Sample records for baseplate central plug

  1. Reverse shoulder arthroplasty glenoid fixation: is there a benefit in using four instead of two screws?

    PubMed

    James, Jaison; Allison, Mari A; Werner, Frederick W; McBride, Devin E; Basu, Niladri N; Sutton, Levi G; Nanavati, Vipul N

    2013-08-01

    To allow osseous integration to occur and thus provide long-term stability, initial glenoid baseplate fixation must be sufficiently rigid. A major contributing factor to initial rigid fixation is baseplate screw fixation. Current baseplate designs use a 4-screw fixation construct. However, recent literature suggests adequate fixation can be achieved with fewer than 4 screws. The purpose of the present study was to determine whether a 4-screw construct provides more baseplate stability than a 2-screw construct. A flat-backed glenoid baseplate with 4 screw hole options was implanted into 6 matched pairs of cadaver scapulas using standard surgical technique. Within each pair, 2 screws or 4 screws were implanted in a randomized fashion. A glenosphere was attached allowing cyclic loading in an inferior-to-superior direction and in an anterior-to-posterior direction. Baseplate motion was measured using 4 linear voltage displacement transducers evenly spaced around the glenosphere. There was no statistical difference in the average peak central displacements between fixation with 2 or 4 screws (P = .338). Statistical increases in average peak central displacement with increasing load (P < .001) and with repetitive loading (P < .002) were found. This study demonstrates no statistical difference in baseplate motion between 2-screw and 4-screw constructs. Therefore, using fewer screws could potentially lead to a reduction in operative time, cost, and risk, with no significant negative effect on overall implant baseplate motion. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  2. The Structure of Gene Product 6 of Bacteriophage T4, the Hinge-Pin of the Baseplate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aksyuk, Anastasia A.; Leiman, Petr G.; Shneider, Mikhail M.

    2009-07-21

    The baseplate of bacteriophage T4 is a multicomponent protein complex, which controls phage attachment to the host. It assembles from six wedges and a central hub. During infection the baseplate undergoes a large conformational change from a dome-shaped to a flat, star-shaped structure. We report the crystal structure of the C-terminal half of gene product (gp) 6 and investigate its motion with respect to the other proteins during the baseplate rearrangement. Six gp6 dimers interdigitate, forming a ring that maintains the integrity of the baseplate in both conformations. One baseplate wedge contains an N-terminal dimer of gp6, whereas neighboring wedgesmore » are tied together through the C-terminal dimer of gp6. The dimeric interactions are preserved throughout the rearrangement of the baseplate. However, the hinge angle between the N- and C-terminal parts of gp6 changes by {approx}15{sup o}, accounting for a 10 {angstrom} radial increase in the diameter of the gp6 ring.« less

  3. Comparison of the primary stability of different tibial baseplate concepts to retain both cruciate ligaments during total knee arthroplasty.

    PubMed

    Nowakowski, Andrej M; Stangel, Melanie; Grupp, Thomas M; Valderrabano, Victor

    2013-10-01

    A novel tibial baseplate design (Transversal Support Tibial Plateau) as a new treatment concept for bi-cruciate retaining total knee arthroplasty is evaluated for mechanical stability and compared to other tibial baseplate designs. This concept should provide better primary stability and thus, less subsidence, than implantation of two separate unicondylar tibial baseplates. Different baseplates were implanted into synthetic bone specimens (Sawbones® Pacific Research Laboratories, Inc., Washington, USA), all uncemented. Using a standardized experimental setup, subsidence was achieved, enabling comparison of the models regarding primary stability. Overall implant subsidence was significantly increased for the two separate unicondylar tibial baseplates versus the new Transversal Support Tibial Plateau concept, which showed comparable levels to a conventional tibial baseplate. Reduced subsidence results in better primary stability. Linking of two separate baseplates appears to provide increased primary stability in terms of bony fixation, comparable to that of a conventional single tibial baseplate. © 2013. Published by Elsevier Ltd. All rights reserved.

  4. Reverse shoulder glenoid baseplate fixation: a comparison of flat-back versus curved-back designs and oval versus circular designs with 2 different offset glenospheres.

    PubMed

    Roche, Christopher P; Stroud, Nicholas J; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; DiPaola, Matthew J

    2014-09-01

    In this glenoid loosening study, we compared the fixation strength of multiple generic reverse shoulder glenoid baseplates that differed only in backside geometry and shape and size to optimize design from a fixation perspective. The fixation strength of 4 generic baseplates was quantified in a low-density polyurethane substrate to isolate the contribution of baseplate profile and size (25 mm circular vs 25 × 34 mm oval) and backside geometry (flat back vs curved back) on fixation using 2 center-of-rotation glenospheres (0 mm and 10 mm lateral). The cyclic test simulated 55° of abduction as a 750 N load was continuously applied to induce a variable shear and compressive load. Before and after cyclic loading, baseplate displacement was measured in the directions of the applied static shear and compressive loads. Each generic baseplate was cyclically tested 7 times with each offset glenosphere for a total of 56 samples. Circular baseplates were associated with significantly more shear displacement in both the superior-inferior (SI) and anterior-posterior (AP) directions after cyclic loading than oval baseplates. No such significant differences in fixation were observed between flat-back and curved-back baseplates. Circular baseplates were also associated with significantly more SI and AP shear displacement with 10 mm glenospheres than with 0 mm glenospheres. No significant difference in SI or AP motion was observed with oval baseplates between 0 mm and 10 mm glenospheres. Our results suggest that baseplate shape and size affects fixation strength more than backside geometry. The 25 × 34 mm oval baseplates showed better fixation characteristics than their 25 mm circular counterparts; no discernible difference in fixation was observed between flat-back and curved-back baseplates. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  5. Effect of baseplate size on primary glenoid stability and impingement-free range of motion in reverse shoulder arthroplasty.

    PubMed

    Chae, Soo-Won; Kim, Soung-Yon; Lee, Haea; Yon, Joung-Ro; Lee, Juneyoung; Han, Seung-Ho

    2014-12-09

    Use of a baseplate with a smaller diameter in reverse shoulder arthroplasty is increasing, especially in patients with a small glenoid or glenoid wear. However, the effect of a smaller baseplate on stability of the glenoid component has not been evaluated. Thus, the purpose of this study was to determine whether a smaller baseplate (25 mm) is beneficial to the initial stability of the glenoid component compared to that with a baseplate of a commonly used size (29 mm). Micromotion of glenoid components attached to 14 scapulae of fresh-frozen cadavers was measured and compared between 25- and 29-mm baseplates in biomechanical testing. Impingement-free range of motion in abduction, adduction, internal rotation, and external rotation was evaluated by using a simulated computer model constructed based on the same fresh-frozen cadavers used in biomechanical testing. Micromotion at the inferior third of the glenoid-glenosphere interface was higher in the 29-mm baseplate group than in the 25-mm baseplate group during both 0.7- and 1-body weight cyclic loading in biomechanical testing. Adduction deficit was smaller, and total impingement-free range of motion from abduction to adduction and rotation were greater in the 25-mm baseplate group than in the 29-mm baseplate group in the simulated computer model. Use of a baseplate with a smaller diameter (25 mm) in reverse shoulder arthroplasty is suitable for improving the primary stability of the glenoid component. With a smaller baseplate, impingement-free range of motion is optimized in a smaller glenoid.

  6. Bone Grafting the Glenoid Versus Use of Augmented Glenoid Baseplates with Reverse Shoulder Arthroplasty.

    PubMed

    Jones, Richard B; Wright, Thomas W; Roche, Christopher P

    2015-12-01

    Large glenoid defects are a difficult reconstructive problem for surgeons performing reverse shoulder arthroplasty (rTSA). Options to address glenoid defects include eccentric reaming, bone grafting, and augmented glenoid baseplates. Augmented glenoid baseplates may provide a simpler, cost-effective, bone-preserving option compared to other techniques. No studies report the use of augmented baseplates to correct glenoid deformity in rTSA relative to the use of glenoid bone graft. We retrospectively reviewed 80 patients that received a primary rTSA and received either a structural bone graft or an augmented glenoid baseplate to address a significant glenoid defect. There were 39 patients in the augmented baseplate cohort and 41 patients in the bone graft cohort. The augmented baseplate cohort contained 24 8° posterior augment implants and 15 10° superior augment baseplates. The bone graft cohort consisted of 36 autograft humeral heads and 5 allograft femoral heads. The average follow-up for rTSA patients with an augmented baseplate was 28.3 ± 5.7 months, and the average follow-up for rTSA patients with glenoid bone graft was 34.1 ± 15.0 months. Each patient was scored preoperatively and at latest follow-up using the SST, UCLA, ASES, Constant, and SPADI metrics. Range of motion data was obtained as well. All patients demonstrated significant improvements in pain, ROM, and functional scores following treatment with rTSA using either augmented baseplates or glenoid bone graft to correct glenoid defects. The database contained no complications for the augmented glenoid baseplate cohort, and six complications (14.6%) for the glenoid bone graft cohort (including two glenoid loosenings and graft failures). Additionally, the augmented baseplate cohort showed a lower scapular notching rate of 10% as compared to the bone graft cohort which had a notching rate of 18.5%. The results of this study suggest that either augmented glenoid baseplates or glenoid bone graft can be used to address large glenoid defects during rTSA with significant improvement in outcomes. Augmented glenoid baseplates may achieve a lower complication and scapular notching rate, but additional and longer-term clinical follow-up is required to confirm these results.

  7. Tightening force and torque of nonlocking screws in a reverse shoulder prosthesis.

    PubMed

    Terrier, A; Kochbeck, S H; Merlini, F; Gortchacow, M; Pioletti, D P; Farron, A

    2010-07-01

    Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  8. Reverse total shoulder arthroplasty using helical blade to optimize glenoid fixation and bone preservation: preliminary results in thirty five patients with minimum two year follow-up.

    PubMed

    Zilber, Sebastien; Camana, Eleonora; Lapner, Peter; Haritinian, Emil; Nove Josserand, Laurent

    2018-03-26

    Glenoid loosening is a common cause of reverse total shoulder arthroplasty (RTSA) failure, and grafting of the glenoid is often required for revision due to bone loss due to the central peg in most glenoid baseplates. Helical blades have been used in the hip to optimize bone fixation in proximal femoral fracture. This study presents the initial results of specifically designed helical blade in the shoulder to optimize glenoid bone fixation and preservation as part of RTSA. Thirty-five patients underwent RTSA with glenoid helical blade fixation. An uncemented glenoid baseplate was used with a central helical blade partially coated with hydroxyapatite and two or three screws. Outcome analysis was performed pre-operatively and at two years. All patients were satisfied with the results and significant improvement was observed in functional outcome scores between baseline and final follow-up. There was a single intra-operative undisplaced glenoid fracture which did not compromise the baseplate fixation. There was no radiographic evidence of loosening or radiolucencies around the helical blade. The helical blade provides a satisfactory primary fixation. Because of its length (21 mm), care should be taken in cases of pre-existing bone loss or sclerotic bone to avoid glenoid fracture or anterior cortical perforation. Helical blade has the potential to facilitate glenoid implant revision by preserving the glenoid bone stock.

  9. Remote repair appliance

    DOEpatents

    Heumann, Frederick K.; Wilkinson, Jay C.; Wooding, David R.

    1997-01-01

    A remote appliance for supporting a tool for performing work at a worksite on a substantially circular bore of a workpiece and for providing video signals of the worksite to a remote monitor comprising: a baseplate having an inner face and an outer face; a plurality of rollers, wherein each roller is rotatably and adjustably attached to the inner face of the baseplate and positioned to roll against the bore of the workpiece when the baseplate is positioned against the mouth of the bore such that the appliance may be rotated about the bore in a plane substantially parallel to the baseplate; a tool holding means for supporting the tool, the tool holding means being adjustably attached to the outer face of the baseplate such that the working end of the tool is positioned on the inner face side of the baseplate; a camera for providing video signals of the worksite to the remote monitor; and a camera holding means for supporting the camera on the inner face side of the baseplate, the camera holding means being adjustably attached to the outer face of the baseplate. In a preferred embodiment, roller guards are provided to protect the rollers from debris and a bore guard is provided to protect the bore from wear by the rollers and damage from debris.

  10. Electrostatic spring softening in redundant degree of freedom resonators

    NASA Technical Reports Server (NTRS)

    Hayworth, Ken J. (Inventor); Shcheglov, Kirill V. (Inventor); Humphreys, Todd E. (Inventor); Challoner, A. Dorian (Inventor)

    2004-01-01

    The present invention discloses an isolated electrostatic biased resonator gyroscope. The gyroscope includes an isolated resonator having a first and a second differential vibration mode, a baseplate supporting the isolated resonator, a plurality of excitation affixed to the baseplate for exciting the first differential vibration mode, a plurality of sensing electrodes affixed to the baseplate for sensing movement of the gyroscope through the second differential vibration mode and a plurality of bias electrodes affixed to the baseplate for trimming isolation of the resonator and substantially minimizing frequency split between the first and second differential vibration modes. Typically, the isolated resonator comprises a proof mass and a counterbalancing plate with the bias electrodes disposed on the baseplate below.

  11. Tibial interface wear in retrieved total knee components and correlations with modular insert motion.

    PubMed

    Rao, Anand R; Engh, Gerard A; Collier, Matthew B; Lounici, Smain

    2002-10-01

    Wear occurring at the interface between the polyethylene insert and metal baseplate of a modular tibial component has become an increasingly common finding at the time of revision total knee arthroplasty. Although this so-called backside wear on retrieved polyethylene inserts has been evaluated in prior studies, wear on retrieved metal baseplates has not been described, to our knowledge. The purposes of the present study were to characterize backside wear on retrieved polyethylene inserts and on the mating surfaces of their corresponding baseplates and to investigate if there is a relationship between backside wear and relative motion of the modular elements. Twenty-nine retrieved modular tibial components of twelve fixed-bearing designs were analyzed in vitro with regard to backside wear and relative motion between the polyethylene insert and the metal baseplate. We graded the backside of each polyethylene insert and the mating surface of the metal baseplate for wear with use of a scoring system that consisted of three modes of wear and three levels of severity of wear. Relative motion between the insert and the baseplate was measured in the transverse plane with use of a mechanical testing machine. These measurements were used to compute the insert motion index, which served to quantify unrestricted motion of the insert with respect to the baseplate. The mean insert motion index for the tibial components was 416 micro m (range, 104 micro m to 760 micro m). On a wear-grading scale ranging from 0 to 54 (with 0 indicating no wear), the mean backside wear score was 30 (range, 12 to 48) for the inserts and 28 (range, 7 to 51) for the baseplates. Insert motion was positively correlated with backside polyethylene wear (p = 0.003) and baseplate wear (p < 0.001). Baseplate wear was strongly correlated with backside polyethylene wear (p < 0.001). Backside wear was correlated with the relative motion between the polyethylene insert and the metal baseplate. New locking mechanism designs directed toward better methods of securing the polyethylene insert to the tibial tray are needed to minimize the generation of particulate wear debris at the modular interface.

  12. Low-Thermal-Resistance Baseplate Mounting

    NASA Technical Reports Server (NTRS)

    Perreault, W. T.

    1984-01-01

    Low-thermal-resistance mounting achieved by preloading baseplate to slight convexity with screws threaded through beam. As mounting bolts around edge of base-place tightened, baseplate and cold plate contact first in center, with region of intimate contact spreading outward as bolts tightened.

  13. Friction pull plug welding: chamfered heat sink pull plug design

    NASA Technical Reports Server (NTRS)

    Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)

    2002-01-01

    Friction Pull Plug Welding (FPPW) is a solid state repair process for defects up to one inch in length, only requiring single sided tooling (OSL) for usage on flight hardware. Experimental data has shown that the mass of plug heat sink remaining above the top of the plate surface after a weld is completed (the plug heat sink) affects the bonding at the plug top. A minimized heat sink ensures complete bonding of the plug to the plate at the plug top. However, with a minimal heat sink three major problems can arise, the entire plug could be pulled through the plate hole, the central portion of the plug could be separated along grain boundaries, or the plug top hat can be separated from the body. The Chamfered Heat Sink Pull Plug Design allows for complete bonding along the ISL interface through an outside diameter minimal mass heat sink, while maintaining enough central mass in the plug to prevent plug pull through, central separation, and plug top hat separation.

  14. Reverse total shoulder glenoid baseplate stability with superior glenoid bone loss.

    PubMed

    Martin, Elise J; Duquin, Thomas R; Ehrensberger, Mark T

    2017-10-01

    Superior wear of the glenoid bone is common in patients with rotator cuff arthropathy. This can become a treatment challenge for patients who require shoulder arthroplasty. In reverse shoulder arthroplasty (RSA), glenoid bone loss may affect the stability of baseplate fixation. The primary purpose of this biomechanical laboratory study was to assess the initial fixation stability of RSA glenosphere baseplates in the presence of variable amounts of superior glenoid bone loss. High-density solid rigid polyurethane foam (30 pounds/cubic foot) was machined to model the glenoid with variable superior defects that provided different levels of support (100%, 90%, 75%, and 50%) for the glenosphere baseplate. The samples were cyclically loaded (0-750 N at 1 Hz for 5000 cycles) at a 60° glenohumeral angle. The micromotion and migration of the baseplate were calculated from displacement data captured during the loading tests with an array of 3 linear variable differential transformers mounted around the baseplate. Micromotion was significantly greater in samples with 50% defects compared with those with smaller defects. Migration was significantly greater after testing for all defect sizes. Initial fixation of RSA glenosphere baseplates was significantly reduced in models with 50% bone loss on the superior edge compared with models with less bone loss in this high-density bone foam model. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. Optimal baseplate rotational alignment for locking-screw fixation in reverse total shoulder arthroplasty: a three-dimensional computer-aided design study.

    PubMed

    Stephens, Byron F; Hebert, Casey T; Azar, Frederick M; Mihalko, William M; Throckmorton, Thomas W

    2015-09-01

    Baseplate loosening in reverse total shoulder arthroplasty (RTSA) remains a concern. Placing peripheral screws into the 3 pillars of the densest scapular bone is believed to optimize baseplate fixation. Using a 3-dimensional computer-aided design (3D CAD) program, we investigated the optimal rotational baseplate alignment to maximize peripheral locking-screw purchase. Seventy-three arthritic scapulae were reconstructed from computed tomography images and imported into a 3D CAD software program along with representations of an RTSA baseplate that uses 4 fixed-angle peripheral locking screws. The baseplate position was standardized, and the baseplate was rotated to maximize individual and combined peripheral locking-screw purchase in each of the 3 scapular pillars. The mean ± standard error of the mean positions for optimal individual peripheral locking-screw placement (referenced in internal rotation) were 6° ± 2° for the coracoid pillar, 198° ± 2° for the inferior pillar, and 295° ± 3° for the scapular spine pillar. Of note, 78% (57 of 73) of the screws attempting to obtain purchase in the scapular spine pillar could not be placed without an in-out-in configuration. In contrast, 100% of coracoid and 99% of inferior pillar screws achieved full purchase. The position of combined maximal fixation was 11° ± 1°. These results suggest that approximately 11° of internal rotation is the ideal baseplate position for maximal peripheral locking-screw fixation in RTSA. In addition, these results highlight the difficulty in obtaining optimal purchase in the scapular spine. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Isolated resonator gyroscope with isolation trimming using a secondary element

    NASA Technical Reports Server (NTRS)

    Challoner, A. Dorian (Inventor); Shcheglov, Kirill V. (Inventor)

    2006-01-01

    The present invention discloses a resonator gyroscope including an isolated resonator. One or more flexures support the isolated resonator and a baseplate is affixed to the resonator by the flexures. Drive and sense elements are affixed to the baseplate and used to excite the resonator and sense movement of the gyroscope. In addition, at least one secondary element (e.g., another electrode) is affixed to the baseplate and used for trimming isolation of the resonator. The resonator operates such that it transfers substantially no net momentum to the baseplate when the resonator is excited. Typically, the isolated resonator comprises a proof mass and a counterbalancing plate.

  17. Friction Pull Plug and Material Configuration for Anti-Chatter Friction Pull Plug Weld

    NASA Technical Reports Server (NTRS)

    Littell, Justin Anderson (Inventor)

    2016-01-01

    A friction pull plug is provided for use in forming a plug weld in a hole in a material. The friction pull plug includes a shank and a series of three frustoconical sections. The relative sizes of the sections assure that a central one of the sections defines the initial contact point between the hole's sides. The angle defined by the central one of the sections reduces or eliminates chatter as the plug is pulled into the hole.

  18. Eddy Current Minimizing Flow Plug for Use in Flow Conditioning and Flow Metering

    NASA Technical Reports Server (NTRS)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor)

    2015-01-01

    An eddy-current-minimizing flow plug has an outer radial wall with open flow channels formed between the plug's inlet and outlet. The plug has a central region coupled to the inner surface of the outer radial wall. Each open flow channel includes (i) a first portion originating at the inlet and converging to a location in the plug where convergence is contributed to by changes in thickness of the outer radial wall and divergence of the central region, and (ii) a second portion originating in the plug and diverging to the outlet where divergence is contributed to by changes in thickness of the outer radial wall and convergence of the central region. For at least a portion of the open flow channels, a central axis passing through the first and second portions is non-parallel with respect to the given direction of the flow.

  19. Silicon base plate with low parasitic electrical interference for sensors

    NASA Technical Reports Server (NTRS)

    Tang, Tony K. (Inventor); Gutierrez, Roman C. (Inventor)

    2002-01-01

    A microgyroscope has a baseplate made of the same material as the rest of the microgyroscope. The baseplate is a silicon baseplate having a heavily p-doped epilayer covered by a thick dielectric film and metal electrodes. The metal electrodes are isolated from the ground plane by the dielectric. This provides very low parasitic capacitive coupling between the electrodes. The thick dielectric reduces the capacitance between the electrodes and the ground plane.

  20. Comparing conventional and computer-assisted surgery baseplate and screw placement in reverse shoulder arthroplasty.

    PubMed

    Venne, Gabriel; Rasquinha, Brian J; Pichora, David; Ellis, Randy E; Bicknell, Ryan

    2015-07-01

    Preoperative planning and intraoperative navigation technologies have each been shown separately to be beneficial for optimizing screw and baseplate positioning in reverse shoulder arthroplasty (RSA) but to date have not been combined. This study describes development of a system for performing computer-assisted RSA glenoid baseplate and screw placement, including preoperative planning, intraoperative navigation, and postoperative evaluation, and compares this system with a conventional approach. We used a custom-designed system allowing computed tomography (CT)-based preoperative planning, intraoperative navigation, and postoperative evaluation. Five orthopedic surgeons defined common preoperative plans on 3-dimensional CT reconstructed cadaveric shoulders. Each surgeon performed 3 computer-assisted and 3 conventional simulated procedures. The 3-dimensional CT reconstructed postoperative units were digitally matched to the preoperative model for evaluation of entry points, end points, and angulations of screws and baseplate. Values were used to find accuracy and precision of the 2 groups with respect to the defined placement. Statistical analysis was performed by t tests (α = .05). Comparison of the groups revealed no difference in accuracy or precision of screws or baseplate entry points (P > .05). Accuracy and precision were improved with use of navigation for end points and angulations of 3 screws (P < .05). Accuracy of the inferior screw showed a trend of improvement with navigation (P > .05). Navigated baseplate end point precision was improved (P < .05), with a trend toward improved accuracy (P > .05). We conclude that CT-based preoperative planning and intraoperative navigation allow improved accuracy and precision for screw placement and precision for baseplate positioning with respect to a predefined placement compared with conventional techniques in RSA. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Achieving fixation in glenoids with superior wear using reverse shoulder arthroplasty.

    PubMed

    Roche, Christopher P; Stroud, Nicholas J; Martin, Brian L; Steiler, Cindy A; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; Dipaola, Matthew J

    2013-12-01

    Superior glenoid wear is a common challenge with reverse shoulder arthroplasty and, if left uncorrected, can result in superior glenoid tilt, which increases the risk of aseptic glenoid loosening. This study evaluates the impact of an E2 superior defect on reverse shoulder glenoid fixation in composite scapulae after correction of glenoid tilt by use of 2 different glenoid reaming techniques: eccentric reaming and off-axis reaming. A superior glenoid defect was created in 14 composite scapulae. The superior defect was corrected by 2 different glenoid reaming techniques: (1) eccentric reaming with implantation of a standard glenoid baseplate and (2) off-axis reaming with implantation of a superior-augment glenoid baseplate. Each corrected superior-defect scapula was then cyclically loaded (along with a control group consisting of 7 non-worn scapulae) for 10,000 cycles at 750 N; glenoid baseplate displacement was measured for each group to quantify fixation before and after cyclic loading. Regardless of the glenoid reaming technique or the glenoid baseplate type, each standard and superior-augment glenoid baseplate remained well fixed in this superior-defect model scenario after cyclic loading. No differences in baseplate displacement were observed either before or after cyclic loading between groups. Our results suggest that either glenoid reaming technique may be used to achieve fixation in the clinically challenging situation of superior wear with reverse shoulder arthroplasty. Basic science, biomechanical study. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  2. [Quantitative evaluation of fabricating complete denture by computer numerical control in manufacturing dentition and baseplate separately plus adhesive molding].

    PubMed

    Wang, H; Lv, P J; Wang, Y; Sun, Y C

    2016-10-18

    To quantitatively evaluate the assembly precision of fabricating complete denture by computer numerical control (CNC) in manufacturing dentition and baseplate separately plus adhesive molding. The 3D surface data of a standard edentulous maxilla plaster cast model and the temporary base-plate were obtained using an Activity 880 3D scanner. The data (data1) of a complete denture were designed using a set of computer aided design (CAD) software developed by the research group of this study. The pins without undercut were designed as 3D shape of the joining area of the dentition and the baseplate by using the software of Imageware 13.2 and Geomagic Studio 2013. Zero in the top and 0.05 mm in the rest surfaces of the retention pins were set for adhesive clearance. Zenotec T1 (5-axis milling machine) was employed to manufacture polymethyl methacrylate (PMMA) dentition and baseplate. Double sides posterior and one anterior "union teeth" were got. The teeth were inserted into the retention pins in the baseplate and cemented with self-curing resin (Huge Dental Material Co., Ltd). The denture was scanned with the 3D scanner to obtain dataset Data4. Data2 and Data3 registration was set in Data4, Data2 and Data3 were united to gain Data 5. The adhesive clearance on the top of the retentional pins was measured, which was originally designed into 0 mm, and the assembly precision of dentition and baseplate obtained. The average clearance measurements between the dentition and the baseplate: left molar teeth (0.44±0.04) mm, max 0.52 mm, min 0.29 mm; right molar teeth (0.52±0.07) mm, max 0.64 mm, min 0.28 mm; anterior teeth (0.60±0.10) mm, max 0.81 mm, min 0.40 mm; total average clearance (0.52±0.10) mm. The adhesive clearance can be controlled to the level of 0.5 mm when the joining part of the artificial teeth and the base was designed into the shape of retentional pins and the artificial dentition divided into 3 parts. We succeeded in using the CAD/ computer aided manufacturing (CAM) technology to fabricate the complete denture. Although the assembly precision of the dentition and the baseplate is not perfect, the results have proved that the technical routes are workable.

  3. Evaluation of the Benefits of High Temperature Electronics for Lunar Power Systems

    NASA Technical Reports Server (NTRS)

    Fay, Edgar H.

    1992-01-01

    A comparative evaluation is conducted of several approaches to the cooling of a lunar power system's power electronics, in view of the 400 K temperature of the 354-hour lunar day and lunar dust accumulation, which can contaminate power components and radiator surfaces. It is noted that, by raising the power electronics' baseplate temperature to 480 K, no thermal control system is required; the surface of the baseplate acts as its own, waste-heat-rejecting radiator, but the baseplate must be kept clean of lunar dust contamination.

  4. Solution and electron microscopy characterization of lactococcal phage baseplates expressed in Escherichia coli.

    PubMed

    Campanacci, Valérie; Veesler, David; Lichière, Julie; Blangy, Stéphanie; Sciara, Giuliano; Moineau, Sylvain; van Sinderen, Douwe; Bron, Patrick; Cambillau, Christian

    2010-10-01

    We report here the characterization of several large structural protein complexes forming the baseplates (or part of them) of Siphoviridae phages infecting Lactococcus lactis: TP901-1, Tuc2009 and p2. We revisited a "block cloning" expression strategy and extended this approach to genomic fragments encoding proteins whose interacting partners have not yet been clearly identified. Biophysical characterization of some of these complexes using circular dichroism and size exclusion chromatography, coupled with on-line light scattering and refractometry, demonstrated that the over-produced recombinant proteins interact with each other to form large (up to 1.9MDa) and stable baseplate assemblies. Some of these complexes were characterized by electron microscopy confirming their structural homogeneity as well as providing a picture of their overall molecular shapes and symmetry. Finally, using these results, we were able to highlight similarities and differences with the well characterized much larger baseplate of the myophage T4.

  5. Isolated resonator gyroscope with a drive and sense plate

    NASA Technical Reports Server (NTRS)

    Shcheglov, Kirill V. (Inventor); Challoner, A. Dorian (Inventor)

    2006-01-01

    The present invention discloses a resonator gyroscope comprising a vibrationally isolated resonator including a proof mass, a counterbalancing plate having an extensive planar region, and one or more flexures interconnecting the proof mass and counterbalancing plate. A baseplate is affixed to the resonator by the one or more flexures and sense and drive electrodes are affixed to the baseplate proximate to the extensive planar region of the counterbalancing plate for exciting the resonator and sensing movement of the gyroscope. The isolated resonator transfers substantially no net momentum to the baseplate when the resonator is excited.

  6. Structural and Functional Studies of gpX of Escherichia coli Phage P2 Reveal a Widespread Role for LysM Domains in the Baseplates of Contractile-Tailed Phages

    PubMed Central

    Fatehi Hassanabad, Mostafa; Chang, Tom; Pirani, Nawaz; Bona, Diane; Edwards, Aled M.

    2013-01-01

    A variety of bacterial pathogenicity determinants, including the type VI secretion system and the virulence cassettes from Photorhabdus and Serratia, share an evolutionary origin with contractile-tailed myophages. The well-characterized Escherichia coli phage P2 provides an excellent system for studies related to these systems, as its protein composition appears to represent the “minimal” myophage tail. In this study, we used nuclear magnetic resonance (NMR) spectroscopy to determine the solution structure of gpX, a 68-residue tail baseplate protein. Although the sequence and structure of gpX are similar to those of LysM domains, which are a large family associated with peptidoglycan binding, we did not detect a peptidoglycan-binding activity for gpX. However, bioinformatic analysis revealed that half of all myophages, including all that possess phage T4-like baseplates, encode a tail protein with a LysM-like domain, emphasizing a widespread role for this domain in baseplate function. While phage P2 gpX comprises only a single LysM domain, many myophages display LysM domain fusions with other tail proteins, such as the DNA circulation protein found in Mu-like phages and gp53 of T4-like phages. Electron microscopy of P2 phage particles with an incorporated gpX-maltose binding protein fusion revealed that gpX is located at the top of the baseplate, near the junction of the baseplate and tail tube. gpW, the orthologue of phage T4 gp25, was also found to localize to this region. A general colocalization of LysM-like domains and gpW homologues in diverse phages is supported by our bioinformatic analysis. PMID:24097944

  7. Glenoid morphology and the safe zone for protecting the suprascapular nerve during baseplate fixation in reverse shoulder arthroplasty.

    PubMed

    Yang, Yuhui; Zuo, Jianlin; Liu, Tong; Shao, Pu; Wu, Haihe; Gao, Zhongli; Xiao, Jianlin

    2018-03-01

    The purpose of this study was to investigate glenoid morphology and define the safe zone for protecting the suprascapular nerve baseplate screw during baseplate fixation in reverse shoulder arthroplasty (RSA) in a Chinese population. Shoulder computed tomography (CT) scans from 56 subjects were retrospectively reviewed. Three-dimensional (3D) reconstruction was performed using Mimics software, and corresponding bony references were used to evaluate glenoid morphology. To standardize evaluation, the coronal scapular plane was defined. Safe fixation distances and screw placements were investigated by constructing a simulated cutting plane of the baseplate during RSA. Mean glenoid height was 35.83 ± 2.95 mm, and width was 27.32 ± 2.78 mm, with significant sexual dimorphism (p < 0.01). According to the cutting plane morphology, the average baseplate radius was 13.84 ± 1.34 mm. The distances from the suprascapular notch and from two bony reference points at the base of the scapular spine to the cutting plane were 30.27 ± 2.77 mm, 18.39 ± 1.67 mm and 16.52 ± 1.52 mm, respectively, with a gender-related difference. Based on the clock face indication system, the danger zone caused by the suprascapular nerve projection was oriented between the two o'clock and eight o'clock positions in reference to the right shoulder. Glenoid size and the safe zone for screw fixation during RSA were characterized in a Chinese population. Careful consideration of baseplate fixation and avoidance of suprascapular nerve injury are important for improved clinical outcome.

  8. Bony increased-offset reversed shoulder arthroplasty: minimizing scapular impingement while maximizing glenoid fixation.

    PubMed

    Boileau, Pascal; Moineau, Grégory; Roussanne, Yannick; O'Shea, Kieran

    2011-09-01

    Scapular notching, prosthetic instability, limited shoulder rotation and loss of shoulder contour are associated with conventional medialized design reverse shoulder arthroplasty. Prosthetic (ie, metallic) lateralization increases torque at the baseplate-glenoid interface potentially leading to failure. We asked whether bony lateralization of reverse shoulder arthroplasty would avoid the problems caused by humeral medialization without increasing torque or shear force applied to the glenoid component. We prospectively followed 42 patients with rotator cuff deficiency treated with bony increased-offset reverse shoulder arthroplasty. A cylinder of autologous cancellous bone graft, harvested from the humeral head, was placed between the reamed glenoid surface and baseplate. Graft and baseplate fixation was achieved using a lengthened central peg (25 mm) and four screws. Patients underwent clinical, radiographic, and CT assessment at a minimum of 2 years after surgery. The humeral graft incorporated completely in 98% of cases (41 of 42) and partially in one. At a mean of 28 months postoperatively, no graft resorption, glenoid loosening, or postoperative instability was observed. Inferior scapular notching occurred in 19% (eight of 42). The absolute Constant-Murley score improved from 31 to 67. Thirty-six patients (86%) were able to internally rotate sufficiently to reach their back over the sacrum. Grafting of the glenoid surface during reverse shoulder arthroplasty effectively creates a long-necked scapula, providing the benefits of lateralization. Bony increased-offset reverse shoulder arthroplasty is associated with low rates of inferior scapular notching, improved shoulder rotation, no prosthetic instability and improved shoulder contour. In contrast to metallic lateralization, bony lateralization has the advantage of maintaining the prosthetic center of rotation at the prosthesis-bone interface, thus minimizing torque on the glenoid component. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  9. Disc resonator gyroscope fabrication process requiring no bonding alignment

    NASA Technical Reports Server (NTRS)

    Shcheglov, Kirill V. (Inventor)

    2010-01-01

    A method of fabricating a resonant vibratory sensor, such as a disc resonator gyro. A silicon baseplate wafer for a disc resonator gyro is provided with one or more locating marks. The disc resonator gyro is fabricated by bonding a blank resonator wafer, such as an SOI wafer, to the fabricated baseplate, and fabricating the resonator structure according to a pattern based at least in part upon the location of the at least one locating mark of the fabricated baseplate. MEMS-based processing is used for the fabrication processing. In some embodiments, the locating mark is visualized using optical and/or infrared viewing methods. A disc resonator gyroscope manufactured according to these methods is described.

  10. 75 FR 48623 - Airworthiness Directives; The Boeing Company Model 767-300 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-11

    ... fuselage skin and backup structure at the lower very high frequency (VHF) antenna cutout at station 1197... section 46 fuselage lower skin around the periphery of the VHF antenna baseplate at station 1197 + 99. We... antenna baseplate at station 1197 + 99. One operator reported 5 cracks, with a maximum length of 11 inches...

  11. Preheat effect on titanium plate fabricated by sputter-free selective laser melting in vacuum

    NASA Astrophysics Data System (ADS)

    Sato, Yuji; Tsukamoto, Masahiro; Shobu, Takahisa; Yamashita, Yorihiro; Yamagata, Shuto; Nishi, Takaya; Higashino, Ritsuko; Ohkubo, Tomomasa; Nakano, Hitoshi; Abe, Nobuyuki

    2018-04-01

    The dynamics of titanium (Ti) melted by laser irradiation was investigated in a synchrotron radiation experiment. As an indicator of wettability, the contact angle between a selective laser melting (SLM) baseplate and the molten Ti was measured by synchrotron X-rays at 30 keV during laser irradiation. As the baseplate temperature increased, the contact angle decreased, down to 28° at a baseplate temperature of 500 °C. Based on this result, the influence of wettability of a Ti plate fabricated by SLM in a vacuum was investigated. It was revealed that the improvement of wettability by preheating suppressed sputtering generation, and a surface having a small surface roughness was fabricated by SLM in a vacuum.

  12. Test and Evaluation of Ultrasonic Additive Manufacturing (UAM) for a Large Aircraft Maintenance Shelter (LAMS) Baseplate

    DTIC Science & Technology

    2015-03-26

    TEST AND EVALUATION OF ULTRASONIC ADDITIVE MANUFACTURING (UAM) FOR A LARGE AREA MAINTENANCE...States Government. AFIT-ENV-MS-15-M-158 TEST AND EVALUATION OF ULTRASONIC ADDITIVE MANUFACTURING FOR A LARGE AREA MAINTENANCE SHELTER...Civil Engineer (CE) operations. This research replicates a Large Area Maintenance Shelter (LAMS) baseplate design for ultrasonic additive

  13. Impact of Posterior Wear on Muscle Length with Reverse Shoulder Arthroplasty.

    PubMed

    Roche, Christopher P; Diep, Phong; Hamilton, Matthew A; Wright, Thomas W; Flurin, Pierre-Henri; Zuckerman, Joseph D; Routman, Howard D

    2015-12-01

    The use of reverse total shoulder arthroplasty (rTSA) in patients with posterior glenoid wear can be challenging. Implanting a baseplate in the correct version may require significant eccentric reaming, which further medializes the joint line and results in greater rotator cuff muscle shortening. To restore the joint line, bone graft may be required, though it is associated with additional risks. As an alternative solution, augmented glenoid baseplates offer the potential to restore the joint line and improve rotator cuff muscle tensioning without the need for eccentric reaming or supplemental bone graft. To that end, this computer analysis quantifies the rotator cuff muscle length for standard and augmented rTSA when used in a normal and posteriorly worn glenoid. These results demonstrate that shortening of the rotator cuff occurred for both the standard and posterior augmented reverse shoulder designs with additional muscle shortening occurring in scapula with posteriorly worn glenoids. More anatomic rotator cuff muscle tensioning was observed with augmented glenoid baseplates. The use of posterior augmented glenoid baseplates has the potential to improve stability and better restore active internal and external rotation, a current limitation of rTSA. However, clinical follow-up is necessary to confirm these favorable biomechanical results.

  14. [Plug-in Based Centralized Control System in Operating Rooms].

    PubMed

    Wang, Yunlong

    2017-05-30

    Centralized equipment controls in an operating room (OR) is crucial to an efficient workflow in the OR. To achieve centralized control, an integrative OR needs to focus on designing a control panel that can appropriately incorporate equipment from different manufactures with various connecting ports and controls. Here we propose to achieve equipment integration using plug-in modules. Each OR will be equipped with a dynamic plug-in control panel containing physically removable connecting ports. Matching outlets will be installed onto the control panels of each equipment used at any given time. This dynamic control panel will be backed with a database containing plug-in modules that can connect any two types of connecting ports common among medical equipment manufacturers. The correct connecting ports will be called using reflection dynamics. This database will be updated regularly to include new connecting ports on the market, making it easy to maintain, update, expand and remain relevant as new equipment are developed. Together, the physical panel and the database will achieve centralized equipment controls in the OR that can be easily adapted to any equipment in the OR.

  15. Quantifying the competing relationship between adduction range of motion and baseplate micromotion with lateralization of reverse total shoulder arthroplasty.

    PubMed

    Elwell, Josie; Choi, Joseph; Willing, Ryan

    2017-02-08

    Lateralizing the center of rotation (COR) of reverse total shoulder arthroplasty (rTSA) could improve functional outcomes and mitigate scapular notching, a commonly occurring complication of the procedure. However, resulting increases in torque at the bone-implant interface may negatively affect initial fixation of the glenoid-side component, especially if only two fixation screws can be placed. Shoulder-specific finite element (FE) models of four fresh-frozen cadaveric shoulders were constructed. Scapular geometry and material property distributions were derived from CT data. Generic baseplates with two and four fixation screws were virtually implanted, after which superiorly-oriented shear loads, accompanied by a compressive load, were applied incrementally further from the glenoid surface to simulate lateralization of the COR. Relationships between lateralization, adduction range of motion (ROM), the number of fixation screws and micromotion of the baseplate (initial implant fixation) were characterized. Lateralization significantly increases micromotion (p=0.015) and adduction ROM (p=0.001). Using two, versus four, baseplate fixation screws significantly increases micromotion (p=0.008). The effect of lateralization and the number of screws on adduction ROM and baseplate fixation is variable on a shoulder-specific basis. Trade-offs exist between functional outcomes, namely adduction ROM, and initial implant fixation and the negative effect of lateralization on implant fixation is amplified when only two fixation screws are used. The possibility of lateralizing the COR in order to improve functional outcomes of the procedure should be considered on a patient-specific basis accounting for factors such as availability and quality of bone stock. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Partial wetting gas-liquid segmented flow microreactor.

    PubMed

    Kazemi Oskooei, S Ali; Sinton, David

    2010-07-07

    A microfluidic reactor strategy for reducing plug-to-plug transport in gas-liquid segmented flow microfluidic reactors is presented. The segmented flow is generated in a wetting portion of the chip that transitions downstream to a partially wetting reaction channel that serves to disconnect the liquid plugs. The resulting residence time distributions show little dependence on channel length, and over 60% narrowing in residence time distribution as compared to an otherwise similar reactor. This partial wetting strategy mitigates a central limitation (plug-to-plug dispersion) while preserving the many attractive features of gas-liquid segmented flow reactors.

  17. Study of Plasma Behavior during ECRH Injection in the GAMMA 10 SMBI Experiments

    NASA Astrophysics Data System (ADS)

    Maidul Islam, Md.; Nakashima, Yousuke; Kobayashi, Shinji; Nishino, Nobuhiro; Ichimura, Kazuya; Iijima, Takaaki; Shahinul Islam, Md.; Yokodo, Takayuki; Lee, Guanyi; Yoshimoto, Tsubasa; Yamashita, Sotaro; Yoshikawa, Masayuki; Kohagura, Junko; Hirata, Mafumi; Minami, Ryutaro; Kariya, Tsuyoshi; Ikezoe, Ryuya; Ichimura, Makoto; Sakamoto, Mizuki; Imai, Tsuyoshi

    2018-01-01

    Establishment of fueling system is one of the critical issues for the future fusion reactors. Fueling experiment supersonic molecular beam injection (SMBI) have been carried out in the central-cell of GAMMA 10. In GAMMA 10, electron cyclotron resonance heating (ECRH) is used at plug/barrier-cells for the formation of the axial confining potential. Recently, ECRH was applied during SMBI to plug the loss particles and increased the plasma density in the central-cell compared to without ECRH. This result suggests that the particles are confined during SMBI due to the injection of ECRH at plug/barrier-cells in GAMMA 10.

  18. Design and fabrication of complete dentures using CAD/CAM technology

    PubMed Central

    Han, Weili; Li, Yanfeng; Zhang, Yue; lv, Yuan; Zhang, Ying; Hu, Ping; Liu, Huanyue; Ma, Zheng; Shen, Yi

    2017-01-01

    Abstract The aim of the study was to test the feasibility of using commercially available computer-aided design and computer-aided manufacturing (CAD/CAM) technology including 3Shape Dental System 2013 trial version, WIELAND V2.0.049 and WIELAND ZENOTEC T1 milling machine to design and fabricate complete dentures. The modeling process of full denture available in the trial version of 3Shape Dental System 2013 was used to design virtual complete dentures on the basis of 3-dimensional (3D) digital edentulous models generated from the physical models. The virtual complete dentures designed were exported to CAM software of WIELAND V2.0.049. A WIELAND ZENOTEC T1 milling machine controlled by the CAM software was used to fabricate physical dentitions and baseplates by milling acrylic resin composite plates. The physical dentitions were bonded to the corresponding baseplates to form the maxillary and mandibular complete dentures. Virtual complete dentures were successfully designed using the software through several steps including generation of 3D digital edentulous models, model analysis, arrangement of artificial teeth, trimming relief area, and occlusal adjustment. Physical dentitions and baseplates were successfully fabricated according to the designed virtual complete dentures using milling machine controlled by a CAM software. Bonding physical dentitions to the corresponding baseplates generated the final physical complete dentures. Our study demonstrated that complete dentures could be successfully designed and fabricated by using CAD/CAM. PMID:28072686

  19. Outcomes of reverse shoulder arthroplasty using a mini 25-mm glenoid baseplate.

    PubMed

    Athwal, George S; Faber, Kenneth J

    2016-01-01

    As worldwide use of reverse shoulder arthroplasty (RSA) increases, a range of implant sizes may be required to match regional and ethnic variation in patients' height and bone size. The purpose of this study was to report the outcomes of RSA using a mini 25-mm-diameter glenoid baseplate in smaller patients with rotator cuff arthropathy. Between 2009 and 2012, 28 patients underwent RSA for cuff-tear arthropathy using a 25-mm circular glenoid baseplate (Aequlais Reversed, Tornier, Bloomington, MN, USA). Twenty-four patients were able to return for comprehensive follow-up. The mean height of the entire cohort was 158 ± 10 cm (5 ft. 2 in.). The indication to use a smaller baseplate was a combination of preoperative templating using computed tomography (CT) and intraoperative measurements of glenoid width. At a mean of 36 ± 8 months' follow-up, there were no revisions or glenoid-sided failures. The mean American Shoulder and Elbow Surgeons (ASES) score was 70 ± 10, the Simple Shoulder Test (SST) was 10 ± 2, the Constant was 60 ± 10 and the Disabilities of the Arm, Shoulder and Hand (DASH) was 18 ± 15. Mean active forward elevation was 140 ± 15°, active external rotation was 21 ± 15° and active internal rotation was to the sacroiliac joint. Mean shoulder strength in flexion was 5.2 ± 1.7 kg, in external rotation was 2.9 ± 1.4 kg and in internal rotation was 4.3 ± 1.2 kg. Radiographs demonstrated no evidence of glenoid loosening. There was, however, a 62 % rate of scapular notching. Short-term outcomes of mini 25-mm baseplate RSA in proportionally smaller patients are good and demonstrate implant safety and effectiveness. Scapular notching rates are worrisome, and additional follow-up is necessary to determine if notching is progressive and becomes symptomatic.

  20. Unbalanced-flow, fluid-mixing plug with metering capabilities

    NASA Technical Reports Server (NTRS)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Van Buskirk, Paul D. (Inventor)

    2009-01-01

    A fluid mixer plug has holes formed therethrough such that a remaining portion is closed to fluid flow. The plug's inlet face defines a central circuit region and a ring-shaped region with the ring-shaped region including at least some of the plug's remaining portion so-closed to fluid flow. This remaining portion or closed region at each radius R of the ring shaped region satisfies a radius independent, flow-based relationship. Entry openings are defined in the plug's inlet face in correspondence with the holes. The entry openings define an open flow area at each radius of the ring-shaped region. The open flow area at each such radius satisfies the inverse of the flow-based relationship defining the closed regions of the plug.

  1. Plug-and-play initiative : phase II : final report.

    DOT National Transportation Integrated Search

    2017-01-01

    Clear Roads has undertaken an initiative to establish a Plug-and-Play protocol that fosters interoperability between various winter maintenance equipment and a point location (central office). This report documents the data types and communication me...

  2. Crystallization and preliminary X-ray analysis of gene product 44 from bacteriophage Mu

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kondou, Youhei; Faculty of Pharmaceutical Sciences, Toyama Medical and Pharmaceutical University, Toyama; Kitazawa, Daisuke

    2005-01-01

    Bacteriophage Mu baseplate protein gene product 44 was crystallized. The crystal belongs to space group R3, with unit-cell parameters a = b = 126.6, c = 64.2 Å. Bacteriophage Mu baseplate protein gene product 44 (gp44) is an essential protein required for the assembly of viable phages. To investigate the roles of gp44 in baseplate assembly and infection, gp44 was crystallized at pH 6.0 in the presence of 20% 2-methyl-2,4-pentanediol. The crystals belong to space group R3, with unit-cell parameters a = b = 127.47, c = 63.97 Å. The crystals diffract X-rays to at least 2.1 Å resolution andmore » are stable in the X-ray beam and are therefore appropriate for structure determination. Native data have been collected to 2.1 Å resolution using a DIP6040 image-plate system at beamline BL44XU at the SPring-8 facility in Japan.« less

  3. Optimizing glenosphere position and fixation in reverse shoulder arthroplasty, Part One: The twelve-mm rule.

    PubMed

    Kelly, James D; Humphrey, C Scott; Norris, Tom R

    2008-01-01

    The Aequalis Reversed Shoulder Prosthesis (Tornier, Inc., Edina, MN) is a successful treatment option for older, low-demand patients with rotator cuff arthropathy. Scapular notching is the most common radiographic complication and is associated with poorer intermediate-term clinical outcomes. Aligning the lower border of the glenosphere baseplate with the inferior glenoid rim has been recommended to reduce this complication, but guidelines for achieving this positioning are currently lacking. The purpose of this study is to develop a rule of thumb that will facilitate proper glenosphere component positioning intraoperatively. Utilizing a computed tomography-templating protocol, we found that the ideal location of the drill hole for the baseplate post was 11.5 +/- 1.0 mm above the inferior glenoid rim. On the basis of measurements from 10 implanted cadaveric specimens, we concluded that drilling the baseplate posthole 12 mm above the inferior glenoid rim-the 12-mm rule-will result in excellent glenosphere position in most cases.

  4. Integral resonator gyroscope

    NASA Technical Reports Server (NTRS)

    Shcheglov, Kirill V. (Inventor); Challoner, A. Dorian (Inventor); Hayworth, Ken J. (Inventor); Wiberg, Dean V. (Inventor); Yee, Karl Y. (Inventor)

    2008-01-01

    The present invention discloses an inertial sensor having an integral resonator. A typical sensor comprises a planar mechanical resonator for sensing motion of the inertial sensor and a case for housing the resonator. The resonator and a wall of the case are defined through an etching process. A typical method of producing the resonator includes etching a baseplate, bonding a wafer to the etched baseplate, through etching the wafer to form a planar mechanical resonator and the wall of the case and bonding an end cap wafer to the wall to complete the case.

  5. Method of producing an integral resonator sensor and case

    NASA Technical Reports Server (NTRS)

    Challoner, A. Dorian (Inventor); Yee, Karl Y. (Inventor); Shcheglov, Kirill V. (Inventor); Hayworth, Ken J. (Inventor); Wiberg, Dean V. (Inventor)

    2005-01-01

    The present invention discloses an inertial sensor having an integral resonator. A typical sensor comprises a planar mechanical resonator for sensing motion of the inertial sensor and a case for housing the resonator. The resonator and a wall of the case are defined through an etching process. A typical method of producing the resonator includes etching a baseplate, bonding a wafer to the etched baseplate, through etching the wafer to form a planar mechanical resonator and the wall of the case and bonding an end cap wafer to the wall to complete the case.

  6. Pulse-actuated fuel-injection spark plug

    DOEpatents

    Murray, Ian; Tatro, Clement A.

    1978-01-01

    A replacement spark plug for reciprocating internal combustion engines that functions as a fuel injector and as a spark plug to provide a "stratified-charge" effect. The conventional carburetor is retained to supply the main fuel-air mixture which may be very lean because of the stratified charge. The replacement plug includes a cylindrical piezoelectric ceramic which contracts to act as a pump whenever an ignition pulse is applied to a central rod through the ceramic. The rod is hollow at its upper end for receiving fuel, it is tapered along its lower length to act as a pump, and it is flattened at its lower end to act as a valve for fuel injection from the pump into the cylinder. The rod also acts as the center electrode of the plug, with the spark jumping from the plug base to the lower end of the rod to thereby provide spark ignition that has inherent proper timing with the fuel injection.

  7. Accuracy of patient-specific guided glenoid baseplate positioning for reverse shoulder arthroplasty.

    PubMed

    Levy, Jonathan C; Everding, Nathan G; Frankle, Mark A; Keppler, Louis J

    2014-10-01

    The accuracy of reproducing a surgical plan during shoulder arthroplasty is improved by computer assistance. Intraoperative navigation, however, is challenged by increased surgical time and additional technically difficult steps. Patient-matched instrumentation has the potential to reproduce a similar degree of accuracy without the need for additional surgical steps. The purpose of this study was to examine the accuracy of patient-specific planning and a patient-specific drill guide for glenoid baseplate placement in reverse shoulder arthroplasty. A patient-specific glenoid baseplate drill guide for reverse shoulder arthroplasty was produced for 14 cadaveric shoulders based on a plan developed by a virtual preoperative 3-dimensional planning system using thin-cut computed tomography images. Using this patient-specific guide, high-volume shoulder surgeons exposed the glenoid through a deltopectoral approach and drilled the bicortical pathway defined by the guide. The trajectory of the drill path was compared with the virtual preoperative planned position using similar thin-cut computed tomography images to define accuracy. The drill pathway defined by the patient-matched guide was found to be highly accurate when compared with the preoperative surgical plan. The translational accuracy was 1.2 ± 0.7 mm. The accuracy of inferior tilt was 1.2° ± 1.2°. The accuracy of glenoid version was 2.6° ± 1.7°. The use of patient-specific glenoid baseplate guides is highly accurate in reproducing a virtual 3-dimensional preoperative plan. This technique delivers the accuracy observed using computerized navigation without any additional surgical steps or technical challenges. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. Nickel hydrogen cell tests. [recharging

    NASA Technical Reports Server (NTRS)

    Mueller, V. C.

    1981-01-01

    Some parametric tests followed by cycling tests are described for the characterization of the service life of nickel hydrogen cells. Three cells were automatically cycled in simulated low Earth orbit in 35 minute discharge, 55 minute charge, with charging voltage limited, temperature compensated. The cells were mounted in a fixture that conducts heat to an aluminum baseplate. The baseplate in turn, is bounded in a temperature controlled bath to remove the heat from the mounted fixture. One cell was tested with a zircar separator, which failed after 2473 cyles. Two other cells were tested one with a zircar separator; the other with asbestos. More than 400 cycles were achieved.

  9. Regenerative Endodontic Treatment versus Apical Plug in Immature Teeth: Three-Year Follow-Up.

    PubMed

    Asgary, Saeed; Fazlyab, Mahta; Nosrat, Ali

    This report compares and evaluates the treatment outcomes of regenerative endodontic treatment and apical plug as two accepted treatment protocols in a pair of necrotic immature maxillary central incisors of a 12-year old female. The patient was referred complaining of a dull pain and swelling in her upper lip area. She had a history of trauma to the anterior maxilla two years earlier. Both teeth were clinically diagnosed with pulp necrosis and periapical radiographs revealed that separate periapical radiolucent lesions surrounded the immature apices of both teeth. The left and right incisors were treated with apical plug and regenerative endodontic treatment, respectively, using calcium-enriched mixture (CEM) cement. The patient was followed-up for three years. During this period, both teeth were clinically asymptomatic and showed complete radiographic healing of the periapical lesions. The right central incisor showed root development. No tooth discoloration was evident. Apexification by apical plug placement and pulp regeneration are both reliable treatments for immature non-vital teeth. In order to choose the right treatment the advantages of either technique should be weighed against its drawbacks. CEM cement can be successfully applied for both purposes. This biomaterial causes less discoloration of the tooth.

  10. Portal vein embolization with plug/coils improves hepatectomy outcome.

    PubMed

    Malinowski, Maciej; Geisel, Dominik; Stary, Victoria; Denecke, Timm; Seehofer, Daniel; Jara, Maximillian; Baron, Annekathrin; Pratschke, Johann; Gebauer, Bernhard; Stockmann, Martin

    2015-03-01

    Portal vein embolization (PVE) has become the standard of care before extended hepatectomy. Various PVE methods using different embolization materials have been described. In this study, we compared PVE with polyvinyl alcohol particles alone (PVA only) versus PVA with plug or coils (PVA + plug/coils). Patients undergoing PVE before hepatectomy were included. PVA alone was used until December 2013, thereafter plug or coils were placed in addition. The volume of left lateral liver lobe (LLL), clinical parameters, and liver function tests were measured before PVE and resection. A total of 43 patients were recruited into the PVA only group and 42 were recruited into the PVA + plug/coils group. There were no major differences between groups except significantly higher total bilirubin level before PVE in the PVA only group, which improved before hepatectomy. Mean LLL volume increased by 25.7% after PVE in the PVA only group and by 44% in the PVA + plug/coils group (P < 0.001). Recanalization was significantly less common in the PVA + plug/coils group. In multivariate regression, initial LLL volume and use of plug or coils were the only parameters influencing LLL volume increase. The postoperative liver failure rate was significantly reduced in PVA + plug/coils group (P = <0.001). PVE using PVA particles together with plug or coils is a safe and efficient method to increase future liver remnant volume. The additional central embolization with plug or coils led to an increased hypertrophy, due to lower recanalization rates, and subsequently decreased incidence of postoperative liver failure. No additional procedure-specific complications were observed in this series. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Nanoscale stiffness topography reveals structure and mechanics of the transport barrier in intact nuclear pore complexes.

    PubMed

    Bestembayeva, Aizhan; Kramer, Armin; Labokha, Aksana A; Osmanović, Dino; Liashkovich, Ivan; Orlova, Elena V; Ford, Ian J; Charras, Guillaume; Fassati, Ariberto; Hoogenboom, Bart W

    2015-01-01

    The nuclear pore complex (NPC) is the gate for transport between the cell nucleus and the cytoplasm. Small molecules cross the NPC by passive diffusion, but molecules larger than ∼5 nm must bind to nuclear transport receptors to overcome a selective barrier within the NPC. Although the structure and shape of the cytoplasmic ring of the NPC are relatively well characterized, the selective barrier is situated deep within the central channel of the NPC and depends critically on unstructured nuclear pore proteins, and is therefore not well understood. Here, we show that stiffness topography with sharp atomic force microscopy tips can generate nanoscale cross-sections of the NPC. The cross-sections reveal two distinct structures, a cytoplasmic ring and a central plug structure, which are consistent with the three-dimensional NPC structure derived from electron microscopy. The central plug persists after reactivation of the transport cycle and resultant cargo release, indicating that the plug is an intrinsic part of the NPC barrier. Added nuclear transport receptors accumulate on the intact transport barrier and lead to a homogenization of the barrier stiffness. The observed nanomechanical properties in the NPC indicate the presence of a cohesive barrier to transport and are quantitatively consistent with the presence of a central condensate of nuclear pore proteins in the NPC channel.

  12. Nanoscale stiffness topography reveals structure and mechanics of the transport barrier in intact nuclear pore complexes

    PubMed Central

    Labokha, Aksana A.; Osmanović, Dino; Liashkovich, Ivan; Orlova, Elena V.; Ford, Ian J.; Charras, Guillaume; Fassati, Ariberto; Hoogenboom, Bart W.

    2014-01-01

    The nuclear pore complex (NPC) is the gate for transport between the cell nucleus and the cytoplasm. Small molecules cross the NPC by passive diffusion, but molecules larger than ~5 nm must bind to nuclear transport receptors to overcome a selective barrier within the NPC1. Whilst the structure and shape of the cytoplasmic ring of the NPC are relatively well characterized2-5, the selective barrier is situated deep within the central channel of the NPC and depends critically on unstructured nuclear pore proteins5,6, and is therefore not well understood. Here, we show that stiffness topography7 with sharp atomic force microscopy tips can generate nanoscale cross sections of the NPC. The cross sections reveal two distinct structures, a cytoplasmic ring and a central plug structure, which are consistent with the three-dimensional NPC structure derived from electron microscopy2-5. The central plug persists after reactivation of the transport cycle and resultant cargo release, indicating that the plug is an intrinsic part of the NPC barrier. Added nuclear transport receptors accumulate on the intact transport barrier and lead to a homogenization of the barrier stiffness. The observed nanomechanical properties in the NPC indicate the presence of a cohesive barrier to transport, and are quantitatively consistent with the presence of a central condensate of nuclear pore proteins in the NPC channel. PMID:25420031

  13. Nanoscale stiffness topography reveals structure and mechanics of the transport barrier in intact nuclear pore complexes

    NASA Astrophysics Data System (ADS)

    Bestembayeva, Aizhan; Kramer, Armin; Labokha, Aksana A.; Osmanović, Dino; Liashkovich, Ivan; Orlova, Elena V.; Ford, Ian J.; Charras, Guillaume; Fassati, Ariberto; Hoogenboom, Bart W.

    2015-01-01

    The nuclear pore complex (NPC) is the gate for transport between the cell nucleus and the cytoplasm. Small molecules cross the NPC by passive diffusion, but molecules larger than ∼5 nm must bind to nuclear transport receptors to overcome a selective barrier within the NPC. Although the structure and shape of the cytoplasmic ring of the NPC are relatively well characterized, the selective barrier is situated deep within the central channel of the NPC and depends critically on unstructured nuclear pore proteins, and is therefore not well understood. Here, we show that stiffness topography with sharp atomic force microscopy tips can generate nanoscale cross-sections of the NPC. The cross-sections reveal two distinct structures, a cytoplasmic ring and a central plug structure, which are consistent with the three-dimensional NPC structure derived from electron microscopy. The central plug persists after reactivation of the transport cycle and resultant cargo release, indicating that the plug is an intrinsic part of the NPC barrier. Added nuclear transport receptors accumulate on the intact transport barrier and lead to a homogenization of the barrier stiffness. The observed nanomechanical properties in the NPC indicate the presence of a cohesive barrier to transport and are quantitatively consistent with the presence of a central condensate of nuclear pore proteins in the NPC channel.

  14. Cryogenic insulation strength and bond tester

    NASA Technical Reports Server (NTRS)

    Schuerer, P. H.; Ehl, J. H.; Prasthofer, W. P. (Inventor)

    1985-01-01

    A method and apparatus for testing the tensile strength and bonding strength of sprayed-on foam insulation attached to metal cryogenic fuel tanks is described. A circular cutter is used to cut the insulation down to the surface of the metal tank to form plugs of the insulation for testing in situ on the tank. The apparatus comprises an electromechanical pulling device powered by a belt battery pack. The pulling device comprises a motor driving a mechanical pulling structure comprising a horizontal shaft connected to two bell cracks which are connected to a central member. When the lower end of member is attached to a fitting, which in turn is bonded to a plug, a pulling force is exerted on the plug sufficient to rupture it. The force necessary to rupture the plug or pull it loose is displayed as a digital read-out.

  15. Visualizing the Central Limit Theorem through Simulation

    ERIC Educational Resources Information Center

    Ruggieri, Eric

    2016-01-01

    The Central Limit Theorem is one of the most important concepts taught in an introductory statistics course, however, it may be the least understood by students. Sure, students can plug numbers into a formula and solve problems, but conceptually, do they really understand what the Central Limit Theorem is saying? This paper describes a simulation…

  16. TssA forms a gp6-like ring attached to the type VI secretion sheath.

    PubMed

    Planamente, Sara; Salih, Osman; Manoli, Eleni; Albesa-Jové, David; Freemont, Paul S; Filloux, Alain

    2016-08-01

    The type VI secretion system (T6SS) is a supra-molecular bacterial complex that resembles phage tails. It is a killing machine which fires toxins into target cells upon contraction of its TssBC sheath. Here, we show that TssA1 is a T6SS component forming dodecameric ring structures whose dimensions match those of the TssBC sheath and which can accommodate the inner Hcp tube. The TssA1 ring complex binds the T6SS sheath and impacts its behaviour in vivo In the phage, the first disc of the gp18 sheath sits on a baseplate wherein gp6 is a dodecameric ring. We found remarkable sequence and structural similarities between TssA1 and gp6 C-termini, and propose that TssA1 could be a baseplate component of the T6SS Furthermore, we identified similarities between TssK1 and gp8, the former interacting with TssA1 while the latter is found in the outer radius of the gp6 ring. These observations, combined with similarities between TssF and gp6N-terminus or TssG and gp53, lead us to propose a comparative model between the phage baseplate and the T6SS. © 2016 The Authors. Published under the terms of the CC BY 4.0 license.

  17. Effects of canal plugging on the vestibuloocular reflex and vestibular nerve discharge during passive and active head rotations.

    PubMed

    Sadeghi, Soroush G; Goldberg, Jay M; Minor, Lloyd B; Cullen, Kathleen E

    2009-11-01

    Mechanical occlusion (plugging) of the slender ducts of semicircular canals has been used in the clinic as well as in basic vestibular research. Here, we investigated the effect of canal plugging in two macaque monkeys on the horizontal vestibuloocular reflex (VOR) and the responses of vestibular-nerve afferents during passive head rotations. Afferent responses to active head movements were also studied. The horizontal VOR gain decreased after plugging to <0.1 for frequencies <2 Hz but rose to about 0.6 as frequency was increased to 15 Hz. Afferents innervating plugged horizontal canals had response sensitivities that increased with the frequency of passive rotations from <0.01 (spikes/s)/( degrees/s) at 0.5 Hz to values of about 0.2 and 0.5 (spikes/s)/( degrees/s) at 8 Hz for regular and irregular afferents, respectively (<50% of responses in controls). An increase in phase lead was also noted following plugging in afferent discharge, but not in the VOR. Because the phase discrepancy between the VOR and afferent discharge is much larger than that seen in control animals, this suggests that central adaptation shapes VOR dynamics following plugging. The effect of canal plugging on afferent responses can be modeled as an increase in stiffness and a reduction in the dominant time constant and gain in the transfer function describing canal dynamics. Responses were also evident during active head rotations, consistent with the frequency content of these movements. We conclude that canal plugging in macaques is effective only at frequencies <2 Hz. At higher frequencies, afferents show significant responses, with a nearly 90 degrees phase lead, such that they encode near-rotational acceleration. Our results demonstrate that afferents innervating plugged canals respond robustly during voluntary movements, a finding that has implications for understanding the effects of canal plugging in clinical practice.

  18. Effects of Canal Plugging on the Vestibuloocular Reflex and Vestibular Nerve Discharge During Passive and Active Head Rotations

    PubMed Central

    Sadeghi, Soroush G.; Goldberg, Jay M.; Minor, Lloyd B.

    2009-01-01

    Mechanical occlusion (plugging) of the slender ducts of semicircular canals has been used in the clinic as well as in basic vestibular research. Here, we investigated the effect of canal plugging in two macaque monkeys on the horizontal vestibuloocular reflex (VOR) and the responses of vestibular-nerve afferents during passive head rotations. Afferent responses to active head movements were also studied. The horizontal VOR gain decreased after plugging to <0.1 for frequencies <2 Hz but rose to about 0.6 as frequency was increased to 15 Hz. Afferents innervating plugged horizontal canals had response sensitivities that increased with the frequency of passive rotations from <0.01 (spikes/s)/(°/s) at 0.5 Hz to values of about 0.2 and 0.5 (spikes/s)/(°/s) at 8 Hz for regular and irregular afferents, respectively (<50% of responses in controls). An increase in phase lead was also noted following plugging in afferent discharge, but not in the VOR. Because the phase discrepancy between the VOR and afferent discharge is much larger than that seen in control animals, this suggests that central adaptation shapes VOR dynamics following plugging. The effect of canal plugging on afferent responses can be modeled as an increase in stiffness and a reduction in the dominant time constant and gain in the transfer function describing canal dynamics. Responses were also evident during active head rotations, consistent with the frequency content of these movements. We conclude that canal plugging in macaques is effective only at frequencies <2 Hz. At higher frequencies, afferents show significant responses, with a nearly 90° phase lead, such that they encode near-rotational acceleration. Our results demonstrate that afferents innervating plugged canals respond robustly during voluntary movements, a finding that has implications for understanding the effects of canal plugging in clinical practice. PMID:19726724

  19. Molecular basis of the copulatory plug polymorphism in C. elegans

    PubMed Central

    Palopoli, Michael F.; Rockman, Matthew V.; TinMaung, Aye; Ramsay, Camden; Curwen, Stephen; Aduna, Andrea; Laurita, Jason; Kruglyak, Leonid

    2008-01-01

    Heritable variation is the raw material for evolutionary change, and understanding its genetic basis is one of the central problems in modern biology. We investigated the genetic basis of a classic phenotypic dimorphism in the nematode Caenorhabditis elegans. Males from many natural isolates deposit a copulatory plug after mating, whereas males from other natural isolates—including the standard wild-type strain (N2 Bristol) that is used in most research laboratories—do not deposit plugs1. The copulatory plug is a gelatinous mass that covers the hermaphrodite vulva, and its deposition decreases the mating success of subsequent males2. We show that the plugging polymorphism results from the insertion of a retrotransposon into an exon of a novel mucin-like gene, plg-1, whose product is a major structural component of the copulatory plug. The gene is expressed in a subset of secretory cells of the male somatic gonad, and its loss has no evident effects beyond the loss of male mate-guarding. Although C. elegans descends from an obligate-outcrossing, male-female ancestor3, 4, it occurs primarily as self-fertilizing hermaphrodites5–7. The reduced selection on male-male competition associated with the origin of hermaphroditism may have permitted the global spread of a loss-of-function mutation with restricted pleiotropy. PMID:18633349

  20. Treatment of horizontal root fractures using MTA as apical plug: report of 3 cases.

    PubMed

    Kusgoz, Adem; Yildirim, Tahsin; Tanriver, Mehmet; Yesilyurt, Cemal

    2009-05-01

    Root fractures are rare occurrences through all dental injuries. They comprise only 0.5% to 7.0% of traumas affecting the permanent teeth. Generally the cervical and middle thirds of the roots are affected. The healing of these lesions depends on the health of the pulp, dentine, cementum, and alveolar bone. These case reports describe the management and 2-year follow-up of 3 maxillary central incisors with horizontal root fractures treated with mineral trioxide aggregate (MTA) as apical plug.

  1. Crystallization and preliminary X-ray analysis of gene product 44 from bacteriophage Mu

    PubMed Central

    Kondou, Youhei; Kitazawa, Daisuke; Takeda, Shigeki; Yamashita, Eiki; Mizuguchi, Mineyuki; Kawano, Keiichi; Tsukihara, Tomitake

    2005-01-01

    Bacteriophage Mu baseplate protein gene product 44 (gp44) is an essential protein required for the assembly of viable phages. To investigate the roles of gp44 in baseplate assembly and infection, gp44 was crystallized at pH 6.0 in the presence of 20% 2-methyl-2,4-pentanediol. The crystals belong to space group R3, with unit-cell parameters a = b = 127.47, c = 63.97 Å. The crystals diffract X-­rays to at least 2.1 Å resolution and are stable in the X-ray beam and are therefore appropriate for structure determination. Native data have been collected to 2.1 Å resolution using a DIP6040 image-plate system at beamline BL44XU at the SPring-8 facility in Japan. PMID:16508104

  2. Initial mechanical stability of cementless highly-porous titanium tibial components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stone, Timothy Brandon; Amer, Luke D; Warren, Christopher P

    Cementless fixation in total knee replacement has seen limited use since reports of early failure surfaced in the late 80s and early 90s. However the emergence of improved biomaterials, particularly porous titanium and tantalum, has led to a renewed interest in developing a cementless tibial component to enhance long-term survivorship of the implants. Cement is commonly employed to minimize micromotion in new implants but represents a weak interface between the implant and bone. The elimination of cement and application of these new biomaterials, which theoretically provide improved stability and ultimate osseointegration, would likely result in greater knee replacement success. Additionally,more » the removal of cement from the procedure would help minimize surgical durations and get rid of the time needed for curing, thereby the chance of infection. The purpose of this biomechanical study was twofold. The first goal was to assess whether vibration analysis techniques can be used to evaluate and characterize initial mechanical stability of cementless implants more accurately than the traditional method of micromotion determination, which employs linear variable differential transducers (LVDTs). Second, an evaluative study was performed to determine the comparative mechanical stability of five designs of cementless tibial components under mechanical loading designed to simulate in vivo forces. The test groups will include a cemented Triathlon Keeled baseplate control group, three different 2-peg cementless baseplates with smooth, mid, and high roughnesses and a 4-peg cement/ess baseplate with mid-roughness.« less

  3. Aneurysm of an Anomalous Systemic Artery Supplying the Normal Basal Segments of the Left Lower Lobe: Endovascular Treatment with the Amplatzer Vascular Plug II and Coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Canyigit, Murat, E-mail: mcanyigit@yahoo.com; Gumus, Mehmet; Kilic, Evrim

    2011-02-15

    An anomalous systemic artery originating from the descending thoracic aorta supplying the normal basal segments of the lower lobe of the left lung without sequestration is a rare congenital anomaly. The published surgical treatments include lobectomy, segmentectomy, anastomosis, and ligation. In addition, endovascular treatment with coils has been reported. A second-generation occluder, the Amplatzer Vascular Plug II (AVP II), has a central plug and two occlusion disks and a finer, more densely woven nitinol wire, thus enabling faster embolization. This published case is the first successful occlusion of an aneurysm of an anomalous systemic artery with the AVP II andmore » fibered coils, with 10 months of follow-up.« less

  4. Knife-edge seal for vacuum bagging

    NASA Technical Reports Server (NTRS)

    Rauschl, J. A.

    1980-01-01

    Cam actuated clamps pinch bagging material between long knife edge (mounted to clamps) and high temperature rubber cushion bonded to baseplate. No adhesive, tape, or sealing groove is needed to seal edge of bagging sheet against base plate.

  5. Power module assemblies with staggered coolant channels

    DOEpatents

    Herron, Nicholas Hayden; Mann, Brooks S; Korich, Mark D

    2013-07-16

    A manifold is provided for supporting a power module assembly with a plurality of power modules. The manifold includes a first manifold section. The first face of the first manifold section is configured to receive the first power module, and the second face of the first manifold section defines a first cavity with a first baseplate thermally coupled to the first power module. The first face of the second manifold section is configured to receive the second power module, and the second face of the second manifold section defines a second cavity with a second baseplate thermally coupled to the second power module. The second face of the first manifold section and the second face of the second manifold section are coupled together such that the first cavity and the second cavity form a coolant channel. The first cavity is at least partially staggered with respect to second cavity.

  6. Reverse total shoulder arthroplasty

    PubMed Central

    Familiari, Filippo; Rojas, Jorge; Nedim Doral, Mahmut; Huri, Gazi; McFarland, Edward G.

    2018-01-01

    Since the introduction of reverse total shoulder arthroplasty (RTSA) in 1987 (in Europe) and 2004 (in the United States), the number of RTSAs performed annually has increased. Although the main indication for RTSA has been rotator cuff tears, indications have expanded to include several shoulder conditions, many of which involve dysfunction of the rotator cuff. RTSA complications have been reported to affect 19% to 68% of patients and include acromial fracture, haematoma, infection, instability, mechanical baseplate failure, neurological injury, periprosthetic fracture and scapular notching. Current controversies in RTSA include optimal baseplate positioning, humeral neck-shaft angle (135° versus 155°), glenosphere placement (medial, lateral or bony increased offset RTSA) and subscapularis repair. Improvements in prosthesis design, surgeon experience and clinical results will need to occur to optimize this treatment for many shoulder conditions. Cite this article: EFORT Open Rev 2018;3:58–69 DOI: 10.1302/2058-5241.3.170044 PMID:29657846

  7. Orthograde retreatment failure with extruded MTA apical plug in a large periradicular lesion followed by surgical intervention: case report.

    PubMed

    Brito-Junior, Manoel; Faria-e-Silva, Andre Luis; Quintino, Alex Carvalho; Moreira-Junior, Gil; Geber, Mauro; Camilo, Carla Cristina; Soares, Janir Alves

    2012-01-01

    Absence of periapical healing after orthograde retreatment using an apical plug with mineral trioxide aggregate (MTA) can require surgical intervention. A patient with a root-filled maxillary central incisor with chronic apical periodontitis and sinus tract was referred for endodontic retreatment. Excessive apical enlargement was verified, indicating an MTA apical plug placement; however, an unintentional extrusion of MTA occurred during this step. The root canal was filled with gutta-percha and sealer, and periodic recalls were scheduled. The sinus tract was observed after six months and the lesion remained unaltered, although the extruded MTA had resorbed; therefore, an apicoectomy and retrograde root-end filling with MTA were performed. Absence of sinus tract, normal clinical aspect, and complete repair of the lesion were observed at the two-year follow-up.

  8. Punctal occlusion for dry eye syndrome.

    PubMed

    Ervin, Ann-Margret; Law, Andrew; Pucker, Andrew D

    2017-06-26

    Dry eye syndrome is a disorder of the tear film that is associated with symptoms of ocular discomfort. Punctal occlusion is a mechanical treatment that blocks the tear drainage system in order to aid in the preservation of natural tears on the ocular surface. To assess the effects of punctal plugs versus no punctal plugs, different types of punctal plugs, and other interventions for managing dry eye. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 11), MEDLINE Ovid (1946 to 8 December 2016), Embase.com (1947 to 8 December 2016), PubMed (1948 to 8 December 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 8 December 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com; last searched 18 November 2012 - this resource is now archived), ClinicalTrials.gov (www.clinicaltrials.gov; searched 8 December 2016), and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en; searched 8 December 2016). We did not use any date or language restrictions in the electronic searches for trials. We also searched the Science Citation Index-Expanded database and reference lists of included studies. The evidence was last updated on 8 December 2016 SELECTION CRITERIA: We included randomized and quasi-randomized controlled trials of collagen or silicone punctal plugs in symptomatic participants diagnosed with aqueous tear deficiency or dry eye syndrome. Two review authors independently assessed trial quality and extracted data. We contacted study investigators for additional information when needed. We included 18 trials (711 participants, 1249 eyes) from Austria, Canada, China, Greece, Japan, Mexico, Netherlands, Turkey, the UK, and the USA in this review. We also identified one ongoing trial. Overall we judged these trials to be at unclear risk of bias because they were poorly reported. We assessed the evidence for eight comparisons.Five trials compared punctal plugs with no punctal plugs (control). Three of these trials employed a sham treatment and two trials observed the control group. Two trials did not report outcome data relevant to this review. There was very low-certainty evidence on symptomatic improvement. The three trials that reported this outcome used different scales to measure symptoms. In all three trials, there was little or no improvement in symptom scores with punctal plugs compared with no punctal plugs. Low-certainty evidence from one trial suggested less ocular surface staining in the punctal plug group compared with the no punctal plug group however this difference was small and possibly clinically unimportant (mean difference (MD) in fluorescein staining score -1.50 points, 95% CI -1.88 to -1.12; eyes = 61). Similarly there was a small difference in tear film stability with people in the punctal plug group having more stability (MD 1.93 seconds more, 95% CI 0.67 to 3.20; eyes = 28, low-certainty evidence). The number of artificial tear applications was lower in the punctal plug group compared with the no punctal plugs group in one trial (MD -2.70 applications, 95% CI -3.11 to -2.29; eyes = 61, low-certainty evidence). One trial with low-certainty evidence reported little or no difference between the groups in Schirmer scores, but did not report any quantitative data on aqueous tear production. Very low-certainty evidence on adverse events suggested that events occurred reasonably frequently in the punctal plug group and included epiphora, itching, tenderness and swelling of lids with mucous discharge, and plug displacement.One trial compared punctal plugs with cyclosporine (20 eyes) and one trial compared punctal plugs with oral pilocarpine (55 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.Five trials compared punctal plugs with artificial tears. In one of the trials punctal plugs was combined with artificial tears and compared with artificial tears alone. There was very low-certainty evidence on symptomatic improvement. Low-certainty evidence of little or no improvement in ocular surface staining comparing punctal plugs with artificial tears (MD right eye 0.10 points higher, 0.56 lower to 0.76 higher, MD left eye 0.60 points higher, 0.10 to 1.10 higher) and low-certainty evidence of little or no difference in aqueous tear production (MD 0.00 mm/5 min, 0.33 lower to 0.33 higher)Three trials compared punctal plugs in the upper versus the lower puncta, and none of them reported the review outcomes at long-term follow-up. One trial with very low-certainty evidence reported no observed complications, but it was unclear which complications were collected.One trial compared acrylic punctal plugs with silicone punctal plugs and the trial reported outcomes at approximately 11 weeks of follow-up (36 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.One trial compared intracanalicular punctal plugs with silicone punctal plugs at three months follow-up (57 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.Finally, two trials with very low-certainty evidence compared collagen punctal plugs versus silicone punctal plugs (98 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Although the investigators of the individual trials concluded that punctal plugs are an effective means for treating dry eye signs and symptoms, the evidence in this systematic review suggests that improvements in symptoms and commonly tested dry eye signs are inconclusive. Despite the inclusion of 11 additional trials, the findings of this updated review are consistent with the previous review published in 2010. The type of punctal plug investigated, the type and severity of dry eye being treated, and heterogeneity in trial methodology confounds our ability to make decisive statements regarding the effectiveness of punctal plug use. Although punctal plugs are believed to be relatively safe, their use is commonly associated with epiphora and, less commonly, with inflammatory conditions such as dacryocystitis.

  9. Punctal occlusion for dry eye syndrome

    PubMed Central

    Ervin, Ann-Margret; Law, Andrew; Pucker, Andrew D

    2017-01-01

    Background Dry eye syndrome is a disorder of the tear film that is associated with symptoms of ocular discomfort. Punctal occlusion is a mechanical treatment that blocks the tear drainage system in order to aid in the preservation of natural tears on the ocular surface. Objectives To assess the effects of punctal plugs versus no punctal plugs, different types of punctal plugs, and other interventions for managing dry eye. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 11), MEDLINE Ovid (1946 to 8 December 2016), Embase.com (1947 to 8 December 2016), PubMed (1948 to 8 December 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 8 December 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com; last searched 18 November 2012 - this resource is now archived), ClinicalTrials.gov (www.clinicaltrials.gov; searched 8 December 2016), and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en; searched 8 December 2016). We did not use any date or language restrictions in the electronic searches for trials. We also searched the Science Citation Index-Expanded database and reference lists of included studies. The evidence was last updated on 8 December 2016 Selection criteria We included randomized and quasi-randomized controlled trials of collagen or silicone punctal plugs in symptomatic participants diagnosed with aqueous tear deficiency or dry eye syndrome. Data collection and analysis Two review authors independently assessed trial quality and extracted data. We contacted study investigators for additional information when needed. Main results We included 18 trials (711 participants, 1249 eyes) from Austria, Canada, China, Greece, Japan, Mexico, Netherlands, Turkey, the UK, and the USA in this review. We also identified one ongoing trial. Overall we judged these trials to be at unclear risk of bias because they were poorly reported. We assessed the evidence for eight comparisons. Five trials compared punctal plugs with no punctal plugs (control). Three of these trials employed a sham treatment and two trials observed the control group. Two trials did not report outcome data relevant to this review. There was very low-certainty evidence on symptomatic improvement. The three trials that reported this outcome used different scales to measure symptoms. In all three trials, there was little or no improvement in symptom scores with punctal plugs compared with no punctal plugs. Low-certainty evidence from one trial suggested less ocular surface staining in the punctal plug group compared with the no punctal plug group however this difference was small and possibly clinically unimportant (mean difference (MD) in fluorescein staining score -1.50 points, 95% CI -1.88 to -1.12; eyes = 61). Similarly there was a small difference in tear film stability with people in the punctal plug group having more stability (MD 1.93 seconds more, 95% CI 0.67 to 3.20; eyes = 28, low-certainty evidence). The number of artificial tear applications was lower in the punctal plug group compared with the no punctal plugs group in one trial (MD -2.70 applications, 95% CI -3.11 to -2.29; eyes = 61, low-certainty evidence). One trial with low-certainty evidence reported little or no difference between the groups in Schirmer scores, but did not report any quantitative data on aqueous tear production. Very low-certainty evidence on adverse events suggested that events occurred reasonably frequently in the punctal plug group and included epiphora, itching, tenderness and swelling of lids with mucous discharge, and plug displacement. One trial compared punctal plugs with cyclosporine (20 eyes) and one trial compared punctal plugs with oral pilocarpine (55 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Five trials compared punctal plugs with artificial tears. In one of the trials punctal plugs was combined with artificial tears and compared with artificial tears alone. There was very low-certainty evidence on symptomatic improvement. Low-certainty evidence of little or no improvement in ocular surface staining comparing punctal plugs with artificial tears (MD right eye 0.10 points higher, 0.56 lower to 0.76 higher, MD left eye 0.60 points higher, 0.10 to 1.10 higher) and low-certainty evidence of little or no difference in aqueous tear production (MD 0.00 mm/5 min, 0.33 lower to 0.33 higher) Three trials compared punctal plugs in the upper versus the lower puncta, and none of them reported the review outcomes at long-term follow-up. One trial with very low-certainty evidence reported no observed complications, but it was unclear which complications were collected. One trial compared acrylic punctal plugs with silicone punctal plugs and the trial reported outcomes at approximately 11 weeks of follow-up (36 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. One trial compared intracanalicular punctal plugs with silicone punctal plugs at three months follow-up (57 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Finally, two trials with very low-certainty evidence compared collagen punctal plugs versus silicone punctal plugs (98 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Authors' conclusions Although the investigators of the individual trials concluded that punctal plugs are an effective means for treating dry eye signs and symptoms, the evidence in this systematic review suggests that improvements in symptoms and commonly tested dry eye signs are inconclusive. Despite the inclusion of 11 additional trials, the findings of this updated review are consistent with the previous review published in 2010. The type of punctal plug investigated, the type and severity of dry eye being treated, and heterogeneity in trial methodology confounds our ability to make decisive statements regarding the effectiveness of punctal plug use. Although punctal plugs are believed to be relatively safe, their use is commonly associated with epiphora and, less commonly, with inflammatory conditions such as dacryocystitis. PMID:28649802

  10. Influence of different peg length in glenoid bone loss: A biomechanical analysis regarding primary stability of the glenoid baseplate in reverse shoulder arthroplasty.

    PubMed

    Königshausen, M; Jettkant, B; Sverdlova, N; Ehlert, C; Gessmann, J; Schildhauer, T A; Seybold, D

    2015-01-01

    There is no biomechanical basis to determine the influence of different length of the central peg of the baseplate anchored within the native scapula in glenoid defect reconstruction in cases of degenerative or posttraumatic glenoid bone loss in reversed shoulder arthroplasty. The purpose of this study was to analyse the stability of different peg lengths used in glenoid bone loss in reversed shoulder arthroplasty. Different lengths of metaglene pegs with different depths of peg anchorage performed with or without metaglene screws in sawbone foam blocks were loaded in vertical and horizontal directions for differentiating load capacities. Simulated physiological loadings were then applied to the peg implants to determine the limits of loading in each depth of anchorage. The loading capacity of the implant was reduced as less of the peg was anchored. The vertically loaded implants showed a significantly higher stability, in contrast to those loaded horizontally at a corresponding peg length and depth of anchorage (p < 0.05). The tests revealed that the metaglene screws are more essential for primary stability than is the peg particularly in the vertically directed loadings (2/3 anchored: peg contributed to 28% of the stability, 1/3 anchorage: peg contributed to 12%). Under the second test conditions, the lowest depth of peg anchorage (1/3) resulted in 322 Newtons [N] in the long peg with a vertical loading direction, and in 130 N in the long peg with a horizontal loading direction (p < 0.05). The pegs should be anchored as deeply as possible into the native scapula bone stock. The metaglene screws play a major role in the initial stability, in contrast to the peg, and they become more important when the depth of the peg anchorage is reduced. If possible, four metaglene screws should be used in cases of uncontained bone loss to guarantee the highest stability.

  11. Nonsurgical Management of an Immature Maxillary Central Incisor with Type III Dens Invaginatus Using MTA Plug: A Case Report

    PubMed Central

    Norouzi, Negar; Kazem, Majid; Gohari, Atefeh

    2017-01-01

    Dens invaginatus is a developmental anomaly, caused by deepening of the enamel organ into the dental papilla before calcification of the dental tissues. Teeth with dens invagination are susceptible to early caries and pulp necrosis within a few years of eruption or even before root end closure. This article reports two immature maxillary central incisors with type I and III dens invaginatus which had necrotic pulp and a large periradicular lesion, that were treated successfully by nonsurgical root canal treatment. After apical plug placement, the remaining space was backfilled using warm vertical gutta-percha technique and the crowns were restored by composite restoration. At 6 months of follow up the patient was asymptomatic and probing depths were less than 3 mm. In addition, the reduction in the size of apical radiolucencies was observed by radiographic examinations. This case report revealed that even type III des invaginatus with an open apex and large periapical lesion, can be treated non-surgically using MTA as an apical plug. Although this case report presents a favorable result, further studies with long term follow-up periods are encouraged to support the use of nonsurgical endodontic treatment for type III dens invaginatus. PMID:29225653

  12. HTLV-1 Tax plugs and freezes UPF1 helicase leading to nonsense-mediated mRNA decay inhibition.

    PubMed

    Fiorini, Francesca; Robin, Jean-Philippe; Kanaan, Joanne; Borowiak, Malgorzata; Croquette, Vincent; Le Hir, Hervé; Jalinot, Pierre; Mocquet, Vincent

    2018-01-30

    Up-Frameshift Suppressor 1 Homolog (UPF1) is a key factor for nonsense-mediated mRNA decay (NMD), a cellular process that can actively degrade mRNAs. Here, we study NMD inhibition during infection by human T-cell lymphotropic virus type I (HTLV-1) and characterise the influence of the retroviral Tax factor on UPF1 activity. Tax interacts with the central helicase core domain of UPF1 and might plug the RNA channel of UPF1, reducing its affinity for nucleic acids. Furthermore, using a single-molecule approach, we show that the sequential interaction of Tax with a RNA-bound UPF1 freezes UPF1: this latter is less sensitive to the presence of ATP and shows translocation defects, highlighting the importance of this feature for NMD. These mechanistic insights reveal how HTLV-1 hijacks the central component of NMD to ensure expression of its own genome.

  13. Complications of silicone stent insertion in patients with expiratory central airway collapse.

    PubMed

    Murgu, Septimiu D; Colt, Henri G

    2007-12-01

    Silicone stent insertion is an alternative treatment for expiratory central airway collapse. This study evaluates the complications (mucus plugging, migration, and granulation tissue) associated with stenting in patients who failed medical therapy and were not surgical candidates. Chart review from 15 consecutive patients treated by silicone stent insertion was done over a 2-year period. Outcomes included (1) changes in functional class, extent and severity of airway collapse (graded from 1 to 4 by using a multidimensional system), procedure- and stent-related complications at 48 hours after stent insertion; (2) frequency of stent-related complications; and (3) frequency of emergent flexible and rigid bronchoscopy (scheduled or emergent) over the follow-up period. Mean functional class and severity and extent of airway collapse significantly improved within 48 hours after treatment (p < 0.05). There were no perioperative deaths. Stent-related complications within 48 hours after stent insertion occurred in 3 patients (1 granulation, 1 migration, and 1 mucus plugging). The mean duration of follow-up for the 12 patients who underwent clinical and bronchoscopic follow-up was 188 days. Twenty-six stent-related complications (12 mucus plugs, 8 migrations, and 6 granulation tissues) were seen in 10 of the 12 patients. Five emergent flexible bronchoscopies and 14 rigid bronchoscopies (6 of which were emergent) were performed during the follow-up period. Silicone stent insertion improves functional status immediately after intervention in patients with expiratory central airway collapse, but is associated with a high rate of stent-related complications and need for repeat bronchoscopic interventions.

  14. Solar Space and Water Heating for Hospital --Charlottesville, Virginia

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Solar heating system described in an 86-page report consists of 88 single-glazed selectively-coated baseplate collector modules, hot-water coils in air ducts, domestic-hot-water preheat tank, 3,000 Gallon (11,350-1) concrete urethane-insulated storage tank and other components.

  15. Parallel Fin ORU Thermal Interface for space applications. [Orbital Replaceable Unit

    NASA Technical Reports Server (NTRS)

    Stobb, C. A.; Limardo, Jose G.

    1992-01-01

    The Parallel Fin Thermal Interface has been developed as an Orbital Replaceable Unit (ORU) interface. The interface transfers heat from an ORU baseplate to a Heat Acquisition Plate (HAP) through pairs of fins sandwiched between insert plates that press against the fins with uniform pressure. The insert plates are spread apart for ORU baseplate separation and replacement. Two prototype interfaces with different fin dimensions were built (Model 140 and 380). Interfacing surface samples were found to have roughnesses of 56 to 89 nm. Conductance values of 267 to 420 W/sq m C were obtained for the 140 model in vacuum with interface pressures of 131 to 262 kPa (19 to 38 psi). Vacuum conductances ranging from 176 to 267 W/sq m F were obtained for the 380 model at interface pressures of 97 to 152 kPa (14 and 22 psi). Correlations from several sources were found to agree with test data within 20 percent using thermal math models of the interfaces.

  16. Wave Manipulation in Metamaterials: A LEGO® Bricks Enabled Platform

    NASA Astrophysics Data System (ADS)

    Celli, Paolo; Gonella, Stefano

    In this work, we show how simple, reconfigurable arrangements of LEGO® bricks can be turned into the building blocks of an experimental platform for the investigation of wave phenomena in metamaterial architectures. The approach involves the assembly of reconfigurable specimens consisting of patterns of bricks on a baseplate and the use of a 3D laser vibrometer to reconstruct global and local wave features. The ability to seamlessly transition between different topologies makes this an effective approach for rapid experimental verification and proof of concept in the arena of mechanical metamaterials engineering. The intuitive nature of the brick-and-baseplate assembly paradigm can also be leveraged to implement families of intuitive lab demonstrations with significant didactic and scientific outreach potential. The versatility of the platform is tested through a series of experiments that illustrate a variety of wave manipulation effects, such as waveguiding and seismic isolation, both in periodic and disordered topologies. We acknowledge the support of the National Science Foundation (Grant CMMI-1266089).

  17. Trapped particle stability for the kinetic stabilizer

    NASA Astrophysics Data System (ADS)

    Berk, H. L.; Pratt, J.

    2011-08-01

    A kinetically stabilized axially symmetric tandem mirror (KSTM) uses the momentum flux of low-energy, unconfined particles that sample only the outer end-regions of the mirror plugs, where large favourable field-line curvature exists. The window of operation is determined for achieving magnetohydrodynamic (MHD) stability with tolerable energy drain from the kinetic stabilizer. Then MHD stable systems are analysed for stability of the trapped particle mode. This mode is characterized by the detachment of the central-cell plasma from the kinetic-stabilizer region without inducing field-line bending. Stability of the trapped particle mode is sensitive to the electron connection between the stabilizer and the end plug. It is found that the stability condition for the trapped particle mode is more constraining than the stability condition for the MHD mode, and it is challenging to satisfy the required power constraint. Furthermore, a severe power drain may arise from the necessary connection of low-energy electrons in the kinetic stabilizer to the central region.

  18. Ultracentrifuge for separating fluid mixtures

    DOEpatents

    Lowry, Ralph A.

    1976-01-01

    1. A centrifuge for the separation of fluid mixtures having light and heavy fractions comprising a cylindrical rotor, disc type end-plugs closing the ends of the rotor, means for mounting said rotor for rotation about its cylindrical axis, a housing member enclosing the rotor, a vacuum chamber in said housing about the central portion of the rotor, a collection chamber at each end of the housing, the innermost side of which is substantially formed by the outer face of the end-plug, means for preventing flow of the fluid from the collection chambers to said vacuum chamber, at least one of said end-plugs having a plurality of holes therethrough communicating between the collection chamber adjacent thereto and the inside of the rotor to induce countercurrent flow of the fluid in the centrifuge, means for feeding fluid to be processed into the centrifuge, means communicating with the collection chambers to extract the light and heavy separated fractions of the fluid, and means for rotating the rotor.

  19. Mass flow and velocity profiles in Neurospora hyphae: partial plug flow dominates intra-hyphal transport.

    PubMed

    Abadeh, Aryan; Lew, Roger R

    2013-11-01

    Movement of nuclei, mitochondria and vacuoles through hyphal trunks of Neurospora crassa were vector-mapped using fluorescent markers and green fluorescent protein tags. The vectorial movements of all three were strongly correlated, indicating the central role of mass (bulk) flow in cytoplasm movements in N. crassa. Profiles of velocity versus distance from the hyphal wall did not match the parabolic shape predicted by the ideal Hagen-Poiseuille model of flow at low Reynolds number. Instead, the profiles were flat, consistent with a model of partial plug flow due to the high concentration of organelles in the flowing cytosol. The intra-hyphal pressure gradients were manipulated by localized external osmotic treatments to demonstrate the dependence of velocity (and direction) on pressure gradients within the hyphae. The data support the concept that mass transport, driven by pressure gradients, dominates intra-hyphal transport. The transport occurs by partial plug flow due to the organelles in the cytosol.

  20. A hybrid waveguide cell for the dielectric properties of reservoir rocks

    NASA Astrophysics Data System (ADS)

    Siggins, A. F.; Gunning, J.; Josh, M.

    2011-02-01

    A hybrid waveguide cell is described for broad-band measurements of the dielectric properties of hydrocarbon reservoir rocks. The cell is designed to operate in the radio frequency range of 1 MHz to 1 GHz. The waveguide consists of 50 Ω coaxial lines feeding into a central cylindrical section which contains the sample under test. The central portion of the waveguide acts as a circular waveguide and can accept solid core plugs of 38 mm diameter and lengths from 2 to 150 mm. The central section can also be used as a conventional coaxial waveguide when a central electrode with spring-loaded end collets is installed. In the latter mode the test samples are required to be in the form of hollow cylinders. An additional feature of the cell is that the central section is designed to telescope over a limited range of 1-2 mm with the application of an axial load. Effective pressures up to 35 MPa can be applied to the sample under the condition of uniaxial strain. The theoretical basis of the hybrid waveguide cell is discussed together with calibration results. Two reservoir rocks, a Donnybrook sandstone and a kaolin rich clay, are then tested in the cell, both as hollow cylinders in coaxial mode and in the form of solid core plugs. The complex dielectric properties of the two materials over the bandwidth of 1 MHz to 1 GHz are compared with the results of the two testing methods.

  1. Automated recording of home cage activity and temperature of individual rats housed in social groups: The Rodent Big Brother project

    PubMed Central

    Tse, Karen; Grant, Claire; Keerie, Amy; Simpson, David J.; Pedersen, John C.; Rimmer, Victoria; Leslie, Lauren; Klein, Stephanie K.; Karp, Natasha A.; Sillito, Rowland; Chartsias, Agis; Lukins, Tim; Heward, James; Vickers, Catherine; Chapman, Kathryn; Armstrong, J. Douglas

    2017-01-01

    Measuring the activity and temperature of rats is commonly required in biomedical research. Conventional approaches necessitate single housing, which affects their behavior and wellbeing. We have used a subcutaneous radiofrequency identification (RFID) transponder to measure ambulatory activity and temperature of individual rats when group-housed in conventional, rack-mounted home cages. The transponder location and temperature is detected by a matrix of antennae in a baseplate under the cage. An infrared high-definition camera acquires side-view video of the cage and also enables automated detection of vertical activity. Validation studies showed that baseplate-derived ambulatory activity correlated well with manual tracking and with side-view whole-cage video pixel movement. This technology enables individual behavioral and temperature data to be acquired continuously from group-housed rats in their familiar, home cage environment. We demonstrate its ability to reliably detect naturally occurring behavioral effects, extending beyond the capabilities of routine observational tests and conventional monitoring equipment. It has numerous potential applications including safety pharmacology, toxicology, circadian biology, disease models and drug discovery. PMID:28877172

  2. Automated recording of home cage activity and temperature of individual rats housed in social groups: The Rodent Big Brother project.

    PubMed

    Redfern, William S; Tse, Karen; Grant, Claire; Keerie, Amy; Simpson, David J; Pedersen, John C; Rimmer, Victoria; Leslie, Lauren; Klein, Stephanie K; Karp, Natasha A; Sillito, Rowland; Chartsias, Agis; Lukins, Tim; Heward, James; Vickers, Catherine; Chapman, Kathryn; Armstrong, J Douglas

    2017-01-01

    Measuring the activity and temperature of rats is commonly required in biomedical research. Conventional approaches necessitate single housing, which affects their behavior and wellbeing. We have used a subcutaneous radiofrequency identification (RFID) transponder to measure ambulatory activity and temperature of individual rats when group-housed in conventional, rack-mounted home cages. The transponder location and temperature is detected by a matrix of antennae in a baseplate under the cage. An infrared high-definition camera acquires side-view video of the cage and also enables automated detection of vertical activity. Validation studies showed that baseplate-derived ambulatory activity correlated well with manual tracking and with side-view whole-cage video pixel movement. This technology enables individual behavioral and temperature data to be acquired continuously from group-housed rats in their familiar, home cage environment. We demonstrate its ability to reliably detect naturally occurring behavioral effects, extending beyond the capabilities of routine observational tests and conventional monitoring equipment. It has numerous potential applications including safety pharmacology, toxicology, circadian biology, disease models and drug discovery.

  3. MTA apical plugs in the treatment of traumatized immature teeth with large periapical lesions.

    PubMed

    Cehreli, Zafer C; Sara, Sezgi; Uysal, Serdar; Turgut, Melek D

    2011-02-01

    This case report describes the management of a late-referral case of periapically involved, traumatized immature permanent incisors by endodontic treatment and the use of mineral trioxide aggregate (MTA) apical plugs. A 10-year-old boy was referred to the clinic with a chief complaint of pain in his maxillary central incisors, which had experienced subluxation trauma 2 years earlier. Periapical radiograph of the teeth showed incomplete root development with wide-open apices and large periradicular lesions. The canals were gently debrided using K-files in conjunction with 2.5% NaOCl irrigation and 2% chlorhexidine for final flush. The root canals became asymptomatic after employing the same endodontic regimen for three visits. MTA plugs were placed in the apical area of the root canals, and the rest of the canal space was obturated by warm compaction of gutta-percha and AH Plus sealer. Resolution of the large periapical lesions was observed 2 months after treatment. At 18 months, the periapical areas revealed radiographic evidence of bone healing. Following successful removal of the toxic content of the root canal, placement of MTA plugs resulted in both healing of the periradicular radiolucency and regeneration of the periapical tissue. © 2010 John Wiley & Sons A/S.

  4. DAVE: A plug and play model for distributed multimedia application development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mines, R.F.; Friesen, J.A.; Yang, C.L.

    1994-07-01

    This paper presents a model being used for the development of distributed multimedia applications. The Distributed Audio Video Environment (DAVE) was designed to support the development of a wide range of distributed applications. The implementation of this model is described. DAVE is unique in that it combines a simple ``plug and play`` programming interface, supports both centralized and fully distributed applications, provides device and media extensibility, promotes object reuseability, and supports interoperability and network independence. This model enables application developers to easily develop distributed multimedia applications and create reusable multimedia toolkits. DAVE was designed for developing applications such as videomore » conferencing, media archival, remote process control, and distance learning.« less

  5. UNSEDATED COMPUTED TOMOGRAPHY FOR DIAGNOSIS OF PELVIC CANAL OBSTRUCTION IN A LEOPARD GECKO (EUBLEPHARIS MACULARIUS).

    PubMed

    DeCourcy, Kelly; Hostnik, Eric T; Lorbach, Josh; Knoblaugh, Sue

    2016-12-01

    An adult leopard gecko ( Eublepharis macularius ) presented for lethargy, hyporexia, weight loss, decreased passage of waste, and a palpable caudal coelomic mass. Computed tomography showed a heterogeneous hyperattenuating (∼143 Hounsfield units) structure within the right caudal coelom. The distal colon-coprodeum lumen or urinary bladder was hypothesized as the most likely location for the heterogeneous structure. Medical support consisted of warm water and lubricant enema, as well as a heated environment. Medical intervention aided the passage of a plug comprised centrally of cholesterol and urates with peripheral stratified layers of fibrin, macrophages, heterophils, and bacteria. Within 24 hr, a follow-up computed tomography scan showed resolution of the pelvic canal plug.

  6. Densitometric evaluation of three intra-oral radiographic films.

    PubMed

    Seeliger, J E; Prinsloo, J J

    1989-05-01

    The radiographic, or diagnostic, quality of the processed radiograph depends upon a number of factors, one of the most important being the characteristics of the film. The purpose of this study was to determine which of three intra-oral radiographic films, obtainable in this country, would give the best results in terms of density range, speed, contrast and base plus fog values. Agfa Dentus, Flow X-Ray and Kodak (all speed group D films) were exposed, using a calibrated G.E. 1000 x-ray generator at 65 kVp, 10 mA and 50 impulses (1 second) exposure time. The target-film-distance was 40 cm, the total filtration 2.0 mm Aluminium and the half-value layer 2.7 mm Aluminium equivalent. An aluminium step-wedge with 8 steps, in steps of 1.5 mm, and a natural premolar tooth, with a carious lesion, embedded in acrylic, were used as phantoms. An 8 mm-thick layer of base-plate wax and a 3 mm-thick lead plate were used to simulate tissue-scatter and prevent back-scatter, respectively. To determine the base plug fog value, an unexposed film from the same batch was processed simultaneously with each of the three films evaluated. All processing was done in a Dürr AC 245 L processor with automatic replenishment and a 6-minute cycle. The processing chemicals, viz., Kolchem High Stability X-ray developer and fixer, were mixed and used in strict accordance with the manufacturer's recommendations. The radiographic densities of each step of the step-wedge, and of carious and normal dentine of the phantom tooth, were determined by means of an RMI Digital Densitometer.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. 3D navigated implantation of the glenoid component in reversed shoulder arthroplasty. Feasibility and results in an anatomic study.

    PubMed

    Stübig, Timo; Petri, Maximilian; Zeckey, Christian; Hawi, Nael; Krettek, Christian; Citak, Musa; Meller, Rupert

    2013-12-01

    Reversed shoulder arthroplasty is an alternative to total shoulder arthroplasty for various indications. The long-term results depend on stable bone fixation, and correct positioning of the glenoid component. The potential contribution of image guidance for reversed shoulder arthroplasty procedures was tested in vitro. 27 positioning procedures (15 navigated, 12 non-navigated) of the glenoid baseplate in reverse shoulder arthroplasty were performed by a single experienced orthopaedic surgeon. A Kirschner wire was placed freehand or with the use of a navigated drill guide. For the navigated procedures, a flat detector 3D C-arm with navigation system was used. The Kirschner wire was to be inserted 12 mm from the inferior glenoid, with an inferior tilt of 10° and centrally in the axial scapular axis. The insertion point in the glenoid as well as the position of the K-wire in the axial and sagittal planes were measured. For statistical analysis, t-tests were performed with a significance level of 0.05. The inferior glenoid drilling distance was 14.1 ± 3.4 mm for conventional placement and 15.1 ± 3.4 mm for the navigated procedure (P = 0.19). The inferior tilt showed no significant difference between the two methods (conventional 7.4 ± 5.2°, navigated 7.7 ± 4.9°, P = 0.63). The glenoid version in the axial plane showed significantly higher accuracy for the navigated procedure, with a mean deviation of 1.6 ±4.5° for the navigated procedure compared with 11.5 ± 6.5° for the conventional procedure(P = 0.004). Accurate positioning of the glenoidal baseplate in the axial scapular plane can be improved using 3D C-arm navigation for reversed shoulder arthroplasty. However, computer navigation may not improve the inferior tilt of the component or the position in the inferior glenoid to avoid scapular notching. Nevertheless, further studies are required to confirm these findings in the clinical setup. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Interlocking Toy Building Blocks as Hands-On Learning Modules for Blind and Visually Impaired Chemistry Students

    ERIC Educational Resources Information Center

    Melaku, Samuel; Schreck, James O.; Griffin, Kameron; Dabke, Rajeev B.

    2016-01-01

    Interlocking toy building blocks (e.g., Lego) as chemistry learning modules for blind and visually impaired (BVI) students in high school and undergraduate introductory or general chemistry courses are presented. Building blocks were assembled on a baseplate to depict the relative changes in the periodic properties of elements. Modules depicting…

  9. The "Set Map" Method of Navigation.

    ERIC Educational Resources Information Center

    Tippett, Julian

    1998-01-01

    Explains the "set map" method of using the baseplate compass to solve walkers' navigational needs as opposed to the 1-2-3 method for taking a bearing. The map, with the compass permanently clipped to it, is rotated to the position in which its features have the same orientation as their counterparts on the ground. Includes directions and…

  10. Navajo minettes in the Cerros de las Mujeres, New Mexico

    NASA Astrophysics Data System (ADS)

    Vaniman, D.; Laughlin, A. W.; Gladney, E. S.

    1985-06-01

    The Cerros de las Mujeres in west-central New Mexico are three mafic minette plugs that should be considered part of the Navajo volcanic fields on the central Colorado Plateau. This newly recognized occurrence extends the Navajo volcanic fields to the southeastern margin of the Colorado Plateau, within 45 km of the extensional tectonic setting in which the Mogollon ash-flow tuff cauldrons occur. The Cerros de las Mujeres provide additional evidence for contemporaneous sodic and potassic volcanism within the Navajo volcanic fields.

  11. The fine structure of the terminal segment of the bovine seminiferous tubule.

    PubMed

    Wrobel, K H; Sinowatz, F; Mademann, R

    1982-01-01

    The intratesticular excurrent duct system of the bull is composed of rete testis, tubuli recti, and the terminal segment of the seminiferous tubules. Each terminal segment is surrounded by a vascular plexus and may be subdivided into a transitional region, middle portion, and terminal plug. The modified supporting cells of the middle portion and the terminal plug no longer display the typical Sertoli-Sertoli junctions seen in the transitional region and the seminiferous tubule proper. In the region of the terminal plug a distinct central lumen is generally not observed: spermatozoa and tubular fluid must pass through an intricate system of communicating clefts between the apices of the closely attached modified supporting cells. Vacuoles in the supranuclear region of the cells in the middle portion indicate strong transepithelial fluid transport. In analogy to the epithelium of rete testis and tubuli recti, the supporting cells of the terminal segment are capable of phagocytosing spermatozoa. The vascular plexus investing the terminal segment serves a dual purpose: it is a regulatory device for fluid and sperm transport, as well as an area of increased diapedesis for white blood cells.

  12. Mantle xenolith-xenocryst-bearing monogenetic alkali basaltic lava field from Kutch Basin, Gujarat, Western India: Estimation of magma ascent rate

    NASA Astrophysics Data System (ADS)

    Ray, Arijit; Hatui, Kalyanbrata; Paul, Dalim Kumar; Sen, Gautam; Biswas, S. K.; Das, Brindaban

    2016-02-01

    Kutch rift basin of northwestern India is characterized by a topography that is controlled by a number of fault controlled uplifted blocks. Kutch Mainland Uplift, the largest uplifted block in the central part of the basin, contains alkali basalt plugs and tholeiitic basalt flows of the Deccan age. Alkali plugs often contain small, discoidal mantle xenoliths of spinel lherzolite and spinel wehrlite composition. Olivine occurs as xenocrysts (coarse, fractured, broken olivine grains with embayed margin; Fo> 90), phenocrysts (euhedral, smaller, and less forsteritic ~ Fo80), and as groundmass grains (small, anhedral, Fo75) in these alkali basalts. In a few cases, the alkali plugs are connected with feeder dykes. Based on the width of feeder dykes, on the sizes of the xenocrysts and xenoliths, thickness of alteration rim around olivine xenocryst, we estimate that the alkali magmas erupted at a minimum speed of 0.37 km per hour. The speed was likely greater because of the fact that the xenoliths broke up into smaller fragments as their host magma ascended through the lithosphere.

  13. Method of casting patterned dielectric structures

    DOEpatents

    Poco, John F.; Hrubesh, Lawrence W.

    2001-01-01

    A pattern of dielectric structures are formed directly on a substrate in a single step using sol-gel chemistry and molding procedures. The resulting dielectric structures are useful in vacuum applications for electronic devices. Porous, lightweight structures having a high aspect ratio that are suitable for use as spacers between the faceplate and baseplate of a field emission display can be manufactured using this method.

  14. 76 FR 4224 - Airworthiness Directives; The Boeing Company Model 767-300 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-25

    ... backup structure at the lower VHF antenna cutout at station 1197 + 99 between stringers 39 left and 39... periphery of the VHF antenna baseplate at station 1197 + 99. We are issuing this AD to detect and correct... lower VHF antenna cutout at station 1197 + 99 between stringers 39L and 39R, and corrective actions if...

  15. Thermal characteristics of the 12-gigahertz, 200-watt output stage tube for the communications technology satellite

    NASA Technical Reports Server (NTRS)

    Curren, A. N.

    1978-01-01

    A description of the methods used to measure component temperatures and heat-rejection rates in a simulated space environment on output stage tubes (OST's) developed for the Communications Technology Satellite is presented along with summaries of experimentally determined values. The OST's were operated over the entire anticipated operating drive range, from the dc beam (zero drive) condition to the 6-db overdrive condition. The baseplate temperature was varied from -10 to 58 C with emphasis placed on the testing done at 45 C, the normal anticipated operating temperature. The heat-rejection rate of the OST baseplate ranged from 7.6 W at the dc beam condition to 184.5 W at the 6-db overdrive condition; the heat-rejection rate of the multistage depressed collector (MDC) cover ranged from 192.2 to 155.9 W for the same conditions. The maximum OST temperature measured on the MDC cover was 227 C during a dc beam test. The minimum temperature measured, also on the MDC cover, was -67.5 C at the end of an extended simulated eclipse test period. No effects were observed on the OST thermal characteristics due to vibration testing or temperature-reversal cycle testing.

  16. Reverse Shoulder Arthroplasty for the Treatment of Rotator Cuff Deficiency: A Concise Follow-up, at a Minimum of 10 Years, of Previous Reports.

    PubMed

    Cuff, Derek J; Pupello, Derek R; Santoni, Brandon G; Clark, Rachel E; Frankle, Mark A

    2017-11-15

    We previously evaluated 94 patients (96 shoulders) who underwent reverse shoulder arthroplasty using a central compressive screw with 5.0-mm peripheral locking screws for baseplate fixation and a center of rotation lateral to the glenoid as treatment for end-stage rotator cuff deficiency. The purpose of this study was to report updated results at a minimum follow-up of 10 years. Forty patients (42 shoulders) were available for clinical follow-up. In the patients available for study, implant survivorship, with the end point being revision for any reason, was 90.7%. Since our 5-year report, 2 patients underwent revision surgery; 1 patient sustained a periprosthetic fracture 7 years postoperatively and 1 patient had a dislocation because of chronic shoulder instability at 8 years postoperatively. At a minimum follow-up of 10 years, the patients continued to maintain their improved outcome scores and range of motion, which were comparable with earlier follow-up evaluations. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  17. A Plug in the Pipeline

    ERIC Educational Resources Information Center

    Matthews, Frank J.

    2005-01-01

    It is an adage that holds true in almost any context--practice makes perfect. In golf, like in many other sports, experience is a central factor in success as well. Children who take up golf early have a distinct advantage when they hit high school and begin competing for the attention of college coaches, and the national junior tournaments are…

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Logan, B.G.

    A recently completed two-year study of a commercial tandem mirror reactor design (Mirror Advanced Reactor Study (MARS)) is briefly reviewed. The end plugs are designed for trapped particle stability, MHD ballooning, balanced geodesic curvature, and small radial electric fields in the central cell. New technologies such as lithium-lead blankets, 24T hybrid coils, gridless direct converters and plasma halo vacuum pumps are highlighted.

  19. Immunodiagnostic Techniques for Bacterial Infections

    DTIC Science & Technology

    1981-01-01

    specificity that specific immune sera (the immune response) provides. The early use of immunological diagnosis was to demonstrate circulating antibodies to...testing requirements. 4. Carefully remove punched plugs by suction. 5. Fill the central well with immune serum and the surrounding wells with test...capsulatuni Serum Actinomvcesr israeli Serum Aspergillus fumiqatus Serum Protozoan: Trvnanosoma cruzi Serum Entameaba histolvtica Serum Trichinella sviralis

  20. Transpiration-Cooled Spacecraft-Insulation-Repair Fasteners

    NASA Technical Reports Server (NTRS)

    Camarda, Charles J.; Pettit, Donald R.; Glass, David; Scotti, Stephen J.; Vaughn, Wallace Lee; Rawal, Suraj

    2012-01-01

    Transpiration-cooled fasteners are proposed that operate like an open-loop heat pipe (self-tapping screws, bolts, and spikes) for use in on-orbit repair of thermal- insulation of a space shuttle or other spacecraft. By limiting the temperature rise of such a fastener and of the adjacent repair material and thermal protection system, the transpiration cooling would contribute to the ability of the repair to retain its strength and integrity in the high-heat-flux, oxidizing environment of reentry into the atmosphere of the Earth. A typical fastener according to the proposal would include a hollow refractory-metal, refractory-composite, or ceramic screw or bolt, the central cavity of which would be occupied by a porous refractory- metal or ceramic plug that would act as both a reservoir and a wick for a transpirant liquid. The plug dimensions, the plug material, and the sizes of the pores would be chosen in conjunction with the transpirant liquid so that (1) capillary pumping could be relied upon to transport the liquid to the heated surface, where the liquid would be vaporized, and (2) the amount of liquid would suffice for protecting against the anticipated heat flux and integrated heat load.

  1. 20. Detail, Furnace A, shows the drill used to tap ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Detail, Furnace A, shows the drill used to tap the furnace (at center left) and the 'mud gun' used to close it up with a clay plug (at lower right). Metal chute at center (next to drill) was used to clean out furnace prior to its abandonment. - Central Furnaces, 2650 Broadway, east bank of Cuyahoga River, Cleveland, Cuyahoga County, OH

  2. Control Points To Reduce Movement of Central Nervous System Tissue during Beef Slaughter.

    PubMed

    Aalhus, J L; Thacker, R D; Larsen, I L; Roberts, J C; Price, M A; Juárez, M

    2017-02-01

    Consumption of central nervous system tissue (CNST) from cattle with bovine spongiform encephalopathy (BSE) is thought to cause the human neurological disease, variant Creutzfeldt-Jacob disease. To identify points of cross-contamination of beef carcasses with CNST, 55 young beef cattle were slaughtered and processed through a federally inspected multispecies abattoir. The objectives of this study were to evaluate CNST spread following the placement of a plug in the penetration site of the skull after captive bolt stunning, to evaluate cross-contamination of carcasses before and after splitting, to compare the effects of hot water pasteurization (84°C for 10 s) versus cold water wash (10°C for 30 s) for reducing CNST on the carcass, and to examine other possible sources of cross-contamination in the abattoir. Results indicated that the use of a plastic plug reduced CNST contamination near the bolt penetration site. This study also confirmed that carcass splitting resulted in an increase in CNST contamination at various areas of the carcass. Hot water pasteurization appeared to be an effective means of removing CNST contamination from carcasses in most of the areas sampled.

  3. A Physical Metallurgical Basis for Heat-Affected Zone and Base-Plate Properties of a Microalloyed HSLA Steel.

    DTIC Science & Technology

    1986-12-01

    system.(a) Schematic diagram.(b) Equipment ...... 64 x * T-3136 FIGURE PAGE 13 Details of subsize charpy specimen and Gleeble HAZ microstructural...simulation specimen ......................................... 71 14 Macrograph profile of subsize charpy specimen illustrating notch location. (a) Specimen...shelf impact energy for subsize charpy specimens as a function of distance from the fusion zone boundary for various nominal heat inputs of both

  4. Press-fit stability of an osteochondral autograft: Influence of different plug length and perfect depth alignment.

    PubMed

    Kock, Niels B; Van Susante, Job L C; Buma, Pieter; Van Kampen, Albert; Verdonschot, Nico

    2006-06-01

    Osteochondral autologous transplantation is used for the treatment of full-thickness articular cartilage lesions of a joint. Press-fit stability is an important factor for good survival of the transplanted plugs. 36 plugs of three different lengths were transplanted in fresh-frozen human knees. On one condyle, 3 plugs were exactly matched to the depth of the recipient site ("bottomed" plugs) and on the opposite condyle 3 plugs were 5 mm shorter than the depth of the recipient site ("unbottomed" plugs). Plugs were left protruding and then pushed in until flush, and then to 2 mm below flush level, using a loading apparatus. Longer plugs needed higher forces to begin displacement. At flush level, bottomed plugs needed significantly higher forces than unbottomed plugs to become displaced below flush level (mean forces of 404 N and 131 N, respectively). Shorter bottomed plugs required higher forces than longer bottomed ones. Bottomed plugs generally provide much more stability than unbottomed ones. Short bottomed plugs are more stable than long bottomed plugs. Thus, in clinical practice it is advisable to use short bottomed plugs. If, however, unbottomed plugs are still chosen, the longer the plug the higher the resulting stability will be because of higher frictional forces.

  5. Avoiding superior tilt in reverse shoulder arthroplasty: a review of the literature and technical recommendations.

    PubMed

    Laver, Lior; Garrigues, Grant E

    2014-10-01

    Superior tilt of the baseplate component in reverse total shoulder arthroplasty leads to tensile baseplate forces and may be a contributor to early loosening. The risk factors for this implant malposition include inadequate exposure through a superior approach and superior glenoid bone deficiency that obscures the native glenoid tilt. Here we review our preoperative evaluation and surgical management strategies to avoid superior tilt. Adequate exposure with a superior approach can be achieved but requires not just proper surgical technique but also careful patient selection. We propose that the superior approach be considered only for acute proximal humerus fractures or in patients when the following criteria are met: no prior open surgery on the shoulder; more than 30° of passive external rotation at 0° of abduction; no medial humeral osteophytes; and any superior migration must be reducible with a sulcus test during examination under anesthesia. Avoiding superior tilt when there is significant superior glenoid erosion can be accomplished with humeral head autograft, most easily performed through a deltopectoral approach. Preoperative templating is critical to determine proper graft thickness, inclination, reaming depth, and harvest technique. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Research on ultrasonic excitation for the removal of drilling fluid plug, paraffin deposition plug, polymer plug and inorganic scale plug for near-well ultrasonic processing technology.

    PubMed

    Wang, Zhenjun; Zeng, Jing; Song, Hao; Li, Feng

    2017-05-01

    Near-well ultrasonic processing technology attracts more attention due to its simple operation, high adaptability, low cost and no pollution to the formation. Although this technology has been investigated in detail through laboratory experiments and field tests, systematic and intensive researches are absent for certain major aspects, such as whether ultrasonic excitation is better than chemical agent for any plugs removal; whether ultrasound-chemical combination plug removal technology has the best plugs removal effect. In this paper, the comparison of removing drilling fluid plug, paraffin deposition plug, polymer plug and inorganic scale plug using ultrasonic excitation, chemical agent and ultrasound-chemical combination plug removal technology is investigated. Results show that the initial core permeability and ultrasonic frequency play a significant role in plug removal. Ultrasonic excitation and chemical agent have different impact on different plugs. The comparison results show that the effect of removing any plugs using ultrasound-chemicals composite plug removal technology is obviously better than that using ultrasonic excitation or chemical agent alone. Such conclusion proves that ultrasonic excitation and chemical agent can cause synergetic effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. openBEB: open biological experiment browser for correlative measurements

    PubMed Central

    2014-01-01

    Background New experimental methods must be developed to study interaction networks in systems biology. To reduce biological noise, individual subjects, such as single cells, should be analyzed using high throughput approaches. The measurement of several correlative physical properties would further improve data consistency. Accordingly, a considerable quantity of data must be acquired, correlated, catalogued and stored in a database for subsequent analysis. Results We have developed openBEB (open Biological Experiment Browser), a software framework for data acquisition, coordination, annotation and synchronization with database solutions such as openBIS. OpenBEB consists of two main parts: A core program and a plug-in manager. Whereas the data-type independent core of openBEB maintains a local container of raw-data and metadata and provides annotation and data management tools, all data-specific tasks are performed by plug-ins. The open architecture of openBEB enables the fast integration of plug-ins, e.g., for data acquisition or visualization. A macro-interpreter allows the automation and coordination of the different modules. An update and deployment mechanism keeps the core program, the plug-ins and the metadata definition files in sync with a central repository. Conclusions The versatility, the simple deployment and update mechanism, and the scalability in terms of module integration offered by openBEB make this software interesting for a large scientific community. OpenBEB targets three types of researcher, ideally working closely together: (i) Engineers and scientists developing new methods and instruments, e.g., for systems-biology, (ii) scientists performing biological experiments, (iii) theoreticians and mathematicians analyzing data. The design of openBEB enables the rapid development of plug-ins, which will inherently benefit from the “house keeping” abilities of the core program. We report the use of openBEB to combine live cell microscopy, microfluidic control and visual proteomics. In this example, measurements from diverse complementary techniques are combined and correlated. PMID:24666611

  8. Geomorphic analysis of the Middle Rio Grande-Elephant Butte Reach, New Mexico

    Treesearch

    Tracy Elizabeth Owen

    2012-01-01

    The Elephant Butte Reach spans about 30 miles, beginning from the South Boundary of the Bosque del Apache National Wildlife Refuge (River Mile 73.9) to the "narrows" of the Elephant Butte Reservoir (River Mile 44.65), in central New Mexico. Sediment plugs occasionally form along the Middle Rio Grande, completely blocking the main channel of the river. In 1991...

  9. Constraints on Eruption Dynamics, Mount St. Helens, WA, 2004-2008

    NASA Astrophysics Data System (ADS)

    Schneider, A.; Rempel, A. W.; Cashman, K. V.

    2009-12-01

    Different models have been proposed for the “drumbeat” earthquakes that accompanied recent eruptive behavior at Mount St. Helens. Debate continues as to whether seismicity is related to brittle failure during the extrusion of solid dacite spines, or is the result of hydrothermal fluids interacting with a crack buried in the volcanic edifice. The thermomechanical properties at the interface between conduit magma and the solid plug play a central role in governing the extrusive behavior. To constrain predictions of conditions at this interface, we model the three-phase magma transport from chamber to plug using pMELTS to account for partial crystallization caused by gas exsolution and degassing during ascent. The model predicts that magma compressibility beneath the plug is lower than necessary to release accommodated elastic strain at intervals that match the periods of the drumbeat earthquakes. While our results are not consistent with episodic whole-plug slip, they may nevertheless be compatible with stick-slip behavior on discrete patches of the bounding fault. We supplement our conduit modeling with a quantitative examination of the roughness of slip surfaces. Power spectral analysis of high-resolution digital elevation models yield a power-law relationship, that is similar to results from tectonic faults that have experienced only limited (typically less than 1 meter) amounts of slip. Structural evidence for expansion at different scales may indicate high-temperature deformation near the brittle-ductile transition. Our results suggest that simultaneous magma fracture and expansion may have generated key seismic characteristics including the observed dilatational first motions and moment magnitude-corner frequency scaling consistent with brittle tectonic faults.

  10. Pressure vessel sliding support unit and system using the sliding support unit

    DOEpatents

    Breach, Michael R.; Keck, David J.; Deaver, Gerald A.

    2013-01-15

    Provided is a sliding support and a system using the sliding support unit. The sliding support unit may include a fulcrum capture configured to attach to a support flange, a fulcrum support configured to attach to the fulcrum capture, and a baseplate block configured to support the fulcrum support. The system using the sliding support unit may include a pressure vessel, a pedestal bracket, and a plurality of sliding support units.

  11. Crystal Structure of Bacteriophage SPP1 Distal Tail Protein (gp19.1)

    PubMed Central

    Veesler, David; Robin, Gautier; Lichière, Julie; Auzat, Isabelle; Tavares, Paulo; Bron, Patrick; Campanacci, Valérie; Cambillau, Christian

    2010-01-01

    Siphophage SPP1 infects the Gram-positive bacterium Bacillus subtilis using its long non-contractile tail and tail-tip. Electron microscopy (EM) previously allowed a low resolution assignment of most orf products belonging to these regions. We report here the structure of the SPP1 distal tail protein (Dit, gp19.1). The combination of x-ray crystallography, EM, and light scattering established that Dit is a back-to-back dimer of hexamers. However, Dit fitting in the virion EM maps was only possible with a hexamer located between the tail-tube and the tail-tip. Structure comparison revealed high similarity between Dit and a central component of lactophage baseplates. Sequence similarity search expanded its relatedness to several phage proteins, suggesting that Dit is a docking platform for the tail adsorption apparatus in Siphoviridae infecting Gram-positive bacteria and that its architecture is a paradigm for these hub proteins. Dit structural similarity extends also to non-contractile and contractile phage tail proteins (gpVN and XkdM) as well as to components of the bacterial type 6 secretion system, supporting an evolutionary connection between all these devices. PMID:20843802

  12. A decentralized charging control strategy for plug-in electric vehicles to mitigate wind farm intermittency and enhance frequency regulation

    NASA Astrophysics Data System (ADS)

    Luo, Xiao; Xia, Shiwei; Chan, Ka Wing

    2014-02-01

    This paper proposes a decentralized charging control strategy for a large population of plug-in electric vehicles (PEVs) to neutralize wind power fluctuations so as to improve the regulation of system frequency. Without relying on a central control entity, each PEV autonomously adjusts its charging or discharging power in response to a communal virtual price signal and based on its own urgency level of charging. Simulation results show that under the proposed charging control, the aggregate PEV power can effectively neutralize wind power fluctuations in real-time while differential allocation of neutralization duties among the PEVs can be realized to meet the PEV users' charging requirements. Also, harmful wind-induced cyclic operations in thermal units can be mitigated. As shown in economic analysis, the proposed strategy can create cost saving opportunities for both PEV users and utility.

  13. Determination of CT number and density profile of binderless, pre-treated and tannin-based Rhizophora spp. particleboards using computed tomography imaging and electron density phantom

    NASA Astrophysics Data System (ADS)

    Yusof, Mohd Fahmi Mohd; Hamid, Puteri Nor Khatijah Abdul; Bauk, Sabar; Hashim, Rokiah; Tajuddin, Abdul Aziz

    2015-04-01

    Plug density phantoms were constructed in accordance to CT density phantom model 062M CIRS using binderless, pre-treated and tannin-based Rhizophora Spp. particleboards. The Rhizophora Spp. plug phantoms were scanned along with the CT density phantom using Siemens Somatom Definition AS CT scanner at three CT energies of 80, 120 and 140 kVp. 15 slices of images with 1.0 mm thickness each were taken from the central axis of CT density phantom for CT number and CT density profile analysis. The values were compared to water substitute plug phantom from the CT density phantom. The tannin-based Rhizophora Spp. gave the nearest value of CT number to water substitute at 80 and 120 kVp CT energies with χ2 value of 0.011 and 0.014 respectively while the binderless Rhizphora Spp. gave the nearest CT number to water substitute at 140 kVp CT energy with χ2 value of 0.023. The tannin-based Rhizophora Spp. gave the nearest CT density profile to water substitute at all CT energies. This study indicated the suitability of Rhizophora Spp. particleboard as phantom material for the use in CT imaging studies.

  14. Determination of CT number and density profile of binderless, pre-treated and tannin-based Rhizophora spp. particleboards using computed tomography imaging and electron density phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yusof, Mohd Fahmi Mohd, E-mail: mfahmi@usm.my; Hamid, Puteri Nor Khatijah Abdul; Tajuddin, Abdul Aziz

    2015-04-29

    Plug density phantoms were constructed in accordance to CT density phantom model 062M CIRS using binderless, pre-treated and tannin-based Rhizophora Spp. particleboards. The Rhizophora Spp. plug phantoms were scanned along with the CT density phantom using Siemens Somatom Definition AS CT scanner at three CT energies of 80, 120 and 140 kVp. 15 slices of images with 1.0 mm thickness each were taken from the central axis of CT density phantom for CT number and CT density profile analysis. The values were compared to water substitute plug phantom from the CT density phantom. The tannin-based Rhizophora Spp. gave the nearest valuemore » of CT number to water substitute at 80 and 120 kVp CT energies with χ{sup 2} value of 0.011 and 0.014 respectively while the binderless Rhizphora Spp. gave the nearest CT number to water substitute at 140 kVp CT energy with χ{sup 2} value of 0.023. The tannin-based Rhizophora Spp. gave the nearest CT density profile to water substitute at all CT energies. This study indicated the suitability of Rhizophora Spp. particleboard as phantom material for the use in CT imaging studies.« less

  15. Friction pull plug welding: chamfered heat sink pull plug design

    NASA Technical Reports Server (NTRS)

    Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)

    2005-01-01

    The average strength of a pull plug weld is increased and weak bonding eliminated by providing a dual included angle at the top one third of the pull plug. Plugs using the included angle of the present invention had consistent high strength, no weak bonds and were substantially defect free. The dual angle of the pull plug body increases the heat and pressure of the weld in the region of the top one third of the plug. This allows the plug to form a tight high quality solid state bond. The dual angle was found to be successful in elimination of defects on both small and large plugs.

  16. Friction pull plug welding: dual chamfered plate hole

    NASA Technical Reports Server (NTRS)

    Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)

    2001-01-01

    Friction Pull Plug Welding (FPPW) is a solid state repair process for defects up to one inch in length, only requiring single sided tooling (OSL) for usage on flight hardware. Early attempts with FPPW followed the matching plug/plate geometry precedence of the successful Friction Push Plug Welding program, however no defect free welds were achieved due to substantial plug necking and plug rotational stalling. The dual chamfered hole has eliminated plug rotational stalling, both upon initial plug/plate contact and during welding. Also, the necking of the heated plug metal under a tensile heating/forging load has been eliminated through the usage of the dual chamfered plate hole.

  17. Clearance of a Mucus Plug

    NASA Astrophysics Data System (ADS)

    Bian, Shiyao; Zheng, Ying; Grotberg, James B.

    2008-11-01

    Mucus plugging may occur in pulmonary airways in asthma, chronic obstructive pulmonary disease (COPD) and cystic fibrosis. How to clear the mucus plug is essential and of fundamental importance. Mucus is known to have a yield stress and a mucus plug behaves like a solid plug when the applied stresses are below its yield stress τy. When the local stresses reaches τy, the plug starts to move and can be cleared out of the lung. It is then of great importance to examine how the mucus plug deforms and what is the minimum pressure required to initiate its movement. The present study used the finite element method (FEM) to study the stress distribution and deformation of a solid mucus plug under different pressure loads using ANSYS software. The maximum shear stress is found to occur near the rear transition region of the plug, which can lead to local yielding and flow. The critical pressure increases linearly with the plug length and asymptotes when the plug length is larger than the half channel width. Experimentally a mucus simulant is used to study the process of plug deformation and critical pressure difference required for the plug to propagate. Consistently, the fracture is observed to start at the rear transition region where the plug core connects the films. However, the critical pressure is observed to be dependent on not only the plug length but also the interfacial shape.

  18. [Evidence of lacrimal plugs via high resolution ultrasound].

    PubMed

    Tost, Frank H W; Darman, Jacques

    2003-07-01

    The practical value of high-frequency ultrasound (transducer frequency of 20 MHz) for studying lacrimal plugs positioned into canaliculi was proved. Twelve patients with twenty intracanalicular plugs and two punctum plugs were examined via high-frequency B-scan ultrasonography using 20 MHz transducer (model I3 Sacramento, USA). Detection and localisation of the intracanalicular plugs was made by a 20 MHz sector scanner. The ultrasound examinations were performed 1 - 24 month after the placement of lacrimal plugs. After patient's head positioning, the high-frequency ultrasound investigation was done via immersion fluid (2 % methylcellulose). All patients with dry eye treated by lacrimal plug implant showed echographic structure in the lacrimal canaliculus. In transversal echograms it was possible to image both canaliculi together when the lids were half-closed. Contrary to the normal state, it was not necessary to inject viscous fluid into the canaliculus. High-resolution ultrasound was able to differentiate the normal canaliculus from the findings after plug placement. The echograms can vary from one plug type to another. Highly reflective structures were found after the placement of silicone intracanalicular plugs, e. g. HERRICK-Plug. In contrast, the ultrasonic image taken through acrylic polymer intracanalicular plugs showed homogeneous small reflective inner structure, e. g. SMART-Plug. However, smooth and flat acoustic interface between acrylic polymer plug and the lacrimal canaliculus produced strong echoes. 20 MHz ultrasound seems to be well suited for the detection and localisation of intracanalicular plugs. By use of 20 MHz ultrasound scans it is possible to get high-quality images of the intracanalicular plug and around lacrimal canaliculus. Compared with UBM, the depth of penetration is much higher with negligible resolution. On the whole, we believe that 20 MHz ultrasound can become a useful tool for evaluating the placement of intracanalicular plugs after insertion.

  19. Power management and distribution technology

    NASA Astrophysics Data System (ADS)

    Dickman, John Ellis

    Power management and distribution (PMAD) technology is discussed in the context of developing working systems for a piloted Mars nuclear electric propulsion (NEP) vehicle. The discussion is presented in vugraph form. The following topics are covered: applications and systems definitions; high performance components; the Civilian Space Technology Initiative (CSTI) high capacity power program; fiber optic sensors for power diagnostics; high temperature power electronics; 200 C baseplate electronics; high temperature component characterization; a high temperature coaxial transformer; and a silicon carbide mosfet.

  20. Power management and distribution technology

    NASA Technical Reports Server (NTRS)

    Dickman, John Ellis

    1993-01-01

    Power management and distribution (PMAD) technology is discussed in the context of developing working systems for a piloted Mars nuclear electric propulsion (NEP) vehicle. The discussion is presented in vugraph form. The following topics are covered: applications and systems definitions; high performance components; the Civilian Space Technology Initiative (CSTI) high capacity power program; fiber optic sensors for power diagnostics; high temperature power electronics; 200 C baseplate electronics; high temperature component characterization; a high temperature coaxial transformer; and a silicon carbide mosfet.

  1. Full 3-dimensional digital workflow for multicomponent dental appliances: A proof of concept.

    PubMed

    van der Meer, W Joerd; Vissink, Arjan; Ren, Yijin

    2016-04-01

    The authors used a 3-dimensional (3D) printer and a bending robot to produce a multicomponent dental appliance to assess whether 3D digital models of the dentition are applicable for a full digital workflow. The authors scanned a volunteer's dentition with an intraoral scanner (Lava Chairside Oral Scanner C.O.S., 3M). A digital impression was used to design 2 multicomponent orthodontic appliances. Biocompatible acrylic baseplates were produced with the aid of a 3D printer. The metal springs and clasps were produced by a bending robot. The fit of the 2 appliances was assessed by 2 experienced orthodontists. The authors assessed both orthodontic appliances with the volunteer's dentition and found the fit to be excellent. Clinicians can fully produce a multicomponent dental appliance consisting of both an acrylic baseplate and other parts, such as clasps, springs, or screws, using a digital workflow process without the need for a physical model of the patient's dentition. Plaster models can be superfluous for orthodontic treatment as digital models can be used in all phases of a full digital workflow in orthodontics. The arduous task of making a multicomponent dental appliance that involves bending wires can possibly be replaced by a computer, design software, a 3D printer, and a bending robot. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.

  2. The Baseplate of Lactobacillus delbrueckii Bacteriophage Ld17 Harbors a Glycerophosphodiesterase*

    PubMed Central

    Cornelissen, Anneleen; Sadovskaya, Irina; Vinogradov, Evgeny; Blangy, Stéphanie; Spinelli, Silvia; Casey, Eoghan; Mahony, Jennifer; Noben, Jean-Paul; Dal Bello, Fabio; Cambillau, Christian; van Sinderen, Douwe

    2016-01-01

    Glycerophosphodiester phosphodiesterases (GDPDs; EC 3.1.4.46) typically hydrolyze glycerophosphodiesters to sn-glycerol 3-phosphate (Gro3P) and their corresponding alcohol during patho/physiological processes in bacteria and eukaryotes. GDPD(-like) domains were identified in the structural particle of bacterial viruses (bacteriophages) specifically infecting Gram-positive bacteria. The GDPD of phage 17 (Ld17; GDPDLd17), representative of the group b Lactobacillus delbrueckii subsp. bulgaricus (Ldb)-infecting bacteriophages, was shown to hydrolyze, besides the simple glycerophosphodiester, two complex surface-associated carbohydrates of the Ldb17 cell envelope: the Gro3P decoration of the major surface polysaccharide d-galactan and the oligo(glycerol phosphate) backbone of the partially glycosylated cell wall teichoic acid, a minor Ldb17 cell envelope component. Degradation of cell wall teichoic acid occurs according to an exolytic mechanism, and Gro3P substitution is presumed to be inhibitory for GDPDLd17 activity. The presence of the GDPDLd17 homotrimer in the viral baseplate structure involved in phage-host interaction together with the dependence of native GDPD activity, adsorption, and efficiency of plating of Ca2+ ions supports a role for GDPDLd17 activity during phage adsorption and/or phage genome injection. In contrast to GDPDLd17, we could not identify any enzymatic activity for the GDPD-like domain in the neck passage structure of phage 340, a 936-type Lactococcus lactis subsp. lactis bacteriophage. PMID:27268053

  3. Patterns of surface burrow plugging in a colony of black-tailed prairie dogs occupied by black-footed ferrets

    USGS Publications Warehouse

    Eads, David E.; Biggins, Dean E.

    2012-01-01

    Black-tailed prairie dogs (Cynomys ludovicianus) can surface-plug openings to a burrow occupied by a black-footed ferret (Mustela nigripes). At a coarse scale, surface plugs are more common in colonies of prairie dogs occupied by ferrets than in colonies without ferrets. However, little is known about spatial and temporal patterns of surface plugging in a colony occupied by ferrets. In a 452-ha colony of black-tailed prairie dogs in South Dakota, we sampled burrow openings for surface plugs and related those data to locations of ferrets observed during spotlight surveys. Of 67,574 burrow openings in the colony between June and September 2007, 3.7% were plugged. In a colony-wide grid of 80 m × 80 m cells, the occurrence of surface plugging (≥1 opening plugged) was greater in cells used by ferrets (93.3% of cells) than in cells not observably used by ferrets (70.6%). Rates of surface plugging (percentages of openings plugged) were significantly higher in cells used by ferrets (median = 3.7%) than in cells without known ferret use (median = 3.2%). Also, numbers of ferret locations in cells correlated positively with numbers of mapped surface plugs in the cells. To investigate surface plugging at finer temporal and spatial scales, we compared rates of surface plugging in 20-m-radius circle-plots centered on ferret locations and in random plots 1–4 days after observing a ferret (Jun–Oct 2007 and 2008). Rates of surface plugging were greater in ferret-plots (median = 12.0%) than in random plots (median = 0%). For prairie dogs and their associates, the implications of surface plugging could be numerous. For instance, ferrets must dig to exit or enter plugged burrows (suggesting energetic costs), and surface plugs might influence microclimates in burrows and consequently influence species that cannot excavate soil (e.g., fleas that transmit the plague bacterium Yersinia pestis).

  4. Aeroacoustics of supersonic jet flows from contoured and solid/porous conical plug-nozzles

    NASA Technical Reports Server (NTRS)

    Dosanjh, Darshan S.; Das, Indu S.

    1987-01-01

    The results of an experimental study of the acoustic far-field, the shock associated noise, and the nature of the repetitive shock structure of supersonic jet flows issuing from plug-nozzles having externally-expanded plugs with pointed termination operated at a range of supercritical pressure ratios Xi approaching 2 to 4.5 are reported. The plug of one of these plug-nozzles was contoured. The other plug-nozzles had short conical plugs with either a solid surface or a combination of solid/porous surface of different porosities. The contoured and the uncontoured plug-nozzles had the same throat area and the same annulus-radius ratio K = R sub p/R sub N = 0.43. As the result of modifications of the shock structure, the acoustic performance of improperly expanded jet flows of an externally-expanded short uncontoured plug of an appropriate geometry with suitably perforated plug and a pointed termination, is shown to approach the acoustic performance of a shock-free supersonic jet issuing from an equivalent externally-expanded contoured plug-nozzle.

  5. Friction pull plug welding: top hat plug design

    NASA Technical Reports Server (NTRS)

    Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)

    2001-01-01

    Friction Pull Plug Welding is a solid state repair process for defects up to one inch in length, only requiring single sided tooling, or outside skin line (OSL), for preferred usage on flight hardware. The most prevalent defect associated with Friction Pull Plug Welding (FPPW) was a top side or inside skin line (ISL) lack of bonding. Bonding was not achieved at this location due to the reduction in both frictional heat and welding pressure between the plug and plate at the end of the weld. Thus, in order to eliminate the weld defects and increase the plug strength at the plug `top` a small `hat` section is added to the pull plug for added frictional heating and pressure.

  6. Friction pull plug welding: top hat plug design

    NASA Technical Reports Server (NTRS)

    Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)

    2002-01-01

    Friction Pull Plug Welding is a solid state repair process for defects up to one inch in length, only requiring single sided tooling, or outside skin line (OSL), for preferred usage on flight hardware. The most prevalent defect associated with Friction Pull Plug Welding (FPPW) was a top side or inside skin line (ISL) lack of bonding. Bonding was not achieved at this location due to the reduction in both frictional heat and welding pressure between the plug and plate at the end of the weld. Thus, in order to eliminate the weld defects and increase the plug strength at the plug `top` a small `hat` section is added to the pull plug for added frictional heating and pressure.

  7. Aspergillus fumigatus colonization of punctal plugs.

    PubMed

    Tabbara, Khalid F

    2007-01-01

    Punctal plugs are used in patients with dry eye syndrome to preserve the tears. In this report, I present two cases of Aspergillus fumigatus colonization of punctal plugs. Observational series of two cases. Approval was obtained from the institutional review board. Two men aged 29 and 31 years developed black spots inside the hole of punctal plug, which looked like eyeliner deposits. The deposits inside the hole of the plug in each patient were removed and cultured. Cultures of the two punctal plugs black deposits grew A fumigatus. Bacterial cultures were negative. Colonization of the punctal plug hole with A fumigatus was observed in two cases. It is recommended that punctal plugs be removed in patients undergoing refractive or intraocular procedures or in patients who are receiving topical corticosteroids. Current punctal plugs should be redesigned to avoid the presence of an inserter hole.

  8. Torque limited drive for manual valves

    DOEpatents

    Elliott, Philip G.; Underwood, Daniel E.

    1989-01-01

    The present invention is directed to a torque-limiting handwheel device for preventing manual valves from being damaged due to the application of excessive torque during the opening or closing operation of the valves. Torque can only be applied when ridges in the handwheel assembly engage in channels machined in the face of the baseplate. The amount of torque required for disengagement of the ridges from the channels is determined by the force exerted by various Bellville springs and the inclination of the side faces of the channels.

  9. Torque limited drive for manual valves

    DOEpatents

    Elliott, Philip G.; Underwood, Daniel E.

    1989-06-06

    The present invention is directed to a torque-limiting handwheel device for preventing manual valves from being damaged due to the application of excessive torque during the opening or closing operation of the valves. Torque can only be applied when ridges in the handwheel assembly engage in channels machined in the face of the baseplate. The amount of torque required for disengagement of the ridges from the channels is determined by the force exerted by various Bellville springs and the inclination of the side faces of the channels.

  10. New Technology Sparks Smoother Engines and Cleaner Air

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Automotive Resources, Inc. (ARI) has developed a new device for igniting fuel in engines-the SmartPlug.TM SmartPlug is a self-contained ignition system that may be retrofitted to existing spark-ignition and compression-ignition engines. The SmartPlug needs as little as six watts of power for warm-up, and requires no electricity at all when the engine is running. Unlike traditional spark plugs, once the SmartPlug ignites the engine, and the engine heats up, the power supply for the plug is no longer necessary. In the utility industry, SmartPlugs can be used in tractors, portable generators, compressors, and pumps. In addition to general-purpose applications, such as lawn mowers and chainsaws, SmartPlugs can also be used in the recreational, marine, aviation, and automotive industries. Unlike traditional ignition systems, the SmartPlug system requires no distributor, coil points, or moving parts. SmartPlugs are non-fouling, with a faster and cleaner burn than traditional spark plugs. They prevent detonation and are not sensitive to moisture, allowing them to be used on a variety of engines. Other advantages include no electrical noise, no high voltage, exceptionally high altitude capabilities, and better cold-start statistics than those of standard spark ignition systems. Future applications for the SmartPlug are being evaluated by manufacturers in the snowmobile industry.

  11. Techno-economic comparison of series hybrid, plug-in hybrid, fuel cell and regular cars

    NASA Astrophysics Data System (ADS)

    van Vliet, Oscar P. R.; Kruithof, Thomas; Turkenburg, Wim C.; Faaij, André P. C.

    We examine the competitiveness of series hybrid compared to fuel cell, parallel hybrid, and regular cars. We use public domain data to determine efficiency, fuel consumption, total costs of ownership and greenhouse gas emissions resulting from drivetrain choices. The series hybrid drivetrain can be seen both as an alternative to petrol, diesel and parallel hybrid cars, as well as an intermediate stage towards fully electric or fuel cell cars. We calculate the fuel consumption and costs of four diesel-fuelled series hybrid, four plug-in hybrid and four fuel cell car configurations, and compared these to three reference cars. We find that series hybrid cars may reduce fuel consumption by 34-47%, but cost €5000-12,000 more. Well-to-wheel greenhouse gas emissions may be reduced to 89-103 g CO 2 km -1 compared to reference petrol (163 g km -1) and diesel cars (156 g km -1). Series hybrid cars with wheel motors have lower weight and 7-21% lower fuel consumption than those with central electric motors. The fuel cell car remains uncompetitive even if production costs of fuel cells come down by 90%. Plug-in hybrid cars are competitive when driving large distances on electricity, and/or if cost of batteries come down substantially. Well-to-wheel greenhouse gas emissions may be reduced to 60-69 g CO 2 km -1.

  12. Method of measuring material properties of rock in the wall of a borehole

    DOEpatents

    Overmier, David K.

    1985-01-01

    To measure the modulus of elasticity of the rock in the wall of a borehole, a plug is cut in the borehole wall. The plug, its base attached to the surrounding rock, acts as a short column in response to applied forces. A loading piston is applied to the top of the plug and compression of the plug is measured as load is increased. Measurement of piston load and plug longitudinal deformation are made to determine the elastic modulus of the plug material. Poisson's ratio can be determined by simultaneous measurements of longitudinal and lateral deformation of the plug in response to loading. To determine shear modulus, the top of the plug is twisted while measurements are taken of torsional deformation.

  13. Method of measuring material properties of rock in the wall of a borehole

    DOEpatents

    Overmier, D.K.

    1984-01-01

    To measure the modulus of elasticity of the rock in the wall of a borehole, a plug is cut in the borehole wall. The plug, its base attached to the surrounding rock, acts as a short column in response to applied forces. A loading piston is applied to the top of the plug and compression of the plug is measured as load is increased. Measurements of piston load and plug longitudinal deformation are made to determine the elastic modulus of the plug material. Poisson's ratio can be determined by simultaneous measurements of longitudinal and lateral deformation of the plug in response to loading. To determine shear modulus, the top of the plug is twisted while measurements are taken of torsional deformation.

  14. Final report: Initial ecosystem response of salt marshes to ditch plugging and pool creation: Experiments at Rachel Carson National Wildlife Refuge (Maine)

    USGS Publications Warehouse

    Adamowicz, S.C.; Roman, C.T.

    2002-01-01

    This study evaluates the response of three salt marshes, associated with the Rachel Carson National Wildlife Refuge (Maine), to the practice of ditch plugging. Drainage ditches, originally dug to drain the marsh for mosquito control or to facilitate salt hay farming, are plugged with marsh peat in an effort to impound water upstream of the plug, raise water table levels in the marsh, and increase surface water habitat. At two study sites, Moody Marsh and Granite Point Road Marsh, ditch plugs were installed in spring 2000. Monitoring of hydrology, vegetation, nekton and bird utilization, and marsh development processes was conducted in 1999, before ditch plugging, and then in 2000 and 2001 (all parameters except nekton), after ditch plugging. Each study site had a control marsh that was monitored simultaneously with the plugged marsh, and thus, we employed a BACI study design (before, after, control, impact). A third site, Marshall Point Road Marsh, was plugged in 1998. Monitoring of the plugged and control sites was conducted in 1999 and 2000, with limited monitoring in 2001, thus there was no ?before? plug monitoring. With ditch plugging, water table levels increased toward the marsh surface and the areal extent of standing water increased. Responding to a wetter substrate, a vegetation change from high marsh species (e.g., Spartina patens) to those more tolerant of flooded conditions (e.g., Spartina alterniflora) was noted at two of the three ditch plugged sites. Initial response of the nekton community (fishes and decapod crustaceans) was evaluated by monitoring utilization of salt marsh pools using a 1m2 enclosure trap. In general, nekton species richness, density, and community structure remained unchanged following ditch plugging at the Moody and Granite Point sites. At Marshall Point, species richness and density (number of individuals per m2) were significantly greater in the experimental plugged marsh than the control marsh (<2% of the control marsh was open water habitat vs. 11% of the plugged marsh). The response of birds, categorized as waterfowl & waterbirds, shorebirds & wading birds, gulls & terns, and miscellaneous (raptors, passerines, other), was variable. Following ditch plugging, bird species richness increased at the Granite Point site (1999 pre-plug = 15.4, 2000 post-plug = 26.2, 2001 post-plug = 38.7). Because of a low sample size at Moody Marsh, reliable statements on species richness cannot be made. Density of birds (no. of birds per ha) remained unchanged with ditch plugging at Granite Point Marsh, although there was a strong, but not statistically significant, trend toward increased density. This study only reports on initial responses of marsh functions to ditch plugging. Monitoring should continue at these sites, and perhaps at additional sites, for the next decade or so. A monitoring plan is recommended. Long-term monitoring will include evaluation of salt marsh development processes using SET (surface elevation table) methodology. There is concern, although not confirmed, that as ditch-plugged marshes become wetter and marsh grass production declines their ability to keep pace with sea level rise could be jeopardized. It is suggested that ditch plugging should be considered an experimental marsh management technique. Additional monitoring on the physical and habitat responses of ditch-plugged marshes is required, along with assessments of other techniques aimed at restoring open water habitat to the marsh surface.

  15. Corneal sensitivity, ocular surface health and tear film stability after punctal plug therapy of aqueous deficient dry eye

    PubMed Central

    Said, Azza Mohamed Ahmed; Farag, Mona Elsayed; Abdulla, Tarek Mohamed; Ziko, Othman Ali Othman; Osman, Wesam Mohamed

    2016-01-01

    AIM To evaluate the effect of punctal occlusion using thermosensitive (smart plug) versus silicone plug for management of aqueous deficient dry eye on corneal sensitivity, ocular surface health and tear film stability. METHODS A comparative prospective interventional case study included 45 patients with bilateral severe form of aqueous deficient dry eye. In each patient, the smart plug was inserted in the lower punctum of the right eye which was considered as study group 1 and silicone plug was inserted in the lower punctum of the left eye of the same patient which was considered as study group 2. All patients were subjected to careful history taking and questionnaire for subjective assessment of severity of symptoms. Corneal sensitivity, corneal fluorescein, rose bengal staining, Schirmer's I test, tear film break up time and conjunctival impression cytology were performed pre and 1, 3 and 6mo post plug insertion. RESULTS A statistically significant improvement in subjective and objective manifestations occurred following treatment with both types of plugs (P<0.01). The thermosensitive plug caused significant overall improvement, decrease in frequency of application of tear substitutes and improvement of conjunctival impression cytology parameters in the inserted side (P<0.01). Canaliculitis was reported in two eyes (4.4%) following punctal occlusion using thermosensitive plug (study group 1). Spontaneous plug loss occurred in 21 eyes (46.6%) in the silicone plug group (study group 2). CONCLUSION Improvement of subjective and objective manifestations of aqueous deficient dry eye occurs following punctal plug occlusion. Thermosensitive plug has good patient's compliance with fewer complications and lower rates of loss compared to the silicone plug. PMID:27990362

  16. Experimental study of moving throat plug in a shock tunnel

    NASA Astrophysics Data System (ADS)

    Lee, J. K.; Park, C.; Kwon, O. J.

    2015-07-01

    An experimental study has been carried out to investigate the flow in the KAIST shock tunnel with two moving throat plugs at a primary shock velocity of 1.19 km/s. The nozzle reservoir pressure and the Pitot pressure at the exit of the nozzle were measured to examine the influence of the moving throat plugs on the shock tunnel flow. To assess the present experimental results, comparisons with previous work using a stationary throat plug were made. The mechanism for closing the moving throat plug was developed and verified. The source of the force to move the plug was the pressure generated when the primary shock was reflected at the bottom of the plug. It was observed that the two plugs terminated the shock tunnel flow after the steady flow. .The time for the plugs to terminate the flow showed good agreement with the calculation of the proposed simple analytic solution. There was a negligible difference in flow values such as the reflected pressure and the Pitot pressure between the moving and the stationary plugs.

  17. Data for ground-water test hole near Butte City, Central Valley aquifer project, California

    USGS Publications Warehouse

    French, James J.; Page, R.W.; Bertoldi, G.L.

    1983-01-01

    This report provides preliminary data for the third of seven test holes drilled as part of the Central Valley Aquifer Project which is part of the National Regional Aquifer Systems Analysis Program. The test hole was drilled in the SW 1/4 NE 1/4 sec. 32, T. 19 N., R. 1 W., Glenn County, California, about one-half mile south of the town of Butte City. Drilled to a depth of 1,432 feet below land surface, the hole is cased to a depth of 82 feet and equipped with three piezometer tubes to depths of 592 feet, 968 feet, and 1,330 feet. A 5-foot well screen is at the bottom of each piezometer. Each screened interval has a cement plug above and below it to isolate it from other parts of the aquifer , and the well bore is filled between the plugs with sediment. Nine cores and 49 sidewall cores were recovered. Laboratory tests were made for mineralogy, hydraulic conductivity, porosity , consolidation, grain-size distribution, Atterberg limits, X-ray diffraction, and chemical quality of water. Geophysical and thermal gradient logs were made. The hole is sampled periodically for chemical analysis and measured for water level in the three tapped zones. This report presents methods used to obtain field samples, laboratory procedures, and the data obtained. (USGS)

  18. Data for ground-water test hole near Nicolaus, Central Valley aquifer project, California

    USGS Publications Warehouse

    French, James J.; Page, R.W.; Bertoldi, Gilbert L.

    1983-01-01

    Preliminary data are provided for the third of seven test holes drilled as a part of the Central Valley Aquifer Project which is part of the National Regional Aquifer Systems Analysis Program. The test hole was drilled in the SW 1/4 NE 1/4 sec. 2, T.12N., R.3E., Sutter County, California, about 1 1/2 miles northwest of the town of Nicolaus. Drilled to a depth of 1,150 feet below land surface, the hole is cased to a depth of 100 feet and equipped with three piezometer tubes to depths of 311, 711, and 1,071 feet. A 5-foot well screen is set in sand at the bottom of each piezometer. Each screened interval has a cement plug above and below it to isolate it from other parts of the aquifer, and the well bore is filled between the plugs with sediment. Thirty-one cores and 34 sidewall cores were recovered. Laboratory tests were made for minerology, consolidation, grain-size distribution, Atterberg limits, X-ray diffraction, thermal conductivity, and chemical analysis of water. Geophysical and thermal gradient logs were made. The hole is sampled periodically for chemical analysis of the three tapped zones and measured for water level. This report presents methods used to obtain field samples, laboratory procedures, and the data obtained. (USGS)

  19. Toyota Prius Hybrid Plug-in Conversation and Battery Monitoring system

    NASA Astrophysics Data System (ADS)

    McIntyre, Michael; Kessinger, Robert; Young, Maegan; Latham, Joseph; Unnikannan, Krishnanunni

    2012-02-01

    The objective of the project was to analyze the performance of a Toyota Hybrid. We started off with a stock Toyota Prius and taking data by driving it in city and on the highway in a mixed pre-determined route. The batteries can be charged using standard 120V AC outlets. First phase of the project was to increase the performance of the car by installing 20 Lead (Pb) batteries in a plug-in kit. To improve the performance of the kit, a centralized battery monitoring system was installed. The battery monitoring system has two components, a custom data modules and a National Instruments CompactRIO. Each Pb battery has its own data module and all the data module are connected to the CompactRIO. The CompactRIO records differential voltage, current and temperature from all the 20 batteries. The LabVIEW software is dynamic and can be reconfigured to any number of batteries and real time data from the batteries can be monitored on a LabVIEW enabled machine.

  20. Toyota Prius Hybrid Plug-in Conversation and Battery Monitoring system

    NASA Astrophysics Data System (ADS)

    Unnikannan, Krishnanunni; McIntyre, Michael; Harper, Doug; Kessinger, Robert; Young, Megan; Lantham, Joseph

    2012-03-01

    The objective of the project was to analyze the performance of a Toyota Hybrid. We started off with a stock Toyota Prius and taking data by driving it in city and on the highway in a mixed pre-determined route. The batteries can be charged using standard 120V AC outlets. First phase of the project was to increase the performance of the car by installing 20 Lead (Pb) batteries in a plug-in kit. To improve the performance of the kit, a centralized battery monitoring system was installed. The battery monitoring system has two components, a custom data modules and a National Instruments CompactRIO. Each Pb battery has its own data module and all the data module are connected to the CompactRIO. The CompactRIO records differential voltage, current and temperature from all the 20 batteries. The LabVIEW software is dynamic and can be reconfigured to any number of batteries and real time data from the batteries can be monitored on a LabVIEW enabled machine.

  1. Vascular plugs - A key companion to Interventionists - 'Just Plug it'.

    PubMed

    Ramakrishnan, Sivasubramanian

    2015-01-01

    Vascular plugs are ideally suited to close extra-cardiac, high flowing vascular communications. The family of vascular plugs has expanded. Vascular plugs in general have a lower profile and the newer variants can be delivered even through a diagnostic catheter. These features make them versatile and easy to use. The Amplatzer vascular plugs are also used for closing intracardiac defects including coronary arterio-venous fistula and paravalvular leakage in an off-label fashion. In this review, the features of currently available vascular plugs are reviewed along with tips and tricks of using them in the cardiac catheterization laboratory. Copyright © 2015. Published by Elsevier B.V.

  2. Black-footed ferrets and recreational shooting influence the attributes of black-tailed prairie dog burrows

    USGS Publications Warehouse

    Biggins, Dean E.; Ramakrishnan, Shantini; Goldberg, Amanda R.; Eads, David A.

    2012-01-01

    Black-tailed prairie dogs (Cynomys ludovicianus) plug burrows occupied by black-footed ferrets (Mustela nigripes), and they also plug burrows to entomb dead prairie dogs. We further evaluated these phenomena by sampling connectivity and plugging of burrow openings on prairie dog colonies occupied by ferrets, colonies where recreational shooting was allowed, and colonies with neither shooting nor ferrets. We counted burrow openings on line surveys and within plots, classified surface plugging, and used an air blower to examine subsurface connectivity. Colonies with ferrets had lower densities of openings, fewer connected openings (suggesting increased subsurface plugging), and more surface plugs compared to colonies with no known ferrets. Colonies with recreational shooting had the lowest densities of burrow openings, and line-survey data suggested colonies with shooting had intermediate rates of surface plugging. The extent of surface and subsurface plugging could have consequences for the prairie dog community by changing air circulation and escape routes of burrow systems and by altering energetic relationships. Burrow plugging might reduce prairie dogs' risk of predation by ferrets while increasing risk of predation by American badgers (Taxidea taxus); however, the complexity of the trade-off is increased if plugging increases the risk of predation on ferrets by badgers. Prairie dogs expend more energy plugging and digging when ferrets or shooting are present, and ferrets increase their energy expenditures when they dig to remove those plugs. Microclimatic differences in plugged burrow systems may play a role in flea ecology and persistence of the flea-borne bacterium that causes plague (Yersinia pestis).

  3. Odyne Plug-In Hybrid Electric Utility Truck Testing | Transportation

    Science.gov Websites

    Research | NREL Odyne Plug-In Hybrid Electric Utility Truck Evaluation Odyne Plug-In Hybrid data on plug-in hybrid electric utility trucks operated by a variety of companies. Photo courtesy of Odyne, NREL NREL is evaluating the in-service performance of about 120 plug-in hybrid electric utility

  4. Numerical Simulation of Sediment Plug Formation in Alluvial Channels

    NASA Astrophysics Data System (ADS)

    Posner, A. J.; Duan, J. G.

    2011-12-01

    A sediment plug is the aggregation of sediment in a river reach that completely blocks the original channel resulting in plug growth upstream by accretion and flooding in surrounding areas. Sediment plugs historically form over relatively short periods, in many cases a matter of weeks. Although sediment plugs are much more common in reach constrictions associated with large woody debris, the mouths of tributaries, and along coastal regions, this investigation focuses on sediment plug formation in an alluvial river. During high flows in the years 1991, 1995, 2005, and 2008, a sediment plug formed in the San Marcial reach of the Middle Rio Grande. The Bureau of Reclamation has had to spend millions of dollars dredging the channel to restore flows to Elephant Butte Reservoir. The hydrodynamic and sediment transport processes, associated with plug formation, occurring in this reach are driven by 1) a flow constriction associated with a rock outcrop, 2) a railroad bridge, and 3) the water level of the downstream reservoir. The three-dimensional hydrodynamic model, Delft3D, was implemented to determine the hydrodynamic and sediment transport parameters and variables required to simulate plug formation in an effort to identify hydro- and morphodynamic thresholds. Several variables were identified by previous studies as metrics for plug formation. These variables were used in our investigation to detect the relative magnitude of each process. Both duration and degree of high flow events were simulated, along with extent of cohesive sediment deposits, reservoir level, and percent of fines in suspended sediment distribution. Results of this analysis illustrate that this model is able to reproduce the sediment plug formation. Model calibration was based on measured water levels and changes in bathymetry using both sediment transport and morphologic change parameters. Changes to hydraulic and sediment parameters are not proportional to morphologic changes and are asymptotic in their response. These results suggest that there are thresholds to predict plug formation and that the contribution of specific variables to plug formation is not uniform. Sediment plug formation is a costly and dangerous phenomenon, especially in large alluvial rivers. This investigation yielded specific insights into the hydrodynamic and morphologic processes occurring during sediment plug formation. These insights can be used to reduce the risk of plug formation and predict the locations and times of other sediment plugs.

  5. Method and apparatus for steady-state magnetic measurement of poloidal magnetic field near a tokamak plasma

    DOEpatents

    Woolley, R.D.

    1998-09-08

    A method and apparatus are disclosed for the steady-state measurement of poloidal magnetic field near a tokamak plasma, where the tokamak is configured with respect to a cylindrical coordinate system having z, phi (toroidal), and r axes. The method is based on combining the two magnetic field principles of induction and torque. The apparatus includes a rotor assembly having a pair of inductive magnetic field pickup coils which are concentrically mounted, orthogonally oriented in the r and z directions, and coupled to remotely located electronics which include electronic integrators for determining magnetic field changes. The rotor assembly includes an axle oriented in the toroidal direction, with the axle mounted on pivot support brackets which in turn are mounted on a baseplate. First and second springs are located between the baseplate and the rotor assembly restricting rotation of the rotor assembly about its axle, the second spring providing a constant tensile preload in the first spring. A strain gauge is mounted on the first spring, and electronic means to continually monitor strain gauge resistance variations is provided. Electronic means for providing a known current pulse waveform to be periodically injected into each coil to create a time-varying torque on the rotor assembly in the toroidal direction causes mechanical strain variations proportional to the torque in the mounting means and springs so that strain gauge measurement of the variation provides periodic magnetic field measurements independent of the magnetic field measured by the electronic integrators. 6 figs.

  6. Method and apparatus for steady-state magnetic measurement of poloidal magnetic field near a tokamak plasma

    DOEpatents

    Woolley, Robert D.

    1998-01-01

    A method and apparatus for the steady-state measurement of poloidal magnetic field near a tokamak plasma, where the tokamak is configured with respect to a cylindrical coordinate system having z, phi (toroidal), and r axes. The method is based on combining the two magnetic field principles of induction and torque. The apparatus includes a rotor assembly having a pair of inductive magnetic field pickup coils which are concentrically mounted, orthogonally oriented in the r and z directions, and coupled to remotely located electronics which include electronic integrators for determining magnetic field changes. The rotor assembly includes an axle oriented in the toroidal direction, with the axle mounted on pivot support brackets which in turn are mounted on a baseplate. First and second springs are located between the baseplate and the rotor assembly restricting rotation of the rotor assembly about its axle, the second spring providing a constant tensile preload in the first spring. A strain gauge is mounted on the first spring, and electronic means to continually monitor strain gauge resistance variations is provided. Electronic means for providing a known current pulse waveform to be periodically injected into each coil to create a time-varying torque on the rotor assembly in the toroidal direction causes mechanical strain variations proportional to the torque in the mounting means and springs so that strain gauge measurement of the variation provides periodic magnetic field measurements independent of the magnetic field measured by the electronic integrators.

  7. Design and production of a 2.5 kWe insulated metal substrate-based densely packed CPV assembly

    NASA Astrophysics Data System (ADS)

    Micheli, Leonardo; Sarmah, Nabin; Luo, Xichun; Reddy, K. S.; Mallick, Tapas K.

    2014-09-01

    The original design of a new 144-cell concentrating photovoltaic assembly is presented in this paper. It is conceived to work under 500 suns and to generate about 2.5 kWe. An insulated metal substrate was selected as baseplate, in order to get the best compromise between costs and thermal performances. It is based on a 2mm thick aluminum plate, which is in charge of removing the heat as quick as possible. The copper pattern and thickness has been designed accordingly to the IPC Generic Standard on Printed Board Design and to the restrictions of fit a reflective 125x primary optics and a 4x secondary refractive optics. The original outline of the conductive copper layer has been developed to minimize Joule losses by reducing the number of interconnections between the cells in series. Multijunction solar cells and Schottky bypass diodes have been soldered onto the board as surface mounted components. All the fabrication processes are described. This board represents a novelty for the innovative pattern of the conductive layer, which can be easily adapted to be coupled with different optics geometries and to allocate a different number of cells. The use of an IMS as baseplate will give an experimental contribution to the debate about the exploitability of this kind of substrates in CPV. This board is being characterized indoor and outdoor: the results will be used to improve the design and the reliability of the future receivers.

  8. The Baseplate of Lactobacillus delbrueckii Bacteriophage Ld17 Harbors a Glycerophosphodiesterase.

    PubMed

    Cornelissen, Anneleen; Sadovskaya, Irina; Vinogradov, Evgeny; Blangy, Stéphanie; Spinelli, Silvia; Casey, Eoghan; Mahony, Jennifer; Noben, Jean-Paul; Dal Bello, Fabio; Cambillau, Christian; van Sinderen, Douwe

    2016-08-05

    Glycerophosphodiester phosphodiesterases (GDPDs; EC 3.1.4.46) typically hydrolyze glycerophosphodiesters to sn-glycerol 3-phosphate (Gro3P) and their corresponding alcohol during patho/physiological processes in bacteria and eukaryotes. GDPD(-like) domains were identified in the structural particle of bacterial viruses (bacteriophages) specifically infecting Gram-positive bacteria. The GDPD of phage 17 (Ld17; GDPDLd17), representative of the group b Lactobacillus delbrueckii subsp. bulgaricus (Ldb)-infecting bacteriophages, was shown to hydrolyze, besides the simple glycerophosphodiester, two complex surface-associated carbohydrates of the Ldb17 cell envelope: the Gro3P decoration of the major surface polysaccharide d-galactan and the oligo(glycerol phosphate) backbone of the partially glycosylated cell wall teichoic acid, a minor Ldb17 cell envelope component. Degradation of cell wall teichoic acid occurs according to an exolytic mechanism, and Gro3P substitution is presumed to be inhibitory for GDPDLd17 activity. The presence of the GDPDLd17 homotrimer in the viral baseplate structure involved in phage-host interaction together with the dependence of native GDPD activity, adsorption, and efficiency of plating of Ca(2+) ions supports a role for GDPDLd17 activity during phage adsorption and/or phage genome injection. In contrast to GDPDLd17, we could not identify any enzymatic activity for the GDPD-like domain in the neck passage structure of phage 340, a 936-type Lactococcus lactis subsp. lactis bacteriophage. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  9. Mapping the Tail Fiber as the Receptor Binding Protein Responsible for Differential Host Specificity of Pseudomonas aeruginosa Bacteriophages PaP1 and JG004

    PubMed Central

    Le, Shuai; He, Xuesong; Tan, Yinling; Huang, Guangtao; Zhang, Lin; Lux, Renate; Shi, Wenyuan; Hu, Fuquan

    2013-01-01

    The first step in bacteriophage infection is recognition and binding to the host receptor, which is mediated by the phage receptor binding protein (RBP). Different RBPs can lead to differential host specificity. In many bacteriophages, such as Escherichia coli and Lactococcal phages, RBPs have been identified as the tail fiber or protruding baseplate proteins. However, the tail fiber-dependent host specificity in Pseudomonas aeruginosa phages has not been well studied. This study aimed to identify and investigate the binding specificity of the RBP of P. aeruginosa phages PaP1 and JG004. These two phages share high DNA sequence homology but exhibit different host specificities. A spontaneous mutant phage was isolated and exhibited broader host range compared with the parental phage JG004. Sequencing of its putative tail fiber and baseplate region indicated a single point mutation in ORF84 (a putative tail fiber gene), which resulted in the replacement of a positively charged lysine (K) by an uncharged asparagine (N). We further demonstrated that the replacement of the tail fiber gene (ORF69) of PaP1 with the corresponding gene from phage JG004 resulted in a recombinant phage that displayed altered host specificity. Our study revealed the tail fiber-dependent host specificity in P. aeruginosa phages and provided an effective tool for its alteration. These contributions may have potential value in phage therapy. PMID:23874674

  10. Eddy Current Minimizing Flow Plug for Use in Flow Conditioning and Flow Metering

    NASA Technical Reports Server (NTRS)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor)

    2015-01-01

    An eddy-current-minimizing flow plug has open flow channels formed between the plug's inlet and outlet. Each open flow channel includes (i) a first portion that originates at the inlet face and converges to a location within the plug that is downstream of the inlet, and (ii) a second portion that originates within the plug and diverges to the outlet. The diverging second portion is approximately twice the length of the converging first portion. The plug is devoid of planar surface regions at its inlet and outlet, and in fluid flow planes of the plug that are perpendicular to the given direction of a fluid flowing therethrough.

  11. Protection Against Hearing Loss in General Aviation Operations, Phase II

    NASA Technical Reports Server (NTRS)

    Parker, J. F., Jr.

    1972-01-01

    An inflight evaluation of four aural protectors is presented. The hearing protection devices studied were ear muffs, plastic ear plugs, rubber ear plugs, and wax ear plugs. It is concluded that ear plugs are satisfactory for providing adequate sound attenuation in general aviation aircraft. However, two problems were found in the use of ear plugs; comfort and interference with cabin communications.

  12. Rotating arc spark plug

    DOEpatents

    Whealton, John H.; Tsai, Chin-Chi

    2003-05-27

    A spark plug device includes a structure for modification of an arc, the modification including arc rotation. The spark plug can be used in a combustion engine to reduce emissions and/or improve fuel economy. A method for operating a spark plug and a combustion engine having the spark plug device includes the step of modifying an arc, the modifying including rotating the arc.

  13. Hydrological responses to channelization and the formation of valley plugs and shoals

    USGS Publications Warehouse

    Pierce, Aaron R.; King, Sammy L.

    2017-01-01

    Rehabilitation of floodplain systems focuses on restoring interactions between the fluvial system and floodplain, however, there is a paucity of information on the effects of valley plugs and shoals on floodplain hydrological processes. We investigated hydrologic regimes in floodplains at three valley plug sites, two shoal sites, and three unchannelized sites. Valley plug sites had altered surface and sub-surface hydrology relative to unchannelized sites, while only sub-surface hydrology was affected at shoal sites. Some of the changes were unexpected, such as reduced flood duration and flood depth in floodplains associated with valley plugs. Our results emphasize the variability associated with hydrologic processes around valley plugs and our rudimentary understanding of the effects associated with these geomorphic features. Water table levels were lower at valley plug sites compared to unchannelized sites, however, valley plug sites had a greater proportion of days when water table inundation was above mean root collar depth than both shoal and unchannelized sites as a result of lower root collar depths and higher deposition rates. This study has provided evidence that valley plugs can affect both surface and sub-surface hydrology in different ways than previously thought and illustrates the variability in hydrological responses to valley plug formation.

  14. Comparison of Experimental Data and Computations Fluid Dynamics Analysis for a Three Dimensional Linear Plug Nozzle

    NASA Technical Reports Server (NTRS)

    Ruf, J. H.; Hagemann, G.; Immich, H.

    2003-01-01

    A three dimensional linear plug nozzle of area ratio 12.79 was designed by EADS Space Transportation (former Astrium Space Infrastructure). The nozzle was tested within the German National Technology Program 'LION' in a cold air wind tunnel by TU Dresden. The experimental hardware and test conditions are described. Experimental data was obtained for the nozzle without plug side wall fences at a nozzle pressure ratio of 116 and then with plug side wall fences at NPR 110. Schlieren images were recorded and axial profiles of plug wall static pressures were measured at several spanwise locations and on the plug base. Detailed CFD analysis was performed for these nozzle configurations at NPR 116 by NASA MSFC. The CFD exhibits good agreement with the experimental data. A detailed comparison of the CFD results and the experimental plug wall pressure data are given. Comparisons are made for both the without and with plug side wall fence configurations. Numerical results for density gradient are compared to experimental Schlieren images. Experimental nozzle thrust efficiencies are calculated based on the CFD results. The CFD results are used to illustrate the plug nozzle fluid dynamics. The effect of the plug side wall is emphasized.

  15. Initial Study of Friction Pull Plug Welding

    NASA Technical Reports Server (NTRS)

    Rich, Brian S.

    1999-01-01

    Pull plug friction welding is a new process being developed to conveniently eliminate defects from welded plate tank structures. The general idea is to drill a hole of precise, optimized dimensions and weld a plug into it, filling the hole perfectly. A conically-shaped plug is rotated at high angular velocity as it is brought into contact with the plate material in the hole. As the plug is pulled into the hole, friction rapidly raises the temperature to the point at which the plate material flows plastically. After a brief heating phase, the plug rotation is terminated. The plug is then pulled upon with a forging force, solidly welding the plug into the hole in the plate. Three aspects of this process were addressed in this study. The transient temperature distribution was analyzed based on slightly idealized boundary conditions for different plug geometries. Variations in hole geometry and ram speed were considered, and a program was created to calculate volumes of displaced material and empty space, as well as many other relevant dimensions. The relation between the axially applied forging force and the actual forging pressure between the plate and plug surfaces was determined for various configurations.

  16. Large Plant Growth Chambers: Flying Soon on a Space Station near You!

    NASA Technical Reports Server (NTRS)

    Massa, Gioia D.; Morrow, Robert C.; Levine, Howard G.

    2014-01-01

    The International Space Station (ISS) now has platforms for conducting research on horticultural plant species, and those capabilities continue to grow. The Veggie vegetable production system will be deployed to the ISS in Spring of 2014 to act as an applied research platform with goals of studying food production in space, providing the crew with a source of fresh food, allowing behavioral health and plant microbiology experimentation, and being a source of recreation and enjoyment for the crew. Veggie was conceived, designed, and constructed by Orbital Technologies Corporation (ORBITEC, Madison, WI). Veggie is the largest plant growth chamber that NASA has flown to date, and is capable of growing a wide array of horticultural crops. It was designed for low energy usage, low launch mass and stowage volume, and minimal crew time requirements. The Veggie flight hardware consists of a light cap containing red (630 nanometers), blue, (455 nanometers) and green (530 nanometers) light emitting diodes. Interfacing with the light cap is an extendable bellows baseplate secured to the light cap via magnetic closures and stabilized with extensible flexible arms. The baseplate contains vents allowing air from the ISS cabin to be pulled through the plant growth area by a fan in the light cap. The baseplate holds a Veggie root mat reservoir that will supply water to plant pillows attached via elastic cords. Plant pillows are packages of growth media and seeds that will be sent to ISS dry and installed and hydrated on orbit. Pillows can be constructed in various sizes for different plant types. Watering will be via passive wicking from the root mat to the pillows. Science procedures will include photography or videography, plant thinning, pollination, harvesting, microbial sampling, water sampling, etcetera. Veggie is one of the ISS flight options currently available for research investigations on plants. The Plant Habitat (PH) is being designed and constructed through a NASA-ORBITEC collaboration, and is scheduled to fly on ISS around 2016. This large plant chamber will control light quality, level, and timing, temperature, CO2, relative humidity, and irrigation, while scrubbing ethylene. Additional monitoring capabilities include leaf temperature sensing and root zone moisture and oxygen sensing. The PH light cap will have red (630 nanometers), blue (450 nanometers), green (525 nanometers), far red (730 nanometers) and broad spectrum white light emitting diodes. There will be several internal cameras to monitor and record plant growth and operations.

  17. Geochemical and petrographic data for intrusions peripheral to the Big Timber Stock, Crazy Mountains, Montana

    USGS Publications Warehouse

    du Bray, Edward A.; Van Gosen, Bradley S.

    2015-01-01

    The Paleocene Fort Union Formation hosts a compositionally diverse array of Eocene plugs, dikes, and sills arrayed around the Eocene Big Timber stock in the Crazy Mountains of south-central Montana. The geochemistry and petrography of the sills have not previously been characterized or interpreted. The purpose of this report is (1) to present available geochemical and petrographic data for several dozen samples of these rocks and (2) to provide a basic interpretive synthesis of these data.

  18. The effect of removing plugs and adding arch support to foam based insoles on plantar pressures in people with diabetic peripheral neuropathy.

    PubMed

    Lin, Tung-Liang; Sheen, Huey-Min; Chung, Chin-Teng; Yang, Sai-Wei; Lin, Shih-Yi; Luo, Hong-Ji; Chen, Chung-Yu; Chan, I-Cheng; Shih, Hsu-Sheng; Sheu, Wayne Huey-Herng

    2013-07-29

    Removable plug insoles appear to be beneficial for patients with diabetic neuropathic feet to offload local plantar pressure. However, quantitative evidence of pressure reduction by means of plug removal is limited. The value of additional insole accessories, such as arch additions, has not been tested. The purpose of this study was to evaluate the effect of removing plugs from foam based insoles, and subsequently adding extra arch support, on plantar pressures. In-shoe plantar pressure measurements were performed on 26 patients with diabetic neuropathic feet at a baseline condition, in order to identify the forefoot region with the highest mean peak pressure (MPP). This was defined as the region of interest (ROI) for plug removal.The primary outcome was measurement of MPP using the pedar® system in the baseline and another three insole conditions (pre-plug removal, post-plug removal, and post-plug removal plus arch support). Among the 26 ROIs, a significant reduction in MPP (32.3%, P<0.001) was found after removing the insole plugs. With an arch support added, the pressure was further reduced (9.5%, P<0.001). There were no significant differences in MPP at non-ROIs between pre- and post-plug removal conditions. These findings suggest that forefoot plantar pressure can be reduced by removing plugs and adding arch support to foam-based insoles. This style of insole may therefore be clinically useful in managing patients with diabetic peripheral neuropathy.

  19. Sealed Plant-Growth Chamber For Clinostat

    NASA Technical Reports Server (NTRS)

    Brown, Christopher S.; Dreschel, Thomas W.

    1993-01-01

    Laboratory chamber for growing plants used to measure photosynthesis and respiration in simulated microgravity. Holds plant specimens while rotated on clinostat, see article, "Clinostat Delivers Power To Plant-Growth Cabinets" (KSC-11537). Provides way of comparing gas-exchange rates of plants rotated horizontally on clinostat with those of stationary or vertically rotated plants. Gas extracted for analysis without stopping clinostat. Chamber includes potlike base and cylindrical cover, both made of transparent acrylic pipe. Gasket forms seal between cover and bottom plate of base. Cover bolted to pot baseplate, which in turn bolted to clinostat.

  20. Development and Evaluation of a Sandia Cooler-based Refrigerator Condenser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Terry A.; Kariya, Harumichi Arthur; Leick, Michael T.

    This report describes the first design of a refrigerator condenser using the Sandia Cooler, i.e. air - bearing supported rotating heat - sink impeller. The project included ba seline performance testing of a residential refrigerator, analysis and design development of a Sandia Cooler condenser assembly including a spiral channel baseplate, and performance measurement and validation of this condenser system as incorporated into the residential refrigerator. Comparable performance was achieved in a 60% smaller volume package. The improved modeling parameters can now be used to guide more optimized designs and more accurately predict performance.

  1. A Critical Review on Prosthetic Features Available for Reversed Total Shoulder Arthroplasty

    PubMed Central

    De Wilde, Lieven

    2016-01-01

    Reversed total shoulder arthroplasty is a popular treatment in rotator cuff arthropathy and in displaced proximal humeral fractures in elderly. In 2016, 29 models of commercially available designs express this popularity. This study describes all the different design parameters available on the market. Prosthetic differences are found for the baseplate, glenosphere, polyethylene, and humeral component and these differences need to be weighed out carefully for each patient knowing that a gain in one mechanical parameter can balance the loss of another. Patient specific implants may help in the future. PMID:28105417

  2. Comparison of fracture resistance of simulated immature teeth with an open apex using Biodentine and composite resin: An in vitro study.

    PubMed

    Zhabuawala, Murtuza Saifuddin; Nadig, Roopa R; Pai, Veena S; Gowda, Yashwanth

    2016-01-01

    To evaluate the fracture resistance in simulated immature teeth that had been backfilled using composite resin and Biodentine after using Biodentine as an apical plug material immediately and after 3 months of aging. Sixty extracted human maxillary central incisors were simulated in an immature open apex. The roots of all the specimens were then standardized to a length of 10 mm and canals were instrumented to obtain the radicular dentin thickness around 1.5 mm. All the specimens were then randomly divided into three groups of twenty teeth each. Group I (control) - 4 mm apical plug of Biodentine backfilled with thermoplasticized gutta-percha. Group II - 4 mm apical plug of Biodentine and then backfilled with ParaCore. Group III - completely filled with Biodentine. Ten samples from each group were randomly divided into two subgroups. In subgroup A: Specimens were stored for 1 week. In subgroup B: Specimens were stored in phosphate-buffered saline solution for 3 months and were subjected to universal testing machine. Statistical analysis was done using one-way analysis. No significant difference in fracture resistance between the groups was observed when tested immediately. After 3 months of aging, only Biodentine group showed a significant reduction in fracture resistance without significant reduction with other two groups. Biodentine group has shown a drastic reduction in fracture resistance after 3 months of aging, and hence cannot be recommended as a reinforcement material in immature teeth with thin dentin walls.

  3. On-Chip Titration of an Anticoagulant Argatroban and Determination of the Clotting Time within Whole Blood or Plasma Using a Plug-Based Microfluidic System

    PubMed Central

    Song, Helen; Li, Hung-Wing; Munson, Matthew S.; Van Ha, Thuong G.; Ismagilov, Rustem F.

    2006-01-01

    This paper describes extending plug-based microfluidics to handling complex biological fluids such as blood, solving the problem of injecting additional reagents into plugs, and applying this system to measuring of clotting time in small volumes of whole blood and plasma. Plugs are droplets transported through microchannels by fluorocarbon fluids. A plug-based microfluidic system was developed to titrate an anticoagulant (argatroban) into blood samples and to measure the clotting time using the activated partial thromboplastin time (APTT) test. To carry out these experiments, the following techniques were developed for a plug-based system: (i) using Teflon AF coating on the microchannel wall to enable formation of plugs containing blood and transport of the solid fibrin clots within plugs, (ii) using a hydrophilic glass capillary to enable reliable merging of a reagent from an aqueous stream into plugs, (iii) using bright-field microscopy to detect the formation of a fibrin clot within plugs and using fluorescent microscopy to detect the production of thrombin using a fluorogenic substrate, and (iv) titration of argatroban (0–1.5 μg/mL) into plugs and measurement of the resulting APTTs at room temperature (23 °C) and physiological temperature (37 °C). APTT measurements were conducted with normal pooled plasma (platelet-poor plasma) and with donor’s blood samples (both whole blood and platelet-rich plasma). APTT values and APTT ratios measured by the plug-based microfluidic device were compared to the results from a clinical laboratory at 37 °C. APTT obtained from the on-chip assay were about double those from the clinical laboratory but the APTT ratios from these two methods agreed well with each other. PMID:16841902

  4. Biomass plug development and propagation in porous media.

    PubMed

    Stewart, T L; Fogler, H S

    2001-02-05

    Exopolymer-producing bacteria can be used to modify soil profiles for enhanced oil recovery or bioremediation. Understanding the mechanisms associated with biomass plug development and propagation is needed for successful application of this technology. These mechanisms were determined from packed-bed and micromodel experiments that simulate plugging in porous media. Leuconostoc mesenteroides was used, because production of dextran, a water-insoluble exopolymer, can be controlled by using different carbon sources. As dextran was produced, the pressure drop across the porous media increased and began to oscillate. Three pressure phases were identified under exopolymer-producing conditions: the exopolymer-induction phase, the plugging phase, and the plug-propagation phase. The exopolymer-induction phase extended from the time that exopolymer-producing conditions were induced until there was a measurable increase in pressure drop across the porous media. The plugging phase extended from the first increase in pressure drop until a maximum pressure drop was reached. Changes in pressure drop in these two phases were directly related to biomass distribution. Specifically, flow channels within the porous media filled with biomass creating a plugged region where convective flow occurred only in water channels within the biofilm. These water channels were more restrictive to flow causing the pressure drop to increase. At a maximum pressure drop across the porous media, the biomass yielded much like a Bingham plastic, and a flow channel was formed. This behavior marked the onset of the plug-propagation phase which was characterized by sequential development and breakthrough of biomass plugs. This development and breakthrough propagated the biomass plug in the direction of nutrient flow. The dominant mechanism associated with all three phases of plugging in porous media was exopolymer production; yield stress is an additional mechanism in the plug-propagation phase. Copyright 2001 John Wiley & Sons, Inc.

  5. 75 FR 16657 - Airworthiness Directives; Airbus Model A300 B2-1C, B2K-3C, B2-203, B4-2C, B4-103, and B4-203...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... phasing inspections and magnetic plug inspections for metal particles on the drain plug using detailed... inspections and magnetic plug inspections for metal particles on the drain plug using detailed inspection..., but the magnetic plug inspection reveals metal particles with dimensions greater than 1.5 mm (0.059 in...

  6. 40 CFR 144.63 - Financial assurance for plugging and abandonment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... current plugging and abandonment cost estimate, except as provided in § 144.70(g), divided by the number... days after receiving bills for plugging and abandonment activities, the Regional Administrator will... abandonment activities, the Regional Administrator will determine whether the plugging and abandonment...

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feder, Russell; Youssef, Mahamoud; Klabacha, Jonathan

    USITER is one of seven partner domestic agencies (DA) contributing components to the ITER project. Four diagnostic port plug packages (two equatorial ports and two upper ports) will be engineered and fabricated by Princeton Plasma Physics Lab (PPPL). Diagnostic port plugs as illustrated in Fig. 1 are large primarily stainless steel structures that serve several roles on ITER. The port plugs are the primary vacuum seal and tritium confinement barriers for the vessel. The port plugs also house several plasma diagnostic systems and other machine service equipment. Finally, each port plug must shield high energy neutrons and gamma photons frommore » escaping and creating radiological problems in maintenance areas behind the port plugs. The optimization of the balance between adequate shielding and the need for high performance, high throughput diagnostics systems is the focus of this paper. Neutronics calculations are also needed for assessing nuclear heating and nuclear damage in the port plug and diagnostic components. Attila, the commercially available discrete-ordinates software package, is used for all diagnostic port plug neutronics analysis studies at PPPL.« less

  8. Safety and Efficacy of Lacrimal Drainage System Plugs for Dry Eye Syndrome: A Report by the American Academy of Ophthalmology.

    PubMed

    Marcet, Marcus M; Shtein, Roni M; Bradley, Elizabeth A; Deng, Sophie X; Meyer, Dale R; Bilyk, Jurij R; Yen, Michael T; Lee, W Barry; Mawn, Louise A

    2015-08-01

    To review the published literature assessing the efficacy and safety of lacrimal drainage system plug insertion for dry eye in adults. Literature searches of the PubMed and Cochrane Library databases were last conducted on March 9, 2015, without date restrictions and were limited to English language abstracts. The searches retrieved 309 unique citations. The primary authors reviewed the titles and abstracts. Inclusion criteria specified reports that provided original data on plugs for the treatment of dry eyes in at least 25 patients. Fifty-three studies of potential relevance were assigned to full-text review. The 27 studies that met the inclusion criteria underwent data abstraction by the panels. Abstracted data included study characteristics, patient characteristics, plug type, insertion technique, treatment response, and safety information. All studies were observational and rated by a methodologist as level II or III evidence. The plugs included punctal, intracanalicular, and dissolving types. Fifteen studies reported metrics of improvement in dry eye symptoms, ocular-surface status, artificial tear use, contact lens comfort, and tear break-up time. Twenty-five studies included safety data. Plug placement resulted in ≥50% improvement of symptoms, improvement in ocular-surface health, reduction in artificial tear use, and improved contact lens comfort in patients with dry eye. Serious complications from plugs were infrequent. Plug loss was the most commonly reported problem with punctal plugs, occurring on average in 40% of patients. Overall, among all plug types, approximately 9% of patients experienced epiphora and 10% required removal because of irritation from the plugs. Canaliculitis was the most commonly reported problem for intracanalicular plugs and occurred in approximately 8% of patients. Other complications were reported in less than 4% of patients on average and included tearing, discomfort, pyogenic granuloma, and dacryocystitis. On the basis of level II and III evidence in these studies, plugs improve the signs and symptoms of moderate dry eye that are not improved with topical lubrication, and they are well tolerated. There are no level I studies that describe the efficacy or safety of lacrimal drainage system plugs. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  9. Time-Reversal Based Range Extension Technique for Ultra-Wideband (UWB) Sensors and Applications in Tactical Communications and Networking

    DTIC Science & Technology

    2009-07-16

    Frequency (MHz) Figure 3.4: CABLE SMA/SMA 24" RG-316DS. CABLE SMA PLUG-PLUG HF -.086 8" 3.1. TRANSMITTER IMPLEMENTATION 13 Length: 8.0" (203.2mm) Color...Gray RG Type: Hand Formable .086 Connector: Type SMA Male to SMA Male Features: Shielded "• JI Figure 3.5: CABLE SMA PLUG-PLUG HF -.086 8...34 . • CABLE SMA PLUG-PLUG HF -.141 8" Length: 8.0" (203.2mm) Color: Gray RG Type: Hand Formable .141 14 CHAPTER 3. 2 BY I MISO SYSTEM DEVELOPMENT

  10. Hot cell shield plug extraction apparatus

    DOEpatents

    Knapp, Philip A.; Manhart, Larry K.

    1995-01-01

    An apparatus is provided for moving shielding plugs into and out of holes in concrete shielding walls in hot cells for handling radioactive materials without the use of external moving equipment. The apparatus provides a means whereby a shield plug is extracted from its hole and then swung approximately 90 degrees out of the way so that the hole may be accessed. The apparatus uses hinges to slide the plug in and out and to rotate it out of the way, the hinge apparatus also supporting the weight of the plug in all positions, with the load of the plug being transferred to a vertical wall by means of a bolting arrangement.

  11. 3D CFD Simulation of Plug Dynamics and Splitting through a Bifurcating Airway Model

    NASA Astrophysics Data System (ADS)

    Hoi, Cory; Raessi, Mehdi

    2017-11-01

    Respiratory distress syndrome (RDS) occurs because of pulmonary surfactant insufficiency in the lungs of preterm infants. The common medical procedure to treat RDS, called surfactant respiratory therapy (SRT), involves instilling liquid surfactant plugs into the pulmonary airways. SRT's effectiveness highly depends on the ability to deliver surfactant through the complex branching airway network. Experimental and computational efforts have been made to understand complex fluid dynamics of liquid plug motion through the lung airways in order to increase SRT's response rate. However, previous computational work used 2D airway model geometries and studied plug dynamics of a pre-split plug. In this work, we present CFD simulations of surfactant plug motion through a 3D bifurcating airway model. In our 3D y-tube geometry representing the lung airways, we are not limited by 2D or pre-split plug assumptions. The airway walls are covered with a pre-existing liquid film. Using a passive scalar marking the surfactant plug, the plug splitting and surfactant film deposition is studied under various airway orientations. Exploring the splitting process and liquid distribution in a 3D geometry will advance our understanding of surfactant delivery and will increase the effectiveness of SRT.

  12. Effects of Proud Large Osteochondral Plugs on Contact Forces and Knee Kinematics: A Robotic Study.

    PubMed

    Du, Peter Z; Markolf, Keith L; Boguszewski, Daniel V; Yamaguchi, Kent T; Lama, Christopher J; McAllister, David R; Jones, Kristofer J

    2018-05-01

    Osteochondral allograft (OCA) transplantation is used to treat large focal femoral condylar articular cartilage defects. A proud plug could affect graft survival by altering contact forces (CFs) and knee kinematics. A proud OCA plug will significantly increase CF and significantly alter knee kinematics throughout controlled knee flexion. Controlled laboratory study. Human cadaver knees had miniature load cells, each with a 20-mm-diameter cylinder of native bone/cartilage attached at its exact anatomic position, installed in both femoral condyles at standardized locations representative of clinical defects. Spacers were inserted to create proud plug conditions of +0.5, +1.0, and +1.5 mm. CFs and knee kinematics were recorded as a robot flexed the knee continuously from 0° to 50° under 1000 N of tibiofemoral compression. CFs were increased significantly (vs flush) for all proudness conditions between 0° and 45° of flexion (medial) and 0° to 50° of flexion (lateral). At 20°, the average increases in medial CF for +0.5-mm, +1-mm, and +1.5-mm proudness were +80 N (+36%), +155 N (+70%), and +193 N (+87%), respectively. Corresponding increases with proud lateral plugs were +44 N (+14%), +90 N (+29%), and +118 N (+38%). CF increases for medial plugs at 20° of flexion were significantly greater than those for lateral plugs at all proudness conditions. At 50°, a 1-mm proud lateral plug significantly decreased internal tibial rotation by 15.4° and decreased valgus rotation by 2.5°. A proud medial or lateral plug significantly increased CF between 0° and 45° of flexion. Our results suggest that a medial plug at 20° may be more sensitive to graft incongruity than a lateral plug. The changes in rotational kinematics with proud lateral plugs were attributed to earlier contact between the proud plug's surface and the lateral meniscus, leading to rim impingement with decreased tibial rotation. Increased CF and altered knee kinematics from a proud femoral plug could affect graft viability. Plug proudness of only 0.5 mm produced significant changes in CF and knee kinematics, and the clinically accepted 1-mm tolerance may need to be reexamined in view of our findings.

  13. Aeroacoustics of contoured and solid/porous conical plug-nozzle supersonic jet flows

    NASA Technical Reports Server (NTRS)

    Dosanjh, D. S.; Das, I. S.

    1985-01-01

    The acoustic far field, the shock-associated noise and characteristics of the repetitive shock structure of supersonic jet flows issuing from a contoured plug-nozzle and uncontoured plug-nozzle having a short conical plug of either a solid or a combination of solid/porous surface with pointed termination operated at a range of supercritical pressure are reported. The contoured and the uncontoured plug-nozzles had the same throat area and the same annular-radius ratio.

  14. An objective comparison of leakage between commonly used earplugs.

    PubMed

    Alt, Jeremiah A; Collins, William O

    2012-01-01

    We sought to determine the efficacy of commonly used earplugs using an anatomically correct ear model. The total volume and rate of water that leaked past the earplug and subsequent defect in the tympanic membrane over separately measured 30, 60, 120, and 180-second intervals were recorded. Scenarios tested included a control with no earplug, custom molded earplug (Precision Laboratories, Orlando, FL), Mack's plug (Warren, MI), Doc's plug (Santa Cruz, CA), and cotton balls coated with petroleum jelly. All plugs tested resulted in less leakage at all time points when compared with no plug (P < .05). At 30 seconds, the custom molded, Mack's and Doc's plugs all showed significantly less leakage when compared with the cotton ball coated with petroleum jelly (P < .05). At 60, 120, and 180 seconds, Mack's, Doc's, and the cotton plugs all showed significantly less leakage compared with the customized plug (P < .05). At 120 and 180 seconds, Mack's plugs had significant less leakage than the cotton plug (P < .05). Among the types of plugs, the molded variety (Mack's) showed the least volume and lowest leakage rate (f(4,45) = 94 [P < .001]). In addition, Doc's and cotton balls coated with petroleum jelly were more effective than the customized earplugs. If the clinician feels that middle ear and external canal water exposure should be minimized, then use of earplugs, particularly the moldable variety, merits further consideration. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Electrostatic networks control plug stabilization in the PapC usher.

    PubMed

    Pham, Thieng; Henderson, Nadine S; Werneburg, Glenn T; Thanassi, David G; Delcour, Anne H

    2015-01-01

    The PapC usher, a β-barrel pore in the outer membrane of uropathogenic Escherichia coli, is used for assembly of the P pilus, a key virulence factor in bacterial colonization of human kidney cells. Each PapC protein is composed of a 24-stranded β-barrel channel, flanked by N- and C-terminal globular domains protruding into the periplasm, and occluded by a plug domain (PD). The PD is displaced from the channel towards the periplasm during pilus biogenesis, but the molecular mechanism for PD displacement remains unclear. Two structural features within the β-barrel, an α-helix and β5-6 hairpin loop, may play roles in controlling plug stabilization. Here we have tested clusters of residues at the interface of the plug, barrel, α-helix and hairpin, which participate in electrostatic networks. To assess the roles of these residues in plug stabilization, we used patch-clamp electrophysiology to compare the activity of wild-type and mutant PapC channels containing alanine substitutions at these sites. Mutations interrupting each of two salt bridge networks were relatively ineffective in disrupting plug stabilization. However, mutation of two pairs of arginines located at the inner and the outer surfaces of the PD resulted in an enhanced propensity for plug displacement. One arginine pair involved in a repulsive interaction between the linkers that tether the plug to the β-barrel was particularly sensitive to mutation. These results suggest that plug displacement, which is necessary for pilus assembly and translocation, may require a weakening of key electrostatic interactions between the plug linkers, and the plug and the α-helix.

  16. Production of arrays of chemically distinct nanolitre plugs via repeated splitting in microfluidic devices.

    PubMed

    Adamson, David N; Mustafi, Debarshi; Zhang, John X J; Zheng, Bo; Ismagilov, Rustem F

    2006-09-01

    This paper reports a method for the production of arrays of nanolitre plugs with distinct chemical compositions. One of the primary constraints on the use of plug-based microfluidics for large scale biological screening is the difficulty of fabricating arrays of chemically distinct plugs on the nanolitre scale. Here, using microfluidic devices with several T-junctions linked in series, a single input array of large (approximately 320 nL) plugs was split to produce 16 output arrays of smaller (approximately 20 nL) plugs; the composition and configuration of these arrays were identical to that of the input. This paper shows how the passive break-up of plugs in T-junction microchannel geometries can be used to produce a set of smaller-volume output arrays useful for chemical screening from a single large-volume array. A simple theoretical description is presented to describe splitting as a function of the Capillary number, the capillary pressure, the total pressure difference across the channel, and the geometric fluidic resistance. By accounting for these considerations, plug coalescence and plug-plug contamination can be eliminated from the splitting process and the symmetry of splitting can be preserved. Furthermore, single-outlet splitting devices were implemented with both valve- and volume-based methods for coordinating the release of output arrays. Arrays of plugs containing commercial sparse matrix screens were obtained from the presented splitting method and these arrays were used in protein crystallization trials. The techniques presented in this paper may facilitate the implementation of high-throughput chemical and biological screening.

  17. Alternative Fuels Data Center: Developing Infrastructure to Charge Plug-In

    Science.gov Websites

    Electric Vehicles Developing Infrastructure to Charge Plug-In Electric Vehicles to someone by E -mail Share Alternative Fuels Data Center: Developing Infrastructure to Charge Plug-In Electric Vehicles on Facebook Tweet about Alternative Fuels Data Center: Developing Infrastructure to Charge Plug-In

  18. 40 CFR 146.92 - Injection well plugging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Injection well plugging. 146.92... to Class VI Wells § 146.92 Injection well plugging. (a) Prior to the well plugging, the owner or operator must flush each Class VI injection well with a buffer fluid, determine bottomhole reservoir...

  19. 40 CFR 144.62 - Cost estimate for plugging and abandonment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... must revise the plugging and abandonment cost estimate whenever a change in the plugging and... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Cost estimate for plugging and abandonment. 144.62 Section 144.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER...

  20. A combined Eulerian-Lagrangian two-phase flow analysis of SSME HPOTP nozzle plug trajectories. II - Results

    NASA Technical Reports Server (NTRS)

    Mcconnaughey, P. K.; Garcia, R.; Dejong, F. J.; Sabnis, J. S.; Pribik, D. A.

    1989-01-01

    An analysis of Space Shuttle Main Engine high-pressure oxygen turbopump nozzle plug trajectories has been performed, using a Lagrangian method to track nozzle plug particles expelled from a turbine through a high Reynolds number flow in a turnaround duct with turning vanes. Axisymmetric and parametric analyses reveal that if nozzle plugs exited the turbine they would probably impact the LOX heat exchanger with impact velocities which are significantly less than the penetration velocity. The finding that only slight to moderate damage will result from nozzle plug failure in flight is supported by the results of a hot-fire engine test with induced nozzle plug failures.

  1. Burner rig study of variables involved in hole plugging of air cooled turbine engine vanes

    NASA Technical Reports Server (NTRS)

    Deadmore, D. L.; Lowell, C. E.

    1983-01-01

    The effects of combustion gas composition, flame temperatures, and cooling air mass flow on the plugging of film cooling holes by a Ca-Fe-P-containing deposit were investigated. The testing was performed on film-cooled vanes exposed to the combustion gases of an atmospheric Mach 0.3 burner rig. The extent of plugging was determined by measurement of the open hole area at the conclusion of the tests as well as continuous monitoring of some of the tests using stop-action photography. In general, as the P content increased, plugging rates also increased. The plugging was reduced by increasing flame temperature and cooling air mass flow rates. At times up to approximately 2 hours little plugging was observed. This apparent incubation period was followed by rapid plugging, reaching in several hours a maximum closure whose value depended on the conditions of the test.

  2. Playing with Plug-ins

    ERIC Educational Resources Information Center

    Thompson, Douglas E.

    2013-01-01

    In today's complex music software packages, many features can remain unexplored and unused. Software plug-ins--available in most every music software package, yet easily overlooked in the software's basic operations--are one such feature. In this article, I introduce readers to plug-ins and offer tips for purchasing plug-ins I have…

  3. 40 CFR 144.62 - Cost estimate for plugging and abandonment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Cost estimate for plugging and... Waste Injection Wells § 144.62 Cost estimate for plugging and abandonment. (a) The owner or operator must prepare a written estimate, in current dollars, of the cost of plugging the injection well in...

  4. Steady propagation of Bingham plugs in 2D channels

    NASA Astrophysics Data System (ADS)

    Zamankhan, Parsa; Takayama, Shuichi; Grotberg, James

    2009-11-01

    The displacement of the yield-stress liquid plugs in channels and tubes occur in many biological systems and industrial processes. Among them is the propagation of mucus plugs in the respiratory tracts as may occur in asthma, cystic fibrosis, or emphysema. In this work the steady propagation of mucus plugs in a 2D channel is studied numerically, assuming that the mucus is a pure Bingham fluid. The governing equations are solved by a mixed-discontinuous finite element formulation and the free surface is resolved with the method of spines. The constitutive equation for a pure Bingham fluid is modeled by a regularization method. Fluid inertia is neglected, so the controlling parameters in a steady displacement are; the capillary number, Ca, Bingham number ,Bn, and the plug length. According to the numerical results, the yield stress behavior of the plug modifies the plug shape, the pattern of the streamlines and the distribution of stresses in the plug domain and along the walls in a significant way. The distribution along the walls is a major factor in studying cell injuries. This work is supported through the grant NIH HL84370.

  5. Initial glenoid fixation using two different reverse shoulder designs with an equivalent center of rotation in a low-density and high-density bone substitute.

    PubMed

    Stroud, Nicholas J; DiPaola, Matthew J; Martin, Brian L; Steiler, Cindy A; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; Roche, Christopher P

    2013-11-01

    Numerous glenoid implant designs have been introduced into the global marketplace in recent years; however, little comparative biomechanical data exist to substantiate one design consideration over another. This study dynamically evaluated reverse shoulder glenoid baseplate fixation and compared the initial fixation associated with 2 reverse shoulder designs having an equivalent center of rotation in low-density and high-density bone substitute substrates. Significant differences in fixation were observed between implant designs, where the circular-porous reverse shoulder was associated with approximately twice the micromotion per equivalent test than the oblong-grit-blasted design. Additionally, 6 of the 7 circular-porous reverse shoulders failed catastrophically in the low-density bone model at an average of 2603 ± 981 cycles. None of the oblong-grit-blasted designs failed in the low-or high-density bone models and none of the circular-porous designs failed in the high-density bone models after 10,000 cycles of loading. These results demonstrate that significant differences in initial fixation exist between reverse shoulder implants having an equivalent center of rotation and suggest that design parameters, other than the position of the center of rotation, significantly affect fixation in low-density and high-density polyurethane bone substitutes. Subtle changes in glenoid baseplate design can dramatically affect fixation, particularly in low-density bone substitutes that are intended to simulate the bone quality of the recipient population for reverse shoulders. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  6. Effect of different mixing and placement methods on the quality of MTA apical plug in simulated apexification model.

    PubMed

    Ghasemi, Negin; Janani, Maryam; Razi, Tahmineh; Atharmoghaddam, Faezeh

    2017-03-01

    It is necessary apical plug material to exhibit proper adaptation with the root canal walls. Presence of voids at the interface between the root canal wall and this material result in micro leakage, which might have a relationship with post treatment disease. The aim of the present study was to evaluate the effect of different mixing (manual and ultrasonic) and placement (manual and manual in association with indirect ultrasonic) method of Mineral Trioxide Aggregate (MTA) on the void count and dimension in the apical plug in natural teeth with simulated open apices. Eighty human maxillary central incisors were selected. After simulation of the open apex model, the teeth were assigned to 4 groups based on the mixing and placement techniques of MTA: group 1, manual mixing and manual placement; group 2, manual mixing and manual placement in association with indirect ultrasonic; group 3, ultrasonic mixing and and manual placement; and group 4, ultrasonic mixing and manual placement in association with indirect ultrasonic. The prepared samples were placed within gypsum sockets in which the periodontal ligament was reconstructed with polyether impression material. In group 1, after mixing, the material was condensed with a hand plugger. In group 2, after mixing, the ultrasonic tip was contacted with the hand plugger for 2 seconds. In groups 3 and 4, mixing was carried out with the ultrasonic tip for 5 seconds and in groups 3 and 4, similar to groups 1 and 2, respectively, the materials were placed as apical plugs, measuring 3 mm in length. A wet cotton pellet was placed at canal orifices and dressed with Cavit. After one week, the cone beam computed tomography (CBCT) technique was used to count the number of voids between the material and root canal walls. The void dimensions were determined using the following scoring system: score 1, absence of voids; score 2, the void size less than half of the dimensions of the evaluated cross-section; score 3, the void size larger than half of the dimensions of the evaluated cross-section. Chi-squared and Fisher's exact tests were used for statistical analyses. Statistical significance was set at P <0.05. The maximum (13) and minimum (3) number of voids were detected in groups 2 and 3, respectively. There were no significant differences between groups 1 and 3 in the number of voids ( p >0.05). Evaluation of void dimensions showed no score 3 in any of the study groups and the dimensions of all the voids conformed to score 2. Under the limitations of the present study, use of ultrasonic mixing and manual placement techniques resulted in a decrease in the number of voids in the apical plug. Key words: Apical plug, MTA, ultrasonic, void.

  7. Alternative Fuels Data Center: Charging Plug-In Electric Vehicles in Public

    Science.gov Websites

    in Public to someone by E-mail Share Alternative Fuels Data Center: Charging Plug-In Electric Vehicles in Public on Facebook Tweet about Alternative Fuels Data Center: Charging Plug-In Electric Vehicles in Public on Twitter Bookmark Alternative Fuels Data Center: Charging Plug-In Electric Vehicles in

  8. Plug-In Hybrid Electric Vehicle Basics | NREL

    Science.gov Websites

    Plug-In Hybrid Electric Vehicle Basics Plug-In Hybrid Electric Vehicle Basics Imagine being able to one that's in a standard hybrid electric vehicle. The larger battery pack allows plug-in hybrids to fuel from its onboard tank, and this provides a driving range (the distance a vehicle can travel

  9. Alternative Fuels Data Center: Maintenance and Safety of Hybrid and Plug-In

    Science.gov Websites

    Electric Vehicles Maintenance and Safety of Hybrid and Plug-In Electric Vehicles to someone by E-mail Share Alternative Fuels Data Center: Maintenance and Safety of Hybrid and Plug-In Electric Vehicles on Facebook Tweet about Alternative Fuels Data Center: Maintenance and Safety of Hybrid and Plug

  10. A Report on Superfluid Helium Flow Through Porous Plugs for Space Science Applications

    NASA Technical Reports Server (NTRS)

    Mason, F. C.

    1983-01-01

    As a background for the study of the nature of superfluid helium flow through porous plugs for other space science uses, preliminary tests on various plugs of a given material, diameter, height, and filtration grade have been performed. Two characteristics of the plugs, pore size and number of channels, have been determined by the bubble test and warm flow test of helium gas through the plugs, respectively. Tests on the flow of He II through the plugs have also been performed. An obvious feature of the results of these tests is that for isothermal measurements of pressure versus mass flow rate below approximately 2.10 K, the flow is separated into two different regimes, indicative of the occurrence of a critical phenomenon.

  11. Design and force analysis of end-effector for plug seedling transplanter.

    PubMed

    Jiang, Zhuohua; Hu, Yang; Jiang, Huanyu; Tong, Junhua

    2017-01-01

    Automatic transplanters have been very important in greenhouses since the popularization of seedling nurseries. End-effector development is a key technology for transplanting plug seedlings. Most existing end-effectors have problems with holding root plugs or releasing plugs. An efficient end-effector driven by a linear pneumatic cylinder was designed in this study, which could hold root plugs firmly and release plugs easily. This end-effector with four needles could clamp the plug simultaneously while the needles penetrate into the substrate. The depth and verticality of the needles could be adjusted conveniently for different seedling trays. The effectiveness of this end-effector was tested by a combinational trial examining three seedling nursery factors (the moisture content of the substrate, substrate bulk density and the volume proportion of substrate ingredients). Results showed that the total transplanting success rate for the end-effector was 100%, and the root plug harm rate was below 17%. A force measure system with tension and pressure transducers was installed on the designed end-effector. The adhesive force FL between the root plug and the cell of seedling trays and the extrusion force FK on the root plug were measured and analyzed. The results showed that all three variable factors and their interactions had significant effects on the extrusion force. Each factor had a significant effect on adhesive force. Additionally, it was found that the end-effector did not perform very well when the value of FK/FL was beyond the range of 5.99~8.67. This could provide a scientific basis for end-effector application in transplanting.

  12. Design and force analysis of end-effector for plug seedling transplanter

    PubMed Central

    Hu, Yang; Jiang, Huanyu; Tong, Junhua

    2017-01-01

    Automatic transplanters have been very important in greenhouses since the popularization of seedling nurseries. End-effector development is a key technology for transplanting plug seedlings. Most existing end-effectors have problems with holding root plugs or releasing plugs. An efficient end-effector driven by a linear pneumatic cylinder was designed in this study, which could hold root plugs firmly and release plugs easily. This end-effector with four needles could clamp the plug simultaneously while the needles penetrate into the substrate. The depth and verticality of the needles could be adjusted conveniently for different seedling trays. The effectiveness of this end-effector was tested by a combinational trial examining three seedling nursery factors (the moisture content of the substrate, substrate bulk density and the volume proportion of substrate ingredients). Results showed that the total transplanting success rate for the end-effector was 100%, and the root plug harm rate was below 17%. A force measure system with tension and pressure transducers was installed on the designed end-effector. The adhesive force FL between the root plug and the cell of seedling trays and the extrusion force FK on the root plug were measured and analyzed. The results showed that all three variable factors and their interactions had significant effects on the extrusion force. Each factor had a significant effect on adhesive force. Additionally, it was found that the end-effector did not perform very well when the value of FK/FL was beyond the range of 5.99~8.67. This could provide a scientific basis for end-effector application in transplanting. PMID:28678858

  13. Selenium concentrations in the razorback sucker (Xyrauchen texanus): Substitution of non-lethal muscle plugs for muscle tissue in contaminant assessment

    USGS Publications Warehouse

    Waddell, B.; May, T.

    1995-01-01

    A single muscle plug was collected from each of 25 live razorback suckers inhabiting the Colorado River basin and analyzed for selenium by instrumental neutron activation. Eight fish from Ashley Creek and three from Razorback Bar exhibited selenium concentrations exceeding 8 μg/g, a level associated with reproductive failure in fish. Concentrations of selenium in eggs and milt were significantly correlated with selenium concentrations in muscle plugs and together indicate a possible explanation for the decline of this species in the Colorado River basin. Muscle plugs (<50mg) and muscle tissue (20 g) were collected from dorsal, anterior, and posterior areas of common carp, flannelmouth sucker, and an archived razorback sucker and analyzed for selenium. Concentrations of selenium in muscle plugs were significantly correlated with selenium concentrations in muscle tissue from the same location and fish (r=0.97). Coefficients of variation for selenium concentrations in each fish were <6.5% for muscle tissue, but ranged from 1.5 to 32.4% for muscle plugs. Increased variation in muscle plugs was attributed to lower selenium concentrations found in the anterior muscle plugs of flannelmouth suckers. Mean selenium concentrations in muscle plugs and tissue from dorsal and posterior areas and muscle tissue from the anterior area were not significantly different. The non-lethal collection of a muscle plug from dorsal and posterior areas of the razorback sucker and other fish species may provide an accurate assessment of selenium concentrations that exist in adjacent muscle tissue.

  14. Numerical investigation of soil plugging effect inside sleeve of cast-in-place piles driven by vibratory hammers in clays.

    PubMed

    Xiao, Yong Jie; Chen, Fu Quan; Dong, Yi Zhi

    2016-01-01

    During driving sleeve of cast-in-place piles by vibratory hammers, soils were squeezed into sleeve and then soil plugging was formed. The physic-mechanical properties of the soil plug have direct influence on the load transmission between the sleeve wall and soil plug. Nevertheless, the researches on this issue are insufficient. In this study, finite element and infinite element coupling model was introduced, through the commercial code ABAQUS, to simulate the full penetration process of the sleeve driven from the ground surface to the desired depth by applying vibratory hammers. The research results indicated that the cyclic shearing action decreases both in soil shear strength and in granular cementation force when the sleeve is driven by vibratory hammers, which leads to a partially plugged mode of the soil plug inside the sleeve. Accordingly, the penetration resistance of sleeve driven by vibratory hammers is the smallest compared to those by other installation methods. When driving the sleeve, the annular soil arches forming in the soil plug at sleeve end induce a significant rise in the internal shaft resistance. Moreover, the influence of vibration frequencies, sleeve diameters, and soil layer properties on the soil plug was investigated in detail, and at the same time improved formulas were brought forward to describe the soil plug resistance inside vibratory driven sleeve.

  15. PLUG STORAGE BUILDING, TRA611, AWAITS SHIELDING SOIL TO BE PLACED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PLUG STORAGE BUILDING, TRA-611, AWAITS SHIELDING SOIL TO BE PLACED OVER PLUG STORAGE TUBES. WING WALLS WILL SUPPORT EARTH FILL. MTR, PROCESS WATER BUILDING, AND WORKING RESERVOIR IN VIEW BEYOND PLUG STORAGE. CAMERA FACES NORTHEAST. INL NEGATIVE NO. 2949. Unknown Photographer, 7/30/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  16. Alternative Fuels Data Center: Los Angeles Sets the Stage for Plug-In

    Science.gov Websites

    Electric Vehicles Los Angeles Sets the Stage for Plug-In Electric Vehicles to someone by E-mail Share Alternative Fuels Data Center: Los Angeles Sets the Stage for Plug-In Electric Vehicles on Facebook Tweet about Alternative Fuels Data Center: Los Angeles Sets the Stage for Plug-In Electric

  17. 30 CFR 250.1715 - How must I permanently plug a well?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Zones in open hole, Cement plug(s) set from at least 100 feet below the bottom to 100 feet above the top... cement plug, set by the displacement method, at least 100 feet above and below deepest casing shoe; (ii) A cement retainer with effective back-pressure control set 50 to 100 feet above the casing shoe, and...

  18. 30 CFR 250.1715 - How must I permanently plug a well?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Zones in open hole, Cement plug(s) set from at least 100 feet below the bottom to 100 feet above the top... cement plug, set by the displacement method, at least 100 feet above and below deepest casing shoe; (ii) A cement retainer with effective back-pressure control set 50 to 100 feet above the casing shoe, and...

  19. 30 CFR 250.1715 - How must I permanently plug a well?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Zones in open hole, Cement plug(s) set from at least 100 feet below the bottom to 100 feet above the top... cement plug, set by the displacement method, at least 100 feet above and below deepest casing shoe; (ii) A cement retainer with effective back-pressure control set 50 to 100 feet above the casing shoe, and...

  20. 30 CFR 250.1715 - How must I permanently plug a well?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... in open hole Cement plug(s) set from at least 100 feet below the bottom to 100 feet above the top of... cement plug, set by the displacement method, at least 100 feet above and below deepest casing shoe;(ii) A cement retainer with effective back-pressure control set 50 to 100 feet above the casing shoe, and a...

  1. Electric and Plug-In Hybrid Electric Fleet Vehicle Testing | Transportation

    Science.gov Websites

    Research | NREL Electric and Plug-In Hybrid Electric Fleet Vehicle Evaluations Electric and Plug-In Hybrid Electric Fleet Vehicle Evaluations How Electric and Plug-In Hybrid Electric Vehicles Work EVs use batteries to store the electric energy that powers the motor. EV batteries are charged by

  2. Experimental Investigation of Shock-Cell Noise Reduction for Single Stream Nozzles in Simulated Flight

    NASA Technical Reports Server (NTRS)

    Yamamoto, K.; Brausch, J. F.; Balsa, T. F.; Janardan, B. A.; Knott, P. R.

    1984-01-01

    Seven single stream model nozzles were tested in the Anechoic Free-Jet Acoustic Test Facility to evaluate the effectiveness of convergent divergent (C-D) flowpaths in the reduction of shock-cell noise under both static and mulated flight conditions. The test nozzles included a baseline convergent circular nozzle, a C-D circular nozzle, a convergent annular plug nozzle, a C-D annular plug nozzle, a convergent multi-element suppressor plug nozzle, and a C-D multi-element suppressor plug nozzle. Diagnostic flow visualization with a shadowgraph and aerodynamic plume measurements with a laser velocimeter were performed with the test nozzles. A theory of shock-cell noise for annular plug nozzles with shock-cells in the vicinity of the plug was developed. The benefit of these C-D nozzles was observed over a broad range of pressure ratiosin the vicinity of their design conditions. At the C-D design condition, the C-D annual nozzle was found to be free of shock-cells on the plug.

  3. Integrated geophysical surveys for mapping lati-andesite intrusive bodies, Chino Valley, Arizona

    USGS Publications Warehouse

    El-Kaliouby, Hesham; Sternberg, Ben K.; Hoffmann, John P.; Langenheim, V.E.

    2012-01-01

    Three different geophysical methods (magnetic, transient electromagnetic (TEM) and gravity) were used near Chino Valley, Arizona, USA in order to map a suspected lati-andesite intrusive body (plug) previously located by interpretation of aeromagnetic data. The magnetic and TEM surveys provided the best indication of the location and depth of the plug. The north-south spatial extent of this plug was estimated to be approximately 600 meters. The depth to the top of the plug was found from the TEM survey to be approximately 350 meters near the center of the survey. The location of the plug defined by the ground magnetic data is consistent with that from the TEM data. Gravity data mostly image the basin-basement interface with a small contribution from the plug of about 0.5 mGal. Results from this investigation can be used to help define the irregular subsurface topography caused by several intrusive lati-andesite plugs that could influence groundwater flow in the area.

  4. Static Gas-Charging Plug

    NASA Technical Reports Server (NTRS)

    Indoe, William

    2012-01-01

    A gas-charging plug can be easily analyzed for random vibration. The design features two steeped O-rings in a radial configuration at two different diameters, with a 0.050-in. (.1.3-mm) diameter through-hole between the two O-rings. In the charging state, the top O-ring is engaged and sealing. The bottom O-ring outer diameter is not squeezed, and allows air to flow by it into the tank. The inner diameter is stretched to plug the gland diameter, and is restrained by the O-ring groove. The charging port bushing provides mechanical stop to restrain the plug during gas charge removal. It also prevents the plug from becoming a projectile when removing gas charge from the accumulator. The plug can easily be verified after installation to ensure leakage requirements are met.

  5. High temperature penetrator assembly with bayonet plug and ramp-activated lock

    NASA Technical Reports Server (NTRS)

    Wood, K. E. (Inventor)

    1982-01-01

    A penetration apparatus, for very high temperature applications in which a base plug is inserted into an opening through a bulkhead is described. The base plug has a head shape and is seated against the highest temperature surface of the bulkhead, which may be the skin of the nose cone or other part of a space vehicle intended for nondestructive atmospheric reentry. From the second side of the bulkhead at which the less severe environment is extant, a bayonet plug is inserted into the base plug and engages an internal shoulder at about 90 deg rotation. The bayonet plug has an integral flanged portion and a pair of ramping washers which are located between the flange and the second bulkhead surface with a spacing washer as necessary.

  6. Miniature electrical connector

    DOEpatents

    Casper, Robert F.

    1976-01-01

    A miniature coaxial cable electrical connector includes an annular compressible gasket in a receptacle member, the gasket having a generally triangular cross section resiliently engaging and encircling a conically tapered outer surface of a plug member to create an elongated current leakage path at their interface; means for preventing rotation of the plug relative to the receptacle; a metal sleeve forming a portion of the receptacle and encircling the plug member when interconnected; and a split ring in the plug having outwardly and rearwardly projecting fingers spaced from and encircling a portion of a coaxial cable and engageable with the metal sleeve to interlock the receptacle and plug.

  7. Compensation for Time-Dependent Star Tracker Thermal Deformation on the Aqua Spacecraft

    NASA Technical Reports Server (NTRS)

    Hashmall, Joseph A.; Natanson, Gregory; Glickman, Jonathan; Sedlak, Joseph

    2004-01-01

    Analysis of attitude sensor data from the Aqua mission showed small but systematic differences between batch least-squares and extended Kalman filter attitudes. These differences were also found to be correlated with star tracker residuals, gyro bias estimates, and star tracker baseplate temperatures. This paper describes the analysis that shows that these correlations are all consistent with a single cause: time-dependent thermal deformation of star tracker alignments. These varying alignments can be separated into relative and common components. The relative misalignments can be determined and compensated for. The common misalignments can only be determined in special cases.

  8. COBE ground segment gyro calibration

    NASA Technical Reports Server (NTRS)

    Freedman, I.; Kumar, V. K.; Rae, A.; Venkataraman, R.; Patt, F. S.; Wright, E. L.

    1991-01-01

    Discussed here is the calibration of the scale factors and rate biases for the Cosmic Background Explorer (COBE) spacecraft gyroscopes, with the emphasis on the adaptation for COBE of an algorithm previously developed for the Solar Maximum Mission. Detailed choice of parameters, convergence, verification, and use of the algorithm in an environment where the reference attitudes are determined form the Sun, Earth, and star observations (via the Diffuse Infrared Background Experiment (DIRBE) are considered. Results of some recent experiments are given. These include tests where the gyro rate data are corrected for the effect of the gyro baseplate temperature on the spacecraft electronics.

  9. 40 CFR 147.3108 - Plugging Class I, II, and III wells.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone. (2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of... cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5...

  10. 40 CFR 147.3108 - Plugging Class I, II, and III wells.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone. (2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of... cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5...

  11. 40 CFR 147.3108 - Plugging Class I, II, and III wells.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone. (2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of... cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5...

  12. 40 CFR 147.3108 - Plugging Class I, II, and III wells.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone. (2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of... cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5...

  13. Plug Load Behavioral Change Demonstration Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Metzger, I.; Kandt, A.; VanGeet, O.

    2011-08-01

    This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

  14. 40 CFR 147.3108 - Plugging Class I, II, and III wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone. (2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of... cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5...

  15. A Polymer Plugging Gel for the Fractured Strata and Its Application

    PubMed Central

    Fan, Xiangyu; Zhao, Pengfei; Zhang, Qiangui; Zhang, Ting; Zhu, Kui; Zhou, Chenghua

    2018-01-01

    Well leakage of fractured strata is a tricky problem while drilling. This unwieldy problem is usually caused by the poor formation of the cementing degree, the staggered-mesh of the fracture, and the low bearing capacity of the formation, which can also lead to a narrow and even unsafe window of drilling fluid density. For fractured strata, the normal plugging material has the disadvantages of unsuitable size and low strength, resulting in unsuccessful first time plugging and an increase in cost. Therefore, we developed a polymer plugging gel for the fractured strata, named XNGJ-3. XNGJ-3 is mainly made of an acrylamide monomer and is accompanied by the reactive monomers of carboxyl and hydroxyl as ingredients. XNGJ-3 has a low viscosity before gelling. At 80 °C it becomes gelled, and the gelling time was controlled within the required time of the practical application. These conditions are beneficial for making the plugging material enter the crossing fracture smoothly and occlude the fracture. XNGJ-3 also has a good deformability and can avoid being damaged during the process of fracture closure. The well leakage simulated experiment revealed that the bearing capacity of this material can reach 21 MPa and the inverse bearing capacity can reach 20 MPa. These strengths are more than twice that of common polymer plugging gels. Finally, three leaked wells in the fractured strata of the Sichuan Basin were used to verify the plugging effect of XNGJ-3. Compared with other common plugging materials, XNGJ-3 has the advantages of having a higher success rate of first time plugging, a lower economic cost, a shorter work time, and so forth, which indicate that this plugging material has a good engineering application value in dealing with well leakage of fractured strata. PMID:29883407

  16. The diagnostic performance of leak-plugging automated segmentation versus manual tracing of breast lesions on ultrasound images.

    PubMed

    Xiong, Hui; Sultan, Laith R; Cary, Theodore W; Schultz, Susan M; Bouzghar, Ghizlane; Sehgal, Chandra M

    2017-05-01

    To assess the diagnostic performance of a leak-plugging segmentation method that we have developed for delineating breast masses on ultrasound images. Fifty-two biopsy-proven breast lesion images were analyzed by three observers using the leak-plugging and manual segmentation methods. From each segmentation method, grayscale and morphological features were extracted and classified as malignant or benign by logistic regression analysis. The performance of leak-plugging and manual segmentations was compared by: size of the lesion, overlap area ( O a ) between the margins, and area under the ROC curves ( A z ). The lesion size from leak-plugging segmentation correlated closely with that from manual tracing ( R 2 of 0.91). O a was higher for leak plugging, 0.92 ± 0.01 and 0.86 ± 0.06 for benign and malignant masses, respectively, compared to 0.80 ± 0.04 and 0.73 ± 0.02 for manual tracings. Overall O a between leak-plugging and manual segmentations was 0.79 ± 0.14 for benign and 0.73 ± 0.14 for malignant lesions. A z for leak plugging was consistently higher (0.910 ± 0.003) compared to 0.888 ± 0.012 for manual tracings. The coefficient of variation of A z between three observers was 0.29% for leak plugging compared to 1.3% for manual tracings. The diagnostic performance, size measurements, and observer variability for automated leak-plugging segmentations were either comparable to or better than those of manual tracings.

  17. Dust-tolerant electrical connector

    NASA Technical Reports Server (NTRS)

    Sadick, Shazad (Inventor); Herman, Jason (Inventor); Roberts, Dustyn (Inventor)

    2011-01-01

    A connector assembly includes releasably mateable plug and receptacle units. At least one socket is enclosed within the receptacle unit and is aligned with at least one permeable membrane disposed in the front end of the receptacle unit. The plug unit includes a body slidably mounted within a longitudinal bore therein. At least one pin extends from the front end of the body and is aligned with at least one permeable membrane disposed in the front end of the plug unit. The plug unit is biased toward a first, de-mate position in which the body is extended rearwardly such that the pin is enclosed with the plug unit and is slidable to a second, mate position in which the body is compressed forwardly such that the pin projects through the permeable membranes of the plug and receptacle units to electrically connect with the socket.

  18. Self locking drive system for rotating plug of a nuclear reactor

    DOEpatents

    Brubaker, James E.

    1979-01-01

    This disclosure describes a self locking drive system for rotating the plugs on the head of a nuclear reactor which is able to restrain plug motion if a seismic event should occur during reactor refueling. A servomotor is engaged via a gear train and a bull gear to the plug. Connected to the gear train is a feedback control system which allows the motor to rotate the plug to predetermined locations for refueling of the reactor. The gear train contains a self locking double enveloping worm gear set. The worm gear set is utilized for its self locking nature to prevent unwanted rotation of the plugs as the result of an earthquake. The double enveloping type is used because its unique contour spreads the load across several teeth providing added strength and allowing the use of a conventional size worm.

  19. A Comparative Study of Cycle Variability of Laser Plug Ignition vs Classical Spark Plug Ignition in Combustion Engines

    NASA Astrophysics Data System (ADS)

    Done, Bogdan

    2017-10-01

    Over the past 30 years numerous studies and laboratory experiments have researched the use of laser energy to ignite gas and fuel-air mixtures. The actual implementation of this laser application has still to be fully achieved in a commercial automotive application. Laser Plug Ignition as a replacement for Spark Plug Ignition in the internal combustion engines of automotive vehicles, offers several potential benefits such as extending lean burn capability, reducing the cyclic variability between combustion cycles and decreasing the total amount of ignition costs, and implicitly weight and energy requirements. The paper presents preliminary results of cycle variability study carried on a SI Engine equipped with laser Plug Ignition system. Versus classic ignition system, the use of the laser Plug Ignition system assures the reduction of the combustion process variability, reflected in the lower values of the coefficient of variability evaluated for indicated mean effective pressure, maximum pressure, maximum pressure angle and maximum pressure rise rate. The laser plug ignition system was mounted on an experimental spark ignition engine and tested at the regime of 90% load and 2800 rev/min, at dosage of λ=1.1. Compared to conventional spark plug, laser ignition assures the efficiency at lean dosage.

  20. Friction Pull Plug Welding in Aluminum Alloys

    NASA Technical Reports Server (NTRS)

    Brooke, Shane A.; Bradford, Vann; Burkholder, Jonathon

    2011-01-01

    NASA fs Marshall Space Flight Center (MSFC) has recently invested much time and effort into the process development of Friction Pull Plug Welding (FPPW). FPPW, is a welding process similar to Friction Push Plug Welding in that, there is a small rotating part (plug) being spun and simultaneously pulled (forged) into a larger part. These two processes differ, in that push plug welding requires an internal reaction support, while pull plug welding reacts to the load externally. FPPW was originally conceived as a post proof repair technique for External Tank. FPPW was easily selected as the primary process used to close out the termination hole on the Constellation Program fs ARES I Upper Stage circumferential Self ] Reacting Friction Stir Welds (SR ]FSW). The versatility of FPPW allows it to also be used as a repair technique for both SR ]FSW and Conventional Friction Stir Welds. To date, all MSFC led development has been concentrated on aluminum alloys (2195, 2219, and 2014). Much work has been done to fully understand and characterize the process fs limitations. A heavy emphasis has been spent on plug design, to match the various weldland thicknesses and alloy combinations. This presentation will summarize these development efforts including weld parameter development, process control, parameter sensitivity studies, plug repair techniques, material properties including tensile, fracture and failure analysis.

  1. Friction Pull Plug Welding in Aluminum Alloys

    NASA Technical Reports Server (NTRS)

    Brooke, Shane A.; Bradford, Vann

    2012-01-01

    NASA's Marshall Space Flight Center (MSFC) has recently invested much time and effort into the process development of Friction Pull Plug Welding (FPPW). FPPW, is a welding process similar to Friction Push Plug Welding in that, there is a small rotating part (plug) being spun and simultaneously pulled (forged) into a larger part. These two processes differ, in that push plug welding requires an internal reaction support, while pull plug welding reacts to the load externally. FPPW was originally conceived as a post proof repair technique for the Space Shuttle fs External Tank. FPPW was easily selected as the primary weld process used to close out the termination hole on the Constellation Program's ARES I Upper Stage circumferential Self-Reacting Friction Stir Welds (SR-FSW). The versatility of FPPW allows it to also be used as a repair technique for both SR-FSW and Conventional Friction Stir Welds. To date, all MSFC led development has been concentrated on aluminum alloys (2195, 2219, and 2014). Much work has been done to fully understand and characterize the process's limitations. A heavy emphasis has been spent on plug design, to match the various weldland thicknesses and alloy combinations. This presentation will summarize these development efforts including weld parameter development, process control, parameter sensitivity studies, plug repair techniques, material properties including tensile, fracture and failure analysis.

  2. 33 CFR 183.556 - Plugs and fittings.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.556 Plugs and fittings. (a) A fuel system must not have a fitting for draining fuel. (b) A plug used to service the fuel...

  3. Fast-Acting Valve

    NASA Technical Reports Server (NTRS)

    Wojciechowski, Bogdan V. (Inventor); Pegg, Robert J. (Inventor)

    2003-01-01

    A fast-acting valve includes an annular valve seat that defines an annular valve orifice between the edges of the annular valve seat, an annular valve plug sized to cover the valve orifice when the valve is closed, and a valve-plug holder for moving the annular valve plug on and off the annular valve seat. The use of an annular orifice reduces the characteristic distance between the edges of the valve seat. Rather than this distance being equal to the diameter of the orifice, as it is for a conventional circular orifice, the characteristic distance equals the distance between the inner and outer radii (for a circular annulus). The reduced characteristic distance greatly reduces the gap required between the annular valve plug and the annular valve seat for the valve to be fully open, thereby greatly reducing the required stroke and corresponding speed and acceleration of the annular valve plug. The use of a valve-plug holder that is under independent control to move the annular valve plug between its open and closed positions is important for achieving controllable fast operation of the valve.

  4. Geologic controls on the formation of lakes in north-central Florida

    USGS Publications Warehouse

    Kindinger, Jack G.; Davis, Jeffrey B.; Flocks, James G.; Pitman, Janet K.; Carroll, Alan R.

    1998-01-01

    Fluid exchange between surficial waters and groundwater, as well as the processes that control this exchange, are of critical concern to water management districts and planners. Digital high-resolution seismic systems were used to collect geophysical data from 30 lakes of north-central Florida. Although using seismic profile data in the past has been less than successful, the use of digital technology has increased the potential for success. Seismic profiles collected from the lakes of north-central Florida have shown the potential application of these techniques in understanding the formation of individual lakes. In each case study, lake structure and geomorphology were controlled by solution and/or mechanical processes. Processes that control lake development are twofold: 1) karstification or dissolution of the underlying limestone, and 2) me collapse, subsidence, or slumping of overburden to form sinkholes. Initial lake formation is directly related to the karst topography of the underlying host limestone. Lake size and shape are a factor of the thickness of overburden and size of the collapse or subsidence and/or clustering of depressions allowing for lake development. Lake development is through progressive sequence stages to maturity that can be delineated into geomorphic types. Case studies have shown that lakes can be divided by geomorphic types into progressive developmental phases: (1) active subsidence or collapse phase (young) - the open to partially filled collapse structures typically associated with sink holes; (2) transitional phase (middle age) - the sinkhole is plugged as the voids within the collapse are filled with sediment, periodic reactivation may occur; (3) baselevel phase (mature) - active sinkholes are progressively plugged by the continual erosion of material into the basin, and eventually sediment fills the basins; and (4) polje (drowned prairie) - broad flat-bottom basins located within the epiphreatic zone that are inundated at high stages of the water table and have one or all phases of sinkhole development and many types of karst and karren features. Most lakes in this study have a small diameter (

  5. Spark Plug Defects and Tests

    NASA Technical Reports Server (NTRS)

    Silsbee, F B; Loeb, L B; Sawyer, L G; Fonseca, E L; Dickinson, H C; Agnew, P G

    1920-01-01

    The successful operation of the spark plug depends to a large extent on the gas tightness of the plug. Part 1 of this report describes the method used for measuring the gas tightness of aviation spark plugs. Part 2 describes the methods used in testing the electrical conductivity of the insulation material when hot. Part 3 describes the testing of the cold dielectric strength of the insulation material, the resistance to mechanical shock, and the final engine test.

  6. Flow plug with length-to-hole size uniformity for use in flow conditioning and flow metering

    NASA Technical Reports Server (NTRS)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor)

    2012-01-01

    A flow plug of varying thickness has a plurality of holes formed therethrough. The plug fits in a conduit such that a fluid flow in the conduit passes through the plug's holes. Each hole is defined by a parameter indicative of size in terms of the cross-sectional area thereof. A ratio of hole length-to-parameter is approximately the same for all of the holes.

  7. Small Intestinal Submucosa Plug for Closure of Dilated Nephrostomy Tracts: A Pilot Study in Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kakizawa, Hideyaki; Conlin, M. J.; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu

    2010-06-15

    The aim of this study was to evaluate efficacy of a plug made of small intestinal submucosa (SIS) for closure of dilated nephrostomy tract in the kidney after nephroscopy. Ten kidneys in 5 swine had nephrostomy tracts dilated up to 8 mm. The SIS plug was placed into the dilated renal cortex under nephroscopic control. Follow-up arteriograms, retrograde pyelograms, and macroscopic and histologic studies at 24 h (n = 4), 6 weeks (n = 2), and 3 months (n = 4) were performed to evaluate the efficacy of the plug. The SIS plug effectively closed the dilated nephrostomy tract. Follow-upmore » studies showed minimal changes of the kidneys, except for 1 small infarction, regarding inflammatory and foreign-body reactions and progressive scarring of the SIS. SIS plug is effective for occlusion of dilated nephrostomy tract after nephroscopy. Its efficacy should be compared with other therapeutic options.« less

  8. An ultra-stable optical frequency reference for space

    NASA Astrophysics Data System (ADS)

    Schuldt, T.; Döringshoff, K.; Kovalchuk, E.; Pahl, J.; Gohlke, M.; Weise, D.; Johann, U.; Peters, A.; Braxmaier, C.

    2017-11-01

    We realized ultra-stable optical frequency references on elegant breadboard (EBB) and engineering model (EM) level utilizing Doppler-free spectroscopy of molecular iodine near 532nm. A frequency stability of about 1•10-14 at an integration time of 1 s and below 5•10-15 at integration times between 10 s and 100 s was achieved. These values are comparable to the currently best laboratory setups. Both setups use a baseplate made of glass material where the optical components are joint using a specific assembly-integration technology. Compared to the EBB setup, the EM setup is further developed with respect to compactness and mechanical and thermal stability. The EM setup uses a baseplate made of fused silica with dimensions of 380 x 180 x 40 mm3 and a specifically designed 100 x 100 x 30 mm3 rectangular iodine cell in nine-pass configuration with a specific robust cold finger design. The EM setup was subjected to thermal cycling and vibrational testing. Applications of such an optical frequency reference in space can be found in fundamental physics, geoscience, Earth observation, and navigation & ranging. One example is the proposed mSTAR (mini SpaceTime Asymmetry Research) mission, dedicated to perform a Kennedy-Thorndike experiment on a satellite in a sunsynchronous low-Earth orbit. By comparing an iodine standard to a cavity-based frequency reference and integration over 2 year mission lifetime, the Kennedy-Thorndike coefficient will be determined with up to two orders of magnitude higher accuracy than the current best ground experiment. In a current study, the compatibility of the payload with the SaudiSat-4 host vehicle is investigated.

  9. Picometre and nanoradian heterodyne interferometry and its application in dilatometry and surface metrology

    NASA Astrophysics Data System (ADS)

    Schuldt, T.; Gohlke, M.; Kögel, H.; Spannagel, R.; Peters, A.; Johann, U.; Weise, D.; Braxmaier, C.

    2012-05-01

    A high-sensitivity heterodyne interferometer implementing differential wavefront sensing for tilt measurement was developed over the last few years. With this setup, using an aluminium breadboard and compact optical mounts with a beam height of 2 cm, noise levels less than 5 pm Hz-1/2 in translation and less than 10 nrad Hz-1/2 in tilt measurement, both for frequencies above 10-2 Hz, have been demonstrated. Here, a new, compact and ruggedized interferometer setup utilizing a baseplate made of Zerodur, a thermally and mechanically highly stable glass ceramic with a coefficient of thermal expansion (CTE) of 2 × 10-8 K-1, is presented. The optical components are fixed to the baseplate using a specifically developed, easy-to-handle, assembly-integration technology based on a space-qualified two-component epoxy. While developed as a prototype for future applications aboard satellite space missions (such as Laser Interferometer Space Antenna), the interferometer is used in laboratory experiments for dilatometry and surface metrology. A first dilatometer setup with a demonstrated accuracy of 10-7 K-1 in CTE measurement was realized. As it was seen that the accuracy is limited by the dimensional stability of the sample tube support, a new setup was developed utilizing Zerodur as structural material for the sample tube support. In another activity, the interferometer is used for characterization of high-quality mirror surfaces at the picometre level and for high-accuracy two-dimensional surface characterization in a prototype for industrial applications. In this paper, the corresponding designs, their realizations and first measurements of both applications in dilatometry and surface metrology are presented.

  10. Scapular notching in reverse shoulder arthroplasty: validation of a computer impingement model.

    PubMed

    Roche, Christopher P; Marczuk, Yann; Wright, Thomas W; Flurin, Pierre-Henri; Grey, Sean G; Jones, Richard B; Routman, Howard D; Gilot, Gregory J; Zuckerman, Joseph D

    2013-01-01

    The purpose of this study is to validate a reverse shoulder computer impingement model and quantify the impact of implant position on scapular impingement by comparing it to that of a radiographic analysis of 256 patients who received the same prosthesis and were followed postoperatively for an average of 22.2 months. A geometric computer analysis quantified anterior and posterior scapular impingement as the humerus was internally and externally rotated at varying levels of abduction and adduction relative to a fixed scapula at defined glenoid implant positions. These impingement results were compared to radiographic study of 256 patients who were analyzed for notching, glenoid baseplate position, and glenosphere overhang. The computer model predicted no impingement at 0° humeral abduction in the scapular plane for the 38 mm, 42 mm, and 46 mm devices when the glenoid baseplate cage peg is positioned 18.6 mm, 20.4 mm, and 22.7 mm from the inferior glenoid rim (of the reamed glenoid) or when glenosphere overhang of 4.6 mm, 4.7 mm, and 4.5 mm was obtained with each size glenosphere, respectively. When compared to the radiographic analysis, the computer model correctly predicted impingement based upon glenoid base- plate position in 18 of 26 patients with scapular notching and based upon glenosphere overhang in 15 of 26 patients with scapular notching. Reverse shoulder implant positioning plays an important role in scapular notching. The results of this study demonstrate that the computer impingement model can effectively predict impingement based upon implant positioning in a majority of patients who developed scapular notching clinically. This computer analysis provides guidance to surgeons on implant positions that reduce scapular notching, a well-documented complication of reverse shoulder arthroplasty.

  11. Characterization of a ViI-like Phage Specific to Escherichia coli O157:H7

    PubMed Central

    2011-01-01

    Phage vB_EcoM_CBA120 (CBA120), isolated against Escherichia coli O157:H7 from a cattle feedlot, is morphologically very similar to the classic phage ViI of Salmonella enterica serovar Typhi. Until recently, little was known genetically or physiologically about the ViI-like phages, and none targeting E. coli have been described in the literature. The genome of CBA120 has been fully sequenced and is highly similar to those of both ViI and the Shigella phage AG3. The core set of structural and replication-related proteins of CBA120 are homologous to those from T-even phages, but generally are more closely related to those from T4-like phages of Vibrio, Aeromonas and cyanobacteria than those of the Enterobacteriaceae. The baseplate and method of adhesion to the host are, however, very different from those of either T4 or the cyanophages. None of the outer baseplate proteins are conserved. Instead of T4's long and short tail fibers, CBA120, like ViI, encodes tail spikes related to those normally seen on podoviruses. The 158 kb genome, like that of T4, is circularly permuted and terminally redundant, but unlike T4 CBA120 does not substitute hmdCyt for cytosine in its DNA. However, in contrast to other coliphages, CBA120 and related coliphages we have isolated cannot incorporate 3H-thymidine (3H-dThd) into their DNA. Protein sequence comparisons cluster the putative "thymidylate synthase" of CBA120, ViI and AG3 much more closely with those of Delftia phage φW-14, Bacillus subtilis phage SPO1, and Pseudomonas phage YuA, all known to produce and incorporate hydroxymethyluracil (hmdUra). PMID:21899740

  12. Exposing the Secrets of Two Well-Known Lactobacillus casei Phages, J-1 and PL-1, by Genomic and Structural Analysis

    PubMed Central

    Dieterle, Maria Eugenia; Bowman, Charles; Batthyany, Carlos; Lanzarotti, Esteban; Turjanski, Adrián; Hatfull, Graham

    2014-01-01

    Bacteriophage J-1 was isolated in 1965 from an abnormal fermentation of Yakult using Lactobacillus casei strain Shirota, and a related phage, PL-1, was subsequently recovered from a strain resistant to J-1. Complete genome sequencing shows that J-1 and PL-1 are almost identical, but PL-1 has a deletion of 1.9 kbp relative to J-1, resulting in the loss of four predicted gene products involved in immunity regulation. The structural proteins were identified by mass spectrometry analysis. Similarly to phage A2, two capsid proteins are generated by a translational frameshift and undergo proteolytic processing. The structure of gene product 16 (gp16), a putative tail protein, was modeled based on the crystal structure of baseplate distal tail proteins (Dit) that form the baseplate hub in other Siphoviridae. However, two regions of the C terminus of gp16 could not be modeled using this template. The first region accounts for the differences between J-1 and PL-1 gp16 and showed sequence similarity to carbohydrate-binding modules (CBMs). J-1 and PL-1 GFP-gp16 fusions bind specifically to Lactobacillus casei/paracasei cells, and the addition of l-rhamnose inhibits binding. J-1 gp16 exhibited a higher affinity than PL-1 gp16 for cell walls of L. casei ATCC 27139 in phage adsorption inhibition assays, in agreement with differential adsorption kinetics observed for both phages in this strain. The data presented here provide insights into how Lactobacillus phages interact with their hosts at the first steps of infection. PMID:25217012

  13. An observational cohort study on persistency of internal teat sealant residues in milk after calving in dairy cows.

    PubMed

    Kabera, Fidèle; Dufour, Simon; Keefe, Greg; Roy, Jean-Philippe

    2018-04-04

    Our objectives were to evaluate the prevalence of quarters with an observable internal teat sealant (ITS) plug at first milking following calving and investigate persistency of ITS residues in milk after calving. An observational cohort study was carried out on 557 quarters of 156 cows treated with ITS in 6 farms in Quebec, Canada. The presence of an ITS plug at first milking and ITS residues in milk at each milking were observed by producers. The effects of various factors on the odds of observing an ITS plug and persistency of ITS residues in milk were studied using generalized logistic mixed and generalized negative binomial mixed models, respectively. Milk samples were taken on the day before dry-off and on 2 occasions after calving for bacterial identification to detect intramammary infection (IMI) using bacteriological culture followed by MALDI-TOF identification. The association between the absence of an ITS plug and the presence of new IMI was assessed using a mixed logistic regression model. Internal teat sealant plugs after calving were more often observed in rear quarters and in quarters receiving ITS alone at drying-off versus antimicrobial and ITS. We observed an average (standard deviation) persistency of 4.0 d (2.3 d). When an ITS plug was still present at first milking (83% of quarters), the elimination of ITS residues in milk after calving was significantly longer (4.5 d, on average) compared with 1.2 d when an ITS plug was absent. In cows with an ITS plug at calving, we observed a higher number of days of excretion in older cows. When a plug could not be observed, rear quarters, older cows, and cows with a long dry period duration excreted ITS residues for a significantly longer period. The lack of a significant association between the absence of a plug and the odds of new IMI at calving suggests that despite the loss of the plug, cows were still protected against new IMI. Although we were able to highlight some statistically significant risk factors explaining persistency of ITS residues following calving, observed differences were often relatively small and, perhaps, not clinically relevant. In conclusion, an ITS plug was present until first milking after calving for 83% quarters, quarters without an ITS plug at first milking appeared to have been protected from new IMI, and ITS residues could be observed in milk up to 12 d in milk. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. Experimental investigation of shock-cell noise reduction for dual-stream nozzles in simulated flight

    NASA Technical Reports Server (NTRS)

    Janardan, B. A.; Yamamoto, K.; Majjigi, R. K.; Brausch, J. F.

    1984-01-01

    Six scale-model nozzles were tested in an anechoic facility to evauate the effectiveness of convergent-divergent (C-D) terminations in reducing shock-cell noise of unsuppressed and mechanically suppressed coannular plug nozzles. One hundred fifty-three acoustic test points with inverted velocity profiles were conducted under static and simulated flight conditions. Diagnostic flow visualization with a shadowgraph and velocity measurements with a laser velocimeter were performed on selected plumes. Shock-cells were identified on the plug and downstream of the plug of the unsuppressed convergent coannular nozzle with truncated plug. Broadband peak frequencies predicted with the two shock-cell structures were correlated with the observed spectra using the measured shock-cell spacings. Relative to a convergent circular nozzle, the perceived noise level (PNL) data at an observer angle of 60 deg relative to inlet, indicated a reduction of (1) 6.5 dB and 9.2 dB with unsuppressed C-D coannular nozzle with truncated plug and (2) 7.7 dB and 8.3 dB with suppressed C-D coannular nozzle under static and simulated flight conditions, espectively. The unsuppressed C-D coannular nozzle with truncated plug, operating at the C-D design condition, had shock-cells downstream of the plug with no shock-cells on the plug. The downstream shock-cells were eliminated by replacing the truncated plug with a smooth extension to obtain an additional 2.4 dB and 3 dB front quadrant PNL reduction, under static and simulated flight conditions, respectively. Other results are discussed.

  15. Lithosphere-to-Ionosphere Plug-and-Play Architecture (LION-PNP): Networking the Physical World Made Cheap and Easy

    NASA Astrophysics Data System (ADS)

    Darling, N. T.; Mendez, J. S.; Fritz, T. A.; Hoffman, C.

    2012-12-01

    The lack of rapidly reconfigurable and easily deployable instrumentation packages often results in information loss during unannounced or time-critical geophysical events such as spaceweather flare-ups, earthquakes, volcanic eruptions, and tsunamis. While increasingly powerful and sensitive sensor technologies have been created in the last years to study our planet, robust, yet simple and cost-effective, mechanical, electrical, and data interfaces between these devices and the user (scientist) have yet to be developed. Non-standardized interfaces make instrument integration and field operation cumbersome and error-prone. Indeed, the assembly and deployment of some systems can take months and incur high costs. To address this problem, we present the LIthosphere-to-IOnosphere Plug-aNd-Play architecture (LION-PNP), a complete, low cost integration protocol for space, atmospheric, and terrestrial sensor networks. Similar to the USB plug-and-play protocols created for personal computers, LION-PNP offers geophysicists and space scientists the ability to assemble and operate complex sensor packages by simply "plugging" devices (magnetometers, seismometers, GPS, spectrometers, etc) into a centralized Command and Data Handling unit (CDH). LION-PNP accomplishes this by inserting a Generic Sensor Interpreter (GSI) between the back-end of a device and the CDH. The GSI allows the CDH to automatically configure a sensor without requiring the user to manually install drivers. Mechanical integration is also accelerated by repackaging instruments according to the CubeSAT form-factor (multiples of 10 x 10 x 10 cm cubes). In the following work, we report on the development of LION-PNP. To demonstrate our initial success, we first discuss the Boston University Student-satellite for Applications and Training (BUSAT), a low-cost, modular, spaceweather satellite running LION-PNP. BUSAT is a completely student-driven project meant for magnetospheric-ionospheric research incorporating 4 scientific payloads. To further stress the broad applicability of LION-PNP we also present VolcanoNET, a ground-based, multi-sensor package that will explore charging of volcanic ash plumes and volcanic lightning.; The Boston University Student satellite for Applications and Training (BUSAT) canisterized scientific satellite concept.

  16. Dual Spark Plugs For Stratified-Charge Rotary Engine

    NASA Technical Reports Server (NTRS)

    Abraham, John; Bracco, Frediano V.

    1996-01-01

    Fuel efficiency of stratified-charge, rotary, internal-combustion engine increased by improved design featuring dual spark plugs. Second spark plug ignites fuel on upstream side of main fuel injector; enabling faster burning and more nearly complete utilization of fuel.

  17. Bellows sealed plug valve

    DOEpatents

    Dukas, Jr., Stephen J.

    1990-01-01

    A bellows sealed plug valve includes a valve body having an inlet passage and an outlet passage, a valve chamber between the inlet and outlet passages. A valve plug has substantially the same shape as the valve chamber and is rotatably disposed therein. A shaft is movable linearly in response to a signal from a valve actuator. A bellows is sealingly disposed between the valve chamber and the valve actuator and means are located between the bellows and the valve plug for converting linear movement of the shaft connected to the valve actuator to rotational movement of the plug. Various means are disclosed including helical thread mechanism, clevis mechanism and rack and pinion mechanism, all for converting linear motion to rotational motion.

  18. Friction plug welding

    NASA Technical Reports Server (NTRS)

    Takeshita, Riki (Inventor); Hibbard, Terry L. (Inventor)

    2001-01-01

    Friction plug welding (FPW) usage is advantageous for friction stir welding (FSW) hole close-outs and weld repairs in 2195 Al--Cu--Li fusion or friction stir welds. Current fusion welding methods of Al--Cu--Li have produced welds containing varied defects. These areas are found by non-destructive examination both after welding and after proof testing. Current techniques for repairing typically small (<0.25) defects weaken the weldment, rely heavily on welders' skill, and are costly. Friction plug welding repairs increase strength, ductility and resistance to cracking over initial weld quality, without requiring much time or operator skill. Friction plug welding while pulling the plug is advantageous because all hardware for performing the weld can be placed on one side of the workpiece.

  19. Exhaust Nozzles for Supersonic Flight with Turbojet Engines

    NASA Technical Reports Server (NTRS)

    Shillito, Thomas B.; Hearth, Donald P.; Cortright, Edgar M.

    1956-01-01

    Good internal performance over a wide range of flight conditions can be obtained with either a plug nozzle or a variable ejector nozzle that can provide a divergent shroud at high pressure ratios. For both the ejector and the plug nozzle, external flow can sometimes cause serious drag losses and, for some plug-nozzle installations, external flow can cause serious internal performance losses. Plug-nozzle cooling and design of the secondary-air-flow systems for ejectors were also considered .

  20. Plug-in nanoliter pneumatic liquid dispenser with nozzle design flexibility

    PubMed Central

    Choi, In Ho; Kim, Hojin; Lee, Sanghyun; Baek, Seungbum; Kim, Joonwon

    2015-01-01

    This paper presents a novel plug-in nanoliter liquid dispensing system with a plug-and-play interface for simple and reversible, yet robust integration of the dispenser. A plug-in type dispenser was developed to facilitate assembly and disassembly with an actuating part through efficient modularization. The entire process for assembly and operation of the plug-in dispenser is performed via the plug-and-play interface in less than a minute without loss of dispensing quality. The minimum volume of droplets pneumatically dispensed using the plug-in dispenser was 124 nl with a coefficient of variation of 1.6%. The dispensed volume increased linearly with the nozzle size. Utilizing this linear relationship, two types of multinozzle dispensers consisting of six parallel channels (emerging from an inlet) and six nozzles were developed to demonstrate a novel strategy for volume gradient dispensing at a single operating condition. The droplet volume dispensed from each nozzle also increased linearly with nozzle size, demonstrating that nozzle size is a dominant factor on dispensed volume, even for multinozzle dispensing. Therefore, the proposed plug-in dispenser enables flexible design of nozzles and reversible integration to dispense droplets with different volumes, depending on the application. Furthermore, to demonstrate the practicality of the proposed dispensing system, we developed a pencil-type dispensing system as an alternative to a conventional pipette for rapid and reliable dispensing of minute volume droplets. PMID:26594263

  1. Acidic and basic solutions dissolve protein plugs made of lithostathine complicating choledochal cyst/pancreaticobiliary maljunction.

    PubMed

    Kaneko, Kenitiro; Ono, Yasuyuki; Tainaka, Takahisa; Sumida, Wataru; Ando, Hisami

    2009-07-01

    Symptoms of choledochal cysts are caused by protein plugs made of lithostathine, which block the long common channel and increase pancreaticobiliary ductal pressure. Agents that dissolve protein plugs can provide relief from or prevent symptoms. In the present study, drugs reportedly effective for pancreatic and biliary stones were used in dissolution tests. Protein plugs were obtained from choledochal cysts during surgery in two children (5- and 6-year-old girls). Plugs approximately 2 mm in diameter were immersed in citric acid, tartaric acid, dimethadione, bromhexine, dehydrocholic acid, sodium citrate, hydrochloric acid, and sodium hydroxide solutions under observation with a digital microscope. The pH of each solution was measured using a pH meter. Plugs dissolved in citric acid (5.2 mM; pH 2.64), tartaric acid (6.7 mM; pH 2.51), dimethadione (75 mM; pH 3.70), hydrochloric acid (0.5 mM; pH 3.13), and sodium hydroxide (75 mM; pH 12.75) solutions. Plugs did not dissolve in dimethadione (7.5 mM; pH 4.31), bromhexine (0.1%; pH 4.68), dehydrocholic acid (5%; pH 7.45), and sodium citrate (75 mM; pH 7.23) solutions. Protein plugs in choledochal cysts are dissolved in acidic and basic solutions, which may eliminate longitudinal electrostatic interactions of the lithostathine protofibrils.

  2. NASA SLS Booster Nozzle Plug Pieces Fly During Test

    NASA Image and Video Library

    2016-06-28

    On June 28, a test version of the booster that will help power NASA's new rocket, the Space Launch System, fired up at nearly 6,000 degrees Fahrenheit for a successful, two-minute qualification test at Orbital ATK's test facilities in Promontory, Utah. This video shows the booster's nozzle plug intentionally breaking apart. The smoky ring coming off the booster is condensed water vapor created by a pressure difference between the motor gas and normal air. The nozzle plug is an environmental barrier to prevent heat, dust and moisture from getting inside the booster before it ignites. The plug isn't always part of a static test but was included on this one due to changes made to the hardware. The foam on the plug is denser than previous NASA launch vehicles, as the engines are now in the same plane as the boosters. A numbered grid was placed on the exterior of the plug before the test so the pieces retrieved could support plug breakup assessment and reconstruction. Along with video, collecting the pieces helps determine the size and speed of them when they break apart. Nozzle plug pieces were found as far as 1,500 to 2,000 feet away from the booster. This is the last full-scale qualification test for the booster before the first, uncrewed flight of SLS with the Orion spacecraft in 2018.

  3. Plug-in nanoliter pneumatic liquid dispenser with nozzle design flexibility.

    PubMed

    Choi, In Ho; Kim, Hojin; Lee, Sanghyun; Baek, Seungbum; Kim, Joonwon

    2015-11-01

    This paper presents a novel plug-in nanoliter liquid dispensing system with a plug-and-play interface for simple and reversible, yet robust integration of the dispenser. A plug-in type dispenser was developed to facilitate assembly and disassembly with an actuating part through efficient modularization. The entire process for assembly and operation of the plug-in dispenser is performed via the plug-and-play interface in less than a minute without loss of dispensing quality. The minimum volume of droplets pneumatically dispensed using the plug-in dispenser was 124 nl with a coefficient of variation of 1.6%. The dispensed volume increased linearly with the nozzle size. Utilizing this linear relationship, two types of multinozzle dispensers consisting of six parallel channels (emerging from an inlet) and six nozzles were developed to demonstrate a novel strategy for volume gradient dispensing at a single operating condition. The droplet volume dispensed from each nozzle also increased linearly with nozzle size, demonstrating that nozzle size is a dominant factor on dispensed volume, even for multinozzle dispensing. Therefore, the proposed plug-in dispenser enables flexible design of nozzles and reversible integration to dispense droplets with different volumes, depending on the application. Furthermore, to demonstrate the practicality of the proposed dispensing system, we developed a pencil-type dispensing system as an alternative to a conventional pipette for rapid and reliable dispensing of minute volume droplets.

  4. Gastric varices and hepatic encephalopathy: treatment with vascular plug and gelatin sponge-assisted retrograde transvenous obliteration--a primary report.

    PubMed

    Gwon, Dong Il; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Kim, Jin Hyoung; Shin, Ji Hoon; Ko, Heung Kyu; Song, Ho-Young

    2013-07-01

    To evaluate technical safety, clinical safety, and effectiveness of vascular plug-assisted retrograde transvenous obliteration (RTO) for treatment of gastric varices (GV) and hepatic encephalopathy (HE). This retrospective study was approved by the institutional review board; written informed consent was waived. From April 2009 to December 2011, 20 patients (13, GV; seven, HE) who had undergone vascular plug-assisted RTO were retrospectively evaluated. After retrograde transvenous placement of a vascular plug in the left adrenal vein or gastrorenal shunt, subsequent gelatin-sponge embolization of both gastrorenal shunt and GV was performed. Follow-up computed tomography (CT) and upper gastrointestinal tract endoscopy were performed; clinical and laboratory data were collected to evaluate primary (technical success, complications, clinical success) and secondary (change of liver function by using the Child-Pugh score, worsening of esophageal varices) end points. Laboratory data before and after vascular plug-assisted RTO were compared (paired-sample t test). Placement of the vascular plug and subsequent gelatin-sponge embolization were technically successful in all 20 patients, with no procedure-related complications. Follow-up CT within 1 week after vascular plug-assisted RTO showed complete thrombosis of GV and gastrorenal shunts in all patients. Clinical symptoms of HE completely resolved in all seven patients with HE; mean serum NH3 level of 127.4 μmol/L ± 58 (standard deviation) before vascular plug-assisted RTO decreased significantly to 28.1 μmol/L ± 9.8 within 1 week after vascular plug-assisted RTO (P = .002). Eighteen patients who underwent follow-up longer than 2 months showed complete obliteration of GV and gastrorenal shunts at CT and endoscopy. There were no cases of variceal bleeding or HE during mean follow-up of 422 days. Improvement in Child-Pugh score was observed in 12 of 18 (67%) patients 1 month after vascular plug-assisted RTO. Worsening of esophageal varices was observed in four (22%) patients at mean follow-up of 9.4 months. Vascular plug-assisted RTO is technically simple and safe and seems to be clinically effective for treatment of GV and HE.

  5. Parallel Eclipse Project Checkout

    NASA Technical Reports Server (NTRS)

    Crockett, Thomas M.; Joswig, Joseph C.; Shams, Khawaja S.; Powell, Mark W.; Bachmann, Andrew G.

    2011-01-01

    Parallel Eclipse Project Checkout (PEPC) is a program written to leverage parallelism and to automate the checkout process of plug-ins created in Eclipse RCP (Rich Client Platform). Eclipse plug-ins can be aggregated in a feature project. This innovation digests a feature description (xml file) and automatically checks out all of the plug-ins listed in the feature. This resolves the issue of manually checking out each plug-in required to work on the project. To minimize the amount of time necessary to checkout the plug-ins, this program makes the plug-in checkouts parallel. After parsing the feature, a request to checkout for each plug-in in the feature has been inserted. These requests are handled by a thread pool with a configurable number of threads. By checking out the plug-ins in parallel, the checkout process is streamlined before getting started on the project. For instance, projects that took 30 minutes to checkout now take less than 5 minutes. The effect is especially clear on a Mac, which has a network monitor displaying the bandwidth use. When running the client from a developer s home, the checkout process now saturates the bandwidth in order to get all the plug-ins checked out as fast as possible. For comparison, a checkout process that ranged from 8-200 Kbps from a developer s home is now able to saturate a pipe of 1.3 Mbps, resulting in significantly faster checkouts. Eclipse IDE (integrated development environment) tries to build a project as soon as it is downloaded. As part of another optimization, this innovation programmatically tells Eclipse to stop building while checkouts are happening, which dramatically reduces lock contention and enables plug-ins to continue downloading until all of them finish. Furthermore, the software re-enables automatic building, and forces Eclipse to do a clean build once it finishes checking out all of the plug-ins. This software is fully generic and does not contain any NASA-specific code. It can be applied to any Eclipse-based repository with a similar structure. It also can apply build parameters and preferences automatically at the end of the checkout.

  6. Mating Plugs in Polyandrous Giants: Which Sex Produces Them, When, How and Why?

    PubMed Central

    Kuntner, Matjaž; Kralj-Fišer, Simona; Li, Daiqin

    2012-01-01

    Background Males usually produce mating plugs to reduce sperm competition. However, females can conceivably also produce mating plugs in order to prevent unwanted, superfluous and energetically costly matings. In spiders–appropriate models for testing plugging biology hypotheses–mating plugs may consist of male genital parts and/or of amorphous covers consisting of glandular or sperm secretions. In the giant wood spider Nephila pilipes, a highly sexually dimorphic and polygamous species, males are known to produce ineffective embolic plugs through genital damage, but nothing is known about the origin and function of additional conspicuous amorphous plugs (AP) covering female genitals. Methodology We tested alternative hypotheses of the nature and function of AP in N. pilipes by staging mating trials with varying degrees of polyandry. No APs were ever formed during mating trials, which rules out the possibility of male AP formation. Instead, those females that oviposited produced the AP from a liquid secreted during egg sac formation. Polyandrous females were more likely to lay eggs and to produce the AP, as were those that mated longer and with more total insertions. Our further tests revealed that, in spite of being a side product of egg sac production, AP, when hardened, prevented any subsequent copulation. Conclusions We conclude that in the giant wood spider (Nephila pilipes), the amorphous mating plugs are not produced by the males, that repeated copulations (most likely polyandrous) are necessary for egg fertilization and AP formation, and that the AP represents a female adaptation to sexual conflict through prevention of unwanted, excessive copulations. Considering the largely unknown origin of amorphous plugs in spiders, we predict that a similar pattern might be detected in other clades, which would help elucidate the evolutionary interplay of various selection pressures responsible for the origin and maintenance of mating plugs. PMID:22829900

  7. The cervical mucus plug inhibits, but does not block, the passage of ascending bacteria from the vagina during pregnancy.

    PubMed

    Hansen, Lea K; Becher, Naja; Bastholm, Sara; Glavind, Julie; Ramsing, Mette; Kim, Chong J; Romero, Roberto; Jensen, Jørgen S; Uldbjerg, Niels

    2014-01-01

    To evaluate the microbial load and the inflammatory response in the distal and proximal parts of the cervical mucus plug. Experimental research. Twenty women with a normal, singleton pregnancy. Vaginal swabs and specimens from the distal and proximal parts of the cervical mucus plug. Immunohistochemistry, enzyme-linked immunosorbent assay, quantitative polymerase chain reaction and histology. The total bacterial load (16S rDNA) was significantly lower in the cervical mucus plug compared with the vagina (p = 0.001). Among women harboring Ureaplasma parvum, the median genome equivalents/g were 1574 (interquartile range 2526) in the proximal part, 657 (interquartile range 1620) in the distal part and 60,240 (interquartile range 96,386) in the vagina. Histological examinations and quantitative polymerase chain reaction revealed considerable amounts of lactobacilli and inflammatory cells in both parts of the cervical mucus plug. The matrix metalloproteinase-8 concentration was decreased in the proximal part of the plug compared with the distal part (p = 0.08). The cervical mucus plug inhibits, but does not block, the passage of Ureaplasma parvum during its ascending route from the vagina through the cervical canal. © 2013 Nordic Federation of Societies of Obstetrics and Gynecology.

  8. Fail-Safe Pressure Plug

    NASA Technical Reports Server (NTRS)

    Svejkovsky, Paul A.

    1993-01-01

    Protective plug resists slowly built-up pressure or automatically releases itself if pressure rises suddenly. Seals out moisture at pressures ranging from 50 micrometers of mercury to 200 pounds per square inch. Designed to seal throat of 38 Reaction Control Thrusters on Space Shuttle protecting internal components from corrosion. Plug conforms to contour of nozzle throat, where O-ring forms pressure seal. After plug inserted, cover attached by use of cover-fitting assembly. Modified versions useful in protecting engines, pumps, reaction vessels, and other industrial equipment during shipment and maintenance.

  9. Microscopic Evaluation of Friction Plug Welds- Correlation to a Processing Analysis

    NASA Technical Reports Server (NTRS)

    Rabenberg, Ellen M.; Chen, Poshou; Gorti, Sridhar

    2017-01-01

    Recently an analysis of dynamic forge load data from the friction plug weld (FPW) process and the corresponding tensile test results showed that good plug welds fit well within an analytically determined processing parameter box. There were, however, some outliers that compromised the predictions. Here the microstructure of the plug weld material is presented in view of the load analysis with the intent of further understanding the FPW process and how it is affected by the grain structure and subsequent mechanical properties.

  10. Plug-in electric vehicle market penetration and incentives: a global review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Yan; Wang, Michael; Hao, Han

    Plug-in electric vehicles (PEVs) have been commercially available in the global market for about 3 years. Many countries have policies designed to stimulate consumer acceptance and accelerate market adoption. In the United States (U.S.), the biggest PEV market, sales have more than tripled since 2011. During the same period, PEV sales have increased, albeit slowly, in most western European countries. Notably, some European countries, such as Norway, showed strong increases mainly owing to generous incentives to PEV consumers. Japan is the second-largest PEV market in terms of number of vehicles sold. The Nissan battery electric vehicle (BEV) Leaf is themore » top-selling PEV model, with more than 100,000 units sold globally since its launch in 2010. In contrast, after 3 years of policy stimulation, PEV market share in China is still lower than 0.1 % of total car sales, and most of these vehicles were purchased by either central or local governments. However, PEV bus production in China has increased dramatically over last 3 years. These market trends, together with strong government policies, show that national and regional PEV-related incentives in selected countries can play an important role in jump-starting the PEV market.« less

  11. Perforating collagenosis.

    PubMed

    Yancovitz, Molly; Johnson, Hillary; Wang, Nadia; Pomeranz, Miriam K

    2008-10-15

    A 55-year-old man presented with a three-week history of pruritic, erythematous papules with hyperkeratotic dells on the dorsum of the left hand, which was preceded by swelling, redness and itching. Histopathologic examination showed an acanthotic epidermis with a central invagination filled with a plug composed of parakeratotic debris, collagen, and inflammatory cells. These findings are consistent with acquired reactive perforating collagenosis, which is most frequently reported in patients with pruritus and underlying diabetes mellitus or chronic renal insufficiency. Topical and oral retinoids and topical and intralesional glucocorticoids have been reported to be effective in some patients in case series.

  12. Strain-induced extinction of hydrogen-air counterflow diffusion flames - Effects of steam, CO2, N2, and O2 additives to air

    NASA Technical Reports Server (NTRS)

    Pellett, G. L.; Northam, G. B.; Wilson, L. G.

    1992-01-01

    A fundamental study was performed using axisymmetric nozzle and tubular opposed jet burners to measure the effects of laminar plug flow and parabolic input velocity profiles on the extinction limits of H2-air counterflow diffusion flames. Extinction limits were quantified by 'flame strength', (average axial air jet velocity) at blowoff of the central flame. The effects of key air contaminants, on the extinction limits, are characterized and analyzed relative to utilization of combustion contaminated vitiated air in high enthalpy supersonic test facilities.

  13. Local plantar pressure relief in therapeutic footwear: design guidelines from finite element models.

    PubMed

    Erdemir, Ahmet; Saucerman, Jeffrey J; Lemmon, David; Loppnow, Bryan; Turso, Brie; Ulbrecht, Jan S; Cavanagh, Peter Re

    2005-09-01

    A major goal of therapeutic footwear in patients with pain or those at risk for skin injury is to relieve focal loading under prominent metatarsal heads. One frequent approach is to place plugs of compliant material into the midsole of the shoe. This study investigated 36 plug designs, a combination of three materials, six geometries, and two placements using a two-dimensional (2D) finite element model. Realistic loading conditions were obtained from plantar pressures (PP) recorded during walking in five subjects who wore control midsoles manufactured using Microcell Puff. Measured peak pressures underneath the second metatarsal head were similar to the results of the control model. PP obtained from simulations with the plugs built into a firm midsole were compared to the simulation results of the control midsole. Large plugs (e.g. 40 mm width), made out of Microcell Puff Lite or Plastazote Medium, placed at peak pressure sites, resulted in highest reductions in peak pressures (18-28%). Smaller plugs benefited from tapering when placed at high pressure areas. Case studies were completed on a healthy male subject and a diabetic female patient to address the efficacy of a plug design favored by our simulations (pressure based placement, 40 x 20 mm, Plastazote Medium). Successful reductions of second metatarsal head pressures were observed with a mediolateral load redistribution that was not represented by our model. 2D computer simulations allowed systematic investigation of plug properties without the need for high volume experimentation on human subjects and established basic guidelines for plug selection. In particular, plugs that are placed based on plantar pressure measurements were proven to be more effective when compared to those positioned according to the projection of the bony landmark on the foot-shoe plantar contact area.

  14. Coil-On-Plug Ignition for Oxygen/Methane Liquid Rocket Engines in Thermal-Vacuum Environments

    NASA Technical Reports Server (NTRS)

    Melcher, John C.; Atwell, Matthew J.; Morehead, Robert L.; Hurlbert, Eric A.; Bugarin, Luz; Chaidez, Mariana

    2017-01-01

    A coil-on-plug ignition system has been developed and tested for Liquid Oxygen (LOX)/liquid methane (LCH4) rocket engines operating in thermal vacuum conditions. The igniters were developed and tested as part of the Integrated Cryogenic Propulsion Test Article (ICPTA), previously tested as part of the Project Morpheus test vehicle. The ICPTA uses an integrated, pressure-fed, cryogenic LOX/LCH4 propulsion system including a reaction control system (RCS) and a main engine. The ICPTA was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. A coil-on-plug ignition system has been developed to successfully demonstrate ignition reliability at these conditions while preventing corona discharge issues. The ICPTA uses spark plug ignition for both the main engine igniter and the RCS. The coil-on-plug configuration eliminates the conventional high-voltage spark plug cable by combining the coil and the spark plug into a single component. Prior to ICPTA testing at Plum Brook, component-level reaction control engine (RCE) and main engine igniter testing was conducted at NASA Johnson Space Center (JSC), which demonstrated successful hot-fire ignition using the coil-on-plug from sea-level ambient conditions down to 10(exp -2) torr. Integrated vehicle hot-fire testing at JSC demonstrated electrical and command/data system performance. Lastly, hot-fire testing at Plum Brook demonstrated successful ignitions at simulated altitude conditions at 30 torr and cold thermal-vacuum conditions at 6 torr. The test campaign successfully proved that coil-on-plug technology will enable integrated LOX/LCH4 propulsion systems in future spacecraft.

  15. Coil-On-Plug Ignition for LOX/Methane Liquid Rocket Engines in Thermal Vacuum Environments

    NASA Technical Reports Server (NTRS)

    Melcher, John C.; Atwell, Matthew J.; Morehead, Robert L.; Hurlbert, Eric A.; Bugarin, Luz; Chaidez, Mariana

    2017-01-01

    A coil-on-plug ignition system has been developed and tested for Liquid Oxygen (LOX) / liquid methane rocket engines operating in thermal vacuum conditions. The igniters were developed and tested as part of the Integrated Cryogenic Propulsion Test Article (ICPTA), previously tested as part of the Project Morpheus test vehicle. The ICPTA uses an integrated, pressure-fed, cryogenic LOX/methane propulsion system including a reaction control system (RCS) and a main engine. The ICPTA was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. In order to successfully demonstrate ignition reliability in the vacuum conditions and eliminate corona discharge issues, a coil-on-plug ignition system has been developed. The ICPTA uses spark-plug ignition for both the main engine igniter and the RCS. The coil-on-plug configuration eliminates the conventional high-voltage spark plug cable by combining the coil and the spark-plug into a single component. Prior to ICPTA testing at Plum Brook, component-level reaction control engine (RCE) and main engine igniter testing was conducted at NASA Johnson Space Center (JSC), which demonstrated successful hot-fire ignition using the coil-on-plug from sea-level ambient conditions down to 10(exp.-2) torr. Integrated vehicle hot-fire testing at JSC demonstrated electrical and command/data system performance. Lastly, Plum Brook testing demonstrated successful ignitions at simulated altitude conditions at 30 torr and cold thermal-vacuum conditions at 6 torr. The test campaign successfully proved that coil-on-plug technology will enable integrated LOX/methane propulsion systems in future spacecraft.

  16. Automated microfluidic platform for studies of carbon dioxide dissolution and solubility in physical solvents.

    PubMed

    Abolhasani, Milad; Singh, Mayank; Kumacheva, Eugenia; Günther, Axel

    2012-05-07

    We present an automated microfluidic (MF) approach for the systematic and rapid investigation of carbon dioxide (CO(2)) mass transfer and solubility in physical solvents. Uniformly sized bubbles of CO(2) with lengths exceeding the width of the microchannel (plugs) were isothermally generated in a co-flowing physical solvent within a gas-impermeable, silicon-based MF platform that is compatible with a wide range of solvents, temperatures and pressures. We dynamically determined the volume reduction of the plugs from images that were accommodated within a single field of view, six different downstream locations of the microchannel at any given flow condition. Evaluating plug sizes in real time allowed our automated strategy to suitably select inlet pressures and solvent flow rates such that otherwise dynamically self-selecting parameters (e.g., the plug size, the solvent segment size, and the plug velocity) could be either kept constant or systematically altered. Specifically, if a constant slug length was imposed, the volumetric dissolution rate of CO(2) could be deduced from the measured rate of plug shrinkage. The solubility of CO(2) in the physical solvent was obtained from a comparison between the terminal and the initial plug sizes. Solubility data were acquired every 5 min and were within 2-5% accuracy as compared to literature data. A parameter space consisting of the plug length, solvent slug length and plug velocity at the microchannel inlet was established for different CO(2)-solvent pairs with high and low gas solubilities. In a case study, we selected the gas-liquid pair CO(2)-dimethyl carbonate (DMC) and volumetric mass transfer coefficients 4-30 s(-1) (translating into mass transfer times between 0.25 s and 0.03 s), and Henry's constants, within the range of 6-12 MPa.

  17. Preparation and Evaluation of Biodegradable Scleral Plug Containing Curcumin in Rabbit Eye.

    PubMed

    Zhang, Jun; Sun, Haiyan; Zhou, Nalei; Zhang, Bin; Ma, Jingxue

    2017-12-01

    To test whether biodegradable curcumin-loaded scleral plug is a promising choice for treating posterior ocular diseases, the study investigated the in vitro release profile of the scleral plug and its safety in vivo. Scleral plugs containing 0.5 mg, 1.0 mg and 1.5 mg curcumin were synthesized by a compression-sintering method. These scleral plugs were placed in tubes containing balanced salt solution (BSS) buffer, which was replaced by fresh buffer daily. The curcumin concentration in the removed aliquot was tested daily for 14 days using high-performance liquid chromatography (HPLC). In the study, 44 rabbits were randomly divided into four groups: control, 0.5 mg, 1.0 mg and 1.5 mg curcumin groups. The scleral plug was trans-scleral fixed in the right eye of the rabbits in the three curcumin-treated groups. The control rabbits only received sclerotomy. The treated rabbit eyes were examined by a slit-lamp biomicroscope, an indirect ophthalmoscope and electroretinogram (ERG), and subjected to histological analysis. The concentration of the 1.5 mg curcumin-loaded scleral plug was higher than 15 μg/ml for consecutive 14 days in vitro. The in vivo experiments revealed intraocular pressure, a-wave and b-wave amplitudes of ERG, and conjunctival reaction degree were not significantly different between the four groups. Retinal structure was normal in the curcumin-treated groups. The sclerotomy wound healed after the plug was completely degraded. Anterior chamber reaction or complications were not observed. The study suggests that curcumin-loaded scleral plug could sustain high concentration of curcumin in vitro and is safe in vivo. It might be a promising alternative choice for the treatment of posterior ocular diseases.

  18. Punctal plugs versus artificial tears for treating dry eye: a comparative observation of their effects on contrast sensitivity.

    PubMed

    Qiu, Weiqiang; Liu, Ziyuan; Zhang, Zhihong; Ao, Mingxin; Li, Xuemin; Wang, Wei

    2012-01-01

    This study aimed to compare the effects of treatment with punctal plugs versus artificial tears on visual function and tear film stability for dry eye. A total of 56 consecutive eyes of 28 dry eye patients observed at our clinic from May to October in 2009 were divided into two groups. One group (32 eyes of 16 patients) was treated with artificial tears, and punctal plugs were used in the other group (24 eyes of 12 patients). A questionnaire was used in these patients before treatment and was repeated 2 weeks after treatment. Fluorescent staining for tear film break-up time (BUT), the Schirmer test I (STI), and contrast sensitivity was performed at the same time. The questionnaire indicated that all patients complained about the uncomfortable symptoms associated with dry eye. These symptoms were relieved after the application of artificial tears or punctal plugs, and there was no significant difference between these two groups. We found that the corneal fluorescent staining disappeared after treatment. The BUT was improved significantly after treatment in both groups, but the improvement was greater in patients who received punctal plugs than those that received artificial tears. There was no remarkable change in the STI in the artificial tears group, but a significant change was observed in the punctal plugs group. The contrast sensitivities were greatly improved in simulated daylight, night, and glare disability conditions after treatment with artificial tears and punctal plugs. However, the changes in contrast sensitivity did not significantly differ between groups. Both artificial tears and punctal plugs relieved dry eye symptoms, repaired corneal lesions, enhanced tear film stability, and improved contrast sensitivity. Punctal plugs could improve tear film stability and elongate the BUT better than artificial tears.

  19. Porous plug for reducing orifice induced pressure error in airfoils

    NASA Technical Reports Server (NTRS)

    Plentovich, Elizabeth B. (Inventor); Gloss, Blair B. (Inventor); Eves, John W. (Inventor); Stack, John P. (Inventor)

    1988-01-01

    A porous plug is provided for the reduction or elimination of positive error caused by the orifice during static pressure measurements of airfoils. The porous plug is press fitted into the orifice, thereby preventing the error caused either by fluid flow turning into the exposed orifice or by the fluid flow stagnating at the downstream edge of the orifice. In addition, the porous plug is made flush with the outer surface of the airfoil, by filing and polishing, to provide a smooth surface which alleviates the error caused by imperfections in the orifice. The porous plug is preferably made of sintered metal, which allows air to pass through the pores, so that the static pressure measurements can be made by remote transducers.

  20. System and method for charging a plug-in electric vehicle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bassham, Marjorie A.; Spigno, Jr., Ciro A.; Muller, Brett T.

    2017-05-02

    A charging system and method that may be used to automatically apply customized charging settings to a plug-in electric vehicle, where application of the settings is based on the vehicle's location. According to an exemplary embodiment, a user may establish and save a separate charging profile with certain customized charging settings for each geographic location where they plan to charge their plug-in electric vehicle. Whenever the plug-in electric vehicle enters a new geographic area, the charging method may automatically apply the charging profile that corresponds to that area. Thus, the user does not have to manually change or manipulate themore » charging settings every time they charge the plug-in electric vehicle in a new location.« less

  1. Molten tin reprocessing of spent nuclear fuel elements

    DOEpatents

    Heckman, Richard A.

    1983-01-01

    A method and apparatus for reprocessing spent nuclear fuel is described. Within a containment vessel, a solid plug of tin and nitride precipitates supports a circulating bath of liquid tin therein. Spent nuclear fuel is immersed in the liquid tin under an atmosphere of nitrogen, resulting in the formation of nitride precipitates. The layer of liquid tin and nitride precipitates which interfaces the plug is solidified and integrated with the plug. Part of the plug is melted, removing nitride precipitates from the containment vessel, while a portion of the plug remains solidified to support the liquid tin and nitride precipitates remaining in the containment vessel. The process is practiced numerous times until substantially all of the precipitated nitrides are removed from the containment vessel.

  2. National Plug-In Electric Vehicle Infrastructure Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wood, Eric; Rames, Clement; Muratori, Matteo

    This report addresses the fundamental question of how much plug-in electric vehicle (PEV) charging infrastructure—also known as electric vehicle supply equipment (EVSE)—is needed in the United States to support both plug-in hybrid electric vehicles (PHEVs) and battery electric vehicles (BEVs).

  3. Nozzle dam having a unitary plug

    DOEpatents

    Veronesi, L.; Wepfer, R.M.

    1992-12-15

    Apparatus for sealing the primary-side coolant flow nozzles of a nuclear steam generator is disclosed. The steam generator has relatively small diameter manway openings for providing access to the interior of the steam generator including the inside surface of each nozzle, the manway openings having a diameter substantially less than the inside diameter of each nozzle. The apparatus includes a bracket having an outside surface for matingly sealingly engaging the inside surface of the nozzle. The bracket also has a plurality of openings longitudinally therethrough and a plurality of slots transversely therein in communication with each opening. A plurality of unitary plugs sized to pass through the manway opening are matingly sealingly disposed in each opening of the bracket for sealingly plugging each opening. Each plug includes a plurality of arms operable to engage the slots of the bracket for connecting each plug to the bracket, so that the nozzle is sealed as the plugs seal the openings and are connected to the bracket. 16 figs.

  4. Nozzle dam having a unitary plug

    DOEpatents

    Veronesi, Luciano; Wepfer, Robert M.

    1992-01-01

    Apparatus for sealing the primary-side coolant flow nozzles of a nuclear steam generator. The steam generator has relatively small diameter manway openings for providing access to the interior of the steam generator including the inside surface of each nozzle, the manway openings having a diameter substantially less than the inside diameter of each nozzle. The apparatus includes a bracket having an outside surface for matingly sealingly engaging the inside surface of the nozzle. The bracket also has a plurality of openings longitudinally therethrough and a plurality of slots transversely therein in communication with each opening. A plurality of unitary plugs sized to pass through the manway opening are matingly sealingly disposed in each opening of the bracket for sealingly plugging each opening. Each plug includes a plurality of arms operable to engage the slots of the bracket for connecting each plug to the bracket, so that the nozzle is sealed as the plugs seal the openings and are connected to the bracket.

  5. Stimulus learning and response learning by observation in the European starling, in a two-object/two-action test.

    PubMed

    Campbell; Heyes; Goldsmith

    1999-07-01

    Juvenile European starlings, Sturnus vulgaris, were allowed to observe a conspecific demonstrator using its beak to remove one of two distinctively coloured objects (i.e. a red or a black plug) from a hole in the lid of a plastic box. Both plugs could be removed by either pulling up on a loop of string inserted through the centre of the plug, or pushing down on the plug. When subsequently allowed access to the plugs, and rewarded with food for all removal responses, regardless of the object to which they were made and their direction, observer birds removed the same plug in the same direction as their demonstrator. These results suggest that the two-object/two-action paradigm is a valuable procedure for testing for the simultaneous effects of learning about a stimulus and a response, an object and an action, through conspecific observation. Copyright 1999 The Association for the Study of Animal Behaviour.

  6. 30 CFR 18.41 - Plug and receptacle-type connectors.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...

  7. 30 CFR 18.41 - Plug and receptacle-type connectors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...

  8. 30 CFR 18.41 - Plug and receptacle-type connectors.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...

  9. 30 CFR 18.41 - Plug and receptacle-type connectors.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...

  10. 30 CFR 18.41 - Plug and receptacle-type connectors.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...

  11. Intraocular foreign-body hazard during vitrectomy.

    PubMed

    Bovino, J A; Marcus, D F

    1982-03-01

    We noted two instances of forceps-induced fragmentation of the bar used for scleral plug storage during vitreous surgery. The silicone bar material was adherent to the plug in both cases. Because this represents a significant intraocular foreign body hazard, the scleral plug should be carefully inspected before insertion.

  12. Rotating plug bearing and seal

    DOEpatents

    Wade, Elman E.

    1977-01-01

    A bearing and seal structure for nuclear reactors utilizing rotating plugs above the nuclear reactor vessel. The structure permits lubrication of bearings and seals of the rotating plugs without risk of the lubricant draining into the reactor vessel below. The structure permits lubrication by utilizing a rotating outer race bearing.

  13. Dynamics of seismogenic volcanic extrusion resisted by a solid surface plug, Mount St. Helens, 2004-2005: Chapter 21 in A volcano rekindled: the renewed eruption of Mount St. Helens, 2004-2006

    USGS Publications Warehouse

    Iverson, Richard M.; Sherrod, David R.; Scott, William E.; Stauffer, Peter H.

    2008-01-01

    The 2004-5 eruption of Mount St. Helens exhibited sustained, near-equilibrium behavior characterized by nearly steady extrusion of a solid dacite plug and nearly periodic occurrence of shallow earthquakes. Diverse data support the hypothesis that these earthquakes resulted from stick-slip motion along the margins of the plug as it was forced incrementally upward by ascending, solidifying, gas-poor magma. I formalize this hypothesis with a mathematical model derived by assuming that magma enters the base of the eruption conduit at a steady rate, invoking conservation of mass and momentum of the magma and plug, and postulating simple constitutive equations that describe magma and conduit compressibilities and friction along the plug margins. Reduction of the model equations reveals a strong mathematical analogy between the dynamics of the magma-plug system and those of a variably damped oscillator. Oscillations in extrusion velocity result from the interaction of plug inertia, a variable upward force due to magma pressure, and a downward force due to the plug weight. Damping of oscillations depends mostly on plug-boundary friction, and oscillations grow unstably if friction exhibits rate weakening similar to that observed in experiments. When growth of oscillations causes the extrusion rate to reach zero, however, gravity causes friction to reverse direction, and this reversal instigates a transition from unstable oscillations to self-regulating stick-slip cycles. The transition occurs irrespective of the details of rate-weakening behavior, and repetitive stick-slip cycles are, therefore, robust features of the system’s dynamics. The presence of a highly compressible elastic driving element (that is, magma containing bubbles) appears crucial for enabling seismogenic slip events to occur repeatedly at the shallow earthquake focal depths (8 N. These results imply that the system’s self-regulating behavior is not susceptible to dramatic change--provided that the rate of magma ascent remains similar to the rate of magma accretion at the base of the plug, that plug surface erosion more or less compensates for mass gain due to basal accretion, and that magma and rock properties do not change significantly. Even if disequilibrium initial conditions are imposed, the dynamics of the magma-plug system are strongly attracted to self-regulating stick-slip cycles, although this self-regulating behavior can be bypassed on the way to runaway behavior if the initial state is too far from equilibrium.

  14. 21 CFR 886.4155 - Scleral plug.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... stainless steel with or without a gold, silver, or titanium coating. The special controls for the surgical grade stainless steel scleral plug (with or without a gold, silver, or titanium coating) are: (i) The... titanium coating). The special controls for scleral plugs made of other materials are: (i) The device must...

  15. 78 FR 70395 - Buy America Waiver Notification

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-25

    ...--light, medium, and heavy duty plug-in battery electric and compressed natural gas vehicles by Chicago..., medium, and heavy duty plug-in battery electric and compressed natural gas vehicles by Chicago DOT. In...--light, medium, and heavy duty plug-in battery electric and compressed natural gas vehicles ( http://www...

  16. Excess flow shutoff valve

    DOEpatents

    Kiffer, Micah S.; Tentarelli, Stephen Clyde

    2016-02-09

    Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.

  17. Nuclear reactor apparatus

    DOEpatents

    Wade, Elman E.

    1978-01-01

    A lifting, rotating and sealing apparatus for nuclear reactors utilizing rotating plugs above the nuclear reactor core. This apparatus permits rotation of the plugs to provide under the plug refueling of a nuclear core. It also provides a means by which positive top core holddown can be utilized. Both of these operations are accomplished by means of the apparatus lifting the top core holddown structure off the nuclear core while stationary, and maintaining this structure in its elevated position during plug rotation. During both of these operations, the interface between the rotating member and its supporting member is sealingly maintained.

  18. Low power integrated pumping and valving arrays for microfluidic systems

    DOEpatents

    Krulevitch, Peter A [Pleasanton, CA; Benett, William J [Livermore, CA; Rose, Klint A [Livermore, CA; Hamilton, Julie [Tracy, CA; Maghribi, Mariam [Davis, CA

    2006-04-11

    Low power integrated pumping and valving arrays which provide a revolutionary approach for performing pumping and valving approach for performing pumping and valving operations in microfabricated fluidic systems for applications such as medical diagnostic microchips. Traditional methods rely on external, large pressure sources that defeat the advantages of miniaturization. Previously demonstrated microfabrication devices are power and voltage intensive, only function at sufficient pressure to be broadly applicable. This approach integrates a lower power, high-pressure source with a polymer, ceramic, or metal plug enclosed within a microchannel, analogous to a microsyringe. When the pressure source is activated, the polymer plug slides within the microchannel, pumping the fluid on the opposite side of the plug without allowing fluid to leak around the plug. The plugs also can serve as microvalves.

  19. Molten tin reprocessing of spent nuclear fuel elements. [Patent application; continuous process

    DOEpatents

    Heckman, R.A.

    1980-12-19

    A method and apparatus for reprocessing spent nuclear fuel is described. Within a containment vessel, a solid plug of tin and nitride precipitates supports a circulating bath of liquid tin therein. Spent nuclear fuel is immersed in the liquid tin under an atmosphere of nitrogen, resulting in the formation of nitride precipitates. The layer of liquid tin and nitride precipitates which interfaces the plug is solidified and integrated with the plug. Part of the plug is melted, removing nitride precipitates from the containment vessel, while a portion of the plug remains solidified to support te liquid tin and nitride precipitates remaining in the containment vessel. The process is practiced numerous times until substantially all of the precipitated nitrides are removed from the containment vessel.

  20. Nuclear reactor

    DOEpatents

    Wade, Elman E.

    1979-01-01

    A nuclear reactor including two rotatable plugs and a positive top core holddown structure. The top core holddown structure is divided into two parts: a small core cover, and a large core cover. The small core cover, and the upper internals associated therewith, are attached to the small rotating plug, and the large core cover, with its associated upper internals, is attached to the large rotating plug. By so splitting the core holddown structures, under-the-plug refueling is accomplished without the necessity of enlarging the reactor pressure vessel to provide a storage space for the core holddown structure during refueling. Additionally, the small and large rotating plugs, and their associated core covers, are arranged such that the separation of the two core covers to permit rotation is accomplished without the installation of complex lifting mechanisms.

  1. Post-stenotic plug-like jet with a vortex ring demonstrated by 4D flow MRI.

    PubMed

    Kim, Guk Bae; Ha, Hojin; Kweon, Jihoon; Lee, Sang Joon; Kim, Young-Hak; Yang, Dong Hyun; Kim, Namkug

    2016-05-01

    To investigate the details of the flow structure of a plug-like jet that had a vortex ring in pulsatile stenotic phantoms using 4D flow MRI. Pulsatile Newtonian flows in two stenotic phantoms with 50% and 75% reductions in area were scanned by 4D flow MRI. Blood analog working fluid was circulated via the stenotic phantom using a pulsatile pump at a constant pulsating frequency of 1Hz. The velocity and vorticity fields of the plug-like jet with a vortex ring were quantitatively analyzed in the spatial and temporal domains. Pulsatile stenotic flow showed a plug-like jet at the specific stenotic degree of 50% in our pulsatile waveform design. This plug-like jet was found at the decelerating period in the post-stenotic region of 26.4mm (1.2 D). It revealed a vortex ring structure with vorticity strength in the range of ±100s(-1). We observed a plug-like jet with a vortex ring in pulsatile stenotic flow by in vitro visualization using 4D flow MRI. In this plug-like jet, the local fastest flow region occurred at the post-systole phase in the post-stenotic region, which was distinguishable from a typical stenotic jet flow at systole phase. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Analyses of sulfonamide antibiotics by a successive anion- and cation-selective injection coupled to microemulsion electrokinetic chromatography.

    PubMed

    Lin, Yun-Ta; Liu, Yu-Wei; Cheng, Yi-Jie; Huang, Hsi-Ya

    2010-07-01

    In this study, an MEEKC was used to detect and analyze nine sulfonamide antibiotics. Owing to an insufficient sensitivity of on-column UV detection, a field-amplified sample injection, successive anion- and cation-selective injection, was used for the on-line concentration of the nine antibiotics. In the successive anion- and cation-selective injection mode, a leading water plug was introduced prior to anion injection, and then an acidic plug followed by a terminal water plug had to be used before subsequent cation injection. The results indicated some sulfonamides (sulfamonomethoxine, sulfamethazine, sulfamerazine and sulfadiazine) were determined as split signals in pairs, and this was likely due to the use of a longer acid plug (360 s) which caused the sulfonamide anions and cations to be stacked in two distinct zones of the leading water and acid plugs. Meanwhile, all the sulfonamides that were introduced either by anion or cation injection were stacked within the leading water plug when a shorter acid plug (210 s) was used. As a result, the nine sulfonamides were determined as single and symmetrical peaks with low LODs (0.9-4.2 microg/L). Furthermore, the MEEKC method was successfully applied for the detection of trace sulfonamide residues in several food and water samples.

  3. Termination of flat conductor cable to NASA/MSFC plugs

    NASA Technical Reports Server (NTRS)

    Angele, W.

    1972-01-01

    Data, supplemented with artwork, are presented on the major steps involved with terminating flat conductor cable (FCC) to MSFC's FCC plugs. Cable and shield preparation steps include material cutting, insulation stripping, and plating of exposed conductors. Methods and equipment required to terminate FCC to each of four MSFC plugs are described.

  4. 40 CFR 146.10 - Plugging and abandoning Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM: CRITERIA AND STANDARDS General... of drinking water. The Director may allow Class III wells to use other plugging materials if the... sources of drinking water. (2) Placement of the cement plugs shall be accomplished by one of the following...

  5. Plug-In Tutor Agents: Still Pluggin'

    ERIC Educational Resources Information Center

    Ritter, Steven

    2016-01-01

    "An Architecture for Plug-in Tutor Agents" (Ritter and Koedinger 1996) proposed a software architecture designed around the idea that tutors could be built as plug-ins for existing software applications. Looking back on the paper now, we can see that certain assumptions about the future of software architecture did not come to be, making…

  6. Smith and Navistar Electric and Plug-In Hybrid Vehicle Testing |

    Science.gov Websites

    plug-in hybrid electric vehicles operated by a variety of companies in diverse climates across the plug-in hybrid electric drive systems in medium-duty trucks operating in fleet service across the nation. U.S. companies agreeing to participate in this evaluation project received funding from the

  7. NREL Validates Plug-In Hybrid Truck for Pacific Gas and Electric Company |

    Science.gov Websites

    Energy Systems Integration Facility | NREL Pacific Gas and Electric Company NREL Validates Plug -In Hybrid Truck for Pacific Gas and Electric Company NREL is evaluating and analyzing a Pacific Gas and Electric Company (PG&E) plug-in hybrid electric utility truck developed by Efficient

  8. Free-jet acoustic investigation of high-radius-ratio coannular plug nozzles

    NASA Technical Reports Server (NTRS)

    Knott, P. R.; Janardan, B. A.; Majjigi, R. K.; Bhutiani, P. K.; Vogt, P. G.

    1984-01-01

    The experimental and analytical results of a scale model simulated flight acoustic exploratory investigation of high radius ratio coannular plug nozzles with inverted velocity and temperature profiles are summarized. Six coannular plug nozzle configurations and a baseline convergent conical nozzle were tested for simulated flight acoustic evaluation. The nozzles were tested over a range of test conditions that are typical of a Variable Cycle Engine for application to advanced high speed aircraft. It was found that in simulate flight, the high radius ratio coannular plug nozzles maintain their jet noise and shock noise reduction features previously observed in static testing. The presence of nozzle bypass struts will not significantly affect the acousticn noise reduction features of a General Electric type nozzle design. A unique coannular plug nozzle flight acoustic spectral prediction method was identified and found to predict the measured results quite well. Special laser velocimeter and acoustic measurements were performed which have given new insights into the jet and shock noise reduction mechanisms of coannular plug nozzles with regard to identifying further benificial research efforts.

  9. Joule-Thomson valves for long term service in space cryocoolers

    NASA Technical Reports Server (NTRS)

    Lester, J. M.; Benedict, B.

    1985-01-01

    Joule-Thomson valves for small cryocoolers have throttling passages on the order of 0.1 millimeter in diameter. Consequently, they can become plugged easily and stop the operation of the cooler. Plugging can be caused by solid particles, liquids or gases. Plugging is usually caused by the freezing of contaminant gases from the process stream. In small open loop coolers and in closed loop coolers where periodic maintenance is allowed, the problem is overcome by using careful assembly techniques, pure process gases, warm filters and cold adsorbers. A more thorough approach is required for closed loop cryocoolers which must operate unattended for long periods. This paper presents the results of an effort to solve this problem. The causes of plugging are examined, and various ways to eliminate plugging are discussed. Finally, the development of a J-T defroster is explained. It is concluded that a combination of preventive measures and a defroster will reduce the chance of cooler failure by plugging to such a degree that J-T coolers can be used for long term space missions.

  10. Damage Tolerance Assessment of Friction Pull Plug Welds in an Aluminum Alloy

    NASA Technical Reports Server (NTRS)

    McGill, Preston; Burkholder, Jonathan

    2012-01-01

    Friction stir welding is a solid state welding process used in the fabrication of cryogenic propellant tanks. Self-reacting friction stir welding is one variation of the friction stir weld process being developed for manufacturing tanks. Friction pull plug welding is used to seal the exit hole that remains in a circumferential self-reacting friction stir weld. A friction plug weld placed in a self-reacting friction stir weld results in a non-homogenous weld joint where the initial weld, plug weld, their respective heat affected zones and the base metal all interact. The welded joint is a composite plastically deformed material system with a complex residual stress field. In order to address damage tolerance concerns associated with friction plug welds in safety critical structures, such as propellant tanks, nondestructive inspection and proof testing may be required to screen hardware for mission critical defects. The efficacy of the nondestructive evaluation or the proof test is based on an assessment of the critical flaw size. Test data relating residual strength capability to flaw size in an aluminum alloy friction plug weld will be presented.

  11. Periapical tissue healing after post space preparation with or without use of a protection plug and root canal exposure to the oral environment. Study in dogs.

    PubMed

    Holland, Roberto; Manne, Luciana Noronha; de Souza, Valdir; Murata, Sueli Satomi; Dezan Júnior, Eloi

    2007-01-01

    The purpose of this study was to evaluate the influence of coronal leakage on the healing of dogs' periapical tissues after root canal filling, post space preparation and protection or not with a temporary sealer plug. Forty root canals of dogs' teeth were instrumented and filled by the lateral condensation technique with gutta-percha points and Endomethasone or CRCS sealers. After post space preparation, the remaining filling material was protected or not with a plug of temporary Coltosol sealer and exposed to the oral environment for 90 days. Thereafter, the animals were sacrificed and the specimens were removed and prepared for histomorphological and histobacteriological analysis. The findings revealed 35% of microbial leakage in the groups without plugs and 15% of leakage in the groups with plugs. Statistical analysis showed that the use of a Coltosol plug improved significantly the histomorphological results regardless of the type of root canal sealer (p=0.05) and that CRCS and Endomethasone sealers showed similar results (p>0.05).

  12. Large discharge-volume, silent discharge spark plug

    DOEpatents

    Kang, Michael

    1995-01-01

    A large discharge-volume spark plug for providing self-limiting microdischarges. The apparatus includes a generally spark plug-shaped arrangement of a pair of electrodes, where either of the two coaxial electrodes is substantially shielded by a dielectric barrier from a direct discharge from the other electrode, the unshielded electrode and the dielectric barrier forming an annular volume in which self-terminating microdischarges occur when alternating high voltage is applied to the center electrode. The large area over which the discharges occur, and the large number of possible discharges within the period of an engine cycle, make the present silent discharge plasma spark plug suitable for use as an ignition source for engines. In the situation, where a single discharge is effective in causing ignition of the combustible gases, a conventional single-polarity, single-pulse, spark plug voltage supply may be used.

  13. Engaging Tenants in Reducing Plug Load Energy Use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schantz, Marta; Langner, Rois

    Plug and Process Loads (PPLs) account for an increasingly large percentage of commercial building energy use in the U.S. due to the rising number of energy intensive plug-in devices. In addition, buildings are becoming more and more efficient and plug load energy use has become an increasingly pertinent component to achieving aggressive energy targets and netzero energy status. For multi-tenant buildings, controlling plug loads in tenant spaces can be a significant challenge. Luckily, there are a number of PPL reduction strategies, best practices, and lessons learned from numerous commercial real estate and higher education leaders who have successfully engaged buildingmore » occupants and tenants in reducing PPL energy use. This paper provides actionable PPL reduction strategies and best practices that building owners and managers can immediately apply to their own buildings.« less

  14. Screening fungicides for use in fish culture: Evaluation of the agar plug transfer, cellophane transfer, and agar dilution methods

    USGS Publications Warehouse

    Bailey, Tom A.

    1983-01-01

    The reliability, reproducibility, and usefulness of three screening methods -- the cellophane transfer, the agar plug transfer, and the agar dilution -- to screen aquatic fungicides were evaluated. Achlya flagellata and Saprolegnia hypogyna were exposed to 1, 10, and 100 mg/L of malachite green to test each method. The cellophane transfer and agar plug transfer techniques had similar reliability and reproducibility in rating fungicidal activity, and were both superior to the agar dilution technique. The agar plug transfer and agar dilution techniques adequately projected in vivo activity of malachite green, but the cellophane transfer technique overestimated its activity. Overall, the agar plug transfer technique most accurately rated the activity of malachite green and was the easiest test to perform. It therefore appears to be the method of choice for testing aquatic fungicides.

  15. Surface sampling concentration and reaction probe

    DOEpatents

    Van Berkel, Gary J; Elnaggar, Mariam S

    2013-07-16

    A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

  16. Surface sampling concentration and reaction probe with controller to adjust sampling position

    DOEpatents

    Van Berkel, Gary J.; ElNaggar, Mariam S.

    2016-07-19

    A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

  17. Integrated fountain effect pump device for fluid management at low gravity

    NASA Technical Reports Server (NTRS)

    Yuan, S. W. K.; Frank, D. J.

    1988-01-01

    A new device for fluid management at low gravity is described. The system is basically the same as the enclosed capillary device using screens, in which the screens along the gallery channels are replaced by porous plugs which are responsible for both the fluid retention and pumping of He II; in this device, no downstream pump is needed. The plugs in contact with liquid He on both sides act as a fountain-effect pumps (FEPs), while plugs exposed to vapor on one side behave as vapor-liquid phase separators (VLPSs). The total net rate of He II transfer into the receiving tank equals the mass flow rate through the FEP plugs minus the liquid loss from the VLPS plugs. The results of the performance analysis of this integrated FEP device are presented together with its schematic diagram.

  18. Porous plug for Gravity Probe B

    NASA Astrophysics Data System (ADS)

    Wang, Suwen; Everitt, C. W. Francis; Frank, David J.; Lipa, John A.; Muhlfelder, Barry F.

    2015-11-01

    The confinement of superfluid helium for a Dewar in space poses a unique challenge due to its propensity to minimize thermal gradients by essentially viscous-free counterflow. This poses the risk of losing liquid through a vent pipe, reducing the efficiency of the cooling process. To confine the liquid helium in the Gravity Probe B (GP-B) flight Dewar, a porous plug technique was invented at Stanford University. Here, we review the history of the porous plug and its development, and describe the physics underlying its operation. We summarize a few missions that employed porous plugs, some of which preceded the launch of GP-B. The design, manufacture and flight performance of the GP-B plug are described, and its use resulted in the successful operation of the 2441 l flight Dewar on-orbit for 17.3 months.

  19. Ford Plug-In Project: Bringing PHEVs to Market Demonstration and Validation Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Annunzio, Julie; Slezak, Lee; Conley, John Jason

    2014-03-26

    This project is in support of our national goal to reduce our dependence on fossil fuels. By supporting efforts that contribute toward the successful mass production of plug-in hybrid electric vehicles, our nation’s transportation-related fuel consumption can be offset with energy from the grid. Over four and a half years ago, when this project was originally initiated, plug-in electric vehicles were not readily available in the mass marketplace. Through the creation of a 21 unit plug-in hybrid vehicle fleet, this program was designed to demonstrate the feasibility of the technology and to help build cross-industry familiarity with the technology andmore » interface of this technology with the grid. Ford Escape PHEV Demonstration Fleet 3 March 26, 2014 Since then, however, plug-in vehicles have become increasingly more commonplace in the market. Ford, itself, now offers an all-electric vehicle and two plug-in hybrid vehicles in North America and has announced a third plug-in vehicle offering for Europe. Lessons learned from this project have helped in these production vehicle launches and are mentioned throughout this report. While the technology of plugging in a vehicle to charge a high voltage battery with energy from the grid is now in production, the ability for vehicle-to-grid or bi-directional energy flow was farther away than originally expected. Several technical, regulatory and potential safety issues prevented progressing the vehicle-to-grid energy flow (V2G) demonstration and, after a review with the DOE, V2G was removed from this demonstration project. Also proving challenging were communications between a plug-in vehicle and the grid or smart meter. While this project successfully demonstrated the vehicle to smart meter interface, cross-industry and regulatory work is still needed to define the vehicle-to-grid communication interface.« less

  20. Plug-in-Gait calculation of the knee adduction moment in people with knee osteoarthritis during shod walking: comparison of two different foot marker models.

    PubMed

    Paterson, Kade L; Hinman, Rana S; Metcalf, Ben R; Bennell, Kim L; Wrigley, Tim V

    2017-01-01

    Understanding how kinematic multi-segment foot modelling influences the utility of Plug-in-Gait calculations of the knee adduction moment (KAM) during shod walking is relevant to knee osteoarthritis (OA). Multi-segment foot markers placed on the skin through windows cut in to the shoe provide a more accurate representation of foot mechanics than the traditional marker set used by Plug-in-Gait, which uses fewer markers, placed on the shoe itself. We aimed to investigate whether Plug-in-Gait calculation of the KAM differed when using a kinematic multi-segment foot model compared to the traditional Plug-in-Gait marker set. Twenty people with medial knee OA underwent gait analysis in two test conditions: i) Plug-in-Gait model with its two standard foot markers placed on the shoes and; ii) Plug-in-Gait with the heel marker virtualised from a modified-Oxford Foot Model where 8 ft markers were placed on the skin through windows cut in shoe uppers. Outcomes were the peak KAM, KAM impulse and other knee kinetic and kinematic variables. There were no differences ( P  > 0.05) in any gait variables between conditions. Excellent agreement was found for all outcome variables, with high correlations ( r  > 0.88-0.99, P  < 0.001), narrow limits of agreement and no proportional bias ( R 2  = 0.03-0.14, P  > 0.05). The mean difference and 95% confidence intervals for peak KAM were also within the minimal detectable change range demonstrating equivalence. Plug-in-Gait calculations of the KAM are not altered when using a kinematic multi-segment foot marker model with skin markers placed through windows cut in to the shoe, instead of the traditional marker set placed on top of shoes. Researchers may be confident that applying either foot model does not change the calculation of the KAM using Plug-in-Gait.

  1. Well sealing via thermite reactions

    DOEpatents

    Lowry, William Edward; Dunn, Sandra Dalvit

    2016-11-15

    A platform is formed in a well below a target plug zone by lowering a thermite reaction charge into the well and igniting it, whereby the products of the reaction are allowed to cool and expand to form a platform or support in the well. A main thermite reaction charge is placed above the platform and ignited to form a main sealing plug for the well. In some embodiments an upper plug is formed by igniting an upper thermite reaction charge above the main thermite reaction charge. The upper plug confines the products of ignition of the main thermite reaction charge.

  2. Vas deferens occlusion by percutaneous injection of polyurethane elastomer plugs: clinical experience and reversibility.

    PubMed

    Zhao, S C

    1990-05-01

    A non-incision method of vas occlusion based on the percutaneous injection of polyurethane elastomer solution to form plugs is described. The results are based on clinical experience in 12,000 men in which only 56 cases of minor complications were recorded. Follow-up of 500 men for up to 3 years demonstrated an azoospermia rate of 98%. Plugs have been removed from 86 men and, to date, 51 have made their wives pregnant. In those from which the plugs have been removed for more than 1 year (n = 31), the pregnancy rate is 100%.

  3. Electronic-type vacuum gauges with replaceable elements

    DOEpatents

    Edwards, Jr., David

    1984-01-01

    In electronic devices for measuring pressures in vacuum systems, the metal elements which undergo thermal deterioration are made readily replaceable by making them parts of a simple plug-in unit. Thus, in ionization gauges, the filament and grid or electron collector are mounted on the novel plug-in unit. In thermocouple pressure gauges, the heater and attached thermocouple are mounted on the plug-in unit. Plug-in units have been designed to function, alternatively, as ionization gauge and as thermocouple gauge, thus providing new gauges capable of measuring broader pressure ranges than is possible with either an ionization gauge or a thermocouple gauge.

  4. LST CGM Generator and Viewer Final Report CRADA No. TSB-1558-98

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vickers, Don; Larson, Don

    The purpose of this project was to jointly develop and test a software plug-in that would convert native Pro /ENGINEER digital engineering drawings to Computer Graphics Metafile (CGM) format. If it was not feasible to convert the Pro/ENGINEER files, we planned to develop and test a similar conversion of native AutoCAD engineering drawings to CGM. CGM viewer plug-ins were developed as needed. There were four main tasks in this project: 1. Requirements for CGM Plug-in 2. Product Evaluation 3. Product Development Feasibility Study 4. Developing a "Plug-In" Application.

  5. Quantum well infrared photodetectors (QWIP) with selectively regrown N-GaAs plugs

    NASA Astrophysics Data System (ADS)

    Matsukura, Yusuke; Nishino, Hironori; Tanaka, Hitoshi; Fujii, Toshio

    2001-10-01

    We fabricated the GaAs/AlGaAs Quantum Well Infrared Photo detector (QWIP) focal plane array with selectively re-grown N- GaAs interconnection plugs and demonstrated its device operation, in order to establish the technology to obtain both complex device functions and device manufacturability. MBE (Molecular Beam Epitaxy) grown QWIP MQW wafers were covered with SiON and SiNx mask films to obtain selectivity of the re-growth process. N-GaAs plugs were re-grown selectively with low-pressure MOCVD (Metal-Organic Chemical Vapor Deposition) with AsH3 and Dimethylgalliumchloride as precursors, only on the bottom surfaces of the holes for the interconnection to extract the electrodes from the underlying epilayer. Cross- sectional SEM observation revealed that the feature of the re- grown N-GaAs plugs was triangular, rather than rectangular as expected. The reason for this discrepancy is not yet clear. The electrical contact between the epilayer and re-grown N- GaAs plug was 'ohmic-like,' without any trace of interfacial barrier. The Current-Voltage characteristics of the fabricated QWIP device showed no tangible leakage current between the N- GaAs plug and device structure, indicating that electrical insulation between the N-GaAs plugs and device structure was sufficient. Fabricated devices were successfully operated as a hybrid focal plane array, indicating the selective re-growth was a promising technique to realize complex QWIP based devices.

  6. The induction and compensation of asymmetric eye movements following unilateral blockage of a horizontal semicircular canal in the rabbit.

    PubMed

    Barmack, N H; Pettorossi, V E

    1988-08-01

    The influence of unilateral plugs of the left horizontal semicircular canal (LHC plugs) of rabbits on the development and compensation of asymmetric eye movements evoked by horizontal vestibular stimulation was studied. LHC plugs caused an immediate reduction of 50-65% in the gain of the horizontal vestibuloocular reflex (HVOR). This reduction in gain was achieved without altering the symmetry of the HVOR, and was accompanied by a change in the axial alignment of eye movements evoked by vestibular stimulation about the vertical (HVOR) and longitudinal (VVOR) axes. Postoperative asymmetry of eye movements developed 12-48 hr after the plugging operation. The development of asymmetry was reduced if the rabbit was restrained for 24 hr, thereby minimizing vestibular stimulation following the plugging operation. Over a 3-4 week period, the normal symmetry of eye movements was restored and the axial alignments of the HVOR and VVOR returned to the preoperative values. The gain of the HVOR did not recover. The horizontal cervicoocular reflex (HCOR) was examined before the plugging operation and after compensation of asymmetry was complete. The gain and phase of the HCOR were not altered. A relatively simple set of explanations at a cellular level is proposed to account for the induction and compensation of asymmetric eye movements following a unilateral plug of the horizontal semicircular canal.

  7. Liquid microjunction surface sampling probe fluid dynamics: Characterization and application of an analyte plug formation operational mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ElNaggar, Mariam S.; Van Berkel, Gary J.

    2011-08-10

    The recently discovered sample plug formation and injection operational mode of a continuous flow, coaxial tube geometry, liquid microjunction surface sampling probe (LMJ-SSP) (J. Am. Soc. Mass Spectrom, 2011) was further characterized and applied for concentration and mixing of analyte extracted from multiple areas on a surface and for nanoliter-scale chemical reactions of sampled material. A transparent LMJ-SSP was constructed and colored analytes were used so that the surface sampling process, plug formation, and the chemical reactions could be visually monitored at the sampling end of the probe before being analyzed by mass spectrometry of the injected sample plug. Injectionmore » plug peak widths were consistent for plug hold times as long as the 8 minute maximum attempted (RSD below 1.5%). Furthermore, integrated injection peak signals were not significantly different for the range of hold times investigated. The ability to extract and completely mix individual samples within a fixed volume at the sampling end of the probe was demonstrated and a linear mass spectral response to the number of equivalent analyte spots sampled was observed. Lastly, using the color and mass changing chemical reduction of the redox dye 2,6-dichlorophenol-indophenol with ascorbic acid, the ability to sample, concentrate, and efficiently run reactions within the same plug volume within the probe was demonstrated.« less

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: RESIDENTIAL ELECTRIC POWER GENERATION USING THE PLUG POWER SU1 FUEL CELL SYSTEM

    EPA Science Inventory

    The Environmental Technology Verification report discusses the technology and performance of the Plug Power SU1 Fuel Cell System manufactured by Plug Power. The SU1 is a proton exchange membrane fuel cell that requires hydrogen (H2) as fuel. H2 is generally not available, so the ...

  9. 40 CFR 600.302-12 - Fuel economy label-general provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... includes hybrid electric vehicles that do not have plug-in capability. Include a logo corresponding to the..., include a fuel pump logo and the designation “E85”. (iii) Identify plug-in hybrid electric vehicles as... fuel pump logo as specified in paragraph (b)(3)(i) of this section and an electric plug logo to the...

  10. 40 CFR 600.302-12 - Fuel economy label-general provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... includes hybrid electric vehicles that do not have plug-in capability. Include a logo corresponding to the..., include a fuel pump logo and the designation “E85”. (iii) Identify plug-in hybrid electric vehicles as... fuel pump logo as specified in paragraph (b)(3)(i) of this section and an electric plug logo to the...

  11. 46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Fusible plugs (modifies A-19 through A-21). 52.01-50 Section 52.01-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-50 Fusible plugs (modifies A-19 through A-21). (a) All...

  12. 46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Fusible plugs (modifies A-19 through A-21). 52.01-50 Section 52.01-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-50 Fusible plugs (modifies A-19 through A-21). (a) All...

  13. 46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Fusible plugs (modifies A-19 through A-21). 52.01-50 Section 52.01-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-50 Fusible plugs (modifies A-19 through A-21). (a) All...

  14. 46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Fusible plugs (modifies A-19 through A-21). 52.01-50 Section 52.01-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-50 Fusible plugs (modifies A-19 through A-21). (a) All...

  15. Mechanics Model of Plug Welding

    NASA Technical Reports Server (NTRS)

    Zuo, Q. K.; Nunes, A. C., Jr.

    2015-01-01

    An analytical model has been developed for the mechanics of friction plug welding. The model accounts for coupling of plastic deformation (material flow) and thermal response (plastic heating). The model predictions of the torque, energy, and pull force on the plug were compared to the data of a recent experiment, and the agreements between predictions and data are encouraging.

  16. Alternative Fuels Data Center: North Carolina Airport Advances With Plug-In

    Science.gov Websites

    Electric BusesA> North Carolina Airport Advances With Plug-In Electric Buses to someone by E-mail passengers with plug-in hybrid electric buses. For information about this project, contact Centralina Clean . Provided by Maryland Public Television Related Videos Photo of a car Electric Vehicles Charge up at State

  17. Alternative Fuels Data Center: Hybrid and Plug-In Electric Vehicle

    Science.gov Websites

    Emissions Data Sources and Assumptions Hybrid and Plug-In Electric Vehicle Emissions Data Sources and Assumptions to someone by E-mail Share Alternative Fuels Data Center: Hybrid and Plug-In Electric Vehicle Emissions Data Sources and Assumptions on Facebook Tweet about Alternative Fuels Data

  18. 30 CFR 250.1712 - What information must I submit before I permanently plug a well or zone?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Recent well test data and pressure data, if available; (c) Maximum possible surface pressure, and how it... permanently plug a well or zone? 250.1712 Section 250.1712 Mineral Resources MINERALS MANAGEMENT SERVICE... Decommissioning Activities Permanently Plugging Wells § 250.1712 What information must I submit before I...

  19. Dermoscopy of accessory nipples in authors’ own study

    PubMed Central

    Szymszal, Jan; Silny, Wojciech

    2014-01-01

    Introduction The accessory nipple (AN) is characterised by its network-like structures, which may suggest the diagnosis of a melanocytic lesion. The knowledge about additional dermoscopic features of AN may greatly minimise the risk of unnecessary surgical excisions. Aim To analyse and present different clinical and dermoscopic forms, in which the AN may appear. Material and methods Ninety AN with dermoscopic features were evaluated in the study, detected in 14 patients between the years 2008 and 2014. Results The most common dermoscopic features of the AN were central, scar-like areas (15/19) and peripheral network-like structures (12/19). A number of cleft-like appearances (8/19) and central network-like structures (7/19) had also been observed. Moreover, among the dermoscopic features, white cobblestone-like structures (7/19), a central round dimpling with a plug (6/19) and fisheye-like structures resembling comedo-like openings (9/19) have all also been noted. There is a statistical significance in the occurrence of white cobblestone-like structures with central network-like structures (Fisher's exact test p = 0.0449). The presence of peripheral network-like structures with the occurrence of central scar-like areas was statistically highly significant (p = 0.0091). The central round dimpling was never observed alongside any central network-like structures in any of the lesions (p = 0.0436). Conclusions Accessory nipples are most commonly characterised by the occurrence of a peripheral network-like structure accompanied by the presence of a scar-like area. PMID:25097482

  20. Fluid Mechanics of Capillary-Elastic Instabilities in Microgravity Environment

    NASA Technical Reports Server (NTRS)

    Grotberg, James B.

    2002-01-01

    The aim of this project is to investigate the closure and reopening of lung airways due to surface tension forces, coupled with airway elasticity. Airways are liquid-lined, flexible tubes and closure of airways can occur by a Rayleigh instability of the liquid lining, or an instability of the elastic support for the airway as the surface tension of the air-liquid interface pulls the tube shut, or both. Regardless of the mechanism, the airway is closed because the liquid lining has created a plug that prevents axial gas exchange. In the microgravity environment, surface tension forces dominate lung mechanics and would lead to more prevalent, and more uniformly distributed air-way closure, thereby creating a potential for respiratory problems for astronauts. Once closed the primary option for reopening an airway is by deep inspiration. This maneuver will pull the flexible airways open and force the liquid plug to flow distally by the incoming air stream. Airway reopening depends to a large extent on this plug flow and how it may lead to plug rupture to regain the continuity of gas between the environment and the alveoli. In addition to mathematical modeling of plug flows in liquid-lined, flexible tubes, this work has involved benchtop studies of propagating liquid plugs down tube networks that mimic the human airway tree. We have extended the work to involve animal models of liquid plug propagation in rat lungs. The liquid is radio-opaque and x-ray video imaging is used to ascertain the movement and distribution of the liquid plugs so that comparisons to theory may be made. This research has other uses, such as the delivery of liquids or drugs into the lung that may be used for surfactant replacement therapy or for liquid ventilation.

  1. Methodology for Mechanical Property Testing of Fuel Cladding Using a Expanded Plug Wedge Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Hao; Wang, Jy-An John

    2014-01-01

    An expanded plug method was developed earlier for determining the tensile properties of irradiated fuel cladding. This method tests fuel rod cladding ductility by utilizing an expandable plug to radially stretch a small ring of irradiated cladding material. The circumferential or hoop strain is determined from the measured diametrical expansion of the ring. A developed procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves, from which material properties of the cladding can be extracted. However, several deficiencies existed in this expanded-plug test that can impact the accuracy of test results, suchmore » as that the large axial compressive stress resulted from the expansion plug test can potentially induce the shear failure mode of the tested specimen. Moreover, highly nonuniform stress and strain distribution in the deformed clad gage section and significant compressive stresses, induced by bending deformation due to clad bulging effect, will further result in highly nonconservative estimates of the mechanical properties for both strength and ductility of the tested clad. To overcome the aforementioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. By optimizing the specific geometry designs, selecting the appropriate material for the expansion plug, and adding new components into the testing system, a modified expansion plug testing protocol has been developed. A general procedure was also developed to determine the hoop stress in the tested ring specimen. A scaling factor, -factor, was used to convert the ring load Fring into hoop stress , and is written as _ = F_ring/tl , where t is the clad thickness and l is the clad length. The generated stress-strain curve agrees well with the associated tensile test data in both elastic and plastic deformation regions.« less

  2. Acoustic and aerodynamic performance investigation of inverted velocity profile coannular plug nozzles. [variable cycle engines

    NASA Technical Reports Server (NTRS)

    Knott, P. R.; Blozy, J. T.; Staid, P. S.

    1981-01-01

    The results of model scale parametric static and wind tunnel aerodynamic performance tests on unsuppressed coannular plug nozzle configurations with inverted velocity profile are discussed. The nozzle configurations are high-radius-ratio coannular plug nozzles applicable to dual-stream exhaust systems typical of a variable cycle engine for Advanced Supersonic Transport application. In all, seven acoustic models and eight aerodynamic performance models were tested. The nozzle geometric variables included outer stream radius ratio, inner stream to outer stream ratio, and inner stream plug shape. When compared to a conical nozzle at the same specific thrust, the results of the static acoustic tests with the coannular nozzles showed noise reductions of up to 7 PNdB. Extensive data analysis showed that the overall acoustic results can be well correlated using the mixed stream velocity and the mixed stream density. Results also showed that suppression levels are geometry and flow regulation dependent with the outer stream radius ratio, inner stream-to-outer stream velocity ratio and inner stream velocity ratio and inner stream plug shape, as the primary suppression parameters. In addition, high-radius ratio coannular plug nozzles were found to yield shock associated noise level reductions relative to a conical nozzle. The wind tunnel aerodynamic tests showed that static and simulated flight thrust coefficient at typical takeoff conditions are quite good - up to 0.98 at static conditions and 0.974 at a takeoff Mach number of 0.36. At low inner stream flow conditions significant thrust loss was observed. Using an inner stream conical plug resulted in 1% to 2% higher performance levels than nozzle geometries using a bent inner plug.

  3. Unconventional nozzle tradeoff study. [space tug propulsion

    NASA Technical Reports Server (NTRS)

    Obrien, C. J.

    1979-01-01

    Plug cluster engine design, performance, weight, envelope, operational characteristics, development cost, and payload capability, were evaluated and comparisons were made with other space tug engine candidates using oxygen/hydrogen propellants. Parametric performance data were generated for existing developed or high technology thrust chambers clustered around a plug nozzle of very large diameter. The uncertainties in the performance prediction of plug cluster engines with large gaps between the modules (thrust chambers) were evaluated. The major uncertainty involves, the aerodynamics of the flow from discrete nozzles, and the lack of this flow to achieve the pressure ratio corresponding to the defined area ratio for a plug cluster. This uncertainty was reduced through a cluster design that consists of a plug contour that is formed from the cluster of high area ratio bell nozzles that have been scarfed. Light-weight, high area ratio, bell nozzles were achieved through the use of AGCarb (carbon-carbon cloth) nozzle extensions.

  4. Iron Mountain Electromagnetic Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gail Heath

    2012-07-01

    Iron Mountain Mine is located seventeen miles northwest of Redding, CA. After the completion of mining in early 1960s, the mine workings have been exposed to environmental elements which have resulted in degradation in water quality in the surrounding water sheds. In 1985, the EPA plugged ore stoops in many of the accessible mine drifts in an attempt to restrict water flow through the mine workings. During this process little data was gathered on the orientation of the stoops and construction of the plugs. During the last 25 years, plugs have begun to deteriorate and allow acidic waters from themore » upper workings to flow out of the mine. A team from Idaho National Laboratory (INL) performed geophysical surveys on a single mine drift and 3 concrete plugs. The project goal was to evaluate several geophysical methods to determine competence of the concrete plugs and orientation of the stopes.« less

  5. Investigation of Thrust and Drag Characteristics of a Plug-type Exhaust Nozzle

    NASA Technical Reports Server (NTRS)

    Hearth, Donald P; Gorton, Gerald C

    1954-01-01

    An investigation was conducted in the 8- by 6-foot supersonic wind tunnel on the external and internal characteristics of a plug-type exhaust nozzle. Two positions of the center plug, one simulating a convergent nozzle and the other a convergent-divergent nozzle, were investigated. Data were obtained at free-stream Mach numbers of 0.1, 0.6, 1.6, and 2.0 over a pressure-ratio range of 1 to 20 and angles of attack of zero and 8 degrees. Results of this investigation indicated that the plug nozzle had thrust-minus-drag performance over the entire pressure-ratio range comparable with equivalent conventional nozzles. The effect of the exhaust jet on the external aerodynamics was similar to results observed for conventional nozzles. In addition, the thrust characteristics were generally insensitive to external flow and good agreement was noted with data obtained on comparable plug nozzles in quiescent air.

  6. Temporary plugging agent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, H.N.; Melton, L.L.

    1966-01-04

    A temporary plugging agent, fracturing fluid and/or channel sealing agent is introduced into a selected area of a formation. The water-gelled fluid agent contains sodium borate, sodium tetraborate, and borax. It also contains a chemical breaker such as benzotrichloride, benzylidene chloride, or benzyl chloride. The water-gelled fluid consists essentially of water and from about 1-3% by weight of water of a finely powdered water-soluble gum of the galactomannan class. The borate compound is included in an amount of about 10% by weight of the gum to delay the reaction with the gel and to form a rubbery jelly-like mass withmore » it. The fluid composition has a delaying solidifying action and after a given interval of time it forms a plug. After a predetermined time, acid is produced upon the hydrolysis of the breaker in the plug and removes the plug from the area.« less

  7. Plug-Load Control and Behavioral Change Research in GSA Office Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Metzger, I.; Cutler, D.; Sheppy, M.

    2012-10-01

    The U.S. General Services Administration (GSA) owns and leases over 354 million square feet (ft2) of space in over 9,600 buildings [1]. GSA is a leader among federal agencies in aggressively pursuing energy efficiency (EE) opportunities for its facilities and installing renewable energy (RE) systems to provide heating, cooling, and power to these facilities. According to several energy assessments of GSA's buildings conducted by the National Renewable Energy Laboratory (NREL), plug-loads account for approximately 21% of the total electricity consumed within a standard GSA Region 3 office building. This study aims to provide insight on how to effectively manage plug-loadmore » energy consumption and attain higher energy and cost savings for plug-loads. As GSA improves the efficiency of its building stock, plug-loads will become an even greater portion of its energy footprint.« less

  8. Elimination of toxicity from polyurethane foam plugs used for plant culture

    NASA Technical Reports Server (NTRS)

    Wheeler, R. M.; Schwartzkopf, S. H.; Tibbitts, T. W.; Langhans, R. W.

    1985-01-01

    Polyurethane foam plugs commonly are used as collars or supports to grow plants in solution culture. Despite their utility, these foam plugs can be quite toxic to plants, particularly to small seedlings. We have observed tissue injury in tests using plugs to support lettuce, red beet, and potato plants in solution culture. Typically, the injury is initiated on the hypocotyl or stem tissue in direct contact with the foam, and appears within 30 hr as a brownish discoloration on the tissue surface. This discoloration can be followed by complete collapse of affected tissue and eventual death of the seedling. When injury does not progress beyond surface browning, the seedling survives but growth is slowed. In this paper, we report on different treatments that can be used to remove the toxicity of these plugs so they can be used in plant research.

  9. Waste isolation pilot plant (WIPP) borehole plugging program description

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christensen, C.L.; Hunter, T.O.

    1979-08-01

    The tests and experiments described attempt to provide a mix of borehole (with limited access) and in-mine (with relatively unlimited access) environments in which assessment of the various issues involved can be undertaken. The Bell Canyon Test provides the opportunity to instrument and analyze a plug in a high pressure region. The Shallow Hole Test permits application of best techniques for plugging and then access to both the top and bottom of the plug for further analysis. The Diagnostic Test Hole permits recovery of bench scale size samples for analysis and establishes an in-borehole laboratory in which to conduct testingmore » and analysis in all strata from the surface into the salt horizon. The additional in mine experiments provide the opportunity to investigate in more detail specific effects on plugs in the salt region and allows evaluation of instrumentation systems.« less

  10. 2195 Aluminum-Copper-Lithium Friction Plug Welding Development

    NASA Technical Reports Server (NTRS)

    Takeshita, Rike P.; Hartley, Paula J.; Baker, Kent S.

    1997-01-01

    Technology developments and applications of friction plug welding is presented. This friction repair welding technology is being studied for implementation on the Space Transportation System's Super Light Weight External Tank. Single plug repairs will be used on a vast majority of weld defects, however, linear defects of up to several inches can be repaired by overlapping plug welds. Methods and results of tensile, bend, simulated service, surface crack tension and other tests at room and cryogenic temperatures is discussed. Attempts to implement Friction Plug Welding has led to both tool and process changes in an attempt to minimize expansive tooling and lengthy implementation times. Process control equipment and data storage methods intended for large scale production will also be addressed. Benefits include increased strength and toughness, decreased weld repair time, automated and highly reliable process, and a lower probability of having to re-repair defect locations.

  11. A Case of Infantile Kyrle-Flegel Disease in a 6-Year-Old Yemeni Girl.

    PubMed

    Alshami, Mohammad Ali; Mohana, Mona Jameel

    2016-01-01

    Kyrle disease (KD) and Flegel disease (FD) are rare variants of primary perforating dermatoses, characterized by transepidermal elimination of abnormal endogenous materials. We describe a 6-year-old Yemeni girl with a 2-year history of generalized asymptomatic, small, reddish-brown keratotic papules with a lenticular central keratotic plug. Although these features are synonymous with FD, the histology of a punch biopsy was consistent with KD. The patient was otherwise healthy, and no family members had a history of similar diseases. The patient was diagnosed with KD-FD, owing to the manifestation of features associated with both diseases.

  12. A Case of Infantile Kyrle-Flegel Disease in a 6-Year-Old Yemeni Girl

    PubMed Central

    Alshami, Mohammad Ali; Mohana, Mona Jameel

    2016-01-01

    Kyrle disease (KD) and Flegel disease (FD) are rare variants of primary perforating dermatoses, characterized by transepidermal elimination of abnormal endogenous materials. We describe a 6-year-old Yemeni girl with a 2-year history of generalized asymptomatic, small, reddish-brown keratotic papules with a lenticular central keratotic plug. Although these features are synonymous with FD, the histology of a punch biopsy was consistent with KD. The patient was otherwise healthy, and no family members had a history of similar diseases. The patient was diagnosed with KD-FD, owing to the manifestation of features associated with both diseases. PMID:26933407

  13. Save our secondary: recovering a broken 1.3-m mirror

    NASA Astrophysics Data System (ADS)

    Abbott, Timothy M. C.; Probst, Ronald G.; Poczulp, Gary; Tighe, Roberto; Schurter, Patricio; Montané, Andrés.; DeVries, Joseph; Harris, Ronald C.; Elias, Jonathan; Martinez, Manuel; Saa, Oscar

    2014-07-01

    In an inauspicious start to the ultimately very successful installation of the Dark Energy Camera on the V. M. Blanco 4- m telescope at CTIO, the light-weighted Cer-Vit 1.3-m-diameter secondary mirror suffered an accident in which it fell onto its apex. This punched out a central plug of glass and destroyed the focus and tip/tilt mechanism. However, the mirror proved fully recoverable, without degraded performance. This paper describes the efforts through which the mirror was repaired and the tip/tilt mechanism rebuilt and upgraded. The telescope re-entered full service as a Ritchey- Chrétien platform in October of 2013.

  14. The Losing Battle against Plug-and-Chug

    ERIC Educational Resources Information Center

    Kortemeyer, Gerd

    2016-01-01

    I think most physics teachers would agree that two important components of a proper solution to a numerical physics problem are to first figure out a final symbolic solution and to only plug in numbers in the end. However, in spite of our best efforts, this is not what the majority of students is actually doing. Instead, they tend to plug numbers…

  15. Plug Your Users into Library Resources with OpenSearch Plug-Ins

    ERIC Educational Resources Information Center

    Baker, Nicholas C.

    2007-01-01

    To bring the library catalog and other online resources right into users' workspace quickly and easily without needing much more than a short XML file, the author, a reference and Web services librarian at Williams College, learned to build and use OpenSearch plug-ins. OpenSearch is a set of simple technologies and standards that allows the…

  16. Hybrid and Plug-in Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-05-20

    Hybrid and plug-in electric vehicles use electricity either as their primary fuel or to improve the efficiency of conventional vehicle designs. This new generation of vehicles, often called electric drive vehicles, can be divided into three categories: hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles(PHEVs), and all-electric vehicles (EVs). Together, they have great potential to reduce U.S. petroleum use.

  17. How Much Do Electric Cars Pollute? Depends on When and Where You Plug In |

    Science.gov Websites

    News | NREL How Much Do Electric Cars Pollute? Depends on When and Where You Plug In How Much Do Electric Cars Pollute? Depends on When and Where You Plug In May 19, 2016 The transportation the potential for emissions reduction depends on when and where drivers charge their vehicles. The

  18. LOX/Methane Main Engine Glow Plug Igniter Tests and Modeling

    NASA Technical Reports Server (NTRS)

    Breisacher, Kevin; Ajmani, Kumud

    2009-01-01

    Ignition data for tests with a LOX/methane igniter that utilized a glow plug as the ignition source are presented. The tests were conducted in a vacuum can with thermally conditioned (cold) hardware. Data showing the effects of glow plug geometry, type, and igniter operating conditions are discussed. Comparisons between experimental results and multidimensional, transient computer models are also made.

  19. Shock-operated valve would automatically protect fluid systems

    NASA Technical Reports Server (NTRS)

    Branum, L. W.; Wells, G. H.

    1966-01-01

    Glandless valve shuts down high-pressure fluid systems when severe shock from an explosion or earthquake occurs. The valve uses a pendulum to support the valve closure plug in the open position. When jarred, the valve body is moved relative to the pendulum and the plug support is displaced, allowing the plug to seat and be held by spring pressure.

  20. Electrically heated particulate matter filter with recessed inlet end plugs

    DOEpatents

    Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

    2012-02-21

    A particulate matter (PM) filter includes filter walls having inlet ends and outlet ends. First adjacent pairs of the filter walls define inlet channels. Second adjacent pairs of the filter walls define outlet channels. Outlet end plugs are arranged in the inlet channels adjacent to the output ends. Inlet end plugs arranged in the outlet channels spaced from the inlet ends.

  1. METHOD FOR MAKING FUEL ELEMENTS

    DOEpatents

    Kates, L.W.; Campbell, R.W.; Heartel, R.H.W.

    1960-08-01

    A method is given for making zirconium-clad uranium wire. A tube of zirconium is closed with a zirconium plug, after which a chilled uranium core is inserted in the tube to rest against the plug. Additional plugs and cores are inserted alternately as desired. The assembly is then sheathed with iron, hot worked to the desired size, and the iron sheath removed.

  2. Repairing Foam Insulation

    NASA Technical Reports Server (NTRS)

    Corbin, J.; Buras, D.

    1986-01-01

    Large holes in polyurethane foam insulation repaired reliably by simple method. Little skill needed to apply method, used for overhead repairs as well as for those in other orientations. Plug positioned in hole to be filled and held in place with mounting fixture. Fresh liquid foam injected through plug to bond it in place. As foam cures and expands, it displaces plug outward. Protrusion later removed.

  3. Simulation on friction taper plug welding of AA6063-20Gr metal matrix composite

    NASA Astrophysics Data System (ADS)

    Hynes, N. Rajesh Jesudoss; Nithin, Abeyram M.

    2016-05-01

    Friction taper plug welding a variant of friction welding is useful in welding of similar and dissimilar materials. It could be used for joining of composites to metals in sophisticated aerospace applications. In the present work numerical simulation of friction taper plug welding process is carried out using finite element based software. Graphite reinforced AA6063 is modelled using the software ANSYS 15.0 and temperature distribution is predicted. Effect of friction time on temperature distribution is numerically investigated. When the friction time is increased to 30 seconds, the tapered part of plug gets detached and fills the hole in the AA6063 plate perfectly.

  4. Piezoelectric valve

    DOEpatents

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  5. Electronic-type vacuum gauges with replaceable elements

    DOEpatents

    Edwards, D. Jr.

    1984-09-18

    In electronic devices for measuring pressures in vacuum systems, the metal elements which undergo thermal deterioration are made readily replaceable by making them parts of a simple plug-in unit. Thus, in ionization gauges, the filament and grid or electron collector are mounted on the novel plug-in unit. In thermocouple pressure gauges, the heater and attached thermocouple are mounted on the plug-in unit. Plug-in units have been designed to function, alternatively, as ionization gauge and as thermocouple gauge, thus providing new gauges capable of measuring broader pressure ranges than is possible with either an ionization gauge or a thermocouple gauge. 5 figs.

  6. Heat-Transfer Characteristics of Partially Film Cooled Plug Nozzle on a J-85 Afterburning Turbojet Engine

    NASA Technical Reports Server (NTRS)

    Nosek, S. M.; Straight, D. M.

    1976-01-01

    Plug nozzle film cooling data were obtained downstream of a slot located at 42 percent of the total plug length on a J-85 engine. Film cooling reduced the aft end wall temperature as much as 150 K, reduced total pressure loss in the upstream convection cooling passages by 50 percent, and reduced estimated compressor bleed flow requirement by 14 percent compared to an all convectively cooled nozzle. Shock waves along the plug surface strongly influenced temperature distributions on both convection and film cooled portions. The effect was most severe at nozzle pressure ratios below 10 where adverse pressure gradients were most severe.

  7. Fiber Optic Temperature Sensor Insert for High Temperature Environments

    NASA Technical Reports Server (NTRS)

    Black, Richard James (Inventor); Costa, Joannes M. (Inventor); Moslehi, Behzad (Inventor); Zarnescu, Livia (Inventor)

    2017-01-01

    A thermal protection system (TPS) test plug has optical fibers with FBGs embedded in the optical fiber arranged in a helix, an axial fiber, and a combination of the two. Optionally, one of the optical fibers is a sapphire FBG for measurement of the highest temperatures in the TPS plug. The test plug may include an ablating surface and a non-ablating surface, with an engagement surface with threads formed, the threads having a groove for placement of the optical fiber. The test plug may also include an optical connector positioned at the non-ablating surface for protection of the optical fiber during insertion and removal.

  8. Liquid Therapy Delivery Models Using Microfluidic Airways

    NASA Astrophysics Data System (ADS)

    Mulligan, Molly K.; Grotberg, James B.; Waisman, Dan; Filoche, Marcel; Sznitman, Josué

    2013-11-01

    The propagation and break-up of viscous and surfactant-laden liquid plugs in the lungs is an active area of research in view of liquid plug installation in the lungs to treat a host of different pulmonary conditions. This includes Infant Respiratory Distress Syndrome (IRDS) the primary cause of neonatal death and disability. Until present, experimental studies of liquid plugs have generally been restricted to low-viscosity Newtonian fluids along a single bifurcation. However, these fluids reflect poorly the actual liquid medication therapies used to treat pulmonary conditions. The present work attempts to uncover the propagation, rupture and break-up of liquid plugs in the airway tree using microfluidic models spanning three or more generations of the bronchiole tree. Our approach allows the dynamics of plug propagation and break-up to be studied in real-time, in a one-to-one scale in vitro model, as a function of fluid rheology, trailing film dynamics and bronchial tree geometry. Understanding these dynamics are a first and necessary step to deliver more effectively boluses of liquid medication to the lungs while minimizing the injury caused to epithelial cells lining the lungs from the rupture of such liquid plugs.

  9. Simulation of shear plugging through thin plates using the GRIM Eulerian hydrocode

    NASA Astrophysics Data System (ADS)

    Church, P.; Cornish, R.; Cullis, I.; Lynch, N.

    2000-03-01

    Ballistic experiments have been performed using aluminum spheres against 10-mm rolled homogenous armour (RHA), MARS270, MARS300, and titanium alloy plates to investigate the influence of the plugging mechanism on material properties. The experiments have measured the threshold for plug mass and velocity as well as the recovered aluminum sphere mass over a range of velocities. Some of the experiments have been simulated using the in-house second generation Eulerian hydrocode GRIM. The calculations feature advanced material algorithms derived from interrupted tensile testing techniques and a triaxial failure model derived from notched tensile tests over a range of strain rates and temperatures. The effect of mesh resolution on the results has been investigated and understood. The simulation results illustrate the importance of the constitutive model in the shear localization process and the subsequent plugging phenomena. The stress triaxiality is seen as the dominant feature in controlling the onset and subsequent propagation of the crack leading to the shear plug. The simulations have demonstrated that accurate numerics coupled with accurate constitutive and fracture algorithms can successfully reproduce the observed experimental features. However, extrapolation of the fracture data leads to the simulations overpredicting the plug damage. The reasons for this are discussed.

  10. From catastrophic acceleration to deceleration of liquid plugs in prewetted capillary tubes

    NASA Astrophysics Data System (ADS)

    Magniez, Juan; Baudoin, Michael; Zoueshtiagh, Farzam; Lemac/Lics Team

    2016-11-01

    Liquid/gas flows in capillaries are involved in a multitude of systems including flow in porous media, petroleum extraction, imbibition of paper or flows in pulmonary airways in pathological conditions. Liquid plugs, witch compose the biphasic flows, can have a dramatic impact on patients with pulmonary obstructive diseases, since they considerably alter the circulation of air in the airways and thus can lead to severe breathing difficulties. Here, the dynamics of liquid plugs in prewetted capillary tube is investigated experimentally and theoretically, with a particular emphasis on the role of the prewetting films and of the driving condition (constant flow rate, constant pressure). For both driving conditions, the plugs can either experience a continuous increase or decrease of their size. While this phenomenon is regular in the case of imposed flow rate, a constant pressure head can lead to a catastrophic acceleration of the plug and eventually its rupture or a dramatic increase of the plug size. A theoretical model is proposed to explain the transition between theses two regimes. These results give a new insight on the critical pressure required for airways obstruction and reopening. IEMN, International Laboratory LEMAC/LICS, UMR CNRS 8520, University of Lille.

  11. RCC Plug Repair Thermal Tools for Shuttle Mission Support

    NASA Technical Reports Server (NTRS)

    Rodriguez, Alvaro C.; Anderson, Brian P.

    2010-01-01

    A thermal math model for the Space Shuttle Reinforced Carbon-Carbon (RCC) Plug Repair was developed to increase the confidence in the repair entry performance and provide a real-time mission support tool. The thermal response of the plug cover plate, local RCC, and metallic attach hardware can be assessed with this model for any location on the wing leading edge. The geometry and spatial location of the thermal mesh also matches the structural mesh which allows for the direct mapping of temperature loads and computation of the thermoelastic stresses. The thermal model was correlated to a full scale plug repair radiant test. To utilize the thermal model for flight analyses, accurate predictions of protuberance heating were required. Wind tunnel testing was performed at CUBRC to characterize the heat flux in both the radial and angular directions. Due to the complexity of the implementation of the protuberance heating, an intermediate program was developed to output the heating per nodal location for all OML surfaces in SINDA format. Three Design Reference Cases (DRC) were evaluated with the correlated plug thermal math model to bound the environments which the plug repair would potentially be used.

  12. Frequency References for Gravitational Wave Missions

    NASA Technical Reports Server (NTRS)

    Preston, Alix; Thrope, J. I.; Donelan, D.; Miner, L.

    2012-01-01

    The mitigation of laser frequency noise is an important aspect of interferometry for LISA-like missions. One portion of the baseline mitigation strategy in LISA is active stabilization utilizing opto-mechanical frequency references. The LISA optical bench is an attractive place to implement such frequency references due to its environmental stability and its access to primary and redundant laser systems. We have made an initial investigation of frequency references constructed using the techniques developed for the LISA and LISA Pathfinder optical benches. Both a Mach-Zehnder interferometer and triangular Fabry-Perot cavity have been successfully bonded to a Zerodur baseplate using the hydroxide bonding method. We will describe the construction of the bench along with preliminary stability results.

  13. Lightweight, high-frequency transformers

    NASA Technical Reports Server (NTRS)

    Schwarze, G. E.

    1983-01-01

    The 25-kVA space transformer was developed under contract by Thermal Technology Laboratory, Buffalo, N. Y. The NASA Lewis transformer technology program attempted to develop the baseline technology. For the 25-kVA transformer the input voltage was chosen as 200 V, the output voltage as 1500 V, the input voltage waveform as square wave, the duty cycle as continuous, the frequency range (within certain constraints) as 10 to 40 kHz, the operating temperatures as 85 deg. and 130 C, the baseplate temperature as 50 C, the equivalent leakage inductance as less than 10 micro-h, the operating environment as space, and the life expectancy as 10 years. Such a transformer can also be used for aircraft, ship and terrestrial applications.

  14. A novel hydrogel plug of Sterculia urens for pulsatile delivery: in vitro and in vivo evaluation.

    PubMed

    Amrutkar, Jitendra R; Gattani, Surendra G

    2012-01-01

    The objective of this study was to investigate a novel hydrogel plug using isolated root mucilage of Sterculia urens to obtain a desired lag time for an oral chronotherapeutic colon-specific pulsatile drug delivery of indomethacin. Pulsatile drug delivery was developed using chemically treated hard gelatin capsule bodies filled with eudragit multiparticulates of indomethacin, and sealed with different hydrogel plugs (root mucilage of S. urens, xanthan gum, guar gum, HPMC K4M and combination of maltodextrin with guar gum). Indomethacin multiparticulates were prepared using extrusion spheronization, spray drying and solvent evaporation techniques with Eudragit® L-100 and S-100 (1:2) by varying drug-to-polymer ratio. After oral administration, the water-soluble cap of capsule dissolved in the intestinal fluid and the hydrogel plug swells. After a controlled time, the swollen plug subsequently ejected from the dosage form, releases the contents of the capsule. The formulation factors affecting the drug release were concentration and types of hydrogel plug used. In vivo gamma scintigraphy study in healthy rabbits proved the capability of the system to release drug in lower parts of the gastrointestinal tract after a programmed lag time. This study demonstrates that the indomethacin multiparticulates could be successfully colon-targeted by the design of time and pH-dependent modified chronopharmaceutical formulation. In conclusion, the investigated novel hydrogel plug could be a valuable tool for achieving desired lag time.

  15. Does aphid salivation affect phloem sieve element occlusion in vivo?

    PubMed

    Medina-Ortega, Karla J; Walker, G P

    2013-12-01

    To protect against loss of photo-assimilate-rich phloem sap, plants have evolved several mechanisms to plug phloem sieve tubes in response to damage. In many Fabaceae, each sieve element contains a discrete proteinaceous body called a forisome, which, in response to damage, rapidly transforms from a condensed configuration that does not impede the flow of sap to a dispersed configuration that plugs the sieve element. Aphids and other specialized phloem sap feeders can ingest phloem sap from a single sieve element for hours or days, and to do this, they must be able to suppress or reverse phloem plugging. A recent study provided in vitro evidence that aphid saliva can reverse forisome plugs. The present study tested this hypothesis in vivo by inducing forisome plugs which triggered aphids to switch behaviour from phloem sap ingestion to salivation into the sieve element. After salivating into the sieve element for various periods of time, the aphids were instantaneously cryofixed (freeze fixed) in situ on their leaf. The state of the forisome was then determined in the penetrated sieve element and in nearby non-penetrated sieve elements which served as controls for sieve elements not subjected to direct aphid salivation. Forisomes were almost always in close contact with the stylet tips and thus came into direct contact with the saliva. Nonetheless, forisome plugs in the penetrated sieve element did not revert back to a non-plugging state any faster than those in neighbouring sieve elements that were not subjected to direct aphid salivation.

  16. Landscape assessment of side channel plugs and associated cumulative side channel attrition across a large river floodplain.

    PubMed

    Reinhold, Ann Marie; Poole, Geoffrey C; Bramblett, Robert G; Zale, Alexander V; Roberts, David W

    2018-04-24

    Determining the influences of anthropogenic perturbations on side channel dynamics in large rivers is important from both assessment and monitoring perspectives because side channels provide critical habitat to numerous aquatic species. Side channel extents are decreasing in large rivers worldwide. Although riprap and other linear structures have been shown to reduce side channel extents in large rivers, we hypothesized that small "anthropogenic plugs" (flow obstructions such as dikes or berms) across side channels modify whole-river geomorphology via accelerating side channel senescence. To test this hypothesis, we conducted a geospatial assessment, comparing digitized side channel areas from aerial photographs taken during the 1950s and 2001 along 512 km of the Yellowstone River floodplain. We identified longitudinal patterns of side channel recruitment (created/enlarged side channels) and side channel attrition (destroyed/senesced side channels) across n = 17 river sections within which channels were actively migrating. We related areal measures of recruitment and attrition to the density of anthropogenic side channel plugs across river sections. Consistent with our hypothesis, a positive spatial relationship existed between the density of anthropogenic plugs and side channel attrition, but no relationship existed between plug density and side channel recruitment. Our work highlights important linkages among side channel plugs and the persistence and restoration of side channels across floodplain landscapes. Specifically, management of small plugs represents a low-cost, high-benefit restoration opportunity to facilitate scouring flows in side channels to enable the persistence of these habitats over time.

  17. Does aphid salivation affect phloem sieve element occlusion in vivo?

    PubMed Central

    Medina-Ortega, Karla J.

    2013-01-01

    To protect against loss of photo-assimilate-rich phloem sap, plants have evolved several mechanisms to plug phloem sieve tubes in response to damage. In many Fabaceae, each sieve element contains a discrete proteinaceous body called a forisome, which, in response to damage, rapidly transforms from a condensed configuration that does not impede the flow of sap to a dispersed configuration that plugs the sieve element. Aphids and other specialized phloem sap feeders can ingest phloem sap from a single sieve element for hours or days, and to do this, they must be able to suppress or reverse phloem plugging. A recent study provided in vitro evidence that aphid saliva can reverse forisome plugs. The present study tested this hypothesis in vivo by inducing forisome plugs which triggered aphids to switch behaviour from phloem sap ingestion to salivation into the sieve element. After salivating into the sieve element for various periods of time, the aphids were instantaneously cryofixed (freeze fixed) in situ on their leaf. The state of the forisome was then determined in the penetrated sieve element and in nearby non-penetrated sieve elements which served as controls for sieve elements not subjected to direct aphid salivation. Forisomes were almost always in close contact with the stylet tips and thus came into direct contact with the saliva. Nonetheless, forisome plugs in the penetrated sieve element did not revert back to a non-plugging state any faster than those in neighbouring sieve elements that were not subjected to direct aphid salivation. PMID:24127515

  18. The embryologic development of the human external auditory meatus. Preliminary report.

    PubMed

    Nishimura, Y; Kumoi, T

    1992-01-01

    During the final period of embryogenesis, a funnel-shaped tube continues medially into the mesenchymal tissue forming a curved path. Although this may sound simple, the development occurring during early fetal life is in fact very complex. At first, ectodermal cells proliferate to fill the lumen of the meatus, forming the meatal plug, and then at 10 weeks the bottom of the plug extends in a disc-like fashion, so that in the horizontal plane the meatus is boot-shaped with a narrow neck and the sole of the meatal plug spreading widely to form the future tympanic membrane medially. At the same time, the plug in the proximal portion of the neck starts to be resorbed. In the 13-week fetus, the disc-like plug begins to show signs of its final destiny; the innermost surface of the plug in contact with the anlage of the malleus is ready to contribute to the formation of the tympanic membrane. In the 15-week fetus, the innermost portion of the disc-like plug splits, leaving a thin ectodermal cell layer of immature tympanic membrane. The neck of the boot forms the border between the primary and secondary meatus, and is the last part to split. In the 16.5-week fetus, the meatus is fully patent throughout its entire length, although the lumen is still narrow and curved. In the 18-week fetus, the meatus is already fully expanded to its complete form.

  19. The effect of electrode temperature on the sparking voltage of short spark gaps

    NASA Technical Reports Server (NTRS)

    Silsbee, F B

    1924-01-01

    This report presents the results of an investigation to determine what effect the temperature of spark plug electrodes might have on the voltage at which a spark occurred. A spark gap was set up so that one electrode could be heated to temperatures up to 700 degrees C., while the other electrode and the air in the gap were maintained at room temperature. The sparking voltages were measured both with direct voltage and with voltage impulse from ignition coil. It was found that the sparking voltage of the gap decreased materially with increase of temperature. This change was more marked when the hot electrode was of negative polarity. The phenomena observed can be explained by the ionic theory of gaseous conduction, and serve to account for certain hitherto unexplained actions in the operation of internal combustion engines. These results indicate that the ignition spark will pass more readily when the spark-plug design is such as to make the electrodes run hot. This possible gain is, however, very closely limited by the danger of producing preignition. These experiments also show that sparking is somewhat easier when the hot electrode (which is almost always the central electrode) is negative than when the polarity is reversed.

  20. Effects of plug-in hybrid electric vehicles on ozone concentrations in Colorado.

    PubMed

    Brinkman, Gregory L; Denholm, Paul; Hannigan, Michael P; Milford, Jana B

    2010-08-15

    This study explores how ozone concentrations in the Denver, CO area might have been different if plug-in hybrid electric vehicles (PHEVs) had replaced light duty gasoline vehicles in summer 2006. A unit commitment and dispatch model was used to estimate the charging patterns of PHEVs and dispatch power plants to meet electricity demand. Emission changes were estimated based on gasoline displacement and the emission characteristics of the power plants providing additional electricity. The Comprehensive Air Quality Model with extensions (CAMx) was used to simulate the effects of these emissions changes on ozone concentrations. Natural gas units provided most of the electricity used for charging PHEVs in the scenarios considered. With 100% PHEV penetration, nitrogen oxide (NO(x)) emissions were reduced by 27 tons per day (tpd) from a fleet of 1.7 million vehicles and were increased by 3 tpd from power plants; VOC emissions were reduced by 57 tpd. These emission changes reduced modeled peak 8-h average ozone concentrations by approximately 2-3 ppb on most days. Ozone concentration increases were modeled for small areas near central Denver. Future research is needed to forecast when significant PHEV penetration may occur and to anticipate characteristics of the corresponding power plant and vehicle fleets.

  1. HydroDesktop: An Open Source GIS-Based Platform for Hydrologic Data Discovery, Visualization, and Analysis

    NASA Astrophysics Data System (ADS)

    Ames, D. P.; Kadlec, J.; Cao, Y.; Grover, D.; Horsburgh, J. S.; Whiteaker, T.; Goodall, J. L.; Valentine, D. W.

    2010-12-01

    A growing number of hydrologic information servers are being deployed by government agencies, university networks, and individual researchers using the Consortium of Universities for the Advancement of Hydrologic Science, Inc. (CUAHSI) Hydrologic Information System (HIS). The CUAHSI HIS Project has developed a standard software stack, called HydroServer, for publishing hydrologic observations data. It includes the Observations Data Model (ODM) database and Water Data Service web services, which together enable publication of data on the Internet in a standard format called Water Markup Language (WaterML). Metadata describing available datasets hosted on these servers is compiled within a central metadata catalog called HIS Central at the San Diego Supercomputer Center and is searchable through a set of predefined web services based queries. Together, these servers and central catalog service comprise a federated HIS of a scale and comprehensiveness never previously available. This presentation will briefly review/introduce the CUAHSI HIS system with special focus on a new HIS software tool called "HydroDesktop" and the open source software development web portal, www.HydroDesktop.org, which supports community development and maintenance of the software. HydroDesktop is a client-side, desktop software application that acts as a search and discovery tool for exploring the distributed network of HydroServers, downloading specific data series, visualizing and summarizing data series and exporting these to formats needed for analysis by external software. HydroDesktop is based on the open source DotSpatial GIS developer toolkit which provides it with map-based data interaction and visualization, and a plug-in interface that can be used by third party developers and researchers to easily extend the software using Microsoft .NET programming languages. HydroDesktop plug-ins that are presently available or currently under development within the project and by third party collaborators include functions for data search and discovery, extensive graphing, data editing and export, HydroServer exploration, integration with the OpenMI workflow and modeling system, and an interface for data analysis through the R statistical package.

  2. Steel refining possibilities in LF

    NASA Astrophysics Data System (ADS)

    Dumitru, M. G.; Ioana, A.; Constantin, N.; Ciobanu, F.; Pollifroni, M.

    2018-01-01

    This article presents the main possibilities for steel refining in Ladle Furnace (LF). These, are presented: steelmaking stages, steel refining through argon bottom stirring, online control of the bottom stirring, bottom stirring diagram during LF treatment of a heat, porous plug influence over the argon stirring, bottom stirring porous plug, analysis of porous plugs disposal on ladle bottom surface, bottom stirring simulation with ANSYS, bottom stirring simulation with Autodesk CFD.

  3. Rehabilitating gravel areas with short-hair sedge sod plugs and fertilizer

    Treesearch

    Raymond D. Ratliff

    1985-01-01

    Tests to rehabilitate gravel areas in high value recreation sites were carried out by transplanting short-hair sedge (Carex exserta) plugs. The plugs were 1.9 cm (0.75 inch) and 5.1 cm (2.0 inches) in diameter, 10 cm (4.0 inches) deep, and were transplanted in September 1981, with and without papier-mache pots. The test site was Siberian Outpost, in...

  4. Percutaneous treatment of a duodenocutaneous high-flow fistula using a new biological plug

    PubMed Central

    Vallejo, Eduardo Crespo; Martinez-Galdamez, Mario; Del Olmo Martínez, Lourdes; Brunet, Eduardo Crespo; Martin, Ernesto Santos

    2015-01-01

    Enterocutaneous fistula is a challenging entity and a gold-standard treatment is not settled so far. Here, we describe the successful closure of a duodenocutaneous fistula with the use of the Biodesign enterocutaneous fistula plug (Cook Medical), which is derived from a biological plug that has been used in recent years in order to close anorectal fistula tracts. PMID:25835076

  5. NREL Research Determines Integration of Plug-in Electric Vehicles Should

    Science.gov Websites

    transportation and energy systems engineer at NREL and author of the new Nature Energy paper, "Impact of Muratori, author of the new Nature Energy paper "Impact of Uncoordinated Plug-in Electric Vehicle Integration of Plug-in Electric Vehicles Should Play a Big Role in Future Electric System Planning News

  6. Medical Device Plug-and-Play Interoperability Standards and Technology Leadership

    DTIC Science & Technology

    2017-10-01

    Award Number: W81XWH-09-1-0705 TITLE: “Medical Device Plug-and-Play Interoperability Standards and Technology Leadership” PRINCIPAL INVESTIGATOR...Sept 2016 – 20 Sept 2017 4. TITLE AND SUBTITLE “Medical Device Plug-and-Play Interoperability 5a. CONTRACT NUMBER Standards and Technology ...efficiency through interoperable medical technologies . We played a leadership role on interoperability safety standards (AAMI, AAMI/UL Joint

  7. NaK Plugging Meter Design for the Feasibility Test Loops

    NASA Technical Reports Server (NTRS)

    Pearson, J. Boise; Godfroy, Thomas J.; Reid, Robert S.; Polzin, Kurt A.

    2008-01-01

    The design and predicted performance of a plugging meter for use in the measurement of NaK impurity levels are presented. The plugging meter is incorporated into a Feasibility Test Loop (FTL), which is a small pumped-NaK loop designed to enable the rapid, small-scale evaluation of techniques such as in situ purification methods and to permit the measurement of bulk material transport effects (not mechanisms) under flow conditions that are representative of a fission surface power reactor. The FTL operates at temperatures similar to those found in a reactor, with a maximum hot side temperature of 900 K and a corresponding cold side temperature of 860 K. In the plugging meter a low flow rate bypass loop is cooled until various impurities (primarily oxides) precipitate out of solution. The temperatures at which these impurities precipitate are indicative of the level of impurities in the NaK. The precipitates incrementally plug a small orifice in the bypass loop, which is detected by monitoring changes in the liquid metal flow rate.

  8. Valley plugs, land use, and phytogeomorphic response: Chapter 14

    USGS Publications Warehouse

    Pierce, Aaron R.; King, Sammy L.; Shroder, John F.

    2013-01-01

    Anthropogenic alteration of fluvial systems can disrupt functional processes that provide valuable ecosystem services. Channelization alters fluvial parameters and the connectivity of river channels to their floodplains which is critical for productivity, nutrient cycling, flood control, and biodiversity. The effects of channelization can be exacerbated by local geology and land-use activities, resulting in dramatic geomorphic readjustments including the formation of valley plugs. Considerable variation in the response of abiotic processes, including surface hydrology, subsurface hydrology, and sedimentation dynamics, to channelization and the formation of valley plugs. Altered abiotic processes associated with these geomorphic features and readjustments influence biotic processes including species composition, abundance, and successional processes. Considerable interest exists for restoring altered fluvial systems and their floodplains because of their social and ecological importance. Understanding abiotic and biotic responses of channelization and valley-plug formation within the context of the watershed is essential to successful restoration. This chapter focuses on the primary causes of valley-plug formation, resulting fluvial-geomorphic responses, vegetation responses, and restoration and research needs for these systems.

  9. Pericardium Plug in the Repair of the Corneoscleral Fistula After Ahmed Glaucoma Valve Explantation

    PubMed Central

    Yoo, Chungkwon; Kwon, Sung Wook

    2008-01-01

    We report four cases in which a pericardium (Tutoplast®) plug was used to repair a corneoscleral fistula after Ahmed Glaucoma Valve (AGV) explantation. In four cases in which the AGV tube had been exposed, AGV explantation was performed using a pericardium (Tutoplast®) plug to seal the defect previously occupied by the tube. After debridement of the fistula, a piece of processed pericardium (Tutoplast®), measured 1 mm in width, was plugged into the fistula and secured with two interrupted 10-0 nylon sutures. To control intraocular pressure, a new AGV was implanted elsewhere in case 1, phaco-trabeculectomy was performed concurrently in case 2, cyclophotocoagulation was performed postoperatively in case 3 and anti-glaucomatous medication was added in case 4. No complication related to the fistula developed at the latest follow-up (range: 12~26 months). The pericardium (Tutoplast®) plug seems to be an effective method in the repair of corneoscleral fistulas resulting from explantation of glaucoma drainage implants. PMID:19096247

  10. Biodegradable microfabricated plug-filters for glaucoma drainage devices.

    PubMed

    Maleki, Teimour; Chitnis, Girish; Park, Jun Hyeong; Cantor, Louis B; Ziaie, Babak

    2012-06-01

    We report on the development of a batch fabricated biodegradable truncated-cone-shaped plug filter to overcome the postoperative hypotony in nonvalved glaucoma drainage devices. Plug filters are composed of biodegradable polymers that disappear once wound healing and bleb formation has progressed past the stage where hypotony from overfiltration may cause complications in the human eye. The biodegradable nature of device eliminates the risks associated with permanent valves that may become blocked or influence the aqueous fluid flow rate in the long term. The plug-filter geometry simplifies its integration with commercial shunts. Aqueous humor outflow regulation is achieved by controlling the diameter of a laser-drilled through-hole. The batch compatible fabrication involves a modified SU-8 molding to achieve truncated-cone-shaped pillars, polydimethylsiloxane micromolding, and hot embossing of biodegradable polymers. The developed plug filter is 500 μm long with base and apex plane diameters of 500 and 300 μm, respectively, and incorporates a laser-drilled through-hole with 44-μm effective diameter in the center.

  11. Implementation of a non-lethal biopsy punch monitoring program for mercury in smallmouth bass, Micropterus dolomieu Lacepède, from the Eleven Point River, Missouri

    USGS Publications Warehouse

    Ackerson, J.R.; Schmitt, C.J.; McKee, M.J.; Brumbaugh, W.G.

    2013-01-01

    A non-lethal biopsy method for monitoring mercury (Hg) concentrations in smallmouth bass (Micropterus dolomieu; smallmouth) from the Eleven Point River in southern Missouri USA was evaluated. A biopsy punch was used to remove a muscle tissue plug from the area immediately below the anterior dorsal fin of 31 smallmouth. An additional 35 smallmouth (controls) were held identically except that no tissue plug was removed. After sampling, all fish were held in a concrete hatchery raceway for 6 weeks. Mean survival at the end of the holding period was 97 % for both groups. Smallmouth length, weight and Fulton’s condition factor at the end of the holding period were also similar between plugged and non-plugged controls, indicating that the biopsy procedure had minimal impact on growth under these conditions. Tissue plug Hg concentrations were similar to smallmouth Hg data obtained in previous years by removing the entire fillet for analysis.

  12. Implementation of a non-lethal biopsy punch monitoring program for mercury in smallmouth bass, Micropterus dolomieu Lacepede, from the Eleven Point River, Missouri

    USGS Publications Warehouse

    Ackerson, R.J.; McKee, J.M.; Schmitt, C.J.; Brumbaugh, William G.

    2014-01-01

    A non-lethal biopsy method for monitoring mercury (Hg) concentrations in smallmouth bass (Micropterus dolomieu; smallmouth) from the Eleven Point River in southern Missouri USA was evaluated. A biopsy punch was used to remove a muscle tissue plug from the area immediately below the anterior dorsal fin of 31 smallmouth. An additional 35 smallmouth (controls) were held identically except that no tissue plug was removed. After sampling, all fish were held in a concrete hatchery raceway for 6 weeks. Mean survival at the end of the holding period was 97 % for both groups. Smallmouth length, weight and Fulton’s condition factor at the end of the holding period were also similar between plugged and non-plugged controls, indicating that the biopsy procedure had minimal impact on growth under these conditions. Tissue plug Hg concentrations were similar to smallmouth Hg data obtained in previous years by removing the entire fillet for analysis.

  13. GIS Application System Design Applied to Information Monitoring

    NASA Astrophysics Data System (ADS)

    Qun, Zhou; Yujin, Yuan; Yuena, Kang

    Natural environment information management system involves on-line instrument monitoring, data communications, database establishment, information management software development and so on. Its core lies in collecting effective and reliable environmental information, increasing utilization rate and sharing degree of environment information by advanced information technology, and maximizingly providing timely and scientific foundation for environmental monitoring and management. This thesis adopts C# plug-in application development and uses a set of complete embedded GIS component libraries and tools libraries provided by GIS Engine to finish the core of plug-in GIS application framework, namely, the design and implementation of framework host program and each functional plug-in, as well as the design and implementation of plug-in GIS application framework platform. This thesis adopts the advantages of development technique of dynamic plug-in loading configuration, quickly establishes GIS application by visualized component collaborative modeling and realizes GIS application integration. The developed platform is applicable to any application integration related to GIS application (ESRI platform) and can be as basis development platform of GIS application development.

  14. Plug identification in drainage system using electromagnetic wave

    NASA Astrophysics Data System (ADS)

    Hijriani, Arifa; Utama, Aji Surya; Boas, Andrianus; Mukti, M. Ridho; Widodo

    2017-07-01

    The evaluation of drainage system's performance is an important thing to do to prevent flooding. Conventionally the Government evaluates the drainage system by opening one by one the lid of drainage and detects the plug manually. This method is not effective and efficient because this method need many people, much time and relatively expensive. The purpose of this paper is to identify plugs in drainage system in G St. at Bandung Institute of Technology by using electromagnetic wave. Ground Penetrating Radar (GPR) is one of geophysics method that using electromagnetic wave with high frequency. GPR is a non-destructive method with high resolution imaging for shallow depth (˜100m) and relatively cheap. We could identify the plug without opening the lid manually so that we could save much time. GPR's sensitivity is depends on resistivity, magnetic permeability, and permittivity of an object. The result of this research is we could identify the plug on the radargram that observed by a build-up amplitude anomaly.

  15. Analysis of supersonic plug nozzle flowfield and heat transfer

    NASA Technical Reports Server (NTRS)

    Murthy, S. N. B.; Sheu, W. H.

    1988-01-01

    A number of problems pertaining to the flowfield in a plug nozzle, designed as a supersonic thruster nozzle, with provision for cooling the plug with a coolant stream admitted parallel to the plug wall surface, were studied. First, an analysis was performed of the inviscid, nonturbulent, gas dynamic interaction between the primary hot stream and the secondary coolant stream. A numerical prediction code for establishing the resulting flowfield with a dividing surface between the two streams, for various combinations of stagnation and static properties of the two streams, was utilized for illustrating the nature of interactions. Secondly, skin friction coefficient, heat transfer coefficient and heat flux to the plug wall were analyzed under smooth flow conditions (without shocks or separation) for various coolant flow conditions. A numerical code was suitably modified and utilized for the determination of heat transfer parameters in a number of cases for which data are available. Thirdly, an analysis was initiated for modeling turbulence processes in transonic shock-boundary layer interaction without the appearance of flow separation.

  16. Quick actuating closure

    NASA Technical Reports Server (NTRS)

    White, III, Dorsey E. (Inventor); Updike, deceased, Benjamin T. (Inventor); Allred, Johnny W. (Inventor)

    1989-01-01

    A quick actuating closure for a pressure vessel 80 in which a wedge ring 30 with a conical outer surface 31 is moved forward to force shear blocks 40, with conical inner surfaces 41, radially outward to lock an end closure plug 70 within an opening 81 in the pressure vessel 80. A seal ring 60 and a preload ramp 50 sit between the shear blocks 40 and the end closure plug 70 to provide a backup sealing capability. Conical surfaces 44 and 55 of the preload ramp 50 and the shear blocks 40 interact to force the seal ring 60 into shoulders 73 and 85 in the end closure plug 70 and opening 81 to form a tight seal. The end closure plug 70 is unlocked by moving the wedge ring 30 rearward, which causes T-bars 32 of the wedge ring 30 riding within T -slots 42 of the shear blocks 40 to force them radially inward. The end closure plug 70 is then removed, allowing access to the interior of the pressure vessel 80.

  17. Transient motion of mucus plugs in respiratory airways

    NASA Astrophysics Data System (ADS)

    Zamankhan, Parsa; Hu, Yingying; Helenbrook, Brian; Takayama, Shuichi; Grotberg, James B.

    2011-11-01

    Airway closure occurs in lung diseases such as asthma, cystic fibrosis, or emphysema which have an excess of mucus that forms plugs. The reopening process involves displacement of mucus plugs in the airways by the airflow of respiration. Mucus is a non-Newtonian fluid with a yield stress; therefore its behavior can be approximated by a Bingham fluid constitutive equation. In this work the reopening process is approximated by simulation of a transient Bingham fluid plug in a 2D channel. The governing equations are solved by an Arbitrary Lagrangian Eulerian (ALE) finite element method through an in-house code. The constitutive equation for the Bingham fluid is implemented through a regularization method. The effects of the yield stress on the flow features and wall stresses are discussed with applications to potential injuries to the airway epithelial cells which form the wall. The minimum driving pressure for the initiation of the motion is computed and its value is related to the mucus properties and the plug shape. Supported by HL84370 and HL85156.

  18. Best Practices for Fuel System Contamination Detection and Remediation

    DTIC Science & Technology

    2015-12-14

    Valve Fyre Ring GR DBB Style Plug Valve Gasket SS graphite Spiral DBB Style Plug Valve O- rings & slip seals VI DBB Style Plug Valve Packing gland...Pumps Impeller Key SS Vertical Turbine Pumps Impeller Retaining Ring SS Vertical Turbine Pumps Impellers (Electroless Nickel Plating) DI Vertical... Turbine Pumps Line Shaft SS Vertical Turbine Pumps Lineshaft Bearing CA Vertical Turbine Pumps Mating Ring Si-C Vertical Turbine Pumps Mechanical

  19. Best Practices for Fuel System Contamination Detection and Remediation

    DTIC Science & Technology

    2016-01-15

    Valve Fyre Ring GR DBB Style Plug Valve Gasket SS graphite Spiral DBB Style Plug Valve O- rings & slip seals VI DBB Style Plug Valve Packing gland...Pumps Impeller Key SS Vertical Turbine Pumps Impeller Retaining Ring SS Vertical Turbine Pumps Impellers (Electroless Nickel Plating) DI Vertical... Turbine Pumps Line Shaft SS Vertical Turbine Pumps Lineshaft Bearing CA Vertical Turbine Pumps Mating Ring Si-C Vertical Turbine Pumps Mechanical

  20. APPARATUS FOR LOADING AND UNLOADING A MACHINE

    DOEpatents

    Payne, J.H. Jr.

    1962-07-17

    An arrangement for loading and unloading a nuclear reactor is described. Depleted fuel elements are removed from the reactor through one of a small number of holes in a shielding plug that is rotatably mounted in an eccentric annular plug rotatably mounted in the top of the reactor. The fuel elements removed are stored in a plurality of openings in a rotatable magazine or storage means rotatably mounted over the plugs. (AEC)

  1. SU-F-T-668: Irradiating Mouse Brain with a Clinical Linear Accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perez-Torres, C

    Purpose: To design and construct a “mouse jig” device that would allow for irradiation of the mouse brain with a clinical Varian 6 MeV Linear Accelerator. This device must serve as a head immobilizer, gaseous anesthesia delivery, and radiation bolus concurrently. Methods: The mouse jig was machined out of nylon given that it is inexpensive, easy to machine, and has similar electron density to water. A cylindrical opening with diameter of 16 mm and 40 mm depth was drilled into a nylon block sized 56×56×50 mm (width, length, depth). Additional slots were included in the block for ear bars andmore » a tooth bar to serve as a three-point immobilization device as well as for anesthesia delivery and scavenging. For ease of access when loading the mouse into the holder, there is a removable piece at the top of the block that is 15 mm in depth. This serves a dual purpose, as with the proper extra shielding, the mouse jig could be used with lower linear energy transfer photons with this piece removed. A baseplate was then constructed with five square slots where the mouse jig can securely be inserted plus additional slots that would allow the baseplate to be mounted on a standard lock bar in the treatment couch. This maximizes the reproducibility of placement between imaging and treatment and between treatment sessions. Results: CT imaging and radiation treatment planning was performed that showed acceptable coverage and uniformity of radiation dose in the mouse brain while sparing the throat and eyes. Conclusion: We have designed and manufactured a device that fulfills our criteria allowing us to selectively irradiate the mouse brain with a clinical linear accelerator. This setup will be used for generating mouse models of radiation-induced brain injury.« less

  2. Solvent-free biodegradable scleral plugs providing sustained release of vancomycin, amikacin, and dexamethasone--an in vivo study.

    PubMed

    Peng, Yi-Jie; Kau, Yi-Chuan; Wen, Chin-Wei; Liu, Kuo-Sheng; Liu, Shih-Jung

    2010-08-01

    Delivering effective drugs at sufficiently high concentrations to the area of infection is a standard treatment for infectious disease, such as endophthalmitis. This is currently done by empirical trans pars plana intravitreal injection of both antibiotics directed against gram-positive and gram-negative microorganisms and steroids. However, injections by needles repeatedly may increase the risks of intraocular infection and hemorrhage, as well as retinal detachment. This article explores the alternative of using biodegradable polymers as scleral plugs for a long-term drug release in vivo. To manufacture plugs, poly(lactide-glycolide) copolymers were first mixed with vancomycin, amikacin, and dexamethasone. The mixture was compressed and sintered at 55 degrees C to form scleral plugs 1.4 mm in diameter. Biodegradable scleral plugs released high concentrations of antibiotics (well above the minimum inhibitory concentrations, MIC) and steroids in vivo for the period of time needed to treat intraocular infection. In addition, no major complications such as infectious or sterile endophthalmitis, retinal detachment, ocular phthisis, or uvea protrusion at sclerotomy site were observed throughout the experiment. The sclerotomy wound healed after total degradation of the scleral implants without leakage or local necrosis. Antibiotic/steroid-impregnated biodegradable scleral plugs may have a potential role in the treatment of various intraocular infections. (c) 2010 Wiley Periodicals, Inc.

  3. In Vitro Microfluidic Models of Mucus-Like Obstructions in Small Airways

    NASA Astrophysics Data System (ADS)

    Mulligan, Molly K.; Grotberg, James B.; Sznitman, Josué

    2012-11-01

    Liquid plugs can form in the lungs as a result of a host of different diseases, including cystic fibrosis and chronic obstructive pulmonary disease. The existence of such fluid obstructions have been found as far down in the bronchiole tree as the sixteenth generation, where bronchiole openings have diameters on the order of a hundred to a few hundred microns. Understanding the propagation of liquid plugs within the bifurcating branches of bronchiole airways is important because their presence in the lungs, and their rupture and break-up, can cause injury to the epithelial cells lining the airway walls as a result of high wall shear stresses. In particular, liquid plug rupture and break-up frequently occurs at airway bifurcations. Until present, however, experimental studies of liquid plugs have generally been restricted to Newtonian fluids that do not reflect the actual pseudoplastic properties of lung mucus. The present work attempts to uncover the propagation, rupture and break-up of mucus-like liquid plugs in the lower generations of the airway tree using microfluidic models. Our approach allows the dynamics of mucus-like plug break-up to be studied in real-time, in a one-to-one in vitro model, as a function of mucus rheology and bronchial tree geometry.

  4. Application of plug-plug technique to ACE experiments for discovery of peptides binding to a larger target protein: a model study of calmodulin-binding fragments selected from a digested mixture of reduced BSA.

    PubMed

    Saito, Kazuki; Nakato, Mamiko; Mizuguchi, Takaaki; Wada, Shinji; Uchimura, Hiromasa; Kataoka, Hiroshi; Yokoyama, Shigeyuki; Hirota, Hiroshi; Kiso, Yoshiaki

    2014-03-01

    To discover peptide ligands that bind to a target protein with a higher molecular mass, a concise screening methodology has been established, by applying a "plug-plug" technique to ACE experiments. Exploratory experiments using three mixed peptides, mastoparan-X, β-endorphin, and oxytocin, as candidates for calmodulin-binding ligands, revealed that the technique not only reduces the consumption of the protein sample, but also increases the flexibility of the experimental conditions, by allowing the use of MS detection in the ACE experiments. With the plug-plug technique, the ACE-MS screening methodology successfully selected calmodulin-binding peptides from a random library with diverse constituents, such as protease digests of BSA. Three peptides with Kd values between 8-147 μM for calmodulin were obtained from a Glu-C endoprotease digest of reduced BSA, although the digest showed more than 70 peaks in its ACE-MS electropherogram. The method established here will be quite useful for the screening of peptide ligands, which have only low affinities due to their flexible chain structures but could potentially provide primary information for designing inhibitors against the target protein. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Forisome performance in artificial sieve tubes.

    PubMed

    Knoblauch, Michael; Stubenrauch, Mike; van Bel, Aart J E; Peters, Winfried S

    2012-08-01

    In the legume phloem, sieve element occlusion (SEO) proteins assemble into Ca(2+)-dependent contractile bodies. These forisomes presumably control phloem transport by forming reversible sieve tube plugs. This function, however, has never been directly demonstrated, and appears questionable as forisomes were reported to be too small to plug sieve tubes, and failed to block flow efficiently in artificial microchannels. Moreover, plugs of SEO-related proteins in Arabidopsis sieve tubes do not affect phloem translocation. We improved existing procedures for forisome isolation and storage, and found that the degree of Ca(2+)-driven deformation that is possible in forisomes of Vicia faba, the standard object of earlier research, has been underestimated substantially. Forisomes deform particularly strongly under reducing conditions and high sugar concentrations, as typically found in sieve tubes. In contrast to our previous inference, Ca(2+)-inducible forisome swelling certainly seems sufficient to plug sieve tubes. This conclusion was supported by 3D-reconstructions of forisome plugs in Canavalia gladiata. For a direct test, we built microfluidics chips with artificial sieve tubes. Using fluorescent dyes to visualize flow, we demonstrated the complete blockage of these biomimetic microtubes by Ca(2+)-induced forisome plugs, and concluded by analogy that forisomes are capable of regulating phloem flow in vivo. © 2012 Blackwell Publishing Ltd.

  6. In vitro sealing of iatrogenic fetal membrane defects by a collagen plug imbued with fibrinogen and plasma.

    PubMed

    Engels, A C; Hoylaerts, M F; Endo, M; Loyen, S; Verbist, G; Manodoro, S; DeKoninck, P; Richter, J; Deprest, J A

    2013-02-01

    We aimed to demonstrate local thrombin generation by fetal membranes, as well as its ability to generate fibrin from fibrinogen concentrate. Furthermore, we aimed to investigate the efficacy of collagen plugs, soaked with plasma and fibrinogen, to seal iatrogenic fetal membrane defects. Thrombin generation by homogenized fetal membranes was measured by calibrated automated thrombography. To identify the coagulation caused by an iatrogenic membrane defect, we analyzed fibrin formation by optical densitometry, upon various concentrations of fibrinogen. The ability of a collagen plug soaked with fibrinogen and plasma was tested in an ex vivo model for its ability to seal an iatrogenic fetal membrane defect. Fetal membrane homogenates potently induced thrombin generation in amniotic fluid and diluted plasma. Upon the addition of fibrinogen concentrate, potent fibrin formation was triggered. Measured by densiometry, fibrin formation was optimal at 1250 µg/mL fibrinogen in combination with 4% plasma. A collagen plug soaked with fibrinogen and plasma sealed an iatrogenic membrane defect about 35% better than collagen plugs without these additives (P = 0.037). These in vitro experiments suggest that the addition of fibrinogen and plasma may enhance the sealing efficacy of collagen plugs in closing iatrogenic fetal membrane defects. © 2013 John Wiley & Sons, Ltd.

  7. The subsidiary gap as a means for improving ignition

    NASA Technical Reports Server (NTRS)

    Gorton, W S

    1920-01-01

    This report was prepared at the Bureau of Standards for the National Advisory Committee for Aeronautics. Additional or subsidiary gaps have frequently been used in jump-spark ignition systems, in order to cause the resumption of sparking in fouled spark plugs. The series gap, to which the greater part of this report is devoted, is a subsidiary gap in the connection between the high tension terminal of the plug and that of the magneto or coil. A brief account is given of the use of this gap up to the present time and also of the statements concerning it which have gained some currency, most of which are shown to be erroneous. The simple theory of the action of the series gap is discussed and a detailed account given of the effect upon the sparking ability of the plug produced by changes in the values of the electrical resistance of the fouling and of the capacities in parallel with the plug and with the magneto or coil. This report presents the results of an investigation into the utility, action, and design of the auxiliary spark gap as a means for insuring freedom from spark plug failure due to fouling, and also to enable the restarting of fouled plugs.

  8. Morphological changes in the seminal receptacle during ovarian development in the speckled swimming crab Arenaeus cribrarius.

    PubMed

    Zara, Fernando Jose; Raggi Pereira, Gerson Rodrigues; Sant'anna, Bruno Sampaio

    2014-08-01

    To understand sperm plug dissolution and spermatophore dehiscence in Portunidae, histological and ultrastructural changes in the seminal receptacle (SR) of Arenaeus cribrarius were investigated during ovarian development. In juvenile females the SR was filled with acid polysaccharides and the dorsal epithelium was stratified. Mated females with rudimentary ovaries showed a large SR filled by a glycoprotein sperm plug. This plug was present until the developing-ovary stage, when spermatophore dehiscence and intense holocrine secretions in the dorsal dense layer occurred. The plug was absent after the intermediate stage, and the SR became flaccid. The secretion produced moved the spermatophores into the ventral region. The modified dorsal epithelium in the transition between the dorsal and ventral regions released acid polysaccharides, which were found among the sperm, by exocytosis. The morphological changes of the SR in A. cribrarius, including the presence of the sperm plug, followed the macroscopic pattern observed in other members of Portunidae, such as blue crabs. However, in this species dissolution of the sperm plug was synchronized with ovarian development and occurred simultaneously with spermatophore dehiscence, showing the evolutionary relationship of the seminal receptacle and the female reproductive system to the storage of spermatophores and spermatozoa. © 2014 Marine Biological Laboratory.

  9. Damage Tolerance Assessment of Friction Pull Plug Welds

    NASA Technical Reports Server (NTRS)

    McGill, Preston; Burkholder, Jonathan

    2012-01-01

    Friction stir welding is a solid state welding process developed and patented by The Welding Institute in Cambridge, England. Friction stir welding has been implemented in the aerospace industry in the fabrication of longitudinal welds in pressurized cryogenic propellant tanks. As the industry looks to implement friction stir welding in circumferential welds in pressurized cryogenic propellant tanks, techniques to close out the termination hole associated with retracting the pin tool are being evaluated. Friction pull plug welding is under development as a one means of closing out the termination hole. A friction pull plug weld placed in a friction stir weld results in a non-homogenous weld joint where the initial weld, plug weld, their respective heat affected zones and the base metal all interact. The welded joint is a composite, plastically deformed material system with a complex residual stress field. In order to address damage tolerance concerns associated with friction plug welds in safety critical structures, such as propellant tanks, nondestructive inspection and proof testing may be required to screen hardware for mission critical defects. The efficacy of the nondestructive evaluation or the proof test is based on an assessment of the critical flaw size in the test or service environments. Test data relating residual strength capability to flaw size in two aluminum alloy friction plug weld configurations is presented.

  10. In-use measurement of activity, energy use, and emissions of a plug-in hybrid electric vehicle.

    PubMed

    Graver, Brandon M; Frey, H Christopher; Choi, Hyung-Wook

    2011-10-15

    Plug-in hybrid electric vehicles (PHEVs) could reduce transportation air emissions and energy use. However, a method is needed for estimating on-road emissions of PHEVs. To develop a framework for quantifying microscale energy use and emissions (EU&E), measurements were conducted on a Toyota Prius retrofitted with a plug-in battery system on eight routes. Measurements were made using the following: (1) a data logger for the hybrid control system; (2) a portable emissions measurement system; and (3) a global positioning system with barometric altimeter. Trends in EU&E are estimated based on vehicle specific power. Energy economy is quantified based on gasoline consumed by the engine and grid energy consumed by the plug-in battery. Emissions from electricity consumption are estimated based on the power generation mix. Fuel use is approximately 30% lower during plug-in battery use. Grid emissions were higher for CO₂, NO(x), SO₂, and PM compared to tailpipe emissions but lower for CO and hydrocarbons. EU&E depends on engine and plug-in battery operation. The use of two energy sources must be addressed in characterizing fuel economy; overall energy economy is 11% lower if including grid energy use than accounting only for fuel consumption.

  11. Versatile Friction Stir Welding/Friction Plug Welding System

    NASA Technical Reports Server (NTRS)

    Carter, Robert

    2006-01-01

    A proposed system of tooling, machinery, and control equipment would be capable of performing any of several friction stir welding (FSW) and friction plug welding (FPW) operations. These operations would include the following: Basic FSW; FSW with automated manipulation of the length of the pin tool in real time [the so-called auto-adjustable pin-tool (APT) capability]; Self-reacting FSW (SRFSW); SR-FSW with APT capability and/or real-time adjustment of the distance between the front and back shoulders; and Friction plug welding (FPW) [more specifically, friction push plug welding] or friction pull plug welding (FPPW) to close out the keyhole of, or to repair, an FSW or SR-FSW weld. Prior FSW and FPW systems have been capable of performing one or two of these operations, but none has thus far been capable of performing all of them. The proposed system would include a common tool that would have APT capability for both basic FSW and SR-FSW. Such a tool was described in Tool for Two Types of Friction Stir Welding (MFS- 31647-1), NASA Tech Briefs, Vol. 30, No. 10 (October 2006), page 70. Going beyond what was reported in the cited previous article, the common tool could be used in conjunction with a plug welding head to perform FPW or FPPW. Alternatively, the plug welding head could be integrated, along with the common tool, into a FSW head that would be capable of all of the aforementioned FSW and FPW operations. Any FSW or FPW operation could be performed under any combination of position and/or force control.

  12. 2014/2219 Tri-Point Crack Analysis

    NASA Technical Reports Server (NTRS)

    Horton, Karla Renee

    2011-01-01

    Friction stir welding (FSW) is a solid state welding process with potential advantages for aerospace and automotive industries dealing with light alloys. Self-reacting friction stir welding (SR-FSW) is one variation of the FSW process being developed at the National Aeronautics and Space Administration (NASA) for use in the fabrication of propellant tanks. Friction plug welding is used to seal the exit hole that remains in a circumferential SR-FSW. The objective of this study was to evaluate the deformation response at the tips of cracks located in the heat affected zone of friction plug welds and to study the fracture behavior of welds with defects in the form of fatigue cracks. The study used existing 2014-T6 to 2219-T87 self-reacting friction stir weld panels with 2219-T87 friction plug welds. Electro-discharge machined (EDM) notches were machined into the heat affected zone of the plug at the plug-to-base metal interface. Samples were then cycled to generate a fatigue crack emanating from the notch. After the fatigue crack reached a pre-defined length, a speckle pattern was applied and the ARAMIS system (a three dimensional imaging correlation system) was used to measure the deformations at the crack tip under a sequence of loads. Testing was conducted at ambient laboratory conditions. Fracture data from the testing was analyzed to evaluate residual strength capability of the panel as a function of flaw size. ARAMIS strain data was evaluated to examine strain and deformation patterns that develop around the crack tip and at the plug/weld interfaces. Four samples were used in this study, with three samples in a post-weld heat treated condition. Three samples contained large diameter plugs (M5) and one sample contained a small diameter plug (M3). Two samples were 4 inches in width and two samples were 8.5 inches in width. All samples failed through the precrack with residual strengths ranging from 37 ksi to 42 ksi.

  13. System for Packaging Planetary Samples for Return to Earth

    NASA Technical Reports Server (NTRS)

    Badescu, Mircea; Bar-Cohen, Yoseph; Backes, paul G.; Sherrit, Stewart; Bao, Xiaoqi; Scott, James S.

    2010-01-01

    A system is proposed for packaging material samples on a remote planet (especially Mars) in sealed sample tubes in preparation for later return to Earth. The sample tubes (Figure 1) would comprise (1) tubes initially having open tops and closed bottoms; (2) small, bellows-like collapsible bodies inside the tubes at their bottoms; and (3) plugs to be eventually used to close the tops of the tubes. The top inner surface of each tube would be coated with solder. The side of each plug, which would fit snugly into a tube, would feature a solder-filled ring groove. The system would include equipment for storing, manipulating, filling, and sealing the tubes. The containerization system (see Figure 2) will be organized in stations and will include: the storage station, the loading station, and the heating station. These stations can be structured in circular or linear pattern to minimize the manipulator complexity, allowing for compact design and mass efficiency. The manipulation of the sample tube between stations is done by a simple manipulator arm. The storage station contains the unloaded sample tubes and the plugs before sealing as well as the sealed sample tubes with samples after loading and sealing. The chambers at the storage station also allow for plug insertion into the sample tube. At the loading station the sample is poured or inserted into the sample tube and then the tube is topped off. At the heating station the plug is heated so the solder ring melts and seals the plug to the sample tube. The process is performed as follows: Each tube is filled or slightly overfilled with sample material and the excess sample material is wiped off the top. Then, the plug is inserted into the top section of the tube packing the sample material against the collapsible bellowslike body allowing the accommodation of the sample volume. The plug and the top of the tube are heated momentarily to melt the solder in order to seal the tube.

  14. Ceramic Borehole Seals for Nuclear Waste Disposal Applications

    NASA Astrophysics Data System (ADS)

    Lowry, B.; Coates, K.; Wohletz, K.; Dunn, S.; Patera, E.; Duguid, A.; Arnold, B.; Zyvoloski, G.; Groven, L.; Kuramyssova, K.

    2015-12-01

    Sealing plugs are critical features of the deep borehole system design. They serve as structural platforms to bear the weight of the backfill column, and as seals through their low fluid permeability and bond to the borehole or casing wall. High hydrostatic and lithostatic pressures, high mineral content water, and elevated temperature due to the waste packages and geothermal gradient challenge the long term performance of seal materials. Deep borehole nuclear waste disposal faces the added requirement of assuring performance for thousands of years in large boreholes, requiring very long term chemical and physical stability. A high performance plug system is being developed which capitalizes on the energy of solid phase reactions to form a ceramic plug in-situ. Thermites are a family of self-oxidized metal/oxide reactions with very high energy content and the ability to react under water. When combined with engineered additives the product exhibits attractive structural, sealing, and corrosion properties. In the initial phase of this research, exploratory and scaled tests demonstrated formulations that achieved controlled, fine grained, homogeneous, net shape plugs composed predominantly of ceramic material. Laboratory experiments produced plug cores with confined fluid permeability as low as 100 mDarcy, compressive strength as high as 70 MPa (three times the strength of conventional well cement), with the inherent corrosion resistance and service temperature of ceramic matrices. Numerical thermal and thermal/structural analyses predicted the in-situ thermal performance of the reacted plugs, showing that they cooled to ambient temperature (and design strength) within 24 to 48 hours. The current development effort is refining the reactant formulations to achieve desired performance characteristics, developing the system design and emplacement processes to be compatible with conventional well service practices, and understanding the thermal, fluid, and structural effects the plug will have on surrounding media. This paper will report on the state of the development effort and plans for a field demonstration in early 2016 in a cased well with traditional plug seal and strength measurements.

  15. Rapid fibrin plug formation within cutaneous ablative fractional CO2 laser lesions.

    PubMed

    Kositratna, Garuna; Evers, Michael; Sajjadi, Amir; Manstein, Dieter

    2016-02-01

    Ablative fractional laser procedures have been shown to facilitate topical drug delivery into the skin. Past studies have mainly used ex vivo models to demonstrate enhanced drug delivery and in vivo studies have investigated laser created channels over a time course of days and weeks rather than within the first few minutes and hours after exposures. We have noticed rapid in vivo fibrin plug formation within ablative fractional laser lesions impairing passage through the laser created channels. In vivo laser exposures were performed in a porcine model. A fractional CO2 laser (AcuPulse™ system, AcuScan 120™ handpiece, Lumenis, Inc., Yokneam, Israel) was programmed in quasi-continuous wave (QCW) mode, at 40W, 50 mJ per pulse, 5% coverage, nominal 120 µm spot size, 8 × 8 mm square pattern, 169 MTZs per scan. Six millimeters punch biopsies were procured at 0, 2, 5, 10, 15, 30, 60, 90 minutes after completion of each scan, then fixed in 10% formalin. 12 repeats were performed of each time point. Skin samples were processed for serial vertically cut paraffin sections (5 μm collected every 25 μm) then H&E and special immunohistochemistry staining for fibrin and platelet. Dimensions of Microscopic Treatment Zones (MTZs) and extent of fibrin plug were assessed and quantified histologically. Ex vivo laser exposures of the identical laser parameter were performed on porcine and human skin at different storage conditions. Histology procured at various predetermined time intervals after in vivo fractional CO2 laser exposures revealed a rapidly forming fibrin plug initiating at the bottom of the MTZ lesions. At longer time intervals, the fibrin plug was extending towards the superficial sections. Within the first 5 minutes, more than 25% length of the entire laser-ablated channel was filled with a fibrin plug. With increased time intervals, the cavity was progressively filled with a fibrin plug. At 90 minutes, more than 90% length of the entire laser-ablated channel was occluded. Ex vivo exposures failed to produce any significant fibrin plug formation. The current study has demonstrated rapid fibrin plug formation after ablative fractional laser procedures. It was shown that the passage through laser created pathways is critically time dependent for in vivo exposures. In contrast, ex vivo exposures do not exhibit such time dependent passage capacity. In particular, drug, substance, and cell delivery studies for ablative fractional laser treatments should take early fibrin plug formation into consideration and further investigate the impact on transdermal delivery. © 2015 Wiley Periodicals, Inc.

  16. Critical Propulsion and Noise reduction Technologies for Future Commercial Subsonic Engines. Area of Interest 14.3: Separate Flow Exhaust System Noise

    NASA Technical Reports Server (NTRS)

    Janardan, B. A.; Hoff, G. E.; Barter, J. W.; Brausch, J. F.; Gliebe, P. R.; Coffin, R. S.; Martens, S.; Delaney, B. R.; Dalton, W. N.; Mengle, V. G.

    2000-01-01

    This presentation discusses: Project Objectives, Approach and Goal; Baseline Nozzles and Test Cycle Definition; Repeatability and Baseline Nozzle Results; Noise Reduction Concepts; Noise Reduction Tests Configurations of BPR=5 Internal Plug Nozzle adn Acoustic Results; Noise Reduction Test Configurations of BPR=5 External Plug Nozzle and Acoustic Results; and Noise Reduction Tests Configurations of BPR=8 External Plug Nozzle and Acoustic Results.

  17. MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO AN MTR BEAM HOLE. ONE MAN CHECKS RADIATION LEVEL AT THE END OF THE UNIVERSAL COFFIN, WHILE ANOTHER USES TOOL TO INSERT PLUG INTO HOLE THROUGH COFFIN. MEN WEAR "ANTI-C" (ANTI-CONTAMINATION) CLOTHING. INL NEGATIVE NO. 6198. R.G. Larsen, Photographer, 6/27/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  18. Hybrid and Plug-In Electric Vehicles (Spanish Version); Clean Cities, Energy Efficiency & Renewable Energy (EERE) (in Spanish)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    This is a Spanish-language brochure about hybrid and plug-in electric vehicles, which use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. These vehicles can be divided into three categories: hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs), all-electric vehicles (EVs). Together, they have great potential to cut U.S. petroleum use and vehicle emissions.

  19. City of Las Vegas Plug-in Hybrid Electric Vehicle Demonstration Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2013-12-31

    The City of Las Vegas was awarded Department of Energy (DOE) project funding in 2009, for the City of Las Vegas Plug-in Hybrid Electric Vehicle Demonstration Program. This project allowed the City of Las Vegas to purchase electric and plug-in hybrid electric vehicles and associated electric vehicle charging infrastructure. The City anticipated the electric vehicles having lower overall operating costs and emissions similar to traditional and hybrid vehicles.

  20. Multiple-port valve

    DOEpatents

    Doody, Thomas J.

    1978-08-22

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable wih one or more of a plurality of secondary conduits fitted into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits.

  1. Plug nozzles: The ultimate customer driven propulsion system

    NASA Technical Reports Server (NTRS)

    Aukerman, Carl A.

    1991-01-01

    This paper presents the results of a study applying the plug cluster nozzle concept to the propulsion system for a typical lunar excursion vehicle. Primary attention for the design criteria is given to user defined factors such as reliability, low volume, and ease of propulsion system development. Total thrust and specific impulse are held constant in the study while other parameters are explored to minimize the design chamber pressure. A brief history of the plug nozzle concept is included to point out the advanced level of technology of the concept and the feasibility of exploiting the variables considered in this study. The plug cluster concept looks very promising as a candidate for consideration for the ultimate customer driven propulsion system.

  2. Effects of external stream flow and afterbody variations on the performance of a plug nozzle

    NASA Technical Reports Server (NTRS)

    Salmi, R J; Cortright, E M , Jr

    1956-01-01

    The off-design operation of an isentropic plug nozzle designed for a jet pressure ratio of 15 was investigated experimentally at subsonic Mach numbers up to 0.9 and jet pressure ratios up to 5. When installed in a cylindrical nacelle with a sharp turn at the nozzle lip, the interaction of the jet and the external stream produced low pressures on the base formed by the high lip angle. These low pressures increased the nacelle drag and caused an overexpansion of the jet, which resulted in lower pressures on the plug and, hence, reduced thrust. With a boattail ahead of the plug nozzle, the base pressures were increased and the jet overexpansion significantly reduced.

  3. Plug nozzles - The ultimate customer driven propulsion system. [applied to manned lunar and Martian landers

    NASA Technical Reports Server (NTRS)

    Aukerman, Carl A.

    1991-01-01

    This paper presents the results of a study applying the plug cluster nozzle concept to the propulsion system for a typical lunar excursion vehicle. Primary attention for the design criteria is given to user defined factors such as reliability, low volume, and ease of propulsion system development. Total thrust and specific impulse are held constant in the study while other parameters are explored to minimize the design chamber pressure. A brief history of the plug nozzle concept is included to point out the advanced level of technology of the concept and the feasibility of exploiting the variables considered in the study. The plug cluster concept looks very promising as a candidate for consideration for the ultimate customer driven propulsion system.

  4. Toyota Prius Plug-In HEV: A Plug-In Hybrid Electric Car in NREL's Advanced Technology Vehicle Fleet (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This fact sheet highlights the Toyota Prius plug-in HEV, a plug-in hybrid electric car in the advanced technology vehicle fleet at the National Renewable Energy Laboratory (NREL). In partnership with the University of Colorado, NREL uses the vehicle for grid-integration studies and for testing new hardware and charge-management algorithms. NREL's advanced technology vehicle fleet features promising technologies to increase efficiency and reduce emissions without sacrificing safety or comfort. The fleet serves as a technology showcase, helping visitors learn about innovative vehicles that are available today or are in development. Vehicles in the fleet are representative of current, advanced, prototype, andmore » emerging technologies.« less

  5. APPARATUS FOR MELTING AND POURING METAL

    DOEpatents

    Harris, F.A.

    1958-02-25

    This patent relates to a crucible for melting and pouring a metal under controlled atmospheric conditions. The crucible has a frangible plug in the bottom and a retaining device to prevent the entrance of the broken portions of the plug into the mold without interfering with the flow of the melt. After the charge has been melted, a knockout rod is lowered through the charge and forced against the frangible plug sufficiently to break off the closure disk along a previously scored line. The disk drops onto a retaining grid large enough to permit the flow of metal around the disk and into the mold below. Thts arrangement elimnates the entry of broken portions of the plug into the mold, thereby elimnating a common cause of imperfect castings.

  6. Robust small area prediction for counts.

    PubMed

    Tzavidis, Nikos; Ranalli, M Giovanna; Salvati, Nicola; Dreassi, Emanuela; Chambers, Ray

    2015-06-01

    A new semiparametric approach to model-based small area prediction for counts is proposed and used for estimating the average number of visits to physicians for Health Districts in Central Italy. The proposed small area predictor can be viewed as an outlier robust alternative to the more commonly used empirical plug-in predictor that is based on a Poisson generalized linear mixed model with Gaussian random effects. Results from the real data application and from a simulation experiment confirm that the proposed small area predictor has good robustness properties and in some cases can be more efficient than alternative small area approaches. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Effects of gravity, inertia, and surfactant on steady plug propagation in a two-dimensional channel

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Fujioka, H.; Grotberg, J. B.

    2007-08-01

    Liquid plugs may form in pulmonary airways during the process of liquid instillation or removal in many clinical treatments. Studies have shown that the effectiveness of these treatments may depend on how liquids distribute in the lung. Better understanding of the fundamental fluid mechanics of liquid plug transport will facilitate treatment strategies. In this paper, we develop a numerical model of steady plug propagation driven by gravity and pressure in a two-dimensional liquid-lined channel oriented at an angle α with respect to gravity. We investigate the effects of gravity through the Bond number, Bo, and α; the plug propagation speed through the capillary number, Ca, or the Reynolds number, Re; the plug length LP, and the surfactant concentration C0. Without gravity, i.e., Bo =0, the plug is symmetric, and there are two regimes for the flow: two wall layers and two trapped vortices in the core. There is no flow interaction between the upper and lower half plug domains. When Bo ≠0 and α ≠0, π, fluid is found to flow from the upper precursor film, through the core and into the lower trailing film. Then the number of vortices can be zero, one, or two, depending on the flow parameters. The vortices have stagnation points on the interface when C0=0, however when the surfactant is present (C0>0), the vortices detach from the interface and create saddle points inside the core. The front meniscus develops a capillary surface wave extending into the precursor film. This is where the film is thinnest and thus the wall shear stress is highest, as high as ˜100dyn /cm2 in adult airways, which indicates a significant risk of pulmonary airway epithelial cell damage. Adding surfactant can decrease the peak magnitude of the shear stress, thus reducing the risk of cell damage. The prebifurcation asymmetry of the plug is quantified by the volume ratio, Vr, defined as the ratio of the liquid above to that below the center line of the channel. Vr is found to increase with LP, Ca, Re, and C0, while it decreases with Bo. The total mass left behind in the trailing films increases with Bo for any α at α >2π/5, Ca and α for any value of Bo >0.

  8. Ureteric Embolization for Lower Urinary Tract Fistulae: Use of Two Amplatzer Vascular Plugs and N-Butyl Cyanoacrylate Employing the 'Sandwich' Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saad, Wael E. A., E-mail: ws6r@virginia.edu; Kalagher, S.; Turba, U. C.

    2013-08-01

    PurposeThis study describes and evaluated the effectiveness of occluding distal ureters in the clinical setting of urinary vaginal (vesicovaginal or enterovesicovaginal) fistulae utilizing a new technique which combines Amplatzer vascular plugs and N-butyl cyanoacrylate.MaterialsThis is a retrospective study (January 2007-December 2010) of patients with urinary-vaginal fistulae undergoing distal ureter embolization utilizing an Amplatzer- N-butyl cyanoacrylate-Amplatzer sandwich technique. An 8-12-mm type-I or type-II Amplatzer vascular plug was delivered using the sheath and deployed in the ureter distal to the pelvic brim. Instillation of 0.8-1.5 cc of N-butyl cyanoacrylate into ureter proximal to the Amplatzer plug was performed. This was followed bymore » another set of 8-12-mm type-I or type-II Amplatzer vascular plugs in a technique referred to as the 'sandwich technique.'ResultsFive ureters in three patients were occluded utilizing the above-described technique during the 4-year study period. Mean maximum size Amplatzer used per ureter was 10.8 mm (range, 8-12). One ureter required three Amplatzer plugs and the rest required two. Two patients (3 ureters) were clinically successful with complete resolution of symptoms in 36-48 h. The third patient (2 ureters) was partly successful and required a second Amplatzer- N-butyl cyanoacrylate sandwich technique embolization. The mean clinical follow-up was 11.3 months (range, 1.7-29.2).ConclusionsThe Amplatzer- N-butyl cyanoacrylate-Amplatzer sandwich technique for occluding the distal ureter is safe and effective with a quick (probably due to the N-butyl cyanoacrylate) and durable (probably due to the Amplatzer plugs) clinical response.« less

  9. Domain activities of PapC usher reveal the mechanism of action of an Escherichia coli molecular machine.

    PubMed

    Volkan, Ender; Ford, Bradley A; Pinkner, Jerome S; Dodson, Karen W; Henderson, Nadine S; Thanassi, David G; Waksman, Gabriel; Hultgren, Scott J

    2012-06-12

    P pili are prototypical chaperone-usher pathway-assembled pili used by Gram-negative bacteria to adhere to host tissues. The PapC usher contains five functional domains: a transmembrane β-barrel, a β-sandwich Plug, an N-terminal (periplasmic) domain (NTD), and two C-terminal (periplasmic) domains, CTD1 and CTD2. Here, we delineated usher domain interactions between themselves and with chaperone-subunit complexes and showed that overexpression of individual usher domains inhibits pilus assembly. Prior work revealed that the Plug domain occludes the pore of the transmembrane domain of a solitary usher, but the chaperone-adhesin-bound usher has its Plug displaced from the pore, adjacent to the NTD. We demonstrate an interaction between the NTD and Plug domains that suggests a biophysical basis for usher gating. Furthermore, we found that the NTD exhibits high-affinity binding to the chaperone-adhesin (PapDG) complex and low-affinity binding to the major tip subunit PapE (PapDE). We also demonstrate that CTD2 binds with lower affinity to all tested chaperone-subunit complexes except for the chaperone-terminator subunit (PapDH) and has a catalytic role in dissociating the NTD-PapDG complex, suggesting an interplay between recruitment to the NTD and transfer to CTD2 during pilus initiation. The Plug domain and the NTD-Plug complex bound all of the chaperone-subunit complexes tested including PapDH, suggesting that the Plug actively recruits chaperone-subunit complexes to the usher and is the sole recruiter of PapDH. Overall, our studies reveal the cooperative, active roles played by periplasmic domains of the usher to initiate, grow, and terminate a prototypical chaperone-usher pathway pilus.

  10. Secure fixation of femoral bone plug with a suspensory button in anatomical anterior cruciate ligament reconstruction with bone-patellar tendon-bone graft

    PubMed Central

    TAKETOMI, SHUJI; INUI, HIROSHI; NAKAMURA, KENSUKE; YAMAGAMI, RYOTA; TAHARA, KEITARO; SANADA, TAKAKI; MASUDA, HIRONARI; TANAKA, SAKAE; NAKAGAWA, TAKUMI

    2015-01-01

    Purpose the efficacy and safety of using a suspensory button for femoral fixation in anatomical anterior cruciate ligament (ACL) reconstruction with bone-patellar tendon-bone (BPTB) graft have not been established. The purpose of the current study was to evaluate bone plug integration onto the femoral socket and migration of the bone plug and the EndoButton (EB) (Smith & Nephew, Andover, MA, USA) after rectangular tunnel ACL reconstruction with BPTB autograft. Methods thirty-four patients who underwent anatomical rectangular ACL reconstruction with BPTB graft using EB for femoral fixation and in whom three-dimensional (3D) computed tomography (CT) was performed one week and one year after surgery were included in this study. Bone plug integration onto the femoral socket, bone plug migration, soft tissue interposition, EB migration and EB rotation were evaluated on 3D CT. The clinical outcome was also assessed and correlated with the imaging outcomes. Results the bone plug was integrated onto the femoral socket in all cases. The incidence of bone plug migration, soft tissue interposition, EB migration and EB rotation was 15, 15, 9 and 56%, respectively. No significant association was observed between the imaging outcomes. The postoperative mean Lysholm score was 97.1 ± 5.0 points. The postoperative side-to-side difference, evaluated using a KT-2000 arthrometer, averaged 0.5 ± 1.3 mm. There were no complications associated with EB use. Imaging outcomes did not affect the postoperative KT side-to-side difference. Conclusions the EB is considered a reliable device for femoral fixation in anatomical rectangular tunnel ACL reconstruction with BPTB autograft. Level of evidence Level IV, therapeutic case series. PMID:26889465

  11. Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia.

    PubMed

    Tau, Noam; Atar, Eliyahu; Mei-Zahav, Meir; Bachar, Gil N; Dagan, Tamir; Birk, Einat; Bruckheimer, Elchanan

    2016-08-01

    Coil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia. The study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004-2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher's exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05. 16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4-18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413). The use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

  12. The TonB-dependent Transporter FhuA in Planar Lipid Bilayers: partial exit of its plug from the barrel

    PubMed Central

    Udho, Eshwar; Jakes, Karen S.; Finkelstein, Alan

    2012-01-01

    TonB-dependent transporters (TBDTs), which transport iron-chelating siderophores and vitamin B12 across the outer membrane of gram negative bacteria, share a conserved architecture of a 22-stranded beta-barrel with an amino-terminal plug domain occluding the barrel. We previously reported that we could induce TBDTs to reversibly open in planar lipid bilayers via the use of urea and that these channels were responsive to physiological concentrations of ligands. Here we report that in the presence of urea, trypsin can cleave the amino-terminal 67 residues of the plug of the TonB-dependent transporter FhuA, as assessed by gel shift and mass spectrometry assays. On the bilayer, trypsin treatment in the presence of urea resulted in the induced conductance no longer being reversed upon removal of urea, suggesting that urea opens intact FhuA channels by pulling the plug at least partly out of the barrel, and that removal of the urea then allows reinsertion of the plug into the barrel. When expressed separately, the FhuA plug domain was found to be a mostly unfolded structure that was able to occlude isolated FhuA beta-barrels inserted into the membrane. Thus, although folded in the barrel, the plug need not be folded upon exiting the barrel. The rate of insertion of the beta-barrels into the membrane was tremendously increased in the presence of an osmotic gradient provided by either urea or glycerol. Negative staining electron microscopy showed that FhuA in a detergent solution formed vesicles, thus explaining why an osmotic gradient promoted the insertion of FhuA into membranes. PMID:22846061

  13. Plug and Play PV Systems for American Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoepfner, Christian

    2016-12-22

    The core objectives of the Plug & Play PV Systems Project were to develop a PV system that can be installed on a residential rooftop for less than $1.50/W in 2020, and in less than 10 hours (from point of purchase to commissioning). The Fraunhofer CSE team’s approach to this challenge involved a holistic approach to system design – hardware and software – that make Plug & Play PV systems: • Quick, easy, and safe to install • Easy to demonstrate as code compliant • Permitted, inspected, and interconnected via an electronic process Throughout the three years of work duringmore » this Department of Energy SunShot funded project, the team engaged in a substantive way with inspectional services departments and utilities, manufacturers, installers, and distributors. We received iterative feedback on the system design and on ideas for how such systems can be commercialized. This ultimately led us to conceiving of Plug & Play PV Systems as a framework, with a variety of components compatible with the Plug & Play PV approach, including string or microinverters, conventional modules or emerging lightweight modules. The framework enables a broad group of manufacturers to participate in taking Plug & Play PV Systems to market, and increases the market size for such systems. Key aspects of the development effort centered on the system hardware and associated engineering work, the development of a Plug & Play PV Server to enable the electronic permitting, inspection and interconnection process, understanding the details of code compliance and, on occasion, supporting applications for modifications to the code to allow lightweight modules, for example. We have published a number of papers on our testing and assessment of novel technologies (e.g., adhered lightweight modules) and on the electronic architecture.« less

  14. A comparison of avian communities and habitat characteristics in floodplain forests associated with valley plugs and unchannelized streams

    USGS Publications Warehouse

    Pierce, Aaron R.; King, Sammy L.

    2011-01-01

    Channelization of streams associated with floodplain forested wetlands has occurred extensively throughout the world and specifically in the southeastern United States. Channelization of fluvial systems alters the hydrologic and sedimentation processes that sustain these systems. In western Tennessee, channelization and past land-use practices have caused drastic geomorphic and hydrologic changes, resulting in altered habitat conditions that may affect avian communities. The objective of this study was to determine if there were differences in avian communities utilizing floodplain forests along unchannelized streams compared to channelized streams with valley plugs, areas where sediment has completely filled the channel. During point count surveys, 58 bird species were observed at unchannelized sites and 60 species were observed at valley plug sites. Species associated with baldcypress-tupelo (Taxodium-Nyssa) swamps (e.g. Great Egret (Ardea albus) and Black-crowned Night Heron (Nycticorax nycticorax)) and mature hardwood forests with open midstories (e.g. Eastern Wood-Pewee (Contopus virens), Yellow-throated Vireo (Vireo flavifrons), Cerulean Warbler (Dendroica cerulea) and Scarlet Tanager (Piranga olivacea)) were either only found at unchannelized sites or were more abundant at unchannelized sites. Conversely, species associated with open and early successional habitats (e.g. Tree Swallow (Tachycineta bicolor), Northern Mockingbird (Mimus polyglottos) and Blue Grosbeak (Passerina caerulea)) were either only found at valley plug sites or were more abundant at valley plug sites. Results of habitat modelling suggest that the habitat characteristics of floodplain forests at unchannelized sites are more suitable for Neotropical migrant bird species of conservation concern in the region than at valley plug sites. This study, in combination with previous research, demonstrates the ecological impacts of valley plugs span across abiotic and biotic processes and tropic levels.

  15. Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tau, Noam, E-mail: taunoam@gmail.com; Atar, Eliyahu; Mei-Zahav, Meir

    PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both),more » and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.« less

  16. Bacillus amyloliquefaciens L-S60 Reforms the Rhizosphere Bacterial Community and Improves Growth Conditions in Cucumber Plug Seedling

    PubMed Central

    Qin, Yuxuan; Shang, Qingmao; Zhang, Ying; Li, Pinglan; Chai, Yunrong

    2017-01-01

    Vegetable plug seedling has become the most important way to produce vegetable seedlings in China. This seedling method can significantly improve the quality and yield of vegetables compared to conventional methods. In the process of plug seedling, chemical fertilizers or pesticides are often used to improve the yield of the seedlings albeit with increasing concerns. Meanwhile, little is known about the impact of beneficial bacteria on the rhizosphere microbiota and the growth conditions of vegetables during plug seedling. In this study, we applied a culture-independent next-generation sequencing-based approach and investigated the impact of a plant beneficial bacterium, Bacillus amyloliquefaciens L-S60, on the composition and dynamics of rhizosphere microbiota and the growth conditions of cucumbers during plug seedling. Our results showed that application of L-S60 significantly altered the structure of the bacterial community associated with the cucumber seedling; presence of beneficial rhizosphere species such as Bacillus, Rhodanobacter, Paenibacillus, Pseudomonas, Nonomuraea, and Agrobacterium was higher upon L-S60 treatment than in the control group. We also measured the impact of L-S60 application on the physiological properties of the cucumber seedlings as well as the availability of main mineral elements in the seedling at different time points during the plug seedling. Results from those measurements indicated that L-S60 application promoted growth conditions of cucumber seedlings and that more available mineral elements were detected in the cucumber seedlings from the L-S60 treated group than from the control group. The findings in this study provided evidence for the beneficial effects of plant growth-promoting rhizosphere bacteria on the bacterial community composition and growth conditions of the vegetables during plug seedling. PMID:29312278

  17. Proposal for probing energy transfer pathway by single-molecule pump-dump experiment.

    PubMed

    Tao, Ming-Jie; Ai, Qing; Deng, Fu-Guo; Cheng, Yuan-Chung

    2016-06-09

    The structure of Fenna-Matthews-Olson (FMO) light-harvesting complex had long been recognized as containing seven bacteriochlorophyll (BChl) molecules. Recently, an additional BChl molecule was discovered in the crystal structure of the FMO complex, which may serve as a link between baseplate and the remaining seven molecules. Here, we investigate excitation energy transfer (EET) process by simulating single-molecule pump-dump experiment in the eight-molecules complex. We adopt the coherent modified Redfield theory and non-Markovian quantum jump method to simulate EET dynamics. This scheme provides a practical approach of detecting the realistic EET pathway in BChl complexes with currently available experimental technology. And it may assist optimizing design of artificial light-harvesting devices.

  18. Proposal for probing energy transfer pathway by single-molecule pump-dump experiment

    NASA Astrophysics Data System (ADS)

    Tao, Ming-Jie; Ai, Qing; Deng, Fu-Guo; Cheng, Yuan-Chung

    2016-06-01

    The structure of Fenna-Matthews-Olson (FMO) light-harvesting complex had long been recognized as containing seven bacteriochlorophyll (BChl) molecules. Recently, an additional BChl molecule was discovered in the crystal structure of the FMO complex, which may serve as a link between baseplate and the remaining seven molecules. Here, we investigate excitation energy transfer (EET) process by simulating single-molecule pump-dump experiment in the eight-molecules complex. We adopt the coherent modified Redfield theory and non-Markovian quantum jump method to simulate EET dynamics. This scheme provides a practical approach of detecting the realistic EET pathway in BChl complexes with currently available experimental technology. And it may assist optimizing design of artificial light-harvesting devices.

  19. Proposal for probing energy transfer pathway by single-molecule pump-dump experiment

    PubMed Central

    Tao, Ming-Jie; Ai, Qing; Deng, Fu-Guo; Cheng, Yuan-Chung

    2016-01-01

    The structure of Fenna-Matthews-Olson (FMO) light-harvesting complex had long been recognized as containing seven bacteriochlorophyll (BChl) molecules. Recently, an additional BChl molecule was discovered in the crystal structure of the FMO complex, which may serve as a link between baseplate and the remaining seven molecules. Here, we investigate excitation energy transfer (EET) process by simulating single-molecule pump-dump experiment in the eight-molecules complex. We adopt the coherent modified Redfield theory and non-Markovian quantum jump method to simulate EET dynamics. This scheme provides a practical approach of detecting the realistic EET pathway in BChl complexes with currently available experimental technology. And it may assist optimizing design of artificial light-harvesting devices. PMID:27277702

  20. Piston manometer as an absolute standard for vacuum gage calibration in the range 10 to 700 microtorr

    NASA Technical Reports Server (NTRS)

    Warshawsky, I.

    1972-01-01

    Total pressure in a calibration chamber is determined by measuring the force on a disk suspended in an orifice in the baseplate of the chamber. The disk forms a narrow annular gap with the orifice. A continuous flow of calibration gas passes through the chamber and annulus to a downstream pumping system. The ratio of pressures on the two faces of the disk exceeds 100:1, so that chamber pressure is substantially equal to the product of disk area and net force on the disk. This force is measured with an electrodynamometer that can be calibrated in situ with dead weights. Probable error in pressure measurement is plus or minus (0.5 microtorr + 0.6 percent).

  1. Method of forming a spacer for field emission flat panel displays

    DOEpatents

    Bernhardt, A.F.; Contolini, R.J.

    1997-08-19

    Spacers are disclosed for applications such as field emission flat panel displays and vacuum microelectronics, and which involves the application of aerogel/xerogel technology to the formation of the spacer. In a preferred approach the method uses a mold and mold release agent wherein the gel precursor is a liquid which can be applied to the mold filling holes which expose the substrate (either the baseplate or the faceplate). A release agent is applied to the mold prior to precursor application to ease removal of the mold after formation of the dielectric spacer. The shrinkage of the gel during solvent extraction also improves mold removal. The final spacer material is a good dielectric, such as silica, secured to the substrate. 3 figs.

  2. Forster energy transfer in chlorosomes of green photosynthetic bacteria

    NASA Technical Reports Server (NTRS)

    Causgrove, T. P.; Brune, D. C.; Blankenship, R. E.

    1992-01-01

    Energy transfer properties of whole cells and chlorosome antenna complexes isolated from the green sulfur bacteria Chlorobium limicola (containing bacteriochlorophyll c), Chlorobium vibrioforme (containing bacteriochlorophyll d) and Pelodictyon phaeoclathratiforme (containing bacteriochlorophyll e) were measured. The spectral overlap of the major chlorosome pigment (bacteriochlorophyll c, d or, e) with the bacteriochlorophyll a B795 chlorosome baseplate pigment is greatest for bacteriochlorophyll c and smallest for bacteriochlorophyll e. The absorbance and fluorescence spectra of isolated chlorosomes were measured, fitted to gaussian curves and the overlap factors with B795 calculated. Energy transfer times from the bacteriochlorophyll c, d or e to B795 were measured in whole cells and the results interpreted in terms of the Forster theory of energy transfer.

  3. Method of forming a spacer for field emission flat panel displays

    DOEpatents

    Bernhardt, Anthony F.; Contolini, Robert J.

    1997-01-01

    Spacers for applications such as field emission flat panel displays and vacuum microelectronics, and which involves the application of aerogel/xerogel technology to the formation of the spacer. In a preferred approach the method uses a mold and mold release agent wherein the gel precursor is a liquid which can be applied to the mold filling holes which expose the substrate (either the baseplate or the faceplate). A release agent is applied to the mold prior to precursor application to ease removal of the mold after formation of the dielectric spacer. The shrinkage of the gel during solvent extraction also improves mold removal. The final spacer material is a good dielectric, such as silica, secured to the substrate.

  4. The origin of lunar mascons - Analysis of the Bouguer gravity associated with Grimaldi

    NASA Technical Reports Server (NTRS)

    Phillips, R. J.; Dvorak, J.

    1981-01-01

    Grimaldi is a relatively small multi-ringed basin located on the western limb of the moon. Spacecraft free-air gravity data reveal a mascon associated with the inner ring of this structure, and the topographic correction to the local lunar gravity field indicates a maximum Bouguer anomaly of +90 milligals at an altitude of 70 kilometers. Approximately 20% of this positive Bouguer anomaly can be attributed to the mare material lying within the inner ring of this basin. From a consideration of the Bouguer gravity and structure of large lunar craters comparable in size to the central basin of Grimaldi, it is suggested that the remaining positive Bouguer anomaly is due to a centrally uplifted plug of lunar mantle material. The uplift was caused by inward crustal collapse which also resulted in the formation of the concentric outer scarp of Grimaldi. In addition, an annulus of low density material, probably a combination of ejecta and in situ breccia, is required to fully reproduce the Bouguer gravity signature across this basin. It is proposed that Grimaldi supplies a critical test in the theory of mascon formation: crustal collapse by ring faulting and central uplift to depths of the crust-mantle boundary are requisites

  5. Three-dimensional preservation of cellular and subcellular structures suggests 1.6 billion-year-old crown-group red algae

    PubMed Central

    Bengtson, Stefan; Sallstedt, Therese; Belivanova, Veneta; Whitehouse, Martin

    2017-01-01

    The ~1.6 Ga Tirohan Dolomite of the Lower Vindhyan in central India contains phosphatized stromatolitic microbialites. We report from there uniquely well-preserved fossils interpreted as probable crown-group rhodophytes (red algae). The filamentous form Rafatazmia chitrakootensis n. gen, n. sp. has uniserial rows of large cells and grows through diffusely distributed septation. Each cell has a centrally suspended, conspicuous rhomboidal disk interpreted as a pyrenoid. The septa between the cells have central structures that may represent pit connections and pit plugs. Another filamentous form, Denaricion mendax n. gen., n. sp., has coin-like cells reminiscent of those in large sulfur-oxidizing bacteria but much more recalcitrant than the liquid-vacuole-filled cells of the latter. There are also resemblances with oscillatoriacean cyanobacteria, although cell volumes in the latter are much smaller. The wider affinities of Denaricion are uncertain. Ramathallus lobatus n. gen., n. sp. is a lobate sessile alga with pseudoparenchymatous thallus, “cell fountains,” and apical growth, suggesting florideophycean affinity. If these inferences are correct, Rafatazmia and Ramathallus represent crown-group multicellular rhodophytes, antedating the oldest previously accepted red alga in the fossil record by about 400 million years. PMID:28291791

  6. Three-dimensional preservation of cellular and subcellular structures suggests 1.6 billion-year-old crown-group red algae.

    PubMed

    Bengtson, Stefan; Sallstedt, Therese; Belivanova, Veneta; Whitehouse, Martin

    2017-03-01

    The ~1.6 Ga Tirohan Dolomite of the Lower Vindhyan in central India contains phosphatized stromatolitic microbialites. We report from there uniquely well-preserved fossils interpreted as probable crown-group rhodophytes (red algae). The filamentous form Rafatazmia chitrakootensis n. gen, n. sp. has uniserial rows of large cells and grows through diffusely distributed septation. Each cell has a centrally suspended, conspicuous rhomboidal disk interpreted as a pyrenoid. The septa between the cells have central structures that may represent pit connections and pit plugs. Another filamentous form, Denaricion mendax n. gen., n. sp., has coin-like cells reminiscent of those in large sulfur-oxidizing bacteria but much more recalcitrant than the liquid-vacuole-filled cells of the latter. There are also resemblances with oscillatoriacean cyanobacteria, although cell volumes in the latter are much smaller. The wider affinities of Denaricion are uncertain. Ramathallus lobatus n. gen., n. sp. is a lobate sessile alga with pseudoparenchymatous thallus, "cell fountains," and apical growth, suggesting florideophycean affinity. If these inferences are correct, Rafatazmia and Ramathallus represent crown-group multicellular rhodophytes, antedating the oldest previously accepted red alga in the fossil record by about 400 million years.

  7. Insensitive Munitions (Les Munitions a Risque Attenue)

    DTIC Science & Technology

    1992-07-01

    hydrocar- a banana plug connector attached to the bon and silicone oils resulted in such a high ground wire that would be attached during friction load...had a banana diameter upper electrode rod passed through plug connector attached to the high voltage the nylon insulator. It was much longer (350...mm deep so that it hole was put through the center of the could accept a banana plug attached to the propellant contact to enable acceptance of a

  8. [Dampness in an electric plug as a cause of electricity failure in an operation theatre].

    PubMed

    Andersen, C; Pold, R; Nielsen, H D

    2000-02-07

    Two cases of electricity failure in an operation theatre during open heart surgery are discussed. The fuse for the patient monitor, ventilator, surgery instruments and heart lung machine was blown. Short-circuit was established because of humidity in the plug of the heater for fluid and blood. We recommend sealed or founded plugs and that anaesthesia equipment should not be used as an electrical supply for other electronic apparatus.

  9. Experimental cold-flow evaluation of a ram air cooled plug nozzle concept for afterburning turbojet engines

    NASA Technical Reports Server (NTRS)

    Straight, D. M.; Harrington, D. E.

    1973-01-01

    A concept for plug nozzles cooled by inlet ram air is presented. Experimental data obtained with a small scale model, 21.59-cm (8.5-in.) diameter, in a static altitude facility demonstrated high thrust performance and excellent pumping characteristics. Tests were made at nozzle pressure ratios simulating supersonic cruise and takeoff conditions. Effect of plug size, outer shroud length, and varying amounts of secondary flow were investigated.

  10. Performance characteristics of an isolated coannular plug nozzle at transonic speeds

    NASA Technical Reports Server (NTRS)

    Mercer, C. E.; Burley, J. R., II

    1985-01-01

    The Langley 16-Foot Transonic Tunnel was used to evaluate the performance characteristics of a coannular plug nozzle at static conditions (Mach number of 0) and at Mach numbers from 0.65 to 1.20. Jet total pressure ratio was varied from 1.0 (jet off) to 10.0. Thirty-seven configurations generated by the combination of three geometric variables - plug angle, shroud boattail length (fixed exit radius), and shroud extension length - were tested.

  11. Cryogenic support member

    DOEpatents

    Niemann, Ralph C.; Gonczy, John D.; Nicol, Thomas H.

    1987-01-01

    A cryogenic support member is comprised of a non-metallic rod having a depression in at least one end and a metallic end connection assembled to the rod. The metallic end connection comprises a metallic plug which conforms to the shape and is disposed in the depression and a metallic sleeve is disposed over the rod and plug. The plug and the sleeve are shrink-fitted to the depression in the rod to form a connection good in compression, tension and bending.

  12. Airway reopening through catastrophic events in a hierarchical network

    PubMed Central

    Baudoin, Michael; Song, Yu; Manneville, Paul; Baroud, Charles N.

    2013-01-01

    When you reach with your straw for the final drops of a milkshake, the liquid forms a train of plugs that flow slowly initially because of the high viscosity. They then suddenly rupture and are replaced with a rapid airflow with the characteristic slurping sound. Trains of liquid plugs also are observed in complex geometries, such as porous media during petroleum extraction, in microfluidic two-phase flows, or in flows in the pulmonary airway tree under pathological conditions. The dynamics of rupture events in these geometries play the dominant role in the spatial distribution of the flow and in determining how much of the medium remains occluded. Here we show that the flow of a train of plugs in a straight channel is always unstable to breaking through a cascade of ruptures. Collective effects considerably modify the rupture dynamics of plug trains: Interactions among nearest neighbors take place through the wetting films and slow down the cascade, whereas global interactions, through the total resistance to flow of the train, accelerate the dynamics after each plug rupture. In a branching tree of microchannels, similar cascades occur along paths that connect the input to a particular output. This divides the initial tree into several independent subnetworks, which then evolve independently of one another. The spatiotemporal distribution of the cascades is random, owing to strong sensitivity to the plug divisions at the bifurcations. PMID:23277557

  13. Effect of beam channel plugging on the outcome of gamma knife radiosurgery for trigeminal neuralgia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Massager, Nicolas; Nissim, Ouzi; Murata, Noriko

    2006-07-15

    Purpose: We studied the influence of using plugs for brainstem protection during gamma knife radiosurgery (GKR) of trigeminal neuralgia (TN), with special emphasis on irradiation doses delivered to the trigeminal nerve, pain outcomes, and incidence of trigeminal dysfunction. Methods and Materials: A GKR procedure for TN using an anterior cisternal target and a maximum dose of 90 Gy was performed in 109 patients. For 49 patients, customized beam channel blocking (plugs) were used to reduce the dose delivered to the brainstem. We measured the mean and integrated radiation doses delivered to the trigeminal nerve and the clinical course of patientsmore » treated with and without plugs. Results: We found that blocking increases the length of trigeminal nerve exposed to high-dose radiation, resulting in a significantly higher mean dose to the trigeminal nerve. Significantly more of the patients with blocking achieved excellent pain outcomes (84% vs. 62%), but with higher incidences of moderate and bothersome trigeminal nerve dysfunction (37% mild/10% bothersome with plugs vs. 30% mild/2% bothersome without). Conclusions: The use of plugs to protect the brainstem during GKR treatment for TN increases the dose of irradiation delivered to the intracisternal trigeminal nerve root and is associated with an important increase in the incidence of trigeminal nerve dysfunction. Therefore, beam channel blocking should be avoided for 90 Gy-GKR of TN.« less

  14. Determination of total mercury in whole-body fish and fish muscle plugs collected from the South Fork of the Humboldt River, Nevada, September 2005

    USGS Publications Warehouse

    May, Thomas W.; Brumbaugh, William G.

    2007-01-01

    This report presents the results of a study by the U.S. Geological Survey, done in cooperation with the U.S. Bureau of Reclamation, to determine mercury concentrations in whole-body fish and fish muscle plugs from the South Fork of the Humboldt River near Elko in the Te-Moak Indian Reservation. A single muscle plug was collected from beneath the dorsal fin area in each of the three whole-body fish samples. After homogenization and lyophilization of the muscle plugs and whole-body fish samples, mercury concentrations were determined with a direct mercury analyzer utilizing the process of thermal combustion-gold amalgamation atomic absorption spectroscopy. Mercury concentrations in whole-body fish ranged from 0.048 to 0.061 microgram per gram wet weight, and 0.061 to 0.082 microgram per gram wet weight in muscle plugs. All sample mercury concentrations were well below the U.S. Environmental Protection Agency's fish consumption advisory of 0.30 microgram per gram wet weight.

  15. [Bath Plug Closure Method for Cerebrospinal Fluid Leakage by Endoscopic Endonasal Approach:Cooperative Treatment by Neurosurgeons and Otolaryngologists].

    PubMed

    Kawaguchi, Tomohiro; Arakawa, Kazuya; Nomura, Kazuhiro; Ogawa, Yoshikazu; Katori, Yukio; Tominaga, Teiji

    2017-12-01

    Endoscopic endonasal surgery, an innovative surgical technique, is used to approach sinus lesions, lesions of the skull base, and intradural tumors. The cooperation of experienced otolaryngologists and neurosurgeons is important to achieve safe and reliable surgical results. The bath plug closure method is a treatment option for patients with cerebrospinal fluid(CSF)leakage. Although it includes dural and/or intradural procedures, surgery tends to be performed by otolaryngologists because its indications, detailed maneuvers, and pitfalls are not well recognized by neurosurgeons. We reviewed the cases of patients with CSF leakage treated by using the bath plug closure method with an endoscopic endonasal approach at our institution. Three patients were treated using the bath plug closure method. CSF leakage was caused by a meningocele in two cases and trauma in one case. No postoperative intracranial complications or recurrence of CSF leakage were observed. The bath plug closure method is an effective treatment strategy and allows neurosurgeons to gain in-depth knowledge of the treatment options for CSF leakage by using an endoscopic endonasal approach.

  16. Influence of Immobilized Biomolecules on Magnetic Bead Plug Formation and Retention in Capillary Electrophoresis

    PubMed Central

    Henken, Rachel L.; Chantiwas, Rattikan; Gilman, S. Douglass

    2012-01-01

    Significant changes in the formation and retention of magnetic bead plugs in a capillary during electrophoresis were studied, and it was demonstrated that these effects were due to the type of biological molecule immobilized on the surface of these beads. Three biological molecules, an antibody, an oligonucleotide and alkaline phosphatase, were attached to otherwise identical streptavidin-coated magnetic beads through biotin-avidin binding in order to isolate differences in bead immobilization in a magnetic field resulting from the type of biological molecule immobilized on the bead surface. Alkaline phosphatase also was attached to the magnetic beads using epoxy groups on the bead surfaces (instead of avidin-biotin binding) to study the impact of immobilization chemistry. The formation and retention of magnetic bead plugs were studied quantitatively using light scattering detection of magnetic particles eluting from the bead plugs and qualitatively using microscopy. Both the type of biomolecule immobilized on the magnetic bead surface and the chemistry used to link the biomolecule to the magnetic bead impacted the formation and retention of the bead plugs. PMID:22437880

  17. Advantages and Disadvantages of the Amplatzer Vascular Plug IV in Visceral Embolization: Report of 50 Placements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pech, Maciej, E-mail: maciej.pech@med.ovgu.de; Mohnike, Konrad; Wieners, Gero

    2011-10-15

    Purpose: We describe our initial clinical experience in artificial embolization with the Amplatzer Vascular Plug IV (VP IV), a further development of the Vascular Plug family already in routine use. Methods: Results from 50 embolization procedures conducted with the VP IV in 44 patients are summarized. Results: All 50 embolizations were successful, although two required the technique to be modified because of problems with jamming of the screw thread and thus with disconnection of the plug. This was associated with large branching angles. Conclusions: With experience, the VP IV can be used safely and effectively, and it expands the spectrummore » of possible embolizations in interventional radiology. Its greatest disadvantage is its relatively poor positional controllability.« less

  18. Defect specific maintenance of SG tubes -- How safe is it?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cizelj, L.; Mavko, B.; Dvorsek, T.

    1997-02-01

    The efficiency of the defect specific plugging criterion for outside diameter stress corrosion cracking at tube support plates is assessed. The efficiency is defined by three parameters: (1) number of plugged tubes, (2) probability of steam generator tube rupture and (3) predicted accidental leak rate through the defects. A probabilistic model is proposed to quantify the probability of tube rupture, while procedures available in literature were used to define the accidental leak rates. The defect specific plugging criterion was then compared to the performance of traditional (45%) plugging criterion using realistic data from Krsko nuclear power plant. Advantages of themore » defect specific approach over the traditional one are clearly shown. Some hints on the optimization of safe life of steam generator are also given.« less

  19. Acute Delamination of Commercially Available Decellularized Osteochondral Allograft Plugs

    PubMed Central

    Degen, Ryan M.; Tetreault, Danielle; Mahony, Greg T.; Williams, Riley J.

    2016-01-01

    Articular cartilage injuries, and corresponding surgical procedures, are occurring with increasing frequency as identified by a review of recent surgical trends. Concerns have grown in recent years regarding the longevity of results following microfracture, with a shift toward cartilage restoration procedures in recent years. This case report describes 2 cases of acute failure following the use of commercially available osteochondral allograft plugs used for the treatment of osteochondral defects of the distal femur. In both cases the chondral surface of the plug delaminated from the underlying cancellous bone, resulting in persistent pain and swelling requiring reoperation and removal of the loose fragments. Caution should be employed when considering use of these plugs for the treatment of osteochondral lesions, as similar outcomes have not been noted with other cartilage restoration techniques. PMID:27688840

  20. Free jet feasibility study of a thermal acoustic shield concept for AST/VCE application-dual flow. Comprehensive data report. Volume 1: Test nozzles and acoustic data

    NASA Technical Reports Server (NTRS)

    Janardan, B. A.; Brausch, J. F.; Price, A. O.

    1984-01-01

    Acoustic and diagnostic data that were obtained to determine the influence of selected geometric and aerodynamic flow variables of coannular nozzles with thermal acoustic shields are summarized in this comprehensive data report. A total of 136 static and simulated flight acoustic test points were conducted with 9 scale-model nozzles The tested nozzles included baseline (unshielded), 180 deg shielded, and 360 deg shielded dual flow coannular plug configurations. The baseline configurations include a high radius ratio unsuppressed coannular plug nozzle and a coanuular plug nozzle and a coannular plug nozzle with a 20-chute outer stream suppressor. The tests were conducted at nozzle temperatures and pressure typical of operating conditions of variable cycle engine.

  1. Bagless transfer process and apparatus for radioactive waste confinement

    DOEpatents

    Maxwell, D.N.; Hones, R.H.; Rogers, M.L.

    1998-04-14

    A process and apparatus are provided for removing radioactive material from a glovebox, placing the material in a stainless steel storage vessel in communication with the glovebox, and sealing the vessel with a welded plug. The vessel is then severed along the weld, a lower half of the plug forming a closure for the vessel. The remaining welded plug half provides a seal for the remnant portion of the vessel and thereby maintains the sealed integrity of the glovebox. 7 figs.

  2. Bagless transfer process and apparatus for radioactive waste confinement

    DOEpatents

    Maxwell, David N.; Hones, Robert H.; Rogers, M. Lane

    1998-01-01

    A process and apparatus is provided for removing radioactive material from a glovebox, placing the material in a stainless steel storage vessel in communication with the glovebox, and sealing the vessel with a welded plug. The vessel is then severed along the weld, a lower half of the plug forming a closure for the vessel. The remaining welded plug half provides a seal for the remnant portion of the vessel and thereby maintains the sealed integrity of the glovebox.

  3. Amplatzer vascular plug as an embolic agent in different vascular pathologies: A pictorial essay

    PubMed Central

    Tresley, Jonathan; Bhatia, Shivank; Kably, Issam; Poozhikunnath Mohan, Prasoon; Salsamendi, Jason; Narayanan, Govindarajan

    2016-01-01

    The Amplatzer Vascular Plug (AVP) is a cylindrical plug made of self-expanding nitinol wire mesh with precise delivery control, which can be used for a variety of vascular pathologies. An AVP is an ideal vascular occlusion device particularly in high-flow vessels, where there is high risk of migration and systemic embolization with traditional occlusion devices. We performed 28 embolizations using the AVP from 2009 to 2014 and achieved complete occlusion without complications. PMID:27413276

  4. Preliminary Investigation of Methods to Increase Base Pressure of Plug Nozzles at Mach 0.9

    NASA Technical Reports Server (NTRS)

    Salmi, Reino J

    1956-01-01

    The effects of various afterbody changes on the base pressure of a nacelle-type isentropic plug nozzle installation operating at lower-than-design jet pressure ratios were investigated at a Mach number of 0.9. Although the estimates of the net propulsive force contain some uncertainties, the results indicate that both a plain-ring base shroud and a circular-arc boattail fairing reduced the loss in net propulsive force experienced with a cylindrical nacelle installation of the plug nozzle.

  5. Strategies for Controlling Plug Loads. A Tool for Reducing Plug Loads in Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torcellini, Paul; Bonnema, Eric; Sheppy, Michael

    2015-09-01

    Plug loads are often not considered as part of the energy savings measures in Commercial Buildings; however, they can account for up to 50% of the energy used in the building. These loads are numerous and often scattered throughout a building. Some of these loads are purchased by the owner and some designed into the building or the tenant finishes for a space. This document provides a strategy and a tool for minimizing these loads.

  6. Public Key-Based Need-to-Know Authorization Engine Final Report CRADA No. TSB-1553-98

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mark, R.; Williams, R.

    The goals of this project were to develop a public key-based authentication service plug-in based on LLNL's requirements, integrate the public key-based authentication with the Intra Verse authorization service adn the LLNL NTK server by developing a full-featured version of the prototyped Intra Verse need-to-know plug in; and to test the authorization and need-to-know plug-in in a secured extranet prototype among selected national Labs.

  7. Successful transcatheter closure of a congenital high-flow portosystemic venous shunt with the Amplatzer vascular plug II.

    PubMed

    Guneyli, Serkan; Cinar, Celal; Bozkaya, Halil; Parildar, Mustafa; Oran, Ismail; Akin, Yigit

    2012-12-01

    Congenital portosystemic venous shunt is extremely rare and should be treated. Advances in treatment techniques allow for patients to be treated safely. We present a 9-year-old boy with a large congenital portosystemic venous shunt. The shunt was occluded interventionally with the Amplatzer vascular plug II. Our case was unique with its clinical manifestation, the use of a 22-mm Amplatzer vascular plug II, and the presence of the patient's 1-year follow-up.

  8. Plug-in electric vehicles: future market conditions and adoption rates

    EIA Publications

    2017-01-01

    This report, the first of four Issues in Focus articles from the International Energy Outlook 2017, analyzes the effects of uncertainties in the adoption of plug-in electric vehicles (PEVs) on worldwide transportation energy consumption. Uncertainties surrounding consumer acceptance, vehicle cost, policies, and other market conditions could affect future adoption rates of plug-in electric vehicles. Two side cases are presented in this report that assume different levels of PEV adoption and result in different levels of worldwide transportation energy consumption.

  9. [APPLICATION OF FISTULA PLUG WITH THE FIBRIN ADHESIVE IN TREATMENT OF RECTAL FISTULAS].

    PubMed

    Aydinova, P R; Aliyev, E A

    2015-05-01

    Results of surgical treatment of 21 patients, suffering high transsphincteric and extrasphincteric rectal fistulas, were studied. In patients of Group I the fistula passage was closed, using fistula plug obturator; and in patients of Group II--by the same, but preprocessed by fibrin adhesive. The fistula aperture germeticity, prophylaxis of rude cicatrices development in operative wound zone, promotion of better fixation of bioplastic material were guaranteed, using fistula plug obturator with preprocessing, using fibrin adhesive.

  10. Quasi-Porous Plug With Vortex Chamber

    NASA Technical Reports Server (NTRS)

    Walsh, J. V.

    1985-01-01

    Pressure-letdown valve combines quasi-porous-plug and vortex-chamber in one controllable unit. Valve useful in fossil-energy plants for reducing pressures in such erosive two-phase process streams as steam/water, coal slurries, or combustion gases with entrained particles. Quasi-Porous Plug consists of plenums separated by perforated plates. Number or size of perforations increases with each succeeding stage to compensate for expansion. In Vortex Chamber, control flow varies to control swirl and therefore difference between inlet and outlet pressures.

  11. Spatial dynamics of overbank sedimentation in floodplain systems

    USGS Publications Warehouse

    Pierce, Aaron R.; King, S.L.

    2008-01-01

    Floodplains provide valuable social and ecological functions, and understanding the rates and patterns of overbank sedimentation is critical for river basin management and rehabilitation. Channelization of alluvial systems throughout the world has altered hydrological and sedimentation processes within floodplain ecosystems. In the loess belt region of the Lower Mississippi Alluvial Valley of the United States, channelization, the geology of the region, and past land-use practices have resulted in the formation of dozens of valley plugs in stream channels and the formation of shoals at the confluence of stream systems. Valley plugs completely block stream channels with sediment and debris and can result in greater deposition rates on floodplain surfaces. Presently, however, information is lacking on the rates and variability of overbank sedimentation associated with valley plugs and shoals. We quantified deposition rates and textures in floodplains along channelized streams that contained valley plugs and shoals, in addition to floodplains occurring along an unchannelized stream, to improve our understanding of overbank sedimentation associated with channelized streams. Feldspar clay marker horizons and marker poles were used to measure floodplain deposition from 2002 to 2005 and data were analyzed with geospatial statistics to determine the spatial dynamics of sedimentation within the floodplains. Mean sediment deposition rates ranged from 0.09 to 0.67??cm/y at unchannelized sites, 0.16 to 2.27??cm/y at shoal sites, and 3.44 to 6.20??cm/y at valley plug sites. Valley plug sites had greater rates of deposition, and the deposited sediments contained more coarse sand material than either shoal or unchannelized sites. A total of 59 of 183 valley plug study plots had mean deposition rates > 5??cm/y. The geospatial analyses showed that the spatial dynamics of sedimentation can be influenced by the formation of valley plugs and shoals on channelized streams; however, responses can vary. Restoration efforts in the region need to have basinwide collaboration with landowners and address catchment-scale processes, including the geomorphic instability of the region, to be successful. ?? 2008 Elsevier B.V. All rights reserved.

  12. Towards a Multifunctional Electrochemical Sensing and Niosome Generation Lab-on-Chip Platform Based on a Plug-and-Play Concept.

    PubMed

    Kara, Adnane; Rouillard, Camille; Mathault, Jessy; Boisvert, Martin; Tessier, Frédéric; Landari, Hamza; Melki, Imene; Laprise-Pelletier, Myriam; Boisselier, Elodie; Fortin, Marc-André; Boilard, Eric; Greener, Jesse; Miled, Amine

    2016-05-28

    In this paper, we present a new modular lab on a chip design for multimodal neurotransmitter (NT) sensing and niosome generation based on a plug-and-play concept. This architecture is a first step toward an automated platform for an automated modulation of neurotransmitter concentration to understand and/or treat neurodegenerative diseases. A modular approach has been adopted in order to handle measurement or drug delivery or both measurement and drug delivery simultaneously. The system is composed of three fully independent modules: three-channel peristaltic micropumping system, a three-channel potentiostat and a multi-unit microfluidic system composed of pseudo-Y and cross-shape channels containing a miniature electrode array. The system was wirelessly controlled by a computer interface. The system is compact, with all the microfluidic and sensing components packaged in a 5 cm × 4 cm × 4 cm box. Applied to serotonin, a linear calibration curve down to 0.125 mM, with a limit of detection of 31 μ M was collected at unfunctionalized electrodes. Added sensitivity and selectivity was achieved by incorporating functionalized electrodes for dopamine sensing. Electrode functionalization was achieved with gold nanoparticles and using DNA and o-phenylene diamine polymer. The as-configured platform is demonstrated as a central component toward an "intelligent" drug delivery system based on a feedback loop to monitor drug delivery.

  13. Towards a Multifunctional Electrochemical Sensing and Niosome Generation Lab-on-Chip Platform Based on a Plug-and-Play Concept

    PubMed Central

    Kara, Adnane; Rouillard, Camille; Mathault, Jessy; Boisvert, Martin; Tessier, Frédéric; Landari, Hamza; Melki, Imene; Laprise-Pelletier, Myriam; Boisselier, Elodie; Fortin, Marc-André; Boilard, Eric; Greener, Jesse; Miled, Amine

    2016-01-01

    In this paper, we present a new modular lab on a chip design for multimodal neurotransmitter (NT) sensing and niosome generation based on a plug-and-play concept. This architecture is a first step toward an automated platform for an automated modulation of neurotransmitter concentration to understand and/or treat neurodegenerative diseases. A modular approach has been adopted in order to handle measurement or drug delivery or both measurement and drug delivery simultaneously. The system is composed of three fully independent modules: three-channel peristaltic micropumping system, a three-channel potentiostat and a multi-unit microfluidic system composed of pseudo-Y and cross-shape channels containing a miniature electrode array. The system was wirelessly controlled by a computer interface. The system is compact, with all the microfluidic and sensing components packaged in a 5 cm × 4 cm × 4 cm box. Applied to serotonin, a linear calibration curve down to 0.125 mM, with a limit of detection of 31 μM was collected at unfunctionalized electrodes. Added sensitivity and selectivity was achieved by incorporating functionalized electrodes for dopamine sensing. Electrode functionalization was achieved with gold nanoparticles and using DNA and o-phenylene diamine polymer. The as-configured platform is demonstrated as a central component toward an “intelligent” drug delivery system based on a feedback loop to monitor drug delivery. PMID:27240377

  14. Petrography and petrology of Smoky Butte intrusives, Garfield County, Montana

    USGS Publications Warehouse

    Matson, Robert E.

    1960-01-01

    The Smoky Butte intrusives are located in T. 18 N., R. 36 E. Garfield County, Montana on the extreme eastern edge of the petrographic province of Central Montana. They consist of dikes and plugs arranged in linear, en-echelon pattern with a northeast trend and intrude the Tullock member (Paleocene age) of the Fort Union formation. Extrusive rocks are absent. The rocks are potassium-rich volcanic types showing a disequilibrium mineral assemblage consisting of sanidine, leucite, biotite, olivine, pyroxene, magnetite plus. ilmenite, apatite, calcite, quartz, and a yellowish to dark greenish glassy groundmass. Two chemical analyses of Smoky Butte rocks show high magnesium, potassium, titanium, and phosphorous and low aluminum and sodium content. The two norm calculations show that the rocks are oversaturated with 1.3 and 3.1 per-cent excess silica. Because of the peculiar nature of the Smoky Butte rocks, descriptive names have been applied to them. They are divided into six different types. Three periods of intrusion are proposed for Smoky Butte quarry where three rock types crop out. Other evidence for multiple injection occurs in several multiple dikes. The upper contact of the intrusion is visible on a few plugs and dikes. Smoky Butte rocks show some similarities to the undersaturated potassium-rich rocks of the Highwood and Bearpaw Mountains of Montana, the rocks of the Leucite Hills of Wyoming, and the oversaturated rocks of the West Kimberly District of Australia.

  15. A context management system for a cost-efficient smart home platform

    NASA Astrophysics Data System (ADS)

    Schneider, J.; Klein, A.; Mannweiler, C.; Schotten, H. D.

    2012-09-01

    This paper presents an overview of state-of-the-art architectures for integrating wireless sensor and actuators networks into the Future Internet. Furthermore, we will address advantages and disadvantages of the different architectures. With respect to these criteria, we develop a new architecture overcoming these weaknesses. Our system, called Smart Home Context Management System, will be used for intelligent home utilities, appliances, and electronics and includes physical, logical as well as network context sources within one concept. It considers important aspects and requirements of modern context management systems for smart X applications: plug and play as well as plug and trust capabilities, scalability, extensibility, security, and adaptability. As such, it is able to control roller blinds, heating systems as well as learn, for example, the user's taste w.r.t. to home entertainment (music, videos, etc.). Moreover, Smart Grid applications and Ambient Assisted Living (AAL) functions are applicable. With respect to AAL, we included an Emergency Handling function. It assures that emergency calls (police, ambulance or fire department) are processed appropriately. Our concept is based on a centralized Context Broker architecture, enhanced by a distributed Context Broker system. The goal of this concept is to develop a simple, low-priced, multi-functional, and save architecture affordable for everybody. Individual components of the architecture are well tested. Implementation and testing of the architecture as a whole is in progress.

  16. Route of steroid-activated macromolecules through nuclear pores imaged with atomic force microscopy.

    PubMed

    Oberleithner, H; Schäfer, C; Shahin, V; Albermann, L

    2003-02-01

    In eukaryotic cells, two concentric membranes, the nuclear envelope (NE), separate the nucleus from the cytoplasm. The NE is punctured by nuclear pore complexes (NPCs; molecular mass 120 MDa) that serve as regulated pathways for macromolecules entering and leaving the nuclear compartment. Transport across NPCs occurs through central channels. Such import and export of macromolecules through individual NPCs can be elicited in the Xenopus laevis oocyte by injecting the mineralocorticoid aldosterone and can be visualized with atomic force microscopy. The electrical NE resistance in intact cell nuclei can be measured in parallel. Resistance increases when macromolecules are engaged with the NPC. This article describe six observations made from these experiments and the conclusions that can be drawn from them. (i) A homogeneous population of macromolecules (approx. 100 kDa) attaches to the cytoplasmic face of the NPC 2 min after aldosterone injection. They are most likely to be aldosterone receptors. After a few minutes, they have disappeared. (ii) Large plugs (approx. molecular mass 1 MDa) appear in the central channels 20 min after hormone injection. They are most likely to be ribonucleoproteins exiting the nucleus. (iii) Electrical resistance measurements in isolated nuclei reveal transient electrical NE resistance peaks: an early (2 min) peak and a late (20 min) peak. Electrical peaks reflect macromolecule interaction with the NPC. (iv) Spironolactone blocks both the early and late peaks. This indicates that classic aldosterone receptors are involved in the pregenomic (early) and post-genomic (late) responses. (v) Actinomycin D and, independently, RNase A block the late electrical peak, confirming that plugs are genomic in nature. (vi) Intracellular calcium chelation blocks both early and late electrical peaks. Thus, the release of calcium from internal stores, which is known to be the first intracellular signal in response to aldosterone, is a prerequisite for the late genomic response.

  17. Methodology for Mechanical Property Testing on Fuel Cladding Using an Expanded Plug Wedge Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jy-An John; Jiang, Hao

    To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at ORNL and is described fully in US Patent Application 20060070455, Expanded plug method for developing circumferential mechanical properties of tubular materials. This method is designed for testing fuel rod cladding ductility in a hot cell utilizing an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are the simplicity of measuring the testmore » component assembly in the hot cell and the direct measurement of specimen strain. It was also found that cladding strength could be determined from the test results. The basic approach of this test method is to apply an axial compressive load to a cylindrical plug of polyurethane (or other materials) fitted inside a short ring of the test material to achieve radial expansion of the specimen. The diameter increase of the specimen is used to calculate the circumferential strain accrued during the test. The other two basic measurements are total applied load and amount of plug compression (extension). A simple procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves. However, several deficiencies exist in this expanded-plug loading ring test, which will impact accuracy of test results and introduce potential shear failure of the specimen due to inherited large axial compressive stress from the expansion plug test. First of all, the highly non-uniform stress and strain distribution resulted in the gage section of the clad. To ensure reliable testing and test repeatability, the potential for highly non-uniform stress distribution or displacement/strain deformation has to be eliminated at the gage section of the specimen. Second, significant compressive stresses were induced by clad bending deformation due to a clad bulging effect (or the barreling effect). The barreling effect caused very large localized shear stress in the clad and left testing material at a high risk of shear failure. The above combined effects will result in highly non-conservative predictions both in strength and ductility of the tested clad, and the associated mechanical properties as well. To overcome/mitigate the mentioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. Through detailed parameter investigation on specific geometry designs, careful filtering of material for the expansion plug, as well as adding newly designed parts to the testing system, a method to reconcile the potential non-conservatism embedded in the expansion plug test system has been discovered. A modified expansion plug testing protocol has been developed based on the method. In order to closely resemble thin-wall theory, a general procedure was also developed to determine the hoop stress in the tested ring specimen. A scaling factor called -factor is defined to correlate the ring load P into hoop stress . , = . The generated stress-strain curve agrees very well with tensile test data in both the elastic and plastic regions.« less

  18. 40 CFR 147.3011 - Plugging and abandonment of Class III wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Lands of the Navajo, Ute Mountain Ute, and All Other New Mexico Tribes § 147.3011 Plugging and...

  19. Management of Gastropleural Fistula after Revisional Bariatric Surgery: A Hybrid Laparoendoscopic Approach.

    PubMed

    Ghanem, Omar M; Abu Dayyeh, Barham K; Kellogg, Todd A

    2017-10-01

    Gastropleural fistula (GPF) is a serious complication after bariatric surgery. Multiple treatment modalities including pharmacologic, endoscopic, and revisional surgery have been proposed. We present a case of a GPF managed successfully with a laparoendoscopic approach utilizing a fistula plug. A 43-year-old male patient presented with a GPF after a revisional bariatric surgery. A laparoendoscopic approach including lysis of adhesions, identification of the fistula, plugging the fistula with a BioGore A® fistula plug, placement an enteric stent, placement of a feeding tube, and surgical drainage was performed. The multimedia video illustrates the technique used. Postoperatively, upper gastrointestinal (UGI) imaging showed no evidence of leak. The enteric stent was removed after 2 months after verifying complete healing of the fistula. A laparoendoscopic approach to GPF repair with the use of fistula plug is effective, safe, and feasible.

  20. Revascularization and Apical Plug in an Immature Molar

    PubMed Central

    Roghanizadeh, Leyla; Fazlyab, Mahta

    2018-01-01

    Managing of necrotic permanent teeth with immature apices is a treatment challenges. Treatment of such teeth includes apexification, apical plug and more recently, revascularization technique with the probable advantage of continuation of root development. In the present case report the referred patient had discomfort with a necrotic immature mandibular first molar. Periapical radiography showed a rather large apical lesion around immature roots. Revascularization protocol using calcium-enriched mixture (CEM) cement was indicated for the mesial root. However, in distal canal apical plug technique was applied. At 2-year follow-up, both procedures were successful in relieving patient’s symptoms. Dentin formation and increase in length of the mesial root was obvious. Apical plug and revascularization technique proved to be successful in management of necrotic immature teeth; moreover, revascularization carried the advantage of continuation of root development. PMID:29692851

  1. Superfluid helium 2 liquid-vapor phase separation: Technology assessment

    NASA Technical Reports Server (NTRS)

    Lee, J. M.

    1984-01-01

    A literature survey of helium 2 liquid vapor phase separation is presented. Currently, two types of He 2 phase separators are being investigated: porous, sintered metal plugs and the active phase separator. The permeability K(P) shows consistency in porous plug geometric characterization. Both the heat and mass fluxes increase with K(P). Downstream pressure regulation to adjust for varying heat loads and both temperatures is possible. For large dynamic heat loads, the active phase separator shows a maximum heat rejection rate of up to 2 W and bath temperature stability of 0.1 mK. Porous plug phase separation performance should be investigated for application to SIRTF and, in particular, that plugs of from 10 to the minus ninth square centimeters to 10 to the minus eighth square centimeters in conjunction with downstream pressure regulation be studied.

  2. Experimental investigation of gas hydrate formation, plugging and transportability in partially dispersed and water continuous systems

    NASA Astrophysics Data System (ADS)

    Vijayamohan, Prithvi

    As oil/gas subsea fields mature, the amount of water produced increases significantly due to the production methods employed to enhance the recovery of oil. This is true especially in the case of oil reservoirs. This increase in the water hold up increases the risk of hydrate plug formation in the pipelines, thereby resulting in higher inhibition cost strategies. A major industry concern is to reduce the severe safety risks associated with hydrate plug formation, and significantly extending subsea tieback distances by providing a cost effective flow assurance management/safety tool for mature fields. Developing fundamental understanding of the key mechanistic steps towards hydrate plug formation for different multiphase flow conditions is a key challenge to the flow assurance community. Such understanding can ultimately provide new insight and hydrate management guidelines to diminish the safety risks due to hydrate formation and accumulation in deepwater flowlines and facilities. The transportability of hydrates in pipelines is a function of the operating parameters, such as temperature, pressure, fluid mixture velocity, liquid loading, and fluid system characteristics. Specifically, the hydrate formation rate and plugging onset characteristics can be significantly different for water continuous, oil continuous, and partially dispersed systems. The latter is defined as a system containing oil/gas/water, where the water is present both as a free phase and partially dispersed in the oil phase (i.e., entrained water in the oil). Since hydrate formation from oil dispersed in water systems and partially dispersed water systems is an area which is poorly understood, this thesis aims to address some key questions in these systems. Selected experiments have been performed at the University of Tulsa flowloop to study the hydrate formation and plugging characteristics for the partially dispersed water/oil/gas systems as well as systems where the oil is completely dispersed in water. These experiments indicate that the partially dispersed systems tend to be problematic and are more severe cases with respect to flow assurance when compared to systems where the water is completely dispersed in oil. We have found that the partially dispersed systems are distinct, and are not an intermediate case between water dominated, and water-in-oil emulsified systems. Instead the experiments indicate that the hydrate formation and plugging mechanism for these systems are very complex. Hydrate growth is very rapid for such systems when compared to 100% water cut systems. The plugging mechanism for these systems is a combination of various phenomena (wall growth, agglomeration, bedding/settling, etc). Three different oils with different viscosities have been used to investigate the transportability of hydrates with respect to oil properties. The experiments indicate that the transportability of hydrates increases with increase in oil viscosity. The data from the tests performed provide the basis for a mechanistic model for hydrate formation and plugging in partially dispersed systems. It is found that in systems that were in stratified flow regime before hydrate onset, the hydrates eventually settled on the pipe walls thereby decreasing the flow area for the flow of fluids. In systems that were in the slug flow regime before hydrate formation, moving beds of hydrates were the main cause for plugging. In both the flow regimes, the systems studied entered a plugging regime beyond a certain hydrate concentration. This is termed as φplugging onset and can be used as an indicator to calculate the amount of hydrates that can be transported safely without requiring any additional treatment for a given set of flow characteristics. A correlation to calculate this hydrate concentration based on easily accessible parameters is developed in terms of flow characteristics and oil properties. The work performed in this thesis has enhanced the understanding of the hydrate plug mechanism in pipelines having high amounts of water. This work has also shown the effect of hydrate formation in different flow regimes thereby shedding light on the effects of hydrates on multiphase flow and vice versa. Lessons resulting from this work could be incorporated into flow assurance models, as well as operating company production strategies to reduce or mitigate hydrate plugging risks in complex multiphase systems.

  3. Salt Plug Formation Caused by Decreased River Discharge in a Multi-channel Estuary

    PubMed Central

    Shaha, Dinesh Chandra; Cho, Yang-Ki

    2016-01-01

    Freshwater input to estuaries may be greatly altered by the river barrages required to meet human needs for drinking water and irrigation and prevent salt water intrusion. Prior studies have examined the salt plugs associated with evaporation and salt outwelling from tidal salt flats in single-channel estuaries. In this work, we discovered a new type of salt plug formation in the multi-channel Pasur River Estuary (PRE) caused by decreasing river discharges resulting from an upstream barrage. The formation of a salt plug in response to changes in river discharge was investigated using a conductivity-temperature-depth (CTD) recorder during spring and neap tides in the dry and wet seasons in 2014. An exportation of saline water from the Shibsa River Estuary (SRE) to the PRE through the Chunkhuri Channel occurred during the dry season, and a salt plug was created and persisted from December to June near Chalna in the PRE. A discharge-induced, relatively high water level in the PRE during the wet season exerted hydrostatic pressure towards the SRE from the PRE and thereby prevented the intrusion of salt water from the SRE to the PRE. PMID:27255892

  4. Progress on ITER Diagnostic Integration

    NASA Astrophysics Data System (ADS)

    Johnson, David; Feder, Russ; Klabacha, Jonathan; Loesser, Doug; Messineo, Mike; Stratton, Brentley; Wood, Rick; Zhai, Yuhu; Andrew, Phillip; Barnsley, Robin; Bertschinger, Guenter; Debock, Maarten; Reichle, Roger; Udintsev, Victor; Vayakis, George; Watts, Christopher; Walsh, Michael

    2013-10-01

    On ITER, front-end components must operate reliably in a hostile environment. Many will be housed in massive port plugs, which also shield the machine from radiation. Multiple diagnostics reside in a single plug, presenting new challenges for developers. Front-end components must tolerate thermally-induced stresses, disruption-induced mechanical loads, stray ECH radiation, displacement damage, and degradation due to plasma-induced coatings. The impact of failures is amplified due to the difficulty in performing robotic maintenance on these large structures. Motivated by needs to minimize disruption loads on the plugs, standardize the handling of shield modules, and decouple the parallel efforts of the many parties, the packaging strategy for diagnostics has recently focused on the use of 3 vertical shield modules inserted from the plasma side into each equatorial plug structure. At the front of each is a detachable first wall element with customized apertures. Progress on US equatorial and upper plugs will be used as examples, including the layout of components in the interspace and port cell regions. Supported by PPPL under contract DE-AC02-09CH11466 and UT-Battelle, LLC under contract DE-AC05-00OR22725 with the U.S. DOE.

  5. 33 CFR 154.106 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 20, Switzerland. (1) IEC 60309-1 Plugs, Socket-Outlets and Couplers for Industrial Purposes—Part 1: General Requirements, Edition 4.2 2012-06, IBR approved for § 154.2102(b). (2) IEC 60309-2 Plugs, Socket...

  6. 40 CFR 211.210-2 - Labeling requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... constant); (ii) Ear cup volume or shape; (iii) Mounting of ear cup on head band; (iv) Ear cushion; (v... tension (spring constant); (ii) Mounting of plug on head band; (iii) Shape of plug; (iv) Material...

  7. Apparatus tube configuration and mounting for solid oxide fuel cells

    DOEpatents

    Zymboly, G.E.

    1993-09-14

    A generator apparatus is made containing long, hollow, tubular, fuel cells containing an inner air electrode, an outer fuel electrode, and solid electrolyte there between, placed between a fuel distribution board and a board which separates the combustion chamber from the generating chamber, where each fuel cell has an insertable open end and in insertable, plugged, closed end, the plugged end being inserted into the fuel distribution board and the open end being inserted through the separator board where the plug is completely within the fuel distribution board. 3 figures.

  8. Optimal control of a repowered vehicle: Plug-in fuel cell against plug-in hybrid electric powertrain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tribioli, L., E-mail: laura.tribioli@unicusano.it; Cozzolino, R.; Barbieri, M.

    2015-03-10

    This paper describes two different powertrain configurations for the repowering of a conventional vehicle, equipped with an internal combustion engine (ICE). A model of a mid-sized ICE-vehicle is realized and then modified to model both a parallel plug-in hybrid electric powertrain and a proton electrolyte membrane (PEM) fuel cell (FC) hybrid powertrain. The vehicle behavior under the application of an optimal control algorithm for the energy management is analyzed for the different scenarios and results are compared.

  9. Guide to Federal Funding, Financing, and Technical Assistance for Plug-in Electric Vehicles and Charging Stations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    The U.S. Department of Energy and the U.S. Department of Transportation have published a guide to highlight examples of federal support and technical assistance for plug-in electric vehicles (PEVs) and charging stations. The guide provides a description of each opportunity and a point of contact to assist those interested in advancing PEV technology. The Department of Energy’s Alternative Fuels Data Center provides a comprehensive database of federal and state programs that support plug-in electric vehicles and infrastructure.

  10. The Elimination of Fire Hazard Due to Back Fires

    NASA Technical Reports Server (NTRS)

    Theodorsen, Theodore; Freeman, Ira M

    1933-01-01

    A critical study was made of the operation of a type of back-fire arrester used to reduce the fire hazard of aircraft engines. A flame arrester consisting of a pack or plug of alternate flat and corrugated plates of thin metal was installed in the intake pipe of a gasoline engines; an auxiliary spark plug inserted in the intake manifold permitted the production of artificial back fires at will. It was found possible to design a plug which prevented all back fires from reaching the carburetor.

  11. AVTA Federal Fleet PEV Readiness Data Logging and Characterization Study for NASA White Sands Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schey, Stephen; Francfort, Jim

    This report focuses on the NASA White Sands Test Facility (WSTF) fleet to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of plug-in electric vehicles (PEVs) into the agencies’ fleets. Individual observations of these selected vehicles provide the basis for recommendations related to electric vehicle adoption and whether a battery electric vehicle (BEV) or plug-in hybrid electric vehicle (PHEV) (collectively plug-in electric vehicles, or PEVs) can fulfill the mission requirements.

  12. AVTA Federal Fleet PEV Readiness Data Logging and Characterization Study for National Institute of Health

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schey, Stephen; Francfort, Jim

    2014-11-01

    This report focuses on the National Institute of Health (NIH) fleet to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of plug-in electric vehicles (PEVs) into the agencies’ fleets. Individual observations of these selected vehicles provide the basis for recommendations related to electric vehicle adoption and whether a battery electric vehicle (BEV) or plug-in hybrid electric vehicle (PHEV) (collectively plug-in electric vehicles, or PEVs) can fulfill the mission requirements.

  13. Long-term follow-up for ossification of autologous bone plug and skin sinking after periosteum-preserved burr hole surgery.

    PubMed

    Kubota, Hisashi; Sanada, Yasuhiro; Murakami, Saori; Miyauchi, Masaharu; Iwakura, Michihiro; Nagatsuka, Kazuhiro; Furukawa, Kentaro; Kato, Amami; Fujita, Mitsugu

    2017-01-01

    The demand of a burr hole surgery for chronic subdural hematoma (CSDH) is increasing in the global aging society. Burr hole-derived autologous bone dusts are not associated with extra costs compared with other commonly used synthetic materials. In addition, postoperative calvarium ossification requires periosteum-mediated blood supply, which is lacking after using avascular synthetic materials. Based on these findings, we hypothesized that the combination of the bone plugs and the preserved periosteum during burr hole surgeries for CSDH would induce efficient calvarium ossification. We evaluated the long-term effects of bone plugs on the degree of ossification and cosmetic appearance of the skin covering the burr hole sites. We included 8 patients (9 burr holes) who received the autologous bone dust derived from burr holes. As the control group, 9 burr holes that did not receive any burr hole plugs were retrospectively selected. These burr holes were evaluated by computed tomography (CT) scan for the calvarium defect ratios, CT value-based ossification, and the degree of skin sinking. Ossification was observed in all the bone plugs by the bone density CT scans; they maintained their volume at 12 months after the surgeries. The calvarium defect ratios (volume ratios of the unossified parts in the burr holes) gradually increased during the first 6 months and reached 0.44 at 12 months. The mean CT values also increased from 527 HU to 750 HU for the first 6 months and reached 905 HU at 12 months. The degrees of skin sinking at the burr hole sites with the bone plugs were 1.24 mm whereas those without the bone plugs were 2.69 mm ( P = 0.004). Application of burr hole-derived autologous bone dust is associated with better ossification and objective cosmetic result following burr hole surgery after CSDH.

  14. Maximizing the Benefits of Plug-in Electric Vehicles - Continuum Magazine

    Science.gov Websites

    Testing and Integration Facility. Photo by Dennis Schroeder, NREL Maximizing the Benefits of Plug-in . Electric vehicle charging stations in NREL's parking garage. Photo by Dennis Schroder, NREL An NREL

  15. 16 CFR 307.6 - Requirements for disclosure on the label.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., plug of chewing tobacco, or dispenser of individual packages of smokeless tobacco that may be purchased... plug of chewing tobacco—Eight point type, provided that if the warning statement is printed in one line...

  16. Description of a novel mating plug mechanism in spiders and the description of the new species Maeota setastrobilaris (Araneae, Salticidae)

    PubMed Central

    Garcilazo-Cruz, Uriel; Alvarez-Padilla, Fernando

    2015-01-01

    Abstract Reproduction in arthropods is an interesting area of research where intrasexual and intersexual mechanisms have evolved structures with several functions. The mating plugs usually produced by males are good examples of these structures where the main function is to obstruct the female genitalia against new sperm depositions. In spiders several types of mating plugs have been documented, the most common ones include solidified secretions, parts of the bulb or in some extraordinary cases the mutilation of the entire palpal bulb. Here, we describe the first case of modified setae, which are located on the cymbial dorsal base, used directly as a mating plug for the Order Araneae in the species Maeota setastrobilaris sp. n. In addition the taxonomic description of Maeota setastrobilaris sp. n. is provided and based on our findings the geographic distribution of this genus is extended to the Northern hemisphere. PMID:26175601

  17. Interferometric fiber-optic sensor embedded in a spark plug for in-cylinder pressure measurement in engines.

    PubMed

    Bae, Taehan; Atkins, Robert A; Taylor, Henry F; Gibler, William N

    2003-02-20

    Pressure sensing in an internal combustion engine with an intrinsic fiber Fabry-Perot interferometer (FFPI) integrated with a spark plug is demonstrated for the first time. The spark plug was used for the ignition of the cylinder in which it was mounted. The FFPI element, protected with a copper/gold coating, was embedded in a groove in the spark-plug housing. Gas pressure inthe engine induced longitudinal strain in this housing, which was also experienced by the fiber-optic sensing element. The sensor was monitored with a signal conditioning unit containing a chirped distributed-feedback laser. Pressure sensitivities as high as 0.00339 radians round-trip phase shift per pounds per square inch of pressure were observed. Measured pressure versus time traces showed good agreement with those from a piezoelectric reference sensor mounted in the same engine cylinder.

  18. Susceptibility-matched plugs for microcoil NMR probes

    NASA Astrophysics Data System (ADS)

    Kc, Ravi; Gowda, Yashas N.; Djukovic, Danijel; Henry, Ian D.; Park, Gregory H. J.; Raftery, Daniel

    2010-07-01

    For mass-limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5-2 μL) and larger volume (15-20 μL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6-12-fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples.

  19. Susceptibility-matched plugs for microcoil NMR probes.

    PubMed

    Kc, Ravi; Gowda, Yashas N; Djukovic, Danijel; Henry, Ian D; Park, Gregory H J; Raftery, Daniel

    2010-07-01

    For mass-limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5-2 microL) and larger volume (15-20 microL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6-12-fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  20. Interferometric Fiber-Optic Sensor Embedded in a Spark Plug for In-Cylinder Pressure Measurement in Engines

    NASA Astrophysics Data System (ADS)

    Bae, Taehan; Atkins, Robert A.; Taylor, Henry F.; Gibler, William N.

    2003-02-01

    Pressure sensing in an internal combustion engine with an intrinsic fiber Fabry-Perot interferometer (FFPI) integrated with a spark plug is demonstrated for the first time. The spark plug was used for the ignition of the cylinder in which it was mounted. The FFPI element, protected with a copper /gold coating, was embedded in a groove in the spark-plug housing. Gas pressure in the engine induced longitudinal strain in this housing, which was also experienced by the fiber-optic sensing element. The sensor was monitored with a signal conditioning unit containing a chirped distributed-feedback laser. Pressure sensitivities as high as 0.00339 radians round-trip phase shift per pounds per square inch of pressure were observed. Measured pressure versus time traces showed good agreement with those from a piezoelectric reference sensor mounted in the same engine cylinder.

  1. Tamper indicating seal

    DOEpatents

    Romero, Juan A [Albuquerque, NM; Walker, Charles A [Albuquerque, NM; Blair, Dianna S [Albuquerque, NM; Bodmer, Connie C [Albuquerque, NM

    2012-05-29

    Seals have a flexible wire that can be looped through a hasp-like device. The seals include a body having a recess, a plug insertable into the recess and a snap ring for fastening the plug to the body. The plug and/or body can have access holes for inserting the wire into the recess. "Teeth" on the outer diameter and through-holes through the thickness of the snap ring allow for passing the ends of the flexible wire from the recess through the snap ring. The ends of the wire can be folded back over the snap ring and into engagement with the teeth. Assembly of the seal causes the ends of the wire to be securely fastened between the teeth of the snap ring and the sidewall of the recess. Seals can include a plug and/or body made of a frangible material such as glass, ceramic, glass-ceramic or brittle polymer.

  2. Susceptibility-matched plugs for microcoil NMR probes

    PubMed Central

    Kc, Ravi; Gowda, Yashas N.; Djukovic, Danijel; Henry, Ian D; Park, Gregory H J; Raftery, Daniel

    2010-01-01

    For mass limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5 to 2 μL) and larger volume (15 to 20 μL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6 to 12 fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples. PMID:20510638

  3. Thermal Pyrolytic Graphite Enhanced Components

    NASA Technical Reports Server (NTRS)

    Hardesty, Robert E. (Inventor)

    2015-01-01

    A thermally conductive composite material, a thermal transfer device made of the material, and a method for making the material are disclosed. Apertures or depressions are formed in aluminum or aluminum alloy. Plugs are formed of thermal pyrolytic graphite. An amount of silicon sufficient for liquid interface diffusion bonding is applied, for example by vapor deposition or use of aluminum silicon alloy foil. The plugs are inserted in the apertures or depressions. Bonding energy is applied, for example by applying pressure and heat using a hot isostatic press. The thermal pyrolytic graphite, aluminum or aluminum alloy and silicon form a eutectic alloy. As a result, the plugs are bonded into the apertures or depressions. The composite material can be machined to produce finished devices such as the thermal transfer device. Thermally conductive planes of the thermal pyrolytic graphite plugs may be aligned in parallel to present a thermal conduction path.

  4. Analytical and experimental study of axisymmetric truncated plug nozzle flow fields

    NASA Technical Reports Server (NTRS)

    Muller, T. J.; Sule, W. P.; Fanning, A. E.; Giel, T. V.; Galanga, F. L.

    1972-01-01

    Experimental and analytical investigation of the flow field and base pressure of internal-external-expansion truncated plug nozzles are discussed. Experimental results for two axisymmetric, conical plug-cylindrical shroud, truncated plug nozzles are presented for both open and closed wake operations. These results include extensive optical and pressure data covering nozzle flow field and base pressure characteristics, diffuser effects, lip shock strength, Mach disc behaviour, and the recompression and reverse flow regions. Transonic experiments for a special planar transonic section are presented. An extension of the analytical method of Hall and Mueller to include the internal shock wave from the shroud exit is presented for closed wake operation. Results of this analysis include effects on the flow field and base pressure of ambient pressure ratio, nozzle geometry, and the ratio of specific heats. Static thrust is presented as a function of ambient pressure ratio and nozzle geometry. A new transonic solution method is also presented.

  5. Flexible Plug Repair for Shuttle Wing Leading Edge

    NASA Technical Reports Server (NTRS)

    Camarda, Charles J.; Sikora, Joseph; Smith, Russel; Rivers, H.; Scotti, Stephen J.; Fuller, Alan M.; Klacka, Robert; Reinders, Martin; Schwind, Francis; Sullivan, Brian; hide

    2012-01-01

    In response to the Columbia Accident Investigation Board report, a plug repair kit has been developed to enable astronauts to repair the space shuttle's wing leading edge (WLE) during orbit. The plug repair kit consists of several 17.78- cm-diameter carbon/silicon carbide (C/SiC) cover plates of various curvatures that can be attached to the refractory carbon-carbon WLE panels using a TZM refractory metal attach mechanism. The attach mechanism is inserted through the damage in the WLE panel and, as it is tightened, the cover plate flexes to conform to the curvature of the WLE panel within 0.050 mm. An astronaut installs the repair during an extravehicular activity (EVA). After installing the plug repair, edge gaps are checked and the perimeter of the repair is sealed using a proprietary material, developed to fill cracks and small holes in the WLE.

  6. Dissemination of compressed satellite imagery within the Navy SPAWAR Central Site Product Display environment

    NASA Technical Reports Server (NTRS)

    Kiselyov, Oleg; Fisher, Paul

    1995-01-01

    This paper presents a case study of integration of compression techniques within a satellite image communication component of an actual tactical weather information dissemination system. The paper describes history and requirements of the project, and discusses the information flow, request/reply protocols, error handling, and, especially, system integration issues: specification of compression parameters and the place and time for compressor/decompressor plug-ins. A case for a non-uniform compression of satellite imagery is presented, and its implementation in the current system id demonstrated. The paper gives special attention to challenges of moving the system towards the use of standard, non-proprietary protocols (smtp and http) and new technologies (OpenDoc), and reports the ongoing work in this direction.

  7. Manipulating waves with LEGO bricks: A versatile experimental platform for metamaterial architectures

    NASA Astrophysics Data System (ADS)

    Celli, Paolo; Gonella, Stefano

    2015-08-01

    In this letter, we discuss a versatile, fully reconfigurable experimental platform for the investigation of phononic phenomena in metamaterial architectures. The approach revolves around the use of 3D laser vibrometry to reconstruct global and local wavefield features in specimens obtained through simple arrangements of LEGO® bricks on a thin baseplate. The agility by which it is possible to reconfigure the brick patterns into a nearly endless spectrum of topologies makes this an effective approach for rapid experimental proof of concept, as well as a powerful didactic tool, in the arena of phononic crystals and metamaterials engineering. We use our platform to provide a compelling visual illustration of important spatial wave manipulation effects (waveguiding and seismic isolation), and to elucidate fundamental dichotomies between Bragg-based and locally resonant bandgap mechanisms.

  8. Analysis of photopole data reduction models

    NASA Technical Reports Server (NTRS)

    Cheek, James B.

    1987-01-01

    An analysis of the total impulse obtained from a buried explosive charge can be calculated from displacement versus time points taken from successive film frames of high speed motion pictures of the explosive event. The indicator of that motion is a pole and baseplate (photopole), which is placed on or within the soil overburden. Here, researchers are concerned with the precision of the impulse calculation and ways to improve that precision. Also examined here is the effect of each initial condition on the curve fitting process. It is shown that the zero initial velocity criteria should not be applied due to the linear acceleration versus time character of the cubic power series. The applicability of the new method to photopole data records whose early time motions are obscured is illustrated.

  9. Low work function, stable compound clusters and generation process

    DOEpatents

    Dinh, Long N.; Balooch, Mehdi; Schildbach, Marcus A.; Hamza, Alex V.; McLean, II, William

    2000-01-01

    Low work function, stable compound clusters are generated by co-evaporation of a solid semiconductor (i.e., Si) and alkali metal (i.e., Cs) elements in an oxygen environment. The compound clusters are easily patterned during deposition on substrate surfaces using a conventional photo-resist technique. The cluster size distribution is narrow, with a peak range of angstroms to nanometers depending on the oxygen pressure and the Si source temperature. Tests have shown that compound clusters when deposited on a carbon substrate contain the desired low work function property and are stable up to 600.degree. C. Using the patterned cluster containing plate as a cathode baseplate and a faceplate covered with phosphor as an anode, one can apply a positive bias to the faceplate to easily extract electrons and obtain illumination.

  10. Fully optical backplane system using novel optical plug and slot

    NASA Astrophysics Data System (ADS)

    Cho, In-Kui; Ahn, Seung-Ho; Lee, Woo-Jin; Han, Sang-Pil; Kim, Jin-Tae; Choi, Chun-Ki; Shin, Kyung-Up; Yoon, Keun Byoung; Jeong, Myung-Yung; Park, Hyo Hoon

    2005-10-01

    A fully optical PCB with transmitter/receiver system boards and optical bakcplane was prepared, which is board-to-board interconnection by an optical slot. We report a 10 Gb/s PRBS NRZ data transmission between transmitter system board and optical backplane embedded multimode polymeric waveguide arrays. The basic concept of the optical PCB is as follows; 1) Metal optical bench is integrated with optoelectronic devices, driver and receiver circuits, polymeric waveguide and access line PCB module. 2) Multimode polymeric waveguide inside an optical backplane, which is embedded into PCB, 3) Optical slot and plug for high-density (channel pitch : 500 um) board-to-board interconnection. The polymeric waveguide technology can be used for transmission of data between transmitter/receiver processing boards and backplane boards. The main components are low-loss tapered polymeric waveguides and a novel optical plug and slot for board-to-board interconnections, respectively. The transmitter/receiver processing boards are designed as plug types, and can be easily plugged-in and -out at an optical backplane board. The optical backplane boards are prepared by employing the lamination processes for conventional electrical PCBs. A practical optical backplane system was implemented with two processing boards and an optical backplane. As connection components between the transmitter/receiver processing boards and backplane board, optical slots made of a 90°-bending structure-embedded optical plug was used. A 10 Gb/s data link was successfully demonstrated. The bit error rate (BER) was determined and is 5.6×10 -9(@10Gb/s) and the BER of 8 Gb/s is < 10 -12.

  11. Round window plugging in the treatment of superior semicircular canal dehiscence.

    PubMed

    Succar, Eric F; Manickam, Periakaruppan V; Wing, Sara; Walter, Jeffrey; Greene, Joseph S; Azeredo, William J

    2018-06-01

    Objectives were to describe the use of round window plugging for superior semicircular canal dehiscence syndrome and review further recommendations regarding the procedure based on our experience and to compare results with recent literature on round window plugging. Retrospective case series. Fourteen patients underwent round window plugging for superior semicircular canal dehiscence at our institution from 2012 to 2015. All patients underwent the same surgical procedure. Available pre- and postoperative data were reviewed. Fourteen patient charts were reviewed. Symptoms of autophony improved in nine of 14 (64%) patients. Symptoms of pressure-induced vertigo improved in seven of 12 (58%) patients. Hennebert's sign that was positive preoperatively only improved in one of six (17%) patients. A positive preoperative vestibular evoked myogenic potential improved in only one of six (17%) patients. Six of 13 (46%) patients had increased air conduction thresholds postoperatively. Round window plugging has been described as a less-invasive treatment for patients with superior semicircular canal dehiscence. Although the procedure did benefit some of our patients, successful outcomes were not predictable. Improvement in at least one objective finding was seen in only 21% of the patients studied. Hennebert's sign and vestibular evoked myogenic potentials that were positive preoperatively only improved in 17% of patients. At our institution, round window plugging is no longer considered a reasonable treatment option for most patients with superior semicircular canal dehiscence. We recommend that further study on this topic follow a standardized pre- and postoperative assessment. 4. Laryngoscope, 128:1445-1452, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  12. Valuation of plug-in vehicle life-cycle air emissions and oil displacement benefits

    PubMed Central

    Michalek, Jeremy J.; Chester, Mikhail; Jaramillo, Paulina; Samaras, Constantine; Shiau, Ching-Shin Norman; Lave, Lester B.

    2011-01-01

    We assess the economic value of life-cycle air emissions and oil consumption from conventional vehicles, hybrid-electric vehicles (HEVs), plug-in hybrid-electric vehicles (PHEVs), and battery electric vehicles in the US. We find that plug-in vehicles may reduce or increase externality costs relative to grid-independent HEVs, depending largely on greenhouse gas and SO2 emissions produced during vehicle charging and battery manufacturing. However, even if future marginal damages from emissions of battery and electricity production drop dramatically, the damage reduction potential of plug-in vehicles remains small compared to ownership cost. As such, to offer a socially efficient approach to emissions and oil consumption reduction, lifetime cost of plug-in vehicles must be competitive with HEVs. Current subsidies intended to encourage sales of plug-in vehicles with large capacity battery packs exceed our externality estimates considerably, and taxes that optimally correct for externality damages would not close the gap in ownership cost. In contrast, HEVs and PHEVs with small battery packs reduce externality damages at low (or no) additional cost over their lifetime. Although large battery packs allow vehicles to travel longer distances using electricity instead of gasoline, large packs are more expensive, heavier, and more emissions intensive to produce, with lower utilization factors, greater charging infrastructure requirements, and life-cycle implications that are more sensitive to uncertain, time-sensitive, and location-specific factors. To reduce air emission and oil dependency impacts from passenger vehicles, strategies to promote adoption of HEVs and PHEVs with small battery packs offer more social benefits per dollar spent. PMID:21949359

  13. Valuation of plug-in vehicle life-cycle air emissions and oil displacement benefits.

    PubMed

    Michalek, Jeremy J; Chester, Mikhail; Jaramillo, Paulina; Samaras, Constantine; Shiau, Ching-Shin Norman; Lave, Lester B

    2011-10-04

    We assess the economic value of life-cycle air emissions and oil consumption from conventional vehicles, hybrid-electric vehicles (HEVs), plug-in hybrid-electric vehicles (PHEVs), and battery electric vehicles in the US. We find that plug-in vehicles may reduce or increase externality costs relative to grid-independent HEVs, depending largely on greenhouse gas and SO(2) emissions produced during vehicle charging and battery manufacturing. However, even if future marginal damages from emissions of battery and electricity production drop dramatically, the damage reduction potential of plug-in vehicles remains small compared to ownership cost. As such, to offer a socially efficient approach to emissions and oil consumption reduction, lifetime cost of plug-in vehicles must be competitive with HEVs. Current subsidies intended to encourage sales of plug-in vehicles with large capacity battery packs exceed our externality estimates considerably, and taxes that optimally correct for externality damages would not close the gap in ownership cost. In contrast, HEVs and PHEVs with small battery packs reduce externality damages at low (or no) additional cost over their lifetime. Although large battery packs allow vehicles to travel longer distances using electricity instead of gasoline, large packs are more expensive, heavier, and more emissions intensive to produce, with lower utilization factors, greater charging infrastructure requirements, and life-cycle implications that are more sensitive to uncertain, time-sensitive, and location-specific factors. To reduce air emission and oil dependency impacts from passenger vehicles, strategies to promote adoption of HEVs and PHEVs with small battery packs offer more social benefits per dollar spent.

  14. Landscape assessment of side channel plugs and associated cumulative side channel attrition across a large river floodplain

    USGS Publications Warehouse

    Reinhold, Ann Marie; Poole, Geoffrey C.; Bramblett, Robert G.; Zale, Alexander V.; Roberts, David W.

    2018-01-01

    Determining the influences of anthropogenic perturbations on side channel dynamics in large rivers is important from both assessment and monitoring perspectives because side channels provide critical habitat to numerous aquatic species. Side channel extents are decreasing in large rivers worldwide. Although riprap and other linear structures have been shown to reduce side channel extents in large rivers, we hypothesized that small “anthropogenic plugs” (flow obstructions such as dikes or berms) across side channels modify whole-river geomorphology via accelerating side channel senescence. To test this hypothesis, we conducted a geospatial assessment, comparing digitized side channel areas from aerial photographs taken during the 1950s and 2001 along 512 km of the Yellowstone River floodplain. We identified longitudinal patterns of side channel recruitment (created/enlarged side channels) and side channel attrition (destroyed/senesced side channels) across n = 17 river sections within which channels were actively migrating. We related areal measures of recruitment and attrition to the density of anthropogenic side channel plugs across river sections. Consistent with our hypothesis, a positive spatial relationship existed between the density of anthropogenic plugs and side channel attrition, but no relationship existed between plug density and side channel recruitment. Our work highlights important linkages among side channel plugs and the persistence and restoration of side channels across floodplain landscapes. Specifically, management of small plugs represents a low-cost, high-benefit restoration opportunity to facilitate scouring flows in side channels to enable the persistence of these habitats over time.

  15. Effect of cloacal plugging on microbial recovery from partially processed broilers.

    PubMed

    Musgrove, M T; Cason, J A; Fletcher, D L; Stern, N J; Cox, N A; Bailey, J S

    1997-03-01

    Experiments were performed to test the contribution of bacteria contained in the intestinal tract of broilers at the beginning of processing to counts on the exterior of modified New York-dressed carcasses. Thirty-two birds were processed for each of seven replications. Within each replication, batches of four birds were electrocuted, scalded, and picked, with batches alternating between treatment and control groups. Treated birds were cloacally plugged with rayon fiber tampons prior to electrocution to prevent escape of intestinal contents during scalding and picking. Control birds were processed in the same manner, except that cloacal plugs were inserted immediately after defeathering to reduce escape of intestinal contents during sampling. Gram-negative enteric bacteria and Campylobacter spp. were enumerated on carcasses by whole carcass rinse procedure and in cecal contents. Counts were converted to log10 and subjected to analysis of variance. Cecal levels of Gram-negative enterics were significantly higher for plugged birds, but there was not a significant difference between levels of cecal Campylobacter spp. between treatment groups. Plugging before electrocution resulted in significantly lower levels (2.5 vs 3.0 log10 cfu/mL) of Campylobacter spp. and Gram-negative enteric bacteria (3.0 vs 3.4 log10 cfu/mL) in carcass rinses of treatment birds than in those of controls. All carcasses were positive for Gram-negative enterics. Cloacal plugging resulted in significantly lower incidence of Campylobacter spp. carcass contamination as determined by chi-square. Intestinal carriage of both campylobacters and Gram-negative enteric bacteria appears to influence the microbial quality of the carcass during processing.

  16. Oscillation of an isolated liquid plug inside a dry capillary

    NASA Astrophysics Data System (ADS)

    Srinivasan, Vyas; Kumar, Siddhartha; Asfer, Mohammed; Khandekar, Sameer

    2017-11-01

    The present work reports an experimental study on the dynamics of partially wetting isolated liquid plug (DI water), which is made to oscillate inside a square, glass capillary tube (1 mm × 1 mm; 60 mm length). The liquid plug is made to oscillate pneumatically at two different frequencies (0.25 and 0.35 Hz), using a cam-follower mechanism. Bright field imaging is used to visualize the three-phase contact line behavior, while, micro-Particle Imaging Velocimetry (PIV) apparatus is used to discern the nature of flow inside the oscillating liquid plug. During a cycle, due to the partial wetting nature of DI water, the three-phase contact line at the menisci gets pinned at the extreme end of each stroke, where the dynamic apparent contact angle gets drastically altered before the initiation of the next stroke. The difference between the apparent contact angle of the front and rear meniscus are seen to be a function of the oscillating frequency; the difference increasing with increasing frequency. The flow inside the liquid plug reveals unique non-Poiseuille flow features near the meniscus, due to free-slip boundary condition, which leads to formation of distinct vortex pairs behind it. The vortices too change their direction during each stroke of the oscillation, eventually leading to an alternating recirculation pattern inside the plug. The results clearly indicate that improved mathematical models are required for predicting transport parameters in such flows, which are important in engineering systems such as pulsating heat pipes, lab-on-chip devices and PEM fuel cells.

  17. Evaluation of Asphalt Bridge Deck Joint Systems.

    DOT National Transportation Integrated Search

    2009-12-01

    Asphaltic Plug Joint is an expansion joint that is used for new and rehabilitated bridges. It provides a smooth and watertight surface free of debris; and offers simple, easy and staged construction. Asphaltic plug joint can be repaired segmentally a...

  18. 46 CFR 39.10-5 - Incorporation by reference-TB/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., 1 rue de Varembé, Geneva, Switzerland IEC 309-1—Plugs, Socket-Outlets and Couplers for Industrial Purposes: Part 1, General Requirements, 1979 39.20-9 IEC 309-2—Plugs, Socket-Outlets and Couplers for...

  19. 46 CFR 39.10-5 - Incorporation by reference-TB/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., 1 rue de Varembé, Geneva, Switzerland IEC 309-1—Plugs, Socket-Outlets and Couplers for Industrial Purposes: Part 1, General Requirements, 1979 39.20-9 IEC 309-2—Plugs, Socket-Outlets and Couplers for...

  20. 46 CFR 39.10-5 - Incorporation by reference-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., 1 rue de Varembé, Geneva, Switzerland IEC 309-1—Plugs, Socket-Outlets and Couplers for Industrial Purposes: Part 1, General Requirements, 1979 39.20-9 IEC 309-2—Plugs, Socket-Outlets and Couplers for...

Top