Dose limits to the lens of the eye: International Basic Safety Standards and related guidance.
Boal, T J; Pinak, M
2015-06-01
The International Atomic Energy Agency (IAEA) safety requirements: 'General Safety Requirements Part 3--Radiation protection and safety of radiation sources: International Basic Safety Standards' (BSS) was approved by the IAEA Board of Governors at its meeting in September 2011, and was issued as General Safety Requirements Part 3 in July 2014. The equivalent dose limit for the lens of the eye for occupational exposure in planned exposure situations was reduced from 150 mSv year(-1) to 20 mSv year(-1), averaged over defined periods of 5 years, with no annual dose in a single year exceeding 50 mSv. This reduction in the dose limit for the lens of the eye followed the recommendation of the International Commission on Radiological Protection in its statement on tissue reactions of 21 April 2011. IAEA has developed guidance on the implications of the new dose limit for the lens of the eye. This paper summarises the process that led to the inclusion of the new dose limit for the lens of the eye in the BSS, and the implications of the new dose limit. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Effects of an oral iron chelator, deferasirox, on advanced hepatocellular carcinoma.
Saeki, Issei; Yamamoto, Naoki; Yamasaki, Takahiro; Takami, Taro; Maeda, Masaki; Fujisawa, Koichi; Iwamoto, Takuya; Matsumoto, Toshihiko; Hidaka, Isao; Ishikawa, Tsuyoshi; Uchida, Koichi; Tani, Kenji; Sakaida, Isao
2016-10-28
To evaluate the inhibitory effects of deferasirox (DFX) against hepatocellular carcinoma (HCC) through basic and clinical studies. In the basic study, the effect of DFX was investigated in three hepatoma cell lines (HepG2, Hep3B, and Huh7), as well as in an N-nitrosodiethylamine-induced murine HCC model. In the clinical study, six advanced HCC patients refractory to chemotherapy were enrolled. The initial dose of DFX was 10 mg/kg per day and was increased by 10 mg/kg per day every week, until the maximum dose of 30 mg/kg per day. The duration of a single course of DFX therapy was 28 consecutive days. In the event of dose-limiting toxicity (according to the Common Terminology Criteria for Adverse Events v.4.0), DFX dose was reduced. Administration of DFX inhibited the proliferation of hepatoma cell lines and induced the activation of caspase-3 in a dose-dependent manner in vitro . In the murine model, DFX treatment significantly suppressed the development of liver tumors ( P < 0.01), and significantly upregulated the mRNA expression levels of hepcidin ( P < 0.05), transferrin receptor 1 ( P < 0.05), and hypoxia inducible factor-1α ( P < 0.05) in both tumor and non-tumor tissues, compared with control mice. In the clinical study, anorexia and elevated serum creatinine were observed in four and all six patients, respectively. However, reduction in DFX dose led to decrease in serum creatinine levels in all patients. After the first course of DFX, one patient discontinued the therapy. We assessed the tumor response in the remaining five patients; one patient exhibited stable disease, while four patients exhibited progressive disease. The one-year survival rate of the six patients was 17%. We demonstrated that DFX inhibited HCC in the basic study, but not in the clinical study due to dose-limiting toxicities.
Broughton, J; Cantone, M C; Ginjaume, M; Shah, B; Czarwinski, R
2015-06-01
In April 2011, the International Commission on Radiological Protection issued a statement on reduction of the equivalent dose limits for the lens of the eye, and strongly recommended its consideration in the revision of the International Atomic Energy Agency's International Basic Safety Standards on Radiation Protection. The reduced dose limit was incorporated in the final version of the Basic Safety Standards. As significant concern was expressed by radiation protection professionals worldwide, the International Radiation Protection Association (IRPA) established a task group to assess the impact of implementation of the revised dose limit for the lens of the eye for occupational exposure. IRPA Associate Societies (ASs) were asked for their views using a questionnaire addressing three topics: implications for dosimetry, implications for methods of protection, and wider implications. The responses received indicate various methods of approach and express different points of view, reflecting nuances of particular ASs or specific professional groups. Topic experts nominated by ASs were selected to assist with collation of responses, and a report was produced by the task group. Conclusions were drawn on the three issues, including potential cost implications. A number of recommendations were drawn from the responses received including: the request for more understanding about the relationship between exposure of the lens of the eye and cataract formation, and further guidance to assist implementation; the importance of economic and social considerations when introducing the limits into national regulations; the need to propose or define procedures related to employment of people with existing or pre-cataract conditions; and the practical aspects relating to dosimetry and protective equipment. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Sadasivam, Rajani S; Gathibandhe, Vaibhav; Tanik, Murat M; Willig, James H
2012-06-01
Medication dosing errors can greatly reduce HIV treatment effectiveness as incorrect dosing leads to drug resistance and non-adherence. In order to dose correctly, HIV therapy providers must balance several patient characteristics such as renal functions and weight. In developing countries and other resource-limited settings, dosing errors are more likely because treatment is provided by mid-level providers with only basic training in HIV therapy. These providers also typically lack electronic tools informing medical decisions. Widespread adoption of mobile phones in developing nations offers an opportunity to implement a point-of-care system to help providers reduce dosing errors. We discuss the development of the mHIV-Dr system prototype using the new Android mobile platform. mHIV-Dr is being designed to provide dosing recommendations for front-line providers in developing countries. We also discuss the additional challenges in the implementation of the mHIV-Dr system in a resource limited setting.
Omar, Artur; Kadesjö, Nils; Palmgren, Charlotta; Marteinsdottir, Maria; Segerdahl, Tony; Fransson, Annette
2017-03-20
In accordance with recommendations by the International Commission on Radiological Protection, the current European Basic Safety Standards has adopted a reduced occupational eye lens dose limit of 20 mSv yr -1 . The radiation safety implications of this dose limit is of concern for clinical staff that work with relatively high dose x-ray angiography and interventional radiology. Presented in this work is a thorough assessment of the occupational eye lens dose based on clinical measurements with active personal dosimeters worn by staff during various types of procedures in interventional radiology, cardiology and neuroradiology. Results are presented in terms of the estimated equivalent eye lens dose for various medical professions. In order to compare the risk of exceeding the regulatory annual eye lens dose limit for the widely different clinical situations investigated in this work, the different medical professions were separated into categories based on their distinct work pattern: staff that work (a) regularly beside the patient, (b) in proximity to the patient and (c) typically at a distance from the patient. The results demonstrate that the risk of exceeding the annual eye lens dose limit is of concern for staff category (a), i.e. mainly the primary radiologist/cardiologist. However, the results also demonstrate that the risk can be greatly mitigated if radiation protection shields are used in the clinical routine. The results presented in this work cover a wide range of clinical situations, and can be used as a first indication of the risk of exceeding the annual eye lens dose limit for staff at other medical centres.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santucci, P.; Guetat, P.
1993-12-31
This document describes the code CERISE, Code d`Evaluations Radiologiques Individuelles pour des Situations en Enterprise et dans l`Environnement. This code has been developed in the frame of European studies to establish acceptance criteria of very low-level radioactive waste and materials. This code is written in Fortran and runs on PC. It calculates doses received by the different pathways: external exposure, ingestion, inhalation and skin contamination. Twenty basic scenarios are already elaborated, which have been determined from previous studies. Calculations establish the relation between surface, specific and/or total activities, and doses. Results can be expressed as doses for an average activitymore » unit, or as average activity limits for a set of reference doses (defined for each scenario analyzed). In this last case, the minimal activity values and the corresponding limiting scenarios, are selected and summarized in a final table.« less
Zhao, Yang; Hebert, Mary F.; Venkataramanan, Raman
2017-01-01
Pregnancy is associated with a variety of physiological changes that can alter the pharmacokinetics and pharmacodynamics of several drugs. However, limited data exists on the pharmacokinetics and pharmacodynamics of the majority of the medications used in pregnancy. In this article, we first describe basic concepts (drug absorption, bioavailability, distribution, metabolism, elimination, and transport) in pharmacokinetics. Then, we discuss several physiological changes that occur during pregnancy that theoretically affect absorption, distribution, metabolism, and elimination. Further, we provide a brief review of the literature on the clinical pharmacokinetic studies performed in pregnant women in recent years. In general, pregnancy increases the clearance of several drugs and correspondingly decreases drug exposure during pregnancy. Based on current drug exposure measurements during pregnancy, alterations in the dose or dosing regimen of certain drugs are essential during pregnancy. More pharmacological studies in pregnant women are needed to optimize drug therapy in pregnancy. PMID:25281357
Determination of quality parameters from statistical analysis of routine TLD dosimetry data.
German, U; Weinstein, M; Pelled, O
2006-01-01
Following the as low as reasonably achievable (ALARA) practice, there is a need to measure very low doses, of the same order of magnitude as the natural background, and the limits of detection of the dosimetry systems. The different contributions of the background signals to the total zero dose reading of thermoluminescence dosemeter (TLD) cards were analysed by using the common basic definitions of statistical indicators: the critical level (L(C)), the detection limit (L(D)) and the determination limit (L(Q)). These key statistical parameters for the system operated at NRC-Negev were quantified, based on the history of readings of the calibration cards in use. The electronic noise seems to play a minor role, but the reading of the Teflon coating (without the presence of a TLD crystal) gave a significant contribution.
Kuempel, Eileen D.; Sweeney, Lisa M.; Morris, John B.; Jarabek, Annie M.
2015-01-01
The purpose of this article is to provide an overview and practical guide to occupational health professionals concerning the derivation and use of dose estimates in risk assessment for development of occupational exposure limits (OELs) for inhaled substances. Dosimetry is the study and practice of measuring or estimating the internal dose of a substance in individuals or a population. Dosimetry thus provides an essential link to understanding the relationship between an external exposure and a biological response. Use of dosimetry principles and tools can improve the accuracy of risk assessment, and reduce the uncertainty, by providing reliable estimates of the internal dose at the target tissue. This is accomplished through specific measurement data or predictive models, when available, or the use of basic dosimetry principles for broad classes of materials. Accurate dose estimation is essential not only for dose-response assessment, but also for interspecies extrapolation and for risk characterization at given exposures. Inhalation dosimetry is the focus of this paper since it is a major route of exposure in the workplace. Practical examples of dose estimation and OEL derivation are provided for inhaled gases and particulates. PMID:26551218
Arrossi, Silvina; Temin, Sarah; Garland, Suzanne; Eckert, Linda O'Neal; Bhatla, Neerja; Castellsagué, Xavier; Alkaff, Sharifa Ezat; Felder, Tamika; Hammouda, Doudja; Konno, Ryo; Lopes, Gilberto; Mugisha, Emmanuel; Murillo, Rául; Scarinci, Isabel C; Stanley, Margaret; Tsu, Vivien; Wheeler, Cosette M; Adewole, Isaac Folorunso; de Sanjosé, Silvia
2017-10-01
To provide resource-stratified (four tiers), evidence-based recommendations on the primary prevention of cervical cancer globally. The American Society of Clinical Oncology convened a multidisciplinary, multinational panel of oncology, obstetrics/gynecology, public health, cancer control, epidemiology/biostatistics, health economics, behavioral/implementation science, and patient advocacy experts. The Expert Panel reviewed existing guidelines and conducted a modified ADAPTE process and a formal consensus-based process with additional experts (consensus ratings group) for one round of formal ratings. Existing sets of guidelines from five guideline developers were identified and reviewed; adapted recommendations formed the evidence base. Five systematic reviews, along with cost-effectiveness analyses, provided evidence to inform the formal consensus process, which resulted in agreement of ≥ 75%. In all resource settings, two doses of human papillomavirus vaccine are recommended for girls age 9 to 14 years, with an interval of at least 6 months and possibly up to 12 to 15 months. Individuals with HIV positivity should receive three doses. Maximal and enhanced settings: if girls are age ≥ 15 years and received their first dose before age 15 years, they may complete the series; if no doses were received before age 15 years, three doses should be administered; in both scenarios, vaccination may be through age 26 years. Limited and basic settings: if sufficient resources remain after vaccinating girls age 9 to 14 years, girls who received one dose may receive additional doses between age 15 and 26 years. Maximal, enhanced, and limited settings: if ≥ 50% coverage in the priority female target population, sufficient resources, and cost effectiveness, boys may be vaccinated to prevent other noncervical human papillomavirus-related cancers and diseases. Basic settings: vaccinating boys is not recommended. It is the view of the American Society of Clinical Oncology that health care providers and health care system decision makers should be guided by the recommendations for the highest stratum of resources available. The guideline is intended to complement but not replace local guidelines.
NASA Astrophysics Data System (ADS)
Schreiner, L. J.
2017-05-01
For seventeen years a community of basic and clinical scientists and researchers has been meeting bi-annually to promote the clinical advance of techniques to measure radiation dose in three dimensions. The interest in this dosimetry was motivated by its promise as an effective methodology for 3D measurement of the complex conformal dose distributions achieved by modern techniques such as Intensity Modulated and Volumetric Arc Radiation Therapy. Each of the International Conferences on 3D Radiation Dosimetry resulted in the publication of informative proceedings [1-8], the majority openly available on the internet. The proceedings included papers that: i) reviewed the basic science of the radiation sensitive materials used to accumulate the dose information, ii) introduced the science and engineering of the imaging systems required to read the information out, iii) described the work flows and systems required for efficient dosimetry, iv) reported the protocols required for reproducible dosimetry, and v) showed examples of clinical use illustrating advantage and limitations of the dosimetry. This paper is intended to use the framework provided by these proceedings to review the current 3D chemical dosimeters available and to discuss the requirements for their use. The paper describes how 3D dosimetry can complement other dose delivery validation approaches available in the clinic. It closes with some personal reflections of how the motivation for, and practice of, 3D dosimetry have changed (or not) over the years.
Dauer, Lawrence T; Ainsbury, Elizabeth A; Dynlacht, Joseph; Hoel, David; Klein, Barbara E K; Mayer, Donald; Prescott, Christina R; Thornton, Raymond H; Vano, Eliseo; Woloschak, Gayle E; Flannery, Cynthia M; Goldstein, Lee E; Hamada, Nobuyuki; Tran, Phung K; Grissom, Michael P; Blakely, Eleanor A
2017-10-01
This review summarizes the conclusions and recommendations of the new National Council on Radiation Protection and Measurements (NCRP) Commentary No. 26 guidance on radiation dose limits for the lens of the eye. The NCRP addressed radiation protection principles in respect to the lens of the eye, discussed the current understanding of eye biology and lens effects, reviewed and evaluated epidemiology, and assessed exposed populations with the potential for significant radiation exposures to the lens while suggesting monitoring and protection practices. Radiation-induced damage to the lens of the eye can include the loss of clarity resulting in opacification or clouding several years after exposure. The impact is highly dependent on the type of radiation, how the exposure of the lens was delivered, the genetic susceptibilities of the individual exposed, and the location of the opacity relative to the visual axis of the individual. The preponderance of epidemiological evidence suggests that lens damage could occur at lower doses than previously considered and the NCRP has determined that it is prudent to reduce the recommended annual lens of the eye occupational dose limit from an equivalent dose of 150 mSv to an absorbed dose of 50 mGy. Significant additional research is still needed in the following areas: comprehensive evaluation of the overall effects of ionizing radiation on the eye, dosimetry methodology and dose-sparing optimization techniques, additional high quality epidemiology studies, and a basic understanding of the mechanisms of cataract development.
Kavet, Robert; Dovan, Thanh; Reilly, J Patrick
2012-12-01
Electric and magnetic field exposure limits published by International Commission for Non-Ionizing Radiation Protection and Institute of Electrical and Electronics Engineers are aimed at protection against adverse electrostimulation, which may occur by direct coupling to excitable tissue and, in the case of electric fields, through indirect means associated with surface charge effects (e.g. hair vibration, skin sensations), spark discharge and contact current. For direct coupling, the basic restriction (BR) specifies the not-to-be-exceeded induced electric field. The key results of anatomically based electric and magnetic field dosimetry studies and the relevant characteristics of excitable tissue were first identified. This permitted us to assess the electric and magnetic field exposure levels that induce dose in tissue equal to the basic restrictions, and the relationships of those exposure levels to the limits now in effect. We identify scenarios in which direct coupling of electric fields to peripheral nerve could be a determining factor for electric field limits.
Operational health physics training
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1992-06-01
The initial four sections treat basic information concerning atomic structure and other useful physical quantities, natural radioactivity, the properties of {alpha}, {beta}, {gamma}, x rays and neutrons, and the concepts and units of radiation dosimetry (including SI units). Section 5 deals with biological effects and the risks associated with radiation exposure. Background radiation and man-made sources are discussed next. The basic recommendations of the ICRP concerning dose limitations: justification, optimization (ALARA concepts and applications) and dose limits are covered in Section seven. Section eight is an expanded version of shielding, and the internal dosimetry discussion has been extensively revised tomore » reflect the concepts contained in the MIRD methodology and ICRP 30. The remaining sections discuss the operational health physics approach to monitoring radiation. Individual sections include radiation detection principles, instrument operation and counting statistics, health physics instruments and personnel monitoring devices. The last five sections deal with the nature of, operation principles of, health physics aspects of, and monitoring approaches to air sampling, reactors, nuclear safety, gloveboxes and hot cells, accelerators and x ray sources. Decontamination, waste disposal and transportation of radionuclides are added topics. Several appendices containing constants, symbols, selected mathematical topics, and the Chart of the Nuclides, and an index have been included.« less
Preliminary Shielding Analysis for HCCB TBM Transport
NASA Astrophysics Data System (ADS)
Miao, Peng; Zhao, Fengchao; Cao, Qixiang; Zhang, Guoshu; Feng, Kaiming
2015-09-01
A preliminary shielding analysis on the transport of the Chinese helium cooled ceramic breeder test blanket module (HCCB TBM) from France back to China after being irradiated in ITER is presented in this contribution. Emphasis was placed on irradiation safety during transport. The dose rate calculated by MCNP/4C for the conceptual package design satisfies the relevant dose limits from IAEA that the dose rate 3 m away from the surface of the package containing low specific activity III materials should be less than 10 mSv/h. The change with location and the time evolution of dose rates after shutdown have also been studied. This will be helpful for devising the detailed transport plan of HCCB TBM back to China in the near future. supported by the Major State Basic Research Development Program of China (973 Program) (No. 2013GB108000)
Arrossi, Silvina; Temin, Sarah; Garland, Suzanne; Eckert, Linda O’Neal; Bhatla, Neerja; Castellsagué, Xavier; Alkaff, Sharifa Ezat; Felder, Tamika; Hammouda, Doudja; Konno, Ryo; Lopes, Gilberto; Mugisha, Emmanuel; Murillo, Rául; Scarinci, Isabel C.; Stanley, Margaret; Tsu, Vivien; Wheeler, Cosette M.; Adewole, Isaac Folorunso; de Sanjosé, Silvia
2017-01-01
Purpose To provide resource-stratified (four tiers), evidence-based recommendations on the primary prevention of cervical cancer globally. Methods The American Society of Clinical Oncology convened a multidisciplinary, multinational panel of oncology, obstetrics/gynecology, public health, cancer control, epidemiology/biostatistics, health economics, behavioral/implementation science, and patient advocacy experts. The Expert Panel reviewed existing guidelines and conducted a modified ADAPTE process and a formal consensus-based process with additional experts (consensus ratings group) for one round of formal ratings. Results Existing sets of guidelines from five guideline developers were identified and reviewed; adapted recommendations formed the evidence base. Five systematic reviews, along with cost-effectiveness analyses, provided evidence to inform the formal consensus process, which resulted in agreement of ≥ 75%. Recommendations In all resource settings, two doses of human papillomavirus vaccine are recommended for girls age 9 to 14 years, with an interval of at least 6 months and possibly up to 12 to 15 months. Individuals with HIV positivity should receive three doses. Maximal and enhanced settings: if girls are age ≥ 15 years and received their first dose before age 15 years, they may complete the series; if no doses were received before age 15 years, three doses should be administered; in both scenarios, vaccination may be through age 26 years. Limited and basic settings: if sufficient resources remain after vaccinating girls age 9 to 14 years, girls who received one dose may receive additional doses between age 15 and 26 years. Maximal, enhanced, and limited settings: if ≥ 50% coverage in the priority female target population, sufficient resources, and cost effectiveness, boys may be vaccinated to prevent other noncervical human papillomavirus–related cancers and diseases. Basic settings: vaccinating boys is not recommended. It is the view of the American Society of Clinical Oncology that health care providers and health care system decision makers should be guided by the recommendations for the highest stratum of resources available. The guideline is intended to complement but not replace local guidelines. PMID:29094100
Toxicity of dietary Heliotropium circinatum to rats.
Eröksüz, H; Eröksüz, Y; Ozer, H; Ceribasi, A O; Tosun, F; Tamer, U; Kizilay, C Akyüz
2003-08-01
Pyrrolizidine alkaloid intoxication was produced in adult, male rats by feeding different levels (0, 1, 3, 5 or 10%) of Heliotropium circinatum for 20 w. Combined GC-MS revealed 0.15% total alkaloid content in the plant material of which 12% and 88% were basic and N-oxide forms, respectively. The specific alkaloids identified were europine (67.33%), heliotrine (16.34%), lasiocarpine (8.12%), heleurine (4.18%), echinatine (1.56%), 7-angeylheliotrine (1.19%), and an unknown alkaloid (1.28%). Neither mortality nor significant clinical changes occurred in test groups. Mild to moderate, dose-related hepatic megalocytosis was the most prominent histopathological finding. In addition to chronic hepatotoxicity, notable medial thickening occurred in the pulmonary arterioles and arteries of the high-dosed groups. This study indicated that H. circinatum plant has limited toxic potential in rats with mild to moderate histological changes and no mortality at the dosing levels, total doses, or time of exposure employed.
NASA Astrophysics Data System (ADS)
Szumska, A.; Budzanowski, M.; Kopeć, R.
2017-11-01
In its statement on tissue reactions approved on 21st April 2011, the International Commission on Radiological Protection (ICRP, 2012) reviewed its recommendation concerning the equivalent dose limit for the eye lens and reduced the dose limits for occupationally exposed persons to 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv. This limit was approved and written down in the new EURATOM (European Atomic Energy Community) directive 2013/59 and in the IAEA (International Atomic Energy Agency) BSS (Basic Safety Standard) of July 2014. For that reason, the necessity to monitor the eye lens may become more important than it was before. However, specially dedicated dosemeters for the dose quantity Hp(3) are using very rarely. Commonly use are only whole body personal dosemeters for the personal dose equivalent quantities Hp(10) worn on the trunk and ring dosemeters worn on finger to measure the quantity Hp(0.07). Therefore, in this work it was investigated whether dosemeters from routine use calibrated in terms of Hp(10) and Hp(0.07) and worn on thyroid collar and protective apron could deliver similar results like dedicated eye lens dosemeter worn close to the eyes. The results show that the best method if dedicated eye lens dosimeters is not used is to measure doses in terms of Hp(0.07) on the thyroid collar (Pearson product, r=0.85). Obtained results shows also importance of proper localization of eye lens dosimeter (close to the eye, from side of the X-ray source).
Brudecki, K; Kowalska, A; Zagrodzki, P; Szczodry, A; Mroz, T; Janowski, P; Mietelski, J W
2017-03-01
This paper presents results of 131 I thyroid activity measurements in 30 members of the nuclear medicine personnel of the Department of Endocrinology and Nuclear Medicine Holy Cross Cancer Centre in Kielce, Poland. A whole-body spectrometer equipped with two semiconductor gamma radiation detectors served as the basic research instrument. In ten out of 30 examined staff members, the determined 131 I activity was found to be above the detection limit (DL = 5 Bq of 131 I in the thyroid). The measured activities ranged from (5 ± 2) Bq to (217 ± 56) Bq. The highest activities in thyroids were detected for technical and cleaning personnel, whereas the lowest values were recorded for medical doctors. Having measured the activities, an attempt has been made to estimate the corresponding annual effective doses, which were found to range from 0.02 to 0.8 mSv. The highest annual equivalent doses have been found for thyroid, ranging from 0.4 to 15.4 mSv, detected for a cleaner and a technician, respectively. The maximum estimated effective dose corresponds to 32% of the annual background dose in Poland, and to circa 4% of the annual limit for the effective dose due to occupational exposure of 20 mSv per year, which is in compliance with the value recommended by the International Commission on Radiological Protection.
[Dose rate-dependent cellular and molecular effects of ionizing radiation].
Przybyszewski, Waldemar M; Wideł, Maria; Szurko, Agnieszka; Maniakowski, Zbigniew
2008-09-11
The aim of radiation therapy is to kill tumor cells while minimizing damage to normal cells. The ultimate effect of radiation can be apoptotic or necrotic cell death as well as cytogenetic damage resulting in genetic instability and/or cell death. The destructive effects of radiation arise from direct and indirect ionization events leading to peroxidation of macromolecules, especially those present in lipid-rich membrane structures as well as chromatin lipids. Lipid peroxidative end-products may damage DNA and proteins. A characteristic feature of radiation-induced peroxidation is an inverse dose-rate effect (IDRE), defined as an increase in the degree of oxidation(at constant absorbed dose) accompanying a lower dose rate. On the other hand, a low dose rate can lead to the accumulation of cells in G2, the radiosensitive phase of the cell cycle since cell cycle control points are not sensitive to low dose rates. Radiation dose rate may potentially be the main factor improving radiotherapy efficacy as well as affecting the intensity of normal tissue and whole-body side effects. A better understanding of dose rate-dependent biological effects may lead to improved therapeutic intervention and limit normal tissue reaction. The study reviews basic biological effects that depend on the dose rate of ionizing radiation.
Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic.
Kroutilķková, Daniela; Novotný, Josef; Judas, Libor
2003-02-01
The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual reader model 4000. Basic mode of the TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. Advanced mode consists of measurements under both reference and non-reference conditions using a solid multipurpose phantom ('Leuven phantom') for photon beams. The radiotherapy centres are instructed to deliver to the TLD on central beam axis absorbed dose of 2 Gy calculated with their treatment planning system for a particular treatment set-up. The TLD measured doses are compared with the calculated ones. Deviations of +/-3% are considered acceptable for both basic and advanced mode of the audit. There are 34 radiotherapy centres in the Czech Republic. They undergo the basic mode of the TLD audit regularly every 2 years. If a centre shows a deviation outside the acceptance level, it is audited more often. Presently, most of the checked beams comply with the acceptance level. The advanced TLD audit has been implemented as a pilot study for the present. The results were mostly within the acceptance limit for the measurements on-axis, whereas for off-axis points they fell beyond the limit more frequently, especially for set-ups with inhomogeneities, oblique incidence and wedges. The results prove the importance of the national TLD quality assurance network. It has contributed to the improvement of clinical dosimetry in the Czech Republic. In addition, it helps the regulatory authority to monitor effectively and regularly radiotherapy centres.
Radiation Parameters of High Dose Rate Iridium -192 Sources
NASA Astrophysics Data System (ADS)
Podgorsak, Matthew B.
A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.
Allowable residual contamination levels of radionuclides in soil from pathway analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nyquist, J.E.; Baes, C.F. III
1987-01-01
The uncertainty regarding radionuclide distributions among Remedial Action Program (RAP) sites and long-term decommissioning and closure options for these sites requires a flexible approach capable of handling different levels of contamination, dose limits, and closure scenarios. We identified a commercially available pathway analysis model, DECOM, which had been used previously in support of remedial activities involving contaminated soil at the Savannah River Plant. The DECOM computer code, which estimates concentrations of radionuclides uniformly distributed in soil that correspond to an annual effective dose equivalent, is written in BASIC and runs on an IBM PC or compatible microcomputer. We obtained themore » latest version of DECOM and modified it to make it more user friendly and applicable to the Oak Ridge National Laboratory (ORNL) RAP. Some modifications involved changes in default parameters or changes in models based on approaches used by the EPA in regulating remedial actions for hazardous substances. We created a version of DECOM as a LOTUS spreadsheet, using the same models as the BASIC version of DECOM. We discuss the specific modeling approaches taken, the regulatory framework that guided our efforts, the strengths and limitations of each approach, and areas for improvement. We also demonstrate how the LOTUS version of DECOM can be applied to specific problems that may be encountered during ORNL RAP activities. 18 refs., 2 figs., 3 tabs.« less
Basic science and clinical management of painful and non-painful chemotherapy-related neuropathy
Kim, Joyce H.; Dougherty, Patrick M.; Abdi, Salahadin
2017-01-01
Chemotherapy-induced peripheral neuropathy (CIPN) is a dose-limiting toxicity of several chemotherapeutics used in the treatment of all the most common malignancies. There are several defined mechanisms of nerve damage that take place along different areas of the peripheral and the central nervous system. Treatment is based on symptom management and there are several classes of medications found to be efficacious in the treatment of neuropathic pain. Neuropathic pain that persists despite appropriate pharmacotherapy may respond to interventional procedures that span a range of invasiveness. The purpose of this review article is to examine the basic science of neuropathy and currently available treatment options in the context of chemotherapy induced peripheral neuropathy. PMID:25584767
Domienik, J; Bissinger, A; Grabowicz, W; Jankowski, Ł; Kręcki, R; Makowski, M; Masiarek, K; Plewka, M; Lubiński, A; Peruga, J Z
2016-06-01
The aim of the study was to check, in clinical practice, the potential for the dose reduction of lead eyewear and a ceiling-suspended shield used to protect the eye lens of physicians working in interventional cardiology. To this end, for the lead eyewear, the dose reduction factors were derived to correct the readings from a dosimeter used routinely outside the glasses. Four types of lead eyewear with attached loose thermoluminescent dosimeters and EYE-D dosimeters were worn by physicians in two clinical centres, for two-month periods, during coronary angiography (CA), percutaneous coronary intervention (PCI), and pacemaker procedures. In order to analyse, separately, how a ceiling-suspended lead screen absorbs the scattered radiation, a series of measurements was carried out during single CA/PCI procedures performed with and without the protection. The lead eyewear may reduce the doses to the eye closest to the x-ray tube by a factor between 1.1 and 3.4, depending on its model and the physician's position. The effectiveness of the eyewear may, however, vary-even for the same model and physician-almost twofold between different working periods. The ceiling-suspended shield decreases the doses in clinical practice by a factor of 2.3. The annual eye lens doses without the eyewear estimated from routine measurements are high-above or close to the new eye lens dose limit established by the recent EU Basic Safety Standards, even though the ceiling-suspended shield was used. Therefore, to comply with the new dose limit that is set in the Directive, protection of the eyes of physicians with high workloads might require the use of both the eyewear and the ceiling-suspended shield.
NASA Astrophysics Data System (ADS)
Ishikawa, Tetsuo; Yasumura, Seiji; Ozasa, Kotaro; Kobashi, Gen; Yasuda, Hiroshi; Miyazaki, Makoto; Akahane, Keiichi; Yonai, Shunsuke; Ohtsuru, Akira; Sakai, Akira; Sakata, Ritsu; Kamiya, Kenji; Abe, Masafumi
2015-08-01
The Fukushima Health Management Survey (including the Basic Survey for external dose estimation and four detailed surveys) was launched after the Fukushima Dai-ichi Nuclear Power Plant accident. The Basic Survey consists of a questionnaire that asks Fukushima Prefecture residents about their behavior in the first four months after the accident; and responses to the questionnaire have been returned from many residents. The individual external doses are estimated by using digitized behavior data and a computer program that included daily gamma ray dose rate maps drawn after the accident. The individual external doses of 421,394 residents for the first four months (excluding radiation workers) had a distribution as follows: 62.0%, <1 mSv 94.0%, <2 mSv 99.4%, <3 mSv. The arithmetic mean and maximum for the individual external doses were 0.8 and 25 mSv, respectively. While most dose estimation studies were based on typical scenarios of evacuation and time spent inside/outside, the Basic Survey estimated doses considering individually different personal behaviors. Thus, doses for some individuals who did not follow typical scenarios could be revealed. Even considering such extreme cases, the estimated external doses were generally low and no discernible increased incidence of radiation-related health effects is expected.
Ishikawa, Tetsuo; Yasumura, Seiji; Ozasa, Kotaro; Kobashi, Gen; Yasuda, Hiroshi; Miyazaki, Makoto; Akahane, Keiichi; Yonai, Shunsuke; Ohtsuru, Akira; Sakai, Akira; Sakata, Ritsu; Kamiya, Kenji; Abe, Masafumi
2015-01-01
The Fukushima Health Management Survey (including the Basic Survey for external dose estimation and four detailed surveys) was launched after the Fukushima Dai-ichi Nuclear Power Plant accident. The Basic Survey consists of a questionnaire that asks Fukushima Prefecture residents about their behavior in the first four months after the accident; and responses to the questionnaire have been returned from many residents. The individual external doses are estimated by using digitized behavior data and a computer program that included daily gamma ray dose rate maps drawn after the accident. The individual external doses of 421,394 residents for the first four months (excluding radiation workers) had a distribution as follows: 62.0%, <1 mSv; 94.0%, <2 mSv; 99.4%, <3 mSv. The arithmetic mean and maximum for the individual external doses were 0.8 and 25 mSv, respectively. While most dose estimation studies were based on typical scenarios of evacuation and time spent inside/outside, the Basic Survey estimated doses considering individually different personal behaviors. Thus, doses for some individuals who did not follow typical scenarios could be revealed. Even considering such extreme cases, the estimated external doses were generally low and no discernible increased incidence of radiation-related health effects is expected. PMID:26239643
Gbadago, J K; Faanhof, A; Darko, E O; Schandorf, C
2011-09-01
The possible environmental impacts of naturally occurring radionuclides on workers and a critical community, as a result of milling and processing sulfide ores for gold by a mining company at Bogoso in the western region of Ghana, have been investigated using gamma spectroscopy. Indicative doses for the workers during sulfide ore processing were calculated from the activity concentrations measured at both physical and chemical processing stages. The dose rate, annual effective dose equivalent, radium equivalent activity, external and internal hazard indices, and radioactivity level index for tailings, for the de-silted sediments of run-off from the vicinity of the tailings dam through the critical community, and for the soils of the critical community's basic schools were calculated and found to be lower than their respective permissible limits. The environmental impact of the radionuclides is therefore expected to be low in this mining environment.
Dominicus, Rolf; Galtier, Florence; Richard, Patrick; Baudin, Martine
2014-06-30
The immunogenicity and safety of one dose of Tdap-IPV (tetanus, diphtheria, acellular pertussis and inactivated poliomyelitis vaccine) and two doses of Td-IPV (tetanus, diphtheria and inactivated poliomyelitis vaccine) were assessed in adults who had not received a diphtheria- and tetanus-containing vaccine in the last 20 years. This open-label, multicentre study was conducted in adults aged ≥ 40 years with no diphtheria- and tetanus-containing vaccine in the last 20 years. Participants received one dose of Tdap-IPV followed by two doses of Td-IPV (0, 1, 6 month schedule). Primary immunogenicity objectives: to demonstrate acceptable seroprotection rates (percentage of participants with antibody titre above threshold) post-dose 3 for diphtheria (≥ 0.1IU/mL by seroneutralization assay [SNA]); tetanus (≥ 0.1IU/mL by enzyme-linked immunosorbent assay [ELISA]); and poliomyelitis (≥ 8 1/dil by SNA); and to evaluate the percentage of participants with an antibody concentration ≥ 5EU/mL (by ELISA) for pertussis antigens post-dose 1. Seroprotection rates were acceptable if the lower limit of the 95% confidence interval (CI) was >95%. Percentage of participants with basic clinical immunity against diphtheria (≥ 0.01IU/mL) was also assessed. Safety (adverse events [AEs] and serious AEs) was assessed after each dose. Overall, 336 participants were included (mean age: 60.2 years). Post-dose 3 seroprotection rates were: diphtheria, 94.6% (CI 91.5-96.8); tetanus and poliomyelitis, 100% (CI: 98.8-100). Percentage of participants with an antibody titre ≥ 5EU/mL against pertussis antigens was ≥ 95.8% for all five pertussis components. Basic clinical immunity against diphtheria was achieved in 100% (CI: 98.8-100) of participants. AEs were reported more frequently following vaccination with Tdap-IPV (post-dose 1: 65.3%) than with Td-IPV (post-dose 2: 48.3%; post-dose 3: 50.3%). This study highlights the benefits of using Tdap-IPV followed by two doses of Td-IPV in an adult population to achieve maximal protection against diphtheria, tetanus, poliomyelitis and pertussis simultaneously. Copyright © 2014 Elsevier Ltd. All rights reserved.
Physics of vascular brachytherapy.
Jani, S K
1999-08-01
Basic physics plays an important role in understanding the clinical utility of radioisotopes in brachytherapy. Vascular brachytherapy is a very unique application of localized radiation in that dose levels very close to the source are employed to treat tissues within the arterial wall. This article covers basic physics of radioactivity and differentiates between beta and gamma radiations. Physical parameters such as activity, half-life, exposure and absorbed dose have been explained. Finally, the dose distribution around a point source and a linear source is described. The principles of basic physics are likely to play an important role in shaping the emerging technology and its application in vascular brachytherapy.
Nutritive Supplements - Help or Harm for Breast Cancer Patients?
Muenstedt, Karsten; El-Safadi, Samer
2010-01-01
SUMMARY: Considerable numbers of patients and physicians believe that micronutrients may be useful with respect to prevention and treatment of breast cancer. However, the analysis of the literature shows that basic information on nutritional demands in cancer patients is lacking. It is unknown whether there is an increased demand of micro-nutrients in cancer patients in general and if there is an even more increased demand during the various types of treatment. As a result, there are only limited positive findings. Higher calcium intake in premenopausal women and higher intake of vitamin D seem to be able to lower breast cancer incidence. Vitamin E (800 IU per day) was found to have a modest effect on hot flashes during tamoxifen treatment. However, there are potential side effects especially when micronutrients are administered in high or very high doses. There is increasing evidence that dose-effect relationships are not linear but U-shaped. It seems that two thresholds exist for adverse effect, one at low doses for undersupply, and another at high doses for toxicity. Thus, arbitrary high-dose administration of micronutrients should be avoided. Supplementation of normal doses seems to be safe and acceptable from the medical point of view.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boerner, A. J.; Maldonado, D. G.; Hansen, Tom
2012-09-01
Environmental assessments and remediation activities are being conducted by the U.S. Department of Energy (DOE) at the Paducah Gaseous Diffusion Plant (PGDP), Paducah, Kentucky. The Oak Ridge Institute for Science and Education (ORISE), a DOE prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct radiation dose modeling analyses and derive single radionuclide soil guidelines (soil guidelines) in support of the derivation of Authorized Limits (ALs) for 'DOE-Owned Property Outside the Limited Area' ('Property') at the PGDP. The ORISE evaluation specifically included the area identified by DOE restricted area postings (public use access restrictions) and areas licensedmore » by DOE to the West Kentucky Wildlife Management Area (WKWMA). The licensed areas are available without restriction to the general public for a variety of (primarily) recreational uses. Relevant receptors impacting current and reasonably anticipated future use activities were evaluated. In support of soil guideline derivation, a Conceptual Site Model (CSM) was developed. The CSM listed radiation and contamination sources, release mechanisms, transport media, representative exposure pathways from residual radioactivity, and a total of three receptors (under present and future use scenarios). Plausible receptors included a Resident Farmer, Recreational User, and Wildlife Worker. single radionuclide soil guidelines (outputs specified by the software modeling code) were generated for three receptors and thirteen targeted radionuclides. These soil guidelines were based on satisfying the project dose constraints. For comparison, soil guidelines applicable to the basic radiation public dose limit of 100 mrem/yr were generated. Single radionuclide soil guidelines from the most limiting (restrictive) receptor based on a target dose constraint of 25 mrem/yr were then rounded and identified as the derived soil guidelines. An additional evaluation using the derived soil guidelines as inputs into the code was also performed to determine the maximum (peak) dose for all receptors. This report contains the technical basis in support of the DOE?s derivation of ALs for the 'Property.' A complete description of the methodology, including an assessment of the input parameters, model inputs, and results is provided in this report. This report also provides initial recommendations on applying the derived soil guidelines.« less
Pentreath, R J; Woodhead, D S
2001-09-28
In order to demonstrate, explicitly, that the environment can be protected with respect to controlled sources of ionising radiation, it is essential to have a systematic framework within which dosimetry models for fauna and flora can be used. And because of the practical limitations on what could reasonably be modelled and the amount of information that could reasonably be obtained, it is also necessary to limit the application of such models to a 'set' of fauna and flora within a reference' context. This paper, therefore, outlines the factors that will need to be considered to select such 'reference' fauna and flora, and describes some of the factors and constraints necessary to develop the associated dosimetry models. It also describes some of the most basic environmental geometrics within which the dose models could be set in order to make comparisons amongst different radiation sources.
Research on radiation exposure from CT part of hybrid camera and diagnostic CT
NASA Astrophysics Data System (ADS)
Solný, Pavel; Zimák, Jaroslav
2014-11-01
Research on radiation exposure from CT part of hybrid camera in seven different Departments of Nuclear Medicine (DNM) was conducted. Processed data and effective dose (E) estimations led to the idea of phantom verification and comparison of absorbed doses and software estimation. Anonymous data from about 100 examinations from each DNM was gathered. Acquired data was processed and utilized by dose estimation programs (ExPACT, ImPACT, ImpactDose) with respect to the type of examination and examination procedures. Individual effective doses were calculated using enlisted programs. Preserving the same procedure in dose estimation process allows us to compare the resulting E. Some differences and disproportions during dose estimation led to the idea of estimated E verification. Consequently, two different sets of about 100 of TLD 100H detectors were calibrated for measurement inside the Aldersnon RANDO Anthropomorphic Phantom. Standard examination protocols were examined using a 2 Slice CT- part of hybrid SPECT/CT. Moreover, phantom exposure from body examining protocol for 32 Slice and 64 Slice diagnostic CT scanner was also verified. Absorbed dose (DT,R) measured using TLD detectors was compared with software estimation of equivalent dose HT values, computed by E estimation software. Though, only limited number of cavities for detectors enabled measurement within the regions of lung, liver, thyroid and spleen-pancreas region, some basic comparison is possible.
Mitra, A; Fadda, H M
2014-08-04
The purpose of this study was to investigate the influence of gastric emptying patterns, surfactants, and dosage form on the supersaturation of a poorly soluble weakly basic drug, dipyridamole, using an in vitro model mimicking the dynamic environment of the upper gastrointestinal tract, and, furthermore, to evaluate the usefulness of this model in establishing correlations to in vivo bioavailability for drugs with solubility/dissolution limited absorption. A simulated stomach duodenum model comprising four compartments was used to assess supersaturation and precipitation kinetics as a function of time. It integrates physiologically relevant fluid volumes, fluid transfer rates, and pH changes of the upper GI tract. Monoexponential gastric emptying patterns simulating the fasted state were compared to linear gastric emptying patterns simulating the fed state. The effect of different surfactants commonly used in oral preparations, specifically, sodium lauryl sulfate (SLS), poloxamer-188, and polysorbate-80, on dipyridamole supersaturation was investigated while maintaining surface tension of the simulated gastric fluids at physiological levels and without obtaining artificial micellar solubilization of the drug. The supersaturation behavior of different dose strengths of dipyridamole was explored. Significant levels of dipyridamole supersaturation were observed in the duodenal compartment under all the different in vivo relevant conditions explored. Dipyridamole supersaturation ratios of up to 11-fold have been observed, and supersaturation has been maintained for up to 120 min. Lower duodenal concentrations of dipyridamole were observed under linear gastric emptying patterns compared to mononexponential gastric emptying. The mean duodenal area under concentration-time curves (AUC60min) for the dipyridamole concentration profile in the duodenal compartment is significantly different for all the surfactants explored (P < 0.05). Our investigations with the different surfactants and comparison of dosage form (solution versus suspension) on the precipitation of dipyridamole revealed that crystal growth, rather than nucleation, is the rate-limiting step for the precipitation of dipyridamole. A linear dose-response relationship was found for the mean in vitro duodenal area under concentration-time curves (AUC∞) in the dose range of 25 mg to 100 mg (R(2) = 0.886). This is in agreement with the pharmacokinetic data of dipyridamole reported in the literature. The simulated stomach duodenum model can provide a reliable and discriminative screening tool for exploring the effect of different physiological variables or formulations on the supersaturation/precipitation kinetics of weakly basic drugs with solubility limited absorption. The amount of drug in solution in the duodenal compartment of the SSD correlates to bioavailability for the weakly basic drug, dipyridamole, which has solubility limited absorption and undergoes supersaturation/precipitation.
Brodecki, Marcin; Domienik, Joanna U; Zmyślony, Marek
2012-01-01
The current system of dosimetric quantities has been defined by the International Commission on Radiological Protection (ICRP) and the International Commission on Radiation Units and Measurements (ICRU). Complexity of the system implies the physical nature of ionizing radiation, resulting from the presence of different types of radiation of different ionization capabilities, as well as the individual radiation sensitivity of biological material exposed. According to the latest recommendations, there are three types of dosimeter quantities relevant to radiation protection and radiological assessment of occupational exposure. These are the basic quantities, safety quantities and operational quantities. Dose limits for occupational exposure relate directly to the protection quantities, i.e. the equivalent dose and effective dose, while these quantities are practically unmeasurable in real measurement conditions. For this reason, in the system of dosimetric quantities directly measurable operating volumes were defined. They represent equivalents of the protection quantities that allow for a reliable assessment of equivalent and effective dose by conducting routine monitoring of occupational exposure. This paper presents the characteristics of these quantities, their relationships and importance in assessing individual effects of radiation. Also the methods for their implementation in personal and environmental dosimetry were showcased. The material contained in the article is a compendium of essential information about dosimetric quantities with reference to the contemporary requirements of the law, including the changed annual occupational exposure limit for the lens of the eye. The material is especially addressed to those responsible for dosimetry monitoring in the workplace, radiation protection inspectors and occupational health physicians.
Measurement of 238U and 232Th radionuclides in ilmenite and synthetic rutile
NASA Astrophysics Data System (ADS)
Idris, M. I.; Siong, K. K.; Fadzil, S. M.
2018-01-01
The only factory that currently processes ilmenite to produce synthetic rutile is Tor Minerals in Ipoh, Perak, Malaysia. These two minerals contain radioactive elements such as uranium and thorium. Furthermore, this factory was built close to the residential areas. Thus, the primary issues are radiation exposure attributed to the decay of the radionuclides. Hence, the objectives of this study are to measure the dose and to evaluate activity levels of uranium and thorium. Dose rates from surrounding area of factory indicate the normal range for both on the surface and 1 meter above the ground (0.3-0.7 μSv/hr) lower than the global range of 0.5-1.3 μSv/hr set by UNSCEAR. The mean activity levels of uranium and thorium for ilmenite are 235 Bq/kg and 503 Bq/kg while for synthetic rutile are 980 Bq/kg and 401 Bq/kg, respectively. The result shows that uranium activity levels of synthetic rutile is 4 times higher than ilmenite but it is still lower than the regulatory exemption limit of 1000 Bq/kg set by IAEA Basic Safety Standards. Even though the dose rates at the factory and the activity levels are within safe limits, safety precautions must be followed by the factory management to prevent any unwanted accident to occur.
Hartmann, Josefin; Distler, Florian A; Baumueller, Martin; Guni, Ewald; Pahernik, Sascha A; Wucherer, Michael
2018-06-14
Due to new radiobiological data, the ICRP recommends a dose limit of 20mSv per year to the eye lens. Therefore, the IAEA International Basic Safety Standard and the EU council directive 2013/59/EURATOM requires a reduction of the annual dose limit from 150mSv to 20mSv. Urologists are exposed to an elevated radiation exposure in the head region during fluoroscopic interventions, due to the commonly used overtable X-ray tubes and the rarely used radiation protection for the head. Aim of the study was to analyze real radiation exposure to the eye lens of the urologist during various interventions during which the patient is in the lithotomy position. The partial body doses (forehead and apron collar) of the urologists and surgical staff were measured over a period of two months. 95 interventions were performed on Uroskop Omnia Max workplaces (Siemens Healthineers, Erlangen, Germany). Interventions were class-divided in less (stage I) and more complex (stage II) interventions. Two dosimeter-types were applied: well-calibrated electronic personal dosimeter EPD Mk2 and self-calibrated TLD-100H (both Thermo Fisher Scientific, Waltham, USA). The radiation exposure parameters were documented using the dose area product (DAP) and the fluoroscopy time (FT). The correlation between DAP and the apron dose of the urologist was in average 0.07µSv per 1µGym². The more experienced urologists yielded a mean DAP of 166µGym² for stage I and 415µGym² for stage II procedures. The interventionist was exposed with 10µSv in mean outside the lead apron collar. The mean dose value of the eye lenses per intervention was ascertained to 20µSv (mean DAP: 233µGym²). The study setup allows a differentiated and time-resolved measurement of the radiation exposure, which was found heterogeneous depending on intervention and surgeon. In this setting, approximately 1000 interventions can be performed until the annual eye lens dose limit is achieved.
Kiang, Juliann G; Smith, Joan T; Hegge, Sara R; Ossetrova, Natalia I
2018-06-01
Exposure to ionizing radiation is a crucial life-threatening factor in nuclear and radiological incidents. It is known that ionizing radiation affects cytokine/chemokine concentrations in the blood of B6D2F1 mice. It is not clear whether radiation dose rates would vary the physiological response. Therefore, in this study we utilized data from two experiments using B6D2F1 female mice exposed to six different dose rates ranging from low to high rates. In one experiment, mice received a total dose of 8 Gy (LD 0/30 ) of 60 Co gamma radiation at four dose rates: 0.04, 0.15, 0.30 and 0.47 Gy/min. Blood samples from mice were collected at 24 and 48 h postirradiation for cytokine/chemokine measurements, including interleukin (IL)-1β, IL-6, IL-10, keratinocyte cytokine (KC), IL-12p70, IL-15, IL-17A, IL-18, granulocyte-colony stimulating factor (G-CSF), granulocyte macrophage (GM)-CSF, macrophage (M)-CSF, monokine induced by gamma interferon (MIG), tumor necrosis factor (TNF)-α, fibroblast growth factor (FGF)-basic, vascular endothelial growth factor (VEGF) and platelet-derived growth factor basic (PDGF-bb). At 24 h after ionizing irradiation at dose rate of 0.04 Gy/min, significant increases were observed only in G-CSF and M-CSF ( P < 0.05). At 0.15 Gy/min, IL-10, IL-17A, G-CSF and GM-CSF concentrations were increased. At 0.3 Gy/min, IL-15, IL-18, G-CSF, GM-CSF, M-CSF, MCP-1, MIP-2, MIG, FGF-basic, VEGF and PDGF-bb were significantly elevated ( P < 0.05). At 0.47 Gy/min, IL-6, KC, IL-10, MCP-1, G-CSF, GM-CSF and M-CSF were significantly increased. At 48 h postirradiation, all cytokines/chemokines except MCP-1 returned to or were below their baselines, suggesting these increases are transient at LD 0/30 irradiation. Of note, there is a limitation on day 2 because cytokines/chemokines are either at or below their baselines. Other parameters such as fms-like tyrosine kinase receptor-3 ligand (Flt-3 ligand) concentrations and lymphocyte counts, which have proven to be unaffected by radiation dose rates, can be used instead for assessing the radiation dose. However, in a separate radiation dose and time-course experiment, increases in IL-18 and G-CSF depended on the radiation doses but showed no significant differences between 0.58 and 1.94 Gy/min ( P > 0.05) at 3 and 6 Gy but not 12 Gy. G-CSF continued to increase up to day 7, whereas IL-18 increased on day 4 and remained above baseline level on day 7. Therefore, time after irradiation at different doses should be taken into consideration. To our knowledge, these results are the first to suggest that ionizing radiation, even at a very low-dose-rate (0.04 Gy/min), induces circulating G-CSF increases but not others for selected time points; radiation-induced increases in IL-18 at radiation dose rates between 0.15 and 1.94 Gy/min are also not in a radiation dose-rate-dependent manner. C-CSF, lymphocyte counts and circulating Flt-3 ligand should be explored further as possible biomarkers of radiation exposure at early time points. IL-18 is also worthy of further study as a potential biomarker at later time points.
SU-F-J-200: An Improved Method for Event Selection in Compton Camera Imaging for Particle Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mackin, D; Beddar, S; Polf, J
2016-06-15
Purpose: The uncertainty in the beam range in particle therapy limits the conformality of the dose distributions. Compton scatter cameras (CC), which measure the prompt gamma rays produced by nuclear interactions in the patient tissue, can reduce this uncertainty by producing 3D images confirming the particle beam range and dose delivery. However, the high intensity and short time windows of the particle beams limit the number of gammas detected. We attempt to address this problem by developing a method for filtering gamma ray scattering events from the background by applying the known gamma ray spectrum. Methods: We used a 4more » stage Compton camera to record in list mode the energy deposition and scatter positions of gammas from a Co-60 source. Each CC stage contained a 4×4 array of CdZnTe crystal. To produce images, we used a back-projection algorithm and four filtering Methods: basic, energy windowing, delta energy (ΔE), or delta scattering angle (Δθ). Basic filtering requires events to be physically consistent. Energy windowing requires event energy to fall within a defined range. ΔE filtering selects events with the minimum difference between the measured and a known gamma energy (1.17 and 1.33 MeV for Co-60). Δθ filtering selects events with the minimum difference between the measured scattering angle and the angle corresponding to a known gamma energy. Results: Energy window filtering reduced the FWHM from 197.8 mm for basic filtering to 78.3 mm. ΔE and Δθ filtering achieved the best results, FWHMs of 64.3 and 55.6 mm, respectively. In general, Δθ filtering selected events with scattering angles < 40°, while ΔE filtering selected events with angles > 60°. Conclusion: Filtering CC events improved the quality and resolution of the corresponding images. ΔE and Δθ filtering produced similar results but each favored different events.« less
NASA Astrophysics Data System (ADS)
Ingale, S. V.; Datta, D.
2010-10-01
Consequence of the accidental release of radioactivity from a nuclear power plant is assessed in terms of exposure or dose to the members of the public. Assessment of risk is routed through this dose computation. Dose computation basically depends on the basic dose assessment model and exposure pathways. One of the exposure pathways is the ingestion of contaminated food. The aim of the present paper is to compute the uncertainty associated with the risk to the members of the public due to the ingestion of contaminated food. The governing parameters of the ingestion dose assessment model being imprecise, we have approached evidence theory to compute the bound of the risk. The uncertainty is addressed by the belief and plausibility fuzzy measures.
High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography
NASA Astrophysics Data System (ADS)
Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; Yildirim, Ali Önder; Hertz, Hans M.
2016-12-01
X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.
Mairs, William DA
2016-06-01
The International Commission on Radiological Protection (ICRP) has recommended a 20 mSv year(-1) dose limit for the lens of the eye, which has been adopted in the European Union Basic Safety Standards. Interventional radiologists (IRs) and interventional cardiologists (ICs) are likely to be affected by this. The effects of radiation in the lens are somewhat uncertain, and the ICRP explicitly recommend optimization. Occupational dose constraints are part of the optimization process and define a level of dose which ought to be achievable in a well-managed practice. This commentary calls on the professional bodies to review a need for national constraints to guide local decisions. Consideration is given to developing such constraints using maximum expected doses in high-workload facilities with good radiation protection practices and application of a factor allowing for attenuation by lead glasses (LG). Doses are based on a Public Health England survey of eye dose in the UK. Maximum expected doses for ICs are approximately 21 mSv year(-1), neglecting LG. However, the extent of IR exposure is not yet fully known, and further evidence is required before conclusions are drawn. A Health and Safety Laboratory review of LG established a conservative dose reduction factor of 3 for models available in 2012. Application of this factor provides a dose constraint of 7 mSv year(-1) to the eye for ICs. To achieve this constraint, those employers with the most exposed ICs will have to provide and ensure the correct use of a ceiling-suspended eye shield and LG.
Radiation treatment of pharmaceuticals
NASA Astrophysics Data System (ADS)
Dám, A. M.; Gazsó, L. G.; Kaewpila, S.; Maschek, I.
1996-03-01
Product specific doses were calculated for pharmaceuticals to be radiation treated. Radio-pasteurization dose were determined for some heat sensitive pharmaceutical basic materials (pancreaton, neopancreatin, neopancreatin USP, duodenum extract). Using the new recommendation (ISO standards, Method 1) dose calculations were performed and radiation sterilization doses were determined for aprotinine and heparine Na.
Emergency Dosimetry Using Ceramic Components in Personal Electronic Devices
NASA Astrophysics Data System (ADS)
Kouroukla, E. C.; Bailiff, I. K.; Terry, I.
2014-02-01
The rapid assessment of radiation dose to members of the public exposed to significant levels of ionizing radiation during a radiological incident presents a significant difficulty in the absence of planned radiation monitoring. However, within most personal electronic devices components such as resistors with alumina substrates can be found that have potentially suitable properties as solid state dosimeters using luminescence measurement techniques. The suitability of several types of ceramic-based components (e.g., resonators, inductors and resistors) has been previously examined using optically stimulated luminescence (OSL) and thermoluminescence (TL) techniques to establish their basic characteristics for the retrospective determination of absorbed dose. In this paper, we present results obtained with aluminum oxide surface mount resistors extracted from mobile phones that further extend this work. Very encouraging results have been obtained related to the measurement of luminescence sensitivity, dose response, reusability, limit of detection, signal reproducibility and known-dose recovery. However, the alumina exhibits a rapid loss of the latent luminescence signal with time following irradiation attributed to athermal (or anomalous) fading. The issues related to obtaining a reliable correction protocol for this loss and the detailed examinations required of the fading behavior are discussed.
Acidic fibroblast growth factor (FGF) but not basic FGF induces sleep and fever in rabbits.
Knefati, M; Somogyi, C; Kapás, L; Bourcier, T; Krueger, J M
1995-07-01
Acidic fibroblast growth factor (FGF) and basic FGF belong to a growth factor family. Interleukin-1, another member of that family, is involved in sleep regulation. FGFs and interleukin-1 share structural and functional features. We therefore determined whether acidic FGF and basic FGF were somnogenic. Male New Zealand White rabbits were provided with electroencephalographic (EEG) electrodes, a brain thermistor, and a lateral intracerebroventricular (icv) cannula. The animals were injected icv with isotonic NaCl (control) and on separate days with one of three doses of acidic or basic FGF (0.01, 0.1, or 1.0 micrograms) or with heat-treated acidic FGF (1.0 micrograms). The EEG, brain temperature, and motor activity were recorded for 23 h. The biological activity of basic FGF was determined in vitro by its ability to induce DNA synthesis in rat aortic smooth muscle cells. Acidic FGF induced prolonged dose-related increases in non-rapid eye movement sleep beginning in the 1st postinjection h and continuing for 12-23 h after the treatment. Acidic FGF also induced fevers of approximately 1 degree C after the 1.0 micrograms dose. Both activities of acidic FGF were lost after heat treatment. In contrast, basic FGF lacked somnogenic and pyrogenic activity, although it did induce DNA synthesis. Current results suggest that acidic FGF is part of the complex cytokine network in brain involved in sleep regulation.
Watanabe, Yoichi; Warmington, Leighton; Gopishankar, N
2017-01-01
Accurate dose measurement tools are needed to evaluate the radiation dose delivered to patients by using modern and sophisticated radiation therapy techniques. However, the adequate tools which enable us to directly measure the dose distributions in three-dimensional (3D) space are not commonly available. One such 3D dose measurement device is the polymer-based dosimeter, which changes the material property in response to radiation. These are available in the gel form as polymer gel dosimeter (PGD) and ferrous gel dosimeter (FGD) and in the solid form as solid plastic dosimeter (SPD). Those are made of a continuous uniform medium which polymerizes upon irradiation. Hence, the intrinsic spatial resolution of those dosimeters is very high, and it is only limited by the method by which one converts the dose information recorded by the medium to the absorbed dose. The current standard methods of the dose quantification are magnetic resonance imaging, optical computed tomography, and X-ray computed tomography. In particular, magnetic resonance imaging is well established as a method for obtaining clinically relevant dosimetric data by PGD and FGD. Despite the likely possibility of doing 3D dosimetry by PGD, FGD or SPD, the tools are still lacking wider usages for clinical applications. In this review article, we summarize the current status of PGD, FGD, and SPD and discuss the issue faced by these for wider acceptance in radiation oncology clinic and propose some directions for future development. PMID:28396725
High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre
X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-powermore » small-spot liquid-metal-jet electron-impact source. Lastly, the tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.« less
Cases of ergotism in livestock and associated ergot alkaloid concentrations in feed
NASA Astrophysics Data System (ADS)
Craig, A.; Klotz, James; Duringer, Jennifer
2015-02-01
Ergot-induced disease was known long before Biblical times and has been the root cause for countless human epidemics spanning from the early fourteenth century to the late sixteenth century. In contrast, many of these same ergot alkaloids have been utilized for their medicinal properties to mitigate migraine headaches and have had indications as anticarcinogens. Although ergot alkaloids have been used for centuries, basic pharmacokinetic data has not been documented for clinical disease. Consequently, a threshold dose and accurate dose-response data have yet to be established. Throughout the past several years, new detection techniques have emerged to detect these alkaloids at the parts per billion which have allowed for new efforts to be made with respect to determining threshold levels and making accurate clinical diagnoses. This perspectives article provides a critical initial step for establishing a uniform interpretation of ergot toxicosis from limited existing data.
High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography
Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; ...
2016-12-13
X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-powermore » small-spot liquid-metal-jet electron-impact source. Lastly, the tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.« less
Eslamy, Hedieh K; Newman, Beverley; Weinberger, Ed
2014-12-01
A quality improvement (QI) program may be implemented using the plan-do-study-act cycle (as a model for making improvements) and the basic QI tools (used to visually display and analyze variation in data). Managing radiation dose has come to the forefront as a safety goal for radiology departments. This is especially true in the pediatric population, which is more radiosensitive than the adult population. In this article, we use neonatal digital radiography to discuss developing a QI program with the principle goals of decreasing the radiation dose, decreasing variation in radiation dose, and optimizing image quality. Copyright © 2014 Elsevier Inc. All rights reserved.
Walker, Edward D.
2016-01-01
Abstract Ammonium and sulfide in water of tree hole and tire habitats of Aedes triseriatus Say larvae could accumulate to toxic levels, limiting growth and production of larvae and adults. Both ions were detected in water samples taken in longitudinal series over 11 dates from 10 habitats of each type during the larval growth season, at concentrations suggestive of reducing conditions in these habitats. Ammonium was more concentrated overall in water of both habitat types, while sulfide was more concentrated in tires than in tree holes. Water of tree holes was more acidic, whereas water in tires tended to be more basic, an important difference relative to the tendency of ammonium to form the more toxic ammonia moiety under basic conditions. Oxygen saturation was low in both habitat types, indicative of hypoxic conditions such that aerobic respiration would be limited. First-and fourth-instar larvae were sensitive to ammonium and sulfide in acute dose-response assays, but LC50 values were above maximum concentrations observed under field conditions, suggesting that toxic effects of ammonium and sulfide on larvae are not acute, but could be chronic. PMID:27049027
SU-E-P-10: Establishment of Local Diagnostic Reference Levels of Routine Exam in Computed Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, M; Wang, Y; Weng, H
Introduction National diagnostic reference levels (NDRLs) can be used as a reference dose of radiological examination can provide radiation dose as the basis of patient dose optimization. Local diagnostic reference levels (LDRLs) by periodically view and check doses, more efficiency to improve the way of examination. Therefore, the important first step is establishing a diagnostic reference level. Computed Tomography in Taiwan had been built up the radiation dose limit value,in addition, many studies report shows that CT scan contributed most of the radiation dose in different medical. Therefore, this study was mainly to let everyone understand DRL’s international status. Formore » computed tomography in our hospital to establish diagnostic reference levels. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). Each exam each different body part, we collect 10 patients at least. Carried out the routine examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. Results: The majority of patients (75%) were between 60–70 Kg of body weight. There are 25 examinations in this study. Table 1 shows the LDRL of each CT routine examination. Conclusions: Therefore, this study would like to let everyone know DRL’s international status, but also establishment of computed tomography of the local reference levels for our hospital, and providing radiation reference, as a basis for optimizing patient dose.« less
10 CFR 20.1207 - Occupational dose limits for minors.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Occupational dose limits for minors. 20.1207 Section 20.1207 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1207 Occupational dose limits for minors. The annual occupational dose limits for minors are...
10 CFR 20.1207 - Occupational dose limits for minors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Occupational dose limits for minors. 20.1207 Section 20.1207 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1207 Occupational dose limits for minors. The annual occupational dose limits for minors are...
10 CFR 20.1207 - Occupational dose limits for minors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Occupational dose limits for minors. 20.1207 Section 20.1207 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1207 Occupational dose limits for minors. The annual occupational dose limits for minors are...
10 CFR 20.1207 - Occupational dose limits for minors.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Occupational dose limits for minors. 20.1207 Section 20.1207 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1207 Occupational dose limits for minors. The annual occupational dose limits for minors are...
10 CFR 20.1207 - Occupational dose limits for minors.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Occupational dose limits for minors. 20.1207 Section 20.1207 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1207 Occupational dose limits for minors. The annual occupational dose limits for minors are...
42 CFR 82.2 - What are the basics of dose reconstruction?
Code of Federal Regulations, 2012 CFR
2012-10-01
... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES METHODS FOR CONDUCTING DOSE RECONSTRUCTION UNDER THE... this exposure environment. Then methods are applied to translate exposure to radiation into quantified... workers. A hierarchy of methods is used in a dose reconstruction, depending on the nature of the exposure...
42 CFR 82.2 - What are the basics of dose reconstruction?
Code of Federal Regulations, 2013 CFR
2013-10-01
... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES METHODS FOR CONDUCTING DOSE RECONSTRUCTION UNDER THE... this exposure environment. Then methods are applied to translate exposure to radiation into quantified... workers. A hierarchy of methods is used in a dose reconstruction, depending on the nature of the exposure...
[Doses to organs at risk in conformational and stereotactic body radiation therapy: Liver].
Debbi, K; Janoray, G; Scher, N; Deutsch, É; Mornex, F
2017-10-01
The liver is an essential organ that ensures many vital functions such as metabolism of bilirubin, glucose, lipids, synthesis of coagulation factors, destruction of many toxins, etc. The hepatic parenchyma can be irradiated during the management of digestive tumors, right basithoracic, esophagus, abdomen in toto or TBI. In addition, radiotherapy of the hepatic area, which is mainly stereotactic, now occupies a central place in the management of primary or secondary hepatic tumors. Irradiation of the whole liver, or part of it, may be complicated by radiation-induced hepatitis. It is therefore necessary to respect strict dosimetric constraints both in stereotactic and in conformational irradiation in order to limit the undesired irradiation of the hepatic parenchyma which may vary according to the treatment techniques, the basic hepatic function or the lesion size. The liver is an organ with a parallel architecture, so the average tolerable dose in the whole liver should be considered rather than the maximum tolerable dose at one point. The purpose of this article is to propose a development of dose recommendations during conformation or stereotactic radiotherapy of the liver. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
NASA Technical Reports Server (NTRS)
Rogozkin, V. D.; Chertkov, K. S.; Nikolov, I.
1974-01-01
The basic characteristics of prolonged radiation - increased tolerance of radiation injury - are attributed to cellular kinetics; as dose rate is reduced, the population rate is not disturbed, particularly that of stem cells which makes it possible for the organism to tolerate higher radiation loads. It is concluded that this effect makes approved radio protectors, whose effect contains an established cytostatic component, unsuitable for prolonged radiation. It is better to correct the stem pool formation process by either accelerating the proliferation of cells or limiting the effect of stimuli causing cells to lose colony forming properties.
Total Dose Effects in Conventional Bipolar Transistors
NASA Technical Reports Server (NTRS)
Johnston, A. H.; Swift, G. W.; Rax, B. G.
1994-01-01
This paper examines various factors in bipolar device construction and design, and discusses their impact on radiation hardness. The intent of the paper is to improve understanding of the underlying mechanisms for practical devices without special test structures, and to provide (1) guidance in ways to select transistor designs that are more resistant to radiation damage, and (2) methods to estimate the maximum amount of damage that might be expected from a basic transistor design. The latter factor is extremely important in assessing the risk that future lots of devices will be substantially below design limits, which are usually based on test data for older devices.
Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.
Duong, Phuong-Anh; Little, Brent P
2014-08-01
Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.
Physical interactions of charged particles for radiotherapy and space applications.
Zeitlin, Cary
2012-11-01
In this paper, the basic physics by which energetic charged particles deposit energy in matter is reviewed. Energetic charged particles are used for radiotherapy and are encountered in spaceflight, where they pose a health risk to astronauts. They interact with matter through nuclear and electromagnetic forces. Deposition of energy occurs mostly along the trajectory of the incoming particle, but depending on the type of incident particle and its energy, there is some nonzero probability for energy deposition relatively far from the nominal trajectory, either due to long-ranged knock-on electrons (sometimes called delta rays) or from the products of nuclear fragmentation, including neutrons. In the therapy setting, dose localization is of paramount importance, and the deposition of energy outside nominal treatment volumes complicates planning and increases the risk of secondary cancers as well as noncancer effects in normal tissue. Statistical effects are also important and will be discussed. In contrast to radiation therapy patients, astronauts in space receive comparatively small whole-body radiation doses from energetic charged particles and associated secondary radiation. A unique aspect of space radiation exposures is the high-energy heavy-ion component of the dose. This is not present in terrestrial exposures except in carbon-ion radiotherapy. Designers of space missions must limit exposures to keep risk within acceptable limits. These limits are, at present, defined for low-Earth orbit, but not for deep-space missions outside the geomagnetosphere. Most of the uncertainty in risk assessment for such missions comes from the lack of understanding of the biological effectiveness of the heavy-ion component, with a smaller component due to uncertainties in transport physics and dosimetry. These same uncertainties are also critical in the therapy setting.
Kumar, Deepak; Singh, Anshuman; Jha, Rishi Kumar
2018-04-21
Investigation of presence of Uranium (U) in groundwater/drinking water is an active are of research due to its chemical and radiological toxicity as well as long-term health effects. The current study had the objective of estimating U as a naturally occurring radioactive element in groundwater samples and assessment of ingestion dose, when groundwater is the source of drinking water. The random sampling method was chosen for the collection of samples based on population density. The estimation of U was done using LED fluorimeter. Statistical tools were applied to analyze the data and its spatial distribution. The U concentrations in three blocks of urban Patna were well below the permissible limits suggested by different health agencies of the world. A correlation test was performed to analyze the association of U with other physiochemical parameters of water samples. It was found that the sulfate, chloride, calcium, hardness, alkalinity, TDS, salinity, and ORP were positively correlated, whereas fluoride, phosphate, magnesium, dissolved oxygen, and pH were negatively correlated with U concentrations. The ingestion dose due to U, occurring in groundwater, was found to vary from 0.2-27.0 μSv y -1 with a mean of 4.2 μSv y - 1 , which was well below the recommended limit of 0.1 mSv (WHO WHO Chron 38:104-108, 2012).Therefore, the water in this region is fit for drinking purposes.
A two-dimensional biased coin design for dual-agent dose-finding trials.
Sun, Zhichao; Braun, Thomas M
2015-12-01
Given the limited efficacy observed with single agents, there is growing interest in Phase I clinical trial designs that allow for identification of the maximum tolerated combination of two agents. Existing parametric designs may suffer from over- or under-parameterization. Thus, we have designed a nonparametric approach that can be easily understood and implemented for combination trials. We propose a two-stage adaptive biased coin design that extends existing methods for single-agent trials to dual-agent dose-finding trials. The basic idea of our design is to divide the entire trial into two stages and apply the biased coin design, with modification, in each stage. We compare the operating characteristics of our design to four competing parametric approaches via simulation in several numerical examples. Under all simulation scenarios we have examined, our method performs well in terms of identification of the maximum tolerated combination and allocation of patients relative to the performance of its competitors. In our design, stopping rule criteria and the distribution of the total sample size among the two stages are context-dependent, and both need careful consideration before adopting our design in practice. Efficacy is not a part of the dose-assignment algorithm, nor used to define the maximum tolerated combination. Our design inherits the favorable statistical properties of the biased coin design, is competitive with existing designs, and promotes patient safety by limiting patient exposure to toxic combinations whenever possible. © The Author(s) 2015.
Ohno, Yumiko; Torikoshi, Masami; Suzuki, Masao; Umetani, Keiji; Imai, Yasuhiko; Uesugi, Kentaro; Yagi, Naoto
2008-07-01
A multislit collimator was designed and fabricated for basic studies on microbeam radiation therapy (MRT) with an x-ray energy of about 100 keV. It consists of 30 slits that are 25 microm high, 30 mm wide, and 5 mm thick in the beam direction. The slits were made of 25 microm-thick polyimide sheets that were separated by 175 microm-thick tungsten sheets. The authors measured the dose distribution of a single microbeam with a mean energy of 125 keV by a scanning slit method using a phosphor coupled to a charge coupled device camera and found that the ratios of the dose at the center of a microbeam to that at midpositions to adjacent slits were 1050 and 760 for each side of the microbeam. This dose distribution was well reproduced by the Monte Carlo simulation code PHITS.
43 CFR 2.19 - When may the bureau extend the basic time limit?
Code of Federal Regulations, 2014 CFR
2014-10-01
... 43 Public Lands: Interior 1 2014-10-01 2014-10-01 false When may the bureau extend the basic time... INFORMATION ACT; RECORDS AND TESTIMONY Timing of Responses to Requests § 2.19 When may the bureau extend the basic time limit? (a) The bureau may extend the basic time limit if unusual circumstances exist. Before...
Wilson, Lydia J; Newhauser, Wayne D
2015-01-01
State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 minutes. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models. PMID:26040833
Jagetic, Lydia J; Newhauser, Wayne D
2015-06-21
State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 min. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models.
21 CFR 320.27 - Guidelines on the design of a multiple-dose in vivo bioavailability study.
Code of Federal Regulations, 2011 CFR
2011-04-01
... vivo bioavailability study. 320.27 Section 320.27 Food and Drugs FOOD AND DRUG ADMINISTRATION... Guidelines on the design of a multiple-dose in vivo bioavailability study. (a) Basic principles. (1) In... labeling of the test product. (3) A multiple-dose study may be required to determine the bioavailability of...
Cone beam computed tomography in paediatric dentistry: overview of recent literature.
Aps, J K M
2013-06-01
The use of cone beam computed tomography (CBCT) in paediatric dentistry has been mentioned in numerous publications and case reports. The indications for the use of CBCT in paediatric dentistry, however, have not yet been properly addressed. On the other hand, the three basic principles of radiation protection (justification, limitation and optimisation) should suffice. A review of the current literature was used to assess the indications and contra-indications for the use of CBCT in paediatric dentistry. Paramount is the fact that CBCT generates a higher effective dose to the tissues than traditional dental radiographic exposures do. The effective radiation dose should not be underestimated, especially not in children, who are much more susceptible to stochastic biological effects. The thyroid gland in particular should be kept out of the primary beam as much as possible. As with any other radiographical technique, routine use of CBCT is not acceptable clinical practice. CBCT certainly has a place in paediatric dentistry, but its use must be justified on a patient case individual basis.
Particle Radiation Therapy for Gastrointestinal Malignancies
Meyer, Jeffrey J.; Willett, Christopher G.
2007-01-01
Treatment-related toxicity is common in the radiotherapeutic management of cancers of the gastrointestinal tract. These toxicities can diminish treatment efficacy by necessitating treatment breaks, limiting the radiation dose that can be delivered, and hindering concomitant use of chemotherapy and targeted drug agents. Many efforts have focused on widening the gap between the likelihood of tumor control and the likelihood of toxicities associated with radiation. Use of particles that exhibit a Bragg peak phenomenon in their interactions with tissue, such as protons, heavier ions like carbon ions, and pions, is one means of concentrating radiation dose in tumors and away from normal tissues. Neutron beams have also been used in the treatment of gastrointestinal cancers in an effort to take advantage of their potent biologic effects. This report reviews basic particle radiation physics and biology, as well as the clinical experience with protons, heavier ions, pions, and neutrons in the treatment of various gastrointestinal malignancies. Potential future directions in clinical research with particle therapy are discussed. PMID:19360149
10 CFR 835.207 - Occupational dose limits for minors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Occupational dose limits for minors. 835.207 Section 835.207 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.207 Occupational dose limits for minors. The dose limits for minors occupationally exposed...
Evaluation of an artificial intelligence guided inverse planning system: clinical case study.
Yan, Hui; Yin, Fang-Fang; Willett, Christopher
2007-04-01
An artificial intelligence (AI) guided method for parameter adjustment of inverse planning was implemented on a commercial inverse treatment planning system. For evaluation purpose, four typical clinical cases were tested and the results from both plans achieved by automated and manual methods were compared. The procedure of parameter adjustment mainly consists of three major loops. Each loop is in charge of modifying parameters of one category, which is carried out by a specially customized fuzzy inference system. A physician prescribed multiple constraints for a selected volume were adopted to account for the tradeoff between prescription dose to the PTV and dose-volume constraints for critical organs. The searching process for an optimal parameter combination began with the first constraint, and proceeds to the next until a plan with acceptable dose was achieved. The initial setup of the plan parameters was the same for each case and was adjusted independently by both manual and automated methods. After the parameters of one category were updated, the intensity maps of all fields were re-optimized and the plan dose was subsequently re-calculated. When final plan arrived, the dose statistics were calculated from both plans and compared. For planned target volume (PTV), the dose for 95% volume is up to 10% higher in plans using the automated method than those using the manual method. For critical organs, an average decrease of the plan dose was achieved. However, the automated method cannot improve the plan dose for some critical organs due to limitations of the inference rules currently employed. For normal tissue, there was no significant difference between plan doses achieved by either automated or manual method. With the application of AI-guided method, the basic parameter adjustment task can be accomplished automatically and a comparable plan dose was achieved in comparison with that achieved by the manual method. Future improvements to incorporate case-specific inference rules are essential to fully automate the inverse planning process.
Neutron Skyshine Considerations For The NIF Shielding Design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, M S; Mecozzi, J M; Tobin, M T
2004-01-28
A series of coupled neutron-photon transport Monte-Carlo calculations was performed to estimate the roof shielding required to limit the skyshine dose to less than 1 mrem/y at the site boundary when conducting DT experiments with annual fusion yields up to 1200 MJ (4.2E20 neutrons/y). The NIF shielding design consists of many different components. The basic components include 10-cm-thick Al chamber with 40-cm-thick target chamber gunite shield having multiple penetrations, 1.83-m-thick concrete Target Bay walls, 1.37-m-thick concrete roof, and multiple concrete floors with numerous penetrations. Under this shielding configuration, the skyshine dose at the nearest site-boundary was calculated to be lessmore » than 0.2 mrem/y for all possible target illumination configurations. The potential dose at the site boundary would be about one-tenth of the cosmic neutron dose that we measured with bubble neutron detectors on board a commercial roundtrip flight from SF to Rochester. This incremental dose increase is well within the normal fluctuations (noise) of the natural background radiation in the Livermore area. The skyshine dose has no impact on the public. The skyshine dose trends at ground and elevated levels are plotted as a function of distance from 20 m to 1000 m from the center of the target bay. The differential neutron and photon energy flux emerging from the NIF roof and at several locations on the ground is plotted to show how it shifts with distance. The results of this study are compared with the neutron skyshine studies done at high-energy accelerators by R. H. Thomas.« less
Low Dose Risk, Decisions, and Risk Communication
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flynn, James
The overall research objective was to establish new levels of information about how people, groups, and communities respond to low dose radiation exposure. This is basic research into the social psychology of individual, group, and community responses to radiation exposures. The results of this research are directed to improving risk communication and public participation in management of environmental problems resulting from low dose radiation.
Terasaki, Kento; Fujibuchi, Toshioh; Toyoda, Takatoshi; Yoshida, Yutaka; Akasaka, Tsutomu; Nohtomi, Akihiro; Morishita, Junji
2016-12-01
The ionisation chamber for computed tomography (CT) is an instrument that is most commonly used to measure the computed tomography dose index. However, it has been reported that the 10 cm effective detection length of the ionisation chamber is insufficient due to the extent of the dose distribution outside the chamber. The purpose of this study was to estimate the basic characteristics of a plastic scintillating fibre (PSF) detector with a long detection length of 50 cm in CT radiation fields. The authors investigated position dependence using diagnostic X-ray equipment and dependencies for energy, dose rate and slice thickness using an X-ray CT system. The PSF detector outputs piled up at a count rate of 10 000 counts ms -1 in dose rate dependence study. With calibration, this detector may be useful as a CT dosemeter with a long detection length except for the measurement at high dose rate. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
TU-AB-207A-03: Image Quality, Dose, and Clinical Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, F.
Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid-changing advanced technologies given the two-hour time limit, but the fundamental principles discussed in this course may facilitatemore » better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X-ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in-depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off-focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross-talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel-beam, fan-beam, and cone-beam geometries will be discussed. To address the issue of radiation dose related to x-ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non-ideal conditions of major system components, image artifact often arise in the reconstructed images. Because of the limited scope of this course, only major imaging artifacts, their appearance, and possible mitigation and corrections will be discussed. Assessment of the performance of a CT scanner is a complicated subject. Procedures to measure common image quality metrics such as high contrast spatial resolution, low contrast detectability, and slice profile will be described. The reason why these metrics used for FBP may not be sufficient for statistical iterative reconstruction will be explained. Optimizing radiation dose requires comprehension of CT dose metrics. This course will briefly describe various dose metrics, and interaction with acquisition parameters and patient habitus. CT is among the most frequently used imaging tools due to its superior image quality, easy to operate, and a broad range of applications. This course will present several interesting CT applications such as a mobile CT unit on an ambulance for stroke patients, low dose lung cancer screening, and single heartbeat cardiac CT. Learning Objectives: Understand the function and impact of major components of X-ray tube on the image quality. Understand the function and impact of major components of CT detector on the image quality. Be familiar with the basic procedure of CT image reconstruction. Understand the effect of image reconstruction on CT image quality and artifacts. Understand the root causes of common CT image artifacts. Be familiar with image quality metrics especially high and low contrast resolution, noise power spectrum, slice sensitivity profile, etc. Understand why basic image quality metrics used for FBP may not be sufficient to characterize the performance of advanced iterative reconstruction. Be familiar with various CT dose metrics and their interaction with acquisition parameters. New development in advanced CT clinical applications. JH: Employee of GE Healthcare. FD: No disclosure.; J. Hsieh, Jiang Hsieh is an employee of GE Healthcare.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohno, Yumiko; Torikoshi, Masami; Suzuki, Masao
A multislit collimator was designed and fabricated for basic studies on microbeam radiation therapy (MRT) with an x-ray energy of about 100 keV. It consists of 30 slits that are 25 {mu}m high, 30 mm wide, and 5 mm thick in the beam direction. The slits were made of 25 {mu}m-thick polyimide sheets that were separated by 175 {mu}m-thick tungsten sheets. The authors measured the dose distribution of a single microbeam with a mean energy of 125 keV by a scanning slit method using a phosphor coupled to a charge coupled device camera and found that the ratios of themore » dose at the center of a microbeam to that at midpositions to adjacent slits were 1050 and 760 for each side of the microbeam. This dose distribution was well reproduced by the Monte Carlo simulation code PHITS.« less
Gumińska, Jolanta; Kłos, Marcin
2015-01-01
Filtration efficiency in a conventional water treatment system was analyzed in the context of pre-hydrolyzed coagulant overdosing. Two commercial coagulants of different aluminum speciation were tested. A study was carried out at a water treatment plant supplied with raw water of variable quality. The lack of stability of water quality caused many problems with maintaining the optimal coagulant dose. The achieved results show that the type of coagulant had a very strong influence on the effectiveness of filtration resulting from the application of an improper coagulant dose. The overdosing of high basicity coagulant (PAC85) caused a significant increase of fine particles in the outflow from the sedimentation tanks, which could not be retained in the filter bed due to high surface charge and the small size of hydrolysis products. When using a coagulant of lower basicity (PAC70), it was much easier to control the dose of coagulant and to adjust it to the changing water quality.
Ferreira, Anna Carolina Galvão; da Silva, José Laerte Rodrigues; Conde, Marcus Barreto; Rabahi, Marcelo Fouad
2013-01-01
OBJECTIVE: To describe the rates of cure, treatment failure, and treatment abandonment obtained with the basic regimen recommended by the Brazilian National Ministry of Health-rifampin, isoniazid, pyrazinamide, and ethambutol for two months, followed by isoniazid and rifampin for four months-involving the use of fixed-dose combination tablets (self-administered treatment), as well as to describe adverse events and their potential impact on treatment outcomes. METHODS: This was a descriptive study based on prospective data obtained from the medical records of tuberculosis patients (≥ 18 years of age) treated with the basic regimen at either of two primary health care facilities in the greater metropolitan area of Goiânia, Brazil. RESULTS: The study sample comprised 40 tuberculosis patients. The rate of cure was 67.5%, the rate of treatment abandonment was 17.5%, and there were no cases of treatment failure. Of the 40 patients in the sample, 19 (47%) reported adverse reactions, which were mild and moderate, respectively, in 87% and 13% of the cases. It was not necessary to alter the regimen or discontinue the treatment in any of the cases evaluated. CONCLUSIONS: The rate of cure obtained with the self-administered, fixed-dose combination tablet form of the new basic regimen was similar to the historical rates of cure obtained with the previous basic regimen. The rate of treatment abandonment in our sample was much higher than that considered appropriate (up to 5%). PMID:23503489
Impact of the Revised 10 CFR 835 on the Neutron Dose Rates at LLNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, R
2009-01-13
In June 2007, 10 CFR 835 [1] was revised to include new radiation weighting factors for neutrons, updated dosimetric models, and dose terms consistent with the newer ICRP recommendations. A significant aspect of the revised 10 CFR 835 is the adoption of the recommendations outlined in ICRP-60 [2]. The recommended new quantities demand a review of much of the basic data used in protection against exposure to sources of ionizing radiation. The International Commission on Radiation Units and Measurements has defined a number of quantities for use in personnel and area monitoring [3,4,5] including the ambient dose equivalent H*(d) tomore » be used for area monitoring and instrument calibrations. These quantities are used in ICRP-60 and ICRP-74. This report deals only with the changes in the ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms neutron dose and neutron dose rate will be used for convenience for ambient neutron dose and ambient neutron dose rate unless otherwise stated. This report provides a qualitative and quantitative estimate of how much the neutron dose rates at LLNL will change with the implementation of the revised 10 CFR 835. Neutron spectra and dose rates from selected locations at the LLNL were measured with a high resolution spectroscopic neutron dose rate system (ROSPEC) as well as with a standard neutron rem meter (a.k.a., a remball). The spectra obtained at these locations compare well with the spectra from the Radiation Calibration Laboratory's (RCL) bare californium source that is currently used to calibrate neutron dose rate instruments. The measurements obtained from the high resolution neutron spectrometer and dose meter ROSPEC and the NRD dose meter compare within the range of {+-}25%. When the new radiation weighting factors are adopted with the implementation of the revised 10 CFR 835, the measured dose rates will increase by up to 22%. The health physicists should consider this increase for any areas that have dose rates near a posting limit, such as near the 100 mrem/hr for a high radiation area, as this increase in measured dose rate may result in some changes to postings and consequent radiological controls.« less
[Basic principles and results of brachytherapy in gynecological oncology].
Kanaev, S V; Turkevich, V G; Baranov, S B; Savel'eva, V V
2014-01-01
The fundamental basics of contact radiation therapy (brachytherapy) for gynecological cancer are presented. During brachytherapy the principles of conformal radiotherapy should be implemented, the aim of which is to sum the maximum possible dose of radiation to the tumor and decrease the dose load in adjacent organs and tissues, which allows reducing the frequency of radiation damage at treatment of primary tumors. It is really feasible only on modern technological level, thanks to precision topometry preparation, optimal computer dosimetrical and radiobiological planning of each session and radiotherapy in general. Successful local and long-term results of the contact radiation therapy for cancer of cervix and endometrium are due to optimal anatomical and topometrical ratio of the tumor localization, radioactive sources, and also physical and radiobiological laws of distribution and effects of ionizing radiation, the dose load accounting rules.
Reddy, Palavai Sripal; Hotha, Kishore Kumar; Sait, Shakil
2013-01-01
A complex, sensitive, and precise high-performance liquid chromatographic method for the profiling of impurities of esomeprazole in low-dose aspirin and esomeprazole capsules has been developed, validated, and used for the determination of impurities in pharmaceutical products. Esomeprazole and its related impurities' development in the presence of aspirin was traditionally difficult due to aspirin's sensitivity to basic conditions and esomeprazole's sensitivity to acidic conditions. When aspirin is under basic, humid, and extreme temperature conditions, it produces salicylic acid and acetic acid moieties. These two byproducts create an acidic environment for the esomeprazole. Due to the volatility and migration phenomenon of the produced acetic acid and salicylic acid from aspirin in the capsule dosage form, esomeprazole's purity, stability, and quantification are affected. The objective of the present research work was to develop a gradient reversed-phase liquid chromatographic method to separate all the degradation products and process-related impurities from the main peak. The impurities were well-separated on a RP8 column (150 mm × 4.6mm, X-terra, RP8, 3.5μm) by the gradient program using a glycine buffer (0.08 M, pH adjusted to 9.0 with 50% NaOH), acetonitrile, and methanol at a flow rate of 1.0 mL min(-1) with detection wavelength at 305 nm and column temperature at 30°C. The developed method was found to be specific, precise, linear, accurate, rugged, and robust. LOQ values for all of the known impurities were below reporting thresholds. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis, and thermal degradation in the presence of aspirin. The developed RP-HPLC method was validated according to the present ICH guidelines for specificity, linearity, accuracy, precision, limit of detection, limit of quantification, ruggedness, and robustness.
42 CFR 82.2 - What are the basics of dose reconstruction?
Code of Federal Regulations, 2014 CFR
2014-10-01
... reconstructions may use monitoring results for groups of workers with comparable activities and relationships to... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES METHODS FOR CONDUCTING DOSE RECONSTRUCTION UNDER THE... found to be complete and adequate, individual worker monitoring data, such as dosimeter readings and...
42 CFR 82.2 - What are the basics of dose reconstruction?
Code of Federal Regulations, 2011 CFR
2011-10-01
... reconstructions may use monitoring results for groups of workers with comparable activities and relationships to... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES METHODS FOR CONDUCTING DOSE RECONSTRUCTION UNDER THE... found to be complete and adequate, individual worker monitoring data, such as dosimeter readings and...
A Critique of Recent Epidemiologic Studies of Cancer Mortality Among Nuclear Workers.
Scott, Bobby R
2018-01-01
Current justification by linear no-threshold (LNT) cancer risk model advocates for its use in low-dose radiation risk assessment is now mainly based on results from flawed and unreliable epidemiologic studies that manufacture small risk increases (ie, phantom risks). Four such studies of nuclear workers, essentially carried out by the same group of epidemiologists, are critiqued in this article. Three of the studies that forcibly applied the LNT model (inappropriate null hypothesis) to cancer mortality data and implicated increased mortality risk from any radiation exposure, no matter how small the dose, are demonstrated to manufacture risk increases for doses up to 100 mSv (or 100 mGy). In a study where risk reduction (hormetic effect/adaptive response) was implicated for nuclear workers, it was assumed by the researchers to relate to a "strong healthy worker effect" with no consideration of the possibility that low radiation doses may help prevent cancer mortality (which is consistent with findings from basic radiobiological research). It was found with basic research that while large radiation doses suppress our multiple natural defenses (barriers) against cancer, these barriers are enhanced by low radiation doses, thereby decreasing cancer risk, essentially rendering the LNT model to be inconsistent with the data.
An Interlaboratory Comparison of Dosimetry for a Multi-institutional Radiobiological
Seed, TM; Xiao, S; Manley, N; Nikolich-Zugich, J; Pugh, J; van den Brink, M; Hirabayashi, Y; Yasutomo, K; Iwama, A; Koyasu, S; Shterev, I; Sempowski, G; Macchiarini, F; Nakachi, K; Kunugi, KC; Hammer, CG; DeWerd, LA
2016-01-01
Purpose An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Methods Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. Results The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤ 5%. Comparable rates of ‘dosimetric compliance’ were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between ‘measured’ and ‘target’ doses, with errors falling largely between 0–20%. Outliers were most notable for OSL-based tests, while multiple tests by ‘non-compliant’ laboratories using orthovoltage x-rays contributed heavily to the wide variation in dosing errors. Conclusions For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized. PMID:26857121
Seed, Thomas M; Xiao, Shiyun; Manley, Nancy; Nikolich-Zugich, Janko; Pugh, Jason; Van den Brink, Marcel; Hirabayashi, Yoko; Yasutomo, Koji; Iwama, Atsushi; Koyasu, Shigeo; Shterev, Ivo; Sempowski, Gregory; Macchiarini, Francesca; Nakachi, Kei; Kunugi, Keith C; Hammer, Clifford G; Dewerd, Lawrence A
2016-01-01
An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤5%. Comparable rates of 'dosimetric compliance' were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between 'measured' and 'target' doses, with errors falling largely between 0 and 20%. Outliers were most notable for OSL-based tests, while multiple tests by 'non-compliant' laboratories using orthovoltage X-rays contributed heavily to the wide variation in dosing errors. For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized.
Laboratory animal studies that are designed to assess the effects of exposure of a test substance during postnatal development are commonly utilized in basic research and to evaluate potential hazard to children for chemical and pharmaceutical regulation. Direct dosing, defined ...
Dose-response-a challenge for allelopathy?
Belz, Regina G; Hurle, Karl; Duke, Stephen O
2005-04-01
The response of an organism to a chemical depends, among other things, on the dose. Nonlinear dose-response relationships occur across a broad range of research fields, and are a well established tool to describe the basic mechanisms of phytotoxicity. The responses of plants to allelochemicals as biosynthesized phytotoxins, relate as well to nonlinearity and, thus, allelopathic effects can be adequately quantified by nonlinear mathematical modeling. The current paper applies the concept of nonlinearity to assorted aspects of allelopathy within several bioassays and reveals their analysis by nonlinear regression models. Procedures for a valid comparison of effective doses between different allelopathic interactions are presented for both, inhibitory and stimulatory effects. The dose-response applications measure and compare the responses produced by pure allelochemicals [scopoletin (7-hydroxy-6-methoxy-2H-1-benzopyran-2-one); DIBOA (2,4-dihydroxy-2H-1,4-benzoxaxin-3(4H)-one); BOA (benzoxazolin-2(3H)-one); MBOA (6-methoxy-benzoxazolin-2(3H)-one)], involved in allelopathy of grain crops, to demonstrate how some general principles of dose responses also relate to allelopathy. Hereupon, dose-response applications with living donor plants demonstrate the validity of these principles for density-dependent phytotoxicity of allelochemicals produced and released by living plants (Avena sativa L., Secale cereale L., Triticum L. spp.), and reveal the use of such experiments for initial considerations about basic principles of allelopathy. Results confirm that nonlinearity applies to allelopathy, and the study of allelopathic effects in dose-response experiments allows for new and challenging insights into allelopathic interactions.
Ishikawa, Tetsuo; Yasumura, Seiji; Ohtsuru, Akira; Sakai, Akira; Akahane, Keiichi; Yonai, Shunsuke; Sakata, Ritsu; Ozasa, Kotaro; Hayashi, Masayuki; Ohira, Tetsuya; Kamiya, Kenji; Abe, Masafumi
2016-06-01
Many studies have been conducted on radiation doses to residents after the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident. Time spent outdoors is an influential factor for external dose estimation. Since little information was available on actual time spent outdoors for residents, different values of average time spent outdoors per day have been used in dose estimation studies on the FDNPP accident. The most conservative value of 24 h was sometimes used, while 2.4 h was adopted for indoor workers in the UNSCEAR 2013 report. Fukushima Medical University has been estimating individual external doses received by residents as a part of the Fukushima Health Management Survey by collecting information on the records of moves and activities (the Basic Survey) after the accident from each resident. In the present study, these records were analyzed to estimate an average time spent outdoors per day. As an example, in Iitate Village, its arithmetic mean was 2.08 h (95% CI: 1.64-2.51) for a total of 170 persons selected from respondents to the Basic Survey. This is a much smaller value than commonly assumed. When 2.08 h is used for the external dose estimation, the dose is about 25% (23-26% when using the above 95% CI) less compared with the dose estimated for the commonly used value of 8 h.
Kato, Takashi; Shiratori, Kyoji; Kobashigawa, Tsuyoshi; Hidaka, Yuji
2006-01-01
A 48-year-old man with systemic lupus erythematosus developed organic brain syndrome. High-dose prednisolone was ineffective, and somnolence without focal signs rapidly developed. Electroencephalogram (EEG) demonstrated a slow basic rhythm (3 Hz), but brain magnetic resonance imaging was normal. Somnolence resolved soon after performing plasma exchange (two sessions). However, memory dysfunction persisted, with EEG demonstrating mild abnormalities (7-8 Hz basic rhythm). Double-filtration plasmapheresis (three sessions) was done, followed by intravenous cyclophosphamide. Immediately after the first plasmapheresis session, memory dysfunction began to improve. After the second dose of cyclophosphamide, intellectual function resolved completely and EEG findings also normalized (basic rhythm of 10 Hz waves). Serial EEG findings precisely reflected the neurological condition and therapeutic efficacy in this patient. In contrast, protein levels in cerebrospinal fluid remained high and did not seem to appropriately reflect the neurological condition in this patient.
Doolittle, N D; Anderson, C P; Bleyer, W A; Cairncross, J G; Cloughesy, T; Eck, S L; Guastadisegni, P; Hall, W A; Muldoon, L L; Patel, S J; Peereboom, D; Siegal, T; Neuwelt, E A
2001-01-01
Therapeutic options for the treatment of malignant brain tumors have been limited, in part, because of the presence of the blood-brain barrier. For this reason, the Sixth Annual Meeting of the Blood-Brain Barrier Disruption Consortium, the focus of which was the "Importance of Dose Intensity in Neuro-Oncology Clinical Trials," was convened in April 2000, at Government Camp, Mount Hood, Oregon. This meeting, which was supported by the National Cancer Institute, the National Institute of Neurological Disorders and Stroke, and the National Institute of Deafness and Other Communication Disorders, brought together clinicians and basic scientists from across the U.S. to discuss the role of dose intensity and enhanced chemotherapy delivery in the treatment of malignant brain tumors and to design multicenter clinical trials. Optimizing chemotherapy delivery to the CNS is crucial, particularly in view of recent progress identifying certain brain tumors as chemosensitive. The discovery that specific constellations of genetic alterations can predict which tumors are chemoresponsive, and can therefore more accurately predict prognosis, has important implications for delivery of intensive, effective chemotherapy regimens with acceptable toxicities. This report summarizes the discussions, future directions, and key questions regarding dose-intensive treatment of primary CNS lymphoma, CNS relapse of systemic non-Hodgkin's lymphoma, anaplastic oligodendroglioma, high-grade glioma, and metastatic cancer of the brain. The promising role of cytoenhancers and chemoprotectants as part of dose-intensive regimens for chemosensitive brain tumors and development of improved gene therapies for malignant gliomas are discussed.
de la Llama-Celis, Natalia; Huarte-Lacunza, Rafael; Gómez-Baraza, Cristina; Cañamares-Orbis, Iciar; Sebastián-Aldeanueva, Manuel; Arrieta-Navarro, Raquel
2012-12-01
The echinocandins have a growing role in the treatment of fungal infections because of their novel mechanism of action. This is reflected in recently published management guidelines, but available in vitro data, animal studies, and clinical studies do not clearly differentiate the three agents in class. Comparative clinical efficacy among agents within the class, pharmacokinetic profiles in special populations, pharmacoeconomics justifications, and place in therapy have been largely unanswered. They share many common properties but marketing strategies of drug manufacturers are engaged in product differentiation. Although exist similarities in the pharmacokinetic (PK) profiles of the echinocandins, limited data have been published regarding their pharmacokinetics in continuous renal replacement therapy (CRRT) patients. The pharmacokinetics of drug removal in critically ill patients receiving CRRT is very complex, with multiple variables affecting clearance. This review outlines the basic principles that determine whether a dose adjustment is required. Two studies with data on PK parameters of micafungin and anidulafungin in CRRT patients have been published and are compared following that basic principles in the review.
Mitomycin C and endoscopic sinus surgery: where are we?
Tabaee, Abtin; Brown, Seth M; Anand, Vijay K
2007-02-01
Mitomycin C has been used successfully in various ophthalmologic and, more recently, otolaryngologic procedures. Its modulation of fibroblast activity allows for decreased scarring and fibrosis. Several recent trials have examined the efficacy of mitomycin C in reducing synechia and stenosis following endoscopic sinus surgery. Basic science studies using fibroblast cell lines have demonstrated a dose-dependent suppression of activity with the use of mitomycin C. This is further supported by animal studies that have shown lower rates of maxillary ostial restenosis following application of mitomycin C. No human trial, however, has demonstrated a statistically significant impact of mitomycin C on the incidence of postoperative synechia or stenosis following sinus surgery. The limitations of the literature are discussed. The antiproliferative properties of mitomycin C may theoretically decrease the incidence of synechia and stenosis following endoscopic sinus surgery. Although this is supported by basic science studies and its successful use in other fields, the clinical evidence to date has not shown the application of mitomycin C to be effective in preventing stenosis after endoscopic sinus surgery. Future prospective studies are required before definitive conclusions can be made.
Commissioning and validation of COMPASS system for VMAT patient specific quality assurance
NASA Astrophysics Data System (ADS)
Pimthong, J.; Kakanaporn, C.; Tuntipumiamorn, L.; Laojunun, P.; Iampongpaiboon, P.
2016-03-01
Pre-treatment patient specific quality assurance (QA) of advanced treatment techniques such as volumetric modulated arc therapy (VMAT) is one of important QA in radiotherapy. The fast and reliable dosimetric device is required. The objective of this study is to commission and validate the performance of COMPASS system for dose verification of VMAT technique. The COMPASS system is composed of an array of ionization detectors (MatriXX) mounted to the gantry using a custom holder and software for the analysis and visualization of QA results. We validated the COMPASS software for basic and advanced clinical application. For the basic clinical study, the simple open field in various field sizes were validated in homogeneous phantom. And the advanced clinical application, the fifteen prostate and fifteen nasopharyngeal cancers VMAT plans were chosen to study. The treatment plans were measured by the MatriXX. The doses and dose-volume histograms (DVHs) reconstructed from the fluence measurements were compared to the TPS calculated plans. And also, the doses and DVHs computed using collapsed cone convolution (CCC) Algorithm were compared with Eclipse TPS calculated plans using Analytical Anisotropic Algorithm (AAA) that according to dose specified in ICRU 83 for PTV.
FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS.
Clairand, I; Ginjaume, M; Vanhavere, F; Carinou, E; Daures, J; Denoziere, M; Silva, E H; Roig, M; Principi, S; Van Rycheghem, L
2016-09-01
In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of the passive eye lens dosemeters currently in use in Europe for occupational monitoring in medical fields. A total of 20 European individual monitoring services from 15 different countries have participated. The dosemeters provided by the participants were all composed of thermoluminescent detectors, of various types and designs. The irradiations were carried out with several photon fields chosen to cover the energy and angle ranges encountered in medical workplace. Participants were asked to report the doses in terms of Hp(3) using their routine protocol. The results provided by each participant were compared with the reference delivered doses. All the results were anonymously analysed. Results are globally satisfactory since, among the 20 participants, 17 were able to provide 90 % of their response in accordance with the ISO 14146 standard requirements. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ishikawa, Tetsuo; Takahashi, Hideto; Yasumura, Seiji; Ohtsuru, Akira; Sakai, Akira; Ohira, Tetsuya; Sakata, Ritsu; Ozasa, Kotaro; Akahane, Keiichi; Yonai, Shunsuke; Kurihara, Osamu; Kamiya, Kenji; Abe, Masafumi
2017-09-25
After the Fukushima Dai-ichi Nuclear Power Plant accident, the Fukushima Health Management Survey (FHMS) was launched. The Basic Survey, a component of FHMS, is a questionnaire used to survey residents across the Fukushima Prefecture about their behaviour in the first 4 months after the accident. The questionnaire findings are used to determine individual external doses by linking behaviour data to a computer programme with daily gamma ray dose rate maps, drawn after the accident. Through 30 June 2015, the response rate was only 27.2% (558 550 population), indicating that the findings might not be generalisable because of poor representativeness of the population. The objective of this study was to clarify if the data from the FHMS Basic Survey were representative of the entire population, by conducting a new survey to compare the external doses between non-respondents and respondents in the previous survey. A total of 5350 subjects were randomly selected from 7 local regions of Fukushima Prefecture. An interview survey was conducted with the non-respondents to the FHMS Basic Survey. A total of 990 responses were obtained from the previous non-responders by interview survey. For the regions Kempoku, Kenchu, Kennan, Aizu, Minami-Aizu, Soso, and Iwaki, differences in mean effective dose (95% confidence interval) in mSv between the non-responders and previous responders were 0.12 (0.01-0.23), -0.09 (-0.21-0.03), -0.06 (-0.18-0.07), 0.05 (-0.04-0.14), 0.01 (-0.01-0.02), 0.09 (0.01-0.17), 0.09 (0.00-0.17), respectively. The differences fall neither within the interval (-∞, -0.25) nor within the interval (0.25, ∞). These findings imply that mean effective doses between the previous and new respondents were not different, with a significantly indifferent region of 0.25 mSv according to equivalence tests. The present study indicates that the dose distribution obtained from about one-quarter of Fukushima residents represents the dose distribution for the entire Fukushima Prefecture.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nimmagadda, M.; Yu, C.
1993-04-01
Residual radioactive material guidelines for strontium-90 and cesium-137 were derived for the Laboratory for Energy-Related Health Research (LEHR) site in Davis, California. The guideline derivation was based on a dose limit of 100 mrem/yr. The US Department of Energy (DOE) residual radioactive material guideline computer code, RESRAD, was used in this evaluation; this code implements the methodology described in the DOE manual for implementing residual radioactive material guidelines. Three potential site utilization scenarios were considered with the assumption that, for a period of 1,000 years following remedial action, the site will be utilized without radiological restrictions. The defined scenarios varymore » with regard to use of the site, time spent at the site, and sources of food consumed. The results of the evaluation indicate that the basic dose limit of 100 mrem/yr will not be exceeded within 1,000 years for either strontium-90 or cesium-137, provided that the soil concentrations of these radionuclides at the LEHR site do not exceed the following levels: 71,000 pCi/g for strontium-90 and 91 pCi/g for cesium-137 for Scenario A (researcher: the expected scenario); 160,000 pCi/g for strontium-90 and 220 pCi/g for cesium-137 for Scenario B (recreationist: a plausible scenario); and 37 pCi/g for strontium-90 and 32 pCi/g for cesium-137 for Scenario C (resident farmer ingesting food produced in the contaminated area: a plausible scenario). The derived guidelines are single-radionuclide guidelines and are linearly proportional to the dose limit used in the calculations. In setting the actual strontium-90 and cesium-137 guidelines for the LEHR site, DOE will apply the as low as reasonably achievable (ALARA) policy to the decision-making process, along with other factors such as whether a particular scenario is reasonable and appropriate.« less
Regulation of NORM by the US Department of Energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duvall, K.C.; Peterson, H.T. Jr.
1997-02-01
The authors discuss the radiation protection standards of the DOE for protection of the general public, which at present are primarily outlined in Order DOE 5400.5 and 10 CFR Part 834. The requirements include: basic dose limits for protection of the general public; radionuclide concentration guidelines for air and water; and surface contamination criteria for controlling the release of soil and equipment for restricted or unrestricted use. A major component of these orders is the concept of keeping radiation exposures as low as is reasonably achievable (ALARA), and the authors explain how this is applied to the implementation of themore » orders. Sections of the orders address radiation protection issues regarding natural radioactivity exposures.« less
NASA Astrophysics Data System (ADS)
Tanaka, Hiroshi; Hashimura, Shinji; Hiroo, Yasuaki
We present a program to learn ability to solve problems on engineering. This program is called “Experiments in creative engineering” in the department of mechanical engineering in Kurume National College of Technology advanced engineering school. In the program, students have to determine own theme and manufacture experimental devices or some machines by themselves. The students must also perform experiments to valid the function and performance of their devices by themselves. The restriction of the theme is to manufacture a device which function dose not basically exist in the world with limited cost (up to 20,000Yen) . As the results of questionnaire of students, the program would be very effective to the creative education for the students.
Space radiation risk limits and Earth-Moon-Mars environmental models
NASA Astrophysics Data System (ADS)
Cucinotta, Francis A.; Hu, Shaowen; Schwadron, Nathan A.; Kozarev, K.; Townsend, Lawrence W.; Kim, Myung-Hee Y.
2010-12-01
We review NASA's short-term and career radiation limits for astronauts and methods for their application to future exploration missions outside of low Earth orbit. Career limits are intended to restrict late occurring health effects and include a 3% risk of exposure-induced death from cancer and new limits for central nervous system and heart disease risks. Short-term dose limits are used to prevent in-flight radiation sickness or death through restriction of the doses to the blood forming organs and to prevent clinically significant cataracts or skin damage through lens and skin dose limits, respectively. Large uncertainties exist in estimating the health risks of space radiation, chiefly the understanding of the radiobiology of heavy ions and dose rate and dose protraction effects, and the limitations in human epidemiology data. To protect against these uncertainties NASA estimates the 95% confidence in the cancer risk projection intervals as part of astronaut flight readiness assessments and mission design. Accurate organ dose and particle spectra models are needed to ensure astronauts stay below radiation limits and to support the goal of narrowing the uncertainties in risk projections. Methodologies for evaluation of space environments, radiation quality, and organ doses to evaluate limits are discussed, and current projections for lunar and Mars missions are described.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-30
... Radiological Protection; Recommendations on the Annual Dose Limit to the Lens of the Eye AGENCY: Nuclear... Protection (ICRP) recommendations for the limitation of annual dose to the lens of the eye. This significant... might be lower than previously considered. For the lens of the eye, the threshold in absorbed dose for...
Pharmacokinetics of drugs in pregnancy.
Feghali, Maisa; Venkataramanan, Raman; Caritis, Steve
2015-11-01
Pregnancy is a complex state where changes in maternal physiology have evolved to favor the development and growth of the placenta and the fetus. These adaptations may affect preexisting disease or result in pregnancy-specific disorders. Similarly, variations in physiology may alter the pharmacokinetics or pharmacodynamics that determines drug dosing and effect. It follows that detailed pharmacologic information is required to adjust therapeutic treatment strategies during pregnancy. Understanding both pregnancy physiology and the gestation-specific pharmacology of different agents is necessary to achieve effective treatment and limit maternal and fetal risk. Unfortunately, most drug studies have excluded pregnant women based on often-mistaken concerns regarding fetal risk. Furthermore, over two-thirds of women receive prescription drugs while pregnant, with treatment and dosing strategies based on data from healthy male volunteers and non-pregnant women, and with little adjustment for the complex physiology of pregnancy and its unique disease states. This review will describe basic concepts in pharmacokinetics and their clinical relevance and highlight the variations in pregnancy that may impact the pharmacokinetic properties of medications. Copyright © 2015 Elsevier Inc. All rights reserved.
Brocks, Dion R
2015-07-01
Pharmacokinetics can be a challenging topic to teach due to the complex relationships inherent between physiological parameters, mathematical descriptors and equations, and their combined impact on shaping the blood fluid concentration vs. time curves of drugs. A computer program was developed within Microsoft Excel for Windows, designed to assist in the instruction of basic pharmacokinetics within an entry-to-practice pharmacy class environment. The program is composed of a series of spreadsheets (modules) linked by Visual Basic for Applications, intended to illustrate the relationships between pharmacokinetic and in some cases physiological parameters, doses and dose rates and the drug blood fluid concentration vs. time curves. Each module is accompanied by a simulation user's guide, prompting the user to change specific independent parameters and then observe the impact of the change(s) on the drug concentration vs. time curve and on other dependent parameters. "Slider" (or "scroll") bars can be selected to readily see the effects of repeated changes on the dependencies. Topics covered include one compartment single dose administration (iv bolus, oral, short infusion), intravenous infusion, repeated doses, renal and hepatic clearance, nonlinear elimination, two compartment model, plasma protein binding and the relationship between pharmacokinetics and drug effect. The program has been used in various forms in the classroom over a number of years, with positive ratings generally being received from students for its use in the classroom. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Ushakov, I B; Grigoriev, Yu G; Shafirkin, A V; Shurshakov, V A
2016-01-01
Review of the data of experimental radiobiology and epidemiological follow-up of large groups of people subjected to radiation exposures on Earth has been undertaken to substantiate dose limits for critical organs of cosmonauts in order to ensure good performance and vitality while on long-duration orbital missions. The career dose limits for cosmonauts and astronauts established earlier in the USSR and USA amounted to nothing more but banning the risk of cancer death increase to 3%. To apply more rigorous criteria of delayed radiation risks, the Russian limits for cosmonauts were revised to substantiate a 4-fold reduction of the average tissue equivalent dose maximum to 1 Sv. The total of cancer and non-cancer radiation risks over lifetime and probable reduction of mean life expectancy (MLE) were calculated using the model of radiation-induced mortality for mammals and taken as the main damage to health. The established dose limit is equal to the career dose for nuclear industry personnel set forth by Russian standard document NRB 99/2009. For better agreement of admissible threshold doses to critical human organs (bone marrow, lens and skin) in the revised radiation limits for long-duration space missions and radiation safety limits on Earth, reduction of dose limits for the critical organs were substantiated additionally; these limits comply with those for planned over-exposure on Earth in document NRB 99/2009.
Using the Composing Process and Positive Reinforcement to Teach College Basic Students to Write.
ERIC Educational Resources Information Center
Milligan, Janice
Following a literature review on the subjects of the decline in student writing abilities and increased student writing apprehension, this paper offers teachers information on a basic writing program that reduces writing anxiety and improves writing skills through large doses of positive reinforcement. The second section of the paper discusses the…
Nanotechnology applications in hematological malignancies (Review).
Samir, Ahmed; Elgamal, Basma M; Gabr, Hala; Sabaawy, Hatem E
2015-09-01
A major limitation to current cancer therapies is the development of therapy-related side-effects and dose limiting complications. Moreover, a better understanding of the biology of cancer cells and the mechanisms of resistance to therapy is rapidly developing. The translation of advanced knowledge and discoveries achieved at the molecular level must be supported by advanced diagnostic, therapeutic and delivery technologies to translate these discoveries into useful tools that are essential in achieving progress in the war against cancer. Nanotechnology can play an essential role in this aspect providing a transforming technology that can translate the basic and clinical findings into novel diagnostic, therapeutic and preventive tools useful in different types of cancer. Hematological malignancies represent a specific class of cancer, which attracts special attention in the applications of nanotechnology for cancer diagnosis and treatment. The aim of the present review is to elucidate the emerging applications of nanotechnology in cancer management and describe the potentials of nanotechnology in changing the key fundamental aspects of hematological malignancy diagnosis, treatment and follow-up.
Nanotechnology applications in hematological malignancies (Review)
SAMIR, AHMED; ELGAMAL, BASMA M; GABR, HALA; SABAAWY, HATEM E
2015-01-01
A major limitation to current cancer therapies is the development of therapy-related side-effects and dose limiting complications. Moreover, a better understanding of the biology of cancer cells and the mechanisms of resistance to therapy is rapidly developing. The translation of advanced knowledge and discoveries achieved at the molecular level must be supported by advanced diagnostic, therapeutic and delivery technologies to translate these discoveries into useful tools that are essential in achieving progress in the war against cancer. Nanotechnology can play an essential role in this aspect providing a transforming technology that can translate the basic and clinical findings into novel diagnostic, therapeutic and preventive tools useful in different types of cancer. Hematological malignancies represent a specific class of cancer, which attracts special attention in the applications of nanotechnology for cancer diagnosis and treatment. The aim of the present review is to elucidate the emerging applications of nanotechnology in cancer management and describe the potentials of nanotechnology in changing the key fundamental aspects of hematological malignancy diagnosis, treatment and follow-up. PMID:26134389
Dose-Response—A Challenge for Allelopathy?
Belz, Regina G.; Hurle, Karl; Duke, Stephen O.
2005-01-01
The response of an organism to a chemical depends, among other things, on the dose. Nonlinear dose-response relationships occur across a broad range of research fields, and are a well established tool to describe the basic mechanisms of phytotoxicity. The responses of plants to allelochemicals as biosynthesized phytotoxins, relate as well to nonlinearity and, thus, allelopathic effects can be adequately quantified by nonlinear mathematical modeling. The current paper applies the concept of nonlinearity to assorted aspects of allelopathy within several bioassays and reveals their analysis by nonlinear regression models. Procedures for a valid comparison of effective doses between different allelopathic interactions are presented for both, inhibitory and stimulatory effects. The dose-response applications measure and compare the responses produced by pure allelochemicals [scopoletin (7-hydroxy-6-methoxy-2H-1-benzopyran-2-one); DIBOA (2,4-dihydroxy-2H-1,4-benzoxaxin-3(4H)-one); BOA (benzoxazolin-2(3H)-one); MBOA (6-methoxy-benzoxazolin-2(3H)-one)], involved in allelopathy of grain crops, to demonstrate how some general principles of dose responses also relate to allelopathy. Hereupon, dose-response applications with living donor plants demonstrate the validity of these principles for density-dependent phytotoxicity of allelochemicals produced and released by living plants (Avena sativa L., Secale cereale L., Triticum L. spp.), and reveal the use of such experiments for initial considerations about basic principles of allelopathy. Results confirm that nonlinearity applies to allelopathy, and the study of allelopathic effects in dose-response experiments allows for new and challenging insights into allelopathic interactions. PMID:19330161
Kundu, Amartya; Fitzgibbons, Timothy P
2015-09-24
Sinus bradycardia has been reported after administration of pulse dose steroids, although most cases have occurred in children and are asymptomatic. We report a case of acute symptomatic sinus bradycardia due to pulse dose steroids in a woman with multiple sclerosis. Interestingly, this patient also suffered from inappropriate sinus tachycardia due to autonomic involvement of multiple sclerosis. A 48-year-old Caucasian woman with multiple sclerosis and chronic palpitations due to inappropriate sinus tachycardia was prescribed a 5-day course of intravenous methylprednisolone for treatment of an acute flare. Immediately following the fourth dose of intravenous methylprednisolone, she developed dyspnea, chest heaviness, and lightheadedness. She was referred to the emergency department where an electrocardiogram showed marked sinus bradycardia (40 beats per minute). Initial laboratory test results, including a complete blood count, basic metabolic profile and cardiac biomarkers, were normal. She was admitted for observation on telemetry monitoring. Her heart rate gradually increased and her symptoms resolved. Her outpatient dose of atenolol, taken for symptomatic inappropriate sinus tachycardia, was resumed. Our patient's acute symptoms were attributed to symptomatic sinus bradycardia due to pulse dose steroid treatment. Although several theories have been suggested to explain this phenomenon, the exact mechanism still remains unknown. It does not warrant any specific treatment, as it is a self-limiting side effect that resolves after discontinuing steroid infusion. Young patients who are free of any active cardiac conditions can safely be administered pulse dose steroids without monitoring. However, older patients with active cardiac conditions should have heart rate and blood pressure monitoring during infusion. Our patient also suffered from inappropriate sinus tachycardia, a manifestation of autonomic involvement of multiple sclerosis that has not been previously described. This case has implications for the pathogenesis and treatment of dysautonomia in patients with multiple sclerosis.
Miksys, N; Xu, C; Beaulieu, L; Thomson, R M
2015-08-07
This work investigates and compares CT image metallic artifact reduction (MAR) methods and tissue assignment schemes (TAS) for the development of virtual patient models for permanent implant brachytherapy Monte Carlo (MC) dose calculations. Four MAR techniques are investigated to mitigate seed artifacts from post-implant CT images of a homogeneous phantom and eight prostate patients: a raw sinogram approach using the original CT scanner data and three methods (simple threshold replacement (STR), 3D median filter, and virtual sinogram) requiring only the reconstructed CT image. Virtual patient models are developed using six TAS ranging from the AAPM-ESTRO-ABG TG-186 basic approach of assigning uniform density tissues (resulting in a model not dependent on MAR) to more complex models assigning prostate, calcification, and mixtures of prostate and calcification using CT-derived densities. The EGSnrc user-code BrachyDose is employed to calculate dose distributions. All four MAR methods eliminate bright seed spot artifacts, and the image-based methods provide comparable mitigation of artifacts compared with the raw sinogram approach. However, each MAR technique has limitations: STR is unable to mitigate low CT number artifacts, the median filter blurs the image which challenges the preservation of tissue heterogeneities, and both sinogram approaches introduce new streaks. Large local dose differences are generally due to differences in voxel tissue-type rather than mass density. The largest differences in target dose metrics (D90, V100, V150), over 50% lower compared to the other models, are when uncorrected CT images are used with TAS that consider calcifications. Metrics found using models which include calcifications are generally a few percent lower than prostate-only models. Generally, metrics from any MAR method and any TAS which considers calcifications agree within 6%. Overall, the studied MAR methods and TAS show promise for further retrospective MC dose calculation studies for various permanent implant brachytherapy treatments.
14 CFR Appendix A to Part 121 - First Aid Kits and Emergency Medical Kits
Code of Federal Regulations, 2013 CFR
2013-01-01
..., 50cc 1 Epinephrine 1:1000, single dose ampule or equivalent) 2 Diphenhydramine HC1 injection, single dose ampule or equivalent 2 Nitroglycerin tablets 10 Basic instructions for use of the drugs in the kit 1 protective nonpermeable gloves or equivalent 1 pair 2. As of April 12, 2004, at least one approved...
14 CFR Appendix A to Part 121 - First Aid Kits and Emergency Medical Kits
Code of Federal Regulations, 2010 CFR
2010-01-01
..., 50cc 1 Epinephrine 1:1000, single dose ampule or equivalent) 2 Diphenhydramine HC1 injection, single dose ampule or equivalent 2 Nitroglycerin tablets 10 Basic instructions for use of the drugs in the kit 1 protective nonpermeable gloves or equivalent 1 pair 2. As of April 12, 2004, at least one approved...
14 CFR Appendix A to Part 121 - First Aid Kits and Emergency Medical Kits
Code of Federal Regulations, 2014 CFR
2014-01-01
..., 50cc 1 Epinephrine 1:1000, single dose ampule or equivalent) 2 Diphenhydramine HC1 injection, single dose ampule or equivalent 2 Nitroglycerin tablets 10 Basic instructions for use of the drugs in the kit 1 protective nonpermeable gloves or equivalent 1 pair 2. As of April 12, 2004, at least one approved...
14 CFR Appendix A to Part 121 - First Aid Kits and Emergency Medical Kits
Code of Federal Regulations, 2011 CFR
2011-01-01
..., 50cc 1 Epinephrine 1:1000, single dose ampule or equivalent) 2 Diphenhydramine HC1 injection, single dose ampule or equivalent 2 Nitroglycerin tablets 10 Basic instructions for use of the drugs in the kit 1 protective nonpermeable gloves or equivalent 1 pair 2. As of April 12, 2004, at least one approved...
14 CFR Appendix A to Part 121 - First Aid Kits and Emergency Medical Kits
Code of Federal Regulations, 2012 CFR
2012-01-01
..., 50cc 1 Epinephrine 1:1000, single dose ampule or equivalent) 2 Diphenhydramine HC1 injection, single dose ampule or equivalent 2 Nitroglycerin tablets 10 Basic instructions for use of the drugs in the kit 1 protective nonpermeable gloves or equivalent 1 pair 2. As of April 12, 2004, at least one approved...
O'Connor, U; Gallagher, A; Malone, L; O'Reilly, G
2013-02-01
Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that combines the use of X-ray fluoroscopy and endoscopy for examination of the bile duct. Published data on ERCP doses are limited, including staff eye dose from ERCP. Occupational eye doses are of particular interest now as the International Commission on Radiological Protection (ICRP) has recommended a reduction in the dose limit to the lens of the eye. The aim of this study was to measure occupational eye doses obtained from ERCP procedures. A new eye lens dosemeter (EYE-D(™), Radcard, Krakow, Poland) was used to measure the ERCP eye dose, H(p)(3), at two endoscopy departments in Ireland. A review of radiation protection practice at the two facilities was also carried out. The mean equivalent dose to the lens of the eye of a gastroenterologist is 0.01 mSv per ERCP procedure with an undercouch X-ray tube and 0.09 mSv per ERCP procedure with an overcouch X-ray tube. Staff eye dose normalised to patient kerma area product is also presented. Staff eye doses in ERCP have the potential to exceed the revised ICRP limit of 20 mSv per annum when an overcouch X-ray tube is used. The EYE-D dosemeter was found to be a convenient method for measuring lens dose. Eye doses in areas outside of radiology departments should be kept under review, particularly in light of the new ICRP eye dose limit. Occupational eye lens doses from ERCP procedures have been established using a new commercially available dedicated H(p)(3) dosemeter.
10 CFR 20.1302 - Compliance with dose limits for individual members of the public.
Code of Federal Regulations, 2013 CFR
2013-01-01
... public. 20.1302 Section 20.1302 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiation Dose Limits for Individual Members of the Public § 20.1302 Compliance with dose limits..., surveys of radiation levels in unrestricted and controlled areas and radioactive materials in effluents...
10 CFR 20.1302 - Compliance with dose limits for individual members of the public.
Code of Federal Regulations, 2014 CFR
2014-01-01
... public. 20.1302 Section 20.1302 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiation Dose Limits for Individual Members of the Public § 20.1302 Compliance with dose limits..., surveys of radiation levels in unrestricted and controlled areas and radioactive materials in effluents...
10 CFR 20.1302 - Compliance with dose limits for individual members of the public.
Code of Federal Regulations, 2012 CFR
2012-01-01
... public. 20.1302 Section 20.1302 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiation Dose Limits for Individual Members of the Public § 20.1302 Compliance with dose limits..., surveys of radiation levels in unrestricted and controlled areas and radioactive materials in effluents...
10 CFR 20.1302 - Compliance with dose limits for individual members of the public.
Code of Federal Regulations, 2011 CFR
2011-01-01
... public. 20.1302 Section 20.1302 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiation Dose Limits for Individual Members of the Public § 20.1302 Compliance with dose limits..., surveys of radiation levels in unrestricted and controlled areas and radioactive materials in effluents...
10 CFR 20.1302 - Compliance with dose limits for individual members of the public.
Code of Federal Regulations, 2010 CFR
2010-01-01
... public. 20.1302 Section 20.1302 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiation Dose Limits for Individual Members of the Public § 20.1302 Compliance with dose limits..., surveys of radiation levels in unrestricted and controlled areas and radioactive materials in effluents...
Vegt, Erik; Wetzels, Jack F M; Russel, Frans G M; Masereeuw, Rosalinde; Boerman, Otto C; van Eerd, Juliette E; Corstens, Frans H M; Oyen, Wim J G
2006-03-01
Peptide receptor-mediated radiotherapy of neuroendocrine and other somatostatin receptor-positive tumors with radiolabeled somatostatin analogs has been applied in several experimental settings. The kidneys are the organs responsible for dose-limiting toxicity attributable to the retention of radiolabeled octreotide in the renal cortex, leading to a relatively high radiation dose that may result in irreversible loss of kidney function. The administration of basic amino acids reduces renal uptake but does have significant side effects. We observed that gelatin-based plasma expanders induced tubular low-molecular-weight proteinuria in healthy volunteers, suggesting that components in these solutions can interfere with the tubular reabsorption of proteins and peptides. Here, we studied the effects of infusion of low doses of the plasma expander succinylated gelatin (GELO) on the renal uptake of 111In-labeled octreotide (111In-OCT). Five healthy volunteers were given 111In-OCT, first in combination with normal saline and 2 wk later in combination with GELO. Scintigraphic images of the kidneys as well as blood and urine samples were analyzed. To exclude a nonspecific hemodynamic effect of the plasma expander, the procedure was repeated with 5 other volunteers who received the carbohydrate-based plasma expander hydroxyethyl starch (HES). Low doses of GELO were able to effectively reduce the kidney retention of 111In-OCT. The renal radiation dose was significantly reduced by 45% +/- 10% (mean +/- SD) (P = 0.006), whereas HES showed no significant effect (0% +/- 12%). The infusion of GELO did not cause any side effects. GELO effectively reduces the renal uptake of 111In-OCT. In contrast to currently used mixtures of amino acids, GELO does not cause any side effects.
Analysis of Exposure-Dose Variation of Inhaled Particles in Adult Subjects.
Although internal dose is a key factor for determining the health risk of inhaled pollutant particles, available dose information is largely limited to young healthy adults under a few typical exposure conditions. Extrapolation of the limited dose information to different populat...
Ferreira, Anna Carolina Galvão; Silva Júnior, José Laerte Rodrigues da; Conde, Marcus Barreto; Rabahi, Marcelo Fouad
2013-01-01
To describe the rates of cure, treatment failure, and treatment abandonment obtained with the basic regimen recommended by the Brazilian National Ministry of Health (rifampin, isoniazid, pyrazinamide, and ethambutol for two months, followed by isoniazid and rifampin for four months) involving the use of fixed-dose combination tablets (self-administered treatment), as well as to describe adverse events and their potential impact on treatment outcomes. This was a descriptive study based on prospective data obtained from the medical records of tuberculosis patients (> 18 years of age) treated with the basic regimen at either of two primary health care facilities in the greater metropolitan area of Goiânia, Brazil. The study sample comprised 40 tuberculosis patients. The rate of cure was 67.5%, the rate of treatment abandonment was 17.5%, and there were no cases of treatment failure. Of the 40 patients in the sample, 19 (47%) reported adverse reactions, which were mild and moderate, respectively, in 87% and 13% of the cases. It was not necessary to alter the regimen or discontinue the treatment in any of the cases evaluated. The rate of cure obtained with the self-administered, fixed-dose combination tablet form of the new basic regimen was similar to the historical rates of cure obtained with the previous regimen. The rate of treatment abandonment in our sample was much higher than that considered appropriate (up to 5%).
Develop real-time dosimetry concepts and instrumentation for long term missions
NASA Technical Reports Server (NTRS)
Braby, L. A.
1982-01-01
The development of a rugged portable instrument to evaluate dose and dose equivalent is described. A tissue-equivalent proportional counter simulating a 2 micrometer spherical tissue volume was operated satisfactorily for over a year. The basic elements of the electronic system were designed and tested. And finally, the most suitable mathematical technique for evaluating dose equivalent with a portable instrument was selected. Design and fabrication of a portable prototype, based on the previously tested circuits, is underway.
Radioimmunoassays and 2-site immunoradiometric "sandwich" assays: basic principles.
Rodbard, D
1988-10-01
The "sandwich" or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.
The Educated Guess: Determining Drug Doses in Exotic Animals Using Evidence-Based Medicine.
Visser, Marike; Oster, Seth C
2018-05-01
Lack of species-specific pharmacokinetic and pharmacodynamic data is a challenge for pharmaceutical and dose selection. If available, dose extrapolation can be accomplished via basic equations. If unavailable, several methods have been described. Linear scaling uses an established milligrams per kilograms dose based on weight. This does not allow for differences in species drug metabolism, sometimes resulting in toxicity. Allometric scaling correlates body weight and metabolic rate but fails for drugs with significant hepatic metabolism and cannot be extrapolated to avians or reptiles. Evidence-based veterinary medicine for dose design based on species similarity is discussed, considering physiologic differences between classes. Copyright © 2018 Elsevier Inc. All rights reserved.
Napier, Bruce
2012-03-01
A brief description is provided of the basic concepts related to 'internal dose' and how it differs from doses that result from radioactive materials and direct radiation outside of the body. The principles of radiation dose reconstruction, as applied to both internal and external doses, are discussed on the basis of a recent publication prepared by the US National Council on Radiation Protection and Measurements. Finally, ideas are introduced related to residual radioactive contamination in the environment that has resulted from the releases from damaged reactors and also to the management of wastes that may be generated in both regional cleanup and decommissioning of the Fukushima nuclear power plant.
Hamada, Nobuyuki; Fujimichi, Yuki
2014-01-01
Radiation exposure causes cancer and non-cancer health effects, each of which differs greatly in the shape of the dose–response curve, latency, persistency, recurrence, curability, fatality and impact on quality of life. In recent decades, for dose limitation purposes, the International Commission on Radiological Protection has divided such diverse effects into tissue reactions (formerly termed non-stochastic and deterministic effects) and stochastic effects. On the one hand, effective dose limits aim to reduce the risks of stochastic effects (cancer/heritable effects) and are based on the detriment-adjusted nominal risk coefficients, assuming a linear-non-threshold dose response and a dose and dose rate effectiveness factor of 2. On the other hand, equivalent dose limits aim to avoid tissue reactions (vision-impairing cataracts and cosmetically unacceptable non-cancer skin changes) and are based on a threshold dose. However, the boundary between these two categories is becoming vague. Thus, we review the changes in radiation effect classification, dose limitation concepts, and the definition of detriment and threshold. Then, the current situation is overviewed focusing on (i) stochastic effects with a threshold, (ii) tissue reactions without a threshold, (iii) target organs/tissues for circulatory disease, (iv) dose levels for limitation of cancer risks vs prevention of non-life-threatening tissue reactions vs prevention of life-threatening tissue reactions, (v) mortality or incidence of thyroid cancer, and (vi) the detriment for tissue reactions. For future discussion, one approach is suggested that classifies radiation effects according to whether effects are life threatening, and radiobiological research needs are also briefly discussed. PMID:24794798
Modeling adverse event counts in phase I clinical trials of a cytotoxic agent.
Muenz, Daniel G; Braun, Thomas M; Taylor, Jeremy Mg
2018-05-01
Background/Aims The goal of phase I clinical trials for cytotoxic agents is to find the maximum dose with an acceptable risk of severe toxicity. The most common designs for these dose-finding trials use a binary outcome indicating whether a patient had a dose-limiting toxicity. However, a patient may experience multiple toxicities, with each toxicity assigned an ordinal severity score. The binary response is then obtained by dichotomizing a patient's richer set of data. We contribute to the growing literature on new models to exploit this richer toxicity data, with the goal of improving the efficiency in estimating the maximum tolerated dose. Methods We develop three new, related models that make use of the total number of dose-limiting and low-level toxicities a patient experiences. We use these models to estimate the probability of having at least one dose-limiting toxicity as a function of dose. In a simulation study, we evaluate how often our models select the true maximum tolerated dose, and we compare our models with the continual reassessment method, which uses binary data. Results Across a variety of simulation settings, we find that our models compare well against the continual reassessment method in terms of selecting the true optimal dose. In particular, one of our models which uses dose-limiting and low-level toxicity counts beats or ties the other models, including the continual reassessment method, in all scenarios except the one in which the true optimal dose is the highest dose available. We also find that our models, when not selecting the true optimal dose, tend to err by picking lower, safer doses, while the continual reassessment method errs more toward toxic doses. Conclusion Using dose-limiting and low-level toxicity counts, which are easily obtained from data already routinely collected, is a promising way to improve the efficiency in finding the true maximum tolerated dose in phase I trials.
Hosein, Z Z; Gilbert, J J; Strejan, G H
1984-12-01
Hartley guinea pig central nervous system (CNS) myelin has been purified and fractionated into its protein and lipid components. Experimental allergic encephalomyelitis (EAE) was induced in juvenile strain 13 guinea pigs with both lyophilized and fresh 'wet' myelin. However, a larger dose of lyophilized myelin was required to induce chronic EAE. Total myelin lipids, galactocerebrosides, gangliosides, phospholipids or proteolipids were combined with a non-encephalitogenic dose of myelin basic protein (MBP) and injected in juvenile Hartley guinea pigs. No clinical or histological manifestations of disease were observed. Parameters of immune functions indicated that the total myelin lipids augmented cell-mediated immune responses as measured by in vitro lymphocyte transformation and by a significant decrease in the percentage of peripheral early T cells. Only the proteolipids elicited delayed hypersensitivity reactions. Animals that received the phospholipid-MBP combination showed no changes when compared to animals injected with MBP alone. The results suggest that although the myelin lipids did not act synergistically with a non-encephalitogenic dose of MBP to induce EAE, they induced immunological changes and potentiated the immune response to MBP.
1998-01-01
(79) Waste, by definition, has no benefit. It should be viewed as one aspect of the beneficial practice that gave rise to it. Furthermore, radioactive waste management should be placed in the context of the management of society's waste in general. (80) A major issue in evaluating the acceptability of a disposal system for long-lived solid radioactive waste is that doses or risks may arise from exposures in the distant future. There is uncertainty surrounding any estimate of these doses or risks due to lack of knowledge about future conditions. Such exposures are treated as potential exposures as their magnitude depends on future processes and conditions that have probabilities associated with them. (81) Nevertheless, the Commission recognises a basic principle that individuals and populations in the future should be afforded at least the same level of protection from the action of disposing of radioactive waste today as is the current generation. This implies use of the current quantitative dose and risk criteria derived from considering associated health detriment. Therefore, protection of future generations should be achieved by applying these dose or risk criteria to the estimated future doses or risks in appropriately defined critical groups. These estimates should not be regarded as measures of health detriment beyond times of around several hundreds of years into the future. In the case of these longer time periods, they represent indicators of the protection afforded by the disposal system. (82 Constrained optimisation is the central approach to evaluating the radiological acceptability of a waste disposal system; dose or risk constraints are used rather than dose or risk limits. By this transition from limitation to optimisation, the needs of practical application of the radiological protection system to the disposal of long-lived solid waste disposal are met: determination of acceptability now for exposures that may occur in the distant future. Optimisation should be applied in an iterative manner during the disposal system development process and should particularly cover both site selection and repository design. (83) Two broad categories of exposure situations should be considered: natural processes and human intrusion. The latter only refers to intrusion that is inadvertent. The radiological implications of deliberate intrusion into a repository are the responsibility of the intruder. Assessed doses or risks arising from natural processes should be compared with a dose constraint of 0.3 mSv per year or its risk equivalent of around 10(-5) per year. With regard to human intrusion, the consequences from one or more plausible stylized scenarios should be considered in order to evaluate the resilience of the repository to such events. (84) The Commission considers that in circumstances where human intrusion could lead to doses to those living around the site sufficiently high that intervention on current criteria would almost always be justified, reasonable efforts should be made at the repository development stage to reduce the probability of human intrusion or to limit its consequences. In this respect, the Commission has previously advised that an existing annual dose of around 10 mSv per year may be used as a generic reference level below which intervention is not likely to be justifiable. Conversely, an existing annual dose of around 100 mSv per year may be used as a generic reference level above which intervention should be considered almost always justifiable. Similar considerations apply in situations where the thresholds for deterministic effects in relevant organs are exceeded. (85) Compliance with the constraints can be assessed by utilising either an aggregated risk-oriented approach, with a risk constraint, or a disaggregated dose/probability approach, with a dose constraint, or a combination of both. A similar level of protection can be achieved by any of these approaches; however, more information may
Synergistic Effect of Freezing and Irradiation on Bonito Fish ( Sarda sarda Bloch, 1793).
Altan, Can Okan; Turan, Hülya
2016-12-01
In this study, bonito fish ( Sarda sarda Bloch, 1793) were irradiated at 3 or 5 kGy, packaged, frozen, and stored at -20 ± 2°C for 12 months. During storage, the microbiological, physical, and chemical changes of the fish flesh were then assessed. Increasing the irradiation dose to 5 kGy provided greater inhibition of mesophilic and psychotropic aerobic bacteria (P < 0.05). Because fewer bacteria were detected in irradiated (3 and 5 kGy) as compared with unirradiated control fish suggests that freezing and irradiation yielded better results when combined. Irradiation at 3 and 5 kGy also positively impacted water activity, total volatile basic nitrogen, thiobarbituric acid-reactive substances, trimethylamine, and odor compared with the control group. However, a significant difference was not seen between the 3- and 5-kGy groups in terms of water activity, total volatile basic nitrogen, thiobarbituric acid-reactive substances, trimethylamine, and odor results (P > 0.05). Based on these findings, fish irradiated at 3 and 5 kGy remained within consumable limits during 12 months of frozen storage, while the control group was unacceptable after 9 months.
Walsh, C; Gallagher, A; Dowling, A; Guiney, M; Ryan, J M; McEniff, N; O'Reilly, G
2015-01-01
Objective: In 2011, the International Commission on Radiological Protection (ICRP) recommended a substantial reduction in the equivalent dose limit for the lens of the eye, in line with a reduced threshold of absorbed dose for radiation-induced cataracts. This is of particular relevance in interventional radiology (IR) where it is well established that staff doses can be significant, however, there is a lack of data on IR eye doses in terms of Hp(3). Hp(3) is the personal dose equivalent at a depth of 3 mm in soft tissue and is used for measuring lens dose. We aimed to obtain a reliable estimate of eye dose to IR operators. Methods: Lens doses were measured for four interventional radiologists over a 3-month period using dosemeters specifically designed to measure Hp(3). Results: Based on their typical workloads, two of the four interventional radiologists would exceed the new ICRP dose limit with annual estimated doses of 31 and 45 mSv to their left eye. These results are for an “unprotected” eye, and for IR staff who routinely wear lead glasses, the dose beneath the glasses is likely to be significantly lower. Staff eye dose normalized to patient kerma–area product and eye dose per procedure have been included in the analysis. Conclusion: Eye doses to IR operators have been established using a dedicated Hp(3) dosemeter. Estimated annual doses have the potential to exceed the new ICRP limit. Advances in knowledge: We have estimated lens dose to interventional radiologists in terms of Hp(3) for the first time in an Irish hospital setting. PMID:25761211
Paulke-Korinek, Maria; Kollaritsch, Herwig; Kundi, Michael; Zwazl, Ines; Seidl-Friedrich, Claudia; Jelinek, Tomas
2015-07-09
Japanese Encephalitis (JE) virus occurs in wide regions of Asia with over 3 billion people living in areas at risk for JE. An estimated 68,000 clinical cases of JE occur every year, and vaccination is the most effective prophylactic measure. One internationally licensed vaccine containing the inactivated JE virus strain SA14-14-2 is Ixiaro (Valneva, Austria). According to recommendations, basic immunization consists of vaccinations on day 0, day 28, and a booster dose 12-24 months later. Protection in terms of neutralizing antibody titers has been assessed up to 12 months after the third dose of the vaccine. The current investigation was designed to evaluate antibody decline over time and to predict long-term duration of seroprotection after a booster dose. In a preceding trial, volunteers received basic immunization (day 0, day 28) and one booster dose against JE 15 months later. A follow up blood draw 6 years following their booster dose was carried out in 67 subjects. For antibody testing, a 50% plaque reduction neutralization test (PRNT50-test) was used. PRNT50 values of 10 and above are surrogate levels of protection according to WHO standards. Seventy-six months following the booster dose, 96% of the tested subjects had PRNT50 titers of 10 or higher. Geometric mean titer (GMT) was 148 (95% CI confidence interval: 107-207). Antibody titers were lower in volunteers 50 years of age and older. Vaccination history against other flaviviruses (yellow fever or tick borne encephalitis) did not significantly influence PRNT50 titers. A two-step log-linear decline model predicted protection against JE of approximately 14 years after the booster dose. Six years after a booster dose against JE, long-term protection could be demonstrated. According to our results, further booster doses should be scheduled 10 years following the first booster dose. Copyright © 2015 Elsevier Ltd. All rights reserved.
Martinez, José Manuel; Pereira, Dulcineia; Chacim, Sérgio; Mesquita, Edgar; Sousa, Inês; Martins, Ângelo; Azevedo, Teresa; Mariz, José Mário
2014-09-01
This study intends to provide new insights into the incidence and care of mucositis by the epidemiological characterization of patients with hematological malignancy treated at our institution. It also aims to understand the effectiveness of several treatments used. This is a longitudinal observational single-center study-convenience sample-which includes malignant hematologic inpatients submitted to high-dose CT from February to August 2012. We registered epidemiological data, diagnosis, oral mucositis daily questionnaire (OMDQ), World Health Organization (WHO) oral toxicity scale, and supportive medications used for mucositis. We evaluated 30 patients who had 73 episodes of hospitalization, having recorded the development of mucositis in 21.9 % (n = 16) episodes (22 patients with acute leukemia (AL) and 8 patients with non-Hodgkin lymphoma (NHL)). Grades 3-4 mucositis was reported in 4.1 % of the total episodes. The results of OMDQ showed some limitations in the quality of life, of patients with mucositis, related with the ability to eat and drink due to mouth pain (p < 0.001). In patients with NHL and AL, neutropenia entails an increased risk of mucositis (p < 0.001). Patients who did not initiate early prophylaxis with conservative measures developed mucositis earlier (p < 0.05). The incidence of mucositis is high, being reported mainly in AL patients, with limitations in quality of life. Grade 4 neutropenia increases mucositis risk. Early prophylaxis with basic oral care may delay mucositis. Further studies are crucial to characterize mucositis epidemiology, physiopathology, and its management.
ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology.
Khong, P-L; Ringertz, H; Donoghue, V; Frush, D; Rehani, M; Appelgate, K; Sanchez, R
2013-04-01
Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities - radiography and fluoroscopy, interventional radiology, and computed tomography - are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation, use of protective shielding, optimisation of exposure factors, use of pulsed fluoroscopy, limiting fluoroscopy time, etc. Major paediatric interventional procedures should be performed by experienced paediatric interventional operators, and a second, specific level of training in radiological protection is desirable (in some countries, this is mandatory). For computed tomography, dose reduction should be optimised by the adjustment of scan parameters (such as mA, kVp, and pitch) according to patient weight or age, region scanned, and study indication (e.g. images with greater noise should be accepted if they are of sufficient diagnostic quality). Other strategies include restricting multiphase examination protocols, avoiding overlapping of scan regions, and only scanning the area in question. Up-to-date dose reduction technology such as tube current modulation, organ-based dose modulation, auto kV technology, and iterative reconstruction should be utilised when appropriate. It is anticipated that this publication will assist institutions in encouraging the standardisation of procedures, and that it may help increase awareness and ultimately improve practices for the benefit of patients. Copyright © 2012. Published by Elsevier Ltd.
Liquid Medication Dosing Errors by Hispanic Parents: Role of Health Literacy and English Proficiency
Harris, Leslie M.; Dreyer, Benard; Mendelsohn, Alan; Bailey, Stacy C.; Sanders, Lee M.; Wolf, Michael S.; Parker, Ruth M.; Patel, Deesha A.; Kim, Kwang Youn A.; Jimenez, Jessica J.; Jacobson, Kara; Smith, Michelle; Yin, H. Shonna
2016-01-01
Objective Hispanic parents in the US are disproportionately affected by low health literacy and limited English proficiency (LEP). We examined associations between health literacy, LEP, and liquid medication dosing errors in Hispanic parents. Methods Cross-sectional analysis of data from a multisite randomized controlled experiment to identify best practices for the labeling/dosing of pediatric liquid medications (SAFE Rx for Kids study); 3 urban pediatric clinics. Analyses were limited to Hispanic parents of children <8 years, with health literacy and LEP data (n=1126). Parents were randomized to 5 groups that varied by pairing of units of measurement on the label/dosing tool. Each parent measured 9 doses [3 amounts (2.5,5,7.5 mL) using 3 tools (2 syringes (0.2,0.5 mL increment), 1 cup)] in random order. Dependent variable: Dosing error=>20% dose deviation. Predictor variables: health literacy (Newest Vital Sign) [limited=0–3; adequate=4–6], LEP (speaks English less than “very well”). Results 83.1% made dosing errors (mean(SD) errors/parent=2.2(1.9)). Parents with limited health literacy and LEP had the greatest odds of making a dosing error compared to parents with adequate health literacy who were English proficient (% trials with errors/parent=28.8 vs. 12.9%; AOR=2.2[1.7–2.8]). Parents with limited health literacy who were English proficient were also more likely to make errors (% trials with errors/parent=18.8%; AOR=1.4[1.1–1.9]). Conclusion Dosing errors are common among Hispanic parents; those with both LEP and limited health literacy are at particular risk. Further study is needed to examine how the redesign of medication labels and dosing tools could reduce literacy and language-associated disparities in dosing errors. PMID:28477800
Gunko, N V
2015-12-01
Evaluation of efficacy of the managed population transmigration from zone of obligate (compulsory) resettlement as a measure of civil protection after the Chernobyl NPP accident from the perspective of radiation biology. Legislative and statutory tutorial documents that regulate the managed population shift from radiologically contaminated territories of Ukraine and data from the Ukrainian State Service of Statistics on time limits and scopes of population transmigration from contaminated settlements were the informational back ground of the study. Data on retrospective and expected/anticipated radiation doses in population of settlements exposed to radiological contamination in Ukraine after the Chernobyl disaster summarized for the 1986-1997 peri od and up to 2055 were the information source for calculation of averted doses due to population shift. Battery of basic research empirical evidence review methods was applied under the calculation, systemic, and biomedical approach. Population shift from zone of obligate (compulsore) resettlement (hereafter referred to as Zone 2) to stop the radiation exposure as a tool of civil protection from emergency ionizing radiation after the Chernobyl NPP accident was scientifically substantiated and expedient from the perspective of radiation biology. Estimability of a managed population shift from "dose effect" perspective and "benefit/harm" principle is worse because of data absence on individual radiation doses to migrants in the country. Public shift in 1990 and 1991 was most effective from the viewpoint of level of averted lifetime dose. Due to transmigration the averted lifetime dose to the most vulnerable group of the Chernobyl disaster survivors i.e. children aged 0 years varied from 11.2 to 28.8 mSv (calculated for the Perejizdiv village council of Zhytomyr province). Since 2000 there was almost no public shift being not accomplished in the scheduled scope. Delay and incompleteness of transmigration have diminished the efficacy of this measure in the framework of radiological protection of population. N. V. Gunko.
ten Berge, Hein F M; van der Meer, Hugo G; Steenhuizen, Johan W; Goedhart, Paul W; Knops, Pol; Verhagen, Jan
2012-01-01
Mineral carbonation of basic silicate minerals regulates atmospheric CO(2) on geological time scales by locking up carbon. Mining and spreading onto the earth's surface of fast-weathering silicates, such as olivine, has been proposed to speed up this natural CO(2) sequestration ('enhanced weathering'). While agriculture may offer an existing infrastructure, weathering rate and impacts on soil and plant are largely unknown. Our objectives were to assess weathering of olivine in soil, and its effects on plant growth and nutrient uptake. In a pot experiment with perennial ryegrass (Lolium perenne L.), weathering during 32 weeks was inferred from bioavailability of magnesium (Mg) in soil and plant. Olivine doses were equivalent to 1630 (OLIV1), 8150, 40700 and 204000 (OLIV4) kg ha(-1). Alternatively, the soluble Mg salt kieserite was applied for reference. Olivine increased plant growth (+15.6%) and plant K concentration (+16.5%) in OLIV4. At all doses, olivine increased bioavailability of Mg and Ni in soil, as well as uptake of Mg, Si and Ni in plants. Olivine suppressed Ca uptake. Weathering estimated from a Mg balance was equivalent to 240 kg ha(-1) (14.8% of dose, OLIV1) to 2240 kg ha(-1) (1.1%, OLIV4). This corresponds to gross CO(2) sequestration of 290 to 2690 kg ha(-1) (29 10(3) to 269 10(3) kg km(-2).) Alternatively, weathering estimated from similarity with kieserite treatments ranged from 13% to 58% for OLIV1. The Olsen model for olivine carbonation predicted 4.0% to 9.0% weathering for our case, independent of olivine dose. Our % values observed at high doses were smaller than this, suggesting negative feedbacks in soil. Yet, weathering appears fast enough to support the 'enhanced weathering' concept. In agriculture, olivine doses must remain within limits to avoid imbalances in plant nutrition, notably at low Ca availability; and to avoid Ni accumulation in soil and crop.
ten Berge, Hein F. M.; van der Meer, Hugo G.; Steenhuizen, Johan W.; Goedhart, Paul W.; Knops, Pol; Verhagen, Jan
2012-01-01
Mineral carbonation of basic silicate minerals regulates atmospheric CO2 on geological time scales by locking up carbon. Mining and spreading onto the earth's surface of fast-weathering silicates, such as olivine, has been proposed to speed up this natural CO2 sequestration (‘enhanced weathering’). While agriculture may offer an existing infrastructure, weathering rate and impacts on soil and plant are largely unknown. Our objectives were to assess weathering of olivine in soil, and its effects on plant growth and nutrient uptake. In a pot experiment with perennial ryegrass (Lolium perenne L.), weathering during 32 weeks was inferred from bioavailability of magnesium (Mg) in soil and plant. Olivine doses were equivalent to 1630 (OLIV1), 8150, 40700 and 204000 (OLIV4) kg ha−1. Alternatively, the soluble Mg salt kieserite was applied for reference. Olivine increased plant growth (+15.6%) and plant K concentration (+16.5%) in OLIV4. At all doses, olivine increased bioavailability of Mg and Ni in soil, as well as uptake of Mg, Si and Ni in plants. Olivine suppressed Ca uptake. Weathering estimated from a Mg balance was equivalent to 240 kg ha−1 (14.8% of dose, OLIV1) to 2240 kg ha−1 (1.1%, OLIV4). This corresponds to gross CO2 sequestration of 290 to 2690 kg ha−1 (29 103 to 269 103 kg km−2.) Alternatively, weathering estimated from similarity with kieserite treatments ranged from 13% to 58% for OLIV1. The Olsen model for olivine carbonation predicted 4.0% to 9.0% weathering for our case, independent of olivine dose. Our % values observed at high doses were smaller than this, suggesting negative feedbacks in soil. Yet, weathering appears fast enough to support the ‘enhanced weathering’ concept. In agriculture, olivine doses must remain within limits to avoid imbalances in plant nutrition, notably at low Ca availability; and to avoid Ni accumulation in soil and crop. PMID:22912685
Targeted analysis of 116 drugs in hair by UHPLC-MS/MS and its application to forensic cases.
Wang, Xin; Johansen, Sys Stybe; Nielsen, Marie Katrine Klose; Linnet, Kristian
2017-08-01
A multi-target method that can detect a broad range of drugs in human hair, such as hypnotics, anxiolytics, analgesics, benzodiazepines, antihistamines, antidepressants, antipsychotics, and anticonvulsants, was developed based on ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The drugs were extracted from 10 mg of washed hair by incubation for 18 h in a 25:25:50 (v/v/v) mixture of methanol/acetonitrile/2 mM ammonium formate (8% acetonitrile, pH 5.3). For 51% of the basic drugs, the lower limits of quantification (LLOQs) were in the range of 0.05-0.5 pg/mg, and the majority (98%) were ≤ 5 pg/mg. Linearity ranged from LLOQs to 100-500 pg/mg for all the basic drugs. For acid and neutral drugs, the LLOQs ranged from 0.4 to 500 pg/mg, and linearity ranged from LLOQs to 80-40 000 pg/mg. According to published reports on concentrations attained in single dose control studies, the present method is sensitive enough to detect single-dose drug exposure for many of the drugs. The accuracy was within 75-125% for the majority of drugs. Good precision was observed (relative standard deviations [RSD%] < 25%) for most of the compounds, including the prepared quality control (QC) hair samples. The method was applied to forensic cases and concentrations of rarely reported drugs in hair in 25 post-mortem forensic cases were presented. Hair concentrations of amisulpride, gabapentin, mianserin, mepyramine, orphenadrine, and xylometazoline have not been previously reported. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
New Stochastic Annual Limits on Intake for Selected Radionuclides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, Eugene H.
Annual limits on intake (ALI) have historically been tabulated by the International Commission on Radiological Protection (e.g., ICRP 1979, 1961) and also by the Environmental Protection Agency (EPA 1988). These compilations have been rendered obsolete by more recent ICRP dosimetry methods, and, rather than provide new ALIs, the ICRP has opted instead to provide committed dose coefficients from which an ALI can be determined by a user for a specific set of conditions. The U.S. Department of Energy historically has referenced compilations of ALIs and has defined their method of calculation in its radiation protection regulation (10 CFDR 835), butmore » has never provided a specific compilation. Under June 2007 amendments to 10 CFR 835, ALIs can be calculated by dividing an appropriate dose limit, either 5-rem (0.05 Sv) effective dose or 50 rem (0.5 Sv) equivalent dose to an individual organ or tissue, by an appropriate committed dose coefficient. When based on effective dose, the ALI is often referred to as a stochastic annual limit on intake (SALI), and when based on the individual organ or tissue equivalent limit, it has often been called a deterministic annual limit on intake (DALI).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dufour, R.; Collignon, Y.; Vincent, F.
1975-05-01
A method of simultaneous observation of several physiological functions was developed in the unanaesthetized rabbit. Arterial blood pressure, local brain circulation, internal body temperature and arterial blodd acido-basic balance were thus followed before, during and after $gamma$-irradiation. There appeared two periods in the development of this early syndrome: they were related to two processes, a central one, mainly of sympathetic origin was hardly sensitive to the dose, the other is dose-dependent. (FR)
The basic aerodynamics of floatation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davies, M.J.; Wood, D.H.
1983-09-01
The original derivation of the basic theory governing the aerodynamics of both hovercraft and modern floatation ovens, requires the validity of some extremely crude assumptions. However, the basic theory is surprisingly accurate. It is shown that this accuracy occurs because the final expression of the basic theory can be derived by approximating the full Navier-Stokes equations in a manner that clearly shows the limitations of the theory. These limitations are used in discussing the relatively small discrepancies between the theory and experiment, which may not be significant for practical purposes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andersen, R.L.; Schmitt, J.F.
1995-03-01
The International Commission on Radiological Protection and the National Council on Radiation Protection and Measurements have issued recommendations that would limit occupational exposure of individuals to doses lower than regulatory limits contained in the Nuclear Regulatory Commission`s 10 CFR Part 20, {open_quotes}Standards for Protection Against Radiation{close_quotes}. Because of this situation, there is interest in the potential benefits and impacts that would be associated with movement of the NRC regulatory limits toward the advisory bodies recommendations. The records of occupational worker doses in the U.S. commercial nuclear power industry show that the vast majority of these workers have doses that aremore » significantly below the regulatory limit of 50 mSv (5 rem) per year. Some workers doses do approach the limits, however. This is most common in the case of specially skilled workers, especially those with skills utilized in support of plant outage work. Any consideration of the potential benefits and impacts of hypothesized lower dose limits must address these workers as an important input to the overall assessment. There are also, of course, many other areas in which the benefits and impacts must be evaluated. To prepare to provide valid, constructive input on this matter, the U.S. nuclear power industry is undertaking an assessment, facilitated by the Nuclear Energy Institute (NEI), of the potential benefits and impacts at its facilities associated with hypothesized lower occupational dose limits. Some preliminary results available to date from this assessment are provided.« less
Bender, Julia Glade; Blaney, Susan M.; Borinstein, Scott; Reid, Joel M.; Baruchel, Sylvain; Ahern, Charlotte; Ingle, Ashish M.; Yamashiro, Darrell J.; Chen, Alice; Weigel, Brenda; Adamson, Peter C.; Park, Julie R.
2012-01-01
Background Aflibercept is a novel decoy receptor that efficiently neutralizes circulating vascular endothelial growth factor (VEGF). A pediatric phase 1 trial was performed to define the dose limiting toxicities (DLT), maximum tolerated dose (MTD) and pharmacokinetics (PK) of aflibercept. Methods Cohorts of 3–6 children with refractory solid tumors received aflibercept intravenously over 60 minutes every 14 days, at 2.0, 2.5 or 3.0 mg/kg/dose. PK sampling and analysis of peripheral blood biomarkers were performed with the initial dose. Results 21 eligible patients were enrolled; 18 were fully evaluable for toxicity. One of 6 patients receiving 2.0 mg/kg/dose developed dose-limiting intra-tumoral hemorrhage and 2 of 6 receiving 3.0 mg/kg/dose developed either dose-limiting tumor pain or tissue necrosis. None of the 6 patients receiving 2.5 mg/kg/dose developed DLT, defining this as the MTD. The most common non-dose limiting toxicities were hypertension and fatigue. Three patients with hepatocellular carcinoma, hepatoblastoma and clear cell sarcoma had stable disease for >13 weeks. At the MTD, the ratio of free to bound aflibercept serum concentration was 2.10 on day 8, but only 0.44 by day 15. A rapid decrease in VEGF (p<0.05) and increase in PlGF (p<0.05) from baseline was observed in response to aflibercept by day 2. Conclusion The aflibercept MTD in children of 2.5 mg/kg/dose every 14 days is lower that the adult recommended dose of 4.0 mg/kg. This dose achieves, but does not sustain, free aflibercept concentrations in excess of bound. Tumor pain and hemorrhage may be evidence of anti-tumor activity, but were dose-limiting. PMID:22791883
Decreasing Irradiated Rat Lung Volume Changes Dose-Limiting Toxicity From Early to Late Effects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veen, Sonja J. van der; Faber, Hette; Ghobadi, Ghazaleh
2016-01-01
Purpose: Technological developments in radiation therapy result in smaller irradiated volumes of normal tissue. Because the risk of radiation therapy-induced toxicity generally depends on irradiated volume, changing volume could change the dose-limiting toxicity of a treatment. Recently, in our rat model, we found that early radiation-induced lung dysfunction (RILD) was closely related to irradiated volume dependent vascular remodeling besides inflammation. The exact relationship between early and late RILD is still unknown. Therefore, in this preclinical study we investigated the dose-volume relationship of late RILD, assessed its dependence on early and late pathologies and studied if decreasing irradiated volume changed themore » dose-limiting toxicity. Methods and Materials: A volume of 25%, 32%, 50%, 63%, 88%, or 100% of the rat lung was irradiated using protons. Until 26 weeks after irradiation, respiratory rates were measured. Macrovascular remodeling, pulmonary inflammation, and fibrosis were assessed at 26 weeks after irradiation. For all endpoints dose-volume response curves were made. These results were compared to our previously published early lung effects. Results: Early vascular remodeling and inflammation correlated significantly with early RILD. Late RILD correlated with inflammation and fibrosis, but not with vascular remodeling. In contrast to the early effects, late vascular remodeling, inflammation and fibrosis showed a primarily dose but not volume dependence. Comparison of respiratory rate increases early and late after irradiation for the different dose-distributions indicated that with decreasing irradiated volumes, the dose-limiting toxicity changed from early to late RILD. Conclusions: In our rat model, different pathologies underlie early and late RILD with different dose-volume dependencies. Consequently, the dose-limiting toxicity changed from early to late dysfunction when the irradiated volume was reduced. In patients, early and late RILD are also due to different pathologies. As such, new radiation techniques reducing irradiated volume might change the dose-limiting toxicity of the radiation therapy treatment.« less
Yazici, Hasan; Gogus, Feride; Esen, Fehim; Yazici, Yusuf
2014-06-01
There is concern that self-critique with authors acknowledging limitations of their work is not given due importance in scientific articles. We had the impression that this was more true for articles in basic compared with clinical science. We thus surveyed for the presence of self-critique in the discussion sections of the original articles in three rheumatology journals with attention to differences between the basic and the clinical science articles. The discussion sections of the original articles in January, May, and September 2012 issues of Annals of the Rheumatic Diseases, Arthritis and Rheumatism, and Rheumatology (Oxford) were surveyed (n = 223) after classifying each article as mainly related to clinical or basic science. The discussion sections were electronically scanned by two observers for the presence of the root word "limit" or its derivatives who also read each discussion section for the presence of any limitations otherwise voiced. A limitation discussion in any form was present in only 19 (20.2%) or 29 (30.1%) of 94 basic science vs. 95 (73.6%) or 107 (82.3%) of 129 clinical science articles (P < 0.0001 for either observer). Self-critique, especially lacking in basic science articles, should be given due attention. Copyright © 2014 Elsevier Inc. All rights reserved.
TH-E-202-02: The Use of Hypoxia PET Imaging for Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Humm, J.
2016-06-15
PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy.more » The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the basics of using FDG PET/CT for tumor response evaluation. Learn about recent advancement in PET/CT radiomics and non-FDG PET tracers for response assessment. This work was supported in part by the National Cancer Institute Grants R01CA172638.; W. Lu, This work was supported in part by the National Cancer Institute Grants R01CA172638.« less
TH-E-202-00: PET for Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy.more » The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the basics of using FDG PET/CT for tumor response evaluation. Learn about recent advancement in PET/CT radiomics and non-FDG PET tracers for response assessment. This work was supported in part by the National Cancer Institute Grants R01CA172638.; W. Lu, This work was supported in part by the National Cancer Institute Grants R01CA172638.« less
TH-E-202-03: PET for Tumor Response Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, W.
PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy.more » The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the basics of using FDG PET/CT for tumor response evaluation. Learn about recent advancement in PET/CT radiomics and non-FDG PET tracers for response assessment. This work was supported in part by the National Cancer Institute Grants R01CA172638.; W. Lu, This work was supported in part by the National Cancer Institute Grants R01CA172638.« less
Rampling, Roy; Sanson, Marc; Gorlia, Thiery; Lacombe, Denis; Lai, Christina; Gharib, Myriam; Taal, Walter; Stoffregen, Clemens; Decker, Rodney; van den Bent, Martin J.
2012-01-01
We report a phase 1 study to examine the safety and recommended dose of the oral protein kinase C-beta inhibitor (anti-angiogenic) enzastaurin in combination with single-agent temozolomide. The study was conducted in patients with recurrent glioblastoma or newly diagnosed disease that was not treatable with standard (chemo)radiotherapy. Patients were treated with standard dose temozolomide (200 mg/m2 for 5 days every 4 weeks) together with daily oral enzastaurin. Three dose levels of enzastaurin were investigated: 250 mg daily (OD), 500 mg OD, and 250 mg twice daily (BID). Dose-limiting toxicity was determined in the first 2 cycles, but treatment continued until limiting toxicity or disease progression was identified. Twenty-eight patients were enrolled. No dose-limiting toxicity was noted at 250 mg OD or 500 mg OD. However, at 250 mg BID, 2 dose-limiting episodes of thrombocytopenia were noted. The recommended dose for enzastaurin in combination with standard 4-weekly temozolomide is therefore 500 mg OD. The pharmacokinetics of enzastaurin in combination with temozolomide was evaluated. Temozolomide did not appear to effect enzastaurin exposures at the 250 mg or 500 mg OD dose levels. PMID:22291006
Galactic and Solar Cosmic Ray Shielding in Deep Space
NASA Technical Reports Server (NTRS)
Wilson, John W.; Cucinotta, Francis A.; Tai, H.; Simonsen, Lisa C.; Shinn, Judy L.; Thibeault, Shelia; Kim, M. Y.
1997-01-01
An analysis of the radiation hazards in support of NASA deep space exploration activities is presented. The emphasis is on materials required for radiation protection shielding. Aluminum has been found to be a poor shield material when dose equivalent is used with exposure limits for low Earth orbit (LEO) as a guide for shield requirements. Because the radiation issues are cost related-the parasitic shield mass has high launch costs, the use of aluminum as a basic construction material is clearly not cost-effective and alternate materials need to be developed. In this context, polyethylene is examined as a potentially useful material and demonstrates important advantages as an alternative to aluminum construction. Although polyethylene is useful as a shield material, it may not meet other design criteria (strength, stability, thermal); other polymer materials must be examined.
Requirements for authorisation of internal dosimetry services.
Melo, D R; Cunha, P G; Torres, M M C; Lourenço, M C
2003-01-01
In order to ensure that a facility is in compliance with the occupational exposure requirements established by regulatory authorities, the measurements and dose assessments specified in the individual monitoring programme need to be reliable. There are two important questions that shall be addressed here: one is how the licensed facilities can demonstrate to their workers and regulatory bodies compliance with the regulatory limits and the reliability of the results of the individual monitoring programmes; the other concerns the mechanisms used to demonstrate to a facility in another country the reliability of the measurement results of an individual monitoring bioassay programme. The accreditation of the bioassay laboratory, according to ISO/IEC 17025, shall be the basic requirement for obtaining the authorisation granted by the national regulatory authority. For the second question, such confidence can be achieved through International Laboratory Accreditation Cooperation (ILAC).
Multiple Consecutive Infections Might Explain the Lack of Protection by BCG
Cardona, Pere-Joan; Vilaplana, Cristina
2014-01-01
Although contacts between tuberculosis patients may result in multiple consecutive infections (MCI), no experimental animal models consider this fact when used in basic studies. Moreover, the current TB vaccine (BCG) has demonstrated a limited protection in humans. In this study we evaluate the effect of tuberculosis MCI by way of a simple mathematical analysis using data from the low dose aerosol murine experimental model. The results show that a higher number of, or shorter intervals between, multiple consecutive infections reduce the protective effect of BCG. This is due to both the increase in bacillary load at the stationary level of the infection, and the protective immune response induced by the infection itself. This factor must therefore be taken into account when designing new prophylactic strategies as candidate vaccines for the replacement of BCG. PMID:24740286
Multiple consecutive infections might explain the lack of protection by BCG.
Cardona, Pere-Joan; Vilaplana, Cristina
2014-01-01
Although contacts between tuberculosis patients may result in multiple consecutive infections (MCI), no experimental animal models consider this fact when used in basic studies. Moreover, the current TB vaccine (BCG) has demonstrated a limited protection in humans. In this study we evaluate the effect of tuberculosis MCI by way of a simple mathematical analysis using data from the low dose aerosol murine experimental model. The results show that a higher number of, or shorter intervals between, multiple consecutive infections reduce the protective effect of BCG. This is due to both the increase in bacillary load at the stationary level of the infection, and the protective immune response induced by the infection itself. This factor must therefore be taken into account when designing new prophylactic strategies as candidate vaccines for the replacement of BCG.
Koivisto, Juha H; Wolff, Jan E; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika
2015-07-08
The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in vivo measurements (<1.7 mGy) the sensitivity is too low.
... Home / Digestive Health Topic / Non-cardiac Chest Pain Non-cardiac Chest Pain Basics Overview and Symptoms What ... at a reduced dose such as Omeprazole (or equivalent PPI medication ) 20 mg twice daily about 40 ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Q
Purpose: According to clinical and research requirement, we develop a function of automatic reading dose of interest from dose volume histogram(DVH), to replace the traditional method with a mouse one by one point, and it's also verified. Methods: The DVH automatic reading function will be developed in an in-house developed radiotherapy information management system(RTIMS), which is based on Apache+PHP+MySQL. A DVH ASCII file is exported from Varian Eclipse V8.6, which includes the following contents: 1. basic information of patient; 2. dose information of plan; 3. dose information of structures, including basic information and dose volume data of target volume andmore » organ at risk. And the default exported dose volume data also includes relative doses by 1% step and corresponding absolute doses and cumulative relative volumes, and the volumes are 4 decimal fraction. Clinically, we often need read the doses of some integer percent volumes, such as D50 and D30. So it couldn't be directly obtained from the above data, but we can use linear interpolation bye the near volumes and doses: Dx=D2−(V2−Vx)*(D2−D1)/(V2−V1), and program a function to search, read and calculate the corresponding data. And the doses of all preseted volume of interest of all structures can be automatically read one by one patient, and saved as a CSV file. To verify it, we select 24 IMRT plans for prostate cancer, and doses of interest are PTV D98/D95/D5/D2, bladder D30/D50, and rectum D25/D50. Two groups of data, using the automatic reading method(ARM) and pointed dose method(PDM), are analyzed with SPSS 16. The absolute difference=D-ARM-D-PDM, relative difference=absolute difference*100%/prescription dose(7600cGy). Results: The differences are as following: PTV D98/D95/D5/D2: −0.04%/− 0.04%/0.13%/0.19%, bladder D30/D50: −0.02%/0.01%, and rectum D25/D50: 0.03%/0.01%. Conclusion: Using this function, the error is very small, and can be neglected. It could greatly improve the efficiency of clinical work. Project supported by the National Natural Science Foundation of China (Grant No.81101694)« less
Ligumsky, Moshe; Badaan, Shadi; Lewis, Hadassa; Meirow, Dror
2005-04-01
Azathioprine and 6-mercaptopurine interact in purine metabolism and DNA synthesis, thus their potential mutagenic effects have been of concern in the management of inflammatory bowel disease (IBD), especially in patients of childbearing age. Although several clinical studies have indicated their safety in both reproduction and pregnancy, in a recent large epidemiological study concerns were raised about their adverse effects in pregnant patients with IBD, and experimental or basic data on this subject are limited. The aim of this study was to investigate sperm production, sperm quality, and reproductive outcome following prolonged 6-MP administration to male mice. Highly inbred Balb/c adult male mice were used. 6-MP at doses of 2, 5, and 8 mg/kg (n = 9 for each group) was given daily for 51 days and the treatment group was compared with controls. After 45 days of treatment, the mice were mated with females. Following 13 days of pregnancy, the products of conception were evaluated and live fetuses were examined for gross malformations. Sperm production and morphology were examined after 51 days of 6-MP administration. Treatment with 6-MP at all doses did not affect sperm morphology and sperm production in the testicular tubules, as compared with controls (70% normal sperm). However, pregnancy rates were inversely related to escalating doses of 6-MP: 55%, 41%, 28%, and 16% for control, 2, 5, and 8 mg/kg groups, respectively. Resorption rates (abortions) were 21% in the control group as compared with 45-50% in all the treatment groups, but the incidence of major congenital malformations was not increased. Long-term 6-MP treatment in male mice did not impair sperm production and sperm morphology. However, a significantly high rate of embryonic resorption indicated occult sperm damage. Thus, normal sperm analysis does not necessarily imply that sperm damage at genetic level did not occur. It is difficult to extrapolate from these results to the clinical use of 6-MP/azathioprine in IBD patients; however, further basic genetic testing for DNA damage and clinical follow-up are warranted.
Matching of electron beams for conformal therapy of target volumes at moderate depths.
Zackrisson, B; Karlsson, M
1996-06-01
The basic requirements for conformal electron therapy are an accelerator with a wide range of energies and field shapes. The beams should be well characterised in a full 3-D dose planning system which has been verified for the geometries of the current application. Differences in the basic design of treatment units have been shown to have a large influence on beam quality and dosimetry. Modern equipment can deliver electron beams of good quality with a high degree of accuracy. A race-track microtron with minimised electron scattering and a multi-leaf collimator (MLC) for electron collimating will facilitate the isocentric technique as a general treatment technique for electrons. This will improve the possibility of performing combined electron field techniques in order to conform the dose distribution with no or minimal use of a bolus. Furthermore, the isocentric technique will facilitate multiple field arrangements that decrease the problems with distortion of the dose distribution due to inhomogeneities, etc. These situations are demonstrated by clinical examples where isocentric, matched electron fields for treatment of the nose, thyroid and thoracic wall have been used.
10 CFR 835.202 - Occupational dose limits for general employees.
Code of Federal Regulations, 2010 CFR
2010-01-01
... tissue other than the skin or the lens of the eye of 50 rems (0.5 Sv); (3) An equivalent dose to the lens of the eye of 15 rems (0.15 Sv); and (4) The sum of the equivalent dose to the skin or to any... 10 Energy 4 2010-01-01 2010-01-01 false Occupational dose limits for general employees. 835.202...
10 CFR 835.202 - Occupational dose limits for general employees.
Code of Federal Regulations, 2014 CFR
2014-01-01
... tissue other than the skin or the lens of the eye of 50 rems (0.5 Sv); (3) An equivalent dose to the lens of the eye of 15 rems (0.15 Sv); and (4) The sum of the equivalent dose to the skin or to any... 10 Energy 4 2014-01-01 2014-01-01 false Occupational dose limits for general employees. 835.202...
10 CFR 835.202 - Occupational dose limits for general employees.
Code of Federal Regulations, 2012 CFR
2012-01-01
... tissue other than the skin or the lens of the eye of 50 rems (0.5 Sv); (3) An equivalent dose to the lens of the eye of 15 rems (0.15 Sv); and (4) The sum of the equivalent dose to the skin or to any... 10 Energy 4 2012-01-01 2012-01-01 false Occupational dose limits for general employees. 835.202...
10 CFR 835.202 - Occupational dose limits for general employees.
Code of Federal Regulations, 2013 CFR
2013-01-01
... tissue other than the skin or the lens of the eye of 50 rems (0.5 Sv); (3) An equivalent dose to the lens of the eye of 15 rems (0.15 Sv); and (4) The sum of the equivalent dose to the skin or to any... 10 Energy 4 2013-01-01 2013-01-01 false Occupational dose limits for general employees. 835.202...
10 CFR 835.202 - Occupational dose limits for general employees.
Code of Federal Regulations, 2011 CFR
2011-01-01
... tissue other than the skin or the lens of the eye of 50 rems (0.5 Sv); (3) An equivalent dose to the lens of the eye of 15 rems (0.15 Sv); and (4) The sum of the equivalent dose to the skin or to any... 10 Energy 4 2011-01-01 2011-01-01 false Occupational dose limits for general employees. 835.202...
10 CFR 20.1201 - Occupational dose limits for adults.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Occupational dose limits for adults. 20.1201 Section 20.1201 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose... surveys or other radiation measurements for the purpose of demonstrating compliance with the occupational...
10 CFR 20.1201 - Occupational dose limits for adults.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Occupational dose limits for adults. 20.1201 Section 20.1201 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose... surveys or other radiation measurements for the purpose of demonstrating compliance with the occupational...
10 CFR 20.1201 - Occupational dose limits for adults.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Occupational dose limits for adults. 20.1201 Section 20.1201 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose... surveys or other radiation measurements for the purpose of demonstrating compliance with the occupational...
10 CFR 20.1201 - Occupational dose limits for adults.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Occupational dose limits for adults. 20.1201 Section 20.1201 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose... surveys or other radiation measurements for the purpose of demonstrating compliance with the occupational...
10 CFR 20.1201 - Occupational dose limits for adults.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Occupational dose limits for adults. 20.1201 Section 20.1201 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose... surveys or other radiation measurements for the purpose of demonstrating compliance with the occupational...
NASA Technical Reports Server (NTRS)
Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.
1989-01-01
The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.
Bouffler, Simon; Ainsbury, Elizabeth; Gilvin, Phil; Harrison, John
2012-12-01
This paper presents the response of the Health Protection Agency (HPA) to the 2011 statement from the International Commission on Radiological Protection (ICRP) on tissue reactions and recommendation of a reduced dose limit for the lens of the eye. The response takes the form of a brief review of the most recent epidemiological and mechanistic evidence. This is presented together with a discussion of dose limits in the context of the related risk and the current status of eye dosimetry, which is relevant for implementation of the limits. It is concluded that although further work is desirable to quantify better the risk at low doses and following protracted exposures, along with research into the mechanistic basis for radiation cataractogenesis to inform selection of risk projection models, the HPA endorses the conclusion reached by the ICRP in their 2011 statement that the equivalent dose limit for the lens of the eye should be reduced from 150 to 20 mSv per year, averaged over a five year period, with no year's dose exceeding 50 mSv.
Tommasino, Francesco; Friedrich, Thomas; Jakob, Burkhard; Meyer, Barbara; Durante, Marco; Scholz, Michael
2015-01-01
We present here an analysis of DSB induction and processing after irradiation with X-rays in an extended dose range based on the use of the γH2AX assay. The study was performed by quantitative flow cytometry measurements, since the use of foci counting would result in reasonable accuracy only in a limited dose range of a few Gy. The experimental data are complemented by a theoretical analysis based on the GLOBLE model. In fact, original aim of the study was to test GLOBLE predictions against new experimental data, in order to contribute to the validation of the model. Specifically, the γH2AX signal kinetics has been investigated up to 24 h after exposure to increasing photon doses between 2 and 500 Gy. The prolonged persistence of the signal at high doses strongly suggests dose dependence in DSB processing after low LET irradiation. Importantly, in the framework of our modelling analysis, this is related to a gradually increased fraction of DSB clustering at the micrometre scale. The parallel study of γH2AX dose response curves shows the onset of a pronounced saturation in two cell lines at a dose of about 20 Gy. This dose is much lower than expected according to model predictions based on the values usually adopted for the DSB induction yield (≈ 30 DSB/Gy) and for the γH2AX foci extension of approximately 2 Mbp around the DSB. We show and discuss how theoretical predictions and experimental findings can be in principle reconciled by combining an increased DSB induction yield with the assumption of a larger genomic extension for the single phosphorylated regions. As an alternative approach, we also considered in our model the possibility of a 3D spreading-mechanism of the H2AX phosphorylation around the induced DSB, and applied it to the analysis of both the aspects considered. Our results are found to be supportive for the basic assumptions on which GLOBLE is built. Apart from giving new insights into the H2AX phosphorylation process, experiments performed at high doses are of relevance in the context of radiation therapy, where hypo-fractionated schemes become increasingly popular. PMID:26067661
Pleguezuelos, Olga; Robinson, Stuart; Stoloff, Gregory A; Caparrós-Wanderley, Wilson
2012-06-29
Current Influenza vaccines elicit antibody mediated prophylactic immunity targeted to viral capsid antigens. Despite their global use these vaccines must be administered yearly to the population, cannot be manufactured until the circulating viral strain(s) have been identified and have limited efficacy. A need remains for Influenza vaccines addressing these issues and here we report the results of a Phase Ib trial of a novel synthetic Influenza vaccine (FLU-v) targeting T cell responses to NP, M1 and M2. Forty-eight healthy males aged 18-40 were recruited for this single-centre, randomised, double blind study. Volunteers received one single low (250 μg) or high (500 μg) dose of FLU-v, either alone or adjuvanted. Safety, tolerability and basic immunogenicity (IgG and IFN-γ responses) parameters were assessed pre-vaccination and for 21 days post-vaccination. FLU-v was found to be safe and well tolerated with no vaccine associated severe adverse events. Dose-dependent IFN-γ responses >2-fold the pre-vaccination level were detected in 80% and 100% of volunteers receiving, respectively, the low and high dose adjuvanted FLU-v formulations. No formulation tested induced any significant FLU-v antibody response. FLU-v is safe and induces a vaccine-specific cellular immunity. Cellular immune responses are historically known to control and mitigate infection and illness during natural infection. Copyright © 2012 Elsevier Ltd. All rights reserved.
Progress toward poliomyelitis eradication - Afghanistan and Pakistan, 2009.
2010-03-12
Afghanistan, Pakistan, India, and Nigeria are the four remaining countries where indigenous wild poliovirus (WPV) transmission has never been interrupted. This report updates previous reports and describes polio eradication activities in Afghanistan and Pakistan during January-December 2009 and proposed activities in 2010 to address challenges. During 2009, both countries continued to conduct coordinated supplemental immunization activities (SIAs) and used multiple strategies to reach previously unreached children. These strategies included 1) use of short interval additional dose (SIAD) SIAs to administer a dose of oral poliovirus vaccine (OPV) within 1-2 weeks after a prior dose during negotiated periods of security; 2) systematic engagement of local leaders; 3) negotiations with conflict parties; and 4) increased engagement of nongovernmental organizations delivering basic health services. However, security problems continued to limit access by vaccination teams to large numbers of children. In Afghanistan, poliovirus transmission during 2009 predominantly occurred in 12 high-risk districts in the conflict-affected South Region; 38 WPV cases were confirmed in 2009, compared with 31 in 2008. In Pakistan, 89 WPV cases were confirmed in 2009, compared with 118 in 2008, but transmission persisted both in security-compromised areas and in accessible areas, where managerial and operational problems continued to affect immunization coverage. Continued efforts to enhance safe access of vaccination teams in insecure areas will be required for further progress toward interruption of WPV transmission in Afghanistan and Pakistan. In addition, substantial improvements in subnational accountability and oversight are needed to improve immunization activities in Pakistan.
Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit
2012-01-01
Background Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT) workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. Methods The audit was conducted in three radiotherapy departments of Serbia. An anthropomorphic phantom was scanned with a computed tomography unit (CT) and treatment plans for eight different test cases involving various beam configurations suggested by the IAEA were prepared on local treatment planning systems (TPSs). The phantom was irradiated following the treatment plans for these test cases and doses in specific points were measured with an ionization chamber. The differences between the measured and calculated doses were reported. Results The measurements were conducted for different photon beam energies and TPS calculation algorithms. The deviation between the measured and calculated values for all test cases made with advanced algorithms were within the agreement criteria, while the larger deviations were observed for simpler algorithms. The number of measurements with results outside the agreement criteria increased with the increase of the beam energy and decreased with TPS calculation algorithm sophistication. Also, a few errors in the basic dosimetry data in TPS were detected and corrected. Conclusions The audit helped the users to better understand the operational features and limitations of their TPSs and resulted in increased confidence in dose calculation accuracy using TPSs. The audit results indicated the shortcomings of simpler algorithms for the test cases performed and, therefore the transition to more advanced algorithms is highly desirable. PMID:22971539
Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit.
Rutonjski, Laza; Petrović, Borislava; Baucal, Milutin; Teodorović, Milan; Cudić, Ozren; Gershkevitsh, Eduard; Izewska, Joanna
2012-09-12
Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT) workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. The audit was conducted in three radiotherapy departments of Serbia. An anthropomorphic phantom was scanned with a computed tomography unit (CT) and treatment plans for eight different test cases involving various beam configurations suggested by the IAEA were prepared on local treatment planning systems (TPSs). The phantom was irradiated following the treatment plans for these test cases and doses in specific points were measured with an ionization chamber. The differences between the measured and calculated doses were reported. The measurements were conducted for different photon beam energies and TPS calculation algorithms. The deviation between the measured and calculated values for all test cases made with advanced algorithms were within the agreement criteria, while the larger deviations were observed for simpler algorithms. The number of measurements with results outside the agreement criteria increased with the increase of the beam energy and decreased with TPS calculation algorithm sophistication. Also, a few errors in the basic dosimetry data in TPS were detected and corrected. The audit helped the users to better understand the operational features and limitations of their TPSs and resulted in increased confidence in dose calculation accuracy using TPSs. The audit results indicated the shortcomings of simpler algorithms for the test cases performed and, therefore the transition to more advanced algorithms is highly desirable.
[Prophylaxis of alcoholic disease of the liver].
Beliakin, S A
2009-08-01
Military doctors should have a uniform position to the use of alcohol. Now alcohol is the basic pathogenic factor in development of a lethal cirrhosis of a liver. The most known sayings justifying the use of alcohol, are insolvent. Useful doses of alcohol does not exist. The quantity of used alcohol has the great value. Only at achievement of age 21 year it is possible to use safe doses of alcohol. A safe dose of pure alcohol (ethanol) less than 30,0 in day. In a basis of prophylaxis of a cirrhosis of a liver there is a medical educational activity.
Regulating exposure of the lens of the eye to ionising radiations.
Thorne, M C
2012-06-01
The International Commission on Radiological Protection (ICRP) has reviewed recent epidemiological evidence suggesting that, for the lens of the eye, the threshold in absorbed dose for the induction of deleterious health effects is about 0.5 Gy. On this basis, the Commission recommends that for occupational exposure in planned exposure situations, the equivalent dose limit for the lens of the eye should be 20 mSv in a year, averaged over defined periods of 5 yr, with exposure not exceeding 50 mSv in any single year. This paper summarises the data that have been taken into account by the ICRP and critically examines whether the proposed downward revision of the dose limit is justified. Overall, it is concluded that the accumulating radiobiological and epidemiological evidence makes it more appropriate to treat cataract induction as a stochastic rather than a deterministic effect. Within this framework, it is illogical to have the same dose limit for the lens of the eye as for the whole body irradiated uniformly. This could be addressed either by removing the special dose limit for the lens of the eye, assigning it an appropriate tissue weighting factor and including it in the computation of the effective dose, or through a composite approach involving the use of a tissue weighting factor for effective dose computations together with a special limit on the equivalent dose to the lens of the eye to ensure that no individual was subject to an unacceptably high risk of induction of clinically significant cataracts.
User Guide for GoldSim Model to Calculate PA/CA Doses and Limits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, F.
2016-10-31
A model to calculate doses for solid waste disposal at the Savannah River Site (SRS) and corresponding disposal limits has been developed using the GoldSim commercial software. The model implements the dose calculations documented in SRNL-STI-2015-00056, Rev. 0 “Dose Calculation Methodology and Data for Solid Waste Performance Assessment (PA) and Composite Analysis (CA) at the Savannah River Site”.
Calabrese, Edward J
2013-11-01
The most common quantitative feature of the hormetic-biphasic dose response is its modest stimulatory response which at maximum is only 30-60% greater than control values, an observation that is consistently independent of biological model, level of organization (i.e., cell, organ or individual), endpoint measured, chemical/physical agent studied, or mechanism. This quantitative feature suggests an underlying "upstream" mechanism common across biological systems, therefore basic and general. Hormetic dose response relationships represent an estimate of the peak performance of integrative biological processes that are allometrically based. Hormetic responses reflect both direct stimulatory or overcompensation responses to damage induced by relatively low doses of chemical or physical agents. The integration of the hormetic dose response within an allometric framework provides, for the first time, an explanation for both the generality and the quantitative features of the hormetic dose response. Copyright © 2013 Elsevier Ltd. All rights reserved.
Jin, Michael; Sanchez, Thomas R; Lamba, Ramit; Fananapazir, Ghaneh; Corwin, Michael T
2017-09-01
The purpose of this article is to determine the accuracy and radiation dose reduction of limited-range CT prescribed from the top of L2 to the top of the pubic symphysis in children with suspected acute appendicitis. We performed a retrospective study of 210 consecutive pediatric patients from December 11, 2012, through December 11, 2014, who underwent abdominopelvic CT for suspected acute appendicitis. Two radiologists independently reviewed the theoretic limited scans from the superior L2 vertebral body to the top of the pubic symphysis, to assess for visualization of the appendix, acute appendicitis, alternative diagnoses, and incidental findings. Separately, the same parameters were assessed on the full scan by the same two reviewers. Whole-body effective doses were determined for the full- and limited-range scans and were compared using the paired t test. The appendix or entire cecum was visualized on the limited scan in all cases, and no cases of acute appendicitis were missed on the simulated limited scan compared with the full scan. Two alternative diagnoses were missed with the limited scan: one case of hydronephrosis and one of acute acalculous cholecystitis. The mean effective dose for the original scan was 5.6 mSv and that for the simulated limited scan was 3.0 mSv, resulting in a dose reduction of 46.4% (p < 0.001). A limited-range CT examination performed from the top of L2 to the top of the pubic symphysis is as accurate as a full-range abdominopelvic CT in evaluating pediatric patients with suspected appendicitis and reduces the dose by approximately 46%.
Geary, Nori
2013-02-01
Analysis of the interactive effects of combinations of hormones or other manipulations with qualitatively similar individual effects is an important topic in basic and clinical endocrinology as well as other branches of basic and clinical research related to integrative physiology. Functional, as opposed to mechanistic, analyses of interactions rely on the concept of synergy, which can be defined qualitatively as a cooperative action or quantitatively as a supra-additive effect according to some metric for the addition of different dose-effect curves. Unfortunately, dose-effect curve addition is far from straightforward; rather, it requires the development of an axiomatic mathematical theory. I review the mathematical soundness, face validity, and utility of the most frequently used approaches to supra-additive synergy. These criteria highlight serious problems in the two most common synergy approaches, response additivity and Loewe additivity, which is the basis of the isobole and related response surface approaches. I conclude that there is no adequate, generally applicable, supra-additive synergy metric appropriate for endocrinology or any other field of basic and clinical integrative physiology. I recommend that these metrics be abandoned in favor of the simpler definition of synergy as a cooperative, i.e., nonantagonistic, effect. This simple definition avoids mathematical difficulties, is easily applicable, meets regulatory requirements for combination therapy development, and suffices to advance phenomenological basic research to mechanistic studies of interactions and clinical combination therapy research.
Medication-related clinical decision support in computerized provider order entry systems: a review.
Kuperman, Gilad J; Bobb, Anne; Payne, Thomas H; Avery, Anthony J; Gandhi, Tejal K; Burns, Gerard; Classen, David C; Bates, David W
2007-01-01
While medications can improve patients' health, the process of prescribing them is complex and error prone, and medication errors cause many preventable injuries. Computer provider order entry (CPOE) with clinical decision support (CDS), can improve patient safety and lower medication-related costs. To realize the medication-related benefits of CDS within CPOE, one must overcome significant challenges. Healthcare organizations implementing CPOE must understand what classes of CDS their CPOE systems can support, assure that clinical knowledge underlying their CDS systems is reasonable, and appropriately represent electronic patient data. These issues often influence to what extent an institution will succeed with its CPOE implementation and achieve its desired goals. Medication-related decision support is probably best introduced into healthcare organizations in two stages, basic and advanced. Basic decision support includes drug-allergy checking, basic dosing guidance, formulary decision support, duplicate therapy checking, and drug-drug interaction checking. Advanced decision support includes dosing support for renal insufficiency and geriatric patients, guidance for medication-related laboratory testing, drug-pregnancy checking, and drug-disease contraindication checking. In this paper, the authors outline some of the challenges associated with both basic and advanced decision support and discuss how those challenges might be addressed. The authors conclude with summary recommendations for delivering effective medication-related clinical decision support addressed to healthcare organizations, application and knowledge base vendors, policy makers, and researchers.
X-ray imaging using digital cameras
NASA Astrophysics Data System (ADS)
Winch, Nicola M.; Edgar, Andrew
2012-03-01
The possibility of using the combination of a computed radiography (storage phosphor) cassette and a semiprofessional grade digital camera for medical or dental radiography is investigated. We compare the performance of (i) a Canon 5D Mk II single lens reflex camera with f1.4 lens and full-frame CMOS array sensor and (ii) a cooled CCD-based camera with a 1/3 frame sensor and the same lens system. Both systems are tested with 240 x 180 mm cassettes which are based on either powdered europium-doped barium fluoride bromide or needle structure europium-doped cesium bromide. The modulation transfer function for both systems has been determined and falls to a value of 0.2 at around 2 lp/mm, and is limited by light scattering of the emitted light from the storage phosphor rather than the optics or sensor pixelation. The modulation transfer function for the CsBr:Eu2+ plate is bimodal, with a high frequency wing which is attributed to the light-guiding behaviour of the needle structure. The detective quantum efficiency has been determined using a radioisotope source and is comparatively low at 0.017 for the CMOS camera and 0.006 for the CCD camera, attributed to the poor light harvesting by the lens. The primary advantages of the method are portability, robustness, digital imaging and low cost; the limitations are the low detective quantum efficiency and hence signal-to-noise ratio for medical doses, and restricted range of plate sizes. Representative images taken with medical doses are shown and illustrate the potential use for portable basic radiography.
Tzonev, Svilen
2018-01-01
Current commercially available digital PCR (dPCR) systems and assays are capable of detecting individual target molecules with considerable reliability. As tests are developed and validated for use on clinical samples, the need to understand and develop robust statistical analysis routines increases. This chapter covers the fundamental processes and limitations of detecting and reporting on single molecule detection. We cover the basics of quantification of targets and sources of imprecision. We describe the basic test concepts: sensitivity, specificity, limit of blank, limit of detection, and limit of quantification in the context of dPCR. We provide basic guidelines how to determine those, how to choose and interpret the operating point, and what factors may influence overall test performance in practice.
Does activity limitation predict discharge destination for postacute care patients?
Chang, Feng-Hang; Ni, Pengsheng; Jette, Alan M
2014-09-01
This study aimed to examine the ability of different domains of activity limitation to predict discharge destination (home vs. nonhome settings) 1 mo after hospital discharge for postacute rehabilitation patients. A secondary analysis was conducted using a data set of 518 adults with neurologic, lower extremity orthopedic, and complex medical conditions followed after discharge from a hospital into postacute care. Variables collected at baseline include activity limitations (basic mobility, daily activity, and applied cognitive function, measured by the Activity Measure for Post-Acute Care), demographics, diagnosis, and cognitive status. The discharge destination was recorded at 1 mo after being discharged from the hospital. Correlational analyses revealed that the 1-mo discharge destination was correlated with two domains of activity (basic mobility and daily activity) and cognitive status. However, multiple logistic regression and receiver operating characteristic curve analyses showed that basic mobility functioning performed the best in discriminating home vs. nonhome living. This study supported the evidence that basic mobility functioning is a critical determinant of discharge home for postacute rehabilitation patients. The Activity Measure for Post-Acute Care-basic mobility showed good usability in discriminating home vs. nonhome living. The findings shed light on the importance of basic mobility functioning in the discharge planning process.
INHALATION EXPOSURE-RESPONSE METHODOLOGY
The Inhalation Exposure-Response Analysis Methodology Document is expected to provide guidance on the development of the basic toxicological foundations for deriving reference values for human health effects, focusing on the hazard identification and dose-response aspects of the ...
Browns Ferry Nuclear Plant radiological impact assessment report, January-June 1988
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, B.E.
1988-01-01
Potential doses to maximum individuals and the population around Browns Ferry are calcuated for each quarter. Measured plant releases for the reporting period are used to estimate these doses. Dispersion of radioactive effluents in the environment is estimated in accordance with the guidance provided and measuring during the period. Using dose calculation methodologies which are described in detail in the Browns Ferry Offsite Dose Calculation Manual, the doses are calculated and used to determine compliance with the dose limits contained in Browns Ferry's Operating License. In this report, the doses resulting from releases are described and compared to quarterly andmore » annual limits established for Browns Ferry.« less
76 FR 79704 - Annual Indexing of Basic Statutory Mortgage Limits for Multifamily Housing Programs
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-22
... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [Docket No. FR-5592-N-01] Annual Indexing of Basic Statutory Mortgage Limits for Multifamily Housing Programs AGENCY: Office of the Assistant Secretary for Housing--Federal Housing Commissioner, HUD. ACTION: Notice. SUMMARY: In accordance with Section 206A of...
76 FR 10387 - Annual Indexing of Basic Statutory Mortgage Limits for Multifamily Housing Programs
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-24
... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [Docket No. FR-5388-N-02] Annual Indexing of Basic Statutory Mortgage Limits for Multifamily Housing Programs AGENCY: Office of the Assistant Secretary for Housing--Federal Housing Commissioner, HUD. ACTION: Notice. SUMMARY: In accordance with Section 206A of...
75 FR 5800 - Annual Indexing of Basic Statutory Mortgage Limits for Multifamily Housing Programs
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-04
... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [Docket No. FR-5388-N-01] Annual Indexing of Basic Statutory Mortgage Limits for Multifamily Housing Programs AGENCY: Office of the Assistant Secretary for Housing--Federal Housing Commissioner, HUD. ACTION: Notice. SUMMARY: In accordance with Section 206A of...
Education for Achieving a New Societal Paradigm.
ERIC Educational Resources Information Center
Hull, Ronald W.
A review of ecological problems facing human society is presented and the relationship of education to social change is considered. Basic environmental limitations which are discussed include population; basic materials such as food, fuels, and water; and environmental tolerance. Ecological hazards which combine with these limitations to result in…
42 CFR 410.12 - Medical and other health services: Basic conditions and limitations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Medical and other health services: Basic conditions and limitations. 410.12 Section 410.12 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS...
Wolff, Jan E.; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika
2015-01-01
The aims of this study were to characterize reinforced metal‐oxide‐semiconductor field‐effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low‐dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50–90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point‐dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k=2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low‐dose limit. The sensitivity was 3.09±0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was −8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD‐comparable low‐dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in vivo measurements (<1.7 mGy) the sensitivity is too low. PACS number: 87.50.wj PMID:26219008
Jibiri, Nnamdi Norbert; Akintunde, Tawakalitu Oluwatoyin; Dambele, Musa Yusuf; Olowookere, Christopher Jimoh
2016-10-05
The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG) and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP) without cannula and with cannula were 10.68 (720.2) and 13.82 (556.4) mSv per week (and per annum), respectively. It was determined that the left hand of the personnel received higher doses than their right hand. The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99mTc-MDP in Nigerian institutions to prevent excessive doses to personnel.
Jibiri, Nnamdi Norbert; Akintunde, Tawakalitu Oluwatoyin; Dambele, Musa Yusuf; Olowookere, Christopher Jimoh
2016-01-01
Objective: The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Methods: Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG) and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. Results: The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP) without cannula and with cannula were 10.68 (720.2) and 13.82 (556.4) mSv per week (and per annum), respectively. It was determined that the left hand of the personnel received higher doses than their right hand. Conclusion: The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99mTc-MDP in Nigerian institutions to prevent excessive doses to personnel. PMID:27751973
Dimitriadis, Alexis; Palmer, Antony L; Thomas, Russell A S; Nisbet, Andrew; Clark, Catharine H
2017-06-01
To adapt and validate an anthropomorphic head phantom for use in a cranial radiosurgery audit. Two bespoke inserts were produced for the phantom: one for providing the target and organ at risk for delineation and the other for performing dose measurements. The inserts were tested to assess their positional accuracy. A basic treatment plan dose verification with an ionization chamber was performed to establish a baseline accuracy for the phantom and beam model. The phantom and inserts were then used to perform dose verification measurements of a radiosurgery plan. The dose was measured with alanine pellets, EBT extended dose film and a plastic scintillation detector (PSD). Both inserts showed reproducible positioning (±0.5 mm) and good positional agreement between them (±0.6 mm). The basic treatment plan measurements showed agreement to the treatment planning system (TPS) within 0.5%. Repeated film measurements showed consistent gamma passing rates with good agreement to the TPS. For 2%-2 mm global gamma, the mean passing rate was 96.7% and the variation in passing rates did not exceed 2.1%. The alanine pellets and PSD showed good agreement with the TPS (-0.1% and 0.3% dose difference in the target) and good agreement with each other (within 1%). The adaptations to the phantom showed acceptable accuracies. The presence of alanine and PSD do not affect film measurements significantly, enabling simultaneous measurements by all three detectors. Advances in knowledge: A novel method for thorough end-to-end test of radiosurgery, with capability to incorporate all steps of the clinical pathway in a time-efficient and reproducible manner, suitable for a national audit.
Factors modifying the response of large animals to low-intensity radiation exposure
NASA Technical Reports Server (NTRS)
Page, N. P.; Still, E. T.
1972-01-01
In assessing the biological response to space radiation, two of the most important modifying factors are dose protraction and dose distribution to the body. Studies are reported in which sheep and swine were used to compare the hematology and lethality response resulting from radiation exposure encountered in a variety of forms, including acute (high dose-rate), chronic (low dose-rate), combinations of acute and chronic, and whether received as a continuous or as fractionated exposure. While sheep and swine are basically similar in response to acute radiation, their sensitivity to chronic irradiation is markedly different. Sheep remain relatively sensitive as the radiation exposure is protracted while swine are more resistant and capable of surviving extremely large doses of chronic irradiation. This response to chronic irradiation correlated well with changes in radiosensitivity and recovery following an acute, sublethal exposure.
Fujibuchi, Toshioh; Murazaki, Hiroo; Kuramoto, Taku; Umedzu, Yoshiyuki; Ishigaki, Yung
2015-08-01
Because of the more advanced and more complex procedures in interventional radiology, longer treatment times have become necessary. Therefore, it is important to determine the exposure doses received by operators and patients. The aim of our study was to evaluate an experimental production wireless dose monitoring system for pulse radiation in diagnostic X-ray. The energy, dose rate, and pulse fluoroscopy dependence were evaluated as the basic characteristics of this system for diagnostic X-ray using a fully digital fluoroscopy system. The error of 1 cm dose equivalent rate was less than 15% from 35.1 keV to 43.2 keV with energy correction using metal filter. It was possible to accurately measure the dose rate dependence of this system, which was highly linear until 100 μSv/h. This system showed a constant response to the pulse fluoroscopy. This system will become useful wireless dosimeter for the individual exposure management by improving the high dose rate and the energy characteristics.
A comparison of quantum limited dose and noise equivalent dose
NASA Astrophysics Data System (ADS)
Job, Isaias D.; Boyce, Sarah J.; Petrillo, Michael J.; Zhou, Kungang
2016-03-01
Quantum-limited-dose (QLD) and noise-equivalent-dose (NED) are performance metrics often used interchangeably. Although the metrics are related, they are not equivalent unless the treatment of electronic noise is carefully considered. These metrics are increasingly important to properly characterize the low-dose performance of flat panel detectors (FPDs). A system can be said to be quantum-limited when the Signal-to-noise-ratio (SNR) is proportional to the square-root of x-ray exposure. Recent experiments utilizing three methods to determine the quantum-limited dose range yielded inconsistent results. To investigate the deviation in results, generalized analytical equations are developed to model the image processing and analysis of each method. We test the generalized expression for both radiographic and fluoroscopic detectors. The resulting analysis shows that total noise content of the images processed by each method are inherently different based on their readout scheme. Finally, it will be shown that the NED is equivalent to the instrumentation-noise-equivalent-exposure (INEE) and furthermore that the NED is derived from the quantum-noise-only method of determining QLD. Future investigations will measure quantum-limited performance of radiographic panels with a modified readout scheme to allow for noise improvements similar to measurements performed with fluoroscopic detectors.
State of the art: dual-energy CT of the abdomen.
Marin, Daniele; Boll, Daniel T; Mileto, Achille; Nelson, Rendon C
2014-05-01
Recent technologic advances in computed tomography (CT)--enabling the nearly simultaneous acquisition of clinical images using two different x-ray energy spectra--have sparked renewed interest in dual-energy CT. By interrogating the unique characteristics of different materials at different x-ray energies, dual-energy CT can be used to provide quantitative information about tissue composition, overcoming the limitations of attenuation-based conventional single-energy CT imaging. In the past few years, intensive research efforts have been devoted to exploiting the unique and powerful opportunities of dual-energy CT for a variety of clinical applications. This has led to CT protocol modifications for radiation dose reduction, improved diagnostic performance for detection and characterization of diseases, as well as image quality optimization. In this review, the authors discuss the basic principles, instrumentation and design, examples of current clinical applications in the abdomen and pelvis, and future opportunities of dual-energy CT.
Talk with Your Doctor about Taking Aspirin Every Day
... En español Talk with Your Doctor about Taking Aspirin to Prevent Disease Browse Sections The Basics Overview ... and Risks What are the benefits of taking aspirin regularly? Low-dose aspirin can reduce your risk ...
Glover, Mark L; Sussmane, Jeffrey B
2002-10-01
To evaluate residents' skills in performing basic mathematical calculations used for prescribing medications to pediatric patients. In 2001, a test of ten questions on basic calculations was given to first-, second-, and third-year residents at Miami Children's Hospital in Florida. Four additional questions were included to obtain the residents' levels of training, specific pediatrics intensive care unit (PICU) experience, and whether or not they routinely double-checked doses and adjusted them for each patient's weight. The test was anonymous and calculators were permitted. The overall score and the score for each resident class were calculated. Twenty-one residents participated. The overall average test score and the mean test score of each resident class was less than 70%. Second-year residents had the highest mean test scores, although there was no significant difference between the classes of residents (p =.745) or relationship between the residents' PICU experiences and their exam scores (p =.766). There was no significant difference between residents' levels of training and whether they double-checked their calculations (p =.633) or considered each patient's weight relative to the dose prescribed (p =.869). Seven residents committed tenfold dosing errors, and one resident committed a 1,000-fold dosing error. Pediatrics residents need to receive additional education in performing the calculations needed to prescribe medications. In addition, residents should be required to demonstrate these necessary mathematical skills before they are allowed to prescribe medications.
10 CFR 835.206 - Limits for the embryo/fetus.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Limits for the embryo/fetus. 835.206 Section 835.206... Exposure § 835.206 Limits for the embryo/fetus. (a) The equivalent dose limit for the embryo/fetus from the... provided in § 835.206(a) shall be avoided. (c) If the equivalent dose to the embryo/fetus is determined to...
10 CFR 835.206 - Limits for the embryo/fetus.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Limits for the embryo/fetus. 835.206 Section 835.206... Exposure § 835.206 Limits for the embryo/fetus. (a) The equivalent dose limit for the embryo/fetus from the... provided in § 835.206(a) shall be avoided. (c) If the equivalent dose to the embryo/fetus is determined to...
10 CFR 835.206 - Limits for the embryo/fetus.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Limits for the embryo/fetus. 835.206 Section 835.206... Exposure § 835.206 Limits for the embryo/fetus. (a) The equivalent dose limit for the embryo/fetus from the... provided in § 835.206(a) shall be avoided. (c) If the equivalent dose to the embryo/fetus is determined to...
10 CFR 835.206 - Limits for the embryo/fetus.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Limits for the embryo/fetus. 835.206 Section 835.206... Exposure § 835.206 Limits for the embryo/fetus. (a) The equivalent dose limit for the embryo/fetus from the... provided in § 835.206(a) shall be avoided. (c) If the equivalent dose to the embryo/fetus is determined to...
10 CFR 835.206 - Limits for the embryo/fetus.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Limits for the embryo/fetus. 835.206 Section 835.206... Exposure § 835.206 Limits for the embryo/fetus. (a) The equivalent dose limit for the embryo/fetus from the... provided in § 835.206(a) shall be avoided. (c) If the equivalent dose to the embryo/fetus is determined to...
A phase I dose escalation study of TTI-237 in patients with advanced malignant solid tumors.
Wang-Gillam, Andrea; Arnold, Susanne M; Bukowski, Ronald M; Rothenberg, Mace L; Cooper, Wendy; Wang, Kenneth K; Gauthier, Eric; Lockhart, A Craig
2012-02-01
This study was to determine the maximum tolerated dose, dose-limiting toxicities, and pharmacokinetic profile of TTI-237, a novel anti-tubulin drug, administered weekly in patients with refractory solid tumors. Using an accelerated dose escalation design, patients with refractory solid tumors were enrolled in this study and treated with TTI-237 intravenously on days 1, 8 and 15 of a 28-day cycle. The starting dose was 4.5 mg/m(2). Pharmacokinetic studies were performed in patients at all dose levels. Twenty-eight patients were enrolled and treated with TTI-237 at dose of 4.5, 9, 15, 22.5 and 31.5 mg/m(2). One dose-limiting toxicity neutropenia fever was observed at 31.5 mg/m(2), and all seven patients developed grade 3 or 4 neutropenia at that dose level. TTI-237 dosage was de-escalated to 22.5 and 18 mg/m(2). Six patients were treated at the 18 mg/m(2) dose level without dose-limiting toxicity prior to trial termination. The mean terminal-phase elimination half-life (t(1/2)) for TTI-237 was 25-29 h, and the mean area under the concentration time curve at 31.5 mg/m(2) was 2,768 ng•h/mL. A protocol defined maximum tolerated dose was not determined because of early termination of the TTI-237 trial by the sponsor. 18 mg/m(2) may be a tolerable dose of TTI-237.
Basic immunology of antibody targeted radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, Jeffrey Y.C.
2006-10-01
Antibody targeted radiotherapy brings an important new treatment modality to Radiation oncology clinic. Radiation dose to tumor and normal tissues are determined by a complex interplay of antibody, antigen, tumor, radionuclide, and host-related factors. A basic understanding of these immunologic and physiologic factors is important to optimally utilize this therapy in the clinic. Preclinical and clinical studies need to be continued to broaden our understanding and to develop new strategies to further improve the efficacy of this promising form of targeted therapy.
Yokoyama, Sumi; Hamada, Nobuyuki; Hayashida, Toshiyuki; Tsujimura, Norio; Tatsuzaki, Hideo; Kurosawa, Tadahiro; Nabatame, Kuniaki; Ohguchi, Hiroyuki; Ohno, Kazuko; Yamauchi-Kawaura, Chiyo; Iimoto, Takeshi; Ichiji, Takeshi; Hotta, Yutaka; Iwai, Satoshi; Akahane, Keiichi
2017-09-25
Since the International Commission on Radiological Protection recommended reducing the occupational equivalent dose limit for the lens of the eye in 2011, there have been extensive discussions in various countries. This paper reviews the current situation in radiation protection of the ocular lens and the discussions on the potential impact of the new lens dose limit in Japan. Topics include historical changes to the lens dose limit, the current situation with occupational lens exposures (e.g., in medical workers, nuclear workers, and Fukushima nuclear power plant workers) and measurements, and the current status of biological studies and epidemiological studies on radiation cataracts. Our focus is on the situation in Japan, but we believe such information sharing will be useful in many other countries.
Effect of Probiotics on Central Nervous System Functions in Animals and Humans: A Systematic Review
Wang, Huiying; Lee, In-Seon; Braun, Christoph; Enck, Paul
2016-01-01
To systematically review the effects of probiotics on central nervous system function in animals and humans, to summarize effective interventions (species of probiotic, dose, duration), and to analyze the possibility of translating preclinical studies. Literature searches were conducted in Pubmed, Medline, Embase, and the Cochrane Library. Only randomized controlled trials were included. In total, 38 studies were included: 25 in animals and 15 in humans (2 studies were conducted in both). Most studies used Bifidobacterium (eg, B. longum, B. breve, and B. infantis) and Lactobacillus (eg, L. helveticus, and L. rhamnosus), with doses between 109 and 1010 colony-forming units for 2 weeks in animals and 4 weeks in humans. These probiotics showed efficacy in improving psychiatric disorder-related behaviors including anxiety, depression, autism spectrum disorder (ASD), obsessive-compulsive disorder, and memory abilities, including spatial and non-spatial memory. Because many of the basic science studies showed some efficacy of probiotics on central nervous system function, this background may guide and promote further preclinical and clinical studies. Translating animal studies to human studies has obvious limitations but also suggests possibilities. Here, we provide several suggestions for the translation of animal studies. More experimental designs with both behavioral and neuroimaging measures in healthy volunteers and patients are needed in the future. PMID:27413138
Effect of Probiotics on Central Nervous System Functions in Animals and Humans: A Systematic Review.
Wang, Huiying; Lee, In-Seon; Braun, Christoph; Enck, Paul
2016-10-30
To systematically review the effects of probiotics on central nervous system function in animals and humans, to summarize effective interventions (species of probiotic, dose, duration), and to analyze the possibility of translating preclinical studies. Literature searches were conducted in Pubmed, Medline, Embase, and the Cochrane Library. Only randomized controlled trials were included. In total, 38 studies were included: 25 in animals and 15 in humans (2 studies were conducted in both). Most studies used Bifidobacterium (eg, B. longum , B. breve , and B. infantis ) and Lactobacillus (eg, L. helveticus , and L. rhamnosus ), with doses between 10⁸ and 10¹⁰ colony-forming units for 2 weeks in animals and 4 weeks in humans. These probiotics showed efficacy in improving psychiatric disorder-related behaviors including anxiety, depression, autism spectrum disorder (ASD), obsessive-compulsive disorder, and memory abilities, including spatial and non-spatial memory. Because many of the basic science studies showed some efficacy of probiotics on central nervous system function, this background may guide and promote further preclinical and clinical studies. Translating animal studies to human studies has obvious limitations but also suggests possibilities. Here, we provide several suggestions for the translation of animal studies. More experimental designs with both behavioral and neuroimaging measures in healthy volunteers and patients are needed in the future.
NASA Astrophysics Data System (ADS)
Galanzha, Ekaterina I.; Tuchin, Valery V.; Chowdhury, Parimal; Zharov, Vladimir P.
2004-08-01
The digital transmission microscopy is very informative, noninvasive for vessels, simple and available method for studying and measuring lymph microvessels function in vivo. Rat mesentery can use as promising animal model of lymph microvessels in vivo. Such imaging system allowed visualizing the entire lymphangion (with input and output valves), its wall, lymphatic valves, lymph flow as well as single cells in flow; obtaining anew basic information on lymph microcirculation and quantitative data on lymphatic function including indexes of phasic contractions and valve function, the quantitative parameters of lymph-flow velocity. Rat mesentery is good model to create different types of lymphedemas in acute and chronic experiments. The obtained data revealed that significant edema started immediately after lymph node dissection in one-half of cases and was accompanied by lymphatic disturbances. The greatest degree of edema was found after 1 week. After 4 weeks, the degree of edema sometimes decreased, but functional lymphatic disturbances progressed. Nicotine had significant direct dose-dependent effect on microlymphatic function at the acute local application, but the same dose of this drug was not effect on microcirculation in chronic intoxication. Despite yielding interesting data, transmittance microscopy had some limitations when applied to microcirculation studies. The problems could be solved at the application of integrated measuring technique.
Gao, Li; Wei, Yinmao
2016-08-01
A novel mixed-mode adsorbent was prepared by functionalizing silica with tris(2-aminoethyl)amine and 3-phenoxybenzaldehyde as the main mixed-mode scaffold due to the presence of the plentiful amino groups and benzene rings in their molecules. The adsorption mechanism was probed with acidic, natural and basic compounds, and the mixed hydrophobic and ion-exchange interactions were found to be responsible for the adsorption of analytes. The suitability of dispersive solid-phase extraction was demonstrated in the determination of chlorophenols in environmental water. Several parameters, including sample pH, desorption solvent, ionic strength, adsorbent dose, and extraction time were optimized. Under the optimal extraction conditions, the proposed dispersive solid-phase extraction coupled with high-performance liquid chromatography showed good linearity range and acceptable limits of detection (0.22∽0.54 ng/mL) for five chlorophenols. Notably, the higher extraction recoveries (88.7∽109.7%) for five chlorophenols were obtained with smaller adsorbent dose (10 mg) and shorter extraction time (15 min) compared with the reported methods. The proposed method might be potentially applied in the determination of trace chlorophenols in real water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The need for innovative strategies to improve immunisation services in rural Zimbabwe.
Chadambuka, Addmore; Chimusoro, Anderson; Apollo, Tsitsilina; Tshimanga, Mufuta; Namusisi, Olivia; Luman, Elizabeth T
2012-01-01
Gokwe South, a rural district in Midlands Province, Zimbabwe, reported the lowest rate of immunisation coverage in the country in 2005: 55 per cent of children vaccinated with three doses of diphtheria/pertussis/tetanus vaccine (DPT3) and 35 per cent dropout between the first and third dose of DPT. In January 2007, the authors assessed local barriers to immunisation and proposed strategies to improve immunisation rates in the district, in the face of nationwide economic and political challenges. A situational analysis was performed to assess barriers to immunisation using focus-group discussions with health workers, key informant interviews with health management and community leaders, and desk reviews of records. Responses were categorised and solutions proposed. Health workers and key informants reported that immunisation service delivery was hampered by insufficient availability of gas for cold-chain equipment, limited transport and fuel to conduct basic activities, and inadequate staff and supervision. Improving coverage will require prioritising gas for vaccine cold-chain equipment, identifying reliable transportation or alternative transportation solutions, and increased staff, training and supervision. Local assessment is critical to pinpointing site-specific barriers, and innovative strategies are needed to overcome existing contextual challenges. © 2012 The Author(s). Disasters © Overseas Development Institute, 2012.
Key Performance Indicators in the Evaluation of the Quality of Radiation Safety Programs.
Schultz, Cheryl Culver; Shaffer, Sheila; Fink-Bennett, Darlene; Winokur, Kay
2016-08-01
Beaumont is a multiple hospital health care system with a centralized radiation safety department. The health system operates under a broad scope Nuclear Regulatory Commission license but also maintains several other limited use NRC licenses in off-site facilities and clinics. The hospital-based program is expansive including diagnostic radiology and nuclear medicine (molecular imaging), interventional radiology, a comprehensive cardiovascular program, multiple forms of radiation therapy (low dose rate brachytherapy, high dose rate brachytherapy, external beam radiotherapy, and gamma knife), and the Research Institute (including basic bench top, human and animal). Each year, in the annual report, data is analyzed and then tracked and trended. While any summary report will, by nature, include items such as the number of pieces of equipment, inspections performed, staff monitored and educated and other similar parameters, not all include an objective review of the quality and effectiveness of the program. Through objective numerical data Beaumont adopted seven key performance indicators. The assertion made is that key performance indicators can be used to establish benchmarks for evaluation and comparison of the effectiveness and quality of radiation safety programs. Based on over a decade of data collection, and adoption of key performance indicators, this paper demonstrates one way to establish objective benchmarking for radiation safety programs in the health care environment.
An NMR relaxometry and gravimetric study of gelatin-free aqueous polyacrylamide dosimeters
NASA Astrophysics Data System (ADS)
Babic, Steven; Schreiner, L. John
2006-09-01
In conformal radiation therapy, a high dose of radiation is given to a target volume to increase the probability of cure, and care is taken to minimize the dose to surrounding healthy tissue. The techniques used to achieve this are very complicated and the precise verification of the resulting three-dimensional (3D) dose distribution is required. Polyacrylamide gelatin (PAG) dosimeters with magnetic resonance imaging and optical computed tomography scanning provide the required 3D dosimetry with high spatial resolution. Many basic studies have characterized these chemical dosimeters that polymerize under irradiation. However, the investigation of the fundamental properties of the radiation-induced polymerization in PAG dosimeters is complicated by the presence of the background gelatin matrix. In this work, a gelatin-free model system for the study of the basic radiation-induced polymerization in PAG dosimeters has been developed. Experiments were performed on gelatin-free dosimeters, named aqueous polyacrylamide (APA) dosimeters, containing equal amounts of acrylamide and N,N'-methylene-bisacrylamide. The APA dosimeters were prepared with four different total monomer concentrations (2, 4, 6 and 8% by weight). Nuclear magnetic resonance (NMR) spin-spin and spin-lattice proton relaxation measurements at 20 MHz, and gravimetric analyses performed on all four dosimeters, show a continuous degree of polymerization over the dose range of 0-25 Gy. The developed NMR model explains the relationship observed between the relaxation data and the amount of crosslinked polymer formed at each dose. This model can be extended with gelatin relaxation data to provide a fundamental understanding of radiation-induced polymerization in the conventional PAG dosimeters.
An NMR relaxometry and gravimetric study of gelatin-free aqueous polyacrylamide dosimeters.
Babic, Steven; Schreiner, L John
2006-09-07
In conformal radiation therapy, a high dose of radiation is given to a target volume to increase the probability of cure, and care is taken to minimize the dose to surrounding healthy tissue. The techniques used to achieve this are very complicated and the precise verification of the resulting three-dimensional (3D) dose distribution is required. Polyacrylamide gelatin (PAG) dosimeters with magnetic resonance imaging and optical computed tomography scanning provide the required 3D dosimetry with high spatial resolution. Many basic studies have characterized these chemical dosimeters that polymerize under irradiation. However, the investigation of the fundamental properties of the radiation-induced polymerization in PAG dosimeters is complicated by the presence of the background gelatin matrix. In this work, a gelatin-free model system for the study of the basic radiation-induced polymerization in PAG dosimeters has been developed. Experiments were performed on gelatin-free dosimeters, named aqueous polyacrylamide (APA) dosimeters, containing equal amounts of acrylamide and N,N'-methylene-bisacrylamide. The APA dosimeters were prepared with four different total monomer concentrations (2, 4, 6 and 8% by weight). Nuclear magnetic resonance (NMR) spin-spin and spin-lattice proton relaxation measurements at 20 MHz, and gravimetric analyses performed on all four dosimeters, show a continuous degree of polymerization over the dose range of 0-25 Gy. The developed NMR model explains the relationship observed between the relaxation data and the amount of crosslinked polymer formed at each dose. This model can be extended with gelatin relaxation data to provide a fundamental understanding of radiation-induced polymerization in the conventional PAG dosimeters.
Hachiya, Misao; Akashi, Makoto
2016-09-01
A huge earthquake struck the northeast coast of the main island of Japan on 11 March 2011 triggering an extremely large tsunami to hit the area. The earthquake and tsunami caused serious damage to the Fukushima nuclear power plants (NPPs) of Tokyo Electric Power Company (TEPCO), resulting in large amounts of radioactive materials being released into the environment. The major nuclides released were (131)I, (134)Cs and (137)Cs. The deposition of these radioactive materials on land resulted in a high ambient dose of radiation around the NPPs, especially within a 20-km radius. Dose assessments based on behavior survey and ambient dose rates revealed that external doses to most residents were lower than 5 mSv, with the maximum dose being 25 mSv. It was fortunate that no workers from the NPPs required treatment from the viewpoint of deterministic effects of radiation. However, a lack of exact knowledge of radiation and its effects prevented the system for medical care and transportation of contaminated personnel from functioning. After the accident, demands or requests for training courses have been increasing. We have learned from the response to this disaster that basic knowledge of radiation and its effects is extremely important for not only professionals such as health care providers but also for other professionals including teachers. © World Health Organisation 2016. All rights reserved. The World Health Organization has granted Oxford University Press permission for the reproduction of this article.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamashita, Hideomi; Nakagawa, Keiichi; Nakamura, Naoki
2006-12-01
Purpose: Taste loss is a major cause of morbidity in patients undergoing head-and-neck irradiation. The relationship between the time course and the degree of taste disorder was studied in both acute and late phases. Methods and Materials: Taste ability was measured by the taste threshold for the four basic tastes using a filter paper disc method in patients before, during, and after radiotherapy. The subjects were divided into two groups. In Group A, Radiation fields included most of the tongue (n = 100), and in Group B Radiation fields did not include the tip of the tongue (n = 18).more » Results: In Group A, there was a significant impairment of the threshold of all four basic tastes at 3 weeks after starting radiotherapy (RT), and this impairment remained at 8 weeks (p < 0.05). This was not seen in Group B. In Group A, there was no significant difference in the patterns of taste sensitivity change between the high-dose (>20 Gy) and low-dose ({<=}20 Gy) groups. In the late phase, recovery of taste loss was seen in both groups since 4 months after completing RT. Conclusions: Unless the anterior part of the tongue was irradiated, taste loss was not observed during RT. When the anterior part of the tongue was irradiated, a difference by radiation dose was not observed in the taste loss pattern. Additionally, radiation-induced taste dysfunction appears to be a temporal effect.« less
Toxicology of dimethyl and monomethyl derivatives of acetamide and formamide: a second update.
Kennedy, Gerald L
2012-11-01
Dimethylacetamide (DMAC) and dimethylformamide (DMF) continue to be important, widely used solvents involved in a wide variety of industrial applications. As liquids with relatively low vapor pressures, contact with both the integumentary and respiratory systems is the main source of human exposure. Although airborne control levels for the workplace have been established and industrial hygiene practices to limit dermal contact have been put in place, use of these chemicals has been associated with occupational illness, mainly in Asia where new and expanded uses have led to overexposures. Thus an update of the basic toxicology data including tables indicating the dose/exposure response characteristics of both DMAC and DMF is currently important. Both chemicals are similar from a toxicology perspective. Human experience has generally shown the materials to be without adverse effect except under conditions where airborne and dermal controls were not properly applied. The use of urinary metabolite monitoring has successfully been employed to measure integrated dermal and inhalation worker exposure. The chemicals are not particularly toxic following acute exposure but high doses can produce damage to the liver, the organ which is first affected by these two chemicals. Repeated dose/exposure studies have characterized both the targets of toxicity and the doses required to produce changes by various routes of exposure. Higher doses of these materials can produce changes in developing systems, infrequently in experiments at doses in which the maternal animal is unaffected, thus care needs to be taken when exposures are to women of child-bearing age. The chemicals appear to be low in genetic activity and inhalation exposures have not shown the materials to produce tumors in rodents except with DMF in a situation in which aerosol formation was encountered. This presentation extends the two previous reviews and, like those, includes updated information on acetamide and formamide and their monomethyl derivatives as well as the commercially important DMAC and DMF. Since a large portion of the newer information deals with effects in humans and biomonitoring, these sections are presented at the start of this review.
Radiation-Hardened Circuitry Using Mask-Programmable Analog Arrays. Report 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Britton, Jr, Charles L.; Shelton, Jacob H.; Ericson, Milton Nance
As the recent accident at Fukushima Daiichi so vividly demonstrated, telerobotic technologies capable of withstanding high radiation environments need to be readily available to enable operations, repair, and recovery under severe accident scenarios when human entry is extremely dangerous or not possible. Telerobotic technologies that enable remote operation in high dose rate environments have undergone revolutionary improvement over the past few decades. However, much of this technology cannot be employed in nuclear power environments because of the radiation sensitivity of the electronics and the organic insulator materials currently in use. This is a report of the activities involving Task 3more » of the Nuclear Energy Enabling Technologies (NEET) 2 project Radiation Hardened Circuitry Using Mask-Programmable Analog Arrays [1]. Evaluation of the performance of the system for both pre- and post-irradiation as well as operation at elevated temperature will be performed. Detailed performance of the system will be documented to ensure the design meets requirements prior to any extended evaluation. A suite of tests will be developed which will allow evaluation before and after irradiation and during temperature. Selection of the radiation exposure facilities will be determined in the early phase of the project. Radiation exposure will consist of total integrated dose (TID) up to 200 kRad or above with several intermediate doses during test. Dose rates will be in various ranges determined by the facility that will be used with a target of 30 kRad/hr. Many samples of the pre-commercial devices to be used will have been tested in previous projects to doses of at least 300 kRad and temperatures up to 125C. The complete systems will therefore be tested for performance at intermediate doses. Extended temperature testing will be performed up to the limit of the commercial sensors. The test suite performed at each test point will consist of operational testing of the three basic measurement functions plus electronic functional testing (power dissipation, voltage offset changes, noise variations, etc.). This suite will be developed as part of this task.« less
Effect of Varient Dosages of Amphetamine Upon Endurance
ERIC Educational Resources Information Center
Williams, Melvin H.; Thompson, John
1973-01-01
This study sought to provide basic information concerning the acute effects of a small, moderate, and large dose of d-amphetamine sulfate upon muscular endurance; a secondary purpose involved the effect upon submaximal and maximal heart rate. (Author/JA)
Radiation 101: Effects on Hardware and Robotic Systems
NASA Technical Reports Server (NTRS)
Pellish, Jonathan A.
2015-01-01
We present basic information on different types of radiation effects, including total ionizing dose, displacement damage, and single-event effects. The content is designed to educate space weather professionals, space operations professionals, and other science and engineering stakeholders.
Dixit, Fuhar; Barbeau, Benoit; Mohseni, Madjid
2018-08-01
Microcystins are the most commonly occurring cyanotoxins, and have been extensively studied across the globe. In the present study, a strongly basic anion exchange resin was employed to investigate the removal of Microcystin-LR (MCLR), one of the most toxic microcystin variants. Factors influencing the uptake behavior included the MCLR and resin concentrations, resin dosage, and natural organic matter (NOM) characteristics, specifically, the charge density and molecular weight distribution of source water NOM. Equivalent background concentration (EBC) was employed to evaluate the competitive uptake between NOM and MCLR. The experimental data were compared with different mathematical and physical models and pore diffusion was determined as the rate-limiting step. The resin dose/solute concentration ratio played a key role in the MCLR uptake process and MCLR removal was attributed primarily to electrostatic attractions. Charge density and molecular weight distribution of the background NOM fractions played a major role in MCLR removal at lower resin dosages (200 mg/L ∼ 1 mL/L and below), where a competitive uptake was observed due to the limited exchange sites. Further, evidences of pore blockage and site reduction were also observed in the presence of humics and larger molecular weight organic fractions, where a four-fold reduction in the MCLR uptake was observed. Comparable results were obtained for laboratory studies on synthetic laboratory water and surface water under similar conditions. Given their excellent performance and low cost, anion exchange resins are expected to present promising potentials for applications involving the removal of removal of algal toxins and NOM from surface waters. Copyright © 2018 Elsevier Ltd. All rights reserved.
Evaluation of human exposure to single electromagnetic pulses of arbitrary shape.
Jelínek, Lukás; Pekárek, Ludĕk
2006-03-01
Transient current density J(t) induced in the body of a person exposed to a single magnetic pulse of arbitrary shape or to a magnetic jump is filtered by a convolution integral containing in its kernel the frequency and phase dependence of the basic limit value adopted in a way similar to that used for reference values in the International Commission on Non-lonising Radiation Protection statement. From the obtained time-dependent dimensionless impact function W(J)(t) can immediately be determined whether the exposure to the analysed single event complies with the basic limit. For very slowly varying field, the integral kernel is extended to include the softened ICNIRP basic limit for frequencies lower than 4 Hz.
Varlamova, A I; Arkhipov, I A; Odoevskaia, I M; Danilevskaia, N V; Khalikov, S S; Chistiachenko, Iu S; Dushkin, A V
2014-01-01
The efficacy of a new fenbendazile formulation produced by nanotechnology-based drug delivery system was investigated in45 sheep naturally infected with gastrointestinal nematodes. The formulation showed 95.6% efficacy against Nematodes spp. at a dose of 1.0 mg/kg dw of its active ingredient and 100% efficacy against other species of gastrointestinal nematodes. Given at a dose of 10 mg/kg dw, the basic drug--fenbendazole (substance) displayed 96.39 and 100% efficacy, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayo, Charles, E-mail: charles.mayo@umassmemorial.or; Yorke, Ellen; Merchant, Thomas E.
Publications relating brainstem radiation toxicity to quantitative dose and dose-volume measures derived from three-dimensional treatment planning were reviewed. Despite the clinical importance of brainstem toxicity, most studies reporting brainstem effects after irradiation have fewer than 100 patients. There is limited evidence relating toxicity to small volumes receiving doses above 60-64 Gy using conventional fractionation and no definitive criteria regarding more subtle dose-volume effects or effects after hypofractionated treatment. On the basis of the available data, the entire brainstem may be treated to 54 Gy using conventional fractionation using photons with limited risk of severe or permanent neurological effects. Smaller volumesmore » of the brainstem (1-10 mL) may be irradiated to maximum doses of 59 Gy for dose fractions <=2 Gy; however, the risk appears to increase markedly at doses >64 Gy.« less
Figueroa, Isabel; Leipold, Doug; Leong, Steve; Zheng, Bing; Triguero-Carrasco, Montserrat; Fourie-O'Donohue, Aimee; Kozak, Katherine R; Xu, Keyang; Schutten, Melissa; Wang, Hong; Polson, Andrew G; Kamath, Amrita V
2018-05-14
For antibody-drug conjugates (ADCs) that carry a cytotoxic drug, doses that can be administered in preclinical studies are typically limited by tolerability, leading to a narrow dose range that can be tested. For molecules with non-linear pharmacokinetics (PK), this limited dose range may be insufficient to fully characterize the PK of the ADC and limits translation to humans. Mathematical PK models are frequently used for molecule selection during preclinical drug development and for translational predictions to guide clinical study design. Here, we present a practical approach that uses limited PK and receptor occupancy (RO) data of the corresponding unconjugated antibody to predict ADC PK when conjugation does not alter the non-specific clearance or the antibody-target interaction. We used a 2-compartment model incorporating non-specific and specific (target mediated) clearances, where the latter is a function of RO, to describe the PK of anti-CD33 ADC with dose-limiting neutropenia in cynomolgus monkeys. We tested our model by comparing PK predictions based on the unconjugated antibody to observed ADC PK data that was not utilized for model development. Prospective prediction of human PK was performed by incorporating in vitro binding affinity differences between species for varying levels of CD33 target expression. Additionally, this approach was used to predict human PK of other previously tested anti-CD33 molecules with published clinical data. The findings showed that, for a cytotoxic ADC with non-linear PK and limited preclinical PK data, incorporating RO in the PK model and using data from the corresponding unconjugated antibody at higher doses allowed the identification of parameters to characterize monkey PK and enabled human PK predictions.
Temporal analysis of the October 1989 proton flare using computerized anatomical models
NASA Technical Reports Server (NTRS)
Simonsen, L. C.; Cucinotta, F. A.; Atwell, W.; Nealy, J. E.
1993-01-01
The GOES-7 time history data of hourly averaged integral proton fluxes at various particle kinetic energies are analyzed for the solar proton event that occurred between October 19 and 29, 1989. By analyzing the time history data, the dose rates which may vary over many orders of magnitude in the early phases of the flare can be estimated as well as the cumulative dose as a function of time. Basic transport calculations are coupled with detailed body organ thickness distributions from computerized anatomical models to estimate dose rates and cumulative doses to 20 critical body organs. For a 5-cm-thick water shield, cumulative skin, eye, and blood-forming-organ dose equivalents of 1.27, 1.23, and 0.41 Sv, respectively, are estimated. These results are approximately 40-50 percent less than the widely used 0- and 5-cm slab dose estimates. The risk of cancer incidence and mortality are also estimated for astronauts protected by various water shield thicknesses.
Chandawarkar, Rajiv Y; Wagh, Mihir S; Kovalchin, Joseph T; Srivastava, Pramod
2004-04-01
Immunization with heat-shock protein (HSP) gp96 elicits protective immunity to the cancer or virus-infected cells from which it is derived. Low doses of gp96 generate immunity, while doses 10 times the immunizing dose do not. We show here that injection of high doses of gp96 generates CD4(+) T cells that down-regulate a variety of ongoing immune responses. Immunization with high doses of gp96 prevents myelin basic protein- or proteolipid protein-induced autoimmune encephalomyelitis in SJL mice and the onset of diabetes in non-obese diabetic mice. The suppression of immune response can be adoptively transferred with CD4(+) cells and does not partition with the CD25 phenotype. The immunomodulatory properties of gp96 (and possibly other HSP) may be used for antigen-specific activation or suppression of cellular immune responses. The latter may form the basis for novel immunotherapies for autoimmune diseases.
Physics must join with biology in better assessing risk from low-dose irradiation.
Feinendegen, L E; Neumann, R D
2005-01-01
This review summarises the complex response of mammalian cells and tissues to low doses of ionising radiation. This thesis encompasses induction of DNA damage, and adaptive protection against both renewed damage and against propagation of damage from the basic level of biological organisation to the clinical expression of detriment. The induction of DNA damage at low radiation doses apparently is proportional to absorbed dose at the physical/chemical level. However, any propagation of such damage to higher levels of biological organisation inherently follows a sigmoid function. Moreover, low-dose-induced inhibition of damage propagation is not linear, but instead follows a dose-effect function typical for adaptive protection, after an initial rapid rise it disappears at doses higher than approximately 0.1-0.2 Gy to cells. The particular biological response duality at low radiation doses precludes the validity of the linear-no-threshold hypothesis in the attempt to relate absorbed dose to cancer. In fact, theory and observation support not only a lower cancer incidence than expected from the linear-no-threshold hypothesis, but also a reduction of spontaneously occurring cancer, a hormetic response, in the healthy individual.
EMP Attachment 3 DOE-SC PNNL Site Dose Assessment Guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.
2011-12-21
This Dose Assessment Guidance (DAG) describes methods to use to determine the Maximally-Exposed Individual (MEI) location and to estimate dose impact to that individual under the U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest National Laboratory (PNNL) Site Environmental Monitoring Plan (EMP). This guidance applies to public dose from radioactive material releases to the air from PNNL Site operations. This document is an attachment to the Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP) and describes dose assessment guidance for radiological air emissions. The impact of radiological air emissions from the U.S. Department of Energy Office ofmore » Science (DOE-SC) PNNL Site is indicated by dose estimates to a maximally exposed member of the public, referred to as the maximally exposed individual (MEI). Reporting requirements associated with dose to members of the public from radiological air emissions are in 40 CFR Part 61.94, WAC 246-247-080, and DOE Order 458.1. The DOE Order and state standards for dose from radioactive air emissions are consistent with U.S. Environmental Protection Agency (EPA) dose standards in 40 CFR 61.92 (i.e., 10 mrem/yr to a MEI). Despite the fact that the current Contract Requirements Document (CRD) for the DOE-SC PNNL Site operations does not include the requirement to meet DOE CRD 458.1, paragraph 2.b, public dose limits, the DOE dose limits would be met when EPA limits are met.« less
Elsholtz, Fabian Henry Jürgen; Kamp, Julia Evi-Katrin; Vahldiek, Janis Lucas; Hamm, Bernd; Niehues, Stefan Markus
2018-06-18
CT-guided periradicular infiltration of the cervical spine is an effective symptomatic treatment in patients with radiculopathy-associated pain syndromes. This study evaluates the robustness and safety of a low-dose protocol on a CT scanner with iterative reconstruction software. A total of 183 patients who underwent periradicular infiltration therapy of the cervical spine were included in this study. 82 interventions were performed on a new CT scanner with a new intervention protocol using an iterative reconstruction algorithm. Spot scanning was implemented for planning and a basic low-dose setup of 80 kVp and 5 mAs was established during intermittent fluoroscopy. The comparison group included 101 prior interventions on a scanner without iterative reconstruction. The dose-length product (DLP), number of acquisitions, pain reduction on a numeric analog scale, and protocol changes to achieve a safe intervention were recorded. The median DLP for the whole intervention was 24.3 mGy*cm in the comparison group and 1.8 mGy*cm in the study group. The median pain reduction was -3 in the study group and -2 in the comparison group. A 5 mAs increase in the tube current-time product was required in 5 patients of the study group. Implementation of a new scanner and intervention protocol resulted in a 92.6 % dose reduction without a compromise in safety and pain relief. The dose needed here is more than 75 % lower than doses used for similar interventions in published studies. An increase of the tube current-time product was needed in only 6 % of interventions. · The presented ultra-low-dose protocol allows for a significant dose reduction without compromising outcome.. · The protocol includes spot scanning for planning purposes and a basic setup of 80 kVp and 5 mAs.. · The iterative reconstruction algorithm is activated during fluoroscopy.. · Elsholtz FH, Kamp JE, Vahldiek JL et al. Periradicular Infiltration of the Cervical Spine: How New CT Scanner Techniques and Protocol Modifications Contribute to the Achievement of Low-Dose Interventions. Fortschr Röntgenstr 2018; DOI: 10.1055/a-0632-3930. © Georg Thieme Verlag KG Stuttgart · New York.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saw, Cheng B., E-mail: cheng.saw@aol.com; Battin, Frank; McKeague, Janice
2016-01-01
Dose or treatment planning management is necessary for the re-irradiation of intracranial relapses after focal irradiation, radiosurgery, or stereotactic radiotherapy. The current clinical guidelines for metastatic brain tumors are the use of focal irradiation if the patient presents with 4 lesions or less. Salvage treatments with the use of whole brain radiation therapy (WBRT) can then be used to limit disease progression if there is an intracranial relapse. However, salvage WBRT poses a number of challenges in dose planning to limit disease progression and preserve neurocognitive function. This work presents the dose planning management that addresses a method of delineatingmore » previously treated volumes, dose level matching, and the dose delivery techniques for WBRT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Reid F.; Zhai, Huifang; Both, Stefan
Purpose: Uncontrolled local growth is the cause of death in ∼30% of patients with unresectable pancreatic cancers. The addition of standard-dose radiotherapy to gemcitabine has been shown to confer a modest survival benefit in this population. Radiation dose escalation with three-dimensional planning is not feasible, but high-dose intensity-modulated radiation therapy (IMRT) has been shown to improve local control. Still, dose-escalation remains limited by gastrointestinal toxicity. In this study, the authors investigate the potential use of double scattering (DS) and pencil beam scanning (PBS) proton therapy in limiting dose to critical organs at risk. Methods: The authors compared DS, PBS, andmore » IMRT plans in 13 patients with unresectable cancer of the pancreatic head, paying particular attention to duodenum, small intestine, stomach, liver, kidney, and cord constraints in addition to target volume coverage. All plans were calculated to 5500 cGy in 25 fractions with equivalent constraints and normalized to prescription dose. All statistics were by two-tailed paired t-test. Results: Both DS and PBS decreased stomach, duodenum, and small bowel dose in low-dose regions compared to IMRT (p < 0.01). However, protons yielded increased doses in the mid to high dose regions (e.g., 23.6–53.8 and 34.9–52.4 Gy for duodenum using DS and PBS, respectively; p < 0.05). Protons also increased generalized equivalent uniform dose to duodenum and stomach, however these differences were small (<5% and 10%, respectively; p < 0.01). Doses to other organs-at-risk were within institutional constraints and placed no obvious limitations on treatment planning. Conclusions: Proton therapy does not appear to reduce OAR volumes receiving high dose. Protons are able to reduce the treated volume receiving low-intermediate doses, however the clinical significance of this remains to be determined in future investigations.« less
TH-E-202-01: Pitfalls and Remedies in PET/CT Imaging for RT Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pan, T.
2016-06-15
PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy.more » The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the basics of using FDG PET/CT for tumor response evaluation. Learn about recent advancement in PET/CT radiomics and non-FDG PET tracers for response assessment. This work was supported in part by the National Cancer Institute Grants R01CA172638.; W. Lu, This work was supported in part by the National Cancer Institute Grants R01CA172638.« less
20 CFR 220.102 - Non-severe impairment(s), defined.
Code of Federal Regulations, 2010 CFR
2010-04-01
... significantly limit the claimant's physical or mental ability to do basic work activities. (b) Basic work activities. Basic work activities means the ability and aptitudes necessary to do most jobs. Examples of these include— (1) Physical functions such as walking, standing, sitting, lifting, pushing, pulling...
Testing of the analytical anisotropic algorithm for photon dose calculation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Esch, Ann van; Tillikainen, Laura; Pyykkonen, Jukka
2006-11-15
The analytical anisotropic algorithm (AAA) was implemented in the Eclipse (Varian Medical Systems) treatment planning system to replace the single pencil beam (SPB) algorithm for the calculation of dose distributions for photon beams. AAA was developed to improve the dose calculation accuracy, especially in heterogeneous media. The total dose deposition is calculated as the superposition of the dose deposited by two photon sources (primary and secondary) and by an electron contamination source. The photon dose is calculated as a three-dimensional convolution of Monte-Carlo precalculated scatter kernels, scaled according to the electron density matrix. For the configuration of AAA, an optimizationmore » algorithm determines the parameters characterizing the multiple source model by optimizing the agreement between the calculated and measured depth dose curves and profiles for the basic beam data. We have combined the acceptance tests obtained in three different departments for 6, 15, and 18 MV photon beams. The accuracy of AAA was tested for different field sizes (symmetric and asymmetric) for open fields, wedged fields, and static and dynamic multileaf collimation fields. Depth dose behavior at different source-to-phantom distances was investigated. Measurements were performed on homogeneous, water equivalent phantoms, on simple phantoms containing cork inhomogeneities, and on the thorax of an anthropomorphic phantom. Comparisons were made among measurements, AAA, and SPB calculations. The optimization procedure for the configuration of the algorithm was successful in reproducing the basic beam data with an overall accuracy of 3%, 1 mm in the build-up region, and 1%, 1 mm elsewhere. Testing of the algorithm in more clinical setups showed comparable results for depth dose curves, profiles, and monitor units of symmetric open and wedged beams below d{sub max}. The electron contamination model was found to be suboptimal to model the dose around d{sub max}, especially for physical wedges at smaller source to phantom distances. For the asymmetric field verification, absolute dose difference of up to 4% were observed for the most extreme asymmetries. Compared to the SPB, the penumbra modeling is considerably improved (1%, 1 mm). At the interface between solid water and cork, profiles show a better agreement with AAA. Depth dose curves in the cork are substantially better with AAA than with SPB. Improvements are more pronounced for 18 MV than for 6 MV. Point dose measurements in the thoracic phantom are mostly within 5%. In general, we can conclude that, compared to SPB, AAA improves the accuracy of dose calculations. Particular progress was made with respect to the penumbra and low dose regions. In heterogeneous materials, improvements are substantial and more pronounced for high (18 MV) than for low (6 MV) energies.« less
Optimized Varian aSi portal dosimetry: development of datasets for collective use.
Van Esch, Ann; Huyskens, Dominique P; Hirschi, Lukas; Baltes, Christof
2013-11-04
Although much literature has been devoted to portal dosimetry with the Varian amorphous silicon (aSi) portal imager, the majority of the described methods are not routinely adopted because implementation procedures are cumbersome and not within easy reach of most radiotherapy centers. To make improved portal dosimetry solutions more generally available, we have investigated the possibility of converting optimized configurations into ready-to-use standardized datasets. Firstly, for all commonly used photon energies (6, 10, 15, 18, and 20 MV), basic beam data acquired on 20 aSi panels were used to assess the interpanel reproducibility. Secondly, a standardized portal dose image prediction (PDIP) algorithm configuration was created for every energy, using a three-step process to optimize the aSi dose response function and profile correction files for the dosimetric calibration of the imager panel. An approximate correction of the backscatter of the Exact arm was also incorporated. Thirdly, a set of validation fields was assembled to assess the accuracy of the standardized configuration. Variations in the basic beam data measured on different aSi panels very rarely exceeded 2% (2 mm) and are of the same order of magnitude as variations between different Clinacs when measuring in reference conditions in water. All studied aSi panels can hence be regarded as nearly identical. Standardized datasets were successfully created and implemented. The test package proved useful in highlighting possible problems and illustrating remaining limitations, but also in demonstrating the good overall results (95% pass rate for 3%,3 mm) that can be obtained. The dosimetric behavior of all tested aSi panels was found to be nearly identical for all tested energies. The approach of using standardized datasets was then successfully tested through the creation and evaluation of PDIP preconfigured datasets that can be used within the Varian portal dosimetry solution.
ERIC Educational Resources Information Center
McConnell, Beverly B.
Begun in 1980 with 358 students, the Yakima (Washington) Public Schools' Basic Education for Limited English Proficient Students (BELEPS) Program served 1,250 grade K-12 students (94% Hispanic) in 1985. Its four programs were based on the degree of the students' English proficiency, and taught (1) reading only in Spanish, (2) reading in Spanish…
A dose-response curve for biodosimetry from a 6 MV electron linear accelerator
Lemos-Pinto, M.M.P.; Cadena, M.; Santos, N.; Fernandes, T.S.; Borges, E.; Amaral, A.
2015-01-01
Biological dosimetry (biodosimetry) is based on the investigation of radiation-induced biological effects (biomarkers), mainly dicentric chromosomes, in order to correlate them with radiation dose. To interpret the dicentric score in terms of absorbed dose, a calibration curve is needed. Each curve should be constructed with respect to basic physical parameters, such as the type of ionizing radiation characterized by low or high linear energy transfer (LET) and dose rate. This study was designed to obtain dose calibration curves by scoring of dicentric chromosomes in peripheral blood lymphocytes irradiated in vitro with a 6 MV electron linear accelerator (Mevatron M, Siemens, USA). Two software programs, CABAS (Chromosomal Aberration Calculation Software) and Dose Estimate, were used to generate the curve. The two software programs are discussed; the results obtained were compared with each other and with other published low LET radiation curves. Both software programs resulted in identical linear and quadratic terms for the curve presented here, which was in good agreement with published curves for similar radiation quality and dose rates. PMID:26445334
TU-D-201-05: Validation of Treatment Planning Dose Calculations: Experience Working with MPPG 5.a
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xue, J; Park, J; Kim, L
2016-06-15
Purpose: Newly published medical physics practice guideline (MPPG 5.a.) has set the minimum requirements for commissioning and QA of treatment planning dose calculations. We present our experience in the validation of a commercial treatment planning system based on MPPG 5.a. Methods: In addition to tests traditionally performed to commission a model-based dose calculation algorithm, extensive tests were carried out at short and extended SSDs, various depths, oblique gantry angles and off-axis conditions to verify the robustness and limitations of a dose calculation algorithm. A comparison between measured and calculated dose was performed based on validation tests and evaluation criteria recommendedmore » by MPPG 5.a. An ion chamber was used for the measurement of dose at points of interest, and diodes were used for photon IMRT/VMAT validations. Dose profiles were measured with a three-dimensional scanning system and calculated in the TPS using a virtual water phantom. Results: Calculated and measured absolute dose profiles were compared at each specified SSD and depth for open fields. The disagreement is easily identifiable with the difference curve. Subtle discrepancy has revealed the limitation of the measurement, e.g., a spike at the high dose region and an asymmetrical penumbra observed on the tests with an oblique MLC beam. The excellent results we had (> 98% pass rate on 3%/3mm gamma index) on the end-to-end tests for both IMRT and VMAT are attributed to the quality beam data and the good understanding of the modeling. The limitation of the model and the uncertainty of measurement were considered when comparing the results. Conclusion: The extensive tests recommended by the MPPG encourage us to understand the accuracy and limitations of a dose algorithm as well as the uncertainty of measurement. Our experience has shown how the suggested tests can be performed effectively to validate dose calculation models.« less
Dauer, Lawrence T; Ainsbury, Elizabeth A; Dynlacht, Joseph; Hoel, David; Klein, Barbara E K; Mayer, Don; Prescott, Christina R; Thornton, Raymond H; Vano, Eliseo; Woloschak, Gayle E; Flannery, Cynthia M; Goldstein, Lee E; Hamada, Nobuyuki; Tran, Phung K; Grissom, Michael P; Blakely, Eleanor A
2016-02-01
Previous National Council on Radiation Protection and Measurements (NCRP) publications have addressed the issues of risk and dose limitation in radiation protection and included guidance on specific organs and the lens of the eye. NCRP decided to prepare an updated commentary intended to enhance the previous recommendations provided in earlier reports. The NCRP Scientific Committee 1-23 (SC 1-23) is charged with preparing a commentary that will evaluate recent studies on the radiation dose response for the development of cataracts and also consider the type and severity of the cataracts as well as the dose rate; provide guidance on whether existing dose limits to the lens of the eye should be changed in the United States; and suggest research needs regarding radiation effects on and dose limits to the lens of the eye. A status of the ongoing work of SC 1-23 was presented at the Annual Meeting, "Changing Regulations and Radiation Guidance: What Does the Future Hold?" The following represents a synopsis of a few main points in the current draft commentary. It is likely that several changes will be forthcoming as SC 1-23 responds to subject matter expert review and develops a final document, expected by mid 2016.
20 CFR 220.102 - Non-severe impairment(s), defined.
Code of Federal Regulations, 2013 CFR
2013-04-01
... significantly limit the claimant's physical or mental ability to do basic work activities. (b) Basic work activities. Basic work activities means the ability and aptitudes necessary to do most jobs. Examples of... supervision, co-workers and usual work situations; and (6) Dealing with changes in a routine work setting. ...
20 CFR 220.102 - Non-severe impairment(s), defined.
Code of Federal Regulations, 2014 CFR
2014-04-01
... significantly limit the claimant's physical or mental ability to do basic work activities. (b) Basic work activities. Basic work activities means the ability and aptitudes necessary to do most jobs. Examples of... supervision, co-workers and usual work situations; and (6) Dealing with changes in a routine work setting. ...
20 CFR 220.102 - Non-severe impairment(s), defined.
Code of Federal Regulations, 2011 CFR
2011-04-01
... significantly limit the claimant's physical or mental ability to do basic work activities. (b) Basic work activities. Basic work activities means the ability and aptitudes necessary to do most jobs. Examples of... supervision, co-workers and usual work situations; and (6) Dealing with changes in a routine work setting. ...
20 CFR 220.102 - Non-severe impairment(s), defined.
Code of Federal Regulations, 2012 CFR
2012-04-01
... significantly limit the claimant's physical or mental ability to do basic work activities. (b) Basic work activities. Basic work activities means the ability and aptitudes necessary to do most jobs. Examples of... supervision, co-workers and usual work situations; and (6) Dealing with changes in a routine work setting. ...
48 CFR 1527.404 - Basic rights in data clause.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Basic rights in data clause... GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Data and Copyrights 1527.404 Basic rights in data clause. The Contracting Officer shall insert in the Limited Rights Notice when...
Komatsu, Setsuko; Takasaki, Hironori
2009-07-01
Genes regulated by gibberellin (GA) during leaf sheath elongation in rice seedlings were identified using the transcriptome approach. mRNA from the basal regions of leaf sheaths treated with GA3 was analyzed by high-coverage gene expression profiling. 33,004 peaks were detected, and 30 transcripts showed significant changes in the presence of GA3. Among these, basic helix-loop-helix transcription factor (AK073385) was significantly upregulated. Quantitative PCR analysis confirmed that expression of AK073385 was controlled by GA3 in a time- and dose-dependent manner. Basic helix-loop-helix transcription factor (AK073385) is therefore involved in the regulation of gene expression by GA3.
Belogurov, Alexey; Zakharov, Konstantin; Lomakin, Yakov; Surkov, Kirill; Avtushenko, Sergey; Kruglyakov, Peter; Smirnov, Ivan; Makshakov, Gleb; Lockshin, Curtis; Gregoriadis, Gregory; Genkin, Dmitry; Gabibov, Alexander; Evdoshenko, Evgeniy
2016-10-01
Previously, we showed that CD206-targeted liposomal delivery of co-encapsulated immunodominant myelin basic protein (MBP) sequences MBP 46-62 , MBP 124-139 and MBP 147-170 (Xemys) suppressed experimental autoimmune encephalomyelitis in dark Agouti rats. The objective of this study was to assess the safety of Xemys in the treatment of patients with relapsing-remitting multiple sclerosis (MS) and secondary progressive MS, who failed to achieve a sustained response to first-line disease-modifying therapies. In this phase I, open-label, dose-escalating, proof-of-concept study, 20 patients with relapsing-remitting or secondary progressive MS received weekly subcutaneously injections with ascending doses of Xemys up to a total dose of 2.675 mg. Clinical examinations, including Expanded Disability Status Scale score, magnetic resonance imaging results, and serum cytokine concentrations, were assessed before the first injection and for up to 17 weeks after the final injection. Xemys was safe and well tolerated when administered for 6 weeks to a maximum single dose of 900 μg. Expanded Disability Status Scale scores and numbers of T2-weighted and new gadolinium-enhancing lesions on magnetic resonance imaging were statistically unchanged at study exit compared with baseline; nonetheless, the increase of number of active gadolinium-enhancing lesions on weeks 7 and 10 in comparison with baseline was statistically significant. During treatment, the serum concentrations of the cytokines monocyte chemoattractant protein-1, macrophage inflammatory protein-1β, and interleukin-7 decreased, whereas the level of tumor necrosis factor-α increased. These results provide evidence for the further development of Xemys as an antigen-specific, disease-modifying therapy for patients with MS.
NASA Astrophysics Data System (ADS)
Raffi, Julie A.
Intracavitary accelerated partial breast irradiation (APBI) is a method of treating early stage breast cancer using a high dose rate (HDR) brachytherapy source positioned within the lumpectomy cavity. An expandable applicator stretches the surrounding tissue into a roughly spherical or elliptical shape and the dose is prescribed to 1 cm beyond the edge of the cavity. Currently, dosimetry for these treatments is most often performed using the American Association of Physicists in Medicine Task Group No. 43 (TG-43) formalism. The TG-43 dose-rate equation determines the dose delivered to a homogeneous water medium by scaling the measured source strength with standardized parameters that describe the radial and angular features of the dose distribution. Since TG-43 parameters for each source model are measured or calculated in a homogeneous water medium, the dosimetric effects of the patient's dimensions and composition are not accounted for. Therefore, the accuracy of TG-43 calculations for intracavitary APBI is limited by the presence of inhomogeneities in and around the target volume. Specifically, the breast is smaller than the phantoms used to determine TG-43 parameters and is surrounded by air, ribs, and lung tissue. Also, the composition of the breast tissue itself can affect the dose distribution. This dissertation is focused on investigating the limitations of TG-43 dosimetry for intracavitary APBI for two HDR brachytherapy sources: the VariSource TM VS2000 192Ir source and the AxxentRTM miniature x-ray source. The dose for various conditions was determined using thermoluminescent dosimeters (TLDs) and Monte Carlo (MC) calculations. Accurate measurements and calculations were achieved through the implementation of new measurement and simulation techniques and a novel breast phantom was developed to enable anthropomorphic phantom measurements. Measured and calculated doses for phantom and patient geometries were compared with TG-43 calculated doses to illustrate the limitations of TG-43 dosimetry for intracavitary APBI. TG-43 dose calculations overestimate the dose for regions approaching the lung and breast surface and underestimate the dose for regions in and beyond less-attenuating media such as lung tissue, and for lower energies, breast tissue as well.
Vocal Dose Measures: Quantifying Accumulated Vibration Exposure in Vocal Fold Tissues
Titze, Ingo R.; Švec, Jan G.; Popolo, Peter S.
2011-01-01
To measure the exposure to self-induced tissue vibration in speech, three vocal doses were defined and described: distance dose, which accumulates the distance that tissue particles of the vocal folds travel in an oscillatory trajectory; energy dissipation dose, which accumulates the total amount of heat dissipated over a unit volume of vocal fold tissues; and time dose, which accumulates the total phonation time. These doses were compared to a previously used vocal dose measure, the vocal loading index, which accumulates the number of vibration cycles of the vocal folds. Empirical rules for viscosity and vocal fold deformation were used to calculate all the doses from the fundamental frequency (F0) and sound pressure level (SPL) values of speech. Six participants were asked to read in normal, monotone, and exaggerated speech and the doses associated with these vocalizations were calculated. The results showed that large F0 and SPL variations in speech affected the dose measures, suggesting that accumulation of phonation time alone is insufficient. The vibration exposure of the vocal folds in normal speech was related to the industrial limits for hand-transmitted vibration, in which the safe distance dose was derived to be about 500 m. This limit was found rather low for vocalization; it was related to a comparable time dose of about 17 min of continuous vocalization, or about 35 min of continuous reading with normal breathing and unvoiced segments. The voicing pauses in normal speech and dialogue effectively prolong the safe time dose. The derived safety limits for vocalization will likely require refinement based on a more detailed knowledge of the differences in hand and vocal fold tissue morphology and their response to vibrational stress, and on the effect of recovery of the vocal fold tissue during voicing pauses. PMID:12959470
Vocal dose measures: quantifying accumulated vibration exposure in vocal fold tissues.
Titze, Ingo R; Svec, Jan G; Popolo, Peter S
2003-08-01
To measure the exposure to self-induced tissue vibration in speech, three vocal doses were defined and described: distance dose, which accumulates the distance that tissue particles of the vocal folds travel in an oscillatory trajectory; energy dissipation dose, which accumulates the total amount of heat dissipated over a unit volume of vocal fold tissues; and time dose, which accumulates the total phonation time. These doses were compared to a previously used vocal dose measure, the vocal loading index, which accumulates the number of vibration cycles of the vocal folds. Empirical rules for viscosity and vocal fold deformation were used to calculate all the doses from the fundamental frequency (F0) and sound pressure level (SPL) values of speech. Six participants were asked to read in normal, monotone, and exaggerated speech and the doses associated with these vocalizations were calculated. The results showed that large F0 and SPL variations in speech affected the dose measures, suggesting that accumulation of phonation time alone is insufficient. The vibration exposure of the vocal folds in normal speech was related to the industrial limits for hand-transmitted vibration, in which the safe distance dose was derived to be about 500 m. This limit was found rather low for vocalization; it was related to a comparable time dose of about 17 min of continuous vocalization, or about 35 min of continuous reading with normal breathing and unvoiced segments. The voicing pauses in normal speech and dialogue effectively prolong the safe time dose. The derived safety limits for vocalization will likely require refinement based on a more detailed knowledge of the differences in hand and vocal fold tissue morphology and their response to vibrational stress, and on the effect of recovery of the vocal fold tissue during voicing pauses.
Deal, Samantha; Wambaugh, John; Judson, Richard; Mosher, Shad; Radio, Nick; Houck, Keith; Padilla, Stephanie
2016-09-01
One of the rate-limiting procedures in a developmental zebrafish screen is the morphological assessment of each larva. Most researchers opt for a time-consuming, structured visual assessment by trained human observer(s). The present studies were designed to develop a more objective, accurate and rapid method for screening zebrafish for dysmorphology. Instead of the very detailed human assessment, we have developed the computational malformation index, which combines the use of high-content imaging with a very brief human visual assessment. Each larva was quickly assessed by a human observer (basic visual assessment), killed, fixed and assessed for dysmorphology with the Zebratox V4 BioApplication using the Cellomics® ArrayScan® V(TI) high-content image analysis platform. The basic visual assessment adds in-life parameters, and the high-content analysis assesses each individual larva for various features (total area, width, spine length, head-tail length, length-width ratio, perimeter-area ratio). In developing the computational malformation index, a training set of hundreds of embryos treated with hundreds of chemicals were visually assessed using the basic or detailed method. In the second phase, we assessed both the stability of these high-content measurements and its performance using a test set of zebrafish treated with a dose range of two reference chemicals (trans-retinoic acid or cadmium). We found the measures were stable for at least 1 week and comparison of these automated measures to detailed visual inspection of the larvae showed excellent congruence. Our computational malformation index provides an objective manner for rapid phenotypic brightfield assessment of individual larva in a developmental zebrafish assay. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Polig, E.; Jee, W. S.; Kruglikov, I. L.
1992-01-01
Factors relating the local concentration of a bone-seeking alpha-particle emitter to the mean hit rate have been determined for nuclei of bone lining cells using a Monte Carlo procedure. Cell nuclei were approximated by oblate spheroids with dimensions and location taken from a previous histomorphometric study. The Monte Carlo simulation is applicable for planar and diffuse labels at plane or cylindrical bone surfaces. Additionally, the mean nuclear dose per hit, the dose mean per hit, the mean track segment length and its second moment, the percentage of stoppers, and the frequency distribution of the dose have been determined. Some basic features of the hit statistics for bone lining cells have been outlined, and the consequences of existing standards of radiation protection with regard to the hit frequency to cell nuclei are discussed.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the next, so that in any single year an employee may have a maximum of four weeks' vacation time. At... agreement providing for the deferral), the value of any unused vacation time from the prior year in excess... amount is the lesser of two times the basic annual limitation ($30,000) or the sum of the basic annual...
Code of Federal Regulations, 2011 CFR
2011-04-01
... the next, so that in any single year an employee may have a maximum of four weeks' vacation time. At... agreement providing for the deferral), the value of any unused vacation time from the prior year in excess... amount is the lesser of two times the basic annual limitation ($30,000) or the sum of the basic annual...
Kepka, Lucyna; Bujko, Krzysztof; Zolciak-Siwinska, Agnieszka; Garmol, Dariusz
2008-01-01
To estimate the doses of incidental irradiation in particular lymph node stations (LNS) in different extents of elective nodal irradiation (ENI) in 3D-conformal radiotherapy (3D-CRT) for non-small cell lung cancer (NSCLC). METHODS; Doses of radiotherapy were estimated for particular LNS delineated according to the recommendations of the University of Michigan in 220 patients treated using 3D-CRT with different (extended, limited and omitted) extents of ENI. Minimum doses and volumes of LNS receiving 40 Gy or more (V40) were compared for omitted vs. limited+ extended ENI and limited vs. extended ENI. For omission of the ENI the minimum doses and V40 for particular LNS were significantly lower than for patients treated with ENI. For the limited ENI group, the minimum doses for LNS 5, 6 lower parts of 3A and 3P (not included in the elective area) did not differ significantly from doses given to respective LNS for extended ENI group. When the V40 values for extended and limited ENI were compared, no significant differences were seen for any LNS, except for group 1/2R, 1/2L. Incidental irradiation of untreated LNS seems play a part in case of limited ENI, but not in cases without ENI. For subclinical disease the delineation of uninvolved LNS 5, 6, and lower parts of 3A, 3P may be not necessary, because these stations receive the substantial part of irradiation incidentally, if LNS 4R, 4L, 7, and ipsilateral hilum are included in the elective area while this is not case for stations 1 and 2.
Basic PK/PD principles of drug effects in circular/proliferative systems for disease modelling.
Jacqmin, Philippe; McFadyen, Lynn; Wade, Janet R
2010-04-01
Disease progression modelling can provide information about the time course and outcome of pharmacological intervention on the disease. The basic PK/PD principles of proliferative and circular systems within the context of modelling disease progression and the effect of treatment thereupon are illustrated with the goal to better understand/predict eventual clinical outcome. Circular/proliferative systems can be very complex. To facilitate the understanding of how a dosing regimen can be defined in such systems we have shown the derivation of a system parameter named the Reproduction Minimum Inhibitory Concentration (RMIC) which represents the critical concentration at which the system switches from growth to extinction. The RMIC depends on two parameters (RMIC = (R(0) - 1) x IC(50)): the basic reproductive ratio (R(0)) a fundamental parameter of the circular/proliferative system that represents the number of offspring produced by one replicating species during its lifespan, and the IC(50), the potency of the drug to inhibit the proliferation of the system. The RMIC is constant for a given system and a given drug and represents the lowest concentration that needs to be achieved for eradication of the system. When exposure is higher than the RMIC, success can be expected in the long term. Time varying inhibition of replicating species proliferation is a natural consequence of the time varying inhibitor drug concentrations and when combined with the dynamics of the circular/proliferative system makes it difficult to predict the eventual outcome. Time varying inhibition of proliferative/circular systems can be handled by calculating the equivalent effective constant concentration (ECC), the constant plasma concentration that would give rise to the average inhibition at steady state. When ECC is higher than the RMIC, eradication of the system can be expected. In addition, it is shown that scenarios that have the same steady state ECC whatever the dose, dosage schedule or PK parameters have also the same average R (0) in the presence of the inhibitor (i.e. R (0-INH)) and therefore lead to the same outcome. This allows predicting equivalent active doses and dosing schedules in circular and proliferative systems when the IC(50) and pharmacokinetic characteristics of the drugs are known. The results from the simulations performed demonstrate that, for a given system (defined by its RMIC), treatment success depends mainly on the pharmacokinetic characteristics of the drug and the dosing schedule.
10 CFR 20.1208 - Dose equivalent to an embryo/fetus.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20.1208 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose...
10 CFR 20.1208 - Dose equivalent to an embryo/fetus.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20.1208 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose...
10 CFR 20.1208 - Dose equivalent to an embryo/fetus.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20.1208 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose...
10 CFR 20.1208 - Dose equivalent to an embryo/fetus.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20.1208 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose...
10 CFR 20.1208 - Dose equivalent to an embryo/fetus.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20.1208 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose...
Li, Xiang; Sun, Ming-Zhu; Li, Xu; Zhang, Shu-Hui; Dai, Liang-Ti; Liu, Xing-Yu; Zhao, Xin; Chen, Dong-Yan; Feng, Xi-Zeng
2017-11-01
The extensive usage of xenobiotic endocrine disrupting chemicals (XEDCs), such as Bisphenol A (BPA), has created obvious threat to aquatic ecosystems worldwide. Although a comprehensive understanding of the adverse effect of BPA on behaviors and physiology have been proven, the potential impact of low-dose BPA on altering the basic ability of aquatic organism in adapting to the surrounded complex environment still remains elusive. In this research, we report that treatment of adult male zebrafish with chronic (7 weeks) low-dose (0.22 nM-2.2 nM) BPA, altered the ability in adapting the complex environment by disturbing the natural color preference patterns. In addition, chronic 50 ng/L (0.22 nM) BPA exposure alleviated the anxiety behavior of male zebrafish confronted with the novel environment by enhancing the preference towards light in the light/dark preference test. This phenotype was associated with less expression of serotonin (5-TH) in the hypothalamus and the down-regulation of tyrosine hydroxylase (TH) in brain tissues. As such, our results show that low-dose BPA remnant in surface waters altered zebrafish behavior that are known to have ecological and evolutionary consequences. Here we reported that the impact of chronic low-dose BPA exposure on the basic capability of zebrafish to adapt to the environmental complexity. Specifically, BPA at low concentration, under the environmental safety level and 3000-fold lower than the accepted human daily exposure, interfered with the ability to discriminate color and alleviate anxiety induced by the novel environment, which finally altered the capability of male zebrafish to adapt to the environmental complexity. These findings revealed the ecological effect of low-dose BPA and regular BPA concentration standard are not necessarily safe. The result also provided the consideration of retuning the hazard concentration level of BPA. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zha, Lin-Hua; He, Li-Sha; Lian, Feng-Mei; Zhen, Zhong; Ji, Hang-Yu; Xu, Li-Peng; Tong, Xiao-Lin
2015-01-01
The clinical therapeutics of traditional Chinese medicine (TCM) constitutes a complicated process which involves theory, diagnosis, and formula prescription with specific herbal dosage. Zhang Zhong-Jing's classic work, Treatise on Febrile and Miscellaneous Diseases, has been influencing TCM practice for almost 2000 years. However, during this extended period of time in Chinese history, the Chinese weight measurement system experienced noticeable changes. This change in the weight measurement system inevitably, and perhaps even negatively, affected TCM herbal dosage determination and treatment outcome. Thus, in modern society, a full understanding of the accuracy of herbal dose selection has a critical importance in the TCM daily practice of delivering the best treatment to the patients suffering from different illnesses. In the 973 Project of the Chinese National Basic Research Program, expert consensus on classic TCM formula dose conversion has been reached based on extensive literature review and discussion on the dose-effect relationship of classic TCM formulas. One "liang" in classic TCM formulas is equivalent to 13.8 g. However, based on many TCM basic and clinical studies of variable herbal formula prescriptions and herbal drug preparations, the rule of one liang equals 13.8 g should be adjusted according to different disease conditions. Recommended by the committee on TCM formula dose-effect relationship of the China Association of Chinese Medicine and the World Federation of Chinese Medicine Societies, the following expert consensus has been reached: (i) One liang converts to 6-9 g for the severely and critically ill patients. (ii) One liang converts to 3-6 g for the patients suffering from chronic diseases. (iii) One liang converts to 1-3 g in preventive medicine. The above conversions should be used as a future TCM practice guideline. Using this recommended guideline should enhance the effectiveness of daily TCM practice.
[Experimental study on the impact of photodynamic therapy on the normal vocal cord injury].
Liu, Haiyan; Huang, Yongwang; Wang, Shanshan; Li, Yingxin; Yin, Huijuan; Gao, Xiaowei
2015-12-01
To investigate the reactive characteristics of normal vocal cord tissues to photodynamic therapy (PDT) and the damage effects of different concentration of photosensitizer and different light on normal rabbit vocal cord. Making the preliminary research of PDT in clinical treatment of chronic inflammation of the vocal cords and precancerous lesions. Twenty-five healthy Japanese big ear experimental rabbits were randomly divided into 5 groups: low work rate low dose group A (100 mW, 10%5-ALA), high work rate low dose group B (200 mW, 10%5-ALA), high work rate high dose group C (200 mW, 20%5-ALA), low work rate high dose group D (100 mW, 20%5-ALA) and normal control group E. The issue damage and wound recovery were observed in 1 d, 3 d, 7 d, 14 d, 28 d after intervention. A severe inflammation reaction was observed in group A, B, C, D after intervened with PDT compared to normal group. The reaction of group A was lighter, and the reaction of group C was the most serious. The content of collagenous fiber, hyaluronic acid and fibronectin in vocal fold lamina layer was significantly higher than that in normal group (P<0.05). Different degrees of fiber proliferation were observed in all groups. The content of each component of vocal fold lamina layer tended to be normal slightly higher level in 28 d. Observation by electron microscope showed that there were no significant differences in A, B, C, D, E in 28 d after intervention. Recoverable damage repair process can be detected in rabbit vocal after intervened with PDT, which began in 7 d and basically completed in 28 d. In a certain concentration (10%-20%) and dose range (100-200 mW). The higher of photodynamic dose, the more serious of the damage. And the damage was basically reversible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rees, Brian G.
These are slides from a presentation on the basics of neutrons. A few topics covered are: common origins of terrestrial neutron radiation, neutron sources, neutron energy, interactions, detecting neutrons, gammas from neutron interactions, neutron signatures in gamma-ray spectra, neutrons and NaI, neutron fluence to dose (msV), instruments' response to neutrons.
Spatial frequency performance limitations of radiation dose optimization and beam positioning
NASA Astrophysics Data System (ADS)
Stewart, James M. P.; Stapleton, Shawn; Chaudary, Naz; Lindsay, Patricia E.; Jaffray, David A.
2018-06-01
The flexibility and sophistication of modern radiotherapy treatment planning and delivery methods have advanced techniques to improve the therapeutic ratio. Contemporary dose optimization and calculation algorithms facilitate radiotherapy plans which closely conform the three-dimensional dose distribution to the target, with beam shaping devices and image guided field targeting ensuring the fidelity and accuracy of treatment delivery. Ultimately, dose distribution conformity is limited by the maximum deliverable dose gradient; shallow dose gradients challenge techniques to deliver a tumoricidal radiation dose while minimizing dose to surrounding tissue. In this work, this ‘dose delivery resolution’ observation is rigorously formalized for a general dose delivery model based on the superposition of dose kernel primitives. It is proven that the spatial resolution of a delivered dose is bounded by the spatial frequency content of the underlying dose kernel, which in turn defines a lower bound in the minimization of a dose optimization objective function. In addition, it is shown that this optimization is penalized by a dose deposition strategy which enforces a constant relative phase (or constant spacing) between individual radiation beams. These results are further refined to provide a direct, analytic method to estimate the dose distribution arising from the minimization of such an optimization function. The efficacy of the overall framework is demonstrated on an image guided small animal microirradiator for a set of two-dimensional hypoxia guided dose prescriptions.
Dosimetry for photo-coagulation by the use of autofluorescence
NASA Astrophysics Data System (ADS)
Brodzinski, T.
1989-01-01
A basic problem when using lasers in medicine is that of dosimetry. The definition of the terms dose, effective value etc. will be dealt with in Chapter 2. This chapter is intended to give an insight into the problems of basic dosimetry and its technical realization within the field of photocoagulation, an established method used to treat the retina, or some skin diseases. Until now the coagulation process was assessed to be completed when the irradiated area became blanched. However in terms of dosimetry, it must be possible to predict or at least to monitor the biological effect using well-defined parameters for the laser or in achieving an objective measure for a feedback loop. In the case of coagulation, a prediction in this form is not possible. There are two ways of pro- ceeding further see Fig. 1. One can either determine the physical effect, i.e. temperature, by some kind of sensors, or even better, use some biological effect as a direct measure of the effective dose applied.
Basic principles of molecular effects of irradiation.
Selzer, Edgar; Hebar, Alexandra
2012-02-01
In order to understand the consequences of radiation a thorough understanding of the radiobiological mechanisms of the molecular up to the clinical level is of importance. Radiobiology therefore combines the basic principles of physics as well as biology and medicine and is concerned with the action of radiation from the subcellular level up to the living organism. Topics of interest and relevance are covered in much more broadness as is possible in the short following article in the literature to which the interested reader is referred to. Classical books in this field were written by Steel et al. (1989) as well as by Hall (1994). Topics usually covered by radiobiological reviews are the classification of different types of radiation, cell cycle dependency of radiation effects, types of radiation damage and cell death, dose response curves, measurement of radiation damage, the oxygen effect, relative biological effectiveness, the influence of dose rate, and several other important research areas. This short overview will concentrate on a subset of radiobiological topics of high importance and relative novelty.
Velikyan, Irina; Antoni, Gunnar; Sörensen, Jens; Estrada, Sergio
2013-01-01
Positron Emission Tomography (PET) and in particular gallium-68 (68Ga) applications are growing exponentially worldwide contributing to the expansion of nuclear medicine and personalized management of patients. The significance of 68Ga utility is reflected in the implementation of European Pharmacopoeia monographs. However, there is one crucial point in the monographs that might limit the use of the generators and consequently expansion of 68Ga applications and that is the limit of 0.001% of Germanium-68 (68Ge(IV)) radioactivity content in a radiopharmaceutical. We have investigated the organ distribution of 68Ge(IV) in rat and estimated human dosimetry parameters in order to provide experimental evidence for the determination and justification of the 68Ge(IV) limit. Male and female rats were injected in the tail vein with formulated [68Ge]GeCl4 in the absence or presence of [68Ga]Ga-DOTA-TOC. The tissue radioactivity distribution data was extrapolated for the estimation of human organ equivalent doses and total effective dose using Organ Level Internal Dose Assessment Code software (OLINDA/EXM). 68Ge(IV) was evenly distributed among the rat organs and fast renal excretion prevailed. Human organ equivalent dose and total effective dose estimates indicated that the kidneys were the dose-limiting organs (185±54 μSv/MBq for female and 171±38 μSv/MBq for male) and the total effective dose was 15.5±0.1 and 10.7±1.2 μSv/MBq, respectively for female and male. The results of this dosimetry study conclude that the 68Ge(IV) limit currently recommended by monographs could be increased considerably (>100 times) without exposing the patient to harm given the small absorbed doses to normal organs and fast excretion. PMID:23526484
Eye doses to staff in a nuclear medicine department.
Summers, Elizabeth C; Brown, Janis L E; Bownes, Peter J; Anderson, Shona E
2012-05-01
Occupational radiation doses to the Nuclear Medicine Department staff at Mount Vernon Hospital are routinely measured using optically stimulated luminescence dosemeters for whole-body effective dose and ring thermoluminescence dosemeters (TLDs) for finger dose. In 2002, a project was carried out using LiF:Mg,Cu,P Chinese TLDs to measure the dose to the lens of the eye received by staff during normal working procedures. Separate pairs of TLDs were worn by staff on their forehead between their eyes while dispensing and releasing in the radiopharmacy, injecting, and when administering I-131 capsules to patients. The dose received was calculated using calibration data from identical TLDs irradiated with Tc-99m, I-131, and the Ir-192 source of a Gammamed High Dose Rate (HDR) treatment unit. Data were collected over a 5-month period and the mean dose to the eye was calculated for each procedure. Using a typical yearly workload, the annual dose to the eye for a single member of staff was calculated and found to be 4.5 mSv. The occupational eye dose limit was, at the time, 150 mSv; therefore, staff were well below the level (3/10th of this limit) that would have required them to be classified. However, there have been large increases in radiopharmacy production and I-131 therapies administered at Mount Vernon in subsequent years. It is therefore expected that the eye dose received by staff will have increased to be significantly higher than 4.5 mSv and will in fact be greater than 6 mSv, which is 3/10th of the proposed new dose limit and would require these staff to become classified workers.
Examining Adult Basic Education in Indiana
ERIC Educational Resources Information Center
Hawkins, Alishea
2017-01-01
While it is known that over 500,000 individuals in the State of Indiana have not obtained a High School Diploma or Equivalency (StatsIndiana, 2015), limited empirical information exists on Indiana students pursuing adult basic education along with implications for a state that has changed its adult basic education high stakes high school…
Hydrogen peroxide kinetics in water radiolysis
NASA Astrophysics Data System (ADS)
Iwamatsu, Kazuhiro; Sundin, Sara; LaVerne, Jay A.
2018-04-01
The kinetics of the formation and reaction of hydrogen peroxide in the long time γ- radiolysis of water is examined using a combination of experiment with model calculations. Escape yields of hydrogen peroxide on the microsecond time scale are easily measured with added radical scavengers even with substantial amounts of initial added hydrogen peroxide. The γ-radiolysis of aqueous hydrogen peroxide solutions without added radical scavengers reach a steady state limiting concentration of hydrogen peroxide with increasing dose, and that limit is directly proportional to the initial concentration of added hydrogen peroxide. The dose necessary to reach that limiting hydrogen peroxide concentration is also proportional to the initial concentration, but dose rate has a very small effect. The addition of molecular hydrogen to aqueous solutions of hydrogen peroxide leads to a decrease in the high dose limiting hydrogen peroxide concentration that is linear with the initial hydrogen concentration, but the amount of decrease is not stoichiometric. Proton irradiations of solutions with added hydrogen peroxide and hydrogen are more difficult to predict because of the decreased yields of radicals; however, with a substantial increase in dose rate there is a sufficient decrease in radical yields that hydrogen addition has little effect on hydrogen peroxide decay.
NASA Technical Reports Server (NTRS)
Wallace, R.; Boyer, M. F.
1972-01-01
These direct measurements are in fair agreement with computations made using a program which considers both basic cosmic ray atmospheric physics and the focusing effect of the earth's magnetic field. These measurements also agree with those made at supersonic jet aircraft altitudes in Rb-57 aircraft. It is concluded that experiments and theory show that the doses received at conventional jet aircraft altitudes are slightly higher than those encountered in supersonic flights at much higher altitudes.
Fatigue and pain limit independent mobility and physiotherapy after hip fracture surgery.
Münter, Kristine H; Clemmesen, Christopher G; Foss, Nicolai B; Palm, Henrik; Kristensen, Morten T
2018-07-01
The patient's ability to complete their planned physiotherapy session after hip fracture surgery has been proposed as an independent predictor for achieving basic mobility independency upon hospital discharge. However, knowledge of factors limiting mobility is sparse. We therefore examined patient reported factors limiting ability to complete planned physiotherapy sessions as well as limitations for not achieving independency in basic mobility early after hip fracture surgery. A total of 204 consecutive patients with a hip fracture (mean (SD) age of 80 (9.9) years, 47 patients were admitted from a nursing home) were treated in accordance with a multimodal program. The Cumulated Ambulation Score was used to evaluate the patient's independency in three basic mobility activities: getting in and out of bed, sit-to-stand-to-sit from a chair and indoor walking. Pre-defined limitations; pain, motor blockade, dizziness, fatigue, nausea, acute cognitive dysfunction and "other limitations", for not achieving a full Cumulated Ambulation Score or inability to complete planned physiotherapy sessions were noted by the physiotherapist on each of the three first postoperative days. This period was chosen, because of its importance on how well the patients had regained their pre-fracture functional level. Fatigue and hip fracture-related pain were the most frequent reasons for patients not achieving an independent basic mobility level (> 85%) or not fully completing their planned physiotherapy (> 42%) on all three days. At hospital discharge (median day 10), only 54% of the patients had regained their pre-fracture basic mobility level. Based on the patient's perception, fatigue and pain are the most frequent limitations in not achieving independent basic mobility and not completing physiotherapy after hip fracture surgery. This raises questions whether multimodal peri-operative programs can be further optimized to enhance the early recovery of these frail patients. Implications for rehabilitation Early postoperative mobilization is essential for patients undergoing hip fracture surgery to regain the pre-fracture functional level, in not only the short but also in the long term. The most frequent reasons for not achieving an independent Cumulated Ambulation Score or completing physiotherapy, early after hip fracture surgery, are fatigue, pain, and the habitual cognitive status of patients. Knowledge concerning postoperative fatigue is important for rehabilitation professionals and should contribute as an essential factor when planning physiotherapy.
Effective doses to family members of patients treated with radioiodine-131
NASA Astrophysics Data System (ADS)
Zdraveska Kocovska, M.; Vaskova, O.; Majstorov, V.; Kuzmanovska, S.; Pop Gjorceva, D.; Spasic Jokic, V.
2011-09-01
The purpose of this study was to evaluate the effective dose to family members of thyroid cancer and hyperthyroid patients treated with radioiodine-131, and also to compare the results with dose constraints proposed by the International Commission of Radiological Protection (ICRP) and the Basic Safety Standards (BSS) of the International Atomic Energy Agency (IAEA). For the estimation of the effective doses, sixty family members of sixty patients, treated with radioiodine-131, and thermoluminiscent dosimeters (Model TLD 100) were used. Thyroid cancer patients were hospitalized for three days, while hyperthyroid patients were treated on out-patient basis. The family members wore TLD in front of the torso for seven days. The radiation doses to family members of thyroid cancer patients were well below the recommended dose constraint of 1 mSv. The mean value of effective dose was 0.21 mSv (min 0.02 - max 0.51 mSv). Effective doses, higher than 1 mSv, were detected for 11 family members of hyperthyroid patients. The mean value of effective dose of family members of hyperthyroid patients was 0.87 mSv (min 0.12 - max 6.79). The estimated effective doses to family members of hyperthyroid patients were higher than the effective doses to family members of thyroid carcinoma patients. These findings may be considered when establishing new national guidelines concerning radiation protection and release of patients after a treatment with radioiodine therapy.
McMeekin, D. Scott; Sill, Michael W.; Benbrook, Doris; Darcy, Kathleen M.; Stearns-Kurosawa, Deborah J.; Eaton, Lynne; Yamada, S. Diane
2007-01-01
Objectives A phase II trial was conducted to evaluate the anti-tumor activity and adverse effects of thalidomide in persistent or recurrent endometrial cancer refractory to cytotoxic chemotherapy, and to correlate angiogenesis biomarker expression with clinical outcome. Methods Consenting patients were treated until progression or intolerable toxicity with an oral starting dose of 200 mg thalidomide/day that was to increase by 200 mg every 2 weeks to a target dose of 1000 mg/day. Vascular endothelial growth factor (VEGF), basic fibroblastic growth factor (bFGF), and soluble endothelial protein C receptor (sEPCR) were analyzed by ELISA in pre and post-treatment specimens. Results Twenty-four of 27 patients enrolled in the study were eligible, of whom 2 reached the target dose, 8 progressed before achieving the target dose and 14 refused or had toxicity that prohibited escalation. Two patients (8.3%) remained progression-free ≥ 6 months. There were 3 (12.5%) with partial responses, 2 (8.3%) with stable disease, 15 (62.5%) with increasing disease, and 4 (16.7%) who were inevaluable for response. Median progression-free survival and overall survival were 1.7 months and 6.3 months, respectively. No grade 4 toxicities were observed. Common grade 3 toxicities included hematologic (n=3), cardiovascular (n=3), constitutional (n=3), and neurologic (n=4). Thalidomide did not decrease VEGF or bFGF levels but reduced sEPCR levels in serum. Elevated plasma vascular endothelial growth factor levels were associated with increased risk of progression and death. Conclusions Thalidomide demonstrated limited ability to delay progression (as measured by PFS at 6 months), produce objective responses or reduce angiogenic marker levels in chemotherapy refractory endometrial cancer. VEGF level appears to be prognostically significant in such patients, independent of thalidomide treatment. PMID:17306350
SU-E-T-278: Dose Conformity Index for the Target in a Multitarget Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harikrishnaperumal, Sudahar
2015-06-15
Purpose: The existing conformity index formulations are failing when multiple targets present outside the target of interest with same or different dose prescriptions. In the present study a novel methodology is introduced to solve this issue. Methods: The conformity index used by Nakamura et al (Int J Radiat Oncol Biol Phys 2001; 51(5):1313–1319) is taken as the base for this methodology. In this proposal, the prescription isodose volume (PIV) which normally includes the normal tissue and other target regions is restricted as PIV in annular regions of different thickness around the target of interest. The graphical line plotted between themore » thickness of annular region and the corresponding conformity index, will increase in the beginning and will reach a flat region, then it will increase again. The second increase in the conformity index depends basically on the distance between the targets, dose prescriptions, and size of the targets. The conformity index in the flat region should be the conformity index of the target of interest. This methodology was validated on dual target environment on a skull phantom in Multiplan planning system (Accuray Inc. Sunnyvale, USA) Results: When the surrounding target’s (sphere) size is changed from 1.5cm to 6cm diameter, the conformity index of the target of interest (3cm diameter) changed from 1.09 to 1.25. When the distance between the targets changed from 7.5cm to 2.5cm, the conformity index changed from 1.10 to 1.17. Similarly, when the prescribed dose changed from 25Gy to 50Gy the conformity index changed from 1.09 to 1.42. These values were above 2.0 when Nakamura et al formula was used. Conclusion: The proposed conformity index methodology eliminates the influence of surrounding targets to a greater extend. However, the limitations of this method should be studied further. Application of this method in clinical situations is the future scope.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bentefour, El H., E-mail: hassan.bentefour@iba-group.com; Prieels, Damien; Tang, Shikui
Purpose: In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry. Methods: An anthropomorphic pelvic phantom is used to validate the clinical potential of the time-resolved dose method for range verification inmore » the case of prostrate treatment using range modulated anterior proton beams. The method uses a 3 × 4 matrix of 1 mm diodes mounted in water balloon which are read by an ADC system at 100 kHz. The method is first validated against beam range measurements by dose extinction measurements. The validation is first completed in water phantom and then in pelvic phantom for both open field and treatment field configurations. Later, the beam range results are compared with the water equivalent path length (WEPL) values computed from the treatment planning system XIO. Results: Beam range measurements from both time-resolved dose method and the dose extinction method agree with submillimeter precision in water phantom. For the pelvic phantom, when discarding two of the diodes that show sign of significant range mixing, the two methods agree with ±1 mm. Only a dose of 7 mGy is sufficient to achieve this result. The comparison to the computed WEPL by the treatment planning system (XIO) shows that XIO underestimates the protons beam range. Quantifying the exact XIO range underestimation depends on the strategy used to evaluate the WEPL results. To our best evaluation, XIO underestimates the treatment beam range between a minimum of 1.7% and maximum of 4.1%. Conclusions: Time-resolved dose measurement method satisfies the two basic requirements, WEPL accuracy and minimum dose, necessary for clinical use, thus, its potential for in-vivo protons range verification. Further development is needed, namely, devising a workflow that takes into account the limits imposed by proton range mixing and the susceptibility of the comparison of measured and expected WEPLs to errors on the detector positions. The methods may also be used for in-vivo dosimetry and could benefit various proton therapy treatments.« less
Radiation Hormesis: Historical Perspective and Implications for Low-Dose Cancer Risk Assessment
Vaiserman, Alexander M.
2010-01-01
Current guidelines for limiting exposure of humans to ionizing radiation are based on the linear-no-threshold (LNT) hypothesis for radiation carcinogenesis under which cancer risk increases linearly as the radiation dose increases. With the LNT model even a very small dose could cause cancer and the model is used in establishing guidelines for limiting radiation exposure of humans. A slope change at low doses and dose rates is implemented using an empirical dose and dose rate effectiveness factor (DDREF). This imposes usually unacknowledged nonlinearity but not a threshold in the dose-response curve for cancer induction. In contrast, with the hormetic model, low doses of radiation reduce the cancer incidence while it is elevated after high doses. Based on a review of epidemiological and other data for exposure to low radiation doses and dose rates, it was found that the LNT model fails badly. Cancer risk after ordinarily encountered radiation exposure (medical X-rays, natural background radiation, etc.) is much lower than projections based on the LNT model and is often less than the risk for spontaneous cancer (a hormetic response). Understanding the mechanistic basis for hormetic responses will provide new insights about both risks and benefits from low-dose radiation exposure. PMID:20585444
Introduction to benchmark dose methods and U.S. EPA's benchmark dose software (BMDS) version 2.1.1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, J. Allen, E-mail: davis.allen@epa.gov; Gift, Jeffrey S.; Zhao, Q. Jay
2011-07-15
Traditionally, the No-Observed-Adverse-Effect-Level (NOAEL) approach has been used to determine the point of departure (POD) from animal toxicology data for use in human health risk assessments. However, this approach is subject to substantial limitations that have been well defined, such as strict dependence on the dose selection, dose spacing, and sample size of the study from which the critical effect has been identified. Also, the NOAEL approach fails to take into consideration the shape of the dose-response curve and other related information. The benchmark dose (BMD) method, originally proposed as an alternative to the NOAEL methodology in the 1980s, addressesmore » many of the limitations of the NOAEL method. It is less dependent on dose selection and spacing, and it takes into account the shape of the dose-response curve. In addition, the estimation of a BMD 95% lower bound confidence limit (BMDL) results in a POD that appropriately accounts for study quality (i.e., sample size). With the recent advent of user-friendly BMD software programs, including the U.S. Environmental Protection Agency's (U.S. EPA) Benchmark Dose Software (BMDS), BMD has become the method of choice for many health organizations world-wide. This paper discusses the BMD methods and corresponding software (i.e., BMDS version 2.1.1) that have been developed by the U.S. EPA, and includes a comparison with recently released European Food Safety Authority (EFSA) BMD guidance.« less
NASA Astrophysics Data System (ADS)
Ueno, Yuichiro; Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi; Fujishima, Yasutake; Yoshida, Akira; Umegaki, Kikuo
2018-06-01
We developed a pinhole type gamma camera, using a compact detector module of a pixelated CdTe semiconductor, which has suitable sensitivity and quantitative accuracy for low dose rate fields. In order to improve the sensitivity of the pinhole type semiconductor gamma camera, we adopted three methods: a signal processing method to set the discriminating level lower, a high sensitivity pinhole collimator and a smoothing image filter that improves the efficiency of the source identification. We tested basic performances of the developed gamma camera and carefully examined effects of the three methods. From the sensitivity test, we found that the effective sensitivity was about 21 times higher than that of the gamma camera for high dose rate fields which we had previously developed. We confirmed that the gamma camera had sufficient sensitivity and high quantitative accuracy; for example, a weak hot spot (0.9 μSv/h) around a tree root could be detected within 45 min in a low dose rate field test, and errors of measured dose rates with point sources were less than 7% in a dose rate accuracy test.
Effect of upright tilt on ventricular/vascular coupling in chronically instrumented primates
NASA Technical Reports Server (NTRS)
Tran, C. C.; Latham, R. D.; Self, D. A.; Fanton, J. W.; White, C. D.; Owens, R. W.
1993-01-01
Studies of the hydraulic loading conditions on the heart in humans, especially pulsatile load, have primarily been limited to the supine state. Therefore, we have chosen a nonhuman primate model, the baboon, to assess left ventricular/vascular coupling in both supine and upright positions. Primate subjects were studied by catheterization under sedation and then after surgical implantation of transducers. This allowed the evaluation of postural stress in the chronically instrumented conscious baboon and then after light dissociative doses of ketamine. Basic hemodynamic variables were evaluated for baboons in supine and upright positions. Fourier analysis was applied to aortic pressure and flow to obtain input and characteristic impedance and the ratio of pulsatile (Wp) to total (Wt) left ventricular power (Wp/Wt). The aortic reflected, or backward, pressure was also calculated. Peripheral resistance increased (P = 0.01) and reflected pressure decreased (17.74 +/- 1.50 vs. 15.21 +/- 2 mmHg; P < 0.01) in upright subjects. Characteristic impedance and Wp/Wt were unchanged. Postoperatively, peripheral resistance increased (2,651 +/- 311 vs. 3,667 +/- 276; P < 0.05) and mean power and Wt decreased (P < 0.01) without changes in reflected pressure. All variables were unchanged after light dissociative doses of ketamine. Thus there is no significant change in efficiency of left ventricular/vascular coupling formulated in terms of Wp/Wt or input impedance with postural stress.
Mihok, S; Thompson, P
2012-01-01
Frameworks and methods for the radiological protection of non-human biota have been evolving rapidly at the International Commission on Radiological Protection and through various European initiatives. The International Atomic Energy Agency has incorporated a requirement for environmental protection in the latest revision of its Basic Safety Standards. In Canada, the Canadian Nuclear Safety Commission has been legally obligated to prevent unreasonable risk to the environment since 2000. Licensees have therefore been meeting generic legal requirements to demonstrate adequate control of releases of radioactive substances for the protection of both people and biota for many years. In the USA, in addition to the generic requirements of the Environmental Protection Agency and the Nuclear Regulatory Commission, Department of Energy facilities have also had to comply with specific dose limits after a standard assessment methodology was finalised in 2002. Canadian regulators developed a similar framework for biota dose assessment through a regulatory assessment under the Canadian Environmental Protection Act in the late 1990s. Since then, this framework has been applied extensively to satisfy legal requirements under the Canadian Environmental Assessment Act and the Nuclear Safety and Control Act. After approximately a decade of experience in applying these methods, it is clear that simple methods are fit for purpose, and can be used for making regulatory decisions for existing and planned nuclear facilities. Copyright © 2012. Published by Elsevier Ltd.
A Low LET Radiation Spectrometer for Measuring Particle Doses in Space and Aircraft
NASA Technical Reports Server (NTRS)
Stassinopoulos, E. G.; Stauffer, C. A.; Brucker, G. J.; Dachev, T. P.; Day, John H. (Technical Monitor)
2002-01-01
This paper presents experimental data that demonstrates the feasibility of fabricating a miniature nuclear particle dosimeter for monitoring doses in aircraft and satellites. The basic instrument is a Low Linear-Energy-Transfer (LET) Radiation Spectrometer (LoLRS) that is designed to measure the energy deposited by particles with low LET values. The heart of the instrument is a Silicon-Lithium Drifted Diode (SLDD). Test results show that the LoLRS can be used to monitor the radiation threat to personnel in flights of space- and aircraft and also to generate a comprehensive data base from aviation and satellite measurements that can contribute to the formulation of more accurate environmental radiation models for dose predictions with reduced uncertainty factors.
Clinical Ion Beam Applications: Basic Properties, Application, Quality Control, Planning
NASA Astrophysics Data System (ADS)
Kraft, Gerhard
2009-03-01
Heavy-ion therapy using beam scanning and biological dose optimization is a novel technique of high-precision external radiotherapy. It yields a better perspective for tumor cure of radio-resistant tumors. However, heavy-ion therapy is not a general solution for all types of tumors. As compared to conventional radiotherapy, heavy-ion radiotherapy has the advantages of higher tumor dose, improved sparing of normal tissue in the entrance channel, a more precise concentration of the dose in the target volume with steeper gradients to the normal tissue, and a higher radiobiological effectiveness for tumors which are radio-resistant in conventional therapy. These properties make it possible to treat radio-resistant tumors with great success, including those in close vicinity to critical organs.
Thompson, Reid F; Mayekar, Sonal U; Zhai, Huifang; Both, Stefan; Apisarnthanarax, Smith; Metz, James M; Plastaras, John P; Ben-Josef, Edgar
2014-08-01
Uncontrolled local growth is the cause of death in ∼ 30% of patients with unresectable pancreatic cancers. The addition of standard-dose radiotherapy to gemcitabine has been shown to confer a modest survival benefit in this population. Radiation dose escalation with three-dimensional planning is not feasible, but high-dose intensity-modulated radiation therapy (IMRT) has been shown to improve local control. Still, dose-escalation remains limited by gastrointestinal toxicity. In this study, the authors investigate the potential use of double scattering (DS) and pencil beam scanning (PBS) proton therapy in limiting dose to critical organs at risk. The authors compared DS, PBS, and IMRT plans in 13 patients with unresectable cancer of the pancreatic head, paying particular attention to duodenum, small intestine, stomach, liver, kidney, and cord constraints in addition to target volume coverage. All plans were calculated to 5500 cGy in 25 fractions with equivalent constraints and normalized to prescription dose. All statistics were by two-tailed paired t-test. Both DS and PBS decreased stomach, duodenum, and small bowel dose in low-dose regions compared to IMRT (p < 0.01). However, protons yielded increased doses in the mid to high dose regions (e.g., 23.6-53.8 and 34.9-52.4 Gy for duodenum using DS and PBS, respectively; p < 0.05). Protons also increased generalized equivalent uniform dose to duodenum and stomach, however these differences were small (<5% and 10%, respectively; p < 0.01). Doses to other organs-at-risk were within institutional constraints and placed no obvious limitations on treatment planning. Proton therapy does not appear to reduce OAR volumes receiving high dose. Protons are able to reduce the treated volume receiving low-intermediate doses, however the clinical significance of this remains to be determined in future investigations.
Jacqmin, Dustin J; Bredfeldt, Jeremy S; Frigo, Sean P; Smilowitz, Jennifer B
2017-01-01
The AAPM Medical Physics Practice Guideline (MPPG) 5.a provides concise guidance on the commissioning and QA of beam modeling and dose calculation in radiotherapy treatment planning systems. This work discusses the implementation of the validation testing recommended in MPPG 5.a at two institutions. The two institutions worked collaboratively to create a common set of treatment fields and analysis tools to deliver and analyze the validation tests. This included the development of a novel, open-source software tool to compare scanning water tank measurements to 3D DICOM-RT Dose distributions. Dose calculation algorithms in both Pinnacle and Eclipse were tested with MPPG 5.a to validate the modeling of Varian TrueBeam linear accelerators. The validation process resulted in more than 200 water tank scans and more than 50 point measurements per institution, each of which was compared to a dose calculation from the institution's treatment planning system (TPS). Overall, the validation testing recommended in MPPG 5.a took approximately 79 person-hours for a machine with four photon and five electron energies for a single TPS. Of the 79 person-hours, 26 person-hours required time on the machine, and the remainder involved preparation and analysis. The basic photon, electron, and heterogeneity correction tests were evaluated with the tolerances in MPPG 5.a, and the tolerances were met for all tests. The MPPG 5.a evaluation criteria were used to assess the small field and IMRT/VMAT validation tests. Both institutions found the use of MPPG 5.a to be a valuable resource during the commissioning process. The validation testing in MPPG 5.a showed the strengths and limitations of the TPS models. In addition, the data collected during the validation testing is useful for routine QA of the TPS, validation of software upgrades, and commissioning of new algorithms. © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
[Optimization of enuresis therapy in children using transcranial magnetotherapy].
Otpushchennikova, T V; Kazanskaia, I V; Volkov, S V; Raĭgorodskaia, Iu M
2010-01-01
A total of 58 children (age from 6 to 14 years) suffering from nocturnal enuresis (NE) were divided into two groups. The study group received basic therapy (driptan dose was reduced to 2.5 mg twice a day) in combination with transcranial bitemporal magnetotherapy (TcMT). The control group received placebo TcMT and basic therapy. It is shown that addition of TcMT to reduced basic therapy lowered the score of imperative voiding symptoms 1.3-fold, number of enuresis patients 1.7-fold, volume of the bladder 6.8 months after the treatment 1.9-fold, corrected vegetative status and activity of the subcortical nervous center in 24% children according to cardiointervalography versus the controls. Thus, TcMT improves clinical effect in NE patients in 2-fold reduction of pharmacological burden.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-11
... NUCLEAR REGULATORY COMMISSION [NRC-2009-0279] Impact of Reduced Dose Limits on NRC Licensed Activities; Solicitation of Public Comment AGENCY: Nuclear Regulatory Commission. ACTION: Solicitation of public comment. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC or Commission) is seeking public...
10 CFR 20.2205 - Reports to individuals of exceeding dose limits.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Reports to individuals of exceeding dose limits. 20.2205 Section 20.2205 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Reports..., or an identified member of the public, to radiation or radioactive material, the licensee shall also...
10 CFR 20.2205 - Reports to individuals of exceeding dose limits.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Reports to individuals of exceeding dose limits. 20.2205 Section 20.2205 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Reports..., or an identified member of the public, to radiation or radioactive material, the licensee shall also...
10 CFR 20.2205 - Reports to individuals of exceeding dose limits.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Reports to individuals of exceeding dose limits. 20.2205 Section 20.2205 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Reports..., or an identified member of the public, to radiation or radioactive material, the licensee shall also...
10 CFR 20.2205 - Reports to individuals of exceeding dose limits.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Reports to individuals of exceeding dose limits. 20.2205 Section 20.2205 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Reports..., or an identified member of the public, to radiation or radioactive material, the licensee shall also...
Formalin-fixed paraffin-embedded (FFPE) samples provide a vast untapped resource for chemical safety and translational science. To date, genomic profiling of FFPE samples has been limited by poor RNA quality and inconsistent results with limited utility in dose-response assessmen...
2004-01-01
Abstract A computer program (CalcAnesth) was developed with Visual Basic for the purpose of calculating the doses and prices of injectable medications on the basis of body weight or body surface area. The drug names, concentrations, and prices are loaded from a drug database. This database is a simple text file, that the user can easily create or modify. The animal names and body weights can be loaded from a similar database. After typing the dose and the units into the user interface, the results will be automatically displayed. The program is able to open and save anesthetic protocols, and export or print the results. This CalcAnesth program can be useful in clinical veterinary anesthesiology and research. The rationale for dosing on the basis of body surface area is also discussed in this article. PMID:14979437
Pilocarpine disposition and salivary flow responses following intravenous administration to dogs.
Weaver, M L; Tanzer, J M; Kramer, P A
1992-08-01
Oral doses of pilocarpine increase salivary flow rates in patients afflicted with xerostomia (dry mouth). This study examined the pharmacokinetics of and a pharmacodynamic response (salivation) to intravenous pilocarpine nitrate administration in dogs. Disposition was linear over a dose range of 225-600 micrograms/kg; plasma concentrations were 10-120 micrograms/L. Elimination was rapid and generally biphasic, with a terminal elimination half-life of approximately 1.3 hr. The systemic clearance of pilocarpine was high (2.22 +/- 0.49 L/kg/hr) and its steady-state volume of distribution (2.30 +/- 0.64 L/kg) was comparable to that of many other basic drugs. All doses of pilocarpine induced measurable submaxillary and parotid salivary flow rates which could be maintained constant over time. Cumulative submaxillary saliva flow was linearly related to total pilocarpine dose. Plasma pilocarpine concentration was linearly related to both steady-state and postinfusion submaxillary salivary flow rates.
Adult Education Association of the U.S.A.; Adult Basic Education Study 1965-66.
ERIC Educational Resources Information Center
Firoza, Ahmed, Ed.
The adult basic education (ABE) programs currently conducted by non-governmental organizations in the United States, are reviewed in this document. Attention is focused on the significance of voluntary efforts in adult basic education programs; and strengths and weaknesses, gaps between needs and resources, and limiting factors are identified.…
Vassoler, Fair M; Oliver, David J; Wyse, Cristina; Blau, Ashley; Shtutman, Michael; Turner, Jill R; Byrnes, Elizabeth M
2017-02-01
The United States is in the midst of an opiate epidemic, with abuse of prescription and illegal opioids increasing steadily over the past decade. While it is clear that there is a genetic component to opioid addiction, there is a significant portion of heritability that cannot be explained by genetics alone. The current study was designed to test the hypothesis that maternal exposure to opioids prior to pregnancy alters abuse liability in subsequent generations. Female adolescent Sprague Dawley rats were administered morphine at increasing doses (5-25 mg/kg, s.c.) or saline for 10 days (P30-39). During adulthood, animals were bred with drug-naïve colony males. Male and female adult offspring (F1 animals) were tested for morphine self-administration acquisition, progressive ratio, extinction, and reinstatement at three doses of morphine (0.25, 0.75, 1.25 mg/kg/infusion). Grandoffspring (F2 animals, from the maternal line) were also examined. Additionally, gene expression changes within the nucleus accumbens were examined with RNA deep sequencing (PacBio) and qPCR. There were dose- and sex-dependent effects on all phases of the self-administration paradigm that indicate decreased morphine reinforcement and attenuated relapse-like behavior. Additionally, genes related to synaptic plasticity, as well as myelin basic protein (MBP), were dysregulated. Some, but not all, effects persisted into the subsequent (F2) generation. The results demonstrate that even limited opioid exposure during adolescence can have lasting effects across multiple generations, which has implications for mechanisms of the transmission of drug abuse liability in humans. Copyright © 2016 Elsevier Ltd. All rights reserved.
Dose response evaluation of a low-density normoxic polymer gel dosimeter using MRI
NASA Astrophysics Data System (ADS)
Haraldsson, P.; Karlsson, A.; Wieslander, E.; Gustavsson, H.; Bäck, S. Å. J.
2006-02-01
A low-density (~0.6 g cm-3) normoxic polymer gel, containing the antioxidant tetrakis (hydroxymethyl) phosponium (THP), has been investigated with respect to basic absorbed dose response characteristics. The low density was obtained by mixing the gel with expanded polystyrene spheres. The depth dose data for 6 and 18 MV photons were compared with Monte Carlo calculations. A large volume phantom was irradiated in order to study the 3D dose distribution from a 6 MV field. Evaluation of the gel was carried out using magnetic resonance imaging. An approximately linear response was obtained for 1/T2 versus dose in the dose range of 2 to 8 Gy. A small decrease in the dose response was observed for increasing concentrations of THP. A good agreement between measured and Monte Carlo calculated data was obained, both for test tubes and the larger 3D phantom. It was shown that a normoxic polymer gel with a reduced density could be obtained by adding expanded polystyrene spheres. In order to get reliable results, it is very important to have a uniform distribution of the gel and expanded polystyrene spheres in the phantom volume.
MPC and ALI: their basis and their comparison
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, W.E. Jr.; Watson, E.C.
Radiation protection regulations in the United States have evolved from the recommendations of the International Commission on Radiological Protection (ICRP) and the National Council on Radiation Protection and Measurements (NCRP). In 1959, the ICRP issued Publication 2 which contained specific recommendations on dose rate limits, permissible body burdens, metabolic data for radionuclides, and maximum permissible concentrations (MPC) in air or water. Over the next 20 years, new information became available concerning the effects of radiation, the uptake and retention of radionuclides, and the radioactive decay schemes of parent radionuclides. To include this newer information, the ICRP issued Publication 30 inmore » 1978 to supersede Publication 2. One of the secondary limits defined in Publication 30 is the annual limit of intake (ALI). Radionuclide specific ALI values are intended to replace MPC values in determining whether or not ambient air and water concentrations are sufficiently low to maintain the dose to workers within accepted dose rate limits. In this paper, we discuss the derivation of MPC and ALI values, compare inhalation committed dose equivalent factors derived from ICRP Publications 2 and 30, and discuss the practical implications of using either MPC or ALI in determining compliance with occupational exposure limits. 6 references.« less
10 CFR 20.1203 - Determination of external dose from airborne radioactive material.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Determination of external dose from airborne radioactive material. 20.1203 Section 20.1203 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1203 Determination of external dose from airborne radioactive...
10 CFR 20.1301 - Dose limits for individual members of the public.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Section 20.1301 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiation..., exclusive of the dose contributions from background radiation, from any medical administration the....75, to receive a radiation dose greater than 0.1 rem (1 mSv) if— (1) The radiation dose received does...
10 CFR 20.1301 - Dose limits for individual members of the public.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Section 20.1301 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiation..., exclusive of the dose contributions from background radiation, from any medical administration the....75, to receive a radiation dose greater than 0.1 rem (1 mSv) if— (1) The radiation dose received does...
10 CFR 20.1203 - Determination of external dose from airborne radioactive material.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Determination of external dose from airborne radioactive material. 20.1203 Section 20.1203 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1203 Determination of external dose from airborne radioactive...
10 CFR 20.1301 - Dose limits for individual members of the public.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Section 20.1301 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiation..., exclusive of the dose contributions from background radiation, from any medical administration the....75, to receive a radiation dose greater than 0.1 rem (1 mSv) if— (1) The radiation dose received does...
10 CFR 20.1203 - Determination of external dose from airborne radioactive material.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Determination of external dose from airborne radioactive material. 20.1203 Section 20.1203 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1203 Determination of external dose from airborne radioactive...
10 CFR 20.1301 - Dose limits for individual members of the public.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Section 20.1301 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiation..., exclusive of the dose contributions from background radiation, from any medical administration the....75, to receive a radiation dose greater than 0.1 rem (1 mSv) if— (1) The radiation dose received does...
10 CFR 20.1301 - Dose limits for individual members of the public.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Section 20.1301 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiation..., exclusive of the dose contributions from background radiation, from any medical administration the....75, to receive a radiation dose greater than 0.1 rem (1 mSv) if— (1) The radiation dose received does...
10 CFR 20.1203 - Determination of external dose from airborne radioactive material.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Determination of external dose from airborne radioactive material. 20.1203 Section 20.1203 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1203 Determination of external dose from airborne radioactive...
10 CFR 20.1203 - Determination of external dose from airborne radioactive material.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Determination of external dose from airborne radioactive material. 20.1203 Section 20.1203 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1203 Determination of external dose from airborne radioactive...
NASA Astrophysics Data System (ADS)
Derradji, Mehdi; Zegaoui, Abdeldjalil; Xu, Yi-Le; Wang, An-ran; Dayo, Abdul Qadeer; Wang, Jun; Liu, Wen-bin; Liu, Yu-Guang; Khiari, Karim
2018-04-01
The phthalonitrile resins have claimed the leading place in the field of high performance polymers thanks to their combination of outstanding properties. The present work explores for the first time the gamma rays radiation resistance and shielding efficiency of the phthalonitrile resins and its related tungsten-reinforced nanocomposites. The primary goal of this research is to define the basic behavior of the phthalonitrile resins under highly ionizing gamma rays. The obtained results confirmed that the neat phthalonitrile resins can resist absorbed doses as high as 200 kGy. Meanwhile, the remarkable shielding efficiency of the phthalonitrile polymers was confirmed to be easily improved by preparing lead-free nanocomposites. In fact, the gamma rays screening ratio reached the exceptional value of 42% for the nanocomposites of 50 wt% of nano-tungsten loading. Thus, this study confirms that the remarkable performances of the phthalonitrile resins are not limited to the thermal and mechanical properties and can be extended to the gamma rays radiation and shielding resistances.
Assessing safety of herbal products for menopausal complaints: an international perspective.
Dog, Tieraona Low; Marles, Robin; Mahady, Gail; Gardiner, Paula; Ko, Richard; Barnes, Jo; Chavez, Mary L; Griffiths, James; Giancaspro, Gabriel; Sarma, Nandakumara D
2010-08-01
Future research of herbal products for menopausal women should include long-term safety assessments because women may use these products for prolonged periods of time. Growing numbers of women take prescription medications and concurrently use herbal products for alleviation of menopausal symptoms. Because of possible herb-drug interactions, both drug and supplement manufacturers should provide basic pharmacokinetic data to reduce the risk of adverse interactions. In addition, herbal products produced to high quality standards are essential for ensuring consumer safety. Regulatory frameworks must be in place to ensure that herbal ingredients' identities have been verified, that they have been properly quantified per unit dose, that the product is within tolerance limits for contaminants, that the product's safety and effectiveness under the recommended conditions of use have been assessed before sale to the public, and that a system is in place to detect and deal with adverse reactions when they arise. This article explores these and related concerns. Copyright 2010. Published by Elsevier Ireland Ltd.
Low, D A; Sohn, J W; Klein, E E; Markman, J; Mutic, S; Dempsey, J F
2001-05-01
The characteristics of a commercial multileaf collimator (MLC) to deliver static and dynamic multileaf collimation (SMLC and DMLC, respectively) were investigated to determine their influence on intensity modulated radiation therapy (IMRT) treatment planning and quality assurance. The influence of MLC leaf positioning accuracy on sequentially abutted SMLC fields was measured by creating abutting fields with selected gaps and overlaps. These data were also used to measure static leaf positioning precision. The characteristics of high leaf-velocity DMLC delivery were measured with constant velocity leaf sequences starting with an open field and closing a single leaf bank. A range of 1-72 monitor units (MU) was used providing a range of leaf velocities. The field abutment measurements yielded dose errors (as a percentage of the open field max dose) of 16.7+/-0.7% mm(-1) and 12.8+/-0.7% mm(-1) for 6 MV and 18 MV photon beams, respectively. The MLC leaf positioning precision was 0.080+/-0.018 mm (single standard deviation) highlighting the excellent delivery hardware tolerances for the tested beam delivery geometry. The high leaf-velocity DMLC measurements showed delivery artifacts when the leaf sequence and selected monitor units caused the linear accelerator to move the leaves at their maximum velocity while modulating the accelerator dose rate to deliver the desired leaf and MU sequence (termed leaf-velocity limited delivery). According to the vendor, a unique feature to their linear accelerator and MLC is that the dose rate is reduced to provide the correct cm MU(-1) leaf velocity when the delivery is leaf-velocity limited. However, it was found that the system delivered roughly 1 MU per pulse when the delivery was leaf-velocity limited causing dose profiles to exhibit discrete steps rather than a smooth dose gradient. The root mean square difference between the steps and desired linear gradient was less than 3% when more than 4 MU were used. The average dose per MU was greater and less than desired for closing and opening leaf patterns, respectively, when the delivery was leaf-velocity limited. The results indicated that the dose delivery artifacts should be minor for most clinical cases, but limit the assumption of dose linearity when significantly reducing the delivered dose for dosimeter characterization studies or QA measurements.
Brock, Penelope R.; Knight, Kristin R.; Freyer, David R.; Campbell, Kathleen C.M.; Steyger, Peter S.; Blakley, Brian W.; Rassekh, Shahrad R.; Chang, Kay W.; Fligor, Brian J.; Rajput, Kaukab; Sullivan, Michael; Neuwelt, Edward A.
2012-01-01
Purpose The platinum chemotherapy agents cisplatin and carboplatin are widely used in the treatment of adult and pediatric cancers. Cisplatin causes hearing loss in at least 60% of pediatric patients. Reducing cisplatin and high-dose carboplatin ototoxicity without reducing efficacy is important. Patients and Methods This review summarizes recommendations made at the 42nd Congress of the International Society of Pediatric Oncology (SIOP) in Boston, October 21-24, 2010, reflecting input from international basic scientists, pediatric oncologists, otolaryngologists, oncology nurses, audiologists, and neurosurgeons to develop and advance research and clinical trials for otoprotection. Results Platinum initially impairs hearing in the high frequencies and progresses to lower frequencies with increasing cumulative dose. Genes involved in drug transport, metabolism, and DNA repair regulate platinum toxicities. Otoprotection can be achieved by acting on several these pathways and generally involves antioxidant thiol agents. Otoprotection is a strategy being explored to decrease hearing loss while maintaining dose intensity or allowing dose escalation, but it has the potential to interfere with tumoricidal effects. Route of administration and optimal timing relative to platinum therapy are critical issues. In addition, international standards for grading and comparing ototoxicity are essential to the success of prospective pediatric trials aimed at reducing platinum-induced hearing loss. Conclusion Collaborative prospective basic and clinical trial research is needed to reduce the incidence of irreversible platinum-induced hearing loss, and optimize cancer control. Wide use of the new internationally agreed-on SIOP Boston ototoxicity scale in current and future otoprotection trials should help facilitate this goal. PMID:22547603
Bardo, Dianna M E; Brown, Paul
2008-08-01
Cardiac MDCT is here to stay. And, it is more than just imaging coronary arteries. Understanding the differences in and the benefits of one CT scanner from another will help you to optimize the capabilities of the scanner, but requires a basic understanding of the MDCT imaging physics.This review provides key information needed to understand the differences in the types of MDCT scanners, from 64 - 320 detectors, flat panels, single and dual source configurations, step and shoot prospective and retrospective gating, and how each factor influences radiation dose, spatial and temporal resolution, and image noise.
Hayes, A Wallace; Dixon, Darlene
2017-01-01
The 35th Annual Society of Toxicologic Pathology Symposium, held in June 2016 in San Diego, California, focused on "The Basis and Relevance of Variation in Toxicologic Responses." In order to review the basic tenants of toxicology, a "broad brush" interactive talk that gave an overview of the Cornerstones of Toxicology was presented. The presentation focused on the historical milestones and perspectives of toxicology and through many scientific graphs, data, and real-life examples covered the three basic principles of toxicology that can be summarized, as dose matters (as does timing), people differ, and things change (related to metabolism and biotransformation).
Hayes, A. Wallace; Dixon, Darlene
2016-01-01
The 35th Annual Society of Toxicologic Pathology Symposium, held in June 2016 in San Diego, CA, focused on “The Basis and Relevance of Variation in Toxicologic Responses. In order to review the basic tenants of toxicology a ‘broad brush” interactive talk was presented that gave an overview of the Cornerstones of Toxicology. The presentation focused on the historical milestones and perspectives of toxicology and through many scientific graphs, data, and real-life examples covered the three basic principles of toxicology that can be summarized as dose matters (as does timing), people differ, and things change (related to metabolism and biotransformation). PMID:28068892
10 CFR 60.136 - Preclosure controlled area.
Code of Federal Regulations, 2010 CFR
2010-01-01
... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...
10 CFR 60.136 - Preclosure controlled area.
Code of Federal Regulations, 2011 CFR
2011-01-01
... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...
10 CFR 60.136 - Preclosure controlled area.
Code of Federal Regulations, 2013 CFR
2013-01-01
... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...
10 CFR 60.136 - Preclosure controlled area.
Code of Federal Regulations, 2012 CFR
2012-01-01
... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...
10 CFR 60.136 - Preclosure controlled area.
Code of Federal Regulations, 2014 CFR
2014-01-01
... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...
Timmer-Bonte, J N H; Punt, C J A; vd Heijden, H F M; van Die, C E; Bussink, J; Beijnen, J H; Huitema, A D R; Tjan-Heijnen, V C G
2008-05-01
In advanced non-small cell lung cancer (NSCLC) the clinical benefit of a platinum-based doublet is only modest, therefore, attenuated dosed three-drug combinations are investigated. We hypothesized that with adequate support a full dosed chemotherapy triplet is feasible. The study was designed as a dose finding study of paclitaxel in chemotherapy-naive patients. Paclitaxel was given as a 3-h infusion on day 1, followed by fixed doses of teniposide (or etoposide) 100mg/m(2) days 1, 3, 5 and cisplatin 80 mg/m(2) day 1 every 3 weeks. As myelotoxicity was expected to be the dose-limiting toxicity, prophylactic G-CSF and antibiotic support was evaluated. Indeed, paclitaxel 120 mg/m(2) resulted in dose-limiting neutropenia, despite G-CSF support. Teniposide/etoposide day 1, 3, 5 was less myelotoxic compared to day 1, 2, 3. G-CSF support allowed paclitaxel dose-escalation to 250 mg/m(2). The addition of prophylactic antibiotics enabled dose-escalation to 275 mg/m(2) without reaching MTD. In conclusion, G-CSF and antibiotics prophylaxis enables the delivery of a full dosed chemotherapy triplet in previously untreated NSCLC patients.
Wu, Yue; Gu, Jun-Ming; Huang, Yun; Duan, Yan-Ying; Huang, Rui-Xue; Hu, Jian-An
2016-01-01
Long-term airborne lead exposure, even below official occupational limits, has been found to cause lead poisoning at higher frequencies than expected, which suggests that China’s existing occupational exposure limits should be reexamined. A retrospective cohort study was conducted on 1832 smelting workers from 1988 to 2008 in China. These were individuals who entered the plant and came into continuous contact with lead at work for longer than 3 months. The dose-response relationship between occupational cumulative lead exposure and lead poisoning, abnormal blood lead, urinary lead and erythrocyte zinc protoporphyrin (ZPP) were analyzed and the benchmark dose lower bound confidence limits (BMDLs) were calculated. Statistically significant positive correlations were found between cumulative lead dust and lead fumes exposures and workplace seniority, blood lead, urinary lead and ZPP values. A dose-response relationship was observed between cumulative lead dust or lead fumes exposure and lead poisoning (p < 0.01). The BMDLs of the cumulative occupational lead dust and fumes doses were 0.68 mg-year/m3 and 0.30 mg-year/m3 for lead poisoning, respectively. The BMDLs of workplace airborne lead concentrations associated with lead poisoning were 0.02 mg/m3 and 0.01 mg/m3 for occupational exposure lead dust and lead fume, respectively. In conclusion, BMDLs for airborne lead were lower than occupational exposure limits, suggesting that the occupational lead exposure limits need re-examination and adjustment. Occupational cumulative exposure limits (OCELs) should be established to better prevent occupational lead poisoning. PMID:26999177
Christ, Andreas; Guldimann, René; Bühlmann, Barbara; Zefferer, Marcel; Bakker, Jurriaan F; van Rhoon, Gerard C; Kuster, Niels
2012-12-01
We investigated whether domestic and professional induction cooktops comply with the basic restrictions defined by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). Based on magnetic field measurements, a generic numerical model of an induction cooktop was derived in order to model user exposure. The current density induced in the user was simulated for various models and distances. We also determined the exposure of the fetus and of young children. While most measured cooktops comply with the public exposure limits at the distance specified by the International Electrotechnical Commission (standard IEC 62233), the majority exceeds them at closer distances, some of them even the occupational limits. The maximum current density in the tissue of the user significantly exceeds the basic restrictions for the general public, reaching the occupational level. The exposure of the brains of young children reaches the order of magnitude of the limits for the general public. For a generic worst-case cooktop compliant with the measurement standards, the current density exceeds the 1998 ICNIRP basic restrictions by up to 24 dB or a factor of 16. The brain tissue of young children can be overexposed by 6 dB or a factor of 2. The exposure of the tissue of the central nervous system of the fetus can exceed the limits for the general public if the mother is exposed at occupational levels. This demonstrates that the methodology for testing induction cooktops according to IEC 62233 contradicts the basic restrictions. This evaluation will be extended considering Copyright © 2012 Wiley Periodicals, Inc.
42 CFR 82.2 - What are the basics of dose reconstruction?
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 82.2 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL... conditions and the type, quality, and completeness of data available to characterize the environment. (a) If... information to analytically develop an exposure model. For internal exposures, this model includes such...
This product is a powerpoint presentation. The presentation describes the science of toxicology and basic concepts in dose-response analysis. The presentation provides an example of computational toxicology approaches used to develop toxicity data for thousands of chemicals. The ...
Soil contamination standards for protection of personnel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rittmann, P.D.
1998-04-16
The objective of this report is to recommend soil contamination levels that will ensure that radionuclide intakes by unprotected workers are likely to give internal doses below selected dose limits during the working year. The three internal dose limits are 1, 100, and 500 mrem per year. In addition, photon, beta, and alpha instrument readings are estimated for these soil concentration limits. Two exposure pathways are considered: the first is inhalation of resuspended dust and the second is ingestion of trace amounts of soil. In addition, radioactive decay and ingrowth of progeny during the year of exposure is included. Externalmore » dose from the soil contamination is not included because monitoring and control of external exposures is carried out independently from internal exposures, which are the focus of this report. The methods used are similar to those used by Carbaugh and Bihl (1993) to set bioassay criteria for such workers.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fogh, Shannon; Machtay, Mitchell; Werner-Wasik, Maria
Purpose: Based on preclinical data indicating the radiosensitizing potential of epothilone B, the present study was designed to evaluate the toxicity and response rate of patupilone, an epothilone B, with concurrent radiotherapy (RT) for the treatment of central nervous system malignancies. Methods and Materials: The present Phase I study evaluated the toxicities associated with patupilone combined with RT to establish the maximal tolerated dose. Eligible patients had recurrent gliomas (n = 10) primary (n = 5) or metastatic (n = 17) brain tumors. Dose escalation occurred if no dose-limiting toxicities, defined as any Grade 4-5 toxicity or Grade 3 toxicitymore » requiring hospitalization, occurred during treatment. Results: Of 14 patients, 5 were treated with weekly patupilone at 1.5 mg/m{sup 2}, 4 at 2.0 mg/m{sup 2}, 4 at 2.5 mg/m{sup 2}, and 1 at 4 mg/m{sup 2}. Of 18 patients, 7 were treated in the 6-mg/m{sup 2} group, 6 in the 8-mg/m{sup 2} group, and 5 in the 10-mg/m{sup 2} group. Primary central nervous system malignancies received RT to a median dose of 60 Gy. Central nervous system metastases received whole brain RT to a median dose of 37.4 Gy, and patients with recurrent gliomas underwent stereotactic RT to a median dose of 37.5 Gy. One dose-limiting toxicity (pneumonia) was observed in group receiving 8-mg/m{sup 2} every 3 weeks. At the subsequent dose level (10 mg/m{sup 2}), two Grade 4 dose-limiting toxicities occurred (renal failure and pulmonary hemorrhage); thus, 8 mg/m{sup 2} every 3 weeks was the maximal tolerated dose and the recommended Phase II dose. Conclusion: Combined with a variety of radiation doses and fractionation schedules, concurrent patupilone was well tolerated and safe, with a maximal tolerated dose of 8 mg/m{sup 2} every 3 weeks.« less
Occupational radiation doses during interventional procedures
NASA Astrophysics Data System (ADS)
Nuraeni, N.; Hiswara, E.; Kartikasari, D.; Waris, A.; Haryanto, F.
2016-03-01
Digital subtraction angiography (DSA) is a type of fluoroscopy technique used in interventional radiology to clearly visualize blood vessels in a bony or dense soft tissue environment. The use of DSA procedures has been increased quite significantly in the Radiology departments in various cities in Indonesia. Various reports showed that both patients and medical staff received a noticeable radiation dose during the course of this procedure. A study had been carried out to measure these doses among interventionalist, nurse and radiographer. The results show that the interventionalist and the nurse, who stood quite close to the X-ray beams compared with the radiographer, received radiation higher than the others. The results also showed that the radiation dose received by medical staff were var depending upon the duration and their position against the X-ray beams. Compared tothe dose limits, however, the radiation dose received by all these three medical staff were still lower than the limits.
Amacher, David E
2010-05-15
Biomarkers are biometric measurements that provide critical quantitative information about the biological condition of the animal or individual being tested. In drug safety studies, established toxicity biomarkers are used along with other conventional study data to determine dose-limiting organ toxicity, and to define species sensitivity for new chemical entities intended for possible use as human medicines. A continuing goal of drug safety scientists in the pharmaceutical industry is to discover and develop better trans-species biomarkers that can be used to determine target organ toxicities for preclinical species in short-term studies at dose levels that are some multiple of the intended human dose and again later in full development for monitoring clinical trials at lower therapeutic doses. Of particular value are early, predictive, noninvasive biomarkers that have in vitro, in vivo, and clinical transferability. Such translational biomarkers bridge animal testing used in preclinical science and human studies that are part of subsequent clinical testing. Although suitable for in vivo preclinical regulatory studies, conventional hepatic safety biomarkers are basically confirmatory markers because they signal organ toxicity after some pathological damage has occurred, and are therefore not well-suited for short-term, predictive screening assays early in the discovery-to-development progression of new chemical entities (NCEs) available in limited quantities. Efforts between regulatory agencies and the pharmaceutical industry are underway for the coordinated discovery, qualification, verification and validation of early predictive toxicity biomarkers. Early predictive safety biomarkers are those that are detectable and quantifiable prior to the onset of irreversible tissue injury and which are associated with a mechanism of action relevant to a specific type of potential hepatic injury. Potential drug toxicity biomarkers are typically endogenous macromolecules in biological fluids with varying immunoreactivity which can present bioanalytical challenges when first discovered. The potential success of these efforts is greatly enhanced by recent advances in two closely linked technologies, toxicoproteomics and targeted, quantitative mass spectrometry. This review focuses on the examination of the current status of these technologies as they relate to the discovery and development of novel preclinical biomarkers of hepatotoxicity. A critical assessment of the current literature reveals two distinct lines of safety biomarker investigation, (1) peripheral fluid biomarkers of organ toxicity and (2) tissue or cell-based toxicity signatures. Improved peripheral fluid biomarkers should allow the sensitive detection of potential organ toxicity prior to the onset of overt organ pathology. Advancements in tissue or cell-based toxicity biomarkers will provide sensitive in vitro or ex vivo screening systems based on toxicity pathway markers. An examination of the current practices in clinical pathology and the critical evaluation of some recently proposed biomarker candidates in comparison to the desired characteristics of an ideal toxicity biomarker lead this author to conclude that a combination of selected biomarkers will be more informative if not predictive of potential animal organ toxicity than any single biomarker, new or old. For the practical assessment of combinations of conventional and/or novel toxicity biomarkers in rodent and large animal preclinical species, mass spectrometry has emerged as the premier analytical tool compared to specific immunoassays or functional assays. Selected and multiple reaction monitoring mass spectrometry applications make it possible for this same basic technology to be used in the progressive stages of biomarker discovery, development, and more importantly, routine study applications without the use of specific antibody reagents. This technology combined with other "omics" technologies can provide added selectivity and sensitivity in preclinical drug safety testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amacher, David E.
Biomarkers are biometric measurements that provide critical quantitative information about the biological condition of the animal or individual being tested. In drug safety studies, established toxicity biomarkers are used along with other conventional study data to determine dose-limiting organ toxicity, and to define species sensitivity for new chemical entities intended for possible use as human medicines. A continuing goal of drug safety scientists in the pharmaceutical industry is to discover and develop better trans-species biomarkers that can be used to determine target organ toxicities for preclinical species in short-term studies at dose levels that are some multiple of the intendedmore » human dose and again later in full development for monitoring clinical trials at lower therapeutic doses. Of particular value are early, predictive, noninvasive biomarkers that have in vitro, in vivo, and clinical transferability. Such translational biomarkers bridge animal testing used in preclinical science and human studies that are part of subsequent clinical testing. Although suitable for in vivo preclinical regulatory studies, conventional hepatic safety biomarkers are basically confirmatory markers because they signal organ toxicity after some pathological damage has occurred, and are therefore not well-suited for short-term, predictive screening assays early in the discovery-to-development progression of new chemical entities (NCEs) available in limited quantities. Efforts between regulatory agencies and the pharmaceutical industry are underway for the coordinated discovery, qualification, verification and validation of early predictive toxicity biomarkers. Early predictive safety biomarkers are those that are detectable and quantifiable prior to the onset of irreversible tissue injury and which are associated with a mechanism of action relevant to a specific type of potential hepatic injury. Potential drug toxicity biomarkers are typically endogenous macromolecules in biological fluids with varying immunoreactivity which can present bioanalytical challenges when first discovered. The potential success of these efforts is greatly enhanced by recent advances in two closely linked technologies, toxicoproteomics and targeted, quantitative mass spectrometry. This review focuses on the examination of the current status of these technologies as they relate to the discovery and development of novel preclinical biomarkers of hepatotoxicity. A critical assessment of the current literature reveals two distinct lines of safety biomarker investigation, (1) peripheral fluid biomarkers of organ toxicity and (2) tissue or cell-based toxicity signatures. Improved peripheral fluid biomarkers should allow the sensitive detection of potential organ toxicity prior to the onset of overt organ pathology. Advancements in tissue or cell-based toxicity biomarkers will provide sensitive in vitro or ex vivo screening systems based on toxicity pathway markers. An examination of the current practices in clinical pathology and the critical evaluation of some recently proposed biomarker candidates in comparison to the desired characteristics of an ideal toxicity biomarker lead this author to conclude that a combination of selected biomarkers will be more informative if not predictive of potential animal organ toxicity than any single biomarker, new or old. For the practical assessment of combinations of conventional and/or novel toxicity biomarkers in rodent and large animal preclinical species, mass spectrometry has emerged as the premier analytical tool compared to specific immunoassays or functional assays. Selected and multiple reaction monitoring mass spectrometry applications make it possible for this same basic technology to be used in the progressive stages of biomarker discovery, development, and more importantly, routine study applications without the use of specific antibody reagents. This technology combined with other 'omics' technologies can provide added selectivity and sensitivity in preclinical drug safety testing.« less
Dupuis, L Lee; Sibbald, Cathryn; Schechter, Tal; Ansari, Marc; Gassas, Adam; Théorêt, Yves; Kassir, Nastya; Champagne, Martin A; Doyle, John
2008-05-01
We currently calculate area under the busulfan concentration time curve (AUC) using 7 plasma busulfan concentrations (AUC7) drawn after the first of 16 i.v. busulfan doses given as a 2-hour infusion every 6 hours. The aim of this study was to develop and validate limited sampling strategies (LSSs) using 3 or fewer busulfan concentration values with which to reliably calculate AUC in children undergoing hematopoietic stem cell transplant (HSCT). Children in the development group (44) received i.v. busulfan at Sick Kids; the validation group consisted of 35 children who received care at CHU Ste-Justine. Busulfan doses given and subsequent plasma busulfan concentrations were recorded. LSSs using 1 to 3 concentration-time points were developed using multiple linear regression. LSS were considered to be acceptable when adjusted r(2) > 0.9, mean bias <15% and precision <15%. Extent of agreement between the AUC7 values and the LSS AUC was assessed by the intraclass correlation coefficient (ICC) and Bland-Altman (BA) analysis. Agreement was considered to be excellent when the lower limit of the 95% confidence limit of the ICC exceeded 0.9 and when the limits of agreement in the BA analysis were +/-15% for both AUC and dose. Administration of the theoretic adjusted busulfan doses based on each LSS was simulated and cases where the resulting AUC was >1500 or <900 microM x min were noted. LSSs using 1, 2, or 3 plasma busulfan concentrations were developed that showed excellent agreement with AUC7 and adjusted busulfan doses. In the validation sample, only the 2- and 3-point LSSs demonstrated acceptable precision and lack of bias. LSSs using 2 or 3 plasma busulfan concentrations can be used to reliably estimate busulfan AUC after IV administration in children undergoing HSCT.
10 CFR 835.207 - Occupational dose limits for minors.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Occupational dose limits for minors. 835.207 Section 835.207 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External... to radiation and/or radioactive materials at a DOE activity are 0.1 rem (0.001 Sv) total effective...
10 CFR 835.207 - Occupational dose limits for minors.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Occupational dose limits for minors. 835.207 Section 835.207 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External... to radiation and/or radioactive materials at a DOE activity are 0.1 rem (0.001 Sv) total effective...
10 CFR 835.207 - Occupational dose limits for minors.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Occupational dose limits for minors. 835.207 Section 835.207 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External... to radiation and/or radioactive materials at a DOE activity are 0.1 rem (0.001 Sv) total effective...
10 CFR 835.207 - Occupational dose limits for minors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Occupational dose limits for minors. 835.207 Section 835.207 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External... to radiation and/or radioactive materials at a DOE activity are 0.1 rem (0.001 Sv) total effective...
The Global Challenge in Basic Education: Why Continued Investment in Basic Education Is Important
ERIC Educational Resources Information Center
Mertaugh, Michael T.; Jimenez, Emmanuel Y.; Patrinos, Harry A.
2009-01-01
This paper documents the importance of continued investment in basic education and argues that investments need to be carefully targeted to address the constraints that limit the coverage and quality of education if they are to provide expected benefits. Part I begins with a discussion of the returns to investment in education. Part II then…
Celecoxib interferes to a limited extent with aspirin‐mediated inhibition of platelets aggregation
Ruzov, Mark; Rimon, Gilad; Pikovsky, Oleg
2015-01-01
Aims The aim of the study was to analyze the interaction between celecoxib and low dose aspirin for COX‐1 binding and its consequences on the aspirin‐mediated antiplatelet effects. Methods We investigated ex vivo the interaction between celecoxib and aspirin for COX‐1 binding and measured the resulting antiplatelet effects. We applied mechanism‐based pharmacokinetic−pharmacodynamic (PKPD) modelling to analyze these data and to predict in vivo platelet aggregation for different doses and administration schedules of aspirin and celecoxib. Results The predictions of the PK‐PD model were consistent with results from previous studies that investigated interaction between aspirin and celecoxib. The modelling results indicate that celecoxib can attenuate to a limited extent the in vivo antiplatelet effects of low dose aspirin. The extent of this interaction can be substantial (up to 15% increase in platelet aggregation by 200 mg day−1 celecoxib when combined with low dose aspirin) during the first days of aspirin administration in patients who are already treated with celecoxib, and it cannot be prevented by separate administration of the interacting drugs. Conclusions At the recommended therapeutic doses, celecoxib can attenuate to a limited extent the in vivo antiplatelet effects of low dose aspirin. Patients receiving a combination of low dose aspirin and the recommended doses of celecoxib were not identified to have increased risk of cardiovascular and cerebrovascular events due to competition between these drugs for COX‐1 binding. Interaction between low dose aspirin and other COX‐2 inhibitors and its clinical consequences requires further investigation. PMID:26456703
Wink, Krista C J; Roelofs, Erik; Simone, Charles B; Dechambre, David; Santiago, Alina; van der Stoep, Judith; Dries, Wim; Smits, Julia; Avery, Stephen; Ammazzalorso, Filippo; Jansen, Nicolas; Jelen, Urszula; Solberg, Timothy; de Ruysscher, Dirk; Troost, Esther G C
2018-03-12
To compare dose to organs at risk (OARs) and dose-escalation possibility for 24 stage I non-small cell lung cancer (NSCLC) patients in a ROCOCO (Radiation Oncology Collaborative Comparison) trial. For each patient, 3 photon plans [Intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT) and CyberKnife], a double scattered proton (DSP) and an intensity-modulated carbon-ion (IMIT) therapy plan were created. Dose prescription was 60 Gy (equivalent) in 8 fractions. The mean dose and dose to 2% of the clinical target volume (CTV) were lower for protons and ions compared with IMRT (p < 0.01). Doses to the lungs, heart, and mediastinal structures were lowest with IMIT (p < 0.01), doses to the spinal cord were lowest with DSP (p < 0.01). VMAT and CyberKnife allowed for reduced doses to most OARs compared with IMRT. Dose escalation was possible for 8 patients. Generally, the mediastinum was the primary dose-limiting organ. On average, the doses to the OARs were lowest using particles, with more homogenous CTV doses. Given the ability of VMAT and CyberKnife to limit doses to OARs compared with IMRT, the additional benefit of particles may only be clinically relevant in selected patients and thus should be carefully weighed for every individual patient. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, W F; Tang, S H; Tan, Q; Liu, Y M
2016-08-20
Objective: To investigate radioactive source term dose monitoring and estimation results in a manufacturing enterprise of ion-absorbing type rare earth ore and the possible ionizing radiation dose received by its workers. Methods: Ionizing radiation monitoring data of the posts in the control area and supervised area of workplace were collected, and the annual average effective dose directly estimated or estimated using formulas was evaluated and analyzed. Results: In the control area and supervised area of the workplace for this rare earth ore, α surface contamination activity had a maximum value of 0.35 Bq/cm 2 and a minimum value of 0.01 Bq/cm 2 ; β radioactive surface contamination activity had a maximum value of 18.8 Bq/cm 2 and a minimum value of 0.22 Bq/cm 2 . In 14 monitoring points in the workplace, the maximum value of the annual average effective dose of occupational exposure was 1.641 mSv/a, which did not exceed the authorized limit for workers (5 mSv/a) , but exceeded the authorized limit for general personnel (0.25 mSv/a) . The radionuclide specific activity of ionic mixed rare earth oxides was determined to be 0.9. Conclusion: The annual average effective dose of occupational exposure in this enterprise does not exceed the authorized limit for workers, but it exceeds the authorized limit for general personnel. We should pay attention to the focus of the radiation process, especially for public works radiation.
Miften, Moyed; Olch, Arthur; Mihailidis, Dimitris; Moran, Jean; Pawlicki, Todd; Molineu, Andrea; Li, Harold; Wijesooriya, Krishni; Shi, Jie; Xia, Ping; Papanikolaou, Nikos; Low, Daniel A
2018-04-01
Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review aimed at improving the understanding and consistency of these processes as well as recommendations for methodologies and tolerance limits in patient-specific IMRT QA. The performance of the dose difference/distance-to-agreement (DTA) and γ dose distribution comparison metrics are investigated. Measurement methods are reviewed and followed by a discussion of the pros and cons of each. Methodologies for absolute dose verification are discussed and new IMRT QA verification tools are presented. Literature on the expected or achievable agreement between measurements and calculations for different types of planning and delivery systems are reviewed and analyzed. Tests of vendor implementations of the γ verification algorithm employing benchmark cases are presented. Operational shortcomings that can reduce the γ tool accuracy and subsequent effectiveness for IMRT QA are described. Practical considerations including spatial resolution, normalization, dose threshold, and data interpretation are discussed. Published data on IMRT QA and the clinical experience of the group members are used to develop guidelines and recommendations on tolerance and action limits for IMRT QA. Steps to check failed IMRT QA plans are outlined. Recommendations on delivery methods, data interpretation, dose normalization, the use of γ analysis routines and choice of tolerance limits for IMRT QA are made with focus on detecting differences between calculated and measured doses via the use of robust analysis methods and an in-depth understanding of IMRT verification metrics. The recommendations are intended to improve the IMRT QA process and establish consistent, and comparable IMRT QA criteria among institutions. © 2018 American Association of Physicists in Medicine.
ENHANCED BIODEGRADATION THROUGH IN-SITU AERATION
This presentation provided an overview of enhanced aerobic bioremediation using in-situ aeration or venting. The following topics were covered: (1) Basic discussion on biodegradation and respiration testing; (2) Basic discussion on volatilization, rate-limited mass transport, an...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kubicek, Gregory J.; Werner-Wasik, Maria; Machtay, Mitchell
Purpose: To evaluate the toxicity and response rate of bortezomib with concurrent radiotherapy and temozolomide in the treatment of patients with central nervous system malignancies. Patients and Methods: This open-label, dose-escalation, Phase I clinical study evaluated the safety of three dose levels of intravenously administered bortezomib (0.7, 1.0, and 1.3 mg/m{sup 2}/dose) on Days 1, 4, 8, and 11 of a 21-day cycle, in addition to concurrent radiotherapy and temozolomide at a daily dose of 75 mg/m{sup 2} starting on Day 1. The primary endpoint was dose-limiting toxicity, defined as any Grade 4-5 toxicity or Grade 3 toxicity directly attributablemore » to protocol treatment, requiring hospitalization and/or radiotherapy interruption. The secondary endpoints included feasibility, non-dose-limiting toxicity, and treatment response. Results: A total of 27 patients were enrolled, 23 of whom had high-grade glioma (10 recurrent and 13 newly diagnosed). No dose-limiting toxicities were noted in any dose group, including the highest (1.3 mg/m{sup 2}/dose). The most frequent toxicities were Grade 1 and 2 stomatitis, erythema, and alopecia. All 27 patients were evaluable for response. At a median follow-up of 15.0 months, 9 patients were still alive, with a median survival of 17.4 months for all patients and 15.0 months for patients with high-grade glioma. Conclusion: Bortezomib administered at its typical 'systemic' dose (1.3 mg/m{sup 2}) is well tolerated and safe combined with temozolomide and radiotherapy when used in the treatment of central nervous system malignancies. A Phase II study to characterize efficacy is warranted.« less
Radiation dose to workers due to the inhalation of dust during granite fabrication.
Zwack, L M; McCarthy, W B; Stewart, J H; McCarthy, J F; Allen, J G
2014-03-01
There has been very little research conducted to determine internal radiation doses resulting from worker exposure to ionising radiation in granite fabrication shops. To address this issue, we estimated the effective radiation dose of granite workers in US fabrication shops who were exposed to the maximum respirable dust and silica concentrations allowed under current US regulations, and also to concentrations reported in the literature. Radiation doses were calculated using standard methods developed by the International Commission on Radiological Protection. The calculated internal doses were very low, and below both US occupational standards (50 mSv yr(-1)) and limits applicable to the general public (1 mSv yr(-1)). Workers exposed to respirable granite dust concentrations at the US Occupational Safety and Health Administration (OSHA) respirable dust permissible exposure limit (PEL) of 5 mg m(-3) over a full year had an estimated radiation dose of 0.062 mSv yr(-1). Workers exposed to respirable granite dust concentrations at the OSHA silica PEL and at the American Conference of Governmental Industrial Hygienists Threshold Limit Value for a full year had expected radiation doses of 0.007 mSv yr(-1) and 0.002 mSv yr(-1), respectively. Using data from studies of respirable granite dust and silica concentrations measured in granite fabrication shops, we calculated median expected radiation doses that ranged from <0.001 to 0.101 mSv yr(-1).
Study of natural radioactivity in Mansehra granite, Pakistan: environmental concerns.
Qureshi, Aziz Ahmed; Jadoon, Ishtiaq Ahmed Khan; Wajid, Ali Abbas; Attique, Ahsan; Masood, Adil; Anees, Muhammad; Manzoor, Shahid; Waheed, Abdul; Tubassam, Aneela
2014-03-01
A part of Mansehra Granite was selected for the assessment of radiological hazards. The average activity concentrations of (226)Ra, (232)Th and (40)K were found to be 27.32, 50.07 and 953.10 Bq kg(-1), respectively. These values are in the median range when compared with the granites around the world. Radiological hazard indices and annual effective doses were estimated. All of these indices were found to be within the criterion limits except outdoor external dose (82.38 nGy h(-1)) and indoor external dose (156.04 nGy h(-1)), which are higher than the world's average background levels of 51 and 55 nGy h(-1), respectively. These values correspond to an average annual effective dose of 0.867 mSv y(-1), which is less than the criterion limit of 1 mSv y(-1) (ICRP-103). Some localities in the Mansehra city have annual effective dose higher than the limit of 1 mSv y(-1). Overall, the Mansehra Granite does not pose any significant radiological health hazard in the outdoor or indoor.
Performance Characteristics of an Independent Dose Verification Program for Helical Tomotherapy
Chang, Isaac C. F.; Chen, Jeff; Yartsev, Slav
2017-01-01
Helical tomotherapy with its advanced method of intensity-modulated radiation therapy delivery has been used clinically for over 20 years. The standard delivery quality assurance procedure to measure the accuracy of delivered radiation dose from each treatment plan to a phantom is time-consuming. RadCalc®, a radiotherapy dose verification software, has released specifically for beta testing a module for tomotherapy plan dose calculations. RadCalc®'s accuracy for tomotherapy dose calculations was evaluated through examination of point doses in ten lung and ten prostate clinical plans. Doses calculated by the TomoHDA™ tomotherapy treatment planning system were used as the baseline. For lung cases, RadCalc® overestimated point doses in the lung by an average of 13%. Doses within the spinal cord and esophagus were overestimated by 10%. Prostate plans showed better agreement, with overestimations of 6% in the prostate, bladder, and rectum. The systematic overestimation likely resulted from limitations of the pencil beam dose calculation algorithm implemented by RadCalc®. Limitations were more severe in areas of greater inhomogeneity and less prominent in regions of homogeneity with densities closer to 1 g/cm3. Recommendations for RadCalc® dose calculation algorithms and anatomical representation were provided based on the results of the study. PMID:28974862
High-Dose Atomoxetine Treatment of ADHD in Youths with Limited Response to Standard Doses
ERIC Educational Resources Information Center
Kratochvil, Christopher J.; Michelson, David; Newcorn, Jeffrey H.; Weiss, Margaret D.; Busner, Joan; Moore, Rodney J.; Ruff, Dustin D.; Ramsey, Janet; Dickson, Ruth; Turgay, Atilla; Saylor, Keith E.; Luber, Stephen; Vaughan, Brigette; Allen, Albert J.
2007-01-01
Objective: To assess the utility and tolerability of higher than standard atomoxetine doses to treat attention-deficit/hyperactivity disorder (ADHD). Method: Two randomized, double-blind trials of atomoxetine nonresponders ages 6 to 16 years were conducted comparing continued treatment with same-dose atomoxetine to treatment using greater than…
A new structure design and the basic radiation characteristics test of the intense current tube
NASA Astrophysics Data System (ADS)
Li, Zhiyuan; Ai, Xianyun; Fu, Li; Cui, Hui
2018-02-01
As a kind of special G-M counter, the intense current tube (ICT) is characterized by small ratio of cathode to anode radius, high working current or count rate, and can be used as the detection units of ultra-high range radiation instruments. In this paper, a new design of ICT structure is introduced, not only does it have a minimum ratio of cathode to anode but it also has a cathode which directly sticks out from the sensitive gas. Using COMSOL Multiphysics, we simulated the electric field between the anode and cathode and finalized the optimal structure. The results of processes and experiments show that the structure has better properties, with plateau slope reaching up to 7.4% within 100V, and it also has a wider range of dose rate. The linear data between the bottom limit of 0.2mGy/h and the upper limit of 1Gy/h is quite accurate but it becomes less reliable beyond 1Gy/h. By using Paralyzable model, we deduce that the dead time of the said ICT is less than 13.4 µs, and we will further optimize the readout circuit in order to reduce the resolution time of the circuit in the near future.
Methods and applications of HPLC-AMS (WBio 5)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bucholz, B A; Clifford, A J; Duecker, S R
Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a {sup 14}C-labelled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the {sup 14}C content above the control predose tissue and converting to equivalents of the parent compound. High Performance Liquid Chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement.more » Unknowns are identified by coelution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the {sup 14}C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of {sup 14}C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected {sup 14}C activity <0.17 Bq (4.5 pCi) on the HPLC column.« less
Diagnosis and management of von Willebrand disease: a developing country perspective.
Nair, Sukesh Chandran; Viswabandya, Auro; Srivastava, Alok
2011-07-01
Special challenges exist in the management of patients with von Willebrand disease (VWD) because of limitations in diagnostic facilities and therapeutic options. However, even within these limitations, it is possible to establish comprehensive services for this condition. Our data show that among 202 patients with VWD, 107 were type 3, 62 were type 1, and the others different categories of type 2. Basic tests such as bleeding time and activated partial thromboplastin time with factor (F)VIII coagulant are able to diagnose most of those with severe disease. We have been able to adapt the specific tests such as von Willebrand factor (VWF) ristocetin cofactor and VWF antigen from the tedious batched manual methods to cost-effective automated methods on advanced coagulometers. Discriminatory tests such as VWF collagen binding, VWF:FVIIIB, ristocetin-induced platelet agglutination (RIPA) are done in batches. Therapeutic options and for the treatment of bleeding include desmopressin, cryoprecipitate, and intermediate purity VWF-containing clotting factor concentrates. Tranexamic acid is also widely used as well as hormonal therapy for menorrhagia. We have also shown that modest doses of intermediate purity FVIII (Koate DVI; Talecris Biotherapeutics, Raleigh, NC, USA) at 35 IU/kg preoperatively and 10 to 20 IU/kg after that are sufficient for surgical hemostasis in these patients. © Thieme Medical Publishers.
Zorko, Benjamin; Korun, Matjaž; Mora Canadas, Juan Carlos; Nicoulaud-Gouin, Valerie; Chyly, Pavol; Blixt Buhr, Anna Maria; Lager, Charlotte; Aquilonius, Karin; Krajewski, Pawel
2016-07-01
Several methods for reporting outcomes of gamma-ray spectrometric measurements of environmental samples for dose calculations are presented and discussed. The measurement outcomes can be reported as primary measurement results, primary measurement results modified according to the quantification limit, best estimates obtained by the Bayesian posterior (ISO 11929), best estimates obtained by the probability density distribution resembling shifting, and the procedure recommended by the European Commission (EC). The annual dose is calculated from the arithmetic average using any of these five procedures. It was shown that the primary measurement results modified according to the quantification limit could lead to an underestimation of the annual dose. On the other hand the best estimates lead to an overestimation of the annual dose. The annual doses calculated from the measurement outcomes obtained according to the EC's recommended procedure, which does not cope with the uncertainties, fluctuate between an under- and overestimation, depending on the frequency of the measurement results that are larger than the limit of detection. In the extreme case, when no measurement results above the detection limit occur, the average over primary measurement results modified according to the quantification limit underestimates the average over primary measurement results for about 80%. The average over best estimates calculated according the procedure resembling shifting overestimates the average over primary measurement results for 35%, the average obtained by the Bayesian posterior for 85% and the treatment according to the EC recommendation for 89%. Copyright © 2016 Elsevier Ltd. All rights reserved.
EPA's Benchmark Dose Modeling Software
The EPA developed the Benchmark Dose Software (BMDS) as a tool to help Agency risk assessors facilitate applying benchmark dose (BMD) method’s to EPA’s human health risk assessment (HHRA) documents. The application of BMD methods overcomes many well know limitations ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kairn, Tanya, E-mail: t.kairn@gmail.com; School of Chemistry, Physics, and Mechanical Engineering, Queensland University of Technology, Brisbane; Papworth, Daniel
2016-10-01
Cancer often metastasizes to the vertebra, and such metastases can be treated successfully using simple, static posterior or opposed-pair radiation fields. However, in some cases, including when re-irradiation is required, spinal cord avoidance becomes necessary and more complex treatment plans must be used. This study evaluated 16 sample intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans designed to treat 6 typical vertebral and paraspinal volumes using a standard prescription, with the aim of investigating the advantages and limitations of these treatment techniques and providing recommendations for their optimal use in vertebral treatments. Treatment plan quality and beammore » complexity metrics were evaluated using the Treatment And Dose Assessor (TADA) code. A portal-imaging–based quality assurance (QA) system was used to evaluate treatment delivery accuracy, and radiochromic film measurements were used to provide high-resolution verification of treatment plan dose accuracy, especially in the steep dose gradient regions between each vertebral target and spinal cord. All treatment modalities delivered approximately the same doses and the same levels of dose heterogeneity to each planning target volume (PTV), although the minimum PTV doses in the vertebral plans were substantially lower than the prescription, because of the requirement that the plans meet a strict constraint on the dose to the spinal cord and cord planning risk volume (PRV). All plans met required dose constraints on all organs at risk, and all measured PTV-cord dose gradients were steeper than planned. Beam complexity analysis suggested that the IMRT treatment plans were more deliverable (less complex, leading to greater QA success) than the VMAT treatment plans, although the IMRT plans also took more time to deliver. The accuracy and deliverability of VMAT treatment plans were found to be substantially increased by limiting the number of monitor units (MU) per beam at the optimization stage, and thereby limiting beam modulation complexity. The VMAT arcs that were optimized with MU limitation had higher QA pass rates as well as higher modulation complexity scores (less complexity), lower modulation indices (less modulation), lower MU per beam, larger beam segments, and fewer small apertures than the VMAT arcs that were optimized without MU limitation. It is recommended that VMAT treatments for vertebral volumes, where the PTV abuts or surrounds the spinal cord, should be optimized with MU limitation. IMRT treatments may be preferable to the VMAT treatments, for dosimetry and deliverability reasons, but may be inappropriate for some patients because of their increased treatment delivery time.« less
Postel-Vinay, Sophie; Collette, Laurence; Paoletti, Xavier; Rizzo, Elisa; Massard, Christophe; Olmos, David; Fowst, Camilla; Levy, Bernard; Mancini, Pierre; Lacombe, Denis; Ivy, Percy; Seymour, Lesley; Le Tourneau, Christophe; Siu, Lillian L; Kaye, Stan B; Verweij, Jaap; Soria, Jean-Charles
2014-08-01
Traditional dose-limiting toxicity (DLT) definition, which uses grade (G) 3-4 toxicity data from cycle 1 (C1) only, may not be appropriate for molecularly targeted agents (MTAs) of prolonged administration, for which late or lower grade toxicities also deserve attention. In collaboration with pharmaceutical companies and academia, an European Organisation for Research and Treatment of Cancer (EORTC)-led initiative, Dose-Limiting Toxicity and Toxicity Assessment Recommendation Group for Early Trials of Targeted therapies (DLT-TARGETT), collected data from completed phase 1 trials evaluating MTAs as monotherapy. All toxicities at least possibly related to the study drugs that occurred during C1-6, their type, grade (CTCAEv3.0), and duration as well as patients' relative dose-intensity (RDI), were recorded. The 54 eligible trials enrolled 2084 evaluable adult patients with solid tumours between 1999 and 2013, and evaluated small molecules (40), antibodies (seven), recombinant peptides (five) and antisense oligodeoxynucleotides (two). A maximum tolerated dose was set in 43 trials. Fifteen percent of the patients received <75% of the intended RDI in C1, but only 9.1% of them presented protocol-defined DLTs. After C1, 16-19% of patients received <75% of the intended RDI. A similar proportion of G ⩾ 3 toxicities was recorded in C1 and after C1 (936 and 1087 toxicities, respectively), with the first G⩾3 toxicity occurring after C1 in 18.6% of patients. Although protocol-defined DLT period is traditionally limited to C1, almost 20% of patients present significant reductions in RDI at any time in phase 1 trials of MTAs. Recommended phase 2 dose assessment should incorporate all available information from any cycle (notably lower grade toxicities leading to such RDI decrease), and be based on achieving >75% RDI. Copyright © 2014 Elsevier Ltd. All rights reserved.
The Effect of Intra-articular Corticosteroids on Articular Cartilage
Wernecke, Chloe; Braun, Hillary J.; Dragoo, Jason L.
2015-01-01
Background: Intra-articular (IA) corticosteroid therapy has been used for the treatment of inflammation and pain in the knee since the 1950s. Purpose: To review the current literature on the effects of IA corticosteroids on articular cartilage. Study Design: Systematic review. Methods: A MEDLINE and SCOPUS database search was performed, and studies were selected for basic science and clinical trial research on corticosteroids with direct outcome measures of cartilage health. Preliminary searches yielded 1929 articles, and final analysis includes 40 studies. Results: Methylprednisolone, dexamethasone, hydrocortisone, betamethasone, prednisolone, and triamcinolone were reported to display dose-dependent deleterious effects on cartilage morphology, histology, and viability in both in vitro and in vivo models. The beneficial animal in vivo effects of methylprednisolone, hydrocortisone, and triamcinolone occurred at low doses (usually <2-3 mg/dose or 8-12 mg/cumulative total dose in vivo), at which increased cell growth and recovery from damage was observed; the single human clinical trial indicated a beneficial effect of triamcinolone. However, at higher doses (>3 mg/dose or 18-24 mg/cumulative total dose in vivo), corticosteroids were associated with significant gross cartilage damage and chondrocyte toxicity. Dose and time dependency of corticosteroid chondrotoxicity was supported in the in vitro results, however, without clear dose thresholds. Conclusion: Corticosteroids have a time- and dose-dependent effect on articular cartilage, with beneficial effects occurring at low doses and durations and detrimental effects at high doses and durations. Clinically, beneficial effects are supported for IA administration, but the lowest efficacious dose should be used. PMID:26674652
COMPARTMENTALIZED PHANTOMS FOR THE STANDARD MAN, ADOLESCENT AND CHILD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayes, R.L.; Brucer, M.
A compartmentalized phantom for the standard man was designed and built of readily available and inexpensive materials. Similar phantoms were also designed for an adolescent and a child. The basic emphasis in the designs is on general utility so that a variety of different dosemeasurement techniques could be used on the same phantom. The designs are, however, in reasonable agreement with authropometric data reported in the literature. The phantoms proved to be extremely useful in depth-dose and energy-absorption measurements for total-body irradiation therapy. Dose measurements with beam teletherapy, brachytherapy devices, and internally distributed radioisotopes were also made. (auth)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pageau, R.; St-Pierre, C.
1978-10-01
Rats fed laboratory chow or elemental diet 3 were given fractions of 240 rads of /sup 60/Co ..gamma.. radiation abdominally (1200 rads/week) until all animals had died. Changes in appetite, body weight, and mortality were monitored as a function of the cumulative dose received. More radiation was needed in the diet-fed group to achieve both 0 and 100% mortality, a difference of 37% at the mean lethal dose level. Both groups developed similar progressive anorexia but the diet-fed animals lost weight more slowly. Data indicate that basic intestinal radioresistance is enhanced by feeding the elemental diet.
Cost of goods sold and total cost of delivery for oral and parenteral vaccine packaging formats.
Sedita, Jeff; Perrella, Stefanie; Morio, Matt; Berbari, Michael; Hsu, Jui-Shan; Saxon, Eugene; Jarrahian, Courtney; Rein-Weston, Annie; Zehrung, Darin
2018-03-14
Despite limitations of glass packaging for vaccines, the industry has been slow to implement alternative formats. Polymer containers may address many of these limitations, such as breakage and delamination. However, the ability of polymer containers to achieve cost of goods sold (COGS) and total cost of delivery (TCOD) competitive with that of glass containers is unclear, especially for cost-sensitive low- and lower-middle-income countries. COGS and TCOD models for oral and parenteral vaccine packaging formats were developed based on information from subject matter experts, published literature, and Kenya's comprehensive multiyear plan for immunization. Rotavirus and inactivated poliovirus vaccines (IPV) were used as representative examples of oral and parenteral vaccines, respectively. Packaging technologies evaluated included glass vials, blow-fill-seal (BFS) containers, preformed polymer containers, and compact prefilled auto-disable (CPAD) devices in both BFS and preformed formats. For oral vaccine packaging, BFS multi-monodose (MMD) ampoules were the least expensive format, with a COGS of $0.12 per dose. In comparison, oral single-dose glass vials had a COGS of $0.40. BFS MMD ampoules had the lowest TCOD of oral vaccine containers at $1.19 per dose delivered, and ten-dose glass vials had a TCOD of $1.61 per dose delivered. For parenteral vaccines, the lowest COGS was achieved with ten-dose glass vials at $0.22 per dose. In contrast, preformed CPAD devices had the highest COGS at $0.60 per dose. Ten-dose glass vials achieved the lowest TCOD of the parenteral vaccine formats at $1.56 per dose delivered. Of the polymer containers for parenteral vaccines, BFS MMD ampoules achieved the lowest TCOD at $1.89 per dose delivered, whereas preformed CPAD devices remained the most expensive format, at $2.25 per dose delivered. Given their potential to address the limitations of glass and reduce COGS and TCOD, polymer containers deserve further consideration as alternative approaches for vaccine packaging. Copyright © 2018 PATH. Published by Elsevier Ltd.. All rights reserved.
Guan, Fada; Peeler, Christopher; Bronk, Lawrence; Geng, Changran; Taleei, Reza; Randeniya, Sharmalee; Ge, Shuaiping; Mirkovic, Dragan; Grosshans, David; Mohan, Radhe; Titt, Uwe
2015-01-01
Purpose: The motivation of this study was to find and eliminate the cause of errors in dose-averaged linear energy transfer (LET) calculations from therapeutic protons in small targets, such as biological cell layers, calculated using the geant 4 Monte Carlo code. Furthermore, the purpose was also to provide a recommendation to select an appropriate LET quantity from geant 4 simulations to correlate with biological effectiveness of therapeutic protons. Methods: The authors developed a particle tracking step based strategy to calculate the average LET quantities (track-averaged LET, LETt and dose-averaged LET, LETd) using geant 4 for different tracking step size limits. A step size limit refers to the maximally allowable tracking step length. The authors investigated how the tracking step size limit influenced the calculated LETt and LETd of protons with six different step limits ranging from 1 to 500 μm in a water phantom irradiated by a 79.7-MeV clinical proton beam. In addition, the authors analyzed the detailed stochastic energy deposition information including fluence spectra and dose spectra of the energy-deposition-per-step of protons. As a reference, the authors also calculated the averaged LET and analyzed the LET spectra combining the Monte Carlo method and the deterministic method. Relative biological effectiveness (RBE) calculations were performed to illustrate the impact of different LET calculation methods on the RBE-weighted dose. Results: Simulation results showed that the step limit effect was small for LETt but significant for LETd. This resulted from differences in the energy-deposition-per-step between the fluence spectra and dose spectra at different depths in the phantom. Using the Monte Carlo particle tracking method in geant 4 can result in incorrect LETd calculation results in the dose plateau region for small step limits. The erroneous LETd results can be attributed to the algorithm to determine fluctuations in energy deposition along the tracking step in geant 4. The incorrect LETd values lead to substantial differences in the calculated RBE. Conclusions: When the geant 4 particle tracking method is used to calculate the average LET values within targets with a small step limit, such as smaller than 500 μm, the authors recommend the use of LETt in the dose plateau region and LETd around the Bragg peak. For a large step limit, i.e., 500 μm, LETd is recommended along the whole Bragg curve. The transition point depends on beam parameters and can be found by determining the location where the gradient of the ratio of LETd and LETt becomes positive. PMID:26520716
Masuda, Norikazu; Iwata, Hiroji; Aogi, Kenjiro; Xu, Yihuan; Ibrahim, Ayman; Gao, Ling; Dalal, Rita; Yoshikawa, Reigetsu; Sasaki, Yasutsuna
2016-12-01
The primary objective of this study was to investigate the safety and tolerability and to confirm the recommended dose of the anti-vascular endothelial growth factor receptor 2 monoclonal antibody ramucirumab in combination with docetaxel in Japanese patients with metastatic/locally advanced breast cancer. In this multicenter, single-arm, Phase Ib trial, eligibility criteria included: 20 years or older, Eastern Cooperative Oncology Group performance status of 0/1 and confirmed diagnosis of human epidermal growth factor receptor 2-negative metastatic/locally recurrent inoperable breast adenocarcinoma. Patients received docetaxel (75 mg/m 2 ) followed by ramucirumab (10 mg/kg) on Day 1 of 21-day cycles. Recommended dose was defined as <33% dose-limiting toxicities in dose-limiting toxicity-evaluable patients in Cycle 1. The safety, pharmacokinetics, immunogenicity and antitumor activity were examined. Seven patients were treated. Most adverse events were mild to moderate. Two patients during Cycle 1 experienced a dose-limiting toxicity; one patient each experienced Grade 3 febrile neutropenia and Grade 3 gingivitis. Both dose-limiting toxicities subsequently resolved. No patients discontinued study therapies during Cycle 1. Four serious adverse events were possibly related to ramucirumab in combination with docetaxel. Anti-ramucirumab antibodies were not detected. Pharmacokinetic analysis revealed low total body clearance and long apparent terminal elimination half-life (~7-12 days). Partial response was reported in four patients. The combination of ramucirumab and docetaxel was tolerable in female Japanese patients with breast cancer. Ramucirumab 10 mg/kg in combination with docetaxel (75 mg/m 2 ) was confirmed as the recommended dose among Japanese patients, supporting its use in future studies. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Normal tissue toxicity after small field hypofractionated stereotactic body radiation.
Milano, Michael T; Constine, Louis S; Okunieff, Paul
2008-10-31
Stereotactic body radiation (SBRT) is an emerging tool in radiation oncology in which the targeting accuracy is improved via the detection and processing of a three-dimensional coordinate system that is aligned to the target. With improved targeting accuracy, SBRT allows for the minimization of normal tissue volume exposed to high radiation dose as well as the escalation of fractional dose delivery. The goal of SBRT is to minimize toxicity while maximizing tumor control. This review will discuss the basic principles of SBRT, the radiobiology of hypofractionated radiation and the outcome from published clinical trials of SBRT, with a focus on late toxicity after SBRT. While clinical data has shown SBRT to be safe in most circumstances, more data is needed to refine the ideal dose-volume metrics.
Is Sustainability Achievable? Exploring the Limits of Sustainability with Model Systems
Successful implementation of sustainability ideas in ecosystem management requires a basic understanding of the often nonlinear and non-intuitive relationships amongst different dimensions of sustainability, particularly the systemwide implications of human actions. This basic un...
Yang, Xiaoxia; Li, Yanhui; Du, Qiuju; Sun, Jiankun; Chen, Long; Hu, Song; Wang, Zonghua; Xia, Yanzhi; Xia, Linhua
2015-09-01
Novel anionic polyacrylamide/graphene oxide aerogels were prepared by a freeze drying method and used to remove basic fuchsin from aqueous solutions. These aerogels were sponge-like solid with lightweight, fluffy and porous structure. The batch adsorption experiments were carried out to study the effect of various parameters, such as the solution pH, adsorbent dose, contact time and temperature on adsorption properties of basic fuchsin onto anionic polyacrylamide/graphene oxide aerogels. The kinetics of adsorption corresponded to the pseudo-second-order kinetic model. The Langmuir adsorption isotherm was suitable to describe the equilibrium adsorption process. The maximum adsorption capacity was up to 1034.3 mg/g, which indicated that anionic polyacrylamide/graphene oxide aerogels were promising adsorbents for removing dyes pollutants from aqueous solution. Copyright © 2015 Elsevier Inc. All rights reserved.
Pasternack, Jordan B.; Howell, Roger W.
2012-01-01
The temporal variations in absorbed dose rates to organs and tissues in the body are very large in diagnostic and therapeutic nuclear medicine. The response of biological endpoints of relevance to radiation safety and therapeutic efficacy are generally modulated by dose rate. Therefore, it is important to understand how the complex dose rate patterns encountered in nuclear medicine impact relevant biological responses. Accordingly, a graphical user interface (GUI) was created to control a cesium-137 irradiator to deliver such dose rate patterns. Methods Visual Basic 6.0 was used to create a user-friendly GUI to control the dose rate by varying the thickness of a mercury attenuator. The GUI facilitates the delivery of a number of dose rate patterns including constant, exponential increase or decrease, and multi-component exponential. Extensive visual feedback is provided by the GUI during both the planning and delivery stages. Results The GUI controlled irradiator can achieve a maximum dose rate of 40 cGy/hr and a minimum dose rate of 0.01 cGy/hr. Addition of machined lead blocks can be used to further reduce the minimum dose rate to 0.0001 cGy/hr. Measured dose rate patterns differed from programmed dose rate patterns in total dose by 3.2% to 8.4%. Conclusion The GUI controlled irradiator is able to accurately create dose rate patterns encountered in nuclear medicine and other related fields. This makes it an invaluable tool for studying the effects of chronic constant and variable low dose rates on biological tissues in the contexts of both radiation protection and clinical administration of internal radionuclides. PMID:23265668
Pasternack, Jordan B; Howell, Roger W
2013-02-01
The temporal variations in absorbed dose rates to organs and tissues in the body are very large in diagnostic and therapeutic nuclear medicine. The response of biological endpoints of relevance to radiation safety and therapeutic efficacy is generally modulated by dose rate. Therefore, it is important to understand how the complex dose rate patterns encountered in nuclear medicine impact relevant biological responses. Accordingly, a graphical user interface (GUI) was created to control a cesium-137 irradiator to deliver such dose rate patterns. Visual Basic 6.0 was used to create a user-friendly GUI to control the dose rate by varying the thickness of a mercury attenuator. The GUI facilitates the delivery of a number of dose rate patterns including constant, exponential increase or decrease, and multi-component exponential. Extensive visual feedback is provided by the GUI during both the planning and delivery stages. The GUI controlled irradiator can achieve a maximum dose rate of 40 cGy/h and a minimum dose rate of 0.01 cGy/h. Addition of machined lead blocks can be used to further reduce the minimum dose rate to 0.0001 cGy/h. Measured dose rate patterns differed from programmed dose rate patterns in total dose by 3.2% to 8.4%. The GUI controlled irradiator is able to accurately create dose rate patterns encountered in nuclear medicine and other related fields. This makes it an invaluable tool for studying the effects of chronic constant and variable low dose rates on biological tissues in the contexts of both radiation protection and clinical administration of internal radionuclides. Copyright © 2013 Elsevier Inc. All rights reserved.
A Phase I study of bizelesin (NSC 615291) in patients with advanced solid tumors.
Pitot, Henry C; Reid, Joel M; Sloan, Jeff A; Ames, Matthew M; Adjei, Alex A; Rubin, Joseph; Bagniewski, Pamela G; Atherton, Pamela; Rayson, Daniel; Goldberg, Richard M; Erlichman, Charles
2002-03-01
To evaluate the toxicities, characterize the pharmacokinetics, and determine the maximum-tolerated dose of bizelesin administered once every 4 weeks. Patients with advanced solid tumors received escalating doses of bizelesin as an i.v. push every 4 weeks. Pharmacokinetic studies were performed with the first treatment cycle. Nineteen eligible patients received a total of 54 courses of bizelesin at doses ranging from 0.1 to 1 microg/m(2). Dose-limiting toxicity of neutropenia was seen in 2 of 4 patients treated at the 1 microg/m(2) dose level. Nonhematological toxicity was generally mild with maximum toxicity being
Dupuis, Jehan; Morschhauser, Franck; Ghesquières, Hervé; Tilly, Hervé; Casasnovas, Olivier; Thieblemont, Catherine; Ribrag, Vincent; Bossard, Céline; Le Bras, Fabien; Bachy, Emmanuel; Hivert, Bénédicte; Nicolas-Virelizier, Emmanuelle; Jardin, Fabrice; Bastie, Jean-Noel; Amorim, Sandy; Lazarovici, Julien; Martin, Antoine; Coiffier, Bertrand
2015-04-01
Romidepsin is a histone deacetylase inhibitor approved in the USA for patients with recurrent or refractory peripheral T-cell lymphoma and has shown activity in this setting with mainly haematological and gastrointestinal toxicity. Although it has limited efficacy, cyclophosphamide, doxorubicin, vincristine, and prednisone (CHOP) therapy is widely used for treatment of de-novo peripheral T-cell lymphoma. We aimed to assess the safety, tolerability, and activity of romidepsin combined with CHOP in patients with previously untreated disease. We enrolled patients aged 18-80 years with histologically proven, previously untreated, peripheral T-cell lymphoma (Eastern Cooperative Oncology Group performance status ≤2) into a dose-escalation (phase 1b) and expansion (phase 2) study at nine Lymphoma Study Association centres in France. In the dose-escalation phase, we allocated consecutive blocks of three participants to receive eight 3 week cycles of CHOP (intravenous cyclophosphamide 750 mg/m(2), doxorubicin 50 mg/m(2), and vincristine 1.4 mg/m(2) [maximum 2 mg] on day 1 and oral prednisone 40 mg/m(2) on days 1-5) in association with varying doses of romidepsin. The starting dose was 10 mg/m(2) intravenously on days 1 and 8 of each cycle, and we used a 3 + 3 design. We assessed dose-limiting toxicities only during the first two cycles. The primary endpoint was to determine the recommended dose for the combination. For the phase 2 study, we aimed to increase the cohort of patients receiving the recommended dose to a total of 25 patients. Patients were assessed for safety outcomes at least twice per cycle according to the Common Terminology Criteria for Adverse Events, version 4.0. Safety analyses included all patients who received at least one dose of romidepsin and CHOP. This trial is registered at the European Clinical Trials Database (EudraCT), number 2010-020962-91 and ClinicalTrials.gov, number NCT01280526. Between Jan 13, 2011, and May 21, 2013, we enrolled 37 patients (18 treated in phase 1b and 19 patients in phase 2). Three of six patients initially treated at 10 mg/m(2) had a dose-limiting toxicity. The dose-escalation committee decided to modify the study protocol to redefine dose-limiting toxicities with regard to haematological toxicity. Three patients were treated with 8 mg/m(2) of romidepsin, an additional three at 10 mg/m(2) (one dose-limiting toxicity), and six patients at 12 mg/m(2) (three dose-limiting toxicities). We chose romidepsin 12 mg/m(2) as the recommended dose for phase 2. Of the 37 patients treated, three had early cardiac events (two myocardial infarctions and one acute cardiac failure). No deaths were attributable to toxicity. 25 (68%) of 37 patients had at least one serious adverse event. Overall, the most frequent serious adverse events were febrile neutropenia (five [14%] of 37 patients), physical health deterioration (five [14%]), lung infection (four [11%]), and vomiting (three [8%]). 33 (89%) of patients had grade 3-4 neutropenia, and 29 (78%) had grade 3-4 thrombocytopenia. Romidepsin can be combined with CHOP but this combination should now be tested in comparison to CHOP alone in a randomised trial. Celgene. Copyright © 2015 Elsevier Ltd. All rights reserved.
Dose Equivalents for Second-Generation Antipsychotic Drugs: The Classical Mean Dose Method
Leucht, Stefan; Samara, Myrto; Heres, Stephan; Patel, Maxine X.; Furukawa, Toshi; Cipriani, Andrea; Geddes, John; Davis, John M.
2015-01-01
Background: The concept of dose equivalence is important for many purposes. The classical approach published by Davis in 1974 subsequently dominated textbooks for several decades. It was based on the assumption that the mean doses found in flexible-dose trials reflect the average optimum dose which can be used for the calculation of dose equivalence. We are the first to apply the method to second-generation antipsychotics. Methods: We searched for randomized, double-blind, flexible-dose trials in acutely ill patients with schizophrenia that examined 13 oral second-generation antipsychotics, haloperidol, and chlorpromazine (last search June 2014). We calculated the mean doses of each drug weighted by sample size and divided them by the weighted mean olanzapine dose to obtain olanzapine equivalents. Results: We included 75 studies with 16 555 participants. The doses equivalent to 1 mg/d olanzapine were: amisulpride 38.3 mg/d, aripiprazole 1.4 mg/d, asenapine 0.9 mg/d, chlorpromazine 38.9 mg/d, clozapine 30.6 mg/d, haloperidol 0.7 mg/d, quetiapine 32.3mg/d, risperidone 0.4mg/d, sertindole 1.1 mg/d, ziprasidone 7.9 mg/d, zotepine 13.2 mg/d. For iloperidone, lurasidone, and paliperidone no data were available. Conclusions: The classical mean dose method is not reliant on the limited availability of fixed-dose data at the lower end of the effective dose range, which is the major limitation of “minimum effective dose methods” and “dose-response curve methods.” In contrast, the mean doses found by the current approach may have in part depended on the dose ranges chosen for the original trials. Ultimate conclusions on dose equivalence of antipsychotics will need to be based on a review of various methods. PMID:25841041
Statistical analysis of radioimmunoassay. In comparison with bioassay (in Japanese)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakano, R.
1973-01-01
Using the data of RIA (radioimmunoassay), statistical procedures for dealing with two problems of the linearization of dose response curve and calculation of relative potency were described. There were three methods for linearization of dose response curve of RIA. In each method, the following parameters were shown on the horizontal and vertical axis: dose x, (B/T)/sup -1/; c/x + c, B/T (C: dose which makes B/T 50%); log x, logit B/T. Among them, the last method seems to be most practical. The statistical procedures for bioassay were employed for calculating the relative potency of unknown samples compared to the standardmore » samples from dose response curves of standand and unknown samples using regression coefficient. It is desirable that relative potency is calculated by plotting more than 5 points in the standard curve and plotting more than 2 points in unknow samples. For examining the statistical limit of precision of measuremert, LH activity of gonadotropin in urine was measured and relative potency, precision coefficient and the upper and lower limits of relative potency at 95% confidence limit were calculated. On the other hand, bioassay (by the ovarian ascorbic acid reduction method and anteriol lobe of prostate weighing method) was done in the same samples, and the precision was compared with that of RIA. In these examinations, the upper and lower limits of the relative potency at 95% confidence limit were near each other, while in bioassay, a considerable difference was observed between the upper and lower limits. The necessity of standardization and systematization of the statistical procedures for increasing the precision of RIA was pointed out. (JA)« less
The solar-flare infrared continuum - Observational techniques and upper limits
NASA Technical Reports Server (NTRS)
Hudson, H. S.
1975-01-01
Exploratory observations at 20 microns and 350 microns have determined detection thresholds for solar flares in these wavelengths. In the 20-micron range, solar atmospheric fluctuations (the 'temperature field') set the basic limits on flare detectability at about 5 K; at 350 microns, extinction in the earth's atmosphere provides the basic limitation of about 30 K. These thresholds are low enough for the successful detection of several infrared-emitting components of large flares. The upper limits obtained for subflares indicate that the thickness of the H-alpha flare region does not exceed approximately 10 km. This result confirms the conclusion of Suemoto and Hiei (1959) regarding the small effective thickness of the H-alpha-emitting regions in solar flares.
Severe neuropathy after high dose carboplatin in three patients receiving multidrug chemotherapy
Heinzlef, O.; Lotz, J.; Roullet, E.
1998-01-01
Three patients are described who developed a severe neuropathy after chemotherapy with high dose cis-diamine-(1,1-cyclobutane dicarboxylato) platinum (carboplatin). This toxic side effect, which is unusual at conventional doses, might become more frequent as increasing doses are administered to overcome drug resistance in cancer treatment, and might limit its use at very high doses before haematopoietic stem cell transplantation. PMID:9598687
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meinhold, C.B.
This report summarizes information required to estimate, at least qualitatively, the potential impacts of reducing occupational dose limits below those given in 10 CFR 20 (Revised). For this study, a questionnaire was developed and widely distributed to the radiation protection community. The resulting data together with data from existing surveys and sources were used to estimate the impact of three dose-limit options; 10 mSv yr{sup {minus}1} (1 rem yr{sup {minus}1}), 20 mSv yr{sup {minus}1} (2 rem yr{sup {minus}1}), and a combination of an annual limit of 50 mSv yr{sup {minus}1} (5 rem yr{sup {minus}1}) coupled with a cumulative limit, inmore » rem, equal to age in years. Due to the somewhat small number of responses and the lack of data in some specific areas, a working committee of radiation protection experts from a variety of licensees was employed to ensure the exposure data were representative. The following overall conclusions were reached: (1) although 10 mSv yr{sup {minus}1} is a reasonable limit for many licensees, such a limit could be extraordinarily difficult to achieve and potentially destructive to the continued operation of some licensees, such as nuclear power, fuel fabrication, and medicine; (2) twenty mSv yr{sup {minus}1} as a limit is possible for some of these groups, but for others it would prove difficult. (3) fifty mSv yr{sup {minus}1} and age in 10s of mSv appear reasonable for all licensees, both in terms of the lifetime risk of cancer and severe genetic effects to the most highly exposed workers, and the practicality of operation.« less
The Effect of Variant Dosages of Amphetamine Upon Endurance.
ERIC Educational Resources Information Center
Williams, Melvin H.; Thompson, John
The purpose of this study was to provide basic information concerning the acute effects of a small, moderate, and large dose of d-amphetamine sulfate upon muscular endurance; a secondary purpose involved the effect upon resting (R), and submaximal, and maximal (MAX) heart rate (HR). Twelve male university students underwent four separate trials of…
Transient hypothyroidism after withdrawal of thyroxin therapy
Distiller, L. A.; Joffe, B. I.
1975-01-01
Continued administration of large doses of thyroid may not produce hyperthyroidism in euthyroid individuals. Cessation of prolonged high-dosage thyroid replacement can cause transient clinical and biochemical hypothyroidism owing to pituitary suppression. A case is recorded in which both these phenomena are well demonstrated. This case highlights these basic endocrinological principles. PMID:1197170
DOE Office of Scientific and Technical Information (OSTI.GOV)
Talleur, Aimee C.; Navid, Fariba; Spunt, Sheri L.
Purpose: To determine the rate of local failure using focal conformal, limited margin radiation therapy (RT) and dose escalation for tumors ≥8 cm (greatest dimension at diagnosis) in children and young adults with Ewing sarcoma (EWS). Methods and Materials: Eligible patients with EWS were treated on a phase 2 institutional trial of focal conformal, limited margin RT using conformal or intensity modulated techniques. The treatment volume incorporated a 1-cm constrained margin around the gross tumor. Unresected tumors, <8 cm at diagnosis, received a standard dose of 55.8 Gy and tumors ≥8 cm, an escalated dose to 64.8 Gy. Patients with microscopic residual disease after resectionmore » received adjuvant RT to 50.4 Gy. Adjuvant brachytherapy was permitted in selected patients. Results: Forty-five patients were enrolled: 26 with localized and 19 with metastatic disease. Median (range) age, tumor size, and follow-up were 13.0 years (2.9-24.7 years), 9.0 cm (2.4-17.0 cm), and 54.5 months (1.9-122.2 months), respectively. All patients received systemic chemotherapy. The median (range) RT dose for all patients was 56.1 Gy (45-65.5 Gy). Seventeen patients received adjuvant, 16 standard-dose, and 12 escalated-dose RT. Failures included 1 local, 10 distant, and 1 local/distant. The estimated 10-year cumulative incidence of local failure was 4.4% ± 3.1%, with no statistical difference seen between RT treatment groups and no local failures in the escalated-dose RT treatment group. Conclusions: Treatment with focal conformal, limited margin RT, including dose escalation for larger tumors, provides favorable local tumor control in EWS.« less
Basic materials physics of transparent conducting oxides.
Edwards, P P; Porch, A; Jones, M O; Morgan, D V; Perks, R M
2004-10-07
Materials displaying the remarkable combination of high electrical conductivity and optical transparency already from the basis of many important technological applications, including flat panel displays, solar energy capture and other opto-electronic devices. Here we present the basic materials physics of these important materials centred on the nature of the doping process to generate n-type conductivity in transparent conducting oxides, the associated transition to the metallic (conducting) state and the detailed properties of the degenerate itinerant electron gas. The aim is to fully understand the origins of the basic performance limits of known materials and to set the scene for new or improved materials which will breach those limits for new-generation transparent conducting materials, either oxides, or beyond oxides.
Radiation dose to critical body organs for October 1989 proton event
NASA Technical Reports Server (NTRS)
Simonsen, Lisa C.; Atwell, William; Nealy, John E.; Cucinotta, Francis A.
1992-01-01
The Geostationary Operational Environmental Satellite (GOES-7) provides high-quality environmental data about the temporal development and energy characteristics of the protons emitted during a solar particle event. The GOES-7 time history of the hourly averaged integral proton flux for various particle kinetic energies are analyzed for the solar proton event occurring October 19-29, 1989. This event is similar to the August 1972 event that has been widely studied to estimate free-space and planetary radiation-protection requirements. By analyzing the time-history data, the dose rates, which can vary over many orders of magnitude in the early phases of the flare, can be estimated as well as the cumulative dose as a function of time. When basic transport results are coupled with detailed body organ thickness distributions calculated with the Computerized Anatomical Man and Computerized Anatomical Female models, the dose rates and cumulative doses to specific organs can be predicted. With these results, the risks of cancer incidence and mortality are estimated for astronauts in free space protected by various water shield thicknesses.
NASA Technical Reports Server (NTRS)
James, John T.; Lam, Chiu-wing; Scully, Robert R.
2013-01-01
Brief exposures of Apollo Astronauts to lunar dust occasionally elicited upper respiratory irritation; however, no limits were ever set for prolonged exposure ot lunar dust. Habitats for exploration, whether mobile of fixed must be designed to limit human exposure to lunar dust to safe levels. We have used a new technique we call Comparative Benchmark Dose Modeling to estimate safe exposure limits for lunar dust collected during the Apollo 14 mission.
Tonnonchiang, Siriporn; Sritongkul, Nopamon; Chaudakshetrin, Pachee; Tuntawiroon, Malulee
2016-02-01
Thyroid cancer patients treated with 1-131 are potential source of radiation exposure to relatives who are knowingly and willingly exposed to ionizing radiation as a result of providing comfort to patients undergoing I-131 therapy. This study aims to determine radiation dose received by relatives who care for non self-supporting 1-131 patients at Siriraj Hospital. Twenty caregivers of 20 patients underwent I-131 therapy for thyroid cancer with a standard protocol were given specific instructions with regard to radiation safety and provided with electronic digital dosimeter to continuously measure radiation dose received on daily basis, three days in the hospital. On the day patient is released, thyroid uptake estimates were performed to assess internal radiation dose received by caregivers. The 3-day accumulative doses to caregivers to patients receiving 150 mCi (n = 11) and 200 mCi (n = 9) of I-131 ranged from 37 to 333 uSv and 176 to 1,920 pSv respectively depending on the level of supports required. Thyroid uptake estimates in all caregivers were undetectable. Dosimeter indicated a maximum whole-body dose of1.92 mSv was more than the public dose limit of] mSv but within the dose constraint of 5 mSv for caregivers. Radiation dose to caregivers of a non self-supporting hospitalized patient undergoing 1-131 therapy were well below the limits recommended by the ICRP. The patients can be comforted with confidence that dose to caregivers will be less than the limit. This study provides guidance for medical practitioners to obtain practical radiation safety concerns associated with hospitalized patients receiving I-131 therapy especially when patient needs assistance.
Bautista, Francisco; Moreno, Lucas; Marshall, Lynley; Pearson, Andrew D J; Geoerger, Birgit; Paoletti, Xavier
2017-11-01
Dose-escalation trials aim to identify the maximum tolerated dose and, importantly, the recommended phase II dose (RP2D) and rely on the occurrence of dose-limiting toxicities (DLTs) during the first treatment cycle. Molecularly targeted agents (MTAs) often follow continuous and prolonged administrations, displaying a distinct toxicity profile compared to conventional chemotherapeutics, and classical DLT criteria might not be appropriate to evaluate MTAs' toxicity. We investigated this issue in children. The Innovative Therapies for Children with Cancer Consortium (ITCC) phase I trials of novel anticancer agents between 2004 and 2015 were analysed. Data from investigational product, trial design, items defining DLT/RP2D were extracted. A survey on dose-escalation process, DLTs and RP2D definition was conducted among the ITCC clinical trials committee members. Thirteen phase I trials with 15 dose-escalation cohorts were analysed. They explored 11 MTAs and 2 novel cytotoxics; 12 evaluated DLT during cycle 1. Definition of DLT was heterogeneous: Grade III-IV haematologic toxicities that were transient or asymptomatic and grade III-IV non-haematological toxicities manageable with adequate supportive care were often excluded, whereas some included dose intensity or grade II toxicities into DLT. None of the studies considered delayed toxicity into the RP2D definition. DLTs should be homogeneously defined across trials, limiting the number of exceptions due to specific toxicities. Dose escalation should still be based on safety data from cycle 1, but delayed and overall toxicities, pharmacokinetic parameters and pharmacodynamic data should be considered to refine the final RP2D. The evaluation of long-term toxicity in the developing child cannot be adequately addressed in early trials. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Esor, J.; Sudchai, W.; Monthonwattana, S.; Pungkun, V.; Intang, A.
2017-06-01
Based on a new occupational dose limit recommended by ICRP (2011), the annual dose limit for the lens of the eye for workers should be reduced from 150 mSv/y to 20 mSv/y averaged over 5 consecutive years in which no single year exceeding 50 mSv. This new dose limit directly affects radiologists and cardiologists whose work involves high radiation exposure over 20 mSv/y. Eye lens dosimetry (Hp(3)) has become increasingly important and should be evaluated directly based on dosimeters that are worn closely to the eye. Normally, Hp(3) dose algorithm was carried out by the combination of Hp(0.07) and Hp(10) values while dosimeters were calibrated on slab PMMA phantom. Recently, there were three reports from European Union that have shown the conversion coefficients from air kerma to Hp(3). These conversion coefficients carried out by ORAMED, PTB and CEA Saclay projects were performed by using a new cylindrical head phantom. In this study, various delivered doses were calculated using those three conversion coefficients while nanoDot, small OSL dosimeters, were used for Hp(3) measurement. These calibrations were performed with a standard X-ray generator at Secondary Standard Dosimetry Laboratory (SSDL). Delivered doses (Hp(3)) using those three conversion coefficients were compared with Hp(3) from nanoDot measurements. The results showed that percentage differences between delivered doses evaluated from the conversion coefficient of each project and Hp(3) doses evaluated from the nanoDots were found to be not exceeding -11.48 %, -8.85 % and -8.85 % for ORAMED, PTB and CEA Saclay project, respectively.
Energy spectrum control for modulated proton beams.
Hsi, Wen C; Moyers, Michael F; Nichiporov, Dmitri; Anferov, Vladimir; Wolanski, Mark; Allgower, Chris E; Farr, Jonathan B; Mascia, Anthony E; Schreuder, Andries N
2009-06-01
In proton therapy delivered with range modulated beams, the energy spectrum of protons entering the delivery nozzle can affect the dose uniformity within the target region and the dose gradient around its periphery. For a cyclotron with a fixed extraction energy, a rangeshifter is used to change the energy but this produces increasing energy spreads for decreasing energies. This study investigated the magnitude of the effects of different energy spreads on dose uniformity and distal edge dose gradient and determined the limits for controlling the incident spectrum. A multilayer Faraday cup (MLFC) was calibrated against depth dose curves measured in water for nonmodulated beams with various incident spectra. Depth dose curves were measured in a water phantom and in a multilayer ionization chamber detector for modulated beams using different incident energy spreads. Some nozzle entrance energy spectra can produce unacceptable dose nonuniformities of up to +/-21% over the modulated region. For modulated beams and small beam ranges, the width of the distal penumbra can vary by a factor of 2.5. When the energy spread was controlled within the defined limits, the dose nonuniformity was less than +/-3%. To facilitate understanding of the results, the data were compared to the measured and Monte Carlo calculated data from a variable extraction energy synchrotron which has a narrow spectrum for all energies. Dose uniformity is only maintained within prescription limits when the energy spread is controlled. At low energies, a large spread can be beneficial for extending the energy range at which a single range modulator device can be used. An MLFC can be used as part of a feedback to provide specified energy spreads for different energies.
Phase I Study of Vandetanib With Radiotherapy and Temozolomide for Newly Diagnosed Glioblastoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drappatz, Jan; Norden, Andrew D.; Division of Cancer Neurology, Department of Neurology, Brigham and Women's Hospital, Boston, MA
Purpose: Increasing evidence has suggested that angiogenesis inhibition might potentiate the effects of radiotherapy and chemotherapy in patients with glioblastoma (GBM). In addition, epidermal growth factor receptor inhibition might be of therapeutic benefit, because the epidermal growth factor receptor is upregulated in GBM and contributes to radiation resistance. We conducted a Phase I study of vandetanib, an inhibitor of vascular endothelial growth factor receptor 2 and epidermal growth factor receptor, in patients with newly diagnosed GBM combined with RT and temozolomide (TMZ). Methods and Materials: A total of 13 GBM patients were treated with vandetanib, radiotherapy, and concurrent and adjuvantmore » TMZ, using a standard '3 + 3' dose escalation. The maximal tolerated dose was defined as the dose with <1 of 6 dose-limiting toxicities during the first 12 weeks of therapy. The eligible patients were adults with newly diagnosed GBM, Karnofsky performance status of {>=}60, normal organ function, who were not taking enzyme-inducing antiepileptic drugs. Results: Of the 13 patients, 6 were treated with vandetanib at a dose of 200mg daily. Of the 6 patients, 3 developed dose-limiting toxicities within the first 12 weeks, including gastrointestinal hemorrhage and thrombocytopenia in 1 patient, neutropenia in 1 patient, and diverticulitis with gastrointestinal perforation in 1 patient. The other 7 patients were treated with 100 mg daily, with no dose-limiting toxicities observed, establishing this dose as the maximal tolerated dose combined with TMZ and RT. Conclusion: Vandetanib can be safely combined with RT and TMZ in GBM patients. A Phase II study in which patients are randomized to vandetanib 100 mg daily with RT and TMZ or RT and TMZ alone is underway.« less
1981-09-01
corresponds to the same square footage that consumed the electrical energy. 3. The basic assumptions of multiple linear regres- sion, as enumerated in...7. Data related to the sample of bases is assumed to be representative of bases in the population. Limitations Basic limitations on this research were... Ratemaking --Overview. Rand Report R-5894, Santa Monica CA, May 1977. Chatterjee, Samprit, and Bertram Price. Regression Analysis by Example. New York: John
Emergency EPR and OSL dosimetry with table vitamins and minerals.
Sholom, S; McKeever, S W S
2016-12-01
Several table vitamins, minerals and L-lysine amino acid have been preliminarily tested as potential emergency dosemeters using electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) techniques. Radiation-induced EPR signals were detected in samples of vitamin B2 and L-lysine while samples of multivitamins of different brands as well as mineral Mg demonstrated prominent OSL signals after exposure to ionizing radiation doses. Basic dosimetric properties of the radiation-sensitive substances were studied, namely dose response, fading of the EPR or OSL signals and values of minimum measurable doses (MMDs). For EPR-sensitive samples, the EPR signal is converted into units of dose using a linear dose response and correcting for fading using the measured fading dependence. For OSL-sensitive materials, a multi-aliquot, enhanced-temperature protocol was developed to avoid the problem of sample sensitization and to minimize the influence of signal fading. The sample dose in this case is also evaluated using the dose response and fading curves. MMDs of the EPR-sensitive samples were below 2 Gy while those of the OSL-sensitive materials were below 500 mGy as long as the samples are analyzed within 1 week after exposure. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Dose-response approaches for nuclear receptor-mediated ...
A public workshop, organized by a Steering Committee of scientists from government, industry, universities, and research organizations, was held at the National Institute of Environmental Health Sciences (NIEHS) in September, 2010. The workshop explored the dose-response implications of toxicant modes of action (MOA) mediated by nuclear receptors. The dominant paradigm in human health risk assessment has been linear extrapolation without a threshold for cancer, and estimation of sub-threshold doses for non-cancer and (in appropriate cases) cancer endpoints. However, recent publications question the application of dose-response modeling approaches with a threshold. The growing body of molecular toxicology information and computational toxicology tools has allowed for exploration of the presence or absence of subthreshold doses for a number of receptor-mediated MOPs. The workshop explored the development of dose-response approaches for nuclear receptor-mediated liver cancer, within a MOA Human Relevance framework (HRF). Case studies addressed activation of the AHR; the CAR/PXR, and the PPARa. This paper describes the workshop process, key issues discussed, and conclusions. The value of an interactive workshop approach to apply current MOA/HRF frameworks was demonstrated. The results may help direct research on the MOA and dose-response of receptor-based toxicity, since there are commonalities for many receptors in the basic pathways involved for late steps in the
Sterile Basics of Compounding: Relationship Between Syringe Size and Dosing Accuracy.
Kosinski, Tracy M; Brown, Michael C; Zavala, Pedro J
2018-01-01
The purpose of this study was to investigate the accuracy and reproducibility of a 2-mL volume injection using a 3-mL and 10-mL syringe with pharmacy student compounders. An exercise was designed to assess each student's accuracy in compounding a sterile preparation with the correct 4-mg strength using a 3-mL and 10-mL syringe. The average ondansetron dose when compounded with the 3-mL syringe was 4.03 mg (standard deviation ± 0.45 mg), which was not statistically significantly different than the intended 4-mg desired dose (P=0.497). The average ondansetron dose when compounded with the 10-mL syringe was 4.18 mg (standard deviation + 0.68 mg), which was statistically significantly different than the intended 4-mg desired dose (P=0.002). Additionally, there also was a statistically significant difference in the average ondansetron dose compounded using a 3-mL syringe (4.03 mg) and a 10-mL syringe (4.18 mg) (P=0.027). The accuracy and reproducibility of the 2-mL desired dose volume decreased as the compounding syringe size increased from 3 mL to 10 mL. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Crespo, M; Mir, M; Marin, M; Hurtado, S; Estadella, C; Gurí, X; Rap, O; Moral, R; Puig, J M; Lloveras, J
2009-01-01
Advagraf is a new modified-release once-daily formulation of tacrolimus with a similar efficacy and safety profile to twice-daily tacrolimus (Prograf) according to clinical trials. Few data are published about its use in clinical practice, outside of sponsored clinical trials. We compared efficacy and basic pharmacokinetics of once-daily and twice-daily tacrolimus in de novo renal transplantation. The Advagraf group included 26 de novo renal cases who had received initial immunosuppression with once-daily tacrolimus (0.2 mg/kg from day 1 posttransplantation) combined with mycophenolic acid, steroids, and anti-CD25 monoclonal antibodies (2 doses). We compared them with a Prograf group of 26 transplants performed immediately before, who received equivalent immunosuppression with twice-daily tacrolimus (0.2 mg/kg from day 1). We did not observe significant differences between groups in demographics, efficacy, and basic pharmacokinetics, namely, tacrolimus trough levels at 7, 15, 30, 60, or 90 days. We found that recipients on Advagraf needed significantly higher tacrolimus doses per kg up to 6 months post-transplantation than those on Prograf: 0.16 vs 0.11; 0.14 vs 0.08; and 0.12 vs 0.08 mg/kg at 1, 3, and 6 months. No patient suffered severe liver dysfunction. There were no differences between groups in the administration of drugs interacting with CYP3A4 or prokinetics, which could alter tacrolimus pharmacokinetics. Among de novo renal cases, the new once-daily formulation of tacrolimus offered a similar short-term efficacy profile as the twice-daily tacrolimus. But it was necessary to use up to a 50% higher dose of Advagraf than Prograf to achieve similar trough levels during the first 6 months.
A 90-Day Feeding Study in Rats to Assess the Safety of Genetically Engineered Pork.
Xiao, Gao-Jun; Jiang, Sheng-Wang; Qian, Li-Li; Cai, Chun-Bo; Wang, Qing-Qing; Ma, De-Zun; Li, Biao; Xie, Shan-Shan; Cui, Wen-Tao; Li, Kui
2016-01-01
Our laboratory recently produced genetically engineered (GE) Meishan pigs containing a ZFN-edited myostatin loss-of-function mutant. These GE pigs develop and grow as normal as wild type pigs but produce pork with greater lean yield and lower fat mass. To assess any potential subchronic toxicity risks of this GE pork, a 90-day feeding study was conducted in Sprague-Dawley rats. Rats were randomly divided into five groups, and fed for 90 days with basic diet and basic diets formulated with low dose and high dose pork prepared from wild type pigs and GE pigs, respectively. Animal behaviors and clinical signs were monitored twice daily, and body weight and food consumption were measured and recorded weekly. At days 45 and 90, blood tests (lipid panel, electrolytes, parameters related to liver and kidney functions, and complete blood counts) were performed. Additionally, gross pathology and histopathological analyses were performed for major organs in each group. Data analysis shows that there were no significant differences in growth rate, food consumption, and blood test parameters between rat groups fed with GE pork and wild type pork. Although differences in some liver function parameters (such as aspartate aminotransferase, total proteins, albumin, and alkaline phosphatase) and white blood cell counts (such as lymphocyte percentage and monocyte percentage) were observed between rats fed with high dose GE pork and basic diet, all test results in rats fed with GE pork are in the normal range. Additionally, there are no apparent lesions noted in all organs isolated from rats in all five feeding groups on days 45 and 90. Overall, our results clearly indicate that food consumption of GE pork produced by ZFN-edited myostatin loss-of-function mutant pigs did not have any long-term adverse effects on the health status in rats.
A 90-Day Feeding Study in Rats to Assess the Safety of Genetically Engineered Pork
Xiao, Gao-jun; Jiang, Sheng-Wang; Qian, Li-Li; Cai, Chun-Bo; Wang, Qing-qing; Ma, De-Zun; Li, Biao; Xie, Shan-shan; Cui, Wen-Tao; Li, Kui
2016-01-01
Our laboratory recently produced genetically engineered (GE) Meishan pigs containing a ZFN-edited myostatin loss-of-function mutant. These GE pigs develop and grow as normal as wild type pigs but produce pork with greater lean yield and lower fat mass. To assess any potential subchronic toxicity risks of this GE pork, a 90-day feeding study was conducted in Sprague-Dawley rats. Rats were randomly divided into five groups, and fed for 90 days with basic diet and basic diets formulated with low dose and high dose pork prepared from wild type pigs and GE pigs, respectively. Animal behaviors and clinical signs were monitored twice daily, and body weight and food consumption were measured and recorded weekly. At days 45 and 90, blood tests (lipid panel, electrolytes, parameters related to liver and kidney functions, and complete blood counts) were performed. Additionally, gross pathology and histopathological analyses were performed for major organs in each group. Data analysis shows that there were no significant differences in growth rate, food consumption, and blood test parameters between rat groups fed with GE pork and wild type pork. Although differences in some liver function parameters (such as aspartate aminotransferase, total proteins, albumin, and alkaline phosphatase) and white blood cell counts (such as lymphocyte percentage and monocyte percentage) were observed between rats fed with high dose GE pork and basic diet, all test results in rats fed with GE pork are in the normal range. Additionally, there are no apparent lesions noted in all organs isolated from rats in all five feeding groups on days 45 and 90. Overall, our results clearly indicate that food consumption of GE pork produced by ZFN-edited myostatin loss-of-function mutant pigs did not have any long-term adverse effects on the health status in rats. PMID:27812153
Opioid needs of patients with advanced cancer and the morphine dose-limiting law in Egypt.
Alsirafy, Samy A; El-Mesidi, Salah M; El-Sherief, Wesam A; Galal, Khaled M; Abou-Elela, Enas N; Aklan, Nahla A
2011-01-01
Morphine is the drug of choice for moderate to severe cancer pain management. The Egyptian Narcotics Control Law limits the amount of morphine prescribed in a single prescription to a maximum of 420 mg for tablets and 60 mg for ampoules. The usual practice in Egypt is to provide that limited amount of morphine on a weekly basis. The aim of this study is to estimate the extent to which Egyptian patients may be undertreated because of this law. We reviewed the medical records of advanced cancer patients referred to the first palliative care unit in Egypt over a seven-month period. Cancer pain was managed following the WHO guidelines. After modifying the internal institutional policy, patients received adequate amounts of the available opioids without any violations of the law. From 117 eligible advanced cancer patients, 58 (50%) patients required strong opioids, 32 (27%) required weak opioids, and 27 (23%) required no regular opioids. The mean last prescribed opioid dose for those who required strong opioids was 194 mg of oral morphine equivalent/24 h (± 180). For this group of patients, a single weekly prescription would supply enough oral morphine for only 26% of them. In the case of parenteral morphine, none of these patients would receive an adequate supply. In view of the current morphine dose-limiting law and practices in Egypt, the majority of patients suffering severe cancer pain would not have access to adequate morphine doses. That dose-limiting law and other restrictive regulations represent an obstacle to cancer pain control in Egypt and should be revised urgently.
Guiu-Souto, Jacobo; Sánchez-García, Manuel; Vázquez-Vázquez, Rubén; Otero, Carlos; Luna, Victor; Mosquera, Javier; Busto, Ramón Lobato; Aguiar, Pablo; Ruibal, Álvaro; Pardo-Montero, Juan; Pombar-Cameán, Miguel
2016-06-01
The last recommendations of the International Commission on Radiological Protection for eye lens dose suggest an important reduction on the radiation limits associated with early and late tissue reactions. The aim of this work is to quantify and optimize the eye lens dose associated to nurse staff during positron emission tomography (PET) procedures. PET is one of the most important diagnostic methods of oncological and neurological cancer disease involving an important number of workers exposed to the high energy isotope F-18. We characterize the relevant stages as preparation and administration of monodose syringes in terms of occupational dose. A direct reading silicon dosimeter was used to measure the lens dose to staff. The highest dose of radiation was observed during preparation of the fluorodesoxyglucose (FDG) syringes. By optimizing a suitable vials' distribution of FDG we find an important reduction in occupational doses. Extrapolation of our data to other clinical scenarios indicates that, depending on the work load and/or syringes activity, safety limits of the dose might be exceeded.
Radionuclides in bats using a contaminated pond on the Nevada National Security Site, USA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warren, Ronald W.; Hall, Derek B.; Greger, Paul D.
In this study, perched groundwater percolating through radionuclide contamination in the E Tunnel Complex on the Nevada National Security Site, formerly the Nevada Test Site, emerges and is stored in a series of ponds making it available to wildlife, including bats. Since many bat species using the ponds are considered sensitive or protected/regulated and little information is available on dose to bats from radioactive water sources, bats were sampled to determine if the dose they were receiving exceeded the United States Department of Energy dose limit of 1.0E-3 Gy/day. Radionuclide concentrations in water, sediment, and flying insects were also measuredmore » as input parameters to the dose rate model and to examine trophic level relationships. The RESRAD-Biota model was used to calculate dose rates to bats using different screening levels. Efficacy of RESRAD-Biota and suggested improvements are discussed. Finally, dose to bats foraging and drinking at these ponds is well below the dose limit set to protect terrestrial biota populations.« less
Radionuclides in bats using a contaminated pond on the Nevada National Security Site, USA
Warren, Ronald W.; Hall, Derek B.; Greger, Paul D.
2014-01-03
In this study, perched groundwater percolating through radionuclide contamination in the E Tunnel Complex on the Nevada National Security Site, formerly the Nevada Test Site, emerges and is stored in a series of ponds making it available to wildlife, including bats. Since many bat species using the ponds are considered sensitive or protected/regulated and little information is available on dose to bats from radioactive water sources, bats were sampled to determine if the dose they were receiving exceeded the United States Department of Energy dose limit of 1.0E-3 Gy/day. Radionuclide concentrations in water, sediment, and flying insects were also measuredmore » as input parameters to the dose rate model and to examine trophic level relationships. The RESRAD-Biota model was used to calculate dose rates to bats using different screening levels. Efficacy of RESRAD-Biota and suggested improvements are discussed. Finally, dose to bats foraging and drinking at these ponds is well below the dose limit set to protect terrestrial biota populations.« less
DOSE-DEPENDENT TRANSITIONS IN MECHANISMS OF TOXICITY: CASE STUDIES
Experience with dose response and mechanisms of toxicity has shown that multiple mechanisms may exist for a single agent along the continuum of the full dose-response curve. It is highly likely that critical, limiting steps in any given mechanistic pathway may become overwhelmed ...
Psychopharmacology of theobromine in healthy volunteers.
Baggott, Matthew J; Childs, Emma; Hart, Amy B; de Bruin, Eveline; Palmer, Abraham A; Wilkinson, Joy E; de Wit, Harriet
2013-07-01
Theobromine, a methylxanthine related to caffeine and present in high levels in cocoa, may contribute to the appeal of chocolate. However, current evidence for this is limited. We conducted a within-subjects placebo-controlled study of a wide range of oral theobromine doses (250, 500, and 1,000 mg) using an active control dose of caffeine (200 mg) in 80 healthy participants. Caffeine had the expected effects on mood including feelings of alertness and cardiovascular parameters. Theobromine responses differed according to dose; it showed limited subjective effects at 250 mg and negative mood effects at higher doses. It also dose-dependently increased heart rate. In secondary analyses, we also examined individual differences in the drug's effects in relation to genes related to their target receptors, but few associations were detected. This study represents the highest dose of theobromine studied in humans. We conclude that theobromine at normal intake ranges may contribute to the positive effects of chocolate, but at higher intakes, effects become negative.
Psychopharmacology of theobromine in healthy volunteers
Baggott, Matthew J.; Childs, Emma; Hart, Amy B.; de Bruin, Eveline; Palmer, Abraham A.; Wilkinson, Joy E.; de Wit, Harriet
2013-01-01
Background Theobromine, a methylxanthine related to caffeine and present in high levels in cocoa, may contribute to the appeal of chocolate. However, currently evidence for this is limited. Objectives We conducted a within-subjects placebo-controlled study of a wide range of oral theobromine doses (250, 500, and 1000 mg) using an active control dose of caffeine (200 mg) in 80 healthy participants. Results Caffeine had the expected effects on mood including feelings of alertness, and cardiovascular parameters. Theobromine responses differed according to dose: it showed limited subjective effects at 250 mg and negative mood effects at higher doses. It also dose-dependently increased heart rate. In secondary analyses we also examined individual differences in the drugs' effects in relation to genes related to their target receptors, but few associations were detected. Conclusions This study represents the highest dose of theobromine studied in humans. We conclude that theobromine at normal intake ranges may contribute to the positive effects of chocolate, but at higher intakes effects become negative. PMID:23420115
21 CFR 520.2380c - Thiabendazole bolus.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Limitations. As a single oral dose; may repeat once in 2 to 3 weeks; do not treat animals within 3 days of...) Chemical name. 2-(4-Thiazolyl) benzimidazole. (b) Specifications. Conforms to N.F. XII. (c) Sponsor. See No...) Limitations. As a single oral dose; as a drench or bolus; may repeat once in 2 to 3 weeks; do not treat...
21 CFR 520.2380c - Thiabendazole bolus.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) Limitations. As a single oral dose; may repeat once in 2 to 3 weeks; do not treat animals within 3 days of...) Chemical name. 2-(4-Thiazolyl) benzimidazole. (b) Specifications. Conforms to N.F. XII. (c) Sponsor. See No...) Limitations. As a single oral dose; as a drench or bolus; may repeat once in 2 to 3 weeks; do not treat...
10 CFR 72.106 - Controlled area of an ISFSI or MRS.
Code of Federal Regulations, 2012 CFR
2012-01-01
... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...
10 CFR 72.106 - Controlled area of an ISFSI or MRS.
Code of Federal Regulations, 2014 CFR
2014-01-01
... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...
10 CFR 72.106 - Controlled area of an ISFSI or MRS.
Code of Federal Regulations, 2011 CFR
2011-01-01
... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...
10 CFR 72.106 - Controlled area of an ISFSI or MRS.
Code of Federal Regulations, 2013 CFR
2013-01-01
... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...
10 CFR 72.106 - Controlled area of an ISFSI or MRS.
Code of Federal Regulations, 2010 CFR
2010-01-01
... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...
Orthodontics for the dog. Bite evaluation, basic concepts, and equipment.
Ross, D L
1986-09-01
Evaluation of canine occlusion (an occlusal evaluation table is included), growth patterns of the head, basic concepts of orthodontics such as how teeth move, length of treatment, and limits to movements, and equipment and materials are considered in this article.
Role of particle radiotherapy in the management of head and neck cancer.
Laramore, George E
2009-05-01
Modern imaging techniques and powerful computers allow a radiation oncologist to design treatments delivering higher doses of radiation than previously possible. Dose distributions imposed by the physics of 'standard' photon and electron beams limit further dose escalation. Hadron radiotherapy offers advantages in either dose distribution and/or improved radiobiology that may significantly improve the treatment of certain head and neck malignancies. Clinical studies support the effectiveness of fast-neutron radiotherapy in the treatment of major and minor salivary gland tumors. Data show highly favorable outcomes with proton radiotherapy for skull-base malignancies and tumors near highly critical normal tissues compared with that expected with standard radiotherapy. Heavy-ion radiotherapy clinical studies are mainly being conducted with fully stripped carbon ions, and limited data seem to indicate a possible improvement over proton radiotherapy for the same subset of radioresistant tumors where neutrons show a benefit over photons. Fast-neutron radiotherapy has different radiobiological properties compared with standard radiotherapy but similar depth dose distributions. Its role in the treatment of head and neck cancer is currently limited to salivary gland malignancies and certain radioresistant tumors such as sarcomas. Protons have the same radiobiological properties as standard radiotherapy beams but more optimal depth dose distributions, making it particularly advantageous when treating tumors adjacent to highly critical structures. Heavy ions combine the radiobiological properties of fast neutrons with the physical dose distributions of protons, and preliminary data indicate their utility for radioresistant tumors adjacent to highly critical structures.
Assessment of national dosimetry quality audits results for teletherapy machines from 1989 to 2015.
Muhammad, Wazir; Ullah, Asad; Mahmood, Khalid; Matiullah
2016-01-01
The purpose of this study was to ensure accuracy in radiation dose delivery, external dosimetry quality audit has an equal importance with routine dosimetry performed at clinics. To do so, dosimetry quality audit was organized by the Secondary Standard Dosimetry Laboratory (SSDL) of Pakistan Institute of Nuclear Science and Technology (PINSTECH) at the national level to investigate and minimize uncertainties involved in the measurement of absorbed dose, and to improve the accuracy of dose measurement at different radiotherapy hospitals. A total of 181 dosimetry quality audits (i.e., 102 of Co-60 and 79 of linear accelerators) for teletherapy units installed at 22 different sites were performed from 1989 to 2015. The percent deviation between users’ calculated/stated dose and evaluated dose (in the result of on-site dosimetry visits) were calculated and the results were analyzed with respect to the limits of ± 2.5% (ICRU "optimal model") ± 3.0% (IAEA on-site dosimetry visits limit) and ± 5.0% (ICRU minimal or "lowest acceptable" model). The results showed that out of 181 total on-site dosimetry visits, 20.44%, 16.02%, and 4.42% were out of acceptable limits of ± 2.5% ± 3.0%, and ± 5.0%, respectively. The importance of a proper ongoing quality assurance program, recommendations of the followed protocols, and properly calibrated thermometers, pressure gauges, and humidity meters at radiotherapy hospitals are essential in maintaining consistency and uniformity of absorbed dose measurements for precision in dose delivery.
Robust EM Continual Reassessment Method in Oncology Dose Finding
Yuan, Ying; Yin, Guosheng
2012-01-01
The continual reassessment method (CRM) is a commonly used dose-finding design for phase I clinical trials. Practical applications of this method have been restricted by two limitations: (1) the requirement that the toxicity outcome needs to be observed shortly after the initiation of the treatment; and (2) the potential sensitivity to the prespecified toxicity probability at each dose. To overcome these limitations, we naturally treat the unobserved toxicity outcomes as missing data, and use the expectation-maximization (EM) algorithm to estimate the dose toxicity probabilities based on the incomplete data to direct dose assignment. To enhance the robustness of the design, we propose prespecifying multiple sets of toxicity probabilities, each set corresponding to an individual CRM model. We carry out these multiple CRMs in parallel, across which model selection and model averaging procedures are used to make more robust inference. We evaluate the operating characteristics of the proposed robust EM-CRM designs through simulation studies and show that the proposed methods satisfactorily resolve both limitations of the CRM. Besides improving the MTD selection percentage, the new designs dramatically shorten the duration of the trial, and are robust to the prespecification of the toxicity probabilities. PMID:22375092
Status of eye lens radiation dose monitoring in European hospitals.
Carinou, Eleftheria; Ginjaume, Merce; O'Connor, Una; Kopec, Renata; Sans Merce, Marta
2014-12-01
A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.
Rehani, Madan M; Vano, Eliseo; Ciraj-Bjelac, Olivera; Kleiman, Norman J
2011-09-01
When this paper was about to go to press, the International Commission on Radiological Protection released a statement recommending a change in the threshold dose for the eye lens and dose limits for eye for occupationally exposed persons. It is clear that the earlier published threshold for radiation cataract is no longer valid. Epidemiological studies among Chernobyl clean-up workers, A bomb survivors, astronauts, residents of contaminated buildings, radiological technicians and recent surveys of staff in interventional rooms indicate that there is an increased incidence of lens opacities at doses below 1 Gy. Nevertheless, eye lens dosimetry is at a primitive stage and needs to be developed further. Despite uncertainties concerning dose threshold and dosimetry, it is possible to significantly reduce the risk of radiation cataract through the use of appropriate eye protection. By increasing awareness among those at risk and better adoption and increased usage of protective measures, radiation cataract can become preventable despite lowering of dose limits.
Marshall, John; Shapiro, Geoffrey I; Uttenreuther-Fischer, Martina; Ould-Kaci, Mahmoud; Stopfer, Peter; Gordon, Michael S
2013-02-01
To determine the maximum tolerated dose (MTD), safety and anti-tumor activity of afatinib combined with docetaxel in advanced cancer. The MTD was determined from dose-limiting toxicities in the first cycle. Thirty-one patients received 10, 20 and 30 mg oral afatinib, plus 60 and 75 mg/m(2) intravenous docetaxel (six cohorts; 3-week cycles). The MTD of afatinib was 20 mg/day (days 2-21) with 75 mg/m(2) docetaxel (day 1). Dose-limiting toxicities were grade 3/4 diarrhea (n = 3) and febrile neutropenia (n = 6). Most frequently occurring adverse events were diarrhea, neutropenia and rash. Disease stabilization occurred in 14 patients. Afatinib 20 mg/day plus docetaxel was suboptimal and the study could not yield Phase II dose recommendations. The combination resulted in a manageable safety profile.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruedig, Elizabeth; Whicker, Jeffrey Jay
In 2017, soil sampling for radiological materials was conducted within Tract A-18-2 specifically for land conveyance decisions. Measurements of radionuclides in soil samples were evaluated against a recreational use scenario, and all measurements were below screening action levels for each radionuclide. The total estimated dose was less than 1 mrem/y (< 10 μSv/y) for a hypothetical recreational user (compared to a dose limit of 25 mrem/y (250 μSv/y)). Dose estimates were based on the 95% upper confidence limits for radionuclide concentrations within the Tract. Additionally, dose estimates less than 3 mrem/y are considered to be As Low As Reasonably Achievable,more » so no follow-up analysis was conducted. Release of this property is consistent with the requirements of DOE Order 458.1 and Policy 412.« less
Dosimetry in nuclear medicine therapy: radiobiology application and results.
Strigari, L; Benassi, M; Chiesa, C; Cremonesi, M; Bodei, L; D'Andrea, M
2011-04-01
The linear quadratic model (LQM) has largely been used to assess the radiobiological damage to tissue by external beam fractionated radiotherapy and more recently has been extended to encompass a general continuous time varying dose rate protocol such as targeted radionuclide therapy (TRT). In this review, we provide the basic aspects of radiobiology, from a theoretical point of view, starting from the "four Rs" of radiobiology and introducing the biologically effective doses, which may be used to quantify the impact of a treatment on both tumors and normal tissues. We also present the main parameters required in the LQM, and illustrate the main models of tumor control probability and normal tissue complication probability and summarize the main dose-effect responses, reported in literature, which demonstrate the tentative link between targeted radiotherapy doses and those used in conventional radiotherapy. A better understanding of the radiobiology and mechanisms of action of TRT could contribute to describe the clinical data and guide the development of future compounds and the designing of prospective clinical trials.
What happens when spins meet for ionizing radiation dosimetry?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pavoni, Juliana F.; Baffa, Oswaldo, E-mail: baffa@usp.br; Neves-Junior, Wellington F. P.
2016-07-07
Electron spin resonance (ESR) and magnetic resonance imaging (MRI) can be used to measure radiation dose deposited in different milieu through its effects. Radiation can break chemical bonds and if they produce stable free radicals, ESR can measure their concentration through their spins and a dose can be inferred. Ionizing radiation can also promote polymerization and in this case proton relaxation times can be measured and an image weighed by T2 can be produced giving spatial information about dose. A review of the basics of these applications is presented concluding with an end-to-end test using a composite Gel-Alanine phantom tomore » validate 3-dimensionally dose distribution delivered in a simulation of Volume Modulated Arch Therapy on the simultaneous treatment of multiple brain metastases. The results obtained with the gel and alanine dosimeters are consistent with the expected by the treatment planning system, showing the potential of this multidosimetric approach and validating dosimetrically the multiple brain metastases treatment using VMAT.« less
What happens when spins meet for ionizing radiation dosimetry?
NASA Astrophysics Data System (ADS)
Pavoni, Juliana F.; Neves-Junior, Wellington F. P.; Baffa, Oswaldo
2016-07-01
Electron spin resonance (ESR) and magnetic resonance imaging (MRI) can be used to measure radiation dose deposited in different milieu through its effects. Radiation can break chemical bonds and if they produce stable free radicals, ESR can measure their concentration through their spins and a dose can be inferred. Ionizing radiation can also promote polymerization and in this case proton relaxation times can be measured and an image weighed by T2 can be produced giving spatial information about dose. A review of the basics of these applications is presented concluding with an end-to-end test using a composite Gel-Alanine phantom to validate 3-dimensionally dose distribution delivered in a simulation of Volume Modulated Arch Therapy on the simultaneous treatment of multiple brain metastases. The results obtained with the gel and alanine dosimeters are consistent with the expected by the treatment planning system, showing the potential of this multidosimetric approach and validating dosimetrically the multiple brain metastases treatment using VMAT.
NASA Astrophysics Data System (ADS)
Buranurak, S.; Andersen, C. E.
2017-06-01
Radiotherapy technologies have improved for several decades aiming to effectively destroy cancerous tissues without overdosing surrounding healthy tissues. In order to fulfil this requirement, accurate and precise dosimetry systems play an important role. Throughout the years, ionization chambers have been used as a standard detector for basic linear accelerator calibrations and reference dosimetry in hospitals. However, they are not ideal for all treatment modalities: and limitations and difficulties have been reported in case of (i) small treatment fields, (ii) strong magnetic field used in the new hybrid MRI LINAC/cobalt systems, and (iii) in vivo measurements due to safety-issues related to the high operating voltage. Fiber optically coupled luminescence detectors provide a promising supplement to ionization chambers by offering the capability of real-time in vivo dose monitoring with high time resolution. In particular, the all-optical nature of these detectors is an advantage for in vivo measurements due to the absence of high voltage supply or electrical wire that could cause harm to the patient or disturb the treatment. Basically, fiber-coupled luminescence detector systems function by radiation-induced generation of radioluminescence from a sub-mm size organic/inorganic phosphor. A thin optical fiber cable is used for guiding the radioluminescence to a photomultiplier tube or similar sensitive light detection systems. The measured light intensity is proportional to dose rate. Throughout the years, developments and research of the fiber detector systems have undergone in several groups worldwide. In this article, the in-house developed fiber detector systems based on two luminescence phosphors of (i) BCF-60 polystyrene-based organic plastic scintillator and (ii) carbon-doped aluminum oxide crystal (Al2O3:C) are reviewed with comparison to the same material-based systems reported in the literature. The potential use of these detectors for reference-class dosimetry in radiotherapy will be discussed with a particular emphasis on uses in small and large MV photon fields.
General 4-week toxicity study with EMS in the rat.
Pfister, Thomas; Eichinger-Chapelon, Anne
2009-11-12
In this subacute toxicity study, ethyl methanesulfonate (EMS) was administered daily by oral gavage to SPF-bred Wistar rats of both sexes at dose levels of 20, 60 and 180/120 mg/kg body weight (bw)/day for a period of 28 days (for 19 days in the high-dose group). A control group was treated similarly with the vehicle, bidistilled water, only. The groups comprised 10 animals per sex, which were sacrificed after 28 days, respectively 19 days in the high-dose group, of treatment. Additional five rats per sex and group were treated accordingly and then allowed a 14 days treatment-free recovery period. Additional six rats per sex and group (three rats per sex in the control group) were treated accordingly and used for hemoglobin adduct analysis after EMS exposure. All animals survived until their scheduled necropsy. Treatment with EMS had a direct dose-dependent effect on food consumption and consequently on body weight at doses > or =20mg/kgbw/day in male rats and at > or =60 mg/kgbw/day in females rats. Hence, treatment with the high dose of 180 mg/kgbw/day had to be interrupted for 9 days after which, the animals were re-dosed at 120 mg/kgbw/day. This dose was also poorly tolerated over the remaining two treatment weeks causing again a marked reduction in food consumption and body weight. A dose of 60 mg/kgbw/day was moderately tolerated over 4 weeks treatment with mean daily food consumption and body weight distinctly lower than in controls. Primary targets of systemic toxicity were the hematopoietic system, thymolymphatic system and sexual organs. Characteristic changes in hematology parameters were decreased red blood cell counts, hematocrit, and hemoglobin concentration. White blood cell counts were also decreased due to reduced lymphocyte and granulocyte populations of each fraction. The corresponding histopathology findings were fatty atrophy of bone marrow and minimal hypocellularity of the white pulp of the spleen. Similarly, treatment with EMS caused an involution of the thymolymphatic system characterized by decreased organ weight of thymus, lymph nodes, and spleen microscopically associated with atrophy of the thymus and hypocellularity of Peyer's patches, lymph nodes and the white pulp of the spleen. The effects on sexual organs included lower organ weight/reduced size for testes, epididymides, seminal vesicles, prostate, and uterus. Tubular atrophy, single cell necrosis of the germ cells and in epididymides reduced spermatozoa were recorded microscopically. The described findings occurred at doses of 60 and 180/120 mg/kgbw/day and were dose-dependent with regard to incidence and severity. Other target organs were the pancreas (acinar cell vacuolation), thyroid gland (follicular cell hypertrophy), and salivary gland (secretory depletion of convoluted ducts). The systemic exposure to EMS was monitored by hemoglobin ethylvaline adduct measurement. The concentration of hemoglobin ethylvaline adducts was linear with the dose and accumulated 11-26-fold over the treatment period. In summary, decreases in food consumption and body weight were the dose-limiting effects of treatment with EMS. Organ toxicity was characterized by depression of cell proliferation (hematopoiesis and spermatogenesis) and changes suggestive of reduced metabolism and/or physiological imbalances (e.g. thymolymphatic system and thyroid gland) without signs of inflammatory or necrotic lesions. For some findings, especially the effects on the thymolymphatic system and sexual organs, it cannot be excluded that starvation-like condition contributed to the occurrence of such changes. The low dose of 20 mg/kgbw/day was basically free of adverse effects despite of a clear evidence for hemoglobin adducts.
Spiridonova, S I; Mukusheva, M K; Shubina, O A; Solomatin, V M; Epifanova, I E
2008-01-01
The results are presented from estimation of spatial distribution of 137Cs and 90Sr contamination densities in the areas of horses and sheep grazing within the Semipalatinsk Test Site. Dose burdens to various cohorts of the population living within the STS and consuming contaminated animal products are predicted. Doses of shepherds in the most contaminated pasture areas have been found to exceed the accepted limit (1 mSv/y). The conclusion is made about the need for further studies on the risk assessment of the STS population exposure above the accepted limits.
Azman, Andrew S.; Luquero, Francisco J.; Ciglenecki, Iza; Grais, Rebecca F.; Sack, David A.; Lessler, Justin
2015-01-01
Background In 2013, a stockpile of oral cholera vaccine (OCV) was created for use in outbreak response, but vaccine availability remains severely limited. Innovative strategies are needed to maximize the health impact and minimize the logistical barriers to using available vaccine. Here we ask under what conditions the use of one dose rather than the internationally licensed two-dose protocol may do both. Methods and Findings Using mathematical models we determined the minimum relative single-dose efficacy (MRSE) at which single-dose reactive campaigns are expected to be as or more effective than two-dose campaigns with the same amount of vaccine. Average one- and two-dose OCV effectiveness was estimated from published literature and compared to the MRSE. Results were applied to recent outbreaks in Haiti, Zimbabwe, and Guinea using stochastic simulations to illustrate the potential impact of one- and two-dose campaigns. At the start of an epidemic, a single dose must be 35%–56% as efficacious as two doses to avert the same number of cases with a fixed amount of vaccine (i.e., MRSE between 35% and 56%). This threshold decreases as vaccination is delayed. Short-term OCV effectiveness is estimated to be 77% (95% CI 57%–88%) for two doses and 44% (95% CI −27% to 76%) for one dose. This results in a one-dose relative efficacy estimate of 57% (interquartile range 13%–88%), which is above conservative MRSE estimates. Using our best estimates of one- and two-dose efficacy, we projected that a single-dose reactive campaign could have prevented 70,584 (95% prediction interval [PI] 55,943–86,205) cases in Zimbabwe, 78,317 (95% PI 57,435–100,150) in Port-au-Prince, Haiti, and 2,826 (95% PI 2,490–3,170) cases in Conakry, Guinea: 1.1 to 1.2 times as many as a two-dose campaign. While extensive sensitivity analyses were performed, our projections of cases averted in past epidemics are based on severely limited single-dose efficacy data and may not fully capture uncertainty due to imperfect surveillance data and uncertainty about the transmission dynamics of cholera in each setting. Conclusions Reactive vaccination campaigns using a single dose of OCV may avert more cases and deaths than a standard two-dose campaign when vaccine supplies are limited, while at the same time reducing logistical complexity. These findings should motivate consideration of the trade-offs between one- and two-dose campaigns in resource-constrained settings, though further field efficacy data are needed and should be a priority in any one-dose campaign. PMID:26305226
Wele, Asmita A.; Pendse, Nikhil U.; Takle, Shrikant P.; Burase, Raghunath V.; Patil, Sanjay V.; Bhalerao, Supriya; Harsulkar, Abhay M.
2015-01-01
Introduction: Vasarishta built upon Mritasanjeevani Sura (MS) is a polyherbal hydro-alcoholic anti-asthmatic formulation which is administered in a dose of 1 ml instead of standard dose 40 ml, generally advocated for any “Asava–Arishta” in Ayurveda. Aim: The present study was aimed at finding out rationale for the peculiar distillation process to manufacture MS followed by Sthapana process to make Vasarishta. It was further aimed to find out difference in Vasarishta samples manufactured by purely fermentation process and the peculiar method mentioned above. Materials and Methods: Three batches of MS and subsequently three batches of Vasarishta were prepared. Basic standardization and development of standard operating procedure for the same were achieved by doing pH, percentage of alcohol and total reducing sugar, specific gravity on both MS and Vasarishta, during and after completion of process. Finally, MS and Vasarishta (built upon MS) made in laboratory were compared with marketed samples of MS and Vasarishta using gas chromatography. Results: The types of alcohols and volatile acids in MS and Vasarishta, prepared in laboratory, are similar but the proportions differ, which is taken as an indicator of process standardization. Values of furfural, ethyl acetate, and 1-butanol in lab samples are within permissible limits as against the values of the market samples. Conclusions: The textual process for the production of Vasarishta proved to produce organoleptically acceptable product which is virtually free of toxic compounds such as furfural. PMID:27313419
2013-01-01
The most abundant polyphenol in green tea, epigallocatechin-3-gallate (EGCg), has recently received considerable attention due to the discovery of numerous health-promoting bioactivities. Despite reports of its poor oral bioavailability, EGCg has been included in many dietary supplement formulations. Conventional preformulation methods have been employed to improve the bioavailability of EGCg. However, these methods have limitations that hinder the development of EGCg as an effective therapeutic agent. In this study, we have utilized the basic concepts of crystal engineering and several crystallization techniques to screen for various solid crystalline forms of EGCg and evaluated the efficacy of crystal engineering for modulating the pharmacokinetics of EGCg. We synthesized and characterized seven previously undescribed crystal forms of EGCg including the pure crystal structure of EGCg. The aqueous solubility profiles of four new EGCg cocrystals were determined. These cocrystals were subsequently dosed at 100 mg EGCg per kg body weight in rats, and the plasma levels were monitored over the course of eight hours following the single oral dose. Two of the EGCg cocrystals were found to exhibit modest improvements in relative bioavailability. Further, cocrystallization resulted in marked effects on pharmacokinetic parameters including Cmax, Tmax, area under curve, relative bioavailability, and apparent terminal half-life. Our findings suggest that modulation of the pharmacokinetic profile of EGCg is possible using cocrystallization and that it offers certain opportunities that could be useful during its development as a therapeutic agent. PMID:23730870
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chau, Ricky; Teo, Peter; Kam, Michael
The aim of this study is to evaluate the deficiencies in target coverage and organ protection of 2-dimensional radiation therapy (2DRT) in the treatment of advanced T-stage (T3-4) nasopharyngeal carcinoma (NPC), and assess the extent of improvement that could be achieved with intensity modulated radiation therapy (IMRT), with special reference to of the dose to the planning organ-at-risk volume (PRV) of the brainstem and spinal cord. A dosimetric study was performed on 10 patients with advanced T-stage (T3-4 and N0-2) NPC. Computer tomography (CT) images of 2.5-mm slice thickness of the head and neck were acquired with the patient immobilizedmore » in semi-extended-head position. A 2D plan based on Ho's technique, and an IMRT plan based on a 7-coplanar portals arrangement, were established for each patient. 2DRT was planned with the field borders and shielding drawn on the simulator radiograph with reference to bony landmarks, digitized, and entered into a planning computer for reconstruction of the 3D dose distribution. The 2DRT and IMRT treatment plans were evaluated and compared with respect to the dose-volume histograms (DVHs) of the targets and the organs-at-risk (OARs), tumor control probability (TCP), and normal tissue complication probabilities (NTCPs). With IMRT, the dose coverage of the target was superior to that of 2DRT. The mean minimum dose of the GTV and PTV were increased from 33.7 Gy (2DRT) to 62.6 Gy (IMRT), and 11.9 Gy (2DRT) to 47.8 Gy (IMRT), respectively. The D{sub 95} of the GTV and PTV were also increased from 57.1 Gy (2DRT) to 67 Gy (IMRT), and 45 Gy (2DRT) to 63.6 Gy (IMRT), respectively. The TCP was substantially increased to 78.5% in IMRT. Better protection of the critical normal organs was also achieved with IMRT. The mean maximum dose delivered to the brainstem and spinal cord were reduced significantly from 61.8 Gy (2DRT) to 52.8 Gy (IMRT) and 56 Gy (2DRT) to 43.6 Gy (IMRT), respectively, which were within the conventional dose limits of 54 Gy for brainstem and of 45 Gy for spinal cord. The mean maximum doses deposited on the PRV of the brainstem and spinal cord were 60.7 Gy and 51.6 Gy respectively, which were above the conventional dose limits. For the chiasm, the mean dose maximum and the dose to 5% of its volume were reduced from 64.3 Gy (2DRT) to 53.7 Gy (IMRT) and from 62.8 Gy (2DRT) to 48.7 Gy (IMRT), respectively, and the corresponding NTCP was reduced from 18.4% to 2.1%. For the temporal lobes, the mean dose to 10% of its volume (about 4.6 cc) was reduced from 63.8 Gy (2DRT) to 55.4 Gy (IMRT) and the NTCP was decreased from 11.7% to 3.4%. The therapeutic ratio for T3-4 NPC tumors can be significantly improved with IMRT treatment technique due to improvement both in target coverage and the sparing of the critical normal organ. Although the maximum doses delivered to the brainstem and spinal cord in IMRT can be kept at or below their conventional dose limits, the maximum doses deposited on the PRV often exceed these limits due to the close proximity between the target and OARs. In other words, ideal dosimetric considerations cannot be fulfilled in IMRT planning for T3-4 NPC tumors. A compromise of the maximal dose limit to the PRV of the brainstem and spinal cord would need be accepted if dose coverage to the targets is not to be unacceptably compromised. Dosimetric comparison with 2DRT plans show that these dose limits to PRV were also frequently exceeded in 2DRT plans for locally advanced NPC. A dedicated retrospective study on the incidence of clinical injury to neurological organs in a large series of patients with T3-4 NPC treated by 2DRT may provide useful reference data in exploring how far the PRV dose constraints may be relaxed, to maximize the target coverage without compromising the normal organ function.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guan, Fada; Peeler, Christopher; Taleei, Reza
Purpose: The motivation of this study was to find and eliminate the cause of errors in dose-averaged linear energy transfer (LET) calculations from therapeutic protons in small targets, such as biological cell layers, calculated using the GEANT 4 Monte Carlo code. Furthermore, the purpose was also to provide a recommendation to select an appropriate LET quantity from GEANT 4 simulations to correlate with biological effectiveness of therapeutic protons. Methods: The authors developed a particle tracking step based strategy to calculate the average LET quantities (track-averaged LET, LET{sub t} and dose-averaged LET, LET{sub d}) using GEANT 4 for different tracking stepmore » size limits. A step size limit refers to the maximally allowable tracking step length. The authors investigated how the tracking step size limit influenced the calculated LET{sub t} and LET{sub d} of protons with six different step limits ranging from 1 to 500 μm in a water phantom irradiated by a 79.7-MeV clinical proton beam. In addition, the authors analyzed the detailed stochastic energy deposition information including fluence spectra and dose spectra of the energy-deposition-per-step of protons. As a reference, the authors also calculated the averaged LET and analyzed the LET spectra combining the Monte Carlo method and the deterministic method. Relative biological effectiveness (RBE) calculations were performed to illustrate the impact of different LET calculation methods on the RBE-weighted dose. Results: Simulation results showed that the step limit effect was small for LET{sub t} but significant for LET{sub d}. This resulted from differences in the energy-deposition-per-step between the fluence spectra and dose spectra at different depths in the phantom. Using the Monte Carlo particle tracking method in GEANT 4 can result in incorrect LET{sub d} calculation results in the dose plateau region for small step limits. The erroneous LET{sub d} results can be attributed to the algorithm to determine fluctuations in energy deposition along the tracking step in GEANT 4. The incorrect LET{sub d} values lead to substantial differences in the calculated RBE. Conclusions: When the GEANT 4 particle tracking method is used to calculate the average LET values within targets with a small step limit, such as smaller than 500 μm, the authors recommend the use of LET{sub t} in the dose plateau region and LET{sub d} around the Bragg peak. For a large step limit, i.e., 500 μm, LET{sub d} is recommended along the whole Bragg curve. The transition point depends on beam parameters and can be found by determining the location where the gradient of the ratio of LET{sub d} and LET{sub t} becomes positive.« less
Radiolysis of paracetamol in dilute aqueous solution
NASA Astrophysics Data System (ADS)
Szabó, László; Tóth, Tünde; Homlok, Renáta; Takács, Erzsébet; Wojnárovits, László
2012-09-01
Using radiolytic experiments hydroxyl radical (main reactant in advanced oxidation processes) was shown to effectively destroy paracetamol molecules. The basic reaction is attachment to the ring. The hydroxy-cyclohexadienyl radical produced in the further reactions may transform to hydroxylated paracetamol derivatives or to quinone type molecules and acetamide. The initial efficiency of aromatic ring destruction in the absence of dissolved O2 is c.a. 10%. The efficiency is 2-3 times higher in the presence of O2 due to its reaction with intermediate hydroxy-cyclohexadienyl radical and the subsequent ring destruction reactions through peroxi radical. Upon irradiation the toxicity of solutions at low doses increases with the dose and then at higher doses it decreases. This is due to formation of compounds with higher toxicity than paracetamol (e.g. acetamide, hidroquinone). These products, however, are highly sensitive to irradiation and degrade easily.
1982-01-01
We have examined the secretogogue responsiveness and the pattern of secretory proteins produced by a transplantable rat pancreatic acinar cell tumor. Dispersed tumor cells were found to discharge secretory proteins in vitro when incubated with hormones that act on four different classes of receptors: carbamylcholine, caerulein, secretin- vasoactive intestinal peptide, and bombesin. With all hormones tested, maximal discharge from tumor cells was only about one-half that of control pancreatic lobules, but occurred at the same dose optima except for secretin, whose dose optimum was 10-fold higher. Biochemical analysis of secretory proteins discharged by the tumor cells was carried out by crossed immunoelectrophoresis and by two-dimensional isoelectric focusing-SDS polyacrylamide gel electrophoresis. To establish a baseline for comparison, secretory proteins from normal rat pancreas were identified according to enzymatic activity and correlated with migration position on two-dimensional gels. Our results indicate that a group of basic polypeptides including proelastase, basic trypsinogen, basic chymotrypsinogen, and ribonuclease, two out of three forms of procarboxypeptidase B, and the major lipase species were greatly reduced or absent in tumor cell secretion. In contrast, the amount of acidic chymotrypsinogen was notably increased compared with normal acinar cells. Although the acinar tumor cells are highly differentiated cytologically and express functional receptors for several classes of pancreatic secretagogues, they show quantitative and qualitative differences when compared with normal pancreas with regard to their production of secretory proteins. PMID:6185502
Immunotoxins: magic bullets or misguided missiles?
Vitetta, E S; Thorpe, P E; Uhr, J W
1993-05-01
Thirteen years have passed since specific in vitro and in vivo killing of tumour cells by immunotoxins was first described. Why, then, has it taken so long to determine whether these drugs will have a major impact on the treatment of cancer, AIDS and autoimmune disease? The answer is that the transfer of basic discoveries to the clinic is a slow, multistep, interdisciplinary process. Thus, immunotoxin molecules must be designed and redesigned by the basic scientist depending on the efficacy and toxicity shown in vitro and in relevant experimental models. Next, each version must be evaluated by clinicians in humans through a lengthy process (1-3 years) in which the dose regimen is optimized and in which new problems and issues frequently emerge. These problems must again be modelled and studied in animals before additional clinical trials are initiated. In this article, Ellen Vitetta and colleagues discuss both basic and clinical aspects of the development of immunotoxin therapy.
Respirators, internal dose, and Oyster Creek
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michal, R.
1996-06-01
This article looks at the experience of Oyster Creek in relaxing the requirements for the use of respirators in all facets of plant maintenance, on the overall dose received by plant maintenance personnel. For Roger Shaw, director of radiological controls for three years at GPU Nuclear Corporation`s Oyster Creek nuclear plant the correct dose balance is determined on a job-by-job basis: Does the job require a respirator, which is an effective means of decreasing worker inhalation of airborne radioactive particles? Will wearing a respirator slow down a worker, consequently increasing whole body radiation exposure by prolonging the time spent inmore » fields of high external radiation? How does respiratory protection affect worker safety and to what degree? While changes to the Nuclear Regulatory Commission`s 10CFR20 have updated the radiation protection requirements for the nuclear industry, certain of the revisions have been directed specifically at reducing worker dose, Shaw said. {open_quotes}It basically delineates that dose is dose,{close_quotes} Shaw said, {open_quotes}regardless of whether it is acquired externally or internally.{close_quotes} The revision of Part 20 changed the industry`s attitude toward internal dose, which had always been viewed negatively. {open_quotes}Internal dose was always seen as preventable by wearing respirators and by using engineering techniques such as ventilation control and decontamination,{close_quotes} Shaw said, {open_quotes}whereas external dose, although reduced where practical, was seen as a fact of the job.{close_quotes}« less
Basic Emotions in Human Neuroscience: Neuroimaging and Beyond.
Celeghin, Alessia; Diano, Matteo; Bagnis, Arianna; Viola, Marco; Tamietto, Marco
2017-01-01
The existence of so-called 'basic emotions' and their defining attributes represents a long lasting and yet unsettled issue in psychology. Recently, neuroimaging evidence, especially related to the advent of neuroimaging meta-analytic methods, has revitalized this debate in the endeavor of systems and human neuroscience. The core theme focuses on the existence of unique neural bases that are specific and characteristic for each instance of basic emotion. Here we review this evidence, outlining contradictory findings, strengths and limits of different approaches. Constructionism dismisses the existence of dedicated neural structures for basic emotions, considering that the assumption of a one-to-one relationship between neural structures and their functions is central to basic emotion theories. While these critiques are useful to pinpoint current limitations of basic emotions theories, we argue that they do not always appear equally generative in fostering new testable accounts on how the brain relates to affective functions. We then consider evidence beyond PET and fMRI, including results concerning the relation between basic emotions and awareness and data from neuropsychology on patients with focal brain damage. Evidence from lesion studies are indeed particularly informative, as they are able to bring correlational evidence typical of neuroimaging studies to causation, thereby characterizing which brain structures are necessary for, rather than simply related to, basic emotion processing. These other studies shed light on attributes often ascribed to basic emotions, such as automaticity of perception, quick onset, and brief duration. Overall, we consider that evidence in favor of the neurobiological underpinnings of basic emotions outweighs dismissive approaches. In fact, the concept of basic emotions can still be fruitful, if updated to current neurobiological knowledge that overcomes traditional one-to-one localization of functions in the brain. In particular, we propose that the structure-function relationship between brain and emotions is better described in terms of pluripotentiality, which refers to the fact that one neural structure can fulfill multiple functions, depending on the functional network and pattern of co-activations displayed at any given moment.
Study of runaway electrons using dosimetry of hard x-ray radiations in Damavand tokamak
NASA Astrophysics Data System (ADS)
Rasouli, C.; Pourshahab, B.; Hosseini Pooya, S. M.; Orouji, T.; Rasouli, H.
2014-05-01
In this work several studies have been conducted on hard x-ray emissions of Damavand tokamak based on radiation dosimetry using the Thermoluminescence method. The goal was to understand interactions of runaway electrons with plasma particles, vessel wall, and plasma facing components. Total of 354 GR-200 (LiF:Mg,Cu,P) thermoluminescence dosimeter (TLD) crystals have been placed on 118 points - three TLDs per point - to map hard x-ray radiation doses on the exterior of the vacuum vessel. Results show two distinctive levels of x-ray radiations doses on the exterior of the vessel. The low-dose area on which measured dose is about 0.5 mSv/shot. In the low-dose area there is no particular component inside the vessel. On the contrary, on high-dose area of the vessel, x-ray radiations dose exceeds 30 mSv/shot. The high-dose area coincides with the position of limiters, magnetic probe ducts, and vacuum vessel intersections. Among the high-dose areas, the highest level of dose is measured in the position of the limiter, which could be due to its direct contact with the plasma column and with runaway electrons. Direct collisions of runaway electrons with the vessel wall and plasma facing components make a major contribution for production of hard x-ray photons in Damavand tokamak.
Study of runaway electrons using dosimetry of hard x-ray radiations in Damavand tokamak.
Rasouli, C; Pourshahab, B; Hosseini Pooya, S M; Orouji, T; Rasouli, H
2014-05-01
In this work several studies have been conducted on hard x-ray emissions of Damavand tokamak based on radiation dosimetry using the Thermoluminescence method. The goal was to understand interactions of runaway electrons with plasma particles, vessel wall, and plasma facing components. Total of 354 GR-200 (LiF:Mg,Cu,P) thermoluminescence dosimeter (TLD) crystals have been placed on 118 points--three TLDs per point--to map hard x-ray radiation doses on the exterior of the vacuum vessel. Results show two distinctive levels of x-ray radiations doses on the exterior of the vessel. The low-dose area on which measured dose is about 0.5 mSv/shot. In the low-dose area there is no particular component inside the vessel. On the contrary, on high-dose area of the vessel, x-ray radiations dose exceeds 30 mSv/shot. The high-dose area coincides with the position of limiters, magnetic probe ducts, and vacuum vessel intersections. Among the high-dose areas, the highest level of dose is measured in the position of the limiter, which could be due to its direct contact with the plasma column and with runaway electrons. Direct collisions of runaway electrons with the vessel wall and plasma facing components make a major contribution for production of hard x-ray photons in Damavand tokamak.
Evaluation of effective dose with chest digital tomosynthesis system using Monte Carlo simulation
NASA Astrophysics Data System (ADS)
Kim, Dohyeon; Jo, Byungdu; Lee, Youngjin; Park, Su-Jin; Lee, Dong-Hoon; Kim, Hee-Joung
2015-03-01
Chest digital tomosynthesis (CDT) system has recently been introduced and studied. This system offers the potential to be a substantial improvement over conventional chest radiography for the lung nodule detection and reduces the radiation dose with limited angles. PC-based Monte Carlo program (PCXMC) simulation toolkit (STUK, Helsinki, Finland) is widely used to evaluate radiation dose in CDT system. However, this toolkit has two significant limits. Although PCXMC is not possible to describe a model for every individual patient and does not describe the accurate X-ray beam spectrum, Geant4 Application for Tomographic Emission (GATE) simulation describes the various size of phantom for individual patient and proper X-ray spectrum. However, few studies have been conducted to evaluate effective dose in CDT system with the Monte Carlo simulation toolkit using GATE. The purpose of this study was to evaluate effective dose in virtual infant chest phantom of posterior-anterior (PA) view in CDT system using GATE simulation. We obtained the effective dose at different tube angles by applying dose actor function in GATE simulation which was commonly used to obtain the medical radiation dosimetry. The results indicated that GATE simulation was useful to estimate distribution of absorbed dose. Consequently, we obtained the acceptable distribution of effective dose at each projection. These results indicated that GATE simulation can be alternative method of calculating effective dose in CDT applications.
Brooks, Antone L
2015-04-01
This commentary provides a very brief overview of the book "A History of the United States Department of Energy (DOE) Low Dose Radiation Research Program: 1998-2008" ( http://lowdose.energy.gov ). The book summarizes and evaluates the research progress, publications and impact of the U.S. Department of Energy Low Dose Radiation Research Program over its first 10 years. The purpose of this book was to summarize the impact of the program's research on the current thinking and low-dose paradigms associated with the radiation biology field and to help stimulate research on the potential adverse and/or protective health effects of low doses of ionizing radiation. In addition, this book provides a summary of the data generated in the low dose program and a scientific background for anyone interested in conducting future research on the effects of low-dose or low-dose-rate radiation exposure. This book's exhaustive list of publications coupled with discussions of major observations should provide a significant resource for future research in the low-dose and dose-rate region. However, because of space limitations, only a limited number of critical references are mentioned. Finally, this history book provides a list of major advancements that were accomplished by the program in the field of radiation biology, and these bulleted highlights can be found in last part of chapters 4-10.
Translational PK/PD of Anti-Infective Therapeutics
Rathi, Chetan; Lee, Richard E.; Meibohm, Bernd
2016-01-01
Translational PK/PD modeling has emerged as a critical technique for quantitative analysis of the relationship between dose, exposure and response of antibiotics. By combining model components for pharmacokinetics, bacterial growth kinetics and concentration-dependent drug effects, these models are able to quantitatively capture and simulate the complex interplay between antibiotic, bacterium and host organism. Fine-tuning of these basic model structures allows to further account for complicating factors such as resistance development, combination therapy, or host responses. With this tool set at hand, mechanism-based PK/PD modeling and simulation allows to develop optimal dosing regimens for novel and established antibiotics for maximum efficacy and minimal resistance development. PMID:27978987
Effects of dose scaling on delivery quality assurance in tomotherapy
Nalichowski, Adrian; Burmeister, Jay
2012-01-01
Delivery quality assurance (DQA) of tomotherapy plans is routinely performed with silver halide film which has a limited range due to the effects of saturation. DQA plans with dose values exceeding this limit require the dose of the entire plan to be scaled downward if film is used, to evaluate the dose distribution in two dimensions. The potential loss of fidelity between scaled and unscaled DQA plans as a function of dose scaling is investigated. Three treatment plans for 12 Gy fractions designed for SBRT of the lung were used to create DQA procedures that were scaled between 100% and 10%. The dose was measured with an ionization chamber array and compared to values from the tomotherapy treatment planning system. Film and cylindrical ion chamber measurements were also made for one patient for scaling factors of 50% to 10% to compare with the ionization chamber array measurements. The array results show the average gamma pass rate is ≥99% from 100% to 30% scaling. The average gamma pass rate falls to 93.6% and 51.1% at 20% and 10% scaling, respectively. Film analysis yields similar pass rates. Cylindrical ion chambers did not exhibit significant variation with dose scaling, but only represent points in the low gradient region of the dose distribution. Scaling the dose changes the mechanics of the radiation delivery, as well as the signal‐to‐noise ratio. Treatment plans which exhibit parameters that differ significantly from those common to DQA plans studied in this paper may exhibit different behavior. Dose scaling should be limited to the smallest degree possible. Planar information, such as that from film or a detector array, is required. The results show that it is not necessary to perform both a scaled and unscaled DQA plan for the treatment plans considered here. PACS numbers: 87.55.km, 87.55.Qr PMID:22231213
Hull, Brynley P; Menzies, Robert; Macartney, Kristine; McIntyre, Peter B
2013-04-08
Strict age limits for receipt of rotavirus vaccines and simultaneous use of vaccines requiring two (Rotarix(®)) and three (RotaTeq(®)) doses in Australia may impact on coverage and timeliness of other vaccines in the infant schedule. Using data from the Australian Childhood Immunisation Register (ACIR), coverage and timeliness of rotavirus vaccines and changes in timeliness of other infant vaccines following rotavirus vaccine introduction was examined, with particular emphasis on Indigenous infants in whom coverage is less optimal. Final dose rotavirus coverage reached 83% within 21 months of program commencement but remained 7% lower than other vaccines due in infancy. Coverage was 11-17% lower in Indigenous infants. Adherence to the first dose upper age limits for rotavirus vaccine was high with >97% of children vaccinated by the recommended age, but for subsequent rotavirus doses, receipt beyond the upper age limits was more common, especially in Indigenous children. Following rotavirus vaccine introduction, there were improvements in timeliness of receipt of all doses of DTPa-containing and 7-valent pneumococcal conjugate vaccines. High population coverage can be attained with rotavirus vaccines, even with adherence to strict upper age restrictions for vaccine dose administration. Rotavirus vaccine introduction appears to have impacted upon the timeliness of other concomitantly scheduled vaccines. These factors should be considered when rotavirus programs are introduced. Copyright © 2013 Elsevier Ltd. All rights reserved.
RADIOACTIVE CONTAMINATION OF FOODS. PROBLEMS IN THE FOOD CONSUMPTION OF THE ITALIAN POPULATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferro-Luzzi, A.; Mariani, A.
The aspects of health physics that are basically applications of physics are reviewed. Units of radiation measurement, RBE, permissible doses, personnel monitoring, applications of radiation spectrometry, and measurement of body activity are considered, as well as the release, dispersion, and deposition of radioactive material in reactor accidents. 140 references. (D.C.W.)
Protracted Low-Dose Ionizing Radiation Effects upon Primate Performance
1977-12-01
61 G. Dosimetry ................................ ............. 74 NTiS Whife Sectle ) U A N O U C E D JUSTIFICATION...AECL facility. Standard dosimetry techniques were utilized during radiation expo- sur.. In addition, extensive preexposure calibration was conducted...During each of the epochs, the five basic variables were deter- mined. These calculations were accomplished on an analog computer, Electronics Associates
The development of response surface pathway design to reduce animal numbers in toxicity studies
2014-01-01
Background This study describes the development of Response Surface Pathway (RSP) design, assesses its performance and effectiveness in estimating LD50, and compares RSP with Up and Down Procedures (UDPs) and Random Walk (RW) design. Methods A basic 4-level RSP design was used on 36 male ICR mice given intraperitoneal doses of Yessotoxin. Simulations were performed to optimise the design. A k-adjustment factor was introduced to ensure coverage of the dose window and calculate the dose steps. Instead of using equal numbers of mice on all levels, the number of mice was increased at each design level. Additionally, the binomial outcome variable was changed to multinomial. The performance of the RSP designs and a comparison of UDPs and RW were assessed by simulations. The optimised 4-level RSP design was used on 24 female NMRI mice given Azaspiracid-1 intraperitoneally. Results The in vivo experiment with basic 4-level RSP design estimated the LD50 of Yessotoxin to be 463 μg/kgBW (95% CI: 383–535). By inclusion of the k-adjustment factor with equal or increasing numbers of mice on increasing dose levels, the estimate changed to 481 μg/kgBW (95% CI: 362–566) and 447 μg/kgBW (95% CI: 378–504 μg/kgBW), respectively. The optimised 4-level RSP estimated the LD50 to be 473 μg/kgBW (95% CI: 442–517). A similar increase in power was demonstrated using the optimised RSP design on real Azaspiracid-1 data. The simulations showed that the inclusion of the k-adjustment factor, reduction in sample size by increasing the number of mice on higher design levels and incorporation of a multinomial outcome gave estimates of the LD50 that were as good as those with the basic RSP design. Furthermore, optimised RSP design performed on just three levels reduced the number of animals from 36 to 15 without loss of information, when compared with the 4-level designs. Simulated comparison of the RSP design with UDPs and RW design demonstrated the superiority of RSP. Conclusion Optimised RSP design reduces the number of animals needed. The design converges rapidly on the area of interest and is at least as efficient as both the UDPs and RW design. PMID:24661560
Dosing Accuracy of Insulin Aspart FlexPens After Transport Through the Pneumatic Tube System.
Ward, Leah G; Heckman, Michael G; Warren, Amy I; Tran, Kimberly
2013-01-01
The purpose of this study was to evaluate whether transporting insulin aspart FlexPens via a pneumatic tube system affects the dosing accuracy of the pens. A total of 115 Novo Nordisk FlexPens containing insulin aspart were randomly assigned to be transported via a pneumatic tube system (n = 92) or to serve as the control (n = 23). Each pen was then randomized to 10 international unit (IU) doses (n = 25) or 30 IU doses (n = 67), providing 600 and 603 doses, respectively, for the pneumatic tube group. The control group also received random assignment to 10 IU doses (n = 6) or 30 IU doses (n = 17), providing 144 and 153 doses, respectively. Each dose was expelled using manufacturer instructions. Weights were recorded, corrected for specific gravity, and evaluated based on acceptable International Organization for Standardization (ISO) dosing limits. In the group of pens transported through the pneumatic tube system, none of the 600 doses of 10 IU (0.0%; 95% CI, 0.0 to 0.6) and none of the 603 doses of 30 IU (0.0%; 95% CI, 0.0 to 0.6) fell outside of the range of acceptable weights. Correspondingly, in the control group, none of the 144 doses at 10 IU (0.0%; 95% CI, 0.0 to 2.5) and none of the 153 doses at 30 IU (0.0%; 95% CI, 0.0 to 2.4) were outside of acceptable ISO limits. Transportation via pneumatic tube system does not appear to compromise dosing accuracy. Hospital pharmacies may rely on the pneumatic tube system for timely and accurate transport of insulin aspart FlexPens.
High-Dose Vitamin C (PDQ®)—Health Professional Version
High-dose vitamin C, with and without conventional cancer therapies, appeared promising in early studies and was well tolerated. However, these studies have several limitations due to lack of rigor in trial design. Get detailed information about high-dose vitamin C in cancer in this clinician summary.
BENCHMARK DOSES FOR CHEMICAL MIXTURES: EVALUATION OF A MIXTURE OF 18 PHAHS.
Benchmark doses (BMDs), defined as doses of a substance that are expected to result in a pre-specified level of "benchmark" response (BMR), have been used for quantifying the risk associated with exposure to environmental hazards. The lower confidence limit of the BMD is used as...
Tri-partite complex for axonal transport drug delivery achieves pharmacological effect
2010-01-01
Background Targeted delivery of pharmaceutical agents into selected populations of CNS (Central Nervous System) neurons is an extremely compelling goal. Currently, systemic methods are generally used for delivery of pain medications, anti-virals for treatment of dermatomal infections, anti-spasmodics, and neuroprotectants. Systemic side effects or undesirable effects on parts of the CNS that are not involved in the pathology limit efficacy and limit clinical utility for many classes of pharmaceuticals. Axonal transport from the periphery offers a possible selective route, but there has been little progress towards design of agents that can accomplish targeted delivery via this intraneural route. To achieve this goal, we developed a tripartite molecular construction concept involving an axonal transport facilitator molecule, a polymer linker, and a large number of drug molecules conjugated to the linker, then sought to evaluate its neurobiology and pharmacological behavior. Results We developed chemical synthesis methodologies for assembling these tripartite complexes using a variety of axonal transport facilitators including nerve growth factor, wheat germ agglutinin, and synthetic facilitators derived from phage display work. Loading of up to 100 drug molecules per complex was achieved. Conjugation methods were used that allowed the drugs to be released in active form inside the cell body after transport. Intramuscular and intradermal injection proved effective for introducing pharmacologically effective doses into selected populations of CNS neurons. Pharmacological efficacy with gabapentin in a paw withdrawal latency model revealed a ten fold increase in half life and a 300 fold decrease in necessary dose relative to systemic administration for gabapentin when the drug was delivered by axonal transport using the tripartite vehicle. Conclusion Specific targeting of selected subpopulations of CNS neurons for drug delivery by axonal transport holds great promise. The data shown here provide a basic framework for the intraneural pharmacology of this tripartite complex. The pharmacologically efficacious drug delivery demonstrated here verify the fundamental feasibility of using axonal transport for targeted drug delivery. PMID:20085661
Analysis and evaluation for consumer goods containing NORM in Korea.
Jang, Mee; Chung, Kun Ho; Lim, Jong Myoung; Ji, Young Yong; Kim, Chang Jong; Kang, Mun Ja
2017-08-01
We analyzed the consumer goods containing NORM by ICP-MS and evaluated the external dose. To evaluate the external dose, we assumed the small room model as irradiation scenario and calculated the specific effective dose rate using MCNPX code. The external doses for twenty goods are less than 1 mSv considering the specific effective dose rates and usage quantities. However, some of them have relatively high dose and the activity concentration limits are necessary as a screening tool. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Krzyścin, Janusz W.; Sobolewski, Piotr S.
2018-01-01
Erythemal daily doses measured at the Polish Polar Station, Hornsund (77°00' N, 15°33' E), for the periods 1996-2001 and 2005-2016 are homogenized using yearly calibration constants derived from the comparison of observed doses for cloudless conditions with the corresponding doses calculated by radiative transfer (RT) simulations. Modeled all-sky doses are calculated by the multiplication of cloudless RT doses by the empirical cloud modification factor dependent on the daily sunshine duration. An all-sky model is built using daily erythemal doses measured in the period 2005-2006-2007. The model is verified by comparisons with the 1996-1997-1998 and 2009-2010-2011 measured data. The daily doses since 1983 (beginning of the proxy data) are reconstructed using the all-sky model with the historical data of the column ozone from satellite measurements (SBUV merged ozone data set), the snow depth (for ground albedo estimation), and the observed daily sunshine duration at the site. Trend analyses of the monthly and yearly time series comprised of the reconstructed and observed doses do not reveal a statistically significant trend in the period 1983-2016. The trends based on the observed data only (1996-2001 and 2005-2016) show declining tendency (about -1 % per year) in the monthly mean of daily erythemal doses in May and June, and in the yearly sum of daily erythemal doses. An analysis of sources of the yearly dose variability since 1983 shows that cloud cover changes are a basic driver of the long-term UV changes at the site.
Fried, P A; Watkinson, B
2000-01-01
Visuoperceptual performance was examined in 146 9- to 12-year old children for whom prenatal exposure to marihuana and cigarettes had been ascertained. The subjects, participants in an ongoing longitudinal study, were from a low-risk, predominantly middle class sample. The tasks ranged in complexity from those that required basic visuoperceptual skills to those that required considerable integration and cognitive manipulation of such skills. Trend analysis revealed a dose dependent negative association between prenatal cigarette exposure and an overall score reflecting basic visuoperceptual functioning. This association remained after consideration of potential prenatal confounds, pre- and postnatal secondhand smoke exposure, and the nonperceptual demands of the tasks. This poorer performance in the basic visuoperceptual domain underlay a poorer performance in more complex visuoperceptual tasks among the offspring of cigarette smokers. In contrast, prenatal marihuana exposure was not associated with basic visuoperceptual functioning but was negatively associated with performance in visual problem solving situations. The interpretation of the marihuana findings is discussed in relation to a "top-down" integrative ability associated with executive function, the extant prefrontal literature, and earlier observations of this sample.
WE-A-304-01: Strategies and Technologies for Cranial Radiosurgery Planning: MLC-Based Linac
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, G.
2015-06-15
The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Futuremore » directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.« less
WE-A-304-02: Strategies and Technologies for Cranial Radiosurgery Planning: Gamma Knife
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schlesinger, D.
2015-06-15
The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Futuremore » directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monjazeb, Arta M., E-mail: arta.monjazeb@ucdmc.ucdavis.edu; Ayala, Deandra; Jensen, Courtney
2012-02-01
Objectives: To describe the results of a Phase I dose escalation trial for newly diagnosed glioblastoma multiforme (GBM) using a hypofractionated concurrent intensity-modulated radiotherapy (IMRT) boost. Methods: Twenty-one patients were enrolled between April 1999 and August 2003. Radiotherapy consisted of daily fractions of 1.8 Gy with a concurrent boost of 0.7 Gy (total 2.5 Gy daily) to a total dose of 70, 75, or 80 Gy. Concurrent chemotherapy was not permitted. Seven patients were enrolled at each dose and dose limiting toxicities were defined as irreversible Grade 3 or any Grade 4-5 acute neurotoxicity attributable to radiotherapy. Results: All patientsmore » experienced Grade 1 or 2 acute toxicities. Acutely, 8 patients experienced Grade 3 and 1 patient experienced Grade 3 and 4 toxicities. Of these, only two reversible cases of otitis media were attributable to radiotherapy. No dose-limiting toxicities were encountered. Only 2 patients experienced Grade 3 delayed toxicity and there was no delayed Grade 4 toxicity. Eleven patients requiring repeat resection or biopsy were found to have viable tumor and radiation changes with no cases of radionecrosis alone. Median overall and progression-free survival for this cohort were 13.6 and 6.5 months, respectively. One- and 2-year survival rates were 57% and 19%. At recurrence, 15 patients received chemotherapy, 9 underwent resection, and 5 received radiotherapy. Conclusions: Using a hypofractionated concurrent IMRT boost, we were able to safely treat patients to 80 Gy without any dose-limiting toxicity. Given that local failure still remains the predominant pattern for GBM patients, a trial of dose escalation with IMRT and temozolomide is warranted.« less
Poet, T S; Schlosser, P M; Rodriguez, C E; Parod, R J; Rodwell, D E; Kirman, C R
2016-04-01
The developmental effects of NMP are well studied in Sprague-Dawley rats following oral, inhalation, and dermal routes of exposure. Short-term and chronic occupational exposure limit (OEL) values were derived using an updated physiologically based pharmacokinetic (PBPK) model for NMP, along with benchmark dose modeling. Two suitable developmental endpoints were evaluated for human health risk assessment: (1) for acute exposures, the increased incidence of skeletal malformations, an effect noted only at oral doses that were toxic to the dam and fetus; and (2) for repeated exposures to NMP, changes in fetal/pup body weight. Where possible, data from multiple studies were pooled to increase the predictive power of the dose-response data sets. For the purposes of internal dose estimation, the window of susceptibility was estimated for each endpoint, and was used in the dose-response modeling. A point of departure value of 390 mg/L (in terms of peak NMP in blood) was calculated for skeletal malformations based on pooled data from oral and inhalation studies. Acceptable dose-response model fits were not obtained using the pooled data for fetal/pup body weight changes. These data sets were also assessed individually, from which the geometric mean value obtained from the inhalation studies (470 mg*hr/L), was used to derive the chronic OEL. A PBPK model for NMP in humans was used to calculate human equivalent concentrations corresponding to the internal dose point of departure values. Application of a net uncertainty factor of 20-21, which incorporates data-derived extrapolation factors, to the point of departure values yields short-term and chronic occupational exposure limit values of 86 and 24 ppm, respectively. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Analyses of risks associated with radiation exposure from past major solar particle events
NASA Technical Reports Server (NTRS)
Weyland, Mark D.; Atwell, William; Cucinotta, Francis A.; Wilson, John W.; Hardy, Alva C.
1991-01-01
Radiation exposures and cancer induction/mortality risks were investigated for several major solar particle events (SPE's). The SPE's included are: February 1956, November 1960, August 1972, October 1989, and the September, August, and October 1989 events combined. The three 1989 events were treated as one since all three could affect a single lunar or Mars mission. A baryon transport code was used to propagate particles through aluminum and tissue shield materials. A free space environment was utilized for all calculations. Results show the 30-day blood forming organs (BFO) limit of 25 rem was surpassed by all five events using 10 g/sq cm of shielding. The BFO limit is based on a depth dose of 5 cm of tissue, while a more detailed shield distribution of the BFO's was utilized. A comparison between the 5 cm depth dose and the dose found using the BFO shield distribution shows that the 5 cm depth value slightly higher than the BFO dose. The annual limit of 50 rem was exceeded by the August 1972, October 1989, and the three combined 1989 events with 5 g/sq cm of shielding. Cancer mortality risks ranged from 1.5 to 17 percent at 1 g/sq cm and 0.5 to 1.1 percent behind 10 g/sq cm of shielding for five events. These ranges correspond to those for a 45 year old male. It is shown that secondary particles comprise about 1/3 of the total risk at 10 g/sq cm of shielding. Utilizing a computerized Space Shuttle shielding model to represent a typical spacecraft configuration in free space at the August 1972 SPE, average crew doses exceeded the BFO dose limit.
Low-voltage chest CT: another way to reduce the radiation dose in asbestos-exposed patients.
Macía-Suárez, D; Sánchez-Rodríguez, E; Lopez-Calviño, B; Diego, C; Pombar, M
2017-09-01
To assess whether low voltage chest computed tomography (CT) can be used to successfully diagnose disease in patients with asbestos exposure. Fifty-six former employees of the shipbuilding industry, who were candidates to receive a standard-dose chest CT due to their occupational exposure to asbestos, underwent a routine CT. Immediately after this initial CT, they underwent a second acquisition using low-dose chest CT parameters, based on a low potential (80 kV) and limited tube current. The findings of the two CT protocols were compared based on typical diseases associated with asbestos exposure. The kappa coefficient for each parameter and for an overall rating (grouping them based on mediastinal, pleural, and pulmonary findings) were calculated in order to test for correlations between the two protocols. A good correlation between routine and low-dose CT was demonstrated for most parameters with a mean radiation dose reduction of up to 83% of the effective dose based on the dose-length product between protocols. Low-dose chest CT, based on a limited tube potential, is useful for patients with an asbestos exposure background. Low-dose chest CT can be successfully used to minimise the radiation dose received by patients, as this protocol produced an estimated mean effective dose similar to that of an abdominal or pelvis plain film. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-27
... 11-153] Basic Service Tier Encryption Compatibility Between Cable Systems and Consumer Electronics... substantially affect compatibility between cable service and consumer electronics equipment for most subscribers... problems between cable service and consumer electronics equipment were limiting and/or precluding the...
NASA Astrophysics Data System (ADS)
Adibzadeh, F.; Verhaart, R. F.; Verduijn, G. M.; Fortunati, V.; Rijnen, Z.; Franckena, M.; van Rhoon, G. C.; Paulides, M. M.
2015-02-01
To provide an adequate level of protection for humans from exposure to radio-frequency (RF) electromagnetic fields (EMF) and to assure that any adverse health effects are avoided. The basic restrictions in terms of the specific energy absorption rate (SAR) were prescribed by IEEE and ICNIRP. An example of a therapeutic application of non-ionizing EMF is hyperthermia (HT), in which intense RF energy is focused at a target region. Deep HT in the head and neck (H&N) region involves inducing energy at 434 MHz for 60 min on target. Still, stray exposure of the brain is considerable, but to date only very limited side-effects were observed. The objective of this study is to investigate the stringency of the current basic restrictions by relating the induced EM dose in the brain of patients treated with deep head and neck (H&N) HT to the scored acute health effects. We performed a simulation study to calculate the induced peak 10 g spatial-averaged SAR (psSAR10g) in the brains of 16 selected H&N patients who received the highest SAR exposure in the brain, i.e. who had the minimum brain-target distance and received high forwarded power during treatment. The results show that the maximum induced SAR in the brain of the patients can exceed the current basic restrictions (IEEE and ICNIRP) on psSAR10g for occupational environments by 14 times. Even considering the high local SAR in the brain, evaluation of acute effects by the common toxicity criteria (CTC) scores revealed no indication of a serious acute neurological effect. In addition, this study provides pioneering quantitative human data on the association between maximum brain SAR level and acute adverse effects when brains are exposed to prolonged RF EMF.
A GPU-accelerated and Monte Carlo-based intensity modulated proton therapy optimization system.
Ma, Jiasen; Beltran, Chris; Seum Wan Chan Tseung, Hok; Herman, Michael G
2014-12-01
Conventional spot scanning intensity modulated proton therapy (IMPT) treatment planning systems (TPSs) optimize proton spot weights based on analytical dose calculations. These analytical dose calculations have been shown to have severe limitations in heterogeneous materials. Monte Carlo (MC) methods do not have these limitations; however, MC-based systems have been of limited clinical use due to the large number of beam spots in IMPT and the extremely long calculation time of traditional MC techniques. In this work, the authors present a clinically applicable IMPT TPS that utilizes a very fast MC calculation. An in-house graphics processing unit (GPU)-based MC dose calculation engine was employed to generate the dose influence map for each proton spot. With the MC generated influence map, a modified least-squares optimization method was used to achieve the desired dose volume histograms (DVHs). The intrinsic CT image resolution was adopted for voxelization in simulation and optimization to preserve spatial resolution. The optimizations were computed on a multi-GPU framework to mitigate the memory limitation issues for the large dose influence maps that resulted from maintaining the intrinsic CT resolution. The effects of tail cutoff and starting condition were studied and minimized in this work. For relatively large and complex three-field head and neck cases, i.e., >100,000 spots with a target volume of ∼ 1000 cm(3) and multiple surrounding critical structures, the optimization together with the initial MC dose influence map calculation was done in a clinically viable time frame (less than 30 min) on a GPU cluster consisting of 24 Nvidia GeForce GTX Titan cards. The in-house MC TPS plans were comparable to a commercial TPS plans based on DVH comparisons. A MC-based treatment planning system was developed. The treatment planning can be performed in a clinically viable time frame on a hardware system costing around 45,000 dollars. The fast calculation and optimization make the system easily expandable to robust and multicriteria optimization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Yong Sang; Lee, Jae-Lyun; Park, Jin Hong
Purpose: To perform a Phase I study of preoperative chemoradiation (CRT) with S-1, a novel oral fluoropyrimidine, plus oxaliplatin in patients with locally advanced rectal cancer, to determine the maximum tolerated dose and the recommended dose. Methods and Materials: Radiotherapy was delivered to a total of 45 Gy in 25 fractions and followed by a coned-down boost of 5.4 Gy in 3 fractions. Concurrent chemotherapy consisted of a fixed dose of oxaliplatin (50 mg/m{sup 2}/week) on Days 1, 8, 22, and 29 and escalated doses of S-1 on Days 1-14 and 22-35. The initial dose of S-1 was 50 mg/m{supmore » 2}/day, gradually increasing to 60, 70, and 80 mg/m{sup 2}/day. Surgery was performed within 6 {+-} 2 weeks. Results: Twelve patients were enrolled and tolerated up to Dose Level 4 (3 patients at each dose level) without dose-limiting toxicity. An additional 3 patients were enrolled at Dose Level 4, with 1 experiencing a dose-limiting toxicity of Grade 3 diarrhea. Although maximum tolerated dose was not attained, Dose Level 4 (S-1 80 mg/m{sup 2}/day) was chosen as the recommended dose for further Phase II studies. No Grade 4 toxicity was observed, and Grade 3 toxicities of leukopenia and diarrhea occurred in the same patient (1 of 15, 6.7%). Pathologic complete responses were observed in 2 of 15 patients (13.3%). Conclusions: The recommended dose of S-1 was determined to be 80 mg/m{sup 2}/day when combined with oxaliplatin in preoperative CRT, and a Phase II trial is now ongoing.« less
BENCHMARK DOSE TECHNICAL GUIDANCE DOCUMENT ...
The purpose of this document is to provide guidance for the Agency on the application of the benchmark dose approach in determining the point of departure (POD) for health effects data, whether a linear or nonlinear low dose extrapolation is used. The guidance includes discussion on computation of benchmark doses and benchmark concentrations (BMDs and BMCs) and their lower confidence limits, data requirements, dose-response analysis, and reporting requirements. This guidance is based on today's knowledge and understanding, and on experience gained in using this approach.
The estimation of galactic cosmic ray penetration and dose rates
NASA Technical Reports Server (NTRS)
Burrell, M. O.; Wright, J. J.
1972-01-01
This study is concerned with approximation methods that can be readily applied to estimate the absorbed dose rate from cosmic rays in rads - tissue or rems inside simple geometries of aluminum. The present work is limited to finding the dose rate at the center of spherical shells or behind plane slabs. The dose rate is calculated at tissue-point detectors or for thin layers of tissue. This study considers cosmic-rays dose rates for both free-space and earth-orbiting missions.
Cumulative total effective whole-body radiation dose in critically ill patients.
Rohner, Deborah J; Bennett, Suzanne; Samaratunga, Chandrasiri; Jewell, Elizabeth S; Smith, Jeffrey P; Gaskill-Shipley, Mary; Lisco, Steven J
2013-11-01
Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.
Furman, Wayne L; Crews, Kristine R; Billups, Catherine; Wu, Jianrong; Gajjar, Amar J; Daw, Najat C; Patrick, Christian C; Rodriguez-Galindo, Carlos; Stewart, Clinton F; Dome, Jeffrey S; Panetta, John C; Houghton, Peter J; Santana, Victor M
2006-02-01
Irinotecan is active against a variety of malignancies; however, severe diarrhea limits its usefulness. In our phase I study, the intravenous formulation of irinotecan was administered orally daily for 5 days for 2 consecutive weeks (repeated every 21 days) to children with refractory solid tumors. Our objectives were to determine the maximum-tolerated dose (MTD), dose-limiting toxicity, and pharmacokinetics of oral irinotecan and to evaluate whether coadministration of cefixime (8 mg/kg/d beginning 5 days before irinotecan and continuing throughout the course) ameliorates irinotecan-induced diarrhea. In separate cohorts, irinotecan doses were escalated from 15 to 45 mg/m2/d without cefixime and then from 45 to 60 and 75 mg/m2/d with cefixime. Without cefixime, diarrhea was dose limiting at irinotecan 45 mg/m2/d. Myelotoxicity was not significant at any dose. The MTD was 40 mg/m2/d without cefixime but 60 mg/m2/d with cefixime. Systemic exposure to SN-38 at the MTD was significantly higher with cefixime than without cefixime (mean SN-38 area under the curve: 19.5 ng x h/mL; standard deviation [SD], 6.8 ng x h/mL v 10.4 ng x h/mL; SD, 4.3 ng x h/mL, respectively; P = .030). Cefixime administered with oral irinotecan is well tolerated in children and allows greater dose escalation of irinotecan. Because diarrhea is a major adverse effect of both intravenous and oral irinotecan, further evaluation of the use of cefixime to ameliorate this adverse effect is warranted.
Three Concepts or One? Students' Understanding of Basic Limit Concepts
ERIC Educational Resources Information Center
Fernández-Plaza, José Antonio; Simpson, Adrian
2016-01-01
In many mathematics curricula, the notion of limit is introduced three times: the limit of a sequence, the limit of a function at a point and the limit of a function at infinity. Despite the use of very similar symbols, few connections between these notions are made explicitly and few papers in the large literature on student understanding of…
An efficient inverse radiotherapy planning method for VMAT using quadratic programming optimization.
Hoegele, W; Loeschel, R; Merkle, N; Zygmanski, P
2012-01-01
The purpose of this study is to investigate the feasibility of an inverse planning optimization approach for the Volumetric Modulated Arc Therapy (VMAT) based on quadratic programming and the projection method. The performance of this method is evaluated against a reference commercial planning system (eclipse(TM) for rapidarc(TM)) for clinically relevant cases. The inverse problem is posed in terms of a linear combination of basis functions representing arclet dose contributions and their respective linear coefficients as degrees of freedom. MLC motion is decomposed into basic motion patterns in an intuitive manner leading to a system of equations with a relatively small number of equations and unknowns. These equations are solved using quadratic programming under certain limiting physical conditions for the solution, such as the avoidance of negative dose during optimization and Monitor Unit reduction. The modeling by the projection method assures a unique treatment plan with beneficial properties, such as the explicit relation between organ weightings and the final dose distribution. Clinical cases studied include prostate and spine treatments. The optimized plans are evaluated by comparing isodose lines, DVH profiles for target and normal organs, and Monitor Units to those obtained by the clinical treatment planning system eclipse(TM). The resulting dose distributions for a prostate (with rectum and bladder as organs at risk), and for a spine case (with kidneys, liver, lung and heart as organs at risk) are presented. Overall, the results indicate that similar plan qualities for quadratic programming (QP) and rapidarc(TM) could be achieved at significantly more efficient computational and planning effort using QP. Additionally, results for the quasimodo phantom [Bohsung et al., "IMRT treatment planning: A comparative inter-system and inter-centre planning exercise of the estro quasimodo group," Radiother. Oncol. 76(3), 354-361 (2005)] are presented as an example for an extreme concave case. Quadratic programming is an alternative approach for inverse planning which generates clinically satisfying plans in comparison to the clinical system and constitutes an efficient optimization process characterized by uniqueness and reproducibility of the solution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Unkelbach, J; Perko, Z; Wolfgang, J
Purpose: Stereotactic body radiotherapy (SBRT) has become an established treatment option for liver cancer. For patients with large tumors, the prescription dose is often limited by constraints on the mean liver dose, leading to tumor recurrence. In this work, we demonstrate that spatiotemporal fractionation schemes, ie delivering distinct dose distributions in different fractions, may allow for a 10% increase in biologically effective dose (BED) in the tumor compared to current practice where each fraction delivers the same dose distribution. Methods: We consider rotation therapy delivered with x-ray beams. Treatment plan optimization is performed using objective functions evaluated for the cumulativemore » BED delivered at the end of treatment. This allows for simultaneously optimizing multiple distinct treatment plans for different fractions. Results: The treatment that optimally exploits fractionation effects is designed such that each fraction delivers a similar dose bath to the uninvolved liver while delivering high single fraction doses to complementary parts of the target volume. Thereby, partial hypofractionation in the tumor is achieved along with near uniform fractionation in the surrounding liver - leading to an improvement in the therapeutic ratio. The benefit of such spatiotemporal fractionation schemes depends on tumor geometry and location as well as the number of fractions. For 5-fraction treatments (allowing for 5 distinct dose distributions) an improvement in the order of 10% is observed. Conclusion: Delivering distinct dose distributions in different fractions, purely motivated by fractionation effects rather than geometric changes, may improve the therapeutic ratio. For treatment sites where the prescriptions dose is limited by mean dose constraints in the surrounding organ, such as liver cancer, this approach may facilitate biological dose escalation and improved cure rates.« less
Dose rate constants for the quantity Hp(3) for frequently used radionuclides in nuclear medicine.
Szermerski, Bastian; Bruchmann, Iris; Behrens, Rolf; Geworski, Lilli
2016-12-01
According to recent studies, the human eye lens is more sensitive to ionising radiation than previously assumed. Therefore, the dose limit for personnel occupationally exposed to ionising radiation will be lowered from currently 150 mSv to 20 mSv per year. Currently, no data base for a reliable estimation of the dose to the lens of the eye is available for nuclear medicine. Furthermore, the dose is usually not monitored. The aim of this work was to determine dose rate constants for the quantity H p (3), which is supposed to estimate the dose to the lens of the eye. For this, H p (3)-dosemeters were fixed to an Alderson Phantom at different positions. The dosemeters were exposed to radiation from nuclides typically used in nuclear medicine in their geometries analog to their application in nuclear medicine, e.g. syringe or vial. The results show that the handling of high-energy beta (i.e. electron or positron) emitters may lead to a relevant dose to the lens of the eye. For low-energy beta emitters and gamma emitters, an exceeding of the lowered dose limit seems to be unlikely. Copyright © 2015. Published by Elsevier GmbH.
Plasma myelin basic protein assay using Gilford enzyme immunoassay cuvettes.
Groome, N P
1981-10-01
The assay of myelin basic protein in body fluids has potential clinical importance as a routine indicator of demyelination. Preliminary details of a competitive enzyme immunoassay for this protein have previously been published by the author (Groome, N. P. (1980) J. Neurochem. 35, 1409-1417). The present paper now describes the adaptation of this assay for use on human plasma and various aspects of routine data processing. A commercially available cuvette system was found to have advantages over microtitre plates but required a permuted arrangement of sample replicates for consistent results. For dose interpolation, the standard curve could be fitted to a three parameter non-linear equation by regression analysis or linearised by the logit/log transformation.
Alpha 97: Basic Education and Institutional Environments.
ERIC Educational Resources Information Center
Hautecoeur, Jean-Paul, Ed.
This document was published by Alpha, a research program specializing in alternative, experimental approaches to adult basic education. It is an attempt to widen the field and examine the relationship between the micro and macro levels, between the diversity of different practices and the major policy orientations that foster or limit this…
42 CFR 424.80 - Prohibition of reassignment of claims by suppliers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM CONDITIONS FOR MEDICARE PAYMENT Limitations on Assignment and Reassignment of Claims § 424.80 Prohibition of reassignment of claims by suppliers. (a) Basic... the basic rule—(1) Payment to employer. Medicare may pay the supplier's employer if the supplier is...
A procedure to determine the planar integral spot dose values of proton pencil beam spots
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anand, Aman; Sahoo, Narayan; Zhu, X. Ronald
2012-02-15
Purpose: Planar integral spot dose (PISD) of proton pencil beam spots (PPBSs) is a required input parameter for beam modeling in some treatment planning systems used in proton therapy clinics. The measurement of PISD by using commercially available large area ionization chambers, like the PTW Bragg peak chamber (BPC), can have large uncertainties due to the size limitation of these chambers. This paper reports the results of our study of a novel method to determine PISD values from the measured lateral dose profiles and peak dose of the PPBS. Methods: The PISDs of 72.5, 89.6, 146.9, 181.1, and 221.8 MeVmore » energy PPBSs were determined by area integration of their planar dose distributions at different depths in water. The lateral relative dose profiles of the PPBSs at selected depths were measured by using small volume ion chambers and were investigated for their angular anisotropies using Kodak XV films. The peak spot dose along the beam's central axis (D{sub 0}) was determined by placing a small volume ion chamber at the center of a broad field created by the superposition of spots at different locations. This method allows eliminating positioning uncertainties and the detector size effect that could occur when measuring it in single PPBS. The PISD was then calculated by integrating the measured lateral relative dose profiles for two different upper limits of integration and then multiplying it with corresponding D{sub 0}. The first limit of integration was set to radius of the BPC, namely 4.08 cm, giving PISD{sub RBPC}. The second limit was set to a value of the radial distance where the profile dose falls below 0.1% of the peak giving the PISD{sub full}. The calculated values of PISD{sub RBPC} obtained from area integration method were compared with the BPC measured values. Long tail dose correction factors (LTDCFs) were determined from the ratio of PISD{sub full}/PISD{sub RBPC} at different depths for PPBSs of different energies. Results: The spot profiles were found to have angular anisotropy. This anisotropy in PPBS dose distribution could be accounted in a reasonable approximate manner by taking the average of PISD values obtained using the in-line and cross-line profiles. The PISD{sub RBPC} values fall within 3.5% of those measured by BPC. Due to inherent dosimetry challenges associated with PPBS dosimetry, which can lead to large experimental uncertainties, such an agreement is considered to be satisfactory for validation purposes. The PISD{sub full} values show differences ranging from 1 to 11% from BPC measured values, which are mainly due to the size limitation of the BPC to account for the dose in the long tail regions of the spots extending beyond its 4.08 cm radius. The dose in long tail regions occur both for high energy beams such as 221.8 MeV PPBS due to the contributions of nuclear interactions products in the medium, and for low energy PPBS because of their larger spot sizes. The calculated LTDCF values agree within 1% with those determined by the Monte Carlo (MC) simulations. Conclusions: The area integration method to compute the PISD from PPBS lateral dose profiles is found to be useful both to determine the correction factors for the values measured by the BPC and to validate the results from MC simulations.« less
21 CFR 361.1 - Radioactive drugs for certain research uses.
Code of Federal Regulations, 2014 CFR
2014-04-01
... following: Whole body, active blood-forming organs, lens of the eye, and gonads: Rems Single dose 3 Annual... body, active blood-forming organs, lens of the eye, gonads, and other organ doses from the administered... set forth in paragraph (d) of this section, that: (i) The pharmacological dose is within the limits...
21 CFR 361.1 - Radioactive drugs for certain research uses.
Code of Federal Regulations, 2013 CFR
2013-04-01
... following: Whole body, active blood-forming organs, lens of the eye, and gonads: Rems Single dose 3 Annual... body, active blood-forming organs, lens of the eye, gonads, and other organ doses from the administered... set forth in paragraph (d) of this section, that: (i) The pharmacological dose is within the limits...
21 CFR 361.1 - Radioactive drugs for certain research uses.
Code of Federal Regulations, 2012 CFR
2012-04-01
... following: Whole body, active blood-forming organs, lens of the eye, and gonads: Rems Single dose 3 Annual... body, active blood-forming organs, lens of the eye, gonads, and other organ doses from the administered... set forth in paragraph (d) of this section, that: (i) The pharmacological dose is within the limits...
10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Compliance with requirements for summation of external and internal doses. 20.1202 Section 20.1202 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1202 Compliance with requirements for summation of...
10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Compliance with requirements for summation of external and internal doses. 20.1202 Section 20.1202 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1202 Compliance with requirements for summation of...
10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Compliance with requirements for summation of external and internal doses. 20.1202 Section 20.1202 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1202 Compliance with requirements for summation of...
10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Compliance with requirements for summation of external and internal doses. 20.1202 Section 20.1202 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1202 Compliance with requirements for summation of...
10 CFR 20.1202 - Compliance with requirements for summation of external and internal doses.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Compliance with requirements for summation of external and internal doses. 20.1202 Section 20.1202 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1202 Compliance with requirements for summation of...
Subacute toxicity of the mycotoxin cyclopiazonic acid.
van Rensburg, S J
1984-12-01
Cyclopiazonic acid (CA) is known to contaminate processed foods, maize and peanuts. Since previously available toxicity data were limited to the effects of single doses, Wistar-derived rats were given weekly doses of 0, 12 or 21 mg CA/kg body weight in 1 N-sodium bicarbonate, using a dosage volume of 2.5 ml/kg body weight, and subgroups of eight were killed 1 wk after doses 2, 5, 9 and 14. Males on the highest dose level showed mild growth retardation initially and 25% died suddenly during wk 4. No abnormal signs were observed in the surviving males or in any of the females throughout the 15 wk of the experiment. CA induced mild cellular degenerative changes in the myocardium and in several other organs where ballooning of nuclei, especially in ductal epithelia, was also characteristic. The changes were only weakly related to dose level, sex and the number of doses given. The findings suggest that CA is probably a metabolic inhibitor requiring considerable concentrations to exert toxicity. The limited data currently available do not elicit concern in terms of human risk or warrant any particular control procedures.
Li, Zijian; Jennings, Aaron A.
2017-01-01
Worldwide jurisdictions are making efforts to regulate pesticide standard values in residential soil, drinking water, air, and agricultural commodity to lower the risk of pesticide impacts on human health. Because human may exposure to pesticides from many ways, such as ingestion, inhalation, and dermal contact, it is important to examine pesticide standards by considering all major exposure pathways. Analysis of implied maximum dose limits for commonly historical and current used pesticides was adopted in this study to examine whether worldwide pesticide standard values are enough to prevent human health impact or not. Studies show that only U.S. has regulated pesticides standard in the air. Only 4% of the total number of implied maximum dose limits is based on three major exposures. For Chlorpyrifos, at least 77.5% of the total implied maximum dose limits are above the acceptable daily intake. It also shows that most jurisdictions haven't provided pesticide standards in all major exposures yet, and some of the standards are not good enough to protect human health. PMID:29546224
Lee, Byung Kook; Kim, Mu Jin; Jeung, Kyung Woon; Choi, Sung Soo; Park, Sang Wook; Yun, Seong Woo; Lee, Sung Min; Lee, Dong Hun; Min, Yong Il
2016-06-01
Ischemic contracture compromises the hemodynamic effectiveness of cardiopulmonary resuscitation (CPR) and resuscitability from cardiac arrest. In a pig model of cardiac arrest, 2,3-butanedione monoxime (BDM) attenuated ischemic contracture. We investigated the effects of different doses of BDM to determine whether increasing the dose of BDM could improve the hemodynamic effectiveness of CPR further, thus ultimately improving resuscitability. After 16minutes of untreated ventricular fibrillation and 8minutes of basic life support, 36 pigs were divided randomly into 3 groups that received 50mg/kg (low-dose group) of BDM, 100mg/kg (high-dose group) of BDM, or an equivalent volume of saline (control group) during advanced cardiovascular life support. During advanced cardiovascular life support, the control group showed an increase in left ventricular (LV) wall thickness and a decrease in LV chamber area. In contrast, the BDM-treated groups showed a decrease in the LV wall thickness and an increase in the LV chamber area in a dose-dependent fashion. Mixed-model analyses of the LV wall thickness and LV chamber area revealed significant group effects and group-time interactions. Central venous oxygen saturation at 3minutes after the drug administration was 21.6% (18.4-31.9), 39.2% (28.8-53.7), and 54.0% (47.5-69.4) in the control, low-dose, and high-dose groups, respectively (P<.001). Sustained restoration of spontaneous circulation was attained in 7 (58.3%), 10 (83.3%), and 12 animals (100%) in the control, low-dose, and high-dose groups, respectively (P=.046). 2,3-Butanedione monoxime administered during CPR attenuated ischemic contracture and improved the resuscitability in a dose-dependent fashion. Copyright © 2016 Elsevier Inc. All rights reserved.
Sakurai, T; Kawamata, R; Kozai, Y; Kaku, Y; Nakamura, K; Saito, M; Wakao, H; Kashima, I
2010-05-01
The aim of the study was to clarify the change in image quality upon X-ray dose reduction and to re-analyse the possibility of X-ray dose reduction in photostimulable phosphor luminescence (PSPL) X-ray imaging systems. In addition, the study attempted to verify the usefulness of multiobjective frequency processing (MFP) and flexible noise control (FNC) for X-ray dose reduction. Three PSPL X-ray imaging systems were used in this study. Modulation transfer function (MTF), noise equivalent number of quanta (NEQ) and detective quantum efficiency (DQE) were evaluated to compare the basic physical performance of each system. Subjective visual evaluation of diagnostic ability for normal anatomical structures was performed. The NEQ, DQE and diagnostic ability were evaluated at base X-ray dose, and 1/3, 1/10 and 1/20 of the base X-ray dose. The MTF of the systems did not differ significantly. The NEQ and DQE did not necessarily depend on the pixel size of the system. The images from all three systems had a higher diagnostic utility compared with conventional film images at the base and 1/3 X-ray doses. The subjective image quality was better at the base X-ray dose than at 1/3 of the base dose in all systems. The MFP and FNC-processed images had a higher diagnostic utility than the images without MFP and FNC. The use of PSPL imaging systems may allow a reduction in the X-ray dose to one-third of that required for conventional film. It is suggested that MFP and FNC are useful for radiation dose reduction.
Abourbih, Daniel Asher; Gosselin, Sophie; Villeneuve, Eric; Kazim, Sara
2016-01-01
Acetaminophen (APAP) elixir is a widely used pediatric antipyretic medication. It has been shown that up to 30% of febrile children presenting to a large urban pediatric emergency department received inadequate APAP dosages at home with errors primarily due to age-based dosing. Parental education material in the form of weight-based dosing guides has been proposed; however, validation of current recommended APAP dosages using pharmacokinetic models is needed. This study used a mathematical model of APAP absorption to predict plasma concentrations and to compare them with the range required to reach and achieve antipyresis (10-20 μg/mL). A common APAP preparation (Children's Tylenol Elixir) was tested (children aged 2-3 years, 10.9-15.9 kg). The manufacturer's suggested dose of 160 mg was compared with the standard 10 to 15 mg/kg dose range. The model predicts a peak plasma concentration between 6.38 and 8.55 μg/mL for 10 mg/kg dose and 9.57 and 12.8 μg/mL for 15 mg/kg dose. The manufacturer's suggested dose of 160 mg was tested across the limits of the weight range (10.9-15.9 kg). A peak plasma concentration between 9.36 and 12.6 μg/mL was found for the lower weight limit (10.9 kg child) and 6.42 to 8.61 μg/mL for the upper weight limit (15.9 kg child). With the use of this model, the 10 mg/kg dose does not reach the plasma concentration value for antipyresis (10-20 μg/mL), whereas 15 mg/kg is adequate only if assuming a greater absorption constant. The 160 mg dose is effective only for children weighing 10.9 kg. Individual differences in drug bioavailability, volume of distribution, and absorption/elimination constants undoubtedly exist, and future studies directly measuring plasma APAP concentration and pharmacokinetics are needed. However, these results indicate that dosages for APAP in children should be weight based and manufacturers should review their dosing recommendations.
Imaging study of using radiopharmaceuticals labeled with cyclotron-produced 99mTc.
Hou, X; Tanguay, J; Vuckovic, M; Buckley, K; Schaffer, P; Bénard, F; Ruth, T J; Celler, A
2016-12-07
Cyclotron-produced 99m Tc (CPTc) has been recognized as an attractive and practical substitution of reactor/generator based 99m Tc. However, the small amount of 92-98 Mo in the irradiation of enriched 100 Mo could lead to the production of other radioactive technetium isotopes (Tc-impurities) which cannot be chemically separated. Thus, these impurities could contribute to patient dose and affect image quality. The potential radiation dose caused by these Tc-impurities produced using different targets, irradiation conditions, and corresponding to different injection times have been investigated, leading us to create dose-based limits of these parameters for producing clinically acceptable CPTc. However, image quality has been not considered. The aim of the present work is to provide a comprehensive and quantitative analysis of image quality for CPTc. The impact of Tc-impurities in CPTc on image resolution, background noise, and contrast is investigated by performing both Monte-Carlo simulations and phantom experiments. Various targets, irradiation, and acquisition conditions are employed for investigating the image-based limits of CPTc production parameters. Additionally, the relationship between patient dose and image quality of CPTc samples is studied. Only those samples which meet both dose- and image-based limits should be accepted in future clinical studies.
Imaging study of using radiopharmaceuticals labeled with cyclotron-produced 99mTc
NASA Astrophysics Data System (ADS)
Hou, X.; Tanguay, J.; Vuckovic, M.; Buckley, K.; Schaffer, P.; Bénard, F.; Ruth, T. J.; Celler, A.
2016-12-01
Cyclotron-produced 99mTc (CPTc) has been recognized as an attractive and practical substitution of reactor/generator based 99mTc. However, the small amount of 92-98Mo in the irradiation of enriched 100Mo could lead to the production of other radioactive technetium isotopes (Tc-impurities) which cannot be chemically separated. Thus, these impurities could contribute to patient dose and affect image quality. The potential radiation dose caused by these Tc-impurities produced using different targets, irradiation conditions, and corresponding to different injection times have been investigated, leading us to create dose-based limits of these parameters for producing clinically acceptable CPTc. However, image quality has been not considered. The aim of the present work is to provide a comprehensive and quantitative analysis of image quality for CPTc. The impact of Tc-impurities in CPTc on image resolution, background noise, and contrast is investigated by performing both Monte-Carlo simulations and phantom experiments. Various targets, irradiation, and acquisition conditions are employed for investigating the image-based limits of CPTc production parameters. Additionally, the relationship between patient dose and image quality of CPTc samples is studied. Only those samples which meet both dose- and image-based limits should be accepted in future clinical studies.
Requirements for pharmacokinetic evaluation of antibiotics in phase I studies.
Bergan, T
1986-01-01
Initial pharmacokinetic studies usually include healthy volunteers to minimize variation generated by diseases. Ethical aspects of initial studies are paramount. The guidelines of the Helsinki Declaration should be followed or even extended. Thorough toxicologic screening in animals is a prerequisite. The use of radioisotopes for pharmacokinetic studies should be limited. The basic design of studies includes cross-over administration of intravenous and oral doses of several sizes. Bioavailability, total area under the serum concentration curve, serum half-life, amount eliminated in urine as active drug, and metabolism are the most important data. The fate of the parent compound and of its possible metabolites in both healthy persons and ill individuals (including those with renal or hepatic dysfunction) should be monitored. Diet may have consequences with regard to recommended dosage schedules. When possible, tissue penetration of antibiotics should be assessed, preferably through the analysis of peripheral human lymph and of suction-blister and peritoneal fluids. Theoretical dosage schedules based on pharmacokinetic assessments in healthy persons should be tested in patients with infectious disease, particularly in those with reduced renal and/or hepatic function.
Basis for standards: ICRP activities.
Vano, E
2015-07-01
The purpose of this chapter is to describe work achieved recently by the International Commission on Radiological Protection (ICRP) and especially by Committee 3 (Protection in Medicine) and its use for standards. In March 1960, the Board of Governors of the International Atomic Energy Agency approved the Agency's 'Health and Safety Measures', stating that the Agency's 'Basic Safety Standards' (BSS) would be based, to the extent possible, on the recommendations of the ICRP. In a similar way, the Council of the European Union took into account the new recommendations of the ICRP when adopting the new Directive 2013/59/EURATOM that laid down BSS for protection against the dangers arising from exposure to ionising radiation. The new limit for the lens of the eyes for occupational exposures has been incorporated into these international standards and several articles dealing with medical exposures: justification, optimisation, recording patient doses, the use of diagnostic reference levels, training, accidental and unintended exposures, etc. have also been included in agreement with the ICRP recommendations. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Toxicity assessment of Chlorella vulgaris and Chlorella protothecoides following exposure to Pb(II).
Zhang, Wei; Xiong, Bang; Chen, Lin; Lin, Kuangfei; Cui, Xinhong; Bi, Huasong; Guo, Meijin; Wang, Weiliang
2013-07-01
The short- and long-term toxic effects of Pb(II) exposure on Chlorella vulgaris (C. vulgaris) and Chlorella protothecoides (C. protothecoides) were not well understood. The lab study was performed to observe the Pb(II) exposure induced changes. Results of the observations show: (1) higher level of Pb(II) (50 or 80mgL(-1)) could significantly inhibit the growth and chlorophyll a synthesis of both algae in almost all the treatments and dose-response relationships could be clearly observed, (2) the range of EC50 values (24-120h, 67.73-172.45mgL(-1)) indicated that Pb(II) had a relatively limited short-term toxicity to the two algae, while long-term tests (7-28d, 50.41-63.91mgL(-1)) displayed higher toxicity and (3) SOD and CAT activities of both algae after exposed to medium level of Pb(II) were significantly promoted, and their response might be more susceptible in short-term exposure. This research provides a basic understanding of Pb(II) toxicity to aquatic organisms. Copyright © 2013 Elsevier B.V. All rights reserved.
Radiation dose response of N channel MOSFET submitted to filtered X-ray photon beam
NASA Astrophysics Data System (ADS)
Gonçalves Filho, Luiz C.; Monte, David S.; Barros, Fabio R.; Santos, Luiz A. P.
2018-01-01
MOSFET can operate as a radiation detector mainly in high-energy photon beams, which are normally used in cancer treatments. In general, such an electronic device can work as a dosimeter from threshold voltage shift measurements. The purpose of this article is to show a new way for measuring the dose-response of MOSFETs when they are under X-ray beams generated from 100kV potential range, which is normally used in diagnostic radiology. Basically, the method consists of measuring the MOSFET drain current as a function of the radiation dose. For this the type of device, it has to be biased with a high value resistor aiming to see a substantial change in the drain current after it has been irradiated with an amount of radiation dose. Two types of N channel device were used in the experiment: a signal transistor and a power transistor. The delivered dose to the device was varied and the electrical curves were plotted. Also, a sensitivity analysis of the power MOSFET response was made, by varying the tube potential of about 20%. The results show that both types of devices have responses very similar, the shift in the electrical curve is proportional to the radiation dose. Unlike the power MOSFET, the signal transistor does not provide a linear function between the dose rate and its drain current. We also have observed that the variation in the tube potential of the X-ray equipment produces a very similar dose-response.