Sample records for baseline correction method

  1. An Automated Baseline Correction Method Based on Iterative Morphological Operations.

    PubMed

    Chen, Yunliang; Dai, Liankui

    2018-05-01

    Raman spectra usually suffer from baseline drift caused by fluorescence or other reasons. Therefore, baseline correction is a necessary and crucial step that must be performed before subsequent processing and analysis of Raman spectra. An automated baseline correction method based on iterative morphological operations is proposed in this work. The method can adaptively determine the structuring element first and then gradually remove the spectral peaks during iteration to get an estimated baseline. Experiments on simulated data and real-world Raman data show that the proposed method is accurate, fast, and flexible for handling different kinds of baselines in various practical situations. The comparison of the proposed method with some state-of-the-art baseline correction methods demonstrates its advantages over the existing methods in terms of accuracy, adaptability, and flexibility. Although only Raman spectra are investigated in this paper, the proposed method is hopefully to be used for the baseline correction of other analytical instrumental signals, such as IR spectra and chromatograms.

  2. Multi-objective optimization for an automated and simultaneous phase and baseline correction of NMR spectral data

    NASA Astrophysics Data System (ADS)

    Sawall, Mathias; von Harbou, Erik; Moog, Annekathrin; Behrens, Richard; Schröder, Henning; Simoneau, Joël; Steimers, Ellen; Neymeyr, Klaus

    2018-04-01

    Spectral data preprocessing is an integral and sometimes inevitable part of chemometric analyses. For Nuclear Magnetic Resonance (NMR) spectra a possible first preprocessing step is a phase correction which is applied to the Fourier transformed free induction decay (FID) signal. This preprocessing step can be followed by a separate baseline correction step. Especially if series of high-resolution spectra are considered, then automated and computationally fast preprocessing routines are desirable. A new method is suggested that applies the phase and the baseline corrections simultaneously in an automated form without manual input, which distinguishes this work from other approaches. The underlying multi-objective optimization or Pareto optimization provides improved results compared to consecutively applied correction steps. The optimization process uses an objective function which applies strong penalty constraints and weaker regularization conditions. The new method includes an approach for the detection of zero baseline regions. The baseline correction uses a modified Whittaker smoother. The functionality of the new method is demonstrated for experimental NMR spectra. The results are verified against gravimetric data. The method is compared to alternative preprocessing tools. Additionally, the simultaneous correction method is compared to a consecutive application of the two correction steps.

  3. [Baseline correction of spectrum for the inversion of chlorophyll-a concentration in the turbidity water].

    PubMed

    Wei, Yu-Chun; Wang, Guo-Xiang; Cheng, Chun-Mei; Zhang, Jing; Sun, Xiao-Peng

    2012-09-01

    Suspended particle material is the main factor affecting remote sensing inversion of chlorophyll-a concentration (Chla) in turbidity water. According to the optical property of suspended material in water, the present paper proposed a linear baseline correction method to weaken the suspended particle contribution in the spectrum above turbidity water surface. The linear baseline was defined as the connecting line of reflectance from 450 to 750 nm, and baseline correction is that spectrum reflectance subtracts the baseline. Analysis result of field data in situ of Meiliangwan, Taihu Lake in April, 2011 and March, 2010 shows that spectrum linear baseline correction can improve the inversion precision of Chl a and produce the better model diagnoses. As the data in March, 2010, RMSE of band ratio model built by original spectrum is 4.11 mg x m(-3), and that built by spectrum baseline correction is 3.58 mg x m(-3). Meanwhile, residual distribution and homoscedasticity in the model built by baseline correction spectrum is improved obviously. The model RMSE of April, 2011 shows the similar result. The authors suggest that using linear baseline correction as the spectrum processing method to improve Chla inversion accuracy in turbidity water without algae bloom.

  4. Comparison of fluorescence rejection methods of baseline correction and shifted excitation Raman difference spectroscopy

    NASA Astrophysics Data System (ADS)

    Cai, Zhijian; Zou, Wenlong; Wu, Jianhong

    2017-10-01

    Raman spectroscopy has been extensively used in biochemical tests, explosive detection, food additive and environmental pollutants. However, fluorescence disturbance brings a big trouble to the applications of portable Raman spectrometer. Currently, baseline correction and shifted-excitation Raman difference spectroscopy (SERDS) methods are the most prevailing fluorescence suppressing methods. In this paper, we compared the performances of baseline correction and SERDS methods, experimentally and simulatively. Through the comparison, it demonstrates that the baseline correction can get acceptable fluorescence-removed Raman spectrum if the original Raman signal has good signal-to-noise ratio, but it cannot recover the small Raman signals out of large noise background. By using SERDS method, the Raman signals, even very weak compared to fluorescence intensity and noise level, can be clearly extracted, and the fluorescence background can be completely rejected. The Raman spectrum recovered by SERDS has good signal to noise ratio. It's proved that baseline correction is more suitable for large bench-top Raman system with better quality or signal-to-noise ratio, while the SERDS method is more suitable for noisy devices, especially the portable Raman spectrometers.

  5. Single-Trial Normalization for Event-Related Spectral Decomposition Reduces Sensitivity to Noisy Trials

    PubMed Central

    Grandchamp, Romain; Delorme, Arnaud

    2011-01-01

    In electroencephalography, the classical event-related potential model often proves to be a limited method to study complex brain dynamics. For this reason, spectral techniques adapted from signal processing such as event-related spectral perturbation (ERSP) – and its variant event-related synchronization and event-related desynchronization – have been used over the past 20 years. They represent average spectral changes in response to a stimulus. These spectral methods do not have strong consensus for comparing pre- and post-stimulus activity. When computing ERSP, pre-stimulus baseline removal is usually performed after averaging the spectral estimate of multiple trials. Correcting the baseline of each single-trial prior to averaging spectral estimates is an alternative baseline correction method. However, we show that this method leads to positively skewed post-stimulus ERSP values. We eventually present new single-trial-based ERSP baseline correction methods that perform trial normalization or centering prior to applying classical baseline correction methods. We show that single-trial correction methods minimize the contribution of artifactual data trials with high-amplitude spectral estimates and are robust to outliers when performing statistical inference testing. We then characterize these methods in terms of their time–frequency responses and behavior compared to classical ERSP methods. PMID:21994498

  6. A novel approach for baseline correction in 1H-MRS signals based on ensemble empirical mode decomposition.

    PubMed

    Parto Dezfouli, Mohammad Ali; Dezfouli, Mohsen Parto; Rad, Hamidreza Saligheh

    2014-01-01

    Proton magnetic resonance spectroscopy ((1)H-MRS) is a non-invasive diagnostic tool for measuring biochemical changes in the human body. Acquired (1)H-MRS signals may be corrupted due to a wideband baseline signal generated by macromolecules. Recently, several methods have been developed for the correction of such baseline signals, however most of them are not able to estimate baseline in complex overlapped signal. In this study, a novel automatic baseline correction method is proposed for (1)H-MRS spectra based on ensemble empirical mode decomposition (EEMD). This investigation was applied on both the simulated data and the in-vivo (1)H-MRS of human brain signals. Results justify the efficiency of the proposed method to remove the baseline from (1)H-MRS signals.

  7. [A correction method of baseline drift of discrete spectrum of NIR].

    PubMed

    Hu, Ai-Qin; Yuan, Hong-Fu; Song, Chun-Feng; Li, Xiao-Yu

    2014-10-01

    In the present paper, a new correction method of baseline drift of discrete spectrum is proposed by combination of cubic spline interpolation and first order derivative. A fitting spectrum is constructed by cubic spline interpolation, using the datum in discrete spectrum as interpolation nodes. The fitting spectrum is differentiable. First order derivative is applied to the fitting spectrum to calculate derivative spectrum. The spectral wavelengths which are the same as the original discrete spectrum were taken out from the derivative spectrum to constitute the first derivative spectra of the discrete spectra, thereby to correct the baseline drift of the discrete spectra. The effects of the new method were demonstrated by comparison of the performances of multivariate models built using original spectra, direct differential spectra and the spectra pretreated by the new method. The results show that negative effects on the performance of multivariate model caused by baseline drift of discrete spectra can be effectively eliminated by the new method.

  8. A novel baseline correction method using convex optimization framework in laser-induced breakdown spectroscopy quantitative analysis

    NASA Astrophysics Data System (ADS)

    Yi, Cancan; Lv, Yong; Xiao, Han; Ke, Ke; Yu, Xun

    2017-12-01

    For laser-induced breakdown spectroscopy (LIBS) quantitative analysis technique, baseline correction is an essential part for the LIBS data preprocessing. As the widely existing cases, the phenomenon of baseline drift is generated by the fluctuation of laser energy, inhomogeneity of sample surfaces and the background noise, which has aroused the interest of many researchers. Most of the prevalent algorithms usually need to preset some key parameters, such as the suitable spline function and the fitting order, thus do not have adaptability. Based on the characteristics of LIBS, such as the sparsity of spectral peaks and the low-pass filtered feature of baseline, a novel baseline correction and spectral data denoising method is studied in this paper. The improved technology utilizes convex optimization scheme to form a non-parametric baseline correction model. Meanwhile, asymmetric punish function is conducted to enhance signal-noise ratio (SNR) of the LIBS signal and improve reconstruction precision. Furthermore, an efficient iterative algorithm is applied to the optimization process, so as to ensure the convergence of this algorithm. To validate the proposed method, the concentration analysis of Chromium (Cr),Manganese (Mn) and Nickel (Ni) contained in 23 certified high alloy steel samples is assessed by using quantitative models with Partial Least Squares (PLS) and Support Vector Machine (SVM). Because there is no prior knowledge of sample composition and mathematical hypothesis, compared with other methods, the method proposed in this paper has better accuracy in quantitative analysis, and fully reflects its adaptive ability.

  9. Motion artifact detection and correction in functional near-infrared spectroscopy: a new hybrid method based on spline interpolation method and Savitzky-Golay filtering.

    PubMed

    Jahani, Sahar; Setarehdan, Seyed K; Boas, David A; Yücel, Meryem A

    2018-01-01

    Motion artifact contamination in near-infrared spectroscopy (NIRS) data has become an important challenge in realizing the full potential of NIRS for real-life applications. Various motion correction algorithms have been used to alleviate the effect of motion artifacts on the estimation of the hemodynamic response function. While smoothing methods, such as wavelet filtering, are excellent in removing motion-induced sharp spikes, the baseline shifts in the signal remain after this type of filtering. Methods, such as spline interpolation, on the other hand, can properly correct baseline shifts; however, they leave residual high-frequency spikes. We propose a hybrid method that takes advantage of different correction algorithms. This method first identifies the baseline shifts and corrects them using a spline interpolation method or targeted principal component analysis. The remaining spikes, on the other hand, are corrected by smoothing methods: Savitzky-Golay (SG) filtering or robust locally weighted regression and smoothing. We have compared our new approach with the existing correction algorithms in terms of hemodynamic response function estimation using the following metrics: mean-squared error, peak-to-peak error ([Formula: see text]), Pearson's correlation ([Formula: see text]), and the area under the receiver operator characteristic curve. We found that spline-SG hybrid method provides reasonable improvements in all these metrics with a relatively short computational time. The dataset and the code used in this study are made available online for the use of all interested researchers.

  10. ALMA Long Baseline Campaigns: Phase Characteristics of Atmosphere at Long Baselines in the Millimeter and Submillimeter Wavelengths

    NASA Astrophysics Data System (ADS)

    Matsushita, Satoki; Asaki, Yoshiharu; Fomalont, Edward B.; Morita, Koh-Ichiro; Barkats, Denis; Hills, Richard E.; Kawabe, Ryohei; Maud, Luke T.; Nikolic, Bojan; Tilanus, Remo P. J.; Vlahakis, Catherine; Whyborn, Nicholas D.

    2017-03-01

    We present millimeter- and submillimeter-wave phase characteristics measured between 2012 and 2014 of Atacama Large Millimeter/submillimeter Array long baseline campaigns. This paper presents the first detailed investigation of the characteristics of phase fluctuation and phase correction methods obtained with baseline lengths up to ˜15 km. The basic phase fluctuation characteristics can be expressed with the spatial structure function (SSF). Most of the SSFs show that the phase fluctuation increases as a function of baseline length, with a power-law slope of ˜0.6. In many cases, we find that the slope becomes shallower (average of ˜0.2-0.3) at baseline lengths longer than ˜1 km, namely showing a turn-over in SSF. These power law slopes do not change with the amount of precipitable water vapor (PWV), but the fitted constants have a weak correlation with PWV, so that the phase fluctuation at a baseline length of 10 km also increases as a function of PWV. The phase correction method using water vapor radiometers (WVRs) works well, especially for the cases where PWV > 1 {mm}, which reduces the degree of phase fluctuations by a factor of two in many cases. However, phase fluctuations still remain after the WVR phase correction, suggesting the existence of other turbulent constituent that cause the phase fluctuation. This is supported by occasional SSFs that do not exhibit any turn-over; these are only seen when the PWV is low (i.e., when the WVR phase correction works less effectively) or after WVR phase correction. This means that the phase fluctuation caused by this turbulent constituent is inherently smaller than that caused by water vapor. Since in these rare cases there is no turn-over in the SSF up to the maximum baseline length of ˜15 km, this turbulent constituent must have scale height of 10 km or more, and thus cannot be water vapor, whose scale height is around 1 km. Based on the characteristics, this large scale height turbulent constituent is likely to be water ice or a dry component. Excess path length fluctuation after the WVR phase correction at a baseline length of 10 km is large (≳ 200 μ {{m}}), which is significant for high frequency (> 450 {GHz} or < 700 μ {{m}}) observations. These results suggest the need for an additional phase correction method to reduce the degree of phase fluctuation, such as fast switching, in addition to the WVR phase correction. We simulated the fast switching phase correction method using observations of single quasars, and the result suggests that it works well, with shorter cycle times linearly improving the coherence.

  11. A novel baseline-correction method for standard addition based derivative spectra and its application to quantitative analysis of benzo(a)pyrene in vegetable oil samples.

    PubMed

    Li, Na; Li, Xiu-Ying; Zou, Zhe-Xiang; Lin, Li-Rong; Li, Yao-Qun

    2011-07-07

    In the present work, a baseline-correction method based on peak-to-derivative baseline measurement was proposed for the elimination of complex matrix interference that was mainly caused by unknown components and/or background in the analysis of derivative spectra. This novel method was applicable particularly when the matrix interfering components showed a broad spectral band, which was common in practical analysis. The derivative baseline was established by connecting two crossing points of the spectral curves obtained with a standard addition method (SAM). The applicability and reliability of the proposed method was demonstrated through both theoretical simulation and practical application. Firstly, Gaussian bands were used to simulate 'interfering' and 'analyte' bands to investigate the effect of different parameters of interfering band on the derivative baseline. This simulation analysis verified that the accuracy of the proposed method was remarkably better than other conventional methods such as peak-to-zero, tangent, and peak-to-peak measurements. Then the above proposed baseline-correction method was applied to the determination of benzo(a)pyrene (BaP) in vegetable oil samples by second-derivative synchronous fluorescence spectroscopy. The satisfactory results were obtained by using this new method to analyze a certified reference material (coconut oil, BCR(®)-458) with a relative error of -3.2% from the certified BaP concentration. Potentially, the proposed method can be applied to various types of derivative spectra in different fields such as UV-visible absorption spectroscopy, fluorescence spectroscopy and infrared spectroscopy.

  12. Leveraging probabilistic peak detection to estimate baseline drift in complex chromatographic samples.

    PubMed

    Lopatka, Martin; Barcaru, Andrei; Sjerps, Marjan J; Vivó-Truyols, Gabriel

    2016-01-29

    Accurate analysis of chromatographic data often requires the removal of baseline drift. A frequently employed strategy strives to determine asymmetric weights in order to fit a baseline model by regression. Unfortunately, chromatograms characterized by a very high peak saturation pose a significant challenge to such algorithms. In addition, a low signal-to-noise ratio (i.e. s/n<40) also adversely affects accurate baseline correction by asymmetrically weighted regression. We present a baseline estimation method that leverages a probabilistic peak detection algorithm. A posterior probability of being affected by a peak is computed for each point in the chromatogram, leading to a set of weights that allow non-iterative calculation of a baseline estimate. For extremely saturated chromatograms, the peak weighted (PW) method demonstrates notable improvement compared to the other methods examined. However, in chromatograms characterized by low-noise and well-resolved peaks, the asymmetric least squares (ALS) and the more sophisticated Mixture Model (MM) approaches achieve superior results in significantly less time. We evaluate the performance of these three baseline correction methods over a range of chromatographic conditions to demonstrate the cases in which each method is most appropriate. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Increasing conclusiveness of clinical breath analysis by improved baseline correction of multi capillary column - ion mobility spectrometry (MCC-IMS) data.

    PubMed

    Szymańska, Ewa; Tinnevelt, Gerjen H; Brodrick, Emma; Williams, Mark; Davies, Antony N; van Manen, Henk-Jan; Buydens, Lutgarde M C

    2016-08-05

    Current challenges of clinical breath analysis include large data size and non-clinically relevant variations observed in exhaled breath measurements, which should be urgently addressed with competent scientific data tools. In this study, three different baseline correction methods are evaluated within a previously developed data size reduction strategy for multi capillary column - ion mobility spectrometry (MCC-IMS) datasets. Introduced for the first time in breath data analysis, the Top-hat method is presented as the optimum baseline correction method. A refined data size reduction strategy is employed in the analysis of a large breathomic dataset on a healthy and respiratory disease population. New insights into MCC-IMS spectra differences associated with respiratory diseases are provided, demonstrating the additional value of the refined data analysis strategy in clinical breath analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. A Simple Method to Control Positive Baseline Trend within Data Nonoverlap

    ERIC Educational Resources Information Center

    Parker, Richard I.; Vannest, Kimberly J.; Davis, John L.

    2014-01-01

    Nonoverlap is widely used as a statistical summary of data; however, these analyses rarely correct unwanted positive baseline trend. This article presents and validates the graph rotation for overlap and trend (GROT) technique, a hand calculation method for controlling positive baseline trend within an analysis of data nonoverlap. GROT is…

  15. Simple automatic strategy for background drift correction in chromatographic data analysis.

    PubMed

    Fu, Hai-Yan; Li, He-Dong; Yu, Yong-Jie; Wang, Bing; Lu, Peng; Cui, Hua-Peng; Liu, Ping-Ping; She, Yuan-Bin

    2016-06-03

    Chromatographic background drift correction, which influences peak detection and time shift alignment results, is a critical stage in chromatographic data analysis. In this study, an automatic background drift correction methodology was developed. Local minimum values in a chromatogram were initially detected and organized as a new baseline vector. Iterative optimization was then employed to recognize outliers, which belong to the chromatographic peaks, in this vector, and update the outliers in the baseline until convergence. The optimized baseline vector was finally expanded into the original chromatogram, and linear interpolation was employed to estimate background drift in the chromatogram. The principle underlying the proposed method was confirmed using a complex gas chromatographic dataset. Finally, the proposed approach was applied to eliminate background drift in liquid chromatography quadrupole time-of-flight samples used in the metabolic study of Escherichia coli samples. The proposed method was comparable with three classical techniques: morphological weighted penalized least squares, moving window minimum value strategy and background drift correction by orthogonal subspace projection. The proposed method allows almost automatic implementation of background drift correction, which is convenient for practical use. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Baseline Correction of Diffuse Reflection Near-Infrared Spectra Using Searching Region Standard Normal Variate (SRSNV).

    PubMed

    Genkawa, Takuma; Shinzawa, Hideyuki; Kato, Hideaki; Ishikawa, Daitaro; Murayama, Kodai; Komiyama, Makoto; Ozaki, Yukihiro

    2015-12-01

    An alternative baseline correction method for diffuse reflection near-infrared (NIR) spectra, searching region standard normal variate (SRSNV), was proposed. Standard normal variate (SNV) is an effective pretreatment method for baseline correction of diffuse reflection NIR spectra of powder and granular samples; however, its baseline correction performance depends on the NIR region used for SNV calculation. To search for an optimal NIR region for baseline correction using SNV, SRSNV employs moving window partial least squares regression (MWPLSR), and an optimal NIR region is identified based on the root mean square error (RMSE) of cross-validation of the partial least squares regression (PLSR) models with the first latent variable (LV). The performance of SRSNV was evaluated using diffuse reflection NIR spectra of mixture samples consisting of wheat flour and granular glucose (0-100% glucose at 5% intervals). From the obtained NIR spectra of the mixture in the 10 000-4000 cm(-1) region at 4 cm intervals (1501 spectral channels), a series of spectral windows consisting of 80 spectral channels was constructed, and then SNV spectra were calculated for each spectral window. Using these SNV spectra, a series of PLSR models with the first LV for glucose concentration was built. A plot of RMSE versus the spectral window position obtained using the PLSR models revealed that the 8680–8364 cm(-1) region was optimal for baseline correction using SNV. In the SNV spectra calculated using the 8680–8364 cm(-1) region (SRSNV spectra), a remarkable relative intensity change between a band due to wheat flour at 8500 cm(-1) and that due to glucose at 8364 cm(-1) was observed owing to successful baseline correction using SNV. A PLSR model with the first LV based on the SRSNV spectra yielded a determination coefficient (R2) of 0.999 and an RMSE of 0.70%, while a PLSR model with three LVs based on SNV spectra calculated in the full spectral region gave an R2 of 0.995 and an RMSE of 2.29%. Additional evaluation of SRSNV was carried out using diffuse reflection NIR spectra of marzipan and corn samples, and PLSR models based on SRSNV spectra showed good prediction results. These evaluation results indicate that SRSNV is effective in baseline correction of diffuse reflection NIR spectra and provides regression models with good prediction accuracy.

  17. Method and apparatus for reliable inter-antenna baseline determination

    NASA Technical Reports Server (NTRS)

    Wilson, John M. (Inventor)

    2001-01-01

    Disclosed is a method for inter-antenna baseline determination that uses an antenna configuration comprising a pair of relatively closely spaced antennas and other pairs of distant antennas. The closely spaced pair provides a short baseline having an integer ambiguity that may be searched exhaustively to identify the correct set of integers. This baseline is then used as a priori information to aid the determination of longer baselines that, once determined, may be used for accurate run time attitude determination.

  18. An Improved Rank Correlation Effect Size Statistic for Single-Case Designs: Baseline Corrected Tau.

    PubMed

    Tarlow, Kevin R

    2017-07-01

    Measuring treatment effects when an individual's pretreatment performance is improving poses a challenge for single-case experimental designs. It may be difficult to determine whether improvement is due to the treatment or due to the preexisting baseline trend. Tau- U is a popular single-case effect size statistic that purports to control for baseline trend. However, despite its strengths, Tau- U has substantial limitations: Its values are inflated and not bound between -1 and +1, it cannot be visually graphed, and its relatively weak method of trend control leads to unacceptable levels of Type I error wherein ineffective treatments appear effective. An improved effect size statistic based on rank correlation and robust regression, Baseline Corrected Tau, is proposed and field-tested with both published and simulated single-case time series. A web-based calculator for Baseline Corrected Tau is also introduced for use by single-case investigators.

  19. Development of an approach to correcting MicroPEM baseline drift.

    PubMed

    Zhang, Ting; Chillrud, Steven N; Pitiranggon, Masha; Ross, James; Ji, Junfeng; Yan, Beizhan

    2018-07-01

    Fine particulate matter (PM 2.5 ) is associated with various adverse health outcomes. The MicroPEM (RTI, NC), a miniaturized real-time portable particulate sensor with an integrated filter for collecting particles, has been widely used for personal PM 2.5 exposure assessment. Five-day deployments were targeted on a total of 142 deployments (personal or residential) to obtain real-time PM 2.5 levels from children living in New York City and Baltimore. Among these 142 deployments, 79 applied high-efficiency particulate air (HEPA) filters in the field at the beginning and end of each deployment to adjust the zero level of the nephelometer. However, unacceptable baseline drift was observed in a large fraction (> 40%) of acquisitions in this study even after HEPA correction. This drift issue has been observed in several other studies as well. The purpose of the present study is to develop an algorithm to correct the baseline drift in MicroPEM based on central site ambient data during inactive time periods. A running baseline & gravimetric correction (RBGC) method was developed based on the comparison of MicroPEM readings during inactive periods to ambient PM 2.5 levels provided by fixed monitoring sites and the gravimetric weight of PM 2.5 collected on the MicroPEM filters. The results after RBGC correction were compared with those using HEPA approach and gravimetric correction alone. Seven pairs of duplicate acquisitions were used to validate the RBGC method. The percentages of acquisitions with baseline drift problems were 42%, 53% and 10% for raw, HEPA corrected, and RBGC corrected data, respectively. Pearson correlation analysis of duplicates showed an increase in the coefficient of determination from 0.75 for raw data to 0.97 after RBGC correction. In addition, the slope of the regression line increased from 0.60 for raw data to 1.00 after RBGC correction. The RBGC approach corrected the baseline drift issue associated with MicroPEM data. The algorithm developed has the potential for use with data generated from other types of PM sensors that contain a filter for weighing as well. In addition, this approach can be applied in many other regions, given widely available ambient PM data from monitoring networks, especially in urban areas. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Multivariate qualitative analysis of banned additives in food safety using surface enhanced Raman scattering spectroscopy

    NASA Astrophysics Data System (ADS)

    He, Shixuan; Xie, Wanyi; Zhang, Wei; Zhang, Liqun; Wang, Yunxia; Liu, Xiaoling; Liu, Yulong; Du, Chunlei

    2015-02-01

    A novel strategy which combines iteratively cubic spline fitting baseline correction method with discriminant partial least squares qualitative analysis is employed to analyze the surface enhanced Raman scattering (SERS) spectroscopy of banned food additives, such as Sudan I dye and Rhodamine B in food, Malachite green residues in aquaculture fish. Multivariate qualitative analysis methods, using the combination of spectra preprocessing iteratively cubic spline fitting (ICSF) baseline correction with principal component analysis (PCA) and discriminant partial least squares (DPLS) classification respectively, are applied to investigate the effectiveness of SERS spectroscopy for predicting the class assignments of unknown banned food additives. PCA cannot be used to predict the class assignments of unknown samples. However, the DPLS classification can discriminate the class assignment of unknown banned additives using the information of differences in relative intensities. The results demonstrate that SERS spectroscopy combined with ICSF baseline correction method and exploratory analysis methodology DPLS classification can be potentially used for distinguishing the banned food additives in field of food safety.

  1. Safe and sensible preprocessing and baseline correction of pupil-size data.

    PubMed

    Mathôt, Sebastiaan; Fabius, Jasper; Van Heusden, Elle; Van der Stigchel, Stefan

    2018-02-01

    Measurement of pupil size (pupillometry) has recently gained renewed interest from psychologists, but there is little agreement on how pupil-size data is best analyzed. Here we focus on one aspect of pupillometric analyses: baseline correction, i.e., analyzing changes in pupil size relative to a baseline period. Baseline correction is useful in experiments that investigate the effect of some experimental manipulation on pupil size. In such experiments, baseline correction improves statistical power by taking into account random fluctuations in pupil size over time. However, we show that baseline correction can also distort data if unrealistically small pupil sizes are recorded during the baseline period, which can easily occur due to eye blinks, data loss, or other distortions. Divisive baseline correction (corrected pupil size = pupil size/baseline) is affected more strongly by such distortions than subtractive baseline correction (corrected pupil size = pupil size - baseline). We discuss the role of baseline correction as a part of preprocessing of pupillometric data, and make five recommendations: (1) before baseline correction, perform data preprocessing to mark missing and invalid data, but assume that some distortions will remain in the data; (2) use subtractive baseline correction; (3) visually compare your corrected and uncorrected data; (4) be wary of pupil-size effects that emerge faster than the latency of the pupillary response allows (within ±220 ms after the manipulation that induces the effect); and (5) remove trials on which baseline pupil size is unrealistically small (indicative of blinks and other distortions).

  2. A newly identified calculation discrepancy of the Sunset semi-continuous carbon analyzer

    NASA Astrophysics Data System (ADS)

    Zheng, G.; Cheng, Y.; He, K.; Duan, F.; Ma, Y.

    2014-01-01

    Sunset Semi-Continuous Carbon Analyzer (SCCA) is an instrument widely used for carbonaceous aerosol measurement. Despite previous validation work, here we identified a new type of SCCA calculation discrepancy caused by the default multi-point baseline correction method. When exceeding a certain threshold carbon load, multi-point correction could cause significant Total Carbon (TC) underestimation. This calculation discrepancy was characterized for both sucrose and ambient samples with three temperature protocols. For ambient samples, 22%, 36% and 12% TC was underestimated by the three protocols, respectively, with corresponding threshold being ~0, 20 and 25 μg C. For sucrose, however, such discrepancy was observed with only one of these protocols, indicating the need of more refractory SCCA calibration substance. The discrepancy was less significant for the NIOSH (National Institute for Occupational Safety and Health)-like protocol compared with the other two protocols based on IMPROVE (Interagency Monitoring of PROtected Visual Environments). Although the calculation discrepancy could be largely reduced by the single-point baseline correction method, the instrumental blanks of single-point method were higher. Proposed correction method was to use multi-point corrected data when below the determined threshold, while use single-point results when beyond that threshold. The effectiveness of this correction method was supported by correlation with optical data.

  3. A newly identified calculation discrepancy of the Sunset semi-continuous carbon analyzer

    NASA Astrophysics Data System (ADS)

    Zheng, G. J.; Cheng, Y.; He, K. B.; Duan, F. K.; Ma, Y. L.

    2014-07-01

    The Sunset semi-continuous carbon analyzer (SCCA) is an instrument widely used for carbonaceous aerosol measurement. Despite previous validation work, in this study we identified a new type of SCCA calculation discrepancy caused by the default multipoint baseline correction method. When exceeding a certain threshold carbon load, multipoint correction could cause significant total carbon (TC) underestimation. This calculation discrepancy was characterized for both sucrose and ambient samples, with two protocols based on IMPROVE (Interagency Monitoring of PROtected Visual Environments) (i.e., IMPshort and IMPlong) and one NIOSH (National Institute for Occupational Safety and Health)-like protocol (rtNIOSH). For ambient samples, the IMPshort, IMPlong and rtNIOSH protocol underestimated 22, 36 and 12% of TC, respectively, with the corresponding threshold being ~ 0, 20 and 25 μgC. For sucrose, however, such discrepancy was observed only with the IMPshort protocol, indicating the need of more refractory SCCA calibration substance. Although the calculation discrepancy could be largely reduced by the single-point baseline correction method, the instrumental blanks of single-point method were higher. The correction method proposed was to use multipoint-corrected data when below the determined threshold, and use single-point results when beyond that threshold. The effectiveness of this correction method was supported by correlation with optical data.

  4. Atmospheric phase characteristics of the ALMA long baseline

    NASA Astrophysics Data System (ADS)

    Matsushita, Satoki; Asaki, Yoshiharu; Fomalont, Edward B.; Barkats, Denis; Corder, Stuartt A.; Hills, Richard E.; Kawabe, Ryohei; Maud, Luke T.; Morita, Koh-Ichiro; Nikolic, Bojan; Tilanus, Remo P. J.; Vlahakis, Catherine

    2016-07-01

    Atacama Large Millimeter/submillimeter Array (ALMA) is the world's largest millimeter/ submillimeter (mm / Submm) interferometer. Along with science observations, ALMA has performed several long baseline campaigns in the last 6 years to characterize and optimize its long baseline capabilities. To achieve full long baseline capability of ALMA, it is important to understand the characteristics of atmospheric phase fluctuation at long baselines, since it is believed to be the main cause of mm/submm image degradation. For the first time, we present detailed properties of atmospheric phase fluctuation at mm/submm wavelength from baselines up to 15 km in length. Atmospheric phase fluctuation increases as a function of baseline length with a power-law slope close to 0.6, and many of the data display a shallower slope (02.-03) at baseline length greater than about 15 km. Some of the data, on the other hand, show a single slope up to the maximum baseline length of around 15 km. The phase correction method based on water vapor radiometers (WVRs) works well, especially for cases with precipitable water vapor (PWV) greater than 1 mm, typically yielding a 50% decrease or more in the degree of phase fluctuation. However, signicant amount of atmospheric phase fluctuation still remains after the WVR phase correction: about 200 micron in rms excess path length (rms phase fluctuation in unit of length) even at PWV less than 1 mm. This result suggests the existence of other non-water-vapor sources of phase fluctuation. and emphasizes the need for additional phase correction methods, such as band-to-band and/or fast switching.

  5. Multivariate qualitative analysis of banned additives in food safety using surface enhanced Raman scattering spectroscopy.

    PubMed

    He, Shixuan; Xie, Wanyi; Zhang, Wei; Zhang, Liqun; Wang, Yunxia; Liu, Xiaoling; Liu, Yulong; Du, Chunlei

    2015-02-25

    A novel strategy which combines iteratively cubic spline fitting baseline correction method with discriminant partial least squares qualitative analysis is employed to analyze the surface enhanced Raman scattering (SERS) spectroscopy of banned food additives, such as Sudan I dye and Rhodamine B in food, Malachite green residues in aquaculture fish. Multivariate qualitative analysis methods, using the combination of spectra preprocessing iteratively cubic spline fitting (ICSF) baseline correction with principal component analysis (PCA) and discriminant partial least squares (DPLS) classification respectively, are applied to investigate the effectiveness of SERS spectroscopy for predicting the class assignments of unknown banned food additives. PCA cannot be used to predict the class assignments of unknown samples. However, the DPLS classification can discriminate the class assignment of unknown banned additives using the information of differences in relative intensities. The results demonstrate that SERS spectroscopy combined with ICSF baseline correction method and exploratory analysis methodology DPLS classification can be potentially used for distinguishing the banned food additives in field of food safety. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. An automated baseline correction protocol for infrared spectra of atmospheric aerosols collected on polytetrafluoroethylene (Teflon) filters

    NASA Astrophysics Data System (ADS)

    Kuzmiakova, Adele; Dillner, Ann M.; Takahama, Satoshi

    2016-06-01

    A growing body of research on statistical applications for characterization of atmospheric aerosol Fourier transform infrared (FT-IR) samples collected on polytetrafluoroethylene (PTFE) filters (e.g., Russell et al., 2011; Ruthenburg et al., 2014) and a rising interest in analyzing FT-IR samples collected by air quality monitoring networks call for an automated PTFE baseline correction solution. The existing polynomial technique (Takahama et al., 2013) is not scalable to a project with a large number of aerosol samples because it contains many parameters and requires expert intervention. Therefore, the question of how to develop an automated method for baseline correcting hundreds to thousands of ambient aerosol spectra given the variability in both environmental mixture composition and PTFE baselines remains. This study approaches the question by detailing the statistical protocol, which allows for the precise definition of analyte and background subregions, applies nonparametric smoothing splines to reproduce sample-specific PTFE variations, and integrates performance metrics from atmospheric aerosol and blank samples alike in the smoothing parameter selection. Referencing 794 atmospheric aerosol samples from seven Interagency Monitoring of PROtected Visual Environment (IMPROVE) sites collected during 2011, we start by identifying key FT-IR signal characteristics, such as non-negative absorbance or analyte segment transformation, to capture sample-specific transitions between background and analyte. While referring to qualitative properties of PTFE background, the goal of smoothing splines interpolation is to learn the baseline structure in the background region to predict the baseline structure in the analyte region. We then validate the model by comparing smoothing splines baseline-corrected spectra with uncorrected and polynomial baseline (PB)-corrected equivalents via three statistical applications: (1) clustering analysis, (2) functional group quantification, and (3) thermal optical reflectance (TOR) organic carbon (OC) and elemental carbon (EC) predictions. The discrepancy rate for a four-cluster solution is 10 %. For all functional groups but carboxylic COH the discrepancy is ≤ 10 %. Performance metrics obtained from TOR OC and EC predictions (R2 ≥ 0.94 %, bias ≤ 0.01 µg m-3, and error ≤ 0.04 µg m-3) are on a par with those obtained from uncorrected and PB-corrected spectra. The proposed protocol leads to visually and analytically similar estimates as those generated by the polynomial method. More importantly, the automated solution allows us and future users to evaluate its analytical reproducibility while minimizing reducible user bias. We anticipate the protocol will enable FT-IR researchers and data analysts to quickly and reliably analyze a large amount of data and connect them to a variety of available statistical learning methods to be applied to analyte absorbances isolated in atmospheric aerosol samples.

  7. A New Statistics-Based Online Baseline Restorer for a High Count-Rate Fully Digital System.

    PubMed

    Li, Hongdi; Wang, Chao; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio; Liu, Shitao; An, Shaohui; Wong, Wai-Hoi

    2010-04-01

    The goal of this work is to develop a novel, accurate, real-time digital baseline restorer using online statistical processing for a high count-rate digital system such as positron emission tomography (PET). In high count-rate nuclear instrumentation applications, analog signals are DC-coupled for better performance. However, the detectors, pre-amplifiers and other front-end electronics would cause a signal baseline drift in a DC-coupling system, which will degrade the performance of energy resolution and positioning accuracy. Event pileups normally exist in a high-count rate system and the baseline drift will create errors in the event pileup-correction. Hence, a baseline restorer (BLR) is required in a high count-rate system to remove the DC drift ahead of the pileup correction. Many methods have been reported for BLR from classic analog methods to digital filter solutions. However a single channel BLR with analog method can only work under 500 kcps count-rate, and normally an analog front-end application-specific integrated circuits (ASIC) is required for the application involved hundreds BLR such as a PET camera. We have developed a simple statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system. In this method, we acquire additional samples, excluding the real gamma pulses, from the existing free-running ADC in the digital system, and perform online statistical processing to generate a baseline value. This baseline value will be subtracted from the digitized waveform to retrieve its original pulse with zero-baseline drift. This method can self-track the baseline without a micro-controller involved. The circuit consists of two digital counter/timers, one comparator, one register and one subtraction unit. Simulation shows a single channel works at 30 Mcps count-rate with pileup condition. 336 baseline restorer circuits have been implemented into 12 field-programmable-gate-arrays (FPGA) for our new fully digital PET system.

  8. Application of a net-based baseline correction scheme to strong-motion records of the 2011 Mw 9.0 Tohoku earthquake

    NASA Astrophysics Data System (ADS)

    Tu, Rui; Wang, Rongjiang; Zhang, Yong; Walter, Thomas R.

    2014-06-01

    The description of static displacements associated with earthquakes is traditionally achieved using GPS, EDM or InSAR data. In addition, displacement histories can be derived from strong-motion records, allowing an improvement of geodetic networks at a high sampling rate and a better physical understanding of earthquake processes. Strong-motion records require a correction procedure appropriate for baseline shifts that may be caused by rotational motion, tilting and other instrumental effects. Common methods use an empirical bilinear correction on the velocity seismograms integrated from the strong-motion records. In this study, we overcome the weaknesses of an empirically based bilinear baseline correction scheme by using a net-based criterion to select the timing parameters. This idea is based on the physical principle that low-frequency seismic waveforms at neighbouring stations are coherent if the interstation distance is much smaller than the distance to the seismic source. For a dense strong-motion network, it is plausible to select the timing parameters so that the correlation coefficient between the velocity seismograms of two neighbouring stations is maximized after the baseline correction. We applied this new concept to the KiK-Net and K-Net strong-motion data available for the 2011 Mw 9.0 Tohoku earthquake. We compared the derived coseismic static displacement with high-quality GPS data, and with the results obtained using empirical methods. The results show that the proposed net-based approach is feasible and more robust than the individual empirical approaches. The outliers caused by unknown problems in the measurement system can be easily detected and quantified.

  9. Helicopter Noise Reduction Design Trade-Off Study

    DTIC Science & Technology

    1977-01-01

    level, A-weighted sound pressure level, perceived noise level and tone corrected perceived noise level time histories, and are further analyzed to...DATA ---------------------------- 101 10 BASELINE VEHICLE EFFECTIVE PERCEIVED NOISE LEVELS (EPiII.) AND RANGE FOR MAXIMIJM TONE CORRECTED PERCEIVED...and tone corrected perceived noise level (PNLT) units. All noise level calculation methods have been computerized in FORTRAN language for use on the

  10. A robust automatic phase correction method for signal dense spectra

    NASA Astrophysics Data System (ADS)

    Bao, Qingjia; Feng, Jiwen; Chen, Li; Chen, Fang; Liu, Zao; Jiang, Bin; Liu, Chaoyang

    2013-09-01

    A robust automatic phase correction method for Nuclear Magnetic Resonance (NMR) spectra is presented. In this work, a new strategy combining ‘coarse tuning' with ‘fine tuning' is introduced to correct various spectra accurately. In the ‘coarse tuning' procedure, a new robust baseline recognition method is proposed for determining the positions of the tail ends of the peaks, and then the preliminary phased spectra are obtained by minimizing the objective function based on the height difference of these tail ends. After the ‘coarse tuning', the peaks in the preliminary corrected spectra can be categorized into three classes: positive, negative, and distorted. Based on the classification result, a new custom negative penalty function used in the step of ‘fine tuning' is constructed to avoid the negative peak points in the spectra excluded in the negative peaks and distorted peaks. Finally, the fine phased spectra can be obtained by minimizing the custom negative penalty function. This method is proven to be very robust for it is tolerant to low signal-to-noise ratio, large baseline distortion and independent of the starting search points of phasing parameters. The experimental results on both 1D metabonomics spectra with over-crowded peaks and 2D spectra demonstrate the high efficiency of this automatic method.

  11. GNSS Single Frequency, Single Epoch Reliable Attitude Determination Method with Baseline Vector Constraint.

    PubMed

    Gong, Ang; Zhao, Xiubin; Pang, Chunlei; Duan, Rong; Wang, Yong

    2015-12-02

    For Global Navigation Satellite System (GNSS) single frequency, single epoch attitude determination, this paper proposes a new reliable method with baseline vector constraint. First, prior knowledge of baseline length, heading, and pitch obtained from other navigation equipment or sensors are used to reconstruct objective function rigorously. Then, searching strategy is improved. It substitutes gradually Enlarged ellipsoidal search space for non-ellipsoidal search space to ensure correct ambiguity candidates are within it and make the searching process directly be carried out by least squares ambiguity decorrelation algorithm (LAMBDA) method. For all vector candidates, some ones are further eliminated by derived approximate inequality, which accelerates the searching process. Experimental results show that compared to traditional method with only baseline length constraint, this new method can utilize a priori baseline three-dimensional knowledge to fix ambiguity reliably and achieve a high success rate. Experimental tests also verify it is not very sensitive to baseline vector error and can perform robustly when angular error is not great.

  12. An Ensemble Method for Spelling Correction in Consumer Health Questions

    PubMed Central

    Kilicoglu, Halil; Fiszman, Marcelo; Roberts, Kirk; Demner-Fushman, Dina

    2015-01-01

    Orthographic and grammatical errors are a common feature of informal texts written by lay people. Health-related questions asked by consumers are a case in point. Automatic interpretation of consumer health questions is hampered by such errors. In this paper, we propose a method that combines techniques based on edit distance and frequency counts with a contextual similarity-based method for detecting and correcting orthographic errors, including misspellings, word breaks, and punctuation errors. We evaluate our method on a set of spell-corrected questions extracted from the NLM collection of consumer health questions. Our method achieves a F1 score of 0.61, compared to an informed baseline of 0.29, achieved using ESpell, a spelling correction system developed for biomedical queries. Our results show that orthographic similarity is most relevant in spelling error correction in consumer health questions and that frequency and contextual information are complementary to orthographic features. PMID:26958208

  13. Should Studies of Diabetes Treatment Stratification Correct for Baseline HbA1c?

    PubMed Central

    Jones, Angus G.; Lonergan, Mike; Henley, William E.; Pearson, Ewan R.; Hattersley, Andrew T.; Shields, Beverley M.

    2016-01-01

    Aims Baseline HbA1c is a major predictor of response to glucose lowering therapy and therefore a potential confounder in studies aiming to identify other predictors. However, baseline adjustment may introduce error if the association between baseline HbA1c and response is substantially due to measurement error and regression to the mean. We aimed to determine whether studies of predictors of response should adjust for baseline HbA1c. Methods We assessed the relationship between baseline HbA1c and glycaemic response in 257 participants treated with GLP-1R agonists and assessed whether it reflected measurement error and regression to the mean using duplicate ‘pre-baseline’ HbA1c measurements not included in the response variable. In this cohort and an additional 2659 participants treated with sulfonylureas we assessed the relationship between covariates associated with baseline HbA1c and treatment response with and without baseline adjustment, and with a bias correction using pre-baseline HbA1c to adjust for the effects of error in baseline HbA1c. Results Baseline HbA1c was a major predictor of response (R2 = 0.19,β = -0.44,p<0.001).The association between pre-baseline and response was similar suggesting the greater response at higher baseline HbA1cs is not mainly due to measurement error and subsequent regression to the mean. In unadjusted analysis in both cohorts, factors associated with baseline HbA1c were associated with response, however these associations were weak or absent after adjustment for baseline HbA1c. Bias correction did not substantially alter associations. Conclusions Adjustment for the baseline HbA1c measurement is a simple and effective way to reduce bias in studies of predictors of response to glucose lowering therapy. PMID:27050911

  14. Surface dose measurements with commonly used detectors: a consistent thickness correction method.

    PubMed

    Reynolds, Tatsiana A; Higgins, Patrick

    2015-09-08

    The purpose of this study was to review application of a consistent correction method for the solid state detectors, such as thermoluminescent dosimeters (chips (cTLD) and powder (pTLD)), optically stimulated detectors (both closed (OSL) and open (eOSL)), and radiochromic (EBT2) and radiographic (EDR2) films. In addition, to compare measured surface dose using an extrapolation ionization chamber (PTW 30-360) with other parallel plate chambers RMI-449 (Attix), Capintec PS-033, PTW 30-329 (Markus) and Memorial. Measurements of surface dose for 6MV photons with parallel plate chambers were used to establish a baseline. cTLD, OSLs, EDR2, and EBT2 measurements were corrected using a method which involved irradiation of three dosimeter stacks, followed by linear extrapolation of individual dosimeter measurements to zero thickness. We determined the magnitude of correction for each detector and compared our results against an alternative correction method based on effective thickness. All uncorrected surface dose measurements exhibited overresponse, compared with the extrapolation chamber data, except for the Attix chamber. The closest match was obtained with the Attix chamber (-0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EBT2 (14%), EDR2 (14.8%), and OSL (26%). Application of published ionization chamber corrections brought all the parallel plate results to within 1% of the extrapolation chamber. The extrapolation method corrected all solid-state detector results to within 2% of baseline, except the OSLs. Extrapolation of dose using a simple three-detector stack has been demonstrated to provide thickness corrections for cTLD, eOSLs, EBT2, and EDR2 which can then be used for surface dose measurements. Standard OSLs are not recommended for surface dose measurement. The effective thickness method suffers from the subjectivity inherent in the inclusion of measured percentage depth-dose curves and is not recommended for these types of measurements.

  15. Goldindec: A Novel Algorithm for Raman Spectrum Baseline Correction

    PubMed Central

    Liu, Juntao; Sun, Jianyang; Huang, Xiuzhen; Li, Guojun; Liu, Binqiang

    2016-01-01

    Raman spectra have been widely used in biology, physics, and chemistry and have become an essential tool for the studies of macromolecules. Nevertheless, the raw Raman signal is often obscured by a broad background curve (or baseline) due to the intrinsic fluorescence of the organic molecules, which leads to unpredictable negative effects in quantitative analysis of Raman spectra. Therefore, it is essential to correct this baseline before analyzing raw Raman spectra. Polynomial fitting has proven to be the most convenient and simplest method and has high accuracy. In polynomial fitting, the cost function used and its parameters are crucial. This article proposes a novel iterative algorithm named Goldindec, freely available for noncommercial use as noted in text, with a new cost function that not only conquers the influence of great peaks but also solves the problem of low correction accuracy when there is a high peak number. Goldindec automatically generates parameters from the raw data rather than by empirical choice, as in previous methods. Comparisons with other algorithms on the benchmark data show that Goldindec has a higher accuracy and computational efficiency, and is hardly affected by great peaks, peak number, and wavenumber. PMID:26037638

  16. Correction of Proton Resonance Frequency Shift Temperature Maps for Magnetic Field Disturbances Caused by Breathing

    NASA Astrophysics Data System (ADS)

    Shmatukha, Andriy V.; Bakker, Chris J. G.

    2006-05-01

    Respiratory Induced Resonance Offset (RIRO) is a periodic disturbance of the magnetic field due to breathing. Such disturbances handicap the accuracy of the Proton Resonance Frequency Shift (PRFS) method of MRI temperature mapping in anatomies situated nearby the lungs and chest wall. In this work, we propose a method capable of minimizing errors caused by RIRO in PRFS temperature maps. In this method, a set of baseline images characterizing RIRO at a variety of respiratory cycle instants is acquired before the thermal treatment starts. During the treatment, the temperature evolution is found from two successive images. Then, the calculated temperature changes are corrected for the additional contribution caused by RIRO using the pre-treatment baseline images acquired at the identical instances of the respiratory cycle. Our method is shown to improve the accuracy and stability of PRFS temperature maps in the presence of RIRO and motion in phantom and volunteer experiments.

  17. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    PubMed Central

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    AIM To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. METHODS Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). RESULTS The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB (P<0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB (P=0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB (P<0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. CONCLUSION Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended. PMID:29062776

  18. Analyte quantification with comprehensive two-dimensional gas chromatography: assessment of methods for baseline correction, peak delineation, and matrix effect elimination for real samples.

    PubMed

    Samanipour, Saer; Dimitriou-Christidis, Petros; Gros, Jonas; Grange, Aureline; Samuel Arey, J

    2015-01-02

    Comprehensive two-dimensional gas chromatography (GC×GC) is used widely to separate and measure organic chemicals in complex mixtures. However, approaches to quantify analytes in real, complex samples have not been critically assessed. We quantified 7 PAHs in a certified diesel fuel using GC×GC coupled to flame ionization detector (FID), and we quantified 11 target chlorinated hydrocarbons in a lake water extract using GC×GC with electron capture detector (μECD), further confirmed qualitatively by GC×GC with electron capture negative chemical ionization time-of-flight mass spectrometer (ENCI-TOFMS). Target analyte peak volumes were determined using several existing baseline correction algorithms and peak delineation algorithms. Analyte quantifications were conducted using external standards and also using standard additions, enabling us to diagnose matrix effects. We then applied several chemometric tests to these data. We find that the choice of baseline correction algorithm and peak delineation algorithm strongly influence the reproducibility of analyte signal, error of the calibration offset, proportionality of integrated signal response, and accuracy of quantifications. Additionally, the choice of baseline correction and the peak delineation algorithm are essential for correctly discriminating analyte signal from unresolved complex mixture signal, and this is the chief consideration for controlling matrix effects during quantification. The diagnostic approaches presented here provide guidance for analyte quantification using GC×GC. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Accurate wavelength measurements of a putative standard for near-infrared diffuse reflection spectrometry.

    PubMed

    Isaksson, Tomas; Yang, Husheng; Kemeny, Gabor J; Jackson, Richard S; Wang, Qian; Alam, M Kathleen; Griffiths, Peter R

    2003-02-01

    The diffuse reflection (DR) spectrum of a sample consisting of a mixture of rare earth oxides and talc was measured at 2 cm-1 resolution, using five different accessories installed on five different Fourier transform near-infrared (FT-NIR) spectrometers from four manufacturers. Peak positions for 37 peaks were determined using two peak-picking algorithms: center-of-mass and polynomial fitting. The wavenumber of the band center reported by either of these techniques was sensitive to the slope of the baseline, and so the baseline of the spectra was corrected using either a polynomial fit or conversion to the second derivative. Significantly different results were obtained with one combination of spectrometer and accessory than the others. Apparently, the beam path through the interferometer and DR accessory was different for this accessory than for any of the other measurements, causing a severe degradation of the resolution. Spectra measured on this instrument were removed as outliers. For measurements made on FT-NIR spectrometers, it is shown that it is important to check the resolution at which the spectrum has been measured using lines in the vibration-rotation spectrum of atmospheric water vapor and to specify the peak-picking and baseline-correction algorithms that are used to process the measured spectra. The variance between the results given by the four different methods of peak-picking and baseline correction was substantially larger than the variance between the remaining five measurements. Certain bands were found to be more suitable than others for use as wavelength standards. A band at 5943.13 cm-1 (1682.62 nm) was found to be the most stable band between the four methods and the six measurements. A band at 5177.04 cm-1 (1931.61 nm) has the highest precision between different measurements when polynomial baseline correction and polynomial peak-picking algorithms are used.

  20. Surface dose measurements with commonly used detectors: a consistent thickness correction method

    PubMed Central

    Higgins, Patrick

    2015-01-01

    The purpose of this study was to review application of a consistent correction method for the solid state detectors, such as thermoluminescent dosimeters (chips (cTLD) and powder (pTLD)), optically stimulated detectors (both closed (OSL) and open (eOSL)), and radiochromic (EBT2) and radiographic (EDR2) films. In addition, to compare measured surface dose using an extrapolation ionization chamber (PTW 30‐360) with other parallel plate chambers RMI‐449 (Attix), Capintec PS‐033, PTW 30‐329 (Markus) and Memorial. Measurements of surface dose for 6 MV photons with parallel plate chambers were used to establish a baseline. cTLD, OSLs, EDR2, and EBT2 measurements were corrected using a method which involved irradiation of three dosimeter stacks, followed by linear extrapolation of individual dosimeter measurements to zero thickness. We determined the magnitude of correction for each detector and compared our results against an alternative correction method based on effective thickness. All uncorrected surface dose measurements exhibited overresponse, compared with the extrapolation chamber data, except for the Attix chamber. The closest match was obtained with the Attix chamber (−0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EBT2 (14%), EDR2 (14.8%), and OSL (26%). Application of published ionization chamber corrections brought all the parallel plate results to within 1% of the extrapolation chamber. The extrapolation method corrected all solid‐state detector results to within 2% of baseline, except the OSLs. Extrapolation of dose using a simple three‐detector stack has been demonstrated to provide thickness corrections for cTLD, eOSLs, EBT2, and EDR2 which can then be used for surface dose measurements. Standard OSLs are not recommended for surface dose measurement. The effective thickness method suffers from the subjectivity inherent in the inclusion of measured percentage depth‐dose curves and is not recommended for these types of measurements. PACS number: 87.56.‐v PMID:26699319

  1. Enhanced GPS-based GRACE baseline determination by using a new strategy for ambiguity resolution and relative phase center variation corrections

    NASA Astrophysics Data System (ADS)

    Gu, Defeng; Ju, Bing; Liu, Junhong; Tu, Jia

    2017-09-01

    Precise relative position determination is a prerequisite for radar interferometry by formation flying satellites. It has been shown that this can be achieved by high-quality, dual-frequency GPS receivers that provide precise carrier-phase observations. The precise baseline determination between satellites flying in formation can significantly improve the accuracy of interferometric products, and has become a research interest. The key technologies of baseline determination using spaceborne dual-frequency GPS for gravity recovery and climate experiment (GRACE) formation are presented, including zero-difference (ZD) reduced dynamic orbit determination, double-difference (DD) reduced dynamic relative orbit determination, integer ambiguity resolution and relative receiver antenna phase center variation (PCV) estimation. We propose an independent baseline determination method based on a new strategy of integer ambiguity resolution and correction of relative receiver antenna PCVs, and implement the method in the NUDTTK software package. The algorithms have been tested using flight data over a period of 120 days from GRACE. With the original strategy of integer ambiguity resolution based on Melbourne-Wübbena (M-W) combinations, the average success rate is 85.6%, and the baseline precision is 1.13 mm. With the new strategy of integer ambiguity resolution based on a priori relative orbit, the average success rate and baseline precision are improved by 5.8% and 0.11 mm respectively. A relative ionosphere-free phase pattern estimation result is given in this study, and with correction of relative receiver antenna PCVs, the baseline precision is further significantly improved by 0.34 mm. For ZD reduced dynamic orbit determination, the orbit precision for each GRACE satellite A or B in three dimensions (3D) is about 2.5 cm compared to Jet Propulsion Laboratory (JPL) post science orbits. For DD reduced dynamic relative orbit determination, the final baseline precision for two GRACE satellites formation is 0.68 mm validated by K-Band Ranging (KBR) observations, and average ambiguity success rate of about 91.4% could be achieved.

  2. Baseline correction combined partial least squares algorithm and its application in on-line Fourier transform infrared quantitative analysis.

    PubMed

    Peng, Jiangtao; Peng, Silong; Xie, Qiong; Wei, Jiping

    2011-04-01

    In order to eliminate the lower order polynomial interferences, a new quantitative calibration algorithm "Baseline Correction Combined Partial Least Squares (BCC-PLS)", which combines baseline correction and conventional PLS, is proposed. By embedding baseline correction constraints into PLS weights selection, the proposed calibration algorithm overcomes the uncertainty in baseline correction and can meet the requirement of on-line attenuated total reflectance Fourier transform infrared (ATR-FTIR) quantitative analysis. The effectiveness of the algorithm is evaluated by the analysis of glucose and marzipan ATR-FTIR spectra. BCC-PLS algorithm shows improved prediction performance over PLS. The root mean square error of cross-validation (RMSECV) on marzipan spectra for the prediction of the moisture is found to be 0.53%, w/w (range 7-19%). The sugar content is predicted with a RMSECV of 2.04%, w/w (range 33-68%). Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Charactering baseline shift with 4th polynomial function for portable biomedical near-infrared spectroscopy device

    NASA Astrophysics Data System (ADS)

    Zhao, Ke; Ji, Yaoyao; Pan, Boan; Li, Ting

    2018-02-01

    The continuous-wave Near-infrared spectroscopy (NIRS) devices have been highlighted for its clinical and health care applications in noninvasive hemodynamic measurements. The baseline shift of the deviation measurement attracts lots of attentions for its clinical importance. Nonetheless current published methods have low reliability or high variability. In this study, we found a perfect polynomial fitting function for baseline removal, using NIRS. Unlike previous studies on baseline correction for near-infrared spectroscopy evaluation of non-hemodynamic particles, we focused on baseline fitting and corresponding correction method for NIRS and found that the polynomial fitting function at 4th order is greater than the function at 2nd order reported in previous research. Through experimental tests of hemodynamic parameters of the solid phantom, we compared the fitting effect between the 4th order polynomial and the 2nd order polynomial, by recording and analyzing the R values and the SSE (the sum of squares due to error) values. The R values of the 4th order polynomial function fitting are all higher than 0.99, which are significantly higher than the corresponding ones of 2nd order, while the SSE values of the 4th order are significantly smaller than the corresponding ones of the 2nd order. By using the high-reliable and low-variable 4th order polynomial fitting function, we are able to remove the baseline online to obtain more accurate NIRS measurements.

  4. Artifact Correction in Temperature-Dependent Attenuated Total Reflection Infrared (ATR-IR) Spectra.

    PubMed

    Sobieski, Brian; Chase, Bruce; Noda, Isao; Rabolt, John

    2017-08-01

    A spectral processing method was developed and tested for analyzing temperature-dependent attenuated total reflection infrared (ATR-IR) spectra of aliphatic polyesters. Spectra of a bio-based, biodegradable polymer, 3.9 mol% 3HHx poly[(R)-3-hydroxybutyrate- co-(R)-3-hydroxyhexanoate] (PHBHx), were analyzed and corrected prior to analysis using two-dimensional correlation spectroscopy (2D-COS). Removal of the temperature variation of diamond absorbance, correction of the baseline, ATR correction, and appropriate normalization were key to generating more reliable data. Both the processing steps and order were important. A comparison to differential scanning calorimetry (DSC) analysis indicated that the normalization method should be chosen with caution to avoid unintentional trends and distortions of the crystalline sensitive bands.

  5. Geodesy by radio interferometry - Water vapor radiometry for estimation of the wet delay

    NASA Technical Reports Server (NTRS)

    Elgered, G.; Davis, J. L.; Herring, T. A.; Shapiro, I. I.

    1991-01-01

    An important source of error in VLBI estimates of baseline length is unmodeled variations of the refractivity of the neutral atmosphere along the propagation path of the radio signals. This paper presents and discusses the method of using data from a water vapor radiomete (WVR) to correct for the propagation delay caused by atmospheric water vapor, the major cause of these variations. Data from different WVRs are compared with estimated propagation delays obtained by Kalman filtering of the VLBI data themselves. The consequences of using either WVR data or Kalman filtering to correct for atmospheric propagation delay at the Onsala VLBI site are investigated by studying the repeatability of estimated baseline lengths from Onsala to several other sites. The repeatability obtained for baseline length estimates shows that the methods of water vapor radiometry and Kalman filtering offer comparable accuracies when applied to VLBI observations obtained in the climate of the Swedish west coast. For the most frequently measured baseline in this study, the use of WVR data yielded a 13 percent smaller weighted-root-mean-square (WRMS) scatter of the baseline length estimates compared to the use of a Kalman filter. It is also clear that the 'best' minimum elevationi angle for VLBI observations depends on the accuracy of the determinations of the total propagation delay to be used, since the error in this delay increases with increasing air mass.

  6. Extracting Baseline Electricity Usage Using Gradient Tree Boosting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Taehoon; Lee, Dongeun; Choi, Jaesik

    To understand how specific interventions affect a process observed over time, we need to control for the other factors that influence outcomes. Such a model that captures all factors other than the one of interest is generally known as a baseline. In our study of how different pricing schemes affect residential electricity consumption, the baseline would need to capture the impact of outdoor temperature along with many other factors. In this work, we examine a number of different data mining techniques and demonstrate Gradient Tree Boosting (GTB) to be an effective method to build the baseline. We train GTB onmore » data prior to the introduction of new pricing schemes, and apply the known temperature following the introduction of new pricing schemes to predict electricity usage with the expected temperature correction. Our experiments and analyses show that the baseline models generated by GTB capture the core characteristics over the two years with the new pricing schemes. In contrast to the majority of regression based techniques which fail to capture the lag between the peak of daily temperature and the peak of electricity usage, the GTB generated baselines are able to correctly capture the delay between the temperature peak and the electricity peak. Furthermore, subtracting this temperature-adjusted baseline from the observed electricity usage, we find that the resulting values are more amenable to interpretation, which demonstrates that the temperature-adjusted baseline is indeed effective.« less

  7. A Fully Customized Baseline Removal Framework for Spectroscopic Applications.

    PubMed

    Giguere, Stephen; Boucher, Thomas; Carey, C J; Mahadevan, Sridhar; Dyar, M Darby

    2017-07-01

    The task of proper baseline or continuum removal is common to nearly all types of spectroscopy. Its goal is to remove any portion of a signal that is irrelevant to features of interest while preserving any predictive information. Despite the importance of baseline removal, median or guessed default parameters are commonly employed, often using commercially available software supplied with instruments. Several published baseline removal algorithms have been shown to be useful for particular spectroscopic applications but their generalizability is ambiguous. The new Custom Baseline Removal (Custom BLR) method presented here generalizes the problem of baseline removal by combining operations from previously proposed methods to synthesize new correction algorithms. It creates novel methods for each technique, application, and training set, discovering new algorithms that maximize the predictive accuracy of the resulting spectroscopic models. In most cases, these learned methods either match or improve on the performance of the best alternative. Examples of these advantages are shown for three different scenarios: quantification of components in near-infrared spectra of corn and laser-induced breakdown spectroscopy data of rocks, and classification/matching of minerals using Raman spectroscopy. Software to implement this optimization is available from the authors. By removing subjectivity from this commonly encountered task, Custom BLR is a significant step toward completely automatic and general baseline removal in spectroscopic and other applications.

  8. The Effect of Bifocal Add on Accommodative Lag in Myopic Children with High Accommodative Lag

    PubMed Central

    Mutti, Donald O.; Zadnik, Karla

    2010-01-01

    Purpose. To determine the effect of a bifocal add and manifest correction on accommodative lag in myopic children with high accommodative lag, who have been reported to have the greatest reduction in myopia progression with progressive addition lenses (PALs). Methods. Monocular accommodative lag to a 4-D Badal stimulus was measured on two occasions 6 months apart in 83 children (mean ± SD age, 9.9 ± 1.3 years) with high lag randomized to wearing single-vision lenses (SVLs) or PALs. Accommodative lag was measured with the following corrections: habitual, manifest, manifest with +2.00-D add, and habitual with +2.00-D add (6-month visit only). Results. At baseline, accommodative lag was higher (1.72 ± 0.37 D; mean ± SD) when measured with manifest correction than with habitual correction (1.51 ± 0.50; P < 0.05). This higher lag with manifest correction correlated with a larger amount of habitual undercorrection at baseline (r = −0.29, P = 0.009). A +2.00-D add over the manifest correction reduced lag by 0.45 ± 0.34 D at baseline and 0.33 ± 0.38 D at the 6-month visit. Lag results at 6 months were not different between PAL and SVL wearers (P = 0.92). Conclusions. A +2.00-D bifocal add did not eliminate accommodative lag and reduced lag by less than 25% of the bifocal power, indicating that children mainly responded to a bifocal by decreasing accommodation. If myopic progression is substantial, measuring lag with full correction can overestimate the hyperopic retinal blur that a child most recently experienced. (ClinicalTrials.gov number, NCT00335049.) PMID:20688729

  9. Management of the baseline shift using a new and simple method for respiratory-gated radiation therapy: Detectability and effectiveness of a flexible monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tachibana, Hidenobu; Kitamura, Nozomi; Ito, Yasushi

    2011-07-15

    Purpose: In respiratory-gated radiation therapy, a baseline shift decreases the accuracy of target coverage and organs at risk (OAR) sparing. The effectiveness of audio-feedback and audio-visual feedback in correcting the baseline shift in the breathing pattern of the patient has been demonstrated previously. However, the baseline shift derived from the intrafraction motion of the patient's body cannot be corrected by these methods. In the present study, the authors designed and developed a simple and flexible system. Methods: The system consisted of a web camera and a computer running our in-house software. The in-house software was adapted to template matching andmore » also to no preimage processing. The system was capable of monitoring the baseline shift in the intrafraction motion of the patient's body. Another marker box was used to monitor the baseline shift due to the flexible setups required of a marker box for gated signals. The system accuracy was evaluated by employing a respiratory motion phantom and was found to be within AAPM Task Group 142 tolerance (positional accuracy <2 mm and temporal accuracy <100 ms) for respiratory-gated radiation therapy. Additionally, the effectiveness of this flexible and independent system in gated treatment was investigated in healthy volunteers, in terms of the results from the differences in the baseline shift detectable between the marker positions, which the authors evaluated statistically. Results: The movement of the marker on the sternum [1.599 {+-} 0.622 mm (1 SD)] was substantially decreased as compared with the abdomen [6.547 {+-} 0.962 mm (1 SD)]. Additionally, in all of the volunteers, the baseline shifts for the sternum [-0.136 {+-} 0.868 (2 SD)] were in better agreement with the nominal baseline shifts than was the case for the abdomen [-0.722 {+-} 1.56 mm (2 SD)]. The baseline shifts could be accurately measured and detected using the monitoring system, which could acquire the movement of the marker on the sternum. The baseline shift-monitoring system with the displacement-based methods for highly accurate respiratory-gated treatments should be used to make most of the displacement-based gating methods. Conclusions: The advent of intensity modulated radiation therapy and volumetric modulated radiation therapy facilitates margin reduction for the planning target volumes and the OARs, but highly accurate irradiation is needed to achieve target coverage and OAR sparing with a small margin. The baseline shifts can affect treatment not only with the respiratory gating system but also without the system. Our system can manage the baseline shift and also enables treatment irradiation to be undertaken with high accuracy.« less

  10. Action Research of an Error Self-Correction Intervention: Examining the Effects on the Spelling Accuracy Behaviors of Fifth-Grade Students Identified as At-Risk

    ERIC Educational Resources Information Center

    Turner, Jill; Rafferty, Lisa A.; Sullivan, Ray; Blake, Amy

    2017-01-01

    In this action research case study, the researchers used a multiple baseline across two student pairs design to investigate the effects of the error self-correction method on the spelling accuracy behaviors for four fifth-grade students who were identified as being at risk for learning disabilities. The dependent variable was the participants'…

  11. Long-term follow-up of echolalia and question answering.

    PubMed

    Foxx, R M; Faw, G D

    1990-01-01

    A long-term follow-up of echolalia and correct question answering was conducted for 6 subjects from three previously published studies. The follow-up periods ranged from 26 to 57 months. In a training site follow-up, subjects were exposed to baseline/posttraining conditions in which the original trainer and/or a novel person(s) presented trained and untrained questions. Four subjects displayed echolalia below baseline levels, and another did so in some assessments. Overall, echolalia was lower than in baseline in 80.6% of the follow-ups. Five subjects displayed correct responding above baseline levels. No clear differences were noted in correct responding or echolalia between the trainer and novel-person presentations or between trained and untrained questions. In a follow-up in a natural environment conducted by a novel person, lower than baseline levels of echolalia were displayed by 3 subjects; 2 subjects displayed lower than baseline levels in some assessments. Two subjects consistently displayed correct responding above baseline, and 3 did so occasionally. Issues related to the study of maintenance are discussed.

  12. Long-term follow-up of echolalia and question answering.

    PubMed Central

    Foxx, R M; Faw, G D

    1990-01-01

    A long-term follow-up of echolalia and correct question answering was conducted for 6 subjects from three previously published studies. The follow-up periods ranged from 26 to 57 months. In a training site follow-up, subjects were exposed to baseline/posttraining conditions in which the original trainer and/or a novel person(s) presented trained and untrained questions. Four subjects displayed echolalia below baseline levels, and another did so in some assessments. Overall, echolalia was lower than in baseline in 80.6% of the follow-ups. Five subjects displayed correct responding above baseline levels. No clear differences were noted in correct responding or echolalia between the trainer and novel-person presentations or between trained and untrained questions. In a follow-up in a natural environment conducted by a novel person, lower than baseline levels of echolalia were displayed by 3 subjects; 2 subjects displayed lower than baseline levels in some assessments. Two subjects consistently displayed correct responding above baseline, and 3 did so occasionally. Issues related to the study of maintenance are discussed. PMID:2249974

  13. New baseline correction algorithm for text-line recognition with bidirectional recurrent neural networks

    NASA Astrophysics Data System (ADS)

    Morillot, Olivier; Likforman-Sulem, Laurence; Grosicki, Emmanuèle

    2013-04-01

    Many preprocessing techniques have been proposed for isolated word recognition. However, recently, recognition systems have dealt with text blocks and their compound text lines. In this paper, we propose a new preprocessing approach to efficiently correct baseline skew and fluctuations. Our approach is based on a sliding window within which the vertical position of the baseline is estimated. Segmentation of text lines into subparts is, thus, avoided. Experiments conducted on a large publicly available database (Rimes), with a BLSTM (bidirectional long short-term memory) recurrent neural network recognition system, show that our baseline correction approach highly improves performance.

  14. An online spaced-education game to teach and assess residents: a multi-institutional prospective trial.

    PubMed

    Kerfoot, B Price; Baker, Harley

    2012-03-01

    While games are frequently used in resident education, there is little evidence supporting their efficacy. We investigated whether a spaced-education (SE) game can be both a reliable and valid method of assessing residents' knowledge and an effective means of teaching core content. The SE game consisted of 100 validated multiple-choice questions and explanations on core urology content. Residents were sent 2 questions each day via email. Adaptive game mechanics re-sent the questions in 2 or 6 weeks if answered incorrectly and correctly, respectively. Questions expired if not answered on time (appointment dynamic). Residents retired questions by answering each correctly twice in a row (progression dynamic). Competition was fostered by posting relative performance among residents. Main outcomes measures were baseline scores (percentage of questions answered correctly on initial presentation) and completion scores (percentage of questions retired). Nine hundred thirty-one US and Canadian residents enrolled in the 45-week trial. Cronbach alpha reliability for the SE baseline scores was 0.87. Baseline scores (median 62%, interquartile range [IQR] 17%) correlated with scores on the 2008 American Urological Association in-service examination (ISE08), 2009 American Board of Urology qualifying examination (QE09), and ISE09 (r = 0.76, 0.46, and 0.64, respectively; all p < 0.001). Baseline scores varied by sex, country, medical degree, and year of training (all p ≤ 0.001). Completion scores (median 100%, IQR 2%) correlated with ISE08 and ISE09 scores (r = 0.35, p < 0.001 for both). Seventy-two percent of enrollees (667 of 931) requested to participate in future SE games. An SE game is a reliable and valid means to assess residents' knowledge and is a well-accepted method by which residents can master core content. Published by Elsevier Inc.

  15. Time-lapse processing of 2D seismic profiles with testing of static correction methods at the CO2 injection site Ketzin (Germany)

    NASA Astrophysics Data System (ADS)

    Bergmann, Peter; Yang, Can; Lüth, Stefan; Juhlin, Christopher; Cosma, Calin

    2011-09-01

    The Ketzin project provides an experimental pilot test site for the geological storage of CO2. Seismic monitoring of the Ketzin site comprises 2D and 3D time-lapse experiments with baseline experiments in 2005. The first repeat 2D survey was acquired in 2009 after 22 kt of CO2 had been injected into the Stuttgart Formation at approximately 630 m depth. Main objectives of the 2D seismic surveys were the imaging of geological structures, detection of injected CO2, and comparison with the 3D surveys. Time-lapse processing highlighted the importance of detailed static corrections to account for travel time delays, which are attributed to different near-surface velocities during the survey periods. Compensation for these delays has been performed using both pre-stack static corrections and post-stack static corrections. The pre-stack method decomposes the travel time delays of baseline and repeat datasets in a surface consistent manner, while the latter cross-aligns baseline and repeat stacked sections along a reference horizon. Application of the static corrections improves the S/N ratio of the time-lapse sections significantly. Based on our results, it is recommended to apply a combination of both corrections when time-lapse processing faces considerable near-surface velocity changes. Processing of the datasets demonstrates that the decomposed solution of the pre-stack static corrections can be used for interpretation of changes in near-surface velocities. In particular, the long-wavelength part of the solution indicates an increase in soil moisture or a shallower groundwater table in the repeat survey. Comparison with the processing results of 2D and 3D surveys shows that both image the subsurface, but with local variations which are mainly associated to differences in the acquisition geometry and source types used. Interpretation of baseline and repeat stacks shows that no CO2 related time-lapse signature is observable where the 2D lines allow monitoring of the reservoir. This finding is consistent with the time-lapse results of the 3D surveys, which show an increase in reflection amplitude centered around the injection well. To further investigate any potential CO2 signature, an amplitude versus offset (AVO) analysis was performed. The time-lapse analysis of the AVO does not indicate the presence of CO2, as expected, but shows signs of a pressure response in the repeat data.

  16. On the possibility of producing definitive magnetic observatory data within less than one year

    NASA Astrophysics Data System (ADS)

    Mandić, Igor; Korte, Monika

    2017-04-01

    Geomagnetic observatory data are fundamental in geomagnetic field studies and are widely used in other applications. Often they are combined with satellite and ground survey data. Unfortunately, the observatory definitive data are only available with a time lag ranging from several months up to more than a year. The reason for this lag is the annual production of the final calibration values, i.e. baselines that are used to correct preliminary data from continuously recording magnetometers. In this paper, we will show that the preparation of definitive geomagnetic data is possible within a calendar year and presents an original method for prompt and automatic estimation of the observatory baselines. The new baselines, obtained in a mostly automatic manner, are compared with the baselines reported on INTERMAGNET DVDs for the 2009-2011 period. The high quality of the baselines obtained by the proposed method indicates its suitability for data processing in fully automatic observatories when automated absolute instruments will be deployed at remote sites.

  17. Geodesy by radio interferometry: Water vapor radiometry for estimation of the wet delay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elgered, G.; Davis, J.L.; Herring, T.A.

    1991-04-10

    An important source of error in very-long-baseline interferometry (VLBI) estimates of baseline length is unmodeled variations of the refractivity of the neutral atmosphere along the propagation path of the radio signals. The authors present and discuss the method of using data from a water vapor readiometer (WVR) to correct for the propagation delay caused by atmospheric water vapor, the major cause of these variations. Data from different WVRs are compared with estimated propagation delays obtained by Kalman filtering of the VLBI data themselves. The consequences of using either WVR data of Kalman filtering to correct for atmospheric propagation delay atmore » the Onsala VLBI site are investigated by studying the repeatability of estimated baseline lengths from Onsala to several other sites. The lengths of the baselines range from 919 to 7,941 km. The repeatability obtained for baseline length estimates shows that the methods of water vapor radiometry and Kalman filtering offer comparable accuracies when applied to VLBI observations obtained in the climate of the Swedish west coast. The use of WVR data yielded a 13% smaller weighted-root-mean-square (WRMS) scatter of the baseline length estimates compared to the use of a Kalman filter. It is also clear that the best minimum elevation angle for VLBI observations depends on the accuracy of the determinations of the total propagation delay to be used, since the error in this delay increases with increasing air mass. For use of WVR data along with accurate determinations of total surface pressure, the best minimum is about 20{degrees}; for use of a model for the wet delay based on the humidity and temperature at the ground, the best minimum is about 35{degrees}.« less

  18. Rehabilitation in semantic dementia: Study of effectiveness of lexical reacquisition in three patients

    PubMed Central

    Senaha, Mirna Lie Hosogi; Brucki, Sonia Maria Dozzi; Nitrini, Ricardo

    2010-01-01

    Although language rehabilitation in patients with primary progressive aphasia (PPA) is recommended, rehabilitation studies in this clinical syndrome are scarce. Specifically, in relation to semantic dementia (SD), few studies have shown the possibility of lexical relearning. Objective To analyze the effectiveness of rehabilitation for lexical reacquisition in SD. Methods Three SD patients were submitted to training for lexical reacquisition based on principles of errorless learning. Comparisons between naming performance of treated items (pre and post-training) and non-treated items of the Boston Naming Test (BNT) were made. Results All patients improved their performance in naming treated words after intervention. However, decline in performance in naming of non-treated items was observed. Case 1 named zero items at baseline while her performance post-training was 29.4% correct responses without cueing, and 90.7% correct with and without cueing. Case 2 named 6.9% of items correctly at baseline and his performance in post-training was 52.9% without cueing and 87.3%, with and without cueing. Case 3 named zero items at baseline and his performance in post-training was 100% correct responses without cueing. Considering the performance in naming the non-treated items of the BNT, the percentages of correct responses in the first evaluation and in the re-evaluation, respectively were: 16.7% and 8.3% (case 1; 14 month-interval); 26.7% and 11.6% (case 2; 18 month-interval) and 11.6% and 8.3% (case 3; 6 month-interval). Conclusions The reacquisition of lost vocabulary may be possible in SD despite progressive semantic deterioration. PMID:29213703

  19. The Use of Correctional “NO!” Approach to Reduce Destructive Behavior on Autism Student of CANDA Educational Institution in Surakarta

    NASA Astrophysics Data System (ADS)

    Anggraini, N.

    2017-02-01

    This research aims to reduce the destructive behavior such as throwing the learning materials on autism student by using correctional “NO!” approach in CANDA educational institution Surakarta. This research uses Single Subject Research (SSR) method with A-B design, it is baseline and intervention. Subject of this research is one autism student of CANDA educational institution named G.A.P. Data were collected through recording in direct observation in the form of recording events at the time of implementation baseline and intervention. Data were analyzed by simple descriptive statistical analysis and is displayed in graphical form. Based on the result of data analysis, it could be concluded that destructive behavior such as throwing the learning material on autism student was significantly reduced after given an intervention. Based on the research results, using correctional “NO!” approach can be used by teacher or therapist to reduce the destructive behavior on autism student.

  20. The Steroids for Corneal Ulcers Trial

    PubMed Central

    Srinivasan, Muthiah; Mascarenhas, Jeena; Rajaraman, Revathi; Ravindran, Meenakshi; Lalitha, Prajna; Glidden, David V.; Ray, Kathryn J.; Hong, Kevin C.; Oldenburg, Catherine E.; Lee, Salena M.; Zegans, Michael E.; McLeod, Stephen D.; Lietman, Thomas M.; Acharya, Nisha R.

    2013-01-01

    Objectives To provide comprehensive trial methods and baseline data for the Steroids for Corneal Ulcers Trial and to present epidemiological characteristics such as risk factors, causative organisms, and ulcer severity. Methods Baseline data from a 1:1 randomized, placebo-controlled, double-masked clinical trial comparing prednisolone phosphate, 1%, with placebo as adjunctive therapy for the treatment of bacterial corneal ulcers. Eligible patients had a culture-positive bacterial corneal ulcer and had been taking moxifloxacin for 48 hours. The primary outcome for the trial is best spectacle-corrected visual acuity at 3 months from enrollment. This report provides comprehensive baseline data, including best spectacle-corrected visual acuity, infiltrate size, microbio-logical results, and patient demographics, for patients enrolled in the trial. Results Of 500 patients enrolled, 97% were in India. Two hundred twenty patients (44%) were agricultural workers. Median baseline visual acuity was 0.84 logMAR (Snellen, 20/125) (interquartile range, 0.36-1.7; Snellen, 20/50 to counting fingers). Baseline visual acuity was not significantly different between the United States and India. Ulcers in India had larger infiltrate/scar sizes (P=.04) and deeper infiltrates (P=.04) and were more likely to be localized centrally (P=.002) than ulcers enrolled in the United States. Gram-positive bacteria were the most common organisms isolated from the ulcers (n=366, 72%). Conclusions The Steroids for Corneal Ulcers Trial will compare the use of a topical corticosteroid with placebo as adjunctive therapy for bacterial corneal ulcers. Patients enrolled in this trial had diverse ulcer severity and on average significantly reduced visual acuity at presentation. PMID:21987581

  1. ALMA long baseline phase calibration using phase referencing

    NASA Astrophysics Data System (ADS)

    Asaki, Yoshiharu; Matsushita, Satoki; Fomalont, Edward B.; Corder, Stuartt A.; Nyman, Lars-Åke; Dent, William R. F.; Philips, Neil M.; Hirota, Akihiko; Takahashi, Satoko; Vila-Vilaro, Baltasar; Nikolic, Bojan; Hunter, Todd R.; Remijan, Anthony; Vlahakis, Catherine

    2016-08-01

    The Atacama Large Millimeter/submillimeter Array (ALMA) is the world's largest millimeter/submillimeter telescope and provides unprecedented sensitivities and spatial resolutions. To achieve the highest imaging capabilities, interferometric phase calibration for the long baselines is one of the most important subjects: The longer the baselines, the worse the phase stability becomes because of turbulent motions of the Earth's atmosphere, especially, the water vapor in the troposphere. To overcome this subject, ALMA adopts a phase correction scheme using a Water Vapor Radiometer (WVR) to estimate the amount of water vapor content along the antenna line of sight. An additional technique is phase referencing, in which a science target and a nearby calibrator are observed by turn by quickly changing the antenna pointing. We conducted feasibility studies of the hybrid technique with the WVR phase correction and the antenna Fast Switching (FS) phase referencing (WVR+FS phase correction) for the ALMA 16 km longest baselines in cases that (1) the same observing frequency both for a target and calibrator is used, and (2) higher and lower frequencies for a target and calibrator, respectively, with a typical switching cycle time of 20 s. It was found that the phase correction performance of the hybrid technique is promising where a nearby calibrator is located within roughly 3◦ from a science target, and that the phase correction with 20 s switching cycle time significantly improves the performance with the above separation angle criterion comparing to the 120 s switching cycle time. The currently trial phase calibration method shows the same performance independent of the observing frequencies. This result is especially important for the higher frequency observations because it becomes difficult to find a bright calibrator close to an arbitrary sky position. In the series of our experiments, it is also found that phase errors affecting the image quality come from not only the water vapor content in the lower troposphere but also a large structure of the atmosphere with a typical cell scale of a few tens of kilometers.

  2. Intraoperative laser speckle contrast imaging with retrospective motion correction for quantitative assessment of cerebral blood flow

    PubMed Central

    Richards, Lisa M.; Towle, Erica L.; Fox, Douglas J.; Dunn, Andrew K.

    2014-01-01

    Abstract. Although multiple intraoperative cerebral blood flow (CBF) monitoring techniques are currently available, a quantitative method that allows for continuous monitoring and that can be easily integrated into the surgical workflow is still needed. Laser speckle contrast imaging (LSCI) is an optical imaging technique with a high spatiotemporal resolution that has been recently demonstrated as feasible and effective for intraoperative monitoring of CBF during neurosurgical procedures. This study demonstrates the impact of retrospective motion correction on the quantitative analysis of intraoperatively acquired LSCI images. LSCI images were acquired through a surgical microscope during brain tumor resection procedures from 10 patients under baseline conditions and after a cortical stimulation in three of those patients. The patient’s electrocardiogram (ECG) was recorded during acquisition for postprocess correction of pulsatile artifacts. Automatic image registration was retrospectively performed to correct for tissue motion artifacts, and the performance of rigid and nonrigid transformations was compared. In baseline cases, the original images had 25%±27% noise across 16 regions of interest (ROIs). ECG filtering moderately reduced the noise to 20%±21%, while image registration resulted in a further noise reduction of 15%±4%. Combined ECG filtering and image registration significantly reduced the noise to 6.2%±2.6% (p<0.05). Using the combined motion correction, accuracy and sensitivity to small changes in CBF were improved in cortical stimulation cases. There was also excellent agreement between rigid and nonrigid registration methods (15/16 ROIs with <3% difference). Results from this study demonstrate the importance of motion correction for improved visualization of CBF changes in clinical LSCI images. PMID:26157974

  3. Application of point-to-point matching algorithms for background correction in on-line liquid chromatography-Fourier transform infrared spectrometry (LC-FTIR).

    PubMed

    Kuligowski, J; Quintás, G; Garrigues, S; de la Guardia, M

    2010-03-15

    A new background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry has been developed. It is based on the use of a point-to-point matching algorithm that compares the absorption spectra of the sample data set with those of a previously recorded reference data set in order to select an appropriate reference spectrum. The spectral range used for the point-to-point comparison is selected with minimal user-interaction, thus facilitating considerably the application of the whole method. The background correction method has been successfully tested on a chromatographic separation of four nitrophenols running acetonitrile (0.08%, v/v TFA):water (0.08%, v/v TFA) gradients with compositions ranging from 35 to 85% (v/v) acetonitrile, giving accurate results for both, baseline resolved and overlapped peaks. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  4. Authentication of organically and conventionally grown basils by gas chromatograpy/mass spectrometry chemical profiles

    USDA-ARS?s Scientific Manuscript database

    Basil plants cultivated by organic and conventional farming practices were differentiated using gas chromatography/mass spectrometry (GC/MS) and chemometric methods. The two-way GC/MS data sets were baseline-corrected and retention time-aligned prior to data processing. Two self-devised fuzzy clas...

  5. [Discussion of scattering in THz time domain spectrum tests].

    PubMed

    Yan, Fang; Zhang, Zhao-hui; Zhao, Xiao-yan; Su, Hai-xia; Li, Zhi; Zhang, Han

    2014-06-01

    Using THz-TDS to extract the absorption spectrum of a sample is an important branch of various THz applications. Basically, we believe that the THz radiation scatters from sample particles, leading to an obvious baseline increasing with frequencies in its absorption spectrum. The baseline will affect the measurement accuracy due to ambiguous height and pattern of the spectrum. The authors should try to remove the baseline, and eliminate the effects of scattering. In the present paper, we investigated the causes of baselines, reviewed some of scatter mitigating methods and summarized some of research aspects in the future. In order to validate the correctness of these methods, we designed a series of experiments to compare the computational accuracy of molar concentration. The result indicated that the computational accuracy of molar concentration can be improved, which can be the basis of quantitative analysis in further researches. Finally, with comprehensive experimental results, we presented further research directions on THz absorption spectrum that is needed for the removal of scattering effects.

  6. Interference correction by extracting the information of interference dominant regions: Application to near-infrared spectra

    NASA Astrophysics Data System (ADS)

    Bi, Yiming; Tang, Liang; Shan, Peng; Xie, Qiong; Hu, Yong; Peng, Silong; Tan, Jie; Li, Changwen

    2014-08-01

    Interference such as baseline drift and light scattering can degrade the model predictability in multivariate analysis of near-infrared (NIR) spectra. Usually interference can be represented by an additive and a multiplicative factor. In order to eliminate these interferences, correction parameters are needed to be estimated from spectra. However, the spectra are often mixed of physical light scattering effects and chemical light absorbance effects, making it difficult for parameter estimation. Herein, a novel algorithm was proposed to find a spectral region automatically that the interesting chemical absorbance and noise are low, that is, finding an interference dominant region (IDR). Based on the definition of IDR, a two-step method was proposed to find the optimal IDR and the corresponding correction parameters estimated from IDR. Finally, the correction was performed to the full spectral range using previously obtained parameters for the calibration set and test set, respectively. The method can be applied to multi target systems with one IDR suitable for all targeted analytes. Tested on two benchmark data sets of near-infrared spectra, the performance of the proposed method provided considerable improvement compared with full spectral estimation methods and comparable with other state-of-art methods.

  7. Minimal entropy reconstructions of thermal images for emissivity correction

    NASA Astrophysics Data System (ADS)

    Allred, Lloyd G.

    1999-03-01

    Low emissivity with corresponding low thermal emission is a problem which has long afflicted infrared thermography. The problem is aggravated by reflected thermal energy which increases as the emissivity decreases, thus reducing the net signal-to-noise ratio, which degrades the resulting temperature reconstructions. Additional errors are introduced from the traditional emissivity-correction approaches, wherein one attempts to correct for emissivity either using thermocouples or using one or more baseline images, collected at known temperatures. These corrections are numerically equivalent to image differencing. Errors in the baseline images are therefore additive, causing the resulting measurement error to either double or triple. The practical application of thermal imagery usually entails coating the objective surface to increase the emissivity to a uniform and repeatable value. While the author recommends that the thermographer still adhere to this practice, he has devised a minimal entropy reconstructions which not only correct for emissivity variations, but also corrects for variations in sensor response, using the baseline images at known temperatures to correct for these values. The minimal energy reconstruction is actually based on a modified Hopfield neural network which finds the resulting image which best explains the observed data and baseline data, having minimal entropy change between adjacent pixels. The autocorrelation of temperatures between adjacent pixels is a feature of most close-up thermal images. A surprising result from transient heating data indicates that the resulting corrected thermal images have less measurement error and are closer to the situational truth than the original data.

  8. [Correction of respiratory movement using ultrasound for cardiac nuclear medicine examinations: fundamental study using an X-ray TV machine].

    PubMed

    Yoda, Kazushige; Umeda, Tokuo; Hasegawa, Tomoyuki

    2003-11-01

    Organ movements that occur naturally as a result of vital functions such as respiration and heartbeat cause deterioration of image quality in nuclear medicine imaging. Among these movements, respiration has a large effect, but there has been no practical method of correcting for this. In the present study, we examined a method of correction that uses ultrasound images to correct baseline shifts caused by respiration in cardiac nuclear medicine examinations. To evaluate the validity of this method, simulation studies were conducted with an X-ray TV machine instead of a nuclear medicine scanner. The X-ray TV images and ultrasound images were recorded as digital movies and processed with public domain software (Scion Image). Organ movements were detected in the ultrasound images of the subcostal four-chamber view mode using slit regions of interest and were measured on a two-dimensional image coordinate. Then translational shifts were applied to the X-ray TV images to correct these movements by using macro-functions of the software. As a result, respiratory movements of about 20.1 mm were successfully reduced to less than 2.6 mm. We conclude that this correction technique is potentially useful in nuclear medicine cardiology.

  9. Bayesian semi-parametric analysis of Poisson change-point regression models: application to policy making in Cali, Colombia.

    PubMed

    Park, Taeyoung; Krafty, Robert T; Sánchez, Alvaro I

    2012-07-27

    A Poisson regression model with an offset assumes a constant baseline rate after accounting for measured covariates, which may lead to biased estimates of coefficients in an inhomogeneous Poisson process. To correctly estimate the effect of time-dependent covariates, we propose a Poisson change-point regression model with an offset that allows a time-varying baseline rate. When the nonconstant pattern of a log baseline rate is modeled with a nonparametric step function, the resulting semi-parametric model involves a model component of varying dimension and thus requires a sophisticated varying-dimensional inference to obtain correct estimates of model parameters of fixed dimension. To fit the proposed varying-dimensional model, we devise a state-of-the-art MCMC-type algorithm based on partial collapse. The proposed model and methods are used to investigate an association between daily homicide rates in Cali, Colombia and policies that restrict the hours during which the legal sale of alcoholic beverages is permitted. While simultaneously identifying the latent changes in the baseline homicide rate which correspond to the incidence of sociopolitical events, we explore the effect of policies governing the sale of alcohol on homicide rates and seek a policy that balances the economic and cultural dependencies on alcohol sales to the health of the public.

  10. On the Adaptation of Pelvic Motion by Applying 3-dimensional Guidance Forces Using TPAD.

    PubMed

    Kang, Jiyeon; Vashista, Vineet; Agrawal, Sunil K

    2017-09-01

    Pelvic movement is important to human locomotion as the center of mass is located near the center of pelvis. Lateral pelvic motion plays a crucial role to shift the center of mass on the stance leg, while swinging the other leg and keeping the body balanced. In addition, vertical pelvic movement helps to reduce metabolic energy expenditure by exchanging potential and kinetic energy during the gait cycle. However, patient groups with cerebral palsy or stroke have excessive pelvic motion that leads to high energy expenditure. In addition, they have higher chances of falls as the center ofmass could deviate outside the base of support. In this paper, a novel control method is suggested using tethered pelvic assist device (TPAD) to teach subjects to walk with a specified target pelvic trajectory while walking on a treadmill. In this method, a force field is applied to the pelvis to guide it to move on a target trajectory and correctional forces are applied, if the pelvis motion has excessive deviations from the target trajectory. Three different experimentswith healthy subjects were conducted to teach them to walk on a new target pelvic trajectory with the presented control method. For all three experiments, the baseline trajectory of the pelvis was experimentally determined for each participating subject. To design a target pelvic trajectory which is different from the baseline, Experiment I scaled up the lateral component of the baseline pelvic trajectory, while Experiment II scaled down the lateral component of the baseline trajectory. For both Experiments I and II, the controller generated a 2-D force field in the transverse plane to provide the guidance force. In this paper, seven subjects were recruited for each experiment who walked on the treadmill with suggested control methods and visual feedback of their pelvic trajectory. The results show that the subjects were able to learn the target pelvic trajectory in each experiment and also retained the training effects after the completion of the experiment. In Experiment III, both lateral and vertical components of the pelvic trajectory were scaled down from the baseline trajectory. The force field was extended to three dimensions in order to correct the vertical pelvic movement as well. Three subgroups (force feedback alone, visual feedback alone, and both force and visual feedback) were recruited to understand the effects of force feedback and visual feedback alone to distinguish the results from Experiments I and II. The results showthat a trainingmethod that combines visual and force feedback is superior to the training methods with visual or force feedback alone. We believe that the present control strategy holds potential in training and correcting abnormal pelvic movements in different patient populations.

  11. Etalon-induced Baseline Drift And Correction In Atom Flux Sensors Based On Atomic Absorption Spectroscopy

    DOE PAGES

    Du, Yingge; Chambers, Scott A.

    2014-10-20

    Atom flux sensors based on atomic absorption (AA) spectroscopy are of significant interest in thin film growth as they can provide unobtrusive, element specific, real-time flux sensing and control. The ultimate sensitivity and performance of the sensors are strongly affected by the long-term and short term baseline drift. Here we demonstrate that an etalon effect resulting from temperature changes in optical viewport housings is a major source of signal instability which has not been previously considered or corrected by existing methods. We show that small temperature variations in the fused silica viewports can introduce intensity modulations of up to 1.5%,more » which in turn significantly deteriorate AA sensor performance. This undesirable effect can be at least partially eliminated by reducing the size of the beam and tilting the incident light beam off the viewport normal.« less

  12. Comparison of baseline removal methods for laser-induced breakdown spectroscopy of geological samples

    NASA Astrophysics Data System (ADS)

    Dyar, M. Darby; Giguere, Stephen; Carey, CJ; Boucher, Thomas

    2016-12-01

    This project examines the causes, effects, and optimization of continuum removal in laser-induced breakdown spectroscopy (LIBS) to produce the best possible prediction accuracy of elemental composition in geological samples. We compare prediction accuracy resulting from several different techniques for baseline removal, including asymmetric least squares (ALS), adaptive iteratively reweighted penalized least squares (Air-PLS), fully automatic baseline correction (FABC), continuous wavelet transformation, median filtering, polynomial fitting, the iterative thresholding Dietrich method, convex hull/rubber band techniques, and a newly-developed technique for Custom baseline removal (BLR). We assess the predictive performance of these methods using partial least-squares analysis for 13 elements of geological interest, expressed as the weight percentages of SiO2, Al2O3, TiO2, FeO, MgO, CaO, Na2O, K2O, and the parts per million concentrations of Ni, Cr, Zn, Mn, and Co. We find that previously published methods for baseline subtraction generally produce equivalent prediction accuracies for major elements. When those pre-existing methods are used, automated optimization of their adjustable parameters is always necessary to wring the best predictive accuracy out of a data set; ideally, it should be done for each individual variable. The new technique of Custom BLR produces significant improvements in prediction accuracy over existing methods across varying geological data sets, instruments, and varying analytical conditions. These results also demonstrate the dual objectives of the continuum removal problem: removing a smooth underlying signal to fit individual peaks (univariate analysis) versus using feature selection to select only those channels that contribute to best prediction accuracy for multivariate analyses. Overall, the current practice of using generalized, one-method-fits-all-spectra baseline removal results in poorer predictive performance for all methods. The extra steps needed to optimize baseline removal for each predicted variable and empower multivariate techniques with the best possible input data for optimal prediction accuracy are shown to be well worth the slight increase in necessary computations and complexity.

  13. On baseline corrections and uncertainty in response spectrafor baseline variations commonly encountered in digital accelerograph records

    USGS Publications Warehouse

    Akkar, Sinan; Boore, David M.

    2009-01-01

    Most digital accelerograph recordings are plagued by long-period drifts, best seen in the velocity and displacement time series obtained from integration of the acceleration time series. These drifts often result in velocity values that are nonzero near the end of the record. This is clearly unphysical and can lead to inaccurate estimates of peak ground displacement and long-period spectral response. The source of the long-period noise seems to be variations in the acceleration baseline in many cases. These variations could be due to true ground motion (tilting and rotation, as well as local permanent ground deformation), instrumental effects, or analog-to-digital conversion. Very often the trends in velocity are well approximated by a linear trend after the strong shaking subsides. The linearity of the trend in velocity implies that no variations in the baseline could have occurred after the onset of linearity in the velocity time series. This observation, combined with the lack of any trends in the pre-event motion, allows us to compute the time interval in which any baseline variations could occur. We then use several models of the variations in a Monte Carlo procedure to derive a suite of baseline-corrected accelerations for each noise model using records from the 1999 Chi-Chi earthquake and several earthquakes in Turkey. Comparisons of the mean values of the peak ground displacements, spectral displacements, and residual displacements computed from these corrected accelerations for the different noise models can be used as a guide to the accuracy of the baseline corrections. For many of the records considered here the mean values are similar for each noise model, giving confidence in the estimation of the mean values. The dispersion of the ground-motion measures increases with period and is noise-model dependent. The dispersion of inelastic spectra is greater than the elastic spectra at short periods but approaches that of the elastic spectra at longer periods. The elastic spectra from the most basic processing, in which only the pre-event mean is removed from the acceleration time series, do not diverge from the baseline-corrected spectra until periods of 10-20 sec or more for the records studied here, implying that for many engineering purposes elastic spectra can be used from records with no baseline correction or filtering.

  14. HIGH-PRECISION ASTROMETRIC MILLIMETER VERY LONG BASELINE INTERFEROMETRY USING A NEW METHOD FOR ATMOSPHERIC CALIBRATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rioja, M.; Dodson, R., E-mail: maria.rioja@icrar.org

    2011-04-15

    We describe a new method which achieves high-precision very long baseline interferometry (VLBI) astrometry in observations at millimeter (mm) wavelengths. It combines fast frequency-switching observations, to correct for the dominant non-dispersive tropospheric fluctuations, with slow source-switching observations, for the remaining ionospheric dispersive terms. We call this method source-frequency phase referencing. Provided that the switching cycles match the properties of the propagation media, one can recover the source astrometry. We present an analytic description of the two-step calibration strategy, along with an error analysis to characterize its performance. Also, we provide observational demonstrations of a successful application with observations using themore » Very Long Baseline Array at 86 GHz of the pairs of sources 3C274 and 3C273 and 1308+326 and 1308+328 under various conditions. We conclude that this method is widely applicable to mm-VLBI observations of many target sources, and unique in providing bona fide astrometrically registered images and high-precision relative astrometric measurements in mm-VLBI using existing and newly built instruments, including space VLBI.« less

  15. The steroids for corneal ulcers trial: study design and baseline characteristics.

    PubMed

    Srinivasan, Muthiah; Mascarenhas, Jeena; Rajaraman, Revathi; Ravindran, Meenakshi; Lalitha, Prajna; Glidden, David V; Ray, Kathryn J; Hong, Kevin C; Oldenburg, Catherine E; Lee, Salena M; Zegans, Michael E; McLeod, Stephen D; Lietman, Thomas M; Acharya, Nisha R

    2012-02-01

    To provide comprehensive trial methods and baseline data for the Steroids for Corneal Ulcers Trial and to present epidemiological characteristics such as risk factors, causative organisms, and ulcer severity. Baseline data from a 1:1 randomized, placebo-controlled, double-masked clinical trial comparing prednisolone phosphate, 1%, with placebo as adjunctive therapy for the treatment of bacterial corneal ulcers. Eligible patients had a culture-positive bacterial corneal ulcer and had been taking moxifloxacin for 48 hours. The primary outcome for the trial is best spectacle-corrected visual acuity at 3 months from enrollment. This report provides comprehensive baseline data, including best spectacle-corrected visual acuity, infiltrate size, microbiological results, and patient demographics, for patients enrolled in the trial. Of 500 patients enrolled, 97% were in India. Two hundred twenty patients (44%) were agricultural workers. Median baseline visual acuity was 0.84 logMAR (Snellen, 20/125) (interquartile range, 0.36-1.7; Snellen, 20/50 to counting fingers). Baseline visual acuity was not significantly different between the United States and India. Ulcers in India had larger infiltrate/scar sizes (P = .04) and deeper infiltrates (P = .04) and were more likely to be localized centrally (P = .002) than ulcers enrolled in the United States. Gram-positive bacteria were the most common organisms isolated from the ulcers (n = 366, 72%). The Steroids for Corneal Ulcers Trial will compare the use of a topical corticosteroid with placebo as adjunctive therapy for bacterial corneal ulcers. Patients enrolled in this trial had diverse ulcer severity and on average significantly reduced visual acuity at presentation. clinicaltrials.gov Identifier: NCT00324168.

  16. Comparison of Baseline Wander Removal Techniques considering the Preservation of ST Changes in the Ischemic ECG: A Simulation Study

    PubMed Central

    Pilia, Nicolas; Schulze, Walther H. W.; Dössel, Olaf

    2017-01-01

    The most important ECG marker for the diagnosis of ischemia or infarction is a change in the ST segment. Baseline wander is a typical artifact that corrupts the recorded ECG and can hinder the correct diagnosis of such diseases. For the purpose of finding the best suited filter for the removal of baseline wander, the ground truth about the ST change prior to the corrupting artifact and the subsequent filtering process is needed. In order to create the desired reference, we used a large simulation study that allowed us to represent the ischemic heart at a multiscale level from the cardiac myocyte to the surface ECG. We also created a realistic model of baseline wander to evaluate five filtering techniques commonly used in literature. In the simulation study, we included a total of 5.5 million signals coming from 765 electrophysiological setups. We found that the best performing method was the wavelet-based baseline cancellation. However, for medical applications, the Butterworth high-pass filter is the better choice because it is computationally cheap and almost as accurate. Even though all methods modify the ST segment up to some extent, they were all proved to be better than leaving baseline wander unfiltered. PMID:28373893

  17. Improving dementia health literacy using the FLOW mnemonic: pilot findings from the Old SCHOOL hip-hop program.

    PubMed

    Noble, James M; Hedmann, Monique G; Williams, Olajide

    2015-02-01

    Dementia health literacy is low among the public and likely poses a significant barrier to Alzheimer's disease (AD) symptom recognition and treatment, particularly among minority populations already facing higher AD burden. We evaluated the pilot phase of a novel AD health education program, Old SCHOOL (Seniors Can Have Optimal Aging and Ongoing Longevity) Hip-Hop (OSHH), which is designed to enable children to be AD health educational conduits in the home ("child-mediated health communication"). OSHH applied our stroke-validated model of engaging, dynamic, and age- and culturally appropriate curriculum delivered to elementary school-age children (fourth/fifth grades, ages 9-11 years). We assessed AD knowledge among the children at baseline, immediately following the intervention (1-hour program delivered daily over 3 consecutive days), and 3 months later. For key AD symptoms, we developed the FLOW mnemonic (forget, lose, overlook, write/wander); students were additionally taught action plans for recognized symptoms. Seventy-five students completed baseline assessments, and 68 completed posttesting. AD symptoms in FLOW were not well known at baseline (individually ranging from 16% to 71% correct) but were highly learned after 3 days (89% to 98% correct) and retained well after 3 months (80% to 95% correct, p ≤ .01 for all comparisons vs. baseline). AD localization, including its effect on memory and the hippocampus, was also highly learned and retained (p < .001). Eighteen students (24%) reported having a close friend/family member with AD. This study suggests our hip-hop health education model may be an effective method to improve AD health literacy. © 2014 Society for Public Health Education.

  18. The correction of time and temperature effects in MR-based 3D Fricke xylenol orange dosimetry.

    PubMed

    Welch, Mattea L; Jaffray, David A

    2017-04-21

    Previously developed MR-based three-dimensional (3D) Fricke-xylenol orange (FXG) dosimeters can provide end-to-end quality assurance and validation protocols for pre-clinical radiation platforms. FXG dosimeters quantify ionizing irradiation induced oxidation of Fe 2+ ions using pre- and post-irradiation MR imaging methods that detect changes in spin-lattice relaxation rates (R 1   =  [Formula: see text]) caused by irradiation induced oxidation of Fe 2+ . Chemical changes in MR-based FXG dosimeters that occur over time and with changes in temperature can decrease dosimetric accuracy if they are not properly characterized and corrected. This paper describes the characterization, development and utilization of an empirical model-based correction algorithm for time and temperature effects in the context of a pre-clinical irradiator and a 7 T pre-clinical MR imaging system. Time and temperature dependent changes of R 1 values were characterized using variable TR spin-echo imaging. R 1 -time and R 1 -temperature dependencies were fit using non-linear least squares fitting methods. Models were validated using leave-one-out cross-validation and resampling. Subsequently, a correction algorithm was developed that employed the previously fit empirical models to predict and reduce baseline R 1 shifts that occurred in the presence of time and temperature changes. The correction algorithm was tested on R 1 -dose response curves and 3D dose distributions delivered using a small animal irradiator at 225 kVp. The correction algorithm reduced baseline R 1 shifts from  -2.8  ×  10 -2 s -1 to 1.5  ×  10 -3 s -1 . In terms of absolute dosimetric performance as assessed with traceable standards, the correction algorithm reduced dose discrepancies from approximately 3% to approximately 0.5% (2.90  ±  2.08% to 0.20  ±  0.07%, and 2.68  ±  1.84% to 0.46  ±  0.37% for the 10  ×  10 and 8  ×  12 mm 2 fields, respectively). Chemical changes in MR-based FXG dosimeters produce time and temperature dependent R 1 values for the time intervals and temperature changes found in a typical small animal imaging and irradiation laboratory setting. These changes cause baseline R 1 shifts that negatively affect dosimeter accuracy. Characterization, modeling and correction of these effects improved in-field reported dose accuracy to less than 1% when compared to standardized ion chamber measurements.

  19. A variational image-based approach to the correction of susceptibility artifacts in the alignment of diffusion weighted and structural MRI.

    PubMed

    Tao, Ran; Fletcher, P Thomas; Gerber, Samuel; Whitaker, Ross T

    2009-01-01

    This paper presents a method for correcting the geometric and greyscale distortions in diffusion-weighted MRI that result from inhomogeneities in the static magnetic field. These inhomogeneities may due to imperfections in the magnet or to spatial variations in the magnetic susceptibility of the object being imaged--so called susceptibility artifacts. Echo-planar imaging (EPI), used in virtually all diffusion weighted acquisition protocols, assumes a homogeneous static field, which generally does not hold for head MRI. The resulting distortions are significant, sometimes more than ten millimeters. These artifacts impede accurate alignment of diffusion images with structural MRI, and are generally considered an obstacle to the joint analysis of connectivity and structure in head MRI. In principle, susceptibility artifacts can be corrected by acquiring (and applying) a field map. However, as shown in the literature and demonstrated in this paper, field map corrections of susceptibility artifacts are not entirely accurate and reliable, and thus field maps do not produce reliable alignment of EPIs with corresponding structural images. This paper presents a new, image-based method for correcting susceptibility artifacts. The method relies on a variational formulation of the match between an EPI baseline image and a corresponding T2-weighted structural image but also specifically accounts for the physics of susceptibility artifacts. We derive a set of partial differential equations associated with the optimization, describe the numerical methods for solving these equations, and present results that demonstrate the effectiveness of the proposed method compared with field-map correction.

  20. A Hybrid Wavelet-Based Method for the Peak Detection of Photoplethysmography Signals.

    PubMed

    Li, Suyi; Jiang, Shanqing; Jiang, Shan; Wu, Jiang; Xiong, Wenji; Diao, Shu

    2017-01-01

    The noninvasive peripheral oxygen saturation (SpO 2 ) and the pulse rate can be extracted from photoplethysmography (PPG) signals. However, the accuracy of the extraction is directly affected by the quality of the signal obtained and the peak of the signal identified; therefore, a hybrid wavelet-based method is proposed in this study. Firstly, we suppressed the partial motion artifacts and corrected the baseline drift by using a wavelet method based on the principle of wavelet multiresolution. And then, we designed a quadratic spline wavelet modulus maximum algorithm to identify the PPG peaks automatically. To evaluate this hybrid method, a reflective pulse oximeter was used to acquire ten subjects' PPG signals under sitting, raising hand, and gently walking postures, and the peak recognition results on the raw signal and on the corrected signal were compared, respectively. The results showed that the hybrid method not only corrected the morphologies of the signal well but also optimized the peaks identification quality, subsequently elevating the measurement accuracy of SpO 2 and the pulse rate. As a result, our hybrid wavelet-based method profoundly optimized the evaluation of respiratory function and heart rate variability analysis.

  1. A Hybrid Wavelet-Based Method for the Peak Detection of Photoplethysmography Signals

    PubMed Central

    Jiang, Shanqing; Jiang, Shan; Wu, Jiang; Xiong, Wenji

    2017-01-01

    The noninvasive peripheral oxygen saturation (SpO2) and the pulse rate can be extracted from photoplethysmography (PPG) signals. However, the accuracy of the extraction is directly affected by the quality of the signal obtained and the peak of the signal identified; therefore, a hybrid wavelet-based method is proposed in this study. Firstly, we suppressed the partial motion artifacts and corrected the baseline drift by using a wavelet method based on the principle of wavelet multiresolution. And then, we designed a quadratic spline wavelet modulus maximum algorithm to identify the PPG peaks automatically. To evaluate this hybrid method, a reflective pulse oximeter was used to acquire ten subjects' PPG signals under sitting, raising hand, and gently walking postures, and the peak recognition results on the raw signal and on the corrected signal were compared, respectively. The results showed that the hybrid method not only corrected the morphologies of the signal well but also optimized the peaks identification quality, subsequently elevating the measurement accuracy of SpO2 and the pulse rate. As a result, our hybrid wavelet-based method profoundly optimized the evaluation of respiratory function and heart rate variability analysis. PMID:29250135

  2. [PERCUTANEOUS CORRECTION OF FOREFOOT DEFORMITIES IN DIABETIC PATIENTS IN ORDER TO PREVENT PRESSURE SORES - TECHNIQUE AND RESULTS IN 20 CONSECUTIVE PATIENTS].

    PubMed

    Yassin, Mustafa; Garti, Avraham; Heller, Eyal; Weissbrot, Moshe; Robinson, Dror

    2017-04-01

    Diabetes mellitus is a 21st century pandemic. Due to life-span prolongation combined with the increased rate of diabetes, a growing population of patients is afflicted with neuropathic foot deformities. Traditional operative repair of these deformities is associated with a high complication rate and relatively common infection incidence. In recent years, in order to prevent these complications, percutaneous deformity correction methods were developed. Description of experience accumulated in treating 20 consecutive patients with diabetic neuropathic foot deformities treated in a percutaneous fashion. A consecutive series of patients treated at our institute for neuropathic foot deformity was assessed according to a standard protocol using the AOFAS forefoot score and the LUMT score performed at baseline as well as at 6 months and 12 months. Treatment related complications were monitored. All procedures were performed in an ambulatory setting using local anesthesia. A total of 12 patients had soft tissue corrections, and 8 had a combined soft tissue and bone correction. Baseline AOFAS score was 48±7 and improved to 73±9 at six months and 75±7 at one year. LUMT score in 11 patients with a chronic wound decreased from 22±4 to 2±1 at one year post-op. One patient required hospitalization due to post-op bleeding. Percutaneous techniques allow deformity correction of diabetic feet, including those with open wounds in an ambulatory setting with a low complication rate.

  3. Scale Estimation and Correction of the Monocular Simultaneous Localization and Mapping (SLAM) Based on Fusion of 1D Laser Range Finder and Vision Data.

    PubMed

    Zhang, Zhuang; Zhao, Rujin; Liu, Enhai; Yan, Kun; Ma, Yuebo

    2018-06-15

    This article presents a new sensor fusion method for visual simultaneous localization and mapping (SLAM) through integration of a monocular camera and a 1D-laser range finder. Such as a fusion method provides the scale estimation and drift correction and it is not limited by volume, e.g., the stereo camera is constrained by the baseline and overcomes the limited depth range problem associated with SLAM for RGBD cameras. We first present the analytical feasibility for estimating the absolute scale through the fusion of 1D distance information and image information. Next, the analytical derivation of the laser-vision fusion is described in detail based on the local dense reconstruction of the image sequences. We also correct the scale drift of the monocular SLAM using the laser distance information which is independent of the drift error. Finally, application of this approach to both indoor and outdoor scenes is verified by the Technical University of Munich dataset of RGBD and self-collected data. We compare the effects of the scale estimation and drift correction of the proposed method with the SLAM for a monocular camera and a RGBD camera.

  4. EVALUATION OF FULL-FIELD ELECTRORETINOGRAM REDUCTIONS AFTER OCRIPLASMIN TREATMENT

    PubMed Central

    Benz, Matthew S.; Miller, Daniel M.; Antoszyk, Andrew N.; Markoff, Joseph; Kozma, Petra; Meunier, Esmeralda; Sergott, Robert C.

    2018-01-01

    Purpose: To explore a possible association between full-field electroretinograms with vitreomacular adhesion resolution and best-corrected visual acuity as part of the prospective, randomized, double-masked, sham-controlled Ocriplasmin for Treatment for Symptomatic Vitreomacular Adhesion Including Macular Hole (OASIS) trial studying ocriplasmin. Methods: The ERG substudy enrolled 62 of 220 OASIS subjects (randomized 2:1) and analyzed full-field electroretinograms and their association with both vitreomacular adhesion resolution and best-corrected visual acuity from baseline through Month 24. Electroretinogram reductions were defined as acute full-field electroretinogram reductions in amplitude of ≥40% from baseline occurring at postinjection Day 7 or Day 28. Results: In the ocriplasmin group, 16/40 (40%) subjects developed ERG reductions, compared to 1/21 (4.8%) in the sham group; 13/16 (81.3%) and 1/1 (100%) resolved by study end, respectively. A total of 11/16 (68.8%) ocriplasmin-treated subjects with ERG reductions achieved vitreomacular adhesion resolution, compared to those without (9/24, 37.5%). The ocriplasmin-treated subjects with ERG reductions also gained more letters on average (11.3 vs. 9.3 letters) from baseline and had a difference of 6.7 letters in mean best-corrected visual acuity by study end compared to those without ERG reductions. Conclusion: Ocriplasmin-treated subjects with ERG reductions had a higher rate of vitreomacular adhesion resolution and showed better visual improvement than their counterparts without ERG reductions or sham subjects by study end. PMID:28198785

  5. GASS: the Parkes Galactic all-sky survey. II. Stray-radiation correction and second data release

    NASA Astrophysics Data System (ADS)

    Kalberla, P. M. W.; McClure-Griffiths, N. M.; Pisano, D. J.; Calabretta, M. R.; Ford, H. Alyson; Lockman, F. J.; Staveley-Smith, L.; Kerp, J.; Winkel, B.; Murphy, T.; Newton-McGee, K.

    2010-10-01

    Context. The Parkes Galactic all-sky survey (GASS) is a survey of Galactic atomic hydrogen (H i) emission in the southern sky observed with the Parkes 64-m Radio Telescope. The first data release was published by McClure-Griffiths et al. (2009). Aims: We remove instrumental effects that affect the GASS and present the second data release. Methods: We calculate the stray-radiation by convolving the all-sky response of the Parkes antenna with the brightness temperature distribution from the Leiden/Argentine/Bonn (LAB) all sky 21-cm line survey, with major contributions from the 30-m dish of the Instituto Argentino de Radioastronomía (IAR) in the southern sky. Remaining instrumental baselines are corrected using the LAB data for a first guess of emission-free baseline regions. Radio frequency interference is removed by median filtering. Results: After applying these corrections to the GASS we find an excellent agreement with the Leiden/Argentine/Bonn (LAB) survey. The GASS is the highest spatial resolution, most sensitive, and is currently the most accurate H i survey of the Galactic H i emission in the southern sky. We provide a web interface for generation and download of FITS cubes.

  6. Evaluating the functional outcomes of ultrasound-guided botulinum toxin type A injections using the Euro-musculus approach for upper limb spasticity treatment in post-stroke patients; an observational study.

    PubMed

    Buyukavci, Raikan; Akturk, Semra; Ersoy, Yüksel

    2018-02-07

    Ultrasound-guided botulinum toxin type A injection is an effective treatment for spasticity. Euro-musculus spasticity approach is a new method for administering injections to the correct point of the correct muscle. The clinical outcomes of this practical approach is not yet available in the literature. The purpose of this study was to evaluate the effects on spasticity and the functional outcomes of ultrasound guided botulinum toxin type A injections via the Euro-musculus spasticity approach to treat upper limb spasticity in post-stroke patients. An observational study. Inpatient post-stroke patients. Twenty five post-stroke patients with post-stroke upper limb spasticity were recruited. The ultrasound-guided botulinum toxin type A injections were administered into the spastic target muscles using the Euro-musculus spasticity approach, and all of the patients were enrolled in rehabilitation programmes after the injections. This research included the innervation zone and injection site figures and ultrasound images of each muscle in the upper limb. The degree of spasticity was assessed via the Modified Ashworth Scale and the upper limb motor function via the Fugl Meyer Upper Extremity Scale at the baseline and 4 and 12 weeks after the botulinum toxin type A injection. Significant decreases in the Modified Ashworth Scale scores of the upper limb flexor muscle tone measured 4 and 12 weeks after the botulinum toxin type A injection were found when compared to the baseline scores (p<0.025). When compared with the baseline Fugl Meyer Upper Extremity subgroup scores, the sitting position, wrist and total scores at 4 and 12 weeks were significantly improved (p<0.025). However, only the Fugl Meyer Upper Extremity hand scores were significantly improved 12 weeks after the injection (p<0.025). Ultrasound-guided botulinum toxin type A injection via the Euro- musculus spasticity approach is a practical and effective method for administering injections to the correct point of the correct muscle. Ultrasound-guided botulinum toxin type A injections combined with rehabilitation programmes decrease spasticity and improve the upper extremity motor functions in stroke patients. This new approach for ultrasound- guided botulinum toxin type A injection is very practical and effective method for upper extremity spasticity.

  7. Covariate Measurement Error Correction Methods in Mediation Analysis with Failure Time Data

    PubMed Central

    Zhao, Shanshan

    2014-01-01

    Summary Mediation analysis is important for understanding the mechanisms whereby one variable causes changes in another. Measurement error could obscure the ability of the potential mediator to explain such changes. This paper focuses on developing correction methods for measurement error in the mediator with failure time outcomes. We consider a broad definition of measurement error, including technical error and error associated with temporal variation. The underlying model with the ‘true’ mediator is assumed to be of the Cox proportional hazards model form. The induced hazard ratio for the observed mediator no longer has a simple form independent of the baseline hazard function, due to the conditioning event. We propose a mean-variance regression calibration approach and a follow-up time regression calibration approach, to approximate the partial likelihood for the induced hazard function. Both methods demonstrate value in assessing mediation effects in simulation studies. These methods are generalized to multiple biomarkers and to both case-cohort and nested case-control sampling design. We apply these correction methods to the Women's Health Initiative hormone therapy trials to understand the mediation effect of several serum sex hormone measures on the relationship between postmenopausal hormone therapy and breast cancer risk. PMID:25139469

  8. Covariate measurement error correction methods in mediation analysis with failure time data.

    PubMed

    Zhao, Shanshan; Prentice, Ross L

    2014-12-01

    Mediation analysis is important for understanding the mechanisms whereby one variable causes changes in another. Measurement error could obscure the ability of the potential mediator to explain such changes. This article focuses on developing correction methods for measurement error in the mediator with failure time outcomes. We consider a broad definition of measurement error, including technical error, and error associated with temporal variation. The underlying model with the "true" mediator is assumed to be of the Cox proportional hazards model form. The induced hazard ratio for the observed mediator no longer has a simple form independent of the baseline hazard function, due to the conditioning event. We propose a mean-variance regression calibration approach and a follow-up time regression calibration approach, to approximate the partial likelihood for the induced hazard function. Both methods demonstrate value in assessing mediation effects in simulation studies. These methods are generalized to multiple biomarkers and to both case-cohort and nested case-control sampling designs. We apply these correction methods to the Women's Health Initiative hormone therapy trials to understand the mediation effect of several serum sex hormone measures on the relationship between postmenopausal hormone therapy and breast cancer risk. © 2014, The International Biometric Society.

  9. Abnormal myocardial repolarisation in response to hypoxaemia and fenoterol.

    PubMed Central

    Kiely, D. G.; Cargill, R. I.; Grove, A.; Struthers, A. D.; Lipworth, B. J.

    1995-01-01

    BACKGROUND--Prolongation of the QTc interval has been associated with cardiac dysrhythmias and sudden death. QTc dispersion (interlead variability in QTc interval) has recently been proposed as being a more sensitive marker of repolarisation abnormalities and shown to be a more specific index of arrhythmia risk. Although hypoxaemia and fenoterol have previously been shown to prolong the QTc interval, this does not reflect regional myocardial repolarisation abnormalities. METHODS--Electrophysiological effects were measured at baseline and after 30 minutes steady state hypoxaemia at an arterial oxygen saturation (SaO2) of 75-80% (study 1) and at baseline then 30 minutes after inhaled fenoterol 2.4 mg (study 2). From the ECG, lead II corrected QT interval (QTc) and overall corrected QT dispersion were measured using a computer linked digitising tablet according to standard criteria. RESULTS--QTc dispersion was increased during hypoxia compared with baseline values (mean (SE) 69 (6) ms v 50 (5) ms) and after fenoterol compared with baseline (79 (13) v 46 (4) ms), respectively. There was also an increase in QTc interval and heart rate after fenoterol (493 (23) v 420 (6) ms and 98 (3) v 71 (6) bpm, respectively). The heart rate was increased during hypoxaemia compared with baseline (78 (3) v 64 (2) bpm), but no change occurred in the QTc interval. CONCLUSIONS--Both hypoxaemia and fenoterol cause myocardial repolarisation abnormalities in man in terms of increased QTc dispersion, but only fenoterol increased the QTc interval. This may be relevant in the aetiology of arrhythmias in patients with acute severe asthma where beta agonist therapy and hypoxaemia coexist. PMID:7491554

  10. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    PubMed

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P <0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB ( P =0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB ( P <0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  11. Prevalence of Invalid Computerized Baseline Neurocognitive Test Results in High School and Collegiate Athletes

    PubMed Central

    Schatz, Philip; Moser, Rosemarie Scolaro; Solomon, Gary S.; Ott, Summer D.; Karpf, Robin

    2012-01-01

    Context: Limited data are available regarding the prevalence and nature of invalid computerized baseline neurocognitive test data. Objective: To identify the prevalence of invalid baselines on the desktop and online versions of ImPACT and to document the utility of correcting for left-right (L-R) confusion on the desktop version of ImPACT. Design: Cross-sectional study of independent samples of high school (HS) and collegiate athletes who completed the desktop or online versions of ImPACT. Participants or Other Participants: A total of 3769 HS (desktop  =  1617, online  =  2152) and 2130 collegiate (desktop  =  742, online  =  1388) athletes completed preseason baseline assessments. Main Outcome Measure(s): Prevalence of 5 ImPACT validity indicators, with correction for L-R confusion (reversing left and right mouse-click responses) on the desktop version, by test version and group. Chi-square analyses were conducted for sex and attentional or learning disorders. Results: At least 1 invalid indicator was present on 11.9% (desktop) versus 6.3% (online) of the HS baselines and 10.2% (desktop) versus 4.1% (online) of collegiate baselines; correcting for L-R confusion (desktop) decreased this overall prevalence to 8.4% (HS) and 7.5% (collegiate). Online Impulse Control scores alone yielded 0.4% (HS) and 0.9% (collegiate) invalid baselines, compared with 9.0% (HS) and 5.4% (collegiate) on the desktop version; correcting for L-R confusion (desktop) decreased the prevalence of invalid Impulse Control scores to 5.4% (HS) and 2.6% (collegiate). Male athletes and HS athletes with attention deficit or learning disorders who took the online version were more likely to have at least 1 invalid indicator. Utility of additional invalidity indicators is reported. Conclusions: The online ImPACT version appeared to yield fewer invalid baseline results than did the desktop version. Identification of L-R confusion reduces the prevalence of invalid baselines (desktop only) and the potency of Impulse Control as a validity indicator. We advise test administrators to be vigilant in identifying invalid baseline results as part of routine concussion management and prevention programs. PMID:22892410

  12. Effect of baseline corrections on displacements and response spectra for several recordings of the 1999 Chi-Chi, Taiwan, earthquake

    USGS Publications Warehouse

    Boore, D.M.

    2001-01-01

    Displacements derived from many of the accelerogram recordings of the 1999 Chi-Chi, Taiwan, earthquake show drifts when only a simple baseline derived from the pre-event portion of the record is removed from the records. The appearance of the velocity and displacement records suggests that changes in the zero level of the acceleration are responsible for these drifts. The source of the shifts in zero level are unknown, but in at least one case it is almost certainly due to tilting of the ground. This article illustrates the effect on the ground velocity, ground displacement, and response spectra of several schemes for accounting for these baseline shifts. A wide range of final displacements can be obtained for various choices of baseline correction, and comparison with nearby GPS stations (none of which are colocated with the accelerograph stations) do not help in choosing the appropriate baseline correction. The results suggest that final displacements estimated from the records should be used with caution. The most important conclusion for earthquake engineering purposes, however, is that the response spectra for periods less than about 20 sec are usually unaffected by the baseline correction. Although limited to the analysis of only a small number of recordings, the results may have more general significance both for the many other recordings of this earthquake and for data that will be obtained in the future from similar high-quality accelerograph networks now being installed or soon to be installed in many parts of the world.

  13. Patient-specific and global convolutional neural networks for robust automatic liver tumor delineation in follow-up CT studies.

    PubMed

    Vivanti, Refael; Joskowicz, Leo; Lev-Cohain, Naama; Ephrat, Ariel; Sosna, Jacob

    2018-03-10

    Radiological longitudinal follow-up of tumors in CT scans is essential for disease assessment and liver tumor therapy. Currently, most tumor size measurements follow the RECIST guidelines, which can be off by as much as 50%. True volumetric measurements are more accurate but require manual delineation, which is time-consuming and user-dependent. We present a convolutional neural networks (CNN) based method for robust automatic liver tumor delineation in longitudinal CT studies that uses both global and patient specific CNNs trained on a small database of delineated images. The inputs are the baseline scan and the tumor delineation, a follow-up scan, and a liver tumor global CNN voxel classifier built from radiologist-validated liver tumor delineations. The outputs are the tumor delineations in the follow-up CT scan. The baseline scan tumor delineation serves as a high-quality prior for the tumor characterization in the follow-up scans. It is used to evaluate the global CNN performance on the new case and to reliably predict failures of the global CNN on the follow-up scan. High-scoring cases are segmented with a global CNN; low-scoring cases, which are predicted to be failures of the global CNN, are segmented with a patient-specific CNN built from the baseline scan. Our experimental results on 222 tumors from 31 patients yield an average overlap error of 17% (std = 11.2) and surface distance of 2.1 mm (std = 1.8), far better than stand-alone segmentation. Importantly, the robustness of our method improved from 67% for stand-alone global CNN segmentation to 100%. Unlike other medical imaging deep learning approaches, which require large annotated training datasets, our method exploits the follow-up framework to yield accurate tumor tracking and failure detection and correction with a small training dataset. Graphical abstract Flow diagram of the proposed method. In the offline mode (orange), a global CNN is trained as a voxel classifier to segment liver tumor as in [31]. The online mode (blue) is used for each new case. The input is baseline scan with delineation and the follow-up CT scan to be segmented. The main novelty is the ability to predict failures by trying the system on the baseline scan and the ability to correct them using the patient-specific CNN.

  14. Economic evaluation of a mentorship and enhanced supervision program to improve quality of integrated management of childhood illness care in rural Rwanda.

    PubMed

    Manzi, Anatole; Mugunga, Jean Claude; Iyer, Hari S; Magge, Hema; Nkikabahizi, Fulgence; Hirschhorn, Lisa R

    2018-01-01

    Integrated management of childhood illness (IMCI) can reduce under-5 morbidity and mortality in low-income settings. A program to strengthen IMCI practices through Mentorship and Enhanced Supervision at Health centers (MESH) was implemented in two rural districts in eastern Rwanda in 2010. We estimated cost per improvement in quality of care as measured by the difference in correct diagnosis and correct treatment at baseline and 12 months of MESH. Costs of developing and implementing MESH were estimated in 2011 United States Dollars (USD) from the provider perspective using both top-down and bottom-up approaches, from programmatic financial records and site-level data. Improvement in quality of care attributed to MESH was measured through case management observations (n = 292 cases at baseline, 413 cases at 12 months), with outcomes from the intervention already published. Sensitivity analyses were conducted to assess uncertainty under different assumptions of quality of care and patient volume. The total annual cost of MESH was US$ 27,955.74 and the average cost added by MESH per IMCI patient was US$1.06. Salary and benefits accounted for the majority of total annual costs (US$22,400 /year). Improvements in quality of care after 12 months of MESH implementation cost US$2.95 per additional child correctly diagnosed and $5.30 per additional child correctly treated. The incremental costs per additional child correctly diagnosed and child correctly treated suggest that MESH could be an affordable method for improving IMCI quality of care elsewhere in Rwanda and similar settings. Integrating MESH into existing supervision systems would further reduce costs, increasing potential for spread.

  15. Effects of transaldolase exchange on estimates of gluconeogenesis in type 2 diabetes.

    PubMed

    Rajpal, Aman; Dube, Simmi; Carvalho, Filipa; Simoes, Ana Rita; Figueiredo, Angelo; Basu, Ananda; Jones, John; Basu, Rita

    2013-08-15

    Transaldolase (TA) exchange overestimates gluconeogenesis measured with deuterated water (²H₂O). However, it is unknown whether TA differs in people with type 2 diabetes (T2DM). ²H₂O was ingested, and [1-¹³C]acetate and [3-³H]glucose were infused in T2DM (n = 10) and healthy nondiabetic (ND; n = 8) subjects. TA was assessed from the ratio of ¹³C3 to ¹³C4 glucose enrichment (¹³C3/¹³C4) measured by ¹³C NMR. Glucose turnover was measured before (~16-h fast) and during hyperglycemic (~10 mM) moderate-dose insulin (~0.35 mU·kg⁻¹·min⁻¹) clamp. ¹³C3/¹³C4 in T2DM vs. ND was <1.0 and not different at baseline and clamp, indicating equivalent TA. To determine whether incomplete triose phosphate isomerase (TPI) exchange contributed to asymmetric ¹³C3/¹³C4, [U-¹³C]glycerol was infused in lieu of [1-¹³C]acetate during a separate visit in a subset of ND (n = 7) subjects. Ratio of ¹³C3/¹³C4 obtained following either tracer was <1.0 at baseline and during clamp, indicating that TPI exchange was essentially complete and did not contribute to asymmetric glucose enrichment. Uncorrected and corrected rates of gluconeogenesis were no different (P = not significant) in T2DM vs. ND both at baseline and during clamp. TA correction resulted in equivalent estimates of corrected gluconeogenesis in T2DM and ND that were ~25-35% lower than uncorrected gluconeogenesis both at baseline and during the clamp. The asymmetric enrichment of glucose from ¹³C-gluconeogenic tracers is attributable to TA exchange and can be utilized to correct for TA exchange. In conclusion, TA exchange does not differ between T2DM and ND under fasting or hyperglycemic clamp conditions, and the ²H₂O method continues to provide an accurate estimation of gluconeogenesis.

  16. Effects of transaldolase exchange on estimates of gluconeogenesis in type 2 diabetes

    PubMed Central

    Rajpal, Aman; Dube, Simmi; Carvalho, Filipa; Simoes, Ana Rita; Figueiredo, Angelo; Basu, Ananda; Jones, John

    2013-01-01

    Transaldolase (TA) exchange overestimates gluconeogenesis measured with deuterated water (2H2O). However, it is unknown whether TA differs in people with type 2 diabetes (T2DM). 2H2O was ingested, and [1-13C]acetate and [3-3H]glucose were infused in T2DM (n = 10) and healthy nondiabetic (ND; n = 8) subjects. TA was assessed from the ratio of 13C3 to 13C4 glucose enrichment (13C3/13C4) measured by 13C NMR. Glucose turnover was measured before (∼16-h fast) and during hyperglycemic (∼10 mM) moderate-dose insulin (∼0.35 mU·kg−1·min−1) clamp. 13C3/13C4 in T2DM vs. ND was <1.0 and not different at baseline and clamp, indicating equivalent TA. To determine whether incomplete triose phosphate isomerase (TPI) exchange contributed to asymmetric 13C3/13C4, [U-13C]glycerol was infused in lieu of [1-13C]acetate during a separate visit in a subset of ND (n = 7) subjects. Ratio of 13C3/13C4 obtained following either tracer was <1.0 at baseline and during clamp, indicating that TPI exchange was essentially complete and did not contribute to asymmetric glucose enrichment. Uncorrected and corrected rates of gluconeogenesis were no different (P = not significant) in T2DM vs. ND both at baseline and during clamp. TA correction resulted in equivalent estimates of corrected gluconeogenesis in T2DM and ND that were ∼25–35% lower than uncorrected gluconeogenesis both at baseline and during the clamp. The asymmetric enrichment of glucose from 13C-gluconeogenic tracers is attributable to TA exchange and can be utilized to correct for TA exchange. In conclusion, TA exchange does not differ between T2DM and ND under fasting or hyperglycemic clamp conditions, and the 2H2O method continues to provide an accurate estimation of gluconeogenesis. PMID:23736541

  17. Comments on baseline correction of digital strong-motion data: Examples from the 1999 Hector Mine, California, earthquake

    USGS Publications Warehouse

    Boore, D.M.; Stephens, C.D.; Joyner, W.B.

    2002-01-01

    Residual displacements for large earthquakes can sometimes be determined from recordings on modern digital instruments, but baseline offsets of unknown origin make it difficult in many cases to do so. To recover the residual displacement, we suggest tailoring a correction scheme by studying the character of the velocity obtained by integration of zeroth-order-corrected acceleration and then seeing if the residual displacements are stable when the various parameters in the particular correction scheme are varied. For many seismological and engineering purposes, however, the residual displacement are of lesser importance than ground motions at periods less than about 20 sec. These ground motions are often recoverable with simple baseline correction and low-cut filtering. In this largely empirical study, we illustrate the consequences of various correction schemes, drawing primarily from digital recordings of the 1999 Hector Mine, California, earthquake. We show that with simple processing the displacement waveforms for this event are very similar for stations separated by as much as 20 km. We also show that a strong pulse on the transverse component was radiated from the Hector Mine earthquake and propagated with little distortion to distances exceeding 170 km; this pulse leads to large response spectral amplitudes around 10 sec.

  18. Cocaine Dependence Treatment Data: Methods for Measurement Error Problems With Predictors Derived From Stationary Stochastic Processes

    PubMed Central

    Guan, Yongtao; Li, Yehua; Sinha, Rajita

    2011-01-01

    In a cocaine dependence treatment study, we use linear and nonlinear regression models to model posttreatment cocaine craving scores and first cocaine relapse time. A subset of the covariates are summary statistics derived from baseline daily cocaine use trajectories, such as baseline cocaine use frequency and average daily use amount. These summary statistics are subject to estimation error and can therefore cause biased estimators for the regression coefficients. Unlike classical measurement error problems, the error we encounter here is heteroscedastic with an unknown distribution, and there are no replicates for the error-prone variables or instrumental variables. We propose two robust methods to correct for the bias: a computationally efficient method-of-moments-based method for linear regression models and a subsampling extrapolation method that is generally applicable to both linear and nonlinear regression models. Simulations and an application to the cocaine dependence treatment data are used to illustrate the efficacy of the proposed methods. Asymptotic theory and variance estimation for the proposed subsampling extrapolation method and some additional simulation results are described in the online supplementary material. PMID:21984854

  19. Accelerometer-based method for correcting signal baseline changes caused by motion artifacts in medical near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Virtanen, Jaakko; Noponen, Tommi; Kotilahti, Kalle; Virtanen, Juha; Ilmoniemi, Risto J.

    2011-08-01

    In medical near-infrared spectroscopy (NIRS), movements of the subject often cause large step changes in the baselines of the measured light attenuation signals. This prevents comparison of hemoglobin concentration levels before and after movement. We present an accelerometer-based motion artifact removal (ABAMAR) algorithm for correcting such baseline motion artifacts (BMAs). ABAMAR can be easily adapted to various long-term monitoring applications of NIRS. We applied ABAMAR to NIRS data collected in 23 all-night sleep measurements and containing BMAs from involuntary movements during sleep. For reference, three NIRS researchers independently identified BMAs from the data. To determine whether the use of an accelerometer improves BMA detection accuracy, we compared ABAMAR to motion detection based on peaks in the moving standard deviation (SD) of NIRS data. The number of BMAs identified by ABAMAR was similar to the number detected by the humans, and 79% of the artifacts identified by ABAMAR were confirmed by at least two humans. While the moving SD of NIRS data could also be used for motion detection, on average 2 out of the 10 largest SD peaks in NIRS data each night occurred without the presence of movement. Thus, using an accelerometer improves BMA detection accuracy in NIRS.

  20. Are bioequivalence studies of levothyroxine sodium formulations in euthyroid volunteers reliable?

    PubMed

    Blakesley, Vicky; Awni, Walid; Locke, Charles; Ludden, Thomas; Granneman, G Richard; Braverman, Lewis E

    2004-03-01

    Levothyroxine (LT4) has a narrow therapeutic index. Consequently, precise standards for assessing the bioequivalence of different LT4 products are vital. We examined the methodology that the Food and Drug Administration (FDA) recommends for comparing the bioavailability of LT4 products, as well as three modifications to correct for endogenous, thyroxine (T4) levels, to determine if the methodology could distinguish LT4 products that differ by 12.5%, 25%, or 33%. With no baseline correction for the endogenous T4 pool, differences in administered LT4 doses that differed by 25%-33% could not be detected (450 microg and 400 microg doses versus 600 microg dose, respectively). The three mathematical correction methods could distinguish the doses that differed by 25% and 33%. None of the correction methods could distinguish dosage strengths that differed by 12.5% (450 microg versus 400 microg). Dose differences within this range are known to result in clinically relevant differences in safety and effectiveness. Methods of analysis of bioequivalence data that do not consider endogenous T4 concentrations confound accurate quantitation and interpretation of LT4 bioavailability. As a result, products inappropriately deemed bioequivalent may put patients at risk for iatrogenic hyperthyroidism or hypothyroidism. More precise methods for defining bioequivalence are required in order to ensure that LT4 products accepted as bioequivalent will perform equivalently in patients without the need for further monitoring and retitration of their dose.

  1. 49 CFR Appendix C to Part 227 - Audiometric Baseline Revision

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the hearing conservation program. If no appropriate pre-entry audiogram exists, the baseline is the.... Therefore, if the two ears show different hearing trends, the baseline for the left ear may be from one test date, while the baseline for the right ear may be from a different test date. E. Age corrections do not...

  2. Assessment of three dead detector correction methods for cone-beam computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelms, David W.; Shukla, Hemant I.; Nixon, Earl

    Purpose: Dead detectors due to manufacturing defects or radiation damage in the electronic portal imaging devices (EPIDs) used for cone-beam computed tomography (CBCT) can lead to image degradation and ring artifacts. In this work three dead detector correction methods were assessed using megavoltage CBCT (MVCBCT) as a test system, with the goals of assessing the relative effectiveness of the three methods and establishing the conditions for which they fail. Methods: MVCBCT projections acquired with four linacs at 8 and 60 MU (monitor units) were degraded with varying percentages (2%-95%) of randomly distributed dead single detectors (RDSs), randomly distributed dead detectormore » clusters (RDCs) of 2 mm diameter, and nonrandomly distributed dead detector disks (NRDDs) of varying diameter (4-16 mm). Correction algorithms were bidirectional linear interpolation (BLI), quad-directional linear interpolation (QLI), and a Laplacian solution (LS) method. Correction method failure was defined to occur if ring artifacts were present in the reconstructed phantom images from any linac or if the modulation transfer function (MTF) for any linac dropped below baseline with a p value, calculated with the two sample t test, of less than 0.01. Results: All correction methods failed at the same or lower RDC/RDS percentages and NRDD diameters for the 60 MU as for the 8 MU cases. The LS method tended to outperform or match the BLI and QLI methods. If ring artifacts anywhere in the images were considered unacceptable, the LS method failed for 60 MU at >33% RDS, >2% RDC, and >4 mm NRDD. If ring artifacts within 4 mm longitudinally of the phantom section interfaces were considered acceptable, the LS method failed for 60 MU at >90% RDS, >80% RDC, and >4 mm NRDD. LS failed due to MTF drop for 60 MU at >50% RDS, >25% RDC, and >4 mm NRDD. Conclusions: The LS method is superior to the BLI and QLI methods, and correction algorithm effectiveness decreases as imaging dose increases. All correction methods failed first due to ring artifacts and second due to MTF drop. If ring artifacts in axial slices within a 4 mm longitudinal distance from phantom section interfaces are acceptable, statistically significant loss in spatial resolution does not occur until over 25% of the EPID is covered in randomly distributed dead detectors, or NRDDs of 4 mm diameter are present.« less

  3. Improved epileptic seizure detection combining dynamic feature normalization with EEG novelty detection.

    PubMed

    Bogaarts, J G; Hilkman, D M W; Gommer, E D; van Kranen-Mastenbroek, V H J M; Reulen, J P H

    2016-12-01

    Continuous electroencephalographic monitoring of critically ill patients is an established procedure in intensive care units. Seizure detection algorithms, such as support vector machines (SVM), play a prominent role in this procedure. To correct for inter-human differences in EEG characteristics, as well as for intra-human EEG variability over time, dynamic EEG feature normalization is essential. Recently, the median decaying memory (MDM) approach was determined to be the best method of normalization. MDM uses a sliding baseline buffer of EEG epochs to calculate feature normalization constants. However, while this method does include non-seizure EEG epochs, it also includes EEG activity that can have a detrimental effect on the normalization and subsequent seizure detection performance. In this study, EEG data that is to be incorporated into the baseline buffer are automatically selected based on a novelty detection algorithm (Novelty-MDM). Performance of an SVM-based seizure detection framework is evaluated in 17 long-term ICU registrations using the area under the sensitivity-specificity ROC curve. This evaluation compares three different EEG normalization methods, namely a fixed baseline buffer (FB), the median decaying memory (MDM) approach, and our novelty median decaying memory (Novelty-MDM) method. It is demonstrated that MDM did not improve overall performance compared to FB (p < 0.27), partly because seizure like episodes were included in the baseline. More importantly, Novelty-MDM significantly outperforms both FB (p = 0.015) and MDM (p = 0.0065).

  4. Comparative assessment of several post-processing methods for correcting evapotranspiration forecasts derived from TIGGE datasets.

    NASA Astrophysics Data System (ADS)

    Tian, D.; Medina, H.

    2017-12-01

    Post-processing of medium range reference evapotranspiration (ETo) forecasts based on numerical weather prediction (NWP) models has the potential of improving the quality and utility of these forecasts. This work compares the performance of several post-processing methods for correcting ETo forecasts over the continental U.S. generated from The Observing System Research and Predictability Experiment (THORPEX) Interactive Grand Global Ensemble (TIGGE) database using data from Europe (EC), the United Kingdom (MO), and the United States (NCEP). The pondered post-processing techniques are: simple bias correction, the use of multimodels, the Ensemble Model Output Statistics (EMOS, Gneitting et al., 2005) and the Bayesian Model Averaging (BMA, Raftery et al., 2005). ETo estimates based on quality-controlled U.S. Regional Climate Reference Network measurements, and computed with the FAO 56 Penman Monteith equation, are adopted as baseline. EMOS and BMA are generally the most efficient post-processing techniques of the ETo forecasts. Nevertheless, the simple bias correction of the best model is commonly much more rewarding than using multimodel raw forecasts. Our results demonstrate the potential of different forecasting and post-processing frameworks in operational evapotranspiration and irrigation advisory systems at national scale.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sonzogni, A. A.; McCutchan, E. A.; Johnson, T. D.

    Fission yields form an integral part of the prediction of antineutrino spectra generated by nuclear reactors, but little attention has been paid to the quality and reliability of the data used in current calculations. Following a critical review of the thermal and fast ENDF/B-VII.1 235U fission yields, deficiencies are identified and improved yields are obtained, based on corrections of erroneous yields, consistency between decay and fission yield data, and updated isomeric ratios. These corrected yields are used to calculate antineutrino spectra using the summation method. An anomalous value for the thermal fission yield of 86Ge generates an excess of antineutrinosmore » at 5–7 MeV, a feature which is no longer present when the corrected yields are used. Thermal spectra calculated with two distinct fission yield libraries (corrected ENDF/B and JEFF) differ by up to 6% in the 0–7 MeV energy window, allowing for a basic estimate of the uncertainty involved in the fission yield component of summation calculations. Lastly, the fast neutron antineutrino spectrum is calculated, which at the moment can only be obtained with the summation method and may be relevant for short baseline reactor experiments using highly enriched uranium fuel.« less

  6. The effects of partial and full correction of refractive errors on sensorial and motor outcomes in children with refractive accommodative esotropia.

    PubMed

    Sefi-Yurdakul, Nazife; Kaykısız, Hüseyin; Koç, Feray

    2018-03-17

    To investigate the effects of partial and full correction of refractive errors on sensorial and motor outcomes in children with refractive accommodative esotropia (RAE). The records of pediatric cases with full RAE were reviewed; their first and last sensorial and motor findings were evaluated in two groups, classified as partial (Group 1) and full correction (Group 2) of refractive errors. The mean age at first admission was 5.84 ± 3.62 years in Group 1 (n = 35) and 6.35 ± 3.26 years in Group 2 (n = 46) (p = 0.335). Mean change in best corrected visual acuity (BCVA) was 0.24 ± 0.17 logarithm of the minimum angle of resolution (logMAR) in Group 1 and 0.13 ± 0.16 logMAR in Group 2 (p = 0.001). Duration of deviation, baseline refraction and amount of reduced refraction showed significant effects on change in BCVA (p < 0.05). Significant correlation was determined between binocular vision (BOV), duration of deviation and uncorrected baseline amount of deviation (p < 0.05). The baseline BOV rates were significantly high in fully corrected Group 2, and also were found to have increased in Group 1 (p < 0.05). Change in refraction was - 0.09 ± 1.08 and + 0.35 ± 0.76 diopters in Groups 1 and 2, respectively (p = 0.005). Duration of deviation, baseline refraction and the amount of reduced refraction had significant effects on change in refraction (p < 0.05). Change in deviation without refractive correction was - 0.74 ± 7.22 prism diopters in Group 1 and - 3.24 ± 10.41 prism diopters in Group 2 (p = 0.472). Duration of follow-up and uncorrected baseline deviation showed significant effects on change in deviation (p < 0.05). Although the BOV rates and BCVA were initially high in fully corrected patients, they finally improved significantly in both the fully and partially corrected patients. Full hypermetropic correction may also cause an increase in the refractive error with a possible negative effect on emmetropization. The negative effect of the duration of deviation on BOV and BCVA demonstrates the significance of early treatment in RAE cases.

  7. 75 FR 27334 - Acacia Natural Gas Corporation; Notice of Baseline Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-14

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-16-001] Acacia Natural Gas Corporation; Notice of Baseline Filing May 7, 2010. Take notice that on May 5, 2010, Acacia Natural Gas Corporation (Acacia) submitted a correction to its April 27, 2010, baseline filing of its...

  8. Buprenorphine Treatment for Probationers and Parolees

    PubMed Central

    Gordon, Michael S.; Kinlock, Timothy W.; Schwartz, Robert P.; Couvillion, Kathryn A.; Sudec, Laura J.; O’Grady, Kevin E.; Vocci, Frank J.; Shabazz, Hamin

    2014-01-01

    Background Pharmacotherapy studies involving buprenorphine have rarely been conducted with US community corrections populations. This is one of the first reports of buprenorphine treatment outcomes of adult opioid-dependent probationers and parolees. Methods This longitudinal study examined the 3-month treatment outcomes for a sample of probation and parole clients (N=64) who received community-based buprenorphine treatment. Results Approximately two-thirds of the sample (67%) were still in treatment at three months post-baseline. Furthermore, there was a significant decline in the number of self-reported heroin use days and crime days from baseline to three months post-baseline. While there was not a significant reduction in reincarcerations, there was no evidence that they had increased. Conclusions Given that buprenorphine is approved by the FDA as a safe, effective treatment for opioid use disorders, individuals on parole or probation should have the opportunity to benefit from it through community-based programs. PMID:24701967

  9. Similarities in error processing establish a link between saccade prediction at baseline and adaptation performance.

    PubMed

    Wong, Aaron L; Shelhamer, Mark

    2014-05-01

    Adaptive processes are crucial in maintaining the accuracy of body movements and rely on error storage and processing mechanisms. Although classically studied with adaptation paradigms, evidence of these ongoing error-correction mechanisms should also be detectable in other movements. Despite this connection, current adaptation models are challenged when forecasting adaptation ability with measures of baseline behavior. On the other hand, we have previously identified an error-correction process present in a particular form of baseline behavior, the generation of predictive saccades. This process exhibits long-term intertrial correlations that decay gradually (as a power law) and are best characterized with the tools of fractal time series analysis. Since this baseline task and adaptation both involve error storage and processing, we sought to find a link between the intertrial correlations of the error-correction process in predictive saccades and the ability of subjects to alter their saccade amplitudes during an adaptation task. Here we find just such a relationship: the stronger the intertrial correlations during prediction, the more rapid the acquisition of adaptation. This reinforces the links found previously between prediction and adaptation in motor control and suggests that current adaptation models are inadequate to capture the complete dynamics of these error-correction processes. A better understanding of the similarities in error processing between prediction and adaptation might provide the means to forecast adaptation ability with a baseline task. This would have many potential uses in physical therapy and the general design of paradigms of motor adaptation. Copyright © 2014 the American Physiological Society.

  10. Application of ALOS and Envisat Data in Improving Multi-Temporal InSAR Methods for Monitoring Damavand Volcano and Landslide Deformation in the Center of Alborz Mountains, North Iran

    NASA Astrophysics Data System (ADS)

    Vajedian, S.; Motagh, M.; Nilfouroushan, F.

    2013-09-01

    InSAR capacity to detect slow deformation over terrain areas is limited by temporal and geometric decorrelations. Multitemporal InSAR techniques involving Persistent Scatterer (Ps-InSAR) and Small Baseline (SBAS) are recently developed to compensate the decorrelation problems. Geometric decorrelation in mountainous areas especially for Envisat images makes phase unwrapping process difficult. To improve this unwrapping problem, we first modified phase filtering to make the wrapped phase image as smooth as possible. In addition, in order to improve unwrapping results, a modified unwrapping method has been developed. This method includes removing possible orbital and tropospheric effects. Topographic correction is done within three-dimensional unwrapping, Orbital and tropospheric corrections are done after unwrapping process. To evaluate the effectiveness of our improved method we tested the proposed algorithm by Envisat and ALOS dataset and compared our results with recently developed PS software (StaMAPS). In addition we used GPS observations for evaluating the modified method. The results indicate that our method improves the estimated deformation significantly.

  11. Uniformly Processed Strong Motion Database for Himalaya and Northeast Region of India

    NASA Astrophysics Data System (ADS)

    Gupta, I. D.

    2018-03-01

    This paper presents the first uniformly processed comprehensive database on strong motion acceleration records for the extensive regions of western Himalaya, northeast India, and the alluvial plains juxtaposing the Himalaya. This includes 146 three components of old analog records corrected for the instrument response and baseline distortions and 471 three components of recent digital records corrected for baseline errors. The paper first provides a background of the evolution of strong motion data in India and the seismotectonics of the areas of recording, then describes the details of the recording stations and the contributing earthquakes, which is finally followed by the methodology used to obtain baseline corrected data in a uniform and consistent manner. Two different schemes in common use for baseline correction are based on the application of the Ormsby filter without zero pads (Trifunac 1971) and that on the Butterworth filter with zero pads at the start as well as at the end (Converse and Brady 1992). To integrate the advantages of both the schemes, Ormsby filter with zero pads at the start only is used in the present study. A large number of typical example results are presented to illustrate that the methodology adopted is able to provide realistic velocity and displacement records with much smaller number of zero pads. The present strong motion database of corrected acceleration records will be useful for analyzing the ground motion characteristics of engineering importance, developing prediction equations for various strong motion parameters, and calibrating the seismological source model approach for ground motion simulation for seismically active and risk prone areas of India.

  12. Age-related prevalence and met need for correctable and uncorrectable near vision impairment in a multi-country study.

    PubMed

    He, Mingguang; Abdou, Amza; Ellwein, Leon B; Naidoo, Kovin S; Sapkota, Yuddha D; Thulasiraj, R D; Varma, Rohit; Zhao, Jialiang; Kocur, Ivo; Congdon, Nathan G

    2014-01-01

    To estimate the prevalence, potential determinants, and proportion of met need for near vision impairment (NVI) correctable with refraction approximately 2 years after initial examination of a multi-country cohort. Population-based, prospective cohort study. People aged ≥35 years examined at baseline in semi-rural (Shunyi) and urban (Guangzhou) sites in China; rural sites in Nepal (Kaski), India (Madurai), and Niger (Dosso); a semi-urban site (Durban) in South Africa; and an urban site (Los Angeles) in the United States. Near visual acuity (NVA) with and without current near correction was measured at 40 cm using a logarithm of the minimum angle of resolution near vision tumbling E chart. Participants with uncorrected binocular NVA ≤20/40 were tested with plus sphere lenses to obtain best-corrected binocular NVA. Prevalence of total NVI (defined as uncorrected NVA ≤20/40) and NVI correctable and uncorrectable to >20/40, and current spectacle wearing among those with bilateral NVA ≤20/63 improving to >20/40 with near correction (met need). Among 13 671 baseline participants, 10 533 (77.2%) attended the follow-up examination. The prevalence of correctable NVI increased with age from 35 to 50-60 years and then decreased at all sites. Multiple logistic regression modeling suggested that correctable NVI was not associated with gender at any site, whereas more educated persons aged >54 years were associated with a higher prevalence of correctable NVI in Nepal and India. Although near vision spectacles were provided free at baseline, wear among those who could benefit was <40% at all but 2 centers (Guangzhou and Los Angeles). Prevalence of correctable NVI is greatest among persons of working age, and rates of correction are low in many settings, suggesting that strategies targeting the workplace may be needed. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  13. Solving matrix-effects exploiting the second order advantage in the resolution and determination of eight tetracycline antibiotics in effluent wastewater by modelling liquid chromatography data with multivariate curve resolution-alternating least squares and unfolded-partial least squares followed by residual bilinearization algorithms I. Effect of signal pre-treatment.

    PubMed

    De Zan, M M; Gil García, M D; Culzoni, M J; Siano, R G; Goicoechea, H C; Martínez Galera, M

    2008-02-01

    The effect of piecewise direct standardization (PDS) and baseline correction approaches was evaluated in the performance of multivariate curve resolution (MCR-ALS) algorithm for the resolution of three-way data sets from liquid chromatography with diode-array detection (LC-DAD). First, eight tetracyclines (tetracycline, oxytetracycline, chlorotetracycline, demeclocycline, methacycline, doxycycline, meclocycline and minocycline) were isolated from 250 mL effluent wastewater samples by solid-phase extraction (SPE) with Oasis MAX 500 mg/6 mL cartridges and then separated on an Aquasil C18 150 mm x 4.6mm (5 microm particle size) column by LC and detected by DAD. Previous experiments, carried out with Milli-Q water samples, showed a considerable loss of the most polar analytes (minocycline, oxitetracycline and tetracycline) due to breakthrough. PDS was applied to overcome this important drawback. Conversion of chromatograms obtained from standards prepared in solvent was performed obtaining a high correlation with those corresponding to the real situation (r2 = 0.98). Although the enrichment and clean-up steps were carefully optimized, the sample matrix caused a large baseline drift, and also additive interferences were present at the retention times of the analytes. These problems were solved with the baseline correction method proposed by Eilers. MCR-ALS was applied to the corrected and uncorrected three-way data sets to obtain spectral and chromatographic profiles of each tetracycline, as well as those corresponding to the co-eluting interferences. The complexity of the calibration model built from uncorrected data sets was higher, as expected, and the quality of the spectral and chromatographic profiles was worse.

  14. Direct determination of sorbitol and sodium glutamate by attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) in the thermostabilizer employed in the production of yellow-fever vaccine.

    PubMed

    de Castro, Eduardo da S G; Cassella, Ricardo J

    2016-05-15

    Reference methods for quality control of vaccines usually require treatment of the samples before analysis. These procedures are expensive, time-consuming, unhealthy and require careful manipulation of the sample, making them a potential source of analytical errors. This work proposes a novel method for the quality control of thermostabilizer samples of the yellow fever vaccine employing attenuated total reflectance Fourier transform infrared spectrometry (ATR-FTIR). The main advantage of the proposed method is the possibility of direct determination of the analytes (sodium glutamate and sorbitol) without any pretreatment of the samples. Operational parameters of the FTIR technique, such as the number of accumulated scans and nominal resolution, were evaluated. The best conditions for sodium glutamate were achieved when 64 scans were accumulated using a nominal resolution of 4 cm(-1). The measurements for sodium glutamate were performed at 1347 cm(-1) (baseline correction between 1322 and 1369 cm(-1)). In the case of sorbitol, the measurements were done at 890cm(-1) (baseline correction between 825 and 910 cm(-1)) using a nominal resolution of 2 cm(-1) with 32 accumulated scans. In both cases, the quantitative variable was the band height. Recovery tests were performed in order to evaluate the accuracy of the method and recovery percentages in the range 93-106% were obtained. Also, the methods were compared with reference methods and no statistical differences were observed. The limits of detection and quantification for sodium glutamate were 0.20 and 0.62% (m/v), respectively, whereas for sorbitol they were 1 and 3.3% (m/v), respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Quantitative Evaluation of Electrodes for External Urethral Sphincter Electromyography during Bladder-to-Urethral Guarding Reflex

    PubMed Central

    Steward, James E.; Clemons, Jessica D.; Zaszczurynski, Paul J.; Butler, Robert S.; Damaser, Margot S.; Jiang, Hai-Hong

    2009-01-01

    Purpose Accuracy in the recording of external urethral sphincter (EUS) electromyography (EMG) is an important goal in the quantitative evaluation of urethral function. This study aim was to quantitatively compare electrode recordings taken during tonic activity and leak point pressure (LPP) testing. Methods Several electrodes, including the surface electrode (SE), concentric electrode (CE), and wire electrode (WE), were placed on the EUS singly and simultaneously in six female Sprague-Dawley rats under urethane anesthesia. The bladder was filled via a retropubic catheter while LPP testing and EUS EMG recording were done. Quantitative baseline correction of the EUS EMG signal was performed to reduce baseline variation. Amplitude and frequency of one-second samples of the EUS EMG signal were measured before LPP (tonic activity) and during peak LPP activity. Results The SE, CE, and WE signals demonstrated tonic activity before LPP and an increase in activity during LPP, suggesting that the electrodes accurately recorded EUS activity during tonic activity and during the bladder-to-EUS guarding reflex, regardless of the size or location of detection areas. SE recordings required significantly less baseline correction than both CE and WE recordings. The activity in CE-recorded EMG was significantly higher than that of the SE and WE both in single and simultaneous recordings. Conclusions These electrodes may be suitable for testing EUS EMG activity. The SE signal had significantly less baseline variation and the CE detected local activity more sensitively than the other electrodes, which may provide insight into choosing an appropriate electrode for EUS EMG recording. PMID:19680661

  16. Improved Modeling of Finite-Rate Turbulent Combustion Processes in Research Combustors

    NASA Technical Reports Server (NTRS)

    VanOverbeke, Thomas J.

    1998-01-01

    The objective of this thesis is to further develop and test a stochastic model of turbulent combustion in recirculating flows. There is a requirement to increase the accuracy of multi-dimensional combustion predictions. As turbulence affects reaction rates, this interaction must be more accurately evaluated. In this work a more physically correct way of handling the interaction of turbulence on combustion is further developed and tested. As turbulence involves randomness, stochastic modeling is used. Averaged values such as temperature and species concentration are found by integrating the probability density function (pdf) over the range of the scalar. The model in this work does not assume the pdf type, but solves for the evolution of the pdf using the Monte Carlo solution technique. The model is further developed by including a more robust reaction solver, by using accurate thermodynamics and by more accurate transport elements. The stochastic method is used with Semi-Implicit Method for Pressure-Linked Equations. The SIMPLE method is used to solve for velocity, pressure, turbulent kinetic energy and dissipation. The pdf solver solves for temperature and species concentration. Thus, the method is partially familiar to combustor engineers. The method is compared to benchmark experimental data and baseline calculations. The baseline method was tested on isothermal flows, evaporating sprays and combusting sprays. Pdf and baseline predictions were performed for three diffusion flames and one premixed flame. The pdf method predicted lower combustion rates than the baseline method in agreement with the data, except for the premixed flame. The baseline and stochastic predictions bounded the experimental data for the premixed flame. The use of a continuous mixing model or relax to mean mixing model had little effect on the prediction of average temperature. Two grids were used in a hydrogen diffusion flame simulation. Grid density did not effect the predictions except for peak temperature and tangential velocity. The hybrid pdf method did take longer and required more memory, but has a theoretical basis to extend to many reaction steps which cannot be said of current turbulent combustion models.

  17. Deformation Monitoring of the Submillimetric UPV Calibration Baseline

    NASA Astrophysics Data System (ADS)

    García-Asenjo, Luis; Baselga, Sergio; Garrigues, Pascual

    2017-06-01

    A 330 m calibration baseline was established at the Universitat Politècnica de València (UPV) in 2007. Absolute scale was subsequently transferred in 2012 from the Nummela Standard Baseline in Finland and distances between pillars were determined with uncertainties ranging from 0.1 mm to 0.3 mm. In order to assess the long-term stability of the baseline three field campaigns were carried out from 2013 to 2015 in a co-operative effort with the Universidad Complutense de Madrid (UCM), which provided the only Mekometer ME5000 distance meter available in Spain. Since the application of the ISO17123-4 full procedure did not suffice to come to a definite conclusion about possible displacements of the pillars, we opted for the traditional geodetic network approach. This approach had to be adapted to the case at hand in order to deal with problems such as the geometric weakness inherent to calibration baselines and scale uncertainty derived from both the use of different instruments and the high correlation between the meteorological correction and scale determination. Additionally, the so-called the maximum number of stable points method was also tested. In this contribution it is described the process followed to assess the stability of the UPV submillimetric calibration baseline during the period of time from 2012 to 2015.

  18. Accuracy of contrast-enhanced ultrasound in the detection of bladder cancer

    PubMed Central

    Nicolau, C; Bunesch, L; Peri, L; Salvador, R; Corral, J M; Mallofre, C; Sebastia, C

    2011-01-01

    Objective To assess the accuracy contrast-enhanced ultrasound (CEUS) in bladder cancer detection using transurethral biopsy in conventional cystoscopy as the reference standard and to determine whether CEUS improves the bladder cancer detection rate of baseline ultrasound. Methods 43 patients with suspected bladder cancer underwent conventional cystoscopy with transurethral biopsy of the suspicious lesions. 64 bladder cancers were confirmed in 33 out of 43 patients. Baseline ultrasound and CEUS were performed the day before surgery and the accuracy of both techniques for bladder cancer detection and number of detected tumours were analysed and compared with the final diagnosis. Results CEUS was significantly more accurate than ultrasound in determining presence or absence of bladder cancer: 88.37% vs 72.09%. Seven of eight uncertain baseline ultrasound results were correctly diagnosed using CEUS. CEUS sensitivity was also better than that of baseline ultrasound per number of tumours: 65.62% vs 60.93%. CEUS sensitivity for bladder cancer detection was very high for tumours larger than 5 mm (94.7%) but very low for tumours <5 mm (20%) and also had a very low negative predictive value (28.57%) in tumours <5 mm. Conclusion CEUS provided higher accuracy than baseline ultrasound for bladder cancer detection, being especially useful in non-conclusive baseline ultrasound studies. PMID:21123306

  19. Assessment of a quality improvement intervention to strengthen pharmaceutical human resources and improve availability and use of HIV medicines in Uganda.

    PubMed

    Byabagambi, John B; Broughton, Edward; Heltebeitel, Simon; Wuliji, Tana; Karamagi, Esther

    2017-01-01

    Inadequate medication dispensing and management by healthcare providers can contribute to poor outcomes among HIV-positive patients. Gaps in medication availability, often associated with pharmacy workforce shortages, are an important barrier to retention in HIV care in Uganda. An intervention to address pharmacy staffing constraints through strengthening pharmaceutical management, dispensing practices, and general competencies of facility clinical and pharmacy staff was implemented in 14 facilities in three districts in eastern Uganda. Teams of staff were organised in each facility and supported to apply quality improvement (QI) methods to address deficits in availability and rational use of HIV drugs. To evaluate the intervention, baseline and end line data were collected 24 months apart. Dispensing practices, clinical wellness and adherence to antiretrovirals improved by 45%, 28% and 20% from baseline to end line, respectively. All clients at end line received the medications prescribed, and medications were correctly, completely and legibly labelled more often. Clients better understood when, how much and for how long they were supposed to take their prescribed medicines at end line. Pharmaceutical management practices also improved from baseline in most categories by statistically significant margins. Facilities significantly improved on correctly recording stock information about antiretroviral drugs (53%vs100%, P<0.0001). Coinciding with existing staff taking on pharmaceutical roles, facilities improved management of unwanted and expired drugs, notably by optimising use of existing health workers and making pharmaceutical management processes more efficient. Implementation of this improvement intervention in the 14 facilities appeared to have a positive impact on client outcomes, pharmacy department management and providers' self-reported knowledge of QI methods. These results were achieved at a cost of about US$5.50 per client receiving HIV services at participating facilities.

  20. Network Adjustment of Orbit Errors in SAR Interferometry

    NASA Astrophysics Data System (ADS)

    Bahr, Hermann; Hanssen, Ramon

    2010-03-01

    Orbit errors can induce significant long wavelength error signals in synthetic aperture radar (SAR) interferograms and thus bias estimates of wide-scale deformation phenomena. The presented approach aims for correcting orbit errors in a preprocessing step to deformation analysis by modifying state vectors. Whereas absolute errors in the orbital trajectory are negligible, the influence of relative errors (baseline errors) is parametrised by their parallel and perpendicular component as a linear function of time. As the sensitivity of the interferometric phase is only significant with respect to the perpendicular base-line and the rate of change of the parallel baseline, the algorithm focuses on estimating updates to these two parameters. This is achieved by a least squares approach, where the unwrapped residual interferometric phase is observed and atmospheric contributions are considered to be stochastic with constant mean. To enhance reliability, baseline errors are adjusted in an overdetermined network of interferograms, yielding individual orbit corrections per acquisition.

  1. Improved peak detection in mass spectrum by incorporating continuous wavelet transform-based pattern matching.

    PubMed

    Du, Pan; Kibbe, Warren A; Lin, Simon M

    2006-09-01

    A major problem for current peak detection algorithms is that noise in mass spectrometry (MS) spectra gives rise to a high rate of false positives. The false positive rate is especially problematic in detecting peaks with low amplitudes. Usually, various baseline correction algorithms and smoothing methods are applied before attempting peak detection. This approach is very sensitive to the amount of smoothing and aggressiveness of the baseline correction, which contribute to making peak detection results inconsistent between runs, instrumentation and analysis methods. Most peak detection algorithms simply identify peaks based on amplitude, ignoring the additional information present in the shape of the peaks in a spectrum. In our experience, 'true' peaks have characteristic shapes, and providing a shape-matching function that provides a 'goodness of fit' coefficient should provide a more robust peak identification method. Based on these observations, a continuous wavelet transform (CWT)-based peak detection algorithm has been devised that identifies peaks with different scales and amplitudes. By transforming the spectrum into wavelet space, the pattern-matching problem is simplified and in addition provides a powerful technique for identifying and separating the signal from the spike noise and colored noise. This transformation, with the additional information provided by the 2D CWT coefficients can greatly enhance the effective signal-to-noise ratio. Furthermore, with this technique no baseline removal or peak smoothing preprocessing steps are required before peak detection, and this improves the robustness of peak detection under a variety of conditions. The algorithm was evaluated with SELDI-TOF spectra with known polypeptide positions. Comparisons with two other popular algorithms were performed. The results show the CWT-based algorithm can identify both strong and weak peaks while keeping false positive rate low. The algorithm is implemented in R and will be included as an open source module in the Bioconductor project.

  2. Effects of fission yield data in the calculation of antineutrino spectra for U 235 ( n , fission ) at thermal and fast neutron energies

    DOE PAGES

    Sonzogni, A. A.; McCutchan, E. A.; Johnson, T. D.; ...

    2016-04-01

    Fission yields form an integral part of the prediction of antineutrino spectra generated by nuclear reactors, but little attention has been paid to the quality and reliability of the data used in current calculations. Following a critical review of the thermal and fast ENDF/B-VII.1 235U fission yields, deficiencies are identified and improved yields are obtained, based on corrections of erroneous yields, consistency between decay and fission yield data, and updated isomeric ratios. These corrected yields are used to calculate antineutrino spectra using the summation method. An anomalous value for the thermal fission yield of 86Ge generates an excess of antineutrinosmore » at 5–7 MeV, a feature which is no longer present when the corrected yields are used. Thermal spectra calculated with two distinct fission yield libraries (corrected ENDF/B and JEFF) differ by up to 6% in the 0–7 MeV energy window, allowing for a basic estimate of the uncertainty involved in the fission yield component of summation calculations. Lastly, the fast neutron antineutrino spectrum is calculated, which at the moment can only be obtained with the summation method and may be relevant for short baseline reactor experiments using highly enriched uranium fuel.« less

  3. Multiple Acquisition InSAR Analysis: Persistent Scatterer and Small Baseline Approaches

    NASA Astrophysics Data System (ADS)

    Hooper, A.

    2006-12-01

    InSAR techniques that process data from multiple acquisitions enable us to form time series of deformation and also allow us to reduce error terms present in single interferograms. There are currently two broad categories of methods that deal with multiple images: persistent scatterer methods and small baseline methods. The persistent scatterer approach relies on identifying pixels whose scattering properties vary little with time and look angle. Pixels that are dominated by a singular scatterer best meet these criteria; therefore, images are processed at full resolution to both increase the chance of there being only one dominant scatterer present, and to reduce the contribution from other scatterers within each pixel. In images where most pixels contain multiple scatterers of similar strength, even at the highest possible resolution, the persistent scatterer approach is less optimal, as the scattering characteristics of these pixels vary substantially with look angle. In this case, an approach that interferes only pairs of images for which the difference in look angle is small makes better sense, and resolution can be sacrificed to reduce the effects of the look angle difference by band-pass filtering. This is the small baseline approach. Existing small baseline methods depend on forming a series of multilooked interferograms and unwrapping each one individually. This approach fails to take advantage of two of the benefits of processing multiple acquisitions, however, which are usually embodied in persistent scatterer methods: the ability to find and extract the phase for single-look pixels with good signal-to-noise ratio that are surrounded by noisy pixels, and the ability to unwrap more robustly in three dimensions, the third dimension being that of time. We have developed, therefore, a new small baseline method to select individual single-look pixels that behave coherently in time, so that isolated stable pixels may be found. After correction for various error terms, the phase values of the selected pixels are unwrapped using a new three-dimensional algorithm. We apply our small baseline method to an area in southern Iceland that includes Katla and Eyjafjallajökull volcanoes, and retrieve a time series of deformation that shows transient deformation due to intrusion of magma beneath Eyjafjallajökull. We also process the data using the Stanford method for persistent scatterers (StaMPS) for comparison.

  4. Progression of Near Vision Loss and Incidence of Near Vision Impairment in an Adult Chinese Population.

    PubMed

    Han, Xiaotong; Ellwein, Leon B; Guo, Xinxing; Hu, Yin; Yan, William; He, Mingguang

    2017-05-01

    To investigate the progression of near vision loss and the cumulative incidence of near vision impairment (NVI) 6 years after initial examination of an urban Chinese cohort. Population-based, prospective cohort study. People aged ≥35 years examined at baseline in the Yuexiu District of Guangzhou, China. Participants examined at baseline were invited for 2-year and 6-year follow-up examinations in 2010 and 2014, respectively. Examinations included noncycloplegic autorefraction and binocular near visual acuity (NVA) with and without current near correction measured at 40 cm using a LogMAR ETDRS near vision tumbling E chart. Those with uncorrected binocular NVA (UCNVA) ≤20/40 underwent subjective refraction to obtain best-corrected binocular NVA (BCNVA). Change in UCNVA between baseline and 2014 follow-up examinations and the 6-year cumulative incidence of vision impairment based on 3 definitions: NVA ≤20/40, ≤20/50, and ≤20/63. Among the 1817 baseline participants, 1595 (87.8%) were reexamined in 2010 and 1427 (78.5%) in 2014. Mean vision loss between baseline and the 2014 follow-up was 1.54 (±1.74) lines of UCNVA. Vision loss was associated with age 80 years or older, less education, and better baseline UCNVA. The 6-year cumulative incidence of uncorrected binocular NVI (UCNVI) across the 3 vision impairment definitions was 55.2% (95% confidence interval [CI], 46.1%-64.3%), 51.3% (95% CI, 44.0%-58.7%), and 42.4% (95% CI, 35.5%-49.3%), respectively. With best-corrected binocular NVI (BCNVI), incidence was 6.89% (95% CI, 4.28%-9.50%), 5.17% (95% CI, 2.89%-7.44%), and 2.62% (95% CI, 1.11%-4.12%), respectively. A higher incidence of UCNVI was associated with worse baseline UCNVA for all 3 impairment definitions. Similarly, incidence of BCNVI was associated with worse baseline BCNVA, but also with older age and education at the primary level or less. Gender was not significant for either UCNVI or BCNVI. Approximately half of those aged 35 years or older develop UCNVI in 6 years, the overwhelming majority of whom can be corrected with spectacles. Cost-effective strategies to provide spectacles to this at-risk population remains an issue requiring further study. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  5. The effect of bifocal add on accommodative lag in myopic children with high accommodative lag.

    PubMed

    Berntsen, David A; Mutti, Donald O; Zadnik, Karla

    2010-12-01

    To determine the effect of a bifocal add and manifest correction on accommodative lag in myopic children with high accommodative lag, who have been reported to have the greatest reduction in myopia progression with progressive addition lenses (PALs). Monocular accommodative lag to a 4-D Badal stimulus was measured on two occasions 6 months apart in 83 children (mean ± SD age, 9.9 ± 1.3 years) with high lag randomized to wearing single-vision lenses (SVLs) or PALs. Accommodative lag was measured with the following corrections: habitual, manifest, manifest with +2.00-D add, and habitual with +2.00-D add (6-month visit only). At baseline, accommodative lag was higher (1.72 ± 0.37 D; mean ± SD) when measured with manifest correction than with habitual correction (1.51 ± 0.50; P < 0.05). This higher lag with manifest correction correlated with a larger amount of habitual undercorrection at baseline (r = -0.29, P = 0.009). A +2.00-D add over the manifest correction reduced lag by 0.45 ± 0.34 D at baseline and 0.33 ± 0.38 D at the 6-month visit. Lag results at 6 months were not different between PAL and SVL wearers (P = 0.92). A +2.00-D bifocal add did not eliminate accommodative lag and reduced lag by less than 25% of the bifocal power, indicating that children mainly responded to a bifocal by decreasing accommodation. If myopic progression is substantial, measuring lag with full correction can overestimate the hyperopic retinal blur that a child most recently experienced. (ClinicalTrials.gov number, NCT00335049.).

  6. Normal peer models and autistic children's learning.

    PubMed Central

    Egel, A L; Richman, G S; Koegel, R L

    1981-01-01

    Present research and legislation regarding mainstreaming autistic children into normal classrooms have raised the importance of studying whether autistic children can benefit from observing normal peer models. The present investigation systematically assessed whether autistic children's learning of discrimination tasks could be improved if they observed normal children perform the tasks correctly. In the context of a multiple baseline design, four autistic children worked on five discrimination tasks that their teachers reported were posing difficulty. Throughout the baseline condition the children evidenced very low levels of correct responding on all five tasks. In the subsequent treatment condition, when normal peers modeled correct responses, the autistic children's correct responding increased dramatically. In each case, the peer modeling procedure produced rapid achievement of the acquisition which was maintained after the peer models were removed. These results are discussed in relation to issues concerning observational learning and in relation to the implications for mainstreaming autistic children into normal classrooms. PMID:7216930

  7. An online spaced-education game for global continuing medical education: a randomized trial.

    PubMed

    Kerfoot, B Price; Baker, Harley

    2012-07-01

    To assess the efficacy of a "spaced-education" game as a method of continuing medical education (CME) among physicians across the globe. The efficacy of educational games for the CME has yet to be established. We created a novel online educational game by incorporating game mechanics into "spaced education" (SE), an evidence-based method of online CME. This 34-week randomized trial enrolled practicing urologists across the globe. The SE game consisted of 40 validated multiple-choice questions and explanations on urology clinical guidelines. Enrollees were randomized to 2 cohorts: cohort A physicians were sent 2 questions via an automated e-mail system every 2 days, and cohort B physicians were sent 4 questions every 4 days. Adaptive game mechanics re-sent the questions in 12 or 24 days if answered incorrectly and correctly, respectively. Questions expired if not answered on time (appointment dynamic). Physicians retired questions by answering each correctly twice-in-a-row (progression dynamic). Competition was fostered by posting relative performance among physicians. Main outcome measures were baseline scores (percentage of questions answered correctly upon initial presentation) and completion scores (percentage of questions retired). A total of 1470 physicians from 63 countries enrolled. Median baseline score was 48% (interquartile range [IQR] 17) and, in multivariate analyses, was found to vary significantly by region (Cohen dmax = 0.31, P = 0.001) and age (dmax = 0.41, P < 0.001). Median completion score was 98% (IQR 25) and varied significantly by age (dmax = 0.21, P < 0.001) and American Board of Urology certification (d = 0.10, P = 0.033) but not by region (multivariate analyses). Question clustering reduced physicians' performance (d = 0.43, P < 0.001). Seventy-six percent of enrollees (1111/1470) requested to participate in future SE games. An online SE game can substantially improve guidelines knowledge and is a well-accepted method of global CME delivery.

  8. Research in geodesy and geophysics based upon radio-interferometric observations of extragalactic radio sources. Final report, December 1984-December 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, T.A.; Davis, J.L.; Gwinn, C.R.

    1986-10-01

    This report consists of a collection of reprints and preprints. Subjects included: description of Mk-III system for very-long-baseline interferometry (VLBI); geodetic results from the Mk-I and Mk-III systems for VLBI; effects of modeling atmospheric propagation on estimates of baseline length and station height; an improved model for the dry propagation delay; corrections to IAU 1980 nutation series based on VLBI data and geophysical interpretation of those corrections; and a review of the contributions of VLBI to geodynamic studies.

  9. Changes in Liver Volume in Patients with Chronic Hepatitis C Undergoing Antiviral Therapy

    PubMed Central

    Fitzpatrick, Julie A.; Kim, Jin Un; Cobbold, Jeremy F.L.; McPhail, Mark J.W.; Crossey, Mary M.E.; Bak-Bol, Aluel A.; Zaky, Ashraf; Taylor-Robinson, Simon D.

    2016-01-01

    Aim Liver volumetric analysis has not been used to detect hepatic remodelling during antiviral therapy before. We measured liver volume (LV) changes on volumetric magnetic resonance imaging during hepatitis C antiviral therapy. Methods 22 biopsy-staged patients (median [range] age 4519–65 years; 9F, 13M) with chronic hepatitis C virus infection were studied. LV was measured at the beginning, end of treatment and 6 months post-treatment using 3D T1-weighted acquisition, normalised to patient weight. Liver outlines were drawn manually on 4 mm thick image slices and LV calculated. Inter-observer agreement was analysed. Patients were also assessed longitudinally using biochemical parameters and liver stiffness using Fibroscan™. Results Sustained viral response (SVR) was achieved in 13 patients with a mean baseline LV/kg of 0.022 (SD 0.004) L/kg. At the end of treatment, the mean LV/kg was 0.025 (SD 0.004, P = 0.024 cf baseline LV/kg) and 0.026 (SD 0.004, P = 0.008 cf baseline LV/kg) 6 months post-treatment (P = 0.030 cf baseline, P = 0.004). Body weight-corrected end of treatment LV change was significantly higher in patients with SVR compared to patients not attaining SVR (P = 0.050). End of treatment LV change was correlated to initial ALT (R2 = 0.479, P = 0.037), but not APRI, AST, viral load or liver stiffness measurements. There was a correlation of 0.89 between observers for measured slice thickness. Conclusions LV increased during anti-viral treatment, while the body weight-corrected LV increase persisted post-antiviral therapy and was larger in patients with SVR. PMID:27194891

  10. Focused and Corrective Feedback Versus Structured and Supported Debriefing in a Simulation-Based Cardiac Arrest Team Training: A Pilot Randomized Controlled Study.

    PubMed

    Kim, Ji-Hoon; Kim, Young-Min; Park, Seong Heui; Ju, Eun A; Choi, Se Min; Hong, Tai Yong

    2017-06-01

    The aim of the study was to compare the educational impact of two postsimulation debriefing methods-focused and corrective feedback (FCF) versus Structured and Supported Debriefing (SSD)-on team dynamics in simulation-based cardiac arrest team training. This was a pilot randomized controlled study conducted at a simulation center. Fourth-year medical students were randomly assigned to the FCF or SSD group, with each team composed of six students and a confederate. Each team participated in two simulations and the assigned debriefing (FCF or SSD) sessions and then underwent a test simulation. Two trained raters blindly assessed all of the recorded simulations using checklists. The primary outcome was the improvement in team dynamics scores between baseline and test simulation. The secondary outcomes were improvements before and after training in team clinical performance scores, self-assessed comprehension of and confidence in cardiac arrest management and team dynamics, as well as evaluations of the postsimulation debriefing intervention. In total, 95 students participated [FCF (8 teams, n = 47) and SSD (8 teams, n = 48)]. The SSD team dynamics score during the test simulation was higher than at baseline [baseline: 74.5 (65.9-80.9), test: 85.0 (71.9-87.6), P = 0.035]. However, there were no differences in the improvement in the team dynamics or team clinical performance scores between the two groups (P = 0.328, respectively). There was no significant difference in improvement in team dynamics scores during the test simulation compared with baseline between the SSD and FCF groups in a simulation-based cardiac arrest team training in fourth-year Korean medical students.

  11. Best (but oft-forgotten) practices: the multiple problems of multiplicity-whether and how to correct for many statistical tests.

    PubMed

    Streiner, David L

    2015-10-01

    Testing many null hypotheses in a single study results in an increased probability of detecting a significant finding just by chance (the problem of multiplicity). Debates have raged over many years with regard to whether to correct for multiplicity and, if so, how it should be done. This article first discusses how multiple tests lead to an inflation of the α level, then explores the following different contexts in which multiplicity arises: testing for baseline differences in various types of studies, having >1 outcome variable, conducting statistical tests that produce >1 P value, taking multiple "peeks" at the data, and unplanned, post hoc analyses (i.e., "data dredging," "fishing expeditions," or "P-hacking"). It then discusses some of the methods that have been proposed for correcting for multiplicity, including single-step procedures (e.g., Bonferroni); multistep procedures, such as those of Holm, Hochberg, and Šidák; false discovery rate control; and resampling approaches. Note that these various approaches describe different aspects and are not necessarily mutually exclusive. For example, resampling methods could be used to control the false discovery rate or the family-wise error rate (as defined later in this article). However, the use of one of these approaches presupposes that we should correct for multiplicity, which is not universally accepted, and the article presents the arguments for and against such "correction." The final section brings together these threads and presents suggestions with regard to when it makes sense to apply the corrections and how to do so. © 2015 American Society for Nutrition.

  12. Goal-directed transthoracic echocardiography during advanced cardiac life support: A pilot study using simulation to assess ability

    PubMed Central

    Greenstein, Yonatan Y.; Martin, Thomas J.; Rolnitzky, Linda; Felner, Kevin; Kaufman, Brian

    2015-01-01

    Introduction Goal-directed echocardiography (GDE) is used to answer specific clinical questions which provide invaluable information to physicians managing a hemodynamically unstable patient. We studied perception and ability of housestaff previously trained in GDE to accurately diagnose common causes of cardiac arrest during simulated advanced cardiac life support (ACLS); we compared their results to those of expert echocardiographers. Methods Eleven pulmonary and critical care medicine fellows, seven emergency medicine residents, and five cardiologists board-certified in echocardiography were enrolled. Baseline ability to acquire four transthoracic echocardiography views was assessed and participants were exposed to six simulated cardiac arrests and were asked to perform a GDE during ACLS. Housestaff performance was compared to the performance of five expert echocardiographers. Results Average baseline and scenario views by housestaff were of good or excellent quality 89% and 83% of the time, respectively. Expert average baseline and scenario views were always of good or excellent quality. Housestaff and experts made the correct diagnosis in 68% and 77% of cases, respectively. On average, participants required 1.5 pulse checks to make the correct diagnosis. 94% of housestaff perceived this study as an accurate assessment of ability. Conclusions In an ACLS compliant manner, housestaff are capable of diagnosing management altering pathologies the majority of the time and they reach similar diagnostic conclusions in the same amount of time as expert echocardiographers in a simulated cardiac arrest scenario. PMID:25932707

  13. OPTICAL COHERENCE TOMOGRAPHY BASELINE PREDICTORS FOR INITIAL BEST-CORRECTED VISUAL ACUITY RESPONSE TO INTRAVITREAL ANTI-VASCULAR ENDOTHELIAL GROWTH FACTOR TREATMENT IN EYES WITH DIABETIC MACULAR EDEMA: The CHARTRES Study.

    PubMed

    Santos, Ana R; Costa, Miguel Â; Schwartz, Christian; Alves, Dalila; Figueira, João; Silva, Rufino; Cunha-Vaz, Jose G

    2018-06-01

    To identify baseline optical coherence tomography morphologic characteristics predicting the visual response to anti-vascular endothelial growth factor therapy in diabetic macular edema. Sixty-seven patients with diabetic macular edema completed a prospective, observational study (NCT01947881-CHARTRES). All patients received monthly intravitreal injections of Lucentis for 3 months followed by PRN treatment and underwent best-corrected visual acuity measurements and spectral domain optical coherence tomography at Baseline, Months 1, 2, 3, and 6. Visual treatment response was characterized as good (≥10 letters), moderate (5-10 letters), and poor (<5 or letters loss). Spectral domain optical coherence tomography images were graded before and after treatment by a certified Reading Center. One month after loading dose, 26 patients (38.80%) were identified as good responders, 19 (28.35%) as Moderate and 22 (32.83%) as poor responders. There were no significant best-corrected visual acuity and central retinal thickness differences at baseline (P = 0.176; P = 0.573, respectively). Ellipsoid zone disruption and disorganization of retinal inner layers were good predictors for treatment response, representing a significant risk for poor visual recovery to anti-vascular endothelial growth factor therapy (odds ratio = 10.96; P < 0.001 for ellipsoid zone disruption and odds ratio = 7.05; P = 0.034 for disorganization of retinal inner layers). Damage of ellipsoid zone, higher values of disorganization of retinal inner layers, and central retinal thickness decrease are good predictors of best-corrected visual acuity response to anti-vascular endothelial growth factor therapy.

  14. Vision-Enhancing Interventions in Nursing Home Residents and Their Short-Term Impact on Physical and Cognitive Function

    PubMed Central

    Elliott, Amanda F.; McGwin, Gerald; Owsley, Cynthia

    2009-01-01

    OBJECTIVE To evaluate the effect of vision-enhancing interventions (i.e., cataract surgery or refractive error correction) on physical function and cognitive status in nursing home residents. DESIGN Longitudinal cohort study. SETTING Seventeen nursing homes in Birmingham, AL. PARTICIPANTS A total of 187 English-speaking older adults (>55 years of age). INTERVENTION Participants took part in one of two vision-enhancing interventions: cataract surgery or refractive error correction. Each group was compared against a control group (persons eligible for but who declined cataract surgery, or who received delayed correction of refractive error). MEASUREMENTS Physical function (i.e., ability to perform activities of daily living and mobility) was assessed with a series of self-report and certified nursing assistant ratings at baseline and at 2 months for the refractive error correction group, and at 4 months for the cataract surgery group. The Mini Mental State Exam was also administered. RESULTS No significant differences existed within or between groups from baseline to follow-up on any of the measures of physical function. Mental status scores significantly declined from baseline to follow-up for both the immediate (p= 0.05) and delayed (p< 0.02) refractive error correction groups and for the cataract surgery control group (p= 0.05). CONCLUSION Vision-enhancing interventions did not lead to short-term improvements in physical functioning or cognitive status in this sample of elderly nursing home residents. PMID:19170783

  15. Vesicular and non-vesicular glutamate release in the nucleus accumbens in conditions of a forced change of behavioral strategy.

    PubMed

    Saul'skaya, N B; Mikhailova, M O

    2005-09-01

    Studies on Sprague-Dawley rats used intracerebral dialysis and high-performance liquid chromatography to identify sources of glutamate release into the intercellular space of the nucleus accumbens during forced correction of food-related behavior, i.e., on presentation to the feeding rat of a conditioned signal previously combined with a pain stimulus or on replacement of a food reinforcement with an inedible food substitute. The results showed that glutamate release observed in the nucleus accumbens during these tests can be prevented by tetrodotoxin (1 microM), which blocks exocytosis, but not by (S)-4-carboxyphenylglycine (5 microM), which blocks non-vesicular glutamate release. Conversely, administration of (S)-4-carboxyphenylglycine halved baseline glutamate release, while administration of tetrodotoxin had no effect on this process. These data provide evidence that different mechanisms control glutamate release into the intercellular space of this nucleus in baseline conditions and in conditions of evoked correction of feeding behavior: the source of baseline glutamate release is non-vesicular glutamate release, while glutamate release seen during forced correction of feeding behavior results from increases in synaptic release.

  16. TH-A-18C-09: Ultra-Fast Monte Carlo Simulation for Cone Beam CT Imaging of Brain Trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisniega, A; Zbijewski, W; Stayman, J

    Purpose: Application of cone-beam CT (CBCT) to low-contrast soft tissue imaging, such as in detection of traumatic brain injury, is challenged by high levels of scatter. A fast, accurate scatter correction method based on Monte Carlo (MC) estimation is developed for application in high-quality CBCT imaging of acute brain injury. Methods: The correction involves MC scatter estimation executed on an NVIDIA GTX 780 GPU (MC-GPU), with baseline simulation speed of ~1e7 photons/sec. MC-GPU is accelerated by a novel, GPU-optimized implementation of variance reduction (VR) techniques (forced detection and photon splitting). The number of simulated tracks and projections is reduced formore » additional speed-up. Residual noise is removed and the missing scatter projections are estimated via kernel smoothing (KS) in projection plane and across gantry angles. The method is assessed using CBCT images of a head phantom presenting a realistic simulation of fresh intracranial hemorrhage (100 kVp, 180 mAs, 720 projections, source-detector distance 700 mm, source-axis distance 480 mm). Results: For a fixed run-time of ~1 sec/projection, GPU-optimized VR reduces the noise in MC-GPU scatter estimates by a factor of 4. For scatter correction, MC-GPU with VR is executed with 4-fold angular downsampling and 1e5 photons/projection, yielding 3.5 minute run-time per scan, and de-noised with optimized KS. Corrected CBCT images demonstrate uniformity improvement of 18 HU and contrast improvement of 26 HU compared to no correction, and a 52% increase in contrast-tonoise ratio in simulated hemorrhage compared to “oracle” constant fraction correction. Conclusion: Acceleration of MC-GPU achieved through GPU-optimized variance reduction and kernel smoothing yields an efficient (<5 min/scan) and accurate scatter correction that does not rely on additional hardware or simplifying assumptions about the scatter distribution. The method is undergoing implementation in a novel CBCT dedicated to brain trauma imaging at the point of care in sports and military applications. Research grant from Carestream Health. JY is an employee of Carestream Health.« less

  17. Applying the intention-to-treat principle in practice: Guidance on handling randomisation errors

    PubMed Central

    Sullivan, Thomas R; Voysey, Merryn; Lee, Katherine J; Cook, Jonathan A; Forbes, Andrew B

    2015-01-01

    Background: The intention-to-treat principle states that all randomised participants should be analysed in their randomised group. The implications of this principle are widely discussed in relation to the analysis, but have received limited attention in the context of handling errors that occur during the randomisation process. The aims of this article are to (1) demonstrate the potential pitfalls of attempting to correct randomisation errors and (2) provide guidance on handling common randomisation errors when they are discovered that maintains the goals of the intention-to-treat principle. Methods: The potential pitfalls of attempting to correct randomisation errors are demonstrated and guidance on handling common errors is provided, using examples from our own experiences. Results: We illustrate the problems that can occur when attempts are made to correct randomisation errors and argue that documenting, rather than correcting these errors, is most consistent with the intention-to-treat principle. When a participant is randomised using incorrect baseline information, we recommend accepting the randomisation but recording the correct baseline data. If ineligible participants are inadvertently randomised, we advocate keeping them in the trial and collecting all relevant data but seeking clinical input to determine their appropriate course of management, unless they can be excluded in an objective and unbiased manner. When multiple randomisations are performed in error for the same participant, we suggest retaining the initial randomisation and either disregarding the second randomisation if only one set of data will be obtained for the participant, or retaining the second randomisation otherwise. When participants are issued the incorrect treatment at the time of randomisation, we propose documenting the treatment received and seeking clinical input regarding the ongoing treatment of the participant. Conclusion: Randomisation errors are almost inevitable and should be reported in trial publications. The intention-to-treat principle is useful for guiding responses to randomisation errors when they are discovered. PMID:26033877

  18. Effects of correcting for prematurity on cognitive test scores in childhood.

    PubMed

    Wilson-Ching, Michelle; Pascoe, Leona; Doyle, Lex W; Anderson, Peter J

    2014-03-01

    The American Academy of Pediatrics recommends that test scores should be corrected for prematurity up to 3 years of age, but this practice varies greatly in both clinical and research settings. The aim of this study was to contrast the effects of using chronological age and those of using corrected age on measures of cognitive outcome across childhood. A theoretical model was constructed using norms from the Bayley Scales of Infant and Toddler Development, Third Edition; the Wechsler Preschool and Primary Scale of Intelligence, Third Edition Australian; and the Wechsler Intelligence Scales for Children, Fourth Edition Australian. Baseline scores representing different levels of functioning (70, below average; 85, borderline; and 100, average) were recalculated using the normative data for ages 6 months to 16 years to account for 1, 2, 3 and 4 months of prematurity. The model created depicted the difference in standardised scores between chronological and corrected age. Compared with scores corrected for prematurity, the absolute reduction in scores using chronological age was greater for increasing degree of prematurity, younger ages at assessment and higher baseline scores and was substantial even beyond 3 years of age. However, the pattern was erratic, with considerable fluctuation evident across different ages and baseline scores. Chronological age results in a lowering of scores at all ages for preterm-born subjects that is greater in the first few years and in those born at earlier gestational ages. Whether or not to correct for prematurity depends upon the context of the assessment. © 2014 The Authors. Journal of Paediatrics and Child Health © 2014 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  19. Inhaler technique maintenance: gaining an understanding from the patient's perspective.

    PubMed

    Ovchinikova, Ludmila; Smith, Lorraine; Bosnic-Anticevich, Sinthia

    2011-08-01

    The aim of this study was to determine the patient-, education-, and device-related factors that predict inhaler technique maintenance. Thirty-one community pharmacists were trained to deliver inhaler technique education to people with asthma. Pharmacists evaluated (based on published checklists), and where appropriate, delivered inhaler technique education to patients (participants) in the community pharmacy at baseline (Visit 1) and 1 month later (Visit 2). Data were collected on participant demographics, asthma history, current asthma control, history of inhaler technique education, and a range of psychosocial aspects of disease management (including adherence to medication, motivation for correct technique, beliefs regarding the importance of maintaining correct technique, and necessity and concern beliefs regarding preventer therapy). Stepwise backward logistic regression was used to identify the predictors of inhaler technique maintenance at 1 month. In total 145 and 127 participants completed Visits 1 and 2, respectively. At baseline, 17% of patients (n = 24) demonstrated correct technique (score 11/11) which increased to 100% (n = 139) after remedial education by pharmacists. At follow-up, 61% (n = 77) of patients demonstrated correct technique. The predictors of inhaler technique maintenance based on the logistic regression model (X(2) (3, N = 125) = 16.22, p = .001) were use of a dry powder inhaler over a pressurized metered-dose inhaler (OR 2.6), having better asthma control at baseline (OR 2.3), and being more motivated to practice correct inhaler technique (OR 1.2). Contrary to what is typically recommended in previous research, correct inhaler technique maintenance may involve more than repetition of instructions. This study found that past technique education factors had no bearing on technique maintenance, whereas patient psychosocial factors (motivation) did.

  20. Statistical bias correction method applied on CMIP5 datasets over the Indian region during the summer monsoon season for climate change applications

    NASA Astrophysics Data System (ADS)

    Prasanna, V.

    2018-01-01

    This study makes use of temperature and precipitation from CMIP5 climate model output for climate change application studies over the Indian region during the summer monsoon season (JJAS). Bias correction of temperature and precipitation from CMIP5 GCM simulation results with respect to observation is discussed in detail. The non-linear statistical bias correction is a suitable bias correction method for climate change data because it is simple and does not add up artificial uncertainties to the impact assessment of climate change scenarios for climate change application studies (agricultural production changes) in the future. The simple statistical bias correction uses observational constraints on the GCM baseline, and the projected results are scaled with respect to the changing magnitude in future scenarios, varying from one model to the other. Two types of bias correction techniques are shown here: (1) a simple bias correction using a percentile-based quantile-mapping algorithm and (2) a simple but improved bias correction method, a cumulative distribution function (CDF; Weibull distribution function)-based quantile-mapping algorithm. This study shows that the percentile-based quantile mapping method gives results similar to the CDF (Weibull)-based quantile mapping method, and both the methods are comparable. The bias correction is applied on temperature and precipitation variables for present climate and future projected data to make use of it in a simple statistical model to understand the future changes in crop production over the Indian region during the summer monsoon season. In total, 12 CMIP5 models are used for Historical (1901-2005), RCP4.5 (2005-2100), and RCP8.5 (2005-2100) scenarios. The climate index from each CMIP5 model and the observed agricultural yield index over the Indian region are used in a regression model to project the changes in the agricultural yield over India from RCP4.5 and RCP8.5 scenarios. The results revealed a better convergence of model projections in the bias corrected data compared to the uncorrected data. The study can be extended to localized regional domains aimed at understanding the changes in the agricultural productivity in the future with an agro-economy or a simple statistical model. The statistical model indicated that the total food grain yield is going to increase over the Indian region in the future, the increase in the total food grain yield is approximately 50 kg/ ha for the RCP4.5 scenario from 2001 until the end of 2100, and the increase in the total food grain yield is approximately 90 kg/ha for the RCP8.5 scenario from 2001 until the end of 2100. There are many studies using bias correction techniques, but this study applies the bias correction technique to future climate scenario data from CMIP5 models and applied it to crop statistics to find future crop yield changes over the Indian region.

  1. Respiratory sinus arrhythmia responses to induced emotional states: effects of RSA indices, emotion induction method, age, and sex.

    PubMed

    Overbeek, Thérèse J M; van Boxtel, Anton; Westerink, Joyce H D M

    2012-09-01

    The literature shows large inconsistencies in respiratory sinus arrhythmia (RSA) responses to induced emotional states. This may be caused by differences in emotion induction methods, RSA quantification, and non-emotional demands of the situation. In 83 healthy subjects, we studied RSA responses to pictures and film fragments eliciting six different discrete emotions relative to neutral baseline stimuli. RSA responses were quantified in the time and frequency domain and were additionally corrected for differences in mean heart rate and respiration rate, resulting in eight different RSA response measures. Subjective ratings of emotional stimuli and facial electromyographic responses indicated that pictures and film fragments elicited the intended emotions. Although RSA measures showed various emotional effects, responses were quite heterogeneous and frequently nonsignificant. They were substantially influenced by methodological factors, in particular time vs. frequency domain response measures, correction for changes in respiration rate, use of pictures vs. film fragments, and sex of participants. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Automatic Analysis of Pronunciations for Children with Speech Sound Disorders.

    PubMed

    Dudy, Shiran; Bedrick, Steven; Asgari, Meysam; Kain, Alexander

    2018-07-01

    Computer-Assisted Pronunciation Training (CAPT) systems aim to help a child learn the correct pronunciations of words. However, while there are many online commercial CAPT apps, there is no consensus among Speech Language Therapists (SLPs) or non-professionals about which CAPT systems, if any, work well. The prevailing assumption is that practicing with such programs is less reliable and thus does not provide the feedback necessary to allow children to improve their performance. The most common method for assessing pronunciation performance is the Goodness of Pronunciation (GOP) technique. Our paper proposes two new GOP techniques. We have found that pronunciation models that use explicit knowledge about error pronunciation patterns can lead to more accurate classification whether a phoneme was correctly pronounced or not. We evaluate the proposed pronunciation assessment methods against a baseline state of the art GOP approach, and show that the proposed techniques lead to classification performance that is more similar to that of a human expert.

  3. The Spring 1985 high precision baseline test of the JPL GPS-based geodetic system

    NASA Technical Reports Server (NTRS)

    Davidson, John M.; Thornton, Catherine L.; Stephens, Scott A.; Blewitt, Geoffrey; Lichten, Stephen M.; Sovers, Ojars J.; Kroger, Peter M.; Skrumeda, Lisa L.; Border, James S.; Neilan, Ruth E.

    1987-01-01

    The Spring 1985 High Precision Baseline Test (HPBT) was conducted. The HPBT was designed to meet a number of objectives. Foremost among these was the demonstration of a level of accuracy of 1 to 2:10 to the 7th power, or better, for baselines ranging in length up to several hundred kilometers. These objectives were all met with a high degree of success, with respect to the demonstration of system accuracy in particular. The results from six baselines ranging in length from 70 to 729 km were examined for repeatability and, in the case of three baselines, were compared to results from colocated VLBI systems. Repeatability was found to be 5:10 to the 8th power (RMS) for the north baseline coordinate, independent of baseline length, while for the east coordinate RMS repeatability was found to be larger than this by factors of 2 to 4. The GPS-based results were found to be in agreement with those from colocated VLBI measurements, when corrected for the physical separations of the VLBI and CPG antennas, at the level of 1 to 2:10 to the 7th power in all coordinates, independent of baseline length. The results for baseline repeatability are consistent with the current GPA error budget, but the GPS-VLBI intercomparisons disagree at a somewhat larger level than expected. It is hypothesized that these differences may result from errors in the local survey measurements used to correct for the separations of the GPS and VLBI antenna reference centers.

  4. Methods for the correction of vascular artifacts in PET O-15 water brain-mapping studies

    NASA Astrophysics Data System (ADS)

    Chen, Kewei; Reiman, E. M.; Lawson, M.; Yun, Lang-sheng; Bandy, D.; Palant, A.

    1996-12-01

    While positron emission tomographic (PET) measurements of regional cerebral blood flow (rCBF) can be used to map brain regions that are involved in normal and pathological human behaviors, measurements in the anteromedial temporal lobe can be confounded by the combined effects of radiotracer activity in neighboring arteries and partial-volume averaging. The authors now describe two simple methods to address this vascular artifact. One method utilizes the early frames of a dynamic PET study, while the other method utilizes a coregistered magnetic resonance image (MRI) to characterize the vascular region of interest (VROI). Both methods subsequently assign a common value to each pixel in the VROI for the control (baseline) scan and the activation scan. To study the vascular artifact and to demonstrate the ability of the proposed methods correcting the vascular artifact, four dynamic PET scans were performed in a single subject during the same behavioral state. For each of the four scans, a vascular scan containing vascular activity was computed as the summation of the images acquired 0-60 s after radiotracer administration, and a control scan containing minimal vascular activity was computed as the summation of the images acquired 20-80 s after radiotracer administration. t-score maps calculated from the four pairs of vascular and control scans were used to characterize regional blood flow differences related to vascular activity before and after the application of each vascular artifact correction method. Both methods eliminated the observed differences in vascular activity, as well as the vascular artifact observed in the anteromedial temporal lobes. Using PET data from a study of normal human emotion, these methods permitted the authors to identify rCBF increases in the anteromedial temporal lobe free from the potentially confounding, combined effects of vascular activity and partial-volume averaging.

  5. The selection of the optimal baseline in the front-view monocular vision system

    NASA Astrophysics Data System (ADS)

    Xiong, Bincheng; Zhang, Jun; Zhang, Daimeng; Liu, Xiaomao; Tian, Jinwen

    2018-03-01

    In the front-view monocular vision system, the accuracy of solving the depth field is related to the length of the inter-frame baseline and the accuracy of image matching result. In general, a longer length of the baseline can lead to a higher precision of solving the depth field. However, at the same time, the difference between the inter-frame images increases, which increases the difficulty in image matching and the decreases matching accuracy and at last may leads to the failure of solving the depth field. One of the usual practices is to use the tracking and matching method to improve the matching accuracy between images, but this algorithm is easy to cause matching drift between images with large interval, resulting in cumulative error in image matching, and finally the accuracy of solving the depth field is still very low. In this paper, we propose a depth field fusion algorithm based on the optimal length of the baseline. Firstly, we analyze the quantitative relationship between the accuracy of the depth field calculation and the length of the baseline between frames, and find the optimal length of the baseline by doing lots of experiments; secondly, we introduce the inverse depth filtering technique for sparse SLAM, and solve the depth field under the constraint of the optimal length of the baseline. By doing a large number of experiments, the results show that our algorithm can effectively eliminate the mismatch caused by image changes, and can still solve the depth field correctly in the large baseline scene. Our algorithm is superior to the traditional SFM algorithm in time and space complexity. The optimal baseline obtained by a large number of experiments plays a guiding role in the calculation of the depth field in front-view monocular.

  6. Web Server for Peak Detection, Baseline Correction, and Alignment in Two-Dimensional Gas Chromatography Mass Spectrometry-Based Metabolomics Data.

    PubMed

    Tian, Tze-Feng; Wang, San-Yuan; Kuo, Tien-Chueh; Tan, Cheng-En; Chen, Guan-Yuan; Kuo, Ching-Hua; Chen, Chi-Hsin Sally; Chan, Chang-Chuan; Lin, Olivia A; Tseng, Y Jane

    2016-11-01

    Two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC/TOF-MS) is superior for chromatographic separation and provides great sensitivity for complex biological fluid analysis in metabolomics. However, GC×GC/TOF-MS data processing is currently limited to vendor software and typically requires several preprocessing steps. In this work, we implement a web-based platform, which we call GC 2 MS, to facilitate the application of recent advances in GC×GC/TOF-MS, especially for metabolomics studies. The core processing workflow of GC 2 MS consists of blob/peak detection, baseline correction, and blob alignment. GC 2 MS treats GC×GC/TOF-MS data as pictures and clusters the pixels as blobs according to the brightness of each pixel to generate a blob table. GC 2 MS then aligns the blobs of two GC×GC/TOF-MS data sets according to their distance and similarity. The blob distance and similarity are the Euclidean distance of the first and second retention times of two blobs and the Pearson's correlation coefficient of the two mass spectra, respectively. GC 2 MS also directly corrects the raw data baseline. The analytical performance of GC 2 MS was evaluated using GC×GC/TOF-MS data sets of Angelica sinensis compounds acquired under different experimental conditions and of human plasma samples. The results show that GC 2 MS is an easy-to-use tool for detecting peaks and correcting baselines, and GC 2 MS is able to align GC×GC/TOF-MS data sets acquired under different experimental conditions. GC 2 MS is freely accessible at http://gc2ms.web.cmdm.tw .

  7. The effect of multifocal soft contact lenses on peripheral refraction.

    PubMed

    Kang, Pauline; Fan, Yvonne; Oh, Kelly; Trac, Kevin; Zhang, Frank; Swarbrick, Helen A

    2013-07-01

    To compare changes in peripheral refraction with single-vision (SV) and multifocal (MF) correction of distance central refraction with commercially available SV and MF soft contact lenses (SCLs) in young myopic adults. Thirty-four myopic adult subjects were fitted with Proclear Sphere and Proclear Multifocal SCLs to correct their manifest central refractive error. Central and peripheral refraction were measured with no lens wear and subsequently with the two different types of SCL correction. At baseline, refraction was myopic at all locations along the horizontal meridian. Peripheral refraction was relatively hyperopic compared with center at 30 and 35 degrees in the temporal visual field (VF) in low myopes, and at 30 and 35 degrees in the temporal VF, and 10, 30, and 35 degrees in the nasal VF in moderate myopes. Single-vision and MF distance correction with Proclear Sphere and Proclear Multifocal SCLs, respectively, caused a hyperopic shift in refraction at all locations in the horizontal VF. Compared with SV correction, MF SCL correction caused a significant relative myopic shift at all locations in the nasal VF in both low and moderate myopes and also at 35 degrees in the temporal VF in moderate myopes. Correction of central refractive error with SV and MF SCLs caused a hyperopic shift in both central and peripheral refraction at all positions in the horizontal meridian. Single-vision SCL correction caused the peripheral retina, which initially experienced absolute myopic defocus at baseline with no correction to experience an absolute hyperopic defocus. Multifocal SCL correction resulted in a relative myopic shift in peripheral refraction compared with SV SCL correction. This myopic shift may explain recent reports of reduced myopia progression rates with MF SCL correction.

  8. 75 FR 28599 - Acacia Natural Gas Corporation; Notice of Baseline Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-21

    ... Natural Gas Corporation (Acacia) submitted a corrected baseline filing of its Statement of Operating Conditions for the interruptible transportation services provided under section 311(a)(2) of the Natural Gas... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-16-002] Acacia Natural...

  9. Toward Baseline Software Anomalies in NASA Missions

    NASA Technical Reports Server (NTRS)

    Layman, Lucas; Zelkowitz, Marvin; Basili, Victor; Nikora, Allen P.

    2012-01-01

    In this fast abstract, we provide preliminary findings an analysis of 14,500 spacecraft anomalies from unmanned NASA missions. We provide some baselines for the distributions of software vs. non-software anomalies in spaceflight systems, the risk ratings of software anomalies, and the corrective actions associated with software anomalies.

  10. [Experimental research of turbidity influence on water quality monitoring of COD in UV-visible spectroscopy].

    PubMed

    Tang, Bin; Wei, Biao; Wu, De-Cao; Mi, De-Ling; Zhao, Jing-Xiao; Feng, Peng; Jiang, Shang-Hai; Mao, Ben-Jiang

    2014-11-01

    Eliminating turbidity is a direct effect spectroscopy detection of COD key technical problems. This stems from the UV-visible spectroscopy detected key quality parameters depend on an accurate and effective analysis of water quality parameters analytical model, and turbidity is an important parameter that affects the modeling. In this paper, we selected formazine turbidity solution and standard solution of potassium hydrogen phthalate to study the turbidity affect of UV--visible absorption spectroscopy detection of COD, at the characteristics wavelength of 245, 300, 360 and 560 nm wavelength point several characteristics with the turbidity change in absorbance method of least squares curve fitting, thus analyzes the variation of absorbance with turbidity. The results show, In the ultraviolet range of 240 to 380 nm, as the turbidity caused by particle produces compounds to the organics, it is relatively complicated to test the turbidity affections on the water Ultraviolet spectra; in the visible region of 380 to 780 nm, the turbidity of the spectrum weakens with wavelength increases. Based on this, this paper we study the multiplicative scatter correction method affected by the turbidity of the water sample spectra calibration test, this method can correct water samples spectral affected by turbidity. After treatment, by comparing the spectra before, the results showed that the turbidity caused by wavelength baseline shift points have been effectively corrected, and features in the ultraviolet region has not diminished. Then we make multiplicative scatter correction for the three selected UV liquid-visible absorption spectroscopy, experimental results shows that on the premise of saving the characteristic of the Ultraviolet-Visible absorption spectrum of water samples, which not only improve the quality of COD spectroscopy detection SNR, but also for providing an efficient data conditioning regimen for establishing an accurate of the chemical measurement methods.

  11. Analysing and correcting the differences between multi-source and multi-scale spatial remote sensing observations.

    PubMed

    Dong, Yingying; Luo, Ruisen; Feng, Haikuan; Wang, Jihua; Zhao, Jinling; Zhu, Yining; Yang, Guijun

    2014-01-01

    Differences exist among analysis results of agriculture monitoring and crop production based on remote sensing observations, which are obtained at different spatial scales from multiple remote sensors in same time period, and processed by same algorithms, models or methods. These differences can be mainly quantitatively described from three aspects, i.e. multiple remote sensing observations, crop parameters estimation models, and spatial scale effects of surface parameters. Our research proposed a new method to analyse and correct the differences between multi-source and multi-scale spatial remote sensing surface reflectance datasets, aiming to provide references for further studies in agricultural application with multiple remotely sensed observations from different sources. The new method was constructed on the basis of physical and mathematical properties of multi-source and multi-scale reflectance datasets. Theories of statistics were involved to extract statistical characteristics of multiple surface reflectance datasets, and further quantitatively analyse spatial variations of these characteristics at multiple spatial scales. Then, taking the surface reflectance at small spatial scale as the baseline data, theories of Gaussian distribution were selected for multiple surface reflectance datasets correction based on the above obtained physical characteristics and mathematical distribution properties, and their spatial variations. This proposed method was verified by two sets of multiple satellite images, which were obtained in two experimental fields located in Inner Mongolia and Beijing, China with different degrees of homogeneity of underlying surfaces. Experimental results indicate that differences of surface reflectance datasets at multiple spatial scales could be effectively corrected over non-homogeneous underlying surfaces, which provide database for further multi-source and multi-scale crop growth monitoring and yield prediction, and their corresponding consistency analysis evaluation.

  12. Analysing and Correcting the Differences between Multi-Source and Multi-Scale Spatial Remote Sensing Observations

    PubMed Central

    Dong, Yingying; Luo, Ruisen; Feng, Haikuan; Wang, Jihua; Zhao, Jinling; Zhu, Yining; Yang, Guijun

    2014-01-01

    Differences exist among analysis results of agriculture monitoring and crop production based on remote sensing observations, which are obtained at different spatial scales from multiple remote sensors in same time period, and processed by same algorithms, models or methods. These differences can be mainly quantitatively described from three aspects, i.e. multiple remote sensing observations, crop parameters estimation models, and spatial scale effects of surface parameters. Our research proposed a new method to analyse and correct the differences between multi-source and multi-scale spatial remote sensing surface reflectance datasets, aiming to provide references for further studies in agricultural application with multiple remotely sensed observations from different sources. The new method was constructed on the basis of physical and mathematical properties of multi-source and multi-scale reflectance datasets. Theories of statistics were involved to extract statistical characteristics of multiple surface reflectance datasets, and further quantitatively analyse spatial variations of these characteristics at multiple spatial scales. Then, taking the surface reflectance at small spatial scale as the baseline data, theories of Gaussian distribution were selected for multiple surface reflectance datasets correction based on the above obtained physical characteristics and mathematical distribution properties, and their spatial variations. This proposed method was verified by two sets of multiple satellite images, which were obtained in two experimental fields located in Inner Mongolia and Beijing, China with different degrees of homogeneity of underlying surfaces. Experimental results indicate that differences of surface reflectance datasets at multiple spatial scales could be effectively corrected over non-homogeneous underlying surfaces, which provide database for further multi-source and multi-scale crop growth monitoring and yield prediction, and their corresponding consistency analysis evaluation. PMID:25405760

  13. Controlling for anthropogenically induced atmospheric variation in stable carbon isotope studies

    USGS Publications Warehouse

    Long, E.S.; Sweitzer, R.A.; Diefenbach, D.R.; Ben-David, M.

    2005-01-01

    Increased use of stable isotope analysis to examine food-web dynamics, migration, transfer of nutrients, and behavior will likely result in expansion of stable isotope studies investigating human-induced global changes. Recent elevation of atmospheric CO2 concentration, related primarily to fossil fuel combustion, has reduced atmospheric CO2 ??13C (13C/12C), and this change in isotopic baseline has, in turn, reduced plant and animal tissue ??13C of terrestrial and aquatic organisms. Such depletion in CO2 ??13C and its effects on tissue ??13C may introduce bias into ??13C investigations, and if this variation is not controlled, may confound interpretation of results obtained from tissue samples collected over a temporal span. To control for this source of variation, we used a high-precision record of atmospheric CO2 ??13C from ice cores and direct atmospheric measurements to model modern change in CO2 ??13C. From this model, we estimated a correction factor that controls for atmospheric change; this correction reduces bias associated with changes in atmospheric isotopic baseline and facilitates comparison of tissue ??13C collected over multiple years. To exemplify the importance of accounting for atmospheric CO2 ??13C depletion, we applied the correction to a dataset of collagen ??13C obtained from mountain lion (Puma concolor) bone samples collected in California between 1893 and 1995. Before correction, in three of four ecoregions collagen ??13C decreased significantly concurrent with depletion of atmospheric CO2 ??13C (n ??? 32, P ??? 0.01). Application of the correction to collagen ??13C data removed trends from regions demonstrating significant declines, and measurement error associated with the correction did not add substantial variation to adjusted estimates. Controlling for long-term atmospheric variation and correcting tissue samples for changes in isotopic baseline facilitate analysis of samples that span a large temporal range. ?? Springer-Verlag 2005.

  14. Persistent aerial video registration and fast multi-view mosaicing.

    PubMed

    Molina, Edgardo; Zhu, Zhigang

    2014-05-01

    Capturing aerial imagery at high resolutions often leads to very low frame rate video streams, well under full motion video standards, due to bandwidth, storage, and cost constraints. Low frame rates make registration difficult when an aircraft is moving at high speeds or when global positioning system (GPS) contains large errors or it fails. We present a method that takes advantage of persistent cyclic video data collections to perform an online registration with drift correction. We split the persistent aerial imagery collection into individual cycles of the scene, identify and correct the registration errors on the first cycle in a batch operation, and then use the corrected base cycle as a reference pass to register and correct subsequent passes online. A set of multi-view panoramic mosaics is then constructed for each aerial pass for representation, presentation and exploitation of the 3D dynamic scene. These sets of mosaics are all in alignment to the reference cycle allowing their direct use in change detection, tracking, and 3D reconstruction/visualization algorithms. Stereo viewing with adaptive baselines and varying view angles is realized by choosing a pair of mosaics from a set of multi-view mosaics. Further, the mosaics for the second pass and later can be generated and visualized online as their is no further batch error correction.

  15. Classical least squares multivariate spectral analysis

    DOEpatents

    Haaland, David M.

    2002-01-01

    An improved classical least squares multivariate spectral analysis method that adds spectral shapes describing non-calibrated components and system effects (other than baseline corrections) present in the analyzed mixture to the prediction phase of the method. These improvements decrease or eliminate many of the restrictions to the CLS-type methods and greatly extend their capabilities, accuracy, and precision. One new application of PACLS includes the ability to accurately predict unknown sample concentrations when new unmodeled spectral components are present in the unknown samples. Other applications of PACLS include the incorporation of spectrometer drift into the quantitative multivariate model and the maintenance of a calibration on a drifting spectrometer. Finally, the ability of PACLS to transfer a multivariate model between spectrometers is demonstrated.

  16. High-precision GNSS ocean positioning with BeiDou short-message communication

    NASA Astrophysics Data System (ADS)

    Li, Bofeng; Zhang, Zhiteng; Zang, Nan; Wang, Siyao

    2018-04-01

    The current popular GNSS RTK technique would be not applicable on ocean due to the limited communication access for transmitting differential corrections. A new technique is proposed for high-precision ocean RTK, referred to as ORTK, where the corrections are transmitted by employing the function of BeiDou satellite short-message communication (SMC). To overcome the limitation of narrow bandwidth of BeiDou SMC, a new strategy of simplifying and encoding corrections is proposed instead of standard differential corrections, which reduces the single-epoch corrections from more than 1000 to less than 300 bytes. To solve the problems of correction delays, cycle slips, blunders and abnormal epochs over ultra-long baseline ORTK, a series of powerful algorithms were designed at the user-end software for achieving the stable and precise kinematic solutions on far ocean applications. The results from two long baselines of 240 and 420 km and real ocean experiments reveal that the kinematic solutions with horizontal accuracy of 5 cm and vertical accuracy of better than 15 cm are achievable by convergence time of 3-10 min. Compared to commercial ocean PPP with satellite telecommunication, ORTK is of much cheaper expense, higher accuracy and shorter convergence. It will be very prospective in many location-based ocean services.

  17. Determination of iprodione in agrochemicals by infrared and Raman spectrometry.

    PubMed

    Armenta, Sergio; Garrigues, Salvador; de la Guardia, Miguel

    2007-04-01

    Two methodologies based on vibrational spectrometry--making use of Fourier transform infrared absorption (FTIR) and Raman spectrometry--were developed for iprodione determination in solid pesticide formulations. The FTIR procedure involved the extraction of iprodione by CHCl(3), and the latter determination involved measuring the peak area between 1450 and 1440 cm(-1), corrected using a horizontal baseline defined at 1481 cm(-1). FT-Raman determination was performed directly on the powdered solid products, using standard chromatography glass vials as sample cells and measuring the Raman intensity between 1003 and 993 cm(-1), with a two-point baseline correction established between 1012 and 981 cm(-1). The sensitivities obtained were 0.319 area values g mg(-1) for FTIR determination and 5.58 area values g g(-1) for FT-Raman. The repeatabilities, taken to be the relative standard deviation of five independent measurements at 1.51 mg g(-1) and 10.98% w/w concentration levels, were equal to 0.16% and 0.9% for FTIR and FT-Raman, respectively, and the limits of detection were 0.3 and 0.2% w/w (higher than those obtained for HPLC, 0.016% w/w). FTIR determination provided a sample frequency of 60 h(-1), higher than those obtained for the Raman and reference chromatography methods (25 and 8.6 h(-1), respectively). On the other hand, the new FT-Raman method eliminates reagent consumption and waste generation, and reduces the need for sample handling and the contact of operator with the pesticide. In spite of their lack of sensitivity, vibrational procedures can therefore provide viable environmentally friendly alternatives to laborious, time- and solvent-consuming reference chromatography methods for quality control in commercially available pesticide formulations.

  18. Correction to: Regional differences in baseline disease activity and remission rates following golimumab treatment for RA: results from the GO-MORE trial.

    PubMed

    Durez, Patrick; Pavelka, Karel; Lazaro, Maria Alicia; Garcia-Kutzbach, Abraham; Moots, Robert J; Amital, Howard; Govoni, Marinella; Vastesaeger, Nathan

    2018-05-12

    The original publication contains two areas which require correcting. None of these errors change the results or conclusions of the article, but the authors wish to highlight the areas of change to the reader.

  19. Individualized correction of insulin measurement in hemolyzed serum samples.

    PubMed

    Wu, Zhi-Qi; Lu, Ju; Chen, Huanhuan; Chen, Wensen; Xu, Hua-Guo

    2017-06-01

    Insulin measurement plays a key role in the investigation of patients with hypoglycemia, subtype classification of diabetes mellitus, insulin resistance, and impaired beta cell function. However, even slight hemolysis can negatively affect insulin measurement due to RBC insulin-degrading enzyme (IDE). Here, we derived and validated an individualized correction equation in an attempt to eliminate the effects of hemolysis on insulin measurement. The effects of hemolysis on insulin measurement were studied by adding lysed self-RBCs to serum. A correction equation was derived, accounting for both percentage and exposure time of hemolysis. The performance of this individualized correction was evaluated in intentionally hemolyzed samples. Insulin concentration decreased with increasing percentage and exposure time of hemolysis. Based on the effects of hemolysis on insulin measurement of 17 donors (baseline insulin concentrations ranged from 156 to 2119 pmol/L), the individualized hemolysis correction equation was derived: INS corr  = INS meas /(0.705lgHb plasma /Hb serum  - 0.001Time - 0.612). This equation can revert insulin concentrations of the intentionally hemolyzed samples to values that were statistically not different from the corresponding insulin baseline concentrations (p = 0.1564). Hemolysis could lead to a negative interference on insulin measurement; by individualized hemolysis correction equation for insulin measurement, we can correct and report reliable serum insulin results for a wide range of degrees of sample hemolysis. This correction would increase diagnostic accuracy, reduce inappropriate therapeutic decisions, and improve patient satisfaction with care.

  20. Unsupervised pattern recognition methods in ciders profiling based on GCE voltammetric signals.

    PubMed

    Jakubowska, Małgorzata; Sordoń, Wanda; Ciepiela, Filip

    2016-07-15

    This work presents a complete methodology of distinguishing between different brands of cider and ageing degrees, based on voltammetric signals, utilizing dedicated data preprocessing procedures and unsupervised multivariate analysis. It was demonstrated that voltammograms recorded on glassy carbon electrode in Britton-Robinson buffer at pH 2 are reproducible for each brand. By application of clustering algorithms and principal component analysis visible homogenous clusters were obtained. Advanced signal processing strategy which included automatic baseline correction, interval scaling and continuous wavelet transform with dedicated mother wavelet, was a key step in the correct recognition of the objects. The results show that voltammetry combined with optimized univariate and multivariate data processing is a sufficient tool to distinguish between ciders from various brands and to evaluate their freshness. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Condom Effectiveness against Non-Viral Sexually Transmitted Infections: A Prospective Study Using Electronic Daily Diaries

    PubMed Central

    Crosby, Richard; Charnigo, Richard A.; Weathers, Chandra; Caliendo, Angela M.; Shrier, Lydia A.

    2012-01-01

    Objectives To prospectively evaluate the protective value of consistent and correct use of latex condoms against the acquisition of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis. Methods Patients (N=929) attending clinics that treat sexually transmitted infections (STIs) were prospectively followed for up to six months. Urine STI nucleic acid amplification testing was performed at baseline, three months, and six months. Participants were instructed to respond to daily prompts from a hand-held device by completing a report for each penile-vaginal sexual intercourse event. Generalized estimating equation models examined associations of consistent as well as consistent and correct condom use with STI incidence over 3-month intervals. Results Consistent condom use was not significantly associated with STI incidence (Estimated Odds Ratio [EOR]=.75; 95% confidence interval [CI]=.43-1.30; P=.31). However, individuals who used condoms both correctly and consistently were estimated to have 59% lower odds of acquiring an STI (EOR = .41; 95% CI = .19-.90; P = .026), compared to those who did not. Conclusions The correct as well as the consistent use of condoms greatly reduces the odds of non-viral STI acquisition. PMID:23002192

  2. CryoSat SAR/SARin Level1b products: assessment of BaselineC and improvements towards BaselineD

    NASA Astrophysics Data System (ADS)

    Scagliola, Michele; Fornari, Marco; Bouffard, Jerome; Parrinello, Tommaso

    2017-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. Cryosat carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. This allows to reach a significantly improved along track resolution with respect to traditional pulse-width limited altimeters. CryoSat is the first altimetry mission operating in SAR mode and continuous improvements in the Level1 Instrument Processing Facility (IPF1) are being identified, tested and validated in order to improve the quality of the Level1b products. The current IPF, Baseline C, was released in operation in April 2015 and the second CryoSat reprocessing campaign was jointly initiated, taking benefit of the upgrade implemented in the IPF1 processing chain but also of some specific configurations for the calibration corrections. In particular, the CryoSat Level1b BaselineC products generated in the framework of the second reprocessing campaign include refined information for what concerns the mispointing angles and the calibration corrections. This poster will thus detail thus the evolutions that are currently planned for the CryoSat BaselineD SAR/SARin Level1b products and the corresponding quality improvements that are expected.

  3. Effect of intravitreal bevacizumab on diabetic macular edema with hard exudates

    PubMed Central

    Jeon, Sohee; Lee, Won Ki

    2014-01-01

    Background We evaluated the efficacy of intravitreal bevacizumab on diabetic macular edema with subfoveal and perifoveal hard exudates. Materials and methods Eleven eyes (11 patients) exhibiting diabetic macular edema with subfoveal and perifoveal hard exudates were included in this prospective, nonrandomized interventional pilot study. All patients were treated with monthly scheduled intravitreal bevacizumab injections for 6 months. Changes in the Early Treatment Diabetic Retinopathy Study best corrected visual acuity, amount of hard exudates on fundus photography, and macular edema detected by central subfield thickness on spectral domain optical coherence tomography after six serial injections, were assessed. The amount of hard exudates at each visit was evaluated as pixels in fundus photography, using an Adobe Photoshop program. Results Ten of 11 patients completed follow-up. The mean Early Treatment Diabetic Retinopathy Study best corrected visual acuity was 59.9±5.7 letters (Snellen equivalent, 20/63) at baseline evaluation. The best corrected visual acuity exhibited no significant difference at month 6 compared with at baseline (57.9±6.0 letters or 20/70 at month 6; P=0.085). At month 6, mean central subfield thickness decreased from 370.4±56.5 to 334.6±65.0 μm (P=0.009). The mean amount of hard exudates increased from 4467.1±2736.1 to 6592.4±2498.3 pixels at month 6 (P=0.022). No serious adverse events occurred. Conclusion Continuous intravitreal bevacizumab was found to have no benefit in visual acuity and amount of hard exudates, despite the improvement of macular edema at 6 months. PMID:25143708

  4. Leucocyte telomere length and risk of type 2 diabetes mellitus: new prospective cohort study and literature-based meta-analysis.

    PubMed

    Willeit, Peter; Raschenberger, Julia; Heydon, Emma E; Tsimikas, Sotirios; Haun, Margot; Mayr, Agnes; Weger, Siegfried; Witztum, Joseph L; Butterworth, Adam S; Willeit, Johann; Kronenberg, Florian; Kiechl, Stefan

    2014-01-01

    Short telomeres have been linked to various age-related diseases. We aimed to assess the association of telomere length with incident type 2 diabetes mellitus (T2DM) in prospective cohort studies. Leucocyte relative telomere length (RTL) was measured using quantitative polymerase chain reaction in 684 participants of the prospective population-based Bruneck Study (1995 baseline), with repeat RTL measurements performed in 2005 (n = 558) and 2010 (n = 479). Hazard ratios for T2DM were calculated across quartiles of baseline RTL using Cox regression models adjusted for age, sex, body-mass index, smoking, socio-economic status, physical activity, alcohol consumption, high-density lipoprotein cholesterol, log high-sensitivity C-reactive protein, and waist-hip ratio. Separate analyses corrected hazard ratios for within-person variability using multivariate regression calibration of repeated measurements. To contextualise findings, we systematically sought PubMed, Web of Science and EMBASE for relevant articles and pooled results using random-effects meta-analysis. Over 15 years of follow-up, 44 out of 606 participants free of diabetes at baseline developed incident T2DM. The adjusted hazard ratio for T2DM comparing the bottom vs. the top quartile of baseline RTL (i.e. shortest vs. longest) was 2.00 (95% confidence interval: 0.90 to 4.49; P = 0.091), and 2.31 comparing the bottom quartile vs. the remainder (1.21 to 4.41; P = 0.011). The corresponding hazard ratios corrected for within-person RTL variability were 3.22 (1.27 to 8.14; P = 0.014) and 2.86 (1.45 to 5.65; P = 0.003). In a random-effects meta-analysis of three prospective cohort studies involving 6,991 participants and 2,011 incident T2DM events, the pooled relative risk was 1.31 (1.07 to 1.60; P = 0.010; I2 = 69%). Low RTL is independently associated with the risk of incident T2DM. To avoid regression dilution biases in observed associations of RTL with disease risk, future studies should implement methods correcting for within-person variability in RTL. The causal role of short telomeres in T2DM development remains to be determined.

  5. Oximetry and indications for tracheotomy for amyotrophic lateral sclerosis.

    PubMed

    Bach, John Robert; Bianchi, Carlo; Aufiero, Elaine

    2004-11-01

    To explore the use of oximetry as a guide for using respiratory aids and tracheotomy in the treatment of patients with amyotrophic lateral sclerosis (ALS). A retrospective review of all ALS patients presenting to a neuromuscular disease clinic since 1996. Patients who were symptomatic for nocturnal hypoventilation were prescribed noninvasive ventilation (NIV). Patients with assisted cough peak flows of < 300 L/min were prescribed oximeters and access to mechanically assisted coughing (MAC) to prevent or reverse decreases in baseline pulse oximetric saturation (Spo(2)) levels of < 95%. The number of decreases in baseline Spo(2) that could be normalized by any combination of NIV and MAC and the duration of normalization were recorded. When the baseline was not or could not be normalized, the time to acute respiratory failure and tracheotomy or death were recorded. Twenty-five patients became dependent on NIV, including 13 patients who received NIV continuously for a mean (+/- SD) period of 19.7 +/- 16.9 months, without desaturation (group 1). For another 76 patients, the daytime baseline Spo(2) level decreased to < 95% 78 times. For 41 patients, the baseline level was corrected by NIV/MAC (group 2) for a mean duration of 11.1 +/- 8.7 months before desaturation reoccurred for 27 patients. Of the latter patients, 11 underwent tracheotomy, 14 died in < 2 months, and 2 had their condition again corrected by the addition of MAC therapy. For 35 patients, the desaturation was not or could not be normalized (group 3). Thirty-three of these 35 patients required tracheotomy or died within 2 months. The only significant difference between groups 1 and 2 and group 3 was significantly poorer glottic function in the patients in group 3. Tracheotomy or death is highly likely within 2 months of a decrease in baseline Spo(2) that cannot be corrected by NIV or MAC. The long-term use of NIV and MAC, and the avoidance of tracheotomy is dependent on glottic function rather than on inspiratory or expiratory muscle failure.

  6. A Guide for Estimation of Aeroacoustic Loads on Flight Vehicle Surfaces

    DTIC Science & Technology

    1977-02-01

    Nozzle aspect ratio correction of one-third octave band sound pressure levels of USB noise . 122 31. Impingement angle correction of one-third octave...breech weapons ....................... 175 IX •: •-•,..i .•,z. •... LIST OF FIGURES (Cont.) page Figure 61. Rectangular cavity ...and a nozzle aspect ratio of 4.0, and without a deflector. Obtain the corrected one-third octave band level SPL from the baseline level, from " b

  7. Testing the predictive value of peripheral gene expression for nonremission following citalopram treatment for major depression.

    PubMed

    Guilloux, Jean-Philippe; Bassi, Sabrina; Ding, Ying; Walsh, Chris; Turecki, Gustavo; Tseng, George; Cyranowski, Jill M; Sibille, Etienne

    2015-02-01

    Major depressive disorder (MDD) in general, and anxious-depression in particular, are characterized by poor rates of remission with first-line treatments, contributing to the chronic illness burden suffered by many patients. Prospective research is needed to identify the biomarkers predicting nonremission prior to treatment initiation. We collected blood samples from a discovery cohort of 34 adult MDD patients with co-occurring anxiety and 33 matched, nondepressed controls at baseline and after 12 weeks (of citalopram plus psychotherapy treatment for the depressed cohort). Samples were processed on gene arrays and group differences in gene expression were investigated. Exploratory analyses suggest that at pretreatment baseline, nonremitting patients differ from controls with gene function and transcription factor analyses potentially related to elevated inflammation and immune activation. In a second phase, we applied an unbiased machine learning prediction model and corrected for model-selection bias. Results show that baseline gene expression predicted nonremission with 79.4% corrected accuracy with a 13-gene model. The same gene-only model predicted nonremission after 8 weeks of citalopram treatment with 76% corrected accuracy in an independent validation cohort of 63 MDD patients treated with citalopram at another institution. Together, these results demonstrate the potential, but also the limitations, of baseline peripheral blood-based gene expression to predict nonremission after citalopram treatment. These results not only support their use in future prediction tools but also suggest that increased accuracy may be obtained with the inclusion of additional predictors (eg, genetics and clinical scales).

  8. Vision Outcomes Following Anti-Vascular Endothelial Growth Factor Treatment of Diabetic Macular Edema in Clinical Practice.

    PubMed

    Holekamp, Nancy M; Campbell, Joanna; Almony, Arghavan; Ingraham, Herbert; Marks, Steven; Chandwani, Hitesh; Cole, Ashley L; Kiss, Szilárd

    2018-04-20

    To determine monitoring and treatment patterns, and vision outcomes in real-world patients initiating anti-vascular endothelial growth factor (anti-VEGF) therapy for diabetic macular edema (DME). Retrospective interventional cohort study. SETTING: Electronic medical record analysis of Geisinger Health System data. 110 patients (121 study eyes) initiating intravitreal ranibizumab or bevacizumab for DME during January 2007‒May 2012, with baseline corrected visual acuity of 20/40‒20/320, and ≥1 ophthalmologist visits during follow-up. Intravitreal injections per study eye during the first 12 months; corrected visual acuity, change in corrected visual acuity from baseline, proportions of eyes with ≥10 or ≥15 approxEarly Treatment Diabetic Retinopathy Study letter gain/loss at 12 months; number of ophthalmologist visits. Over 12 months, mean number of ophthalmologist visits was 9.2; mean number of intravitreal injections was 3.1 (range, 1-12), with most eyes (68.6%) receiving ≤3 injections. At 12 months, mean corrected visual acuity change was +4.7 letters (mean 56.9 letters at baseline); proportions of eyes gaining ≥10 or ≥15 letters were 31.4% and 24.0%, respectively; proportions of eyes losing ≥10 or ≥15 letters were 10.8% and 8.3%, respectively. Eyes receiving adjunctive laser during the first 6 months (n = 33) showed similar change in corrected visual acuity to non-laser-treated eyes (n = 88) (+3.1 vs +5.3 letters at 12 months). DME patients receiving anti-VEGF therapy in clinical practice undergo less frequent monitoring and intravitreal injections, and achieve inferior vision outcomes to patients in landmark clinical trials. Copyright © 2018. Published by Elsevier Inc.

  9. Reversible Microvascular Hyporeactivity to Acetylcholine During Diabetic Ketoacidosis.

    PubMed

    Joffre, Jérémie; Bourcier, Simon; Hariri, Geoffroy; Miailhe, Arnaud-Felix; Bigé, Naike; Dumas, Guillaume; Dubée, Vincent; Boelle, Pierre-Yves; Abdallah, Idriss; Baudel, Jean-Luc; Guidet, Bertrand; Maury, Eric; Ait-Oufella, Hafid

    2018-05-18

    Metabolic acidosis is commonly observed in critically ill patients. Experimental studies suggested that acidosis by itself could impair vascular function, but this has been poorly investigated in human. Prospective observational study. Medical ICU in a tertiary teaching hospital. To assess the relationship between metabolic acidosis severity and microvascular reactivity, we included adult diabetic patients admitted in ICU for ketoacidosis. Microvascular response to acetylcholine iontophoresis was measured at admission (baseline) and after correction of metabolic acidosis (24 hr). None. Thirty-nine patients with diabetic ketoacidosis were included (68% male), with a median age of 43 (31-57) years. At admission, microvascular reactivity negatively correlated with acidosis severity (R = -0.53; p < 0.001). Microvascular response was strongly depressed at pH less than 7.20 (area under the curve, 1,779 [740-3,079] vs 12,944 [4,874-21,596] at pH > 7.20; p < 0.0001). In addition, acidosis severity was significantly correlated with capillary refill time (R = 0.50; p = 0.02). At H24, after rehydration and insulin infusion, clinical and biological disorders were fully corrected. After acidosis correction, microvascular reactivity increased more in patients with severe baseline acidosis (pH < 7.20) than in those with mild baseline acidosis (area under the curve, +453% [213%-1,470%] vs +121% [79%-312%]; p < 0.01). We identified an alteration of microvascular reactivity during metabolic acidosis in critically ill patients with diabetic ketoacidosis. Microvascular hyporeactivity recovered after acidosis correction.

  10. Linagliptin improved glycaemic control without weight gain or hypoglycaemia in patients with Type 2 diabetes inadequately controlled by a combination of metformin and pioglitazone: a 24-week randomized, double-blind study

    PubMed Central

    Bajaj, M; Gilman, R; Patel, S; Kempthorne-Rawson, J; Lewis-D'Agostino, D; Woerle, H-J

    2014-01-01

    Aims To investigate the efficacy and safety of the dipeptidyl peptidase-4 inhibitor linagliptin in patients with Type 2 diabetes mellitus inadequately controlled by a combination of metformin and pioglitazone. Methods This was a multi-centre, phase 3, randomized, double-blind, placebo-controlled study comparing linagliptin 5 mg once daily (n = 183) and placebo (n = 89) as add-on to metformin and pioglitazone. The primary endpoint was the change from baseline in glycated haemoglobin (HbA1c) after 24 weeks. Results The placebo-corrected adjusted mean (se) change in HbA1c from baseline to 24 weeks was –6 (1) mmol/mol [–0.57 (0.13)%] (P < 0.0001). In patients with baseline HbA1c ≥ 53 mmol/mol (7.0%), 32.4% of patients in the linagliptin group and 13.8% in the placebo group achieved HbA1c < 53 mmol/mol (7.0%) (odds ratio 2.94; P = 0.0033). The placebo-corrected adjusted mean (se) change from baseline in fasting plasma glucose at week 24 was –0.57 (0.26) mmol/l [–10.4 (4.7) mg/dl] (P = 0.0280). The incidence of serious adverse events was 2.2% with linagliptin and 3.4% with placebo. Investigator-defined hypoglycaemia occurred in 5.5% of the linagliptin group and 5.6% of the placebo group. No meaningful changes in mean body weight were noted for either group. Conclusions Linagliptin as add-on therapy to metformin and pioglitazone produced significant and clinically meaningful improvements in glycaemic control, without an additional risk of hypoglycaemia or weight gain (Clinical Trials Registry No: NCT 00996658). PMID:24824197

  11. Assessment of estimated retinal atrophy progression in Stargardt macular dystrophy using spectral-domain optical coherence tomography

    PubMed Central

    Strauss, Rupert W; Muñoz, Beatriz; Wolfson, Yulia; Sophie, Raafay; Fletcher, Emily; Bittencourt, Millena G; Scholl, Hendrik P N

    2016-01-01

    Aims To estimate disease progression based on analysis of macular volume measured by spectral-domain optical coherence tomography (SD-OCT) in patients affected by Stargardt macular dystrophy (STGD1) and to evaluate the influence of software errors on these measurements. Methods 58 eyes of 29 STGD1 patients were included. Numbers and types of algorithm errors were recorded and manually corrected. In a subgroup of 36 eyes of 18 patients with at least two examinations over time, total macular volume (TMV) and volumes of all nine Early Treatment of Diabetic Retinopathy Study (ETDRS) subfields were obtained. Random effects models were used to estimate the rate of change per year for the population, and empirical Bayes slopes were used to estimate yearly decline in TMV for individual eyes. Results 6958 single B-scans from 190 macular cube scans were analysed. 2360 (33.9%) showed algorithm errors. Mean observation period for follow-up data was 15 months (range 3–40). The median (IQR) change in TMV using the empirical Bayes estimates for the individual eyes was −0.103 (−0.145, −0.059) mm3 per year. The mean (±SD) TMV was 6.321±1.000 mm3 at baseline, and rate of decline was −0.118 mm3 per year (p=0.003). Yearly mean volume change was −0.004 mm3 in the central subfield (mean baseline=0.128 mm3), −0.032 mm3 in the inner (mean baseline=1.484 mm3) and −0.079 mm3 in the outer ETDRS subfields (mean baseline=5.206 mm3). Conclusions SD-OCT measurements allow monitoring the decline in retinal volume in STGD1; however, they require significant manual correction of software errors. PMID:26568636

  12. Electrocardiogram signal denoising based on empirical mode decomposition technique: an overview

    NASA Astrophysics Data System (ADS)

    Han, G.; Lin, B.; Xu, Z.

    2017-03-01

    Electrocardiogram (ECG) signal is nonlinear and non-stationary weak signal which reflects whether the heart is functioning normally or abnormally. ECG signal is susceptible to various kinds of noises such as high/low frequency noises, powerline interference and baseline wander. Hence, the removal of noises from ECG signal becomes a vital link in the ECG signal processing and plays a significant role in the detection and diagnosis of heart diseases. The review will describe the recent developments of ECG signal denoising based on Empirical Mode Decomposition (EMD) technique including high frequency noise removal, powerline interference separation, baseline wander correction, the combining of EMD and Other Methods, EEMD technique. EMD technique is a quite potential and prospective but not perfect method in the application of processing nonlinear and non-stationary signal like ECG signal. The EMD combined with other algorithms is a good solution to improve the performance of noise cancellation. The pros and cons of EMD technique in ECG signal denoising are discussed in detail. Finally, the future work and challenges in ECG signal denoising based on EMD technique are clarified.

  13. Stability analysis of geomagnetic baseline data obtained at Cheongyang observatory in Korea

    NASA Astrophysics Data System (ADS)

    Amran, Shakirah M.; Kim, Wan-Seop; Cho, Heh Ree; Park, Po Gyu

    2017-07-01

    The stability of baselines produced by Cheongyang (CYG) observatory from the period of 2014 to 2016 is analysed. Step heights of higher than 5 nT were found in H and Z components in 2014 and 2015 due to magnetic noise in the absolute-measurement hut. In addition, a periodic modulation behaviour observed in the H and Z baseline curves was related to annual temperature variation of about 20 °C in the fluxgate magnetometer hut. Improvement in data quality was evidenced by a small dispersion between successive measurements from June 2015 to the end of 2016. Moreover, the baseline was also improved by correcting the discontinuity in the H and Z baselines.

  14. An online spaced-education game to teach and assess medical students: a multi-institutional prospective trial.

    PubMed

    Kerfoot, B Price; Baker, Harley; Pangaro, Louis; Agarwal, Kathryn; Taffet, George; Mechaber, Alex J; Armstrong, Elizabeth G

    2012-10-01

    To investigate whether a spaced-education (SE) game can be an effective means of teaching core content to medical students and a reliable and valid method of assessing their knowledge. This nine-month trial (2008-2009) enrolled students from three U.S. medical schools. The SE game consisted of 100 validated multiple-choice questions-explanations in preclinical/clinical domains. Students were e-mailed two questions daily. Adaptive game mechanics re-sent questions in three or six weeks if answered, respectively, incorrectly or correctly. Questions expired if not answered on time (appointment dynamic). Students retired questions by answering each correctly twice consecutively (progression dynamic). Posting of relative performance fostered competition. Main outcome measures were baseline and completion scores. Seven-hundred thirty-one students enrolled. Median baseline score was 53% (interquartile range [IQR] 16) and varied significantly by year (P<.001, dmax=2.08), school (P<.001, dmax=0.75), and gender (P<.001, d=0.38). Median completion score was 93% (IQR 12) and varied significantly by year (P=.001, dmax=1.12), school (P<.001, dmax=0.34), and age (P=.019, dmax=0.43). Scores did not differ significantly between years 3 and 4. Seventy percent of enrollees (513/731) requested to participate in future SE games. An SE game is an effective and well-accepted means of teaching core content and a reliable and valid method to assess student knowledge. SE games may be valuable tools to identify and remediate students who could benefit from additional educational support.

  15. Improving Graduate Students' Graphing Skills of Multiple Baseline Designs with Microsoft[R] Excel 2007

    ERIC Educational Resources Information Center

    Lo, Ya-yu; Starling, A. Leyf Peirce

    2009-01-01

    This study examined the effects of a graphing task analysis using the Microsoft[R] Office Excel 2007 program on the single-subject multiple baseline graphing skills of three university graduate students. Using a multiple probe across participants design, the study demonstrated a functional relationship between the number of correct graphing…

  16. Teaching Children with Autism to Discriminate the Reinforced and Nonreinforced Responses of Others: Implications for Observational Learning

    ERIC Educational Resources Information Center

    DeQuinzio, Jaime Ann; Taylor, Bridget A.

    2015-01-01

    We taught 4 participants with autism to discriminate between the reinforced and nonreinforced responses of an adult model and evaluated the effectiveness of this intervention using a multiple baseline design. During baseline, participants were simply exposed to adult models' correct and incorrect responses and the respective consequences of each.…

  17. Evaluation of 5 Hour Energy Drink on the Blood Pressure and Electrocardiograph Parameters on Young Healthy Volunteers: A Randomized, Double Blind, Crossover, Placebo-Controlled Trial (Presentation)

    DTIC Science & Technology

    2014-02-11

    other substances. • There have been reports of atrial fibrillation , Takotsubo cardiomyopathy and sudden cardiac deaths in healthy individuals...baseline cardiac rhythm, history of atrial or ventricular arrhythmia, baseline corrected QT (QTc) interval greater than 440 milliseconds (msec

  18. Evaluating the utility of two gestural discomfort evaluation methods

    PubMed Central

    Son, Minseok; Jung, Jaemoon; Park, Woojin

    2017-01-01

    Evaluating physical discomfort of designed gestures is important for creating safe and usable gesture-based interaction systems; yet, gestural discomfort evaluation has not been extensively studied in HCI, and few evaluation methods seem currently available whose utility has been experimentally confirmed. To address this, this study empirically demonstrated the utility of the subjective rating method after a small number of gesture repetitions (a maximum of four repetitions) in evaluating designed gestures in terms of physical discomfort resulting from prolonged, repetitive gesture use. The subjective rating method has been widely used in previous gesture studies but without empirical evidence on its utility. This study also proposed a gesture discomfort evaluation method based on an existing ergonomics posture evaluation tool (Rapid Upper Limb Assessment) and demonstrated its utility in evaluating designed gestures in terms of physical discomfort resulting from prolonged, repetitive gesture use. Rapid Upper Limb Assessment is an ergonomics postural analysis tool that quantifies the work-related musculoskeletal disorders risks for manual tasks, and has been hypothesized to be capable of correctly determining discomfort resulting from prolonged, repetitive gesture use. The two methods were evaluated through comparisons against a baseline method involving discomfort rating after actual prolonged, repetitive gesture use. Correlation analyses indicated that both methods were in good agreement with the baseline. The methods proposed in this study seem useful for predicting discomfort resulting from prolonged, repetitive gesture use, and are expected to help interaction designers create safe and usable gesture-based interaction systems. PMID:28423016

  19. INVESTIGATING THE EFFECTIVENESS OF KINESIO® TAPING SPACE CORRECTION METHOD IN HEALTHY ADULTS ON PATELLOFEMORAL JOINT AND SUBCUTANEOUS SPACE.

    PubMed

    Lyman, Katie J; Keister, Kassiann; Gange, Kara; Mellinger, Christopher D; Hanson, Thomas A

    2017-04-01

    Limited quantitative, physiological evidence exists regarding the effectiveness of Kinesio® Taping methods, particularly with respect to the potential ability to impact underlying physiological joint space and structures. To better understand the impact of these techniques, the underlying physiological processes must be investigated in addition to the examination of more subjective measures related to pain in unhealthy tissues. The purpose of this study was to determine whether the Kinesio® Taping Space Correction Method created a significant difference in patellofemoral joint space, as quantified by diagnostic ultrasound. Pre-test/post-test prospective cohort study. Thirty-two participants with bilaterally healthy knees and no past history of surgery took part in the study. For each participant, diagnostic ultrasound was utilized to collect three measurements: the patellofemoral joint space, the distance from the skin to the superficial patella, and distance from the skin to the patellar tendon. The Kinesio® Taping Space Correction Method was then applied. After a ten-minute waiting period in a non-weight bearing position, all three measurements were repeated. Each participant served as his or her own control. Paired t tests showed a statistically significant difference (mean difference = 1.1 mm, t [3,1]  = 2.823, p  = 0.008, g  = .465) between baseline and taped conditions in the space between the posterior surface of the patella to the medial femoral condyle. Neither the distance from the skin to the superficial patella nor the distance from the skin to the patellar tendon increased to a statistically significant degree. The application of the Kinesio® Taping Space Correction Method increases the patellofemoral joint space in healthy adults by increasing the distance between the patella and the medial femoral condyle, though it does not increase the distance from the skin to the superficial patella nor to the patellar tendon. 3.

  20. CLASSICAL AREAS OF PHENOMENOLOGY: Correcting dynamic residual aberrations of conformal optical systems using AO technology

    NASA Astrophysics Data System (ADS)

    Li, Yan; Li, Lin; Huang, Yi-Fan; Du, Bao-Lin

    2009-07-01

    This paper analyses the dynamic residual aberrations of a conformal optical system and introduces adaptive optics (AO) correction technology to this system. The image sharpening AO system is chosen as the correction scheme. Communication between MATLAB and Code V is established via ActiveX technique in computer simulation. The SPGD algorithm is operated at seven zoom positions to calculate the optimized surface shape of the deformable mirror. After comparison of performance of the corrected system with the baseline system, AO technology is proved to be a good way of correcting the dynamic residual aberration in conformal optical design.

  1. Detecting benzoyl peroxide in wheat flour by line-scan macro-scale Raman chemical imaging

    NASA Astrophysics Data System (ADS)

    Qin, Jianwei; Kim, Moon S.; Chao, Kuanglin; Gonzalez, Maria; Cho, Byoung-Kwan

    2017-05-01

    Excessive use of benzoyl peroxide (BPO, a bleaching agent) in wheat flour can destroy flour nutrients and cause diseases to consumers. A macro-scale Raman chemical imaging method was developed for direct detection of BPO mixed in the wheat flour. A 785 nm line laser was used in a line-scan Hyperspectral Raman imaging system. Raman images were collected from wheat flour mixed with BPO at eight concentrations (w/w) from 50 to 6,400 ppm. A sample holder (150×100×2 mm3) was used to present a thin layer (2 mm thick) of the powdered sample for image acquisition. A baseline correction method was used to correct the fluctuating fluorescence signals from the wheat flour. To isolate BPO particles from the flour background, a simple thresholding method was applied to the single-band fluorescence-free images at a unique Raman peak wavenumber (i.e., 1001 cm-1) preselected for the BPO detection. Chemical images were created to detect and map the BPO particles. Limit of detection for the BPO was estimated in the order of 50 ppm, which is on the same level with regulatory standards.

  2. Tau-U: A Quantitative Approach for Analysis of Single-Case Experimental Data in Aphasia.

    PubMed

    Lee, Jaime B; Cherney, Leora R

    2018-03-01

    Tau-U is a quantitative approach for analyzing single-case experimental design (SCED) data. It combines nonoverlap between phases with intervention phase trend and can correct for a baseline trend (Parker, Vannest, & Davis, 2011). We demonstrate the utility of Tau-U by comparing it with the standardized mean difference approach (Busk & Serlin, 1992) that is widely reported within the aphasia SCED literature. Repeated writing measures from 3 participants with chronic aphasia who received computer-based writing treatment are analyzed visually and quantitatively using both Tau-U and the standardized mean difference approach. Visual analysis alone was insufficient for determining an effect between the intervention and writing improvement. The standardized mean difference yielded effect sizes ranging from 4.18 to 26.72 for trained items and 1.25 to 3.20 for untrained items. Tau-U yielded significant (p < .05) effect sizes for 2 of 3 participants for trained probes and 1 of 3 participants for untrained probes. A baseline trend correction was applied to data from 2 of 3 participants. Tau-U has the unique advantage of allowing for the correction of an undesirable baseline trend. Although further study is needed, Tau-U shows promise as a quantitative approach to augment visual analysis of SCED data in aphasia.

  3. Logistic regression function for detection of suspicious performance during baseline evaluations using concussion vital signs.

    PubMed

    Hill, Benjamin David; Womble, Melissa N; Rohling, Martin L

    2015-01-01

    This study utilized logistic regression to determine whether performance patterns on Concussion Vital Signs (CVS) could differentiate known groups with either genuine or feigned performance. For the embedded measure development group (n = 174), clinical patients and undergraduate students categorized as feigning obtained significantly lower scores on the overall test battery mean for the CVS, Shipley-2 composite score, and California Verbal Learning Test-Second Edition subtests than did genuinely performing individuals. The final full model of 3 predictor variables (Verbal Memory immediate hits, Verbal Memory immediate correct passes, and Stroop Test complex reaction time correct) was significant and correctly classified individuals in their known group 83% of the time (sensitivity = .65; specificity = .97) in a mixed sample of young-adult clinical cases and simulators. The CVS logistic regression function was applied to a separate undergraduate college group (n = 378) that was asked to perform genuinely and identified 5% as having possibly feigned performance indicating a low false-positive rate. The failure rate was 11% and 16% at baseline cognitive testing in samples of high school and college athletes, respectively. These findings have particular relevance given the increasing use of computerized test batteries for baseline cognitive testing and return-to-play decisions after concussion.

  4. Associations of Adolescent Emotional and Loss of Control Eating with 1-year Changes in Disordered Eating, Weight and Adiposity

    PubMed Central

    Stojek, Monika M. K.; Tanofsky-Kraff, Marian; Shomaker, Lauren B.; Kelly, Nichole R.; Thompson, Katherine A.; Mehari, Rim D.; Marwitz, Shannon E.; Demidowich, Andrew P.; Galescu, Ovidiu A.; Brady, Sheila M.; Yanovski, Susan Z.; Yanovski, Jack A.

    2016-01-01

    Objective Adolescent emotional-eating, referring to eating in response to negative affective states, is frequently reported by those with loss of control (LOC) eating. Although LOC eating has been shown to predict exacerbated disordered eating and excess weight/adiposity gain, the extent to which emotional-eating, either alone or in combination with LOC, predicts adverse outcomes has not been determined. Thus, we examined associations of baseline emotional-eating with changes in disordered eating, BMI, and adiposity over 1-year, and to what degree the presence or absence of baseline LOC moderated these associations. Methods 189 non-treatment-seeking youth (15.4±1.4y; 66% female; 67% non-Hispanic White, 38% overweight [BMI ≥85th %ile]) completed the emotional-eating Scale for Children/Adolescents and the Eating Disorder Examination interview at baseline and again at 1-year. Air displacement plethysmography assessed adiposity at both time points. Results Baseline emotional-eating alone was not significantly associated with the development of objective binge eating or changes in disordered eating attitudes, BMI or adiposity 1-year later. However, baseline emotional-eating interacted with the presence of baseline LOC in the prediction of 1-year outcomes. Among adolescents with LOC eating, greater baseline emotional-eating was related to increased disordered eating attitudes (p=.03), BMI (p=.04), and adiposity (p=.04) at 1-year, after correcting for false discovery rate. Discussion Emotional-eating among youth also reporting LOC was associated with adverse outcomes over 1-year. Adolescents who report both behaviors may represent a subset of individuals at especially high risk for exacerbated disordered eating and excess weight gain. PMID:27753140

  5. Detection and characterization of pulses in broadband seismometers

    USGS Publications Warehouse

    Wilson, David; Ringler, Adam; Hutt, Charles R.

    2017-01-01

    Pulsing - caused either by mechanical or electrical glitches, or by microtilt local to a seismometer - can significantly compromise the long‐period noise performance of broadband seismometers. High‐fidelity long‐period recordings are needed for accurate calculation of quantities such as moment tensors, fault‐slip models, and normal‐mode measurements. Such pulses have long been recognized in accelerometers, and methods have been developed to correct these acceleration steps, but considerable work remains to be done in order to detect and correct similar pulses in broadband seismic data. We present a method for detecting and characterizing the pulses using data from a range of broadband sensor types installed in the Global Seismographic Network. The technique relies on accurate instrument response removal and employs a moving‐window approach looking for acceleration baseline shifts. We find that pulses are present at varying levels in all sensor types studied. Pulse‐detection results compared with average daily station noise values are consistent with predicted noise levels of acceleration steps. This indicates that we can calculate maximum pulse amplitude allowed per time window that would be acceptable without compromising long‐period data analysis.

  6. Comparing Error Correction Procedures for Children Diagnosed with Autism

    ERIC Educational Resources Information Center

    Townley-Cochran, Donna; Leaf, Justin B.; Leaf, Ronald; Taubman, Mitchell; McEachin, John

    2017-01-01

    The purpose of this study was to examine the effectiveness of two error correction (EC) procedures: modeling alone and the use of an error statement plus modeling. Utilizing an alternating treatments design nested into a multiple baseline design across participants, we sought to evaluate and compare the effects of these two EC procedures used to…

  7. Some Direct and Generalized Effects of Replacing an Autistic Man's Echolalia with Correct Responses to Questions.

    ERIC Educational Resources Information Center

    McMorrow, Martin J.; Foxx, R. M.

    1986-01-01

    The use of operant procedures was extended to decrease immediate echolalia and increase appropriate responding to questions of a 21-year-old autistic man. Multiple baseline designs demonstrated that echolalia was rapidly replaced with correct stimulus-specific responses. A variety of generalized improvements were observed in verbal responses to…

  8. A modified method for MRF segmentation and bias correction of MR image with intensity inhomogeneity.

    PubMed

    Xie, Mei; Gao, Jingjing; Zhu, Chongjin; Zhou, Yan

    2015-01-01

    Markov random field (MRF) model is an effective method for brain tissue classification, which has been applied in MR image segmentation for decades. However, it falls short of the expected classification in MR images with intensity inhomogeneity for the bias field is not considered in the formulation. In this paper, we propose an interleaved method joining a modified MRF classification and bias field estimation in an energy minimization framework, whose initial estimation is based on k-means algorithm in view of prior information on MRI. The proposed method has a salient advantage of overcoming the misclassifications from the non-interleaved MRF classification for the MR image with intensity inhomogeneity. In contrast to other baseline methods, experimental results also have demonstrated the effectiveness and advantages of our algorithm via its applications in the real and the synthetic MR images.

  9. Alterations in cyclosporin A pharmacokinetics and metabolism during treatment with St John's wort in renal transplant patients

    PubMed Central

    Bauer, Steffen; Störmer, Elke; Johne, Andreas; Krüger, Hagen; Budde, Klemens; Neumayer, Hans-Hellmut; Roots, Ivar; Mai, Ingrid

    2003-01-01

    Aim This study investigated the effects of St John's wort extract (SJW) on the pharmacokinetics and metabolism of the immunosuppressant cyclosporin A (CSA). Methods In an open-label study, 11 renal transplant patients received 600 mg SJW extract daily for 14 days in addition to their regular regimen of CSA. Blood concentrations of CSA and its metabolites AM1, AM1C, AM9, AM19, and AM4N were measured by HPLC. Results After 2 weeks of SJW coadministration, dose-corrected AUC0–12, Cmax and Ctrough values for CSA decreased significantly by 46%[geometric mean ratio baseline/SJW (95% CI): 1.83 (1.63–2.05)], 42%[1.72 (1.42–2.08)], and 41%[1.70 (1.17–2.47)], respectively. CSA doses were increased from a median of 2.7 mg day−1 kg−1 at baseline to 4.2 mg day−1 kg−1 at day 15, with the first dose adjustment required only 3 days after initiation of SJW treatment. Additionally, the metabolite pattern of CSA was substantially altered during SJW treatment. Whereas dose-corrected AUC values for AM1, AM1c and AM4N significantly decreased by 59%, 61%, and 23% compared with baseline, AUC values for AM9 and AM19 were unchanged. Following the increase in CSA dose, observed AUC and Cmax values for AM9, AM19, and AM4N increased by 20–51% and 43–90%, respectively. Conclusion Administration of SJW extract to patients receiving CSA treatment resulted in a rapid and significant reduction of plasma CSA concentrations. Additionally, the substantial alterations in CSA metabolite kinetics observed may affect the toxicity profile of the drug. PMID:12580993

  10. Enhancement of Functional Connectivity, Working Memory and Inhibitory Control on Multi-modal Brain MR Imaging with Rifaximin in Cirrhosis: Implications for the Gut-Liver-Brain Axis

    PubMed Central

    Ahluwalia, Vishwadeep; Wade, James B; Heuman, Douglas M; Hammeke, Thomas A; Sanyal, Arun J; Sterling, Richard K; Stravitz, R. Todd; Luketic, Velimir; Siddiqui, Mohammad S; Puri, Puneet; Fuchs, Michael; Lennon, Micheal J; Kraft, Kenneth A; Gilles, HoChong; White, Melanie B; Noble, Nicole A; Bajaj, Jasmohan S

    2014-01-01

    Objective Minimal hepatic encephalopathy (MHE) impairs daily functioning in cirrhosis, but its functional brain impact is not completely understood. Aim To evaluate the effect of rifaximin, a gut-specific antibiotic, on the gut-liver-brain axis in MHE. Hypothesis Rifaximin will reduce endotoxemia, enhance cognition, increase activation during working memory(N-back) and reduce activation needed for inhibitory control tasks. Methods Cirrhotics with MHE underwent baseline endotoxin and cognitive testing, then underwent fMRI, diffusion tensor imaging and MR spectroscopy(MRS). On fMRI, two tasks; N-back (outcome: correct responses) and inhibitory control tests(outcomes: lure inhibition) were performed. All procedures were repeated after 8 weeks of rifaximin. Results were compared before/after rifaximin. Results 20 MHE patients (59.7 years) were included; sixteen completed pre/post-rifaximin scanning with 92% medication compliance. Pre-rifaximin patients had cognitive impairment. At trial-end, there was a significantly higher correct 2-back responses, ICT lure inhibitions and reduced endotoxemia(p=0.002). This was accompanied by significantly higher activation from baseline in subcortical structures (thalamus, caudate, insula and hippocampus) and left parietal operculum (LPO) during N-back, decrease in fronto-parietal activation required for inhibiting lures, including LPO during ICT compared to baseline values. Connectivity studies in N-back showed significant shifts in linkages after therapy in fronto-parietal regions with a reduction in fractional anisotropy (FA) but not mean diffusivity (MD), and no change in MRS metabolites at the end of the trial. Conclusion A significant improvement in cognition including working memory and inhibitory control, and fractional anisotropy without effect on MD or MRS, through modulation of fronto-parietal and subcortical activation and connectivity was seen after open-label rifaximin therapy in MHE. PMID:24590688

  11. The effect of education on decreasing the prevalence and severity of neck and shoulder pain: a longitudinal study in Korean male adolescents

    PubMed Central

    Koh, Min Jung; Park, Eun Jung; Park, Sang Hoon; Jeon, Hea Rim; Kim, Mun-Gyu; Lee, Se-Jin; Kim, Sang Ho; Ok, Si Young; Kim, Soon Im

    2014-01-01

    Background Neck and shoulder pain is fairly common among adolescents in Korea and results in significant health problem. The aims of this prospective study was to identify the effects of education, in terms of recognition of this issue and posture correction, on prevalence and severity of neck and shoulder pain in Korean adolescents. Methods A prospective, observational cohort design was used. The 912 students from two academic high schools in the city of Seoul were eligible for the current study and 887 completed this study. After a baseline cross-sectional survey, students listened to a lecture about cervical health, focusing on good posture, habits, and stretching exercises to protect the spine, and were encouraged by their teachers to keep the appropriate position. And follow-ups were conducted 3 months later, to evaluate the effect of education. Results The prevalence of neck and shoulder pain was decreased 19.5% (from 82.5 to 66.4%). The baseline mean usual and worst numeric rating scale were 19.9/100 (95% CI, 18.1-21.7) and 31.2/100 (95% CI, 28.7-33.2), respectively. On the follow-up survey, the mean usual and worst numeric rating scale were decreased significantly by 24.1 and 21.7%, respectively, compared with baseline (P < 0.01). Of the 570 students reporting neck and shoulder pain, 16.4% responded that they had experienced improvement during the 3 months. Conclusions Education; recognition of this issue and posture correction, for cervical health appeared to be effective in decreasing the prevalence and severity of neck and shoulder pain at a 3 month follow-up. PMID:25301193

  12. Differences in Postprandial Lipid Response to Breast- or Formula-feeding in 8-Week-Old Infants.

    PubMed

    Teller, Inga C; Schoen, Stefanie; van de Heijning, Bert; van der Beek, Eline M; Sauer, Pieter J J

    2017-04-01

    Lipids play important roles in infant growth and development. In this exploratory observational single-center study, we investigated postmeal responses of infants to dietary lipids and differences between breast-feeding (BF) and formula-feeding (FF). Two capillary blood samples were collected from each subject, before and randomly assigned at either 30, 60, 90, 120, 180, or 240 minutes after their respective feeding, followed by measurement of lipid-related plasma parameter concentrations using enzyme-linked immunosorbent assay-based or combined enzymatic and colorimetric methods. The intermeal interval before testing was shorter in the BF (182.91 ± 22.85 minutes, n = 33) versus FF group (214.1 ± 30.76 minutes, n = 34); BF subjects fed 5 minutes longer (BF 20.27 ± 7.7 minutes; FF 14.82 ± 3.57 minutes). Composite postmeal concentration profiles were generated from 59 plasma sample pairs with sufficient volume (BF = 30): triglyceride (TG) baselines were not different. A TG difference was indicated for BF over FF subjects at 30 minutes, for FF over BF subjects at 60 minutes when corrected for baseline. TG responses in both groups appeared and seemed to clear much faster than those reported for adults. The TG:apolipoprotein B48 (ApoB48) ratio suggests that chylomicrons in BF subjects may carry a higher fat load (P < 0.05), compensated by a higher chylomicron number in FF subjects (P < 0.05). Cholesterol in BF subjects was higher and showed an increase after feeding when corrected for baseline. Our results indicate that lipids from either BF or FF may be handled differently in young healthy infants.

  13. Effects of PECS Phase III Application Training on Independent Mands in Young Children with Autism

    ERIC Educational Resources Information Center

    Love, Jessica June

    2013-01-01

    The purpose of this study was to examine the effects of PECS phase III application training on independent mands in young children with autism. Participants were five children with autism ranging from ages 2 to 4 years old. A multiple baseline across participants was used to evaluate acquisition of independent correct mands across baseline and…

  14. CLINICAL AND ELECTROPHYSIOLOGICAL EVALUATION AFTER INTRAVITREAL ZIV-AFLIBERCEPT FOR EXUDATIVE AGE-RELATED MACULAR DEGENERATION.

    PubMed

    de Oliveira Dias, João Rafael; de Andrade, Gabriel Costa; Kniggendorf, Vinicius Ferreira; Novais, Eduardo Amorim; Maia, André; Meyer, Carsten; Watanabe, Sung Eun Song; Farah, Michel Eid; Rodrigues, Eduardo Büchele

    2017-08-01

    To evaluate the 6-month safety and efficacy of ziv-aflibercept intravitreal injections for treating exudative age-related macular degeneration. Fifteen patients with unilateral exudative age-related macular degeneration were enrolled. The best-corrected visual acuity was measured and spectral domain optical coherence tomography was performed at baseline and monthly. Full-field electroretinography and multifocal electroretinography were obtained at baseline and 4, 13, and 26 weeks after the first injection. All patients received three monthly intravitreal injections of ziv-aflibercept (1.25 mg) followed by as-needed treatment. Between baseline and 26 weeks, the mean logMAR best-corrected visual acuity improved (P = 0.00408) from 0.93 ± 0.4 (20/200) to 0.82 ± 0.5 (20/160) logarithm of the minimum angle of resolution, respectively; the central retinal thickness decreased significantly (P = 0.0007) from 490.3 ± 155.1 microns to 327.9 ± 101.5 microns; the mean total macular volume decreased significantly (P < 0.0001) from 9.51 ± 1.36 mm to 8.08 ± 1.34 mm, and the a-wave implicit time increased, with no differences in the other full-field electroretinography parameters. The average multifocal electroretinography macular responses within the first central 15° showed significantly (P < 0.05) increased P1 amplitudes at 26 weeks. No systemic or ocular complications developed. Intravitreal ziv-aflibercept significantly improved the best-corrected visual acuity, multifocal electroretinography amplitudes, central retinal thickness, and total macular volume from baseline to 26 weeks. No retinal toxicity on full-field electroretinography or adverse events occurred during the follow-up period.

  15. Effect of an intervention on quality indicators for improving the treatment of hyperglycemia in patients hospitalized in noncritical areas.

    PubMed

    Ena, J; Gómez-Huelgas, R; Zapatero-Gaviria, A; Vázquez-Rodriguez, P; González-Becerra, C; Romero-Sánchez, M; Igúzquiza-Pellejero, M J; Artero-Mora, A; Varela-Aguilar, J M

    2016-10-01

    We evaluated the effect of an intervention on certain quality indicators employed for improving the treatment of hospital hyperglycemia. A multicenter cross-sectional study was conducted on patients with hyperglycemia hospitalized in the internal medicine departments of 44 hospitals evaluated in 2 time periods: 2014 (baseline period) and 2015 (postintervention period). The intervention consisted of the dissemination of the indicators obtained in 2014 and the objectives for improvement. As indicators, we assessed the frequency of glucose monitoring adapted to the patient's dietary intake or medication, the use of basal-bolus or basal-bolus-correction insulin therapy as the preferred control method of hyperglycemia and the recent availability of HbA1c prior to hospital discharge. A total of 506 and 562 patients were assessed in 2014 and 2015, respectively. The results of the indicators in the baseline and postintervention periods were as follows: blood glucose monitoring adapted to the dietary intake or the medication (71.5 vs. 74.1%, P=.33), use of insulin in basal-correction regimen (32 vs. 32.6%, P=.61) or basal-bolo-correction (20.7 vs. 24, P=.20) and recent HbA1c value (54.1 vs. 66.3%, P<.001). The mean glucose values in the 24h prior to the study were similar in the 2 periods. The rate of hypoglycemia was also similar in both periods (3.3 vs. 2.3%, P=.31). There is a need to implement multimodal interventions to improve the treatment of hyperglycemia in patients hospitalized in noncritical areas. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Medicina Interna (SEMI). All rights reserved.

  16. Altered cerebral perfusion in executive, affective, and motor networks during adolescent depression.

    PubMed

    Ho, Tiffany C; Wu, Jing; Shin, David D; Liu, Thomas T; Tapert, Susan F; Yang, Guang; Connolly, Colm G; Frank, Guido K W; Max, Jeffrey E; Wolkowitz, Owen; Eisendrath, Stuart; Hoeft, Fumiko; Banerjee, Dipavo; Hood, Korey; Hendren, Robert L; Paulus, Martin P; Simmons, Alan N; Yang, Tony T

    2013-10-01

    Although substantial literature has reported regional cerebral blood flow (rCBF) abnormalities in adults with depression, these studies commonly necessitated the injection of radioisotopes into subjects. The recent development of arterial spin labeling (ASL), however, allows noninvasive measurements of rCBF. Currently, no published ASL studies have examined cerebral perfusion in adolescents with depression. Thus, the aim of the present study was to examine baseline cerebral perfusion in adolescent depression using a newly developed ASL technique: pseudocontinuous arterial spin labeling (PCASL). A total of 25 medication-naive adolescents (13-17 years of age) diagnosed with major depressive disorder (MDD) and 26 well-matched control subjects underwent functional magnetic resonance imaging. Baseline rCBF was measured via a novel PCASL method that optimizes tagging efficiency. Voxel-based whole brain analyses revealed significant frontal, limbic, paralimbic, and cingulate hypoperfusion in the group with depression (p < .05, corrected). Hyperperfusion was also observed within the subcallosal cingulate, putamen, and fusiform gyrus (p < .05, corrected). Similarly, region-of-interest analyses revealed amygdalar and insular hypoperfusion in the group with depression, as well as hyperperfusion in the putamen and superior insula (p < .05, corrected). Adolescents with depression and healthy adolescents appear to differ on rCBF in executive, affective, and motor networks. Dysfunction in these regions may contribute to the cognitive, emotional, and psychomotor symptoms commonly present in adolescent depression. These findings point to possible biomarkers for adolescent depression that could inform early interventions and treatments, and establishes a methodology for using PCASL to noninvasively measure rCBF in clinical and healthy adolescent populations. Copyright © 2013 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  17. Impacts of Satellite Orbit and Clock on Real-Time GPS Point and Relative Positioning.

    PubMed

    Shi, Junbo; Wang, Gaojing; Han, Xianquan; Guo, Jiming

    2017-06-12

    Satellite orbit and clock corrections are always treated as known quantities in GPS positioning models. Therefore, any error in the satellite orbit and clock products will probably cause significant consequences for GPS positioning, especially for real-time applications. Currently three types of satellite products have been made available for real-time positioning, including the broadcast ephemeris, the International GNSS Service (IGS) predicted ultra-rapid product, and the real-time product. In this study, these three predicted/real-time satellite orbit and clock products are first evaluated with respect to the post-mission IGS final product, which demonstrates cm to m level orbit accuracies and sub-ns to ns level clock accuracies. Impacts of real-time satellite orbit and clock products on GPS point and relative positioning are then investigated using the P3 and GAMIT software packages, respectively. Numerical results show that the real-time satellite clock corrections affect the point positioning more significantly than the orbit corrections. On the contrary, only the real-time orbit corrections impact the relative positioning. Compared with the positioning solution using the IGS final product with the nominal orbit accuracy of ~2.5 cm, the real-time broadcast ephemeris with ~2 m orbit accuracy provided <2 cm relative positioning error for baselines no longer than 216 km. As for the baselines ranging from 574 to 2982 km, the cm-dm level positioning error was identified for the relative positioning solution using the broadcast ephemeris. The real-time product could result in <5 mm relative positioning accuracy for baselines within 2982 km, slightly better than the predicted ultra-rapid product.

  18. Time to first treatment: The significance of early treatment of exudative age-related macular degeneration.

    PubMed

    Rauch, Renate; Weingessel, Birgit; Maca, Saskia M; Vecsei-Marlovits, Pia V

    2012-07-01

    To determine whether the time span between initial symptoms and treatment with ranibizumab in patients with neovascular age-related macular degeneration has an effect on visual outcome. In this retrospective study, 45 patients with exudative age-related macular degeneration were split into 3 groups depending on the duration of visual symptoms--Group I: <1 month, Group II: 1 month to 6 months, and Group III: >6 months. Best-corrected visual acuity, clinical ophthalmologic examination, and central retinal thickness as measured by optical coherence tomography were recorded at baseline and 2 months later. Fluorescein angiography was performed at baseline. Treatment consisted of 2 intravitreal injections of 1.25 mg of ranibizumab at baseline and after 4 weeks. The mean time span between initial symptoms and treatment was 59 ± 62 days. In all groups, a reduction of retinal thickness was observed. Shorter disease duration, as estimated by persistence of visual symptoms, was correlated with a better visual outcome after treatment. Patients in Group I demonstrated a significant increase in best-corrected visual acuity (P = 0.007). Patients of Group II (P = 0.095) and Group III (P = 0.271) still achieved a visual improvement in best-corrected visual acuity, albeit not significant. The mean change in best-corrected visual acuity was 0.08 ± 0.1 in all patients and was not statistically significant between groups (P = 0.87). Duration of visual symptoms <1 month before treatment is associated with a better visual outcome. Treatment of new-onset wet age-related macular degeneration should be initiated as soon as possible.

  19. Metric-wave and decimetric-wave aperture synthesis systems (review)

    NASA Astrophysics Data System (ADS)

    Ilyasov, Y. P.

    1984-09-01

    Aperture synthesis systems using metric or decimetric waves are adequate and promising for astrophysical study of extragalactic radioemission sources, operation with metric waves being characterized by destabilizing effects of the ionosphere and thus requiring special methods of data processing. Methods of closure phase and closure amplitude were proposed and then successfully implemented in very-large-baseline radiotelescope and multi-element interferometers, respectively. Several radiotelescopes were developed which operate in the supersynthesis mode, with rotation of the Earth used for filling the space-frequency plane. Further achievements include the Swarup system (Uti/INDIA) with phase-stable interferometer, the Jodrell Bank system (Manchester/UK), the Palmer Merlin multielement system (UK) with CLEAN procedure and CORTEL telescope correction algorithm, the VLA system (USA), and the international giant equatorial radiotelescope.

  20. Ill Effects of Smoking: Baseline Knowledge among School Children and Implementation of the “AntE Tobacco” Project

    PubMed Central

    Surani, Salim; Reddy, Raghu; Houlihan, Amy E.; Parrish, Brenda; Evans-Hudnall, Gina L.; Guntupalli, Kalpalatha

    2011-01-01

    Introduction. Cigarette smoking contributes to the deaths of more than 400,000 Americans annually. Each day >3,000 children and adolescents become regular smokers. This paper details a new antitobacco educational program titled “AntE Tobacco” Method. Children in grades 1–3 were administered a 10-item questionnaire to ascertain their baseline knowledge about the ill effects of smoking, shown an educational cartoon video depicting the ill effects of tobacco, and given a story book based on the video. At the end of video, children were administered a questionnaire to determine short-term recall of the antitobacco educational objectives of the program. Four to 6 weeks later, the children were then administered a follow-up survey to determine long-term retention of the anti tobacco educational program. Result. Eighty two percent of the children answered the outcome questions correctly immediately following the video. At follow-up, 4–6 weeks later, 83% of children answered all questions correctly. Conclusion. The anti tobacco education program used in this study effectively conveyed most of the educational objectives. The results of this study indicate that a multimedia (i.e., video and book) educational program can be used to educate and reinforce anti tobacco messages. This program may be very useful as a part of a comprehensive anti tobacco curriculum in school systems. PMID:21716695

  1. Study on the effectiveness of the kinetic method in patients with rheumatic diseases and temporomandibular joint dysfunction.

    PubMed

    Havriş, Maria Daniela; Ancuţa, Codrina; Iordache, Cristina; Chirieac, Rodica Marieta

    2012-01-01

    Selecting the appropriate treatment decision is essential for achieving optimal results in the management of algo-dysfunctional syndrome of the temporo-mandibular joint (TMJD). The study aims to decide on the most effective (symptomatic control, preserved motility) kinetic program in patients with TMJ involvement. prospective observational study on 83 consecutive patients with rheumatic diseases and TMJ dysfunction. Clinical assessment (pain, noises, muscle spasm, range of motion, ROM) was performed at baseline and after 3 months of specific kinetic rehabilitation program. Change in clinical parameters and TM3 index was reported, p<0.05. over 45% TMJ involvement at baseline as defined by TMJ index (mean value of 13.56) and only 36.66% at 3 months (p<0.05). Significant improvement in pain (presence, severity) was demonstrated at 3 moths (p<0.05): 18.05% spontaneous pain, 75.9% provoked pain, with 12.11% respectively 2.41% decreased in nocturnal respectively diurnal pain. Significant decrease (p<0.05) in joint noises at movements: 27.71% when opening and 12.04% when closing the mouth, 8.43 at protrusion and 3.61% at retraction, while 18% at the side movements. Complex accurate kinetic reeducation is mandatory for achieving correct posture (head, neck and trunk), normal mastication, swallowing and respiration, as well as correction of neuromuscular imbalances in patients with TMJD secondary to rheumatic disorders.

  2. Ionospheric Correction of InSAR for Accurate Ice Motion Mapping at High Latitudes

    NASA Astrophysics Data System (ADS)

    Liao, H.; Meyer, F. J.

    2016-12-01

    Monitoring the motion of the large ice sheets is of great importance for determining ice mass balance and its contribution to sea level rise. Recently the first comprehensive ice motion of the Greenland and the Antarctica have been generated with InSAR. However, these studies have indicated that the performance of InSAR-based ice motion mapping is limited by the presence of the ionosphere. This is particularly true at high latitudes and for low-frequency SAR data. Filter-based and empirical methods (e.g., removing polynomials), which have often been used to mitigate ionospheric effects, are often ineffective in these areas due to the typically strong spatial variability of ionospheric phase delay in high latitudes and due to the risk of removing true deformation signals from the observations. In this study, we will first present an outline of our split-spectrum InSAR-based ionospheric correction approach and particularly highlight how our method improves upon published techniques, such as the multiple sub-band approach to boost estimation accuracy as well as advanced error correction and filtering algorithms. We applied our work flow to a large number of ionosphere-affected dataset over the large ice sheets to estimate the benefit of ionospheric correction on ice motion mapping accuracy. Appropriate test sites over Greenland and the Antarctic have been chosen through cooperation with authors (UW, Ian Joughin) of previous ice motion studies. To demonstrate the magnitude of ionospheric noise and to showcase the performance of ionospheric correction, we will show examples of ionospheric-affected InSAR data and our ionosphere corrected result for comparison in visual. We also compared the corrected phase data to known ice velocity fields quantitatively for the analyzed areas from experts in ice velocity mapping. From our studies we found that ionospheric correction significantly reduces biases in ice velocity estimates and boosts accuracy by a factor that depends on a set of system (range bandwidth, temporal and spatial baseline) and processing parameters (e.g., filtering strength and sub-band configuration). A case study in Greenland is attached below.

  3. Platform control for space-based imaging: the TOPSAT mission

    NASA Astrophysics Data System (ADS)

    Dungate, D.; Morgan, C.; Hardacre, S.; Liddle, D.; Cropp, A.; Levett, W.; Price, M.; Steyn, H.

    2004-11-01

    This paper describes the imaging mode ADCS design for the TOPSAT satellite, an Earth observation demonstration mission targeted at military applications. The baselined orbit for TOPSAT is a 600-700km sun synchronous orbit from which images up to 30° off track can be captured. For this baseline, the imaging camera proves a resolution of 2.5m and a nominal image size of 15x15km. The ADCS design solution for the imaging mode uses a moving demand approach to enable a single control algorithm solution for both the preparatory reorientation prior to image capture and the post capture return to nadir pointing. During image capture proper, control is suspended to minimise the disturbances experienced by the satellite from the wheels. Prior to each imaging sequence, the moving demand attitude and rate profiles are calculated such that the correct attitude and rate are achieved at the correct orbital position, enabling the correct target area to be captured.

  4. Targeting Performance Dimensions in Sequence According to the Instructional Hierarchy: Effects on Children's Math Work within a Self-Monitoring Program

    ERIC Educational Resources Information Center

    Lannie, Amanda L.; Martens, Brian K.

    2008-01-01

    Four fifth-grade students were presented with frustration-level math probes while three performance dimensions were measured (i.e., percent intervals on-task, percent correct digits, and digits correct per minute (DCM)). Using a multiple baseline design across participants, students were trained to self-monitor time on-task, accuracy, and…

  5. Prone positioning reduces severe pushing behavior: three case studies.

    PubMed

    Fujino, Yuji; Amimoto, Kazu; Sugimoto, Satoshi; Fukata, Kazuhiro; Inoue, Masahide; Takahashi, Hidetoshi; Makita, Shigeru

    2016-09-01

    [Purpose] Pushing behavior is classically described as a disorder of body orientation in the coronal plane. Most interventions for pushing behavior have focused on correcting the deviation in vertical perception. However, pushing behavior seems to involve erroneous movements associated with excessive motor output by the non-paretic limbs and trunk. The present study aimed to inhibit muscular hyper-activity by placing the non-paretic limbs and trunk in the prone position. [Subjects and Methods] The subjects of the present study were 3 acute stroke patients with severe pushing behavior. The study consisted of the following 3 phases: baseline, intervention, and follow-up. In addition to conventional therapy, patients received relaxation therapy in the prone position for 10 minutes a day over 2 days. The severity of pushing behavior was assessed using the scale for contraversive pushing, and truncal balance was evaluated using the trunk control test. These assessments were performed before and after the baseline phase, and after the intervention and follow-up phases. [Results] At the baseline phase, both scores were poor. Both scores improved after the intervention and follow-up phases, and all the patients could sit independently. [Conclusion] Relaxation therapy in the prone position might ameliorate pushing behavior and impaired truncal balance.

  6. The minimizing of fluorescence background in Raman optical activity and Raman spectra of human blood plasma.

    PubMed

    Tatarkovič, Michal; Synytsya, Alla; Šťovíčková, Lucie; Bunganič, Bohuš; Miškovičová, Michaela; Petruželka, Luboš; Setnička, Vladimír

    2015-02-01

    Raman optical activity (ROA) is inherently sensitive to the secondary structure of biomolecules, which makes it a method of interest for finding new approaches to clinical applications based on blood plasma analysis, for instance the diagnostics of several protein-misfolding diseases. Unfortunately, real blood plasma exhibits strong background fluorescence when excited at 532 nm; hence, measuring the ROA spectra appears to be impossible. Therefore, we established a suitable method using a combination of kinetic quenchers, filtering, photobleaching, and a mathematical correction of residual fluorescence. Our method reduced the background fluorescence approximately by 90%, which allowed speedup for each measurement by an average of 50%. In addition, the signal-to-noise ratio was significantly increased, while the baseline distortion remained low. We assume that our method is suitable for the investigation of human blood plasma by ROA and may lead to the development of a new tool for clinical diagnostics.

  7. Improved Convergence and Robustness of USM3D Solutions on Mixed-Element Grids

    NASA Technical Reports Server (NTRS)

    Pandya, Mohagna J.; Diskin, Boris; Thomas, James L.; Frink, Neal T.

    2016-01-01

    Several improvements to the mixed-element USM3D discretization and defect-correction schemes have been made. A new methodology for nonlinear iterations, called the Hierarchical Adaptive Nonlinear Iteration Method, has been developed and implemented. The Hierarchical Adaptive Nonlinear Iteration Method provides two additional hierarchies around a simple and approximate preconditioner of USM3D. The hierarchies are a matrix-free linear solver for the exact linearization of Reynolds-averaged Navier-Stokes equations and a nonlinear control of the solution update. Two variants of the Hierarchical Adaptive Nonlinear Iteration Method are assessed on four benchmark cases, namely, a zero-pressure-gradient flat plate, a bump-in-channel configuration, the NACA 0012 airfoil, and a NASA Common Research Model configuration. The new methodology provides a convergence acceleration factor of 1.4 to 13 over the preconditioner-alone method representing the baseline solver technology.

  8. Improved Convergence and Robustness of USM3D Solutions on Mixed-Element Grids

    NASA Technical Reports Server (NTRS)

    Pandya, Mohagna J.; Diskin, Boris; Thomas, James L.; Frinks, Neal T.

    2016-01-01

    Several improvements to the mixed-elementUSM3Ddiscretization and defect-correction schemes have been made. A new methodology for nonlinear iterations, called the Hierarchical Adaptive Nonlinear Iteration Method, has been developed and implemented. The Hierarchical Adaptive Nonlinear Iteration Method provides two additional hierarchies around a simple and approximate preconditioner of USM3D. The hierarchies are a matrix-free linear solver for the exact linearization of Reynolds-averaged Navier-Stokes equations and a nonlinear control of the solution update. Two variants of the Hierarchical Adaptive Nonlinear Iteration Method are assessed on four benchmark cases, namely, a zero-pressure-gradient flat plate, a bump-in-channel configuration, the NACA 0012 airfoil, and a NASA Common Research Model configuration. The new methodology provides a convergence acceleration factor of 1.4 to 13 over the preconditioner-alone method representing the baseline solver technology.

  9. Longitudinal Associations among Renal Urea Clearance-Corrected Normalized Protein Catabolic Rate, Serum Albumin, and Mortality in Patients on Hemodialysis.

    PubMed

    Eriguchi, Rieko; Obi, Yoshitsugu; Streja, Elani; Tortorici, Amanda R; Rhee, Connie M; Soohoo, Melissa; Kim, Taehee; Kovesdy, Csaba P; Kalantar-Zadeh, Kamyar

    2017-07-07

    There are inconsistent reports on the association of dietary protein intake with serum albumin and outcomes among patients on hemodialysis. Using a new normalized protein catabolic rate (nPCR) variable accounting for residual renal urea clearance, we hypothesized that higher baseline nPCR and rise in nPCR would be associated with higher serum albumin and better survival among incident hemodialysis patients. Among 36,757 incident hemodialysis patients in a large United States dialysis organization, we examined baseline and change in renal urea clearance-corrected nPCR as a protein intake surrogate and modeled their associations with serum albumin and mortality over 5 years (1/2007-12/2011). Median nPCRs with and without accounting for renal urea clearance at baseline were 0.94 and 0.78 g/kg per day, respectively (median within-patient difference, 0.14 [interquartile range, 0.07-0.23] g/kg per day). During a median follow-up period of 1.4 years, 8481 deaths were observed. Baseline renal urea clearance-corrected nPCR was associated with higher serum albumin and lower mortality in the fully adjusted model ( P trend <0.001). Among 13,895 patients with available data, greater rise in renal urea clearance-corrected nPCR during the first 6 months was also associated with attaining high serum albumin (≥3.8 g/dl) and lower mortality ( P trend <0.001); compared with the reference group (a change of 0.1-0.2 g/kg per day), odds and hazard ratios were 0.53 (95% confidence interval, 0.44 to 0.63) and 1.32 (95% confidence interval, 1.14 to 1.54), respectively, among patients with a change of <-0.2 g/kg per day and 1.62 (95% confidence interval, 1.35 to 1.96) and 0.76 (95% confidence interval, 0.64 to 0.90), respectively, among those with a change of ≥0.5 g/kg per day. Within a given category of nPCR without accounting for renal urea clearance, higher levels of renal urea clearance-corrected nPCR consistently showed lower mortality risk. Among incident hemodialysis patients, higher dietary protein intake represented by nPCR and its changes over time appear to be associated with increased serum albumin levels and greater survival. nPCR may be underestimated when not accounting for renal urea clearance. Compared with the conventional nPCR, renal urea clearance-corrected nPCR may be a better marker of mortality. Copyright © 2017 by the American Society of Nephrology.

  10. Ultrafast mid-infrared spectroscopy by chirped pulse upconversion in 1800-1000cm(-1) region.

    PubMed

    Zhu, Jingyi; Mathes, Tilo; Stahl, Andreas D; Kennis, John T M; Groot, Marie Louise

    2012-05-07

    Broadband femtosecond mid-infrared pulses can be converted into the visible spectral region by chirped pulse upconversion. We report here the upconversion of pump probe transient signals in the frequency region below 1800cm(-1), using the nonlinear optical crystal AgGaGeS4, realizing an important expansion of the application range of this method. Experiments were demonstrated with a slab of GaAs, in which the upconverted signals cover a window of 120cm(-1), with 1.5cm(-1) resolution. In experiments on the BLUF photoreceptor Slr1694, signals below 1 milliOD were well resolved after baseline correction. Possibilities for further optimization of the method are discussed. We conclude that this method is an attractive alternative for the traditional MCT arrays used in most mid-infrared pump probe experiments.

  11. Problems With Risk Reclassification Methods for Evaluating Prediction Models

    PubMed Central

    Pepe, Margaret S.

    2011-01-01

    For comparing the performance of a baseline risk prediction model with one that includes an additional predictor, a risk reclassification analysis strategy has been proposed. The first step is to cross-classify risks calculated according to the 2 models for all study subjects. Summary measures including the percentage of reclassification and the percentage of correct reclassification are calculated, along with 2 reclassification calibration statistics. The author shows that interpretations of the proposed summary measures and P values are problematic. The author's recommendation is to display the reclassification table, because it shows interesting information, but to use alternative methods for summarizing and comparing model performance. The Net Reclassification Index has been suggested as one alternative method. The author argues for reporting components of the Net Reclassification Index because they are more clinically relevant than is the single numerical summary measure. PMID:21555714

  12. Measuring In Vivo Free Radical Production by the Outer Retina

    PubMed Central

    Berkowitz, Bruce A.; Bredell, Bryce X.; Davis, Christopher; Samardzija, Marijana; Grimm, Christian; Roberts, Robin

    2015-01-01

    Purpose Excessive and continuously produced free radicals in the outer retina are implicated in retinal aging and the pathogenesis of sight-threatening retinopathies, yet measuring outer retinal oxidative stress in vivo remains a challenge. Here, we test the hypothesis that continuously produced paramagnetic free radicals from the outer retina can be measured in vivo using high-resolution (22-μm axial resolution) 1/T1magnetic resonance imaging (MRI) without and with a confirmatory quench (quench-assisted MRI). Methods Low-dose sodium iodate–treated and diabetic C57Bl6/J mice (and their controls), and rod-dominated (129S6) or cone-only R91W;Nrl−/− mice were studied. In dark-adapted groups, 1/T1 was mapped transretinally in vivo without or with (1) the antioxidant combination of methylene blue (MB) and α-lipoic acid (LPA), or (2) light exposure; in subgroups, retinal superoxide production was measured ex vivo (lucigenin). Results In the sodium iodate model, retinal superoxide production and outer retina-specific 1/T1 values were both significantly greater than normal and corrected to baseline with MB+LPA therapy. Nondiabetic mice at two ages and 1.2-month diabetic mice (before the appearance of oxidative stress) had similar transretinal 1/T1 profiles. By 2.3 months of diabetes, only outer retinal 1/T1 values were significantly greater than normal and were corrected to baseline with MB+LPA therapy. In mice with healthy photoreceptors, a light quench caused 1/T1 of rods, but not cones, to significantly decrease from their values in the dark. Conclusions Quench-assisted MRI is a feasible method for noninvasively measuring normal and pathologic production of free radicals in photoreceptors/RPE in vivo. PMID:26670830

  13. Anxious Depression and early changes in the HAMD-17 anxiety-somatization factor items and antidepressant treatment outcome

    PubMed Central

    Farabaugh, Amy H.; Bitran, Stella; Witte, Janet; Alpert, Jonathan; Chuzi, Sarah; Clain, Alisabet J.; Baer, Lee; Fava, Maurizio; McGrath, Patrick J.; Dording, Christina; Mischoulon, David; Papakostas, George I

    2010-01-01

    Objective To assess the relationship between early changes in anxiety/somatization symptoms and treatment outcome among MDD subjects during a 12-week trial of fluoxetine. We also examined the relationship between anxious depression and treatment response. Methods 510 MDD patients received 12 weeks of fluoxetine with flexible dosing (target dosages: 10 mg/day (week 1), 20 mg/day (weeks 2–4), 40 mg/day (weeks 4–8), and 60 mg/day (weeks 5–12)). We assessed the relationship between early changes in HAMD-17- anxiety/somatization factor items and depressive remission, as well as whether anxious depression at baseline predicted remission at study endpoint. . Baseline HAMD-17 scores were considered as covariates and the Bonferroni correction (p ≤ .008) was used for multiple comparisons. Results Adjusting for baseline HAMD-17 scores, patients who experienced greater early improvement in somatic symptoms (gastrointestinal) were significantly more likely to attain remission (HAMD-17 < 8) at endpoint than those without early improvement (p = .006). Early changes in the remaining items did not predict remission, nor did anxious depression at baseline. Conclusions Among the anxiety/somatization factor items, only early changes in somatic symptoms (gastrointestinal) predicted remission. Future studies are warranted to further investigate this relationship, as well as that between anxious depression and treatment outcome. PMID:20400905

  14. Very Long Baseline Interferometry Applied to Polar Motion, Relativity and Geodesy. Ph.D. Thesis - Maryland Univ.

    NASA Technical Reports Server (NTRS)

    Ma, C.

    1978-01-01

    The causes and effects of diurnal polar motion are described. An algorithm is developed for modeling the effects on very long baseline interferometry observables. Five years of radio-frequency very long baseline interferometry data from stations in Massachusetts, California, and Sweden are analyzed for diurnal polar motion. It is found that the effect is larger than predicted by McClure. Corrections to the standard nutation series caused by the deformability of the earth have a significant effect on the estimated diurnal polar motion scaling factor and the post-fit residual scatter. Simulations of high precision very long baseline interferometry experiments taking into account both measurement uncertainty and modeled errors are described.

  15. Comparison of Interferometric Time-Series Analysis Techniques with Implications for Future Mission Design

    NASA Astrophysics Data System (ADS)

    Werner, C. L.; Wegmuller, U.; Strozzi, T.; Wiesmann, A.

    2006-12-01

    Principle contributors to the noise in differential SAR interferograms are temporal phase stability of the surface, geometry relating to baseline and surface slope, and propagation path delay variations due to tropospheric water vapor and the ionosphere. Time series analysis of multiple interferograms generated from a stack of SAR SLC images seeks to determine the deformation history of the surface while reducing errors. Only those scatterers within a resolution element that are stable and coherent for each interferometric pair contribute to the desired deformation signal. Interferograms with baselines exceeding 1/3 the critical baseline have substantial geometrical decorrelation for distributed targets. Short baseline pairs with multiple reference scenes can be combined using least-squares estimation to obtain a global deformation solution. Alternately point-like persistent scatterers can be identified in scenes that do not exhibit geometrical decorrelation associated with large baselines. In this approach interferograms are formed from a stack of SAR complex images using a single reference scene. Stable distributed scatter pixels are excluded however due to the presence of large baselines. We apply both point- based and short-baseline methodologies and compare results for a stack of fine-beam Radarsat data acquired in 2002-2004 over a rapidly subsiding oil field near Lost Hills, CA. We also investigate the density of point-like scatters with respect to image resolution. The primary difficulty encountered when applying time series methods is phase unwrapping errors due to spatial and temporal gaps. Phase unwrapping requires sufficient spatial and temporal sampling. Increasing the SAR range bandwidth increases the range resolution as well as increasing the critical interferometric baseline that defines the required satellite orbital tube diameter. Sufficient spatial sampling also permits unwrapping because of the reduced phase/pixel gradient. Short time intervals further reduce the differential phase due to deformation when the deformation is continuous. Lower frequency systems (L- vs. C-Band) substantially improve the ability to unwrap the phase correctly by directly reducing both interferometric phase amplitude and temporal decorrelation.

  16. SUBTHRESHOLD MICROPULSE DIODE LASER VERSUS CONVENTIONAL LASER PHOTOCOAGULATION FOR DIABETIC MACULAR EDEMA: A Meta-Analysis of Randomized Controlled Trials.

    PubMed

    Chen, Guohai; Tzekov, Radouil; Li, Wensheng; Jiang, Fangzheng; Mao, Sihong; Tong, Yuhua

    2016-11-01

    To evaluate the relative efficacy of subthreshold micropulse diode laser versus conventional laser photocoagulation for the treatment of diabetic macular edema. A comprehensive literature search was conducted to find relevant randomized controlled trials (RCTs). Efficacy estimates were determined by comparing weighted mean differences of the mean change of best-corrected visual acuity and central macular thickness from baseline. Six RCTs were selected for this meta-analysis, including 398 eyes (203 eyes in the subthreshold micropulse diode laser group and 195 eyes in the conventional laser group). Subthreshold micropulse diode laser was superior to conventional laser in terms of mean change of logMAR best-corrected visual acuity at 3, 9, and 12 months after treatment (P = 0.02; P = 0.04, and P = 0.03, respectively), and it showed a similar trend at 6 months (P = 0.05). Although, there was no significant difference in terms of mean change in central macular thickness from baseline to 3, 6, 9, or 12 months (P = 0.80; P = 0.20; P = 0.88, and P = 0.86, respectively). Subthreshold micropulse diode laser treatment resulted in better visual acuity compared with conventional laser, although the differences before 12 months are likely to be too small to be of clinical relevance and may be dependent on baseline best-corrected visual acuity. The two types of treatment seem to have similar anatomical outcome.

  17. Reducing Variability in Orthogonal Reformatted Image Quality Associated With Axial Long-z-Axis CT Angiography.

    PubMed

    Stein, Erica B; Liu, Peter S; Kazerooni, Ella A; Barber, Karen; Davenport, Matthew S

    2016-12-01

    The objective of our study was to reduce variation in image quality of orthogonal reformatted images generated from long-z-axis CT angiography (CTA) studies of the upper and lower extremities. Upper and lower extremity CTA studies were targeted at a single health care system. A correctly performed CTA examination was defined as one that met the following three criteria: Sagittal and coronal reformats were obtained, a high-resolution matrix greater than 512 × 512 was used, and reformatted images were available in a distance-measurable format. Baseline data were collected from February 1, 2014, through September 30, 2014. Corrective actions were implemented during three consecutive plan-do-check-act (PDCA) cycles from October 1, 2014, through July 31, 2015, that addressed human, technical, and systematic variations. A 3-month maintenance period followed in which no intervention was performed. Longitudinal data were analyzed monthly using a statistical process control chart (p-chart). The total number of long-z-axis extremity CTA studies analyzed was as follows: 351 CTA studies were analyzed at baseline, 94 at the first PDCA cycle, 92 at the second PDCA cycle, 114 at the third PDCA cycle, and 138 during the maintenance period. The monthly rate of correctly performed studies ranged from 7% to 51% (mean, 38% ± 13% [SD]) during the baseline period, 32-59% (mean, 46% ± 14%) during the first PDCA cycle, 40-81% (mean, 61% ± 21%) during the second PDCA cycle, and 80-82% (mean, 81% ± 0.9%) during the third PDCA cycle. The monthly rate improved to 90-91% (mean, 91% ± 0.5%) during the maintenance period. The upper and lower control limits of the p-chart were upshifted after the second and third PDCA cycles. Correcting systematic and technical variations led to the greatest improvements in reformat accuracy. Obtaining consistently and correctly reformatted images from long-z-axis CTA studies is achievable using iterative PDCA cycles.

  18. Factors Predicting Visual Acuity Outcome in Intermediate, Posterior, and Panuveitis: The Multicenter Uveitis Steroid Treatment (MUST) Trial.

    PubMed

    Kempen, John H; Van Natta, Mark L; Altaweel, Michael M; Dunn, James P; Jabs, Douglas A; Lightman, Susan L; Thorne, Jennifer E; Holbrook, Janet T

    2015-12-01

    To identify factors associated with best-corrected visual acuity (BCVA) presentation and 2-year outcome in 479 intermediate, posterior, and panuveitic eyes. Cohort study using randomized controlled trial data. Multicenter Uveitis Steroid Treatment (MUST) Trial masked BCVA measurements at baseline and at 2 years follow-up used gold-standard methods. Twenty-three clinical centers documented characteristics per protocol, which were evaluated as potential predictive factors for baseline BCVA and 2-year change in BCVA. Baseline factors significantly associated with reduced BCVA included age ≥50 vs <50 years; posterior vs intermediate uveitis; uveitis duration >10 vs <6 years; anterior chamber (AC) flare >grade 0; cataract; macular thickening; and exudative retinal detachment. Over 2 years, eyes better than 20/50 and 20/50 or worse at baseline improved, on average, by 1 letter (P = .52) and 10 letters (P < .001), respectively. Both treatment groups and all sites of uveitis improved similarly. Factors associated with improved BCVA included resolution of active AC cells, resolution of macular thickening, and cataract surgery in an initially cataractous eye. Factors associated with worsening BCVA included longer duration of uveitis (6-10 or >10 vs <6 years), incident AC flare, cataract at both baseline and follow-up, pseudophakia at baseline, persistence or incidence of vitreous haze, and incidence of macular thickening. Intermediate, posterior, and panuveitis have a similarly favorable prognosis with both systemic and fluocinolone acetonide implant treatment. Eyes with more prolonged/severe inflammatory damage and/or inflammatory findings initially or during follow-up have a worse visual acuity prognosis. The results indicate the value of implementing best practices in managing inflammation. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Trajectories of Substance Use Disorder in Youth After Detention: A 12-Year Longitudinal Study

    PubMed Central

    Welty, Leah J.; Hershfield, Jennifer A.; Abram, Karen M.; Han, Hongyun; Byck, Gayle R.; Teplin, Linda A.

    2016-01-01

    Objective Identify trajectories of substance use disorders (SUDs) in youth during the 12 years after detention, and how gender, race/ethnicity, and age at baseline predict trajectories. Method As part of the Northwestern Juvenile Project, a longitudinal study of 1,829 youth randomly sampled from detention in Chicago, Illinois, 1995–1998, participants were re-interviewed in the community or correctional facilities up to 9 times over 12 years. Independent interviewers assessed SUDs using the Diagnostic Interview Schedule for Children 2.3 (baseline) and the Diagnostic Interview Schedule IV (follow-ups). Primary outcome was a mutually exclusive 5-category typology of disorder: no SUD, alcohol alone, marijuana alone, comorbid alcohol and marijuana, or “other” illicit (“hard”) drug. We estimated trajectories using growth mixture models with a 3-category ordinal variable derived from the typology. Results During the 12-year follow-up, 19.6% of youth did not have an SUD. The remaining 81.4% were in 3 trajectory classes. Class 1 (24.5%), a bell-shaped trajectory, peaked 5 years after baseline when 42.7% had an SUD and 12.5% had comorbid/“other” illicit drug disorders. Class 2 (41.3%) had higher prevalence of SUD at baseline (73.8%). Although prevalence decreased over time, 23.5% had an SUD 12 years later. Class 3 (14.6%), the most serious and persistent trajectory, had the highest prevalence of comorbid/“other” illicit drug disorders—52.1% at baseline and 17.4% 12 years later. Males, Hispanics, non-Hispanic whites, and youth who were older at baseline (detention) had the worst outcomes. Conclusion Gender, race/ethnicity, and age at detention predict trajectories of SUDs in delinquent youth. Findings provide an empirical basis for child psychiatry to address health disparities and improve prevention. PMID:28117060

  20. A randomized comparison of patients' understanding of number needed to treat and other common risk reduction formats.

    PubMed

    Sheridan, Stacey L; Pignone, Michael P; Lewis, Carmen L

    2003-11-01

    Commentators have suggested that patients may understand quantitative information about treatment benefits better when they are presented as numbers needed to treat (NNT) rather than as absolute or relative risk reductions. To determine whether NNT helps patients interpret treatment benefits better than absolute risk reduction (ARR), relative risk reduction (RRR), or a combination of all three of these risk reduction presentations (COMBO). Randomized cross-sectional survey. University internal medicine clinic. Three hundred fifty-seven men and women, ages 50 to 80, who presented for health care. Subjects were given written information about the baseline risk of a hypothetical "disease Y" and were asked (1) to compare the benefits of two drug treatments for disease Y, stating which provided more benefit; and (2) to calculate the effect of one of those drug treatments on a given baseline risk of disease. Risk information was presented to each subject in one of four randomly allocated risk formats: NNT, ARR, RRR, or COMBO. When asked to state which of two treatments provided more benefit, subjects who received the RRR format responded correctly most often (60% correct vs 43% for COMBO, 42% for ARR, and 30% for NNT, P =.001). Most subjects were unable to calculate the effect of drug treatment on the given baseline risk of disease, although subjects receiving the RRR and ARR formats responded correctly more often (21% and 17% compared to 7% for COMBO and 6% for NNT, P =.004). Patients are best able to interpret the benefits of treatment when they are presented in an RRR format with a given baseline risk of disease. ARR also is easily interpreted. NNT is often misinterpreted by patients and should not be used alone to communicate risk to patients.

  1. Real-world cardiovascular assessment of mirabegron treatment in patients with overactive bladder and concomitant cardiovascular disease: Results of a Japanese post-marketing study.

    PubMed

    Katoh, Takao; Kuwamoto, Kana; Kato, Daisuke; Kuroishi, Kentarou

    2016-12-01

    To assess the effect of 25 or 50 mg mirabegron on cardiovascular end-points and adverse drug reactions in real-world Japanese patients with overactive bladder and cardiovascular disease. Participants had overactive bladder, a history of/coexisting cardiovascular disease and a 12-lead electrocardiogram carried out ≤7 days before initiating 4 weeks of mirabegron treatment. Patients with "serious cardiovascular disease" (class III or IV on the New York Heart Association functional classification and further confirmed by expert analysis) were excluded. Patient demographics, physical characteristics and cardiovascular history were recorded. After 4 weeks, patients underwent another electrocardiogram. Incidence of cardiovascular adverse drug reactions and change from baseline in electrocardiogram parameters (RR, PR, QRS intervals, Fridericia's corrected QT and heart rate) were assessed. Of 316 patients registered, 236 met criteria and had baseline/post-dose electrocardiograms: 61.9% male; 60.2% aged ≥75 years; 93.6% with coexisting cardiovascular disease, notably, arrhythmia (67.8%) and angina pectoris (19.1%). Starting mirabegron daily doses were 25 mg (19.9%) or 50 mg (80.1%). The incidence of cardiovascular adverse drug reactions was 5.51%. After 4 weeks, the mean heart rate increased by 1.24 b.p.m. (statistically significant, but clinically acceptable as per previous trials). No significant changes were observed in PR, QRS or Fridericia's corrected QT. No significant correlations in the total population or age-/sex-segregated subgroups were observed between baseline Fridericia's corrected QT and change at 4 weeks. No correlation for heart rate versus change from baseline heart rate with treatment was observed. Mirabegron was well tolerated in real-world Japanese patients with overactive bladder and coexisting cardiovascular disease. No unexpected cardiovascular safety concerns were observed. © 2016 The Japanese Urological Association.

  2. [Raman spectroscopy fluorescence background correction and its application in clustering analysis of medicines].

    PubMed

    Chen, Shan; Li, Xiao-ning; Liang, Yi-zeng; Zhang, Zhi-min; Liu, Zhao-xia; Zhang, Qi-ming; Ding, Li-xia; Ye, Fei

    2010-08-01

    During Raman spectroscopy analysis, the organic molecules and contaminations will obscure or swamp Raman signals. The present study starts from Raman spectra of prednisone acetate tablets and glibenclamide tables, which are acquired from the BWTek i-Raman spectrometer. The background is corrected by R package baselineWavelet. Then principle component analysis and random forests are used to perform clustering analysis. Through analyzing the Raman spectra of two medicines, the accurate and validity of this background-correction algorithm is checked and the influences of fluorescence background on Raman spectra clustering analysis is discussed. Thus, it is concluded that it is important to correct fluorescence background for further analysis, and an effective background correction solution is provided for clustering or other analysis.

  3. Reliable estimation of orbit errors in spaceborne SAR interferometry. The network approach

    NASA Astrophysics Data System (ADS)

    Bähr, Hermann; Hanssen, Ramon F.

    2012-12-01

    An approach to improve orbital state vectors by orbit error estimates derived from residual phase patterns in synthetic aperture radar interferograms is presented. For individual interferograms, an error representation by two parameters is motivated: the baseline error in cross-range and the rate of change of the baseline error in range. For their estimation, two alternatives are proposed: a least squares approach that requires prior unwrapping and a less reliable gridsearch method handling the wrapped phase. In both cases, reliability is enhanced by mutual control of error estimates in an overdetermined network of linearly dependent interferometric combinations of images. Thus, systematic biases, e.g., due to unwrapping errors, can be detected and iteratively eliminated. Regularising the solution by a minimum-norm condition results in quasi-absolute orbit errors that refer to particular images. For the 31 images of a sample ENVISAT dataset, orbit corrections with a mutual consistency on the millimetre level have been inferred from 163 interferograms. The method itself qualifies by reliability and rigorous geometric modelling of the orbital error signal but does not consider interfering large scale deformation effects. However, a separation may be feasible in a combined processing with persistent scatterer approaches or by temporal filtering of the estimates.

  4. Gravity gradient preprocessing at the GOCE HPF

    NASA Astrophysics Data System (ADS)

    Bouman, J.; Rispens, S.; Gruber, T.; Schrama, E.; Visser, P.; Tscherning, C. C.; Veicherts, M.

    2009-04-01

    One of the products derived from the GOCE observations are the gravity gradients. These gravity gradients are provided in the Gradiometer Reference Frame (GRF) and are calibrated in-flight using satellite shaking and star sensor data. In order to use these gravity gradients for application in Earth sciences and gravity field analysis, additional pre-processing needs to be done, including corrections for temporal gravity field signals to isolate the static gravity field part, screening for outliers, calibration by comparison with existing external gravity field information and error assessment. The temporal gravity gradient corrections consist of tidal and non-tidal corrections. These are all generally below the gravity gradient error level, which is predicted to show a 1/f behaviour for low frequencies. In the outlier detection the 1/f error is compensated for by subtracting a local median from the data, while the data error is assessed using the median absolute deviation. The local median acts as a high-pass filter and it is robust as is the median absolute deviation. Three different methods have been implemented for the calibration of the gravity gradients. All three methods use a high-pass filter to compensate for the 1/f gravity gradient error. The baseline method uses state-of-the-art global gravity field models and the most accurate results are obtained if star sensor misalignments are estimated along with the calibration parameters. A second calibration method uses GOCE GPS data to estimate a low degree gravity field model as well as gravity gradient scale factors. Both methods allow to estimate gravity gradient scale factors down to the 10-3 level. The third calibration method uses high accurate terrestrial gravity data in selected regions to validate the gravity gradient scale factors, focussing on the measurement band. Gravity gradient scale factors may be estimated down to the 10-2 level with this method.

  5. Preprocessing of gravity gradients at the GOCE high-level processing facility

    NASA Astrophysics Data System (ADS)

    Bouman, Johannes; Rispens, Sietse; Gruber, Thomas; Koop, Radboud; Schrama, Ernst; Visser, Pieter; Tscherning, Carl Christian; Veicherts, Martin

    2009-07-01

    One of the products derived from the gravity field and steady-state ocean circulation explorer (GOCE) observations are the gravity gradients. These gravity gradients are provided in the gradiometer reference frame (GRF) and are calibrated in-flight using satellite shaking and star sensor data. To use these gravity gradients for application in Earth scienes and gravity field analysis, additional preprocessing needs to be done, including corrections for temporal gravity field signals to isolate the static gravity field part, screening for outliers, calibration by comparison with existing external gravity field information and error assessment. The temporal gravity gradient corrections consist of tidal and nontidal corrections. These are all generally below the gravity gradient error level, which is predicted to show a 1/ f behaviour for low frequencies. In the outlier detection, the 1/ f error is compensated for by subtracting a local median from the data, while the data error is assessed using the median absolute deviation. The local median acts as a high-pass filter and it is robust as is the median absolute deviation. Three different methods have been implemented for the calibration of the gravity gradients. All three methods use a high-pass filter to compensate for the 1/ f gravity gradient error. The baseline method uses state-of-the-art global gravity field models and the most accurate results are obtained if star sensor misalignments are estimated along with the calibration parameters. A second calibration method uses GOCE GPS data to estimate a low-degree gravity field model as well as gravity gradient scale factors. Both methods allow to estimate gravity gradient scale factors down to the 10-3 level. The third calibration method uses high accurate terrestrial gravity data in selected regions to validate the gravity gradient scale factors, focussing on the measurement band. Gravity gradient scale factors may be estimated down to the 10-2 level with this method.

  6. Atmospheric corrections in interferometric synthetic aperture radar surface deformation - a case study of the city of Mendoza, Argentina

    NASA Astrophysics Data System (ADS)

    Balbarani, S.; Euillades, P. A.; Euillades, L. D.; Casu, F.; Riveros, N. C.

    2013-09-01

    Differential interferometry is a remote sensing technique that allows studying crustal deformation produced by several phenomena like earthquakes, landslides, land subsidence and volcanic eruptions. Advanced techniques, like small baseline subsets (SBAS), exploit series of images acquired by synthetic aperture radar (SAR) sensors during a given time span. Phase propagation delay in the atmosphere is the main systematic error of interferometric SAR measurements. It affects differently images acquired at different days or even at different hours of the same day. So, datasets acquired during the same time span from different sensors (or sensor configuration) often give diverging results. Here we processed two datasets acquired from June 2010 to December 2011 by COSMO-SkyMed satellites. One of them is HH-polarized, and the other one is VV-polarized and acquired on different days. As expected, time series computed from these datasets show differences. We attributed them to non-compensated atmospheric artifacts and tried to correct them by using ERA-Interim global atmospheric model (GAM) data. With this method, we were able to correct less than 50% of the scenes, considering an area where no phase unwrapping errors were detected. We conclude that GAM-based corrections are not enough for explaining differences in computed time series, at least in the processed area of interest. We remark that no direct meteorological data for the GAM-based corrections were employed. Further research is needed in order to understand under what conditions this kind of data can be used.

  7. Errata, nursing homes. Budget percentiles for baseline and redesigned commercial type buildings: cities with try weather tapes; based on resource utilization factors (RUF); based on price weighting factors (PWF)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Corrected data are presented for the P50 Redesign figure for nursing homes in the following documents in the series entitled Budget Percentiles for Baseline and Redesigned Commercial Type Buildings: For Cities with TRY Weather Tapes, Based on Price Weighing Factors (PWF), and Based on Resource Utilization Factors (RUF). (MCW)

  8. Combined cGPS and InSAR time series for observing subsidence in the southern Central Valley due to groundwater exploitation

    NASA Astrophysics Data System (ADS)

    Neely, W.; Borsa, A. A.; Silverii, F.

    2017-12-01

    Recent droughts have increased reliance on groundwater for agricultural production in California's Central Valley. Using Interferometric Synthetic Aperture Radar (InSAR), we observe upwards of 25 cm/yr of subsidence from November 2014 to February 2017 due to intense pumping. However, these observations are contaminated by atmospheric noise and orbital errors. We present a novel method for correcting long wavelength errors in InSAR deformation estimates using time series from continuous Global Positioning System (cGPS) stations within the SAR footprint, which we apply to C-band data from the Sentinel mission. We test our method using 49 SAR acquisitions from the Sentinel 1 satellites and 107 cGPS times series from the Geodesy Advancing Geoscience and EarthScope (GAGE) network in southern Central Valley. We correct each interferogram separately, implementing an intermittent Small Baseline Subset (ISBAS) technique to produce a time series of line-of-sight surface motion from 276 InSAR pairs. To estimate the vertical component of this motion, we remove horizontal tectonic displacements predicted by the Southern California Earthquake Center's (SCEC) Community Geodetic Model. We validate our method by comparing the corrected InSAR results with independent cGPS data and find a marked improvement in agreement between the two data sets, particularly in the deformation rates. Using this technique, we characterize the time evolution of surface vertical deformation in the southern Central Valley related to human exploitation of local groundwater resources. This methodology is applicable to data from other SAR satellites, including ALOS-2 and the upcoming US-India NISAR mission.

  9. Effect of baseline corrections on response spectra for two recordings of the 1999 Chi-Chi, Taiwan, earthquake

    USGS Publications Warehouse

    Boore, David M.

    1999-01-01

    Displacements derived from the accelerogram recordings of the 1999 Chi-Chi, Taiwan earthquake at stations TCU078 and TCU129 show drifts when only a simple baseline derived from the pre-event portion of the record is removed from the records. The appearance of the velocity and displacement records suggests that changes in the zero-level of the acceleration are responsible for these drifts. The source of the shifts in zero-level are unknown, but might include tilts in the instruments or the response of the instruments to strong shaking. This note illustrates the effect on the velocity, displacement, and response spectra of several schemes for accounting for these baseline shifts. The most important conclusion for earthquake engineering purposes is that the response spectra for periods less than about 20 sec are unaffected by the baseline correction. The results suggest, however, that staticdisplac ements estimated from the instruments should be used with caution. Although limited to the analysis of only two recordings, the results may have more general significance both for the many other recordings of this earthquake and for data that will be obtained in the future from similar high-quality accelerograph networks now being installed or soon to be installed in many parts of the world.

  10. Palbociclib has no clinically relevant effect on the QTc interval in patients with advanced breast cancer.

    PubMed

    Durairaj, Chandrasekar; Ruiz-Garcia, Ana; Gauthier, Eric R; Huang, Xin; Lu, Dongrui R; Hoffman, Justin T; Finn, Richard S; Joy, Anil A; Ettl, Johannes; Rugo, Hope S; Zheng, Jenny; Wilner, Keith D; Wang, Diane D

    2018-03-01

    The aim of this study was to assess the potential effects of palbociclib in combination with letrozole on QTc. PALOMA-2, a phase 3, randomized, double-blind, placebo-controlled trial, compared palbociclib plus letrozole with placebo plus letrozole in postmenopausal women with estrogen receptor-positive, human epidermal growth factor receptor 2-negative advanced breast cancer. The study included a QTc evaluation substudy carried out as a definitive QT interval prolongation assessment for palbociclib. Time-matched triplicate ECGs were performed at 0, 2, 4, 6, and 8 h at baseline (Day 0) and on Cycle 1 Day 14. Additional ECGs were collected from all patients for safety monitoring. The QT interval was corrected for heart rate using Fridericia's correction (QTcF), Bazett's correction (QTcB), and a study-specific correction factor (QTcS). In total, 666 patients were randomized 2 : 1 to palbociclib plus letrozole or placebo plus letrozole. Of these, 125 patients were enrolled in the QTc evaluation substudy. No patients in the palbociclib plus letrozole arm of the substudy (N=77) had a maximum postbaseline QTcS or QTcF value of ≥ 480 ms, or a maximum increase from clock time-matched baseline for QTcS or QTcF values of ≥ 60 ms. The upper bounds of the one-sided 95% confidence interval for the mean change from time-matched baseline for QTcS, QTcF, and QTcB at all time points and at steady-state Cmax following repeated administration of 125 mg palbociclib were less than 10 ms. Palbociclib, when administered with letrozole at the recommended therapeutic dosing regimen, did not prolong the QT interval to a clinically relevant extent.

  11. Effect of an Ergonomics-Based Educational Intervention Based on Transtheoretical Model in Adopting Correct Body Posture Among Operating Room Nurses

    PubMed Central

    Moazzami, Zeinab; Dehdari, Tahere; Taghdisi, Mohammad Hosein; Soltanian, Alireza

    2016-01-01

    Background: One of the preventive strategies for chronic low back pain among operating room nurses is instructing proper body mechanics and postural behavior, for which the use of the Transtheoretical Model (TTM) has been recommended. Methods: Eighty two nurses who were in the contemplation and preparation stages for adopting correct body posture were randomly selected (control group = 40, intervention group = 42). TTM variables and body posture were measured at baseline and again after 1 and 6 months after the intervention. A four-week ergonomics educational intervention based on TTM variables was designed and conducted for the nurses in the intervention group. Results: Following the intervention, a higher proportion of nurses in the intervention group moved into the action stage (p < 0.05). Mean scores of self-efficacy, pros, experimental processes and correct body posture were also significantly higher in the intervention group (p < 0.05). No significant differences were found in the cons and behavioral processes, except for self-liberation, between the two groups (p > 0.05) after the intervention. Conclusions: The TTM provides a suitable framework for developing stage-based ergonomics interventions for postural behavior. PMID:26925897

  12. A combined method to calculate co-seismic displacements through strong motion acceleration baseline correction

    NASA Astrophysics Data System (ADS)

    Zhan, W.; Sun, Y.

    2015-12-01

    High frequency strong motion data, especially near field acceleration data, have been recorded widely through different observation station systems among the world. Due to tilting and a lot other reasons, recordings from these seismometers usually have baseline drift problems when big earthquake happens. It is hard to obtain a reasonable and precision co-seismic displacement through simply double integration. Here presents a combined method using wavelet transform and several simple liner procedures. Owning to the lack of dense high rate GNSS data in most of region of the world, we did not contain GNSS data in this method first but consider it as an evaluating mark of our results. This semi-automatic method unpacks a raw signal into two portions, a summation of high ranks and a low ranks summation using a cubic B-spline wavelet decomposition procedure. Independent liner treatments are processed against these two summations, which are then composed together to recover useable and reasonable result. We use data of 2008 Wenchuan earthquake and choose stations with a near GPS recording to validate this method. Nearly all of them have compatible co-seismic displacements when compared with GPS stations or field survey. Since seismometer stations and GNSS stations from observation systems in China are sometimes quite far from each other, we also test this method with some other earthquakes (1999 Chi-Chi earthquake and 2011 Tohoku earthquake). And for 2011 Tohoku earthquake, we will introduce GPS recordings to this combined method since the existence of a dense GNSS systems in Japan.

  13. Visual outcomes after spectacles treatment in children with bilateral high refractive amblyopia.

    PubMed

    Lin, Pei-Wen; Chang, Hsueh-Wen; Lai, Ing-Chou; Teng, Mei-Ching

    2016-11-01

    The aim was to investigate the visual outcomes of treatment with spectacles for bilateral high refractive amblyopia in children three to eight years of age. Children with previously untreated bilateral refractive amblyopia were enrolled. Bilateral high refractive amblyopia was defined as visual acuity (VA) being worse than 6/9 in both eyes in the presence of 5.00 D or more of hyperopia, 5.00 D or more of myopia and 2.00 D or more of astigmatism. Full myopic and astigmatic refractive errors were corrected, and the hyperopic refractive errors were corrected within 1.00 D of the full correction. All children received visual assessments at four-weekly intervals. VA, Worth four-dot test and Randot preschool stereotest were assessed at baseline and every four weeks for two years. Twenty-eight children with previously untreated bilateral high refractive amblyopia were enrolled. The mean VA at baseline was 0.39 ± 0.24 logMAR and it significantly improved to 0.21, 0.14, 0.11, 0.05 and 0.0 logMAR at four, eight, 12, 24 weeks and 18 months, respectively (all p = 0.001). The mean stereoacuity (SA) was 1,143 ± 617 arcsec at baseline and it significantly improved to 701, 532, 429, 211 and 98 arcsec at four, eight, 12, 24 weeks and 18 months, respectively (all p = 0.001). The time interval for VA achieving 6/6 was significantly shorter in the eyes of low spherical equivalent (SE) (-2.00 D < SE < +2.00 D) than in those of high SE (SE > +2.00 D) (3.33 ± 2.75 months versus 8.11 ± 4.56 months, p = 0.0005). All subjects had normal fusion on Worth four-dot test at baseline and all follow-up visits. Refractive correction with good spectacles compliance improves VA and SA in young children with bilateral high refractive amblyopia. Patients with greater amounts of refractive error will achieve resolution of amblyopia with a longer time. © 2016 Optometry Australia.

  14. [Achievement of the noninvasive measurement for human blood glucose with NIR diffusion reflectance spectrum method].

    PubMed

    Zhang, Hong-yan; Ding, Dong; Song, Li-qiang; Gu, Lin-na; Yang, Peng; Tang, Yu-guo

    2005-06-01

    The noninvasive measurement of human blood glucose was achieved with NIR diffusion reflectance spectrum method. The thumb fingertip NIR diffusion reflectance spectra of six different age healthy volunteers were collected using Nexus-870 and its NIR fiber port smart accessory. The test was implemented with changing the blood glucose concentration for the limosis and satiation of every volunteer. The calibration model was set up using PLS method with the smoothing, baseline correction and first derivatives pretreatment spectrum in the 7500-8500 cm(-1) region for single volunteer, the same age combination and that of different age. When the spectrum was obtained, the actual blood glucose value of every spectrun sample was demarcated using ultraviolet spectrophotometer. The correlation between the calibration value and true value for single volunteer is better than that for the combination of volunteers, the correlative coefficients are all over 0.90471, RMSECs are all less than 0.171.

  15. Correct machine learning on protein sequences: a peer-reviewing perspective.

    PubMed

    Walsh, Ian; Pollastri, Gianluca; Tosatto, Silvio C E

    2016-09-01

    Machine learning methods are becoming increasingly popular to predict protein features from sequences. Machine learning in bioinformatics can be powerful but carries also the risk of introducing unexpected biases, which may lead to an overestimation of the performance. This article espouses a set of guidelines to allow both peer reviewers and authors to avoid common machine learning pitfalls. Understanding biology is necessary to produce useful data sets, which have to be large and diverse. Separating the training and test process is imperative to avoid over-selling method performance, which is also dependent on several hidden parameters. A novel predictor has always to be compared with several existing methods, including simple baseline strategies. Using the presented guidelines will help nonspecialists to appreciate the critical issues in machine learning. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  16. Estimation of group means when adjusting for covariates in generalized linear models.

    PubMed

    Qu, Yongming; Luo, Junxiang

    2015-01-01

    Generalized linear models are commonly used to analyze categorical data such as binary, count, and ordinal outcomes. Adjusting for important prognostic factors or baseline covariates in generalized linear models may improve the estimation efficiency. The model-based mean for a treatment group produced by most software packages estimates the response at the mean covariate, not the mean response for this treatment group for the studied population. Although this is not an issue for linear models, the model-based group mean estimates in generalized linear models could be seriously biased for the true group means. We propose a new method to estimate the group mean consistently with the corresponding variance estimation. Simulation showed the proposed method produces an unbiased estimator for the group means and provided the correct coverage probability. The proposed method was applied to analyze hypoglycemia data from clinical trials in diabetes. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Development and validation of an MEKC method for determination of nitrogen-containing drugs in pharmaceutical preparations.

    PubMed

    Buiarelli, Francesca; Coccioli, Franco; Jasionowska, Renata; Terracciano, Alessandro

    2008-09-01

    A fast and accurate micellar electrokinetic capillary chromatography method was developed for quality control of pharmaceutical preparations containing cold remedies as acetaminophen, salicylamide, caffeine, phenylephrine, pseudoephedrine, norephedrine and chlorpheniramine. The method optimization was realized on a Beckman P/ACE System MDQ instrument. The baseline separation of seven analytes was performed in an uncoated fused silica capillary internal diameter (ID)=50 microm using tris-borate (20 mM, pH=8.5) containing sodium dodecyl sulphate 30 mM BGE. On line-UV detection at 214 nm was performed and the applied voltage was 10 kV. The operating temperature was 25 degrees C. After experimental conditions optimization, the proposed method was validated. The evaluated parameters were: precision of migration time and of corrected peak area ratio, linearity range, limit of detection, limit of quantification, accuracy (recovery), ruggedness and applicability. The method was then successfully applied for the analysis of three pharmaceutical preparations containing some of the analytes listed before.

  18. Fluorescence background removal method for biological Raman spectroscopy based on empirical mode decomposition.

    PubMed

    Leon-Bejarano, Maritza; Dorantes-Mendez, Guadalupe; Ramirez-Elias, Miguel; Mendez, Martin O; Alba, Alfonso; Rodriguez-Leyva, Ildefonso; Jimenez, M

    2016-08-01

    Raman spectroscopy of biological tissue presents fluorescence background, an undesirable effect that generates false Raman intensities. This paper proposes the application of the Empirical Mode Decomposition (EMD) method to baseline correction. EMD is a suitable approach since it is an adaptive signal processing method for nonlinear and non-stationary signal analysis that does not require parameters selection such as polynomial methods. EMD performance was assessed through synthetic Raman spectra with different signal to noise ratio (SNR). The correlation coefficient between synthetic Raman spectra and the recovered one after EMD denoising was higher than 0.92. Additionally, twenty Raman spectra from skin were used to evaluate EMD performance and the results were compared with Vancouver Raman algorithm (VRA). The comparison resulted in a mean square error (MSE) of 0.001554. High correlation coefficient using synthetic spectra and low MSE in the comparison between EMD and VRA suggest that EMD could be an effective method to remove fluorescence background in biological Raman spectra.

  19. Convolutional neural networks for vibrational spectroscopic data analysis.

    PubMed

    Acquarelli, Jacopo; van Laarhoven, Twan; Gerretzen, Jan; Tran, Thanh N; Buydens, Lutgarde M C; Marchiori, Elena

    2017-02-15

    In this work we show that convolutional neural networks (CNNs) can be efficiently used to classify vibrational spectroscopic data and identify important spectral regions. CNNs are the current state-of-the-art in image classification and speech recognition and can learn interpretable representations of the data. These characteristics make CNNs a good candidate for reducing the need for preprocessing and for highlighting important spectral regions, both of which are crucial steps in the analysis of vibrational spectroscopic data. Chemometric analysis of vibrational spectroscopic data often relies on preprocessing methods involving baseline correction, scatter correction and noise removal, which are applied to the spectra prior to model building. Preprocessing is a critical step because even in simple problems using 'reasonable' preprocessing methods may decrease the performance of the final model. We develop a new CNN based method and provide an accompanying publicly available software. It is based on a simple CNN architecture with a single convolutional layer (a so-called shallow CNN). Our method outperforms standard classification algorithms used in chemometrics (e.g. PLS) in terms of accuracy when applied to non-preprocessed test data (86% average accuracy compared to the 62% achieved by PLS), and it achieves better performance even on preprocessed test data (96% average accuracy compared to the 89% achieved by PLS). For interpretability purposes, our method includes a procedure for finding important spectral regions, thereby facilitating qualitative interpretation of results. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Detection of BCG bacteria using a magnetoresistive biosensor: A step towards a fully electronic platform for tuberculosis point-of-care detection.

    PubMed

    Barroso, Teresa G; Martins, Rui C; Fernandes, Elisabete; Cardoso, Susana; Rivas, José; Freitas, Paulo P

    2018-02-15

    Tuberculosis is one of the major public health concerns. This highly contagious disease affects more than 10.4 million people, being a leading cause of morbidity by infection. Tuberculosis is diagnosed at the point-of-care by the Ziehl-Neelsen sputum smear microscopy test. Ziehl-Neelsen is laborious, prone to human error and infection risk, with a limit of detection of 10 4 cells/mL. In resource-poor nations, a more practical test, with lower detection limit, is paramount. This work uses a magnetoresistive biosensor to detect BCG bacteria for tuberculosis diagnosis. Herein we report: i) nanoparticle assembly method and specificity for tuberculosis detection; ii) demonstration of proportionality between BCG cell concentration and magnetoresistive voltage signal; iii) application of multiplicative signal correction for systematic effects removal; iv) investigation of calibration effectiveness using chemometrics methods; and v) comparison with state-of-the-art point-of-care tuberculosis biosensors. Results present a clear correspondence between voltage signal and cell concentration. Multiplicative signal correction removes baseline shifts within and between biochip sensors, allowing accurate and precise voltage signal between different biochips. The corrected signal was used for multivariate regression models, which significantly decreased the calibration standard error from 0.50 to 0.03log 10 (cells/mL). Results show that Ziehl-Neelsen detection limits and below are achievable with the magnetoresistive biochip, when pre-processing and chemometrics are used. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Current methodology to assess bioequivalence of levothyroxine sodium products is inadequate.

    PubMed

    Blakesley, Vicky A

    2005-03-30

    Levothyroxine sodium is a drug with a narrow therapeutic index for which an individual patient must have his or her dose carefully titrated to achieve the necessary therapeutic effect. In addition, exogenous levothyroxine cannot be distinguished from the endogenously produced hormone. Since 2004, generic formulations have been approved for the most frequently prescribed brands of levothyroxine sodium. This review examines the methodology and statistical acceptance criteria and summarizes findings of a previously published relative bioavailability study that brings into question the use of standard criteria to assess bioequivalence of levothyroxine sodium. The key findings reviewed were the following: (1) in the absence of baseline correction for endogenous T4 levels, products that differed by as much as 25% to 33% would be declared bioequivalent; (2) the use of baseline correction reduced the likelihood of declaring products bioequivalent when they actually differed by 25% to 33%; (3) even with baseline correction, products that differed by 12.5% would be declared bioequivalent; and (4) there was evidence of significant carryover from one dosing period to the next even with washout periods of up to 53 days. In conclusion, the current recommended methodology in the United States to assess bioequivalence for levothyroxine sodium products is inadequate to differentiate products that differ by 12.5%, a clinically relevant difference. Recommendations are made for modifications to the criteria that could improve the likelihood that products that differ by a clinically significant amount in their bioavailability would not be accepted as bioequivalent.

  2. Estimation and correction of produced light from prompt gamma photons on luminescence imaging of water for proton therapy dosimetry

    NASA Astrophysics Data System (ADS)

    Yabe, Takuya; Komori, Masataka; Toshito, Toshiyuki; Yamaguchi, Mitsutaka; Kawachi, Naoki; Yamamoto, Seiichi

    2018-02-01

    Although the luminescence images of water during proton-beam irradiation using a cooled charge-coupled device camera showed almost the same ranges of proton beams as those measured by an ionization chamber, the depth profiles showed lower Bragg peak intensities than those measured by an ionization chamber. In addition, a broad optical baseline signal was observed in depths that exceed the depth of the Bragg peak. We hypothesize that this broad baseline signal originates from the interaction of proton-induced prompt gamma photons with water. These prompt gamma photons interact with water to form high-energy Compton electrons, which may cause luminescence or Cherenkov emission from depths exceeding the location of the Bragg peak. To clarify this idea, we measured the luminescence images of water during the irradiations of protons in water with minimized parallax errors, and also simulated the produced light by the interactions of prompt gamma photons with water. We corrected the measured depth profiles of the luminescence images by subtracting the simulated distributions of the produced light by the interactions of prompt gamma photons in water. Corrections were also conducted using the estimated depth profiles of the light of the prompt gamma photons, as obtained from the off-beam areas of the luminescence images of water. With these corrections, we successfully obtained depth profiles that have almost identical distributions as the simulated dose distributions for protons. The percentage relative height of the Bragg peak with corrections to that of the simulation data increased to 94% from 80% without correction. Also, the percentage relative offset heights of the deeper part of the Bragg peak with corrections decreased to 0.2%-0.4% from 4% without correction. These results indicate that the luminescence imaging of water has potential for the dose distribution measurements for proton therapy dosimetry.

  3. Prone positioning reduces severe pushing behavior: three case studies

    PubMed Central

    Fujino, Yuji; Amimoto, Kazu; Sugimoto, Satoshi; Fukata, Kazuhiro; Inoue, Masahide; Takahashi, Hidetoshi; Makita, Shigeru

    2016-01-01

    [Purpose] Pushing behavior is classically described as a disorder of body orientation in the coronal plane. Most interventions for pushing behavior have focused on correcting the deviation in vertical perception. However, pushing behavior seems to involve erroneous movements associated with excessive motor output by the non-paretic limbs and trunk. The present study aimed to inhibit muscular hyper-activity by placing the non-paretic limbs and trunk in the prone position. [Subjects and Methods] The subjects of the present study were 3 acute stroke patients with severe pushing behavior. The study consisted of the following 3 phases: baseline, intervention, and follow-up. In addition to conventional therapy, patients received relaxation therapy in the prone position for 10 minutes a day over 2 days. The severity of pushing behavior was assessed using the scale for contraversive pushing, and truncal balance was evaluated using the trunk control test. These assessments were performed before and after the baseline phase, and after the intervention and follow-up phases. [Results] At the baseline phase, both scores were poor. Both scores improved after the intervention and follow-up phases, and all the patients could sit independently. [Conclusion] Relaxation therapy in the prone position might ameliorate pushing behavior and impaired truncal balance. PMID:27799722

  4. Microperimetric Assessment after Epiretinal Membrane Surgery: 4-Year Follow-Up

    PubMed Central

    Dal Vecchio, Marco; Lavia, Carlo; Nassisi, Marco; Grignolo, Federico M.; Fea, Antonio M.

    2016-01-01

    Purpose. To investigate retinal function using microperimetry in patients affected by idiopathic epiretinal membrane (iERM) and cataract who underwent combined surgery: 4-year follow-up. Design. Prospective, interventional case series. Methods. 30 eyes of 30 consecutive patients with iERM and age-related cataract underwent 25-gauge vitrectomy and cataract surgery. At baseline, 90 and 180 days, and 1 and 4 years, we examined retinal mean sensitivity (MS), retinal mean defect (MD), fixation stability, and frequency of microscotomas using MP1 microperimetry. Best-corrected visual acuity (BCVA) and central retinal thickness (CRT) using a spectral domain optical coherence tomography (SD-OCT) were also performed. Results. All patients completed 1-year follow-up, while 23 patients reached last follow-up. Baseline MS and MD (10.48 ± 4.17 and −9.18 ± 4.40 dB) significantly changed at one year (12.33 ± 3.66 and −7.49 ± 3.31 dB, p < 0.01), at four years (14.18 ± 3.46 and −4.66 ± 2.85, p < 0.01), and between one and four years (p < 0.01) after surgery. Compared to baseline, CRT and BCVA significantly changed at one year and remained stable at four years. No variations were observed in fixation stability and frequency of microscotomas compared to baseline. Conclusions. Long-term follow-up using microperimetry seems useful to evaluate patients after iERM surgery: retinal sensitivity changes even when BCVA and CRT remain stable. PMID:27088008

  5. Attenuation correction for flexible magnetic resonance coils in combined magnetic resonance/positron emission tomography imaging.

    PubMed

    Eldib, Mootaz; Bini, Jason; Calcagno, Claudia; Robson, Philip M; Mani, Venkatesh; Fayad, Zahi A

    2014-02-01

    Attenuation correction for magnetic resonance (MR) coils is a new challenge that came about with the development of combined MR and positron emission tomography (PET) imaging. This task is difficult because such coils are not directly visible on either PET or MR acquisitions with current combined scanners and are therefore not easily localized in the field of view. This issue becomes more evident when trying to localize flexible MR coils (eg, cardiac or body matrix coil) that change position and shape from patient to patient and from one imaging session to another. In this study, we proposed a novel method to localize and correct for the attenuation and scatter of a flexible MR cardiac coil, using MR fiducial markers placed on the surface of the coil to allow for accurate registration of a template computed tomography (CT)-based attenuation map. To quantify the attenuation properties of the cardiac coil, a uniform cylindrical water phantom injected with 18F-fluorodeoxyglucose (18F-FDG) was imaged on a sequential MR/PET system with and without the flexible cardiac coil. After establishing the need to correct for the attenuation of the coil, we tested the feasibility of several methods to register a precomputed attenuation map to correct for the attenuation. To accomplish this, MR and CT visible markers were placed on the surface of the cardiac flexible coil. Using only the markers as a driver for registration, the CT image was registered to the reference image through a combination of rigid and deformable registration. The accuracy of several methods was compared for the deformable registration, including B-spline, thin-plate spline, elastic body spline, and volume spline. Finally, we validated our novel approach both in phantom and patient studies. The findings from the phantom experiments indicated that the presence of the coil resulted in a 10% reduction in measured 18F-FDG activity when compared with the phantom-only scan. Local underestimation reached 22% in regions of interest close to the coil. Various registration methods were tested, and the volume spline was deemed to be the most accurate, as measured by the Dice similarity metric. The results of our phantom experiments showed that the bias in the 18F-FDG quantification introduced by the presence of the coil could be reduced by using our registration method. An overestimation of only 1.9% of the overall activity for the phantom scan with the coil attenuation map was measured when compared with the baseline phantom scan without coil. A local overestimation of less than 3% was observed in the ROI analysis when using the proposed method to correct for the attenuation of the flexible cardiac coil. Quantitative results from the patient study agreed well with the phantom findings. We presented and validated an accurate method to localize and register a CT-based attenuation map to correct for the attenuation and scatter of flexible MR coils. This method may be translated to clinical use to produce quantitatively accurate measurements with the use of flexible MR coils during MR/PET imaging.

  6. An analysis on 45° sweep tail angle for blended wing body aircraft to the aerodynamics coefficients by wind tunnel experiment

    NASA Astrophysics Data System (ADS)

    Latif, M. Z. A. Abd; Ahmad, M. A.; Nasir, R. E. Mohd; Wisnoe, W.; Saad, M. R.

    2017-12-01

    This paper presents the analysis of a model from UiTM Blended Wing Body (BWB) UAV, Baseline V that has been tested at UPNM high speed wind tunnel. Baseline V has a unique design due to different NACA sections used for its fuselage, body, wing root, midwing, wingtip, tail root, tail tip and the tail is swept 45° backward. The purpose of this experiment is to study the aerodynamic characteristics when the tail sweeps 45° backward. The experiments are conducted several times using 71.5% scaled down model at about 49.58 m/s airspeed or 25 Hz. The tail angle deflection is fixed and set at zero angle. All the data obtained is analyzed and presented in terms of coefficient of lift, coefficient of drag and also lift-to-drag ratio, and is plotted against various angles of attack. The angles of attack used for this experiments are between -10° to +30°. The blockage correction such as solid blockage, wake blockage and streamline curvature blockage are calculated in order to obtain true performance of the aircraft. From the observation, Baseline V shows that the aircraft tends to stall at around +15°. The maximum L/D ratio achieved for Baseline V is 20.8, however it decreases slightly to 20.7 after blockage corrections.

  7. Elemental calcium intake associated with calcium acetate/calcium carbonate in the treatment of hyperphosphatemia

    PubMed Central

    Wilson, Rosamund J; Copley, J Brian

    2017-01-01

    Background Calcium-based and non-calcium-based phosphate binders have similar efficacy in the treatment of hyperphosphatemia; however, calcium-based binders may be associated with hypercalcemia, vascular calcification, and adynamic bone disease. Scope A post hoc analysis was carried out of data from a 16-week, Phase IV study of patients with end-stage renal disease (ESRD) who switched to lanthanum carbonate monotherapy from baseline calcium acetate/calcium carbonate monotherapy. Of the intent-to-treat population (N=2520), 752 patients with recorded dose data for calcium acetate (n=551)/calcium carbonate (n=201) at baseline and lanthanum carbonate at week 16 were studied. Elemental calcium intake, serum phosphate, corrected serum calcium, and serum intact parathyroid hormone levels were analyzed. Findings Of the 551 patients with calcium acetate dose data, 271 (49.2%) had an elemental calcium intake of at least 1.5 g/day at baseline, and 142 (25.8%) had an intake of at least 2.0 g/day. Mean (95% confidence interval [CI]) serum phosphate levels were 6.1 (5.89, 6.21) mg/dL at baseline and 6.2 (6.04, 6.38) mg/dL at 16 weeks; mean (95% CI) corrected serum calcium levels were 9.3 (9.16, 9.44) mg/dL and 9.2 (9.06, 9.34) mg/dL, respectively. Of the 201 patients with calcium carbonate dose data, 117 (58.2%) had an elemental calcium intake of at least 1.5 g/day, and 76 (37.8%) had an intake of at least 2.0 g/day. Mean (95% CI) serum phosphate levels were 5.8 (5.52, 6.06) mg/dL at baseline and 5.8 (5.53, 6.05) mg/dL at week 16; mean (95% CI) corrected serum calcium levels were 9.7 (9.15, 10.25) mg/dL and 9.2 (9.06, 9.34) mg/dL, respectively. Conclusion Calcium acetate/calcium carbonate phosphate binders, taken to control serum phosphate levels, may result in high levels of elemental calcium intake. This may lead to complications related to calcium balance. PMID:28182142

  8. The relationship between early changes in the HAMD-17 anxiety/somatization factor items and treatment outcome among depressed outpatients.

    PubMed

    Farabaugh, Amy; Mischoulon, David; Fava, Maurizio; Wu, Shirley L; Mascarini, Alessandra; Tossani, Eliana; Alpert, Jonathan E

    2005-03-01

    The 17-item Hamilton Rating Scale for Depression (HAMD-17) Anxiety/Somatization factor includes six items: Anxiety (psychic), Anxiety (somatic), Somatic Symptoms (gastrointestinal), Somatic Symptoms (general), Hypochondriasis and Insight. This study examines the relationship between early changes (defined as those observed between baseline and week 1) in these HAMD-17 Anxiety/Somatization Factor items and treatment outcome among major depressive disorder (MDD) patients who participated in a study comparing the antidepressant efficacy of a standardized extract of hypericum with both placebo and fluoxetine. Following a 1-week, single-blind washout, patients with MDD diagnosed by the Structured Clinical Interview for DSM-IV (SCID) were randomized to 12 weeks of double-blind treatment with hypericum extract (900 mg/day), fluoxetine (20 mg/day) or placebo. The relationship between early changes in HAMD-17 anxiety/somatization factor items and treatment outcome was assessed separately for patients who received study treatment (hypericum or fluoxetine) versus placebo with a logistic regression method. One hundred and thirty-five patients (female 57%, mean age=37.3+/-11.0 years; mean baseline HAMD-17=19.7+/-3.2 years) were randomized to double-blind treatment and were included in the intent-to-treat (ITT) analyses. After adjusting for baseline HAMD-17 scores and for multiple comparisons with the Bonferroni correction, patients who remitted (HAMD-17 score <8) after study treatment had significantly greater early improvement in Somatic Symptoms (General) scores than non-remitters. No other significant differences in early changes were noted for the remaining items between remitters versus non-remitters who received active treatment. For patients treated with placebo, early change was not predictive of remission for any of the items after Bonferroni correction. In conclusion, the presence of early improvement on the HAMD-17 item concerning fatigue and general somatic symptoms is significantly predictive of achieving remission at endpoint with active study treatment but not with placebo.

  9. COMPARISON OF ARTIFICIAL NEOCHORDAE AND NATIVE CHORDAL TRANSFER IN THE REPAIR OF A FLAIL POSTERIOR MITRAL LEAFLET: AN EXPERIMENTAL STUDY

    PubMed Central

    Padala, Muralidhar; Cardinau, Benedicte; Gyoneva, Lazarina I.; Thourani, Vinod H.

    2013-01-01

    BACKGROUND Surgical reconstruction of a flail posterior leaflet is a routine mitral valve repair, the techniques for which have evolved from leaflet resection to leaflet preservation. Artificial ePTFE neochordae are frequently used to stabilize the flail leaflet, and seldom translocation of the native secondary chordae of the valve to the leaflet free edge is used. In this study, we sought to investigate the efficacy of the two techniques to correct posterior leaflet prolapse and reduce mitral regurgitation, and quantify the acute post-repair leaflet kinematics. METHODS Adult porcine mitral valves (N =7) were studied in a pulsatile left heart experimental model in which isolated P2 flail was mimicked by marginal chordal transection. Baseline conditions were established in each valve under normal conditions (control), and followed by induction of isolated P2 flail by transecting the two marginal chordae on the posterior leaflet free edge (disease). The flail posterior leaflet was reconstructed using artificial neochordae (repair 1) and then native chordal translocation (repair 2). Reduction in leaflet flail, changes in mitral regurgitation fraction, leaflet coaptation length, and posterior leaflet mobility were measured using B-mode echocardiography or color doppler. RESULTS At baseline, all the valves were competent with no mitral regurgitation. After transection of the marginal chordae on the posterior leaflet, isolated P2 flail was evident with 13.7±13% regurgitation. Reconstruction with artificial neochordae eliminated leaflet flail and reduced mitral regurgitation to 3.2± 2.8%, and with chordal translocation leaflet flail was corrected and mitral regurgitation was measured at 2.3±2.6%. Using either repair techniques, leaflet coaptation and mobility of the repaired leaflets were adequate and comparable to the baseline measurements. CONCLUSIONS Comparable reduction leaflet flail and regurgitation, and restoration of physiological leaflet coaptation with the two techniques indicates that under acute conditions, use of artificial neochordae or native chordal translocations have similar benefits. PMID:23291143

  10. Home fire safety education for parents of newborns.

    PubMed

    Lehna, Carlee; Fahey, Erin; Janes, Erika G; Rengers, Sharon; Williams, Joseph; Scrivener, Drane; Myers, John

    2015-09-01

    In children under 1 year of age, the proportion of unintentional burns increases with infant age and mobility. Infants are not able to avoid burns and are dependent on parental or adult help. Treatment of burns in young children is expensive in terms of the life-long costs. The purpose of this study was to examine changes in home fire safety (HFS) knowledge and practices over time for parents of newborn children and expecting parents. HFS knowledge of 103 parents was assessed at baseline, immediately after watching a DVD on HFS (recall), and at 2-week follow-up (retention). In addition, the United States Fire Administration (USFA)/Federal Emergency Management Agency (FEMA) Home Safety Checklist which examines HFS practices in the homes was administered. Seventy percent of the participants were Caucasian, 65% were married, and 81% were first-time parents. HFS knowledge increased significantly from baseline to recall (45±12% vs. 87±17% correct responses, p<0.0001), but declined to 75±18% correct at retention. That is, an individual's baseline scores nearly doubled at recall (42±11% change in baseline score), but only increased by 67% at retention (30±15% change in baseline score). For a subsample of parents who completed the USFA Checklist (n=22), the mean percentage of advocated practices followed was 71±11% (range: 40-89%). Using DVDs was an effective educational modality for increasing HFS knowledge. This addressed an important problem of decreasing burns in infants through increasing parent knowledge and HFS practices using a short, inexpensive DVD. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  11. DEM corrections on series of wrapped interferograms as a tool to improve deformation monitoring around Siling Co lake in Tibet.

    NASA Astrophysics Data System (ADS)

    Ducret, Gabriel; Doin, Marie-Pierre; Lasserre, Cécile; Guillaso, Stéphane; Twardzik, Cedric

    2010-05-01

    In order to increase our knowledge on the lithosphere rheological structure under the Tibetan plateau, we study the loading response due to lake Siling Co water level changes. The challenge here is to measure the deformation with an accuracy good enough to obtain a correct sensivity to model parameters. InSAR method in theory allow to observe the spatio-temporal pattern of deformation, however its exploitation is limited by unwrapping difficulties linked with temporal decorrelation and DEM errors in sloppy and partially incoherent areas. This lake is a large endhoreic lake at 4500~m elevation located North of the strike-slip right lateral Gyaring Co fault, and just to the south of the Bangong Nujiang suture zone, on which numerous left-lateral strike slip are branching. The Siling Co lake water level has strongly changed in the past, as testified by numerous traces of palaeo-shorelines, clearly marked until 60 m above present-day level. In the last years, the water level in this lake increased by about 1~m/yr, a remarkably fast rate given the large lake surface (1600~km2). The present-day ground subsidence associated to the water level increase is studied by InSAR using all ERS and Envisat archived data on track 219, obtained through the Dragon cooperation program. We chose to compute 750~km long differential interferograms centered on the lake to provide a good constraint on the reference. A redundant network of small baseline interferograms is computed with perpendicular baseline smaller than 500~m. The coherence is quickly lost with time (over one year), particularly to the North of the lake because of freeze-thaw cycles. Unwrapping thus becomes hazardous in this configuration, and fails on phase jumps created by DEM contrasts. The first work is to improve the simulated elevation field in radar geometry from the Digital Elevation Model (here SRTM) in order to exploit the interferometric phase in layover areas. Then, to estimate DEM error, we mix the Permanent Scattered and Small Baseline methods. The aim is to improve spatial and temporal coherence. We use as a reference strong and stable amplitude points or spatially coherent areas, scattered within the SAR scene. We calculate the relative elevation error of every point in the neighbourhood of reference points. A global inversion allows to perform spatial integration of local errors at the radar image scale. Finally, we evaluate how the DEM correct ion of wrapped interferograms improves the unwrapping step. Furthermore, to help unwrapping we also compute and then remove from the wrapped interferograms the residual orbital trend and the phase-elevation relationship due variations in atmospheric stratification. Stack of unwrapped small baseline interferograms show clearly the average subsidence rate around the lake of about 4 mm/yr associated to the present-day water level increase. To compare the observed deformation to the water level elevation changes, we extract from satellite images in the period 1972 to 2009 the water level changes. The deformation signal is discussed in terms of end-members visco-elastic models of the lithosphere and uppermost mantle.

  12. Special electronic distance meter calibration for precise engineering surveying industrial applications

    NASA Astrophysics Data System (ADS)

    Braun, Jaroslav; Štroner, Martin; Urban, Rudolf

    2015-05-01

    All surveying instruments and their measurements suffer from some errors. To refine the measurement results, it is necessary to use procedures restricting influence of the instrument errors on the measured values or to implement numerical corrections. In precise engineering surveying industrial applications the accuracy of the distances usually realized on relatively short distance is a key parameter limiting the resulting accuracy of the determined values (coordinates, etc.). To determine the size of systematic and random errors of the measured distances were made test with the idea of the suppression of the random error by the averaging of the repeating measurement, and reducing systematic errors influence of by identifying their absolute size on the absolute baseline realized in geodetic laboratory at the Faculty of Civil Engineering CTU in Prague. The 16 concrete pillars with forced centerings were set up and the absolute distances between the points were determined with a standard deviation of 0.02 millimetre using a Leica Absolute Tracker AT401. For any distance measured by the calibrated instruments (up to the length of the testing baseline, i.e. 38.6 m) can now be determined the size of error correction of the distance meter in two ways: Firstly by the interpolation on the raw data, or secondly using correction function derived by previous FFT transformation usage. The quality of this calibration and correction procedure was tested on three instruments (Trimble S6 HP, Topcon GPT-7501, Trimble M3) experimentally using Leica Absolute Tracker AT401. By the correction procedure was the standard deviation of the measured distances reduced significantly to less than 0.6 mm. In case of Topcon GPT-7501 is the nominal standard deviation 2 mm, achieved (without corrections) 2.8 mm and after corrections 0.55 mm; in case of Trimble M3 is nominal standard deviation 3 mm, achieved (without corrections) 1.1 mm and after corrections 0.58 mm; and finally in case of Trimble S6 is nominal standard deviation 1 mm, achieved (without corrections) 1.2 mm and after corrections 0.51 mm. Proposed procedure of the calibration and correction is in our opinion very suitable for increasing of the accuracy of the electronic distance measurement and allows the use of the common surveying instrument to achieve uncommonly high precision.

  13. Which Propensity Score Method Best Reduces Confounder Imbalance? An Example From a Retrospective Evaluation of a Childhood Obesity Intervention.

    PubMed

    Schroeder, Krista; Jia, Haomiao; Smaldone, Arlene

    Propensity score (PS) methods are increasingly being employed by researchers to reduce bias arising from confounder imbalance when using observational data to examine intervention effects. The purpose of this study was to examine PS theory and methodology and compare application of three PS methods (matching, stratification, weighting) to determine which best improves confounder balance. Baseline characteristics of a sample of 20,518 school-aged children with severe obesity (of whom 1,054 received an obesity intervention) were assessed prior to PS application. Three PS methods were then applied to the data to determine which showed the greatest improvement in confounder balance between the intervention and control group. The effect of each PS method on the outcome variable-body mass index percentile change at one year-was also examined. SAS 9.4 and Comprehensive Meta-analysis statistical software were used for analyses. Prior to PS adjustment, the intervention and control groups differed significantly on seven of 11 potential confounders. PS matching removed all differences. PS stratification and weighting both removed one difference but created two new differences. Sensitivity analyses did not change these results. Body mass index percentile at 1 year decreased in both groups. The size of the decrease was smaller in the intervention group, and the estimate of the decrease varied by PS method. Selection of a PS method should be guided by insight from statistical theory and simulation experiments, in addition to observed improvement in confounder balance. For this data set, PS matching worked best to correct confounder imbalance. Because each method varied in correcting confounder imbalance, we recommend that multiple PS methods be compared for ability to improve confounder balance before implementation in evaluating treatment effects in observational data.

  14. Single-baseline RTK GNSS Positioning for Hydrographic Surveying

    NASA Astrophysics Data System (ADS)

    Metin Alkan, Reha; Murat Ozulu, I.; Ilçi, Veli; Kahveci, Muzaffer

    2015-04-01

    Positioning with GNSS technique can be carried out in two ways, absolute and relative. It has been possible to reach a few meters absolute point positioning accuracies in real time after disabling SA permanently in May 2000. Today, accuracies obtainable from absolute point positioning using code observations are not sufficient for most surveying applications. Thus to meet higher accuracy requirements, differential methods using single or dual frequency geodetic-grade GNSS receivers that measure carrier phase have to be used. However, this method requires time-cost field and office works and if the measurement is not carried out with conventional RTK method, user needs a GNSS data processing software to estimate the coordinates. If RTK is used, at least two or more GNSS receivers are required, one as a reference and the other as a rover. Moreover, the distance between the receivers must not exceed 15-20 km in order to be able to rapidly and reliably resolve the carrier phase ambiguities. On the other hand, based on the innovations and improvements in satellite geodesy and GNSS modernization studies occurred within the last decade, many new positioning methods and new approaches have been developed. One of them is Network-RTK (or commonly known as CORS) and the other is Single-baseline RTK. These methods are widely used for many surveying applications in many countries. The user of the system can obtain his/her position within a few cm level of accuracy in real-time with only a single GNSS receiver that has Network RTK (CORS) capability. When compared with the conventional differential and RTK methods, this technique has several significant advantages as it is easy to use and it produces accurate, cost-effective and rapid solutions. In Turkey, establishment of a multi-base RTK network was completed and opened for civilian use in 2009. This network is called CORS-TR and consists of 146 reference stations having about 80-100 km interstation distances. It is possible for a user to determine his/her position with a few cm accuracy in real time in Turkey. Besides, there are some province municipalities in Turkey which have established their own local CORS networks such as Istanbul (with 9 reference stations) and Ankara (with 10 reference stations). There is also a local RTK base station which disseminates real time position corrections for surveyors in Çorum province and is operated by Çorum Municipality. This is the first step of establishing a complete local CORS network in Çorum (the municipality has plans to increase this number and establish a CORS network within a few years). At the time of this study, unfortunately, national CORS-TR stations in Çorum Province were under maintenance and thus we could not receive corrections from our national CORS network. Instead, Çorum Province's local RTK reference station's corrections were used during the study. The main purpose of this study is to investigate the accuracy performance of the Single-baseline RTK GNSS system operated by Çorum Municipality in marine environment. For this purpose, a kinematic test measurement was carried out at Obruk Dam, Çorum, Turkey. During the test measurement, a small vessel equipped with a dual-frequency geodetic-grade GNSS receiver, Spectra Precision ProMark 500, was used. The coordinates of the vessel were obtained from the Single-baseline RTK system in ITRF datum in real-time with fix solutions. At the same time, the raw kinematic GNSS data were also recorded to the receiver in order to estimate the known coordinates of the vessel with post-processed differential kinematic technique. In this way, GPS data were collected under the same conditions, which allowed precise assessment of the used system. The measurements were carried out along the survey profiles for about 1 hour. During the kinematic test, another receiver was set up on a geodetic point at the shore and data were collected in static mode to calculate the coordinates of the vessel for each epoch. As mentioned above, the vessel coordinates were estimated very accurately by using data collected on shore and vessel by using differential GNSS technique. The Single-baseline RTK-derived coordinates were compared with those obtained from the post-processing of the GNSS data for each epoch. Computed differences show that the coordinates agree with the relative solutions at 7 cm and below in position. Some marine applications like precise hydrographic surveying, monitoring silt accretion and erosion in rivers, lakes, estuaries, coastal waters and harbor areas; marine geodynamics; automatic docking; dredging; construction work; attitude control of ships, buoys and floating platforms, require high accuracy better than 0.1 m in position and height. Results obtained from this application show that Single-baseline RTK and/or CORS systems can reliably be utilized for the above mentioned marine applications and some others especially for positioning as a strong alternative to the conventional differential methods.

  15. Spectroscopic characterization of enzymatic flax retting: Factor analysis of FT-IR and FT-Raman data

    NASA Astrophysics Data System (ADS)

    Archibald, D. D.; Henrikssen, G.; Akin, D. E.; Barton, F. E.

    1998-06-01

    Flax retting is a chemical, microbial or enzymatic process which releases the bast fibers from the stem matrix so they can be suitable for mechanical processing before spinning into linen yarn. This study aims to determine the vibrational spectral features and sampling methods which can be used to evaluate the retting process. Flax stems were retted on a small scale using an enzyme mixture known to yield good retted flax. Processed stems were harvested at various time points in the process and the retting was evaluated by conventional methods including weight loss, color difference and Fried's test, a visual ranking of how the stems disintegrate in hot water. Spectroscopic measurements were performed on either whole stems or powders of the fibers that were mechanically extracted from the stems. Selected regions of spectra were baseline and amplitude corrected using a variant of the multiplicative signal correction method. Principal component regression and partial least-squares regression with full cross-validation were used to determine the spectral features and rate of spectral transformation by regressing the spectra against the retting time in hours. FT-Raman of fiber powders and FT-IR reflectance of whole stems were the simplest and most precise methods for monitoring the retting transformation. Raman tracks the retting by measuring the decrease in aromatic signal and subtle changes in the C-H stretching vibrations. The IR method uses complex spectral features in the fingerprint and carbonyl region, many of which are due to polysaccharide components. Both spectral techniques monitor the retting process with greater precision than the reference method.

  16. Treatment of word-finding deficits in fluent aphasia through the manipulation of spatial attention: Preliminary findings

    PubMed Central

    Dotson, Vonetta M.; Singletary, Floris; Fuller, Renee; Koehler, Shirley; Moore, Anna Bacon; Gonzalez Rothi, Leslie J.; Crosson, Bruce

    2010-01-01

    Background Attention, the processing of one source of information to the exclusion of others, is important for most cognitive processes, including language. Evidence suggests not only that dysfunctional attention mechanisms contribute to language deficits after stroke, but also that orienting attention to a patient's ipsilesional hemispace recruits attention mechanisms in the intact hemisphere and improves language functions in some persons with aphasia. Aims The aim of the current research was to offer proof of concept for the strategy of improving picture-naming performance in fluent aphasia by moving stimuli into the left hemispace. It was hypothesised that repeated orientation of attention to the ipsilesional hemispace during picture naming would lead to improved naming accuracy for participants with fluent aphasia. Methods & Procedures Three participants with stable fluent aphasia received daily treatment sessions that consisted of naming simple line drawings presented 45 degrees to the left of body midline on a computer monitor. Naming probes were administered before initiation of the treatment protocol to establish a baseline, and before each treatment session to measure change during treatment. The C statistic was used to establish the stability of baseline performance and to determine whether the slope of the treatment phases differed significantly from the slope of the baseline. Outcomes & Results Two of the three participants showed significant improvement over baseline performance in the percent correct of naming probes. One participant showed no improvement over baseline accuracy. Conclusions Results suggest that engaging right-hemisphere attention mechanisms may improve naming accuracy in some people with fluent aphasia. Findings justify further investigation of this treatment in a larger controlled study. PMID:22131638

  17. Supersonic Aftbody Closure Wind-Tunnel Testing, Data Analysis, and Computational Results

    NASA Technical Reports Server (NTRS)

    Allen, Jerry; Martin, Grant; Kubiatko, Paul

    1999-01-01

    This paper reports on the model, test, and results from the Langley Supersonic Aftbody Closure wind tunnel test. This project is an experimental evaluation of the 1.5% Technology Concept Aircraft (TCA) aftbody closure model (Model 23) in the Langley Unitary Plan Wind Tunnel. The baseline TCA design is the result of a multidisciplinary, multipoint optimization process and was developed using linear design and analysis methods, supplemented with Euler and Navier-Stokes numerical methods. After a thorough design review, it was decided to use an upswept blade attached to the forebody as the mounting system. Structural concerns dictated that a wingtip support system would not be feasible. Only the aftbody part of the model is metric. The metric break was chosen to be at the fuselage station where prior aft-sting supported models had been truncated. Model 23 is thus a modified version of Model 20. The wing strongback, flap parts, and nacelles from Model 20 were used, whereas new aftbodies, a common forebody, and some new tails were fabricated. In summary, significant differences in longitudinal and direction stability and control characteristics between the ABF and ABB aftbody geometries were measured. Correcting the experimental data obtained for the TCA configuration with the flared aftbody to the representative of the baseline TCA closed aftbody will result in a significant reduction in longitudinal stability, a moderate reduction in stabilizer effectiveness and directional stability, and a moderate to significant reduction in rudder effectiveness. These reductions in the stability and control effectiveness levels of the baseline TCA closed aftbody are attributed to the reduction in carry-over area.

  18. Sibsonian and non-Sibsonian natural neighbour interpolation of the total electron content value

    NASA Astrophysics Data System (ADS)

    Kotulak, Kacper; Froń, Adam; Krankowski, Andrzej; Pulido, German Olivares; Henrandez-Pajares, Manuel

    2017-03-01

    In radioastronomy the interferometric measurement between radiotelescopes located relatively close to each other helps removing ionospheric effects. Unfortunately, in case of networks such as LOw Frequency ARray (LOFAR), due to long baselines (currently up to 1500 km), interferometric methods fail to provide sufficiently accurate ionosphere delay corrections. Practically it means that systems such as LOFAR need external ionosphere information, coming from Global or Regional Ionospheric Maps (GIMs or RIMs, respectively). Thanks to the technology based on Global Navigation Satellite Systems (GNSS), the scientific community is provided with ionosphere sounding virtually worldwide. In this paper we compare several interpolation methods for RIMs computation based on scattered Vertical Total Electron Content measurements located on one thin ionospheric layer (Ionospheric Pierce Points—IPPs). The results of this work show that methods that take into account the topology of the data distribution (e.g., natural neighbour interpolation) perform better than those based on geometric computation only (e.g., distance-weighted methods).

  19. Pose determination of a blade implant in three dimensions from a single two-dimensional radiograph.

    PubMed

    Toti, Paolo; Barone, Antonio; Marconcini, Simone; Menchini-Fabris, Giovanni Battista; Martuscelli, Ranieri; Covani, Ugo

    2018-05-01

    The aim of the study was to introduce a mathematical method to estimate the correct pose of a blade by evaluating the radiographic features obtained from a single two-dimensional image. Blade-form implant bed preparation was performed using the piezosurgery device, and placement was attained with the use of magnetic mallet. The pose determination of the blade was described by means of three consecutive rotations defined by three angles of orientation (triplet φ, θ and ψ). Retrospective analysis on periapical radiographs was performed. This method was used to compare implant (axial length along the marker, i.e. the implant structure) vs angular correction factor (a trigonometric function of the triplet). The accuracy of the method was tested by generating two-dimensional radiographic simulations of the blades, which were then compared with the images of the implants as appearing on the real radiographs. Two patients had to be excluded from further evaluation because the values of the estimated pose angles showed a too-wide range to be effective for a good standardization of serial radiographs: intrapatient range from baseline to 1-year survey was > of a threshold determined by the clinicians (30°). The linear dependence between implant (CF°) and angular correction factor (CF^) was estimated by a robust linear regression, yielding the following coefficients: slope, 0.908; intercept, -0.092; and coefficient of determination, 0.924. The absolute error in accuracy was -0.29 ± 4.35, 0.23 ± 3.81 and 0.64 ± 1.18°, respectively, for the angles φ, θ and ψ. The present theoretical and experimental study established the possibility of determining, a posteriori, a unique triplet of angles (φ, θ and ψ) which described the pose of a blade upon a single two-dimensional radiograph, and of suggesting a method to detect cases in which the standardized geometric projection failed. The angular correction of the bone level yielded results very close to those obtained with an internal marker related to the implant length.

  20. The sodium glucose cotransporter 2 inhibitor empagliflozin does not prolong QT interval in a thorough QT (TQT) study

    PubMed Central

    2013-01-01

    Background Empagliflozin is a potent, selective sodium glucose cotransporter 2 (SGLT2) inhibitor in development as an oral antidiabetic treatment. This QT interval study assessed potential effects of empagliflozin on ventricular repolarisation and other electrocardiogram (ECG) parameters. Methods A randomised, placebo-controlled, single-dose, double-blind, five-period crossover study incorporating a novel double-placebo period design to reduce sample size, while maintaining full statistical power. Treatments: single empagliflozin doses of 25 mg (therapeutic) and 200 mg (supratherapeutic), matching placebo and open-label moxifloxacin 400 mg (positive control). Triplicate 12-lead ECGs of 10 second duration were recorded at baseline and during the first 24 hours after dosing. The primary endpoint was mean change from baseline (MCfB) in the population heart rate-corrected QT interval (QTcN) between 1–4 hours after dosing. Results Thirty volunteers (16 male, 14 female, mean [range] age: 34.5 [18–52] years) were randomised. The placebo-corrected MCfB in QTcN 1–4 hours after dosing was 0.6 (90% CI: -0.7, 1.9) ms and -0.2 (-1.4, 0.9) ms for empagliflozin 25 mg and 200 mg, respectively, below the ICH E14 defined threshold of regulatory concern 10 ms. Assay sensitivity was confirmed by a placebo-corrected MCfB in QTcN 2–4 hours post-dose of 12.4 (10.7, 14.1) ms with moxifloxacin 400 mg. Empagliflozin tolerability was good for all volunteers; 23.3% experienced adverse events (AEs) with empagliflozin and 27.6% with placebo. The most frequent AE was nasopharyngitis. Conclusions/interpretation Single doses of empagliflozin 25 mg and 200 mg were not associated with QTcN prolongation and were well tolerated in healthy volunteers. Trial registration ClinicalTrials.gov: NCT01195675 PMID:23617452

  1. The DPP-4 inhibitor linagliptin does not prolong the QT interval at therapeutic and supratherapeutic doses

    PubMed Central

    Ring, Arne; Port, Andreas; Graefe-Mody, E Ulrike; Revollo, Ivette; Iovino, Mario; Dugi, Klaus A

    2011-01-01

    AIM To evaluate the potential effects of therapeutic and supratherapeutic doses of linagliptin (BI 1356) on the QT/QTc interval in healthy subjects. METHODS The study was a randomized, double-blind, placebo-controlled, four-period crossover study using single oral doses of linagliptin (5 mg and 100 mg), moxifloxacin (400 mg) and placebo. Electrocardiogram (ECG) profiles using triplicates of 12-lead 10-s ECGs were digitally recorded pre-dose and after drug administration. The mean change from baseline (MCfB) of the individually heart rate corrected QT interval (QTcI) between 1 and 4 h postdrug administration was the primary end point. Blood samples to measure plasma concentrations of linagliptin and its main metabolite were also obtained. RESULTS Forty-four Caucasian subjects (26 male) entered the study and 43 subjects completed the study as planned in the protocol. Linagliptin was not associated with an increase in the baseline-adjusted mean QTcI, at any time point. The placebo-corrected MCfB of QTcI was −1.1 (90% CI −2.7, 0.5) ms and −2.5 (–4.1, –0.9) ms for linagliptin 5 mg and 100 mg, respectively, thus within the non-inferiority margin of 10 ms according to ICH E14. Linagliptin was well tolerated; the assessment of ECGs and other safety parameters gave no clinically relevant findings at either dose tested. Maximum plasma concentrations after administration of 100-mg linagliptin were ∼24-fold higher than those observed previously for chronic treatment with the therapeutic 5-mg dose. Assay sensitivity was confirmed by a placebo-corrected MCfB of QTcI with moxifloxacin of 6.9 (90% CI 5.4, 8.5) ms. CONCLUSIONS Therapeutic and significantly supratherapeutic exposure to linagliptin is not associated with QT interval prolongation. PMID:21306414

  2. A guide to performing basic manifest refractometry.

    PubMed

    Garber, N

    2000-01-01

    Refractometry provides the ophthalmologist with the prescription that has the most plus power with the best vision. This eliminates the need for the patient accommodating to achieve clear vision at distance. Flowcharts, of the refractometry process, help the refractionist use standard procedures to accurately arrive at the correct baseline prescription for the patient's refractive state. By using the patient's history of subjective complaints, past refractive corrections, and present visual needs, the ophthalmologist then can prescribe the final prescription.

  3. Repeated readings and science: Fluency with expository passages

    NASA Astrophysics Data System (ADS)

    Kostewicz, Douglas E.

    The current study investigated the effects of repeated readings to a fluency criterion (RRFC) for seven students with disabilities using science text. The study employed a single subject design, specifically, two multiple probe multiple baselines across subjects, to evaluate the effects of the RRFC intervention. Results indicated that students met criterion (200 or more correct words per minute with 2 or fewer errors) on four consecutive passages. A majority of students displayed accelerations to correct words per minute and decelerations to incorrect words per minute on successive initial, intervention readings suggesting reading transfer. Students' reading scores during posttest and maintenance out performed pre-test and baseline readings provided additional measures of reading transfer. For a relationship to comprehension, students scored higher on oral retell measures after meeting criterion as compared to initial readings. Overall, the research findings suggested that the RRFC intervention improves science reading fluency for students with disabilities, and may also indirectly benefit comprehension.

  4. Selection of neural network structure for system error correction of electro-optical tracker system with horizontal gimbal

    NASA Astrophysics Data System (ADS)

    Liu, Xing-fa; Cen, Ming

    2007-12-01

    Neural Network system error correction method is more precise than lest square system error correction method and spheric harmonics function system error correction method. The accuracy of neural network system error correction method is mainly related to the frame of Neural Network. Analysis and simulation prove that both BP neural network system error correction method and RBF neural network system error correction method have high correction accuracy; it is better to use RBF Network system error correction method than BP Network system error correction method for little studying stylebook considering training rate and neural network scale.

  5. Rapid Structured Volume Grid Smoothing and Adaption Technique

    NASA Technical Reports Server (NTRS)

    Alter, Stephen J.

    2006-01-01

    A rapid, structured volume grid smoothing and adaption technique, based on signal processing methods, was developed and applied to the Shuttle Orbiter at hypervelocity flight conditions in support of the Columbia Accident Investigation. Because of the fast pace of the investigation, computational aerothermodynamicists, applying hypersonic viscous flow solving computational fluid dynamic (CFD) codes, refined and enhanced a grid for an undamaged baseline vehicle to assess a variety of damage scenarios. Of the many methods available to modify a structured grid, most are time-consuming and require significant user interaction. By casting the grid data into different coordinate systems, specifically two computational coordinates with arclength as the third coordinate, signal processing methods are used for filtering the data [Taubin, CG v/29 1995]. Using a reverse transformation, the processed data are used to smooth the Cartesian coordinates of the structured grids. By coupling the signal processing method with existing grid operations within the Volume Grid Manipulator tool, problems related to grid smoothing are solved efficiently and with minimal user interaction. Examples of these smoothing operations are illustrated for reductions in grid stretching and volume grid adaptation. In each of these examples, other techniques existed at the time of the Columbia accident, but the incorporation of signal processing techniques reduced the time to perform the corrections by nearly 60%. This reduction in time to perform the corrections therefore enabled the assessment of approximately twice the number of damage scenarios than previously possible during the allocated investigation time.

  6. Rapid Structured Volume Grid Smoothing and Adaption Technique

    NASA Technical Reports Server (NTRS)

    Alter, Stephen J.

    2004-01-01

    A rapid, structured volume grid smoothing and adaption technique, based on signal processing methods, was developed and applied to the Shuttle Orbiter at hypervelocity flight conditions in support of the Columbia Accident Investigation. Because of the fast pace of the investigation, computational aerothermodynamicists, applying hypersonic viscous flow solving computational fluid dynamic (CFD) codes, refined and enhanced a grid for an undamaged baseline vehicle to assess a variety of damage scenarios. Of the many methods available to modify a structured grid, most are time-consuming and require significant user interaction. By casting the grid data into different coordinate systems, specifically two computational coordinates with arclength as the third coordinate, signal processing methods are used for filtering the data [Taubin, CG v/29 1995]. Using a reverse transformation, the processed data are used to smooth the Cartesian coordinates of the structured grids. By coupling the signal processing method with existing grid operations within the Volume Grid Manipulator tool, problems related to grid smoothing are solved efficiently and with minimal user interaction. Examples of these smoothing operations are illustrated for reduction in grid stretching and volume grid adaptation. In each of these examples, other techniques existed at the time of the Columbia accident, but the incorporation of signal processing techniques reduced the time to perform the corrections by nearly 60%. This reduction in time to perform the corrections therefore enabled the assessment of approximately twice the number of damage scenarios than previously possible during the allocated investigation time.

  7. Post - SM4 Flux Calibration of the STIS Echelle Modes

    NASA Astrophysics Data System (ADS)

    Bostroem, Azalee; Aloisi, A.; Bohlin, R. C.; Proffitt, C. R.; Osten, R. A.; Lennon, D.

    2010-07-01

    Like all STIS spectroscopic modes, STIS echelle modes show a wavelength dependent decline in detector sensitivity with time. The echelle sensitivity is further affected by a time-dependent shift in the blaze function. To better correct the effects of the echelle sensitivity loss and the blaze function changes, we derive new baselines for echelle sensitivities from post-HST Servicing Mission 4 observations of the standard star G191-B2B. We present how these baseline sensitivities compare to pre-failure trends.

  8. Stroke education program of act FAST for junior high school students and their parents.

    PubMed

    Amano, Tatsuo; Yokota, Chiaki; Sakamoto, Yuki; Shigehatake, Yuya; Inoue, Yasuteru; Ishigami, Akiko; Hagihara, Takaaki; Tomii, Yasuhiro; Miyashita, Fumio; Toyoda, Kazunori; Minematsu, Kazuo

    2014-01-01

    We produced a stroke education program using the FAST (facial droop, arm weakness, speech disturbance, time to call an ambulance) mnemonic. The aim of this study is to examine efficacy of our education program for junior high school students and their parents. One hundred ninety students of 3 junior high schools (aged 12-13 years) and their parents were enrolled. Students received a 45-minute lesson of stroke enlightenment using the FAST mnemonic. Enlightenment items, such as a magnet poster, were distributed. Parents were educated indirectly from their child. Surveys of stroke knowledge were examined at baseline, immediately after the lesson, and at 3 months after the lesson. For the students, correct answers at 3 months were significantly higher than those at baseline in questions of facial palsy (98% versus 33%), speech disturbance (98% versus 54%), numbness on one side (64% versus 42%), weakness on one side (80% versus 51%), calling an ambulance (88% versus 60%), alcohol drinking (85% versus 65%), smoking (70% versus 43%), dyslipidemia (58% versus 46%), hyperglycemia (59% versus 48%), and obesity (47% versus 23%). At 3 months, the parents answered more correctly questions of facial palsy (93% versus 66%), calling an ambulance (95% versus 88%), and alcohol drinking (65% versus 51%) than at baseline. At 3 months, 96% of students and 78% of parents answered the FAST mnemonic correctly. Our stroke education program improved stroke knowledge, especially the FAST message, for junior high school students and their parents. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  9. SU-E-J-254: Evaluating the Role of Mid-Treatment and Post-Treatment FDG-PET/CT in Predicting Progression-Free Survival and Distant Metastasis of Anal Cancer Patients Treated with Chemoradiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, H; Wang, J; Chuong, M

    2015-06-15

    Purpose: To evaluate the role of mid-treatment and post-treatment FDG-PET/CT in predicting progression-free survival (PFS) and distant metastasis (DM) of anal cancer patients treated with chemoradiotherapy (CRT). Methods: 17 anal cancer patients treated with CRT were retrospectively studied. The median prescription dose was 56 Gy (range, 50–62.5 Gy). All patients underwent FDG-PET/CT scans before and after CRT. 16 of the 17 patients had an additional FDG-PET/CT image at 3–5 weeks into the treatment (denoted as mid-treatment FDG-PET/CT). 750 features were extracted from these three sets of scans, which included both traditional PET/CT measures (SUVmax, SUVpeak, tumor diameters, etc.) and spatialtemporalmore » PET/CT features (comprehensively quantify a tumor’s FDG uptake intensity and distribution, spatial variation (texture), geometric property and their temporal changes relative to baseline). 26 clinical parameters (age, gender, TNM stage, histology, GTV dose, etc.) were also analyzed. Advanced analytics including methods to select an optimal set of predictors and a model selection engine, which identifies the most accurate machine learning algorithm for predictive analysis was developed. Results: Comparing baseline + mid-treatment PET/CT set to baseline + posttreatment PET/CT set, 14 predictors were selected from each feature group. Same three clinical parameters (tumor size, T stage and whether 5-FU was held during any cycle of chemotherapy) and two traditional measures (pre- CRT SUVmin and SUVmedian) were selected by both predictor groups. Different mix of spatial-temporal PET/CT features was selected. Using the 14 predictors and Naive Bayes, mid-treatment PET/CT set achieved 87.5% accuracy (2 PFS patients misclassified, all local recurrence and DM patients correctly classified). Post-treatment PET/CT set achieved 94.0% accuracy (all PFS and DM patients correctly predicted, 1 local recurrence patient misclassified) with logistic regression, neural network or support vector machine model. Conclusion: Applying radiomics approach to either midtreatment or post-treatment PET/CT could achieve high accuracy in predicting anal cancer treatment outcomes. This work was supported in part by the National Cancer Institute Grant R01CA172638.« less

  10. Permutation Tests of Hierarchical Cluster Analyses of Carrion Communities and Their Potential Use in Forensic Entomology.

    PubMed

    van der Ham, Joris L

    2016-05-19

    Forensic entomologists can use carrion communities' ecological succession data to estimate the postmortem interval (PMI). Permutation tests of hierarchical cluster analyses of these data provide a conceptual method to estimate part of the PMI, the post-colonization interval (post-CI). This multivariate approach produces a baseline of statistically distinct clusters that reflect changes in the carrion community composition during the decomposition process. Carrion community samples of unknown post-CIs are compared with these baseline clusters to estimate the post-CI. In this short communication, I use data from previously published studies to demonstrate the conceptual feasibility of this multivariate approach. Analyses of these data produce series of significantly distinct clusters, which represent carrion communities during 1- to 20-day periods of the decomposition process. For 33 carrion community samples, collected over an 11-day period, this approach correctly estimated the post-CI within an average range of 3.1 days. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. A Simple Evaluation Tool (ET-CET) Indicates Increase of Diagnostic Skills From Small Bowel Capsule Endoscopy Training Courses: A Prospective Observational European Multicenter Study.

    PubMed

    Albert, J G; Humbla, O; McAlindon, M E; Davison, C; Seitz, U; Fraser, C; Hagenmüller, F; Noetzel, E; Spada, C; Riccioni, M E; Barnert, J; Filmann, N; Keuchel, M

    2015-10-01

    Small bowel capsule endoscopy (SBCE) has become a first line diagnostic tool. Several training courses with a similar format have been established in Europe; however, data on learning curve and training in SBCE remain sparse.Between 2008 and 2011, different basic SBCE training courses were organized internationally in UK (n = 2), Italy (n = 2), Germany (n = 2), Finland (n = 1), and nationally in Germany (n = 10), applying similar 8-hour curricula with 50% lectures and 50% hands-on training. The Given PillCam System was used in 12 courses, the Olympus EndoCapsule system in 5, respectively. A simple evaluation tool for capsule endoscopy training (ET-CET) was developed using 10 short SBCE videos including relevant lesions and normal or irrelevant findings. For each video, delegates were required to record a diagnosis (achievable total score from 0 to 10) and the clinical relevance (achievable total score 0 to 10). ET-CET was performed at baseline before the course and repeated, with videos in altered order, after the course.Two hundred ninety-four delegates (79.3% physicians, 16.3% nurses, 4.4% others) were included for baseline analysis, 268 completed the final evaluation. Forty percent had no previous experience in SBCE, 33% had performed 10 or less procedures. Median scores for correct diagnosis improved from 4.0 (IQR 3) to 7.0 (IQR 3) during the courses (P < 0.001, Wilcoxon), and for correct classification of relevance of the lesions from 5.0 (IQR 3) to 7.0 (IQR 3) (P < 0.001), respectively. Improvement was not dependent on experience, profession, SBCE system, or course setting. Previous experience in SBCE was associated with higher baseline scores for correct diagnosis (P < 0.001; Kruskal-Wallis). Additionally, independent nonparametric partial correlation with experience in gastroscopy (rho 0.33) and colonoscopy (rho 0.27) was observed (P < 0.001).A simple ET-CET demonstrated significant improvement of diagnostic skills on completion of formal basic SBCE courses with hands-on training, regardless of preexisting experience, profession, and course setting. Baseline scores for correct diagnoses show a plateau after interpretation of 25 SBCE before courses, supporting this number as a compromise for credentialing. Experience in flexible endoscopy may be useful before attending an SBCE course.

  12. Developing school-pharmacist partnerships to enhance correct medication use and pain medication literacy in Taiwan.

    PubMed

    Chang, Fong-Ching; Chi, Hsueh-Yun; Huang, Li-Jung; Lee, Chun-Hsien; Yang, Jyun-Long; Yeh, Ming-Kung

    2015-01-01

    To evaluate the effectiveness of the health promoting school (HPS)-community pharmacist partnership program that promotes students' correct medication use and enhances pain medication literacy in Taiwan. Pre- and post-studies and intervention/comparison group comparisons. Primary and middle schools, along with their communities, in Taiwan. In 2013, baseline and follow-up self-administered, online surveys were received from 5,373 students enrolled in intervention primary and middle schools and from 4,643 students enrolled in comparison primary and middle schools. The level of medication literacy, including correct medication use knowledge, self-efficacy, and skills. The development and implementation of the HPS-community pharmacist partnership program in primary and middle schools significantly enhanced students' knowledge, self-efficacy, and skills in correct medication use and pain medication literacy (P <0.001). The HPS-community pharmacist partnership had a positive impact on enhancing correct medication use and pain medication literacy in Taiwan.

  13. Solving matrix effects exploiting the second-order advantage in the resolution and determination of eight tetracycline antibiotics in effluent wastewater by modelling liquid chromatography data with multivariate curve resolution-alternating least squares and unfolded-partial least squares followed by residual bilinearization algorithms II. Prediction and figures of merit.

    PubMed

    García, M D Gil; Culzoni, M J; De Zan, M M; Valverde, R Santiago; Galera, M Martínez; Goicoechea, H C

    2008-02-01

    A new powerful algorithm (unfolded-partial least squares followed by residual bilinearization (U-PLS/RBL)) was applied for first time on second-order liquid chromatography with diode array detection (LC-DAD) data and compared with a well-known established method (multivariate curve resolution-alternating least squares (MCR-ALS)) for the simultaneous determination of eight tetracyclines (tetracycline, oxytetracycline, meclocycline, minocycline, metacycline, chlortetracycline, demeclocycline and doxycycline) in wastewaters. Tetracyclines were pre-concentrated using Oasis Max C18 cartridges and then separated on a Thermo Aquasil C18 (150 mm x 4.6mm, 5 microm) column. The whole method was validated using Milli-Q water samples and both univariate and multivariate analytical figures of merit were obtained. Additionally, two data pre-treatment were applied (baseline correction and piecewise direct standardization), which allowed to correct the effect of breakthrough and to reduce the total interferences retained after pre-concentration of wastewaters. The results showed that the eight tetracycline antibiotics can be successfully determined in wastewaters, the drawbacks due to matrix interferences being adequately handled and overcome by using U-PSL/RBL.

  14. Mathematical modeling of serum 13C-retinol in captive rhesus monkeys provides new insights on hypervitaminosis A.

    PubMed

    Escaron, Anne L; Green, Michael H; Howe, Julie A; Tanumihardjo, Sherry A

    2009-10-01

    Hypervitaminosis A is increasingly a public health concern, and thus noninvasive quantitative methods merit exploration. In this study, we applied the (13)C-retinol isotope dilution test to a nonhuman primate model with excessive liver stores. After baseline serum chemistries, rhesus macaques (Macaca mulatta; n = 16) were administered 3.5 mumol (13)C(2)-retinyl acetate. Blood was drawn at baseline, 5 h, and 2, 4, 7, 14, 21, and 28 d following the dose. Liver biopsies were collected 7 d before and 2 d after dosing (n = 4) and at 7, 14, and 28 d (n = 4/time) after dosing. Serum and liver were analyzed by HPLC and GC-combustion-isotope ratio MS for retinol and its enrichment, respectively. Model-based compartmental analysis was applied to serum data. Lactate dehydrogenase was elevated in 50% of the monkeys. Total body reserves (TBR) of vitamin A (VA) were calculated at 28 d. Predicted TBR (3.52 +/- 2.01 mmol VA) represented measured liver stores (4.56 +/- 1.38 mmol VA; P = 0.124). Predicted liver VA concentrations (13.3 +/- 9.7 micromol/g) were similar to measured liver VA concentrations (16.4 +/- 5.3 micromol/g). The kinetic models predict that 27-52% of extravascular VA is exchanging with serum in hypervitaminotic A monkeys. The test correctly diagnosed hypervitaminosis A in all monkeys, i.e. 100% sensitivity. Stable isotope techniques have important public health potential for the classification of VA status, including hypervitaminosis, because no other technique besides invasive liver biopsies, correctly identifies excessive liver VA stores.

  15. Insulin Secretion Improves in Cystic Fibrosis Following Ivacaftor Correction of CFTR: A Small Pilot Study

    PubMed Central

    Bellin, Melena D.; Laguna, Theresa; Leschyshyn, Janice; Regelmann, Warren; Dunitz, Jordan; Billings, JoAnne; Moran, Antoinette

    2013-01-01

    Objective To determine whether the cystic fibrosis transmembrane conductance regulator (CFTR) is involved in human insulin secretion by assessing the metabolic impact of the new CFTR corrector, ivacaftor. Methods This open-label pilot study was conducted in CF patients with the G551D mutation given new prescriptions for ivacaftor. At baseline and 4 weeks after daily ivacaftor therapy, intravenous (IVGTT) and oral glucose (OGTT) tolerance tests were performed. Results Five patients age 6–52 were studied. After 1 month on ivacaftor, the insulin response to oral glucose improved by 66–178% in all subjects except one with long-standing diabetes. OGTT glucose levels were not lower in the two individuals with diabetes or the two with normal glucose tolerance (NGT), but the glucose tolerance category in the subject with impaired glucose tolerance (IGT) improved to NGT after treatment. In response to intravenous glucose, the only patient whose acute insulin secretion did not improve had newly diagnosed, untreated CFRD. The others improved by 51–346%. Acute insulin secretion was partially restored in two subjects with no measurable acute insulin response at baseline, including the one with IGT and the one with long-standing diabetes. Conclusions This small pilot study suggests there is a direct role of CFTR in human insulin secretion. Larger, long-term longitudinal studies are necessary to determine whether early initiation of CFTR correction, particularly in young children with CF who have not yet lost considerable beta-cell mass, will delay or prevent development of diabetes in this high risk population. PMID:23952705

  16. Interferometric detection of freeze-thaw displacements of Alaskan permafrost using ERS-1 data

    NASA Technical Reports Server (NTRS)

    Werner, Charles L.; Gabriel, Andrew K.

    1993-01-01

    The possibility of making large scale (50 km) measurements of motions of the earth's surface with high resolution (10 m) and very high accuracy (1 cm) from multipass SAR interferometry was established in 1989. Other experiments have confirmed the viability and usefulness of the method. Work is underway in various groups to measure displacements from volcanic activity, seismic events, glacier motion, and in the present study, freeze-thaw cycles in Alaskan permafrost. The ground is known to move significantly in these cycles, and provided that freezing does not cause image decorrelation, it should be possible to measure both ground swelling and subsidence. The authors have obtained data from multiple passes of ERS-1 over the Toolik Lake region of northern Alaska of suitable quality for interferometry. The data are processed into images, and single interferograms are formed in the usual manner. Phase unwrapping is performed, and the multipass baselines are estimated from the images using both orbit ephemerides and scene tie points. The phases are scaled by the baseline ratio, and a double-difference interferogram (DDI) is formed. It is found that there is a residual 'saddle-shape' phase error across the image, which is postulated to be caused by a small divergence (10(exp -2) deg.) in the orbits. A simulation of a DDI from divergent orbits confirms the shape and magnitude of the error. A two-dimensional least squares fit to the error is performed, which is used to correct the DDI. The final, corrected DDI shows significant phase (altitude) changes over the period of the observation.

  17. Examination of a Method to Determine the Reference Region for Calculating the Specific Binding Ratio in Dopamine Transporter Imaging.

    PubMed

    Watanabe, Ayumi; Inoue, Yusuke; Asano, Yuji; Kikuchi, Kei; Miyatake, Hiroki; Tokushige, Takanobu

    2017-01-01

    The specific binding ratio (SBR) was first reported by Tossici-Bolt et al. for quantitative indicators for dopamine transporter (DAT) imaging. It is defined as the ratio of the specific binding concentration of the striatum to the non-specific binding concentration of the whole brain other than the striatum. The non-specific binding concentration is calculated based on the region of interest (ROI), which is set 20 mm inside the outer contour, defined by a threshold technique. Tossici-Bolt et al. used a 50% threshold, but sometimes we couldn't define the ROI of non-specific binding concentration (reference region) and calculate SBR appropriately with a 50% threshold. Therefore, we sought a new method for determining the reference region when calculating SBR. We used data from 20 patients who had undergone DAT imaging in our hospital, to calculate the non-specific binding concentration by the following methods, the threshold to define a reference region was fixed at some specific values (the fixing method) and reference region was visually optimized by an examiner at every examination (the visual optimization method). First, we assessed the reference region of each method visually, and afterward, we quantitatively compared SBR calculated based on each method. In the visual assessment, the scores of the fixing method at 30% and visual optimization method were higher than the scores of the fixing method at other values, with or without scatter correction. In the quantitative assessment, the SBR obtained by visual optimization of the reference region, based on consensus of three radiological technologists, was used as a baseline (the standard method). The values of SBR showed good agreement between the standard method and both the fixing method at 30% and the visual optimization method, with or without scatter correction. Therefore, the fixing method at 30% and the visual optimization method were equally suitable for determining the reference region.

  18. The effectiveness of a community-based breast cancer education intervention in the New York State Capital Region.

    PubMed

    Zeinomar, Nur; Moslehi, Roxana

    2013-09-01

    We determined the effectiveness of a community-based breast cancer education intervention among understudied populations in the New York State (NYS) Capital Region by assessing and comparing baseline and post-education breast cancer knowledge. Participants included 417 students recruited from five colleges/universities and 67 women from four community group organizations. Baseline and post-education knowledge was assessed via self-administered mostly multiple-choice questionnaires. An open-ended question soliciting opinions about public health prevention strategies against breast cancer was included on college/university students' questionnaires. Effectiveness of education intervention was estimated through a paired t test. Stratified analysis was done using demographic and descriptive variables. Answers to the open-ended questions were analyzed qualitatively. The mean percentage of correct answers increased from 39.9% at baseline to 80.8% post-education (P < 0.0001) among college/university students and from 43.5% to 77.8% (P < 0.0001) among community group members. Effectiveness remained statistically significant in all stratified analyses with similarly high percentage of correct answers achieved post-education irrespective of knowledge level at baseline. Stratified analysis also revealed similar patterns of improvement in overall knowledge and narrowing of the gap in post-education knowledge. Primary prevention emerged as the dominant theme post-education in students' responses to the open-ended question, signifying the effectiveness of our education in raising awareness about modifiable risk factors and inspiring proactive thinking about public health prevention strategies. This community-based education intervention was effective in increasing breast cancer knowledge among demographically diverse groups with low levels of baseline knowledge in the NYS Capital Region. Our findings provide leads for future public health prevention strategies.

  19. First Year Wilkinson Microwave Anisotropy Probe(WMAP) Observations: Data Processing Methods and Systematic Errors Limits

    NASA Technical Reports Server (NTRS)

    Hinshaw, G.; Barnes, C.; Bennett, C. L.; Greason, M. R.; Halpern, M.; Hill, R. S.; Jarosik, N.; Kogut, A.; Limon, M.; Meyer, S. S.

    2003-01-01

    We describe the calibration and data processing methods used to generate full-sky maps of the cosmic microwave background (CMB) from the first year of Wilkinson Microwave Anisotropy Probe (WMAP) observations. Detailed limits on residual systematic errors are assigned based largely on analyses of the flight data supplemented, where necessary, with results from ground tests. The data are calibrated in flight using the dipole modulation of the CMB due to the observatory's motion around the Sun. This constitutes a full-beam calibration source. An iterative algorithm simultaneously fits the time-ordered data to obtain calibration parameters and pixelized sky map temperatures. The noise properties are determined by analyzing the time-ordered data with this sky signal estimate subtracted. Based on this, we apply a pre-whitening filter to the time-ordered data to remove a low level of l/f noise. We infer and correct for a small (approx. 1 %) transmission imbalance between the two sky inputs to each differential radiometer, and we subtract a small sidelobe correction from the 23 GHz (K band) map prior to further analysis. No other systematic error corrections are applied to the data. Calibration and baseline artifacts, including the response to environmental perturbations, are negligible. Systematic uncertainties are comparable to statistical uncertainties in the characterization of the beam response. Both are accounted for in the covariance matrix of the window function and are propagated to uncertainties in the final power spectrum. We characterize the combined upper limits to residual systematic uncertainties through the pixel covariance matrix.

  20. Quantitative, Comparable Coherent Anti-Stokes Raman Scattering (CARS) Spectroscopy: Correcting Errors in Phase Retrieval

    PubMed Central

    Camp, Charles H.; Lee, Young Jong; Cicerone, Marcus T.

    2017-01-01

    Coherent anti-Stokes Raman scattering (CARS) microspectroscopy has demonstrated significant potential for biological and materials imaging. To date, however, the primary mechanism of disseminating CARS spectroscopic information is through pseudocolor imagery, which explicitly neglects a vast majority of the hyperspectral data. Furthermore, current paradigms in CARS spectral processing do not lend themselves to quantitative sample-to-sample comparability. The primary limitation stems from the need to accurately measure the so-called nonresonant background (NRB) that is used to extract the chemically-sensitive Raman information from the raw spectra. Measurement of the NRB on a pixel-by-pixel basis is a nontrivial task; thus, reference NRB from glass or water are typically utilized, resulting in error between the actual and estimated amplitude and phase. In this manuscript, we present a new methodology for extracting the Raman spectral features that significantly suppresses these errors through phase detrending and scaling. Classic methods of error-correction, such as baseline detrending, are demonstrated to be inaccurate and to simply mask the underlying errors. The theoretical justification is presented by re-developing the theory of phase retrieval via the Kramers-Kronig relation, and we demonstrate that these results are also applicable to maximum entropy method-based phase retrieval. This new error-correction approach is experimentally applied to glycerol spectra and tissue images, demonstrating marked consistency between spectra obtained using different NRB estimates, and between spectra obtained on different instruments. Additionally, in order to facilitate implementation of these approaches, we have made many of the tools described herein available free for download. PMID:28819335

  1. Authentication of Organically and Conventionally Grown Basils by Gas Chromatography/Mass Spectrometry Chemical Profiles

    PubMed Central

    Wang, Zhengfang; Chen, Pei; Yu, Liangli; Harrington, Peter de B.

    2013-01-01

    Basil plants cultivated by organic and conventional farming practices were accurately classified by pattern recognition of gas chromatography/mass spectrometry (GC/MS) data. A novel extraction procedure was devised to extract characteristic compounds from ground basil powders. Two in-house fuzzy classifiers, i.e., the fuzzy rule-building expert system (FuRES) and the fuzzy optimal associative memory (FOAM) for the first time, were used to build classification models. Two crisp classifiers, i.e., soft independent modeling by class analogy (SIMCA) and the partial least-squares discriminant analysis (PLS-DA), were used as control methods. Prior to data processing, baseline correction and retention time alignment were performed. Classifiers were built with the two-way data sets, the total ion chromatogram representation of data sets, and the total mass spectrum representation of data sets, separately. Bootstrapped Latin partition (BLP) was used as an unbiased evaluation of the classifiers. By using two-way data sets, average classification rates with FuRES, FOAM, SIMCA, and PLS-DA were 100 ± 0%, 94.4 ± 0.4%, 93.3 ± 0.4%, and 100 ± 0%, respectively, for 100 independent evaluations. The established classifiers were used to classify a new validation set collected 2.5 months later with no parametric changes except that the training set and validation set were individually mean-centered. For the new two-way validation set, classification rates with FuRES, FOAM, SIMCA, and PLS-DA were 100%, 83%, 97%, and 100%, respectively. Thereby, the GC/MS analysis was demonstrated as a viable approach for organic basil authentication. It is the first time that a FOAM has been applied to classification. A novel baseline correction method was used also for the first time. The FuRES and the FOAM are demonstrated as powerful tools for modeling and classifying GC/MS data of complex samples and the data pretreatments are demonstrated to be useful to improve the performance of classifiers. PMID:23398171

  2. SU-E-T-91: Correction Method to Determine Surface Dose for OSL Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reynolds, T; Higgins, P

    Purpose: OSL detectors are commonly used in clinic due to their numerous advantages, such as linear response, negligible energy, angle and temperature dependence in clinical range, for verification of the doses beyond the dmax. Although, due to the bulky shielding envelope, this type of detectors fails to measure skin dose, which is an important assessment of patient ability to finish the treatment on time and possibility of acute side effects. This study aims to optimize the methodology of determination of skin dose for conventional accelerators and a flattening filter free Tomotherapy. Methods: Measurements were done for x-ray beams: 6 MVmore » (Varian Clinac 2300, 10×10 cm{sup 2} open field, SSD = 100 cm) and for 5.5 MV (Tomotherapy, 15×40 cm{sup 2} field, SAD = 85 cm). The detectors were placed at the surface of the solid water phantom and at the reference depth (dref=1.7cm (Varian 2300), dref =1.0 cm (Tomotherapy)). The measurements for OSLs were related to the externally exposed OSLs measurements, and further were corrected to surface dose using an extrapolation method indexed to the baseline Attix ion chamber measurements. A consistent use of the extrapolation method involved: 1) irradiation of three OSLs stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. Results: OSL measurements showed an overestimation of surface doses by the factor 2.31 for Varian 2300 and 2.65 for Tomotherapy. The relationships: SD{sup 2300} = 0.68 × M{sup 2300}-12.7 and SDτoμo = 0.73 × Mτoμo-13.1 were found to correct the single OSL measurements to surface doses in agreement with Attix measurements to within 0.1% for both machines. Conclusion: This work provides simple empirical relationships for surface dose measurements using single OSL detectors.« less

  3. Cardiac repolarization during fingolimod treatment in patients with relapsing-remitting multiple sclerosis.

    PubMed

    Laiho, Aapo; Laitinen, Tiina M; Hartikainen, Päivi; Hartikainen, Juha E K; Laitinen, Tomi P; Simula, Sakari

    2018-02-01

    Fingolimod is a sphingosine-1-phosphate receptor modulator for the treatment of relapsing-remitting multiple sclerosis (RRMS). Despite an established effect on heart rate, the effect of fingolimod on cardiac repolarization is not completely known. Twenty-seven patients with RRMS underwent 24-hr ambulatory ECG before fingolimod (baseline), at the day of fingolimod initiation (1D) and after three-month treatment (3M). The mean values of RR-interval as well as QT-interval corrected by Bazzet's (QTcBaz) and Fridericia's (QTcFri) formula were compared between baseline, 1D, and 3M over 24-hr period as well as at daytime and nighttime. QTcBaz over 24-hr was shorter at 1D (414 ± 20 ms, p  < .001) and at 3M (414 ± 20 ms, p  < .001) than at baseline (418 ± 20 ms). In contrast, QTcFri over 24-hr was longer at 1D (410 ± 19 ms, p  < .001) but similar at 3M (406 ± 19 ms, p  = .355) compared to baseline (407 ± 19 ms). Daytime QTcBaz was shorter at 1D ( p  < .001) and at 3M ( p  = .007), whereas daytime QTcFri was longer at 1D ( p  < .05) but similar at 3M ( p  = ns) compared to baseline. During the night, changes were observed neither in QTcBaz nor in QTcFri between baseline, 1D, and 3M. Changes in cardiac repolarization after fingolimod initiation were mild and occurred at daytime. Ambiguously, QTcBaz demonstrated shortening, whereas QTcFri showed prolongation in cardiac repolarization after fingolimod initiation. The formula applied for QT-interval correction needs to be taken carefully into account as evaluating pharmacovigilance issues related to fingolimod.

  4. Culturally Responsive Adolescent Pregnancy and Sexually Transmitted Infection Prevention Program for Middle School Students in Hawai‘i

    PubMed Central

    Barker, Linda Toms; Chan, Vincent; Eucogco, Jasmine

    2016-01-01

    Objectives. To evaluate the effectiveness of Pono Choices, a culturally responsive adolescent pregnancy and sexually transmitted infection (STI) prevention program targeting middle school youths in Hawai‘i. Methods. We conducted a cluster randomized controlled trial with the school as the unit of random assignment over 3 semesters between 2012 and 2013. The sample consisted of 36 middle schools and 2203 students. We administered student surveys to collect baseline outcomes, student demographic data, and outcomes at 12 months after baseline. Results. We found statistically significant effects for the knowledge assessment, which focused on basic understanding of adolescent pregnancy and STI prevention. The average percentage of correct responses was 73.6 for the treatment group and 60.4 for the control group (P < .001). We did not find statistically significant effects on behavioral outcomes (initiation of sexual activity or engagement in high-risk sexual behavior) or on other nonbehavioral outcomes (attitudes, skills, intentions). Conclusions. Pono Choices had a statistically significant impact on knowledge of adolescent pregnancy and STI prevention among middle school students at 12 months after baseline, though it did not lead to detectable changes in behavioral outcomes within the 1-year observation period. These results call for an exploration of longer-term outcomes to assess effects on knowledge retention and behavioral changes. PMID:27689477

  5. Altered cerebral blood flow and neurocognitive correlates in adolescent cannabis users

    PubMed Central

    Jacobus, Joanna; Goldenberg, Diane; Wierenga, Christina E.; Tolentino, Neil J.; Liu, Thomas T.

    2012-01-01

    Rationale The effects of adolescent marijuana use on the developing brain remain unclear, despite its prevalence. Arterial spin labeling (ASL) is a noninvasive imaging technique that characterizes neurovascular status and cerebral blood flow (CBF), potentially revealing contributors to neuropathological alterations. No studies to date have looked at CBF in adolescent marijuana users. Objectives This study examined CBF in adolescent marijuana users and matched healthy controls at baseline and after 4 weeks of monitored abstinence. Methods Heavy adolescent marijuana users (n=23, >200 lifetime marijuana use days) and demographically matched controls (n=23) with limited substance exposure underwent an ASL brain scan at an initial session and after 4 weeks of sequential urine toxicology to confirm abstinence. Results Marijuana users showed reduced CBF in four cortical regions including the left superior and middle temporal gyri, left insula, left and right medial frontal gyrus, and left supramarginal gyrus at baseline; users showed increased CBF in the right precuneus at baseline, as compared to controls (corrected p values<0.05). No between group differences were found at follow-up. Conclusions Marijuana use may influence CBF in otherwise healthy adolescents acutely; however, group differences were not observed after several weeks of abstinence. Neurovascular alterations may contribute to or underlie changes in brain activation, neuropsychological performance, and mood observed in young cannabis users with less than a month of abstinence. PMID:22395430

  6. A Continental Rifting Event in Tanzania Revealed by Envisat and ALOS InSAR Observations

    NASA Astrophysics Data System (ADS)

    Oyen, A. M.; Marinkovic, P. S.; Wauthier, C.; d'Oreye, N.; Hanssen, R. F.

    2008-11-01

    From July to September 2007 a series of moderate earthquakes struck the area South of the Gelai volcano, located on the Eastern branch of the East African Rift (North Tanzania). Most deformation patterns detected by InSAR in these period are very complex, impeding proper interpretation. To decrease the complexity of the models of the deformation, this study proposes two strategies of combining data from different tracks and sensors. In a first stage a method is proposed to correct unwrapping errors in C-band using the much more coherent L-band data. Furthermore, a modeling optimization method is explored, which aims at the decomposition of the deformation in smaller temporal baselines, by means of creating new, artificial interferograms and the use of models. Due to the higher coherence level and fewer phase cycles in L-band, the deformation interpretation is facilitated but model residual interpretation has become more difficult compared to C-band.

  7. Flutter suppression by active control and its benefits

    NASA Technical Reports Server (NTRS)

    Doggett, R. V., Jr.; Townsend, J. C.

    1976-01-01

    A general discussion of the airplane applications of active flutter suppression systems is presented with focus on supersonic cruise aircraft configurations. Topics addressed include a brief historical review; benefits, risks, and concerns; methods of application; and applicable configurations. Results are presented where the direct operating costs and performance benefits of an arrow wing supersonic cruise vehicle equipped with an active flutter suppression system are compared with corresponding costs and performance of the same baseline airplane where the flutter deficiency was corrected by passive methods (increases in structural stiffness). The design, synthesis, and conceptual mechanization of the active flutter suppression system are discussed. The results show that a substantial weight savings can be accomplished by using the active system. For the same payload and range, airplane direct operating costs are reduced by using the active system. The results also indicate that the weight savings translates into increased range or payload.

  8. Factors Associated with Correct and Consistent Insecticide Treated Curtain Use in Iquitos, Peru

    PubMed Central

    Scott, Thomas W.; Elder, John P.; Alexander, Neal; Halsey, Eric S.; McCall, Philip J.

    2016-01-01

    Dengue is an arthropod-borne virus of great public health importance, and control of its mosquito vectors is currently the only available method for prevention. Previous research has suggested that insecticide treated curtains (ITCs) can lower dengue vector infestations in houses. This observational study investigated individual and household-level socio-demographic factors associated with correct and consistent use of ITCs in Iquitos, Peru. A baseline knowledge, attitudes, and practices (KAP) survey was administered to 1,333 study participants, and ITCs were then distributed to 593 households as part of a cluster-randomized trial. Follow up KAP surveys and ITC-monitoring checklists were conducted at 9, 18, and 27 months post-ITC distribution. At 9 months post-distribution, almost 70% of ITCs were hanging properly (e.g. hanging fully extended or tied up), particularly those hung on walls compared to other locations. Proper ITC hanging dropped at 18 months to 45.7%. The odds of hanging ITCs correctly and consistently were significantly greater among those participants who were housewives, knew three or more correct symptoms of dengue and at least one correct treatment for dengue, knew a relative or close friend who had had dengue, had children sleeping under a mosquito net, or perceived a change in the amount of mosquitoes in the home. Additionally, the odds of recommending ITCs in the future were significantly greater among those who perceived a change in the amount of mosquitoes in the home (e.g. perceived the ITCs to be effective). Despite various challenges associated with the sustained effectiveness of the selected ITCs, almost half of the ITCs were still hanging at 18 months, suggesting a feasible vector control strategy for sustained community use. PMID:26967157

  9. Serial survey shows community intervention may contribute to increase in knowledge of Tuberculosis in 30 districts of India.

    PubMed

    Thapa, Badri; Prasad, Banuru Muralidhara; Chadha, Sarabjit S; Tonsing, Jamie

    2016-11-11

    Correct knowledge about Tuberculosis (TB) is essential for appropriate healthcare seeking behaviour and to accessing diagnosis and treatment services timely. There are several factors influencing knowledge about TB. The present study was conducted to assess the change in community knowledge of Tuberculosis (TB) and its association with respondent's socio-demographic characteristics in two serial knowledge-attitude-practice surveys. Community level interventions including community meetings with youth groups, village health committees and self-help groups and through mass media activities were undertaken to create awareness and knowledge about TB and service availability. Increase in knowledge on TB and its association with respondent's socio-demographic characteristics was assessed by two serial KAP surveys in 2010-2011 (baseline) and 2012-2013 (midline) in 30 districts of India. Correct knowledge of TB was assessed by using lead questions and scores were assigned. The composite score was dichotomized into two groups (score 0-6, poor TB knowledge and score 7-13, good TB knowledge). In baseline and midline survey, 4562 and 4808 individuals were interviewed. The correct knowledge about TB; cough ≥2 weeks, transmission through air, 6-8 months treatment duration, and free treatment increased by 7 % (p-value <0.05), 11 % (p-value <0.05), 2 % (p-value <0.05), and 8 % (p-value <0.05) in midline compared to baseline, respectively. The knowledge on sputum smear test for diagnosis of TB was 66 % in both surveys while knowledge on availability of free treatment and that TB is curable disease decreased by 5 % and 2 % in midline (p-0.001), compared to baseline, respectively. The mean score for correct knowledge about TB increased from 60 % in baseline to 71 % in midline which is a 11 % increase (p-value <0.001). The misconception regarding on transmission of TB by- sharing of food and clothes and handshake persisted in midline. Respondents residing in northern (OR, 2.2, 95 % CI, 1.7-2.6) and western districts (OR, 3.4, 95 % CI, 2.7-4.1) of India and age groups- 25-34 years (OR, 1.3; 95 % CI, 1.1-1.6) and 45-44 years (OR, 1.4; 95 % CI, 1.1-1.7)- were independently associated with good TB knowledge. The knowledge about TB has increased over a period of 2 years and this may be attributable to the community intervention in 30 districts of India. The study offers valuable lesson for designing TB related awareness programmes in India and in other high burden countries.

  10. [Fast discrimination of edible vegetable oil based on Raman spectroscopy].

    PubMed

    Zhou, Xiu-Jun; Dai, Lian-Kui; Li, Sheng

    2012-07-01

    A novel method to fast discriminate edible vegetable oils by Raman spectroscopy is presented. The training set is composed of different edible vegetable oils with known classes. Based on their original Raman spectra, baseline correction and normalization were applied to obtain standard spectra. Two characteristic peaks describing the unsaturated degree of vegetable oil were selected as feature vectors; then the centers of all classes were calculated. For an edible vegetable oil with unknown class, the same pretreatment and feature extraction methods were used. The Euclidian distances between the feature vector of the unknown sample and the center of each class were calculated, and the class of the unknown sample was finally determined by the minimum distance. For 43 edible vegetable oil samples from seven different classes, experimental results show that the clustering effect of each class was more obvious and the class distance was much larger with the new feature extraction method compared with PCA. The above classification model can be applied to discriminate unknown edible vegetable oils rapidly and accurately.

  11. Variable effects of a behavioral treatment package on the performance of inline roller speed skaters.

    PubMed Central

    Anderson, Gayla; Kirkpatrick, Michael A

    2002-01-01

    We investigated the effects of a treatment package on the performance of correct relay tags with 4 inline speed skaters. The treatment package included verbal praise following correct tags, visual feedback of performance data, and instruction for improving performance. Initial gains in the frequency of correct tags were not maintained at 6-month follow-up when baselines were reestablished. Performance on the second intervention phase for the 3 original subjects was variable and differed from the initial phase, whereas the original findings were replicated in the 4th subject. Possible reasons for this variability and implications for future research and behavioral sport interventions are considered. PMID:12102140

  12. Variable effects of a behavioral treatment package on the performance of inline roller speed skaters.

    PubMed

    Anderson, Gayla; Kirkpatrick, Michael A

    2002-01-01

    We investigated the effects of a treatment package on the performance of correct relay tags with 4 inline speed skaters. The treatment package included verbal praise following correct tags, visual feedback of performance data, and instruction for improving performance. Initial gains in the frequency of correct tags were not maintained at 6-month follow-up when baselines were reestablished. Performance on the second intervention phase for the 3 original subjects was variable and differed from the initial phase, whereas the original findings were replicated in the 4th subject. Possible reasons for this variability and implications for future research and behavioral sport interventions are considered.

  13. Determination of alcohol and extract concentration in beer samples using a combined method of near-infrared (NIR) spectroscopy and refractometry.

    PubMed

    Castritius, Stefan; Kron, Alexander; Schäfer, Thomas; Rädle, Matthias; Harms, Diedrich

    2010-12-22

    A new approach of combination of near-infrared (NIR) spectroscopy and refractometry was developed in this work to determine the concentration of alcohol and real extract in various beer samples. A partial least-squares (PLS) regression, as multivariate calibration method, was used to evaluate the correlation between the data of spectroscopy/refractometry and alcohol/extract concentration. This multivariate combination of spectroscopy and refractometry enhanced the precision in the determination of alcohol, compared to single spectroscopy measurements, due to the effect of high extract concentration on the spectral data, especially of nonalcoholic beer samples. For NIR calibration, two mathematical pretreatments (first-order derivation and linear baseline correction) were applied to eliminate light scattering effects. A sample grouping of the refractometry data was also applied to increase the accuracy of the determined concentration. The root mean squared errors of validation (RMSEV) of the validation process concerning alcohol and extract concentration were 0.23 Mas% (method A), 0.12 Mas% (method B), and 0.19 Mas% (method C) and 0.11 Mas% (method A), 0.11 Mas% (method B), and 0.11 Mas% (method C), respectively.

  14. Hypoxic Challenge Testing (Fitness to Fly) in children with complex congenital heart disease.

    PubMed

    Naqvi, Nitha; Doughty, Victoria L; Starling, Luke; Franklin, Rodney C; Ward, Simon; Daubeney, Piers E F; Balfour-Lynn, Ian M

    2018-02-14

    Commercial airplanes fly with an equivalent cabin fraction of inspired oxygen of 0.15, leading to reduced oxygen saturation (SpO 2 ) in passengers. How this affects children with complex congenital heart disease (CHD) is unknown. We conducted Hypoxic Challenge Testing (HCT) to assess need for inflight supplemental oxygen. Children aged <16 years had a standard HCT. They were grouped as (A) normal versus abnormal baseline SpO 2 (≥95% vs <95%) and (B) absence versus presence of an actual/potential right-to-left (R-L) shunt. We measured SpO 2 , heart rate, QT interval corrected for heart rate and partial pressure of carbon dioxide measured transcutaneously (PtcCO 2 ). A test failed when children with (1) normal baseline SpO 2 desaturated to 85%, (2) baseline SpO 2 85%-94% desaturated by 15% of baseline; and (3) baseline SpO 2 75%-84% desaturated to 70%. There were 68 children, mean age 3.3 years (range 10 weeks-14.5 years). Children with normal (n=36) baseline SpO 2 desaturated from median 99% to 91%, P<0.0001, and 3/36 (8%) failed the test. Those with abnormal baseline SpO 2 (n=32) desaturated from median 84% to 76%, P<0.0001, and 5/32 (16%) failed (no significant difference between groups). Children with no R-L shunt (n=25) desaturated from median 99% to 93%, P<0.0001, but 0/25 failed. Those with an actual/potential R-L shunt (n=43) desaturated from median 87% to 78%, P<0.0001, and 8/43 (19%) failed (difference between groups P<0.02). PtcCO 2 , heart rate and QT interval corrected for heart rate were unaffected by the hypoxic state. This is the first evidence to help guide which children with CHD need a preflight HCT. We suggest all children with an actual or potential R-L shunt should be tested. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Discriminating modes of toxic action in mice using toxicity in BALB/c mouse fibroblast (3T3) cells.

    PubMed

    Huang, Tao; Yan, Lichen; Zheng, Shanshan; Wang, Yue; Wang, Xiaohong; Fan, Lingyun; Li, Chao; Zhao, Yuanhui; Martyniuk, Christopher J

    2017-12-01

    The objective of this study was to determine whether toxicity in mouse fibroblast cells (3T3 cells) could predict toxicity in mice. Synthesized data on toxicity was subjected to regression analysis and it was observed that relationship of toxicities between mice and 3T3 cells was not strong (R 2  = 0.41). Inclusion of molecular descriptors (e.g. ionization, pKa) improved the regression to R 2  = 0.56, indicating that this relationship is influenced by kinetic processes of chemicals or specific toxic mechanisms associated to the compounds. However, to determine if we were able to discriminate modes of action (MOAs) in mice using the toxicities generated from 3T3 cells, compounds were first classified into "baseline" and "reactive" guided by the toxic ratio (TR) for each compound in mice. Sequence, binomial and recursive partitioning analyses provided strong predictions of MOAs in mice based upon toxicities in 3T3 cells. The correct classification of MOAs based on these methods was 86%. Nearly all the baseline compounds predicted from toxicities in 3T3 cells were identified as baseline compounds from the TR in mice. The incorrect assignment of MOAs for some compounds is hypothesized to be due to experimental uncertainty that exists in toxicity assays for both mice and 3T3 cells. Conversely, lack of assignment can also arise because some reactive compounds have MOAs that are different in mice compared to 3T3 cells. The methods developed here are novel and contribute to efforts to reduce animal numbers in toxicity tests that are used to evaluate risks associated with organic pollutants in the environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Trial occlusion to assess the risk of persistent pulmonary arterial hypertension after closure of a large patent ductus arteriosus in adolescents and adults with elevated pulmonary artery pressure.

    PubMed

    Zhang, Duan-Zhen; Zhu, Xian-Yang; Lv, Bei; Cui, Chun-Sheng; Han, Xiu-Min; Sheng, Xiao-Tang; Wang, Qi-Guang; Zhang, Po

    2014-08-01

    No method is available to predict whether patients with patent ductus arteriosus (PDA) and severe pulmonary arterial hypertension (PAH) will show persistent postprocedural PAH (PP-PAH) after PDA closure. This study evaluated the usefulness of trial occlusion for predicting PP-PAH after transcatheter PDA closure in patients with severe PAH. Trial occlusion was performed in 137 patients (age ≥12 years) with PDA and severe PAH. All patients undergoing trial occlusion had a mean pulmonary artery pressure ≥45 mm Hg, pulmonary:systemic flow (Qp/Qs) ratio >1.5, and pulmonary:systemic resistance (Rp/Rs) ratio <0.7. A total of 135 patients (98%) showing stable hemodynamics during occlusion trial underwent successful device closure. Linear correlation analysis revealed weak or moderate relationships between the baseline and post-trial pulmonary artery pressures and pulmonary:systemic pressure (Pp/Ps) ratios. Patients were followed up for 1 to 10 years (median: 5 years). PP-PAH (systolic pulmonary artery pressure >50 mm Hg by Doppler echocardiography) was detected in 17 patients (13%), who displayed no significant differences in sex and age compared with patients without PP-PAH. According to discriminant analysis, the strongest discriminators between patients with and without PP-PAH were the baseline left ventricular end-diastolic volume and the baseline and post-trial systolic Pp/Ps ratios. In particular, a post-trial systolic Pp/Ps ratio >0.5 correctly classified 100% of the PP-PAH and non-PAH patients. Trial occlusion is a feasible method to predict PP-PAH in patients with PDA and severe PAH. A post-trial systolic Pp/Ps ratio >0.5 indicates a high risk of PP-PAH occurrence after device closure. © 2014 American Heart Association, Inc.

  17. [A practical procedure to improve the accuracy of radiochromic film dosimetry: a integration with a correction method of uniformity correction and a red/blue correction method].

    PubMed

    Uehara, Ryuzo; Tachibana, Hidenobu; Ito, Yasushi; Yoshino, Shinichi; Matsubayashi, Fumiyasu; Sato, Tomoharu

    2013-06-01

    It has been reported that the light scattering could worsen the accuracy of dose distribution measurement using a radiochromic film. The purpose of this study was to investigate the accuracy of two different films, EDR2 and EBT2, as film dosimetry tools. The effectiveness of a correction method for the non-uniformity caused from EBT2 film and the light scattering was also evaluated. In addition the efficacy of this correction method integrated with the red/blue correction method was assessed. EDR2 and EBT2 films were read using a flatbed charge-coupled device scanner (EPSON 10000G). Dose differences on the axis perpendicular to the scanner lamp movement axis were within 1% with EDR2, but exceeded 3% (Maximum: +8%) with EBT2. The non-uniformity correction method, after a single film exposure, was applied to the readout of the films. A corrected dose distribution data was subsequently created. The correction method showed more than 10%-better pass ratios in dose difference evaluation than when the correction method was not applied. The red/blue correction method resulted in 5%-improvement compared with the standard procedure that employed red color only. The correction method with EBT2 proved to be able to rapidly correct non-uniformity, and has potential for routine clinical IMRT dose verification if the accuracy of EBT2 is required to be similar to that of EDR2. The use of red/blue correction method may improve the accuracy, but we recommend we should use the red/blue correction method carefully and understand the characteristics of EBT2 for red color only and the red/blue correction method.

  18. Effect of education and language on baseline concussion screening tests in professional baseball players.

    PubMed

    Jones, Nathaniel S; Walter, Kevin D; Caplinger, Roger; Wright, Daniel; Raasch, William G; Young, Craig

    2014-07-01

    The purpose of the present study was to investigate the possible effects of sociocultural influences, specifically pertaining to language and education, on baseline neuropsychological concussion testing as obtained via immediate postconcussion assessment and cognitive testing (ImPACT) of players from a professional baseball team. A retrospective chart review. Baseline testing of a professional baseball organization. Four hundred five professional baseball players. Age, languages spoken, hometown country location (United States/Canada vs overseas), and years of education. The 5 ImPACT composite scores (verbal memory, visual memory, visual motor speed, reaction time, impulse control) and ImPACT total symptom score from the initial baseline testing. The result of t tests revealed significant differences (P < 0.05) when comparing native English to native Spanish speakers in many scores. Even when corrected for education, the significant differences (P < 0.05) remained in some scores. Sociocultural differences may result in differences in computer-based neuropsychological testing scores.

  19. Visual Acuity Change over 12 Months in the Prospective Progression of Atrophy Secondary to Stargardt Disease (ProgStar) Study: ProgStar Report Number 6.

    PubMed

    Kong, Xiangrong; Strauss, Rupert W; Cideciyan, Artur V; Michaelides, Michel; Sahel, José-Alain; Munoz, Beatriz; Ahmed, Mohamed; Ervin, Ann M; West, Sheila K; Cheetham, Janet K; Scholl, Hendrik P N

    2017-11-01

    To estimate the yearly rate of change of best-corrected visual acuity (BCVA) and the risk of loss 1 line or more over 1 year and to identify risk factors for BCVA loss in patients with Stargardt disease (STGD1). Multicenter, prospective cohort study. Two hundred fifty-nine patients (489 eyes) with molecularly confirmed STGD1 enrolled at 9 centers in the United States and Europe. Participants were followed up every 6 months, and data at the baseline and 6- and 12-month visits were analyzed. Best-corrected visual acuity was measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) protocol. Standardized reporting forms were used to collect participants' characteristics and clinical observations. Linear mixed effects models were used to estimate the rate of BCVA loss. Linear models with generalized estimating equations were used to identify risk factors for BCVA loss of 1 line or more over 1 year. Change in BCVA over 1 year. Cross-sectional analysis at baseline showed that earlier symptom onset and longer duration since onset was associated with worse BCVA. Longitudinal analysis showed no overall significant change of BCVA within 12 months, but the rate of BCVA change was significantly different by baseline BCVA (P < 0.001). The BCVA of eyes with baseline BCVA of 20/25 or better declined at a rate of 2.8 ETDRS letters per year (P = 0.10), eyes with baseline BCVA between 20/25 and 20/70 declined at a rate of 2.3 ETDRS letters per year (P = 0.002), eyes with baseline BCVA between 20/70 and 20/200 declined at a rate of 0.8 ETDRS letters per year (P = 0.08), and eyes with baseline BCVA worse than 20/200 showed a significant improvement of 2.3 ETDRS letters per year (P < 0.001). Overall, 12.9% of eyes lost 1 line or more, and the risk of such BCVA loss was different by baseline BCVA level (P = 0.016). Smoking and vitamin A use was not associated significantly with baseline BCVA, nor with rate of BCVA loss over 1 year. Change in BCVA in STGD1 patients over a 12-month period was small, but varied depending on baseline BCVA. Given the slow change during 1 year, BCVA is unlikely to be a sensitive outcome measure for STGD1 treatment trials with 1 year's duration. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. THE EFFECT OF FEEDBACK ON THE ACCURACY OF CHECKLIST COMPLETION DURING INSTRUMENT FLIGHT TRAINING

    PubMed Central

    Rantz, William G; Dickinson, Alyce M; Sinclair, Gilbert A; Van Houten, Ron

    2009-01-01

    This study examined whether pilots completed airplane checklists more accurately when they receive postflight graphic and verbal feedback. Participants were 8 college students who are pilots with an instrument rating. The task consisted of flying a designated flight pattern using a personal computer aviation training device (PCATD). The dependent variables were the number of checklist items completed correctly. A multiple baseline design across pairs of participants with withdrawal of treatment was employed in this study. During baseline, participants were given postflight technical feedback. During intervention, participants were given postflight graphic feedback on checklist use and praise for improvements along with technical feedback. The intervention produced near perfect checklist performance, which was maintained following a return to the baseline conditions. PMID:20190914

  1. Thrust performance of a variable-geometry, divergent exhaust nozzle on a turbojet engine at altitude

    NASA Technical Reports Server (NTRS)

    Straight, D. M.; Collom, R. R.

    1983-01-01

    A variable geometry, low aspect ratio, nonaxisymmetric, two dimensional, convergent-divergent exhaust nozzle was tested at simulated altitude on a turbojet engine to obtain baseline axial, dry thrust performance over wide ranges of operating nozzle pressure ratios, throat areas, and internal expansion area ratios. The thrust data showed good agreement with theory and scale model test results after the data were corrected for seal leakage and coolant losses. Wall static pressure profile data were also obtained and compared with one dimensional theory and scale model data. The pressure data indicate greater three dimensional flow effects in the full scale tests than with models. The leakage and coolant penalties were substantial, and the method to determine them is included.

  2. US-SOMO HPLC-SAXS module: dealing with capillary fouling and extraction of pure component patterns from poorly resolved SEC-SAXS data

    PubMed Central

    Brookes, Emre; Vachette, Patrice; Rocco, Mattia; Pérez, Javier

    2016-01-01

    Size-exclusion chromatography coupled with SAXS (small-angle X-ray scattering), often performed using a flow-through capillary, should allow direct collection of monodisperse sample data. However, capillary fouling issues and non-baseline-resolved peaks can hamper its efficacy. The UltraScan solution modeler (US-SOMO) HPLC-SAXS (high-performance liquid chromatography coupled with SAXS) module provides a comprehensive framework to analyze such data, starting with a simple linear baseline correction and symmetrical Gaussian decomposition tools [Brookes, Pérez, Cardinali, Profumo, Vachette & Rocco (2013 ▸). J. Appl. Cryst. 46, 1823–1833]. In addition to several new features, substantial improvements to both routines have now been implemented, comprising the evaluation of outcomes by advanced statistical tools. The novel integral baseline-correction procedure is based on the more sound assumption that the effect of capillary fouling on scattering increases monotonically with the intensity scattered by the material within the X-ray beam. Overlapping peaks, often skewed because of sample interaction with the column matrix, can now be accurately decomposed using non-symmetrical modified Gaussian functions. As an example, the case of a polydisperse solution of aldolase is analyzed: from heavily convoluted peaks, individual SAXS profiles of tetramers, octamers and dodecamers are extracted and reliably modeled. PMID:27738419

  3. Erratum to. Measurement of the inclusive jet cross-section in proton-proton collisions at √s=7 TeV using 4.5 fb -1 of data with the ATLAS detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aad, G.; Abbott, B.; Abdallah, J.

    2015-09-01

    We found that the non-perturbative corrections calculated using Pythia with the Perugia 2011 tune did not include the effect of the underlying event. The affected correction factors were recomputed using the Pythia 6.427 generator. These corrections are applied as baseline to the NLO pQCD calculations and thus the central values of the theoretical predictions have changed by a few percent with the new corrections. This has a minor impact on the agreement between the data and the theoretical predictions. Figures 2 and 6 to 13, and all the tables have been updated with the new values. A few sentences inmore » the discussion in sections 5.2 and 9 were altered or removed.« less

  4. Treatment with a combination of intra-oral sensory stimulation and electropalatography in a child with severe developmental dyspraxia.

    PubMed

    Lundeborg, Inger; McAllister, Anita

    2007-01-01

    This paper describes the use of a combination of intra-oral sensory stimulation and electropalatography (EPG) in the treatment of a case with severe developmental verbal dyspraxia. A multiple-baseline design was used. The treatment duration was 11 months and started when the subject was 5 years old. The efficacy of the treatment was assessed by calculations of percentage of correctly articulated words, percentage of consonants correct, percentage of phonemes correct and percentage of words correct. Intelligibility assessments were conducted by both naïve and expert listeners. The experts also assessed visual deviances in articulatory gestures from video recordings. Qualitative analysis of EPG data was made. The subject's speech was significantly improved by the treatment in all aspects. The results and their generalization to other cases of developmental verbal dyspraxia are discussed.

  5. Can I Count on Getting Better? Association between Math Anxiety and Poorer Understanding of Medical Risk Reductions.

    PubMed

    Rolison, Jonathan J; Morsanyi, Kinga; O'Connor, Patrick A

    2016-10-01

    Lower numerical ability is associated with poorer understanding of health statistics, such as risk reductions of medical treatment. For many people, despite good numeracy skills, math provokes anxiety that impedes an ability to evaluate numerical information. Math-anxious individuals also report less confidence in their ability to perform math tasks. We hypothesized that, independent of objective numeracy, math anxiety would be associated with poorer responding and lower confidence when calculating risk reductions of medical treatments. Objective numeracy was assessed using an 11-item objective numeracy scale. A 13-item self-report scale was used to assess math anxiety. In experiment 1, participants were asked to interpret the baseline risk of disease and risk reductions associated with treatment options. Participants in experiment 2 were additionally provided a graphical display designed to facilitate the processing of math information and alleviate effects of math anxiety. Confidence ratings were provided on a 7-point scale. Individuals of higher objective numeracy were more likely to respond correctly to baseline risks and risk reductions associated with treatment options and were more confident in their interpretations. Individuals who scored high in math anxiety were instead less likely to correctly interpret the baseline risks and risk reductions and were less confident in their risk calculations as well as in their assessments of the effectiveness of treatment options. Math anxiety predicted confidence levels but not correct responding when controlling for objective numeracy. The graphical display was most effective in increasing confidence among math-anxious individuals. The findings suggest that math anxiety is associated with poorer medical risk interpretation but is more strongly related to confidence in interpretations. © The Author(s) 2015.

  6. Botulinum toxin type A (Botox) for the neuromuscular correction of excessive gingival display on smiling (gummy smile).

    PubMed

    Polo, Mario

    2008-02-01

    Previously, botulinum toxin type A (BTX-A) (Botox; Allergan, Irvine, Calif) was shown to be effective in reducing excessive gingival display in 5 patients with gummy smiles. This study was conducted to determine whether the doses and the primary injection sites used in the pilot study for the correction of gummy smiles provide consistent, statistically significant, and esthetically pleasing results. Thirty patients received BTX-A injections to reduce excessive gingival display. Gingival display was defined as the difference between the lower margin of the upper lip and the superior margin of the right incisor. Patients were followed at 2, 4, 8, 12, 16, 20, and 24 weeks postinjection, with changes documented by photographs and videos. At week 2, the patients rated the effects of BTX-A. A group of specialty clinicians also evaluated the effects of BTX-A. Preinjection gingival display averaged 5.2 +/- 1.4 mm in the 30 patients. At 2 weeks postinjection, mean gingival display had declined to 0.09 mm (+/- 1.06 mm) in 30 patients (t = 26.01, P <.00001). The average lip-drop at 2 weeks was 5.1 mm for 30 patients. Gingival display gradually increased from 2 weeks postinjection through 24 weeks, but, at 24 weeks, average gingival display had not returned to baseline values. Based on predictions from a third-order polynomial equation, the baseline average of 5.2 mm would not be reached until 30 to 32 weeks postinjection. Patients and specialty evaluators rated the effects of BTX-A as highly favorable. BTX-A injections for the neuromuscular correction of gummy smiles caused by hyperfunctional upper lip elevator muscles was effective and statistically superior to baseline smiles, although the effect is transitory.

  7. Knowledge and skills for management of sexually transmitted infections among rural medical practitioners in Bangladesh.

    PubMed

    Alam, Nazmul; Mridha, Malay K; Kristensen, Sibylle; Vermund, Sten H

    2015-04-01

    Sexually transmitted infection (STI) management is considered rudimentary among rural medical practitioners (RMPs) in Bangladesh. We sought to understand the level of knowledge and skills in STI management and to assess the impact of a two-day training orientation among RMPs in Tangail district. Data were collected through a baseline survey of 225 practicing RMPs in the study area and a three-month follow-up survey of 99 RMPs who participated in a two-day STI/HIV orientation training. The level of formal training among RMPs ranged from none (22.7%), to paramedical training (14.7%) and local medical assistant training (62.6%). The baseline survey revealed a low level of STI/HIV knowledge and misconceptions about the transmission of STI/HIV among RMPs. RMPs mostly prescribed first line antibiotics for treatment of common reproductive tract infections (RTIs) including STIs, but they rarely prescribed the correct dosages according to the national RTI/STI management guidelines. Only 3% of RMPs were able to correctly answer all four HIV transmission (unprotected sexual intercourse, blood transfusion, needle sharing and mother to child transmission) questions at baseline, while 94.9% of RMPs answered all four correctly at three months following the training (p=0.001). Only 10% of RMPs reported suggesting the recommended drug (azithromycin) and only 2% mentioned about the recommended dosage (2gm single dose) for the treatment of urethritis/cervicitis; compared to 49.5% suggested azithromycin at follow-up with 39.4% mentioned the recommended 2gm single dose (p=0.001). Our study found low level of knowledge and poor practices related RTI/STI management among RMPs. Short orientation training and education intervention shown promise to increase knowledge and management skills for RTIs/STIs.

  8. Knowledge and skills for management of sexually transmitted infections among rural medical practitioners in Bangladesh

    PubMed Central

    Alam, Nazmul; Mridha, Malay K.; Kristensen, Sibylle; Vermund, Sten H.

    2015-01-01

    Sexually transmitted infection (STI) management is considered rudimentary among rural medical practitioners (RMPs) in Bangladesh. We sought to understand the level of knowledge and skills in STI management and to assess the impact of a two-day training orientation among RMPs in Tangail district. Data were collected through a baseline survey of 225 practicing RMPs in the study area and a three-month follow-up survey of 99 RMPs who participated in a two-day STI/HIV orientation training. The level of formal training among RMPs ranged from none (22.7%), to paramedical training (14.7%) and local medical assistant training (62.6%). The baseline survey revealed a low level of STI/HIV knowledge and misconceptions about the transmission of STI/HIV among RMPs. RMPs mostly prescribed first line antibiotics for treatment of common reproductive tract infections (RTIs) including STIs, but they rarely prescribed the correct dosages according to the national RTI/STI management guidelines. Only 3% of RMPs were able to correctly answer all four HIV transmission (unprotected sexual intercourse, blood transfusion, needle sharing and mother to child transmission) questions at baseline, while 94.9% of RMPs answered all four correctly at three months following the training (p=0.001). Only 10% of RMPs reported suggesting the recommended drug (azithromycin) and only 2% mentioned about the recommended dosage (2gm single dose) for the treatment of urethritis/cervicitis; compared to 49.5% suggested azithromycin at follow-up with 39.4% mentioned the recommended 2gm single dose (p=0.001). Our study found low level of knowledge and poor practices related RTI/STI management among RMPs. Short orientation training and education intervention shown promise to increase knowledge and management skills for RTIs/STIs. PMID:25954593

  9. Stroke education using an animated cartoon and a manga for junior high school students.

    PubMed

    Shigehatake, Yuya; Yokota, Chiaki; Amano, Tatsuo; Tomii, Yasuhiro; Inoue, Yasuteru; Hagihara, Takaaki; Toyoda, Kazunori; Minematsu, Kazuo

    2014-07-01

    We investigated whether junior high school students could be educated regarding stroke with an animated cartoon and a Manga that we produced for the purpose of dissemination of this knowledge. We produced a 10-minute animated cartoon and a Manga that provided information regarding stroke risk factors, stroke signs and symptoms, and awareness to immediately contact emergent medical service (EMS) on identification of stroke signs and symptoms. From December 2011 to March 2012, 493 students in 15 classes of the first grade (age 12-13 years) of 3 junior high schools were enrolled in the study. Each subject watched the animated cartoon and read the Manga; this was referred to as "training." Lessons about stroke were not given. Questionnaires on stroke knowledge were evaluated at baseline, immediately after the training, and 3 months after the training. The proportion of correct answers given immediately after the training was higher for all questions, except those related to arrhythmia, compared with baseline. Percentage of correct answers given at 3 months was higher than that at baseline in questions related to facial palsy (75% versus 33%), speech disturbance (91% versus 60%), hemiplegia (79% versus 52%), numbness of 1 side (58% versus 51%), calling for EMS (90% versus 85%), alcohol intake (96% versus 72%), and smoking (69% versus 54%). At 3 months after the training, 56% of students answered the FAST (facial droop, arm weakness, speech disturbance, time to call for EMS) mnemonic correctly. Stroke education using these teaching aids of the animated cartoon and the Manga improved stroke knowledge in junior high school students. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  10. Dexamethasone Stimulated Gene Expression in Peripheral Blood is a Sensitive Marker for Glucocorticoid Receptor Resistance in Depressed Patients

    PubMed Central

    Menke, Andreas; Arloth, Janine; Pütz, Benno; Weber, Peter; Klengel, Torsten; Mehta, Divya; Gonik, Mariya; Rex-Haffner, Monika; Rubel, Jennifer; Uhr, Manfred; Lucae, Susanne; Deussing, Jan M; Müller-Myhsok, Bertram; Holsboer, Florian; Binder, Elisabeth B

    2012-01-01

    Although gene expression profiles in peripheral blood in major depression are not likely to identify genes directly involved in the pathomechanism of affective disorders, they may serve as biomarkers for this disorder. As previous studies using baseline gene expression profiles have provided mixed results, our approach was to use an in vivo dexamethasone challenge test and to compare glucocorticoid receptor (GR)-mediated changes in gene expression between depressed patients and healthy controls. Whole genome gene expression data (baseline and following GR-stimulation with 1.5 mg dexamethasone p.o.) from two independent cohorts were analyzed to identify gene expression pattern that would predict case and control status using a training (N=18 cases/18 controls) and a test cohort (N=11/13). Dexamethasone led to reproducible regulation of 2670 genes in controls and 1151 transcripts in cases. Several genes, including FKBP5 and DUSP1, previously associated with the pathophysiology of major depression, were found to be reliable markers of GR-activation. Using random forest analyses for classification, GR-stimulated gene expression outperformed baseline gene expression as a classifier for case and control status with a correct classification of 79.1 vs 41.6% in the test cohort. GR-stimulated gene expression performed best in dexamethasone non-suppressor patients (88.7% correctly classified with 100% sensitivity), but also correctly classified 77.3% of the suppressor patients (76.7% sensitivity), when using a refined set of 19 genes. Our study suggests that in vivo stimulated gene expression in peripheral blood cells could be a promising molecular marker of altered GR-functioning, an important component of the underlying pathology, in patients suffering from depressive episodes. PMID:22237309

  11. Multimodal intraoperative neuromonitoring in corrective surgery for adolescent idiopathic scoliosis: Evaluation of 354 consecutive cases

    PubMed Central

    Kundnani, Vishal K; Zhu, Lisa; Tak, HH; Wong, HK

    2010-01-01

    Background: Multimodal intraoperative neuromonitoring is recommended during corrective spinal surgery, and has been widely used in surgery for spinal deformity with successful outcomes. Despite successful outcomes of corrective surgery due to increased safety of the patients with the usage of spinal cord monitoring in many large spine centers, this modality has not yet achieved widespread popularity. We report the analysis of prospectively collected intraoperative neurophysiological monitoring data of 354 consecutive patients undergoing corrective surgery for adolescent idiopathic scoliosis (AIS) to establish the efficacy of multimodal neuromonitoring and to evaluate comparative sensitivity and specificity. Materials and Methods: The study group consisted of 354 (female = 309; male = 45) patients undergoing spinal deformity corrective surgery between 2004 and 2008. Patients were monitored using electrophysiological methods including somatosensory-evoked potentials and motor-evoked potentials simultaneously. Results: Mean age of patients was 13.6 years (±2.3 years). The operative procedures involved were instrumented fusion of the thoracic/lumbar/both curves, Baseline somatosensory-evoked potentials (SSEP) and neurogenic motor-evoked potentials (NMEP) were recorded successfully in all cases. Thirteen cases expressed significant alert to prompt reversal of intervention. All these 13 cases with significant alert had detectable NMEP alerts, whereas significant SSEP alert was detected in 8 cases. Two patients awoke with new neurological deficit (0.56%) and had significant intraoperative SSEP + NMEP alerts. There were no false positives with SSEP (high specificity) but 5 patients with false negatives with SSEP (38%) reduced its sensitivity. There was no false negative with NMEP but 2 of 13 cases were false positive with NMEP (15%). The specificity of SSEP (100%) is higher than NMEP (96%); however, the sensitivity of NMEP (100%) is far better than SSEP (51%). Due to these results, the overall sensitivity, specificity and positive predictive value of combined multimodality neuromonitoring in this adult deformity series was 100, 98.5 and 85%, respectively. Conclusion: Neurogenic motor-evoked potential (NMEP) monitoring appears to be superior to conventional SSEP monitoring for identifying evolving spinal cord injury. Used in conjunction, the sensitivity and specificity of combined neuromonitoring may reach up to 100%. Multimodality monitoring with SSEP + NMEP should be the standard of care. PMID:20165679

  12. Research on Wide-field Imaging Technologies for Low-frequency Radio Array

    NASA Astrophysics Data System (ADS)

    Lao, B. Q.; An, T.; Chen, X.; Wu, X. C.; Lu, Y.

    2017-09-01

    Wide-field imaging of low-frequency radio telescopes are subject to a number of difficult problems. One particularly pernicious problem is the non-coplanar baseline effect. It will lead to distortion of the final image when the phase of w direction called w-term is ignored. The image degradation effects are amplified for telescopes with the wide field of view. This paper summarizes and analyzes several w-term correction methods and their technical principles. Their advantages and disadvantages have been analyzed after comparing their computational cost and computational complexity. We conduct simulations with two of these methods, faceting and w-projection, based on the configuration of the first-phase Square Kilometre Array (SKA) low frequency array. The resulted images are also compared with the two-dimensional Fourier transform method. The results show that image quality and correctness derived from both faceting and w-projection are better than the two-dimensional Fourier transform method in wide-field imaging. The image quality and run time affected by the number of facets and w steps have been evaluated. The results indicate that the number of facets and w steps must be reasonable. Finally, we analyze the effect of data size on the run time of faceting and w-projection. The results show that faceting and w-projection need to be optimized before the massive amounts of data processing. The research of the present paper initiates the analysis of wide-field imaging techniques and their application in the existing and future low-frequency array, and fosters the application and promotion to much broader fields.

  13. Calibration of Ocean Forcing with satellite Flux Estimates (COFFEE)

    NASA Astrophysics Data System (ADS)

    Barron, Charlie; Jan, Dastugue; Jackie, May; Rowley, Clark; Smith, Scott; Spence, Peter; Gremes-Cordero, Silvia

    2016-04-01

    Predicting the evolution of ocean temperature in regional ocean models depends on estimates of surface heat fluxes and upper-ocean processes over the forecast period. Within the COFFEE project (Calibration of Ocean Forcing with satellite Flux Estimates, real-time satellite observations are used to estimate shortwave, longwave, sensible, and latent air-sea heat flux corrections to a background estimate from the prior day's regional or global model forecast. These satellite-corrected fluxes are used to prepare a corrected ocean hindcast and to estimate flux error covariances to project the heat flux corrections for a 3-5 day forecast. In this way, satellite remote sensing is applied to not only inform the initial ocean state but also to mitigate errors in surface heat flux and model representations affecting the distribution of heat in the upper ocean. While traditional assimilation of sea surface temperature (SST) observations re-centers ocean models at the start of each forecast cycle, COFFEE endeavors to appropriately partition and reduce among various surface heat flux and ocean dynamics sources. A suite of experiments in the southern California Current demonstrates a range of COFFEE capabilities, showing the impact on forecast error relative to a baseline three-dimensional variational (3DVAR) assimilation using operational global or regional atmospheric forcing. Experiment cases combine different levels of flux calibration with assimilation alternatives. The cases use the original fluxes, apply full satellite corrections during the forecast period, or extend hindcast corrections into the forecast period. Assimilation is either baseline 3DVAR or standard strong-constraint 4DVAR, with work proceeding to add a 4DVAR expanded to include a weak constraint treatment of the surface flux errors. Covariance of flux errors is estimated from the recent time series of forecast and calibrated flux terms. While the California Current examples are shown, the approach is equally applicable to other regions. These approaches within a 3DVAR application are anticipated to be useful for global and larger regional domains where a full 4DVAR methodology may be cost-prohibitive.

  14. Optimizing inhalation technique using web-based videos in obstructive lung diseases.

    PubMed

    Müller, Tobias; Müller, Annegret; Hübel, Christian; Knipel, Verena; Windisch, Wolfram; Cornelissen, Christian Gabriel; Dreher, Michael

    2017-08-01

    Inhaled agents are widely used in the treatment of chronic airway diseases. Correct technique is required to ensure appropriate drug deposition, but poor technique is common. This study investigated whether inhalation technique could be improved by patient training using short videos from the German Airway League. Outpatients from a university hospital respiratory clinic who had incorrect inhalation technique were asked to demonstrate this again immediately after viewing the training videos, and after 4-8 weeks' follow-up. Inhalation technique was rated by a study nurse using specific checklists. One hundred and twelve patients with obstructive lung disease treated with inhaled bronchodilators or corticosteroids were included. More than half (51.8%) had at least one mistake in inhalation technique at baseline. Of these, most (88%) understood the training videos, 76% demonstrated correct device use immediately after training, and 72% were still able to demonstrate correct inhalation technique at follow-up (p = 0.0008 for trend). In addition, the number of mistakes decreased significantly after video training (by 1.82 [95% confidence interval 1.39-2.25]; p < 0.0001 vs. baseline). German Airway League inhalation technique training videos were easy to understand and effectively improved inhalation technique in patients with airway diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Underestimated interannual variability of East Asian summer rainfall under climate change

    NASA Astrophysics Data System (ADS)

    Ren, Yongjian; Song, Lianchun; Xiao, Ying; Du, Liangmin

    2018-02-01

    This study evaluates the performance of climate models in simulating the climatological mean and interannual variability of East Asian summer rainfall (EASR) using Coupled Model Intercomparison Project Phase 5 (CMIP5). Compared to the observation, the interannual variability of EASR during 1979-2005 is underestimated by the CMIP5 with a range of 0.86 16.08%. Based on bias correction of CMIP5 simulations with historical data, the reliability of future projections will be enhanced. The corrected EASR under representative concentration pathways (RCPs) 4.5 and 8.5 increases by 5.6 and 7.5% during 2081-2100 relative to the baseline of 1986-2005, respectively. After correction, the areas with both negative and positive anomalies decrease, which are mainly located in the South China Sea and central China, and southern China and west of the Philippines, separately. In comparison to the baseline, the interannual variability of EASR increases by 20.8% under RCP4.5 but 26.2% under RCP8.5 in 2006-2100, which is underestimated by 10.7 and 11.1% under both RCPs in the original CMIP5 simulation. Compared with the mean precipitation, the interannual variability of EASR is notably larger under global warming. Thus, the probabilities of floods and droughts may increase in the future.

  16. Modifying the affective behavior of preschoolers with autism using in-vivo or video modeling and reinforcement contingencies.

    PubMed

    Gena, Angeliki; Couloura, Sophia; Kymissis, Effie

    2005-10-01

    The purpose of this study was to modify the affective behavior of three preschoolers with autism in home settings and in the context of play activities, and to compare the effects of video modeling to the effects of in-vivo modeling in teaching these children contextually appropriate affective responses. A multiple-baseline design across subjects, with a return to baseline condition, was used to assess the effects of treatment that consisted of reinforcement, video modeling, in-vivo modeling, and prompting. During training trials, reinforcement in the form of verbal praise and tokens was delivered contingent upon appropriate affective responding. Error correction procedures differed for each treatment condition. In the in-vivo modeling condition, the therapist used modeling and verbal prompting. In the video modeling condition, video segments of a peer modeling the correct response and verbal prompting by the therapist were used as corrective procedures. Participants received treatment in three categories of affective behavior--sympathy, appreciation, and disapproval--and were presented with a total of 140 different scenarios. The study demonstrated that both treatments--video modeling and in-vivo modeling--systematically increased appropriate affective responding in all response categories for the three participants. Additionally, treatment effects generalized across responses to untrained scenarios, the child's mother, new therapists, and time.

  17. Long-term impact of integration of household water treatment and hygiene promotion with antenatal services on maternal water treatment and hygiene practices in Malawi.

    PubMed

    Loharikar, Anagha; Russo, Elizabeth; Sheth, Anandi; Menon, Manoj; Kudzala, Amose; Tauzie, Blessius; Masuku, Humphreys D; Ayers, Tracy; Hoekstra, Robert M; Quick, Robert

    2013-02-01

    A clinic-based program to integrate antenatal services with distribution of hygiene kits including safe water storage containers, water treatment solution (brand name WaterGuard), soap, and hygiene education, was implemented in Malawi in 2007 and evaluated in 2010. We surveyed 389 participants at baseline in 2007, and found and surveyed 232 (60%) participants to assess water treatment, test stored drinking water for residual chlorine (an objective measure of treatment), and observe handwashing technique at follow-up in 2010. Program participants were more likely to know correct water treatment procedures (67% versus 36%; P < 0.0001), treat drinking water with WaterGuard (24% versus 2%; P < 0.0001), purchase and use WaterGuard (21% versus 1%; P < 0.001), and demonstrate correct handwashing technique (50% versus 21%; P < 0.001) at the three-year follow-up survey than at baseline. This antenatal-clinic-based program may have contributed to sustained water treatment and proper handwashing technique among program participants.

  18. Teaching students with developmental disabilities to operate an iPod Touch(®) to listen to music.

    PubMed

    Kagohara, Debora M; Sigafoos, Jeff; Achmadi, Donna; van der Meer, Larah; O'Reilly, Mark F; Lancioni, Giulio E

    2011-01-01

    We evaluated an intervention procedure for teaching three students with developmental disabilities to independently operate a portable multimedia device (i.e., an iPod Touch(®)) to listen to music. The intervention procedure included the use of video modeling, which was presented on the same iPod Touch(®) that the students were taught to operate to listen to music. Four phases (i.e., baseline, intervention, fading, and follow-up) were arranged in accordance with a delayed multiple-probe across participants design. During baseline, the students performed from 25 to 62.5% of the task analyzed steps correctly. With intervention, all three students correctly performed 80-100% of the steps and maintained this level of performance when video modeling was removed and during follow-up. The findings suggest that the video modeling procedure was effective for teaching the students to independently operate a portable multimedia device to access age-appropriate leisure content. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. First faint dual-field off-axis observations in optical long baseline interferometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woillez, J.; Wizinowich, P.; Ragland, S.

    2014-03-10

    Ground-based long baseline interferometers have long been limited in sensitivity in part by the short integration periods imposed by atmospheric turbulence. The first observation fainter than this limit was performed on 2011 January 22 when the Keck Interferometer observed a K = 11.5 target, about 1 mag fainter than its K = 10.3 atmospherically imposed limit; the currently demonstrated limit is K = 12.5. These observations were made possible by the Dual-Field Phase-Referencing (DFPR) instrument, part of the NSF-funded ASTrometry and phase-Referenced Astronomy project; integration times longer than the turbulence time scale are made possible by its ability to simultaneouslymore » measure the real-time effects of the atmosphere on a nearby bright guide star and correct for it on the faint target. We present the implementation of DFPR on the Keck Interferometer. Then, we detail its on-sky performance focusing on the accuracy of the turbulence correction and the resulting fringe contrast stability.« less

  20. Sea level static calibration of a compact multimission aircraft propulsion simulator with inlet flow distortion

    NASA Technical Reports Server (NTRS)

    Won, Mark J.

    1990-01-01

    Wind tunnel tests of propulsion-integrated aircraft models have identified inlet flow distortion as a major source of compressor airflow measurement error in turbine-powered propulsion simulators. Consequently, two Compact Multimission Aircraft Propulsion Simulator (CMAPS) units were statically tested at sea level ambient conditions to establish simulator operating performance characteristics and to calibrate the compressor airflow against an accurate bellmouth flowmeter in the presence of inlet flow distortions. The distortions were generated using various-shaped wire mesh screens placed upstream of the compressor. CMAPS operating maps and performance envelopes were obtained for inlet total pressure distortions (ratio of the difference between the maximum and minimum total pressures to the average total pressure) up to 35 percent, and were compared to baseline simulator operating characteristics for a uniform inlet. Deviations from CMAPS baseline performance were attributed to the coupled variation of both compressor inlet-flow distortion and Reynolds number index throughout the simulator operating envelope for each screen configuration. Four independent methods were used to determine CMAPS compressor airflow; direct compressor inlet and discharge measurements, an entering/exiting flow-balance relationships, and a correlation between the mixer pressure and the corrected compressor airflow. Of the four methods, the last yielded the least scatter in the compressor flow coefficient, approximately + or - 3 percent over the range of flow distortions.

  1. Development and validation of a 6-point grading scale in patients undergoing correction of nasolabial folds with a collagen implant.

    PubMed

    Monheit, Gary D; Gendler, Ellen C; Poff, Bradley; Fleming, Laura; Bachtell, Nathan; Garcia, Emily; Burkholder, David

    2010-11-01

    Various scoring techniques prone to subjective interpretation have been used to evaluate soft tissue augmentation of nasolabial folds (NLFs). To design and validate a reliable wrinkle assessment scoring scale. Six photographed wrinkles of varying severity were electronically copied onto the same facial image to become a 6-point grading scale (GGS). A pilot training program (13 investigators) determined reliability, and a 12-week multicenter survey study validated the GGS scoring method. Pilot study inter- and intrarater scoring reliability were high (weighted kappa scores of 0.85 and 0.86, respectively). Seventy-five percent of survey investigators and independent review panel (IRP) members considered a GGS score difference of 0.5 to be a minimally perceivable difference. Interrater weighted kappa scores were 0.91 for the IRP and 0.80 for investigators. Intrarater agreements after repeat testing were 0.91 and 0.89, respectively. The baseline "live" assessment GGS mean score was 3.34, and the baseline blinded photographic assessment GGS mean score was 2.00 for the IRP and 2.16 for the investigators. The GGS is a reproducible method of grading the severity of NLF wrinkles. Treatment effectiveness of a dermal filler can be reliably evaluated using the GGS by comparing "live" assessments with the standard GGS photographic panel. © 2010 by the American Society for Dermatologic Surgery, Inc.

  2. Effectiveness of individual resource-oriented joint protection education in people with rheumatoid arthritis. A randomized controlled trial.

    PubMed

    Niedermann, Karin; de Bie, Rob A; Kubli, Regula; Ciurea, Adrian; Steurer-Stey, Claudia; Villiger, Peter M; Büchi, Stefan

    2011-01-01

    the modern joint protection (JP) concept for people with rheumatoid arthritis (RA) is an active coping strategy to improve daily tasks and role performance by changing working methods and using assistive devices. Effective group JP education includes psycho-educational interventions. The Pictorial Representation of Illness and Self Measure (PRISM) is an interactive hands-on-tool, assessing (a) the individual's perceived burden of illness and (b) relevant individual resources. Both issues are important for intrinsic motivation to take action and change behaviour. This study compared individual conventional JP education (C-JP) with PRISM-based JP education (PRISM-JP). an assessor-blinded multicentre randomized controlled trial, including four JP education sessions over 3 weeks, with assessments at baseline and 3 months. in total 53 RA patients participated. At 3 months, the PRISM-JP (n=26) participants did significantly better compared to the C-JP participants (n=27) in JP behaviour (p=0.02 and p=0.008 when corrected for baseline values), Arthritis Self-efficacy (ASES, p=0.015) and JP self-efficacy (JP-SES, p=0.047). Within-group analysis also showed less hand pain (p<0.001) in PRISM-JP group. PRISM-JP more effectively supported learning of JP methods, with meaningful occupations, resource activation and self-efficacy acting as important mediators. PRISM improved patient-clinician communication and is feasible for occupational therapy. 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Comparative Analysis of a Principal Component Analysis-Based and an Artificial Neural Network-Based Method for Baseline Removal.

    PubMed

    Carvajal, Roberto C; Arias, Luis E; Garces, Hugo O; Sbarbaro, Daniel G

    2016-04-01

    This work presents a non-parametric method based on a principal component analysis (PCA) and a parametric one based on artificial neural networks (ANN) to remove continuous baseline features from spectra. The non-parametric method estimates the baseline based on a set of sampled basis vectors obtained from PCA applied over a previously composed continuous spectra learning matrix. The parametric method, however, uses an ANN to filter out the baseline. Previous studies have demonstrated that this method is one of the most effective for baseline removal. The evaluation of both methods was carried out by using a synthetic database designed for benchmarking baseline removal algorithms, containing 100 synthetic composed spectra at different signal-to-baseline ratio (SBR), signal-to-noise ratio (SNR), and baseline slopes. In addition to deomonstrating the utility of the proposed methods and to compare them in a real application, a spectral data set measured from a flame radiation process was used. Several performance metrics such as correlation coefficient, chi-square value, and goodness-of-fit coefficient were calculated to quantify and compare both algorithms. Results demonstrate that the PCA-based method outperforms the one based on ANN both in terms of performance and simplicity. © The Author(s) 2016.

  4. SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kenton, O; Valdes, G; Yin, L

    Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. Themore » calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.« less

  5. Evaluating software development by analysis of changes: The data from the software engineering laboratory

    NASA Technical Reports Server (NTRS)

    1982-01-01

    An effective data collection methodology for evaluating software development methodologies was applied to four different software development projects. Goals of the data collection included characterizing changes and errors, characterizing projects and programmers, identifying effective error detection and correction techniques, and investigating ripple effects. The data collected consisted of changes (including error corrections) made to the software after code was written and baselined, but before testing began. Data collection and validation were concurrent with software development. Changes reported were verified by interviews with programmers.

  6. A complete VLBI delay model for deforming radio telescopes: the Effelsberg case

    NASA Astrophysics Data System (ADS)

    Artz, T.; Springer, A.; Nothnagel, A.

    2014-12-01

    Deformations of radio telescopes used in geodetic and astrometric very long baseline interferometry (VLBI) observations belong to the class of systematic error sources which require correction in data analysis. In this paper we present a model for all path length variations in the geometrical optics of radio telescopes which are due to gravitational deformation. The Effelsberg 100 m radio telescope of the Max Planck Institute for Radio Astronomy, Bonn, Germany, has been surveyed by various terrestrial methods. Thus, all necessary information that is needed to model the path length variations is available. Additionally, a ray tracing program has been developed which uses as input the parameters of the measured deformations to produce an independent check of the theoretical model. In this program as well as in the theoretical model, the illumination function plays an important role because it serves as the weighting function for the individual path lengths depending on the distance from the optical axis. For the Effelsberg telescope, the biggest contribution to the total path length variations is the bending of the main beam located along the elevation axis which partly carries the weight of the paraboloid at its vertex. The difference in total path length is almost 100 mm when comparing observations at 90 and at 0 elevation angle. The impact of the path length corrections is validated in a global VLBI analysis. The application of the correction model leads to a change in the vertical position of mm. This is more than the maximum path length, but the effect can be explained by the shape of the correction function.

  7. Pilot study of the impact that bilateral sacroiliac joint manipulation using a drop table technique has on gait parameters in asymptomatic individuals with a leg length inequality.

    PubMed

    Ward, John; Sorrels, Ken; Coats, Jesse; Pourmoghaddam, Amir; Deleon, Carlos; Daigneault, Paige

    2014-03-01

    The purpose of this study was to pilot test our study procedures and estimate parameters for sample size calculations for a randomized controlled trial to determine if bilateral sacroiliac (SI) joint manipulation affects specific gait parameters in asymptomatic individuals with a leg length inequality (LLI). Twenty-one asymptomatic chiropractic students engaged in a baseline 90-second walking kinematic analysis using infrared Vicon® cameras. Following this, participants underwent a functional LLI test. Upon examination participants were classified as: left short leg, right short leg, or no short leg. Half of the participants in each short leg group were then randomized to receive bilateral corrective SI joint chiropractic manipulative therapy (CMT). All participants then underwent another 90-second gait analysis. Pre- versus post-intervention gait data were then analyzed within treatment groups by an individual who was blinded to participant group status. For the primary analysis, all p-values were corrected for multiple comparisons using the Bonferroni method. Within groups, no differences in measured gait parameters were statistically significant after correcting for multiple comparisons. The protocol of this study was acceptable to all subjects who were invited to participate. No participants refused randomization. Based on the data collected, we estimated that a larger main study would require 34 participants in each comparison group to detect a moderate effect size.

  8. PLATFORM DEFORMATION PHASE CORRECTION FOR THE AMiBA-13 COPLANAR INTERFEROMETER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, Yu-Wei; Lin, Kai-Yang; Huang, Yau-De

    2013-05-20

    We present a new way to solve the platform deformation problem of coplanar interferometers. The platform of a coplanar interferometer can be deformed due to driving forces and gravity. A deformed platform will induce extra components into the geometric delay of each baseline and change the phases of observed visibilities. The reconstructed images will also be diluted due to the errors of the phases. The platform deformations of The Yuan-Tseh Lee Array for Microwave Background Anisotropy (AMiBA) were modeled based on photogrammetry data with about 20 mount pointing positions. We then used the differential optical pointing error between two opticalmore » telescopes to fit the model parameters in the entire horizontal coordinate space. With the platform deformation model, we can predict the errors of the geometric phase delays due to platform deformation with a given azimuth and elevation of the targets and calibrators. After correcting the phases of the radio point sources in the AMiBA interferometric data, we recover 50%-70% flux loss due to phase errors. This allows us to restore more than 90% of a source flux. The method outlined in this work is not only applicable to the correction of deformation for other coplanar telescopes but also to single-dish telescopes with deformation problems. This work also forms the basis of the upcoming science results of AMiBA-13.« less

  9. Simulation and analyses of the aeroassist flight experiment attitude update method

    NASA Technical Reports Server (NTRS)

    Carpenter, J. R.

    1991-01-01

    A method which will be used to update the alignment of the Aeroassist Flight Experiment's Inertial Measuring Unit is simulated and analyzed. This method, the Star Line Maneuver, uses measurements from the Space Shuttle Orbiter star trackers along with an extended Kalman filter to estimate a correction to the attitude quaternion maintained by an Inertial Measuring Unit in the Orbiter's payload bay. This quaternion is corrupted by on-orbit bending of the Orbiter payload bay with respect to the Orbiter navigation base, which is incorporated into the payload quaternion when it is initialized via a direct transfer of the Orbiter attitude state. The method of updating this quaternion is examined through verification of baseline cases and Monte Carlo analysis using a simplified simulation, The simulation uses nominal state dynamics and measurement models from the Kalman filter as its real world models, and is programmed on Microvax minicomputer using Matlab, and interactive matrix analysis tool. Results are presented which confirm and augment previous performance studies, thereby enhancing confidence in the Star Line Maneuver design methodology.

  10. Modeling Nonlinear Errors in Surface Electromyography Due To Baseline Noise: A New Methodology

    PubMed Central

    Law, Laura Frey; Krishnan, Chandramouli; Avin, Keith

    2010-01-01

    The surface electromyographic (EMG) signal is often contaminated by some degree of baseline noise. It is customary for scientists to subtract baseline noise from the measured EMG signal prior to further analyses based on the assumption that baseline noise adds linearly to the observed EMG signal. The stochastic nature of both the baseline and EMG signal, however, may invalidate this assumption. Alternately, “true” EMG signals may be either minimally or nonlinearly affected by baseline noise. This information is particularly relevant at low contraction intensities when signal-to-noise ratios (SNR) may be lowest. Thus, the purpose of this simulation study was to investigate the influence of varying levels of baseline noise (approximately 2 – 40 % maximum EMG amplitude) on mean EMG burst amplitude and to assess the best means to account for signal noise. The simulations indicated baseline noise had minimal effects on mean EMG activity for maximum contractions, but increased nonlinearly with increasing noise levels and decreasing signal amplitudes. Thus, the simple baseline noise subtraction resulted in substantial error when estimating mean activity during low intensity EMG bursts. Conversely, correcting EMG signal as a nonlinear function of both baseline and measured signal amplitude provided highly accurate estimates of EMG amplitude. This novel nonlinear error modeling approach has potential implications for EMG signal processing, particularly when assessing co-activation of antagonist muscles or small amplitude contractions where the SNR can be low. PMID:20869716

  11. Intraoperative blood glucose management: impact of a real-time decision support system on adherence to institutional protocol.

    PubMed

    Nair, Bala G; Grunzweig, Katherine; Peterson, Gene N; Horibe, Mayumi; Neradilek, Moni B; Newman, Shu-Fang; Van Norman, Gail; Schwid, Howard A; Hao, Wei; Hirsch, Irl B; Patchen Dellinger, E

    2016-06-01

    Poor perioperative glycemic management can lead to negative surgical outcome. Improved compliance to glucose control protocol could lead to better glucose management. An Anesthesia Information Management System based decision support system-Smart Anesthesia Manager™ (SAM) was used to generate real-time reminders to the anesthesia providers to closely adhere to our institutional glucose management protocol. Compliance to hourly glucose measurements and correct insulin dose adjustments was compared for the baseline period (12 months) without SAM and the intervention period (12 months) with SAM decision support. Additionally, glucose management parameters were compared for the baseline and intervention periods. A total of 1587 cases during baseline and 1997 cases during intervention met the criteria for glucose management (diabetic patients or non-diabetic patients with glucose level >140 mg/dL). Among the intervention cases anesthesia providers chose to use SAM reminders 48.7 % of the time primarily for patients who had diabetes, higher HbA1C or body mass index, while disabling the system for the remaining cases. Compliance to hourly glucose measurement and correct insulin doses increased significantly during the intervention period when compared with the baseline (from 52.6 to 71.2 % and from 13.5 to 24.4 %, respectively). In spite of improved compliance to institutional protocol, the mean glucose levels and other glycemic management parameters did not show significant improvement with SAM reminders. Real-time electronic reminders improved intraoperative compliance to institutional glucose management protocol though glycemic parameters did not improve even when there was greater compliance to the protocol.

  12. Increasing employee awareness of the signs and symptoms of heart attack and the need to use 911 in a State Health Department.

    PubMed

    Fogle, Crystelle C; Oser, Carrie S; Blades, Lynda L; Harwell, Todd S; Helgerson, Steven D; Gohdes, Dorothy; Spence, Michael R; Dawson, Drew E

    2004-07-01

    Early recognition of the signs and symptoms of a heart attack can lead to reduced morbidity and mortality. A workplace intervention was conducted among 523 Montana state health department employees in 2003 to increase awareness of the signs and symptoms of heart attack and the need to use 911. All employees received an Act in Time to Heart Attack Signs brochure and wallet card with their paychecks. Act in Time posters were placed in key workplace areas. A weekly e-mail message, including a contest entry opportunity addressing the signs and symptoms of heart attack, was sent to all employees. Baseline and follow-up telephone surveys were conducted to evaluate intervention effectiveness. Awareness of heart attack signs and symptoms and the need to call 911 increased significantly among employees from baseline to follow-up: pain or discomfort in the jaw, neck, or back (awareness increased from 69% to 91%); feeling weak, light-headed, or faint (awareness increased from 79% to 89%); call 911 if someone is having a heart attack or stroke (awareness increased from 84% to 90%). Awareness of chest pain, pain or discomfort in the arms or shoulders, and shortness of breath were more than 90% at baseline and did not increase significantly at follow-up. At baseline, 69% of respondents correctly reported five or more of the signs and symptoms of heart attack; 89% reported correctly at follow-up. This low-cost workplace intervention increased awareness of the signs and symptoms of heart attack and the need to call 911.

  13. SHORT-TERM SAFETY PROFILE OF INTRAVITREAL ZIV-AFLIBERCEPT.

    PubMed

    Chhablani, Jay; Narayanan, Raja; Mathai, Annie; Yogi, Rohit; Stewart, Michael

    2016-06-01

    To evaluate the safety of intravitreal ziv-aflibercept (Zaltrap) in the treatment choroidal neovascularization secondary to age-related macular degeneration. Eligible eyes with choroidal neovascularization secondary to age-related macular degeneration each received a single intravitreal injection of ziv-aflibercept. Comprehensive ophthalmic examinations and detailed systemic evaluations were performed at baseline and Days 1, 7, and 30 after injection, and International Society for Clinical Electrophysiology of Vision standard electroretinography was performed at baseline and Day 30. Primary outcome measures were safety parameters that included signs of clinical and electroretinographic toxicity. Secondary outcome measures included changes in best-corrected visual acuity and central subfield thickness. Twelve eyes of 12 patients were treated. None of the patients complained of blurred vision, ocular pain, or bulbar injection at any of the follow-up visits, nor was intraocular inflammation noted. There were no significant differences in implicit times, "a" and "b" wave amplitudes, or b/a ratios at 1 month when compared with baseline (P = 0.4). None of the patients experienced serious ocular or systemic adverse events. Mean best-corrected visual acuity improved only slightly at 30 days (LogMAR 0.45 ± 0.31 [Snellen equivalent: 20/60]) compared with baseline (LogMAR 0.37 ± 0.24 [Snellen equivalent: 20/50]; P = 0.51). Single intravitreal injections of ziv-aflibercept into eyes with neovascular age-related macular degeneration appear to be safe through 1 month. Ziv-aflibercept could become a safe, low-cost therapy for macular diseases in developing countries and in those where intravitreal aflibercept (Eylea) is not available.

  14. Quantification of baseline pupillary response and task-evoked pupillary response during constant and incremental task load.

    PubMed

    Mosaly, Prithima R; Mazur, Lukasz M; Marks, Lawrence B

    2017-10-01

    The methods employed to quantify the baseline pupil size and task-evoked pupillary response (TEPR) may affect the overall study results. To test this hypothesis, the objective of this study was to assess variability in baseline pupil size and TEPR during two basic working memory tasks: constant load of 3-letters memorisation-recall (10 trials), and incremental load memorisation-recall (two trials of each load level), using two commonly used methods (1) change from trail/load specific baseline, (2) change from constant baseline. Results indicated that there was a significant shift in baseline between the trails for constant load, and between the load levels for incremental load. The TEPR was independent of shifts in baseline using method 1 only for constant load, and method 2 only for higher levels of incremental load condition. These important findings suggest that the assessment of both the baseline and methods to quantify TEPR are critical in ergonomics application, especially in studies with small number of trials per subject per condition. Practitioner Summary: Quantification of TEPR can be affected by shifts in baseline pupil size that are most likely affected by non-cognitive factors when other external factors are kept constant. Therefore, quantification methods employed to compute both baseline and TEPR are critical in understanding the information processing of humans in practical ergonomics settings.

  15. Assisting people with multiple disabilities actively correct abnormal standing posture with a Nintendo Wii balance board through controlling environmental stimulation.

    PubMed

    Shih, Ching-Hsiang; Shih, Ching-Tien; Chu, Chiung-Ling

    2010-01-01

    The latest researches adopted software technology turning the Nintendo Wii Balance Board into a high performance change of standing posture (CSP) detector, and assessed whether two persons with multiple disabilities would be able to control environmental stimulation using body swing (changing standing posture). This study extends Wii Balance Board functionality for standing posture correction (i.e., actively adjust abnormal standing posture) to assessed whether two persons with multiple disabilities would be able to actively correct their standing posture by controlling their favorite stimulation on/off using a Wii Balance Board with a newly developed standing posture correcting program (SPCP). The study was performed according to an ABAB design, in which A represented baseline and B represented intervention phases. Data showed that both participants significantly increased time duration of maintaining correct standing posture (TDMCSP) to activate the control system to produce environmental stimulation during the intervention phases. Practical and developmental implications of the findings were discussed.

  16. Improving nurses' knowledge of continuous ST-segment monitoring.

    PubMed

    Chronister, Connie

    2014-01-01

    Continuous ST-segment monitoring can result in detection of myocardial ischemia, but in clinical practice, continuous ST-segment monitoring is conducted incorrectly and underused by many registered nurses (RNs). Many RNs are unable to correctly institute ST-segment monitoring guidelines because of a lack of education. To evaluate whether an educational intervention, provided to 32 RNs, increases knowledge and correct clinical decision making (CDM) for the use of continuous ST-segment monitoring. At a single institution, an ST-segment monitoring class was provided to RNs in 2 cardiovascular units. Knowledge and correct CDM instruments were used for a baseline pretest and subsequent posttest after ST-segment monitoring education. Statistical significance between pretest and posttest scores for knowledge and correct CDM practice was noted with dependent t tests (P = .0001). Many RNs responsible for electrocardiographic monitoring are not aware of evidence-based ST-segment monitoring practice guidelines and cannot properly place precordial leads needed for ST-segment monitoring. Knowledge and correct CDM with ST-segment monitoring can be improved with focused education.

  17. Modeling The Hydrology And Water Allocation Under Climate Change In Rural River Basins: A Case Study From Nam Ngum River Basin, Laos

    NASA Astrophysics Data System (ADS)

    Jayasekera, D. L.; Kaluarachchi, J.; Kim, U.

    2011-12-01

    Rural river basins with sufficient water availability to maintain economic livelihoods can be affected with seasonal fluctuations of precipitation and sometimes by droughts. In addition, climate change impacts can also alter future water availability. General Circulation Models (GCMs) provide credible quantitative estimates of future climate conditions but such estimates are often characterized by bias and coarse scale resolution making it necessary to downscale the outputs for use in regional hydrologic models. This study develops a methodology to downscale and project future monthly precipitation in moderate scale basins where data are limited. A stochastic framework for single-site and multi-site generation of weekly rainfall is developed while preserving the historical temporal and spatial correlation structures. The spatial correlations in the simulated occurrences and the amounts are induced using spatially correlated yet serially independent random numbers. This method is applied to generate weekly precipitation data for a 100-year period in the Nam Ngum River Basin (NNRB) that has a land area of 16,780 km2 located in Lao P.D.R. This method is developed and applied using precipitation data from 1961 to 2000 for 10 selected weather stations that represents the basin rainfall characteristics. Bias-correction method, based on fitted theoretical probability distribution transformations, is applied to improve monthly mean frequency, intensity and the amount of raw GCM precipitation predicted at a given weather station using CGCM3.1 and ECHAM5 for SRES A2 emission scenario. Bias-correction procedure adjusts GCM precipitation to approximate the long-term frequency and the intensity distribution observed at a given weather station. Index of agreement and mean absolute error are determined to assess the overall ability and performance of the bias correction method. The generated precipitation series aggregated at monthly time step was perturbed by the change factors estimated using the corrected GCM and baseline scenarios for future time periods of 2011-2050 and 2051-2090. A network based hydrologic and water resources model, WEAP, was used to simulate the current water allocation and management practices to identify the impacts of climate change in the 20th century. The results of this work are used to identify the multiple challenges faced by stakeholders and planners in water allocation for competing demands in the presence of climate change impacts.

  18. Comparing spatially static and dynamic vibrotactile take-over requests in the driver seat.

    PubMed

    Petermeijer, S M; Cieler, S; de Winter, J C F

    2017-02-01

    Vibrotactile stimuli can be effective as warning signals, but their effectiveness as directional take-over requests in automated driving is yet unknown. This study aimed to investigate the correct response rate, reaction times, and eye and head orientation for static versus dynamic directional take-over requests presented via vibrating motors in the driver seat. In a driving simulator, eighteen participants performed three sessions: 1) a session involving no driving (Baseline), 2) driving a highly automated car without additional task (HAD), and 3) driving a highly automated car while performing a mentally demanding task (N-Back). Per session, participants received four directional static (in the left or right part of the seat) and four dynamic (moving from one side towards the opposite left or right of the seat) take-over requests via two 6×4 motor matrices embedded in the seat back and bottom. In the Baseline condition, participants reported whether the cue was left or right, and in the HAD and N-Back conditions participants had to change lanes to the left or to the right according to the directional cue. The correct response rate was operationalized as the accuracy of the self-reported direction (Baseline session) and the accuracy of the lane change direction (HAD & N-Back sessions). The results showed that the correct response rate ranged between 94% for static patterns in the Baseline session and 74% for dynamic patterns in the N-Back session, although these effects were not statistically significant. Steering wheel touch and steering input reaction times were approximately 200ms faster for static patterns than for dynamic ones. Eye tracking results revealed a correspondence between head/eye-gaze direction and lane change direction, and showed that head and eye-gaze movements where initiated faster for static vibrations than for dynamic ones. In conclusion, vibrotactile stimuli presented via the driver seat are effective as warnings, but their effectiveness as directional take-over requests may be limited. The present study may encourage further investigation into how to get drivers safely back into the loop. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Efficacy and safety of dapagliflozin in addition to insulin therapy in Japanese patients with type 2 diabetes: Results of the interim analysis of 16-week double-blind treatment period.

    PubMed

    Araki, Eiichi; Onishi, Yukiko; Asano, Michiko; Kim, Hyosung; Ekholm, Ella; Johnsson, Eva; Yajima, Toshitaka

    2016-07-01

    Dapagliflozin treatment when added to insulin therapy in Japanese patients with type 2 diabetes remains to be evaluated. This was a multicenter, randomized, double-blind, parallel-group, placebo-controlled study to evaluate efficacy (at 16 weeks) and long-term safety (at 52 weeks) of dapagliflozin in addition to insulin therapy. The interim analysis was carried out at week 16 to assess the efficacy and safety profiles. The patients receiving insulin (n = 182) were randomized to either dapagliflozin 5 mg or a placebo at a 2:1 ratio. The primary efficacy end-point was the change in hemoglobin A1c (HbA1c) from baseline at week 16. Patients in the dapagliflozin group showed an adjusted decrease in HbA1c of -0.55% from baseline, whereas the placebo showed a marginal increase of 0.05%. The placebo-corrected mean change of HbA1c from baseline to week 16 in dapagliflozin was -0.60% (P < 0.0001). In addition, the placebo-corrected mean change of fasting plasma glucose and bodyweight from baseline to week 16 in the dapagliflozin group was -22.7 mg/dL (P < 0.0001) and -1.21 kg (P < 0.0001), respectively. The placebo-corrected mean daily insulin dose in the dapagliflozin group was numerically decreased (treatment difference: -0.72 IU/day; P = 0.0743). No major episodes or discontinuations as a result of hypoglycemia were reported during the study period. Dapagliflozin used as add-on treatment to insulin therapy showed significantly greater reduction of HbA1c, fasting plasma glucose and bodyweight without severe hypoglycemia compared with the placebo at week 16. These results show the clinical benefit of prescribing dapagliflozin for Japanese patients with insufficient glycemic control even with insulin therapy. © 2015 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  20. Blood gases, biochemistry, and hematology of Galapagos green turtles (Chelonia mydas).

    PubMed

    Lewbart, Gregory A; Hirschfeld, Maximilian; Denkinger, Judith; Vasco, Karla; Guevara, Nataly; García, Juan; Muñoz, Juanpablo; Lohmann, Kenneth J

    2014-01-01

    The green turtle, Chelonia mydas, is an endangered marine chelonian with a circum-global distribution. Reference blood parameter intervals have been published for some chelonian species, but baseline hematology, biochemical, and blood gas values are lacking from the Galapagos sea turtles. Analyses were done on blood samples drawn from 28 green turtles captured in two foraging locations on San Cristóbal Island (14 from each site). Of these turtles, 20 were immature and of unknown sex; the other eight were males (five mature, three immature). A portable blood analyzer (iSTAT) was used to obtain near immediate field results for pH, lactate, pO2, pCO2, HCO3-, Hct, Hb, Na, K, iCa, and Glu. Parameter values affected by temperature were corrected in two ways: (1) with standard formulas; and (2) with auto-corrections made by the iSTAT. The two methods yielded clinically equivalent results. Standard laboratory hematology techniques were employed for the red and white blood cell counts and the hematocrit determination, which was also compared to the hematocrit values generated by the iSTAT. Of all blood analytes, only lactate concentrations were positively correlated with body size. All other values showed no significant difference between the two sample locations nor were they correlated with body size or internal temperature. For hematocrit count, the iSTAT blood analyzer yielded results indistinguishable from those obtained with high-speed centrifugation. The values reported in this study provide baseline data that may be useful in comparisons among populations and in detecting changes in health status among Galapagos sea turtles. The findings might also be helpful in future efforts to demonstrate associations between specific biochemical parameters and disease.

  1. Blood Gases, Biochemistry, and Hematology of Galapagos Green Turtles (Chelonia Mydas)

    PubMed Central

    Lewbart, Gregory A.; Hirschfeld, Maximilian; Denkinger, Judith; Vasco, Karla; Guevara, Nataly; García, Juan; Muñoz, Juanpablo; Lohmann, Kenneth J.

    2014-01-01

    The green turtle, Chelonia mydas, is an endangered marine chelonian with a circum-global distribution. Reference blood parameter intervals have been published for some chelonian species, but baseline hematology, biochemical, and blood gas values are lacking from the Galapagos sea turtles. Analyses were done on blood samples drawn from 28 green turtles captured in two foraging locations on San Cristóbal Island (14 from each site). Of these turtles, 20 were immature and of unknown sex; the other eight were males (five mature, three immature). A portable blood analyzer (iSTAT) was used to obtain near immediate field results for pH, lactate, pO2, pCO2, HCO3 −, Hct, Hb, Na, K, iCa, and Glu. Parameter values affected by temperature were corrected in two ways: (1) with standard formulas; and (2) with auto-corrections made by the iSTAT. The two methods yielded clinically equivalent results. Standard laboratory hematology techniques were employed for the red and white blood cell counts and the hematocrit determination, which was also compared to the hematocrit values generated by the iSTAT. Of all blood analytes, only lactate concentrations were positively correlated with body size. All other values showed no significant difference between the two sample locations nor were they correlated with body size or internal temperature. For hematocrit count, the iSTAT blood analyzer yielded results indistinguishable from those obtained with high-speed centrifugation. The values reported in this study provide baseline data that may be useful in comparisons among populations and in detecting changes in health status among Galapagos sea turtles. The findings might also be helpful in future efforts to demonstrate associations between specific biochemical parameters and disease. PMID:24824065

  2. Mathematical Modeling of Serum 13C-Retinol in Captive Rhesus Monkeys Provides New Insights on Hypervitaminosis A1–3

    PubMed Central

    Escaron, Anne L.; Green, Michael H.; Howe, Julie A.; Tanumihardjo, Sherry A.

    2009-01-01

    Hypervitaminosis A is increasingly a public health concern, and thus noninvasive quantitative methods merit exploration. In this study, we applied the 13C-retinol isotope dilution test to a nonhuman primate model with excessive liver stores. After baseline serum chemistries, rhesus macaques (Macaca mulatta; n = 16) were administered 3.5 μmol 13C2-retinyl acetate. Blood was drawn at baseline, 5 h, and 2, 4, 7, 14, 21, and 28 d following the dose. Liver biopsies were collected 7 d before and 2 d after dosing (n = 4) and at 7, 14, and 28 d (n = 4/time) after dosing. Serum and liver were analyzed by HPLC and GC-combustion-isotope ratio MS for retinol and its enrichment, respectively. Model-based compartmental analysis was applied to serum data. Lactate dehydrogenase was elevated in 50% of the monkeys. Total body reserves (TBR) of vitamin A (VA) were calculated at 28 d. Predicted TBR (3.52 ± 2.01 mmol VA) represented measured liver stores (4.56 ± 1.38 mmol VA; P = 0.124). Predicted liver VA concentrations (13.3 ± 9.7 μmol/g) were similar to measured liver VA concentrations (16.4 ± 5.3 μmol/g). The kinetic models predict that 27–52% of extravascular VA is exchanging with serum in hypervitaminotic A monkeys. The test correctly diagnosed hypervitaminosis A in all monkeys, i.e. 100% sensitivity. Stable isotope techniques have important public health potential for the classification of VA status, including hypervitaminosis, because no other technique besides invasive liver biopsies, correctly identifies excessive liver VA stores. PMID:19710158

  3. Some direct and generalized effects of replacing an autistic man's echolalia with correct responses to questions.

    PubMed

    McMorrow, M J; Foxx, R M

    1986-01-01

    We extended the use of operant procedures to decrease immediate echolalia and increase the appropriate responding to questions of a 21-year-old autistic man. Three experiments were conducted in which the overall plan was to encourage the subject to remain quiet before, during, and after the presentation of questions and teach him to use environmental cues (i.e., word cards or a model's responses) to increase the likelihood of responding correctly. Multiple baseline designs demonstrated that echolalia was rapidly replaced with correct stimulus-specific responses. In addition, there were a variety of generalized improvements in the subject's verbal responses to questions. The procedures and results are contrasted to previous research in an attempt to explain the encouraging findings.

  4. Crustal Deformation along San Andreas Fault System revealed by GPS and Sentinel-1 InSAR

    NASA Astrophysics Data System (ADS)

    Xu, X.; Sandwell, D. T.

    2017-12-01

    We present a crustal deformation velocity map along the San Andreas Fault System by combining measurements from Sentinel-1 Interferometric Synthetic Aperture Radar (InSAR) and Global Positioning System (GPS) velocity models (CGM V1). We assembled 5 tracks of descending Sentinel-1 InSAR data spanning 2014.11-2017.02, and produced 545 interferograms, each of which covers roughly 250km x 420km area ( 60 bursts). These interferograms are unwrapped using SNAPHU [Chen & Zebker, 2002], with the 2Npi unwrapping ambiguity corrected with a sparse recovery method. We used coherence-based small baseline subset (SBAS) method [Tong & Schmidt, 2016] together with atmospheric correction by common-point stacking [Tymofyeyeva and Fialko, 2015] to construct deformation time series [Xu et. al., 2017]. Then we project the horizontal GPS model and vertical GPS data into satellite line-of-sight directions separately. We first remove the horizontal GPS model from InSAR measurements and perform elevation-dependent atmospheric phase correction. Then we compute the discrepancy between the remaining InSAR measurements and vertical GPS data. We interpolate this discrepancy and remove it from the residual InSAR measurements. Finally, we restore the horizontal GPS model. Preliminary results show that fault creep over the San Jacinto fault, the Elsinore fault, and the San Andreas creeping section is clearly resolved. During the period of drought, the Central Valley of California was subsiding at a high rate (up to 40 cm/yr), while the city of San Jose is uplifting due to recharge, with a quaternary fault acting as a ground water barrier. These findings will be reported during the meeting.

  5. Increased Muscle Sympathetic Nerve Activity and Impaired Executive Performance Capacity in Obstructive Sleep Apnea

    PubMed Central

    Goya, Thiago T.; Silva, Rosyvaldo F.; Guerra, Renan S.; Lima, Marta F.; Barbosa, Eline R.F.; Cunha, Paulo Jannuzzi; Lobo, Denise M.L.; Buchpiguel, Carlos A.; Busatto-Filho, Geraldo; Negrão, Carlos E.; Lorenzi-Filho, Geraldo; Ueno-Pardi, Linda M.

    2016-01-01

    Study Objectives: To investigate muscle sympathetic nerve activity (MSNA) response and executive performance during mental stress in obstructive sleep apnea (OSA). Methods: Individuals with no other comorbidities (age = 52 ± 1 y, body mass index = 29 ± 0.4, kg/m2) were divided into two groups: (1) control (n = 15) and (2) untreated OSA (n = 20) defined by polysomnography. Mini-Mental State of Examination (MMSE) and Inteligence quocient (IQ) were assessed. Heart rate (HR), blood pressure (BP), and MSNA (microneurography) were measured at baseline and during 3 min of the Stroop Color Word Test (SCWT). Sustained attention and inhibitory control were assessed by the number of correct answers and errors during SCWT. Results: Control and OSA groups (apnea-hypopnea index, AHI = 8 ± 1 and 47 ± 1 events/h, respectively) were similar in age, MMSE, and IQ. Baseline HR and BP were similar and increased similarly during SCWT in control and OSA groups. In contrast, baseline MSNA was higher in OSA compared to controls. Moreover, MSNA significantly increased in the third minute of SCWT in OSA, but remained unchanged in controls (P < 0.05). The number of correct answers was lower and the number of errors was significantly higher during the second and third minutes of SCWT in the OSA group (P < 0.05). There was a significant correlation (P < 0.01) between the number of errors in the third minute of SCWT with AHI (r = 0.59), arousal index (r = 0.55), and minimum O2 saturation (r = −0.57). Conclusions: As compared to controls, MSNA is increased in patients with OSA at rest, and further significant MSNA increments and worse executive performance are seen during mental stress. Clinical Trial Registration: URL: http://www.clinicaltrials.gov, registration number: NCT002289625. Citation: Goya TT, Silva RF, Guerra RS, Lima MF, Barbosa ER, Cunha PJ, Lobo DM, Buchpiguel CA, Busatto-Filho G, Negrão CE, Lorenzi-Filho G, Ueno-Pardi LM. Increased muscle sympathetic nerve activity and impaired executive performance capacity in obstructive sleep apnea. SLEEP 2016;39(1):25–33. PMID:26237773

  6. Measures of total stress-induced blood pressure responses are associated with vascular damage.

    PubMed

    Nazzaro, Pietro; Seccia, Teresa; Vulpis, Vito; Schirosi, Gabriella; Serio, Gabriella; Battista, Loredana; Pirrelli, Anna

    2005-09-01

    The role of cardiovascular reactivity to study hypertension, and the assessment methods, are still controversial. We aimed to verify the association of hypertension and vascular damage with several measures of cardiovascular response. We studied 40 patients with normal-high (132 +/- 1/87 +/- 1 mm Hg) blood pressure (Group 1) and 80 untreated hypertensive subjects. Postischemic forearm vascular resistance (mFVR) served to differentiate hypertensive subjects (142 +/- 2/92 +/- 1 mm Hg v 143 +/- 2/94 +/- 2 mm Hg, P = NS) with a lower (Group 2) and higher (Group 3) hemodynamic index of vascular damage (4.8 +/- .05 v 6.3 +/- .09, P < .001). Reactivity was induced by Stroop (5') and cold pressor (90") tests. We measured muscular contraction and skin conductance as indices of emotional arousal, blood pressure, heart rate, forearm blood flow, and vascular resistance. Reactivity measures included: a) change from baseline, b) residualized score, c) cumulative change from baseline and residualized score, and d) total reactivity as area-under-the-curve (AUC), including changes occurring during baseline and recovery phases. The AUC of systolic blood pressure, diastolic blood pressure, and mFVR progressively increased in the groups (P < .001). Corrections of anthropometric and metabolic confounders were introduced in the Pearson equation between mFVR and reactivity measures. The AUC of SBP, DBP, and forearm blood flow and resistance demonstrated the highest (P < .001) correlation. On multiple regression analysis, AUC of SBP (beta = 0.634) and forearm blood flow (beta = -0.337) were predictive (P < .001) of vascular damage. Total blood pressure stress response, as AUC, including baseline and recovery phases, was significantly better associated with hypertension and vascular damage than the other reactivity measures studied.

  7. Pharmacokinetics and C-Reactive Protein Modelling of Anti-IL-6 Antibody (PF-04236921) in Healthy Volunteers and Patients with Autoimmune Disease.

    PubMed

    Li, Cheryl; Shoji, Satoshi; Beebe, Jean

    2018-05-18

    The purpose of this study was to characterize pharmacokinetics (PK) of PF-04236921, a novel anti-IL-6 monoclonal antibody, and its pharmacokinetics/pharmacodynamics (PK/PD) relationship on serum C-Reactive Protein (CRP) in healthy volunteers and patients with rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and Crohn's disease (CD) METHODS: Population modelling analyses were conducted using nonlinear mixed effects modelling. Data from 2 phase 1 healthy volunteer studies, a phase 1 RA study, a Phase 2 CD study, and a Phase 2 SLE study were included. A 2-compartment model with first order absorption and linear elimination and a mechanism-based indirect response model adequately described the PK and PK/PD relationships, respectively. Central compartment volume of distribution (Vc) positively correlated with body weight. Clearance (CL) negatively correlated with baseline albumin concentration and positively correlated with baseline CRP and creatinine clearance, and was slightly lower in females. After correcting for covariates, CL in CD subjects was approximately 60% higher than other populations. Maximum inhibition of PF-04236921 on CRP production (I max ) negatively correlated with baseline albumin. I max positively correlated with baseline CRP and the relationship was captured as a covariance structure in the PK/PD model. Integrated population PK and PK/PD models of PF-04236921 have been developed using pooled data from healthy subjects and autoimmune patients. The current model enables simulation of PF-04236921 PK and PD profiles under various dosing regimens and patient populations and should facilitate future clinical study of PF-04236921 and other anti-IL6 monoclonal antibodies. This article is protected by copyright. All rights reserved.

  8. Erratum to: Measurement of the inclusive jet cross-section in proton-proton collisions at $$ \\sqrt{s}=7 $$ TeV using 4.5 fb -1 of data with the ATLAS detector

    DOE PAGES

    Aad, G.; Abbott, B.; Abdallah, J.; ...

    2015-09-01

    It was found that the non-perturbative corrections calculated using Pythia with the Perugia 2011 tune did not include the effect of the underlying event. The affected correction factors were recomputed using the Pythia 6.427 generator. These corrections are applied as baseline to the NLO pQCD calculations and thus the central values of the theoretical predictions have changed by a few percent with the new corrections. This has a minor impact on the agreement between the data and the theoretical predictions. Figures 2 and 6 to 13, and all the tables have been updated with the new values. A few sentencesmore » in the discussion in sections 5.2 and 9 were altered or removed.[Figure not available: see fulltext.]« less

  9. Erratum: Erratum to: Measurement of the inclusive jet cross-section in proton-proton collisions at √{s}=7 TeV using 4.5 fb-1 of data with the ATLAS detector

    NASA Astrophysics Data System (ADS)

    Aad, G.; Abbott, B.; Abdallah, J.; Abdel Khalek, S.; Abdinov, O.; Aben, R.; Abi, B.; Abolins, M.; AbouZeid, O. S.; Abramowicz, H.; Abreu, H.; Abreu, R.; Abulaiti, Y.; Acharya, B. S.; Adamczyk, L.; Adams, D. L.; Adelman, J.; Adomeit, S.; Adye, T.; Agatonovic-Jovin, T.; Aguilar-Saavedra, J. A.; Agustoni, M.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akerstedt, H.; Åkesson, T. P. A.; Akimoto, G.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albrand, S.; Alconada Verzini, M. J.; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexandre, G.; Alexopoulos, T.; Alhroob, M.; Alimonti, G.; Alio, L.; Alison, J.; Allbrooke, B. M. M.; Allison, L. J.; Allport, P. P.; Almond, J.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Altheimer, A.; Alvarez Gonzalez, B.; Alviggi, M. G.; Amako, K.; Amaral Coutinho, Y.; Amelung, C.; Amidei, D.; Amor Dos Santos, S. P.; Amorim, A.; Amoroso, S.; Amram, N.; Amundsen, G.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, G.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Anduaga, X. S.; Angelidakis, S.; Angelozzi, I.; Anger, P.; Angerami, A.; Anghinolfi, F.; Anisenkov, A. V.; Anjos, N.; Annovi, A.; Antonaki, A.; Antonelli, M.; Antonov, A.; Antos, J.; Anulli, F.; Aoki, M.; Aperio Bella, L.; Apolle, R.; Arabidze, G.; Aracena, I.; Arai, Y.; Araque, J. P.; Arce, A. T. H.; Arguin, J.-F.; Argyropoulos, S.; Arik, M.; Armbruster, A. J.; Arnaez, O.; Arnal, V.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Asai, S.; Asbah, N.; Ashkenazi, A.; Åsman, B.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkinson, M.; Atlay, N. B.; Auerbach, B.; Augsten, K.; Aurousseau, M.; Avolio, G.; Azuelos, G.; Azuma, Y.; Baak, M. A.; Baas, A.; Bacci, C.; Bachacou, H.; Bachas, K.; Backes, M.; Backhaus, M.; Backus Mayes, J.; Badescu, E.; Bagiacchi, P.; Bagnaia, P.; Bai, Y.; Bain, T.; Baines, J. T.; Baker, O. K.; Balek, P.; Balli, F.; Banas, E.; Banerjee, Sw.; Bannoura, A. A. E.; Bansal, V.; Bansil, H. S.; Barak, L.; Baranov, S. P.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barisonzi, M.; Barklow, T.; Barlow, N.; Barnett, B. M.; Barnett, R. M.; Barnovska, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Barreiro, F.; Barreiro Guimarães da Costa, J.; Bartoldus, R.; Barton, A. E.; Bartos, P.; Bartsch, V.; Bassalat, A.; Basye, A.; Bates, R. L.; Batley, J. R.; Battaglia, M.; Battistin, M.; Bauer, F.; Bawa, H. S.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Beccherle, R.; Bechtle, P.; Beck, H. P.; Becker, K.; Becker, S.; Beckingham, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bedikian, S.; Bednyakov, V. A.; Bee, C. P.; Beemster, L. J.; Beermann, T. A.; Begel, M.; Behr, K.; Belanger-Champagne, C.; Bell, P. J.; Bell, W. H.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Beltramello, O.; Benary, O.; Benchekroun, D.; Bendtz, K.; Benekos, N.; Benhammou, Y.; Benhar Noccioli, E.; Benitez Garcia, J. A.; Benjamin, D. P.; Bensinger, J. R.; Benslama, K.; Bentvelsen, S.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Berghaus, F.; Beringer, J.; Bernard, C.; Bernat, P.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertolucci, F.; Bertsche, C.; Bertsche, D.; Besana, M. I.; Besjes, G. J.; Bessidskaia Bylund, O.; Bessner, M.; Besson, N.; Betancourt, C.; Bethke, S.; Bhimji, W.; Bianchi, R. M.; Bianchini, L.; Bianco, M.; Biebel, O.; Bieniek, S. P.; Bierwagen, K.; Biesiada, J.; Biglietti, M.; Bilbao De Mendizabal, J.; Bilokon, H.; Bindi, M.; Binet, S.; Bingul, A.; Bini, C.; Black, C. W.; Black, J. E.; Black, K. M.; Blackburn, D.; Blair, R. E.; Blanchard, J.-B.; Blazek, T.; Bloch, I.; Blocker, C.; Blum, W.; Blumenschein, U.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boddy, C. R.; Boehler, M.; Boek, T. T.; Bogaerts, J. A.; Bogdanchikov, A. G.; Bogouch, A.; Bohm, C.; Bohm, J.; Boisvert, V.; Bold, T.; Boldea, V.; Boldyrev, A. S.; Bomben, M.; Bona, M.; Boonekamp, M.; Borisov, A.; Borissov, G.; Borri, M.; Borroni, S.; Bortfeldt, J.; Bortolotto, V.; Bos, K.; Boscherini, D.; Bosman, M.; Boterenbrood, H.; Boudreau, J.; Bouffard, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Bousson, N.; Boutouil, S.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Bratzler, U.; Brau, B.; Brau, J. E.; Braun, H. M.; Brazzale, S. F.; Brelier, B.; Brendlinger, K.; Brennan, A. J.; Brenner, R.; Bressler, S.; Bristow, K.; Bristow, T. M.; Britton, D.; Brochu, F. M.; Brock, I.; Brock, R.; Bromberg, C.; Bronner, J.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brosamer, J.; Brost, E.; Brown, J.; Bruckman de Renstrom, P. A.; Bruncko, D.; Bruneliere, R.; Brunet, S.; Bruni, A.; Bruni, G.; Bruschi, M.; Bryngemark, L.; Buanes, T.; Buat, Q.; Bucci, F.; Buchholz, P.; Buckingham, R. M.; Buckley, A. G.; Buda, S. I.; Budagov, I. A.; Buehrer, F.; Bugge, L.; Bugge, M. K.; Bulekov, O.; Bundock, A. C.; Burckhart, H.; Burdin, S.; Burghgrave, B.; Burke, S.; Burmeister, I.; Busato, E.; Büscher, D.; Büscher, V.; Bussey, P.; Buszello, C. P.; Butler, B.; Butler, J. M.; Butt, A. I.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Byszewski, M.; Cabrera Urbán, S.; Caforio, D.; Cakir, O.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Calkins, R.; Caloba, L. P.; Calvet, D.; Calvet, S.; Camacho Toro, R.; Camarda, S.; Cameron, D.; Caminada, L. M.; Caminal Armadans, R.; Campana, S.; Campanelli, M.; Campoverde, A.; Canale, V.; Canepa, A.; Cano Bret, M.; Cantero, J.; Cantrill, R.; Cao, T.; Capeans Garrido, M. D. M.; Caprini, I.; Caprini, M.; Capua, M.; Caputo, R.; Cardarelli, R.; Carli, T.; Carlino, G.; Carminati, L.; Caron, S.; Carquin, E.; Carrillo-Montoya, G. D.; Carter, J. R.; Carvalho, J.; Casadei, D.; Casado, M. P.; Casolino, M.; Castaneda-Miranda, E.; Castelli, A.; Castillo Gimenez, V.; Castro, N. F.; Catastini, P.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Cattani, G.; Cavaliere, V.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Ceradini, F.; Cerio, B.; Cerny, K.; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cerv, M.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chalupkova, I.; Chang, P.; Chapleau, B.; Chapman, J. D.; Charfeddine, D.; Charlton, D. G.; Chau, C. C.; Chavez Barajas, C. A.; Cheatham, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, H.; Chen, K.; Chen, L.; Chen, S.; Chen, X.; Chen, Y.; Chen, Y.; Cheng, H. C.; Cheng, Y.; Cheplakov, A.; Cherkaoui El Moursli, R.; Chernyatin, V.; Cheu, E.; Chevalier, L.; Chiarella, V.; Chiefari, G.; Childers, J. T.; Chilingarov, A.; Chiodini, G.; Chisholm, A. S.; Chislett, R. T.; Chitan, A.; Chizhov, M. V.; Chouridou, S.; Chow, B. K. B.; Chromek-Burckhart, D.; Chu, M. L.; Chudoba, J.; Chwastowski, J. J.; Chytka, L.; Ciapetti, G.; Ciftci, A. K.; Ciftci, R.; Cinca, D.; Cindro, V.; Ciocio, A.; Cirkovic, P.; Citron, Z. H.; Citterio, M.; Ciubancan, M.; Clark, A.; Clark, P. J.; Clarke, R. N.; Cleland, W.; Clemens, J. C.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Coffey, L.; Cogan, J. G.; Coggeshall, J.; Cole, B.; Cole, S.; Colijn, A. P.; Collot, J.; Colombo, T.; Colon, G.; Compostella, G.; Conde Muiño, P.; Coniavitis, E.; Conidi, M. C.; Connell, S. H.; Connelly, I. A.; Consonni, S. M.; Consorti, V.; Constantinescu, S.; Conta, C.; Conti, G.; Conventi, F.; Cooke, M.; Cooper, B. D.; Cooper-Sarkar, A. M.; Cooper-Smith, N. J.; Copic, K.; Cornelissen, T.; Corradi, M.; Corriveau, F.; Corso-Radu, A.; Cortes-Gonzalez, A.; Cortiana, G.; Costa, G.; Costa, M. J.; Costanzo, D.; Côté, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cribbs, W. A.; Crispin Ortuzar, M.; Cristinziani, M.; Croft, V.; Crosetti, G.; Cuciuc, C.-M.; Cuhadar Donszelmann, T.; Cummings, J.; Curatolo, M.; Cuthbert, C.; Czirr, H.; Czodrowski, P.; Czyczula, Z.; D'Auria, S.; D'Onofrio, M.; Da Cunha Sargedas De Sousa, M. J.; Da Via, C.; Dabrowski, W.; Dafinca, A.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Daniells, A. C.; Dano Hoffmann, M.; Dao, V.; Darbo, G.; Darmora, S.; Dassoulas, J. A.; Dattagupta, A.; Davey, W.; David, C.; Davidek, T.; Davies, E.; Davies, M.; Davignon, O.; Davison, A. R.; Davison, P.; Davygora, Y.; Dawe, E.; Dawson, I.; Daya-Ishmukhametova, R. K.; De, K.; de Asmundis, R.; De Castro, S.; De Cecco, S.; De Groot, N.; de Jong, P.; De la Torre, H.; De Lorenzi, F.; De Nooij, L.; De Pedis, D.; De Salvo, A.; De Sanctis, U.; De Santo, A.; De Vivie De Regie, J. B.; Dearnaley, W. J.; Debbe, R.; Debenedetti, C.; Dechenaux, B.; Dedovich, D. V.; Deigaard, I.; Del Peso, J.; Del Prete, T.; Deliot, F.; Delitzsch, C. M.; Deliyergiyev, M.; Dell'Acqua, A.; Dell'Asta, L.; Dell'Orso, M.; Della Pietra, M.; della Volpe, D.; Delmastro, M.; Delsart, P. A.; Deluca, C.; Demers, S.; Demichev, M.; Demilly, A.; Denisov, S. P.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; Di Ciaccio, A.; Di Ciaccio, L.; Di Domenico, A.; Di Donato, C.; Di Girolamo, A.; Di Girolamo, B.; Di Mattia, A.; Di Micco, B.; Di Nardo, R.; Di Simone, A.; Di Sipio, R.; Di Valentino, D.; Dias, F. A.; Diaz, M. A.; Diehl, E. B.; Dietrich, J.; Dietzsch, T. A.; Diglio, S.; Dimitrievska, A.; Dingfelder, J.; Dionisi, C.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; do Vale, M. A. B.; Do Valle Wemans, A.; Dobos, D.; Doglioni, C.; Doherty, T.; Dohmae, T.; Dolejsi, J.; Dolezal, Z.; Dolgoshein, B. A.; Donadelli, M.; Donati, S.; Dondero, P.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Dris, M.; Dubbert, J.; Dube, S.; Dubreuil, E.; Duchovni, E.; Duckeck, G.; Ducu, O. A.; Duda, D.; Dudarev, A.; Dudziak, F.; Duflot, L.; Duguid, L.; Dührssen, M.; Dunford, M.; Duran Yildiz, H.; Düren, M.; Durglishvili, A.; Dwuznik, M.; Dyndal, M.; Ebke, J.; Edson, W.; Edwards, N. C.; Ehrenfeld, W.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; El Kacimi, M.; Ellert, M.; Elles, S.; Ellinghaus, F.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Endner, O. C.; Endo, M.; Engelmann, R.; Erdmann, J.; Ereditato, A.; Eriksson, D.; Ernis, G.; Ernst, J.; Ernst, M.; Ernwein, J.; Errede, D.; Errede, S.; Ertel, E.; Escalier, M.; Esch, H.; Escobar, C.; Esposito, B.; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Fabbri, L.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Falla, R. J.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Favareto, A.; Fayard, L.; Federic, P.; Fedin, O. L.; Fedorko, W.; Fehling-Kaschek, M.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Feng, H.; Fenyuk, A. B.; Fernandez Perez, S.; Ferrag, S.; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; Ferreira de Lima, D. E.; Ferrer, A.; Ferrere, D.; Ferretti, C.; Ferretto Parodi, A.; Fiascaris, M.; Fiedler, F.; Filipčič, A.; Filipuzzi, M.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Firan, A.; Fischer, A.; Fischer, J.; Fisher, W. C.; Fitzgerald, E. A.; Flechl, M.; Fleck, I.; Fleischmann, P.; Fleischmann, S.; Fletcher, G. T.; Fletcher, G.; Flick, T.; Floderus, A.; Flores Castillo, L. R.; Florez Bustos, A. C.; Flowerdew, M. J.; Formica, A.; Forti, A.; Fortin, D.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Franchino, S.; Francis, D.; Franconi, L.; Franklin, M.; Franz, S.; Fraternali, M.; French, S. T.; Friedrich, C.; Friedrich, F.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Fullana Torregrosa, E.; Fulsom, B. G.; Fuster, J.; Gabaldon, C.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, P.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallo, V.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Gao, J.; Gao, Y. S.; Garay Walls, F. M.; Garberson, F.; García, C.; García Navarro, J. E.; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Gatti, C.; Gaudio, G.; Gaur, B.; Gauthier, L.; Gauzzi, P.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Ge, P.; Gecse, Z.; Gee, C. N. P.; Geerts, D. A. A.; Geich-Gimbel, Ch.; Gellerstedt, K.; Gemme, C.; Gemmell, A.; Genest, M. H.; Gentile, S.; George, M.; George, S.; Gerbaudo, D.; Gershon, A.; Ghazlane, H.; Ghodbane, N.; Giacobbe, B.; Giagu, S.; Giangiobbe, V.; Giannetti, P.; Gianotti, F.; Gibbard, B.; Gibson, S. M.; Gilchriese, M.; Gillam, T. P. S.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giokaris, N.; Giordani, M. P.; Giordano, R.; Giorgi, F. M.; Giorgi, F. M.; Giraud, P. F.; Giugni, D.; Giuliani, C.; Giulini, M.; Gjelsten, B. K.; Gkaitatzis, S.; Gkialas, I.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Glonti, G. L.; Goblirsch-Kolb, M.; Goddard, J. R.; Godlewski, J.; Goeringer, C.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gomez Fajardo, L. S.; Gonçalo, R.; Goncalves Pinto Firmino Da Costa, J.; Gonella, L.; González de la Hoz, S.; Gonzalez Parra, G.; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorelov, I.; Gorini, B.; Gorini, E.; Gorišek, A.; Gornicki, E.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Gouighri, M.; Goujdami, D.; Goulette, M. P.; Goussiou, A. G.; Goy, C.; Gozpinar, S.; Grabas, H. M. X.; Graber, L.; Grabowska-Bold, I.; Grafström, P.; Grahn, K.-J.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Grassi, V.; Gratchev, V.; Gray, H. M.; Graziani, E.; Grebenyuk, O. G.; Greenwood, Z. D.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grishkevich, Y. V.; Grivaz, J.-F.; Grohs, J. P.; Grohsjean, A.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Groth-Jensen, J.; Grout, Z. J.; Guan, L.; Guescini, F.; Guest, D.; Gueta, O.; Guicheney, C.; Guido, E.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Gunther, J.; Guo, J.; Gupta, S.; Gutierrez, P.; Gutierrez Ortiz, N. G.; Gutschow, C.; Guttman, N.; Guyot, C.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Haefner, P.; Hageböck, S.; Hajduk, Z.; Hakobyan, H.; Haleem, M.; Hall, D.; Halladjian, G.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamer, M.; Hamilton, A.; Hamilton, S.; Hamity, G. N.; Hamnett, P. G.; Han, L.; Hanagaki, K.; Hanawa, K.; Hance, M.; Hanke, P.; Hanna, R.; Hansen, J. B.; Hansen, J. D.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Hariri, F.; Harkusha, S.; Harper, D.; Harrington, R. D.; Harris, O. M.; Harrison, P. F.; Hartjes, F.; Hasegawa, M.; Hasegawa, S.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauschild, M.; Hauser, R.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hawkins, A. D.; Hayashi, T.; Hayden, D.; Hays, C. P.; Hayward, H. S.; Haywood, S. J.; Head, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, L.; Hejbal, J.; Helary, L.; Heller, C.; Heller, M.; Hellman, S.; Hellmich, D.; Helsens, C.; Henderson, J.; Henderson, R. C. W.; Heng, Y.; Hengler, C.; Henrichs, A.; Henriques Correia, A. M.; Henrot-Versille, S.; Hensel, C.; Herbert, G. H.; Hernández Jiménez, Y.; Herrberg-Schubert, R.; Herten, G.; Hertenberger, R.; Hervas, L.; Hesketh, G. G.; Hessey, N. P.; Hickling, R.; Higón-Rodriguez, E.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillert, S.; Hillier, S. J.; Hinchliffe, I.; Hines, E.; Hirose, M.; Hirschbuehl, D.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hodgson, P.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hoffman, J.; Hoffmann, D.; Hofmann, J. I.; Hohlfeld, M.; Holmes, T. R.; Hong, T. M.; Hooft van Huysduynen, L.; Hopkins, W. H.; Horii, Y.; Hostachy, J.-Y.; Hou, S.; Hoummada, A.; Howard, J.; Howarth, J.; Hrabovsky, M.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hsu, C.; Hsu, P. J.; Hsu, S.-C.; Hu, D.; Hu, X.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Hughes, G.; Huhtinen, M.; Hülsing, T. A.; Hurwitz, M.; Huseynov, N.; Huston, J.; Huth, J.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Ideal, E.; Iengo, P.; Igonkina, O.; Iizawa, T.; Ikegami, Y.; Ikematsu, K.; Ikeno, M.; Ilchenko, Y.; Iliadis, D.; Ilic, N.; Inamaru, Y.; Ince, T.; Ioannou, P.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Irles Quiles, A.; Isaksson, C.; Ishino, M.; Ishitsuka, M.; Ishmukhametov, R.; Issever, C.; Istin, S.; Iturbe Ponce, J. M.; Iuppa, R.; Ivarsson, J.; Iwanski, W.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jackson, B.; Jackson, M.; Jackson, P.; Jaekel, M. R.; Jain, V.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jakubek, J.; Jamin, D. O.; Jana, D. K.; Jansen, E.; Jansen, H.; Janssen, J.; Janus, M.; Jarlskog, G.; Javadov, N.; Javůrek, T.; Jeanty, L.; Jejelava, J.; Jeng, G.-Y.; Jennens, D.; Jenni, P.; Jentzsch, J.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, Y.; Jimenez Belenguer, M.; Jin, S.; Jinaru, A.; Jinnouchi, O.; Joergensen, M. D.; Johansson, K. E.; Johansson, P.; Johns, K. A.; Jon-And, K.; Jones, G.; Jones, R. W. L.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Joshi, K. D.; Jovicevic, J.; Ju, X.; Jung, C. A.; Jungst, R. M.; Jussel, P.; Juste Rozas, A.; Kaci, M.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kajomovitz, E.; Kalderon, C. W.; Kama, S.; Kamenshchikov, A.; Kanaya, N.; Kaneda, M.; Kaneti, S.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kapliy, A.; Kar, D.; Karakostas, K.; Karastathis, N.; Kareem, M. J.; Karnevskiy, M.; Karpov, S. N.; Karpova, Z. M.; Karthik, K.; Kartvelishvili, V.; Karyukhin, A. N.; Kashif, L.; Kasieczka, G.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Katre, A.; Katzy, J.; Kaushik, V.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kazama, S.; Kazanin, V. F.; Kazarinov, M. Y.; Keeler, R.; Kehoe, R.; Keil, M.; Keller, J. S.; Kempster, J. J.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Kessoku, K.; Keung, J.; Khalil-zada, F.; Khandanyan, H.; Khanov, A.; Khodinov, A.; Khomich, A.; Khoo, T. J.; Khoriauli, G.; Khoroshilov, A.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kim, H. Y.; Kim, H.; Kim, S. H.; Kimura, N.; Kind, O.; King, B. T.; King, M.; King, R. S. B.; King, S. B.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kiss, F.; Kittelmann, T.; Kiuchi, K.; Kladiva, E.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klinger, J. A.; Klioutchnikova, T.; Klok, P. F.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koevesarki, P.; Koffas, T.; Koffeman, E.; Kogan, L. A.; Kohlmann, S.; Kohout, Z.; Kohriki, T.; Koi, T.; Kolanoski, H.; Koletsou, I.; Koll, J.; Komar, A. A.; Komori, Y.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; König, S.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Kopeliansky, R.; Koperny, S.; Köpke, L.; Kopp, A. K.; Korcyl, K.; Kordas, K.; Korn, A.; Korol, A. A.; Korolkov, I.; Korolkova, E. V.; Korotkov, V. A.; Kortner, O.; Kortner, S.; Kostyukhin, V. V.; Kotov, V. M.; Kotwal, A.; Kourkoumelis, C.; Kouskoura, V.; Koutsman, A.; Kowalewski, R.; Kowalski, T. Z.; Kozanecki, W.; Kozhin, A. S.; Kral, V.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Kraus, J. K.; Kravchenko, A.; Kreiss, S.; Kretz, M.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Kruker, T.; Krumnack, N.; Krumshteyn, Z. V.; Kruse, A.; Kruse, M. C.; Kruskal, M.; Kubota, T.; Kuday, S.; Kuehn, S.; Kugel, A.; Kuhl, A.; Kuhl, T.; Kukhtin, V.; Kulchitsky, Y.; Kuleshov, S.; Kuna, M.; Kunkle, J.; Kupco, A.; Kurashige, H.; Kurochkin, Y. A.; Kurumida, R.; Kus, V.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; La Rosa, A.; La Rotonda, L.; Lacasta, C.; Lacava, F.; Lacey, J.; Lacker, H.; Lacour, D.; Lacuesta, V. R.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lagouri, T.; Lai, S.; Laier, H.; Lambourne, L.; Lammers, S.; Lampen, C. L.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lang, V. S.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Laplace, S.; Lapoire, C.; Laporte, J. F.; Lari, T.; Lasagni Manghi, F.; Lassnig, M.; Laurelli, P.; Lavrijsen, W.; Law, A. T.; Laycock, P.; Le Dortz, O.; Le Guirriec, E.; Le Menedeu, E.; LeCompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, H.; Lee, J. S. H.; Lee, S. C.; Lee, L.; Lefebvre, G.; Lefebvre, M.; Legger, F.; Leggett, C.; Lehan, A.; Lehmacher, M.; Lehmann Miotto, G.; Lei, X.; Leight, W. A.; Leisos, A.; Leister, A. G.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzen, G.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Leontsinis, S.; Leroy, C.; Lester, C. G.; Lester, C. M.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Lewis, A.; Lewis, G. H.; Leyko, A. M.; Leyton, M.; Li, B.; Li, B.; Li, H.; Li, H. L.; Li, L.; Li, L.; Li, S.; Li, Y.; Liang, Z.; Liao, H.; Liberti, B.; Lichard, P.; Lie, K.; Liebal, J.; Liebig, W.; Limbach, C.; Limosani, A.; Lin, S. C.; Lin, T. H.; Linde, F.; Lindquist, B. E.; Linnemann, J. T.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lissauer, D.; Lister, A.; Litke, A. M.; Liu, B.; Liu, D.; Liu, J. B.; Liu, K.; Liu, L.; Liu, M.; Liu, M.; Liu, Y.; Livan, M.; Livermore, S. S. A.; Lleres, A.; Llorente Merino, J.; Lloyd, S. L.; Lo Sterzo, F.; Lobodzinska, E.; Loch, P.; Lockman, W. S.; Loddenkoetter, T.; Loebinger, F. K.; Loevschall-Jensen, A. E.; Loginov, A.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Lombardo, V. P.; Long, B. A.; Long, J. D.; Long, R. E.; Lopes, L.; Lopez Mateos, D.; Lopez Paredes, B.; Lopez Paz, I.; Lorenz, J.; Lorenzo Martinez, N.; Losada, M.; Loscutoff, P.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lowe, A. J.; Lu, F.; Lu, N.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luehring, F.; Lukas, W.; Luminari, L.; Lundberg, O.; Lund-Jensen, B.; Lungwitz, M.; Lynn, D.; Lysak, R.; Lytken, E.; Ma, H.; Ma, L. L.; Maccarrone, G.; Macchiolo, A.; Machado Miguens, J.; Macina, D.; Madaffari, D.; Madar, R.; Maddocks, H. J.; Mader, W. F.; Madsen, A.; Maeno, M.; Maeno, T.; Maevskiy, A.; Magradze, E.; Mahboubi, K.; Mahlstedt, J.; Mahmoud, S.; Maiani, C.; Maidantchik, C.; Maier, A. A.; Maio, A.; Majewski, S.; Makida, Y.; Makovec, N.; Mal, P.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyshev, V. M.; Malyukov, S.; Mamuzic, J.; Mandelli, B.; Mandelli, L.; Mandić, I.; Mandrysch, R.; Maneira, J.; Manfredini, A.; Manhaes de Andrade Filho, L.; Manjarres Ramos, J. A.; Mann, A.; Manning, P. M.; Manousakis-Katsikakis, A.; Mansoulie, B.; Mantifel, R.; Mapelli, L.; March, L.; Marchand, J. F.; Marchiori, G.; Marcisovsky, M.; Marino, C. P.; Marjanovic, M.; Marques, C. N.; Marroquim, F.; Marsden, S. P.; Marshall, Z.; Marti, L. F.; Marti-Garcia, S.; Martin, B.; Martin, B.; Martin, T. A.; Martin, V. J.; Martin dit Latour, B.; Martinez, H.; Martinez, M.; Martin-Haugh, S.; Martyniuk, A. C.; Marx, M.; Marzano, F.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Massa, I.; Massa, L.; Massol, N.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Mattmann, J.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Mazzaferro, L.; Mc Goldrick, G.; Mc Kee, S. P.; McCarn, A.; McCarthy, R. L.; McCarthy, T. G.; McCubbin, N. A.; McFarlane, K. W.; Mcfayden, J. A.; Mchedlidze, G.; McMahon, S. J.; McPherson, R. A.; Mechnich, J.; Medinnis, M.; Meehan, S.; Mehlhase, S.; Mehta, A.; Meier, K.; Meineck, C.; Meirose, B.; Melachrinos, C.; Mellado Garcia, B. R.; Meloni, F.; Mengarelli, A.; Menke, S.; Meoni, E.; Mercurio, K. M.; Mergelmeyer, S.; Meric, N.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Merritt, H.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Middleton, R. P.; Migas, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milic, A.; Miller, D. W.; Mills, C.; Milov, A.; Milstead, D. A.; Milstein, D.; Minaenko, A. A.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Ming, Y.; Mir, L. M.; Mirabelli, G.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Mitsui, S.; Miucci, A.; Miyagawa, P. S.; Mjörnmark, J. U.; Moa, T.; Mochizuki, K.; Mohapatra, S.; Mohr, W.; Molander, S.; Moles-Valls, R.; Mönig, K.; Monini, C.; Monk, J.; Monnier, E.; Montejo Berlingen, J.; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Moreno Llácer, M.; Morettini, P.; Morgenstern, M.; Morii, M.; Moritz, S.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Morvaj, L.; Moser, H. G.; Mosidze, M.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Mouraviev, S. V.; Moyse, E. J. W.; Muanza, S.; Mudd, R. D.; Mueller, F.; Mueller, J.; Mueller, K.; Mueller, T.; Mueller, T.; Muenstermann, D.; Munwes, Y.; Murillo Quijada, J. A.; Murray, W. J.; Musheghyan, H.; Musto, E.; Myagkov, A. G.; Myska, M.; Nackenhorst, O.; Nadal, J.; Nagai, K.; Nagai, R.; Nagai, Y.; Nagano, K.; Nagarkar, A.; Nagasaka, Y.; Nagel, M.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Namasivayam, H.; Nanava, G.; Narayan, R.; Nattermann, T.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Nef, P. D.; Negri, A.; Negri, G.; Negrini, M.; Nektarijevic, S.; Nelson, A.; Nelson, T. K.; Nemecek, S.; Nemethy, P.; Nepomuceno, A. A.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Neves, R. M.; Nevski, P.; Newman, P. R.; Nguyen, D. H.; Nickerson, R. B.; Nicolaidou, R.; Nicquevert, B.; Nielsen, J.; Nikiforou, N.; Nikiforov, A.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolics, K.; Nikolopoulos, K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nisius, R.; Nobe, T.; Nodulman, L.; Nomachi, M.; Nomidis, I.; Norberg, S.; Nordberg, M.; Novgorodova, O.; Nowak, S.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nunes Hanninger, G.; Nunnemann, T.; Nurse, E.; Nuti, F.; O'Brien, B. J.; O'grady, F.; O'Neil, D. C.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, M. I.; Oda, S.; Odaka, S.; Ogren, H.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Okamura, W.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Olchevski, A. G.; Olivares Pino, S. A.; Oliveira Damazio, D.; Oliver Garcia, E.; Olszewski, A.; Olszowska, J.; Onofre, A.; Onyisi, P. U. E.; Oram, C. J.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orlando, N.; Oropeza Barrera, C.; Orr, R. S.; Osculati, B.; Ospanov, R.; Otero y Garzon, G.; Otono, H.; Ouchrif, M.; Ouellette, E. A.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Ovcharova, A.; Owen, M.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pacheco Pages, A.; Padilla Aranda, C.; Pagáčová, M.; Pagan Griso, S.; Paganis, E.; Pahl, C.; Paige, F.; Pais, P.; Pajchel, K.; Palacino, G.; Palestini, S.; Palka, M.; Pallin, D.; Palma, A.; Palmer, J. D.; Pan, Y. B.; Panagiotopoulou, E.; Panduro Vazquez, J. G.; Pani, P.; Panikashvili, N.; Panitkin, S.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Paredes Hernandez, D.; Parker, M. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pasqualucci, E.; Passaggio, S.; Passeri, A.; Pastore, F.; Pastore, Fr.; Pásztor, G.; Pataraia, S.; Patel, N. D.; Pater, J. R.; Patricelli, S.; Pauly, T.; Pearce, J.; Pedersen, L. E.; Pedersen, M.; Pedraza Lopez, S.; Pedro, R.; Peleganchuk, S. V.; Pelikan, D.; Peng, H.; Penning, B.; Penwell, J.; Perepelitsa, D. V.; Perez Codina, E.; Pérez García-Estañ, M. T.; Perez Reale, V.; Perini, L.; Pernegger, H.; Perrella, S.; Perrino, R.; Peschke, R.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petrolo, E.; Petrucci, F.; Pettersson, N. E.; Pezoa, R.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Piccaro, E.; Piccinini, M.; Piegaia, R.; Pignotti, D. T.; Pilcher, J. E.; Pilkington, A. D.; Pina, J.; Pinamonti, M.; Pinder, A.; Pinfold, J. L.; Pingel, A.; Pinto, B.; Pires, S.; Pitt, M.; Pizio, C.; Plazak, L.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Plucinski, P.; Poddar, S.; Podlyski, F.; Poettgen, R.; Poggioli, L.; Pohl, D.; Pohl, M.; Polesello, G.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Pommès, K.; Pontecorvo, L.; Pope, B. G.; Popeneciu, G. A.; Popovic, D. S.; Poppleton, A.; Portell Bueso, X.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Potter, C. T.; Poulard, G.; Poveda, J.; Pozdnyakov, V.; Pralavorio, P.; Pranko, A.; Prasad, S.; Pravahan, R.; Prell, S.; Price, D.; Price, J.; Price, L. E.; Prieur, D.; Primavera, M.; Proissl, M.; Prokofiev, K.; Prokoshin, F.; Protopapadaki, E.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Przysiezniak, H.; Ptacek, E.; Puddu, D.; Pueschel, E.; Puldon, D.; Purohit, M.; Puzo, P.; Qian, J.; Qin, G.; Qin, Y.; Quadt, A.; Quarrie, D. R.; Quayle, W. B.; Queitsch-Maitland, M.; Quilty, D.; Qureshi, A.; Radeka, V.; Radescu, V.; Radhakrishnan, S. K.; Radloff, P.; Rados, P.; Ragusa, F.; Rahal, G.; Rajagopalan, S.; Rammensee, M.; Randle-Conde, A. S.; Rangel-Smith, C.; Rao, K.; Rauscher, F.; Rave, T. C.; Ravenscroft, T.; Raymond, M.; Read, A. L.; Readioff, N. P.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reeves, K.; Rehnisch, L.; Reisin, H.; Relich, M.; Rembser, C.; Ren, H.; Ren, Z. L.; Renaud, A.; Rescigno, M.; Resconi, S.; Rezanova, O. L.; Reznicek, P.; Rezvani, R.; Richter, R.; Ridel, M.; Rieck, P.; Rieger, J.; Rijssenbeek, M.; Rimoldi, A.; Rinaldi, L.; Ritsch, E.; Riu, I.; Rizatdinova, F.; Rizvi, E.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Roda, C.; Rodrigues, L.; Roe, S.; Røhne, O.; Rolli, S.; Romaniouk, A.; Romano, M.; Romero Adam, E.; Rompotis, N.; Ronzani, M.; Roos, L.; Ros, E.; Rosati, S.; Rosbach, K.; Rose, M.; Rose, P.; Rosendahl, P. L.; Rosenthal, O.; Rossetti, V.; Rossi, E.; Rossi, L. P.; Rosten, R.; Rotaru, M.; Roth, I.; Rothberg, J.; Rousseau, D.; Royon, C. R.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Rubinskiy, I.; Rud, V. I.; Rudolph, C.; Rudolph, M. S.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Ruschke, A.; Rutherfoord, J. P.; Ruthmann, N.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryder, N. C.; Saavedra, A. F.; Sacerdoti, S.; Saddique, A.; Sadeh, I.; Sadrozinski, H. F.-W.; Sadykov, R.; Safai Tehrani, F.; Sakamoto, H.; Sakurai, Y.; Salamanna, G.; Salamon, A.; Saleem, M.; Salek, D.; Sales De Bruin, P. H.; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sampsonidis, D.; Sanchez, A.; Sánchez, J.; Sanchez Martinez, V.; Sandaker, H.; Sandbach, R. L.; Sander, H. G.; Sanders, M. P.; Sandhoff, M.; Sandoval, T.; Sandoval, C.; Sandstroem, R.; Sankey, D. P. C.; Sansoni, A.; Santoni, C.; Santonico, R.; Santos, H.; Santoyo Castillo, I.; Sapp, K.; Sapronov, A.; Saraiva, J. G.; Sarrazin, B.; Sartisohn, G.; Sasaki, O.; Sasaki, Y.; Sauvage, G.; Sauvan, E.; Savard, P.; Savu, D. O.; Sawyer, C.; Sawyer, L.; Saxon, D. H.; Saxon, J.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Scarcella, M.; Scarfone, V.; Schaarschmidt, J.; Schacht, P.; Schaefer, D.; Schaefer, R.; Schaepe, S.; Schaetzel, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Scharf, V.; Schegelsky, V. A.; Scheirich, D.; Schernau, M.; Scherzer, M. I.; Schiavi, C.; Schieck, J.; Schillo, C.; Schioppa, M.; Schlenker, S.; Schmidt, E.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schneider, B.; Schnellbach, Y. J.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schoenrock, B. D.; Schorlemmer, A. L. S.; Schott, M.; Schouten, D.; Schovancova, J.; Schramm, S.; Schreyer, M.; Schroeder, C.; Schuh, N.; Schultens, M. J.; Schultz-Coulon, H.-C.; Schulz, H.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwanenberger, C.; Schwartzman, A.; Schwarz, T. A.; Schwegler, Ph.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Schwindt, T.; Schwoerer, M.; Sciacca, F. G.; Scifo, E.; Sciolla, G.; Scott, W. G.; Scuri, F.; Scutti, F.; Searcy, J.; Sedov, G.; Sedykh, E.; Seidel, S. C.; Seiden, A.; Seifert, F.; Seixas, J. M.; Sekhniaidze, G.; Sekula, S. J.; Selbach, K. E.; Seliverstov, D. M.; Sellers, G.; Semprini-Cesari, N.; Serfon, C.; Serin, L.; Serkin, L.; Serre, T.; Seuster, R.; Severini, H.; Sfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shamim, M.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Shatalov, P. B.; Shaw, K.; Shehu, C. Y.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shiyakova, M.; Shmeleva, A.; Shochet, M. J.; Short, D.; Shrestha, S.; Shulga, E.; Shupe, M. A.; Shushkevich, S.; Sicho, P.; Sidiropoulou, O.; Sidorov, D.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silver, Y.; Silverstein, D.; Silverstein, S. B.; Simak, V.; Simard, O.; Simic, Lj.; Simion, S.; Simioni, E.; Simmons, B.; Simoniello, R.; Simonyan, M.; Sinervo, P.; Sinev, N. B.; Sipica, V.; Siragusa, G.; Sircar, A.; Sisakyan, A. N.; Sivoklokov, S. Yu.; Sjölin, J.; Sjursen, T. B.; Skottowe, H. P.; Skovpen, K. Yu.; Skubic, P.; Slater, M.; Slavicek, T.; Sliwa, K.; Smakhtin, V.; Smart, B. H.; Smestad, L.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, K. M.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snidero, G.; Snyder, S.; Sobie, R.; Socher, F.; Soffer, A.; Soh, D. A.; Solans, C. A.; Solar, M.; Solc, J.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Song, H. Y.; Soni, N.; Sood, A.; Sopczak, A.; Sopko, B.; Sopko, V.; Sorin, V.; Sosebee, M.; Soualah, R.; Soueid, P.; Soukharev, A. M.; South, D.; Spagnolo, S.; Spanò, F.; Spearman, W. R.; Spettel, F.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; Spreitzer, T.; Spurlock, B.; St. Denis, R. D.; Staerz, S.; Stahlman, J.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanek, R. W.; Stanescu, C.; Stanescu-Bellu, M.; Stanitzki, M. M.; Stapnes, S.; Starchenko, E. A.; Stark, J.; Staroba, P.; Starovoitov, P.; Staszewski, R.; Stavina, P.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stern, S.; Stewart, G. A.; Stillings, J. A.; Stockton, M. C.; Stoebe, M.; Stoicea, G.; Stolte, P.; Stonjek, S.; Stradling, A. R.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strandlie, A.; Strauss, E.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Struebig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Subramaniam, R.; Succurro, A.; Sugaya, Y.; Suhr, C.; Suk, M.; Sulin, V. V.; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Sundermann, J. E.; Suruliz, K.; Susinno, G.; Sutton, M. R.; Suzuki, Y.; Svatos, M.; Swedish, S.; Swiatlowski, M.; Sykora, I.; Sykora, T.; Ta, D.; Taccini, C.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Taiblum, N.; Takai, H.; Takashima, R.; Takeda, H.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tam, J. Y. C.; Tan, K. G.; Tanaka, J.; Tanaka, R.; Tanaka, S.; Tanaka, S.; Tanasijczuk, A. J.; Tannenwald, B. B.; Tannoury, N.; Tapprogge, S.; Tarem, S.; Tarrade, F.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Tavares Delgado, A.; Tayalati, Y.; Taylor, F. E.; Taylor, G. N.; Taylor, W.; Teischinger, F. A.; Teixeira Dias Castanheira, M.; Teixeira-Dias, P.; Temming, K. K.; Ten Kate, H.; Teng, P. K.; Teoh, J. J.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Therhaag, J.; Theveneaux-Pelzer, T.; Thomas, J. P.; Thomas-Wilsker, J.; Thompson, E. N.; Thompson, P. D.; Thompson, P. D.; Thompson, R. J.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Thomson, M.; Thong, W. M.; Thun, R. P.; Tian, F.; Tibbetts, M. J.; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tiouchichine, E.; Tipton, P.; Tisserant, S.; Todorov, T.; Todorova-Nova, S.; Toggerson, B.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tollefson, K.; Tolley, E.; Tomlinson, L.; Tomoto, M.; Tompkins, L.; Toms, K.; Topilin, N. D.; Torrence, E.; Torres, H.; Torró Pastor, E.; Toth, J.; Touchard, F.; Tovey, D. R.; Tran, H. L.; Trefzger, T.; Tremblet, L.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Troncon, C.; Trottier-McDonald, M.; Trovatelli, M.; True, P.; Trzebinski, M.; Trzupek, A.; Tsarouchas, C.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsionou, D.; Tsipolitis, G.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tudorache, A.; Tudorache, V.; Tuna, A. N.; Tupputi, S. A.; Turchikhin, S.; Turecek, D.; Turk Cakir, I.; Turra, R.; Tuts, P. M.; Tykhonov, A.; Tylmad, M.; Tyndel, M.; Uchida, K.; Ueda, I.; Ueno, R.; Ughetto, M.; Ugland, M.; Uhlenbrock, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Unverdorben, C.; Urbaniec, D.; Urquijo, P.; Usai, G.; Usanova, A.; Vacavant, L.; Vacek, V.; Vachon, B.; Valencic, N.; Valentinetti, S.; Valero, A.; Valery, L.; Valkar, S.; Valladolid Gallego, E.; Vallecorsa, S.; Valls Ferrer, J. A.; Van Den Wollenberg, W.; Van Der Deijl, P. C.; van der Geer, R.; van der Graaf, H.; Van Der Leeuw, R.; van der Ster, D.; van Eldik, N.; van Gemmeren, P.; Van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vanguri, R.; Vaniachine, A.; Vankov, P.; Vannucci, F.; Vardanyan, G.; Vari, R.; Varnes, E. W.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vazeille, F.; Vazquez Schroeder, T.; Veatch, J.; Veloso, F.; Veneziano, S.; Ventura, A.; Ventura, D.; Venturi, M.; Venturi, N.; Venturini, A.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, J. C.; Vest, A.; Vetterli, M. C.; Viazlo, O.; Vichou, I.; Vickey, T.; Vickey Boeriu, O. E.; Viehhauser, G. H. A.; Viel, S.; Vigne, R.; Villa, M.; Villaplana Perez, M.; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Virzi, J.; Vivarelli, I.; Vives Vaque, F.; Vlachos, S.; Vladoiu, D.; Vlasak, M.; Vogel, A.; Vogel, M.; Vokac, P.; Volpi, G.; Volpi, M.; von der Schmitt, H.; von Radziewski, H.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Voss, R.; Vossebeld, J. H.; Vranjes, N.; Vranjes Milosavljevic, M.; Vrba, V.; Vreeswijk, M.; Anh, T. Vu; Vuillermet, R.; Vukotic, I.; Vykydal, Z.; Wagner, P.; Wagner, W.; Wahlberg, H.; Wahrmund, S.; Wakabayashi, J.; Walder, J.; Walker, R.; Walkowiak, W.; Wall, R.; Waller, P.; Walsh, B.; Wang, C.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, K.; Wang, R.; Wang, S. M.; Wang, T.; Wang, X.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Warsinsky, M.; Washbrook, A.; Wasicki, C.; Watkins, P. M.; Watson, A. T.; Watson, I. J.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, S.; Weber, M. S.; Weber, S. W.; Webster, J. S.; Weidberg, A. R.; Weigell, P.; Weinert, B.; Weingarten, J.; Weiser, C.; Weits, H.; Wells, P. S.; Wenaus, T.; Wendland, D.; Weng, Z.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M.; Werner, P.; Wessels, M.; Wetter, J.; Whalen, K.; White, A.; White, M. J.; White, R.; White, S.; Whiteson, D.; Wicke, D.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wienemann, P.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wijeratne, P. A.; Wildauer, A.; Wildt, M. A.; Wilkens, H. G.; Will, J. Z.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, A.; Wilson, J. A.; Wingerter-Seez, I.; Winklmeier, F.; Winter, B. T.; Wittgen, M.; Wittig, T.; Wittkowski, J.; Wollstadt, S. J.; Wolter, M. W.; Wolters, H.; Wosiek, B. K.; Wotschack, J.; Woudstra, M. J.; Wozniak, K. W.; Wright, M.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wulf, E.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xiao, M.; Xu, D.; Xu, L.; Yabsley, B.; Yacoob, S.; Yakabe, R.; Yamada, M.; Yamaguchi, H.; Yamaguchi, Y.; Yamamoto, A.; Yamamoto, K.; Yamamoto, S.; Yamamura, T.; Yamanaka, T.; Yamauchi, K.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, U. K.; Yang, Y.; Yanush, S.; Yao, L.; Yao, W.-M.; Yasu, Y.; Yatsenko, E.; Yau Wong, K. H.; Ye, J.; Ye, S.; Yeletskikh, I.; Yen, A. L.; Yildirim, E.; Yilmaz, M.; Yoosoofmiya, R.; Yorita, K.; Yoshida, R.; Yoshihara, K.; Young, C.; Young, C. J. S.; Youssef, S.; Yu, D. R.; Yu, J.; Yu, J. M.; Yu, J.; Yuan, L.; Yurkewicz, A.; Yusuff, I.; Zabinski, B.; Zaidan, R.; Zaitsev, A. M.; Zaman, A.; Zambito, S.; Zanello, L.; Zanzi, D.; Zeitnitz, C.; Zeman, M.; Zemla, A.; Zengel, K.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zevi della Porta, G.; Zhang, D.; Zhang, F.; Zhang, H.; Zhang, J.; Zhang, L.; Zhang, X.; Zhang, Z.; Zhao, Z.; Zhemchugov, A.; Zhong, J.; Zhou, B.; Zhou, L.; Zhou, N.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, C.; Zimmermann, R.; Zimmermann, S.; Zimmermann, S.; Zinonos, Z.; Ziolkowski, M.; Zobernig, G.; Zoccoli, A.; zur Nedden, M.; Zurzolo, G.; Zutshi, V.; Zwalinski, L.

    2015-09-01

    It was found that the non-perturbative corrections calculated using Pythia with the Perugia 2011 tune did not include the effect of the underlying event. The affected correction factors were recomputed using the Pythia 6.427 generator. These corrections are applied as baseline to the NLO pQCD calculations and thus the central values of the theoretical predictions have changed by a few percent with the new corrections. This has a minor impact on the agreement between the data and the theoretical predictions. Figures 2 and 6 to 13, and all the tables have been updated with the new values. A few sentences in the discussion in sections 5.2 and 9 were altered or removed. [Figure not available: see fulltext.

  10. Night firing range performance following photorefractive keratectomy and laser in situ keratomileusis.

    PubMed

    Bower, Kraig S; Burka, Jenna M; Subramanian, Prem S; Stutzman, Richard D; Mines, Michael J; Rabin, Jeff C

    2006-06-01

    To investigate the effect of laser refractive surgery on night weapons firing. Firing range performance was measured at baseline and postoperatively following photorefractive keratectomy and laser in situ keratomileusis. Subjects fired the M-16A2 rifle with night vision goggles (NVG) at starlight, and with iron sight (simulated dusk). Scores, before and after surgery, were compared for both conditions. No subject was able to acquire the target using iron sight without correction before surgery. After surgery, the scores without correction (95.9 +/- 4.7) matched the preoperative scores with correction (94.3 +/- 4.0; p = 0.324). Uncorrected NVG scores after surgery (96.4 +/- 3.1) exceeded the corrected scores before surgery (91.4 +/- 10.2), but this trend was not statistically significant (p = 0.063). Night weapon firing with both the iron sight and the NVG sight improved after surgery. This study supports the operational benefits of refractive surgery in the military.

  11. Assessing the Utility of Strong Motion Data to Determine Static Ground Displacements During Great Megathrust Earthquakes: Tohoku and Iquique

    NASA Astrophysics Data System (ADS)

    Herman, M. W.; Furlong, K. P.; Hayes, G. P.; Benz, H.

    2014-12-01

    Strong motion accelerometers can record large amplitude shaking on-scale in the near-field of large earthquake ruptures; however, numerical integration of such records to determine displacement is typically unstable due to baseline changes (i.e., distortions in the zero value) that occur during strong shaking. We use datasets from the 2011 Mw 9.0 Tohoku earthquake to assess whether a relatively simple empirical correction scheme (Boore et al., 2002) can return accurate displacement waveforms useful for constraining details of the fault slip. The coseismic deformation resulting from the Tohoku earthquake was recorded by the Kiban Kyoshin network (KiK-net) of strong motion instruments as well as by a dense network of high-rate (1 Hz) GPS instruments. After baseline correcting the KiK-net records and integrating to displacement, over 85% of the KiK-net borehole instrument waveforms and over 75% of the KiK-net surface instrument waveforms match collocated 1 Hz GPS displacement time series. Most of the records that do not match the GPS-derived displacements following the baseline correction have large, systematic drifts that can be automatically identified by examining the slopes in the first 5-10 seconds of the velocity time series. We apply the same scheme to strong motion records from the 2014 Mw 8.2 Iquique earthquake. Close correspondence in both direction and amplitude between coseismic static offsets derived from the integrated strong motion time series and those predicted from a teleseismically-derived finite fault model, as well as displacement amplitudes consistent with InSAR-derived results, suggest that the correction scheme works successfully for the Iquique event. In the absence of GPS displacements, these strong motion-derived offsets provide constraints on the overall distribution of slip on the fault. In addition, the coseismic strong motion-derived displacement time series (50-100 s long) contain a near-field record of the temporal evolution of the rupture, supplementing teleseismic data and improving resolution of the location and timing of moment in finite fault models.

  12. Effects of Interpersonal Skills Training on MRI Operations in a Saturated Market: A Randomized Trial.

    PubMed

    Ajam, Amna A; Nguyen, Xuan V; Kelly, Ronda A; Ladapo, Joseph A; Lang, Elvira V

    2017-07-01

    The aim of this study was to assess the effects of team training on operational efficiency during outpatient MRI. In this institutional review board-approved, HIPAA-compliant study, six MRI outpatient sites of a midwestern hospital system were randomized to serve as controls or have their teams trained in advanced communication skills. The fourth quarter of fiscal year 2015 was the trial baseline. The trial ended in the third quarter (Q3) of fiscal year 2016 (FY16). Equipment utilization (completed scans/available slots), hourly scan rates (total orders completed per machine per hour of operation), and no-show rates stratified by time were analyzed using the Cochran-Mantel-Haenszel method, with individual comparisons performed with Bonferroni correction. The study encompassed 27,425 MRI examinations. Overall volume peaked at baseline and then declined over the following quarters. Compared with baseline, untrained sites experienced significant drops in equipment utilization (P < .01 for the first quarter of FY16 and P < .0001 for the second quarter of FY16 and Q3 FY16), decreasing from 77% to 65% over the study period, corresponding to a decrease from 1.15 to 0.97 in hourly scan rates. For trained sites, these metrics showed no significant change, with maintenance of hourly scan rates of 1.23 and 1.27 and equipment utilization rates of 83% and 85% between baseline and Q3 FY16. No-show rates remained stable at trained sites but increased at untrained sites in the last two quarters (P < .05). Nationally benchmarked patient satisfaction percentile ranking gradually increased at trained sites from 56th at baseline to 70th and successively decreased at untrained sites from 66th to 44th. MRI outpatient facilities trained in advanced communication techniques may have more favorable operational efficiency than untrained sites in a saturated market. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Effect of local magnetic field disturbances on inertial measurement units accuracy.

    PubMed

    Robert-Lachaine, Xavier; Mecheri, Hakim; Larue, Christian; Plamondon, André

    2017-09-01

    Inertial measurement units (IMUs), a practical motion analysis technology for field acquisition, have magnetometers to improve segment orientation estimation. However, sensitivity to magnetic disturbances can affect their accuracy. The objective of this study was to determine the joint angles accuracy of IMUs under different timing of magnetic disturbances of various durations and to evaluate a few correction methods. Kinematics from 12 individuals were obtained simultaneously with an Xsens system where an Optotrak cluster acting as the reference system was affixed to each IMU. A handling task was executed under normal laboratory conditions and imposed magnetic disturbances. Joint angle RMSE was used to conduct a three-way repeated measures analysis of variance in order to contrast the following disturbance factors: duration (0, 30, 60, 120 and 240 s), timing (during the disturbance, directly after it and a 30-second delay after it) and axis (X, Y and Z). The highest joint angle RMSE was observed on rotations about the Y longitudinal axis and during the longer disturbances. It stayed high directly after a disturbance, but returned close to baseline after a 30-second delay. When magnetic disturbances are experienced, waiting 30 s in a normal condition is recommended as a way to restore the IMUs' initial accuracy. The correction methods performed modestly or poorly in the reduction of joint angle RMSE. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Revising shortwave and longwave radiation archives in view of possible revisions of the WSG and WISG reference scales: methods and implications

    NASA Astrophysics Data System (ADS)

    Nyeki, Stephan; Wacker, Stefan; Gröbner, Julian; Finsterle, Wolfgang; Wild, Martin

    2017-08-01

    A large number of radiometers are traceable to the World Standard Group (WSG) for shortwave radiation and the interim World Infrared Standard Group (WISG) for longwave radiation, hosted by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Centre (PMOD/WRC, Davos, Switzerland). The WSG and WISG have recently been found to over- and underestimate radiation values, respectively (Fehlmann et al., 2012; Gröbner et al., 2014), although research is still ongoing. In view of a possible revision of the reference scales of both standard groups, this study discusses the methods involved and the implications on existing archives of radiation time series, such as the Baseline Surface Radiation Network (BSRN). Based on PMOD/WRC calibration archives and BSRN data archives, the downward longwave radiation (DLR) time series over the 2006-2015 period were analysed at four stations (polar and mid-latitude locations). DLR was found to increase by up to 3.5 and 5.4 W m-2 for all-sky and clear-sky conditions, respectively, after applying a WISG reference scale correction and a minor correction for the dependence of pyrgeometer sensitivity on atmospheric integrated water vapour content. Similar increases in DLR may be expected at other BSRN stations. Based on our analysis, a number of recommendations are made for future studies.

  15. Contemporary concepts of the medical therapy of portal hypertension under liver cirrhosis

    PubMed Central

    Garbuzenko, Dmitry Victorovich

    2015-01-01

    Severe complications of liver cirrhosis are mostly related to portal hypertension. At the base of the pathogenesis of portal hypertension is the increase in hepatic vascular resistance to portal blood flow with subsequent development of hyperdynamic circulation, which, despite of the formation of collateral circulation, promotes progression of portal hypertension. An important role in its pathogenesis is played by the rearrangement of vascular bed and angiogenesis. As a result, strategic directions of the therapy of portal hypertension under liver cirrhosis include selectively decreasing hepatic vascular resistance with preserving or increasing portal blood flow, and correcting hyperdynamic circulation and pathological angiogenesis, while striving to reduce the hepatic venous pressure gradient to less than 12 mmHg or 20% of the baseline. Over the last years, substantial progress in understanding the pathophysiological mechanisms of hemodynamic disorders under liver cirrhosis has resulted in the development of new drugs for their correction. Although the majority of them have so far been investigated only in animal experiments, as well as at the molecular and cellular level, it might be expected that the introduction of the new methods in clinical practice will increase the efficacy of the conservative approach to the prophylaxis and treatment of portal hypertension complications. The purpose of the review is to describe the known methods of portal hypertension pharmacotherapy and discuss the drugs that may affect the basic pathogenetic mechanisms of its development. PMID:26034348

  16. Contemporary concepts of the medical therapy of portal hypertension under liver cirrhosis.

    PubMed

    Garbuzenko, Dmitry Victorovich

    2015-05-28

    Severe complications of liver cirrhosis are mostly related to portal hypertension. At the base of the pathogenesis of portal hypertension is the increase in hepatic vascular resistance to portal blood flow with subsequent development of hyperdynamic circulation, which, despite of the formation of collateral circulation, promotes progression of portal hypertension. An important role in its pathogenesis is played by the rearrangement of vascular bed and angiogenesis. As a result, strategic directions of the therapy of portal hypertension under liver cirrhosis include selectively decreasing hepatic vascular resistance with preserving or increasing portal blood flow, and correcting hyperdynamic circulation and pathological angiogenesis, while striving to reduce the hepatic venous pressure gradient to less than 12 mmHg or 20% of the baseline. Over the last years, substantial progress in understanding the pathophysiological mechanisms of hemodynamic disorders under liver cirrhosis has resulted in the development of new drugs for their correction. Although the majority of them have so far been investigated only in animal experiments, as well as at the molecular and cellular level, it might be expected that the introduction of the new methods in clinical practice will increase the efficacy of the conservative approach to the prophylaxis and treatment of portal hypertension complications. The purpose of the review is to describe the known methods of portal hypertension pharmacotherapy and discuss the drugs that may affect the basic pathogenetic mechanisms of its development.

  17. An algorithm developed in Matlab for the automatic selection of cut-off frequencies, in the correction of strong motion data

    NASA Astrophysics Data System (ADS)

    Sakkas, Georgios; Sakellariou, Nikolaos

    2018-05-01

    Strong motion recordings are the key in many earthquake engineering applications and are also fundamental for seismic design. The present study focuses on the automated correction of accelerograms, analog and digital. The main feature of the proposed algorithm is the automatic selection for the cut-off frequencies based on a minimum spectral value in a predefined frequency bandwidth, instead of the typical signal-to-noise approach. The algorithm follows the basic steps of the correction procedure (instrument correction, baseline correction and appropriate filtering). Besides the corrected time histories, Peak Ground Acceleration, Peak Ground Velocity, Peak Ground Displacement values and the corrected Fourier Spectra are also calculated as well as the response spectra. The algorithm is written in Matlab environment, is fast enough and can be used for batch processing or in real-time applications. In addition, the possibility to also perform a signal-to-noise ratio is added as well as to perform causal or acausal filtering. The algorithm has been tested in six significant earthquakes (Kozani-Grevena 1995, Aigio 1995, Athens 1999, Lefkada 2003 and Kefalonia 2014) of the Greek territory with analog and digital accelerograms.

  18. Unwrapping eddy current compensation: improved compensation of eddy current induced baseline shifts in high-resolution phase-contrast MRI at 9.4 Tesla.

    PubMed

    Espe, Emil K S; Zhang, Lili; Sjaastad, Ivar

    2014-10-01

    Phase-contrast MRI (PC-MRI) is a versatile tool allowing evaluation of in vivo motion, but is sensitive to eddy current induced phase offsets, causing errors in the measured velocities. In high-resolution PC-MRI, these offsets can be sufficiently large to cause wrapping in the baseline phase, rendering conventional eddy current compensation (ECC) inadequate. The purpose of this study was to develop an improved ECC technique (unwrapping ECC) able to handle baseline phase discontinuities. Baseline phase discontinuities are unwrapped by minimizing the spatiotemporal standard deviation of the static-tissue phase. Computer simulations were used for demonstrating the theoretical foundation of the proposed technique. The presence of baseline wrapping was confirmed in high-resolution myocardial PC-MRI of a normal rat heart at 9.4 Tesla (T), and the performance of unwrapping ECC was compared with conventional ECC. Areas of phase wrapping in static regions were clearly evident in high-resolution PC-MRI. The proposed technique successfully eliminated discontinuities in the baseline, and resulted in significantly better ECC than the conventional approach. We report the occurrence of baseline phase wrapping in PC-MRI, and provide an improved ECC technique capable of handling its presence. Unwrapping ECC offers improved correction of eddy current induced baseline shifts in high-resolution PC-MRI. Copyright © 2013 Wiley Periodicals, Inc.

  19. A method to correct coordinate distortion in EBSD maps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Y.B., E-mail: yubz@dtu.dk; Elbrønd, A.; Lin, F.X.

    2014-10-15

    Drift during electron backscatter diffraction mapping leads to coordinate distortions in resulting orientation maps, which affects, in some cases significantly, the accuracy of analysis. A method, thin plate spline, is introduced and tested to correct such coordinate distortions in the maps after the electron backscatter diffraction measurements. The accuracy of the correction as well as theoretical and practical aspects of using the thin plate spline method is discussed in detail. By comparing with other correction methods, it is shown that the thin plate spline method is most efficient to correct different local distortions in the electron backscatter diffraction maps. -more » Highlights: • A new method is suggested to correct nonlinear spatial distortion in EBSD maps. • The method corrects EBSD maps more precisely than presently available methods. • Errors less than 1–2 pixels are typically obtained. • Direct quantitative analysis of dynamic data are available after this correction.« less

  20. Aberration corrections for free-space optical communications in atmosphere turbulence using orbital angular momentum states.

    PubMed

    Zhao, S M; Leach, J; Gong, L Y; Ding, J; Zheng, B Y

    2012-01-02

    The effect of atmosphere turbulence on light's spatial structure compromises the information capacity of photons carrying the Orbital Angular Momentum (OAM) in free-space optical (FSO) communications. In this paper, we study two aberration correction methods to mitigate this effect. The first one is the Shack-Hartmann wavefront correction method, which is based on the Zernike polynomials, and the second is a phase correction method specific to OAM states. Our numerical results show that the phase correction method for OAM states outperforms the Shark-Hartmann wavefront correction method, although both methods improve significantly purity of a single OAM state and the channel capacities of FSO communication link. At the same time, our experimental results show that the values of participation functions go down at the phase correction method for OAM states, i.e., the correction method ameliorates effectively the bad effect of atmosphere turbulence.

  1. Should multiple imputation be the method of choice for handling missing data in randomized trials?

    PubMed Central

    Sullivan, Thomas R; White, Ian R; Salter, Amy B; Ryan, Philip; Lee, Katherine J

    2016-01-01

    The use of multiple imputation has increased markedly in recent years, and journal reviewers may expect to see multiple imputation used to handle missing data. However in randomized trials, where treatment group is always observed and independent of baseline covariates, other approaches may be preferable. Using data simulation we evaluated multiple imputation, performed both overall and separately by randomized group, across a range of commonly encountered scenarios. We considered both missing outcome and missing baseline data, with missing outcome data induced under missing at random mechanisms. Provided the analysis model was correctly specified, multiple imputation produced unbiased treatment effect estimates, but alternative unbiased approaches were often more efficient. When the analysis model overlooked an interaction effect involving randomized group, multiple imputation produced biased estimates of the average treatment effect when applied to missing outcome data, unless imputation was performed separately by randomized group. Based on these results, we conclude that multiple imputation should not be seen as the only acceptable way to handle missing data in randomized trials. In settings where multiple imputation is adopted, we recommend that imputation is carried out separately by randomized group. PMID:28034175

  2. Should multiple imputation be the method of choice for handling missing data in randomized trials?

    PubMed

    Sullivan, Thomas R; White, Ian R; Salter, Amy B; Ryan, Philip; Lee, Katherine J

    2016-01-01

    The use of multiple imputation has increased markedly in recent years, and journal reviewers may expect to see multiple imputation used to handle missing data. However in randomized trials, where treatment group is always observed and independent of baseline covariates, other approaches may be preferable. Using data simulation we evaluated multiple imputation, performed both overall and separately by randomized group, across a range of commonly encountered scenarios. We considered both missing outcome and missing baseline data, with missing outcome data induced under missing at random mechanisms. Provided the analysis model was correctly specified, multiple imputation produced unbiased treatment effect estimates, but alternative unbiased approaches were often more efficient. When the analysis model overlooked an interaction effect involving randomized group, multiple imputation produced biased estimates of the average treatment effect when applied to missing outcome data, unless imputation was performed separately by randomized group. Based on these results, we conclude that multiple imputation should not be seen as the only acceptable way to handle missing data in randomized trials. In settings where multiple imputation is adopted, we recommend that imputation is carried out separately by randomized group.

  3. Forecasting Sensorimotor Adaptability from Baseline Inter-Trial Correlations

    NASA Technical Reports Server (NTRS)

    Beaton, K. H.; Bloomberg, J. J.

    2014-01-01

    One of the greatest challenges surrounding adaptation to the spaceflight environment is the large variability in symptoms, and corresponding functional impairments, from one crewmember to the next. This renders preflight training and countermeasure development difficult, as a "one-size-fits-all" approach is inappropriate. Therefore, it would be highly advantageous to know ahead of time which crewmembers might have more difficulty adjusting to the novel g-levels inherent to spaceflight. Such knowledge could guide individually customized countermeasures, which would enable more efficient use of crew time, both preflight and inflight, and provide better outcomes. The primary goal of this project is to look for a baseline performance metric that can forecast sensorimotor adaptability without exposure to an adaptive stimulus. We propose a novel hypothesis that considers baseline inter-trial correlations, the trial-to-trial fluctuations in motor performance, as a predictor of individual sensorimotor adaptive capabilities. To-date, a strong relationship has been found between baseline inter-trial correlations and adaptability in two oculomotor systems. For this project, we will explore an analogous predictive mechanism in the locomotion system. METHODS: Baseline Inter-trial Correlations: Inter-trial correlations specify the relationships among repeated trials of a given task that transpire as a consequence of correcting for previous performance errors over multiple timescales. We can quantify the strength of inter-trial correlations by measuring the decay of the autocorrelation function (ACF), which describes how rapidly information from past trials is "forgotten." Processes whose ACFs decay more slowly exhibit longer-term inter-trial correlations (longer memory processes), while processes whose ACFs decay more rapidly exhibit shorterterm inter-trial correlations (shorter memory processes). Longer-term correlations reflect low-frequency activity, which is more easily measured in the frequency domain. Therefore, we use the power spectrum (PS), which is the Fourier transform of the ACF, to describe our inter-trial correlations. The decay of the PS yields a straight line on a log-log frequency plot, which we quantify by Beta = - (slope of PS on log-log axes). Hence, Beta is a measure of the strength of inter- trial correlations in the baseline data. Larger Beta values are indicative of longer inter-trial correlations. Experimental Approach: We will begin by performing a retrospective analysis of treadmill-gait adaptation data previously collected by Dr. Bloomberg and colleagues. Specifically, we will quantify the strength of inter-trial correlations in the baseline step cadence and heart rate data and compare it to the locomotor adaptability performance results already described by these investigators. Incorporating these datasets will also allow us to explore the applicability of (and potential limitations surrounding) the use of Beta in forecasting physiological performance. We will also perform a new experiment, in which Beta will be derived from baseline data collected during over-ground (non-treadmill) walking, which will enable us to consider locomotor performance, through the parameter Beta, under the most functionallyrelevant, natural gait condition. This experiment will incorporate two baseline and five post-training over-ground locomotion tests to explore the consistency and potential adaptability of the Beta values themselves. HYPOTHESES: We hypothesize that the strength of baseline inter-trial correlations of step cadence and heart rate will relate to locomotor adaptability. Specifically, we anticipate that individuals who show weaker longer-term inter-trial correlations in baseline step cadence data will be the better adaptors, as step cadence can be modified in real-time (i.e., online corrections are an inherent property of the locomotor system; analogous to results observed in the VOR). Conversely, because heart rate is not altered mid-beat, we expect that individuals who demonstrate stronger longer-term correlations in heart rate will be the better adaptors (analogous to results observed in the saccadic system). CONCLUSIONS: At the conclusion of this project we hope to uncover a baseline predictor of locomotor adaptability. If our hypotheses hold true, our results will demonstrate that the temporal structure of baseline behavioral data contains important information that may aid in forecasting adaptive capacities. The ability to predict such adaptability in the sensorimotor system has significant implications for spaceflight, where astronauts must adjust their motor programs following a change in g-level to retain movement accuracy.

  4. Dynamic baseline detection method for power data network service

    NASA Astrophysics Data System (ADS)

    Chen, Wei

    2017-08-01

    This paper proposes a dynamic baseline Traffic detection Method which is based on the historical traffic data for the Power data network. The method uses Cisco's NetFlow acquisition tool to collect the original historical traffic data from network element at fixed intervals. This method uses three dimensions information including the communication port, time, traffic (number of bytes or number of packets) t. By filtering, removing the deviation value, calculating the dynamic baseline value, comparing the actual value with the baseline value, the method can detect whether the current network traffic is abnormal.

  5. Early Mission Maneuver Operations for the Deep Space Climate Observatory Sun-Earth L1 Libration Point Mission

    NASA Technical Reports Server (NTRS)

    Roberts, Craig; Case, Sara; Reagoso, John; Webster, Cassandra

    2015-01-01

    The Deep Space Climate Observatory mission launched on February 11, 2015, and inserted onto a transfer trajectory toward a Lissajous orbit around the Sun-Earth L1 libration point. This paper presents an overview of the baseline transfer orbit and early mission maneuver operations leading up to the start of nominal science orbit operations. In particular, the analysis and performance of the spacecraft insertion, mid-course correction maneuvers, and the deep-space Lissajous orbit insertion maneuvers are discussed, com-paring the baseline orbit with actual mission results and highlighting mission and operations constraints..

  6. Strategic Petroleum Reserve and the Department of Energy's baseline assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Joe LaGrone of DOE's Oak Ridge Operations and John Milloway of the Strategic Petroleum Reserve (SPR) Task Force responded to allegations that the SPR program is providing an inadequate defense and that the program management is guilty of mismanagement and misconduct. The task force prepared a 307-page baseline assessment of the SPR that is critical of past practices, which it feels must be corrected. The assessment does not challenge the viability of the SPR program itself. Two appendices with additional responses from LaGrone and excerpts from the report follow the testimony. (DCK)

  7. A velocity-correction projection method based immersed boundary method for incompressible flows

    NASA Astrophysics Data System (ADS)

    Cai, Shanggui

    2014-11-01

    In the present work we propose a novel direct forcing immersed boundary method based on the velocity-correction projection method of [J.L. Guermond, J. Shen, Velocity-correction projection methods for incompressible flows, SIAM J. Numer. Anal., 41 (1)(2003) 112]. The principal idea of immersed boundary method is to correct the velocity in the vicinity of the immersed object by using an artificial force to mimic the presence of the physical boundaries. Therefore, velocity-correction projection method is preferred to its pressure-correction counterpart in the present work. Since the velocity-correct projection method is considered as a dual class of pressure-correction method, the proposed method here can also be interpreted in the way that first the pressure is predicted by treating the viscous term explicitly without the consideration of the immersed boundary, and the solenoidal velocity is used to determine the volume force on the Lagrangian points, then the non-slip boundary condition is enforced by correcting the velocity with the implicit viscous term. To demonstrate the efficiency and accuracy of the proposed method, several numerical simulations are performed and compared with the results in the literature. China Scholarship Council.

  8. A Revised Embedded Planning Tool for Intensive Reading Instruction

    ERIC Educational Resources Information Center

    Wei, Yan; Lombardi, Allison; Simonsen, Brandi; Coyne, Michael; Faggella-Luby, Michael; Freeman, Jennifer; Kearns, Devin

    2017-01-01

    A single-subject AB multiple-baseline design across participants was utilized to investigate the effectiveness of the Revised Tier Three Instructional Planning (T-TIP) tool on teacher lesson planning, with a focus on corrective and elaborative feedback within intensive literacy instructional settings in secondary schools. Findings revealed that…

  9. Updated fracture incidence rates for the US version of FRAX (registered trademark)

    USDA-ARS?s Scientific Manuscript database

    Evaluation of results produced by the US version of FRAX (trademarked) indicates that this tool overestimates the likelihood of major osteoporotic fracture. In an attempt to correct this, we updated underlying baseline fracture rates for the model. We used US hospital discharge data from 2006 to ca...

  10. Error correction for IFSAR

    DOEpatents

    Doerry, Armin W.; Bickel, Douglas L.

    2002-01-01

    IFSAR images of a target scene are generated by compensating for variations in vertical separation between collection surfaces defined for each IFSAR antenna by adjusting the baseline projection during image generation. In addition, height information from all antennas is processed before processing range and azimuth information in a normal fashion to create the IFSAR image.

  11. Functional Communication Training with Toddlers in Home Environments

    ERIC Educational Resources Information Center

    Dunlap, Glen; Ester, Tera; Langhans, Sherri; Fox, Lise

    2006-01-01

    This study was conducted to examine the effects of functional communication training when used by mothers to address the serious challenging behaviors of toddlers. Multiple baseline (across home routines) designs were used with two mother-child dyads. The data showed mothers used the procedures correctly and interventions produced reductions in…

  12. Teaching Children with Autism Spectrum Disorder to Mand for Information Using "Which?"

    ERIC Educational Resources Information Center

    Marion, Carole; Martin, Garry L.; Yu, C. T.; Buhler, Charissa; Kerr, Danni; Claeys, Amanda

    2012-01-01

    We examined a procedure consisting of a preference assessment, prompting, contrived conditioned establishing operations, and consequences for correct and incorrect responses for teaching children with autism to mand "which?" We used a modified multiple baseline design across 3 participants. All the children learned to mand "which?" Generalization…

  13. Reducing Noise by Repetition: Introduction to Signal Averaging

    ERIC Educational Resources Information Center

    Hassan, Umer; Anwar, Muhammad Sabieh

    2010-01-01

    This paper describes theory and experiments, taken from biophysics and physiological measurements, to illustrate the technique of signal averaging. In the process, students are introduced to the basic concepts of signal processing, such as digital filtering, Fourier transformation, baseline correction, pink and Gaussian noise, and the cross- and…

  14. Instructive Feedback Embedded within Group Instruction for Children Diagnosed with Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Leaf, Justin B.; Cihon, Joseph H.; Alcalay, Aditt; Mitchell, Erin; Townley-Cochran, Donna; Miller, Kevin; Leaf, Ronald; Taubman, Mitchell; McEachin, John

    2017-01-01

    The present study evaluated the effects of instructive feedback embedded within a group discrete trial teaching to teach tact relations to nine children diagnosed with autism spectrum disorder using a nonconcurrent multiple-baseline design. Dependent variables included correct responses for: primary targets (directly taught), secondary targets…

  15. Effect of Initial Conditions on Reproducibility of Scientific Research

    PubMed Central

    Djulbegovic, Benjamin; Hozo, Iztok

    2014-01-01

    Background: It is estimated that about half of currently published research cannot be reproduced. Many reasons have been offered as explanations for failure to reproduce scientific research findings- from fraud to the issues related to design, conduct, analysis, or publishing scientific research. We also postulate a sensitive dependency on initial conditions by which small changes can result in the large differences in the research findings when attempted to be reproduced at later times. Methods: We employed a simple logistic regression equation to model the effect of covariates on the initial study findings. We then fed the input from the logistic equation into a logistic map function to model stability of the results in repeated experiments over time. We illustrate the approach by modeling effects of different factors on the choice of correct treatment. Results: We found that reproducibility of the study findings depended both on the initial values of all independent variables and the rate of change in the baseline conditions, the latter being more important. When the changes in the baseline conditions vary by about 3.5 to about 4 in between experiments, no research findings could be reproduced. However, when the rate of change between the experiments is ≤2.5 the results become highly predictable between the experiments. Conclusions: Many results cannot be reproduced because of the changes in the initial conditions between the experiments. Better control of the baseline conditions in-between the experiments may help improve reproducibility of scientific findings. PMID:25132705

  16. Transcranial motor evoked potential waveform changes in corrective fusion for adolescent idiopathic scoliosis.

    PubMed

    Kobayashi, Kazuyoshi; Imagama, Shiro; Ito, Zenya; Ando, Kei; Hida, Tetsuro; Ito, Kenyu; Tsushima, Mikito; Ishikawa, Yoshimoto; Matsumoto, Akiyuki; Nishida, Yoshihiro; Ishiguro, Naoki

    2017-01-01

    OBJECTIVE Corrective surgery for spinal deformities can lead to neurological complications. Several reports have described spinal cord monitoring in surgery for spinal deformity, but only a few have included patients younger than 20 years with adolescent idiopathic scoliosis (AIS). The goal of this study was to evaluate the characteristics of cases with intraoperative transcranial motor evoked potential (Tc-MEP) waveform deterioration during posterior corrective fusion for AIS. METHODS A prospective database was reviewed, comprising 68 patients with AIS who were treated with posterior corrective fusion in a prospective database. A total of 864 muscles in the lower extremities were chosen for monitoring, and acceptable baseline responses were obtained from 819 muscles (95%). Intraoperative Tc-MEP waveform deterioration was defined as a decrease in intraoperative amplitude of ≥ 70% of the control waveform. Age, Cobb angle, flexibility, operative time, estimated blood loss (EBL), intraoperative body temperature, blood pressure, number of levels fused, and correction rate were examined in patients with and without waveform deterioration. RESULTS The patients (3 males and 65 females) had an average age of 14.4 years (range 11-19 years). The mean Cobb angles before and after surgery were 52.9° and 11.9°, respectively, giving a correction rate of 77.4%. Fourteen patients (20%) exhibited an intraoperative waveform change, and these occurred during incision (14%), after screw fixation (7%), during the rotation maneuver (64%), during placement of the second rod after the rotation maneuver (7%), and after intervertebral compression (7%). Most waveform changes recovered after decreased correction or rest. No patient had a motor deficit postoperatively. In multivariate analysis, EBL (OR 1.001, p = 0.085) and number of levels fused (OR 1.535, p = 0.045) were associated with waveform deterioration. CONCLUSIONS Waveform deterioration commonly occurred during rotation maneuvers and more frequently in patients with a larger preoperative Cobb angle. The significant relationships of EBL and number of levels fused with waveform deterioration suggest that these surgical invasions may be involved in waveform deterioration.

  17. Improving correctional healthcare providers’ ability to care for transgender patients: Development and evaluation of a theory-driven cultural and clinical competence intervention

    PubMed Central

    White Hughto, Jaclyn M.; Clark, Kirsty A.; Altice, Frederick L.; Reisner, Sari L.; Kershaw, Trace S.; Pachankis, John E.

    2017-01-01

    Rationale Correctional healthcare providers’ limited cultural and clinical competence to care for transgender patients represents a barrier to care for incarcerated transgender individuals. Objective The present study aimed to adapt, deliver, and evaluate a transgender cultural and clinical competence intervention for correctional healthcare providers. Method In the summer of 2016, a theoretically-informed, group-based intervention to improve transgender cultural and clinical competence was delivered to 34 correctional healthcare providers in New England. A confidential survey assessed providers’ cultural and clinical competence to care for transgender patients, selfefficacy to provide hormone therapy, subjective norms related to transgender care, and willingness to provide gender-affirming care to transgender patients before and after (immediately and 3-months) the intervention. Linear mixed effects regression models were fit to assess change in study outcomes over time. Qualitative exit interviews assessed feasibility and acceptability of the intervention. Results Providers’ willingness to provide gender-affirming care improved immediately post-intervention (β = 0.38; SE = 0.41, p < 0.001) and from baseline to 3-months post-intervention (β = 0.36; SE = 0.09; p < 0.001; omnibus test of fixed effects χ2 = 23.21; p < 0.001). On average, transgender cultural competence (χ2 = 22.49; p < 0.001), medical gender affirmation knowledge (χ2 = 11.24; p = 0.01), self-efficacy to initiate hormones for transgender women, and subjective norms related to transgender care (χ2 = 14.69; p = 0.001) all significantly increased over time. Providers found the intervention to be highly acceptable and recommended that the training be scaled-up to other correctional healthcare providers and expanded to custody staff. Conclusion The intervention increased correctional healthcare providers’ cultural and clinical competence, selfefficacy, subjective norms, and willingness to provide gender-affirming care to transgender patients. Continued efforts should be made to train correctional healthcare providers in culturally and clinically competent gender-affirming care in order to improve the health of incarcerated transgender people. Future efficacy testing of this intervention is warranted. PMID:29096945

  18. GEO-LEO reflectance band inter-comparison with BRDF and atmospheric scattering corrections

    NASA Astrophysics Data System (ADS)

    Chang, Tiejun; Xiong, Xiaoxiong Jack; Keller, Graziela; Wu, Xiangqian

    2017-09-01

    The inter-comparison of the reflective solar bands between the instruments onboard a geostationary orbit satellite and onboard a low Earth orbit satellite is very helpful to assess their calibration consistency. GOES-R was launched on November 19, 2016 and Himawari 8 was launched October 7, 2014. Unlike the previous GOES instruments, the Advanced Baseline Imager on GOES-16 (GOES-R became GOES-16 after November 29 when it reached orbit) and the Advanced Himawari Imager (AHI) on Himawari 8 have onboard calibrators for the reflective solar bands. The assessment of calibration is important for their product quality enhancement. MODIS and VIIRS, with their stringent calibration requirements and excellent on-orbit calibration performance, provide good references. The simultaneous nadir overpass (SNO) and ray-matching are widely used inter-comparison methods for reflective solar bands. In this work, the inter-comparisons are performed over a pseudo-invariant target. The use of stable and uniform calibration sites provides comparison with appropriate reflectance level, accurate adjustment for band spectral coverage difference, reduction of impact from pixel mismatching, and consistency of BRDF and atmospheric correction. The site in this work is a desert site in Australia (latitude -29.0 South; longitude 139.8 East). Due to the difference in solar and view angles, two corrections are applied to have comparable measurements. The first is the atmospheric scattering correction. The satellite sensor measurements are top of atmosphere reflectance. The scattering, especially Rayleigh scattering, should be removed allowing the ground reflectance to be derived. Secondly, the angle differences magnify the BRDF effect. The ground reflectance should be corrected to have comparable measurements. The atmospheric correction is performed using a vector version of the Second Simulation of a Satellite Signal in the Solar Spectrum modeling and BRDF correction is performed using a semi-empirical model. AHI band 1 (0.47μm) shows good matching with VIIRS band M3 with difference of 0.15%. AHI band 5 (1.69μm) shows largest difference in comparison with VIIRS M10.

  19. Mammography screening using independent double reading with consensus: is there a potential benefit for computer-aided detection?

    PubMed

    Skaane, Per; Kshirsagar, Ashwini; Hofvind, Solveig; Jahr, Gunnar; Castellino, Ronald A

    2012-04-01

    Double reading improves the cancer detection rate in mammography screening. Single reading with computer-aided detection (CAD) has been considered to be an alternative to double reading. Little is known about the potential benefit of CAD in breast cancer screening with double reading. To compare prospective independent double reading of screen-film (SFM) and full-field digital (FFDM) mammography in population-based screening with retrospective standalone CAD performance on the baseline mammograms of the screen-detected cancers and subsequent cancers diagnosed during the follow-up period. The study had ethics committee approval. A 5-point rating scale for probability of cancer was used for 23,923 (SFM = 16,983; FFDM = 6940) screening mammograms. Of 208 evaluable cancers, 104 were screen-detected and 104 were subsequent (44 interval and 60 next screening round) cancers. Baseline mammograms of subsequent cancers were retrospectively classified in consensus without information about cancer location, histology, or CAD prompting as normal, non-specific minimal signs, significant minimal signs, and false-negatives. The baseline mammograms of the screen-detected cancers and subsequent cancers were evaluated by CAD. Significant minimal signs and false-negatives were considered 'actionable' and potentially diagnosable if correctly prompted by CAD. CAD correctly marked 94% (98/104) of the baseline mammograms of the screen-detected cancers (SFM = 95% [61/64]; FFDM = 93% [37/40]), including 96% (23/24) of those with discordant interpretations. Considering only those baseline examinations of subsequent cancers prospectively interpreted as normal and retrospectively categorized as 'actionable', CAD input at baseline screening had the potential to increase the cancer detection rate from 0.43% to 0.51% (P = 0.13); and to increase cancer detection by 16% ([104 + 17]/104) and decrease interval cancers by 20% (from 44 to 35). CAD may have the potential to increase cancer detection by up to 16%, and to reduce the number of interval cancers by up to 20% in SFM and FFDM screening programs using independent double reading with consensus review. The influence of true- and false-positive CAD marks on decision-making can, however, only be evaluated in a prospective clinical study.

  20. Effect of single vision soft contact lenses on peripheral refraction.

    PubMed

    Kang, Pauline; Fan, Yvonne; Oh, Kelly; Trac, Kevin; Zhang, Frank; Swarbrick, Helen

    2012-07-01

    To investigate changes in peripheral refraction with under-, full, and over-correction of central refraction with commercially available single vision soft contact lenses (SCLs) in young myopic adults. Thirty-four myopic adult subjects were fitted with Proclear Sphere SCLs to under-correct (+0.75 DS), fully correct, and over-correct (-0.75 DS) their manifest central refractive error. Central and peripheral refraction were measured with no lens wear and subsequently with different levels of SCL central refractive error correction. The uncorrected refractive error was myopic at all locations along the horizontal meridian. Peripheral refraction was relatively hyperopic compared to center at 30 and 35° in the temporal visual field (VF) in low myopes and at 30 and 35° in the temporal VF and 10, 30, and 35° in the nasal VF in moderate myopes. All levels of SCL correction caused a hyperopic shift in refraction at all locations in the horizontal VF. The smallest hyperopic shift was demonstrated with under-correction followed by full correction and then by over-correction of central refractive error. An increase in relative peripheral hyperopia was measured with full correction SCLs compared with no correction in both low and moderate myopes. However, no difference in relative peripheral refraction profiles were found between under-, full, and over-correction. Under-, full, and over-correction of central refractive error with single vision SCLs caused a hyperopic shift in both central and peripheral refraction at all positions in the horizontal meridian. All levels of SCL correction caused the peripheral retina, which initially experienced absolute myopic defocus at baseline with no correction, to experience absolute hyperopic defocus. This peripheral hyperopia may be a possible cause of myopia progression reported with different types and levels of myopia correction.

  1. An Enhanced Butyrylcholinesterase Method to Measure Organophosphorus Nerve Agent Exposure in Humans

    PubMed Central

    Pantazides, Brooke G.; Watson, Caroline M.; Carter, Melissa D.; Crow, Brian S.; Perez, Jonas W.; Blake, Thomas A.; Thomas, Jerry D.; Johnson, Rudolph C.

    2016-01-01

    Organophosphorus nerve agent (OPNA) adducts to butyrylcholinesterase (BChE) can be used to confirm exposure in humans. A highly accurate method to detect G-series and V-series OPNA adducts to BChE in 75 μL of filtered blood, serum, or plasma has been developed using immunomagnetic separation (IMS) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). The reported IMS method captures > 88% of the BChE in a specimen and corrects for matrix effects on peptide calibrators. The optimized method has been used to quantify baseline BChE levels (unadducted and OPNA-adducted) in a matched set of serum, plasma and whole blood (later processed in-house for plasma content) from 192 unexposed individuals to determine the interchangeability of the tested matrices. The results of these measurements demonstrate the ability to accurately measure BChE regardless of the format of the blood specimen received. Criteria for accepting or denying specimens were established through a series of sample stability and processing experiments. The results of these efforts are an optimized and rugged method that is transferrable to other laboratories and an increased understanding of the BChE biomarker in matrix. PMID:24604326

  2. Method of wavefront tilt correction for optical heterodyne detection systems under strong turbulence

    NASA Astrophysics Data System (ADS)

    Xiang, Jing-song; Tian, Xin; Pan, Le-chun

    2014-07-01

    Atmospheric turbulence decreases the heterodyne mixing efficiency of the optical heterodyne detection systems. Wavefront tilt correction is often used to improve the optical heterodyne mixing efficiency. But the performance of traditional centroid tracking tilt correction is poor under strong turbulence conditions. In this paper, a tilt correction method which tracking the peak value of laser spot on focal plane is proposed. Simulation results show that, under strong turbulence conditions, the performance of peak value tracking tilt correction is distinctly better than that of traditional centroid tracking tilt correction method, and the phenomenon of large antenna's performance inferior to small antenna's performance which may be occurred in centroid tracking tilt correction method can also be avoid in peak value tracking tilt correction method.

  3. SU-E-I-38: Improved Metal Artifact Correction Using Adaptive Dual Energy Calibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, X; Elder, E; Roper, J

    2015-06-15

    Purpose: The empirical dual energy calibration (EDEC) method corrects for beam-hardening artifacts, but shows limited performance on metal artifact correction. In this work, we propose an adaptive dual energy calibration (ADEC) method to correct for metal artifacts. Methods: The empirical dual energy calibration (EDEC) method corrects for beam-hardening artifacts, but shows limited performance on metal artifact correction. In this work, we propose an adaptive dual energy calibration (ADEC) method to correct for metal artifacts. Results: Highly attenuating copper rods cause severe streaking artifacts on standard CT images. EDEC improves the image quality, but cannot eliminate the streaking artifacts. Compared tomore » EDEC, the proposed ADEC method further reduces the streaking resulting from metallic inserts and beam-hardening effects and obtains material decomposition images with significantly improved accuracy. Conclusion: We propose an adaptive dual energy calibration method to correct for metal artifacts. ADEC is evaluated with the Shepp-Logan phantom, and shows superior metal artifact correction performance. In the future, we will further evaluate the performance of the proposed method with phantom and patient data.« less

  4. CryoSat Level1b SAR/SARin BaselineC: Product Format and Algorithm Improvements

    NASA Astrophysics Data System (ADS)

    Scagliola, Michele; Fornari, Marco; Di Giacinto, Andrea; Bouffard, Jerome; Féménias, Pierre; Parrinello, Tommaso

    2015-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. Cryosat carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. This allows to reach a significantly improved along track resolution with respect to traditional pulse-width limited altimeters. CryoSat is the first altimetry mission operating in SAR mode and continuous improvements in the Level1 Instrument Processing Facility (IPF1) are being identified, tested and validated in order to improve the quality of the Level1b products. The current IPF, Baseline B, was released in operation in February 2012. A reprocessing campaign followed, in order to reprocess the data since July 2010. After more than 2 years of development, the release in operations of Baseline C is expected in the first half of 2015. BaselineC Level1b products will be distributed in an updated format, including for example the attitude information (roll, pitch and yaw) and, for SAR/SARIN, the waveform length doubled with respect to Baseline B. Moreveor, various algorithm improvements have been identified: • a datation bias of about -0.5195 ms will be corrected (SAR/SARIn) • a range bias of about 0.6730 m will be corrected (SAR/SARIn) • a roll bias of 0.1062 deg and a pitch bias of 0.0520 deg • Surface sample stack weighting to filter out the single look echoes acquired at highest look angle, that results in a sharpening of the 20Hz waveforms With the operational release of BaselineC, the second CryoSat reprocessing campaign will be initiated, taking benefit of the upgrade implemented in the IPF1 processing chain but also at IPF2 level. The reprocessing campaign will cover the full Cryosat mission starting on 16th July 2010. This poster details the new information that will be added in the CryoSat BaselineC Level1b SAR/SARin products and the main quality improvements will be described.

  5. Association between baseline cognitive impairment and postoperative delirium in elderly patients undergoing surgery for adult spinal deformity.

    PubMed

    Adogwa, Owoicho; Elsamadicy, Aladine A; Vuong, Victoria D; Fialkoff, Jared; Cheng, Joseph; Karikari, Isaac O; Bagley, Carlos A

    2018-01-01

    OBJECTIVE Postoperative delirium is common in elderly patients undergoing spine surgery and is associated with a longer and more costly hospital course, functional decline, postoperative institutionalization, and higher likelihood of death within 6 months of discharge. Preoperative cognitive impairment may be a risk factor for the development of postoperative delirium. The aim of this study was to investigate the relationship between baseline cognitive impairment and postoperative delirium in geriatric patients undergoing surgery for degenerative scoliosis. METHODS Elderly patients 65 years and older undergoing a planned elective spinal surgery for correction of adult degenerative scoliosis were enrolled in this study. Preoperative cognition was assessed using the validated Saint Louis University Mental Status (SLUMS) examination. SLUMS comprises 11 questions, with a maximum score of 30 points. Mild cognitive impairment was defined as a SLUMS score between 21 and 26 points, while severe cognitive impairment was defined as a SLUMS score of ≤ 20 points. Normal cognition was defined as a SLUMS score of ≥ 27 points. Delirium was assessed daily using the Confusion Assessment Method (CAM) and rated as absent or present on the basis of CAM. The incidence of delirium was compared in patients with and without baseline cognitive impairment. RESULTS Twenty-two patients (18%) developed delirium postoperatively. Baseline demographics, including age, sex, comorbidities, and perioperative variables, were similar in patients with and without delirium. The length of in-hospital stay (mean 5.33 days vs 5.48 days) and 30-day hospital readmission rates (12.28% vs 12%) were similar between patients with and without delirium, respectively. Patients with preoperative cognitive impairment (i.e., a lower SLUMS score) had a higher incidence of postoperative delirium. One- and 2-year patient reported outcomes scores were similar in patients with and without delirium. CONCLUSIONS Cognitive impairment is a risk factor for the development of postoperative delirium. Postoperative delirium may be associated with decreased preoperative cognitive reserve. Cognitive impairment assessments should be considered in the preoperative evaluations of elderly patients prior to surgery.

  6. CDUCT-LaRC Status - Shear Layer Refraction and Noise Radiation

    NASA Technical Reports Server (NTRS)

    Nark, Douglas M.; Farassat, F.

    2006-01-01

    A proposed boundary condition accounting for shear layer effects within the Ffowcs Williams-Hawkings radiation module of the CDUCT-LaRC code is investigated. The development and numerical justification of the boundary condition formulation are reviewed. An initial assessment of the effectiveness of the shear layer correction is conducted through comparison with experimental data. Preliminary results indicate that the correction provides physically meaningful modifications of the baseline predicted directivity patterns. Trends of peak directivity steepening and shifting that appeared in predicted patterns were found to follow similar structures in measured data, particularly at higher radiation angles.

  7. Theory of post-block 2 VLBI observable extraction

    NASA Technical Reports Server (NTRS)

    Lowe, Stephen T.

    1992-01-01

    The algorithms used in the post-Block II fringe-fitting software called 'Fit' are described. The steps needed to derive the very long baseline interferometry (VLBI) charged-particle corrected group delay, phase delay rate, and phase delay (the latter without resolving cycle ambiguities) are presented beginning with the set of complex fringe phasors as a function of observation frequency and time. The set of complex phasors is obtained from the JPL/CIT Block II correlator. The output of Fit is the set of charged-particle corrected observables (along with ancillary information) in a form amenable to the software program 'Modest.'

  8. Training Needs and Evaluation of a Neuro-HIV Training Module for Non-Physician Healthcare Workers in Western Kenya

    PubMed Central

    Cettomai, Deanna; Kwasa, Judith; Birbeck, Gretchen L.; Price, Richard W.; Bukusi, Elizabeth A.; Meyer, Ana-Claire

    2011-01-01

    Background Recent efforts to improve neurological care in resource-limited settings have focused on providing training to non-physician healthcare workers. Methods A one-day neuro-HIV training module emphasizing HIV-associated dementia (HAD) and peripheral neuropathy was provided to 71 health care workers in western Kenya. Pre- and post-tests were administered to 55 participants. Results Mean age of participants was 29 years, 53% were clinical officers and 40% were nurses. Self-reported comfort was significantly higher for treating medical versus neurologic conditions (p<0.001). After training, participants identified more neuropathy etiologies (pre=5.6/9 possible correct etiologies; post=8.0/9; p<0.001). Only 4% of participants at baseline and 6% (p=0.31) post-training could correctly identify HAD diagnostic criteria, though there were fewer mis-identified criteria such as abnormal level of consciousness (pre=82%; post=43%; p<0.001) and hallucinations (pre=57%; post=15%; p<0.001). Conclusions Healthcare workers were more comfortable treating medical than neurological conditions. This training significantly improved knowledge about etiologies of neuropathy and decreased some misconceptions about HAD. PMID:21652049

  9. Smoothness of In vivo Spectral Baseline Determined by Mean Squared Error

    PubMed Central

    Zhang, Yan; Shen, Jun

    2013-01-01

    Purpose A nonparametric smooth line is usually added to spectral model to account for background signals in vivo magnetic resonance spectroscopy (MRS). The assumed smoothness of the baseline significantly influences quantitative spectral fitting. In this paper, a method is proposed to minimize baseline influences on estimated spectral parameters. Methods In this paper, the non-parametric baseline function with a given smoothness was treated as a function of spectral parameters. Its uncertainty was measured by root-mean-squared error (RMSE). The proposed method was demonstrated with a simulated spectrum and in vivo spectra of both short echo time (TE) and averaged echo times. The estimated in vivo baselines were compared with the metabolite-nulled spectra, and the LCModel-estimated baselines. The accuracies of estimated baseline and metabolite concentrations were further verified by cross-validation. Results An optimal smoothness condition was found that led to the minimal baseline RMSE. In this condition, the best fit was balanced against minimal baseline influences on metabolite concentration estimates. Conclusion Baseline RMSE can be used to indicate estimated baseline uncertainties and serve as the criterion for determining the baseline smoothness of in vivo MRS. PMID:24259436

  10. The Danish Organic Action Plan 2020: assessment method and baseline status of organic procurement in public kitchens.

    PubMed

    Sørensen, Nina N; Lassen, Anne D; Løje, Hanne; Tetens, Inge

    2015-09-01

    With political support from the Danish Organic Action Plan 2020, organic public procurement in Denmark is expected to increase. In order to evaluate changes in organic food procurement in Danish public kitchens, reliable methods are needed. The present study aimed to compare organic food procurement measurements by two methods and to collect and discuss baseline organic food procurement measurements from public kitchens participating in the Danish Organic Action Plan 2020. Comparison study measuring organic food procurement by applying two different methods, one based on the use of procurement invoices (the Organic Cuisine Label method) and the other on self-reported procurement (the Dogme method). Baseline organic food procurement status was based on organic food procurement measurements and background information from public kitchens. Public kitchens participating in the six organic food conversion projects funded by the Danish Organic Action Plan 2020 during 2012 and 2013. Twenty-six public kitchens (comparison study) and 345 public kitchens (baseline organic food procurement status). A high significant correlation coefficient was found between the two organic food procurement measurement methods (r=0·83, P<0·001) with measurements relevant for the baseline status. Mean baseline organic food procurement was found to be 24 % when including measurements from both methods. The results indicate that organic food procurement measurements by both methods were valid for the baseline status report of the Danish Organic Action Plan 2020. Baseline results in Danish public kitchens suggest there is room for more organic as well as sustainable public procurement in Denmark.

  11. Hypocalcaemia in patients with metastatic bone disease treated with denosumab.

    PubMed

    Body, Jean-Jacques; Bone, Henry G; de Boer, Richard H; Stopeck, Alison; Van Poznak, Catherine; Damião, Ronaldo; Fizazi, Karim; Henry, David H; Ibrahim, Toni; Lipton, Allan; Saad, Fred; Shore, Neal; Takano, Toshimi; Shaywitz, Adam J; Wang, Huei; Bracco, Oswaldo L; Braun, Ada; Kostenuik, Paul J

    2015-09-01

    This analysis was performed to further characterise treatment-emergent hypocalcaemia in patients with bone metastases receiving denosumab. Laboratory abnormalities and adverse events of hypocalcaemia in patients with metastatic bone disease were analysed using data from three identically designed phase 3 trials of subcutaneous denosumab 120 mg (n = 2841) versus intravenous zoledronic acid 4 mg (n = 2836). The overall incidence of laboratory events of hypocalcaemia grade ⩾ 2 was higher with denosumab (12.4%) than with zoledronic acid (5.3%). Hypocalcaemia events were primarily grade 2 in severity and usually occurred within the first 6 months of treatment. Patients who reported taking calcium and/or vitamin D supplements had a lower incidence of hypocalcaemia. Prostate cancer or small-cell lung cancer, reduced creatinine clearance and higher baseline bone turnover markers of urinary N-telopeptide of type I collagen (uNTx; > 50 versus ⩽ 50 nmol/mmol) and bone-specific alkaline phosphatase (BSAP; > 20.77 μg/L [median] versus ⩽ 20.77 μg/L) values were important risk factors for developing hypocalcaemia. The risk associated with increased baseline BSAP levels was greater among patients who had > 2 bone metastases at baseline versus those with ⩽ 2 bone metastases at baseline. Hypocalcaemia was more frequent with denosumab versus zoledronic acid, consistent with denosumab's greater antiresorptive effect. Low serum calcium levels and potential vitamin D deficiency should be corrected before initiating treatment with a potent osteoclast inhibitor, and corrected serum calcium levels should be monitored during treatment. Adequate calcium and vitamin D intake appears to substantially reduce the risk of hypocalcaemia. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Changes in Liver Volume in Patients with Chronic Hepatitis C Undergoing Antiviral Therapy.

    PubMed

    Fitzpatrick, Julie A; Kim, Jin Un; Cobbold, Jeremy F L; McPhail, Mark J W; Crossey, Mary M E; Bak-Bol, Aluel A; Zaky, Ashraf; Taylor-Robinson, Simon D

    2016-03-01

    Liver volumetric analysis has not been used to detect hepatic remodelling during antiviral therapy before. We measured liver volume (LV) changes on volumetric magnetic resonance imaging during hepatitis C antiviral therapy. 22 biopsy-staged patients (median [range] age 45(19-65) years; 9F, 13M) with chronic hepatitis C virus infection were studied. LV was measured at the beginning, end of treatment and 6 months post-treatment using 3D T1-weighted acquisition, normalised to patient weight. Liver outlines were drawn manually on 4 mm thick image slices and LV calculated. Inter-observer agreement was analysed. Patients were also assessed longitudinally using biochemical parameters and liver stiffness using Fibroscan™. Sustained viral response (SVR) was achieved in 13 patients with a mean baseline LV/kg of 0.022 (SD 0.004) L/kg. At the end of treatment, the mean LV/kg was 0.025 (SD 0.004, P = 0.024 cf baseline LV/kg) and 0.026 (SD 0.004, P = 0.008 cf baseline LV/kg) 6 months post-treatment (P = 0.030 cf baseline, P = 0.004). Body weight-corrected end of treatment LV change was significantly higher in patients with SVR compared to patients not attaining SVR (P = 0.050). End of treatment LV change was correlated to initial ALT (R (2) = 0.479, P = 0.037), but not APRI, AST, viral load or liver stiffness measurements. There was a correlation of 0.89 between observers for measured slice thickness. LV increased during anti-viral treatment, while the body weight-corrected LV increase persisted post-antiviral therapy and was larger in patients with SVR.

  13. Postseismic slip of 2011 Tohoku-oki Earthquake across the trench axis through long-term geodetic observations

    NASA Astrophysics Data System (ADS)

    Yamamoto, R.; Hino, R.; Kido, M.; Osada, Y.; Honsho, C.

    2017-12-01

    Since postseismic deformation across 2011 Tohoku-oki Earthquake is strongly affected by viscoelastic relaxation, it is difficult to identify postseismic slip from onshore (e.g. GNSS) and offshore (e.g. GPS-Acoustic: GPS-A) observations. To track postseismic slip directly, we installed acoustic ranging instruments across the axis of the central Japan Trench, off-Miyagi, near the region of large coseismic motion (>50 m) happened during 2011 Tohoku-oki Earthquake.Direct Path Ranging (DPR) measures two-way travel time between a pair of transponders settled on the seafloor. Baseline length can be obtained from calculating travel time and sound velocity which is corrected for time-varying temperature and pressure beforehand. We further made correction for the motion of acoustic elements due to attitude changes of the instruments. Baseline changes can be detected precisely by periodic ranging during observation.We have conducted observations during three times (2013, 2014 - 2015, and 2015 - 2016), and revealed that no significant shortenings across the trench axis took place. It follows that no shallow postseismic slip had occurred off-Miyagi, at least from 2013 to 2016. We examined the accuracy of baseline length measurements and can observed 1.0 ppm (1.0 mm for 1 km baseline) errors, which is small enough. Our results are consistent with the postseismic slip distribution model based on GPS-A observations.Acknowledgements: This research is supported by JSPS KAKENHI (26000002). The installation and recovery of instruments were executed during R/V Kairei (KR13-09; KR15-15), R/V Hakuho-maru (KH-13-05; KH-17-J02), R/V Shinsei-maru (KS-14-17; KS-15-03; KS-16-14).

  14. Effect of health education on trainee teachers' knowledge, attitudes, and first aid management of epilepsy: An interventional study.

    PubMed

    Eze, Christian N; Ebuehi, Olufunke M; Brigo, Francesco; Otte, Willem M; Igwe, Stanley C

    2015-12-01

    High rates of poor knowledge of, and negative attitudes towards people with epilepsy (PWE) are generally found among school teachers. Their first aid epilepsy management skills are poor. It remains unknown if this is different among trainee teachers and whether educational intervention might reduce these rates. We examined the effect of health education on the knowledge, attitudes, and first aid management of epilepsy on trainee teachers in Nigeria. Baseline data and socio-demographic determinants were collected from 226 randomly selected trainee teachers, at the Federal College of Education, Lagos, Nigeria, with self-administered questionnaires. They received a health intervention comprising an hour and half epilepsy lecture followed by a discussion. Baseline knowledge of, and attitudes towards PWE and their first aid epilepsy management skills were compared to post-interventional follow-up data collected twelve weeks later with similar questionnaires. At baseline the majority (61.9%) and largest proportion (44.2%) of respondents had negative attitudes and poor knowledge of epilepsy, respectively. The knowledge of, and attitudes towards epilepsy, and the first aid management skill increased in most respondents, post-intervention. The proportion of respondents with poor knowledge and negative attitudes dropped by 15.5% (p<0.0001) and 16.4% (p<0.0001) respectively. Correct knowledge concomitantly increased by 29.6% (p<0.0001) and good first aid management skills increased by 25.0% (p<0.0001) from baseline. Epilepsy health education could increase trainee teachers' knowledge of, and attitudes towards epilepsy and facilitate correct first aid management. This emphasizes the potential benefit of incorporating an epilepsy tailored intervention programme into teachers' training curricula. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  15. Comparison of precision orbit derived density estimates for CHAMP and GRACE satellites

    NASA Astrophysics Data System (ADS)

    Fattig, Eric Dale

    Current atmospheric density models cannot adequately represent the density variations observed by satellites in Low Earth Orbit (LEO). Using an optimal orbit determination process, precision orbit ephemerides (POE) are used as measurement data to generate corrections to density values obtained from existing atmospheric models. Densities obtained using these corrections are then compared to density data derived from the onboard accelerometers of satellites, specifically the CHAMP and GRACE satellites. This comparison takes two forms, cross correlation analysis and root mean square analysis. The densities obtained from the POE method are nearly always superior to the empirical models, both in matching the trends observed by the accelerometer (cross correlation), and the magnitudes of the accelerometer derived density (root mean square). In addition, this method consistently produces better results than those achieved by the High Accuracy Satellite Drag Model (HASDM). For satellites orbiting Earth that pass through Earth's upper atmosphere, drag is the primary source of uncertainty in orbit determination and prediction. Variations in density, which are often not modeled or are inaccurately modeled, cause difficulty in properly calculating the drag acting on a satellite. These density variations are the result of many factors; however, the Sun is the main driver in upper atmospheric density changes. The Sun influences the densities in Earth's atmosphere through solar heating of the atmosphere, as well as through geomagnetic heating resulting from the solar wind. Data are examined for fourteen hour time spans between November 2004 and July 2009 for both the CHAMP and GRACE satellites. This data spans all available levels of solar and geomagnetic activity, which does not include data in the elevated and high solar activity bins due to the nature of the solar cycle. Density solutions are generated from corrections to five different baseline atmospheric models, as well as nine combinations of density and ballistic coefficient correlated half-lives. These half-lives are varied among values of 1.8, 18, and 180 minutes. A total of forty-five sets of results emerge from the orbit determination process for all combinations of baseline density model and half-lives. Each time period is examined for both CHAMP and GRACE-A, and the results are analyzed. Results are averaged from all solutions periods for 2004--2007. In addition, results are averaged after binning according to solar and geomagnetic activity levels. For any given day in this period, a ballistic coefficient correlated half-life of 1.8 minutes yields the best correlation and root mean square values for both CHAMP and GRACE. For CHAMP, a density correlated half-life of 18 minutes is best for higher levels of solar and geomagnetic activity, while for lower levels 180 minutes is usually superior. For GRACE, 180 minutes is nearly always best. The three Jacchia-based atmospheric models yield very similar results. The CIRA 1972 or Jacchia 1971 models as baseline consistently produce the best results for both satellites, though results obtained for Jacchia-Roberts are very similar to the other Jacchia-based models. Data are examined in a similar manner for the extended solar minimum period during 2008 and 2009, albeit with a much smaller sampling of data. With the exception of some atypical results, similar combinations of half-lives and baseline atmospheric model produce the best results. A greater sampling of data will aid in characterizing density in a period of especially low solar activity. In general, cross correlation values for CHAMP and GRACE revealed that the POE method matched trends observed by the accelerometers very well. However, one period of time deviated from this trend for the GRACE-A satellite. Between late October 2005 and January 2006, correlations for GRACE-A were very low. Special examination of the surrounding months revealed the extent of time this period covered. Half-life and baseline model combinations that produced the best results during this time were similar to those during normal periods. Plotting these periods revealed very short period density variations in the accelerometer that could not be reproduced by the empirical models, HASDM, or the POE method. Finally, densities produced using precision orbit data for the GRACE-B satellite were shown to be nearly indistinguishable from those produced by GRACE-A. Plots of the densities produced for both satellites during the same time periods revealed this fact. Multiple days were examined covering all possible ranges of solar and geomagnetic activity. In addition, the period in which GRACE-A correlations were low was studied. No significant differences existed between GRACE-A and GRACE-B for all of the days examined.

  16. Priming effects under correct change detection and change blindness.

    PubMed

    Caudek, Corrado; Domini, Fulvio

    2013-03-01

    In three experiments, we investigated the priming effects induced by an image change on a successive animate/inanimate decision task. We studied both perceptual (Experiments 1 and 2) and conceptual (Experiment 3) priming effects, under correct change detection and change blindness (CB). Under correct change detection, we found larger positive priming effects on congruent trials for probes representing animate entities than for probes representing artifactual objects. Under CB, we found performance impairment relative to a "no-change" baseline condition. This inhibition effect induced by CB was modulated by the semantic congruency between the changed item and the probe in the case of probe images, but not for probe words. We discuss our results in the context of the literature on the negative priming effect. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Some direct and generalized effects of replacing an autistic man's echolalia with correct responses to questions.

    PubMed Central

    McMorrow, M J; Foxx, R M

    1986-01-01

    We extended the use of operant procedures to decrease immediate echolalia and increase the appropriate responding to questions of a 21-year-old autistic man. Three experiments were conducted in which the overall plan was to encourage the subject to remain quiet before, during, and after the presentation of questions and teach him to use environmental cues (i.e., word cards or a model's responses) to increase the likelihood of responding correctly. Multiple baseline designs demonstrated that echolalia was rapidly replaced with correct stimulus-specific responses. In addition, there were a variety of generalized improvements in the subject's verbal responses to questions. The procedures and results are contrasted to previous research in an attempt to explain the encouraging findings. PMID:3771422

  18. Detection and correction of laser induced breakdown spectroscopy spectral background based on spline interpolation method

    NASA Astrophysics Data System (ADS)

    Tan, Bing; Huang, Min; Zhu, Qibing; Guo, Ya; Qin, Jianwei

    2017-12-01

    Laser-induced breakdown spectroscopy (LIBS) is an analytical technique that has gained increasing attention because of many applications. The production of continuous background in LIBS is inevitable because of factors associated with laser energy, gate width, time delay, and experimental environment. The continuous background significantly influences the analysis of the spectrum. Researchers have proposed several background correction methods, such as polynomial fitting, Lorenz fitting and model-free methods. However, less of them apply these methods in the field of LIBS Technology, particularly in qualitative and quantitative analyses. This study proposes a method based on spline interpolation for detecting and estimating the continuous background spectrum according to its smooth property characteristic. Experiment on the background correction simulation indicated that, the spline interpolation method acquired the largest signal-to-background ratio (SBR) over polynomial fitting, Lorenz fitting and model-free method after background correction. These background correction methods all acquire larger SBR values than that acquired before background correction (The SBR value before background correction is 10.0992, whereas the SBR values after background correction by spline interpolation, polynomial fitting, Lorentz fitting, and model-free methods are 26.9576, 24.6828, 18.9770, and 25.6273 respectively). After adding random noise with different kinds of signal-to-noise ratio to the spectrum, spline interpolation method acquires large SBR value, whereas polynomial fitting and model-free method obtain low SBR values. All of the background correction methods exhibit improved quantitative results of Cu than those acquired before background correction (The linear correlation coefficient value before background correction is 0.9776. Moreover, the linear correlation coefficient values after background correction using spline interpolation, polynomial fitting, Lorentz fitting, and model-free methods are 0.9998, 0.9915, 0.9895, and 0.9940 respectively). The proposed spline interpolation method exhibits better linear correlation and smaller error in the results of the quantitative analysis of Cu compared with polynomial fitting, Lorentz fitting and model-free methods, The simulation and quantitative experimental results show that the spline interpolation method can effectively detect and correct the continuous background.

  19. A long baseline global stereo matching based upon short baseline estimation

    NASA Astrophysics Data System (ADS)

    Li, Jing; Zhao, Hong; Li, Zigang; Gu, Feifei; Zhao, Zixin; Ma, Yueyang; Fang, Meiqi

    2018-05-01

    In global stereo vision, balancing the matching efficiency and computing accuracy seems to be impossible because they contradict each other. In the case of a long baseline, this contradiction becomes more prominent. In order to solve this difficult problem, this paper proposes a novel idea to improve both the efficiency and accuracy in global stereo matching for a long baseline. In this way, the reference images located between the long baseline image pairs are firstly chosen to form the new image pairs with short baselines. The relationship between the disparities of pixels in the image pairs with different baselines is revealed by considering the quantized error so that the disparity search range under the long baseline can be reduced by guidance of the short baseline to gain matching efficiency. Then, the novel idea is integrated into the graph cuts (GCs) to form a multi-step GC algorithm based on the short baseline estimation, by which the disparity map under the long baseline can be calculated iteratively on the basis of the previous matching. Furthermore, the image information from the pixels that are non-occluded under the short baseline but are occluded for the long baseline can be employed to improve the matching accuracy. Although the time complexity of the proposed method depends on the locations of the chosen reference images, it is usually much lower for a long baseline stereo matching than when using the traditional GC algorithm. Finally, the validity of the proposed method is examined by experiments based on benchmark datasets. The results show that the proposed method is superior to the traditional GC method in terms of efficiency and accuracy, and thus it is suitable for long baseline stereo matching.

  20. Deriving site-specific clean-up criteria to protect ecological receptors (plants and soil invertebrates) exposed to metal or metalloid soil contaminants via the direct contact exposure pathway

    PubMed Central

    Checkai, Ron; Van Genderen, Eric; Sousa, José Paulo; Stephenson, Gladys; Smolders, Erik

    2014-01-01

    Soil contaminant concentration limits for the protection of terrestrial plants and soil invertebrates are commonly based on thresholds derived using data from laboratory ecotoxicity tests. A comprehensive assessment has been made for the derivation of ecological soil screening levels (Eco-SSL) in the United States; however, these limits are conservative because of their focus on high bioavailability scenarios. Here, we explain and evaluate approaches to soil limit derivation taken by 4 jurisdictions, 2 of which allow for correction of data for factors affecting bioavailability among soils, and between spiked and field-contaminated soils (Registration Evaluation Authorisation and Restriction of Chemicals [REACH] Regulation, European Union [EU], and the National Environment Protection Council [NEPC], Australia). Scientifically advanced features from these methods have been integrated into a newly developed method for deriving soil clean-up values (SCVs) within the context of site-specific baseline ecological risk assessment. Resulting site-specific SCVs that account for bioavailability may permit a greater residual concentration in soil when compared to generic screening limit concentrations (e.g., Eco-SSL), while still affording acceptable protection. Two choices for selecting the level of protection are compared (i.e., allowing higher effect levels per species, or allowing a higher percentile of species that are potentially unprotected). Implementation of this new method is presented for the jurisdiction of the United States, with a focus on metal and metalloid contaminants; however, the new method can be used in any jurisdiction. A case study for molybdate shows the large effect of bioavailability corrections and smaller effects of protection level choices when deriving SCVs. Integr Environ Assess Manag 2014;10:346–357. PMID:24470189

  1. A study examining the bias of albumin and albumin/creatinine ratio measurements in urine.

    PubMed

    Jacobson, Beryl E; Seccombe, David W; Katayev, Alex; Levin, Adeera

    2015-10-01

    The objective of the study was to examine the bias of albumin and albumin/creatinine (ACR) measurements in urine. Pools of normal human urine were augmented with purified human serum albumin to generate a series of 12 samples covering the clinical range of interest for the measurement of ACR. Albumin and creatinine concentrations in these samples were analyzed three times on each of 3 days by 24 accredited laboratories in Canada and the USA. Reference values (RV) for albumin measurements were assigned by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) comparative method and gravimetrically. Ten random urine samples (check samples) were analyzed as singlets and albumin and ACR values reported according to the routine practices of each laboratory. Augmented urine pools were shown to be commutable. Gravimetrically assigned target values were corrected for the presence of endogenous albumin using the LC-MS/MS comparative method. There was excellent agreement between the RVs as assigned by these two methods. All laboratory medians demonstrated a negative bias for the measurement of albumin in urine over the concentration range examined. The magnitude of this bias tended to decrease with increasing albumin concentrations. At baseline, only 10% of the patient ACR values met a performance limit of RV ± 15%. This increased to 84% and 86% following post-analytical correction for albumin and creatinine calibration bias, respectively. International organizations should take a leading role in the standardization of albumin measurements in urine. In the interim, accuracy based urine quality control samples may be used by clinical laboratories for monitoring the accuracy of their urinary albumin measurements.

  2. Assessing informed consent in an opioid relapse prevention study with adults under current or recent criminal justice supervision.

    PubMed

    Allen, Ashleigh A; Chen, Donna T; Bonnie, Richard J; Ko, Tomohiro M; Suratt, Colleen E; Lee, Joshua D; Friedmann, Peter D; Gordon, Michael; McDonald, Ryan; Murphy, Sean M; Boney, Tamara Y; Nunes, Edward V; O'Brien, Charles P

    2017-10-01

    Concerns persist that individuals with substance use disorders who are under community criminal justice supervision experience circumstances that might compromise their provision of valid, informed consent for research participation. These concerns include the possibilities that desire to obtain access to treatment might lead individuals to ignore important information about research participation, including information about risks, or that cognitive impairment associated with substance use might interfere with attending to important information. We report results from a consent quiz (CQ) administered in a multisite randomized clinical trial of long-acting naltrexone to prevent relapse to opioid use disorder among adults under community criminal justice supervision-a treatment option difficult to access by this population of individuals. Participants were required to answer all 11 items correctly before randomization. On average, participants answered 9.8 items correctly (89%) at baseline first attempt (n=306). At week 21 (n=212), participants scored 87% (9.5 items correct) without review. Performance was equivalent to, or better than, published results from other populations on a basic consent quiz instrument across multiple content domains. The consent quiz is an efficient method to screen for adequate knowledge of consent information as part of the informed consent process. Clinical researchers who are concerned about these issues should consider using a consent quiz with corrected feedback to enhance the informed consent process. Overall, while primarily useful as an educational tool, employing a CQ as part of the gateway to participation in research may be particularly important as the field continues to advance and tests novel experimental treatments with significant risks and uncertain potential for benefit. Copyright © 2017. Published by Elsevier Inc.

  3. Implementation of WHO multimodal strategy for improvement of hand hygiene: a quasi-experimental study in a Traditional Chinese Medicine hospital in Xi'an, China.

    PubMed

    Shen, Li; Wang, Xiaoqing; An, Junming; An, Jialu; Zhou, Ning; Sun, Lu; Chen, Hong; Feng, Lin; Han, Jing; Liu, Xiaorong

    2017-01-01

    Hand hygiene (HH) is an essential component for preventing and controlling of healthcare-associated infection (HAI), whereas compliance with HH among health care workers (HCWs) is frequently poor. This study aimed to assess compliance and correctness with HH before and after the implementation of a multimodal HH improvement strategy launched by the World Health Organization (WHO). A quasi-experimental study design including questionnaire survey generalizing possible factors affecting HH behaviors of HCWs and direct observation method was used to evaluate the effectiveness of WHO multimodal HH strategy in a hospital of Traditional Chinese Medicine. Multimodal HH improvement strategy was drawn up according to the results of questionnaire survey. Compliance and correctness with HH among HCWs were compared before and after intervention. Also HH practices for different indications based on WHO "My Five Moments for Hand Hygiene" were recorded. In total, 553 HCWs participated in the questionnaire survey and multimodal HH improvement strategy was developed based on individual, environment and management levels. A total of 5044 observations in 23 wards were recorded in this investigation. The rate of compliance and correctness with HH improved from 66.27% and 47.75% at baseline to 80.53% and 88.35% after intervention. Doctors seemed to have better compliance with HH after intervention (84.04%) than nurses and other HCWs (81.07% and 69.42%, respectively). When stratified by indication, compliance with HH improved for all indications after intervention ( P  < 0.05) except for "after body fluid exposure risk" and "after touching patient surroundings". Implementing the WHO multimodal HH strategy can significantly improve HH compliance and correctness among HCWs.

  4. Six-month trajectories of self-reported depressive symptoms in long-term care.

    PubMed

    McCusker, Jane; Cole, Martin G; Voyer, Philippe; Monette, Johanne; Champoux, Nathalie; Ciampi, Antonio; Vu, Minh; Belzile, Eric; Bai, Chun

    2016-01-01

    Depression is a common problem in long-term care (LTC) settings. We sought to characterize depression symptom trajectories over six months among older residents, and to identify resident characteristics at baseline that predict symptom trajectory. This study was a secondary analysis of data from a six-month prospective, observational, and multi-site study. Severity of depressive symptoms was assessed with the 15-item Geriatric Depression Scale (GDS) at baseline and with up to six monthly follow-up assessments. Participants were 130 residents with a Mini-Mental State Examination score of 15 or more at baseline and of at least two of the six monthly follow-up assessments. Individual resident GDS trajectories were grouped using hierarchical clustering. The baseline predictors of a more severe trajectory were identified using the Proportional Odds Model. Three clusters of depression symptom trajectory were found that described "lower," "intermediate," and "higher" levels of depressive symptoms over time (mean GDS scores for three clusters at baseline were 2.2, 4.9, and 9.0 respectively). The GDS scores in all groups were generally stable over time. Baseline predictors of a more severe trajectory were as follows: Initial GDS score of 7 or more, female sex, LTC residence for less than 12 months, and corrected visual impairment. The six-month course of depressive symptoms in LTC is generally stable. Most residents who experience a more severe symptom trajectory can be identified at baseline.

  5. Mark-recapture using tetracycline and genetics reveal record-high bear density

    USGS Publications Warehouse

    Peacock, E.; Titus, K.; Garshelis, D.L.; Peacock, M.M.; Kuc, M.

    2011-01-01

    We used tetracycline biomarking, augmented with genetic methods to estimate the size of an American black bear (Ursus americanus) population on an island in Southeast Alaska. We marked 132 and 189 bears that consumed remote, tetracycline-laced baits in 2 different years, respectively, and observed 39 marks in 692 bone samples subsequently collected from hunters. We genetically analyzed hair samples from bait sites to determine the sex of marked bears, facilitating derivation of sex-specific population estimates. We obtained harvest samples from beyond the study area to correct for emigration. We estimated a density of 155 independent bears/100 km2, which is equivalent to the highest recorded for this species. This high density appears to be maintained by abundant, accessible natural food. Our population estimate (approx. 1,000 bears) could be used as a baseline and to set hunting quotas. The refined biomarking method for abundance estimation is a useful alternative where physical captures or DNA-based estimates are precluded by cost or logistics. Copyright ?? 2011 The Wildlife Society.

  6. Exploring of PST-TBPM in Monitoring Dynamic Deformation of Steel Structure in Vibration

    NASA Astrophysics Data System (ADS)

    Chen, Mingzhi; Zhao, Yongqian; Hai, Hua; Yu, Chengxin; Zhang, Guojian

    2018-01-01

    In order to monitor the dynamic deformation of steel structure in the real-time, digital photography is used in this paper. Firstly, the grid method is used correct the distortion of digital camera. Then the digital cameras are used to capture the initial and experimental images of steel structure to obtain its relative deformation. PST-TBPM (photographing scale transformation-time baseline parallax method) is used to eliminate the parallax error and convert the pixel change value of deformation points into the actual displacement value. In order to visualize the deformation trend of steel structure, the deformation curves are drawn based on the deformation value of deformation points. Results show that the average absolute accuracy and relative accuracy of PST-TBPM are 0.28mm and 1.1‰, respectively. Digital photography used in this study can meet accuracy requirements of steel structure deformation monitoring. It also can warn the safety of steel structure and provide data support for managers’ safety decisions based on the deformation curves on site.

  7. A rapid detection method of Escherichia coli by surface enhanced Raman scattering

    NASA Astrophysics Data System (ADS)

    Tao, Feifei; Peng, Yankun; Xu, Tianfeng

    2015-05-01

    Conventional microbiological detection and enumeration methods are time-consuming, labor-intensive, and giving retrospective information. The objectives of the present work are to study the capability of surface enhanced Raman scattering (SERS) to detect Escherichia coli (E. coli) using the presented silver colloidal substrate. The obtained results showed that the adaptive iteratively reweighed Penalized Least Squares (airPLS) algorithm could effectively remove the fluorescent background from original Raman spectra, and Raman characteristic peaks of 558, 682, 726, 1128, 1210 and 1328 cm-1 could be observed stably in the baseline corrected SERS spectra of all studied bacterial concentrations. The detection limit of SERS could be determined to be as low as 0.73 log CFU/ml for E. coli with the prepared silver colloidal substrate. The quantitative prediction results using the intensity values of characteristic peaks were not good, with the correlation coefficients of calibration set and cross validation set of 0.99 and 0.64, respectively.

  8. Use of Global Meteorological Model to Correct for Stratified Tropospheric Delays in SAR Data: Application to Active Mexican Stratovolcanoes.

    NASA Astrophysics Data System (ADS)

    Pinel, V. M.; Doin, M.; de La Cruz-Reyna, S.; Hooper, A.

    2008-12-01

    Artefacts induced by temporal changes of water content within the tropospheric layer have long been recognised as the main limitation for the use of InSAR data in order to detect magma movement at depth beneath stratovolcanoes (Delacourt, 1998). Difficulty in discriminating between tropospheric artefacts and deformation induced by magma accumulation or withdrawal at depth is mainly due to the similarity of the expected signal centred on the volcanic edifice. However it is of prime importance to be able to detect magma storage which is the most reliable precursor for volcanic eruptions. We processed time series of InSAR data acquired by ENVISAT from December 2002 to August 2006 at Popocatépetl and Colima Volcano (Mexico) using both the Stanford method for persistent scatterers and a derived small baseline approach (Hooper, 2008). Tropospheric delays are estimated for each interferogram using temperature, pressure and water content profiles from the North American Regional Reanalysis (NARR), a global atmospheric model provided by the National Centers for Environmental Prediction. A strong seasonal effect is observed leading to maximum value for delays of 10 rad/km corresponding to 4 fringes on the volcano slopes. These delays are validated using the correlation between the wrapped phase and the elevation as well as spectrometer data acquired by the Medium Resolution Imaging System (MERIS) onboard on the ENVISAT platform. The tropospheric effect is removed from the wrapped phase which improves the unwrapping process. On Popocatépetl no significant deformations were observed. We could not detect any deep magma storage zone beneath Colima volcano, but its summit area exhibits a constant and almost linear subsidence of more than 1.5 cm/year mainly related to recent volcanic deposits loading. References: Delacourt, P. Briole and J. Achache, Tropospheric corrections of SAR interferograms with strong topography. Application to Etna. Geophys. Res. Lett., 25, 2849- 2852, 1998 Hooper, A., A Multi-Temporal InSAR Method Incorporating Both Persistent Scatterer and Small Baseline Approaches. Geophys. Res. Lett., 35, L 16302, doi:10.1029/2008GL034654, 2008.

  9. An Internet-based writing intervention for PTSD in veterans: A feasibility and pilot effectiveness trial.

    PubMed

    Krupnick, Janice L; Green, Bonnie L; Amdur, Richard; Alaoui, Adil; Belouali, Anas; Roberge, Erika; Cueva, David; Roberts, Miguel; Melnikoff, Elizabeth; Dutton, Mary Ann

    2017-07-01

    [Correction Notice: An Erratum for this article was reported in Vol 9(4) of Psychological Trauma: Theory, Research, Practice, and Policy (see record 2016-54154-001). In the article, the names of authors Adil Alaoui and Anas Belouali were misspelled as Adil Aloui and Anas Beloui respectively. All versions of this article have been corrected.] Objective: Veterans suffering from posttraumatic stress disorder (PTSD) may avoid or fail to follow through with a full course of face-to-face mental health treatment for a variety of reasons. We conducted a pilot effectiveness trial of an online intervention for veterans with current PTSD to determine the feasibility, safety, and preliminary effectiveness of an online writing intervention (i.e., Warriors Internet Recovery & EDucation [WIRED]) as an adjunct to face-to-face psychotherapy. Method: Veterans ( N = 34) who had served in Iraq or Afghanistan with current PTSD subsequent to deployment-related trauma were randomized to Veterans Affairs (VA) mental health treatment as usual (TAU) or to treatment as usual plus the online intervention (TAU + WIRED). All research participants were recruited from the Trauma Services Program, VA Medical Center, Washington, DC. They completed baseline assessments as well as assessments 12 weeks and 24 weeks after the baseline assessment. The online intervention consisted of therapist-guided writing, using principles of prolonged exposure and cognitive therapy. The intervention was adapted from an evidence-based treatment used in The Netherlands and Germany for individuals who had been exposed to nonmilitary traumas. Results: In addition to showing that the online intervention was both feasible to develop and implement, as well as being safe, the results showed preliminary evidence of the effectiveness of the TAU + WIRED intervention in this patient population, with particular evidence in reducing PTSD symptoms of hyperarousal. Conclusion: With minor modifications to enhance the therapeutic alliance, this intervention should be tested in a larger clinical trial to determine whether this method of online intervention might provide another alternative to face-to-face treatment for veterans with PTSD. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  10. Detection of atmospheric pressure loading using very long baseline interferometry measurements

    NASA Technical Reports Server (NTRS)

    Vandam, T. M.; Herring, T. A.

    1994-01-01

    Loading of the Earth by the temporal redistribution of global atmospheric mass is likely to displace the positions of geodetic monuments by tens of millimeters both vertically and horizontally. Estimates of these displacements are determined by convolving National Meteorological Center (NMC) global values of atmospheric surface pressure with Farrell's elastic Green's functions. An analysis of the distances between radio telescopes determined by very long baseline interferometry (VLBI) between 1984 and 1992 reveals that in many of the cases studied there is a significant contribution to baseline length change due to atmospheric pressure loading. Our analysis covers intersite distances of between 1000 and 10,000 km and is restricted to those baselines measured more than 100 times. Accounting for the load effects (after first removing a best fit slope) reduces the weighted root-mean-square (WRMS) scatter of the baseline length residuals on 11 of the 22 baselines investigated. The slight degradation observed in the WRMS scatter on the remaining baselines is largely consistent with the expected statistical fluctuations when a small correction is applied to a data set having a much larger random noise. The results from all baselines are consistent with approximately 60% of the computed pressure contribution being present in the VLBI length determinations. Site dependent coefficients determined by fitting local pressure to the theoretical radial displacement are found to reproduce the deformation caused by the regional pressure to within 25% for most inland sites. The coefficients are less reliable at near coastal and island stations.

  11. Toward Meaningful Outcomes in Teaching Conversation and Greeting Skills with Individuals with Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Hood, Stephanie A.; Luczynski, Kevin C.; Mitteer, Daniel R.

    2017-01-01

    We identified greeting and conversation deficits based on a parent interview and semistructured direct assessment for one child and two adolescents with autism spectrum disorder. We taught the greeting and conversation skills using behavioral skills training and within-session corrective feedback. A multiple baseline across conversation and…

  12. Classification of cultivation locations of Panax quinquefolius L samples using high performance liquid chromatography-electrospray ionization mass spectrometry and chemometric analysis

    USDA-ARS?s Scientific Manuscript database

    Panax quinquefolius L (P. quinquefolius L) samples grown in the United States and China were analyzed with high performance liquid chromatography-mass spectrometry (HPLC—MS). Prior to classification, the two-way datasets were subjected to pretreatment including baseline correction and retention tim...

  13. Classification of cultivation locations of panax quinquefolius L samples using high performance liquid chromatography-electrospray ionization mass spectrometry and chemometric analysis

    USDA-ARS?s Scientific Manuscript database

    Panax quinquefolius L (P. quinquefolius L) samples grown in the United States and China were analyzed with high performance liquid chromatography-mass spectrometry (HPLC—MS). Prior to classification, the two-way datasets were subjected to pretreatment including baseline correction and retention ti...

  14. Long-Term Follow-Up of Echolalia and Question Answering.

    ERIC Educational Resources Information Center

    Foxx, R. M.; Faw, Gerald D.

    1990-01-01

    A long-term followup (from 26 to 57 months) of echolalia and correct question-answering was conducted with six mentally retarded adult subjects identified from three previously published studies. Echolalia was lower than in baseline in 80.6 percent of the followups. Issues related to the study of maintenance are discussed. (Author/DB)

  15. A Reading Instruction Intervention Program for English-Language Learners Who Are Struggling Readers

    ERIC Educational Resources Information Center

    Tam, Kai Yung; Heward, William L.; Heng, Mary Anne

    2006-01-01

    We used a multiple baseline across students design to evaluate the effects of an intervention program consisting of vocabulary instruction, error correction, and fluency building on oral reading rate and comprehension of five English-language learners who were struggling readers in a primary school. During the first intervention condition (new…

  16. Comparison of baseline-referenced versus norm-referenced analytical approaches for in-theatre assessment of mild traumatic brain injury neurocognitive impairment.

    PubMed

    Haran, F Jay; Dretsch, Michael N; Slaboda, Jill C; Johnson, Dagny E; Adam, Octavian R; Tsao, Jack W

    2016-01-01

    To examine differences between the baseline-referenced and norm-referenced approaches for determining decrements in Automated Neuropsychological Assessment Metrics Version 4 TBI-MIL (ANAM) performance following mild traumatic brain injury (mTBI). ANAM data were reviewed for 616 US Service members, with 528 of this sample having experienced an mTBI and 88 were controls. Post-injury change scores were calculated for each sub-test: (1) normative change score = in-theater score - normative mean and (2) baseline change score = in-theater score - pre-deployment baseline. Reliable change cut-scores were applied to the change and the resulting frequency distributions were compared using McNemar tests. Receiver operator curves (ROC) using both samples (i.e. mTBI and control) were calculated for the change scores for each approach to determine the discriminate ability of the ANAM. There were no statistical differences, p < 0.05 (Bonferonni-Holm corrected), between the approaches. When the area under the curve for the ROCs were averaged across sub-tests, there were no significant differences between either the norm-referenced (0.65) or baseline-referenced (0.66) approaches, p > 0.05. Overall, the findings suggest there is no clear advantage of using the baseline-referenced approach over norm-referenced approach.

  17. Efficacy and safety of injection with poly-L-lactic acid compared with hyaluronic acid for correction of nasolabial fold: a randomized, evaluator-blinded, comparative study.

    PubMed

    Hyun, M Y; Lee, Y; No, Y A; Yoo, K H; Kim, M N; Hong, C K; Chang, S E; Won, C H; Kim, B J

    2015-03-01

    Hyaluronic acid (HA) fillers and poly-L-lactic acid (PLA) fillers are frequently used to correct facial wrinkles. To compare the efficacy and safety of a novel injectable poly-L-lactic acid (PLA) filler and a well-studied biphasic HA filler for the treatment of moderate to severe nasolabial folds. In this multicentre, randomized, evaluator-blinded, comparative study, subjects were randomized for injections with PLA or HA into both nasolabial folds. Efficacy was determined by calculating the change in Wrinkle Severity Rating Scale (WSRS) relative to baseline. Local safety was assessed by reported adverse events. At week 24, mean improvement in WSRS from baseline was 2.09 ± 0.68 for the PLA side and 1.54 ± 0.65 for the HA side. Both injections were well tolerated, and the adverse reactions were mild and transient in most cases. PLA provides noninferior efficacy compared with HA 6 months after being used to treat moderate to severe nasolabial folds. © 2014 British Association of Dermatologists.

  18. Constructed-response matching to sample and spelling instruction.

    PubMed Central

    Dube, W V; McDonald, S J; McIlvane, W J; Mackay, H A

    1991-01-01

    The development of interactive programmed instruction using a microcomputer as a teaching machine is described. The program applied a constructed-response matching-to-sample procedure to computer-assisted spelling instruction and review. On each trial, subjects were presented with a sample stimulus and a choice pool consisting of 10 individual letters. In initial training, sample stimuli were arrays of letters, and subjects were taught to construct identical arrays by touching the matching letters in the choice pool. After generalized constructed-response identity matching was established, pictures (line drawings) of common objects were presented as samples. At first, correct spelling was prompted by also presenting the printed name to be "copied" via identity matching; then the prompts were faded out. The program was implemented with 2 mentally retarded individuals. Assessment trials determined appropriate words for training. Correct spelling was established via the prompt-fading procedure; training trials were interspersed among baseline trials that reviewed and maintained spelling of previously learned words. As new words were learned, they were added to a cumulative baseline to generate an individualized review and practice battery for each subject. PMID:1890049

  19. Is prolongation of corrected QT interval associated with seizures induced by electroconvulsive therapy reduced by atropine sulfate?

    PubMed

    Suzuki, Yoko; Miyajima, Miho; Ohta, Katsuya; Yoshida, Noriko; Omoya, Rie; Fujiwara, Mayo; Watanabe, Takafumi; Okumura, Masaki; Yamazaki, Hiroaki; Shintaku, Masayuki; Murata, Issei; Ozaki, Shigeru; Sasaki, Takeshi; Nakamura, Mitsuru; Suwa, Hiroshi; Sasano, Tetsuo; Kawara, Tokuhiro; Matsuura, Masato; Matsushima, Eisuke

    2017-11-01

    Electrocardiogram abnormalities have been reported during electroconvulsive therapy (ECT). A corrected QT interval (QTc) prolongation indicates delayed ventricular repolarization, which can trigger ventricular arrhythmias such as torsade de pointes (TdP). We examined the QTc changes during generalized tonic-clonic seizures induced by ECT, and the effects of atropine sulfate on these QTc changes. We analyzed heart rate, QT interval, and QTc in 32 patients with depression who underwent ECT (25 women, 67.4 ± 8.7 years of age). The QTc from -30 to 0 seconds prestimulation was used as baseline, which was compared with QTc at 20-30 seconds and 140-150 seconds poststimulus onset. QTc was significantly prolonged at 20-30 seconds poststimulus, then significantly decreased at 140-150 seconds poststimulus, compared with baseline. QTc prolongation induced by ECT was significantly decreased by atropine sulfate. These data suggest that the risk of TdP may be enhanced by ECT. Further, the risk of cardiac ventricular arrhythmias, including TdP, may be reduced by administration of atropine sulfate. © 2017 Wiley Periodicals, Inc.

  20. Applying the intention-to-treat principle in practice: Guidance on handling randomisation errors.

    PubMed

    Yelland, Lisa N; Sullivan, Thomas R; Voysey, Merryn; Lee, Katherine J; Cook, Jonathan A; Forbes, Andrew B

    2015-08-01

    The intention-to-treat principle states that all randomised participants should be analysed in their randomised group. The implications of this principle are widely discussed in relation to the analysis, but have received limited attention in the context of handling errors that occur during the randomisation process. The aims of this article are to (1) demonstrate the potential pitfalls of attempting to correct randomisation errors and (2) provide guidance on handling common randomisation errors when they are discovered that maintains the goals of the intention-to-treat principle. The potential pitfalls of attempting to correct randomisation errors are demonstrated and guidance on handling common errors is provided, using examples from our own experiences. We illustrate the problems that can occur when attempts are made to correct randomisation errors and argue that documenting, rather than correcting these errors, is most consistent with the intention-to-treat principle. When a participant is randomised using incorrect baseline information, we recommend accepting the randomisation but recording the correct baseline data. If ineligible participants are inadvertently randomised, we advocate keeping them in the trial and collecting all relevant data but seeking clinical input to determine their appropriate course of management, unless they can be excluded in an objective and unbiased manner. When multiple randomisations are performed in error for the same participant, we suggest retaining the initial randomisation and either disregarding the second randomisation if only one set of data will be obtained for the participant, or retaining the second randomisation otherwise. When participants are issued the incorrect treatment at the time of randomisation, we propose documenting the treatment received and seeking clinical input regarding the ongoing treatment of the participant. Randomisation errors are almost inevitable and should be reported in trial publications. The intention-to-treat principle is useful for guiding responses to randomisation errors when they are discovered. © The Author(s) 2015.

  1. Background correction in separation techniques hyphenated to high-resolution mass spectrometry - Thorough correction with mass spectrometry scans recorded as profile spectra.

    PubMed

    Erny, Guillaume L; Acunha, Tanize; Simó, Carolina; Cifuentes, Alejandro; Alves, Arminda

    2017-04-07

    Separation techniques hyphenated with high-resolution mass spectrometry have been a true revolution in analytical separation techniques. Such instruments not only provide unmatched resolution, but they also allow measuring the peaks accurate masses that permit identifying monoisotopic formulae. However, data files can be large, with a major contribution from background noise and background ions. Such unnecessary contribution to the overall signal can hide important features as well as decrease the accuracy of the centroid determination, especially with minor features. Thus, noise and baseline correction can be a valuable pre-processing step. The methodology that is described here, unlike any other approach, is used to correct the original dataset with the MS scans recorded as profiles spectrum. Using urine metabolic studies as examples, we demonstrate that this thorough correction reduces the data complexity by more than 90%. Such correction not only permits an improved visualisation of secondary peaks in the chromatographic domain, but it also facilitates the complete assignment of each MS scan which is invaluable to detect possible comigration/coeluting species. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Effect of correction of aberration dynamics on chaos in human ocular accommodation.

    PubMed

    Hampson, Karen M; Cufflin, Matthew P; Mallen, Edward A H

    2013-11-15

    We used adaptive optics to determine the effect of monochromatic aberration dynamics on the level of chaos in the accommodation control system. Four participants viewed a stationary target while the dynamics of their aberrations were either left uncorrected, defocus was corrected, or all aberrations except defocus were corrected. Chaos theory analysis was used to discern changes in the accommodative microfluctuations. We found a statistically significant reduction in the chaotic nature of the accommodation microfluctuations during correction of defocus, but not when all aberrations except defocus were corrected. The Lyapunov exponent decreased from 0.71 ± 0.07 D/s (baseline) to 0.55 ± 0.03 D/s (correction of defocus fluctuations). As the reduction of chaos in physiological signals is indicative of stress to the system, the results indicate that for the participants included in this study, fluctuations in defocus have a more profound effect than those of the other aberrations. There were no changes in the power spectrum between experimental conditions. Hence chaos theory analysis is a more subtle marker of changes in the accommodation control system and will be of value in the study of myopia onset and progression.

  3. Blinded evaluation of the effects of hyaluronic acid filler injections on first impressions.

    PubMed

    Dayan, Steven H; Arkins, John P; Gal, Thomas J

    2010-11-01

    Facial appearance has profound influence on the first impression that is projected to others. To determine the effects that complete correction of the nasolabial folds (NLFs) with hyaluronic acid (HA) filler has on the first impression one makes. Twenty-two subjects received injections of HA filler into the NLFs. Photographs of the face in a relaxed pose were taken at baseline, optimal correction visit, and 4 weeks after optimal correction. Three hundred four blinded evaluators completed a survey rating first impression on various measures of success for each photo. In total, 5,776 first impressions were recorded, totaling 46,208 individual assessments of first impression. Our findings indicate a significant improvement in mean first impression in the categories of dating success, attractiveness, financial success, relationship success, athletic success, and overall first impression at the optimal correction visit. At 4 weeks after the optimal correction visit, significance was observed in all categories measured: social skills, academic performance, dating success, occupational success, attractiveness, financial success, relationship success, athletic success, and overall first impression. Full correction of the NLFs with HA filler significantly and positively influences the first impression an individual projects. © 2010 by the American Society for Dermatologic Surgery, Inc.

  4. Adherence to oral rehydration therapy among in-patient children aged 1-59 months with some or no dehydration.

    PubMed

    Migowa, A N; Gatinu, B; Nduati, R W

    2010-04-01

    To determine adherence to oral rehydration solution (ORS) among in-patients aged 1-59 months suffering from gastroenteritis and having some dehydration (SD) or no dehydration (ND) in two rural hospitals in Kenya. Children aged 1-59 months suffering from acute gastroenteritis with (SD) or (ND) were enrolled into the study, examined and medical records reviewed. On the second and third day of follow up, children were re-examined to ascertain hydration status and care-takers interviewed. Ninety-nine children were enrolled. Forty-five (75%) of the 60 children with SD received a correct prescription for ORS but only 12 (20%) received the correct amount. Among the 39 children with ND, 23 (59%) received a correct prescription for ORS, however only 16 (41%) received the correct amount. On the 3rd day, 9 (15%) of the 60 children with SD at baseline and 2 (5%) of the 39 with ND were classified as having SD. Four in five children with SD and 6 in 10 children with ND fail to receive the correct amounts of ORS.

  5. Efficiency of acidemia correction on intermittent versus continuous hemodialysis in acute methanol poisoning.

    PubMed

    Zakharov, Sergey; Pelclova, Daniela; Navratil, Tomas; Belacek, Jaromir; Latta, Jiri; Pisar, Michal; Rulisek, Jan; Leps, Jiri; Zidek, Pavel; Kucera, Cyril; Bocek, Robert; Mazur, Miroslav; Belik, Zdenek; Chalupa, Josef; Talafa, Viktor; Kodras, Kamil; Nalos, Daniel; Sedlak, Ctirad; Senkyrik, Michal; Smid, Jan; Salek, Tomas; Roberts, Darren M; Hovda, Knut Erik

    2017-02-01

    Acidemia is a marker of prognosis in methanol poisoning, as well as compounding formate-induced cytotoxicity. Prompt correction of acidemia is a key treatment of methanol toxicity and methods to optimize this are poorly defined. We studied the efficiency of acidemia correction by intermittent hemodialysis (IHD) and continuous renal replacement therapy (CRRT) in a mass outbreak of methanol poisoning. The study was designed as observational cohort study. The mean time for an increase of 1 mmol/L HCO 3 - , 0.01 unit arterial blood pH, and the total time for correction of HCO 3 - were determined in IHD- and CRRT-treated patients. Data were obtained from 18 patients treated with IHD and 13 patients treated with CRRT. At baseline, CRRT group was more acidemic than IHD group (mean arterial pH 6.79 ± 0.10 versus 7.05 ± 0.10; p = 0.001). No association was found between the rate of acidemia correction and age, weight, serum methanol, lactate, formate, and glucose on admission. The time to HCO 3 - correction correlated with arterial blood pH (r= -0.511; p = 0.003) and creatinine (r = 0.415; p = 0.020). There was association between the time to HCO 3 - correction and dialysate/effluent and blood flow rates (r= -0.738; p < 0.001 and r= -0.602; p < 0.001, correspondingly). The mean time for HCO 3 - to increase by 1 mmol/L was 12 ± 2 min for IHD versus 34 ± 8 min for CRRT (p < 0.001), and the mean time for arterial blood pH to increase 0.01 was 7 ± 1 mins for IHD versus 11 ± 4 min for CRRT (p = 0.024). The mean increase in HCO 3 - was 5.67 ± 0.90 mmol/L/h for IHD versus 2.17 ± 0.74 mmol/L/h for CRRT (p < 0.001). Our study supports the superiority of IHD over CRRT in terms of the rate of acidemia correction.

  6. Reconsidering Cluster Bias in Multilevel Data: A Monte Carlo Comparison of Free and Constrained Baseline Approaches.

    PubMed

    Guenole, Nigel

    2018-01-01

    The test for item level cluster bias examines the improvement in model fit that results from freeing an item's between level residual variance from a baseline model with equal within and between level factor loadings and between level residual variances fixed at zero. A potential problem is that this approach may include a misspecified unrestricted model if any non-invariance is present, but the log-likelihood difference test requires that the unrestricted model is correctly specified. A free baseline approach where the unrestricted model includes only the restrictions needed for model identification should lead to better decision accuracy, but no studies have examined this yet. We ran a Monte Carlo study to investigate this issue. When the referent item is unbiased, compared to the free baseline approach, the constrained baseline approach led to similar true positive (power) rates but much higher false positive (Type I error) rates. The free baseline approach should be preferred when the referent indicator is unbiased. When the referent assumption is violated, the false positive rate was unacceptably high for both free and constrained baseline approaches, and the true positive rate was poor regardless of whether the free or constrained baseline approach was used. Neither the free or constrained baseline approach can be recommended when the referent indicator is biased. We recommend paying close attention to ensuring the referent indicator is unbiased in tests of cluster bias. All Mplus input and output files, R, and short Python scripts used to execute this simulation study are uploaded to an open access repository.

  7. Reconsidering Cluster Bias in Multilevel Data: A Monte Carlo Comparison of Free and Constrained Baseline Approaches

    PubMed Central

    Guenole, Nigel

    2018-01-01

    The test for item level cluster bias examines the improvement in model fit that results from freeing an item's between level residual variance from a baseline model with equal within and between level factor loadings and between level residual variances fixed at zero. A potential problem is that this approach may include a misspecified unrestricted model if any non-invariance is present, but the log-likelihood difference test requires that the unrestricted model is correctly specified. A free baseline approach where the unrestricted model includes only the restrictions needed for model identification should lead to better decision accuracy, but no studies have examined this yet. We ran a Monte Carlo study to investigate this issue. When the referent item is unbiased, compared to the free baseline approach, the constrained baseline approach led to similar true positive (power) rates but much higher false positive (Type I error) rates. The free baseline approach should be preferred when the referent indicator is unbiased. When the referent assumption is violated, the false positive rate was unacceptably high for both free and constrained baseline approaches, and the true positive rate was poor regardless of whether the free or constrained baseline approach was used. Neither the free or constrained baseline approach can be recommended when the referent indicator is biased. We recommend paying close attention to ensuring the referent indicator is unbiased in tests of cluster bias. All Mplus input and output files, R, and short Python scripts used to execute this simulation study are uploaded to an open access repository. PMID:29551985

  8. [Comparative study on two total intravenous anesthesia techniques in complex spine surgery].

    PubMed

    Meng, Xiu-li; Wang, Li-wei; Zhou, Yang; Ma, Yue; Guo, Xiang-yang

    2013-06-18

    To compare anesthesia profiles of target-controlled infusion (TCI) and manual-controlled infusion (MCI) of propofol and remifentanil in kyphosis correction or scoliosis correction surgery, in which intraoperative spinal cord monitoring was employed. In the study, 160 patients scheduled for kyphosis correction surgery or scoliosis correction were enrolled and randomly allocated into 2 groups, group TCI and group MCI. In group TCI, induction and maintenance of general anesthesia were carried out by target-controlled infusion of propofol and remifentanil. Marsh and Minto, three-compartment pharmacokinetic models for propofol and remifentanil were used respectively. In group MCI, the patients received propofol and remifentanil by conventional dose-weight infusion method. Muscle relaxants were only applied for ease of induction. In both the groups, anesthesia depth was monitored by bispectral index (BIS), and the change of hemodynamic parameters was kept in the range of 20% of the baseline. The control convenience of anesthesia depth and change amplitude of BIS in the main steps of the procedure were compared. The total amounts of propofol and remifentanil, influence on the hemodynamics, influence on the successful rates of somatosensory evoked potentials (SSEPs) and motor evoked potentials (MEPs) and electromyography (EMG) were compared too. The time of pump regulation in group TCI was significantly less than in group MCI (P<0.05). The BIS fluctuation in the main steps of the procedure was significantly smaller in Group TCI than in group MCI (P<0.05). There was no significant difference in the amounts of propofol and remifentanil(P=0.158 and P=0.168). The time to awake (P=0.972) and time to extubation (P=0.944) had no significant difference. The successful rates of SSEPs and MEPs had no significant difference between groups TCI amd MCI (P>0.05). Both TCI and MCI can offer practical anesthesia for spinal deformity correction surgery. TCI has the advantage in keeping smooth and steady depth of anesthesia.

  9. Attaining genetic height potential: Analysis of height outcomes from the ANSWER Program in children treated with growth hormone over 5 years.

    PubMed

    Ross, Judith L; Lee, Peter A; Gut, Robert; Germak, John

    2015-12-01

    This study aimed to assess attainment of genetic height potential after long-term growth hormone (GH) treatment in GH-naïve children diagnosed with isolated growth hormone deficiency (IGHD), multiple pituitary hormone deficiency (MPHD), born small for gestational age (SGA), or idiopathic short stature (ISS) enrolled in the American Norditropin® Web-enabled Research (ANSWER) Program. Children with IGHD (n=2884), MPHD (n=200), SGA (n=481), or ISS (n=733) with baseline height standard deviation score (HSDS)≤-2 were assessed over 5 years of GH treatment for mean HSDS, change in HSDS (ΔHSDS), and corrected HSDS (HSDS-target HSDS). Mean HSDS and corrected HSDS significantly increased to close to target height across all diagnostic groups after 5 years of GH treatment (P<0.0001). ∆HSDS at year 5 increased for all groups (IGHD: 1.8; MPHD: 2.1; SGA: 1.8; ISS: 1.6). Among patients who continued GH for 5 years, mean insulin-like growth factor-I (IGF-I) SDS increased to within normal range across all groups. Body mass index (BMI) SDS remained relatively stable in all diagnostic groups. Bone age (BA) increased, and the mean BA to chronological age (BA/CA) ratio reached or approached 1 across diagnostic groups over 5 years of GH treatment. Long-term GH therapy resulted in a significant increase in mean HSDS and corrected HSDS from baseline values in all diagnostic groups. The observed increase in mean corrected HSDS is consistent with growth that approached the patients' genetic height potential, although complete height gains will be evaluated at the attainment of final height. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Axis-free correction of astigmatism using bifocal soft contact lenses.

    PubMed

    Leube, Alexander; Kovats, Imre; Wahl, Siegfried; Sickenberger, Wolfgang

    2017-12-01

    Pilot study to investigate the feasibility of an axis-free correction approach of regular astigmatism using soft, bifocal contact lenses (CL). The investigation covers an optical simulation and a pilot study for the assessment of visual performance (over refraction OR, monocular visual acuity VA). The power of the two zones was adjusted according to the power of the astigmatic meridians, individually. Subjective performance was assessed in 30 participants with a mean horizontal cylindrical component of J 0 =- 0.65±1.29 D (cylinder from -0.75 to -4.00 DC). OR and VA were measured directly after fitting the CL, after one hour and after 5days (3FUP). Evaluating the modulation transfer function, CL increased the Strehl ratio by 10% and the transferred spatial frequency was improved from 6.6 cpd to 21.3 cpd. Analysis of Sturm's interval revealed a residual astigmatism of D Ast =0.73 D. OR revealed a statistically significant reduction of spherical error between baseline and all follow up (ΔM=-2.14 D, p<0.001) and between the J 0 from baseline to 3FUP (ΔJ 0 =-0.46 D, p=0.04). Wearing the CL for 5days did not result in a significant difference of VA (ΔVA 3FUP =+0.01 logMAR, p=0.99). Axis-free correction of astigmatism using bifocal CL resulted in reasonable performance based on computer simulation. Participants showed no clinically reduced visual acuity or contrast sensitivity. Further clinical studies are needed to show if this approach provides a good alternative to conventional astigmatic correction. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. [Changes of brain function and cognitive function after carotid artery stenting].

    PubMed

    Lu, Z X; Deng, G; Wei, H L; Zhao, G F; Wen, L Z; Chen, X

    2017-10-24

    Objective: To investigate the effect of carotid artery stenting(CAS) on cognitive function and brain function based on changes of a battery of neuropsychological tests and magnetic resonance imaging. Methods: Thirty-three patients were included with 17 in the stent-placement group and 16 in the control group (receiving medical treatment), among whom, the unilateral or bilateral severe internal carotid artery stenosis was confirmed by cerebral vascular angiography in the department of Interventional Radiology and Vascular Surgery of Zhongda Hospital Southeast University from June 2015 to September 2016.Neuropsychological tests and rest-state blood oxygenation level dependent fMRI were performed at the baseline and six months follow-up.The baseline characteristics and follow-up changes were compared in each group. Results: The overall cognitive function of the stent-placement group was statistically significantly improved ( P <0.05) compared with control group, mainly in the executive function, memory, attention and other aspects.The value of amplitude of low-frequency fluctuation(ALFF) showed statistically significant increase ( P <0.05, Alphasim correction) in left prefrontal cortex ( t =5.861 3, P <0.05), the somatosensory association cortex in left superior parietal lobe( t =5.601 2, P <0.05) and bilateral motor cortical area in posterior frontal lobe ( t =5.288 5, P <0.05). The ALFF showed statistically significant decrease ( P <0.05, Alphasim correction) in left retrosplenial cingulate cortex( t =-5.590 4, P <0.05), left insular cortex ( t =-6.340 8, P <0.05), right insular cortex ( t =-8.129 9, P <0.05) and left dorsal anterior cingulate cortex ( t =-5.584 8, P <0.05). There was no statistically significant difference ( P >0.05, Alphasim correction)between baseline and follow-up results in control group.Besides, the ALFF changes of the left insular cortex ( r =-0.591, P =0.033) and bilateral motor cortical area ( r =-0.659, P =0.014) were negatively correlated with auditory verb learning test (AVLT) score changes.The ALFF change of bilateral motor cortical area was negatively correlated with the AVLT-delay score change ( r =-0.588, P =0.034). And the ALFF change on right insular cortex and the frontal assessment battery (FAB) score change was positively correlated ( r =0.638, P =0.025). Conclusions: The overall cognitive function of patients with carotid artery stenosis significantly improve after CAS compared with medical treatment.The change of ALFF value in related brain area is also statistically significant.ALFF Change most in area of Default Mode Network may suggest a mechanism of postoperative neurological recovery in patients with carotid artery stenosis.

  12. Prevalence and incidence of presbyopia in urban Southern China.

    PubMed

    Han, Xiaotong; Lee, Pei Ying; Keel, Stuart; He, Mingguang

    2018-01-24

    To investigate the prevalence and incidence of presbyopia in an urban Chinese population. 1817 subjects aged ≥35 years were identified by random cluster sampling in Yuexiu District, Guangzhou, China, at baseline in 2008, and all were invited for the follow-up examination in 2014. Distance and near visual acuity (VA) tests, as well as non-cycloplegic automated refraction were performed at each examination as per standardised protocol. Participants with presenting near VA ≤20/40 were further tested with add power at a standard distance of 40 cm to obtain their best-corrected near VA. Functional presbyopia was defined as near VA under presenting distance refraction correction of <20/50 and could be improved by at least one line with add power. A total of 1191 (83.5% of the 2014 follow-up) participants were included in the current analysis with a mean (SD) age of 50.4 (9.7) years, and 52.9% were female. Prevalence of functional presbyopia at baseline was 25.2% (95% CI 21.5 to 28.9) and the 6-year incidence was 42.8% (95% CI 39.4 to 50.1). Older and more hyperopic subjects had both higher prevalence and incidence of presbyopia (P<0.001). Average presbyopic correction coverage (PCC) was 87.7% at baseline and was significantly lower in myopic participants (P=0.006). Prevalence of functional presbyopia in urban China is relatively lower along with a higher PCC compared with previous population-based rural cohorts. We identified a high presbyopia incidence, and further studies are needed to understand longitudinal presbyopia progression as well as the urban-rural gap in presbyopia to throw light on future strategic planning. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Phase correction for ALMA. Investigating water vapour radiometer scaling: The long-baseline science verification data case study

    NASA Astrophysics Data System (ADS)

    Maud, L. T.; Tilanus, R. P. J.; van Kempen, T. A.; Hogerheijde, M. R.; Schmalzl, M.; Yoon, I.; Contreras, Y.; Toribio, M. C.; Asaki, Y.; Dent, W. R. F.; Fomalont, E.; Matsushita, S.

    2017-09-01

    The Atacama Large millimetre/submillimetre Array (ALMA) makes use of water vapour radiometers (WVR), which monitor the atmospheric water vapour line at 183 GHz along the line of sight above each antenna to correct for phase delays introduced by the wet component of the troposphere. The application of WVR derived phase corrections improve the image quality and facilitate successful observations in weather conditions that were classically marginal or poor. We present work to indicate that a scaling factor applied to the WVR solutions can act to further improve the phase stability and image quality of ALMA data. We find reduced phase noise statistics for 62 out of 75 datasets from the long-baseline science verification campaign after a WVR scaling factor is applied. The improvement of phase noise translates to an expected coherence improvement in 39 datasets. When imaging the bandpass source, we find 33 of the 39 datasets show an improvement in the signal-to-noise ratio (S/N) between a few to 30 percent. There are 23 datasets where the S/N of the science image is improved: 6 by <1%, 11 between 1 and 5%, and 6 above 5%. The higher frequencies studied (band 6 and band 7) are those most improved, specifically datasets with low precipitable water vapour (PWV), <1 mm, where the dominance of the wet component is reduced. Although these improvements are not profound, phase stability improvements via the WVR scaling factor come into play for the higher frequency (>450 GHz) and long-baseline (>5 km) observations. These inherently have poorer phase stability and are taken in low PWV (<1 mm) conditions for which we find the scaling to be most effective. A promising explanation for the scaling factor is the mixing of dry and wet air components, although other origins are discussed. We have produced a python code to allow ALMA users to undertake WVR scaling tests and make improvements to their data.

  14. Intra-individual variation in urinary iodine concentration: effect of statistical correction on population distribution using seasonal three-consecutive-day spot urine in children

    PubMed Central

    Ji, Xiaohong; Liu, Peng; Sun, Zhenqi; Su, Xiaohui; Wang, Wei; Gao, Yanhui; Sun, Dianjun

    2016-01-01

    Objective To determine the effect of statistical correction for intra-individual variation on estimated urinary iodine concentration (UIC) by sampling on 3 consecutive days in four seasons in children. Setting School-aged children from urban and rural primary schools in Harbin, Heilongjiang, China. Participants 748 and 640 children aged 8–11 years were recruited from urban and rural schools, respectively, in Harbin. Primary and secondary outcome measures The spot urine samples were collected once a day for 3 consecutive days in each season over 1 year. The UIC of the first day was corrected by two statistical correction methods: the average correction method (average of days 1, 2; average of days 1, 2 and 3) and the variance correction method (UIC of day 1 corrected by two replicates and by three replicates). The variance correction method determined the SD between subjects (Sb) and within subjects (Sw), and calculated the correction coefficient (Fi), Fi=Sb/(Sb+Sw/di), where di was the number of observations. The UIC of day 1 was then corrected using the following equation: Results The variance correction methods showed the overall Fi was 0.742 for 2 days’ correction and 0.829 for 3 days’ correction; the values for the seasons spring, summer, autumn and winter were 0.730, 0.684, 0.706 and 0.703 for 2 days’ correction and 0.809, 0.742, 0.796 and 0.804 for 3 days’ correction, respectively. After removal of the individual effect, the correlation coefficient between consecutive days was 0.224, and between non-consecutive days 0.050. Conclusions The variance correction method is effective for correcting intra-individual variation in estimated UIC following sampling on 3 consecutive days in four seasons in children. The method varies little between ages, sexes and urban or rural setting, but does vary between seasons. PMID:26920442

  15. Optimisation of reconstruction--reprojection-based motion correction for cardiac SPECT.

    PubMed

    Kangasmaa, Tuija S; Sohlberg, Antti O

    2014-07-01

    Cardiac motion is a challenging cause of image artefacts in myocardial perfusion SPECT. A wide range of motion correction methods have been developed over the years, and so far automatic algorithms based on the reconstruction--reprojection principle have proved to be the most effective. However, these methods have not been fully optimised in terms of their free parameters and implementational details. Two slightly different implementations of reconstruction--reprojection-based motion correction techniques were optimised for effective, good-quality motion correction and then compared with each other. The first of these methods (Method 1) was the traditional reconstruction-reprojection motion correction algorithm, where the motion correction is done in projection space, whereas the second algorithm (Method 2) performed motion correction in reconstruction space. The parameters that were optimised include the type of cost function (squared difference, normalised cross-correlation and mutual information) that was used to compare measured and reprojected projections, and the number of iterations needed. The methods were tested with motion-corrupt projection datasets, which were generated by adding three different types of motion (lateral shift, vertical shift and vertical creep) to motion-free cardiac perfusion SPECT studies. Method 2 performed slightly better overall than Method 1, but the difference between the two implementations was small. The execution time for Method 2 was much longer than for Method 1, which limits its clinical usefulness. The mutual information cost function gave clearly the best results for all three motion sets for both correction methods. Three iterations were sufficient for a good quality correction using Method 1. The traditional reconstruction--reprojection-based method with three update iterations and mutual information cost function is a good option for motion correction in clinical myocardial perfusion SPECT.

  16. Development of a practical image-based scatter correction method for brain perfusion SPECT: comparison with the TEW method.

    PubMed

    Shidahara, Miho; Watabe, Hiroshi; Kim, Kyeong Min; Kato, Takashi; Kawatsu, Shoji; Kato, Rikio; Yoshimura, Kumiko; Iida, Hidehiro; Ito, Kengo

    2005-10-01

    An image-based scatter correction (IBSC) method was developed to convert scatter-uncorrected into scatter-corrected SPECT images. The purpose of this study was to validate this method by means of phantom simulations and human studies with 99mTc-labeled tracers, based on comparison with the conventional triple energy window (TEW) method. The IBSC method corrects scatter on the reconstructed image I(mub)AC with Chang's attenuation correction factor. The scatter component image is estimated by convolving I(mub)AC with a scatter function followed by multiplication with an image-based scatter fraction function. The IBSC method was evaluated with Monte Carlo simulations and 99mTc-ethyl cysteinate dimer SPECT human brain perfusion studies obtained from five volunteers. The image counts and contrast of the scatter-corrected images obtained by the IBSC and TEW methods were compared. Using data obtained from the simulations, the image counts and contrast of the scatter-corrected images obtained by the IBSC and TEW methods were found to be nearly identical for both gray and white matter. In human brain images, no significant differences in image contrast were observed between the IBSC and TEW methods. The IBSC method is a simple scatter correction technique feasible for use in clinical routine.

  17. New decoding methods of interleaved burst error-correcting codes

    NASA Astrophysics Data System (ADS)

    Nakano, Y.; Kasahara, M.; Namekawa, T.

    1983-04-01

    A probabilistic method of single burst error correction, using the syndrome correlation of subcodes which constitute the interleaved code, is presented. This method makes it possible to realize a high capability of burst error correction with less decoding delay. By generalizing this method it is possible to obtain probabilistic method of multiple (m-fold) burst error correction. After estimating the burst error positions using syndrome correlation of subcodes which are interleaved m-fold burst error detecting codes, this second method corrects erasure errors in each subcode and m-fold burst errors. The performance of these two methods is analyzed via computer simulation, and their effectiveness is demonstrated.

  18. Variable selection based near infrared spectroscopy quantitative and qualitative analysis on wheat wet gluten

    NASA Astrophysics Data System (ADS)

    Lü, Chengxu; Jiang, Xunpeng; Zhou, Xingfan; Zhang, Yinqiao; Zhang, Naiqian; Wei, Chongfeng; Mao, Wenhua

    2017-10-01

    Wet gluten is a useful quality indicator for wheat, and short wave near infrared spectroscopy (NIRS) is a high performance technique with the advantage of economic rapid and nondestructive test. To study the feasibility of short wave NIRS analyzing wet gluten directly from wheat seed, 54 representative wheat seed samples were collected and scanned by spectrometer. 8 spectral pretreatment method and genetic algorithm (GA) variable selection method were used to optimize analysis. Both quantitative and qualitative model of wet gluten were built by partial least squares regression and discriminate analysis. For quantitative analysis, normalization is the optimized pretreatment method, 17 wet gluten sensitive variables are selected by GA, and GA model performs a better result than that of all variable model, with R2V=0.88, and RMSEV=1.47. For qualitative analysis, automatic weighted least squares baseline is the optimized pretreatment method, all variable models perform better results than those of GA models. The correct classification rates of 3 class of <24%, 24-30%, >30% wet gluten content are 95.45, 84.52, and 90.00%, respectively. The short wave NIRS technique shows potential for both quantitative and qualitative analysis of wet gluten for wheat seed.

  19. Correlations of Apparent Cellulose Crystallinity Determined by XRD, NMR, IR, Raman, and SFG Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, David K; Lee, Christopher; Dazen, Kevin

    2015-07-04

    Although the cellulose crystallinity index (CI) is used widely, its limitations have not been adequately described. In this study, the CI values of a set of reference samples were determined from X-ray diffraction (XRD), nuclear magnetic resonance (NMR), and infrared (IR), Raman, and vibrational sum frequency generation (SFG) spectroscopies. The intensities of certain crystalline peaks in IR, Raman, and SFG spectra positively correlated with the amount of crystalline cellulose in the sample, but the correlation with XRD was nonlinear as a result of fundamental differences in detection sensitivity to crystalline cellulose and improper baseline corrections for amorphous contributions. It ismore » demonstrated that the intensity and shape of the XRD signal is affected by both the amount of crystalline cellulose and crystal size, which makes XRD analysis complicated. It is clear that the methods investigated show the same qualitative trends for samples, but the absolute CI values differ depending on the determination method. This clearly indicates that the CI, as estimated by different methods, is not an absolute value and that for a given set of samples the CI values can be compared only as a qualitative measure.« less

  20. Correlations of Apparent Cellulose Crystallinity Determined by XRD, NMR, IR, Raman, and SFG Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Christopher M; Dazen, Kevin; Kafle, Kabindra

    2015-01-01

    Although the cellulose crystallinity index (CI) is used widely, its limitations have not been adequately described. In this study, the CI values of a set of reference samples were determined from X-ray diffraction (XRD), nuclear magnetic resonance (NMR), and infrared (IR), Raman, and vibrational sum frequency generation (SFG) spectroscopies. The intensities of certain crystalline peaks in IR, Raman, and SFG spectra positively correlated with the amount of crystalline cellulose in the sample, but the correlation with XRD was nonlinear as a result of fundamental differences in detection sensitivity to crystalline cellulose and improper baseline corrections for amorphous contributions. It ismore » demonstrated that the intensity and shape of the XRD signal is affected by both the amount of crystalline cellulose and crystal size, which makes XRD analysis complicated. It is clear that the methods investigated show the same qualitative trends for samples, but the absolute CI values differ depending on the determination method. This clearly indicates that the CI, as estimated by different methods, is not an absolute value and that for a given set of samples the CI values can be compared only as a qualitative measure.« less

  1. The Natural History of the Progression of Atrophy Secondary to Stargardt Disease (ProgStar) Studies: Design and Baseline Characteristics: ProgStar Report No. 1.

    PubMed

    Strauss, Rupert W; Ho, Alex; Muñoz, Beatriz; Cideciyan, Artur V; Sahel, José-Alain; Sunness, Janet S; Birch, David G; Bernstein, Paul S; Michaelides, Michel; Traboulsi, Elias I; Zrenner, Eberhart; Sadda, SriniVas; Ervin, Ann-Margret; West, Sheila; Scholl, Hendrik P N

    2016-04-01

    To describe the design and baseline characteristics of patients enrolled into 2 natural history studies of Stargardt disease (STGD1). Multicenter retrospective and prospective cohort studies. Three hundred sixty-five unique patients aged 6 years and older at baseline harboring disease-causing variants in the ABCA4 gene and with specified ocular lesions were enrolled from 9 centers in the United States and Europe. In the retrospective study, patients contributed medical record data from at least 2 and up to 4 visits for at least 1 examination modality: fundus autofluorescence (FAF), spectral-domain (SD) optical coherence tomography (SD OCT), and/or microperimetry (MP). The total observational period was at least 2 years and up to 5 years between single visits. Demographic and visual acuity (VA) data also were obtained. In the prospective study, eligible patients were examined at baseline using a standard protocol, with 6-month follow-up visits planned for a 2-year period for serial Early Treatment Diabetic Retinopathy Study (ETDRS) best-corrected VA, SD OCT, FAF, and MP. Design and rationale of a multicenter study to determine the progression of STGD1 in 2 large retrospective and prospective international cohorts. Detailed baseline characteristics of both cohorts are presented, including demographics, and structural and functional retinal metrics. Into the retrospective study, 251 patients (458 eyes) were enrolled; mean follow-up ± standard deviation was 3.9±1.6 years. At baseline, 36% had no or mild VA loss, and 47% of the study eyes had areas of definitely decreased autofluorescence (DDAF) with an average lesion area of 2.5±2.9 mm(2) (range, 0.02-16.03 mm(2)). Two hundred fifty-nine patients (489 eyes) were enrolled in the prospective study. At baseline, 20% had no or mild VA loss, and 64% had areas of DDAF with an average lesion area of 4.0±4.4 mm(2) (range, 0.03-24.24 mm(2)). The mean retinal sensitivity with MP was 10.8±5.0 dB. The ProgStar cohorts have baseline characteristics that encompass a wide range of disease severity and are expected to provide valuable data on progression based on serial quantitative measurements derived from multiple methods, which will be critical to the design of planned clinical trials. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  2. SU-G-BRA-16: Target Dose Comparison for Dynamic MLC Tracking and Mid- Ventilation Planning in Lung Radiotherapy Subject to Intrafractional Baseline Drifts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menten, MJ; Fast, MF; Nill, S

    Purpose: Lung tumor motion during radiotherapy can be accounted for by expanded treatment margins, for example using a mid-ventilation planning approach, or by localizing the tumor in real-time and adapting the treatment beam with multileaf collimator (MLC) tracking. This study evaluates the effect of intrafractional changes in the average tumor position (baseline drifts) on these two treatment techniques. Methods: Lung stereotactic treatment plans (9-beam IMRT, 54Gy/3 fractions, mean treatment time: 9.63min) were generated for three patients: either for delivery with MLC tracking (isotropic GTV-to-PTV margin: 2.6mm) or planned with a mid-ventilation approach and delivered without online motion compensation (GTV-to-PTV margin:more » 4.4-6.3mm). Delivery to a breathing patient was simulated using DynaTrack, our in-house tracking and delivery software. Baseline drifts in cranial and posterior direction were simulated at a rate of 0.5, 1.0 or 1.5mm/min. For dose reconstruction, the corresponding 4DCT phase was selected for each time point of the delivery. Baseline drifts were accounted for by rigidly shifting the CT to ensure correct relative beam-to-target positioning. Afterwards, the doses delivered to each 4DCT phase were accumulated deformably on the mid-ventilation phase using research RayStation v4.6 and dose coverage of the GTV was evaluated. Results: When using the mid-ventilation planning approach, dose coverage of the tumor deteriorated substantially in the presence of baseline drifts. The reduction in D98% coverage of the GTV in a single fraction ranged from 0.4-1.2, 0.6-3.3 and 4.5-6.2Gy, respectively, for the different drift rates. With MLC tracking the GTV D98% coverage remained unchanged (+/− 0.1Gy) regardless of drift. Conclusion: Intrafractional baseline drifts reduce the tumor dose in treatments based on mid-ventilation planning. In rare, large target baseline drifts tumor dose coverage may drop below the prescription, potentially affecting clinical outcome in hypofractionated treatment protocols. Dynamic MLC tracking preserves tumor dose coverage even in the presence of extreme baseline drifts. We acknowledge financial and technical support of the MLC tracking research from Elekta AB. Research at ICR is supported by CRUK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR. MFF is supported by CRUK under Programme C33589/A19908.« less

  3. Comparing bias correction methods in downscaling meteorological variables for a hydrologic impact study in an arid area in China

    NASA Astrophysics Data System (ADS)

    Fang, G. H.; Yang, J.; Chen, Y. N.; Zammit, C.

    2015-06-01

    Water resources are essential to the ecosystem and social economy in the desert and oasis of the arid Tarim River basin, northwestern China, and expected to be vulnerable to climate change. It has been demonstrated that regional climate models (RCMs) provide more reliable results for a regional impact study of climate change (e.g., on water resources) than general circulation models (GCMs). However, due to their considerable bias it is still necessary to apply bias correction before they are used for water resources research. In this paper, after a sensitivity analysis on input meteorological variables based on the Sobol' method, we compared five precipitation correction methods and three temperature correction methods in downscaling RCM simulations applied over the Kaidu River basin, one of the headwaters of the Tarim River basin. Precipitation correction methods applied include linear scaling (LS), local intensity scaling (LOCI), power transformation (PT), distribution mapping (DM) and quantile mapping (QM), while temperature correction methods are LS, variance scaling (VARI) and DM. The corrected precipitation and temperature were compared to the observed meteorological data, prior to being used as meteorological inputs of a distributed hydrologic model to study their impacts on streamflow. The results show (1) streamflows are sensitive to precipitation, temperature and solar radiation but not to relative humidity and wind speed; (2) raw RCM simulations are heavily biased from observed meteorological data, and its use for streamflow simulations results in large biases from observed streamflow, and all bias correction methods effectively improved these simulations; (3) for precipitation, PT and QM methods performed equally best in correcting the frequency-based indices (e.g., standard deviation, percentile values) while the LOCI method performed best in terms of the time-series-based indices (e.g., Nash-Sutcliffe coefficient, R2); (4) for temperature, all correction methods performed equally well in correcting raw temperature; and (5) for simulated streamflow, precipitation correction methods have more significant influence than temperature correction methods and the performances of streamflow simulations are consistent with those of corrected precipitation; i.e., the PT and QM methods performed equally best in correcting flow duration curve and peak flow while the LOCI method performed best in terms of the time-series-based indices. The case study is for an arid area in China based on a specific RCM and hydrologic model, but the methodology and some results can be applied to other areas and models.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xi; Mou, Xuanqin; Nishikawa, Robert M.

    Purpose: Small calcifications are often the earliest and the main indicator of breast cancer. Dual-energy digital mammography (DEDM) has been considered as a promising technique to improve the detectability of calcifications since it can be used to suppress the contrast between adipose and glandular tissues of the breast. X-ray scatter leads to erroneous calculations of the DEDM image. Although the pinhole-array interpolation method can estimate scattered radiations, it requires extra exposures to measure the scatter and apply the correction. The purpose of this work is to design an algorithmic method for scatter correction in DEDM without extra exposures.Methods: In thismore » paper, a scatter correction method for DEDM was developed based on the knowledge that scattered radiation has small spatial variation and that the majority of pixels in a mammogram are noncalcification pixels. The scatter fraction was estimated in the DEDM calculation and the measured scatter fraction was used to remove scatter from the image. The scatter correction method was implemented on a commercial full-field digital mammography system with breast tissue equivalent phantom and calcification phantom. The authors also implemented the pinhole-array interpolation scatter correction method on the system. Phantom results for both methods are presented and discussed. The authors compared the background DE calcification signals and the contrast-to-noise ratio (CNR) of calcifications in the three DE calcification images: image without scatter correction, image with scatter correction using pinhole-array interpolation method, and image with scatter correction using the authors' algorithmic method.Results: The authors' results show that the resultant background DE calcification signal can be reduced. The root-mean-square of background DE calcification signal of 1962 μm with scatter-uncorrected data was reduced to 194 μm after scatter correction using the authors' algorithmic method. The range of background DE calcification signals using scatter-uncorrected data was reduced by 58% with scatter-corrected data by algorithmic method. With the scatter-correction algorithm and denoising, the minimum visible calcification size can be reduced from 380 to 280 μm.Conclusions: When applying the proposed algorithmic scatter correction to images, the resultant background DE calcification signals can be reduced and the CNR of calcifications can be improved. This method has similar or even better performance than pinhole-array interpolation method in scatter correction for DEDM; moreover, this method is convenient and requires no extra exposure to the patient. Although the proposed scatter correction method is effective, it is validated by a 5-cm-thick phantom with calcifications and homogeneous background. The method should be tested on structured backgrounds to more accurately gauge effectiveness.« less

  5. Wheelchair pushrim kinetics measurement: A method to cancel inaccuracies due to pushrim weight and wheel camber.

    PubMed

    Chénier, Félix; Aissaoui, Rachid; Gauthier, Cindy; Gagnon, Dany H

    2017-02-01

    The commercially available SmartWheel TM is largely used in research and increasingly used in clinical practice to measure the forces and moments applied on the wheelchair pushrims by the user. However, in some situations (i.e. cambered wheels or increased pushrim weight), the recorded kinetics may include dynamic offsets that affect the accuracy of the measurements. In this work, an automatic method to identify and cancel these offsets is proposed and tested. First, the method was tested on an experimental bench with different cambers and pushrim weights. Then, the method was generalized to wheelchair propulsion. Nine experienced wheelchair users propelled their own wheelchairs instrumented with two SmartWheels with anti-slip pushrim covers. The dynamic offsets were correctly identified using the propulsion acquisition, without needing a separate baseline acquisition. A kinetic analysis was performed with and without dynamic offset cancellation using the proposed method. The most altered kinetic variables during propulsion were the vertical and total forces, with errors of up to 9N (p<0.001, large effect size of 5). This method is simple to implement, fully automatic and requires no further acquisitions. Therefore, we advise to use it systematically to enhance the accuracy of existing and future kinetic measurements. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Eye-motion-corrected optical coherence tomography angiography using Lissajous scanning.

    PubMed

    Chen, Yiwei; Hong, Young-Joo; Makita, Shuichi; Yasuno, Yoshiaki

    2018-03-01

    To correct eye motion artifacts in en face optical coherence tomography angiography (OCT-A) images, a Lissajous scanning method with subsequent software-based motion correction is proposed. The standard Lissajous scanning pattern is modified to be compatible with OCT-A and a corresponding motion correction algorithm is designed. The effectiveness of our method was demonstrated by comparing en face OCT-A images with and without motion correction. The method was further validated by comparing motion-corrected images with scanning laser ophthalmoscopy images, and the repeatability of the method was evaluated using a checkerboard image. A motion-corrected en face OCT-A image from a blinking case is presented to demonstrate the ability of the method to deal with eye blinking. Results show that the method can produce accurate motion-free en face OCT-A images of the posterior segment of the eye in vivo .

  7. White Matter Integrity and Treatment-Based Change in Speech Performance in Minimally Verbal Children with Autism Spectrum Disorder.

    PubMed

    Chenausky, Karen; Kernbach, Julius; Norton, Andrea; Schlaug, Gottfried

    2017-01-01

    We investigated the relationship between imaging variables for two language/speech-motor tracts and speech fluency variables in 10 minimally verbal (MV) children with autism. Specifically, we tested whether measures of white matter integrity-fractional anisotropy (FA) of the arcuate fasciculus (AF) and frontal aslant tract (FAT)-were related to change in percent syllable-initial consonants correct, percent items responded to, and percent syllable insertion errors (from best baseline to post 25 treatment sessions). Twenty-three MV children with autism spectrum disorder (ASD) received Auditory-Motor Mapping Training (AMMT), an intonation-based treatment to improve fluency in spoken output, and we report on seven who received a matched control treatment. Ten of the AMMT participants were able to undergo a magnetic resonance imaging study at baseline; their performance on baseline speech production measures is compared to that of the other two groups. No baseline differences were found between groups. A canonical correlation analysis (CCA) relating FA values for left- and right-hemisphere AF and FAT to speech production measures showed that FA of the left AF and right FAT were the largest contributors to the synthetic independent imaging-related variable. Change in percent syllable-initial consonants correct and percent syllable-insertion errors were the largest contributors to the synthetic dependent fluency-related variable. Regression analyses showed that FA values in left AF significantly predicted change in percent syllable-initial consonants correct, no FA variables significantly predicted change in percent items responded to, and FA of right FAT significantly predicted change in percent syllable-insertion errors. Results are consistent with previously identified roles for the AF in mediating bidirectional mapping between articulation and acoustics, and the FAT in its relationship to speech initiation and fluency. They further suggest a division of labor between the hemispheres, implicating the left hemisphere in accuracy of speech production and the right hemisphere in fluency in this population. Changes in response rate are interpreted as stemming from factors other than the integrity of these two fiber tracts. This study is the first to document the existence of a subgroup of MV children who experience increases in syllable- insertion errors as their speech develops in response to therapy.

  8. Deformation Time-Series of the Lost-Hills Oil Field using a Multi-Baseline Interferometric SAR Inversion Algorithm with Finite Difference Smoothing Constraints

    NASA Astrophysics Data System (ADS)

    Werner, C. L.; Wegmüller, U.; Strozzi, T.

    2012-12-01

    The Lost-Hills oil field located in Kern County,California ranks sixth in total remaining reserves in California. Hundreds of densely packed wells characterize the field with one well every 5000 to 20000 square meters. Subsidence due to oil extraction can be grater than 10 cm/year and is highly variable both in space and time. The RADARSAT-1 SAR satellite collected data over this area with a 24-day repeat during a 2 year period spanning 2002-2004. Relatively high interferometric correlation makes this an excellent region for development and test of deformation time-series inversion algorithms. Errors in deformation time series derived from a stack of differential interferograms are primarily due to errors in the digital terrain model, interferometric baselines, variability in tropospheric delay, thermal noise and phase unwrapping errors. Particularly challenging is separation of non-linear deformation from variations in troposphere delay and phase unwrapping errors. In our algorithm a subset of interferometric pairs is selected from a set of N radar acquisitions based on criteria of connectivity, time interval, and perpendicular baseline. When possible, the subset consists of temporally connected interferograms, otherwise the different groups of interferograms are selected to overlap in time. The maximum time interval is constrained to be less than a threshold value to minimize phase gradients due to deformation as well as minimize temporal decorrelation. Large baselines are also avoided to minimize the consequence of DEM errors on the interferometric phase. Based on an extension of the SVD based inversion described by Lee et al. ( USGS Professional Paper 1769), Schmidt and Burgmann (JGR, 2003), and the earlier work of Berardino (TGRS, 2002), our algorithm combines estimation of the DEM height error with a set of finite difference smoothing constraints. A set of linear equations are formulated for each spatial point that are functions of the deformation velocities during the time intervals spanned by the interferogram and a DEM height correction. The sensitivity of the phase to the height correction depends on the length of the perpendicular baseline of each interferogram. This design matrix is augmented with a set of additional weighted constraints on the acceleration that penalize rapid velocity variations. The weighting factor γ can be varied from 0 (no smoothing) to a large values (> 10) that yield an essentially linear time-series solution. The factor can be tuned to take into account a priori knowledge of the deformation non-linearity. The difference between the time-series solution and the unconstrained time-series can be interpreted as due to a combination of tropospheric path delay and baseline error. Spatial smoothing of the residual phase leads to an improved atmospheric model that can be fed back into the model and iterated. Our analysis shows non-linear deformation related to changes in the oil extraction as well as local height corrections improving on the low resolution 3 arc-sec SRTM DEM.

  9. Conservative DEC Discretization of Incompressible Navier-Stokes Equations on Arbitrary Surface Simplicial Meshes

    NASA Astrophysics Data System (ADS)

    Mohamed, Mamdouh; Hirani, Anil; Samtaney, Ravi

    2017-11-01

    A conservative discretization of incompressible Navier-Stokes equations over surfaces is developed using discrete exterior calculus (DEC). The mimetic character of many of the DEC operators provides exact conservation of both mass and vorticity, in addition to superior kinetic energy conservation. The employment of signed diagonal Hodge star operators, while using the circumcentric dual defined on arbitrary meshes, is shown to produce correct solutions even when many non-Delaunay triangles pairs exist. This allows the DEC discretization to admit arbitrary surface simplicial meshes, in contrast to the previously held notion that DEC was limited only to Delaunay meshes. The discretization scheme is presented along with several numerical test cases demonstrating its numerical convergence and conservation properties. Recent developments regarding the extension to conservative higher order methods are also presented. KAUST Baseline Research Funds of R. Samtaney.

  10. Investigation of Low-Reynolds-Number Rocket Nozzle Design Using PNS-Based Optimization Procedure

    NASA Technical Reports Server (NTRS)

    Hussaini, M. Moin; Korte, John J.

    1996-01-01

    An optimization approach to rocket nozzle design, based on computational fluid dynamics (CFD) methodology, is investigated for low-Reynolds-number cases. This study is undertaken to determine the benefits of this approach over those of classical design processes such as Rao's method. A CFD-based optimization procedure, using the parabolized Navier-Stokes (PNS) equations, is used to design conical and contoured axisymmetric nozzles. The advantage of this procedure is that it accounts for viscosity during the design process; other processes make an approximated boundary-layer correction after an inviscid design is created. Results showed significant improvement in the nozzle thrust coefficient over that of the baseline case; however, the unusual nozzle design necessitates further investigation of the accuracy of the PNS equations for modeling expanding flows with thick laminar boundary layers.

  11. Preferred color correction for digital LCD TVs

    NASA Astrophysics Data System (ADS)

    Kim, Kyoung Tae; Kim, Choon-Woo; Ahn, Ji-Young; Kang, Dong-Woo; Shin, Hyun-Ho

    2009-01-01

    Instead of colorimetirc color reproduction, preferred color correction is applied for digital TVs to improve subjective image quality. First step of the preferred color correction is to survey the preferred color coordinates of memory colors. This can be achieved by the off-line human visual tests. Next step is to extract pixels of memory colors representing skin, grass and sky. For the detected pixels, colors are shifted towards the desired coordinates identified in advance. This correction process may result in undesirable contours on the boundaries between the corrected and un-corrected areas. For digital TV applications, the process of extraction and correction should be applied in every frame of the moving images. This paper presents a preferred color correction method in LCH color space. Values of chroma and hue are corrected independently. Undesirable contours on the boundaries of correction are minimized. The proposed method change the coordinates of memory color pixels towards the target color coordinates. Amount of correction is determined based on the averaged coordinate of the extracted pixels. The proposed method maintains the relative color difference within memory color areas. Performance of the proposed method is evaluated using the paired comparison. Results of experiments indicate that the proposed method can reproduce perceptually pleasing images to viewers.

  12. Trainable structure-activity relationship model for virtual screening of CYP3A4 inhibition.

    PubMed

    Didziapetris, Remigijus; Dapkunas, Justas; Sazonovas, Andrius; Japertas, Pranas

    2010-11-01

    A new structure-activity relationship model predicting the probability for a compound to inhibit human cytochrome P450 3A4 has been developed using data for >800 compounds from various literature sources and tested on PubChem screening data. Novel GALAS (Global, Adjusted Locally According to Similarity) modeling methodology has been used, which is a combination of baseline global QSAR model and local similarity based corrections. GALAS modeling method allows forecasting the reliability of prediction thus defining the model applicability domain. For compounds within this domain the statistical results of the final model approach the data consistency between experimental data from literature and PubChem datasets with the overall accuracy of 89%. However, the original model is applicable only for less than a half of PubChem database. Since the similarity correction procedure of GALAS modeling method allows straightforward model training, the possibility to expand the applicability domain has been investigated. Experimental data from PubChem dataset served as an example of in-house high-throughput screening data. The model successfully adapted itself to both data classified using the same and different IC₅₀ threshold compared with the training set. In addition, adjustment of the CYP3A4 inhibition model to compounds with a novel chemical scaffold has been demonstrated. The reported GALAS model is proposed as a useful tool for virtual screening of compounds for possible drug-drug interactions even prior to the actual synthesis.

  13. Length bias correction in one-day cross-sectional assessments - The nutritionDay study.

    PubMed

    Frantal, Sophie; Pernicka, Elisabeth; Hiesmayr, Michael; Schindler, Karin; Bauer, Peter

    2016-04-01

    A major problem occurring in cross-sectional studies is sampling bias. Length of hospital stay (LOS) differs strongly between patients and causes a length bias as patients with longer LOS are more likely to be included and are therefore overrepresented in this type of study. To adjust for the length bias higher weights are allocated to patients with shorter LOS. We determined the effect of length-bias adjustment in two independent populations. Length-bias correction is applied to the data of the nutritionDay project, a one-day multinational cross-sectional audit capturing data on disease and nutrition of patients admitted to hospital wards with right-censoring after 30 days follow-up. We applied the weighting method for estimating the distribution function of patient baseline variables based on the method of non-parametric maximum likelihood. Results are validated using data from all patients admitted to the General Hospital of Vienna between 2005 and 2009, where the distribution of LOS can be assumed to be known. Additionally, a simplified calculation scheme for estimating the adjusted distribution function of LOS is demonstrated on a small patient example. The crude median (lower quartile; upper quartile) LOS in the cross-sectional sample was 14 (8; 24) and decreased to 7 (4; 12) when adjusted. Hence, adjustment for length bias in cross-sectional studies is essential to get appropriate estimates. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  14. A pilot educational intervention for headache and concussion: The headache and arts program.

    PubMed

    Minen, Mia T; Boubour, Alexandra

    2018-05-15

    Using a science, technology, engineering, arts, and mathematics (STEAM) curriculum, we developed, piloted, and tested the Headache and Arts Program. This program seeks to increase knowledge and awareness of migraine and concussion among high school students through a visual arts-based curriculum. We developed a 2-week Headache and Arts Program with lesson plans and art assignments for high school visual arts classes and an age-appropriate assessment to assess students' knowledge of migraine and concussion. We assessed students' knowledge through (1) the creation of artwork that depicted the experience of a migraine or concussion, (2) the conception and implementation of methods to transfer knowledge gained through the program, and (3) preassessment and postassessment results. The assessment was distributed to all students prior to the Headache and Arts Program. In a smaller sample, we distributed the assessment 3 months after the program to assess longitudinal effects. Descriptive analyses and p values were calculated using SPSS V.24 and Microsoft Excel. Forty-eight students participated in the research program. Students created artwork that integrated STEAM knowledge learned through the program and applied creative methods to teach others about migraine and concussion. At baseline, students' total scores averaged 67.6% correct. Total scores for the longitudinal preassessment, immediate postassessment, and delayed 3-month postassessment averaged 69.4%, 72.8%, and 80.0% correct, respectively. The use of a visual arts-based curriculum may be effective for migraine and concussion education among high school students. © 2018 American Academy of Neurology.

  15. Comparison of demons deformable registration-based methods for texture analysis of serial thoracic CT scans

    NASA Astrophysics Data System (ADS)

    Cunliffe, Alexandra R.; Al-Hallaq, Hania A.; Fei, Xianhan M.; Tuohy, Rachel E.; Armato, Samuel G.

    2013-02-01

    To determine how 19 image texture features may be altered by three image registration methods, "normal" baseline and follow-up computed tomography (CT) scans from 27 patients were analyzed. Nineteen texture feature values were calculated in over 1,000 32x32-pixel regions of interest (ROIs) randomly placed in each baseline scan. All three methods used demons registration to map baseline scan ROIs to anatomically matched locations in the corresponding transformed follow-up scan. For the first method, the follow-up scan transformation was subsampled to achieve a voxel size identical to that of the baseline scan. For the second method, the follow-up scan was transformed through affine registration to achieve global alignment with the baseline scan. For the third method, the follow-up scan was directly deformed to the baseline scan using demons deformable registration. Feature values in matched ROIs were compared using Bland- Altman 95% limits of agreement. For each feature, the range spanned by the 95% limits was normalized to the mean feature value to obtain the normalized range of agreement, nRoA. Wilcoxon signed-rank tests were used to compare nRoA values across features for the three methods. Significance for individual tests was adjusted using the Bonferroni method. nRoA was significantly smaller for affine-registered scans than for the resampled scans (p=0.003), indicating lower feature value variability between baseline and follow-up scan ROIs using this method. For both of these methods, however, nRoA was significantly higher than when feature values were calculated directly on demons-deformed followup scans (p<0.001). Across features and methods, nRoA values remained below 26%.

  16. A Randomized Trial of Soft Multifocal Contact Lenses for Myopia Control: Baseline Data and Methods.

    PubMed

    Walline, Jeffrey J; Gaume Giannoni, Amber; Sinnott, Loraine T; Chandler, Moriah A; Huang, Juan; Mutti, Donald O; Jones-Jordan, Lisa A; Berntsen, David A

    2017-09-01

    The Bifocal Lenses In Nearsighted Kids (BLINK) study is the first soft multifocal contact lens myopia control study to compare add powers and measure peripheral refractive error in the vertical meridian, so it will provide important information about the potential mechanism of myopia control. The BLINK study is a National Eye Institute-sponsored, double-masked, randomized clinical trial to investigate the effects of soft multifocal contact lenses on myopia progression. This article describes the subjects' baseline characteristics and study methods. Subjects were 7 to 11 years old, had -0.75 to -5.00 spherical component and less than 1.00 diopter (D) astigmatism, and had 20/25 or better logMAR distance visual acuity with manifest refraction in each eye and with +2.50-D add soft bifocal contact lenses on both eyes. Children were randomly assigned to wear Biofinity single-vision, Biofinity Multifocal "D" with a +1.50-D add power, or Biofinity Multifocal "D" with a +2.50-D add power contact lenses. We examined 443 subjects at the baseline visits, and 294 (66.4%) subjects were enrolled. Of the enrolled subjects, 177 (60.2%) were female, and 200 (68%) were white. The mean (± SD) age was 10.3 ± 1.2 years, and 117 (39.8%) of the eligible subjects were younger than 10 years. The mean spherical equivalent refractive error, measured by cycloplegic autorefraction was -2.39 ± 1.00 D. The best-corrected binocular logMAR visual acuity with glasses was +0.01 ± 0.06 (20/21) at distance and -0.03 ± 0.08 (20/18) at near. The BLINK study subjects are similar to patients who would routinely be eligible for myopia control in practice, so the results will provide clinical information about soft bifocal contact lens myopia control as well as information about the mechanism of the treatment effect, if one occurs.

  17. Goal-Directed Transthoracic Echocardiography During Advanced Cardiac Life Support: A Pilot Study Using Simulation to Assess Ability.

    PubMed

    Greenstein, Yonatan Y; Martin, Thomas J; Rolnitzky, Linda; Felner, Kevin; Kaufman, Brian

    2015-08-01

    Goal-directed echocardiography (GDE) is used to answer specific clinical questions that provide invaluable information to physicians managing a hemodynamically unstable patient. We studied perception and ability of house staff previously trained in GDE to accurately diagnose common causes of cardiac arrest during simulated advanced cardiac life support (ACLS); we compared their results with those of expert echocardiographers. Eleven pulmonary and critical care medicine fellows, 7 emergency medicine residents, and 5 cardiologists board certified in echocardiography were enrolled. Baseline ability to acquire 4 transthoracic echocardiography views was assessed, and participants were exposed to 6 simulated cardiac arrests and were asked to perform a GDE during ACLS. House staff performance was compared with the performance of 5 expert echocardiographers. Average baseline and scenario views by house staff were of good or excellent quality 89% and 83% of the time, respectively. Expert average baseline and scenario views were always of good or excellent quality. House staff and experts made the correct diagnosis in 68% and 77% of cases, respectively. On average, participants required 1.5 pulse checks to make the correct diagnosis. Of house staff, 94% perceived this study as an accurate assessment of ability. In an ACLS-compliant manner, house staff are capable of diagnosing management-altering pathologies the majority of the time, and they reach similar diagnostic conclusions in the same amount of time as expert echocardiographers in a simulated cardiac arrest scenario.

  18. 3D Tomographic SAR Imaging in Densely Vegetated Mountainous Rural Areas in China and Sweden

    NASA Astrophysics Data System (ADS)

    Feng, L.; Muller, J. P., , Prof

    2017-12-01

    3D SAR Tomography (TomoSAR) and 4D SAR Differential Tomography (Diff-TomoSAR) exploit multi-baseline SAR data stacks to create an important new innovation of SAR Interferometry, to unscramble complex scenes with multiple scatterers mapped into the same SAR cell. In addition to this 3-D shape reconstruction and deformation solution in complex urban/infrastructure areas, and recent cryospheric ice investigations, emerging tomographic remote sensing applications include forest applications, e.g. tree height and biomass estimation, sub-canopy topographic mapping, and even search, rescue and surveillance. However, these scenes are characterized by temporal decorrelation of scatterers, orbital, tropospheric and ionospheric phase distortion and an open issue regarding possible height blurring and accuracy losses for TomoSAR applications particularly in densely vegetated mountainous rural areas. Thus, it is important to develop solutions for temporal decorrelation, orbital, tropospheric and ionospheric phase distortion.We report here on 3D imaging (especially in vertical layers) over densely vegetated mountainous rural areas using 3-D SAR imaging (SAR tomography) derived from data stacks of X-band COSMO-SkyMed Spotlight and L band ALOS-1 PALSAR data stacks over Dujiangyan Dam, Sichuan, China and L and P band airborne SAR data (BioSAR 2008 - ESA) in the Krycklan river catchment, Northern Sweden. The new TanDEM-X 12m DEM is used to assist co - registration of all the data stacks over China first. Then, atmospheric correction is being assessed using weather model data such as ERA-I, MERRA, MERRA-2, WRF; linear phase-topography correction and MODIS spectrometer correction will be compared and ionospheric correction methods are discussed to remove tropospheric and ionospheric delay. Then the new TomoSAR method with the TanDEM-X 12m DEM is described to obtain the number of scatterers inside each pixel, the scattering amplitude and phase of each scatterer and finally extract tomograms (imaging), their 3D positions and motion parameters (deformation). A progress report will be shown on these different aspects.This work is partially supported by the CSC and UCL MAPS Dean prize through a PhD studentship at UCL-MSSL.

  19. Insar Unwrapping Error Correction Based on Quasi-Accurate Detection of Gross Errors (quad)

    NASA Astrophysics Data System (ADS)

    Kang, Y.; Zhao, C. Y.; Zhang, Q.; Yang, C. S.

    2018-04-01

    Unwrapping error is a common error in the InSAR processing, which will seriously degrade the accuracy of the monitoring results. Based on a gross error correction method, Quasi-accurate detection (QUAD), the method for unwrapping errors automatic correction is established in this paper. This method identifies and corrects the unwrapping errors by establishing a functional model between the true errors and interferograms. The basic principle and processing steps are presented. Then this method is compared with the L1-norm method with simulated data. Results show that both methods can effectively suppress the unwrapping error when the ratio of the unwrapping errors is low, and the two methods can complement each other when the ratio of the unwrapping errors is relatively high. At last the real SAR data is tested for the phase unwrapping error correction. Results show that this new method can correct the phase unwrapping errors successfully in the practical application.

  20. Systems Training for Emotional Predictability and Problem Solving (STEPPS) group treatment for offenders with borderline personality disorder.

    PubMed

    Black, Donald W; Blum, Nancee; McCormick, Brett; Allen, Jeff

    2013-02-01

    Systems Training for Emotional Predictability and Problem Solving (STEPPS) is a manual-based group treatment of persons with borderline personality disorder (BPD). We report results from a study of offenders supervised by the Iowa Department of Corrections. Seventy-seven offenders participated in STEPPS groups. The offenders experienced clinically significant improvement in BPD-related symptoms (d = 1.30), mood, and negative affectivity. Suicidal behaviors and disciplinary infractions were reduced. Baseline severity was inversely associated with improvement. The offenders indicated satisfaction with STEPPS. We conclude that STEPPS can be successfully integrated into the care of offenders with BPD in prison and community corrections settings.

  1. Training program for Japanese medical personnel to combat child maltreatment.

    PubMed

    Tanoue, Koji; Senda, Masayoshi; An, Byongmun; Tasaki, Midori; Taguchi, Megumi; Kobashi, Kosuke; Oana, Shinji; Mizoguchi, Fumitake; Shiraishi, Yuko; Yamada, Fujiko; Okuyama, Makiko; Ichikawa, Kotaro

    2017-07-01

    In 2014, we created a training program for personnel in medical institutions in Japan to combat child maltreatment. The aim of the present study was to document the effectiveness of this program. Participants completed a questionnaire before and after the training lecture. The questionnaire designed for the training program included demographic questions such years of practice and area of specialty (i.e. physician, nurse, social worker, public health nurse, technician, and others), as well as experience of suspected child maltreatment cases and training in dealing with such cases. The questionnaire included 15 statements designed to ascertain practical knowledge and attitudes relevant to addressing child maltreatment. Baseline score measured before the lecture was compared with that obtained after the lecture. A total of 760 participants completed the survey, including 227 physicians, 223 nurses, 38 technologists, 27 social workers, 11 public health nurses, and 174 with other occupations, and 60 participants who left their occupation as blank. There was a significant difference between the baseline score of participants with versus without experience in suspected child maltreatment or training to deal with child maltreatment (F = 16.3; P < 0.001). After the lecture, the average score rose above the baseline (11.18 vs 10.57). The rate of correct answers for nine questionnaire items increased significantly. Professionals from a range of fields need clinical skills and judgement to decide if a child's injuries are due to maltreatment. The combination of increased clinical experience along with a high-quality didactic lecture, appears to be the most effective method of raising awareness and enhancing skills. © 2017 Japan Pediatric Society.

  2. Contact lens assessment in youth: methods and baseline findings.

    PubMed

    Lam, Dawn Y; Kinoshita, Beth T; Jansen, Meredith E; Mitchell, G Lynn; Chalmers, Robin L; McMahon, Timothy T; Richdale, Kathryn; Sorbara, Luigina; Wagner, Heidi

    2011-06-01

    To describe the Contact Lens Assessment in Youth (CLAY) Study design and report baseline data for a multicenter, retrospective, observational chart review of children, teenagers, and young adult soft contact lens (SCL) wearers. Clinical charts of SCL wearers aged 8 to 33 years were reviewed at six colleges of optometry. Data were captured retrospectively for eye care visits from January 2006 through September 2009. Patient demographics, SCL parameters, wearing schedules, care systems, and biomicroscopy findings and complications that interrupted SCL wear were entered into an online database. Charts from 3549 patients (14,276 visits) were reviewed; 78.8% were current SCL wearers and 21.2% were new fits. Age distribution was 8 to <13 years (n = 260, 7.3%), 13 to <18 years (n = 879, 24.8%), 18 to <26 years (n = 1,274, 36.0%), and 26 to <34 years (n = 1,136, 32.0%). The sample was 63.2% females and 37.7% college students. At baseline, 85.2% wore spherical SCLs, 13.5% torics, and 0.1% multifocals. Silicone hydrogel lenses were worn by 39.3% of the cohort. Daily wear was reported by 82.1%, whereas 17.9% reported any or occasional overnight wear. Multipurpose care systems were used by 78.1%, whereas another 9.9% indicated hydrogen peroxide solutions use. This data represent the SCL prescribing and wearing patterns for children, teenager, and young adult SCL wearers who presented for eye care in North American academic clinics. This will provide insight into SCL utilization, change in SCL refractive correction, and risk factors for SCL-related complications by age group.

  3. Association of objectively measured arm inclination with shoulder pain: A 6-month follow-up prospective study of construction and health care workers

    PubMed Central

    Koch, Markus; Lunde, Lars-Kristian; Veiersted, Kaj Bo; Knardahl, Stein

    2017-01-01

    Objectives The aim was to determine the association of occupational arm inclination with shoulder pain in construction and health care workers. Methods Arm inclination relative to the vertical was measured with an accelerometer placed on the dominant upper arm for up to four full days at baseline in 62 construction workers and 63 health care workers. The pain intensity in the shoulder and mechanical and psychosocial work factors were measured by self-reports at baseline and prospectively after 6 months. The associations between exposures and shoulder pain were analyzed with multilevel mixed-effects linear regressions. Results For the total study population working with the dominant arm at inclinations > 30° and >120° was associated with lower levels of shoulder pain both cross-sectionally and after 6 months. Associations were attenuated when adjusting for individual and social factors, psychological state, and exposure during leisure time, especially for the high inclination levels. Analyses, only including subjects with no pain at baseline revealed no significant associations. While stratified analysis showed negative associations in the construction worker group, there were no significant association in health care workers. Compared to the number of hypotheses tested, the number of significant findings was low. Adjustment by Bonferroni-correction made almost all findings insignificant. Conclusions All analyses reflected a negative association between arm inclination and shoulder pain, but few analyses showed these associations to be statistically significant. If there is a relationship between arm inclination and shoulder pain, these findings could indicate that pain-avoidance may modify how workers perform their tasks. PMID:29176761

  4. Functional changes after treatment of optic pathway paediatric low-grade gliomas

    PubMed Central

    Magli, A; Forte, R; Cinalli, G; Esposito, F; Parisi, S; Capasso, M; Papparella, A

    2013-01-01

    Objective To evaluate the functional changes after treatment of paediatric optic pathway gliomas (OPGs). Methods All patients with monofocal OPG seen from January 2004 to January 2011 were included. Best corrected visual acuity (BCVA, LogMAR), contrast sensitivity (Hiding-Heidi low-contrast ‘face' test (HH) and Pelli−Robson (PR) contrast sensitivity test), and the Color Test (Ishihara plate) were obtained. Results Twenty-one patients (10 boys and 11 girls with a mean age of 5.5±4.4 years at diagnosis) were included in the study. Neurofibromatosis was present in four cases. Eighteen patients (85.7%) were treated with initial surgery and three patients (14.3%) with initial chemotherapy. BCVA was 0.67±0.8 LogMAR at baseline and 0.62±0.9 LogMAR at last visit (P=0.41). The Color test was not significantly changed at last visit (P=0.62). Contrast sensitivity with the HH test was 9.1±11.1% at baseline and 3.8±6.4% at last visit (P=0.03). Contrast sensitivity with PR chart was 1.33±0.9log at baseline and 1.05±0.7 log at last visit (P=0.005). A reduction in contrast sensitivity at both tests was significantly greater in patients who relapsed than in patients who did not relapse (P=0.001). Conclusion After the treatment of paediatric optic pathway low-grade gliomas, a reduction in contrast sensitivity during follow-up was observed and may be correlated with tumour relapses. PMID:23970029

  5. The Impact of Reading to Engage Children with Autism in Language and Learning (RECALL)

    ERIC Educational Resources Information Center

    Whalon, Kelly; Martinez, Jose R.; Shannon, Darbianne; Butcher, Colleen; Hanline, Mary Frances

    2015-01-01

    A multiple baseline across participants design was used to investigate the impact of RECALL (Reading to Engage Children With Autism in Language and Learning) on the correct, unprompted responding and initiations of young children with autism spectrum disorder (ASD). RECALL is an adapted shared reading intervention based on dialogic reading. RECALL…

  6. Effects of White Noise on Off-Task Behavior and Academic Responding for Children with ADHD

    ERIC Educational Resources Information Center

    Cook, Andrew; Bradley-Johnson, Sharon; Johnson, C. Merle

    2014-01-01

    We evaluated the effects of white noise played through headphones on off-task behavior, percentage of items completed, and percentage of items completed correctly for 3 students with attention deficit hyperactivity disorder (ADHD). Headphones plus white noise were associated with decreases in off-task behavior relative to baseline and…

  7. Baseline Measurement of Running Away among Youth in Foster Care

    ERIC Educational Resources Information Center

    Witherup, Luanne R.; Vollmer, Timothy R.; Van Camp, Carole M.; Goh, Han-Leong; Borrero, John C.; Mayfield, Kristin

    2008-01-01

    The current study evaluated the use of various behavioral measures of running away with regard to (a) the differential utility of interval- versus event-based measures, (b) the differential utility of rate versus duration measures, (c) the utility of correcting for occurrence opportunity, and (d) the influence of unit of analysis (i.e.,…

  8. Basic research for the geodynamics program

    NASA Technical Reports Server (NTRS)

    Mueller, I. I.

    1982-01-01

    Work performed and data obtained in geodynamic research is reported. The purpose was to obtain utilization of: (1) laser and very long baseline interferometry (VLBI); (2) range difference observation in geodynamics; (3) development of models for ice sheet and crustal deformations. The effects of adopting new precession, nutation and equinox corrections on the terrestrial reference frame are investigated.

  9. Validation of a T1 and T2* leakage correction method based on multi-echo DSC-MRI using MION as a reference standard

    PubMed Central

    Stokes, Ashley M.; Semmineh, Natenael; Quarles, C. Chad

    2015-01-01

    Purpose A combined biophysical- and pharmacokinetic-based method is proposed to separate, quantify, and correct for both T1 and T2* leakage effects using dual-echo DSC acquisitions to provide more accurate hemodynamic measures, as validated by a reference intravascular contrast agent (CA). Methods Dual-echo DSC-MRI data were acquired in two rodent glioma models. The T1 leakage effects were removed and also quantified in order to subsequently correct for the remaining T2* leakage effects. Pharmacokinetic, biophysical, and combined biophysical and pharmacokinetic models were used to obtain corrected cerebral blood volume (CBV) and cerebral blood flow (CBF), and these were compared with CBV and CBF from an intravascular CA. Results T1-corrected CBV was significantly overestimated compared to MION CBV, while T1+T2*-correction yielded CBV values closer to the reference values. The pharmacokinetic and simplified biophysical methods showed similar results and underestimated CBV in tumors exhibiting strong T2* leakage effects. The combined method was effective for correcting T1 and T2* leakage effects across tumor types. Conclusions Correcting for both T1 and T2* leakage effects yielded more accurate measures of CBV. The combined correction method yields more reliable CBV measures than either correction method alone, but for certain brain tumor types (e.g., gliomas) the simplified biophysical method may provide a robust and computationally efficient alternative. PMID:26362714

  10. An improved bias correction method of daily rainfall data using a sliding window technique for climate change impact assessment

    NASA Astrophysics Data System (ADS)

    Smitha, P. S.; Narasimhan, B.; Sudheer, K. P.; Annamalai, H.

    2018-01-01

    Regional climate models (RCMs) are used to downscale the coarse resolution General Circulation Model (GCM) outputs to a finer resolution for hydrological impact studies. However, RCM outputs often deviate from the observed climatological data, and therefore need bias correction before they are used for hydrological simulations. While there are a number of methods for bias correction, most of them use monthly statistics to derive correction factors, which may cause errors in the rainfall magnitude when applied on a daily scale. This study proposes a sliding window based daily correction factor derivations that help build reliable daily rainfall data from climate models. The procedure is applied to five existing bias correction methods, and is tested on six watersheds in different climatic zones of India for assessing the effectiveness of the corrected rainfall and the consequent hydrological simulations. The bias correction was performed on rainfall data downscaled using Conformal Cubic Atmospheric Model (CCAM) to 0.5° × 0.5° from two different CMIP5 models (CNRM-CM5.0, GFDL-CM3.0). The India Meteorological Department (IMD) gridded (0.25° × 0.25°) observed rainfall data was considered to test the effectiveness of the proposed bias correction method. The quantile-quantile (Q-Q) plots and Nash Sutcliffe efficiency (NSE) were employed for evaluation of different methods of bias correction. The analysis suggested that the proposed method effectively corrects the daily bias in rainfall as compared to using monthly factors. The methods such as local intensity scaling, modified power transformation and distribution mapping, which adjusted the wet day frequencies, performed superior compared to the other methods, which did not consider adjustment of wet day frequencies. The distribution mapping method with daily correction factors was able to replicate the daily rainfall pattern of observed data with NSE value above 0.81 over most parts of India. Hydrological simulations forced using the bias corrected rainfall (distribution mapping and modified power transformation methods that used the proposed daily correction factors) was similar to those simulated by the IMD rainfall. The results demonstrate that the methods and the time scales used for bias correction of RCM rainfall data have a larger impact on the accuracy of the daily rainfall and consequently the simulated streamflow. The analysis suggests that the distribution mapping with daily correction factors can be preferred for adjusting RCM rainfall data irrespective of seasons or climate zones for realistic simulation of streamflow.

  11. Evaluation and parameterization of ATCOR3 topographic correction method for forest cover mapping in mountain areas

    NASA Astrophysics Data System (ADS)

    Balthazar, Vincent; Vanacker, Veerle; Lambin, Eric F.

    2012-08-01

    A topographic correction of optical remote sensing data is necessary to improve the quality of quantitative forest cover change analyses in mountainous terrain. The implementation of semi-empirical correction methods requires the calibration of model parameters that are empirically defined. This study develops a method to improve the performance of topographic corrections for forest cover change detection in mountainous terrain through an iterative tuning method of model parameters based on a systematic evaluation of the performance of the correction. The latter was based on: (i) the general matching of reflectances between sunlit and shaded slopes and (ii) the occurrence of abnormal reflectance values, qualified as statistical outliers, in very low illuminated areas. The method was tested on Landsat ETM+ data for rough (Ecuadorian Andes) and very rough mountainous terrain (Bhutan Himalayas). Compared to a reference level (no topographic correction), the ATCOR3 semi-empirical correction method resulted in a considerable reduction of dissimilarities between reflectance values of forested sites in different topographic orientations. Our results indicate that optimal parameter combinations are depending on the site, sun elevation and azimuth and spectral conditions. We demonstrate that the results of relatively simple topographic correction methods can be greatly improved through a feedback loop between parameter tuning and evaluation of the performance of the correction model.

  12. [Evaluation of four dark object atmospheric correction methods based on ZY-3 CCD data].

    PubMed

    Guo, Hong; Gu, Xing-fa; Xie, Yong; Yu, Tao; Gao, Hai-liang; Wei, Xiang-qin; Liu, Qi-yue

    2014-08-01

    The present paper performed the evaluation of four dark-object subtraction(DOS) atmospheric correction methods based on 2012 Inner Mongolia experimental data The authors analyzed the impacts of key parameters of four DOS methods when they were applied to ZY-3 CCD data The results showed that (1) All four DOS methods have significant atmospheric correction effect at band 1, 2 and 3. But as for band 4, the atmospheric correction effect of DOS4 is the best while DOS2 is the worst; both DOS1 and DOS3 has no obvious atmospheric correction effect. (2) The relative error (RE) of DOS1 atmospheric correction method is larger than 10% at four bands; The atmospheric correction effect of DOS2 works the best at band 1(AE (absolute error)=0.0019 and RE=4.32%) and the worst error appears at band 4(AE=0.0464 and RE=19.12%); The RE of DOS3 is about 10% for all bands. (3) The AE of atmospheric correction results for DOS4 method is less than 0. 02 and the RE is less than 10% for all bands. Therefore, the DOS4 method provides the best accuracy of atmospheric correction results for ZY-3 image.

  13. Endpoint titration and immunotherapy.

    PubMed

    King, H C

    1985-11-01

    Inhalant allergy, or "atopy" as it is now termed, is the best understood form of allergy today. In some circles, it is the only recognized form of allergy. While an overall picture of its effects on the body and a reasonable approach to its treatment now exist, many problems remain to be solved and much improvement in its treatment will probably occur within the next several years. Many new approaches to treatment of aeroallergens are now available; however, all are compared with the skin test, which is and has been the baseline for testing and treatment. Endpoint titration provides a quantitative means for undertaking treatment of aeroallergen sensitivity. In no other way does it differ from the forms of skin testing that have been widely used for generations. The practitioners of endpoint titration feel that this difference is highly significant in simplifying, validating, and shortening the necessary period of therapy. While the concept of endpoint titration is not difficult, it is by definition a quantitative form of testing and requires a degree of expertise in performing it correctly. While a good understanding of the method may be gained from the literature, adequate hands-on experience should be obtained by any physician prior to instituting the technique as a treatment modality. Once mastered, it becomes a reliable baseline for all forms of inhalant allergy care.

  14. Impact of Trichiasis Surgery on Physical Functioning in Ethiopian Patients: STAR Trial

    PubMed Central

    Wolle, Meraf A.; Cassard, Sandra D.; Gower, Emily W.; Munoz, Beatriz E.; Wang, Jiangxia; Alemayehu, Wondu; West, Sheila K.

    2010-01-01

    Purpose To evaluate the physical functioning of Ethiopian trichiasis surgery patients before and six months after surgery. Design Nested Cohort Study Methods This study was nested within the Surgery for Trichiasis, Antibiotics to Prevent Recurrence (STAR) clinical trial conducted in Ethiopia. Demographic information, ocular examinations, and physical functioning assessments were collected before and 6 months after surgery. A single score for patients’ physical functioning was constructed using Rasch analysis. A multivariate linear regression model was used to determine if change in physical functioning was associated with change in visual acuity. Results Of the 438 participants, 411 (93.8%) had both baseline and follow-up questionnaires. Physical functioning scores at baseline ranged from −6.32 (great difficulty) to +6.01 (no difficulty). The percent of participants reporting no difficulty in physical functioning increased by 32.6%; the proportion of participants in the mild/no visual impairment category increased by 8.6%. A multivariate linear regression model showed that for every line of vision gained, physical functioning improves significantly (0.09 units; 95% CI: 0.02–0.16). Conclusions Surgery to correct trichiasis appears to improve patients’ physical functioning as measured at 6 months. More effort in promoting trichiasis surgery is essential, not only to prevent corneal blindness, but also to enable improved functioning in daily life. PMID:21333268

  15. Lack of maintenance of gait pattern as measured by instrumental methods suggests psychogenic gait.

    PubMed

    Merello, Marcelo; Ballesteros, Diego; Rossi, Malco; Arena, Julieta; Crespo, Marcos; Cervio, Andres; Cuello Oderiz, Carolina; Rivero, Alberto; Cerquetti, Daniel; Risk, Marcelo; Balej, Jorge

    2012-01-01

    Fluctuation is a common feature of all psychogenic gait disorder (PGD) patterns. Whether this fluctuation involves only the degree of impairment or whether it affects the gait pattern itself remains an interesting question. We hypothesize that, on repeated measurements, both normal and abnormal gait may present quantitative differences while maintaining their basic underlying pattern; conversely, in psychogenic gait, the basic pattern appears not to be preserved. Using an optoelectronic system, data acquired from 19 normal subjects and 66 patients were applied to train a neural network (NN) and subsequently classify gait patterns into four different groups (normal, ataxic, spastic-paraparetic and parkinsonian). Five patients who fulfilled clinical criteria for psychogenic gait and six controls were then prospectively evaluated on two separate occasions, three months apart. Normal controls and ataxic, parkinsonian or spastic patients were correctly identified by the NN, and categorized within the corresponding groups at baseline as well as at a three-month follow-up evaluation. NN analysis showed that after three months, no PGD patient preserved the gait pattern detected at baseline, even though this finding was not clinically apparent. Modification of gait pattern detected by repeated kinematic measurement and NN analysis could suggest the presence of PGD, particularly in difficult-to-diagnose cases.

  16. Heart rate reactivity and current post-traumatic stress disorder when data are missing.

    PubMed

    Jeon-Slaughter, Haekyung; Tucker, Phebe; Pfefferbaum, Betty; North, Carol S; de Andrade, Bernardo Borba; Neas, Barbara

    2011-08-01

    This study demonstrates that auxiliary and exclusion criteria variables increase the effectiveness of missing imputation in correcting underestimation of physiologic reactivity in relation to post-traumatic stress disorder (PTSD) caused by deleting cases with missing physiologic data. This study used data from survivors of the 1995 Oklahoma City bombing and imputed missing heart rate data using auxiliary and exclusion criteria variables. Logistic regression was used to examine heart rate reactivity in relation to current PTSD. Of 113 survivors who participated in the bombing study's 7-year follow-up interview, 42 (37%) had missing data on heart rate reactivity due to exclusion criteria (medical illness or use of cardiovascular or psychotropic medications) or non-participation. Logistic regression results based on imputed heart rate data using exclusion criteria and auxiliary (the presence of any current PTSD arousal symptoms) variables showed that survivors with current bombing-related PTSD had significantly higher heart rates at baseline and recovered more slowly back to baseline heart rate during resting periods than survivors without current PTSD, while results based on complete cases failed to show significant correlations between current PTSD and heart rates at any assessment points. Suggested methods yielded an otherwise undetectable link between physiology and current PTSD. © 2011 The Authors. Psychiatry and Clinical Neurosciences © 2011 Japanese Society of Psychiatry and Neurology.

  17. A Randomised Controlled Trial of Efficacy of Cognitive Rehabilitation in Multiple Sclerosis: A Cognitive, Behavioural, and MRI Study.

    PubMed

    Campbell, J; Langdon, D; Cercignani, M; Rashid, W

    2016-01-01

    Aim. To explore the efficacy of home-based, computerised, cognitive rehabilitation in patients with multiple sclerosis using neuropsychological assessment and advanced structural and functional magnetic resonance imaging (fMRI). Methods. 38 patients with MS and cognitive impairment on the Brief International Cognitive Assessment for MS (BICAMS) were enrolled. Patients were randomised to undergo 45 minutes of computerised cognitive rehabilitation using RehaCom software ( n = 19) three times weekly for six weeks or to a control condition ( n = 19). Neuropsychological and MRI data were obtained at baseline (time 1), following the 6-week intervention (time 2), and after a further twelve weeks (time 3). Cortical activations were explored using fMRI and microstructural changes were explored using quantitative magnetisation transfer (QMT) imaging. Results. The treatment group showed a greater improvement in SDMT gain scores between baseline and time 2 compared to the control group ( p = 0.005). The treatment group exhibited increased activation in the bilateral prefrontal cortex and right temporoparietal regions relative to control group at time 3 ( p < 0.05 FWE  corrected ). No significant changes were observed on QMT. Conclusion. This study supports the hypothesis that home-based, computerised, cognitive rehabilitation may be effective in improving cognitive performance in patients with MS. Clinical trials registration is ISRCTN54901925.

  18. Friends Matter: Protective and Harmful Aspects of Male Friendships Associated With Past-Year Sexual Aggression in a Community Sample of Young Men

    PubMed Central

    Abbey, Antonia; Wegner, Rhiana; Pierce, Jennifer; Pegram, Sheri E.; Woerner, Jacqueline

    2015-01-01

    Objectives. We extended past research on sexual violence etiology by examining the impact of perceived pressure to have sex by any means and the types of objectifying and egalitarian language that friends used when discussing women. Methods. We examined a community sample of young single men interested in dating women (n = 423) who completed audio computer-assisted self-interviews at baseline (spring/summer 2008) and 1 year later (spring/summer 2009). We used hierarchical logistic regression analyses that controlled for baseline sexual aggression. Results. Approximately one quarter of participants (n = 108) reported that they made a woman engage in some type of sexual activity during the past year when they knew she was unwilling or unable to consent. Past-year perpetrators perceived more pressure from their friends to have sex by any means, felt less comfortable with their friends making egalitarian statements about women, and used more objectifying statements when describing how their friends talked about women compared with nonperpetrators. Seventy-eight percent of men were correctly classified by these predictors. Conclusions. Men’s discussions with each other about women could foster an environment that encourages or discourages sexual violence. We discussed future research and prevention implications. PMID:25790425

  19. Vitamin D levels and menopause-related symptoms

    PubMed Central

    LeBlanc, Erin S.; Desai, Manisha; Perrin, Nancy; Wactawski-Wende, Jean; Manson, JoAnn E.; Cauley, Jane A.; Michael, Yvonne L.; Tang, Jean; Womack, Catherine; Song, Yiqing; Johnson, Karen C.; O’Sullivan, Mary J.; Woods, Nancy; Stefanick, Marcia L.

    2015-01-01

    Objective To determine whether vitamin D levels are associated with menopause-related symptoms in older women. Methods A randomly selected subset of 1,407 women, among 26,104 potentially eligible participants of the Women’s Health Initiative Calcium and Vitamin D (CaD) trial of postmenopausal women aged 51-80 years, had 25-hydroxyvitamin D [25(OH)D] levels measured at the CaD trial baseline visit. Information about menopause-related symptoms at baseline was obtained by questionnaire and included overall number of symptoms and composite measures of sleep disturbance, emotional well-being, and energy/fatigue, as well as individual symptoms. After exclusions for missing data, 530 women [mean age 66.2 years (SD 6.8)] were included in these analyses. Results There were borderline significant associations between 25(OH)D levels and total number of menopausal symptoms (p values ranging from 0.05 to 0.06 for fully adjusted models); however, the effect was clinically insignificant and disappeared with correction for multiple testing. There were no associations between 25(OH)D levels and composite measures of sleep disturbance, emotional well-being, or energy/fatigue (p’s > 0.10 for fully adjusted models). Conclusions There was no evidence of a clinically important association between serum 25(OH)D levels and menopause-related symptoms in postmenopausal women. PMID:24736200

  20. BeiDou inter-satellite-type bias evaluation and calibration for mixed receiver attitude determination.

    PubMed

    Nadarajah, Nandakumaran; Teunissen, Peter J G; Raziq, Noor

    2013-07-22

    The Chinese BeiDou system (BDS), having different types of satellites, is an important addition to the ever growing system of Global Navigation Satellite Systems (GNSS). It consists of Geostationary Earth Orbit (GEO) satellites, Inclined Geosynchronous Satellite Orbit (IGSO) satellites and Medium Earth Orbit (MEO) satellites. This paper investigates the receiver-dependent bias between these satellite types, for which we coined the name "inter-satellite-type bias" (ISTB), and its impact on mixed receiver attitude determination. Assuming different receiver types may have different delays/biases for different satellite types, we model the differential ISTBs among three BeiDou satellite types and investigate their existence and their impact on mixed receiver attitude determination. Our analyses using the real data sets from Curtin's GNSS array consisting of different types of BeiDou enabled receivers and series of zero-baseline experiments with BeiDou-enabled receivers reveal the existence of non-zero ISTBs between different BeiDou satellite types. We then analyse the impact of these biases on BeiDou-only attitude determination using the constrained (C-)LAMBDA method, which exploits the knowledge of baseline length. Results demonstrate that these biases could seriously affect the integer ambiguity resolution for attitude determination using mixed receiver types and that a priori correction of these biases will dramatically improve the success rate.

  1. 20 g PPV with indocyanine green-assisted ILM peeling versus 23 g PPV with brilliant blue G-assisted ILM peeling for epiretinal membrane.

    PubMed

    Manousaridis, Kleanthis; Peter, Silvia; Mennel, Stefan

    2016-06-01

    To compare the anatomical and visual outcomes of 20 gauge (g) pars plana vitrectomy (PPV) with indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling and 23 g PPV with brilliant blue G (BBG)-assisted ILM peeling for idiopathic epiretinal membrane (ERM). 38 eyes of 38 patients with idiopathic ERM were included. They were divided in two groups: group 1 (18 eyes) underwent 20 g PPV with ICG-assisted ILM peeling and group 2 (20 eyes) 23 g PPV with BBG-assisted ILM peeling. Postoperative best-corrected visual acuity (BCVA) and central macular thickness (CMT) were compared. Average BCVA in group 1 improved significantly from 0.60 logarithm of the minimal angle of resolution (log MAR) at baseline to 0.3 log MAR postoperatively. Average BCVA in group 2 improved significantly from 0.60 log MAR at baseline to 0.3 log MAR postoperatively. Mean CMT reduced significantly from 473 to 375 μm in group 1 and from 486 to 396 μm in group 2. There were no significant differences in the BCVA and CMT between the groups. Both surgical methods appeared to be safe and provided similar anatomical and visual outcomes.

  2. On Drift Effects in Velocity and Displacement of Greek Uncorrected Digital Strong Motion Data

    NASA Astrophysics Data System (ADS)

    Skarlatoudis, A.; Margaris, B.

    2005-12-01

    Fifty years after the first installation of analog accelerographs, digital instruments recording the strong-motion came in operation. Their advantages comparing to the analog ones are obvious and they have been described in detail in several works. Nevertheless it has been pointed out that velocity and displacement values derived from several accelerograms, recorded in various strong earthquakes worldwide (e.g. 1999 Chi-Chi, Taiwan, Hector Mine, 2002 Denali) by digital instruments, are plagued by drifts when only a simple baseline correction derived from the pre-event portion of the record is removed. In Greece a significant number of accelerographic networks and arrays have been deployed covering the whole area. Digital accelerographs now constitute a significant part of the National Strong Motion network of the country. Detailed analyses of the data processing of accelerograms recorded by digital instruments exhibited that the same drifts exist in the Greek strong motion database. In this work, a methodology proposed and described in various articles (Boore, 2001; 2003; 2005) for removing the aforementioned drifts of the accelerograms is applied. It is also attempted a careful look of the nature of the drifts for understanding the noise characteristics relative to the signal. The intrinsic behaviour of signal to noise ratio is crucial for the adequacy of baseline corrections applied on digital uncorrected accelerograms. Velocities and displacements of the uncorrected and corrected accelerograms are compared and the drift effects in the Fourier and response spectra are presented.

  3. Item response theory analysis of the mechanics baseline test

    NASA Astrophysics Data System (ADS)

    Cardamone, Caroline N.; Abbott, Jonathan E.; Rayyan, Saif; Seaton, Daniel T.; Pawl, Andrew; Pritchard, David E.

    2012-02-01

    Item response theory is useful in both the development and evaluation of assessments and in computing standardized measures of student performance. In item response theory, individual parameters (difficulty, discrimination) for each item or question are fit by item response models. These parameters provide a means for evaluating a test and offer a better measure of student skill than a raw test score, because each skill calculation considers not only the number of questions answered correctly, but the individual properties of all questions answered. Here, we present the results from an analysis of the Mechanics Baseline Test given at MIT during 2005-2010. Using the item parameters, we identify questions on the Mechanics Baseline Test that are not effective in discriminating between MIT students of different abilities. We show that a limited subset of the highest quality questions on the Mechanics Baseline Test returns accurate measures of student skill. We compare student skills as determined by item response theory to the more traditional measurement of the raw score and show that a comparable measure of learning gain can be computed.

  4. The impact of sterile neutrinos on CP measurements at long baselines

    DOE PAGES

    Gandhi, Raj; Kayser, Boris; Masud, Mehedi; ...

    2015-09-01

    With the Deep Underground Neutrino Experiment (DUNE) as an example, we show that the presence of even one sterile neutrino of mass ~1 eV can significantly impact the measurements of CP violation in long baseline experiments. Using a probability level analysis and neutrino-antineutrino asymmetry calculations, we discuss the large magnitude of these effects, and show how they translate into significant event rate deviations at DUNE. These results demonstrate that measurements which, when interpreted in the context of the standard three family paradigm, indicate CP conservation at long baselines, may, in fact hide large CP violation if there is a sterilemore » state. Similarly, any data indicating the violation of CP cannot be properly interpreted within the standard paradigm unless the presence of sterile states of mass O(1 eV) can be conclusively ruled out. Our work underscores the need for a parallel and linked short baseline oscillation program and a highly capable near detector for DUNE, but in order that its highly anticipated results on CP violation in the lepton sector may be correctly interpreted.« less

  5. The impact of sterile neutrinos on CP measurements at long baselines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gandhi, Raj; Kayser, Boris; Masud, Mehedi

    With the Deep Underground Neutrino Experiment (DUNE) as an example, we show that the presence of even one sterile neutrino of mass ~1 eV can significantly impact the measurements of CP violation in long baseline experiments. Using a probability level analysis and neutrino-antineutrino asymmetry calculations, we discuss the large magnitude of these effects, and show how they translate into significant event rate deviations at DUNE. These results demonstrate that measurements which, when interpreted in the context of the standard three family paradigm, indicate CP conservation at long baselines, may, in fact hide large CP violation if there is a sterilemore » state. Similarly, any data indicating the violation of CP cannot be properly interpreted within the standard paradigm unless the presence of sterile states of mass O(1 eV) can be conclusively ruled out. Our work underscores the need for a parallel and linked short baseline oscillation program and a highly capable near detector for DUNE, but in order that its highly anticipated results on CP violation in the lepton sector may be correctly interpreted.« less

  6. Neuropsychological and Cognitive Correlates of Recovery in Anorexia Nervosa.

    PubMed

    Harper, Jessica A; Brodrick, Brooks; Van Enkevort, Erin; McAdams, Carrie J

    2017-11-01

    To identify clinical or cognitive measures either predictive of illness trajectory or altered with sustained weight recovery in adult women with anorexia nervosa. Participants were recruited from prior studies of women with anorexia nervosa (AN-C) and in weight-recovery following anorexia nervosa (AN-WR). Participants completed a neuropsychological battery at baseline and clinical assessments at both baseline and follow-up. Groups based on clinical outcome (continued eating disorder, AN-CC; newly in recovery, AN-CR; sustained weight-recovery, AN-WR) were compared by using one-way ANOVAs with Bonferroni-corrected post hoc comparisons. Women with continued eating disorder had poorer neuropsychological function and self-competence at baseline than AN-CR. AN-CR showed changes in depression and externalizing bias, a measure of self-related attributions. AN-WR differed from both AN-CC and AN-CR at baseline in externalizing bias, but only from AN-CC at outcome. Neuropsychological function when recently ill may be a prognostic factor, while externalizing bias may provide a clinical target for recovery. Copyright © 2017 John Wiley & Sons, Ltd and Eating Disorders Association. Copyright © 2017 John Wiley & Sons, Ltd and Eating Disorders Association.

  7. Predicting Self-Initiated Marijuana Use Cessation among Youth at Continuation High Schools.

    PubMed

    Little, Melissa A; Spruijt-Metz, Donna; Pokhrel, Pallav; Sun, Ping; Rohrbach, Louise Ann; Sussman, Steve

    2013-01-01

    The current article reports a large scale study of the prediction of marijuana use cessation among individuals attending alternative high schools who were regular users at baseline. Based on the Triadic Influence Theory, predictors of marijuana use cessation at 1-year follow-up were organized by type of influence (e.g., interpersonal, cultural and attitudinal, and intrapersonal) and level of influence (e.g., distal and ultimate). Among the 522 students who were past 30-day marijuana users at baseline, quitting was defined as having not used marijuana in the last 30 days at 1-year follow-up (43% of baseline users). To account for the level of influence we employed a theory-based analytic strategy, hierarchical regression. In the final multivariate model, lower level of baseline marijuana use and less of a likelihood to endorse pro-drug-use myths remained predictors of marijuana use cessation 1-year later. Implications of these findings include the need to develop cessation programs that reduce psychological dependence on marijuana use, and correct cognitive misperceptions about drug use in order to help adolescents make decisions that lead to health-promoting behaviors.

  8. Fast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradients.

    PubMed

    Chen, Weitian; Sica, Christopher T; Meyer, Craig H

    2008-11-01

    Off-resonance effects can cause image blurring in spiral scanning and various forms of image degradation in other MRI methods. Off-resonance effects can be caused by both B0 inhomogeneity and concomitant gradient fields. Previously developed off-resonance correction methods focus on the correction of a single source of off-resonance. This work introduces a computationally efficient method of correcting for B0 inhomogeneity and concomitant gradients simultaneously. The method is a fast alternative to conjugate phase reconstruction, with the off-resonance phase term approximated by Chebyshev polynomials. The proposed algorithm is well suited for semiautomatic off-resonance correction, which works well even with an inaccurate or low-resolution field map. The proposed algorithm is demonstrated using phantom and in vivo data sets acquired by spiral scanning. Semiautomatic off-resonance correction alone is shown to provide a moderate amount of correction for concomitant gradient field effects, in addition to B0 imhomogeneity effects. However, better correction is provided by the proposed combined method. The best results were produced using the semiautomatic version of the proposed combined method.

  9. Efficacy of intravitreal bevacizumab for macular edema following branch retinal vein occlusion stratified by baseline visual acuity.

    PubMed

    Kim, Mirae; Jeong, Seongyong; Sagong, Min

    2017-04-01

    To compare the clinical features and bevacizumab efficacy for macular edema (ME) following branch retinal vein occlusion (BRVO) stratified by baseline visual acuity. This retrospective study included a total 117 eyes from 117 consecutive patients with ME following BRVO, who received PRN intravitreal bevacizumab injection and were followed for more than 6 months. The eyes were categorized into three groups according to baseline best-corrected visual acuity (BCVA) (group A, BCVA <20/200; group B, BCVA ≥20/200 and ≤20/40; group C, BCVA >20/40). Baseline demographics, clinical features, BCVA, and central retinal thickness (CRT) at 1, 3, 6, and 12 months after injection and the number of injections were compared. Groups A-C included 11, 83, and 23 eyes, respectively. The mean baseline CRT was thickest in group A (810.1, 580.8, and 473.5 μm in groups A-C, respectively; p < 0.001) and the percentage of eyes with macular ischemia increased in the worst BCVA group (45.5, 25.0, and 4.3 % in groups A-C, respectively; p = 0.005). The mean BCVA and CRT improved at 1, 3, 6, and 12 months after treatment compared to baseline values in all groups (all, p < 0.001). The number of injections for 6 months was greater in the worst BCVA group (3.2, 2.3, and 1.9 injections in groups A-C, respectively; p = 0.009). In ME following BRVO, baseline visual acuity correlates with macular ischemia and baseline CRT. Intravitreal bevacizumab treatment results in significant anatomical and functional improvement regardless of baseline visual acuity.

  10. Improved volumetric measurement of brain structure with a distortion correction procedure using an ADNI phantom.

    PubMed

    Maikusa, Norihide; Yamashita, Fumio; Tanaka, Kenichiro; Abe, Osamu; Kawaguchi, Atsushi; Kabasawa, Hiroyuki; Chiba, Shoma; Kasahara, Akihiro; Kobayashi, Nobuhisa; Yuasa, Tetsuya; Sato, Noriko; Matsuda, Hiroshi; Iwatsubo, Takeshi

    2013-06-01

    Serial magnetic resonance imaging (MRI) images acquired from multisite and multivendor MRI scanners are widely used in measuring longitudinal structural changes in the brain. Precise and accurate measurements are important in understanding the natural progression of neurodegenerative disorders such as Alzheimer's disease. However, geometric distortions in MRI images decrease the accuracy and precision of volumetric or morphometric measurements. To solve this problem, the authors suggest a commercially available phantom-based distortion correction method that accommodates the variation in geometric distortion within MRI images obtained with multivendor MRI scanners. The authors' method is based on image warping using a polynomial function. The method detects fiducial points within a phantom image using phantom analysis software developed by the Mayo Clinic and calculates warping functions for distortion correction. To quantify the effectiveness of the authors' method, the authors corrected phantom images obtained from multivendor MRI scanners and calculated the root-mean-square (RMS) of fiducial errors and the circularity ratio as evaluation values. The authors also compared the performance of the authors' method with that of a distortion correction method based on a spherical harmonics description of the generic gradient design parameters. Moreover, the authors evaluated whether this correction improves the test-retest reproducibility of voxel-based morphometry in human studies. A Wilcoxon signed-rank test with uncorrected and corrected images was performed. The root-mean-square errors and circularity ratios for all slices significantly improved (p < 0.0001) after the authors' distortion correction. Additionally, the authors' method was significantly better than a distortion correction method based on a description of spherical harmonics in improving the distortion of root-mean-square errors (p < 0.001 and 0.0337, respectively). Moreover, the authors' method reduced the RMS error arising from gradient nonlinearity more than gradwarp methods. In human studies, the coefficient of variation of voxel-based morphometry analysis of the whole brain improved significantly from 3.46% to 2.70% after distortion correction of the whole gray matter using the authors' method (Wilcoxon signed-rank test, p < 0.05). The authors proposed a phantom-based distortion correction method to improve reproducibility in longitudinal structural brain analysis using multivendor MRI. The authors evaluated the authors' method for phantom images in terms of two geometrical values and for human images in terms of test-retest reproducibility. The results showed that distortion was corrected significantly using the authors' method. In human studies, the reproducibility of voxel-based morphometry analysis for the whole gray matter significantly improved after distortion correction using the authors' method.

  11. Evaluation of three methods for retrospective correction of vignetting on medical microscopy images utilizing two open source software tools.

    PubMed

    Babaloukas, Georgios; Tentolouris, Nicholas; Liatis, Stavros; Sklavounou, Alexandra; Perrea, Despoina

    2011-12-01

    Correction of vignetting on images obtained by a digital camera mounted on a microscope is essential before applying image analysis. The aim of this study is to evaluate three methods for retrospective correction of vignetting on medical microscopy images and compare them with a prospective correction method. One digital image from four different tissues was used and a vignetting effect was applied on each of these images. The resulted vignetted image was replicated four times and in each replica a different method for vignetting correction was applied with fiji and gimp software tools. The highest peak signal-to-noise ratio from the comparison of each method to the original image was obtained from the prospective method in all tissues. The morphological filtering method provided the highest peak signal-to-noise ratio value amongst the retrospective methods. The prospective method is suggested as the method of choice for correction of vignetting and if it is not applicable, then the morphological filtering may be suggested as the retrospective alternative method. © 2011 The Authors Journal of Microscopy © 2011 Royal Microscopical Society.

  12. In vivo serial MRI-based models and statistical methods to quantify sensitivity and specificity of mechanical predictors for carotid plaque rupture: location and beyond.

    PubMed

    Wu, Zheyang; Yang, Chun; Tang, Dalin

    2011-06-01

    It has been hypothesized that mechanical risk factors may be used to predict future atherosclerotic plaque rupture. Truly predictive methods for plaque rupture and methods to identify the best predictor(s) from all the candidates are lacking in the literature. A novel combination of computational and statistical models based on serial magnetic resonance imaging (MRI) was introduced to quantify sensitivity and specificity of mechanical predictors to identify the best candidate for plaque rupture site prediction. Serial in vivo MRI data of carotid plaque from one patient was acquired with follow-up scan showing ulceration. 3D computational fluid-structure interaction (FSI) models using both baseline and follow-up data were constructed and plaque wall stress (PWS) and strain (PWSn) and flow maximum shear stress (FSS) were extracted from all 600 matched nodal points (100 points per matched slice, baseline matching follow-up) on the lumen surface for analysis. Each of the 600 points was marked "ulcer" or "nonulcer" using follow-up scan. Predictive statistical models for each of the seven combinations of PWS, PWSn, and FSS were trained using the follow-up data and applied to the baseline data to assess their sensitivity and specificity using the 600 data points for ulcer predictions. Sensitivity of prediction is defined as the proportion of the true positive outcomes that are predicted to be positive. Specificity of prediction is defined as the proportion of the true negative outcomes that are correctly predicted to be negative. Using probability 0.3 as a threshold to infer ulcer occurrence at the prediction stage, the combination of PWS and PWSn provided the best predictive accuracy with (sensitivity, specificity) = (0.97, 0.958). Sensitivity and specificity given by PWS, PWSn, and FSS individually were (0.788, 0.968), (0.515, 0.968), and (0.758, 0.928), respectively. The proposed computational-statistical process provides a novel method and a framework to assess the sensitivity and specificity of various risk indicators and offers the potential to identify the optimized predictor for plaque rupture using serial MRI with follow-up scan showing ulceration as the gold standard for method validation. While serial MRI data with actual rupture are hard to acquire, this single-case study suggests that combination of multiple predictors may provide potential improvement to existing plaque assessment schemes. With large-scale patient studies, this predictive modeling process may provide more solid ground for rupture predictor selection strategies and methods for image-based plaque vulnerability assessment.

  13. Adaptive handling of Rayleigh and Raman scatter of fluorescence data based on evaluation of the degree of spectral overlap

    NASA Astrophysics Data System (ADS)

    Hu, Yingtian; Liu, Chao; Wang, Xiaoping; Zhao, Dongdong

    2018-06-01

    At present the general scatter handling methods are unsatisfactory when scatter and fluorescence seriously overlap in excitation emission matrix. In this study, an adaptive method for scatter handling of fluorescence data is proposed. Firstly, the Raman scatter was corrected by subtracting the baseline of deionized water which was collected in each experiment to adapt to the intensity fluctuations. Then, the degrees of spectral overlap between Rayleigh scatter and fluorescence were classified into three categories based on the distance between the spectral peaks. The corresponding algorithms, including setting to zero, fitting on single or both sides, were implemented after the evaluation of the degree of overlap for individual emission spectra. The proposed method minimized the number of fitting and interpolation processes, which reduced complexity, saved time, avoided overfitting, and most importantly assured the authenticity of data. Furthermore, the effectiveness of this procedure on the subsequent PARAFAC analysis was assessed and compared to Delaunay interpolation by conducting experiments with four typical organic chemicals and real water samples. Using this method, we conducted long-term monitoring of tap water and river water near a dyeing and printing plant. This method can be used for improving adaptability and accuracy in the scatter handling of fluorescence data.

  14. Transmission FTIR derivative spectroscopy for estimation of furosemide in raw material and tablet dosage form

    PubMed Central

    Gallignani, Máximo; Rondón, Rebeca A.; Ovalles, José F.; Brunetto, María R.

    2014-01-01

    A Fourier transform infrared derivative spectroscopy (FTIR-DS) method has been developed for determining furosemide (FUR) in pharmaceutical solid dosage form. The method involves the extraction of FUR from tablets with N,N-dimethylformamide by sonication and direct measurement in liquid phase mode using a reduced path length cell. In general, the spectra were measured in transmission mode and the equipment was configured to collect a spectrum at 4 cm−1 resolution and a 13 s collection time (10 scans co-added). The spectra were collected between 1400 cm−1 and 450 cm−1. Derivative spectroscopy was used for data processing and quantitative measurement using the peak area of the second order spectrum of the major spectral band found at 1165 cm−1 (SO2 stretching of FUR) with baseline correction. The method fulfilled most validation requirements in the 2 mg/mL and 20 mg/mL range, with a 0.9998 coefficient of determination obtained by simple calibration model, and a general coefficient of variation <2%. The mean recovery for the proposed assay method resulted within the (100±3)% over the 80%–120% range of the target concentration. The results agree with a pharmacopoeial method and, therefore, could be considered interchangeable. PMID:26579407

  15. RISK FACTORS FOR FOUR-YEAR INCIDENT VISUAL IMPAIRMENT AND BLINDNESS: THE LOS ANGELES LATINO EYE STUDY

    PubMed Central

    Yonekawa, Yoshihiro; Varma, Rohit; Choudhury, Farzana; Torres, Mina; Azen, Stanley P.

    2016-01-01

    Purpose To identify independent risk factors for incident visual impairment (VI) and monocular blindness. Design Population-based prospective cohort study. Participants 4,658 Latinos aged 40 years in the Los Angeles Latino Eye Study (LALES) Methods A detailed history and comprehensive ophthalmological examination was performed at baseline and at the 4-year follow-up on 4,658 Latinos aged 40 years and older from Los Angeles, California. Incident VI was defined as best corrected visual acuity (BCVA) of <20/40 and >20/200 in the better-seeing eye at the 4 year follow-up examination in persons who had a BCVA of ≥20/40 in the better seeing eye at baseline. Incident monocular blindness was defined as BCVA of ≤20/200 in one eye at follow-up in persons who had a BCVA >20/200 in both eyes at baseline. Socio-demographic and clinical risk factors identified at the baseline interview and examination and associated with incident VI and loss of vision were determined using multivariable regression. Odds ratios (OR) were calculated for those variables that were independently associated with visual impairment and monocular blindness. Main Outcome Measures ORs for various risk factors for incident VI and monocular blindness Results Independent risk factors for incident VI were older age (70–79 years OR=4.8, ≥80 years OR=17.9), being unemployment (OR=3.5), and having diabetes mellitus (OR=2.2). Independent risk factors for monocular blindness were being retired (OR=3.4) or widowed (OR=3.7), having diabetes mellitus (OR=2.1) or any ocular disease (OR=5.6) at baseline. Persons with self-reported excellent/good vision were less likely to develop VI or monocular blindness (OR=0.4–0.5). Conclusion Our data highlight that older Latinos and Latinos with diabetes mellitus or self-reported eye diseases are at high risk of developing vision loss. Furthermore, being unemployed, widowed or retired confers an independent risk of monocular blindness. Interventions that prevent, treat, and focus on the modifiable factors may reduce the burden of vision loss in this fastest growing segment of the United States population. PMID:21788079

  16. Staircase-scene-based nonuniformity correction in aerial point target detection systems.

    PubMed

    Huo, Lijun; Zhou, Dabiao; Wang, Dejiang; Liu, Rang; He, Bin

    2016-09-01

    Focal-plane arrays (FPAs) are often interfered by heavy fixed-pattern noise, which severely degrades the detection rate and increases the false alarms in airborne point target detection systems. Thus, high-precision nonuniformity correction is an essential preprocessing step. In this paper, a new nonuniformity correction method is proposed based on a staircase scene. This correction method can compensate for the nonlinear response of the detector and calibrate the entire optical system with computational efficiency and implementation simplicity. Then, a proof-of-concept point target detection system is established with a long-wave Sofradir FPA. Finally, the local standard deviation of the corrected image and the signal-to-clutter ratio of the Airy disk of a Boeing B738 are measured to evaluate the performance of the proposed nonuniformity correction method. Our experimental results demonstrate that the proposed correction method achieves high-quality corrections.

  17. Removing Batch Effects from Longitudinal Gene Expression - Quantile Normalization Plus ComBat as Best Approach for Microarray Transcriptome Data

    PubMed Central

    Müller, Christian; Schillert, Arne; Röthemeier, Caroline; Trégouët, David-Alexandre; Proust, Carole; Binder, Harald; Pfeiffer, Norbert; Beutel, Manfred; Lackner, Karl J.; Schnabel, Renate B.; Tiret, Laurence; Wild, Philipp S.; Blankenberg, Stefan

    2016-01-01

    Technical variation plays an important role in microarray-based gene expression studies, and batch effects explain a large proportion of this noise. It is therefore mandatory to eliminate technical variation while maintaining biological variability. Several strategies have been proposed for the removal of batch effects, although they have not been evaluated in large-scale longitudinal gene expression data. In this study, we aimed at identifying a suitable method for batch effect removal in a large study of microarray-based longitudinal gene expression. Monocytic gene expression was measured in 1092 participants of the Gutenberg Health Study at baseline and 5-year follow up. Replicates of selected samples were measured at both time points to identify technical variability. Deming regression, Passing-Bablok regression, linear mixed models, non-linear models as well as ReplicateRUV and ComBat were applied to eliminate batch effects between replicates. In a second step, quantile normalization prior to batch effect correction was performed for each method. Technical variation between batches was evaluated by principal component analysis. Associations between body mass index and transcriptomes were calculated before and after batch removal. Results from association analyses were compared to evaluate maintenance of biological variability. Quantile normalization, separately performed in each batch, combined with ComBat successfully reduced batch effects and maintained biological variability. ReplicateRUV performed perfectly in the replicate data subset of the study, but failed when applied to all samples. All other methods did not substantially reduce batch effects in the replicate data subset. Quantile normalization plus ComBat appears to be a valuable approach for batch correction in longitudinal gene expression data. PMID:27272489

  18. Spoken Language Processing in the Clarissa Procedure Browser

    NASA Technical Reports Server (NTRS)

    Rayner, M.; Hockey, B. A.; Renders, J.-M.; Chatzichrisafis, N.; Farrell, K.

    2005-01-01

    Clarissa, an experimental voice enabled procedure browser that has recently been deployed on the International Space Station, is as far as we know the first spoken dialog system in space. We describe the objectives of the Clarissa project and the system's architecture. In particular, we focus on three key problems: grammar-based speech recognition using the Regulus toolkit; methods for open mic speech recognition; and robust side-effect free dialogue management for handling undos, corrections and confirmations. We first describe the grammar-based recogniser we have build using Regulus, and report experiments where we compare it against a class N-gram recogniser trained off the same 3297 utterance dataset. We obtained a 15% relative improvement in WER and a 37% improvement in semantic error rate. The grammar-based recogniser moreover outperforms the class N-gram version for utterances of all lengths from 1 to 9 words inclusive. The central problem in building an open-mic speech recognition system is being able to distinguish between commands directed at the system, and other material (cross-talk), which should be rejected. Most spoken dialogue systems make the accept/reject decision by applying a threshold to the recognition confidence score. NASA shows how a simple and general method, based on standard approaches to document classification using Support Vector Machines, can give substantially better performance, and report experiments showing a relative reduction in the task-level error rate by about 25% compared to the baseline confidence threshold method. Finally, we describe a general side-effect free dialogue management architecture that we have implemented in Clarissa, which extends the "update semantics'' framework by including task as well as dialogue information in the information state. We show that this enables elegant treatments of several dialogue management problems, including corrections, confirmations, querying of the environment, and regression testing.

  19. Hepatitis C videoconferencing: the impact on continuing medical education for rural healthcare providers.

    PubMed

    Rossaro, Lorenzo; Tran, Thu P; Ransibrahmanakul, Kanat; Rainwater, Julie A; Csik, Genell; Cole, Stacey L; Prosser, Colette C; Nesbitt, Thomas S

    2007-06-01

    This study compared the impact of multipoint videoconferencing (VC) versus standard lecturing (ST) on primary care providers' (MDs, NPs/PAs, and RNs) education regarding hepatitis C virus (HCV). The hypothesis was that the educational impact of teaching through telemedicine is comparable to the traditional method. The aim was to provide participants clinically relevant information and knowledge about the natural history, diagnosis, and management of HCV. Improved knowledge was scored from a 10-item quiz administered before and after the educational intervention. Comparison of the pretest knowledge scores within provider groups showed no statistically significant difference in baseline knowledge for the ST versus VC method. However, for all practitioners combined, the VC group scored significantly lower on the pretest than the ST group (p < 0.05). All three types of learners improved their knowledge scores following intervention. On average, MDs and NP/PAs correctly answered two to 3.5 more questions in the posttest. RNs showed the greatest improvements, correctly answering an average of four to five more questions following intervention. Improvement in knowledge scores between the two methods was statistically significant in favor of VC for the MDs (VC = 3.56 +/- 1.92 vs. ST = 2.13 +/- 1.89, p < 0.001) and all groups combined (VC 4.37 +/- 1.92 vs ST 3.06 +/- 1.89, p < 0.001). The results of this study indicate that VC is equivalent, if not better, than standard continuing medical education (CME). VC can potentially improve clinician education regarding the history, diagnosis, and management of HCV, thereby making a substantial impact on the clinical course of patients with this condition. In addition, VC has the potential to eliminate the financial and geographic barriers to professional education for rural practitioners.

  20. Non-destructive and fast identification of cotton-polyester blend fabrics by the portable near-infrared spectrometer.

    PubMed

    Li, Wen-xia; Li, Feng; Zhao, Guo-liang; Tang, Shi-jun; Liu, Xiao-ying

    2014-12-01

    A series of 376 cotton-polyester (PET) blend fabrics were studied by a portable near-infrared (NIR) spectrometer. A NIR semi-quantitative-qualitative calibration model was established by Partial Least Squares (PLS) method combined with qualitative identification coefficient. In this process, PLS method in a quantitative analysis was used as a correction method, and the qualitative identification coefficient was set by the content of cotton and polyester in blend fabrics. Cotton-polyester blend fabrics were identified qualitatively by the model and their relative contents were obtained quantitatively, the model can be used for semi-quantitative identification analysis. In the course of establishing the model, the noise and baseline drift of the spectra were eliminated by Savitzky-Golay(S-G) derivative. The influence of waveband selection and different pre-processing method was also studied in the qualitative calibration model. The major absorption bands of 100% cotton samples were in the 1400~1600 nm region, and the one for 100% polyester were around 1600~1800 nm, the absorption intensity was enhancing with the content increasing of cotton or polyester. Therefore, the cotton-polyester's major absorption region was selected as the base waveband, the optimal waveband (1100~2500 nm) was found by expanding the waveband in two directions (the correlation coefficient was 0.6, and wave-point number was 934). The validation samples were predicted by the calibration model, the results showed that the model evaluation parameters was optimum in the 1100~2500 nm region, and the combination of S-G derivative, multiplicative scatter correction (MSC) and mean centering was used as the pre-processing method. RC (relational coefficient of calibration) value was 0.978, RP (relational coefficient of prediction) value was 0.940, SEC (standard error of calibration) value was 1.264, SEP (standard error of prediction) value was 1.590, and the sample's recognition accuracy was up to 93.4%. It showed that the cotton-polyester blend fabrics could be predicted by the semi-quantitative-qualitative calibration model.

Top