITS.
2012-11-01
causes of hypertension ") AND NOT(report_text:"pulmonary| portal hypertension " OR report_text:"secondary to hypertension ") 182 Patients with Ischemic... hypertension , and tachycardia (discharge_icd_codes_txt:293.0 OR report_text:delirium) AND (discharge_icd_codes_txt:401.* OR discharge_icd_codes_txt:405...report_text:"**AGE[in teens") 162 Patients with hypertension on anti- hypertensive medication (report_text:" hypertension " OR report_text:"high blood
Current issues in billing and coding in interventional pain medicine.
Manchikanti, L
2000-10-01
Interventional pain management is a dynamic field with changes occurring on a daily basis, not only with technology but also with regulations that have a substantial financial impact on practices. Regulations are imposed not only by the federal government and other regulatory agencies, and also by a multitude of other payors, state governments and medical boards. Documentation of medical necessity with coding that correlates with multiple components of the patient's medical record, operative report, and billing statement is extremely important. Numerous changes which have occurred in the practice of interventional pain management in the new millennium continue to impact the financial viability of interventional pain practices along with patient access to these services. Thus, while complying with regulations of billing, coding and proper, effective, and ethical practice of pain management, it is also essential for physicians to understand financial aspects and the impact of various practice patterns. This article provides guidelines which are meant to provide practical considerations for billing and coding of interventional techniques in the management of chronic pain based on the current state of the art and science of interventional pain management. Hence, these guidelines do not constitute inflexible treatment, coding, billing or documentation recommendations. It is expected that a provider will establish a plan of care on a case-by-case basis taking into account an individual patient's medical condition, personal needs, and preferences, along with physician's experience and in a similar manner, billing and coding practices will be developed. Based on an individual patient's needs, treatment, billing and coding, different from what is outlined here is not only warranted but essential.
nIFTY galaxy cluster simulations - III. The similarity and diversity of galaxies and subhaloes
NASA Astrophysics Data System (ADS)
Elahi, Pascal J.; Knebe, Alexander; Pearce, Frazer R.; Power, Chris; Yepes, Gustavo; Cui, Weiguang; Cunnama, Daniel; Kay, Scott T.; Sembolini, Federico; Beck, Alexander M.; Davé, Romeel; February, Sean; Huang, Shuiyao; Katz, Neal; McCarthy, Ian G.; Murante, Giuseppe; Perret, Valentin; Puchwein, Ewald; Saro, Alexandro; Teyssier, Romain
2016-05-01
We examine subhaloes and galaxies residing in a simulated Λ cold dark matter galaxy cluster (M^crit_{200}=1.1× 10^{15} h^{-1} M_{⊙}) produced by hydrodynamical codes ranging from classic smooth particle hydrodynamics (SPH), newer SPH codes, adaptive and moving mesh codes. These codes use subgrid models to capture galaxy formation physics. We compare how well these codes reproduce the same subhaloes/galaxies in gravity-only, non-radiative hydrodynamics and full feedback physics runs by looking at the overall subhalo/galaxy distribution and on an individual object basis. We find that the subhalo population is reproduced to within ≲10 per cent for both dark matter only and non-radiative runs, with individual objects showing code-to-code scatter of ≲0.1 dex, although the gas in non-radiative simulations shows significant scatter. Including feedback physics significantly increases the diversity. Subhalo mass and Vmax distributions vary by ≈20 per cent. The galaxy populations also show striking code-to-code variations. Although the Tully-Fisher relation is similar in almost all codes, the number of galaxies with 109 h- 1 M⊙ ≲ M* ≲ 1012 h- 1 M⊙ can differ by a factor of 4. Individual galaxies show code-to-code scatter of ˜0.5 dex in stellar mass. Moreover, systematic differences exist, with some codes producing galaxies 70 per cent smaller than others. The diversity partially arises from the inclusion/absence of active galactic nucleus feedback. Our results combined with our companion papers demonstrate that subgrid physics is not just subject to fine-tuning, but the complexity of building galaxies in all environments remains a challenge. We argue that even basic galaxy properties, such as stellar mass to halo mass, should be treated with errors bars of ˜0.2-0.4 dex.
Design of monitoring system for mail-sorting based on the Profibus S7 series PLC
NASA Astrophysics Data System (ADS)
Zhang, W.; Jia, S. H.; Wang, Y. H.; Liu, H.; Tang, G. C.
2017-01-01
With the rapid development of the postal express, the workload of mail sorting is increasing, but the automatic technology of mail sorting is not mature enough. In view of this, the system uses Siemens S7-300 PLC as the main station controller, PLC of Siemens S7-200/400 is from the station controller, through the man-machine interface configuration software MCGS, PROFIBUS-DP communication, RFID technology and mechanical sorting hand achieve mail classification sorting monitoring. Among them, distinguish mail-sorting by scanning RFID posted in the mail electronic bar code (fixed code), the system uses the corresponding controller on the acquisition of information processing, the processed information transmit to the sorting manipulator by PROFIBUS-DP. The system can realize accurate and efficient mail sorting, which will promote the development of mail sorting technology.
Money, Nicholas P
2013-01-01
The use of molecular bar-coding and consensus on nomenclatural practices has encouraged optimism about the future of fungal taxonomy and systematics. There are, however, profound deficiencies in our understanding of fungal diversity and broader problems with the taxonomic enterprise that deserve greater attention. For 250 years mycologists have tried to reconcile fungal diversity with the Linnean fantasy of a divine order throughout nature that included unambiguous species. This effort has failed and today's taxonomy rests on an unstable philosophical foundation. Rather than persisting with the present endeavour, it may be more fruitful to abandon the notion of fungal species pending further basic research. In the meantime, mycologists should consider tagging collections with digital codes and assigning these operational taxonomic units to higher taxonomic ranks whose objective reality is corroborated by strong phylogenetic evidence. Copyright © 2013 The Author. Published by Elsevier Ltd.. All rights reserved.
Triaxial instabilities in rapidly rotating neutron stars
NASA Astrophysics Data System (ADS)
Basak, Arkadip
2018-06-01
Viscosity driven bar mode secular instabilities of rapidly rotating neutron stars are studied using LORENE/Nrotstar code. These instabilities set a more rigorous limit to the rotation frequency of a neutron star than the Kepler frequency/mass-shedding limit. The procedure employed in the code comprises of perturbing an axisymmetric and stationary configuration of a neutron star and studying its evolution by constructing a series of triaxial quasi-equilibrium configurations. Symmetry breaking point was found out for Polytropic as well as 10 realistic equations of states (EOS) from the CompOSE data base. The concept of piecewise polytropic EOSs has been used to comprehend the rotational instability of Realistic EOSs and validated with 19 different Realistic EOSs from CompOSE. The possibility of detecting quasi-periodic gravitational waves from viscosity driven instability with ground-based LIGO/VIRGO interferometers is also discussed very briefly.
Preliminary Development of an Object-Oriented Optimization Tool
NASA Technical Reports Server (NTRS)
Pak, Chan-gi
2011-01-01
The National Aeronautics and Space Administration Dryden Flight Research Center has developed a FORTRAN-based object-oriented optimization (O3) tool that leverages existing tools and practices and allows easy integration and adoption of new state-of-the-art software. The object-oriented framework can integrate the analysis codes for multiple disciplines, as opposed to relying on one code to perform analysis for all disciplines. Optimization can thus take place within each discipline module, or in a loop between the central executive module and the discipline modules, or both. Six sample optimization problems are presented. The first four sample problems are based on simple mathematical equations; the fifth and sixth problems consider a three-bar truss, which is a classical example in structural synthesis. Instructions for preparing input data for the O3 tool are presented.
78 FR 72576 - Criteria for a Catastrophically Disabled Determination for Purposes of Enrollment
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-03
... Procedural Terminology (CPT[supreg]) codes. The revisions ensure that the regulation is not out of date when... trademark of the American Medical Association. CPT codes and descriptions are copyrighted by the American Medical Association. All rights reserved.) This approach will soon be outdated; the ICD-9-CM and CPT...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-15
... Administrator among the fields of hospital payment systems; hospital medical care delivery systems; provider billing and accounting systems; APC groups; Current Procedural Terminology codes; HCPCS codes; the use of, and payment for, drugs, medical devices, and other services in the outpatient setting; and other forms...
Joint sparse coding based spatial pyramid matching for classification of color medical image.
Shi, Jun; Li, Yi; Zhu, Jie; Sun, Haojie; Cai, Yin
2015-04-01
Although color medical images are important in clinical practice, they are usually converted to grayscale for further processing in pattern recognition, resulting in loss of rich color information. The sparse coding based linear spatial pyramid matching (ScSPM) and its variants are popular for grayscale image classification, but cannot extract color information. In this paper, we propose a joint sparse coding based SPM (JScSPM) method for the classification of color medical images. A joint dictionary can represent both the color information in each color channel and the correlation between channels. Consequently, the joint sparse codes calculated from a joint dictionary can carry color information, and therefore this method can easily transform a feature descriptor originally designed for grayscale images to a color descriptor. A color hepatocellular carcinoma histological image dataset was used to evaluate the performance of the proposed JScSPM algorithm. Experimental results show that JScSPM provides significant improvements as compared with the majority voting based ScSPM and the original ScSPM for color medical image classification. Copyright © 2014 Elsevier Ltd. All rights reserved.
Bornstein, Jacob
2017-05-01
The Galilee Medical Center (GMC) is unique in several aspects. Firstly, in the clinical aspect: In recent years, led by the Director of Medical Center, Dr. Masad Barhoum, a considerable momentum of development has taken place to reduce health discrepancies between the center and the periphery. Despite the under- financing of the health system in the Galilee, the GMC opened new clinical departments, introduced advanced medical technology and key staff members were added. This approach is depicted in publications presented in the current issue. Secondly, the aspect of medicine standoff: The GMC is the nearest hospital to the border with neighboring countries. It is also a tertiary center for trauma, due to the establishment of the Department of Neurosurgery, Department of Oral and Maxillofacial Surgery and the Departments of Orthopedic Surgery, general invasive radiology and invasive radiology of the brain. In recent years, the medical center treated hundreds of victims of the civil war in Syria, a third of them - women and children. The injured patients presented unique medical problems that are described in the papers in this issue. Thirdly, the research aspect: The medical center is the main teaching facility of medical students of the Faculty of Medicine in the Galilee of Bar-Ilan University. The Faculty of Medicine, led by the Dean, Prof. Ran Tur-Kaspa, promotes research and teaching in the medical center. Even before the establishment of the Faculty of Medicine, former hospital director, Prof. Shaul Shasha, not only extolled the importance of research, but established a research laboratory years ago. The laboratory continues to pursue translational research by the physicians of the medical center, led by Dr. Shifra Sela and Prof. Batya Kristal, and supported by the current medical center director, Dr. Masad Barhoum. Several studies conducted in this research laboratory are published herewith. With these unique aspects and despite the discrimination in funding for Galilee compared to the center of the country, the GMC has not remained stagnant. On the contrary, it established and promoted departments, technologies and research laboratories. This activity is expressed as aforesaid in the studies published in the current issue of "Harefuah" that you hold in your hands. The authors of the papers belong to the GMC and to the Faculty of Medicine of the University of Bar-Ilan University.
Development of the First Guideline for Professional Conduct in Medical Practice in Iran.
Saeedi Tehrani, Saeedeh; Nayeri, Fatemeh; Parsapoor, Alireza; Jafarian, Ali; Labaf, Ali; Mirzazadeh, Azim; Emadi Kouchak, Hamid; Shahi, Farhad; Ghasemzadeh, Nazafarin; Asghari, Fariba
2017-01-01
Professional behavior is first learned at the university. One of the necessary considerations in maintaining the professional environment of the university is establishing a set of codes for the behavior of physicians and medical students. This paper describes the process of developing the professional code of conduct in Tehran University of Medical Sciences, Tehran, Iran. A review of Iranian and international literature was performed to develop the first draft of the guideline. In sessions of group discussion by the authors, the articles of the draft were evaluated for relevancy, clarity, and lack of repetition. The draft was sent for evaluation to all participants, including the medical faculty members, residents, and medical students, four times and necessary corrections were made according to the comments received. The final guideline included 76 behavior codes in 6 categories, including altruism, honor and integrity, responsibility, respect, justice, and excellence. The codes of the guideline cover the physicians' commitments in the physician-patient, physician-colleague, and instructor-student relationships in order to improve the quality of the services. The Islamic and Iranian culture were taken into consideration in developing the guideline. Accordance with the administrative and educational conditions of the universities was ensured in developing the guideline and its acceptance was ensured through extensive surveys. Thus, it is expected that this guideline will be very effective in enhancing professional commitment in medical universities.
Dobson-Belaire, Wendy; Goodfield, Jason; Borrelli, Richard; Liu, Fei Fei; Khan, Zeba M
2018-01-01
Using diagnosis code-based algorithms is the primary method of identifying patient cohorts for retrospective studies; nevertheless, many databases lack reliable diagnosis code information. To develop precise algorithms based on medication claims/prescriber visits (MCs/PVs) to identify psoriasis (PsO) patients and psoriatic patients with arthritic conditions (PsO-AC), a proxy for psoriatic arthritis, in Canadian databases lacking diagnosis codes. Algorithms were developed using medications with narrow indication profiles in combination with prescriber specialty to define PsO and PsO-AC. For a 3-year study period from July 1, 2009, algorithms were validated using the PharMetrics Plus database, which contains both adjudicated medication claims and diagnosis codes. Positive predictive value (PPV), negative predictive value (NPV), sensitivity, and specificity of the developed algorithms were assessed using diagnosis code as the reference standard. Chosen algorithms were then applied to Canadian drug databases to profile the algorithm-identified PsO and PsO-AC cohorts. In the selected database, 183,328 patients were identified for validation. The highest PPVs for PsO (85%) and PsO-AC (65%) occurred when a predictive algorithm of two or more MCs/PVs was compared with the reference standard of one or more diagnosis codes. NPV and specificity were high (99%-100%), whereas sensitivity was low (≤30%). Reducing the number of MCs/PVs or increasing diagnosis claims decreased the algorithms' PPVs. We have developed an MC/PV-based algorithm to identify PsO patients with a high degree of accuracy, but accuracy for PsO-AC requires further investigation. Such methods allow researchers to conduct retrospective studies in databases in which diagnosis codes are absent. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Ortwein, Heiderose; Benz, Alexander; Carl, Petra; Huwendiek, Sören; Pander, Tanja; Kiessling, Claudia
2017-02-01
To investigate whether the Verona Coding Definitions of Emotional Sequences to code health providers' responses (VR-CoDES-P) can be used for assessment of medical students' responses to patients' cues and concerns provided in written case vignettes. Student responses in direct speech to patient cues and concerns were analysed in 21 different case scenarios using VR-CoDES-P. A total of 977 student responses were available for coding, and 857 responses were codable with the VR-CoDES-P. In 74.6% of responses, the students used either a "reducing space" statement only or a "providing space" statement immediately followed by a "reducing space" statement. Overall, the most frequent response was explicit information advice (ERIa) followed by content exploring (EPCEx) and content acknowledgement (EPCAc). VR-CoDES-P were applicable to written responses of medical students when they were phrased in direct speech. The application of VR-CoDES-P is reliable and feasible when using the differentiation of "providing" and "reducing space" responses. Communication strategies described by students in non-direct speech were difficult to code and produced many missings. VR-CoDES-P are useful for analysis of medical students' written responses when focusing on emotional issues. Students need precise instructions for their response in the given test format. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Wireless Headset Communication System
NASA Technical Reports Server (NTRS)
Lau, Wilfred K.; Swanson, Richard; Christensen, Kurt K.
1995-01-01
System combines features of pagers, walkie-talkies, and cordless telephones. Wireless headset communication system uses digital modulation on spread spectrum to avoid interference among units. Consists of base station, 4 radio/antenna modules, and as many as 16 remote units with headsets. Base station serves as network controller, audio-mixing network, and interface to such outside services as computers, telephone networks, and other base stations. Developed for use at Kennedy Space Center, system also useful in industrial maintenance, emergency operations, construction, and airport operations. Also, digital capabilities exploited; by adding bar-code readers for use in taking inventories.
Mirzabekov, Andrei; Guschin, Dmitry Y.; Chik, Valentine; Drobyshev, Aleksei; Fotin, Alexander; Yershov, Gennadiy; Lysov, Yuri
2002-01-01
This invention relates to using customized oligonucleotide microchips as biosensors for the detection and identification of nucleic acids specific for different genes, organisms and/or individuals in the environment, in food and in biological samples. The microchips are designed to convert multiple bits of genetic information into simpler patterns of signals that are interpreted as a unit. Because of an improved method of hybridizing oligonucleotides from samples to microchips, microchips are reusable and transportable. For field study, portable laser or bar code scanners are suitable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patra, Anirban; Wen, Wei; Martinez Saez, Enrique
This report describes the implementation of a crystal plasticity framework (VPSC) for irradiation hardening and plastic deformation in the finite element code, MOOSE. Constitutive models for irradiation hardening and the crystal plasticity framework are described in a previous report [1]. Here we describe these models briefly and then describe an algorithm for interfacing VPSC with finite elements. Example applications of tensile deformation of a dog bone specimen and a 3D pre-irradiated bar specimen performed using MOOSE are demonstrated.
Micro Computer Feedback Report for the Strategic Leader Development Inventory; Source Code
1994-03-01
SEL5 ;exit if error CALL SELZCT SCRZEN ;display select screen JC SEL4 ;no files in directory .------- display the files NOV BX, [BarPos] ;starting...SEL2 ;if not goto next test imp SEL4 ; Ecit SEL2: CUP AL,ODh ;in it a pick ? 3Z SEL3 ;if YES exit loop ------- see if an active control key was...file CALL READCOMFIG eread file into memory JC SEL5 ;exit to main menu CALL OPEN DATA FILE ;is data arailable? SEL4 : CALL RELEASE_ _MDR ;release mom