Sample records for based room correction

  1. Quality assurance for kilo- and megavoltage in-room imaging and localization for off- and online setup error correction.

    PubMed

    Balter, James M; Antonuk, Larry E

    2008-01-01

    In-room radiography is not a new concept for image-guided radiation therapy. Rapid advances in technology, however, have made this positioning method convenient, and thus radiograph-based positioning has propagated widely. The paradigms for quality assurance of radiograph-based positioning include imager performance, systems integration, infrastructure, procedure documentation and testing, and support for positioning strategy implementation.

  2. A comparative study between the imaging system and the optical tracking system in proton therapy at CNAO

    PubMed Central

    Desplanques, Maxime; Tagaste, Barbara; Fontana, Giulia; Pella, Andrea; Riboldi, Marco; Fattori, Giovanni; Donno, Andrea; Baroni, Guido; Orecchia, Roberto

    2013-01-01

    The synergy between in-room imaging and optical tracking, in co-operation with highly accurate robotic patient handling represents a concept for patient-set-up which has been implemented at CNAO (Centro Nazionale di Adroterapia Oncologica). In-room imaging is based on a double oblique X-ray projection system; optical tracking consists of the detection of the position of spherical markers placed directly on the patient's skin or on the immobilization devices. These markers are used as external fiducials during patient positioning and dose delivery. This study reports the results of a comparative analysis between in-room imaging and optical tracking data for patient positioning within the framework of high-precision particle therapy. Differences between the optical tracking system (OTS) and the imaging system (IS) were on average within the expected localization accuracy. On the first 633 fractions for head and neck (H&N) set-up procedures, the corrections applied by the IS, after patient positioning using the OTS only, were for the mostly sub-millimetric regarding the translations (0.4±1.1 mm) and sub-gradual regarding the rotations (0.0°±0.8°). On the first 236 fractions for pelvis localizations the amplitude of the corrections applied by the IS after preliminary optical set-up correction were moderately higher and more dispersed (translations: 1.3±2.9 mm, rotations 0.1±0.9°). Although the indication of the OTS cannot replace information provided by in-room imaging devices and 2D-3D image registration, the reported data show that OTS preliminary correction might greatly support image-based patient set-up refinement and also provide a secondary, independent verification system for patient positioning. PMID:23824116

  3. 75 FR 5536 - Pipeline Safety: Control Room Management/Human Factors, Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-03

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Parts...: Control Room Management/Human Factors, Correction AGENCY: Pipeline and Hazardous Materials Safety... following correcting amendments: PART 192--TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM...

  4. Reverberant acoustic energy in auditoria that comprise systems of coupled rooms

    NASA Astrophysics Data System (ADS)

    Summers, Jason E.

    2003-11-01

    A frequency-dependent model for reverberant energy in coupled rooms is developed and compared with measurements for a 1:10 scale model and for Bass Hall, Ft. Worth, TX. At high frequencies, prior statistical-acoustics models are improved by geometrical-acoustics corrections for decay within sub-rooms and for energy transfer between sub-rooms. Comparisons of computational geometrical acoustics predictions based on beam-axis tracing with scale model measurements indicate errors resulting from tail-correction assuming constant quadratic growth of reflection density. Using ray tracing in the late part corrects this error. For mid-frequencies, the models are modified to account for wave effects at coupling apertures by including power transmission coefficients. Similarly, statical-acoustics models are improved through more accurate estimates of power transmission measurements. Scale model measurements are in accord with the predicted behavior. The edge-diffraction model is adapted to study transmission through apertures. Multiple-order scattering is theoretically and experimentally shown inaccurate due to neglect of slope diffraction. At low frequencies, perturbation models qualitatively explain scale model measurements. Measurements confirm relation of coupling strength to unperturbed pressure distribution on coupling surfaces. Measurements in Bass Hall exhibit effects of the coupled stage house. High frequency predictions of statistical acoustics and geometrical acoustics models and predictions of coupling apertures all agree with measurements.

  5. [Design and Implementation of a Mobile Operating Room Information Management System Based on Electronic Medical Record].

    PubMed

    Liu, Baozhen; Liu, Zhiguo; Wang, Xianwen

    2015-06-01

    A mobile operating room information management system with electronic medical record (EMR) is designed to improve work efficiency and to enhance the patient information sharing. In the operating room, this system acquires the information from various medical devices through the Client/Server (C/S) pattern, and automatically generates XML-based EMR. Outside the operating room, this system provides information access service by using the Browser/Server (B/S) pattern. Software test shows that this system can correctly collect medical information from equipment and clearly display the real-time waveform. By achieving surgery records with higher quality and sharing the information among mobile medical units, this system can effectively reduce doctors' workload and promote the information construction of the field hospital.

  6. Effect of an Ergonomics-Based Educational Intervention Based on Transtheoretical Model in Adopting Correct Body Posture Among Operating Room Nurses

    PubMed Central

    Moazzami, Zeinab; Dehdari, Tahere; Taghdisi, Mohammad Hosein; Soltanian, Alireza

    2016-01-01

    Background: One of the preventive strategies for chronic low back pain among operating room nurses is instructing proper body mechanics and postural behavior, for which the use of the Transtheoretical Model (TTM) has been recommended. Methods: Eighty two nurses who were in the contemplation and preparation stages for adopting correct body posture were randomly selected (control group = 40, intervention group = 42). TTM variables and body posture were measured at baseline and again after 1 and 6 months after the intervention. A four-week ergonomics educational intervention based on TTM variables was designed and conducted for the nurses in the intervention group. Results: Following the intervention, a higher proportion of nurses in the intervention group moved into the action stage (p < 0.05). Mean scores of self-efficacy, pros, experimental processes and correct body posture were also significantly higher in the intervention group (p < 0.05). No significant differences were found in the cons and behavioral processes, except for self-liberation, between the two groups (p > 0.05) after the intervention. Conclusions: The TTM provides a suitable framework for developing stage-based ergonomics interventions for postural behavior. PMID:26925897

  7. Effect of an Ergonomics-Based Educational Intervention Based on Transtheoretical Model in Adopting Correct Body Posture Among Operating Room Nurses.

    PubMed

    Moazzami, Zeinab; Dehdari, Tahere; Taghdisi, Mohammad Hosein; Soltanian, Alireza

    2015-11-03

    One of the preventive strategies for chronic low back pain among operating room nurses is instructing proper body mechanics and postural behavior, for which the use of the Transtheoretical Model (TTM) has been recommended. Eighty two nurses who were in the contemplation and preparation stages for adopting correct body posture were randomly selected (control group = 40, intervention group = 42). TTM variables and body posture were measured at baseline and again after 1 and 6 months after the intervention. A four-week ergonomics educational intervention based on TTM variables was designed and conducted for the nurses in the intervention group. Following the intervention, a higher proportion of nurses in the intervention group moved into the action stage (p < 0.05). Mean scores of self-efficacy, pros, experimental processes and correct body posture were also significantly higher in the intervention group (p < 0.05). No significant differences were found in the cons and behavioral processes, except for self-liberation, between the two groups (p > 0.05) after the intervention. The TTM provides a suitable framework for developing stage-based ergonomics interventions for postural behavior.

  8. Are we fully utilizing the functionalities of modern operating room ventilators?

    PubMed

    Liu, Shujie; Kacmarek, Robert M; Oto, Jun

    2017-12-01

    The modern operating room ventilators have become very sophisticated and many of their features are comparable with those of an ICU ventilator. To fully utilize the functionality of modern operating room ventilators, it is important for clinicians to understand in depth the working principle of these ventilators and their functionalities. Piston ventilators have the advantages of delivering accurate tidal volume and certain flow compensation functions. Turbine ventilators have great ability of flow compensation. Ventilation modes are mainly volume-based or pressure-based. Pressure-based ventilation modes provide better leak compensation than volume-based. The integration of advanced flow generation systems and ventilation modes of the modern operating room ventilators enables clinicians to provide both invasive and noninvasive ventilation in perioperative settings. Ventilator waveforms can be used for intraoperative neuromonitoring during cervical spine surgery. The increase in number of new features of modern operating room ventilators clearly creates the opportunity for clinicians to optimize ventilatory care. However, improving the quality of ventilator care relies on a complete understanding and correct use of these new features. VIDEO ABSTRACT: http://links.lww.com/COAN/A47.

  9. Near field communication (NFC) model for arduino uno based security systems office system

    NASA Astrophysics Data System (ADS)

    Chairunnas, A.; Abdurrasyid, I.

    2018-03-01

    Currently, many offices or companies that start growing rapidly in a company or office should have a very limited room to enter only people entitled to enter the room and use the facilities contained in it, for example, Files in it must have many files and documents very important because to reduce the abuse of files and irresponsible person. Because it will be made room door security system by using Near Field Communication on android smartphone. Software used is Arduino IDE. The tools used in this system are Arduino Uno R3, NFC shield, pear sensor, bell, led, servo, 16 × 2 LCD, and Near Field Communication (NFC) in android smartphone. This system runs based on 2 inputs of a new technology that is Near Field Communication (NFC) in android smartphone. And also use pear sensor to detect unauthorized person entering the room. If the correct password is entered then the door will open and the pear sensor will light off if wrong then the bell will light up.

  10. Perceptually relevant parameters for virtual listening simulation of small room acoustics

    PubMed Central

    Zahorik, Pavel

    2009-01-01

    Various physical aspects of room-acoustic simulation techniques have been extensively studied and refined, yet the perceptual attributes of the simulations have received relatively little attention. Here a method of evaluating the perceptual similarity between rooms is described and tested using 15 small-room simulations based on binaural room impulse responses (BRIRs) either measured from a real room or estimated using simple geometrical acoustic modeling techniques. Room size and surface absorption properties were varied, along with aspects of the virtual simulation including the use of individualized head-related transfer function (HRTF) measurements for spatial rendering. Although differences between BRIRs were evident in a variety of physical parameters, a multidimensional scaling analysis revealed that when at-the-ear signal levels were held constant, the rooms differed along just two perceptual dimensions: one related to reverberation time (T60) and one related to interaural coherence (IACC). Modeled rooms were found to differ from measured rooms in this perceptual space, but the differences were relatively small and should be easily correctable through adjustment of T60 and IACC in the model outputs. Results further suggest that spatial rendering using individualized HRTFs offers little benefit over nonindividualized HRTF rendering for room simulation applications where source direction is fixed. PMID:19640043

  11. Fracture Sustainability Pressure, Temperature, Differential Pressure, and Aperture Closure Data

    DOE Data Explorer

    Tim Kneafsey

    2016-09-30

    In these data sets, the experiment time, actual date and time, room temperature, sample temperature, upstream and downstream pressures (measured independently), corrected differential pressure (measured independently and corrected for offset and room temperature) indication of aperture closure by linear variable differential transformer are presented. An indication of the sample is in the file name and in the first line of data.

  12. [Basic research on digital logistic management of hospital].

    PubMed

    Cao, Hui

    2010-05-01

    This paper analyzes and explores the possibilities of digital information-based management realized by equipment department, general services department, supply room and other material flow departments in different hospitals in order to optimize the procedures of information-based asset management. There are various analytical methods of medical supplies business models, providing analytical data for correct decisions made by departments and leaders of hospital and the governing authorities.

  13. 32 CFR 865.106 - Application for review.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Veterans Administration, or by writing to: DA Military Review Boards Agency, Attention: SFBA (Reading Room...'s benefit to bring such issues to the DRB's attention as early as possible in the review, applicants... (including decisions maintained by the Armed Forces Discharge Review Board/Correction Board Reading Room...

  14. 32 CFR 865.106 - Application for review.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Veterans Administration, or by writing to: DA Military Review Boards Agency, Attention: SFBA (Reading Room...'s benefit to bring such issues to the DRB's attention as early as possible in the review, applicants... (including decisions maintained by the Armed Forces Discharge Review Board/Correction Board Reading Room...

  15. 32 CFR 865.106 - Application for review.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Veterans Administration, or by writing to: DA Military Review Boards Agency, Attention: SFBA (Reading Room...'s benefit to bring such issues to the DRB's attention as early as possible in the review, applicants... (including decisions maintained by the Armed Forces Discharge Review Board/Correction Board Reading Room...

  16. 32 CFR 865.106 - Application for review.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Veterans Administration, or by writing to: DA Military Review Boards Agency, Attention: SFBA (Reading Room...'s benefit to bring such issues to the DRB's attention as early as possible in the review, applicants... (including decisions maintained by the Armed Forces Discharge Review Board/Correction Board Reading Room...

  17. Temperature correction of arterial blood-gas parameters: A comparative review of methodology.

    PubMed

    Andritsch, R F; Muravchick, S; Gold, M I

    1981-09-01

    The need for accurate clinical diagnosis and appropriate intervention requires that a modern blood-gas laboratory have the means to correct for significant discrepancies between patient temperature and the temperature at which in vitro blood samples are analyzed. Recent advances in mini- and microcomputer technology permit application of any or all of the correction formulas above at modest cost and minimal inconvenience (See the Appendix). An expanded program for a TI-59 desk-top calculator and P-100C printer which gives labeled hard-copy readout of temperature-corrected pH, PCO2, PO2, and hemoglobin saturation values, as well as bicarbonate concentration and in vivo base excess is in daily clinical use in our operating room and is available from the authors upon request.

  18. Reverberant acoustic energy in auditoria that comprise systems of coupled rooms

    NASA Astrophysics Data System (ADS)

    Summers, Jason Erik

    A frequency-dependent model for levels and decay rates of reverberant energy in systems of coupled rooms is developed and compared with measurements conducted in a 1:10 scale model and in Bass Hall, Fort Worth, TX. Schroeder frequencies of subrooms, fSch, characteristic size of coupling apertures, a, relative to wavelength lambda, and characteristic size of room surfaces, l, relative to lambda define the frequency regions. At high frequencies [HF (f >> f Sch, a >> lambda, l >> lambda)], this work improves upon prior statistical-acoustics (SA) coupled-ODE models by incorporating geometrical-acoustics (GA) corrections for the model of decay within subrooms and the model of energy transfer between subrooms. Previous researchers developed prediction algorithms based on computational GA. Comparisons of predictions derived from beam-axis tracing with scale-model measurements indicate that systematic errors for coupled rooms result from earlier tail-correction procedures that assume constant quadratic growth of reflection density. A new algorithm is developed that uses ray tracing rather than tail correction in the late part and is shown to correct this error. At midfrequencies [MF (f >> f Sch, a ˜ lambda)], HF models are modified to account for wave effects at coupling apertures by including analytically or heuristically derived power transmission coefficients tau. This work improves upon prior SA models of this type by developing more accurate estimates of random-incidence tau. While the accuracy of the MF models is difficult to verify, scale-model measurements evidence the expected behavior. The Biot-Tolstoy-Medwin-Svensson (BTMS) time-domain edge-diffraction model is newly adapted to study transmission through apertures. Multiple-order BTMS scattering is theoretically and experimentally shown to be inaccurate due to the neglect of slope diffraction. At low frequencies (f ˜ f Sch), scale-model measurements have been qualitatively explained by application of previously developed perturbation models. Measurements newly confirm that coupling strength between three-dimensional rooms is related to unperturbed pressure distribution on the coupling surface. In Bass Hall, measurements are conducted to determine the acoustical effects of the coupled stage house on stage and in the audience area. The high-frequency predictions of statistical- and geometrical-acoustics models agree well with measured results. Predictions of the transmission coefficients of the coupling apertures agree, at least qualitatively, with the observed behavior.

  19. Baffling or Baffled: Improve Your Acoustics.

    ERIC Educational Resources Information Center

    Abdoo, Frank B.

    1981-01-01

    Presents techniques for evaluating the acoustics (reverberation time, and standing waves and resonance phenomena) of a band performance room. Gives instructions for building and placing inexpensive baffles (free-standing, portable sound barriers) to correct room defects. (SJL)

  20. Display Developer for Firing Room Applications

    NASA Technical Reports Server (NTRS)

    Bowman, Elizabeth A.

    2013-01-01

    The firing room at Kennedy Space Center (KSC) is responsible for all NASA human spaceflight launch operations, therefore it is vital that all displays within the firing room be properly tested, up-to-date, and user-friendly during a launch. The Ground Main Propulsion System (GMPS) requires a number of remote displays for Vehicle Integration and Launch (VIL) Operations at KSC. My project is to develop remote displays for the GMPS using the Display Services and Framework (DSF) editor. These remote displays will be based on model images provided by GMPS through PowerPoint. Using the DSF editor, the PowerPoint images can be recreated with active buttons associated with the correct Compact Unique Identifiers (CUIs). These displays will be documented in the Software Requirements and Design Specifications (SRDS) at the 90% GMPS Design Review. In the future, these remote displays will be available for other developers to improve, edit, or add on to so that the display may be incorporated into the firing room to be used for launches.

  1. Thermal transmission of camouflage nets revisited

    NASA Astrophysics Data System (ADS)

    Jersblad, Johan; Jacobs, Pieter

    2016-10-01

    In this article we derive, from first principles, the correct formula for thermal transmission of a camouflage net, based on the setup described in the US standard for lightweight camouflage nets. Furthermore, we compare the results and implications with the use of an incorrect formula that have been seen in several recent tenders. It is shown that the incorrect formulation not only gives rise to large errors, but the result also depends on the surrounding room temperature, which in the correct derivation cancels out. The theoretical results are compared with laboratory measurements. The theoretical results agree with the laboratory results for the correct derivation. To summarize we discuss the consequences for soldiers on the battlefield if incorrect standards and test methods are used in procurement processes.

  2. Evaluation of corrective measures implemented for the preventive conservation of fresco paintings in Ariadne’s house (Pompeii, Italy)

    PubMed Central

    2013-01-01

    Background A microclimate monitoring study was conducted in 2008 aimed at assessing the conservation risks affecting the valuable wall paintings decorating Ariadne’s House (Pompeii, Italy). It was found that thermohygrometric conditions were very unfavorable for the conservation of frescoes. As a result, it was decided to implement corrective measures, and the transparent polycarbonate sheets covering three rooms (one of them delimited by four walls and the others composed of three walls) were replaced by opaque roofs. In order to examine the effectiveness of this measure, the same monitoring system comprised by 26 thermohygrometric probes was installed again in summer 2010. Data recorded in 2008 and 2010 were compared. Results Microclimate conditions were also monitored in a control room with the same roof in both years. The average temperature in this room was lower in 2010, and it was decided to consider a time frame of 18 summer days with the same mean temperature in both years. In the rooms with three walls, the statistical analysis revealed that the diurnal maximum temperature decreased about 3.5°C due to the roof change, and the minimum temperature increased 0.5°C. As a result, the daily thermohygrometric variations resulted less pronounced in 2010, with a reduction of approximately 4°C, which is favorable for the preservation of mural paintings. In the room with four walls, the daily fluctuations also decreased about 4°C. Based on the results, other alternative actions are discussed aimed at improving the conservation conditions of wall paintings. Conclusions The roof change has reduced the most unfavorable thermohygrometric conditions affecting the mural paintings, but additional actions should be adopted for a long term preservation of Pompeian frescoes. PMID:23683173

  3. Evaluation of corrective measures implemented for the preventive conservation of fresco paintings in Ariadne's house (Pompeii, Italy).

    PubMed

    Merello, Paloma; García-Diego, Fernando-Juan; Zarzo, Manuel

    2013-05-17

    A microclimate monitoring study was conducted in 2008 aimed at assessing the conservation risks affecting the valuable wall paintings decorating Ariadne's House (Pompeii, Italy). It was found that thermohygrometric conditions were very unfavorable for the conservation of frescoes. As a result, it was decided to implement corrective measures, and the transparent polycarbonate sheets covering three rooms (one of them delimited by four walls and the others composed of three walls) were replaced by opaque roofs. In order to examine the effectiveness of this measure, the same monitoring system comprised by 26 thermohygrometric probes was installed again in summer 2010. Data recorded in 2008 and 2010 were compared. Microclimate conditions were also monitored in a control room with the same roof in both years. The average temperature in this room was lower in 2010, and it was decided to consider a time frame of 18 summer days with the same mean temperature in both years. In the rooms with three walls, the statistical analysis revealed that the diurnal maximum temperature decreased about 3.5°C due to the roof change, and the minimum temperature increased 0.5°C. As a result, the daily thermohygrometric variations resulted less pronounced in 2010, with a reduction of approximately 4°C, which is favorable for the preservation of mural paintings. In the room with four walls, the daily fluctuations also decreased about 4°C. Based on the results, other alternative actions are discussed aimed at improving the conservation conditions of wall paintings. The roof change has reduced the most unfavorable thermohygrometric conditions affecting the mural paintings, but additional actions should be adopted for a long term preservation of Pompeian frescoes.

  4. 33 CFR 52.81 - Reading room and index.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Reading room and index. 52.81 Section 52.81 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PERSONNEL BOARD FOR CORRECTION OF MILITARY RECORDS OF THE COAST GUARD Public Access to Decisions § 52.81 Reading room and index. After deleting only so much...

  5. 33 CFR 52.81 - Reading room and index.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Reading room and index. 52.81 Section 52.81 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PERSONNEL BOARD FOR CORRECTION OF MILITARY RECORDS OF THE COAST GUARD Public Access to Decisions § 52.81 Reading room and index. After deleting only so much...

  6. 33 CFR 52.81 - Reading room and index.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Reading room and index. 52.81 Section 52.81 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PERSONNEL BOARD FOR CORRECTION OF MILITARY RECORDS OF THE COAST GUARD Public Access to Decisions § 52.81 Reading room and index. After deleting only so much...

  7. 33 CFR 52.81 - Reading room and index.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Reading room and index. 52.81 Section 52.81 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PERSONNEL BOARD FOR CORRECTION OF MILITARY RECORDS OF THE COAST GUARD Public Access to Decisions § 52.81 Reading room and index. After deleting only so much...

  8. 33 CFR 52.81 - Reading room and index.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Reading room and index. 52.81 Section 52.81 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PERSONNEL BOARD FOR CORRECTION OF MILITARY RECORDS OF THE COAST GUARD Public Access to Decisions § 52.81 Reading room and index. After deleting only so much...

  9. 32 CFR 865.118 - Availability of Discharge Review Board documents for public inspection and copying.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Board Agency, Attention: SFBA (Reading Room), Room 1E520, The Pentagon, Washington DC 20310 ... and copying shall be located in the Armed Forces Discharge Review/Correction Boards Reading Room. The... or the Secretary of the Air Force granted or denied relief. (1) The reading file index shall include...

  10. 76 FR 4601 - Determinations Concerning Need for Error Correction, Partial Approval and Partial Disapproval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-26

    ... submitting comments. E-mail: epa.gov ">[email protected] epa.gov . Fax: (202) 566-9744. Mail: Attention Docket..., Room 3334, Washington, DC 20004, Attention Docket ID No. EPA-HQ-OAR-2010-1033. Such deliveries are only..., EPA West Building, Room 3334, 1301 Constitution Ave., NW., Washington, DC. The Public Reading Room is...

  11. Automatic detection and notification of "wrong patient-wrong location'' errors in the operating room.

    PubMed

    Sandberg, Warren S; Häkkinen, Matti; Egan, Marie; Curran, Paige K; Fairbrother, Pamela; Choquette, Ken; Daily, Bethany; Sarkka, Jukka-Pekka; Rattner, David

    2005-09-01

    When procedures and processes to assure patient location based on human performance do not work as expected, patients are brought incrementally closer to a possible "wrong patient-wrong procedure'' error. We developed a system for automated patient location monitoring and management. Real-time data from an active infrared/radio frequency identification tracking system provides patient location data that are robust and can be compared with an "expected process'' model to automatically flag wrong-location events as soon as they occur. The system also generates messages that are automatically sent to process managers via the hospital paging system, thus creating an active alerting function to annunciate errors. We deployed the system to detect and annunciate "patient-in-wrong-OR'' events. The system detected all "wrong-operating room (OR)'' events, and all "wrong-OR'' locations were correctly assigned within 0.50+/-0.28 minutes (mean+/-SD). This corresponded to the measured latency of the tracking system. All wrong-OR events were correctly annunciated via the paging function. This experiment demonstrates that current technology can automatically collect sufficient data to remotely monitor patient flow through a hospital, provide decision support based on predefined rules, and automatically notify stakeholders of errors.

  12. A method of measuring and correcting tilt of anti - vibration wind turbines based on screening algorithm

    NASA Astrophysics Data System (ADS)

    Xiao, Zhongxiu

    2018-04-01

    A Method of Measuring and Correcting Tilt of Anti - vibration Wind Turbines Based on Screening Algorithm is proposed in this paper. First of all, we design a device which the core is the acceleration sensor ADXL203, the inclination is measured by installing it on the tower of the wind turbine as well as the engine room. Next using the Kalman filter algorithm to filter effectively by establishing a state space model for signal and noise. Then we use matlab for simulation. Considering the impact of the tower and nacelle vibration on the collected data, the original data and the filtering data are classified and stored by the Screening algorithm, then filter the filtering data to make the output data more accurate. Finally, we eliminate installation errors by using algorithm to achieve the tilt correction. The device based on this method has high precision, low cost and anti-vibration advantages. It has a wide range of application and promotion value.

  13. Opinions of Female Juvenile Delinquents about Their Interactions in Chat Rooms

    ERIC Educational Resources Information Center

    Sanger, Dixie; Long, Amie; Ritzman, Mitzi; Stofer, Keri; Davis, Candy

    2004-01-01

    The purpose of this study was to survey the opinions of 62 adolescent females residing in a correctional facility about their use of the Internet to participate in chat room conversations. Findings indicated that 54 of 62 girls (87.09%), with a mean age of 16.72 years, participated in chat room interactions. Most (n = 47) interacted in chat rooms…

  14. Line Coupling Effects in the Isotropic Raman Spectra of N2: A Quantum Calculation at Room Temperature

    NASA Technical Reports Server (NTRS)

    Thibault, Franck; Boulet, Christian; Ma, Qiancheng

    2014-01-01

    We present quantum calculations of the relaxation matrix for the Q branch of N2 at room temperature using a recently proposed N2-N2 rigid rotor potential. Close coupling calculations were complemented by coupled states studies at high energies and provide about 10200 two-body state-to state cross sections from which the needed one-body cross-sections may be obtained. For such temperatures, convergence has to be thoroughly analyzed since such conditions are close to the limit of current computational feasibility. This has been done using complementary calculations based on the energy corrected sudden formalism. Agreement of these quantum predictions with experimental data is good, but the main goal of this work is to provide a benchmark relaxation matrix for testing more approximate methods which remain of a great utility for complex molecular systems at room (and higher) temperatures.

  15. Study of the Factors Affecting the Mathematics Achievement of Turkish Students According to Data from the Programme for International Student Assessment (PISA) 2012

    ERIC Educational Resources Information Center

    Güzeller, Cem Oktay; Eser, Mehmet Taha; Aksu, Gökhan

    2016-01-01

    This study attempts to determine the factors affecting the mathematics achievement of students in Turkey based on data from the Programme for International Student Assessment 2012 and the correct classification ratio of the established model. The study used mathematics achievement as a dependent variable while sex, having a study room, preparation…

  16. SU-F-P-18: Development of the Technical Training System for Patient Set-Up Considering Rotational Correction in the Virtual Environment Using Three-Dimensional Computer Graphic Engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Imura, K; Fujibuchi, T; Hirata, H

    Purpose: Patient set-up skills in radiotherapy treatment room have a great influence on treatment effect for image guided radiotherapy. In this study, we have developed the training system for improving practical set-up skills considering rotational correction in the virtual environment away from the pressure of actual treatment room by using three-dimensional computer graphic (3DCG) engine. Methods: The treatment room for external beam radiotherapy was reproduced in the virtual environment by using 3DCG engine (Unity). The viewpoints to perform patient set-up in the virtual treatment room were arranged in both sides of the virtual operable treatment couch to assume actual performancemore » by two clinical staffs. The position errors to mechanical isocenter considering alignment between skin marker and laser on the virtual patient model were displayed by utilizing numerical values expressed in SI units and the directions of arrow marks. The rotational errors calculated with a point on the virtual body axis as the center of each rotation axis for the virtual environment were corrected by adjusting rotational position of the body phantom wound the belt with gyroscope preparing on table in a real space. These rotational errors were evaluated by describing vector outer product operations and trigonometric functions in the script for patient set-up technique. Results: The viewpoints in the virtual environment allowed individual user to visually recognize the position discrepancy to mechanical isocenter until eliminating the positional errors of several millimeters. The rotational errors between the two points calculated with the center point could be efficiently corrected to display the minimum technique mathematically by utilizing the script. Conclusion: By utilizing the script to correct the rotational errors as well as accurate positional recognition for patient set-up technique, the training system developed for improving patient set-up skills enabled individual user to indicate efficient positional correction methods easily.« less

  17. Correcting for Microbial Blooms in Fecal Samples during Room-Temperature Shipping.

    PubMed

    Amir, Amnon; McDonald, Daniel; Navas-Molina, Jose A; Debelius, Justine; Morton, James T; Hyde, Embriette; Robbins-Pianka, Adam; Knight, Rob

    2017-01-01

    The use of sterile swabs is a convenient and common way to collect microbiome samples, and many studies have shown that the effects of room-temperature storage are smaller than physiologically relevant differences between subjects. However, several bacterial taxa, notably members of the class Gammaproteobacteria , grow at room temperature, sometimes confusing microbiome results, particularly when stability is assumed. Although comparative benchmarking has shown that several preservation methods, including the use of 95% ethanol, fecal occult blood test (FOBT) and FTA cards, and Omnigene-GUT kits, reduce changes in taxon abundance during room-temperature storage, these techniques all have drawbacks and cannot be applied retrospectively to samples that have already been collected. Here we performed a meta-analysis using several different microbiome sample storage condition studies, showing consistent trends in which specific bacteria grew (i.e., "bloomed") at room temperature, and introduce a procedure for removing the sequences that most distort analyses. In contrast to similarity-based clustering using operational taxonomic units (OTUs), we use a new technique called "Deblur" to identify the exact sequences corresponding to blooming taxa, greatly reducing false positives and also dramatically decreasing runtime. We show that applying this technique to samples collected for the American Gut Project (AGP), for which participants simply mail samples back without the use of ice packs or other preservatives, yields results consistent with published microbiome studies performed with frozen or otherwise preserved samples. IMPORTANCE In many microbiome studies, the necessity to store samples at room temperature (i.e., remote fieldwork) and the ability to ship samples without hazardous materials that require special handling training, such as ethanol (i.e., citizen science efforts), is paramount. However, although room-temperature storage for a few days has been shown not to obscure physiologically relevant microbiome differences between comparison groups, there are still changes in specific bacterial taxa, notably, in members of the class Gammaproteobacteria , that can make microbiome profiles difficult to interpret. Here we identify the most problematic taxa and show that removing sequences from just a few fast-growing taxa is sufficient to correct microbiome profiles.

  18. Correcting for Microbial Blooms in Fecal Samples during Room-Temperature Shipping

    PubMed Central

    Amir, Amnon; McDonald, Daniel; Navas-Molina, Jose A.; Debelius, Justine; Morton, James T.; Hyde, Embriette; Robbins-Pianka, Adam

    2017-01-01

    ABSTRACT The use of sterile swabs is a convenient and common way to collect microbiome samples, and many studies have shown that the effects of room-temperature storage are smaller than physiologically relevant differences between subjects. However, several bacterial taxa, notably members of the class Gammaproteobacteria, grow at room temperature, sometimes confusing microbiome results, particularly when stability is assumed. Although comparative benchmarking has shown that several preservation methods, including the use of 95% ethanol, fecal occult blood test (FOBT) and FTA cards, and Omnigene-GUT kits, reduce changes in taxon abundance during room-temperature storage, these techniques all have drawbacks and cannot be applied retrospectively to samples that have already been collected. Here we performed a meta-analysis using several different microbiome sample storage condition studies, showing consistent trends in which specific bacteria grew (i.e., “bloomed”) at room temperature, and introduce a procedure for removing the sequences that most distort analyses. In contrast to similarity-based clustering using operational taxonomic units (OTUs), we use a new technique called “Deblur” to identify the exact sequences corresponding to blooming taxa, greatly reducing false positives and also dramatically decreasing runtime. We show that applying this technique to samples collected for the American Gut Project (AGP), for which participants simply mail samples back without the use of ice packs or other preservatives, yields results consistent with published microbiome studies performed with frozen or otherwise preserved samples. IMPORTANCE In many microbiome studies, the necessity to store samples at room temperature (i.e., remote fieldwork) and the ability to ship samples without hazardous materials that require special handling training, such as ethanol (i.e., citizen science efforts), is paramount. However, although room-temperature storage for a few days has been shown not to obscure physiologically relevant microbiome differences between comparison groups, there are still changes in specific bacterial taxa, notably, in members of the class Gammaproteobacteria, that can make microbiome profiles difficult to interpret. Here we identify the most problematic taxa and show that removing sequences from just a few fast-growing taxa is sufficient to correct microbiome profiles. PMID:28289733

  19. [Justifying measures to correct functional state of operators varying in personal anxiety].

    PubMed

    2012-01-01

    Workers of operating and dispatching occupations are exposed to high nervous and emotional exertion that result in increased personal anxiety, working stress and overstrain. That requires physiologically justified correction of hazardous psycho-physiologic states via various prophylactic measures (stay in schungite room, autogenous training, central electric analgesia, electric acupuncture). Attempted relaxation sessions in schungite room revealed in highly anxious individuals an increased velocity of visual signals perception, of attention concentration and shifting. Autogenous training sessions improve memory and have significant hypotensive effect in highly anxious individuals.

  20. Virtual operating room for team training in surgery.

    PubMed

    Abelson, Jonathan S; Silverman, Elliott; Banfelder, Jason; Naides, Alexandra; Costa, Ricardo; Dakin, Gregory

    2015-09-01

    We proposed to develop a novel virtual reality (VR) team training system. The objective of this study was to determine the feasibility of creating a VR operating room to simulate a surgical crisis scenario and evaluate the simulator for construct and face validity. We modified ICE STORM (Integrated Clinical Environment; Systems, Training, Operations, Research, Methods), a VR-based system capable of modeling a variety of health care personnel and environments. ICE STORM was used to simulate a standardized surgical crisis scenario, whereby participants needed to correct 4 elements responsible for loss of laparoscopic visualization. The construct and face validity of the environment were measured. Thirty-three participants completed the VR simulation. Attendings completed the simulation in less time than trainees (271 vs 201 seconds, P = .032). Participants felt the training environment was realistic and had a favorable impression of the simulation. All participants felt the workload of the simulation was low. Creation of a VR-based operating room for team training in surgery is feasible and can afford a realistic team training environment. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Verification of Exciton Effects in Organic Solar Cells at Low Temperatures Based on a Modified Numerical Model

    NASA Astrophysics Data System (ADS)

    Xiong, Chun-Hua; Sun, Jiu-Xun; Wang, Dai-Peng; Dong, Yan

    2018-02-01

    There are many models for researching charge transport in semiconductors and improving their performance. Most of them give good descriptions of the experimental data at room temperature. But it is still an open question which model is correct. In this paper, numerical calculations based on three modified versions of a classical model were made, and compared with experimental data for typical devices at room or low temperatures. Although their results are very similar to each other at room temperatures, only the version considering exciton effects by using a hydrogen-like model can give qualitative descriptions to recent experimental data at low temperatures. Moreover, the mobility was researched in detail by comparing the constant model and temperature dependence model. Then, we found the performance increases with the mobility of each charge carrier type being independent to the mobility of the other one. This paper provides better insight into understanding the physical mechanism of carrier transport in semiconductors, and the results show that exciton effects should be considered in modeling organic solar cells.

  2. Look up: Human adults use vertical height cues in reorientation.

    PubMed

    Du, Yu; Spetch, Marcia L; Mou, Weimin

    2016-11-01

    Numerous studies have shown that people and other animals readily use horizontal geometry (distance and directional information) to reorient, and these cues sometimes dominate over other cues when reorienting in navigable environments. Our study investigated whether horizontal cues (distance/angle) dominate over vertical cues (wall height) when they are in conflict. Adult participants learned two locations (opposite corners) in either a rectangular room (with distance information) or a rhombus room (with angle information). Both training rooms had 2 opposite high walls as height cues. On each trial, participants were disoriented and then asked to locate the correct corners. In testing, the rooms were modified to provide (a) distance or angle cues only, (b) height cues only, and (c) both height and horizontal cues in conflict. Participants located the correct corners successfully with horizontal (distance/angle) or height cues alone. On conflict tests, participants did not show preference for the horizontal information (distance/angle) over the height cues. The results are discussed in terms of the geometric module theory and the adaptive combination theory.

  3. Ergonomics in the operating room: protecting the surgeon.

    PubMed

    Rosenblatt, Peter L; McKinney, Jessica; Adams, Sonia R

    2013-01-01

    To review elements of an ergonomic operating room environment and describe common ergonomic errors in surgeon posture during laparoscopic and robotic surgery. Descriptive video based on clinical experience and a review of the literature (Canadian Task Force classification III). Community teaching hospital affiliated with a major teaching hospital. Gynecologic surgeons. Demonstration of surgical ergonomic principles and common errors in surgical ergonomics by a physical therapist and surgeon. The physical nature of surgery necessitates awareness of ergonomic principles. The literature has identified ergonomic awareness to be grossly lacking among practicing surgeons, and video has not been documented as a teaching tool for this population. Taking this into account, we created a video that demonstrates proper positioning of monitors and equipment, and incorrect and correct ergonomic positions during surgery. Also presented are 3 common ergonomic errors in surgeon posture: forward head position, improper shoulder elevation, and pelvic girdle asymmetry. Postural reset and motion strategies are demonstrated to help the surgeon learn techniques to counterbalance the sustained and awkward positions common during surgery that lead to muscle fatigue, pain, and degenerative changes. Correct ergonomics is a learned and practiced behavior. We believe that video is a useful way to facilitate improvement in ergonomic behaviors. We suggest that consideration of operating room setup, proper posture, and practice of postural resets are necessary components for a longer, healthier, and pain-free surgical career. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  4. Effects of Growth Conditions on the Measured Electrical Properties of Monolayer Molybdenum Disulfide

    DTIC Science & Technology

    2017-02-01

    rpm (thickness around 300 nm) and then baked on a hotplate at 185 °C for 2 min. The PMMA was exposed using a proximity effect correction with a base...and then soft baked at 50 °C in air for 30 min. After air-drying in a fume hood for an additional 3 h at room temperature, the PMMA was scraped from

  5. Atomistic structures of nano-engineered SiC and radiation-induced amorphization resistance

    NASA Astrophysics Data System (ADS)

    Imada, Kenta; Ishimaru, Manabu; Sato, Kazuhisa; Xue, Haizhou; Zhang, Yanwen; Shannon, Steven; Weber, William J.

    2015-10-01

    Nano-engineered 3C-SiC thin films, which possess columnar structures with high-density stacking faults and twins, were irradiated with 2 MeV Si ions at cryogenic and room temperatures. From cross-sectional transmission electron microscopy observations in combination with Monte Carlo simulations based on the Stopping and Range of Ions in Matter code, it was found that their amorphization resistance is six times greater than bulk crystalline SiC at room temperature. High-angle bright-field images taken by spherical aberration corrected scanning transmission electron microscopy revealed that the distortion of atomic configurations is localized near the stacking faults. The resultant strain field probably contributes to the enhancement of radiation tolerance of this material.

  6. Absorption measurements of the second overtone band of NO in ambient and combustion gases with a 1.8-mum room-temperature diode laser.

    PubMed

    Sonnenfroh, D M; Allen, M G

    1997-10-20

    We describe the development of a room-temperature diode sensor for in situ monitoring of combustion-generated NO. The sensor is based on a near-IR diode laser operating near 1.8 mum, which probes isolated transitions in the second overtone (3, 0) absorption band of NO. Based on absorption cell data, the sensitivity for ambient atmospheric pressure conditions is of the order of 30 parts in 10(6) by volume for a meter path (ppmv-m), assuming a minimum measurable absorbance of 10(-5). Initial H(2) -air flame measurements are complicated by strong water vapor absorption features that constrain the available gain and dynamic range of the present detection system. Preliminary results suggest that detection limits in this environment of the order of 140 ppmv-m could be achieved with optimum baseline correction.

  7. Absorption measurements of the second overtone band of NO in ambient and combustion gases with a 1.8- m room-temperature diode laser

    NASA Astrophysics Data System (ADS)

    Sonnenfroh, David M.; Allen, Mark G.

    1997-10-01

    We describe the development of a room-temperature diode sensor for in situ monitoring of combustion-generated NO. The sensor is based on a near-IR diode laser operating near 1.8 m, which probes isolated transitions in the second overtone (3,0) absorption band of NO. Based on absorption cell data, the sensitivity for ambient atmospheric pressure conditions is of the order of 30 parts in 10 6 by volume for a meter path (ppmv m), assuming a minimum measurable absorbance of 10 5 . Initial H 2 air flame measurements are complicated by strong water vapor absorption features that constrain the available gain and dynamic range of the present detection system. Preliminary results suggest that detection limits in this environment of the order of 140 ppmv m could be achieved with optimum baseline correction.

  8. Effect of Air Pollution on Exacerbations of Bronchiectasis in Badalona, Spain, 2008-2016.

    PubMed

    Garcia-Olivé, Ignasi; Stojanovic, Zoran; Radua, Joaquim; Rodriguez-Pons, Laura; Martinez-Rivera, Carlos; Ruiz Manzano, Juan

    2018-05-17

    Air pollution has been widely associated with respiratory diseases. Nevertheless, the association between air pollution and exacerbations of bronchiectasis has been less studied. To analyze the effect of air pollution on exacerbations of bronchiectasis. This was a retrospective observational study conducted in Badalona. The number of daily hospital admissions and emergency room visits related to exacerbation of bronchiectasis (ICD-9 code 494.1) between 2008 and 2016 was obtained. We used simple Poisson regressions to test the effects of daily mean temperature, SO2, NO2, CO, and PM10 levels on bronchiectasis-related emergencies and hospitalizations on the same day and 1-4 days after. All p values were corrected for multiple comparisons. SO2 was significantly associated with an increase in the number of hospitalizations (lags 0, 1, 2, and 3). None of these associations remained significant after correcting for multiple comparisons. The number of emergency room visits was associated with higher levels of SO2 (lags 0-4). After correcting for multiple comparisons, the association between emergency room visits and SO2 levels was statistically significant for lag 0 (p = 0.043), lag 1 (p = 0.018), and lag 3 (p = 0.050). The number of emergency room visits for exacerbation of bronchiectasis is associated with higher levels of SO2. © 2018 S. Karger AG, Basel.

  9. 76 FR 73687 - Curtis-Straus LLC; Application for Renewal of Recognition; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-29

    ... DEPARTMENT OF LABOR Occupational Safety and Health Administration [Docket No. OSHA-2009-0026... Health Administration (OSHA), Labor. ACTION: Notice; correction. SUMMARY: The Occupational Safety and..., Room N-2625, Occupational Safety and Health Administration, U.S. Department of Labor, at the address...

  10. 75 FR 39921 - Federal Advisory Committee; Defense Business Board (DBB); Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-13

    ... contact Ms. Debora Duffy, Defense Business Board, 1155 Defense Pentagon, Room 5B-1088A, Washington, DC 20301-1155, [email protected] , (703) 697- 2168. The Board's Designated Federal Officer (DFO) is Ms. Phyllis Ferguson, Defense Business Board, 1155 Defense Pentagon, Room 5B-1088A, Washington, DC 20301-1155...

  11. Whole body counter calibration using Monte Carlo modeling with an array of phantom sizes based on national anthropometric reference data

    NASA Astrophysics Data System (ADS)

    Shypailo, R. J.; Ellis, K. J.

    2011-05-01

    During construction of the whole body counter (WBC) at the Children's Nutrition Research Center (CNRC), efficiency calibration was needed to translate acquired counts of 40K to actual grams of potassium for measurement of total body potassium (TBK) in a diverse subject population. The MCNP Monte Carlo n-particle simulation program was used to describe the WBC (54 detectors plus shielding), test individual detector counting response, and create a series of virtual anthropomorphic phantoms based on national reference anthropometric data. Each phantom included an outer layer of adipose tissue and an inner core of lean tissue. Phantoms were designed for both genders representing ages 3.5 to 18.5 years with body sizes from the 5th to the 95th percentile based on body weight. In addition, a spherical surface source surrounding the WBC was modeled in order to measure the effects of subject mass on room background interference. Individual detector measurements showed good agreement with the MCNP model. The background source model came close to agreement with empirical measurements, but showed a trend deviating from unity with increasing subject size. Results from the MCNP simulation of the CNRC WBC agreed well with empirical measurements using BOMAB phantoms. Individual detector efficiency corrections were used to improve the accuracy of the model. Nonlinear multiple regression efficiency calibration equations were derived for each gender. Room background correction is critical in improving the accuracy of the WBC calibration.

  12. Atomistic structures of nano-engineered SiC and radiation-induced amorphization resistance

    DOE PAGES

    Imada, Kenta; Ishimaru, Manabu; Sato, Kazuhisa; ...

    2015-06-18

    In this paper, nano-engineered 3C–SiC thin films, which possess columnar structures with high-density stacking faults and twins, were irradiated with 2 MeV Si ions at cryogenic and room temperatures. From cross-sectional transmission electron microscopy observations in combination with Monte Carlo simulations based on the Stopping and Range of Ions in Matter code, it was found that their amorphization resistance is six times greater than bulk crystalline SiC at room temperature. High-angle bright-field images taken by spherical aberration corrected scanning transmission electron microscopy revealed that the distortion of atomic configurations is localized near the stacking faults. Finally, the resultant strain fieldmore » probably contributes to the enhancement of radiation tolerance of this material.« less

  13. 78 FR 46333 - Product Cancellation Order for Certain Pesticide Registrations; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-31

    ... 20460-0001. The Public Reading Room is open from 8:30 a.m. to 4:30 p.m., Monday through Friday, excluding legal holidays. The telephone number for the Public Reading Room is (202) 566-1744, and the telephone number for the OPP Docket is (703) 305-5805. Please review the visitor instructions and additional...

  14. 78 FR 72879 - Product Cancellation Order for Certain Pesticide Registrations; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-04

    ..., DC 20460-0001. The Public Reading Room is open from 8:30 a.m. to 4:30 p.m., Monday through Friday, excluding legal holidays. The telephone number for the Public Reading Room is (202) 566-1744, and the telephone number for the OPP Docket is (703) 305- 5805. Please review the visitor instructions and...

  15. Persons with Multiple Disabilities Use Orientation Technology to Find Room Entrances during Indoor Traveling

    ERIC Educational Resources Information Center

    Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Alberti, Gloria; Scigliuzzo, Francesca; Signorino, Mario; Oliva, Doretta; Smaldone, Angela; La Martire, Maria L.

    2010-01-01

    These two studies assessed adapted orientation technology for promoting correct direction and room identification during indoor traveling by persons with multiple (e.g., sensory, motor and intellectual/adaptive) disabilities. In Study I, two adults were included who had severe visual impairment or total blindness and deafness and used a wheelchair…

  16. Ifcwall Reconstruction from Unstructured Point Clouds

    NASA Astrophysics Data System (ADS)

    Bassier, M.; Klein, R.; Van Genechten, B.; Vergauwen, M.

    2018-05-01

    The automated reconstruction of Building Information Modeling (BIM) objects from point cloud data is still ongoing research. A key aspect is the creation of accurate wall geometry as it forms the basis for further reconstruction of objects in a BIM. After segmenting and classifying the initial point cloud, the labelled segments are processed and the wall topology is reconstructed. However, the preocedure is challenging due to noise, occlusions and the complexity of the input data.In this work, a method is presented to automatically reconstruct consistent wall geometry from point clouds. More specifically, the use of room information is proposed to aid the wall topology creation. First, a set of partial walls is constructed based on classified planar primitives. Next, the rooms are identified using the retrieved wall information along with the floors and ceilings. The wall topology is computed by the intersection of the partial walls conditioned on the room information. The final wall geometry is defined by creating IfcWallStandardCase objects conform the IFC4 standard. The result is a set of walls according to the as-built conditions of a building. The experiments prove that the used method is a reliable framework for wall reconstruction from unstructured point cloud data. Also, the implementation of room information reduces the rate of false positives for the wall topology. Given the walls, ceilings and floors, 94% of the rooms is correctly identified. A key advantage of the proposed method is that it deals with complex rooms and is not bound to single storeys.

  17. [Electrocardiographic diagnosis: when QRS is wide.

    PubMed

    Conti, Matilde; Bregani, Enrico Rino

    2018-04-01

    Differential diagnosis of one or more wide QRS complexes on an electrocardiogram under emergency conditions takes into account three main sets of clinical conditions: ventricular pre-excitation, aberrant conduction and ventricular beats and it is based on the morphological analysis of the ECG and patient's anamnestic data. Several criteria can facilitate the differential diagnosis and if properly used and integrated with clinic data they can achieve good diagnostic accuracy in most cases. In this review several criteria based on evidence and literature are presented, paying attention in recognizing some morphologic pathways that can be used in emergency room and allow a correct ECG assessment.

  18. Evidence-based treatment practices for drug-involved adults in the criminal justice system.

    PubMed

    Friedmann, Peter D; Taxman, Faye S; Henderson, Craig E

    2007-04-01

    The aim of this study was to estimate the extent and organizational correlates of evidence-based practices (EBPs) in correctional facilities and community-based substance abuse treatment programs that manage drug-involved adult offenders. Correctional administrators and treatment program directors affiliated with a national sample of 384 criminal justice and community-based programs providing substance abuse treatment to adult offenders in the United States were surveyed in 2004. Correctional administrators reported the availability of up to 13 specified EBPs, and treatment directors up to 15. The sum total of EBPs indicates their extent. Linear models regress the extent of EBPs on variables measuring structure and leadership, culture and climate, administrator attitudes, and network connectedness of the organization. Most programs offer fewer than 60% of the specified EBPs to drug-involved offenders. In multiple regression models, offender treatment programs that provided more EBPs were community based, accredited, and network connected, with a performance-oriented, nonpunitive culture, more training resources, and leadership with a background in human services, a high regard for the value of substance abuse treatment, and an understanding of EBPs. The use of EBPs among facility- and community-based programs that serve drug-involved adult offenders has room for improvement. Initiatives to disseminate EBPs might target these institutional and environmental domains, but further research is needed to determine whether such organization interventions can promote the uptake of EBPs.

  19. EVIDENCE-BASED TREATMENT PRACTICES FOR DRUG-INVOLVED ADULTS IN THE CRIMINAL JUSTICE SYSTEM

    PubMed Central

    Friedmann, Peter D.; Taxman, Faye S.; Henderson, Craig E.

    2007-01-01

    OBJECTIVE To estimate the extent and organizational correlates of evidence-based practices (EBPs) in correctional facilities and community-based substance abuse treatment programs that manage drug-involved adult offenders. METHODS Correctional administrators and treatment program directors affiliated with a national sample of 384 criminal justice and community-based programs providing substance abuse treatment to adult offenders in the United States were surveyed in 2004. Correctional administrators reported the availability of up to 13 specified EBPs and treatment directors up to 15. The sum total of EBPs indicates their extent. Linear models regress the extent of EBPs on variables measuring structure and leadership, culture and climate, administrator attitudes and network connectedness of the organization. RESULTS Most programs offer fewer than 60% of the specified EBPs to drug-involved offenders. In multiple regression models, offender treatment programs that provided more EBPs were community-based, accredited, and network-connected; with a performance-oriented, non-punitive culture, more training resources; and leadership with a background in human services, a high regard for the value of substance abuse treatment and an understanding of EBPs. CONCLUSIONS The use of EBPs among facility- and community-based programs that serve drug-involved adult offenders has room for improvement. Initiatives to disseminate EBPs might target these institutional and environmental domains, but further research is needed to determine whether such organization interventions can promote the uptake of EBPs. PMID:17383551

  20. 77 FR 51579 - Meetings of Humanities Panel; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-24

    ... Voyatzis, Committee Management Officer, at (202) 606-8322. Correction In the Federal Register of August 14... replace with: 9. Date: September 24, 2012. Time: 8:30 a.m. to 5:00 p.m. Room: 315. This meeting will discuss applications for the Bridging Cultures at Community Colleges: Request for Proposals for a...

  1. View of Mission Control Center during the Apollo 13 oxygen cell failure

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Mrs. Mary Haise receives an explanation of the revised flight plan of the Apollo 13 mission from Astronaut Gerald P. Carr in the Viewing Room of Mission Control Center, bldg 30, Manned Spacecraft Center (MSC). Her husband, Astronaut Fred W. Haise Jr., was joining the fellow crew members in making corrections in their spacecraft following discovery of an oxygen cell failure several hours earlier (34900); Dr. Charles A. Berry, Director of Medical Research and Operations Directorate at MSC, converses with Mrs. Marilyn Lovell in the Viewing Room of Mission Control Center. Mrs. Lovell's husband, Astronaut James A. Lovell Jr., was busily making corrections inside the spacecraft following discovery of an oxygen cell failure several hours earlier (34901).

  2. Predicting the stability of nanodevices

    NASA Astrophysics Data System (ADS)

    Lin, Z. Z.; Yu, W. F.; Wang, Y.; Ning, X. J.

    2011-05-01

    A simple model based on the statistics of single atoms is developed to predict the stability or lifetime of nanodevices without empirical parameters. Under certain conditions, the model produces the Arrhenius law and the Meyer-Neldel compensation rule. Compared with the classical molecular-dynamics simulations for predicting the stability of monatomic carbon chain at high temperature, the model is proved to be much more accurate than the transition state theory. Based on the ab initio calculation of the static potential, the model can give out a corrected lifetime of monatomic carbon and gold chains at higher temperature, and predict that the monatomic chains are very stable at room temperature.

  3. Project Report: Reducing Color Rivalry in Imagery for Conjugated Multiple Bandpass Filter Based Stereo Endoscopy

    NASA Technical Reports Server (NTRS)

    Ream, Allen

    2011-01-01

    A pair of conjugated multiple bandpass filters (CMBF) can be used to create spatially separated pupils in a traditional lens and imaging sensor system allowing for the passive capture of stereo video. This method is especially useful for surgical endoscopy where smaller cameras are needed to provide ample room for manipulating tools while also granting improved visualizations of scene depth. The significant issue in this process is that, due to the complimentary nature of the filters, the colors seen through each filter do not match each other, and also differ from colors as seen under a white illumination source. A color correction model was implemented that included optimized filter selection, such that the degree of necessary post-processing correction was minimized, and a chromatic adaptation transformation that attempted to fix the imaged colors tristimulus indices based on the principle of color constancy. Due to fabrication constraints, only dual bandpass filters were feasible. The theoretical average color error after correction between these filters was still above the fusion limit meaning that rivalry conditions are possible during viewing. This error can be minimized further by designing the filters for a subset of colors corresponding to specific working environments.

  4. Safety, reliability, and validity of a physiologic definition of bronchopulmonary dysplasia.

    PubMed

    Walsh, Michele C; Wilson-Costello, Deanna; Zadell, Arlene; Newman, Nancy; Fanaroff, Avroy

    2003-09-01

    Bronchopulmonary dysplasia (BPD) is the focus of many intervention trials, yet the outcome measure when based solely on oxygen administration may be confounded by differing criteria for oxygen administration between physicians. Thus, we wished to define BPD by a standardized oxygen saturation monitoring at 36 weeks corrected age, and compare this physiologic definition with the standard clinical definition of BPD based solely on oxygen administration. A total of 199 consecutive very low birthweight infants (VLBW, 501 to 1500 g birthweight) were assessed prospectively at 36+/-1 weeks corrected age. Neonates on positive pressure support or receiving >30% supplemental oxygen were assigned the outcome BPD. Those receiving < or =30% oxygen underwent a stepwise 2% reduction in supplemental oxygen to room air while under continuous observation and oxygen saturation monitoring. Outcomes of the test were "no BPD" (saturations > or =88% for 60 minutes) or "BPD" (saturation < 88%). At the conclusion of the test, all infants were returned to their baseline oxygen. Safety (apnea, bradycardia, increased oxygen use), inter-rater reliability, test-retest reliability, and validity of the physiologic definition vs the clinical definition were assessed. A total of 199 VLBW were assessed, of whom 45 (36%) were diagnosed with BPD by the clinical definition of oxygen use at 36 weeks corrected age. The physiologic definition identified 15 infants treated with oxygen who successfully passed the saturation monitoring test in room air. The physiologic definition diagnosed BPD in 30 (24%) of the cohort. All infants were safely studied. The test was highly reliable (inter-rater reliability, kappa=1.0; test-retest reliability, kappa=0.83) and highly correlated with discharge home in oxygen, length of hospital stay, and hospital readmissions in the first year of life. The physiologic definition of BPD is safe, feasible, reliable, and valid and improves the precision of the diagnosis of BPD. This may be of benefit in future multicenter clinical trials.

  5. How a smiley protects health: A pilot intervention to improve hand hygiene in hospitals by activating injunctive norms through emoticons

    PubMed Central

    Tsivrikos, Dimitrios; Dollinger, Daniel; Lermer, Eva

    2018-01-01

    Hand hygiene practice in hospitals is unfortunately still widely insufficient, even though it is known that transmitting pathogens via hands is the leading cause of healthcare-associated infections. Previous research has shown that improving knowledge, providing feedback on past behaviour and targeting social norms are promising approaches to improve hand hygiene practices. The present field experiment was designed to direct people on when to perform hand hygiene and prevent forgetfulness. This intervention is the first to examine the effect of inducing injunctive social norms via an emoticon-based feedback system on hand hygiene behaviour. Electronic monitoring and feedback devices were installed in hospital patient rooms on top of hand-rub dispensers, next to the doorway, for a period of 17 weeks. In the emoticon condition, screens at the devices activated whenever a person entered or exited the room. Before using the alcohol-based hand-rub dispenser, a frowny face was displayed, indicating that hand hygiene should be performed. If the dispenser was subsequently used, this picture changed to a smiley face to positively reinforce the correct behaviour. Hand hygiene behaviour in the emoticon rooms significantly outperformed the behaviour in three other tested conditions. The strong effect in this field experiment indicates that activating injunctive norms may be a promising approach to improve hand hygiene behaviour. Theoretical and practical implications of these findings are discussed. PMID:29782516

  6. Teaching Data Science to Post Graduate Students: A Preliminary Study Using a "F-L-I-P" Class Room Approach

    ERIC Educational Resources Information Center

    Eybers, Sunet; Hattingh, Mariè

    2016-01-01

    Data is everywhere. As a result the need for data scientists with the correct skill set to analyze and interpret the data has escalated. Not surprisingly, data scientists are currently one of the most wanted professions. Tertiary institutions are faced with the challenge of producing students with the correct blend of theoretical knowledge and…

  7. Application of TlBr to nuclear medicine imaging

    NASA Astrophysics Data System (ADS)

    Cirignano, Leonard; Kim, Hadong; Kargar, Alireza; Churilov, Alexei V.; Ciampi, Guido; Higgins, William; Kim, Suyoung; Barber, Bradford; Haston, Kyle; Shah, Kanai

    2012-10-01

    Thallium bromide (TlBr) has been under development for room temperature gamma ray spectroscopy due to high density, high Z and wide bandgap of the material. Furthermore, its low melting point (460 °C), cubic crystal structure and congruent melting with no solid-solid phase transitions between the melting point and room temperature, TlBr can be grown by relatively simple melt based methods. As a result of improvements in material processing and detector fabrication over the last several years, TlBr with electron mobility-lifetime products (μeτe) in the mid 10-3 cm2/V range has been obtained. In this paper we are going to report on our unipolar charging TlBr results for the application as a small animal imaging. For SPECT application, about 5 mm thick pixellated detectors were fabricated and tested. About 1 % FWHM at 662 keV energy resolution was estimated at room temperature. By applying the depth correction technique, less than 1 % energy resolution was estimated. We are going to report the results from orthogonal strip TlBr detector for PET application. In this paper we also present our latest detector highlights and recent progress made in long term stability of TlBr detectors at or near room temperature. This work is being supported by the Domestic Nuclear Detection Office (DNDO) and the Department of Energy (DOE).

  8. Refinement of motion correction strategies for lower-cost CT for under-resourced regions of the world

    NASA Astrophysics Data System (ADS)

    Wells, Jered R.; Segars, W. Paul; Kigongo, Christopher J. N.; Dobbins, James T., III

    2011-03-01

    This paper describes a recently developed post-acquisition motion correction strategy for application to lower-cost computed tomography (LCCT) for under-resourced regions of the world. Increased awareness regarding global health and its challenges has encouraged the development of more affordable healthcare options for underserved people worldwide. In regions such as sub-Saharan Africa, intermediate level medical facilities may serve millions with inadequate or antiquated equipment due to financial limitations. In response, the authors have proposed a LCCT design which utilizes a standard chest x-ray examination room with a digital flat panel detector (FPD). The patient rotates on a motorized stage between the fixed cone-beam source and FPD, and images are reconstructed using a Feldkamp algorithm for cone-beam scanning. One of the most important proofs-of-concept in determining the feasibility of this system is the successful correction of undesirable motion. A 3D motion correction algorithm was developed in order to correct for potential patient motion, stage instabilities and detector misalignments which can all lead to motion artifacts in reconstructed images. Motion will be monitored by the radiographic position of fiducial markers to correct for rigid body motion in three dimensions. Based on simulation studies, projection images corrupted by motion were re-registered with average errors of 0.080 mm, 0.32 mm and 0.050 mm in the horizontal, vertical and depth dimensions, respectively. The overall absence of motion artifacts in motion-corrected reconstructions indicates that reasonable amounts of motion may be corrected using this novel technique without significant loss of image quality.

  9. 77 FR 47859 - Proposed Flood Hazard Determinations; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-10

    ... Boulevard, Deerfield Beach, FL 33442. City of Fort Lauderdale City Hall, 100 North Andrews Avenue, Fort..., 115 South Andrews Avenue, Room 409, Fort Lauderdale, FL 33301. Village of Lazy Lake Village Hall, 2250...

  10. Thermally Activated Deformation Behavior of ufg-Au: Environmental Issues During Long-Term and High-Temperature Nanoindentation Testing

    NASA Astrophysics Data System (ADS)

    Maier, Verena; Leitner, Alexander; Pippan, Reinhard; Kiener, Daniel

    2015-12-01

    For testing time-dependent material properties by nanoindentation, in particular for long-term creep or relaxation experiments, thermal drift influences on the displacement signal are of prime concern. To address this at room and elevated temperatures, we tested fused quartz at various contact depths at room temperature and ultra-fine grained (ufg) Au at various temperatures. We found that the raw data for fused quartz are strongly affected by thermal drift, but corrected by use of dynamic stiffness measurements all the datasets collapse. The situation for the ufg Au shows again that the data are only useful with drift correction, but with this applied it turns out that there is a significant change of elastic and plastic properties when exceeding 200°C, which is also reflected by an increasing strain rate sensitivity.

  11. 75 FR 72739 - Compliance Testing Procedures: Correction Factor for Room Air Conditioners

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-26

    ... industry practices or consensus body testing standards which have been superseded by standards which are... accurate. With these facts in mind, DOE compliance enforcement forbearance, or an industry-wide waiver or...

  12. [Contribution of the Duke's classification in the emergency department in the early management of infective endocarditis].

    PubMed

    Hautain, C; Delleuze, P; Godefroid, C; Vranckx, M

    2015-01-01

    The diagnosis of infective endocarditis is based on multiple clinical signs than on a single positive test result. The contribution of echocardiography is an indispensable asset to avoid misdiagnosis or delayed correct diagnosis. A 24-year old woman is admitted to the emergency room. She has a poor general condition, pyrexia and necrotic lesions on the body. After examination, the diagnosis of multiple organ failure and severe sepsis from infective endocarditis from intravenous injections of cocaine is made and the patient is transferred to ICU. She is treated with vancomycin for 4 weeks and gentamicin for 8 days. Her clinical improvement allows her to be transferred to a hospital unit at day 6. She goes home after 28 days of hospitalization. Several sets of criteria for the diagnosis of infective endocarditis are described. The most commonly accepted are revised Duke's criteria that take into account echocardiography. This article aims, through a clinical case, to describe this classification too little used in the emergency room.

  13. Implementation of Fuzzy Decision to Control Patient Room Facilities using Eye Blink

    NASA Astrophysics Data System (ADS)

    Zaeni, Ilham A. E.; Wibawa, Aji P.; Aripriharta; Sendari, Siti

    2018-04-01

    This study proposed the implementation of Fuzzy decision to control patient’s room facilities. In this study, four icons were sequentially displayed on the computer screen. The icons representing four option that can be selected by the patient is including switch the light on/off, switch the fan on/off, moving the bed’s backrest downward, and moving the bed’s backrest upward. The eye blink was extracted from subject’s electroencephalograph (EEG) signals which acquired from the FP1 region. The attention was also extracted from subject’s EEG signals to ensure that subject concentrate to the task. The eye blink and attention level were used for Fuzzy decision inputs, while the output is a decision that states the selection is valid or not. The selected option is the command that appears on the screen when the selection is valid. In this study, subjects were asked to choose each command several times and the accuracy was computed based on the number of correct selection.

  14. 76 FR 19913 - Compliance Testing Procedures: Correction Factor for Room Air Conditioners

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-11

    ... covered under ASHRAE Standard 37, generally do not have this feature and operate primarily with dry... performance. It is the air mass flow rate that transfers heat between cooler coils or condensers and...

  15. What clues are available for differential diagnosis of headaches in emergency settings?

    PubMed

    Mert, Ertan; Ozge, Aynur; Taşdelen, Bahar; Yilmaz, Arda; Bilgin, Nursel G

    2008-04-01

    The correct diagnosis of headache disorders in an emergency room is important for developing early management strategies and determining optimal emergency room activities. This prospective clinical based study was performed in order to determine demographic and clinical clues for differential diagnosis of primary and secondary headache disorders and also to obtain a classification plot for the emergency room practitioners. This study included 174 patients older than 15 years of age presenting in the emergency room with a chief complaint of headache. Definite headache diagnoses were made according to ICHD-II criteria. Classification and regression tree was used as new method for the statistical analysis of the differential diagnostic process. Our 174 patients with headache were diagnosed as basically primary (72.9%) and secondary (27.1%) headaches. Univariate analysis with cross tabs showed three important results. First, unilateral pain location caused 1.431-fold increase in the primary headache risk (p = 0.006). Second, having any triggers caused 1.440-fold increase in the primary headache risk (p = 0.001). Third, having associated co-morbid medical disorders caused 4.643-fold increase in the secondary headache risk (p < 0.001). It was concluded that the presence of comorbidity, the patient's age, the existence of trigger and relaxing factors, the pain in other body parts that accompanies headache and the quality of pain in terms of location and duration were all important clues for physicians in making an accurate differentiation between primary and secondary headaches.

  16. The influence of room temperature on Mg isotope measurements by MC-ICP-MS.

    PubMed

    Zhang, Xing-Chao; Zhang, An-Yu; Zhang, Zhao-Feng; Huang, Fang; Yu, Hui-Min

    2018-03-24

    We observed that the accuracy and precision of magnesium (Mg) isotope analyses could be affected if the room temperature oscillated during measurements. To achieve high quality Mg isotopic data, it is critical to evaluate how the unstable room temperature affects Mg isotope measurements by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). We measured the Mg isotopes for the reference material DSM-3 using MC-ICP-MS under oscillating room temperatures in spring. For a comparison, we also measured the Mg isotopes under stable room temperatures, which was achieved by the installation of an improved temperature control system in the laboratory. The δ 26 Mg values measured under oscillating room temperatures have a larger deviation (δ 26 Mg from -0.09 to 0.08‰, with average δ 26 Mg = 0.00 ± 0.08 ‰) than those measured under a stable room temperature (δ 26 Mg from -0.03 to 0.03‰, with average δ 26 Mg = 0.00 ± 0.02 ‰) using the same MC-ICP-MS system. The room temperature variation can influence the stability of MC-ICP-MS. Therefore, it is critical to keep the room temperature stable to acquire high precise and accurate isotopic data when using MC-ICP-MS, especially when using the sample-standard bracketing (SSB) correction method. This article is protected by copyright. All rights reserved.

  17. Age determination of bottled Chinese rice wine by VIS-NIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Yu, Haiyan; Lin, Tao; Ying, Yibin; Pan, Xingxiang

    2006-10-01

    The feasibility of non-invasive visible and near infrared (VIS-NIR) spectroscopy for determining wine age (1, 2, 3, 4, and 5 years) of Chinese rice wine was investigated. Samples of Chinese rice wine were analyzed in 600 mL square brown glass bottles with side length of approximately 64 mm at room temperature. VIS-NIR spectra of 100 bottled Chinese rice wine samples were collected in transmission mode in the wavelength range of 350-1200 nm by a fiber spectrometer system. Discriminant models were developed based on discriminant analysis (DA) together with raw, first and second derivative spectra. The concentration of alcoholic degree, total acid, and °Brix was determined to validate the NIR results. The calibration result for raw spectra was better than that for first and second derivative spectra. The percentage of samples correctly classified for raw spectra was 98%. For 1-, 2-, and 3-year-old sample groups, the sample were all correctly classified, and for 4- and 5-year-old sample groups, the percentage of samples correctly classified was 92.9%, respectively. In validation analysis, the percentage of samples correctly classified was 100%. The results demonstrated that VIS-NIR spectroscopic technique could be used as a non-invasive, rapid and reliable method for predicting wine age of bottled Chinese rice wine.

  18. Microclimate monitoring of Ariadne's house (Pompeii, Italy) for preventive conservation of fresco paintings.

    PubMed

    Merello, Paloma; García-Diego, Fernando-Juan; Zarzo, Manuel

    2012-11-28

    Ariadne's house, located at the city center of ancient Pompeii, is of great archaeological value due to the fresco paintings decorating several rooms. In order to assess the risks for long-term conservation affecting the valuable mural paintings, 26 temperature data-loggers and 26 relative humidity data-loggers were located in four rooms of the house for the monitoring of ambient conditions. Data recorded during 372 days were analyzed by means of graphical descriptive methods and analysis of variance (ANOVA). Results revealed an effect of the roof type and number of walls of the room. Excessive temperatures were observed during the summer in rooms covered with transparent roofs, and corrective actions were taken. Moreover, higher humidity values were recorded by sensors on the floor level. The present work provides guidelines about the type, number, calibration and position of thermohygrometric sensors recommended for the microclimate monitoring of mural paintings in outdoor or semi-confined environments.

  19. Master Console System Monitoring and Control Development

    NASA Technical Reports Server (NTRS)

    Brooks, Russell A.

    2013-01-01

    The Master Console internship during the spring of 2013 involved the development of firing room displays at the John F. Kennedy Space Center (KSC). This position was with the Master Console Product Group (MCPG) on the Launch Control System (LCS) project. This project is responsible for the System Monitoring and Control (SMC) and Record and Retrieval (R&R) of launch operations data. The Master Console is responsible for: loading the correct software into each of the remaining consoles in the firing room, connecting the proper data paths to and from the launch vehicle and all ground support equipment, and initializing the entire firing room system to begin processing. During my internship, I developed a system health and status display for use by Master Console Operators (MCO) to monitor and verify the integrity of the servers, gateways, network switches, and firewalls used in the firing room.

  20. 77 FR 13015 - Fresh Fruit and Vegetable Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-05

    ... information is corrected to read ``Julie Brewer, Chief, Policy and Program Development Branch, Child Nutrition Division, Food and Nutrition Service, USDA, 3101 Park Center Drive, Room 634, Alexandria, Virginia 22302... 5, 2012 / Proposed Rules#0;#0; [[Page 13015

  1. A binary-decision-diagram-based two-bit arithmetic logic unit on a GaAs-based regular nanowire network with hexagonal topology.

    PubMed

    Zhao, Hong-Quan; Kasai, Seiya; Shiratori, Yuta; Hashizume, Tamotsu

    2009-06-17

    A two-bit arithmetic logic unit (ALU) was successfully fabricated on a GaAs-based regular nanowire network with hexagonal topology. This fundamental building block of central processing units can be implemented on a regular nanowire network structure with simple circuit architecture based on graphical representation of logic functions using a binary decision diagram and topology control of the graph. The four-instruction ALU was designed by integrating subgraphs representing each instruction, and the circuitry was implemented by transferring the logical graph structure to a GaAs-based nanowire network formed by electron beam lithography and wet chemical etching. A path switching function was implemented in nodes by Schottky wrap gate control of nanowires. The fabricated circuit integrating 32 node devices exhibits the correct output waveforms at room temperature allowing for threshold voltage variation.

  2. Deep eutectic solvents based on N-methylacetamide and a lithium salt as suitable electrolytes for lithium-ion batteries.

    PubMed

    Boisset, Aurélien; Menne, Sebastian; Jacquemin, Johan; Balducci, Andrea; Anouti, Mérièm

    2013-12-14

    In this work, we present a study on the physical and electrochemical properties of three new Deep Eutectic Solvents (DESs) based on N-methylacetamide (MAc) and a lithium salt (LiX, with X = bis[(trifluoromethyl)sulfonyl]imide, TFSI; hexafluorophosphate, PF6; or nitrate, NO3). Based on DSC measurements, it appears that these systems are liquid at room temperature for a lithium salt mole fraction ranging from 0.10 to 0.35. The temperature dependences of the ionic conductivity and the viscosity of these DESs are correctly described by using the Vogel-Tammann-Fulcher (VTF) type fitting equation, due to the strong interactions between Li(+), X(-) and MAc in solution. Furthermore, these electrolytes possess quite large electrochemical stability windows up to 4.7-5 V on Pt, and demonstrate also a passivating behavior toward the aluminum collector at room temperature. Based on these interesting electrochemical properties, these selected DESs can be classified as potential and promising electrolytes for lithium-ion batteries (LIBs). For this purpose, a test cell was then constructed and tested at 25 °C, 60 °C and 80 °C by using each selected DES as an electrolyte and LiFePO4 (LFP) material as a cathode. The results show a good compatibility between each DES and LFP electrode material. A capacity of up to 160 mA h g(-1) with a good efficiency (99%) is observed in the DES based on the LiNO3 salt at 60 °C despite the presence of residual water in the electrolyte. Finally preliminary tests using a LFP/DES/LTO (lithium titanate) full cell at room temperature clearly show that LiTFSI-based DES can be successfully introduced into LIBs. Considering the beneficial properties, especially, the cost of these electrolytes, such introduction could represent an important contribution for the realization of safer and environmentally friendly LIBs.

  3. Mrs. Haise in viewing room overlooking FCR

    NASA Image and Video Library

    1970-04-14

    S70-34900 (14 April 1970) --- Mrs. Mary Haise receives an explanation of the revised flight plan of the Apollo 13 mission from astronaut Gerald P. Carr in the viewing room of the Mission Control Center (MCC), Building 30, at the Manned Spacecraft Center (MSC). Her husband, astronaut Fred W. Haise Jr., lunar module pilot for the Apollo 13 mission, was joining fellow crew members, astronauts James A. Lovell Jr., and John L. Swigert Jr. in making correction in their spacecraft following discovery of an oxygen cell failure several hours earlier.

  4. The effect of different brightness conditions on visually and memory guided saccades.

    PubMed

    Felßberg, Anna-Maria; Dombrowe, Isabel

    2018-01-01

    It is commonly assumed that saccades in the dark are slower than saccades in a lit room. Early studies that investigated this issue using electrooculography (EOG) often compared memory guided saccades in darkness to visually guided saccades in an illuminated room. However, later studies showed that memory guided saccades are generally slower than visually guided saccades. Research on this topic is further complicated by the fact that the different existing eyetracking methods do not necessarily lead to consistent measurements. In the present study, we independently manipulated task (memory guided/visually guided) and screen brightness (dark, medium and light) in an otherwise completely dark room, and measured the peak velocity and the duration of the participant's saccades using a popular pupil-cornea reflection (p-cr) eyetracker (Eyelink 1000). Based on a critical reading of the literature, including a recent study using cornea-reflection (cr) eye tracking, we did not expect any velocity or duration differences between the three brightness conditions. We found that memory guided saccades were generally slower than visually guided saccades. In both tasks, eye movements on a medium and light background were equally fast and had similar durations. However, saccades on the dark background were slower and had shorter durations, even after we corrected for the effect of pupil size changes. This means that this is most likely an artifact of current pupil-based eye tracking. We conclude that the common assumption that saccades in the dark are slower than in the light is probably not true, however pupil-based eyetrackers tend to underestimate the peak velocity of saccades on very dark backgrounds, creating the impression that this might be the case. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Hospital cost analysis of neuromuscular scoliosis surgery.

    PubMed

    Diefenbach, Christopher; Ialenti, Marc N; Lonner, Baron S; Kamerlink, Jonathan R; Verma, Kushagra; Errico, Thomas J

    2013-01-01

    A retrospective review of 74 consecutive, surgical patients with neuromuscular scoliosis (NMS). This study evaluates the distribution of hospital and operating room costs incurred during surgical correction of NMS. Recent studies have demonstrated that surgical treatment improves both medical outcomes and the quality of life in patients with progressive NMS. Characterization of the costs incurred at the time of surgery and hospitalization will facilitate the identification of opportunities for cost reduction. Demographic data collected included gender, age, preoperative height, weight, and BMI. Major coronal curvatures and T5-T12 kyphosis were assessed from radiographs. Construct type and number of screws, hooks, and wires implanted were recorded. Surgical costs were calculated based on cost of surgical correction, hospital stay, and postoperative care. Mean age was 15.8 ± 7.3 years; 57% were male. Comorbidities included cerebral palsy (28%) and familial dysautonomia (14%). The mean preoperative major curve magnitude was 60°; minor curve magnitude was 33°. Posterior approach (76%) and pedicle screws (75%) were predominantly utilized. The average length of hospitalization was 8 days (range: 3 to 47). There were six major complications (8%). The total surgical cost was $50,096 ± $23,998. The highest individual cost was for implants ($13,916; 24% of total costs). The second highest was inpatient room and ICU costs ($12,483; 22%); bone grafts were the third ($6,398; 11%). Increased major and minor structural curve, increased total (A/P) levels fused, and increased length of hospital stay predicted an increase in total cost. Major contributors to cost in NMS surgery are implants, inpatient room and ICU costs, and bone grafts. Independent predictors of higher cost are the degree of major and minor structural curve, total number of A/P levels fused, and length of hospital stay. These conclusions provide insight into costs associated with care for a medically fragile and challenging patient population.

  6. Sulfonyl fluoride-based prosthetic compounds as potential 18F labelling agents.

    PubMed

    Inkster, James A H; Liu, Kate; Ait-Mohand, Samia; Schaffer, Paul; Guérin, Brigitte; Ruth, Thomas J; Storr, Tim

    2012-08-27

    Nucleophilic incorporation of [(18)F]F(-) under aqueous conditions holds several advantages in radiopharmaceutical development, especially with the advent of complex biological pharmacophores. Sulfonyl fluorides can be prepared in water at room temperature, yet they have not been assayed as a potential means to (18)F-labelled biomarkers for PET chemistry. We developed a general route to prepare bifunctional 4-formyl-, 3-formyl-, 4-maleimido- and 4-oxylalkynl-arylsulfonyl [(18)F]fluorides from their sulfonyl chloride analogues in 1:1 mixtures of acetonitrile, THF, or tBuOH and Cs[(18)F]F/Cs(2)CO(3(aq.)) in a reaction time of 15 min at room temperature. With the exception of 4-N-maleimide-benzenesulfonyl fluoride (3), pyridine could be used to simplify radiotracer purification by selectively degrading the precursor without significantly affecting observed yields. The addition of pyridine at the start of [(18)F]fluorination (1:1:0.8 tBuOH/Cs(2)CO(3(aq.))/pyridine) did not negatively affect yields of 3-formyl-2,4,6-trimethylbenzenesulfonyl [(18)F]fluoride (2) and dramatically improved the yields of 4-(prop-2-ynyloxy)benzenesulfonyl [(18)F]fluoride (4). The N-arylsulfonyl-4-dimethylaminopyridinium derivative of 4 (14) can be prepared and incorporates (18)F efficiently in solutions of 100 % aqueous Cs(2)CO(3) (10 mg mL(-1)). As proof-of-principle, [(18)F]2 was synthesised in a preparative fashion [88(±8) % decay corrected (n=6) from start-of-synthesis] and used to radioactively label an oxyamino-modified bombesin(6-14) analogue [35(±6) % decay corrected (n=4) from start-of-synthesis]. Total preparation time was 105-109 min from start-of-synthesis. Although the (18)F-peptide exhibited evidence of proteolytic defluorination and modification, our study is the first step in developing an aqueous, room temperature (18)F labelling strategy. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Ventriculoperitoneal Shunt Fracture Following Application of Halo-Gravity Traction: A Case Report.

    PubMed

    Blakeney, William G; D'Amato, Charles

    2015-09-01

    Ventriculoperitoneal (VP) shunt malfunctions are very common, and shunt fracture is one of the most common causes. Shunt fractures are often a result of calcification and tethering, which predispose the tubing to fracture when mechanical stresses are applied. This case report describes a case of shunt fracture following application of halo-gravity traction for correction of spinal deformity. Chart and imaging data for a single case were reviewed and reported in this retrospective case study. A 10-year-old female, being treated for syndromic scoliosis, underwent posterior surgical release and application of halo-gravity traction. Increasing weight of traction was applied over a period of 6 weeks, for gradual deformity correction. It was noted on the 6-week cervical spine radiograph that the VP shunt had fractured at the base of the neck. The patient was taken to the operating room and intraoperative findings confirmed shunt fracture. This was repaired without complications. This case, to our best knowledge, is the first reported occurrence of shunt fracture following application of halo-gravity traction. It demonstrates the importance of careful monitoring of patients with VP shunts, when they are undergoing traction for correction of spinal deformity. Level IV.

  8. KSC-90PC-0626

    NASA Image and Video Library

    1990-04-24

    Through the large window panes of Firing Room 1, KSC launch team members reap the rewards of their work with a glimpse of the space shuttle Discovery soaring into the sky. Discovery was launched for the tenth time at 8:34 a.m. EDT on April 24 beginning the five-day STS-31 mission to deploy the Hubble Space Telescope. A ray of morning sunlight highlights the red and white stripes of Old Glory hanging high in the Firing Room. Launch team members overcame a last minute challenge in the STS-31 countdown when software detected a main propulsion system valve was out of position. The situation was quickly corrected and verified by the team from consoles in the Firing Room and the countdown was returned in a matter of minutes. Photo credit: NASA

  9. KSC-90PC-0627

    NASA Image and Video Library

    1990-04-24

    Through the large window panes of Firing Room 1, KSC launch team members reap the rewards of their work with a glimpse of the space shuttle Discovery soaring into the sky. Discovery was launched for the tenth time at 8:34 a.m. EDT on April 24 beginning the five-day STS-31 mission to deploy the Hubble Space Telescope. A ray of morning sunlight highlights the red and white stripes of Old Glory hanging high in the Firing Room. Launch team members overcame a last minute challenge in the STS-31 countdown when software detected a main propulsion system valve was out of position. The situation was quickly corrected and verified by the team from consoles in the Firing Room and the countdown was returned in a matter of minutes. Photo credit: NASA

  10. Majority logic gate for 3D magnetic computing.

    PubMed

    Eichwald, Irina; Breitkreutz, Stephan; Ziemys, Grazvydas; Csaba, György; Porod, Wolfgang; Becherer, Markus

    2014-08-22

    For decades now, microelectronic circuits have been exclusively built from transistors. An alternative way is to use nano-scaled magnets for the realization of digital circuits. This technology, known as nanomagnetic logic (NML), may offer significant improvements in terms of power consumption and integration densities. Further advantages of NML are: non-volatility, radiation hardness, and operation at room temperature. Recent research focuses on the three-dimensional (3D) integration of nanomagnets. Here we show, for the first time, a 3D programmable magnetic logic gate. Its computing operation is based on physically field-interacting nanometer-scaled magnets arranged in a 3D manner. The magnets possess a bistable magnetization state representing the Boolean logic states '0' and '1.' Magneto-optical and magnetic force microscopy measurements prove the correct operation of the gate over many computing cycles. Furthermore, micromagnetic simulations confirm the correct functionality of the gate even for a size in the nanometer-domain. The presented device demonstrates the potential of NML for three-dimensional digital computing, enabling the highest integration densities.

  11. 75 FR 67947 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-04

    ... DEPARTMENT OF COMMERCE Submission for OMB Review; Comment Request The Department of Commerce will... unauthorized areas. Fishermen marking their gear correctly ultimately benefit, as unauthorized and illegal... Paperwork Clearance Officer, (202) 482-0266, Department of Commerce, Room 6616, 14th and Constitution Avenue...

  12. Cyber Space--with Elbow Room.

    ERIC Educational Resources Information Center

    Milshtein, Amy

    1998-01-01

    Describes how the Hammond School District (Indiana) solved the problem of fitting the correct amount of space needed for students, teachers, and technology. Examines the district's solutions for furniture needs through the use of full-scale mockups of classroom arrangements; and the wiring, power needs, and lighting. (GR)

  13. 76 FR 76386 - Marine Mammals; File No. 14241, Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-07

    ... Resources, NMFS, 1315 East-West Highway, Room 13705, Silver Spring, MD 20910; phone (301) 427-8401; fax (301) 713-0376; Northeast Region, NMFS, 55 Great Republic Drive, Gloucester, MA 01930; phone (978) 281-9300...; phone (727) 824-5312; fax (727) 824-5309. [[Page 76387

  14. Patient safety room of horrors: a novel method to assess medical students and entering residents' ability to identify hazards of hospitalisation.

    PubMed

    Farnan, Jeanne M; Gaffney, Sean; Poston, Jason T; Slawinski, Kris; Cappaert, Melissa; Kamin, Barry; Arora, Vineet M

    2016-03-01

    Patient safety curricula in undergraduate medical education (UME) are often didactic format with little focus on skills training. Despite recent focus on safety, practical training in residency education is also lacking. Assessments of safety skills in UME and graduate medical education (GME) are generally knowledge, and not application-focused. We aimed to develop and pilot a safety-focused simulation with medical students and interns to assess knowledge regarding hazards of hospitalisation. A simulation demonstrating common hospital-based safety threats was designed. A case scenario was created including salient patient information and simulated safety threats such as the use of upper-extremity restraints and medication errors. After entering the room and reviewing the mock chart, learners were timed and asked to identify and document as many safety hazards as possible. Learner satisfaction was assessed using constructed-response evaluation. Descriptive statistics, including per cent correct and mean correct hazards, were performed. All 86 third-year medical students completed the encounter. Some hazards were identified by a majority of students (fall risk, 83% of students) while others were rarely identified (absence of deep venous thrombosis prophylaxis, 13% of students). Only 5% of students correctly identified pressure ulcer risk. 128 of 131 interns representing 49 medical schools participated in the GME implementation. Incoming interns were able to identify a mean of 5.1 hazards out of the 9 displayed (SD 1.4) with 40% identifying restraints as a hazard, and 20% identifying the inappropriate urinary catheter as a hazard. A simulation showcasing safety hazards was a feasible and effective way to introduce trainees to safety-focused content. Both students and interns had difficulty identifying common hazards of hospitalisation. Despite poor performance, learners appreciated the interactive experience and its clinical utility. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. Numerical Modelling of Airflow and Temperature Distribution in a Living Room with Different Heat Exchange Conditions

    NASA Astrophysics Data System (ADS)

    Gendelis, S.; Jakovičs, A.

    2010-01-01

    Numerical mathematical modelling of the indoor thermal conditions and of the energy losses for separate rooms is an important part of the analysis of the heat-exchange balance and energy efficiency in buildings. The measurements of heat transfer coefficients for bounding structures, the air-tightness tests and thermographic diagnostics done for a building allow the influence of those factors to be predicted more correctly in developed numerical models. The temperature distribution and airflows in a typical room (along with the heat losses) were calculated for different heater locations and solar radiation (modelled as a heat source) through the window, as well as various pressure differences between the openings in opposite walls. The airflow velocities and indoor temperature, including its gradient, were also analysed as parameters of thermal comfort conditions. The results obtained show that all of the listed factors have an important influence on the formation of thermal comfort conditions and on the heat balance in a room.

  16. Microclimate monitoring of Ariadne’s house (Pompeii, Italy) for preventive conservation of fresco paintings

    PubMed Central

    2012-01-01

    Background Ariadne’s house, located at the city center of ancient Pompeii, is of great archaeological value due to the fresco paintings decorating several rooms. In order to assess the risks for long-term conservation affecting the valuable mural paintings, 26 temperature data-loggers and 26 relative humidity data-loggers were located in four rooms of the house for the monitoring of ambient conditions. Results Data recorded during 372 days were analyzed by means of graphical descriptive methods and analysis of variance (ANOVA). Results revealed an effect of the roof type and number of walls of the room. Excessive temperatures were observed during the summer in rooms covered with transparent roofs, and corrective actions were taken. Moreover, higher humidity values were recorded by sensors on the floor level. Conclusions The present work provides guidelines about the type, number, calibration and position of thermohygrometric sensors recommended for the microclimate monitoring of mural paintings in outdoor or semi-confined environments. PMID:23190798

  17. Episodic foresight beyond the very next event in 3- and 4-year-old children.

    PubMed

    Boden, Hannah; Labuschagne, Lisa G; Hinten, Ashley E; Scarf, Damian

    2017-11-01

    Testing episodic foresight in children generally involves presenting them with a problem in one location (e.g., Room A) and, after a spending a delay in a different location, telling them they will be returning to Room A. Before they go, children are presented with a number of items, one of which will allow them to solve the problem in Room A. At around 3 to 4 years of age children display episodic foresight, selecting the item that will allow them to solve the problem. To date, however, no study has assessed whether 3- and 4-year-old children can plan beyond the very next event, selecting the correct item when there is a delay before returning to Room A. Here, we show that 3- and 4-year-old children can pass when a delay is imposed but that their performance is significantly worse than when they are planning for an immediate event. © 2017 Wiley Periodicals, Inc.

  18. Measurement of total-body cobalt-57 vitamin B12 absorption with a gamma camera.

    PubMed

    Cardarelli, J A; Slingerland, D W; Burrows, B A; Miller, A

    1985-08-01

    Previously described techniques for the measurement of the absorption of [57Co]vitamin B12 by total-body counting have required an iron room equipped with scanning or multiple detectors. The present study uses simplifying modifications which make the technique more available and include the use of static geometry, the measurement of body thickness to correct for attenuation, a simple formula to convert the capsule-in-air count to a 100% absorption count, and finally the use of an adequately shielded gamma camera obviating the need of an iron room.

  19. A frameless stereotaxic operating microscope for neurosurgery.

    PubMed

    Friets, E M; Strohbehn, J W; Hatch, J F; Roberts, D W

    1989-06-01

    A new system, which we call the frameless stereotaxic operating microscope, is discussed. Its purpose is to display CT or other image data in the operating microscope in the correct scale, orientation, and position without the use of a stereotaxic frame. A nonimaging ultrasonic rangefinder allows the position of the operating microscope and the position of the patient to be determined. Discrete fiducial points on the patient's external anatomy are located in both image space and operating room space, linking the image data and the operating room. Physician-selected image information, e.g., tumor contours or guidance to predetermined targets, is projected through the optics of the operating microscope using a miniature cathode ray tube and a beam splitter. Projected images superpose the surgical field, reconstructed from image data to match the focal plane of the operating microscope. The algorithms on which the system is based are described, and the sources and effects of errors are discussed. The system's performance is simulated, providing an estimate of accuracy. Two phantoms are used to measure accuracy experimentally. Clinical results and observations are given.

  20. Installation and management of the SPS and LEP control system computers

    NASA Astrophysics Data System (ADS)

    Bland, Alastair

    1994-12-01

    Control of the CERN SPS and LEP accelerators and service equipment on the two CERN main sites is performed via workstations, file servers, Process Control Assemblies (PCAs) and Device Stub Controllers (DSCs). This paper describes the methods and tools that have been developed to manage the file servers, PCAs and DSCs since the LEP startup in 1989. There are five operational DECstation 5000s used as file servers and boot servers for the PCAs and DSCs. The PCAs consist of 90 SCO Xenix 386 PCs, 40 LynxOS 486 PCs and more than 40 older NORD 100s. The DSCs consist of 90 OS-968030 VME crates and 10 LynxOS 68030 VME crates. In addition there are over 100 development systems. The controls group is responsible for installing the computers, starting all the user processes and ensuring that the computers and the processes run correctly. The operators in the SPS/LEP control room and the Services control room have a Motif-based X window program which gives them, in real time, the state of all the computers and allows them to solve problems or reboot them.

  1. Temperature-Dependent Thermal Boundary Conductance of Monolayer MoS 2 by Raman Thermometry

    DOE PAGES

    Yalon, Eilam; Aslan, Ozgur Burak; Smithe, Kirby K. H.; ...

    2017-10-20

    The electrical and thermal behavior of nanoscale devices based on two-dimensional (2D) materials is often limited by their contacts and interfaces. Here we report the temperature-dependent thermal boundary conductance (TBC) of monolayer MoS 2 with AlN and SiO 2, using Raman thermometry with laser-induced heating. The temperature-dependent optical absorption of the 2D material is crucial in such experiments, which we characterize here for the first time above room temperature. We obtain TBC ~ 15 MW m –2 K –1 near room temperature, increasing as ~ T 0.65 in the range 300–600 K. The similar TBC of MoS 2 with themore » two substrates indicates that MoS 2 is the “softer” material with weaker phonon irradiance, and the relatively low TBC signifies that such interfaces present a key bottleneck in energy dissipation from 2D devices. As a result, our approach is needed to correctly perform Raman thermometry of 2D materials, and our findings are key for understanding energy coupling at the nanoscale.« less

  2. Temperature-Dependent Thermal Boundary Conductance of Monolayer MoS 2 by Raman Thermometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yalon, Eilam; Aslan, Ozgur Burak; Smithe, Kirby K. H.

    The electrical and thermal behavior of nanoscale devices based on two-dimensional (2D) materials is often limited by their contacts and interfaces. Here we report the temperature-dependent thermal boundary conductance (TBC) of monolayer MoS 2 with AlN and SiO 2, using Raman thermometry with laser-induced heating. The temperature-dependent optical absorption of the 2D material is crucial in such experiments, which we characterize here for the first time above room temperature. We obtain TBC ~ 15 MW m –2 K –1 near room temperature, increasing as ~ T 0.65 in the range 300–600 K. The similar TBC of MoS 2 with themore » two substrates indicates that MoS 2 is the “softer” material with weaker phonon irradiance, and the relatively low TBC signifies that such interfaces present a key bottleneck in energy dissipation from 2D devices. As a result, our approach is needed to correctly perform Raman thermometry of 2D materials, and our findings are key for understanding energy coupling at the nanoscale.« less

  3. [Plug-in Based Centralized Control System in Operating Rooms].

    PubMed

    Wang, Yunlong

    2017-05-30

    Centralized equipment controls in an operating room (OR) is crucial to an efficient workflow in the OR. To achieve centralized control, an integrative OR needs to focus on designing a control panel that can appropriately incorporate equipment from different manufactures with various connecting ports and controls. Here we propose to achieve equipment integration using plug-in modules. Each OR will be equipped with a dynamic plug-in control panel containing physically removable connecting ports. Matching outlets will be installed onto the control panels of each equipment used at any given time. This dynamic control panel will be backed with a database containing plug-in modules that can connect any two types of connecting ports common among medical equipment manufacturers. The correct connecting ports will be called using reflection dynamics. This database will be updated regularly to include new connecting ports on the market, making it easy to maintain, update, expand and remain relevant as new equipment are developed. Together, the physical panel and the database will achieve centralized equipment controls in the OR that can be easily adapted to any equipment in the OR.

  4. Mean-free-paths in concert and chamber music halls and the correct method for calibrating dodecahedral sound sources.

    PubMed

    Beranek, Leo L; Nishihara, Noriko

    2014-01-01

    The Eyring/Sabine equations assume that in a large irregular room a sound wave travels in straight lines from one surface to another, that the surfaces have an average sound absorption coefficient αav, and that the mean-free-path between reflections is 4 V/Stot where V is the volume of the room and Stot is the total area of all of its surfaces. No account is taken of diffusivity of the surfaces. The 4 V/Stot relation was originally based on experimental determinations made by Knudsen (Architectural Acoustics, 1932, pp. 132-141). This paper sets out to test the 4 V/Stot relation experimentally for a wide variety of unoccupied concert and chamber music halls with seating capacities from 200 to 5000, using the measured sound strengths Gmid and reverberation times RT60,mid. Computer simulations of the sound fields for nine of these rooms (of varying shapes) were also made to determine the mean-free-paths by that method. The study shows that 4 V/Stot is an acceptable relation for mean-free-paths in the Sabine/Eyring equations except for halls of unusual shape. Also demonstrated is the proper method for calibrating the dodecahedral sound source used for measuring the sound strength G, i.e., the reverberation chamber method.

  5. Thermal comfort assessment of a surgical room through computational fluid dynamics using local PMV index.

    PubMed

    Rodrigues, Nelson J O; Oliveira, Ricardo F; Teixeira, Senhorinha F C F; Miguel, Alberto Sérgio; Teixeira, José Carlos; Baptista, João S

    2015-01-01

    Studies concerning indoor thermal conditions are very important in defining the satisfactory comfort range in health care facilities. This study focuses on the evaluation of the thermal comfort sensation felt by surgeons and nurses, in an orthopaedic surgical room of a Portuguese hospital. Two cases are assessed, with and without the presence of a person. Computational fluid dynamic (CFD) tools were applied for evaluating the predicted mean vote (PMV) index locally. Using average ventilation values to calculate the PMV index does not provide a correct and enough descriptive evaluation of the surgical room thermal environment. As studied for both cases, surgeons feel the environment slightly hotter than nurses. The nurses feel a slightly cold sensation under the air supply diffuser and their neutral comfort zone is located in the air stagnation zones close to the walls, while the surgeons feel the opposite. It was observed that the presence of a person in the room leads to an increase of the PMV index for surgeons and nurses. That goes in line with the empirical knowledge that more persons in a room lead to an increased heat sensation. The clothing used by both classes, as well as the ventilation conditions, should be revised accordingly to the amount of persons in the room and the type of activity performed.

  6. Room To Grow? Facilities Programming for Colleges and Universities.

    ERIC Educational Resources Information Center

    Thompson, Roger; Adams, Tom

    2001-01-01

    Asserts that campus space needs could be remedied by moving centrally located service delivery organizations, such as fleet vehicle maintenance facilities. Describes the process of operational and space needs assessment; this process provides information that enables architects to plan for appropriate adjacencies, correct space allocation, and…

  7. Room temperature high-fidelity holonomic single-qubit gate on a solid-state spin.

    PubMed

    Arroyo-Camejo, Silvia; Lazariev, Andrii; Hell, Stefan W; Balasubramanian, Gopalakrishnan

    2014-09-12

    At its most fundamental level, circuit-based quantum computation relies on the application of controlled phase shift operations on quantum registers. While these operations are generally compromised by noise and imperfections, quantum gates based on geometric phase shifts can provide intrinsically fault-tolerant quantum computing. Here we demonstrate the high-fidelity realization of a recently proposed fast (non-adiabatic) and universal (non-Abelian) holonomic single-qubit gate, using an individual solid-state spin qubit under ambient conditions. This fault-tolerant quantum gate provides an elegant means for achieving the fidelity threshold indispensable for implementing quantum error correction protocols. Since we employ a spin qubit associated with a nitrogen-vacancy colour centre in diamond, this system is based on integrable and scalable hardware exhibiting strong analogy to current silicon technology. This quantum gate realization is a promising step towards viable, fault-tolerant quantum computing under ambient conditions.

  8. Extraction of 3D Information from Circular Array Measurements for Auralization with Wave Field Synthesis

    NASA Astrophysics Data System (ADS)

    de Vries, Diemer; Hörchens, Lars; Grond, Peter

    2007-12-01

    The state of the art of wave field synthesis (WFS) systems is that they can reproduce sound sources and secondary (mirror image) sources with natural spaciousness in a horizontal plane, and thus perform satisfactory 2D auralization of an enclosed space, based on multitrace impulse response data measured or simulated along a 2D microphone array. However, waves propagating with a nonzero elevation angle are also reproduced in the horizontal plane, which is neither physically nor perceptually correct. In most listening environments to be auralized, the floor is highly absorptive since it is covered with upholstered seats, occupied during performances by a well-dressed audience. A first-order ceiling reflection, reaching the floor directly or via a wall, will be severely damped and will not play a significant role in the room response anymore. This means that a spatially correct WFS reproduction of first-order ceiling reflections, by means of a loudspeaker array at the ceiling of the auralization reproduction room, is necessary and probably sufficient to create the desired 3D spatial perception. To determine the driving signals for the loudspeakers in the ceiling array, it is necessary to identify the relevant ceiling reflection(s) in the multichannel impulse response data and separate those events from the data set. Two methods are examined to identify, separate, and reproduce the relevant reflections: application of the Radon transform, and decomposition of the data into cylindrical harmonics. Application to synthesized and measured data shows that both methods in principle are able to identify, separate, and reproduce the relevant events.

  9. Object Permanence After a 24-Hr Delay and Leaving the Locale of Disappearance: The Role of Memory, Space, and Identity

    PubMed Central

    Moore, M. Keith; Meltzoff, Andrew N.

    2005-01-01

    Fourteen-month-old infants saw an object hidden inside a container and were removed from the disappearance locale for 24 hr. Upon their return, they searched correctly for the hidden object, demonstrating object permanence and long-term memory. Control infants who saw no disappearance did not search. In Experiment 2, infants returned to see the container either in the same or a different room. Performance by room-change infants dropped to baseline levels, suggesting that infant search for hidden objects is guided by numerical identity. Infants seek the individual object that disappeared, which exists in its original location, not in a different room. A new behavior, identity-verifying search, was discovered and quantified. Implications are drawn for memory, spatial understanding, object permanence, and object identity. PMID:15238047

  10. Object permanence after a 24-hr delay and leaving the locale of disappearance: the role of memory, space, and identity.

    PubMed

    Moore, M Keith; Meltzoff, Andrew N

    2004-07-01

    Fourteen-month-old infants saw an object hidden inside a container and were removed from the disappearance locale for 24 hr. Upon their return, they searched correctly for the hidden object, demonstrating object permanence and long-term memory. Control infants who saw no disappearance did not search. In Experiment 2, infants returned to see the container either in the same or a different room. Performance by room-change infants dropped to baseline levels, suggesting that infant search for hidden objects is guided by numerical identity. Infants seek the individual object that disappeared, which exists in its original location, not in a different room. A new behavior, identity-verifying search, was discovered and quantified. Implications are drawn for memory, spatial understanding, object permanence, and object identity. Copyright 2004 APA, all rights reserved

  11. Occupational Injury and Treatment Patterns of Migrant and Seasonal Farmworkers

    PubMed Central

    Brower, Melissa A.; Earle-Richardson, Giulia B.; May, John J.; Jenkins, Paul L.

    2010-01-01

    Migrant and seasonal farmworkers are thought to be at increased risk for occupational injury and illness. Past surveillance efforts that employed medical chart review may not be representative of all farmworkers, since the proportion of farmworkers using migrant health centers (MHC) and area hospital emergency rooms (ER) was unknown. The purpose of the current study was to determine the proportion of workers using MHCs versus other sources of occupational health care, and to use this data to correct previous occupational injury and illness rate estimates. Researchers conducted a survey of migrant and seasonal farmworkers in two sites: the Finger Lakes Region of New York and the apple, broccoli and blueberry regions of Maine. Researchers also conducted MHC and ER medical chart reviews in these regions for comparison purposes. Proportions of occupational morbidity by treatment location were calculated from the survey, and a correction factor was computed to adjust chart review morbidity estimates for Maine and New York State. Among 1,103 subjects, 56 work-related injuries were reported: 30 (53.6%) were treated at a MHC, 8 (14.3%) at an ER, 9 (16.1%) at some other location (e.g., home, relative, chiropractor), and 9 (16.1%) were untreated. Mechanisms of injuries treated at MHCs versus all other sources did not differ significantly. The survey-based multiplier (1.87) was applied to previous statewide MHC chart review injury counts from Maine and New York. The corrected injury rates were 7.9 per 100 full time equivalents (FTE) per year in Maine, and 11.7 per 100 FTE in New York. A chart-review based surveillance system, combined with a correction factor, may provide an effective method of estimating occupational illness and injury rates in this population. PMID:19437274

  12. High-resolution ionization detector and array of such detectors

    DOEpatents

    McGregor, Douglas S [Ypsilanti, MI; Rojeski, Ronald A [Pleasanton, CA

    2001-01-16

    A high-resolution ionization detector and an array of such detectors are described which utilize a reference pattern of conductive or semiconductive material to form interaction, pervious and measurement regions in an ionization substrate of, for example, CdZnTe material. The ionization detector is a room temperature semiconductor radiation detector. Various geometries of such a detector and an array of such detectors produce room temperature operated gamma ray spectrometers with relatively high resolution. For example, a 1 cm.sup.3 detector is capable of measuring .sup.137 Cs 662 keV gamma rays with room temperature energy resolution approaching 2% at FWHM. Two major types of such detectors include a parallel strip semiconductor Frisch grid detector and the geometrically weighted trapezoid prism semiconductor Frisch grid detector. The geometrically weighted detector records room temperature (24.degree. C.) energy resolutions of 2.68% FWHM for .sup.137 Cs 662 keV gamma rays and 2.45% FWHM for .sup.60 Co 1.332 MeV gamma rays. The detectors perform well without any electronic pulse rejection, correction or compensation techniques. The devices operate at room temperature with simple commercially available NIM bin electronics and do not require special preamplifiers or cooling stages for good spectroscopic results.

  13. 76 FR 31341 - President's Committee for People With Intellectual Disabilities; Notice of Correction of Room for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-31

    ... Genevieve Swift, PCPID Executive Administrative Assistant, via e-mail at Edith.Swift@acf.hhs.gov , or via... contact Laverdia Taylor Roach, Director, President's Committee for People with Intellectual Disabilities... and universally designed technologies. Dated: May 24, 2011. Laverdia Taylor Roach, Director, PCPID...

  14. 75 FR 12989 - Hazardous Waste Technical Corrections and Clarifications Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-18

    ... regulations that relate to hazardous waste identification, manifesting, the hazardous waste generator..., NW., Washington, DC 20460. Attention Docket ID No. EPA-HQ-RCRA-2008-0678. Please include a total of 2 copies. Hand Delivery: EPA West Building, Room 3334, 1301 Constitution Ave., NW., Washington, DC. Such...

  15. Using Structured Examples and Prompting Reflective Questions to Correct Misconceptions about Thermodynamic Concepts

    ERIC Educational Resources Information Center

    Olakanmi, E. O.; Doyoyo, M.

    2014-01-01

    This paper explores the effectiveness of using "structured examples in concert with prompting reflective questions" to address misconceptions held by mechanical engineering students about thermodynamic principles by employing pre-test and post-test design, a structured questionnaire, lecture room observation, and participants'…

  16. 77 FR 25587 - Anchorage Regulations; Wells, ME

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-01

    ... anchorage areas were out of sequence and formed an hourglass shaped anchorage. This direct final rule corrects the sequence of the coordinates so that the anchorage area forms a box-like shaped anchorage...), U.S. Department of Transportation, West Building Ground Floor, Room W12-140, 1200 New Jersey Avenue...

  17. 49 CFR Appendix E to Part 227 - Use of Insert Earphones for Audiometric Testing

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION OCCUPATIONAL NOISE EXPOSURE Pt. 227, App. E Appendix.... B. Technicians who conduct audiometric tests must be trained to insert the earphones correctly into... audiometer. IV. Background Noise Levels Testing shall be conducted in a room where the background ambient...

  18. 75 FR 32372 - Marine Mammals; File No. 14241, Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... East-West Highway, Room 13705, Silver Spring, MD 20910; phone (301)713-2289; fax (301)713-0376; Northeast Region, NMFS, 55 Great Republic Drive, Gloucester, MA 01930; phone (978)281-9300; fax (978)281-9333; and Southeast Region, NMFS, 263 13th Avenue South, Saint Petersburg, Florida 33701; phone (727...

  19. PFP Emergency Lighting Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BUSCH, M.S.

    2000-02-02

    NFPA 101, section 5-9 mandates that, where required by building classification, all designated emergency egress routes be provided with adequate emergency lighting in the event of a normal lighting outage. Emergency lighting is to be arranged so that egress routes are illuminated to an average of 1.0 footcandle with a minimum at any point of 0.1 footcandle, as measured at floor level. These levels are permitted to drop to 60% of their original value over the required 90 minute emergency lighting duration after a power outage. The Plutonium Finishing Plant (PFP) has two designations for battery powered egress lights ''Emergencymore » Lights'' are those battery powered lights required by NFPA 101 to provide lighting along officially designated egress routes in those buildings meeting the correct occupancy requirements. Emergency Lights are maintained on a monthly basis by procedure ZSR-12N-001. ''Backup Lights'' are battery powered lights not required by NFPA, but installed in areas where additional light may be needed. The Backup Light locations were identified by PFP Safety and Engineering based on several factors. (1) General occupancy and type of work in the area. Areas occupied briefly during a shiftly surveillance do not require backup lighting while a room occupied fairly frequently or for significant lengths of time will need one or two Backup lights to provide general illumination of the egress points. (2) Complexity of the egress routes. Office spaces with a standard hallway/room configuration will not require Backup Lights while a large room with several subdivisions or irregularly placed rooms, doors, and equipment will require Backup Lights to make egress safer. (3) Reasonable balance between the safety benefits of additional lighting and the man-hours/exposure required for periodic light maintenance. In some plant areas such as building 236-Z, the additional maintenance time and risk of contamination do not warrant having Backup Lights installed in all rooms. Sufficient light for egress is provided by existing lights located in the hallways.« less

  20. Creating Engaging Escape Rooms for the Classroom

    ERIC Educational Resources Information Center

    Nicholson, Scott

    2018-01-01

    Escape rooms are "live-action team-based games where players discover clues, solve puzzles, and accomplish tasks in one or more rooms in order to accomplish a specific goal (usually escaping from the room) in a limited amount of time." Escape Rooms are one type of Escape Game, which are narrative-based challenges that use puzzles, tasks,…

  1. Anesthetic level prediction using a QCM based E-nose.

    PubMed

    Saraoğlu, H M; Ozmen, A; Ebeoğlu, M A

    2008-06-01

    Anesthetic level measurement is a real time process. This paper presents a new method to measure anesthesia level in surgery rooms at hospitals using a QCM based E-Nose. The E-Nose system contains an array of eight different coated QCM sensors. In this work, the best linear reacting sensor is selected from the array and used in the experiments. Then, the sensor response time was observed about 15 min using classic method, which is impractical for on-line anesthetic level detection during a surgery. Later, the sensor transition data is analyzed to reach a decision earlier than the classical method. As a result, it is found out that the slope of transition data gives valuable information to predict the anesthetic level. With this new method, we achieved to find correct anesthetic levels within 100 s.

  2. Indoor Noise Loading in Residential Prefabricated Buildings

    NASA Astrophysics Data System (ADS)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.

  3. Users’ dissatisfaction with dental care: a population-based household study

    PubMed Central

    Martins, Andréa Maria Eleutério de Barros Lima; Ferreira, Raquel Conceição; dos Santos, Pedro Eleutério; Carreiro, Danilo Lima; Souza, João Gabriel Silva; Ferreira e Ferreira, Efigênia

    2015-01-01

    OBJECTIVE To examine whether demographic, socioeconomic conditions, oral health subjectivity and characterization of dental care are associated with users’ dissatisfaction with such are. METHODS Cross-sectional study of 781 people who required dental care in Montes Claros, MG, Southeastern Brazil, in 2012, a city with of medium-sized population situated in the North of Minas Gerais. Household interviews were conducted to assess the users’ dissatisfaction with dental care (dependent variable), demographic, socioeconomic conditions, oral health subjectivity and characterization of dental care (independent variables). Sample calculation was used for the finite population, with estimates made for proportions of dissatisfaction in 50.0% of the population, a 5.0% error margin, a non-response rate of 5.0% and a 2.0% design effect. Logistic regression was used, and the odds ratio was calculated with a 5% significance level and 95% confidence intervals. RESULTS Of the interviewed individuals, 9.0% (7.9%, with correction for design effect) were dissatisfied with the care provided. These were associated with lower educational level; negative self-assessment of oral health; perception that the care provider was unable to give dental care; negative evaluation of the way the patient was treated, the cleanliness of the rooms, based on the examination rooms and the toilets, and the size of the waiting and examination rooms. CONCLUSIONS The rate of dissatisfaction with dental care was low. This dissatisfaction was associated with socioeconomic conditions, subjectivity of oral health, skill of the health professionals relating to the professional-patient relationship and facility infrastructure. Educational interventions are suggested that aim at improving the quality of care among professionals by responsible agencies as is improving the infrastructure of the care units. PMID:26270017

  4. Psychotherapy for Depression in Older Veterans Via Telemedicine: Effect on Quality of Life, Satisfaction, Treatment Credibility, and Service Delivery Perception.

    PubMed

    Egede, Leonard E; Acierno, Ron; Knapp, Rebecca G; Walker, Rebekah J; Payne, Elizabeth H; Frueh, B Christopher

    2016-12-01

    To analyze the impact of telepsychology and same-room care on functioning, satisfaction, and perception of care based on a noninferiority trial of psychotherapy delivered via telemedicine or same-room care to elderly patients with depression. 241 elderly patients with depression (meeting DSM-IV diagnostic criteria) were randomly assigned to either telemedicine (n = 120) or same-room treatment (n = 121) between April 1, 2007, and July 31, 2011. The primary outcomes included quality of life (36-item Short Form Survey [SF-36]), satisfaction (Charleston Psychiatric Outpatient Satisfaction Scale), treatment credibility, and service delivery perception scores obtained at 4 weeks, 8 weeks, 3 months, and 12 months. Comparisons of intervention means were carried out at each time point using independent sample t tests and SAS Procedure MIANALYZE to combine results across the multiply imputed complete data sets. If significant differences were detected for a given outcome within a domain, a Bonferroni correction was applied to determine if significance was maintained. None of the SF-36 scores showed a significant difference between the 2 treatment groups by the end of the study period, with little significance shown throughout the intermediate time points. Similarly, over all time points, there was no statistically significant difference in patient satisfaction or treatment credibility. This study found that telemedicine is a viable alternative modality for providing evidence-based psychotherapy for elderly patients with depression. Results provide evidence that quality of life and satisfaction with care are not adversely influenced by the decision to use a telehealth modality instead of in-person treatment, and, as a result, resources can be devoted to offering services in patients' homes through telemedicine. ClinicalTrials.gov identifier: NCT00324701. © Copyright 2016 Physicians Postgraduate Press, Inc.

  5. Delivery room management of term and preterm newly born infants.

    PubMed

    Saugstad, Ola Didrik

    2015-01-01

    Delivery room management, especially in the first 'golden' minute, is of the utmost importance. An exact and universal definition of when a baby is born is needed to obtain agreement on what is meant by the first minute of life. Education of young girls is a basic requirement to optimize the health of the mother and baby. Interventions in pregnancy should as far as possible be evidence based. Antenatal care, the selection of birth mode and antenatal steroid therapy when indicated also contribute to obtaining the best outcome. Delayed cord clamping is recommended for both preterm and term infants. However, more data are needed regarding the most immature infants. Routine suctioning of the mouth and airways is not required. Thermal control is important - keep the temperature in the delivery room at 26°C and wrap infants <28 weeks of gestation in plastic. However, this procedure does not reduce mortality. Since delayed cord clamping increases mean birth weight by approximately 30 g/kg, the present birth weight charts based on early clamping need to be corrected. Preterm infants in need of ventilatory support should start with CPAP from the first breath. A T-piece device seems to have some advantages compared to self-inflating bags. Surfactant instillation is often not needed prophylactically provided the mother has received antenatal steroids. Less invasive methods for administering surfactant may be useful. If ventilatory support is needed, start with air in term and near-term infants. For babies of 29-33 weeks of gestation start with 21-30% oxygen and for infants <29 weeks start with 30% oxygen and adjust according to the response obtained. © 2015 S. Karger AG, Basel.

  6. How to find the way out from four rooms? The learning of "chaining" associations may shed light on the neuropsychology of the deficit syndrome of schizophrenia.

    PubMed

    Polgár, Patricia; Farkas, Márta; Nagy, Orsolya; Kelemen, Oguz; Réthelyi, János; Bitter, István; Myers, Catherine E; Gluck, Mark A; Kéri, Szabolcs

    2008-02-01

    Recent meta-analytic evidence suggests that clinical neuropsychological methods are not likely to uncover circumscribed cognitive impairments in the deficit syndrome of schizophrenia. To overcome this issue, we adapted a cognitive neuroscience perspective and used a new "chaining" habit learning task. Participants were requested to navigate a cartoon character through a sequence of 4 rooms by learning to choose the open door from 3 colored doors in each room. The aim of the game was to learn the full sequence of rooms until the character reached the outside. In the training phase, each stimulus leading to reward (open door in each room) was trained via feedback until the complete sequence was learned. In the probe phase, the context of rewarded stimuli was manipulated: in a given room, in addition to the correct door of that room, there also appeared a door which was open in another room. Whereas the training phase is dominantly related to basal ganglia circuits, the context-dependent probe phase requires intact medial-temporal lobe functioning. Results revealed that deficit and non-deficit patients were similarly impaired on the probe phase compared with controls. However, the training phase was only compromised in deficit patients. More severe negative symptoms were associated with more errors on the training phase. Executive functions were unrelated to performance on the "chaining" task. These results indicate that the deficit syndrome is associated with prominently impaired stimulus-response reinforcement learning, which may indicate abnormal functioning of basal ganglia circuits.

  7. Laparoscopy Using Room Air Insufflation in a Rural African Jungle Hospital: The Bongolo Hospital Experience, January 2006 to December 2013.

    PubMed

    O'Connor, Zachary; Faniriko, Marco; Thelander, Keir; O'Connor, Jennifer; Thompson, David; Park, Adrian

    2017-06-01

    Carbon dioxide is the standard insufflation gas for laparoscopy. However, in many areas of the world, bottled carbon dioxide is not available. Laparoscopy offers advantages over open surgery and has been practiced using filtered room air insufflation since 2006 at Bongolo Hospital in Gabon, Africa. Our primary goal was to evaluate the safety of room air insufflation related to intraoperative and postoperative complications. Our secondary aim was to review the types of cases performed laparoscopically at our institution. This retrospective review evaluates laparoscopic cases performed at Bongolo Hospital between January 2006 and December 2013. Demographic and perioperative information for patients undergoing laparoscopic procedures was collected. Insufflation was achieved using a standard, oil-free air compressor using filtered air and a standard insufflation regulator. A total of 368 laparoscopic procedures were identified within the time period. The majority of cases were gynecologic (43%). There was a 2% (8/368) complication rate with one perioperative death. The 2 complications related to insufflation were episodes of hypotension responsive to standard corrective measures. No intracorporeal combustion events were observed in any cases in which the use of diathermy and room air insufflation were combined. The other complications and the death were unrelated to the use of insufflation with air. Insufflation complications with room air occurred in our study. However, the complications related to insufflation with room air in our study were no different than those described in the literature using carbon dioxide. As room air is less costly than carbon dioxide and readily available, confirming the safety of room air insufflation in prospective studies is warranted. Room air appears to be safe for establishing and maintaining pneumoperitoneum, making laparoscopic surgery more accessible to patients in low-resource settings.

  8. Uses of tuberculosis mortality surveillance to identify programme errors and improve database reporting.

    PubMed

    Selig, L; Guedes, R; Kritski, A; Spector, N; Lapa E Silva, J R; Braga, J U; Trajman, A

    2009-08-01

    In 2006, 848 persons died from tuberculosis (TB) in Rio de Janeiro, Brazil, corresponding to a mortality rate of 5.4 per 100 000 population. No specific TB death surveillance actions are currently in place in Brazil. Two public general hospitals with large open emergency rooms in Rio de Janeiro City. To evaluate the contribution of TB death surveillance in detecting gaps in TB control. We conducted a survey of TB deaths from September 2005 to August 2006. Records of TB-related deaths and deaths due to undefined causes were investigated. Complementary data were gathered from the mortality and TB notification databases. Seventy-three TB-related deaths were investigated. Transmission hazards were identified among firefighters, health care workers and in-patients. Management errors included failure to isolate suspected cases, to confirm TB, to correct drug doses in underweight patients and to trace contacts. Following the survey, 36 cases that had not previously been notified were included in the national TB notification database and the outcome of 29 notified cases was corrected. TB mortality surveillance can contribute to TB monitoring and evaluation by detecting correctable and specific programme- and hospital-based care errors, and by improving the accuracy of TB database reporting. Specific local and programmatic interventions can be proposed as a result.

  9. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†

    PubMed Central

    Pröfrock, Daniel; Irrgeher, Johanna; Prohaska, Thomas

    2016-01-01

    The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3–0.5% (uc,rel), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement uc,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%). PMID:27812369

  10. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements.

    PubMed

    Hanousek, Ondrej; Brunner, Marion; Pröfrock, Daniel; Irrgeher, Johanna; Prohaska, Thomas

    2016-11-14

    The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3-0.5% ( u c,rel ), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement u c,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%).

  11. A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector

    PubMed Central

    Therriault-Proulx, Francois; Wootton, Landon; Beddar, Sam

    2015-01-01

    Plastic scintillation detectors (PSDs) work well for radiation dosimetry. However, they show some temperature dependence, and a priori knowledge of the temperature surrounding the PSD is required to correct for this dependence. We present a novel approach to correct PSD response values for temperature changes instantaneously and without the need for prior knowledge of the temperature value. In addition to rendering the detector temperature-independent, this approach allows for actual temperature measurement using solely the PSD apparatus. With a temperature-controlled water tank, the temperature was varied from room temperature to more than 40°C and the PSD was used to measure the dose delivered from a cobalt-60 photon beam unit to within an average of 0.72% from the expected value. The temperature was measured during each acquisition with the PSD and a thermocouple and values were within 1°C of each other. The depth-dose curve of a 6-MV photon beam was also measured under warm non-stable conditions and this curve agreed to within an average of −0.98% from the curve obtained at room temperature. The feasibility of rendering PSDs temperature-independent was demonstrated with our approach, which also enabled simultaneous measurement of both dose and temperature. This novel approach improves both the robustness and versatility of PSDs. PMID:26407188

  12. 40 CFR 60.1685 - What if all the certified operators must be temporarily offsite?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... onsite. (2) Submit a status report and corrective action summary to the Administrator every 4 weeks... hours, but for 2 weeks or less, and no other certified operator is onsite, the provisionally certified... weeks, and no other certified operator is onsite, the provisionally certified control room operator may...

  13. 77 FR 63714 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-17

    .... ACTION: Final rule. SUMMARY: We are adopting a new airworthiness directive (AD) for certain The Boeing... instructions and doing the work specified in those instructions. We are issuing this AD to detect and correct..., Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590. FOR FURTHER INFORMATION CONTACT: Kelly...

  14. Reorienting in Images of a Three-Dimensional Environment

    ERIC Educational Resources Information Center

    Kelly, Debbie M.; Bischof, Walter F.

    2005-01-01

    Adult humans searched for a hidden goal in images depicting 3-dimensional rooms. Images contained either featural cues, geometric cues, or both, which could be used to determine the correct location of the goal. In Experiment 1, participants learned to use featural and geometric information equally well. However, men and women showed significant…

  15. 76 FR 50276 - STP Nuclear Operating Company, South Texas Project, Units 1 and 2; Notice of Withdrawal of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-12

    ... revised the application of Risk- Managed Technical Specifications to Technical Specification 3.7.7, ``Control Room Makeup and Cleanup Filtration System.'' The purpose of the change was to correct a misapplication of the Configuration Risk Management Program that is currently allowed by the Technical...

  16. 77 FR 43547 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-25

    ...). SUMMARY: We propose to adopt a new airworthiness directive (AD) for certain The Boeing Company Model 737... stringers S-22 and S-23, left and right sides; and corrective actions and preventive modification if... Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590...

  17. Transfrontal orbitotomy in the dog: an adaptable three-step approach to the orbit.

    PubMed

    Håkansson, Nils Wallin; Håkansson, Berit Wallin

    2010-11-01

    To describe an adaptable and extensive method for orbitotomy in the dog. An adaptable three-step technique for orbitotomy was developed and applied in nine consecutive cases. The steps are zygomatic arch resection laterally, temporalis muscle elevation medially and zygomatic process osteotomy anteriorly-dorsally. The entire orbit is accessed with excellent exposure and room for surgical manipulation. Facial nerve, lacrimal nerve and lacrimal gland function are preserved. The procedure can easily be converted into an orbital exenteration. Exposure of the orbit was excellent in all cases and anatomically correct closure was achieved. Signs of postoperative discomfort were limited, with moderate, reversible swelling in two cases and mild in seven. Wound infection or emphysema did not occur, nor did any other complication attributable to the operative procedure. Blinking ability and lacrimal function were preserved over follow-up times ranging from 1 to 4 years. Transfrontal orbitotomy in the dog offers excellent exposure and room for manipulation. Anatomically correct closure is easily accomplished, postoperative discomfort is limited and complications are mild and temporary. © 2010 American College of Veterinary Ophthalmologists.

  18. Towards in vivo amplification: Overcoming hurdles in the use of hematopoietic stem cells in transplantation and gene therapy

    PubMed Central

    Nagree, Murtaza S; López-Vásquez, Lucía; Medin, Jeffrey A

    2015-01-01

    With the advent of safer and more efficient gene transfer methods, gene therapy has become a viable solution for many inherited and acquired disorders. Hematopoietic stem cells (HSCs) are a prime cell compartment for gene therapy aimed at correcting blood-based disorders, as well as those amenable to metabolic outcomes that can effect cross-correction. While some resounding clinical successes have recently been demonstrated, ample room remains to increase the therapeutic output from HSC-directed gene therapy. In vivo amplification of therapeutic cells is one avenue to achieve enhanced gene product delivery. To date, attempts have been made to provide HSCs with resistance to cytotoxic drugs, to include drug-inducible growth modules specific to HSCs, and to increase the engraftment potential of transduced HSCs. This review aims to summarize amplification strategies that have been developed and tested and to discuss their advantages along with barriers faced towards their clinical adaptation. In addition, next-generation strategies to circumvent current limitations of specific amplification schemas are discussed. PMID:26730268

  19. Motion correction for radiation therapy of prostate using B-mode ultrasound

    NASA Astrophysics Data System (ADS)

    Hummel, Johann; Figl, Michael; Schmidbauer, Jörg; Tinzl, Martina; Bergmann, Helmar; Birkfellner, Wolfgang

    2007-03-01

    The use of intensity modulated radiation therapy promises to spare organs at risk by applying better dose distribution on the tumor. The specific challenge of this methods is the exact positioning of the patient and the localization of the exposured organ. With respect to the filling of rectum and bladder the prostate can move several millimeters up to centimeters. Therefore, the position of the prostate should be determinated and corrected daily before irradiation. We used a B-mode US machine (Ultramark 9, advanced Technology Laboratories, USA) which was calibrated using an optical tracking system (Polaris, NDI, Can). After correct positioning of the patient in the simulation room three anatomical markers (apex prostate, prostate lateral sinister/dexter) were identified and their positions calculated with respect to the coordinate system of the simulator. The same situation is given in the treatment room. Both, simulator and accelerator are registered by a simple point-to-point registration using a block with five drilled holes with known coordinates in the block coordinate system. The block is aligned by means of laser markers. When the patient is placed on the treatment table, the three anatomical landmarks are located on the US images and their positions are calculated with respect to the coordinate system of the treatment room. Applying a point-to-point registration results in a rotation matrix and a translation vector in the desired coordinate system which can be used for repositioning by translating and rotating the patient table. Additionally, a fiducial registration error (FRE) is calculated which gives a dimension of the accuracy the three points were identified. We found an fiducial registration error (FRE) of 2.4 mm +/- 1.2 mm for the point-to-point registration of the anatomical landmarks. The FRE for the point-to-point registration between the block and the optical tracking system was 0.5 mm +/- 0.2 mm. According to the US calibration we found an error of 0.8 mm +/- 0.2 mm.

  20. Delivery room triage of large for gestational age infants of diabetic mothers.

    PubMed

    Cordero, Leandro; Rath, Krista; Zheng, Katherine; Landon, Mark B; Nankervis, Craig A

    2014-01-01

    To review our 4-year experience (2008-2011) with delivery room triage of large for gestational age infants of diabetic mothers. Retrospective cohort investigation of 311 large for gestational age infants of diabetic mothers (White's Class A1 (77), A2 (87), B (77), and C-R (70)). Of 311 women, 31% delivered at 34-36 weeks gestational age and 69% at term. While 70% were delivered by cesarean, 30% were vaginal deliveries. A total of 160 asymptomatic infants were triaged from the delivery room to the well baby nursery. Of these, 55 (34%) developed hypoglycemia. In 43 cases, the hypoglycemia was corrected by early feedings; in the remaining 12, intravenous dextrose treatment was required. A total of 151 infants were triaged from the delivery room to the neonatal intensive care unit. Admission diagnoses included respiratory distress (51%), prevention of hypoglycemia (27%), prematurity (21%), and asphyxia (1%). Hypoglycemia affected 66 (44%) of all neonatal intensive care unit infants. Safe triage of asymptomatic large for gestational age infants of diabetic mothers from the delivery room to well baby nursery can be accomplished in the majority of cases. Those infants in need of specialized care can be accurately identified and effectively treated in the neonatal intensive care unit setting.

  1. Containment testing of isolation rooms.

    PubMed

    Rydock, J P; Eian, P K

    2004-07-01

    Results from the tracer containment testing of four 'state-of-the-art' airborne infection isolation rooms, in a new hospital, are presented. A testing technician exited an isolation room several minutes after a small quantity of tracer gas was injected over the patient bed in that room. Easily measurable tracer gas concentrations were then found in the anterooms outside the patient rooms and corridor outside the isolation room suites. Containment factors for the isolation rooms and dilution factors in the anterooms and corridor were calculated, based on the measured tracer concentrations. These results indicate the desirability of evidence-based design standards and guidelines for assessing performance of airborne infection isolation rooms. The study also demonstrates that the tracer testing procedure yields comparable results for equivalent isolation room suites, suggesting good reproducibility of the testing method.

  2. Bio-inspired color image enhancement

    NASA Astrophysics Data System (ADS)

    Meylan, Laurence; Susstrunk, Sabine

    2004-06-01

    Capturing and rendering an image that fulfills the observer's expectations is a difficult task. This is due to the fact that the signal reaching the eye is processed by a complex mechanism before forming a percept, whereas a capturing device only retains the physical value of light intensities. It is especially difficult to render complex scenes with highly varying luminances. For example, a picture taken inside a room where objects are visible through the windows will not be rendered correctly by a global technique. Either details in the dim room will be hidden in shadow or the objects viewed through the window will be too bright. The image has to be treated locally to resemble more closely to what the observer remembers. The purpose of this work is to develop a technique for rendering images based on human local adaptation. We take inspiration from a model of color vision called Retinex. This model determines the perceived color given spatial relationships of the captured signals. Retinex has been used as a computational model for image rendering. In this article, we propose a new solution inspired by Retinex that is based on a single filter applied to the luminance channel. All parameters are image-dependent so that the process requires no parameter tuning. That makes the method more flexible than other existing ones. The presented results show that our method suitably enhances high dynamic range images.

  3. Aberration-Corrected STEM Imaging Through Off-Site Remote Operation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jarvis, Karalee; Allard Jr, Lawrence Frederick; Jerome, Timothy Y

    2010-01-01

    Recent advances in aberration-corrected electron microscopy have allowed researchers to image materials at sub- ngstr m resolution. Many of these modern instruments are designed to be operated from separate 'control' rooms, removing the effect of the operator on the instrument s physical environment. This capability also allows operation from suitable workstations, over internet connections, from literally anywhere in the world [1]. Researchers at the University of Texas at Austin (UTA) have collaborated with Oak Ridge National Laboratory (ORNL) and JEOL Ltd. to routinely conduct research sessions in which high-resolution images and X-ray microanalytical data are acquired during after-hours research sessions,more » utilizing the JEOL 2200FS aberration-corrected STEM/TEM at ORNL from their lab in Austin. Details of the remote operation are presented here.« less

  4. Influence of nanofillers on the thermal and mechanical behavior of DGEBA-based adhesives for bonded-in timber connections

    NASA Astrophysics Data System (ADS)

    Ahmad, Z.; Ansell, M. P.; Smedley, D.

    2006-09-01

    Results of an experimental investigation into the thermal behavior and mechanical properties of a room-temperature-cured epoxy adhesive (diglycidyl ether of bisphenol A, DGEBA) cross-linked with polyetheramines and filled with different fillers, namely nanosilica, liquid rubber (CTBN), and clay, are reported. The nanosilica and liquid rubber increased the flexural strength and elastic modulus of the adhesive systems; the addition of clay particles raised the elastic modulus significantly, but embrittled the adhesive. Establishing a correct cure time is very important for bonded-in timber structures, as it will affect the bond strength. A study on the effect of cure time on the flexural strength was carried out, from which it follows that the adhesives should be cured for at least 20 days at room temperature. The damping characteristics and the glass-transition temperature of the adhesives were determined by using a dynamic mechanical thermal analysis. The results showed that the filled adhesives had a higher storage modulus, which was in agreement with the elastic moduli determined from static bending tests. The introduction of the fillers increased its glass-transition temperature considerably.

  5. A simulation model of hospital management based on cost accounting analysis according to disease.

    PubMed

    Tanaka, Koji; Sato, Junzo; Guo, Jinqiu; Takada, Akira; Yoshihara, Hiroyuki

    2004-12-01

    Since a little before 2000, hospital cost accounting has been increasingly performed at Japanese national university hospitals. At Kumamoto University Hospital, for instance, departmental costs have been analyzed since 2000. And, since 2003, the cost balance has been obtained according to certain diseases for the preparation of Diagnosis-Related Groups and Prospective Payment System. On the basis of these experiences, we have constructed a simulation model of hospital management. This program has worked correctly at repeated trials and with satisfactory speed. Although there has been room for improvement of detailed accounts and cost accounting engine, the basic model has proved satisfactory. We have constructed a hospital management model based on the financial data of an existing hospital. We will later improve this program from the viewpoint of construction and using more various data of hospital management. A prospective outlook may be obtained for the practical application of this hospital management model.

  6. How to Design and Equip a Mentalization-Based Play Therapy Room.

    PubMed

    Rüth, Ulrich; Holch, Astrid

    2018-01-01

    Designing and equipping a play therapy room as a differentiated tool in a psychodynamic approach to child psychotherapy is seldom discussed. This article sketches out the equipment and furnishing of a play therapy room to be used for mentalization-based psychodynamic psychotherapy and gives examples of the use of such a room in practice.

  7. 40 CFR 62.15140 - What if all the certified operators must be temporarily offsite?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... more than 12 hours, but for 2 weeks or less, and no other certified operator is onsite, the... more than 2 weeks and no other certified operator is onsite, the provisionally certified control room... supervisor is onsite. (2) Submit a status report and corrective action summary to the Administrator every 4...

  8. 40 CFR 62.15140 - What if all the certified operators must be temporarily offsite?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... more than 12 hours, but for 2 weeks or less, and no other certified operator is onsite, the... more than 2 weeks and no other certified operator is onsite, the provisionally certified control room... supervisor is onsite. (2) Submit a status report and corrective action summary to the Administrator every 4...

  9. 40 CFR 86.522-78 - Carbon monoxide analyzer calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... performance on the most sensitive range. (2) Zero the carbon monoxide analyzer with either zero grade air or zero grade nitrogen. (3) Bubble a mixture of 3 percent CO2 in N2 through water at room temperature and... action. (Use of conditioning columns is one form of corrective action which may be taken.) (b) Initial...

  10. 77 FR 63282 - Airworthiness Directives; Bombardier Inc. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-16

    ... specified in certain temporary revisions. We are proposing this AD to detect and correct fatigue cracking in..., Room W12-140, 1200 New Jersey Avenue SE., Washington, DC, between 9 a.m. and 5 p.m., Monday through....regulations.gov ; or in person at the Docket Operations office between 9 a.m. and 5 p.m., Monday through...

  11. HOTEL AND MOTEL HOUSEKEEPING AIDE, A SUGGESTED TRAINING PROGRAM.

    ERIC Educational Resources Information Center

    Office of Education (DHEW), Washington, DC.

    A LOCAL TRAINING PROGRAM TO PREPARE HOTEL AND MOTEL HOUSEKEEPING AIDES CAN BE DEVELOPED FROM RESOURCE MATERIAL IN THIS GUIDE. PROGRAM OBJECTIVES ARE TO PREPARE TRAINEES TO PERFORM THE JOBS INVOLVED IN KEEPING HOTEL OR MOTEL ROOMS CLEAN, TO FOLLOW CORRECT PROCEDURES IN USING EQUIPMENT AND SUPPLIES REQUIRED IN CARING FOR BEDROOMS AND BATHROOMS, AND…

  12. Surgical Theatre (Operating Room) Measure STEEM (OREEM) Scoring Overestimates Educational Environment: The 1-to-L Bias

    ERIC Educational Resources Information Center

    Dimoliatis, Ioannis D. K.; Jelastopulu, Eleni

    2013-01-01

    The surgical theatre educational environment measures STEEM, OREEM and mini-STEEM for students (student-STEEM) comprise an up to now disregarded systematic overestimation (OE) due to inaccurate percentage calculation. The aim of the present study was to investigate the magnitude of and suggest a correction for this systematic bias. After an…

  13. 75 FR 8465 - Airworthiness Directives; McDonnell Douglas Corporation Model MD-90-30 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-25

    ... Administration (FAA), DOT. ACTION: Final rule. SUMMARY: We are adopting a new airworthiness directive (AD) for... frames at stations 883, 902, 924, 943, and 962, left and right sides, and corrective actions if necessary.... Department of Transportation, Docket Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New...

  14. CRDS of 17O enriched water between 5850 and 6671 cm-1: More than 1000 energy levels of H217O and HD17O newly determined

    NASA Astrophysics Data System (ADS)

    Mikhailenko, S. N.; Leshchishina, O.; Karlovets, E. V.; Mondelain, D.; Kassi, S.; Campargue, A.

    2016-07-01

    The room temperature absorption spectrum of water vapor highly enriched in 17O has been recorded by Cavity Ring Down Spectroscopy (CRDS) between 5850 and 6671 cm-1. Two series of recordings were performed with pressure values of 1.0 and 12.0 Torr. The investigated spectral region corresponds to the important 1.55 μm transparency window of the atmosphere where water absorption is very weak. The high sensitivity of the recordings (αmin 5×10-11 cm-1) allows detecting lines with intensity spanning six orders of magnitude (1.4×10-30-3.6×10-24 cm/molecule at room temperature). The experimental list includes more than 10,300 lines. The assignments of water lines were performed using known experimental energy levels as well as calculated line lists based on the results of Partridge and Schwenke. More than 8500 lines were assigned to 9619 transitions of six water isotopologues (H216O, H217O, H218O, HD16O, HD17O and HD18O). All but four transitions of the 16O and 18O isotopologues were assigned using known experimental energy levels. More than half of the assigned H217O and HD17O transitions correspond to new (or corrected) upper energy levels. About 1000 new H217O transitions associated with upper states of the second triad and of the first hexad were identified. Most of the newly assigned HD17O transitions belong to the ν1+ν3 and 2ν2+ν3 bands. The assigned transitions allowed to newly determine or correct 20 highly excited rotational levels of the vibrational ground state of this isotopologue. Overall 791 and 266 energy levels are newly determined for H217O and HD17O, respectively. A few additional levels were corrected compared to literature values. The obtained experimental results are compared to the spectroscopic parameters provided by the HITRAN database and to the empirical energy levels recommended by an IUPAC task group.

  15. Spatiotemporal data visualisation for homecare monitoring of elderly people.

    PubMed

    Juarez, Jose M; Ochotorena, Jose M; Campos, Manuel; Combi, Carlo

    2015-10-01

    Elderly people who live alone can be assisted by home monitoring systems that identify risk scenarios such as falls, fatigue symptoms or burglary. Given that these systems have to manage spatiotemporal data, human intervention is required to validate automatic alarms due to the high number of false positives and the need for context interpretation. The goal of this work was to provide tools to support human action, to identify such potential risk scenarios based on spatiotemporal data visualisation. We propose the MTA (multiple temporal axes) model, a visual representation of temporal information of the activity of a single person at different locations. The main goal of this model is to visualize the behaviour of a person in their home, facilitating the identification of health-risk scenarios and repetitive patterns. We evaluate the model's insight capacity compared with other models using a standard evaluation protocol. We also test its practical suitability of the MTA graphical model in a commercial home monitoring system. In particular, we implemented 8VISU, a visualization tool based on MTA. MTA proved to be more than 90% accurate in identify non-risk scenarios, independently of the length of the record visualised. When the spatial complexity was increased (e.g. number of rooms) the model provided good accuracy form up to 5 rooms. Therefore, user preferences and user performance seem to be balanced. Moreover, it also gave high sensitivity levels (over 90%) for 5-8 rooms. Fall is the most recurrent incident for elderly people. The MTA model outperformed the other models considered in identifying fall scenarios (66% of correctness) and was the second best for burglary and fatigue scenarios (36% of correctness). Our experiments also confirm the hypothesis that cyclic models are the most suitable for fatigue scenarios, the Spiral and MTA models obtaining most positive identifications. In home monitoring systems, spatiotemporal visualization is a useful tool for identifying risk and preventing home accidents in elderly people living alone. The MTA model helps the visualisation in different stages of the temporal data analysis process. In particular, its explicit representation of space and movement is useful for identifying potential scenarios of risk, while the spiral structure can be used for the identification of recurrent patterns. The results of the experiments and the experience using the visualization tool 8VISU proof the potential of the MTA graphical model to mine temporal data and to support caregivers using home monitoring infrastructures. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. 8. VIEW OF SLC3W CONTROL ROOM (ROOM 105) FROM ITS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. VIEW OF SLC-3W CONTROL ROOM (ROOM 105) FROM ITS NORTHEAST CORNER. TELEMETRY ROOM VISIBLE THROUGH WINDOWS IN SOUTH WALL. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  17. 7. VIEW OF SLC3W CONTROL ROOM (ROOM 105) FROM ITS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW OF SLC-3W CONTROL ROOM (ROOM 105) FROM ITS SOUTHWEST CORNER. NOTE RAISED FLATFORM IN CENTER OF ROOM. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. Office-based Relaxing Incision Procedure for Correction of Astigmatism after Deep Anterior Lamellar Keratoplasty

    PubMed Central

    Javadi, Mohammad Ali; Feizi, Sepehr; Mirbabaee, Firooz; Fekri, Yousef

    2017-01-01

    Purpose: To report the outcomes of a simple and effective office-based procedure for the correction of astigmatism after deep anterior lamellar keratoplasty (DALK). Methods: This study enrolled 24 consecutive keratoconic eyes that developed an intolerable amount of graft astigmatism after DALK. The location and extension of steep semi-meridians were determined using corneal topography. Office-based relaxing incision procedures were performed at the slit-lamp biomicroscope using a 27-gauge needle. Relaxing incisions were made at the donor-recipient interface on one side of the steepest meridian with an arc length of 45° to 60° and an initial depth of approximately 70–80% of the corneal thickness. Topography was performed after 30–40 minutes and the initial incision was enhanced in depth and length. If an acceptable amount of astigmatism was not achieved, another incision was created at the opposite semi-meridian during the same session. Results: Mean follow-up period was 13.1 ± 7.4 months. Mean preoperative best spectacle corrected visual acuity was 0.26 ± 0.14 logMAR, increasing to 0.22 ± 0.09 logMAR after the procedure (P = 0.20). Mean spherical equivalent refractive error increased from − 4.64 ± 3.06 diopters (D) preoperatively to −6.06 ± 3.15 D postoperatively (P = 0.01). Mean keratometric astigmatism was reduced by 2.95 ± 3.43 D and 5.16 ± 2.97 D measured using subtraction and vector analysis methods, respectively (P < 0.001). Microperforation occurred in one eye, which spontaneously improved with no sequelae. Conclusion: Office-based relaxing incision is a safe and effective procedure for the treatment of corneal graft astigmatism after DALK. This approach effectively decreases the need for the more costly alternative in the operating room. PMID:28540006

  19. The use of pH adjusted lignocaine in controlling operative pain in the day surgery unit: a prospective, randomised trial.

    PubMed

    Fitton, A R; Ragbir, M; Milling, M A

    1996-09-01

    We report the results of a randomised, case matched, controlled, double blind study on 40 patients undergoing correction of their prominent ears, comparing efficacy of pH adjusted lignocaine to lignocaine alone in controlling operative pain. Each patient received commercial lignocaine in one ear and the same preparation reconstituted with 1 ml of 8.4% sodium bicarbonate in the other ear according to our randomisation protocol. 30 patients were studied to compare the difference between the buffered and commercial preparation infiltrated at room temperature. A further 10 patients were studied to assess the benefit the buffered preparation at room temperature had over commercial lignocaine warmed to body temperature. Linear analogue pain scores for discomfort at infiltration and during the operation itself were analysed. Buffered lignocaine imparts a significant reduction in pain on infiltration, compared to the commercial preparation at both room and body temperature. Both preparations were equally effective in obliterating pain during the operation itself.

  20. Master Console System Monitoring and Control Development

    NASA Technical Reports Server (NTRS)

    Brooks, Russell A.

    2013-01-01

    The Master Console internship during the summer of 2013 involved the development of firing room displays and support applications at the John F. Kennedy Space Center (KSC). This position was with the Master Console Product Group (MCPG) on the Launch Control System (LCS) project. This project is responsible for the System Monitoring and Control (SMC) and Record and Retrieval (R&R) of launch operations data. The Master Console is responsible for: loading the correct software into each of the remaining consoles in the firing room, connecting the proper data paths to and from the launch vehicle and all ground support equipment, and initializing the entire firing room system to begin processing. During my internship, I created control scripts using the Application Control Language (ACL) to analyze the health and status of Kennedy Ground Control System (KGCS) programmable logic controllers (PLCs). This application provides a system health and status display I created with summarized data for use by Master Console Operators (MCO) to monitor and verify the integrity of KGCS subsystems.

  1. Attention promotes episodic encoding by stabilizing hippocampal representations

    PubMed Central

    Aly, Mariam; Turk-Browne, Nicholas B.

    2016-01-01

    Attention influences what is later remembered, but little is known about how this occurs in the brain. We hypothesized that behavioral goals modulate the attentional state of the hippocampus to prioritize goal-relevant aspects of experience for encoding. Participants viewed rooms with paintings, attending to room layouts or painting styles on different trials during high-resolution functional MRI. We identified template activity patterns in each hippocampal subfield that corresponded to the attentional state induced by each task. Participants then incidentally encoded new rooms with art while attending to the layout or painting style, and memory was subsequently tested. We found that when task-relevant information was better remembered, the hippocampus was more likely to have been in the correct attentional state during encoding. This effect was specific to the hippocampus, and not found in medial temporal lobe cortex, category-selective areas of the visual system, or elsewhere in the brain. These findings provide mechanistic insight into how attention transforms percepts into memories. PMID:26755611

  2. Suspected leaking abdominal aortic aneurysm: use of sonography in the emergency room.

    PubMed

    Shuman, W P; Hastrup, W; Kohler, T R; Nyberg, D A; Wang, K Y; Vincent, L M; Mack, L A

    1988-07-01

    To determine the value of sonography in the emergent evaluation of suspected leaking abdominal aortic aneurysms, the authors examined 60 patients in the emergency department using sonography and a protocol involving advance radio notification from the ambulance; arrival of sonographic personnel and equipment in the triage room before patient arrival; and, during other triage activities, rapid sonographic evaluation of the aorta for aneurysm and of the paraaortic region for extraluminal blood. Sonographic findings were correlated with surgical results and clinical outcome. When performed under these circumstances, sonography was accurate in demonstrating presence or absence of aneurysm (98%), but its sensitivity for extraluminal blood was poor (4%). A combination of sonographic confirmation of aneurysm, abdominal pain, and unstable hemodynamic condition resulted in the correct decision to perform emergent surgery in 21 of 22 patients (95%). An abbreviated sonographic examination done in the emergency room can provide accurate, useful information about the presence of aneurysm; this procedure does not significantly delay triage of these patients.

  3. Investigating Perceived vs. Medical Weight Status Classification among College Students: Room for Improvement Exists among the Overweight and Obese

    ERIC Educational Resources Information Center

    Duffrin, Christopher; Eakin, Angela; Bertrand, Brenda; Barber-Heidel, Kimberly; Carraway-Stage, Virginia

    2011-01-01

    The American College Health Association estimated that 31% of college students are overweight or obese. It is important that students have a correct perception of body weight status as extra weight has potential adverse health effects. This study assessed accuracy of perceived weight status versus medical classification among 102 college students.…

  4. The Development of a Token Reinforcement System for a Specific Lesson. Technical Report #11.

    ERIC Educational Resources Information Center

    Au, Kathryn

    This paper presents a brief description of a token reinforcement system developed for a kindergarten language class in the Kamehameha Early Education Program (KEEP). Visual reinforcers (colored plastic tabs) were placed next to the names of individual children (each time they made a correct response) on a large chart in the front of the room. Five…

  5. High-quality remote interactive imaging in the operating theatre

    NASA Astrophysics Data System (ADS)

    Grimstead, Ian J.; Avis, Nick J.; Evans, Peter L.; Bocca, Alan

    2009-02-01

    We present a high-quality display system that enables the remote access within an operating theatre of high-end medical imaging and surgical planning software. Currently, surgeons often use printouts from such software for reference during surgery; our system enables surgeons to access and review patient data in a sterile environment, viewing real-time renderings of MRI & CT data as required. Once calibrated, our system displays shades of grey in Operating Room lighting conditions (removing any gamma correction artefacts). Our system does not require any expensive display hardware, is unobtrusive to the remote workstation and works with any application without requiring additional software licenses. To extend the native 256 levels of grey supported by a standard LCD monitor, we have used the concept of "PseudoGrey" where slightly off-white shades of grey are used to extend the intensity range from 256 to 1,785 shades of grey. Remote access is facilitated by a customized version of UltraVNC, which corrects remote shades of grey for display in the Operating Room. The system is successfully deployed at Morriston Hospital, Swansea, UK, and is in daily use during Maxillofacial surgery. More formal user trials and quantitative assessments are being planned for the future.

  6. Evaluation of noise pollution level in the operating rooms of hospitals: A study in Iran.

    PubMed

    Giv, Masoumeh Dorri; Sani, Karim Ghazikhanlou; Alizadeh, Majid; Valinejadi, Ali; Majdabadi, Hesamedin Askari

    2017-06-01

    Noise pollution in the operating rooms is one of the remaining challenges. Both patients and physicians are exposed to different sound levels during the operative cases, many of which can last for hours. This study aims to evaluate the noise pollution in the operating rooms during different surgical procedures. In this cross-sectional study, sound level in the operating rooms of Hamadan University-affiliated hospitals (totally 10) in Iran during different surgical procedures was measured using B&K sound meter. The gathered data were compared with national and international standards. Statistical analysis was performed using descriptive statistics and one-way ANOVA, t -test, and Pearson's correlation test. Noise pollution level at majority of surgical procedures is higher than national and international documented standards. The highest level of noise pollution is related to orthopedic procedures, and the lowest one related to laparoscopic and heart surgery procedures. The highest and lowest registered sound level during the operation was 93 and 55 dB, respectively. Sound level generated by equipments (69 ± 4.1 dB), trolley movement (66 ± 2.3 dB), and personnel conversations (64 ± 3.9 dB) are the main sources of noise. The noise pollution of operating rooms are higher than available standards. The procedure needs to be corrected for achieving the proper conditions.

  7. Control of the Environment in the Operating Room.

    PubMed

    Katz, Jonathan D

    2017-10-01

    There is a direct relationship between the quality of the environment of a workplace and the productivity and efficiency of the work accomplished. Components such as temperature, humidity, ventilation, drafts, lighting, and noise each contribute to the quality of the overall environment and the sense of well-being of those who work there.The modern operating room is a unique workplace with specific, and frequently conflicting, environmental requirements for each of the inhabitants. Even minor disturbances in the internal environment of the operating room can have serious ramifications on the comfort, effectiveness, and safety of each of the inhabitants. A cool, well-ventilated, and dry climate is optimal for many members of the surgical team. Any significant deviation from these objectives raises the risk of decreased efficiency and productivity and adverse surgical outcomes. A warmer, more humid, and quieter environment is necessary for the patient. If these requirements are not met, the risk of surgical morbidity and mortality is increased. An important task for the surgical team is to find the correct balance between these 2 opposed requirements. Several of the components of the operating room environment, especially room temperature and airflow patterns, are easily manipulated by the members of the surgical team. In the following discussion, we will examine these elements to better understand the clinical ramifications of adjustments and accommodations that are frequently made to meet the requirements of both the surgical staff and the patient.

  8. Methods for intraoperative, sterile pose-setting of patient-specific microstereotactic frames

    NASA Astrophysics Data System (ADS)

    Vollmann, Benjamin; Müller, Samuel; Kundrat, Dennis; Ortmaier, Tobias; Kahrs, Lüder A.

    2015-03-01

    This work proposes new methods for a microstereotactic frame based on bone cement fixation. Microstereotactic frames are under investigation for minimal invasive temporal bone surgery, e.g. cochlear implantation, or for deep brain stimulation, where products are already on the market. The correct pose of the microstereotactic frame is either adjusted outside or inside the operating room and the frame is used for e.g. drill or electrode guidance. We present a patientspecific, disposable frame that allows intraoperative, sterile pose-setting. Key idea of our approach is bone cement between two plates that cures while the plates are positioned with a mechatronics system in the desired pose. This paper includes new designs of microstereotactic frames, a system for alignment and first measurements to analyze accuracy and applicable load.

  9. 54. Room BF14, IDA room, basement level, building 500, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    54. Room BF-14, IDA room, basement level, building 500, looking west - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  10. Use of RBC-O and S-MCV parameters of SYSMEX XE-2100 in a patient with RBC cold agglutination.

    PubMed

    Wang, Hong; Lu, Lin; Zhou, Yun; Liu, Jian; Qian, Min; Tang, Weiming; Jie, Zhang; Pan, Shiyang

    2013-01-01

    Sometimes EDTA blood of erythrocyte agglutination cannot be well resolved by incubation at 37 degrees C. In this case report, however, such a specimen was detected from a lymphoma patient at room temperature by using RBC-O and S-MCV parameters of the SYSMEX XE-2100 hematology analyzer. The specimen was diluted with 0.9% NaCL solution at 1:1 before measurement. HCT, MCV, and MCHC, corrected by RBC-O, HGB and S-MCV, were all in their normal ranges. This case indicates that RBC-O and S-MCV parameters of XE-2100 can be used in the routine blood examination of erythrocyte agglutination specimen at room temperature.

  11. 12. "TAPE ROOM" LOCATED AT SOUTHEAST CORNER OF MAIN ROOM. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. "TAPE ROOM" LOCATED AT SOUTHEAST CORNER OF MAIN ROOM. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  12. 6. VIEW OF SLC3W CONTROL ROOM (ROOM 105) FROM ITS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW OF SLC-3W CONTROL ROOM (ROOM 105) FROM ITS SOUTHEAST CORNER - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  13. 8. VIEW OF ROOM 101 (ASSEMBLY ROOM) FROM NORTHEAST CORNER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. VIEW OF ROOM 101 (ASSEMBLY ROOM) FROM NORTHEAST CORNER SHOWING FLEXIBLE AIR-CONDITIONING DUCT - Vandenberg Air Force Base, Space Launch Complex 3, Vehicle Support Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  14. 17. Interior view of vestibule separating locker rooms, changing rooms ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Interior view of vestibule separating locker rooms, changing rooms and restroom beyond; southwest corner of unoccupied portion; view to northwest. - Ellsworth Air Force Base, Mess & Administration Building, 2279 Risner Drive, Blackhawk, Meade County, SD

  15. Initial clinical experience with a video-based patient positioning system.

    PubMed

    Johnson, L S; Milliken, B D; Hadley, S W; Pelizzari, C A; Haraf, D J; Chen, G T

    1999-08-01

    To report initial clinical experience with an interactive, video-based patient positioning system that is inexpensive, quick, accurate, and easy to use. System hardware includes two black-and-white CCD cameras, zoom lenses, and a PC equipped with a frame grabber. Custom software is used to acquire and archive video images, as well as to display real-time subtraction images revealing patient misalignment in multiple views. Two studies are described. In the first study, video is used to document the daily setup histories of 5 head and neck patients. Time-lapse cine loops are generated for each patient and used to diagnose and correct common setup errors. In the second study, 6 twice-daily (BID) head and neck patients are positioned according to the following protocol: at AM setups conventional treatment room lasers are used; at PM setups lasers are used initially and then video is used for 1-2 minutes to fine-tune the patient position. Lateral video images and lateral verification films are registered off-line to compare the distribution of setup errors per patient, with and without video assistance. In the first study, video images were used to determine the accuracy of our conventional head and neck setup technique, i.e., alignment of lightcast marks and surface anatomy to treatment room lasers and the light field. For this initial cohort of patients, errors ranged from sigma = 5 to 7 mm and were patient-specific. Time-lapse cine loops of the images revealed sources of the error, and as a result, our localization techniques and immobilization device were modified to improve setup accuracy. After the improvements, conventional setup errors were reduced to sigma = 3 to 5 mm. In the second study, when a stereo pair of live subtraction images were introduced to perform daily "on-line" setup correction, errors were reduced to sigma = 1 to 3 mm. Results depended on patient health and cooperation and the length of time spent fine-tuning the position. An interactive, video-based patient positioning system was shown to reduce setup errors to within 1 to 3 mm in head and neck patients, without a significant increase in overall treatment time or labor-intensive procedures. Unlike retrospective portal image analysis, use of two live-video images provides the therapists with immediate feedback and allows for true 3-D positioning and correction of out-of-plane rotation before radiation is delivered. With significant improvement in head and neck alignment and the elimination of setup errors greater than 3 to 5 mm, margins associated with treatment volumes potentially can be reduced, thereby decreasing normal tissue irradiation.

  16. Requirements for the design and implementation of checklists for surgical processes.

    PubMed

    Verdaasdonk, E G G; Stassen, L P S; Widhiasmara, P P; Dankelman, J

    2009-04-01

    The use of checklists is a promising strategy for improving patient safety in all types of surgical processes inside and outside the operating room. This article aims to provide requirements and implementation of checklists for surgical processes. The literature on checklist use in the operating room was reviewed based on research using Medline, Pubmed, and Google Scholar. Although all the studies showed positive effects and important benefits such as improved team cohesion, improved awareness of safety issues, and reduction of errors, their number still is limited. The motivation of team members is considered essential for compliance. Currently, no general guidelines exist for checklist design in the surgical field. Based on the authors' experiences and on guidelines used in the aviation industry, requirements for the checklist design are proposed. The design depends on the checklist purpose, philosophy, and method chosen. The methods consist of the "call-do-response" approach," the "do-verify" approach, or a combination of both. The advantages and disadvantages of paper versus electronic solutions are discussed. Furthermore, a step-by-step strategy of how to implement a checklist in the clinical situation is suggested. The use of structured checklists in surgical processes is most likely to be effective because it standardizes human performance and ensures that procedures are followed correctly instead of relying on human memory alone. Several studies present promising and positive first results, providing a solid basis for further investigation. Future research should focus on the effect of various checklist designs and strategies to ensure maximal compliance.

  17. Evaluating the effect of distractions in the operating room on clinical decision-making and patient safety.

    PubMed

    Murji, Ally; Luketic, Lea; Sobel, Mara L; Kulasegaram, Kulamakan Mahan; Leyland, Nicholas; Posner, Glenn

    2016-10-01

    Answering telephone calls and pagers is common distraction in the operating room. We sought to evaluate the impact of distractions on patient care by (1) assessing the accuracy and safety of responses to clinical questions posed to a surgeon while operating and (2) determining whether pager distractions affect simulation-based surgical performance. We conducted a randomized crossover study of obstetrics and gynecology residents. After studying a patient sign-out list, subjects performed a virtual salpingectomy. They were randomized to a distraction phase followed by quiet phase or vice versa. In the distraction phase, a pager beeped and subjects were asked questions based on the sign-out list. Accuracy of responses and the number of unsafe responses were recorded. In the quiet phase, trainees performed the task uninterrupted. Measures of surgical performance were successful task completion, time to task completion and operative blood loss. The mean score for correct responses to clinical questions during the distracted phase was 80 % (SD ±14 %). Nineteen residents (63 %) made at least 1 unsafe clinical decision while operating on the simulator (range 0-3). Subjects were more likely to successfully complete the surgical task in the allotted time under the quiet compared to distraction condition (OR 11.3, p = 0.03). There was no difference between the conditions in paired analysis for mean time (seconds) to task completion [426 (SD 133) vs. 440 (SD 186), p = 0.61] and mean operative blood loss (mL) [73.14 (SD 106) vs. 112.70 (SD 358), p = 0.47]. Distractions in the operating room may have a profound impact on patient safety on the wards. While multitasking in a simulated setting, the majority of residents made at least one unsafe clinical decision. Pager distractions also hindered surgical residents' ability to complete a simulated laparoscopic task in the allotted time without affecting other variables of surgical performance.

  18. Requirements for the structured recording of surgical device data in the digital operating room.

    PubMed

    Rockstroh, Max; Franke, Stefan; Neumuth, Thomas

    2014-01-01

    Due to the increasing complexity of the surgical working environment, increasingly technical solutions must be found to help relieve the surgeon. This objective is supported by a structured storage concept for all relevant device data. In this work, we present a concept and prototype development of a storage system to address intraoperative medical data. The requirements of such a system are described, and solutions for data transfer, processing, and storage are presented. In a subsequent study, a prototype based on the presented concept is tested for correct and complete data transmission and storage and for the ability to record a complete neurosurgical intervention with low processing latencies. In the final section, several applications for the presented data recorder are shown. The developed system based on the presented concept is able to store the generated data correctly, completely, and quickly enough even if much more data than expected are sent during a surgical intervention. The Surgical Data Recorder supports automatic recognition of the interventional situation by providing a centralized data storage and access interface to the OR communication bus. In the future, further data acquisition technologies should be integrated. Therefore, additional interfaces must be developed. The data generated by these devices and technologies should also be stored in or referenced by the Surgical Data Recorder to support the analysis of the OR situation.

  19. Development of a golden beam data set for the commissioning of a proton double-scattering system in a pencil-beam dose calculation algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slopsema, R. L., E-mail: rslopsema@floridaproton.org; Flampouri, S.; Yeung, D.

    2014-09-15

    Purpose: The purpose of this investigation is to determine if a single set of beam data, described by a minimal set of equations and fitting variables, can be used to commission different installations of a proton double-scattering system in a commercial pencil-beam dose calculation algorithm. Methods: The beam model parameters required to commission the pencil-beam dose calculation algorithm (virtual and effective SAD, effective source size, and pristine-peak energy spread) are determined for a commercial double-scattering system. These parameters are measured in a first room and parameterized as function of proton energy and nozzle settings by fitting four analytical equations tomore » the measured data. The combination of these equations and fitting values constitutes the golden beam data (GBD). To determine the variation in dose delivery between installations, the same dosimetric properties are measured in two additional rooms at the same facility, as well as in a single room at another facility. The difference between the room-specific measurements and the GBD is evaluated against tolerances that guarantee the 3D dose distribution in each of the rooms matches the GBD-based dose distribution within clinically reasonable limits. The pencil-beam treatment-planning algorithm is commissioned with the GBD. The three-dimensional dose distribution in water is evaluated in the four treatment rooms and compared to the treatment-planning calculated dose distribution. Results: The virtual and effective SAD measurements fall between 226 and 257 cm. The effective source size varies between 2.4 and 6.2 cm for the large-field options, and 1.0 and 2.0 cm for the small-field options. The pristine-peak energy spread decreases from 1.05% at the lowest range to 0.6% at the highest. The virtual SAD as well as the effective source size can be accurately described by a linear relationship as function of the inverse of the residual energy. An additional linear correction term as function of RM-step thickness is required for accurate parameterization of the effective SAD. The GBD energy spread is given by a linear function of the exponential of the beam energy. Except for a few outliers, the measured parameters match the GBD within the specified tolerances in all of the four rooms investigated. For a SOBP field with a range of 15 g/cm{sup 2} and an air gap of 25 cm, the maximum difference in the 80%–20% lateral penumbra between the GBD-commissioned treatment-planning system and measurements in any of the four rooms is 0.5 mm. Conclusions: The beam model parameters of the double-scattering system can be parameterized with a limited set of equations and parameters. This GBD closely matches the measured dosimetric properties in four different rooms.« less

  20. Annoyance caused by propeller airplane flyover noise

    NASA Technical Reports Server (NTRS)

    Mccurdy, D. A.; Powell, C. A.

    1984-01-01

    Laboratory experiments were conducted to provide information on quantifying the annoyance response of people to propeller airplane noise. The items of interest were current noise metrics, tone corrections, duration corrections, critical band corrections, and the effects of engine type, operation type, maximum takeoff weight, blade passage frequency, and blade tip speed. In each experiment, 64 subjects judged the annoyance of recordings of propeller and jet airplane operations presented at d-weighted sound pressure levels of 70, 80, and 90 dB in a testing room which simulates the outdoor acoustic environment. The first experiment examined 11 propeller airplanes with maximum takeoff weights greater than or equal to 5700 kg. The second experiment examined 14 propeller airplanes weighting 5700 kg or less. Five jet airplanes were included in each experiment. For both the heavy and light propeller airplanes, perceived noise level and perceived level (Stevens Mark VII procedure) predicted annoyance better than other current noise metrics.

  1. Recovery and radiation corrections and time constants of several sizes of shielded and unshielded thermocouple probes for measuring gas temperature

    NASA Technical Reports Server (NTRS)

    Glawe, G. E.; Holanda, R.; Krause, L. N.

    1978-01-01

    Performance characteristics were experimentally determined for several sizes of a shielded and unshielded thermocouple probe design. The probes are of swaged construction and were made of type K wire with a stainless steel sheath and shield and MgO insulation. The wire sizes ranged from 0.03- to 1.02-mm diameter for the unshielded design and from 0.16- to 0.81-mm diameter for the shielded design. The probes were tested through a Mach number range of 0.2 to 0.9, through a temperature range of room ambient to 1420 K, and through a total-pressure range of 0.03 to 0.2.2 MPa (0.3 to 22 atm). Tables and graphs are presented to aid in selecting a particular type and size. Recovery corrections, radiation corrections, and time constants were determined.

  2. An extensive review of commercial product labels the good, bad and ugly.

    PubMed

    Mrvos, R; Dean, B S; Krenzelok, E P

    1986-02-01

    Cautions and warnings on consumer products play an important role in the prevention and treatment of poison exposures. Frequently those exposed will follow the directions before calling the poison center, physician or emergency room. An extensive label review of 200 commercial products was conducted to determine if medical treatment advice was correct, if the general public was able to comprehend warning statements, and if warnings were adequate. We conclude there are products available that provide precise, correct information. However, there are many that contain incorrect, misleading, and often dangerous information to an unsuspecting public. Various examples of both types are given to make the poison information specialist aware of what information is presented.

  3. Label Design Affects Medication Safety in an Operating Room Crisis: A Controlled Simulation Study.

    PubMed

    Estock, Jamie L; Murray, Andrew W; Mizah, Margaret T; Mangione, Michael P; Goode, Joseph S; Eibling, David E

    2018-06-01

    Several factors contribute to medication errors in clinical practice settings, including the design of medication labels. The objective of this study was to quantify the impact of label design on medication safety in a realistic, high-stress clinical situation. Ninety-six anesthesia trainee participants were randomly assigned to either the redesigned or the current label condition. Participants were blinded to the study's focus on medication label design and their assigned label condition. Each participant was the sole anesthesia provider in a simulated operating room scenario involving an unexpected vascular injury. The surgeon asked the participant to administer hetastarch to the simulated patient because of hemodynamic instability. The fluid drawer of the anesthesia cart contained three 500-ml intravenous bags of hetastarch and one 500-ml intravenous bag of lidocaine. We hypothesized that redesigned labels would help participants correctly select hetastarch from the cart. If the participants incorrectly selected lidocaine from the cart, we hypothesized that the redesigned labels would help participants detect the lidocaine before administration. The percentage of participants who correctly selected hetastarch from the cart was significantly higher for the redesigned labels than the current labels (63% versus 40%; odds ratio, 2.61 [95% confidence interval, 1.1-6.1]; P = 0.03). Of the participants who incorrectly selected lidocaine from the cart, the percentage who detected the lidocaine before administration did not differ by label condition. The redesigned labels helped participants correctly select hetastarch from the cart, thus preventing some potentially catastrophic medication errors from reaching the simulated patient.

  4. The operating room of the future: observations and commentary.

    PubMed

    Satava, Richard M

    2003-09-01

    The Operating Room of the Future is a construct upon which to develop the next generation of operating environments for the patient, surgeon, and operating team. Analysis of the suite of visions for the Operating Room of the Future reveals a broad set of goals, with a clear overall solution to create a safe environment for high-quality healthcare. The vision, although planned for the future, is based upon iteratively improving and integrating current systems, both technology and process. This must become the Operating Room of Today, which will require the enormous efforts described. An alternative future of the operating room, based upon emergence of disruptive technologies, is also presented.

  5. Passive ultra-brief video training improves performance of compression-only cardiopulmonary resuscitation.

    PubMed

    Benoit, Justin L; Vogele, Jennifer; Hart, Kimberly W; Lindsell, Christopher J; McMullan, Jason T

    2017-06-01

    Bystander compression-only cardiopulmonary resuscitation (CPR) improves survival after out-of-hospital cardiac arrest. To broaden CPR training, 1-2min ultra-brief videos have been disseminated via the Internet and television. Our objective was to determine whether participants passively exposed to a televised ultra-brief video perform CPR better than unexposed controls. This before-and-after study was conducted with non-patients in an urban Emergency Department waiting room. The intervention was an ultra-brief CPR training video displayed via closed-circuit television 3-6 times/hour. Participants were unaware of the study and not told to watch the video. Pre-intervention, no video was displayed. Participants were asked to demonstrate compression-only CPR on a manikin. Performance was scored based on critical actions: check for responsiveness, call for help, begin compressions immediately, and correct hand placement, compression rate and depth. The primary outcome was the proportion of participants who performed all actions correctly. There were 50 control and 50 exposed participants. Mean age was 37, 51% were African-American, 52% were female, and 10% self-reported current CPR certification. There were no statistically significant differences in baseline characteristics between groups. The number of participants who performed all actions correctly was 0 (0%) control vs. 10 (20%) exposed (difference 20%, 95% confidence interval [CI] 8.9-31.1%, p<0.001). Correct compression rate and depth were 11 (22%) control vs. 22 (44%) exposed (22%, 95% CI 4.1-39.9%, p=0.019), and 5 (10%) control vs. 15 (30%) exposed (20%, 95% CI 4.8-35.2%, p=0.012), respectively. Passive ultra-brief video training is associated with improved performance of compression-only CPR. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Size-controllable APTS stabilized ruthenium(0) nanoparticles catalyst for the dehydrogenation of dimethylamine-borane at room temperature.

    PubMed

    Zahmakıran, Mehmet; Philippot, Karine; Özkar, Saim; Chaudret, Bruno

    2012-01-14

    Dimethylamine-borane, (CH(3))(2)NHBH(3), has been considered as one of the attractive materials for the efficient storage of hydrogen, which is still one of the key issues in the "Hydrogen Economy". In a recent communication we have reported the synthesis and characterization of 3-aminopropyltriethoxysilane stabilized ruthenium(0) nanoparticles with the preliminary results for their catalytic performance in the dehydrogenation of dimethylamine-borane at room temperature. Herein, we report a complete work including (i) effect of initial [APTS]/[Ru] molar ratio on both the size and the catalytic activity of ruthenium(0) nanoparticles, (ii) collection of extensive kinetic data under non-MTL conditions depending on the substrate and catalyst concentrations to define the rate law of Ru(0)/APTS-catalyzed dehydrogenation of dimethylamine-borane at room temperature, (iii) determination of activation parameters (E(a), ΔH(#) and ΔS(#)) for Ru(0)/APTS-catalyzed dehydrogenation of dimethylamine-borane; (iv) demonstration of the catalytic lifetime of Ru(0)/APTS nanoparticles in the dehydrogenation of dimethylamine-borane at room temperature, (v) testing the bottlability and reusability of Ru(0)/APTS nanocatalyst in the room-temperature dehydrogenation of dimethylamine-borane, (vi) quantitative carbon disulfide (CS(2)) poisoning experiments to find a corrected TTO and TOF values on a per-active-ruthenium-atom basis, (vii) a summary of extensive literature review for the catalysts tested in the catalytic dehydrogenation of dimethylamine-borane as part of the results and discussions.

  7. Fashion versus perception: the impact of surface lightness on the perceived dimensions of interior space.

    PubMed

    Oberfeld, Daniel; Hecht, Heiko

    2011-06-01

    We compare expert opinion with perceptual judgment regarding the influence of color on the perceived height and width of interior rooms. We hypothesize that contrary to popular belief, ceiling and wall lightness have additive effects on perceived height, whereas the lightness contrast between these surfaces is less important. We assessed the intuitions of architectural experts as to which surface colors maximize apparent height and compared these intuitions with psychophysical height and width estimates for rooms differing in ceiling, floor, and wall lightness. Experiment 1 was a survey of architectural experts and nonexperts. Experiments 2 and 3 presented virtual rooms varying in physical height, physical width, and surface lightness. In Experiment 1, both experts and nonexperts erroneously assumed that the lightness contrast between ceiling and walls influences perceived height Experiment 2 showed that the lightness contrast does not determine apparent height but that ceiling and wall lightness have additive effects. Experiment 3 demonstrated a decrease in perceived width with physical height, whereas the perceived height was not related to physical width. Apparent width was unaffected by ceiling lightness. Light ceiling and light walls make a room appear higher, whereas floor color has a weaker effect. We also found evidence for an asymmetric interaction between height and width. The question of how to color walls and ceiling to maximize the apparent size of a room can be answered empirically. Aesthetic considerations may interfere with the correct assessment of the effects of color in experts.

  8. Impact of a primary care based intervention on breast cancer knowledge, risk perception and concern: A randomized, controlled trial

    PubMed Central

    Livaudais-Toman, Jennifer; Karliner, Leah S.; Tice, Jeffrey A.; Kerlikowske, Karla; Gregorich, Steven; Pérez-Stable, Eliseo J.; Pasick, Rena J.; Chen, Alice; Quinn, Jessica; Kaplan, Celia P.

    2015-01-01

    Purpose To estimate the effects of a tablet-based, breast cancer risk education intervention for use in primary care settings (BreastCARE) on patients' breast cancer knowledge, risk perception and concern. Methods From June 2011–August 2012, we enrolled women from two clinics, aged 40–74 years with no personal breast cancer history, and randomized them to the BreastCARE intervention group or to the control group. All patients completed a baseline telephone survey and risk assessment (via telephone for controls, via tablet computer in clinic waiting room prior to visit for intervention). All women were categorized as high or average risk based on the Referral Screening Tool, the Gail model or the Breast Cancer Surveillance Consortium model. Intervention patients and their physicians received an individualized risk report to discuss during the visit. All women completed a follow-up telephone survey 1–2 weeks after risk assessment. Post-test comparisons estimated differences at follow-up in breast cancer knowledge, risk perception and concern. Results 580 intervention and 655 control women completed follow-up interviews. Mean age was 56 years (SD = 9). At follow-up, 73% of controls and 71% of intervention women correctly perceived their breast cancer risk and 22% of controls and 24% of intervention women were very concerned about breast cancer. Intervention patients had greater knowledge (≥75% correct answers) of breast cancer risk factors at follow-up (24% vs. 16%; p = 0.002). In multivariable analysis, there were no differences in correct risk perception or concern, but intervention patients had greater knowledge ([OR] = 1.62; 95% [CI] = 1.19–2.23). Conclusions A simple, practical intervention involving physicians at the point of care can improve knowledge of breast cancer without increasing concern. Trial Registration ClinicalTrials.gov identifier NCT01830933. PMID:26476466

  9. Impact of a primary care based intervention on breast cancer knowledge, risk perception and concern: A randomized, controlled trial.

    PubMed

    Livaudais-Toman, Jennifer; Karliner, Leah S; Tice, Jeffrey A; Kerlikowske, Karla; Gregorich, Steven; Pérez-Stable, Eliseo J; Pasick, Rena J; Chen, Alice; Quinn, Jessica; Kaplan, Celia P

    2015-12-01

    To estimate the effects of a tablet-based, breast cancer risk education intervention for use in primary care settings (BreastCARE) on patients' breast cancer knowledge, risk perception and concern. From June 2011-August 2012, we enrolled women from two clinics, aged 40-74 years with no personal breast cancer history, and randomized them to the BreastCARE intervention group or to the control group. All patients completed a baseline telephone survey and risk assessment (via telephone for controls, via tablet computer in clinic waiting room prior to visit for intervention). All women were categorized as high or average risk based on the Referral Screening Tool, the Gail model or the Breast Cancer Surveillance Consortium model. Intervention patients and their physicians received an individualized risk report to discuss during the visit. All women completed a follow-up telephone survey 1-2 weeks after risk assessment. Post-test comparisons estimated differences at follow-up in breast cancer knowledge, risk perception and concern. 580 intervention and 655 control women completed follow-up interviews. Mean age was 56 years (SD = 9). At follow-up, 73% of controls and 71% of intervention women correctly perceived their breast cancer risk and 22% of controls and 24% of intervention women were very concerned about breast cancer. Intervention patients had greater knowledge (≥75% correct answers) of breast cancer risk factors at follow-up (24% vs. 16%; p = 0.002). In multivariable analysis, there were no differences in correct risk perception or concern, but intervention patients had greater knowledge ([OR] = 1.62; 95% [CI] = 1.19-2.23). A simple, practical intervention involving physicians at the point of care can improve knowledge of breast cancer without increasing concern. ClinicalTrials.gov identifier NCT01830933. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Graphene-based room-temperature implementation of a modified Deutsch-Jozsa quantum algorithm.

    PubMed

    Dragoman, Daniela; Dragoman, Mircea

    2015-12-04

    We present an implementation of a one-qubit and two-qubit modified Deutsch-Jozsa quantum algorithm based on graphene ballistic devices working at room temperature. The modified Deutsch-Jozsa algorithm decides whether a function, equivalent to the effect of an energy potential distribution on the wave function of ballistic charge carriers, is constant or not, without measuring the output wave function. The function need not be Boolean. Simulations confirm that the algorithm works properly, opening the way toward quantum computing at room temperature based on the same clean-room technologies as those used for fabrication of very-large-scale integrated circuits.

  11. Alcohol based surgical prep solution and the risk of fire in the operating room: a case report

    PubMed Central

    Batra, Sumit; Gupta, Rajiv

    2008-01-01

    A few cases of fire in the operating room are reported in the literature. The factors that may initiate these fires are many and include alcohol based surgical prep solutions, electrosurgical equipment, flammable drapes etc. We are reporting a case of fire in the operating room while operating on a patient with burst fracture C6 vertebra with quadriplegia. The cause of the fire was due to incomplete drying of the covering drapes with an alcohol based surgical prep solution. This paper discusses potential preventive measures to minimize the incidence of fire in the operating room. PMID:18439304

  12. Use of an acoustic helium analyzer for measuring lung volumes.

    PubMed

    Krumpe, P E; MacDannald, H J; Finley, T N; Schear, H E; Hall, J; Cribbs, D

    1981-01-01

    We have evaluated the use of an acoustic gas analyzer (AGA) for the measurement of total lung capacity (TLC) by single-breath helium dilution. The AGA has a rapid response time (0-90% response = 160 ms for 10% He), is linear for helium concentration of 0.1-10%, is stable over a wide range of ambient temperatures, and is small and portable. We plotted the output of the AGA vs. expired lung volume after a vital capacity breath of 10% He. However, since the AGA is sensitive to changes in speed of sound relative to air, the AGA output signal also reports an artifact due to alveolar gases. We corrected for this artifact by replotting a single-breath expiration after a vital capacity breath of room air. Mean alveolar helium concentration (HeA) was then measured by planimetry, using this alveolar gas curve as the base line. TLC was calculated using the HeA from the corrected AGA output and compared with TLC calculated from HeA simultaneously measured using a mass spectrometer (MS). In 12 normal subjects and 9 patients with chronic obstructive pulmonary disease (COPD) TLC-AGA and TLC-MS were compared by linear regression analysis; correlation coefficient (r) was 0.973 for normals and 0.968 for COPD patients (P less than 0.001). This single-breath; estimation of TLC using the corrected signal of the AGA vs. Expired volume seems ideally suited for the measurement of subdivisions of lung volume in field studies.

  13. Room temperature organic magnets derived from sp3 functionalized graphene.

    PubMed

    Tuček, Jiří; Holá, Kateřina; Bourlinos, Athanasios B; Błoński, Piotr; Bakandritsos, Aristides; Ugolotti, Juri; Dubecký, Matúš; Karlický, František; Ranc, Václav; Čépe, Klára; Otyepka, Michal; Zbořil, Radek

    2017-02-20

    Materials based on metallic elements that have d orbitals and exhibit room temperature magnetism have been known for centuries and applied in a huge range of technologies. Development of room temperature carbon magnets containing exclusively sp orbitals is viewed as great challenge in chemistry, physics, spintronics and materials science. Here we describe a series of room temperature organic magnets prepared by a simple and controllable route based on the substitution of fluorine atoms in fluorographene with hydroxyl groups. Depending on the chemical composition (an F/OH ratio) and sp 3 coverage, these new graphene derivatives show room temperature antiferromagnetic ordering, which has never been observed for any sp-based materials. Such 2D magnets undergo a transition to a ferromagnetic state at low temperatures, showing an extraordinarily high magnetic moment. The developed theoretical model addresses the origin of the room temperature magnetism in terms of sp 2 -conjugated diradical motifs embedded in an sp 3 matrix and superexchange interactions via -OH functionalization.

  14. Room temperature organic magnets derived from sp3 functionalized graphene

    PubMed Central

    Tuček, Jiří; Holá, Kateřina; Bourlinos, Athanasios B.; Błoński, Piotr; Bakandritsos, Aristides; Ugolotti, Juri; Dubecký, Matúš; Karlický, František; Ranc, Václav; Čépe, Klára; Otyepka, Michal; Zbořil, Radek

    2017-01-01

    Materials based on metallic elements that have d orbitals and exhibit room temperature magnetism have been known for centuries and applied in a huge range of technologies. Development of room temperature carbon magnets containing exclusively sp orbitals is viewed as great challenge in chemistry, physics, spintronics and materials science. Here we describe a series of room temperature organic magnets prepared by a simple and controllable route based on the substitution of fluorine atoms in fluorographene with hydroxyl groups. Depending on the chemical composition (an F/OH ratio) and sp3 coverage, these new graphene derivatives show room temperature antiferromagnetic ordering, which has never been observed for any sp-based materials. Such 2D magnets undergo a transition to a ferromagnetic state at low temperatures, showing an extraordinarily high magnetic moment. The developed theoretical model addresses the origin of the room temperature magnetism in terms of sp2-conjugated diradical motifs embedded in an sp3 matrix and superexchange interactions via –OH functionalization. PMID:28216636

  15. 10. CONTROL ROOM INTERIOR. Looking into southwest corner. CONTROL ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. CONTROL ROOM INTERIOR. Looking into southwest corner. CONTROL ROOM INTERIOR, SHOWING ESCAPE HATCH. Looking north along east wall. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  16. Mutual-information-based image to patient re-registration using intraoperative ultrasound in image-guided neurosurgery

    PubMed Central

    Ji, Songbai; Wu, Ziji; Hartov, Alex; Roberts, David W.; Paulsen, Keith D.

    2008-01-01

    An image-based re-registration scheme has been developed and evaluated that uses fiducial registration as a starting point to maximize the normalized mutual information (nMI) between intraoperative ultrasound (iUS) and preoperative magnetic resonance images (pMR). We show that this scheme significantly (p⪡0.001) reduces tumor boundary misalignment between iUS pre-durotomy and pMR from an average of 2.5 mm to 1.0 mm in six resection surgeries. The corrected tumor alignment before dural opening provides a more accurate reference for assessing subsequent intraoperative tumor displacement, which is important for brain shift compensation as surgery progresses. In addition, we report the translational and rotational capture ranges necessary for successful convergence of the nMI registration technique (5.9 mm and 5.2 deg, respectively). The proposed scheme is automatic, sufficiently robust, and computationally efficient (<2 min), and holds promise for routine clinical use in the operating room during image-guided neurosurgical procedures. PMID:18975707

  17. Effect of tubing length on the dispersion correction of an arterially sampled input function for kinetic modeling in PET.

    PubMed

    O'Doherty, Jim; Chilcott, Anna; Dunn, Joel

    2015-11-01

    Arterial sampling with dispersion correction is routinely performed for kinetic analysis of PET studies. Because of the the advent of PET-MRI systems, non-MR safe instrumentation will be required to be kept outside the scan room, which requires the length of the tubing between the patient and detector to increase, thus worsening the effects of dispersion. We examined the effects of dispersion in idealized radioactive blood studies using various lengths of tubing (1.5, 3, and 4.5 m) and applied a well-known transmission-dispersion model to attempt to correct the resulting traces. A simulation study was also carried out to examine noise characteristics of the model. The model was applied to patient traces using a 1.5 m acquisition tubing and extended to its use at 3 m. Satisfactory dispersion correction of the blood traces was achieved in the 1.5 m line. Predictions on the basis of experimental measurements, numerical simulations and noise analysis of resulting traces show that corrections of blood data can also be achieved using the 3 m tubing. The effects of dispersion could not be corrected for the 4.5 m line by the selected transmission-dispersion model. On the basis of our setup, correction of dispersion in arterial sampling tubing up to 3 m by the transmission-dispersion model can be performed. The model could not dispersion correct data acquired using a 4.5 m arterial tubing.

  18. Newly diagnosed congenital factor VII deficiency and utilization of recombinant activated factor VII (NovoSeven®)

    PubMed Central

    Bartosh, Nicole S; Tomlin, Tara; Cable, Christian; Halka, Kathleen

    2013-01-01

    This case report presents a newly diagnosed congenital factor VII deficiency treated with recombinant activated factor VII (rFVIIa). Congenital factor VII deficiency is a rare autosomal-recessive bleeding disorder that occurs in fewer than 1/500,000 persons. Its presentation can vary from epistaxis to hemarthroses and severe central nervous system bleeding, and correlates poorly with factor VII levels. Our patient had not had a significant hemostatic challenge prior to his presentation and therefore never had any symptomatology suggestive of this disease. He was treated with rFVIIa, and was able to undergo repair of his fractures without bleeding. Case report A 19-year-old African-American male presented to the emergency room after an altercation that resulted in significant trauma. He sustained bilateral mandibular angle fractures and orbital floor fractures, requiring urgent surgical correction. On initial evaluation, he was noted to have a prolonged prothrombin time of 40.1 seconds, with an International Normalized Ratio of 4.0, a normal activated partial thromboplastin time of 29.9 seconds, and a platelet count of 241. After receiving vitamin K and fresh frozen plasma, he was taken to the operating room for a temporary rigid maxillomandibular fixation. A 1:1 mixing study with normal plasma corrected the prothrombin time (decreasing from 40.7 to 14.7 seconds) and a factor VII assay revealed 5% of the normal factor VII level. The patient was diagnosed with congenital factor VII deficiency. Due to his coagulopathy and the extensive surgical correction needed, rFVIIa was administered and surgery was accomplished without hemorrhagic sequelae. Conclusion This case report and review describes a rare congenital disease, the history of rFVIIa use, and its mechanism. rFVIIA use in our patient provided a treatment option that allowed the necessary surgical correction, but further prospective studies on dose optimization would ensure adequate dosing with minimal risk of severe side effects. PMID:23516010

  19. Newly diagnosed congenital factor VII deficiency and utilization of recombinant activated factor VII (NovoSeven(®)).

    PubMed

    Bartosh, Nicole S; Tomlin, Tara; Cable, Christian; Halka, Kathleen

    2013-01-01

    This case report presents a newly diagnosed congenital factor VII deficiency treated with recombinant activated factor VII (rFVIIa). Congenital factor VII deficiency is a rare autosomal-recessive bleeding disorder that occurs in fewer than 1/500,000 persons. Its presentation can vary from epistaxis to hemarthroses and severe central nervous system bleeding, and correlates poorly with factor VII levels. Our patient had not had a significant hemostatic challenge prior to his presentation and therefore never had any symptomatology suggestive of this disease. He was treated with rFVIIa, and was able to undergo repair of his fractures without bleeding. A 19-year-old African-American male presented to the emergency room after an altercation that resulted in significant trauma. He sustained bilateral mandibular angle fractures and orbital floor fractures, requiring urgent surgical correction. On initial evaluation, he was noted to have a prolonged prothrombin time of 40.1 seconds, with an International Normalized Ratio of 4.0, a normal activated partial thromboplastin time of 29.9 seconds, and a platelet count of 241. After receiving vitamin K and fresh frozen plasma, he was taken to the operating room for a temporary rigid maxillomandibular fixation. A 1:1 mixing study with normal plasma corrected the prothrombin time (decreasing from 40.7 to 14.7 seconds) and a factor VII assay revealed 5% of the normal factor VII level. The patient was diagnosed with congenital factor VII deficiency. Due to his coagulopathy and the extensive surgical correction needed, rFVIIa was administered and surgery was accomplished without hemorrhagic sequelae. This case report and review describes a rare congenital disease, the history of rFVIIa use, and its mechanism. rFVIIA use in our patient provided a treatment option that allowed the necessary surgical correction, but further prospective studies on dose optimization would ensure adequate dosing with minimal risk of severe side effects.

  20. [Focus on the role of ventilation and ultraviolet rays in preventing nosocomial transmission of tuberculosis in health care facilities. Groupe de travail sur la prévention de la transmission nosocomiale de la tuberculose (Direction Générale de la Santé)].

    PubMed

    Desenclos, J C; Abiteboul, D; Bouvet, E; Brucker, G; Demeulemester, R; Haury, B; Huré, P; Leprince, A; Macrez, A; Mayaud, C

    1995-01-01

    Recent episodes of nosocomial tuberculosis, sometimes due to multiresistant strains, in HIV infected patients in the USA has led to the need for new prevention measures against the transmission of Mycobacterium tuberculosis in health care facilities. Tuberculosis is transmitted in Pflügge droplets generated when contagious persons cough. After drying, the droplets become aerosolized solid particles which are rapidly dispersed by air flow within the patient's room. People exposed to the same air are thus at high risk of being contaminated. If the air pressure in the patient's room is higher than the rest of the facility, the air coming form the room may contaminate personnel and other patients elsewhere in the facility. Infecting particles can be eliminated rapidly if the room air is ventilated outdoors. If the ventilation is strong enough so that air constantly circulates from the corridor into the room, infecting particles can no longer diffuse to the rest of the ward. It is also possible to use ultraviolet C light to disinfect the air, either within the room or within the ventilation system. These two basically simple systems are the fundamental environmental and prevention measures needed to limit tuberculosis spread in health care facilities. These methods are however technically complex, costly and require constant evaluation and maintenance by specialized personnel. In addition the potential side effects of ultraviolet waves could considerably reduce their application. These environmental methods, which are complementary methods, only have a meaning if the elementary measures for preventing the transmission of tuberculosis are correctly applied.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Advanced Infrared Photodetectors (Materials Review)

    DTIC Science & Technology

    1993-12-01

    Telluride DMS Dilute Magnetic Semiconductor R)V Field of View FPP Focal Plane Processing IR Infrared LPE Liquid Phase Epitaxy LWIR Long Wave Infrared...operation is normal. Photoconductive (PC) cadmium mercury telluride (CdxHgl-xTe. x - 0.167) has a LWIR cutoff at room temperature; however, operation is...reliability, lightweight On-chip clocks and bias circuits An initial use of FPP is nonuniformity correction (NUC) since spatial response nonuniformity is

  2. Optimal Sensor Scheduling for Multiple Hypothesis Testing

    DTIC Science & Technology

    1981-09-01

    Naval Research, under contract N00014-77-0532 is gratpfully acknowledged. 2 Laboratory for Information and Decision Systems , MIT Room 35-213, Cambridge...treat the more general problem [9,10]. However, two common threads connect these approaches: they obtain feedback laws mapping posterior destributions ...objective of a detection or identification algorithm is to produce correct estimates of the true state of a system . It is also bene- ficial if these

  3. Issues and Strategies for Improving Constructibility.

    DTIC Science & Technology

    1988-09-01

    materials. First, the roof design called for the use of an asphalt coated roof felt layer below an EPDM membrane. The asphalt coated felt is not needed when a...being prepared by people trained in subjects foreign to construction. As designers, we were in fact contractually and professionally isolated from...specially constructed for sound isolation . The architect* correctly specified special sound seals around the doors between the rooms in this area, but

  4. Linear Collider Test Facility: Twiss Parameter Analysis at the IP/Post-IP Location of the ATF2 Beam Line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolzon, Benoit; /Annecy, LAPP; Jeremie, Andrea

    2012-07-02

    At the first stage of the ATF2 beam tuning, vertical beam size is usually bigger than 3 {micro}m at the IP. Beam waist measurements using wire scanners and a laser wire are usually performed to check the initial matching of the beam through to the IP. These measurements are described in this paper for the optics currently used ({beta}{sub x} = 4cm and {beta}{sub y} = 1mm). Software implemented in the control room to automate these measurements with integrated analysis is also described. Measurements showed that {beta} functions and emittances were within errors of measurements when no rematching and couplingmore » corrections were done. However, it was observed that the waist in the horizontal (X) and vertical (Y) plane was abnormally shifted and simulations were performed to try to understand these shifts. They also showed that multiknobs are needed in the current optics to correct simultaneously {alpha}{sub x}, {alpha}{sub y} and the horizontal dispersion (D{sub x}). Such multiknobs were found and their linearity and orthogonality were successfully checked using MAD optics code. The software for these multiknobs was implemented in the control room and waist scan measurements using the {alpha}{sub y} knob were successfully performed.« less

  5. Dental occlusion ties: A rapid, safe, and non‐invasive maxillo‐mandibular fixation technology

    PubMed Central

    2017-01-01

    Objectives For decades, Erich arch bars have been a standard in establishing maxillo‐mandibular fixation (MMF). While reliable, the approach risks sharps injury, consumes operating room time, and inflicts gingival trauma. Newer technologies including screw‐based techniques and “hybrid” techniques have improved MMF by reducing sharps injuries and operating room time, but risk injury to tooth roots, nerves, and gingiva. This study aims to establish the application, strengths, and limitations of dental occlusion ties as a novel alternative in maxillo‐mandibular fixation. Study Design Prospective, non‐blinded, human feasibility clinical trial. Materials and Methods An iterative prototyping process was used to invent dental occlusion ties (brand name: Minne Ties). Development included 3D printing, cadaver prototype testing, human apical embrasure measurement, and ultimately non‐significant risk human clinical trial testing. In the IRB‐approved feasibility clinical trial, the devices were applied to mandible and maxilla fracture candidates with fractures amenable to intra‐operative MMF with open reduction with internal fixation. The ties were removed prior to extubation. Pre‐teens, comminuted fracture patients, and patients requiring post‐operative MMF were excluded. Results Manufactured, sterile prototypes secured MMF successfully in management of unilateral and bilateral mandible and maxilla fractures. All patients reported correction of pre‐operative malocclusion. Application times were typically 12–15 minutes for a single surgeon to achieve MMF. Patients incurred negligible gingival trauma from the technology as the ties require no tissue penetration for application. Conclusions Dental occlusion ties offer a non‐invasive solution featuring operating room efficiency, minimized sharps risk, and less bony and soft tissue trauma than current commercialized solutions. Level of Evidence Therapeutic, IV PMID:28894837

  6. Perinatal nursing education for single-room maternity care: an evaluation of a competency-based model.

    PubMed

    Janssen, Patricia A; Keen, Lois; Soolsma, Jetty; Seymour, Laurie C; Harris, Susan J; Klein, Michael C; Reime, Birgit

    2005-01-01

    To evaluate the success of a competency-based nursing orientation programme for a single-room maternity care unit by measuring improvement in self-reported competency after six months. Single-room maternity care has challenged obstetrical nurses to provide comprehensive nursing care during all phases of the in-hospital birth experience. In this model, nurses provide intrapartum, postpartum and newborn care in one room. To date, an evaluation of nursing education for single-room maternity care has not been published. A prospective cohort design comparing self-reported competencies prior to starting work in the single-room maternity care and six months after. Nurses completed a competency-based education programme in which they could select from a menu of learning methods and content areas according to their individual needs. Learning methods included classroom lectures, self-paced learning packages, and preceptorships in the clinical area. Competencies were measured by a standardized perinatal self-efficacy tool and a tool developed by the authors for this study, the Single-Room Maternity Care Competency Tool. A paired analysis was undertaken to take into account the paired (before and after) nature of the design. Scores on the perinatal self-efficacy scale and the single-room maternity care competency tool were improved. These differences were statistically significant. Improvements in perinatal and single-room maternity care-specific competencies suggest that our education programme was successful in preparing nurses for their new role in the single-room maternity care setting. This conclusion is supported by reported increases in nursing and patient satisfaction in the single-room maternity care compared with the traditional labour/delivery and postpartum settings. An education programme tailored to the learning needs of experienced clinical nurses contributes to improvements in nursing competencies and patient care.

  7. Indoor radon regulation using tabulated values of temporal radon variation.

    PubMed

    Tsapalov, Andrey; Kovler, Konstantin

    2018-03-01

    Mass measurements of indoor radon concentrations have been conducted for about 30 years. In most of the countries, a national reference/action/limit level is adopted, limiting the annual average indoor radon (AAIR) concentration. However, until now, there is no single and generally accepted international protocol for determining the AAIR with a known confidence interval, based on measurements of different durations. Obviously, as the duration of measurements increases, the uncertainty of the AAIR estimation decreases. The lack of the information about the confidence interval of the determined AAIR level does not allow correct comparison with the radon reference level. This greatly complicates development of an effective indoor radon measurement protocol and strategy. The paper proposes a general principle of indoor radon regulation, based on the simple criteria widely used in metrology, and introduces a new parameter - coefficient of temporal radon variation K V (t) that depends on the measurement duration and determines the uncertainty of the AAIR. An algorithm for determining K V (t) based on the results of annual continuous radon monitoring in experimental rooms is proposed. Included are indoor radon activity concentrations and equilibrium equivalent concentration (EEC) of radon progeny. The monitoring was conducted in 10 selected experimental rooms located in 7 buildings, mainly in the Moscow region (Russia), from 2006 to 2013. The experimental and tabulated values of K V (t) and also the values of the coefficient of temporal EEC variation depending on the mode and duration of the measurements were obtained. The recommendations to improve the efficiency and reliability of indoor radon regulation are given. The importance of taking into account the geological factors is discussed. The representativity of the results of the study is estimated and the approach for their verification is proposed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Airborne sound insulation evaluation and flanking path prediction of coupled room

    NASA Astrophysics Data System (ADS)

    Tassia, R. D.; Asmoro, W. A.; Arifianto, D.

    2016-11-01

    One of the parameters to review the acoustic comfort is based on the value of the insulation partition in the classroom. The insulation value can be expressed by the sound transmission loss which converted into a single value as weighted sound reduction index (Rw, DnTw) and also have an additional sound correction factor in low frequency (C, Ctr) .In this study, the measurements were performed in two positions at each point using BSWA microphone and dodecahedron speaker as the sound source. The results of field measurements indicate the acoustic insulation values (DnT w + C) is 19.6 dB. It is noted that the partition wall not according to the standard which the DnTw + C> 51 dB. Hence the partition wall need to be redesign to improve acoustic insulation in the classroom. The design used gypsum board, plasterboard, cement board, and PVC as the replacement material. Based on the results, all the material is simulated in accordance with established standards. Best insulation is cement board with the insulation value is 69dB, the thickness of 12.5 mm on each side and the absorber material is 50 mm. Many factors lead to increase the value of acoustic insulation, such as the thickness of the panel, the addition of absorber material, density, and Poisson's ratio of a material. The prediction of flanking path can be estimated from noise reduction values at each measurement point in the class room. Based on data obtained, there is no significant change in noise reduction from each point so that the pathway of flanking is not affect the sound transmission in the classroom.

  9. Implementation and evaluation of an interprofessional simulation-based education program for undergraduate nursing students in operating room nursing education: a randomized controlled trial.

    PubMed

    Wang, Rongmei; Shi, Nianke; Bai, Jinbing; Zheng, Yaguang; Zhao, Yue

    2015-07-09

    The present study was designed to implement an interprofessional simulation-based education program for nursing students and evaluate the influence of this program on nursing students' attitudes toward interprofessional education and knowledge about operating room nursing. Nursing students were randomly assigned to either the interprofessional simulation-based education or traditional course group. A before-and-after study of nursing students' attitudes toward the program was conducted using the Readiness for Interprofessional Learning Scale. Responses to an open-ended question were categorized using thematic content analysis. Nursing students' knowledge about operating room nursing was measured. Nursing students from the interprofessional simulation-based education group showed statistically different responses to four of the nineteen questions in the Readiness for Interprofessional Learning Scale, reflecting a more positive attitude toward interprofessional learning. This was also supported by thematic content analysis of the open-ended responses. Furthermore, nursing students in the simulation-based education group had a significant improvement in knowledge about operating room nursing. The integrated course with interprofessional education and simulation provided a positive impact on undergraduate nursing students' perceptions toward interprofessional learning and knowledge about operating room nursing. Our study demonstrated that this course may be a valuable elective option for undergraduate nursing students in operating room nursing education.

  10. Operating room management and operating room productivity: the case of Germany.

    PubMed

    Berry, Maresi; Berry-Stölzle, Thomas; Schleppers, Alexander

    2008-09-01

    We examine operating room productivity on the example of hospitals in Germany with independent anesthesiology departments. Linked to anesthesiology group literature, we use the ln(Total Surgical Time/Total Anesthesiologists Salary) as a proxy for operating room productivity. We test the association between operating room productivity and different structural, organizational and management characteristics based on survey data from 87 hospitals. Our empirical analysis links improved operating room productivity to greater operating room capacity, appropriate scheduling behavior and management methods to realign interests. From this analysis, the enforcing jurisdiction and avoiding advance over-scheduling appear to be the implementable tools for improving operating room productivity.

  11. JPSS-1 VIIRS Version 2 At-Launch Relative Spectral Response Characterization and Performance

    NASA Technical Reports Server (NTRS)

    Moeller, Chris; Schwarting, Thomas; McIntire, Jeff; Moyer, Dave; Zeng, Jinan

    2017-01-01

    The relative spectral response (RSR) characterization of the JPSS-1 VIIRS spectral bands has achieved at launch status in the VIIRS Data Analysis Working Group February 2016 Version 2 RSR release. The Version 2 release improves upon the June 2015 Version 1 release by including December 2014 NIST TSIRCUS spectral measurements of VIIRS VisNIR bands in the analysis plus correcting CO2 influence on the band M13 RSR. The T-SIRCUS based characterization is merged with the summer 2014 SpMA based characterization of VisNIR bands (Version 1 release) to yield a fused RSR for these bands, combining the strengths of the T-SIRCUS and the SpMA measurement systems. The M13 RSR is updated by applying a model-based correction to mitigate CO2 attenuation of the SpMA source signal that occurred during M13 spectral measurements. The Version 2 release carries forward the Version 1 RSR for those bands that were not updated (M8-M12, M14-M16AB, I3-I5, DNBMGS). The Version 2 release includes band average (overall detectors and subsamples) RSR plus supporting RSR for each detector and subsample. The at-launch band average RSR have been used to populate Look-Up Tables supporting the sensor data record and environmental data record at-launch science products. Spectral performance metrics show that JPSS-1VIIRS RSR are compliant on specifications with a few minor exceptions. The Version 2 release, which replaces the Version 1 release, is currently available on the password-protected NASA JPSS-1 eRooms under EAR99 control.

  12. 1. TERMINAL ROOM, INTERIOR, SHOP LEVEL, SHOWING FIRE EXTINGUISHING SYSTEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. TERMINAL ROOM, INTERIOR, SHOP LEVEL, SHOWING FIRE EXTINGUISHING SYSTEM PIPES AND VALVES AT LEFT. Looking southeast from entrance to terminal room. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  13. An exploration of the basis for patient complaints about the oldness of magazines in practice waiting rooms: cohort study.

    PubMed

    Arroll, Bruce; Alrutz, Stowe; Moyes, Simon

    2014-12-11

    To explore the basis for patient complaints about the oldness of most magazines in practice waiting rooms. Cohort study. Waiting room of a general practice in Auckland, New Zealand. 87 magazines stacked into three mixed piles and placed in the waiting room: this included non-gossipy magazines (Time magazine, the Economist, Australian Women's Weekly, National Geographic, BBC History) and gossipy ones (not identified for fear of litigation). Gossipy was defined as having five or more photographs of celebrities on the front cover and most gossipy as having up to 10 such images. The magazines were marked with a unique number on the back cover, placed in three piles in the waiting room, and monitored twice weekly. Disappearance of magazines less than 2 months old versus magazines 3-12 months old, the overall rate of loss of magazines, and the rate of loss of gossipy versus non-gossipy magazines. 47 of the 82 magazines with a visible date on the front cover were aged less than 2 months. 28 of these 47 (60%) magazines and 10 of the 35 (29%) older magazines disappeared (P=0.002). After 31 days, 41 of the 87 (47%, 95% confidence interval 37% to 58%) magazines had disappeared. None of the 19 non-gossipy magazines (the Economist and Time magazine) had disappeared compared with 26 of the 27 (96%) gossipy magazines (P<0.001). All 15 of the most gossipy magazines and none of the non-gossipy magazines [corrected] had disappeared by 31 days. The study was terminated at this point. General practice waiting rooms contain mainly old magazines. This phenomenon relates to the disappearance of the magazines rather than to the supply of old ones. Gossipy magazines were more likely to disappear than non-gossipy ones. On the grounds of cost we advise practices to supply old copies of non-gossipy magazines. A waiting room science curriculum is urgently needed. © Arroll et al 2014.

  14. Image guidance during head-and-neck cancer radiation therapy: analysis of alignment trends with in-room cone-beam computed tomography scans.

    PubMed

    Zumsteg, Zachary; DeMarco, John; Lee, Steve P; Steinberg, Michael L; Lin, Chun Shu; McBride, William; Lin, Kevin; Wang, Pin-Chieh; Kupelian, Patrick; Lee, Percy

    2012-06-01

    On-board cone-beam computed tomography (CBCT) is currently available for alignment of patients with head-and-neck cancer before radiotherapy. However, daily CBCT is time intensive and increases the overall radiation dose. We assessed the feasibility of using the average couch shifts from the first several CBCTs to estimate and correct for the presumed systematic setup error. 56 patients with head-and-neck cancer who received daily CBCT before intensity-modulated radiation therapy had recorded shift values in the medial-lateral, superior-inferior, and anterior-posterior dimensions. The average displacements in each direction were calculated for each patient based on the first five or 10 CBCT shifts and were presumed to represent the systematic setup error. The residual error after this correction was determined by subtracting the calculated shifts from the shifts obtained using daily CBCT. The magnitude of the average daily residual three-dimensional (3D) error was 4.8 ± 1.4 mm, 3.9 ± 1.3 mm, and 3.7 ± 1.1 mm for uncorrected, five CBCT corrected, and 10 CBCT corrected protocols, respectively. With no image guidance, 40.8% of fractions would have been >5 mm off target. Using the first five CBCT shifts to correct subsequent fractions, this percentage decreased to 19.0% of all fractions delivered and decreased the percentage of patients with average daily 3D errors >5 mm from 35.7% to 14.3% vs. no image guidance. Using an average of the first 10 CBCT shifts did not significantly improve this outcome. Using the first five CBCT shift measurements as an estimation of the systematic setup error improves daily setup accuracy for a subset of patients with head-and-neck cancer receiving intensity-modulated radiation therapy and primarily benefited those with large 3D correction vectors (>5 mm). Daily CBCT is still necessary until methods are developed that more accurately determine which patients may benefit from alternative imaging strategies. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Apnea in Children Hospitalized With Bronchiolitis

    PubMed Central

    Mansbach, Jonathan M.; Stevenson, Michelle; Macias, Charles G.; Fisher, Erin Stucky; Barcega, Besh; Sullivan, Ashley F.; Espinola, Janice A.; Piedra, Pedro A.; Camargo, Carlos A.

    2013-01-01

    OBJECTIVE: To identify risk factors for inpatient apnea among children hospitalized with bronchiolitis. METHODS: We enrolled 2207 children, aged <2 years, hospitalized with bronchiolitis at 16 sites during the winters of 2007 to 2010. Nasopharyngeal aspirates (NPAs) were obtained on all subjects, and real-time polymerase chain reaction was used to test NPA samples for 16 viruses. Inpatient apnea was ascertained by daily chart review, with outcome data in 2156 children (98%). Age was corrected for birth <37 weeks. Multivariable logistic regression was performed to identify independent risk factors for inpatient apnea. RESULTS: Inpatient apnea was identified in 108 children (5%, 95% confidence interval [CI] 4%–6%). Statistically significant, independent predictors of inpatient apnea included: corrected ages of <2 weeks (odds ratio [OR] 9.67) and 2 to 8 weeks (OR 4.72), compared with age ≥6 months; birth weight <2.3 kg (5 pounds; OR 2.15), compared with ≥3.2 kg (7 pounds); caretaker report of previous apnea during this bronchiolitis episode (OR 3.63); preadmission respiratory rates of <30 (OR 4.05), 30 to 39 (OR 2.35) and >70 (OR 2.26), compared with 40 to 49; and having a preadmission room air oxygen saturation <90% (OR 1.60). Apnea risk was similar across the major viral pathogens. CONCLUSIONS: In this prospective, multicenter study of children hospitalized with bronchiolitis, inpatient apnea was associated with younger corrected age, lower birth weight, history of apnea, and preadmission clinical factors including low or high respiratory rates and low room air oxygen saturation. Several bronchiolitis pathogens were associated with apnea, with similar apnea risk across the major viral pathogens. PMID:24101759

  16. Real-time monitoring for detection of retained surgical sponges and team motion in the surgical operation room using radio-frequency-identification (RFID) technology: a preclinical evaluation.

    PubMed

    Kranzfelder, Michael; Zywitza, Dorit; Jell, Thomas; Schneider, Armin; Gillen, Sonja; Friess, Helmut; Feussner, Hubertus

    2012-06-15

    Technical progress in the surgical operating room (OR) increases constantly, facilitating the development of intelligent OR systems functioning as "safety backup" in the background of surgery. Precondition is comprehensive data retrieval to identify imminent risky situations and inaugurate adequate security mechanisms. Radio-frequency-identification (RFID) technology may have the potential to meet these demands. We set up a pilot study investigating feasibility and appliance reliability of a stationary RFID system for real-time surgical sponge monitoring (passive tagged sponges, position monitoring: mayo-stand/abdominal situs/waste bucket) and OR team tracking (active transponders, position monitoring: right/left side of OR table). In vitro: 20/20 sponges (100%) were detected on the mayo-stand and within the OR-phantom, however, real-time detection accuracy declined to 7/20 (33%) when the tags were moved simultaneously. All retained sponges were detected correctly. In vivo (animal): 7-10/10 sterilized sponges (70%-100%) were detected correctly within the abdominal cavity. OR-team: detection accuracy within the OR (surveillance antenna) and on both sides of the OR table (sector antenna) was 100%. Mean detection time for position change (left to right side and contrariwise) was 30-60 s. No transponder failure was noted. This is the first combined RFID system that has been developed for stationary use in the surgical OR. Preclinical evaluation revealed a reliable sponge tracking and correct detection of retained textiles (passive RFID) but also demonstrated feasibility of comprehensive data acquisition of team motion (active RFID). However, detection accuracy needs to be further improved before implementation into the surgical OR. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. 133. SOUTH SIDE OF TRANSFORMER ROOM (212), LSB (BLDG. 751), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    133. SOUTH SIDE OF TRANSFORMER ROOM (212), LSB (BLDG. 751), WITH MECHANICAL AND ELECTRICAL ROOM (210) AND LANDLINE INSTRUMENTATION ROOM (206) VISIBLE THROUGH OPEN DOORS. POWER PANEL A, FACING WEST, AT LEFT EDGE OF PHOTOGRAPH. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. High-Tech Terror: Al-Qaeda’s Use of New Technology

    DTIC Science & Technology

    2006-01-01

    jihadi movement’s use of email, chat rooms, online magazines, cell phone videos, CD-ROMs, and even video games look for immediate intelligence... VIDEO GAMES AND JIHAD Although counterterrorism analysts correctly focus on the ways in which jihadis employ new technologies to advance their...important to note that many video games available to youth in the West are equally or even more violent than the jihadi versions. Additionally, there is no

  19. Medical Services Career Ladder (AFSC 902XO/A/B)

    DTIC Science & Technology

    1992-02-01

    the manner specified by the AFR 39-1 Specialty Description and may serve as a basis for considering changes to current utilization policies and...medical facility policies 59 F285 Apply tape or nonelastic bandages 59 E147 Answer patient telephone inquiries 58 H441 Maintain treatment room supplies 57...medical facility policies 55 A14 Establish performance standards for subordinates 55 B58 Initiate actions to correct substandard performance of

  20. Gigabit free-space multi-level signal transmission with a mid-infrared quantum cascade laser operating at room temperature.

    PubMed

    Pang, Xiaodan; Ozolins, Oskars; Schatz, Richard; Storck, Joakim; Udalcovs, Aleksejs; Navarro, Jaime Rodrigo; Kakkar, Aditya; Maisons, Gregory; Carras, Mathieu; Jacobsen, Gunnar; Popov, Sergei; Lourdudoss, Sebastian

    2017-09-15

    Gigabit free-space transmissions are experimentally demonstrated with a quantum cascaded laser (QCL) emitting at mid-wavelength infrared of 4.65 μm, and a commercial infrared photovoltaic detector. The QCL operating at room temperature is directly modulated using on-off keying and, for the first time, to the best of our knowledge, four- and eight-level pulse amplitude modulations (PAM-4, PAM-8). By applying pre- and post-digital equalizations, we achieve up to 3  Gbit/s line data rate in all three modulation configurations with a bit error rate performance of below the 7% overhead hard decision forward error correction limit of 3.8×10 -3 . The proposed transmission link also shows a stable operational performance in the lab environment.

  1. Conceptual design of BNCT facility based on the TRR medical room

    NASA Astrophysics Data System (ADS)

    Golshanian, M.; Rajabi, A. A.; Kasesaz, Y.

    2017-10-01

    This paper presents a conceptual design of the Boron Neutron Capture Therapy (BNCT) facility based on the medical room of Tehran Research Reactor (TRR). The medical room is located behind the east wall of the reactor pool. The designed beam line is an in-pool Beam Shaping Assembly (BSA) which is considered between the reactor core and the medical room wall. The final designed BSA can provide 2.96× 109 n/cm2ṡs epithermal neutron flux at the irradiation position with acceptable beam contamination to use as a clinical BNCT.

  2. Action research to improve methods of delivery and feedback in an Access Grid Room environment

    NASA Astrophysics Data System (ADS)

    McArthur, Lynne C.; Klass, Lara; Eberhard, Andrew; Stacey, Andrew

    2011-12-01

    This article describes a qualitative study which was undertaken to improve the delivery methods and feedback opportunity in honours mathematics lectures which are delivered through Access Grid Rooms. Access Grid Rooms are facilities that provide two-way video and audio interactivity across multiple sites, with the inclusion of smart boards. The principal aim was to improve the student learning experience, given the new environment. The specific aspects of the course delivery that the study focused on included presentation of materials and provision of opportunities for interaction between the students and between students and lecturers. The practical considerations in the delivery of distance learning are well documented in the literature, and similar problems arise in the Access Grid Room environment; in particular, those of limited access to face-to-face interaction and the reduction in peer support. The nature of the Access Grid Room classes implies that students studying the same course can be physically situated in different cities, and possibly in different countries. When studying, it is important that students have opportunity to discuss new concepts with others; particularly their peers and their lecturer. The Access Grid Room environment also presents new challenges for the lecturer, who must learn new skills in the delivery of materials. The unique nature of Access Grid Room technology offers unprecedented opportunity for effective course delivery and positive outcomes for students, and was developed in response to a need to be able to interact with complex data, other students and the instructor, in real-time, at a distance and from multiple sites. This is a relatively new technology and as yet there has been little or no studies specifically addressing the use and misuse of the technology. The study found that the correct placement of cameras and the use of printed material and smart boards were all crucial to the student experience. In addition, the inclusion of special tutorial type sessions were necessary to provide opportunities to students for one-on-one discussion with both lecturer and other students. This study contributes to the broader understanding of distance education in general and future Access Grid Room course delivery in particular.

  3. 24. INTERIOR OF CENTRAL ROOM. BASE POWER PANEL VISIBLE ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. INTERIOR OF CENTRAL ROOM. BASE POWER PANEL VISIBLE ON RIGHT WALL OF HALLWAY. - Chollas Heights Naval Radio Transmitting Facility, Transmitter Building, 6410 Zero Road, San Diego, San Diego County, CA

  4. Integrating Retraction Modeling Into an Atlas-Based Framework for Brain Shift Prediction

    PubMed Central

    Chen, Ishita; Ong, Rowena E.; Simpson, Amber L.; Sun, Kay; Thompson, Reid C.

    2015-01-01

    In recent work, an atlas-based statistical model for brain shift prediction, which accounts for uncertainty in the intraoperative environment, has been proposed. Previous work reported in the literature using this technique did not account for local deformation caused by surgical retraction. It is challenging to precisely localize the retractor location prior to surgery and the retractor is often moved in the course of the procedure. This paper proposes a technique that involves computing the retractor-induced brain deformation in the operating room through an active model solve and linearly superposing the solution with the precomputed deformation atlas. As a result, the new method takes advantage of the atlas-based framework’s accounting for uncertainties while also incorporating the effects of retraction with minimal intraoperative computing. This new approach was tested using simulation and phantom experiments. The results showed an improvement in average shift correction from 50% (ranging from 14 to 81%) for gravity atlas alone to 80% using the active solve retraction component (ranging from 73 to 85%). This paper presents a novel yet simple way to integrate retraction into the atlas-based brain shift computation framework. PMID:23864146

  5. Parameter Estimation and Model Selection for Indoor Environments Based on Sparse Observations

    NASA Astrophysics Data System (ADS)

    Dehbi, Y.; Loch-Dehbi, S.; Plümer, L.

    2017-09-01

    This paper presents a novel method for the parameter estimation and model selection for the reconstruction of indoor environments based on sparse observations. While most approaches for the reconstruction of indoor models rely on dense observations, we predict scenes of the interior with high accuracy in the absence of indoor measurements. We use a model-based top-down approach and incorporate strong but profound prior knowledge. The latter includes probability density functions for model parameters and sparse observations such as room areas and the building footprint. The floorplan model is characterized by linear and bi-linear relations with discrete and continuous parameters. We focus on the stochastic estimation of model parameters based on a topological model derived by combinatorial reasoning in a first step. A Gauss-Markov model is applied for estimation and simulation of the model parameters. Symmetries are represented and exploited during the estimation process. Background knowledge as well as observations are incorporated in a maximum likelihood estimation and model selection is performed with AIC/BIC. The likelihood is also used for the detection and correction of potential errors in the topological model. Estimation results are presented and discussed.

  6. QIN DAWG Validation of Gradient Nonlinearity Bias Correction Workflow for Quantitative Diffusion-Weighted Imaging in Multicenter Trials.

    PubMed

    Malyarenko, Dariya I; Wilmes, Lisa J; Arlinghaus, Lori R; Jacobs, Michael A; Huang, Wei; Helmer, Karl G; Taouli, Bachir; Yankeelov, Thomas E; Newitt, David; Chenevert, Thomas L

    2016-12-01

    Previous research has shown that system-dependent gradient nonlinearity (GNL) introduces a significant spatial bias (nonuniformity) in apparent diffusion coefficient (ADC) maps. Here, the feasibility of centralized retrospective system-specific correction of GNL bias for quantitative diffusion-weighted imaging (DWI) in multisite clinical trials is demonstrated across diverse scanners independent of the scanned object. Using corrector maps generated from system characterization by ice-water phantom measurement completed in the previous project phase, GNL bias correction was performed for test ADC measurements from an independent DWI phantom (room temperature agar) at two offset locations in the bore. The precomputed three-dimensional GNL correctors were retrospectively applied to test DWI scans by the central analysis site. The correction was blinded to reference DWI of the agar phantom at magnet isocenter where the GNL bias is negligible. The performance was evaluated from changes in ADC region of interest histogram statistics before and after correction with respect to the unbiased reference ADC values provided by sites. Both absolute error and nonuniformity of the ADC map induced by GNL (median, 12%; range, -35% to +10%) were substantially reduced by correction (7-fold in median and 3-fold in range). The residual ADC nonuniformity errors were attributed to measurement noise and other non-GNL sources. Correction of systematic GNL bias resulted in a 2-fold decrease in technical variability across scanners (down to site temperature range). The described validation of GNL bias correction marks progress toward implementation of this technology in multicenter trials that utilize quantitative DWI.

  7. QIN DAWG Validation of Gradient Nonlinearity Bias Correction Workflow for Quantitative Diffusion-Weighted Imaging in Multicenter Trials

    PubMed Central

    Malyarenko, Dariya I.; Wilmes, Lisa J.; Arlinghaus, Lori R.; Jacobs, Michael A.; Huang, Wei; Helmer, Karl G.; Taouli, Bachir; Yankeelov, Thomas E.; Newitt, David; Chenevert, Thomas L.

    2017-01-01

    Previous research has shown that system-dependent gradient nonlinearity (GNL) introduces a significant spatial bias (nonuniformity) in apparent diffusion coefficient (ADC) maps. Here, the feasibility of centralized retrospective system-specific correction of GNL bias for quantitative diffusion-weighted imaging (DWI) in multisite clinical trials is demonstrated across diverse scanners independent of the scanned object. Using corrector maps generated from system characterization by ice-water phantom measurement completed in the previous project phase, GNL bias correction was performed for test ADC measurements from an independent DWI phantom (room temperature agar) at two offset locations in the bore. The precomputed three-dimensional GNL correctors were retrospectively applied to test DWI scans by the central analysis site. The correction was blinded to reference DWI of the agar phantom at magnet isocenter where the GNL bias is negligible. The performance was evaluated from changes in ADC region of interest histogram statistics before and after correction with respect to the unbiased reference ADC values provided by sites. Both absolute error and nonuniformity of the ADC map induced by GNL (median, 12%; range, −35% to +10%) were substantially reduced by correction (7-fold in median and 3-fold in range). The residual ADC nonuniformity errors were attributed to measurement noise and other non-GNL sources. Correction of systematic GNL bias resulted in a 2-fold decrease in technical variability across scanners (down to site temperature range). The described validation of GNL bias correction marks progress toward implementation of this technology in multicenter trials that utilize quantitative DWI. PMID:28105469

  8. Prepare to protect: Operating and maintaining a tornado safe room.

    PubMed

    Herseth, Andrew; Goldsmith-Grinspoon, Jennifer; Scott, Pataya

    2017-06-01

    Operating and maintaining a tornado safe room can be critical to the effective continuity of business operations because a firm's most valuable asset is its people. This paper describes aspects of operations and maintenance (O&M) for existing tornado safe rooms as well as a few planning and design aspects that affect the ultimate operation of a safe room for situations where a safe room is planned, but not yet constructed. The information is based on several Federal Emergency Management Agency safe room publications that provide guidance on emergency management and operations, as well as the design and construction of tornado safe rooms.

  9. Improving operating room safety

    PubMed Central

    2009-01-01

    Despite the introduction of the Universal Protocol, patient safety in surgery remains a daily challenge in the operating room. This present study describes one community health system's efforts to improve operating room safety through human factors training and ultimately the development of a surgical checklist. Using a combination of formal training, local studies documenting operating room safety issues and peer to peer mentoring we were able to substantially change the culture of our operating room. Our efforts have prepared us for successfully implementing a standardized checklist to improve operating room safety throughout our entire system. Based on these findings we recommend a multimodal approach to improving operating room safety. PMID:19930577

  10. Floor Covering and Surface Identification for Assistive Mobile Robotic Real-Time Room Localization Application

    PubMed Central

    Gillham, Michael; Howells, Gareth; Spurgeon, Sarah; McElroy, Ben

    2013-01-01

    Assistive robotic applications require systems capable of interaction in the human world, a workspace which is highly dynamic and not always predictable. Mobile assistive devices face the additional and complex problem of when and if intervention should occur; therefore before any trajectory assistance is given, the robotic device must know where it is in real-time, without unnecessary disruption or delay to the user requirements. In this paper, we demonstrate a novel robust method for determining room identification from floor features in a real-time computational frame for autonomous and assistive robotics in the human environment. We utilize two inexpensive sensors: an optical mouse sensor for straightforward and rapid, texture or pattern sampling, and a four color photodiode light sensor for fast color determination. We show how data relating floor texture and color obtained from typical dynamic human environments, using these two sensors, compares favorably with data obtained from a standard webcam. We show that suitable data can be extracted from these two sensors at a rate 16 times faster than a standard webcam, and that these data are in a form which can be rapidly processed using readily available classification techniques, suitable for real-time system application. We achieved a 95% correct classification accuracy identifying 133 rooms' flooring from 35 classes, suitable for fast coarse global room localization application, boundary crossing detection, and additionally some degree of surface type identification. PMID:24351647

  11. Floor covering and surface identification for assistive mobile robotic real-time room localization application.

    PubMed

    Gillham, Michael; Howells, Gareth; Spurgeon, Sarah; McElroy, Ben

    2013-12-17

    Assistive robotic applications require systems capable of interaction in the human world, a workspace which is highly dynamic and not always predictable. Mobile assistive devices face the additional and complex problem of when and if intervention should occur; therefore before any trajectory assistance is given, the robotic device must know where it is in real-time, without unnecessary disruption or delay to the user requirements. In this paper, we demonstrate a novel robust method for determining room identification from floor features in a real-time computational frame for autonomous and assistive robotics in the human environment. We utilize two inexpensive sensors: an optical mouse sensor for straightforward and rapid, texture or pattern sampling, and a four color photodiode light sensor for fast color determination. We show how data relating floor texture and color obtained from typical dynamic human environments, using these two sensors, compares favorably with data obtained from a standard webcam. We show that suitable data can be extracted from these two sensors at a rate 16 times faster than a standard webcam, and that these data are in a form which can be rapidly processed using readily available classification techniques, suitable for real-time system application. We achieved a 95% correct classification accuracy identifying 133 rooms' flooring from 35 classes, suitable for fast coarse global room localization application, boundary crossing detection, and additionally some degree of surface type identification.

  12. Neutron absorbing room temperature vulcanizable silicone rubber compositions

    DOEpatents

    Zoch, Harold L.

    1979-11-27

    A neutron absorbing composition comprising a one-component room temperature vulcanizable silicone rubber composition or a two-component room temperature vulcanizable silicone rubber composition in which the composition contains from 25 to 300 parts by weight based on the base silanol or vinyl containing diorganopolysiloxane polymer of a boron compound or boron powder as the neutron absorbing ingredient. An especially useful boron compound in this application is boron carbide.

  13. Novel Nanocomposite Structures as Active and Passive Barrier Materials

    DTIC Science & Technology

    2010-06-01

    during the course of this ARO-funded project. The development of a novel polymer material based on a diol-functionalized room-temperature ionic liquid ...material based on a diol-functionalized room- temperature ionic liquid (RTIL) monomer led to fabrication of membranes, which were tested for their...stimulant vapor. Technical Report A polymerizable room-temperature ionic liquid (4, Figure 1) was chosen as the starting material for making poly(RTIL

  14. Optimization of reading conditions for flat panel displays.

    PubMed

    Thomas, J A; Chakrabarti, K; Kaczmarek, R V; Maslennikov, A; Mitchell, C A; Romanyukha, A

    2006-06-01

    Task Group 18 (TG 18) of the American Association of Physicists in Medicine has developed guidelines for Assessment of Display Performance for Medical Imaging Systems. In this document, a method for determination of the maximum room lighting for displays is suggested. It is based on luminance measurements of a black target displayed on each display device at different room illuminance levels. Linear extrapolation of the above luminance measurements vs. room illuminance allows one to determine diffuse and specular reflection coefficients. TG 18 guidelines have established recommended maximum room lighting. It is based on the characterization of the display by its minimum and maximum luminance and the description of room by diffuse and specular coefficients. We carried out these luminance measurements for three selected displays to determine their optimum viewing conditions: one cathode ray tube and two flat panels. We found some problems with the application of the TG 18 guidelines to optimize viewing conditions for IBM T221 flat panels. Introduction of the requirement for minimum room illuminance allows a more accurate determination of the optimal viewing conditions (maximum and minimum room illuminance) for IBM flat panels. It also addresses the possible loss of contrast in medical images on flat panel displays because of the effect of nonlinearity in the dependence of luminance on room illuminance at low room lighting.

  15. Magnet system optimization for segmented adaptive-gap in-vacuum undulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kitegi, C., E-mail: ckitegi@bnl.gov; Chubar, O.; Eng, C.

    2016-07-27

    Segmented Adaptive Gap in-vacuum Undulator (SAGU), in which different segments have different gaps and periods, promises a considerable spectral performance gain over a conventional undulator with uniform gap and period. According to calculations, this gain can be comparable to the gain achievable with a superior undulator technology (e.g. a room-temperature in-vacuum hybrid SAGU would perform as a cryo-cooled hybrid in-vacuum undulator with uniform gap and period). However, for reaching the high spectral performance, SAGU magnetic design has to include compensation of kicks experienced by the electron beam at segment junctions because of different deflection parameter values in the segments. Wemore » show that such compensation to large extent can be accomplished by using a passive correction, however, simple correction coils are nevertheless required as well to reach perfect compensation over a whole SAGU tuning range. Magnetic optimizations performed with Radia code, and the resulting undulator radiation spectra calculated using SRW code, demonstrating a possibility of nearly perfect correction, are presented.« less

  16. Vibrational and thermodynamic properties of β-HMX: a first-principles investigation.

    PubMed

    Wu, Zhongqing; Kalia, Rajiv K; Nakano, Aiichiro; Vashishta, Priya

    2011-05-28

    Thermodynamic properties of β-HMX crystal are investigated using the quasi-harmonic approximation and density functional theory within the local density approximation (LDA), generalized gradient approximation (GGA), and GGA + empirical van der Waals (vdW) correction. It is found that GGA well describes the thermal expansion coefficient and heat capacity but fails to produce correct bulk modulus and equilibrium volume. The vdW correction improves the bulk modulus and volume, but worsens the thermal expansion coefficient and heat capacity. In contrast, LDA describes all thermodynamic properties with reasonable accuracy, and overall is a good exchange-correlation functional for β-HMX molecular crystal. The results also demonstrate significant contributions of phonons to the equation of state. The static calculation of equilibrium volume for β-HMX differs from the room-temperature value incorporating lattice vibrations by over 5%. Therefore, for molecular crystals, it is essential to include phonon contributions when calculated equation of state is compared with experimental data at ambient condition. © 2011 American Institute of Physics

  17. Giant switchable Rashba effect in oxide heterostructures

    DOE PAGES

    Zhong, Zhicheng; Si, Liang; Zhang, Qinfang; ...

    2015-03-01

    One of the most fundamental phenomena and a reminder of the electron’s relativistic nature is the Rashba spin splitting for broken inversion symmetry. Usually this splitting is a tiny relativistic correction. Interfacing ferroelectric BaTiO₃ and a 5d (or 4d) transition metal oxide with a large spin-orbit coupling, Ba(Os,Ir,Ru)O₃, we show that giant Rashba spin splittings are indeed possible and even controllable by an external electric field. Based on density functional theory and a microscopic tight binding understanding, we conclude that the electric field is amplified and stored as a ferroelectric Ti-O distortion which, through the network of oxygen octahedra, inducesmore » a large (Os,Ir,Ru)-O distortion. The BaTiO₃/Ba(Os,Ru,Ir)O₃ heterostructure is hence the ideal test station for switching and studying the Rashba effect and allows applications at room temperature.« less

  18. Repulsive force support system feasibility study

    NASA Technical Reports Server (NTRS)

    Boom, R. W.; Abdelsalam, M. K.; Eyssa, Y. M.; Mcintosh, G. E.

    1987-01-01

    A new concept in magnetic levitation and control is introduced for levitation above a plane. A set of five vertical solenoid magnets mounted flush below the plane supports and controls the model in five degrees of freedom. The compact system of levitation coils is contained in a space 2.4 m (96 in) diameter by 1 m (40 in) deep with the top of the levitation system 0.9 m (36 in) below the center line of the suspended model. The levitated model has a permanent magnet core held in position by the five parallel superconductive solenoids symmetrically located in a circle. The control and positioning system continuously corrects for model position in five dimensions using computer current pulses superimposed on the levitation coil base currents. The conceptual designs include: superconductive and Nd-Fe-B permanent magnet model cores and levitation solenoids of either superconductive, cryoresistive, or room temperature windings.

  19. Air-stable superparamagnetic metal nanoparticles entrapped in graphene oxide matrix

    NASA Astrophysics Data System (ADS)

    Tuček, Jiří; Sofer, Zdeněk; Bouša, Daniel; Pumera, Martin; Holá, Kateřina; Malá, Aneta; Poláková, Kateřina; Havrdová, Markéta; Čépe, Klára; Tomanec, Ondřej; Zbořil, Radek

    2016-09-01

    Superparamagnetism is a phenomenon caused by quantum effects in magnetic nanomaterials. Zero-valent metals with diameters below 5 nm have been suggested as superior alternatives to superparamagnetic metal oxides, having greater superspin magnitudes and lower levels of magnetic disorder. However, synthesis of such nanometals has been hindered by their chemical instability. Here we present a method for preparing air-stable superparamagnetic iron nanoparticles trapped between thermally reduced graphene oxide nanosheets and exhibiting ring-like or core-shell morphologies depending on iron concentration. Importantly, these hybrids show superparamagnetism at room temperature and retain it even at 5 K. The corrected saturation magnetization of 185 Am2 kg-1 is among the highest values reported for iron-based superparamagnets. The synthetic concept is generalized exploiting functional groups of graphene oxide to stabilize and entrap cobalt, nickel and gold nanoparticles, potentially opening doors for targeted delivery, magnetic separation and imaging applications.

  20. Air-stable superparamagnetic metal nanoparticles entrapped in graphene oxide matrix.

    PubMed

    Tuček, Jiří; Sofer, Zdeněk; Bouša, Daniel; Pumera, Martin; Holá, Kateřina; Malá, Aneta; Poláková, Kateřina; Havrdová, Markéta; Čépe, Klára; Tomanec, Ondřej; Zbořil, Radek

    2016-09-15

    Superparamagnetism is a phenomenon caused by quantum effects in magnetic nanomaterials. Zero-valent metals with diameters below 5 nm have been suggested as superior alternatives to superparamagnetic metal oxides, having greater superspin magnitudes and lower levels of magnetic disorder. However, synthesis of such nanometals has been hindered by their chemical instability. Here we present a method for preparing air-stable superparamagnetic iron nanoparticles trapped between thermally reduced graphene oxide nanosheets and exhibiting ring-like or core-shell morphologies depending on iron concentration. Importantly, these hybrids show superparamagnetism at room temperature and retain it even at 5 K. The corrected saturation magnetization of 185 Am(2) kg(-1) is among the highest values reported for iron-based superparamagnets. The synthetic concept is generalized exploiting functional groups of graphene oxide to stabilize and entrap cobalt, nickel and gold nanoparticles, potentially opening doors for targeted delivery, magnetic separation and imaging applications.

  1. Air-stable superparamagnetic metal nanoparticles entrapped in graphene oxide matrix

    PubMed Central

    Tuček, Jiří; Sofer, Zdeněk; Bouša, Daniel; Pumera, Martin; Holá, Kateřina; Malá, Aneta; Poláková, Kateřina; Havrdová, Markéta; Čépe, Klára; Tomanec, Ondřej; Zbořil, Radek

    2016-01-01

    Superparamagnetism is a phenomenon caused by quantum effects in magnetic nanomaterials. Zero-valent metals with diameters below 5 nm have been suggested as superior alternatives to superparamagnetic metal oxides, having greater superspin magnitudes and lower levels of magnetic disorder. However, synthesis of such nanometals has been hindered by their chemical instability. Here we present a method for preparing air-stable superparamagnetic iron nanoparticles trapped between thermally reduced graphene oxide nanosheets and exhibiting ring-like or core-shell morphologies depending on iron concentration. Importantly, these hybrids show superparamagnetism at room temperature and retain it even at 5 K. The corrected saturation magnetization of 185 Am2 kg–1 is among the highest values reported for iron-based superparamagnets. The synthetic concept is generalized exploiting functional groups of graphene oxide to stabilize and entrap cobalt, nickel and gold nanoparticles, potentially opening doors for targeted delivery, magnetic separation and imaging applications. PMID:27628898

  2. Testing Moderating Detection Systems with {sup 252}Cf-Based Reference Neutron Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertel, Nolan E.; Sweezy, Jeremy; Sauber, Jeremiah S.

    Calibration measurements were carried out on a probe designed to measure ambient dose equivalent in accordance with ICRP Pub 60 recommendations. It consists of a cylindrical {sup 3}He proportional counter surrounded by a 25-cm-diameter spherical polyethylene moderator. Its neutron response is optimized for dose rate measurements of neutrons between thermal energies and 20 MeV. The instrument was used to measure the dose rate in four separate neutron fields: unmoderated {sup 252}Cf, D{sub 2}O-moderated {sup 252}Cf, polyethylene-moderated {sup 252}Cf, and WEP neutron howitzer with {sup 252}Cf at its center. Dose equivalent measurements were performed at source-detector centerline distances from 50 tomore » 200 cm. The ratio of air-scatter- and room-return-corrected ambient dose equivalent rates to ambient dose equivalent rates calculated with the code MCNP are tabulated.« less

  3. Interior of display area (room 101), looking south towards TV ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior of display area (room 101), looking south towards TV control panel room (room 139) at far left corner. The stairway leads to the commander's quarters and the senior battle viewing bridge at top right. Control and communication consoles at the right - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  4. [Simulation-based training and OR apprenticeship for medical students : A prospective, randomized, single-blind study of clinical skills].

    PubMed

    Ott, T; Schmidtmann, I; Limbach, T; Gottschling, P F; Buggenhagen, H; Kurz, S; Pestel, G

    2016-11-01

    Simulation-based training (SBT) has developed into an established method of medical training. Studies focusing on the education of medical students have used simulation as an evaluation tool for defined skills. A small number of studies provide evidence that SBT improves medical students' skills in the clinical setting. Moreover, they were strictly limited to a few areas, such as the diagnosis of heart murmurs or the correct application of cricoid pressure. Other studies could not prove adequate transferability from the skills gained in SBT to the patient site. Whether SBT has an effect on medical students' skills in anesthesiology in the clinical setting is controversial. To explore this issue, we designed a prospective, randomized, single-blind trial that was integrated into the undergraduate anesthesiology curriculum of our department during the second year of the clinical phase of medical school. This study intended to explore the effect of SBT on medical students within the mandatory undergraduate anesthesiology curriculum of our department in the operating room with respect to basic skills in anesthesiology. After obtaining ethical approval, the participating students of the third clinical semester were randomized into two groups: the SIM-OR group was trained by a 225 min long SBT in basic skills in anesthesiology before attending the operating room (OR) apprenticeship. The OR-SIM group was trained after the operating room apprenticeship by SBT. During SBT the students were trained in five clinical skills detailed below. Further, two clinical scenarios were simulated using a full-scale simulator. The students had to prepare the patient and perform induction of anesthesia, including bag-mask ventilation after induction in scenario 1 and rapid sequence induction in scenario 2. Using the five-point Likert scale, five defined skills were evaluated at defined time points during the study period. 1) application of the safety checklist, 2) application of basic patient monitoring, 3) establishment of intravenous access, 4) bag-and-mask ventilation, and 5) adjustment of ventilatory parameters after the patients' airways were secured. A cumulative score of 5 points was defined as the best and a cumulative score of 25 as the worst rating for a defined time point. The primary endpoint was the cumulative score after day 1 in the operating room apprenticeship and the difference in cumulative scores from days 1 to 4. Our hypothesis was that the SIM-OR group would achieve a better score after day 1 in the operating room apprenticeship and would gain a larger increase in score from day 1 to day 4 than the OR-SIM group. 73 students were allocated to the OR-SIM group and 70 students to the SIM-OR group. There was no significant difference between the two groups after day 1 of the operating room apprenticeship and no difference in increase of the cumulative score from day 1 to day 4 (median of cumulative score on day 1: 'SIM-OR' 11.2 points vs. 'OR-SIM' 14.6 points; p = 0.067; median of difference from day 1 to day 4: 'SIM-OR' -3.7 vs. 'OR-SIM' -6.4; p = 0.110). With the methods applied, this study could not prove that 225 min of SBT before the operating room apprenticeship increased the medical students' clinical skills as evaluated in the operating room. Secondary endpoints indicate that medical students have better clinical skills at the end of the entire curriculum when they have been trained through SBT before the operating room apprenticeship. However, the authors believe that simulator training has a positive impact on students' acquisition of procedural and patient safety skills, even if the methods applied in this study may not mirror this aspect sufficiently.

  5. The pros and cons of intraoperative CT scan in evaluation of deep brain stimulation lead implantation: A retrospective study

    PubMed Central

    Servello, Domenico; Zekaj, Edvin; Saleh, Christian; Pacchetti, Claudio; Porta, Mauro

    2016-01-01

    Background: Deep brain stimulation (DBS) is an established therapy for movement disorders, such as Parkinson's disease (PD), dystonia, and tremor. The efficacy of DBS depends on the correct lead positioning. The commonly adopted postoperative radiological evaluation is performed with computed tomography (CT) scan and/or magnetic resonance imaging (MRI). Methods: We conducted a retrospective study on 202 patients who underwent DBS from January 2009 to October 2013. DBS indications were PD, progressive supranuclear palsy, tremor, dystonia, Tourette syndrome, obsessive compulsive disorder, depression, and Huntington's disease. Preoperatively, all patients underwent brain MRI and brain CT scan with the stereotactic frame positioned. The lead location was confirmed intraoperatively with CT. The CT images were subsequently transferred to the Stealth Station Medtronic and merged with the preoperative planning. On the first or second day after, implantation we performed a brain MRI to confirm the correct position of the lead. Results: In 14 patients, leads were in suboptimal position after intraoperative CT scan positioning. The cases with alteration in the Z-axis were corrected immediately under fluoroscopic guidance. In all the 14 patients, an immediate repositioning was done. Conclusions: Based on our data, intraoperative CT scan is fast, safe, and a useful tool in the evaluation of the position of the implanted lead. It also reduces the patient's discomfort derived from the transfer of the patient from the operating room to the radiological department. However, intraoperative CT should not be considered as a substitute for postoperative MRI. PMID:27583182

  6. Compensating for Effects of Humidity on Electronic Noses

    NASA Technical Reports Server (NTRS)

    Homer, Margie; Ryan, Margaret A.; Manatt, Kenneth; Zhou, Hanying; Manfreda, Allison

    2004-01-01

    A method of compensating for the effects of humidity on the readouts of electronic noses has been devised and tested. The method is especially appropriate for use in environments in which humidity is not or cannot be controlled for example, in the vicinity of a chemical spill, which can be accompanied by large local changes in humidity. Heretofore, it has been common practice to treat water vapor as merely another analyte, the concentration of which is determined, along with that of the other analytes, in a computational process based on deconvolution. This practice works well, but leaves room for improvement: changes in humidity can give rise to large changes in electronic-nose responses. If corrections for humidity are not made, the large humidity-induced responses may swamp smaller responses associated with low concentrations of analytes. The present method offers an improvement. The underlying concept is simple: One augments an electronic nose with a separate humidity and a separate temperature sensor. The outputs of the humidity and temperature sensors are used to generate values that are subtracted from the readings of the other sensors in an electronic nose to correct for the temperature-dependent contributions of humidity to those readings. Hence, in principle, what remains after corrections are the contributions of the analytes only. Laboratory experiments on a first-generation electronic nose have shown that this method is effective and improves the success rate of identification of analyte/ water mixtures. Work on a second-generation device was in progress at the time of reporting the information for this article.

  7. Study on Incompatibility of Traditional Chinese Medicine: Evidence from Formula Network, Chemical Space, and Metabolism Room

    PubMed Central

    Zhang, Xiao-Dong; Wu, Hong-Ying; Jin, Jin; Yu, Guang-Yun; He, Xin; Wang, Hao; Shen, Xiu; Zhou, Ze-Wei; Liu, Pei-Xun; Fan, Sai-Jun

    2013-01-01

    A traditional Chinese medicine (TCM) formula network including 362 TCM formulas was built by using complex network methodologies. The properties of this network were analyzed including network diameter, average distance, clustering coefficient, and average degree. Meanwhile, we built a TCM chemical space and a TCM metabolism room under the theory of chemical space. The properties of chemical space and metabolism room were calculated and analyzed. The properties of the medicine pairs in “eighteen antagonisms and nineteen mutual inhibitors,” an ancient rule for TCM incompatibility, were studied based on the TCM formula network, chemical space, and metabolism room. The results showed that the properties of these incompatible medicine pairs are different from those of the other TCM based on the analysis of the TCM formula network, chemical space, and metabolism room. The lines of evidence derived from our work demonstrated that the ancient rule of TCM incompatibility, “eighteen antagonisms and nineteen mutual inhibitors,” is probably scientifically based. PMID:24369478

  8. Definition of yearly emission factor of dust and greenhouse gases through continuous measurements in swine husbandry

    NASA Astrophysics Data System (ADS)

    Costa, Annamaria; Guarino, Marcella

    The object of this study was to develop an accurate estimation method to evaluate the contribution of the various compartments of swine husbandry to dust and GHG (greenhouse gases, CO 2, CH 4 and N 2O) emission into the atmosphere during one year of observation. A weaning, a gestation, a farrowing and a fattening room in an intensive pig house were observed in three different periods (Autumn-Winter, Springtime and Summer, monitoring at least 60% of each period (20% at the beginning, in the middle and at the end) of each cycle). During monitoring, live weight, average live weight gain, number of animals and its variation, type of feed and feeding time were taken into account to evaluate their influence on PM 10, or the fraction of suspended particulate matter with an aerodynamic diameter less than or equal to 10 μm [Emission Inventory Guidebook, 2007. B1100 Particle Emissions from Animal Husbandry Activities. Available from: (accessed October 2008)] and to define GHG emission. The selected piggery had a ventilation control system using a free running impeller to monitor continuously real-time environmental and management parameters with an accuracy of 5%. PM 10 concentration was monitored by a sampler (Haz Dust EPAM 5000), either continuously or through traditional gravimetric technique, and the mean value of dust amount collected on the membranes was utilized as a correction factor to be applied to continuously collected data. PM 10 concentration amount incoming from inlets was removed from PM 10 emission calculation, to estimate the real contribution of pig house dust pollution into atmosphere. Mean yearly emission factor of PM 10 was measured in 2 g d -1 LU -1 for the weaning room, 0.09 g d -1 LU -1 for the farrowing room, 2.59 g d -1 LU -1 for the fattening room and 1.23 g d -1 LU -1 for the gestation room. The highest PM 10 concentration and emission per LU was recorded in the fattening compartment while the lowest value was recorded in the farrowing room. CO 2, CH 4 and N 2O concentrations were continuously measured in the exhaust ducts using an infrared photoacoustic detector IPD (Brüel & Kjaer, Multi-gas Monitor Type 1302, Multipoint Sampler and Doser Type 1303) sampling data every 15 min, for the 60% of the cycles. Yearly emission factor for CO 2 was measured in 5997 g d -1 LU -1 for the weaning room, 1278 g d -1 LU -1 for the farrowing room, 13,636 g d -1 LU -1 for the fattening room and 8851 g d -1 LU -1 for the gestation room. Yearly emission factor for CH 4 was measured in 24.57 g d -1 LU -1 for the weaning room, 4.68 g d -1 LU -1 for the farrowing room, 189.82 g d -1 LU -1 for the fattening room and 132.12 g d -1 LU -1 for the gestation room. Yearly emission factor for N 2O was measured in 3.62 g d -1 LU -1 for the weaning room, 0.66 g d -1 LU -1 for the farrowing room, 3.26 g d -1 LU -1 for the fattening room and 2.72 g d -1 LU -1 for the gestation room.

  9. 14. Interior view of vestibule separating rehabilitation space, testing room, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Interior view of vestibule separating rehabilitation space, testing room, and corridor to workout room looking into corridor; near center of occupied portion; view to southeast. - Ellsworth Air Force Base, Mess & Administration Building, 2279 Risner Drive, Blackhawk, Meade County, SD

  10. Conditions for extreme sensitivity of protein diffusion in membranes to cell environments

    PubMed Central

    Tserkovnyak, Yaroslav; Nelson, David R.

    2006-01-01

    We study protein diffusion in multicomponent lipid membranes close to a rigid substrate separated by a layer of viscous fluid. The large-distance, long-time asymptotics for Brownian motion are calculated by using a nonlinear stochastic Navier–Stokes equation including the effect of friction with the substrate. The advective nonlinearity, neglected in previous treatments, gives only a small correction to the renormalized viscosity and diffusion coefficient at room temperature. We find, however, that in realistic multicomponent lipid mixtures, close to a critical point for phase separation, protein diffusion acquires a strong power-law dependence on temperature and the distance to the substrate H, making it much more sensitive to cell environment, unlike the logarithmic dependence on H and very small thermal correction away from the critical point. PMID:17008402

  11. Recent Progress in Thallium Bromide Gamma-Ray Spectrometer Development

    NASA Astrophysics Data System (ADS)

    Kim, Hadong; Kargar, Alireza; Cirignano, Leonard; Churilov, Alexei; Ciampi, Guido; Higgins, William; Olschner, Fred; Shah, Kanai

    2012-02-01

    In recent years, progress in processing and crystal growth methods have led to a significant increase in the mobility-lifetime product of electrons in thallium bromide (TlBr). This has enabled single carrier collection devices with thickness greater than 1-cm to be fabricated. In this paper we report on our latest results from pixellated devices with depth correction as well as our initial results with Frisch collar devices. After applying depth corrections, energy resolution of approximately 2% (FWHM at 662 keV) was obtained from a 13-mm thick TlBr array operated at -18°C and under continuous bias and irradiation for more than one month. Energy resolution of 2.4% was obtained at room temperature with an 8.4-mm thick TlBr Frisch collar device.

  12. 112. VIEW OF SOUTH SIDE OF MECHANICAL AND ELECTRICAL ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    112. VIEW OF SOUTH SIDE OF MECHANICAL AND ELECTRICAL ROOM (110), LSB (BLDG. 770). VEHICLE MECHANICAL SYSTEMS ROOM (111) AND PNEUMATIC SUPPLY PANEL VISIBLE AT SOUTH END OF MECHANICAL AND ELECTRICAL ROOM (110). PAYLOAD CABLE DISTRIBUTION BOX ON LEFT OF PHOTO, FACING WEST. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  13. 116. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (206), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (206), LSB (BLDG. 751), WITH CABINETS ON EAST SIDE OF ROOM FACING WEST. THE ROW OF CABINETS ON EAST SIDE OF ROOM INCLUDES LEFT TO RIGHT: CABLE DISTRIBUTION UNITS, AUTOPILOT CONTROLS, AND POWER DISTRIBUTION UNITS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  14. 113. VIEW OF NORTH SIDE OF MECHANICAL AND ELECTRICAL ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    113. VIEW OF NORTH SIDE OF MECHANICAL AND ELECTRICAL ROOM (110), LSB (BLDG. 770). QUALITY ASSURANCE ROOM (106A) ON RIGHT SIDE OF PHOTO; CABLE TRAYS OVERHEAD AT TOP; STAIRS TO LSB (BLDG. 770) ADDITION (ROOMS 117 THROUGH 120) IN CENTER OF PHOTO. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  15. West wall, display area (room 101), view 1 of 4: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    West wall, display area (room 101), view 1 of 4: southwest corner, showing stairs to commander's quarters and viewing bridge, windows to controller's room (room 102), south end of control consoles, and holes in pedestal floor for computer equipment cables (tape drive I/O?) - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  16. Thermostructural Evaluation of Four Infrared Seeker Dome Materials. Part 2. Thermal and Mechanical Properties

    DTIC Science & Technology

    1985-04-01

    Selenide (ZnSe) and Zinc Sulphide (ZnS). The mechanical properties used in the evaluation include tension, compression and flexure at room temperature...communicates with the atmosphere through a mercury column in order that the change in volume can be read directly in a burette. 17...The correction of the basket is subtracted from the measured mercury displacement and the result used to calculate specimen en~halpy above 32 ’F. The

  17. Electron mobility in mercury cadmium telluride

    NASA Technical Reports Server (NTRS)

    Patterson, James D.

    1988-01-01

    A previously developed program, which includes all electronic interactions thought to be important, does not correctly predict the value of electron mobility in mercury cadmium telluride particularly near room temperature. Part of the reason for this discrepancy is thought to be the way screening is handled. It seems likely that there are a number of contributors to errors in the calculation. The objective is to survey the calculation, locate reasons for differences between experiment and calculation, and suggest improvements.

  18. Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy.

    PubMed

    Bruza, Petr; Gollub, Sarah L; Andreozzi, Jacqueline M; Tendler, Irwin I; Williams, Benjamin B; Jarvis, Lesley A; Gladstone, David J; Pogue, Brian W

    2018-05-02

    The purpose of this study was to measure surface dose by remote time-gated imaging of plastic scintillators. A novel technique for time-gated, intensified camera imaging of scintillator emission was demonstrated, and key parameters influencing the signal were analyzed, including distance, angle and thickness. A set of scintillator samples was calibrated by using thermo-luminescence detector response as reference. Examples of use in total skin electron therapy are described. The data showed excellent room light rejection (signal-to-noise ratio of scintillation SNR  ≈  470), ideal scintillation dose response linearity, and 2% dose rate error. Individual sample scintillation response varied by 7% due to sample preparation. Inverse square distance dependence correction and lens throughput error (8% per meter) correction were needed. At scintillator-to-source angle and observation angle  <50°, the radiant energy fluence error was smaller than 1%. The achieved standard error of the scintillator cumulative dose measurement compared to the TLD dose was 5%. The results from this proof-of-concept study documented the first use of small scintillator targets for remote surface dosimetry in ambient room lighting. The measured dose accuracy renders our method to be comparable to thermo-luminescent detector dosimetry, with the ultimate realization of accuracy likely to be better than shown here. Once optimized, this approach to remote dosimetry may substantially reduce the time and effort required for surface dosimetry.

  19. Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy

    NASA Astrophysics Data System (ADS)

    Bruza, Petr; Gollub, Sarah L.; Andreozzi, Jacqueline M.; Tendler, Irwin I.; Williams, Benjamin B.; Jarvis, Lesley A.; Gladstone, David J.; Pogue, Brian W.

    2018-05-01

    The purpose of this study was to measure surface dose by remote time-gated imaging of plastic scintillators. A novel technique for time-gated, intensified camera imaging of scintillator emission was demonstrated, and key parameters influencing the signal were analyzed, including distance, angle and thickness. A set of scintillator samples was calibrated by using thermo-luminescence detector response as reference. Examples of use in total skin electron therapy are described. The data showed excellent room light rejection (signal-to-noise ratio of scintillation SNR  ≈  470), ideal scintillation dose response linearity, and 2% dose rate error. Individual sample scintillation response varied by 7% due to sample preparation. Inverse square distance dependence correction and lens throughput error (8% per meter) correction were needed. At scintillator-to-source angle and observation angle  <50°, the radiant energy fluence error was smaller than 1%. The achieved standard error of the scintillator cumulative dose measurement compared to the TLD dose was 5%. The results from this proof-of-concept study documented the first use of small scintillator targets for remote surface dosimetry in ambient room lighting. The measured dose accuracy renders our method to be comparable to thermo-luminescent detector dosimetry, with the ultimate realization of accuracy likely to be better than shown here. Once optimized, this approach to remote dosimetry may substantially reduce the time and effort required for surface dosimetry.

  20. Bio-Kil, a nano-based disinfectant, reduces environmental bacterial burden and multidrug-resistant organisms in intensive care units.

    PubMed

    Lee, Wen-Sen; Hsieh, Tai-Chin; Shiau, Justine C; Ou, Tsong-Yih; Chen, Fu-Lun; Liu, Yu-Hsin; Yen, Muh-Yong; Hsueh, Po-Ren

    2017-10-01

    This prospective before-after study was intended to investigate the effect of Bio-Kil on reducing environmental bacterial burden and healthcare-associated infections (HAIs) in intensive care units (ICUs) at the Municipal Wan-Fang Hospital, Taipei, Taiwan in 2014. Four rooms in the medical and surgical ICUs were investigated and designated as study rooms (n = 2) or control rooms (n = 2). Routine disinfection was performed during the pre-intervention period in both room types. Bio-Kil was applied to the fomites and surroundings of the study rooms during the intervention period. Total bacterial burden and proportion of colonization of fomites and surroundings by multidrug-resistance organisms (MDROs) were determined before and after the intervention. The demographic characteristics, underlying conditions, and clinical outcomes of patients were analyzed. After application of Bio-Kil, the bacterial burden declined in both groups, although the reduction was greater in the study rooms as compared with the control rooms (p = 0.001). During the pre-intervention period, 16 patients were admitted to control rooms and 18 patients to study rooms. After the intervention, 22 patients were admitted to control rooms and 21 patients to study rooms. The number of cases of new-onset sepsis declined in the intervention group (from 33% to 23.8%), but increased in the control group (from 25% to 40.9%); however, there was no significant difference in incidence of new-onset sepsis between the study and control rooms after intervention. Application of Bio-Kil reduced the environmental bacterial burden and MDROs in ICUs. Further studies are needed to evaluate the efficacy of this nanotechnology-based disinfectant in reducing HAIs. Copyright © 2016. Published by Elsevier B.V.

  1. Interference effects in phased beam tracing using exact half-space solutions.

    PubMed

    Boucher, Matthew A; Pluymers, Bert; Desmet, Wim

    2016-12-01

    Geometrical acoustics provides a correct solution to the wave equation for rectangular rooms with rigid boundaries and is an accurate approximation at high frequencies with nearly hard walls. When interference effects are important, phased geometrical acoustics is employed in order to account for phase shifts due to propagation and reflection. Error increases, however, with more absorption, complex impedance values, grazing incidence, smaller volumes and lower frequencies. Replacing the plane wave reflection coefficient with a spherical one reduces the error but results in slower convergence. Frequency-dependent stopping criteria are then applied to avoid calculating higher order reflections for frequencies that have already converged. Exact half-space solutions are used to derive two additional spherical wave reflection coefficients: (i) the Sommerfeld integral, consisting of a plane wave decomposition of a point source and (ii) a line of image sources located at complex coordinates. Phased beam tracing using exact half-space solutions agrees well with the finite element method for rectangular rooms with absorbing boundaries, at low frequencies and for rooms with different aspect ratios. Results are accurate even for long source-to-receiver distances. Finally, the crossover frequency between the plane and spherical wave reflection coefficients is discussed.

  2. Temperature corrections in routine spirometry.

    PubMed Central

    Cramer, D; Peacock, A; Denison, D

    1984-01-01

    Forced expiratory volume (FEV1) and forced vital capacity (FVC) were measured in nine normal subjects with three Vitalograph and three rolling seal spirometers at three different ambient temperatures (4 degrees C, 22 degrees C, 32 degrees C). When the results obtained with the rolling seal spirometer were converted to BTPS the agreement between measurements in the three environments improved, but when the Vitalograph measurements obtained in the hot and cold rooms were converted an error of up to 13% was introduced. The error was similar whether ambient or spirometer temperatures were used to make the conversion. In an attempt to explain the behaviour of the Vitalograph spirometers the compliance of their bellows was measured at the three temperatures. It was higher at the higher temperature (32 degrees C) and lower at the lower temperature (4 degrees C) than at the normal room temperature. These changes in instrument compliance could account for the differences in measured values between the two types of spirometer. It is concluded that the ATPS-BTPS conversion is valid and necessary for measurements made with rolling seal spirometers, but can cause substantial error if it is used for Vitalograph measurements made under conditions other than normal room temperature. PMID:6495245

  3. A case of a power failure in the operating room.

    PubMed

    Yasny, Jeffrey; Soffer, Robert

    2005-01-01

    In the operating room, safely administering anesthesia amidst a major power failure can instantly present one with a formidable challenge. A case is presented involving a 23-year-old healthy woman who underwent a complex oral and maxillofacial surgery to correct a dentofacial deformity. Three hours into the case and with the patient's maxilla downfractured, the overhead surgical lights blacked out, and there was an apparent loss of the anesthesia machine's ability to function. Providing adequate oxygenation, ventilation, anesthesia levels, monitoring of vital signs, and transportation of the patient were some of the challenges faced, and the response to this unexpected event is recounted. The importance of one's familiarity with an anesthesia machine's backup battery supply, routinely checking machinery, ensuring that appropriate and sufficient supplies are readily available, exercising calm leadership with clear communication, and formulating a clear plan with backup alternatives are discussed. Various recommendations are proposed with respect to the preparation for and the prevention of a power failure in the operating room. This report's account of events is aimed to "shed some light" on this topic, serve as a check of one's own preparedness, and facilitate the optimal management of a similarly unexpected incident.

  4. 86. VIEW OF AUTOPILOT ROOM LOOKING WEST FROM CENTER OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    86. VIEW OF AUTOPILOT ROOM LOOKING WEST FROM CENTER OF ROOM. IBM PERSONAL COMPUTER FOR SLC-3W AUTOPILOT FUNCTIONS IN SOUTHWEST CORNER (LEFT). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  5. Correcting scan-to-scan response variability for a radiochromic film-based reference dosimetry system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, David, E-mail: rcfilmconsulting@gmail.com; Devic, Slobodan

    Purpose: In radiochromic film dosimetry systems, measurements are usually obtained from film images acquired on a CCD-based flatbed scanner. The authors investigated factors affecting scan-to-scan response variability leading to increased dose measurement uncertainty. Methods: The authors used flatbed document scanners to repetitively scan EBT3 radiochromic films exposed to doses 0–1000 cGy, together with three neutral density filters and three blue optical filters. Scanning was performed under two conditions: scanner lid closed and scanner lid opened/closed between scans. The authors also placed a scanner in a cold room at 9 °C and later in a room at 22 °C and scanned EBT3 filmsmore » to explore temperature effects. Finally, the authors investigated the effect of altering the distance between the film and the scanner’s light source. Results: Using a measurement protocol to isolate the contribution of the CCD and electronic circuitry of the scanners, the authors found that the standard deviation of response measurements for the EBT3 film model was about 0.17% for one scanner and 0.09% for the second. When the lid of the first scanner was opened and closed between scans, the average scan-to-scan difference of responses increased from 0.12% to 0.27%. Increasing the sample temperature during scanning changed the RGB response values by about −0.17, −0.14, and −0.05%/°C, respectively. Reducing the film-to-light source distance increased the RBG response values about 1.1, 1.3, and 1.4%/mm, respectively. The authors observed that films and film samples were often not flat with some areas up to 8 mm away from the scanner’s glass window. Conclusions: In the absence of measures to deal with the response irregularities, each factor the authors investigated could lead to dose uncertainty >2%. Those factors related to the film-to-light source distance could be particularly impactful since the authors observed many instances where the curl of film samples had the potential to cause dose uncertainty in excess of 5%. Two expedients will eliminate the uncertainties: a transparent sheet (preferably glass) placed over the scanned film keeps the film-to-light source distance constant, and an EBT3 reference film included in all scans provides correction factors for measured response values.« less

  6. An ab initio variationally computed room-temperature line list for (32)S(16)O3.

    PubMed

    Underwood, Daniel S; Tennyson, Jonathan; Yurchenko, Sergei N

    2013-07-07

    Ab initio potential energy and dipole moment surfaces are computed for sulfur trioxide (SO3) at the CCSD(T)-F12b level of theory with appropriate triple-zeta basis sets. The analytical representations of these surfaces are used, with a slight correction, to compute pure rotational and rotation-vibration spectra of (32)S(16)O3 using the variational nuclear motion program TROVE. The calculations considered transitions in the region 0-4000 cm(-1) with rotational states up to J = 85. The resulting line list of 174,674,257 transitions is appropriate for modelling room temperature (32)S(16)O3 spectra. Good agreement is found with the observed infrared absorption spectra and the calculations are used to place the measured relative intensities on an absolute scale. A list of 10,878 experimental transitions is provided in a form suitable for inclusion in standard atmospheric and planetary spectroscopic databases.

  7. 7. CONTROL AND EQUIPMENT ROOM INTERIOR. Looking to southwest corner ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. CONTROL AND EQUIPMENT ROOM INTERIOR. Looking to southwest corner and entrance to cable tunnel. - Edwards Air Force Base, South Base Sled Track, Firing Control Blockhouse, South of Sled Track at east end, Lancaster, Los Angeles County, CA

  8. 45. Communication equipment room, cable air dryer on left, motorola ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. Communication equipment room, cable air dryer on left, motorola base station (vhf) at right, looking southwest - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  9. SU-F-T-142: An Analytical Model to Correct the Aperture Scattered Dose in Clinical Proton Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, B; Liu, S; Zhang, T

    2016-06-15

    Purpose: Apertures or collimators are used to laterally shape proton beams in double scattering (DS) delivery and to sharpen the penumbra in pencil beam (PB) delivery. However, aperture-scattered dose is not included in the current dose calculations of treatment planning system (TPS). The purpose of this study is to provide a method to correct the aperture-scattered dose based on an analytical model. Methods: A DS beam with a non-divergent aperture was delivered using a single-room proton machine. Dose profiles were measured with an ion-chamber scanning in water and a 2-D ion chamber matrix with solid-water buildup at various depths. Themore » measured doses were considered as the sum of the non-contaminated dose and the aperture-scattered dose. The non-contaminated dose was calculated by TPS and subtracted from the measured dose. Aperture scattered-dose was modeled as a 1D Gaussian distribution. For 2-D fields, to calculate the scatter-dose from all the edges of aperture, a sum of weighted distance was used in the model based on the distance from calculation point to aperture edge. The gamma index was calculated between the measured and calculated dose with and without scatter correction. Results: For a beam with range of 23 cm and aperture size of 20 cm, the contribution of the scatter horn was ∼8% of the total dose at 4 cm depth and diminished to 0 at 15 cm depth. The amplitude of scatter-dose decreased linearly with the depth increase. The 1D gamma index (2%/2 mm) between the calculated and measured profiles increased from 63% to 98% for 4 cm depth and from 83% to 98% at 13 cm depth. The 2D gamma index (2%/2 mm) at 4 cm depth has improved from 78% to 94%. Conclusion: Using the simple analytical method the discrepancy between the measured and calculated dose has significantly improved.« less

  10. JPSS-1 VIIRS version 2 at-launch relative spectral response characterization and performance

    NASA Astrophysics Data System (ADS)

    Moeller, Chris; Schwarting, Tom; McIntire, Jeff; Moyer, David I.; Zeng, Jinan

    2016-09-01

    The relative spectral response (RSR) characterization of the JPSS-1 VIIRS spectral bands has achieved "at launch" status in the VIIRS Data Analysis Working Group February 2016 Version 2 RSR release. The Version 2 release improves upon the June 2015 Version 1 release by including December 2014 NIST TSIRCUS spectral measurements of VIIRS VisNIR bands in the analysis plus correcting CO2 influence on the band M13 RSR. The T-SIRCUS based characterization is merged with the summer 2014 SpMA based characterization of VisNIR bands (Version 1 release) to yield a "fused" RSR for these bands, combining the strengths of the T-SIRCUS and the SpMA measurement systems. The M13 RSR is updated by applying a model-based correction to mitigate CO2 attenuation of the SpMA source signal that occurred during M13 spectral measurements. The Version 2 release carries forward the Version 1 RSR for those bands that were not updated (M8-M12, M14-M16A/B, I3-I5, DNBMGS). The Version 2 release includes band average (over all detectors and subsamples) RSR plus supporting RSR for each detector and subsample. The at-launch band average RSR have been used to populate Look-Up Tables supporting the sensor data record and environmental data record at-launch science products. Spectral performance metrics show that JPSS-1 VIIRS RSR are compliant on specifications with a few minor exceptions. The Version 2 release, which replaces the Version 1 release, is currently available on the password-protected NASA JPSS-1 eRooms under EAR99 control.

  11. [Impact of quality-indicator-based measures to improve the treatment of acute poisoning in pediatric emergency patients].

    PubMed

    Martínez Sánchez, Lidia; Trenchs Sainz de la Maza, Victoria; Azkunaga Santibáñez, Beatriz; Nogué-Xarau, Santiago; Ferrer Bosch, Nuria; García González, Elsa; Luaces I Cubells, Carles

    2016-02-01

    To analyze the impact of quality-indicator-based measures for improving quality of care for acute poisoning in pediatric emergency departments. Recent assessments of quality indicators were compared with benchmark targets and with results from previous studies. The first study evaluated 6 basic indicators in the pediatric emergency departments of members of to the working group on poisoning of the Spanish Society of Pediatric Emergency Medicine (GTI-SEUP). The second study evaluated 20 indicators in a single emergency department of GTI-SEUP members. Based on the results of those studies, the departments implemented the following corrective measures: creation of a team for gastric lavage follow-up, preparation of a new GTI-SEUP manual on poisoning, implementation of a protocol for poisoning incidents, and creation of specific poisoning-related fields for computerized patient records. The benchmark targets were reached on 4 quality indicators in the first study. Improvements were seen in the availability of protocols, as indicators exceeded the target in all the pediatric emergency departments (vs 29.2% of the departments in an earlier study, P < .001). No other significant improvements were observed. In the second study the benchmarks were reached on 13 indicators. Improvements were seen in compliance with incident reporting to the police (recently, 44.4% vs 19.2% previously, P = .036), case registration in the minimum basic data set (51.0% vs 1.9%, P < .001), and a trend toward increased administration of activated carbon within 2 hours (93.1% vs 83.5%, P = .099). No other significant improvements were seen. The corrective measures led to improvements in some quality indicators. There is still room for improvement in these emergency departamens' care of pediatric poisoning.

  12. KSC-2014-2302

    NASA Image and Video Library

    2014-04-25

    CAPE CANAVERAL, Fla. – Construction workers have installed the framing and some of the inner walls inside Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. Three rows of upper level management consoles remain. The Ground Systems Development and Operations Program is overseeing efforts to create a new firing room based on a multi-user concept. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Dimitri Gerondidakis

  13. KSC-2014-2304

    NASA Image and Video Library

    2014-04-25

    CAPE CANAVERAL, Fla. – Construction workers have installed the framing and some of the inner walls inside Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. Three rows of upper level management consoles remain. The Ground Systems Development and Operations Program is overseeing efforts to create a new firing room based on a multi-user concept. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Dimitri Gerondidakis

  14. KSC-2014-2303

    NASA Image and Video Library

    2014-04-25

    CAPE CANAVERAL, Fla. – Construction workers have installed the framing and some of the inner walls inside Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. Three rows of upper level management consoles remain. The Ground Systems Development and Operations Program is overseeing efforts to create a new firing room based on a multi-user concept. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Dimitri Gerondidakis

  15. 5. INSTRUMENT ROOM INTERIOR, SHOWING BACKS OF CONSOLE LOCKERS. Looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. INSTRUMENT ROOM INTERIOR, SHOWING BACKS OF CONSOLE LOCKERS. Looking northeast to firing control room passageway. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA

  16. 5. METAL SHOP ROOM (AREA 108 ON PLAN CA236R36). Looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. METAL SHOP ROOM (AREA 108 ON PLAN CA-236-R-36). Looking northeast. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  17. 4. NORTH END OF TERMINAL ROOM, SHOP LEVEL SHOWING SPIRAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. NORTH END OF TERMINAL ROOM, SHOP LEVEL SHOWING SPIRAL STAIR TO CABLE RACK. Looking north. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  18. 2. TERMINAL ROOM, SHOP LEVEL INTERIOR, SHOWING MEZZANINE LEVEL CABLE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. TERMINAL ROOM, SHOP LEVEL INTERIOR, SHOWING MEZZANINE LEVEL CABLE RACK AT UPPER RIGHT. Looking north. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  19. FRAMEWORK AND APPLICATION FOR MODELING CONTROL ROOM CREW PERFORMANCE AT NUCLEAR POWER PLANTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronald L Boring; David I Gertman; Tuan Q Tran

    2008-09-01

    This paper summarizes an emerging project regarding the utilization of high-fidelity MIDAS simulations for visualizing and modeling control room crew performance at nuclear power plants. The key envisioned uses for MIDAS-based control room simulations are: (i) the estimation of human error associated with advanced control room equipment and configurations, (ii) the investigative determination of contributory cognitive factors for risk significant scenarios involving control room operating crews, and (iii) the certification of reduced staffing levels in advanced control rooms. It is proposed that MIDAS serves as a key component for the effective modeling of cognition, elements of situation awareness, and riskmore » associated with human performance in next generation control rooms.« less

  20. The Pareto Analysis for Establishing Content Criteria in Surgical Training.

    PubMed

    Kramp, Kelvin H; van Det, Marc J; Veeger, Nic J G M; Pierie, Jean-Pierre E N

    2016-01-01

    Current surgical training is still highly dependent on expensive operating room (OR) experience. Although there have been many attempts to transfer more training to the skills laboratory, little research is focused on which technical behaviors can lead to the highest profit when they are trained outside the OR. The Pareto principle states that in any population that contributes to a common effect, a few account for the bulk of the effect. This principle has been widely used in business management to increase company profits. This study uses the Pareto principle for establishing content criteria for more efficient surgical training. A retrospective study was conducted to assess verbal guidance provided by 9 supervising surgeons to 12 trainees performing 64 laparoscopic cholecystectomies in the OR. The verbal corrections were documented, tallied, and clustered according to the aimed change in novice behavior. The corrections were rank ordered, and a cumulative distribution curve was used to calculate which corrections accounted for 80% of the total number of verbal corrections. In total, 253 different verbal corrections were uttered 1587 times and were categorized into 40 different clusters of aimed changes in novice behaviors. The 35 highest-ranking verbal corrections (14%) and the 11 highest-ranking clusters (28%) accounted for 80% of the total number of given verbal corrections. Following the Pareto principle, we were able to identify the aspects of trainee behavior that account for most corrections given by supervisors during a laparoscopic cholecystectomy on humans. This strategy can be used for the development of new training programs to prepare the trainee in advance for the challenges encountered in the clinical setting in an OR. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  1. Point clouds segmentation as base for as-built BIM creation

    NASA Astrophysics Data System (ADS)

    Macher, H.; Landes, T.; Grussenmeyer, P.

    2015-08-01

    In this paper, a three steps segmentation approach is proposed in order to create 3D models from point clouds acquired by TLS inside buildings. The three scales of segmentation are floors, rooms and planes composing the rooms. First, floor segmentation is performed based on analysis of point distribution along Z axis. Then, for each floor, room segmentation is achieved considering a slice of point cloud at ceiling level. Finally, planes are segmented for each room, and planes corresponding to ceilings and floors are identified. Results of each step are analysed and potential improvements are proposed. Based on segmented point clouds, the creation of as-built BIM is considered in a future work section. Not only the classification of planes into several categories is proposed, but the potential use of point clouds acquired outside buildings is also considered.

  2. Applying a Wearable Voice-Activated Computer to Instructional Applications in Clean Room Environments

    NASA Technical Reports Server (NTRS)

    Graves, Corey A.; Lupisella, Mark L.

    2004-01-01

    The use of wearable computing technology in restrictive environments related to space applications offers promise in a number of domains. The clean room environment is one such domain in which hands-free, heads-up, wearable computing is particularly attractive for education and training because of the nature of clean room work We have developed and tested a Wearable Voice-Activated Computing (WEVAC) system based on clean room applications. Results of this initial proof-of-concept work indicate that there is a strong potential for WEVAC to enhance clean room activities.

  3. Retinal image mosaicing using the radial distortion correction model

    NASA Astrophysics Data System (ADS)

    Lee, Sangyeol; Abràmoff, Michael D.; Reinhardt, Joseph M.

    2008-03-01

    Fundus camera imaging can be used to examine the retina to detect disorders. Similar to looking through a small keyhole into a large room, imaging the fundus with an ophthalmologic camera allows only a limited view at a time. Thus, the generation of a retinal montage using multiple images has the potential to increase diagnostic accuracy by providing larger field of view. A method of mosaicing multiple retinal images using the radial distortion correction (RADIC) model is proposed in this paper. Our method determines the inter-image connectivity by detecting feature correspondences. The connectivity information is converted to a tree structure that describes the spatial relationships between the reference and target images for pairwise registration. The montage is generated by cascading pairwise registration scheme starting from the anchor image downward through the connectivity tree hierarchy. The RADIC model corrects the radial distortion that is due to the spherical-to-planar projection during retinal imaging. Therefore, after radial distortion correction, individual images can be properly mapped onto a montage space by a linear geometric transformation, e.g. affine transform. Compared to the most existing montaging methods, our method is unique in that only a single registration per image is required because of the distortion correction property of RADIC model. As a final step, distance-weighted intensity blending is employed to correct the inter-image differences in illumination encountered when forming the montage. Visual inspection of the experimental results using three mosaicing cases shows our method can produce satisfactory montages.

  4. Effect of automated ultraviolet C-emitting device on decontamination of hospital rooms with and without real-time observation of terminal room disinfection.

    PubMed

    Penno, Katie; Jandarov, Roman A; Sopirala, Madhuri M

    2017-11-01

    We studied the effectiveness of an ultraviolet C (UV-C) emitter in clinical settings and compared it with observed terminal disinfection. We cultured 22 hospital discharge rooms at a tertiary care academic medical center. Phase 1 (unobserved terminal disinfection) included cultures of 11 high-touch environmental surfaces (HTSs) after terminal room disinfection (AD) and after the use of a UV-C-emitting device (AUV). Phase 2 (observed terminal disinfection) included cultures before terminal room disinfection (BD), AD, and AUV. Zero-inflated Poisson regression compared mean colony forming units (CFU) between the groups. Two-sample proportion tests identified significance of the observed differences in proportions of thoroughly cleaned HTSs (CFU < 5). Significant P value was determined using the Bonferroni corrected threshold of α = .05/12 = .004. We obtained 594 samples. Risk of overall contamination was 0.48 times lower in the AUV group than in the AD group (P < .001), with 1.04 log 10 reduction. During phase 1, overall proportion of HTSs with <5 CFUs increased in AUV versus AD by 0.12 (P = .001). During phase 2, it increased in AD versus BD by 0.45 (P < .001), with no significant difference between AD and AUV (P = .02). Use of UV-C with standard cleaning significantly reduced microbial burden and improved the thoroughness of terminal disinfection. We found no further benefit to UV-C use if standard terminal disinfection was observed. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. PDA-phone-based instant transmission of radiological images over a CDMA network by combining the PACS screen with a Bluetooth-interfaced local wireless link.

    PubMed

    Kim, Dong Keun; Yoo, Sun K; Park, Jeong Jin; Kim, Sun Ho

    2007-06-01

    Remote teleconsultation by specialists is important for timely, correct, and specialized emergency surgical and medical decision making. In this paper, we designed a new personal digital assistant (PDA)-phone-based emergency teleradiology system by combining cellular communication with Bluetooth-interfaced local wireless links. The mobility and portability resulting from the use of PDAs and wireless communication can provide a more effective means of emergency teleconsultation without requiring the user to be limited to a fixed location. Moreover, it enables synchronized radiological image sharing between the attending physician in the emergency room and the remote specialist on picture archiving and communication system terminals without distorted image acquisition. To enable rapid and fine-quality radiological image transmission over a cellular network in a secure manner, progressive compression and security mechanisms have been incorporated. The proposed system is tested over a code division Multiple Access 1x-Evolution Data-Only network to evaluate the performance and to demonstrate the feasibility of this system in a real-world setting.

  6. Sensitivity Limits of Rydberg Atom-Based Radio Frequency Electric Field Sensing

    NASA Astrophysics Data System (ADS)

    Jahangiri, Akbar J.; Kumar, Santosh; Kuebler, Harald; Fan, Haoquan; Shaffer, James P.

    2017-04-01

    We present progress on Rydberg atom-based RF electric field sensing using Rydberg state electromagnetically induced transparency (EIT) in room temperature atomic vapor cells. In recent experiments on homodyne detection with a Mach-Zehnder interferometer and frequency modulation spectroscopy with active control of residual amplitude modulation we determined that photon shot noise on the probe laser detector limits the sensitivity. Another factor that limits the accuracy is residual Doppler broadening due to the wave-vector mismatch between the coupling and the probe lasers. The sensor as limited by project noise can be orders of magnitude better. A multi-photon scheme is presented that can eliminate the residual Doppler effect by matching the wave-vectors of three lasers and reduce the photon shot noise limit by correctly choosing the Rabi frequencies of the first two steps of the EIT scheme. Using density matrix calculations, we predict that the three-photon approach can improve the detection sensitivity to below 200 nV cm-1 Hz- 1 / 2 and expand the Autler-Townes regime which improves the accuracy. This work is supported by DARPA and the NRO.

  7. Room Temperature ppb Level Chlorine Gas Sensor Based on Copper (II) 1, 4, 8, 11, 15, 18, 22, 25-octabutoxy-29 H, 31 H-phthalocyanine Films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bedi, R. K.; Saini, Rajan; Mahajan, Aman

    2010-12-01

    Spin coating technique has been used to fabricate room temperature chlorine gas sensor based on copper (II) 1, 4, 8, 11, 15, 18, 22, 25-octabutoxy-29 H, 31 H-phthalocyanine (CuPc(OBu){sub 8}) films. Gas sensor shows a response of 185% to few parts per billion level of Cl{sub 2} gas with response time of 9.5 minutes at room temperature. The interactions between sensor and analytes followed first order kinetics with rate constant 0.01{<=}k{<=}0.02. The chemiresistive sensor showed very good stability at room temperature over a long period of time.

  8. 123. UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751). PUMP ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    123. UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751). PUMP ON LEFT; HYDRAULIC CONTROL PANEL FOR UMBILICAL MAST AND TRENCH DOORS IN CENTER OF ROOM, FACING WEST. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  9. FACILITY 89. INTERIOR OF ENTRY AND STAIR, WITH DINING ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 89. INTERIOR OF ENTRY AND STAIR, WITH DINING ROOM TO LEFT, AS SEEN FROM LIVING ROOM. VIEW FACING SOUTHEAST. - U.S. Naval Base, Pearl Harbor, Naval Housing Area Makalapa, Junior Officers' Quarters Type K, Makin Place, & Halawa, Makalapa, & Midway Drives, Pearl City, Honolulu County, HI

  10. A Web-Based Operating Room Management Educational Tool.

    PubMed

    Tsai, Mitchell H; Haddad, Daniel J; Friend, Alexander F; Bender, S Patrick; Davidson, Melissa L

    2016-08-01

    In 2010, our department instituted a nonclinical, administrative rotation in operating room management for anesthesiology residents. Subsequently, we mandated the rotation for all senior anesthesiology residents in 2013. In 2014, under the auspices of the American Society of Anesthesiologists, we developed a web-based module covering the basics of finance, accounting, and operating room management. A multiple-choice test was given to residents at the beginning and end of the rotation, and we compared the mean scores between residents who took the traditional course and residents who took the web-based module. We found no significant difference between the groups of residents, suggesting that the web-based module is as effective as traditional didactics.

  11. Caracterisation, modelisation et validation du transfert radiatif d'atmospheres non standard; impact sur les corrections atmospheriques d'images de teledetection

    NASA Astrophysics Data System (ADS)

    Zidane, Shems

    This study is based on data acquired with an airborne multi-altitude sensor on July 2004 during a nonstandard atmospheric event in the region of Saint-Jean-sur-Richelieu, Quebec. By non-standard atmospheric event we mean an aerosol atmosphere that does not obey the typical monotonic, scale height variation employed in virtually all atmospheric correction codes. The surfaces imaged during this field campaign included a diverse variety of targets : agricultural land, water bodies, urban areas and forests. The multi-altitude approach employed in this campaign allowed us to better understand the altitude dependent influence of the atmosphere over the array of ground targets and thus to better characterize the perturbation induced by a non-standard (smoke) plume. The transformation of the apparent radiance at 3 different altitudes into apparent reflectance and the insertion of the plume optics into an atmospheric correction model permitted an atmospheric correction of the apparent reflectance at the two higher altitudes. The results showed consistency with the apparent validation reflectances derived from the lowest altitude radiances. This approach effectively confirmed the accuracy of our non-standard atmospheric correction approach. This test was particularly relevant at the highest altitude of 3.17 km : the apparent reflectances at this altitude were above most of the plume and therefore represented a good test of our ability to adequately correct for the influence of the perturbation. Standard atmospheric disturbances are obviously taken into account in most atmospheric correction models, but these are based on monotonically decreasing aerosol variations with increasing altitude. When the atmospheric radiation is affected by a plume or a local, non-standard pollution event, one must adapt the existing models to the radiative transfer constraints of the local perturbation and to the reality of the measurable parameters available for ingestion into the model. The main inputs of this study were those normally used in an atmospheric correction : apparent at-sensor radiance and the aerosol optical depth (AOD) acquired using ground-based sunphotometry. The procedure we employed made use of a standard atmospheric correction code (CAM5S, for Canadian Modified 5S, which comes from the 5S radiative transfer model in the visible and near infrared) : however, we also used other parameters and data to adapt and correctly model the special atmospheric situation which affected the multi-altitude images acquired during the St. Jean field campaign. We then developed a modeling protocol for these atmospheric perturbations where auxiliary data was employed to complement our main data-set. This allowed for the development of a robust and simple methodology adapted to this atmospheric situation. The auxiliary data, i.e. meteorological data, LIDAR profiles, various satellite images and sun photometer retrievals of the scattering phase function, were sufficient to accurately model the observed plume in terms of a unusual, vertical distribution. This distribution was transformed into an aerosol optical depth profile that replaced the standard aerosol optical depth profile employed in the CAM5S atmospheric correction model. Based on this model, a comparison between the apparent ground reflectances obtained after atmospheric corrections and validation values of R*(0) obtained from the lowest altitude data showed that the error between the two was less than 0.01 rms. This correction was shown to be a significantly better estimation of the surface reflectance than that obtained using the atmospheric correction model. Significant differences were nevertheless observed in the non-standard solution : these were mainly caused by the difficulties brought about by the acquisition conditions, significant disparities attributable to inconsistencies in the co-sampling / co-registration of different targets from three different altitudes, and possibly modeling errors and / or calibration. There is accordingly room for improvement in our approach to dealing with such conditions. The modeling and forecasting of such a disturbance is explicitly described in this document: our goal in so doing is to permit the establishment of a better protocol for the acquisition of more suitable supporting data. The originality of this study stems from a new approach for incorporating a plume structure into an operational atmospheric correction model and then demonstrating that the approach was a significant improvement over an approach that ignored the perturbations in the vertical profile while employing the correct overall AOD. The profile model we employed was simple and robust but captured sufficient plume detail to achieve significant improvements in atmospheric correction accuracy. The overall process of addressing all the problems encountered in the analysis of our aerosol perturbation helped us to build an appropriate methodology for characterizing such events based on data availability, distributed freely and accessible to the scientific community. This makes our study adaptable and exportable to other types of non-standard atmospheric events. Keywords : non-standard atmospheric perturbation, multi-altitude apparent radiances, smoke plume, Gaussian plume modelization, radiance fit, AOD, CASI

  12. The cost of caring for end-stage kidney disease patients: an analysis based on hospital financial transaction records.

    PubMed

    Bruns, F J; Seddon, P; Saul, M; Zeidel, M L

    1998-05-01

    The costs of care for end-stage renal disease patients continue to rise because of increased numbers of patients. Efforts to contain these costs have focused on the development of capitated payment schemes, in which all costs for the care of these patients are covered in a single payment. To determine the effect of a capitated reimbursement scheme on care of dialysis patients (both hemodialysis [HD] and peritoneal dialysis [PD]), complete financial records (all reimbursements for inpatient and outpatient care, as well as physician collections) of dialysis patients at a single medical center over 1 year were analyzed. For the period from July 1994 to July 1995, annualized cost per dialysis patient-year averaged $63,340, or 9.8% higher than the corrected estimate from the U.S. Renal Data Service (USRDS; $57,660). The "most expensive" 25% of patients engendered 44 to 48% of the total costs, and inpatient costs accounted for 37 to 40% of total costs. Nearly half of the inpatient costs resulted from only two categories (room charges and inpatient dialysis), whereas other categories each made up a small fraction of the inpatient costs. PD patients were far less expensive to care for than HD patients, due to reduced hospital days and lower cost of outpatient dialysis. Care for a university-based dialysis population was only slightly more expensive than estimates predicted from the USRDS. These results validate the USRDS spending data and suggest that they can be used effectively for setting capitated rates. Efforts to control costs without sacrificing quality of care must center on reducing inpatient costs, particularly room charges and the cost of inpatient dialysis.

  13. Examination of DNA methylation status of the ELOVL2 marker may be useful for human age prediction in forensic science.

    PubMed

    Zbieć-Piekarska, Renata; Spólnicka, Magdalena; Kupiec, Tomasz; Makowska, Żanetta; Spas, Anna; Parys-Proszek, Agnieszka; Kucharczyk, Krzysztof; Płoski, Rafał; Branicki, Wojciech

    2015-01-01

    Age estimation in forensic investigations may complement the prediction of externally visible characteristics and the inference of biogeographical ancestry, thus allowing a better description of an unknown individual. Multiple CpG sites that show linear correlation between age and degree of DNA methylation have been identified in the human genome, providing a selection of candidates for age prediction. In this study, we optimized an assay based on bisulfite conversion and pyrosequencing of 7 CpG sites located in the ELOVL2 gene. Examination of 303 blood samples collected from individuals aged 2-75 years allowed selection of the most informative site, explaining 83% of variation in age. The final linear regression model included two CpG sites in ELOVL2 and enabled age prediction with R(2)=0.859, prediction error=6.85 and mean absolute deviation MAD=5.03. Examination of a testing set of 124 blood samples (MAD=5.75) showed that 68.5% of samples were correctly predicted, assuming that chronological and predicted ages matched ± 7 years. It was found that the ELOVL2 methylation status in bloodstains had not changed significantly after 4 weeks of storage in room temperature conditions. Analysis of 45 bloodstains deposited on tissue paper after 5, 10 and 15 years of storage in room conditions indicated that although a gradual decrease of positive PCR results was observed, the general age prediction success rate remained similar and equaled 60-78%. The obtained results show that the ELOVL2 locus provides a very good source of information about human chronological age based on analysis of blood, including bloodstains, and it may constitute a powerful and reliable predictor in future forensic age estimation models. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Integrating medical devices in the operating room using service-oriented architectures.

    PubMed

    Ibach, Bastian; Benzko, Julia; Schlichting, Stefan; Zimolong, Andreas; Radermacher, Klaus

    2012-08-01

    Abstract With the increasing documentation requirements and communication capabilities of medical devices in the operating room, the integration and modular networking of these devices have become more and more important. Commercial integrated operating room systems are mainly proprietary developments using usually proprietary communication standards and interfaces, which reduce the possibility of integrating devices from different vendors. To overcome these limitations, there is a need for an open standardized architecture that is based on standard protocols and interfaces enabling the integration of devices from different vendors based on heterogeneous software and hardware components. Starting with an analysis of the requirements for device integration in the operating room and the techniques used for integrating devices in other industrial domains, a new concept for an integration architecture for the operating room based on the paradigm of a service-oriented architecture is developed. Standardized communication protocols and interface descriptions are used. As risk management is an important factor in the field of medical engineering, a risk analysis of the developed concept has been carried out and the first prototypes have been implemented.

  15. Effect of tubing condensate on non-invasive positive pressure ventilators tested under simulated clinical conditions.

    PubMed

    Hart, Diana Elizabeth; Forman, Mark; Veale, Andrew G

    2011-09-01

    Water condensate in the humidifier tubing can affect bi-level ventilation by narrowing tube diameter and increasing airflow resistance. We investigated room temperature and tubing type as ways to reduce condensate and its effect on bi-level triggering and pressure delivery. In this bench study, the aim was to test the hypothesis that a relationship exists between room temperature and tubing condensate. Using a patient simulator, a Res-med bi-level device was set to 18/8 cm H(2)O and run for 6 h at room temperatures of 16°C, 18°C and 20°C. The built-in humidifier was set to a low, medium or high setting while using unheated or insulated tubing or replaced with a humidifier using heated tubing. Humidifier output, condensate, mask pressure and triggering delay of the bi-level were measured at 1 and 6 h using an infrared hygrometer, metric weights, Honeywell pressure transducer and TSI pneumotach. When humidity output exceeded 17.5 mg H(2)O/L, inspiratory pressure fell by 2-15 cm H(2)O and triggering was delayed by 0.2-0.9 s. Heating the tubing avoided any such ventilatory effect whereas warmer room temperatures or insulating the tubing were of marginal benefit. Users of bi-level ventilators need to be aware of this problem and its solution. Bi-level humidifier tubing may need to be heated to ensure correct humidification, pressure delivery and triggering.

  16. Job satisfaction or production? How staff and leadership understand operating room efficiency: a qualitative study.

    PubMed

    Arakelian, E; Gunningberg, L; Larsson, J

    2008-11-01

    How to increase efficiency in operating departments has been widely studied. However, there is no overall definition of efficiency. Supervisors urging staff to work efficiently may meet strong reactions due to staff believing that demands for efficiency means just stress at work. Differences in how efficiency is understood may constitute an obstacle to supervisors' efforts to promote it. This study aimed to explore how staff and leadership understand operating room efficiency. Twenty-one members of staff and supervisors in an operating department in a Swedish county hospital were interviewed. The analysis was performed with a phenomenographic approach that aims to discover the variations in how a phenomenon is understood by a group of people. Six categories were found in the understanding of operation room efficiency: (A) having the right qualifications; (B) enjoying work; (C) planning and having good control and overview; (D) each professional performing the correct tasks; (E) completing a work assignment; and (F) producing as much as possible per time unit. The most significant finding was that most of the nurses and assistant nurses understood efficiency as individual knowledge and experience emphasizing the importance of the work process, whereas the supervisors and physicians understood efficiency in terms of production per time unit or completing an assignment. The concept 'operating room efficiency' is understood in different ways by leadership and staff members. Supervisors who are aware of this variation will have better prerequisites for defining the concept and for creating a common platform towards becoming efficient.

  17. An application of corelap algoritm to improve the utilization space of the classroom

    NASA Astrophysics Data System (ADS)

    Sembiring, A. C.; Budiman, I.; Mardhatillah, A.; Tarigan, U. P.; Jawira, A.

    2018-04-01

    The high demand of the room due to the increasing number of students requires the addition of the room The limited number of rooms, the price of land and the cost of building expensive infrastructure requires effective and efficient use of the space. The facility layout redesign is done using the Computerized Relationship Planning (CORELAP) algorithm based on total closeness rating (TCR). By calculating the square distance between the departments based on the coordinates of the central point of the department. The distance obtained is multiplied by the material current from the From-to chart matrix. The analysis is done by comparing the total distance between the initial layout and the proposed layout and then viewing the activities performed in each room. The results of CORELAP algorithm processing gives an increase of room usage efficiency equal to 14, 98% from previous activity.

  18. Clean room survey and assessment, volume 5, appendix H

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The scope of this task is to perform a comparative analysis of the various Environmental Control Life Support System (ECLSS) options for different growth scenarios. The Space Station Freedom ECLSS design and existing ground-based clean room facilities are used as a baseline for comparison. Specifically addressed here are the ground based clean room facilities at the Marshall Space Flight Center (MSFC). Given here is an evaluation of the facilities, equipment, technologies, and procedures used to maintain specified environments in typical aerospace industrial areas. Twenty-five specific clean rooms are evaluated. The objectives were to collect, compare, and catalog data for each specified facility in the areas of engineering and design, construction materials, work stations, contamination control, particulate elimination, entry systems, and instrumentation, and to make recommendations concerning enhancements required to assure an efficient and orderly evolution of MSFC clean room environmental control facilities.

  19. Island custom blocking technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carabetta, R.J.

    The technique of Island blocking is being used more frequently since the advent of our new head and neck blocking techniques and the implementation of a newly devised lung protocol. The system presented affords the mould room personnel a quick and accurate means of island block fabrication without the constant remeasuring or subtle shifting to approximate correct placement. The cookie cutter is easily implemented into any department's existing block cutting techniques. The device is easily and inexpensively made either in a machine shop or acquired by contacting the author.

  20. Ferroelasticity in the LnNbO/sub 4/-type rare earth niobates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brixner, L.H.; Whitney, J.F.; Zumsteg, F.C.

    1977-01-01

    The previously reported phase transitions for the isostructural rare earth niobates between 500/sup 0/C and 850/sup 0/C correspond to a point group transformation 4/mF2/m, which is purely ferroelastic. The correct room temperature point group for all LnNbO/sub 4/ compounds is 2/m. Crystal growth and domain wall behavior is discussed for LaNbO/sub 4/. The high temperature phase transition is described for YbNbO/sub 4/.

  1. Tsunakawa-Shaw method - an absolute paleointensity technique using alternating field demagnetization

    NASA Astrophysics Data System (ADS)

    Yamamoto, Y.; Mochizuki, N.; Shibuya, H.; Tsunakawa, H.

    2015-12-01

    Among geologic materials volcanic rocks have been typically used to deduce an absolute paleointensity. In the last decade, however, there seems a becoming consensus that volcanic rocks are not so ideal materials due to such as magnetic grains other than non-interacting single domain particles. One approach to obtain a good paleointensity estimate from the rocks is to reduce and correct the non-ideality, suppress alterations in laboratory and screen out suspicious results. We have been working on a development and an application of the Tsunakawa-Shaw method, which has been previously called the LTD-DHT Shaw method. This method is an AF(alternating field)-based technique and thus a paleointensity is estimated using coercivity spectra. To reduce the non-ideality, all remanences undergo low-temperature demagnetization (LTD) before any AF demagnetizations to remove multi-domain like component. To correct the non-ideality, anhysteretic remanent magnetizations (ARMs) are imparted with their directions parallel to natural remanent magnetizations and laboratory-imparted thermoremanent magnetizations (TRMs) and measured before and after laboratory heating. These ARMs are used to correct remanence anisotropies, possible interaction effects originated from the non-ideal grains and TRM changes caused by laboratory alterations. TRMs are imparted by heating specimens above their Curie temperatures and then cooling to room temperature at once to simulate nature conditions. These cycles are done in vacuum to suppress alterations in laboratory. Obtained results are judged by selection criteria, including a check for validity of the ARM corrections.It has been demonstrated that successful paleointensities are obtained from historical lavas in Japan and Hawaii, and from baked clay samples from a reconstructed ancient kiln, with the flow-mean precision of 5-10%. In case of old volcanic rocks, however, the method does not necessarily seem to be perfect. We will summarize these points in this presentation.

  2. Fast and automatic depth control of iterative bone ablation based on optical coherence tomography data

    NASA Astrophysics Data System (ADS)

    Fuchs, Alexander; Pengel, Steffen; Bergmeier, Jan; Kahrs, Lüder A.; Ortmaier, Tobias

    2015-07-01

    Laser surgery is an established clinical procedure in dental applications, soft tissue ablation, and ophthalmology. The presented experimental set-up for closed-loop control of laser bone ablation addresses a feedback system and enables safe ablation towards anatomical structures that usually would have high risk of damage. This study is based on combined working volumes of optical coherence tomography (OCT) and Er:YAG cutting laser. High level of automation in fast image data processing and tissue treatment enables reproducible results and shortens the time in the operating room. For registration of the two coordinate systems a cross-like incision is ablated with the Er:YAG laser and segmented with OCT in three distances. The resulting Er:YAG coordinate system is reconstructed. A parameter list defines multiple sets of laser parameters including discrete and specific ablation rates as ablation model. The control algorithm uses this model to plan corrective laser paths for each set of laser parameters and dynamically adapts the distance of the laser focus. With this iterative control cycle consisting of image processing, path planning, ablation, and moistening of tissue the target geometry and desired depth are approximated until no further corrective laser paths can be set. The achieved depth stays within the tolerances of the parameter set with the smallest ablation rate. Specimen trials with fresh porcine bone have been conducted to prove the functionality of the developed concept. Flat bottom surfaces and sharp edges of the outline without visual signs of thermal damage verify the feasibility of automated, OCT controlled laser bone ablation with minimal process time.

  3. Alcohol Production, Prevention Strategies, and Inmate Knowledge About the Risk for Botulism From Pruno Consumption in a Correctional Facility—Arizona, 2013

    PubMed Central

    Adams, Laura E.; Yasmin, Seema; Briggs, Graham; Redden, Kore; Silvas, Suzanne; Anderson, Shoana; Weiss, Joli; Tsang, Clarisse A.; Henke, Evan; Francies, Jessica; Herrick, Kristen; Lira, Rosa; Livar, Eugene; Thompson, Gerald; Sunenshine, Rebecca; Robinson, Byron F.; Bisgard, Kristine M.; Komatsu, Kenneth K.

    2017-01-01

    During July to November 2012, two botulism outbreaks (12 cases total) occurred in one all-male prison; both were associated with illicitly brewed alcohol (pruno) consumption. Inmate surveys were conducted to evaluate and develop prevention and education strategies. Qualitative surveys with open-ended questions were performed among inmates from rooms where outbreaks occurred to learn about pruno consumption. Quantitative surveys assessed knowledge gained after the outbreaks and preferred information sources. For the quantitative surveys, 250 inmates were randomly selected by bed from across the correctional facility and 164 inmates were interviewed. Only 24% of inmates reported any botulism knowledge before the outbreaks and education outreach, whereas 73% reported knowledge after the outbreaks (p < .01). Preferred information sources included handouts/fliers (52%) and the prison television channel (32%). PMID:26285594

  4. Room temperature single-photon detectors for high bit rate quantum key distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Comandar, L. C.; Patel, K. A.; Engineering Department, Cambridge University, 9 J J Thomson Ave., Cambridge CB3 0FA

    We report room temperature operation of telecom wavelength single-photon detectors for high bit rate quantum key distribution (QKD). Room temperature operation is achieved using InGaAs avalanche photodiodes integrated with electronics based on the self-differencing technique that increases avalanche discrimination sensitivity. Despite using room temperature detectors, we demonstrate QKD with record secure bit rates over a range of fiber lengths (e.g., 1.26 Mbit/s over 50 km). Furthermore, our results indicate that operating the detectors at room temperature increases the secure bit rate for short distances.

  5. 132. WEST SIDE OF MECHANICAL AND ELECTRICAL ROOM (210), LSB ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    132. WEST SIDE OF MECHANICAL AND ELECTRICAL ROOM (210), LSB (BLDG. 751), QUALITY CONTROL BOARD ON LEFT. SOUTH SIDE OF TRANSFORMER ROOM (212) ON RIGHT SIDE OF PHOTOGRAPH, THROUGH OPEN DOORS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  6. 51. VIEW OF LORAL ADS 100A COMPUTERS LOCATED CENTRALLY ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. VIEW OF LORAL ADS 100A COMPUTERS LOCATED CENTRALLY ON NORTH WALL OF TELEMETRY ROOM (ROOM 106). SLC-3W CONTROL ROOM IS VISIBLE IN BACKGROUND THROUGH WINDOW IN NORTH WALL. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  7. 14. VIEW OF WEST WALL OF CLEAN ROOM (102) SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. VIEW OF WEST WALL OF CLEAN ROOM (102) SHOWING VIEWING WINDOWS IN WEST FALSE PARTION WALL, WEST WALL OF CLEAN ROOM (102), AND ROLLS OF PLASTIC WRAP FOR COVERING CLEANED FAIRING ASSEMBLY - Vandenberg Air Force Base, Space Launch Complex 3, Vehicle Support Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  8. TOILET ROOM IN THE PROJECTION BOOTH. NOTE THE HEXAGONAL FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    TOILET ROOM IN THE PROJECTION BOOTH. NOTE THE HEXAGONAL FLOOR TILES WITH ACCENTED BORDER AND GLAZED WALL TILES, ALL OF WHICH WERE ORIGINAL/ TYPICAL IN TOILET ROOMS IN THIS FACILITY VIEW FACING NORTHWEST - U.S. Naval Base, Pearl Harbor, Theater, Hornet Avenue between Enterprise & Pokomoke Streets, Pearl City, Honolulu County, HI

  9. Interior. Looking from balance room to the front entrance. Chemicals ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior. Looking from balance room to the front entrance. Chemicals related to Edison's experiments on the extraction of latex for rubber from the goldenrod plant. Room is set up based on reconstruction research done in 1972. - Thomas A. Edison Laboratories, Building No. 2, Main Street & Lakeside Avenue, West Orange, Essex County, NJ

  10. 44. Communication equipment room, cable air dryer on left, motorola ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. Communication equipment room, cable air dryer on left, motorola base station (vhf) in center, telephone repeater group at right, looking west - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  11. Nursing staff's experiences of working in an evidence-based designed ICU patient room-An interview study.

    PubMed

    Sundberg, Fredrika; Olausson, Sepideh; Fridh, Isabell; Lindahl, Berit

    2017-12-01

    It has been known for centuries that environment in healthcare has an impact, but despite this, environment has been overshadowed by technological and medical progress, especially in intensive care. Evidence-based design is a concept concerning integrating knowledge from various research disciplines and its application to healing environments. The aim was to explore the experiences of nursing staff of working in an evidence-based designed ICU patient room. Interviews were carried out with eight critical care nurses and five assistant nurses and then subjected to qualitative content analysis. The experience of working in an evidence-based designed intensive care unit patient room was that the room stimulates alertness and promotes wellbeing in the nursing staff, fostering their caring activities but also that the interior design of the medical and technical equipment challenges nursing actions. The room explored in this study had been rebuilt in order to create and evaluate a healing environment. This study showed that the new environment had a great impact on the caring staffs' wellbeing and their caring behaviour. At a time when turnover in nurses is high and sick leave is increasing, these findings show the importance of interior design ofintensive care units. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Asteroseismic modelling of the solar-like star β Hydri

    NASA Astrophysics Data System (ADS)

    Doğan, G.; Brandão, I. M.; Bedding, T. R.; Christensen-Dalsgaard, J.; Cunha, M. S.; Kjeldsen, H.

    2010-07-01

    We present the results of modelling the subgiant star β Hydri using seismic observational constraints. We have computed several grids of stellar evolutionary tracks using the Aarhus STellar Evolution Code (ASTEC, Christensen-Dalsgaard in Astrophys. Space Sci. 316:13, 2008a), with and without helium diffusion and settling. For those models on each track that are located at the observationally determined position of β Hydri in the Hertzsprung-Russell (HR) diagram, we have calculated the oscillation frequencies using the Aarhus adiabatic pulsation package (ADIPLS, Christensen-Dalsgaard in Astrophys. Space Sci. 316:113, 2008b). Applying the near-surface corrections to the calculated frequencies using the empirical law presented by Kjeldsen et al. (Astrophys. J. 683:L175, 2008), we have compared the corrected model frequencies with the observed frequencies of the star. We show that after correcting the frequencies for the near-surface effects, we have a fairly good fit for both l=0 and l=2 frequencies. We also have good agreement between the observed and calculated l=1 mode frequencies, although there is room for improvement in order to fit all the observed mixed modes simultaneously.

  13. Significant variation between SNP-based HLA imputations in diverse populations: the last mile is the hardest.

    PubMed

    Pappas, D J; Lizee, A; Paunic, V; Beutner, K R; Motyer, A; Vukcevic, D; Leslie, S; Biesiada, J; Meller, J; Taylor, K D; Zheng, X; Zhao, L P; Gourraud, P-A; Hollenbach, J A; Mack, S J; Maiers, M

    2018-05-22

    Four single nucleotide polymorphism (SNP)-based human leukocyte antigen (HLA) imputation methods (e-HLA, HIBAG, HLA*IMP:02 and MAGPrediction) were trained using 1000 Genomes SNP and HLA genotypes and assessed for their ability to accurately impute molecular HLA-A, -B, -C and -DRB1 genotypes in the Human Genome Diversity Project cell panel. Imputation concordance was high (>89%) across all methods for both HLA-A and HLA-C, but HLA-B and HLA-DRB1 proved generally difficult to impute. Overall, <27.8% of subjects were correctly imputed for all HLA loci by any method. Concordance across all loci was not enhanced via the application of confidence thresholds; reliance on confidence scores across methods only led to noticeable improvement (+3.2%) for HLA-DRB1. As the HLA complex is highly relevant to the study of human health and disease, a standardized assessment of SNP-based HLA imputation methods is crucial for advancing genomic research. Considerable room remains for the improvement of HLA-B and especially HLA-DRB1 imputation methods, and no imputation method is as accurate as molecular genotyping. The application of large, ancestrally diverse HLA and SNP reference data sets and multiple imputation methods has the potential to make SNP-based HLA imputation methods a tractable option for determining HLA genotypes.

  14. Radiofrequency-Based Identification Medical Device: An Evaluable Solution for Surgical Sponge Retrieval?

    PubMed

    Lazzaro, Alessandra; Corona, Arianna; Iezzi, Luca; Quaresima, Silvia; Armisi, Luca; Piccolo, Ilaria; Medaglia, Carlo Maria; Sbrenni, Sergio; Sileri, Pierpaolo; Rosato, Nicola; Gaspari, Achille Lucio; Di Lorenzo, Nicola

    2017-06-01

    A retained surgical item in patients (gossypiboma) is a persisting problem, despite consistent improvements and existing guidelines in counting instruments and sponges. Previous experiences with radiofrequency identification technology (RFID) tracking sponges show that it could represent an innovation, in order to reduce the criticism and increase the effectiveness during surgical procedures. We present an automated system that allows reduction of errors and improves safety in the operating room. The system consists of 3 antennas, surgical sponges containing RFID tags, and dedicated software applications, with Wi-Fi real-time communication between devices. The first antenna provides the initial count of gauzes; the second a real-time counting during surgery, including the sponges thrown into the kick-bucket; and the third can be used in the event of uneven sponge count. The software allows management at all stages of the process. In vitro and in vivo tests were performed: the system provided excellent results in detecting sponges in patients' body. Hundred percent retained sponges were detected correctly, even when they were overlapped. No false positive or false negative was recorded. The counting procedure turned out to be more streamlined and efficient and it could save time in a standard procedure. The RFID system for sponge tracking was shown to be experimentally a reliable and feasible method to track sponges with a full detection accuracy in the operating room. The results indicate the system to be safe and effective with acceptable cost-effective parameters.

  15. 8. INTERIOR, CONTROL AND INSTRUMENTATION ROOM. Looking southwest toward entrance ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. INTERIOR, CONTROL AND INSTRUMENTATION ROOM. Looking southwest toward entrance and inner blast door. - Edwards Air Force Base, South Base Sled Track, Firing & Control Blockhouse for 10,000-foot Track, South of Sled Track at midpoint of 20,000-foot track, Lancaster, Los Angeles County, CA

  16. View of equipment building and tower base, looking southeast. Door ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of equipment building and tower base, looking southeast. Door opens to radio room, and hood covers the engine room outlet. Vertical pipe with cap above roof is fuel tank vent. - Western Union Telegraph Company, Jennerstown Relay, Laurel Summit Road off U.S. 30, Laughlintown, Westmoreland County, PA

  17. Quantification of Rifapentine, a Potent Antituberculosis Drug, from Dried Blood Spot Samples Using Liquid Chromatographic-Tandem Mass Spectrometric Analysis

    PubMed Central

    Parsons, Teresa L.; Marzinke, Mark A.; Hoang, Thuy; Bliven-Sizemore, Erin; Weiner, Marc; Mac Kenzie, William R.; Dorman, Susan E.

    2014-01-01

    The quantification of antituberculosis drug concentrations in multinational trials currently requires the collection of modest blood volumes, centrifugation, aliquoting of plasma, freezing, and keeping samples frozen during shipping. We prospectively enrolled healthy individuals into the Tuberculosis Trials Consortium Study 29B, a phase I dose escalation study of rifapentine, a rifamycin under evaluation in tuberculosis treatment trials. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying rifapentine in whole blood on dried blood spots (DBS) to facilitate pharmacokinetic/pharmacodynamic analyses in clinical trials. Paired plasma and whole-blood samples were collected by venipuncture, and whole blood was spotted on Whatman protein saver 903 cards. The methods were optimized for plasma and then validated for DBS. The analytical measuring range for quantification of rifapentine and its metabolite was 50 to 80,000 ng/ml in whole-blood DBS. The analyte was stable on the cards for 11 weeks with a desiccant at room temperature and protected from light. The method concordance for paired plasma and whole-blood DBS samples was determined after correcting for participant hematocrit or population-based estimates of bias from Bland-Altman plots. The application of either correction factor resulted in acceptable correlation between plasma and whole-blood DBS (Passing-Bablok regression corrected for hematocrit; y = 0.98x + 356). Concentrations of rifapentine may be determined from whole-blood DBS collected via venipuncture after normalization in order to account for the dilutional effects of red blood cells. Additional studies are focused on the application of this methodology to capillary blood collected by finger stick. The simplicity of processing, storage, shipping, and low blood volume makes whole-blood DBS attractive for rifapentine pharmacokinetic evaluations, especially in international and pediatric trials. PMID:25182637

  18. Cross correlation calculations and neutron scattering analysis for a portable solid state neutron detection system

    NASA Astrophysics Data System (ADS)

    Saltos, Andrea

    In efforts to perform accurate dosimetry, Oakes et al. [Nucl. Intrum. Mehods. (2013)] introduced a new portable solid state neutron rem meter based on an adaptation of the Bonner sphere and the position sensitive long counter. The system utilizes high thermal efficiency neutron detectors to generate a linear combination of measurement signals that are used to estimate the incident neutron spectra. The inversion problem associated to deduce dose from the counts in individual detector elements is addressed by applying a cross-correlation method which allows estimation of dose with average errors less than 15%. In this work, an evaluation of the performance of this system was extended to take into account new correlation techniques and neutron scattering contribution. To test the effectiveness of correlations, the Distance correlation, Pearson Product-Moment correlation, and their weighted versions were performed between measured spatial detector responses obtained from nine different test spectra, and the spatial response of Library functions generated by MCNPX. Results indicate that there is no advantage of using the Distance Correlation over the Pearson Correlation, and that weighted versions of these correlations do not increase their performance in evaluating dose. Both correlations were proven to work well even at low integrated doses measured for short periods of time. To evaluate the contribution produced by room-return neutrons on the dosimeter response, MCNPX was used to simulate dosimeter responses for five isotropic neutron sources placed inside different sizes of rectangular concrete rooms. Results show that the contribution of scattered neutrons to the response of the dosimeter can be significant, so that for most cases the dose is over predicted with errors as large as 500%. A possible method to correct for the contribution of room-return neutrons is also assessed and can be used as a good initial estimate on how to approach the problem.

  19. Advanced error-prediction LDPC with temperature compensation for highly reliable SSDs

    NASA Astrophysics Data System (ADS)

    Tokutomi, Tsukasa; Tanakamaru, Shuhei; Iwasaki, Tomoko Ogura; Takeuchi, Ken

    2015-09-01

    To improve the reliability of NAND Flash memory based solid-state drives (SSDs), error-prediction LDPC (EP-LDPC) has been proposed for multi-level-cell (MLC) NAND Flash memory (Tanakamaru et al., 2012, 2013), which is effective for long retention times. However, EP-LDPC is not as effective for triple-level cell (TLC) NAND Flash memory, because TLC NAND Flash has higher error rates and is more sensitive to program-disturb error. Therefore, advanced error-prediction LDPC (AEP-LDPC) has been proposed for TLC NAND Flash memory (Tokutomi et al., 2014). AEP-LDPC can correct errors more accurately by precisely describing the error phenomena. In this paper, the effects of AEP-LDPC are investigated in a 2×nm TLC NAND Flash memory with temperature characterization. Compared with LDPC-with-BER-only, the SSD's data-retention time is increased by 3.4× and 9.5× at room-temperature (RT) and 85 °C, respectively. Similarly, the acceptable BER is increased by 1.8× and 2.3×, respectively. Moreover, AEP-LDPC can correct errors with pre-determined tables made at higher temperatures to shorten the measurement time before shipping. Furthermore, it is found that one table can cover behavior over a range of temperatures in AEP-LDPC. As a result, the total table size can be reduced to 777 kBytes, which makes this approach more practical.

  20. Operating Room Fires and Surgical Skin Preparation.

    PubMed

    Jones, Edward L; Overbey, Douglas M; Chapman, Brandon C; Jones, Teresa S; Hilton, Sarah A; Moore, John T; Robinson, Thomas N

    2017-07-01

    Operating room fires are "never events" that remain an under-reported source of devastating complications. One common set-up that promotes fires is the use of surgical skin preparations combined with electrosurgery and oxygen. Limited data exist examining the incidence of fires and surgical skin preparations. A standardized, ex vivo model was created with a 15 × 15 cm section of clipped porcine skin. An electrosurgical "Bovie" pencil was activated for 2 seconds on 30 Watts coagulation mode in 21% oxygen (room air), both immediately and 3 minutes after skin preparation application. Skin preparations with and without alcohol were tested, and were applied with and without pooling. Alcohol-based skin preparations included 70% isopropyl alcohol (IPA) with 2% chlorhexidine gluconate, 74% IPA with 0.7% iodine povacrylex, and plain 70% IPA. No fires occurred with nonalcohol-based preparations (p < 0.001 vs alcohol-based preparations). Alcohol-based preparations caused flash flames at 0 minutes in 22% (13 of 60) and at 3 minutes in 10% (6 of 60) of tests. When examining pooling of alcohol-based preparations, fires occurred in 38% (23 of 60) at 0 minutes and 27% (16 of 60) at 3 minutes. Alcohol-based skin preparations fuel operating room fires in common clinical scenarios. Following manufacturer guidelines and allowing 3 minutes for drying, surgical fires were still created in 1 in 10 cases without pooling and more than one-quarter of cases with pooling. Surgeons can decrease the risk of an operating room fire by using nonalcohol-based skin preparations or avoiding pooling of the preparation solution. Published by Elsevier Inc.

  1. KSC-2014-1969

    NASA Image and Video Library

    2014-04-03

    CAPE CANAVERAL, Fla. – Three rows of upper level management consoles are all that remain in Firing Room 4 in the Launch Control Center at NASA’s Kennedy Space Center in Florida. The main floor consoles, cabling and wires below the floor and ceiling tiles above have been removed. The Ground Systems Development and Operations Program is overseeing efforts to create a new firing room based on a multi-user concept that will support NASA and commercial launch needs. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky

  2. KSC-2014-1970

    NASA Image and Video Library

    2014-04-03

    CAPE CANAVERAL, Fla. – Three rows of upper level management consoles are all that remain in Firing Room 4 in the Launch Control Center at NASA’s Kennedy Space Center in Florida. The main floor consoles, cabling and wires below the floor and ceiling tiles above have been removed. The Ground Systems Development and Operations Program is overseeing efforts to create a new firing room based on a multi-user concept that will support NASA and commercial launch needs. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky

  3. Timeliness and access to healthcare services via telemedicine for adolescents in state correctional facilities.

    PubMed

    Fox, Karen C; Somes, Grant W; Waters, Teresa M

    2007-08-01

    The aim of this study was to examine the effectiveness of a telemedicine program in improving timeliness of and access to healthcare services in adolescent correctional facilities. This study is a pre/post quasi-experimental design comparing time to treatment and healthcare use in the year preceding and the 2 years after the implementation of a telemedicine program in four facilities housing adolescents from 12 to 19. Timeliness of care is measured by time from referral to date of service (for behavioral healthcare only). Access to care is measured by use of outpatient care, emergency department (ED) visits, and inpatient visits. Two of the four state correctional facilities had a significant decrease (24%) in time from referral to treatment after the implementation of the telemedicine intervention. The facilities not showing significant improvements in timeliness experienced difficulty implementing the telemedicine program. The telemedicine program was also associated with significant improvements in access to care. Outpatient visits increased by 40% in the 2 years after implementation of telemedicine. For each 1% increase in telemedicine usage, outpatient visits increased by 1%, whereas emergency room visits decreased by 7%. Telemedicine can have a positive impact on timeliness of and access to care for youth in correctional facilities.

  4. Real-time modeling of heat distributions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamann, Hendrik F.; Li, Hongfei; Yarlanki, Srinivas

    Techniques for real-time modeling temperature distributions based on streaming sensor data are provided. In one aspect, a method for creating a three-dimensional temperature distribution model for a room having a floor and a ceiling is provided. The method includes the following steps. A ceiling temperature distribution in the room is determined. A floor temperature distribution in the room is determined. An interpolation between the ceiling temperature distribution and the floor temperature distribution is used to obtain the three-dimensional temperature distribution model for the room.

  5. Real-time Internet connections: implications for surgical decision making in laparoscopy.

    PubMed

    Broderick, T J; Harnett, B M; Doarn, C R; Rodas, E B; Merrell, R C

    2001-08-01

    To determine whether a low-bandwidth Internet connection can provide adequate image quality to support remote real-time surgical consultation. Telemedicine has been used to support care at a distance through the use of expensive equipment and broadband communication links. In the past, the operating room has been an isolated environment that has been relatively inaccessible for real-time consultation. Recent technological advances have permitted videoconferencing over low-bandwidth, inexpensive Internet connections. If these connections are shown to provide adequate video quality for surgical applications, low-bandwidth telemedicine will open the operating room environment to remote real-time surgical consultation. Surgeons performing a laparoscopic cholecystectomy in Ecuador or the Dominican Republic shared real-time laparoscopic images with a panel of surgeons at the parent university through a dial-up Internet account. The connection permitted video and audio teleconferencing to support real-time consultation as well as the transmission of real-time images and store-and-forward images for observation by the consultant panel. A total of six live consultations were analyzed. In addition, paired local and remote images were "grabbed" from the video feed during these laparoscopic cholecystectomies. Nine of these paired images were then placed into a Web-based tool designed to evaluate the effect of transmission on image quality. The authors showed for the first time the ability to identify critical anatomic structures in laparoscopy over a low-bandwidth connection via the Internet. The consultant panel of surgeons correctly remotely identified biliary and arterial anatomy during six laparoscopic cholecystectomies. Within the Web-based questionnaire, 15 surgeons could not blindly distinguish the quality of local and remote laparoscopic images. Low-bandwidth, Internet-based telemedicine is inexpensive, effective, and almost ubiquitous. Use of these inexpensive, portable technologies will allow sharing of surgical procedures and decisions regardless of location. Internet telemedicine consistently supported real-time intraoperative consultation in laparoscopic surgery. The implications are broad with respect to quality improvement and diffusion of knowledge as well as for basic consultation.

  6. Hypothermia is associated with increased mortality in patients undergoing repair of ruptured abdominal aortic aneurysm.

    PubMed

    Quiroga, Elina; Tran, Nam T; Hatsukami, Thomas; Starnes, Benjamin W

    2010-06-01

    To evaluate the impact of hypothermia on mortality in patients presenting with ruptured abdominal aortic aneurysms (rAAA). Between July 2007 and September 2009, 73 patients with ruptured AAAs presented to our Emergency Department (ED). Thirteen patients did not receive surgical treatment; of the 60 patients (46 men; mean age 76 years, range 63-90) who did, 35 had endovascular aneurysm repair (EVAR) and 25 open repair. Body temperatures, which were recorded upon arrival to the ED and operating room, during the procedure, and just prior to leaving the operating room, were analyzed for any association with mortality or hypotension. The primary outcome measure was the 30-day mortality rate. Six (17%) patients in the EVAR group and 10 (40%) patients in the open group died during the 30-day period. Temperature upon arrival to OR, lowest temperature recorded during the procedure, and temperature at the end of the procedure were higher among survivors (p<0.005), independent of the repair technique implemented. Patients in the EVAR group left the OR with a mean temperature of 35.5 degrees C versus 35.0 degrees C for patients in the open group (p = 0.12). Hypothermia is associated with increased mortality after repair of rAAA. Efforts to correct hypothermia are more frequently successful in patients undergoing EVAR. Increased communication with anesthesia providers, as well as aggressive measures to correct hypothermia, including active intravascular rewarming methods, should be considered to improve mortality in this gravely ill patient population.

  7. West wall, display area (room 101), view 4 of 4: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    West wall, display area (room 101), view 4 of 4: northwest corner, with D.M. logistics office below (room 137), and D.O./D.D.O. offices above. Lower stairs lead to entry shown in view 13 - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  8. Room Use for Group Instruction in Regularly Scheduled Classes.

    ERIC Educational Resources Information Center

    Phay, John E.; McCary, Arthur D.

    A method by which accurate accounting by computer might be made of apace and room use by regularly scheduled classes in institutions of higher learning is furnished. Based on well-defined terms, a master room schedule and a master course schedule are prepared on computer cards. This information is then compared with the reported individual room…

  9. Wayfinding and Glaucoma: A Virtual Reality Experiment.

    PubMed

    Daga, Fábio B; Macagno, Eduardo; Stevenson, Cory; Elhosseiny, Ahmed; Diniz-Filho, Alberto; Boer, Erwin R; Schulze, Jürgen; Medeiros, Felipe A

    2017-07-01

    Wayfinding, the process of determining and following a route between an origin and a destination, is an integral part of everyday tasks. The purpose of this study was to investigate the impact of glaucomatous visual field loss on wayfinding behavior using an immersive virtual reality (VR) environment. This cross-sectional study included 31 glaucomatous patients and 20 healthy subjects without evidence of overall cognitive impairment. Wayfinding experiments were modeled after the Morris water maze navigation task and conducted in an immersive VR environment. Two rooms were built varying only in the complexity of the visual scene in order to promote allocentric-based (room A, with multiple visual cues) versus egocentric-based (room B, with single visual cue) spatial representations of the environment. Wayfinding tasks in each room consisted of revisiting previously visible targets that subsequently became invisible. For room A, glaucoma patients spent on average 35.0 seconds to perform the wayfinding task, whereas healthy subjects spent an average of 24.4 seconds (P = 0.001). For room B, no statistically significant difference was seen on average time to complete the task (26.2 seconds versus 23.4 seconds, respectively; P = 0.514). For room A, each 1-dB worse binocular mean sensitivity was associated with 3.4% (P = 0.001) increase in time to complete the task. Glaucoma patients performed significantly worse on allocentric-based wayfinding tasks conducted in a VR environment, suggesting visual field loss may affect the construction of spatial cognitive maps relevant to successful wayfinding. VR environments may represent a useful approach for assessing functional vision endpoints for clinical trials of emerging therapies in ophthalmology.

  10. The issue of delivery room infections in the Italian law. A brief comparative study with English and French jurisprudence.

    PubMed

    Zaami, Simona; Montanari Vergallo, Gianluca; Napoletano, Simona; Signore, Fabrizio; Marinelli, Enrico

    2018-01-01

    Delivery room infections are frequent, and many of them could be avoided through higher standards of care. The authors examine this issue by comparing it to English and French reality. Unlike England, in Italy and France the relationship established between health facility, physician and patient is outlined in a contract. In England, the judges' decisions converge toward a better and higher protection of the patient-the actor-and facilitate the probative task. In case of infections, including those occurring in the delivery room, three issues are evaluated: the hospital's negligent conduct, damages if any and causal nexus. Therefore, the hospital must demonstrate to have taken the appropriate asepsis measures according to current scientific knowledge concerning not only treatment, but also diagnosis, previous activities, surgery and post-surgery. In order to avoid a negative sentence, both physicians and hospital have to demonstrate their correct behavior and that the infection was caused by an unforeseeable event. The authors examine the most significant rulings by the Courts and the Supreme Court. They show that hospitals can avoid being accused of negligence and recklessness only if they can demonstrate to have implemented all the preventive measures provided for in the guidelines or protocols.

  11. Comparing Explicit Exemplar-Based and Rule-Based Corrective Feedback: Introducing Analogy-Based Corrective Feedback

    ERIC Educational Resources Information Center

    Thomas, Kavita E.

    2018-01-01

    This study introduces an approach to providing corrective feedback to L2 learners termed analogy-based corrective feedback that is motivated by analogical learning theories and syntactic alignment in dialogue. Learners are presented with a structurally similar synonymous version of their output where the erroneous form is corrected, and they must…

  12. Prevention of 3 "never events" in the operating room: fires, gossypiboma, and wrong-site surgery.

    PubMed

    Zahiri, Hamid R; Stromberg, Jeffrey; Skupsky, Hadas; Knepp, Erin K; Folstein, Matthew; Silverman, Ronald; Singh, Devinder

    2011-03-01

    This study sought to identify and provide preventative recommendations for potentially devastating safety violations in the operating room. A Medline database search from 1950 to current using the terms patient safety and operating room was conducted. All topics identified were reviewed. Three patient safety violations with potential for immediate and devastating outcomes were selected for discussion using evidence-based literature. The search identified 2851 articles, 807 of which were directly related to patient safety in the operating room. Topics addressed by these 807 included infectious complications (26%), fires (11%), communication/teamwork (6%), retained foreign objects (3%), safety checklists (1%), and wrong-site surgery (1%). Fires, gossypiboma, and wrong-site surgery were selected for discussion. Although fire, gossypiboma, and wrong-site surgery should be "never events" in the operating room, they continue to persist as 3 common patient safety violations. This study provides the epidemiology, common etiologies, and evidence-based preventative recommendations for each.

  13. Room acoustics analysis using circular arrays: an experimental study based on sound field plane-wave decomposition.

    PubMed

    Torres, Ana M; Lopez, Jose J; Pueo, Basilio; Cobos, Maximo

    2013-04-01

    Plane-wave decomposition (PWD) methods using microphone arrays have been shown to be a very useful tool within the applied acoustics community for their multiple applications in room acoustics analysis and synthesis. While many theoretical aspects of PWD have been previously addressed in the literature, the practical advantages of the PWD method to assess the acoustic behavior of real rooms have been barely explored so far. In this paper, the PWD method is employed to analyze the sound field inside a selected set of real rooms having a well-defined purpose. To this end, a circular microphone array is used to capture and process a number of impulse responses at different spatial positions, providing angle-dependent data for both direct and reflected wavefronts. The detection of reflected plane waves is performed by means of image processing techniques applied over the raw array response data and over the PWD data, showing the usefulness of image-processing-based methods for room acoustics analysis.

  14. A Photoactivated Gas Detector for Toluene Sensing at Room Temperature Based on New Coral-Like ZnO Nanostructure Arrays

    PubMed Central

    Yeh, Li-Ko; Luo, Jie-Chun; Chen, Min-Chun; Wu, Chih-Hung; Chen, Jian-Zhang; Cheng, I-Chun; Hsu, Cheng-Che; Tian, Wei-Cheng

    2016-01-01

    A photoactivated gas detector operated at room temperature was microfabricated using a simple hydrothermal method. We report that the photoactivated gas detector can detect toluene using a UV illumination of 2 μW/cm2. By ultraviolet (UV) illumination, gas detectors sense toluene at room temperature without heating. A significant enhancement of detector sensitivity is achieved because of the high surface-area-to-volume ratio of the morphology of the coral-like ZnO nanorods arrays (NRAs) and the increased number of photo-induced oxygen ions under UV illumination. The corresponding sensitivity (ΔR/R0) of the detector based on coral-like ZnO NRAs is enhanced by approximately 1022% compared to that of thin-film detectors. The proposed detector greatly extends the dynamic range of detection of metal-oxide-based detectors for gas sensing applications. We report the first-ever detection of toluene with a novel coral-like NRAs gas detector at room temperature. A sensing mechanism model is also proposed to explain the sensing responses of gas detectors based on coral-like ZnO NRAs. PMID:27809222

  15. A Photoactivated Gas Detector for Toluene Sensing at Room Temperature Based on New Coral-Like ZnO Nanostructure Arrays.

    PubMed

    Yeh, Li-Ko; Luo, Jie-Chun; Chen, Min-Chun; Wu, Chih-Hung; Chen, Jian-Zhang; Cheng, I-Chun; Hsu, Cheng-Che; Tian, Wei-Cheng

    2016-10-31

    A photoactivated gas detector operated at room temperature was microfabricated using a simple hydrothermal method. We report that the photoactivated gas detector can detect toluene using a UV illumination of 2 μW/cm². By ultraviolet (UV) illumination, gas detectors sense toluene at room temperature without heating. A significant enhancement of detector sensitivity is achieved because of the high surface-area-to-volume ratio of the morphology of the coral-like ZnO nanorods arrays (NRAs) and the increased number of photo-induced oxygen ions under UV illumination. The corresponding sensitivity (ΔR/R₀) of the detector based on coral-like ZnO NRAs is enhanced by approximately 1022% compared to that of thin-film detectors. The proposed detector greatly extends the dynamic range of detection of metal-oxide-based detectors for gas sensing applications. We report the first-ever detection of toluene with a novel coral-like NRAs gas detector at room temperature. A sensing mechanism model is also proposed to explain the sensing responses of gas detectors based on coral-like ZnO NRAs.

  16. Room temperature CO and H2 sensing with carbon nanoparticles.

    PubMed

    Kim, Daegyu; Pikhitsa, Peter V; Yang, Hongjoo; Choi, Mansoo

    2011-12-02

    We report on a shell-shaped carbon nanoparticle (SCNP)-based gas sensor that reversibly detects reducing gas molecules such as CO and H(2) at room temperature both in air and inert atmosphere. Crystalline SCNPs were synthesized by laser-assisted reactions in pure acetylene gas flow, chemically treated to obtain well-dispersed SCNPs and then patterned on a substrate by the ion-induced focusing method. Our chemically functionalized SCNP-based gas sensor works for low concentrations of CO and H(2) at room temperature even without Pd or Pt catalysts commonly used for splitting H(2) molecules into reactive H atoms, while metal oxide gas sensors and bare carbon-nanotube-based gas sensors for sensing CO and H(2) molecules can operate only at elevated temperatures. A pristine SCNP-based gas sensor was also examined to prove the role of functional groups formed on the surface of functionalized SCNPs. A pristine SCNP gas sensor showed no response to reducing gases at room temperature but a significant response at elevated temperature, indicating a different sensing mechanism from a chemically functionalized SCNP sensor.

  17. Efficiency of endoscopy units can be improved with use of discrete event simulation modeling.

    PubMed

    Sauer, Bryan G; Singh, Kanwar P; Wagner, Barry L; Vanden Hoek, Matthew S; Twilley, Katherine; Cohn, Steven M; Shami, Vanessa M; Wang, Andrew Y

    2016-11-01

    Background and study aims: The projected increased demand for health services obligates healthcare organizations to operate efficiently. Discrete event simulation (DES) is a modeling method that allows for optimization of systems through virtual testing of different configurations before implementation. The objective of this study was to identify strategies to improve the daily efficiencies of an endoscopy center with the use of DES. Methods: We built a DES model of a five procedure room endoscopy unit at a tertiary-care university medical center. After validating the baseline model, we tested alternate configurations to run the endoscopy suite and evaluated outcomes associated with each change. The main outcome measures included adequate number of preparation and recovery rooms, blocked inflow, delay times, blocked outflows, and patient cycle time. Results: Based on a sensitivity analysis, the adequate number of preparation rooms is eight and recovery rooms is nine for a five procedure room unit (total 3.4 preparation and recovery rooms per procedure room). Simple changes to procedure scheduling and patient arrival times led to a modest improvement in efficiency. Increasing the preparation/recovery rooms based on the sensitivity analysis led to significant improvements in efficiency. Conclusions: By applying tools such as DES, we can model changes in an environment with complex interactions and find ways to improve the medical care we provide. DES is applicable to any endoscopy unit and would be particularly valuable to those who are trying to improve on the efficiency of care and patient experience.

  18. Efficiency of endoscopy units can be improved with use of discrete event simulation modeling

    PubMed Central

    Sauer, Bryan G.; Singh, Kanwar P.; Wagner, Barry L.; Vanden Hoek, Matthew S.; Twilley, Katherine; Cohn, Steven M.; Shami, Vanessa M.; Wang, Andrew Y.

    2016-01-01

    Background and study aims: The projected increased demand for health services obligates healthcare organizations to operate efficiently. Discrete event simulation (DES) is a modeling method that allows for optimization of systems through virtual testing of different configurations before implementation. The objective of this study was to identify strategies to improve the daily efficiencies of an endoscopy center with the use of DES. Methods: We built a DES model of a five procedure room endoscopy unit at a tertiary-care university medical center. After validating the baseline model, we tested alternate configurations to run the endoscopy suite and evaluated outcomes associated with each change. The main outcome measures included adequate number of preparation and recovery rooms, blocked inflow, delay times, blocked outflows, and patient cycle time. Results: Based on a sensitivity analysis, the adequate number of preparation rooms is eight and recovery rooms is nine for a five procedure room unit (total 3.4 preparation and recovery rooms per procedure room). Simple changes to procedure scheduling and patient arrival times led to a modest improvement in efficiency. Increasing the preparation/recovery rooms based on the sensitivity analysis led to significant improvements in efficiency. Conclusions: By applying tools such as DES, we can model changes in an environment with complex interactions and find ways to improve the medical care we provide. DES is applicable to any endoscopy unit and would be particularly valuable to those who are trying to improve on the efficiency of care and patient experience. PMID:27853739

  19. 94. VIEW OF LSB (BLDG. 770) EAST EXIT FROM SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    94. VIEW OF LSB (BLDG. 770) EAST EXIT FROM SOUTH SIDE OF LANDLINE INSTRUMENTATION ROOM (106). SOUTHWEST CORNER OF UNINTERRUPTABLE POWER SUPPLY (UPS) VISIBLE ON EAST WALL OF LANDLINE INSTRUMENTATION ROOM (106). ROOM 101 ENTRANCE OFF HALLWAY TO LEFT OF EXIT. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  20. Microcontroller based automatic temperature control for oyster mushroom plants

    NASA Astrophysics Data System (ADS)

    Sihombing, P.; Astuti, T. P.; Herriyance; Sitompul, D.

    2018-03-01

    In the cultivation of Oyster Mushrooms need special treatment because oyster mushrooms are susceptible to disease. Mushroom growth will be inhibited if the temperature and humidity are not well controlled because temperature and inertia can affect mold growth. Oyster mushroom growth usually will be optimal at temperatures around 22-28°C and humidity around 70-90%. This problem is often encountered in the cultivation of oyster mushrooms. Therefore it is very important to control the temperature and humidity of the room of oyster mushroom cultivation. In this paper, we developed an automatic temperature monitoring tool in the cultivation of oyster mushroom-based Arduino Uno microcontroller. We have designed a tool that will control the temperature and humidity automatically by Android Smartphone. If the temperature increased more than 28°C in the room of mushroom plants, then this tool will turn on the pump automatically to run water in order to lower the room temperature. And if the room temperature of mushroom plants below of 22°C, then the light will be turned on in order to heat the room. Thus the temperature in the room oyster mushrooms will remain stable so that the growth of oyster mushrooms can grow with good quality.

  1. INTERIOR OF LOCKER ROOM. view TO SOUTHWEST. Plattsburgh Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR OF LOCKER ROOM. view TO SOUTHWEST. - Plattsburgh Air Force Base, Air Force Communications Systems (AFCS) Maintenance Facility, Off Alabama Avenue, adjacent to Flightline Apron, Plattsburgh, Clinton County, NY

  2. INTERIOR OF BRIEFING ROOM A. view TO NORTHWEST Plattsburgh ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR OF BRIEFING ROOM A. view TO NORTHWEST - Plattsburgh Air Force Base, Target Intelligence Training Building-Combat Center, Off Connecticut Road, east of Idaho Avenue, Plattsburgh, Clinton County, NY

  3. INTERIOR OF TARGET INTELLIGENCE ROOM. view TO WEST. Plattsburgh ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR OF TARGET INTELLIGENCE ROOM. view TO WEST. - Plattsburgh Air Force Base, Target Intelligence Training Building-Combat Center, Off Connecticut Road, east of Idaho Avenue, Plattsburgh, Clinton County, NY

  4. INTERIOR OF TYPICAL MUNITIONS INSPECTION ROOM. VIEW TO SOUTH WEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR OF TYPICAL MUNITIONS INSPECTION ROOM. VIEW TO SOUTH- WEST. - Plattsburgh Air Force Base, Conventional Munitions Shop, Off Perimeter Road in Weapons Storage Area, Plattsburgh, Clinton County, NY

  5. Ultrahigh-sensitive sensing platform based on p-type dumbbell-like Co3O4 network

    NASA Astrophysics Data System (ADS)

    Zhou, Tingting; Zhang, Tong; Zhang, Rui; Lou, Zheng; Deng, Jianan; Wang, Lili

    2017-12-01

    Development of high performance room temperature sensors remains a grand challenge for high demand of practical application. Metal oxide semiconductors (MOSs) have many advantages over others due to their easy functionalization, high surface area, and low cost. However, they typically need a high work temperature during sensing process. Here, p-type sensing layer is reported, consisting of pore-rich dumbbell-like Co3O4 particles (DP-Co3O4) with intrinsic high catalytic activity. The gas sensor (GS) based DP-Co3O4 catalyst exhibits ultrahigh NH3 sensing activity along with excellent stability over other structure based NH3 GSs in room temperature work environment. In addition, the unique structure of DP-Co3O4 with pore-rich and high catalytic activity endows fast gas diffusion rate and high sensitivity at room temperature. Taken together, the findings in this work highlight the merit of integrating highly active materials in p-type materials, offering a framework to develop high-sensitivity room temperature sensing platforms.

  6. Using an integrative mock-up simulation approach for evidence-based evaluation of operating room design prototypes.

    PubMed

    Bayramzadeh, Sara; Joseph, Anjali; Allison, David; Shultz, Jonas; Abernathy, James

    2018-07-01

    This paper describes the process and tools developed as part of a multidisciplinary collaborative simulation-based approach for iterative design and evaluation of operating room (OR) prototypes. Full-scale physical mock-ups of healthcare spaces offer an opportunity to actively communicate with and to engage multidisciplinary stakeholders in the design process. While mock-ups are increasingly being used in healthcare facility design projects, they are rarely evaluated in a manner to support active user feedback and engagement. Researchers and architecture students worked closely with clinicians and architects to develop OR design prototypes and engaged clinical end-users in simulated scenarios. An evaluation toolkit was developed to compare design prototypes. The mock-up evaluation helped the team make key decisions about room size, location of OR table, intra-room zoning, and doors location. Structured simulation based mock-up evaluations conducted in the design process can help stakeholders visualize their future workspace and provide active feedback. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Resolution of alliance ruptures: The special case of animal-assisted psychotherapy.

    PubMed

    Zilcha-Mano, Sigal

    2017-01-01

    Many therapists regard alliance ruptures as one of the greatest challenges therapists face in the therapy room. Alliance ruptures has been previously defined as breakdowns in the process of negotiation of treatment tasks and goals and a deterioration in the affective bond between patient and therapist. Alliance ruptures have been found to predict premature termination of treatment and poor treatment outcomes. But ruptures can also present important opportunities for gaining insight and awareness and for facilitating therapeutic change. A process of rupture resolution may lead to beneficial outcomes and serve as a corrective emotional experience. The article describes unique processes of alliance rupture resolution inherent in animal-assisted psychotherapy (AAP). Building on Safran and Muran's model and on clinical examples, the article describes strategies for identifying ruptures in AAP and techniques for repairing them to facilitate a corrective experience in treatment. Implications for clinical practice and future research are discussed.

  8. Correction of a mutilated dentition with mini-implants as anchorage.

    PubMed

    Hyun, Jae-Man; Kim, Tae-Woo

    2010-11-01

    The patient was an adolescent boy, aged 15.6 years, with a mutilated dentition. He had extrusion of the maxillary left first molar because of loss of the mandibular first molar and lingual tilting and rotation of the mandibular second molars. Both left and right second molars were in scissors-bite that was more severe on the left side. By using mini-implants and a TPA with hooks, a 3-mm intrusion was successfully made on the maxillary left first molar. This provided room for mesial movement of the mandibular left second molar. The second molar was protracted into the space of the missing first molar, and the mandibular left third molar was positioned in place of the second molar. The second molars scissors-bite was corrected. Active treatment took 45 months, and the treatment result remained stable 2 years after debonding. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  9. Alcohol Production, Prevention Strategies, and Inmate Knowledge About the Risk for Botulism From Pruno Consumption in a Correctional Facility--Arizona, 2013.

    PubMed

    Adams, Laura E; Yasmin, Seema; Briggs, Graham; Redden, Kore; Silvas, Suzanne; Anderson, Shoana; Weiss, Joli; Tsang, Clarisse A; Henke, Evan; Francies, Jessica; Herrick, Kristen; Lira, Rosa; Livar, Eugene; Thompson, Gerald; Sunenshine, Rebecca; Robinson, Byron F; Bisgard, Kristine M; Komatsu, Kenneth K

    2015-10-01

    During July to November 2012, two botulism outbreaks (12 cases total) occurred in one all-male prison; both were associated with illicitly brewed alcohol (pruno) consumption. Inmate surveys were conducted to evaluate and develop prevention and education strategies. Qualitative surveys with open-ended questions were performed among inmates from rooms where outbreaks occurred to learn about pruno consumption. Quantitative surveys assessed knowledge gained after the outbreaks and preferred information sources. For the quantitative surveys, 250 inmates were randomly selected by bed from across the correctional facility and 164 inmates were interviewed. Only 24% of inmates reported any botulism knowledge before the outbreaks and education outreach, whereas 73% reported knowledge after the outbreaks (p < .01). Preferred information sources included handouts/fliers (52%) and the prison television channel (32%). © The Author(s) 2015.

  10. Dynamic Trajectory Extraction from Stereo Vision Using Fuzzy Clustering

    NASA Astrophysics Data System (ADS)

    Onishi, Masaki; Yoda, Ikushi

    In recent years, many human tracking researches have been proposed in order to analyze human dynamic trajectory. These researches are general technology applicable to various fields, such as customer purchase analysis in a shopping environment and safety control in a (railroad) crossing. In this paper, we present a new approach for tracking human positions by stereo image. We use the framework of two-stepped clustering with k-means method and fuzzy clustering to detect human regions. In the initial clustering, k-means method makes middle clusters from objective features extracted by stereo vision at high speed. In the last clustering, c-means fuzzy method cluster middle clusters based on attributes into human regions. Our proposed method can be correctly clustered by expressing ambiguity using fuzzy clustering, even when many people are close to each other. The validity of our technique was evaluated with the experiment of trajectories extraction of doctors and nurses in an emergency room of a hospital.

  11. Simulation of arthroscopic surgery using MRI data

    NASA Technical Reports Server (NTRS)

    Heller, Geoffrey; Genetti, Jon

    1994-01-01

    With the availability of Magnetic Resonance Imaging (MRI) technology in the medical field and the development of powerful graphics engines in the computer world the possibility now exists for the simulation of surgery using data obtained from an actual patient. This paper describes a surgical simulation system which will allow a physician or a medical student to practice surgery on a patient without ever entering an operating room. This could substantially lower the cost of medial training by providing an alternative to the use of cadavers. This project involves the use of volume data acquired by MRI which are converted to polygonal form using a corrected marching cubes algorithm. The data are then colored and a simulation of surface response based on springy structures is performed in real time. Control for the system is obtained through the use of an attached analog-to-digital unit. A remote electronic device is described which simulates an imaginary tool having features in common with both arthroscope and laparoscope.

  12. Artificial Intelligence Application in Power Generation Industry: Initial considerations

    NASA Astrophysics Data System (ADS)

    Ismail, Rahmat Izaizi B.; Ismail Alnaimi, Firas B.; AL-Qrimli, Haidar F.

    2016-03-01

    With increased competitiveness in power generation industries, more resources are directed in optimizing plant operation, including fault detection and diagnosis. One of the most powerful tools in faults detection and diagnosis is artificial intelligence (AI). Faults should be detected early so correct mitigation measures can be taken, whilst false alarms should be eschewed to avoid unnecessary interruption and downtime. For the last few decades there has been major interest towards intelligent condition monitoring system (ICMS) application in power plant especially with AI development particularly in artificial neural network (ANN). ANN is based on quite simple principles, but takes advantage of their mathematical nature, non-linear iteration to demonstrate powerful problem solving ability. With massive possibility and room for improvement in AI, the inspiration for researching them are apparent, and literally, hundreds of papers have been published, discussing the findings of hybrid AI for condition monitoring purposes. In this paper, the studies of ANN and genetic algorithm (GA) application will be presented.

  13. Effect of diffusive and nondiffusive surfaces combinations on sound diffusion

    NASA Astrophysics Data System (ADS)

    Shafieian, Masoume; Kashani, Farokh Hodjat

    2010-05-01

    One of room acoustic goals, especially in small to medium rooms, is sound diffusion in low frequencies, which have been the subject of lots of researches. Sound diffusion is a very important consideration in acoustics because it minimizes the coherent reflections that cause problems. It also tends to make an enclosed space sound larger than it is. Diffusion is an excellent alternative or complement to sound absorption in acoustic treatment because it doesn’t really remove much energy, which means it can be used to effectively reduce reflections while still leaving an ambient or live sounding space. Distribution of diffusive and nondiffusive surfaces on room walls affect sound diffusion in room, but the amount, combination, and location of these surfaces are still the matter of question. This paper investigates effects of these issues on room acoustic frequency response in different parts of the room with different source-receiver locations. Room acoustic model based on wave method is used (implemented) which is very accurate and convenient for low frequencies in such rooms. Different distributions of acoustic surfaces on room walls have been introduced to the model and room frequency response results are calculated. For the purpose of comparison, some measurements results are presented. Finally for more smooth frequency response in small and medium rooms, some suggestions are made.

  14. DETAIL OF DOORWAY INTO ROOM 102. view TO SOUTH. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF DOORWAY INTO ROOM 102. view TO SOUTH. - Plattsburgh Air Force Base, Target Intelligence Training Building-Combat Center, Off Connecticut Road, east of Idaho Avenue, Plattsburgh, Clinton County, NY

  15. Quantum logic gates based on ballistic transport in graphene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dragoman, Daniela; Academy of Romanian Scientists, Splaiul Independentei 54, 050094 Bucharest; Dragoman, Mircea, E-mail: mircea.dragoman@imt.ro

    2016-03-07

    The paper presents various configurations for the implementation of graphene-based Hadamard, C-phase, controlled-NOT, and Toffoli gates working at room temperature. These logic gates, essential for any quantum computing algorithm, involve ballistic graphene devices for qubit generation and processing and can be fabricated using existing nanolithographical techniques. All quantum gate configurations are based on the very large mean-free-paths of carriers in graphene at room temperature.

  16. Status quo and current trends of operating room management in Germany.

    PubMed

    Baumgart, André; Schüpfer, Guido; Welker, Andreas; Bender, Hans-Joachim; Schleppers, Alexander

    2010-04-01

    Ongoing healthcare reforms in Germany have required strenuous efforts to adapt hospital and operating room organizations to the needs of patients, new technological developments, and social and economic demands. This review addresses the major developments in German operating room management research and current practice. The introduction of the diagnosis-related group system in 2003 has changed the incentive structure of German hospitals to redesign their operating room units. The role of operating room managers has been gradually changing in hospitals in response to the change in the reimbursement system. Operating room managers are today specifically qualified and increasingly externally hired staff. They are more and more empowered with authority to plan and control operating rooms as profit centers. For measuring performance, common perioperative performance indicators are still scarcely implemented in German hospitals. In 2008, a concerted time glossary was established to enable consistent monitoring of operating room performance with generally accepted process indicators. These key performance indicators are a consistent way to make a procedure or case - and also the effectiveness of the operating room management - more transparent. In the presence of increasing financial pressure, a hospital's executives need to empower an independent operating room management function to achieve the hospital's economic goals. Operating room managers need to adopt evidence-based methods also from other scientific fields, for example management science and information technology, to further sustain operating room performance.

  17. Crisis Management of Accidental Extubation in a Prone-Positioned Patient with Klippel-Feil Syndrome.

    PubMed

    Spond, Matthew; Burns, Tyler; Rosenbaum, Thea; Lienhart, Kristen

    2016-06-15

    We present the case of an accidental extubation in a prone-positioned patient with a challenging airway because of Klippel-Feil syndrome and previous cervical spine fusions. The surgical procedure was well underway when this occurred, which added substantially to the difficulties produced by this event. We herein highlight the corrective steps we took in our case. We also recommend the need for a comprehensive preoperative briefing with all operating room personnel together with an action plan for how to prevent this particular scenario.

  18. Experimental system for the control of surgically induced infections, operating and maintenance instructions D203613-004

    NASA Technical Reports Server (NTRS)

    Tevebaugh, M. D.

    1971-01-01

    An experimental portable system used to control surgically induced infections is described. The system consists of a portable clean room comprised of a laminar flow filter system consistent with Federal standards; a helmet-shoulder pad assembly; a communication system; a helmet ventilation system; a transparent walled enclosure; and surgical gowns. Guidelines for the set up and operation of such equipment are given along with corrective steps to use in case of system malfunctions. Cleaning procedures, maintenance requirements, and disassembly and transfer particulars are included.

  19. The Polychromatic Laser Guide Star: the ELP-OA demonstrator at Observatoire de Haute Provence

    NASA Astrophysics Data System (ADS)

    Foy, R.; Chatagnat, M.; Dubet, D.; Éric, P.; Eysseric, J.; Foy, F.-C.; Fusco, T.; Girard, J.; Laloge, A.; Le van Suu, A.; Messaoudi, B.; Perruchot, S.; Richaud, P.; Richaud, Y.; Rondeau, X.; Tallon, M.; Thiébaut, É.; Boër, M.

    2007-07-01

    The correction of the tilt for adaptive optics devices from the only laser guide star can be done with the polychromatic laser guide star. We report the progress of the first demonstrator of the implementation of this concept, at Observatoire de Haute-Provence. We review the last steps of the feasibility studies, the optimization of the laser parameters, and the studies of the implementation at the OHP 1.52m telescope, including the beam propagation to the lasers room to the mesosphere and the algorithms for tip-tilt measurements.

  20. The role of technology in clinical trials using stereotactic body radiotherapy

    PubMed Central

    Romero, Alejandra Méndez; Heijmen, Ben J M

    2017-01-01

    Stereotactic body radiotherapy is a highly technology-driven treatment modality. The wider availability of in-room imaging and advanced radiotherapy delivery techniques has led to more institutions offering stereotactic ablative therapy (SABR). While some technological challenges remain, the crucial point for the next generation of SABR clinical trials is that today's technology is used correctly and close to its optimal potential for accuracy. The credentialing procedure of SABR needs to be extensive, but this investment will benefit the trial itself, the patients and the professionals involved. PMID:28055252

  1. Tunable and high-purity room temperature single-photon emission from atomic defects in hexagonal boron nitride

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grosso, Gabriele; Moon, Hyowon; Lienhard, Benjamin

    Two-dimensional van der Waals materials have emerged as promising platforms for solid-state quantum information processing devices with unusual potential for heterogeneous assembly. Recently, bright and photostable single photon emitters were reported from atomic defects in layered hexagonal boron nitride (hBN), but controlling inhomogeneous spectral distribution and reducing multi-photon emission presented open challenges. Here, we demonstrate that strain control allows spectral tunability of hBN single photon emitters over 6 meV, and material processing sharply improves the single photon purity. We observe high single photon count rates exceeding 7 × 10 6 counts per second at saturation, after correcting for uncorrelated photonmore » background. Furthermore, these emitters are stable to material transfer to other substrates. High-purity and photostable single photon emission at room temperature, together with spectral tunability and transferability, opens the door to scalable integration of high-quality quantum emitters in photonic quantum technologies.« less

  2. Tunable and high-purity room temperature single-photon emission from atomic defects in hexagonal boron nitride

    DOE PAGES

    Grosso, Gabriele; Moon, Hyowon; Lienhard, Benjamin; ...

    2017-09-26

    Two-dimensional van der Waals materials have emerged as promising platforms for solid-state quantum information processing devices with unusual potential for heterogeneous assembly. Recently, bright and photostable single photon emitters were reported from atomic defects in layered hexagonal boron nitride (hBN), but controlling inhomogeneous spectral distribution and reducing multi-photon emission presented open challenges. Here, we demonstrate that strain control allows spectral tunability of hBN single photon emitters over 6 meV, and material processing sharply improves the single photon purity. We observe high single photon count rates exceeding 7 × 10 6 counts per second at saturation, after correcting for uncorrelated photonmore » background. Furthermore, these emitters are stable to material transfer to other substrates. High-purity and photostable single photon emission at room temperature, together with spectral tunability and transferability, opens the door to scalable integration of high-quality quantum emitters in photonic quantum technologies.« less

  3. Development, validation and testing of a nursing home to emergency room transfer checklist.

    PubMed

    Tsai, Hsiu-Hsin; Tsai, Yun-Fang

    2018-01-01

    To develop and test the feasibility of an instrument to support patients' nursing home to emergency room transfer. Transfers from a nursing home care facility to an acute care facility such as a hospital emergency room are common. However, the prevalence of an information gap for transferring residents' health data to acute care facility is high. An evidence-based transfer instrument, which could fill this gap, is lacking. Development of a nursing home to emergency room transfer checklist, validation of items using the Delphi method and testing the feasibility and benefits of using the nursing home to emergency room transfer checklist. Items were developed based on qualitative data from previous research. Delphi validation, retrospective chart review (baseline data) and a 6-month prospective study design were applied to test the feasibility of using the checklist. Variables for testing the feasibility of the checklist included residents' 30-day readmission rate and length of hospital stay. Development of the nursing home to emergency room transfer checklist resulted in four main parts: (i) demographic data of the nursing home resident; (ii) critical data for nursing home to emergency room transfer; (iii) contact information and (iv) critical data for emergency room to nursing home transfer. Two rounds of Delphi validation resulted in a mean score (standard deviation) ranging from 4.39 (1.13)-4.98 (.15). Time required to complete the checklist was 3-5 min. Use of the nursing home to emergency room transfer checklist resulted in a 30-day readmission rate of 13.4%, which was lower than the baseline rate of 15.9%. The nursing home to emergency room transfer checklist was developed for transferring nursing home residents to an emergency room. The instrument was found to be an effective tool for this process. Use of the nursing home to emergency room transfer checklist for nursing home transfers could fill the information gap that exists when transferring older adults between facilities such as nursing homes and hospitals. © 2017 John Wiley & Sons Ltd.

  4. 2. CONTROL ROOM INTERIOR, CONSOLE AND MONITORS. Looking west. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. CONTROL ROOM INTERIOR, CONSOLE AND MONITORS. Looking west. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Control Center, Test Area 1-115, near Altair & Saturn Boulevards, Boron, Kern County, CA

  5. 2. Detail of panel in generator room, building 501, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Detail of panel in generator room, building 501, looking north - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  6. 14. Machine room, building 501, underground structure, May 11, 1956, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Machine room, building 501, underground structure, May 11, 1956, looking east - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  7. DETAIL OF DOORWAY INTO COMBAT INTELLIGENCE ROOM. view TO WEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF DOORWAY INTO COMBAT INTELLIGENCE ROOM. view TO WEST. - Plattsburgh Air Force Base, Target Intelligence Training Building-Combat Center, Off Connecticut Road, east of Idaho Avenue, Plattsburgh, Clinton County, NY

  8. Telephone equipment room, showing channel terminal bank with vacuum tubes. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Telephone equipment room, showing channel terminal bank with vacuum tubes. View to east - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  9. 24. VIEW OF EQUIPMENT ROOM WITH TRIPLELOCK RECOMPRESSION CHAMBER, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. VIEW OF EQUIPMENT ROOM WITH TRIPLE-LOCK RECOMPRESSION CHAMBER, LOOKING SOUTHWEST - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  10. Final Status Survey Report for Corrective Action Unit 117 - Pluto Disassembly Facility, Building 2201, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeremy Gwin and Douglas Frenette

    This document contains the process knowledge, radiological data and subsequent statistical methodology and analysis to support approval for the radiological release of Corrective Action Unit (CAU) 117 – Pluto Disassembly Facility, Building 2201 located in Area 26 of the Nevada National Security Site (NNSS). Preparations for release of the building began in 2009 and followed the methodology described in the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). MARSSIM is the DOE approved process for release of Real Property (buildings and landmasses) to a set of established criteria or authorized limits. The pre-approved authorized limits for surface contamination values andmore » corresponding assumptions were established by DOE O 5400.5. The release criteria coincide with the acceptance criteria of the U10C landfill permit. The U10C landfill is the proposed location to dispose of the radiologically non-impacted, or “clean,” building rubble following demolition. However, other disposition options that include the building and/or waste remaining at the NNSS may be considered providing that the same release limits apply. The Final Status Survey was designed following MARSSIM guidance by reviewing historical documentation and radiological survey data. Following this review a formal radiological characterization survey was performed in two phases. The characterization revealed multiple areas of residual radioactivity above the release criteria. These locations were remediated (decontaminated) and then the surface activity was verified to be less than the release criteria. Once remediation efforts had been successfully completed, a Final Status Survey Plan (10-015, “Final Status Survey Plan for Corrective Action Unit 117 – Pluto Disassembly Facility, Building 2201”) was developed and implemented to complete the final step in the MARSSIM process, the Final Status Survey. The Final Status Survey Plan consisted of categorizing each individual room into one of three categories: Class 1, Class 2 or Class 3 (a fourth category is a “Non-Impacted Class” which in the case of Building 2201 only pertained to exterior surfaces of the building.) The majority of the rooms were determined to fall in the less restrictive Class 3 category, however, Rooms 102, 104, 106, and 107 were identified as containing Class 1 and 2 areas. Building 2201 was divided into “survey units” and surveyed following the requirements of the Final Status Survey Plan for each particular class. As each survey unit was completed and documented, the survey results were evaluated. Each sample (static measurement) with units of counts per minute (cpm) was corrected for the appropriate background and converted to a value with units of dpm/100 cm2. With a surface contamination value in the appropriate units, it was compared to the surface contamination limits, or in this case the derived concentration guideline level (DCGLw). The appropriate statistical test (sign test) was then performed. If the survey unit was statistically determined to be below the DCGLw, then the survey unit passed and the null hypothesis (that the survey unit is above limits) was rejected. If the survey unit was equal to or below the critical value in the sign test, the null hypothesis was not rejected. This process was performed for all survey units within Building 2201. A total of thirty-three “Class 1,” four “Class 2,” and one “Class 3” survey units were developed, surveyed, and evaluated. All survey units successfully passed the statistical test. Building 2201 meets the release criteria commensurate with the Waste Acceptance Criteria (for radiological purposes) of the U10C landfill permit residing within NNSS boundaries. Based on the thorough statistical sampling and scanning of the building’s interior, Building 2201 may be considered radiologically “clean,” or free of contamination.« less

  11. Internet publicity of data problems in the bioscience literature correlates with enhanced corrective action

    PubMed Central

    2014-01-01

    Several online forums exist to facilitate open and/or anonymous discussion of the peer-reviewed scientific literature. Data integrity is a common discussion topic, and it is widely assumed that publicity surrounding such matters will accelerate correction of the scientific record. This study aimed to test this assumption by examining a collection of 497 papers for which data integrity had been questioned either in public or in private. As such, the papers were divided into two sub-sets: a public set of 274 papers discussed online, and the remainder a private set of 223 papers not publicized. The sources of alleged data problems, as well as criteria for defining problem data, and communication of problems to journals and appropriate institutions, were similar between the sets. The number of laboratory groups represented in each set was also similar (75 in public, 62 in private), as was the number of problem papers per laboratory group (3.65 in public, 3.54 in private). Over a study period of 18 months, public papers were retracted 6.5-fold more, and corrected 7.7-fold more, than those in the private set. Parsing the results by laboratory group, 28 laboratory groups in the public set had papers which received corrective action, versus 6 laboratory groups in the private set. For those laboratory groups in the public set with corrected/retracted papers, the fraction of their papers acted on was 62% of those initially flagged, whereas in the private set this fraction was 27%. Such clustering of actions suggests a pattern in which correction/retraction of one paper from a group correlates with more corrections/retractions from the same group, with this pattern being stronger in the public set. It is therefore concluded that online discussion enhances levels of corrective action in the scientific literature. Nevertheless, anecdotal discussion reveals substantial room for improvement in handling of such matters. PMID:24765564

  12. Design and analysis of a hemi-anechoic chamber at Michigan Technological University

    NASA Astrophysics Data System (ADS)

    Dreyer, Jason; Jangale, Ashish; Rao, Mohan D.

    2005-09-01

    A four-wheel chassis roll dynamometer test facility was installed on the campus of Michigan Technological University (MTU). The chassis dynamometer was enclosed in a soundproof hem-anechoic room in order to conduct noise radiation measurements on test vehicles. All surfaces of the room, except the floor and control room window, were acoustically treated with donated tetrahedral acoustic cones and panels. The acoustic absorption properties of these materials were characterized through reverberation chamber and impedance tube testing, and the effects of air gaps, cone orientation, and cone mounting materials were qualitatively evaluated. The design of the wall, ceiling, and door treatments of the chamber was based on the sound absorption properties of these materials, in addition to spatial constraints and cost considerations. The treated chamber acoustics were predicted based on the amount of acoustic material that could be applied to given chamber dimensions and would still preserve the functionality of the room. These predictions were validated through evaluation of the actual room treatment based on average reverberation time at 100-Hz third-octave band, free sound field characteristic 6-dB reduction in sound pressure level (SPL) per doubling in distance from source, noise reduction at the chamber boundaries, and background SPL Noise Criteria (NC) Rating.

  13. Ten years maintaining MACAO-VLTI units in operation in the Very Large Telescope at Paranal Observatory

    NASA Astrophysics Data System (ADS)

    Salgado, F.; Hudepohl, G.

    2016-07-01

    More than 10 years have already passed since the first Multiple Application Curvature Adaptive Optics (MACAO) facilities got the first light in UT2 the 18th of April, 2003, in the Very Large Telescope (VLT) at Paranal Observatory. The achievable image sharpness of a ground-based telescope is normally limited by the effect of atmospheric turbulence. However, with Adaptive Optics (AO) techniques, this major drawback can be overcome so that the telescope produces images that are as sharp as theoretically possible, i.e., as if they were taken from space. [1] The intention of this document is summarize in few pages some highlights related with the activities needed to keep MACAO units in operation. Some statistics of problems based in Action Remedy tool is included, showing how through these years the number of problems has been reduced, even when there are still some unsolved ones. Some lessons have been learned and there are others one to learn. Corrective and predictive maintenance performed are shown too like the current measurements, transfer functions measurements, thermography pictures, health checks measuring interaction matrix and flat vectors to detect dead APDs or short circuits in the DM, etc. Some forced interventions are included as well like the removal of the cabinets from Coude rooms to avoid that acoustic noise and vibrations perturb the operations, the deformable mirrors reached by cooling leaks and a mirror that got rusty are shown too. Well knowledge of the system, good interaction between different disciplines groups to perform corrective and preventive maintenance seems to be key aspects of keeping it under control and operative during all these years leading to this good result.

  14. Estimating the Occupational Morbidity for Migrant and Seasonal Farmworkers in New York State: a Comparison of Two Methods

    PubMed Central

    Earle-Richardson, Giulia B.; Brower, Melissa A.; Jones, Amanda M.; May, John J.; Jenkins, Paul L.

    2008-01-01

    Purpose To compare occupational morbidity estimates for migrant and seasonal farmworkers obtained from survey methods versus chart review methods, and to estimate the proportion of morbidity treated at federally recognized migrant health centers (MHCs) in a highly agricultural region of New York. Methods Researchers simultaneously conducted: a) an occupational injury and illness survey among agricultural workers; b) MHC chart review; and c) hospital emergency room (ER) chart reviews. Results Of the 24 injuries reported by 550 survey subjects, 54.2% received treatment MHCs 16.7% at ERs, 16.7% at some other facility, and 12.5% were untreated. For injuries treated at MHCs or ERs, the incidence density based on survey methods was 29.3 injuries per 10,000 worker-weeks versus 27.4 by chart review. The standardized morbidity ratio (SMR) for this comparison was 1.07 (95% CI = 0.65 – 1.77). Conclusion Survey data indicate that 71% of agricultural injury and illness can be captured with MHC and ER chart review. MHC and ER incidence density estimates show strong correspondence between the two methods. A chart review-based surveillance system, in conjunction with a correction factor based on periodic worker surveys, would provide a cost-effective estimate of the occupational illness and injury rate in this population. PMID:18063238

  15. Preliminary results in large bone segmentation from 3D freehand ultrasound

    NASA Astrophysics Data System (ADS)

    Fanti, Zian; Torres, Fabian; Arámbula Cosío, Fernando

    2013-11-01

    Computer Assisted Orthopedic Surgery (CAOS) requires a correct registration between the patient in the operating room and the virtual models representing the patient in the computer. In order to increase the precision and accuracy of the registration a set of new techniques that eliminated the need to use fiducial markers have been developed. The majority of these newly developed registration systems are based on costly intraoperative imaging systems like Computed Tomography (CT scan) or Magnetic resonance imaging (MRI). An alternative to these methods is the use of an Ultrasound (US) imaging system for the implementation of a more cost efficient intraoperative registration solution. In order to develop the registration solution with the US imaging system, the bone surface is segmented in both preoperative and intraoperative images, and the registration is done using the acquire surface. In this paper, we present the a preliminary results of a new approach to segment bone surface from ultrasound volumes acquired by means 3D freehand ultrasound. The method is based on the enhancement of the voxels that belongs to surface and its posterior segmentation. The enhancement process is based on the information provided by eigenanalisis of the multiscale 3D Hessian matrix. The preliminary results shows that from the enhance volume the final bone surfaces can be extracted using a singular value thresholding.

  16. Interior of exercise room created by enclosing former dance floor. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior of exercise room created by enclosing former dance floor. - U.S. Naval Base, Pearl Harbor, Bloch Recreation Center & Arena, Between Center Drive & North Road near Nimitz Gate, Pearl City, Honolulu County, HI

  17. 50. Representative office, room 2024, second floor, Dwing, building 500, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. Representative office, room 2024, second floor, D-wing, building 500, looking west - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  18. 55. Room BF9, paper shredding facility, basement level, building 500, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    55. Room BF-9, paper shredding facility, basement level, building 500, looking east - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  19. 14. INTERIOR VIEW OF PROPELLER STAND CONTROL ROOM. WrightPatterson ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. INTERIOR VIEW OF PROPELLER STAND CONTROL ROOM. - Wright-Patterson Air Force Base, Area B, Building No. 20A, Propeller Test Complex, Seventh Street, from E to G Streets, Dayton, Montgomery County, OH

  20. 125. TRANSFORMER SUBSTATIONS ON NORTH SIDE OF TRANSFORMER ROOM (112), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    125. TRANSFORMER SUBSTATIONS ON NORTH SIDE OF TRANSFORMER ROOM (112), FACING SOUTH - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. 10. VIEW, LOOKING NORTHWEST FROM LEFT TO RIGHT, SHOWING PUMP ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. VIEW, LOOKING NORTHWEST FROM LEFT TO RIGHT, SHOWING PUMP ROOM AND DRESSING ROOM - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  2. OFFICE AND INSTRUMENT ROOM SOUTH OF THE WEST TANK ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    OFFICE AND INSTRUMENT ROOM SOUTH OF THE WEST TANK - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Liquid Oxygen & Nitrogen Storage Tank Farm, Intersection of Altair & Jupiter Boulevards, Boron, Kern County, CA

  3. 7. INTERIOR, STEEL BLAST DOORS, INSTRUMENTATION ROOM. Edwards Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. INTERIOR, STEEL BLAST DOORS, INSTRUMENTATION ROOM. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-4, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  4. 5. ENGINE TEST CELL BUILDING INTERIOR. CENTRAL ROOM ON MAIN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. ENGINE TEST CELL BUILDING INTERIOR. CENTRAL ROOM ON MAIN FLOOR. LOOKING NORTHWEST. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA

  5. Field and laboratory studies of moving and temporally variable noise sources (aircraft); perception of location, movement, and direction.

    PubMed

    Gunn, W J; Shigehisa, T; Shepherd, W T

    1979-10-01

    The conditions were examined under which more valid and reliable estimates could be made of the effects of aircraft noise on people. In Exper. 1, 12 Ss in 2 different houses directly under the flight path of a major airport (JFK) indicated 1 of 12 possible flight paths (4 directly overhead and 8 to one side) for each of 3 jet aircraft flyovers: 3% of cases in House A and 56% in House B (which had open windows) were correctly identified. Despite judgment inaccuracy, Ss were more than moderately certain of the correctness of their judgments. In Exper. II. Ss either inside or outside of 2 houses in Wallops Station, Virginia, indicated on diagrams the direction of flyovers. Each of 4 aircraft (Boeing 737, C-54, UE-1 helicopter, Queenaire) made 8 flyovers directly over the houses and 8 to one side. Windows were either open or closed. All flyovers and conditions were counterbalanced. All sound sources under all conditions were usually judged to be overhead and moving, but for Ss indoors with windows closed the to-the-side flyovers were judged to be off to the side in 24% of cases. Outdoor Ss reported correct direction in 75% of cases while indoor Ss were correct in only 25% (windows open) or 18% (windows closed). Judgments "to the side" were significantly better (p = less than .02) with windows open vs closed, while with windows closed judgments were significantly better (p = less than .05) for flyovers overhead vs to the side. In Exper. III, Ss localized in azimuth and in the vertical plane recorded noises (10 1-oct noise bands of CF = 28.12 c/s - 14.4kc/s, spoken voice, and jet aircraft takeoffs and landings), presented through 1, 2, or 4 floor-level loudspeakers at each corner of a simulated living room (4.2 x 5.4m)built inside an IAC soundproof room. Aircraft noises presented by 4 loudspeakers were localized as "directly" overhead 80% of the time and "generally overhead" about 90% of the time; other sounds were so localized about 50% and 75% of the time respectively. Through only 2 loudspeakers, aircraft noises were localized 25-36 degrees above horizontal. Implications are that acoustic realism can be achieved in simulated aircraft overflights and that future laboratory noise-effects research should incorporate the required conditions.

  6. 3D reconstruction and spatial auralization of the "Painted Dolmen" of Antelas

    NASA Astrophysics Data System (ADS)

    Dias, Paulo; Campos, Guilherme; Santos, Vítor; Casaleiro, Ricardo; Seco, Ricardo; Sousa Santos, Beatriz

    2008-02-01

    This paper presents preliminary results on the development of a 3D audiovisual model of the Anta Pintada (painted dolmen) of Antelas, a Neolithic chamber tomb located in Oliveira de Frades and listed as Portuguese national monument. The final aim of the project is to create a highly accurate Virtual Reality (VR) model of this unique archaeological site, capable of providing not only visual but also acoustic immersion based on its actual geometry and physical properties. The project started in May 2006 with in situ data acquisition. The 3D geometry of the chamber was captured using a Laser Range Finder. In order to combine the different scans into a complete 3D visual model, reconstruction software based on the Iterative Closest Point (ICP) algorithm was developed using the Visualization Toolkit (VTK). This software computes the boundaries of the room on a 3D uniform grid and populates its interior with "free-space nodes", through an iterative algorithm operating like a torchlight illuminating a dark room. The envelope of the resulting set of "free-space nodes" is used to generate a 3D iso-surface approximating the interior shape of the chamber. Each polygon of this surface is then assigned the acoustic absorption coefficient of the corresponding boundary material. A 3D audiovisual model operating in real-time was developed for a VR Environment comprising head-mounted display (HMD) I-glasses SVGAPro, an orientation sensor (tracker) InterTrax 2 with 3 Degrees Of Freedom (3DOF) and stereo headphones. The auralisation software is based on a geometric model. This constitutes a first approach, since geometric acoustics have well-known limitations in rooms with irregular surfaces. The immediate advantage lies in their inherent computational efficiency, which allows real-time operation. The program computes the early reflections forming the initial part of the chamber's impulse response (IR), which carry the most significant cues for source localisation. These early reflections are processed through Head Related Transfer Functions (HRTF) updated in real-time according to the orientation of the user's head, so that sound waves appear to come from the correct location in space, in agreement with the visual scene. The late-reverberation tail of the IR is generated by an algorithm designed to match the reverberation time of the chamber, calculated from the actual acoustic absorption coefficients of its surfaces. The sound output to the headphones is obtained by convolving the IR with anechoic recordings of the virtual audio source.

  7. How Clean Are Hotel Rooms? Part I: Visual Observations vs. Microbiological Contamination.

    PubMed

    Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay

    2015-01-01

    Current evidence of hotel room cleanliness is based on observation rather than empirically based microbial assessment. The purpose of the study described here was to determine if observation provides an accurate indicator of cleanliness. Results demonstrated that visual assessment did not accurately predict microbial contamination. Although testing standards have not yet been established for hotel rooms and will be evaluated in Part II of the authors' study, potential microbial hazards included the sponge and mop (housekeeping cart), toilet, bathroom floor, bathroom sink, and light switch. Hotel managers should increase cleaning in key areas to reduce guest exposure to harmful bacteria.

  8. Ether-based nonflammable electrolyte for room temperature sodium battery

    NASA Astrophysics Data System (ADS)

    Feng, Jinkui; Zhang, Zhen; Li, Lifei; Yang, Jian; Xiong, Shenglin; Qian, Yitai

    2015-06-01

    Safety problem is one of the key points that hinder the development of room temperature sodium batteries. In this paper, four well-known nonflammable organic compounds, Trimethyl Phosphate (TMP), Tri(2,2,2-trifluoroethyl) phosphite (TFEP), Dimethyl Methylphosphonate (DMMP), Methyl nonafluorobuyl Ether (MFE), are investigated as nonflammable solvents in sodium batteries for the first time. Among them, MFE is stable towards sodium metal at room temperature. The electrochemical properties and electrode compatibility of MFE based electrolyte are investigated. Both Prussian blue cathode and carbon nanotube anode show good electrochemical performance retention in this electrolyte. The results suggest that MFE is a promising option as nonflammable electrolyte additive for sodium batteries.

  9. Local setup errors in image-guided radiotherapy for head and neck cancer patients immobilized with a custom-made device.

    PubMed

    Giske, Kristina; Stoiber, Eva M; Schwarz, Michael; Stoll, Armin; Muenter, Marc W; Timke, Carmen; Roeder, Falk; Debus, Juergen; Huber, Peter E; Thieke, Christian; Bendl, Rolf

    2011-06-01

    To evaluate the local positioning uncertainties during fractionated radiotherapy of head-and-neck cancer patients immobilized using a custom-made fixation device and discuss the effect of possible patient correction strategies for these uncertainties. A total of 45 head-and-neck patients underwent regular control computed tomography scanning using an in-room computed tomography scanner. The local and global positioning variations of all patients were evaluated by applying a rigid registration algorithm. One bounding box around the complete target volume and nine local registration boxes containing relevant anatomic structures were introduced. The resulting uncertainties for a stereotactic setup and the deformations referenced to one anatomic local registration box were determined. Local deformations of the patients immobilized using our custom-made device were compared with previously published results. Several patient positioning correction strategies were simulated, and the residual local uncertainties were calculated. The patient anatomy in the stereotactic setup showed local systematic positioning deviations of 1-4 mm. The deformations referenced to a particular anatomic local registration box were similar to the reported deformations assessed from patients immobilized with commercially available Aquaplast masks. A global correction, including the rotational error compensation, decreased the remaining local translational errors. Depending on the chosen patient positioning strategy, the remaining local uncertainties varied considerably. Local deformations in head-and-neck patients occur even if an elaborate, custom-made patient fixation method is used. A rotational error correction decreased the required margins considerably. None of the considered correction strategies achieved perfect alignment. Therefore, weighting of anatomic subregions to obtain the optimal correction vector should be investigated in the future. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Family-Based Crisis Intervention with Suicidal Adolescents in the Emergency Room: A Pilot Study

    ERIC Educational Resources Information Center

    Wharff, Elizabeth A.; Ginnis, Katherine M.; Ross, Abigail M.

    2012-01-01

    The prevailing model of care for psychiatric patients in the emergency room (ER) is evaluation and disposition, with little or no treatment provided. This article describes the results of a pilot study of a family-based crisis intervention (FBCI) for suicidal adolescents and their families in a large, urban pediatric ER. FBCI is an intervention…

  11. [Interface interconnection and data integration in implementing of digital operating room].

    PubMed

    Feng, Jingyi; Chen, Hua; Liu, Jiquan

    2011-10-01

    The digital operating-room, with highly integrated clinical information, is very important for rescuing lives of patients and improving quality of operations. Since equipments in domestic operating-rooms have diversified interface and nonstandard communication protocols, designing and implementing an integrated data sharing program for different kinds of diagnosing, monitoring, and treatment equipments become a key point in construction of digital operating room. This paper addresses interface interconnection and data integration for commonly used clinical equipments from aspects of hardware interface, interface connection and communication protocol, and offers a solution for interconnection and integration of clinical equipments in heterogeneous environment. Based on the solution, a case of an optimal digital operating-room is presented in this paper. Comparing with the international solution for digital operating-room, the solution proposed in this paper is more economical and effective. And finally, this paper provides a proposal for the platform construction of digital perating-room as well as a viewpoint for standardization of domestic clinical equipments.

  12. 5. "UNDERGROUND CONTROL ROOM AT TEST STAND 1A, DIRECTORATE OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. "UNDERGROUND CONTROL ROOM AT TEST STAND 1-A, DIRECTORATE OF MISSILE CAPTIVE TEST, EDWARDS AFB, 15 JAN 58, 3097.58." Two men working in the control room. Photo no. "3097 58; G-AFFTC 15 JAN 58, T.S. 1-A Control". - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Control Center, Test Area 1-115, near Altair & Saturn Boulevards, Boron, Kern County, CA

  13. FACILITY 363, INTERIOR. LIVING ROOM LOOKING TOWARDS BLACK LANAI. VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 363, INTERIOR. LIVING ROOM LOOKING TOWARDS BLACK LANAI. VIEW FACING NORTHWEST. - U.S. Naval Base, Pearl Harbor, Naval Housing Area Hospital Point, Pharmacist's Quarters Type, 13-16 First Street, Pearl City, Honolulu County, HI

  14. 83. DETAIL OF HONEYWELL AIRCONDITIONING CONTROLS IN SLC3E CONTROL ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    83. DETAIL OF HONEYWELL AIR-CONDITIONING CONTROLS IN SLC-3E CONTROL ROOM - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  15. 15. INTERIOR VIEW OF PROPELLER STAND VIEWING ROOM AND SCOPE. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. INTERIOR VIEW OF PROPELLER STAND VIEWING ROOM AND SCOPE. - Wright-Patterson Air Force Base, Area B, Building No. 20A, Propeller Test Complex, Seventh Street, from E to G Streets, Dayton, Montgomery County, OH

  16. 18. Topside facility, interior of facility manager's room, view towards ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Topside facility, interior of facility manager's room, view towards west. Lyon - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  17. 133. NITROGEN SUPPLY PANEL ON SOUTH WALL OF CONTROL ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    133. NITROGEN SUPPLY PANEL ON SOUTH WALL OF CONTROL ROOM (114), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. 143. MOBILE HIGH PRESSURE NITROGEN CART STORED IN CONTROL ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    143. MOBILE HIGH PRESSURE NITROGEN CART STORED IN CONTROL ROOM (214), LSB (BLDG. 751) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  19. 46. Communication equipment room, shock isolator air compressor at right, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. Communication equipment room, shock isolator air compressor at right, looking northeast - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  20. 137. VALVES ON SOUTH WALL OF LIQUID NITROGEN CONTROL ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    137. VALVES ON SOUTH WALL OF LIQUID NITROGEN CONTROL ROOM (115), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. 10. Credit BG. Interior of control and observation room at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Credit BG. Interior of control and observation room at Control and Recording Center Building 4221/E-22. - Jet Propulsion Laboratory Edwards Facility, Control & Recording Center, Edwards Air Force Base, Boron, Kern County, CA

  2. Time-out Rooms in Residential Treatment Centers

    ERIC Educational Resources Information Center

    Endres, V. Joseph; Goke, Douglas H.

    1973-01-01

    Among professionals, the use of the time-out room for the control of disturbed children in residential centers evokes varied and sometimes opposing opinions. This study is based on a questionnaire submitted to 50 residential treatment centers. (Editor)

  3. 11. ENGINE TEST CELL BUILDING INTERIOR. CONTROL ROOM FOR CELLS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. ENGINE TEST CELL BUILDING INTERIOR. CONTROL ROOM FOR CELLS 2 AND 4. LOOKING SOUTHEAST. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA

  4. 13. ENGINE TEST CELL BUILDING INTERIOR. EQUIPMENT ROOM SERVING CELLS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. ENGINE TEST CELL BUILDING INTERIOR. EQUIPMENT ROOM SERVING CELLS 2 AND 4. LOOKING SOUTHEAST. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA

  5. Development of Pasteuria penetrans in Meloidogyne javanica females as affected by constantly high vs fluctuating temperature in an in-vivo system.

    PubMed

    Darban, D A; Gowen, S R; Pembroke, B; Mahar, A N

    2005-03-01

    Growth room and glasshouse experiment was conducted to investigate the effect of constant and fluctuating temperatures on the development of Pasteuria penetrans a hyperparasite of root-knot nematodes. Tomato plants (Lycopersicon esculentum Mill) were inoculated with Meloidogyne javanica second-stage juveniles attached with endospores of P. penetrans and were grown in growth room at 26-29 degrees C and in glasshouse at 20-32 degrees C. The tomato plants were sampled from the growth room after 600 degree-days based on 17 degrees C/d, accumulating each day above a base temperature of 10 degrees C and from the glasshouse after 36 calendar days. Temperature affected the development of P. penetrans directly. The rate of development at constant temperature in growth room was faster than that in the glasshouse at fluctuating temperatures.

  6. Development of Pasteuria penetrans in Meloidogyne javanica females as affected by constantly high vs fluctuating temperature in an in-vivo system

    PubMed Central

    Darban, D.A.; Gowen, S.R.; Pembroke, B.; Mahar, A.N.

    2005-01-01

    Growth room and glasshouse experiment was conducted to investigate the effect of constant and fluctuating temperatures on the development of Pasteuria penetrans a hyperparasite of root-knot nematodes. Tomato plants (Lycopersicon esculentum Mill) were inoculated with Meloidogyne javanica second-stage juveniles attached with endospores of P. penetrans and were grown in growth room at 26–29 °C and in glasshouse at 20–32 °C. The tomato plants were sampled from the growth room after 600 degree-days based on 17 °C/d, accumulating each day above a base temperature of 10 °C and from the glasshouse after 36 calendar days. Temperature affected the development of P. penetrans directly. The rate of development at constant temperature in growth room was faster than that in the glasshouse at fluctuating temperatures. PMID:15682497

  7. An Inherent-Optical-Property-Centered Approach to Correct the Angular Effects in Water-Leaving Radiance

    DTIC Science & Technology

    2011-07-01

    10%. These results demonstrate that the IOP-based BRDF correction scheme (which is composed of the R„ model along with the IOP retrieval...distribution was averaged over 10 min 5. Validation of the lOP-Based BRDF Correction Scheme The IOP-based BRDF correction scheme is applied to both...oceanic and coastal waters were very consistent qualitatively and quantitatively and thus validate the IOP- based BRDF correction system, at least

  8. Achieving perceptually-accurate aural telepresence

    NASA Astrophysics Data System (ADS)

    Henderson, Paul D.

    Immersive multimedia requires not only realistic visual imagery but also a perceptually-accurate aural experience. A sound field may be presented simultaneously to a listener via a loudspeaker rendering system using the direct sound from acoustic sources as well as a simulation or "auralization" of room acoustics. Beginning with classical Wave-Field Synthesis (WFS), improvements are made to correct for asymmetries in loudspeaker array geometry. Presented is a new Spatially-Equalized WFS (SE-WFS) technique to maintain the energy-time balance of a simulated room by equalizing the reproduced spectrum at the listener for a distribution of possible source angles. Each reproduced source or reflection is filtered according to its incidence angle to the listener. An SE-WFS loudspeaker array of arbitrary geometry reproduces the sound field of a room with correct spectral and temporal balance, compared with classically-processed WFS systems. Localization accuracy of human listeners in SE-WFS sound fields is quantified by psychoacoustical testing. At a loudspeaker spacing of 0.17 m (equivalent to an aliasing cutoff frequency of 1 kHz), SE-WFS exhibits a localization blur of 3 degrees, nearly equal to real point sources. Increasing the loudspeaker spacing to 0.68 m (for a cutoff frequency of 170 Hz) results in a blur of less than 5 degrees. In contrast, stereophonic reproduction is less accurate with a blur of 7 degrees. The ventriloquist effect is psychometrically investigated to determine the effect of an intentional directional incongruence between audio and video stimuli. Subjects were presented with prerecorded full-spectrum speech and motion video of a talker's head as well as broadband noise bursts with a static image. The video image was displaced from the audio stimulus in azimuth by varying amounts, and the perceived auditory location measured. A strong bias was detectable for small angular discrepancies between audio and video stimuli for separations of less than 8 degrees for speech and less than 4 degrees with a pink noise burst. The results allow for the density of WFS systems to be selected from the required localization accuracy. Also, by exploiting the ventriloquist effect, the angular resolution of an audio rendering may be reduced when combined with spatially-accurate video.

  9. Tuberculosis prevention and control in large jails: a challenge to tuberculosis elimination.

    PubMed

    Roberts, Cheryl A; Lobato, Mark N; Bazerman, Lauri B; Kling, Ryan; Reichard, Audrey A; Hammett, Theodore M

    2006-02-01

    This study assessed the extent to which 20 large jail systems have implemented national recommendations for tuberculosis (TB) prevention and control in correctional facilities. Data were collected through questionnaires to jail medical directors and TB control directors, observation at the jails, and abstraction of medical records of inmates with TB disease and latent TB infection. Twenty percent of jail systems (4/20) had conducted an assessment of risk for TB transmission in their facilities, and 55% (11/20) monitored tuberculin skin test conversions of inmates and staff. Sixty-five percent (13/20) of jails had an aggregate record-keeping system for tracking TB status and treatment, which was usually paper based. Forty-five percent of jails (9/20) had policies to offer HIV counseling and testing to tuberculin skin test-positive patients, and 75% (15/20) screen HIV-infected inmates with chest radiographs. Three quarters of jails (15/20) had policies to always isolate patients with suspected or confirmed pulmonary TB in an airborne infection isolation room. Half of jails with airborne infection isolation rooms (6/12) conformed to Centers for Disease Control and Prevention (CDC) guidelines for monitoring negative pressure. Improvements are needed in conducting TB risk assessments and evaluations to determine priorities and reduce risk of transmission. Inadequate medical information systems are impeding TB control and evaluation efforts. Although HIV infection is the greatest cofactor for development of TB disease, jails have inadequate information on patients' HIV status to make informed decisions in screening and management of TB and latent TB infection. Jails need to improve the use of environmental controls.

  10. How Clean Are Hotel Rooms? Part II: Examining the Concept of Cleanliness Standards.

    PubMed

    Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay

    2015-01-01

    Hotel room cleanliness is based on observation and not on microbial assessment even though recent reports suggest that infections may be acquired while staying in hotel rooms. Exploratory research in the first part of the authors' study was conducted to determine if contamination of hotel rooms occurs and whether visual assessments are accurate indicators of hotel room cleanliness. Data suggested the presence of microbial contamination that was not reflective of visual assessments. Unfortunately, no standards exist for interpreting microbiological data and other indicators of cleanliness in hotel rooms. The purpose of the second half of the authors' study was to examine cleanliness standards in other industries to see if they might suggest standards in hotels. Results of the authors' study indicate that standards from other related industries do not provide analogous criteria, but do provide suggestions for further research.

  11. Localization of sound sources in a room with one microphone

    NASA Astrophysics Data System (ADS)

    Peić Tukuljac, Helena; Lissek, Hervé; Vandergheynst, Pierre

    2017-08-01

    Estimation of the location of sound sources is usually done using microphone arrays. Such settings provide an environment where we know the difference between the received signals among different microphones in the terms of phase or attenuation, which enables localization of the sound sources. In our solution we exploit the properties of the room transfer function in order to localize a sound source inside a room with only one microphone. The shape of the room and the position of the microphone are assumed to be known. The design guidelines and limitations of the sensing matrix are given. Implementation is based on the sparsity in the terms of voxels in a room that are occupied by a source. What is especially interesting about our solution is that we provide localization of the sound sources not only in the horizontal plane, but in the terms of the 3D coordinates inside the room.

  12. On the importance of early reflections for speech in rooms.

    PubMed

    Bradley, J S; Sato, H; Picard, M

    2003-06-01

    This paper presents the results of new studies based on speech intelligibility tests in simulated sound fields and analyses of impulse response measurements in rooms used for speech communication. The speech intelligibility test results confirm the importance of early reflections for achieving good conditions for speech in rooms. The addition of early reflections increased the effective signal-to-noise ratio and related speech intelligibility scores for both impaired and nonimpaired listeners. The new results also show that for common conditions where the direct sound is reduced, it is only possible to understand speech because of the presence of early reflections. Analyses of measured impulse responses in rooms intended for speech show that early reflections can increase the effective signal-to-noise ratio by up to 9 dB. A room acoustics computer model is used to demonstrate that the relative importance of early reflections can be influenced by the room acoustics design.

  13. Allocation of surgical procedures to operating rooms.

    PubMed

    Ozkarahan, I

    1995-08-01

    Reduction of health care costs is of paramount importance in our time. This paper is a part of the research which proposes an expert hospital decision support system for resource scheduling. The proposed system combines mathematical programming, knowledge base, and database technologies, and what is more, its friendly interface is suitable for any novice user. Operating rooms in hospitals represent big investments and must be utilized efficiently. In this paper, first a mathematical model similar to job shop scheduling models is developed. The model loads surgical cases to operating rooms by maximizing room utilization and minimizing overtime in a multiple operating room setting. Then a prototype expert system which replaces the expertise of the operations research analyst for the model, drives the modelbase, database, and manages the user dialog is developed. Finally, an overview of the sequencing procedures for operations within an operating room is also presented.

  14. Learning gestures for customizable human-computer interaction in the operating room.

    PubMed

    Schwarz, Loren Arthur; Bigdelou, Ali; Navab, Nassir

    2011-01-01

    Interaction with computer-based medical devices in the operating room is often challenging for surgeons due to sterility requirements and the complexity of interventional procedures. Typical solutions, such as delegating the interaction task to an assistant, can be inefficient. We propose a method for gesture-based interaction in the operating room that surgeons can customize to personal requirements and interventional workflow. Given training examples for each desired gesture, our system learns low-dimensional manifold models that enable recognizing gestures and tracking particular poses for fine-grained control. By capturing the surgeon's movements with a few wireless body-worn inertial sensors, we avoid issues of camera-based systems, such as sensitivity to illumination and occlusions. Using a component-based framework implementation, our method can easily be connected to different medical devices. Our experiments show that the approach is able to robustly recognize learned gestures and to distinguish these from other movements.

  15. Applying cost accounting to operating room staffing in otolaryngology: time-driven activity-based costing and outpatient adenotonsillectomy.

    PubMed

    Balakrishnan, Karthik; Goico, Brian; Arjmand, Ellis M

    2015-04-01

    (1) To describe the application of a detailed cost-accounting method (time-driven activity-cased costing) to operating room personnel costs, avoiding the proxy use of hospital and provider charges. (2) To model potential cost efficiencies using different staffing models with the case study of outpatient adenotonsillectomy. Prospective cost analysis case study. Tertiary pediatric hospital. All otolaryngology providers and otolaryngology operating room staff at our institution. Time-driven activity-based costing demonstrated precise per-case and per-minute calculation of personnel costs. We identified several areas of unused personnel capacity in a basic staffing model. Per-case personnel costs decreased by 23.2% by allowing a surgeon to run 2 operating rooms, despite doubling all other staff. Further cost reductions up to a total of 26.4% were predicted with additional staffing rearrangements. Time-driven activity-based costing allows detailed understanding of not only personnel costs but also how personnel time is used. This in turn allows testing of alternative staffing models to decrease unused personnel capacity and increase efficiency. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  16. The development and application of electronic information system for safety administration of newborns in the rooming-in care.

    PubMed

    Wang, Fang; Dong, Jian-Cheng; Chen, Jian-Rong; Wu, Hui-Qun; Liu, Man-Hua; Xue, Li-Ly; Zhu, Xiang-Hua; Wang, Jian

    2015-01-01

    To independently research and develop an electronic information system for safety administration of newborns in the rooming-in care, and to investigate the effects of its clinical application. By VS 2010 SQL SERVER 2005 database and adopting Microsoft visual programming tool, an interactive mobile information system was established, with integrating data, information and knowledge with using information structures, information processes and information technology. From July 2011 to July 2012, totally 210 newborns from the rooming-in care of the Obstetrics Department of the Second Affiliated Hospital of Nantong University were chosen and randomly divided into two groups: the information system monitoring group (110 cases) and the regular monitoring group (100 cases). Incidence of abnormal events and degree of satisfaction were recorded and calculated. ① The wireless electronic information system has four main functions including risk scaling display, identity recognition display, nursing round notes board and health education board; ② statistically significant differences were found between the two groups both on the active or passive discovery rate of abnormal events occurred in the newborns (P<0.05) and the satisfaction degree of the mothers and their families (P<0.05); ③ the system was sensitive and reliable, and the wireless transmission of information was correct and safety. The system is with high practicability in the clinic and can ensure the safety for the newborns with improved satisfactions.

  17. 11. CONTROL ROOM INTERIOR, SHOWING SEVERAL PERISCOPES. Looking north along ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. CONTROL ROOM INTERIOR, SHOWING SEVERAL PERISCOPES. Looking north along west wall. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  18. 11. CENTRAL ATLAS CONTROL CONSOLE IN SLC3W CONTROL ROOM. COMMUNICATIONS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. CENTRAL ATLAS CONTROL CONSOLE IN SLC-3W CONTROL ROOM. COMMUNICATIONS HEADSETS IN FOREGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  19. FACILITY 363, INTERIOR. KITCHEN AS SEEN FROM LIVING ROOM ENTRY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 363, INTERIOR. KITCHEN AS SEEN FROM LIVING ROOM ENTRY . VIEW FACING SOUTH. - U.S. Naval Base, Pearl Harbor, Naval Housing Area Hospital Point, Pharmacist's Quarters Type, 13-16 First Street, Pearl City, Honolulu County, HI

  20. 4. INSTRUMENT ROOM,INTERIOR, MAIN SPACE. Looking northeast. Edwards Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. INSTRUMENT ROOM,INTERIOR, MAIN SPACE. Looking northeast. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA

  1. 45. SAC conference room 2A8, second floor, Dwing, building 500, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. SAC conference room 2A8, second floor, D-wing, building 500, looking southeast - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  2. DETAIL OF DOORWAYS INTO ROOMS I18 (LEFT) AND 113 (RIGHT). ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF DOORWAYS INTO ROOMS I18 (LEFT) AND 113 (RIGHT). view TO NORTHWEST. - Plattsburgh Air Force Base, Target Intelligence Training Building-Combat Center, Off Connecticut Road, east of Idaho Avenue, Plattsburgh, Clinton County, NY

  3. Interior view to the southwest of Computer Room 157 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view to the southwest of Computer Room 157 - Over-the-Horizon Backscatter Radar Network, Mountain Home Air Force Operations Building, On Desert Street at 9th Avenue Mountain Home Air Force Base, Mountain Home, Elmore County, ID

  4. VIEW OF EAST SIDE OF FILTER ROOM/BATHHOUSE BUILDING S196, FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF EAST SIDE OF FILTER ROOM/BATHHOUSE BUILDING S-196, FACING SOUTHWEST. - U.S. Naval Base, Pearl Harbor, Outdoor Swimming Pool, Corner of Liscome Bay Street & St. Lo Avenue, Pearl City, Honolulu County, HI

  5. VIEW OF OUTDOOR SWIMMING POOL AND FILTER ROOM/ BATHHOUSE S196, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF OUTDOOR SWIMMING POOL AND FILTER ROOM/ BATHHOUSE S-196, FACING WEST. - U.S. Naval Base, Pearl Harbor, Outdoor Swimming Pool, Corner of Liscome Bay Street & St. Lo Avenue, Pearl City, Honolulu County, HI

  6. 9. VIEW, LOOKING NORTH FROM LEFT TO RIGHT, SHOWING MEDICAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. VIEW, LOOKING NORTH FROM LEFT TO RIGHT, SHOWING MEDICAL RESEARCH LABORATORY ANNEX, EXAMINING ROOM, AND EQUIPMENT ROOM - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  7. 13. VIEW, LOOKING WEST FROM LEFT TO RIGHT, SHOWING HIGH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. VIEW, LOOKING WEST FROM LEFT TO RIGHT, SHOWING HIGH PRESSURE AIR FLASK ROOM AND PUMP ROOM - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  8. 31. ENGINE ROOM LOOKING AFT ON STARBOARD SIDE SHOWING BOTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. ENGINE ROOM LOOKING AFT ON STARBOARD SIDE SHOWING BOTH CATERPILLAR DIESELS AND ONE GENERATOR. - U.S. Coast Guard Cutter WHITE PINE, U.S. Coast Guard 8th District Base, South Broad Street, Mobile, Mobile County, AL

  9. 15. Interior view of unoccupied controlled computer room looking at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Interior view of unoccupied controlled computer room looking at exit door and office; northwest corner of unoccupied portion; view to south. - Ellsworth Air Force Base, Mess & Administration Building, 2279 Risner Drive, Blackhawk, Meade County, SD

  10. Improving the accuracy of the diagnosis of schizophrenia by means of virtual reality.

    PubMed

    Sorkin, Anna; Weinshall, Daphna; Modai, Ilan; Peled, Avi

    2006-03-01

    The authors' goal was to improve the diagnosis of schizophrenia by using virtual reality technology to build a complex, multimodal environment in which cognitive functions can be studied (and measured) in parallel. The authors studied sensory integration within working memory by means of computer navigation through a virtual maze. The simulated journey consisted of a series of rooms, each of which included three doors. Each door was characterized by three features (color, shape, and sound), and a single combination of features--the door-opening rule--was correct. Subjects had to learn the rule and use it. The participants were 39 schizophrenic patients and 21 healthy comparison subjects. Upon completion, each subject was assigned a performance profile, including various error scores, response time, navigation ability, and strategy. A classification procedure based on the subjects' performance profile correctly predicted 85% of the schizophrenic patients (and all of the comparison subjects). Several performance variables showed significant correlations with scores on a standard diagnostic measure (Positive and Negative Syndrome Scale), suggesting potential use of these measurements for the diagnosis of schizophrenia. On the other hand, the patients did not show unusual repetition of response despite stimulus cessation (called "perseveration" in classical studies of schizophrenia), which is a common symptom of the disease. This deficit appeared only when the subjects did not receive proper explanation of the task. The ability to study multimodal performance simultaneously by using virtual reality technology opens new possibilities for the diagnosis of schizophrenia with objective procedures.

  11. TMSEG: Novel prediction of transmembrane helices.

    PubMed

    Bernhofer, Michael; Kloppmann, Edda; Reeb, Jonas; Rost, Burkhard

    2016-11-01

    Transmembrane proteins (TMPs) are important drug targets because they are essential for signaling, regulation, and transport. Despite important breakthroughs, experimental structure determination remains challenging for TMPs. Various methods have bridged the gap by predicting transmembrane helices (TMHs), but room for improvement remains. Here, we present TMSEG, a novel method identifying TMPs and accurately predicting their TMHs and their topology. The method combines machine learning with empirical filters. Testing it on a non-redundant dataset of 41 TMPs and 285 soluble proteins, and applying strict performance measures, TMSEG outperformed the state-of-the-art in our hands. TMSEG correctly distinguished helical TMPs from other proteins with a sensitivity of 98 ± 2% and a false positive rate as low as 3 ± 1%. Individual TMHs were predicted with a precision of 87 ± 3% and recall of 84 ± 3%. Furthermore, in 63 ± 6% of helical TMPs the placement of all TMHs and their inside/outside topology was correctly predicted. There are two main features that distinguish TMSEG from other methods. First, the errors in finding all helical TMPs in an organism are significantly reduced. For example, in human this leads to 200 and 1600 fewer misclassifications compared to the second and third best method available, and 4400 fewer mistakes than by a simple hydrophobicity-based method. Second, TMSEG provides an add-on improvement for any existing method to benefit from. Proteins 2016; 84:1706-1716. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. [How many patient transfer rooms are necessary for my OR suite? : Effect of the number of OR transfer rooms on waiting times and patient throughput in the OR - analysis by simulation].

    PubMed

    Messer, C; Zander, A; Arnolds, I V; Nickel, S; Schuster, M

    2015-12-01

    In most hospitals the operating rooms (OR) are separated from the rest of the hospital by transfer rooms where patients have to pass through for reasons of hygiene. In the OR transfer room patients are placed on the OR table before surgery and returned to the hospital bed after surgery. It could happen that the number of patients who need to pass through a transfer room at a certain point in time exceed the number of available transfer rooms. As a result the transfer rooms become a bottleneck where patients have to wait and which, in turn, may lead to delays in the OR suite. In this study the ability of a discrete event simulation to analyze the effect of the duration of surgery and the number of ORs on the number of OR transfer rooms needed was investigated. This study was based on a discrete event simulation model developed with the simulation software AnyLogic®. The model studied the effects of the number of OR transfer rooms on the processes in an OR suite of a community hospital by varying the number of ORs from one to eight and using different surgical portfolios. Probability distributions for the process duration of induction, surgery and recovery and transfer room processes were calculated on the basis of real data from the community hospital studied. Furthermore, using a generic simulation model the effect of the average duration of surgery on the number of OR transfer rooms needed was examined. The discrete event simulation model enabled the analysis of both quantitative as well as qualitative changes in the OR process and setting. Key performance indicators of the simulation model were patient throughput per day, the probability of waiting and duration of waiting time in front of OR transfer rooms. In the case of a community hospital with 1 transfer room the average proportion of patients waiting before entering the OR was 17.9 % ± 9.7 % with 3 ORs, 37.6 % ± 9.7 % with 5 ORs and 62.9 % ± 9.1 % with 8 ORs. The average waiting time of patients in the setting with 3 ORs was 3.1 ± 2.7 min, with 5 ORs 5.0 ± 5.8 min and with 8 ORs 11.5 ± 12.5 min. Based on this study the community hospital needs a second transfer room starting from 4 ORs so that there is no bottleneck for the subsequent OR processes. The average patient throughput in a setting with 4 ORs increased significantly by 0.3 patients per day when a second transfer room is available. The generic model showed a strong effect of the average duration of surgery on the number of transfer rooms needed. There was no linear correlation between the number of transfer rooms and the number of ORs. The shorter the average duration of surgery, the earlier an additional transfer room is required. Thus, hospitals with shorter duration of surgery and fewer ORs may need the same or more transfer rooms than a hospital with longer duration of surgery and more ORs. However, with respect to an economic analysis, the costs and benefits of installing additional OR transfer rooms need to be calculated using the profit margins of the specific hospital.

  13. Undergraduate training in neonatal resuscitation -- a modified approach.

    PubMed

    Bhat, B V; Biswal, N; Bhatia, B D; Nalini, P

    1993-01-01

    On one day in January 1993, in Pondicherry, India, prior to rounds in the labor room, professors trained 50 final year, undergraduate medical students at the Jawaharlal Institute of Postgraduate Medical Education and Research in neonatal resuscitation using a modified program of the neonatal advanced life support course. They compared their results with those from students in the March-April 1992 multiday course, which occurred after some students had finished their labor room rounds. In 1992, the pretest was administered after the theory lectures, while, in 1993, it was administered before the course, including the theory lectures, began. The 1992 students scored significantly higher on the pretest than did the 1993 students (e.g., score of 11-20, 73.3% vs. 0%; p .001). There was essentially no difference in posttest scores between the 2 groups, however. All the 1993 students did the resuscitation procedure on the mannequin on their own. 92% rated the content of the program and use of audiovisual aids to be optimum. The same percentage wanted the neonatal advanced life support program to last one day. About 33% wanted a short respite between lectures. The students identified the following messages to be important: early identification of the high risk neonate, correct resuscitation techniques, and use and misuse of drugs during resuscitation. They all considered the training to be adequate, informative, and applicable to real life during their labor room rounds and later as a basic physician. These findings indicated that the modified neonatal advanced life support course was effective and that professors should conduct it for all final year medical students before the student begin labor room rounds, ideally in one day.

  14. Is the Moon Illusion a Celestial Ames Demonstration?

    NASA Astrophysics Data System (ADS)

    Brecher, Kenneth

    2010-01-01

    To most naked eye observers, the Moon appears larger when seen near the horizon than it does when seen near the zenith. This "Moon Illusion” has been reported from as early as the fourth century BC and has been the subject of hundreds of papers and two books. Its explanation does not lie in the realm of physics (atmospheric refraction) or astronomy (eccentric lunar orbit) but, rather, in the realm of visual perception. Theories for the cause of the effect abound but, at present, there is no universally accepted explanation. Because the effect can be easily observed in many locations and during the course of an academic year, the moon illusion can provide a nice astronomical example that involves both direct observations and theoretical analysis. As part of the NSF funded "Project LITE: Light Inquiry Through Experiments", we have been developing inexpensive experiments and demonstrations that can be done at home. One of these is a miniature version of the classic "Ames Room". The life size version was originally developed by Adelbert Ames, Jr. and can be seen in many science museums. Our "digital” Ames Room has been designed to be printed on heavy paper using an inexpensive inkjet printer from a PDF file that is posted on the Project LITE web site http://lite.bu.edu and then cut and folded to make the room. When viewed through one wall using a commonly available door viewer, it dramatically demonstrates how the eye and brain system assesses the relative size of objects by making comparisons with the surrounding environment in which the objects are placed. In this presentation we will discuss some insights that the Ames Room provides that may offer clues to the correct explanation for the Moon Illusion. Project LITE is supported by the NSF through DUE Grant # 0715975.

  15. Pulmonary gas exchange efficiency during exercise breathing normoxic and hypoxic gas in adults born very preterm with low diffusion capacity.

    PubMed

    Duke, Joseph W; Elliott, Jonathan E; Laurie, Steven S; Beasley, Kara M; Mangum, Tyler S; Hawn, Jerold A; Gladstone, Igor M; Lovering, Andrew T

    2014-09-01

    Adults with a history of very preterm birth (<32 wk gestational age; PRET) have reduced lung function and significantly lower lung diffusion capacity for carbon monoxide (DLCO) relative to individuals born at term (CONT). Low DLCO may predispose PRET to diffusion limitation during exercise, particularly while breathing hypoxic gas because of a reduced O2 driving gradient and pulmonary capillary transit time. We hypothesized that PRET would have significantly worse pulmonary gas exchange efficiency [i.e., increased alveolar-to-arterial Po2 difference (AaDO2)] during exercise breathing room air or hypoxic gas (FiO2 = 0.12) compared with CONT. To test this hypothesis, we compared the AaDO2 in PRET (n = 13) with a clinically mild reduction in DLCO (72 ± 7% of predicted) and CONT (n = 14) with normal DLCO (105 ± 10% of predicted) pre- and during exercise breathing room air and hypoxic gas. Measurements of temperature-corrected arterial blood gases, and direct measure of O2 saturation (SaO2), were made prior to and during exercise at 25, 50, and 75% of peak oxygen consumption (V̇o2peak) while breathing room air and hypoxic gas. In addition to DLCO, pulmonary function and exercise capacity were significantly less in PRET. Despite PRET having low DLCO, no differences were observed in the AaDO2 or SaO2 pre- or during exercise breathing room air or hypoxic gas compared with CONT. Although our findings were unexpected, we conclude that reduced pulmonary function and low DLCO resulting from very preterm birth does not cause a measureable reduction in pulmonary gas exchange efficiency. Copyright © 2014 the American Physiological Society.

  16. FY15 Report on Thermomechanical Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Francis D.; Buchholz, Stuart

    2015-08-01

    Sandia is participating in the third phase of a United States (US)-German Joint Project that compares constitutive models and simulation procedures on the basis of model calculations of the thermomechanical behavior and healing of rock salt (Salzer et al. 2015). The first goal of the project is to evaluate the ability of numerical modeling tools to correctly describe the relevant deformation phenomena in rock salt under various influences. Among the numerical modeling tools required to address this are constitutive models that are used in computer simulations for the description of the thermal, mechanical, and hydraulic behavior of the host rockmore » under various influences and for the long-term prediction of this behavior. Achieving this goal will lead to increased confidence in the results of numerical simulations related to the secure disposal of radioactive wastes in rock salt. Results of the Joint Project may ultimately be used to make various assertions regarding stability analysis of an underground repository in salt during the operating phase as well as long-term integrity of the geological barrier in the post-operating phase A primary evaluation of constitutive model capabilities comes by way of predicting large-scale field tests. The Joint Project partners decided to model Waste Isolation Pilot Plant (WIPP) Rooms B & D which are full-scale rooms having the same dimensions. Room D deformed under natural, ambient conditions while Room B was thermally driven by an array of waste-simulating heaters (Munson et al. 1988; 1990). Existing laboratory test data for WIPP salt were carefully scrutinized and the partners decided that additional testing would be needed to help evaluate advanced features of the constitutive models. The German partners performed over 140 laboratory tests on WIPP salt at no charge to the US Department of Energy (DOE).« less

  17. Knowledge of the management of paediatric dental traumas by non-dental professionals in emergency rooms in South Araucanía, Temuco, Chile.

    PubMed

    Díaz, Jaime; Bustos, Luís; Herrera, Samira; Sepulveda, Jaqueline

    2009-12-01

    The objective of this study was to investigate the level of knowledge and attitudes regarding first aid for dental trauma in children (TDI) by non-dental professionals and paramedical technicians of hospital emergency rooms in the South Araucanía Health Service, Chile, which was attained through application of a survey. Samples were collected from people with occupations in the respective emergency rooms. The participants were 82 people that were interviewed using a questionnaire regarding management of dental trauma. Paramedic technicians, general and specialist doctors, and nurses were included in this survey. The appraisal covered diverse aspects: birth date, age, sex, years of experience in the emergency room, and questions regarding specific dental trauma topics, which focused on crown fractures, luxation injuries in permanent dentition, avulsion in primary and permanent teeth, and the respective emergency treatments. Of the participants, 78.1% reported to have been presented with a TDI patient. The majority (90.2%) had not received formal training on TDI. These results revealed a wide distribution of responses. The overall dental trauma knowledge among the participants was relatively poor. For crown fractures management 54.9% indicated that they would ask the affected child about the crown remnants. In regard to transport and storage medium of avulsed permanent teeth, only 9.8% of the participants answered correctly and 43.9% of respondents stated that they would not replant an avulsed permanent tooth, since that procedure is considered the responsibility of a dentist. The majority of the respondents were not knowledgeable regarding TDI or the management and benefits of timely care, particularly in cases of avulsed permanent teeth. Therefore, formal education and training on the topic is suggested during undergraduate studies.

  18. Design of a Tunable, Room Temperature, Continuous-Wave Terahertz Source and Detector using Silicon Waveguides

    DTIC Science & Technology

    2008-01-30

    that will use conventional diode- or hotomultiplier-tube-based optical detectors , which are xtremely sensitive . . HEATING AND FREE-CARRIER IMITATIONS...CONTRACT NUMBER IN-HOUSE Design of a tunable, room temperature, continuous-wave terahertz source and detector using silicon waveguides 5b. GRANT...B 261Design of a tunable, room temperature, continuous-wave terahertz source and detector using silicon waveguides T. Baehr-Jones,1,* M. Hochberg,1,3

  19. Conference room 211, adjacent to commander's quarters, with vault door ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Conference room 211, adjacent to commander's quarters, with vault door at right. Projection area at center is equipped with automatic security drapes. Projection room uses a 45 degree mirror to reflect the image onto the frosted glass screen. Door on far left leads to display area senior battle staff viewing bridge, and the commander's quarters - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  20. Immersive virtual reality-based training improves response in a simulated operating room fire scenario.

    PubMed

    Sankaranarayanan, Ganesh; Wooley, Lizzy; Hogg, Deborah; Dorozhkin, Denis; Olasky, Jaisa; Chauhan, Sanket; Fleshman, James W; De, Suvranu; Scott, Daniel; Jones, Daniel B

    2018-01-25

    SAGES FUSE curriculum provides didactic knowledge on OR fire prevention. The objective of this study is to evaluate the impact of an immersive virtual reality (VR)-based OR fire training simulation system in combination with FUSE didactics. The study compared a control with a simulation group. After a pre-test questionnaire that assessed the baseline knowledge, both groups were given didactic material that consists of a 10-min presentation and reading materials about precautions and stopping an OR fire from the FUSE manual. The simulation group practiced on the OR fire simulation for one session that consisted of five trials within a week from the pre-test. One week later, both groups were reassessed using a questionnaire. A week after the post-test both groups also participated in a simulated OR fire scenario while their performance was videotaped for assessment. A total of 20 subjects (ten per group) participated in this IRB approved study. Median test scores for the control group increased from 5.5 to 9.00 (p = 0.011) and for the simulation group it increased from 5.0 to 8.5 (p = 0.005). Both groups started at the same baseline (pre-test, p = 0.529) and reached similar level in cognitive knowledge (post-test, p = 0.853). However, when tested in the mock OR fire scenario, 70% of the simulation group subjects were able to perform the correct sequence of steps in extinguishing the simulated fire whereas only 20% subjects in the control group were able to do so (p = 0.003). The simulation group was better than control group in correctly identifying the oxidizer (p = 0.03) and ignition source (p = 0.014). Interactive VR-based hands-on training was found to be a relatively inexpensive and effective mode for teaching OR fire prevention and management scenarios.

  1. Preliminary Studies for a CBCT Imaging Protocol for Offline Organ Motion Analysis: Registration Software Validation and CTDI Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Falco, Maria Daniela, E-mail: mdanielafalco@hotmail.co; Fontanarosa, Davide; Miceli, Roberto

    2011-04-01

    Cone-beam X-ray volumetric imaging in the treatment room, allows online correction of set-up errors and offline assessment of residual set-up errors and organ motion. In this study the registration algorithm of the X-ray volume imaging software (XVI, Elekta, Crawley, United Kingdom), which manages a commercial cone-beam computed tomography (CBCT)-based positioning system, has been tested using a homemade and an anthropomorphic phantom to: (1) assess its performance in detecting known translational and rotational set-up errors and (2) transfer the transformation matrix of its registrations into a commercial treatment planning system (TPS) for offline organ motion analysis. Furthermore, CBCT dose index hasmore » been measured for a particular site (prostate: 120 kV, 1028.8 mAs, approximately 640 frames) using a standard Perspex cylindrical body phantom (diameter 32 cm, length 15 cm) and a 10-cm-long pencil ionization chamber. We have found that known displacements were correctly calculated by the registration software to within 1.3 mm and 0.4{sup o}. For the anthropomorphic phantom, only translational displacements have been considered. Both studies have shown errors within the intrinsic uncertainty of our system for translational displacements (estimated as 0.87 mm) and rotational displacements (estimated as 0.22{sup o}). The resulting table translations proposed by the system to correct the displacements were also checked with portal images and found to place the isocenter of the plan on the linac isocenter within an error of 1 mm, which is the dimension of the spherical lead marker inserted at the center of the homemade phantom. The registration matrix translated into the TPS image fusion module correctly reproduced the alignment between planning CT scans and CBCT scans. Finally, measurements on the CBCT dose index indicate that CBCT acquisition delivers less dose than conventional CT scans and electronic portal imaging device portals. The registration software was found to be accurate, and its registration matrix can be easily translated into the TPS and a low dose is delivered to the patient during image acquisition. These results can help in designing imaging protocols for offline evaluations.« less

  2. Calculation of Appropriate Minimum Size of Isolation Rooms based on Questionnaire Survey of Experts and Analysis on Conditions of Isolation Room Use

    NASA Astrophysics Data System (ADS)

    Won, An-Na; Song, Hae-Eun; Yang, Young-Kwon; Park, Jin-Chul; Hwang, Jung-Ha

    2017-07-01

    After the outbreak of the MERS (Middle East Respiratory Syndrome) epidemic, issues were raised regarding response capabilities of medical institutions, including the lack of isolation rooms at hospitals. Since then, the government of Korea has been revising regulations to enforce medical laws in order to expand the operation of isolation rooms and to strengthen standards regarding their mandatory installation at hospitals. Among general and tertiary hospitals in Korea, a total of 159 are estimated to be required to install isolation rooms to meet minimum standards. For the purpose of contributing to hospital construction plans in the future, this study conducted a questionnaire survey of experts and analysed the environment and devices necessary in isolation rooms, to determine their appropriate minimum size to treat patients. The result of the analysis is as follows: First, isolation rooms at hospitals are required to have a minimum 3,300mm minor axis and a minimum 5,000mm major axis for the isolation room itself, and a minimum 1,800mm minor axis for the antechamber where personal protective equipment is donned and removed. Second, the 15 ㎡-or-larger standard for the floor area of isolation rooms will have to be reviewed and standards for the minimum width of isolation rooms will have to be established.

  3. 72. SECOND FLOOR, HEATER ROOM ENTRANCE (UPPER RIGHT) AND STEEL, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    72. SECOND FLOOR, HEATER ROOM ENTRANCE (UPPER RIGHT) AND STEEL, CONCRETE, BRICK, AND SPRING AIR CONDITIONER BASE, BAY 31-32/4 SOUTH, TO WEST - Ford Motor Company Edgewater Assembly Plant, Assembly Building, 309 River Road, Edgewater, Bergen County, NJ

  4. 6. UNDERGROUND FIRING CONTROL ROOM, INTERIOR. Looking southeast to escape ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. UNDERGROUND FIRING CONTROL ROOM, INTERIOR. Looking southeast to escape tunnel. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA

  5. 5. PERSONNEL ROOM ON WEST SIDE OF PYROTECHNIC SHED (BLDG. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. PERSONNEL ROOM ON WEST SIDE OF PYROTECHNIC SHED (BLDG. 757) STORAGE LOCKER ON EAST WALL; PADDED TABLE ON SOUTH WALL. - Vandenberg Air Force Base, Space Launch Complex 3, Pyrotechnic Shed, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  6. 106. INTERIOR OF CABLE TRAY TUNNEL, FROM LANDLINE INSTRUMENTATION ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    106. INTERIOR OF CABLE TRAY TUNNEL, FROM LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770), TOWARDS CABLE TRAY SHED - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  7. VIEW OF SOUTH AND EAST SIDES OF FILTER ROOM/BATHHOUSE BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF SOUTH AND EAST SIDES OF FILTER ROOM/BATHHOUSE BUILDING S-196, FACING NORTHWEST. - U.S. Naval Base, Pearl Harbor, Outdoor Swimming Pool, Corner of Liscome Bay Street & St. Lo Avenue, Pearl City, Honolulu County, HI

  8. VIEW OF NORTH AND WEST SIDES OF FILTER ROOM/BATHHOUSE BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF NORTH AND WEST SIDES OF FILTER ROOM/BATHHOUSE BUILDING S-196, FACING SOUTHEAST. - U.S. Naval Base, Pearl Harbor, Outdoor Swimming Pool, Corner of Liscome Bay Street & St. Lo Avenue, Pearl City, Honolulu County, HI

  9. FACILITY 89. INTERIOR OF LIVING ROOM, TAKEN THROUGH BEVELED OPENING. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 89. INTERIOR OF LIVING ROOM, TAKEN THROUGH BEVELED OPENING. VIEW FACING NORTH. - U.S. Naval Base, Pearl Harbor, Naval Housing Area Makalapa, Junior Officers' Quarters Type K, Makin Place, & Halawa, Makalapa, & Midway Drives, Pearl City, Honolulu County, HI

  10. 11. Credit BG. Interior of control and observation room at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Credit BG. Interior of control and observation room at Control and Recording Center, showing detail of switchboard and closed circuit television monitors. - Jet Propulsion Laboratory Edwards Facility, Control & Recording Center, Edwards Air Force Base, Boron, Kern County, CA

  11. 13. EQUIPMENT USED IN CLEAN ROOM (102), INCLUDING ROYCO PARTICLE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. EQUIPMENT USED IN CLEAN ROOM (102), INCLUDING ROYCO PARTICLE COUNTER (LEFT) AND STEREOSCOPE FOR MANUAL PARTICLE COUNTING (RIGHT) - Vandenberg Air Force Base, Space Launch Complex 3, Vehicle Support Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  12. Developing an evidence base of best practices for integrating computerized systems into the exam room: a systematic review.

    PubMed

    Patel, Minal R; Vichich, Jennifer; Lang, Ian; Lin, Jessica; Zheng, Kai

    2017-04-01

    The introduction of health information technology systems, electronic health records in particular, is changing the nature of how clinicians interact with patients. Lack of knowledge remains on how best to integrate such systems in the exam room. The purpose of this systematic review was to (1) distill "best" behavioral and communication practices recommended in the literature for clinicians when interacting with patients in the presence of computerized systems during a clinical encounter, (2) weigh the evidence of each recommendation, and (3) rank evidence-based recommendations for electronic health record communication training initiatives for clinicians. We conducted a literature search of 6 databases, resulting in 52 articles included in the analysis. We extracted information such as study setting, research design, sample, findings, and implications. Recommendations were distilled based on consistent support for behavioral and communication practices across studies. Eight behavioral and communication practices received strong support of evidence in the literature and included specific aspects of using computerized systems to facilitate conversation and transparency in the exam room, such as spatial (re)organization of the exam room, maintaining nonverbal communication, and specific techniques that integrate the computerized system into the visit and engage the patient. Four practices, although patient-centered, have received insufficient evidence to date. We developed an evidence base of best practices for clinicians to maintain patient-centered communications in the presence of computerized systems in the exam room. Further work includes development and empirical evaluation of evidence-based guidelines to better integrate computerized systems into clinical care. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  13. Near-Threshold Fatigue Crack Growth Behavior of Fine-Grain Nickel-Based Alloys

    NASA Technical Reports Server (NTRS)

    Newman, John A.; Piascik, Robert S.

    2003-01-01

    Constant-Kmax fatigue crack growth tests were performed on two finegrain nickel-base alloys Inconel 718 (DA) and Ren 95 to determine if these alloys exhibit near-threshold time-dependent crack growth behavior observed for fine-grain aluminum alloys in room-temperature laboratory air. Test results showed that increases in K(sub max) values resulted in increased crack growth rates, but no evidence of time-dependent crack growth was observed for either nickel-base alloy at room temperature.

  14. Effects of Various Architectural Parameters on Six Room Acoustical Measures in Auditoria.

    NASA Astrophysics Data System (ADS)

    Chiang, Wei-Hwa

    The effects of architectural parameters on six room acoustical measures were investigated by means of correlation analyses, factor analyses and multiple regression analyses based on data taken in twenty halls. Architectural parameters were used to estimate acoustical measures taken at individual locations within each room as well as the averages and standard deviations of all measured values in the rooms. The six acoustical measures were Early Decay Time (EDT10), Clarity Index (C80), Overall Level (G), Bass Ratio based on Early Decay Time (BR(EDT)), Treble Ratio based on Early Decay Time (TR(EDT)), and Early Inter-aural Cross Correlation (IACC80). A comprehensive method of quantifying various architectural characteristics of rooms was developed to define a large number of architectural parameters that were hypothesized to effect the acoustical measurements made in the rooms. This study quantitatively confirmed many of the principles used in the design of concert halls and auditoria. Three groups of room architectural parameters such as the parameters associated with the depth of diffusing surfaces were significantly correlated with the hall standard deviations of most of the acoustical measures. Significant differences of statistical relations among architectural parameters and receiver specific acoustical measures were found between a group of music halls and a group of lecture halls. For example, architectural parameters such as the relative distance from the receiver to the overhead ceiling increased the percentage of the variance of acoustical measures that was explained by Barron's revised theory from approximately 70% to 80% only when data were taken in the group of music halls. This study revealed the major architectural parameters which have strong relations with individual acoustical measures forming the basis for a more quantitative method for advancing the theoretical design of concert halls and other auditoria. The results of this study provide designers the information to predict acoustical measures in buildings at very early stages of the design process without using computer models or scale models.

  15. Nicola Cusano e il foro astronomico al castello di Andraz

    NASA Astrophysics Data System (ADS)

    de Dona', G.

    Cardinal Nicolas from Cues (1401-1464) was friend of Paolo Toscanelli and one of the first supporters of heliocentrism. He carved a tube in the south western wall of a room of the castle of Andraz. It was possibly used to calculate the date of the winter solstice, in order to evaluate the corrections needed to the Julian calendar then in use. The astronomical use of this tube is described. The accuracy achievable in the measurement of the solstice is surprising. It is possible that the tubes made by Gerbert of Aurillac (945-1003) were used with similar awareness.

  16. Exploring proton transfer in 1,2,3-triazole-triazolium dimer with ab initio method

    NASA Astrophysics Data System (ADS)

    Li, Ailin; Yan, Tianying; Shen, Panwen

    Ab initio calculations are utilized to search for transition state structures for proton transfer in the 1,2,3-triazole-triazolium complexes on the basis of optimized dimers. The result suggests six transition state structures for single proton transfer in the complexes, most of which are coplanar. The energy barriers, between different stable and transition states structures with zero point energy (ZPE) corrections, show that proton transfer occurs at room temperature with coplanar configuration that has the lowest energy. The results clearly support that reorientation gives triazole flexibility for proton transfer.

  17. Determination of Patterson group symmetry from sparse multi-crystal data sets in the presence of an indexing ambiguity.

    PubMed

    Gildea, Richard J; Winter, Graeme

    2018-05-01

    Combining X-ray diffraction data from multiple samples requires determination of the symmetry and resolution of any indexing ambiguity. For the partial data sets typical of in situ room-temperature experiments, determination of the correct symmetry is often not straightforward. The potential for indexing ambiguity in polar space groups is also an issue, although methods to resolve this are available if the true symmetry is known. Here, a method is presented to simultaneously resolve the determination of the Patterson symmetry and the indexing ambiguity for partial data sets. open access.

  18. View of Mission Control Center during the Apollo 13 oxygen cell failure

    NASA Image and Video Library

    1970-04-14

    S70-34904 (14 April 1970) --- Astronaut Alan B. Shepard Jr., prime crew commander of the Apollo 14 mission, monitors communications between the Apollo 13 spacecraft and Mission Control Center. He is seated at a console in the Mission Operations Control Room of the MCC, Manned Spacecraft Center. The main concern of the moment was action taken by the three Apollo 13 crewmen - astronauts James A. Lovell Jr., John L. Swigert Jr. and Fred W. Haise Jr. - to make corrections inside the spacecraft following discovery of an oxygen cell failure several hours earlier.

  19. Magnetic Ordering in Sr 3YCo 4O 10+x

    DOE PAGES

    Kishida, Takayoshi; Kapetanakis, Myron D.; Yan, Jiaqiang; ...

    2016-01-28

    Transition-metal oxides often exhibit complex magnetic behavior due to the strong interplay between atomic-structure, electronic and magnetic degrees of freedom. Cobaltates, especially, exhibit complex behavior because of cobalt’s ability to adopt various valence and spin state configurations. The case of the oxygen-deficient perovskite Sr 3YCo 4O 10+x (SYCO) has gained considerable attention because of persisting uncertainties about its structure and the origin of the observed room temperature ferromagnetism. Here we report a combined investigation of SYCO using aberration-corrected scanning transmission electron microscopy and density functional theory calculations.

  20. 119. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (206), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    119. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (206), LSB (BLDG. 751). POWER DISTRIBUTION UNITS AND CABLE DISTRIBUTION UNITS ON RIGHT SIDE OF PHOTO; LOGIC CONTROL AND MONITOR UNITS FOR BOOSTER AND FUEL SYSTEMS LEFT OF AND PARALLEL TO EAST ROW OF CABINETS; SIGNAL CONDITIONERS AT NORTH END OF ROOM PERPENDICULAR TO OTHER CABINETS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. Extremely low frequency magnetic field measurements in buildings with transformer stations in Switzerland.

    PubMed

    Röösli, Martin; Jenni, Daniela; Kheifets, Leeka; Mezei, Gabor

    2011-08-15

    The aim of this study was to evaluate an exposure assessment method that classifies apartments in three exposure categories of extremely low frequency magnetic fields (ELF-MF) based on the location of the apartment relative to the transformer room. We completed measurements in 39 apartments in 18 buildings. In each room of the apartments ELF-MF was concurrently measured with 5 to 6 EMDEX II meters for 10 min. Measured arithmetic mean ELF-MF was 0.59 μT in 8 apartments that were fully adjacent to a transformer room, either directly above the transformer or touching the transformer room wall-to-wall. In apartments that only partly touched the transformer room at corners or edges, average ELF-MF level was 0.14 μT. Average exposure in the remaining apartments was 0.10 μT. Kappa coefficient for exposure classification was 0.64 (95%-CI: 0.45-0.82) if only fully adjacent apartments were considered as highly exposed (>0.4 μT). We found a distinct ELF-MF exposure gradient in buildings with transformer. Exposure classification based on the location of the apartment relative to the transformer room appears feasible. Such an approach considerably reduces effort for exposure assessment and may be used to eliminate selection bias in future epidemiologic studies. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. The robust corrective action priority-an improved approach for selecting competing corrective actions in FMEA based on principle of robust design

    NASA Astrophysics Data System (ADS)

    Sutrisno, Agung; Gunawan, Indra; Vanany, Iwan

    2017-11-01

    In spite of being integral part in risk - based quality improvement effort, studies improving quality of selection of corrective action priority using FMEA technique are still limited in literature. If any, none is considering robustness and risk in selecting competing improvement initiatives. This study proposed a theoretical model to select risk - based competing corrective action by considering robustness and risk of competing corrective actions. We incorporated the principle of robust design in counting the preference score among corrective action candidates. Along with considering cost and benefit of competing corrective actions, we also incorporate the risk and robustness of corrective actions. An example is provided to represent the applicability of the proposed model.

  3. Room temperature, air crystallized perovskite film for high performance solar cells

    DOE PAGES

    Dubey, Ashish; Kantack, Nicholas; Adhikari, Nirmal; ...

    2016-05-31

    For the first time, room temperature heating free growth and crystallization of perovskite films in ambient air without the use of thermal annealing is reported. Highly efficient perovskite nanorod-based solar cells were made using ITO/PEDOT:PSS/CH 3NH 3PbI 3 nanorods/PC 60BM/rhodamine/Ag. All the layers except PEDOT:PSS were processed at room temperature thereby eliminating the need for thermal treatment. Perovskite films were spin coated inside a N-2 filled glovebox and immediately were taken outside in air having 40% relative humidity (RH). Exposure to humid air was observed to promote the crystallization process in perovskite films even at room temperature. Perovskite films keptmore » for 5 hours in ambient air showed nanorod-like morphology having high crystallinity, with devices exhibiting the highest PCE of 16.83%, which is much higher than the PCE of 11.94% for traditional thermally annealed perovskite film based devices. Finally, it was concluded that moisture plays an important role in room temperature crystallization of pure perovskite nanorods, showing improved optical and charge transport properties, which resulted in high performance solar cells.« less

  4. Wiring repair area, southwest corner of room 227, looking east. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Wiring repair area, southwest corner of room 227, looking east. Repair area includes soldering equipment and wire dispensing reels hanging from the ceiling - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  5. A Randomized Prospective Study Of The Use Of Ipads In Reducing Anxiety During Cast Room Procedures

    PubMed Central

    Ko, Justine S.; Whiting, Zachariah; Nguyen, Cynthia; Liu, Raymond W; Gilmore, Allison

    2016-01-01

    Background Cast room procedures can be a source of anxiety for children. Various techniques, including music therapy, have been evaluated as a way to ease this anxiety. The use of iPads as a form of distraction during cast room procedures has not previously been evaluated and was the purpose of the current study. Methods 146 children and adolescents who underwent cast room procedures during June- August 2015 were randomly assigned to one of three groups: no-iPad, iPad with video, or iPad with game. Patient heart rates were measured using a pulse oximeter in the waiting room, before the procedure, during the procedure, and after the procedure. Mean values for each group were calculated at each time interval and compared both between groups and within groups over time. Results There were no significant differences in baseline (waiting room) heart rate between the no-iPad and iPad groups. When compared with the no-iPad group, there was a trend toward decreased heart rate in the video group (p=0.13) and a significant increase in heart rate in the game group (p=0.026) before the procedure. There were no significant decreases in heart rate within any of the groups when comparing the waiting room heart rates with the during procedure heart rates. There was a significant difference between the no-iPad and video groups (p=0.047) when comparing the change in heart rate from baseline to before the procedure, with a decreased heart rate observed in the video group. Conclusions The results of this study show a significant decrease in heart rate when transitioning from the waiting room to the cast room while watching videos on the iPad. iPad-based video delivery appears to decrease anxiety prior to cast room procedures. iPad-based game play is difficult to assess as elevations in heart rate prior to the procedure are presumed to be related to game play and confound the observed effect it may have on anxiety related to the procedure. PMID:27528849

  6. A simulator-based nuclear reactor emergency response training exercise.

    PubMed

    Waller, Edward; Bereznai, George; Shaw, John; Chaput, Joseph; Lafortune, Jean-Francois

    Training offsite emergency response personnel basic awareness of onsite control room operations during nuclear power plant emergency conditions was the primary objective of a week-long workshop conducted on a CANDU® virtual nuclear reactor simulator available at the University of Ontario Institute of Technology, Oshawa, Canada. The workshop was designed to examine both normal and abnormal reactor operating conditions, and to observe the conditions in the control room that may have impact on the subsequent offsite emergency response. The workshop was attended by participants from a number of countries encompassing diverse job functions related to nuclear emergency response. Objectives of the workshop were to provide opportunities for participants to act in the roles of control room personnel under different reactor operating scenarios, providing a unique experience for participants to interact with the simulator in real-time, and providing increased awareness of control room operations during accident conditions. The ability to "pause" the simulator during exercises allowed the instructors to evaluate and critique the performance of participants, and to provide context with respect to potential offsite emergency actions. Feedback from the participants highlighted (i) advantages of observing and participating "hands-on" with operational exercises, (ii) their general unfamiliarity with control room operational procedures and arrangements prior to the workshop, (iii) awareness of the vast quantity of detailed control room procedures for both normal and transient conditions, and (iv) appreciation of the increased workload for the operators in the control room during a transient from normal operations. Based upon participant feedback, it was determined that the objectives of the training had been met, and that future workshops should be conducted.

  7. Effect of high moisture storage of pearl millet (Pennisetum typhoides) with or without feed enzymes on growth and nutrient utilization in broiler chickens.

    PubMed

    Manwar, Satish Jagannath; Mandal, Asit Baran

    2009-08-01

    Effect of reconstitution of pearl millet with or without enzymes on its utilization in broiler chickens was studied. The pearl millet grains were reconstituted by adding water to raise the moisture level to 30%, followed by storage in sealed plastic buckets with or without feed enzymes (0.5 g/kg) for 21 days at room temperature (25 degrees C). Subsequently, the grains were sun-dried to reduce the moisture content up to 10% to avoid mould growth. Nine dietary treatments were formulated incorporating pearl millet either raw with or without enzymes or reconstituted with or without enzymes in maize-soya based control diet replacing maize at 50 and 75% levels. The birds fed on diets containing enzyme reconstituted pearl millet accrued higher body weight than maize based control diet. Addition of enzymes to raw pearl-millet based diet improved the body weight gain significantly. The reconstitution of pearl millet with or without enzymes increased (P < 0.01) the dietary nitrogen corrected apparent metabolizable energy (AMEn) values and the highest improvement (6.11%) was recorded in diets containing pearl millet reconstituted with enzymes at 75% level of maize replacement. The percent nitrogen retention in pearl millet based diets was comparable to maize based control diet. It may be concluded that the supplementation of the feed enzymes or reconstitution of pearl millet may improve the utilization of pearl millet in broiler chickens.

  8. Operating room efficiency improvement after implementation of a postoperative team assessment.

    PubMed

    Porta, Christopher R; Foster, Andrew; Causey, Marlin W; Cordier, Patricia; Ozbirn, Roger; Bolt, Stephen; Allison, Dennis; Rush, Robert

    2013-03-01

    Operating room time is highly resource intensive, and delays can be a source of lost revenue and surgeon frustration. Methods to decrease these delays are important not only for patient care, but to maximize operating room resource utilization. The purpose of this study was to determine the root cause of operating room delays in a standardized manner to help improve overall operating room efficiency. We performed a single-center prospective observational study analyzing operating room utilization and efficiency after implementing an executive-driven standardized postoperative team debriefing system from January 2010 to December 2010. A total of 11,342 procedures were performed over the 1-y study period (elective 86%, urgent 11%, and emergent 3%), with 1.3 million min of operating room time, 865,864 min of surgeon operative time (62.5%), and 162,958 min of anesthesia time (11.8%). Overall, the average operating room delay was 18 min and varied greatly based on the surgical specialty. The longest delays were due to need for radiology (40 min); other significant delays were due to supply issues (22.7 min), surgeon issues (18 min), nursing issues (14 min), and room turnover (14 min). Over the 1-y period, there was a decrease in mean delay duration, averaging a decrease in delay of 0.147 min/mo with an overall 9% decrease in the mean delay times. With regard to overall operating room utilization, there was a 39% decrease in overall un-utilized available OR time that was due to delays, improving efficiency by 2334 min (212 min/mo). During this study interval no sentinel events occurred in the operating room. A standardized postoperative debrief tracking system is highly beneficial in identifying and reducing overall operative delays and improving operating room utilization. Published by Elsevier Inc.

  9. Influence of low ambient temperature on epitympanic temperature measurement: a prospective randomized clinical study.

    PubMed

    Strapazzon, Giacomo; Procter, Emily; Putzer, Gabriel; Avancini, Giovanni; Dal Cappello, Tomas; Überbacher, Norbert; Hofer, Georg; Rainer, Bernhard; Rammlmair, Georg; Brugger, Hermann

    2015-11-05

    Epitympanic temperature (Tty) measured with thermistor probes correlates with core body temperature (Tcore), but the reliability of measurements at low ambient temperature is unknown. The aim of this study was to determine if commercially-available thermistor-based Tty reflects Tcore in low ambient temperature and if Tty is influenced by insulation of the ear. Thirty-one participants (two females) were exposed to room (23.2 ± 0.4 °C) and low (-18.7 ± 1.0 °C) ambient temperature for 10 min using a randomized cross-over design. Tty was measured using an epitympanic probe (M1024233, GE Healthcare Finland Oy) and oesophageal temperature (Tes) with an oesophageal probe (M1024229, GE Healthcare Finland Oy) inserted into the lower third of the oesophagus. Ten participants wore ear protectors (Arton 2200, Emil Lux GmbH & Co. KG, Wermelskirchen, Switzerland) to insulate the ear from ambient air. During exposure to room temperature, mean Tty increased from 33.4 ± 1.5 to 34.2 ± 0.8 °C without insulation of the ear and from 35.0 ± 0.8 to 35.5 ± 0.7 °C with insulation. During exposure to low ambient temperature, mean Tty decreased from 32.4 ± 1.6 to 28.5 ± 2.0 °C without insulation and from 35.6 ± 0.6 to 35.2 ± 0.9 °C with insulation. The difference between Tty and Tes at low ambient temperature was reduced by 82% (from 7.2 to 1.3 °C) with insulation of the ear. Epitympanic temperature measurements are influenced by ambient temperature and deviate from Tes at room and low ambient temperature. Insulating the ear with ear protectors markedly reduced the difference between Tty and Tes and improved the stability of measurements. The use of models to correct Tty may be possible, but results should be validated in larger studies.

  10. Technical Note: Mobile accelerator guidance using an optical tracker during docking in IOERT procedures.

    PubMed

    Marinetto, Eugenio; Victores, Juan González; García-Sevilla, Mónica; Muñoz, Mercedes; Calvo, Felipe Ángel; Balaguer, Carlos; Desco, Manuel; Pascau, Javier

    2017-10-01

    Intraoperative electron radiation therapy (IOERT) involves the delivery of a high radiation dose during tumor resection in a shorter time than other radiation techniques, thus improving local control of tumors. However, a linear accelerator device is needed to produce the beam safely. Mobile linear accelerators have been designed as dedicated units that can be moved into the operating room and deliver radiation in situ. Correct and safe dose delivery is a key concern when using mobile accelerators. The applicator is commonly fixed to the patient's bed to ensure that the dose is delivered to the prescribed location, and the mobile accelerator is moved to dock the applicator to the radiation beam output (gantry). In a typical clinical set-up, this task is time-consuming because of safety requirements and the limited degree of freedom of the gantry. The objective of this study was to present a navigation solution based on optical tracking for guidance of docking to improve safety and reduce procedure time. We used an optical tracker attached to the mobile linear accelerator to track the prescribed localization of the radiation collimator inside the operating room. Using this information, the integrated navigation system developed computes the movements that the mobile linear accelerator needs to perform to align the applicator and the radiation gantry and warns the physician if docking is unrealizable according to the available degrees of freedom of the mobile linear accelerator. Furthermore, we coded a software application that connects all the necessary functioning elements and provides a user interface for the system calibration and the docking guidance. The system could safeguard against the spatial limitations of the operating room, calculate the optimal arrangement of the accelerator and reduce the docking time in computer simulations and experimental setups. The system could be used to guide docking with any commercial linear accelerator. We believe that the docking navigator we present is a major contribution to IOERT, where docking is critical when attempting to reduce surgical time, ensure patient safety and guarantee that the treatment administered follows the radiation oncologist's prescription. © 2017 American Association of Physicists in Medicine.

  11. Impact of Hospital-Employed Physician Assistants on a Level II Community-Based Orthopaedic Trauma System.

    PubMed

    Althausen, Peter L; Shannon, Steven; Owens, Brianne; Coll, Daniel; Cvitash, Michael; Lu, Minggen; O'Mara, Timothy J; Bray, Timothy J

    2016-12-01

    The American Academy of Orthopedic Surgeons and the Orthopedic Trauma Association have released guidelines for the provision of orthopedic trauma services such as adequate stipends, designated operating rooms, ancillary staff, and guaranteed reimbursement for indigent care. One recommendation included a provision for hospital-based physician assistants (PAs). Given current reimbursement arrangements, PA collections for billable services may not meet their salary and benefit expenses. However, their actions may indirectly affect emergency room, operating room, and hospital reimbursement and patient care itself. The purpose of our study is to define the true impact of hospitalbased PAs on orthopaedic trauma care at a level II community hospital. Retrospective case series. Level II trauma center. One thousand one hundred four trauma patients with orthopaedic injuries. PA involvement. Emergency room data such as triage time, time until seen by the orthopedic service, and total emergency room time was recorded. Operating room data such as time to surgery, set-up time, total operating time, and out of room time was entered as well. Charts were reviewed to determine if patients were given postoperative antibiotics and Deep Venous Thrombosis (DVT) prophylaxis. Intraoperative and postoperative complications were noted, and lengths of stay were calculated for all patients. At our institution, PA collections from patient care cover only 50% of their costs for salary and benefits. However, with PA involvement, trauma patients with orthopedic injuries were seen 205 minutes faster (P = 0.006), total Emergency Room (ER) time decreased 175 minutes (P = 0.0001), and time to surgery improved 360 minutes (P . 0.03). Operating room parameters were minimally improved, but postoperative DVT prophylaxis increased by a mean of 6.73% (P = 0.0084), postoperative antibiotic administration increased by 2.88% (P = 0.0302), and there was a 4.67% decrease in postoperative complications (P = 0.0034). Average length of stay decreased by 0.61 days (P = 0.27). Although the PA's collections do not cover their costs, the indirect economic and patient care impacts are clear. By increasing emergency room pull through and decreasing times to Operating Room (OR), operative times, lengths of stay, and complications, their existence is clearly beneficial to hospitals, physicians, and patients as well. Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  12. Oblique of recreation center portion, showing onestory exercise room with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Oblique of recreation center portion, showing one-story exercise room with louvered windows and two-story section as left. - U.S. Naval Base, Pearl Harbor, Bloch Recreation Center & Arena, Between Center Drive & North Road near Nimitz Gate, Pearl City, Honolulu County, HI

  13. Room-Temperature Ionic Liquids for Electrochemical Capacitors

    NASA Technical Reports Server (NTRS)

    Fireman, Heather; Yowell, Leonard; Moloney, Padraig G.; Arepalli, Sivaram; Nikolaev, P.; Huffman, C.; Ready, Jud; Higgins, C.D.; Turano, S. P.; Kohl, P.A.; hide

    2009-01-01

    A document discusses room-temperature ionic liquids (RTILs) used as electrolytes in carbon-nanotube-based, electrochemical, double-layer capacitors. Unlike the previous electrolyte (EtNB4 in acetonitrile), the RTIL used here does not produce cyanide upon thermal decomposition and does not have a moisture sensitivity.

  14. Interior, equipment room, weather support area (from July, 1968 drawing) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior, equipment room, weather support area (from July, 1968 drawing) at north end of display area, looking west. Window looks south towards the main console - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  15. 3. SHOP AREA. Looking west into storage cage from near ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. SHOP AREA. Looking west into storage cage from near northeast corner of room. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  16. 26. VIEW OF PUMP ROOM, SHOWING PORTIONS OF HIGH PRESSURE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. VIEW OF PUMP ROOM, SHOWING PORTIONS OF HIGH PRESSURE AIR SYSTEM AT LEFT AND CENTER AND OVERFLOW STORAGE TANK AT RIGHT, LOOKING NORTHWEST - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  17. 49. Environmental equipment room, cbr filter at left, ventilation control ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    49. Environmental equipment room, cbr filter at left, ventilation control panel in center, brine chiller controls at right, looking southeast - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  18. 22. INTERIOR VIEW, BASEMENT UNDER NORTH ROOM OF MAIN BLOCK, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. INTERIOR VIEW, BASEMENT UNDER NORTH ROOM OF MAIN BLOCK, VIEW OF NORTHWEST WALL SHOWING CORBELING BASE OF FIRST FLOOR CHIMNEY BLOCK WITH STOVE-PIPE HOLE, AND MORTISE AND TENON FRAMING FOR HEARTH BED - Clifton Farm, Off Baker Road, Frederick, Frederick County, MD

  19. Room temperature continuous wave, monolithic tunable THz sources based on highly efficient mid-infrared quantum cascade lasers

    PubMed Central

    Lu, Quanyong; Wu, Donghai; Sengupta, Saumya; Slivken, Steven; Razeghi, Manijeh

    2016-01-01

    A compact, high power, room temperature continuous wave terahertz source emitting in a wide frequency range (ν ~ 1–5 THz) is of great importance to terahertz system development for applications in spectroscopy, communication, sensing, and imaging. Here, we present a strong-coupled strain-balanced quantum cascade laser design for efficient THz generation based on intracavity difference frequency generation. Room temperature continuous wave emission at 3.41 THz with a side-mode suppression ratio of 30 dB and output power up to 14 μW is achieved with a wall-plug efficiency about one order of magnitude higher than previous demonstrations. With this highly efficient design, continuous wave, single mode THz emissions with a wide frequency tuning range of 2.06–4.35 THz and an output power up to 4.2 μW are demonstrated at room temperature from two monolithic three-section sampled grating distributed feedback-distributed Bragg reflector lasers. PMID:27009375

  20. Room temperature continuous wave, monolithic tunable THz sources based on highly efficient mid-infrared quantum cascade lasers.

    PubMed

    Lu, Quanyong; Wu, Donghai; Sengupta, Saumya; Slivken, Steven; Razeghi, Manijeh

    2016-03-24

    A compact, high power, room temperature continuous wave terahertz source emitting in a wide frequency range (ν~1-5 THz) is of great importance to terahertz system development for applications in spectroscopy, communication, sensing, and imaging. Here, we present a strong-coupled strain-balanced quantum cascade laser design for efficient THz generation based on intracavity difference frequency generation. Room temperature continuous wave emission at 3.41 THz with a side-mode suppression ratio of 30 dB and output power up to 14 μW is achieved with a wall-plug efficiency about one order of magnitude higher than previous demonstrations. With this highly efficient design, continuous wave, single mode THz emissions with a wide frequency tuning range of 2.06-4.35 THz and an output power up to 4.2 μW are demonstrated at room temperature from two monolithic three-section sampled grating distributed feedback-distributed Bragg reflector lasers.

  1. [Status of measures against angiography room infection as determined by questionnaire].

    PubMed

    Tsukamoto, Atsuko; Ito, Makiko; Takahashi, Kanji; Watanabe, Emi; Kikuchi, Tatsuya; Tajima, Osamu; Masuda, Kazuhiro; Wakamatsu, Osamu; Sato, Tsugio; Nakazawa, Yasuo

    2006-11-20

    Although the cleanliness of the angiography room and that of the operating room have long been equally attended to, the concept of Standard Precautions (including the basic measures and procedures to prevent infection) of the Centers for Disease Control and Prevention (CDC), 1996, as well as the introduction of transmission-based precautions, have been changing to preventive measures that are based on concrete measures. Therefore, a questionnaire was introduced in order to determine the actual status of countermeasures against infection used in the angiography room. The questionnaire was sent to 530 institutions, and 286 responded, a response rate of 54.0%. Its results significantly revealed the following: 1) unexpectedly low recognition of the need and importance for the CDC preventive measures against infection, 2) a considerable number of institutions continuing to perform the conventional preventive measures, 3) problems with education systems on preventive measures, and 4) handwashing, the most important measure against infection, failing to be adequately carried out noticeably among radiological technologists.

  2. Study of a dry room in a battery manufacturing plant using a process model

    NASA Astrophysics Data System (ADS)

    Ahmed, Shabbir; Nelson, Paul A.; Dees, Dennis W.

    2016-09-01

    The manufacture of lithium ion batteries requires some processing steps to be carried out in a dry room, where the moisture content should remain below 100 parts per million. The design and operation of such a dry room adds to the cost of the battery. This paper studied the humidity management of the air to and from the dry room to understand the impact of design and operating parameters on the energy demand and the cost contribution towards the battery manufacturing cost. The study was conducted with the help of a process model for a dry room with a volume of 16,000 cubic meters. For a defined base case scenario it was found that the dry room operation has an energy demand of approximately 400 kW. The paper explores some tradeoffs in design and operating parameters by looking at the humidity reduction by quenching the make-up air vs. at the desiccant wheel, and the impact of the heat recovery from the desiccant regeneration cycle.

  3. Evaluation of wind-induced internal pressure in low-rise buildings: A multi scale experimental and numerical approach

    NASA Astrophysics Data System (ADS)

    Tecle, Amanuel Sebhatu

    Hurricane is one of the most destructive and costly natural hazard to the built environment and its impact on low-rise buildings, particularity, is beyond acceptable. The major objective of this research was to perform a parametric evaluation of internal pressure (IP) for wind-resistant design of low-rise buildings and wind-driven natural ventilation applications. For this purpose, a multi-scale experimental, i.e. full-scale at Wall of Wind (WoW) and small-scale at Boundary Layer Wind Tunnel (BLWT), and a Computational Fluid Dynamics (CFD) approach was adopted. This provided new capability to assess wind pressures realistically on internal volumes ranging from small spaces formed between roof tiles and its deck to attic to room partitions. Effects of sudden breaching, existing dominant openings on building envelopes as well as compartmentalization of building interior on the IP were systematically investigated. Results of this research indicated: (i) for sudden breaching of dominant openings, the transient overshooting response was lower than the subsequent steady state peak IP and internal volume correction for low-wind-speed testing facilities was necessary. For example a building without volume correction experienced a response four times faster and exhibited 30--40% lower mean and peak IP; (ii) for existing openings, vent openings uniformly distributed along the roof alleviated, whereas one sided openings aggravated the IP; (iii) larger dominant openings exhibited a higher IP on the building envelope, and an off-center opening on the wall exhibited (30--40%) higher IP than center located openings; (iv) compartmentalization amplified the intensity of IP and; (v) significant underneath pressure was measured for field tiles, warranting its consideration during net pressure evaluations. The study aimed at wind driven natural ventilation indicated: (i) the IP due to cross ventilation was 1.5 to 2.5 times higher for Ainlet/Aoutlet>1 compared to cases where Ainlet/Aoutlet<1, this in effect reduced the mixing of air inside the building and hence the ventilation effectiveness; (ii) the presence of multi-room partitioning increased the pressure differential and consequently the air exchange rate. Overall good agreement was found between the observed large-scale, small-scale and CFD based IP responses. Comparisons with ASCE 7-10 consistently demonstrated that the code underestimated peak positive and suction IP.

  4. Patient visibility and ICU mortality: a conceptual replication.

    PubMed

    Lu, Yi; Ossmann, Michelle M; Leaf, David E; Factor, Philip H

    2014-01-01

    This study reanalyzes the data from a study by Leaf, Homel, and Factor (2010) titled "Relationship between ICU Design and Mortality" by adopting and developing objective visibility measures. Various studies attribute healthcare outcomes (patient falls, satisfaction) to a vague notion of patient room visibility. The study by Leaf and colleagues was the first to draw an independent association between patient mortality and patient room visibility, however "visibility" remains imprecise. The original patient dataset was obtained from Dr. Leaf. The 664 patient sample assigned across 12 rooms at the medical ICU at Columbia University Medical Center was reanalyzed in terms of targeted visibility; the unit of analysis was the room, n = 12. Several computer-based visibility measures of patient rooms were used: patient head visibility, patient room visibility, and field of view to nursing station. Patient head visibility was defined as the percentage of area within the central nursing station from which the patient head could be seen; patient room visibility was defined as the percentage of area within the central nursing station that could see the patient room (average value of all patient room grids); field of view was defined as the maximum viewing angle from the patient head to the central nursing station. Among the sickest patients (those with Acute Physiology and Chronic Health Evaluation II > 30), field of view accounted for 33.5% of the variance in ICU mortality, p = 0.049. Subtle differences in patient room visibility may have important effects on clinical outcomes. Case study, critical care/intensive care, methodology, outcomes.

  5. 98. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (106), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    98. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770). POWER DISTRIBUTION UNITS AND CABLE DISTRIBUTION UNITS IN EAST ROW OF CABINETS; LOGIC CONTROL AND MONITOR UNITS FOR BOOSTER AND FUEL SYSTEMS, AND SIGNAL CONDITIONERS IN WEST ROW OF CABINETS. CABLE TRAY TUNNEL ENTRANCE TO LSB (BLDG. 770) AT THE SOUTH END OF LANDLINE INSTRUMENTATION ROOM (106). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  6. A public health model of Medicaid emergency room use.

    PubMed

    de Alteriis, M; Fanning, T

    1991-01-01

    This study builds a public health model of Medicaid emergency room use for 57 upstate counties in New York from 1985 to 1987. The principle explanatory variables are primary care use (based in physicians' offices, freestanding clinics, and hospital outpatient departments), the concentration of poverty, and geographic and hospital availability. These factors influence the emergency room use of all Medicaid aid categories apart from the Supplemental Security Income recipients. Inherent in these findings are a number of policy implications that are explored in this article.

  7. Continued development of thallium bromide and related compounds for gamma-ray spectrometers

    NASA Astrophysics Data System (ADS)

    Kim, H.; Churilov, A.; Ciampi, G.; Cirignano, L.; Higgins, W.; Kim, S.; O'Dougherty, P.; Olschner, F.; Shah, Kanai

    2011-02-01

    Thallium bromide (TlBr) and related ternary compounds, TlBrI and TlBrCl, have been under development for room temperature gamma-ray spectroscopy due to high density, high Z and wide bandgap of the material. Low melting point and cubic crystal structure of selected compositions of these compounds facilitate crystal growth by melt techniques. Recent advances in material purification, crystal growth, and device processing have led to mobility-lifetime products of electrons in the mid 10 -3 cm 2/V range enabling working detectors of greater than 15 mm thickness to be fabricated. In this paper we report on our recent progress on TlBr detector development and first results from TlBr xCl 1- x devices. Pulse height spectra will be presented from TlBr arrays as thick as 18 mm. Depth corrected spectra will also be presented. For a 5 mm thick TlBr array, energy resolution of less than 1% (FWHM at 662 keV) was obtained after depth correction.

  8. How Children with Autism Reason about Other's Intentions: False-Belief and Counterfactual Inferences.

    PubMed

    Rasga, Célia; Quelhas, Ana Cristina; Byrne, Ruth M J

    2017-06-01

    We examine false belief and counterfactual reasoning in children with autism with a new change-of-intentions task. Children listened to stories, for example, Anne is picking up toys and John hears her say she wants to find her ball. John goes away and the reason for Anne's action changes-Anne's mother tells her to tidy her bedroom. We asked, 'What will John believe is the reason that Anne is picking up toys?' which requires a false-belief inference, and 'If Anne's mother hadn't asked Anne to tidy her room, what would have been the reason she was picking up toys?' which requires a counterfactual inference. We tested children aged 6, 8 and 10 years. Children with autism made fewer correct inferences than typically developing children at 8 years, but by 10 years there was no difference. Children with autism made fewer correct false-belief than counterfactual inferences, just like typically developing children.

  9. Beyond-proximity-force-approximation Casimir force between two spheres at finite temperature

    NASA Astrophysics Data System (ADS)

    Bimonte, Giuseppe

    2018-04-01

    A recent experiment [J. L. Garrett, D. A. T. Somers, and J. N. Munday, Phys. Rev. Lett. 120, 040401 (2018), 10.1103/PhysRevLett.120.040401] measured for the first time the gradient of the Casimir force between two gold spheres at room temperature. The theoretical analysis of the data was carried out using the standard proximity force approximation (PFA). A fit of the data, using a parametrization of the force valid for the sphere-plate geometry, was used by the authors to place a bound on deviations from PFA. Motivated by this work, we compute the Casimir force between two gold spheres at finite temperature. The semianalytic formula for the Casimir force that we construct is valid for all separations, and can be easily used to interpret future experiments in both the sphere-plate and sphere-sphere configurations. We describe the correct parametrization of the corrections to PFA for two spheres that should be used in data analysis.

  10. Examining the Impact of Patient Characteristics and Symptomatology on Knowledge, Attitudes, and Beliefs Among Foreign-born Tuberculosis Cases in the US and Canada

    PubMed Central

    Couzens, G. Lance; Royce, Rachel A.; Kline, Tracy; Chavez-Lindell, Tamara; Welbel, Sharon; Pang, Jenny; Davidow, Amy; Hirsch-Moverman, Yael

    2016-01-01

    Foreign-born individuals represent the majority of TB cases in the US/Canada. Little is known about their TB knowledge, attitudes, and beliefs (KAB). Cross-sectional survey was conducted in 22 sites in the US/Canada among foreign-born adults with active TB. Multiple regression was used to examine KAB factors against covariates. Of 1,475 participants interviewed, most answered the six knowledge items correctly. Significant predictors of correct knowledge included region of origin, education, income, age, visa status, place of diagnosis, BCG vaccination, and TB symptoms. Significant predictors of higher perceived risk/stigma scores included region of origin, age, place of diagnosis, English fluency, time in the US/Canada, TB symptoms, and household rooms. This study examines associations between TB KAB and patient and disease characteristics in foreign-born individuals in the US/Canada. The findings call for improved health education, along with efforts to reduce stigma and enhance realistic risk assessments. PMID:23440450

  11. Examining the impact of patient characteristics and symptomatology on knowledge, attitudes, and beliefs among foreign-born tuberculosis cases in the US and Canada.

    PubMed

    Colson, Paul W; Couzens, G Lance; Royce, Rachel A; Kline, Tracy; Chavez-Lindell, Tamara; Welbel, Sharon; Pang, Jenny; Davidow, Amy; Hirsch-Moverman, Yael

    2014-02-01

    Foreign-born individuals represent the majority of TB cases in the US/Canada. Little is known about their TB knowledge, attitudes, and beliefs (KAB). Cross-sectional survey was conducted in 22 sites in the US/Canada among foreign-born adults with active TB. Multiple regression was used to examine KAB factors against covariates. Of 1,475 participants interviewed, most answered the six knowledge items correctly. Significant predictors of correct knowledge included region of origin, education, income, age, visa status, place of diagnosis, BCG vaccination, and TB symptoms. Significant predictors of higher perceived risk/stigma scores included region of origin, age, place of diagnosis, English fluency, time in the US/Canada, TB symptoms, and household rooms. This study examines associations between TB KAB and patient and disease characteristics in foreign-born individuals in the US/Canada. The findings call for improved health education, along with efforts to reduce stigma and enhance realistic risk assessments.

  12. Prospective object search in dogs: mixed evidence for knowledge of What and Where.

    PubMed

    Kaminski, Juliane; Fischer, Julia; Call, Josep

    2008-04-01

    We investigated whether two dogs that had been specially trained to retrieve objects by their names were able to integrate information about the identity (What) as well as the location (Where) of those objects so that they could plan their search accordingly. In a first study, two sets of objects were placed in two separate rooms and subjects were asked to retrieve the objects, one after the other. Both dogs remembered the identity of the objects as they reliably retrieved the correct objects. One of the dogs was also able to integrate information about the object's location as he chose the correct location in which the object had been placed. Further investigation of the second dog's behavior revealed that she followed a more stereotyped search strategy. Despite this variation in performance, this study provides evidence for the memory of What and Where in a domestic dog and shows the prospective use of such information in a search task.

  13. Pig Organ Energy Loss Comparison Experiments Using BBs.

    PubMed

    Maiden, Nicholas R; Musgrave, Ian; Fisk, Wesley; Byard, Roger W

    2016-05-01

    Torso models for ballistics research require that the mechanical properties of simulant materials must match the heterogeneous nature of tissues/organs within the human thorax/abdomen. A series of energy loss experiments were conducted on fresh porcine organs/tissues at room temperature and 37°C, using steel 4.5 mm BBs fired from a Daisy(®) brand air rifle. They were compared to FBI and NATO specification ordnance gelatin and a candidate surrogate material called Simulant "A". Two CED M2 chronographs measured BB velocity. The resulting energy loss was established using KE = 1/2 mv² before and after target perforation. The combined results at room temperature and 37°C were as follows: FBI specification gelatin was similar (p > 0.05) to heart and lung, spleen was similar to NATO specification gelatin, Simulant "A" was similar to hindquarter muscle, and hindquarter muscle, kidney, and spleen were similar to each other regarding energy retardation. These results can be used as a basis for the development of simulant materials to create an anatomically correct heterogeneous model. © 2016 American Academy of Forensic Sciences.

  14. Gestonurse: a robotic surgical nurse for handling surgical instruments in the operating room.

    PubMed

    Jacob, Mithun; Li, Yu-Ting; Akingba, George; Wachs, Juan P

    2012-03-01

    While surgeon-scrub nurse collaboration provides a fast, straightforward and inexpensive method of delivering surgical instruments to the surgeon, it often results in "mistakes" (e.g. missing information, ambiguity of instructions and delays). It has been shown that these errors can have a negative impact on the outcome of the surgery. These errors could potentially be reduced or eliminated by introducing robotics into the operating room. Gesture control is a natural and fundamentally sound alternative that allows interaction without disturbing the normal flow of surgery. This paper describes the development of a robotic scrub nurse Gestonurse to support surgeons by passing surgical instruments during surgery as required. The robot responds to recognized hand signals detected through sophisticated computer vision and pattern recognition techniques. Experimental results show that 95% of the gestures were recognized correctly. The gesture recognition algorithm presented is robust to changes in scale and rotation of the hand gestures. The system was compared to human task performance and was found to be only 0.83 s slower on average.

  15. [The operating room of the future].

    PubMed

    Broeders, I A; Niessen, W; van der Werken, C; van Vroonhoven, T J

    2000-01-29

    Advances in computer technology will revolutionize surgical techniques in the next decade. The operating room (OR) of the future will be connected with a laboratory where clinical specialists and researchers prepare image-guided interventions and explore the possibilities of these techniques. The virtual reality is linked to the actual situation in the OR with the aid of navigation instruments. During complicated operations the images prepared preoperatively will be corrected during the operation on the basis of the information obtained peroperatively. MRI currently offers maximal possibilities for image-guided surgery of soft tissues. Simpler techniques such as fluoroscopy and echography will become increasingly integrated in computer-assisted peroperative navigation. The development of medical robot systems will make possible microsurgical procedures by the endoscopic route. Tele-manipulation systems will also play a part in the training of surgeons. Design and construction of the OR will be adapted to the surgical technology, and include an information and control unit where preoperative and peroperative data come together and from where the surgeon operates the instruments. Concepts for the future OR should be regularly adjusted to allow for new surgical technology.

  16. Modification de l'état d'ordre local d'alliages austénitiques Fe-Cr-Ni au cours de la déformation plastique par traction

    NASA Astrophysics Data System (ADS)

    Aïdi, B.; Bertrand, C.; Viltange, M.; Dimitrov, O.

    1993-09-01

    The influence of plastic deformation, by extension at room temperature, on electrical resistivity has been determined in four austenitic Fe-Cr-Ni alloys with 16 wt% Cr and 20, 25, 45 or 75 wt% Ni, in two different states of local order. Two experimental methods have been used (4.2 K resistance measurements before and after deformation, continuous resistance measurements during room-temperature extension tests); the possibilities of the second method and the corrections to be applied are particularly discussed. Resistivity is found to slightly increase at the beginning of deformation ( e < 0.05), then to strongly decrease. The amplitude of the observed effects increases with the nickel content, and with the initial degree of local order. In the high deformation range ( e = 0.15), the resistivity decrease varies linearly with the initial contribution of local order to electrical resistivity. These effects are attributed to a destruction of the local order existing in the solid solutions, by the glide of dislocations during plastic deformation.

  17. Potential Operating Room Fire Hazard of Bone Cement.

    PubMed

    Sibia, Udai S; Connors, Kevin; Dyckman, Sarah; Zahiri, Hamid R; George, Ivan; Park, Adrian E; MacDonald, James H

    Approximately 600 cases of operating room (OR) fires are reported annually. Despite extensive fire safety education and training, complete elimination of OR fires still has not been achieved. Each fire requires an ignition source, a fuel source, and an oxidizer. In this case report, we describe the potential fire hazard of bone cement in the OR. A total knee arthroplasty was performed with a standard medial parapatellar arthrotomy. Tourniquet control was used. After bone cement was applied to the prepared tibial surface, the surgeon used an electrocautery device to resect residual lateral meniscus tissue-and started a fire in the operative field. The surgeon suffocated the fire with a dry towel and prevented injury to the patient. We performed a PubMed search with a cross-reference search for relevant papers and found no case reports outlining bone cement as a potential fire hazard in the OR. To our knowledge, this is the first case report identifying bone cement as a fire hazard. OR fires related to bone cement can be eliminated by correctly assessing the setting time of the cement and avoiding application sites during electrocautery.

  18. Automated Fall Detection With Quality Improvement “Rewind” to Reduce Falls in Hospital Rooms

    PubMed Central

    Rantz, Marilyn J.; Banerjee, Tanvi S.; Cattoor, Erin; Scott, Susan D.; Skubic, Marjorie; Popescu, Mihail

    2014-01-01

    The purpose of this study was to test the implementation of a fall detection and “rewind” privacy-protecting technique using the Microsoft® Kinect™ to not only detect but prevent falls from occurring in hospitalized patients. Kinect sensors were placed in six hospital rooms in a step-down unit and data were continuously logged. Prior to implementation with patients, three researchers performed a total of 18 falls (walking and then falling down or falling from the bed) and 17 non-fall events (crouching down, stooping down to tie shoe laces, and lying on the floor). All falls and non-falls were correctly identified using automated algorithms to process Kinect sensor data. During the first 8 months of data collection, processing methods were perfected to manage data and provide a “rewind” method to view events that led to falls for post-fall quality improvement process analyses. Preliminary data from this feasibility study show that using the Microsoft Kinect sensors provides detection of falls, fall risks, and facilitates quality improvement after falls in real hospital environments unobtrusively, while taking into account patient privacy. PMID:24296567

  19. Assessing the role of memory in preschoolers' performance on episodic foresight tasks.

    PubMed

    Atance, Cristina M; Sommerville, Jessica A

    2014-01-01

    A total of 48 preschoolers (ages 3, 4, and 5) received four tasks modelled after prior work designed to assess the development of "episodic foresight". For each task, children encountered a problem in one room and, after a brief delay, were given the opportunity in a second room to select an item to solve the problem. Importantly, after selecting an item, children were queried about their memory for the problem. Age-related changes were found both in children's ability to select the correct item and their ability to remember the problem. However, when we controlled for children's memory for the problem, there were no longer significant age-related changes on the item choice measure. These findings suggest that age-related changes in children's performance on these tasks are driven by improvements in children's memory versus improvements in children's future-oriented thinking or "foresight" per se. Our results have important implications for how best to structure tasks to measure children's episodic foresight, and also for the relative role of memory in this task and in episodic foresight more broadly.

  20. A Semantic Labeling of the Environment Based on What People Do.

    PubMed

    Crespo, Jonathan; Gómez, Clara; Hernández, Alejandra; Barber, Ramón

    2017-01-29

    In this work, a system is developed for semantic labeling of locations based on what people do. This system is useful for semantic navigation of mobile robots. The system differentiates environments according to what people do in them. Background sound, number of people in a room and amount of movement of those people are items to be considered when trying to tell if people are doing different actions. These data are sampled, and it is assumed that people behave differently and perform different actions. A support vector machine is trained with the obtained samples, and therefore, it allows one to identify the room. Finally, the results are discussed and support the hypothesis that the proposed system can help to semantically label a room.

Top