The standard 20 AH battery. [for the mutlimission modular spacecraft
NASA Technical Reports Server (NTRS)
Zollner, M. T.
1977-01-01
The modular power system, which is the first intended use for the NASA standard battery, is basically a four foot by four foot by eighteen inch box which can handle a complement of three 20 ampere hour batteries or later on the intended use is for three 50 ampere hour batteries to be the full complement. The system is designed to be used as a plug on component on a multi mission modular spacecraft. It has as a design point a basically 1250 watt orbital average load. The way it breaks up in a near earth orbit it would be somewhere around 1,000 watts for everything except 10 minutes, and during any 10 minute period it may go up to a peak of 3,000 watt load. Features of the battery reviewed include criteria to store electrical energy, the battery package, the covers and cases, and electrolytes. The capacities expected are 90 percent, the average cell capacity for 24 C, 90 percent of the actual battery capacity of 19 C, and 85 percent of the actual 25 degree battery capacity at zero discharge voltage for 50 percent DOD new battery is in the vicinity expected or predicted of 26.4 volts.
Basic statistical analyses of candidate nickel-hydrogen cells for the Space Station Freedom
NASA Technical Reports Server (NTRS)
Maloney, Thomas M.; Frate, David T.
1993-01-01
Nickel-Hydrogen (Ni/H2) secondary batteries will be implemented as a power source for the Space Station Freedom as well as for other NASA missions. Consequently, characterization tests of Ni/H2 cells from Eagle-Picher, Whittaker-Yardney, and Hughes were completed at the NASA Lewis Research Center. Watt-hour efficiencies of each Ni/H2 cell were measured for regulated charge and discharge cycles as a function of temperature, charge rate, discharge rate, and state of charge. Temperatures ranged from -5 C to 30 C, charge rates ranged from C/10 to 1C, discharge rates ranged from C/10 to 2C, and states of charge ranged from 20 percent to 100 percent. Results from regression analyses and analyses of mean watt-hour efficiencies demonstrated that overall performance was best at temperatures between 10 C and 20 C while the discharge rate correlated most strongly with watt-hour efficiency. In general, the cell with back-to-back electrode arrangement, single stack, 26 percent KOH, and serrated zircar separator and the cell with a recirculating electrode arrangement, unit stack, 31 percent KOH, zircar separators performed best.
1992-10-01
8 6 Summary Specs--Backup/Peak Shaving Mission Scenarios ..... 10 7 Boil-Off Replenishment (1 2-hr missions...11 8 Hybrid Oxygen Component Sizing ................................. 23 9 Mass Fraction Concentration of Condensibles..................... 25 10 ...lOIb 4" 11" 75% 18 B. 100 watt $350,000 20 wks 10 lb 100 C. 370 watt $500,000 24 wks 10 lb 370 Sulzer Bros. Turboexpander TGL-22-11/B2 $80,000 8 mos 90
Degradation of a Multilayer Insulation Due to a Seam and a Penetration
NASA Technical Reports Server (NTRS)
Sumner, I. E.
1976-01-01
The degradation of the thermal performance of a multilayer insulation due to the presence of a seam and a penetration was studied. The multilayer insulation had 30 aluminized Mylar radiation shields with silk net spacers. The seam, an offset butt joint, caused a heat input of 0.169 watt per meter in addition to the basic insulation thermal performance of 0.388 watt per square meter obtained before the installation of the butt joint. The penetration, a fiberglass tank support strut, provided a heat input (including the degradation of the insulation) of 0.543 watt in addition to the basic insulation thermal performance of 0.452 watt per square meter obtained before the penetration.
47 CFR 90.250 - Meteor burst communications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... frequency 44.20 MHz may be used for base station operation and 45.90 MHz for remote station operation on a primary basis. The frequencies 42.40 and 44.10 MHz may be used by base and remote stations, respectively... transmitter output power shall not exceed 2000 watts for base stations and 500 watts for remote stations. (d...
NASA Technical Reports Server (NTRS)
Stanhouse, R.; Cokonis, J.; Rayl, G.
1976-01-01
Progress in an investigation of the feasibility of designing a lightweight solar array with a power-to-weight ratio of 200 watts per kilogram is described. This solar array will produce 10,000 watts of electrical power at 1 A.U. at its beginning of life (BOL), and degrade less than 20% over a three year period in interplanetary flight. A review of existing lightweight solar array system concepts is presented along with discussion pertaining to their applicable technology as it relates to a 200 watt/kilogram array. Also presented is a discussion of the candidate development solar cells being considered, and various deployable boom concepts under investigation.
The 250AH/90A active lithium-thionyl chloride cell for Centaur-G application
NASA Technical Reports Server (NTRS)
Zolla, A. E.; Tura, D. D.
1987-01-01
A high rate active Li/SOCl2 cell was designed for use in a 28 volt, 250 amp-hour space battery system. The lithium battery is being considered as a replacement of its heavier silver-zinc counterpart on board the Centaur-G booster rocket which is used to launch payloads from the Space Shuttle cargo bay into deep-space. Basically a feasibility study, this development effort is demonstrating the ability of the lithium cell to deliver up to 90 amps safely at power densities of approximately 25 watts per pound. Test data on 4 prototype units is showing an energy density of 85 watt-hours per pound and 9.0 watt-hours/cu in. The cells tested typically delivered 280 to 300 amp-hours under ambient temperature test conditions using alternating continuous loads of 90, 55, and 20 amperes throughout life. Data from four cells tested are presented to demonstrate the capability of Li/SOCl2 technology for a C/3 discharge rate in active and hermetic cell units.
Scanned Laser Illuminator/Receiver
1976-11-01
0.21/cm | | Optical Power 20 Watts i input I Optical Power 100 Watts | output ! Input Power 10 kW The oscillator ...8217.rectional due to the oscillating mirror. Again, con- siderable optical magnification is provided between object space and the scan mirror to minimize the...for a 100W (14) R. A. McClatchey, et al, " Optical Properties of the Atmosphere (Third Edition)," Air Force Cambridge Research Laboratories, Tech
CrossTalk. The Journal of Defense Software Engineering. Volume 13, Number 6, June 2000
2000-06-01
Techniques for Efficiently Generating and Testing Software This paper presents a proven process that uses advanced tools to design, develop and test... optimal software. by Keith R. Wegner Large Software Systems—Back to Basics Development methods that work on small problems seem to not scale well to...Ability Requirements for Teamwork: Implications for Human Resource Management, Journal of Management, Vol. 20, No. 2, 1994. 11. Ferguson, Pat, Watts S
PV FAQs: Does the world have enough materials for PV to help address climate change?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2005-06-01
In the ongoing discussion of what needs to be done to stabilize atmospheric CO2 by mid-century (Hoffert 1998), one possible option would be to add about 10-20 terawatts (trillion watts, or TW) of photovoltaics (PV) in place of conventional sources. PV would help because, unlike burning fossil fuels, it produces no CO2. However, 10-20 TW is an enormous amount of energy. In peak Watts, the way PV installations are generally rated, it is about 50-100 TWpeak (TWp) of PV. Would we have enough materials to make this much PV? As we explain in this PV FAQ, we think our planetmore » has enough feedstock materials for PV to meet the ''TW challenge.''« less
Initial High-Power-CW-Laser Testing of Liquid-Crystal Optical Phased Arrays
2010-02-01
During testing, the pump was operated in its "turbo" mode. The temperature was monitored by one of two devices: an Omega HH82 digital...could be investigated. The bar was controlled by an Omega CN76000 temperature controller. The temperature was monitored by the same two devices used...increased. The traces in figure 6 show the phase modulation come back to life as the power was then lowered to 20 watts, 10 watts, and after
THE TOTAL LUMINOUS EFFICIENCY OF LUMINOUS BACTERIA
Harvey, E. Newton
1925-01-01
Methods are described for measuring the light emitted by an emulsion of luminous bacteria of given thickness, and calculating the light emitted by a single bacterium, measuring 1.1 x 2.2 micra, provided there is no absorption of light in the emulsion. At the same time, the oxygen consumed by a single bacterium was measured by recording the time for the bacteria to use up .9 of the oxygen dissolved in sea water from air (20 per cent oxygen). The luminescence intensity does not diminish until the oxygen concentration falls below 2 per cent, when the luminescence diminishes rapidly. Above 2 per cent oxygen (when the oxygen dissolving in sea water from pure oxygen at 760 mm. Hg pressure = 100 per cent) the bacteria use equal amounts of oxygen in equal times, while below 2 per cent oxygen it seems very likely that rate of oxygen absorption is proportional to oxygen concentration. By measuring the time for a tube of luminous bacteria of known concentration saturated with air (20 per cent oxygen) to begin to darken (2 per cent oxygen) we can calculate the oxygen absorbed by one bacterium per second. The bacteria per cc. are counted on a blood counting slide or by a centrifugal method, after measuring the volume of a single bacterium (1.695 x 10–12 cc.). Both methods gave results in good agreement with each other. The maximum value for the light from a single bacterium was 24 x 10–14 lumens or 1.9 x 10–14 candles. The maximum value for lumen-seconds per mg. of oxygen absorbed was 14. The average value for lumen-seconds per mg. O2 was 9.25. The maximum values were selected in calculating the efficiency of light production, since some of the bacteria counted may not be producing light, although they may still be using oxygen. The "diet" of the bacteria was 60 per cent glycerol and 40 per cent peptone. To oxidize this mixture each mg. of oxygen would yield 3.38 gm. calories or 14.1 watts per second. 1 lumen per watt is therefore produced by a normal bacterium which emits 14 lumen-seconds per mg. O2 absorbed. Since the maximum lumens per watt are 640, representing 100 per cent efficiency, the total luminous efficiency if .00156. As some of the oxygen is used in respiratory oxidation which may have nothing to do with luminescence, the luminescence efficiency must be higher than 1 lumen per watt. Experiments with KCN show that this substance may reduce the oxygen consumption to 1/20 of its former value while reducing the luminescence intensity only ¼. A partial separation of respiratory from luminescence oxidations is therefore effected by KCN, and our efficiency becomes 5 lumens per watt, or .0078. This is an over-all efficiency, based on the energy value of the "fuel" of the bacteria, regarded as a power plant for producing light. It compares very favorably with the 1.6 lumens per watt of a tungsten vacuum lamp or the 3.9 lumens per watt of a tungsten nitrogen lamp, if we correct the usual values for these illuminants, based on watts at the lamp terminals, for a 20 per cent efficiency of the power plant converting the energy of coal fuel into electric current. The specific luminous emission of the bacteria is 3.14 x 10–6 lumens per cm2. One bacterium absorbs 215,000 molecules of oxygen per second and emits 1,280 quanta of light at λmax = 510µµ. If we suppose that a molecule of oxygen uniting with luminous material gives rise to the emission of 1 quantum of light energy, only 1/168 of the oxygen absorbed is used in luminescence. On this basis the efficiency becomes 168 lumens per watt or 26.2 per cent. PMID:19872192
Conceptual design for a Mercury relativity satellite
NASA Technical Reports Server (NTRS)
Bender, P. L.; Ashby, N.; Wahr, J. M.; Vincent, M. A.
1989-01-01
It was shown earlier that 1 x 10 to the -14th Doppler data and 3 cm accuracy range measurements to a small Mercury Relativity Satellite in a polar orbit with four-hour period can give high-accuracy tests of gravitational theory. A particular conceptual design has been developed for such a satellite, which would take less than 10 percent of the approach mass for a possible future Mercury Orbiter Mission. The spacecraft is similar to the Pioneer Venus Orbiter, but scaled down by about a factor four in linear dimensions. A despun antenna 30 cm in diameter is used for tracking. The transmitted power is roughly 0.2 watts at K-band and 0.5 watts at X-band. The orbit parameters for individual eight-hour arcs and the gravity field of Mercury through degree and order 10 are determined mainly from the Doppler data. A 50 MHz K-band sidetone system provides the basic ranging accuracy. The spacecraft mass is 50 kg or less.
Watt-level ~2 μm laser output in Tm3+-doped tungsten tellurite glass double-cladding fiber.
Li, Kefeng; Zhang, Guang; Hu, Lili
2010-12-15
We report, for the first time to the best of our knowledge, a watt level cw fiber laser at ~2 μm from a piece of 40-cm-long newly developed highly thulium-doped (3.76 × 10(20) ions/cm(3)) tungsten tellurite glass double cladding fiber pumped by a commercial 800 nm laser diode. The maximum output power of the fiber laser reaches 1.12 W. The slope efficiency and the optical-optical efficiency with respect to the absorbed pump are 20% and 16%, respectively. The lasing threshold is 1.46 W, and the lasing wavelength is centered at 1937 nm.
Millimeter-Wave Generation with Spiraling Electron Beams
DOT National Transportation Integrated Search
1971-02-01
An investigation has been carried out of the feasibility : of using the interaction between a thin, solid, : spiraling electron beam of 10-20kV energy and a microwave : cavity to generate watts of CW millimeter-wave power. : Experimental results are ...
76 FR 79057 - Appliance Labeling Rule
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-21
...) television labels (76 FR 1038 (Jan. 6, 2011)). The effective dates of these two final rules differ. The television label amendments, published on January 6, 2011, became effective on May 10, 2011 while the earlier... ANSI C78.20-2003 and C79.1-2002) and that uses not more than 40 watts or has a length of more than 10...
77 FR 28259 - Mailings of Lithium Batteries
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-14
... containing lithium metal or lithium-ion cells or batteries and applies regardless of quantity, size, watt... ``lithium content'' for secondary lithium-ion batteries when describing maximum quantity limits. In addition...-ion (Rechargeable) Cells and Batteries [Revise 10.20.6 as follows:] Small consumer-type lithium-ion...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-31
... subject to energy conservation standards, the manufacturers removed the product from the market... Conservation Program: Request for Exclusion of 100 Watt R20 Short Incandescent Reflector Lamp From Energy Conservation Standards AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION...
75 FR 80731 - Request for Exclusion of 120 Volt, 100 Watt R20 Short Incandescent Reflector Lamps
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-23
... petition seeks to exclude from the coverage of energy conservation standards for incandescent reflector... sought by NEMA would exclude 120 volt, 100 watt R20 short lamps from coverage of energy conservation... of its energy conservation standard as applied to this type of lamp pending the outcome of this...
Fatigue life of laser cut metals
NASA Technical Reports Server (NTRS)
Martin, M. R.
1986-01-01
Fatigue tests were conducted to determine the actual reduction in fatigue life due to weight removal for balancing by: hand grinding, low power (20 watt) Nd:glass laser, and high power (400 watt) Nd:YAG laser.
Advanced Power Conditioning System
NASA Technical Reports Server (NTRS)
Johnson, N. L.
1971-01-01
The second portion of the advanced power conditioning system development program is reported. Five 100-watt parallel power stages with majority-vote-logic feedback-regulator were breadboarded and tested to the design goals. The input voltage range was 22.1 to 57.4 volts at loads from zero to 500 watts. The maximum input ripple current was 200 mA pk-pk (not including spikes) at 511 watts load; the output voltage was 56V dc with a maximum change of 0.89 volts for all variations of line, load, and temperature; the maximum output ripple was 320 mV pk-pk at 512 watts load (dependent on filter capacitance value); the maximum efficiency was 93.9% at 212 watts and 50V dc input; the minimum efficiency was 87.2% at 80-watt load and 50V dc input; the efficiency was above 90% from 102 watts to 372 watts; the maximum excursion for an 80-watt load change was 2.1 volts with a recovery time of 7 milliseconds; and the unit performed within regulation limits from -20 C to +85 C. During the test sequence, margin tests and failure mode tests were run with no resulting degradation in performance.
47 CFR 95.855 - Transmitter effective radiated power limitation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Transmitter effective radiated power limitation. The effective radiated power (ERP) of each CTS and RTU shall... with an ERP exceeding 20 watts. No mobile RTU may transmit with an ERP exceeding 4 watts. [64 FR 59663...
47 CFR 95.855 - Transmitter effective radiated power limitation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transmitter effective radiated power limitation. The effective radiated power (ERP) of each CTS and RTU shall... with an ERP exceeding 20 watts. No mobile RTU may transmit with an ERP exceeding 4 watts. [64 FR 59663...
NASA Astrophysics Data System (ADS)
Ye, Jun; Xu, Jiangming; Song, Jiaxin; Wu, Hanshuo; Zhang, Hanwei; Wu, Jian; Zhou, Pu
2018-06-01
Through high-fidelity numerical modeling and careful system-parameter design, we demonstrate the spectral manipulation of a hundred-watt-level high-power random fiber laser (RFL) by employing a watt-level tunable optical filter. Consequently, a >100-W RFL with the spectrum-agile property is achieved. The central wavelength can be continuously tuned with a range of ∼20 nm, and the tuning range of the full width at half maximum linewidth, which is closely related to the central wavelength, covers ∼1.1 to ∼2.7 times of the minimum linewidth.
Calibration Variability of 15 High Use Life Fitness Cycle Ergometers
2013-12-02
minutes Table 6.0: ACSM Predicted 10 Minute Calories Watts 10 Min Indicated Kcal Predicted VO2 (L/Min) ACSM Predicted 10 Min...144 13 322 20 6 49 7.5 171 13.5 361 19.5 8 63 7 198 13.5 400 19.5 10 77 7 224 13 440 20 Total 71 132 197 RPM 60 60.7...min 300w Kcal/min Hours on Bike 0 45 138 285 3474 2 59 7 163 12.5 323 19 4 73 7 189 13 361 19 6 87 7 215 13 400 19.5 8 102 7.5 141
Toast, Anyone? Project Teaches Electricity Basics and Math
ERIC Educational Resources Information Center
Quagliana, David F.
2010-01-01
This article describes an electrical technology experiment that shows students how to determine the cost of using an electrical appliance. The experiment also provides good math practice and teaches basic electricity terms and concepts, such as volt, ampere, watt, kilowatt, and kilowatt-hour. This experiment could be expanded to calculate the cost…
Energy use of set-top boxes and telephony products in the U.S.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosen, Karen B.; Meier, Alan K.; Zandelin, Stefan
2001-06-01
The goal of this investigation was to estimate the 1999 energy consumption of set-top boxes and telephony products in the U.S. residential sector. Results of this study will be used to identify new energy conservation opportunities and to align programs with those opportunities. We conducted a bottom-up analysis for set-top boxes and telephony products using our own power measurements and stock and usage estimates from secondary sources. The most common set-top boxes in U.S. homes in 1999 were analog cable boxes, digital cable boxes, wireless receivers, and game consoles. According to these measurements, analog cable boxes and wireless receivers drawmore » between 10 and 15 watts, while digital cable boxes draw between 20 and 25 watts in both the Active and Standby modes. Video games used less than 2 watts in Standby mode, and about 8 watts when Active. We estimate that set-top boxes accounted for 0.7% of residential electricity use in 1999. Our investigation of telephony products included answering machines, cordless phones, cordless phone answering machine combination units, and mobile phone chargers. Answering machines, cordless phones, and combination units use between 2 and 3 watts in both the Active and Standby modes. Mobile phone chargers use about 1 watt in standby. We estimate that these telephony products account for 0.5% of U.S. residential electricity consumption. Together, set-tops and telephony constituted 1.2% of U.S. residential electricity consumption in 1999. Standby power use accounted for about 60% of this energy use. The combined total energy use of the products investigated for this study and those researched previously for this series of reports account for about 6.6% of residential electricity use in the U.S.« less
Software Engineering Institute, Annual Report 2001
2002-03-01
PSP and TSP written by Watts S . Humphrey for the Addison- Wesley SEI Series in...become SCAMPI Lead Assessors. SEI A n n u a l R epo r t fy20 0 1 • 25 CMM Pioneer: Watts S . Humphrey The effort to create the original concepts of the SW...CMM was led by SEI Fellow Watts S . Humphrey , who has had a profound impact on the field of software engineering. In February 2000, a new
Design and fabrication of solar cell modules
NASA Technical Reports Server (NTRS)
Shaughnessy, T. P.
1978-01-01
A program conducted for design, fabrication and evaluation of twelve silicon solar cell modules is described. The purpose of the program was to develop a module design consistent with the requirements and objectives of JPL specification and to also incorporate elements of new technologies under development to meet LSSA Project goals. Module development emphasized preparation of a technically and economically competitive design based upon utilization of ion implanted solar cells and a glass encapsulation system. The modules fabricated, tested and delivered were of nominal 2 X 2 foot dimensions and 20 watt minimum rating. Basic design, design rationale, performance and results of environmental testing are described.
Integrated multispectral high-power laser platform for the defeat of heat-seeking missiles
NASA Astrophysics Data System (ADS)
Tadjikov, Boris; Tsekoun, Alexei; Lyakh, Arkadiy; Maulini, Richard; Barron, Rodolfo; Patel, C. Kumar N.
2011-06-01
Quantum cascade lasers are finding rapid acceptance in many defense and security applications. Our new multispectral laser platform providing watt-level outputs near 2.0 μm, 4.0 μm and 4.6 μm in continuous wave regime at room temperature. Individual lasers are spectrally beam combined into a single output beam with excellent quality. Our rugged, compact (11 × 10 × 6.5 inches), and highly reliable, air-cooled multispectral laser platform is already finding acceptance at system level. Our uncooled devices produce > 2W at 4.6 μm and >1.5W at 4.0 μm at room temperature, and maintain watt-level output at 67°C with real wallplug efficiencies >10%. Finally, all of our QCLs undergo 100-hour pre-delivery burn-in and pass shock, vibration, and temperature testing according to MIL-STD-810G.
Radioisotope Sources of Electric Power
1973-09-20
u) watt/cm-3 O) specific activity f) curia/watt (curie/a) a) half-life c) specific power output h) years (capacity) 1) days d) watt/p Polonium - 210 ...AD/A-001 210 RADIOISOTOPE SOURCES OF ELECTRIC POWER G. M. Fradkin, et al Army Foreign Science and Technology Center Charlottesville, Virginia 20...ormed. 6v usino this effect , one may make small-sized 3ources of electrical eneruv. Batteries with direct charde collection may be used to create accel
The Jet Propulsion Laboratory low-cost solar array project, 1974-1986
NASA Technical Reports Server (NTRS)
Maycock, P. D.
1986-01-01
The overall objective of the photovoltaic program is to ensure that photovoltaic conversion systems play a significant role in the nation's energy supply by stimulating an industry capable of providing approximately 50 GWe of installed electricity generating capacity by the year 2000. In order to achieve this overall objective, several time-phased program goals have been defined. Near-term goals are to achieve photovoltaic flat-plate module or concentrator array prices of $2 per peak watt (1975 dollars) at an annual production rate of 20 peak megawatts in 1982. At this price level, energy costs should range from 100 to 200 mills/kwh. Mid-term goals are to achieve photovoltaic flat-plate module or concentrator array prices of $0.50 per peak watt (in 1975 dollars), and an annual production rate of 500 peak megawatts in 1986. Studies project that photovoltaic systems will begin to compete for both distributed and larger load-center utility-type applications and thereby open up significant markets for large-scale photovoltaic systems. Far term goals are to achieve the photovoltaic flat-plate module or concentrator array price goal of $0.10 to $0.30 per peak watt in 1990 (in 1975 dollars), and an annual production rate of 10 to 20 peak gigawatts in 2000. At this price range, energy cost should be in the range of 40 to 60 mills. kwh and be cost effective for utility applications. Achievement of these goals can make photovoltaic systems economically competitive with other energy sources for dispersed on-site applications as well as for central power generation.
10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.
Code of Federal Regulations, 2012 CFR
2012-01-01
... seasonal energy efficiency ratio (SEER in British thermal units per Watt-hour (Btu/Wh)), the heating...) Package terminal air conditioners: The energy efficiency ratio (EER in British thermal units per Watt-hour... package vertical air conditioner: The energy efficiency ratio (EER in British thermal units per Watt-hour...
10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... seasonal energy efficiency ratio (SEER in British thermal units per Watt-hour (Btu/Wh)), the heating...) Package terminal air conditioners: The energy efficiency ratio (EER in British thermal units per Watt-hour... package vertical air conditioner: The energy efficiency ratio (EER in British thermal units per Watt-hour...
NASA Technical Reports Server (NTRS)
1977-01-01
Measured performance characteristics of the transmitter experiment package (TEP) aboard the Communications Technology Satellite for the first 90 operating days in orbit are presented. The TEP consists of a nominal 200-watt output stage tube (OST), a supporting power processing system (PPS), and a variable-conductance heat pipe system (VCHPS). The OST, a traveling-wave tube augmented with a 10-stage depressed collector, has an overall saturated average efficiency of 51.5 percent and an average saturated radiofrequency (RF) output power at center-band frequency of 240 watts. The PPS operated with a measured efficiency of 86.5 percent to 88.5 percent. The VCHPS, using three pipes to conduct heat from the PPS and the body of the OST to a 52-centimeter by 124-centimeter (20.5-in. by 48.75-in.) radiator fin, maintained by the PPS baseplate temperature below 50 C for all operating conditions. The TEP performance characteristics presented include frequency response, RF output power, efficiency, and distortions. Communications characteristics were evaluated by using both video and audio modulated signals.
10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.
Code of Federal Regulations, 2014 CFR
2014-01-01
... conditioners: The energy efficiency ratio (EER in British thermal units per Watt-hour (Btu/Wh)), the cooling...) Package terminal heat pumps: The energy efficiency ratio (EER in British thermal units per Watt-hour (Btu...: The energy efficiency ratio (EER in British thermal units per Watt-hour (Btu/Wh)) and the cooling...
47 CFR 80.911 - VHF transmitter.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., and on the ship-to-shore working frequencies necessary to communicate with public coast stations... transmission of speech normally produces peak modulation within the limits 75 percent and 100 percent. (c) The transmitter must be certificated to transmit between 20 watts and 25 watts, on each of the frequencies 156.300...
Analysis of wind energy potential for agriculture pump in mountain area Aceh Besar
NASA Astrophysics Data System (ADS)
Syuhada, Ahmad; Maulana, Muhammad Ilham; Fuadi, Zahrul
2017-06-01
In this study, the potential of wind power for agricultural pump driver in Saree mountainous area of Aceh Besar is analyzed. It is found that the average usable wind speed is 6.41 m/s, which is potential to produce 893.96 Watt of electricity with the wind turbine rotor diameter of 3 m. This energy can be used to drive up to 614 Watt of water pump with static head of 20 m to irrigate 19 hectare of land, 7 hours a day. HOMER analysis indicated the lowest simulated NPC value of USD 10.028 with CoE of USD 0.717 kWh. It is also indicated that the wind has potential to produce 3452 kWh/year with lifetime of 15 years.
Solar energy in the context of energy use, energy transportation and energy storage.
MacKay, David J C
2013-08-13
Taking the UK as a case study, this paper describes current energy use and a range of sustainable energy options for the future, including solar power and other renewables. I focus on the area involved in collecting, converting and delivering sustainable energy, looking in particular detail at the potential role of solar power. Britain consumes energy at a rate of about 5000 watts per person, and its population density is about 250 people per square kilometre. If we multiply the per capita energy consumption by the population density, then we obtain the average primary energy consumption per unit area, which for the UK is 1.25 watts per square metre. This areal power density is uncomfortably similar to the average power density that could be supplied by many renewables: the gravitational potential energy of rainfall in the Scottish highlands has a raw power per unit area of roughly 0.24 watts per square metre; energy crops in Europe deliver about 0.5 watts per square metre; wind farms deliver roughly 2.5 watts per square metre; solar photovoltaic farms in Bavaria, Germany, and Vermont, USA, deliver 4 watts per square metre; in sunnier locations, solar photovoltaic farms can deliver 10 watts per square metre; concentrating solar power stations in deserts might deliver 20 watts per square metre. In a decarbonized world that is renewable-powered, the land area required to maintain today's British energy consumption would have to be similar to the area of Britain. Several other high-density, high-consuming countries are in the same boat as Britain, and many other countries are rushing to join us. Decarbonizing such countries will only be possible through some combination of the following options: the embracing of country-sized renewable power-generation facilities; large-scale energy imports from country-sized renewable facilities in other countries; population reduction; radical efficiency improvements and lifestyle changes; and the growth of non-renewable low-carbon sources, namely 'clean' coal, 'clean' gas and nuclear power. If solar is to play a large role in the future energy system, then we need new methods for energy storage; very-large-scale solar either would need to be combined with electricity stores or it would need to serve a large flexible demand for energy that effectively stores useful energy in the form of chemicals, heat, or cold.
47 CFR 22.1013 - Effective radiated power limitations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... not exceed 100 Watts. The ERP of mobile transmitters, when located within 32 kilometers (20 miles) of the 4.8 kilometer (3 mile) limit, must not exceed 25 Watts. The ERP of airborne mobile stations must.... The ERP of offshore stations located within 128.8 kilometers (80 miles) of the main transmitter...
47 CFR 22.1013 - Effective radiated power limitations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... not exceed 100 Watts. The ERP of mobile transmitters, when located within 32 kilometers (20 miles) of the 4.8 kilometer (3 mile) limit, must not exceed 25 Watts. The ERP of airborne mobile stations must.... The ERP of offshore stations located within 128.8 kilometers (80 miles) of the main transmitter...
Characteristics of Nd:YAG sculptured contact probes after prolonged laser application.
Barroso, E G; Haklin, M F; Staren, E D
1995-01-01
This study analyzed the functional and structural characteristics of cone, hemisphere, and modified sculptured contact fibers (1,000 microns) after 1 hour of continuous Nd:YAG laser application. Continuous laser application was performed on live porcine tissue using 20 watts of power. The fiber's appearance under a microscope as well as the power output was recorded after 0, 5, 10, 20, 30, 45, and 60 minutes of continuous laser application. (N = 3 for each fiber). At time 0, all fibers transmitted from 49 to 56% of the initial 20 watts (W); power transmission decreased to less than 9% relative power transmission after 20 minutes and then plateaued. The fibers exhibited severe distortion and carbonization of the surface where laser had been applied with evidence of quartz melting and shattering after only 10 minutes. By 30 minutes of laser application, all three fibers were fractured and essentially indistinguishable from one another; moreover, the fibers exhibited similar power transmission, and cutting and coagulation activity, as determined by a panel of independent, double-blinded surgeons. These data lead us to conclude that 1) Nd:YAG contact laser effects result from thermal heating of the fiber tip with subsequent tissue injury, 2) the unique structural configuration of the fiber's sculptured tip are lost after several minutes of laser application without appreciable change in functional integrity, and 3) fibers may be manually fractured allowing for multiple uses without significant sacrifice of power transmission or surgical utility.
High repetition rate, high energy, actively Q-switched all-in-fiber laser
NASA Astrophysics Data System (ADS)
Lecourt, J. B.; Bertrand, A.; Guillemet, S.; Hernandez, Y.; Giannone, D.
2010-05-01
We report an actively Q-switched Ytterbium-doped all-in-fibre laser delivering 10ns pulses with high repetition rate (from 100kHz to 1MHz). The laser operation has been validated at three different wavelengths (1040, 1050 and 1064nm). The laser can deliver up to 20Watts average power with an high beam quality (M2 = 1).
47 CFR 74.1261 - Frequency tolerance.
Code of Federal Regulations, 2014 CFR
2014-10-01
... FM Broadcast Booster Stations § 74.1261 Frequency tolerance. (a) The licensee of an FM translator or booster station with an authorized transmitter power output of 10 watts or less shall maintain the center... an FM translator or booster station with an authorized transmitter power output greater than 10 watts...
47 CFR 74.1261 - Frequency tolerance.
Code of Federal Regulations, 2012 CFR
2012-10-01
... FM Broadcast Booster Stations § 74.1261 Frequency tolerance. (a) The licensee of an FM translator or booster station with an authorized transmitter power output of 10 watts or less shall maintain the center... an FM translator or booster station with an authorized transmitter power output greater than 10 watts...
47 CFR 74.1261 - Frequency tolerance.
Code of Federal Regulations, 2011 CFR
2011-10-01
... FM Broadcast Booster Stations § 74.1261 Frequency tolerance. (a) The licensee of an FM translator or booster station with an authorized transmitter power output of 10 watts or less shall maintain the center... an FM translator or booster station with an authorized transmitter power output greater than 10 watts...
47 CFR 74.1261 - Frequency tolerance.
Code of Federal Regulations, 2013 CFR
2013-10-01
... FM Broadcast Booster Stations § 74.1261 Frequency tolerance. (a) The licensee of an FM translator or booster station with an authorized transmitter power output of 10 watts or less shall maintain the center... an FM translator or booster station with an authorized transmitter power output greater than 10 watts...
Rocket Propulsion (RP) 21 Steering Committee Meeting - NASA Spacecraft Propulsion Update
NASA Technical Reports Server (NTRS)
Klem, Mark
2016-01-01
Lander Tech is three separate but synergistic efforts: Lunar CATALYST (Lunar Cargo Transportation and Landing by Soft Touchdown) Support U.S. industry led robotic lunar lander development via three public-private efforts. Support U.S. industry led robotic lunar lander development via three public-private partnerships. Infuse or transfer landing technologies into these public private partnerships. Advanced Exploration Systems-Automated Propellant Loading (APL) -Integrated Ground Operations. Demonstrate LH2 zero loss storage, loading and transfer operations via testing on a large scale in a relevant launch vehicle servicing environment. (KSC, GRC). Game Changing Technology-20 Kelvin -20 Watt Cryocooler Development of a Reverse Turbo-Brayton Cryocooler operating at 20 Kelvin with 20 Watts of refrigeration lift.
A 200 Watt Traveling Wave-Tube for the Communications Technology Satellite
NASA Technical Reports Server (NTRS)
Jones, C. L.
1976-01-01
This final report presents the results of the design, development, and test of experimental and production units of a PPM focused traveling wave tube (L-5394) that produces 225 watts of CW RF power over 85 MHz centered at 12.080 GHz. The tube uses a coupled cavity RF circuit with a velocity taper for greater than 26 percent basic efficiency. Overall efficiency of 50 percent is achieved by the incorporation of a multistage depressed collector designed at NASA Lewis Research Center. The collector is cooled by direct radiation to deep space. The tube was designed to be used for broadcasting power transmission from a satellite.
NASA Astrophysics Data System (ADS)
Newell, D. B.
2012-12-01
As outlined in Resolution 1 of the 24th Meeting of the General Conference on Weights and Measures (CGPM) on the future revision of the International System of Units (SI) [1], the current four SI base units the kilogram, the ampere, the kelvin and the mole, will be redefined in terms of invariants of nature. The new definitions will be based on fixed numerical values of the Planck constant (h), the elementary charge (e), the Boltzmann constant (k), and the Avogadro constant (NA), respectively. While significant progress has been made towards providing the necessary experimental results for the redefinition, some disagreement among the relevant data remain. Among the set of discrepant data towards the redefinition of the SI are the determinations of the Planck constant from the National Institute of Standards and Technology (NIST) watt balance [2] and the recent result from the National Research Council Canada (NRC) watt balance [3], with the discrepancy of roughly 2.5 parts in 107 being significantly outside the reported uncertainties. Of major concern is that the watt balance experiment is seen as a key component of a mise en pratique for the new kilogram definition, once such a redefinition takes place. The basic operational principle of a watt balance relates the Planck constant to mass, length, and time through h = mgvC, where m is the mass of an artifact mass standard, g is the local acceleration of gravity, v is a velocity, and C is a combination of frequencies and scalar constants. With the total uncertainty goal for the watt balance on the order of a few parts in 108, g needs to be determined at the location of the mass standard to parts in 109 such that its uncertainty is negligible in the final watt balance result. NIST and NRC have formed a collaborative effort to reconcile the relevant discrepant data and provide further progress towards preparing and testing a mise en pratique for the new kilogram definition. As an initial step, direct comparisons of key standards are being performed and similar components used in the operation of the watt balances are being jointly verified. To this end, a comparison between the gravitational measurement systems used in conjunction with the NIST and NRC watt balances was carried out in early 2012. The results of the comparison provide verification of the gravity values used in the recently published Planck constant determinations that play a vital role in the redefinition effort of the SI. [1] Resolution 1 of the 24th Meeting of the General Conference on Weights and Measures (CGPM) 2011 On the possible future revision of the International System of Units, Bureau International des Poids et Mesures, Paris, http://www.bipm.org/en/si/new_si/ [2] Steiner R L, Williams E R, Liu R, and Newell D B 2007 Uncertainty Improvements of the NIST Electronic Kilogram, IEEE Trans. Instrum. Meas., 56 2 592-596 [3] Steele A G, Meija J, Sanchez C A, Yang L, Wood B M, Sturgeon R E, Mester Z and Inglis A D 2012 Reconciling Planck constant determinations via watt balance and enriched-silicon measurements at NRC Canada Metrologia 49 1 L8-L10
DOT National Transportation Integrated Search
2001-02-01
The Minnesota data system includes the following basic files: Accident data (Accident File, Vehicle File, Occupant File); Roadlog File; Reference Post File; Traffic File; Intersection File; Bridge (Structures) File; and RR Grade Crossing File. For ea...
Energetics of the magnetosphere
NASA Technical Reports Server (NTRS)
Stern, D. P.
1980-01-01
The approximate magnitudes of several power inputs and energies associated with the Earth's magnetosphere will be derived. They include: Solar wind power impinging on the dayside magnetopause approximately 1.4 10 to the 13th power watt; power input to cross tail current approximately 3 10 to the 11th power watt; energy of moderate magnetic storm approximately 2 10 to the 15th power joule; power related to the flow of j approximately 1 to 3 10 to the 11th power watt; average power deposited by the aurora approximately 2 10 to the 10th power watt. Stored magnetic energy: released in a substorm approximately 1.5 10 to the 14th power joule. Compared to the above, the rate at which energy is released locally in magnetospheric regions where magnetic merging occurs is probably small. Merging is essential, however, for the existence of open field lines, which provide the most likely explanation for some major energy inputs listed here. Merging is also required if part of the open flux of the tail lobes is converted into closed flux, as seems to happen during substorms. Again, most of the energy release becomes evident only beyond the merging region, though some particles may gain appreciable energy in that region itself, if the plasma sheet is completely squeezed out and the high latitude lobes interact directly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shea, C.R.; Hefetz, Y.; Gillies, R.
1990-04-15
In order to elucidate the photophysical mechanisms of cellular phototoxicity sensitized by doxycycline, MGH-U1 human bladder carcinoma cells in vitro were treated with 20.7 microM doxycycline and irradiated with either a pulsed (lambda = 355 nm, pulse duration = 24 ps) or a continuous wave (lambda = 351 nm) laser. Cumulative radiant exposure and irradiance were systematically varied in experiments with both lasers. Phototoxicity was assessed by epifluorescence microscopy of unfixed cells using rhodamine 123 labeling of mitochondria. With the continuous wave source, the cumulative radiant exposure required for induction of phototoxic injury was independent of irradiance. With the 24-ps-pulsedmore » source, a significantly lower cumulative radiant exposure was required to induce the phototoxicity when the peak irradiance was 5.8 x 10(7) or 1.3 x 10(8) watts cm-2 compared with when peak irradiance was either lower (6.0 x 10(6) watts cm-2) or higher (7.6 x 10(8) watts cm-2). The measured fluorescence lifetimes of doxycycline in buffered saline solution were longer than the laser pulse duration of 24 ps. The increased efficiency of photosensitization at the optimal peak irradiance in the ps domain appears to result from sequential multiphoton absorption involving higher excited states of the singlet manifold. At the highest irradiance studied, on the other hand, reduced efficiency of photosensitization is attributed to increased photodegradation of doxycycline from higher excited states by processes such as photoionization. A model consistent with these observations is presented along with calculations, based on simple rate equations, that fit the essentials of the proposed model.« less
Power Supplies for Space Systems Quality Assurance by Sandia Laboratories
DOE R&D Accomplishments Database
Hannigan, R. L.; Harnar, R. R.
1976-07-01
The Sandia Laboratories` participation in Quality Assurance programs for Radioisotopic Thermoelectric Generators which have been used in space systems over the past 10 years is summarized. Basic elements of this QA program are briefly described and recognition of assistance from other Sandia organizations is included. Descriptions of the various systems for which Sandia has had the QA responsibility are presented, including SNAP 19 (Nimbus, Pioneer, Viking), SNAP 27 (Apollo), Transit, Multi Hundred Watt (LES 8/9 and MJS), and a new program, High Performance Generator Mod 3. The outlook for Sandia participation in RTG programs for the next several years is noted.
The Personal Software Process-SM (PSP-SM) Body of Knowledge, Version 1.0
2008-03-26
PSP ) methodology. Developed in 1993 by Watts S . Humphrey , the PSP is a disci- plined...specific to the various competency areas of the PSP BOK contained in Section 4 of this document is derived from the PSP books written by Watts S ...The content is drawn from the work of Watts S . Humphrey over the past decade. As PSP adoption continues to grow, it is expected that the PSP
The Personal Software Process(Trademark) (PSP(Trademark)) Body of Knowledge, Version 1.0
2005-08-01
PSP books and reports written by Watts S . Humphrey , listed in the bibliography of this...Software Process ( PSP ) methodology. Developed in 1993 by Watts S . Humphrey , the PSP is a disci- plined and structured approach to developing software. By...engineer. The content is drawn from the work of Watts S . Humphrey over the past decade. As PSP adoption continues to grow, it is expected that the PSP
Ultra-thin silicon solar cells for high performance panel applications
NASA Technical Reports Server (NTRS)
Gay, C. F.
1978-01-01
Solar cells have been fabricated which achieved the highest power to mass ratios and radiation stability yet reported for silicon devices. The thinnest cells (.04 mm) had initial efficiencies in excess of 2 watts per gram (AMO) and 1.7 watts per gram after an irradiation of 1 x 10 to the 15th equivalent 1 MeV electrons per square centimeter. The cells have been successfully interconnected by welding and filtered using a FEP bonded, ceria-doped microsheet of six mil thickness. Handling losses during cell manufacture and panel assembly may be minimized through the use of an integral reinforcing perimeter or ribs which remove almost all restrictions on cell thickness and area. Such a cell is typically composed of a main section which can be as thin as 0.015 mm and is supported at the edge by a thicker border (0.20 mm) of silicon.
20--500 watt AMTEC auxiliary electric power system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ivanenok, J.F. III; Sievers, R.K.
1996-12-31
Numerous design studies have been completed on Alkali Metal Thermal to Electric Converter (AMTEC) power systems for space applications demonstrating their substantial increase in performance. Recently design studies have been initiated to couple AMTEC power conversion with fossil fueled combustion systems. This paper describes the results of a Phase 1 SBIR effort to design an innovative, efficient, reliable, long life AMTEC Auxiliary Electric Power System (AEPS) for remote site applications (20--500 watts). The concept uses high voltage AMTEC cells, each containing 7 to 9 small electrolyte tubes, integrated with a combustor and recuperator. These multi-tube AMTEC cells are low cost,more » reliable, long life static converters. AMTEC technology is ideal for auxiliary electric power supplies that must operate reliably over a broad range of temperatures, fuel sources, power levels, and operational specifications. The simplicity, efficiency (20% systems) and modularity of this technology allow it to fill applications as varied as light-weight backpacks, remote site power supplies, and military base power. Phase 1 demonstrated the feasibility of a 20% system design, and showed that the development needs to focus on identifying long life AMTEC cell components, determining the AMTEC cell and system reliability, and demonstrating that a 20 watt AMTEC system is 3--5 times more efficient than existing systems for the same application.« less
Communication Satellites 1958 to 1986
1984-10-01
information by tracking a ground-based beacon. The payload has redundant wideband receivers and redundant transmitters, with 230 W helix type TWTs , for...70.3, International Conference on Comrounications; ICC (June 1981). , and R. H. Tamashiro, "A 20 GHz 75 Watt Helix TWT for Space...WB) All solid state except TWT 10-W output Receiver 1723.3. 1726.7 MHz (NB), 1725 HHz (WB) All solid state 14-dB noise figure Antenna 2
NASA Technical Reports Server (NTRS)
Ford, F. E.
1972-01-01
Tests were conducted on 20-Ah sealed nickel cadmium cells to evaluate initial and long-term performance at various charge rates, temperatures and voltage-control levels. An average ampere-hour recharge of 103 percent per orbit at 13 C was able to maintain cell capacity; required watt-hour recharge on an orbital basis was 8 to 10 percent greater than required ampere-hour recharge. Cells exhibited an early life burn-in characteristic. A discharge after periods of repetitive cycling yielded two voltage plateaus which were temporarily eliminated by the discharge.
Lead-oxygen closed-loop battery system
NASA Technical Reports Server (NTRS)
Britz, W. J.; Boshers, W. A.; Kaufmann, J. J.
1975-01-01
Calculations show that battery can deliver up to 35 watt-hours per pound, conventional lead-acid batteries deliver 10 to 15 watt-hours per pound. Weight reduction is due to replacement of solid lead-peroxide electrodes with metal current-collector screen, catalyst, and Teflon membrane.
29 CFR 1926.54 - Nonionizing radiation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... above: (1) Direct staring: 1 micro-watt per square centimeter; (2) Incidental observing: 1 milliwatt per square centimeter; (3) Diffused reflected light: 21/2 watts per square centimeter. (k) Laser unit in... exposed to microwave power densities in excess of 10 milliwatts per square centimeter. ...
29 CFR 1926.54 - Nonionizing radiation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... above: (1) Direct staring: 1 micro-watt per square centimeter; (2) Incidental observing: 1 milliwatt per square centimeter; (3) Diffused reflected light: 21/2 watts per square centimeter. (k) Laser unit in... exposed to microwave power densities in excess of 10 milliwatts per square centimeter. ...
29 CFR 1926.54 - Nonionizing radiation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... above: (1) Direct staring: 1 micro-watt per square centimeter; (2) Incidental observing: 1 milliwatt per square centimeter; (3) Diffused reflected light: 21/2 watts per square centimeter. (k) Laser unit in... exposed to microwave power densities in excess of 10 milliwatts per square centimeter. ...
29 CFR 1926.54 - Nonionizing radiation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... above: (1) Direct staring: 1 micro-watt per square centimeter; (2) Incidental observing: 1 milliwatt per square centimeter; (3) Diffused reflected light: 21/2 watts per square centimeter. (k) Laser unit in... exposed to microwave power densities in excess of 10 milliwatts per square centimeter. ...
Pulpotomies with CO2 laser in dogs
NASA Astrophysics Data System (ADS)
Figueiredo, Jose A. P.; Chavantes, Maria C.; Gioso, Marco A.; Pesce, Hildeberto F.; Jatene, Adib D.
1995-05-01
The aim of this study was to evaluate the clinical aspects of dental pulps submitted to shallow pulpotomy followed by CO2 laser radiation at five different procedures. For this purpose, initially 66 dogs' teeth were opened and about 2 or 3 mm of coronal dental pulp was removed. Continuous irrigation with saline solution was implemented. The teeth were randomly divided into 6 groups of 11 each. After cessation of bleeding, in group I, CO2 laser (Xanar-20, USA) was irradiated for 1 second at a power of 5 watts; in group II, 2 seconds at 3 watts; in Group III, 2 seconds at 5 watts; in Group IV, 1 second at 3 watts; in Group V, a continuous mode at 3 watts; Group VI served as a control, with no laser irradiation. The results showed no clinical differences between the 3 W and 5 W powers. Time period of irradiation exposition influenced definitively the clinical appearance of the dental pulps. Groups I and IV (1 second) were unable to stop the bleeding, which persisted over 15 minutes for all teeth. This may be due to the intense heat generated by CO2 laser, causing vasodilatation. Groups II and III displayed a similar appearance, but bleeding stopped in about 10 minutes. Group V (continuous mode) had no bleeding after irradiation, but a plasma-like liquid would come out for almost 2 minutes. When comparing to the control (Group VI), all the pulps would assume a jelly-like aspect, with black granulated tissue on the surface, covering totally the pulps of Group V and partially the other groups. The histological results will be discussed in a further study. From the data obtained, it seems that CO2 laser irradiation for pulpotomies should be done in a continuous mode, for clinical convenience in terms of time taken and effective irradiation.
47 CFR 87.131 - Power and emissions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Power and emissions. 87.131 Section 87.131 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AVIATION SERVICES..., F9D, F7D 25 watts. 3 HF H2B, J3E, J7D, J9W 6.0 kw. Aviation support VHF A3E 50 watts. Airport control...
High-performance linear arrays of YBa2Cu3O7 superconducting infrared microbolometers on silicon
NASA Astrophysics Data System (ADS)
Johnson, Burgess R.; Foote, Marc C.; Marsh, Holly A.
1995-06-01
Single detectors and linear arrays of microbolometers utilizing the superconducting transition edge of YBa(subscript 2)Cu(subscript 3)O(subscript 7) have been fabricated by micromachining on silicon wafers. A D* of 8 +/- 2 X 10(superscript 9) cm Hz(superscript 1/2)/watt has been measured on a single detector. This is the highest D* reported on any superconducting microbolometer operating at temperatures higher than about 70 K. The NEP of this device was 1.5 X 10(superscript -12) watts/Hz(superscript HLF) at 2 Hz, at a temperature of 80.7 K. The thermal time constant was 105 msec, and the detector area was 140 micrometers X 105 micrometers . The use of batch silicon processing makes fabrication of linear arrays of these detectors relatively straightforward. The measured responsivity of detectors in one such array varied by less than 20% over the 6 mm length of the 64-element linear array. This measurement shows that good uniformity can be achieved at a single operating temperature in a superconductor microbolometer array, even when the superconducting resistive transition is a sharp function of temperature. The thermal detection mechanism of these devices gives them broadband response. This makes them especially useful at long wavelengths (e.g. (lambda) > 20 micrometers ), where they provide very high sensitivity at relatively high operating temperatures.
Qian, Yu
2014-01-01
The synchronization transitions in Newman-Watts small-world neuronal networks (SWNNs) induced by time delay τ and long-range connection (LRC) probability P have been investigated by synchronization parameter and space-time plots. Four distinct parameter regions, that is, asynchronous region, transition region, synchronous region, and oscillatory region have been discovered at certain LRC probability P = 1.0 as time delay is increased. Interestingly, desynchronization is observed in oscillatory region. More importantly, we consider the spatiotemporal patterns obtained in delayed Newman-Watts SWNNs are the competition results between long-range drivings (LRDs) and neighboring interactions. In addition, for moderate time delay, the synchronization of neuronal network can be enhanced remarkably by increasing LRC probability. Furthermore, lag synchronization has been found between weak synchronization and complete synchronization as LRC probability P is a little less than 1.0. Finally, the two necessary conditions, moderate time delay and large numbers of LRCs, are exposed explicitly for synchronization in delayed Newman-Watts SWNNs.
Wavelength and energy dependent absorption of unconventional fuel mixtures
NASA Astrophysics Data System (ADS)
Khan, N.; Saleem, Z.; Mirza, A. A.
2005-11-01
Economic considerations of laser induced ignition over the normal electrical ignition of direct injected Compressed Natural Gas (CNG) engines has motivated automobile industry to go for extensive research on basic characteristics of leaner unconventional fuel mixtures to evaluate practical possibility of switching over to the emerging technologies. This paper briefly reviews the ongoing research activities on minimum ignition energy and power requirements of natural gas fuels and reports results of present laser air/CNG mixture absorption coefficient study. This study was arranged to determine the thermo-optical characteristics of high air/fuel ratio mixtures using laser techniques. We measured the absorption coefficient using four lasers of multiple wavelengths over a wide range of temperatures and pressures. The absorption coefficient of mixture was found to vary significantly over change of mixture temperature and probe laser wavelengths. The absorption coefficients of air/CNG mixtures were measured using 20 watts CW/pulsed CO2 laser at 10.6μm, Pulsed Nd:Yag laser at 1.06μm, 532 nm (2nd harmonic) and 4 mW CW HeNe laser at 645 nm and 580 nm for temperatures varying from 290 to 1000K using optical transmission loss technique.
Energy efficient fluorescent ballasts. Phase I, final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens Luminoptics Corporation
1978-06-21
The development of a high-frequency electronic (Stevens) ballast for fluorescent lamps is described. It is claimed that use of this ballast could reduce use energy consumption by 1.2 to 2.5 percent. The Stevens ballast has a basic efficiency of 29 percent when used with conventional lamps. With the more efficient lamps, the efficiency increases drastically. The conventional ballast and lamp has an efficiacy of approximately 60 to 63 lumens per watt (LPW). With the Stevens ballast the efficiacy raises to between 75 and 80 lumens per watt. When the Stevens ballast is utilized with the newer high efficiency lamps themore » efficiacy increases to 90 to 95 lumens per watt or a full 51 percent improvement over conventional coil and core ballasts and 25 percent over the best high efficiency premium coil and core ballasts. In addition to its energy savings capabilities, this high frequency fluorescent lamp ballast has the advantages that it is a true retrofit device that is directly interchangeable with the conventional coil core ballast, and it is dimmable over a wide and continuous range. (LCLC)« less
47 CFR 22.727 - Power limits for conventional rural radiotelephone transmitters.
Code of Federal Regulations, 2011 CFR
2011-10-01
... this section. (a) Maximum ERP. The effective radiated power (ERP) of central office and rural... circumstances. Frequency range (MHz) Maximum ERP (watts) 152-153 1400 157-159 150 454-455 3500 459-460 150 (b) Basic power limit. Except as provided in paragraph (d) of this section, the ERP of central office...
47 CFR 22.727 - Power limits for conventional rural radiotelephone transmitters.
Code of Federal Regulations, 2010 CFR
2010-10-01
... this section. (a) Maximum ERP. The effective radiated power (ERP) of central office and rural... circumstances. Frequency range (MHz) Maximum ERP (watts) 152-153 1400 157-159 150 454-455 3500 459-460 150 (b) Basic power limit. Except as provided in paragraph (d) of this section, the ERP of central office...
Wood, James L.
1996-01-01
il-heat-flux data were collected at a study site adjacent to a low-level radioactive-waste burial facility near Beatty, Nevada, for calendar year 1992. Data were collected in support of ongoing studies to estimate the potential for downward movement of radionuclides into the unsaturated sediments beneath waste-burial trenches at the arid facility. Data collected for the whole year include air temperature, relative humidity, vapor pressure, incident solar radiation, windspeed, wind direction, barometric pressure, and precipitation. Net radiation, soil temperature, and soil-heat flux data also were collected for part of the year. The data are summarized in tables and graphs.Instrumentation used at the site is discussed. The discussion includes the type, reported accuracy, and the mounting height of each sensor.During 1992, the hourly and 20-minute mean air temperatures ranged from -8.6 degrees Celsius, in January, to 42.3 degrees Celsius, in July. Hourly and 20-minute mean relative humidity ranged from 2 percent to 100 percent. Hourly and 20-minute mean vapor pressures ranged from 0.07 to 2.47 kilopascals. Daily maximum incident solar radiation values ranged from 115 to 1,021 watts per square meter. Daily maximum net radiation values ranged from 195 to 632 watts per square meter. Daily mean windspeed ranged from 0.6 to 8.1 meters per second. Wind direction was primarily from the northwest in fall, winter, and spring and was from the southeast, southwest, or northwest during the summer. Barometric pressures ranged from 100.16 kilopascals to 103.38 kilopascals. Total precipitation for 1992 was 165.3 millimeters, with more than 50 percent in February and March. Daily mean soil temperatures at a depth from 2 to 6 centimeters ranged from 10.7 to 39.1 degrees Celsius between June and October. Daily mean soil-heat flux at a dep*h of 8 centimeters ranged from -13.4 to 12.2 watts per square meter during the same period.
Abral, Hairul; Anugrah, Arya Satya; Hafizulhaq, Fadli; Handayani, Dian; Sugiarti, Eni; Muslimin, Ahmad Nove
2018-05-14
This paper reported the results of the characterization of jicama (Pachyrhizus erosus) starch based biocomposite reinforced with varied nanofiber fractions, i.e. 35.4, 70.8 and 106.2 μg per 10 g of starch. The nanofiber was isolated from oil palm empty fruit bunches. During preparation, the biocomposite in form of gel was sonicated using an ultrasonic probe at various powers, i.e. 0, 480, 600, 720 watt at 20 kHz for 5 min. The results show that ultrasonication results in a significant improvement in biocomposite properties for each of the nanofiber fractions. The tensile strength, moisture resistance of the 35.4 μg nanofibers biocomposite increase significantly 278, 11% respectively after 600 watt ultrasonication. Field emission scanning electron microscopy of the fracture surface of the film showed ultrasonication resulted in it becoming smoother and more compact. These results indicate that ultrasonication improves the performance of the film. Copyright © 2018 Elsevier B.V. All rights reserved.
Watt-level single-frequency tunable neodymium MOPA fiber laser operating at 915-937 nm
NASA Astrophysics Data System (ADS)
Rota-Rodrigo, S.; Gouhier, B.; Laroche, M.; Zhao, J.; Canuel, B.; Bertoldi, A.; Bouyer, P.; Traynor, N.; Cadier, B.; Robin, T.; Santarelli, G.
2018-02-01
We have developed a Watt-level single-frequency tunable fiber laser in the 915-937 nm spectral window. The laser is based on a neodymium-doped fiber master oscillator power amplifier architecture, with two amplification stages using a 20 mW extended cavity diode laser as seed. The system output power is higher than 2 W from 921 to 933 nm, with a stability better than 1.4% and a low relative intensity noise.
HAZARDS SUMMARY REPORT FOR A TWO WATT PROMETHIUM-147 FUELED THERMOELECTRIC GENERATOR
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1959-06-01
Discussions are included of the APU design, vehicle integration, Pm/sup 147/ properties, shielding requirements, hazards design criteria, statistical analysis for impact, and radiation protection. The use of Pm/sup 147/ makes possible the fabrication of an auxiliary power unit which has applications for low power space missions of <10 watts (electrical). (B.O.G.)
A Three-Line Stereo Camera Concept for Planetary Exploration
NASA Technical Reports Server (NTRS)
Sandau, Rainer; Hilbert, Stefan; Venus, Holger; Walter, Ingo; Fang, Wai-Chi; Alkalai, Leon
1997-01-01
This paper presents a low-weight stereo camera concept for planetary exploration. The camera uses three CCD lines within the image plane of one single objective. Some of the main features of the camera include: focal length-90 mm, FOV-18.5 deg, IFOV-78 (mu)rad, convergence angles-(+/-)10 deg, radiometric dynamics-14 bit, weight-2 kg, and power consumption-12.5 Watts. From an orbit altitude of 250 km the ground pixel size is 20m x 20m and the swath width is 82 km. The CCD line data is buffered in the camera internal mass memory of 1 Gbit. After performing radiometric correction and application-dependent preprocessing the data is compressed and ready for downlink. Due to the aggressive application of advanced technologies in the area of microelectronics and innovative optics, the low mass and power budgets of 2 kg and 12.5 Watts is achieved, while still maintaining high performance. The design of the proposed light-weight camera is also general purpose enough to be applicable to other planetary missions such as the exploration of Mars, Mercury, and the Moon. Moreover, it is an example of excellent international collaboration on advanced technology concepts developed at DLR, Germany, and NASA's Jet Propulsion Laboratory, USA.
High Efficiency Microwave Power Amplifier: From the Lab to Industry
NASA Technical Reports Server (NTRS)
Sims, William Herbert, III; Bell, Joseph L. (Technical Monitor)
2001-01-01
Since the beginnings of space travel, various microwave power amplifier designs have been employed. These included Class-A, -B, and -C bias arrangements. However, shared limitation of these topologies is the inherent high total consumption of input power associated with the generation of radio frequency (RF)/microwave power. The power amplifier has always been the largest drain for the limited available power on the spacecraft. Typically, the conversion efficiency of a microwave power amplifier is 10 to 20%. For a typical microwave power amplifier of 20 watts, input DC power of at least 100 watts is required. Such a large demand for input power suggests that a better method of RF/microwave power generation is required. The price paid for using a linear amplifier where high linearity is unnecessary includes higher initial and operating costs, lower DC-to-RF conversion efficiency, high power consumption, higher power dissipation and the accompanying need for higher capacity heat removal means, and an amplifier that is more prone to parasitic oscillation. The first use of a higher efficiency mode of power generation was described by Baxandall in 1959. This higher efficiency mode, Class-D, is achieved through distinct switching techniques to reduce the power losses associated with switching, conduction, and gate drive losses of a given transistor.
1993-12-01
properties which make it an attractive material for electronic devices used in high temperature and power applications. In order to make useful...remote plasma chamber. The processing parameters were a pressure of 18 mTorr and a power output of 20 Watts; a flow of 10 sccm of hydrogen gas was...Table I. Growth Conditions for the AIN films Temperature 1050 C Al evaporation temperature 1260 "C Nitrogen flow rate 3.5 sccrn Microwave power 100W
SNAP 19 Viking Program. Bimonthly technical progress report, October 1979-November 1979
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-12-01
Monitoring and evaluation of Viking 1 Lander power system data continued. The RTG series power range as measured at the PCDA was 65 to 68 watts at fin root temperatures between 280/sup 0/F and 310/sup 0/F. The Mars landed performance history of Viking 1 include both the minimum and maximum data for each of the SOL days. Monitoring and evaluation of Viking 2 Lander power system data continued. The RTG series power range as measured at the PCDA was 71 to 72 watts at fin root temperatures between 230/sup 0/F and 260/sup 0/F. The Mars landed performance history of Vikingmore » 2 include both the minimum and maximum data for each of the SOL days. The performance of both power systems continues to be very satisfactory. Power system performance data for Pioneer 10 and Pioneer 11 spacecraft were monitored through the reporting period. The estimated RTG system net power was 116 watts for Pioneer 10 and 118 watts for Pioneer Saturn. The September 1 encounter with Saturn appears to have had no deleterious effect on the RTG's of the spacecraft power system. The telemetry signals from both spacecrafts remain satisfactory.« less
A low-power, high-efficiency Ka-band TWTA
NASA Technical Reports Server (NTRS)
Curren, A. N.; Dayton, J. A., Jr.; Palmer, R. W.; Force, D. A.; Tamashiro, R. N.; Wilson, J. F.; Dombro, L.; Harvey, W. L.
1991-01-01
A NASA-sponsored program is described for developing a high-efficiency low-power TWTA operating at 32 GHz and meeting the requirements for the Cassini Mission to study Saturn. The required RF output power of the helix TWT is 10 watts, while the dc power from the spacecraft is limited to about 30 watts. The performance level permits the transmission to earth of all mission data. Several novel technologies are incorporated into the TWT to achieve this efficiency including an advanced dynamic velocity taper characterized by a nonlinear reduction in pitch in the output helix section and a multistage depressed collector employing copper electrodes treated for secondary electron-emission suppression. Preliminary program results are encouraging: RF output power of 10.6 watts is obtained at 14-mA beam current and 5.2-kV helix voltage with overall TWT efficiency exceeding 40 percent.
Stolephorus sp Behavior in Different LED (Light Emitting Diode) Color and Light Intensities
NASA Astrophysics Data System (ADS)
Fitri Aristi, D. P.; Ramadanita, I. A.; Hapsari, T. D.; Susanto, A.
2018-02-01
This research aims to observe anchovy (Stolephorus sp) behavior under different LED light intensities that affect eye physiology (cell cone structure). The materials used were Stolephorus sp taken from the waters off Jepara and 13 and 10 watt light emitting diode (LED). The research method was an experiment conducted from March through August 2015 in the waters off Jepara. Data analysis of visual histology and fish respond was carried out at the fishing gear material laboratory, anatomy and cultivate. Cone cell structure (mosaic cone) of Stolephorus sp forms a connected regular square pattern with every single cone surrounded by four double cones, which indicate that anchovies are sensitive to light. The 13 watt LED (628 lux) has faster response than the 10 watt LED (531 lux) as it has wider and higher emitting intensity, which also attracts fish to gather quicker.
A low-power, high-efficiency Ka-band TWTA
NASA Astrophysics Data System (ADS)
Curren, A. N.; Dayton, J. A., Jr.; Palmer, R. W.; Force, D. A.; Tamashiro, R. N.; Wilson, J. F.; Dombro, L.; Harvey, W. L.
1991-11-01
A NASA-sponsored program is described for developing a high-efficiency low-power TWTA operating at 32 GHz and meeting the requirements for the Cassini Mission to study Saturn. The required RF output power of the helix TWT is 10 watts, while the dc power from the spacecraft is limited to about 30 watts. The performance level permits the transmission to earth of all mission data. Several novel technologies are incorporated into the TWT to achieve this efficiency including an advanced dynamic velocity taper characterized by a nonlinear reduction in pitch in the output helix section and a multistage depressed collector employing copper electrodes treated for secondary electron-emission suppression. Preliminary program results are encouraging: RF output power of 10.6 watts is obtained at 14-mA beam current and 5.2-kV helix voltage with overall TWT efficiency exceeding 40 percent.
1987-06-05
Marshall. The Story of the U.S. Army Sianal Corps (New York. Franklin Watts, Inc., 1963). p. 5. : 1 the challenge of troop control, but clearly did...19Maz L. Marshall, ed.,The Story of the U.S.Armv Signal Corns (New York. Franklin Watts, Inc.,1%5), pp. 137-166 20 Dulany Terrett. The Signal Corns...villages, wooods , and roads, which ar always heavily shelled, should be avoided as far as possible when selecting cable routes. Communication trenches in
An investigation of error correcting techniques for OMV data
NASA Technical Reports Server (NTRS)
Ingels, Frank; Fryer, John
1992-01-01
Papers on the following topics are presented: considerations of testing the Orbital Maneuvering Vehicle (OMV) system with CLASS; OMV CLASS test results (first go around); equivalent system gain available from R-S encoding versus a desire to lower the power amplifier from 25 watts to 20 watts for OMV; command word acceptance/rejection rates for OMV; a memo concerning energy-to-noise ratio for the Viterbi-BSC Channel and the impact of Manchester coding loss; and an investigation of error correcting techniques for OMV and Advanced X-ray Astrophysics Facility (AXAF).
History and progress on accurate measurements of the Planck constant.
Steiner, Richard
2013-01-01
The measurement of the Planck constant, h, is entering a new phase. The CODATA 2010 recommended value is 6.626 069 57 × 10(-34) J s, but it has been a long road, and the trip is not over yet. Since its discovery as a fundamental physical constant to explain various effects in quantum theory, h has become especially important in defining standards for electrical measurements and soon, for mass determination. Measuring h in the International System of Units (SI) started as experimental attempts merely to prove its existence. Many decades passed while newer experiments measured physical effects that were the influence of h combined with other physical constants: elementary charge, e, and the Avogadro constant, N(A). As experimental techniques improved, the precision of the value of h expanded. When the Josephson and quantum Hall theories led to new electronic devices, and a hundred year old experiment, the absolute ampere, was altered into a watt balance, h not only became vital in definitions for the volt and ohm units, but suddenly it could be measured directly and even more accurately. Finally, as measurement uncertainties now approach a few parts in 10(8) from the watt balance experiments and Avogadro determinations, its importance has been linked to a proposed redefinition of a kilogram unit of mass. The path to higher accuracy in measuring the value of h was not always an example of continuous progress. Since new measurements periodically led to changes in its accepted value and the corresponding SI units, it is helpful to see why there were bumps in the road and where the different branch lines of research joined in the effort. Recalling the bumps along this road will hopefully avoid their repetition in the upcoming SI redefinition debates. This paper begins with a brief history of the methods to measure a combination of fundamental constants, thus indirectly obtaining the Planck constant. The historical path is followed in the section describing how the improved techniques and discoveries in quantum mechanics steadily reduced the uncertainty of h. The central part of this review describes the technical details of the watt balance technique, which is a combination of the mechanical and electronic measurements that now determine h as a direct result, i.e. not requiring measured values of additional fundamental constants. The first technical section describes the basics and some of the common details of many watt balance designs. Next is a review of the ongoing advances at the (currently) seven national metrology institutions where these experiments are pursued. A final summary of the recent h determinations of the last two decades shows how history keeps repeating itself; there is again a question of whether there is a shift in the newest results, albeit at uncertainties that are many orders of magnitude less than the original experiments. The conclusion is that there is room for further development to resolve these differences and find new ideas for a watt balance system with a more universal application. Since the next generation of watt balance experiments are expected to become kilogram realization standards, the historical record suggests that there is yet a need for proof that Planck constant results are finally reproducible at an acceptable uncertainty.
47 CFR 90.213 - Frequency stability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... range (MHz) Fixed and base stations Mobile stations Over 2 watts output power 2 watts or less output...-930 1.5 935-940 0.1 1.5 1.5 1427-1435 9 300 300 300 Above 2450 10 1 Fixed and base stations with over... stability of 5 ppm. 5 In the 150-174 MHz band, fixed and base stations with a 12.5 kHz channel bandwidth...
NASA Astrophysics Data System (ADS)
Prasetyo, Ari; Kristiawan, Budi; Danardono, Dominicus; Hadi, Syamsul
2018-03-01
Savonius turbine is one type of turbines with simple design and low manufacture. However, this turbine has a relatively low efficiency. This condition can be solved by installing fluid deflectors in the system’s circuit. The deflector is used to direct the focus of the water flow, thus increasing the torque working moment. In this study, a single stage horizontal axis Savonius water turbine was installed on a 3 inch diameter pipeline. This experiment aims to obtain optimal deflector angle design on each water discharge level. The deflector performance is analyzed through power output, TSR, and power coefficient generated by the turbine. The deflector angles tested are without deflector, 20°, 30°, 40°, and 50° with a deflector ratio of 50%. The experimental results at 10.67x10-3m3/s discharge show that turbine equipped with 30° deflector has the most optimal performance of 18.04 Watt power output, TSR of 1.12 and power coefficient 0.127. While with the same discharge, turbine without deflector produces only 9.77 Watt power output, TSR of 0.93, and power coefficient of 0.09. Thus, it can be concluded that the deflector increases power output equal to 85%.
Measurement of Impulsive Thrust from a Closed Radio Frequency Cavity in Vacuum
NASA Technical Reports Server (NTRS)
White, Harold; March, Paul; Lawrence, James; Vera, Jerry; Sylvester, Andre; Brady, David; Bailey, Paul
2016-01-01
A vacuum test campaign evaluating the impulsive thrust performance of a tapered RF test article excited in the TM212 mode at 1,937 megahertz (MHz) has been completed. The test campaign consisted of a forward thrust phase and reverse thrust phase at less than 8 x 10(exp -6) Torr vacuum with power scans at 40 watts, 60 watts, and 80 watts. The test campaign included a null thrust test effort to identify any mundane sources of impulsive thrust, however none were identified. Thrust data from forward, reverse, and null suggests that the system is consistently performing with a thrust to power ratio of 1.2 +/- 0.1 mN/kW.
Heterojunction Solid-State Devices for Millimeter-Wave Sources.
1983-10-01
technology such as MBE and/or OK-CVD will be required. Our large-signal, numerical WATT device simulations are the first to predict from basic transport...results are due to an improved method for determining semiconductor material parameters. We use a theoretical Monte Carlo materials simulation ... simulations . These calculations have helped provide insight into velocity overshoot and ballistic transport phenomena. We find that ballistic or near
Development of a 500-Watt portable generator
NASA Astrophysics Data System (ADS)
Knochenhauer, Robert John
In many commercial and recreational environments where power is unavailable, there is a need for lightweight, efficient, reasonably priced and quiet power sources that can recharge batteries for various portable devices. The current benchmark device is the Honda EU1000i, a 1000-Watt (peak) generator that weighs only 29 pounds (dry) and has a respectable noise level of 59 dB (at 7 meters) under peak power loading. The intent of this thesis study is to focus on the thermal management of a novel generator design that develops peak power of 500-Watts, weighs in at less than 20 pounds (dry) and has a reasonably low noise level at peak power loading. Through the course of this assessment, two key lessons are learned: • Liquid cooling at this scale is possible, but not practical • Renewable power sources (wind turbines and/or solar panels) are viable alternatives when used in environments that offer suitable conditions.
Advanced thermal management of high-power quantum cascade laser arrays for infrared countermeasures
NASA Astrophysics Data System (ADS)
Barletta, Philip; Diehl, Laurent; North, Mark T.; Yang, Bao; Baldasaro, Nick; Temple, Dorota
2017-10-01
Next-generation infrared countermeasure (IRCM) systems call for compact and lightweight high-power laser sources. Specifically, optical output power of tens of Watts in the mid-wave infrared (MWIR) is desired. Monolithically fabricated arrays of quantum cascade lasers (QCLs) have the potential to meet these requirements. Single MWIR QCL emitters operating in continuous wave at room temperature have demonstrated multi-Watt power levels with wall-plug efficiency of up to 20%. However, tens of Watts of output power from an array of QCLs translates into the necessity of removing hundreds of Watts per cm2, a formidable thermal management challenge. A potential thermal solution for such high-power QCL arrays is active cooling based on high-performance thin-film thermoelectric coolers (TFTECs), in conjunction with pumped porous-media heat exchangers. The use of active cooling via TFTECs makes it possible to not only pump the heat away, but also to lower the QCL junction temperature, thus improving the wall-plug efficiency of the array. TFTECs have shown the ability to pump >250W/cm2 at ΔT=0K, which is 25 times greater than that typically seen in commercially available bulk thermoelectric devices.
SNAP 19 Viking Program. Bimonthly technical progress report, February 1980-March 1980
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-01-01
Viking 1 Lander power system data has not been available during this reporting period, but summary reports indicate no anomalies in performance. Monitoring and evaluation of Viking 2 Lander power system data continued. Temperature data were similar to those 23 months ago, but combined RTG output power was down by 7 watts from the 75 watts recorded in February of 1978. On February 7, 1980, during a scheduled relay transmission the Lander 2 battery voltage dropped below 26.5 volts. With the orbiter attitude control gas supply nearly depleted and the space network stations required for Voyager encounter with Saturn latermore » this year, the final relay from Viking Lander 2 had been scheduled to take place on April 11. The attempt was made but no data were received. Power system performance data for Pioneer 10 and Pioneer Saturn (initially designated Pioneer 11) were monitored. The estimated RTG system net power was 115 watts for both, Pioneer 10 and Pioneer Saturn. The telemetry signal quality from Pioneer Saturn remains excellent. Pioneer 10, for the first time, shows a loss of signal strength.« less
Energetics of the magnetosphere, revised
NASA Technical Reports Server (NTRS)
Stern, D. P.
1984-01-01
The approximate magnitudes of power inputs and energies associated with the Earth's magnetosphere were derived. The nearest 40 R sub E of the plasma sheet current receive some 3.10 to the 11th power watt, and much of this goes to the Birkeland currents, which require 1-3 10 to the 11th power watt. Of that energy, about 30% appears as the energy of auroral particles and most of the rest as ionosphere joule heating. The ring current contains about 10 to the 15th power joule at quiet times, several times as much during magnetic storms, and the magnetic energy stored in the tail lobes is comparable. Substorm energy releases may range at 1.5 to 30 10 to the 11th power watt. Compared to these, the local energy release rate by magnetic merging in the magnetosphere is small. Merging is essential for the existence of open field lines, which make such inputs possible. Merging also seems to be implicated in substorms: most of the released energy only becomes evident far from the merging region, though some particles may gain appreciable energy in that region itself, if the plasma sheet is squeezed out completely and the high latitude lobes interact directly.
Tissue dissection using a 1470-nm diode laser and laparoscopic prototype
NASA Astrophysics Data System (ADS)
Chang, Chun-Hung; Hammerland, John; Nau, William H.; Fried, Nathaniel M.
2017-02-01
A continuous-wave, 40 Watt, 1470 nm laser was explored for rapid and precise dissection of porcine mesentery fascia and liver tissues, ex vivo. Laser energy was delivered through a 550-μm-core optical fiber inside a 5-mm-OD, laparoscopic probe, with detachable, 2 mm, sapphire ball rolling tip. Fascia tissue was cleanly dissected with scanning rates from 2.0 - 4.5 mm/s using 16 - 31W. Fascia collateral thermal damage measured as low as 180 +/- 50 μm at 4.5 mm/s scan speed. Porcine liver ablation crater depth measured up to 1010 +/- 220 μm with 30 W at 2.0 mm/s or as shallow as 80 +/- 30 μm with 10 W at 10 mm/s. Peak temperatures reached 130 °C at ball tip and 75 °C on metal jaws. The 1470-nm laser and probe show promise for laparoscopic tissue cutting and coagulation.
Qian, Yu
2014-01-01
The synchronization transitions in Newman-Watts small-world neuronal networks (SWNNs) induced by time delay and long-range connection (LRC) probability have been investigated by synchronization parameter and space-time plots. Four distinct parameter regions, that is, asynchronous region, transition region, synchronous region, and oscillatory region have been discovered at certain LRC probability as time delay is increased. Interestingly, desynchronization is observed in oscillatory region. More importantly, we consider the spatiotemporal patterns obtained in delayed Newman-Watts SWNNs are the competition results between long-range drivings (LRDs) and neighboring interactions. In addition, for moderate time delay, the synchronization of neuronal network can be enhanced remarkably by increasing LRC probability. Furthermore, lag synchronization has been found between weak synchronization and complete synchronization as LRC probability is a little less than 1.0. Finally, the two necessary conditions, moderate time delay and large numbers of LRCs, are exposed explicitly for synchronization in delayed Newman-Watts SWNNs. PMID:24810595
NASA 50 amp hour nickel cadmium battery waste heat determination
NASA Technical Reports Server (NTRS)
Mueller, V. C.
1980-01-01
A process for determining the waste heat generated in a 50-ampere-hour, nickel cadmium battery as a function of the discharge rate is described and results are discussed. The technique involved is essentially calibration of the battery as a heat transfer rate calorimeter. The tests are run at three different levels of battery activity, one at 40-watts of waste heat generated, one at 60, and one at 100. Battery inefficiency ranges from 14 to 18 percent at discharge rates of 284 to 588 watts, respectively and top-of-cell temperatures of 20 C.
Miniature thermo-electric cooled cryogenic pump
Keville, R.F.
1997-11-18
A miniature thermo-electric cooled cryogenic pump is described for removing residual water molecules from an inlet sample prior to sample analysis in a mass spectroscopy system, such as ion cyclotron resonance (ICR) mass spectroscopy. The cryogenic pump is a battery operated, low power (<1.6 watts) pump with a {Delta}T=100 C characteristic. The pump operates under vacuum pressures of 5{times}10{sup {minus}4} Torr to ultra high vacuum (UHV) conditions in the range of 1{times}10{sup {minus}7} to 3{times}10{sup {minus}9} Torr and will typically remove partial pressure, 2{times}10{sup {minus}7} Torr, residual water vapor. The cryogenic pump basically consists of an inlet flange piece, a copper heat sink with a square internal bore, four two tier Peltier (TEC) chips, a copper low temperature square cross sectional tubulation, an electronic receptacle, and an exit flange piece, with the low temperature tubulation being retained in the heat sink at a bias angle of 5{degree}, and with the TECs being positioned in parallel to each other with a positive potential being applied to the top tier thereof. 2 figs.
Miniature thermo-electric cooled cryogenic pump
Keville, Robert F.
1997-01-01
A miniature thermo-electric cooled cryogenic pump for removing residual water molecules from an inlet sample prior to sample analysis in a mass spectroscopy system, such as ion cyclotron resonance (ICR) mass spectroscopy. The cryogenic pump is a battery operated, low power (<1.6 watts) pump with a .DELTA.T=100.degree. C. characteristic. The pump operates under vacuum pressures of 5.times.10.sup.-4 Torr to ultra high vacuum (UHV) conditions in the range of 1.times.10.sup.-7 to 3.times.10.sup.-9 Torr and will typically remove partial pressure, 2.times.10.sup.-7 Torr, residual water vapor. The cryogenic pump basically consists of an inlet flange piece, a copper heat sink with a square internal bore, four two tier Peltier (TEC) chips, a copper low temperature square cross sectional tubulation, an electronic receptacle, and an exit flange piece, with the low temperature tubulation being retained in the heat sink at a bias angle of 5.degree., and with the TECs being positioned in parallel to each other with a positive potential being applied to the top tier thereof.
1987-12-15
26/6 NL I hLmEh~h AAll 1113L2 N12.20 1.0 L.8 11L25 -i4i 11111_" .... . Jiiii ~i L.i "- ’a a’a i" ’ I .a"", ."". % ."" " ," j ...propagation methods (BPM) have been developed in collaboration with J . V. Moloney of Heriot-Watt University and the following results obtained. (4) Not all of...Seaton, J . D. Valera, and G. I. Stegeman. "Integrated optics optical limiters," in Proceedings of AGARD Conference on Guided Waves in the Military
A Visit to the Computer Science Department,
1983-01-11
very small, its capabilities are not. Let’s take the F.8 micro-computer and compare it to the world’s first computer, " Eniac ", for a minute. Eniac was...than 30 tons, and filled up completely a room of 170 square meters. The F8 micro-computer on the other hand, has a volume 1/30,000th of Eniac , weighs...less than half a *kilo, has a power uptake of only 2.5 watts, but is 20 times as fast as Eniac and more than 10,000 times as reliable. "From this we can
An investigation and conceptual design of a holographic starfield and landmark tracker
NASA Technical Reports Server (NTRS)
Welch, J. D.
1973-01-01
The analysis, experiments, and design effort of this study have supported the feasibility of the basic holographic tracker concept. Image intensifiers and photoplastic recording materials were examined, along with a Polaroid rapid process silver halide material. Two reference beam, coherent optical matched filter technique was used for multiplexing spatial frequency filters for starfields. A 1 watt HeNe laser and an electro-optical readout are also considered.
SNAP 19 Viking Program. Bimonthly technical progress report, April-May 1980
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-01-01
Monitoring and evaluation of Viking Lander 1 power system data continued. The RTG series power range as measured at the PCDA was 65 to 67 watts at finroot temperatures between 280/sup 0/F and 310/sup 0/F. The Mars Lander performance history of Viking 1 include both the minimum and maximum data for each of the SOL days. Final available power system data for Viking Lander 2 are shown. Typical SOL day cycles for mission day 1193 are presented. The RTG series power ranged from 69 to 70 watts at finroot temperatures between 270/sup 0/F and 300/sup 0/F. The Mars Lander performancemore » history for Viking 2 is shown. Power system performance data for Pioneer 10 and Pioneer Saturn (initially designated Pioneer 11) were monitored through the reporting period. After adjusting for the telemetry characteristics, the estimated RTG system net power was 114 watts for both Pioneer 10 and Pioneer Saturn.« less
Technology Assessment for Future MILSATCOM Systems: The EHF Bands
1979-04-01
improvements must be pursued to provide long life (7 to 10 years), higher efficiencies and higher power. 1. Current Availability A 4-watt helix TWT ... helix TWT ), adequate bandwidth for communications applications and efficiencies of 40-50%. An example is the 200-watt tube operating at 12 GHz with an...costly than its helix counterpart. In addition, experience with coupled-cavity tubes in space is rare. Consequently, coupled-cavity TWTs will only be
Asymmetrical Pedaling Patterns in Parkinson's Disease Patients
Penko, Amanda L.; Hirsch, Joshua R.; Voelcker-Rehage, Claudia; Martin, Philip E.; Blackburn, Gordon; Alberts, Jay L.
2015-01-01
Background Approximately 1.5 million Americans are affected by Parkinson's disease [1] which includes the symptoms of postural instability and gait dysfunction. Currently, clinical evaluations of postural instability and gait dysfunction consist of a subjective rater assessment of gait patterns using items from the Unified Parkinson's Disease Rating Scale, and assessments can be insensitive to the effectiveness of medical interventions. Current research suggests the importance of cycling for Parkinson's disease patients, and while Parkinson's gait has been evaluated in previous studies, little is known about lower extremity control during cycling. The purpose of this study is to examine the lower extremity coordination patterns of Parkinson's patients during cycling. Methods Twenty five participants, ages 44-72, with a clinical diagnosis of idiopathic Parkinson's disease participated in an exercise test on a cycle ergometer that was equipped with pedal force measurements. Crank torque, crank angle and power produced by right and left leg were measured throughout the test to calculate Symmetry Index at three stages of exercise (20 Watt, 60 Watt, maximum performance). Findings Decreases in Symmetry Index were observed for average power output in Parkinson's patients as workload increased. Maximum power Symmetry Index showed a significant difference in symmetry between performance at both the 20 Watt and 60 Watt stage and the maximal resistance stage. Minimum power Symmetry Index did not show significant differences across the stages of the test. While lower extremity asymmetries were present in Parkinson's patients during pedaling, these asymmetries did not correlate to postural instability and gait dysfunction Unified Parkinson's Disease Rating Scale scores. Interpretation This pedaling analysis allows for a more sensitive measure of lower extremity function than the Unified Parkinson's Disease Rating Scale and may help to provide unique insight into current and future lower extremity function. PMID:25467810
Modulated Pulsed Laser Sources for Imaging Lidars
2007-10-01
doped PM fiber . The ytterbium ions in the fiber are cladding-pumped to their excited states using four, 6-Watt multimode lasers at 976 nm. Yh-dop...next amplified using a fiber amplifier to an average power of 10-15 Watts. A highly efficient, periodically poled nonlinear optical material will be...establish the feasibility of both pulsing a 1064 nm laser to produce enough average power to successfully seed a Yb- doped fiber amplifier so it will
Meesters, Ybe; Winthorst, Wim H; Duijzer, Wianne B; Hommes, Vanja
2016-02-18
The discovery of a novel photoreceptor in the retinal ganglion cells with a highest sensitivity of 470-490 nm blue light has led to research on the effects of short-wavelength light in humans. Several studies have explored the efficacy of monochromatic blue or blue-enriched light in the treatment of SAD. In this study, a comparison has been made between the effects of broad-wavelength light without ultraviolet (UV) wavelengths compared to narrow-band blue light in the treatment of sub-syndromal seasonal affective disorder (Sub-SAD). In a 15-day design, 48 participants suffering from Sub-SAD completed 20-minute sessions of light treatment on five consecutive days. 22 participants were given bright white-light treatment (BLT, broad-wavelength light without UV 10 000 lux, irradiance 31.7 Watt/m(2)) and 26 participants received narrow-band blue light (BLUE, 100 lux, irradiance 1.0 Watt/m(2)). All participants completed daily and weekly questionnaires concerning mood, activation, sleep quality, sleepiness and energy. Also, mood and energy levels were assessed by means of the SIGH-SAD, the primary outcome measure. On day 15, SIGH-SAD ratings were significantly lower than on day 1 (BLT 54.8 %, effect size 1.7 and BLUE 50.7 %, effect size 1.9). No statistically significant differences were found on the main outcome measures. Light treatment is an effective treatment for Sub-SAD. The use of narrow-band blue-light treatment is equally effective as bright white-light treatment. This study was registered in the Dutch Trial Register (Nederlands Trial Register TC = 4342 ) (20-12-2013).
NASA Technical Reports Server (NTRS)
Downey, Joseph A.
2004-01-01
The Jupiter Icy Moons Orbiter (JIMO) is set to launch between the years 2012 and 2015. It will possibly utilize a nuclear reactor power source and ion engines as it travels to the moons of Jupiter. The nuclear reactor will produce hundreds of kilowatts of power for propulsion, communication and various scientific instruments. Hence, the RF amplification devices aboard will be able to operate at a higher power level and data rate. The initial plan for the communications system is for an output of 1000 watts of RF power, a data rate of at least 10 megabits a second, and a frequency of 32 GHz. A higher data rate would be ideal to fully utilize the instruments aboard JIMO. At NASA Glenn, one of our roles in the JIMO project is to demonstrate RF power combining using multiple traveling wave tubes (TWT). In order for the power of separate TWT s to be combined, the RF output waves from each must be in-phase and have the same amplitude. Since different tubes act differently, we had to characterize each tube using a Network Analyzer. We took frequency sweeps and power sweeps to characterize each tube to ensure that they will behave similarly under the same conditions. The 200 watt Dornier tubes had been optimized to run at a lower power level (120 watts) for their extensive use in the ACTS program, so we also had to experiment with adjusting the voltage settings on several internal components (helix, anode, collector) of the tubes to reach the full 200 watt potential. from the ACTS program. Phase shifters and power attenuators were placed in the waveguide circuit at the inputs to the tubes so that adjustments could be made individually to match them exactly. A magic tee was used to route and combine the amplified electromagnetic RF waves on the tube output side. The demonstration of 200 watts of combined power was successful with efficiencies greater than 90% over a 500 MHz bandwidth. The next step will be to demonstrate the use of three amplifiers using two magic tees by adding a 200 watt Dornier tube to the Varian and Logimetrics combined setup for a total of 400 watts. After that we will use two 200 watt Dorniers for 400 watts and eventually four 200 watt Dornier tubes to demonstrate 800 watts. After demonstrating the success of power combining, we will need to verify the integrity of a modulated signal sent through the combined tubes. The purpose will be to see what effects separating and recombining will have on the modulated signal and also what effect it will have on combining efficiency. A Bit Error Rate (BER) will be determined by a Bit Error Rate Tester (BERT) by comparing the random information it transmits to what it receives back. The process began with two 100 watt tubes, a Varian and a Logimetrics, salvaged
Effects of choline chloride on electrodeposited Ni coating from a Watts-type bath
NASA Astrophysics Data System (ADS)
Wang, Yurong; Yang, Caihong; He, Jiawei; Wang, Wenchang; Mitsuzak, Naotoshi; Chen, Zhidong
2016-05-01
Electrodeposition of bright nickel (Ni) was carried out in a Watts-type bath. Choline chloride (ChCl) was applied as a multifunctional additive and substitute for nickel chloride (NiCl2) in a Watts-type bath. The function of ChCl was investigated through conductivity tests, anodic polarization, and cathodic polarization experiments. The studies revealed that ChCl performed well as a conducting salt, anodic activator, and cathodic inhibitor. The effects of ChCl on deposition rate, preferred orientation, grain size, surface morphology, and microhardness of Ni coatings were also studied. The deposition rate reached a maximum value of greater than 27 μm h-1 when 20 g L-1 ChCl was introduced to the bath. Using X-ray diffraction, it was confirmed that progressive addition of ChCl promoted the preferred crystal orientation modification from (2 0 0) and (2 2 0) to (1 1 1), refined grain size, and enhanced microhardness. The presence of ChCl lowered the roughness of the coating.
Feasibility study of a 110 watt per kilogram lightweight solar array system
NASA Technical Reports Server (NTRS)
Shepard, N. F.; Stahle, C. V.; Hanson, K. L.; Schneider, A.; Blomstrom, L. E.; Hansen, W. T.; Kirpich, A.
1973-01-01
The feasibility of a 10,000 watt solar array panel which has a minimum power-to-mass ratio of 110 watt/kg is discussed. The application of this ultralightweight solar array to three possible missions was investigated. With the interplanetary mission as a baseline, the constraining requirements for a geosynchronous mission and for a manned space station mission are presented. A review of existing lightweight solar array system concepts revealed that changes in the system approach are necessary to achieve the specified 110 watt/kg goal. A comprehensive review of existing component technology is presented in the areas of thin solar cells, solar cell covers, welded interconnectors, substrates and deployable booms. Advances in the state-of-the-art of solar cell and deployable boom technology were investigated. System level trade studies required to select the optimum boom bending stiffness, system aspect ratio, bus voltage level, and solar cell circuit arrangement are reported. Design analysis tasks included the thermal analysis of the solar cell blanket, thermal stress analysis of the solar cell interconnectors/substrate, and the thermostructural loading of the deployed boom.
Photocoagulation in the treatment of bleeding peptic ulcer
NASA Astrophysics Data System (ADS)
Otto, Wlodzimierz; Paczkowski, Pawel M.
1996-03-01
The authors present their experience in the endoscopic laser photocoagulation of bleeding peptic ulcer. From 1991 to June 1995, 203 patients admitted for UGI bleeding from peptic ulcer have been treated by this method. The source of bleeding was confirmed by endoscopy. The patients were divided into two groups: actively bleeding peptic ulcer (group IA and IB according to Forrest's classification) and ulcer with stigmata of recent bleeding (group IIA/IIB). The former group consisted of 106 patients, among whom over 40 percent (45 patients) presented signs of hypovolemic shock on admission. Nd:YAG laser (Surgical Laser Technologies) was used in a continuous mode with a contact (8 - 20 watts) or non-contact (over 50 watts) method of coagulation. In actively bleeding patients photocoagulation resulted in stopping the hemorrhage in 95 (90%). Recurrent bleeding occurred in 16 cases; in 9 of them it was stopped by repeated photocoagulation. In this group 18 patients required surgical intervention. The mortality was of 10.3% (11 patients). In 97 patients with recent bleeding stigmata photocoagulation provoked heavy hemorrhage in 3 (in 2 cases stopped by prolonged coagulation). In 9 of the remaining 94 patients recurrent bleeding occurred. Nine patients required surgical intervention. Mortality in this group was of 6%.
An assessment of sauger population characteristics on two Tennessee River reservoirs
Graham, Christy L.; Bettoli, Phillip William; Churchill, Timothy N.
2015-01-01
In 1992, a 356-mm minimum length limit (MLL) was enacted on Kentucky Lake and a 381-mm MLL was enacted on Watts Bar Lake, two mainstem reservoirs on the Tennessee River, in an attempt to reduce exploitation and improve the size structure of the sauger (Sander canadensis) populations. The objectives of this study were to compare sauger population characteristics immediately following (1993–1994) and 15 years after (2008–2009) the regulations took effect, examine spatial and temporal patterns in growth, examine recruitment patterns in each reservoir using a recruitment variability index (RVI), and assess the current likelihood of overfishing. Saugers were collected with experimental gill nets in each reservoir and aged using otoliths. A Beverton-Holt yield-per-recruit model was used to simulate angler yields and estimate the likelihood of growth overfishing. Recruitment overfishing was assessed by examining spawning potential ratios under various MLL and exploitation rate scenarios. The sauger population in Kentucky Lake experienced modest improvements in size and age structure over the 15 years following enactment of more restrictive harvest regulations, whereas the population in Watts Bar Lake changed very little, if at all, in terms of size and age structure. Mean lengths of age-3 sauger were significantly greater in Watts Bar Lake than in Kentucky Lake in both time periods. The RVI values indicated that between 1993 and 2009 the sauger in Kentucky Lake displayed more stable recruitment than the Watts Bar Lake population. Neither population exhibited signs of growth overfishing in 2008–09 under the current length limits; however, the Watts Bar Lake population would be susceptible to recruitment overfishing at high (>40%) exploitation rates if natural mortality was as low as 20%. These analyses have demonstrated that the Watts Bar Lake and Kentucky Lake populations, in terms of size and age structure, have remained relatively stable over 15+ years and the MLLs appear to be conserving the stocks.
NASA Technical Reports Server (NTRS)
Alario, J.
1979-01-01
Re-entrant groove technology was extended to hydrogen heat pipes. Parametric analyses are presented which optimize the theoretical design while considering the limitations of state-of-the-art extrusion technology. The 6063-T6 aluminum extrusion is 14.6 mm OD with a wall thickness of 1.66 mm and contains 20 axial grooves which surround a central 9.3 mm diameter vapor core. Each axial groove is 0.775 mm diameter with a 0.33 mm opening. An excess vapor reservoir is provided at the evaporator to minimize the pressure containment hazard during ambient storage. Modifications to the basic re-entrant groove profile resulted in improved overall performance. While the maximum heat transport capacity decreased slightly to 103 w-m the static wicking height increased markedly to 4.5 cm. The heat pipe became operational between 20 and 30 K after a cooldown from 77 K without any difficulty. Steady state performance data taken over a 19 to 23 K temperature range indicated: (1) maximum heat transport capacity of 5.4 w-m; (2) static wicking height of 1.42 cm; and (3) overall heat pipe conductance of 1.7 watts/deg C.
NASA Technical Reports Server (NTRS)
Christensen, Elmer
1985-01-01
The Flat-Plate Solar Array (FSA) Project, a Government-sponsored photovoltaics project, was initiated in January 1975 (previously named the Low-Cost Silicon Solar Array Project) to stimulate the development of PV systems for widespread use. Its goal then was to develop PV modules with 10% efficiency, a 20-year lifetime, and a selling price of $0.50 per peak watt of generating capacity (1975 dollars). It was recognized that cost reduction of PV solar-cell and module manufacturing was the key achievement needed if PV power systems were to be economically competitive for large-scale terrestrial use.
Production Program - Operational - SNAP 10A Units
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1961-08-07
This planning report is provided to describe the lead time, approximate costs, and major decisions and approvals required to enter a production program for the 500 watt SNAP 10A nuclear space power system.
NASA Astrophysics Data System (ADS)
Robinson, Ian A.
2014-04-01
The time is fast approaching when the SI unit of mass will cease to be based on a single material artefact and will instead be based upon the defined value of a fundamental constant—the Planck constant—h . This change requires that techniques exist both to determine the appropriate value to be assigned to the constant, and to measure mass in terms of the redefined unit. It is important to ensure that these techniques are accurate and reliable to allow full advantage to be taken of the stability and universality provided by the new definition and to guarantee the continuity of the world's mass measurements, which can affect the measurement of many other quantities such as energy and force. Up to now, efforts to provide the basis for such a redefinition of the kilogram were mainly concerned with resolving the discrepancies between individual implementations of the two principal techniques: the x-ray crystal density (XRCD) method [1] and the watt and joule balance methods which are the subject of this special issue. The first three papers report results from the NRC and NIST watt balance groups and the NIM joule balance group. The result from the NRC (formerly the NPL Mk II) watt balance is the first to be reported with a relative standard uncertainty below 2 × 10-8 and the NIST result has a relative standard uncertainty below 5 × 10-8. Both results are shown in figure 1 along with some previous results; the result from the NIM group is not shown on the plot but has a relative uncertainty of 8.9 × 10-6 and is consistent with all the results shown. The Consultative Committee for Mass and Related Quantities (CCM) in its meeting in 2013 produced a resolution [2] which set out the requirements for the number, type and quality of results intended to support the redefinition of the kilogram and required that there should be agreement between them. These results from NRC, NIST and the IAC may be considered to meet these requirements and are likely to be widely debated prior to a decision on redefinition. The CCM had already recognized that agreement was close and has set in place a process whereby redefinition can take place by 2018. The final decision will be in the hands of the Conférence Générale des Poids et Mesures (CGPM) but the results reported here should aid a positive decision. Figure 1. Figure 1. Results from recent measurements of the Planck constant. The reference for the results h 90 is derived from the conventional values of the Josephson constant K J-90 and the von Klitzing constant R K-90. The factor of ten improvement in uncertainty of the NRC watt balance result, over that achieved by the same apparatus at NPL a few years earlier, can be understood as a factor of five improvement arising from the elimination of an effect discovered at NPL that could not be eliminated before shipment to Canada and a factor of two arising from the considerable improvements made by NRC. Once the kilogram has been redefined, the watt and joule balances will complete their transitions from instruments that are primarily of interest to the electrical community for determining the SI electrical units from the mechanical units, to the principal methods by which an individual National Measurement Institute (NMI) can make an independent determination of the SI unit of mass and thereby contribute to the maintenance of national and international mass scales. This special issue gives an introduction to the diversity of techniques which are required for the operation of watt and joule balances. However it does not contain a review of existing balances; this was a deliberate decision, as a number of such review papers have been published in the past five years [3-7] and it was felt that it was not yet time for another. The first technique considered is that of gravimetry; the watt balance measures the weight Mg of a mass M , and to convert the measured weight into a mass, the value of the acceleration due to gravity g must be known, at the time of the weighing and at the centre of gravity of the mass. The paper by Liard and his co-authors at NRC describes how they have made this essential measurement. The accuracy of the watt balance may also depend on the alignment of the apparatus. Two papers deal with this important issue. The first, by Sanchez and his co-authors at NRC, shows that their balance is insensitive to a range of alignments and concentrates on the essential alignments that contribute directly to the overall uncertainty of the apparatus. Thomas and his co-authors at LNE describe their technique for reducing uncertainties in their watt balance by aligning its coil in the field of the magnet to minimize both horizontal forces and torques about horizontal axes. The search for discrepancies between the results from watt balances has encouraged researchers to consider possible error mechanisms arising from the secondary electrical interactions between the coil of a watt balance and other parts of the apparatus. Researchers from INRIM have two such papers: one considering magnetic interactions and the other considering electrostatic interactions. It is essential that such investigations are carried out: both to prove that the problems are understood and for the guidance of those building the next generation of watt and joule balances. The next four papers describe aspects of the construction of watt balances. The BIPM watt balance group describe the principles behind their simultaneous measurement scheme for a watt balance. The balance that they are constructing can also be used in the conventional two-phase mode and their paper describes the relative advantages and disadvantages of the two modes of operation. In a watt balance there are some advantages to precise vertical movement of the coil. The METAS group describe the two mechanisms that they have tested to achieve such motion and give the reasons for the choice of mechanism for use in the balance that they are constructing. The KRISS watt balance group are in the initial phases of the design and construction of a watt balance and their paper provides valuable information on the design that they are building. The design of the main magnet of a watt balance is critical to its successful operation, and an important assumption of watt balance operation is that the field of the magnet in moving mode is equivalent to that in weighing mode. Sutton and Clarkson from MSL describe a novel magnet which is designed to address this issue. The international prototype of the kilogram is kept in air but, after redefinition, the best realizations of the mass unit will be in vacuum. In their paper Berry and Davidson from NPL describe progress in techniques which relate mass measured in vacuum to that measured in air. Such techniques will be essential for making the results of watt and joule balance measurements available to science and industry. Both the NIST and NPL Mark II (NRC) watt balances use knife edges to act as the pivots for the beam. Knife edges suffer from hysteresis which can produce systematic offsets during weighing. In their paper Choi (KRISS) and Robinson (NPL) describe the analysis of this problem using both finite element (FEM) techniques and a stand-alone balance designed for testing knife edges. The last two papers deal with the possible future of the watt balance technique. The BIPM simultaneous measurement scheme for the watt balance was originally conceived for operation at cryogenic temperatures with a superconducting coil. In their paper de Mirandes and her co-authors describe initial work on the principles of this superconducting variant of the BIPM watt balance and concentrate on the characteristics of the superconducting coil in comparison with those of a normal coil. The final paper is a good example of serendipity in which Kibble (Independent Consultant) was designing novel watt balances based on seismometer suspensions and Robinson (NPL) had derived a set of general expressions, which are required for a watt balance to be immune to a range of common misalignments but also lead to the design of watt balances with a range of coil motions. The combination of these techniques has led to the novel watt balance designs which are described. Finally I would like to thank: the editor of Metrologia and the editorial staff of IOP Publishing, the referees who have responded rapidly to requests and have kept the issue on schedule, and the authors who have taken the time to provide a range of papers showing the breadth of the work required to build and operate watt or joule balances. References [1] Andreas B et al 2011 Determination of the Avogadro constant by counting the atoms in a 28Si crystal Phys. Rev. Lett. 106 030801 [2] BIPM 2013 Report of the 14th Meeting of the CCM Sèvres pp 34-7 [3] Steiner R 2013 History and progress on accurate measurements of the Planck constant Rep. Prog. Phys. 76 016101 [4] Stock M 2013 Watt balance experiments for the determination of the Planck constant and the redefinition of the kilogram Metrologia 50 R1-16 [5] Li S, Han B, Li Z and Lan J 2012 Precisely measuring the Planck constant by electromechanical balances Measurement 45 1-13 [6] Eichenberger A, Genevès G and Gournay P 2009 Determination of the Planck constant by means of a watt balance Eur. Phys. J. Spec. Top. 172 363-83 [7] Robinson I A 2009 Toward the redefinition of the kilogram: measurements of Planck's constant using watt balances IEEE Trans. Instrum. Meas. 58 942-8
An Overview of Electrodynamic Tether Performance in the Jovian System
NASA Technical Reports Server (NTRS)
Gallagher, Dennis; Johnson, Les; Bagenal, Fran; Moore, James
1998-01-01
The Jovian magnetosphere with its strong magnetic field and rapid planetary rotation present new opportunities and challenges for the use of electrodynamic tethers. An overview of the basic plasma physics properties of an electrodynamic tether moving through the Jovian magnetosphere is examined. Tether use for both propulsion and power generation are considered. Close to the planet, tether propulsive forces are found to be as high as 50 Newtons and power levels as high as 1 million Watts.
NASA Technical Reports Server (NTRS)
Honegger, R. J.; Remus, G. A.; Kurg, E. K.
1971-01-01
The development of a functional model water reclamation system is discussed. The system produces potable water by distillation from the urine and respiration-perspiration condensate at the normal rate generated by four men. Basic processes employed are vacuum distillation, vapor filtration, vapor phase catalytic oxidation, and condensation. The system is designed to use four 75-watt isotope heaters for distillation thermal input, and one 45-watt isotope for the catalytic oxidation unit. The system is capable of collecting and storing urine, and provides for stabilizing the urine by chemical pretreatment. The functional model system is designed for operation in a weightless condition with liquid-vapor phase separators for the evaporator still, and centrifugal separators for urine collection and vapor condensation. The system provides for storing and dispensing reclaimed potable water. The system operates in a batch mode for 40 days, with urine residues accumulating in the evaporator. The evaporator still and residue are removed to storage and replaced with a fresh still for the next 40-day period.
A Study on Watt-hour Meter Data Acquisition Method Based on RFID Technology
NASA Astrophysics Data System (ADS)
Chen, Xiangqun; Huang, Rui; Shen, Liman; Chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng
2018-03-01
Considering that traditional watt-hour meter data acquisition was subjected to the influence of distance and occlusion, a watt-hour meter data acquisition method based on RFID technology was proposed in this paper. In detail, RFID electronic tag was embedded in the watt-hour meter to identify the meter and record electric energy information, which made RFID based wireless data acquisition for watt-hour meter come true. Eventually, overall lifecycle management of watt-hour meter is realized.
Heat pipes for sodium-sulfur batteries
NASA Astrophysics Data System (ADS)
Hartenstine, John R.
1989-08-01
The objective of this program was to develop a variable conductance heat pipe (VCHP) for the thermal management of sodium-sulfur batteries. The VCHP maintains the sodium sulfur battery within a specified temperature rise limit (20 C) while the battery discharges a thermal load from 0 watts to 500 watts. A preliminary full scale thermal management design was developed for the sodium-sulfur battery, incorporating the VCHPs and supporting integration hardware. The feasibility of the VCHPs for this application was proved by test. The VCHP developed in Phase 1 utilized titanium as the heat pipe envelope material, and cesium as the heat pipe working fluid. The wick structure was axial grooves. Analysis and test indicate that the VCHP can provide the passive thermal control necessary for the sodium-sulfur battery. Test data show that with the heat input from Q = 0 watts to Q = 500 watts, the VCHP evaporator temperature increased from 350 C to 385 C. The temperature control range was higher than predicted due to working fluid vapor diffusion into the noncondensible gas and thermal axial conduction into the VCHP reservoir. Analysis has shown that by utilizing VCHPs for passive temperature control, the sodium-sulfur battery cells will have a lower axial delta-T during discharge than a current louver design. The VCHP thermal management package has the potential to be used in geosynchronous earth orbits (GEO) and low earth orbits (LEO).
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-14
... attempt to replace the same lamp that was previously installed. It is not typical consumer behavior to... energy conservation standards for certain commercial and industrial equipment and various consumer... Characteristics in Substitutes 1. Improved R20 Short Lamp 2. 60 W PAR16 Lamp 3. LED Lamps 4. Consumer Use of...
Definitize and Prepare Off-The-Shelf (OTS) Electronic Test Equipment (ETE) Specifications
1978-07-01
power consumption of the equipment shall be 30 watts. 3.5.2 Input power selection device. An input power selection device shall be provided for...36.2QCM( 14.25INIWX25.40r’’( 10 IM IHX 30 .48CM ( 121 MID 1U9.2,"M(43 IN1WX50.8CM( 20IN )HX57.15’"«I 22.5!N)D 36.8 3’"M(14.5IN IWX25.40rM( 10 IV...018 1437 3.63KG(aL8SI 2< 30 -a-MOD 11837 008 3350 8 .4KG’( 18.5L8S 1 315A 11837 008 3592 4.09KGt9L8S) OEFINITIZATITN "F OTS ETE
Tumbleweed: A New Paradigm for Surveying the Surface of Mars for In-Situ Resources
NASA Technical Reports Server (NTRS)
Kuhlman, K. R.; Behar, A. E.; Jones, J. A.; Carsey, F.; Hajos, G. A.; Flick, J. J.; Antol, J.
2004-01-01
Inflatable and rigid Tumbleweeds are wind-propelled long-range vehicles based on well-developed and field tested technology. Different Tumbleweed configurations can provide the capability to operate in varying terrains and accommodate a wide range of instrument packages making them suitable for autonomous surveys for in-situ natural resources. Tumbleweeds are lightweight and relatively inexpensive, making them very attractive for multiple deployments or piggy-backing on larger missions. Modeling and testing have shown that a 6 meter diameter Tumbleweed is capable of climbing 25 degree hills, traveling over 1 meter diameter boulders, and ranging over a thousand kilometers. Tumble-weeds have a potential payload capability of about 10 kg with approximately 10-20 Watts of power. Stopping for measurements can be accomplished using partial deflation or other braking mechanisms.
NASA Astrophysics Data System (ADS)
Charles, Christine; Liang, Wei; Raymond, Luke; Rivas-Davila, Juan; Boswell, Roderick W.
2017-08-01
A structurally supportive miniaturised low-weight (≤150 g) radiofrequency switch mode amplifier developed to power the small diameter Pocket Rocket electrothermal plasma micro-thruster called MiniPR is tested in vacuum conditions representative of space to demonstrate its suitability for use on nano-satellites such as `CubeSats'. Argon plasma characterisation is carried out by measuring the optical emission signal seen through the plenum window versus frequency (12.8-13.8 MHz) and the plenum cavity pressure increase (indicative of thrust generation from volumetric gas heating in the plasma cavity) versus power (1-15 Watts) with the amplifier operating at atmospheric pressure and a constant flow rate of 20 sccm. Vacuum testing is subsequently performed by measuring the operational frequency range of the amplifier as a function of gas flow rate. The switch mode amplifier design is finely tuned to the input impedance of the thruster ˜16 pF) to provide a power efficiency of 88 % at the resonant frequency and a direct feed to a low-loss (˜ 10 %) impedance matching network. This system provides successful plasma coupling at 1.54 Watts for all investigated flow rates (10-130 sccm) for cryogenic pumping speeds of the order of 6000 l.s^{-1} and a vacuum pressure of the order of ˜ 2x10^{-5} Torr during operation. Interestingly, the frequency bandwidth for which a plasma can be coupled increases from 0.04 to 0.4 MHz when the gas flow rate is increased, probably as a result of changes in the plasma impedance.
History and progress on accurate measurements of the Planck constant
NASA Astrophysics Data System (ADS)
Steiner, Richard
2013-01-01
The measurement of the Planck constant, h, is entering a new phase. The CODATA 2010 recommended value is 6.626 069 57 × 10-34 J s, but it has been a long road, and the trip is not over yet. Since its discovery as a fundamental physical constant to explain various effects in quantum theory, h has become especially important in defining standards for electrical measurements and soon, for mass determination. Measuring h in the International System of Units (SI) started as experimental attempts merely to prove its existence. Many decades passed while newer experiments measured physical effects that were the influence of h combined with other physical constants: elementary charge, e, and the Avogadro constant, NA. As experimental techniques improved, the precision of the value of h expanded. When the Josephson and quantum Hall theories led to new electronic devices, and a hundred year old experiment, the absolute ampere, was altered into a watt balance, h not only became vital in definitions for the volt and ohm units, but suddenly it could be measured directly and even more accurately. Finally, as measurement uncertainties now approach a few parts in 108 from the watt balance experiments and Avogadro determinations, its importance has been linked to a proposed redefinition of a kilogram unit of mass. The path to higher accuracy in measuring the value of h was not always an example of continuous progress. Since new measurements periodically led to changes in its accepted value and the corresponding SI units, it is helpful to see why there were bumps in the road and where the different branch lines of research joined in the effort. Recalling the bumps along this road will hopefully avoid their repetition in the upcoming SI redefinition debates. This paper begins with a brief history of the methods to measure a combination of fundamental constants, thus indirectly obtaining the Planck constant. The historical path is followed in the section describing how the improved techniques and discoveries in quantum mechanics steadily reduced the uncertainty of h. The central part of this review describes the technical details of the watt balance technique, which is a combination of the mechanical and electronic measurements that now determine h as a direct result, i.e. not requiring measured values of additional fundamental constants. The first technical section describes the basics and some of the common details of many watt balance designs. Next is a review of the ongoing advances at the (currently) seven national metrology institutions where these experiments are pursued. A final summary of the recent h determinations of the last two decades shows how history keeps repeating itself; there is again a question of whether there is a shift in the newest results, albeit at uncertainties that are many orders of magnitude less than the original experiments. The conclusion is that there is room for further development to resolve these differences and find new ideas for a watt balance system with a more universal application. Since the next generation of watt balance experiments are expected to become kilogram realization standards, the historical record suggests that there is yet a need for proof that Planck constant results are finally reproducible at an acceptable uncertainty.
Planar Monolithic Schottky Varactor Diode Millimeter-Wave Frequency Multipliers
1992-06-01
wave applications", IEEE Trans on Microwave Theory and Tech., vol. 39, no. 12, Dec. 1991 , pp. 1964-1971. A copy of this paper is 35 included in...Watts to Bulky 1991 spectral HV DC Power line Pwr Very Inguscio varies Massive 1986 with Vac.:um line Very low Gas noise Supply Ledatron Up to 1 W at...PULSED Band up to 1985 HV DC 10 GHz Massive Pwr Magnetic V?4MA > 100 GHz > 1 Watt Wide Cooling Research Quasi- McGruer Theory Theory Band Planar 1991
2007-04-26
Marc Gietter (#4929) Fuel reduction solutions for deployment of mobile electric power systems - Oerlikon Contraves , Philippe Bisaillon Eng. MEM...9,675 Whr/kg Global Commodity 8 e50 • 50 Watt Continuous Power • 12V • 100 Watt peak power • System Specifications • Dry system weight , less than 2.25...System Dry Weight 2.25kg Volume 4.5 Net System Efficiency 17% Specifications Specific Energy 3 Day Mission W-hr/kg 775 10 Day Mission W-hr/kg 1200 Goal
Prevention of CO2 laser-induced endotracheal tube fires with the laser-guard protective coating.
Sosis, M B; Dillon, F
1992-01-01
To determine how well Laser-Guard protects polyvinyl chloride (PVC) endotracheal tubes from the carbon dioxide (CO2) laser. Bare and Laser-Guard-protected PVC endotracheal tubes were tested with 5 L/min of oxygen (O2) passing through them. Research laboratory of a university-affiliated metropolitan medical center. After moistening the Laser-Guard-protected endotracheal tubes, we subjected the tubes to CO2 laser radiation at 10 and 70 watts until combustion occurred or 60 seconds had elapsed. The bare PVC tube ignited and a "blowtorch" fire occurred after 3 seconds of CO2 laser use at 70 watts. The moistened Laser-Guard-protected PVC endotracheal tubes were not significantly damaged by 1 minute of laser use at 70 watts. Laser-Guard protects the shafts of combustible PVC endotracheal tubes from direct, high-power, continuous CO2 laser radiation.
The 20 watt-hour per kilogram nickel cadmium energy storage for Intelsat V
NASA Technical Reports Server (NTRS)
Armantrout, J.
1980-01-01
The life durability of a nickel cadmium energy storage battery for the INTELSAT 5 Satellite is discussed. Configuration performance characteristics of the battery are given as well as a summary of some of the flight battery tests.
47 CFR 80.209 - Transmitter frequency tolerances.
Code of Federal Regulations, 2010 CFR
2010-10-01
... output power of 25 watts or less the frequency tolerance is 10 parts in 10 6. (b) When pulse modulation... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmitter frequency tolerances. 80.209... SERVICES STATIONS IN THE MARITIME SERVICES General Technical Standards § 80.209 Transmitter frequency...
Progress in high-power continuous-wave quantum cascade lasers [Invited].
Figueiredo, Pedro; Suttinger, Matthew; Go, Rowel; Tsvid, Eugene; Patel, C Kumar N; Lyakh, Arkadiy
2017-11-01
Multi-watt continuous-wave room temperature operation with efficiency exceeding 10% has been demonstrated for quantum cascade lasers essentially in the entire mid-wave and long-wave infrared spectral regions. Along with interband cascade lasers, these devices are the only room-temperature lasers that directly convert electrical power into mid- and long-infrared optical power. In this paper, we review the progress in high-power quantum cascade lasers made over the last 10 years. Specifically, an overview of the most important active region, waveguide, and thermal design techniques is presented, and various aspects of die packaging for high-power applications are discussed. Prospects of power scaling with lateral device dimensions for reaching optical power level in the range from 10 W to 20 W are also analyzed. Finally, coherent and spectral beam-combining techniques for very high-power infrared platforms are discussed.
Venus Surface Power and Cooling System Design
NASA Technical Reports Server (NTRS)
Landis, Geoffrey A.; Mellott, Kenneth D.
2004-01-01
A radioisotope power and cooling system is designed to provide electrical power for the a probe operating on the surface of Venus. Most foreseeable electronics devices and sensors simply cannot operate at the 450 C ambient surface temperature of Venus. Because the mission duration is substantially long and the use of thermal mass to maintain an operable temperature range is likely impractical, some type of active refrigeration may be required to keep certain components at a temperature below ambient. The fundamental cooling requirements are comprised of the cold sink temperature, the hot sink temperature, and the amount of heat to be removed. In this instance, it is anticipated that electronics would have a nominal operating temperature of 300 C. Due to the highly thermal convective nature of the high-density atmosphere, the hot sink temperature was assumed to be 50 C, which provided a 500 C temperature of the cooler's heat rejecter to the ambient atmosphere. The majority of the heat load on the cooler is from the high temperature ambient surface environment on Venus. Assuming 5 cm radial thickness of ceramic blanket insulation, the ambient heat load was estimated at approximately 77 watts. With an estimated quantity of 10 watts of heat generation from electronics and sensors, and to accommodate some level of uncertainty, the total heat load requirement was rounded up to an even 100 watts. For the radioisotope Stirling power converter configuration designed, the Sage model predicts a thermodynamic power output capacity of 478.1 watts, which slightly exceeds the required 469.1 watts. The hot sink temperature is 1200 C, and the cold sink temperature is 500 C. The required heat input is 1740 watts. This gives a thermodynamic efficiency of 27.48 %. The maximum theoretically obtainable efficiency is 47.52 %. It is estimated that the mechanical efficiency of the power converter design is on the order of 85 %, based on experimental measurements taken from 500 watt power class, laboratory-tested Stirling engines at GRC. The overall efficiency is calculated to be 23.36 %. The mass of the power converter is estimated at approximately 21.6 kg.
Microcombustor-thermoelectric power generator for 10-50 watt applications
NASA Astrophysics Data System (ADS)
Marshall, Daniel S.; Cho, Steve T.
2010-04-01
Fuel-based portable power systems, including combustion and fuel cell systems, take advantage of the 80x higher energy density of fuel over lithium battery technologies and offer the potential for much higher energy density power sources - especially for long-duration applications, such as unattended sensors. Miniaturization of fuel-based systems poses significant challenges, including processing of fuel in small channels, catalyst poisoning, and coke and soot formation. Recent advances in micro-miniature combustors in the 200Watt thermal range have enabled the development of small power sources that use the chemical energy of heavy fuel to drive thermal-to-electric converters for portable applications. CUBE Technology has developed compact Micro-Furnace combustors that efficiently deliver high-quality heat to optimized thermal-to-electric power converters, such as advanced thermoelectric power modules and Stirling motors, for portable power generation at the 10-50Watt scale. Key innovations include a compact gas-gas recuperator, innovative heavy fuel processing, coke- & soot-free operation, and combustor optimization for low balance-of-plant power use while operating at full throttle. This combustor enables the development of robust, high energy density, miniature power sources for portable applications.
Distinguished Lecture Series - Balancing the Energy & Climate Budget
None
2017-12-09
The average American uses 11400 Watts of power continuously. This is the equivalent of burning 114 x100 Watt light bulbs, all the time. The average person globally uses 2255 Watts of power, or a little less than 23 x100 Watt light bulbs.
Batteries for storage of wind-generated energy
NASA Technical Reports Server (NTRS)
Schwartz, H. J.
1973-01-01
Cost effectiveness characteristics of conventional-, metal gas-, and high energy alkali metal-batteries for wind generated energy storage are considered. A lead-acid battery with a power density of 20 to 30 watt/hours per pound is good for about 1500 charge-discharge cycles at a cost of about $80 per kilowatt hour. A zinc-chlorine battery that stores chlorine as solid chlorine hydrate at temperatures below 10 C eliminates the need to handle gaseous chlorine; its raw material cost are low and inexpensive carbon can be used for the chlorine electrode. This system has the best chance to replace lead-acid. Exotic alkali metal batteries are deemed too costly at the present stage of development.
Tumbleweed: Wind-propelled Surficial Measurements for Astrobiology and Planetary Science
NASA Technical Reports Server (NTRS)
Kuhlman, K. R.; Behar, A. E.; Jones, J. A.; Carsey, F.; Coleman, M.; Bearman, G.; Buehler, M.; Boston, P. J.; McKay, C. P.; Rothschild, L.
2004-01-01
Tumbleweed is a wind-propelled long-range vehicle based on well-developed and tested technology, instrumented to perform surveys Mars analog environments for habitability and suitable for a variety of missions on Mars. Tumbleweeds are light-weight and relatively inexpensive, making it very attractive for multiple deployments or piggy-backing on a larger mission. Tumbleweeds with rigid structures are also being developed for similar applications. Modeling and testing have shown that a 6 meter diameter Tumbleweed is capable of climbing 25 hills, traveling over 1 meter diameter boulders, and ranging over a thousand kilometers. Tumbleweeds have a potential payload capability of about 10 kilograms with approximately 10-20 Watts of power. Stopping for science investigations can also be accomplished using partial deflation or other braking mechanisms. Surveys for Astrobiology and other applications of tumbleweeds are shown.
Keck adaptive optics: control subsystem
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brase, J.M.; An, J.; Avicola, K.
1996-03-08
Adaptive optics on the Keck 10 meter telescope will provide an unprecedented level of capability in high resolution ground based astronomical imaging. The system is designed to provide near diffraction limited imaging performance with Strehl {gt} 0.3 n median Keck seeing of r0 = 25 cm, T =10 msec at 500 nm wavelength. The system will be equipped with a 20 watt sodium laser guide star to provide nearly full sky coverage. The wavefront control subsystem is responsible for wavefront sensing and the control of the tip-tilt and deformable mirrors which actively correct atmospheric turbulence. The spatial sampling interval formore » the wavefront sensor and deformable mirror is de=0.56 m which gives us 349 actuators and 244 subapertures. This paper summarizes the wavefront control system and discusses particular issues in designing a wavefront controller for the Keck telescope.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perry, R.B.; Fiarman, S.; Jung, E.A.
1990-10-01
This paper is the final report on DOE-OSS Task ANLE88002 Fast Air Chamber Calorimetry.'' The task objective was to design, construct, and test an isothermal air chamber calorimeter for plutonium assay of bulk samples that would meet the following requirements for sample power measurement: average sample measurement time less than 20 minutes. Measurement of samples with power output up to 10 W. Precision of better than 1% RSD for sample power greater than 1 W. Precision better than 0.010 watt SD, for sample power less than 1 W. This report gives a description of the calorimeter hardware and software andmore » discusses the test results. The instrument operating procedure, included as an appendix, gives examples of typical input/output and explains the menu driven software. Sample measurement time of less than 20 minutes was attained by pre-equilibration of the samples in low cost precision preheaters and by prediction of equilibrium measurements. Tests at the TA55 Plutonium Facility at Los Alamos National Laboratory, on typical samples, indicates that the instrument meets all the measurement requirements.« less
A Survey of State-of-the-Art LORAN-C Receivers.
1984-06-01
urvey/monitor, (T)ining, (Land, (O)therl h(inches). 7.6i N(inches). 7.5 D(inches). 12.6 VOLUM(cu.in.) 667 WEIGHT (lb): 18.1 TENP RANGE ( dog F): -67.170...Iaches): 2.8- W~inches): 12 VOLUM kv.ia.): 369 MuIGTY (2b): 6 TRW RANGS ( dog P): 3.*12z INPU VOLTACE: 4.5-50 OE RWQIRUNT (watts): g-12 DISPLAY TYPE: 2...Dinches). v4L0N(cu.in.)• WRIGHT (lb): 4.8 TEMP RANGE ( dog F): -4,+130 INPUT VOLTAGE: 10-45 POWER RRQUIRBNBNT (Watts): DISPLAY TYPE: A-N. LED, DOT
75 FR 6257 - Watts Bar Reservoir Land Management Plan, Loudon, Meigs, Rhea, and Roane Counties, TN
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-08
... on Watts Bar Reservoir (Project Operations and marginal strip) would continue to be administered by... TENNESSEE VALLEY AUTHORITY Watts Bar Reservoir Land Management Plan, Loudon, Meigs, Rhea, and... Watts Bar Reservoir in Tennessee. On November 19, 2009, the TVA Board of Directors (TVA Board) decided...
Space Environmental Effects on Thermal Control Coatings
NASA Technical Reports Server (NTRS)
OBrien, Susan K.; Workman, Gary L.
1997-01-01
The study of long term near ultra-violet (NUV) effects in a vacuum atmosphere, is a crucial element for space applications. NUV radiation causes significant changes in the reflectance of many coatings and types of materials. An ultra high vacuum NUV system was assembled in order to investigate various coatings and materials in this hostile environment. The vacuum is an ion pump that maintains a minimum vacuum in the mid 10(exp -9) range. The system has a base pressure of 10(exp -9) torr and this base pressure is maintained with the ion pump. The NUV exposure was maintained at 2-3 suns which allows accelerated NUV exposure without overheating the samples. The goal of this test was to maintain an intensity of 3.4 x 10(exp -2) Watts/cm(exp 2) which equals 2.9 NUV suns. An NUV sun is defined as 1.16 Watts/cm(exp 2) integrated over wavelength of 200-400 nanometers.
Frequency scaling with miniature COmpact MIcrowave and Coaxial ion sources
NASA Astrophysics Data System (ADS)
Sortais, Pascal; André, Thomas; Angot, Julien; Bouat, Sophie; Jacob, Josua; Lamy, Thierry; Sole, Patrick
2014-02-01
We will present recent basic developments about possible extension of the COMIC (for COmpact MIcrowave and Coaxial) devices up to 5.8 GHz in place of the present 2.45 GHz operation [P. Sortais, T. Lamy, J. Médard, J. Angot, L. Latrasse, and T. Thuillier, Rev. Sci. Instrum. 81, 02B314 (2010)]. New applications associating multiple COMIC devices for thin film deposition will be described and we will explain why an increase of the current density delivered by each individual ion source could lead to the increase of the deposition rate. For this purpose, we will present results of about two devices working at 5.8 GHz. The first one is a tiny ion source, the world smallest microwave ion source, exactly similar to COMIC but operating at 5.8 GHz with a quarter wave cavity structure and a few watts microwave power consumption. We will show that the frequency scaling effect is effective inside such small machines. The second one is a more ambitious ion source designed around a three quarter wave structure that works with a few tens of watts at 5.8 GHz.
47 CFR 20.21 - Signal boosters.
Code of Federal Regulations, 2014 CFR
2014-10-01
... operation to ensure compliance with applicable noise and gain limits and either self-correct or shut down... provide equivalent uplink and downlink gain and conducted uplink power output that is at least 0.05 watts... referenced to the booster's input port for each band of operation. (C) Booster Gain Limits. (1) The uplink...
47 CFR 20.21 - Signal boosters.
Code of Federal Regulations, 2013 CFR
2013-10-01
... operation to ensure compliance with applicable noise and gain limits and either self-correct or shut down... provide equivalent uplink and downlink gain and conducted uplink power output that is at least 0.05 watts... referenced to the booster's input port for each band of operation. (C) Booster Gain Limits. (1) The uplink...
AMTEC radioisotope power system design and analysis for Pluto Express Fly-By
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hendricks, T.J.; Huang, C.; Sievers, R.K.
1997-12-31
The Pluto Express Fly-By program requires a Radioisotope Power System (RPS) to supply spacecraft power for various internal functions and mission instruments and experiments. AMTEC (Alkali-Metal Thermal-Electric Conversion) power conversion is the DOE-selected technology for an advanced, high-efficiency RPS to power the Pluto Express Fly-By spacecraft. An AMTEC-based RPS using the General Purpose Heat Source (GPHS) has been conceptually designed to satisfy the Pluto Express power requirements. Integrated AMTEC cell and system thermal/electrical design analyses, structural design analyses, and mass analyses were performed to define an optimum system design. Using fresh radioisotope fuel at beginning of mission, the RPS producesmore » 102 watts of power, has a mass of 8.35 kg (specific power density = 12.2 watts/kg), with a system conversion efficiency of 20.3%. Mass/power scale-up estimates have also been generated, indicating that a 150-watt version of this RPS would weigh approximately 11.3 kg. This paper presents and discusses the key features of this RPS design, the design and analysis methodology, and the numerous system and AMTEC cell tradeoff studies establishing the optimum AMTEC-based RPS.« less
47 CFR 74.682 - Station identification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 4 2010-10-01 2010-10-01 false Station identification. 74.682 Section 74.682... Stations § 74.682 Station identification. (a) Each television broadcast auxiliary station operating with a transmitter output power of 1 watt or more must, when actually transmitting programs, transmit station...
NASA Technical Reports Server (NTRS)
Christensen, J. A.; Tammaru, I.
1974-01-01
The design, development, and test results are reported for an experimental PPM focused, traveling-wave tube that produces 235 watts of CW RF power over 85 MHz centered at 12.080 GHz. The tube uses a coupled cavity RF circuit with a velocity taper for greater than 30 percent basic efficiency. Overall efficiency of 51 percent is achieved by means of a nine stage depressed collector designed at NASA Lewis Research Center. This collector is cooled by direct radiation to deep space.
Development status on a TPV cylinder for combined heat and electric power for the home
NASA Astrophysics Data System (ADS)
Fraas, Lewis; Samaras, John; Huang, Han-Xiang; Seal, Michael; West, Edward
1999-03-01
Several first-generation water-cooled TPV cylinders have been built and tested. The existing units contain 380 GaSb cells mounted on 20 circuits; the design and test results on these photovoltaic converter arrays are presented here. Tested with a 1600 °C glowbar, one of these cylinders generated 990 Watts from a cell active area of 396 cm2, which is an electric power density of 2.5 Watts per cm2. A second-generation design is presented, using a new shingled circuit assembly. These shingled circuits allow for a slightly larger cylinder design with nearly double the cell active area. Using a SiC emitter operating at 1425 °C, this second-generation cylinder should produce over 1.5 kW of power with improved efficiency.
AMTEC: Current status and vision
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levy, G.C.; Hunt, T.K.; Sievers, R.K.
1997-12-31
The recent history of alkali metal thermal-to-electric conversion (AMTEC) has been tantalizing as technical advances have struck down most of the remaining barriers for realization of practical applications. AMTEC has always offered promise with its inherently noise-free, vibration-free, and high efficiency operation. Today`s AMTEC cells are also compact, lightweight and reliable, achieving near 20% conversion efficiency. Pathways have been defined that should lead to efficiencies of 30% or higher within two years. Prototype AMTEC devices are being built today for applications ranging from powering deep space probes (100--150 W) to residential appliance cogeneration (350--500 W) to remote and portable powermore » units (10--500 W). Multi-kilowatt systems may be only two years away. Current designs have power densities of 100--200 W/kg. Where is AMTEC technology at the start of the new millennium? Performance will exceed the numbers given above with the power capacity reaching 10 kW or more. These high power systems will also provide 100 volts or more when desired. Some AMTEC devices may be designed to operate at input temperatures well below that required today (800--900 C), providing more flexibility on the choice of heat source. Realization of industrial and consumer applications for AMTEDC will depend on manufacturing economies achieved through simplification of cell fabrication and high volume production. Advanced Modular Power Systems, Inc. is developing AMTEC manufacturing technology which may lead to costs under $25/watt within two years and under $1/watt eventually. At this cost, AMTEC devices will find broad consumer, and industrial applications.« less
47 CFR 101.1333 - Interference protection criteria.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Maximum EIRP Watts dBW Maximum ERP 1 Watts dBW Master 941.0-941.5 1000 30 600 27.8 Fixed Remote and Master 932.0-932.5 50 17 30 14.8 1 Where ERP = EIRP/1.64.> (ii) Maximum antenna height above average terrain... Reduction Table Antenna height above average terrain (meters) EIRP Watts dBW ERP Watts dBW Above 305 200 23...
RC64, a Rad-Hard Many-Core High-Performance DSP for Space Applications
NASA Astrophysics Data System (ADS)
Ginosar, Ran; Aviely, Peleg; Liran, Tuvia; Alon, Dov; Mandler, Alberto; Lange, Fredy; Dobkin, Reuven; Goldberg, Miki
2014-08-01
RC64, a novel rad-hard 64-core signal processing chip targets DSP performance of 75 GMACs (16bit), 150 GOPS and 20 single precision GFLOPS while dissipating less than 10 Watts. RC64 integrates advanced DSP cores with a multi-bank shared memory and a hardware scheduler, also supporting DDR2/3 memory and twelve 2.5 Gbps full duplex high speed serial links using SpaceFibre and other protocols. The programming model employs sequential fine-grain tasks and a separate task map to define task dependencies. RC64 is implemented as a 300 MHz integrated circuit on a 65nm CMOS technology, assembled in hermetically sealed ceramic CCGA624 package and qualified to the highest space standards.
Mobile communication devices causing interference in invasive and noninvasive ventilators.
Dang, Bao P; Nel, Pierre R; Gjevre, John A
2007-06-01
The aim of this study was to assess if common mobile communication systems would cause significant interference on mechanical ventilation devices and at what distances would such interference occur. We tested all the invasive and noninvasive ventilatory devices used within our region. This consisted of 2 adult mechanical ventilators, 1 portable ventilator, 2 pediatric ventilators, and 2 noninvasive positive pressure ventilatory devices. We operated the mobile devices from the 2 cellular communication systems (digital) and 1 2-way radio system used in our province at varying distances from the ventilators and looked at any interference they created. We tested the 2-way radio system, which had a fixed operation power output of 3.0 watts, the Global Systems for Mobile Communication cellular system, which had a maximum power output of 2.0 watts and the Time Division Multiple Access cellular system, which had a maximum power output of 0.2 watts on our ventilators. The ventilators were ventilating a plastic lung at fixed settings. The mobile communication devices were tested at varying distances starting at zero meter from the ventilator and in all operation modes. The 2-way radio caused the most interference on some of the ventilators, but the maximum distance of interference was 1.0 m. The Global Systems for Mobile Communication system caused significant interference only at 0 m and minor interference at 0.5 m on only 1 ventilator. The Time Division Multiple Access system caused no interference at all. Significant interference consisted of a dramatic rise and fluctuation of the respiratory rate, pressure, and positive end-expiratory pressure of the ventilators with no normalization when the mobile device was removed. From our experiment on our ventilators with the communication systems used in our province, we conclude that mobile communication devices such as cellular phones and 2-way radios are safe and cause no interference unless operated at very close distances of less than 1 meter.
Effect of sonication treatment on fibrilating snake fruit (Sallaca) frond fiber
NASA Astrophysics Data System (ADS)
Darmanto, Seno; Rochardjo, Heru S. B.; Jamasri, Widyorini, Ragil
2018-02-01
Aim of this research is to investigate influence of chemical and sonication treatment on fibrillating and mechanical properties of snake fruit frond fiber. The presence of surface impurities and the large amount of hydroxyl groups in natural fibers make less attractive for polymeric materials reinforcement. Effort to remove the impurities can be done by few treatments that consist of physical, chemical and mechanical treatment. Snake fruit frond bundle fiber were firstly subjected to chemical treatments with alkali solution, steaming at 2 bar and steam explosion at 6 bar by 40 times releasing of steam. Advanced treatment is done by flowing ultrasonic wave at 20 kHz by 90 - 210 watt. The output of fibrillation can reach fiber in range 10 - 25 nm compared with 10.72 µm in diameter for sonication and 6 bar in pressure of steam with 40x of rapidly steam release respectively.
Microwave-assisted extraction of pectin from cocoa peel
NASA Astrophysics Data System (ADS)
Sarah, M.; Hanum, F.; Rizky, M.; Hisham, M. F.
2018-02-01
Pectin is a polymer of d-galacturonate acids linked by β-1,4 glycosidic bond. This study isolates pectin from cocoa peel (Theobroma cacao) using citric acid as solvent by microwave-assisted extraction method. Cocoa peels (moisture content of 10%) with citric acid solution (pH of 1.5) irradiated by microwave energy at various microwave power (180, 300, 450 and 600 W) for 10, 15, 20, 25 and 30 minutes respectively. Pectin obtained from this study was collected and filtrated by adding 96% ethanol to precipitate the pectin. The best results obtained from extraction process using microwave power of 180 Watt for 30 minutes. This combination of power and time yielded 42.3% pectin with moisture content, ash content, weight equivalent, methoxyl content and galacturonate levels were 8.08%, 5%, 833.33 mg, 6.51% and 58,08%, respectively. The result finding suggested that microwave-assisted extraction method has a great potency on the commercial pectin production.
An Experimental Testbed for a Free-Floating Manipulator
1993-12-01
brushless servo amplifiers are four quadrant , 20 kHz PWM amplifiers that provide economical control of brushless motors rated from 1/3 to 2 Hp shaft Watts...backplanes that came out of the Versa-Module- Europa consortium [Ref. 15]. The VME is a bus that acts as the path and translator of information between
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-08
... of R20 Short Lamps and Unavailability of Substitutes D. Request for Information I. Background The... or has special characteristics not available in substitute lamp types. Specifically, as the lamp has... manufacturers (including designated beam spread and lumen output), there are no substitute products on the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... REQUIREMENTS FOR BICYCLES Regulations § 1512.2 Definitions. For the purposes of this part: (a) Bicycle means...-wheeled vehicle with fully operable pedals and an electric motor of less than 750 watts (1 h.p.), whose... who weighs 170 pounds, is less than 20 mph. (b) Sidewalk bicycle means a bicycle with a seat height of...
CrossTalk: The Journal of Defense Software Engineering. Volume 18, Number 9
2005-09-01
2004. 12. Humphrey , Watts . Introduction to the Personal Software Process SM. Addison- Wesley 1997. 13. Humphrey , Watts . Introduction to the Team...Personal Software ProcessSM (PSPSM)is a software development process orig- inated by Watts Humphrey at the Software Engineering Institute (SEI) in the...meets its commitments and bring a sense of control and predictability into an apparently chaotic project.u References 1. Humphrey , Watts . Coaching
47 CFR 22.593 - Effective radiated power limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 2 2010-10-01 2010-10-01 false Effective radiated power limits. 22.593 Section... power limits. The effective radiated power of fixed stations operating on the channels listed in § 22.591 must not exceed 150 Watts. The equivalent isotropically radiated power of existing fixed microwave...
47 CFR 90.1321 - Power and antenna limits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Power and antenna limits. 90.1321 Section 90... and antenna limits. (a) Base and fixed stations are limited to 25 watts/25 MHz equivalent... receiver. (2) If the transmitter employs an antenna system that emits multiple directional beams but does...
47 CFR 90.1321 - Power and antenna limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Power and antenna limits. 90.1321 Section 90... and antenna limits. (a) Base and fixed stations are limited to 25 watts/25 MHz equivalent... receiver. (2) If the transmitter employs an antenna system that emits multiple directional beams but does...
47 CFR 90.1321 - Power and antenna limits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Power and antenna limits. 90.1321 Section 90... and antenna limits. (a) Base and fixed stations are limited to 25 watts/25 MHz equivalent... receiver. (2) If the transmitter employs an antenna system that emits multiple directional beams but does...
47 CFR 90.1321 - Power and antenna limits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Power and antenna limits. 90.1321 Section 90... and antenna limits. (a) Base and fixed stations are limited to 25 watts/25 MHz equivalent... receiver. (2) If the transmitter employs an antenna system that emits multiple directional beams but does...
47 CFR 90.1321 - Power and antenna limits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Power and antenna limits. 90.1321 Section 90... and antenna limits. (a) Base and fixed stations are limited to 25 watts/25 MHz equivalent... receiver. (2) If the transmitter employs an antenna system that emits multiple directional beams but does...
47 CFR 17.45 - Temporary warning lights.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Temporary warning lights. 17.45 Section 17.45... warning lights. During construction of an antenna structure, for which red obstruction lighting is required, at least two 116- or 125-watt lamps (A21/TS) enclosed in aviation red obstruction light globes...
47 CFR 17.45 - Temporary warning lights.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Temporary warning lights. 17.45 Section 17.45... warning lights. During construction of an antenna structure, for which red obstruction lighting is required, at least two 116- or 125-watt lamps (A21/TS) enclosed in aviation red obstruction light globes...
47 CFR 17.45 - Temporary warning lights.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Temporary warning lights. 17.45 Section 17.45... warning lights. During construction of an antenna structure, for which red obstruction lighting is required, at least two 116- or 125-watt lamps (A21/TS) enclosed in aviation red obstruction light globes...
47 CFR 17.45 - Temporary warning lights.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Temporary warning lights. 17.45 Section 17.45... warning lights. During construction of an antenna structure, for which red obstruction lighting is required, at least two 116- or 125-watt lamps (A21/TS) enclosed in aviation red obstruction light globes...
The Mars Development of a Micro-Isolation Valve
NASA Technical Reports Server (NTRS)
Mueller, Juergen; Vargo, Steven; Forgrave, John; Bame, David; Chakraborty, Indrani; Tang, William
1999-01-01
A feasibility investigation for a newly proposed microfabricated, normally-closed isolation valve was initiated. The micro-isolation valve is silicon based and relies on the principle of melting a silicon plug, opening an otherwise sealed flow passage. This valve may thus serve a similar role as a conventional pyrovalve and is intended for use in micropropulsion systems onboard future microspacecraft, having wet masses of no more than 10-20 kg, as well as in larger scale propulsion systems having only low flow rate requirements, such as ion propulsion or Hall thruster systems. Two key feasibility issues - melting of the plug and pressure handling capability - were addressed. Thermal finite element modeling showed that valves with plugs having widths between 10 and 50 gm have power requirements of only 10 . 30 Watts to open over a duration of 0.5 ms or less. Valve chips featuring 5 0 micron plugs were burst pressure tested and reached maximum pressure values o f 2900 psig (19.7 Mpa).
Specification for strontium-90 500-watt(e) radioisotopic thermoelectric generator
NASA Astrophysics Data System (ADS)
Hammel, T.; Himes, J.; Lieberman, A.; McGrew, J. W.; Owings, D.; Schumann, F.
1983-04-01
A conceptual design for a demonstration 500-watt(e) radioisotopic thermoelectric generator (RTG) was created. The design effort was divided into two tasks, viz., create a design specification for a capsule strenth member that utilizes a standard Strontium 90 fluoride filled WESF inner liner, and create a conceptual design for a 500-watt(e) RTG. The strength member specification was designed to survive an external pressure of 24,500 psi and meet the requirements of special form radioisotope heat sources. Therefore the capsule is if desired, licensed for domestic and international transport. The design for the RTG features a radioisotopic heat source, an array of nine capsules in a tungsten biological shield, four current technology series connected thermoelectric conversion modules, low conductivity thermal insulation, and a passive finned housing radiator for waste heat dissipation. The preliminary RTG specification formulated previous to contract award was met or exceeded.
10 CFR 429.14 - Residential refrigerators, refrigerator-freezers and freezers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... anti-sweat heater control (in which case, manufacturers must also report the values of heater Watts at the ten humidity levels 5%, 15%, through 95% used to calculate the variable anti-sweat heater...
10 CFR 429.14 - Residential refrigerators, refrigerator-freezers and freezers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... anti-sweat heater control (in which case, manufacturers must also report the values of heater Watts at the ten humidity levels 5%, 15%, through 95% used to calculate the variable anti-sweat heater...
10 CFR 429.14 - Residential refrigerators, refrigerator-freezers and freezers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... anti-sweat heater control (in which case, manufacturers must also report the values of heater Watts at the ten humidity levels 5%, 15%, through 95% used to calculate the variable anti-sweat heater...
NASA Astrophysics Data System (ADS)
Agusu, La; Ode Ahmad, La; Anggara, Desna; Alimin; Mitsudo, Seitaro; Fujii, Yutaka; Kikuchi, Hiromitsu
2018-04-01
Reduced graphene oxide has been synthesihzed by one-pot microwave assisted hydrothermal method. Effects of microwave power and irradiation time to its crystal structure and electrical conductivity were investigated. Here, graphene oxide, firstly, were synthesized by modified hummers method and subsequently mixed with Zn as a reducing agent. Then it was transferred to modified domestic microwave oven (800 watts) with glass distiller equipment for completely reduction process. Three different power levels (240, 400, 630 watts) and two cases of irradiation times (20 and 40 minutes) were treated. XRD study shows that irradiation time variation is more effective than the variation of power level. Power level of 270 watts and for 40 minutes microwave irradiation are enough for producing estimated bilayer rGO with graphene interlayer of ~0.4 nm. Bilayer graphene and water molecule (~0.3 nm) may vibrate the same manner and perhaps they are accepting the same temperature. Graphene seems to be re-arranged in unspecified way among the thermal pressure, temperature gradient and/or water surface tension between graphene and water induced by microwave, in order to achieve thermal equilibrium through out the system The electrical conductivity rGO/PVA (60/40 %w) paper are ranging from 15.6 to 43.4 mS/cm.
Magnetic resonance thermometry for monitoring photothermal effects of interstitial laser irradiation
NASA Astrophysics Data System (ADS)
Goddard, Jessica; Jose, Jessnie; Figueroa, Daniel; Le, Kelvin; Liu, Hong; Nordquist, Robert E.; Hode, Tomas; Chen, Wei R.
2012-03-01
Selective photothermal interaction using dye-assisted non-invasive laser irradiation has limitations when treating deeper tumors or when the overlying skin is heavily pigmented. We developed an interstitial laser irradiation method to induce the desired photothermal effects. An 805-nm near-infrared laser with a cylindrical diffuser was used to treat rat mammary tumors by placing the active tip of the fiber inside the target tumors. Three different power settings (1.0 to 1.5 watts) were applied to treat animal tumors with an irradiation duration of 10 minutes. The temperature distributions of the treated tumors were measured by a 7.1-Tesla magnetic resonance imager using proton resonance frequency (PRF) method. Three-dimensional temperature profiles were reconstructed and assessed using PRF. This is the first time a 7.1-Tesla magnetic resonance imager has been used to monitor interstitial laser irradiation via PRF. This study provides a basic understanding of the photothermal interaction needed to control the thermal damage inside tumor using interstitial laser irradiation. It also shows that PRF can be used effectively in monitoring photothermal interaction. Our long-term goal is to develop a PRF-guided laser therapy for cancer treatment.
Feasibility study of a 110 watt per kilogram lightweight solar array system
NASA Technical Reports Server (NTRS)
Shepard, N. F.; Stahle, C. V.; Schneider, A.; Hanson, K. L.
1972-01-01
An investigation of the feasibility of a solar array panel subsystem which will produce 10,000 watts of electrical output at 1 A.U. with an overall beginning-of-life power-to-weight ratio of at least 110 watt/kg is reported. A description of the current baseline configuration which meets these requirements is presented. A parametric analysis of the single boom, two blanket planar solar array system was performed to arrive at the optimum system aspect ratio. A novel concept for the stiffening of a lightweight solar array by canting the solar cell blankets at a small angle to take advantage of the inherent in-plane stiffness to increase the symmetric out-of-plane frequency is introduced along with a preliminary analysis of the stiffening effect. A comparison of welded and soldered solar cell interconnections leads to the conclusion that welding is required on this ultralightweight solar array. The use of a boron/aluminum composite material in a BI-STEM type deployable boom is investigated as a possible advancement in the state-of-the-art.
Fabrication and life testing of thermionic converters
NASA Technical Reports Server (NTRS)
Yang, L.; Bruce, R.
1973-01-01
An unfueled converter containing a chloride-fluoride duplex tungsten emitter of 4.78 eV vacuum work function was tested for 46,647 hours at an emitter temperature of 1973 K and an electrode power output of about 8 watts/sq cm. The test demonstrated the superior and stable performance of the (110) oriented tungsten emitter at high temperatures. Three 90 UC-10 ZrC(C/U = 1.04, tungsten additive = 4 wt %) fueled converters were fabricated and tested at an emitter temperature of 1873 K. Converter containing chloride-arc-cast duplex tungsten cladding showed temperature thermionic performance and slower rate of performance drop than converter containing chloride-fluoride duplex tungsten cladding. This is believed to be due to the superior fuel component diffusion resistance of the arc-cast tungsten substrate used in the fuel cladding. It was shown that a converter containing a carbide fueled chloride-arc-cast duplex tungsten emitter with an initial electrode power output of 6.80 watts/sq cm could still deliver an electrode power output of 6.16 watts/sq cm after 18,632 hours of operation at an emitter temperature of 1873 K.
47 CFR 90.279 - Power limitations applicable to the 421-430 MHz band.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Bands § 90.279 Power limitations applicable to the 421-430 MHz band. (a) Base station authorizations in... Heights (EAH) of Base Stations in the 421-430 MHz Band Effective antenna height (EAH) in meters (feet... maximum transmitter power output that will be authorized for control stations is 20 watts. [52 FR 6157...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haddad, D., E-mail: darine.haddad@nist.gov; Seifert, F.; Williams, C.
A precise instrument, called a watt balance, compares mechanical power measured in terms of the meter, the second, and the kilogram to electrical power measured in terms of the volt and the ohm. A direct link between mechanical action and the Planck constant is established by the practical realization of the electrical units derived from the Josephson and the quantum Hall effects. We describe in this paper the fourth-generation watt balance at the National Institute of Standards and Technology (NIST), and report our initial determination of the Planck constant obtained from data taken in late 2015 and the beginning ofmore » 2016. A comprehensive analysis of the data and the associated uncertainties led to the SI value of the Planck constant, h = 6.626 069 83(22) × 10{sup −34} J s. The relative standard uncertainty associated with this result is 34 × 10{sup −9}.« less
Testing Seam Concepts for Advanced Multilayer Insulation
NASA Technical Reports Server (NTRS)
Chato, D. J.; Johnson, W. L.; Alberts, Samantha J.
2017-01-01
Multilayer insulation (MLI) is considered the state of the art insulation for cryogenic propellant tanks in the space environment. MLI traditionally consists of multiple layers of metalized films separated by low conductivity spacers. In order to better understand some of the details within MLI design and construction, GRC has been investigating the heat loads caused by multiple types of seams. To date testing has been completed with 20 layer and 50 layer blankets. Although a truly seamless blanket is not practical, a blanket lay-up where each individual layer was overlapped and tapped together was used as a baseline for the other seams tests. Other seams concepts tested included: an overlap where the complete blanket was overlapped on top of itself; a butt joint were the blankets were just trimmed and butted up against each other, and a staggered butt joint where the seam in the out layers is offset from the seam in the inner layers. Measured performance is based on a preliminary analysis of rod calibration tests conducted prior to the start of seams testing. Baseline performance for the 50 layer blanket showed a measured heat load of 0.46 Watts with a degradation to about 0.47 Watts in the seamed blankets. Baseline performance for the 20 layer blanket showed a measured heat load of 0.57 Watts. Heat loads for the seamed tests are still begin analyzed. So far analysis work has suggested the need for corrections due to heat loads from both the heater leads and the instrumentation wires. A careful re-examination of the calibration test results with these factors accounted for is also underway. This presentation will discuss the theory of seams in MLI, our test results to date, and the uncertainties in our measurements.
47 CFR 73.811 - LPFM power and antenna height requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 4 2011-10-01 2011-10-01 false LPFM power and antenna height requirements. 73... SERVICES RADIO BROADCAST SERVICES Low Power FM Broadcast Stations (LPFM) § 73.811 LPFM power and antenna... operate with maximum facilities of 100 watts effective radiated power (ERP) at 30 meters antenna height...
47 CFR 73.811 - LPFM power and antenna height requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 4 2012-10-01 2012-10-01 false LPFM power and antenna height requirements. 73... SERVICES RADIO BROADCAST SERVICES Low Power FM Broadcast Stations (LPFM) § 73.811 LPFM power and antenna... operate with maximum facilities of 100 watts effective radiated power (ERP) at 30 meters antenna height...
47 CFR 73.811 - LPFM power and antenna height requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 4 2010-10-01 2010-10-01 false LPFM power and antenna height requirements. 73... SERVICES RADIO BROADCAST SERVICES Low Power FM Broadcast Stations (LPFM) § 73.811 LPFM power and antenna... operate with maximum facilities of 100 watts effective radiated power (ERP) at 30 meters antenna height...
76 FR 17569 - Amateur Service Rules
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-30
... transmit to 10 watts when the station is transmitting a spread spectrum emission. 3. The rules that the.... 97.311 [Amended] 0 2. Section 97.311 is amended by removing paragraph (d). 0 3. Section 97.313 is...) No station may transmit with a transmitter output exceeding 10 W PEP when the station is transmitting...
Superconducting Meissner Effect Bearings for Cryogenic Turbomachines
1991-02-27
mnft turboexpanders used in spaceborne cryocoolers for surveillance sensors. A bearingi breadboard was designed, fabricated, and tested to a... Turboexpander ................................ 8 4.4 Task 7 - Report and Manage ................................... 10 5 SUMMARY AND CONCLUSIONS...fabrication techniques. These studies were performed for a I watt, 10 K cryocooler, where gas bearings for the coldest turboexpander were replaced with
47 CFR 95.135 - Maximum authorized transmitting power.
Code of Federal Regulations, 2011 CFR
2011-10-01
... watts ERP. (d) A fixed station must transmit with no more than 15 watts output power. (e) A small base station must transmit with no more than 5 watts ERP. [48 FR 35237, Aug. 3, 1983, as amended at 53 FR 47717...
2007-03-01
KMO Kaiser-Meyer-Olkin KW Kilo-watts KwH Kilo-watt-hour MAJCOM Major Command MSR Million Solar Roofs MW Mega-watts MWH/yr Mega-watt...direct oblimin rotation and factor restriction for each analysis. A Kaiser-Meyer-Olkin ( KMO ) value of .315 was calculated for the items related to...knowledge, experience, and familiarity, while a KMO value of .389 was calculated for the items related to the two variables of motivation and interest
SMART Power Systems for ANTS Missions
NASA Astrophysics Data System (ADS)
Clark, P. E.; Floyd, S. R.; Curtis, S. A.; Rilee, M. L.
2005-02-01
Autonomous NanoTechnology Swarm (ANTS) Architecture is based on Addressable Reconfigurable Technology (ART) adaptable for the full spectrum of activities in space. ART systems based on currently available electromechanical (EMS) technology could support human crews on the lunar surface within the next 10 to 15 years. Two or more decades from now, NEMS (Super Miniaturized ART or SMART) technology could perform fully autonomous surveys and operations beyond the reach of human crews. Power system requirements would range from 1 kg to generate tens of Watts for near term ART applications, such as a lunar or Mars Lander Amorphous Rover Antenna (LARA), to <0.1 kg to generate hundreds of mWatts for more advanced SMART applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The objectives of the SNAP 7A program were to design, manufacture, test, and deliver a five-watt electric generation system for a U. S. Coast Guard 8 x 26E light buoy. The 10-watt Sr/sup 90/ thermoelectric generator, the d-c-to-d-c converter, batteries and the method of installation in the light buoy are describcd. The SNAP 7A generator was fueled with four capsules containing a total of 40,800 curies of Sr/sup 90/ titanate. After fueling and testing, the SNAP 7A electric generating system was installed in the Coast Guard light buoy at Baltimore, Maryland, on December 15, 1961. Operation of the buoy lampmore » is continuous. (auth)« less
Silicon-controlled-rectifier square-wave inverter with protection against commutation failure
NASA Technical Reports Server (NTRS)
Birchenough, A. G.
1971-01-01
The square-wave SCR inverter that was designed, built, and tested includes a circuit to turn off the inverter in case of commutation failure. The basic power stage is a complementary impulse-commutated parallel inverter consisting of only six components. The 400-watt breadboard was tested while operating at + or - 28 volts, and it had a peak efficiency of 95.5 percent at 60 hertz and 91.7 percent at 400 hertz. The voltage regulation for a fixed input was 3 percent at 60 hertz. An analysis of the operation and design information is included.
Ultrasound enhances retrovirus-mediated gene transfer.
Naka, Toshio; Sakoda, Tsuyoshi; Doi, Takashi; Tsujino, Takeshi; Masuyama, Tohru; Kawashima, Seinosuke; Iwasaki, Tadaaki; Ohyanagi, Mitsumasa
2007-01-01
Viral vector systems are efficient for transfection of foreign genes into many tissues. Especially, retrovirus based vectors integrate the transgene into the genome of the target cells, which can sustain long term expression. However, it has been demonstrated that the transduction efficiency using retrovirus is relatively lower than those of other viruses. Ultrasound was recently reported to increase gene expression using plasmid DNA, with or without, a delivery vehicle. However, there are no reports, which show an ultrasound effect to retrovirus-mediated gene transfer efficiency. Retrovirus-mediated gene transfer systems were used for transfection of 293T cells, bovine aortic endothelial cells (BAECs), rat aortic smooth muscle cells (RASMCs), and rat skeletal muscle myoblasts (L6 cells) with beta-galactosidase (beta-Gal) genes. Transduction efficiency and cell viability assay were performed on 293T cells that were exposed to varying durations (5 to 30 seconds) and power levels (1.0 watts/cm(2) to 4.0 watts/cm(2)) of ultrasound after being transduced by a retrovirus. Effects of ultrasound to the retrovirus itself was evaluated by transduction efficiency of 293T cells. After exposure to varying power levels of ultrasound to a retrovirus for 5 seconds, 293T cells were transduced by a retrovirus, and transduction efficiency was evaluated. Below 1.0 watts/cm(2) and 5 seconds exposure, ultrasound showed increased transduction efficiency and no cytotoxicity to 293T cells transduced by a retrovirus. Also, ultrasound showed no toxicity to the virus itself at the same condition. Exposure of 5 seconds at the power of 1.0 watts/cm(2) of an ultrasound resulted in significant increases in retrovirus-mediated gene expression in all four cell types tested in this experiment. Transduction efficiencies by ultrasound were enhanced 6.6-fold, 4.8-fold, 2.3-fold, and 3.2-fold in 293T cells, BAECs, RASMCs, and L6 cells, respectively. Furthermore, beta-Gal activities were also increased by the retrovirus with ultrasound exposure in these cells. Adjunctive ultrasound exposure was associated with enhanced retrovirus-mediated transgene expression in vitro. Ultrasound associated local gene therapy has potential for not only plasmid-DNA-, but also retrovirus-mediated gene transfer.
Small Stirling dynamic isotope power system for multihundred-watt robotic missions
NASA Technical Reports Server (NTRS)
Bents, David J.
1991-01-01
Free Piston Stirling Engine (FPSE) and linear alternator (LA) technology is combined with radioisotope heat sources to produce a compact dynamic isotope power system (DIPS) suitable for multihundred watt space application which appears competitive with advance radioisotope thermoelectric generators (RTGs). The small Stirling DIPS is scalable to multihundred watt power levels or lower. The FPSE/LA is a high efficiency convertor in sizes ranging from tens of kilowatts down to only a few watts. At multihundred watt unit size, the FPSE can be directly integrated with the General Purpose Heat Source (GPHS) via radiative coupling; the resulting dynamic isotope power system has a size and weight that compares favorably with the advanced modular (Mod) RTG, but requires less than a third the amount of isotope fuel. Thus the FPSE extends the high efficiency advantage of dynamic systems into a power range never previously considered competitive for DIPS. This results in lower fuel cost and reduced radiological hazard per delivered electrical watt.
Small Stirling dynamic isotope power system for multihundred-watt robotic missions
NASA Technical Reports Server (NTRS)
Bents, David J.
1991-01-01
Free piston Stirling Engine (FPSE) and linear alternator (LA) technology is combined with radioisotope heat sources to produce a compact dynamic isotope power system (DIPS) suitable for multihundred watt space application which appears competitive with advanced radioisotope thermoelectric generators (RTGs). The small Stirling DIPS is scalable to multihundred watt power levels or lower. The FPSE/LA is a high efficiency convertor in sizes ranging from tens of kilowatts down to only a few watts. At multihundred watt unit size, the FPSE can be directly integrated with the General Purpose Heat Source (GPHS) via radiative coupling; the resulting dynamic isotope power system has a size and weight that compares favorably with the advanced modular (Mod) RTG, but requires less than a third the amount of isotope fuel. Thus the FPSE extends the high efficiency advantage of dynamic systems into a power range never previously considered competitive for DIPS. This results in lower fuel cost and reduced radiological hazard per delivered electrical watt.
42 CFR 51.11-51.20 - [Reserved
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false [Reserved] 51.11-51.20 Section 51.11-51.20 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS REQUIREMENTS APPLICABLE TO THE PROTECTION AND ADVOCACY FOR INDIVIDUALS WITH MENTAL ILLNESS PROGRAM Basic Requirements §§ 51.11-51...
47 CFR 22.809 - Transmitting power limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transmitting power limits. The transmitting power of ground and airborne mobile transmitters operating on the... Watts, except as provided in § 22.811. (b) Airborne mobile transmitters. The transmitter power output of airborne mobile transmitters must not exceed 25 Watts and must not be less than 4 Watts. ...
75 FR 73136 - Sunshine Act Notice
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-29
.... Place: Commissioners' Conference Room, 11555 Rockville Pike, Rockville, Maryland. Status: Public and.... Affirmation Session (Public Meeting) (Tentative). a. Tennessee Valley Authority (Watts Bar Nuclear Plant, Unit 2), Southern Alliance for Clean Energy's Petition for Interlocutory Review of LBP-10-12 (Denying...
40 CFR 60.3 - Units and abbreviations.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) System International (SI) units of measure: A—ampere g—gram Hz—hertz J—joule K—degree Kelvin kg—kilogram m—meter m3—cubic meter mg—milligram—10 −3 gram mm—millimeter—10 −3 meter Mg—megagram—106 gram mol—mole N—newton ng—nanogram—10 −9 gram nm—nanometer—10 −9 meter Pa—pascal s—second V—volt W—watt Ω—ohm µg...
40 CFR 60.3 - Units and abbreviations.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) System International (SI) units of measure: A—ampere g—gram Hz—hertz J—joule K—degree Kelvin kg—kilogram m—meter m3—cubic meter mg—milligram—10 −3 gram mm—millimeter—10 −3 meter Mg—megagram—106 gram mol—mole N—newton ng—nanogram—10 −9 gram nm—nanometer—10 −9 meter Pa—pascal s—second V—volt W—watt Ω—ohm µg...
40 CFR 60.3 - Units and abbreviations.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) System International (SI) units of measure: A—ampere g—gram Hz—hertz J—joule K—degree Kelvin kg—kilogram m—meter m3—cubic meter mg—milligram—10 −3 gram mm—millimeter—10 −3 meter Mg—megagram—106 gram mol—mole N—newton ng—nanogram—10 −9 gram nm—nanometer—10 −9 meter Pa—pascal s—second V—volt W—watt Ω—ohm µg...
40 CFR 60.3 - Units and abbreviations.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) System International (SI) units of measure: A—ampere g—gram Hz—hertz J—joule K—degree Kelvin kg—kilogram m—meter m3—cubic meter mg—milligram—10 −3 gram mm—millimeter—10 −3 meter Mg—megagram—106 gram mol—mole N—newton ng—nanogram—10 −9 gram nm—nanometer—10 −9 meter Pa—pascal s—second V—volt W—watt Ω—ohm µg...
Construction of a new watt balance with the goal to realize the kilogram in the US
NASA Astrophysics Data System (ADS)
Schlamminger, Stephan; Haddad, Darine; Seifert, Frank; Chao, Leon; Newell, David; Pratt, Jon
2015-04-01
A watt balance is a mechanical device that compares mechanical power to electrical power. Since electrical power is measured using quantum physics by employing the Josephson effect and the Quantum Hall effect, electrical power can be measured as a product of a known factor, two frequencies, and the Planck constant h. Mechanical power is given by mgv , where m is the mass of a weight, g the local acceleration, and v the velocity. Hence, the watt balance provides a link between mass and Planck's constant. Currently several watt balances worldwide are employed to measure h. A redefinition of the international system of units (SI) is currently in discussion and may become reality as early as 2018. In the new SI, the numerical value of the Planck constant will be fixed and the watt balance is a means to realize the unit of mass. Researchers at NIST are preparing for a new SI and we have started in 2011 with plans to design a new watt balance capable of realizing the kilogram with relative uncertainties of a few parts in 108. Construction of the new watt balance has started in 2014. In my talk, I will show some of the latest results achieved with this apparatus.
Code of Federal Regulations, 2011 CFR
2011-01-01
... ballast in accordance with the circuit shown in Figure 2. ER09MR10.006 (iii) Power Line Carrier (PLC) Control Signal. Measure the PLC control signal power (watts), using a wattmeter capable of indicating true... wattmeter must have a frequency response that is at least 10 times higher than the PLC being measured to...
1994-05-01
thermal stresses of 10 million Watts per meter, 1,000 times better than Zerodur *. This property is also important for many thermal management...products UTD has coated to date include: • Optical windows, lenses, and mirrors . Zinc sulfide infrared windows coated with a 2.5 micron-thick...implants 16, 49 microwave plasma-enhanced CVD 2 mirrors , diamond-coated 49 models of diamond growth 10, 25, 33, 34, 39 moderators 10
NASA Technical Reports Server (NTRS)
Miller, W. S.
1974-01-01
The cryogenic refrigerator thermal design calculations establish design approach and basic sizing of the machine's elements. After the basic design is defined, effort concentrates on matching the thermodynamic design with that of the heat transfer devices (heat exchangers and regenerators). Typically, the heat transfer device configurations and volumes are adjusted to improve their heat transfer and pressure drop characteristics. These adjustments imply that changes be made to the active displaced volumes, compensating for the influence of the heat transfer devices on the thermodynamic processes of the working fluid. Then, once the active volumes are changed, the heat transfer devices require adjustment to account for the variations in flows, pressure levels, and heat loads. This iterative process is continued until the thermodynamic cycle parameters match the design of the heat transfer devices. By examing several matched designs, a near-optimum refrigerator is selected.
49 CFR 173.185 - Lithium cells and batteries.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 20 Wh for a lithium ion cell or 100 Wh for a lithium ion battery. After December 31, 2015, each lithium ion battery subject to this provision must be marked with the Watt-hour rating on the outside case... cell and 25 g for a lithium metal battery and 60 Wh for a lithium ion cell or 300 Wh for a lithium ion...
CFD Simulations for Arc-Jet Panel Testing Capability Development Using Semi-Elliptical Nozzles
NASA Technical Reports Server (NTRS)
Gokcen, Tahir; Balboni, John A.; Hartman, G. Joseph
2016-01-01
This paper reports computational simulations in support of arc-jet panel testing capability development using semi-elliptical nozzles in a high enthalpy arc-jet facility at NASA Ames Research Center. Two different semi-elliptical nozzle configurations are proposed for testing panel test articles. Computational fluid dynamics simulations are performed to provide estimates of achievable panel surface conditions and useful test area for each configuration. The present analysis comprises three-dimensional simulations of the nonequilibrium flowfields in the semi-elliptical nozzles, test box and flowfield over the panel test articles. Computations show that useful test areas for the proposed two nozzle options are 20.32 centimeters by 20.32 centimeters (8 inches by 8 inches) and 43.18 centimeters by 43.18 centimeters (17 inches by 17 inches). Estimated values of the maximum cold-wall heat flux and surface pressure are 155 watts per centimeters squared and 39 kilopascals for the smaller panel test option, and 44 watts per centimeters squared and 7 kilopascals for the larger panel test option. Other important properties of the predicted flowfields are presented, and factors that limit the useful test area in the semi-free jet test configuration are discussed.
Okumura, Yasuo; Johnson, Susan B; Bunch, T Jared; Henz, Benhur D; O'Brien, Christine J; Packer, Douglas L
2008-06-01
While catheter tip/tissue contact has been shown to be an important determinant of ablative lesions in in vitro studies, the impact of contact on the outcomes of mapping and ablation in the intact heart has not been evaluated. Twelve dogs underwent atrial ablation guided by the Senesitrade mark robotic catheter remote control system. After intracardiac ultrasound (ICE) validation of contact force measured by an in-line mechanical sensor, the relationship between contact force and individual lesion formation was established during irrigated-tipped ablation (flow 17 mL/sec) at 15 watts for 30 seconds. Minimal contact by ICE correlated with force of 4.7 +/- 5.8 grams, consistent contact 9.9 +/- 8.6 grams and tissue tenting produced 25.0 +/- 14.0 grams. Conversely, catheter tip/tissue contact by ICE was predicted by contact force. A contact force of 10-20 and > or =20 grams generated full-thickness, larger volume ablative lesions than that created with <10 grams (98 +/- 69 and 89 +/- 70 mm(3) vs 40 +/- 42 mm(3), P < 0.05). Moderate (10 grams) and marked contact (15-20 grams) application produced 1.5 X greater electroanatomic map volumes that were seen with minimal contact (5 grams) (26 +/- 3 cm(3) vs 33 +/- 6, 39 +/- 3 cm(3), P < 0.05). The electroanatomic map/CT merge process was also more distorted when mapping was generated at moderate to marked contact force. This study shows that mapping and ablation using a robotic sheath guidance system are critically dependent on generated force. These findings suggest that ablative lesion size is optimized by the application of 10-20 grams of contact force, although mapping requires lower-force application to avoid image distortions.
47 CFR 101.1333 - Interference protection criteria.
Code of Federal Regulations, 2010 CFR
2010-10-01
... is in watts, D is in meters, and the power is relative to an isotropic radiator. The technical... for master stations operating at a maximum power shall not exceed 150 meters. Above 150 meters, the... Reduction Table Antenna height above average terrain (meters) EIRP Watts dBW ERP Watts dBW Above 305 200 23...
ERIC Educational Resources Information Center
Harrer, Benedikt W.; Flood, Virginia J.; Wittmann, Michael C.
2013-01-01
For over 30 years, researchers have investigated students' ideas about energy with the intent of reforming instructional practice. In this pursuit, Watts contributed an influential study with his 1983 paper "Some alternative views of energy" ["Phys. Educ." 18, 213 (1983)]. Watts' "alternative frameworks"…
The Cabinet Member as a Representative of the President: The Case of James Watt.
ERIC Educational Resources Information Center
Renz, Mary Ann
1987-01-01
Compares the environmental rhetoric of former U.S. Interior Secretary James Watt and U.S. President Ronald Reagan, explaining that Watt's political value outweighed his political liability. Notes that cabinet members extend a President's influence by reaching issue-specific audiences while maintaining philosophical consistency, and serve as…
78 FR 35989 - Tennessee Valley Authority; Watts Bar Nuclear Plant, Unit 2
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-14
... Bar Nuclear Plant, Unit 2 AGENCY: Nuclear Regulatory Commission. ACTION: Final environmental statement... Operation of Watts Bar Nuclear Plant (WBN), Unit 2'' (SFES). ADDRESSES: Please refer to Docket ID NRC-2008... option of issuing the operating license for Watts Bar Nuclear Plant, Unit 2. This recommendation is based...
The Anti-RFI Design of Intelligent Electric Energy Meters with UHF RFID
NASA Astrophysics Data System (ADS)
Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng
2018-03-01
In order to solve the existing artificial meter reading watt-hour meter industry is still slow and inventory of common problems, using the uhf radio frequency identification (RFID) technology and intelligent watt-hour meter depth fusion, which has a one-time read multiple tags, identification distance, high transmission rate, high reliability, etc, while retaining the original asset management functions, in order to ensure the uhf RFID and minimum impact on the operation of the intelligent watt-hour meter, proposed to improve the stability of the electric meter system while working at the same time, this paper designs the uhf RFID intelligent watt-hour meter radio frequency interference resistance, put forward to improve intelligent watt-hour meter electromagnetic compatibility design train of thought, and introduced its power and the hardware circuit design of printed circuit board, etc.
Self-contained eye-safe laser radar using an erbium-doped fiber laser
NASA Astrophysics Data System (ADS)
Driscoll, Thomas A.; Radecki, Dan J.; Tindal, Nan E.; Corriveau, John P.; Denman, Richard
2003-07-01
An Eye-safe Laser Radar has been developed under White Sands Missile Range sponsorship. The SEAL system, the Self-contained Eyesafe Autonomous Laser system, is designed to measure target position within a 0.5 meter box. Targets are augmented with Scotchlite for ranging out to 6 km and augmented with a retroreflector for targets out to 20 km. The data latency is less than 1.5 ms, and the position update rate is 1 kHz. The system is air-cooled, contained in a single 200-lb, 6-cubic-foot box, and uses less than 600 watts of prime power. The angle-angle-range data will be used to measure target dynamics and to control a tracking mount. The optical system is built around a diode-pumped, erbium-doped fiber laser rated at 1.5 watts average power at 10 kHz repetition rate with 25 nsec pulse duration. An 8 inch-diameter, F/2.84 telescope is relayed to a quadrant detector at F/0.85 giving a 5 mrad field of view. Two detectors have been evaluated, a Germanium PIN diode and an Intevac TE-IPD. The receiver electronics uses a DSP network of 6 SHARC processors to implement ranging and angle error algorithms along with an Optical AGC, including beam divergence/FOV control loops.Laboratory measurements of the laser characteristics, and system range and angle accuracies will be compared to simulations. Field measurements against actual targets will be presented.
I-V Curves from Photovoltaic Modules Deployed in Tucson
NASA Astrophysics Data System (ADS)
Kopp, Emily; Brooks, Adria; Lonij, Vincent; Cronin, Alex
2011-10-01
More than 30 Mega Watts of photo-voltaic (PV) modules are connected to the electric power grid in Tucson, AZ. However, predictions of PV system electrical yields are uncertain, in part because PV modules degrade at various rates (observed typically in the range 0% to 3 %/yr). We present I-V curves (PV output current as a function of PV output voltage) as a means to study PV module efficiency, de-ratings, and degradation. A student-made I-V curve tracer for 100-Watt modules will be described. We present I-V curves for several different PV technologies operated at an outdoor test yard, and we compare new modules to modules that have been operated in the field for 10 years.
High-power diffusing-tip fibers for interstitial photocoagulation
NASA Astrophysics Data System (ADS)
Sinofsky, Edward L.; Farr, Norman; Baxter, Lincoln; Weiler, William
1997-05-01
A line of optical fiber based diffusing tips has been designed, developed, and tested that are capable of distributing tens of watts of cw laser power over lengths ranging from two millimeters to over 10 cm. The result is a flexible non-stick diffuser capable of coagulating large volumes of tissue in reasonably short exposures of 3 - 5 minutes. Sub-millimeter diameter devices have a distinct effect on reducing the force needed to insert the applicator interstitially into tissue. Utilizing our design approach, we have produced diffusers based on 200 micrometer core fiber that has delivered over 35 watts of Nd:YAG energy over diffusion lengths as short as 4 mm. These applicators are being tested for applications in oncology, cardiology, electrophysiology, urology and gynecology.
40 CFR 60.3 - Units and abbreviations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... m—meter m3—cubic meter mg—milligram—10 −3 gram mm—millimeter—10 −3 meter Mg—megagram—106 gram mol—mole N—newton ng—nanogram—10 −9 gram nm—nanometer—10 −9 meter Pa—pascal s—second V—volt W—watt Ω—ohm µg...—calorie cfm—cubic feet per minute cu ft—cubic feet dcf—dry cubic feet dcm—dry cubic meter dscf—dry cubic...
Exploring high power, extreme wavelength operating potential of rare-earth-doped silica fiber
NASA Astrophysics Data System (ADS)
Zhou, Pu; Li, Ruixian; Xiao, Hu; Huang, Long; Zhang, Hanwei; Leng, Jinyong; Chen, Zilun; Xu, Jiangmin; Wu, Jian; Wang, Xiong
2017-08-01
Ytterbium-doped fiber laser (YDFL) and Thulium doped fiber laser (TDFL) have been two kinds of the most widely studied fiber laser in recent years. Although both silica-based Ytterbium-doped fiber and Thulium doped fiber have wide emission spectrum band (more than 200 nm and 400 nm, respectively), the operation spectrum region of previously demonstrated high power YDFL and TDFL fall into 1060-1100 nm and 1900-2050nm. Power scaling of YDFL and TDFL operates at short-wavelength or long-wavelength band, especially for extreme wavelength operation, although is highly required in a large variety of application fields, is quite challenging due to small net gain and strong amplified spontaneous emission (ASE). In this paper, we will present study on extreme wavelength operation of high power YDFL and TDFL in our group. Comprehensive mathematical models are built to investigate the feasibility of high power operation and propose effective technical methods to achieve high power operation. We have achieved (1) Diodepumped 1150nm long wavelength YDFL with 120-watt level output power (2) Diode-pumped 1178nm long wavelength YDFL operates at high temperature with 30-watt level output power (3) Random laser pumped 2153nm long wavelength TDFL with 20-watt level output power (4) Diode-pumped 1018nm short wavelength YDFL with a record 2 kilowatt output power is achieved by using home-made fiber combiner.
A Survey of Principles Instructors: Why Lecture Prevails
ERIC Educational Resources Information Center
Goffe, William L.; Kauper, David
2014-01-01
For many years, surveys have shown that lecture is the dominant method for teaching principles of economics (Watts and Schaur 2011; Watts and Becker 2008; Becker and Watts 1996, 2001a, b). The authors confirm this and augment it by asking why principles instructors teach the way they do. The respondents, 340 principles instructors at the 2012…
47 CFR 2.1091 - Radiofrequency radiation exposure evaluation: mobile devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... their effective radiated power (ERP) is 1.5 watts or more, or if they operate at frequencies above 1.5 GHz and their ERP is 3 watts or more. Unlicensed personal communications service devices, unlicensed... exposure prior to equipment authorization or use if their ERP is 3 watts or more or if they meet the...
Changing lamp type and position to improve lighting quality
NASA Astrophysics Data System (ADS)
Anizar; Syahputri, K.; Sari, RM; Rizkya, I.; Hardianti, DA
2018-03-01
This study investigates the lighting quality on the production floor in a cigarette paper industry by measuring illumination level and luminance. Cigarette paper inspection is performed manually by operators, and the criteria of defects are the cigarette paper has a hole, is rough and dirty. Operators complain that the room is pretty dark, which makes them unable to see clearly the cigarette paper defect. The government of Indonesia Health Ministerial Decree No 1405 The Year 2002 states that illumination level for continuous manual labor is 200 lux. Illumination level is measured for four days at 08.00, 10.00, 12.30, and 14.00 o’clock with 4 in 1 environmental meter. From the measurement result, it is found that using 7 LED lamps of 60 Watts can produce average illumination level of 70 lux. Low illuminance is caused by illumination level that does not meet the need 0f 569.759 lumen. Alternatives that can be used to increase lumen number are changing lamp type and position. One of the possibilities is using 24 LED of 138 Watts set 5.7 meters apart from one another can meet this demand. Another is using 5 LED of 150 Watts installed above the field of work.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-25
... implementation date for certain new requirements of 10 CFR Part 73, ``Physical protection of plants and materials... March 31, 2010, for several new requirements of 10 CFR Part 73. Specifically, WBN, Units 1 and 2 would... Part 73. The proposed action, an extension of the schedule for completion of certain actions required...
40 CFR 51.352 - Basic I/M performance standard.
Code of Federal Regulations, 2010 CFR
2010-07-01
...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...
40 CFR 51.352 - Basic I/M performance standard.
Code of Federal Regulations, 2014 CFR
2014-07-01
...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...
40 CFR 51.352 - Basic I/M performance standard.
Code of Federal Regulations, 2011 CFR
2011-07-01
...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...
40 CFR 51.352 - Basic I/M performance standard.
Code of Federal Regulations, 2012 CFR
2012-07-01
...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...
40 CFR 51.352 - Basic I/M performance standard.
Code of Federal Regulations, 2013 CFR
2013-07-01
...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...
Solutions-based climate change education for K-Gray: Renewable energy and energy efficiency
NASA Astrophysics Data System (ADS)
Petrone, C.
2017-12-01
Through the National Science Foundation-funded MADE CLEAR (www.madeclear.org) climate change education project's Informal Climate Change Education (ICCE) Community, funds were received to collaboratively train teachers, informal educators, students, and university docents in climate change basics and solutions, specifically renewable energy and energy efficiency. In all, 10 docents, 50 classroom teachers, over 600 K-16 students, and several hundred science-interested citizens participated in programs and workshops lasting between one and seven hours. Using commercially available kits and other DIY projects, program participants used science content and engineering to develop models of wind turbines, wind mills, solar cells, solar cookers, solar stills, and wind-powered cars. Using thermal imaging cameras, Kill-a-Watt meters, "Carbon Food Print" kit, "Energy Matters" kit, and other tools, program participants learned about energy efficiency as not only a global climate change mitigation strategy, but also a way to save money. ICCE Community members and external partners, such as local electric cooperative personnel, university researchers, and state-sponsored energy efficiency program personnel, provided content presentations, discussions, and hands-on activities to program participants.
Recent progress on the National Ignition Facility advanced radiographic capability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wegner, P.; Bowers, M.; Chen, H.
2016-01-08
The National Ignition Facility (NIF) is a megajoule (million-joule)-class laser and experimental facility built for Stockpile Stewardship and High Energy Density (HED) science research [1]. Up to several times a day, 192 laser pulses from NIF's 192 laser beamlines converge on a millimeter-scale target located at the center of the facility's 10-meter diameter target chamber. The carefully synchronized pulses, typically a few nanoseconds (billionths of a second) in duration and co-times to better than 20 picoseconds (trillionths of a second), a deliver a combined energy of up to 1.8 megajoules and a peak power of 500 terawatts (trillion watts). Furthermore,more » this drives temperatures inside the target to tens of millions of degrees and pressures to many billion times greater than Earth's atmosphere.« less
Millimeter-wave generation with spiraling electron beams
NASA Technical Reports Server (NTRS)
Kulke, B.
1971-01-01
The feasibility of using the interaction between a thin, solid, spiraling electron beam of 10 to 20 kV energy and a microwave cavity to generate watts of CW millimeter-wave power was investigated. Experimental results are given for several prototype devices operating at 9.4 GHz and at 94 GHz. Power outputs of 5 W, and electronic efficiencies near 3%, were obtained at X band, and moderate gain was obtained at 94 GHz. The small-signal theory gives a good fit to the X-band data, and the device behavior at 94 GHz is as expected from the given beam characteristics. The performance is limited chiefly by the velocity spread in the spiraling electron beam, and once this can be brought under control, high-power generation of millimeter waves appears quite feasible with this type of device.
47 CFR 95.135 - Maximum authorized transmitting power.
Code of Federal Regulations, 2010 CFR
2010-10-01
... transmitting power. (a) No station may transmit with more than 50 watts output power. (b) [Reserved] (c) A small control station at a point north of Line A or east of Line C must transmit with no more than 5 watts ERP. (d) A fixed station must transmit with no more than 15 watts output power. (e) A small base...
47 CFR 90.542 - Broadband transmitting power limits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the 763-768 MHz band with an emission bandwidth of 1 MHz or less must not exceed an ERP of 1000 watts... if power levels are reduced below 1000 watts ERP in accordance with Table 1 of this section. (2... ERP of 2000 watts and an antenna height of 305 m HAAT, except that antenna heights greater than 305 m...
The Watts Premier Ultra 5 system was tested for removal of bacteria and viruses at NSF International's Laboratory. Watts Premier submitted ten units, which were split into two groups of five. One group received 25 days of conditioning prior to challenge testing, while the secon...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-30
... accordance with the NRC E-Filing rule. See 10 CFR 2.302 et seq. Issued at Rockville, Maryland this 16th day of November 2012. E. Roy Hawkens, Chief Administrative Judge, Atomic Safety and Licensing Board Panel...
47 CFR 74.534 - Power limitations.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., transmitter output power shall not exceed 10 watts. (b) In no event shall the average equivalent isotropically..., order a change in the equivalent isotropically radiated power of this station. Frequency band (MHz..., subject to periodic renewal. (c) The EIRP of transmitters that use Automatic Transmitter Power Control...
47 CFR 74.534 - Power limitations.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., transmitter output power shall not exceed 10 watts. (b) In no event shall the average equivalent isotropically..., order a change in the equivalent isotropically radiated power of this station. Frequency band (MHz..., subject to periodic renewal. (c) The EIRP of transmitters that use Automatic Transmitter Power Control...
Solar maximum: Solar array degradation
NASA Technical Reports Server (NTRS)
Miller, T.
1985-01-01
The 5-year in-orbit power degradation of the silicon solar array aboard the Solar Maximum Satellite was evaluated. This was the first spacecraft to use Teflon R FEP as a coverglass adhesive, thus avoiding the necessity of an ultraviolet filter. The peak power tracking mode of the power regulator unit was employed to ensure consistent maximum power comparisons. Telemetry was normalized to account for the effects of illumination intensity, charged particle irradiation dosage, and solar array temperature. Reference conditions of 1.0 solar constant at air mass zero and 301 K (28 C) were used as a basis for normalization. Beginning-of-life array power was 2230 watts. Currently, the array output is 1830 watts. This corresponds to a 16 percent loss in array performance over 5 years. Comparison of Solar Maximum Telemetry and predicted power levels indicate that array output is 2 percent less than predictions based on an annual 1.0 MeV equivalent election fluence of 2.34 x ten to the 13th power square centimeters space environment.
Theory and applications for optimization of every part of a photovoltaic system
NASA Technical Reports Server (NTRS)
Redfield, D.
1978-01-01
A general method is presented for quantitatively optimizing the design of every part and fabrication step of an entire photovoltaic system, based on the criterion of minimum cost/Watt for the system output power. It is shown that no element or process step can be optimized properly by considering only its own cost and performance. Moreover, a fractional performance loss at any fabrication step within the cell or array produces the same fractional increase in the cost/Watt of the entire array, but not of the full system. One general equation is found to be capable of optimizing all parts of a system, although the cell and array steps are basically different from the power-handling elements. Applications of this analysis are given to show (1) when Si wafers should be cut to increase their packing fraction; and (2) what the optimum dimensions for solar cell metallizations are. The optimum shadow fraction of the fine grid is shown to be independent of metal cost and resistivity as well as cell size. The optimum thicknesses of both the fine grid and the bus bar are substantially greater than the values in general use, and the total array cost has a major effect on these values. By analogy, this analysis is adaptable to other solar energy systems.
Analysis of AC and DC Lighting Systems with 150-Watt Peak Solar Panel in Denpasar Based on NASA Data
NASA Astrophysics Data System (ADS)
Narottama, A. A. N. M.; Amerta Yasa, K.; Suwardana, I. W.; Sapteka, A. A. N. G.; Priambodo, P. S.
2018-01-01
Solar energy on the Earth’s surface has different magnitudes on every longitude and latitude. National Aeronautics and Space Administration (NASA) provides surface meteorology and solar energy database which can be accessed openly online. This database delivers information about Monthly Averaged Insolation Incident On A Horizontal Surface, Monthly Averaged Insolation Incident On A Horizontal Surface At Indicated GMT Times and also data about Equivalent Number Of No-Sun Or Black Days for any latitude and longitude. Therefore, we investigate the lighting systems with 150-Watt peak solar panel in Denpasar City, the capital province of Bali. Based on NASA data, we analyse the received wattage by a unit of 150-Watt peak solar panel in Denpasar City and the sustainability of 150-Watt peak solar panel to supply energy for 432-Watt hour/day AC and 360-Watt hour/day DC lighting systems using 1.2 kWh battery. The result shows that the maximum received wattage by a unit of 150-Watt peak solar panel is 0.76 kW/day in October. We concluded that the 1.2 kWh installed battery has higher capacity than the battery capacity needed in March, the month with highest no-sun days, for both AC and DC lighting systems. We calculate that the installed battery can be used to store the sustainable energy from sun needed by AC and DC lighting system for about 2.78 days and 3.51 days, consecutively.
Santana, Hugo A P; Moreira, Sérgio R; Neto, Willson B; Silva, Carla B; Sales, Marcelo M; Oliveira, Vanessa N; Asano, Ricardo Y; Espíndola, Foued S; Nóbrega, Otávio T; Campbell, Carmen S G; Simões, Herbert G
2011-12-02
The absence of the I allele of the angiotensin converting enzyme (ACE) gene has been associated with higher levels of circulating ACE, lower nitric oxide (NO) release and hypertension. The purposes of this study were to analyze the post-exercise salivary nitrite (NO2-) and blood pressure (BP) responses to different exercise intensities in elderly women divided according to their ACE genotype. Participants (n = 30; II/ID = 20 and DD = 10) underwent three experimental sessions: incremental test - IT (15 watts workload increase/3 min) until exhaustion; 20 min exercise 90% anaerobic threshold (90% AT); and 20 min control session without exercise. Volunteers had their BP and NO2- measured before and after experimental sessions. Despite both intensities showed protective effect on preventing the increase of BP during post-exercise recovery compared to control, post-exercise hypotension and increased NO2- release was observed only for carriers of the I allele (p < 0.05). Genotypes of the ACE gene may exert a role in post-exercise NO release and BP response.
Three Dimensional High-Resolution Reconstruction of the Ionosphere Over the Very Large Array
2010-12-15
Watts Progress Report, Dec 10; 1 Final Report: Three Dimensional High-Resolution Reconstruction of the Ionosphere over the Very Large Array...proposed research is reconstruct the three-dimensional regional electron density profile of Earth’s ionosphere with spatial resolution of better than 10 km...10x better sensitivity to total electron content (TEC, or chord integrated density) in the ionosphere that does GPS. The proposal funds the
Gaskill, S E; Walker, A J; Serfass, R A; Bouchard, C; Gagnon, J; Rao, D C; Skinner, J S; Wilmore, J H; Leon, A S
2001-11-01
The purpose of this study was to evaluate the effect of exercise training intensity relative to the ventilatory threshold (VT) on changes in work (watts) and VO2 at the ventilatory threshold and at maximal exercise in previously sedentary participants in the HERITAGE Family Study. We hypothesized that those who exercised below their VT would improve less in VO2 at the ventilatory threshold (VO2vt) and VO2max than those who trained at an intensity greater than their VT. Supervised cycle ergometer training was performed at the 4 participating clinical centers, 3 times a week for 20 weeks. Exercise training progressed from the HR corresponding to 55% VO2max for 30 minutes to the HR associated with 75% VO2max for 50 minutes for the final 6 weeks. VT was determined at baseline and after exercise training using standardized methods. 432 sedentary white and black men (n = 224) and women (n = 208), aged 17 to 65 years, were retrospectively divided into groups based on whether exercise training was initiated below, at, or above VT. 1) Training intensity (relative to VT) accounting for about 26% of the improvement in VO2vt (R2 = 0.26, p < 0.0001). 2) The absolute intensity of training in watts (W) accounted for approximately 56% of the training effect at VT (R2 = 0.56, p < 0.0001) with post-training watts at VT (VT(watts)) being not significantly different than W during training (p > 0.70). 3) Training intensity (relative to VT) had no effect on DeltaVO2max. These data clearly show that as a result of aerobic training both the VO2 and W associated with VT respond and become similar to the absolute intensity of sustained (3 x /week for 50 min) aerobic exercise training. Higher intensities of exercise, relative to VT, result in larger gains in VO2vt but not in VO2max.
47 CFR 74.534 - Power limitations.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., transmitter output power shall not exceed 10 watts. (b) In no event shall the average equivalent isotropically..., order a change in the equivalent isotropically radiated power of this station. Frequency band (MHz... (ATPC) shall not exceed the EIRP specified on the station authorization. The EIRP of non-ATPC...
47 CFR 74.534 - Power limitations.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., transmitter output power shall not exceed 10 watts. (b) In no event shall the average equivalent isotropically..., order a change in the equivalent isotropically radiated power of this station. Frequency band (MHz... (ATPC) shall not exceed the EIRP specified on the station authorization. The EIRP of non-ATPC...
47 CFR 74.534 - Power limitations.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., transmitter output power shall not exceed 10 watts. (b) In no event shall the average equivalent isotropically..., order a change in the equivalent isotropically radiated power of this station. Frequency band (MHz... (ATPC) shall not exceed the EIRP specified on the station authorization. The EIRP of non-ATPC...
Solar Pumped Solid State Lasers for Space Solar Power: Experimental Path
NASA Technical Reports Server (NTRS)
Fork, Richard L.; Carrington, Connie K.; Walker, Wesley W.; Cole, Spencer T.; Green, Jason J. A.; Laycock, Rustin L.
2003-01-01
We outline an experimentally based strategy designed to lead to solar pumped solid state laser oscillators useful for space solar power. Our method involves solar pumping a novel solid state gain element specifically designed to provide efficient conversion of sunlight in space to coherent laser light. Kilowatt and higher average power is sought from each gain element. Multiple such modular gain elements can be used to accumulate total average power of interest for power beaming in space, e.g., 100 kilowatts and more. Where desirable the high average power can also be produced as a train of pulses having high peak power (e.g., greater than 10(exp 10 watts). The modular nature of the basic gain element supports an experimental strategy in which the core technology can be validated by experiments on a single gain element. We propose to do this experimental validation both in terrestrial locations and also on a smaller scale in space. We describe a terrestrial experiment that includes diagnostics and the option of locating the laser beam path in vacuum environment. We describe a space based experiment designed to be compatible with the Japanese Experimental Module (JEM) on the International Space Station (ISS). We anticipate the gain elements will be based on low temperature (approx. 100 degrees Kelvin) operation of high thermal conductivity (k approx. 100 W/cm-K) diamond and sapphire (k approx. 4 W/cm-K). The basic gain element will be formed by sequences of thin alternating layers of diamond and Ti:sapphire with special attention given to the material interfaces. We anticipate this strategy will lead to a particularly simple, robust, and easily maintained low mass modelocked multi-element laser oscillator useful for space solar power.
Jäger, Ralf; Shields, Kevin A.; Lowery, Ryan P.; De Souza, Eduardo O.; Partl, Jeremy M.; Hollmer, Chase; Purpura, Martin
2016-01-01
Objective. Probiotics have been reported to support healthy digestive and immune function, aid in protein absorption, and decrease inflammation. Further, a trend to increase vertical jump power has been observed following co-administration of protein and probiotics in resistance-trained subjects. However, to date the potential beneficial effect of probiotics on recovery from high intensity resistance exercise have yet to be explored. Therefore, this study examined the effect of co-administration of protein and probiotics on muscle damage, recovery and performance following a damaging exercise bout. Design. Twenty nine (n = 29) recreationally-trained males (mean ± SD; 21.5 ± 2.8 years; 89.7 ± 28.2 kg; 177.4 ± 8.0 cm) were assigned to consume either 20 g of casein (PRO) or 20 g of casein plus probiotic (1 billion CFU Bacillus coagulans GBI-30, 6086, PROBC) in a crossover, diet-controlled design. After two weeks of supplementation, perceptional measures, athletic performance, and muscle damage were analyzed following a damaging exercise bout. Results. The damaging exercise bout significantly increased muscle soreness, and reduced perceived recovery; however, PROBC significantly increased recovery at 24 and 72 h, and decreased soreness at 72 h post exercise in comparison to PRO. Perceptual measures were confirmed by increases in CK (PRO: +266.8%, p = 0.0002; PROBC: +137.7%, p = 0.01), with PROBC showing a trend towards reduced muscle damage (p = 0.08). The muscle-damaging exercise resulted in significantly increased muscle swelling and Blood Urea Nitrogen levels in both conditions with no difference between groups. The strenuous exercise significantly reduced athletic performance in PRO (Wingate Peak Power; PRO: (−39.8 watts, −5.3%, p = 0.03)), whereas PROBC maintained performance (+10.1 watts, +1.7%). Conclusions. The results provide evidence that probiotic supplementation in combination with protein tended to reduce indices of muscle damage, improves recovery, and maintains physical performance subsequent to damaging exercise. PMID:27547577
On-Orbit and Ground Performance of the PGBA Plant Growth Facility
NASA Technical Reports Server (NTRS)
Hoehn, A.; Chamberlain, D. J.; Forsyth, S. W.; Hanna, D. S.; Scovazzo, P.; Stodieck, L. S.; Heyenga, G.; Kliss, Mark
1997-01-01
PGBA, a plant growth facility developed for commercial space biotechnology research, successfully grew a total of 30 plants (6 species) for 10 days on board the Space Shuttle Endeavour (STS-77) and is scheduled for reflight on board MSL-1 (STS-83) for a 16 day flight. The PGBA life support systems provide atmospheric, thermal, and humidity control as well as lighting and nutrient supply in a 23.6 liter chamber. Atmosphere treatment includes ethylene and other hydrocarbon removal, CO2 replenishment, and O2 control. The normally closed system uses controlled CO2 replenishment from the crew cabin as required by the plants. Temperature is controlled (1 C) at user-specified setpoints between 20-32 C, using water-filled coolant loops, solid state Peltier thermoelectric devices, and liquid heat exchangers. The thermoelectric cooling systems were optimized for low power consumption and high cooling efficiencies. Relative humidity is maintained between 60-100% using a cooled porous metal plate to remove water vapor from the air stream without cooling the bulk air below the dew point. The lighting system utilizes three compact fluorescent bi-axial lights with variable lighting control and light intensity (PAR) between 220 and 330 micromol/sq m/s at a distance of 20 cm in spaceflight configuration (on orbit power limited to 230 Watt for entire payload). A ground, up to 550 micromol/sq m/s light intensity can be achieved with 330 Watt payload power consumption. Plant water and nutrient support is sustained via the 'Nutrient Pack' system including the passive or active 'Water Replenishable Nutrient Pack.' The root matrix material (soil or Agar) and nutrient formulation of each pack is prepared according to plant species and experimental requirements. These systems were designed by NASA Ames personnel. Data acquisition and control systems provide 32 channels of environmental data as well as digitized or analog video signals for downlink.
Code of Federal Regulations, 2010 CFR
2010-01-01
... fluorescent lamp is designed to operate. 1.14PLC control signal means a power line carrier (PLC) signal that....3Power Line Carrier (PLC) Control Signal. Measure the PLC control signal power (watts), using a wattmeter... have a frequency response that is at least 10 times higher than the PLC being measured in order to...
Code of Federal Regulations, 2011 CFR
2011-01-01
... fluorescent lamp is designed to operate. 1.14PLC control signal means a power line carrier (PLC) signal that....3Power Line Carrier (PLC) Control Signal. Measure the PLC control signal power (watts), using a wattmeter... have a frequency response that is at least 10 times higher than the PLC being measured in order to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-02
... under 10 CFR 2.315(c), must be filed in accordance with the NRC E-Filing rule (72 FR 49139, August 28, 2007). The E-Filing process requires participants to submit and serve all adjudicatory documents over... below. To comply with the procedural requirements of E-Filing, at least ten 10 days prior to the filing...
1989-09-01
003 .0008 -.009 .10 .20 -.015 . 624 -. 006 -. 007 .0009 -. 017 .20 .30 -.010 .653 -.060 -. 015 .0014 -.028 .30 .40 -.015 .691 -. 143 -.017 .0024 -.041...084 -. 014 .0019 -. 031 .30 .40 -. 001 .762 -. 175 .003 .8831 -.844 .40 85 -. 48 -. 001 .781 -. 160 -. 011 -.0001 .043 -.40 -. 30 .002 .679 -. 133...044 -. 016 .0012 -. 010 -. 30 -. 20 .010 .163 .043 -. 017 .0012 -. 005 -. 20 -. 10 .009 .159 .043 -.014 .0010 -.002 -. 10 -.05 .007 . 160 .044 -.012
A small, single stage orifice pulse tube cryocooler demonstration
NASA Technical Reports Server (NTRS)
Hendricks, John B.
1990-01-01
This final report summarizes and presents the analytical and experimental progress in the present effort. The principal objective of this effort was the demonstration of a 0.25 Watt, 80 Kelvin orifice pulse tube refrigerator. The experimental apparatus is described. The design of a partially optimized pulse tube refrigerator is included. The refrigerator demonstrates an ultimate temperature of 77 K, has a projected cooling power of 0.18 Watts at 80 K, and has a measured cooling power of 1 Watt at 97 K, with an electrical efficiency of 250 Watts/Watt, much better than previous pulse tube refrigerators. A model of the pulse tube refrigerator that provides estimates of pressure ratio and mass flow within the pulse tube refrigerator, based on component physical characteristics is included. A model of a pulse tube operation based on generalized analysis which is adequate to support local optimization of existing designs is included. A model of regenerator performance based on an analogy to counterflow heat exchangers is included.
O'Reilly, D St J; Carter, R; Bell, E; Hinnie, J; Galloway, P J
2003-05-01
The cardio-pulmonary and biochemical changes observed in a case of McArdle's disease, exercising with increasing work rates to exhaustion in the "second-wind" phase of exercise are reported for the first time. A work rate of 275-325 watts was achieved. Venous blood lactate remained unchanged throughout. The plasma ammonium level reached a plateau of approximately 400 mmol/l at 100 watts. At a work rate of 150-175 watts the ratio of O2 consumption to CO2 production increased, the inverse of an anaerobic threshold. Maximal cardiopulmonary responses were achieved at 200 watts. During the final periods of exercise from 200 to 275/325 watts pulmonary ventilation did not significantly change but there was a decrease in the venous blood H+ concentration, and pO2 and in increase in the pCO2. Creatine supplementation at 25 g/day for five days did not improve exercise performance.
Self-Cooling Gradient Shell for Body Armor
2012-05-10
Silica gel 2.1 Filter paper pocket (no absorbent) 2.0 2 g Silica gel (150-Å pore size) + 2 g sodium polyacrylate (SPA) in filter paper pocket 2.7...layer of filter paper improved the temperature difference by an additional 0.5 °C. More-absorbent materials, such as sodium polyacrylate (SPA) or... sodium polyacrylate SPM scanning probe microscopy µm micrometer Wm-2 watts per square meter °C degrees Celsius
Very high power THz radiation sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carr, G.L.; Martin, Michael C.; McKinney, Wayne R.
2002-10-31
We report the production of high power (20 watts average, {approx} 1 Megawatt peak) broadband THz light based on coherent emission from relativistic electrons. Such sources are ideal for imaging, for high power damage studies and for studies of non-linear phenomena in this spectral range. We describe the source, presenting theoretical calculations and their experimental verification. For clarity we compare this source to one based on ultrafast laser techniques.
Case Study: Accelerating Process Improvement by Integrating the TSP and CMMI
2007-06-01
Could software development teams and indi- viduals apply similar principles to improve their work? Watts S . Humphrey , a founder of the process...was an authorized PSP instructor. At Schwalb’s urging, Watts Humphrey briefed the SLT on the PSP and TSP, and after the briefing, the team... Humphrey 96] Humphrey , Watts S . Introduction to the Personal Software Process. Boston, MA: Addison- Wesley Publishing Company, Inc., 1996 (ISBN
High specific energy and specific power aluminum/air battery for micro air vehicles
NASA Astrophysics Data System (ADS)
Kindler, A.; Matthies, L.
2014-06-01
Micro air vehicles developed under the Army's Micro Autonomous Systems and Technology program generally need a specific energy of 300 - 550 watt-hrs/kg and 300 -550 watts/kg to operate for about 1 hour. At present, no commercial cell can fulfill this need. The best available commercial technology is the Lithium-ion battery or its derivative, the Li- Polymer cell. This chemistry generally provides around 15 minutes flying time. One alternative to the State-of-the Art is the Al/air cell, a primary battery that is actually half fuel cell. It has a high energy battery like aluminum anode, and fuel cell like air electrode that can extract oxygen out of the ambient air rather than carrying it. Both of these features tend to contribute to a high specific energy (watt-hrs/kg). High specific power (watts/kg) is supported by high concentration KOH electrolyte, a high quality commercial air electrode, and forced air convection from the vehicles rotors. The performance of this cell with these attributes is projected to be 500 watt-hrs/kg and 500 watts/kg based on simple model. It is expected to support a flying time of approximately 1 hour in any vehicle in which the usual limit is 15 minutes.
Recent development on high-power tandem-pumped fiber laser
NASA Astrophysics Data System (ADS)
Zhou, Pu; Xiao, Hu; Leng, Jinyong; Zhang, Hanwei; Xu, Jiangmin; Wu, Jian
2016-11-01
High power fiber laser is attracting more and more attention due to its advantage in excellent beam quality, high electricto- optical conversion efficiency and compact system configuration. Power scaling of fiber laser is challenged by the brightness of pump source, nonlinear effect, modal instability and so on. Pumping active fiber by using high-brightness fiber laser instead of common laser diode may be the solution for the brightness limitation. In this paper, we will present the recent development of various kinds of high power fiber laser based on tandem pumping scheme. According to the absorption property of Ytterbium-doped fiber, Thulium-doped fiber and Holmium-doped fiber, we have theoretically studied the fiber lasers that operate at 1018 nm, 1178 nm and 1150 nm, respectively in detail. Consequently, according to the numerical results we have optimized the fiber laser system design, and we have achieved (1) 500 watt level 1018nm Ytterbium-doped fiber laser (2) 100 watt level 1150 nm fiber laser and 100 watt level random fiber laser (3) 30 watt 1178 nm Ytterbium-doped fiber laser, 200 watt-level random fiber laser. All of the above-mentioned are the record power for the corresponded type of fiber laser to the best of our knowledge. By using the high-brightness fiber laser operate at 1018 nm, 1178 nm and 1150 nm that we have developed, we have achieved the following high power fiber laser (1) 3.5 kW 1090 nm Ytterbium-doped fiber amplifier (2) 100 watt level Thulium-doped fiber laser and (3) 50 watt level Holmium -doped fiber laser.
The contribution of China’s emissions to global climate forcing
NASA Astrophysics Data System (ADS)
Li, Bengang; Gasser, Thomas; Ciais, Philippe; Piao, Shilong; Tao, Shu; Balkanski, Yves; Hauglustaine, Didier; Boisier, Juan-Pablo; Chen, Zhuo; Huang, Mengtian; Li, Laurent Zhaoxin; Li, Yue; Liu, Hongyan; Liu, Junfeng; Peng, Shushi; Shen, Zehao; Sun, Zhenzhong; Wang, Rong; Wang, Tao; Yin, Guodong; Yin, Yi; Zeng, Hui; Zeng, Zhenzhong; Zhou, Feng
2016-03-01
Knowledge of the contribution that individual countries have made to global radiative forcing is important to the implementation of the agreement on “common but differentiated responsibilities” reached by the United Nations Framework Convention on Climate Change. Over the past three decades, China has experienced rapid economic development, accompanied by increased emission of greenhouse gases, ozone precursors and aerosols, but the magnitude of the associated radiative forcing has remained unclear. Here we use a global coupled biogeochemistry-climate model and a chemistry and transport model to quantify China’s present-day contribution to global radiative forcing due to well-mixed greenhouse gases, short-lived atmospheric climate forcers and land-use-induced regional surface albedo changes. We find that China contributes 10% ± 4% of the current global radiative forcing. China’s relative contribution to the positive (warming) component of global radiative forcing, mainly induced by well-mixed greenhouse gases and black carbon aerosols, is 12% ± 2%. Its relative contribution to the negative (cooling) component is 15% ± 6%, dominated by the effect of sulfate and nitrate aerosols. China’s strongest contributions are 0.16 ± 0.02 watts per square metre for CO2 from fossil fuel burning, 0.13 ± 0.05 watts per square metre for CH4, -0.11 ± 0.05 watts per square metre for sulfate aerosols, and 0.09 ± 0.06 watts per square metre for black carbon aerosols. China’s eventual goal of improving air quality will result in changes in radiative forcing in the coming years: a reduction of sulfur dioxide emissions would drive a faster future warming, unless offset by larger reductions of radiative forcing from well-mixed greenhouse gases and black carbon.
The contribution of China's emissions to global climate forcing.
Li, Bengang; Gasser, Thomas; Ciais, Philippe; Piao, Shilong; Tao, Shu; Balkanski, Yves; Hauglustaine, Didier; Boisier, Juan-Pablo; Chen, Zhuo; Huang, Mengtian; Li, Laurent Zhaoxin; Li, Yue; Liu, Hongyan; Liu, Junfeng; Peng, Shushi; Shen, Zehao; Sun, Zhenzhong; Wang, Rong; Wang, Tao; Yin, Guodong; Yin, Yi; Zeng, Hui; Zeng, Zhenzhong; Zhou, Feng
2016-03-17
Knowledge of the contribution that individual countries have made to global radiative forcing is important to the implementation of the agreement on "common but differentiated responsibilities" reached by the United Nations Framework Convention on Climate Change. Over the past three decades, China has experienced rapid economic development, accompanied by increased emission of greenhouse gases, ozone precursors and aerosols, but the magnitude of the associated radiative forcing has remained unclear. Here we use a global coupled biogeochemistry-climate model and a chemistry and transport model to quantify China's present-day contribution to global radiative forcing due to well-mixed greenhouse gases, short-lived atmospheric climate forcers and land-use-induced regional surface albedo changes. We find that China contributes 10% ± 4% of the current global radiative forcing. China's relative contribution to the positive (warming) component of global radiative forcing, mainly induced by well-mixed greenhouse gases and black carbon aerosols, is 12% ± 2%. Its relative contribution to the negative (cooling) component is 15% ± 6%, dominated by the effect of sulfate and nitrate aerosols. China's strongest contributions are 0.16 ± 0.02 watts per square metre for CO2 from fossil fuel burning, 0.13 ± 0.05 watts per square metre for CH4, -0.11 ± 0.05 watts per square metre for sulfate aerosols, and 0.09 ± 0.06 watts per square metre for black carbon aerosols. China's eventual goal of improving air quality will result in changes in radiative forcing in the coming years: a reduction of sulfur dioxide emissions would drive a faster future warming, unless offset by larger reductions of radiative forcing from well-mixed greenhouse gases and black carbon.
Lewis, Gregory D.; Murphy, Ryan M.; Shah, Ravi V.; Pappagianopoulos, Paul P.; Malhotra, Rajeev; Bloch, Kenneth D.; Systrom, David M.; Semigran, Marc J.
2012-01-01
Background Elevated resting pulmonary arterial pressure (PAP) in patients with left ventricular systolic dysfunction (LVSD) purports a poor prognosis. However, PAP response patterns to exercise in LVSD and their relationship to functional capacity and outcomes have not been characterized. Methods and Results Sixty consecutive patients with LVSD (age 60±12 years, LV ejection fraction 0.31±0.07, mean±SD) and 19 controls underwent maximum incremental cardiopulmonary exercise testing with simultaneous hemodynamic monitoring. During low-level exercise (30 Watts), LVSD subjects compared to controls, had greater augmentation in mean PAPs (15±1 vs. 5±1 mmHg), transpulmonary gradients (5±1 vs. 1±1 mmHg), and effective PA elastance (0.05±0.02 vs. −0.03±0.01 mmHg/ml, p<0.0001 for all). A linear increment in PAP relative to work (0.28±0.12 mmHg/watt) was observed in 65% of LVSD patients, which exceeded that observed in controls (0.07±0.02 mmHg/watt, P<0.0001). Exercise capacity and survival was worse in patients with a PAP/watt slope above the median than in patients with a lower slope. In the remaining 35% of LVSD patients, exercise induced a steep initial increment in PAP (0.41±0.16 mmHg/watt) followed by a plateau. The plateau pattern, compared to a linear pattern, was associated with reduced peak VO2 (10.6±2.6 vs. 13.1±4.0 ml/kg/min, P=0.005), lower right ventricular stroke work index augmentation with exercise (5.7±3.8 vs. 9.7±5.0 g/m2, P=0.002), and increased mortality (HR 8.1, 95% CI 2.7-23.8, P<0.001). Conclusions A steep increment in PAP during exercise and failure to augment PAP throughout exercise are associated with decreased exercise capacity and survival in patients with LVSD, and may therefore represent therapeutic targets. Clinical Trial Information URL: http://www.clinicaltrials.gov. Unique Identifier: NCT00309790) PMID:21292991
Conceptual design of a 500 watt solar AMTEC space power system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ivanenok, J.F. III; Sievers, R.K.; Harty, R.B.
1995-12-31
Numerous design studies have been completed on Radioisotope powered Alkali Metal Thermal to Electric Converter (RAMTEC) power systems demonstrating their substantial increase in performance. Prior to recent advances in AMTEC technology and Thermal Energy Storage (TES), coupling AMTEC converters with a solar concentrator did not increase the performance of solar powered space power systems. This paper describes a conceptual design of an innovative, low cost, reliable, low mass, long life 500 watt Solar AMTEC (SAMTEC) power system, and the predicted system performance. The concept uses innovative, high voltage AMTEC cells, each containing 7 to 9 small electrolyte tubes, integrated withmore » an individual TES unit. These multi-tube AMTEC cells are identical to the AMTEC cells designed for radioisotope powered systems. The TES used in this conceptual design is the LiF-22%CaF{sub 2} unit currently being developed at NASA Lewis Research Center (LeRC) for the Solar Dynamic Ground Test Demonstration (SDGTD) Program. The system was designed to provide 500 watts of electrical power at 28 volts to a payload in Low Earth Orbit (LEO, 800 km, 28.5{degree} inclination) for a minimum lifetime of 5 years. The SAMTEC power system is predicted to have a specific power k of 5.3 to 8.9 W(e)/kg (including the concentrator, receiver, AMTEC cells, gimbals and drives, structure, power processing and control, and a 30% mass contingency) at the 500 watt power level, and 12 to 17 W(e)/kg at the 5,000 watt power level. The SAMTEC system, including all of the components listed above, is anticipated to cost $1,000/W(e) once development is complete and production begins. The SAMTEC system provides 92% of its Beginning of Life (BOL) power after a 5 year period in LEO, and SAMTEC systems should provide 10 to 15 years of life in LEO. Current AMTEC cells have demonstrated 18% efficiency in the laboratory and have been heated radiatively, with propane flames and electrical resistance heaters.« less
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2013 CFR
2013-01-01
... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2014 CFR
2014-01-01
... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...
10 CFR 431.282 - Test Procedures [Reserved
Code of Federal Regulations, 2012 CFR
2012-01-01
... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...
10 CFR 431.202 - Definitions concerning illuminated exit signs.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Section 431.202 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN... watts (W). For exit sign models with rechargeable batteries, input power demand shall be measured with batteries at full charge. [70 FR 60417, Oct. 18, 2005, as amended at 71 FR 71372, Dec. 8, 2006] Test...
10 CFR 431.202 - Definitions concerning illuminated exit signs.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Section 431.202 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN... watts (W). For exit sign models with rechargeable batteries, input power demand shall be measured with batteries at full charge. [70 FR 60417, Oct. 18, 2005, as amended at 71 FR 71372, Dec. 8, 2006] Test...
Heat pipe cooled power magnetics
NASA Technical Reports Server (NTRS)
Chester, M. S.
1979-01-01
A high frequency, high power, low specific weight (0.57 kg/kW) transformer developed for space use was redesigned with heat pipe cooling allowing both a reduction in weight and a lower internal temperature rise. The specific weight of the heat pipe cooled transformer was reduced to 0.4 kg/kW and the highest winding temperature rise was reduced from 40 C to 20 C in spite of 10 watts additional loss. The design loss/weight tradeoff was 18 W/kg. Additionally, allowing the same 40 C winding temperature rise as in the original design, the KVA rating is increased to 4.2 KVA, demonstrating a specific weight of 0.28 kg/kW with the internal loss increased by 50W. This space environment tested heat pipe cooled design performed as well electrically as the original conventional design, thus demonstrating the advantages of heat pipes integrated into a high power, high voltage magnetic. Another heat pipe cooled magnetic, a 3.7 kW, 20A input filter inductor was designed, developed, built, tested, and described. The heat pipe cooled magnetics are designed to be Earth operated in any orientation.
Studies On Endoscopic Local Hyperthermia Using Nd-YAG Laser
NASA Astrophysics Data System (ADS)
Tsunekawa, H.; Kanemaki, N.; Furusawa, A.; Hotta, M.; Kuroiwa, A.; Nishida, M.; Mori, N.; Watanabe, Y.; Morise, K.; Iizuka, A.
1987-03-01
Attempting a new method of laser irradiation for depressed gastric carcinoma, using a newly developed interstitial probe and laser attenuator, we applied local hyperthermia with prolonged low watt contact irradiation. Experimental studies were performed with this probe, using BDF1 mice injected hypodermically with Lewis lung carcinoma. A laser power of 2.0 w at the tip of fiber produced the most desirable temperature curve, about 43 - 60°C at the irradiation site. Clinical applications were carried out on 15 patients with early gastric carcinoma (mainly depressed), 10 preoperative pilot cases and 5 inoperable cases. In follow-up operations and biopsies gastric carcinoma was found to have completely dis-appeared in 2 of the preoperative and 4 of the inoperable cases. In the remaining 8 preoperative cases residual traces of carcinoma were found at the margin of the laser ulcer, but not at the bottom of it. We propose that endoscopic local hyperthermia using interstitial probe and low power irradiation (2.0 W) is the safest and most suitable method of dealing with depressed carcinoma.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keshner, M. S.; Arya, R.
2004-10-01
Hewlett Packard has created a design for a ''Solar City'' factory that will process 30 million sq. meters of glass panels per year and produce 2.1-3.6 GW of solar panels per year-100x the volume of a typical, thin-film, solar panel manufacturer in 2004. We have shown that with a reasonable selection of materials, and conservative assumptions, this ''Solar City'' can produce solar panels and hit the price target of $1.00 per peak watt (6.5x-8.5x lower than prices in 2004) as the total price for a complete and installed rooftop (or ground mounted) solar energy system. This breakthrough in the pricemore » of solar energy comes without the need for any significant new invention. It comes entirely from the manufacturing scale of a large plant and the cost savings inherent in operating at such a large manufacturing scale. We expect that further optimizations from these simple designs will lead to further improvements in cost. The manufacturing process and cost depend on the choice for the active layer that converts sunlight into electricity. The efficiency by which sunlight is converted into electricity can range from 7% to 15%. This parameter has a large effect on the overall price per watt. There are other impacts, as well, and we have attempted to capture them without creating undue distractions. Our primary purpose is to demonstrate the impact of large-scale manufacturing. This impact is largely independent of the choice of active layer. It is not our purpose to compare the pro's and con's for various types of active layers. Significant improvements in cost per watt can also come from scientific advances in active layers that lead to higher efficiency. But, again, our focus is on manufacturing gains and not on the potential advances in the basic technology.« less
NASA Technical Reports Server (NTRS)
1996-01-01
Basic requirement of 978.59 watts per Panel output @ 58.9 volts B.O.L. was met on an average basis per agreement with NASA. Lower grade Cells were used on the shadowed Panel (Boom shadow) to maximize available power to the Spacecraft. The average output @ 58.9 volts was 991 watts. The outputs of the four t4) Panels ranged from 960 to 1,022 watts. The Panels successfully passed environmental testing at TRW to the contract specification and subsequent testing at NASA which involved output measurements at elevated temperatures. As this type of Array had never previously been built by TRW (aluminum Substrate with 4 cm x 4.4 cm GaAs Cells), the TRMM Program was a development effort combined with a Qual and Flight production effort. The most significant technical problem was Cell cracking during Qual thermal cycling. The cracking problem was determined to be generic within our Solar Array factory in the application of GaAs Cells to our designs. As a result, a TRW funded manufacturing process verification panel (known as the Manufacturing Verification Panel) was built to demonstrate our ability to properly apply GaAs Cells. The original Qual Panel comprised three (3) design variations with respect to Coverglass-to-Cell and Cell-to-Substrate adhesives. The intent was to qualify multiple designs in case one or more failed. When two of the three combinations failed due to excessive Cell breakage during thermal cycling, NASA was reluctant to allow Flight production based on the one remaining good Qual Panel Quadrant. This issue was pivotal for continuing the contract. Facts and recommendations are as follows: (1) The cause of the excessive cracking was never determined. and (2) The areas where the excessive cracking occurred utilized DC93-500 glassing adhesive which was NASA approved, and had been widely used by TRW on a multitude of projects.
Oscillation in O2 uptake in impulse exercise.
Yano, T; Afroundeh, R; Yamanaka, R; Arimitsu, T; Lian, C S; Shirakawa, K; Yunoki, T
2014-06-01
The purpose of the present study was to examine 1) whether O(2) uptake (VO(2)) oscillates during light exercise and 2) whether the oscillation is enhanced after impulse exercise. After resting for 1 min on a bicycle seat, subjects performed 5-min pre-exercise with 25 watts work load, 10-s impulse exercise with 200 watts work load and 15-min post exercise with 25 watts work load at 80 rpm. VO(2) during pre-exercise significantly increased during impulse exercise and suddenly decreased and re-increased until 23 s after impulse exercise. In the cross correlation between heart rate (HR) and VO(2) after impulse exercise, VO(2) strongly correlated to HR with a time delay of -4 s. Peak of power spectral density (PSD) in HR appeared at 0.0039 Hz and peak of PSD in VO(2) appeared at 0.019 Hz. The peak of the cross power spectrum between VO(2) and HR appeared at 0.0078 Hz. The results suggested that there is an oscillation in O(2) uptake during light exercise that is associated with the oscillation in O(2) consumption in active muscle. The oscillation is enhanced not only by change in O(2) consumption but also by O(2) content transported from active muscle to the lungs.
Case Study: Accelerating Process Improvement by Integrating the TSP and CMMI
2005-12-01
improve their work? Watts S . Humphrey , a founder of the process improvement initiative at the SEI, de- cided to apply SW-CMM principles to the...authorized PSP instructor. At Schwalb’s urging, Watts Humphrey briefed the SLT on the PSP and TSP, and after the briefing, the team understood...hefley.html. [ Humphrey 96] Humphrey , Watts S . Introduction to the Personal Software Process. Boston, MA: Addison-Wesley Publishing Company, Inc., 1996
Updating the TSP Quality Plan Using Monte Carlo Simulation
2010-08-01
TSP is the attention to quality or, more accurately, the ability to manage product defects. In fact, TSP creator Watts S . Humphrey says: ... defect...teams at Hill AFB recently started using this technique and are still gathering data on its useful- ness.u References 1. Humphrey , Watts S . TSP...Leading a Development Team. Upper Saddle River, NJ: Addison-Wesley, 2006. Page 138. 2. Humphrey , Watts S . TSP – Leading a Development Team. Upper Saddle
1997-12-01
Watts Humphrey and is described in his book A Discipline for Software Engineering [ Humphrey 95]. Its intended use is to guide the planning and...Pat; Humphrey , Watts S .; Khajenoori, Soheil; Macke, Susan; & Matvya, Annette. "Introducing the Personal Software Process: Three Industry Case... Humphrey 95] Humphrey , Watts S . A Discipline for Software Engineering. Reading, Ma.: Addison-Wesley, 1995. [Mauchly 40] Mauchly, J.W. "Significance
NASA Astrophysics Data System (ADS)
Cosandier, F.; Eichenberger, A.; Baumann, H.; Jeckelmann, B.; Bonny, M.; Chatagny, V.; Clavel, R.
2014-04-01
There is a firm will in the metrology community to redefine the kilogram in the International System of units by linking it to a fundamental physical constant. The watt balance is a promising way to link the mass unit to the Planck constant h. At the Federal Institute of Metrology METAS a second watt balance experiment is under development. A decisive part of the METAS Mark II watt balance is the mechanical linear guiding system. The present paper discusses the development and the metrological characteristics of two guiding systems that were conceived by the Laboratoire de Systèmes Robotiques of EPFL and built using flexure mechanical elements. Integration in the new setup is also described.
CONDOR: Long endurance high altitude vehicle, volume 5
NASA Technical Reports Server (NTRS)
Andrews, L. Cullen; Augsburger, Bill; Cote, Thomas; Ghitea, Mihael; Lee, Il Sik; Lee, Susik; Leong, Gary
1988-01-01
The results of a design study resulting in the proposed CONDOR aircraft are presented. The basic requirements are for the aircraft to maintain continuous altitude at or above 45,000 feet for at least a 3-day mission, be able to comfortably support a two-man crew during this period with their field of vision not obstructed to a significant degree, carry a payload of 200 pounds, and provide a power supply to the payload of 2000 watts. The take-off and landing distances must be below 5000. feet, and time to reach cruise altitude must not exceed 3 hours. The subjects discussed are configuration selection, structural analysis, stability and control, crew and payload accomodations, and economic estimates.
Comparative Study of Light Sources for Household
NASA Astrophysics Data System (ADS)
Pawlak, Andrzej; Zalesińska, Małgorzata
2017-03-01
The article describes test results that provided the ground to define and evaluate basic photometric, colorimetric and electric parameters of selected, widely available light sources, which are equivalent to a traditional incandescent 60-Watt light bulb. Overall, one halogen light bulb, three compact fluorescent lamps and eleven LED light sources were tested. In general, it was concluded that in most cases (branded products, in particular) the measured and calculated parameters differ from the values declared by manufacturers only to a small degree. LED sources prove to be the most beneficial substitute for traditional light bulbs, considering both their operational parameters and their price, which is comparable with the price of compact fluorescent lamps or, in some instances, even lower.
Advances in high-performance cryocoolers and production variants at Raytheon Infrared Operations
NASA Astrophysics Data System (ADS)
Ross, Bradley A.; Black, Stephen H.
2001-10-01
Raytheon has consolidated the products and expertise of the former Hughes Mahwah (Magnavox) and Torrance cryocooler operations to the Raytheon Infrared Operations (RIO) located in Goleta, CA (formerly SBRC). Co-location of the cryocooler operations with the detector/dewar operations yields infrared systems with reduced cost. This paper describes the current capabilities of the linear and rotary cryocooler products as well as developments underway and planned. Development goals include cost reduction, high performance while operating in extreme environmental conditions (> 90°C skin temperatures), and long life (> 20,000 hrs). Technologies developed by a Raytheon sister division for space cryocoolers are now being applied to tactical cryocoolers at RIO. Data, specifications, and a technology roadmap for the product-line cryocoolers encompassing cooling capacities including 0.2-, 0.35-, 0.75-, 1.0- and 1.75-watt ranges will be shown.
Single Piezo-Actuator Rotary-Hammering (SPaRH) Drill
NASA Technical Reports Server (NTRS)
Sherrit, Stewart (Inventor); Bao, Xiaoqi (Inventor); Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor)
2014-01-01
A Single Piezo-Actuator Rotary-Hammering (SPaRH) Drill includes a horn actuator having high power piezoelectric materials and a flexure pre-stress to increase the actuators effectiveness. The drill is a low mass, low power, compact coring drill measuring 20-cm high by 7-cm diameter and having a total weight of 2 kg including drive electronics. Using an average power of 50-Watts, the drill basalt is expected to cut basalt at a rate of 0.2 cm/min down to depth of 10-cm and create cuttings and an intact core. The drill is expected to operate under different environments including Martian ambient (6 Torr and down to -50 degree C), and liquid nitrogen temperatures (77 K) and low pressure (<<1 Torr) to simulate lunar polar and Europa conditions. Materials expected to be sampled include Kaolinite, Saddleback Basalt, Limestone, Volcanic Breccia, Siltstone, ice, permafrost and layered rocks with different hardness.
Flat-plate solar array project. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
Callaghan, W.; Mcdonald, R.
1986-01-01
In 1975, the U.S. Government contracted the Jet Propulsion Lab. to develop, by 1985, in conjunction with industry, the photovoltaics (PV) module and array technology required for widespread use of photovoltaics as a significant terrestrial energy source. As a result, a project that eventually became known as the Flat Plate Solar Array (FSA) Project was formed to manage an industry, university, and Government team to perform the necessary research and development. The original goals were to achieve widespread commercial use of PV modules and arrays through the development of technology that would allow them to be profitably sold for $1.07/peak watts (1985 dollars). A 10% module conversion efficiency and a 20 year lifetime were also goals. It is intended that the executive summary provide the means by which one can gain a perspective on 11 years of terrestrial photovoltaic research and development conducted by the FSA Project.
Low-cost solar array project progress and plans
NASA Technical Reports Server (NTRS)
Callaghan, W. T.
1981-01-01
The considered project is part of the DOE Photovoltaic Technology and Market Development Program. This program is concerned with the development and the utilization of cost-competitive photovoltaic systems. The project has the objective to develop, by 1986, the national capability to manufacture low-cost, long-life photovoltaic arrays at production rates that will realize economies of scale, and at a price of less than $0.70/watt. The array performance objectives include an efficiency greater than 10% and an operating lifetime longer than 20 years. The objective of the silicon material task is to establish the practicality of processes for producing silicon suitable for terrestrial photovoltaic applications at a price of $14/kg. The large-area sheet task is concerned with the development of process technology for sheet formation. Low-cost encapsulation material systems are being developed in connection with the encapsulation task. Another project goal is related to the development of economical process sequences.
Design and analysis study of a spacecraft optical transceiver package
NASA Technical Reports Server (NTRS)
Lambert, S. G.
1985-01-01
A detailed system level design of an Optical Transceiver Package (OPTRANSPAC) for a deep space vehicle whose mission is outer planet exploration is developed. In addition to the terminal design, this study provides estimates of the dynamic environments to be encountered by the transceiver throughout its mission life. Optical communication link analysis, optical thin lens design, electronic functional design and mechanical layout and packaging are employed in the terminal design. Results of the study describe an Optical Transceiver Package capable of communicating to an Earth Orbiting Relay Station at a distance of 10 Astronomical Units (AU) and data rates up to 100 KBPS. The transceiver is also capable of receiving 1 KBPS of command data from the Earth Relay. The physical dimensions of the terminal are contained within a 3.5' x 1.5' x 2.0' envelope and the transceiver weight and power are estimated at 52.2 Kg (115 pounds) and 57 watts, respectively.
Theoretical analysis and Vsim simulation of a low-voltage high-efficiency 250 GHz gyrotron
NASA Astrophysics Data System (ADS)
An, Chenxiang; Zhang, Dian; Zhang, Jun; Zhong, Huihuang
2018-02-01
Low-voltage, high-frequency gyrotrons with hundreds of watts of power are useful in radar, magnetic resonance spectroscopy and plasma diagnostic applications. In this paper, a 10 kV, 478 W, 250 GHz gyrotron with an efficiency of nearly 40% and a pitch ratio of 1.5 was designed through linear and nonlinear numerical analyses and Vsim particle-in-cell (PIC) simulation. Vsim is a highly efficient parallel PIC code, but it has seldom been used to carry out electron beam wave interaction simulations of gyro-devices. The setting up of the parameters required for the Vsim simulations of the gyrotron is presented. The results of Vsim simulations agree well with that of nonlinear numerical calculation. The commercial software Vsim7.2 completed the 3D gyrotron simulation in 80 h using a 20 core, 2.2 GHz personal computer with 256 GBytes of memory.
ERIC Educational Resources Information Center
Tas, Murat; Sinanoglu, Ahmet
2017-01-01
In the research it was aimed to examine the effects of basic table tennis trainings, which were implemented on girls aged 10-12 for 16 weeks, on certain physical and physiological parameters. A total of 40 students, as randomly selected 20 test groups and 20 control groups at an age range of 10-12 participated in the research. These students were…
1995-06-01
Energy efficient, 30 and 40 watt ballasts are Rapid Start, thermally protected, automatic resetting. Class P, high or low power factor as required...BALLASTS Energy efficient, 30 ana 40 watt Rapic Start, thermally protected, automatic resetting. Class P. high power factor, CEM, sound rated A. unless...BALLASTS Energy efficient, 40 Watt Rapid Start, thermally protected, automatic resetting, Class P, high power factor, CBM, sound rated A, unless
Social Network Analysis in Frontier Capital Markets
2012-06-01
developed by Watts and Strogatz measures the extent to which clusters or cliques exist in a network [WS98]. The clustering coefficent of each individual...Coefficient Watts- Strogatz 0.8039 0.8222 0.7227 Total Degree Centralization 0.0618 0.0940 0.0612 Betweenness Centralization 0.0909 0.1256 0.0646 Closeness...Fragmentation 0.6099 0.5304 0.5308 Clustering Coefficient Watts- Strogatz 0.5281 0.6607 0.6360 Total Degree Centralization 0.0153 0.0360 0.0171
2010-12-01
PSP and TSP books by Watts Humphrey or in the TSP-MT (multi-team) process extension. A few additional items should be created, e.g., see OPD-2...Institute, Carnegie Mellon University, 2000. www.sei.cmu.edu/library/abstracts/reports/00tr023.cfm [ Humphrey 2005] Humphrey , Watts S . PSP : A Self... Humphrey 2006] Humphrey , Watts S . TSP: Coaching Development Teams. Addison Wesley, 2006 (ISBN 978- 0201731132). www.sei.cmu.edu/library/abstracts/
Nilsson, Håkan; Juslin, Peter; Winman, Anders
2016-01-01
Costello and Watts (2014) present a model assuming that people's knowledge of probabilities adheres to probability theory, but that their probability judgments are perturbed by a random noise in the retrieval from memory. Predictions for the relationships between probability judgments for constituent events and their disjunctions and conjunctions, as well as for sums of such judgments were derived from probability theory. Costello and Watts (2014) report behavioral data showing that subjective probability judgments accord with these predictions. Based on the finding that subjective probability judgments follow probability theory, Costello and Watts (2014) conclude that the results imply that people's probability judgments embody the rules of probability theory and thereby refute theories of heuristic processing. Here, we demonstrate the invalidity of this conclusion by showing that all of the tested predictions follow straightforwardly from an account assuming heuristic probability integration (Nilsson, Winman, Juslin, & Hansson, 2009). We end with a discussion of a number of previous findings that harmonize very poorly with the predictions by the model suggested by Costello and Watts (2014). (c) 2015 APA, all rights reserved).
Optimization Of Shear Modes To Produce Enhanced Bandwidth In Ghz GaP Bragg Cells
NASA Astrophysics Data System (ADS)
Soos, J., I.; Rosemeier, R. G.; Rosenbaum, J.
1988-02-01
Applications of Gallium Phosphide (GaP) acousto-optic devices, at wavelengths from 570nm - 1.06um seem to be ideal for fiber optic modulators, scanners, deflectors, frequency shifters, Q-switches and mode lockers. One of the major applications are for RF spectrometers in early warning radar receivers and auto-correlators. Longitudinal GaP acousto-optic Bragg cells which have respectively operational frequencies in the range of 200 MHz - 3 GHz and diffraction efficiencies in the range of 120%/RF watt to 1%/RF watt have recently been fabricated. Comparatively, shear GaP devices which have operational frequencies in the range of 200 MHz to 2 GHz and diffraction efficiencies from 80%/RF watt to 7%/RF watt have also been constructed.
Wheelock, H
2016-06-01
Dr William Cullen (1710-1790) was a leading physician of the Enlightenment era. As professor in Edinburgh he became the most influential teacher of theoretical and practical medicine in 18th century Britain. A renowned private practitioner, Cullen systematically archived his postal 'consultations', now held by the Royal College of Physicians of Edinburgh. Initially Cullen preserved his replies as transcriptions, but from April 1781 he began using a mechanical copier, newly devised by the Scottish engineer James Watt. This paper describes the development, promotion and functioning of Watt's copier and considers Cullen's own adoption of the machine. It is suggested that with Cullen's adoption of Watt's copier, medical record keeping entered a new historical phase comparable with the recent digital revolution.
Zhang, Yan; Su, Linan; Zhang, Yunrong; Wang, Qiang; Yang, Dachun; Li, De; Yang, Yongjian; Ma, Shuangtao
2017-01-01
Background Catheter-based renal denervation (RDN) is a promising approach to treat hypertension, but innervation patterns limit the response to endovascular RDN and the post-procedural renal artery narrowing or stenosis questions the endovascular ablation strategy. This study was performed to investigate the anti-hypertensive and target organ protective effects of perivascular RDN in spontaneously hypertensive rats (SHR). Methods SHR and normotensive Wistar-Kyoto (WKY) rats were divided into sham group (n = 10), radiofrequency ablation group (n = 20) in which rats received bilateral perivascular ablation with radiofrequency energy (2 watts), and chemical (10% phenol in 95% ethanol) ablation group (n = 12). The tail-cuff blood pressure was measured before the ablation and on day 14 and day 28 after the procedure. The plasma levels of creatinine, urea nitrogen, and catecholamines, urinary excretion of electrolytes and protein, and myocardial and glomerular fibrosis were analyzed and compared among the groups on day 28 after the procedure. Results We identified that 2-watt is the optimal radiofrequency power for perivascular RDN in rats. Perivascular radiofrequency and chemical ablation achieved roughly comparable blood pressure reduction in SHR but not in WKY on day 14 and day 28 following the procedure. Radiofrequency-mediated ablation substantially destroyed the renal nerves surrounding the renal arteries of both SHR and WKY without damaging the renal arteries and diminished the expression of tyrosine hydroxylase, the enzyme marker for postganglionic sympathetic nerves. Additionally, perivascular radiofrequency ablation also decreased the plasma catecholamines of SHR. Interestingly, both radiofrequency and chemical ablation decreased the myocardial and glomerular fibrosis of SHR, while neither increased the plasma creatinine and blood urea nitrogen nor affected the urinary excretion of electrolytes and protein when compared to sham group. Conclusions Radiofrequency-mediated perivascular RDN may become a feasible procedure against hypertension, and provide similar anti-hypertensive and target organ protective effects as does the chemical ablation. PMID:28453557
Wei, Shujie; Li, Dan; Zhang, Yan; Su, Linan; Zhang, Yunrong; Wang, Qiang; Yang, Dachun; Li, De; Yang, Yongjian; Ma, Shuangtao
2017-01-01
Catheter-based renal denervation (RDN) is a promising approach to treat hypertension, but innervation patterns limit the response to endovascular RDN and the post-procedural renal artery narrowing or stenosis questions the endovascular ablation strategy. This study was performed to investigate the anti-hypertensive and target organ protective effects of perivascular RDN in spontaneously hypertensive rats (SHR). SHR and normotensive Wistar-Kyoto (WKY) rats were divided into sham group (n = 10), radiofrequency ablation group (n = 20) in which rats received bilateral perivascular ablation with radiofrequency energy (2 watts), and chemical (10% phenol in 95% ethanol) ablation group (n = 12). The tail-cuff blood pressure was measured before the ablation and on day 14 and day 28 after the procedure. The plasma levels of creatinine, urea nitrogen, and catecholamines, urinary excretion of electrolytes and protein, and myocardial and glomerular fibrosis were analyzed and compared among the groups on day 28 after the procedure. We identified that 2-watt is the optimal radiofrequency power for perivascular RDN in rats. Perivascular radiofrequency and chemical ablation achieved roughly comparable blood pressure reduction in SHR but not in WKY on day 14 and day 28 following the procedure. Radiofrequency-mediated ablation substantially destroyed the renal nerves surrounding the renal arteries of both SHR and WKY without damaging the renal arteries and diminished the expression of tyrosine hydroxylase, the enzyme marker for postganglionic sympathetic nerves. Additionally, perivascular radiofrequency ablation also decreased the plasma catecholamines of SHR. Interestingly, both radiofrequency and chemical ablation decreased the myocardial and glomerular fibrosis of SHR, while neither increased the plasma creatinine and blood urea nitrogen nor affected the urinary excretion of electrolytes and protein when compared to sham group. Radiofrequency-mediated perivascular RDN may become a feasible procedure against hypertension, and provide similar anti-hypertensive and target organ protective effects as does the chemical ablation.
US Navy program in small cryocoolers
NASA Technical Reports Server (NTRS)
Nisenoff, M.; Edelsack, E. A.
1983-01-01
A Navy program to develop fractional-watt cryocoolers capable of operating below 10 K is discussed. Several varieties of Stirling coolers were built and are under evaluation. In addition, helium gas compressors designed for use with small, closed cycle Joule-Thomson coolers are under development. An overview of the technical aspects of the program are presented.
A Select Survey of Campus Radio Stations.
ERIC Educational Resources Information Center
Drake, H.
To ascertain the continued need for a campus radio station at 10 watts and to justify a subsequent increase in power, the student radio station at Auburn University (Alabama) conducted surveys of college radio stations, emphasizing facilities in the southeast United States. Some of the findings of the surveys indicated that in the southeast and…
A spectral radiance comparison of a noise tube and a HgXe arc lamp between 60 GHz and 600 GHz
NASA Technical Reports Server (NTRS)
Heaney, J. B.; Stewart, K. P.; Boucarut, R. A.; Moller, K. D.; Zoeller, R.
1987-01-01
The relative spectral radiance of a noise tube, model TN-167, designed for the frequency range 90-140 GHz (3.3 mm to 2.1 mm) was compared to that from a 200-watt high pressure HgXe arc lamp over the wavelength region from 0.5 to about 5 mm. A Michelson Fourier transform spectrometer and a lamellar grating instrument were used in conjunction with liquid helium-cooled bolometers of NEP 10 to the -12th to 10 to the -14th watt/(Hz) exp 1/2 to measure relative spectral radiant power. With this instrumental arrangement, the noise tube exhibited a very sharp low frequency cutoff at about 2.2/cm. The HgXe arc lamp emitted more radiant power than the noise tube in the wavelength region below 3 mm (100 GHz) down to 0.5 mm. Above 3 mm, the noise tube had a stronger output. The noise tube spectral radiance shifted to lower frequencies when the input current was lowered from 125 mA to 50 mA.
Observation of the 63 micron (0 1) emission line in the Orion and Omega Nebulae
NASA Technical Reports Server (NTRS)
Melnick, G.; Gull, G. E.; Harwit, M.
1978-01-01
The 63 micron fine structure transition P4 : 3Pl yields 3P2 for neutral atomic oxygen was obtained during a series of flights at an altitude of approximately 13.7 km. In the Orion Nebula (M42), the observed line strength was 8 x 10 to the minus 15 power watt cm/2 which is estimated to be approximately 0.3 o/o of the energy radiated at all wavelengths. For the Omega Nebulae (M17), the line strength was 2.4 x 10 to the minus 15 power watt cm/2, and the fraction of the total radiated power was slightly higher. These figures refer to a 4' x 6' field of view centered on the peak for infrared emission from each source. The uncertainty in the line strength is approximately 50% and is caused by variable water vapor absorption along the flight path of the airplane. The line position estimate is 63.2 micron (+0.1, -0.2) micron. The prime uncertainty is due to the uncertain position of the (0 I) emitting regions in the field of view.
Automating Visualization Service Generation with the WATT Compiler
NASA Astrophysics Data System (ADS)
Bollig, E. F.; Lyness, M. D.; Erlebacher, G.; Yuen, D. A.
2007-12-01
As tasks and workflows become increasingly complex, software developers are devoting increasing attention to automation tools. Among many examples, the Automator tool from Apple collects components of a workflow into a single script, with very little effort on the part of the user. Tasks are most often described as a series of instructions. The granularity of the tasks dictates the tools to use. Compilers translate fine-grained instructions to assembler code, while scripting languages (ruby, perl) are used to describe a series of tasks at a higher level. Compilers can also be viewed as transformational tools: a cross-compiler can translate executable code written on one computer to assembler code understood on another, while transformational tools can translate from one high-level language to another. We are interested in creating visualization web services automatically, starting from stand-alone VTK (Visualization Toolkit) code written in Tcl. To this end, using the OCaml programming language, we have developed a compiler that translates Tcl into C++, including all the stubs, classes and methods to interface with gSOAP, a C++ implementation of the Soap 1.1/1.2 protocols. This compiler, referred to as the Web Automation and Translation Toolkit (WATT), is the first step towards automated creation of specialized visualization web services without input from the user. The WATT compiler seeks to automate all aspects of web service generation, including the transport layer, the division of labor and the details related to interface generation. The WATT compiler is part of ongoing efforts within the NSF funded VLab consortium [1] to facilitate and automate time-consuming tasks for the science related to understanding planetary materials. Through examples of services produced by WATT for the VLab portal, we will illustrate features, limitations and the improvements necessary to achieve the ultimate goal of complete and transparent automation in the generation of web services. In particular, we will detail the generation of a charge density visualization service applicable to output from the quantum calculations of the VLab computation workflows, plus another service for mantle convection visualization. We also discuss WATT-LIVE [2], a web-based interface that allows users to interact with WATT. With WATT-LIVE users submit Tcl code, retrieve its C++ translation with various files and scripts necessary to locally install the tailor-made web service, or launch the service for a limited session on our test server. This work is supported by NSF through the ITR grant NSF-0426867. [1] Virtual Laboratory for Earth and Planetary Materials, http://vlab.msi.umn.edu, September 2007. [2] WATT-LIVE website, http://vlab2.scs.fsu.edu/watt-live, September 2007.
NASA Astrophysics Data System (ADS)
Pukhovskaya, S. G.; Ivanova, Yu. B.; Nam, Dao The; Vashurin, A. S.
2014-10-01
Spectrophotometric titration is used to study the basic properties of a series of porphyrins with a continuously increasing degree of macrocycle deformation resulting from the introduction of strong electron-withdrawing substituents: 2,3,7,8,12,13,17,18-octaethylporphyrin ( I), 5-nitro-2,3,7,8,12,13,17,18-octaethylporphyrin ( II), 5,15-dinitro-2,3,7,8,12,13,17,18-octaethylporphyrin ( III), 5,10,15-trinitro-2,3,7,8,12,13,17,18-octaethylporphyrin ( IV), and 5,10,15,20-tetranitro-2,3,7,8,12,13,17,18-octaethylporphyrin ( V). It is found that the values of log K b (total basicity constants) obtained for the investigated compounds consistently diminish with an increase in the number of meso-substituents: 11.85 ( I) > 10.45 ( II) > 10.31 ( III) > 10.23 ( IV) > 9.56 ( V). It is shown that two opposing factors, the steric and electronic effects of the substituents, change the basic properties of the above series of compounds.
Crupi, Vincenzo; Tentori, Katya
2016-01-01
According to Costello and Watts (2014), probability theory can account for key findings in human judgment research provided that random noise is embedded in the model. We concur with a number of Costello and Watts's remarks, but challenge the empirical adequacy of their model in one of their key illustrations (the conjunction fallacy) on the basis of recent experimental findings. We also discuss how our argument bears on heuristic and rational thinking. (c) 2015 APA, all rights reserved).
Hamrick, Jennifer L; Hamrick, Justin T; Lee, Jennifer K; Lee, Benjamin H; Koehler, Raymond C; Shaffner, Donald H
2014-04-14
End-tidal carbon dioxide (ETCO2) correlates with systemic blood flow and resuscitation rate during cardiopulmonary resuscitation (CPR) and may potentially direct chest compression performance. We compared ETCO2-directed chest compressions with chest compressions optimized to pediatric basic life support guidelines in an infant swine model to determine the effect on rate of return of spontaneous circulation (ROSC). Forty 2-kg piglets underwent general anesthesia, tracheostomy, placement of vascular catheters, ventricular fibrillation, and 90 seconds of no-flow before receiving 10 or 12 minutes of pediatric basic life support. In the optimized group, chest compressions were optimized by marker, video, and verbal feedback to obtain American Heart Association-recommended depth and rate. In the ETCO2-directed group, compression depth, rate, and hand position were modified to obtain a maximal ETCO2 without video or verbal feedback. After the interval of pediatric basic life support, external defibrillation and intravenous epinephrine were administered for another 10 minutes of CPR or until ROSC. Mean ETCO2 at 10 minutes of CPR was 22.7±7.8 mm Hg in the optimized group (n=20) and 28.5±7.0 mm Hg in the ETCO2-directed group (n=20; P=0.02). Despite higher ETCO2 and mean arterial pressure in the latter group, ROSC rates were similar: 13 of 20 (65%; optimized) and 14 of 20 (70%; ETCO2 directed). The best predictor of ROSC was systemic perfusion pressure. Defibrillation attempts, epinephrine doses required, and CPR-related injuries were similar between groups. The use of ETCO2-directed chest compressions is a novel guided approach to resuscitation that can be as effective as standard CPR optimized with marker, video, and verbal feedback.
Femtosecond response of polyatomic molecules to ultra-intense hard X-rays.
Rudenko, A; Inhester, L; Hanasaki, K; Li, X; Robatjazi, S J; Erk, B; Boll, R; Toyota, K; Hao, Y; Vendrell, O; Bomme, C; Savelyev, E; Rudek, B; Foucar, L; Southworth, S H; Lehmann, C S; Kraessig, B; Marchenko, T; Simon, M; Ueda, K; Ferguson, K R; Bucher, M; Gorkhover, T; Carron, S; Alonso-Mori, R; Koglin, J E; Correa, J; Williams, G J; Boutet, S; Young, L; Bostedt, C; Son, S-K; Santra, R; Rolles, D
2017-06-01
X-ray free-electron lasers enable the investigation of the structure and dynamics of diverse systems, including atoms, molecules, nanocrystals and single bioparticles, under extreme conditions. Many imaging applications that target biological systems and complex materials use hard X-ray pulses with extremely high peak intensities (exceeding 10 20 watts per square centimetre). However, fundamental investigations have focused mainly on the individual response of atoms and small molecules using soft X-rays with much lower intensities. Studies with intense X-ray pulses have shown that irradiated atoms reach a very high degree of ionization, owing to multiphoton absorption, which in a heteronuclear molecular system occurs predominantly locally on a heavy atom (provided that the absorption cross-section of the heavy atom is considerably larger than those of its neighbours) and is followed by efficient redistribution of the induced charge. In serial femtosecond crystallography of biological objects-an application of X-ray free-electron lasers that greatly enhances our ability to determine protein structure-the ionization of heavy atoms increases the local radiation damage that is seen in the diffraction patterns of these objects and has been suggested as a way of phasing the diffraction data. On the basis of experiments using either soft or less-intense hard X-rays, it is thought that the induced charge and associated radiation damage of atoms in polyatomic molecules can be inferred from the charge that is induced in an isolated atom under otherwise comparable irradiation conditions. Here we show that the femtosecond response of small polyatomic molecules that contain one heavy atom to ultra-intense (with intensities approaching 10 20 watts per square centimetre), hard (with photon energies of 8.3 kiloelectronvolts) X-ray pulses is qualitatively different: our experimental and modelling results establish that, under these conditions, the ionization of a molecule is considerably enhanced compared to that of an individual heavy atom with the same absorption cross-section. This enhancement is driven by ultrafast charge transfer within the molecule, which refills the core holes that are created in the heavy atom, providing further targets for inner-shell ionization and resulting in the emission of more than 50 electrons during the X-ray pulse. Our results demonstrate that efficient modelling of X-ray-driven processes in complex systems at ultrahigh intensities is feasible.
Femtosecond response of polyatomic molecules to ultra-intense hard X-rays
Rudenko, A.; Inhester, L.; Hanasaki, K.; ...
2017-05-31
We report x-ray free-electron lasers enable the investigation of the structure and dynamics of diverse systems, including atoms, molecules, nanocrystals and single bioparticles, under extreme conditions. Many imaging applications that target biological systems and complex materials use hard X-ray pulses with extremely high peak intensities (exceeding 10 20 watts per square centimetre). However, fundamental investigations have focused mainly on the individual response of atoms and small molecules using soft X-rays with much lower intensities. Studies with intense X-ray pulses have shown that irradiated atoms reach a very high degree of ionization, owing to multiphoton absorption, which in a heteronuclear molecularmore » system occurs predominantly locally on a heavy atom (provided that the absorption cross-section of the heavy atom is considerably larger than those of its neighbours) and is followed by efficient redistribution of the induced charge. In serial femtosecond crystallography of biological objects—an application of X-ray free-electron lasers that greatly enhances our ability to determine protein structure—the ionization of heavy atoms increases the local radiation damage that is seen in the diffraction patterns of these objects and has been suggested as a way of phasing the diffraction data. On the basis of experiments using either soft or less-intense hard X-rays, it is thought that the induced charge and associated radiation damage of atoms in polyatomic molecules can be inferred from the charge that is induced in an isolated atom under otherwise comparable irradiation conditions. Here we show that the femtosecond response of small polyatomic molecules that contain one heavy atom to ultra-intense (with intensities approaching 10 20 watts per square centimetre), hard (with photon energies of 8.3 kiloelectronvolts) X-ray pulses is qualitatively different: our experimental and modelling results establish that, under these conditions, the ionization of a molecule is considerably enhanced compared to that of an individual heavy atom with the same absorption cross-section. This enhancement is driven by ultrafast charge transfer within the molecule, which refills the core holes that are created in the heavy atom, providing further targets for inner-shell ionization and resulting in the emission of more than 50 electrons during the X-ray pulse. Fnally, our results demonstrate that efficient modelling of X-ray-driven processes in complex systems at ultrahigh intensities is feasible.« less
Femtosecond response of polyatomic molecules to ultra-intense hard X-rays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rudenko, A.; Inhester, L.; Hanasaki, K.
We report x-ray free-electron lasers enable the investigation of the structure and dynamics of diverse systems, including atoms, molecules, nanocrystals and single bioparticles, under extreme conditions. Many imaging applications that target biological systems and complex materials use hard X-ray pulses with extremely high peak intensities (exceeding 10 20 watts per square centimetre). However, fundamental investigations have focused mainly on the individual response of atoms and small molecules using soft X-rays with much lower intensities. Studies with intense X-ray pulses have shown that irradiated atoms reach a very high degree of ionization, owing to multiphoton absorption, which in a heteronuclear molecularmore » system occurs predominantly locally on a heavy atom (provided that the absorption cross-section of the heavy atom is considerably larger than those of its neighbours) and is followed by efficient redistribution of the induced charge. In serial femtosecond crystallography of biological objects—an application of X-ray free-electron lasers that greatly enhances our ability to determine protein structure—the ionization of heavy atoms increases the local radiation damage that is seen in the diffraction patterns of these objects and has been suggested as a way of phasing the diffraction data. On the basis of experiments using either soft or less-intense hard X-rays, it is thought that the induced charge and associated radiation damage of atoms in polyatomic molecules can be inferred from the charge that is induced in an isolated atom under otherwise comparable irradiation conditions. Here we show that the femtosecond response of small polyatomic molecules that contain one heavy atom to ultra-intense (with intensities approaching 10 20 watts per square centimetre), hard (with photon energies of 8.3 kiloelectronvolts) X-ray pulses is qualitatively different: our experimental and modelling results establish that, under these conditions, the ionization of a molecule is considerably enhanced compared to that of an individual heavy atom with the same absorption cross-section. This enhancement is driven by ultrafast charge transfer within the molecule, which refills the core holes that are created in the heavy atom, providing further targets for inner-shell ionization and resulting in the emission of more than 50 electrons during the X-ray pulse. Fnally, our results demonstrate that efficient modelling of X-ray-driven processes in complex systems at ultrahigh intensities is feasible.« less
Tactical Missile Conceptual Design,
1980-09-01
Temperature ..... ........... 110 a. Example I .... ................. 111 6 Page b. Example II ... ............... .. 112 6. Simple IR System...meet a current threat. An example of this might be an advance in material science, which allows higher inlet turbine temperatures for a turbojet...Pmin = k TO B n N 0)min Boltzmans constant is k = 1.38 x 10- 2 3 joule/ k. The value of kT0 at room temperature is 4 x 10 - 21 watt/cps of bandwidth
20 CFR 10.310 - What are the basic rules for obtaining medical care?
Code of Federal Regulations, 2014 CFR
2014-04-01
... physicians' assistants, nurse practitioners and physical therapists may also provide authorized services for... § 10.800. OWCP may also utilize the services of a field nurse to facilitate and coordinate medical care...
20 CFR 10.310 - What are the basic rules for obtaining medical care?
Code of Federal Regulations, 2013 CFR
2013-04-01
... physicians' assistants, nurse practitioners and physical therapists may also provide authorized services for... § 10.800. OWCP may also utilize the services of a field nurse to facilitate and coordinate medical care...
20 CFR 10.310 - What are the basic rules for obtaining medical care?
Code of Federal Regulations, 2012 CFR
2012-04-01
... physicians' assistants, nurse practitioners and physical therapists may also provide authorized services for... § 10.800. OWCP may also utilize the services of a field nurse to facilitate and coordinate medical care...
[Initial experience with a new blood pump].
Margreiter, R; Schwab, W; Klima, G; Koller, J; Baum, M; Dietrich, H; Hager, J; Königsrainer, A
1990-12-01
A new type of blood pump was tested in calves for 6 hours. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotating on an eccentric shaft, describes a trochoidal path, thus creating a gap seal, the gap measuring a constant 10-35 microns. The pump is driven by a watercooled DC motor. For right ventricular assist, a cannula is inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assists. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 31 at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hours, and returned to 16 mg/dl after 6 hours. From these preliminary results it is concluded that this new rotary blood pump may be suitable as a circulatory assist device.
INTRACORPOREAL HEAT DISSIPATION FROM A RADIOISOTOPE-POWERED ARTIFICIAL HEART.
Huffman, Fred N.; Hagen, Kenneth G.; Whalen, Robert L.; Fuqua, John M.; Norman, John C.
1974-01-01
The feasibility of radioisotope-fueled circulatory support systems depends on the ability of the body to dissipate the reject heat from the power source driving the blood pump as well as to tolerate chronic intracorporeal radiation. Our studies have focused on the use of the circulating blood as a heat sink. Initial in vivo heat transfer studies utilized straight tube heat exchangers (electrically and radioisotope energized) to replace a segment of the descending aorta. More recent studies have used a left ventricular assist pump as a blood-cooled heat exchanger. This approach minimizes trauma, does not increase the area of prosthetic interface with the blood, and minimizes system volume. Heat rejected from the thermal engine (vapor or gas cycle) is transported from the nuclear power source in the abdomen to the pump in the thoracic cavity via hydraulic lines. Adjacent tissue is protected from the fuel capsule temperature (900 to 1200 degrees F) by vacuum foil insulation and polyurethane foam. The in vivo thermal management problems have been studied using a simulated thermal system (STS) which approximates the heat rejection and thermal transport mechanisms of the nuclear circulatory support systems under development by NHLI. Electric heaters simulate the reject heat from the thermal engines. These studies have been essential in establishing the location, suspension, surgical procedures, and postoperative care for implanting prototype nuclear heart assist systems in calves. The pump has a thermal impedance of 0.12 degrees C/watt. Analysis of the STS data in terms of an electrical analog model implies a heat transfer coefficient of 4.7 x 10(-3) watt/cm(2) degrees C in the abdomen compared to a value of 14.9 x 10(-3) watt/cm(2) degrees C from the heat exchanger plenum into the diaphragm.
Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling.
Shen, Guangping; Zhang, Songning; Bennett, Hunter J; Martin, James C; Crouter, Scott E; Fitzhugh, Eugene C
2018-06-01
Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling.
Radioisotope Stirling Generator Options for Pluto Fast Flyby Mission
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schock, Alfred
The preceding paper described conceptual designs and analytical results for five Radioisotope Thermoelectric Generator (RTG) options for the Pluto Fast Flyby (PFF) mission, and the present paper describes three Radioisotope Stirling Generator (RSG) options for the same mission. The RSG options are based on essentially the same radioisotope heat source modules used in previously flown RTGs and on designs and analyses of a 75-watt free-piston Stirling engine produced by Mechanical Technology Incorporated (MTI) for NASA's Lewis Research Center. The integrated system design options presented were generated in a Fairchild Space study sponsored by the Department of Energy's Office of Specialmore » Applications, in support of ongoing PFF mission and spacecraft studies that the Jet Propulsion Laboratory (JPL) is conducting for the National Aeronautics and Space Administration (NASA). That study's NASA-directed goal is to reduce the spacecraft mass from its baseline value of 166 kg to ~110 kg, which implies a mass goal of less than 10 kg for a power source able to deliver 69 watts(e) at the end of the 9.2-year mission. In general, the Stirling options were found to be lighter than the thermoelectric options described in the preceding paper. But they are less mature, requiring more development, and entailing greater programmatic risk. The Stirling power system mass ranged from 7.3 kg (well below the 10-kg goal) for a non-redundant system to 11.3 kg for a redundant system able to maintain full power if one of its engines fails. In fact, the latter system could deliver as much as 115 watts(e) if desired by the mission planners. There are 2 copies in the file.« less
Seasonal thermoregulatory responses in mammals.
Lovegrove, Barry G
2005-05-01
This study examined the proportional seasonal winter adjustments of total and mass-specific basal power (watts and watts g-1, respectively), thermal conductance (watts g-1 degrees C-1), non-shivering thermogenesis capacity (ratio of NST/basal power), body temperature ( degrees C), and body mass (g) of mammals. The responses are best summarized for three different body size classes; small mammals (<100 g), intermediate-sized mammals (0.1-10 kg), and large mammals (>10 kg). The principal adjustments of the small mammals center on energy conservation, especially the Dehnel Effect, the winter reduction in body size of as much as 50%, accompanied by reductions in mass-specific basal power. On average, these reductions reduce the total basal power approximately in direct proportion to the mass reductions. Reductions in mass-specific basal power are matched by concomitant reductions in conductance to maintain the setpoint body temperature during winter. The overall thermoregulatory adjustments in small mammals serve to (a) lower overall winter power consumption, (b) maintain the setpoint body temperature, and (c) lower the lower critical limit of thermoneutrality and hence thermoregulatory costs. In intermediate-size mammals, the seasonal response is centered more on increasing thermogenic capacity by increasing basal power and NST capacity, accompanied by predictable and large reductions in conductance. The Dehnel effect is negligible. Very large mammals undergo the largest reductions in total and mass-specific basal power and conductance. However, there are too few data to resolve whether the reductions in total basal power can be attributed to the Dehnel effect, because the moderate decreases in body mass may also be caused by nutritional stress. Apart from the seasonal changes in basal power, these observations are consistent with the predictions of Heldmaier's seasonal acclimatization model.
Alexander, Marcalee S; New, Peter W; Biering-Sørensen, Fin; Courtois, Frederique; Popolo, Giulio Del; Elliott, Stacy; Kiekens, Carlotte; Vogel, Lawrence; Previnaire, Jean G
2017-01-01
Data set review and modification. To describe modifications in the International Spinal Cord Injury (SCI) Male Sexual Function Basic Data Set Version 2.0 and the International SCI Female Sexual and Reproductive Function Basic Data Set Version 2.0. International expert work group using on line communication. An international team of experts was compiled to review and revise the International SCI Male Sexual Function and Female Sexual and Reproductive Function Basic Data Sets Version 1.0. The group adapted Version 1.0 based upon review of published research, suggestions from concerned individuals and on line work group consensus. The revised data sets were then posted on the International Spinal Cord Society (ISCoS) and American Spinal Injury Association (ASIA) websites for 2 months for review. Subsequently, the data sets were approved by the ISCoS Scientific and Executive Committees and ASIA board of directors. The data sets were modified to a self-report format. They were reviewed for appropriateness for the pediatric age group and adapted to include a new variable to address the issue of sexual orientation. A clarification of the difference between the data sets and the autonomic standards was also developed. Sexuality is a continuously evolving topic. Modifications were needed to address this topic in a comprehensive fashion. It is recommended that Version 2.0 of these data sets are used for ongoing documentation of sexual status in the medical record and for documentation of sexual concerns during on-going research.
Biomechanical energy harvesting: generating electricity during walking with minimal user effort.
Donelan, J M; Li, Q; Naing, V; Hoffer, J A; Weber, D J; Kuo, A D
2008-02-08
We have developed a biomechanical energy harvester that generates electricity during human walking with little extra effort. Unlike conventional human-powered generators that use positive muscle work, our technology assists muscles in performing negative work, analogous to regenerative braking in hybrid cars, where energy normally dissipated during braking drives a generator instead. The energy harvester mounts at the knee and selectively engages power generation at the end of the swing phase, thus assisting deceleration of the joint. Test subjects walking with one device on each leg produced an average of 5 watts of electricity, which is about 10 times that of shoe-mounted devices. The cost of harvesting-the additional metabolic power required to produce 1 watt of electricity-is less than one-eighth of that for conventional human power generation. Producing substantial electricity with little extra effort makes this method well-suited for charging powered prosthetic limbs and other portable medical devices.
Red palm oil production by microwave irradiation
NASA Astrophysics Data System (ADS)
Sarah, M.; Widyastuti, S.; Ningsih, D.
2018-02-01
Preliminary study of red palm oil (RPO) production from palm fruitlets by microwave irradiation carried out in domestic microwave oven equipped with thermocouple. The various mass of fruitlets (800, 900 and 1000 g) were heated for 10-18 minutes with 2 minutes interval and microwave power of 400, 560 and 800 Watt respectively. Heated fruitlets were pressed by hydraulic presser to obtain RPO. This study observed heating time parameter was more crucial to RPO quality rather than temperature. Prolonged heating degraded carotenoids in the fruitlets during heating process yielded less carotenoids content in the palm oil. The best time and microwave power combination to produce RPO in this study was 14 minutes and 800 Watt respectively which yielded 11.67% RPO with 1.27% FFA content and carotenoids concentration of 1219.37 ppm. Overall, RPO production by microwave irradiation proceeded faster as compared to conventional process.
L. V. Al'tshuler, and High Energy Density Research
NASA Astrophysics Data System (ADS)
Gibson, Carl H.; Krikorian, Nerses H.; Keeler, R. Norris
2012-03-01
Knowledge of high energy densities critical to cosmology and astrophysics was achieved and exchanged among a very few scientists at a time when science was even more constrained by political considerations that it is today. Resources for the early studies necessarily involved atomic weaponry. A history of L. V. Al'tshuler and some others in his science is given in cosmological context. In the beginning of cosmology and the Universe, negative Fortov-Planck1 pressures c7h-1G-2 of 4.6 10115 Pa are overcome by inertial-vortex anti-gravity (dark energy) pressures to achieve a turbulent big bang and the first turbulent combustion with power 1066 watts at the Kolmogorov-Planck scale 10-35 meters. The big bang event ceased when negative- pressure gluon-viscous-forces extracted 10100 kg of mass-energy from the vacuum to produce the observed fossil vorticity turbulence Universe and its inflation with power 10145 watts.
Details of the 1998 Watt Balance Experiment Determining the Planck Constant
Steiner, Richard; Newell, David; Williams, Edwin
2005-01-01
The National Institute of Standards and Technology (NIST) watt balance experiment completed a determination of Planck constant in 1998 with a relative standard uncertainty of 87 × 10−9 (k = 1), concurrently with an upper limit on the drift rate of the SI kilogram mass standard. A number of other fundamental physical constants with uncertainties dominated by this result are also calculated. This paper focuses on the details of the balance apparatus, the measurement and control procedures, and the reference calibrations. The alignment procedures are also described, as is a novel mutual inductance measurement procedure. The analysis summary discusses the data noise sources and estimates for the Type B uncertainty contributions to the uncertainty budget. Much of this detail, some historical progression, and a few recent findings have not been included in previous papers reporting the results of this experiment. PMID:27308100
Design and test of a pumped two-phase mounting plate. [for spacecraft thermal control systems
NASA Technical Reports Server (NTRS)
Grote, M. G.; Swanson, T. D.
1985-01-01
The design, fabrication, and testing of the full-scale development unit of a pumped two-phase mounting plate (TPMP) used in advanced two-phase spacecraft thermal control systems are described. The mounting plate is tested with R-11 in the evaporator mode for total heat loads of over 3000 watts and local heat fluxes over 4 W/sq cm, and in the condenser mode with condenser loads from 60 to 400 watts and inlet qualities from 8 to 94 percent. The calculated heat-transfer coefficients are between 0.66 and 1.0 W/sq cm/C and are nearly independent of the flow rate and heat load except at very low heat loads. It is shown that the TPMP can be run with inlet conditions down to 22 C subcooling without any significant gradients in the plate and that it performs well with nonuniform heat fluxes.
Laser damage tests on InSb photodiodes at 1.064 micron and 0.532 micron
NASA Technical Reports Server (NTRS)
Bearman, G. H.; Staller, C.; Mahoney, C.
1992-01-01
InSb photodiodes were examined for performance degradation after pulsed laser illumination at 0.532 micron and 1.064 micron. Incident laser powers ranged from 6 x 10 exp-18 micron-watts to 16 micron-watts in a 50 pm diameter spot. Dark current and spectral response were both measured before and after illumination. Dark current measurements were taken with the diode blanked off and viewing only 77 K surfaces. Long term stability tests demonstrated that the blackbody did not exhibit long term drifts. Other tests showed that room temperature variations did not affect the diode signal chain or the digitization electronics used in data acquisition. Results of the experiment show that the diodes did not exhibit changes in dark current or spectral response performance as a result of the laser illumination. A typical change in diode spectral response (before/after laser exposure) was about 0.2 percent +/- 0.2 percent.
Realistic Specific Power Expectations for Advanced Radioisotope Power Systems
NASA Technical Reports Server (NTRS)
Mason, Lee S.
2006-01-01
Radioisotope Power Systems (RPS) are being considered for a wide range of future NASA space science and exploration missions. Generally, RPS offer the advantages of high reliability, long life, and predictable power production regardless of operating environment. Previous RPS, in the form of Radioisotope Thermoelectric Generators (RTG), have been used successfully on many NASA missions including Apollo, Viking, Voyager, and Galileo. NASA is currently evaluating design options for the next generation of RPS. Of particular interest is the use of advanced, higher efficiency power conversion to replace the previous thermoelectric devices. Higher efficiency reduces the quantity of radioisotope fuel and potentially improves the RPS specific power (watts per kilogram). Power conversion options include Segmented Thermoelectric (STE), Stirling, Brayton, and Thermophotovoltaic (TPV). This paper offers an analysis of the advanced 100 watt-class RPS options and provides credible projections for specific power. Based on the analysis presented, RPS specific power values greater than 10 W/kg appear unlikely.
GaAs MMIC elements in phased-array antennas
NASA Technical Reports Server (NTRS)
Leonard, Regis F.
1988-01-01
Over the last six years NASA Lewis Research Center has carried out a program aimed at the development of advanced monolithic microwave integrated circuit technology, principally for use in phased-array antenna applications. Arising out of the Advanced Communications Technology Satellite (ACTS) program, the initial targets of the program were chips which operated at 30 and 20 GHz. Included in this group of activities were monolithic power modules with an output of 2 watts at GHz, variable phase shifters at both 20 and 30 GHz, low noise technology at 30 GHz, and a fully integrated (phase shifter, variable gain amplifier, power amplifier) transmit module at 20 GHz. Subsequent developments are centered on NASA mission requirements, particularly Space Station communications systems and deep space data communications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... power must not exceed 2 watts (ERP): Channels 1-8 paired with Channels 961-968, and Channels 949-958... 2 watts (ERP): Channels 9-12 paired with Channels 969-972 and Channels 959-960 paired with Channels...
Solid state Impatt Amplifiers performance data
DOT National Transportation Integrated Search
1973-12-01
Evaluation data on an 8-watt and a 16-watt Impatt Amplifier represented to concisely describe the performance of these amplifiers. The data include component specifications and photographs, TSC test set-up configuration, amplitude and phase character...
High-power diode laser bars as pump sources for fiber lasers and amplifiers (Invited Paper)
NASA Astrophysics Data System (ADS)
Bonati, G.; Hennig, P.; Wolff, D.; Voelckel, H.; Gabler, T.; Krause, U.; T'nnermann, A.; Reich, M.; Limpert, J.; Werner, E.; Liem, A.
2005-04-01
Fiber lasers are pumped by fibercoupled, multimode single chip devices at 915nm. That"s what everybody assumes when asked for the type of fiber laser pumps and it was like this for many years. Coming up as an amplifier for telecom applications, the amount of pump power needed was in the range of several watts. Highest pump powers for a limited market entered the ten watts range. This is a range of power that can be covered by highly reliable multimode chips, that have to survive up to 25 years, e.g. in submarine applications. With fiber lasers entering the power range and the application fields of rod and thin disc lasers, the amount of pump power needed raised into the area of several hundred watts. In this area of pump power, usually bar based pumps are used. This is due to the much higher cost pressure of the industrial customers compared to telecom customers. We expect more then 70% of all industrial systems to be pumped by diode laser bars. Predictions that bar based pumps survive for just a thousand hours in cw-operation and fractions of this if pulsed are wrong. Bar based pumps have to perform on full power for 10.000h on Micro channel heat sinks and 20.000h on passive heatsinks in industrial applications, and they do. We will show a variety of data, "real" long time tests and statistics from the JENOPTIK Laserdiode as well as data of thousands of bars in the field, showing that bar based pumps are not just well suitable for industrial applications on high power levels, but even showing benefits compared to chip based pumps. And it"s reasonable, that the same objectives of cost effectiveness, power and lifetime apply as well to thin disc, rod and slab lasers as to fiber lasers. Due to the pumping of fiber lasers, examples will be shown, how to utilize bars for high brightness fiber coupling. In this area, the automation is on its way to reduce the costs on the fibercoupling, similar to what had been done in the single chip business. All these efforts are part of the JENOPTIK Laserdiode"s LongLifeTechnologie.
CO2 laser drives extreme ultraviolet nano-lithography — second life of mature laser technology
NASA Astrophysics Data System (ADS)
Nowak, K. M.; Ohta, T.; Suganuma, T.; Fujimoto, J.; Mizoguchi, H.; Sumitani, A.; Endo, A.
2013-12-01
It was shown both theoretically and experimentally that nanosecond order laser pulses at 10.6 micron wavelength were superior for driving the Sn plasma extreme ultraviolet (EUV) source for nano-lithography for the reasons of higher conversion efficiency, lower production of debris and higher average power levels obtainable in CO2 media without serious problems of beam distortions and nonlinear effects occurring in competing solid-state lasers at high intensities. The renewed interest in such pulse format, wavelength, repetition rates in excess of 50 kHz and average power levels in excess of 18 kiloWatt has sparked new opportunities for a matured multi-kiloWatt CO2 laser technology. The power demand of EUV source could be only satisfied by a Master-Oscillator-Power-Amplifier system configuration, leading to a development of a new type of hybrid pulsed CO2 laser employing a whole spectrum of CO2 technology, such as fast flow systems and diffusion-cooled planar waveguide lasers, and relatively recent quantum cascade lasers. In this paper we review briefly the history of relevant pulsed CO2 laser technology and the requirements for multi-kiloWatt CO2 laser, intended for the laser-produced plasma EUV source, and present our recent advances, such as novel solid-state seeded master oscillator and efficient multi-pass amplifiers built on planar waveguide CO2 lasers.
Measuring the greenhouse effect and radiative forcing through the atmosphere
NASA Astrophysics Data System (ADS)
Philipona, Rolf; Kräuchi, Andreas; Brocard, Emmanuel
2013-04-01
In spite of a large body of existing measurements of incoming shortwave solar radiation and outgoing longwave terrestrial radiation at the Earth's surface and at the top of the atmosphere, there are few observations documenting how radiation profiles change through the atmosphere - information that is necessary to fully quantify the greenhouse effect of the Earth's atmosphere. Using weather balloons and specific radiometer equipped radiosondes, we continuously measured shortwave and longwave radiation fluxes from the surface of the Earth up to altitudes of 35 kilometers in the upper stratosphere. Comparing radiation profiles from night measurements with different amounts of water vapor, we show evidence of large greenhouse forcing. We show, that under cloud free conditions, water vapor increases with Clausius-Clapeyron ( 7% / K), and longwave downward radiation at the surface increases by 8 Watts per square meter per Kelvin. The longwave net radiation however, shows a positive increase (downward) of 2.4 Watts per square meter and Kelvin at the surface, which decreases with height and shows a similar but negative increase (upward) at the tropopause. Hence, increased tropospheric water vapor increases longwave net radiation towards the ground and towards space, and produces a heating of 0.42 Kelvin per Watt per square meter at the surface. References: Philipona et al., 2012: Solar and thermal radiation profiles and radiative forcing measured through the atmosphere. Geophys. Res. Lett., 39, L13806, doi: 10.1029/2012GL052087.
High-power visible laser effect on a Boston Micromachines' MEMS deformable mirror
NASA Astrophysics Data System (ADS)
Norton, Andrew; Gavel, Donald; Dillon, Daren; Cornelissen, Steven
2010-07-01
Continuous-facesheet and segmented Boston Micromachines Corporations' (BMC) Micro-Electrical Mechanical Systems (MEMS) Deformable Mirrors (DM) have been tested for their response to high-power visible-wavelength laser light. The deformable mirrors, coated with either protected silver or bare aluminum, were subjected to a maximum of 2 Watt laser-light at a wavelength of 532 nanometers. The laser light was incident on a ~ 3.5×3.5 cm area for time periods from minutes to 7 continuous hours. Spot heating from the laser-light is measured to induce a local bulge in the surface of each DM. For the aluminum-coated continuous facesheet DM, the induced spot heating changes the surface figure by 16 nm rms. The silver-coated continuous-facesheet and segmented (spatial light modulator) DMs experience a 6 and 8 nm surface rms change in surface quality with the laser at 2 Watts. For spatial frequencies less than the actuator spacing (300 mm), the laser induced surface bulge is shown to be removable, as the DMs continued to be fully functional during and after their exposure. Over the full 10 mm aperture one could expect the same results with a 15 Watt laser guide star (LGS). These results are very promising for use of the MEMS DM to pre-correct the outgoing laser light in the Laboratory for Adaptive Optics' (LAO) laser uplink application.
Response of end tidal CO2 pressure to impulse exercise.
Yano, T; Afroundeh, R; Yamanak, R; Arimitsu, T; Lian, C-S; Shirkawa, K; Yunoki, T
2014-03-01
The purpose of the present study was to examine how end tidal CO(2) pressure (PETCO(2)) is controlled in impulse exercise. After pre-exercise at 25 watts for 5 min, impulse exercise for 10 sec with 200 watts followed by post exercise at 25 watts was performed. Ventilation (VE) significantly increased until the end of impulse exercise and significantly re-increased after a sudden decrease. Heart rate (HR) significantly increased until the end of impulse exercise and then decreased to the pre-exercise level. PETCO(2) remained constant during impulse exercise. PETCO(2) significantly increased momentarily after impulse exercise and then significantly decreased to the pre-exercise level. PETCO(2) showed oscillation. The average peak frequency of power spectral density in PETCO(2) appeared at 0.0078 Hz. Cross correlations were obtained after impulse exercise. The peak cross correlations between VE and PETCO(2), HR and PETCO(2), and VE and HR were 0.834 with a time delay of -7 sec, 0.813 with a time delay of 7 sec and 0.701 with a time delay of -15 sec, respectively. We demonstrated that PETCO(2) homeodynamics was interactively maintained by PETCO(2) itself, CO(2) transportation (product of cardiac output and mixed venous CO(2) content) into the lungs by heart pumping and CO(2) elimination by ventilation, and it oscillates as a result of their interactions.
Dynamics of Radiation and Atoms in Ultrahigh Intensity Laser Fields
2013-12-31
Rob Mitchell, N. Ekanayake, A. Watts, S. White , Rob Sauer, L. Howard, M. Videtto, C. Mancuso, S. Wells, T. Stanev, B. Wen, M. Decamp, B. Walker, Sasi...Chen, Z. Bond, A. Loether, L. E. Howard, Y. Gao, S. LeMar, S. White , A. Watts, B. C. Walker, M. F. DeCamp. Reconstructing longitudinal strain pulses...Ekanayake, A.M. Watts, S.L. White , Rob Sauer, L.E. Howard, M. Videtto, C. Mancuso, S.J. Wells, T. Stanev, B.L. Wen, M.F. Decamp, and B.C. Walker. Ionization
ERIC Educational Resources Information Center
Lozano, Aliber; Watt, Karen M.; Huerta, Jeffery
2009-01-01
This study assessed the differences in educational aspirations and educational anticipations between four groups (AVID, GEAR UP, AVID/GEAR UP, and Control) of high school seniors who participated in a previous study as 10th graders (Watt, Huerta, & Lozano, 2007). It also measured whether any change in aspirations and anticipations occurred…
Ojima, Yasukuni; Nawata, Kouji; Omatsu, Takashige
2005-10-31
We have produced a high beam quality pico-second laser based on a continuous-wave diode pumped Nd:YVO4 slab amplifier with a photorefractive phase conjugate mirror. 12.8W diffraction-limited output with a pulse width of 8.7ps was obtained.
47 CFR 76.616 - Operation near certain aeronautical and marine emergency radio frequencies.
Code of Federal Regulations, 2012 CFR
2012-10-01
... (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical Standards § 76... of carriers or other signal components capable of delivering peak power levels equal to or greater than 10−5 watts at any point in a cable television system is prohibited within 100 kHz of the frequency...
47 CFR 76.616 - Operation near certain aeronautical and marine emergency radio frequencies.
Code of Federal Regulations, 2014 CFR
2014-10-01
... (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical Standards § 76... of carriers or other signal components capable of delivering peak power levels equal to or greater than 10−5 watts at any point in a cable television system is prohibited within 100 kHz of the frequency...
Development of a solar charged laboratory bench power supply
NASA Astrophysics Data System (ADS)
Ayara, W. A.; Omotosho, T. V.; Usikalu, M. R.; Singh, M. S. J.; Suparta, W.
2017-05-01
This product is an improvement on available DC laboratory bench power supply. It is capable of delivering low voltage Alternating Current (AC) and Direct Current (DC) to carry out basic laboratory experiment for both secondary schools and also at higher education institutions. The power supply is capable of delivering fixed DC voltages of 5V, 9V, 12V, variable voltage of between 1.25-30V and a 12V AC voltage. Also Incorporated is a USB port that allows for charging cell phones and other mobile devices, and a dedicated 12V DC output to power 5-7 Watt LED bulb to provide illumination in the laboratory for the instructor who may need to work at night in the absence of utility power.
Comfort studies of rail passengers
Nicol, J. F.; Doré, C.; Weiner, J. S.; Lee, D. E.; Prestidge, S. P.; Andrews, M. J.
1973-01-01
Nicol, J. F., Doré, C., Weiner, J. S., Lee, D. E., Prestidge, S. P., and Andrews, M. J. (1973).British Journal of Industrial Medicine,30, 325-334. Comfort studies of rail passengers. A short series of trials is described in which a specimen car of the new High Density Rolling Stock was laden with passengers at different densities and under different environmental constraints, designed to simulate `shut-down' conditions. The results suggest that the limit for comfort, 21·8°C corrected effective temperature (CET), proposed by Bell and Watts (1971) is reasonable but that temperatures some 3 or 4°C higher can be tolerated without undue discomfort. The physiological limit for safety recommended by Bell and Watts is a CET of 30·6°C. This will be reached in less than 20 minutes if there is a power failure in warm conditions in crowded trains. An undesirable, possibly dangerous, level of discomfort will be experienced by passengers in ventilated but crowded trains after 30 minutes. In any case it is recommended that the globe temperature in a carriage should not exceed 30°C. Images PMID:4753715
Power Generator with Thermo-Differential Modules
NASA Technical Reports Server (NTRS)
Saiz, John R.; Nguyen, James
2010-01-01
A thermoelectric power generator consists of an oven box and a solar cooker/solar reflector unit. The solar reflector concentrates sunlight into heat and transfers the heat into the oven box via a heat pipe. The oven box unit is surrounded by five thermoelectric modules and is located at the bottom end of the solar reflector. When the heat is pumped into one side of the thermoelectric module and ejected from the opposite side at ambient temperatures, an electrical current is produced. Typical temperature accumulation in the solar reflector is approximately 200 C (392 F). The heat pipe then transfers heat into the oven box with a loss of about 40 percent. At the ambient temperature of about 20 C (68 F), the temperature differential is about 100 C (180 F) apart. Each thermoelectric module, generates about 6 watts of power. One oven box with five thermoelectric modules produces about 30 watts. The system provides power for unattended instruments in remote areas, such as space colonies and space vehicles, and in polar and other remote regions on Earth.
Coil motion effects in watt balances: a theoretical check
NASA Astrophysics Data System (ADS)
Li, Shisong; Schlamminger, Stephan; Haddad, Darine; Seifert, Frank; Chao, Leon; Pratt, Jon R.
2016-04-01
A watt balance is a precision apparatus for the measurement of the Planck constant that has been proposed as a primary method for realizing the unit of mass in a revised International System of Units. In contrast to an ampere balance, which was historically used to realize the unit of current in terms of the kilogram, the watt balance relates electrical and mechanical units through a virtual power measurement and has far greater precision. However, because the virtual power measurement requires the execution of a prescribed motion of a coil in a fixed magnetic field, systematic errors introduced by horizontal and rotational deviations of the coil from its prescribed path will compromise the accuracy. We model these potential errors using an analysis that accounts for the fringing field in the magnet, creating a framework for assessing the impact of this class of errors on the uncertainty of watt balance results.
The human, primate and rabbit ultraviolet action spectra
NASA Technical Reports Server (NTRS)
Pitts, D. G.; Gibbons, W. D.
1972-01-01
A 5000 watt xenon-mercury high pressure lamp was used to produce a continuous ultraviolet spectrum. Human and animal exposures were made to establish the photokeratitis threshold and abiotic action spectrum. The lower limit of the abiotic action spectrum was 220 nm while the upper limit was 310 nm. The radiant exposure threshold at 270 nm was 0.005 watts/sq cm for the rabbit, 0.004 watts/sq cm for the primate, and 0.004 watts/ sq cm for the human. The rabbit curve was bi-peaked with minimums at 220 nm, 240 nm and 270 nm. The primate curve was tri-peaked with minimums at 220 nm, 240 nm and 270 nm. The human data showed a rather shallow curve with a minimum at 270 nm. Formulas and calculations are given to predict minimum exposure times for ocular damage to man in outer space, to establish valid safety criteria, and to establish protective design criteria.
Test results of a ten cell bipolar nickel-hydrogen battery
NASA Technical Reports Server (NTRS)
Cataldo, R. L.
1983-01-01
A ten cell bipolar nickel hydrogen 6.5 ampere-hour battery demonstrated over 2000 low Earth orbit cycles at an 80 percent depth-of-discharge. Charge/discharge cyclic ampere-hour and watt-hour efficiencies of 88 and 76 percent, respectively, observed. Peak power capability was determined at 1.1 kW. A 10C discharge rate yields 83 percent of the nominal stark capacity to the 1.0 volt cut off in just under 6 minutes.
AGT M235T and ACE ID polymorphisms and exercise blood pressure in the HERITAGE Family Study.
Rankinen, T; Gagnon, J; Pérusse, L; Chagnon, Y C; Rice, T; Leon, A S; Skinner, J S; Wilmore, J H; Rao, D C; Bouchard, C
2000-07-01
We investigated the association between angiotensinogen (AGT) and angiotensin-converting enzyme (ACE) gene polymorphisms and exercise training responses of resting and exercise blood pressure (BP). BP at rest and during submaximal (50 watts) and maximal exercise tests was measured before and after 20 wk of endurance training in 476 sedentary normotensive Caucasian subjects from 99 families. AGT M235T and ACE insertion/deletion polymorphisms were typed with PCR-based methods. Men carrying the AGT MM and MT genotypes showed 3. 7 +/- 0.6 and 3.2 +/- 0.5 (SE) mmHg reductions, respectively, in diastolic BP at 50 watts (DBP(50)), whereas, in the TT homozygotes, the decrease was 0.4 +/- 1.0 mmHg (P = 0.016 for trend, adjusted for age, body mass index, and baseline DBP(50)). Men with the ACE DD genotype showed a slightly greater decrease in DBP(50) (4.4 +/- 0.6 mmHg) than the II and ID genotypes (2.8 +/- 0.7 and 2.4 +/- 0.5 mmHg, respectively, P = 0.050). Furthermore, a significant (P = 0.022) interaction effect between the AGT and ACE genes was noted for DBP(50); the AGT TT homozygotes carrying the ACE D allele showed no response to training. Men with the AGT TT genotype had greater (P = 0.007) diastolic BP (DBP) response to acute maximal exercise at baseline. However, the difference disappeared after the training period. No associations were found in women. These data suggest that, in men, the genetic variation in the AGT locus modifies the responsiveness of submaximal exercise DBP to endurance training, and interactions between the AGT and ACE loci can alter this response.
Tsuyumu, M; Verasques, G; Yamazaki, S; Kuroiwa, T; Suzuki, R; Takei, H; Suzuki, K; Inaba, Y
1985-04-01
The CO2 laser is useful for cutting and vaporization but not for coagulation and hemostasis. On the contrary, YAG laser is effective for coagulation and hemostasis but not for cutting. The purpose of this study is to examine the effect of the exposure of combined, coaxial CO2 and YAG laser on the animal brain to supplement the advantages and draw-backs of each other. To compare these results, each of non-combined pulse wave form CO2 and YAG lasers was employed separately. The lasers in this study were pulse wave form CO2 and YAG lasers, employed separately or simultaneously using 130 YZ of Nihon Infrared Industries Company. Japanese white rabbits were anesthetized with pentobarbital. Fronto-parietal burr holes were made, the dura was removed and then Evans blue solution was injected intravenously. The lasers were employed to the cerebral cortex without great vessels using a micromanipulator attached to the operative microscope with a distance of 30 cm. The spot size was 700 mu for CO2 laser and 1200 mu for YAG laser. The first experiment was to see the effect of nine combinations of simultaneous coaxial CO2 of 2, 4 and 8 watts and YAG lasers of 10, 20 and 40 watts, 1 sec on the brain. In the second experiment, also combining two lasers, the exposure time of YAG laser was elongated from 1 or 2 seconds into 2 or 4 seconds and the arrangement of powers was the same as that of the first experiment. The lesions were thus made in 18 different conditions.(ABSTRACT TRUNCATED AT 250 WORDS)
Martinez, Alexa; Roberts, Glenn; Garzarella, Katherine; Lutz, Michael; Caswell, Michael
2013-04-01
The purpose of these clinical trials was to determine if 300 W and 150 W xenon arc solar simulators (SSs) deliver the same sun protection factor (SPF) and UVA protection factor (PFA). First, the SPF of the P7 control standard and of the P2 control standard was determined, testing 20 subjects using the method described in the Food and Drug Administration (FDA) Final Monograph and using 150 W and 300 W SSs. In the second clinical trial, the PFA of the Japanese Cosmetic Industry Association (JCIA) control standard and of the P2 control standard was determined, testing 10 subjects using the method described in the JCIA Technical Bulletin and using 150 W and 300 W SSs. The SPF values for P7 control standard determined using the 150 W and 300 W SSs were 4.54 ± 0.35 and 4.61 ± 0.32, respectively. The SPF values for P2 control standard determined using the 150 W and 300 W SSs were 17.0 ± 0.9 and 16.7 ± 0.9, respectively. The resultant PFA values for JCIA control standard determined using the 150 W and 300 W SSs were 4.06 ± 0.70 and 4.06 ± 0.70, respectively. The resultant PFA values for P2 control standard determined using the 150 W and 300 W SSs were 3.28 ± 0.25 and 3.44 ± 0.39, respectively. As the values are essentially identical for SPF and for PFA, the 150 W and 300 W SSs can be used interchangeably for SPF and PFA determinations. © 2013 John Wiley & Sons A/S.
Effects of Nd:YAG laser-heated metal cap on human platelets in vitro
NASA Astrophysics Data System (ADS)
Liu, Xia; Guo, You-chi
1993-03-01
Human platelet-rich plasma (PRP) was irradiated in vitro with a fiberoptic Nd:YAG laser-heated metal cap to study its effects on platelets. The energy of the laser was 5 and 10 watts with an irradiation time of 0, 3, 6, and 9 seconds and 14 watts with an irradiation time of 0, 3, 4, and 5 seconds, respectively. The irradiated PRPs were analyzed for platelet count, aggregation reaction, thromboxane (TX)B2 measurement and electron microscopy. Various degrees of decrease in platelet count were observed in all groups. Except the 5Wx3S group, the other groups showed an increase in the maximum aggregation rate of platelets, which corresponded to the enhancement of TXB2 formation. It was also demonstrated by a transmission electron microscopy in 10Wx3S, 10Wx6S, 10Wx9S, 14Wx3S, 14Wx4S, and 14Wx5S energy groups that alpha- and dense-particles in irradiated platelets became sparse in number or even disappeared, less electron density, irregularity in size and shape, and a tendency for these particles to cluster around platelet membranes and open canalicular systems, which dilated apparently. Furthermore, scanning electron microscopy depicted the appearance of short and thick pseudopods on the surfaces of some irradiated platelets and an increase in the axis rate in most of the irradiated platelets.
Davis, Christopher C.; Beard, Brian B.; Tillman, Ahlia; Rzasa, John; Merideth, Eric; Balzano, Quirino
2018-01-01
This paper reports the results of an international intercomparison of the specific absorption rates (SARs) measured in a flat-bottomed container (flat phantom), filled with human head tissue simulant fluid, placed in the near-field of custom-built dipole antennas operating at 900 and 1800 MHz, respectively. These tests of the reliability of experimental SAR measurements have been conducted as part of a verification of the ways in which wireless phones are tested and certified for compliance with safety standards. The measurements are made using small electric-field probes scanned in the simulant fluid in the phantom to record the spatial SAR distribution. The intercomparison involved a standard flat phantom, antennas, power meters, and RF components being circulated among 15 different governmental and industrial laboratories. At the conclusion of each laboratory’s measurements, the following results were communicated to the coordinators: Spatial SAR scans at 900 and 1800 MHz and 1 and 10 g maximum spatial SAR averages for cubic volumes at 900 and 1800 MHz. The overall results, given as meanstandard deviation, are the following: at 900 MHz, 1 g average 7.850.76; 10 g average 5.160.45; at 1800 MHz, 1 g average 18.44 ± 1.65; 10 g average 10.14 ± 0.85, all measured in units of watt per kilogram, per watt of radiated power. PMID:29520117
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
... Draft Solicitation, contact Dr. Patricia Watts (the Contact Person listed below). DATES: The meeting..., Telephone: (703) 920-3230. FOR FURTHER INFORMATION CONTACT: Dr. Patricia Watts, National Program Director...
Preliminary Design Options for Meteor Burst Communications Systems Buoy Relays
1986-12-01
FIELDS BRAYTON OTTO ELECTROSTATIC FIELDS SUPERCRITICAL Figure 5.1. Structure of current power source technology for ocean applications. 32 L / P 9 t ~A...As in the sulphur dioxide cell, a low weight, high surface area, carbon positive elec- trode acts as a catalyst for the reduction of the cathode...Operating Transmit Power No. (Relay/Service) Type Covert Covert Mode Duty Cycle (watts) 2.1 Trans Ocean Relay Shore/Ship No Yes Remote 20 Msg/hr 0.9
DEET Insect Repellent: Effects on Thermoregulatory Sweating and Physiological Strain
2011-01-01
local measures of mean sweat rate of upper arm and forearm during 70 min of cycling exercise in *44C. They reported a significant increase in rectal...right arm of four volunteers and the left arm of the remaining five. The mid-point of the ventral forearm , between the antecubital space and the wrist...acclimation (45_C, 20% rh; 545 watts; 100 min/day) and performed three trials: control (CON); DEET applied to forearm (DEETLOC, 12 cm2 ); and DEET
Incoherent and Laser Photodeposition on Thin Films.
1980-09-01
wavelength, an incoherent Oriel Mercury arc lamp (model HR-l) with a 1000 watt u-v out- a put centered at 2537A was used. This source emitted o down...Royal Society of London Series A, 156: 108-129 (1936). 18. Gutowsky, H.S.. "The Infra-Red and Raman Spectra of Dimethyl Mercury and Dimethyl Zinc," The...II), - Cadmium (II) and - Mercury (II)," Spectrochimica Acta, 33A: 669-680 (1977). 20. Bakke, A.M.W.. "A Molecular Structure Study of Dimethylmercury
47 CFR 73.840 - Operating power and mode tolerances.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ten watts must be maintained as near as practicable to its authorized TPO and may not be less than 90... authorized TPO of ten watts or less may operate with less than the authorized power, but not more than 105...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-10
... this page, the public can gain entry into ADAMS, which provides text and image files of the NRC's... the Nuclear Regulatory Commission. Stephen J. Campbell, Chief, Watts Bar Special Projects Branch...
NREL and IBM Improve Solar Forecasting with Big Data | Energy Systems
forecasting model using deep-machine-learning technology. The multi-scale, multi-model tool, named Watt-sun the first standard suite of metrics for this purpose. Validating Watt-sun at multiple sites across the
NASA Technical Reports Server (NTRS)
Siegert, C. E.; Gourash, F.; Vasicek, R. W.
1977-01-01
The electrical and environmental requirements for a power processor system (PPS) designed to supply the appropriate voltages and currents to a 200-watt traveling wave tube (TWT) for a communication technology satellite is described. A block diagram of the PPS, the interface requirements between the PPS and spacecraft, the interface requirements between the PPS and 200-watt TWT, and the environmental requirements of the PPS are presented. Also included are discussions of protection circuits, interlocking sequences, and transient requirements. Predictions of the flight performance, based on ground test data, are provided.
Random walk in degree space and the time-dependent Watts-Strogatz model
NASA Astrophysics Data System (ADS)
Casa Grande, H. L.; Cotacallapa, M.; Hase, M. O.
2017-01-01
In this work, we propose a scheme that provides an analytical estimate for the time-dependent degree distribution of some networks. This scheme maps the problem into a random walk in degree space, and then we choose the paths that are responsible for the dominant contributions. The method is illustrated on the dynamical versions of the Erdős-Rényi and Watts-Strogatz graphs, which were introduced as static models in the original formulation. We have succeeded in obtaining an analytical form for the dynamics Watts-Strogatz model, which is asymptotically exact for some regimes.
Random walk in degree space and the time-dependent Watts-Strogatz model.
Casa Grande, H L; Cotacallapa, M; Hase, M O
2017-01-01
In this work, we propose a scheme that provides an analytical estimate for the time-dependent degree distribution of some networks. This scheme maps the problem into a random walk in degree space, and then we choose the paths that are responsible for the dominant contributions. The method is illustrated on the dynamical versions of the Erdős-Rényi and Watts-Strogatz graphs, which were introduced as static models in the original formulation. We have succeeded in obtaining an analytical form for the dynamics Watts-Strogatz model, which is asymptotically exact for some regimes.
Free-piston Stirling component test power converter test results and potential Stirling applications
NASA Technical Reports Server (NTRS)
Dochat, G. R.
1992-01-01
As the principal contractor to NASA-Lewis Research Center, Mechanical Technology Incorporated is under contract to develop free-piston Stirling power converters in the context of the competitive multiyear Space Stirling Technology Program. The first generation Stirling power converter, the component test power converter (CTPC) initiated cold end testing in 1991, with hot testing scheduled for summer of 1992. This paper reviews the test progress of the CTPC and discusses the potential of Stirling technology for various potential missions at given point designs of 250 watts, 2500 watts, and 25,000 watts.
Ku and K band GaN High Power Amplifier MMICs
2017-03-20
end Ku-band HPA operates from 13 to 14.5 GHz and delivers 48 Watts of output power with 43% PAE. A high-end Ku-band HPA operates from 15.5 to 18 GHz and...delivers 25 Watts of output power with 45% PAE. A K-band HPA operates from 19.5 to 22 GHz and delivers 18 Watts of output power with 29% PAE...15.5 and 18 GHz. The circuit is a three-stage reactively-matched amplifier. A photograph of a fabricated high-end Ku-band GaN HPA is shown as an
Azadi Oskouyi, E; Rajaei, F; Safari Variani, A; Sarokhani, M R; Javadi, A
2015-08-01
The effect of mobile phone radiation on human reproduction system is still a matter of debate. In this study, 18 male rabbits were randomly divided into two experimental groups and one control group. Experimental groups received simulated microwaves with the frequency of 950 MHz and the output power of 3 and 6 watts for 2 weeks, 2 h a day. After a week of rest, the microscopic slides from the quada of the excised epididymis were prepared. Then, the diameter of epididymis, the height of epithelium and the number of apoptotic cells in epithelium in study groups were determined. The data were compared using spss software and one-way anova test. The epithelial height and diameter of the epididymis in 3 watt and 6 watt groups had a significant decrease compared to the control group (P < 0.001), while the testosterone level only in 6 watt group was significantly decreased compared to control group. The rate of apoptosis in the epithelial cells of the epididymis had a significant increase only in 6 watt group compared to the control group (P < 0.001). This study showed that the microwaves with the frequency of 950 MHz can have negative impacts on morphometric and apoptotic changes of rabbit epididymis. © 2014 Blackwell Verlag GmbH.
Reduced Exercise Tolerance and Pulmonary Capillary Recruitment with Remote Secondhand Smoke Exposure
Arjomandi, Mehrdad; Haight, Thaddeus; Sadeghi, Nasrat; Redberg, Rita; Gold, Warren M.
2012-01-01
Rationale Flight attendants who worked on commercial aircraft before the smoking ban in flights (pre-ban FAs) were exposed to high levels of secondhand smoke (SHS). We previously showed never-smoking pre-ban FAs to have reduced diffusing capacity (Dco) at rest. Methods To determine whether pre-ban FAs increase their Dco and pulmonary blood flow () during exercise, we administered a symptom-limited supine-posture progressively increasing cycle exercise test to determine the maximum work (watts) and oxygen uptake () achieved by FAs. After 30 min rest, we then measured Dco and at 20, 40, 60, and 80 percent of maximum observed work. Results The FAs with abnormal resting Dco achieved a lower level of maximum predicted work and compared to those with normal resting Dco (mean±SEM; 88.7±2.9 vs. 102.5±3.1%predicted ; p = 0.001). Exercise limitation was associated with the FAs' FEV1 (r = 0.33; p = 0.003). The Dco increased less with exercise in those with abnormal resting Dco (mean±SEM: 1.36±0.16 vs. 1.90±0.16 ml/min/mmHg per 20% increase in predicted watts; p = 0.020), and amongst all FAs, the increase with exercise seemed to be incrementally lower in those with lower resting Dco. Exercise-induced increase in was not different in the two groups. However, the FAs with abnormal resting Dco had less augmentation of their Dco with increase in during exercise (mean±SEM: 0.93±0.06 vs. 1.47±0.09 ml/min/mmHg per L/min; p<0.0001). The Dco during exercise was inversely associated with years of exposure to SHS in those FAs with ≥10 years of pre-ban experience (r = −0.32; p = 0.032). Conclusions This cohort of never-smoking FAs with SHS exposure showed exercise limitation based on their resting Dco. Those with lower resting Dco had reduced pulmonary capillary recruitment. Exposure to SHS in the aircraft cabin seemed to be a predictor for lower Dco during exercise. PMID:22493689
Code of Federal Regulations, 2010 CFR
2010-01-01
... with ceiling fan light kits that have medium screw base sockets shall conform to the requirements... testing pin-based fluorescent lamps packaged with ceiling fan light kits that have pin-based sockets shall... base sockets, measure the efficacy, expressed in lumens per watt, in accordance with the test...
Mayer, A S; Phillips, C R; Keller, U
2018-04-11
The original version of this Article contained an error in Fig. 3a, in which the delay axis was incorrectly labeled in increments of 0.5 ps instead of the correct 0.2 ps. This has been corrected in both the PDF and HTML versions of the Article.
47 CFR 76.610 - Operation in the frequency bands 108-137 and 225-400 MHz-scope of application.
Code of Federal Regulations, 2013 CFR
2013-10-01
... COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical... applicable to all MVPDs (cable and non-cable) transmitting carriers or other signal components carried at an average power level equal to or greater than 10−4 watts across a 25 kHz bandwidth in any 160 microsecond...
47 CFR 76.610 - Operation in the frequency bands 108-137 and 225-400 MHz-scope of application.
Code of Federal Regulations, 2010 CFR
2010-10-01
... COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical... applicable to all MVPDs (cable and non-cable) transmitting carriers or other signal components carried at an average power level equal to or greater than 10−4 watts across a 25 kHz bandwidth in any 160 microsecond...
47 CFR 76.610 - Operation in the frequency bands 108-137 and 225-400 MHz-scope of application.
Code of Federal Regulations, 2014 CFR
2014-10-01
... COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical... applicable to all MVPDs (cable and non-cable) transmitting carriers or other signal components carried at an average power level equal to or greater than 10−4 watts across a 25 kHz bandwidth in any 160 microsecond...
47 CFR 76.610 - Operation in the frequency bands 108-137 and 225-400 MHz-scope of application.
Code of Federal Regulations, 2012 CFR
2012-10-01
... COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical... applicable to all MVPDs (cable and non-cable) transmitting carriers or other signal components carried at an average power level equal to or greater than 10−4 watts across a 25 kHz bandwidth in any 160 microsecond...
A brushless dc spin motor for momentum exchange altitude control
NASA Technical Reports Server (NTRS)
Stern, D.; Rosenlieb, J. W.
1972-01-01
Brushless dc spin motor is designed to use Hall effect probes as means of revolving rotor position and controlling motor winding currents. This results in 3 to 1 reduction in watt-hours required for wheel acceleration, a 2 to 1 reduction in power to run wheel, and a 10 to 1 reduction in the electronics size and weight.
Contact diode laser application through a fiberoptic cutting tip.
Peyman, G A; Cruz, S A; Ruiz-Lapuente, C
1991-01-01
We applied diode laser energy through a fiberoptic probe to cut ocular structures. The diameter of the probe's tip was 100 microns. The amount of energy used for cutting the lid, the cornea, or for perforation of the glove was 2.5 watts in the continuous mode. The incised border demonstrated coagulation into the healthy tissue ranging from 10 to 50 microns.
Thermal conductivity of metals
NASA Technical Reports Server (NTRS)
Kazem, Sayyed M.
1990-01-01
The objective is to familiarize students with steady and unsteady heat transfer by conduction and with the effect of thermal conductivity upon temperature distribution through a homogeneous substance. The elementary heat conduction experiment presented is designed for associate degree technology students in a simple manner to enhance their intuition and to clarify many confusing concepts such as temperature, thermal energy, thermal conductivity, heat, transient and steady flows. The equipment set is safe, small, portable (10 kg) and relatively cheap (about $1200): the electric hot plate 2 kg (4.4 lb) for $175: the 24 channel selector and Thermocouple Digital Readout (Trendicator) 4.5 kg (10 lb) for about $1000; the three metal specimens (each of 2.5 cm diameter and 11 cm length), base plate and the bucket all about 3 kg (7 lb) for about $25. The experiment may take from 60 to 70 minutes. Although the hot plate surface temperature could be set from 90 to 370 C (maximum of 750 watts) it is a good practice to work with temperatures of 180 to 200 C (about 400 watts). They may experiment in squads of 2, 3 or even 4, or the instructor may demonstrate it for the whole class.
47 CFR 22.1015 - Repeater operation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the time. Table I-2—Maximum ERP (Watts) Distance from the 4.8 km (3 mi) limit 30 meters (100 feet) 61 meters (200 feet) 6.4 km (4 mi) 25 6 8.0 km (5 mi) 40 10 9.7 km (6 mi) 65 15 11.3 km (7 mi) 100 25 12.9 km (8 mi) 150 35 14.5 km (9 mi) 215 50 16.1 km (10 mi) 295 70 17.7 km (11 mi) 400 100 19.3 km (12 mi...
New World Vistas: Air and Space Power for the 21st Century. Directed Energy Volume
1995-01-01
single mode diode pumped Thulium doped glass fiber laser. Full scale 5-10 watt devices have operated in the laboratory at overall efficiencies of 10...operating in the 900-950 nm range together with the development of ytterbium (Yb) doped laser crystals. The Yb ion generates roughly one third as much...mirror in the high power oscillator resonator . Since a potentially large amount of power is dissipated in the nonlinear medium, careful attention to
NASA Astrophysics Data System (ADS)
Hamudi, Walid K.
1996-12-01
HAZ, porosity and cracks were investigated when welding 0.9 mm thick titanium sheets using a 10 J pulsed Nd: Yag laser. The effects of welding speed, joints fit-up, shielding gas, and laser parameters are presented. For optimum welding quality, 0.25 m/min scanning speed, 10 ℓ/min gas flow rate and 72 Watt average power were used. Welds of narrow heat affected zone (HAZ) with small level of porosity were obtained.
Test results of a ten cell bipolar nickel-hydrogen battery
NASA Technical Reports Server (NTRS)
Cataldo, R. L.
1983-01-01
A ten cell bipolar nickel hydrogen 6.5 ampere-hour battery demonstrated over 2000 low earth orbit cycles at an 80 percent depth-of-discharge. Charge/discharge cyclic ampere-hour and watt-hour efficiencies of 88 and 76 percent, respectively, observed. Peak power capability was determined at 1.1 kW. A 10C discharge rate yields 83 percent of the nominal stark capacity to the 1.0 volt cut off in just under 6 minutes. Previously announced in STAR as N83-26253
Women match men when learning a spatial skill.
Spence, Ian; Yu, Jingjie Jessica; Feng, Jing; Marshman, Jeff
2009-07-01
Meta-analytic studies have concluded that although training improves spatial cognition in both sexes, the male advantage generally persists. However, because some studies run counter to this pattern, a closer examination of the anomaly is warranted. The authors investigated the acquisition of a basic skill (spatial selective attention) using a matched-pair two-wave longitudinal design. Participants were screened with the use of an attentional visual field task, with the objective of selecting and matching 10 male-female pairs, over a wide range (30% to 57% correct). Subsequently, 20 participants 17-23 years of age (selected from 43 screened) were trained for 10 hr (distributed over several sessions) by playing a first-person shooter video game. This genre is known to be highly effective in enhancing spatial skills. All 20 participants improved, with matched members of the male-female pairs achieving very similar gains, independent of starting level. This is consistent with the hypothesis that the learning trajectory of women is not inferior to that of men when acquiring a basic spatial skill. Training methods that develop basic spatial skills may be essential to achieve gender parity in both basic and complex spatial tasks.
Generating electricity while walking with loads.
Rome, Lawrence C; Flynn, Louis; Goldman, Evan M; Yoo, Taeseung D
2005-09-09
We have developed the suspended-load backpack, which converts mechanical energy from the vertical movement of carried loads (weighing 20 to 38 kilograms) to electricity during normal walking [generating up to 7.4 watts, or a 300-fold increase over previous shoe devices (20 milliwatts)]. Unexpectedly, little extra metabolic energy (as compared to that expended carrying a rigid backpack) is required during electricity generation. This is probably due to a compensatory change in gait or loading regime, which reduces the metabolic power required for walking. This electricity generation can help give field scientists, explorers, and disaster-relief workers freedom from the heavy weight of replacement batteries and thereby extend their ability to operate in remote areas.
Comparison of Physical and Physiological Profiles in Elite and Amateur Young Wrestlers.
Demirkan, Erkan; Koz, Mitat; Kutlu, Mehmet; Favre, Mike
2015-07-01
The aim of this study is to examine the physical and physiological determinants of wrestling success between elite and amateur male wrestlers. The wrestlers (N = 126) were first assigned to 3 groups based on their competitive level (top elite, elite, and amateur) and then to 6 groups according to their body mass (light, middle, and heavy weight) and their competitive level (elite and amateur). Top elite and elite wrestlers had significantly (p ≤ 0.05) more training experiences and maximal oxygen uptake compared with the amateur group. In separating weight classes, light- and middle-weight elite (MWE) wrestlers had significantly (p ≤ 0.05) more training experience (7-20%) compared with the light- and middle-weight amateur (MWA) wrestlers. No significant differences were detected between elite and amateur groups (light-, middle-, and heavy-weight wrestlers) for age, body mass, height, body mass index, and body fat (p > 0.05), with the exception of height for heavy wrestlers. Leg average and peak power values (in watts and watts per kilogram) in MWE were higher than MWA (6.5 and 13%, p ≤ 0.05). Relative leg average power value in heavy-weight elite (HWE) (in watts per kilogram) was higher than heavy-weight amateur (HWA) (9.6%, p ≤ 0.05). It was seen that elite wrestlers in MWE and HWE statistically possessed a higher V̇O2max (12.5 and 11.4%, respectively) than amateur middle- and heavy-weight wrestlers (p ≤ 0.05). The results of this study suggest that training experience, aerobic endurance, and anaerobic power and capacity will give a clear advantage for the wrestlers to take part in the elite group.
A high specific power solar array for low to mid-power spacecraft
NASA Technical Reports Server (NTRS)
Jones, P. Alan; White, Stephen F.; Harvey, T. Jeffery; Smith, Brian S.
1993-01-01
UltraFlex is the generic term for a solar array system which delivers on-orbit power in the 400 to 6,000 watt per wing sizes with end-of-life specific power performance ranging to 150 watts-per-kilogram. Such performance is accomplished with off-the-shelf solar cells and state-of the-art materials and processes. Much of the recent work in photovoltaics is centered on advanced solar cell development. Successful as such work has been, no integrated solar array system has emerged which meets NASA's stated goals of 'increasing the end-of-life performance of space solar cells and arrays while minimizing their mass and cost.' This issue is addressed; namely, is there an array design that satisfies the usual requirements for space-rated hardware and that is inherently reliable, inexpensive, easily manufactured and simple, which can be used with both advanced cells currently in development and with inexpensive silicon cells? The answer is yes. The UltraFlex array described incorporates use of a blanket substrate which is thermally compatible with silicon and other materials typical of advanced multi-junction devices. The blanket materials are intrinsically insensitive to atomic oxygen degradation, are space rated, and are compatible with standard cell bonding processes. The deployment mechanism is simple and reliable and the structure is inherently stiff (high natural frequency). Mechanical vibration modes are also readily damped. The basic design is presented as well as supporting analysis and development tests.
A high specific power solar array for low to mid-power spacecraft
NASA Astrophysics Data System (ADS)
Jones, P. Alan; White, Stephen F.; Harvey, T. Jeffery; Smith, Brian S.
1993-05-01
UltraFlex is the generic term for a solar array system which delivers on-orbit power in the 400 to 6,000 watt per wing sizes with end-of-life specific power performance ranging to 150 watts-per-kilogram. Such performance is accomplished with off-the-shelf solar cells and state-of the-art materials and processes. Much of the recent work in photovoltaics is centered on advanced solar cell development. Successful as such work has been, no integrated solar array system has emerged which meets NASA's stated goals of 'increasing the end-of-life performance of space solar cells and arrays while minimizing their mass and cost.' This issue is addressed; namely, is there an array design that satisfies the usual requirements for space-rated hardware and that is inherently reliable, inexpensive, easily manufactured and simple, which can be used with both advanced cells currently in development and with inexpensive silicon cells? The answer is yes. The UltraFlex array described incorporates use of a blanket substrate which is thermally compatible with silicon and other materials typical of advanced multi-junction devices. The blanket materials are intrinsically insensitive to atomic oxygen degradation, are space rated, and are compatible with standard cell bonding processes. The deployment mechanism is simple and reliable and the structure is inherently stiff (high natural frequency). Mechanical vibration modes are also readily damped. The basic design is presented as well as supporting analysis and development tests.
Validation of the Berlese-funnel technique for thrips extraction.
Casteels, H; Witters, J; De Bondt, G; Desamblanx, J
2009-01-01
In order to get the accreditation EN ISO/IEC 17025 for Thrips palmi the Berlese-funnel technique, which is used for the isolation of quarantine insects out of plant material, was validated. Following parameters were investigated: cleaning of the funnel, temperature during isolation, detection limit and duration of the isolation period. Thrips fuscipennis was collected from heavily infected rosehip and used as target organism. Besides orchids, artificially contaminated maple leaves (Acer pseudoplatanus) were used for the validation. Results showed that thrips and other organisms can be present alive or dead in the funnel after removing the treated plants and can contaminate the next sample or isolate. Cleaning of the funnel with a vacuum cleaner and compressed-air apparatus is necessary before running a new extraction. Contamination of the recipient is also possible from the environment. This can be avoided by closing the opening between the funnel and the recipient. To reach an optimal temperature for isolation of the thrips a 60 Watt bulb is necessary. The results showed that the maximum temperature doesn't reach a temperature above 51 degrees C, the average temperatures were situated between 35, 74 degrees C and 39, 38 degrees C. A 40 Watt bulb doesn't create enough heat to guarantee an efficient isolation of the thrips; the average temperature was 34, 74 degrees C and the maximum temperature 36, 80 degrees C. Based on the results we can conclude that an isolation time of 20 hours is necessary to obtain accurate data. Dependent on the number of thrips in the artificially infected samples 87 to 95% is isolated after 20 hours. The detection limit is 1 thrips with a probability of 95% being isolated after 20 hours.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoke, Anderson F.; Nelson, Austin A.; Tan, Jin
This interim report describes research related to frequency-watt control of solar photovoltaic (PV) inverters conducted under the U.S. Department of Energy's Grid Modernization Laboratory Consortium (GMLC) by a regional partnership for Hawaii. The purpose of this report is to inform an ongoing discussion around frequency-watt control activation in Hawaii.
300-Watt Power Source Development at the Jet Propulsion Laboratory
NASA Technical Reports Server (NTRS)
Valdez, Thomas I.
2005-01-01
This viewgraph presentation reviews the JPL program to develop a 300 Watt direct methanol fuel cell. The immediate use of the fuel cell is to power test instrumentation on armored vehicles. It reviews the challenges, the system design and the system demonstration.
The Development and Application of the Magnetron,
1982-03-31
of *medicine. The power of the magnetron used is from several tens of watts to several hundred watts. Microwave physiotherapy has been used in...clinical practice for the fast cure of arthritis , rheumatism and the subsidence of swelling. Therapeutic results have been excellent. In recent years
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-23
... image files of the NRC's public documents. If you do not have access to ADAMS or if there are problems.... Stephen J. Campbell, Chief, Watts Bar Special Projects Branch, Division of Operating Reactor Licensing...
Design of small Stirling dynamic isotope power system for robotic space missions
NASA Technical Reports Server (NTRS)
Bents, D. J.; Schreiber, J. G.; Withrow, C. A.; Mckissock, B. I.; Schmitz, P. C.
1992-01-01
Design of a multihundred-watt Dynamic Isotope Power System (DIPS) based on the U.S. Department of Energy (DOE) General Purpose Heat Source (GPHS) and small (multihundred-watt) free-piston Stirling engine (FPSE) technology is being pursued as a potential lower cost alternative to radioisotope thermoelectric generators (RTG's). The design is targeted at the power needs of future unmanned deep space and planetary surface exploration missions ranging from scientific probes to Space Exploration Initiative precursor missions. Power level for these missions is less than a kilowatt. Unlike previous DIPS designs which were based on turbomachinery conversion (e.g. Brayton), this small Stirling DIPS can be advantageously scaled down to multihundred-watt unit size while preserving size and mass competitiveness with RTG's. Preliminary characterization of units in the output power ranges 200-600 We indicate that on an electrical watt basis the GPHS/small Stirling DIPS will be roughly equivalent to an advanced RTG in size and mass but require less than a third of the isotope inventory.
A LEGO Watt balance: An apparatus to determine a mass based on the new SI
NASA Astrophysics Data System (ADS)
Chao, L. S.; Schlamminger, S.; Newell, D. B.; Pratt, J. R.; Seifert, F.; Zhang, X.; Sineriz, G.; Liu, M.; Haddad, D.
2015-11-01
A global effort to redefine our International System of Units (SI) is underway, and the change to the new system is expected to occur in 2018. Within the newly redefined SI, the present base units will still exist but be derived from fixed numerical values of seven reference constants. In particular, the unit of mass (the kilogram) will be realized through a fixed value of the Planck constant h. A so-called watt balance, for example, can then be used to realize the kilogram unit of mass within a few parts in 108. Such a balance has been designed and constructed at the National Institute of Standards and Technology. For educational outreach and to demonstrate the principle, we have constructed a LEGO tabletop watt balance capable of measuring a gram-level masses to 1% relative uncertainty. This article presents the design, construction, and performance of the LEGO watt balance and its ability to determine h.
NASA Astrophysics Data System (ADS)
Sapteka, A. A. N. G.; Narottama, A. A. N. M.; Winarta, A.; Amerta Yasa, K.; Priambodo, P. S.; Putra, N.
2018-01-01
Solar energy utilized with solar panel is a renewable energy that needs to be studied further. The site nearest to the equator, it is not surprising, receives the highest solar energy. In this paper, a modelling of electrical characteristics of 150-Watt peak solar panels using Boltzmann sigmoid function under various temperature and irradiance is reported. Current, voltage, temperature and irradiance data in Denpasar, a city located at just south of equator, was collected. Solar power meter is used to measure irradiance level, meanwhile digital thermometer is used to measure temperature of front and back panels. Short circuit current and open circuit voltage data was also collected at different temperature and irradiance level. Statistically, the electrical characteristics of 150-Watt peak solar panel can be modelled using Boltzmann sigmoid function with good fit. Therefore, it can be concluded that Boltzmann sigmoid function might be used to determine current and voltage characteristics of 150-Watt peak solar panel under various temperature and irradiance.
Mobile electric power. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bloomfield, D.P.; Bloomfield, V.J.; Grosjean, P.D.
1995-12-01
The objective of this program was to develop a mobile fuel cell power supply for use by soldiers. The Century Series of 100 through 500 watt fuel cell power supplies was developed. The Century Series fuel cell power supplies are made up of a fuel cell stack, chemical hydride hydrogen supply, a fan and a controller. The FC-200, the 200 watt Century Series power supply, weighs 8.8 ib. and has a volume of 322 in.3. The operating point is 0.7 volt/cell at 125 ASF; a power density of 22.7 watts/lb. or 0.62 watts/in.3 and an energy density of 110 whr/lb.more » The prototype 750 whr hydrogen supply weighs 7 lbs. and has a volume of 193 in.3. The fuel elements weigh 0.45 lb. and require 0.79 lbs. of water. The FC-200 has powered a scooter requiring a starting current of three times the rated current of the stack. It has also powered a microclimate cooler. (KAR) P. 1.« less
NASA Astrophysics Data System (ADS)
Bloomfield, David P.; Bloomfield, Valerie J.; Grosjean, Paul D.; Kelland, James W.
1995-02-01
The objective of this program was to develop a mobile fuel cell power supply for use by soldiers. The Century Series of 100 through 500 watt fuel cell power supplies was developed. The Century Series fuel cell power supplies are made up of a fuel cell stack, chemical hydride hydrogen supply, a fan and a controller. The FC-200, the 200 watt Century Series power supply, weighs 8.8 lb. and has a volume of 322 cu in. The operating point is 0.7 volt/cell at 125 ASF; a power density of 22.7 watts/cu in. or 0.62 watts/cu in. and an energy density of 110 whr/lb. The prototype 750 whr hydrogen supply weighs 7 lbs. and has a volume of 193 cu in. The fuel elements weigh 0.45 lb. and require 0.79 lbs. of water. The FC-200 has powered a scooter requiring a starting current of three times the rated current of the stack. It has also powered a microclimate cooler.
Afroundeh, R; Arimitsu, T; Yamanaka, R; Lian, C S; Shirakawa, K; Yunoki, T; Yano, T
2014-01-01
Time delay in the mediation of ventilation (V(.)E) by arterial CO(2) pressure (PaCO(2)) was studied during recovery from short impulse-like exercises with different work loads of recovery. Subjects performed two tests including 10-s impulse like exercise with work load of 200 watts and 15-min recovery with 25 watts in test one and 50 watts in test two. V(.)E, end tidal CO(2) pressure (PETCO(2)) and heart rate (HR) were measured continuously during rest, warming up, exercise and recovery. PaCO(2) was estimated from PETCO(2) and tidal volume (V(T)). Results showed that predicted arterial CO(2) pressure (PaCO(2 pre)) increased during recovery in both tests. In both tests, V(.)E increased and peaked at the end of exercise. V(.)E decreased in the first few seconds of recovery but started to increase again. The highest correlation coefficient between PaCO(2 pre) and V(.)E was obtained in the time delay of 7 s (r=0.854) in test one and in time delays of 6 s (r=0.451) and 31 s (r=0.567) in test two. HR was significantly higher in test two than in test one. These results indicate that PaCO(2 pre) drives V(.)E with a time delay and that higher work intensity induces a shorter time delay.
Duray, S J; Lee, S Y; Menis, D L; Gilbert, J L; Lautenschlager, E P; Greener, E H
1996-01-01
This study was designed to investigate a new method for generating interfacial debonding between the resin matrix and filler particles of dental composites. A pilot study was conducted to evaluate laser-induced acoustic emission in dental resins filled with varying quantities of particles. Model systems of 50/50 BisGMA/TEGDMA resin reinforced with 0, 25, and 75 wt% 5-10 micrometers silanated BaSiO(6) were analyzed. The sample size was 3.5 mm diameter x 0.25-0.28 mm thick. A continuous wave CO2 laser (Synrad Infrared Gas Laser Model 48-1) was used to heat the composite samples. Acoustic events were detected, recorded and processed by a model 4610 Smart Acoustic Monitor (SAM) with a 1220A preamp (Physical Acoustic Corp.) as a function of laser power. Initially, the acoustic signal from the model composites produced a burst pattern characteristic of fracturing, about 3.7 watts laser power. Acoustic emission increased with laser power up to about 6 watts. At laser powers above 6 watts, the acoustic emission remained constant. The amount of acoustic emission followed the trend: unfilled resin > composite with 25 wt% BaSiO(6) > composite with 75 wt% BaSiO(6). Acoustic emission generated by laser thermal heating is dependent on the weight percent of filler particles in the composite and the amount of laser power. For this reason, laser thermal acoustic emission might be useful as a nondestructive form of analysis of dental composites.
NASA Technical Reports Server (NTRS)
Hayashi, K.; Thabit, G. 3rd; Vailas, A. C.; Bogdanske, J. J.; Cooley, A. J.; Markel, M. D.
1996-01-01
The purpose of this study was to evaluate the effect of laser energy at nonablative levels on joint capsular histologic and biochemical properties in an in vitro rabbit model. The medial and lateral portions of the femoropatellar joint capsule from both stifles of 12 mature New Zealand White rabbits were used. Specimens were divided into three treatment groups (5 watts, 10 watts, and 15 watt) and one control group using a randomized block design. Specimens were placed in a 37 degrees bath of lactated Ringer's solution and laser energy was applied using a holmium:yttrium-aluminum-garnet laser in four transverse passes across the tissue at a velocity of 2 mm/sec with the handpiece set 1.5 mm from the synovial surface. Histologic analysis revealed thermal alteration of collagen (fusion) and fibroblasts (pyknosis) at all energy densities, with higher laser energy causing significantly greater morphologic changes over a larger area (P < 0.05). Application of laser energy did not significantly alter the biochemical parameters evaluated, including type I collagen content and nonreducible crosslinks (P > 0.05). This study demonstrated that nonablative laser energy caused significant thermal damage to the joint capsular tissue in an energy-dependent fashion, but type I collagen content and nonreducible crosslinks (P > 0.05). This study demonstrated that nonablative laser energy caused significant thermal damage to the joint capsular tissue in an energy-dependent fashion, but type I Collagen content and nonreducible corsslinks were not significantly altered.
Analysis of a 10 megawatt space-based solar-pumped neodymium laser system
NASA Technical Reports Server (NTRS)
Kurweg, U. H.
1984-01-01
A ten megawatt solar-pumped continuous liquid laser system for space applications is examined. It is found that a single inflatable mirror of 434 m diameter used in conjunction with a conical secondary concentrator is sufficient to side pump a liquid neodymium lasant in an annular tube of 6 m length and 1 m outer and 0.8 m inner diameter. About one fourth of intercepted radiation converging on the laser tube is absorbed and one fifth of this radiation is effective in populating the upper levels. The liquid lasant is flowed through the annular laser cavity at 1.9 m/s and is cooled via a heat exchanger and a large radiator surface comparable in size to the concentrating mirror. The power density of incident light within the lasant of approximately 68 watt/cu cm required for cw operation is exceeded in the present annular configuration. Total system weight corresponds to 20,500 kg and is thus capable of being transported to near Earth orbit by a single shuttle flight.
Thermal Performance of ATLAS Laser Thermal Control System Demonstration Unit
NASA Technical Reports Server (NTRS)
Ku, Jentung; Robinson, Franklin; Patel, Deepak; Ottenstein, Laura
2013-01-01
The second Ice, Cloud, and Land Elevation Satellite mission currently planned by National Aeronautics and Space Administration will measure global ice topography and canopy height using the Advanced Topographic Laser Altimeter System {ATLAS). The ATLAS comprises two lasers; but only one will be used at a time. Each laser will generate between 125 watts and 250 watts of heat, and each laser has its own optimal operating temperature that must be maintained within plus or minus 1 degree Centigrade accuracy by the Laser Thermal Control System (LTCS) consisting of a constant conductance heat pipe (CCHP), a loop heat pipe (LHP) and a radiator. The heat generated by the laser is acquired by the CCHP and transferred to the LHP, which delivers the heat to the radiator for ultimate rejection. The radiator can be exposed to temperatures between minus 71 degrees Centigrade and minus 93 degrees Centigrade. The two lasers can have different operating temperatures varying between plus 15 degrees Centigrade and plus 30 degrees Centigrade, and their operating temperatures are not known while the LTCS is being designed and built. Major challenges of the LTCS include: 1) A single thermal control system must maintain the ATLAS at 15 degrees Centigrade with 250 watts heat load and minus 71 degrees Centigrade radiator sink temperature, and maintain the ATLAS at plus 30 degrees Centigrade with 125 watts heat load and minus 93 degrees Centigrade radiator sink temperature. Furthermore, the LTCS must be qualification tested to maintain the ATLAS between plus 10 degrees Centigrade and plus 35 degrees Centigrade. 2) The LTCS must be shut down to ensure that the ATLAS can be maintained above its lowest desirable temperature of minus 2 degrees Centigrade during the survival mode. No software control algorithm for LTCS can be activated during survival and only thermostats can be used. 3) The radiator must be kept above minus 65 degrees Centigrade to prevent ammonia from freezing using no more than 135 watts of heater power. 4) The LHP reservoir control heater power is limited to 15 watts with a 70 percent duty cycle. 5) The voltage of the power supply can vary between 26 volts direct current and 34 volts direct current during the spacecraft lifetime. A design analysis shows that a single LTCS can satisfy these requirements. However, shutdown of· the LHP is particularly challenging and the shutdown heater must be wired in series with two reservoir thermostats and two CCHP thermostats at different set points. An LTCS demonstration unit has been tested to verify these performance characteristics experimentally prior to proceeding to the final LTCS design and fabrication. Test results showed that the LHP shutdown scheme would be able to shut down the LHP as designed and the reservoir control heater can maintain the ATLAS mass simulator within the plus or minus 1 degrees Centigrade accuracy under various combinations of the heat load, sink temperature, and power supply voltage.
2012-07-01
Small Unmanned Aircraft Systems vs. Air Combat Telemetry Systems SUAS - 2 Watts vs. ACTS 100 Watts... SUAS - 25 km normal radius vs. ACTS 200 km normal radius Primary Concerns: Operational Small Unmanned Aircraft Systems ...Std Z39-18 UNCLASSIFIED UNCLASSIFIED Army Unmanned Aircraft Systems 2 Provides the small unit the
Some results regarding stability of photovoltaic maximum-power-point tracking dc-dc converters
NASA Astrophysics Data System (ADS)
Schaefer, John F.
An analytical investigation of a class of photovoltaic (PV) maximum-power-point tracking dc-dc converters has yielded basic results relative to the stability of such devices. Necessary and sufficient conditions for stable operation are derived, and design tools are given. Specific results have been obtained for arbitrary PV arrays driving converters powering resistive loads and batteries. The analytical techniques are applicable to inverters, also. Portions of the theoretical results have been verified in operational devices: a 1500 watt unit has driven a 1-horsepower, 90-volt dc motor powering a water pump jack for over one year. Prior to modification shortly after initial installation, the unit exhibited instability at low levels of irradiance, as predicted by the theory. Two examples are provided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ingham, J.G.
Maximum cladding temperatures occur when the IDENT 1578 fuel pin shipping container is installed in the T-3 Cask. The maximum allowable cladding temperature of 800/sup 0/F is reached when the rate of energy deposited in the 19-pin basket reaches 400 watts. Since 45% of the energy which is generated in the fuel escapes the 19-pin basket without being deposited, mostly gamma energy, the maximum allowable rate of heat generation is 400/.55 = 727 watts. Similarly, the maximum allowable cladding temperature of 800/sup 0/F is reached when the rate of energy deposited in the 40-pin basket reaches 465 watts. Since 33%more » of the energy which is generated in the fuel escapes the 40-pin basket without being deposited, mostly gamma energy, the maximum allowable rate of heat generation is 465/.66 = 704 watts. The IDENT 1578 fuel pin shipping container therefore meets its thermal design criteria. IDENT 1578 can handle fuel pins with a decay heat load of 600 watts while maintaining the maximum fuel pin cladding temperature below 800/sup 0/F. The emissivities which were determined from the test results for the basket tubes and container are relatively low and correspond to new, shiny conditions. As the IDENT 1578 container is exposed to high temperatures for extended periods of time during the transportation of fuel pins, the emissivities will probably increase. This will result in reduced temperatures.« less
Quantitative Analysis of Electroplated Nickel Coating on Hard Metal
Wahab, Hassan A.; Noordin, M. Y.; Izman, S.
2013-01-01
Electroplated nickel coating on cemented carbide is a potential pretreatment technique for providing an interlayer prior to diamond deposition on the hard metal substrate. The electroplated nickel coating is expected to be of high quality, for example, indicated by having adequate thickness and uniformity. Electroplating parameters should be set accordingly for this purpose. In this study, the gap distances between the electrodes and duration of electroplating process are the investigated variables. Their effect on the coating thickness and uniformity was analyzed and quantified using design of experiment. The nickel deposition was carried out by electroplating in a standard Watt's solution keeping other plating parameters (current: 0.1 Amp, electric potential: 1.0 V, and pH: 3.5) constant. The gap distance between anode and cathode varied at 5, 10, and 15 mm, while the plating time was 10, 20, and 30 minutes. Coating thickness was found to be proportional to the plating time and inversely proportional to the electrode gap distance, while the uniformity tends to improve at a large electrode gap. Empirical models of both coating thickness and uniformity were developed within the ranges of the gap distance and plating time settings, and an optimized solution was determined using these models. PMID:23997678
Cho, Jay; Freivalds, Andris; Rovniak, Liza S.
2017-01-01
This study investigated the feasibility of using a desk bike in an office setting. Workstation measurements were introduced to accommodate 95% of the general U.S. population in using desk bikes. Reading and typing performances were compared at three different cycling conditions (no cycling, 10 and 25 watts). Thirty healthy individuals (15 female and 15 male; Age mean: 23.1, σ: 4.19) were recruited based on 5/50/95th percentile stature. Participants were required to select preferred workstation settings and perform reading and typing tasks while pedaling. According to anthropometric measurements and variability from user preference, recommended adjustable ranges of workstation settings for the general U.S. population were derived. Repeated measures ANOVA showed that pedaling had no significant effect on reading comprehension (p > .05), but had significant effect on typing performance (p < .001). A preferred level of cycling intensity was determined (mean 17.3 watts, σ: 3.69). PMID:28166871
Radiation Testing of PICA at the Solar Power Tower
NASA Technical Reports Server (NTRS)
White, Susan M.
2010-01-01
Sandia National Laboratory's Solar Power Tower was used to irradiate specimens of Phenolic Impregnated Carbon Ablator (PICA), in order to evaluate whether this thermal protection system material responded differently to potential shock layer radiative heating than to convective heating. Tests were run at 50, 100 and 150 Watts per square centimeter levels of concentrated solar radiation. Experimental results are presented both from spectral measurements on 1- 10 mm thick specimens of PICA, as well as from in-depth temperature measurements on instrumented thicker test specimens. Both spectral measurements and measured in-depth temperature profiles showed that, although it is a porous, low-density material, PICA does not exhibit problematic transparency to the tested high levels of NIR radiation, for all pragmatic cm-to-inch scale thicknesses. PICA acted as a surface absorber to efficiently absorb the incident visible and near infrared incident radiation in the top 2 millimeter layer in the Solar Power Tower tests up to 150 Watts per square centimeter.
Production of High Intracavity UV Power From a CW Laser Source
NASA Technical Reports Server (NTRS)
David, R. T.; Chyba, T. H.; Keppel, C. E.; Gaskell, D.; Ent, R.
1998-01-01
The goal of this research project is to create a prototype high power CW source of ultraviolet (UV) photons for photon-electron scattering at the Thomas Jefferson National Accelerator Facility (TJNAF), Hall B. The facility will use optical resonant cavities to produce a high photon flux. The technical approach will be to frequency-double the 514.5 mn light from an Argon-Ion Laser to create 0.1 to 1.0 watt in the UV. The produced UV power will be stored in a resonant cavity to generate an high intracavity UV power of 102 to 103 watts. The specific aim of this project is to first design and construct the low-Q doubling cavity and lock it to the Argon-Ion wavelength. Secondly, the existing 514.5 nm high-Q build-up cavity and its locking electronics will be modified to create high intracavity UV power. The entire system will then be characterized and evaluated for possible beam line use.
Narrow linewidth picosecond UV pulsed laser with mega-watt peak power.
Huang, Chunning; Deibele, Craig; Liu, Yun
2013-04-08
We demonstrate a master oscillator power amplifier (MOPA) burst mode laser system that generates 66 ps/402.5 MHz pulses with mega-watt peak power at 355 nm. The seed laser consists of a single frequency fiber laser (linewidth < 5 KHz), a high bandwidth electro-optic modulator (EOM), a picosecond pulse generator, and a fiber based preamplifier. A very high extinction ratio (45 dB) has been achieved by using an adaptive bias control of the EOM. The multi-stage Nd:YAG amplifier system allows a uniformly temporal shaping of the macropulse with a tunable pulse duration. The light output from the amplifier is converted to 355 nm, and over 1 MW peak power is obtained when the laser is operating in a 5-μs/10-Hz macropulse mode. The laser output has a transform-limited spectrum with a very narrow linewidth of individual longitudinal modes. The immediate application of the laser system is the laser-assisted hydrogen ion beam stripping for the Spallation Neutron Source (SNS).
Preliminary design trade-offs for a multi-mission stored cryogen cooler
NASA Technical Reports Server (NTRS)
Sherman, A.
1978-01-01
Preliminary design studies were performed for a multi-mission solid cryogen cooler having a wide range of application for both the shuttle sortie and free flyer missions. This multi-mission cooler (MMC) is designed to be utilized with various solid cryogens to meet a wide range of instrument cooling from 10 K (with solid hydrogen) to 90 K. The baseline cooler utilizes two stages of solid cryogen and incorporates an optional, higher temperature third stage which is cooled by either a passive radiator or a thermoelectric cooler. The MMC has an interface which can accommodate a wide variety of instrument configurations. A shrink fit adapter is incorporated which allows a drop-in instrument integration. The baseline design provides cooling of approximately 1 watt over a 60 to 100 K temperature range and about 0.5 watts from 15 to 60 K for a one year lifetime. For low cooling loads and with use of the optional radiator shield, cooling lifetimes as great as 8 years are predicted.
High power beta electron device - Beyond betavoltaics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayers, William M.; Gentile, Charles A.
Developing watt level power sources with beta emitting radioisotopes has been limited by the inability to utilize high energy (> 100 KeV) beta emitters at high radioisotope loadings without damaging the energy conversion materials. A new type of beta electron power source is described that removes those restrictions. This approach contains the radioisotope in a beta transparent titanium tube and confines beta electrons emitted through the tube wall to spiral trajectories around the tube with an axial magnetic field. The confined beta electrons dissipate energy though multiple interactions with surrounding excimer precursor gas atoms to efficiently generate photons. Photovoltaic cellsmore » convert the photons to electrical power. Since the beta electrons dissipate energy in the excimer precursor gas, the device can be loaded with more than 10 13 Bq of radioisotope to generate 100 milliwatt to watt levels of electrical power without damaging the device materials or degrading its performance. Furthermore, the power source can use a variety of beta radioisotopes and scales by stacking the devices.« less
High power beta electron device - Beyond betavoltaics
Ayers, William M.; Gentile, Charles A.
2017-11-10
Developing watt level power sources with beta emitting radioisotopes has been limited by the inability to utilize high energy (> 100 KeV) beta emitters at high radioisotope loadings without damaging the energy conversion materials. A new type of beta electron power source is described that removes those restrictions. This approach contains the radioisotope in a beta transparent titanium tube and confines beta electrons emitted through the tube wall to spiral trajectories around the tube with an axial magnetic field. The confined beta electrons dissipate energy though multiple interactions with surrounding excimer precursor gas atoms to efficiently generate photons. Photovoltaic cellsmore » convert the photons to electrical power. Since the beta electrons dissipate energy in the excimer precursor gas, the device can be loaded with more than 10 13 Bq of radioisotope to generate 100 milliwatt to watt levels of electrical power without damaging the device materials or degrading its performance. Furthermore, the power source can use a variety of beta radioisotopes and scales by stacking the devices.« less
A new multidimensional diagnostic method for measuring the properties of intense ion beams
NASA Astrophysics Data System (ADS)
Yasuike, Kazuhito; Miyamoto, Shuji; Nakai, Sadao
1996-02-01
A new arrayed pinhole camera (APC) diagnostic method for intense ion beams has been developed. The APC diagnostic technique permits the acquisition of the angular divergences and the ion fluxes of high intensity ion beams, in one shot, with a spatial resolution on the source of better than 1 mm and an effective angular divergence resolution of better than 10 mrad. A prototype time integrated APC has been designed and evaluated. The demonstration experiments have been performed on a Reiden-IV, 1 MV and 1 Ω pulsed power machine [1 T W (tera-watt or trillion watts)]. Proton beams of 0.7 MeV, with a pulse duration of ˜50 ns and an ion current density of about 100 A/cm2, were generated in an applied-Br type ion diode source using paraffin-filled grooves. These experimental results show that the APC can measure nonuniformities in the ion beam intensity generated from the ion source and the dependence of beam angular divergence on ion beam intensity.
High power beta electron device - Beyond betavoltaics.
Ayers, William M; Gentile, Charles A
2018-01-01
Developing watt level power sources with beta emitting radioisotopes has been limited by the inability to utilize high energy (> 100KeV) beta emitters at high radioisotope loadings without damaging the energy conversion materials. A new type of beta electron power source is described that removes those restrictions. The approach contains the radioisotope in a beta transparent titanium tube and confines beta electrons emitted through the tube wall to spiral trajectories around the tube with an axial magnetic field. The confined beta electrons dissipate energy though multiple interactions with surrounding excimer precursor gas atoms to efficiently generate photons. Photovoltaic cells convert the photons to electrical power. Since the beta electrons dissipate energy in the excimer precursor gas, the device can be loaded with more than 10 13 Bq of radioisotope to generate 100 milliwatt to watt levels of electrical power without damaging the device materials or degrading its performance. The power source can use a variety of beta radioisotopes and scales by stacking the devices. Copyright © 2017. Published by Elsevier Ltd.
Development of an air flow thermal balance calorimeter
NASA Technical Reports Server (NTRS)
Sherfey, J. M.
1972-01-01
An air flow calorimeter, based on the idea of balancing an unknown rate of heat evolution with a known rate of heat evolution, was developed. Under restricted conditions, the prototype system is capable of measuring thermal wattages from 10 milliwatts to 1 watt, with an error no greater than 1 percent. Data were obtained which reveal system weaknesses and point to modifications which would effect significant improvements.
Photothermal measurement of optical surface absorption using strain transducers
NASA Astrophysics Data System (ADS)
Leslie, D. H.; Trusty, G. L.
1981-09-01
We discuss the measurement of small optical surface absorption coefficients. A demonstration experiment was performed using a metallurgical strain gauge to measure 488 nm absorption on the surface of a glass plate. A strain of 10 to the minus 8th power resulted from absorption of 0.3 watts. The results are interpreted and the sensitivity of a proposed fiber optic strain gauge is discussed.
Improved detectivity of pyroelectric detectors
NASA Technical Reports Server (NTRS)
Marshall, D. E.; Gelpey, J. C.; Marciniec, J. W.; Chiang, A. M.; Maciolek, R. B.
1978-01-01
High detectivity single-element SBN pyroelectric detectors were fabricated. The theory and technology developments related to improved detector performance were identified and formulated. Improved methods of material characterization, thinning, mounting, blackening and amplifier matching are discussed. Detectors with detectivities of 1.3 x 10 to the 9th power square root of Hz/watt at 1 Hz are reported. Factors limiting performance and recommendations for future work are discussed.
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
A nonlinear q-voter model with deadlocks on the Watts-Strogatz graph
NASA Astrophysics Data System (ADS)
Sznajd-Weron, Katarzyna; Michal Suszczynski, Karol
2014-07-01
We study the nonlinear $q$-voter model with deadlocks on a Watts-Strogats graph. Using Monte Carlo simulations, we obtain so called exit probability and exit time. We determine how network properties, such as randomness or density of links influence exit properties of a model.
47 CFR 22.659 - Effective radiated power limits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... radiated power limits. The purpose of the rules in this section, which limit effective radiated power (ERP... subsequently relocated. (a) Maximum ERP. The ERP of base transmitters must not exceed 100 Watts under any circumstances. The ERP of mobile transmitters must not exceed 60 Watts under any circumstances. (b) Co-channel...
The Watts New? Collection: Columns by the SEI’s Watts Humphrey
2009-11-01
included with all reproductions and derivative works. External use. This document may be reproduced in its entirety, without modification, and freely...all of the buzzwords, would like to act strategically, and talks about being the industry leader, managers are hypnotized by their short-term problems
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-07
... Formerly Known As Core Industries Including Workers Whose Unemployment Insurance (UI) Wages are Reported... names Core Industries and Watts Regulator, Watts Water Technologies. Accordingly, the Department is... known as Core Industries, including workers whose unemployment Insurance (UI) wages are reported through...
A Retrospective of Four Decades of Military Interest in Thermophotovoltaics
NASA Astrophysics Data System (ADS)
Guazzoni, Guido; Matthews, Selma
2004-11-01
Following a short discussion on the origin of Thermophotovoltaic (TPV), this presentation offers a retrospective of the progress and results of the recurrent efforts in TPV conducted in the United States by the Military during the last 40 years. The US Army's interest in TPV, for the development of portable power sources, started a few years after the energy conversion approach was conceived. TPV technology was seen to offer a solution for the Army's need for power in the 10 to 1500 Watt range. The technology offered the means to overcome the limitation of size and weight found in existing commercial power sources, with the additional advantage of silent and multifuel operation. Hence, the Army invested research and development (R&D) funding to investigate TPV feasibility for tactical field application. After an initial decade of continuous research studies by the Army, the support for this technology has experienced cycles of significant efforts interrupted by temporary waiting periods to allow this technology to further mature. Over the last four decades, several TPV proof of concept systems were developed. The results of their testing and evaluation have demonstrated the feasibility of the technology for development of power sources with output of several watts to a few hundreds watts. To date, the results have not been found to adequately demonstrate the applicability of TPV to the development of military power generators with output above 500 watts. TPV power sources have not been developed yet for Army field use or troop testing. The development risk is still considered to be moderate-to-high since practical-size systems that go beyond the laboratory test units have not been designed, constructed, tested. The greatest need is for system development, along with concurrent continued component development and improvement. The Defense Advanced Research Project Agency (DARPA) support for TPV R&D effort has been drastically reduced. The Army is still pursuing a 500watt TPV unit demonstrator. No further collaboration among DARPA, Army, NASA is contemplated, which seems indicative of the beginning of a new period of waiting for additional maturing of this technology. The Army's assessment about the viability of TPV for integrated systems indicates that the technology will require a few more years of development. However, at this time, for the completion of component and system development, a strong effort is needed in the private sector. The achievement of the necessary ruggedness for some critical components, acceptable overall efficiency, and system thermal management, is essential for a new, strong restart of TPV effort by the Military.
Rotacor: a new rotary blood pump.
Margreiter, R; Schwab, W; Klima, G; Koller, J; Baum, M; Dietrich, H; Hager, J; Königsrainer, A
1990-01-01
A new rotary blood pump was tested in calves for 6 hr. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotates on an eccentric shaft in a trochoidal path, thus creating a gap seal. The pump is driven by a water-cooled DC motor. For right ventricular assist, a cannula was inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assist. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 3 L at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hr, when it started to chop again; after 6 hr it was 16 mg/dl. From these preliminary results it is concluded that this new type of blood pump may be suitable as a circulatory assist device.
Powering prolonged hydrothermal activity inside Enceladus
NASA Astrophysics Data System (ADS)
Choblet, Gaël; Tobie, Gabriel; Sotin, Christophe; Běhounková, Marie; Čadek, Ondřej; Postberg, Frank; Souček, Ondřej
2017-12-01
Geophysical data from the Cassini spacecraft imply the presence of a global ocean underneath the ice shell of Enceladus1, only a few kilometres below the surface in the South Polar Terrain2-4. Chemical analyses indicate that the ocean is salty5 and is fed by ongoing hydrothermal activity6-8. In order to explain these observations, an abnormally high heat power (>20 billion watts) is required, as well as a mechanism to focus endogenic activity at the south pole9,10. Here, we show that more than 10 GW of heat can be generated by tidal friction inside the unconsolidated rocky core. Water transport in the tidally heated permeable core results in hot narrow upwellings with temperatures exceeding 363 K, characterized by powerful (1-5 GW) hotspots at the seafloor, particularly at the south pole. The release of heat in narrow regions favours intense interaction between water and rock, and the transport of hydrothermal products from the core to the plume sources. We are thus able to explain the main global characteristics of Enceladus: global ocean, strong dissipation, reduced ice-shell thickness at the south pole and seafloor activity. We predict that this endogenic activity can be sustained for tens of millions to billions of years.
Electrostatic Inflation of Membrane Space Structures
NASA Astrophysics Data System (ADS)
Stiles, Laura A.
Membrane space structures provide a lightweight and cost effective alternative to traditional mechanical systems. The low-mass and high deployed-to-stored volume ratios allow for larger structures to be launched, expanding on-orbit science and technology capabilities. This research explores a novel method for deployment of membrane space structures using electrostatic pressure as the inflation mechanism. Applying electric charge to a layered gossamer structure provides an inflationary pressure due to the repulsive electrostatic forces between the charged layers. The electrostatic inflation of membrane structures (EIMS) concept is particularly applicable to non-precision structures such as sunshields or drag de-orbiting devices. This research addresses three fundamental topics: necessary conditions for EIMS in a vacuum, necessary conditions for EIMS in a plasma, and charging methods. Vacuum demonstrations show that less than 10 kiloVolts are required for electrostatic inflation of membrane structures in 1-g. On-orbit perturbation forces can be much smaller, suggesting feasible voltage requirements. Numerical simulation enables a relationship between required inflation pressure (to offset disturbances) and voltage. 100's of Volts are required for inflation in geosynchronous orbits (GEO) and a few kiloVolts in low Earth orbit (LEO). While GEO plasma has a small impact on the EIMS performance, Debye shielding at LEO reduces the electrostatic pressure. The classic Debye shielding prediction is far worse than actual shielding, raising the `effective' Debye length to the meter scale in LEO, suggesting feasibility for EIMS in LEO. Charged particle emission and remote charging methods are explored as inflation mechanisms. Secondary electron emission characteristics of EIMS materials were determined experimentally. Nonlinear fits to the Sternglass curve determined a maximum yield of 1.83 at 433 eV for Aluminized Kapton and a maximum yield of 1.78 at 511 eV for Aluminized Mylar. Remote charging was demonstrated to -500 V with a 5 keV electron beam. Charge emission power levels are below 1 Watt in GEO and from 10's of Watt to a kiloWatt in LEO.
Investigation of test methods, material properties, and processes for solar cell encapsulants
NASA Technical Reports Server (NTRS)
1984-01-01
Photovoltaic (PV) modules consist of a string of electrically interconnected silicon solar cells capable of producing practical quantities of electrical power when exposed to sunlight. To insure high reliability and long term performance, the functional components of the solar cell module must be adequately protected from the environment by some encapsulation technique. The encapsulation system must provide mechanical support for the cells and corrosion protection for the electrical components. The goal of the program is to identify and develop encapsulation systems consistent with the PV module operating requirements of 30 year life and a target cost of $0.70 per peak watt ($70 per square meter) (1980 dollars). Assuming a module efficiency of ten percent, which is equivalent to a power output of 100 watts per square meter in midday sunlight, the capital cost of the modules may be calculated to be $70.00 per square meter. Out of this cost goal, only 20 percent is available for encapsulation due to the high cost of the cells, interconnects, and other related components. The encapsulation cost allocation may then be stated as $14.00 per square meter, included all coatings, pottant and mechanical supports for the cells.
Photovoltaic frequency–watt curve design for frequency regulation and fast contingency reserves
Johnson, Jay; Neely, Jason C.; Delhotal, Jarod J.; ...
2016-09-02
When renewable energy resources are installed in electricity grids, they typically increase generation variability and displace thermal generator control action and inertia. Grid operators combat these emerging challenges with advanced distributed energy resource (DER) functions to support frequency and provide voltage regulation and protection mechanisms. This paper focuses on providing frequency reserves using autonomous IEC TR 61850-90-7 pointwise frequency-watt (FW) functions that adjust DER active power as a function of measured grid frequency. The importance of incorporating FW functions into a fleet of photovoltaic (PV) systems is demonstrated in simulation. Effects of FW curve design, including curtailment, deadband, and droop,more » were analyzed against performance metrics using Latin hypercube sampling for 20%, 70%, and 120% PV penetration scenarios on the Hawaiian island of Lanai. Finally, to understand the financial implications of FW functions to utilities, a performance function was defined based on monetary costs attributable to curtailed PV production, load shedding, and generator wear. An optimization wrapper was then created to find the best FW function curve for each penetration level. Lastly, it was found that in all cases, the utility would save money by implementing appropriate FW functions.« less
Miniature Fuel Processors for Portable Fuel Cell Power Supplies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holladay, Jamie D.; Jones, Evan O.; Palo, Daniel R.
2003-06-02
Miniature and micro-scale fuel processors are discussed. The enabling technologies for these devices are the novel catalysts and the micro-technology-based designs. The novel catalyst allows for methanol reforming at high gas hourly space velocities of 50,000 hr-1 or higher, while maintaining a carbon monoxide levels at 1% or less. The micro-technology-based designs enable the devices to be extremely compact and lightweight. The miniature fuel processors can nominally provide between 25-50 watts equivalent of hydrogen which is ample for soldier or personal portable power supplies. The integrated processors have a volume less than 50 cm3, a mass less than 150 grams,more » and thermal efficiencies of up to 83%. With reasonable assumptions on fuel cell efficiencies, anode gas and water management, parasitic power loss, etc., the energy density was estimated at 1700 Whr/kg. The miniature processors have been demonstrated with a carbon monoxide clean-up method and a fuel cell stack. The micro-scale fuel processors have been designed to provide up to 0.3 watt equivalent of power with efficiencies over 20%. They have a volume of less than 0.25 cm3 and a mass of less than 1 gram.« less
Spark ignited turbulent flame kernel growth. Annual report, January--December 1991
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santavicca, D.A.
1994-06-01
An experimental study of the effect of spark power on the growth rate of spark-ignited flame kernels was conducted in a turbulent flow system at 1 atm, 300 K conditions. All measurements were made with premixed, propane-air at a fuel/air equivalence ratio of 0.93, with 0%, 8% or 14% dilution. Two flow conditions were studied: a low turbulence intensity case with a mean velocity of 1.25 m/sec and a turbulence intensity of 0.33 m/sec, and a high turbulence intensity case with a mean velocity of 1.04 m/sec and a turbulence intensity of 0.88 m/sec. The growth of the spark-ignited flamemore » kernel was recorded over a time interval from 83 {mu}sec to 20 msec following the start of ignition using high speed laser shadowgraphy. In order to evaluate the effect of ignition spark power, tests were conducted with a long duration (ca 4 msec) inductive discharge ignition system with an average spark power of ca 14 watts and two short duration (ca 100 nsec) breakdown ignition systems with average spark powers of ca 6 {times} 10{sup 4} and ca 6 {times} 10{sup 5} watts. The results showed that increased spark power resulted in an increased growth rate, where the effect of short duration breakdown sparks was found to persist for times of the order of milliseconds. The effectiveness of increased spark power was found to be less at high turbulence and high dilution conditions. Increased spark power had a greater effect on the 0--5 mm burn time than on the 5--13 mm burn time, in part because of the effect of breakdown energy on the initial size of the flame kernel. And finally, when spark power was increased by shortening the spark duration while keeping the effective energy the same there was a significant increase in the misfire rate, however when the spark power was further increased by increasing the breakdown energy the misfire rate dropped to zero.« less
NASA Technical Reports Server (NTRS)
Koch, Dorothy; Bauer, Susanne E.; Del Genio, Anthony; Faluvegi, Greg; McConnell, Joseph R.; Menon, Surabi; Miller, Ronald L.; Rind, David; Ruedy, Reto; Schmidt, Gavin A.;
2011-01-01
The authors simulate transient twentieth-century climate in the Goddard Institute for Space Studies (GISS) GCM, with aerosol and ozone chemistry fully coupled to one another and to climate including a full dynamic ocean. Aerosols include sulfate, black carbon (BC), organic carbon, nitrate, sea salt, and dust. Direct and BC snow-albedo radiative effects are included. Model BC and sulfur trends agree fairly well with records from Greenland and European ice cores and with sulfur deposition in North America; however, the model underestimates the sulfur decline at the end of the century in Greenland. Global BC effects peak early in the century (1940s); afterward the BC effects decrease at high latitudes of the Northern Hemisphere but continue to increase at lower latitudes. The largest increase in aerosol optical depth occurs in the middle of the century (1940s-80s) when sulfate forcing peaks and causes global dimming. After this, aerosols decrease in eastern North America and northern Eurasia leading to regional positive forcing changes and brightening. These surface forcing changes have the correct trend but are too weak. Over the century, the net aerosol direct effect is -0.41 Watts per square meter, the BC-albedo effect is -0.02 Watts per square meter, and the net ozone forcing is +0.24 Watts per square meter. The model polar stratospheric ozone depletion develops, beginning in the 1970s. Concurrently, the sea salt load and negative radiative flux increase over the oceans around Antarctica. Net warming over the century is modeled fairly well; however, the model fails to capture the dynamics of the observedmidcentury cooling followed by the late century warming.Over the century, 20% of Arctic warming and snow ice cover loss is attributed to the BC albedo effect. However, the decrease in this effect at the end of the century contributes to Arctic cooling. To test the climate responses to sulfate and BC pollution, two experiments were branched from 1970 that removed all pollution sulfate or BC. Averaged over 1970-2000, the respective radiative forcings relative to the full experiment were +0.3 and -0.3 Watts per square meter; the average surface air temperature changes were +0.2 degrees and -0.03 C. The small impact of BC reduction on surface temperature resulted from reduced stability and loss of low-level clouds.
Development of an engineering model traveling wave tube amplifier for space communication systems
NASA Technical Reports Server (NTRS)
Eallonardo, C. M.; Songli, J.; Basiulis, A.
1972-01-01
A design has been made of a 100 watt traveling-wave tube amplifier for use in space communication applications. The features of very high overall efficiency and heat rejection of waste heat at low thermal densities were predominant in the design concept. The design concept was proven by building a series of tubes, operating at efficiencies up to 50%. These tubes utilized heat pipe cooling and heat distribution such that 150 watts of waste heat was rejected at a density of less than 1.5 watts per square inch. A power supply to convert a 28 volt primary line of the needs of the TWT was built and operated at 85% efficiency.
Constructing a Watts-Strogatz network from a small-world network with symmetric degree distribution.
Menezes, Mozart B C; Kim, Seokjin; Huang, Rongbing
2017-01-01
Though the small-world phenomenon is widespread in many real networks, it is still challenging to replicate a large network at the full scale for further study on its structure and dynamics when sufficient data are not readily available. We propose a method to construct a Watts-Strogatz network using a sample from a small-world network with symmetric degree distribution. Our method yields an estimated degree distribution which fits closely with that of a Watts-Strogatz network and leads into accurate estimates of network metrics such as clustering coefficient and degree of separation. We observe that the accuracy of our method increases as network size increases.
CrossTalk: The Journal of Defense Software Engineering. Volume 20, Number 2
2007-02-01
article is to show that when an organization is already doing competent project management, the effort to benchmark that capability by using CMMI is...process-improvement evolution. by Watts S . Humphrey, Dr. Michael D. Konrad, James W. Over, and William C. Peterson The ImprovAbility Model This model helps...17 23 29 3 12 16 22 30 31 D ep ar t m e n t s From the Sponsor Call For Articles Ad More Online From CrossTalk Coming Events SSTC 2007 BackTalk CMMI
A Compendium of Portage Studies
1982-02-01
M = 1.5W + 2.0(W+L)(L/W)2 + E(W+L)(1.5V2 + 0.35VG) (1) where M = metabolic cost (watts) W = subject weight, nude (kg) L = external load (kg) E...footing factor V = velocity ( m /sec) G = grade or slope (%) While it may not always result in an accurate prediction, Formula 1 does incorporate...Randall, R.B. Ray, S.N. Redfearn, J.W.T. Reid, A.M. Renbourne, E.T. Ress, M . Richardson, D.T. Roy, B.N. Saha, P.N. Sanders, J.H. Sen, R.N. Sen
Performance of one hundred watt HVM LPP-EUV source
NASA Astrophysics Data System (ADS)
Mizoguchi, Hakaru; Nakarai, Hiroaki; Abe, Tamotsu; Nowak, Krzysztof M.; Kawasuji, Yasufumi; Tanaka, Hiroshi; Watanabe, Yukio; Hori, Tsukasa; Kodama, Takeshi; Shiraishi, Yutaka; Yanagida, Tatsuya; Soumagne, Georg; Yamada, Tsuyoshi; Yamazaki, Taku; Okazaki, Shinji; Saitou, Takashi
2015-03-01
We have been developing CO2-Sn-LPP EUV light source which is the most promising solution as the 13.5nm high power light source for HVM EUVL. Unique and original technologies such as: combination of pulsed CO2 laser and Sn droplets, dual wavelength laser pulses shooting, and mitigation with magnetic field, have been developed in Gigaphoton Inc. The theoretical and experimental data have clearly showed the advantage of our proposed strategy. Based on these data we are developing first practical source for HVM - "GL200E". This data means 250W EUV power will be able to realize around 20kW level pulsed CO2 laser. We have reported engineering data from our recent test such around 43W average clean power, CE=2.0%, with 100kHz operation and other data 19). We have already finished preparation of higher average power CO2 laser more than 20kW at output power cooperate with Mitsubishi Electric Corporation 14). Recently we achieved 92W with 50kHz, 50% duty cycle operation 20). We have reported component technology progress of EUV light source system. We report promising experimental data and result of simulation of magnetic mitigation system in Proto #1 system. We demonstrated several data with Proto #2 system: (1) emission data of 140W in burst under 70kHz 50% duty cycle during 10 minutes. (2) emission data of 118W in burst under 60kHz 70% duty cycle during 10 minutes. (3) emission data of 42W in burst under 20kHz 50% duty cycle (10000pls/0.5ms OFF) during 3 hours (110Mpls). Also we report construction of Pilot #1 system. Final target is week level operation with 250W EUV power with CE=4%, more than 27kW CO2 laser power by the end of Q2 of 2015.
47 CFR 90.542 - Broadband transmitting power limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Antenna height (AAT) in meters(feet) Effective radiated power (ERP)(watts) Above 1372 (4500) 65 Above 1220... Bandwidth of 1 MHz or Less Antenna height (AAT) in meters(feet) Effective radiated power (ERP)(watts) Above... (3000) To 1067 (3500) 200 Above 763 (2500) To 915 (3000) 280 Above 610 (2000) To 763 (2500) 400 Above...
24 CFR 3280.707 - Heat producing appliances.
Code of Federal Regulations, 2014 CFR
2014-04-01
... have a flue loss of not more than 25 percent, and a thermal efficiency of not less than that specified... efficiency. (1) All automatic electric storage water heaters installed in manufactured homes shall have a standby loss not exceeding 43 watts/meter2 (4 watts/ft2) of tank surface area. The method of test for...
Dealing with failed deregulation: what would price c. Watts do?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rothkopf, Michael H.
2007-08-15
There has been much thought given to ways that might fix deregulated markets, and there is still no agreement on the correct fix. The once-pseudonymous Price C. Watts thinks it is time to think seriously about ways to reregulate where deregulation has failed. Here are some steps to get us there. (author)
The Watts Premier WP-4V POU drinking water treatment system was tested for removal of aldicarb, benzene, cadmium, carbofuran, cesium, chloroform, dichlorvos, dicrotophos, fenamiphos, mercury, mevinphos, oxamyl, strontium, and strychnine. The WP-4V employs a reverse osmosis (RO) m...
Mismatch Repair Balances Leading and Lagging Strand DNA Replication Fidelity
2012-10-11
mismatched base stacks with a conserved phenylalanine in Msh6, and/or (iii) DNA flexibility, since MutSa-bound mismatched DNA is kinked, and a...AB, Watt DL , Watts BE, et al. (2010) Genome instability due to ribonucleotide incorporation into DNA. Nat Chem Biol 6: 774–781. 24. Poloumienko A
Efect of tri-species chromosome shuffling on agronomic and fiber traits in Upland cotton
USDA-ARS?s Scientific Manuscript database
Gossypium barbadense (L.), G. tomentosum (Seem.), G. mustelinum (Watt.) and G. darwinii (Watt.) are in the primary gene pool of Upland cotton (G. hirsutum). They share a common chromosome number (2n=52), similar AD-genome architecture, and form reasonably fertile F1 hybrids. However, reduced transm...
An analytical algorithm for 3D magnetic field mapping of a watt balance magnet
NASA Astrophysics Data System (ADS)
Fu, Zhuang; Zhang, Zhonghua; Li, Zhengkun; Zhao, Wei; Han, Bing; Lu, Yunfeng; Li, Shisong
2016-04-01
A yoke-based permanent magnet, which has been employed in many watt balances at national metrology institutes, is supposed to generate strong and uniform magnetic field in an air gap in the radial direction. However, in reality the fringe effect due to the finite height of the air gap will introduce an undesired vertical magnetic component to the air gap, which should either be measured or modeled towards some optimizations of the watt balance. A recent publication, i.e. Li et al (2015 Metrologia 52 445), presented a full field mapping method, which in theory will supply useful information for profile characterization and misalignment analysis. This article is an additional material of Li et al (2015 Metrologia 52 445), which develops a different analytical algorithm to represent the 3D magnetic field of a watt balance magnet based on only one measurement for the radial magnetic flux density along the vertical direction, B r (z). The new algorithm is based on the electromagnetic nature of the magnet, which has a much better accuracy.
Varona, Omar de; Steinke, Michael; Neumann, Jörg; Kracht, Dietmar
2018-06-01
Emerging applications, such as gravitational wave astronomy, demand single-frequency lasers with diffraction-limited emission at 1.5 μm. Fiber amplifiers have greatly evolved to fulfill these requirements. Hundreds of watts are feasible using large-mode-area and specialty fibers. However, their application in a few watts to tens of watts in monolithic systems is unnecessarily complex due to the poor commercial availability of fiber components and standard integration procedures. In this Letter we propose and experimentally demonstrate a novel and simple method to amplify single-frequency signals at 1.5 μm up to tens of watts by core-pumping single-mode Er 3+ :Yb 3+ fiber amplifiers at 1018 nm. The proof-of-principle system is tested with different active fibers, lengths, and seed power levels. Over 11 W with an efficiency of more than 48% versus launched power is achieved. Additionally, performance degradation during operation was observed for which photodarkening due to P1 defects might be an explanation.
Coastal Fishermen as Lifesavers While Sailing at High Speed: A Crossover Study
Fungueiriño-Suárez, Ramón; Martínez-Isasi, Santiago; Fernández-Méndez, Felipe; González-Salvado, Violeta; Navarro-Patón, Rubén; Rodríguez-Núñez, Antonio
2018-01-01
Purpose Starting basic cardiopulmonary resuscitation (CPR) early improves survival. Fishermen are the first bystanders while at work. Our objective was to test in a simulated scenario the CPR quality performed by fishermen while at port and while navigating at different speeds. Methods Twenty coastal fishermen were asked to perform 2 minutes of CPR (chest compressions and mouth-to-mouth ventilations) on a manikin, in three different scenarios: (A) at port on land, (B) on the boat floor sailing at 10 knots, and (C) sailing at 20 knots. Data was recorded using quality CPR software, adjusted to current CPR international guidelines. Results The quality of CPR (QCPR) was significantly higher at port (43% ± 10) than sailing at 10 knots (30% ± 15; p = 0.01) or at 20 knots (26% ± 12; p = 0.001). The percentage of ventilation that achieved some lung insufflation was also significantly higher when CPR was done at port (77% ± 14) than while sailing at 10 knots (59% ± 18) or 20 knots (57% ± 21) (p = 0.01). Conclusion In the event of drowning or cardiac arrest on a small boat, fishermen should immediately start basic CPR and navigate at a relatively high speed to the nearest port if the sea conditions are safe. PMID:29854735
Code of Federal Regulations, 2011 CFR
2011-01-01
... power (i.e., watts) consumed as the time series integral of the power consumed over a 1-hour test period...) consumed as the time series integral of the power consumed over a 1-hour test period, divided by the period...-maintenance mode and standby mode over time periods defined in the test procedure. b. Active mode is the...
Mining Videos for Features that Drive Attention
2015-04-01
Psychology & Neuroscience Graduate Program, University of Southern California, 3641 Watt Way, HNB 10, Los Angeles, CA 90089, USA e-mail: itti@usc.edu...challenging question in neuroscience . Since the onset of visual experience, a human or animal begins to form a subjective percept which, depending on...been added based on neuroscience discoveries of mechanisms of vision in the brain as well as useful features based on computer vision. Figure14.1 illus
Microfabricated Millimeter-Wave High-Power Vacuum Electronic Amplifiers
2015-01-01
Applications filed 2012). In spite of the challenges, high power sources of electromagnetic radiation are needed in the mmW bands for advanced DoD...Research Laboratory is demonstrating and developing millimeter-wave vacuum electronic traveling wave tube amplifiers at W- and G- band in the 10’ s to 100... s of watts power range at several percent instantaneous bandwidth. Keywords: Traveling wave tube; millimeter wave; vacuum electron device
High-Altitude, Long-Endurance UAVs vs. Satellites: Potential Benefits for U.S. Army Applications
2009-05-01
Refractive Imaging System ....... Point Spread Function ......................... Transmission Characteristics of the Earth’s Atmosphere ...... Scanning...Angle in degrees Commwt Communications Payload Weight p Angular Radius of the Earth in degrees Palbedo Earth’s Albedo Patm Atmospheric Density in...femto-watt (10-15) FY Fiscal Year Gbps Gigabits per Second GBS Global Broadcast System GCS Ground Control Station GEO Geosynchronous Earth Orbit
2015-09-21
vehicles, environmental sensor networks, distributed hydrologic modeling, vegetation dynamics, soil moisture, evapotranspiration , remote sensing, North...Received Paper 1.00 5.00 3.00 8.00 9.00 E. Vivoni, J. Rodriguez, C. Watts. On the spatiotemporal variability of soil moisture and evapotranspiration ...Vegetation Impacts on Evapotranspiration and Its Partitioning at the Catchment Scale during SMEX04–NAME, Journal of Hydrometeorology, (10 2012
Code of Federal Regulations, 2010 CFR
2010-01-01
... power (i.e., watts) consumed as the time series integral of the power consumed over a 1-hour test period...) consumed as the time series integral of the power consumed over a 1-hour test period, divided by the period...-maintenance mode and standby mode over time periods defined in the test procedure. b. Active mode is the...
Planck Constant Determination from Power Equivalence
NASA Astrophysics Data System (ADS)
Newell, David B.
2000-04-01
Equating mechanical to electrical power links the kilogram, the meter, and the second to the practical realizations of the ohm and the volt derived from the quantum Hall and the Josephson effects, yielding an SI determination of the Planck constant. The NIST watt balance uses this power equivalence principle, and in 1998 measured the Planck constant with a combined relative standard uncertainty of 8.7 x 10-8, the most accurate determination to date. The next generation of the NIST watt balance is now being assembled. Modification to the experimental facilities have been made to reduce the uncertainty components from vibrations and electromagnetic interference. A vacuum chamber has been installed to reduce the uncertainty components associated with performing the experiment in air. Most of the apparatus is in place and diagnostic testing of the balance should begin this year. Once a combined relative standard uncertainty of one part in 10-8 has been reached, the power equivalence principle can be used to monitor the possible drift in the artifact mass standard, the kilogram, and provide an accurate alternative definition of mass in terms of fundamental constants. *Electricity Division, Electronics and Electrical Engineering Laboratory, Technology Administration, U.S. Department of Commerce. Contribution of the National Institute of Standards and Technology, not subject to copyright in the U.S.
Semiconductor Laser Diode Pumps for Inertial Fusion Energy Lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deri, R J
2011-01-03
Solid-state lasers have been demonstrated as attractive drivers for inertial confinement fusion on the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) and at the Omega Facility at the Laboratory for Laser Energetics (LLE) in Rochester, NY. For power plant applications, these lasers must be pumped by semiconductor diode lasers to achieve the required laser system efficiency, repetition rate, and lifetime. Inertial fusion energy (IFE) power plants will require approximately 40-to-80 GW of peak pump power, and must operate efficiently and with high system availability for decades. These considerations lead to requirements on the efficiency, price, and productionmore » capacity of the semiconductor pump sources. This document provides a brief summary of these requirements, and how they can be met by a natural evolution of the current semiconductor laser industry. The detailed technical requirements described in this document flow down from a laser ampl9ifier design described elsewhere. In brief, laser amplifiers comprising multiple Nd:glass gain slabs are face-pumped by two planar diode arrays, each delivering 30 to 40 MW of peak power at 872 nm during a {approx} 200 {micro}s quasi-CW (QCW) pulse with a repetition rate in the range of 10 to 20 Hz. The baseline design of the diode array employs a 2D mosaic of submodules to facilitate manufacturing. As a baseline, they envision that each submodule is an array of vertically stacked, 1 cm wide, edge-emitting diode bars, an industry standard form factor. These stacks are mounted on a common backplane providing cooling and current drive. Stacks are conductively cooled to the backplane, to minimize both diode package cost and the number of fluid interconnects for improved reliability. While the baseline assessment in this document is based on edge-emitting devices, the amplifier design does not preclude future use of surface emitting diodes, which may offer appreciable future cost reductions and increased reliability. The high-level requirements on the semiconductor lasers involve reliability, price points on a price-per-Watt basis, and a set of technical requirements. The technical requirements for the amplifier design in reference 1 are discussed in detail and are summarized in Table 1. These values are still subject to changes as the overall laser system continues to be optimized. Since pump costs can be a significant fraction of the overall laser system cost, it is important to achieve sufficiently low price points for these components. At this time, the price target for tenth-of-akind IFE plant is $0.007/Watt for packaged devices. At this target level, the pumps account for approximately one third of the laser cost. The pump lasers should last for the life of the power plant, leading to a target component lifetime requirement of roughly 14 Ghosts, corresponding to a 30 year plant life and 15 Hz repetition rate. An attractive path forward involes pump operation at high output power levels, on a Watts-per-bar (Watts/chip) basis. This reduces the cost of pump power (price-per-Watt), since to first order the unit price does not increase with power/bar. The industry has seen a continual improvement in power output, with current 1 cm-wide bars emitting up to 500 W QCW (quasi-continuous wave). Increased power/bar also facilitates achieving high irradiance in the array plane. On the other hand, increased power implies greater heat loads and (possibly) higher current drive, which will require increased attention to thermal management and parasitic series resistance. Diode chips containing multiple p-n junctions and quantum wells (also called nanostack structures) may provide an additional approach to reduce the peak current.« less
Research on imaging spectrometer using LC-based tunable filter
NASA Astrophysics Data System (ADS)
Shen, Zhixue; Li, Jianfeng; Huang, Lixian; Luo, Fei; Luo, Yongquan; Zhang, Dayong; Long, Yan
2012-09-01
A liquid crystal tunable filter (LCTF) with large aperture is developed using PDLC liquid crystal. A small scale imaging spectrometer is established based on this tunable filter. This spectrometer can continuously tuning, or random-access selection of any wavelength in the visible and near infrared (VNIR) band synchronized with the imaging processes. Notable characteristics of this spectrometer include the high flexibility control of its operating channels, the image cubes with high spatial resolution and spectral resolution and the strong ability of acclimation to environmental temperature. The image spatial resolution of each tuning channel is almost near the one of the same camera without the LCTF. The spectral resolution is about 20 nm at 550 nm. This spectrometer works normally under 0-50°C with a maximum power consumption of 10 Watts (with exclusion of the storage module). Due to the optimization of the electrode structure and the driving mode of the Liquid Crystal cell, the switch time between adjacent selected channels can be reduced to 20 ms or even shorter. Spectral imaging experiments in laboratory are accomplished to verify the performance of this spectrometer, which indicate that this compact imaging spectrometer works reliably, and functionally. Possible applications of this imaging spectrometer include medical science, protection of historical relics, criminal investigation, disaster monitoring and mineral detection by remote sensing.
Power consumption analysis DBD plasma ozone generator
NASA Astrophysics Data System (ADS)
Nur, M.; Restiwijaya, M.; Muchlisin, Z.; Susan, I. A.; Arianto, F.; Widyanto, S. A.
2016-11-01
Studies on the consumption of energy by an ozone generator with various constructions electrodes of dielectric barrier discharge plasma (DBDP) reactor has been carried out. This research was done to get the configuration of the reactor, that is capable to produce high ozone concentrations with low energy consumption. BDBP reactors were constructed by spiral- cylindrical configuration, plasma ozone was generated by high voltage AC voltage up to 25 kV and maximum frequency of 23 kHz. The reactor consists of an active electrode in the form of a spiral-shaped with variation diameter Dc, and it was made by using copper wire with diameter Dw. In this research, we variated number of loops coil windings N as well as Dc and Dw. Ozone concentrations greater when the wire's diameter Dw and the diameter of the coil windings applied was greater. We found that impedance greater will minimize the concentration of ozone, in contrary to the greater capacitance will increase the concentration of ozone. The ozone concentrations increase with augmenting of power. Maximum power is effective at DBD reactor spiral-cylinder is on the Dc = 20 mm, Dw = 1.2 mm, and the number of coil windings N = 10 loops with the resulting concentration is greater than 20 ppm and it consumes energy of 177.60 watts
A Simple Watt Balance for the Absolute Determination of Mass
ERIC Educational Resources Information Center
Quinn, Terry; Quinn, Lucas; Davis, Richard
2013-01-01
A watt balance is an electromechanical device that allows a mass to be determined in terms of measurable electrical and mechanical quantities, themselves traceable to the fundamental constants of physics. International plans are well advanced to redefine the unit of mass, the kilogram, in terms of a fixed numerical value for the Planck constant. A…
Confronting the Nation's Urban Crisis: From Watts (1965) to South Central Los Angeles (1992).
ERIC Educational Resources Information Center
Peterson, George E.; And Others
What has been learned about making cities better since civil disturbances first arose in American cities is summarized, and guidelines are offered for constructing an urban agenda for improvement. In some respects the country has made real progress since the Watts riots, but in other areas, conditions are unambiguously worse, with increasing…
2010-11-30
Erdos- Renyi -Gilbert random graph [Erdos and Renyi , 1959; Gilbert, 1959], the Watts-Strogatz “small world” framework [Watts and Strogatz, 1998], and the...2003). Evolution of Networks. Oxford University Press, USA. Erdos, P. and Renyi , A. (1959). On Random Graphs. Publications Mathematicae, 6 290–297
The Watts Premier WP-4V four-stage POU RO system was tested for removal of bacteria and viruses at NSF’s Drinking Water Treatment Systems Laboratory. Five systems were challenged with the bacteriophage viruses fr and MS2, and the bacteria Brevundimonas diminutaEM. The ...
The Watts Premier M-2400 POE RO Drinking Water Treatment System was tested at the NSF Drinking Water Treatment Systems Laboratory for removal of the viruses fr and MS2, the bacteria Brevundimonas diminuta, and chemicals aldicarb, benzene, cadmium, carbofuran, cesium, chl...
Elijah Watt Sells Award: A Study of Previous Winners
ERIC Educational Resources Information Center
Husted, Susan; Pinto, Joann; Romero, Silvia
2013-01-01
This paper reports the results of a survey of winners of the Elijah Watt Sells award. We ask them about the determinants of their success, which might be useful to other students preparing for the CPA exam. The winners graduated from different universities, not necessarily the ones ranked top, and almost all of them participated in a review…
An Interview with Toni Watt, 2004 Award Winner
ERIC Educational Resources Information Center
Journal of Chemical Education, 2004
2004-01-01
Toni Austin Watt, the winner of the 2004 James Bryant Conant Award in High School Chemistry Teaching says that she was always an average student and had to invest more time in improving her skills and getting experiences, thus she is exhilarated that her efforts have received such acclaim and is honored that people thought her efforts were…
47 CFR 80.80 - Operating controls for ship stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-162 MHz bands, reducing power output to one watt or less in accordance with § 80.215(e). 1 1 Ship... automatically reduce the carrier power to one watt or less when turned to the frequency 156.375 MHz or 156.650..., 1997, must automatically reduce power as described above. A manual override device must be provided...
Doing it All: Security Forces--The USAF Coin Force
2009-06-01
Joseph L. III, Capt William M. Dains , and Capt David T. Watts, “Air Force Breaks New Ground at Camp Bucca, Iraq.” Military Police Bulletin, PB 19- 05-2...October 2005, http://www.wood.army.mil/MPBULLETIN/pdfs/Oct%2005/ Romano- Dains -Watts.pdf (accessed 30 Dec 08). SAFESIDE: Final Report. US Air Force
NASA Technical Reports Server (NTRS)
Leipold, M. H.
1978-01-01
A variety of techniques may be used for photovoltaic energy systems. Concentrated or not concentrated sunlight may be employed, and a number of materials can be used, including silicon, gallium arsenide, cadmium sulfide, and cadmium telluride. Most of the experience, however, has been obtained with silicon cells employed without sunlight concentration. An industrial base exists at present for producing solar cells at a price in the range from $15 to $30 per peak watt. A major federal program has the objective to reduce the price of power provided by silicon solar systems to approximately $1 per peak watt in the early 1980's and $0.50 per watt by 1986. The approaches considered for achieving this objective are discussed.
Preliminary investigation of a sealed, remotely activated silver-zinc battery
NASA Technical Reports Server (NTRS)
Wheat, C. G.
1977-01-01
Methods necessary to provide a remotely activated, silver zinc battery capable of an extended activated stand while in a sealed condition were investigated. These requirements were to be accomplished in a battery package demonstrating an energy density of at least 35 watt hours per pound. Several methods of gas suppression were considered in view of the primary nature of this unit and utilized the electroplated dendritic zinc electrode. Amalgamation of the electrode provided the greatest suppression of gas at the zinc electrode. The approach to extending the activated stand capability of the remotely activated battery was through evaluation of three basic methods of remote, multi-cell activation; 1) the electrolyte manifold, 2) the gas manifold and 3) the individual cell. All three methods of activation can be incorporated into units which will meet the minimum energy density requirement.
Tumorigenicity of fine man-made fibers after intratracheal administrations to hamsters.
Adachi, S; Takemoto, K; Kimura, K
1991-02-01
Six types of man-made fibers were administered intratracheally (2.0 mg/animal each a week, for 5 weeks; total 10 mg/animal) to female Syrian hamsters that were observed histologically for 2 years after administration. The fibers were rock wool [average diameter (D) = 6.1 microns, average length (L) = 296 microns], fiberglass (D = 0.65 microns, L = 16.8 microns), potassium titanate fiber (D = 0.36 microns, L = 7.17 microns), calcium sulfate fiber (D = 1.0 microns, L = 17.8 microns), basic magnesium sulfate fiber (D = 0.45 microns, L = 22.4 microns), and metaphosphate fiber (D = 2.38 microns, L = 64.1 microns). Tumors were observed in hamsters that had received basic magnesium sulfate fiber (9/20), metaphosphate fiber (6/20), calcium sulfate fiber (3/20), and fiberglass (2/20) but not in the control, rock wool, or potassium titanate fiber groups. The primary sites of the tumors were not only in the pleural cavity but also in the intracelial organs, kidney, adrenal gland, bladder, and uterus. Only a few of the tumors were identified as mesotheliomas by histological examination. In addition to neoplastic lesions, fibrosis, pleural thickening, and chronic inflammatory changes in the lungs were observed in the hamsters, but these changes appeared too mild to foster a pneumoconiosis such as asbestosis.
Small Stirling dynamic isotope power system for robotic space missions
NASA Technical Reports Server (NTRS)
Bents, D. J.
1992-01-01
The design of a multihundred-watt Dynamic Isotope Power System (DIPS), based on the U.S. Department of Energy (DOE) General Purpose Heat Source (GPHS) and small (multihundred-watt) free-piston Stirling engine (FPSE), is being pursued as a potential lower cost alternative to radioisotope thermoelectric generators (RTG's). The design is targeted at the power needs of future unmanned deep space and planetary surface exploration missions ranging from scientific probes to Space Exploration Initiative precursor missions. Power level for these missions is less than a kilowatt. The incentive for any dynamic system is that it can save fuel and reduce costs and radiological hazard. Unlike DIPS based on turbomachinery conversion (e.g. Brayton), this small Stirling DIPS can be advantageously scaled to multihundred-watt unit size while preserving size and mass competitiveness with RTG's. Stirling conversion extends the competitive range for dynamic systems down to a few hundred watts--a power level not previously considered for dynamic systems. The challenge for Stirling conversion will be to demonstrate reliability and life similar to RTG experience. Since the competitive potential of FPSE as an isotope converter was first identified, work has focused on feasibility of directly integrating GPHS with the Stirling heater head. Thermal modeling of various radiatively coupled heat source/heater head geometries has been performed using data furnished by the developers of FPSE and GPHS. The analysis indicates that, for the 1050 K heater head configurations considered, GPHS fuel clad temperatures remain within acceptable operating limits. Based on these results, preliminary characterizations of multihundred-watt units have been established.
ERIC Educational Resources Information Center
Bermingham, Nicola; Higham, Gwennan
2017-01-01
This seminar was held at Heriot-Watt University, Edinburgh, on 27 May 2016. It was jointly organised by BAAL members Nicola Bermingham (Heriot-Watt University) and Gwennan Higham (Swansea University) in collaboration with COST Action IS1306 New Speakers in a Multilingual Europe: Opportunities and Challenges, and supported by the Intercultural…
2012-08-16
threshold of 18% strain, 161 edges were removed. Watts and Strogatz [66] define the small-world network based on the clustering coefficient of the network and...NeuroImage 52: 1059–1069. 65. Latora V, Marchiori M (2001) Efficient behavior of small-world networks. Phys Rev Lett 87: 198701. 66. Watts DJ, Strogatz SH
2012-08-16
death threshold. Using an injury threshold of 18% strain, 161 edges were removed. Watts and Strogatz [66] define the small-world network based on the...NeuroImage 52: 1059–1069. 65. Latora V, Marchiori M (2001) Efficient behavior of small-world networks. Phys Rev Lett 87: 198701. 66. Watts DJ, Strogatz SH
47 CFR 73.213 - Grandfathered short-spaced stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... application for authority to operate a Class A station with no more than 3000 watts ERP and 100 meters antenna HAAT (or equivalent lower ERP and higher antenna HAAT based on a class contour distance of 24 km) must... application for authority to operate a Class A station with more than 3000 watts ERP (up to a maximum of 5800...
47 CFR 73.213 - Grandfathered short-spaced stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... application for authority to operate a Class A station with no more than 3000 watts ERP and 100 meters antenna HAAT (or equivalent lower ERP and higher antenna HAAT based on a class contour distance of 24 km) must... application for authority to operate a Class A station with more than 3000 watts ERP (up to a maximum of 5800...
47 CFR 22.567 - Technical channel assignment criteria.
Code of Federal Regulations, 2011 CFR
2011-10-01
... meters p is the radial ERP in Watts (1) Whenever the actual HAAT is less than 30 meters (98 feet), 30... must not be less than 27 dB less than the maximum ERP in any direction, or 0.1 Watt, whichever is more... contour using the formula in paragraph (c) of this section with actual HAAT and ERP data for the inter...
2008-05-01
pyranometer (Kipp/Zonen-CM3). A Campbell CR23X micro-logger recorded the standard meteorological parameters in 1-min averages. 3 Figure 2... Pyranometer Kipp/Zonen CM3 Watts/meter2 Net solar radiation Net radiometer Kipp/Zonen NR-LITE Watts/meter2 Table 4. W07US tower configuration. Tower Number
Isothermal enthalpy relaxation of glassy 1,2,6-hexanetriol
NASA Astrophysics Data System (ADS)
Fransson, Å.; Bäckström, G.
The isothermal enthalpy relaxation of glassy 1,2,6-hexanetriol has been measured at six temperatures. The relaxation time and the distribution parameters extracted from fits of the Williams-Watts relaxation function are compared with parameters obtained by other techniques and on other substances. A detailed comparison of the Williams-Watts and the Davidson-Cole relaxation functions is presented.
Hey you! Shut the refrigerator door!
NASA Astrophysics Data System (ADS)
Fay, Sarah; Portenga, Angela
1998-09-01
The note discusses electrical power and energy and includes possible labs to be used in a physics classroom. It is based on our experimentation with a new device called the Watt-Watt/Hour Meter, which displays instantaneous power and cumulative energy readings of household electrical devices. Our experiments utilized this meter in conjunction with various appliances and focused primarily on its use with a refrigerator.
Verification testing of the Watts Premier M-Series M-15,000 RO Treatment System was conducted over a 31-day period from April 26, 2004, through May 26, 2004. This test was conducted at the Coachella Valley Water District (CVWD) Well 7802 in Thermal, California. The source water...
Wave Energy Prize - 1/50th Testing - Super Watt Wave Catcher Barge Team
Wesley Scharmen
2015-12-04
This submission of data includes all the 1/50th scale testing data completed on the Wave Energy Prize for the Super Watt Wave Catcher Barge team, and includes: 1/50th test data (raw & processed) 1/50th test data video and pictures 1/50th Test plans and testing documents SSTF_Submission (summarized results)
47 CFR 22.567 - Technical channel assignment criteria.
Code of Federal Regulations, 2010 CFR
2010-10-01
... must be used as the value for h in the above formula. (2) The value used for p in the above formula... radial distance in kilometers h is the radial antenna HAAT in meters p is the radial ERP in Watts... distance in kilometers h is the radial antenna HAAT in meters p is the radial ERP in Watts (3) The value...
47 CFR 17.53 - Lighting equipment and paint.
Code of Federal Regulations, 2011 CFR
2011-10-01
... AC No. 150/5345-43B 4). 116-Watt lamp No. 116 A21/TS (6,000 h). 125-Watt lamp No. 125 A21/TS (6,000 h... Administration, 800 Independence Avenue SW., Washington, D.C. 20591. 4 Copies of Federal Aviation Administration... specifications, bulletins, and drawings (lamps are referred to by standard numbers): Outside white TT-P-102 1...
Highly Efficient Small Form Factor LED Retrofit Lamp
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steven Allen; Fred Palmer; Ming Li
2011-09-11
This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent powermore » quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.« less
Code of Federal Regulations, 2014 CFR
2014-04-01
... work? (a) Benefits are available only while the effects of a work-related condition continue... work is available within the employee's demonstrated commuting area and the employee's qualifications...
Code of Federal Regulations, 2013 CFR
2013-04-01
... work? (a) Benefits are available only while the effects of a work-related condition continue... work is available within the employee's demonstrated commuting area and the employee's qualifications...
Code of Federal Regulations, 2012 CFR
2012-04-01
... work? (a) Benefits are available only while the effects of a work-related condition continue... work is available within the employee's demonstrated commuting area and the employee's qualifications...
Code of Federal Regulations, 2011 CFR
2011-04-01
... work? (a) Benefits are available only while the effects of a work-related condition continue... current physical limitations, whether the work is available within the employee's demonstrated commuting...
Code of Federal Regulations, 2010 CFR
2010-04-01
... work? (a) Benefits are available only while the effects of a work-related condition continue... current physical limitations, whether the work is available within the employee's demonstrated commuting...
Silva, Luciete Almeida; Lima, Kátia Maria da Silva; Fernandes, Ormezinda Celeste Cristo; Balassiano, Ilana Teruszkin; Avelar, Kátia Eliane Santos; Jesus, Michele Silva de
2016-01-01
Leptospirosis is caused by a bacterium of the genus Leptospira. This study aimed at investigating the seroprevalence of and risk factors for leptospirosis in humans in Manaus, State of Amazonas. Interviews were performed, and 1,000 blood serum samples were examined using a microscopic agglutination test. Forty-three cases were positive; there were 10 serotypes, with coagglutination in 8 cases. The most frequently occurring serotypes were Icterohaemorrhagiae (20.7%), Cynopteri (20.7%), Australis (18.8%), and Copenhageni (16.9%), and the Midwest (54.7%) and South (23.8%) had the most cases; these areas lack basic sanitation. Disease occurrence might be reduced through improved basic infrastructural conditions.
From Planck Constant to Isomorphicity Through Justice Paradox
NASA Astrophysics Data System (ADS)
Hidajatullah-Maksoed, Widastra
2015-05-01
Robert E. Scott in his ``Chaos theory and the Justice Paradox'', William & Mary Law Review, v 35, I 1, 329 (1993) wrotes''...As we approach the 21-st Century, the signs of social disarray are everywhere. Social critics observe the breakdown of core structure - the nuclear family, schools, neighborhoods & political groups''. For completions for ``soliton'' first coined by Morikazu TODA, comparing the ``Soliton on Scott-Russell aqueduct on the Union Canal near Heriot-WATT University, July 12, 1995 to Michael Stock works: ``a Fine WATT-Balance: Determination of Planck constant & Redefinition of Kilogram'', January 2011, we can concludes the inherencies between `chaos' & `soliton'. Further through ``string theory'' from Michio KAKU sought statements from Peter Mayr: Stringy world brane & Exponential hierarchy'', JHEP 11 (2000): ``if the 5-brane is embedded in flat 10-D space time, the 6-D Planck mass on the brane is infinite'' who also describes the relation of isomorphicity & ``string theory'', from whom denotes the smart city. Replace this text with your abstract body. Incredible acknowledgments to HE. Mr. Drs. P. SWANTORO & HE. Mr. Dr-HC Jakob OETAMA.
NASA photovoltaic research and technology
NASA Technical Reports Server (NTRS)
Flood, Dennis J.
1988-01-01
NASA photovoltaic R and D efforts address future Agency space mission needs through a comprehensive, integrated program. Activities range from fundamental studies of materials and devices to technology demonstrations of prototype hardware. The program aims to develop and apply an improved understanding of photovoltaic energy conversion devices and systems that will increase the performance, reduce the mass, and extend the lifetime of photovoltaic arrays for use in space. To that end, there are efforts aimed at improving cell efficiency, reducing the effects of space particulate radiation damage (primarily electrons and protons), developing ultralightweight cells, and developing advanced ray component technology for high efficiency concentrator arrays and high performance, ultralightweight arrays. Current goals that have been quantified for the program are to develop cell and array technology capable of achieving 300 watts/kg for future missions for which mass is a critical factor, or 300 watts/sq m for future missions for which array size is a major driver (i.e., Space Station). A third important goal is to develop cell and array technology which will survive the GEO space radiation environment for at least 10 years.
Space LOX vent system. [for space shuttle orbiter
NASA Technical Reports Server (NTRS)
Erickson, R. C.
1975-01-01
This is the final report summarizing the work completed under contract NAS8-26972. Concept selection, design, fabricating and testing of a prototype compact heat exchanger thermodynamic vent system are discussed. The system is designed to operate in a 2.7m (9 foot) spherical liquid oxygen tank with a heating rate of 32.2 - 35.2 watts (110-120 Btu/hr) and to control pressure to 310 + or - 13.8 kN/sq m (45 + or - 2.0 psia.) the design mission is of 2,590 ks (30 days) duration on board a space shuttle orbiter.
1988-07-01
iv BROADBAND ANTENNAS Contents 21. "Performance Characteristics of Notch Array Elements Over a 6/1 263 Frequoncy Band," C. J. Monser * 22. " Broadband ...synthesized RF signal is taken from the output port of the Hewlett-Packard 8408B Microvae Network Alnalyzer to a 20-watt TWT anplifier, and then to...j kr -Sinn H 0 = -jk 47rjk ° a 2 H r4 0 r 406 4. Helix antenna The cur-ent distribution of a helix antenna as shown in Fig. 2.11 of [33 may be
1.34 µm picosecond self-mode-locked Nd:GdVO4 watt-level laser
NASA Astrophysics Data System (ADS)
Han, Ming; Peng, Jiying; Li, Zuohan; Cao, Qiuyuan; Yuan, Ruixia
2017-01-01
With a simple linear configuration, a diode-pumped, self-mode-locked Nd:GdVO4 laser at 1.34 µm is experimentally demonstrated for the first time. Based on the aberrationless theory of self-focusing and thermal lensing effect, through designing and optimizing the resonator, a pulse width as short as 9.1 ps is generated at a repetition rate of 2.0 GHz and the average output power is 2.51 W. The optical conversion efficiency and the slope efficiency for the stable mode-locked operation are approximately 16.7% and 19.2%, respectively.
Stressed and unstressed Ge:Ga detector arrays for airborne astronomy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stacey, G.J.; Beeman, J.W.; Haller, E.E.
1992-11-01
We have constructed and used two dimensional arrays of both unstressed and stressed Ge:GA photoconductive detectors for far-infrared astronomy from the Kuiper Airborne Observatory (KAO). The 25 element (5 x 5) arrays are designed for a new cryogenically cooled spectrometer, the MPE/UCB Far-Infrared Imaging Fabry-Perot Interferometer (FIFI). All of the pixels for the stressed array performed well on the first flights with FIFI; 25% of the detectors in the array are more sensitive than our best single element detector, with background limited noise equivalent powers (NEPs) [approx lt] 3.0 [times] 10[sup [minus]15] W Hz[sup [minus]1/2] at 158 [mu]m and 40more » km s[sup [minus]1] spectral resolution. The average array element performs within [plus minus] 15% of this value. With a bias field of 0.1 V/cm, the average detector response is 20 [plus minus] 6 Amp/Watt at 158 [mu]m. The cutoff wavelength and response also compare well with our single element detectors. The unstressed array delivers significantly better performance than our single element detector due to the lower thermal background in the new spectrometer. The average background limited NEP at 88 [mu]m and 35 km s[sup [minus]1] spectral resolution is approx. 7 [times] 10[sup [minus]15] W Hz[sup [minus]1/2]. 18 refs., 10 figs., 2 tabs.« less
Evaluation of electrosurgical interference to low-power spread-spectrum local area net transceivers.
Gibby, G L; Schwab, W K; Miller, W C
1997-11-01
To study whether an electrosurgery device interferes with the operation of a low-power spread-spectrum wireless network adapter. Nonrandomized, unblinded trials with controls, conducted in the corridor of our institution's operating suite using two portable computers equipped with RoamAbout omnidirectional 250 mW spread-spectrum 928 MHz wireless network adapters. To simulate high power electrosurgery interference, a 100-watt continuous electrocoagulation arc was maintained five feet from the receiving adapter, while device reported signal to noise values were measured at 150 feet and 400 feet distance between the wireless-networked computers. At 150 feet range, and with continuous 100-watt electrocoagulation arc five feet from one computer, error-corrected local area net throughput was measured by sending and receiving a large file multiple times. The reported signal to noise (N = 50) decreased with electrocoagulation from 36.42+/-3.47 (control) to 31.85+/-3.64 (electrocoagulation) (p < 0.001) at 400 feet inter-adapter distance, and from 64.53+/-1.43 (control) to 60.12+/-3.77 (electrocoagulation) (p < 0.001) at 150 feet inter-adapter distance. There was no statistically significant change in network throughput (average 93 kbyte/second) at 150 feet inter-adapter distance, either transmitting or receiving during continuous 100 Watt electrocoagulation arc. The manufacturer indicates "acceptable" performance will be obtained with signal to noise values as low as 20. In view of this, while electrocoagulation affects this spread spectrum network adapter, the effects are small even at 400 feet. At a distance of 150 feet, no discernible effect on network communications was found, suggesting that if other obstructions are minimal, within a wide range on one floor of an operating suite, network communications may be maintained using the technology of this wireless spread spectrum network adapter. The impact of such adapters on cardiac pacemakers should be studied. Wireless spread spectrum network adapters are an attractive technology for mobile computer communications in the operating room.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prabakar, Kumaraguru; Shirazi, Mariko; Singh, Akanksha
Penetration levels of solar photovoltaic (PV) generation on the electric grid have increased in recent years. In the past, most PV installations have not included grid-support functionalities. But today, standards such as the upcoming revisions to IEEE 1547 recommend grid support and anti-islanding functions-including volt-var, frequency-watt, volt-watt, frequency/voltage ride-through, and other inverter functions. These functions allow for the standardized interconnection of distributed energy resources into the grid. This paper develops and tests low-level inverter current control and high-level grid support functions. The controller was developed to integrate advanced inverter functions in a systematic approach, thus avoiding conflict among the differentmore » control objectives. The algorithms were then programmed on an off-the-shelf, embedded controller with a dual-core computer processing unit and field-programmable gate array (FPGA). This programmed controller was tested using a controller-hardware-in-the-loop (CHIL) test bed setup using an FPGA-based real-time simulator. The CHIL was run at a time step of 500 ns to accommodate the 20-kHz switching frequency of the developed controller. The details of the advanced control function and CHIL test bed provided here will aide future researchers when designing, implementing, and testing advanced functions of PV inverters.« less
NASA Astrophysics Data System (ADS)
Naveen, A.; Krishnamurthy, L.; Shridhar, T. N.
2018-04-01
Tungsten (W) and Alumina (Al2O3) thin films have been developed using co-sputtering technique on SS304, Copper (Cu) and Glass slides using Direct Current magnetron sputtering (DC) and Radio Frequency (RF) magnetron sputtering methods respectively. Central Composite Design (CCD) method approach has been adopted to determine the number of experimental plans for deposition and DC power, RF power and Argon gas flow rate have been input parameters, each at 5 levels for development of thin films. In this research paper, study has been carried out determine the optimized condition of deposition parameters for thickness and surface roughness of the thin films. Thickness and average Surface roughness in terms of nanometer (nm) have been characterized by thickness profilometer and atomic force microscopy respectively. The maximum and minimum average thickness observed to be 445 nm and 130 respectively. The optimum deposition condition for W/Al2O3 thin film growth was determined to be at 1000 watts of DC power and 800 watts of RF power, 20 minutes of deposition time, and almost 300 Standard Cubic Centimeter(SCCM) of Argon gas flow. It was observed that average roughness difference found to be less than one nanometer on SS substrate and one nanometer on copper approximately.
Evaluating office lighting environments: Second-level analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collins, B.L.; Fisher, W.S.; Gillette, G.L.
1989-04-01
Data from a post-occupancy evaluation (POE) of 912 work stations with lighting power density (LPD), photometric, and occupant-response measures were examined in a detailed, second-level analysis. Seven types of lighting systems were identified with different combinations of direct and indirect ambient lighting, and task lighting and daylight. The mean illuminances at the primary task location were within the IES target values for office task with a range of mean illuminances from 32 to 75 fc, depending on the lighting system. The median LPD was about 2.36 watts/sq ft, with about one-third the work stations having LPD's at or below 2.0more » watts/sq ft. Although a majority of the occupants (69%) were satisfied about their lighting, the highest percentage of those expressing dissatisfaction (37%) with lighting had an indirect fluorescent furniture-mounted (IFFM) system. The negative reaction of so many people to the IFFM system suggests that the combination of task lighting with an indirect ambient system had an important influence on lighting satisfaction, even though task illuminances tended to be higher with the IFFM system. Concepts of lighting quality, visual health, and control were explored, as well as average luminance to explain the negative reactions to the combination of indirect lighting with furniture-mounted lighting.« less
Digital logic optimization using selection operators
NASA Technical Reports Server (NTRS)
Whitaker, Sterling R. (Inventor); Miles, Lowell H. (Inventor); Cameron, Eric G. (Inventor); Gambles, Jody W. (Inventor)
2004-01-01
According to the invention, a digital design method for manipulating a digital circuit netlist is disclosed. In one step, a first netlist is loaded. The first netlist is comprised of first basic cells that are comprised of first kernel cells. The first netlist is manipulated to create a second netlist. The second netlist is comprised of second basic cells that are comprised of second kernel cells. A percentage of the first and second kernel cells are selection circuits. There is less chip area consumed in the second basic cells than in the first basic cells. The second netlist is stored. In various embodiments, the percentage could be 2% or more, 5% or more, 10% or more, 20% or more, 30% or more, or 40% or more.
NASA Astrophysics Data System (ADS)
Hakamada, Masataka; Abe, Tatsuhiko; Mabuchi, Mamoru
2016-09-01
A modified Watts bath coupled with pulsed current electroplating is used to uniformly deposit ultrafine nickel oxide particles (diameter < 4 nm) on multiwalled carbon nanotubes. The capacitance of the multiwalled carbon nanotubes/nickel oxide electrodes was as high as 2480 F g-1 (per mass of nickel oxide), which is close to the theoretical capacitance of NiO.
NREL, Swiss Scientists Power Past Solar Efficiency Records | NREL | News |
of these multijunction silicon-based solar cells, at least in the near term, is the cost. Assuming 30 % efficiency, the researchers estimated the GaInP-based cell would cost $4.85 per watt and the GaAs-based cell would cost $7.15 per watt. But as manufacturing ramps up and the efficiencies of these types of cells
MODELING COMPARATIVE THERMAL PERFORMANCE OF LIGHTWEIGHT FABRICS USING A COMPUTATIONAL DESIGN TOOL
2017-04-14
lost through clothing = ( T / Rc ) + ( pv / Ret ) (5) T = temperature difference between skin and environment (°C) Rc...thermal resistance (m²-°C/Watt) pv = vapor pressure difference between skin and environment (Pa) Ret = water vapor diffusion resistance (m²-Pa/Watt...clothing, and the external environment (wind, temperature, humidity, solar radiation). Activity: Stationary Anatomic Build: Newton, Fine
ERIC Educational Resources Information Center
Barber, Angela B.; Wetherby, Amy M.; Chambers, Nola W.
2012-01-01
The present study extended the findings of Watt et al. (J Autism Dev Disord 38:1518-1533, 2008) by investigating repetitive and stereotyped behaviors (RSB) demonstrated by children (n = 50) and typical development (TD; n = 50) matched on developmental age, gender, and parents' education level. RSB were coded from videotaped Communication and…