Sample records for barium fluoride array

  1. DANCE : a 4[pi] barium fluoride detector for measuring neutron capture on unstable nuclei /.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ullmann, J. L.; Haight, Robert C.; Hunt, L. F.

    2002-01-01

    Measurements of neutron capture on unstable nuclei are important for studies of s-process nucleosynthesis, nuclear waste transmutation, and stewardship science. A 160-element, 4{pi} barium fluoride detector array, and associated neutron flight path, is being constructed to make capture measurements at the moderated neutron spallation source at LANSCE. Measurements can be made on as little as 1 mg of sample material over energies from near thermal to near 100 keV. The design of the DANCE array is described and neutron flux measurements from flight path commissioning are shown. The array is expected to be complete by the end of 2002.

  2. Zirconium fluoride glass - Surface crystals formed by reaction with water

    NASA Technical Reports Server (NTRS)

    Doremus, R. H.; Bansal, N. P.; Bradner, T.; Murphy, D.

    1984-01-01

    The hydrated surfaces of a zirconium barium fluoride glass, which has potential for application in optical fibers and other optical elements, were observed by scanning electron microscopy. Crystalline zirconium fluoride was identified by analysis of X-ray diffraction patterns of the surface crystals and found to be the main constituent of the surface material. It was also found that hydrated zirconium fluorides form only in highly acidic fluoride solutions. It is possible that the zirconium fluoride crystals form directly on the glass surface as a result of its depletion of other ions. The solubility of zirconium fluoride is suggested to be probably much lower than that of barium fluoride (0.16 g/100 cu cm at 18 C). Dissolution was determined to be the predominant process in the initial stages of the reaction of the glass with water. Penetration of water into the glass has little effect.

  3. Effect of chloride incorporation on the crystallization of zirconium-barium-lanthanum-aluminum fluoride glass

    NASA Technical Reports Server (NTRS)

    Neilson, G. F.; Smith, G. L.; Weinberg, M. C.

    1985-01-01

    One aspect of the influence of preparation procedure on the crystallization behavior of a zirconium-barium-lanthanum-aluminum fluoride glass was studied. The crystallization pattern of this glass may be affected by the chlorine concentration within it. In particular, when such glasses are heated at low temperatures, the alpha-Ba-Zr-F6 crystalline phase forms only in those glasses which contain chloride.

  4. Carbide/fluoride/silver self-lubricating composite

    NASA Technical Reports Server (NTRS)

    Sliney, Harold E. (Inventor)

    1988-01-01

    A self-lubricating, friction and wear reducing composite material for use over a wide temperature spectrum from cryogenic temperature to about 900.degree. C. in a chemically reactive environment comprising silver, barium fluoride/calcium fluoride eutectic, and metal bonded chromium carbide.

  5. Electronic Devices with Barium Barrier Film and Process for Making Same

    DTIC Science & Technology

    1998-08-20

    structure of the barrier film on an atomic level 15 where the barrier .film is comprised of a plurality of contiguous monolayers, while FIG. 7B...yet another embodiment where the barrier film is comprised of a plurality of 20 contiguous monolayers in which different monolayers thereof are...barrier precursor compound effusion cell, for example a barium fluoride, strontium fluoride or the like effusion cell, is provided at 32, and has a

  6. Carbide-fluoride-silver self-lubricating composite

    NASA Technical Reports Server (NTRS)

    Sliney, Harold E. (Inventor)

    1987-01-01

    A self-lubricating, friction and wear reducing composite material is described for use over a wide temperature spectrum from cryogenic temperature to about 900 C in a chemically reactive environment comprising silver, barium fluoride/calcium fluoride eutectic, and metal bonded chromium carbide.

  7. Infrared/submillimeter optical properties data base

    NASA Technical Reports Server (NTRS)

    Alley, Phillip W.

    1989-01-01

    The general goal was to build a data base containing optical properties, such as reflectance, transmittance, refractive index, in the far infrared to submillimeter wavelength region. This data base would be limited to selected crystalline materials and temperature between 300 and 2 K. The selected materials were: lithium, lead, and strontium; the bromides of potassium and thallium; the carbides of silicone and tungsten; and the materials of KRS5, KRS6, diamond, and sapphire. Last summer, barium fluoride was selected as prototype material for building the data base. This summer the literature search, preparation of the data for barium fluoride was completed. In addition the literature search for data related to the compounds mentioned was completed. The current status is that barium fluoride is in a form suitable for a NASA internal publication. The papers containing the data on the other materials were xeroxed and they are ready to be reduced. On the reverse side, the top figure is a sample combination of data for the index of refraction at 300 K. The lower figure shows the transmittance vs wavelength at 300 and 80 K. These figures are a sample of many which were developed. Since barium fluoride was studied more than most of the materials listed above, it is clear that additional measurements should be made to fill in the gaps present on both temperature and wavelength data.

  8. Monolithic circuits for barium fluoride detectors used in nuclear physics experiments. CRADA final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varner, R.L.; Blankenship, J.L.; Beene, J.R.

    1998-02-01

    Custom monolithic electronic circuits have been developed recently for large detector applications in high energy physics where subsystems require tens of thousands of channels of signal processing and data acquisition. In the design and construction of these enormous detectors, it has been found that monolithic circuits offer significant advantages over discrete implementations through increased performance, flexible packaging, lower power and reduced cost per channel. Much of the integrated circuit design for the high energy physics community is directly applicable to intermediate energy heavy-ion and electron physics. This STTR project conducted in collaboration with researchers at the Holifield Radioactive Ion Beammore » Facility (HRIBF) at Oak Ridge National Laboratory, sought to develop a new integrated circuit chip set for barium fluoride (BaF{sub 2}) detector arrays based upon existing CMOS monolithic circuit designs created for the high energy physics experiments. The work under the STTR Phase 1 demonstrated through the design, simulation, and testing of several prototype chips the feasibility of using custom CMOS integrated circuits for processing signals from BaF{sub 2} detectors. Function blocks including charge-sensitive amplifiers, comparators, one shots, time-to-amplitude converters, analog memory circuits and buffer amplifiers were implemented during Phase 1 effort. Experimental results from bench testing and laboratory testing with sources were documented.« less

  9. Scintillator material

    DOEpatents

    Anderson, David F.; Kross, Brian J.

    1994-01-01

    An improved scintillator material comprising cerium fluoride is disclosed. Cerium fluoride has been found to provide a balance of good stopping power, high light yield and short decay constant that is superior to known scintillator materials such as thallium-doped sodium iodide, barium fluoride and bismuth germanate. As a result, cerium fluoride is favorably suited for use as a scintillator material in positron emission tomography.

  10. Scintillator material

    DOEpatents

    Anderson, David F.; Kross, Brian J.

    1992-01-01

    An improved scintillator material comprising cerium fluoride is disclosed. Cerium fluoride has been found to provide a balance of good stopping power, high light yield and short decay constant that is superior to known scintillator materials such as thallium-doped sodium iodide, barium fluoride and bismuth germanate. As a result, cerium fluoride is favorably suited for use as a scintillator material in positron emission tomography.

  11. Nanocomposite scintillator, detector, and method

    DOEpatents

    Cooke, D Wayne [Santa Fe, NM; McKigney, Edward A [Los Alamos, NM; Muenchausen, Ross E [Los Alamos, NM; Bennett, Bryan L [Los Alamos, NM

    2009-04-28

    A compact includes a mixture of a solid binder and at least one nanopowder phosphor chosen from yttrium oxide, yttrium tantalate, barium fluoride, cesium fluoride, bismuth germanate, zinc gallate, calcium magnesium pyrosilicate, calcium molybdate, calcium chlorovanadate, barium titanium pyrophosphate, a metal tungstate, a cerium doped nanophosphor, a bismuth doped nanophosphor, a lead doped nanophosphor, a thallium doped sodium iodide, a doped cesium iodide, a rare earth doped pyrosilicate, or a lanthanide halide. The compact can be used in a radiation detector for detecting ionizing radiation.

  12. Divalent fluoride doped cerium fluoride scintillator

    DOEpatents

    Anderson, David F.; Sparrow, Robert W.

    1991-01-01

    The use of divalent fluoride dopants in scintillator materials comprising cerium fluoride is disclosed. The preferred divalent fluoride dopants are calcium fluoride, strontium fluoride, and barium fluoride. The preferred amount of divalent fluoride dopant is less than about two percent by weight of the total scintillator. Cerium fluoride scintillator crystals grown with the addition of a divalent fluoride have exhibited better transmissions and higher light outputs than crystals grown without the addition of such dopants. These scintillators are useful in radiation detection and monitoring applications, and are particularly well suited for high-rate applications such as positron emission tomography (PET).

  13. Scintillator material

    DOEpatents

    Anderson, D.F.; Kross, B.J.

    1992-07-28

    An improved scintillator material comprising cerium fluoride is disclosed. Cerium fluoride has been found to provide a balance of good stopping power, high light yield and short decay constant that is superior to known scintillator materials such as thallium-doped sodium iodide, barium fluoride and bismuth germanate. As a result, cerium fluoride is favorably suited for use as a scintillator material in positron emission tomography. 4 figs.

  14. Scintillator material

    DOEpatents

    Anderson, D.F.; Kross, B.J.

    1994-06-07

    An improved scintillator material comprising cerium fluoride is disclosed. Cerium fluoride has been found to provide a balance of good stopping power, high light yield and short decay constant that is superior to known scintillator materials such as thallium-doped sodium iodide, barium fluoride and bismuth germanate. As a result, cerium fluoride is favorably suited for use as a scintillator material in positron emission tomography. 4 figs.

  15. Enhancing the detector for advanced neutron capture experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Couture, A.; Mosby, S.; Baramsai, B.

    2015-05-28

    The Detector for Advanced Neutron Capture Experiments (DANCE) has been used for extensive studies of neutron capture, gamma decay, photon strength functions, and prompt and delayed fission-gamma emission. Despite these successes, the potential measurements have been limited by the data acquisition hardware. We, thus, report on a major upgrade of the DANCE data acquisition that simultaneously enables strait-forward coupling to auxiliary detectors, including high-resolution high-purity germanium detectors and neutron tagging array. Furthermore, the upgrade will enhance the time domain accessible for time-of-flight neutron measurements as well as improve the resolution in the DANCE barium fluoride crystals for photons.

  16. Electrodeposition of molten silicon

    DOEpatents

    De Mattei, Robert C.; Elwell, Dennis; Feigelson, Robert S.

    1981-01-01

    Silicon dioxide is dissolved in a molten electrolytic bath, preferably comprising barium oxide and barium fluoride. A direct current is passed between an anode and a cathode in the bath to reduce the dissolved silicon dioxide to non-alloyed silicon in molten form, which is removed from the bath.

  17. Collecting Quality Infrared Spectra from Microscopic Samples of Suspicious Powders in a Sealed Cell.

    PubMed

    Kammrath, Brooke W; Leary, Pauline E; Reffner, John A

    2017-03-01

    The infrared (IR) microspectroscopical analysis of samples within a sealed-cell containing barium fluoride is a critical need when identifying toxic agents or suspicious powders of unidentified composition. The dispersive nature of barium fluoride is well understood and experimental conditions can be easily adjusted during reflection-absorption measurements to account for differences in focus between the visible and IR regions of the spectrum. In most instances, the ability to collect a viable spectrum is possible when using the sealed cell regardless of whether visible or IR focus is optimized. However, when IR focus is optimized, it is possible to collect useful data from even smaller samples. This is important when a minimal sample is available for analysis or the desire to minimize risk of sample exposure is important. While the use of barium fluoride introduces dispersion effects that are unavoidable, it is possible to adjust instrument settings when collecting IR spectra in the reflection-absorption mode to compensate for dispersion and minimize impact on the quality of the sample spectrum.

  18. METHOD OF PRODUCING URANIUM METAL BY ELECTROLYSIS

    DOEpatents

    Piper, R.D.

    1962-09-01

    A process is given for making uranium metal from oxidic material by electrolytic deposition on the cathode. The oxidic material admixed with two moles of carbon per one mole of uranium dioxide forms the anode, and the electrolyte is a mixture of from 40 to 75% of calcium fluoride or barium fluoride, 15 to 45% of uranium tetrafluoride, and from 10 to 20% of lithium fluoride or magnesium fluoride; the temperature of the electrolyte is between 1150 and 1175 deg C. (AEC)

  19. Cascaded Brillouin lasing in monolithic barium fluoride whispering gallery mode resonators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Guoping, E-mail: guoping.lin@femto-st.fr; Diallo, Souleymane; Saleh, Khaldoun

    2014-12-08

    We report the observation of stimulated Brillouin scattering and lasing at 1550 nm in barium fluoride (BaF{sub 2}) crystal. Brillouin lasing was achieved with ultra-high quality (Q) factor monolithic whispering gallery mode mm-size disk resonators. Overmoded resonators were specifically used to provide cavity resonances for both the pump and all Brillouin Stokes waves. Single and multiple Brillouin Stokes radiations with frequency shift ranging from 8.2 GHz up to 49 GHz have been generated through cascaded Brillouin lasing. BaF{sub 2} resonator-based Brillouin lasing can find potential applications for high-coherence lasers and microwave photonics.

  20. New insights into the mechanism of methoxyflurane nephrotoxicity and implications for anesthetic development (part 1): Identification of the nephrotoxic metabolic pathway.

    PubMed

    Kharasch, Evan D; Schroeder, Jesara L; Liggitt, H Denny; Park, Sang B; Whittington, Dale; Sheffels, Pamela

    2006-10-01

    Methoxyflurane nephrotoxicity results from biotransformation; inorganic fluoride is a toxic metabolite. Concern exists about potential renal toxicity from volatile anesthetic defluorination, but many anesthetics increase fluoride concentrations without consequence. Methoxyflurane is metabolized by both dechlorination to methoxydifluoroacetic acid (MDFA, which may degrade to fluoride) and O-demethylation to fluoride and dichloroacetatic acid. The metabolic pathway responsible for methoxyflurane nephrotoxicity has not, however, been identified, which was the aim of this investigation. Experiments evaluated methoxyflurane metabolite formation and effects of enzyme induction or inhibition on methoxyflurane metabolism and toxicity. Rats pretreated with phenobarbital, barium sulfate, or nothing were anesthetized with methoxyflurane, and renal function and urine methoxyflurane metabolite excretion were assessed. Phenobarbital effects on MDFA metabolism and toxicity in vivo were also assessed. Metabolism of methoxyflurane and MDFA in microsomes from livers of pretreated rats was determined in vitro. Phenobarbital pretreatment increased methoxyflurane nephrotoxicity in vivo (increased diuresis and blood urea nitrogen and decreased urine osmolality) and induced in vitro hepatic microsomal methoxyflurane metabolism to inorganic fluoride (2-fold), dichloroacetatic acid (1.5-fold), and MDFA (5-fold). In contrast, phenobarbital had no influence on MDFA renal effects in vivo or MDFA metabolism in vitro or in vivo. MDFA was neither metabolized to fluoride nor nephrotoxic. Barium sulfate diminished methoxyflurane metabolism and nephrotoxicity in vivo. Fluoride from methoxyflurane anesthesia derives from O-demethylation. Phenobarbital increases in methoxyflurane toxicity do not seem attributable to methoxyflurane dechlorination, MDFA toxicity, or MDFA metabolism to another toxic metabolite, suggesting that nephrotoxicity is attributable to methoxyflurane O-demethylation. Fluoride, one of many metabolites from O-demethylation, may be toxic and/or reflect formation of a different toxic metabolite. These results may have implications for interpreting anesthetic defluorination, volatile anesthetic use, and methods to evaluate anesthetic toxicity.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jia, Li-Ping; Zhang, Qiang; State Key Laboratory of Pollution Control and Resource Reuse

    Graphical abstract: Lanthanide ions doped bare earth rare earth fluoride nanocrystals are synthesized by hydrothermal technology and characterized. The down/up-conversion luminescence of them are discussed. - Highlights: • Mixed hydrothermal system H{sub 2}O–OA (EDA)–O-A(LO-A) is used for synthesis. • Barium rare earth fluoride nanocrystals are synthesized comprehensively. • Luminescence for down-conversion and up-conversion are obtained for these systems. - Abstract: Mixed hydrothermal system H{sub 2}O–OA (EDA)–O-A(LO-A) is developed to synthesize barium rare earth fluorides nanocrystals (OA = oleylamine, EDA = ethylenediamine, O-A = oleic acid and LO-A = linoleic acid). They are presented as BaREF{sub 5} (RE = Ce, Pr,more » Nd, Eu, Gd, Tb, Dy, Y, Tm, Lu) and Ba{sub 2}REF{sub 7} (RE = La, Sm, Ho, Er, Yb). The influence of reaction parameters (rare earth species, hydrothermal system and temperature) is checked on the phase and shape evolution of the fluoride nanocrystals. It is found that reaction time and temperature of these nanocrystals using EDA (180 °C, 6 h) is lower than those of them using OA (220 °C, 10 h). The photoluminescence properties of these fluorides activated by some rare earth ions (Nd{sup 3+}, Eu{sup 3+}, Tb{sup 3+}) are studied, and especially up-conversion luminescence of the four fluoride nanocrystal systems (Ba{sub 2}LaF{sub 7}:Yb, Tm(Er), Ba{sub 2}REF{sub 7}:Yb, Tm(Er) (RE = Gd, Y, Lu)) is observed.« less

  2. Infrared Optics Hot Pressed From Fluoride Glass

    NASA Astrophysics Data System (ADS)

    Turk, R. R.

    1982-02-01

    Optical figured surfaces were formed directly by hot pressing a fluoride glass in a closed die of tungsten carbide. Microduplication of the surface finish was also obtained. A glass composed of the fluorides of barium, thorium and zirconium or hafnium, and transmitting into the infrared out to 8 microns was press formed into an optical flat above its softening temperature and below its crystallization temperature. Also, small vitreous pieces were consolidated into larger pieces under moderate heat and pressure, thus avoiding the crystallization which occurs in large batches cooled from the melt.

  3. Synthesis and characterization of barium fluoride substituted zinc tellurite glasses

    NASA Astrophysics Data System (ADS)

    Aishwarya, K.; Vinitha, G.; Varma, G. Sreevidya; Asokan, S.; Manikandan, N.

    2017-12-01

    Glasses in the TeO2-ZnO-BaF2 system were prepared by standard melt quenching technique and were characterized for their thermal, optical and structural properties. Samples were found to show good thermal stability with values ranging above 100 °C for all the compositions. Optical bandgap and refractive index values were calculated from linear optical measurements using UV-Vis spectroscopy. Infrared spectra showed the presence of hydroxyl groups in the glasses indicating that the effect of fluorine was negligible in removing the hydroxyl impurities for the experimental conditions and compositions used. Raman measurements showed the modification occurring in the glass network due to addition of barium fluoride in terms of increase in the formation of non-bridging oxygen atoms compared to strong Te-O-Te linkages in the glass matrix.

  4. Electronic Devices with Barrier Film and Process for Making Same

    DTIC Science & Technology

    1998-08-20

    the barrier film on an atomic level where the barrier film is comprised of a plurality of contiguous monolayers, while FIG. 7B shows another...embodiment where the barrier film is comprised of a plurality of contiguous monolayers in which different monolayers thereof are formed of different...compound effusion cell, for example a barium fluoride, strontium fluoride or the like effusion cell, is provided at 32, and has a shutter 33. A

  5. Electronic Devices with Rubidium Barrier Film and Process for Making Same

    DTIC Science & Technology

    1998-08-20

    barrier film is comprised of a plurality of contiguous monolayers, while FIG. 7B shows another embodiment of the 20 invention where the barrier film is... plurality of contiguous monolayers in which different monolayers thereof are formed of different types of metal atoms. -10- FIG. 8 is a schematic...system directed toward the substrate 26. A diffusion barrier precursor compound effusion cell, for example a barium fluoride, strontium fluoride or the

  6. BMFO-PVDF electrospun fiber based tunable metamaterial structures for electromagnetic interference shielding in microwave frequency region

    NASA Astrophysics Data System (ADS)

    Revathi, Venkatachalam; Dinesh Kumar, Sakthivel; Subramanian, Venkatachalam; Chellamuthu, Muthamizhchelvan

    2015-11-01

    Metamaterial structures are artificial structures that are useful in controlling the flow of electromagnetic radiation. In this paper, composite fibers of sub-micron thickness of barium substituted magnesium ferrite (Ba0.2Mg0.8Fe2O4) - polyvinylidene fluoride obtained by electrospinning is used as a substrate to design electromagnetic interference shielding structures. While electrospinning improves the ferroelectric properties of the polyvinylidene fluoride, the presence of barium magnesium ferrite modifies the magnetic property of the composite fiber. The dielectric and magnetic properties at microwave frequency measured using microwave cavity perturbation technique are used to design the reflection as well as absorption based tunable metamaterial structures for electromagnetic interference shielding in microwave frequency region. For one of the structures, the simulation indicates that single negative metamaterial structure becomes a double negative metamaterial under the external magnetic field.

  7. Electronic Devices with Cesium Barrier Film and Process for Making Same

    DTIC Science & Technology

    1998-08-20

    interfacial structure of the barrier film on an atomic level where the barrier film is comprised of a plurality of contiguous monolayers, while FIG. 7B shows...another 20 embodiment where the barrier film is comprised of a plurality of contiguous monolayers in which different monolayers thereof are formed...compound effusion cell, for example a barium fluoride, strontium fluoride or the like effusion cell, is provided at 32, and has a shutter 33. A

  8. Process for Making a Semiconductor Device with Barrier Film Formation Using a Metal Halide and Products Thereof

    DTIC Science & Technology

    1998-08-20

    structure of the barrier film on an atomic level where the barrier film is comprised of a plurality of contiguous monolayers, while FIG. 7B shows...another embodiment where the barrier film is comprised of a plurality of i contiguous monolayers in which different monolayers thereof are formed... effusion cell, for example a barium fluoride, strontium fluoride or the like effusion cell, is provided at 32, and has a shutter 33. A 15 shutter 35

  9. Casting of Halide and Fluoride Alloys for Laser Windows

    DTIC Science & Technology

    1974-07-15

    mechanism leads to an inverse square root dependence of fracture strength on grain size. Since CaF2, SrFp and BaFp all exhibit at least microplastic ...flaws or microplasticity is the strength limiting factor is not known. 4.2.2 Solid-solution strengthening 4.2.2. 1 General If fracture in these...Temperature Microplasticity in SrF2 Single Crystals, " J. Appl. Phys. 41_(4) 1871 (1970). 12. T.S. Liu and C.H. Li, " Plasticity of Barium Fluoride

  10. Fluoride glass starting materials - Characterization and effects of thermal treatment

    NASA Technical Reports Server (NTRS)

    Chen, William; Dunn, Bruce; Shlichta, Paul; Neilson, George F.; Weinberg, Michael C.

    1987-01-01

    The production of heavy metal fluoride (HMF) glasses, and the effects of thermal treatments on the HMF glasses are investigated. ZrF4, BaF2, AlF3, LaF3, and NaF were utilized in the synthesis of zirconium-barium-lanthanum-aluminum-sodium fluoride glass. The purity of these starting materials, in particular ZrF4, is evaluated using XRD analysis. The data reveal that low temperature heating of ZrF4-H2O is effective in removing the water of hydration, but causes the production of ZrF4 and oxyfluorides; however, dehydration followed by sublimation results in the production of monoclinic ZrFe without water or oxyfluoride contaminants.

  11. Formation of anodic TiO2 nanotube arrays in NaOH added fluoride-ethylene glycol electrolyte for dye-sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Nyein, Nyein; Tan, Wai Kian; Kawamura, Go; Matsuda, Atsunori; Lockman, Zainovia

    2017-07-01

    TiO2 nanotube (TNT) arrays were formed by anodizing titanium foil in fluoride-ethylene glycol (EG) electrolyte added to it either water (H2O) or sodium hydroxide (NaOH) as oxidant. In NaOH added fluoride-EG electrolyte, 10 µm long TNT arrays were formed compared to 5 μm long nanotubes in H2O added fluoride-EG electrolyte. When NaOH was added to EG, the electrolyte pH was 9. As the pH of the electrolyte was rather high, surface etching of the nanotubes was reduced resulting in tubes with longer length. Moreover, the addition of NaOH into fluoride-EG resulted in the crystallization of anatase in the as-made TNT arrays. Annealing obviously improved the crystallinity of the oxide. The TNT arrays were then used as a photoanode in a dye-sensitized solar cell (DSSC). A photoconversion efficiency of 2.4 % was recorded with photocurrent of 6.9 mA/cm2.

  12. Highly aligned arrays of high aspect ratio barium titanate nanowires via hydrothermal synthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowland, Christopher C.; Zhou, Zhi; Malakooti, Mohammad H.

    2015-06-01

    We report on the development of a hydrothermal synthesis procedure that results in the growth of highly aligned arrays of high aspect ratio barium titanate nanowires. Using a multiple step, scalable hydrothermal reaction, a textured titanium dioxide film is deposited on titanium foil upon which highly aligned nanowires are grown via homoepitaxy and converted to barium titanate. Scanning electron microscope images clearly illustrate the effect the textured film has on the degree of orientation of the nanowires. The alignment of nanowires is quantified by calculating the Herman's Orientation Factor, which reveals a 58% improvement in orientation as compared to growthmore » in the absence of the textured film. The ferroelectric properties of barium titanate combined with the development of this scalable growth procedure provide a powerful route towards increasing the efficiency and performance of nanowire-based devices in future real-world applications such as sensing and power harvesting.« less

  13. 40 CFR Appendix I to Part 257 - Maximum Contaminant Levels (MCLs)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Drinking Water Act Chemical CAS No. MCL -(mg/l) Arsenic 7440-38-2 0.05 Barium 7440-39-3 1.0 Benzene 71-343... 107-06-2 0.005 1,1-Dichloroethylene 75-35-4 0.007 Endrin 75-20-8 0.0002 Fluoride 7 4.0 Lindane 58-89-9...

  14. 40 CFR Appendix I to Part 257 - Maximum Contaminant Levels (MCLs)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Drinking Water Act Chemical CAS No. MCL -(mg/l) Arsenic 7440-38-2 0.05 Barium 7440-39-3 1.0 Benzene 71-343... 107-06-2 0.005 1,1-Dichloroethylene 75-35-4 0.007 Endrin 75-20-8 0.0002 Fluoride 7 4.0 Lindane 58-89-9...

  15. 40 CFR Appendix I to Part 257 - Maximum Contaminant Levels (MCLs)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Drinking Water Act Chemical CAS No. MCL -(mg/l) Arsenic 7440-38-2 0.05 Barium 7440-39-3 1.0 Benzene 71-343... 107-06-2 0.005 1,1-Dichloroethylene 75-35-4 0.007 Endrin 75-20-8 0.0002 Fluoride 7 4.0 Lindane 58-89-9...

  16. 40 CFR Appendix I to Part 257 - Maximum Contaminant Levels (MCLs)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Drinking Water Act Chemical CAS No. MCL -(mg/l) Arsenic 7440-38-2 0.05 Barium 7440-39-3 1.0 Benzene 71-343... 107-06-2 0.005 1,1-Dichloroethylene 75-35-4 0.007 Endrin 75-20-8 0.0002 Fluoride 7 4.0 Lindane 58-89-9...

  17. A new perspective on metals and other contaminants in fluoridation chemicals*

    PubMed Central

    Mullenix, Phyllis J

    2014-01-01

    Background: Fluoride additives contain metal contaminants that must be diluted to meet drinking water regulations. However, each raw additive batch supplied to water facilities does not come labeled with concentrations per contaminant. This omission distorts exposure profiles and the risks associated with accidents and routine use. Objectives: This study provides an independent determination of the metal content of raw fluoride products. Methods: Metal concentrations were analyzed in three hydrofluorosilicic acid (HFS) and four sodium fluoride (NaF) samples using inductively coupled plasma-atomic emission spectrometry. Arsenic levels were confirmed using graphite furnace atomic absorption analysis. Results: Results show that metal content varies with batch, and all HFS samples contained arsenic (4.9–56.0 ppm) or arsenic in addition to lead (10.3 ppm). Two NaF samples contained barium (13.3–18.0 ppm) instead. All HFS (212–415 ppm) and NaF (3312–3630 ppm) additives contained a surprising amount of aluminum. Conclusions: Such contaminant content creates a regulatory blind spot that jeopardizes any safe use of fluoride additives. PMID:24999851

  18. Microgravity

    NASA Image and Video Library

    1998-02-05

    Sections of ZBLAN fibers pulled in a conventional 1-g process (left) and in experiments aboard NASA's KC-135 low-gravity aircraft. The rough surface of the 1-g fiber indicates surface defects that would scatter an optical signal and greatly degrade its quality. ZBLAN is part of the family of heavy-metal fluoride glasses (fluorine combined zirconium, barium, lanthanum, aluminum, and sodium). NASA is conducting research on pulling ZBLAN fibers in the low-g environment of space to prevent crystallization that limits ZBLAN's usefulness in optical fiber-based communications. ZBLAN is a heavy-metal fluoride glass that shows exceptional promise for high-throughput communications with infrared lasers. Photo credit: NASA/Marshall Space Flight Center

  19. Water Atomization of Barium Fluoride: Calcium Fluoride for Enhanced Flow Characteristics of PS304 Feedstock Powder Blend

    NASA Technical Reports Server (NTRS)

    Stanford, Malcolm K.; DellaCorte, Christopher

    2003-01-01

    PS304 is a plasma spray deposited solid lubricant coating with feedstock composed of NiCr, Cr2O3, Ag, and BaF2-CaF2 powders. The effects of rounded BaF2-CaF2 particles on the gravity-fed flow characteristics of PS304 feedstock have been investigated. The BaF2-CaF2 powder was fabricated by water atomization using four sets of process parameters. Each of these powders was then characterized by microscopy and classified by screening to obtain 45 to 106 micron particles and added incrementally from 0 to 10 wt% to the other constituents of the PS304 feedstock, namely nichrome, chromia, and silver powders. The relationship between feedstock flow rate, measured with the Hall flowmeter, and concentration of fluorides was found to be linear in each case. The slopes of the lines were between those of the linear relationships previously reported using angular and spherical fluorides and were closer to the relationship predicted using the rule of mixtures. The results offer a fluoride fabrication technique potentially more cost-effective than gas atomization processes or traditional comminution processes.

  20. 40 CFR Appendix III to Part 265 - EPA Interim Primary Drinking Water Standards

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 27 2012-07-01 2012-07-01 false EPA Interim Primary Drinking Water... Water Standards Parameter Maximum level (mg/l) Arsenic 0.05 Barium 1.0 Cadmium 0.01 Chromium 0.05 Fluoride 1.4-2.4 Lead 0.05 Mercury 0.002 Nitrate (as N) 10 Selenium 0.01 Silver 0.05 Endrin 0.0002 Lindane...

  1. 40 CFR Appendix III to Part 265 - EPA Interim Primary Drinking Water Standards

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 27 2013-07-01 2013-07-01 false EPA Interim Primary Drinking Water... Water Standards Parameter Maximum level (mg/l) Arsenic 0.05 Barium 1.0 Cadmium 0.01 Chromium 0.05 Fluoride 1.4-2.4 Lead 0.05 Mercury 0.002 Nitrate (as N) 10 Selenium 0.01 Silver 0.05 Endrin 0.0002 Lindane...

  2. PRODUCTION OF ACTINIDE METAL

    DOEpatents

    Knighton, J.B.

    1963-11-01

    A process of reducing actinide oxide to the metal with magnesium-zinc alloy in a flux of 5 mole% of magnesium fluoride and 95 mole% of magnesium chloride plus lithium, sodium, potassium, calcium, strontium, or barium chloride is presented. The flux contains at least 14 mole% of magnesium cation at 600-- 900 deg C in air. The formed magnesium-zinc-actinide alloy is separated from the magnesium-oxide-containing flux. (AEC)

  3. Diode-pumped Tunable 3 Micron Laser Sources

    DTIC Science & Technology

    2000-02-21

    DoD Ballistic Missile Defense Organization U.S. Army Space and Missile Defense Command SBIR Phase I Final Report AC Materials, Inc. 2721 Forsyth...pumped tunable 3 micron laser sources 6. AUTHORISI Arlete Cassanho, Hans Jenssen 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) AC Materials, Inc...impurities in the final crystal, starting materials for the crystal growth were prepared at AC Materials from optical grade barium fluoride and

  4. Microgravity

    NASA Image and Video Library

    1998-02-05

    This graph depicts the increased signal quality possible with optical fibers made from ZBLAN, a family of heavy-metal fluoride glasses (fluorine combined zirconium, barium, lanthanum, aluminum, and sodium) as compared to silica fibers. NASA is conducting research on pulling ZBLAN fibers in the low-g environment of space to prevent crystallization that limits ZBLAN's usefulness in optical fiber-based communications. In the graph, a line closer to the black theoretical maximum line is better. Photo credit: NASA/Marshall Space Flight Center

  5. Selections From Kung-Jen JIH-PAO (Source Span: 9 May-30 June 1961) Number 7 -Communist China.

    DTIC Science & Technology

    1961-08-17

    sulphate Ammonium hydrogen carbonate Sodium borate Titaniüm-iron powder Sodium fluoride Silicon dioxide Barium chloride beryllium carbonate ...Vinzenstrasse, 22a :■ P. 0. Box 3521 Aachen, Germany Washington 7> B.C. , Institute de Sociologie Solvay Rue du Chatelain, k9 Brussels, Belgium State... Sodium nitrite Specifications Pure n industrial Boric Acid " A^ua ammonia " Magnesium sulphate Industrial Manganese tedroxide Pure

  6. Robotic Tactile Sensors Fabricated from a Monolithic Silicon Integrated Circuit and a Piezoelectric Polyvinylidene Fluoride Thin Film

    DTIC Science & Technology

    1991-12-01

    gradient will be presented. -Finally, a brief discussion of various piezoelectric materials will be presented, including Rochelle salt, quartz, barium...consideringr a microscopic-level dipole arrangement. The strain induced by ain external force or a tempem at ure gradient changes hie orientation of the...pyroelectric materials, an externally applied temperature gradient can be related to the resulting polarization by a l)yroelectric * constant.1 p (130

  7. The effect of processing and compositional changes on the tribology of PM212 in air

    NASA Technical Reports Server (NTRS)

    Bogdanski, Michael S.; Sliney, Harold E.; Dellacorte, Christopher

    1993-01-01

    The effects of processing and compositional variations on the tribological performance of PM212 were studied. PM212 is a self lubricating powder metallurgy composite, comprised of a wear resistant metal bonded chromium carbide matrix, containing the solid lubricants barium fluoride/calcium fluoride eutectic and silver. Several composites were formulated which had lubricant, matrix, and processing variations. Processing variations included sintering and hot isostatic pressing. Pins fabricated from the composites were slid against superalloys disks in a pin-on-disk tribometer to study the tribological properties. Several composites exhibited low friction and wear in sliding against a nickel based superalloy. The tribological performance by several different composites showed that the composition of PM212 can be altered without dramatically affecting performance.

  8. Image Information Obtained Using a Charge-Coupled Device (CCD) Camera During an Immersion Liquid Evaporation Process for Measuring the Refractive Index of Solid Particles.

    PubMed

    Niskanen, Ilpo; Sutinen, Veijo; Thungström, Göran; Räty, Jukka

    2018-06-01

    The refractive index is a fundamental physical property of a medium, which can be used for the identification and purity issues of all media. Here we describe a refractive index measurement technique to determine simultaneously the refractive index of different solid particles by monitoring the transmittance of light from a suspension using a charge-coupled device (CCD) camera. An important feature of the measurement is the liquid evaporation process for the refractive index matching of the solid particle and the immersion liquid; this was realized by using a pair of volatile and non-volatile immersion liquids. In this study, refractive indices of calcium fluoride (CaF 2 ) and barium fluoride (BaF 2 ) were determined using the proposed method.

  9. Sierra Army Depot, Phase 1, Remedial Investigation/Feasibility Study, Lassen County, California. Final Remedial Investigation

    DTIC Science & Technology

    1991-10-01

    8.3.1.2 Cadmium ............................ 8-8 8.3.1.3 Lead .... ............................ 8-8 8.3.1.4 Zinc .... ............................ 8-8...Beryllium, Cadmium , Chromium, Cobalt, Copper, Fluoride Salts, Lead, Mercury, Molydenum, Nickel, Selenium, Silver, Thallium, Vanadium, Zinc . I ~ 2 ,4... cadmium (4.070 ;&g/L), copper (20.100 ug/L), and zinc (28.700 ug/L). Round 2 background 3 groundwater results include arsenic (7.700 g/L), barium

  10. Quality of ground water in the Columbia Basin, Washington, 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turney, G.L.

    1986-01-01

    Groundwater from 188 sites in the Columbia Basin of central Washington was sampled and analyzed in 1983 for pH, specific conductance, and concentrations of fecal coliform bacteria, major dissolved ions, and dissolved iron, manganese, and nitrate. Twenty of the samples were also analyzed for concentrations of dissolved trace metals including aluminum, arsenic, barium, cadmium, chromium, copper, lead, mercury, selenium, silver, and zinc. The predominant water types were sodium bicarbonate and calcium bicarbonate. The sodium bicarbonate water samples had higher pH, fluoride, and sodium:adsorption ratio values than samples with other water types. Most trace metal concentrations were also < 10 ug/Lmore » except for barium and zinc, which had maximum concentrations of 170 and 600 ug/L, respectively. Nitrate concentrations were < 1.0 mg/L in water from more than half the wells sampled. US EPA (Environmental Protection Agency) drinking water regulations were exceeded in several samples, most commonly involving pH and concentrations of fluoride, nitrate, and dissolved solids in samples from Adams and Grant Counties. Generally, the historical data lead to similar conclusions about the quality of groundwater in the Columbia Basin region. However, historical samples had higher dissolved solids concentrations in Douglas County. Historical samples also included fewer sodium bicarbonate type waters in the region as a whole than the 1983 samples. 24 refs., 2 figs., 4 tabs.« less

  11. Ytterbium trifluoride as a radiopaque agent for dental cements.

    PubMed

    Collares, F M; Ogliari, F A; Lima, G S; Fontanella, V R C; Piva, E; Samuel, S M W

    2010-09-01

    To evaluate the radiopacity, degree of conversion (DC) and flexural strength of an experimental dental cement, with several added radiopaque substances. Titanium dioxide, quartz, zirconia, bismuth oxide, barium sulphate and ytterbium trifluoride were added to the experimental cement in five different concentrations. Radiopacity was evaluated with a phosphor plate system, and the radiodensity of specimens was compared with an aluminium step-wedge. DC was evaluated with FT-infrared spectroscopy following 20 s of photo-activation. Specimens with dimensions of 12 x 2 x 2 mm were used for the flexural strength test. Data were analysed with two-way anova and Tukey's post hoc test. Radiopacity of the experimental dental cements with barium sulphate and bismuth oxide at 40% and ytterbium fluoride at 30% and 40% showed no significant differences in comparison with 3 mm of Al (181, 96). The experimental dental cements with at least 30% added ytterbium trifluoride had satisfactory radiopacity without influencing other properties.

  12. Master Environmental Plan, Jefferson Proving Ground, Madison, Indiana

    DTIC Science & Technology

    1990-11-15

    Act Comprehensive Environmental Response, Compensation, and Liability Act cadmium Code of Federal Regulations carbon monoxide carbon dioxide...T) Arsenic (III)@ 360 190 0.175 (C) 0.022 (C) Barium 1,000 (D) Beryl 1i urn 1.17 (C) 0.068 (C) Cadmium #@ (1.128[ln Hard*]-3.828) p(0.7852[ln...all waters. Fluoride shall not exceed 2.0 mg/1 in all waters, except the Ohio River and Interstate Wabash River where it shall not exceed 1.0 mg/1

  13. Experimental evaluation of chromium-carbide-based solid lubricant coatings for use to 760 C

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher

    1987-01-01

    A research program is described which further developed and investigated chromium carbide based self-lubricating coatings for use to 760 C. A bonded chromium carbide was used as the base stock because of the known excellent wear resistance and the chemical stability of chromium carbide. Additives were silver and barium fluoride/calcium fluoride eutectic. The three coating components were blended in powder form, applied to stainless steel substrates by plasma spraying and then diamond ground to the desired coating thickness. A variety of coating compositions was tested to determine the coating composition which gave optimum tribological results. Coatings were tested in air, helium, and hydrogen at temperatures from 25 to 760 C. Several counterface materials were evaluated with the objective of discovering a satisfactory metal/coating sliding combination for potential applications, such as piston ring/cylinder liner couples for Stirling engines. In general, silver and fluoride additions to chromium carbide reduced the friction coefficient and increased the wear resistance relative to the unmodified coating. The lubricant additives acted synergistically in reducing friction and wear.

  14. Synthesis and characterization of barium silicide (BaSi2) nanowire arrays for potential solar applications.

    PubMed

    Pokhrel, Ankit; Samad, Leith; Meng, Fei; Jin, Song

    2015-11-07

    In order to utilize nanostructured materials for potential solar and other energy-harvesting applications, scalable synthetic techniques for these materials must be developed. Herein we use a vapor phase conversion approach to synthesize nanowire (NW) arrays of semiconducting barium silicide (BaSi2) in high yield for the first time for potential solar applications. Dense arrays of silicon NWs obtained by metal-assisted chemical etching were converted to single-crystalline BaSi2 NW arrays by reacting with Ba vapor at about 930 °C. Structural characterization by X-ray diffraction and high-resolution transmission electron microscopy confirm that the converted NWs are single-crystalline BaSi2. The optimal conversion reaction conditions allow the phase-pure synthesis of BaSi2 NWs that maintain the original NW morphology, and tuning the reaction parameters led to a controllable synthesis of BaSi2 films on silicon substrates. The optical bandgap and electrochemical measurements of these BaSi2 NWs reveal a bandgap and carrier concentrations comparable to previously reported values for BaSi2 thin films.

  15. Enhanced dielectric properties of poly(vinylidene fluoride) composites filled with nano iron oxide-deposited barium titanate hybrid particles

    NASA Astrophysics Data System (ADS)

    Zhang, Changhai; Chi, Qingguo; Dong, Jiufeng; Cui, Yang; Wang, Xuan; Liu, Lizhu; Lei, Qingquan

    2016-09-01

    We report enhancement of the dielectric permittivity of poly(vinylidene fluoride) (PVDF) generated by depositing magnetic iron oxide (Fe3O4) nanoparticles on the surface of barium titanate (BT) to fabricate BT-Fe3O4/PVDF composites. This process introduced an external magnetic field and the influences of external magnetic field on dielectric properties of composites were investigated systematically. The composites subjected to magnetic field treatment for 30 min at 60 °C exhibited the largest dielectric permittivity (385 at 100 Hz) when the BT-Fe3O4 concentration is approximately 33 vol.%. The BT-Fe3O4 suppressed the formation of a conducting path in the composite and induced low dielectric loss (0.3) and low conductivity (4.12 × 10-9 S/cm) in the composite. Series-parallel model suggested that the enhanced dielectric permittivity of BT-Fe3O4/PVDF composites should arise from the ultrahigh permittivity of BT-Fe3O4 hybrid particles. However, the experimental results of the BT-Fe3O4/PVDF composites treated by magnetic field agree with percolation theory, which indicates that the enhanced dielectric properties of the BT-Fe3O4/PVDF composites originate from the interfacial polarization induced by the external magnetic field. This work provides a simple and effective way for preparing nanocomposites with enhanced dielectric properties for use in the electronics industry.

  16. Enhanced dielectric properties of poly(vinylidene fluoride) composites filled with nano iron oxide-deposited barium titanate hybrid particles.

    PubMed

    Zhang, Changhai; Chi, Qingguo; Dong, Jiufeng; Cui, Yang; Wang, Xuan; Liu, Lizhu; Lei, Qingquan

    2016-09-16

    We report enhancement of the dielectric permittivity of poly(vinylidene fluoride) (PVDF) generated by depositing magnetic iron oxide (Fe3O4) nanoparticles on the surface of barium titanate (BT) to fabricate BT-Fe3O4/PVDF composites. This process introduced an external magnetic field and the influences of external magnetic field on dielectric properties of composites were investigated systematically. The composites subjected to magnetic field treatment for 30 min at 60 °C exhibited the largest dielectric permittivity (385 at 100 Hz) when the BT-Fe3O4 concentration is approximately 33 vol.%. The BT-Fe3O4 suppressed the formation of a conducting path in the composite and induced low dielectric loss (0.3) and low conductivity (4.12 × 10(-9) S/cm) in the composite. Series-parallel model suggested that the enhanced dielectric permittivity of BT-Fe3O4/PVDF composites should arise from the ultrahigh permittivity of BT-Fe3O4 hybrid particles. However, the experimental results of the BT-Fe3O4/PVDF composites treated by magnetic field agree with percolation theory, which indicates that the enhanced dielectric properties of the BT-Fe3O4/PVDF composites originate from the interfacial polarization induced by the external magnetic field. This work provides a simple and effective way for preparing nanocomposites with enhanced dielectric properties for use in the electronics industry.

  17. Enhanced dielectric properties of poly(vinylidene fluoride) composites filled with nano iron oxide-deposited barium titanate hybrid particles

    PubMed Central

    Zhang, Changhai; Chi, Qingguo; Dong, Jiufeng; Cui, Yang; Wang, Xuan; Liu, Lizhu; Lei, Qingquan

    2016-01-01

    We report enhancement of the dielectric permittivity of poly(vinylidene fluoride) (PVDF) generated by depositing magnetic iron oxide (Fe3O4) nanoparticles on the surface of barium titanate (BT) to fabricate BT–Fe3O4/PVDF composites. This process introduced an external magnetic field and the influences of external magnetic field on dielectric properties of composites were investigated systematically. The composites subjected to magnetic field treatment for 30 min at 60 °C exhibited the largest dielectric permittivity (385 at 100 Hz) when the BT–Fe3O4 concentration is approximately 33 vol.%. The BT–Fe3O4 suppressed the formation of a conducting path in the composite and induced low dielectric loss (0.3) and low conductivity (4.12 × 10−9 S/cm) in the composite. Series-parallel model suggested that the enhanced dielectric permittivity of BT–Fe3O4/PVDF composites should arise from the ultrahigh permittivity of BT–Fe3O4 hybrid particles. However, the experimental results of the BT–Fe3O4/PVDF composites treated by magnetic field agree with percolation theory, which indicates that the enhanced dielectric properties of the BT–Fe3O4/PVDF composites originate from the interfacial polarization induced by the external magnetic field. This work provides a simple and effective way for preparing nanocomposites with enhanced dielectric properties for use in the electronics industry. PMID:27633958

  18. The Effect of Compositional Tailoring on the Thermal Expansion and Tribological Properties of PS300: A Solid Lubricant Composite Coating

    NASA Technical Reports Server (NTRS)

    DellaCorte, C.; Fellenstein, J. A.

    1996-01-01

    This paper describes a research program in which the goal is to alter the thermal expansion coefficient of a composite solid lubricant coating, PS300, by compositional tailoring. PS300 is a plasma sprayed coating consisting of chrome oxide, silver and barium fluoride/calcium fluoride eutectic in NiCr binder. By adjusting the composition, the thermal expansion coefficient can be altered, and hence chosen, to more closely match a selected substrate preventing coating spallation at extreme temperatures. Thermal expansion coefficients (CTE) for a variety of compositions were measured from 25 to 800 C using a commercial dilatometer. The CTE's ranged from 7.0 to 13 x lO(exp -6)/deg C depending on the binder content. Subsequent tribological testing of a modified composition indicated that friction and wear properties were relatively insensitive to compositional tailoring.

  19. Complex refractive index measurements for BaF 2 and CaF 2 via single-angle infrared reflectance spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly-Gorham, Molly Rose K.; DeVetter, Brent M.; Brauer, Carolyn S.

    We have re-investigated the optical constants n and k for the homologous series of inorganic salts barium fluoride (BaF2) and calcium fluoride (CaF2) using a single-angle near-normal incidence reflectance device in combination with a calibrated Fourier transform infrared (FTIR) spectrometer. Our results are in good qualitative agreement with most previous works. However, certain features of the previously published data near the reststrahlen band exhibit distinct differences in spectral characteristics. Notably, our measurements of BaF2 do not include a spectral feature in the ~250 cm-1 reststrahlen band that was previously published. Additionally, CaF2 exhibits a distinct wavelength shift relative to themore » model derived from previously published data. We confirmed our results with recently published works that use significantly more modern instrumentation and data reduction techniques« less

  20. Clock distribution for BaF2 readout electronics at CSNS-WNS

    NASA Astrophysics Data System (ADS)

    He, Bing; Cao, Ping; Zhang, De-Liang; Wang, Qi; Zhang, Ya-Xi; Qi, Xin-Cheng; An, Qi

    2017-01-01

    A BaF2 (Barium Fluoride) detector array is designed to precisely measure the (n, γ) cross section at the CSNS-WNS (white neutron source at China Spallation Neutron Source). It is a 4π solid angle-shaped detector array consisting of 92 BaF2 crystal elements. To discriminate signals from the BaF2 detector, a pulse shape discrimination method is used, supported by a waveform digitization technique. There are 92 channels for digitizing. The precision and synchronization of clock distribution restricts the performance of waveform digitizing. In this paper, a clock prototype for the BaF2 readout electronics at CSNS-WNS is introduced. It is based on the PXIe platform and has a twin-stage tree topology. In the first stage, clock is synchronously distributed from the tree root to each PXIe crate through a coaxial cable over a long distance, while in the second stage, the clock is further distributed to each electronic module through a PXIe dedicated differential star bus. With the help of this topology, each tree node can fan out up to 20 clocks with 3U size. Test results show the clock jitter is less than 20 ps, which meets the requirements of the BaF2 readout electronics. Besides, this clock system has the advantages of high density, simplicity, scalability and cost saving, so it can be useful for other clock distribution applications. Supported by National Research and Development plan (2016 YFA0401602) NSAF (U1530111) and National Natural Science Foundation of China (11005107)

  1. Electrolytic process for preparing uranium metal

    DOEpatents

    Haas, Paul A.

    1990-01-01

    An electrolytic process for making uranium from uranium oxide using Cl.sub.2 anode product from an electrolytic cell to react with UO.sub.2 to form uranium chlorides. The chlorides are used in low concentrations in a melt comprising fluorides and chlorides of potassium, sodium and barium in the electrolytic cell. The electrolysis produces Cl.sub.2 at the anode that reacts with UO.sub.2 in the feed reactor to form soluble UCl.sub.4, available for a continuous process in the electrolytic cell, rather than having insoluble UO.sub.2 fouling the cell.

  2. Amelogenin-assisted ex vivo remineralization of human enamel: effects of supersaturation degree and fluoride concentration

    PubMed Central

    Fan, Yuwei; Nelson, James R.; Alvarez, Jason R.; Hagan, Joseph; Berrier, Allison; Xu, Xiaoming

    2011-01-01

    The formation of organized nanocrystals that resemble enamel is crucial for successful enamel remineralization. Calcium, phosphate and fluoride ions and amelogenin are important ingredients for the formation of organized hydroxyapatite (HAP) crystals in vitro. However, the effects of these remineralization agents on the enamel crystal morphology have not been thoroughly studied. The objective of this study was to investigate the effects of fluoride ions, supersaturation degree and amelogenin on the crystal morphology and organization of ex vivo remineralized human enamel. Extracted third molars were sliced thin and acid-etched to provide the enamel surface for immersion in different remineralization solutions. The crystal morphology and mineral phase of the remineralized enamel surface were analyzed by FE-SEM, ATR-FTIR and XRD. The concentration of fluoride and supersaturation degree of hydroxyapatite had significant effects on the crystal morphology and crystal organization, which varied from plate-like loose crystals to rod-like densely packed nanocrystal arrays. Densely packed arrays of fluoridated hydroxyapatite nanorods were observed under the following conditions: σ(HAP) = 10.2±2.0 with fluoride 1.5±0.5 mg/L and amelogenin 40±10 µg/mL, pH 6.8±0.4. A phase diagram summarized the conditions that form dense or loose hydroxyapatite nanocrystal structures. This study provides the basis for the development of novel dental materials for caries management. PMID:21256987

  3. In vitro modifications of the scala tympani environment and the cochlear implant array surface.

    PubMed

    Kontorinis, Georgios; Scheper, Verena; Wissel, Kirsten; Stöver, Timo; Lenarz, Thomas; Paasche, Gerrit

    2012-09-01

    To investigate the influence of alterations of the scala tympani environment and modifications of the surface of cochlear implant electrode arrays on insertion forces in vitro. Research experimental study. Fibroblasts producing neurotrophic factors were cultivated on the surface of Nucleus 24 Contour Advance electrodes. Forces were recorded by an Instron 5542 Force Measurement System as three modified arrays were inserted into an artificial scala tympani model filled with phosphate-buffered saline (PBS). The recorded forces were compared to control groups including three unmodified electrodes inserted into a model filled with PBS (unmodified environment) or Healon (current practice). Fluorescence microscopy was used before and after the insertions to identify any remaining fibroblasts. Additionally, three Contour Advance electrodes were inserted into an artificial model, filled with alginate/barium chloride solution at different concentrations, while insertion forces were recorded. Modification of the scala tympani environment with 50% to 75% alginate gel resulted in a significant decrease in the insertion forces. The fibroblast-coated arrays also led to decreased forces comparable to those recorded with Healon. Fluorescence microscopy revealed fully cell-covered arrays before and partially covered arrays after the insertion; the fibroblasts on the arrays' modiolar surface remained intact. Modifications of the scala tympani's environment with 50% to 75% alginate/barium chloride and of the cochlear implant electrode surface with neurotrophic factor-producing fibroblasts drastically reduce the insertion forces. As both modifications may serve future intracochlear therapies, it is expected that these might additionally reduce possible insertion trauma. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  4. Solid state neutron detector and method for use

    DOEpatents

    Doty, F. Patrick; Zwieback, Ilya; Ruderman, Warren

    2002-01-01

    Crystals of lithium tetraborate or alpha-barium borate had been found to be neutron detecting materials. The crystals are prepared using known crystal growing techniques, wherein the process does not include the common practice of using a fluxing agent, such as sodium oxide or sodium fluoride, to reduce the melting temperature of the crystalline compound. Crystals prepared by this method can be sliced into thin single or polycrystalline wafers, or ground to a powder and prepared as a sintered compact or a print paste, and then configured with appropriate electronic hardware, in order to function as neutron detectors.

  5. Structural, morphological and Raman studies on hybridized PVDF/BaTiO3 nanocomposites

    NASA Astrophysics Data System (ADS)

    Rajamanickam, N.; Jayakumar, K.; Ramachandran, K.

    2017-05-01

    Hybridized nanocomposites of polyvinylidene fluoride (PVDF) and nano - barium titanate (BaTiO3) were prepared using the solution casting method for different concentrations of nano-BaTiO3 and were characterized by X-ray diffraction and scanning electron microscopy. The flower like structure for morphology was observed in SEM. Raman analysis showed that the modified BaTiO3 particles, due to higher specific surfaces, induce, predominantly, the crystallization of the electrically active β-phase of PVDF, while the initial micron size particles induce the formation of the most common but non-polar α-crystal form.

  6. Molecular structures of (3-aminopropyl)trialkoxysilane on hydroxylated barium titanate nanoparticle surfaces induced by different solvents and their effect on electrical properties of barium titanate based polymer nanocomposites

    NASA Astrophysics Data System (ADS)

    Fan, Yanyan; Wang, Guanyao; Huang, Xingyi; Bu, Jing; Sun, Xiaojin; Jiang, Pingkai

    2016-02-01

    Surface modification of nanoparticles by grafting silane coupling agents has proven to be a significant approach to improve the interfacial compatibility between inorganic filler and polymer matrix. However, the impact of grafted silane molecular structure after the nanoparticle surface modification, induced by the utilized solvents and the silane alkoxy groups, on the electrical properties of the corresponding nanocomposites, has been seldom investigated. Herein, the silanization on the surface of hydroxylated barium titanate (BT-OH) nanoparticles was introduced by using two kinds of trialkoxysilane, 3-aminopropyltriethoxysilane (AMEO) and 3-aminopropyltrimethoxysilane (AMMO), with different solvents (toluene and ethanol), respectively. Solid-state 13C, 29Si nuclear magnetic resonance (NMR) spectroscopy and high-resolution X-ray photoelectron spectroscopy (XPS) were employed to validate the structure differences of alkoxysilane attachment to the nanoparticles. The effect of alkoxysilane structure attached to the nanoparticle surface on the dielectric properties of the BT based poly(vinylidene fluoride) (PVDF) nanocomposites were investigated. The results reveal that the solvents used for BT nanoparticle surface modification exhibit a significant effect on the breakdown strength of the nanocomposites. Nevertheless, the alkoxy groups of silane show a marginal influence on the dielectric properties of the nanocomposites. These research results provide important insights into the fabrication of advanced polymer nanocomposites for dielectric applications.

  7. [Determination of fumes and their elements from flux cored arc welding].

    PubMed

    Matczak, Wanda; Przybylska-Stanisławska, Magdalena

    2004-01-01

    The aim of this work was to assay the concentration levels and composition of welding fumes, released during flux cored arc welding, to assess exposure of welders. Concentrations and welding fume components, such as iron, manganese, chromium (including the soluble and chromium VI), nickel, copper, calcium, aluminium, barium, and fluorides (including hydrogen fluoride) were determined in the air of six industrial plants (shipyards, mechanical engineering plants and a power station) at the breathing zones of the welders who used 10 types of wires during flux cored arc welding. The following determination methods were used: gravimetry (fumes), AAS (metals), and spectrophotometry (chromium VI, fluorides--including hydrogen fluoride). The results made it possible to determine the relationship between concentrations of welding fume and its elements, and to assess worker's exposure. Time weighted average concentrations of the welding fumes and its elements at the worker's breathing zone were: mg/m3: dust 0.2-24.3; Fe 0.2-6.7; Mn 0.01-1.8; Cr 0.004-0.5 (mainly Cr III); Ca 0.004-2.5; Ni < or = 0.004; Cu < 0.002-0.05; Al < 0.14-0.4; Ba < 0.14; F- 0.07-0.43. The welders using some types of flux cored welding wires worked in conditions harmful to their health owing to the considerably exceeded TLV value for fume and MAC values for manganese, and occasional slightly excessive MAC values for calcium and iron.

  8. Performance and Durability of High Temperature Foil Air Bearings for Oil-Free Turbomachinery

    NASA Technical Reports Server (NTRS)

    DellaCorte, C.; Lukaszewicz, V.; Valco, M. J.; Radil, K. C.; Heshmat, H.

    2000-01-01

    The performance and durability of advanced, high temperature foil air bearings are evaluated under a wide range (10-50 kPa) of loads at temperatures from 25 to 650 C. The bearings are made from uncoated nickel based superalloy foils. The foil surface experiences sliding contact with the shaft during initial start/stop operation. To reduce friction and wear, the solid lubricant coating, PS304, is applied to the shaft by plasma spraying. PS304 is a NiCr based Cr2O3 coating with silver and barium fluoride/calcium fluoride solid lubricant additions. The results show that the bearings provide lives well in excess of 30,000 cycles under all of the conditions tested. Several bearings exhibited lives in excess of 100,000 cycles. Wear is a linear function of the bearing load. The excellent performance measured in this study suggests that these bearings and the PS304 coating are well suited for advanced high temperature, oil-free turbomachinery applications.

  9. Composition optimization of self-lubricating chromium carbide-based composite coatings for use to 760 deg C

    NASA Technical Reports Server (NTRS)

    Dellacorte, C.; Sliney, H. E.

    1986-01-01

    This paper describes new compositions of self-lubricating coatings that contain chromium carbide. A bonded chromium carbide was used as the base stock because of the known excellent wear resistance and the chemical stability of chromium carbide. Additives were silver and barium fluoride/calcium fluoride eutectic. The coating constituents were treated as a ternary system consisting of: (1) the bonded carbide base material, (2) silver, and (3) the eutectic. A study to determine the optimum amounts of each constituent was performed. The various compositions were prepared by powder blending. The blended powders were then plasma sprayed onto superalloy substrates and diamond ground to the desired coating thickness. Friction and wear studies were performed at temperatures from 25 to 760 C in helium and hydrogen. A variety of counterface materials were evaluated with the objective of discovering a satisfactory metal/coating sliding combination for potential applications such as piston ring/cylinder liner couples for Stirling engines.

  10. Composition optimization of self-lubricating chromium-carbide-based composite coatings for use to 760 C

    NASA Technical Reports Server (NTRS)

    Dellacorte, Chris; Sliney, Harold E.

    1987-01-01

    This paper describes new compositions of self-lubricating coatings that contain chromium carbide. A bonded chromium carbide was used as the base stock because of the known excellent wear resistance and the chemical stability of chromium carbide. Additives were silver and barium fluoride/calcium fluoride eutectic. The coating constituents were treated as a ternary system consisting of: (1) the bonded carbide base material, (2) silver, and (3) the eutectic. A study to determine the optimum amounts of each constituent was performed. The various compositions were prepared by powder blending. The blended powders were then plasma sprayed onto superalloy substrates and diamond ground to the desired coating thickness. Friction and wear studies were performed at temperatures from 25 to 760 C in helium and hydrogen. A variety of counterface materials were evaluated with the objective of discovering a satisfactory metal/coating sliding combination for potential applications such as piston ring/cylinder liner couples for Stirling engines.

  11. Sodium fluoride-assisted modulation of anodized TiO₂ nanotube for dye-sensitized solar cells application.

    PubMed

    Yun, Jung-Ho; Ng, Yun Hau; Ye, Changhui; Mozer, Attila J; Wallace, Gordon G; Amal, Rose

    2011-05-01

    This work reports the use of sodium fluoride (in ethylene glycol electrolyte) as the replacement of hydrofluoric acid and ammonium fluoride to fabricate long and perpendicularly well-aligned TiO₂ nanotube (TNT) (up to 21 μm) using anodization. Anodizing duration, applied voltage and electrolyte composition influenced the geometry and surface morphologies of TNT. The growth mechanism of TNT is interpreted by analyzing the current transient profile and the total charge density generated during anodization. The system with low water content (2 wt %) yielded a membrane-like mesoporous TiO₂ film, whereas high anodizing voltage (70 V) resulted in the unstable film of TNT arrays. An optimized condition using 5 wt % water content and 60 V of anodizing voltage gave a stable array of nanotube with controllable length and pore diameter. Upon photoexcitation, TNTs synthesized under this condition exhibited a slower charge recombination rate as nanotube length increased. When made into cis-diisothiocyanato-bis(2,2̀-bipyridyl-4,4̀-dicarboxylato) ruthenium(II) bis (tetrabutyl-ammonium)(N719) dye-sensitized solar cells, good device efficiency at 3.33 % based on the optimized TNT arrays was achieved with longer electron time compared with most mesoporous TiO₂ films.

  12. Tribological properties of PM212: A high-temperature, self-lubricating, powder metallurgy composite

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher; Sliney, Harold E.

    1989-01-01

    This paper describes a research program to develop and evaluate a new high temperature, self-lubricating powder metallurgy composite, PM212. PM212 has the same composition as the plasma-sprayed coating, PS212, which contains 70 wt percent metal-bonded chromium carbide, 15 wt percent silver and 15 wt percent barium fluoride/calcium fluoride eutectic. The carbide acts as a wear resistant matrix and the silver and fluorides act as low and high temperature lubricants, respectively. The material is prepared by sequential cold press, cold isostatic pressing and sintering techniques. In this study, hemispherically tipped wear pins of PM212 were prepared and slid against superalloy disks at temperatures from 25 to 850 C in air in a pin-on-disk tribometer. Friction coefficients range from 0.29 to 0.38 and the wear of both the composite pins and superalloy disks was moderate to low in the 10(exp -5) to 10(exp -6) cubic mm/N-m range. Preliminary tests indicate that the material has a compressive strength of at least 130 MPa over the entire temperature range of 25 to 900 C. This material has promise for use as seal inserts, bushings, small inside diameter parts and other applications where plasma-sprayed coatings are impractical or too costly.

  13. Tribological properties of PM212 - A high temperature, self-lubricating, powder metallurgy composite

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher; Sliney, Harold E.

    1990-01-01

    This paper describes a research program to develop and evaluate a new high temperature, self-lubricating powder metallurgy composite, PM212. PM212 has the same composition as the plasma-sprayed coating, PS212, which contains 70 wt percent metal-bonded chromium carbide, 15 wt percent silver and 15 wt percent barium fluoride/calcium fluoride eutectic. The carbide acts as a wear resistant matrix and the silver and fluorides act as low and high temperature lubricants, respectively. The material is prepared by sequential cold press, cold isostatic pressing and sintering techniques. In this study, hemispherically tipped wear pins of PM212 were prepared and slid against superalloy disks at temperatures from 25 to 850 C in air in a pin-on-disk tribometer. Friction coefficients range from 0.29 to 0.38 and the wear of both the composite pins and superalloy disks was moderate to low in the 10(exp -5) to 10(exp -6) cubic mm/N-m range. Preliminary tests indicate that the material has a compressive strength of at least 130 MPa over the entire temperature range of 25 to 900 C. This material has promise for use as seal inserts, bushings, small inside diameter parts and other applications where plasma-sprayed coatings are impractical or too costly.

  14. Spectroscopic study of trivalent praseodymium in barium yttrium fluoride

    NASA Astrophysics Data System (ADS)

    Bowlby, Brian Edward

    1998-09-01

    This work investigates the spectroscopic properties of trivalent praseodymium (Pr3+) in barium yttrium fluoride (BaY2F8). Two doping concentrations were studied: BaY2F8:Pr3+ (.3%) and BaY2F8:Pr3+ (1%). Absorption spectra were taken at 77K and 300K and these were then used to calculate the Judd-Ofelt coefficients for both samples. These coefficients were then used to calculate the theoretical lifetimes and radiative branching ratios for all manifolds. Continuous luminescence spectra and lifetime measurements were also performed, and from these, experimentally determined values for the branching ratio and lifetimes were determined. These were then compared to their theoretical counterparts. It was found that while the theory gave values that were qualitatively correct, the quantitative correlation between theory and experiment shows the complexity of the physical reality and the difficulty of synthesizing an encompassing theoretical model. Absorption spectra and continuous luminescence spectra were also used to determine the energy levels of all manifolds in both samples. A total of 59 energy levels in 11 manifolds were identified in the BaY2F8:Pr3+ (1%) sample, while 51 levels in 11 manifolds were identified in the BaY2F8:Pr3+ (.3%) sample. Finally, the effects of temperature on the line width and line position for several radiative transitions was studied. It was found that while most transitions exhibited the expected broadening and shifting towards longer wavelengths at higher temperatures (a 'red shift'), the transition from the 3P0 level to the 3H4 ground state showed a shift towards shorter wavelengths at higher temperature (a 'blue shift'). Again this highlights the complexity of the ion- host interaction.

  15. Spectral engineering of optical fiber through active nanoparticle doping

    NASA Astrophysics Data System (ADS)

    Lindstrom-James, Tiffany

    The spectral engineering of optical fiber is a method of intentional doping of the core region in order to absorb/emit specific wavelengths of light therby providing enhanced performance over current fibers. Efforts here focused on developing an understanding of optically active nanoparticles based on alkaline earth fluorides that could be easily and homogeneously incorporated into the core of a silica based optical fiber preform and result in efficient and tailorable spectral emissions. Doped and undoped calcium, strontium and barium fluoride nanoparticles were successfully synthesized and characterized for their physical, chemical, and optical behavior. Distinct spectroscopic differences as a result of different host materials, varying rare earth doping levels and processing conditions, indicated the ability to influence the spectral behavior of the doped nanoparticle. By using photoluminescence to predict diffusion behavior, the application of a simple one dimensional model for diffusion provided a method for predicting the diffusion coefficient of europium ions in alkaline earth fluorides with order of magnitude accuracy. Modified chemical vapor deposition derived silica preforms were individually solution doped with europium doped alkaline earth fluoride nanoparticles. By using the rare earth doped alkaline earth fluoride nanoparticles as the dopant materials in the core of optical fiber preforms, the resultant optical properties of the glass were significantly influenced by their presence in the core. The incorporation of these rare earth doped alkaline earth fluoride nanoparticles was found to significantly influence the local chemical and structural environment about the rare earth ion, demonstrated homogeneity and uniform distribution of the rare earth dopant and resulted in specifically unique spectral behavior when compared to conventional doping methods. A more detailed structural model of the doped core glass region has been developed based on the spectral behavior of these active fiber preforms. It has been shown that rare earth doping of alkaline earth fluoride nanoparticles provides a material which can be 'tuned' to specific applications through the use of different host materials, processing conditions and doping levels of the rare earth and when used as dopant materials for active optical fibers, provides a means to tailor the optical behavior.

  16. Formation of TiO2 nanotube arrays in KOH added fluoride-ethylene glycol (EG) electrolyte and its photoelectrochemical response

    NASA Astrophysics Data System (ADS)

    Nyein, Nyein; Lockman, Zainovia; Matsuda, Astunori; Kawamura, Go; Tan, Wai Kian; Oo, Than Zaw

    2016-07-01

    In this study, highly ordered TiO2 nanotube arrays were prepared by anodic oxidation of titanium foil in fluoride -EG electrolyte containing a small amount of potassium hydroxide, KOH at 60 V for 30 min. This electrolyte resulted in the formation of long nanotubes with an average length of 10 µm and diameter of 170 nm. For comparison, TiO2 nanotubes anodized in H2O added EG electrolyte which produces short nanotubes with an average tube length of 5 µm and diameter of 170 nm. It appears that the addition of KOH into the fluoride EG electrolyte accelerated the formation of the TiO2 nanotubes as it is believed that the chemical dissolution at the tips of the nanotubes is suppressed. Highly ordered TiO2 nanotubes anodized in KOH added EG electrolyte exhibited the photocurrent density of 2 mA/cm2, which is significantly higher than H2O added sample (1.5 mA/cm2).

  17. Radio frequency surface resistance of Tl-Ba-Ca-Cu-O films on metal and single-crystal substrates

    NASA Astrophysics Data System (ADS)

    Arendt, P. N.; Reeves, G. A.; Elliott, N. E.; Cooke, D. W.; Gray, E. R.; Houlton, R. J.; Brown, D. R.

    1990-01-01

    Films of Tl-Ba-Ca-Cu were dc magnetron sputtered from a single multielement target. The films were deposited onto substrates of: (1) magnesium oxide, (2) a silver based alloy (Consil 995), (3) a nickel based alloy (Haynes 230), and (4) buffer layers of barium fluoride or copper oxide on Consil. To form superconducting phases, post-deposition anneals were made on these films using an alumina crucible with an over pressure of thallium and flowing oxygen. After annealing, the film phases were determined using x-ray diffraction. The film surface resistances (Rs) were measured at 22 GHz in a TE011 cavity.

  18. Facile fabrication of highly ordered poly(vinylidene fluoride-trifluoroethylene) nanodot arrays for organic ferroelectric memory

    NASA Astrophysics Data System (ADS)

    Fang, Huajing; Yan, Qingfeng; Geng, Chong; Chan, Ngai Yui; Au, Kit; Yao, Jianjun; Ng, Sheung Mei; Leung, Chi Wah; Li, Qiang; Guo, Dong; Wa Chan, Helen Lai; Dai, Jiyan

    2016-01-01

    Nano-patterned ferroelectric materials have attracted significant attention as the presence of two or more thermodynamically equivalent switchable polarization states can be employed in many applications such as non-volatile memory. In this work, a simple and effective approach for fabrication of highly ordered poly(vinylidene fluoride-trifluoroethylene) P(VDF-TrFE) nanodot arrays is demonstrated. By using a soft polydimethylsiloxane mold, we successfully transferred the 2D array pattern from the initial monolayer of colloidal polystyrene nanospheres to the imprinted P(VDF-TrFE) films via nanoimprinting. The existence of a preferred orientation of the copolymer chain after nanoimprinting was confirmed by Fourier transform infrared spectra. Local polarization switching behavior was measured by piezoresponse force microscopy, and each nanodot showed well-formed hysteresis curve and butterfly loop with a coercive field of ˜62.5 MV/m. To illustrate the potential application of these ordered P(VDF-TrFE) nanodot arrays, the writing and reading process as non-volatile memory was demonstrated at a relatively low voltage. As such, our results offer a facile and promising route to produce arrays of ferroelectric polymer nanodots with improved piezoelectric functionality.

  19. Utilization of Infrared Fiber Optic in the Automotive Industry

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.; Brantley, Lott W. (Technical Monitor)

    2001-01-01

    Fiber optics are finding a place in the automotive industry. Illumination is the primary application today. Soon, however, fiber optics will be used for data communications and sensing applications. Silica fiber optics and plastic fibers are sufficient for illumination and communication applications however, sensing applications involving high temperature measurement and remote gas analysis would benefit from the use of infrared fiber optics. Chalcogonide and heavy metal fluoride glass optical fibers are two good candidates for these applications. Heavy metal fluoride optical fibers are being investigated by NASA for applications requiring transmission in the infrared portion of the electromagnetic spectrum. Zirconium-Barium-Lanthanum-Aluminum-Sodium-Fluoride (ZBLAN) is one such material which has been investigated. This material has a theoretical attenuation coefficient 100 times lower than that of silica and transmits into the mid-IR. However, the measured attenuation coefficient is higher than silica due to impurities and crystallization. Impurities can be taken care of by utilizing cleaner experimental protocol. It has been found that crystallization can be suppressed by processing in reduced gravity. Fibers processed in reduced gravity on the KC135 reduced gravity aircraft were found to be free of crystals while those processed on the ground were found to have crystals. These results will be presented along with plans for producing continuous lengths of ZBLAN optical fiber on board the International Space Station.

  20. Sputtered silver films to improve chromium carbide based solid lubricant coatings for use to 900 C

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher; Sliney, Harold E.; Deadmore, Daniel L.

    1988-01-01

    Thin silver films, 250 to 3500 A thick, were sputtered onto PS200, a plasma sprayed, chromium carbide based solid lubricant coating, to reduce run-in wear and improve tribological properties. The coating contains bonded chromium carbide as the wear resistant base stock with silver and barium fluoride/calcium fluoride eutectic added as low and high temperature lubricants, respectively. Potential applications for the PS200 coating are cylinder wall/piston ring lubrication for Stirling engines and foil bearing journal lubrication. In this preliminary program, the silver film overlay thickness was optimized based on tests using a pin-on-disk tribometer. The friction and wear studies were performed in a helium atmosphere at temperatures from 25 to 760 C with a sliding velocity of 2.7 m/s under a 4.9 N load. Films between 1000 and 1500 A provide the best lubrication of the counterface material. The films enrich the sliding surface with lubricant and reduce the initial abrasiveness of the as ground, plasma-sprayed coating surface, thus reducing wear.

  1. A new chromium carbide-based tribological coating for use to 900 C with particular reference to the Stirling engine

    NASA Technical Reports Server (NTRS)

    Sliney, Harold E.

    1986-01-01

    A new chromium carbide-based coating (PS 200) is described. This coating is shown to have good friction and wear properties over a wide temperature range. A nickel alloy-bonded chromium carbide coating was used as a baseline material for comparison with experimentally formulated coatings. Coatings were plasma sprayed onto metal disks, then diamond ground to a thickness of 0.025 cm. Friction and wear were determined using a pin on disk tribometer at temperatures from 25 to 900 C in hydrogen, helium, and air. Pin materials included several metallic alloys and silicon carbide. It was found that appropriate additions of metallic silver and of barium fluoride/calcium fluoride eutectic to the baseline carbide composition significantly reduced friction coefficients while preserving, and in some cases, even enhancing wear resistance. The results of this study demonstrate that PS 200 is a promising coating composition to consider for high temperature aerospace and advanced heat engine applications. The excellent results in hydrogen make this coating of particular interest for use in the Stirling engine.

  2. Sputtered silver films to improve chromium carbide based solid lubricant coatings for use to 900 C

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher; Sliney, Harold E.; Deadmore, Daniel L.

    1988-01-01

    Thin silver films, 250 to 3500 A thick, were sputtered onto PS200, a plasma sprayed, chromium carbide based solid lubricant coating, to reduce run-in wear and improve tribological properties. The coating contains bonded chromium carbide as the wear resistant base stock with silver and barium fluoride/calcium fluoride eutectic added as low and high temperature lubricants respectively. Potential applications for the PS200 coating are cylinder wall/piston ring lubrication for Stirling engines and foil bearing journal lubrication. In this preliminary program, the silver film overlay thickness was optimized based on tests using a pin-on-disk tribometer. The friction and wear studies were performed in a helium atmosphere at temperatures from 25 to 760 C with a sliding velocity of 2.7 m/s under a 4.9 N load. Films between 1000 and 1500 A provide the best lubrication of the counterface material. The films enrich the sliding surface with lubricant and reduce the initial abrasiveness of the as ground, plasma-sprayed coating surface, thus reducing wear.

  3. A new chromium carbide-based tribological coating for use to 900 deg C with particular reference to the Stirling engine

    NASA Technical Reports Server (NTRS)

    Sliney, H. E.

    1986-01-01

    A new chromium carbide-based coating (PS 200) is described. This coating is shown to have good friction and wear properties over a wide temperature range. A nickel alloy-bonded chromium carbide coating was used as a baseline material for comparison with experimental formulated coatings. Coatings were plasma sprayed onto metal disks, then diamond ground to a thickness of 0.025 cm. Friction and wear were determined using a pin on disk tribometer at temperatures from 25 to 900 C in hydrogen, helium, and air. Pin materials included several metallic alloys and silicon carbide. It was found that appropriate additions of metallic silver and of barium fluoride/calcium fluoride eutectic to the baseline carbide composition significantly reduced friction coefficients while preserving, and in some cases, even enhancing wear resistance. The results of this study demonstrate that PS 200 is a promising coating composition to consider for high temperature aerospace and advanced heat engine applications. The excellent results in hydrogen make this coating of particular interest for use in the Stirling engine.

  4. Heterogeneous Mixtures as NLO Christiansen Filters for Optical Limiting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Exarhos, Gregory J.; Ferris, Kim F.; Samuels, William D.

    Mixtures of two non-absorbing and index-matched materials with contrasting nonlinear optical response have been shown to optically limit above a critical fluence of pulsed nanosecond laser light. Under these conditions, index mismatch is induced between the disparate phases leading to strong Tyndall scattering. The effect has been demonstrated previously by the authors in both solid-liquid mixtures (hexadecane and calcium fluoride), and surfactant-stabilized liquid-liquid emulsions consisting of dichloroethane as the organic phase and a concentrated aqueous phase of sodium thiocyanate (NaSCN). Materials used in these studies exhibit low absorption coefficients over extended wavelength regions allowing for a broadband response of themore » limiter. Recently, limiting has been observed at 532 nm in a polymer composite consisting of barium fluoride and poly-(n-butyl acrylate). A modified open-aperture z-scan method was used to quantify optical limiter performance in this system. Modeling studies provide the basis for designing optical limiters based upon this light scattering mechanism and show the importance of size resonance and constituent optical properties on limiter performance.« less

  5. Methods for collection and analysis of geopressured geothermal and oil field waters

    USGS Publications Warehouse

    Lico, Michael S.; Kharaka, Yousif K.; Carothers, William W.; Wright, Victoria A.

    1982-01-01

    Present methods are described for the collection, preservation, and chemical analysis of waters produced from geopressured geothermal and petroleum wells. Detailed procedures for collection include precautions and equipment necessary to ensure that the sample is representative of the water produced. Procedures for sample preservation include filtration, acidification, dilution for silica, methyl isobutyl ketone (MIBK) extraction of aluminum, addition of potassium permanganate to preserve mercury, and precipitation of carbonate species as strontium carbonate for stable carbon isotopes and total dissolved carbonate analysis. Characteristics determined at the well site are sulfide, pH, ammonia, and conductivity. Laboratory procedures are given for the analysis of lithium, sodium, potassium, rubidium, cesium, magnesium, calcium, strontium, barium, iron, manganese, zinc, lead, aluminum, .and mercury by atomic absorption and flame emission spectroscopy. Chloride is determined by silver nitrate titration and fluoride by ion-specific electrode. Bromide and iodide concentrations are determined by the hypochlorite oxidation method. Sulfate is analyzed by titration using barium chloride with thorin indicator after pretreatment with alumina. Boron and silica are determined colorimetrically by the carmine and molybdate-blue methods, respectively. Aliphatic acid anions (C2 through C5) are determined by gas chromatography after separation and concentration in a chloroform-butanol mixture.

  6. FY07 LDRD Final Report Neutron Capture Cross-Section Measurements at DANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, W; Agvaanluvsan, U; Wilk, P

    2008-02-08

    We have measured neutron capture cross sections intended to address defense science problems including mix and the Quantification of Margins and Uncertainties (QMU), and provide details about statistical decay of excited nuclei. A major part of this project included developing the ability to produce radioactive targets. The cross-section measurements were made using the white neutron source at the Los Alamos Neutron Science Center, the detector array called DANCE (The Detector for Advanced Neutron Capture Experiments) and targets important for astrophysics and stockpile stewardship. DANCE is at the leading edge of neutron capture physics and represents a major leap forward inmore » capability. The detector array was recently built with LDRD money. Our measurements are a significant part of the early results from the new experimental DANCE facility. Neutron capture reactions are important for basic nuclear science, including astrophysics and the statistics of the {gamma}-ray cascades, and for applied science, including stockpile science and technology. We were most interested in neutron capture with neutron energies in the range between 1 eV and a few hundred keV, with targets important to basic science, and the s-process in particular. Of particular interest were neutron capture cross-section measurements of rare isotopes, especially radioactive isotopes. A strong collaboration between universities and Los Alamos due to the Academic Alliance was in place at the start of our project. Our project gave Livermore leverage in focusing on Livermore interests. The Lawrence Livermore Laboratory did not have a resident expert in cross-section measurements; this project allowed us to develop this expertise. For many radionuclides, the cross sections for destruction, especially (n,{gamma}), are not well known, and there is no adequate model that describes neutron capture. The modeling problem is significant because, at low energies where capture reactions are important, the neutron reaction cross sections show resonance behavior or follow 1/v of the incident neutrons. In the case of odd-odd nuclei, the modeling problem is particularly difficult because degenerate states (rotational bands) present in even-even nuclei have separated in energy. Our work included interpretation of the {gamma}-ray spectra to compare with the Statistical Model and provides information on level density and statistical decay. Neutron capture cross sections are of programmatic interest to defense sciences because many elements were added to nuclear devices in order to determine various details of the nuclear detonation, including fission yields, fusion yields, and mix. Both product nuclei created by (n,2n) reactions and reactant nuclei are transmuted by neutron capture during the explosion. Very few of the (n,{gamma}) cross sections for reactions that create products measured by radiochemists have ever been experimentally determined; most are calculated by radiochemical equivalences. Our new experimentally measured capture cross sections directly impact our knowledge about the uncertainties in device performances, which enhances our capability of carrying out our stockpile stewardship program. Europium and gadolinium cross sections are important for both astrophysics and defense programs. Measurements made prior to this project on stable europium targets differ by 30-40%, which was considered to be significantly disparate. Of the gadolinium isotopes, {sup 151}Gd is important for stockpile stewardship, and {sup 153}Gd is of high interest to astrophysics, and nether of these (radioactive) gadolinium (n,{gamma}) cross sections have been measured. Additional stable gadolinium isotopes, including {sup 157,160}Gd are of interest to astrophysics. Historical measurements of gadolinium isotopes, including {sup 152,154}Gd, had disagreements similar to the 30-40% disagreements found in the historical europium data. Actinide capture cross section measurements are important for both Stockpile Stewardship and for nuclear forensics. We focused on the {sup 242m}Am(n,{gamma}) measurement, as there was no existing capture measurement for this isotope. The cross-section measurements (cross section vs. E{sub n}) were made at the Detector for Advanced Neutron Capture Experiments. DANCE is comprised of a highly segmented array of barium fluoride (BaF{sub 2}) crystals specifically designed for neutron capture-gamma measurements, using small radioactive targets (less than one milligram). A picture of half the array, along with a photo of one crystal, is shown in Fig. 1. DANCE provides the world's leading capability for measurements of neutron capture cross sections with radioactive targets. The DANCE is a 4{pi} calorimeter and uses the intense spallation neutron source the Lujan Center at the Los Alamos National Laboratory. The detector array consists of 159 barium fluoride crystals arranged in a sphere around the target.« less

  7. Color change of composite resins subjected to accelerated artificial aging.

    PubMed

    Tornavoi, Denise Cremonezzi; Agnelli, José Augusto Marcondes; Panzeri, Heitor; Dos Reis, Andréa Cândido

    2013-01-01

    The aim of this study was to evaluate the influence of accelerated artificial aging (AAA) on the color change of composite resins used in dentistry. Three composite resins were evaluated: Two microhybrids and one hybrid of higher viscosity, with different amounts and sizes of filler particles, shades C2 and B2. A total of 54 specimens were obtained (18 for each composite resin), made of a Teflon matrix (15 mm in diameter and 2 mm in height). The color measurements were obtained with a Spectrophotometer, (PCB 6807 BYK Gardner) before and after AAA. Data were submitted to the Kolmogorov-Smirnov test (α >0.05), ANOVA and Tukey test (α <0.05). After statistical analysis, the color difference among composite resins with the same shades was analyzed. All composite resins showed unacceptable color changes after AAA (ΔE > 3). Considering the variable ∆E, it was observed that the color tone C2 was already statistically different for the microhybrid composite resin prior to AAA (P < 0.05) and in shade B2 for hybrid of higher viscosity and microhybrid with barium glass fluoride aluminum and silica dioxide (P < 0.01). After this process, a statistically significant difference was observed only for shade B2 between microhybrid composite resins (P < 0.01) and for hybrid of higher viscosity and microhybrid with barium glass fluoride aluminum and silica dioxide (P < 0.05). Regarding the color difference within a same composite resin group, before aging the composite resin hybrid of higher viscosity B2 showed the highest color variation rate and microhybrid with zirconium/silica C2 showed the lowest. All composite resins presented unacceptable color changes after 382 h of aging and different composite resins with same hue, presented different colors before being subjected to the aging process (B2 and C2) and after (B2). It was also observed color difference within a group of the same composite resin and same hue.

  8. Arrays of membrane isolated yttrium-barium-copper-oxide kinetic inductance bolometers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindeman, M. A., E-mail: mark.a.lindeman@jpl.nasa.gov; Bonetti, J. A.; Bumble, B.

    We are developing of arrays of membrane isolated resonator-bolometers, each with a kinetic inductance device (KID) to measure the temperature of the membrane. The KIDs are fabricated out of the high temperature superconductor YBCO to allow operation at relatively high temperatures. The bolometers are designed to offer higher sensitivity than sensors operating at 300 K, but they require less expensive and lighter weight cooling than even more sensitive conventional superconducting detectors operating at lower temperatures. The bolometer arrays are applicable as focal planes in infrared imaging spectrometers, such as for planetary science missions or earth observing satellites. We describe the devicesmore » and present measurements of their sensitivity.« less

  9. Self-organized nitrogen and fluorine co-doped titanium oxide nanotube arrays with enhanced visible light photocatalytic performance.

    PubMed

    Li, Qi; Shang, Jian Ku

    2009-12-01

    Self-organized nitrogen and fluorine co-doped titanium oxide (TiONF) nanotube arrays were created by anodizing titanium foil in a fluoride and ammoniate-based electrolyte, followed by calcination of the amorphous nanotube arrays under a nitrogen protective atmosphere for crystallization. TiONF nanotube arrays were found to have enhanced visible light absorption capability and photodegradation efficiency on methylene blue under visible light illumination over the TiO(2) nanotube arrays. The enhancement was dependent on both the nanotube structural architecture and the nitrogen and fluorine co-doping effect. TiONF nanotube arrays promise a wide range of technical applications, especially for environmental applications and solar cell devices.

  10. X-ray imaging using digital cameras

    NASA Astrophysics Data System (ADS)

    Winch, Nicola M.; Edgar, Andrew

    2012-03-01

    The possibility of using the combination of a computed radiography (storage phosphor) cassette and a semiprofessional grade digital camera for medical or dental radiography is investigated. We compare the performance of (i) a Canon 5D Mk II single lens reflex camera with f1.4 lens and full-frame CMOS array sensor and (ii) a cooled CCD-based camera with a 1/3 frame sensor and the same lens system. Both systems are tested with 240 x 180 mm cassettes which are based on either powdered europium-doped barium fluoride bromide or needle structure europium-doped cesium bromide. The modulation transfer function for both systems has been determined and falls to a value of 0.2 at around 2 lp/mm, and is limited by light scattering of the emitted light from the storage phosphor rather than the optics or sensor pixelation. The modulation transfer function for the CsBr:Eu2+ plate is bimodal, with a high frequency wing which is attributed to the light-guiding behaviour of the needle structure. The detective quantum efficiency has been determined using a radioisotope source and is comparatively low at 0.017 for the CMOS camera and 0.006 for the CCD camera, attributed to the poor light harvesting by the lens. The primary advantages of the method are portability, robustness, digital imaging and low cost; the limitations are the low detective quantum efficiency and hence signal-to-noise ratio for medical doses, and restricted range of plate sizes. Representative images taken with medical doses are shown and illustrate the potential use for portable basic radiography.

  11. Multiple inorganic toxic substances contaminating the groundwater of Myingyan Township, Myanmar: arsenic, manganese, fluoride, iron, and uranium.

    PubMed

    Bacquart, Thomas; Frisbie, Seth; Mitchell, Erika; Grigg, Laurie; Cole, Christopher; Small, Colleen; Sarkar, Bibudhendra

    2015-06-01

    In South Asia, the technological and societal shift from drinking surface water to groundwater has resulted in a great reduction of acute diseases due to water borne pathogens. However, arsenic and other naturally occurring inorganic toxic substances present in groundwater in the region have been linked to a variety of chronic diseases, including cancers, heart disease, and neurological problems. Due to the highly specific symptoms of chronic arsenic poisoning, arsenic was the first inorganic toxic substance to be noticed at unsafe levels in the groundwater of West Bengal, India and Bangladesh. Subsequently, other inorganic toxic substances, including manganese, uranium, and fluoride have been found at unsafe levels in groundwater in South Asia. While numerous drinking water wells throughout Myanmar have been tested for arsenic, relatively little is known about the concentrations of other inorganic toxic substances in Myanmar groundwater. In this study, we analyzed samples from 18 drinking water wells (12 in Myingyan City and 6 in nearby Tha Pyay Thar Village) and 2 locations in the Ayeyarwaddy River for arsenic, boron, barium, beryllium, cadmium, cobalt, chromium, copper, fluoride, iron, mercury, manganese, molybdenum, nickel, lead, antimony, selenium, thallium, uranium, vanadium, and zinc. Concentrations of arsenic, manganese, fluoride, iron, or uranium exceeded health-based reference values in most wells. In addition, any given well usually contained more than one toxic substance at unsafe concentrations. While water testing and well sharing could reduce health risks, none of the wells sampled provide water that is entirely safe with respect to inorganic toxic substances. It is imperative that users of these wells, and users of other wells that have not been tested for multiple inorganic toxic substances throughout the region, be informed of the need for drinking water testing and the health consequences of drinking water contaminated with inorganic toxic substances. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. High-MTF hybrid ferroelectric IRFPA

    NASA Astrophysics Data System (ADS)

    Evans, Scott B.; Hayden, Terrence

    1998-07-01

    Low cost, uncooled hybrid infrared focal plane arrays (IRFPA's) are in full-scale production at Raytheon Systems Company (RSC), formerly Texas Instruments Defense Systems and Electronics Group. Detectors consist of reticulated ceramic barium strontium titanate (BST) arrays of 320 X 240 pixels on 48.5 micrometer pitch. The principal performance shortcoming of the hybrid arrays has been low MTF due to thermal crosstalk between pixels. In the past two years, significant improvements have been made to increase MTF making hybrids more competitive in performance with monolithic arrays. The improvements are (1) the reduction of the thickness of the IR absorbing layer electrode that maintains electrical continuity and increases thermal isolation between pixels, (2) reduction of the electrical crosstalk from the ROIC, and (3) development of a process to increase the thermal path-length between pixels called 'elevated optical coat.' This paper describes all three activities and their efficacy. Also discussed is the uncooled IRFPA production capability at RSC.

  13. Influence of anodization parameters on the morphology of TiO 2 nanotube arrays

    NASA Astrophysics Data System (ADS)

    Omidvar, Hamid; Goodarzi, Saba; Seif, Ahmad; Azadmehr, Amir R.

    2011-07-01

    TiO 2 nanotube arrays can be fabricated by electrochemical anodization in organic and inorganic electrolytes. Morphology of these nanotube arrays changes when anodization parameters such as applied voltage, type of electrolyte, time and temperature are varied. Nanotube arrays fabricated by anodization of commercial titanium in electrolytes containing NH 4F solution and either sulfuric or phosphoric acid were studied at room temperature; time of anodization was kept constant. Applied voltage, fluoride ion concentration, and acid concentrations were varied and their influences on TiO 2 nanotubes were investigated. The current density of anodizing was recorded by computer controlled digital multimeter. The surface morphology (top-view) of nanotube arrays were observed by SEM. The nanotube arrays in this study have inner diameters in range of 40-80 nm.

  14. Hydrothermally synthesized barium fluoride nanocubes for thermoluminescence dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhadane, Mahesh S.; Dahiwale, S. S.; Bhoraskar, V. N.

    2016-05-23

    In this work, we report a hydrothermally synthesized Dy doped BaF{sub 2} (BaF{sub 2}:Dy) nanocubes and its Thermoluminescence studies. The synthesized BaF{sub 2}:Dy samples was found to posses FCC structure and having average size ~ 60-70 nm, as revealed through X-Ray Diffraction. Cubical morphology having size ~90 nm was observed from TEM analysis. The {sup 60}Co γ- ray irradiated BaF{sub 2}:Dy TL dosimetric experiments shows a pre-dominant single glow peak at 153 °C, indicating a single level trap present as a metastable state. Furthermore, BaF{sub 2}:Dy nanophosphor shows a sharp linear response from 10 Gy to 3 kGy, thus it can be applicablemore » as a gamma dosimeter.« less

  15. Sheet plastic filters for solar cells

    NASA Technical Reports Server (NTRS)

    Wizenick, R. J.

    1972-01-01

    Poly(vinylidene fluoride) (PVF) film protects solar cells on Mars surface from radiation and prevents degradation of solar cell surfaces by Martian dust storms. PVF films may replace glass or quartz windows on solar cell arrays used to generate power on earth.

  16. Toward self-assembled ferroelectric random access memories: hard-wired switching capacitor arrays with almost Tb/in.(2) densities.

    PubMed

    Evans, Paul R; Zhu, Xinhau; Baxter, Paul; McMillen, Mark; McPhillips, John; Morrison, Finlay D; Scott, James F; Pollard, Robert J; Bowman, Robert M; Gregg, J Marty

    2007-05-01

    We report on the successful fabrication of arrays of switchable nanocapacitors made by harnessing the self-assembly of materials. The structures are composed of arrays of 20-40 nm diameter Pt nanowires, spaced 50-100 nm apart, electrodeposited through nanoporous alumina onto a thin film lower electrode on a silicon wafer. A thin film ferroelectric (both barium titanate (BTO) and lead zirconium titanate (PZT)) has been deposited on top of the nanowire array, followed by the deposition of thin film upper electrodes. The PZT nanocapacitors exhibit hysteresis loops with substantial remnant polarizations, while although the switching performance was inferior, the low-field characteristics of the BTO nanocapacitors show dielectric behavior comparable to conventional thin film heterostructures. While registration is not sufficient for commercial RAM production, this is nevertheless an embryonic form of the highest density hard-wired FRAM capacitor array reported to date and compares favorably with atomic force microscopy read-write densities.

  17. High-Temperature Solid Lubricants Developed by NASA Lewis Offer Virtually "Unlimited Life" for Oil-Free Turbomachinery

    NASA Technical Reports Server (NTRS)

    DellaCorte, Christopher; Valco, Mark J.

    1999-01-01

    The NASA Lewis Research Center is capitalizing on breakthroughs in foil air bearing performance, tribological coatings, and computer analyses to formulate the Oil-free Turbomachinery Program. The program s long-term goal is to develop an innovative, yet practical, oil-free aeropropulsion gas turbine engine that floats on advanced air bearings. This type of engine would operate at higher speeds and temperatures with lower weight and friction than conventional oil-lubricated engines. During startup and shutdown, solid lubricant coatings are required to prevent wear in such engines before the self-generating air-lubrication film develops. NASA s Tribology Branch has created PS304, a chrome-oxide-based plasma spray coating specifically tailored for shafts run against foil bearings. PS304 contains silver and barium fluoride/calcium fluoride eutectic (BaF2/CaF2) lubricant additives that, together, provide lubrication from cold start temperatures to over 650 C, the maximum use temperature for foil bearings. Recent lab tests show that bearings lubricated with PS304 survive over 100 000 start-stop cycles without experiencing any degradation in performance due to wear. The accompanying photograph shows a test bearing after it was run at 650 C. The rubbing process created a "polished" surface that enhances bearing load capacity.

  18. Ultra-Sensitive Strain Sensor Based on Flexible Poly(vinylidene fluoride) Piezoelectric Film

    NASA Astrophysics Data System (ADS)

    Lu, Kai; Huang, Wen; Guo, Junxiong; Gong, Tianxun; Wei, Xiongbang; Lu, Bing-Wei; Liu, Si-Yi; Yu, Bin

    2018-03-01

    A flexible 4 × 4 sensor array with 16 micro-scale capacitive units has been demonstrated based on flexible piezoelectric poly(vinylidene fluoride) (PVDF) film. The piezoelectricity and surface morphology of the PVDF were examined by optical imaging and piezoresponse force microscopy (PFM). The PFM shows phase contrast, indicating clear interface between the PVDF and electrode. The electro-mechanical properties show that the sensor exhibits excellent output response and an ultra-high signal-to-noise ratio. The output voltage and the applied pressure possess linear relationship with a slope of 12 mV/kPa. The hold-and-release output characteristics recover in less than 2.5 μs, demonstrating outstanding electro-mechanical response. Additionally, signal interference between the adjacent arrays has been investigated via theoretical simulation. The results show the interference reduces with decreasing pressure at a rate of 0.028 mV/kPa, highly scalable with electrode size and becoming insignificant for pressure level under 178 kPa.

  19. Ultra-Sensitive Strain Sensor Based on Flexible Poly(vinylidene fluoride) Piezoelectric Film.

    PubMed

    Lu, Kai; Huang, Wen; Guo, Junxiong; Gong, Tianxun; Wei, Xiongbang; Lu, Bing-Wei; Liu, Si-Yi; Yu, Bin

    2018-03-14

    A flexible 4 × 4 sensor array with 16 micro-scale capacitive units has been demonstrated based on flexible piezoelectric poly(vinylidene fluoride) (PVDF) film. The piezoelectricity and surface morphology of the PVDF were examined by optical imaging and piezoresponse force microscopy (PFM). The PFM shows phase contrast, indicating clear interface between the PVDF and electrode. The electro-mechanical properties show that the sensor exhibits excellent output response and an ultra-high signal-to-noise ratio. The output voltage and the applied pressure possess linear relationship with a slope of 12 mV/kPa. The hold-and-release output characteristics recover in less than 2.5 μs, demonstrating outstanding electro-mechanical response. Additionally, signal interference between the adjacent arrays has been investigated via theoretical simulation. The results show the interference reduces with decreasing pressure at a rate of 0.028 mV/kPa, highly scalable with electrode size and becoming insignificant for pressure level under 178 kPa.

  20. The experimental evaluation and application of high-temperature solid lubricants. Ph.D. Thesis - Case Western Reserve Univ., 1989 Final Report

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher

    1990-01-01

    A research program is described which developes an understanding of high-temperature solid lubrication and experimental techniques through the development of a composite lubricant coating system. The knowledge gained through this research was then applied to a specific engineering challenge, the tribology of a sliding seal for hypersonic flight vehicles. The solid lubricant coating is a chromium carbide based composite combined with silver, which acts as a low temperature lubricant, and barium fluoride/calcium fluoride eutectic, which acts as a high-temperature lubricant. This composite coating provides good wear resistance and low friction for sliding contacts from room temperature to over 900 C in reducing or oxidative environments. The specific research on this coating included a composition screening using a foil gas bearing test rig and the use of thin silver films to reduce initial wear using a pin-on-disk test rig. The chemical stability of the materials used was also addressed. This research indicated that soft metallic films and materials which become soft at elevated temperatures are potentially good lubricants. The general results from the experiments with the model solid lubricant coating were then applied to a sliding seal design concept. This seal design requires that a braided ceramic fabric slide against a variety of metal counterface materials at temperatures from 25 to 850 C in an oxidative environment. A pin-on-disk tribometer was used to evaluate the tribological properties of these materials and to develop lubrication techniques. The results indicate that these seal materials must be lubricated to prevent wear and reduce friction. Thin films of silver, gold and calcium fluoride provided lubrication to the sliding materials.

  1. Prediction of the lifetime of nitrile-butadiene rubber by FT-IR.

    PubMed

    Kawashima, Tetsuya; Ogawa, Toshio

    2005-12-01

    A quantitative measurement method with FT-IR was proposed for a thermal degradation analysis of nitrile-butadiene rubber (NBR). An NBR film was prepared as a model sample on a barium fluoride (BaF2) crystal plate, which was subjected to a heat treatment. The absorbances of various functional groups were measured directly by FT-IR after thermal degradation at high temperatures. By measuring the absorbances, it was possible to readily determine quantitatively each of the functional groups after the degradation of NBR. By assuming that the NBR lifetime was the point at which the absorbance of a carbon-carbon double bond reaches 45% of that prior to thermal treatment, a method for predicting the lifetime of NBR heated below 150 degrees C was proposed, by using an Arrhenius plot of the heating time versus heating temperature.

  2. Coated conductors

    DOEpatents

    Arendt, Paul N.; Foltyn, Stephen R.; Stan, Liliana; Usov, Igor O.; Wang, Haiyan

    2010-06-15

    Articles are provided including a base substrate having a layer of an IBAD oriented material thereon, and, a layer of barium-containing material selected from the group consisting of barium zirconate, barium hafnate, barium titanate, barium strontium titanate, barium dysprosium zirconate, barium neodymium zirconate and barium samarium zirconate, or a cubic metal oxide material selected from the group consisting of rare earth zirconates and rare earth hafnates upon the layer of an IBAD oriented material. Such articles can further include thin films of high temperature superconductive oxides such as YBCO upon the layer of barium-containing material selected from the group consisting of barium zirconate, barium hafnate, barium titanate, barium strontium titanate, barium dysprosium zirconate, barium neodymium zirconate and barium samarium zirconate, or a cubic metal oxide material selected from the group consisting of rare earth zirconates and rare earth hafnates.

  3. Novel design of highly [110]-oriented barium titanate nanorod array and its application in nanocomposite capacitors.

    PubMed

    Yao, Lingmin; Pan, Zhongbin; Zhai, Jiwei; Chen, Haydn H D

    2017-03-23

    Nanocomposites in capacitors combining highly aligned one dimension ferroelectric nanowires with polymer would be more desirable for achieving higher energy density. However, the synthesis of the well-isolated ferroelectric oxide nanorod arrays with a high orientation has been rather scant, especially using glass-made substrates. In this study, a novel design that is capable of fabricating a highly [110]-oriented BaTiO 3 (BT) nanorod array was proposed first, using a three-step hydrothermal reaction on glass-made substrates. The details for controlling the dispersion of the nanorod array, the orientation and the aspect ratio are also discussed. It is found that the alkaline treatment of the TiO 2 (TO) nanorod array, rather than the completing transformation into sodium titanate, favors the transformation of the TO into the BT nanorod array, as well as protecting the glass-made substrate. The dispersity of the nanorod array can be controlled by the introduction of a glycol ether-deionized water mixed solvent and soluble salts. Moreover, the orientation of the nanorod arrays could be tuned by the ionic strength of the solution. This novel BT nanorod array was used as a filler in a nanocomposite capacitor, demonstrating that a large energy density (11.82 J cm -3 ) can be achieved even at a low applied electric field (3200 kV cm -1 ), which opens us a new application in nanocomposite capacitors.

  4. P(VDF-TrFE)/BaTiO3 Nanoparticle Composite Films Mediate Piezoelectric Stimulation and Promote Differentiation of SH-SY5Y Neuroblastoma Cells.

    PubMed

    Genchi, Giada Graziana; Ceseracciu, Luca; Marino, Attilio; Labardi, Massimiliano; Marras, Sergio; Pignatelli, Francesca; Bruschini, Luca; Mattoli, Virgilio; Ciofani, Gianni

    2016-07-01

    Poly(vinylidene fluoride-trifluoroethylene, P(VDF-TrFE)) and P(VDF-TrFE)/barium titanate nanoparticle (BTNP) films are prepared and tested as substrates for neuronal stimulation through direct piezoelectric effect. Films are characterized in terms of surface, mechanical, and piezoelectric features before in vitro testing on SH-SY5Y cells. In particular, BTNPs significantly improve piezoelectric properties of the films (4.5-fold increased d31 ). Both kinds of films support good SH-SY5Y viability and differentiation. Ultrasound (US) stimulation is proven to elicit Ca(2+) transients and to enhance differentiation in cells grown on the piezoelectric substrates. For the first time in the literature, this study demonstrates the suitability of polymer/ceramic composite films and US for neuronal stimulation through direct piezoelectric effect. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Analytical results and sample locality map of heavy-mineral-concentrate and rock samples from the Castle Peaks Wilderness Study Area (CDCA- 266), San Bernardino County, California

    USGS Publications Warehouse

    Adrian, B.M.; Frisken, J.G.; Malcolm, M.J.; Crock, J.G.

    1986-01-01

    The report presents water-quality and geohydrologic information for 106 public water-supply wells in Illinois. These wells were sampled during April to December 1984 as part of a pilot program to develop a ground-water observation network in the State. The pilot program was designed to sample single-aquifer wells from three major aquifer systems--(1) sand and gravel, both confined and unconfined; (2) Silurian dolomite; and (3) the Ironton-Galesville deep sandstone. Data are tabulated for water temperature, pH, specific conductance, oxidation-reduction potential, ammonia nitrogen, nitrate + nitrite nitrogen, phosphorus, silica, arsenic, lead, mercury, fluoride, chloride, sulfate, cyanide, phenols, selenium, residue on evaporation at 180 degrees Celsius, alkalinity, calcium, magnesium, sodium, potassium, barium, boron, beryllium, cadmium, chormium, copper, cobalt, iron, aluminum, manganese, nickel, silver, strontium, vanadium, zinc, and selected geohydrologic information.

  6. Radiology of colorectal cancer.

    PubMed

    Pijl, M E J; Chaoui, A S; Wahl, R L; van Oostayen, J A

    2002-05-01

    In the past 20 years, the radiology of colorectal cancer has evolved from the barium enema to advanced imaging modalities like phased array magnetic resonance imaging (MRI), virtual colonoscopy and positron emission tomography (PET). Nowadays, primary rectal cancers are preferably imaged with transrectal ultrasound or MRI, while barium enema is still the most often used technique for imaging of colonic cancers. Virtual colonoscopy is rapidly evolving and might considerably change the imaging of colorectal cancer in the near future. The use of virtual colonoscopy for screening purposes and imaging of the colon in occlusive cancer or incomplete colonoscopies is currently under evaluation. The main role of PET is in detecting tumour recurrences, both locally and distantly. Techniques to fuse cross-sectional anatomical (computer tomography (CT) and MRI) and functional (PET) images are being developed. Apart from diagnostic imaging, the radiologists has added image-guided minimally invasive treatments of colorectal liver metastases to their arsenal. The radio-frequency ablation technique is now widely available, and can be used during laparotomy or percutaneously in selected cases.

  7. Permanent magnetic ferrite based power-tunable metamaterials

    NASA Astrophysics Data System (ADS)

    Zhang, Guanqiao; Lan, Chuwen; Gao, Rui; Zhou, Ji

    2017-08-01

    Power-tunable metamaterials based on barium permanent magnetic ferrite have been proposed and fabricated in this research. Scattering parameter measurements confirm a shift in resonant frequency in correlation to changes in incident electromagnetic power within microwave frequency band. The tunable phenomenon represented by a blue-shift in transmission spectra in the metamaterials array can be attributed to a decrease in saturation magnetization resulting from FMR-induced temperature elevation upon resonant conditions. This power-dependent behavior offers a simple and practical route towards dynamically fine-tunable ferrite metamaterials.

  8. Thin-film sparse boundary array design for passive acoustic mapping during ultrasound therapy.

    PubMed

    Coviello, Christian M; Kozick, Richard J; Hurrell, Andrew; Smith, Penny Probert; Coussios, Constantin-C

    2012-10-01

    A new 2-D hydrophone array for ultrasound therapy monitoring is presented, along with a novel algorithm for passive acoustic mapping using a sparse weighted aperture. The array is constructed using existing polyvinylidene fluoride (PVDF) ultrasound sensor technology, and is utilized for its broadband characteristics and its high receive sensitivity. For most 2-D arrays, high-resolution imagery is desired, which requires a large aperture at the cost of a large number of elements. The proposed array's geometry is sparse, with elements only on the boundary of the rectangular aperture. The missing information from the interior is filled in using linear imaging techniques. After receiving acoustic emissions during ultrasound therapy, this algorithm applies an apodization to the sparse aperture to limit side lobes and then reconstructs acoustic activity with high spatiotemporal resolution. Experiments show verification of the theoretical point spread function, and cavitation maps in agar phantoms correspond closely to predicted areas, showing the validity of the array and methodology.

  9. Anomalous dielectrophoretic behaviour of barium titanate microparticles in concentrated solutions of ampholytes

    NASA Astrophysics Data System (ADS)

    Flores-Rodriguez, N.; Markx, G. H.

    2006-08-01

    The dielectrophoretic behaviour of barium titanate (BaTiO3) particles with a mean grain size of 3 µm was studied. Suspensions of the powdered ceramic in the concentration range 0.01-1.60% (w/v) were prepared in dilute aqueous solutions of NaCl and concentrated aqueous solutions of the amphoteric molecules HEPES (N-[2-hydroxyethyl] piperazine-N'4-[2-ethanesulfonic acid] and EACA (ɛ -aminocaproic acid). When suspended in water without ampholytes, the particles showed positive dielectrophoresis (DEP) over the whole frequency range (1 kHz-20 MHz), independent of the medium conductivity or applied voltage. When amphoteric molecules were added at a final concentration of up to 0.57 M, the particles showed positive DEP at all frequencies. When the concentration of ampholytes was increased to 0.71 M, the particles showed positive DEP at frequencies up to 100 kHz and voltages lower than 12 Vpk-pk at all electrode sizes. However, at 100 kHz, when the amplitude was increased to over 12 Vpk-pk, the particles started to display negative DEP at the smallest electrode size (20 µm) and moved away from the microelectrodes, accumulating in the gap between the electrodes. At the highest voltages used (16-20 Vpk-pk), the particles were seen moving upwards and remained stably levitated above the array. For frequencies larger than 100 kHz, the particles showed positive DEP only. It is shown that such behaviour cannot be expected on the basis of the dielectric properties of barium titanate and the suspending medium, and it is suggested that this behaviour may be caused by the fact that at high amphotere concentration and voltages the electric field across the particles surpasses the dielectric strength of the BaTiO3 particles, resulting in a sudden drop in the particle's permittivity. The fact that not all particles showed negative DEP suggests a spread in the dielectric properties of barium titanate particles. Physical separation of barium titanate particles with presumably different dielectric properties was shown to be possible using a flow-through device.

  10. Sulphate removal from sodium sulphate-rich brine and recovery of barium as a barium salt mixture.

    PubMed

    Vadapalli, Viswanath R K; Zvimba, John N; Mulopo, Jean; Motaung, Solly

    2013-01-01

    Sulphate removal from sodium sulphate-rich brine using barium hydroxide and recovery of the barium salts has been investigated. The sodium sulphate-rich brine treated with different dosages of barium hydroxide to precipitate barium sulphate showed sulphate removal from 13.5 g/L to less than 400 mg/L over 60 min using a barium to sulphate molar ratio of 1.1. The thermal conversion of precipitated barium sulphate to barium sulphide achieved a conversion yield of 85% using coal as both a reducing agent and an energy source. The recovery of a pure mixture of barium salts from barium sulphide, which involved dissolution of barium sulphide and reaction with ammonium hydroxide resulted in recovery of a mixture of barium carbonate (62%) and barium hydroxide (38%), which is a critical input raw material for barium salts based acid mine drainage (AMD) desalination technologies. Under alkaline conditions of this barium salt mixture recovery process, ammonia gas is given off, while hydrogen sulfide is retained in solution as bisulfide species, and this provides basis for ammonium hydroxide separation and recovery for reuse, with hydrogen sulfide also recoverable for further industrial applications such as sulfur production by subsequent stripping.

  11. Evaluation of adhesive-free crossed-electrode poly(vinylidene fluoride) copolymer array transducers for high frequency imaging

    NASA Astrophysics Data System (ADS)

    Wagle, Sanat; Decharat, Adit; Habib, Anowarul; Ahluwalia, Balpreet S.; Melandsø, Frank

    2016-07-01

    High frequency crossed-electrode transducers have been investigated, both as single and dual layer transducers. Prototypes of these transducers were developed for 4 crossed lines (yielding 16 square elements) on a polymer substrate, using a layer-by-layer deposition method for poly(vinylidene fluoride-trifluoroethylene) [P(VDF-TrFE)] with intermediate sputtered electrodes. The transducer was characterized using various methods [LCR analyzer, a pulse-echo experimental setup, and a numerical Finite element method (FEM) model] and evaluated in terms of uniformity of bandwidth and acoustical energy output. All 16 transducer elements produced broad-banded ultrasonic spectra with small variation in central frequency and -6 dB bandwidth. The frequency responses obtained experimentally were verified using a numerical model.

  12. Modeling and minimization of barium sulfate scale

    Treesearch

    Alan W. Rudie; Peter W. Hart

    2006-01-01

    The majority of the barium present in the pulping process exits the digester as barium carbonate. Barium carbonate dissolves in the bleach plant when the pH drops below 7 and, if barium and sulfate concentrations are too high, begins to precipitate as barium sulfate. Barium is difficult to control because a mill cannot avoid this carbonate-to-sulfate transition using...

  13. P(VDF-TrFE) ferroelectric nanotube array for high energy density capacitor applications.

    PubMed

    Li, Xue; Lim, Yee-Fun; Yao, Kui; Tay, Francis Eng Hock; Seah, Kar Heng

    2013-01-14

    Poly(vinylidene-fluoride-co-trifluoroethylene) (P(VDF-TrFE)) ferroelectric nanotube arrays were fabricated using an anodized alumina membrane (AAM) as a template and silver electrodes were deposited on both the outer and inner sides of the nanotubes by an electroless plating method. The nanotubes have the unique structure of being sealed at one end and linked at the open end, thus preventing electrical shorting between the inner and outer electrodes. Compared with a P(VDF-TrFE) film with a similar overall thickness, the idealized nanotube array has a theoretical capacitance that is 763 times larger due to the greatly enlarged contact area between the electrodes and the polymer dielectric. A capacitance that is 95 times larger has been demonstrated experimentally, thus indicating that such nanotube arrays are promising for realizing high density capacitance and high power dielectric energy storage.

  14. Mechanisms for the Crystallization of Zblan

    NASA Technical Reports Server (NTRS)

    Ethridge, Edwin C.; Tucker, Dennis S.

    2001-01-01

    The heavy metal fluoride glasses represent a class of reasonably good glass forming compositions with very unique infrared optical properties that have been of interest to researchers for 20 years. The most extensively studied glass with the most potential for practical applications is ZBLAN which contains the fluorides of zirconium, barium, lanthanum, aluminum, and sodium. It has a broad transmission range (0.3-6 um), low index of refraction (about 1.43), low dispersion, low Raleigh scattering, ultra-low thermal 2 dispersion, and potential ultra-low signal attenuation. Potential applications include fiber amplifiers, fiber optic gyroscopes, delivery systems for laser cutting, drilling and surgery, radiation resistant data links, nonlinear optical systems, and ultra-low-loss repeater-less transcontinental and transoceanic optical fiber. Potential markets for these materials are in the tens of billions of dollars per year. Optical fiber from this system possess excellent transmission characteristics in the IR, but the glass is somewhat susceptible to nucleation and crystallization. The theoretical intrinsic loss coefficient for ZBLAN at 2 microns is 0.00 1 dB/Km. Extrinsic losses, however, cause significant attenuation. The lowest loss coefficient measured is 0.7 dB/Km. This compares with the loss coefficient for fiber optic grade fused silica glass of 0.2 dB/Km. The extrinsic losses in ZBLAN have been attributed to 1) impurities which might be lowered by containerless processing and 2) to scattering from micro-crystallites that form during glass preform production or during fiber drawing.

  15. Effects of atmosphere on the tribological properties of a chromium carbide based coating for use to 760 deg C

    NASA Technical Reports Server (NTRS)

    Dellacorte, Chris; Sliney, Harold E.

    1986-01-01

    The effect of atmosphere on the tribological properties of a plasma-sprayed chromium carbide based self-lubricating coating is reported. The coating contains bonded chromium carbide as the wear resistant base stock to which the lubricants silver and barium fluoride/calcium fluoride eutectic are added. It has been denoted as NASA PS200. Potential applications for the PS200 coating are cylinder wall/piston ring couples for Stirling engines and foil bearing journal lubrication. Friction and wear studies were performed in helium, hydrogen, and moist air at temperatures from 25 to 760 C. In general, the atmosphere had a significant effect on both the friction and the wear of the coating and counterface material. Specimens tested in hydrogen, a reducing environment, exhibited the best tribological properties. Friction and wear increased in helium and air but are still within acceptable limits for intended applications. A variety of X-ray analyses was performed on the test specimens in an effort to explain the results. The following conclusions are made: (1) As the test atmosphere becomes less reducing, the coating experiences a higher concentration level of chromic oxide at the sliding interface which increases both the friction and wear. (2) Beneficial silver transfer from the parent coating to the counter-face material is less effective in air than in helium or hydrogen. (3) There may be a direct relationship between chromic oxide level present at the sliding interface and the friction coefficient.

  16. The effects of atmosphere on the tribological properties of a chromium carbide based coating for use to 760 C

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher; Sliney, Harold E.

    1988-01-01

    The effect of atmosphere on the tribological properties of a plasma-sprayed chromium carbide based self-lubricating coating is reported. The coating contains bonded chromium carbide as the wear resistant base stock to which the lubricants silver and barium fluoride/calcium fluoride eutectic are added. It has been denoted as NASA PS200. Potential applications for the PS200 coating are cylinder wall/piston ring couples Stirling engines and foil bearing journal lubrication. Friction and wear studies were performed in helium, hydrogen, and moist air at temperatures from 25 to 760 C. In general, the atmosphere had a significant effect on both the friction and the wear of the coating and counterface material. Specimens tested in hydrogen, a reducing environment, exhibited the best tribological properties. Friction and wear increased in helium and air but are still within acceptable limits for intended applications. A variety of X-ray analyses was performed on the test specimens in an effort to explain the results. The following conclusions are made: (1) As the test atmosphere becomes less reducing, the coating experiences a higher concentration level of chromic oxide at the sliding interface which increases both the friction and wear. (2) Beneficial silver transfer from the parent coating to the counter-face material is less effective in air than in helium or hydrogen. (3) There may be a direct relationship between chromic oxide level present at the sliding interface and the friction coefficient.

  17. Strain-tolerant ceramic coated seal

    DOEpatents

    Schienle, James L.; Strangman, Thomas E.

    1994-01-01

    A metallic regenerator seal is provided having multi-layer coating comprising a NiCrAlY bond layer, a yttria stabilized zirconia (YSZ) intermediate layer, and a ceramic high temperature solid lubricant surface layer comprising zinc oxide, calcium fluoride, and tin oxide. An array of discontinuous grooves is laser machined into the outer surface of the solid lubricant surface layer making the coating strain tolerant.

  18. Tunable ferroelectric meta-material phase shifter embedded inside low temperature co-fired ceramics (LTCC)

    NASA Astrophysics Data System (ADS)

    Tork, Hossam S.

    This dissertation describes electrically tunable microwave devices utilizing low temperature co-fired ceramics (LTCC) and thick film via filled with the ferroelectric materials barium strontium titanate (BST) and barium zirconate titanate (BZT). Tunable ferroelectric capacitors, zero meta-material phase shifters, and tunable meta-material phase shifters are presented. Microwave phase shifters have many applications in microwave devices. They are essential components for active and passive phased array antennas and their most common use is in scanning phased array antennas. They are used in synthetic aperture radars (SAR), low earth orbit (LEO) communication satellites, collision warning radars, and intelligent vehicle highway systems (IVHS), in addition to various other applications. Tunable ferroelectric materials have been investigated, since they offer the possibility of lowering the total cost of phased arrays. Two of the most promising ferroelectric materials in microwave applications are BST and BZT. The proposed design and implementation in this research introduce new types of tunable meta-material phase shifters embedded inside LTCC, which use BST and BZT as capacitive tunable dielectric material controlled by changing the applied voltage. This phase shifter has the advantages of meta-material structures, which produce little phase error and compensation while having the simultaneous advantage of using LTCC technology for embedding passive components that improve signal integrity (several signal lines, power planes, and ground planes) by using different processes like via filling, screen printing, laminating and firing that can be produced in compact sizes at a low cost. The via filling technique was used to build tunable BST, BZT ferroelectric material capacitors to control phase shift. Finally, The use of the proposed ferroelectric meta-material phase shifter improves phase shifter performance by reducing insertion loss in both transmitting and receiving directions for phased array antennas, reducing phase error, improving figure of merit (FOM) and phase shifter tunability around center frequency, and also enables the integration of the phase shifters with the microwave circuits on one substrate, thus substantially reducing the size, mass, and cost of the antennas.

  19. Barium light source method and apparatus

    NASA Technical Reports Server (NTRS)

    Curry, John J. (Inventor); MacDonagh-Dumler, Jeffrey (Inventor); Anderson, Heidi M. (Inventor); Lawler, James E. (Inventor)

    2002-01-01

    Visible light emission is obtained from a plasma containing elemental barium including neutral barium atoms and barium ion species. Neutral barium provides a strong green light emission in the center of the visible spectrum with a highly efficient conversion of electrical energy into visible light. By the selective excitation of barium ionic species, emission of visible light at longer and shorter wavelengths can be obtained simultaneously with the green emission from neutral barium, effectively providing light that is visually perceived as white. A discharge vessel contains the elemental barium and a buffer gas fill therein, and a discharge inducer is utilized to induce a desired discharge temperature and barium vapor pressure therein to produce from the barium vapor a visible light emission. The discharge can be induced utilizing a glow discharge between electrodes in the discharge vessel as well as by inductively or capacitively coupling RF energy into the plasma within the discharge vessel.

  20. BARIUM RECOVERY PROCESS

    DOEpatents

    Blanco, R.E.

    1959-07-21

    A method of separating barium from nuclear fission products is described. In accordance with the invention, barium may be recovered from an acidic solution of neutron-irradiated fissionable material by carrying ihe barium cut of solution as a sulfate with lead as a carrier and then dissolving the barium-containing precipitate in an aqueous solution of an aliphatic diamine chelating reagent. The barium values together with certain other metallic values present in the diamine solution are then absorbed onto a cation exchange resin and the barium is selectively eluted from the resin bed with concentrated nitric acid.

  1. Improved flexoelectricity in PVDF/barium strontium titanate (BST) nanocomposites

    NASA Astrophysics Data System (ADS)

    Hu, Xinping; Zhou, Yang; Liu, Jie; Chu, Baojin

    2018-04-01

    The flexoelectric effect of polymers is normally much weaker than that of ferroelectric oxides. In order to improve the flexoelectric response of the poly(vinylidene fluoride) (PVDF) ferroelectric polymer, PVDF/Ba0.67Si0.33TiO3 (BST) nanocomposites were fabricated. BST nanofibers were prepared by the electrospinning method, and the fibers were further surface modified with H2O2 to achieve a stronger interfacial interaction between the fibers and polymer matrix. Due to the high dielectric properties and strong flexoelectric effect of the BST, both dielectric constant and flexoelectric response of the composite with 25 vol. % surface modified BST are 3-4 times higher than those of PVDF. The dependence of the dielectric constant and the flexoelectric coefficient on the composition of the nanocomposites can be fitted by the empirical Yamada model, and the dielectric constant and the flexoelectric coefficient are correlated by a linear relationship. This study provides an approach to enhance the flexoelectric response of PVDF-based polymers.

  2. Giant thermo-optical relaxation oscillations in millimeter-size whispering gallery mode disk resonators.

    PubMed

    Diallo, Souleymane; Lin, Guoping; Chembo, Yanne K

    2015-08-15

    In this Letter, we show that giant thermo-optical oscillations can be triggered in millimeter (mm)-size whispering gallery mode (WGM) disk resonators when they are pumped by a resonant continuous-wave laser. Our resonator is an ultrahigh-Q barium fluoride cavity that features a positive thermo-optic coefficient and a negative thermo-elastic coefficient. We demonstrate for the first time, to our knowledge, that the complex interplay between these two thermic coefficients and the intrinsic Kerr nonlinearity yields very sharp slow-fast relaxation oscillations with a slow timescale that can be exceptionally large, typically of the order of 1 s. We use a time-domain model to gain understanding into this instability, and we find that both the experimental and theoretical results are in excellent agreement. The understanding of these thermal effects is an essential requirement for every WGM-related application and our study demonstrates that even in the case of mm-size resonators, such effects can still be accurately analyzed using nonlinear time-domain models.

  3. Relationship between BaTiO₃ nanowire aspect ratio and the dielectric permittivity of nanocomposites.

    PubMed

    Tang, Haixiong; Zhou, Zhi; Sodano, Henry A

    2014-04-23

    The aspect ratio of barium titanate (BaTiO3) nanowires is demonstrated to be successfully controlled by adjusting the temperature of the hydrothermal growth from 150 to 240 °C, corresponding to aspect ratios from 9.3 to 45.8, respectively. Polyvinylidene fluoride (PVDF) nanocomposites are formed from the various aspect ratio nanowires and the relationship between the dielectric constant of the nanocomposite and the aspect ratio of the fillers is quantified. It was found that the dielectric constant of the nanocomposite increases with the aspect ratio of the nanowires. Nanocomposites with 30 vol % BaTiO3 nanowires and an aspect ratio of 45.8 can reach a dielectric constant of 44.3, which is 30.7% higher than samples with an aspect ratio of 9.3 and 352% larger than the polymer matrix. These results demonstrate that using high-aspect-ratio nanowires is an effective way to control and improve the dielectric performance of nanocomposites for future capacitor applications.

  4. Spectroscopic properties of heavily Ho3+-doped barium yttrium fluoride crystals

    NASA Astrophysics Data System (ADS)

    Ji, En-Cai; Liu, Qiang; Nie, Ming-Ming; Luo, Hui; Hu, Yu-Xi; Guan, Zhou-Guo; Gong, Ma-Li

    2015-09-01

    The 30 at.% Ho: BaY2F8 crystals were grown by the Czochralski method, and their spectroscopic properties are analyzed systematically by standard Judd-Ofelt theory. The Judd-Ofelt intensity parameters are estimated to be Ω2 = 6.74 × 10-20 cm2, Ω4 = 1.20 × 10-20 cm2, and Ω6 = 0.66 × 10-20 cm2, and the fluorescence branching ratios and radiative lifetimes for a series of excited state manifolds are also determined. The emission cross sections with our measured infrared luminescence spectra, especially important for 4.1 μm, are calculated to be about 4.37 × 10-21 cm2. The crystal quality is preliminarily tested through a mid-infrared laser emission experiment. Project supported by the National Natural Science Foundation of China (Grant No. 61275146), the Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20120002110066), and the Special Program of the Co-construction with Beijing Municipal Government of China (Grant No. 20121000302).

  5. Monte Carlo simulation studies on scintillation detectors and image reconstruction of brain-phantom tumors in TOFPET

    PubMed Central

    Mondal, Nagendra Nath

    2009-01-01

    This study presents Monte Carlo Simulation (MCS) results of detection efficiencies, spatial resolutions and resolving powers of a time-of-flight (TOF) PET detector systems. Cerium activated Lutetium Oxyorthosilicate (Lu2SiO5: Ce in short LSO), Barium Fluoride (BaF2) and BriLanCe 380 (Cerium doped Lanthanum tri-Bromide, in short LaBr3) scintillation crystals are studied in view of their good time and energy resolutions and shorter decay times. The results of MCS based on GEANT show that spatial resolution, detection efficiency and resolving power of LSO are better than those of BaF2 and LaBr3, although it possesses inferior time and energy resolutions. Instead of the conventional position reconstruction method, newly established image reconstruction (talked about in the previous work) method is applied to produce high-tech images. Validation is a momentous step to ensure that this imaging method fulfills all purposes of motivation discussed by reconstructing images of two tumors in a brain phantom. PMID:20098551

  6. Synthesis of YBa2CU3O7 using sub-atmospheric processing

    DOEpatents

    Wiesmann, Harold; Solovyov, Vyacheslav

    2004-09-21

    The present invention is a method of forming thick films of crystalline YBa.sub.2 Cu.sub.3 O.sub.7 that includes forming a precursor film comprising barium fluoride (BaF.sub.2), yttrium (Y) and copper (Cu). The precursor film is heat-treated at a temperature above 500.degree. C. in the presence of oxygen, nitrogen and water vapor at sub-atmospheric pressure to form a crystalline structure. The crystalline structure is then annealed at about 500.degree. C. in the presence of oxygen to form the crystalline YBa.sub.2 Cu.sub.3 O.sub.7 film. The YBa.sub.2 Cu.sub.3 O.sub.7 film formed by this method has a resistivity of from about 100 to about 600 .mu.Ohm-cm at room temperature and a critical current density measured at 77 K in a magnetic field of 1 Tesla of about 1.0.times.10.sup.5 Ampere per square centimeter (0.1 MA/cm.sup.2) or greater.

  7. VizieR Online Data Catalog: Infrared properties of barium stars (Chen+, 2001)

    NASA Astrophysics Data System (ADS)

    Chen, P. S.

    2001-04-01

    We present the results of a systematic survey for IRAS associations of barium stars. A total of 155 associations were detected, and IRAS low-resolution spectra exist for 50 barium stars. We use different color-color diagrams from the visual band to 60μm, relations between these colors and the spectral type, the barium intensity, and the IRAS low-resolution spectra to discuss physical properties of barium stars in the infrared. It is confirmed that most barium stars have infrared excesses in the near infrared. However, a new result of this work is that most barium stars have no excesses in the far infrared. This fact may imply that infrared excesses of barium stars are mainly due to the re-emission of energy lost from the Bond-Neff depression. It is also shown that the spectral type and the barium intensity of barium stars are not correlated with infrared colors, but may be correlated with V-K color. (1 data file).

  8. Radioactive Barium Ion Trap Based on Metal-Organic Framework for Efficient and Irreversible Removal of Barium from Nuclear Wastewater.

    PubMed

    Peng, Yaguang; Huang, Hongliang; Liu, Dahuan; Zhong, Chongli

    2016-04-06

    Highly efficient and irreversible capture of radioactive barium from aqueous media remains a serious task for nuclear waste disposal and environmental protection. To address this task, here we propose a concept of barium ion trap based on metal-organic framework (MOF) with a strong barium-chelating group (sulfate and sulfonic acid group) in the pore structures of MOFs. The functionalized MOF-based ion traps can remove >90% of the barium within the first 5 min, and the removal efficiency reaches 99% after equilibrium. Remarkably, the sulfate-group-functionalized ion trap demonstrates a high barium uptake capacity of 131.1 mg g(-1), which surpasses most of the reported sorbents and can selectively capture barium from nuclear wastewater, whereas the sulfonic-acid-group-functionalized ion trap exhibits ultrafast kinetics with a kinetic rate constant k2 of 27.77 g mg(-1) min(-1), which is 1-3 orders of magnitude higher than existing sorbents. Both of the two MOF-based ion traps can capture barium irreversibly. Our work proposes a new strategy to design barium adsorbent materials and provides a new perspective for removing radioactive barium and other radionuclides from nuclear wastewater for environment remediation. Besides, the concrete mechanisms of barium-sorbent interactions are also demonstrated in this contribution.

  9. Selection of plants for phytoremediation of barium-polluted flooded soils.

    PubMed

    Ribeiro, Paulo Roberto Cleyton de Castro; Viana, Douglas Gomes; Pires, Fábio Ribeiro; Egreja Filho, Fernando Barboza; Bonomo, Robson; Cargnelutti Filho, Alberto; Martins, Luiz Fernando; Cruz, Leila Beatriz Silva; Nascimento, Mauro César Pinto

    2018-05-10

    The use of barite (BaSO4) in drilling fluids for oil and gas activities makes barium a potential contaminant in case of spills onto flooded soils, where low redox conditions may increase barium sulfate solubility. In order to select plants able to remove barium in such scenarios, the following species were evaluated on barium phytoextraction capacity: Brachiaria arrecta, Cyperus papyrus, Eleocharis acutangula, E. interstincta, Nephrolepsis cf. rivularis, Oryza sativa IRGA 424, O. sativa BRS Tropical, Paspalum conspersum, and Typha domingensis. Plants were grown in pots and exposed to six barium concentrations: 0, 2.5, 5.0, 10.0, 30.0, and 65.0 mg kg -1 . To simulate flooding conditions, each pot was kept with a thin water film over the soil surface (∼1.0 cm). Plants were evaluated for biomass yield and barium removal. The highest amount of barium was observed in T. domingensis biomass, followed by C. papyrus. However, the latter exported most of the barium to the aerial part of the plant, especially at higher BaCl 2 doses, while the former accumulated barium preferentially in the roots. Thus, barium removal with C. papyrus could be achieved by simply harvesting aerial biomass. The high amounts of barium in T. domingensis and C. papyrus resulted from the combination of high barium concentration in plant tissues with high biomass production. These results make T. domingensis and C. papyrus potential candidates for phytoremediation schemes to remove barium from flooded soils. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. FRZB1 rs2242070 polymorphisms is associated with brick tea type skeletal fluorosis in Kazakhs, but not in Tibetans, China.

    PubMed

    Yang, Yanmei; Zhao, Qiaoshi; Liu, Yang; Liu, Xiaona; Chu, Yanru; Yan, Huazhu; Fan, Yumei; Huo, Simeng; Wang, Limei; Lou, Qun; Guo, Ning; Sun, Dianjun; Gao, Yanhui

    2018-05-21

    Skeletal fluorosis is a metabolic bone and joint disease caused by excessive accumulation of fluoride in the bones. Compared with Kazakhs, Tibetans are more likely to develop moderate and severe brick tea type skeletal fluorosis, although they have similar fluoride exposure. Single nucleotide polymorphisms (SNPs) in frizzled-related protein (FRZB) have been associated with osteoarthritis, but their association with the risk of skeletal fluorosis has not been reported. In this paper, we investigated the association of three SNPs (rs7775, rs2242070 and rs9288087) in FRZB1with brick tea type skeletal fluorosis risk in a cross-sectional case-control study conducted in Sinkiang and Qinghai, China. A total of 598 individuals, including 308 Tibetans and 290 Kazakhs, were enrolled in this study, in which cases and controls were 221 and 377, respectively. The skeletal fluorosis was diagnosed according to the Chinese diagnostic criteria of endemic skeletal fluorosis (WS192-2008). The fluoride content in tea water or urine was detected using the fluoride ion electrode. SNPs were assessed using the Sequenom MassARRAY system. Binary logistic regressions found evidence of association with rs2242070 AA genotype in only Kazakh participants [odds ratio (OR) 0.417, 95% CI 0.216-0.807, p = 0.009], but not in Tibetans. When stratified by age, this protective effect of AA genotype in rs2242070 was pronounced in Kazakh participants aged 46-65 (OR 0.321, 95% CI 0.135-0.764, p = 0.010). This protective association with AA genotype in rs2242070 in Kazakhs also appeared to be stronger with tea fluoride intake > 3.5 mg/day (OR 0.396, 95% CI 0.182-0.864, p = 0.020). Our data suggest there might be differential genetic influence on skeletal fluorosis risk in Kazakh and Tibetan participants and that this difference might be modified by tea fluoride intake.

  11. Barium Depletion in the NSTAR Discharge Cathode After 30,000 Hours of Operation

    NASA Technical Reports Server (NTRS)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2010-01-01

    Dispenser hollow cathodes rely on a consumable supply of barium released by impregnant materials in the pores of a tungsten matrix to maintain a low work function surface. Examinations of cathode inserts from long duration ion engine tests show deposits of tungsten at the downstream end that appear to block the flow of barium from the interior. In addition, a numerical model of barium transport in the insert plasma indicates that the barium partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant barium-producing reaction, and it was postulated previously that this would suppress barium loss in the upstream part of the insert. New measurements of the depth of barium depletion from a cathode insert operated for 30,352 hours reveal that barium loss is confined to a narrow region near the downstream end, confirming this hypothesis.

  12. High energy density in PVDF nanocomposites using an optimized nanowire array.

    PubMed

    Guo, Ru; Luo, Hang; Liu, Weiwei; Zhou, Xuefan; Tang, Lin; Zhou, Kechao; Zhang, Dou

    2018-06-22

    TiO2 nanowire arrays are often utilized to prepare high performance polymer nanocomposites, however, the contribution to the energy density is limited due to their non-ferroelectric characteristics. A nanocomposite with an optimized nanowire array combining the ferroelectric properties of lead zirconate titanate (PZT) with TiO2, readily forming nanowires (denoted as a TiO2-P nanowire array), is prepared to enhance the permittivity. Poly(vinylidene fluoride) (PVDF) is used as the polymer matrix due to its high breakdown strength, e.g. 600-700 kV mm-1. As a result, the permittivity and breakdown electric field reach 53 at 1 kHz and 550 kV mm-1, respectively. Therefore, the nanocomposites achieve a higher discharge energy density of 12.4 J cm-3 with excellent cycle stability, which is the highest among nanocomposites based on a nanowire array as a filler in a PVDF matrix. This work provides not only a feasible approach to obtain high performance dielectric nanocomposites, but also a wide range of potential applications in the energy storage and energy harvesting fields.

  13. Methods of producing cesium-131

    DOEpatents

    Meikrantz, David H; Snyder, John R

    2012-09-18

    Methods of producing cesium-131. The method comprises dissolving at least one non-irradiated barium source in water or a nitric acid solution to produce a barium target solution. The barium target solution is irradiated with neutron radiation to produce cesium-131, which is removed from the barium target solution. The cesium-131 is complexed with a calixarene compound to separate the cesium-131 from the barium target solution. A liquid:liquid extraction device or extraction column is used to separate the cesium-131 from the barium target solution.

  14. On the dispersion management of fluorite whispering-gallery mode resonators for Kerr optical frequency comb generation in the telecom and mid-infrared range.

    PubMed

    Lin, Guoping; Chembo, Yanne K

    2015-01-26

    Optical whispering gallery mode (WGM) resonators have been very attracting platforms for versatile Kerr frequency comb generations. We report a systematic study on the material dispersion of various optical materials that are capable of supporting quality factors above 109. Using an analytical approximation of WGM resonant frequencies in disk resonators, we investigate the effect of the geometry and transverse mode order on the total group-velocity dispersion (GVD). We demonstrate that the major radii and the radial mode indices play an important role in tailoring the GVD of WGM resonators. In particular, our study shows that in WGM disk-resonators, the polar families of modes have very similar GVD, while the radial families of modes feature dispersion values that can differ by up to several orders of magnitude. The effect of these giant dispersion shifts are experimentally evidenced in Kerr comb generation with magnesium fluoride. From a more general perspective, this critical feature enables to push the zero-dispersion wavelength of fluorite crystals towards the mid-infrared (mid-IR) range, thereby allowing for efficient Kerr comb generation in that spectral range. We show that barium fluoride is the most interesting crystal in this regard, due to its zero dispersion wavelength (ZDW) at 1.93 μm and an optimal dispersion profile in the mid-IR regime. We expect our results to facilitate the design of different platforms for Kerr frequency comb generations in both telecommunication and mid-IR spectral ranges.

  15. Nefopam Hydrochloride: A Fatal Overdose.

    PubMed

    Seetohul, L Nitin; De Paoli, Giorgia; Drummond, Gail; Maskell, Peter D

    2015-01-01

    Nefopam is a non-opiate analgesic commonly used for the treatment of moderate to severe pain. A case of a 37-year-old male who was found dead in the morning is presented. An autopsy was performed and femoral venous blood, heart blood, urine, and vitreous humor were submitted for toxicological analysis. A general drug screen detected the presence of nefopam, caffeine, nicotine, citalopram, gabapentin, amitriptyline, diazepam and paracetamol in cardiac blood. Nefopam was quantitated by high-performance liquid chromatography with diode-array detection. Nefopam was found at the following concentrations: 13.6 mg/L in unpreserved femoral blood; 14.7 mg/L in preserved (fluoride-oxalate) femoral blood; 21.2 mg/L in unpreserved cardiac blood and 4.5 mg/L in preserved vitreous. Citalopram was present at a concentration of 0.7 mg/L (femoral blood) and 0.9 mg/L (cardiac blood). Ethanol analyzed by headspace gas chromatography (GC-FID) was detected in preserved (fluoride-oxalate) vitreous (14 mg/100 mL) and preserved (fluoride-oxalate) urine 50 mg/100 mL. Death was attributed to atherosclerotic coronary artery disease and therapeutic drug toxicity. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Materials Refining for Solar Array Production on the Moon

    NASA Technical Reports Server (NTRS)

    Landis, Geoffrey A.

    2005-01-01

    Silicon, aluminum, and glass are the primary raw materials that will be required for production of solar arrays on the moon. A process sequence is proposed for producing these materials from lunar regolith, consisting of separating the required materials from lunar rock with fluorine. The fluorine is brought to the moon in the form of potassium fluoride, and is liberated from the salt by electrolysis in a eutectic salt melt. Tetrafluorosilane produced by this process is reduced to silicon by a plasma reduction stage; the fluorine salts are reduced to metals by reaction with metallic potassium. Fluorine is recovered from residual MgF and CaF2 by reaction with K2O.

  17. Effect of sulfur hexafluoride gas and post-annealing treatment for inductively coupled plasma etched barium titanate thin films

    PubMed Central

    2014-01-01

    Aerosol deposition- (AD) derived barium titanate (BTO) micropatterns are etched via SF6/O2/Ar plasmas using inductively coupled plasma (ICP) etching technology. The reaction mechanisms of the sulfur hexafluoride on BTO thin films and the effects of annealing treatment are verified through X-ray photoelectron spectroscopy (XPS) analysis, which confirms the accumulation of reaction products on the etched surface due to the low volatility of the reaction products, such as Ba and Ti fluorides, and these residues could be completely removed by the post-annealing treatment. The exact peak positions and chemicals shifts of Ba 3d, Ti 2p, O 1 s, and F 1 s are deduced by fitting the XPS narrow-scan spectra on as-deposited, etched, and post-annealed BTO surfaces. Compared to the as-deposited BTOs, the etched Ba 3d 5/2 , Ba 3d 3/2 , Ti 2p 3/2 , Ti 2p 1/2 , and O 1 s peaks shift towards higher binding energy regions by amounts of 0.55, 0.45, 0.4, 0.35, and 0.85 eV, respectively. A comparison of the as-deposited film with the post-annealed film after etching revealed that there are no significant differences in the fitted XPS narrow-scan spectra except for the slight chemical shift in the O 1 s peak due to the oxygen vacancy compensation in O2-excessive atmosphere. It is inferred that the electrical properties of the etched BTO film can be restored by post-annealing treatment after the etching process. Moreover, the relative permittivity and loss tangent of the post-annealed BTO thin films are remarkably improved by 232% and 2,695%, respectively. PMID:25249824

  18. Exposure to low-dose barium by drinking water causes hearing loss in mice.

    PubMed

    Ohgami, Nobutaka; Hori, Sohjiro; Ohgami, Kyoko; Tamura, Haruka; Tsuzuki, Toyonori; Ohnuma, Shoko; Kato, Masashi

    2012-10-01

    We continuously ingest barium as a general element by drinking water and foods in our daily life. Exposure to high-dose barium (>100mg/kg/day) has been shown to cause physiological impairments. Direct administration of barium to inner ears by vascular perfusion has been shown to cause physiological impairments in inner ears. However, the toxic influence of oral exposure to low-dose barium on hearing levels has not been clarified in vivo. We analyzed the toxic influence of oral exposure to low-dose barium on hearing levels and inner ears in mice. We orally administered barium at low doses of 0.14 and 1.4 mg/kg/day to wild-type ICR mice by drinking water. The doses are equivalent to and 10-fold higher than the limit level (0.7 mg/l) of WHO health-based guidelines for drinking water, respectively. After 2-week exposure, hearing levels were measured by auditory brain stem responses and inner ears were morphologically analyzed. After 2-month exposure, tissue distribution of barium was measured by inductively coupled plasma mass spectrometry. Low-dose barium in drinking water caused severe hearing loss in mice. Inner ears including inner and outer hair cells, stria vascularis and spiral ganglion neurons showed severe degeneration. The Barium-administered group showed significantly higher levels of barium in inner ears than those in the control group, while barium levels in bone did not show a significant difference between the two groups. Barium levels in other tissues including the cerebrum, cerebellum, heart, liver and kidney were undetectably low in both groups. Our results demonstrate for the first time that low-dose barium administered by drinking water specifically distributes to inner ears resulting in severe ototoxicity with degeneration of inner ears in mice. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Barium Depletion in Hollow Cathode Emitters

    NASA Technical Reports Server (NTRS)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2009-01-01

    The effect of tungsten erosion, transport and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from an 8200 hour and a 30,352 hour ion engine wear test. Erosion and subsequent re-deposition of tungsten in the electron emission zone at the downstream end of the insert reduces the porosity of the tungsten matrix, preventing the ow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushed back to the emitter surface by the electric field and drag from the xenon ion flow. This barium ion flux is sufficient to maintain a barium surface coverage at the downstream end greater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length, so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollow cathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  20. Controlling Morphological Parameters of Anodized Titania Nanotubes for Optimized Solar Energy Applications

    PubMed Central

    Haring, Andrew; Morris, Amanda; Hu, Michael

    2012-01-01

    Anodized TiO2 nanotubes have received much attention for their use in solar energy applications including water oxidation cells and hybrid solar cells [dye-sensitized solar cells (DSSCs) and bulk heterojuntion solar cells (BHJs)]. High surface area allows for increased dye-adsorption and photon absorption. Titania nanotubes grown by anodization of titanium in fluoride-containing electrolytes are aligned perpendicular to the substrate surface, reducing the electron diffusion path to the external circuit in solar cells. The nanotube morphology can be optimized for the various applications by adjusting the anodization parameters but the optimum crystallinity of the nanotube arrays remains to be realized. In addition to morphology and crystallinity, the method of device fabrication significantly affects photon and electron dynamics and its energy conversion efficiency. This paper provides the state-of-the-art knowledge to achieve experimental tailoring of morphological parameters including nanotube diameter, length, wall thickness, array surface smoothness, and annealing of nanotube arrays.

  1. P[N(i-Bu)CH(2)CH(2)](3)N: nonionic Lewis base for promoting the room-temperature synthesis of α,β-unsaturated esters, fluorides, ketones, and nitriles using Wadsworth-Emmons phosphonates.

    PubMed

    Chintareddy, Venkat Reddy; Ellern, Arkady; Verkade, John G

    2010-11-05

    The bicyclic triaminophosphine P(RNCH(2)CH(2))(3)N (R = i-Bu, 1c) serves as an effective promoter for the room-temperature stereoselective synthesis of α,β-unsaturated esters, fluorides, and nitriles from a wide array of aromatic, aliphatic, heterocyclic, and cyclic aldehydes and ketones, using a range of Wadsworth-Emmons (WE) phosphonates. Among the analogues of 1c [R = Me (1a), i-Pr (1b), Bn (1d)], 1a and 1b performed well, although longer reaction times were involved, and 1d led to poorer yields than 1c. Functionalities such as cyano, chloro, bromo, methoxy, amino, ester, and nitro were well tolerated. We were able to isolate and characterize (by X-ray means; see above) the reactive WE intermediate species formed from 2b and 1c.

  2. Status of barium studies in the present era of oncology: Are they a history?

    PubMed

    Mahajan, Abhishek; Desai, Subash; Sable, Nilesh Pandurang; Thakur, Meenakshi Haresh

    2016-01-01

    With the advent of the modern imaging technologies, the present era of oncology is seeing steady decline in requests for barium studies due to the many reasons. It is prudent to mention here, that, barium examinations cannot be made obsolete! Our aim to preserve the age old technique of barium studies not only to keep it going on but also for the betterment and appropriate management of the patient. Our goal is not to "save" barium studies simply to keep this technology alive, per se, but rather to preserve barium radiology for the quality in patient care.

  3. Effect of barium-coated halloysite nanotube addition on the cytocompatibility, mechanical and contrast properties of poly(methyl methacrylate) cement.

    PubMed

    Jammalamadaka, Uday; Tappa, Karthik; Weisman, Jeffery A; Nicholson, James Connor; Mills, David K

    2017-01-01

    Halloysite nanotubes (HNTs) were investigated as a platform for tunable nanoparticle composition and enhanced opacity in poly(methyl methacrylate) (PMMA) bone cement. Halloysite has been widely used to increase the mechanical properties of various polymer matrices, in stark contrast to other fillers such as barium sulfate that provide opacity but also decrease mechanical strength. The present work describes a dry deposition method for successively fabricating barium sulfate nanoparticles onto the exterior surface of HNTs. A sintering process was used to coat the HNTs in barium sulfate. Barium sulfate-coated HNTs were then added to PMMA bone cement and the samples were tested for mechanical strength and tailored opacity correlated with the fabrication ratio and the amount of barium sulfate-coated HNTs added. The potential cytotoxic effect of barium-coated HNTs in PMMA cement was also tested on osteosarcoma cells. Barium-coated HNTs were found to be completely cytocompatible, and cell proliferation was not inhibited after exposure to the barium-coated HNTs embedded in PMMA cement. We demonstrate a simple method for the creation of barium-coated nanoparticles that imparted improved contrast and material properties to native PMMA. An easy and efficient method for coating clay nanotubes offers the potential for enhanced imaging by radiologists or orthopedic surgeons.

  4. Barium toxicosis in a dog.

    PubMed

    Adam, Fiona H; Noble, Peter J M; Swift, Simon T; Higgins, Brent M; Sieniawska, Christine E

    2010-09-01

    A 2-year-old 14.9-kg (32.8-lb) neutered female Shetland Sheepdog was admitted to the University of Liverpool Small Animal Teaching Hospital for evaluation of acute collapse. At admission, the dog was tachypneic and had reduced limb reflexes and muscle tone in all limbs consistent with diffuse lower motor neuron dysfunction. The dog was severely hypokalemic (1.7 mEq/L; reference range, 3.5 to 5.8 mEq/L). Clinical status of the dog deteriorated; there was muscle twitching, flaccid paralysis, and respiratory failure, which was considered a result of respiratory muscle weakness. Ventricular arrhythmias and severe acidemia (pH, 7.18; reference range, 7.35 to 7.45) developed. Intoxication was suspected, and plasma and urine samples submitted for barium analysis had barium concentrations comparable with those reported in humans with barium toxicosis. Analysis of barium concentrations in 5 control dogs supported the diagnosis of barium toxicosis in the dog. Fluids and potassium supplementation were administered IV. The dog recovered rapidly. Electrolyte concentrations measured after recovery were consistently unremarkable. Quantification of plasma barium concentration 56 days after the presumed episode of intoxication revealed a large decrease; however, the plasma barium concentration remained elevated, compared with that in control dogs. To our knowledge, this case represented the first description of barium toxicosis in the veterinary literature. Barium toxicosis can cause life-threatening hypokalemia; however, prompt supportive treatment can yield excellent outcomes. Barium toxicosis is a rare but important differential diagnosis in animals with hypokalemia and appropriate clinical signs.

  5. Barium determination in gastric contents, blood and urine by inductively coupled plasma mass spectrometry in the case of oral barium chloride poisoning.

    PubMed

    Łukasik-Głębocka, Magdalena; Sommerfeld, Karina; Hanć, Anetta; Grzegorowski, Adam; Barałkiewicz, Danuta; Gaca, Michał; Zielińska-Psuja, Barbara

    2014-01-01

    A serious case of barium intoxication from suicidal ingestion is reported. Oral barium chloride poisoning with hypokalemia, neuromuscular and cardiac toxicity, treated with intravenous potassium supplementation and hemodialysis, was confirmed by the determination of barium concentrations in gastric contents, blood, serum and urine using the inductively coupled plasma mass spectrometry method. Barium concentrations in the analyzed specimens were 20.45 µg/L in serum, 150 µg/L in blood, 10,500 µg/L in urine and 63,500 µg/L in gastric contents. Results were compared with barium levels obtained from a non-intoxicated person. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Binding and Leakage of Barium in Alginate Microbeads

    PubMed Central

    Mørch, Yrr A.; Qi, Meirigeng; Gundersen, Per Ole M.; Formo, Kjetil; Lacik, Igor; Skjåk-Bræk, Gudmund; Oberholzer, Jose; Strand, Berit L.

    2013-01-01

    Microbeads of alginate cross-linked with Ca2+ and/or Ba2+ are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared to high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. In order to reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. PMID:22700168

  7. Binding and leakage of barium in alginate microbeads.

    PubMed

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  8. The diagnosis of gastro-esophageal reflux disease cannot be made with barium esophagograms.

    PubMed

    Saleh, C M G; Smout, A J P M; Bredenoord, A J

    2015-02-01

    For over 50 years, barium studies have been used to diagnose gastro-esophageal reflux disease (GERD), but the value of this test is controversial. Our study aimed to determine if barium esophagograms can be used to diagnose GERD. Barium esophagograms and pH-impedance measurement were performed in 20 subjects with reflux symptoms. pH-impedance measurements were used as gold standard for the diagnosis of GERD. Gastro-esophageal reflux measured with the barium study was defined as a positive outcome. 50% of patients presented gastro-esophageal reflux on the barium esophagogram. No significant differences were observed in acid exposure time between subjects with (median: 7.4%; interquartile range, IQR: 8.4%) or without reflux at barium esophagography (median: 5.95%; IQR: 13.05%; p > 0.05). Nor did we find differences in median proximal extent of reflux measured with impedance monitoring between patients with a positive (median: 6.7%; IQR: 1.95%) and negative barium study (median: 7.1%; IQR: 0.68%; p > 0.05). Patients with reflux on barium esophagogram did not have a positive symptom association probability more often than those who did not have reflux at barium esophagography. Lastly, there were no differences in numbers of acid, weakly acidic or total reflux episodes between those with positive or negative barium esophagogram (p > 0.05). No correlations were found between the maximum proximal extent of gastro-esophageal reflux during esophagography and pH-impedance parameters. Presence or absence of gastro-esophageal reflux during barium esophagography does not correlate with incidence or extent of reflux observed during 24-h pH-impedance monitoring and is not of value for the diagnosis of GERD. © 2014 John Wiley & Sons Ltd.

  9. A review of the health impacts of barium from natural and anthropogenic exposure.

    PubMed

    Kravchenko, Julia; Darrah, Thomas H; Miller, Richard K; Lyerly, H Kim; Vengosh, Avner

    2014-08-01

    There is an increasing public awareness of the relatively new and expanded industrial barium uses which are potential sources of human exposure (e.g., a shale gas development that causes an increased awareness of environmental exposures to barium). However, absorption of barium in exposed humans and a full spectrum of its health effects, especially among chronically exposed to moderate and low doses of barium populations, remain unclear. We suggest a systematic literature review (from 1875 to 2014) on environmental distribution of barium, its bioaccumulation, and potential and proven health impacts (in animal models and humans) to provide the information that can be used for optimization of future experimental and epidemiological studies and developing of mitigative and preventive strategies to minimize negative health effects in exposed populations. The potential health effects of barium exposure are largely based on animal studies, while epidemiological data for humans, specifically for chronic low-level exposures, are sparse. The reported health effects include cardiovascular and kidney diseases, metabolic, neurological, and mental disorders. Age, race, dietary patterns, behavioral risks (e.g., smoking), use of medications (those that interfere with absorbed barium in human organism), and specific physiological status (e.g., pregnancy) can modify barium effects on human health. Identifying, evaluating, and predicting the health effects of chronic low-level and moderate-level barium exposures in humans is challenging: Future research is needed to develop an understanding of barium bioaccumulation in order to mitigate its potential health impacts in various exposured populations. Further, while occupationally exposed at-risk populations exist, it is also important to identify potentially vulnerable subgroups among non-occupationally exposed populations (e.g., elderly, pregnant women, children) who are at higher risk of barium exposure from drinking water and food.

  10. Alteration of the fast excitatory postsynaptic current by barium in voltage-clamped amphibian sympathetic ganglion cells.

    PubMed Central

    Connor, E. A.; Parsons, R. L.

    1984-01-01

    Barium-induced alterations in fast excitatory postsynaptic currents (e.p.s.cs) have been studied in voltage-clamped bullfrog sympathetic ganglion B cells. In the presence of 2-8 mM barium, e.p.s.c. decay was prolonged and in many cells the e.p.s.c. decay phase deviated from a single exponential function. The decay phase in these cases was more accurately described as the sum of two exponential functions. The frequency of occurrence of a complex decay increased both with increasing barium concentration and with hyperpolarization. Miniature e.p.s.c. decay also was prolonged in barium-treated cells. E.p.s.c. amplitude was not markedly affected by barium (2-8 mM) in cells voltage-clamped to -50 mV whereas at -90 mV there was a progressive increase in peak size with increasing barium concentration. In control cells the e.p.s.c.-voltage relationship was linear between -20 and -100 mV; however, this relationship became progressively non-linear with membrane hyperpolarization in barium-treated cells. The e.p.s.c. reversal potential was shifted to a more negative value in the presence of barium. There was a voltage-dependent increase in charge movement during the e.p.s.c. in barium-treated cells which was not present in control cells. We conclude that the voltage-dependent alteration in e.p.s.c. decay time course, peak amplitude and charge movement in barium-treated cells is due to a direct postsynaptic action of barium on the kinetics of receptor-channel gating in postganglionic sympathetic neurones. PMID:6333261

  11. Hertzsprung-Russell diagram and mass distribution of barium stars

    NASA Astrophysics Data System (ADS)

    Escorza, A.; Boffin, H. M. J.; Jorissen, A.; Van Eck, S.; Siess, L.; Van Winckel, H.; Karinkuzhi, D.; Shetye, S.; Pourbaix, D.

    2017-12-01

    With the availability of parallaxes provided by the Tycho-Gaia Astrometric Solution, it is possible to construct the Hertzsprung-Russell diagram (HRD) of barium and related stars with unprecedented accuracy. A direct result from the derived HRD is that subgiant CH stars occupy the same region as barium dwarfs, contrary to what their designations imply. By comparing the position of barium stars in the HRD with STAREVOL evolutionary tracks, it is possible to evaluate their masses, provided the metallicity is known. We used an average metallicity [Fe/H] = -0.25 and derived the mass distribution of barium giants. The distribution peaks around 2.5 M⊙ with a tail at higher masses up to 4.5 M⊙. This peak is also seen in the mass distribution of a sample of normal K and M giants used for comparison and is associated with stars located in the red clump. When we compare these mass distributions, we see a deficit of low-mass (1 - 2 M⊙) barium giants. This is probably because low-mass stars reach large radii at the tip of the red giant branch, which may have resulted in an early binary interaction. Among barium giants, the high-mass tail is however dominated by stars with barium indices of less than unity, based on a visual inspection of the barium spectral line; that is, these stars have a very moderate barium line strength. We believe that these stars are not genuine barium giants, but rather bright giants, or supergiants, where the barium lines are strengthened because of a positive luminosity effect. Moreover, contrary to previous claims, we do not see differences between the mass distributions of mild and strong barium giants. Full Table A.1 is only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/608/A100

  12. Surface studies of thermionic cathodes and the mechanism of operation of an impregnated tungsten cathode

    NASA Technical Reports Server (NTRS)

    Forman, R.

    1976-01-01

    The surface properties of conventional impregnated cathodes were investigated by the use of Auger spectroscopy and work function measurements, and these were compared with a synthesized barium or barium oxide coated tungsten surface. The barium and barium oxide coated surfaces were prepared by evaporating barium onto a tungsten surface that can be heated to elevated temperatures. Multilayer or monolayer coverages can be investigated using this technique. The results of this study show that the surface of an impregnated tungsten cathode is identical to that observed for a synthesized monolayer or partial monolayer of barium on partially oxidized tungsten, using the criteria of identical Auger patterns and work functions. Desorption measurements of barium from a tungsten surface were also made. These results in conjunction with Auger and work function data were interpreted to show that throughout most of its life an impregnated cathode operating in the range of 1100 C has a partial monolayer rather than a monolayer of barium on its surface.

  13. Status of barium studies in the present era of oncology: Are they a history?

    PubMed Central

    Mahajan, Abhishek; Desai, Subash; Sable, Nilesh Pandurang; Thakur, Meenakshi Haresh

    2016-01-01

    With the advent of the modern imaging technologies, the present era of oncology is seeing steady decline in requests for barium studies due to the many reasons. It is prudent to mention here, that, barium examinations cannot be made obsolete! Our aim to preserve the age old technique of barium studies not only to keep it going on but also for the betterment and appropriate management of the patient. Our goal is not to “save” barium studies simply to keep this technology alive, per se, but rather to preserve barium radiology for the quality in patient care. PMID:28144086

  14. 40 CFR 721.10011 - Barium calcium manganese strontium oxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Barium calcium manganese strontium... Specific Chemical Substances § 721.10011 Barium calcium manganese strontium oxide. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium calcium...

  15. 40 CFR 721.10011 - Barium calcium manganese strontium oxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Barium calcium manganese strontium... Specific Chemical Substances § 721.10011 Barium calcium manganese strontium oxide. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium calcium...

  16. Significantly Enhanced Energy Density in Nanocomposite Capacitors Combining the TiO2 Nanorod Array with Poly(vinylidene fluoride).

    PubMed

    Yao, Lingmin; Pan, Zhongbin; Liu, Shaohui; Zhai, Jiwei; Chen, Haydn H D

    2016-10-05

    A novel inorganic/polymer nanocomposite, using 1-dimensional TiO 2 nanorod array as fillers (TNA) and poly(vinylidene fluoride) (PVDF) as matrix, has been successfully synthesized for the first time. A carefully designed process sequence includes several steps with the initial epitaxial growth of highly oriented TNA on the fluorine-doped tin oxide (FTO) conductive glass. Subsequently, PVDF is embedded into the nanorods by the spin-coating method followed by annealing and quenching processes. This novel structure with dispersive fillers demonstrates a successful compromise between the electric displacement and breakdown strength, resulting in a dramatic increase in the electric polarization which leads to a significant improvement on the energy density and discharge efficiency. The nanocomposites with various height ratios of fillers between the TNA and total film thickness were investigated by us. The results show that nanocomposite with 18% height ratio fillers obtains maximum increase in the energy density (10.62 J cm -3 ) at a lower applied electric field of 340 MV m -1 , and it also illustrates a higher efficiency (>85%) under the electric field less than 100 MV m -1 . Even when the electric field reached 340 MV m -1 , the efficiency of nanocomposites can still maintained at ∼70%. This energy density exceeds most of the previously reported TiO 2 -based nanocomposite values at such a breakdown strength, which provides another promising design for the next generation of dielectric nanocomposite material, by using the highly oriented nanorod array as fillers for the higher energy density capacitors. Additionally, the finite element simulation has been employed to analyze the distribution of electric fields and electric flux density to explore the inherent mechanism of the higher performance of the TNA/PVDF nanocomposites.

  17. Comparison of Barium and Arsenic Concentrations in Well Drinking Water and in Human Body Samples and a Novel Remediation System for These Elements in Well Drinking Water.

    PubMed

    Kato, Masashi; Kumasaka, Mayuko Y; Ohnuma, Shoko; Furuta, Akio; Kato, Yoko; Shekhar, Hossain U; Kojima, Michiyo; Koike, Yasuko; Dinh Thang, Nguyen; Ohgami, Nobutaka; Ly, Thuy Bich; Jia, Xiaofang; Yetti, Husna; Naito, Hisao; Ichihara, Gaku; Yajima, Ichiro

    2013-01-01

    Health risk for well drinking water is a worldwide problem. Our recent studies showed increased toxicity by exposure to barium alone (≤700 µg/L) and coexposure to barium (137 µg/L) and arsenic (225 µg/L). The present edition of WHO health-based guidelines for drinking water revised in 2011 has maintained the values of arsenic (10 µg/L) and barium (700 µg/L), but not elements such as manganese, iron and zinc. Nevertheless, there have been very few studies on barium in drinking water and human samples. This study showed significant correlations between levels of arsenic and barium, but not its homologous elements (magnesium, calcium and strontium), in urine, toenail and hair samples obtained from residents of Jessore, Bangladesh. Significant correlation between levels of arsenic and barium in well drinking water and levels in human urine, toenail and hair samples were also observed. Based on these results, a high-performance and low-cost adsorbent composed of a hydrotalcite-like compound for barium and arsenic was developed. The adsorbent reduced levels of barium and arsenic from well water in Bangladesh and Vietnam to <7 µg/L within 1 min. Thus, we have showed levels of arsenic and barium in humans and propose a novel remediation system.

  18. Comparison of Barium and Arsenic Concentrations in Well Drinking Water and in Human Body Samples and a Novel Remediation System for These Elements in Well Drinking Water

    PubMed Central

    Kato, Masashi; Kumasaka, Mayuko Y.; Ohnuma, Shoko; Furuta, Akio; Kato, Yoko; Shekhar, Hossain U.; Kojima, Michiyo; Koike, Yasuko; Dinh Thang, Nguyen; Ohgami, Nobutaka; Ly, Thuy Bich; Jia, Xiaofang; Yetti, Husna; Naito, Hisao; Ichihara, Gaku; Yajima, Ichiro

    2013-01-01

    Health risk for well drinking water is a worldwide problem. Our recent studies showed increased toxicity by exposure to barium alone (≤700 µg/L) and coexposure to barium (137 µg/L) and arsenic (225 µg/L). The present edition of WHO health-based guidelines for drinking water revised in 2011 has maintained the values of arsenic (10 µg/L) and barium (700 µg/L), but not elements such as manganese, iron and zinc. Nevertheless, there have been very few studies on barium in drinking water and human samples. This study showed significant correlations between levels of arsenic and barium, but not its homologous elements (magnesium, calcium and strontium), in urine, toenail and hair samples obtained from residents of Jessore, Bangladesh. Significant correlation between levels of arsenic and barium in well drinking water and levels in human urine, toenail and hair samples were also observed. Based on these results, a high-performance and low-cost adsorbent composed of a hydrotalcite-like compound for barium and arsenic was developed. The adsorbent reduced levels of barium and arsenic from well water in Bangladesh and Vietnam to <7 µg/L within 1 min. Thus, we have showed levels of arsenic and barium in humans and propose a novel remediation system. PMID:23805262

  19. Effects of chemesthetic stimuli mixtures with barium on swallowing apnea duration.

    PubMed

    Todd, J Tee; Butler, Susan G; Plonk, Drew P; Grace-Martin, Karen; Pelletier, Cathy A

    2012-10-01

    This study tested the hypotheses that swallowing apnea duration (SAD) will increase given barium versus water, chemesthetic stimuli (i.e., water < ethanol, acid, and carbonation) mixed with barium, age (older > younger), and genetic taste differences (supertasters > nontasters). Prospective group design. University Medical Center. Eighty healthy women were identified as nontasters and supertasters, equally comprising two age groups: 18 to 35 years and 60+ years. The KayPentax Swallowing Signals Lab was used to acquire SAD via nasal cannula during individually randomized swallows of 5 mL barium, 2.7% w/v citric acid with barium, carbonation with barium, and 50:50 diluted ethanol with barium. Data were analyzed using path analysis, with the mediator of chemesthetic perception, adjusted for repeated measures. Significant main effects of age (P = .012) and chemesthetic stimuli (P = .014) were found, as well as a significant interaction between chemesthetic stimuli and age (P = .028). Older women had a significantly longer SAD than younger women. Post hoc analyses revealed that barium mixed with ethanol elicited a significantly longer SAD than other bolus conditions, regardless of age group. There were no significant differences in SAD between barium and water conditions, and no significant effect of chemesthetic perception (P > .05). Ethanol added to barium elicited longer SAD compared to plain barium, but not the other chemesthetic conditions. Older women had a longer SAD than younger women in all conditions. These findings may influence design of future studies examining effects of various stimuli on SAD. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  20. Tungsten and Barium Transport in the Internal Plasma of Hollow Cathodes

    NASA Technical Reports Server (NTRS)

    Polk, James E.; Mikellides, Ioannis G.; Katz, Ira; Capece, Angela M.

    2008-01-01

    The effect of tungsten erosion, transport and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from an 8200 hour and a 30,352 hour ion engine wear test. Erosion and subsequent re-deposition of tungsten in the electron emission zone at the downstream end of the insert reduces the porosity of the tungsten matrix, preventing the flow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushedback to the emitter surface by the electric field and drag from the xenon ion flow. Thisbarium ion flux is sufficient to maintain a barium surface coverage at the downstream endgreater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length,so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollowcathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  1. Cross-Selectivity Enhancement of Poly(vinylidene fluoride-hexafluoropropylene)-Based Sensor Arrays for Detecting Acetone and Ethanol.

    PubMed

    Daneshkhah, Ali; Shrestha, Sudhir; Siegel, Amanda; Varahramyan, Kody; Agarwal, Mangilal

    2017-03-15

    Two methods for cross-selectivity enhancement of porous poly(vinylidene fluoride-hexafluoropropylene) (PVDF-HFP)/carbon black (CB) composite-based resistive sensors are provided. The sensors are tested with acetone and ethanol in the presence of humid air. Cross-selectivity is enhanced using two different methods to modify the basic response of the PVDF-HFP/CB sensing platform. In method I, the adsorption properties of PVDF-HFP/CB are altered by adding a polyethylene oxide (PEO) layer or by treating with infrared (IR). In method II, the effects of the interaction of acetone and ethanol are enhanced by adding diethylene carbonate (DEC) or PEO dispersed in DEC (PEO/DEC) to the film. The results suggest the approaches used in method I alter the composite ability to adsorb acetone and ethanol, while in method II, they alter the transduction characteristics of the composite. Using these approaches, sensor relative response to acetone was increased by 89% compared with the PVDF-HFP/CB untreated film, whereas sensor relative response to ethanol could be decreased by 57% or increased by 197%. Not only do these results demonstrate facile methods for increasing sensitivity of PVDF-HFP/CB film, used in parallel they demonstrate a roadmap for enhancing system cross-selectivity that can be applied to separate units on an array. Fabrication methods, experimental procedures and results are presented and discussed.

  2. Cross-Selectivity Enhancement of Poly(vinylidene fluoride-hexafluoropropylene)-Based Sensor Arrays for Detecting Acetone and Ethanol

    PubMed Central

    Daneshkhah, Ali; Shrestha, Sudhir; Siegel, Amanda; Varahramyan, Kody; Agarwal, Mangilal

    2017-01-01

    Two methods for cross-selectivity enhancement of porous poly(vinylidene fluoride-hexafluoropropylene) (PVDF-HFP)/carbon black (CB) composite-based resistive sensors are provided. The sensors are tested with acetone and ethanol in the presence of humid air. Cross-selectivity is enhanced using two different methods to modify the basic response of the PVDF-HFP/CB sensing platform. In method I, the adsorption properties of PVDF-HFP/CB are altered by adding a polyethylene oxide (PEO) layer or by treating with infrared (IR). In method II, the effects of the interaction of acetone and ethanol are enhanced by adding diethylene carbonate (DEC) or PEO dispersed in DEC (PEO/DEC) to the film. The results suggest the approaches used in method I alter the composite ability to adsorb acetone and ethanol, while in method II, they alter the transduction characteristics of the composite. Using these approaches, sensor relative response to acetone was increased by 89% compared with the PVDF-HFP/CB untreated film, whereas sensor relative response to ethanol could be decreased by 57% or increased by 197%. Not only do these results demonstrate facile methods for increasing sensitivity of PVDF-HFP/CB film, used in parallel they demonstrate a roadmap for enhancing system cross-selectivity that can be applied to separate units on an array. Fabrication methods, experimental procedures and results are presented and discussed. PMID:28294961

  3. Thin polymer etalon arrays for high-resolution photoacoustic imaging

    PubMed Central

    Hou, Yang; Huang, Sheng-Wen; Ashkenazi, Shai; Witte, Russell; O’Donnell, Matthew

    2009-01-01

    Thin polymer etalons are demonstrated as high-frequency ultrasound sensors for three-dimensional (3-D) high-resolution photoacoustic imaging. The etalon, a Fabry-Perot optical resonator, consists of a thin polymer slab sandwiched between two gold layers. It is probed with a scanning continuous-wave (CW) laser for ultrasound array detection. Detection bandwidth of a 20-μm-diam array element exceeds 50 MHz, and the ultrasound sensitivity is comparable to polyvinylidene fluoride (PVDF) equivalents of similar size. In a typical photoacoustic imaging setup, a pulsed laser beam illuminates the imaging target, where optical energy is absorbed and acoustic waves are generated through the thermoelastic effect. An ultrasound detection array is formed by scanning the probing laser beam on the etalon surface in either a 1-D or a 2-D configuration, which produces 2-D or 3-D images, respectively. Axial and lateral resolutions have been demonstrated to be better than 20 μm. Detailed characterizations of the optical and acoustical properties of the etalon, as well as photoacoustic imaging results, suggest that thin polymer etalon arrays can be used as ultrasound detectors for 3-D high-resolution photoacoustic imaging applications. PMID:19123679

  4. Fabrication of thin film TiO2 nanotube arrays on Co-28Cr-6Mo alloy by anodization.

    PubMed

    Ni, Jiahua; Frandsen, Christine J; Noh, Kunbae; Johnston, Gary W; He, Guo; Tang, Tingting; Jin, Sungho

    2013-04-01

    Titanium oxide (TiO2) nanotube arrays were prepared by anodization of Ti/Au/Ti trilayer thin film DC sputtered onto forged and cast Co-28Cr-6Mo alloy substrate at 400 °C. Two different types of deposited film structures (Ti/Au/Ti trilayer and Ti monolayer), and two deposition temperatures (room temperature and 400 °C) were compared in this work. The concentrations of ammonium fluoride (NH4F) and H2O in glycerol electrolyte were varied to study their effect on the formation of TiO2 nanotube arrays on a forged and cast Co-28Cr-6Mo alloy. The results show that Ti/Au/Ti trilayer thin film and elevated temperature sputtered films are favorable for the formation of well-ordered nanotube arrays. The optimized electrolyte concentration for the growth of TiO2 nanotube arrays on forged and cast Co-28Cr-6Mo alloy was obtained. This work contains meaningful results for the application of a TiO2 nanotube coating to a CoCr alloy implant for potential next-generation orthopedic implant surface coatings with improved osseointegrative capabilities. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Life Model of Hollow Cathodes Using a Barium Calcium Aluminate Impregnated Tungsten Emitter

    NASA Technical Reports Server (NTRS)

    Kovaleski, S. D.; Burke, Tom (Technical Monitor)

    2001-01-01

    Hollow cathodes with barium calcium aluminate impregnated tungsten emitters for thermionic emission are widely used in electric propulsion. These high current, low power cathodes are employed in ion thrusters, Hall thrusters, and on the International Space Station in plasma contactors. The requirements on hollow cathode life are growing more stringent with the increasing use of electric propulsion technology. The life limiting mechanism that determines the entitlement lifetime of a barium impregnated thermionic emission cathode is the evolution and transport of barium away from the emitter surface. A model is being developed to study the process of barium transport and loss from the emitter insert in hollow cathodes. The model accounts for the production of barium through analysis of the relevant impregnate chemistry. Transport of barium through the approximately static gas is also being treated. Finally, the effect of temperature gradients within the cathode are considered.

  6. Nanoparticles of barium induce apoptosis in human phagocytes

    PubMed Central

    Mores, Luana; França, Eduardo Luzia; Silva, Núbia Andrade; Suchara, Eliane Aparecida; Honorio-França, Adenilda Cristina

    2015-01-01

    Purpose Nutrients and immunological factors of breast milk are essential for newborn growth and the development of their immune system, but this secretion can contain organic and inorganic toxins such as barium. Colostrum contamination with barium is an important issue to investigate because this naturally occurring element is also associated with human activity and industrial pollution. The study evaluated the administration of barium nanoparticles to colostrum, assessing the viability and functional activity of colostral mononuclear phagocytes. Methods Colostrum was collected from 24 clinically healthy women (aged 18–35 years). Cell viability, superoxide release, intracellular Ca2+ release, and phagocyte apoptosis were analyzed in the samples. Results Treatment with barium lowered mononuclear phagocyte viability, increased superoxide release, and reduced intracellular calcium release. In addition, barium increased cell death by apoptosis. Conclusion These data suggest that nanoparticles of barium in colostrum are toxic to cells, showing the importance of avoiding exposure to this element. PMID:26451108

  7. Nanoparticles of barium induce apoptosis in human phagocytes.

    PubMed

    Mores, Luana; França, Eduardo Luzia; Silva, Núbia Andrade; Suchara, Eliane Aparecida; Honorio-França, Adenilda Cristina

    2015-01-01

    Nutrients and immunological factors of breast milk are essential for newborn growth and the development of their immune system, but this secretion can contain organic and inorganic toxins such as barium. Colostrum contamination with barium is an important issue to investigate because this naturally occurring element is also associated with human activity and industrial pollution. The study evaluated the administration of barium nanoparticles to colostrum, assessing the viability and functional activity of colostral mononuclear phagocytes. Colostrum was collected from 24 clinically healthy women (aged 18-35 years). Cell viability, superoxide release, intracellular Ca(2+) release, and phagocyte apoptosis were analyzed in the samples. Treatment with barium lowered mononuclear phagocyte viability, increased superoxide release, and reduced intracellular calcium release. In addition, barium increased cell death by apoptosis. These data suggest that nanoparticles of barium in colostrum are toxic to cells, showing the importance of avoiding exposure to this element.

  8. Bio-based barium alginate film: Preparation, flame retardancy and thermal degradation behavior.

    PubMed

    Liu, Yun; Zhang, Chuan-Jie; Zhao, Jin-Chao; Guo, Yi; Zhu, Ping; Wang, De-Yi

    2016-03-30

    A bio-based barium alginate film was prepared via a facile ionic exchange and casting approach. Its flammability, thermal degradation and pyrolysis behaviors, thermal degradation mechanism were studied systemically by limiting oxygen index (LOI), vertical burning (UL-94), microscale combustion calorimetry (MCC), thermogravimetric analysis (TGA) coupled with Fourier transform infrared analysis (FTIR) and pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS). It showed that barium alginate film had much higher LOI value (52.0%) than that of sodium alginate film (24.5%). Moreover, barium alginate film passed the UL-94 V-0 rating, while the sodium alginate film showed no classification. Importantly, peak of heat release rate (PHRR) of barium alginate film in MCC test was much lower than that of sodium alginate film, suggested that introduction of barium ion into alginate film significantly decreased release of combustible gases. TG-FTIR and Py-GC-MS results indicated that barium alginate produced much less flammable products than that of sodium alginate in whole thermal degradation procedure. Finally, a possible degradation mechanism of barium alginate had been proposed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Do all barium stars have a white dwarf companion?

    NASA Technical Reports Server (NTRS)

    Dominy, J. F.; Lambert, D. L.

    1983-01-01

    International Ultraviolet Explorer short-wavelength, low-dispersion spectra were analyzed for four barium, two mild barium, and one R-type carbon star in order to test the hypothesis that the barium and related giants are produced by mass transfer from a companion now present as a white dwarf. An earlier tentative identification of a white dwarf companion to the mild barium star Zeta Cyg is confirmed. For the other stars, no ultraviolet excess attributable to a white dwarf is seen. Limits are set on the bolometric magnitude and age of a possible white dwarf companion. Since the barium stars do not have obvious progenitors among main-sequence and subgiant stars, mass transfer must be presumed to occur when the mass-gaining star is already on the giant branch. This restriction, and the white dwarf's minimum age, which is greater than 8 x 10 to the 8th yr, determined for several stars, effectively eliminates the hypothesis that mass transfer from an asymptotic giant branch star creates a barium star. Speculations are presented on alternative methods of producing a barium star in a binary system.

  10. Operational verification of a 40-MHz annular array transducer

    PubMed Central

    Ketterling, Jeffrey A.; Ramachandran, Sarayu; Aristizäbal, Orlando

    2006-01-01

    An experimental system to take advantage of the imaging capabilities of a 5-ring polyvinylidene fluoride (PVDF) based annular array is presented. The array has a 6 mm total aperture and a 12 mm geometric focus. The experimental system is designed to pulse a single element of the array and then digitize the received data of all array channels simultaneously. All transmit/receive pairs are digitized and then the data are post-processed with a synthetic focusing technique to achieve an enhanced depth of field (DOF). The performance of the array is experimentally tested with a wire phantom consisting of 25-μm diameter wires diagonally spaced at 1 mm by 1 mm intervals. The phantom permitted the efficacy of the synthetic focusing algorithm to be tested and was also used for two-way beam characterization. Experimental results are compared to a spatial impulse response method beam simulation. After synthetic focusing, the two-way echo amplitude was enhanced over the range of 8 to 19 mm and the 6-dB DOF spanned from 9 to 15 mm. For a wire at a fixed axial depth, the relative time delays between transmit/receive ring pairs agreed with theoretical predictions to within ± 2 ns. To further test the system, B-mode images of an excised bovine eye are rendered. PMID:16555771

  11. Barium versus nonbarium stimuli: differences in taste intensity, chemesthesis, and swallowing behavior in healthy adult women.

    PubMed

    Nagy, Ahmed; Steele, Catriona M; Pelletier, Cathy A

    2014-06-01

    The authors examined the impact of barium on the perceived taste intensity of 7 different liquid tastant stimuli and the modulatory effect that these differences in perceived taste intensity have on swallowing behaviors. Participants were 80 healthy women, stratified by age group (<40; >60) and genetic taste status (supertasters; nontasters). Perceived taste intensity and chemesthetic properties (fizziness; burning-stinging) were rated for 7 tastant solutions (each prepared with and without barium) using the general Labeled Magnitude Scale. Tongue-palate pressures and submental surface electromyography (sEMG) were simultaneously measured during swallowing of these same randomized liquids. Path analysis differentiated the effects of stimulus, genetic taste status, age, barium condition, taste intensity, and an effortful saliva swallow strength covariate on swallowing. Barium stimuli were rated as having reduced taste intensity compared with nonbarium stimuli. Barium also dampened fizziness but did not influence burning-stinging sensation. The amplitudes of tongue-palate pressure or submental sEMG did not differ when swallowing barium versus nonbarium stimuli. Despite impacting taste intensity, the addition of barium to liquid stimuli does not appear to alter behavioral parameters of swallowing. Barium solutions can be considered to elicit behaviors that are similar to those used with nonbarium liquids outside the assessment situation.

  12. Barium Peritonitis in Small Animals

    PubMed Central

    KO, Jae Jin; MANN, F. A. (Tony)

    2014-01-01

    ABSTRACT Barium peritonitis is extremely rare, but is difficult to treat and may be life-threatening. Barium suspension leakage from the gastrointestinal tract into the abdominal cavity has a time-dependent and synergistically deleterious effect in patients who have generalized bacterial peritonitis. The severity of barium peritonitis is dependent on the quantity of barium in the abdominal cavity. Barium sulfate leakage results in hypovolemia and hypoproteinemia by worsening the exudation of extracellular fluid and albumin. Abdominal fluid analysis is a useful and efficient method to diagnose barium peritonitis. Serial radiographs may not be a reliable or timely diagnostic technique. Initial aggressive fluid resuscitation and empirical broad-spectrum antibiotic treatment should be instituted promptly, followed quickly by celiotomy. During exploratory surgical intervention, copious irrigation and direct wiping with gauze are employed to remove as much barium as possible. Omentectomy should be considered when needed to expedite barium removal. Despite aggressive medical and surgical treatments, postoperative prognosis is guarded to poor due to complications, such as acute vascular shock, sepsis, diffuse peritonitis, hypoproteninemia, electrolyte imbalance, cardiac arrest, small bowel obstruction related to progression of granulomas and adhesions in the abdominal cavity. Therefore, intensive postoperative monitoring and prompt intervention are necessary to maximize chances for a positive outcome. For those that do survive, small bowel obstruction is a potential consequence due to progression of abdominal adhesions. PMID:24430662

  13. Endotrophic Calcium, Strontium, and Barium Spores of Bacillus megaterium and Bacillus cereus1

    PubMed Central

    Foerster, Harold F.; Foster, J. W.

    1966-01-01

    Foerster, Harold F. (The University of Texas, Austin), and J. W. Foster. Endotrophic calcium, strontium, and barium spores of Bacillus megaterium and Bacillus cereus. J. Bacteriol. 91:1333–1345. 1966.—Spores were produced by washed vegetative cells suspended in deionized water supplemented with CaCl2, SrCl2, or BaCl2. Normal, refractile spores were produced in each case; a portion of the barium spores lost refractility and darkened. Thin-section electron micrographs revealed no apparent anatomical differences among the three types of spores. Analyses revealed that the different spore types were enriched specifically in the metal to which they were exposed during sporogenesis. The calcium content of the strontium and the barium spores was very small. From binary equimolar mixtures of the metal salts, endotrophic spores accumulated both metals to nearly the same extent. Viability of the barium spores was considerably less than that of the other two types. Strontium and barium spores were heat-resistant; however, calcium was essential for maximal heat resistance. Significant differences existed in the rates of germination; calcium spores germinated fastest, strontium spores were slower, and barium spores were slowest. Calcium-barium and calcium-strontium spores germinated readily. Endotrophic calcium and strontium spores germinated without the prior heat activation essential for growth spores. Chemical germination of the different metal-type spores with n-dodecylamine took place at the same relative rates as physiological germination. Heat-induced release of dipicolinic acid occurred much faster with barium and strontium spores than with calcium spores. The washed “coat fraction” from disrupted spores contained little of the spore calcium but most of the spore barium. The metal in this fraction was released by dilute acid. The demineralized coats reabsorbed calcium and barium at neutral pH. Images PMID:4956334

  14. Hematological, biochemical, and histopathological impacts of barium chloride and barium carbonate accumulation in soft tissues of male Sprague-Dawley rats.

    PubMed

    Mohammed, Amany Tharwat; Ismail, Hager Tarek H

    2017-12-01

    The present study was designed to investigate the hematotoxicity, sero-biochemical and histological changes due to the accumulation of BaCl 2 and BaCO 3 , the most important barium salts in our daily lives, in different soft tissues including the liver, kidney, heart, and spleen of adult rats after an oral exposure for 30 consecutive days, and to explain the different mechanisms by which this metal can exert these impacts. For this purpose, adult male rats were divided into three main groups of 15 animals each: group I, serving as controls, group II, receiving BaCl 2 orally in a dose of 179 mg barium/kg b.wt, and group III, receiving BaCO 3 orally in a dose of 418 mg barium/kg b.wt. for 30 consecutive days. Obviously, normocytic normochromic anemia was evident in both barium groups. Serum biochemical analysis revealed significant declines in glutathione peroxidase, catalase, superoxide dismutase, and urea with significant elevations in malondialdehyde, lactate dehydrogenase, and creatine kinase levels. Hyperphosphatemia, hypokalemia, hypocalcemia, and hypochloremia were also evident in both barium groups. Besides, residual analysis of both barium salts in different body organs revealed significantly abundant barium residues in the liver, spleen, heart, and kidney, respectively in both barium salts groups. Moreover, splenic tissue showed hemosiderosis, peritubular congestion, and necrotic glomeruli with intratubular hemorrhage. Sever subepicardial congestion with intramuscular edema was evident in the heart. In conclusion, BaCl 2 and BaCO 3 were able to deliver mortalities, antioxidant enzymes exhaustion, and a sort of normocytic normochromic anemia, as well as marked disturbances in cardiac, hepatic, and renal functions due to the accumulation of these two salts in the soft tissues. Therefore, these results demonstrate the unrecognized toxicity of those two barium salts due to their accumulation in various soft tissues of the body and so, this needs to reconsider about barium exposure.

  15. Postprandial fullness correlates with rapid inflow of gastric content into duodenum but not with chronic gastritis

    PubMed Central

    2011-01-01

    Background The aim of this study is evaluating the correlation of postprandial fullness with chronic gastritis or rapid inflow of gastric content into duodenum, based on double-contrast barium X-ray imaging. Methods 253 healthy subjects who underwent upper gastrointestinal barium X-ray examination were analyzed. Chronic gastritis was judged from mucosal atrophy and hypertrophic thickened folds on barium X-ray images. For the gastric excretion, the tips of barium flow on the single-contrast frontal barium X-ray images of the stomach were classified into four categories; V type (all the barium remained in the stomach), V-H type (some barium had flowed into the duodenum but the tip of barium remained in the proximal half of the duodenal bulb), H-V type (some barium had flowed into the duodenum and the tip of barium was in the distal half of duodenal the bulb, but no barium was observed in the descending part of the duodenum), and H type (some barium had flowed into the descending part of the duodenum). The chi-square test and Cochran-Mantel-Haenzel test were used for evaluation. Results Chronic gastritis was observed in 72 subjects, among which 21 subjects (29.2%) presented with postprandial fullness. For the remaining 181 subjects without chronic gastritis, 53 subjects (29.3%) complained of postprandial fullness. There is no significant correlation between chronic gastritis and postprandial fullness (p = 0.973). For the rapid flow of gastric content into duodenum, all the 253 subjects comprised 136 subjects with V type (in the stomach), 40 subjects with V-H type (in the proximal half of the duodenal bulb), 21 subjects with H-V type (in the distal half of the duodenal bulb), and 56 subjects with H type (in the descending part of the duodenum). Postprandial fullness was present in 30 subjects with V type (22.1%), 9 subjects with V-H type (22.5%), 8 subjects with H-V type (38.1%), and 27 subjects with H type (48.2%). There is a distinct correlation between postprandial fullness and gastric barium excretion on barium X-ray imaging (p = 0.002). Conclusions Bothersome postprandial fullness correlates with rapid inflow of gastric content into duodenum, but not with chronic gastritis. PMID:22189089

  16. Luminescence and scintillation properties of BaF2sbnd Ce transparent ceramic

    NASA Astrophysics Data System (ADS)

    Luo, Junming; Sahi, Sunil; Groza, Michael; Wang, Zhiqiang; Ma, Lun; Chen, Wei; Burger, Arnold; Kenarangui, Rasool; Sham, Tsun-Kong; Selim, Farida A.

    2016-08-01

    Cerium doped Barium Fluoride (BaF2sbnd Ce) transparent ceramic was fabricated and its luminescence and scintillation properties were studied. The photoluminescence shows the emission peaks at 310 nm and 323 nm and is related to the 5d-4f transitions in Ce3+ ion. Photo peak at 511 keV and 1274 keV were obtained with BaF2sbnd Ce transparent ceramic for Na-22 radioisotopes. Energy resolution of 13.5% at 662 keV is calculated for the BaF2sbnd Ce transparent ceramic. Light yield of 5100 photons/MeV was recorded for BaF2sbnd Ce(0.2%) ceramic and is comparable to its single crystal counterpart. Scintillation decay time measurements shows fast component of 58 ns and a relatively slow component of 434 ns under 662 keV gamma excitation. The slower component in BaF2sbnd Ce(0.2%) ceramic is about 200 ns faster than the STE emission in BaF2 host and is associated with the dipole-dipole energy transfer from the host matrix to Ce3+ luminescence center.

  17. Water chemistry of surface waters affected by the Fourmile Canyon wildfire, Colorado, 2010-2011

    USGS Publications Warehouse

    McCleskey, R. Blaine; Writer, Jeffrey H.; Murphy, Sheila F.

    2012-01-01

    In September 2010, the Fourmile Canyon fire burned about 23 percent of the Fourmile Creek watershed in Boulder County, Colo. Water-quality sampling of Fourmile Creek began within a month after the wildfire to assess its effects on surface-water chemistry. Water samples were collected from five sites along Fourmile Creek (above, within, and below the burned area) monthly during base flow, twice weekly during snowmelt runoff, and at higher frequencies during storm events. Stream discharge was also monitored. Water-quality samples were collected less frequently from an additional 6 sites on Fourmile Creek, from 11 tributaries or other inputs, and from 3 sites along Boulder Creek. The pH, electrical conductivity, temperature, specific ultraviolet absorbance, total suspended solids, and concentrations (dissolved and total) of major cations (calcium, magnesium, sodium, and potassium), anions (chloride, sulfate, alkalinity, fluoride, and bromide), nutrients (nitrate, ammonium, and phosphorus), trace metals (aluminum, arsenic, boron, barium, beryllium, cadmium, cobalt, chromium, copper, iron, mercury, lithium, manganese, molybdenum, nickel, lead, rubidium, antimony, selenium, strontium, vanadium, and zinc), and dissolved organic carbon are here reported for 436 samples collected during 2010 and 2011.

  18. NASA PS400: A New Temperature Solid Lubricant Coating for High Temperature Wear Applications

    NASA Technical Reports Server (NTRS)

    DellaCorte, C.; Edmonds, B. J.

    2009-01-01

    A new solid lubricant coating, NASA PS400, has been developed for high temperature tribological applications. This plasma sprayed coating is a variant of the patented PS304 coating and has been formulated to provide higher density, smoother surface finish and better dimensional stability than PS304. PS400 is comprised of a nickel-molybdenum binder that provides strength, creep resistance and extreme oxidative and dimensional stability. Chromium oxide, silver and barium-calcium fluoride eutectic are added to the binder to form PS400.Tribological properties were evaluated with a pin-on-disk test rig in sliding contact to 650 C. Coating material samples were exposed to air, argon and vacuum at 760 C followed by cross section microscopic analysis to assess microstructure stability. Oil-Free microturbine engine hot section foil bearing tests were undertaken to assess PS400 s suitability for hot foil gas bearing applications. The preliminary results indicate that PS400 exhibits tribological characteristics comparable to the PS304 coating but with enhanced creep resistance and dimensional stability suitable for demanding, dynamic applications.

  19. 1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

  20. Synthesis, structural, characterization and dielectric spectroscopy of PVDF - BaTiO3 polymer composite

    NASA Astrophysics Data System (ADS)

    Kulkarni, S. S.; Belavi, P. B.; Khadke, U. V.

    2018-05-01

    In this paper we report the method of synthesis of ferroelectric polymer Polyvinyldene fluoride (PVDF) and Barium Titanate (BaTiO3) composite self supporting thin films and its dielectric response. BaTiO3 was synthesized by solid state reaction method. The PVDF - BaTiO3 polymer composites with various concentrations were synthesized by solution mixing method using Dimethylformadide (DMF) as a solvent. The phase transformation and surface methodology of the prepared composites were characterized by X-ray diffraction (XRD) and Scanning Electron Microscopy (SEM) respectively. The XRD pattern confirms the formation of tetragonal pervoskite structure of ferroelectric phase. The XRD pattern shows the proper mixing of BaTiO3 particles intestinally and found to be improving its crystallinity with increase of BaTiO3 composition in the PVDF matrix. The dielectric properties of the composites as a function of frequency were computed using impedance analyzer. The dielectric constant decreases with increase of frequency shows the Maxwell - Wagner type of interfacial polarization in accordance with Koop's phenomenological theory.

  1. Barium enema

    MedlinePlus

    Lower gastrointestinal series; Lower GI series; Colorectal cancer - lower GI series; Colorectal cancer - barium enema; Crohn disease - lower GI series; Crohn disease - barium enema; Intestinal blockage - lower GI series; Intestinal ...

  2. 21 CFR 201.304 - Tannic acid and barium enema preparations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Tannic acid and barium enema preparations. 201.304... Tannic acid and barium enema preparations. (a) It has become a widespread practice for tannic acid to be added to barium enemas to improve X-ray pictures. Tannic acid is capable of causing diminished liver...

  3. 21 CFR 201.304 - Tannic acid and barium enema preparations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Tannic acid and barium enema preparations. 201.304... Tannic acid and barium enema preparations. (a) It has become a widespread practice for tannic acid to be added to barium enemas to improve X-ray pictures. Tannic acid is capable of causing diminished liver...

  4. 21 CFR 201.304 - Tannic acid and barium enema preparations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 4 2014-04-01 2014-04-01 false Tannic acid and barium enema preparations. 201.304... Tannic acid and barium enema preparations. (a) It has become a widespread practice for tannic acid to be added to barium enemas to improve X-ray pictures. Tannic acid is capable of causing diminished liver...

  5. 49 CFR 173.182 - Barium azide-50 percent or more water wet.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Barium azide-50 percent or more water wet. 173.182 Section 173.182 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... Class 1 and Class 7 § 173.182 Barium azide—50 percent or more water wet. Barium azide—50 percent or more...

  6. Barium release system

    NASA Technical Reports Server (NTRS)

    Lewis, B. W.; Stokes, C. S.; Smith, E. W.; Murphy, W. J. (Inventor)

    1973-01-01

    A chemical system is described for releasing a good yield of free barium neutral atoms and barium ions in the upper atmosphere and interplanetary space for the study of the geophysical properties of the medium. The barium is released in the vapor phase so that it can be ionized by solar radiation and also be excited to emit resonance radiation in the visible range. The ionized luminous cloud of barium becomes a visible indication of magnetic and electrical characteristics in space and allows determination of these properties over relatively large areas at a given time.

  7. Evaluation of gastrointestinal tract transit times using barium-impregnated polyethylene spheres and barium sulfate suspension in a domestic pigeon (Columba livia) model.

    PubMed

    Bloch, Rebecca A; Cronin, Kimberly; Hoover, John P; Pechman, Robert D; Payton, Mark E

    2010-03-01

    Barium impregnated polyethylene spheres (BIPS) are used in small animal medicine as an alternative to barium sulfate for radiographic studies of the gastrointestinal tract. To determine the usefulness of BIPS as an alternative to barium suspension in measuring gastrointestinal (GI) transit time for avian species, ventrodorsal radiographs were used to follow the passage of BIPS and 30% barium sulfate suspension through the GI tracts of domestic pigeons (Columba livia). Gastrointestinal transit times of thirty 1.5-mm BIPS administered in moistened gelatin capsules and 30% barium sulfate suspension gavaged into the crop were compared in 6 pigeons. Although the barium suspension passed out of the GI tract of all pigeons within 24 hours, the 1.5-mm BIPS remained in the ventriculus for 368.0 +/- 176.8 hours and did not clear the GI tract for 424.0 +/- 204.6 hours. Although the times for passage of BIPS and 30% barium sulfate suspension from the crop into the ventriculus were not significantly different (P = .14), the times for passage of BIPS from the ventriculus into the large intestine-cloaca and for clearance from the GI tract of the pigeons were significantly longer (P < .001) than for the 30% barium sulfate suspension. From the results of this study, we conclude that BIPS are not useful for radiographically evaluating GI transit times in pigeons and are unlikely to be useful in other avian species that have a muscular ventriculus. BIPS may or may not be useful for evaluating GI transit times in species that lack a muscular ventriculus.

  8. The effect of barium on perceptions of taste intensity and palatability.

    PubMed

    Dietsch, Angela M; Solomon, Nancy Pearl; Steele, Catriona M; Pelletier, Cathy A

    2014-02-01

    Barium may affect the perception of taste intensity and palatability. Such differences are important considerations in the selection of dysphagia assessment strategies and interpretation of results. Eighty healthy women grouped by age (younger, older) and genetic taste status (supertaster, nontaster) rated intensity and palatability for seven tastants prepared in deionized water with and without 40 % w/v barium: noncarbonated and carbonated water, diluted ethanol, and high concentrations of citric acid (sour), sodium chloride (salty), caffeine (bitter), and sucrose (sweet). Mixed-model analyses explored the effects of barium, taster status, and age on perceived taste intensity and acceptability of stimuli. Barium was associated with lower taste intensity ratings for sweet, salty, and bitter tastants, higher taste intensity in carbonated water, and lower palatability in water, sweet, sour, and carbonated water. Older subjects reported lower palatability (all barium samples, sour) and higher taste intensity scores (ethanol, sweet, sour) compared to younger subjects. Supertasters reported higher taste intensity (ethanol, sweet, sour, salty, bitter) and lower palatability (ethanol, salty, bitter) than nontasters. Refusal rates were highest for younger subjects and supertasters, and for barium (regardless of tastant), bitter, and ethanol. Barium suppressed the perceived intensity of some tastes and reduced palatability. These effects are more pronounced in older subjects and supertasters, but younger supertasters are least likely to tolerate trials of barium and strong tastant solutions.

  9. 40 CFR 721.10010 - Barium manganese oxide (BaMnO3).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Substances § 721.10010 Barium manganese oxide (BaMnO3). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium manganese oxide (BaMnO3) (PMN P-00... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Barium manganese oxide (BaMnO3). 721...

  10. 40 CFR 721.10010 - Barium manganese oxide (BaMnO3).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Substances § 721.10010 Barium manganese oxide (BaMnO3). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium manganese oxide (BaMnO3) (PMN P-00... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Barium manganese oxide (BaMnO3). 721...

  11. 40 CFR 721.10010 - Barium manganese oxide (BaMnO3).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Barium manganese oxide (BaMnO3). 721... Substances § 721.10010 Barium manganese oxide (BaMnO3). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium manganese oxide (BaMnO3) (PMN P-00...

  12. 40 CFR 721.10010 - Barium manganese oxide (BaMnO3).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Barium manganese oxide (BaMnO3). 721... Substances § 721.10010 Barium manganese oxide (BaMnO3). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium manganese oxide (BaMnO3) (PMN P-00...

  13. Evidence against barium in the mushroom Trogia venenata as a cause of sudden unexpected deaths in Yunnan, China.

    PubMed

    Zhang, Ying; Li, Yanchun; Wu, Gang; Feng, Bang; Yoell, Shanze; Yu, Zefen; Zhang, Keqin; Xu, Jianping

    2012-12-01

    This study examined barium concentrations in the mushroom Trogia venenata, the leading culprit for sudden unexpected deaths in Yunnan, southwest China. We found that barium concentrations in T. venenata from Yunnan were low and comparable to other foods, inconsistent with barium concentrations in this mushroom as a significant contributor to these deaths.

  14. 40 CFR 721.10010 - Barium manganese oxide (BaMnO3).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Barium manganese oxide (BaMnO3). 721... Substances § 721.10010 Barium manganese oxide (BaMnO3). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium manganese oxide (BaMnO3) (PMN P-00...

  15. APPARATUS FOR THE PRODUCTION OF LITHIUM METAL

    DOEpatents

    Baker, P.S.; Duncan, F.R.; Greene, H.B.

    1961-08-22

    Methods and apparatus for the production of high-purity lithium from lithium halides are described. The apparatus is provided for continuously contacting a molten lithium halide with molten barium, thereby forming lithium metal and a barium halide, establishing separate layers of these reaction products and unreacted barium and lithium halide, and continuously withdrawing lithium and barium halide from the reaction zone. (AEC)

  16. Data Acquisition Visualization Development for the MAJORANA DEMONSTRATOR

    NASA Astrophysics Data System (ADS)

    Wendlandt, Laura; Howe, Mark; Wilkerson, John; Majorana Collaboration

    2013-10-01

    The MAJORANA Project is building an array of germanium detectors with very low backgrounds in order to search for neutrinoless double-beta decay, a rare process that, if detected, would give us information about neutrinos. This decay would prove that neutrinos are their own anti-particles, would show that lepton number is not conserved, and would help determine absolute neutrino mass. An object-oriented, data acquisition software program known as ORCA (Object-oriented Real-time Control and Acquisition) will be used to collect data from the array. This paper describes the implementation of computer visualizations for detector calibrations, as well as tools for more general computer modeling in ORCA. Specifically, it details software that converts a CAD file to OpenGL, which can be used in ORCA. This paper also contains information about using a barium-133 source to take measurements from various locations around the detector, to better understand how data varies with detector crystal orientation. Work made possible by National Science Foundation Award OCI-1155614.

  17. Design, testing, fabrication and launch support of a liquid chemical barium release payload (utilizing the liquid fluorine-barium salt/hydrazine system)

    NASA Technical Reports Server (NTRS)

    Stokes, C. S.; Smith, E. W.; Murphy, W. J.

    1972-01-01

    A payload was designed which included a cryogenic oxidizer tank, a fuel tank, and burner section. Release of 30 lb of chemicals was planned to occur in 2 seconds at the optimum oxidizer to fuel ratio. The chemicals consisted of 17 lb of liquid fluorine oxidizer and 13 lb of hydrazine-barium salt fuel mixture. The fuel mixture was 17% barium chloride, 16% barium nitrate, and 67% hydrazine, and contained 2.6 lb of available barium. Two significant problem areas were resolved during the program: explosive valve development and burner operation. The release payload was flight tested, from Wallops Island, Virginia. The release took place at an altitude of approximately 260 km. The release produced a luminous cloud which expanded very rapidly, disappearing to the human eye in about 20 seconds. Barium ion concentration slowly increased over a wide area of sky until measurements were discontinued at sunrise (about 30 minutes).

  18. Barium and manganese-doped zinc silicate rods prepared by mesoporous template route and their luminescence property

    NASA Astrophysics Data System (ADS)

    Dang, Lingyan; Tian, Chen; Zhao, Shifeng; Lu, Qingshan

    2018-06-01

    Barium and manganese-doped zinc silicates was prepared under hydrothermal treatment by mesoporous template route employing mesoporous silica as an active template. The sample displays a rod-like morphology with a mean diameter of ∼40 nm and a mean length of ∼450 nm, which inherits the characteristics of mesoporous silica. The individual rods show single crystalline and assemble into bundle-like hierarchical structure along the channels of the mesoporous silica. When barium ions together with manganese ions are co-doped in zinc silicate, the green emission corresponding to manganese ions display a significant enhancement, especially for the sample with the barium doping concentration of 0.08, which indicates that an energy transfer from barium to manganese ions takes place. With further increasing barium concentration from 0.08 to 0.10, the recombination between the defects related to barium and the excitation states of the manganese dominates accompanying non-radiative transitions which can reduce the emission efficiency.

  19. Surface studies of barium and barium oxide on tungsten and its application to understanding the mechanism of operation of an impregnated tungsten cathode

    NASA Technical Reports Server (NTRS)

    Forman, R.

    1976-01-01

    Surface studies have been made of multilayer and monolayer films of barium and barium oxide on a tungsten substrate. The purpose of the investigation was to synthesize the surface conditions that exist on an activated impregnated tungsten cathode and obtain a better understanding of the mechanism of operation of such cathodes. The techniques employed in these measurements were Auger spectroscopy and work-function measurements. The results of this study show that the surface of an impregnated cathode is identical to that observed for a synthesized monolayer or partial monolayer of barium on oxidized tungsten by evaluating Auger spectra and work-function measurements. Data obtained from desorption studies of barium monolayers on a tungsten substrate in conjunction with Auger and work-function results have been interpreted to show that throughout most of its life an impreganated cathode has a partial monolayer, rather than a monolayer, of barium on its surface.

  20. Development of an all-metal thick film cost effective metallization system for solar cells

    NASA Technical Reports Server (NTRS)

    Ross, B.; Parker, J.

    1983-01-01

    Improved thick film solar cell contacts for the high volume production of low cost silicon solar arrays are needed. All metal screenable pastes made from economical base metals and suitable for application to low to high conductivity silicon were examined. Silver fluoride containing copper pastes and fluorocarbon containing copper pastes were discussed. The effect of hydrogen on the adhesion of metals to silicon was investigated. A cost analysis of various paste materials is provided.

  1. New techniques for positron emission tomography in the study of human neurological disorders for the period June 15, 1987 through December 14, 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhl, D.E.

    1987-09-01

    A brief progress report is presented describing the preparation of /sup 11/C-scopolamine, /sup 17/F-fluoromethane and /sup 18/F-tetraalkylammonium fluoride. The application of /sup 11/C-scopolamine to map cholinergic receptors in normal human brain. Additional studies entitled ''The Automated Arterial Blood Sampling Systems for PET'' and ''Investigations of Array Processor Based High-Speed Parameter Estimation for Tracer Kinetic Modeling'' are also described. (DT)

  2. Effect of barium on diffusion of sodium in borosilicate glass.

    PubMed

    Mishra, R K; Kumar, Sumit; Tomar, B S; Tyagi, A K; Kaushik, C P; Raj, Kanwar; Manchanda, V K

    2008-08-15

    Diffusion coefficients of sodium in barium borosilicate glasses having varying concentration of barium were determined by heterogeneous isotopic exchange method using (24)Na as the radiotracer for sodium. The measurements were carried out at various temperatures (748-798 K) to obtain the activation energy (E(a)) of diffusion. The E(a) values were found to increase with increasing barium content of the glass, indicating that introduction of barium in the borosilicate glass hinders the diffusion of alkali metal ions from the glass matrix. The results have been explained in terms of the electrostatic and structural factors, with the increasing barium concentration resulting in population of low energy sites by Na(+) ions and, plausibly, formation of more tight glass network. The leach rate measurements on the glass samples show similar trend.

  3. Battery-powered thin film deposition process for coating telescope mirrors in space

    NASA Astrophysics Data System (ADS)

    Sheikh, David A.

    2016-07-01

    Aluminum films manufactured in the vacuum of space may increase the broadband reflectance response of a space telescope operating in the EUV (50-nm to 115-nm) by eliminating absorbing metal-fluorides and metal-oxides, which significantly reduce aluminum's reflectance below 115-nm. Recent developments in battery technology allow small lithium batteries to rapidly discharge large amounts of energy. It is therefore conceivable to power an array of resistive evaporation filaments in a space environment, using a reasonable mass of batteries and other hardware. This paper presents modeling results for coating thickness as a function of position, for aluminum films made with a hexagonal array of battery powered evaporation sources. The model is based on measured data from a single battery-powered evaporation source.

  4. Comparison of electrically driven lasers for space power transmission

    NASA Technical Reports Server (NTRS)

    Deyoung, R. J.; Lee, J. H.; Williams, M. D.; Schuster, G.; Conway, E. J.

    1988-01-01

    High-power lasers in space could provide power for a variety of future missions such as spacecraft electric power requirements and laser propulsion. This study investigates four electrically pumped laser systems, all scaled to 1-MW laser output, that could provide power to spacecraft. The four laser systems are krypton fluoride, copper vapor, laser diode array, and carbon dioxide. Each system was powered by a large solar photovoltaic array which, in turn, provided power for the appropriate laser power conditioning subsystem. Each system was block-diagrammed, and the power and efficiency were found for each subsystem block component. The copper vapor system had the lowest system efficiency (6 percent). The CO2 laser was found to be the most readily scalable but has the disadvantage of long laser wavelength.

  5. Thermochemical hydrogen production via a cycle using barium and sulfur - Reaction between barium sulfide and water

    NASA Technical Reports Server (NTRS)

    Ota, K.; Conger, W. L.

    1977-01-01

    The reaction between barium sulfide and water, a reaction found in several sulfur based thermochemical cycles, was investigated kinetically at 653-866 C. Gaseous products were hydrogen and hydrogen sulfide. The rate determining step for hydrogen formation was a surface reaction between barium sulfide and water. An expression was derived for the rate of hydrogen formation.

  6. Evidence against Barium in the Mushroom Trogia venenata as a Cause of Sudden Unexpected Deaths in Yunnan, China

    PubMed Central

    Zhang, Ying; Li, Yanchun; Wu, Gang; Feng, Bang; Yoell, Shanze; Yu, Zefen; Zhang, Keqin

    2012-01-01

    This study examined barium concentrations in the mushroom Trogia venenata, the leading culprit for sudden unexpected deaths in Yunnan, southwest China. We found that barium concentrations in T. venenata from Yunnan were low and comparable to other foods, inconsistent with barium concentrations in this mushroom as a significant contributor to these deaths. PMID:23042168

  7. Sorption of strontium-90 from fresh waters during sulfate modification of barium manganite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryzhen`kov, A.P.; Egorov, Yu.V.

    1995-11-01

    Recovery of strontium-90 with barium manganite from fresh waters (natural fresh waters of open basins) can be increased by adding agents that contain sulfate ions and thus modify the sorbent and chemically bind the sorbate. The treatment results in a heterogeneous anion-exchange transformation of barium manganite into barium sulfate-manganese dioxide and in simultaneous absorptive coprecipitation of strontium sulfate (microcomponent).

  8. Coastal barium cycling at the West Antarctic Peninsula

    NASA Astrophysics Data System (ADS)

    Pyle, K. M.; Hendry, K. R.; Sherrell, R. M.; Meredith, M. P.; Venables, H.; Lagerström, M.; Morte-Ródenas, A.

    2017-05-01

    Barium cycling in the ocean is associated with a number of processes, including the production and recycling of organic matter, freshwater fluxes, and phenomena that affect alkalinity. As a result, the biogeochemical cycle of barium offers insights into past and present oceanic conditions, with barium currently used in various forms as a palaeoproxy for components of organic and inorganic carbon storage, and as a quasi-conservative water mass tracer. However, the nature of the oceanic barium cycle is not fully understood, particularly in cases where multiple processes may be interacting simultaneously with the dissolved and particulate barium pools. This is particularly the case in coastal polar regions such as the West Antarctic Peninsula, where biological drawdown and remineralisation occur in tandem with sea ice formation and melting, glacial meltwater input, and potential fluxes from shelf sediments. Here, we use a high-precision dataset of dissolved barium (Bad) from a grid of stations adjacent to the West Antarctic Peninsula in conjunction with silicic acid (Si(OH)4), the oxygen isotope composition of water, and salinity measurements, to determine the relative control of various coastal processes on the barium cycle throughout the water column. There is a strong correlation between Bad and Si(OH)4 present in deeper samples, but nevertheless persists significantly in surface waters. This indicates that the link between biogenic opal and barium is not solely due to barite precipitation and dissolution at depth, but is supplemented by an association between Bad and diatom tests in surface waters, possibly due to barite formation within diatom-dominated phytodetritus present in the photic zone. Sea-ice meltwater appears to exert a significant secondary control on barium concentrations, likely due to non-conservative biotic or abiotic processes acting as a sink for Bad within the sea ice itself, or sea-ice meltwater stimulating non-siliceous productivity that acts as a Bad sink. Meteoric water input, conversely, exerts little or no control on local barium levels, indicating that glacial meltwater is not a significant coastal source of barium to the West Antarctic Peninsula shelf waters.

  9. Generation and use of high power 213 nm and 266 nm laser radiation and tunable 210-400 nm laser radiation with BBO crystal matrix array

    DOEpatents

    Gruen, Dieter M.

    2000-01-01

    A 213 nm laser beam is capable of single photon ablative photodecomposition for the removal of a polymer or biological material substrate. Breaking the molecular bonds and displacing the molecules away from the substrate in a very short time period results in most of the laser photon energy being carried away by the displaced molecules, thus minimizing thermal damage to the substrate. The incident laser beam may be unfocussed and is preferably produced by quintupling the 1064 nm radiation from a Nd:YAG solid state laser, i.e., at 213 nm. In one application, the 213 nm laser beam is expanded in cross section and directed through a plurality of small beta barium borate (BBO) crystals for increasing the energy per photon of the laser radiation directed onto the substrate. The BBO crystals are arranged in a crystal matrix array to provide a large laser beam transmission area capable of accommodating high energy laser radiation without damaging the BBO crystals. The BBO crystal matrix array may also be used with 266 nm laser radiation for carrying out single or multi photon ablative photodecomposition. The BBO crystal matrix array may also be used in an optical parametric oscillator mode to generate high power tunable laser radiation in the range of 210-400 nm.

  10. Barium enema (image)

    MedlinePlus

    A barium enema is performed to examine the walls of the colon. During the procedure, a well lubricated enema tube is inserted gently into the rectum. The barium, a radiopaque (shows up on X-ray) contrast ...

  11. Development of biomonitoring equivalents for barium in urine and plasma for interpreting human biomonitoring data.

    PubMed

    Poddalgoda, Devika; Macey, Kristin; Assad, Henry; Krishnan, Kannan

    2017-06-01

    The objectives of the present work were: (1) to assemble population-level biomonitoring data to identify the concentrations of urinary and plasma barium across the general population; and (2) to derive biomonitoring equivalents (BEs) for barium in urine and plasma in order to facilitate the interpretation of barium concentrations in the biological matrices. In population level biomonitoring studies, barium has been measured in urine in the U.S. (NHANES study), but no such data on plasma barium levels were identified. The BE values for plasma and urine were derived from U.S. EPA's reference dose (RfD) of 0.2 mg/kg bw/d, based on a lower confidence limit on the benchmark dose (BMDL 05 ) of 63 mg/kg bw/d. The plasma BE (9 μg Ba/L) was derived by regression analysis of the near-steady-state plasma concentrations associated with the administered doses in animals exposed to barium chloride dihydrate in drinking water for 2-years in a NTP study. Using a human urinary excretion fraction of 0.023, a BE for urinary barium (0.19 mg/L or 0.25 mg/g creatinine) was derived for US EPA's RfD. The median and the 95 th percentile barium urine concentrations of the general population in U.S. are below the BE determined in this study, indicating that the population exposure to inorganic barium is expected to be below the exposure guidance value of 0.2 mg/kg bw/d. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  12. Specific esophagogram to assess functional outcomes after Heller's myotomy and Dor's fundoplication for esophageal achalasia.

    PubMed

    Tsoukali, E; Gouvas, N; Tsiaoussis, J; Pechlivanides, G; Zervakis, N; Mantides, A; Xynos, E

    2011-09-01

    Esophageal emptying assessed at the 'timed barium' esophagogram correlates well with symptomatic outcomes after pneumatic dilation for esophageal achalasia, although 30% of patients with satisfactory outcome exhibit partial improvement in emptying. The aim of the study was to investigate any correlation of esophageal emptying to symptomatic response after laparoscopic Heller's myotomy and Dor's fundoplication. 'Bread and barium' (transit time of a barium opaque bread bolus) and 'timed barium' (height of esophageal barium column 5 minutes after ingestion of 200-250 mL of barium suspension) esophagogram was used to assess esophageal emptying in 73 patients with esophageal achalasia before 1 and 5 years (31 cases) after laparoscopic myotomy and anterior fundoplication. Symptoms assessment was based to a specific score. At 1-year follow-up, excellent and good symptomatic results were obtained in 95% of the cases. Esophageal maximum diameter, esophageal transit time, and esophageal barium column were significantly correlated to each other and to symptom score postoperatively (P < 0.001). Complete and partial (<90% and 50-90% postoperative reduction in barium column, respectively) emptying was seen in 55% and 31% of patients with excellent result. Patients with a pseudodiverticulum postoperatively had a more delayed esophageal emptying than those without. Symptomatic outcome and esophageal emptying did not deteriorate at 5-year follow-up. Esophageal emptying assessed by 'barium and bread' and 'timed barium' esophagogram correlated well with symptomatic outcome after laparoscopic myotomy for esophageal achalasia. Complete symptomatic relief does not necessarily reflect complete esophageal emptying. Outcomes do not deteriorate by time. Because of wide availability, esophagogram can be applied in follow-up of postmyotomy patients in conjunction with symptomatic evaluation. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  13. Comparison of bolus transit patterns identified by esophageal impedance to barium esophagram in patients with dysphagia.

    PubMed

    Cho, Y K; Choi, M-G; Oh, S N; Baik, C N; Park, J M; Lee, I S; Kim, S W; Choi, K Y; Chung, I-S

    2012-01-01

    Bolus transit through the esophagus has not been validated by videoesophagram in patients with dysphagia and changes in impedance with abnormal barium transit have not been described in those patients. The aim of this study was to compare esophageal impedance findings with barium esophagram measurements in patients with dysphagia. The consecutive patients with dysphagia underwent conventional multichannel esophageal impedance manometry, after which a barium videoesophagram was performed simultaneously with multichannel esophageal impedance manometry using a mean of three swallows of barium. Esophageal emptying patterns shown in the esophagogram were classified by the degree of intraesophageal stasis and presence of intraesophageal reflux. Bolus transit patterns in impedance were classified as complete and incomplete transit. Sixteen patients (M : F = 8 : 8, mean age, 47 years) were enrolled. Their manometric diagnosis were normal (n= 6), ineffective esophageal motility (n= 1), diffuse esophageal spasm (DES; n= 2), and achalasia (n= 7). Sixty-three swallows were analyzed. According to impedance analysis, 21/22 swallows with normal barium emptying showed complete transit (96%) and 31/32 swallows with severe stasis showed incomplete transit (97%). Nine swallows with mild stasis showed either complete or incomplete transit patterns in impedance. Swallows with mild barium stasis and complete transit in impedance were observed in patients who had received treatment (two patients with achalasia with history of esophageal balloonplasty and a patient with DES after nifedipine administration). Impedance reflected severe stasis with retrograde barium movement and described typical bolus transit patterns in patients with achalasia and DES. In conclusion, impedance-barium esophagram concordance is high for swallows with normal esophageal emptying and for severe barium stasis in patients with dysphagia. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  14. Evaluation of barium hydroxide treatment efficacy on a dolomitic marble.

    PubMed

    Toniolo, L; Colombo, C; Realini, M; Peraio, A; Positano, M

    2001-01-01

    The Arch of Peace, by Luigi Cagnola, is one of the most famous neoclassical monuments in Milan. It has been subjected to conservative intervention in 1998. In the present paper the efficacy of the consolidation by means of barium hydroxide has been evaluated. The stone material showed severe degradation phenomena as: erosion, pulverisation, exfoliation. The analytical data acquired through X-ray diffraction (XRD), infrared spectrophotometry (FTIR) and scanning electron microscopy (SEM-EDX), allowed to compare the conditions of stone before and after the treatment with barium hydroxide. The presence of barium has been put in evidence mainly on the surface as barium sulphate, whereas barium is only sporadically present within the thickness of the decayed material. The treatment was judged not satisfying and its inefficacy is, most probably, due to a not suitable cleaning procedure carried out before the consolidation.

  15. Barium promotes anchorage-independent growth and invasion of human HaCaT keratinocytes via activation of c-SRC kinase.

    PubMed

    Thang, Nguyen Dinh; Yajima, Ichiro; Kumasaka, Mayuko Y; Ohnuma, Shoko; Yanagishita, Takeshi; Hayashi, Rumiko; Shekhar, Hossain U; Watanabe, Daisuke; Kato, Masashi

    2011-01-01

    Explosive increases in skin cancers have been reported in more than 36 million patients with arsenicosis caused by drinking arsenic-polluted well water. This study and previous studies showed high levels of barium as well as arsenic in the well water. However, there have been no reports showing a correlation between barium and cancer. In this study, we examined whether barium (BaCl(2)) may independently have cancer-related effects on human precancerous keratinocytes (HaCaT). Barium (5-50 µM) biologically promoted anchorage-independent growth and invasion of HaCaT cells in vitro. Barium (5 µM) biochemically enhanced activities of c-SRC, FAK, ERK and MT1-MMP molecules, which regulate anchorage-independent growth and/or invasion. A SRC kinase specific inhibitor, protein phosphatase 2 (PP2), blocked barium-mediated promotion of anchorage-independent growth and invasion with decreased c-SRC kinase activity. Barium (2.5-5 µM) also promoted anchorage-independent growth and invasion of fibroblasts (NIH3T3) and immortalized nontumorigenic melanocytes (melan-a), but not transformed cutaneous squamous cell carcinoma (HSC5 and A431) and malignant melanoma (Mel-ret) cells, with activation of c-SRC kinase. Taken together, our biological and biochemical findings newly suggest that the levels of barium shown in drinking well water independently has the cancer-promoting effects on precancerous keratinocytes, fibroblast and melanocytes in vitro.

  16. Lack of effect of drinking water barium on cardiovascular risk factors.

    PubMed Central

    Wones, R G; Stadler, B L; Frohman, L A

    1990-01-01

    Higher cardiovascular mortality has been associated in a single epidemiological study with higher levels of barium in drinking water. The purpose of this study was to determine whether drinking water barium at levels found in some U.S. communities alters the known risk factors for cardiovascular disease. Eleven healthy men completed a 10-week dose-response protocol in which diet was controlled (600 mg cholesterol; 40% fat, 40% carbohydrate, 20% protein; sodium and potassium controlled at the subject's pre-protocol estimated intake). Other aspects of the subjects' lifestyles known to affect cardiac risk factors were controlled, and the barium content (as barium chloride) of the drinking water (1.5 L/day) was varied from 0 (first 2 weeks), to 5 ppm (next 4 weeks), to 10 ppm (last 4 weeks). Multiple blood and urine samples, morning and evening blood pressure measurements, and 48-hr electrocardiographic monitoring were performed at each dose of barium. There were no changes in morning or evening systolic or diastolic blood pressures, plasma cholesterol or lipoprotein or apolipoprotein levels, serum potassium or glucose levels, or urine catecholamine levels. There were no arrhythmias related to barium exposure detected on continuous electrocardiographic monitoring. A trend was seen toward increased total serum calcium levels with exposure to barium, which was of borderline statistical significance and of doubtful clinical significance. In summary, drinking water barium at levels of 5 and 10 ppm did not appear to affect any of the known modifiable cardiovascular risk factors. PMID:2384067

  17. Barium Promotes Anchorage-Independent Growth and Invasion of Human HaCaT Keratinocytes via Activation of c-SRC Kinase

    PubMed Central

    Thang, Nguyen Dinh; Yajima, Ichiro; Kumasaka, Mayuko Y.; Ohnuma, Shoko; Yanagishita, Takeshi; Hayashi, Rumiko; Shekhar, Hossain U.; Watanabe, Daisuke; Kato, Masashi

    2011-01-01

    Explosive increases in skin cancers have been reported in more than 36 million patients with arsenicosis caused by drinking arsenic-polluted well water. This study and previous studies showed high levels of barium as well as arsenic in the well water. However, there have been no reports showing a correlation between barium and cancer. In this study, we examined whether barium (BaCl2) may independently have cancer-related effects on human precancerous keratinocytes (HaCaT). Barium (5–50 µM) biologically promoted anchorage-independent growth and invasion of HaCaT cells in vitro. Barium (5 µM) biochemically enhanced activities of c-SRC, FAK, ERK and MT1-MMP molecules, which regulate anchorage-independent growth and/or invasion. A SRC kinase specific inhibitor, protein phosphatase 2 (PP2), blocked barium-mediated promotion of anchorage-independent growth and invasion with decreased c-SRC kinase activity. Barium (2.5–5 µM) also promoted anchorage-independent growth and invasion of fibroblasts (NIH3T3) and immortalized nontumorigenic melanocytes (melan-a), but not transformed cutaneous squamous cell carcinoma (HSC5 and A431) and malignant melanoma (Mel-ret) cells, with activation of c-SRC kinase. Taken together, our biological and biochemical findings newly suggest that the levels of barium shown in drinking well water independently has the cancer-promoting effects on precancerous keratinocytes, fibroblast and melanocytes in vitro. PMID:22022425

  18. Enhanced output-performance of piezoelectric poly(vinylidene fluoride trifluoroethylene) fibers-based nanogenerator with interdigital electrodes and well-ordered cylindrical cavities

    NASA Astrophysics Data System (ADS)

    Gui, Jinzheng; Zhu, Yezi; Zhang, Lingling; Shu, Xi; Liu, Wei; Guo, Shishang; Zhao, Xingzhong

    2018-02-01

    A piezoelectric nanogenerator based on poly(vinylidene fluoride trifluoroethylene) [P(VDF-TrFE)] nanofibers with an Au interdigital electrode (IDT)/P(VDF-TrFE) nanofiber film/well-ordered cylindrical cavity structure was prepared by combining Au IDTs with a rotary collector to obtain highly aligned P(VDF-TrFE) nanofiber arrays. The Au IDTs work not only as parallel electrodes to collect P(VDF-TrFE) nanofibers during electrospinning but also as charge-collecting electrodes in the nanogenerator. The well-ordered cylindrical cavities improve output performance by enhancing the deformation of P(VDF-TrFE) nanofiber films when subjected to external force. The nanogenerator performs well; as an example of application, we demonstrate energy harvesting from human walking, with a peak output voltage of 5 V and a peak short-circuit current of 1.2 μA. Such a device could have practical applications in wearable, self-powered devices.

  19. The problem of the barium stars

    NASA Technical Reports Server (NTRS)

    Bohm-Vitense, E.; Nemec, J.; Proffitt, C.

    1984-01-01

    Ultraviolet observations of barium stars and other cool stars with peculiar element abundances are reported. Those observations attempted to find hot white dwarf companions. Among six real barium stars studied, only Zeta Cap was found to have a white dwarf companion. Among seven mild, or marginal, barium stars studied, at least three were found to have hot subluminous companions. It is likely that all of them have white dwarf companions.

  20. Fabrication and characterization of cerium-doped barium titanate inverse opal by sol-gel method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin Yi; Zhu Yihua; Yang Xiaoling

    Cerium-doped barium titanate inverted opal was synthesized from barium acetate contained cerous acetate and tetrabutyl titanate in the interstitial spaces of a polystyrene (PS) opal. This procedure involves infiltration of precursors into the interstices of the PS opal template followed by hydrolytic polycondensation of the precursors to amorphous barium titanate and removal of the PS opal by calcination. The morphologies of opal and inverse opal were characterized by scanning electron microscope (SEM). The pores were characterized by mercury intrusion porosimetry (MIP). X-ray photoelectron spectroscopy (XPS) investigation showed the doping structure of cerium, barium and titanium. And powder X-ray diffraction allowsmore » one to observe the influence of doping degree on the grain size. The lattice parameters, crystal size and lattice strain were calculated by the Rietveld refinement method. The synthesis of cerium-doped barium titanate inverted opals provides an opportunity to electrically and optically engineer the photonic band structure and the possibility of developing tunable three-dimensional photonic crystal devices. - Graphical abstract: Cerium-doped barium titanate inverted opal was synthesized from barium acetate acid contained cerous acetate and tetrabutyl titanate in the interstitial spaces of a PS opal, which involves infiltration of precursors into the interstices of the PS opal template and removal of the PS opal by calcination.« less

  1. Creating unstable velocity-space distributions with barium injections

    NASA Technical Reports Server (NTRS)

    Pongratz, M. B.

    1983-01-01

    Ion velocity-space distributions resulting from barium injections from orbiting spacecraft and shaped charges are discussed. Active experiments confirm that anomalous ionization processes may operate, but photoionization accounts for the production of the bulk of the barium ions. Pitch-angle diffusion and/or velocity-space diffusion may occur, but observations of barium ions moving upwards against gravity suggests that the ions retain a significant enough fraction of their initial perpendicular velocity to provide a mirror force. The barium ion plasmas should have a range of Alfven Mach numbers and plasma betas. Because the initial conditions can be predicted these active experiments should permit testing plasma instability hypotheses.

  2. Self-Positioned Nanosized Mask for Transparent and Flexible Ferroelectric Polymer Nanodiodes Array.

    PubMed

    Hyun, Seung; Kwon, Owoong; Choi, Chungryong; Vincent Joseph, Kanniyambatti L; Kim, Yunseok; Kim, Jin Kon

    2016-10-12

    High density arrays of ferroelectric polymer nanodiodes have gained strong attention for next-generation transparent and flexible nonvolatile resistive memory. Here, we introduce a facile and innovative method to fabricate ferroelectric polymer nanodiode array on an ITO-coated poly(ethylene terephthalate) (PET) substrate by using block copolymer self-assembly and oxygen plasma etching. First, polystyrene-block-poly(2-vinylpyridine) copolymer (PS-b-P2VP) micelles were spin-coated on poly(vinylidene fluoride-ran-trifluoroethylene) copolymer (P(VDF-TrFE)) film/ITO-coated PET substrate. After the sample was immersed in a gold precursor (HAuCl 4 ) containing solution, which strongly coordinates with nitrogen group in P2VP, oxygen plasma etching was performed. During the plasma etching, coordinated gold precursors became gold nanoparticles (GNPs), which successfully acted as self-positioned etching mask to fabricate a high density array of P(VDF-TrFE)) nanoislands with GNP at the top. Each nanoisland shows clearly individual diode property, as confirmed by current-voltage (I-V) curve. Furthermore, due to the transparent and flexible nature of P(VDF-TrFE)) nanoisland as well as the substrate, the P(VDF-TrFE) nanodiode array was highly tranparent, and the diode property was maintained even after a large number of bendings (for instance, 1000 times). The array could be used as the next-generation tranparent and flexible nonvolatile memory device.

  3. Transparent, Conductive Coatings Developed for Arc-Proof Solar Arrays

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Transparent, conductive thin-film coatings have many potential applications where a surface must be able to dissipate electrical charges without sacrificing its optical properties. Such applications include automotive and aircraft windows, heat mirrors, optoelectronic devices, gas sensors, and solar cell array surfaces for space applications. Many spacecraft missions require that solar cell array surfaces dissipate charges in order to avoid damage such as electronic upsets, formation of pinholes in the protective coatings on solar array blankets, and contamination due to deposition of sputtered products. In tests at the NASA Lewis Research Center, mixed thin-films of sputter-deposited indium tin oxide (ITO) and magnesium fluoride (MgF2) that could be tailored to the desired sheet resistivity, showed transmittance values of greater than 90 percent. The samples evaluated were composed of mixed, thin-film ITO/MgF2 coatings, with a nominal thickness of 650 angstroms, deposited onto glass substrates. Preliminary results indicated that these coatings were durable to vacuum ultraviolet radiation and atomic oxygen. These coatings show promise for use on solar array surfaces in polar low-Earth-orbit environments, where a sheet resistivity of less than 10(exp 8)/square is required, and in geosynchronous orbit environments, where a resistivity of less than 10(exp 9)/square is required.

  4. 49 CFR 173.182 - Barium azide-50 percent or more water wet.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Barium azide-50 percent or more water wet. 173.182... Class 1 and Class 7 § 173.182 Barium azide—50 percent or more water wet. Barium azide—50 percent or more water wet, must be packed in wooden boxes (4C1, 4C2, 4D, or 4F) or fiber drums (1G) with inner glass...

  5. 49 CFR 173.182 - Barium azide-50 percent or more water wet.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Barium azide-50 percent or more water wet. 173.182... Class 1 and Class 7 § 173.182 Barium azide—50 percent or more water wet. Barium azide—50 percent or more water wet, must be packed in wooden boxes (4C1, 4C2, 4D, or 4F) or fiber drums (1G) with inner glass...

  6. BARIUM AND STRONTIUM CONCENTRATIONS IN EYE TISSUE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sowden, E.; Pirie, A.

    1958-12-01

    The stroniium and barium conient of the differeni parts of the eye has been estimated by the method of activation analysis in cattie, rabbit, and man. The pigmented parts of the eye coatain more stroatium and barium than the other parts, and barium in particular is concentrated in the choroid of the cow. These results are discussed in relation to the presence of high concentrations of zinc in the choroidal tapetum lucidum of other animals. (auth)

  7. [Value of preoperative barium contrast examination for the diagnosis and operative planning in gastric cancer].

    PubMed

    Wang, Chang-jian; Zhao, Guang-fa; Li, Qing-guo; Chen, Jing-gui; Zhu, Kai; Shi, Ying-qiang; Fu, Hong

    2010-04-01

    To investigate the value of preoperative barium contrast examination for the diagnosis and operative planning in gastric cancer. Clinical data of 229 gastric cancer patients were analyzed retrospectively. Lesions were divided into three parts: the cardiac, the body, and the antrum. The diagnostic accuracy of localization and the extent of tumor between gastroscopy alone and gastroscopy plus barium contrast were compared with the results of surgical findings. The diagnostic accuracy of localization and the extent of tumor for gastroscopy in the cardiac, the body and the antrum cancers were 100% and 78.4%, 94.6% and 86.5%, 98.1% and 84.6%, respectively, while for gastroscopy plus barium contrast were 100% and 84.8%, 100% and 91.9%, 99.0% and 90.4%, respectively. The diagnostic accuracy of both the localization and the extent of tumor were not significantly different between gastroscopy alone and gastroscopy plus barium contrast (P>0.05). Diagnostic accuracy of the length of esophagus infiltrated by cardiac cancer in gastroscopy was 60.6%, while in gastroscopy plus barium contrast was 90.9%, which was significantly different (P<0.05). Gastroscopy plus barium contrast was more accurate in predicting the possibility of thoracotomy in cardiac cancer infiltrating the lower esophagus. It is necessary to perform preoperative barium contrast examination in cardiac cancer patients, so as to identify whether the lower esophagus is infiltrated and to measure the length of lesion, which can provide evidences for making a decision of thoracotomy. For gastric body and antrum cancer, there is no indication for barium contrast examination if gastroscopy findings are satisfied.

  8. Sponge-associated bacteria mineralize arsenic and barium on intracellular vesicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keren, Ray; Mayzel, Boaz; Lavy, Adi

    Arsenic and barium are ubiquitous environmental toxins that accumulate in higher trophic-level organisms. Whereas metazoans have detoxifying organs to cope with toxic metals, sponges lack organs but harbour a symbiotic microbiome performing various functions. Here we examine the potential roles of microorganisms in arsenic and barium cycles in the sponge Theonella swinhoei, known to accumulate high levels of these metals. We show that a single sponge symbiotic bacterium, Entotheonella sp., constitutes the arsenic- and barium-accumulating entity within the host. These bacteria mineralize both arsenic and barium on intracellular vesicles. Our results indicate that Entotheonella sp. may act as a detoxifyingmore » organ for its host.« less

  9. Sponge-associated bacteria mineralize arsenic and barium on intracellular vesicles

    DOE PAGES

    Keren, Ray; Mayzel, Boaz; Lavy, Adi; ...

    2017-02-24

    Arsenic and barium are ubiquitous environmental toxins that accumulate in higher trophic-level organisms. Whereas metazoans have detoxifying organs to cope with toxic metals, sponges lack organs but harbour a symbiotic microbiome performing various functions. Here we examine the potential roles of microorganisms in arsenic and barium cycles in the sponge Theonella swinhoei, known to accumulate high levels of these metals. We show that a single sponge symbiotic bacterium, Entotheonella sp., constitutes the arsenic- and barium-accumulating entity within the host. These bacteria mineralize both arsenic and barium on intracellular vesicles. Our results indicate that Entotheonella sp. may act as a detoxifyingmore » organ for its host.« less

  10. Diagnostic Validity of High-Density Barium Sulfate in Gastric Cancer Screening: Follow-up of Screenees by Record Linkage with the Osaka Cancer Registry

    PubMed Central

    Yamamoto, Kenyu; Yamazaki, Hideo; Kuroda, Chikazumi; Kubo, Tsugio; Oshima, Akira; Katsuda, Toshizo; Kuwano, Tadao; Takeda, Yoshihiro

    2010-01-01

    Background The use of high-density barium sulfate was recommended by the Japan Society of Gastroenterological Cancer Screening (JSGCS) in 2004. We evaluated the diagnostic validity of gastric cancer screening that used high-density barium sulfate. Methods The study subjects were 171 833 residents of Osaka, Japan who underwent gastric cancer screening tests at the Osaka Cancer Prevention and Detection Center during the period from 1 January 2000 through 31 December 2001. Screening was conducted using either high-density barium sulfate (n = 48 336) or moderate-density barium sulfate (n = 123 497). The subjects were followed up and their medical records were linked to those of the Osaka Cancer Registry through 31 December 2002. The results of follow-up during 1 year were defined as the gold standard, and test performance values were calculated. Results The sensitivity and specificity of the screening test using moderate-density barium sulfate were 92.3% and 91.0%, respectively, while the sensitivity and specificity of the high-density barium test were 91.8% and 91.4%, respectively. The results of area under receiver-operating-characteristic (ROC) curve analysis revealed no significant difference between the 2 screening tests. Conclusions Screening tests using high- and moderate-density barium sulfate had similar validity, as determined by sensitivity, specificity, and ROC curve analysis. PMID:20551581

  11. Three-dimensional, two-species magnetohydrodynamic studies of the early time behaviors of the Combined Release and Radiation Effects Satellite G2 barium release

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Lianghai, E-mail: xielh@nssc.ac.cn; Li, Lei; Wang, Jingdong

    2014-04-15

    We present a three-dimensional, two-species (Ba{sup +} and H{sup +}) MHD model to study the early time behaviors of a barium release at about 1 R{sub E} like Combined Release and Radiation Effects Satellite G2, with emphasis placed on the three-dimensional evolution of the barium cloud and its effects on the ambient plasma environment. We find that the perturbations caused by the cloud are the combined results of the initial injection, the radial expansion, and the diamagnetic effect and propagate as fast MHD waves in the magnetosphere. In return, the transverse expansion and the cross-B motion of barium ions aremore » constrained by the magnetic force, which lead to a field-aligned striation of ions and the decoupling of these ions from the neutrals. Our simulation shows the formation and collapse of the diamagnetic cavity in the barium cloud. The estimated time scale for the cavity evolution might be much shorter if photoionization time scale and field aligned expansion of barium ions are considered. In addition, our two species MHD simulation also finds the snowplow effect resulting from the momentum coupling between barium ions and background H{sup +}, which creates density hole and bumps in the background H{sup +} when barium ions expanding along the magnetic field lines.« less

  12. Study on improving the heat storage property of Ba(OH)2·8H2O with paraffin

    NASA Astrophysics Data System (ADS)

    Cui, Kaixuan; Liu, Liqiang; Sun, Mingjie

    2017-12-01

    Barium hydroxide octahydrate is the crystalline hydration salt with the highest latent heat density within the phase change temperature interval of 0-120 °C and it has a broad application prospect as a phase-change material (PCM). Firstly, red copper test tube was used for the melting—solidification heat cycle experiment in this paper, which was verified by the corrosion experiment of barium hydroxide solution. After the thermogravimetric analysis, it is found that paraffin can effectively reduce the evaporation escape of barium hydroxide octahydrate crystal water within 100 °C. Repeated heat cycle experiments indicated that the paraffin with larger coverage mass fraction can reduce the inhibiting effect of barium hydroxide octahydrate crystal water more obviously. X-ray diffraction analysis indicated that the phase composition of the barium hydroxide octahydrate sample covered with 50 wt% paraffin nearly had no change, while the sample not covered with paraffin has the weight loss ratio of 34.67% and reacted with CO2 in the air, generating BaCO3. In summary, paraffin can not only inhibit the evaporation of crystal water, but also effectively isolate the air to prevent barium hydroxide octahydrate from denaturation. This greatly improved the practicability of barium hydroxide octahydrate as a PCM, laying a good foundation for the further application of barium hydroxide octahydrate.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Jing; Chongqing University of Science and Technology, Chongqing 401331; Hu, Chenguo, E-mail: hucg@cqu.edu.cn

    Graphical abstract: The flower-shaped barium vanadate was obtained for the first time. The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. Research highlights: {yields} In the paper, the flower-shaped barium vanadate were obtained for the first time. The CHM method used here is new and simple for preparation of barium vanadate. {yields} The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. The strong bluish-green emission was observed. {yields} The ferromagnetic behavior of the barium vanadate nanoflowers was found with saturation magnetization of about 83.50 x 10{sup -3} emu/g,more » coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10{sup -3} emu/g. {yields} The mechanisms of PL and magnetic property of barium vanadate nanoflowers have been discussed. -- Abstract: The flower-shaped barium vanadate has been obtained by the composite hydroxide mediated (CHM) method from V{sub 2}O{sub 5} and BaCl{sub 2} at 200 {sup o}C for 13 h. XRD and XPS spectrum of the as-synthesized sample indicate it is hexagonal Ba{sub 3}V{sub 2}O{sub 8} with small amount of Ba{sub 3}VO{sub 4.8} coexistence. Scan electron microscope and transmission electron microscope display that the flower-shaped crystals are composed of nanosheets with thickness of {approx}20 nm. The UV-visible spectrum shows that the barium vanadate sample has two optical gaps (3.85 eV and 3.12 eV). Photoluminescence spectrum of the barium vanadate flowers exhibits a visible light emission centered at 492 and 525 nm which might be attributed to VO{sub 4} tetrahedron with T{sub d} symmetry in Ba{sub 3}V{sub 2}O{sub 8}. The ferromagnetic behavior of the barium vanadate nanoflowers has been found with saturation magnetization of about 83.50 x 10{sup -3} emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10{sup -3} emu/g, which is mainly due to the presence of a non-orthovanadate phase with spin S = 1/2.« less

  14. 21 CFR 175.105 - Adhesives.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-isobutyronitrile Balata rubber Barium acetate Barium peroxide Barium sulfate Bentonite Benzene (benzol) 1,4... Chromium potassium sulfate Cobaltous acetate Coconut fatty acid amine salt of tetrachlorophenol For use as... sulfonamide Fats and oils derived from animal or vegetable sources, and the hydrogenated, sulfated, or...

  15. 21 CFR 175.105 - Adhesives.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...-isobutyronitrile Balata rubber Barium acetate Barium peroxide Barium sulfate Bentonite Benzene (benzol) 1,4... Chromium potassium sulfate Cobaltous acetate Coconut fatty acid amine salt of tetrachlorophenol For use as... sulfonamide Fats and oils derived from animal or vegetable sources, and the hydrogenated, sulfated, or...

  16. Freeze cast porous barium titanate for enhanced piezoelectric energy harvesting

    NASA Astrophysics Data System (ADS)

    Roscow, J. I.; Zhang, Y.; Kraśny, M. J.; Lewis, R. W. C.; Taylor, J.; Bowen, C. R.

    2018-06-01

    Energy harvesting is an important developing technology for a new generation of self-powered sensor networks. This paper demonstrates the significant improvement in the piezoelectric energy harvesting performance of barium titanate by forming highly aligned porosity using freeze casting. Firstly, a finite element model demonstrating the effect of pore morphology and angle with respect to poling field on the poling behaviour of porous ferroelectrics was developed. A second model was then developed to understand the influence of microstructure-property relationships on the poling behaviour of porous freeze cast ferroelectric materials and their resultant piezoelectric and energy harvesting properties. To compare with model predictions, porous barium titanate was fabricated using freeze casting to form highly aligned microstructures with excellent longitudinal piezoelectric strain coefficients, d 33. The freeze cast barium titanate with 45 vol.% porosity had a d 33  =  134.5 pC N‑1 compared to d 33  =  144.5 pC N‑1 for dense barium titanate. The d 33 coefficients of the freeze cast materials were also higher than materials with uniformly distributed spherical porosity due to improved poling of the aligned microstructures, as predicted by the models. Both model and experimental data indicated that introducing porosity provides a large reduction in the permittivity () of barium titanate, which leads to a substantial increase in energy harvesting figure of merit, , with a maximum of 3.79 pm2 N‑1 for barium titanate with 45 vol.% porosity, compared to only 1.40 pm2 N‑1 for dense barium titanate. Dense and porous barium titanate materials were then used to harvest energy from a mechanical excitation by rectification and storage of the piezoelectric charge on a capacitor. The porous barium titanate charged the capacitor to a voltage of 234 mV compared to 96 mV for the dense material, indicating a 2.4-fold increase that was similar to that predicted by the energy harvesting figures of merit.

  17. Understanding the Viscosity of Liquids used in Infant Dysphagia Management

    PubMed Central

    Frazier, Jackie; Chestnut, Amanda; Jackson, Arwen; Barbon, Carly E. A.; Steele, Catriona M.; Pickler, Laura

    2016-01-01

    When assessing swallowing in infants, it is critical to have confidence that the liquids presented during the swallow study closely replicate the viscosity of liquids in the infant's typical diet. However, we lack research on rheological properties of frequently used infant formulas or breastmilk, and various forms of barium contrast media used in swallow studies. The aim of the current study was to provide objective viscosity measurements for typical infant liquid diet options and barium contrast media. A TA-Instruments AR2000 Advanced Rheometer was used to measure the viscosity, five standard infant formulas, three barium products and two breastmilk samples. Additionally, this study measured the viscosity of infant formulas and breastmilk when mixed with powdered barium contrast in a 20% weight-to-volume (w/v) concentration. Study findings determined that standard infant formulas and the two breastmilk samples had low viscosities, at the lower end of the National Dysphagia Diet (NDD) thin liquid range. Two specialty formulas tested had much thicker viscosities, close to the NDD nectar-thick liquid range lower boundary. The study showed differences in viscosity between two 60% w/v barium products (Liquid E-Z-Paque® and E-Z-Paque® powder); the powdered product had a much lower viscosity, despite identical barium concentration. When E-Z-Paque® powdered barium was mixed in a 20% w/v concentration using water, standard infant formulas or breastmilk, the resulting viscosities were at the lower end of the NDD thin range, and only slightly thicker than the non-barium comparator liquids. When E-Z-Paque® powdered barium was mixed in a 20% w/v concentration with the two thicker specialty formulas (Enfamil AR 20kcal and 24 kcal), unexpected alterations in their original viscosity occurred. These findings highlight the clinical importance of objective measures of viscosity as well as objective data on how infant formulas or breastmilk may change in consistency when mixed with barium. PMID:27412005

  18. Understanding the Viscosity of Liquids used in Infant Dysphagia Management.

    PubMed

    Frazier, Jacqueline; Chestnut, Amanda H; Jackson, Arwen; Barbon, Carly E A; Steele, Catriona M; Pickler, Laura

    2016-10-01

    When assessing swallowing in infants, it is critical to have confidence that the liquids presented during the swallow study closely replicate the viscosity of liquids in the infant's typical diet. However, we lack research on rheological properties of frequently used infant formulas or breastmilk, and various forms of barium contrast media used in swallow studies. The aim of the current study was to provide objective viscosity measurements for typical infant liquid diet options and barium contrast media. A TA-Instruments AR2000 Advanced Rheometer was used to measure the viscosity of five standard infant formulas, three barium products, and two breastmilk samples. Additionally, this study measured the viscosity of infant formulas and breastmilk when mixed with powdered barium contrast in a 20 % weight-to-volume (w/v) concentration. The study findings determined that standard infant formulas and the two breastmilk samples had low viscosities, at the lower end of the National Dysphagia Diet (NDD) thin liquid range. Two specialty formulas tested had much thicker viscosities, close to the lower boundary of the NDD nectar-thick liquid range. The study showed differences in viscosity between 60 % w/v barium products (Liquid E-Z-Paque(®) and E-Z-Paque(®) powder); the powdered product had a much lower viscosity, despite identical barium concentration. When E-Z-Paque(®) powdered barium was mixed in a 20 % w/v concentration using water, standard infant formulas, or breastmilk, the resulting viscosities were at the lower end of the NDD thin range and only slightly thicker than the non-barium comparator liquids. When E-Z-Paque(®) powdered barium was mixed in a 20 % w/v concentration with the two thicker specialty formulas (Enfamil AR 20 and 24 kcal), unexpected alterations in their original viscosity occurred. These findings highlight the clinical importance of objective measures of viscosity as well as objective data on how infant formulas or breastmilk may change in consistency when mixed with barium.

  19. Fatal barium chloride poisoning: four cases report and literature review.

    PubMed

    Ananda, Sunnassee; Shaohua, Zhu; Liang, Liu

    2013-06-01

    Barium is an alkaline earth metal which has a variety of uses including in the manufacturing industry and in medicine. However, adverse health effects and fatalities occur due to absorption of soluble barium compounds, notably the chloride, nitrate, and hydroxide, which are toxic to humans. Although rare, accidental and suicidal modes of poisoning are sporadically reported in the literature.We describe 4 cases of poisoning due to barium chloride in China. In witnessed cases, severe gastrointestinal symptoms, hypokalemia leading to muscle weakness, cardiac arrhythmias, and respiratory failure were noted. Autopsy showed some nonspecific but common findings, such as subendocardial hemorrhage in the ventricles, visceral petechiae, and fatty changes in the liver. Interestingly, microscopic examination showed degenerative changes and amorphous, flocculent foamy materials in the renal tubules. Toxicology was relevant for barium in blood and tissues. Three of the cases were accidental and 1 homicidal in nature. A round-up of relevant literature on fatal barium compounds poisoning is also provided. Forensic pathologists should be aware of the clinical presentations of barium compound poisoning and especially look for any evidence of hypokalemia. Still, postmortem toxicological and histological studies are essential for an accurate identification of the cause of death.

  20. Uncertainty-enabled design of electromagnetic reflectors with integrated shape control

    NASA Astrophysics Data System (ADS)

    Haque, Samiul; Kindrat, Laszlo P.; Zhang, Li; Mikheev, Vikenty; Kim, Daewa; Liu, Sijing; Chung, Jooyeon; Kuian, Mykhailo; Massad, Jordan E.; Smith, Ralph C.

    2018-03-01

    We implemented a computationally efficient model for a corner-supported, thin, rectangular, orthotropic polyvinylidene fluoride (PVDF) laminate membrane, actuated by a two-dimensional array of segmented electrodes. The laminate can be used as shape-controlled electromagnetic reflector and the model estimates the reflector's shape given an array of control voltages. In this paper, we describe a model to determine the shape of the laminate for a given distribution of control voltages. Then, we investigate the surface shape error and its sensitivity to the model parameters. Subsequently, we analyze the simulated deflection of the actuated bimorph using a Zernike polynomial decomposition. Finally, we provide a probabilistic description of reflector performance using statistical methods to quantify uncertainty. We make design recommendations for nominal parameter values and their tolerances based on optimization under uncertainty using multiple methods.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kishimoto, S., E-mail: syunji.kishimoto@kek.jp; Haruki, R.; Mitsui, T.

    We developed a silicon avalanche photodiode (Si-APD) linear-array detector to be used for time-resolved X-ray scattering experiments using synchrotron X-rays. The Si-APD linear array consists of 64 pixels (pixel size: 100 × 200 μm{sup 2}) with a pixel pitch of 150 μm and a depletion depth of 10 μm. The multichannel scaler counted X-ray pulses over continuous 2046 time bins for every 0.5 ns and recorded a time spectrum at each pixel with a time resolution of 0.5 ns (FWHM) for 8.0 keV X-rays. Using the detector system, we were able to observe X-ray peaks clearly separated with 2 nsmore » interval in the multibunch-mode operation of the Photon Factory ring. The small-angle X-ray scattering for polyvinylidene fluoride film was also observed with the detector.« less

  2. Chemical modification of TiO2 nanotube arrays for label-free optical biosensing applications

    NASA Astrophysics Data System (ADS)

    Terracciano, Monica; Galstyan, Vardan; Rea, Ilaria; Casalino, Maurizio; De Stefano, Luca; Sbervegleri, Giorgio

    2017-10-01

    In this study, we have fabricated TiO2 nanotube arrays by the potentiostatic anodic oxidation of Ti foils in fluoride-containing electrolyte and explored them as versatile devices for biosensing applications. TiO2 nanotubes have been chemically modified in order to bind Protein A as a specific target analyte for the optical biosensing. The obtained structures have been characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, water contact angle, fluorescence microscopy, spectroscopic reflectometry and photoluminescence. Investigations show that the prepared TiO2 nanotubes, 2.5 μm long and 75 nm thick, can be easily and efficiently bio-modified, and the obtained structures are strongly photoluminescent, thus suitable for the label-free biosensing applications in the range of μM, due to their peculiar optical properties.

  3. Progress on CBET Platform at the Nike Laser

    NASA Astrophysics Data System (ADS)

    Weaver, J. L.; McKenty, P.; Oh, J.; Kehne, D.; Schmitt, A. J.; Obenschain, S.; Serlin, V.; Lehmberg, R.; Tsung, F.

    2015-11-01

    Cross-beam energy transport (CBET) studies are underway at the Nike krypton-fluoride (KrF) laser at NRL. This facility has unique characteristics that provide an excellent platform for CBET work - including short wavelength (248 nm), large bandwidth (1-3 THz), beam smoothing by induced spatial incoherence (ISI), and full aperture focal spot zooming. Nike's two beam arrays are widely separated (135° in azimuth) which facilitates CBET studies in a nearly opposing geometry, relevant to Polar Direct Drive implosions. Various target types are planned: planar slabs, cylindrical and spherical shells, and low-density targets. The solid targets will be used to examine gradient geometries and the latter will access larger volume, more uniform plasmas. The initial campaign is exploring changes observed by scattered light diagnostics for both beam arrays as the probe laser spectrum is modified. Work supported by DoE/NNSA.

  4. Tested Demonstrations.

    ERIC Educational Resources Information Center

    Gilbert, George L., Ed.

    1984-01-01

    Two demonstrations are described. The first shows the effect of polarity on solubility. The second is based on the unexpected formation of a precipitate of barium nitrate when barium carbonate or barium phosphate is treated with dilute nitric acid. List of materials needed and procedures used are included. (JN)

  5. Effect of variations in the redox potential of Gleysol on barium mobility and absorption in rice plants.

    PubMed

    Magalhães, Marcio Osvaldo Lima; Sobrinho, Nelson Moura Brasil do Amaral; Zonta, Everaldo; de Carvalho, Michel Miranda; Tolón-Becerra, Alfredo

    2012-09-01

    Two assays were designed to obtain information about the influence of redox potential variations on barium mobility and bioavailability in soil. One assay was undertaken in leaching columns, and the other was conducted in pots cultivated with rice (Oryza sativa) using soil samples collected from the surface of Gleysol in both assays. Three doses of barium (100,300 mg kg(-1) and 3000 mg kg(-1)-soil dry weight) and two redox potential values (oxidizing and reducing) were evaluated. During the incubation period, the redox potential (Eh) was monitored in columns and pots until values of -250 mV were reached. After the incubation period, geochemical partitioning was conducted on the barium using the European Communities Bureau of Reference (BCR) method. Rainfall of 200 mm d(-1) was simulated in the columns and in the planting of rice seedlings in the pots. The results of the geochemical partitioning demonstrated that the condition of reduction favors increased barium concentrations in the more labile chemical forms and decreased levels in the chemical forms related to oxides. The highest barium concentrations in leached extracts (3.36 mg L(-1)) were observed at the highest dose and condition of reduction at approximately five times above the drinking water standard. The high concentrations of barium in the soil did not affect plant dry matter production. The highest levels and accumulation of barium in roots, leaves, and grains of rice were found at the highest dose and condition of reduction. These results demonstrate that reduction leads to solubilization of barium sulfate, thereby favoring greater mobility and bioavailability of this element. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Severe acute cholangitis after endoscopic sphincterotomy induced by barium examination: A case report

    PubMed Central

    Zhang, Zhen-Hai; Wu, Ya-Guang; Qin, Cheng-Kun; Su, Zhong-Xue; Xu, Jian; Xian, Guo-Zhe; Wu, Shuo-Dong

    2012-01-01

    Endoscopic sphincterotomy (EST) is considered as a possible etiological factor for severe cholangitis. We herein report a case of severe cholangitis after endoscopic sphincterotomy induced by barium examination. An adult male patient presented with epigastric pain was diagnosed as having choledocholithiasis by ultrasonography. EST was performed and the stone was completely cleaned. Barium examination was done 3 d after EST and severe cholangitis appeared 4 h later. The patient was recovered after treated with tienam for 4 d. Barium examination may induce severe cholangitis in patients after EST, although rare, barium examination should be chosen cautiously. Cautions should be also used when EST is performed in patients younger than 50 years to avoid the damage to the sphincter of Oddi. PMID:23112564

  7. Severe acute cholangitis after endoscopic sphincterotomy induced by barium examination: A case report.

    PubMed

    Zhang, Zhen-Hai; Wu, Ya-Guang; Qin, Cheng-Kun; Su, Zhong-Xue; Xu, Jian; Xian, Guo-Zhe; Wu, Shuo-Dong

    2012-10-21

    Endoscopic sphincterotomy (EST) is considered as a possible etiological factor for severe cholangitis. We herein report a case of severe cholangitis after endoscopic sphincterotomy induced by barium examination. An adult male patient presented with epigastric pain was diagnosed as having choledocholithiasis by ultrasonography. EST was performed and the stone was completely cleaned. Barium examination was done 3 d after EST and severe cholangitis appeared 4 h later. The patient was recovered after treated with tienam for 4 d. Barium examination may induce severe cholangitis in patients after EST, although rare, barium examination should be chosen cautiously. Cautions should be also used when EST is performed in patients younger than 50 years to avoid the damage to the sphincter of Oddi.

  8. Dye-sensitized solar cell with energy storage function through PVDF/ZnO nanocomposite counter electrode.

    PubMed

    Zhang, Xi; Huang, Xuezhen; Li, Chensha; Jiang, Hongrui

    2013-08-14

    Dye-sensitized solar cells with an energy storage function are demonstrated by modifying its counter electrode with a poly (vinylidene fluoride)/ZnO nanowire array composite. This simplex device could still function as an ordinary solar cell with a steady photocurrent output even after being fully charged. An energy storage density of 2.14 C g(-1) is achieved, while simultaneously a 3.70% photo-to-electric conversion efficiency is maintained. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. High pressure–low temperature phase diagram of barium: Simplicity versus complexity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desgreniers, Serge; Tse, John S., E-mail: John.Tse@usask.ca; State Key Laboratory of Superhard Materials, Jilin University, 130012 Changchun

    2015-11-30

    Barium holds a distinctive position among all elements studied upon densification. Indeed, it was the first example shown to violate the long-standing notion that high compression of simple metals should preserve or yield close-packed structures. From modest pressure conditions at room temperature, barium transforms at higher pressures from its simple structures to the extraordinarily complex atomic arrangements of the incommensurate and self-hosting Ba-IV phases. By a detailed mapping of the pressure/temperature structures of barium, we demonstrate the existence of another crystalline arrangement of barium, Ba-VI, at low temperature and high pressure. The simple structure of Ba-VI is unlike that ofmore » complex Ba-IV, the phase encountered in a similar pressure range at room temperature. First-principles calculations predict Ba-VI to be stable at high pressure and superconductive. The results illustrate the complexity of the low temperature-high pressure phase diagram of barium and the significant effect of temperature on structural phase transformations.« less

  10. Synthesis and characterization of barium hexaferrite with manganese (Mn) doping material as anti-radar

    NASA Astrophysics Data System (ADS)

    Susilawati, Doyan, Aris; Khalilurrahman

    2017-01-01

    Have been successfully synthesized barium powder doping Manganese hexaferrite with the expected potential as anti-radar material. Synthesis was done by using the co-precipitation method, the variation of the variable x concentrations used were 0; 0.2; 0.4; and 0.6 and calcined at temperatures of 400, 600 and 800°C. Characterization powders of hexaferrite have used XRD (X-Ray Diffraction), SEM (Scanning Electron Microscopy), TEM (Transmission Electron Microscopy), LCR (inductance, capacitance, and resistance) meter, and VSM (Vibrating Sample Magnetometer). The higher the concentration and temperature of calcinations given affect the color of the powder. The test results using XRD indicates that it has formed barium hexaferrite phase with a hexagonal crystal structure. Tests using SEM showed that all the constituent elements barium powder hexaferrite by doping Manganese powders have been spread evenly. XRD test results were confirmed by a test using a TEM showing the crystal structure and the powder was sized nano particles. The results from the LCR meter showed that the barium powder hexaferrite by doping Manganese that has been synthesized classified in semiconductor materials. The result from VSM showed that the value of coercivity magnetic powder doped barium hexaferrite Manganese is smaller when compared with barium hexaferrite without doping and belong to the soft magnetic. Based on the results of the synthesis and characterization, we can conclude that the barium powder heksaferrite by doping Manganese potential as a material anti-radar.

  11. 40 CFR 721.10011 - Barium calcium manganese strontium oxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... manganese strontium oxide (PMN P-00-1124; CAS No. 359427-90-0) is subject to reporting under this section... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Barium calcium manganese strontium... Specific Chemical Substances § 721.10011 Barium calcium manganese strontium oxide. (a) Chemical substance...

  12. 40 CFR 721.10011 - Barium calcium manganese strontium oxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... manganese strontium oxide (PMN P-00-1124; CAS No. 359427-90-0) is subject to reporting under this section... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Barium calcium manganese strontium... Specific Chemical Substances § 721.10011 Barium calcium manganese strontium oxide. (a) Chemical substance...

  13. 40 CFR 721.10011 - Barium calcium manganese strontium oxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... manganese strontium oxide (PMN P-00-1124; CAS No. 359427-90-0) is subject to reporting under this section... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Barium calcium manganese strontium... Specific Chemical Substances § 721.10011 Barium calcium manganese strontium oxide. (a) Chemical substance...

  14. Upper gastrointestinal barium evaluation of duodenal pathology: A pictorial review

    PubMed Central

    Gupta, Pankaj; Debi, Uma; Sinha, Saroj Kant; Prasad, Kaushal Kishor

    2014-01-01

    Like other parts of the gastrointestinal tract (GIT), duodenum is subject to a variety of lesions both congenital and acquired. However, unlike other parts of the GIT viz. esophagus, rest of the small intestine and large intestine, barium evaluation of duodenal lesions is technically more challenging and hence not frequently reported. With significant advances in computed tomography technology, a thorough evaluation including intraluminal, mural and extramural is feasible in a single non-invasive examination. Notwithstanding, barium evaluation still remains the initial and sometimes the only imaging study in several parts of the world. Hence, a thorough acquaintance with the morphology of various duodenal lesions on upper gastrointestinal barium examination is essential in guiding further evaluation. We reviewed our experience with various common and uncommon barium findings in duodenal abnormalities. PMID:25170399

  15. Numberical simulation of the effects of radially injected barium plasma in the ionosphere

    NASA Technical Reports Server (NTRS)

    Swift, D. W.

    1985-01-01

    The morphology of the ion cloud in the radial shaped charge barium injection was studied. The shape of the ion cloud that remains after the explosive products and neutral barium clears away was examined. The ion cloud which has the configuration of a rimless wagon wheel is shown. The major features are the 2.5 km radius black hole in the center of the cloud, the surrounding ring of barium ion and the spokes of barium ionization radiating away from the center. The cloud shows no evolution after it emerges from the neutral debris and it is concluded that it is formed within 5 seconds of the event. A numerical model is used to calculate the motion of ions and electrons subject to the electrostatic and lorenz forces.

  16. A proposed physical model for the impregnated tungsten cathode based on Auger surface studies of the Ba-O-W system

    NASA Technical Reports Server (NTRS)

    Forman, R.

    1979-01-01

    Auger spectra and work function measurements are used to study the surface reactions between tungsten surface and adsorbed layers of barium, and barium and oxygen. The barium on an impregnated tungsten cathod seems to be an intermediate state, probably a coadsorbed barium-oxygen layer on tungsten. A slightly revised version of the previously suggested (1976) impregnated tungsten cathode model is proposed. This revised model assumes that the cathode surface during life has an adsorbed surface layer of a monolayer or less of both barium and oxygen on the surface. At end of life, steep drop in electron emission and resultant cathode failure occur. Recent NASA life test results on TWT type tubes are reported and explained by the proposed model.

  17. Comparison of Calcium and Barium Microcapsules as Scaffolds in the Development of Artificial Dermal Papillae.

    PubMed

    Liu, Yang; Lin, Changmin; Zeng, Yang; Li, Haihong; Cai, Bozhi; Huang, Keng; Yuan, Yanping; Li, Yu

    2016-01-01

    This study aimed to develop and evaluate barium and calcium microcapsules as candidates for scaffolding in artificial dermal papilla. Dermal papilla cells (DPCs) were isolated and cultured by one-step collagenase treatment. The DPC-Ba and DPC-Ca microcapsules were prepared by using a specially designed, high-voltage, electric-field droplet generator. Selected microcapsules were assessed for long-term inductive properties with xenotransplantation into Sprague-Dawley rat ears. Both barium and calcium microcapsules maintained xenogenic dermal papilla cells in an immunoisolated environment and induced the formation of hair follicle structures. Calcium microcapsules showed better biocompatibility, permeability, and cell viability in comparison with barium microcapsules. Before 18 weeks, calcium microcapsules gathered together, with no substantial immune response. After 32 weeks, some microcapsules were near inflammatory cells and wrapped with fiber. A few large hair follicles were found. Control samples showed no marked changes at the implantation site. Barium microcapsules were superior to calcium microcapsules in structural and mechanical stability. The cells encapsulated in hydrogel barium microcapsules exhibited higher short-term viability. This study established a model to culture DPCs in 3D culture conditions. Barium microcapsules may be useful in short-term transplantation study. Calcium microcapsules may provide an effective scaffold for the development of artificial dermal papilla.

  18. Tunable ferromagnetic resonance in La-Co substituted barium hexaferrites at millimeter wave frequencies

    NASA Astrophysics Data System (ADS)

    Korolev, Konstantin A.; Wu, Chuanjian; Yu, Zhong; Sun, Ke; Afsar, Mohammed N.; Harris, Vincent G.

    2018-05-01

    Transmittance measurements have been performed on La-Co substituted barium hexaferrites in millimeter waves. Broadband millimeter-wave measurements have been carried out using the free space quasi-optical spectrometer, equipped with a set of high power backward wave oscillators covering the frequency range of 30 - 120 GHz. Strong absorption zones have been observed in the millimeter-wave transmittance spectra of all La-Co substituted barium hexaferrites due to the ferromagnetic resonance. Linear shift of ferromagnetic resonance frequency as functions of La-Co substitutions have been found. Real and imaginary parts of dielectric permittivity of La-Co substituted barium hexaferrites have been calculated using the analysis of recorded high precision transmittance spectra. Frequency dependences of magnetic permeability of La-Co substituted barium hexaferrites, as well as saturation magnetization and anisotropy field have been determined based on Schlömann's theory for partially magnetized ferrites. La-Co substituted barium hexaferrites have been further investigated by DC magnetization to assess magnetic behavior and compare with millimeter wave data. Consistency of saturation magnetization determined independently by both millimeter wave absorption and DC magnetization have been found for all La-Co substituted barium hexaferrites. These materials seem to be quite promising as tunable millimeter wave absorbers, filters, circulators, based on the adjusting of their substitution parameters.

  19. Surface characterizations of oxides synthesized by successive ionic layer deposition

    NASA Astrophysics Data System (ADS)

    Gilbert, Thomas I.

    Successive ionic layer deposition (SILD) is an aqueous technique for depositing thin oxide films on a surface in a layer-by-layer fashion through a series of chemical reactions. This dissertation examines empirical aspects of the SILD technique by characterizing thin oxide films synthesized on model planar supports and then extends the SILD technique to synthesize supported oxide nanostructures on three dimensional supports of interest to catalysis. Atomic force microscopy, x-ray photoelectron spectroscopy, and scanning electron microscopy provided insight into the SILD of zirconia, alumina, and barium oxide thin films on silicon wafers. The SILD conditions that most affected the surface morphology of the thin oxide films were the selection of aqueous metal salt precursors comprising the SILD solutions and the total number of SILD cycles. Recent studies suggest that a highly dispersed phase of barium oxide supported on alumina interacts differently with NO2 than a bulk-like phase of barium oxide SILD was used to synthesize disperse nanoislands or rafts of barium oxide on larger rafts of alumina supported on a silicon wafer. The SILD method was then extended to deposit barium oxide on an alumina powder support comprised of dense 150 nm spherical crystallites fused together into 1-2 pm particles. Equally weight loaded samples of barium oxide on the fused alumina powder were prepared by SILD and wet impregnation. The NO2 storage behavior of the barium oxide, evaluated by thermogravimetric analysis during NO2 temperature programmed desorption (TPD) experiments, provided insight into the dispersion of barium oxide that resulted from each of the loading techniques. The highly dispersed barium oxide rafts synthesized by SILD on fused alumina released NO2 at temperatures below 500°C during TPD. By comparison, the barium oxide loaded by wet impregnation showed a higher temperature desorption feature above 500°C indicative of bulk-like barium oxide nanoparticles. The NO2 weight loss curves were also used to calculate the relative percentages of BaO in the dispersed phase and bulk-like phase for each loading technique. The ability of SILD to synthesize highly disperse and uniform, conformal oxide coatings on three dimensional supports provides fundamental insight into the interactions between catalysts and supports.

  20. Readout concepts for the suppression of the slow component of BaF2 for the upgrade of the TAPS spectrometer at ELSA

    NASA Astrophysics Data System (ADS)

    Diehl, Stefan; Novotny, Rainer W.; Wohlfahrt, Benjamin; Beck, Reinhard

    2015-02-01

    For the measurement at extremely high interaction rates with fast scintillators, pile-up of consecutive events is a limiting factor. With a decay time of 600 ps of the fast crossluminescence component, Barium Fluoride (BaF2) is one of the fastest inorganic scintillators known today. However, the dominating slow component with a 3 orders of magnitude longer decay time of 630 ns limits the rate capability. To circumvent this limit, different approaches have been made in the past. The slow component can be suppressed for example by doping the crystals with rare earth ions like La3+. The paper will give an overview over the various concepts investigated in the past and present the suppression via optical band pass filters. This method has been chosen for the upgrade of the BaF2 crystals in the most forward region of the TAPS-spectrometer at ELSA in Bonn. It allows to reuse the existing crystals and to achieve a high degree of suppression of the slow component. The focus of the paper will be on the selection of the filters, the achievable rate capability and the energy resolution of the fast component.

  1. One-Step Solvent Evaporation-Assisted 3D Printing of Piezoelectric PVDF Nanocomposite Structures.

    PubMed

    Bodkhe, Sampada; Turcot, Gabrielle; Gosselin, Frederick P; Therriault, Daniel

    2017-06-21

    Development of a 3D printable material system possessing inherent piezoelectric properties to fabricate integrable sensors in a single-step printing process without poling is of importance to the creation of a wide variety of smart structures. Here, we study the effect of addition of barium titanate nanoparticles in nucleating piezoelectric β-polymorph in 3D printable polyvinylidene fluoride (PVDF) and fabrication of the layer-by-layer and self-supporting piezoelectric structures on a micro- to millimeter scale by solvent evaporation-assisted 3D printing at room temperature. The nanocomposite formulation obtained after a comprehensive investigation of composition and processing techniques possesses a piezoelectric coefficient, d 31 , of 18 pC N -1 , which is comparable to that of typical poled and stretched commercial PVDF film sensors. A 3D contact sensor that generates up to 4 V upon gentle finger taps demonstrates the efficacy of the fabrication technique. Our one-step 3D printing of piezoelectric nanocomposites can form ready-to-use, complex-shaped, flexible, and lightweight piezoelectric devices. When combined with other 3D printable materials, they could serve as stand-alone or embedded sensors in aerospace, biomedicine, and robotic applications.

  2. Investigation of optical properties of multilayer dielectric structures using prism-coupling technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sokolov, V I; Glebov, V N; Malyutin, A M

    2015-09-30

    A method based on resonant excitation of waveguide modes with a prism coupler is proposed for measuring the thickness and refractive index of thin-film layers in multilayer dielectric structures. The peculiarities of reflection of TE- and TM-polarised light beams from a structure comprising eleven alternating layers of zinc sulfide (ZnS) and magnesium barium fluoride (MgBaF{sub 4}), whose thicknesses are much less than the wavelength of light, are investigated. Using the mathematical model developed, we have calculated the coefficients of reflection of collimated TE and TM light beams from a multilayer structure and determined the optical constants and thicknesses of themore » structure layers. The refractive indices of the layers, obtained for TE and TM polarisation of incident light, are in good agreement. The thicknesses of ZnS and MgBaF{sub 4} layers, found for different polarisations, coincide with an accuracy of ±1%. Thus, we have demonstrated for the first time that the prism-coupling technique allows one to determine the optical properties of thin-film structures when the number of layers in the structure exceeds ten layers. (integrated optics)« less

  3. Dielectric properties of polyhedral oligomeric silsesquioxane (POSS)-based nanocomposites at 77k

    NASA Astrophysics Data System (ADS)

    Pan, Ming-Jen; Gorzkowski, Edward; McAllister, Kelly

    2011-10-01

    The goal of this study is to develop dielectric nanocomposites for high energy density applications at liquid nitrogen temperature by utilizing a unique nano-material polyhedral oligomeric silsesquioxanes (POSS). A POSS molecule is consisted of a silica cage core with 8 silicon and 12 oxygen atoms and organic functional groups attached to the corners of the cage. In this study, we utilize POSS for the fabrication of nanocomposites both as a silica nanoparticle filler to enhance the breakdown strength and as a surfactant for effective dispersion of high permittivity ceramic nanoparticles in a polymer matrix. The matrix materials selected for the study are polyvinylidene fluoride (PVDF) and poly(methyl methacrylate) (PMMA). The ceramic nanoparticles are barium strontium titanate (BST 50/50) and strontium titanate. The dielectric properties of the solution-cast nanocomposites films were correlated to the composition and processing conditions. We determined that the addition of POSS did not provide enhanced dielectric performance in PVDF- and PMMA-based materials at either room temperature or 77K. In addition, we found that the dielectric breakdown strength of PMMA is lower at 77K than at room temperature, contradicting literature data.

  4. Contactless conductivity detector for microchip capillary electrophoresis

    NASA Technical Reports Server (NTRS)

    Pumera, Martin; Wang, Joseph; Opekar, Frantisek; Jelinek, Ivan; Feldman, Jason; Lowe, Holger; Hardt, Steffen; Svehla, D. (Principal Investigator)

    2002-01-01

    A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation channel. The contactless route obviates problems (e.g., fouling, unwanted reactions) associated with the electrode-solution contact, offers isolation of the detection system from high separation fields, does not compromise the separation efficiency, and greatly simplifies the detector fabrication. Relevant experimental variables, such as the frequency and amplitude of the applied ac voltage or the separation voltage, were examined and optimized. The detector performance was illustrated by the separation of potassium, sodium, barium, and lithium cations and the chloride, sulfate, fluoride, acetate, and phosphate anions. The response was linear (over the 20 microM-7 mM range) and reproducible (RSD = 3.4-4.9%; n = 10), with detection limits of 2.8 and 6.4 microM (for potassium and chloride, respectively). The advantages associated with the contactless conductivity detection, along with the low cost of the integrated PMMA chip/detection system, should enhance the power and scope of microfluidic analytical devices.

  5. Barium strontium titanate thin film growth with variation of lanthanum dopant compatibility as sensor prototype in the satellite technology

    NASA Astrophysics Data System (ADS)

    Mulyadi; Wahyuni, Rika; Hardhienata, Hendradi; Irzaman

    2018-05-01

    Electrical properties of barium strontium titanate thin films were investigated. Three layers of barium strontium titanate thin films have been prepared by chemical solution deposition method and spin coating technique at 8000 rpm rotational speed for 30 seconds and temperature of annealing at 850°C for eight hours with temperature increment of 1.67°C/minute. Materials produced by the process of lanthanum dopant with doping variations of 2%, 4% and 6% above type-p silicon (100) substrates. Film obtained was then carried out the characterization using USB 2000 VIS-NIR and tauc plot method. As a result, the barium strontium titanate thin film has the value of band gap energy of 1.58 eV, 1.92 eV and 2.24 eV respectively. The characterization of electrical properties shows that the band gap value of barium strontium titanate thin film with lanthanum dopant was in the range of semiconductor value. Barium strontium titanate thin films with lanthanum dopant are sensitive to temperature changes, so it potentially to be applied to temperature monitoring on satellite technology.

  6. Improvement of kidney redox states contributes to the beneficial effects of dietary pomegranate peel against barium chloride-induced nephrotoxicity in adult rats.

    PubMed

    Elwej, Awatef; Ghorbel, Imen; Marrekchi, Rim; Boudawara, Ons; Jamoussi, Kamel; Boudawara, Tahia; Zeghal, Najiba; Sefi, Mediha

    2016-07-01

    Pomegranate (Punica granatum L., Punicaceae) is known to possess enormous antioxidant activity. This study investigates the protective effects of pomegranate peel against barium-mediated renal damage. Rats were exposed during 21 days either to barium (67 ppm), barium + pomegranate peel (5% of diet) or to only pomegranate peel (5% of diet). Exposure rats to barium provoked a significant increase in kidney malondialdehyde (MDA), advanced oxidation protein products (AOPP) and hydrogen peroxide (H2O2) levels. Creatinine, urea and uric acid levels in plasma and urine were also modified. Superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GPx) activities, non protein thiol (NPSH) and reduced glutathione (GSH) levels were decreased. Metallothionein (MT) production was increased and their genes expressions were up-regulated. All these changes were improved by dietary pomegranate peel. Moreover, the distorted histoarchitecture in kidney of barium group was alleviated by pomegranate peel. Our data showed, for the first time, the protective effects of pomegranate peel against barium-induced renal oxidative damage.

  7. Transcriptome analysis supports viral infection and fluoride toxicity as contributors to chronic kidney disease of unknown etiology (CKDu) in Sri Lanka.

    PubMed

    Sayanthooran, Saravanabavan; Gunerathne, Lishanthe; Abeysekera, Tilak D J; Magana-Arachchi, Dhammika N

    2018-05-28

    Chronic kidney disease of unknown etiology (CKDu), having epidemic characteristics, is being diagnosed increasingly in certain tropical regions of the world, mainly Latin America and Sri Lanka. They have been observed primarily in farming communities and current hypotheses point toward many environmental and occupational triggers. CKDu does not have common etiologies of chronic kidney disease (CKD) such as hypertension, diabetes, or autoimmune disease. We aimed to understand the molecular processes underlying CKDu in Sri Lanka using transcriptome analysis. RNA extracted from whole blood was reverse transcribed and used for microarray analysis using the Human HT-12 v.4 array (Illumina). Pathway analysis was carried out using ingenuity pathway analysis (IPA-Qiagen). Microarray results were validated using real-time PCR of five selected genes. Pathways related to innate immune response, including interferon signaling, inflammasome signaling and TREM1 signaling had the most significant positive activation z scores, where as EIF2 signaling and mTOR signaling had the most significant negative activation z scores. Pathways previously linked to fluoride toxicity; G-protein activation, Cdc42 signaling, Rac signaling and RhoA signaling were activated in CKDu patients. The most significantly activated biological functions were cell death, cell movement and antimicrobial response. Significant toxicological functions were mitochondrial dysfunction, oxidative stress and apoptosis. Based on the molecular pathway analysis in CKDu patients and review of literature, viral infections and fluoride toxicity appear to be contributing to the molecular mechanisms underlying CKDu.

  8. Barium appendicitis after upper gastrointestinal imaging.

    PubMed

    Novotny, Nathan M; Lillemoe, Keith D; Falimirski, Mark E

    2010-02-01

    Barium appendicitis (BA) is a rarely seen entity with fewer than 30 reports in the literature. However, it is a known complication of barium imaging. To report a case of BA in a patient whose computed tomography (CT) scan was initially read as foreign body ingestion. An 18-year-old man presented with right lower quadrant pain after upper gastrointestinal imaging 2 weeks prior. A CT scan was obtained of his abdomen and pelvis that revealed a finding that was interpreted as a foreign body at the area of the terminal ileum. A plain X-ray study of the abdomen revealed radiopaque appendicoliths. Pathology confirmed the diagnosis of barium appendicitis. BA is a rare entity and the pathogenesis is unclear. Shorter intervals between barium study and presentation with appendicitis usually correlate with fewer complications. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  9. Comparison of barium swallow and ultrasound in diagnosis of gastro-oesophageal reflux in children.

    PubMed Central

    Naik, D R; Bolia, A; Moore, D J

    1985-01-01

    Fifty one infants and older children with suspected gastro-oesophageal reflux entered a study comparing the diagnostic accuracy of a standard barium swallow examination with that of ultrasound scanning. All children were examined by both techniques. In 40 cases there was unequivocal agreement between the examinations. Of the remaining patients, four had definite reflux by ultrasonic criteria but showed no evidence of reflux on barium swallow examination, four had positive findings on ultrasound but showed only minimal reflux on barium swallow, and one showed minimal reflux on ultrasound but had a negative barium meal result. In two children the ultrasound study was inconclusive. Ultrasound has an important role in the diagnosis and follow up of patients under the age of 5 years with gastro-oesophageal reflux. Images FIG 1 FIG 2 PMID:3924317

  10. Barium-induced skeletal muscle paralysis in the rat, and its relationship to human familial periodic paralysis

    PubMed Central

    Schott, G. D.; McArdle, B.

    1974-01-01

    An in vivo study of skeletal muscle paralysis induced by intravenous barium chloride has been made in curarized and non-curarized rats. The influence of potassium and calcium chlorides, propranolol, ouabain, and prior adrenalectomy on the paralysis has also been studied. Paralysis is found to be due to a direct effect on skeletal muscle, and to correlate well with the development of hypokalaemia. Possible mechanisms of action of barium are discussed, and attention is drawn to the similarity between barium poisoning and hypokalaemic familial periodic paralysis. PMID:4813426

  11. A high-altitude barium radial injection experiment

    NASA Technical Reports Server (NTRS)

    Wescott, E. M.; Stenbaek-Nielsen, H. C.; Hallinan, T. J.; Deehr, C. S.; Romick, G. J.; Olson, J. V.; Roederer, J. G.; Sydora, R.

    1980-01-01

    A rocket launched from Poker Flat, Alaska, carried a new type of high-explosive barium shaped charge to 571 km, where detonation injected a thin disk of barium vapor with high velocity nearly perpendicular to the magnetic field. The TV images of the injection are spectacular, revealing three major regimes of expanding plasma which showed early instabilities in the neutral gas. The most unusual effect of the injection is a peculiar rayed barium-ion structure lying in the injection plane and centered on a 5 km 'black hole' surrounding the injection point. Preliminary electrostatic computer simulations show a similar rayed development.

  12. Enhanced constitutive invasion activity in human nontumorigenic keratinocytes exposed to a low level of barium for a long time.

    PubMed

    Thang, Nguyen D; Yajima, Ichiro; Ohnuma, Shoko; Ohgami, Nobutaka; Kumasaka, Mayuko Y; Ichihara, Gaku; Kato, Masashi

    2015-02-01

    We have recently demonstrated that exposure to barium for a short time (≤4 days) and at a low level (5 µM = 687 µg/L) promotes invasion of human nontumorigenic HaCaT cells, which have characteristics similar to those of normal keratinocytes, suggesting that exposure to barium for a short time enhances malignant characteristics. Here we examined the effect of exposure to low level of barium for a long time, a condition mimicking the exposure to barium through well water, on malignant characteristics of HaCaT keratinocytes. Constitutive invasion activity, focal adhesion kinase (FAK) protein expression and activity, and matrix metalloproteinase 14 (MMP14) protein expression in primary cultured normal human epidermal keratinocytes, HaCaT keratinocytes, and HSC5 and A431 human squamous cell carcinoma cells were augmented following an increase in malignancy grade of the cells. Constitutive invasion activity, FAK phosphorylation, and MMP14 expression levels of HaCaT keratinocytes after treatment with 5 µM barium for 4 months were significantly higher than those of control untreated HaCaT keratinocytes. Taken together, our results suggest that exposure to a low level of barium for a long time enhances constitutive malignant characteristics of HaCaT keratinocytes via regulatory molecules (FAK and MMP14) for invasion. © 2013 Wiley Periodicals, Inc.

  13. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough*,**

    PubMed Central

    Nin, Carlos Shuler; Marchiori, Edson; Irion, Klaus Loureiro; Paludo, Artur de Oliveira; Alves, Giordano Rafael Tronco; Hochhegger, Daniela Reis; Hochhegger, Bruno

    2013-01-01

    OBJECTIVE: To assess the routine use of barium swallow study in patients with chronic cough. METHODS: Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks) were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons. RESULTS: The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6%) of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6%) of the patients, whereas the treatment was ineffective in 1 (8.4%). We observed no complications related to barium swallow, such as contrast aspiration. CONCLUSIONS: Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies. PMID:24473762

  14. Acute barium intoxication following ingestion of ceramic glaze.

    PubMed Central

    Thomas, M.; Bowie, D.; Walker, R.

    1998-01-01

    A case of deliberate overdose of barium sulphide in a psychiatric setting is presented, with resulting flaccid paralysis, malignant arrhythmia, respiratory arrest and severe hypokalaemia, but ultimately with complete recovery. The degree of paralysis appears to be related directly to serum barium levels. The value of early haemodialysis, particularly with respiratory paralysis and hypokalaemia, is emphasised. PMID:10211330

  15. A randomised clinical evaluation of a fluoride mouthrinse and dentifrice in an in situ caries model.

    PubMed

    Parkinson, Charles R; Hara, Anderson T; Nehme, Marc; Lippert, Frank; Zero, Domenick T

    2018-03-01

    Fluoride mouthrinses provide advantages for fluoride delivery by maintaining elevated intra-oral fluoride concentrations following fluoride dentifrice use. This in situ caries study investigated potential anti-caries efficacy of a 220 ppm fluoride mouthrinse. This was an analyst-blinded, four-treatment, randomised, crossover study using partially demineralised, gauze-wrapped, human enamel samples mounted in a mandibular partial denture. Participants brushed twice daily for 14 days with either a 1150 ppm fluoride or a fluoride-free placebo dentifrice and either rinsed once daily with the 220 ppm fluoride mouthrinse or not. Following each treatment period, percent surface microhardness recovery (%SMHR) and enamel fluoride uptake (EFU) were assessed. Fifty three participants completed the study. Compared with the placebo dentifrice/no rinse treatment, the fluoride-containing regimens demonstrated greater enamel remineralisation (%SMHR) and fluoridation (EFU): fluoride dentifrice/fluoride rinse (%SMHR difference: 21.55 [95% CI: 15.78,27.32]; EFU difference 8.35 [7.21,9.29]); fluoride dentifrice/no rinse: 19.48 [13.81,25.15]; 6.47 [5.35,7.60]; placebo dentifrice/fluoride rinse: 16.76 [11.06,22.45]; 5.87 [4.72,7.00] (all P < .0001). There were no significant differences in%SMHR between fluoride regimens. The fluoride dentifrice/fluoride rinse regimen was associated with higher EFU than the fluoride dentifrice/no rinse (1.88 [0.75,3.01], P = .0013) and placebo dentifrice/fluoride rinse regimens (2.48 [1.34,3.62], P < .0001). Treatments were generally well-tolerated. The in situ caries model demonstrated that the fluoride mouthrinse is effective in promoting enamel caries lesion remineralisation and fluoridation whether used following a fluoride or non-fluoride dentifrice. Additive (potential) anti-caries benefits of a fluoride rinse after a fluoride dentifrice were confined to enhancements in lesion fluoridation (EFU). In conjunction with a fluoride dentifrice, fluoride mouthrinses enhance enamel fluoridation, which may be useful in caries prevention. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Contemporary biological markers of exposure to fluoride.

    PubMed

    Rugg-Gunn, Andrew John; Villa, Alberto Enrique; Buzalaf, Marília Rabelo Afonso

    2011-01-01

    Contemporary biological markers assess present, or very recent, exposure to fluoride: fluoride concentrations in blood, bone surface, saliva, milk, sweat and urine have been considered. A number of studies relating fluoride concentration in plasma to fluoride dose have been published, but at present there are insufficient data on plasma fluoride concentrations across various age groups to determine the 'usual' concentrations. Although bone contains 99% of the body burden of fluoride, attention has focused on the bone surface as a potential marker of contemporary fluoride exposure. From rather limited data, the ratio surface-to-interior concentration of fluoride may be preferred to whole bone fluoride concentration. Fluoride concentrations in the parotid and submandibular/sublingual ductal saliva follow the plasma fluoride concentration, although at a lower concentration. At present, there are insufficient data to establish a normal range of fluoride concentrations in ductal saliva as a basis for recommending saliva as a marker of fluoride exposure. Sweat and human milk are unsuitable as markers of fluoride exposure. A proportion of ingested fluoride is excreted in urine. Plots of daily urinary fluoride excretion against total daily fluoride intake suggest that daily urinary fluoride excretion is suitable for predicting fluoride intake for groups of people, but not for individuals. While fluoride concentrations in plasma, saliva and urine have some ability to predict fluoride exposure, present data are insufficient to recommend utilizing fluoride concentrations in these body fluids as biomarkers of contemporary fluoride exposure for individuals. Daily fluoride excretion in urine can be considered a useful biomarker of contemporary fluoride exposure for groups of people, and normal values have been published. Copyright © 2011 S. Karger AG, Basel.

  17. Barium inhibits arsenic-mediated apoptotic cell death in human squamous cell carcinoma cells.

    PubMed

    Yajima, Ichiro; Uemura, Noriyuki; Nizam, Saika; Khalequzzaman, Md; Thang, Nguyen D; Kumasaka, Mayuko Y; Akhand, Anwarul A; Shekhar, Hossain U; Nakajima, Tamie; Kato, Masashi

    2012-06-01

    Our fieldwork showed more than 1 μM (145.1 μg/L) barium in about 3 μM (210.7 μg/L) arsenic-polluted drinking well water (n = 72) in cancer-prone areas in Bangladesh, while the mean concentrations of nine other elements in the water were less than 3 μg/L. The types of cancer include squamous cell carcinomas (SCC). We hypothesized that barium modulates arsenic-mediated biological effects, and we examined the effect of barium (1 μM) on arsenic (3 μM)-mediated apoptotic cell death of human HSC-5 and A431 SCC cells in vitro. Arsenic promoted SCC apoptosis with increased reactive oxygen species (ROS) production and JNK1/2 and caspase-3 activation (apoptotic pathway). In contrast, arsenic also inhibited SCC apoptosis with increased NF-κB activity and X-linked inhibitor of apoptosis protein (XIAP) expression level and decreased JNK activity (antiapoptotic pathway). These results suggest that arsenic bidirectionally promotes apoptotic and antiapoptotic pathways in SCC cells. Interestingly, barium in the presence of arsenic increased NF-κB activity and XIAP expression and decreased JNK activity without affecting ROS production, resulting in the inhibition of the arsenic-mediated apoptotic pathway. Since the anticancer effect of arsenic is mainly dependent on cancer apoptosis, barium-mediated inhibition of arsenic-induced apoptosis may promote progression of SCC in patients in Bangladesh who keep drinking barium and arsenic-polluted water after the development of cancer. Thus, we newly showed that barium in the presence of arsenic might inhibit arsenic-mediated cancer apoptosis with the modulation of the balance between arsenic-mediated promotive and suppressive apoptotic pathways.

  18. The Interaction Between Accretion from the Interstellar Medium and Accretion from the Evolved Binary Component in Barium Stars

    NASA Astrophysics Data System (ADS)

    Jeong, Yeuncheol; Yushchenko, Alexander V.; Doikov, Dmytry N.

    2018-03-01

    The reanalysis of the previously published abundance pattern of mild barium star HD202109 (ζ Cyg) and the chemical compositions of 129 thin disk barium stars facilitated the search for possible correlations of different stellar parameters with second ionization potentials of chemical elements. Results show that three valuable correlations exist in the atmospheres of barium stars. The first is the relationship between relative abundances and second ionization potentials. The second is the age dependence of mean correlation coefficients of relative abundances vs. second ionization potentials, and the third one is the changes in correlation coefficients of relative abundances vs. second ionization potentials as a function of stellar spatial velocities and overabundances of s-process elements. These findings demonstrate the possibility of hydrogen and helium accretion from the interstellar medium on the atmospheres of barium stars.

  19. The value of the preoperative barium-enema examination in the assessment of pelvic masses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gedgaudas, R.K.; Kelvin, F.M.; Thompson, W.M.

    1983-03-01

    The value of the barium-enema examination in the assessment of pelvic masses was studied in 44 patients. Findings from those barium-enema examinations and from pathological specimens from 37 patients who had malignant tumors and seven patients who had endometriosis were retrospectively analyzed to determine if the barium-enema examination is useful in differentiating extrinsic lesions with and without invasion of the colon. None of the 12 patients who had extrinsic lesions had any of the criteria that indicated bowel-wall invasion. These criteria included fixation and serrations of the bowel wall in all patients with invasion, and ulceration and fistulizaton in thosemore » patients who had complete transmural invasion. In patients with pelvic masses, the preoperative barium-enema examination may be useful to the surgeon in planning surgery and in preparing the patient for the possibility of partial colectomy or colostomy.« less

  20. Fluoride mechanisms.

    PubMed

    ten Cate, J M; van Loveren, C

    1999-10-01

    This article discusses fluoride mechanisms in relation to dental caries. The authors specifically address firmly bound versus loosely bound fluoride; different fluoride active ingredients; fluoride and demineralization and remineralization; fluoride slow-release devices and F-releasing dental materials; antimicrobial effects of fluoride; the uptake of fluoride by oral bacteria; inhibition of enolase, protein-intruding ATPase and sugar transport; the various aspects of plaque as it relates to fluoride; and the rational use of fluoride.

  1. Non-Reciprocal on Wafer Microwave Devices

    DTIC Science & Technology

    2015-05-27

    filter uses a barium hexagonal ferrite film incorporated into the dielectric layer of a microstrip transmission line. The zero-field operational...Fal,, Robert E. Camley. Millimeter wave phase shifter based on ferromagnetic resonancein a hexagonal barium ferrite thin film, Applied Physics...materials for on-wafer microwave devices concentrated on barium hexagonal ferrite (BaM) films grown on Si because these material is a good candidate

  2. Installation Restoration Program. Phase 2. Confirmation/Quantification. Stage 1. Sites 24-WF15, 25-WF22 and 26-BST5. U.S. Air Force Plant No. 42, Palmdale, California.

    DTIC Science & Technology

    1988-06-15

    Primary Metals: CA Title 2:60 e Arsenic 0.005 mg/L~~ Barium 0.005 mg/LICadmium 0.005 mg/L Chromium 0.01 mg/L Lead 0.05 mg/L Mercury 0.001 mg/L Selenium...analyzed for twelve metals: arsenic (As), barium (Ba), cadmium (Ca), chromium (COr), lead (Pb), mer- cury (Hg), selenium (Se), silver (Ag), iron (Fe...Total Threshold Limit Substnce (mg/L) (mg/Kg) Arsenic 5.0 500 Barium (excludingf barium sulfate) 100 10,000 Cadmium 1.0 100 Chromium VI 5 500 Chromium

  3. Acceleration of barium ions near 8000 km above an aurora

    NASA Technical Reports Server (NTRS)

    Stenbaek-Nielsen, H. C.; Hallinan, T. J.; Wescott, E. M.; Foeppl, H.

    1984-01-01

    A barium shaped charge, named Limerick, was released from a rocket launched from Poker Flat Research Range, Alaska, on March 30, 1982, at 1033 UT. The release took place in a small auroral breakup. The jet of ionized barium reached an altitude of 8100 km 14.5 min after release, indicating that there were no parallel electric fields below this altitude. At 8100 km the jet appeared to stop. Analysis shows that the barium at this altitude was effectively removed from the tip. It is concluded that the barium was actually accelerated upward, resulting in a large decrease in the line-of-sight density and hence the optical intensity. The parallel electric potential in the acceleration region must have been greater than 1 kV over an altitude interval of less than 200 km. The acceleration region, although presumably auroral in origin, did not seem to be related to individual auroral structures, but appeared to be a large-scale horizontal structure. The perpendicular electric field below, as deduced from the drift of the barium, was temporally and spatially very uniform and showed no variation related to individual auroral structures passing through.

  4. Growth and characterization of high-performance photorefractive BaTiO3 crystals

    NASA Technical Reports Server (NTRS)

    Warde, C.; Garrett, M. H.; Chang, J. Y.; Jenssen, H. P.; Tuller, H. L.

    1991-01-01

    Barium titanate has been used for many nonlinear optical applications primarily because it has high grain and high self-pumped phase conjugate reflectivities. However, barium titanate has had a relatively slow response time, and thus low sensitivity. Therefore, it has not been suited to real-time operations. In this report we will describe the modifications in crystal growth, doping, reduction, and poling that have produced barium titanate crystals with the fastest photorefractive response time reported to date, approximately 21 microseconds with a beam-coupling gain coefficient of 38.7 cm(exp -1) and the highest sensitivity reported to date of 3.44 cm(exp 3)/kJ. The sensitivity of these barium titanate crystals is comparable to or greater than other photorefractive oxides. We will show, for the first time, beam-coupling in barium titanate at video frame rates. We infer from response time measurements that barium titanate has a phonon limited mobility. Also, photorefractive response time measurements as a function of the crystallographic orientation and grating wave vector for our cobalt-doped oxygen reduced crystals indicate that their faster response time arise because of an increase in the free carrier lifetime.

  5. An exacting transition probability measurement - a direct test of atomic many-body theories.

    PubMed

    Dutta, Tarun; De Munshi, Debashis; Yum, Dahyun; Rebhi, Riadh; Mukherjee, Manas

    2016-07-19

    A new protocol for measuring the branching fraction of hydrogenic atoms with only statistically limited uncertainty is proposed and demonstrated for the decay of the P3/2 level of the barium ion, with precision below 0.5%. Heavy hydrogenic atoms like the barium ion are test beds for fundamental physics such as atomic parity violation and they also hold the key to understanding nucleo-synthesis in stars. To draw definitive conclusion about possible physics beyond the standard model by measuring atomic parity violation in the barium ion it is necessary to measure the dipole transition probabilities of low-lying excited states with a precision better than 1%. Furthermore, enhancing our understanding of the barium puzzle in barium stars requires branching fraction data for proper modelling of nucleo-synthesis. Our measurements are the first to provide a direct test of quantum many-body calculations on the barium ion with a precision below one percent and more importantly with no known systematic uncertainties. The unique measurement protocol proposed here can be easily extended to any decay with more than two channels and hence paves the way for measuring the branching fractions of other hydrogenic atoms with no significant systematic uncertainties.

  6. 10 CFR 30.71 - Schedule B.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... (Sb 125) 10 Arsenic 73 (As 73) 100 Arsenic 74 (As 74) 10 Arsenic 76 (As 76) 10 Arsenic 77 (As 77) 100 Barium 131 (Ba 131) 10 Barium 133 (Ba 133) 10 Barium 140 (Ba 140) 10 Bismuth 210 (Bi 210) 1 Bromine 82....1 [35 FR 6427, Apr. 22, 1970, as amended at 36 FR 16898, Aug. 26, 1971; 59 FR 5519, Feb. 7, 1994; 72...

  7. 10 CFR 30.71 - Schedule B.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... (Sb 125) 10 Arsenic 73 (As 73) 100 Arsenic 74 (As 74) 10 Arsenic 76 (As 76) 10 Arsenic 77 (As 77) 100 Barium 131 (Ba 131) 10 Barium 133 (Ba 133) 10 Barium 140 (Ba 140) 10 Bismuth 210 (Bi 210) 1 Bromine 82....1 [35 FR 6427, Apr. 22, 1970, as amended at 36 FR 16898, Aug. 26, 1971; 59 FR 5519, Feb. 7, 1994; 72...

  8. 'Skidding' of the CRRES G-9 barium release

    NASA Technical Reports Server (NTRS)

    Huba, J. D.; Mitchell, H. G.; Fedder, J. A.; Bernhardt, P. A.

    1992-01-01

    A simulation study and experimental data of the CRRES G-9 ionospheric barium release are presented. The simulation study is based on a 2D electrostatic code that incorporates time-dependent coupling to the background plasma. It is shown that the densest portion of the barium ion cloud 'skids' about 15 km within the first three seconds following the release, consistent with the optical data analyses.

  9. Fluoride intake of infants living in non-fluoridated and fluoridated areas.

    PubMed

    Zohoori, F V; Whaley, G; Moynihan, P J; Maguire, A

    2014-01-01

    Data on fluoride exposure of infants are sparse. This study aimed to estimate total daily fluoride intake (TDFI) of infants aged 1-12 months, living in non-fluoridated and fluoridated areas in north-east England. Daily dietary fluoride intake was assessed using a three-day food diary coupled with analysis of fluoride content of food/drink consumed, using a F-ISE and diffusion method. A questionnaire with an interview was used to collect information on toothbrushing habits. TDFI was estimated from diet, plus fluoride supplements and dentifrice ingestion where used. Thirty-eight infants completed the study; 19 receiving fluoridated water (mean 0.97 mgF/l) and 19 receiving non-fluoridated water (mean 0.19 mgF/l). Mean (SD) TDFI for the infants living in fluoridated and non-fluoridated areas was 0.107 (0.054) and 0.024 (0.015) mg/kg body weight per day, respectively. Diet was the only fluoride source for 87% of infants and none used fluoride supplements. For infants for whom mouth/teeth cleaning was undertaken, dentifrice contribution to TDFI ranged from 24 to 78%. Infants living in fluoridated areas, in general, may receive a fluoride intake, from diet only, of more than the suggested optimal range for TDFI. This emphasises the importance of estimating TDFI at an individual level when recommendations for fluoride use are being considered.

  10. Estimated dietary fluoride intake for New Zealanders.

    PubMed

    Cressey, Peter; Gaw, Sally; Love, John

    2010-01-01

    Existing fluoride concentration and consumption data were used to estimate fluoride intakes from the diet and toothpaste use, for New Zealand subpopulations, to identify any population groups at risk of high-fluoride intake. For each sub-population, two separate dietary intake estimates were made--one based on a non-fluoridated water supply (fluoride concentration of 0.1 mg/L), and the other based on a water supply fluoridated to a concentration of 1.0 mg/L. Fluoride concentration data were taken from historical surveys, while food consumption data were taken from national 24-hour dietary recall surveys or from simulated diets. Mean and 95th percentile estimations of dietary fluoride intake were well below the upper level of intake (UL), whether intakes were calculated on the basis of a non-fluoridated or fluoridated water supply. The use of fluoride-containing toothpastes provides additional fluoride intake. For many of the population groups considered, mean fluoride intakes were below the adequate intake (AI) level for caries protection, even after inclusion of the fluoride contribution from toothpaste. Intake of fluoride was driven by consumption of dietary staples (bread, potatoes),beverages (particularly tea, soft drinks, and beer), and the fluoride status of drinking water. Estimates of fluoride intake from the diet and toothpaste did not identify any groups at risk of exceeding the UL, with the exception of infants (6-12 months) living in areas with fluoridated water supplies and using high-fluoride toothpaste. In contrast, much of the adult population may be receiving insufficient fluoride for optimum caries protection from these sources, as represented by the AI.

  11. Fluoride toothpastes and fluoride mouthrinses for home use.

    PubMed

    Rugg-Gunn, Andrew; Bánóczy, Jolán

    2013-11-01

    To provide a brief commentary review of fluoride-containing toothpastes and mouthrinses with emphasis on their use at home. Toothpastes and mouthrinses are just two of many ways of providing fluoride for the prevention of dental caries. The first investigations into incorporating fluoride into toothpastes and mouthrinses were reported in the middle 1940s. Unlike water fluoridation (which is 'automatic fluoridation'), fluoride-containing toothpastes and fluoridecontaining mouthrinses are, primarily, for home use and need to be purchased by the individual. By the 1960s, research indicated that fluoride could be successfully incorporated into toothpastes and clinical trials demonstrated their effectiveness. By the end of the 1970s, almost all toothpastes contained fluoride. The widespread use of fluoride- containing toothpastes is thought to be the main reason for much improved oral health in many countries. Of the many fluoride compounds investigated, sodium fluoride, with a compatible abrasive, is the most popular, although amine fluorides are used widely in Europe. The situation is similar for mouthrinses. Concentrations of fluoride (F), commonly found, are 1500 ppm (1500 μg F/g) for toothpastes and 225 ppm (225 μg F/ml) for mouthrinse. Several systematic reviews have concluded that fluoride-containing toothpastes and mouthrinses are effective, and that there is added benefit from their use with other fluoride delivery methods such as water fluoridation. Guidelines for the appropriate use of fluoride toothpastes and mouthrinses are available in many countries. Fluoride toothpastes and mouthrinses have been developed and extensive testing has demonstrated that they are effective and their use should be encouraged. Copyright © 2013 by Academy of Sciences and Arts of Bosnia and Herzegovina.

  12. Use of barium-strontium carbonatite for flux welding and surfacing of mining machines

    NASA Astrophysics Data System (ADS)

    Kryukov, R. E.; Kozyrev, N. A.; Usoltsev, A. A.

    2017-09-01

    The results of application of barium-strontium carbonatite for modifying and refining iron-carbon alloys, used for welding and surfacing in ore mining and smelting industry, are generalized. The technology of manufacturing a flux additive containing 70 % of barium-strontium carbonatite and 30 % of liquid glass is proposed. Several compositions of welding fluxes based on silicomanganese slag were tested. The flux additive was introduced in an amount of 1, 3, 5 %. Technological features of welding with the application of the examined fluxes are determined. X-ray spectral analysis of the chemical composition of examined fluxes, slag crusts and weld metal was carried out, as well as metallographic investigations of welded joints. The principal possibility of applying barium-strontium carbonatite as a refining and gas-protective additive for welding fluxes is shown. The use of barium-strontium carbonatite reduces the contamination of the weld seam with nonmetallic inclusions: non-deforming silicates, spot oxides and brittle silicates, and increases the desulfurizing capacity of welding fluxes.

  13. SEPARATION OF BARIUM VALUES FROM URANYL NITRATE SOLUTIONS

    DOEpatents

    Tompkins, E.R.

    1959-02-24

    The separation of radioactive barium values from a uranyl nitrate solution of neutron-irradiated uranium is described. The 10 to 20% uranyl nitrate solution is passed through a flrst column of a cation exchange resin under conditions favoring the adsorption of barium and certain other cations. The loaded resin is first washed with dilute sulfuric acid to remove a portion of the other cations, and then wash with a citric acid solution at pH of 5 to 7 to recover the barium along with a lesser amount of the other cations. The PH of the resulting eluate is adjusted to about 2.3 to 3.5 and diluted prior to passing through a smaller second column of exchange resin. The loaded resin is first washed with a citric acid solution at a pH of 3 to elute undesired cations and then with citric acid solution at a pH of 6 to eluts the barium, which is substantially free of undesired cations.

  14. Assessment of Barium Sulphate Formation and Inhibition at Surfaces with Synchrotron X-ray Diffraction (SXRD)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    E Mavredaki; A Neville; K Sorbie

    2011-12-31

    The precipitation of barium sulphate from aqueous supersaturated solutions is a well-known problem in the oil industry often referred to as 'scaling'. The formation and growth of barite on surfaces during the oil extraction process can result in malfunctions within the oil facilities and serious damage to the equipment. The formation of barium sulphate at surfaces remains an important topic of research with the focus being on understanding the mechanisms of formation and means of control. In situ synchrotron X-ray diffraction (SXRD) was used to investigate the formation of barium sulphate on a stainless steel surface. The effect of Poly-phosphinocarboxylicmore » acid (PPCA) and Diethylenetriamine-penta-methylenephosphonic acid (DETPMP) which are two commercial inhibitors for barium sulphate was examined. The in situ SXRD measurements allowed the identification of the crystal faces of the deposited barite in the absence and presence of the two inhibitors. The preferential effect of the inhibitors on some crystal planes is reported and the practical significance discussed.« less

  15. Characterization of Barium Borate Frameworks Using Raman Spectroscopy.

    PubMed

    Gharavi-Naeini, Jafar; Yoo, Kyung W; Stump, Nathan A

    2018-04-01

    Systematic micro-Raman scattering investigations have been carried out on Sm +2 doped 2(BaO)-n(B 2 O 3 ) matrices for n = 4, 5, 8, and 2(BaO)-(Na 2 O)-9(B 2 O 3 ) using the 364 nm excitation of an Ar + laser. The Raman results have been compared with the known structures of barium tetraborate, barium pentaborate, barium octaborate, and barium sodium nonaborate. An excellent correlation has been found between the BO 4 /BO 3 composition ratios for each product and intensity ratios of the designated BO 4 and BO 3 Raman peaks. Furthermore, the Raman frequencies of both BO 4 and BO 3 groups undergo a systematic blueshift as n increases from four to nine. The shift results from a decrease of the B-O bond lengths for both BO 4 and BO 3 groups as the samples transition from the tetraborate to nonaborate structures. Linear relations (with negative slopes) have been determined between the measured Raman frequencies and B-O bond lengths in the frameworks.

  16. Calculated emission rates for barium releases in space

    NASA Technical Reports Server (NTRS)

    Stenbaek-Nielsen, H. C.

    1989-01-01

    The optical emissions from barium releases in space are caused by resonance and fluorescent scattering of sunlight. Emission rates for the dominant ion and neutral lines are calculated assuming the release to be optically thin and the barium to be in radiative equilibrium with the solar radiation. The solar spectrum has deep Fraunhofer absorption lines at the primary barium ion resonances. A velocity component toward or away from the sun will Doppler shift the emission lines relative to the absorption lines and the emission rates will increase many-fold over the rest value. The Doppler brightening is important in shaped charge or satellite releases where the barium is injected at high velocities. Emission rates as a function of velocity are calculated for the 4554, 4934, 5854, 6142 and 6497 A ion emission lines and the dominant neutral line at 5535 A. Results are presented for injection parallel to the ambient magnetic field, B, and for injection at an angle to B.

  17. Oral fluoride retention after use of fluoride dentifrices.

    PubMed

    Duckworth, R M; Morgan, S N

    1991-01-01

    Fluoride is the only extensively clinically proven means of reducing dental caries. Despite a large body of epidemiological data on the effectiveness of fluoride, delivered in the form of dentifrices, mouthrinses, drinking water, etc., the precise mode of action of fluoride is not completely understood. The purpose of this paper is to report an investigation of the link between oral fluoride levels and applied fluoride dose from dentifrices. Human salivary fluoride clearance studies and equilibrium baseline studies of fluoride in saliva and plaque have been carried out with dentifrices which contained 1,000, 1,500 and 2,500 micrograms fluoride per gram as sodium monofluorophosphate. After a single brushing with a fluoride dentifrice, salivary fluoride decreased in two distinct phases: an initial rapid phase which lasted for 40-80 min, depending on the individual, and a second slow phase lasting for several hours. The latter phase is believed to be due to fluoride released from an oral fluoride reservoir. During regular repeated use of the test dentifrices, the equilibrium baseline fluoride concentration, attained in both saliva and plaque between one application and the next, increased significantly compared with placebo values. Such elevated baseline fluoride concentrations also increased with increasing Na2FPO3 content of the dentifrices. The present work supports the concept that labile fluoride, stored in an oral fluoride reservoir at the time of treatment application, may maintain a prolonged protective effect against dental caries.

  18. Calibration of equipment for analysis of drinking water fluoride: a comparison study.

    PubMed

    Quock, Ryan L; Chan, Jarvis T

    2012-03-01

    Current American Dental Association evidence-based recommendations for prescription of dietary fluoride supplements are based in part on the fluoride concentration of a pediatric patient's drinking water. With these recommendations in mind, this study compared the relative accuracy of fluoride concentration analysis when a common apparatus is calibrated with different combinations of standard values. Fluoride solutions in increments of 0.1 ppm, from a range of 0.1 to 1.0 ppm fluoride, as well as 2.0 and 4.0 ppm, were gravimetrically prepared and fluoride concentration measured in pentad, using a fluoride ion-specific electrode and millivolt meter. Fluoride concentrations of these solutions were recorded after calibration with the following 3 different combinations of standard fluoride solutions: 0.1 ppm and 0.5 ppm, 0.1 ppm and 1.0 ppm, 0.5 ppm and 1.0 ppm. Statistical analysis showed significant differences in the fluoride content of water samples obtained with different two-standard fluoride solutions. Among the two-standard fluoride solutions tested, using 0.5 ppm and 1.0 ppm as two-standard fluoride solutions provided the most accurate fluoride measurement of water samples containing fluoride in the range of 0.1 ppm to 4.0 ppm. This information should be valuable to dental clinics or laboratories in fluoride analysis of drinking water samples.

  19. Yielding Unexpected Results: Precipitation of Ba[subscript3](PO[subscript4])[subscript2] and Implications for Teaching Solubility Principles in the General Chemistry Curriculum

    ERIC Educational Resources Information Center

    Hazen, Jeffery L.; Cleary, David A.

    2014-01-01

    Precipitation of barium phosphate from aqueous solutions of a barium salt and a phosphate salt forms the basis for a number of conclusions drawn in general chemistry. For example, the formation of a solid white precipitate is offered as evidence that barium phosphate is insoluble. Furthermore, analysis of the supernatant is used to illustrate the…

  20. Colonoscopy can miss diverticula of the left colon identified by barium enema.

    PubMed

    Niikura, Ryota; Nagata, Naoyoshi; Shimbo, Takuro; Akiyama, Junichi; Uemura, Naomi

    2013-04-21

    To identify the diagnostic value of colonoscopy for diverticulosis as determined by barium enema. A total of 65 patients with hematochezia who underwent colonoscopy and barium enema were analyzed, and the diagnostic value of colonoscopy for diverticula was assessed. The receiver operating characteristic area under the curve was compared in relation to age (< 70 or ≥ 70 years), sex, and colon location. The number of diverticula was counted, and the detection ratio was calculated. Colonic diverticula were observed in 46 patients with barium enema. Colonoscopy had a sensitivity of 91% and specificity of 90%. No significant differences were found in the receiver operating characteristic area under the curve (ROC-AUC) for age group or sex. The ROC-AUC of the left colon was significantly lower than that of the right colon (0.81 vs 0.96, P = 0.02). Colonoscopy identified 486 colonic diverticula, while barium enema identified 1186. The detection ratio for the entire colon was therefore 0.41 (486/1186). The detection ratio in the left colon (0.32, 189/588) was significantly lower than that of the right colon (0.50, 297/598) (P < 0.01). Compared with barium enema, only half the number of colonic diverticula can be detected by colonoscopy in the entire colon and even less in the left colon.

  1. Chromospherically active stars. 11: Giant with compact hot companions and the barium star scenario

    NASA Technical Reports Server (NTRS)

    Fekel, Francis C.; Henry, Gregory W.; Busby, Michael R.; Eitter, Joseph J.

    1993-01-01

    We have determined spectroscopic orbits for three chromsopherically active giants that have hot compact companions. They are HD 160538 (KO III + wd, P = 904 days), HD 165141 (G8 III + wd, P approximately 5200 days), and HD 185510 (KO III + sdB, P = 20.6619 days). By fitting an IUE spectrum with theoretical models, we find the white dwarf companion of HD 165141 has a temperature of about 35,000 K. Spectral types and rotational velocities have been determined for the three giants and distances have been estimated. These three systems and 39 Ceti are compared with the barium star mass-transfer scenario. The long-period mild barium giant HD 165141 as well as HD 185510 and 39 Ceti, which have relatively short periods and normal abundance giants, appear to be consistent with this scenario. The last binary, HD 160538, a system with apparently near solar abundances, a white dwarf companion, and orbital characteristics similar to many barium stars, demonstrates that the existence of a white dwarf companion is insufficient to produce a barium star. The paucity of systems with confirmed white dwarf companions makes abundance analyses of HD 160538 and HD 165141 of great value in examining the role of metallicity in barium star formation.

  2. Chromospherically active stars. 6: Giants with compact hot companions and the barium star scenario

    NASA Technical Reports Server (NTRS)

    Fekel, Francis C.; Henry, Gregory W.; Busby, Michael R.; Eitter, Joseph J.

    1993-01-01

    We have determined spectroscopic orbits for three chromospherically active giants that have hot compact companions. They are HD 160538 (K0 III + wd, P = 904 days), HD 165141 (G8 III + wd, P approximately 5200 days), and HD 185510 (K0 III + sdB, P = 20.6619 days). By fitting an IUE spectrum with theoretical models, we find the white dwarf companion of HD 165141 has a temperature of about 35000 K. Spectral types and rotational velocities have been determined for the three giants and distances have been estimated. These three systems and 39 Ceti are compared with the barium star mass-transfer scenario. The long-period mild barium giant HD 165141 as well as HD 185510 and 39 Ceti, which have relatively short periods and normal abundance giants, appear to be consistent with this scenario. The last binary, HD 160538, a system with apparently near solar abundances, a white dwarf companion, and orbital characteristics similar to many barium stars, demonstrates that the existence of a white-dwarf companion is insufficient to produce a barium star. The paucity of systems with confirmed white-dwarf companions makes abundance analyses of HD 160538 and HD 165141 of great value in examining the role of metallicity in barium star formation.

  3. Strontium and barium isotopes in presolar silicon carbide grains measured with CHILI-two types of X grains

    NASA Astrophysics Data System (ADS)

    Stephan, Thomas; Trappitsch, Reto; Davis, Andrew M.; Pellin, Michael J.; Rost, Detlef; Savina, Michael R.; Jadhav, Manavi; Kelly, Christopher H.; Gyngard, Frank; Hoppe, Peter; Dauphas, Nicolas

    2018-01-01

    We used CHILI, the Chicago Instrument for Laser Ionization, a new resonance ionization mass spectrometer developed for isotopic analysis of small samples, to analyze strontium, zirconium, and barium isotopes in 22 presolar silicon carbide grains. Twenty of the grains showed detectable strontium and barium, but none of the grains had enough zirconium to be detected with CHILI. Nine grains were excluded from further consideration since they showed very little signals (<1000 counts) for strontium as well as for barium. Among the 11 remaining grains, we found three X grains. The discovery of three supernova grains among only 22 grains was fortuitous, because only ∼1% of presolar silicon carbide grains are type X, but was confirmed by silicon isotopic measurements of grain residues with NanoSIMS. While one of the X grains showed strontium and barium isotope patterns expected for supernova grains, the two other supernova grains have 87Sr/86Sr < 0.5, values never observed in any natural sample before. From their silicon isotope ratios, the latter two grains can be classified as X2 grains, while the former grain belongs to the more common X1 group. The differences of these grains in strontium and barium isotopic composition constrain their individual formation conditions in Type II supernovae.

  4. Synthesis of nanostructured barium phosphate and its application in micro-computed tomography of mouse brain vessels in ex vivo

    NASA Astrophysics Data System (ADS)

    Zhu, Bangshang; Yuan, Falei; Yuan, Xiaoya; Bo, Yang; Wang, Yongting; Yang, Guo-Yuan; Drummen, Gregor P. C.; Zhu, Xinyuan

    2014-02-01

    Micro-computed tomography (micro-CT) is a powerful tool for visualizing the vascular systems of tissues, organs, or entire small animals. Vascular contrast agents play a vital role in micro-CT imaging in order to obtain clear and high-quality images. In this study, a new kind of nanostructured barium phosphate was fabricated and used as a contrast agent for ex vivo micro-CT imaging of blood vessels in the mouse brain. Nanostructured barium phosphate was synthesized through a simple wet precipitation method using Ba(NO3)2, and (NH4)2HPO4 as starting materials. The physiochemical properties of barium phosphate were characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, and thermal analysis. Furthermore, the impact of the produced nanostructures on cell viability was evaluated via the MTT assay, which generally showed low to moderate cytotoxicity. Finally, the animal test images demonstrated that the use of nanostructured barium phosphate as a contrast agent in Micro-CT imaging produced sharp images with excellent contrast. Both major vessels and the microvasculature were clearly observable in the imaged mouse brain. Overall, the results indicate that nanostructured barium phosphate is a potential and useful vascular contrast agent for micro-CT imaging.

  5. How does esophagus look on barium esophagram in pediatric eosinophilic esophagitis?

    PubMed

    Al-Hussaini, Abdulrahman; AboZeid, Amany; Hai, Abdul

    2016-08-01

    The clinical, endoscopic, and histologic findings of eosinophilic esophagitis (EoE) are well characterized; however, there have been very limited data regarding the radiologic findings of pediatric EoE. We report on the radiologic findings of pediatric EoE observed on barium esophagram and correlate them with the endoscopic findings. We identified children diagnosed with EoE in our center from 2004 to 2015. Two pediatric radiologists met after their independent evaluations of each fluoroscopic study to reach a consensus on each case. Clinical and endoscopic data were collected by retrospective chart review. Twenty-six pediatric EoE cases (age range 2-13 years; median 7.5 years) had barium esophagram done as part of the diagnostic approach for dysphagia. Thirteen children had abnormal radiologic findings of esophagus (50%): rings formation (n = 4), diffuse irregularity of mucosa (n = 8), fixed stricture formation (n = 3), and narrow-caliber esophagus (n = 10). Barium esophagram failed to show one of 10 cases of narrow-caliber esophagus and 10 of 14 cases of rings formation visualized endoscopically. The mean duration of symptoms prior to diagnosis of EoE was longer (3.7 vs. 1.7 year; p value 0.019), and the presentation with intermittent food impaction was commoner in the group with abnormal barium esophagram as compared to the group with normal barium esophagram (69% vs. 8%; p value 0.04). Barium swallow study is frequently normal in pediatric EoE. With the exception of narrow-caliber esophagus, our data show poor correlation between radiologic and endoscopic findings.

  6. Compact pulse forming line using barium titanate ceramic material

    NASA Astrophysics Data System (ADS)

    Kumar Sharma, Surender; Deb, P.; Shukla, R.; Prabaharan, T.; Shyam, A.

    2011-11-01

    Ceramic material has very high relative permittivity, so compact pulse forming line can be made using these materials. Barium titanate (BaTiO3) has a relative permittivity of 1200 so it is used for making compact pulse forming line (PFL). Barium titanate also has piezoelectric effects so it cracks during high voltages discharges due to stresses developed in it. Barium titanate is mixed with rubber which absorbs the piezoelectric stresses when the PFL is charged and regain its original shape after the discharge. A composite mixture of barium titanate with the neoprene rubber is prepared. The relative permittivity of the composite mixture is measured to be 85. A coaxial pulse forming line of inner diameter 120 mm, outer diameter 240 mm, and length 350 mm is made and the composite mixture of barium titanate and neoprene rubber is filled between the inner and outer cylinders. The PFL is charged up to 120 kV and discharged into 5 Ω load. The voltage pulse of 70 kV, 21 ns is measured across the load. The conventional PFL is made up of oil or plastics dielectrics with the relative permittivity of 2-10 [D. R. Linde, CRC Handbook of Chemistry and Physics, 90th ed. (CRC, 2009); Xia et al., Rev. Sci. Instrum. 79, 086113 (2008); Yang et al., Rev. Sci. Instrum. 81, 43303 (2010)], which increases the length of PFL. We have reported the compactness in length achieved due to increase in relative permittivity of composite mixture by adding barium titanate in neoprene rubber.

  7. Effectiveness of therapeutic barium enema for diverticular hemorrhage

    PubMed Central

    Matsuura, Mizue; Inamori, Masahiko; Nakajima, Atsushi; Komiya, Yasuhiko; Inoh, Yumi; Kawasima, Keigo; Naitoh, Mai; Fujita, Yuji; Eduka, Akiko; Kanazawa, Noriyoshi; Uchiyama, Shiori; Tani, Rie; Kawana, Kennichi; Ohtani, Setsuya; Nagase, Hajime

    2015-01-01

    AIM: To evaluate the effectiveness of barium impaction therapy for patients with colonic diverticular bleeding. METHODS: We reviewed the clinical charts of patients in whom therapeutic barium enema was performed for the control of diverticular bleeding between August 2010 and March 2012 at Yokohama Rosai Hospital. Twenty patients were included in the review, consisting of 14 men and 6 women. The median age of the patients was 73.5 years. The duration of the follow-up period ranged from 1 to 19 mo (median: 9.8 mo). Among the 20 patients were 11 patients who required the procedure for re-bleeding during hospitalization, 6 patients who required it for re-bleeding that developed after the patient left the hospital, and 3 patients who required the procedure for the prevention of re-bleeding. Barium (concentration: 150 w%/v%) was administered per the rectum, and the leading edge of the contrast medium was followed up to the cecum by fluoroscopy. After confirmation that the ascending colon and cecum were filled with barium, the enema tube was withdrawn, and the patient’s position was changed every 20 min for 3 h. RESULTS: Twelve patients remained free of re-bleeding during the follow-up period (range: 1-19 mo) after the therapeutic barium enema, including 9 men and 3 women with a median age of 72.0 years. Re-bleeding occurred in 8 patients including 5 men and 3 women with a median age of 68.5 years: 4 developed early re-bleeding, defined as re-bleeding that occurs within one week after the procedure, and the remaining 4 developed late re-bleeding. The DFI (disease-free interval) decreased 0.4 for 12 mo. Only one patient developed a complication from therapeutic barium enema (colonic perforation). CONCLUSION: Therapeutic barium enema is effective for the control of diverticular hemorrhage in cases where the active bleeding site cannot be identified by colonoscopy. PMID:25987779

  8. Urinary fluoride excretion in preschool children after intake of fluoridated milk and use of fluoride-containing toothpaste.

    PubMed

    Norman, M; Twetman, S; Hultgren Talvilahti, A; Granström, E; Stecksén-Blicks, C

    2017-03-01

    To assess the urinary fluoride excretion in preschool children after drinking fluoridated milk with 0.185 mg F and 0.375 mg F and to study the impact of use of fluoride toothpaste. Double-blind cross-over study. Nine healthy children, 2.5-4.5 years of age. In a randomized order, participants drank 1.5 dl milk once daily for 7 days with no fluoride added (control), 0.185 mg fluoride added and 0.375 mg fluoride added. The experiment was performed twice with (Part I) and without (Part II) parental tooth brushing with 1,000 ppm fluoride toothpaste. The fluoride content in the piped drinking water was 0.5 mg F/L. Urinary fluoride excretion. The 24-hour urinary fl uoride excretion/kg body weight varied from 0.014 mg F for the placebo intervention and non-fluoride toothpaste to 0.027 mg F for the 0.375 mg intervention with use of 1,000 ppm fluoride toothpaste. The difference compared with the placebo intervention was not statistically significant for any of the interventions when fluoride toothpaste was used (p⟩0.05) while it was statistically significantly different when non-fluoride toothpaste was used (p⟨0.05). All sources of fluoride must be considered when designing community programs. With 0.5 mg F/L in the drinking water and daily use of fluoride toothpaste, most children had a fluoride intake optimal for dental health. In this setting, additional intake of fluoride milk was within safe limits up to 0.185 mg/day while conclusions about the safety of 0.375 mg/day were uncertain. Copyright© 2017 Dennis Barber Ltd

  9. Determining the optimal fluoride concentration in drinking water for fluoride endemic regions in South India.

    PubMed

    Viswanathan, Gopalan; Jaswanth, A; Gopalakrishnan, S; Siva Ilango, S; Aditya, G

    2009-10-01

    Fluoride ion in drinking water is known for both beneficial and detrimental effects on health. The prevalence of fluorosis is mainly due to the intake of large quantities of fluoride through drinking water owing to more than 90% bioavailability. The objective of this study is to predict optimal fluoride level in drinking water for fluoride endemic regions by comprising the levels of fluoride and other water quality parameters in drinking water, prevalence of fluorosis, fluoride intake through water, food and beverages such as tea and coffee and also considering the progressive accumulation of fluoride in animal bones, by comparing with non fluoride endemic areas comprise of the same geological features with the aid of regression analysis. Result of this study shows that increase of fluoride level above 1.33 mg/l in drinking water increases the community fluorosis index (CFI) value more than 0.6, an optimum index value above which fluorosis is considered to be a public health problem. Regression plot between water fluoride and bone fluoride levels indicates that, every increase of 0.5mg/l unit of water fluoride level increases the bone fluoride level of 52 mg/kg unit within 2 to 3 years. Furthermore, the consumption of drinking water containing more than 0.65 mg/l of fluoride can raise the total fluoride intake per day more than 4 mg, which is the optimum fluoride dose level recommended for adults by the Agency for Toxic Substances and Disease Registry. From the result, the people in fluoride endemic areas in South India are advised to consume drinking water with fluoride level within the limit of 0.5 to 0.65 mg/l to avoid further fluorosis risk.

  10. [The dose-effect relationship of water fluoride levels and renal damage in children].

    PubMed

    Liu, Jun-Ling; Xia, Tao; Yu, Yao-Yong; Sun, Xian-Zhong; Zhu, Qilong; He, Weihong; Zhang, Ming; Wang, Aiguo

    2005-05-01

    To explore the dose-effect relationship of water fluoride levels and renal damage in children and observe the difference of renal function between high-loaded fluoride people and dental fluorosis people in the same water fluoride level region. 210 children were divided into seven groups in term of drinking water fluoride levels and whether they suffered from dental fluorosis. Fluoride concentrations in urine and serum and activities of urine NAG and gamma-GT were determined. The urine and serum fluoride of high-loaded fluoride people and dental fluorosis people increased compared with control, moreover fluoride contents in urine and serum increased gradually with the increase of fluoride level in drinking water. Urine NAG and gamma-GT activities significantly increased in dental fluorosis people from area of 2.58 mg/L fluoride in drinking water and in those two groups from area of 4.51 mg/L fluoride in drinking water. Moreover, there existed an obvious dose-effect relationship between the drinking water fluoride concentration and NAG and gamma-GT activity. Over 2.0 mg/L fluoride in drinking water can cause renal damage in children, and the damage degree increases with the drinking water fluoride content. Renal damage degree is not related to whether the children suffered from dental fluorosis and mainly due to water fluoride concentration.

  11. Urinary Fluoride Concentration in Children with Disabilities Following Long-Term Fluoride Tablet Ingestion

    ERIC Educational Resources Information Center

    Liu, Hsiu-Yueh; Chen, Jung-Ren; Hung, Hsin-Chia; Hsiao, Szu-Yu; Huang, Shun-Te; Chen, Hong-Sen

    2011-01-01

    Urine is the most commonly utilized biomarker for fluoride excretion in public health and epidemiological studies. Approximately 30-50% of fluoride is excreted from urine in children. Urinary fluoride excretion reflects the total fluoride intake from multiple sources. After administering fluoride tablets to children with disabilities, urinary…

  12. Fluoride content of tank water in Australia.

    PubMed

    Cochrane, N J; Hopcraft, M S; Tong, A C; Thean, H l; Thum, Y S; Tong, D E; Wen, J; Zhao, S C; Stanton, D P; Yuan, Y; Shen, P; Reynolds, E C

    2014-06-01

    The aims of this study were to: (1) analyse the fluoride content of tank water; (2) determine whether the method of water collection or storage influenced fluoride content; and (3) survey participant attitudes towards water fluoridation. Plastic tubes and a questionnaire were distributed through dentists to households with water tanks in Victoria. A midstream tank water sample was collected and fluoride analysed in triplicate using ion chromatography All samples (n = 123) contained negligible amounts of fluoride, with a mean fluoride concentration of <0.01 ppm (range: <0.01-0.18 ppm). No statistically significant association was found between fluoride content and variables investigated such as tank material, tank age, roof material and gutter material. Most people did not know whether their tank water contained fluoride and 40.8% preferred to have access to fluoridated water. The majority thought fluoride was safe and more than half of the respondents supported fluoridation. Fluoride content of tank water was well below the optimal levels for caries prevention. People who rely solely on tank water for drinking may require additional exposure to fluoride for optimal caries prevention. © 2014 Australian Dental Association.

  13. Kinetics of fluoride bioavailability in supernatant saliva and salivary sediment.

    PubMed

    Naumova, E A; Sandulescu, T; Bochnig, C; Gaengler, P; Zimmer, S; Arnold, W H

    2012-07-01

    The assessment of the fluoride kinetics in whole saliva as well as in the different salivary phases (supernatant saliva and sediment) is essential for the understanding of fluoride bioavailability. To assess the fluoride content, provided by sodium fluoride and amine fluoride, in the supernatant saliva and in salivary sediment. Seven trained volunteers were randomly attributed to 2 groups in a cross-over design and brushed their teeth in the morning for 3 min with a product containing either sodium fluoride or amine fluoride. Saliva was collected before, immediately after tooth brushing and 30, 120, and 360 min later and measured. The samples were centrifuged 10 min at 3024 × g. Fluoride content of the supernatant saliva and of the sediment was analysed using a fluoride sensitive electrode. All subjects repeated the study cycles 2 times, and statistical analyses were made using the nonparametric sign test for related samples, the Wilcoxon-Mann-Whitney-test for independent samples. There was a significant increase in fluoride immediately after tooth brushing in both groups in saliva and sediment. The distribution of fluoride between salivary sediment and supernatant saliva (ratio) varied considerably at the different collection times: decreased from 17.87 in baseline samples of saliva to 0.07 immediately and to 0.86 half an hour after tooth brushing in the sodium fluoride group and from 14.33 to 2.85 and to 3.09 in the amine fluoride group. Furthermore after 120 min and after 360 min after tooth brushing the ratio increased from 17.6 to 31.6 in the sodium fluoride group and from 20.5 to 25.76 in the amine fluoride group. No difference was found in the sediment-supernatant saliva ratio between the sodium fluoride and the amine fluoride groups 360 min after tooth brushing. For the assessment of fluoride kinetics in whole saliva it is necessary to pay attention to at least four factors: fluoride formulation, time after fluoride application, fluoride concentration in supernatant saliva and fluoride concentration in salivary sediment. This study was approved by the Ethical Committee of the University of Witten/Herdecke permission 21/2008. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Iodine-126 1 Iodine-129 0.1 Iodine-131 1 Iodine-132 10 Iodine-133 1 Iodine-134 10 Iodine-135 10 Iridium... Arsenic-73 100 Arsenic-74 10 Arsenic-76 10 Arsenic-77 100 Barium-131 10 Barium-133 10 Barium-140 10... Carbon-14 100 Cerium-141 100 Cerium-143 100 Cerium-144 1 Cesium-131 1,000 Cesium-134m 100 Cesium-134 1...

  15. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Iodine-126 1 Iodine-129 0.1 Iodine-131 1 Iodine-132 10 Iodine-133 1 Iodine-134 10 Iodine-135 10 Iridium... Arsenic-73 100 Arsenic-74 10 Arsenic-76 10 Arsenic-77 100 Barium-131 10 Barium-133 10 Barium-140 10... Carbon-14 100 Cerium-141 100 Cerium-143 100 Cerium-144 1 Cesium-131 1,000 Cesium-134m 100 Cesium-134 1...

  16. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Iodine-126 1 Iodine-129 0.1 Iodine-131 1 Iodine-132 10 Iodine-133 1 Iodine-134 10 Iodine-135 10 Iridium... Arsenic-73 100 Arsenic-74 10 Arsenic-76 10 Arsenic-77 100 Barium-131 10 Barium-133 10 Barium-140 10... Carbon-14 100 Cerium-141 100 Cerium-143 100 Cerium-144 1 Cesium-131 1,000 Cesium-134m 100 Cesium-134 1...

  17. Barium isotope fractionation during experimental formation of the double carbonate BaMn[CO3](2) at ambient temperature.

    PubMed

    Böttcher, Michael E; Geprägs, Patrizia; Neubert, Nadja; von Allmen, Katja; Pretet, Chloé; Samankassou, Elias; Nägler, Thomas F

    2012-09-01

    In this study, we present the first experimental results for stable barium (Ba) isotope ((137)Ba/(134)Ba) fractionation during low-temperature formation of the anhydrous double carbonate BaMn[CO(3)](2). This investigation is part of an ongoing work on Ba fractionation in the natural barium cycle. Precipitation at a temperature of 21±1°C leads to an enrichment of the lighter Ba isotope described by an enrichment factor of-0.11±0.06‰ in the double carbonate than in an aqueous barium-manganese(II) chloride/sodium bicarbonate solution, which is within the range of previous reports for synthetic pure BaCO (3) (witherite) formation.

  18. Interpretation and modelling of fission product Ba and Mo releases from fuel

    NASA Astrophysics Data System (ADS)

    Brillant, G.

    2010-02-01

    The release mechanisms of two fission products (namely barium and molybdenum) in severe accident conditions are studied using the VERCORS experimental observations. Barium is observed to be mostly released under reducing conditions while molybdenum release is most observed under oxidizing conditions. As well, the volatility of some precipitates in fuel is evaluated by thermodynamic equilibrium calculations. The polymeric species (MoO 3) n are calculated to largely contribute to molybdenum partial pressure and barium volatility is greatly enhanced if the gas atmosphere is reducing. Analytical models of fission product release from fuel are proposed for barium and molybdenum. Finally, these models have been integrated in the ASTEC/ELSA code and validation calculations have been performed on several experimental tests.

  19. Th/U/Pu/Cm dating of galactic cosmic rays with the extremely heavy cosmic ray composition observer

    NASA Astrophysics Data System (ADS)

    Westphal, Andrew J.; Weaver, Benjamin A.; Tarlé, Gregory

    The principal goal of ECCO, the Extremely-heavy Cosmic-ray Composition Observer, is the measurement of the age of heavy galactic cosmic-ray nuclei using the extremely rare actinides (Th, U, Pu, Cm) as clocks. ECCO is one of two cosmic-ray instruments comprising the Heavy Nuclei Explorer (HNX), which was recently selected as one of several missions for Phase A study under NASA's Small class Explorer (SMEX) program. ECCO is based on the flight heritage of Trek, an array of barium-phosphate glass tracketch detectors deployed on the Russian space station Mir from 1991-1995. Using Trek, we measured the abundances of elements with Z > 70 in the galactic cosmic rays (GCRs). Trek consisted of a 1 m 2 array of stacks of individually polished thin BP-1 glass detectors. ECCO will be a much larger instrument, but will achieve both excellent resolution and low cost through use of a novel detector configuration. Here we report the results of recent accelerator tests of the ECCO detectors that verify detector performance. We also show the expected charge and energy resolution of ECCO as a function of energy.

  20. Focus on Fluorides: Update on the Use of Fluoride for the Prevention of Dental Caries

    PubMed Central

    Carey, Clifton M.

    2014-01-01

    Declarative Title: Improving the efficacy of fluoride therapies reduces dental caries and lowers fluoride exposure. Background Fluoride is delivered to the teeth systemically or topically to aid in the prevention of dental caries. Systemic fluoride from ingested sources is in blood serum and can be deposited only in teeth that are forming in children. Topical fluoride is from sources such as community water, processed foods, beverages, toothpastes, mouthrinses, gels, foams, and varnishes. The United States Centers for Disease Control and Prevention (CDC) and the American Dental Association (ADA) have proposed changes in their long standing recommendations for the amount of fluoride in community drinking water in response to concerns about an increasing incidence of dental fluorosis in children. Current research is focused on the development of strategies to improve fluoride efficacy. The purpose of this update is to inform the reader about new research and policies related to the use of fluoride for the prevention of dental caries. Methods Reviews of the current research and recent evidence based systematic reviews on the topics of fluoride are presented. Topics discussed include: updates on community water fluoridation research and policies; available fluoride in dentifrices; fluoride varnish compositions, use, and recommendations; and other fluoride containing dental products. This update provides insights into current research and discusses proposed policy changes for the use of fluoride for the prevention of dental caries. Conclusions The dental profession is adjusting their recommendations for fluoride use based on current observations of the halo effect and subsequent outcomes. The research community is focused on improving the efficacy of fluoride therapies thus reducing dental caries and lowering the amount of fluoride required for efficacy. PMID:24929594

  1. Focus on fluorides: update on the use of fluoride for the prevention of dental caries.

    PubMed

    Carey, Clifton M

    2014-06-01

    Improving the efficacy of fluoride therapies reduces dental caries and lowers fluoride exposure. Fluoride is delivered to the teeth systemically or topically to aid in the prevention of dental caries. Systemic fluoride from ingested sources is in blood serum and can be deposited only in teeth that are forming in children. Topical fluoride is from sources such as community water, processed foods, beverages, toothpastes, mouthrinses, gels, foams, and varnishes. The United States Centers for Disease Control and Prevention (CDC) and the American Dental Association (ADA) have proposed changes in their long standing recommendations for the amount of fluoride in community drinking water in response to concerns about an increasing incidence of dental fluorosis in children. Current research is focused on the development of strategies to improve fluoride efficacy. The purpose of this update is to inform the reader about new research and policies related to the use of fluoride for the prevention of dental caries. Reviews of the current research and recent evidence based systematic reviews on the topics of fluoride are presented. Topics discussed include: updates on community water fluoridation research and policies; available fluoride in dentifrices; fluoride varnish compositions, use, and recommendations; and other fluoride containing dental products. This update provides insights into current research and discusses proposed policy changes for the use of fluoride for the prevention of dental caries. The dental profession is adjusting their recommendations for fluoride use based on current observations of the halo effect and subsequent outcomes. The research community is focused on improving the efficacy of fluoride therapies thus reducing dental caries and lowering the amount of fluoride required for efficacy. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. The cariostatic mechanisms of fluoride.

    PubMed

    Rošin-Grget, Kata; Peroš, Kristina; Sutej, Ivana; Bašić, Krešimir

    2013-11-01

    This article discusses the possible cariostatic mechanisms of the action of fluoride. In the past, fluoride inhibition of caries was ascribed to reduced solubility of enamel due to incorporation of fluoride (F-) into the enamel minerals. The present evidence from clinical and laboratory studies suggests that the caries-preventive mode of action of fluoride is mainly topical. There is convincing evidence that fluoride has a major effect on demineralisation and remineralisation of dental hard tissue. The source of this fluoride could either be fluorapatite (formed due to the incorporation of fluoride into enamel) or calcium fluoride (CaF2)-like precipitates, which are formed on the enamel and in the plaque after application of topical fluoride. Calcium fluoride deposits are protected from rapid dissolution by a phosphate -protein coating of salivary origin. At lower pH, the coating is lost and an increased dissolution rate of calcium fluoride occurs. The CaF2, therefore, act as an efficient source of free fluoride ions during the cariogenic challenge. The current evidence indicates that fluoride has a direct and indirect effect on bacterial cells, although the in vivo implications of this are still not clear. A better understanding of the mechanisms of the action of fluoride is very important for caries prevention and control. The effectiveness of fluoride as a cariostatic agent depends on the availability of free fluoride in plaque during cariogenic challenge, i.e. during acid production. Thus, a constant supply of low levels of fluoride in biofilm/saliva/dental interference is considered the most beneficial in preventing dental caries. Copyright © 2013 by Academy of Sciences and Arts of Bosnia and Herzegovina.

  3. Fluoride Supplementation Adherence and Barriers in a Community Without Water Fluoridation.

    PubMed

    Flood, Shannon; Asplund, Karin; Hoffman, Benjamin; Nye, Allison; Zuckerman, Katharine E

    2017-04-01

    To prevent early childhood caries, the American Dental Association recommends oral fluoride supplementation for children in communities lacking water fluoridation who are at high caries risk. However, patient adherence to oral fluoride supplementation has not been studied in this population. This study assessed adherence to oral fluoride and barriers to adherence in a community lacking water fluoridation. A self-administered survey was completed in a systematic sample of 209 parents of children aged 6 months to 4 years, during a primary care visit in an urban academic medical center. Participants reported frequency of administering oral fluoride to their children, as well as agreement or disagreement with proposed barriers to supplementation. Bivariate and multivariate analyses were used to assess adherence with oral supplementation and the association of barriers to supplementation and child receipt of fluoride on the day before. More than half of parents either had not or did not know if their child had received fluoride on the day before. Approximately 1 in 4 of parents had given fluoride in 0 of the previous 7 days. Difficulty remembering to give fluoride and agreeing that the child does not need extra fluoride were associated with not receiving fluoride on the day before. Adherence to oral fluoride supplementation in the primary care setting is low. Difficulty remembering to give fluoride daily is the greatest barrier to adherence. Further research on interventions to reduce common barriers is needed to increase fluoride administration and reduce early childhood caries in communities lacking water fluoridation. Copyright © 2016 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  4. Lanthanide doped strontium-barium cesium halide scintillators

    DOEpatents

    Bizarri, Gregory; Bourret-Courchesne, Edith; Derenzo, Stephen E.; Borade, Ramesh B.; Gundiah, Gautam; Yan, Zewu; Hanrahan, Stephen M.; Chaudhry, Anurag; Canning, Andrew

    2015-06-09

    The present invention provides for a composition comprising an inorganic scintillator comprising an optionally lanthanide-doped strontium-barium, optionally cesium, halide, useful for detecting nuclear material.

  5. Investigation on nanoscale processes on the BaF{sub 2}(111) surface in various solutions by frequency modulation atomic force microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kobayashi, Naritaka, E-mail: naritaka@mail.saitama-u.ac.jp; Kawamura, Ryuzo; Yoshikawa, Hiroshi Y.

    2016-06-07

    In this study, we have directly observed nanoscale processes that occur on BaF{sub 2}(111) surfaces in various solutions using liquid-environment frequency modulation atomic force microscopy (FM-AFM) with a true atomic resolution. In addition, to investigate atomic-scale mechanisms of crystal growth process of BaF{sub 2}, we determined a suitable solution for atomic-resolution FM-AFM imaging of the BaF{sub 2}(111) surface. For undersaturated solutions, the surface is roughened by barium hydroxo complexes in the case of high pH, whereas by dissolution and proton or water molecule adsorption throughout the surface in the case of low pH. On the other hand, for supersaturated solutions,more » the surface shows two-dimensional nucleation and growth (σ = 0.1) and three-dimensional crystal growth with tetrahedral structures (σ = 1), where σ is the degree of supersaturation. The atomic-resolution imaging of the BaF{sub 2}(111) surface has been demonstrated in potassium fluoride (KF) and the supersaturated (σ = 0.1 and 1) solutions, wherein atomically flat terraces are shown at least for about 30 min.« less

  6. Irradiation effect on luminescence properties of fluoroperovskite single crystal (LiBaF3:Eu2+)

    NASA Astrophysics Data System (ADS)

    Daniel, D. Joseph; Madhusoodanan, U.; Nithya, R.; Ramasamy, P.

    2014-03-01

    Single crystals of pure and Eu2+ doped LiBaF3 have been grown from melt by using a vertical Bridgman-Stockbarger method. Effects induced by irradiation on europium doped LiBaF3 (lithium barium fluoride) single crystals were monitored by optical absorption, photoluminescence and thermoluminescence studies. The absorption bands of Eu2+ ions with peaks at 240, 290 and 320 nm were observed in the LiBaF3:Eu2+ crystal. Drastic increase in absorption was noted below 600 nm after gamma irradiation, which was dependent on the radiation dose. The additional absorption peak at around 570 nm was observed in irradiated crystal due to the ionization process Eu2+(-)e-→Eu3+. Photoluminescence of Eu2+ doped LiBaF3 single crystal shows sharp line peaked at ~359 nm and a broad band extending between 370 and 450 nm which shows a considerable reduction in Eu2+ PL intensity after gamma irradiation. Irradiated LiBaF3:Eu2+ sample has revealed three intense TL glow peaks at 128 °C (peak-1), 281 °C (peak-2) and 407 °C (peak-3). Activation energy (E) and frequency factor (s) of the latter two peaks were determined by various heating rate (VHR) method and graphical method.

  7. Groundwater quality in the Delaware and St. Lawrence River Basins, New York, 2010

    USGS Publications Warehouse

    Nystrom, Elizabeth A.

    2012-01-01

    Water quality in both study areas is generally good, but concentrations of some constituents equaled or exceeded current or proposed Federal or New York State drinking-water standards. The standards exceeded are color (one sample in the St. Lawrence study area), pH (three samples in the Delaware study area), sodium (one sample in the St. Lawrence study area), total dissolved solids (one sample in the St. Lawrence study area), aluminum (one sample in the Delaware study area and one sample in the St. Lawrence study area), iron (seven samples in the St. Lawrence study area), manganese (one sample in the Delaware study area and five samples in the St. Lawrence study area), gross alpha radioactivity (one sample in the St. Lawrence study area), radon-222 (10 samples in the Delaware study area and 14 samples in the St. Lawrence study area), and bacteria (5 samples in the Delaware study area and 10 samples in the St. Lawrence study area). E. coli bacteria were detected in samples from two wells in the St. Lawrence study area. Concentrations of chloride, fluoride, sulfate, nitrate, nitrite, antimony, arsenic, barium, beryllium, cadmium, chromium, copper, lead, mercury, selenium, silver, thallium, zinc, and uranium did not exceed existing drinking-water standards in any of the samples collected.

  8. Oral fluoride levels 1 h after use of a sodium fluoride rinse: effect of sodium lauryl sulfate.

    PubMed

    Vogel, Gerald L; Schumacher, Gary E; Chow, Laurence C; Tenuta, Livia M A

    2015-01-01

    Increasing the concentration of free fluoride in oral fluids is an important goal in the use of topical fluoride agents. Although sodium lauryl sulfate (SLS) is a common dentifrice ingredient, the influence of this ion on plaque fluid and salivary fluid fluoride has not been examined. The purpose of this study was to investigate the effect of SLS on these parameters and to examine the effect of this ion on total (or whole) plaque fluoride, an important source of plaque fluid fluoride after a sufficient interval following fluoride administration, and on total salivary fluoride, a parameter often used as a surrogate measure of salivary fluid fluoride. Ten subjects accumulated plaque for 48 h before rinsing with a 12 mmol/l NaF (228 µg/g F) rinse containing or not containing 0.5% (w/w) SLS. SLS had no statistically significant effect on total plaque and total saliva fluoride but significantly increased salivary fluid and plaque fluid fluoride (by 147 and 205%, respectively). These results suggest that the nonfluoride components of topical agents can be manipulated to improve the fluoride release characteristics from oral fluoride reservoirs and that statistically significant change may be observed in plaque fluid and salivary fluid fluoride concentrations that may not be observed in total plaque and total saliva fluoride concentrations.

  9. The effect of fluoridation and its discontinuation on fluoride profiles in the alveolar bone of rat.

    PubMed

    Ohmi, Kyohei; Nakagaki, Haruo; Tsuboi, Shinji; Okumura, Akihiro; Sugiyama, Tomoko; Thuy, Tran Thu; Robinson, Colin

    2005-10-01

    We investigated the effect of fluoridation and its discontinuation on fluoride content in the alveolar portion of the mandible in rats. Drinking water with three different fluoride contents (0, 50, 100 ppmF) was given to rats for three different periods (4, 13 and 25 weeks). Fluoride concentrations were measured in the crest, the middle, and the apical parts of the alveolar bone and in the body of the mandible. Furthermore, after fluoridated drinking water was given to rats for 4 or 13 weeks, distilled water was given to them for 21 or 12 weeks respectively; and the effect of the discontinuation on fluoride profiles was investigated. Layer samples were analyzed by abrasive microsampling. Fluoride and phosphorus concentrations were determined by ion-specific electrode and colorimetric procedures, respectively. There was an increase in fluoride concentrations in the mandible in proportion to the fluoride content in the drinking water and the duration of fluoridation. After fluoridation was discontinued, fluoride concentrations in the surface layers of the mandible presented a decrease. Among the four different parts of the mandible, the upper part of the alveolar bone and the alveolar crest part presented the highest rates of reduction. The relative reduction rate of fluoride concentration was closely related to the duration of discontinuation. The alveolar crest was affected most by the discontinuation of fluoridation, presenting the greatest reduction.

  10. Determination of barium in natural waters by ICP-OES technique. Part II: Assessment of human exposure to barium in bottled mineral and spring waters produced in Poland.

    PubMed

    Garboś, Sławomir; Swiecicka, Dorota

    2013-01-01

    A method of the classification of natural mineral and spring waters and maximum admissible concentration (MAC) levels of metals present in such types of waters are regulated by Commission Directive 2003/40/EC, Directive 2009/54/EC of the European Parliament and of the Council and Ordinance of Minister of Health of 30 March 2011 on the natural mineral waters, spring waters and potable waters. MAC of barium in natural mineral and spring waters was set at 1.0 mg/l, while World Health Organization determined the Ba guideline value in water intended for human consumption at the level of 0.7 mg/l. The aims of the study were: the determination of barium in natural mineral and spring waters (carbonated, non-carbonated and medium-carbonated waters) produced and bottled on the area of Poland, and assessment of human exposure to this metal presents in the above-mentioned types of waters. The study concerning barium determinations in 23 types of bottled natural mineral waters and 15 types of bottled spring waters (bought in Polish retail outlets) was conducted in 2010. The analyses were performed by validated method of determination of barium in water based on inductively coupled plasma optical emission spectrometry, using modern internal quality control scheme. Concentrations of barium determined in natural mineral and spring waters were in the ranges from 0.0136 mg/l to 1.12 mg/l and from 0.0044 mg/l to 0.43 mg/l, respectively. Only in the single case of natural mineral water the concentration of barium (1.12 mg/l), exceeded above-mentioned MAC for this metal, which is obligatory in Poland and the European Union - 1.0 mg/l. The long-term monitoring of barium concentration in another natural mineral water (2006 - 2010), in which incidental exceeding MAC was observed in 2006, was conducted. All measured barium concentrations in this water were lower than 1.0 mg/l and therefore, it is possible to state that the proper method of mixing waters taken from six independent groundwater intakes applied during production is actually used. The estimated Hazard Quotient indices were in the ranges: 0.0019 - 0.16 (natural mineral waters) and 0.00063 - 0.061 (natural spring waters), respectively. The natural mineral waters are usually characterized by higher Ba concentrations than those observed in the cases of natural spring waters. The presence of a high concentration of HCO3- in such types of natural waters ensures the existence of Ba2+ in solution as Ba(HCO3)2, which is a highly soluble salt. Taking into account the concentrations of barium determined in above-mentioned waters and the available toxicological data for this metal no long-term risk for human health could be expected (estimated Hazard Quotient indices < or = 0.16).

  11. Efficacy of Barium-Based Fecal Tagging for CT Colonography: a Comparison between the Use of High and Low Density Barium Suspensions in a Korean Population - a Preliminary Study

    PubMed Central

    Kim, Min Ju; Lee, Seung Soo; Byeon, Jeong-Sik; Choi, Eugene K.; Kim, Jung Hoon; Kim, Yeoung Nam; Kim, Ah Young; Ha, Hyun Kwon

    2009-01-01

    Objective This preliminarily study was designed to determine and to compare the efficacy of two commercially available barium-based fecal tagging agents for CT colonography (CTC) (high-density [40% w/v] and low-density [4.6% w/v] barium suspensions) in a population in Korea. Materials and Methods In a population with an identified with an average-risk for colorectal cancer, 15 adults were administered three doses of 20 ml 40% w/v barium for fecal tagging (group I) and 15 adults were administered three doses of 200 ml 4.6% w/v barium (group II) for fecal tagging. Excluding five patients in group I and one patient in group II that left the study, ten patients in group I and 14 patients in group II were finally included in the analysis. Two experienced readers evaluated the CTC images in consensus regarding the degree of tagging of stool pieces 6 mm or larger. Stool pieces were confirmed with the use of standardized CTC criteria or the absence of matched lesions as seen on colonoscopy. The rates of complete fecal tagging were analyzed on a per-lesion and a per-segment basis and were compared between the patients in the two groups. Results Per-lesion rates of complete fecal tagging were 52% (22 of 42; 95% CI, 37.7-66.6%) in group I and 78% (28 of 36; 95% CI, 61.7-88.5%) in group II. The difference between the two groups did not reach statistical significance (p = 0.285). The per-segment rates of complete tagging were 33% (6 of 18; 95% CI, 16.1%-56.4%) in group I and 60% (9 of 15; 95% CI, 35.7%-80.3%) in group II; again, the difference between the two groups did not reach statistical significance (p = 0.171). Conclusion Barium-based fecal tagging using both the 40% w/v and the 4.6% w/v barium suspensions showed moderate tagging efficacy. The preliminary comparison did not demonstrate a statistically significant difference in the tagging efficacy between the use of the two tagging agents, despite the tendency toward better tagging with the use of the 4.6% w/v barium suspension. PMID:19182500

  12. Fluoride barriers in Nb/Pb Josephson junctions

    NASA Astrophysics Data System (ADS)

    Asano, H.; Tanabe, K.; Michikami, O.; Igarashi, M.; Beasley, M. R.

    1985-03-01

    Josephson tunnel junctions are fabricated using a new class of artificial barriers, metal fluorides (Al fluoride and Zr fluoride). These fluoride barriers are deposited on the surface of a Nb base electrode, which are previously cleaned using a CF4 cleaning process, and covered by a Pb counterelectrode. The junctions with both Al fluoride and Zr fluoride barriers exhibit good tunneling characteristics and have low specific capacitance. In the case of Zr fluoride, it is observed that reasonable resistances are obtained even at thickness greater than 100 A. This phenomenon might be explained by tunneling via localized states in Zr fluoride.

  13. Eukaryotic resistance to fluoride toxicity mediated by a widespread family of fluoride export proteins.

    PubMed

    Li, Sanshu; Smith, Kathryn D; Davis, Jared H; Gordon, Patricia B; Breaker, Ronald R; Strobel, Scott A

    2013-11-19

    Fluorine is an abundant element and is toxic to organisms from bacteria to humans, but the mechanisms by which eukaryotes resist fluoride toxicity are unknown. The Escherichia coli gene crcB was recently shown to be regulated by a fluoride-responsive riboswitch, implicating it in fluoride response. There are >8,000 crcB homologs across all domains of life, indicating that it has an important role in biology. Here we demonstrate that eukaryotic homologs [renamed FEX (fluoride exporter)] function in fluoride export. FEX KOs in three eukaryotic model organisms, Neurospora crassa, Saccharomyces cerevisiae, and Candida albicans, are highly sensitized to fluoride (>200-fold) but not to other halides. Some of these KO strains are unable to grow in fluoride concentrations found in tap water. Using the radioactive isotope of fluoride, (18)F, we developed an assay to measure the intracellular fluoride concentration and show that the FEX deletion strains accumulate fluoride in excess of the external concentration, providing direct evidence of FEX function in fluoride efflux. In addition, they are more sensitive to lower pH in the presence of fluoride. These results demonstrate that eukaryotic FEX genes encode a previously unrecognized class of fluoride exporter necessary for survival in standard environmental conditions.

  14. Eukaryotic resistance to fluoride toxicity mediated by a widespread family of fluoride export proteins

    PubMed Central

    Li, Sanshu; Smith, Kathryn D.; Davis, Jared H.; Gordon, Patricia B.; Breaker, Ronald R.; Strobel, Scott A.

    2013-01-01

    Fluorine is an abundant element and is toxic to organisms from bacteria to humans, but the mechanisms by which eukaryotes resist fluoride toxicity are unknown. The Escherichia coli gene crcB was recently shown to be regulated by a fluoride-responsive riboswitch, implicating it in fluoride response. There are >8,000 crcB homologs across all domains of life, indicating that it has an important role in biology. Here we demonstrate that eukaryotic homologs [renamed FEX (fluoride exporter)] function in fluoride export. FEX KOs in three eukaryotic model organisms, Neurospora crassa, Saccharomyces cerevisiae, and Candida albicans, are highly sensitized to fluoride (>200-fold) but not to other halides. Some of these KO strains are unable to grow in fluoride concentrations found in tap water. Using the radioactive isotope of fluoride, 18F, we developed an assay to measure the intracellular fluoride concentration and show that the FEX deletion strains accumulate fluoride in excess of the external concentration, providing direct evidence of FEX function in fluoride efflux. In addition, they are more sensitive to lower pH in the presence of fluoride. These results demonstrate that eukaryotic FEX genes encode a previously unrecognized class of fluoride exporter necessary for survival in standard environmental conditions. PMID:24173035

  15. Enhanced piezoresponse of highly aligned electrospun poly(vinylidene fluoride) nanofibers

    NASA Astrophysics Data System (ADS)

    Kang, Sung Bum; Won, Sang Hyuk; Im, Min Ji; Kim, Chan Ul; Park, Won Il; Baik, Jeong Min; Choi, Kyoung Jin

    2017-09-01

    Well-ordered nanostructure arrays with controlled densities can potentially improve material properties; however, their fabrication typically involves the use of complicated processing techniques. In this work, we demonstrate a uniaxial alignment procedure for fabricating poly(vinylidene fluoride) (PVDF) electrospun nanofibers (NFs) by introducing collectors with additional steps. The mechanism of the observed NF alignment, which occurs due to the concentration of lateral electric field lines around collector steps, has been elucidated via finite-difference time-domain simulations. The membranes composed of well-aligned PVDF NFs are characterized by a higher content of the PVDF β-phase, as compared to those manufactured from randomly orientated fibers. The piezoelectric energy harvester, which was fabricated by transferring well-aligned PVDF NFs onto flexible substrates with Ag electrodes attached to both sides, exhibited a 2-fold increase in the output voltage and a 3-fold increase in the output current as compared to the corresponding values obtained for the device manufactured from randomly oriented NFs. The enhanced piezoresponse observed for the aligned PVDF NFs is due to their higher β-phase content, denser structure, smaller effective radius of curvature during bending, greater applied strain, and higher fraction of contributing NFs.

  16. Indium Tin Oxide-Magnesium Fluoride Co-Deposited Films for Spacecraft Applications

    NASA Technical Reports Server (NTRS)

    Dever, Joycer A.; Rutledge, Sharon K.; Hambourger, Paul D.; Bruckner, Eric; Ferrante, Rhea; Pal, Anna Marie; Mayer, Karen; Pietromica, Anthony J.

    1998-01-01

    Highly transparent coatings with a maximum sheet resistivity between 10(exp 8) and 10(exp 9) ohms/square are desired to prevent charging of solar arrays for low Earth polar orbit and geosynchronous orbit missions. Indium tin oxide (ITO) and magnesium fluoride (MgF2) were ion beam sputter co-deposited onto fused silica substrates and were evaluated for transmittance, sheet resistivity and the effects of simulated space environments including atomic oxygen (AO) and vacuum ultraviolet (VUV) radiation. Optical properties and sheet resistivity as a function of MgF2 content in the films will be presented. Films containing 8.4 wt.% MgF2 were found to be highly transparent and provided sheet resistivity in the required range. These films maintained a high transmittance upon exposure to AO and to VUV radiation, although exposure to AO in the presence of charged species and intense electromagnetic radiation caused significant degradation in film transmittance. Sheet resistivity of the as-fabricated films increased with time in ambient conditions. Vacuum beat treatment following film deposition caused a reduction in sheet resistivity. However, following vacuum heat treatment, sheet resistivity values remained stable during storage in ambient conditions.

  17. Fluoride metabolism when added to salt.

    PubMed

    Whitford, Gary M

    2005-01-01

    The purpose of this review is to present the general characteristics of the metabolism of fluoride particularly as it occurs when ingested with fluoridated salt. Following the absorption of salt-borne fluoride from the stomach and intestines, its metabolism is identical to that of water-borne fluoride or other vehicles containing ionized fluoride. Because fluoridated salt is almost always ingested with food, however, absorption from the gastrointestinal tract may be delayed or reduced. Reports dealing with this subject have shown that fluoride absorption is delayed and, therefore, peak plasma concentrations are lower than when fluoride is ingested with water. The amount of ingested fluoride that is finally absorbed, however, is not appreciably affected unless the meal is composed mainly of components with high calcium concentrations. In this case, the extent of absorption can be reduced by as much as 50%. Fluoridated salt is also ingested less frequently than fluoridated water. Data are presented to show that the dose size and frequency of ingestion have only minor effects on fluoride retention in the body and on the concentrations in plasma, bone and enamel. Finally, calculations are presented to show that the risk of acute toxicity from fluoridated salt is virtually non-existent.

  18. Fluoride content of still bottled water in Australia.

    PubMed

    Cochrane, N J; Saranathan, S; Morgan, M V; Dashper, S G

    2006-09-01

    Recently there has been a considerable increase in the consumption of bottled water in Australia. Overseas studies have found the fluoride levels in many bottled waters are well below levels considered optimal for preventing dental caries. This raises the concern that if bottled water is regularly consumed an effective means of preventing dental caries is unavailable. The aim of this study was to determine the fluoride concentration in 10 popular brands of still bottled water currently sold in Australia. The fluoride content of water samples were determined using an ion analyser and compared to a fluoride standard. The fluoride concentration of all bottled waters was less than 0.08 ppm. Only three of the 10 brands indicated the fluoride content on their labels. Melbourne reticulated water was found to be fluoridated at 1.02 ppm. All bottled waters tested contained negligible fluoride which justifies the concern that regular consumption of bottled water may reduce the benefits gained from water fluoridation. It is recommended that all bottled water companies should consider stating their fluoride content on their labels. This will inform consumers and dental care providers of the levels of fluoride in bottled water and allow an informed decision regarding consumption of fluoridated versus non-fluoridated drinking water.

  19. Initial Investigation of Factors Influencing Radiation Dose to Patients Undergoing Barium-Based Fluoroscopy Procedures in Tanzania.

    PubMed

    Ngaile, J E; Msaki, P K; Kazema, R R; Schreiner, L J

    2017-04-25

    The aim of this study was to investigate the nature and causes of radiation dose imparted to patients undergoing barium-based X-ray fluoroscopy procedures in Tanzania and to compare these doses to those reported in the literature from other regions worldwide. The air kerma area product (KAP) to patient undergoing barium investigations of gastrointestinal tract system was obtained from four consultant hospitals. The KAP was determined using a flat transparent transmission ionization chamber. Mean values of KAP for barium swallow (BS), barium meal (BM) and barium enema (BE) were 2.79, 2.62 and 15.04 Gy cm2, respectively. The mean values of KAP per hospital for the BS, BM and BE procedures varied by factors of up to 7.3, 1.6 and 2.0, respectively. The overall difference between individual patient doses across the four consultant hospitals investigated differed by factors of up to 53, 29.5 and 12 for the BS, BM and BE procedures, respectively. The majority of the mean values of KAP was lower than the reported values for Ghana, Greece, Spain and the UK, while slightly higher than those reported for India. The observed wide variation of KAP values for the same fluoroscopy procedure within and among the hospitals was largely attributed to the dynamic nature of the procedures, the patient characteristics, the skills and experience of personnel, and the different examination protocols employed among hospitals. The observed great variations of procedural protocols and patient doses within and across the hospitals call for the need to standardize examination protocols and optimize barium-based fluoroscopy procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Individual-specific transgenerational marking of fish populations based on a barium dual-isotope procedure.

    PubMed

    Huelga-Suarez, Gonzalo; Moldovan, Mariella; Garcia-Valiente, America; Garcia-Vazquez, Eva; Alonso, J Ignacio Garcia

    2012-01-03

    The present study focuses on the development and evaluation of an individual-specific transgenerational marking procedure using two enriched barium isotopes, (135)Ba and (137)Ba, mixed at a given and selectable molar ratio. The method is based on the deconvolution of the isotope patterns found in the sample into four molar contribution factors: natural xenon (Xe nat), natural barium (Ba nat), Ba135, and Ba137. The ratio of molar contributions between Ba137 and Ba135 is constant and independent of the contribution of natural barium in the sample. This procedure was tested in brown trout ( Salmo trutta ) kept in captivity. Trout were injected with three different Ba137/Ba135 isotopic signatures ca. 7 months and 7 days before spawning to compare the efficiency of the marking procedure at long and short term, respectively. The barium isotopic profiles were measured in the offspring by means of inductively coupled plasma mass spectrometry. Each of the three different isotopic signatures was unequivocally identified in the offspring in both whole eggs and larvae. For 9 month old offspring, the characteristic barium isotope signatures could also be detected in the otoliths even in the presence of a high and variable amount of barium of natural isotope abundance. In conclusion, it can be stated that the proposed dual-isotope marking is inheritable and can be detected after both long-term and short-term marking. Furthermore, the dual-isotope marking can be made individual-specific, so that it allows identification of offspring from a single individual or a group of individuals within a given fish group. © 2011 American Chemical Society

  1. Biodistribution of strontium and barium in the developing and mature skeleton of rats.

    PubMed

    Panahifar, Arash; Chapman, L Dean; Weber, Lynn; Samadi, Nazanin; Cooper, David M L

    2018-06-19

    Bone acts as a reservoir for many trace elements. Understanding the extent and pattern of elemental accumulation in the skeleton is important from diagnostic, therapeutic, and toxicological perspectives. Some elements are simply adsorbed to bone surfaces by electric force and are buried under bone mineral, while others can replace calcium atoms in the hydroxyapatite structure. In this article, we investigated the extent and pattern of skeletal uptake of barium and strontium in two different age groups, growing, and skeletally mature, in healthy rats. Animals were dosed orally for 4 weeks with either strontium chloride or barium chloride or combined. The distribution of trace elements was imaged in 3D using synchrotron K-edge subtraction micro-CT at 13.5 µm resolution and 2D electron probe microanalysis (EPMA). Bulk concentration of the elements in serum and bone (tibiae) was also measured by mass spectrometry to study the extent of uptake. Toxicological evaluation did not show any cardiotoxicity or nephrotoxicity. Both elements were primarily deposited in the areas of active bone turnover such as growth plates and trabecular bone. Barium and strontium concentration in the bones of juvenile rats was 2.3 times higher, while serum levels were 1.4 and 1.5 times lower than adults. In all treatment and age groups, strontium was preferred to barium even though equal molar concentrations were dosed. This study displayed spatial co-localization of barium and strontium in bone for the first time. Barium and strontium can be used as surrogates for calcium to study the pathological changes in animal models of bone disease and to study the effects of pharmaceutical compounds on bone micro-architecture and bone remodeling in high spatial sensitivity and precision.

  2. Bioabsorbable bone fixation plates for X-ray imaging diagnosis by a radiopaque layer of barium sulfate and poly(lactic-co-glycolic acid).

    PubMed

    Choi, Sung Yoon; Hur, Woojune; Kim, Byeung Kyu; Shasteen, Catherine; Kim, Myung Hun; Choi, La Mee; Lee, Seung Ho; Park, Chun Gwon; Park, Min; Min, Hye Sook; Kim, Sukwha; Choi, Tae Hyun; Choy, Young Bin

    2015-04-01

    Bone fixation systems made of biodegradable polymers are radiolucent, making post-operative diagnosis with X-ray imaging a challenge. In this study, to allow X-ray visibility, we separately prepared a radiopaque layer and attached it to a bioabsorbable bone plate approved for clinical use (Inion, Finland). We employed barium sulfate as a radiopaque material due to the high X-ray attenuation coefficient of barium (2.196 cm(2) /g). The radiopaque layer was composed of a fine powder of barium sulfate bound to a biodegradable material, poly(lactic-co-glycolic acid) (PLGA), to allow layer degradation similar to the original Inion bone plate. In this study, we varied the mass ratio of barium sulfate and PLGA in the layer between 3:1 w/w and 10:1 w/w to modulate the degree and longevity of X-ray visibility. All radiopaque plates herein were visible via X-ray, both in vitro and in vivo, for up to 40 days. For all layer types, the radio-opacity decreased with time due to the swelling and degradation of PLGA, and the change in the layer shape was more apparent for layers with a higher PLGA content. The radiopaque plates released, at most, 0.5 mg of barium sulfate every 2 days in a simulated in vitro environment, which did not appear to affect the cytotoxicity. The radiopaque plates also exhibited good biocompatibility, similar to that of the Inion plate. Therefore, we concluded that the barium sulfate-based, biodegradable plate prepared in this work has the potential to be used as a fixation device with both X-ray visibility and biocompatibility. © 2014 Wiley Periodicals, Inc.

  3. Magnetic field directed assembly of superstructures of ferrite-ferroelectric core-shell nanoparticles and studies on magneto-electric interactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Srinivasan, G., E-mail: srinivas@oakland.edu; Sreenivasulu, G.; Benoit, Crystal

    2015-05-07

    Composites of ferromagnetic and ferroelectric are of interest for studies on mechanical strain mediated magneto-electric (ME) interactions and for useful technologies. Here, we report on magnetic-field-assisted-assembly of barium titanate (BTO)-nickel ferrite (NFO) core-shell particles into linear chains and 2D/3D arrays and measurements of ME effects in such assemblies. First, we synthesized the core-shell nano-particles with 50–600 nm BTO and 10–200 nm NFO by chemical self-assembly by coating the ferroic particles with complementary coupling groups and allowing them to self-assemble in the presence of a catalyst via the “click” reaction. The core-shell structure was confirmed with electron microscopy and scanning probe microscopy. Wemore » obtained superstructure of the core-shell particles by subjecting them to a magnetic field gradient that exerts an attractive force on the particles and align them toward the regions of high field strengths. At low particle concentration, linear chains were formed and they evolved into 2D and 3D arrays at high particle concentrations. Magnetoelectric characterization on unassembled films and assembled arrays has been performed through measurements of low-frequency ME voltage coefficient (MEVC) by subjecting the sample to a bias magnetic field and an ac magnetic field. The MEVC is higher for field-assembled samples than for unassembled films and is found to be sensitive to field orientation with a higher MEVC for magnetic fields parallel to the array direction than for magnetic fields perpendicular to the array. A maximum MEVC of 20 mV/cm Oe, one of the highest reported for any bulk nanocomposite, is measured across the array thickness. A model is provided for ME coupling in the superstructures of BTO-NFO particulate composites. First, we estimated the MEVC for a free-standing BTO-NFO core-shell particle and then extended the model to include an array of linear chains of the particles. The theoretical estimates are in qualitative agreement with the data.« less

  4. Magnetic field directed assembly of superstructures of ferrite-ferroelectric core-shell nanoparticles and studies on magneto-electric interactions

    NASA Astrophysics Data System (ADS)

    Srinivasan, G.; Sreenivasulu, G.; Benoit, Crystal; Petrov, V. M.; Chavez, F.

    2015-05-01

    Composites of ferromagnetic and ferroelectric are of interest for studies on mechanical strain mediated magneto-electric (ME) interactions and for useful technologies. Here, we report on magnetic-field-assisted-assembly of barium titanate (BTO)-nickel ferrite (NFO) core-shell particles into linear chains and 2D/3D arrays and measurements of ME effects in such assemblies. First, we synthesized the core-shell nano-particles with 50-600 nm BTO and 10-200 nm NFO by chemical self-assembly by coating the ferroic particles with complementary coupling groups and allowing them to self-assemble in the presence of a catalyst via the "click" reaction. The core-shell structure was confirmed with electron microscopy and scanning probe microscopy. We obtained superstructure of the core-shell particles by subjecting them to a magnetic field gradient that exerts an attractive force on the particles and align them toward the regions of high field strengths. At low particle concentration, linear chains were formed and they evolved into 2D and 3D arrays at high particle concentrations. Magnetoelectric characterization on unassembled films and assembled arrays has been performed through measurements of low-frequency ME voltage coefficient (MEVC) by subjecting the sample to a bias magnetic field and an ac magnetic field. The MEVC is higher for field-assembled samples than for unassembled films and is found to be sensitive to field orientation with a higher MEVC for magnetic fields parallel to the array direction than for magnetic fields perpendicular to the array. A maximum MEVC of 20 mV/cm Oe, one of the highest reported for any bulk nanocomposite, is measured across the array thickness. A model is provided for ME coupling in the superstructures of BTO-NFO particulate composites. First, we estimated the MEVC for a free-standing BTO-NFO core-shell particle and then extended the model to include an array of linear chains of the particles. The theoretical estimates are in qualitative agreement with the data.

  5. Health Effects Associated with Water Fluoridation.

    ERIC Educational Resources Information Center

    Richmond, Virginia L.

    1979-01-01

    Discussion is presented concerning fluoridation of water supplies. Correlation between fluoride in drinking water and improved dental health is reviewed. Relationship is expressed between fluoridation and reduced tooth decay. Use of fluoride in treating skeletal disorders is discussed. Author advocates fluoridating water supplies. (SA)

  6. Morphology control of anisotropic BaTiO 3 and BaTiOF 4 using organic-inorganic interaction

    NASA Astrophysics Data System (ADS)

    Masuda, Yoshitake; Tanaka, Yuki; Gao, Yanfeng; Koumoto, Kunihito

    2009-01-01

    We proposed a novel concept for morphology control of barium titanate precursor to fabricate platy particles. Organic molecules play an essential role in the crystallization of BaTiOF 4 to synthesize multi-needle particles, polyhedron particles or platy particles in an aqueous solution. Precursors were successfully transformed to barium titanate single phase by annealing. Platy barium titanate precursor particles are expected for future multilayer ceramic capacitors.

  7. A search for technetium (Tc II) in barium stars

    NASA Technical Reports Server (NTRS)

    Little-Marenin, Irene R.; Little, Stephen J.

    1987-01-01

    The authors searched without success for the lines of Tc II at 2647.02, 2610.00 and 2543.24 A in IUE spectra of the barium stars HR 5058, Omicron Vir, and Zeta Cap. The lack of Tc II implies that the observed s-process enhancements were produced more than half a million years ago and supports the suggestion that the spectral peculiarities of barium stars are probably related to the binary nature of the stars.

  8. Comparison of the reflectance characteristics of polytetrafluoroethylene and barium sulfate paints

    NASA Technical Reports Server (NTRS)

    Butner, C. L.; Schutt, J. B.; Shai, M. C.

    1984-01-01

    Preliminary results are presented of the directional reflectance measurements taken on two tetrafluorethylene (TFE) paints formulated with silicone binders. Both paints are found to be more Lambertian than barium sulfate paint and pressed powder, although the pigment to binder ratios for barium sulfate and TFE paints are about 133 and 3.3 to 1, respectively. The TFE paints exhibit total visible reflectances above 90 percent and offer surfaces that are not significantly affected by water.

  9. Effects of Different Fabrication Techniques on the Yttrium-Barium-Copper Oxide High Temperature Superconductor

    DTIC Science & Technology

    1988-12-01

    and barium peroxide. The eperimental design includes barium carbonate as a precursor since it is a comronly used starting material for the ccupound...Kerans, Materials Laboratory, for his assistance in designing this project. I would also like to thank Tim Peterson for his patient instructing. I...the design of the devices used for taking measurements was detailed. Chapter IV showed the results of each type of measurement on each individual

  10. Colonoscopy can miss diverticula of the left colon identified by barium enema

    PubMed Central

    Niikura, Ryota; Nagata, Naoyoshi; Shimbo, Takuro; Akiyama, Junichi; Uemura, Naomi

    2013-01-01

    AIM: To identify the diagnostic value of colonoscopy for diverticulosis as determined by barium enema. METHODS: A total of 65 patients with hematochezia who underwent colonoscopy and barium enema were analyzed, and the diagnostic value of colonoscopy for diverticula was assessed. The receiver operating characteristic area under the curve was compared in relation to age (< 70 or ≥ 70 years), sex, and colon location. The number of diverticula was counted, and the detection ratio was calculated. RESULTS: Colonic diverticula were observed in 46 patients with barium enema. Colonoscopy had a sensitivity of 91% and specificity of 90%. No significant differences were found in the receiver operating characteristic area under the curve (ROC-AUC) for age group or sex. The ROC-AUC of the left colon was significantly lower than that of the right colon (0.81 vs 0.96, P = 0.02). Colonoscopy identified 486 colonic diverticula, while barium enema identified 1186. The detection ratio for the entire colon was therefore 0.41 (486/1186). The detection ratio in the left colon (0.32, 189/588) was significantly lower than that of the right colon (0.50, 297/598) (P < 0.01). CONCLUSION: Compared with barium enema, only half the number of colonic diverticula can be detected by colonoscopy in the entire colon and even less in the left colon. PMID:23613630

  11. Strontium and barium isotopes in presolar silicon carbide grains measured with CHILI—two types of X grains

    DOE PAGES

    Stephan, Thomas; Trappitsch, Reto; Davis, Andrew M.; ...

    2017-05-10

    Here, we used CHILI, the Chicago Instrument for Laser Ionization, a new resonance ionization mass spectrometer developed for isotopic analysis of small samples, to analyze strontium, zirconium, and barium isotopes in 22 presolar silicon carbide grains. Twenty of the grains showed detectable strontium and barium, but none of the grains had enough zirconium to be detected with CHILI. Nine grains were excluded from further consideration since they showed very little signals (<1000 counts) for strontium as well as for barium. Among the 11 remaining grains, we found three X grains. The discovery of three supernova grains among only 22 grainsmore » was fortuitous, because only ~1% of presolar silicon carbide grains are type X, but was confirmed by silicon isotopic measurements of grain residues with NanoSIMS. And while one of the X grains showed strontium and barium isotope patterns expected for supernova grains, the two other supernova grains have 87Sr/86Sr < 0.5, values never observed in any natural sample before. From their silicon isotope ratios, the latter two grains can be classified as X2 grains, while the former grain belongs to the more common X1 group. The differences of these grains in strontium and barium isotopic composition constrain their individual formation conditions in Type II supernovae.« less

  12. Strontium and barium isotopes in presolar silicon carbide grains measured with CHILI—two types of X grains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stephan, Thomas; Trappitsch, Reto; Davis, Andrew M.

    Here, we used CHILI, the Chicago Instrument for Laser Ionization, a new resonance ionization mass spectrometer developed for isotopic analysis of small samples, to analyze strontium, zirconium, and barium isotopes in 22 presolar silicon carbide grains. Twenty of the grains showed detectable strontium and barium, but none of the grains had enough zirconium to be detected with CHILI. Nine grains were excluded from further consideration since they showed very little signals (<1000 counts) for strontium as well as for barium. Among the 11 remaining grains, we found three X grains. The discovery of three supernova grains among only 22 grainsmore » was fortuitous, because only ~1% of presolar silicon carbide grains are type X, but was confirmed by silicon isotopic measurements of grain residues with NanoSIMS. And while one of the X grains showed strontium and barium isotope patterns expected for supernova grains, the two other supernova grains have 87Sr/86Sr < 0.5, values never observed in any natural sample before. From their silicon isotope ratios, the latter two grains can be classified as X2 grains, while the former grain belongs to the more common X1 group. The differences of these grains in strontium and barium isotopic composition constrain their individual formation conditions in Type II supernovae.« less

  13. Effect of barium sulfate contrast medium on rheology and sensory texture attributes in a model food.

    PubMed

    Ekberg, O; Bulow, M; Ekman, S; Hall, G; Stading, M; Wendin, K

    2009-03-01

    The swallowing process can be visualized using videoradiography, by mixing food with contrast medium, e.g., barium sulfate (BaSO(4)), making it radiopaque. The sensory properties of foods may be affected by adding this medium. To evaluate if and to what extent sensory and rheological characteristics of mango purée were altered by adding barium sulfate to the food. This study evaluated four food samples based on mango purée, with no or added barium sulfate contrast medium (0%, 12.5%, 25.0%, and 37.5%), by a radiographic method, and measured sensory texture properties and rheological characteristics. The sensory evaluation was performed by an external trained panel using quantitative descriptive analysis. The ease of swallowing the foods was also evaluated. The sensory texture properties of mango purée were significantly affected by the added barium in all evaluated attributes, as was the perception of particles. Moreover, ease of swallowing was significantly higher in the sample without added contrast medium. All samples decreased in extensional viscosity with increasing extension rate, i.e., all samples were tension thinning. Shear viscosity was not as dependent on the concentration of BaSO(4) as extensional viscosity. Addition of barium sulfate to a model food of mango purée has a major impact on perceived sensory texture attributes as well as on rheological parameters.

  14. Acoustically based fetal heart rate monitor

    NASA Technical Reports Server (NTRS)

    Baker, Donald A.; Zuckerwar, Allan J.

    1991-01-01

    The acoustically based fetal heart rate monitor permits an expectant mother to perform the fetal Non-Stress Test in her home. The potential market would include the one million U.S. pregnancies per year requiring this type of prenatal surveillance. The monitor uses polyvinylidene fluoride (PVF2) piezoelectric polymer film for the acoustic sensors, which are mounted in a seven-element array on a cummerbund. Evaluation of the sensor ouput signals utilizes a digital signal processor, which performs a linear prediction routine in real time. Clinical tests reveal that the acoustically based monitor provides Non-Stress Test records which are comparable to those obtained with a commercial ultrasonic transducer.

  15. Barium-cross-linked alginate-gelatine microcapsule as a potential platform for stem cell production and modular tissue formation.

    PubMed

    Alizadeh Sardroud, Hamed; Nemati, Sorour; Baradar Khoshfetrat, Ali; Nabavinia, Mahbobeh; Beygi Khosrowshahi, Younes

    2017-08-01

    Influence of gelatine concentration and cross-linker ions of Ca 2+ and Ba 2+ was evaluated on characteristics of alginate hydrogels and proliferation behaviours of model adherent and suspendable stem cells of fibroblast and U937 embedded in alginate microcapsules. Increasing gelatine concentration to 2.5% increased extent of swelling to 15% and 25% for barium- and calcium-cross-linked hydrogels, respectively. Mechanical properties also decreased with increasing swelling of hydrogels. Both by increasing gelatine concentration and using barium ions increased considerably the proliferation of encapsulated model stem cells. Barium-cross-linked alginate-gelatine microcapsule tested for bone building block showed a 13.5 ± 1.5-fold expansion for osteoblast cells after 21 days with deposition of bone matrix. The haematopoietic stem cells cultured in the microcapsule after 7 days also showed up to 2-fold increase without adding any growth factor. The study demonstrates that barium-cross-linked alginate-gelatine microcapsule has potential for use as a simple and efficient 3D platform for stem cell production and modular tissue formation.

  16. Demonstrating the potential of yttrium-doped barium zirconate electrolyte for high-performance fuel cells.

    PubMed

    Bae, Kiho; Jang, Dong Young; Choi, Hyung Jong; Kim, Donghwan; Hong, Jongsup; Kim, Byung-Kook; Lee, Jong-Ho; Son, Ji-Won; Shim, Joon Hyung

    2017-02-23

    In reducing the high operating temperatures (≥800 °C) of solid-oxide fuel cells, use of protonic ceramics as an alternative electrolyte material is attractive due to their high conductivity and low activation energy in a low-temperature regime (≤600 °C). Among many protonic ceramics, yttrium-doped barium zirconate has attracted attention due to its excellent chemical stability, which is the main issue in protonic-ceramic fuel cells. However, poor sinterability of yttrium-doped barium zirconate discourages its fabrication as a thin-film electrolyte and integration on porous anode supports, both of which are essential to achieve high performance. Here we fabricate a protonic-ceramic fuel cell using a thin-film-deposited yttrium-doped barium zirconate electrolyte with no impeding grain boundaries owing to the columnar structure tightly integrated with nanogranular cathode and nanoporous anode supports, which to the best of our knowledge exhibits a record high-power output of up to an order of magnitude higher than those of other reported barium zirconate-based fuel cells.

  17. Growth and optical property characterization of textured barium titanate thin films for photonic applications

    NASA Astrophysics Data System (ADS)

    Dicken, Matthew J.; Diest, Kenneth; Park, Young-Bae; Atwater, Harry A.

    2007-03-01

    We have investigated the growth of barium titanate thin films on bulk crystalline and amorphous substrates utilizing biaxially oriented template layers. Ion beam-assisted deposition was used to grow thin, biaxially textured, magnesium oxide template layers on amorphous and silicon substrates. Growth of highly oriented barium titanate films on these template layers was achieved by molecular beam epitaxy using a layer-by-layer growth process. Barium titanate thin films were grown in molecular oxygen and in the presence of oxygen radicals produced by a 300 W radio frequency plasma. We used X-ray and in situ reflection high-energy electron diffraction (RHEED) to analyze the structural properties and show the predominantly c-oriented grains in the films. Variable angle spectroscopic ellipsometry was used to analyze and compare the optical properties of the thin films grown with and without oxygen plasma. We have shown that optical quality barium titanate thin films, which show bulk crystal-like properties, can be grown on any substrate through the use of biaxially oriented magnesium oxide template layers.

  18. Absorption, distribution and excretion of inhaled hydrogen fluoride in the rat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, J.B.

    1979-01-01

    Rats were subjected to whole body HF exposure for 6 hrs or to nose-only HF exposure for 1 hr. Total and/or ionic fluoride concentrations in selected tissues were determined at various times following exposure. In rats sacrificed 6 hrs after whole body exposure, dose-dependent increases in lung, plasma, and kidney total and ionic fluoride concentration occurred. Rats excreted more fluoride in the urine after whole body exposure than could be explained by the amount of HF inhaled. Considerable evidence suggests that airborne HF deposits on fur and is then ingested due to preening activity. Urinary fluoride excretion was increased bymore » nose-only exposure. The urinary fluoride excretion accounted for approximately twice the fluoride estimated to be inhaled during exposure. Tissue fluoride concentrations were elevated immediately after nose-only exposure. Fluoride concentrations in lung and kidney returned to control levels within 12 hrs. Plasma fluoride concentration was slightly elevated 24 hrs after the start of the 1 hr exposure but was at control levels at 96 hrs. Immediately following nose-only exposure, lung ionic fluoride concentrations were less than plasma ionic fluoride concentrations suggesting that the fluoride in the lung had reached that site via plasma transport rather than by inhalation. A dose-dependent increase in plasma ionic fluoride concentration occurred after upper respiratory tract HF exposure providing strong evidence that fluoride is absorbed systemically from that site. The plasma ionic fluoride concentration after upper respiratory tract exposure was of sufficient magnitude to account for the plasma fluoride concentrations observed in intact nose-only exposed rats. (ERB)« less

  19. Exposure to water fluoridation and caries increment.

    PubMed

    Spencer, A J; Armfield, J M; Slade, G D

    2008-03-01

    The objective of this cohort study was to examine the association between exposure to water fluoridation and the increment of dental caries in two Australian states: Queensland (Qld)--5 per cent fluoridation coverage; and South Australia (SA)--70 per cent fluoridation coverage. Stratified random samples were drawn from fluoridated Adelaide and the largely non-fluoridated rest-of-state in SA, and fluoridated Townsville and non-fluoridated Brisbane in Qld. Children were enrolled between 1991 and 1992 (SA: 5-15 yrs old, n = 9,980; Qld: 5-12 yrs old, n = 10,695). Follow-up caries status data for 3 years (+/- 1/2 year) were available on 8,183 children in SA and 6,711 children in Qld. Baseline data on lifetime exposure to fluoridated water, use of other fluorides and socio-economic status (SES) were collected by questionnaire, and tooth surface caries status by dental examinations in school dental service clinics. Higher per cent lifetime exposure to fluoridated water (6 categories: 0;1-24; 25-49; 50-74; 75-99; 100 per cent) was a significant predictor (ANOVA, p < 0.01) of lower annualised Net Caries Increment (NCI) for the deciduous dentition in SA and Qld, but only for Qld in the permanent dentition. These associations persisted in multiple linear regression analyses controlling for age, gender, exposure to other fluorides and SES (p < 0.05). Water fluoridation was effective in reducing caries increment, even in the presence of a dilution effect from other fluorides. The effect of fluoridated water consumption was strongest in the deciduous dentition and where diffusion of food and beverages from fluoridated to non-fluoridated areas was less likely.

  20. Observation and theory of the barium releases from the CRRES satellite

    NASA Technical Reports Server (NTRS)

    Bernhardt, P. A.; Huba, J. D.; Scales, W. A.; Wescott, E. M.; Stenbaek-Nielsen, H. C.

    1992-01-01

    The relationship between releases of barium from the NASA Combined Release and Radiation Effects Satellite (CRRES) and enhanced auroral activity is discussed with reference to observational data. Barium releases were conducted at a variety of altitudes and injection velocities, and plasma irregularities are reported as a result of the interactions. Auroral activity increased within 5 min of each release, and references are made to the effects on diamagnetic cavities, bulk ion motion, and stimulated electron and ion precipitation. Artificially created structured diamagnetic cavities are noted for each release, plasma waves are generated by the high-speed ion clouds, and enhanced ionization is found in the critical ionization-velocity process. Barium releases are effective in stimulating electron precipitation, and the observed irregularities are related to cycloid bunching of the initial ion distributions.

  1. The review of various synthesis methods of barium titanate with the enhanced dielectric properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    More, S. P., E-mail: smitalomte@gmail.com; Topare, R. J., E-mail: r-topare@yahoo.com

    2016-05-06

    The Barium Titanate is a very well known dielectric ceramic belongs to perovskite structure. It has very wide applications in the field of electronic, electro ceramic, electromechanical and electro-optical applications. Barium Titanate has very high dielectric constant as well as low dielectric loss. Substituted dielectrics are one of the most important technological compounds in modern electro ceramics. Its electrical properties can be tuned flexibly by a simple substitution technique. This has encouraged researchers to select a typical cation to be substituted at cationic sites. In the present paper, the review of various synthesis methods of Barium Titanate compound with themore » effect of different dopants, the grain size on the dielectric properties at various temperatures is discussed.« less

  2. Rare earth-doped barium gallo-germanate glasses and their near-infrared luminescence properties.

    PubMed

    Pisarska, Joanna; Sołtys, Marta; Górny, Agata; Kochanowicz, Marcin; Zmojda, Jacek; Dorosz, Jan; Dorosz, Dominik; Sitarz, Maciej; Pisarski, Wojciech A

    2018-08-05

    Near-infrared luminescence properties of Nd 3+ and Ho 3+ ions in barium gallo-germanate glasses have been reported. Several spectroscopic parameters for Nd 3+ and Ho 3+ ions have been determined from the Judd-Ofelt analysis and absorption/luminescence measurements. Quite large luminescence lifetime, quantum efficiency and stimulated emission cross-section have been obtained for the main 4 F 3/2  →  4 I 11/2 (Nd 3+ ) and 5 I 7  →  5 I 8 (Ho 3+ ) laser transitions of rare earths in barium gallo-germanate glasses. It suggests that barium gallo-germanate glass is promising for near-infrared laser application at emission wavelengths 1064 nm (Nd 3+ ) and 2020 nm (Ho 3+ ). Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Physiologic Conditions Affect Toxicity of Ingested Industrial Fluoride

    PubMed Central

    Sauerheber, Richard

    2013-01-01

    The effects of calcium ion and broad pH ranges on free fluoride ion aqueous concentrations were measured directly and computed theoretically. Solubility calculations indicate that blood fluoride concentrations that occur in lethal poisonings would decrease calcium below prevailing levels. Acute lethal poisoning and also many of the chronic effects of fluoride involve alterations in the chemical activity of calcium by the fluoride ion. Natural calcium fluoride with low solubility and toxicity from ingestion is distinct from fully soluble toxic industrial fluorides. The toxicity of fluoride is determined by environmental conditions and the positive cations present. At a pH typical of gastric juice, fluoride is largely protonated as hydrofluoric acid HF. Industrial fluoride ingested from treated water enters saliva at levels too low to affect dental caries. Blood levels during lifelong consumption can harm heart, bone, brain, and even developing teeth enamel. The widespread policy known as water fluoridation is discussed in light of these findings. PMID:23840230

  4. Physiologic conditions affect toxicity of ingested industrial fluoride.

    PubMed

    Sauerheber, Richard

    2013-01-01

    The effects of calcium ion and broad pH ranges on free fluoride ion aqueous concentrations were measured directly and computed theoretically. Solubility calculations indicate that blood fluoride concentrations that occur in lethal poisonings would decrease calcium below prevailing levels. Acute lethal poisoning and also many of the chronic effects of fluoride involve alterations in the chemical activity of calcium by the fluoride ion. Natural calcium fluoride with low solubility and toxicity from ingestion is distinct from fully soluble toxic industrial fluorides. The toxicity of fluoride is determined by environmental conditions and the positive cations present. At a pH typical of gastric juice, fluoride is largely protonated as hydrofluoric acid HF. Industrial fluoride ingested from treated water enters saliva at levels too low to affect dental caries. Blood levels during lifelong consumption can harm heart, bone, brain, and even developing teeth enamel. The widespread policy known as water fluoridation is discussed in light of these findings.

  5. 21 CFR 177.2510 - Polyvinylidene fluoride resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Polyvinylidene fluoride resins. 177.2510 Section... Repeated Use § 177.2510 Polyvinylidene fluoride resins. Polyvinylidene fluoride resins may be safely used... fluoride resins consist of basic resins produced by the polymerization of vinylidene fluoride. (b) The...

  6. Laboratory Testing and Performance Verification of the CHARIS Integral Field Spectrograph

    NASA Technical Reports Server (NTRS)

    Groff, Tyler D.; Chilcote, Jeffrey; Kasdin, N. Jeremy; Galvin, Michael; Loomis, Craig; Carr, Michael A.; Brandt, Timothy; Knapp, Gillian; Limbach, Mary Anne; Guyon, Olivier; hide

    2016-01-01

    The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) that has been built for the Subaru telescope. CHARIS has two imaging modes; the high-resolution mode is R82, R69, and R82 in J, H, and K bands respectively while the low-resolution discovery mode uses a second low-resolution prism with R19 spanning 1.15-2.37 microns (J+H+K bands). The discovery mode is meant to augment the low inner working angle of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) adaptive optics system, which feeds CHARIS a coronagraphic image. The goal is to detect and characterize brown dwarfs and hot Jovian planets down to contrasts five orders of magnitude dimmer than their parent star at an inner working angle as low as 80 milliarcseconds. CHARIS constrains spectral crosstalk through several key aspects of the optical design. Additionally, the repeatability of alignment of certain optical components is critical to the calibrations required for the data pipeline. Specifically the relative alignment of the lens let array, prism, and detector must be highly stable and repeatable between imaging modes. We report on the measured repeatability and stability of these mechanisms, measurements of spectral crosstalk in the instrument, and the propagation of these errors through the data pipeline. Another key design feature of CHARIS is the prism, which pairs Barium Fluoride with Ohara L-BBH2 high index glass. The dispersion of the prism is significantly more uniform than other glass choices, and the CHARIS prisms represent the first NIR astronomical instrument that uses L-BBH2as the high index material. This material choice was key to the utility of the discovery mode, so significant efforts were put into cryogenic characterization of the material. The final performance of the prism assemblies in their operating environment is described in detail. The spectrograph is going through final alignment, cryogenic cycling, and is being delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.

  7. Comparison of in vitro fluoride uptake from whitening toothpastes and a conventional toothpaste in demineralised enamel.

    PubMed

    Altenburger, Markus J; Bernhart, Jasmin; Schicha, Thurid D; Wrbas, Karl-Thomas; Hellwig, Elmar

    2010-01-01

    Studies on the compatibility of abrasives and fluoride compounds deal exclusively with fluoride uptake and remineralization after storing the enamel specimens in a toothpaste-saliva mixture. The influence of brushing on the fluoride uptake when highly abrasive toothpastes are used has hardly been investigated so far. The aim of the present study was to investigate fluoride uptake in initially demineralised dental enamel after storage in, or brushing with, whitening toothpaste slurries, compared to a conventional toothpaste. For this purpose two widely available whitening toothpastes with ionically bound fluoride (sodium fluoride NaF), two with covalently-bound fluoride toothpastes (sodium monofluorophosphate, NaMFP) and a conventional amine fluoride toothpaste (AmF) were compared. The fluoride uptake after use of the AmF toothpaste was shown to be statistically significantly higher than that after application of the NaF toothpastes, which in turn was statistically significantly higher than the uptake resulting from NaMFP application. The fluoride uptake was slightly higher when the enamel samples were brushed with NaF toothpaste, rather than just stored in the respective toothpaste slurry. Brushing with highly abrasive toothpastes did not negatively influence fluoride uptake in demineralised dental enamel. The ionic form of the fluoride in toothpastes appears to be critical for increased fluoride uptake. The acidic components of the AmF toothpaste improved fluoride uptake compared to alkaline NaF toothpastes.

  8. The effective use of fluorides in public health.

    PubMed Central

    Jones, Sheila; Burt, Brian A.; Petersen, Poul Erik; Lennon, Michael A.

    2005-01-01

    Dental caries remain a public health problem for many developing countries and for underprivileged populations in developed countries. This paper outlines the historical development of public health approaches to the use of fluoride and comments on their effectiveness. Early research and development was concerned with waterborne fluorides, both naturally occurring and added, and their effects on the prevalence and incidence of dental caries and dental fluorosis. In the latter half of the 20th century, the focus of research was on fluoride toothpastes and mouth rinses. More recently, systematic reviews summarizing these extensive databases have indicated that water fluoridation and fluoride toothpastes both substantially reduce the prevalence and incidence of dental caries. We present four case studies that illustrate the use of fluoride in modern public health practice, focusing on: recent water fluoridation schemes in California, USA; salt fluoridation in Jamaica; milk fluoridation in Chile; and the development of "affordable" fluoride toothpastes in Indonesia. Common themes are the concern to reduce demands for compliance with fluoride regimes that rely upon action by individuals and their families, and the issue of cost. We recommend that a community should use no more than one systemic fluoride (i.e. water or salt or milk fluoridation) combined with the use of fluoride toothpastes, and that the prevalence of dental fluorosis should be monitored in order to detect increases in or higher-than-acceptable levels. PMID:16211158

  9. Solid state electrochemical current source

    DOEpatents

    Potanin, Alexander Arkadyevich; Vedeneev, Nikolai Ivanovich

    2002-04-30

    A cathode and a solid state electrochemical cell comprising said cathode, a solid anode and solid fluoride ion conducting electrolyte. The cathode comprises a metal oxide and a compound fluoride containing at least two metals with different valences. Representative compound fluorides include solid solutions of bismuth fluoride and potassium fluoride; and lead fluoride and potassium fluoride. Representative metal oxides include copper oxide, lead oxide, manganese oxide, vanadium oxide and silver oxide.

  10. 76 FR 37129 - Determination That SODIUM FLUORIDE F 18 (Sodium Fluoride F-18) Injection, 10 to 200 Millicuries...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ...] Determination That SODIUM FLUORIDE F 18 (Sodium Fluoride F-18) Injection, 10 to 200 Millicuries per Milliliter... FLUORIDE F 18 (sodium fluoride F-18) injection, 10 to 200 millicuries per milliliter (mCi/mL), was not... abbreviated new drug applications (ANDAs) for SODIUM FLUORIDE F 18 injection, 10 to 200 mCi/mL, if all other...

  11. Process for converting magnesium fluoride to calcium fluoride

    DOEpatents

    Kreuzmann, A.B.; Palmer, D.A.

    1984-12-21

    This invention is a process for the conversion of magnesium fluoride to calcium fluoride whereby magnesium fluoride is decomposed by heating in the presence of calcium carbonate, calcium oxide or calcium hydroxide. Magnesium fluoride is a by-product of the reduction of uranium tetrafluoride to form uranium metal and has no known commercial use, thus its production creates a significant storage problem. The advantage of this invention is that the quality of calcium fluoride produced is sufficient to be used in the industrial manufacture of anhydrous hydrogen fluoride, steel mill flux or ceramic applications.

  12. Health effects of groundwater fluoride contamination.

    PubMed

    Nayak, Bishwajit; Roy, Madan Mohan; Das, Bhaskar; Pal, Arup; Sengupta, Mrinal Kumar; De, Shankar Prasad; Chakraborti, Dipankar

    2009-04-01

    The people in Berhait block, Sahibganj district, Jharkhand state, India, have been exposed chronically to fluoridecontaminated groundwater. Hereby, we report the clinical effects of chronic exposure to fluoride. The study population was a convenience sample of 342 adults and 258 children living in the affected area. All volunteers filled out questionnaires and were examined. Well water from the six affected villages and urine samples were analyzed for fluoride using an ion-sensitive electrode. Twenty nine percent of 89 well water samples had fluoride concentrations above the Indian permissible limit of fluoride in drinking water. Eighty-five children and 72 adults had clinical fluorosis. Urine fluoride concentrations in children were 0.758-2.88 mg/L whereas in adults they were 0.331-10.36 mg/L. Clinical effects of fluoride included abnormal tooth enamel in children; adults had joint pain and deformity of the limbs and spine, along with ligamentous calcifications and exostosis formations in seven patients. Elevated urine fluoride concentrations supported the clinical diagnosis of fluorosis. Owing to insufficient fluoride-safe wells and lack of awareness of the danger of fluoride toxicity, villagers often drink fluoride-contaminated water. Villagers of Berhait block, including children, are at risk from chronic fluoride toxicity. To combat the situation, villagers need fluoride-safe water, education, and awareness of the danger about fluoride toxicity.

  13. RADIATION SOURCES

    DOEpatents

    Brucer, M.H.

    1958-04-15

    A novel long-lived source of gamma radiation especially suitable for calibration purposes is described. The source of gamma radiation is denoted mock iodine131, which comprises a naixture of barium-133 and cesium-137. The barium and cesium are present in a barium-cesium ratio of approximately 5.7/1 to 14/1, uniformly dispersed in an ion exchange resin and a filter surrounding the resin comprised of a material of atomic number below approximately 51, and substantially 0.7 to 0.9 millimeter thick.

  14. Barium isotopes in Allende meteorite - Evidence against an extinct superheavy element

    NASA Technical Reports Server (NTRS)

    Lewis, R. S.; Anders, E.; Shimamura, T.; Lugmair, G. W.

    1983-01-01

    Carbon and chromite fractions from the Allende meteorite that contain isotopically anomalous xenon-131 to xenon-136 (carbonaceous chondrite fission or CCF xenon) at up to 5 x 10 to the 11th atoms per gram show no detectable isotopic anomalies in barium-130 to barium-138. This rules out the possibility that the CCF xenon was formed by in situ fission of an extinct superheavy element. Apparently the CCF xenon and its carbonaceous carrier are relics from stellar nucleosynthesis.

  15. Consensus Statement of Society of Abdominal Radiology Disease-Focused Panel on Barium Esophagography in Gastroesophageal Reflux Disease.

    PubMed

    Levine, Marc S; Carucci, Laura R; DiSantis, David J; Einstein, David M; Hawn, Mary T; Martin-Harris, Bonnie; Katzka, David A; Morgan, Desiree E; Rubesin, Stephen E; Scholz, Francis J; Turner, Mary Ann; Wolf, Ellen L; Canon, Cheri L

    2016-11-01

    The Society of Abdominal Radiology established a panel to prepare a consensus statement on the role of barium esophagography in gastroesophageal reflux disease (GERD), as well as recommended techniques for performing the fluoroscopic examination and the gamut of findings associated with this condition. Because it is an inexpensive, noninvasive, and widely available study that requires no sedation, barium esophagography may be performed as the initial test for GERD or in conjunction with other tests such as endoscopy.

  16. Intensity-Dependence Absorption and Photorefractive Effects in Barium Titanate

    DTIC Science & Technology

    1988-09-01

    S) barium titanate (U) George A. Brost , Ra and A. Motes, James R. Rotge’ 13& TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT (Yr.. Mo.. Day) 15...the copyright owner. Inthnsity-dependent absorption and photorefractive effects in barium titanate0 ELECTE 0 G. A. Brost , R. A. Motes, and 1. R. Rotge...Opt. Soc. Am. B/Vol. 5, No. 9/September 1988 Brost et al. CONDUCTION BAND the relative contributions of photoconductivities and dark conductivities

  17. Appropriate uses of fluorides for children: guidelines from the Canadian Workshop on the Evaluation of Current Recommendations Concerning Fluorides.

    PubMed Central

    Clark, D C

    1993-01-01

    OBJECTIVE: To prevent fluorosis caused by excessive fluoride ingestion by revising recommendations for fluoride intake by children. OPTIONS: Limiting fluoride ingestion from fluoridated water, fluoride supplements and fluoride dentifrices. OUTCOMES: Reduction in the prevalence of dental fluorosis and continued prevention of dental caries. EVIDENCE: Before the workshop, experts prepared comprehensive literature reviews of fluoride therapies, fluoride ingestion and the prevalence and causes of dental fluorosis. The papers, which were peer-reviewed, revised and circulated to the workshop participants, formed the basis of the workshop discussions. VALUES: Recommendations to limit fluoride intake were vigorously debated before being adopted as the consensus opinion of the workshop group. BENEFITS, HARMS AND COSTS: Decrease in the prevalence of dental fluorosis with continuing preventive effects of fluoride use. The only significant cost would be in preparing new, low-concentration fluoride products for distribution. RECOMMENDATIONS: Fluoride supplementation should be limited to children 3 years of age and older in areas where there is less than 0.3 ppm of fluoride in the water supply. Children in all areas should use only a "pea-sized" amount of fluoride dentifrice no more than twice daily under the supervision of an adult. VALIDATION: These recommendations are almost identical to changes to recommendations for the use of fluoride supplements recently proposed by a group of European countries. SPONSORS: The workshop was organized by Dr. D. Christopher Clark, of the University of British Columbia, and Drs. Hardy Limeback and Ralph C. Burgess, of the University of Toronto, and funded by Proctor and Gamble Inc., Toronto, the Medical Research Council of Canada and Health Canada (formerly the Department of National Health and Welfare). The recommendations were formally adopted by the Canadian Dental Association in April 1993. PMID:8261348

  18. Review on fluoride-releasing restorative materials--fluoride release and uptake characteristics, antibacterial activity and influence on caries formation.

    PubMed

    Wiegand, Annette; Buchalla, Wolfgang; Attin, Thomas

    2007-03-01

    The purpose of this article was to review the fluoride release and recharge capabilities, and antibacterial properties, of fluoride-releasing dental restoratives, and discuss the current status concerning the prevention or inhibition of caries development and progression. Information from original scientific full papers or reviews listed in PubMed (search term: fluoride release AND (restorative OR glass-ionomer OR compomer OR polyacid-modified composite resin OR composite OR amalgam)), published from 1980 to 2004, was included in the review. Papers dealing with endodontic or orthodontic topics were not taken into consideration. Clinical studies concerning secondary caries development were only included when performed in split-mouth design with an observation period of at least three years. Fluoride-containing dental materials show clear differences in the fluoride release and uptake characteristics. Short- and long-term fluoride releases from restoratives are related to their matrices, setting mechanisms and fluoride content and depend on several environmental conditions. Fluoride-releasing materials may act as a fluoride reservoir and may increase the fluoride level in saliva, plaque and dental hard tissues. However, clinical studies exhibited conflicting data as to whether or not these materials significantly prevent or inhibit secondary caries and affect the growth of caries-associated bacteria compared to non-fluoridated restoratives. Fluoride release and uptake characteristics depend on the matrices, fillers and fluoride content as well as on the setting mechanisms and environmental conditions of the restoratives. Fluoride-releasing materials, predominantly glass-ionomers and compomers, did show cariostatic properties and may affect bacterial metabolism under simulated cariogenic conditions in vitro. However, it is not proven by prospective clinical studies whether the incidence of secondary caries can be significantly reduced by the fluoride release of restorative materials.

  19. Streptozotocin Aggravated Osteopathology and Insulin Induced Osteogenesis Through Co-treatment with Fluoride.

    PubMed

    Yang, Chen; Zhang, Mengmeng; Li, Yagang; Wang, Yan; Mao, Weixian; Gao, Yuan; Xu, Hui

    2015-12-01

    The role of insulin in the mechanism underlying the excessive fluoride that causes skeletal lesion was studied. The in vitro bone marrow stem cells (BMSC) collected from Kunming mice were exposed to varying concentrations of fluoride with or without insulin. The cell viability and early differentiation of BMSC co-treated with fluoride and insulin were measured by using cell counting kit-8 and Gomori modified calcium-cobalt method, respectively. We further investigated the in vivo effects of varying dose of fluoride on rats co-treated with streptozotocin (STZ). Wistar rats were divided into six groups which included normal control, 10 mg fluoride/kg day group, 20 mg fluoride/kg day group, STZ control, STZ+10 mg fluoride/kg day group, and STZ+20 mg fluoride/kg day group. The rats were administered with sodium fluoride (NaF) by gavage with water at doses 10 and 20 mg fluoride/kg day for 2 months. In a period of one month, half of rats in every group were treated with streptozotocin (STZ) once through intraperitoneal injection at 52 mg/kg body weight. The serum glucose, HbA1c, and insulin were determined. Bone mineral content and insulin release were assessed. The results showed insulin combined with fluoride stimulated BMSC cell viability in vitro. The bone mineral content reduced in rats treated with higher dose of fluoride and decreased immensely in rat co-treated with fluoride and STZ. Similarly, a combination treatment of a high dose of fluoride and STZ decreased insulin sensitivity and activity. To sum up, these data indicated fluoride influenced insulin release, activity, and sensitivity. Furthermore, the insulin state in vivo interfered in the osteogenesis in turn and implied there was a close relation between insulin and bone pathogenesis in the mechanism of fluoride toxicity.

  20. FLUORIDE: A REVIEW OF USE AND EFFECTS ON HEALTH.

    PubMed

    Kanduti, Domen; Sterbenk, Petra; Artnik, Barbara

    2016-04-01

    Appropriate oral health care is fundamental for any individual's health. Dental caries is still one of the major public health problems. The most effective way of caries prevention is the use of fluoride. The aim of our research was to review the literature about fluoride toxicity and to inform physicians, dentists and public health specialists whether fluoride use is expedient and safe. Data we used in our review were systematically searched and collected from web pages and documents published from different international institutions. Fluoride occurs naturally in our environment but we consume it in small amounts. Exposure can occur through dietary intake, respiration and fluoride supplements. The most important factor for fluoride presence in alimentation is fluoridated water. Methods, which led to greater fluoride exposure and lowered caries prevalence, are considered to be one of the greatest accomplishments in the 20th century`s public dental health. During pregnancy, the placenta acts as a barrier. The fluoride, therefore, crosses the placenta in low concentrations. Fluoride can be transmitted through the plasma into the mother's milk; however, the concentration is low. The most important action of fluoride is topical, when it is present in the saliva in the appropriate concentration. The most important effect of fluoride on caries incidence is through its role in the process of remineralization and demineralization of tooth enamel. Acute toxicity can occur after ingesting one or more doses of fluoride over a short time period which then leads to poisoning. Today, poisoning is mainly due to unsupervised ingestion of products for dental and oral hygiene and over-fluoridated water. Even though fluoride can be toxic in extremely high concentrations, it`s topical use is safe. The European Academy of Paediatric Dentistry (EAPD) recommends a preventive topical use of fluoride supplements because of their cariostatic effect.

  1. FLUORIDE CONTENT OF COMMERCIALLY AVAILABLE BOTTLED DRINKING WATER IN BANGKOK, THAILAND.

    PubMed

    Rirattanapong, Praphasri; Rirattanapong, Opas

    2016-09-01

    The use of bottled drinking water may be a source of fluoride and could be a risk factor for fluorosis among infants and young children. The aim of this study was to evaluate the fluoride content of commercially available bottled drinking water in Bangkok, Thailand. Forty-five water samples (15 samples of plain water and 30 samples of mineral water) were purchased from several supermarkets in Bangkok, Thailand. Three bottles of each water sample were purchased, and the fluoride content of each sample was measured twice using a combination fluoride-ion selective electrode. The average reading for each sample was then calculated. Data were analyzed by descriptive statistics. Differences between mineral and plain water samples were determined by Student’s t-test. The mean (±SD) fluoride content for all the water samples was 0.17 (±0.17) mg F/l (range: 0.01-0.89 mg F/l). Six brands (13%) tested stated the fluoride content on the label. The actual fluoride content in each of their brands varied little from the label. Eight samples (18%) had a fluoride content >0.3 mg F/l and two samples (4%) had a fluoride content >0.6 mg F/l. The mean mineral water fluoride concentration was significantly higher than the mean fluoride concentration of plain water (p=0.001). We found commercially sold bottled drinking water in Bangkok, Thailand contained varying concentrations of fluoride; some with high concentrations of fluoride. Health professions need to be aware this varying fluoride content of bottled drinking water and educate the parents of infants and small children about this when prescribing fluoride supplements. Consideration should be made to have fluoride content put on the label of bottled water especially among brands with a content >0.3 mg F/l.

  2. Evaluation of the direct and diffusion methods for the determination of fluoride content in table salt

    PubMed Central

    Martínez-Mier, E. Angeles; Soto-Rojas, Armando E.; Buckley, Christine M.; Margineda, Jorge; Zero, Domenick T.

    2010-01-01

    Objective The aim of this study was to assess methods currently used for analyzing fluoridated salt in order to identify the most useful method for this type of analysis. Basic research design Seventy-five fluoridated salt samples were obtained. Samples were analyzed for fluoride content, with and without pretreatment, using direct and diffusion methods. Element analysis was also conducted in selected samples. Fluoride was added to ultra pure NaCl and non-fluoridated commercial salt samples and Ca and Mg were added to fluoride samples in order to assess fluoride recoveries using modifications to the methods. Results Larger amounts of fluoride were found and recovered using diffusion than direct methods (96%–100% for diffusion vs. 67%–90% for direct). Statistically significant differences were obtained between direct and diffusion methods using different ion strength adjusters. Pretreatment methods reduced the amount of recovered fluoride. Determination of fluoride content was influenced both by the presence of NaCl and other ions in the salt. Conclusion Direct and diffusion techniques for analysis of fluoridated salt are suitable methods for fluoride analysis. The choice of method should depend on the purpose of the analysis. PMID:20088217

  3. [Estimation of exposure to fluoride in "Los Altos de Jalisco", México].

    PubMed

    Hurtado-Jiménez, Roberto; Gardea-Torresdey, Jorge

    2005-01-01

    To estimate the level of fluoride exposure and human health risks in Los Altos de Jalisco (Jalisco State Heights) region. This study was conducted between May and July 2002. The fluoride concentrations of 105 water wells and six tap water samples were electrochemically measured. Exposure doses to fluoride and total intake of fluoride were estimated for babies (10 kg), children (20 kg), and adults (70 kg). The fluoride concentration of the water samples ranged from 0.1 to 17.7 mg/l. More than 45% of the water samples exceeded the national guideline value for fluoride of 1.5 mg/l. The estimated values of the exposure doses to fluoride and total intake of fluoride were in the range of 0.04-1.8 mg/kg/d and 0.5-18.4 mg/d, respectively. Dental fluorosis, skeletal fluorosis, and bone fractures are some of the potential health risks due to the intake of high doses of fluoride for the population of Los Altos de Jalisco. In order to reduce health risks, fluoridated salt,fluoridated toothpastes, and drinking water containing more than 0.7 mg/l of fluoride should be avoided.

  4. Fluoride in the environment and its metabolism in humans.

    PubMed

    Jha, Sunil Kumar; Mishra, Vinay Kumar; Sharma, Dinesh Kumar; Damodaran, Thukkaram

    2011-01-01

    The presence of environmental fluoride and its impact on human health is well documented. When consumed in adequate quantity, fluoride prevents dental caries, assists in the formation of dental enamels, and prevents deficiencies in bone mineralization. At excessive exposure levels, ingestion of fluoride causes dental fluorosis skeletal fluorosis, and manifestations such as gastrointestinal, neurological, and urinary problems. The distribution of fluoride in the environment is uneven and largely is believed to derive from geogenic causes. The natural sources of fluoride are fluorite, fluorapatite, and cryolite, whereas anthropogenic sources include coal burning, oil refining, steel production, brick-making industries, and phosphatic fertilizer plants, among others. Among the various sources of fluoride in the environment, those of anthropogenic origin have occasionally been considered to be major ones. The gourndwater is more susceptible to fluoride accumulation and contamination than are other environmental media, primarily because of its contact with geological substrates underneath. The high fluoride concentration in water usually reflects the solubility of fluoride (CaF₂). High concentrations are also often associated with soft, alkaline, and calcium-deficient waters. The fluoride compounds that occur naturally in drinking water are almost totally bioavailable (90%) and are completely absorbed from the gastrointestinal tract. As a result, drinking water is considered to be the potential source of fluoride that causes fluorosis. Because the bioavailability of fluoride is generally reduced in humans when consumed with milk or a calcium-rich diet, it is highly recommended that the inhabitants of fluoride-contaminated areas should incorporate calcium-rich foods in their routine diet. Guidelines for limiting the fluoride intake from drinking water have been postulated by various authorities. Such limits are designed to protect public health and should reflect all fluoride intake sources, including dietary fluoride. The toxicological risks posed by fluoride could be better understood if epidemiological surveillance for dental and skeletal fluorosis would be systematically conducted in fluoride-affected areas. Such input would greatly improve understanding of the human dose-response relationship. Such surveillance of potentially high fluoride areas is also important because it would help to delineate, much earlier, the remedial measures that are appropriate for those areas.

  5. Potential fluoride toxicity from oral medicaments: A review.

    PubMed

    Ullah, Rizwan; Zafar, Muhammad Sohail; Shahani, Nazish

    2017-08-01

    The beneficial effects of fluoride on human oral health are well studied. There are numerous studies demonstrating that a small amount of fluoride delivered to the oral cavity decreases the prevalence of dental decay and results in stronger teeth and bones. However, ingestion of fluoride more than the recommended limit leads to toxicity and adverse effects. In order to update our understanding of fluoride and its potential toxicity, we have described the mechanisms of fluoride metabolism, toxic effects, and management of fluoride toxicity. The main aim of this review is to highlight the potential adverse effects of fluoride overdose and poorly understood toxicity. In addition, the related clinical significance of fluoride overdose and toxicity has been discussed.

  6. [Determination of barium in natural curative waters by ICP-OES technique. Part I. Waters taken on the area of health resorts in Poland].

    PubMed

    Garboś, Sławomir; Swiecicka, Dorota

    2011-01-01

    Maximum admissible concentration level (MACL) of barium in natural mineral waters, natural spring waters and potable waters was set at the level of 1 mg/l, while MACL of this element in natural curative waters intended for drinking therapies and inhalations were set at the levels of 1.0 mg/l and 10.0 mg/l, respectively. Those requirements were related to therapies which are applied longer than one month. Above mentioned maximum admissible concentration levels of barium in consumed waters were established after taking into account actual criteria of World Health Organization which determined the guidelines value for this element in water intended for human consumption at the level of 0.7 mg/l. In this work developed and validated method of determination of barium by inductively coupled plasma emission spectrometry technique was applied for determination of this element in 45 natural curative waters sampled from 24 spa districts situated on the area of Poland. Concentrations of barium determined were in the range from 0.0036 mg/l to 24.0 mg/l. Natural curative waters characterized by concentrations of barium in the ranges of 0.0036 - 0.073 mg/l, 0.0036 - 1.31 mg/l and 0.0036 - 24.0 mg/l, were applied to drinking therapy, inhalations and balneotherapy, respectively (some of waters analyzed were simultaneously applied to drinking therapy, inhalations and balneotherapy). In the cases of 11 natural curative waters exceeding limit of 1 mg/l were observed, however they were classified mainly as waters applied to balneotherapy and in two cases to inhalation therapies (concentrations of barium - 1.08 mg/l and 1.31 mg/l). The procedure of classification of curative waters for adequate therapies based among other things on barium concentrations meets requirements of the Decree of Minister of Health from 13 April 2006 on the range of studies indispensable for establishing medicinal properties of natural curative materials and curative properties of climate, criteria of their assessment and a specimen of certificate confirmed those properties.

  7. Usefulness of high-density barium for detection of leaks after esophagogastrectomy, total gastrectomy, and total laryngectomy.

    PubMed

    Swanson, Jonathan O; Levine, Marc S; Redfern, Regina O; Rubesin, Stephen E

    2003-08-01

    The purpose of this study was to determine the usefulness of a high-density (250% weight/volume) barium compared with a water-soluble contrast agent for the detection of esophageal leaks in patients who had undergone esophagogastrectomy, total gastrectomy, or total laryngectomy. A search of our radiology database from 1998 to 2001 revealed 46 eligible radiographic studies performed using a water-soluble contrast agent alone or a water-soluble contrast agent followed by barium that showed leaks in patients who had undergone esophagogastrectomy, total gastrectomy, or total laryngectomy. The images were reviewed to determine the morphology of the leaks (i.e., blind-ending tracks, sealed-off collections, or free extravasation of contrast material). Medical records were also reviewed to determine whether detection of the leaks seen on the radiographic studies affected patient management. Of the 46 leaks seen on radiographic studies, 23 (50%) were detected with a water-soluble contrast agent and 23 (50%) were detected only with high-density barium. Of the 23 leaks visualized with water-soluble contrast media, six (26%) were characterized by blind-ending tracks, 14 (61%) by sealed-off collections, and three (13%) by free extravasation of contrast material into the mediastinum or neck. Of the 23 leaks visualized only with high-density barium, 19 (83%) were characterized by blind-ending tracks and four (17%) by sealed-off collections. Thus, leaks detected only on images obtained with high-density barium were significantly more likely to be characterized by blind-ending tracks than those detected on images obtained with a water-soluble contrast agent (p = 0.0007). Of the 33 patients with clinical follow-up, the findings seen on these imaging studies affected management in 12 (86%) of 14 patients with leaks depicted by water-soluble contrast media and in 10 (53%) of 19 with leaks depicted only by high-density barium. Our findings support the use of high-density barium as part of the routine postoperative radiographic examination when no leaks are detected on images obtained with a water-soluble contrast agent.

  8. SEPARATION OF METAL VALUES FROM NUCLEAR REACTOR

    DOEpatents

    Campbell, D.O.; Cathers, G.I.

    1962-06-19

    A method is given for separating beryllium fluoride and an alkali metal fluoride from a mixture containing same and rare earth fluorides. The method comprises contacting said mixture with a liquid hydrogen fluoride solvent containing no more than about 30 per cent water by weight and saturated with a fluoride salt characterized by its solubility in anhydrous hydrogen fluoride for a period of time sufficient to dissolve said beryllium fluoride in said solvent. (AEC)

  9. Thirty years of fluoridation: a review.

    PubMed

    Richmond, V L

    1985-01-01

    Fluoride contributes to stability of both teeth and bones and to reduction of caries, especially if ingested before eruption of teeth. Reduction of caries continues at about 60% in persons drinking fluoridated water only as long as fluoride washes over teeth. One-half the population of the US does not have access to water with an optimal fluoride concentration of about 1 mg/L. Misinformation about fluoridation contributes to reluctance of communities to supplement the natural but inadequate fluoride of those water supplies. Fluoridation of water has no positive or negative effect on incidence or mortality rates due to cancer, heart disease, intracranial lesions, nephritis, cirrhosis, mongoloid births, or from all causes together. The collective decision to increase the natural fluoride content of water supplies is not an infringement of civil rights, nor does it establish a precedent in the binding sense of the law. Supplemental fluoride in water makes it available to all members of the community in a safe, practical, economical and reliable manner. Fluoridation saves money in dental costs and time lost from work. Fluoridation is an appropriate action of government in promoting the health and welfare of society.

  10. Fluoride in groundwater: toxicological exposure and remedies.

    PubMed

    Jha, S K; Singh, R K; Damodaran, T; Mishra, V K; Sharma, D K; Rai, Deepak

    2013-01-01

    Fluoride is a chemical element that is found most frequently in groundwater and has become one of the most important toxicological environmental hazards globally. The occurrence of fluoride in groundwater is due to weathering and leaching of fluoride-bearing minerals from rocks and sediments. Fluoride when ingested in small quantities (<0.5 mg/L) is beneficial in promoting dental health by reducing dental caries, whereas higher concentrations (>1.5 mg/L) may cause fluorosis. It is estimated that about 200 million people, from among 25 nations the world over, may suffer from fluorosis and the causes have been ascribed to fluoride contamination in groundwater including India. High fluoride occurrence in groundwaters is expected from sodium bicarbonate-type water, which is calcium deficient. The alkalinity of water also helps in mobilizing fluoride from fluorite (CaF2). Fluoride exposure in humans is related to (1) fluoride concentration in drinking water, (2) duration of consumption, and (3) climate of the area. In hotter climates where water consumption is greater, exposure doses of fluoride need to be modified based on mean fluoride intake. Various cost-effective and simple procedures for water defluoridation techniques are already known, but the benefits of such techniques have not reached the rural affected population due to limitations. Therefore, there is a need to develop workable strategies to provide fluoride-safe drinking water to rural communities. The study investigated the geochemistry and occurrence of fluoride and its contamination in groundwater, human exposure, various adverse health effects, and possible remedial measures from fluoride toxicity effects.

  11. Chronologic Trends in Studies on Fluoride Mechanisms of Action.

    PubMed

    Oh, H J; Oh, H W; Lee, D W; Kim, C H; Ahn, J Y; Kim, Y; Shin, H B; Kim, C Y; Park, S H; Jeon, J G

    2017-11-01

    Fluoride has been widely used for the prevention of dental caries since the mid-20th century. The aim of this study was to investigate the chronologic trends in studies on fluoride mechanisms of action against dental caries during the years 1950 to 2015. To this aim, queries such as "fluoride," "fluoride and demineralization," "fluoride and remineralization," "fluoride and (plaque or biofilms)," and "fluoride and (bacteria or microbials)" were submitted to PubMed to collect research article information, including titles, abstracts, publication dates, author affiliations, and publication journals. The article information that PubMed produced was then collected by an automatic web crawler and examined through informetrics and linguistic analyses. We found that the number of articles concerned with fluoride mechanisms of action against dental caries was 6,903 and gradually increased over time during the years 1950 to 2015. They were published by 1,136 journals-most notably, Caries Research and Journal of Dental Research. Of the articles published, those related to bacteria/microbials had a higher percentage (44%) than those dealing with plaque/biofilms, demineralization, and remineralization. With regard to the geographic distribution of authors, Europe and North America accounted for 65% of the articles during the years 1987 to 2015, although the number of authors in Asia sharply increased in recent years. Among the fluoride compounds, NaF was mentioned more frequently than SnF 2 , Na 2 PO 3 F, amine fluoride, and acidulated phosphate fluoride during the years 1986 to 2015. Water fluoridation received the most attention among the various fluoride application methods (toothpastes, mouthwashes, fluoride varnishes, and fluoride gels) during the same period. These results, obtained from employing informetrics and linguistic analyses, suggest that in studies on fluoride mechanisms of action, 1) the unbalanced geographic distribution of articles and 2) the heavy concentration of articles on particular fluoride compounds and application methods should be overcome in future research.

  12. 21 CFR 82.3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... hydroxide. (h) The term blanc fixe means a suspension in water of precipitated barium sulfate. (i) The term gloss white means a suspension in water of co-precipitated aluminum hydroxide and barium sulfate. (j...

  13. 21 CFR 82.3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... hydroxide. (h) The term blanc fixe means a suspension in water of precipitated barium sulfate. (i) The term gloss white means a suspension in water of co-precipitated aluminum hydroxide and barium sulfate. (j...

  14. 21 CFR 82.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... hydroxide. (h) The term blanc fixe means a suspension in water of precipitated barium sulfate. (i) The term gloss white means a suspension in water of co-precipitated aluminum hydroxide and barium sulfate. (j...

  15. Fluoride content of infant formulas prepared with deionized, bottled mineral and fluoridated drinking water.

    PubMed

    Buzalaf, M A; Granjeiro, J M; Damante, C A; de Ornelas, F

    2001-01-01

    Usually infant milk formula is the major source of fluoride in infancy. Fluoride concentrations in ten samples of powdered milk formulas, prepared with deionized, bottled mineral, and fluoridated drinking water were determined after HMDS-facilitated diffusion, using a fluoride ion specific electrode(Orion 9609). Fluoride concentrations ranged from 0.01 to 0.75 ppm; from 0.02 to 1.37 ppm and from 0.91 to 1.65 ppm for formulas prepared with deionized, bottled mineral (0.02 to 0.69 ppm F) and fluorinated drinking water (0.9 ppm F), respectively. Possible fluoride ingestion per Kg body mass ws estimated. With deionized water, only the soy-based- formulas should provide a daily fluoride intake of above the suggested threshold for fluorosis. With water containing 0.9 ppm F, however, all of them would provide it. Hence, to limit fluoride intakes to amounts <0.1 mg/kg/day, it is necessary to avoid use fo fluoridated water (around 1 ppm) to dilute powdered infant formulas.

  16. The fractional urinary fluoride excretion of adults consuming naturally and artificially fluoridated water and the influence of water hardness: a randomized trial.

    PubMed

    Villa, A; Cabezas, L; Anabalón, M; Rugg-Gunn, A

    2009-09-01

    To assess whether there was any significant difference in the average fractional urinary fluoride excretion (FUFE) values among adults consuming (NaF) fluoridated Ca-free water (reference water), naturally fluoridated hard water and an artificially (H2SiF6) fluoridated soft water. Sixty adult females (N=20 for each treatment) participated in this randomized, double-blind trial. The experimental design of this study provided an indirect estimation of the fluoride absorption in different types of water through the assessment of the fractional urinary fluoride excretion of volunteers. Average daily FUFE values (daily amount of fluoride excreted in urine/daily total fluoride intake) were not significantly different between the three treatments (Kruskal-Wallis; p = 0.62). The average 24-hour FUFE value (n=60) was 0.69; 95% C.I. 0.65-0.73. The results of this study suggest that the absorption of fluoride is not affected by water hardness.

  17. Does fluoride in the water close the dental caries gap between Indigenous and non-Indigenous children?

    PubMed

    Lalloo, R; Jamieson, L M; Ha, D; Ellershaw, A; Luzzi, L

    2015-09-01

    Indigenous children experience significantly more dental caries than non-Indigenous children. This study assessed if access to fluoride in the water closed the gap in dental caries between Indigenous and non-Indigenous children. Data from four states and two territories were sourced from the Child Dental Health Survey (CDHS) conducted in 2010. The outcomes were dental caries in the deciduous and permanent dentitions, and the explanatory variables were Indigenous status and access to fluoridated water (≥0.5 mg/L) prior to 2008. Dental caries prevalence and severity for Indigenous and non-Indigenous children, in both dentitions, was lower in fluoridated areas compared to non-fluoridated areas. Among non-Indigenous children, there was a 50.9% difference in mean dmft scores in fluoridated (1.70) compared to non-fluoridated (2.86) areas. The difference between Indigenous children in fluoridated (3.29) compared to non-fluoridated (4.16) areas was 23.4%. Among non-Indigenous children there was a 79.7% difference in the mean DMFT scores in fluoridated (0.68) compared to non-fluoridated (1.58) areas. The difference between Indigenous children in fluoridated (1.59) and non-fluoridated (2.23) areas was 33.5%. Water fluoridation is effective in reducing dental caries, but does not appear to close the gap between non-Indigenous children and Indigenous children. © 2015 Australian Dental Association.

  18. Fluoride bioavailability in saliva and plaque

    PubMed Central

    2012-01-01

    Background Different fluoride formulations may have different effects on caries prevention. It was the aim of this clinical study to assess the fluoride content, provided by NaF compared to amine fluoride, in saliva and plaque. Methods Eight trained volunteers brushed their teeth in the morning for 3 minutes with either NaF or amine fluoride, and saliva and 3-day-plaque-regrowth was collected at 5 time intervals during 6 hours after tooth brushing. The amount of collected saliva and plaque was measured, and the fluoride content was analysed using a fluoride sensitive electrode. All subjects repeated all study cycles 5 times, and 3 cycles per subject underwent statistical analysis using the Wilcoxon-Mann-Whitney test. Results Immediately after brushing the fluoride concentration in saliva increased rapidly and dropped to the baseline level after 360 minutes. No difference was found between NaF and amine fluoride. All plaque fluoride levels were elevated after 30 minutes until 120 minutes after tooth brushing, and decreasing after 360 minutes to baseline. According to the highly individual profile of fluoride in saliva and plaque, both levels of bioavailability correlated for the first 30 minutes, and the fluoride content of saliva and plaque was back to baseline after 6 hours. Conclusions Fluoride levels in saliva and plaque are interindividually highly variable. However, no significant difference in bioavailability between NaF and amine fluoride, in saliva, or in plaque was found. PMID:22230722

  19. Gramicidin D enhances the antibacterial activity of fluoride.

    PubMed

    Nelson, James W; Zhou, Zhiyuan; Breaker, Ronald R

    2014-07-01

    Fluoride is a toxic anion found in many natural environments. One of the major bacterial defenses against fluoride is the cell envelope, which limits passage of the membrane-impermeant fluoride anion. Accordingly, compounds that enhance the permeability of bacterial membranes to fluoride should also enhance fluoride toxicity. In this study, we demonstrate that the pore-forming antibiotic gramicidin D increases fluoride uptake in Bacillus subtilis and that the antibacterial activity of this compound is potentiated by fluoride. Polymyxin B, another membrane-targeting antibiotic with a different mechanism of action, shows no such improvement. These results, along with previous findings, indicate that certain compounds that destabilize bacterial cell envelopes can enhance the toxicity of fluoride. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Lower GI Series (Barium Enema)

    MedlinePlus

    ... You may be asked to change position several times to evenly coat the large intestine with the barium. If you are having a double-contrast lower GI series, the radiologist will inject air through the tube ...

  1. Synthesis and Characterization of Iron Doped Nano Barium Titanate Through Mechanochemical Route

    NASA Astrophysics Data System (ADS)

    Mukherjee, Soumya; Ghosh, S.; Ghosh, C.; Mitra, M. K.

    2013-04-01

    Mechanochemical activation was used to prepare Fe doped barium titanate with intense milling in high energy planetary ball mill. Calcination was done at 1250°C for 30 min to obtain BaO, followed by milling with titania, at 400 rpm for 3 and 6 h. Ferric oxide was used for Fe doping. Annealing was done on the milled sample at 650, 750 and 850 °C for 3 and 6 h to generate stoichiometric compound of barium titanate phase. Fe doped barium titanate results in dense cluster of irregular polygonal shape morphology while morphology was spherical in nature for undoped sample. UV-VIS spectra analysis was carried out to determine bandgap (3.93 eV for undoped BT and 3.88 eV for Fe doped BT) followed by emission-excitation of the sample by fluorometric analysis.

  2. Barium Stars and Thermohaline Mixing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Husti, Laura

    2008-01-24

    Barium stars are formed in binary systems through mass transfer from the carbon and s-element rich primary in the AGB phase, to the secondary star which is in a less evolved evolutionary stage. The mixing of the accreted material from the AGB donor with the envelope of the secondary results in a dilution of the s-element abundances. Dilution in red giants is explained by the occurence of the first dredge up, while in case of dwarfs thermohaline mixing would determine it. A comparison between the theoretical predictions of the AGB stellar models and the spectroscopical observations of a large samplemore » of barium stars has been made. Dilution due to thermohaline mixing was taken into account when searching for best fits of the observational data. The importance of thermohaline mixing in barium dwarfs is discussed.« less

  3. DETECTION OF SMALL LESIONS OF THE LARGE BOWEL—Barium Enema Versus Double Contrast

    PubMed Central

    Robinson, J. Maurice

    1954-01-01

    Roentgen study with the so-called opaque barium enema with some modifications is superior to double contrast study as the primary means of demonstrating polyps in the colon as well as other lesions. The method described combines fluoroscopy, high kilovoltage radiography, fluoroscopically aimed “spot films” taken with compression, suction and evacuation studies. In this way unsuspected as well as suspected polyps can be demonstrated, particularly if attention is directed to the region where polyps are most likely to be found—namely, the distal third of the large bowel. Double contrast study is quite valuable as a supplement to the modified “single contrast” barium enema, but it has not been sufficiently perfected to replace the modified opaque barium enema as a primary procedure. In many instances a combination of methods will, of course, be required. PMID:13209360

  4. Observed Barium Emission Rates

    NASA Technical Reports Server (NTRS)

    Stenbaek-Nielsen, H. C.; Wescott, E. M.; Hallinan, T. J.

    1993-01-01

    The barium releases from the CRRES satellite have provided an opportunity for verifying theoretically calculated barium ion and neutral emission rates. Spectra of the five Caribbean releases in the summer of 1991 were taken with a spectrograph on board a U.S. Air Force jet aircraft. Because the line of sight release densities are not known, only relative rates could be obtained. The observed relative rates agree well with the theoretically calculated rates and, together with other observations, confirm the earlier detailed theoretical emission rates. The calculated emission rates can thus with good accuracy be used with photometric observations. It has been postulated that charge exchange between neutral barium and oxygen ions represents a significant source for ionization. If so. it should be associated with emissions at 4957.15 A and 5013.00 A, but these emissions were not detected.

  5. Clinical application of entire gastrointestinal barium meal combined with multi-temporal abdominal films in patients with intestinal neuronal dysplasia type B.

    PubMed

    Li, Xiao-Yun; Li, Xiao-Gang; Du, Ming-Guo; Chen, Zhi-Dan; Tao, Zheng-Gui; Liao, Xiao-Feng

    2013-01-01

    To report and evaluate the application of entire gastrointestinal barium meal combined with multi-temporal abdominal films in the diagnosis of patients with intestinal neuronal dysplasia type B (IND type B). Thirty-six patients with symptoms of long-standing constipation were enrolled in this study. The study took place at the Department of General Surgery, Xiangyang Central Hospital, Hubei Province, China from July 2007 to October 2012. All of them had already been subjected to the tests of barium enema and anorectal manometry and were suspected to be IND type B, but were not confirmed by mucous membrane acetylcholinesterase determination. All underwent the entire gastrointestinal barium meal combined with multi-temporal abdominal films. The data was collected and then analyzed retrospectively. After entire gastrointestinal barium meal combined with multi-temporal abdominal films, 30 out of 36 cases in this group were diagnosed with intestinal neuronal diseases, and then were treated with appropriate surgical treatment. The postoperative pathological diagnosis was IND type B. The other 6 patients in this group still could not be diagnosed explicitly after the test; thus, we treated them with conservative treatment. Entire gastrointestinal barium meal combined with multi-temporal abdominal films has the advantage of being able to test the gastrointestinal transfer capabilities and to find physiological and pathological changes simultaneously. It could provide important proof for the diagnosis of patients with intestinal neuronal dysplasia type B.

  6. Comparative analysis of barium titanate thin films dry etching using inductively coupled plasmas by different fluorine-based mixture gas

    PubMed Central

    2014-01-01

    In this work, the inductively coupled plasma etching technique was applied to etch the barium titanate thin film. A comparative study of etch characteristics of the barium titanate thin film has been investigated in fluorine-based (CF4/O2, C4F8/O2 and SF6/O2) plasmas. The etch rates were measured using focused ion beam in order to ensure the accuracy of measurement. The surface morphology of etched barium titanate thin film was characterized by atomic force microscope. The chemical state of the etched surfaces was investigated by X-ray photoelectron spectroscopy. According to the experimental result, we monitored that a higher barium titanate thin film etch rate was achieved with SF6/O2 due to minimum amount of necessary ion energy and its higher volatility of etching byproducts as compared with CF4/O2 and C4F8/O2. Low-volatile C-F compound etching byproducts from C4F8/O2 were observed on the etched surface and resulted in the reduction of etch rate. As a result, the barium titanate films can be effectively etched by the plasma with the composition of SF6/O2, which has an etch rate of over than 46.7 nm/min at RF power/inductively coupled plasma (ICP) power of 150/1,000 W under gas pressure of 7.5 mTorr with a better surface morphology. PMID:25278821

  7. Barium Tagging n Solid Xenon for nEXO Neutrinoless Double Beta Decay

    NASA Astrophysics Data System (ADS)

    Walton, Tim; Chambers, Chris; Craycraft, Adam; Fairbank, William; nEXO Collaboration

    2015-04-01

    nEXO is a next-generation experiment designed to search for neutrinoless double beta decay of the isotope Xe136 in a liquid xenon time projection chamber. Positive observation of this decay would determine the nature of the neutrino to be a Majorana particle. Since the daughter of this decay is barium (Ba136), detecting the presence of Ba136 at a decay site (called ``barium tagging'') would provide strong rejection of backgrounds in the search for this decay. This would involve detecting a single barium ion from within a macroscopic volume of liquid xenon. This technique may be available for a second phase of the nEXO detector and sensitivity beyond the inverted hierarchy to neutrino oscillations. Several methods of barium tagging are being explored by the nEXO collaboration, but here we present a method of trapping the barium ion/atom (it may neutralize) in solid xenon (SXe) at the end of a cold probe, and then detecting the ion/atom by its fluorescence in the SXe. Our group at CSU has been studying the fluorescence of Ba in SXe by laser excitation, in order to ultimately detect a single Ba +/Ba in a SXe sample. We present studies of fluorescence signals, as well as recent results on imaging small numbers of Ba atoms in SXe, in a focused laser region. This work is supported by grants from the National Science Foundation and the Department of Energy.

  8. Esophageal Transit, Contraction and Perception of Transit After Swallows of Two Viscous Boluses

    PubMed Central

    Dalmazo, Jucileia; Aprile, Lilian Rose Otoboni; Dantas, Roberto Oliveira

    2015-01-01

    Background There have been results showing the influence of bolus viscosities and consistency on esophageal motility and transit. However, there is no description about the influence of two different viscous boluses on esophageal contractions, bolus transit and perception of transit. Our objective in this investigation was to evaluate the esophageal transit and contraction after swallows of two viscous boluses. Methods By impedance and manometric methods, we measured the esophageal transit and contraction after swallows of two viscous boluses of 5 mL volume, 100% barium sulfate and yogurt, swallowed in duplicate in the supine and upright positions. The bolus transit, esophageal contractions and the perception of bolus transit through the esophagus were evaluated in both positions. Impedance and contraction were measured at 5, 10, 15 and 20 cm from the lower esophageal sphincter. After each swallow, the volunteers were asked about the sensation of bolus transit through the esophagus. Results In supine position, the yogurt had a less frequent complete bolus transit than barium. Also in the supine position, the esophageal transit was longer with yogurt than with barium. Esophageal contractions after swallows were similar between barium and yogurt boluses. There was no difference in perception of transit between the two boluses. Conclusion Although both 100% barium sulfate and yogurt are viscous boluses and have similar viscosities, the transit through the esophagus is slower with yogurt bolus than with barium bolus, which suggests that viscosity may be not the sole factor to determine transit. PMID:27785308

  9. The effect on human salivary fluoride concentration of consuming fluoridated salt-containing baked food items.

    PubMed

    Macpherson, L M; Stephen, K W

    2001-10-01

    Salt fluoridation is recognised world-wide as a proven and viable alternative means of consumer choice-related, community-based fluoridation where water fluoridation is either technically or politically impossible. However, as most salt consumed is contained within cooked food products, rather than sprinkled over prepared food at the table, the purpose of this study was to investigate the effects on salivary fluoride concentration of consuming baked food products prepared with 250 and 350 ppm fluoridated salt (as KF). Six food items were baked with (a) normal non-fluoridated salt, (b) 250 mg F/kg salt and (c) 350 mg F/kg salt. Eleven adult volunteers consumed these foodstuffs on separate occasions and salivary samples were collected for fluoride analyses before and at various time points (1-30 min) after eating. For most foodstuffs, small but significant increases in salivary fluoride concentration occurred for at least 5 min after ingestion of the fluoridated salt-containing items. Salivary fluoride concentrations peaked 1 or 2 min after eating, with highest values for the six test foods ranging from 0.16 to 0.25 ppm F, and from 0.18 to 0.44 ppm F for the 250 and 350 mg F/kg salt products, respectively. In all cases, salivary fluoride concentrations had returned to baseline by 20 min. The clinical significance of such small, short-term increases in salivary fluoride is uncertain, but the findings suggest that a more frequent intake of foods with fluoridated salt substituted for normal salt could help sustain slightly elevated salivary fluoride concentrations for more prolonged periods of the day, and might thus potentiate the cariostatic effects of saliva on tooth mineral.

  10. Comparing activated alumina with indigenous laterite and bauxite as potential sorbents for removing fluoride from drinking water in Ghana

    USGS Publications Warehouse

    Craig, Laura; Stillings, Lisa; Decker, David L.; Thomas, James M.

    2015-01-01

    Fluoride is considered beneficial to teeth and bones when consumed in low concentrations, but at elevated concentrations it can cause dental and skeletal fluorosis. Most fluoride-related health problems occur in poor, rural communities of the developing world where groundwater fluoride concentrations are high and the primary sources of drinking water are from community hand-pump borehole drilled wells. One solution to drinking high fluoride water is to attach a simple de-fluoridation filter to the hand-pump; and indigenous materials have been recommended as low-cost sorbents for use in these filters. In an effort to develop an effective, inexpensive, and low-maintenance de-fluoridation filter for a high fluoride region in rural northern Ghana, this study conducted batch fluoride adsorption experiments and potentiometric titrations to investigate the effectiveness of indigenous laterite and bauxite as sorbents for fluoride removal. It also determined the physical and chemical properties of each sorbent. Their properties and the experimental results, including fluoride adsorption capacity, were then compared to those of activated alumina, which has been identified as a good sorbent for removing fluoride from drinking water. The results indicate that, of the three sorbents, bauxite has the highest fluoride adsorption capacity per unit area, but is limited by a low specific surface area. When considering fluoride adsorption per unit weight, activated alumina has the highest fluoride adsorption capacity because of its high specific surface area. Activated alumina also adsorbs fluoride well in a wider pH range than bauxite, and particularly laterite. The differences in adsorption capacity are largely due to surface area, pore size, and mineralogy of the sorbent.

  11. Concentration of Fluoride in Cow's and Buffalo's Milk in Relation to Varying Levels of Fluoride Concentration in Drinking Water of Mathura City in India- A Pilot Study.

    PubMed

    Gupta, Prahlad; Gupta, Nidhi; Meena, Komal; Moon, Ninad Joshirao; Kumar, Puneet; Kaur, Ravneet

    2015-05-01

    To estimate fluoride concentration in drinking water, cow's milk and buffalo's milk and to correlate the concentration of fluoride in cow's milk and buffalo's milk with varying levels of fluoride concentration in drinking water. Ten households having both cows and buffalo's were selected by convenience in each of the 3 zones (below optimum fluoride <0.7 ppm (parts per million), optimum fluoride 0.7-1.2 ppm and above optimum fluoride areas > 1.2 ppm). From these selected households, 200 ml of fresh milk of both cows and buffaloes was collected along with 200 ml of drinking water for estimation of fluoride concentration by using a fluoride ion selective electrode method. The data was analysed using SPSS, version 11.5 for windows. The mean fluoride concentration of drinking water, cow's milk and buffalo's milk in three different fluoride zones was 0.89±0.39, 0.09±0.07, 0.09±0.08 respectively. Pearson's correlation found a statistically significant correlation between fluoride concentrations in cow's and buffalo's milk with varying levels of fluoride concentration in drinking water in zone B and zone C. However, this correlation was not statistically significant in zone A. With an increase in fluoride concentration in drinking water there was an increase in concentration of fluoride in cow's and buffalo's milk. We conclude that this association is seen in conjunction to not only a single factor but rather due to culmination of several other aspects. So, there is a need to elucidate the other factors that might be contributing to this increase and dental fluorosis.

  12. Level of Fluoride in Soil, Grain and Water in Jalgaon District, Maharashtra, India.

    PubMed

    Naik, Rahul Gaybarao; Dodamani, Arun Suresh; Vishwakarma, Prashanth; Jadhav, Harish Chaitram; Khairnar, Mahesh Ravindra; Deshmukh, Manjiri Abhay; Wadgave, Umesh

    2017-02-01

    Fluoride has an influence on both oral as well as systemic health. The major source of fluoride to body is through drinking water as well as through diet. Staple diet mainly depends on local environmental factors, food grains grown locally, its availability etc. Determination of fluoride level in these food grains is important. So, estimation of the amount of fluoride in grains and its relation to the sources of fluoride used for their cultivation viz., soil and water is important. To estimate the relation of fluoride concentration in grains (Jowar) with respect to that of soil and water used for their cultivation. Fifteen samples each of soil, water and grains were collected using standardized method from the same farm fields of randomly selected villages of Jalgaon district. Fluoride ion concentration was determined in laboratory using SPADNS technique. Mean difference in fluoride levels in between the groups were analyzed using ANOVA and Post-Hoc Tukey test. Linear regression method was applied to analyse the association of the fluoride content of grain with water and soil. There was a significant difference in between mean fluoride levels of soil and water (p<0.001) and in between soil and grain (p<0.001); however, difference in between mean fluoride levels of water and grain was found to be non significant (p=0.591). Also fluoride levels in all the three groups showed significant association with each other. Fluoride level of soil, grains and water should be adjusted to an optimum level. Soil has positive correlation with respect to uptake of fluoride by Jowar grains. So, Jowar grains with optimum fluoride content should be made available in the commercial markets so that oral and general health can be benefitted.

  13. Development of resistance of mutans streptococci and Porphyromonas gingivalis to chlorhexidine digluconate and amine fluoride/stannous fluoride-containing mouthrinses, in vitro.

    PubMed

    Kulik, Eva M; Waltimo, Tuomas; Weiger, Roland; Schweizer, Irene; Lenkeit, Krystyna; Filipuzzi-Jenny, Elisabeth; Walter, Clemens

    2015-07-01

    The aim if this study was to determine the minimal inhibitory concentrations of chlorhexidine digluconate and an amine fluoride/stannous fluoride-containing mouthrinse against Porphyromonas gingivalis and mutans streptococci during an experimental long-term subinhibitory exposition. Five P. gingivalis strains and four mutans streptococci were subcultivated for 20-30 passages in subinhibitory concentrations of chlorhexidine digluconate or an amine fluoride/stannous fluoride-containing mouthrinse. Pre-passaging minimal inhibitory concentrations for chlorhexidine ranged from 0.5 to 2 mg/l for mutans streptococci and from 2 to 4 mg/l for the P. gingivalis isolates. For the amine fluoride/stannous fluoride-containing mouthrinse minimal inhibitory values from 0.125 to 0.25% for the mutans streptococci and from 0.063 to 0.125% for the P. gingivalis isolates were determined. Two- to fourfold increased minimal inhibitory concentrations against chlorhexidine were detected for two of the five P. gingivalis isolates, whereas no increase in minimal inhibitory concentrations was found for the mutans streptococci after repeated passaging through subinhibitory concentrations. Repeated exposure to subinhibitory concentrations of the amine fluoride/stannous fluoride-containing mouthrinse did not alter the minimally inhibitory concentrations of the bacterial isolates tested. Chlorhexidine and the amine fluoride/stannous fluoride-containing mouthrinse are effective inhibitory agents against the oral bacterial isolates tested. No general development of resistance against chlorhexidine or the amine fluoride/stannous fluoride-containing mouthrinse was detected. However, some strains showed potential to develop resistance against chlorhexidine after prolonged exposure. The use of chlorhexidine should be limited to short periods of time. The amine fluoride/stannous fluoride-containing mouthrinse appears to have the potential to be used on a long-term basis.

  14. An in situ caries study on the interplay between fluoride dose and concentration in milk.

    PubMed

    Lippert, F; Martinez-Mier, E A; Zero, D T

    2014-07-01

    This randomized, cross-over in situ study investigated the impact of sodium fluoride dose and concentration in milk on caries lesion rehardening, fluoridation and acid resistance. Twenty-eight subjects wore two gauze-covered enamel specimens with preformed lesions placed buccally on their mandibular partial dentures for three weeks. Participants used fluoride-free dentifrice throughout the study and consumed once daily one of the five study treatments: no fluoride in 200 ml milk (0F-200), 1.5 or 3 mg fluoride in either 100 (1.5F-100; 3F-100) or 200 ml milk (1.5F-200; 3F-200). After three weeks, specimens were retrieved. Knoop hardness was used to determine rehardening and resistance to a secondary acid challenge. Enamel fluoride uptake (EFU) was determined using a microbiopsy technique. A linear fluoride dose-response was observed for all study variables which exhibited similar overall patterns. All the treatments resulted in rehardening, with 0F-200 inducing the least and 3F-100 the most. Apart from 1.5F-200, all the treatments resulted in statistically significantly more rehardening compared to 0F-200. The fluoride doses delivered in 100 ml provided directionally although not statistically significantly more rehardening than those delivered in 200 ml milk. EFU data exhibited better differentiation between treatments: all fluoridated milk treatments delivered more fluoride to lesions than 0F-200; fluoride in 100 ml demonstrated statistically significantly higher EFU than fluoride in 200 ml milk. Findings for acid resistance were also more discerning than rehardening data. The present study has provided further evidence for the anti-caries benefits of fluoridated milk. Both fluoride dose and concentration appear to impact the cariostatic properties of fluoride in milk. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Comparison of short-term in vitro fluoride release and recharge from four different types of pit-and-fissure sealants.

    PubMed

    Koga, Hiroshi; Kameyama, Atsushi; Matsukubo, Takashi; Hirai, Yoshito; Takaesu, Yoshinori

    2004-08-01

    The purpose of this in vitro study was to assess the effects of four commercial fluoride-containing pit-and-fissure sealants on caries prevention. Four sealants containing fluoride, Fuji III, Fuji III LC (GC Co., Tokyo), Teethmate F-1 (Kuraray Medical Co., Osaka) and Helioseal F (Vivadent Co., Liechtenstein) were used to investigate fluoride release and recharge. Disk-shaped specimens prepared from each material were immersed in distilled water at a temperature of 37 degrees C. After seven days, acidulated phosphate fluoride solution (APF) was applied to each specimen, and it was then again immersed in distilled water for 14 days. We then determined how much fluoride had been released into the immersing water. Fuji III LC was used with APF solution to investigate the fluoride uptake. Fuji III had the highest fluoride release, and Fuji III LC had the highest fluoride recharge. Helioseal F and Teethmate F-1 had almost no fluoride recharge. Fuji III LC/APF had a higher fluoride uptake to enamel than Fuji III LC. These results suggest that GIC-sealants in the oral cavity can serve as a fluoride reservoir and contribute to retaining a low fluoride level in oral fluids, thereby preventing caries.

  16. Low-levels of fluoride in plaque and saliva and their effects on the demineralisation and remineralisation of enamel; role of fluoride toothpastes.

    PubMed

    Lynch, R J M; Navada, R; Walia, R

    2004-01-01

    To summarise support for current consensus on the likely means by which fluoride toothpastes reduce caries and review some relevant studies of the effect of low levels of fluoride on the demineralisation and remineralisation of enamel. The major anti-caries effect of fluoride toothpastes is thought to result from small but protracted elevations in levels of fluoride in plaque and saliva. Fluoride incorporated into enamel systemically does not reduce enamel solubility sufficiently to exert an anti-caries effect. Fluoride has the potential to exert an anti-caries benefit largely through three mechanisms; inhibition of demineralisation, promotion of remineralisation and interference with bacterial growth and metabolism. However, the low levels of fluoride thought to influence caries are insufficient to have a significant effect via the latter mechanism. Thus reductions in caries resulting from the use of fluoride toothpastes can be linked to modification of the demineralisation/remineralisation balance by direct effects on dental mineral exerted topically by low levels of fluoride. Numerous in vitro studies have shown that low levels of fluoride, typical of those found after many hours in resting plaque and saliva, and resulting from the regular use of fluoride toothpastes, can have a profound effect on enamel demineralisation and remineralisation.

  17. Groundwater fluoride contamination and its possible health implications in Indi taluk of Vijayapura District (Karnataka State), India.

    PubMed

    Ugran, Vidyavati; Desai, Naveen N; Chakraborti, Dipankar; Masali, Kallappa A; Mantur, Prakash; Kulkarni, Shreepad; Deshmukh, Niranjan; Chadchan, Kailash S; Das, Swastika N; Tanksali, Anuradha S; Arwikar, Asha S; Guggarigoudar, Suresh P; Vallabha, Tejaswini; Patil, Shailaja S; Das, Kusal K

    2017-10-01

    Groundwater fluoride concentration and fluoride-related health problems were studied in twenty-two villages of Indi taluk of Vijayapura district, Karnataka, India. Present study (2015) was also used to compare groundwater fluoride concentration in same 22 villages with previous government report (2000). Groundwater fluoride concentrations of 62 bore wells of 22 villages were analyzed by using an ion-sensitive electrode. A total of 660 adults and 600 children were screened for fluorosis symptoms and signs. Sixty clinically suspected fluorosis patients' urine samples were further analyzed for fluoride. The mean value (1.22 ± 0.75 mg/L) of fluoride concentration of 62 bore wells and 54.83 % bore wells with ≥1.0 mg/L of fluoride concentrations in Indi taluk indicates higher than the permissible limit of drinking water fluoride concentration recommended for India. Clinical symptoms like arthritis, joint pains, gastrointestinal discomfort and lower limb deformities with high urinary fluoride concentrations in some subjects suggest fluorosis. Results also showed an increase in groundwater fluoride concentration of the same 22 villages between previous and present study. Preliminary arthritis symptom of the villagers could be due to drinking fluoride-contaminated water. Increase in fluoride concentration with time to the bore wells definitely indicates future danger.

  18. Black Tea Source, Production, and Consumption: Assessment of Health Risks of Fluoride Intake in New Zealand

    PubMed Central

    Godfrey, Michael; Limeback, Hardy

    2017-01-01

    In countries with fluoridation of public water, it is imperative to determine other dietary sources of fluoride intake to reduce the public health risk of chronic exposure. New Zealand has one of the highest per capita consumption rates of black tea internationally and is one of the few countries to artificially fluoridate public water; yet no information is available to consumers on the fluoride levels in tea products. In this study, we determined the contribution of black tea as a source of dietary fluoride intake by measuring the fluoride content in 18 brands of commercially available products in New Zealand. Fluoride concentrations were measured by potentiometric method with a fluoride ion-selective electrode and the contribution of black tea to Adequate Intake (AI) and Tolerable Upper Intake Level (UL) was calculated for a range of consumption scenarios. We examined factors that influence the fluoride content in manufactured tea and tea infusions, as well as temporal changes in fluoride exposure from black tea. We review the international evidence regarding chronic fluoride intake and its association with chronic pain, arthritic disease, and musculoskeletal disorders and provide insights into possible association between fluoride intake and the high prevalence of these disorders in New Zealand. PMID:28713433

  19. Fluoride release from fluoride varnishes under acidic conditions.

    PubMed

    Lippert, F

    2014-01-01

    The aim was to investigate the in vitro fluoride release from fluoride varnishes under acidic conditions. Poly(methyl methacrylate) blocks (Perspex, n=3 per group) were painted with 80 ± 5 mg fluoride varnish (n=10) and placed into artificial saliva for 30 min. Then, blocks were placed into either 1% citric acid (pH 2.27) or 0.3% citric acid (pH 3.75) solutions (n=3 per solution and varnish) for 30 min with the solutions being replaced every 5 min. Saliva and acid solutions were analyzed for fluoride content. Data were analyzed using three-way ANOVA (varnish, solution, time). The three-way interaction was significant (p>0.0001). Fluoride release and release patterns varied considerably between varnishes. Fluoride release in saliva varied by a factor of more than 10 between varnishes. Some varnishes (CavityShield, Nupro, ProFluorid, Vanish) showed higher fluoride release in saliva than during the first 5 min of acid exposure, whereas other varnishes (Acclean, Enamel-Pro, MI Varnish, Vella) showed the opposite behavior. There was little difference between acidic solutions. Fluoride release from fluoride varnishes varies considerably and also depends on the dissolution medium. Bearing in mind the limitations of laboratory research, the consumption of acidic drinks after fluoride varnish application should be avoided to optimize the benefit/risk ratio.

  20. Urinary fluoride as a monitoring tool for assessing successful intervention in the provision of safe drinking water supply in five fluoride-affected villages in Dhar district, Madhya Pradesh, India.

    PubMed

    Srikanth, R; Gautam, Anil; Jaiswal, Suresh Chandra; Singh, Pavitra

    2013-03-01

    Endemic fluorosis was detected in 31 villages in the Dhar district of Madhya Pradesh, Central India. Out of the 109 drinking water sources that were analyzed, about 67 % were found to contain high concentration of fluoride above the permissible level of 1.0 mg/l. Dental fluorosis among the primary school children in the age between 8 and 15 served as primary indicator for fluoride intoxication among the children. Urinary fluoride levels among the adults were found to be correlated with drinking water fluoride in 10 villages affected by fluoride. Intervention in the form of alternate safe water supply in five villages showed significant reduction in the urinary fluoride concentration when compared to the control village. Urinary fluoride serves as an excellent marker for assessing the effectiveness of intervention program in the fluoride-affected villages.

  1. Isothermal vapor-liquid equilibria for the systems 1-chloro-1,1-difluoroethane + hydrogen fluoride, 1,1-dichloro-1-fluoroethane + hydrogen fluoride, and chlorodifluoromethane + hydrogen fluoride

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Y.W.; Lee, Y.Y.

    1997-03-01

    Isothermal vapor-liquid equilibria for the three binary systems (1-chloro-1,1-difluoroethane + hydrogen fluoride, 1,1-dichloro-1-fluoroethane + hydrogen fluoride, and chlorodifluoromethane + hydrogen fluoride) have been measured. The experimental data for the binary systems are correlated with the NRTL equation with the vapor-phase association model for the mixtures containing hydrogen fluoride, and the relevant parameters are presented. All of the systems form minimum boiling heterogeneous azeotropes.

  2. Community effectiveness of public water fluoridation in reducing children's dental disease.

    PubMed

    Armfield, Jason Mathew

    2010-01-01

    Water fluoridation is one of the most effective public health programs of the past century. However, efforts to extend water fluoridation into currently non-fluoridated areas are often thwarted. Despite considerable evidence regarding the effectiveness of water fluoridation at an individual level, published national community-based studies are rare. This study compared children's decay experience and prevalence between areas with and without water fluoridation in Australia. Oral health data were obtained from clinical examinations of 128, 990 5- to 15-year-old children attending for a regular visit with their respective Australian state or territory School Dental Service in 2002. Water fluoridation status, residence remoteness, and socioeconomic status (SES) were obtained for each child's recorded residential postcode area. Children from every age group had greater caries prevalence and more caries experience in areas with negligible fluoride concentrations in the water (<0.3 parts per million [ppm]) than in optimally fluoridated areas (> or = 0.7 ppm). Controlling for child age, residential location, and SES, deciduous and permanent caries experience was 28.7% and 31.6% higher, respectively, in low-fluoride areas compared with optimally fluoridated areas. The odds ratios for higher caries prevalence in areas with negligible fluoride compared with optimal fluoride were 1.34 (95% confidence interval [CI] 1.29, 1.39) and 1.24 (95% CI 1.21, 1.28) in the deciduous and permanent dentitions, respectively. This study demonstrates the continued community effectiveness of water fluoridation and provides support for the extension of this important oral health intervention to populations currently without access to fluoridated water.

  3. Fluoride-releasing restorative materials and secondary caries.

    PubMed

    Hicks, John; Garcia-Godoy, Franklin; Donly, Kevin; Flaitz, Catherine

    2003-03-01

    Secondary caries is responsible for 60 percent of all replacement restorations in the typical dental practice. Risk factors for secondary caries are similar to those for primary caries development. Unfortunately, it is not possible to accurately predict which patients are at risk for restoration failure. During the past several decades, fluoride-releasing dental materials have become a part of the dentist's armamentarium. Considerable fluoride is released during the setting reaction and for periods up to eight years following restoration placement. This released fluoride is readily taken up by the cavosurface tooth structure, as well as the enamel and root surfaces adjacent to the restoration. Resistance against caries along the cavosurface and the adjacent smooth surface has been shown in both in vitro and in vivo studies. Fluoride-releasing dental materials provide for improved resistance against primary and secondary caries in coronal and root surfaces. Plaque and salivary fluoride levels are elevated to a level that facilitates remineralization. In addition, the fluoride released to dental plaque adversely affects the growth of lactobacilli and mutans streptococci by interference with bacterial enzyme systems. Fluoride recharging of these dental materials is readily achieved with fluoridated toothpastes, fluoride mouthrinses, and other sources of topical fluoride. This allows fluoride-releasing dental materials to act as intraoral fluoride reservoirs. The improvement in the properties of dental materials with the ability to release fluoride has improved dramatically in the past decade, and it is anticipated that in the near future the vast majority of restorative procedures will employ fluoride-releasing dental materials as bonding agents, cavity liners, luting agents, adhesives for orthodontic brackets, and definitive restoratives.

  4. Prevalence of fluorosis and identification of fluoride endemic areas in Manur block of Tirunelveli District, Tamil Nadu, South India

    NASA Astrophysics Data System (ADS)

    Gopalakrishnan, Subarayan Bothi; Viswanathan, Gopalan; Siva Ilango, S.

    2012-12-01

    Prevalence of fluorosis is mainly due to the consumption of more fluoride through drinking water. It is necessary to identify the fluoride endemic areas to adopt remedial measures for the people under the risk of fluorosis. The objectives of this study were to identify the exact location of fluoride endemic areas in Manur block of Tirunelveli District and to estimate fluoride exposure level through drinking water for different age groups. Identification of fluoride endemic areas was performed through Isopleth and Google earth mapping techniques. Fluoride level in drinking water samples was estimated by fluoride ion selective electrode method. A systematic clinical survey conducted in 19 villages of Manur block revealed the rate of prevalence of fluorosis. From this study, it has been found that Alavanthankulam, Melapilliyarkulam, Keezhapilliyarkulam, Nadupilliyarkulam, Keezhathenkalam and Papankulam are the fluoride endemic villages, where the fluoride level in drinking water is above 1 mg/l. Consumption of maximum fluoride exposure levels of 0.30 mg/kg/day for infants, 0.27 mg/kg/day for children and 0.15 mg/kg/day for adults were found among the respective age group people residing in high fluoride endemic area. As compared with adequate intake level of fluoride of 0.01 mg/kg/day for infants and 0.05 mg/kg/day for other age groups, the health risk due to excess fluoride intake to the people of Alavanthankulam and nearby areas has become evident. Hence the people of these areas are advised to consume drinking water with optimal fluoride to avoid further fluorosis risks.

  5. In Vitro Inhibition of Enamel Demineralisation by Fluoride-releasing Restorative Materials and Dental Adhesives.

    PubMed

    Dionysopoulos, Dimitrios; Koliniotou-Koumpia, Eugenia; Helvatzoglou-Antoniades, Maria; Kotsanos, Nikolaos

    2016-01-01

    To determine the ability of 5 contemporary fluoride-releasing restoratives and 3 fluoride-releasing adhesives to inhibit enamel demineralisation surrounding restorations, and the associations between inhibition and the levels of fluoride released from these materials. Five fluoride-releasing restoratives (Fuji IX GP, Ketac N100, Dyract Extra, Beautifil II and Wave) and 3 fluoride-releasing adhesives (Stae, Prime & Bond NT and Fluoro Bond II) were investigated. Eight disks of each material were prepared. Fluoride release was measured daily using a fluoride-ion-selective electrode for 15 days. Twenty-four cavities for each group were restored with a restorative and an adhesive. Specimens were subjected to thermal stress and stored for 30 days in saline solution. After a 15-day pH-cycling regimen, two 150-μm-thick sections were derived from each specimen. Enamel lesion depth was measured at 0, 100, and 200 μm from each restoration's margin via polarised light microscopy. Of the restoratives investigated, Fuji IX GP released the most fluoride. The fluoride-releasing restoratives tested exhibited shallower enamel lesions than did the control group at all distances tested (p < 0.05). Fuji IX GP yielded significantly lower enamel lesion depth than did the other experimental materials. The depths of enamel lesions did not differ significantly when comparing restoratives applied with a fluoride-releasing adhesive with those applied with a non-fluoride-releasing adhesive. The fluoride-releasing materials tested reduced enamel demineralisation but to different extents, depending on their levels of fluoride release. Fluoride-releasing adhesives did not influence enamel lesion formation.

  6. Alimentary fluoride intake in preschool children

    PubMed Central

    2011-01-01

    Background The knowledge of background alimentary fluoride intake in preschool children is of utmost importance for introducing optimal and safe caries preventive measures for both individuals and communities. The aim of this study was to assess the daily fluoride intake analyzing duplicate samples of food and beverages. An attempt was made to calculate the daily intake of fluoride from food and swallowed toothpaste. Methods Daily alimentary fluoride intake was measured in a group of 36 children with an average age of 4.75 years and an average weight of 20.69 kg at baseline, by means of a double plate method. This was repeated after six months. Parents recorded their child's diet over 24 hours and collected duplicated portions of food and beverages received by children during this period. Pooled samples of food and beverages were weighed and solid food samples were homogenized. Fluoride was quantitatively extracted from solid food samples by a microdiffusion method using hexadecyldisiloxane and perchloric acid. The content of fluoride extracted from solid food samples, as well as fluoride in beverages, was measured potentiometrically by means of a fluoride ion selective electrode. Results Average daily fluoride intake at baseline was 0.389 (SD 0.054) mg per day. Six months later it was 0.378 (SD 0.084) mg per day which represents 0.020 (SD 0.010) and 0.018 (SD 0.008) mg of fluoride respectively calculated per kg bw/day. When adding the values of unwanted fluoride intake from the toothpaste shown in the literature (0.17-1.21 mg per day) the estimate of the total daily intake of fluoride amounted to 0.554-1.594 mg/day and recalculated to the child's body weight to 0.027-0.077 mg/kg bw/day. Conclusions In the children studied, observed daily fluoride intake reached the threshold for safe fluoride intake. When adding the potential fluoride intake from swallowed toothpaste, alimentary intake reached the optimum range for daily fluoride intake. These results showed that in preschool children, when trying to maximize the benefit of fluoride in caries prevention and to minimize its risk, caution should be exercised when giving advice on the fluoride containing components of child's diet or prescribing fluoride supplements. PMID:21974798

  7. Distribution and source of barium in ground water at Cattaraugus Indian Reservation, southwestern New York

    USGS Publications Warehouse

    Moore, R.B.; Staubitz, W.W.

    1984-01-01

    High concentrations of dissolved barium have been found in ground water from bedrock wells on the Seneca Nation of Indians Reservation on Cattaraugus Creek in southwestern New York. Concentrations in 1982 were as high as 23.0 milligrams per liter , the highest found reported from any natural ground-water system in the world. The highest concentrations are in a bedrock aquifer and in small lenses of saturated gravel between bedrock and the overlying till. The bedrock aquifer is partly confined by silt, clay, and till. The high barium concentrations are attributed to dissolution of the mineral barite (BaSO4), which is present in the bedrock and possibly in overlying silt, clay, or till. The dissolution of barite seems to be controlled by action of sulfate-reducing bacteria, which alter the BaSO4 equilibrium by removing sulfate ions and permitting additional barite to dissolve. Ground water from the surficial, unconsolidated deposits and surface water in streams contain little or no barium. Because barium is chemically similar to calcium, it probably could be removed by cation exchange or treatments similar to those used for water softening. (USGS)

  8. Microcapsules with Intrinsic Barium Radiopacity for Immunoprotection and X-ray/CT imaging of Pancreatic Islet Cells

    PubMed Central

    Arifin, D.R.; Manek, S.; Call, E.; Arepally, A.; Bulte, J.W.M.

    2012-01-01

    Microencapsulation is a commonly used technique for immunoprotection of engrafted therapeutic cells. We investigated a library of capsule formulations to determine the most optimal formulation for pancreatic beta islet cell transplantation, using barium as the gelating ion and clinical-grade protamine sulfate (PS) as a new cationic capsule cross-linker. Barium-gelated alginate/PS/alginate microcapsules (APSA, diameter = 444±21 μm) proved to be mechanically stronger and supported a higher cell viability as compared to conventional alginate/poly-L-lysine/alginate (APLLA) capsules. Human pancreatic islets encapsulated inside APSA capsules, gelated with 20 mM barium as optimal concentration, exhibited a sustained morphological integrity, viability, and functionality for at least 3–4 weeks in vitro, with secreted human C-peptide levels of 0.2–160 pg/ml/islet. Unlike APLLA capsules that are gelled with calcium, barium-APSA capsules are intrinsically radiopaque and, when engrafted into mice, could be readily imaged in vivo with micro-computed tomography (CT). Without the need of adding contrast agents, these capsules offer a clinically applicable alternative for simultaneous immunoprotection and real-time, non-invasive X-ray/CT monitoring of engrafted cells during and after in vivo administration. PMID:22444642

  9. Regeneration of barium carbonate from barium sulphide in a pilot-scale bubbling column reactor and utilization for acid mine drainage.

    PubMed

    Mulopo, J; Zvimba, J N; Swanepoel, H; Bologo, L T; Maree, J

    2012-01-01

    Batch regeneration of barium carbonate (BaCO(3)) from barium sulphide (BaS) slurries by passing CO(2) gas into a pilot-scale bubbling column reactor under ambient conditions was used to assess the technical feasibility of BaCO(3) recovery in the Alkali Barium Calcium (ABC) desalination process and its use for sulphate removal from high sulphate Acid Mine Drainage (AMD). The effect of key process parameters, such as BaS slurry concentration and CO(2) flow rate on the carbonation, as well as the extent of sulphate removal from AMD using the recovered BaCO(3) were investigated. It was observed that the carbonation reaction rate for BaCO(3) regeneration in a bubbling column reactor significantly increased with increase in carbon dioxide (CO(2)) flow rate whereas the BaS slurry content within the range 5-10% slurry content did not significantly affect the carbonation rate. The CO(2) flow rate also had an impact on the BaCO(3) morphology. The BaCO(3) recovered from the pilot-scale bubbling column reactor demonstrated effective sulphate removal ability during AMD treatment compared with commercial BaCO(3).

  10. Synthesis and surface properties of submicron barium sulfate particles

    NASA Astrophysics Data System (ADS)

    Zhang, Ming; Zhang, Bao; Li, Xinhai; Yin, Zhoulan; Guo, Xueyi

    2011-10-01

    Barium sulfate particles were synthesized in the presence of EDTA at room temperature. X-ray diffractometry (XRD), Fourier transform infrared resonance (FTIR) and scanning electron microscopy (SEM) were used to characterize the structure and morphology of BaSO 4 particles. The effect of the preparation parameters on the particle size distribution and morphology was investigated. The conditional formation constants of Ba-EDTA at different pH values were calculated. The results show that the size and morphology of BaSO 4 particles can be effectively controlled by adding EDTA in the precipitation process. Among all the operation conditions, the pH value has significant effect on the particle size. The obtained barium sulfate particles are spherical and well dispersed at pH = 9-10. Zeta potentials of BaSO 4 were measured at different pH. The isoelectric point (IEP) of barium sulfate colloid appears at pH 6.92. The model of the solid-solution interface at a particle of BaSO 4 was presented. The FTIR result indicates that the surface of the prepared BaSO 4 absorbs the functional groups of EDTA, which lower the IEP of the barium sulfate particles.

  11. Effects of oral doses of fluoride on nestling European starlings

    USGS Publications Warehouse

    Fleming, W.J.; Grue, C.E.; Schuler, C.A.; Bunck, C.M.

    1987-01-01

    Nestling European starlings (Sturnus vulgaris), raised and fed by free-living adults, were given daily oral doses of either distilled water, 193 mg sodium as Na2CO3 per kg of body weight (sodium control group), or 6, 10, 13, 17,23, 30, 40, 80, 160 mg of the fluoride ion as NaF in distilled water per kg of body weight (mg/kg). Dosing began when nestlings were 24-48 hr old and continued for 16 days. The 24-hr LD50 of fluoride for day-old starlings was 50 mg/kg. The 16-day LD50 was 17 mg/kg. The sodium control group did not differ from the water control group with respect to any of the measured variables. Growth rates were significantly reduced in the 13 and 17 mg of fluoride/kg groups; weights of birds given higher dose levels were omitted from growth comparisons because of high, fluoride-induced mortality. Although pre-fledging weights for the 10, 13, and 17 mg of fluoride/kg groups averaged 3.6 to 8.6% less than controls at 17 days, this difference was not significant. Feather and bone growth of the fluoride and control groups were not different, except for keel length measured at 17 days of age which averaged less in the fluoride groups. Liver and spleen weights were not affected by fluoride treatments. No histological damage related to fluoride treatments was found in liver, spleen, or kidney. The logarithm of bone fluoride and magnesium concentration increased with the logarithm of increasing fluoride treatment levels and were significantly correlated with each other. Fluoride treatments had no effect on percent calcium or phosphorus in bone or plasma alkaline phosphatase activity. Oral doses of fluoride appear to be more toxic than equivalent dietary levels. Most birds probably acquire fluoride through their diet. Therefore, the results of the study may overestimate the potential effects of fluorides on songbirds living in fluoride-contaminated environments.

  12. PTH (1-34) affects bone turnover governed by osteocytes exposed to fluoride.

    PubMed

    Yu, Xiuhua; Yu, Haolan; Jiang, Ningning; Zhang, Xiuyun; Zhang, Mengmeng; Xu, Hui

    2018-05-15

    Exposure to fluoride from environmental sources remains an overlooked, but serious public health risk. In this study, we looked into the role osteocytes play on the mechanism underlying fluoride induced osteopathology. We analyzed bone formation and resorption related genes generated by osteocytes that were exposed to varied doses of fluoride with and without PTH in vitro. Correspondingly, osteogenesis and osteoclastogenesis related genes were also investigated in rats exposed to fluoride for 8 weeks, and the PTH(1-34)was applied at the last 3 weeks to observe its role in regulating bone turnover upon fluoride treatment. The data in vitro indicated that fluoride treatment inhibited Sost expression of mRNA and protein and stimulated RANKL mRNA protein expression as well as the RANKL/OPG ratio in the primary osteocytes. Single PTH treatment played the similar role on expression of these genes and proteins. The PTH combined administration enhanced the action of fluoride treatment on RNAKL/OPG and SOST/Sclerostin. The up-regulation of RANKL and decreasing of Sost induced by fluoride and/or PTH treatment was validated in vivo and suggests that osteocytes are a major source of RANKL and Sost, both of which play essential roles in fluoride affecting osteogenesis and osteoclastogenesis. Expression of Wnt/β-catenin was up-regulated in both in vitro osteocytes treated with high dose of fluoride and bone tissue of rats in the presence of fluoride and PTH. In vivo, fluoride and single PTH stimulated bone turnover respectively, furthermore, PTH combined with low dose of fluoride treatment reinforced the osteogenesis and osteoclastogenesis genes expression, however, co-treatment of PTH reversed the effect of high dose of fluoride on osteogenesis and osteoclastogenensis related factors. In conclusion, this study demonstrated that osteocytes play a key role in fluoride activated bone turnover, and PTH participates in the process of fluoride modulating SOST/Sclerostin and RANKL expression. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Barium Isotopes in Single Presolar Grains

    NASA Technical Reports Server (NTRS)

    Pellin, M. J.; Davis, A. M.; Savina, M. R.; Kashiv, Y.; Clayton, R. N.; Lewis, R. S.; Amari, S.

    2001-01-01

    Barium isotopic compositions of single presolar grains were measured by laser ablation laser resonant ionization mass spectrometry and the implications of the data for stellar processes are discussed. Additional information is contained in the original extended abstract.

  14. Effect of exercise on fluoride metabolism in adult humans: a pilot study.

    PubMed

    V Zohoori, Fatemeh; Innerd, Alison; Azevedo, Liane B; Whitford, Gary M; Maguire, Anne

    2015-11-19

    An understanding of all aspects of fluoride metabolism is critical to identify its biological effects and avoid fluoride toxicity in humans. Fluoride metabolism and subsequently its body retention may be affected by physiological responses to acute exercise. This pilot study investigated the effect of exercise on plasma fluoride concentration, urinary fluoride excretion and fluoride renal clearance following no exercise and three exercise intensity conditions in nine healthy adults after taking a 1-mg Fluoride tablet. After no, light, moderate and vigorous exercise, respectively, the mean (SD) baseline-adjusted i) plasma fluoride concentration was 9.6(6.3), 11.4(6.3), 15.6(7.7) and 14.9(10.0) ng/ml; ii) rate of urinary fluoride excretion over 0-8 h was 46(15), 44(22), 34(17) and 36(17) μg/h; and iii) rate of fluoride renal clearance was 26.5(9.0), 27.2(30.4), 13.1(20.4) and 18.3(34.9) ml/min. The observed trend of a rise in plasma fluoride concentration and decline in rate of fluoride renal clearance with increasing exercise intensity needs to be investigated in a larger trial. This study, which provides the first data on the effect of exercise with different intensities on fluoride metabolism in humans, informs sample size planning for any subsequent definitive trial, by providing a robust estimate of the variability of the effect.

  15. Fluoride metabolism.

    PubMed

    Buzalaf, Marília Afonso Rabelo; Whitford, Gary Milton

    2011-01-01

    Knowledge of all aspects of fluoride metabolism is essential for comprehending the biological effects of this ion in humans as well as to drive the prevention (and treatment) of fluoride toxicity. Several aspects of fluoride metabolism - including gastric absorption, distribution and renal excretion - are pH-dependent because the coefficient of permeability of lipid bilayer membranes to hydrogen fluoride (HF) is 1 million times higher than that of F(-). This means that fluoride readily crosses cell membranes as HF, in response to a pH gradient between adjacent body fluid compartments. After ingestion, plasma fluoride levels increase rapidly due to the rapid absorption from the stomach, an event that is pH-dependent and distinguishes fluoride from other halogens and most other substances. The majority of fluoride not absorbed from the stomach will be absorbed from the small intestine. In this case, absorption is not pH-dependent. Fluoride not absorbed will be excreted in feces. Peak plasma fluoride concentrations are reached within 20-60 min following ingestion. The levels start declining thereafter due to two main reasons: uptake in calcified tissues and excretion in urine. Plasma fluoride levels are not homeostatically regulated and vary according to the levels of intake, deposition in hard tissues and excretion of fluoride. Many factors can modify the metabolism and effects of fluoride in the organism, such as chronic and acute acid-base disturbances, hematocrit, altitude, physical activity, circadian rhythm and hormones, nutritional status, diet, and genetic predisposition. These will be discussed in detail in this review. Copyright © 2011 S. Karger AG, Basel.

  16. Optical super-resolution and periodical focusing effects by dielectric microspheres

    NASA Astrophysics Data System (ADS)

    Darafsheh, Arash

    Optical microscopy is one of the oldest and most important imaging techniques; however, its far-field resolution is diffraction-limited. In this dissertation, we proposed and developed a novel method of optical microscopy with super-resolution by using high-index dielectric microspheres immersed in liquid and placed on the surface of the structures under study. We used barium titanate glass microspheres with diameters of D~2-220 mum and refractive indices n˜1.9-2.1 to discern minimal feature sizes ˜lambda/4 (down to ˜lambda/7) of various photonic and plasmonic nanostructures, where lambda is the illumination wavelength. We studied the magnification, field of view, and resolving power, in detail, as a function of sphere sizes. We studied optical coupling, transport, focusing, and polarization properties of linear arrays of dielectric spheres. We showed that in arrays of spheres with refractive index n=3, a special type of rays with transverse magnetic (TM) polarization incident on the spheres under the Brewster's angle form periodically focused modes with radial polarization and 2D period, where D is the diameter of the spheres. We showed that the formation of periodically focused modes in arrays of dielectric spheres gives a physical explanation for beam focusing and extraordinarily small attenuation of light in such chains. We showed that the light propagation in such arrays is strongly polarization-dependent, indicating that such arrays can be used as filters of beams with radial polarization. The effect of forming progressively smaller focused beams was experimentally observed in chains of sapphire spheres in agreement with the theory. We studied optical coupling,transport, focusing, and polarization properties of linear arrays of dielectric spheres. We showed that in arrays of spheres with refractive index n=a3, a special type of rays with transverse magnetic (TM) polarization incident on the spheres under the Brewster's angle form periodically focused modes with radial polarization and 2D period, where D is the diameter of the spheres. We showed that the formation of periodically focused modes in arrays of dielectric spheres gives a physical explanation for beam focusing and extraordinarily small attenuation of light in such chains. We showed that the light propagation in such arrays is strongly polarization-dependent, indicating that such arrays can be used as filters of beams with radial polarization. The effect of forming progressively smaller focused beams was experimentally observed in chains of sapphire spheres in agreement with the theory.

  17. [Fluoridation of drinking water, why is it needed?].

    PubMed

    Zusman, S P; Natapov, L; Ramon, T

    2004-01-01

    Dental caries is a widespread disease. It causes irreversible damage, pain and considerable expense. Fluoride is the only known substance that raises the tooth's resistance to acid attack. Natural drinking waters contain fluoride at different concentration. The most effective method of fluoride administration to the community level is by adjustng the fluoride concentration in the drinking water to about 1 part per million. To describe the mode of action of fluoride, methods of administration and to describe water fluoridation, advantages and disadvantages. Fluoridation of drinking water started in 1945 in the world and in 1981 in Israel. Today more then 300 million people in some 60 countries enjoy the defending effect of fluoride in drinking water. This is the most effective method for decreasing incidence of caries, as well as being cost effective. Over the years there were many attempts to 'blame' fluoridation with negative side effects to human health. Till today, none of the allegations passed scientific scrutiny. There is overwhelming scientific support for the Regulations that oblige the Water supplier to adjust fluoride levels to 1 ppm in every town or municipality with more then 5,000 inhabitants.

  18. Community water fluoridation on the Internet and social media.

    PubMed

    Mertz, Aaron; Allukian, Myron

    2014-01-01

    In the United States, 95 percent of teens and 85 percent of adults use the Internet. Two social media outlets, Facebook and Twitter, reach more than 150 billion users. This study describes anti-fluoridation activity and dominance on the Internet and social media, both of which are community water fluoridation (CWF) information sources. Monthly website traffic to major fluoridation websites was determined from June 2011 to May 2012. Facebook, Twitter, and YouTube fluoridation activity was categorized as "proCWF" or "anti-CWF." Twitter's anti-CWF tweets were further subcategorized by the argument used against CWF. Anti-CWF website traffic was found to exceed proCWF activity five- to sixty-fold. Searching "fluoride" and "fluoridation" on Facebook resulted in 88 to 100 percent anti-CWF groups and pages; "fluoridation" on Twitter and YouTube resulted in 64 percent anti-CWF tweets and 99 percent anti-CWF videos, respectively. "Cancer, " "useless, " and "poisonous" were the three major arguments used against fluoridation. Anti-fluoridation information significantly dominates the Internet and social media. Thousands of people are being misinformed daily about the safety, health, and economic benefits of fluoridation.

  19. The Impact of Fluoride on Ameloblasts and the Mechanisms of Enamel Fluorosis

    PubMed Central

    Bronckers, A.L.J.J.; Lyaruu, D.M.; DenBesten, P.K.

    2009-01-01

    Intake of excess amounts of fluoride during tooth development cause enamel fluorosis, a developmental disturbance that makes enamel more porous. In mild fluorosis, there are white opaque striations across the enamel surface, whereas in more severe cases, the porous regions increase in size, with enamel pitting, and secondary discoloration of the enamel surface. The effects of fluoride on enamel formation suggest that fluoride affects the enamel-forming cells, the ameloblasts. Studies investigating the effects of fluoride on ameloblasts and the mechanisms of fluorosis are based on in vitro cultures as well as animal models. The use of these model systems requires a biologically relevant fluoride dose, and must be carefully interpreted in relation to human tooth formation. Based on these studies, we propose that fluoride can directly affect the ameloblasts, particularly at high fluoride levels, while at lower fluoride levels, the ameloblasts may respond to local effects of fluoride on the mineralizing matrix. A new working model is presented, focused on the assumption that fluoride increases the rate of mineral formation, resulting in a greater release of protons into the forming enamel matrix. PMID:19783795

  20. Preparation and characterization of antimony barium composite oxide photocatalysts

    NASA Astrophysics Data System (ADS)

    Han, X. P.; Yao, B. H.; Pan, Q. H.; Pen, C.; Zhang, C. L.

    2018-01-01

    In this paper, two kinds of antimony barium composite oxide photocatalysts have been prepared by two methods and characterized by XRD and SEM. The photocatalytic activity was evaluated by a photocatalytic reactor and an ultraviolet spectrophotometer. The results showed that-BaSb2O5•4H2O, BaSb2O6 two kinds of antimony barium composite oxide photocatalysts were successfully prepared in this experiment and they showed good photocatalytic properties. In addition, BaSb2O6 morphology showed more regular, microstructure and better catalytic performance.

  1. Elevated Z line: a new sign of Barrett's esophagus on double-contrast barium esophagograms.

    PubMed

    Levine, Marc S; Ahmad, Nuzhat A; Rubesin, Stephen E

    2015-01-01

    We describe an elevated Z line as a new radiographic sign of Barrett's esophagus characterized by a transversely oriented, zigzagging, barium-etched line extending completely across the circumference of the midesophagus. An elevated Z line is rarely seen in other patients, so this finding should be highly suggestive of Barrett's esophagus on double-contrast barium esophagograms. If the patient is a potential candidate for surveillance, endoscopy and biopsy should be performed to confirm the presence of Barrett's esophagus. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Study of the photovoltaic effect in thin film barium titanate

    NASA Technical Reports Server (NTRS)

    Grannemann, W. W.; Dharmadhikari, V. S.

    1981-01-01

    The photoelectric effect in structures consisting of metal deposited barium titanate film silicon is described. A radio frequency sputtering technique is used to deposit ferroelectric barium titantate films on silicon and quartz. Film properties are measured and correlated with the photoelectric effect characteristics of the films. It was found that to obtain good quality pin hole free films, it is necessary to reduce the substrate temperature during the last part of the deposition. The switching ability of the device with internal applied voltage is improved when applied with a ferroelectric memory device.

  3. Ionization and expansion of barium clouds in the ionosphere

    NASA Technical Reports Server (NTRS)

    Ma, T.-Z.; Schunk, R. W.

    1993-01-01

    A recently envelope 3D model is used here to study the motion of the barium clouds released in the ionosphere, including the ionization stage. The ionization and the expansion of the barium clouds and the interaction between the clouds and the background ions are investigated using three simulations: a cloud without a directional velocity, a cloud with an initial velocity of 5 km/s across the B field, and a cloud with initial velocity components of 2 km/s both along and across the B field.

  4. ION-EXCHANGE METHOD FOR SEPARATING RADIUM FROM RADIUM-BARIUM MIXTURES

    DOEpatents

    Fuentevilla, M.E.

    1959-06-30

    An improved process is presented for separating radium from an aqueous feed solution containing radium and barium values and a complexing agent for these metals. In this process a feed solutlon containing radium and barium ions and a complexing agent for said ions ls cycled through an exchange zone in resins. The radiumenriched resin is then stripped of radium values to form a regeneration liquid, a portion of which is collected as an enriched product, the remaining portion being recycled to the exchange zone to further enrich the ion exchange resin in radium.

  5. Meteorological support to the West German-United States Barium Ion Cloud Project.

    NASA Technical Reports Server (NTRS)

    Westfall, R. R.; Chamberlain, L. W.

    1972-01-01

    The objective of the Barium Ion Cloud Project was to study a barium ionized cloud released at an altitude of 5 earth radii. Accurate forecasting of weather conditions to prevail during the experiment period was critical to the project success. Good seeing conditions were required at all optical sites during the experiment. All meteorological support was the responsibility of the National Weather Service at Wallops Station, Virginia. Preliminary results confirm the scientists' theories of the magnetic fields and the existence of electric fields in the magnetosphere.

  6. Mössbauer and X-ray diffraction study of Co2+-Si4+ substituted M-type barium hexaferrite BaFe12-2хСохSiхO19±γ

    NASA Astrophysics Data System (ADS)

    Solovyova, E. D.; Pashkova, E. V.; Ivanitski, V. P.; V‧yunov, O. I.; Belous, A. G.

    2013-03-01

    Using X-ray powder diffractions, Mössbauer spectroscopy, and magnetic measurements, the effect of dopants (Co2++Si4+) on the fine structure and magnetic properties of M-type barium hexaferrite prepared by hydroxide and carbonate precipitations has been studied. It has been shown that the magnetic properties of M-type barium hexaferrite can be controlled by heterovalent substitution 2Fe3+→Со2++Sі4+.

  7. Ion Cloud Modeling

    DTIC Science & Technology

    1977-11-11

    neutral collision time is discussed in Section 4.4. The chemical formulation for the barium thermite is based on the reaction of 2.5 moles of barium...per mole of cupric oxide according to the formula 2.5Ba + CuO - BaO + Cu + 1.5Ba. 23 In addition, 1.8% of the thermite weight was barium azide. 5 As a...constant value, tf . Generally at? 1 but if VD1 >> U 2 ,the value of atf * can be much less than 1 . In this case of rapid descent of the ion cloud, its

  8. Comparison of endoscopy and barium swallow with marshmallow in dysphagia.

    PubMed

    Somers, S; Stevenson, G W; Thompson, G

    1986-06-01

    Forty-four patients with dysphagia were examined both by endoscopy and by barium swallow with a marshmallow bolus. In these patients 36 stenoses were found: 34 by radiology and 30 by endoscopy. The radiologic criteria for stenosis included arrest of the marshmallow in a manner to support a column of barium and reproduction of the patient's symptoms at the time this occurred. Radiologic false negative findings were partly due to an inability by patients to swallow an adequate marshmallow bolus; endoscopic failures were associated with small endoscopes and mild stenoses.

  9. Standard Partial Molar Heat Capacities and Volumes of Barium and Cadmium Ions in Dimethylsulfoxide at 298.15 K

    NASA Astrophysics Data System (ADS)

    Novikov, A. N.; Doronin, Ya. I.; Rakhmanova, P. A.

    2018-07-01

    The heat capacities and volumes of dimethylsulfoxide (DMSO) solutions of barium and cadmium iodides at 298.15 K were measured by calorimetry and densimetry. The standard partial molar heat capacities \\bar C_{p,2}^° and volumes \\bar V2^° of BaI2 and CdI2 in DMSO were calculated. The standard heat capacities \\bar C_{p,i}^° and volumes \\bar {V}i^° of barium and cadmium ions in DMSO at 298.15 K were determined.

  10. Assessment of fluoride-induced changes on physicochemical and structural properties of bone and the impact of calcium on its control in rabbits.

    PubMed

    Gopalakrishnan, Subarayan Bothi; Viswanathan, Gopalan

    2012-03-01

    Bone deformities caused by the chronic intake of large quantities of fluoride and the beneficial effect of calcium on its control have been studied for many years, but only limited data are available on the quantitative effect of fluoride intake and the beneficial impact of calcium on fluoride-induced changes in bone at the molecular level. It is necessary to determine the degree of fluoride-induced changes in bone at different levels of fluoride intake to evaluate the optimum safe intake level of fluoride for maintaining bone health and quality. The ameliorative effect of calcium at different dose levels on minimizing fluoride-induced changes in bone is important to quantify the amount of calcium intake necessary for reducing fluoride toxicity. Thirty rabbits, 2 months old, were divided into five groups. Group I animals received 1 mg/l fluoride and 0.11% calcium diet; groups II and III received 10 mg/l fluoride and diet with 0.11% or 2.11% calcium, respectively; and groups IV and V received 150 mg/l fluoride and diet with 2.11% or 0.11% calcium, respectively. Analysis of bone density, ash content, fluoride, calcium, phosphorus, and Ca:P molar ratio levels after 6 months of treatment indicated that animals that received high fluoride with low-calcium diet showed significant detrimental changes in physicochemical properties of bone. Animals that received fluoride with high calcium intake showed notable amelioration of the impact of calcium on fluoride-induced changes in bone. The degree of fluoride-induced characteristic changes in structural properties such as crystalline size, crystallinity, and crystallographic "c"-axis length of bone apatite cells was also assessed by X-ray diffraction and Fourier transform infrared studies. X-ray images showed bone deformity changes such as transverse stress growth lines, soft tissue ossification, and calcification in different parts of bones as a result of high fluoride accumulation and the beneficial role of calcium intake on its control.

  11. Water fluoridation: a critical review of the physiological effects of ingested fluoride as a public health intervention.

    PubMed

    Peckham, Stephen; Awofeso, Niyi

    2014-01-01

    Fluorine is the world's 13th most abundant element and constitutes 0.08% of the Earth crust. It has the highest electronegativity of all elements. Fluoride is widely distributed in the environment, occurring in the air, soils, rocks, and water. Although fluoride is used industrially in a fluorine compound, the manufacture of ceramics, pesticides, aerosol propellants, refrigerants, glassware, and Teflon cookware, it is a generally unwanted byproduct of aluminium, fertilizer, and iron ore manufacture. The medicinal use of fluorides for the prevention of dental caries began in January 1945 when community water supplies in Grand Rapids, United States, were fluoridated to a level of 1 ppm as a dental caries prevention measure. However, water fluoridation remains a controversial public health measure. This paper reviews the human health effects of fluoride. The authors conclude that available evidence suggests that fluoride has a potential to cause major adverse human health problems, while having only a modest dental caries prevention effect. As part of efforts to reduce hazardous fluoride ingestion, the practice of artificial water fluoridation should be reconsidered globally, while industrial safety measures need to be tightened in order to reduce unethical discharge of fluoride compounds into the environment. Public health approaches for global dental caries reduction that do not involve systemic ingestion of fluoride are urgently needed.

  12. Effect of fluoride on growth and acid production by Streptococcus mutans in dental plaque.

    PubMed Central

    van der Hoeven, J S; Franken, H C

    1984-01-01

    The aim of this study was to measure the effect of fluoride on the production of organic acids by Streptococcus mutans in dental plaque. The effect was studied in a simplified model of dental plaque with gnotobiotic rats monoinfected with S. mutans Ny341. Adaptation of S. mutans to fluoride was induced by feeding one group of the rats on fluoride-containing diet and drinking water. No difference was found in the accumulation of S. mutans on the teeth between the fluoride-adapted and the control groups. However, there was a significant difference in the amount of lactic acid in metabolically resting plaque between the groups, lactic acid being lower in the fluoride-adapted plaque. At 5 min after a rinse containing 10% sucrose, a high level of lactic acid was found in plaque from animals not exposed to fluoride. Rinses containing 4 or 20 mM fluoride before the sucrose rinse significantly inhibited the lactic acid production in the control group. In the plaque from rats on fluoridated diet and drinking water the sucrose-induced production of lactic acid was not inhibited by a 4 mM fluoride rinse. Moreover, the production of lactic acid in the fluoride-adapted plaque was prolonged. The results indicate that due to fluoride adaptation the inhibition of acid production is unlikely to be important for the caries-preventive action of fluoride. PMID:6746094

  13. Water Fluoridation: A Critical Review of the Physiological Effects of Ingested Fluoride as a Public Health Intervention

    PubMed Central

    2014-01-01

    Fluorine is the world's 13th most abundant element and constitutes 0.08% of the Earth crust. It has the highest electronegativity of all elements. Fluoride is widely distributed in the environment, occurring in the air, soils, rocks, and water. Although fluoride is used industrially in a fluorine compound, the manufacture of ceramics, pesticides, aerosol propellants, refrigerants, glassware, and Teflon cookware, it is a generally unwanted byproduct of aluminium, fertilizer, and iron ore manufacture. The medicinal use of fluorides for the prevention of dental caries began in January 1945 when community water supplies in Grand Rapids, United States, were fluoridated to a level of 1 ppm as a dental caries prevention measure. However, water fluoridation remains a controversial public health measure. This paper reviews the human health effects of fluoride. The authors conclude that available evidence suggests that fluoride has a potential to cause major adverse human health problems, while having only a modest dental caries prevention effect. As part of efforts to reduce hazardous fluoride ingestion, the practice of artificial water fluoridation should be reconsidered globally, while industrial safety measures need to be tightened in order to reduce unethical discharge of fluoride compounds into the environment. Public health approaches for global dental caries reduction that do not involve systemic ingestion of fluoride are urgently needed. PMID:24719570

  14. PRODUCTION OF PLUTONIUM FLUORIDE FROM BISMUTH PHOSPHATE PRECIPITATE CONTAINING PLUTONIUM VALUES

    DOEpatents

    Brown, H.S.; Bohlmann, E.G.

    1961-05-01

    A process is given for separating plutonium from fission products present on a bismuth phosphate carrier. The dried carrier is first treated with hydrogen fluoride at between 500 and 600 deg C whereby some fission product fluorides volatilize away from plutonium tetrafluoride, and nonvolatile fission product fluorides are formed then with anhydrous fluorine at between 400 and 500 deg C. Bismuth and plutonium distill in the form of volatile fluorides away from the nonvolatile fission product fluorides. The bismuth and plutonium fluorides are condensed at below 290 deg C.

  15. Chemico-therapeutic approach to prevention of dental caries. [using stannous fluoride gel

    NASA Technical Reports Server (NTRS)

    Shannon, I. L.

    1975-01-01

    The program of chemical preventive dentistry is based primarily upon the development of a procedure for stabilizing stannous fluoride in solution by forcing it into glycerin. New topical fluoride treatment concentrates, fluoride containing gels and prophylaxis pastes, as well as a completely stable stannous fluoride dentifrice are made possible by the development of a rather complicated heat application method to force stannous fluoride into solution in glycerin. That the stannous fluoride is clinically effective in such a preparation is demonstrated briefly on orthodontic patients.

  16. Oesophageal narrowing on barium oesophagram is more common in adult patients with eosinophilic oesophagitis than PPI-responsive oesophageal eosinophilia.

    PubMed

    Podboy, A; Katzka, D A; Enders, F; Larson, J J; Geno, D; Kryzer, L; Alexander, J

    2016-06-01

    To date there have been no clear features that aid in differentiating patients with eosinophilic oesophagitis (EoE) from PPI-responsive oesophageal eosinophilia (PPI-REE). However, barium swallow roentgenography is a more sensitive and specific measure to detect subtle fibrostenotic remodeling changes present in EoE. We aim to characterise any clinical, endoscopic, histiological or barium roentgenographic differences between EoE and PPI-REE. To characterise any clinical, endoscopic, histiological or barium roentgenographic differences between EoE and PPI-REE. We performed a retrospective cohort analysis on data collected from a tertiary referral centre population from 2010 to 2015. Data from 66 patients with EoE and 28 patients with PPI-REE were analysed. Cases were adults who met consensus guidelines for EOE, and had a barium swallow study within 6 months of the index endoscopy. Clinical, endoscopic, histiological and barium swallow findings were collected. Patients with EoE reported similar characteristics as PPI-REE patients, except EoE patients were younger (35.6 vs. 46.6 years; P = 0.011), had earlier symptom onset (29.0 vs. 38.0 years; P = 0.026), and smaller oesophageal diameters on barium swallow (19.5 mm vs. 20; P = 0.042). Patients with EoE were more likely to have distal strictures (EoE 77% vs. 25%; P = 0.02) and, importantly, a greater likelihood of small calibre oesophagus (51.5% vs. 17.9%; P = 0.002). Moreover, EoE patients had a higher probability of developing small calibre oesophagus after 20 years of symptoms (72.3% vs. 30.2%; P = 0.074) compared to PPI-REE patients. When compared with eosinophilic oesophagitis, PPI-REE patients demonstrate findings that suggest PPI-responsive oesophageal eosinophilia to be a later onset, less aggressive form of oesophageal stricturing disease than eosinophilic oesophagitis. © 2016 John Wiley & Sons Ltd.

  17. Effects of fluoridated milk on root dentin remineralization.

    PubMed

    Arnold, Wolfgang H; Heidt, Bastian A; Kuntz, Sebastian; Naumova, Ella A

    2014-01-01

    The prevalence of root caries is increasing with greater life expectancy and number of retained teeth. Therefore, new preventive strategies should be developed to reduce the prevalence of root caries. The aim of this study was to investigate the effects of fluoridated milk on the remineralization of root dentin and to compare these effects to those of sodium fluoride (NaF) application without milk. Thirty extracted human molars were divided into 6 groups, and the root cementum was removed from each tooth. The dentin surface was demineralized and then incubated with one of the following six solutions: Sodium chloride NaCl, artificial saliva, milk, milk+2.5 ppm fluoride, milk+10 ppm fluoride and artificial saliva+10 ppm fluoride. Serial sections were cut through the lesions and investigated with polarized light microscopy and quantitative morphometry, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). The data were statistically evaluated using a one-way ANOVA for multiple comparisons. The depth of the lesion decreased with increasing fluoride concentration and was the smallest after incubation with artificial saliva+10 ppm fluoride. SEM analysis revealed a clearly demarcated superficial remineralized zone after incubation with milk+2.5 ppm fluoride, milk+10 ppm fluoride and artificial saliva+10 ppm fluoride. Ca content in this zone increased with increasing fluoride content and was highest after artificial saliva+10 ppm fluoride incubation. In the artificial saliva+10 ppm fluoride group, an additional crystalline layer was present on top of the lesion that contained elevated levels of F and Ca. Incubation of root dentin with fluoridated milk showed a clear effect on root dentin remineralization, and incubation with NaF dissolved in artificial saliva demonstrated a stronger effect.

  18. Evaluation of salivary fluoride retention from a new high fluoride mouthrinse.

    PubMed

    Mason, Stephen C; Shirodaria, Soha; Sufi, Farzana; Rees, Gareth D; Birkhed, Dowen

    2010-11-01

    To evaluate salivary fluoride retention from a new high fluoride daily use mouthrinse over a 120 min period. Sixteen subjects completed a randomised single-blind, four-treatment cross-over trial. Sensodyne® Pronamel® mouthrinse (A) contained 450 ppm fluoride; reference products were Colgate® Fluorigard® (B), Listerine® Total Care (C) and Listerine Softmint Sensation (D) containing 225, 100 and 0 ppm fluoride respectively. Salivary fluoride retention was monitored ex vivo after a single supervised use of test product (10 mL, 60 s). Samples were collected at 0, 1, 3, 5, 15, 30, 60 and 120 min post-rinse, generating fluoride clearance curves from which the area under the curve (AUC) was calculated. Differences in salivary fluoride concentrations for each product were analysed using ANCOVA at each time point using a 5% significance level, as well as lnAUC for the periods 0-120, 0-1, 1-15, 15-60 and 60-120 min. Pairwise comparisons between all treatment groups were performed. Salivary fluoride levels for A-C peaked immediately following use. Fluoride levels were statistically significantly higher for A versus B-D (p≤ 0.004), linear dose responses were apparent. AUC(0-120) was statistically significantly greater for A than for B (p = 0.035), C (p< 0.0001) and D (p< 0.0001). Post-hoc comparisons of lnAUC for the remaining time domains showed fluoride retention from A was statistically significantly greater versus B-D (p< 0.0001). Single-use treatment with the new mouthrinse containing 450 ppm fluoride resulted in statistically significantly higher salivary fluoride levels throughout the 120 min test period. Total fluoride retention (AUC(0-120)) was also statistically significantly greater versus comparator rinse treatments. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Fluoride Increase in Saliva and Dental Biofilm due to a Meal Prepared with Fluoridated Water or Salt: A Crossover Clinical Study.

    PubMed

    Lima, Carolina V; Tenuta, Livia M A; Cury, Jaime A

    2018-06-07

    Knowledge about fluoride delivery to oral fluids from foods cooked with fluoridated water and salt is scarce, and no study has evaluated fluoride concentrations in saliva or biofilm during meal consumption. In this randomized double-blind crossover study, 12 volunteers ingested meals (rice, beans, meat, and legumes) prepared with nonfluoridated water and salt (control group), fluoridated water (0.70 mg F/L; water group), and fluoridated salt (183.7 mg F/kg; salt group). Whole saliva was collected before meal ingestion, during mastication, and up to 2 h after meal ingestion. Dental biofilm was collected before and immediately after meal ingestion. Fluoride concentrations in saliva and dental biofilm were determined by an ion-specific electrode. The mean (±standard deviation; n = 4) fluoride concentrations in meals prepared for the control, water, and salt groups were 0.039 ± 0.01, 0.43 ± 0.04, and 1.71 ± 0.32 μg F/g, respectively. The three groups had significantly different fluoride concentrations in saliva collected during mastication (p < 0.0001) and after meal ingestion (p < 0.04; salt > water > control). The fluoride concentration in saliva returned to baseline 30 min after meal ingestion in the water group but remained high for up to 2 h in the salt group (p = 0.002). The fluoride concentration in biofilm fluid differed only between the salt and control groups (p = 0.008). The mastication of foods cooked with fluoridated water and salt increases fluoride concentrations in oral fluids and may contribute to the local effect of these community-based fluoride interventions on caries control. © 2018 S. Karger AG, Basel.

  20. Salt fluoridation and oral health.

    PubMed

    Marthaler, Thomas M

    2013-11-01

    The aim of this paper is to make known the potential of fluoridated salt in community oral health programs, particularly in South Eastern Europe. Since 1922, the addition of iodine to salt has been successful in Switzerland. Goiter is virtually extinct. By 1945, the caries-protective effect of fluorides was well established. Based on the success of water fluoridation, a gynecologist started adding of fluoride to salt. The sale of fluoridated salt began in 1956 in the Swiss Canton of Zurich, and several other cantons followed suit. Studies initiated in the early seventies showed that fluoride, when added to salt, inhibits dental caries. The addition of fluoride to salt for human consumption was officially authorized in 1980-82. In Switzerland 85% of domestic salt consumed is fluoridated and 67% in Germany. Salt fluoridation schemes are reaching more than one hundred million in Mexico, Colombia, Peru and Cuba. The cost of salt fluoridation is very low, within 0.02 and 0.05 € per year and capita. Children and adults of the low socio-economic strata tend to have substantially more untreated caries than higher strata. Salt fluoridation is by far the cheapest method for improving oral health. Salt fluoridation has cariostatic potential like water fluoridation (caries reductions up to 50%). In Europe, meaningful percentages of users have been attained only in Germany (67%) and Switzerland (85%). In Latin America, there are more than 100 million users, and several countries have arrived at coverage of 90 to 99%. Salt fluoridation is by far the cheapest method of caries prevention, and billions of people throughout the world could benefit from this method. Copyright © 2013 by Academy of Sciences and Arts of Bosnia and Herzegovina.

  1. Salt fluoridation--an alternative in automatic prevention of dental caries.

    PubMed

    Marthaler, T M; Petersen, P E

    2005-12-01

    Despite great improvements in terms of reduced prevalence and amount of dental caries in populations worldwide, problems still persist particularly among the underprivileged groups of both developed and developing countries. Research and practical experience gained in several countries have demonstrated however, that dental caries can be prevented effectively through establishment of fluoride programmes. Water fluoridation, salt fluoridation, milk fluoridation and use of affordable fluoridated toothpastes play the major roles in public health. The present paper outlines the relevance and some practical aspects in relation to implementation of salt fluoridation programmes. The World Health Organisation Oral Health Programme provides technical assistance to countries in the process of planning, implementing and evaluating salt fluoridation projects.

  2. Innovations in biomedical nanoengineering: nanowell array biosensor.

    PubMed

    Seo, YoungTae; Jeong, Sunil; Lee, JuKyung; Choi, Hak Soo; Kim, Jonghan; Lee, HeaYeon

    2018-01-01

    Nanostructured biosensors have pioneered biomedical engineering by providing highly sensitive analyses of biomolecules. The nanowell array (NWA)-based biosensing platform is particularly innovative, where the small size of NWs within the array permits extremely profound sensing of a small quantity of biomolecules. Undoubtedly, the NWA geometry of a gently-sloped vertical wall is critical for selective docking of specific proteins without capillary resistances, and nanoprocessing has contributed to the fabrication of NWA electrodes on gold substrate such as molding process, e-beam lithography, and krypton-fluoride (KrF) stepper semiconductor method. The Lee group at the Mara Nanotech has established this NW-based biosensing technology during the past two decades by engineering highly sensitive electrochemical sensors and providing a broad range of detection methods from large molecules (e.g., cells or proteins) to small molecules (e.g., DNA and RNA). Nanosized gold dots in the NWA enhance the detection of electrochemical biosensing to the range of zeptomoles in precision against the complementary target DNA molecules. In this review, we discuss recent innovations in biomedical nanoengineering with a specific focus on novel NWA-based biosensors. We also describe our continuous efforts in achieving a label-free detection without non-specific binding while maintaining the activity and stability of immobilized biomolecules. This research can lay the foundation of a new platform for biomedical nanoengineering systems.

  3. Design and fabrication of a 40-MHz annular array transducer

    PubMed Central

    Ketterling, Jeffrey A.; Lizzi, Frederic L.; Aristizábal, Orlando; Turnbull, Daniel H.

    2006-01-01

    This paper investigates the feasibility of fabricating a 5-ring, focused annular array transducer operating at 40 MHz. The active piezoelectric material of the transducer was a 9-μm thick polyvinylidene fluoride (PVDF) film. One side of the PVDF was metallized with gold and forms the ground plane of the transducer. The array pattern of the transducer and electrical traces to each annulus were formed on a copper-clad polyimide film. The PVDF and polyimide were bonded with a thin layer of epoxy, pressed into a spherically curved shape, and then back filled with epoxy. A 5-ring transducer with equal area elements and 100 μm kerfs between annuli was fabricated and tested. The transducer had a total aperture of 6 mm and a geometric focus of 12 mm. The pulse/echo response from a quartz plate located at the geometric focus, two-way insertion loss (IL), complex impedance, electrical cross-talk, and lateral beamwidth were all measured for each annulus. The complex impedance data from each element were used to perform electrical matching and the measurements were repeated. After impedance matching, fc ≈ 36 MHz and BWs ranged from 31 to 39%. The ILs for the matched annuli ranged from −28 to −38 dB. PMID:16060516

  4. Innovations in biomedical nanoengineering: nanowell array biosensor

    NASA Astrophysics Data System (ADS)

    Seo, YoungTae; Jeong, Sunil; Lee, JuKyung; Choi, Hak Soo; Kim, Jonghan; Lee, HeaYeon

    2018-04-01

    Nanostructured biosensors have pioneered biomedical engineering by providing highly sensitive analyses of biomolecules. The nanowell array (NWA)-based biosensing platform is particularly innovative, where the small size of NWs within the array permits extremely profound sensing of a small quantity of biomolecules. Undoubtedly, the NWA geometry of a gently-sloped vertical wall is critical for selective docking of specific proteins without capillary resistances, and nanoprocessing has contributed to the fabrication of NWA electrodes on gold substrate such as molding process, e-beam lithography, and krypton-fluoride (KrF) stepper semiconductor method. The Lee group at the Mara Nanotech has established this NW-based biosensing technology during the past two decades by engineering highly sensitive electrochemical sensors and providing a broad range of detection methods from large molecules (e.g., cells or proteins) to small molecules (e.g., DNA and RNA). Nanosized gold dots in the NWA enhance the detection of electrochemical biosensing to the range of zeptomoles in precision against the complementary target DNA molecules. In this review, we discuss recent innovations in biomedical nanoengineering with a specific focus on novel NWA-based biosensors. We also describe our continuous efforts in achieving a label-free detection without non-specific binding while maintaining the activity and stability of immobilized biomolecules. This research can lay the foundation of a new platform for biomedical nanoengineering systems.

  5. Upper Gastrointestinal (GI) Series

    MedlinePlus

    ... abdomen or ask you to change position several times to evenly coat your upper GI tract with the barium. If you are having a double-contrast study, you will swallow gas-forming crystals that mix with the barium coating your stomach. ...

  6. Observation of a barium xenon exciplex within a large argon cluster.

    PubMed

    Briant, M; Gaveau, M-A; Mestdagh, J-M

    2010-07-21

    Spectroscopic measurements provide fluorescence and excitation spectra of a single barium atom codeposited with xenon atoms on argon clusters of average size approximately 2000. The spectra are studied as a function of the number of xenon atoms per cluster. The excitation spectrum with approximately 10 xenon atoms per cluster is qualitatively similar to that observed when no xenon atom is present on the cluster. It consists of two bands located on each side of the 6s6p (1)P-6s(2) (1)S resonance line of the free barium. In contrast, the fluorescence spectrum differs qualitatively since a barium-xenon exciplex is observed, which has no counterpart in xenon free clusters. In particular an emission is observed, which is redshifted by 729 cm(-1) with respect to the Ba(6s6p (1)P-6s(2) (1)S) resonance line.

  7. Atomic emission spectrometer/spectrograph for the determination of barium in microamounts of diatom ash

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bankston, D.C.; Fisher, N.S.

    1977-06-01

    The development and routine application of a method for the determination of trace levels of barium in microsamples (5-10 mg) of diatom ash is described Acid-dissolved lithium metaborate fusion melts of ash samples are analyzed using a spectrometer/spectrograph equipped with a dc argon plasma jet excitation source and an echelle diffraction grating. Sample, standard, and blank solutions are buffered by lithium contributed by the flux, to a degree sufficient to reduce matrix effects to acceptable levels. Previous barium determinations by other analytical techniques, on seven interlaboratory reference materials, have been used to establish the accuracy of our results. The averagemore » relative standard deviation for the instrumental analyses was 0.07. Using recommended instrument settings, moreover, the lowest concentration of barium visible in synthetic standard solutions lies just below 2 ..mu..g/L, which is equivalent to 2 ..mu..g/g in the ash.« less

  8. Prompt ionization in the CRIT II barium releases. [Critical Ionization Tests

    NASA Technical Reports Server (NTRS)

    Torbert, R. B.; Kletzing, C. A.; Liou, K.; Rau, D.

    1992-01-01

    Observations of electron and ion distributions inside a fast neutral barium jet in the ionosphere show significant fluxes within 4 km of release, presumably related to beam plasma instability processes involved in the Critical Ionization Velocity (CIV) effect. Electron fluxes exceeding 5 x 10 exp 12/sq cm-str-sec-keV were responsible for ionizing both the streaming barium and ambient oxygen. Resulting ion fluxes seem to be consistent with 1-2 percent ionization of the fast barium, as reported by optical observations, although the extended spatial distribution of the optically observed ions is difficult to reconcile with the in situ observations. When the perpendicular velocity of the neutrals falls below critical values, these processes shut off. Although these observations resemble the earlier Porcupine experimental results (Haerendel, 1982), theoretical understanding of the differences between these data and that of earlier negative experiments is still lacking.

  9. Phase transition studies in barium and strontium titanates at microwave frequencies

    NASA Technical Reports Server (NTRS)

    Dahiya, Jai N.

    1993-01-01

    The objectives were the following: to understand the phase transformations in barium and strontium titanates as the crystals go from one temperature to the other; and to study the dielectric behavior of barium and strontium titanate crystals at a microwave frequency of 9.12 GHz and as a function of temperature. Phase transition studies in barium and strontium titanate are conducted using a cylindrical microwave resonant cavity as a probe. The cavity technique is quite successful in establishing the phase changes in these crystals. It appears that dipole relaxation plays an important role in the behavior of the dielectric response of the medium loading the cavity as phase change takes place within the sample. The method of a loaded resonant microwave cavity as applied in this work has proven to be sensitive enough to monitor small phase changes of the cavity medium.

  10. SAD phasing with in-house cu Ka radiation using barium as anomalous scatterer.

    PubMed

    Dhanasekaran, V; Velmurugan, D

    2011-12-01

    Phasing of lysozyme crystals using co-crystallized barium ions was performed using single-wavelength anomalous diffraction (SAD) method using Cu Ka radiation with in-house source of data collection. As the ion binding sites vary with respect to the pH of the buffer during crystallization, the highly isomorphic forms of lysozyme crystals grown at acidic and alkaline pH were used for the study. Intrinsic sulphur anomalous signal was also utilized with anomalous signal from lower occupancy ions for phasing. The study showed that to solve the structure by SAD technique, 2.8-fold data redundancy was sufficient when barium was used as an anomalous marker in the in-house copper X-ray radiation source for data collection. Therefore, co-crystallization of proteins with barium containing salt can be a powerful tool for structure determination using lab source.

  11. BaTiO3-based piezoelectrics: Fundamentals, current status, and perspectives

    NASA Astrophysics Data System (ADS)

    Acosta, M.; Novak, N.; Rojas, V.; Patel, S.; Vaish, R.; Koruza, J.; Rossetti, G. A.; Rödel, J.

    2017-12-01

    We present a critical review that encompasses the fundamentals and state-of-the-art knowledge of barium titanate-based piezoelectrics. First, the essential crystallography, thermodynamic relations, and concepts necessary to understand piezoelectricity and ferroelectricity in barium titanate are discussed. Strategies to optimize piezoelectric properties through microstructure control and chemical modification are also introduced. Thereafter, we systematically review the synthesis, microstructure, and phase diagrams of barium titanate-based piezoelectrics and provide a detailed compilation of their functional and mechanical properties. The most salient materials treated include the (Ba,Ca)(Zr,Ti)O3, (Ba,Ca)(Sn,Ti)O3, and (Ba,Ca)(Hf,Ti)O3 solid solution systems. The technological relevance of barium titanate-based piezoelectrics is also discussed and some potential market indicators are outlined. Finally, perspectives on productive lines of future research and promising areas for the applications of these materials are presented.

  12. Multiphoton laser ionization for energy conversion in barium vapor

    NASA Astrophysics Data System (ADS)

    Makdisi, Y.; Kokaj, J.; Afrousheh, K.; Mathew, J.; Nair, R.; Pichler, G.

    2013-03-01

    We have studied the ion detection of barium atoms in special heated ovens with a tungsten rod in the middle of the stainless steel tube. The tungsten rod was heated indirectly by the oven body heaters. A bias voltage between the cell body and the tungsten rod of 9 V was used to collect electrons, after the barium ions had been created. However, we could collect the electrons even without the bias voltage, although with ten times less efficiency. We studied the conditions for the successful bias-less thermionic signal detection using excimer/dye laser two-photon excitation of Rydberg states below and above the first ionization limit (two-photon wavelength at 475.79 nm). We employed a hot-pipe oven and heat-pipe oven (with inserted mesh) in order to generate different barium vapor distributions inside the oven. The thermionic signal increased by a factor of two under heat-pipe oven conditions.

  13. Plasma irregularities caused by cycloid bunching of the CRRES G-2 barium release

    NASA Technical Reports Server (NTRS)

    Bernhardt, P. A.; Huba, J. D.; Pongratz, M. B.; Simons, D. J.; Wolcott, J. H.

    1993-01-01

    The Combined Release and Radiation Effects Satellite (CRRES) spacecraft carried a number of barium thermite canisters for release into the upper atmosphere. The barium release labeled G-2 showed evidence of curved irregularities not aligned with the ambient magnetic field B. The newly discovered curved structures can be explained by a process called cycloid bunching. Cycloid bunching occurs when plasma is created by photoionization of a neutral cloud injected at high velocity perpendicular to B. If the injection velocity is much larger than the expansion speed of the cloud, the ion trail will form a cycloid that has irregularities spaced by the product of the perpendicular injection speed and the ion gyroperiod, Images of the solar-illuminated barium ions are compared with the results of a three-dimensional kinetic simulation. Cycloid bunching is shown to be responsible for the rapid generation of both curved and field-aligned irregularities in the CRRES G-2 experiment.

  14. The Relationship Between Observations and Measures of Oral and Pharyngeal Residue from Videofluorography and Scintigraphy

    PubMed Central

    Logemann, Jeri A.; Williams, Rohan B.; Rademaker, Alfred; Pauloski, Barbara Roa; Lazarus, Cathy L.; Cook, Ian

    2006-01-01

    We examined measures of oral and pharyngeal residues from scintigraphic studies and estimates/observations from videofluorographic (modified barium swallow) studies taken on the same day but not concurrently in 16 dysphagic patients of varying etiologies presenting with oral and/or pharyngeal dysphagia. Oral and pharyngeal residuals following the swallow were quantified scintigraphically and were then compared with measures of residuals obtained from the modified barium swallow. Estimates of oral and pharyngeal residues from the modified barium swallows were generated by a trained observer who was blinded to the scintigraphic data. Positive and significant Spearman correlations between oral and pharyngeal residue measures from scintigraphy and observations of oral and pharyngeal residues from modified barium swallows were found. This supports the validity of observations of oral and pharyngeal residues in clinical studies. Limitations of these observations are discussed. PMID:16362511

  15. Fluoride’s Effects on the Formation of Teeth and Bones, and the Influence of Genetics

    PubMed Central

    Everett, E.T.

    2011-01-01

    Fluorides are present in the environment. Excessive systemic exposure to fluorides can lead to disturbances of bone homeostasis (skeletal fluorosis) and enamel development (dental/enamel fluorosis). The severity of dental fluorosis is also dependent upon fluoride dose and the timing and duration of fluoride exposure. Fluoride’s actions on bone cells predominate as anabolic effects both in vitro and in vivo. More recently, fluoride has been shown to induce osteoclastogenesis in mice. Fluorides appear to mediate their actions through the MAPK signaling pathway and can lead to changes in gene expression, cell stress, and cell death. Different strains of inbred mice demonstrate differential physiological responses to ingested fluoride. Genetic studies in mice are capable of identifying and characterizing fluoride-responsive genetic variations. Ultimately, this can lead to the identification of at-risk human populations who are susceptible to the unwanted or potentially adverse effects of fluoride action and to the elucidation of fundamental mechanisms by which fluoride affects biomineralization. PMID:20929720

  16. Is the fluoride intake by diet and toothpaste in children living in tropical semi-arid city safe?

    PubMed

    Oliveira, Priscila Ferreira Torres de; Cury, Jaime Aparecido; Lima, Carolina Veloso; Vale, Glauber Campos; Lima, Marina de Deus Moura de; Moura, Lúcia de Fátima Almeida de Deus; Moura, Marcoeli Silva de

    2018-01-01

    Data about total fluoride intake in children living in a tropical semi-arid climate city is scarce, thus we conducted this study. Fifty-eight children aged two to five years, living in a Brazilian tropical city with optimally fluoridated water were selected. Dietary samples were collected using the duplicate diet method on two non-consecutive days in the children's home toothpaste was determined by subtracting the amount of fluoride recovered after brushing from the amount placed on the toothbrush. The mean total dose (SD) of fluoride intake was 0.043(0.016) mg F·kg-1·d-1, with the major (60.6%) contribution from water. The factors associated with the ingestion of fluoride from toothpaste were fluoride concentration of the toothpaste (p = 0.03) and the use of kids toothpaste (p = 0.02). The findings suggest that children have a low fluoride intake, measured by at-home meals and use of fluoride toothpaste; drinking water is the main source of fluoride ingestion.

  17. Sodium trimetaphosphate enhances the effect of 250 p.p.m. fluoride toothpaste against enamel demineralization in vitro.

    PubMed

    Missel, Emilene M C; Cunha, Robson F; Vieira, Ana E M; Cruz, Nathália V S; Castilho, Flavia C N; Delbem, Alberto C B

    2016-08-01

    This in vitro study investigated the effect of sodium trimetaphosphate (TMP), added to toothpaste containing 250 p.p.m. fluoride, on enamel demineralization. Bovine enamel blocks (n = 96) were subjected to five pH cycles over a 7-d period and treatment with suspensions of toothpastes containing 0, 250, 500, and 1,100 p.p.m. fluoride (as sodium fluoride), as well as with 250 p.p.m. fluoride containing TMP at 0.25, 0.5, 1.0, and 3.0%. Treatment with toothpaste suspensions was performed under agitation twice a day, for 1 min. Surface and cross-sectional hardness, and fluoride firmly bound to enamel, were quantified. Data were subjected to one-way anova, followed by Tukey's test. Low-fluoride toothpastes containing TMP at 0.25-1.0% resulted in enamel mineral loss similar to that seen for the toothpaste containing 1,100 p.p.m. fluoride. Also, the addition of TMP to the toothpaste containing 250 p.p.m. fluoride promoted enamel fluoride concentrations similar to those obtained for the 500 p.p.m. fluoride group. The toothpaste containing 250 p.p.m. fluoride and 0.25% TMP led to the lowest mineral loss among all groups. It was concluded that the addition of as little as 0.25% TMP to a toothpaste containing 250 p.p.m. fluoride can reduce enamel demineralization to levels similar to those seen for a conventional toothpaste containing 1,100 p.p.m. fluoride, in vitro. © 2016 Eur J Oral Sci.

  18. Fluoride concentration in dentine as a biomarker of fluoride intake in European roe deer (Capreolus capreolus) - an electron-microprobe study.

    PubMed

    Richter, Heiko; Kierdorf, Uwe; Richards, Alan; Melcher, Frank; Kierdorf, Horst

    2011-08-01

    Fluoride concentration in dentine has been recommended as the best marker for the level of chronic fluoride intake and the most suitable indicator of an individual's total body burden of fluoride. We analysed fluoride concentrations in the dentine of cheek teeth of European roe deer from fluoride-polluted habitats to retrospectively assess the level of fluoride uptake into the tissue. Thereby, we tested the hypothesis of the existence of mechanisms that limit fluoride intake of individuals and fluoride exposure of forming dental hard tissues during the late foetal and early postnatal periods in the species. Using electron-microprobe analysis, fluoride profiles were obtained on sectioned P(4)s, M(1)s, and M(3)s from individuals exhibiting pronounced dental fluorosis. Fluoride concentrations were compared between early formed (peripheral) and late-formed (juxtapulpal) dentine both within single teeth and amongst the three different teeth studied. Peripheral dentine of the M(1), which is formed during the late foetal and early postnatal periods, exhibited markedly lower fluoride concentrations than juxtapulpal dentine of the same tooth and both, peripheral and juxtapulpal dentine of P(4) and M(3) that are formed post-weaning. Our study provides strong support for the hypothesis that in the European roe deer the prenatal and early postnatal (pre-weaning) stages of dental development are (largely) protected against exposure to excess fluoride. This is attributed to the operation of certain protective mechanisms during these periods. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Critical factors determining fluoride concentration in tea leaves produced from Anhui province, China.

    PubMed

    Cai, Huimei; Zhu, Xiaohui; Peng, Chuanyi; Xu, Wei; Li, Daxiang; Wang, Yijun; Fang, Shihui; Li, Yeyun; Hu, Shaode; Wan, Xiaochun

    2016-09-01

    This study investigated the fluoride present in tea plants (Camellia sinensis (L.) O. Kuntze) and its relationship to soils, varieties, seasons and tea leaf maturity. The study also explored how different manufacturing processes affect the leaching of fluoride into tea beverages. The fluoride concentration in the tea leaves was significantly correlate to the concentration of water-soluble fluoride in the soil. Different tea varieties accumulated different levels of fluoride, with varieties, Anji baicha having the highest and Nongkang zao having the lowest fluoride concentration. In eight different varieties of tea plant harvested over three tea seasons, fluoride concentration were highest in the summer and lowest in the spring in china. The fluoride concentration in tea leaves was directly related to the maturity of the tea leaves at harvest. Importantly, the tea manufacturing process did not introduced fluoride contamination. The leaching of fluoride was 6.8% and 14.1% higher in black and white tea, respectively, than in fresh tea leaves. The manufacturing step most affecting the leaching of fluoride into tea beverage was withering used in white, black and oolong tea rather than rolling or fermentation. The exposure and associated health risks for fluoride concentration in infusions of 115 commercially available teas from Chinese tea markets was determined. The fluoride concentration ranged from 5.0 to 306.0mgkg(-1), with an average of 81.7mgkg(-1). The hazard quotient (HQ) of these teas indicated that there was no risk of fluorosis from drinking tea, based on statistical analysis by Monte Carlo simulation. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Fluoride exposure and indicators of thyroid functioning in the Canadian population: implications for community water fluoridation

    PubMed Central

    Barberio, Amanda M; Hosein, F Shaun; Quiñonez, Carlos; McLaren, Lindsay

    2017-01-01

    Background There are concerns that altered thyroid functioning could be the result of ingesting too much fluoride. Community water fluoridation (CWF) is an important source of fluoride exposure. Our objectives were to examine the association between fluoride exposure and (1) diagnosis of a thyroid condition and (2) indicators of thyroid functioning among a national population-based sample of Canadians. Methods We analysed data from Cycles 2 and 3 of the Canadian Health Measures Survey (CHMS). Logistic regression was used to assess associations between fluoride from urine and tap water samples and the diagnosis of a thyroid condition. Multinomial logistic regression was used to examine the relationship between fluoride exposure and thyroid-stimulating hormone (TSH) level (low/normal/high). Other available variables permitted additional exploratory analyses among the subset of participants for whom we could discern some fluoride exposure from drinking water and/or dental products. Results There was no evidence of a relationship between fluoride exposure (from urine and tap water) and the diagnosis of a thyroid condition. There was no statistically significant association between fluoride exposure and abnormal (low or high) TSH levels relative to normal TSH levels. Rerunning the models with the sample constrained to the subset of participants for whom we could discern some source(s) of fluoride exposure from drinking water and/or dental products revealed no significant associations. Conclusion These analyses suggest that, at the population level, fluoride exposure is not associated with impaired thyroid functioning in a time and place where multiple sources of fluoride exposure, including CWF, exist. PMID:28839078

  1. [Effect of fluoride on human hypothalamus-hypophysis-testis axis hormones].

    PubMed

    Hao, Pengfei; Ma, Xiaoying; Cheng, Xuemin; Ba, Yue; Zhu, Jingyuan; Cui, Liuxin

    2010-01-01

    To study of endocrine disturbing effect of fluoride on human hypothalamus-hypophysis-testis axis hormones. Sunying County, Kaifeng City was selected as polluted district which the fluoride in drinking water was 3.89 mg/L, and Shenlilou county was selected as control district which the fluoride was less than 1.0 mg/L. 150 individual lived there more than 5 years were srlected randomly. And investigated by medical examination, then blood and urine sample were collected, and the serum level of gonadotropin-releasing hormone (GnRH), luteinizing hormone (LH), testosterone (T) and estradiol (E2) were measured by RIA method, and the urine level of fluoride were measured. Other than that, the concentration of fluoride in the water, food, soil and air were detected by the standard methods. The concentrations of fluoride in the water, food and soil of the fluoride polluted district were significantly higher than those of control district (P < 0.05), and the concentration fluoride in the air of two district were not found. There was no significant difference of serum level of GnRH between fluoride polluted district and control district (P > 0.05). The serum level of LH in men of fluoride polluted district was significantly higher than that of control group (P < 0.05), and the serum level of T in men of fluoride polluted district was significantly less than that of control group (P < 0.05). There was no significant difference of serum level of LH between fluoride polluted district and control district (P > 0.05), and the serum level of T in women of fluoride polluted district was significantly higher than that of control group (P < 0.05). There was no significant difference of serum level of E2 between fluoride polluted district and control district (P > 0.05). Fluoride could effect hormone levels of each layer of the hypothalamus-hypophysis-testis axis, and show the reproductive endocrine disturbing effects. The reproductive endocrine disturbing effects of male maybe more severe than those of female.

  2. 49 CFR 173.163 - Hydrogen fluoride.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Hydrogen fluoride. 173.163 Section 173.163... Hydrogen fluoride. (a) Hydrogen fluoride (hydrofluoric acid, anhydrous) must be packaged as follows: (1) In... filling ratio of 0.84. (b) A cylinder removed from hydrogen fluoride service must be condemned in...

  3. 49 CFR 173.163 - Hydrogen fluoride.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Hydrogen fluoride. 173.163 Section 173.163... Hydrogen fluoride. (a) Hydrogen fluoride (hydrofluoric acid, anhydrous) must be packaged as follows: (1) In... filling ratio of 0.84. (b) A cylinder removed from hydrogen fluoride service must be condemned in...

  4. 49 CFR 173.163 - Hydrogen fluoride.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Hydrogen fluoride. 173.163 Section 173.163... Hydrogen fluoride. (a) Hydrogen fluoride (hydrofluoric acid, anhydrous) must be packaged as follows: (1) In... filling ratio of 0.84. (b) A cylinder removed from hydrogen fluoride service must be condemned in...

  5. FLUORIDATION CHEMISTRY: EQUILIBRIA AND KINETICS OF FLUORIDE AND FLUORO-COMPLEXES

    EPA Science Inventory

    The most common fluoridating agents used by major American waterworks are hexafluorosilicic acid (H2SiF6) and sodium hexxafluorosilicate (Na2SiF6). According to the 1992 Water Fluoridation Census where 10,002 utilities responded affirmatively to fluoridating their water, 59
    % ...

  6. 49 CFR 173.163 - Hydrogen fluoride.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Hydrogen fluoride. 173.163 Section 173.163... Hydrogen fluoride. (a) Hydrogen fluoride (hydrofluoric acid, anhydrous) must be packaged as follows: (1) In... filling ratio of 0.84. (b) A cylinder removed from hydrogen fluoride service must be condemned in...

  7. 49 CFR 173.163 - Hydrogen fluoride.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Hydrogen fluoride. 173.163 Section 173.163... Hydrogen fluoride. (a) Hydrogen fluoride (hydrofluoric acid, anhydrous) must be packaged as follows: (1) In... filling ratio of 0.84. (b) A cylinder removed from hydrogen fluoride service must be condemned in...

  8. Materials refining on the Moon

    NASA Astrophysics Data System (ADS)

    Landis, Geoffrey A.

    2007-05-01

    Oxygen, metals, silicon, and glass are raw materials that will be required for long-term habitation and production of structural materials and solar arrays on the Moon. A process sequence is proposed for refining these materials from lunar regolith, consisting of separating the required materials from lunar rock with fluorine. The fluorine is brought to the Moon in the form of potassium fluoride, and is liberated from the salt by electrolysis in a eutectic salt melt. Tetrafluorosilane produced by this process is reduced to silicon by a plasma reduction stage; the fluorine salts are reduced to metals by reaction with metallic potassium. Fluorine is recovered from residual MgF and CaF2 by reaction with K2O.

  9. Fluoridation and Defluoridation. Training Module 2.230.2.77.

    ERIC Educational Resources Information Center

    McMullen, L. D.

    This document is an instructional module package prepared in objective form for use by an instructor familiar with fluoridation and fluoride feeding equipment. Enclosed are objectives, an instructor guide, student handouts and transparency masters. The module considers the principles and purposes of fluoridation, methods of feeding fluoride,…

  10. 21 CFR 355.70 - Testing procedures for fluoride dentifrice drug products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Testing procedures for fluoride dentifrice drug... Procedures § 355.70 Testing procedures for fluoride dentifrice drug products. (a) A fluoride dentifrice drug... tests: Enamel solubility reduction or fluoride enamel uptake. The testing procedures for these...

  11. 21 CFR 355.70 - Testing procedures for fluoride dentifrice drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Testing procedures for fluoride dentifrice drug... Procedures § 355.70 Testing procedures for fluoride dentifrice drug products. (a) A fluoride dentifrice drug... tests: Enamel solubility reduction or fluoride enamel uptake. The testing procedures for these...

  12. Design Manual: Removal of Fluoride from Drinking Water ...

    EPA Pesticide Factsheets

    This document is an updated version of the Design Manual: Removal of Fluoride from Drinking Water Supplies by Activated Alumina (Rubel, 1984). The manual is an in-depth presentation of the steps required to design and operate a fluoride removal plant using activated alumina (AA), which is a reliable and cost-effective process for treating excess fluoride from drinking water supplies. Design Manual on removing fluoride from drinking water to support the fluoride MCL - manual

  13. Copper Mediated Fluorination of Aryl Iodides

    PubMed Central

    Fier, Patrick S.; Hartwig, John F.

    2012-01-01

    The synthesis of aryl fluorides has been a topic of considerable interest because of the importance of aryl fluorides in pharmaceuticals, agrochemicals and materials. The stability, reactivity and biological properties of aryl fluorides can be distinct from those of the corresponding arenes. Methods for the synthesis of aryl fluorides, however, are limited. We report the conversion of a diverse set of aryl iodides to the corresponding aryl fluorides. This reaction occurs with a cationic copper reagent and silver fluoride. Preliminary results suggest this reaction is enabled by a facile reductive elimination from a cationic aryl copper(III) fluoride. PMID:22709145

  14. Fluoride Binding to Dental Biofilm Bacteria: Synergistic Effect with Calcium Questioned.

    PubMed

    Nóbrega, Diego Figueiredo; Leitão, Tarcísio Jorge; Cury, Jaime Aparecido; Tenuta, Livia Maria Andaló

    2018-06-06

    It has been suggested that fluoride binding to dental biofilm is enhanced when more bacterial calcium binding sites are available. However, this was only observed at high calcium and fluoride concentrations (i.e., when CaF2 precipitation may have occurred). We assessed fluoride binding to Streptococcus mutans pellets treated with calcium and fluoride at concentrations allowing CaF2 precipitation or not. Increasing calcium concentration resulted in a linear increase (p < 0.01) in fluoride concentration only in the pellets in which CaF2 precipitated. The results suggest that CaF2 precipitation, rather than bacterially bound fluoride, is responsible for the increase in fluoride binding to dental biofilm with the increase in calcium availability. © 2018 S. Karger AG, Basel.

  15. Small Molecule Fluoride Toxicity Agonists

    PubMed Central

    Nelson1, James W.; Plummer, Mark S.; Blount, Kenneth F.; Ames, Tyler D.; Breaker, Ronald R.

    2015-01-01

    SUMMARY Fluoride is a ubiquitous anion that inhibits a wide variety of metabolic processes. Here we report the identification of a series of compounds that enhance fluoride toxicity in Escherichia coli and Streptococcus mutans. These molecules were isolated by using a high-throughput screen (HTS) for compounds that increase intracellular fluoride levels as determined via a fluoride riboswitch-reporter fusion construct. A series of derivatives were synthesized to examine structure-activity relationships, leading to the identification of compounds with improved activity. Thus, we demonstrate that small molecule fluoride toxicity agonists can be identified by HTS from existing chemical libraries by exploiting a natural fluoride riboswitch. In addition, our findings suggest that some molecules might be further optimized to function as binary antibacterial agents when combined with fluoride. PMID:25910244

  16. Corrosion Behavior of Titanium Grade 7 in Fluoride-Containing NaCl Brines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lian, T; Whalen, M T; Wong, L

    2004-10-25

    The effects of fluoride on the corrosion behavior of Titanium Grade 7 (0.12-0.25% Pd) have been investigated. Up to 0.1 mol/L fluoride was added to the NaCl brines at 95 C, and three pH values of 4, 8, and 11 were selected for studying pH dependence of fluoride effects. It was observed that fluoride significantly altered the anodic polarization behavior, at all three pH values of 4, 8, and 11. Under acidic condition fluoride caused active corrosion. The corrosion of Titanium grade 7 was increased by three orders of magnitude when a 0.1 mol/L fluoride was added to the NaClmore » brines at pH 4, and the Pd ennoblement effect was not observed in acidic fluoride-containing environments. The effects of fluoride were reduced significantly when pH was increased to 8 and above.« less

  17. Global water fluoridation: what is holding us back?

    PubMed

    Botchey, Sally-Ann; Ouyang, Jing; Vivekanantham, Sayinthen

    2015-01-01

    Artificial water fluoridation was introduced more than 60 y ago as a public health intervention to control dental caries. Despite wide recommendations for its use from the World Health Organization (WHO) and studies showing the benefits of water fluoridation, many countries have opted out. Currently, only 25 countries, including the United Kingdom, the United States, and Australia have schemes for artificial water fluoridation. The issues faced in efforts to promote the global uptake of water fluoridation and the factors that affect the decision to implement it are unique in both developed and developing countries and must be explored. This article addresses the benefits and challenges of artificial water fluoridation. Further, it tackles the complexities faced with uptake of water fluoridation globally, such as ethical and political controversies and the use of alternative fluoride therapies. Potential future strategies to encourage the uptake of artificial water fluoridation are also discussed.

  18. Controlling the fluoride dosage in a patient with compromised salivary function.

    PubMed

    Eichmiller, Frederick C; Eidelman, Naomi; Carey, Clifton M

    2005-01-01

    High-concentration topical fluorides are used commonly to with compromised salivary function due to irradiation and chemotherapy. The authors describe a 50-year-old man with previously treated cancer who was using tray-applied topical fluoride gel. He complained of gastric symptoms, difficulty in swallowing, leg muscle soreness and knee joint soreness. A computed tomographic scan revealed thickening of the esophageal walls. An upper endoscopy revealed abnormal motility. The motility test indicated high-amplitude peristalsis and hypertensive lower esophageal sphincter, and urine testing indicated high levels of systemic fluoride. The patient's fluoride regimen was altered, and within a short period his urinary fluoride levels returned to normal and his symptoms resolved. Clinicians prescribing home-applied high-concentration fluorides need to be cognizant of the symptoms of fluoride toxicity, carefully monitor the patient's compliance with the treatment regimen, and adjust the dosage or mode of application to control the total ingested dose of fluoride.

  19. Water fluoridation and oral health.

    PubMed

    Harding, Máiréad Antoinette; O'Mullane, Denis Martin

    2013-11-01

    Water fluoridation, is the controlled addition of fluoride to the water supply, with the aim of reducing the prevalence of dental caries. Current estimates suggest that approximately 370 million people in 27 countries consume fluoridated water, with an additional 50 million consuming water in which fluoride is naturally occurring. A pre-eruptive effect of fluoride exists in reducing caries levels in pit and fissure surfaces of permanent teeth and fluoride concentrated in plaque and saliva inhibits the demineralisation of sound enamel and enhances the remineralisation of demineralised enamel. A large number of studies conducted worldwide demonstrate the effectiveness of water fluoridation. Objections to water fluoridation have been raised since its inception and centre mainly on safety and autonomy. Systematic reviews of the safety and efficacy of water fluoridation attest to its safety and efficacy; dental fluorosis identified as the only adverse outcome. Water fluoridation is an effective safe means of preventing dental caries, reaching all populations, irrespective of the presence of other dental services. Regular monitoring of dental caries and fluorosis is essential particularly with the lifelong challenge which dental caries presents. Copyright © 2013 by Academy of Sciences and Arts of Bosnia and Herzegovina.

  20. Fluoridation advocacy in Queensland: a long and winding road.

    PubMed

    Akers, Harry Francis; Foley, Michael Anthony

    2012-10-01

    By 1977, all Australian states and mainland territories, with the exception of Queensland, had widely implemented adjusted water fluoridation. This disparity in public health policy persisted until 2008. This study analyses the sociopolitical and socioeconomic backgrounds that underpinned the repeal of the Fluoridation of Public Water Supplies Act (1963) and its replacement with the Water Fluoridation Act (2008). The authors used a literature review and historic method. References are in the public domain. The devolution, without funding, of a discretionary local authority power to fluoridate contributed to the perennial low fluoridation status in Queensland. A window of opportunity for fluoridation advocates opened between 2003 and 2008. Now that 87% of Queenslanders have access to optimally fluoridated water, Queensland premier Anna Bligh has largely delivered on a promise made in 2007 to fluoridate water supplies across the state. The implementation of adjusted water fluoridation requires not only political stability and resolve, but also centralised authority. The last of these factors must embrace the decision, the funding and the indemnity. State control over water-related infrastructure and water treatment enhances prospects for fluoridation. The roles of opinion polls, internal advisers and departmental figures are also confirmed. Political repercussions were minimal. © 2012 FDI World Dental Federation.

Top