Sample records for battery testing procedures

  1. A Battery Certification Testbed for Small Satellite Missions

    NASA Technical Reports Server (NTRS)

    Cameron, Zachary; Kulkarni, Chetan S.; Luna, Ali Guarneros; Goebel, Kai; Poll, Scott

    2015-01-01

    A battery pack consisting of standard cylindrical 18650 lithium-ion cells has been chosen for small satellite missions based on previous flight heritage and compliance with NASA battery safety requirements. However, for batteries that transit through the International Space Station (ISS), additional certification tests are required for individual cells as well as the battery packs. In this manuscript, we discuss the development of generalized testbeds for testing and certifying different types of batteries critical to small satellite missions. Test procedures developed and executed for this certification effort include: a detailed physical inspection before and after experiments; electrical cycling characterization at the cell and pack levels; battery-pack overcharge, over-discharge, external short testing; battery-pack vacuum leak and vibration testing. The overall goals of these certification procedures are to conform to requirements set forth by the agency and identify unique safety hazards. The testbeds, procedures, and experimental results are discussed for batteries chosen for small satellite missions to be launched from the ISS.

  2. Battery Test Manual For Plug-In Hybrid Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeffrey R. Belt

    2010-09-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the proceduresmore » and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.« less

  3. Battery Test Manual For Plug-In Hybrid Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeffrey R. Belt

    2010-12-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the proceduresmore » and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.« less

  4. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT XIII, BATTERY SERVICE AND TESTING PROCEDURES--PART II.

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO FAMILIARIZE THE TRAINEE WITH PROCEDURES FOR SERVICING LEAD-ACID STORAGE BATTERIES USED ON DIESEL POWERED EQUIPMENT. TOPICS ARE (1) ELECTROLYTE AND SPECIFIC GRAVITY, (2) BATTERY CHARGING, (3) STORAGE BATTERY TYPES AND DESIGN, (4) BATTERY CAPACITY RATINGS, (5) BATTERY INSTALLATION, SERVICING, AND…

  5. 40 CFR 63.309 - Performance tests and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Standards for Coke Oven Batteries § 63.309 Performance tests and procedures. (a) Except as otherwise... coke oven battery, the results of which shall be used in accordance with procedures specified in this subpart to determine compliance with each of the applicable visible emission limitations for coke oven...

  6. 40 CFR 63.309 - Performance tests and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Standards for Coke Oven Batteries § 63.309 Performance tests and procedures. (a) Except as otherwise... coke oven battery, the results of which shall be used in accordance with procedures specified in this subpart to determine compliance with each of the applicable visible emission limitations for coke oven...

  7. 40 CFR 63.309 - Performance tests and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Standards for Coke Oven Batteries § 63.309 Performance tests and procedures. (a) Except as otherwise... coke oven battery, the results of which shall be used in accordance with procedures specified in this subpart to determine compliance with each of the applicable visible emission limitations for coke oven...

  8. 40 CFR 63.309 - Performance tests and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Standards for Coke Oven Batteries § 63.309 Performance tests and procedures. (a) Except as otherwise... coke oven battery, the results of which shall be used in accordance with procedures specified in this subpart to determine compliance with each of the applicable visible emission limitations for coke oven...

  9. 40 CFR 63.309 - Performance tests and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Standards for Coke Oven Batteries § 63.309 Performance tests and procedures. (a) Except as otherwise... coke oven battery, the results of which shall be used in accordance with procedures specified in this subpart to determine compliance with each of the applicable visible emission limitations for coke oven...

  10. Performance features of 22-cell, 19Ah single pressure vessel nickel hydrogen battery

    NASA Technical Reports Server (NTRS)

    Rao, Gopalakrishna M.; Vaidyanathan, Hari

    1996-01-01

    Two 22-cells 19Ah Nickel-Hydrogen (Ni-H2) Single Pressure Vessel (SPV) Qual batteries, one each from EPI/Joplin and EPI/Butler, were designed and procured. The two batteries differ in the cell encapsulation technology, stack preload, and activation procedure. Both the Butler and Joplin batteries met the specified requirements when subjected to qualification testing and completed 2100 and 1300 LEO cycles respectively, with nominal performance. This paper discusses advantages, design features, testing procedures, and results of the two single pressure vessel Ni-H2 batteries.

  11. Separator Materials Used in Secondary Alkaline Batteries Characterized and Evaluated

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Nickel-cadmium (Ni/Cd) and nickel-hydrogen (Ni/H2) secondary alkaline batteries are vital to aerospace applications. Battery performance and cycle life are significantly affected by the type of separators used in those batteries. A team from NASA Lewis Research Center's Electrochemical Technology Branch developed standardized testing procedures to characterize and evaluate new and existing separator materials to improve performance and cycle life of secondary alkaline batteries. Battery separators must function as good electronic insulators and as efficient electrolyte reservoirs. At present, new types of organic and inorganic separator materials are being developed for Ni/Cd and Ni/H2 batteries. The separator material previously used in the NASA standard Ni/Cd was Pellon 2505, a 100-percent nylon-6 polymer that must be treated with zinc chloride (ZnCl2) to bond the fibers. Because of stricter Environmental Protection Agency regulation of ZnCl2 emissions, the battery community has been searching for new separators to replace Pellon 2505. As of today, two candidate separator materials have been identified; however, neither of the two materials have performed as well as Pellon 2505. The separator test procedures that were devised at Lewis are being implemented to expedite the search for new battery separators. The new test procedures, which are being carried out in the Separator Laboratory at Lewis, have been designed to guarantee accurate evaluations of the properties that are critical for sustaining proper battery operation. These properties include physical and chemical stability, chemical purity, gas permeability, electrolyte retention and distribution, uniformity, porosity, and area resistivity. A manual containing a detailed description of 12 separator test procedures has been drafted and will be used by the battery community to evaluate candidate separator materials for specific applications. These standardized procedures will allow for consistent, uniform, and reliable results that will ensure that separator materials have the desired properties for long life and good performance in secondary alkaline cells.

  12. 30 CFR 7.48 - Acid resistance test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.48 Acid resistance test. (a) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...

  13. 30 CFR 7.48 - Acid resistance test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.48 Acid resistance test. (a) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...

  14. Battery Test Manual For Electric Vehicles, Revision 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christophersen, Jon P.

    2015-06-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Electric Vehicles (EV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for EVs. However, it does share some methods described in the previously published battery test manual for plug-in hybrid electric vehicles. Due to the complexity of some of themore » procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Chul Bae of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).« less

  15. Test Procedures for Characterizing, Evaluating, and Managing Separator Materials used in Secondary Alkaline Batteries

    NASA Technical Reports Server (NTRS)

    Guasp, Edwin; Manzo, Michelle A.

    1997-01-01

    Secondary alkaline batteries, such as nickel-cadmium and silver-zinc, are commonly used for aerospace applications. The uniform evaluation and comparison of separator properties for these systems is dependent upon the measurement techniques. This manual presents a series of standard test procedures that can be used to evaluate, compare, and select separator materials for use in alkaline batteries. Detailed test procedures evaluating the following characteristics are included in this manual: physical measurements of thickness and area weight, dimensional stability measurements, electrolyte retention, resistivity, permeability as measured via bubble pressure, surface evaluation via SEM, chemical stability, and tensile strength.

  16. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    PubMed

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  17. Semi-Automated Full Battery.

    ERIC Educational Resources Information Center

    Vincent, Ken R.

    1980-01-01

    Presents the format for the development of interpretive statements covering an entire test battery content on both objective tests and projective instruments. This procedure, the semiautomated full battery, can lessen significantly the time and much of the repetition entailed in psychological report writing. (Author)

  18. U.S. Department of Energy Vehicle Technologies Program: Battery Test Manual For Plug-In Hybrid Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christophersen, Jon P.

    2014-09-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of somemore » of the procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Renata M. Arsenault of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).« less

  19. Operationally Responsive Space Standard Bus Battery Thermal Balance Testing and Heat Dissipation Analysis

    NASA Technical Reports Server (NTRS)

    Marley, Mike

    2008-01-01

    The focus of this paper will be on the thermal balance testing for the Operationally Responsive Space Standard Bus Battery. The Standard Bus thermal design required that the battery be isolated from the bus itself. This required the battery to have its own thermal control, including heaters and a radiator surface. Since the battery was not ready for testing during the overall bus thermal balance testing, a separate test was conducted to verify the thermal design for the battery. This paper will discuss in detail, the test set up, test procedure, and results from this test. Additionally this paper will consider the methods taken to determine the heat dissipation of the battery during charge and discharge. It seems that the heat dissipation for Lithium Ion batteries is relatively unknown and hard to quantify. The methods used during test and the post test analysis to estimate the heat dissipation of the battery will be discussed.

  20. 30 CFR 7.48 - Acid resistance test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... for the battery box and cover, only one sample need be prepared and tested. (2) Prepare a 30 percent... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...

  1. 30 CFR 7.48 - Acid resistance test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... for the battery box and cover, only one sample need be prepared and tested. (2) Prepare a 30 percent... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...

  2. 30 CFR 7.48 - Acid resistance test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... for the battery box and cover, only one sample need be prepared and tested. (2) Prepare a 30 percent... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...

  3. Development and field test of psychophysical tests for DWI arrest

    DOT National Transportation Integrated Search

    1981-03-01

    Administration and scoring procedures were standardized for a sobriety test battery consisting of the walk-and-turn test, the one leg stand test, and horizontal gaze nystagmus. The effectiveness of the standardized battery was then evaluated in the l...

  4. 40 CFR 63.7324 - What procedures must I use to demonstrate initial compliance with the opacity limits?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial Compliance Requirements § 63.7324... of 15 percent for a by-product coke oven battery on a normal coking cycle or 20 percent for a by-product coke oven battery on batterywide extended coking, follow the test methods and procedures in...

  5. 40 CFR 63.7324 - What procedures must I use to demonstrate initial compliance with the opacity limits?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial Compliance Requirements § 63.7324... of 15 percent for a by-product coke oven battery on a normal coking cycle or 20 percent for a by-product coke oven battery on batterywide extended coking, follow the test methods and procedures in...

  6. 40 CFR 63.7324 - What procedures must I use to demonstrate initial compliance with the opacity limits?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial Compliance Requirements § 63.7324... of 15 percent for a by-product coke oven battery on a normal coking cycle or 20 percent for a by-product coke oven battery on batterywide extended coking, follow the test methods and procedures in...

  7. 40 CFR 63.7324 - What procedures must I use to demonstrate initial compliance with the opacity limits?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial Compliance Requirements § 63.7324... of 15 percent for a by-product coke oven battery on a normal coking cycle or 20 percent for a by-product coke oven battery on batterywide extended coking, follow the test methods and procedures in...

  8. Battery Calendar Life Estimator Manual Modeling and Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jon P. Christophersen; Ira Bloom; Ed Thomas

    2012-10-01

    The Battery Life Estimator (BLE) Manual has been prepared to assist developers in their efforts to estimate the calendar life of advanced batteries for automotive applications. Testing requirements and procedures are defined by the various manuals previously published under the United States Advanced Battery Consortium (USABC). The purpose of this manual is to describe and standardize a method for estimating calendar life based on statistical models and degradation data acquired from typical USABC battery testing.

  9. Battery Life Estimator Manual Linear Modeling and Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jon P. Christophersen; Ira Bloom; Ed Thomas

    2009-08-01

    The Battery Life Estimator (BLE) Manual has been prepared to assist developers in their efforts to estimate the calendar life of advanced batteries for automotive applications. Testing requirements and procedures are defined by the various manuals previously published under the United States Advanced Battery Consortium (USABC). The purpose of this manual is to describe and standardize a method for estimating calendar life based on statistical models and degradation data acquired from typical USABC battery testing.

  10. Testing activities at the National Battery Test Laboratory

    NASA Astrophysics Data System (ADS)

    Hornstra, F.; Deluca, W. H.; Mulcahey, T. P.

    The National Battery Test Laboratory (NBTL) is an Argonne National Laboratory facility for testing, evaluating, and studying advanced electric storage batteries. The facility tests batteries developed under Department of Energy programs and from private industry. These include batteries intended for future electric vehicle (EV) propulsion, electric utility load leveling (LL), and solar energy storage. Since becoming operational, the NBTL has evaluated well over 1400 cells (generally in the form of three- to six-cell modules, but up to 140-cell batteries) of various technologies. Performance characterization assessments are conducted under a series of charge/discharge cycles with constant current, constant power, peak power, and computer simulated dynamic load profile conditions. Flexible charging algorithms are provided to accommodate the specific needs of each battery under test. Special studies are conducted to explore and optimize charge procedures, to investigate the impact of unique load demands on battery performance, and to analyze the thermal management requirements of battery systems.

  11. The development of the ATC selection battery : a new procedure to make maximum use of available information when correcting correlations for restriction in range due to selection.

    DOT National Transportation Integrated Search

    1978-09-01

    A five-test selection battery was given to select Air Traffic Controllers. Data were collected on two new tests being considered for incorporation into the battery. To determine the utility of the old and new tests, it is necessary to correlate the t...

  12. 40 CFR 63.7324 - What procedures must I use to demonstrate initial compliance with the opacity limits?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of 15 percent for a by-product coke oven battery on a normal coking cycle or 20 percent for a by-product coke oven battery on batterywide extended coking, follow the test methods and procedures in...

  13. Characteristics of the Test Components of the IELTS Battery: Australian Trial Data.

    ERIC Educational Resources Information Center

    Griffin, Patrick

    Results of the International English Language Testing System (IELTS) battery trials in Australia are reported. The IELTS tests of productive language skills use direct assessment strategies and subjective scoring according to detailed guidelines. The receptive skills tests use indirect assessment strategies and clerical scoring procedures.…

  14. NASA Handbook for Nickel-Hydrogen Batteries

    NASA Technical Reports Server (NTRS)

    Dunlop, James D.; Gopalakrishna, M. Rao; Yi, Thomas Y.

    1993-01-01

    Nickel-hydrogen (NiH2) batteries are finding more applications in the aerospace energy storage. Since 1983, NiH2 batteries have become the primary energy storage system used for Geosynchronous-Orbit (GEO) Satellites. The first NASA application for NiH2 batteries was the Low Earth Orbit (LEO) Hubble Space Telescope Satellite launched in 1990. The handbook was prepared as a reference book to aid in the application of this technology. That is, to aid in the cell and battery design, procurement, testing, and handling of NiH2 batteries. The design of individual pressure vessel NiH2 cells is covered in Chapter l. LEO and GEO applications and their requirements are discussed in Chapter 2. The design of NiH2 batteries for both GEO and LEO applications is discussed in Chapter 3. Advanced design concepts such as the common pressure vessel and bipolar NiH2 batteries are described in Chapter 4. Performance data are presented in Chapter 5. Storage and handling of the NiH2 cells and batteries are discussed in Chapter 6. Standard test procedures are presented in Chapter 7. Cell and battery procurements are discussed in Chapter 8. Finally, safety procedures are discussed in Chapter 9.

  15. Acceptance Equipment System Data Acquisition and Processing Utility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fakhro, Rowan

    2015-02-01

    My internship at Sandia National Laboratories took place in the Department of Sensors and Embedded Systems, which is tasked with, among many things, the non-destructive testing of thermal batteries. The Acceptance Equipment System (AES) is a flexible rack system designed to electrically test thermal batteries individually for internal defects before they are stored in the battery stock pile. Aside from individual testing, data acquired by the AES is used for many things including trending and catching outliers within the tolerance levels of a particular battery type, allowing for the development of more refined acceptance requirements and testing procedures.

  16. Evaluation Plan for the Computerized Adaptive Vocational Aptitude Battery.

    ERIC Educational Resources Information Center

    Green, Bert F.; And Others

    The United States Armed Services are planning to introduce computerized adaptive testing (CAT) into the Armed Services Vocational Aptitude Battery (ASVAB), which is a major part of the present personnel assessment procedures. Adaptive testing will improve efficiency greatly by assessing each candidate's answers as the test progresses and posing…

  17. GENETIC ACTIVITY PROFILES AND PATTERN RECOGNITION IN TEST BATTERY SELECTION (JOURNAL VERSION)

    EPA Science Inventory

    Computer-generated genetic activity profiles and pairwise matching procedures may aid in the selection of the most appropriate short-term bioassays to be used in test batteries for the evaluation of the genotoxicity of a given chemical or group of chemicals. Selection of test bat...

  18. Hybrid energy storage test procedures and high power battery project FY-1995 interim report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunt, G.L.

    1995-12-01

    Near the end of FY 1994, DOE provided funding and guidance to INEL for two separate but closely related tasks involving high power energy storage technology. One task was intended to develop and refine application-specific test procedures appropriate to high power energy storage devices for potential use in hybrid vehicles, including batteries, ultracapacitors, flywheels, and similar devices. The second task was intended to characterize the high power capabilities of presently available battery technologies, as well as eventually to evaluate the potential high power capabilities of advanced battery technologies such as those being developed by the USABC. Since the evaluation ofmore » such technologies is necessarily dependent to some extent on the availability of appropriate test methods, these two tasks have been closely coordinated. This report is intended to summarize the activities and results for both tasks accomplished during FY-1995.« less

  19. 40 CFR 798.6050 - Functional observational battery.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... observational battery is a noninvasive procedure designed to detect gross functional deficits in young adults.... This battery of tests is not intended to provide a detailed evaluation of neurotoxicity. It is designed... such factors as the comparative metabolism of the chemical and species sensitivity to the toxic effects...

  20. 40 CFR 798.6050 - Functional observational battery.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... observational battery is a noninvasive procedure designed to detect gross functional deficits in young adults.... This battery of tests is not intended to provide a detailed evaluation of neurotoxicity. It is designed... such factors as the comparative metabolism of the chemical and species sensitivity to the toxic effects...

  1. 40 CFR 798.6050 - Functional observational battery.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... observational battery is a noninvasive procedure designed to detect gross functional deficits in young adults.... This battery of tests is not intended to provide a detailed evaluation of neurotoxicity. It is designed... such factors as the comparative metabolism of the chemical and species sensitivity to the toxic effects...

  2. 40 CFR 798.6050 - Functional observational battery.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... observational battery is a noninvasive procedure designed to detect gross functional deficits in young adults.... This battery of tests is not intended to provide a detailed evaluation of neurotoxicity. It is designed... such factors as the comparative metabolism of the chemical and species sensitivity to the toxic effects...

  3. 40 CFR 798.6050 - Functional observational battery.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... observational battery is a noninvasive procedure designed to detect gross functional deficits in young adults.... This battery of tests is not intended to provide a detailed evaluation of neurotoxicity. It is designed... such factors as the comparative metabolism of the chemical and species sensitivity to the toxic effects...

  4. 75 FR 16957 - Energy Conservation Program: Test Procedures for Battery Chargers and External Power Supplies

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... Procedures C. Review of Single-Voltage External Power Supply Test Procedure D. Multiple-Voltage External...) Deletions of Existing Definitions (b) Revisions to Existing Definitions (c) Additions of New Definitions 4. Test Apparatus and General Instructions (a) Confidence Intervals (b) Temperature (c) AC Input Voltage...

  5. Development of satellite borne nickel hydrogen battery experiment equipment for ETS-6

    NASA Astrophysics Data System (ADS)

    Kuwashima, Saburou; Kamimori, Norimitsu; Kusawake, Hiroaki; Takahashi, Kazumichi

    1992-08-01

    An overview of the support rendered for the Engineering Test Satellite-6 (ETS-6) system integration test and protoflight test by the ETS-6 borne experimental nickel hydrogen battery development part is presented. Articles in the ETS-6 specifications and procedures related to the experimental battery were prepared or supported in preparation because of the battery's special characteristics such as its automatic control dependency on the bus voltage, thermal sensitivity equivalent to that of other batteries and so forth. System tests were witnessed and the acquired data were evaluated. Charging characteristics from 0 V were verified at trickle charging rate, using a flight scale model of Nickel Hydrogen (Ni-H2) Battery (NHB) after long term storage and an engineering model of the Ni-H2 Battery Controller (NHC). Requests for approval were submitted to the related self governing bodies in accordance with the Explosives Control Law when NHB's were charged and discharged. Installation and calibration data acquisition of the inner pressure sensors for the Ni-H2 battery cells for the flight model NHB were conducted and the battery assembly was started.

  6. 40 CFR 1037.525 - Special procedures for testing hybrid vehicles with power take-off.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of this section to allow testing hybrid vehicles other than electric-battery hybrids, consistent with... model, use good engineering judgment to select the vehicle type with the maximum number of PTO circuits... as needed to stabilize the battery at a full state of charge. For electric hybrid vehicles, we...

  7. Characterization testing of a 40 Ahr bipolar nickel hydrogen battery

    NASA Astrophysics Data System (ADS)

    Brewer, Jeffrey C.; Manzo, Michelle A.; Gahn, Randall F.

    1989-12-01

    In a continuing effort to develop NiH2 bipolar technology to a point where it can be used efficiently in space flight, testing of a second 40 Ahr, 10-cell bipolar battery has begun. This battery has undergone extensive characterization testing to determine the effects of such operating parameters as charge and discharge rates, temperature, and pressure. The fundamental design of this actively cooled bipolar battery is the same as the first battery. Most of the individual components, however, are from different manufacturers. Different testing procedures as well as certain unique battery characteristics make it difficult to directly compare the two sets of results. In general, the performance of this battery throughout characterization produced expected results. The main differences seen between the first and second batteries occurred during the high-rate discharge portion of the test matrix. The first battery also had poor high-rate discharge results, although better than those of the second battery. Minor changes were made to the battery frame design used for the first battery in an attempt to allow better gas access to the reaction sites for the second build and hopefully improve performance. The changes, however, did not improve the performance of the second battery and could have possibly contributed to the poorer performance that was observed. There are other component differences that could have contributed to the poorer performance of the second battery. The H2 electrode in the second battery was constructed with a Goretex backing which could have limited the high-rate current flow. The gas screen in the second battery had a larger mesh which again could have limited the high-rate current flow. Small scale 2 x 2 batteries are being tested to evaluate the effects of the component variations.

  8. Characterization testing of a 40 Ahr bipolar nickel hydrogen battery

    NASA Technical Reports Server (NTRS)

    Brewer, Jeffrey C.; Manzo, Michelle A.; Gahn, Randall F.

    1989-01-01

    In a continuing effort to develop NiH2 bipolar technology to a point where it can be used efficiently in space flight, testing of a second 40 Ahr, 10-cell bipolar battery has begun. This battery has undergone extensive characterization testing to determine the effects of such operating parameters as charge and discharge rates, temperature, and pressure. The fundamental design of this actively cooled bipolar battery is the same as the first battery. Most of the individual components, however, are from different manufacturers. Different testing procedures as well as certain unique battery characteristics make it difficult to directly compare the two sets of results. In general, the performance of this battery throughout characterization produced expected results. The main differences seen between the first and second batteries occurred during the high-rate discharge portion of the test matrix. The first battery also had poor high-rate discharge results, although better than those of the second battery. Minor changes were made to the battery frame design used for the first battery in an attempt to allow better gas access to the reaction sites for the second build and hopefully improve performance. The changes, however, did not improve the performance of the second battery and could have possibly contributed to the poorer performance that was observed. There are other component differences that could have contributed to the poorer performance of the second battery. The H2 electrode in the second battery was constructed with a Goretex backing which could have limited the high-rate current flow. The gas screen in the second battery had a larger mesh which again could have limited the high-rate current flow. Small scale 2 x 2 batteries are being tested to evaluate the effects of the component variations.

  9. Kurt Goldstein's test battery.

    PubMed

    Eling, Paul

    2015-02-01

    Kurt Goldstein was a founder of clinical neuropsychology. This thesis is illustrated with a description of Goldstein's test battery that he used as a screening instrument in a special clinic for soldiers in World War I. Parts of the battery were also used for neuropsychological rehabilitation. Goldstein's early work in Germany focused on both neuropsychological assessment and rehabilitation. He was interested in how individuals go about compensating for their deficits, The notion of ecological validity (Lebenswahr vs Lebensfremd), only becoming widely popular in the nineteen-eighties, played an important role in Goldstein's selection of test procedures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Battery algorithm verification and development using hardware-in-the-loop testing

    NASA Astrophysics Data System (ADS)

    He, Yongsheng; Liu, Wei; Koch, Brain J.

    Battery algorithms play a vital role in hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs), extended-range electric vehicles (EREVs), and electric vehicles (EVs). The energy management of hybrid and electric propulsion systems needs to rely on accurate information on the state of the battery in order to determine the optimal electric drive without abusing the battery. In this study, a cell-level hardware-in-the-loop (HIL) system is used to verify and develop state of charge (SOC) and power capability predictions of embedded battery algorithms for various vehicle applications. Two different batteries were selected as representative examples to illustrate the battery algorithm verification and development procedure. One is a lithium-ion battery with a conventional metal oxide cathode, which is a power battery for HEV applications. The other is a lithium-ion battery with an iron phosphate (LiFePO 4) cathode, which is an energy battery for applications in PHEVs, EREVs, and EVs. The battery cell HIL testing provided valuable data and critical guidance to evaluate the accuracy of the developed battery algorithms, to accelerate battery algorithm future development and improvement, and to reduce hybrid/electric vehicle system development time and costs.

  11. Electric and hybrid vehicles charge efficiency tests of ESB EV-106 lead acid batteries

    NASA Technical Reports Server (NTRS)

    Rowlette, J. J.

    1981-01-01

    Charge efficiencies were determined by measurements made under widely differing conditions of temperature, charge procedure, and battery age. The measurements were used to optimize charge procedures and to evaluate the concept of a modified, coulometric state of charge indicator. Charge efficiency determinations were made by measuring gassing rates and oxygen fractions. A novel, positive displacement gas flow meter which proved to be both simple and highly accurate is described and illustrated.

  12. Evaluation of a Schatz heat battery on a flexible-fueled vehicle

    NASA Astrophysics Data System (ADS)

    Piotrowski, Gregory K.; Schaefer, Ronald M.

    1991-09-01

    The evaluation is described of a Schatz Heat Battery as a means of reducing cold start emissions from a motor vehicle fueled with both gasoline and M85 high methanol blend fuel. The evaluation was conducted at both 20 and 75 F ambient temperatures. The test vehicle was a flexible fueled 1990 Audi 80 supplied by Volkswagen of America. A description is included of the test vehicle, the test facilities, the analytical methods and test procedures used.

  13. Evaluation of a Schatz heat battery on a flexible-fueled vehicle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piotrowski, G.K.; Schaefer, R.M.

    The report describes the evaluation of a Schatz Heat Battery as a means of reducing cold start emissions from a motor vehicle fueled with both gasoline and M85 high methanol blend fuel. The evaluation was conducted at both 20 F and 75 F ambient temperatures. The test vehicle was a flexible-fueled 1990 Audi 80 supplied by Volkswagen of America. The report also includes a description of the test vehicle, the test facilities, the analytical methods and test procedures used.

  14. Estimating Creativity with a Multiple-Measurement Approach within Scientific and Artistic Domains

    ERIC Educational Resources Information Center

    Agnoli, Sergio; Corazza, Giovanni E.; Runco, Mark A.

    2016-01-01

    This article presents the structure and the composition of a newly developed multifaceted test battery for the measurement of creativity within scientific and artistic domains. By integrating existing procedures for the evaluation of creativity, the new battery promises to become a comprehensive assessment of creativity, encompassing both…

  15. Technical Manual for Batteries, Navy Lithium Safety Program Responsibilities and Procedures

    DTIC Science & Technology

    2004-08-19

    lithium ion batteries and all equipment powered by lithium electrochemical power source(s) through all phases of the life of such systems. The purpose of this manual is to establish safety guidelines for the selection, design, testing, evaluation, use, packaging, storage, transportation and disposal of lithium

  16. Nickel hydrogen battery cell storage matrix test

    NASA Technical Reports Server (NTRS)

    Wheeler, James R.; Dodson, Gary W.

    1993-01-01

    Test were conducted to evaluate post storage performance of nickel hydrogen cells with various design variables, the most significant being nickel precharge versus hydrogen precharge. Test procedures and results are presented in outline and graphic form.

  17. Accelerated test plan for nickel cadmium spacecraft batteries

    NASA Technical Reports Server (NTRS)

    Hennigan, T. J.

    1973-01-01

    An accelerated test matrix is outlined that includes acceptance, baseline and post-cycling tests, chemical and physical analyses, and the data analysis procedures to be used in determining the feasibility of an accelerated test for sealed, nickel cadmium cells.

  18. Factor Structure and Validation of a Set of Readiness Measures.

    ERIC Educational Resources Information Center

    Kaufman, Maurice; Lynch, Mervin

    A study was undertaken to identify the factor structure of a battery of readiness measures and to demonstrate the concurrent and predictive validity of one instrument in that battery--the Pre-Reading Screening Procedures (PSP). Concurrent validity was determined by examining the correlation of the PSP with the Metropolitan Readiness Test (MRT),…

  19. 14 CFR 382.127 - What procedures apply to stowage of battery-powered mobility aids?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false What procedures apply to stowage of battery... What procedures apply to stowage of battery-powered mobility aids? (a) Whenever baggage compartment... a passenger's battery-powered wheelchair or other similar mobility device, including the battery, as...

  20. 14 CFR 382.127 - What procedures apply to stowage of battery-powered mobility aids?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false What procedures apply to stowage of battery... What procedures apply to stowage of battery-powered mobility aids? (a) Whenever baggage compartment... a passenger's battery-powered wheelchair or other similar mobility device, including the battery, as...

  1. 14 CFR 382.127 - What procedures apply to stowage of battery-powered mobility aids?

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false What procedures apply to stowage of battery... What procedures apply to stowage of battery-powered mobility aids? (a) Whenever baggage compartment... a passenger's battery-powered wheelchair or other similar mobility device, including the battery, as...

  2. 14 CFR 382.127 - What procedures apply to stowage of battery-powered mobility aids?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false What procedures apply to stowage of battery... What procedures apply to stowage of battery-powered mobility aids? (a) Whenever baggage compartment... a passenger's battery-powered wheelchair or other similar mobility device, including the battery, as...

  3. 14 CFR 382.127 - What procedures apply to stowage of battery-powered mobility aids?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false What procedures apply to stowage of battery... What procedures apply to stowage of battery-powered mobility aids? (a) Whenever baggage compartment... a passenger's battery-powered wheelchair or other similar mobility device, including the battery, as...

  4. Cross-validation of a Shortened Battery for the Assessment of Dysexecutive Disorders in Alzheimer Disease.

    PubMed

    Godefroy, Olivier; Martinaud, Olivier; Verny, Marc; Mosca, Chrystèle; Lenoir, Hermine; Bretault, Eric; Devendeville, Agnès; Diouf, Momar; Pere, Jean-Jacques; Bakchine, Serge; Delabrousse-Mayoux, Jean-Philippe; Roussel, Martine

    2016-01-01

    The frequency of executive disorders in mild-to-moderate Alzheimer disease (AD) has been demonstrated by the application of a comprehensive battery. The present study analyzed data from 2 recent multicenter studies based on the same executive battery. The objective was to derive a shortened battery by using the GREFEX population as a training dataset and by cross-validating the results in the REFLEX population. A total of 102 AD patients of the GREFEX study (MMSE=23.2±2.9) and 72 patients of the REFLEX study (MMSE=20.8±3.5) were included. Tests were selected and receiver operating characteristic curves were generated relative to the performance of 780 controls from the GREFEX study. Stepwise logistic regression identified 3 cognitive tests (Six Elements Task, categorical fluency and Trail Making Test B error) and behavioral disorders globally referred as global hypoactivity (P=0.0001, all). This shortened battery was as accurate as the entire GREFEX battery in diagnosing dysexecutive disorders in both training group and the validation group. Bootstrap procedure confirmed the stability of AUC. A shortened battery based on 3 cognitive tests and 3 behavioral domains provides a high diagnosis accuracy of executive disorders in mild-to-moderate AD.

  5. Accelerated test design

    NASA Technical Reports Server (NTRS)

    Mcdermott, P. P.

    1980-01-01

    The design of an accelerated life test program for electric batteries is discussed. A number of observations and suggestions on the procedures and objectives for conducting an accelerated life test program are presented. Equations based on nonlinear regression analysis for predicting the accelerated life test parameters are discussed.

  6. Electric vehicle test report Cutler-Hammer Corvette

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Vehicles were characterized for the state of the art assessment of electric vehicles. The vehicle evaluated was a Chevrolet Corvette converted to electric operation. The original internal combustion engine was replaced by an electric traction motor. Eighteen batteries supplied the electrical energy. A controller, an onboard battery charger, and several dashboard instruments completed the conversion. The emphasis was on the electrical portion of the drive train, although some analysis and discussion of the mechanical elements are included. Tests were conducted both on the road (actually a mile long runway) and in a chassis dynamometer equipped laboratory. The majority of the tests performed were according to SAE Procedure J227a and included maximum effort accelerations, constant speed range, and cyclic range. Some tests that are not a part of the SAE Procedure J227a are described and the analysis of the data from all tests is discussed.

  7. The Behavior Assessment Battery: A Preliminary Study of Non-Stuttering Pakistani Grade-School Children

    ERIC Educational Resources Information Center

    Vanryckeghem, Martine; Mukati, Samad A.

    2006-01-01

    Background: In recent years, the importance of a multimodal approach to the assessment of the person who stutters (PWS) has become increasingly recognized. The Behavior Assessment Battery (BAB), which is a normed test procedure developed by G. Brutten, makes it possible to assess the multidimensional facets of this disorder. The emotional and…

  8. Performance analysis of ten brands of batteries for hearing aids

    PubMed Central

    Penteado, Silvio Pires; Bento, Ricardo Ferreira

    2013-01-01

    Summary Introduction: Comparison of the performance of hearing instrument batteries from various manufacturers can enable otologists, audiologists, or final consumers to select the best products, maximizing the use of these materials. Aim: To analyze the performance of ten brands of batteries for hearing aids available in the Brazilian marketplace. Methods: Hearing aid batteries in four sizes were acquired from ten manufacturers and subjected to the same test conditions in an acoustic laboratory. Results: The results obtained in the laboratory contrasted with the values reported by manufacturers highlighted significant discrepancies, besides the fact that certain brands in certain sizes perform better on some tests, but does not indicate which brand is the best in all sizes. Conclusions: It was possible to investigate the performance of ten brands of hearing aid batteries and describe the procedures to be followed for leakage, accidental intake, and disposal. PMID:25992026

  9. Analyse experimentale des performances d'une batterie au lithium pour l'aeronautique

    NASA Astrophysics Data System (ADS)

    Bonnin, Romain

    Ce memoire a pour objectif d'identifier et d'etudier les performances necessaires pour qu'une batterie au lithium puisse etre utilisee dans le secteur de l'aeronautique. C'est pourquoi dans le cadre de notre recherche, nous allons proposer une procedure de tests permettant d'analyser et de determiner si la batterie au lithium peut etre implantee dans un avion. En vue de repondre a l'analyse des performances, une etude des fonctionnalites demandees par l'avion ainsi que des normes preexistantes vont etre effectuees. Suite a cette etape, nous allons elaborer un banc d'essais. Une fois le banc d'essais acheve, nous allons tester une batterie au lithium qui est supposee disposer de toutes les caracteristiques techniques requises pour etre implantee dans un avion. Ces tests nous permettront donc d'emettre un avis sur l'utilisation des batteries au lithium dans le domaine de l'aeronautique.

  10. Tested Demonstrations.

    ERIC Educational Resources Information Center

    Gilbert, George L., Ed.

    1984-01-01

    Procedures for two demonstrations are presented. The first is a demonstration of chemiluminescence. The second is a demonstration using a secondary battery constructed from common household articles. (JN)

  11. 40 CFR 63.7322 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... rate of particulate matter (lb/ton of coke) from a control device applied to pushing emissions where a... combined weight in tons of coke pushed during the duration of each test run according to the procedures in...

  12. 40 CFR 63.7322 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... rate of particulate matter (lb/ton of coke) from a control device applied to pushing emissions where a... combined weight in tons of coke pushed during the duration of each test run according to the procedures in...

  13. 40 CFR 63.7322 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... rate of particulate matter (lb/ton of coke) from a control device applied to pushing emissions where a... combined weight in tons of coke pushed during the duration of each test run according to the procedures in...

  14. 40 CFR 63.7322 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... rate of particulate matter (lb/ton of coke) from a control device applied to pushing emissions where a... combined weight in tons of coke pushed during the duration of each test run according to the procedures in...

  15. 40 CFR 63.7322 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... rate of particulate matter (lb/ton of coke) from a control device applied to pushing emissions where a... combined weight in tons of coke pushed during the duration of each test run according to the procedures in...

  16. 76 FR 31749 - Energy Conservation Program for Certain Consumer Appliances: Test Procedures for Battery Chargers...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    .... 6 at p. 1; AHAM, No. 10 at p. 8) Delta-Q cautioned ``against some overlap with any solar industry... electrical grid and the battery of many consumer photovoltaic (PV) and wind energy systems, as well as rapid... for residential PV systems that employ these higher output voltage devices. (ASAP, No. 11 at p. 2; PG...

  17. Deep Reconditioning Testing for near Earth Orbits

    NASA Technical Reports Server (NTRS)

    Betz, F. E.; Barnes, W. L.

    1984-01-01

    The problems and benefits of deep reconditioning to near Earth orbit missions with high cycle life and shallow discharge depth requirements is discussed. A simple battery level approach to deep reconditioning of nickel cadmium batteries in near Earth orbit is considered. A test plan was developed to perform deep reconditioning in direct comparison with an alternative trickle charge approach. The results demonstrate that the deep reconditioning procedure described for near Earth orbit application is inferior to the alternative of trickle charging.

  18. Capacity recovery after storage negatively precharged nickel hydrogen cells

    NASA Technical Reports Server (NTRS)

    Lowery, John E.

    1993-01-01

    Tests were conducted to investigate the recovery of capacity lost during open circuit storage of negatively precharged nickel hydrogen batteries. Four Eagle Picher RNH-90-3 cells were used in the tests. Recovery procedures and test results are presented in outline and graphic form.

  19. Crosscheck Principle in Pediatric Audiology Today: A 40-Year Perspective

    PubMed Central

    2016-01-01

    The crosscheck principle is just as important in pediatric audiology as it was when first described 40 years ago. That is, no auditory test result should be accepted and used in the diagnosis of hearing loss until it is confirmed or crosschecked by one or more independent measures. Exclusive reliance on only one or two tests, even objective auditory measures, may result in a auditory diagnosis that is not clear or perhaps incorrect. On the other hand, close and careful analysis of findings for a test battery consisting of objective procedures and behavioral tests whenever feasible usually leads to prompt and accurate diagnosis of auditory dysfunction. This paper provides a concise review of the crosscheck principle from its introduction to its clinical application today. The review concludes with a description of a modern test battery for pediatric hearing assessment that supplements traditional behavioral tests with a variety of independent objective procedures including aural immittance measures, otoacoustic emissions, and auditory evoked responses. PMID:27626077

  20. Crosscheck Principle in Pediatric Audiology Today: A 40-Year Perspective.

    PubMed

    Hall, James W

    2016-09-01

    The crosscheck principle is just as important in pediatric audiology as it was when first described 40 years ago. That is, no auditory test result should be accepted and used in the diagnosis of hearing loss until it is confirmed or crosschecked by one or more independent measures. Exclusive reliance on only one or two tests, even objective auditory measures, may result in a auditory diagnosis that is not clear or perhaps incorrect. On the other hand, close and careful analysis of findings for a test battery consisting of objective procedures and behavioral tests whenever feasible usually leads to prompt and accurate diagnosis of auditory dysfunction. This paper provides a concise review of the crosscheck principle from its introduction to its clinical application today. The review concludes with a description of a modern test battery for pediatric hearing assessment that supplements traditional behavioral tests with a variety of independent objective procedures including aural immittance measures, otoacoustic emissions, and auditory evoked responses.

  1. Battery Test Manual For 12 Volt Start/Stop Hybrid Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belt, Jeffrey R.

    This manual was prepared by and for the United Stated Advanced Battery Consortium (USABC) Electrochemical Energy Storage Team. It is based on the targets established for 12 Volt Start/Stop energy storage development and is similar (with some important changes) to an earlier manual for the former FreedomCAR program. The specific procedures were developed primarily to characterize the performance of energy storage devices relative to the USABC requirements. However, it is anticipated that these procedures will have some utility for characterizing 12 Volt Start/Stop hybrid energy storage device behavior in general.

  2. Analysis of Ageing Effect on Li-Polymer Batteries

    PubMed Central

    Barcellona, Simone; Brenna, Morris; Foiadelli, Federica; Longo, Michela; Piegari, Luigi

    2015-01-01

    Lithium-ion batteries are a key technology for current and future energy storage in mobile and stationary application. In particular, they play an important role in the electrification of mobility and therefore the battery lifetime prediction is a fundamental aspect for successful market introduction. Numerous studies developed ageing models capable of predicting battery life span. Most of the previous works compared the effect of the ageing factors to a battery's cycle life. These cycles are identical, which is not the case for electric vehicles applications. Indeed, most of the available information is based on results from laboratory testing, under very controlled environments, and using ageing protocols, which may not correctly reflect the actual utilization. For this reason, it is important to link the effect of duty cycles with the ageing of the batteries. This paper proposes a simple method to investigate the effect of the duty cycle on the batteries lifetime through tests performed on different cells for different kinds of cycle. In this way, a generic complex cycle can be seen as a composition of elemental cycles by means of Rainflow procedures. Consequently, the ageing due to any cycle can be estimated starting from the knowledge of simpler cycles. PMID:26236775

  3. An evaluation of potentially useful separator materials for nickel-cadmium (Ni-Cd] satellite batteries

    NASA Technical Reports Server (NTRS)

    Baker, H. A.; Toner, S. D.; Cuthrell, W. F.

    1974-01-01

    An evaluation intended to determine the potential suitability and probable efficacy of a group of separator materials for use in nickel-cadmium (Ni-Cd) satellite batteries was carried out. These results were obtained using test procedures established in an earlier evaluation of other separator materials, some of which were used in experimental battery cells subjected to simulated use conditions. The properties that appear to be most important are: high electrolyte absorptivity, good electrolyte retention, low specific resistivity, rapid wettability and low resistance to air permeation. Wicking characteristics and wet-out time seem to be more important with respect to the initial filling of the battery with the electrolyte.

  4. Procedures for central auditory processing screening in schoolchildren.

    PubMed

    Carvalho, Nádia Giulian de; Ubiali, Thalita; Amaral, Maria Isabel Ramos do; Santos, Maria Francisca Colella

    2018-03-22

    Central auditory processing screening in schoolchildren has led to debates in literature, both regarding the protocol to be used and the importance of actions aimed at prevention and promotion of auditory health. Defining effective screening procedures for central auditory processing is a challenge in Audiology. This study aimed to analyze the scientific research on central auditory processing screening and discuss the effectiveness of the procedures utilized. A search was performed in the SciELO and PUBMed databases by two researchers. The descriptors used in Portuguese and English were: auditory processing, screening, hearing, auditory perception, children, auditory tests and their respective terms in Portuguese. original articles involving schoolchildren, auditory screening of central auditory skills and articles in Portuguese or English. studies with adult and/or neonatal populations, peripheral auditory screening only, and duplicate articles. After applying the described criteria, 11 articles were included. At the international level, central auditory processing screening methods used were: screening test for auditory processing disorder and its revised version, screening test for auditory processing, scale of auditory behaviors, children's auditory performance scale and Feather Squadron. In the Brazilian scenario, the procedures used were the simplified auditory processing assessment and Zaidan's battery of tests. At the international level, the screening test for auditory processing and Feather Squadron batteries stand out as the most comprehensive evaluation of hearing skills. At the national level, there is a paucity of studies that use methods evaluating more than four skills, and are normalized by age group. The use of simplified auditory processing assessment and questionnaires can be complementary in the search for an easy access and low-cost alternative in the auditory screening of Brazilian schoolchildren. Interactive tools should be proposed, that allow the selection of as many hearing skills as possible, validated by comparison with the battery of tests used in the diagnosis. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  5. CAT Procedures for Passage-Based Tests.

    ERIC Educational Resources Information Center

    Thompson, Tony D.; Davey, Tim

    Methods to control the test construct and the efficiency of a computerized adaptive test (CAT) were studied in the context of a reading comprehension test given as a part of a battery of tests for college admission. A goal of the study was to create test scores that were interchangeable with those from a fixed form paper and pencil test. The first…

  6. Employment Testing and the Selection of School Support Personnel: A Validation Study

    ERIC Educational Resources Information Center

    Organt, Gerald J.

    1975-01-01

    The present paper describes an attempt to establish a paper and pencil test battery for improving predictive efficiency in the selection of supporting services personnel at Montgomery County Public Schools and a report on the validation of such a procedure. (Author)

  7. Analysis of lead-acid battery accelerated testing data

    NASA Astrophysics Data System (ADS)

    Clifford, J. E.; Thomas, R. E.

    1983-06-01

    Battelle conducted an independent review and analysis of the accelerated test procedures and test data obtained by Exide in the 3 year Phase 1 program to develop advanced lead acid batteries for utility load leveling. Of special importance is the extensive data obtained in deep discharge cycling tests on 60 cells at elevated temperatures over a 2-1/2 year period. The principal uncertainty in estimating cell life relates to projecting cycle life data at elevated temperature to the lower operating temperatures. The accelerated positive grid corrosion test involving continuous overcharge at 500C provided some indication of the degree of grid corrosion that might be tolerable before failure. The accelerated positive material shedding test was not examined in any detail. Recommendations are made for additional studies.

  8. The testing of batteries linked to supercapacitors with electrochemical impedance spectroscopy: A comparison between Li-ion and valve regulated lead acid batteries

    NASA Astrophysics Data System (ADS)

    Ferg, Ernst; Rossouw, Claire; Loyson, Peter

    2013-03-01

    For electric vehicles, a supercapacitor can be coupled to the electrical system in order to increase and optimize the energy and power densities of the drive system during acceleration and regenerative breaking. This study looked at the charge acceptance and maximum discharge ability of a valve regulated lead acid (VRLA) and a Li-ion battery connected in parallel to supercapacitors. The test procedure evaluated the advantage of using a supercapacitor at a 2 F:1 Ah ratio with the battery types at various states of charge (SoC). The results showed that about 7% of extra charge was achieved over a 5-s test time for a Li-ion hybrid system at 20% SoC, whereas at the 80% SoC the additional capacity was approximately 16%. While for the VRLA battery hybrid system, an additional charge of up to 20% was achieved when the battery was at 80% SoC, with little or no benefit at the 20% SoC. The advantage of the supercapacitor in parallel with a VRLA battery was noticeable on its discharge ability, where significant extra capacity was achieved for short periods of time for a battery at the 60% and 40% SoC when compared to the Li-ion hybrid system. The study also made use of Electrochemical Impedance Spectroscopy (EIS) with a suitable equivalent circuit model to explain, in particular, the internal resistance and capacitance differences observed between the different battery chemistries with and without a supercapacitor.

  9. Job-Derived Selection: Follow Up Report. Technical Report No. 4.

    ERIC Educational Resources Information Center

    McCormick, Ernest J.; And Others

    A study dealt with the use of the Position Analysis Questionnaire (PAQ) within a job component validity framework as the basis for estimating aptitude requirements of jobs represented by scores on commercially available tests as contrasted with scores on General Aptitude Test Battery (GATB) tests. Procedures generally consisted of the use of job…

  10. [European Portuguese EARS test battery adaptation].

    PubMed

    Alves, Marisa; Ramos, Daniela; Oliveira, Graça; Alves, Helena; Anderson, Ilona; Magalhães, Isabel; Martins, Jorge H; Simões, Margarida; Ferreira, Raquel; Fonseca, Rita; Andrade, Susana; Silva, Luís; Ribeiro, Carlos; Ferreira, Pedro Lopes

    2014-01-01

    The use of adequate assessment tools in health care is crucial for the management of care. The lack of specific tools in Portugal for assessing the performance of children who use cochlear implants motivated the translation and adaptation of the EARS (Evaluation of Auditory Responses to Speech) test battery into European Portuguese. This test battery is today one of the most commonly used by (re)habilitation teams of deaf children who use cochlear implants worldwide. The goal to be achieved with the validation of EARS was to provide (re)habilitation teams an instrument that enables: (i) monitoring the progress of individual (re)habilitation, (ii) managing a (re)habilitation program according to objective results, comparable between different (re)habilitation teams, (iii) obtaining data that can be compared with the results of international teams, and (iv) improving engagement and motivation of the family and other professionals from local teams. For the test battery translation and adaptation process, the adopted procedures were the following: (i) translation of the English version into European Portuguese by a professional translator, (ii) revision of the translation performed by an expert panel, including doctors, speech-language pathologists and audiologists, (iii) adaptation of the test stimuli by the team's speechlanguage pathologist, and (iv) further review by the expert panel. For each of the tests that belong to the EARS battery, the introduced adaptations and adjustments are presented, combining the characteristics and objectives of the original tests with the linguistic and cultural specificities of the Portuguese population. The difficulties that have been encountered during the translation and adaptation process and the adopted solutions are discussed. Comparisons are made with other versions of the EARS battery. We defend that the translation and the adaptation process followed for the EARS test battery into European Portuguese was correctly conducted, respecting the characteristics of the original instruments and adapting the test stimuli to the linguistic and cultural reality of the Portuguese population, thus meeting the goals that have been set.

  11. 4. Photocopy of photograph showing battery acquisition radar from 'Procedures ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Photocopy of photograph showing battery acquisition radar from 'Procedures and Drills for the NIKE Hercules Missile Battery,' Department of the Army Field Manual, FM-44-82 from Institute for Military History, Carlisle Barracks, Carlisle, PA, 1959 - NIKE Missile Battery PR-79, East Windsor Road south of State Route 101, Foster, Providence County, RI

  12. Differential prediction of FAA Academy performance on the basis of gender and written air traffic control specialist aptitude test scores.

    DOT National Transportation Integrated Search

    1996-04-01

    The technical fairness of the written air traffic control specialist (ATCS) aptitude test battery was investigated within the framework of the Uniform Guidelines on Employee Selection Procedures (29 CFR 1607). First, the adverse impact of using a com...

  13. NPS Solar Cell Array Tester Cubesat Flight Testing and Integration

    DTIC Science & Technology

    2014-09-01

    with current (I). P V I      (2.1) This is significant because the battery discharge test will not lineup perfectly with Figure 12...accordance with the charging procedures [13]. 3. NPS-SCAT Power Budget A power budget analysis was performed to determine if the NPS-SCAT is self...using procedures developed by Marissa Brummitt, and with the assistance of Adam Hill, NPS-SCAT Program Manager. 1. ELaNa IV Random Vibration Levels

  14. Poly(vinylidene fluoride-hexafluoropropylene) polymer electrolyte for paper-based and flexible battery applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aliahmad, Nojan; Shrestha, Sudhir; Varahramyan, Kody

    2016-06-15

    Paper-based batteries represent a new frontier in battery technology. However, low-flexibility and poor ionic conductivity of solid electrolytes have been major impediments in achieving practical mechanically flexible batteries. This work discuss new highly ionic conductive polymer gel electrolytes for paper-based battery applications. In this paper, we present a poly(vinylidene fluoride-hexafluoropropylene) (PVDH-HFP) porous membrane electrolyte enhanced with lithium bis(trifluoromethane sulphone)imide (LiTFSI) and lithium aluminum titanium phosphate (LATP), with an ionic conductivity of 2.1 × 10{sup −3} S cm{sup −1}. Combining ceramic (LATP) with the gel structure of PVDF-HFP and LiTFSI ionic liquid harnesses benefits of ceramic and gel electrolytes in providingmore » flexible electrolytes with a high ionic conductivity. In a flexibility test experiment, bending the polymer electrolyte at 90° for 20 times resulted in 14% decrease in ionic conductivity. Efforts to further improving the flexibility of the presented electrolyte are ongoing. Using this electrolyte, full-cell batteries with lithium titanium oxide (LTO) and lithium cobalt oxide (LCO) electrodes and (i) standard metallic current collectors and (ii) paper-based current collectors were fabricated and tested. The achieved specific capacities were (i) 123 mAh g{sup −1} for standard metallic current collectors and (ii) 99.5 mAh g{sup −1} for paper-based current collectors. Thus, the presented electrolyte has potential to become a viable candidate in paper-based and flexible battery applications. Fabrication methods, experimental procedures, and test results for the polymer gel electrolyte and batteries are presented and discussed.« less

  15. Poly(vinylidene fluoride-hexafluoropropylene) polymer electrolyte for paper-based and flexible battery applications

    NASA Astrophysics Data System (ADS)

    Aliahmad, Nojan; Shrestha, Sudhir; Varahramyan, Kody; Agarwal, Mangilal

    2016-06-01

    Paper-based batteries represent a new frontier in battery technology. However, low-flexibility and poor ionic conductivity of solid electrolytes have been major impediments in achieving practical mechanically flexible batteries. This work discuss new highly ionic conductive polymer gel electrolytes for paper-based battery applications. In this paper, we present a poly(vinylidene fluoride-hexafluoropropylene) (PVDH-HFP) porous membrane electrolyte enhanced with lithium bis(trifluoromethane sulphone)imide (LiTFSI) and lithium aluminum titanium phosphate (LATP), with an ionic conductivity of 2.1 × 10-3 S cm-1. Combining ceramic (LATP) with the gel structure of PVDF-HFP and LiTFSI ionic liquid harnesses benefits of ceramic and gel electrolytes in providing flexible electrolytes with a high ionic conductivity. In a flexibility test experiment, bending the polymer electrolyte at 90° for 20 times resulted in 14% decrease in ionic conductivity. Efforts to further improving the flexibility of the presented electrolyte are ongoing. Using this electrolyte, full-cell batteries with lithium titanium oxide (LTO) and lithium cobalt oxide (LCO) electrodes and (i) standard metallic current collectors and (ii) paper-based current collectors were fabricated and tested. The achieved specific capacities were (i) 123 mAh g-1 for standard metallic current collectors and (ii) 99.5 mAh g-1 for paper-based current collectors. Thus, the presented electrolyte has potential to become a viable candidate in paper-based and flexible battery applications. Fabrication methods, experimental procedures, and test results for the polymer gel electrolyte and batteries are presented and discussed.

  16. Performance and Health Test Procedure for Grid Energy Storage Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baggu, Murali M; Smith, Kandler A; Friedl, Andrew

    A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: round-trip efficiency, standby losses, response time/accuracy, and useable energy/state of charge at different discharge/charge rates over the system's lifetime. The procedures are divided into reference performance tests, which require the system to be put in a test mode and are to be conducted in intervals, and real-time monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with littlemore » modification and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditure. Simulated results based on a detailed system simulation of a prototype system are provided as guideline.« less

  17. Learning to remember: cognitive training-induced attenuation of age-related memory decline depends on sex and cognitive demand, and can transfer to untrained cognitive domains.

    PubMed

    Talboom, Joshua S; West, Stephen G; Engler-Chiurazzi, Elizabeth B; Enders, Craig K; Crain, Ian; Bimonte-Nelson, Heather A

    2014-12-01

    Aging is associated with progressive changes in learning and memory. A potential approach to attenuate age-related cognitive decline is cognitive training. In this study, adult male and female rats were given either repeated exposure to a T-maze, or no exposure to any maze, and then tested on a final battery of cognitive tasks. Two groups of each sex were tested from 6 to 18 months old on the same T-maze; Group one received a version testing spatial reference memory, and Group two received only the procedural testing components with minimal cognitive demand. Groups three and four of each sex had no maze exposure until the final battery, and were comprised of aged or young rats, respectively. The final maze battery included the practiced T-maze plus two novel tasks, one with a similar, and one with a different, memory type to the practice task. Group five of each sex was not maze tested, serving as an aged control for the effects of maze testing on neurotrophin protein levels in cognitive brain regions. Results showed that adult intermittent cognitive training enhanced performance on the practice task when aged in both sexes, that cognitive training benefits transferred to novel tasks only in females, and that cognitive demand was necessary for these effects, since rats receiving only the procedural testing components showed no improvement on the final maze battery. Further, for both sexes, rats that showed faster learning when young demonstrated better memory when aged. Age-related increases in neurotrophin concentrations in several brain regions were revealed, which were related to performance on the training task only in females. This longitudinal study supports the tenet that cognitive training can help one remember later in life, with broader enhancements and associations with neurotrophins in females. Published by Elsevier Inc.

  18. Learning to remember: Cognitive training-induced attenuation of age-related memory decline depends on sex and cognitive demand, and can transfer to untrained cognitive domains

    PubMed Central

    Talboom, Joshua S.; West, Stephen G.; Engler-Chiurazzi, Elizabeth B.; Enders, Craig K.; Crain, Ian; Bimonte-Nelson, Heather A.

    2014-01-01

    Aging is associated with progressive changes in learning and memory. A potential approach to attenuate age-related cognitive decline is cognitive training. In this study, adult male and female rats were given either repeated exposure to a T-maze, or no exposure to any maze, and then tested on a final battery of cognitive tasks. Two groups of each sex were tested from 6-18 months old on the same T-maze; one group received a version testing spatial reference memory, and the other group received only the procedural testing components with minimal cognitive demand. Groups three and four of each sex had no maze exposure until the final battery, and were comprised of aged or young rats. The final maze battery included the practiced T-maze plus two novel tasks, one with a similar, and one with a different, memory type to the practice task. The fifth group of each sex was not maze tested, serving as an aged control for the effects of maze testing on neurotrophin protein levels in cognitive brain regions. Results showed that adult intermittent cognitive training enhanced performance on the practice task when aged in both sexes, that cognitive training benefits transferred to novel tasks only in females, and that cognitive demand was necessary for these effects since rats receiving only the procedural testing components showed no improvement on the final maze battery. Further, for both sexes, rats that showed faster learning when young demonstrated better memory when aged. Age-related increases in neurotrophin concentrations in several brain regions were revealed, which was related to performance on the training task only in females. This longitudinal study supports the tenet that cognitive training can help one remember later in life, with broader enhancements and associations with neurotrophins in females. PMID:25104561

  19. Component variations and their effects on bipolar nickel-hydrogen cell performance

    NASA Technical Reports Server (NTRS)

    Manzo, Michelle A.; Gahn, Randall F.; Gonzalez-Sanabria, Olga D.; Cataldo, Robert L.; Gemeiner, Russel P.

    1987-01-01

    A 50 cell bipolar nickel-hydrogen battery was assembled to demonstrate the feasibility of constructing a high voltage stack of cells. Various component combinations were tested in this battery. The battery had approximately 1 ampere-hour of capacity and was constructed from components with an active area of 2 x 2 inches. The components were parametrically varied to give a comparison of nickel electrodes, hydrogen electrodes, separators, fill procedures and electrolyte reservoir plate thicknesses. Groups of five cells were constructed using the same components; ten combinations were tested in all. The battery was thoroughly characterized at various change and discharge rates as well as with various pulse patterns and rates. Over a period of 1400 40-percent DOD LEO cycles some of the groups began to exhibit performance differences. In general, only separator variations had a significant effect on cell performance. It also appears that shunt currents may have been operating within the stack, resulting in electrolyte transfer from one cell to another, thus contributing to cell performance variations.

  20. Component variations and their effects on bipolar nickel-hydrogen cell performance

    NASA Technical Reports Server (NTRS)

    Manzo, Michelle A.; Gahn, Randall F.; Gonzalez-Sanabria, Olga D.; Cataldo, Robert L.; Gemeiner, Russel P.

    1987-01-01

    A 50 cell bipolar nickel-hydrogen battery was assembled to demonstrate the feasibility of constructing a high voltage stack of cells. Various component combinations were tested in this battery. The battery had approximately 1 ampere-hour of capacity and was constructed from components with an active area of 2" X 2". The components were parametrically varied to give a comparison of nickel electrodes, hydrogen electrodes, separators, fill procedures and electrolyte reservoir plate thicknesses. Groups of five cells were constructed using the same components; ten combinations were tested in all. The battery was thoroughly characterized at various change and discharge rates as well as with various pulse patterns and rates. Over a period of 1400 40% DOD LEO cycles some of the groups began to exhibit performance differences. In general, only separator variations had a significant effect on cell performance. It also appears that shunt currents may have been operating within the stack, resulting in electrolyte transfer from one cell to another, thus contributing to cell performance variations.

  1. Verification of a Remaining Flying Time Prediction System for Small Electric Aircraft

    NASA Technical Reports Server (NTRS)

    Hogge, Edward F.; Bole, Brian M.; Vazquez, Sixto L.; Celaya, Jose R.; Strom, Thomas H.; Hill, Boyd L.; Smalling, Kyle M.; Quach, Cuong C.

    2015-01-01

    This paper addresses the problem of building trust in online predictions of a battery powered aircraft's remaining available flying time. A set of ground tests is described that make use of a small unmanned aerial vehicle to verify the performance of remaining flying time predictions. The algorithm verification procedure described here uses a fully functional vehicle that is restrained to a platform for repeated run-to-functional-failure experiments. The vehicle under test is commanded to follow a predefined propeller RPM profile in order to create battery demand profiles similar to those expected in flight. The fully integrated aircraft is repeatedly operated until the charge stored in powertrain batteries falls below a specified lower-limit. The time at which the lower-limit on battery charge is crossed is then used to measure the accuracy of remaining flying time predictions. Accuracy requirements are considered in this paper for an alarm that warns operators when remaining flying time is estimated to fall below a specified threshold.

  2. Gene toxicity studies on titanium dioxide and zinc oxide nanomaterials used for UV-protection in cosmetic formulations.

    PubMed

    Landsiedel, Robert; Ma-Hock, Lan; Van Ravenzwaay, Ben; Schulz, Markus; Wiench, Karin; Champ, Samantha; Schulte, Stefan; Wohlleben, Wendel; Oesch, Franz

    2010-12-01

    Titanium dioxide and zinc oxide nanomaterials, used as UV protecting agents in sunscreens, were investigated for their potential genotoxicity in in vitro and in vivo test systems. Since standard OECD test methods are designed for soluble materials and genotoxicity testing for nanomaterials is still under revision, a battery of standard tests was used, covering different endpoints. Additionally, a procedure to disperse the nanomaterials in the test media and careful characterization of the dispersed test item was added to the testing methods. No genotoxicity was observed in vitro (Ames' Salmonella gene mutation test and V79 micronucleus chromosome mutation test) or in vivo (mouse bone marrow micronucleus test and Comet DNA damage assay in lung cells from rats exposed by inhalation). These results add to the still limited data base on genotoxicity test results with nanomaterials and provide congruent results of a battery of standard OECD test methods applied to nanomaterials.

  3. Fine-Tuning Cross-Battery Assessment Procedures: After Follow-Up Testing, Use All Valid Scores, Cohesive or Not

    ERIC Educational Resources Information Center

    Schneider, W. Joel; Roman, Zachary

    2018-01-01

    We used data simulations to test whether composites consisting of cohesive subtest scores are more accurate than composites consisting of divergent subtest scores. We demonstrate that when multivariate normality holds, divergent and cohesive scores are equally accurate. Furthermore, excluding divergent scores results in biased estimates of…

  4. Criterion-Related Validity: Assessing the Value of Subscores

    ERIC Educational Resources Information Center

    Davison, Mark L.; Davenport, Ernest C., Jr.; Chang, Yu-Feng; Vue, Kory; Su, Shiyang

    2015-01-01

    Criterion-related profile analysis (CPA) can be used to assess whether subscores of a test or test battery account for more criterion variance than does a single total score. Application of CPA to subscore evaluation is described, compared to alternative procedures, and illustrated using SAT data. Considerations other than validity and reliability…

  5. Reconditioning of Batteries on the International Space Station

    NASA Technical Reports Server (NTRS)

    Hajela, Gyan; Cohen, Fred; Dalton, Penni

    2004-01-01

    Primary source of electric power for the International Space Station (ISS) is the photovoltaic module (PVM). At assembly complete stage, the ISS will be served by 4 PVMs. Each PVM contains two independent power channels such that one failure will result in loss of only one power channel. During early stages of assembly, the ISS is served by only one PVM designated as P6. Solar arrays are used to convert solar flux into electrical power. Nickel hydrogen batteries are used to store electrical power for use during periods when the solar input is not adequate to support channel loads. Batteries are operated per established procedures that ensure that they are maintained within specified temperature limits, charge current is controlled to conform to a specified charge profile, and battery voltages are maintained within specified limits. Both power channels on the PVM P6 have been operating flawlessly since December 2000 with 100 percent power availability. All components, including batteries, are monitored regularly to ensure that they are operating within specified limits and to trend their wear out and age effects. The paper briefly describes the battery trend data. Batteries have started to show some effects of aging and a battery reconditioning procedure is being evaluated at this time. Reconditioning is expected to reduce cell voltage divergence and provide data that can be used to update the state of charge (SOC) computation in the software to account for battery age. During reconditioning, each battery, one at a time, will be discharged per a specified procedure and then returned to a full state of charge. The paper describes the reconditioning procedure and the expected benefits. The reconditioning procedures have been thoroughly coordinated by all affected technical teams and approved by all required boards. The reconditioning is tentatively scheduled for September 2004.

  6. APPROACHES TO ASSESSING THE VALIDITY OF A FUNCTIONAL OBSERVATIONAL BATTERY

    EPA Science Inventory

    With the growing importance of neurobehavioral assessments at the preliminary stage of chemical testing, it is critical that the screening procedures utilized be valid indicators of neurobehavioral dysfunction in addition to being sensitive, specific, and reliable. fforts in this...

  7. A Brief Review of Biodata History, Research, and Applications

    DTIC Science & Technology

    2007-01-01

    scrutiny, via interpretation of the Uniform Guidelines on Employee Selection Procedures ( EEOC , 1978). Pace and Schoenfeldt (1977) point out that...classification test batteries. American Psychologist, 5, 279. Ledvinka, J., & Scarpello, V. G. (1992). Federal regulation of personnel and human resource

  8. Eco Assist Techniques through Real-time Monitoring of BEV Energy Usage Efficiency

    PubMed Central

    Kim, Younsun; Lee, Ingeol; Kang, Sungho

    2015-01-01

    Energy efficiency enhancement has become an increasingly important issue for battery electric vehicles. Even if it can be improved in many ways, the driver’s driving pattern strongly influences the battery energy consumption of a vehicle. In this paper, eco assist techniques to simply implement an energy-efficient driving assistant system are introduced, including eco guide, eco control and eco monitoring methods. The eco guide is provided to control the vehicle speed and accelerator pedal stroke, and eco control is suggested to limit the output power of the battery. For eco monitoring, the eco indicator and eco report are suggested to teach eco-friendly driving habits. The vehicle test, which is done in four ways, consists of federal test procedure (FTP)-75, new european driving cycle (NEDC), city and highway cycles, and visual feedback with audible warnings is provided to attract the driver’s voluntary participation. The vehicle test result shows that the energy usage efficiency can be increased up to 19.41%. PMID:26121611

  9. 15. Photocopy of drawing of battery control trailer from 'Procedures ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Photocopy of drawing of battery control trailer from 'Procedures and Drills for the NIKE Ajax System,' Department of the Army Field Manual, FM-44-80 from Institute for Military History, Carlisle Barracks, Carlisle, PA, 1956 - NIKE Missile Battery PR-79, East Windsor Road south of State Route 101, Foster, Providence County, RI

  10. 10 CFR Appendix Y to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Battery Chargers

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... power (i.e., watts) consumed as the time series integral of the power consumed over a 1-hour test period...) consumed as the time series integral of the power consumed over a 1-hour test period, divided by the period...-maintenance mode and standby mode over time periods defined in the test procedure. b. Active mode is the...

  11. 10 CFR Appendix Y to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Battery Chargers

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... power (i.e., watts) consumed as the time series integral of the power consumed over a 1-hour test period...) consumed as the time series integral of the power consumed over a 1-hour test period, divided by the period...-maintenance mode and standby mode over time periods defined in the test procedure. b. Active mode is the...

  12. Cognitive Function Before and After Left Heart Catheterization.

    PubMed

    Scott, David A; Evered, Lisbeth; Maruff, Paul; MacIsaac, Andrew; Maher, Sarah; Silbert, Brendan S

    2018-03-10

    Hospital procedures have been associated with cognitive change in older patients. This study aimed to document the prevalence of mild cognitive impairment in individuals undergoing left heart catheterization (LHC) before the procedure and the incidence of cognitive decline to 3 months afterwards. We conducted a prospective, observational, clinical investigation of elderly participants undergoing elective LHC. Cognition was assessed using a battery of written tests and a computerized cognitive battery before the LHC and then at 3 months afterwards. The computerized tests were also administered at 24 hours (or discharge) and 7 days after LHC. A control group of 51 community participants was recruited to calculate cognitive decline using the Reliable Change Index. Of 437 participants, mild cognitive impairment was identified in 226 (51.7%) before the procedure. Computerized tests detected an incidence of cognitive decline of 10.0% at 24 hours and 7.5% at 7 days. At 3 months, written tests detected an incidence of cognitive decline of 13.1% and computerized tests detected an incidence of 8.5%. Cognitive decline at 3 months using written tests was associated with increasing age, whereas computerized tests showed cognitive decline was associated with baseline amnestic mild cognitive impairment, diabetes mellitus, and prior coronary stenting. More than half the patients aged >60 years presenting for LHC have mild cognitive impairment. LHC is followed by cognitive decline in 8% to 13% of individuals at 3 months after the procedure. Subtle cognitive decline both before and after LHC is common and may have important clinical implications. URL: www.anzctr.org.au. Unique identifier: ACTRN12607000051448. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  13. Performance and Health Test Procedure for Grid Energy Storage Systems: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baggu, Murali M; Smith, Kandler A; Friedl, Andrew

    A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: Round-trip efficiency, Standby losses, Response time/accuracy, and Useable Energy/ State of Charge at different discharge/charge rates over the system's lifetime. The procedures are divided into Reference Performance Tests, which require the system to be put in a test mode and are to be conducted in intervals, and Real-time Monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS withmore » little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.« less

  14. The Validity of Selection and Classification Procedures for Predicting Job Performance.

    DTIC Science & Technology

    1987-04-01

    lacholual or pulley Issues. They cemmunicate Me resulls of special analyses, Iantrim rp or phses of a teak, ad hasm quick macton werk. Paperm r reviw ...51 I. Alternative Selection Procedures ................. 56 J. Meta-Analyses of Validities ............. 58 K . Meta-Analytic Comparisons of...Aptitude Test Battery GM General Maintenance GS General Science GVN Cognitive Ability HS&T Health, Social and Technology K Motor Coordination KFM

  15. Lead paste recycling based on conversion into battery grade oxides. Electrochemical tests and industrial production of new batteries

    NASA Astrophysics Data System (ADS)

    Fusillo, G.; Rosestolato, D.; Scura, F.; Cattarin, S.; Mattarozzi, L.; Guerriero, P.; Gambirasi, A.; Brianese, N.; Staiti, P.; Guerriero, R.; La Sala, G.

    2018-03-01

    We present the preparation and characterization of pure lead monoxide obtained through recycling of the lead paste recovered from exhausted lead acid batteries. The recycling is based on a hydrometallurgical procedure reported in a STC Patent, that includes simple chemical operations (desulphurisation, leaching, precipitation, filtration) and a final thermal conversion. Materials obtained by treatment at 600 °C consist predominantly of β-PbO. The electrochemical behaviour of Positive Active Mass (PAM) prepared from different materials (or mixtures) is then investigated and compared. An optimized oxide material, obtained by prolonged (8 h) thermal treatment at 600 °C, consists of pure β-PbO and appears suitable for preparation of battery elements, alone or in mixture with a small fraction (10%-30%) of traditional industrial leady oxide. The resulting battery performances are similar to those obtained from pure leady oxide. In comparison with traditional recycling processes, the proposed method guarantees lower energy consumption, limited environmental impact and reduced operating risk for industry workers.

  16. Development and Field Test of the Trial Battery for Project A

    DTIC Science & Technology

    1987-05-01

    cognitive, temperament, biographical data, and vocational interest) were investigated to detect excessive redundancy among the PB measures, especially ...abili- ties. The literature review procedures were described earlier. Almost no literature was available on computerized, especially microprocessor-driven...Lhese questions, and it is acknowledged that research is necessary to obtain answers, especially with micropro- cessor-driven testing methods. Phase 3

  17. An Examination of Shared Variance in Self-Report and Objective Measures of Attention in the Incarcerated Adult Population

    ERIC Educational Resources Information Center

    Asbjornsen, Arve E.; Jones, Lise O.; Munkvold, Linda H.; Obrzut, John E.; Manger, Terje

    2010-01-01

    Objective: The present study was designed to test some assumptions about screening procedures for ADHD in adults. Method: Twenty-eight incarcerated male adults completed a self report scale of attention deficits as a part of an examination of attention and reading skills. Further assessment of attention included a battery of tests that assessed…

  18. Automation of electromagnetic compatability (EMC) test facilities

    NASA Technical Reports Server (NTRS)

    Harrison, C. A.

    1986-01-01

    Efforts to automate electromagnetic compatibility (EMC) test facilities at Marshall Space Flight Center are discussed. The present facility is used to accomplish a battery of nine standard tests (with limited variations) deigned to certify EMC of Shuttle payload equipment. Prior to this project, some EMC tests were partially automated, but others were performed manually. Software was developed to integrate all testing by means of a desk-top computer-controller. Near real-time data reduction and onboard graphics capabilities permit immediate assessment of test results. Provisions for disk storage of test data permit computer production of the test engineer's certification report. Software flexibility permits variation in the tests procedure, the ability to examine more closely those frequency bands which indicate compatibility problems, and the capability to incorporate additional test procedures.

  19. Brief cognitive and behavioral screening in children with new-onset epilepsy: a pilot feasibility trial.

    PubMed

    Triplett, Regina L; Asato, Miya R

    2015-01-01

    Minimal work has used psychometrically robust measures in a systematic fashion to identify and monitor children at risk for cognitive and behavioral comorbidities in current epilepsy care. We piloted a computerized cognitive battery and behavioral questionnaire for children with newly diagnosed epilepsy to determine clinical feasibility and acceptability to parents and patients. We recruited medication-naïve children (ages 8-17 years) with recent-onset seizures and typical developmental history from an outpatient child neurology clinic. Children completed the CNS Vital Signs computerized battery, whereas parents completed the Strengths and Difficulties Questionnaire. Post-test interviews with parents and patients were completed regarding the acceptability of the assessment procedures. Forty-four families were eligible, and 39 agreed to participate (89%). All assessments were completed in less than 45 minutes. Parents rated testing in clinic as convenient and important, expressing strong interest in the cognitive and behavioral impact of epilepsy and medication. Children also rated the testing procedure as acceptable and agreed that they would recommend it to peers. Our brief battery was tolerated and well received by children and their parents. Computerized testing of children along with a parent questionnaire is a psychometrically viable approach that is acceptable to families. Our protocol is time efficient for clinical use with the potential to detect early cognitive and behavioral difficulties related to epilepsy. Ongoing longitudinal study will provide further information regarding the success of our screening methods in monitoring for disease- or treatment-related changes. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. 40 CFR 86.1721-99 - Application for certification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... which the vehicle is certifying: LDV, LDT 0-3750 lbs LVW, LDT 3751-5750 lbs LVW (state test weight range... of the propulsion system for the vehicle. (4) Identification and description of the climate control... state-of-charge, battery charging capacity and recharging procedures, and any other relevant information...

  1. 40 CFR 86.1721-99 - Application for certification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... which the vehicle is certifying: LDV, LDT 0-3750 lbs LVW, LDT 3751-5750 lbs LVW (state test weight range... of the propulsion system for the vehicle. (4) Identification and description of the climate control... state-of-charge, battery charging capacity and recharging procedures, and any other relevant information...

  2. 40 CFR 86.1721-99 - Application for certification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... which the vehicle is certifying: LDV, LDT 0-3750 lbs LVW, LDT 3751-5750 lbs LVW (state test weight range... of the propulsion system for the vehicle. (4) Identification and description of the climate control... state-of-charge, battery charging capacity and recharging procedures, and any other relevant information...

  3. Refinement of Scoring Procedures for the Basic Attributes Test (BAT) Battery

    DTIC Science & Technology

    1993-03-01

    see Carretta, 1991). Research on the BAT summary scores has shown that some of them (a) are significantly positively skewed and platykurtic , (b) contain...for positively skewed and platykurtic data distributions, and those that were applied here to the BAT data, are the square-root and natural logarithm

  4. Performance of Li-Ion Cells Under Battery Voltage Charge Control

    NASA Technical Reports Server (NTRS)

    Rao, Gopalakrishna M.; Vaidyanathan, Hari; Day, John H. (Technical Monitor)

    2001-01-01

    A study consisting of electrochemical characterization and Low-Earth-Orbit (LEO) cycling of Li-Ion cells from three vendors was initiated in 1999 to determine the cycling performance and to infuse the new technology in the future NASA missions. The 8-cell batteries included in this evaluation are prismatic cells manufactured by Mine Safety Appliances Company (MSA), cylindrical cells manufactured by SAFT and prismatic cells manufactured by Yardney Technical Products, Inc. (YTP). The three batteries were cycle tested in the LEO regime at 40% depth of discharge, and under a charge control technique that consists of battery voltage clamp with a current taper. The initial testing was conducted at 20 C; however, the batteries were cycled also intermittently at low temperatures. YTP 20 Ah cells consisted of mixed-oxide (Co and Ni) positive, graphitic carbon negative, LIPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was 32 V. The low temperature cycling tests started after 4575 cycles at 20 C. The cells were not capable of cycling. at low temperature since the charge acceptance at battery level was poor. There was a cell in the battery that showed too high an end-of-charge (EOC) voltage thereby limiting the ability to charge the rest of the cells in the battery. The battery has completed 6714 cycles. SAFT 12 Ah cells consisted of mixed-oxide (Co and NO positive, graphitic carbon negative, LiPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was for 30.8 V. The low temperature cycling tests started after 4594 cycles at 20 C. A cell that showed low end of discharge (EOD) and EOC voltages and three other cells that showed higher EOC voltages limited the charge acceptance at the selected voltage limit during charge. The cells were capable of cycling at 10 C and 0 C but the charge voltage limit had to be increased to 34.3 V (4.3 V per cell). The low temperature cycling may have induced poor chargeability since the voltage had to be increased to achieve the required charge input. The battery has completed 6226 cycles. MSA 10 Ah cells consisted of Co oxide positive, graphitic carbon negative, LiPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was 30.8 V. The low temperature cycling tests were started after 2182 cycles at 20 C. The cells were capable of cycling at 10 C and 0 C. Like SAFT, the voltage limit on charge had to be increased to 36 V (4.5 V per cell). There was a cell (cell S/N 13) in the battery that showed poor performance features such as low EOD voltage and high EOC voltage. The battery has completed 3441 cycles. A reconditioning procedure that consisted of C15 charge to a taper current of C/100 and C/20 discharge improved the voltage behavior of SAFT and MSA cells with no significant effect on YTP cells. We have demonstrated that the charge operation with VT clamp at battery rather than at cell level is feasible for onboard Li-Ion battery operation.

  5. A standardized test battery for the study of synesthesia

    PubMed Central

    Eagleman, David M.; Kagan, Arielle D.; Nelson, Stephanie S.; Sagaram, Deepak; Sarma, Anand K.

    2014-01-01

    Synesthesia is an unusual condition in which stimulation of one modality evokes sensation or experience in another modality. Although discussed in the literature well over a century ago, synesthesia slipped out of the scientific spotlight for decades because of the difficulty in verifying and quantifying private perceptual experiences. In recent years, the study of synesthesia has enjoyed a renaissance due to the introduction of tests that demonstrate the reality of the condition, its automatic and involuntary nature, and its measurable perceptual consequences. However, while several research groups now study synesthesia, there is no single protocol for comparing, contrasting and pooling synesthetic subjects across these groups. There is no standard battery of tests, no quantifiable scoring system, and no standard phrasing of questions. Additionally, the tests that exist offer no means for data comparison. To remedy this deficit we have devised the Synesthesia Battery. This unified collection of tests is freely accessible online (http://www.synesthete.org). It consists of a questionnaire and several online software programs, and test results are immediately available for use by synesthetes and invited researchers. Performance on the tests is quantified with a standard scoring system. We introduce several novel tests here, and offer the software for running the tests. By presenting standardized procedures for testing and comparing subjects, this endeavor hopes to speed scientific progress in synesthesia research. PMID:16919755

  6. Fast charging nickel-metal hydride traction batteries

    NASA Astrophysics Data System (ADS)

    Yang, Xiao Guang; Liaw, Bor Yann

    This paper describes the fast charge ability, or "fast rechargeability", of nominal 85 Ah Ni-MH modules under various fast charge conditions, including constant current (CC); typically 1-3C, and constant power (CP) regimes. Our tests revealed that there is no apparent difference between CC and CP fast charge regimes with respect to charge efficiency and time. Following the USABC Electric Vehicle Battery Test Procedures Manual (Revision 2, 1996), we demonstrated that we were able to return 40% state of charge (SOC) from 60% depth of discharge (DOD) to 20% DOD within 15 min. Most importantly, we found that the internal pressure of the cell is the most critical parameter in the control of the fast charge process and the safe operation of the modules.

  7. Energy Systems Test Area (ESTA). Power Systems Test Facilities

    NASA Technical Reports Server (NTRS)

    Situ, Cindy H.

    2010-01-01

    This viewgraph presentation provides a detailed description of the Johnson Space Center's Power Systems Facility located in the Energy Systems Test Area (ESTA). Facilities and the resources used to support power and battery systems testing are also shown. The contents include: 1) Power Testing; 2) Power Test Equipment Capabilities Summary; 3) Source/Load; 4) Battery Facilities; 5) Battery Test Equipment Capabilities Summary; 6) Battery Testing; 7) Performance Test Equipment; 8) Battery Test Environments; 9) Battery Abuse Chambers; 10) Battery Abuse Capabilities; and 11) Battery Test Area Resources.

  8. Photovoltaic performance and reliability workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroposki, B

    1996-10-01

    This proceedings is the compilation of papers presented at the ninth PV Performance and Reliability Workshop held at the Sheraton Denver West Hotel on September 4--6, 1996. This years workshop included presentations from 25 speakers and had over 100 attendees. All of the presentations that were given are included in this proceedings. Topics of the papers included: defining service lifetime and developing models for PV module lifetime; examining and determining failure and degradation mechanisms in PV modules; combining IEEE/IEC/UL testing procedures; AC module performance and reliability testing; inverter reliability/qualification testing; standardization of utility interconnect requirements for PV systems; need activitiesmore » to separate variables by testing individual components of PV systems (e.g. cells, modules, batteries, inverters,charge controllers) for individual reliability and then test them in actual system configurations; more results reported from field experience on modules, inverters, batteries, and charge controllers from field deployed PV systems; and system certification and standardized testing for stand-alone and grid-tied systems.« less

  9. Hot Swapping Protocol Implementations in the OPNET Modeler Development Environment

    DTIC Science & Technology

    2008-03-01

    components. Unfortunately, this style is not efficient or particularly human–readable. Even purely pedagogical scenarios consisting of a client and a...definition provided by the mock object. sion of this kernel procedure steers all packets sent with op pk deliver() to the unit testing’s specialized...forms of development. Moreover, batteries of unit tests could ship with the accompanying process models and serve as robust regression tests

  10. Battery Separator Characterization and Evaluation Procedures for NASA's Advanced Lithium-Ion Batteries

    NASA Technical Reports Server (NTRS)

    Baldwin, Richard S.; Bennet, William R.; Wong, Eunice K.; Lewton, MaryBeth R.; Harris, Megan K.

    2010-01-01

    To address the future performance and safety requirements for the electrical energy storage technologies that will enhance and enable future NASA manned aerospace missions, advanced rechargeable, lithium-ion battery technology development is being pursued within the scope of the NASA Exploration Technology Development Program s (ETDP's) Energy Storage Project. A critical cell-level component of a lithium-ion battery which significantly impacts both overall electrochemical performance and safety is the porous separator that is sandwiched between the two active cell electrodes. To support the selection of the optimal cell separator material(s) for the advanced battery technology and chemistries under development, laboratory characterization and screening procedures were established to assess and compare separator material-level attributes and associated separator performance characteristics.

  11. 40 CFR 52.2220 - Identification of plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Coke Battery Underfire (combustion) Stacks 06/07/92 08/15/97, 62 FR 43643 CHAPTER 1200-3-6NON-PROCESS... Destruction or Removal Efficiency and Monitoring Requirements 05/18/93 02/27/95, 60 FR 10504 Section 1200-3-18-.84 Test Methods and Compliance Procedures: Determining the Destruction or Removal Efficiency of a...

  12. 40 CFR 63.310 - Requirements for startups, shutdowns, and malfunctions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... plan, the owner or operator may use the standard operating procedures manual for the battery, provided... startup, shutdown, and malfunction plan that describes procedures for operating the battery, including... (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE...

  13. 40 CFR 63.310 - Requirements for startups, shutdowns, and malfunctions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... plan, the owner or operator may use the standard operating procedures manual for the battery, provided... startup, shutdown, and malfunction plan that describes procedures for operating the battery, including... (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE...

  14. 40 CFR 63.310 - Requirements for startups, shutdowns, and malfunctions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... plan, the owner or operator may use the standard operating procedures manual for the battery, provided... startup, shutdown, and malfunction plan that describes procedures for operating the battery, including... (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE...

  15. 40 CFR 63.310 - Requirements for startups, shutdowns, and malfunctions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... plan, the owner or operator may use the standard operating procedures manual for the battery, provided... startup, shutdown, and malfunction plan that describes procedures for operating the battery, including... (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE...

  16. The auditory cross-section (AXS) test battery: A new way to study afferent/efferent relations linking body periphery (ear, voice, heart) with brainstem and cortex

    NASA Astrophysics Data System (ADS)

    Lauter, Judith

    2002-05-01

    Several noninvasive methods are available for studying the neural bases of human sensory-motor function, but their cost is prohibitive for many researchers and clinicians. The auditory cross section (AXS) test battery utilizes relatively inexpensive methods, yet yields data that are at least equivalent, if not superior in some applications, to those generated by more expensive technologies. The acronym emphasizes access to axes-the battery makes it possible to assess dynamic physiological relations along all three body-brain axes: rostro-caudal (afferent/efferent), dorso-ventral, and right-left, on an individually-specific basis, extending from cortex to the periphery. For auditory studies, a three-level physiological ear-to-cortex profile is generated, utilizing (1) quantitative electroencephalography (qEEG); (2) the repeated evoked potentials version of the auditory brainstem response (REPs/ABR); and (3) otoacoustic emissions (OAEs). Battery procedures will be explained, and sample data presented illustrating correlated multilevel changes in ear, voice, heart, brainstem, and cortex in response to circadian rhythms, and challenges with substances such as antihistamines and Ritalin. Potential applications for the battery include studies of central auditory processing, reading problems, hyperactivity, neural bases of voice and speech motor control, neurocardiology, individually-specific responses to medications, and the physiological bases of tinnitus, hyperacusis, and related treatments.

  17. Sequential Tests of Multiple Hypotheses Controlling Type I and II Familywise Error Rates

    PubMed Central

    Bartroff, Jay; Song, Jinlin

    2014-01-01

    This paper addresses the following general scenario: A scientist wishes to perform a battery of experiments, each generating a sequential stream of data, to investigate some phenomenon. The scientist would like to control the overall error rate in order to draw statistically-valid conclusions from each experiment, while being as efficient as possible. The between-stream data may differ in distribution and dimension but also may be highly correlated, even duplicated exactly in some cases. Treating each experiment as a hypothesis test and adopting the familywise error rate (FWER) metric, we give a procedure that sequentially tests each hypothesis while controlling both the type I and II FWERs regardless of the between-stream correlation, and only requires arbitrary sequential test statistics that control the error rates for a given stream in isolation. The proposed procedure, which we call the sequential Holm procedure because of its inspiration from Holm’s (1979) seminal fixed-sample procedure, shows simultaneous savings in expected sample size and less conservative error control relative to fixed sample, sequential Bonferroni, and other recently proposed sequential procedures in a simulation study. PMID:25092948

  18. USABC Development of 12 Volt Battery for Start-Stop Application: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tataria, H.; Gross, O.; Bae, C.

    Global automakers are accelerating the development of fuel efficient vehicles, as a part of meeting regional regulatory CO2 emissions requirements. The micro hybrid vehicles with auto start-stop functionality are considered economical solutions for the stringent European regulations. Flooded lead acid batteries were initially considered the most economical solution for idle-stop systems. However, the dynamic charge acceptance (DCA) at lower state-of-charge (SOC) was limiting the life of the batteries. While improved lead-acid batteries with AGM and VRLA features have improved battery longevity, they do not last the life of the vehicle. The United States Advanced Battery Consortium (or USABC, a consortiummore » of GM, Ford, and Chrysler) analyzed energy storage needs for a micro hybrid automobile with start-stop capability, and with a single power source. USABC has analyzed the start-stop behaviors of many drivers and has developed the requirements for the start-stop batteries (Table 3). The testing procedures to validate the performance and longevity were standardized and published. The guideline for the cost estimates calculations have also been provided, in order to determine the value of the newly developed modules. The analysis effort resulted in a set of requirements which will help the battery manufacturers to develop a module to meet the automotive Original Equipment Manufacturers (OEM) micro hybrid vehicle requirements. Battery developers were invited to submit development proposals and two proposals were selected for 50% cost share with USABC/DOE.« less

  19. Fabrication of VB2/Air Cells for Electrochemical Testing

    PubMed Central

    Stuart, Jessica; Lopez, Ruben; Lau, Jason; Li, Xuguang; Waje, Mahesh; Mullings, Matthew; Rhodes, Christopher; Licht, Stuart

    2013-01-01

    A technique to investigate the properties and performance of new multi-electron metal/air battery systems is proposed and presented. A method for synthesizing nanoscopic VB2 is presented as well as step-by-step procedure for applying a zirconium oxide coating to the VB2 particles for stabilization upon discharge. The process for disassembling existing zinc/air cells is shown, in addition construction of the new working electrode to replace the conventional zinc/air cell anode with a the nanoscopic VB2 anode. Finally, discharge of the completed VB2/air battery is reported. We show that using the zinc/air cell as a test bed is useful to provide a consistent configuration to study the performance of the high-energy high capacity nanoscopic VB2 anode. PMID:23962835

  20. Toward Objectivity in Diagnosing Learning Disabilities: Refinement of Established Procedures.

    ERIC Educational Resources Information Center

    Goodman, Marvin; Mina, Elias

    Variability in diagnostic procedures and a lack of valid and reliable measures led to the development of a comprehensive battery, which incorporated an operational definition of learning disabilities. The battery consisted of forms for observing these functions: intelligence, academic achievement, gross and fine motor control, visual perception,…

  1. State of charge estimation in Ni-MH rechargeable batteries

    NASA Astrophysics Data System (ADS)

    Milocco, R. H.; Castro, B. E.

    In this work we estimate the state of charge (SOC) of Ni-MH rechargeable batteries using the Kalman filter based on a simplified electrochemical model. First, we derive the complete electrochemical model of the battery which includes diffusional processes and kinetic reactions in both Ni and MH electrodes. The full model is further reduced in a cascade of two parts, a linear time invariant dynamical sub-model followed by a static nonlinearity. Both parts are identified using the current and potential measured at the terminals of the battery with a simple 1-D minimization procedure. The inverse of the static nonlinearity together with a Kalman filter provide the SOC estimation as a linear estimation problem. Experimental results with commercial batteries are provided to illustrate the estimation procedure and to show the performance.

  2. Hubble Space Telescope nickel-hydrogen battery testing: An update

    NASA Technical Reports Server (NTRS)

    Whitt, Thomas H.; Brewer, Jeffrey C.

    1995-01-01

    The Marshall Space Flight Center (MSFC) began testing the HST Ni-H2 Six Battery Test and the 'Flight Spare Battery' Tests approximately one year before the launch of the HST. These tests are operated and reported on by the MSFC, but are managed and funded by Goddard Space Flight Center in direct support of the HST program. The HST Ni-H2 batteries are built from Eagle Picher RNH-90-3 cells. The HST EPS (electrical power system) is a direct energy transfer power system. The HST Ni-H2 Six Battery Test is a breadboard of the HST EPS. The batteries in the test are composed of test module cells and packaged into three battery modules identical to the flight modules. This test is the HST EPS testbed. The 'Flight Spare Battery' Test is a simulation of one of the six battery channels on the HST. The cells in the test are from the flight spare lot of cells, which are the same lot of cells that three of the six HST flight batteries are made from. This test is the battery life test for the HST program.

  3. Long-term Expectations of Vagus Nerve Stimulation: A Look at Battery Replacement and Revision Surgery.

    PubMed

    Couch, Jonathan D; Gilman, Arthur M; Doyle, Werner K

    2016-01-01

    Vagus nerve stimulation (VNS) is an established surgical treatment for medically intractable epilepsy with more than 75 000 devices implanted worldwide. While there are many reports documenting efficacy, complications, and clinical use, there are very few reports concerning VNS battery replacement and revision surgeries. To review our experience with VNS battery replacement and revision surgery. We retrospectively reviewed 1144 consecutive VNS procedures performed by a single surgeon between 1998 and 2012. Six hundred forty-four of those procedures were the initial placement of the VNS device. These patients were then followed to determine when a battery change occurred and what type of revision or removal was necessary. In the study, 46% of patients required at least 1 or more type of battery replacement or revision surgery. The most common types of surgery were for generator battery depletion (27%), poor efficacy (9%), and lead malfunction (8%). Only 2% of patients were noted to have an infection. VNS battery replacement, revisions, and removals account for almost one-half of all VNS procedures. Our findings suggest important long-term expectations for VNS including expected complications, battery life, and other surgical issues. Review of the literature suggests that this is the first large review of VNS revisions by a single center. Our findings are important to better characterize long-term surgical expectations of VNS therapy. A significant portion of patients undergoing VNS therapy will eventually require revision.

  4. Expanding Talent Search Procedures by Including Measures of Spatial Ability: CTY's Spatial Test Battery

    ERIC Educational Resources Information Center

    Stumpf, Heinrich; Mills, Carol J.; Brody, Linda E.; Baxley, Philip G.

    2013-01-01

    The importance of spatial ability for success in a variety of domains, particularly in science, technology, engineering, and mathematics (STEM), is widely acknowledged. Yet, students with high spatial ability are rarely identified, as Talent Searches for academically talented students focus on identifying high mathematical and verbal abilities.…

  5. Analysis of Large Data Sets in Brazil: A Study on Selection Procedures to College Admission.

    ERIC Educational Resources Information Center

    Rodrigues, Aroldo

    Because the achievement battery traditionally administered to Brazilian college bound students may discriminate against those who cannot afford to attend the best high schools or preparatory courses, tests were developed to measure aptitude for higher education, independent of ability or actual knowledge of course content. The focus of the…

  6. CBT for Nightmares in OEF/OIF Veterans

    DTIC Science & Technology

    2013-07-01

    Freedom (OIF) have significant psychological symptoms related to traumatic war zone exposure, including recurrent nightmares and other sleep disturbances...nightmares. Participants complete a battery of computerized neuropsychological tests at baseline and are stratified in their randomization to either...procedures were developed. Study supervisors, Drs. Philip Gehrman and Andrea Phelps , review treatment tapes, and weekly supervision calls with study

  7. Development and Validation of a Computer Interactive Test Battery.

    ERIC Educational Resources Information Center

    Sheppard, Valarie A.; Baker, Todd A.; Gebhardt, Deborah L.; Leonard, Kristine M.

    The purpose of this project was to develop valid evaluation procedures for the selection of Container Equipment Operators (CEOs) in the shipping industry. A job analysis was conducted to identify the essential tasks of the CEO job. Site visits, a task inventory, and the determination of essential tasks were used in the job analysis. The skills and…

  8. [Surgical treatment of normal pressure hydrocephalus].

    PubMed

    Svendsen, F; Hugdahl, K; Wester, K

    2001-05-30

    Normal pressure hydrocephalus (NPH) is an important diagnosis to keep in mind, i.e. the possibility that NPH and not a neurodegenerative disease causes the patient's symptoms with ataxia, urinary incontinence and dementia. Clinical improvement, sometimes a complete reversal of the symptoms, may be seen after a simple surgical procedure. This prospective study was performed by testing eight consecutively shunted patients with a walking test and a cognitive test battery pre- and postoperatively. Improvement 3-4 months after the shunting procedure suggests that NPH was present in six of eight patients. Walking ability was improved after surgery, also in patients with severe dementia. Severe dementia caused by NPH is hardly reversible, though cognitive tests may indicate some improvement. However, early surgical treatment of NPH in patients not suffering from a dementia according to the Mini Mental Status Test may bring improvement in some cognitive functions. Patients with both clinical and radiological signs of normal pressure hydrocephalus should be offered a shunting procedure.

  9. Free and Cued Selective Reminding Identifies Very Mild Dementia in Primary Care

    PubMed Central

    Grober, Ellen; Sanders, Amy E.; Hall, Charles; Lipton, Richard B.

    2010-01-01

    The Free and Cued Selective Reminding Test (FCSRT) is used widely to identify very mild dementia; three alternative scoring procedures have been proposed based on free recall, total recall, and cue efficiency. We compared the predictive validity of these scoring procedures for the identification of very mild prevalent dementia (CDR=0.5), of incident dementia and for distinguishing AD and nonAD dementias. We tested 244 elderly African American and Caucasian primary care patients at 18 month intervals using a screening neuropsychological battery that included the FCSRT and a comprehensive diagnostic neuropsychological battery. Median follow-up was 2.6 years. Dementia diagnoses were assigned using standard criteria without access to the results of the screening battery. There were 50 prevalent and 28 incident dementia cases. At scores selected to provide specificities of 90%, free recall was more sensitive to incident and prevalent dementia than the other two measures. Patients with impaired free recall were 15 times more likely to have a prevalent dementia and their risk of future dementia was four times higher than patients with intact free recall. Neither race nor education affected prediction though older patients were at increased risk of future dementia. Total recall was more impaired in AD dementia than in nonAD dementias. The results indicate that using the FCSRT, free recall is best measure for detecting prevalent dementia and predicting future dementia. Total recall impairment supports the diagnosis of AD rather than nonAD dementia. PMID:20683186

  10. HIL Development and Validation of Lithium-ion Battery Packs (SAE 2014-01-1863)

    EPA Science Inventory

    A Battery Test Facility (BTF) has been constructed at United States Environmental Protection Agency (EPA) to test various automotive battery packs for HEV, PHEV, and EV vehicles. Battery pack tests were performed in the BTF using a battery cycler, testing controllers, battery pa...

  11. 3. Photocopy of photograph showing acquisition radar from 'Procedures and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Photocopy of photograph showing acquisition radar from 'Procedures and Drills for the NIKE Hercules Missile Battery,' Department of the Army Field Manual, FM-44-82 from Institute for Military History, Carlisle Barracks, Carlisle, PA, 1959 - NIKE Missile Battery PR-79, East Windsor Road south of State Route 101, Foster, Providence County, RI

  12. Battery Reinitialization of the Photovoltaic Module of the International Space Station

    NASA Technical Reports Server (NTRS)

    Hajela, Gyan; Cohen, Fred; Dalton, Penni

    2002-01-01

    The photovoltaic (PV) module on the International Space Station (ISS) has been operating since November 2000 and supporting electric power demands of the ISS and its crew of three. The PV module contains photovoltaic arrays that convert solar energy to electrical power and an integrated equipment assembly (IEA) that houses electrical hardware and batteries for electric power regulation and storage. Each PV module contains two independent power channels for fault tolerance. Each power channel contains three batteries in parallel to meet its performance requirements and for fault tolerance. Each battery consists of 76 Ni-Hydrogen (Ni-H2) cells in series. These 76 cells are contained in two orbital replaceable units (ORU) that are connected in series. On-orbit data are monitored and trended to ensure that all hardware is operating normally. Review of on-orbit data showed that while five batteries are operating very well, one is showing signs of mismatched ORUs. The cell pressure in the two ORUs differs by an amount that exceeds the recommended range. The reason for this abnormal behavior may be that the two ORUs have different use history. An assessment was performed and it was determined that capacity of this battery would be limited by the lower pressure ORU. Steps are being taken to reduce this pressure differential before battery capacity drops to the point of affecting its ability to meet performance requirements. As a first step, a battery reinitialization procedure was developed to reduce this pressure differential. The procedure was successfully carried out on-orbit and the pressure differential was reduced to the recommended range. This paper describes the battery performance and the consequences of mismatched ORUs that make a battery. The paper also describes the reinitialization procedure, how it was performed on orbit, and battery performance after the reinitialization. On-orbit data monitoring and trending is an ongoing activity and it will continue as ISS assembly progresses.

  13. Marshall Space Flight Center battery activity

    NASA Technical Reports Server (NTRS)

    Lowery, Eric

    1993-01-01

    The topics covered are presented in viewgraph form and include a flight program history and in-house activities. Some of the in-house activities addressed include secondary battery/cell testing and Hubble Space Telescope Test data updates involving the NiCd type 40 test - battery 1 and 2, the NiCd type 41 test battery, the general electric battery, the NiCd six-battery system, the six four-cell packs, fourteen-cell pack, three four-cell packs, the NiH2 six-battery system, and the flight spare battery. A general test data update is also presented for the twelve-cell pack, the four four-cell packs, the reconditioning test, and planned Ni-MH testing.

  14. Use of COTS Batteries on ISS and Shuttle

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.

    2004-01-01

    This presentation focuses on COTS Battery testing for energy content, toxicity, hazards, failures modes and controls for different battery chemistries. It also discusses the current program requirements, challenges with COTS Batteries in manned vehicle COTS methodology, JSC test details, and gives a list of incidents from consumer protection safety commissions. The Battery test process involved testing new batteries for engineering certification, qualification of batteries, flight acceptance, cell and battery, environment, performance and abuse. Their conclusions and recommendations were that: high risk is undertaken with the use of COTS batteries, hazard control verification is required to allow the use of these batteries on manned space flights, failures during use cannot be understood if different scenarios of failure are not tested on the ground, and that testing is performed on small sample numbers due to restrictions on cost and time. They recommend testing of large sample size to gain more confidence in the operation of the hazard controls.

  15. Development of Officer Selection Battery Forms 3 and 4

    DTIC Science & Technology

    1986-03-01

    the development, standardization, and validation of two parallel forms of a test to be used for assessing young men and women applying to ROTC. Fairly...appropriate di6ffculty, high reliability, and state-of-the-art validity and fairness for mit~orities and women . EDGAR M. JOHNSON Technical Directcr 4v 4...administrable, test for use in assessing young men and women applying to Advanced Army ROTC. Procedur .-: Earlier research had performed an analysis of the

  16. Upgraded demonstration vehicle task report

    NASA Technical Reports Server (NTRS)

    Bryant, J.; Hardy, K.; Livingston, R.; Sandberg, J.

    1981-01-01

    Vehicle/battery performance capabilities and interface problems that occurred when upgraded developmental batteries were integrated with upgraded versions of comercially available electric vehicles were investigated. Developmental batteries used included nickel zinc batteries, a nickel iron battery, and an improved lead acid battery. Testing of the electric vehicles and upgraded batteries was performed in the complete vehicle system environment to characterize performance and identify problems unique to the vehicle/battery system. Constant speed tests and driving schedule range tests were performed on a chassis dynamometer. The results from these tests of the upgraded batteries and vehicles were compared to performance capabilities for the same vehicles equipped with standard batteries.

  17. Program maintenance manual for nickel cadmium battery expert system, version 1

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The Nickel-Cadmium Battery Expert System (NICBES) is an expert system for fault diagnosis and advice of the nickel-cadmium batteries found in the Hubble Space Telescope (HST). The system application and security, equipment environment, and the program maintenance procedures are examined.

  18. 5. Photocopy of photograph showing target tracking radar from 'Procedures ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Photocopy of photograph showing target tracking radar from 'Procedures and Drills for the NIKE Hercules Missile Battery,' Department of the Army Field Manual, FM-44-82 from Institute for Military History, Carlisle Barracks, Carlisle, PA, 1959 - NIKE Missile Battery PR-79, East Windsor Road south of State Route 101, Foster, Providence County, RI

  19. An Investigation of an Evaluation Method and Retraining Procedures for Emotionally Handicapped Children with Cognitive-Motor Deficits. Final Report.

    ERIC Educational Resources Information Center

    Rubin, Eli Z.; And Others

    To assess the effects of specialized retraining of cognitive, perceptual, and motor (CPM) deficits, a battery of tests was prepared and used with 200 behaviorally maladjusted and 200 problem-free children. The composite score indicated that 40% of the maladjusted group manifested major dysfunction whereas none of the problem-free group…

  20. CBT for Nightmares in OEF/OIF Veterans

    DTIC Science & Technology

    2012-07-01

    OEF) and Operation Iraqi Freedom ( OIF) have significant psychological symptoms related to traumatic war zone exposure, includi ng recurrent...and assessed for PTSD and war zone-related nightmares. Participants complete a battery of computerized neuropsychological tests at baseline and are...rating procedures were developed, and these are being used. Study supervisors, Drs. Philip Gehrm an and Andrea Phelps , review treatment tapes, and

  1. Ground Handling of Batteries at Test and Launch-site Facilities

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.; Hohl, Alan R.

    2008-01-01

    Ground handling of flight as well as engineering batteries at test facilities and launch-site facilities is a safety critical process. Test equipment interfacing with the batteries should have the required controls to prevent a hazardous failure of the batteries. Test equipment failures should not induce catastrophic failures on the batteries. Transportation requirements for batteries should also be taken into consideration for safe transportation. This viewgraph presentation includes information on the safe handling of batteries for ground processing at test facilities as well as launch-site facilities.

  2. Design Evaluation of High Reliability Lithium Batteries

    NASA Technical Reports Server (NTRS)

    Buchman, R. C.; Helgeson, W. D.; Istephanous, N. S.

    1985-01-01

    Within one year, a lithium battery design can be qualified for device use through the application of accelerated discharge testing, calorimetry measurements, real time tests and other supplemental testing. Materials and corrosion testing verify that the battery components remain functional during expected battery life. By combining these various methods, a high reliability lithium battery can be manufactured for applications which require zero defect battery performance.

  3. NASA/Marshall's lithium battery applications

    NASA Technical Reports Server (NTRS)

    Paschal, L. E.

    1980-01-01

    A general lithium battery is described and a summary of lithium battery applications is presented. Four aspects of a particular lithium battery, the inducement environmental contamination monitoring battery, are discussed-design and construction details, thermal vacuum tests, projection tests, and acceptance tests.

  4. International Ultraviolet Explorer (IUE) Battery History and Performance

    NASA Technical Reports Server (NTRS)

    Rao, Gopalskrishna M.; Tiller, Smith E.

    1999-01-01

    The "International Ultraviolet Explorer (IUE) Battery History and Performance" report provides the information on the cell/battery design, battery performance during the thirty eight (38) solar eclipse seasons and the end-of-life test data. It is noteworthy that IUE spacecraft was an in-house project and that the batteries were designed, fabricated and tested (Qualification and Acceptance) at the Goddard Space Flight Center. A detailed information is given on the cell and battery design criteria and the designs, on the Qualification and the Acceptance tests, and on the cell life cycling tests. The environmental, thermal, and vibration tests were performed on the batteries at the battery level as well as with the interface on the spacecraft. The telemetry data were acquired, analyzed, and trended for various parameters over the mission life. Rigorous and diligent battery management programs were developed and implemented from time to time to extend the mission life over eighteen plus years. Prior to the termination of spacecraft operation, special tests were conducted to check the battery switching operation, battery residual capacity, third electrode performance and battery impedance.

  5. The 2004 NASA Aerospace Battery Workshop

    NASA Technical Reports Server (NTRS)

    2006-01-01

    Topics covered include: Super NiCd(TradeMark) Energy Storage for Gravity Probe-B Relativity Mission; Hubble Space Telescope 2004 Battery Update; The Development of Hermetically Sealed Aerospace Nickel-Metal Hydride Cell; Serial Charging Test on High Capacity Li-Ion Cells for the Orbiter Advanced Hydraulic Power System; Cell Equalization of Lithium-Ion Cells; The Long-Term Performance of Small-Cell Batteries Without Cell-Balancing Electronics; Identification and Treatment of Lithium Battery Cell Imbalance under Flight Conditions; Battery Control Boards for Li-Ion Batteries on Mars Exploration Rovers; Cell Over Voltage Protection and Balancing Circuit of the Lithium-Ion Battery; Lithium-Ion Battery Electronics for Aerospace Applications; Lithium-Ion Cell Charge Control Unit; Lithium Ion Battery Cell Bypass Circuit Test Results at the U.S. Naval Research Laboratory; High Capacity Battery Cell By-Pass Switches: High Current Pulse Testing of Lithium-Ion; Battery By-Pass Switches to Verify Their Ability to Withstand Short-Circuits; Incorporation of Physics-Based, Spatially-Resolved Battery Models into System Simulations; A Monte Carlo Model for Li-Ion Battery Life Projections; Thermal Behavior of Large Lithium-Ion Cells; Thermal Imaging of Aerospace Battery Cells; High Rate Designed 50 Ah Li-Ion Cell for LEO Applications; Evaluation of Corrosion Behavior in Aerospace Lithium-Ion Cells; Performance of AEA 80 Ah Battery Under GEO Profile; LEO Li-Ion Battery Testing; A Review of the Feasibility Investigation of Commercial Laminated Lithium-Ion Polymer Cells for Space Applications; Lithium-Ion Verification Test Program; Panasonic Small Cell Testing for AHPS; Lithium-Ion Small Cell Battery Shorting Study; Low-Earth-Orbit and Geosynchronous-Earth-Orbit Testing of 80 Ah Batteries under Real-Time Profiles; Update on Development of Lithium-Ion Cells for Space Applications at JAXA; Foreign Comparative Technology: Launch Vehicle Battery Cell Testing; 20V, 40 Ah Lithium Ion Polymer Battery for the Spacesuit; Low Temperature Life-Cycle Testing of a Lithium-Ion Battery for Low-Earth-Orbiting Spacecraft; and Evaluation of the Effects of DoD and Charge Rate on a LEO Optimized 50 Ah Li-Ion Aerospace Cell.

  6. 75 FR 61655 - Airworthiness Directives; Piper Aircraft, Inc. Model PA-28-161 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-06

    ... (FADEC) backup battery, replacing the supplement pilot's operating handbook and FAA approved airplane... can allow the FADEC to shut down or reset if the main battery is depleted and the electrical charging... service information describes procedures for installation of a FADEC backup battery. FAA's Determination...

  7. Progress towards computer simulation of NiH2 battery performance over life

    NASA Technical Reports Server (NTRS)

    Zimmerman, Albert H.; Quinzio, M. V.

    1995-01-01

    The long-term performance of rechargeable battery cells has traditionally been verified through life-testing, a procedure that generally requires significant commitments of funding and test resources. In the situation of nickel hydrogen battery cells, which have the capability of providing extremely long cycle life, the time and cost required to conduct even accelerated testing has become a serious impediment to transitioning technology improvements into spacecraft applications. The utilization of computer simulations to indicate the changes in performance to be expected in response to design or operating changes in nickel hydrogen cells is therefore a particularly attractive tool in advanced battery development, as well as for verifying performance in different applications. Computer-based simulations of the long-term performance of rechargeable battery cells have typically had very limited success in the past. There are a number of reasons for the lack in progress in this area. First, and probably most important, all battery cells are relatively complex electrochemical systems, in which performance is dictated by a large number of interacting physical and chemical processes. While the complexity alone is a significant part of the problem, in many instances the fundamental chemical and physical processes underlying long-term degradation and its effects on performance have not even been understood. Second, while specific chemical and physical changes within cell components have been associated with degradation, there has been no generalized simulation architecture that enables the chemical and physical structure (and changes therein) to be translated into cell performance. For the nickel hydrogen battery cell, our knowledge of the underlying reactions that control the performance of this cell has progressed to where it clearly is possible to model them. The recent development of a relative generalized cell modelling approach provides the framework for translating the chemical and physical structure of the components inside a cell into its performance characteristics over its entire cycle life. This report describes our approach to this task in terms of defining those processes deemed critical in controlling performance over life, and the model architecture required to translate the fundamental cell processes into performance profiles.

  8. [Fall 2015 Abstract by Stephanie Scharf

    NASA Technical Reports Server (NTRS)

    Scharf, Stephanie

    2015-01-01

    This Fall I worked on two different projects that culminated into a redesign of the spacesuit LLB (long life battery). I also did some work on the PLSS (personal life support system) battery with EC. My first project was redlining the work instruction for completing DPAs (destructive physical analysis) on battery cells in the Branch. The purpose of this document is to create a standard process and ensure that the data is collected in the same way, no matter who carries out the analysis. I observed three DPAs, conducted one with help, and conducted two on my own, all while taking notes on the procedure. These notes were used to write the final work instruction, which will become the Branch standard. My second project continued the work of the Summer co-op before me. I tested aluminum heat sinks for their ability to provide good thermal conduction and structural support during a thermal runaway event. The heat sinks had been designed by the previous Summer co-op, but there was not much time for testing before he left. We thus ran tests with a heater on the bottom of a trigger cell to try to drive thermal runaway and ensure that it will not propagate to adjacent cells. We also ran heat-to-vent tests in an oven to see if the assembly provided structural support and prevented sidewall rupture during thermal runaway. These tests were carried out at ESTA (Energy Systems Test Area) and are providing very promising results, indicating that safe, high performing (>180 Wh/kg) designs are possible. My main project was a redesign of the LLB (Lightweight Lithium Battery). Another summer intern had done some testing and concluded that there was no simple fix to mitigate thermal runaway propagation hazards in the existing design. The only option was a clean sheet redesign of the battery. I was given a volume and ideal energy density, and the rest of the design was up to me. First, I created new heat sink banks in CREO, using the information gathered in the metal heat sink tests from the summer intern. After this, I made capture plates to hold the cells in place, and I worked on nickel bussings for the electrical connections between the cells. Finally, I designed the test box enclosure that included sections for flame arresting materials. The battery brick design, which is the heart of the battery, promises to become the first for a manned spacecraft application to achieve > 180 Wh/kg. My work in redlining the DPA work instructions will also be used in selecting the cells for the battery. We had a few options for cells that would provide the necessary power output and needed to make a choice. We repeatedly charged and discharged cells for around a month until they went through 100 lifecycles. The plan was to compare the DPA results on fresh and cycled cells from each manufacturer to see if cycling introduces any differences. After the complete LLB design was approved, the parts were ordered and testing should begin the first week of December. Cutting open a cell for DPA After photo from oven heat-to-vent test

  9. 2007 Nissan Altima-2351 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's (DOE) Advanced Vehicle Testing Activity (AVTA) conducts several different types of tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of on-road accelerated testing. This report documents the battery testing performed and the battery testing results for the 2007 Nissan Altima HEV, number 2351 (VIN 1N4CL21E87C172351). The battery testing was performed by the Electric Transportation Engineering Corporation (eTec). The Idaho National Laboratory and eTec conduct the AVTA for DOE’s Vehicle Technologies Program.

  10. 40 CFR 63.7325 - What test methods and other procedures must I use to demonstrate initial compliance with the TDS...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... applied to the coke (e.g., from the header that feeds water to the quench tower reservoirs). Conduct... sample of the quench water as applied to the coke (e.g., from the header that feeds water to the quench...

  11. 40 CFR 63.7325 - What test methods and other procedures must I use to demonstrate initial compliance with the TDS...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... applied to the coke (e.g., from the header that feeds water to the quench tower reservoirs). Conduct... sample of the quench water as applied to the coke (e.g., from the header that feeds water to the quench...

  12. 40 CFR 63.7325 - What test methods and other procedures must I use to demonstrate initial compliance with the TDS...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... applied to the coke (e.g., from the header that feeds water to the quench tower reservoirs). Conduct... sample of the quench water as applied to the coke (e.g., from the header that feeds water to the quench...

  13. 40 CFR 63.7325 - What test methods and other procedures must I use to demonstrate initial compliance with the TDS...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... applied to the coke (e.g., from the header that feeds water to the quench tower reservoirs). Conduct... sample of the quench water as applied to the coke (e.g., from the header that feeds water to the quench...

  14. Differential Validities for Shop Courses: Proposal B: Follow-Up of Subjects' Work Experiences. Final Report. Vol I: Procedures and Results.

    ERIC Educational Resources Information Center

    Isabelle, L. A.; Lokan, J. J.

    Follow-up information was collected on 1500 students who attended a two-year occupational high school, in order to relate predictor measures to success during training and subsequent job success. Although not predictive of dropouts, variables in the pre-test battery did predict performance in academic and shop courses; ratings of job success were…

  15. Potential use of battery packs from NCAP tested vehicles.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamb, Joshua; Orendorff, Christopher J.

    2013-10-01

    Several large electric vehicle batteries available to the National Highway Traffic Safety Administration are candidates for use in future safety testing programs. The batteries, from vehicles subjected to NCAP crashworthiness testing, are considered potentially damaged due to the nature of testing their associated vehicles have been subjected to. Criteria for safe shipping to Sandia is discussed, as well as condition the batteries must be in to perform testing work. Also discussed are potential tests that could be performed under a variety of conditions. The ultimate value of potential testing performed on these cells will rest on the level of accessmore » available to the battery pack, i.e. external access only, access to the on board monitoring system/CAN port or internal electrical access to the battery. Greater access to the battery than external visual and temperature monitoring would likely require input from the battery manufacturer.« less

  16. EVA Metro Sedan electric-propulsion system: test and evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reimers, E.

    1979-09-01

    The procedure and results of the performance evaluation of the EVA Metro Sedan (car No. 1) variable speed dc chopper motor drive and its three speed automatic transmission are presented. The propulsion system for a battery powered vehicle manufactured by Electric Vehicle Associates, Valley View, Ohio, was removed from the vehicle, mounted on the programmable electric dynamometer test facility and evaluated with the aid of a hp 3052A Data Acquisition System. Performance data for the automatic transmission, the solid state dc motor speed controller, and the dc motor in the continuous and pulsating dc power mode, as derived on themore » dynamometer test facility, as well as the entire propulsion system are given. This concept and the system's components were evaluated in terms of commercial applicability, maintainability, and energy utility to establish a design base for the further development of this system or similar propulsion drives. The propulsion system of the EVA Metro Sedan is powered by sixteen 6-volt traction batteries, Type EV 106 (Exide Battery Mfg. Co.). A thyristor controlled cable form Pulsomatic Mark 10 controller, actuated by a foot throttle, controls the voltage applied to a dc series field motor, rated at 10 hp at 3800 rpm (Baldor Electric Co.). Gear speed reduction to the wheel is accomplished by the original equipment three speed automatic transmission with torque converter (Renault 12 Sedan). The brake consists of a power-assisted, hydraulic braking system with front wheel disk and rear drum. An ability to recuperate electric energy with subsequent storage in the battery power supply is not provided.« less

  17. Performance of the Lester battery charger in electric vehicles

    NASA Technical Reports Server (NTRS)

    Vivian, H. C.; Bryant, J. A.

    1984-01-01

    Tests are performed on an improved battery charger. The primary purpose of the testing is to develop test methodologies for battery charger evaluation. Tests are developed to characterize the charger in terms of its charge algorithm and to assess the effects of battery initial state of charge and temperature on charger and battery efficiency. Tests show this charger to be a considerable improvement in the state of the art for electric vehicle chargers.

  18. Air Force Phillips Laboratory Battery Program overview

    NASA Technical Reports Server (NTRS)

    House, Shaun

    1992-01-01

    Battery development and testing efforts at Phillips Laboratory fall into three main categories: nickel hydrogen, sodium sulfur, and solid state batteries. Nickel hydrogen work is broken down into a Low Earth Orbit (LEO) Life Test Program, a LEO Pulse Test Program, and a Hydrogen Embrittlement Investigation. Sodium sulfur work is broken down into a Geosynchronous Earth Orbit (GEO) Battery Flight Test and a Hot Launch Evaluation. Solid state polymer battery work consists of a GEO Battery Development Program, a Pulse Power Battery Small Business Innovation Research (SBIR), and an in-house evaluation of current generation laboratory cells. An overview of the program is presented.

  19. 2010 Toyota Prius VIN 0462 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Matthew Shirk

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Toyota Prius HEV (VIN: JTDKN3DU2A5010462). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activitymore » for the Vehicle Technologies Program of the U.S. Department of Energy.« less

  20. 2010 Honda Insight VIN 0141 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Honda Insight HEV (VIN: JHMZE2H78AS010141). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activitymore » for the Vehicle Technologies Program of the U.S. Department of Energy.« less

  1. 2010 Toyota Prius VIN 6063 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Matthew Shirk

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Toyota Prius HEV (VIN JTDKN3DU5A0006063). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activitymore » for the Vehicle Technologies Program of the U.S. Department of Energy.« less

  2. 2010 Honda Insight VIN 1748 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Matthew Shirk

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on road fleet testing. This report documents battery testing performed for the 2010 Honda Insight HEV (VIN: JHMZE2H59AS011748). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activitymore » for the Vehicle Technologies Program of the U.S. Department of Energy.« less

  3. 2010 Ford Fusion VIN 4757 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Matthew Shirk

    2013-01-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on-road fleet testing. This report documents battery testing performed for the 2010 Ford Fusion HEV (VIN: 3FADP0L34AR144757). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the Advanced Vehicle Testing Activity for themore » Vehicle Technologies Program of the U.S. Department of Energy.« less

  4. Cell overcharge testing inside sodium metal halide battery

    NASA Astrophysics Data System (ADS)

    Frutschy, Kris; Chatwin, Troy; Bull, Roger

    2015-09-01

    Testing was conducted to measure electrical performance and safety of the General Electric Durathon™ E620 battery module (600 V class 20 kWh) during cell overcharge. Data gathered from this test was consistent with SAE Electric Vehicle Battery Abuse Testing specification J2464 [1]. After cell overcharge failure and 24 A current flow for additional 60 minutes, battery was then discharged at 7.5 KW average power to 12% state of charge (SOC) and recharged back to 100% SOC. This overcharging test was performed on two cells. No hydrogen chloride (HCl) gas was detected during front cell (B1) test, and small amount (6.2 ppm peak) was measured outside the battery after center cell (F13) overcharge. An additional overcharge test was performed per UL Standard 1973 - Batteries for Use in Light Electric Rail (LER) Applications and Stationary Applications[2]. With the battery at 11% SOC and 280 °C float temperature, an individual cell near the front (D1) was deliberately imbalanced by charging it to 62% SOC. The battery was then recharged to 100% SOC. In all three tests, the battery cell pack was stable and individual cell failure did not propagate to other cells. Battery discharge performance, charge performance, and electrical isolation were normal after all three tests.

  5. Batteries for Electric Vehicles

    NASA Technical Reports Server (NTRS)

    Conover, R. A.

    1985-01-01

    Report summarizes results of test on "near-term" electrochemical batteries - (batteries approaching commercial production). Nickel/iron, nickel/zinc, and advanced lead/acid batteries included in tests and compared with conventional lead/acid batteries. Batteries operated in electric vehicles at constant speed and repetitive schedule of accerlerating, coasting, and braking.

  6. Laboratory testing of the (Japan Storage Battery) traction batteries GS E75A and GS E150H

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report describes the testing of the GS E75A and GS E150H flooded lead-acid 12-volt traction batteries and compares the selected batteries to U.S.-made electric vehicle batteries. The results and conclusions of the testing are presented.

  7. Ampule tests to simulate glass corrosion in ambient temperature lithium batteries. Volume 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Douglas, S.C.; Bunker, B.C.; Crafts, C.C.

    1984-06-01

    Glass corrosion in battery headers has been found to limit the shelf life of ambient temperature lithium batteries. Glass corrosion can lead to loss of battery electrolytes or to shorts across the conductive corrosion product. Tests have been conducted which simulate the corrosive environment in a battery by sealing headers attached to lithium metal into Pyrex ampules containing battery electrolyte. Using the ampule test, glass corrosion kinetics have been determined at 70/sup 0/C for the Li/SO/sub 2/, Li/SOCl/sub 2/, and Li/SOCl/sub 2/ + BrCl battery systems. Test results indicate that corrosion of commercial glass compositions is extensive in all electrolytesmore » tested, resulting in predicted battery failures after several months. Sandia's TA-23 glass corrodes at a much slower rate, indicating a projected battery lifetime of over five years in the Li/SO/sub 2/ system. Test results reveal that corrosion kinetics are sensitive to header polarization, stress, and configuration as well as glass composition.« less

  8. Hybrid vehicle control

    DOEpatents

    Shallvari, Iva; Velnati, Sashidhar; DeGroot, Kenneth P.

    2015-07-28

    A method and apparatus for heating a catalytic converter's catalyst to an efficient operating temperature in a hybrid electric vehicle when the vehicle is in a charge limited mode such as e.g., the charge depleting mode or when the vehicle's high voltage battery is otherwise charge limited. The method and apparatus determine whether a high voltage battery of the vehicle is incapable of accepting a first amount of charge associated with a first procedure to warm-up the catalyst. If it is determined that the high voltage battery is incapable of accepting the first amount of charge, a second procedure with an acceptable amount of charge is performed to warm-up the catalyst.

  9. Impact of shuttle environment on prelaunch handling of nickel-hydrogen batteries

    NASA Technical Reports Server (NTRS)

    Green, R. S.

    1986-01-01

    Deployment of the American Satellite Company 1 spacecraft for the Space Shuttle Discovery in August 1985 set a new milestone in nickel-hydrogen battery technology. This communications satellite is equipped with two 35 Ah nickel-hydrogen batteries and it is the first such satellite launched into orbit via the Space Shuttle. The prelaunch activities, combined with the environmental constraints onboard the Shuttle, led to the development of a new battery handling procedure. An outline of the prelaunch activities, with particular attention to battery charging, is presented.

  10. Electro-thermal battery model identification for automotive applications

    NASA Astrophysics Data System (ADS)

    Hu, Y.; Yurkovich, S.; Guezennec, Y.; Yurkovich, B. J.

    This paper describes a model identification procedure for identifying an electro-thermal model of lithium ion batteries used in automotive applications. The dynamic model structure adopted is based on an equivalent circuit model whose parameters are scheduled on the state-of-charge, temperature, and current direction. Linear spline functions are used as the functional form for the parametric dependence. The model identified in this way is valid inside a large range of temperatures and state-of-charge, so that the resulting model can be used for automotive applications such as on-board estimation of the state-of-charge and state-of-health. The model coefficients are identified using a multiple step genetic algorithm based optimization procedure designed for large scale optimization problems. The validity of the procedure is demonstrated experimentally for an A123 lithium ion iron-phosphate battery.

  11. Binding S0.6 Se0.4 in 1D Carbon Nanofiber with CS Bonding for High-Performance Flexible Li-S Batteries and Na-S Batteries.

    PubMed

    Yao, Yu; Zeng, Linchao; Hu, Shuhe; Jiang, Yu; Yuan, Beibei; Yu, Yan

    2017-05-01

    A one-step synthesis procedure is developed to prepare flexible S 0.6 Se 0.4 @carbon nanofibers (CNFs) electrode by coheating S 0.6 Se 0.4 powder with electrospun polyacrylonitrile nanofiber papers at 600 °C. The obtained S 0.6 Se 0.4 @CNFs film can be used as cathode material for high-performance Li-S batteries and room temperature (RT) Na-S batteries directly. The superior lithium/sodium storage performance derives from its rational structure design, such as the chemical bonding between Se and S, the chemical bonding between S 0.6 Se 0.4 and CNFs matrix, and the 3D CNFs network. This easy one-step synthesis procedure provides a feasible route to prepare electrode materials for high-performance Li-S and RT Na-S batteries. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. A 31-day battery-operated recording weather station.

    Treesearch

    Richard J. Barney

    1972-01-01

    The battery-powered recording weather station measures and records wet bulb temperature, dry bulb temperature, wind travel, and rainfall for 31 days. Assembly procedures and cost of supplies and components are discussed.

  13. 40 CFR 63.7328 - How do I demonstrate initial compliance with the operation and maintenance requirements that...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial Compliance...); (b) You will operate each by-product coke oven battery and each capture system and control device applied to pushing emissions from a coke oven battery according to the procedures in the plans beginning...

  14. 40 CFR 63.7328 - How do I demonstrate initial compliance with the operation and maintenance requirements that...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial...); (b) You will operate each by-product coke oven battery and each capture system and control device applied to pushing emissions from a coke oven battery according to the procedures in the plans beginning...

  15. 40 CFR 63.7328 - How do I demonstrate initial compliance with the operation and maintenance requirements that...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial...); (b) You will operate each by-product coke oven battery and each capture system and control device applied to pushing emissions from a coke oven battery according to the procedures in the plans beginning...

  16. 40 CFR 63.7328 - How do I demonstrate initial compliance with the operation and maintenance requirements that...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial...); (b) You will operate each by-product coke oven battery and each capture system and control device applied to pushing emissions from a coke oven battery according to the procedures in the plans beginning...

  17. 40 CFR 63.7328 - How do I demonstrate initial compliance with the operation and maintenance requirements that...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery Stacks Initial...); (b) You will operate each by-product coke oven battery and each capture system and control device applied to pushing emissions from a coke oven battery according to the procedures in the plans beginning...

  18. Microwave-Assisted Synthesis of NiCo2O4 Double-Shelled Hollow Spheres for High-Performance Sodium Ion Batteries

    NASA Astrophysics Data System (ADS)

    Zhang, Xiong; Zhou, Yanping; Luo, Bin; Zhu, Huacheng; Chu, Wei; Huang, Kama

    2018-03-01

    The ternary transitional metal oxide NiCo2O4 is a promising anode material for sodium ion batteries due to its high theoretical capacity and superior electrical conductivity. However, its sodium storage capability is severely limited by the sluggish sodiation/desodiation reaction kinetics. Herein, NiCo2O4 double-shelled hollow spheres were synthesized via a microwave-assisted, fast solvothermal synthetic procedure in a mixture of isopropanol and glycerol, followed by annealing. Isopropanol played a vital role in the precipitation of nickel and cobalt, and the shrinkage of the glycerol quasi-emulsion under heat treatment was responsible for the formation of the double-shelled nanostructure. The as-synthesized product was tested as an anode material in a sodium ion battery, was found to exhibit a high reversible specific capacity of 511 mAh g-1 at 100 mA g-1, and deliver high capacity retention after 100 cycles. [Figure not available: see fulltext.

  19. SMS/GOES cell and battery data analysis report

    NASA Technical Reports Server (NTRS)

    Armantrout, J. D.

    1977-01-01

    The nickel-cadmium battery design developed for the Synchronous Meteorological Satellite (SMS) and Geostationary Operational Environmental Satellite (GOES) provided background and guidelines for future development, manufacture, and application of spacecraft batteries. SMS/GOES battery design, development, qualification testing, acceptance testing, and life testing/mission performance characteristics were evaluated for correlation with battery cell manufacturing process variables.

  20. Life test of a nickel cadmium battery with a protection/reconditioning circuit

    NASA Technical Reports Server (NTRS)

    Lanier, J. R., Jr.; Bush, J. R., Jr.

    1981-01-01

    Results are discussed for a Ni-Cd battery test over a period of 8 years, 2 months and 44,213 simulated low Earth orbits. The battery cells were protected against overdischarge and reversal at discharge rates up to 25 amperes (1.25C) by a battery protection and reconditioning circuit. The circuit performed flawlessly during the test, and proved its value, both as a battery reconditioner and a cell protection device. Battery cell failures are also discussed. The test demonstrated the viability of using Ni-Cd batteries at depth-of-discharge up to 25 percent for over 5 years in a low Earth orbit.

  1. Testing of the Eagle-Picher nickel-iron, the Globe ISOA lead-acid, and the Westinghouse nickel-iron battery subsystems in an electric-vehicle environment

    NASA Technical Reports Server (NTRS)

    Hewitt, R.; Bryant, J.

    1982-01-01

    Three full size developmental batteries were tested with electric vehicles; two nickel-iron batteries and a lead-acid battery. Constant speed and driving schedule tests were done on a chassis dynamometer. Several aspects of battery performance were evaluated for capacity, recharge efficiency, voltage response, and self discharge. Each of these three batteries exhibited some strengths and some weaknesses.

  2. Chemically rechargeable battery

    NASA Technical Reports Server (NTRS)

    Graf, James E. (Inventor); Rowlette, John J. (Inventor)

    1984-01-01

    Batteries (50) containing oxidized, discharged metal electrodes such as an iron-air battery are charged by removing and storing electrolyte in a reservoir (98), pumping fluid reductant such as formalin (aqueous formaldehyde) from a storage tank (106) into the battery in contact with the surfaces of the electrodes. After sufficient iron hydroxide has been reduced to iron, the spent reductant is drained, the electrodes rinsed with water from rinse tank (102) and then the electrolyte in the reservoir (106) is returned to the battery. The battery can be slowly electrically charged when in overnight storage but can be quickly charged in about 10 minutes by the chemical procedure of the invention.

  3. Testing of sealed lead-acid batteries

    NASA Astrophysics Data System (ADS)

    Bush, D. M.; Sealey, J. D.; Miller, D. W.

    1984-02-01

    Sealed lead acid batteries under development were tested. The goal was to develop a totally maintenance free sealed lead acid battery capable of deep discharge operation in a photovoltaic power system. Sealed lead acid batteries and a group of conventional, flooded lead acid batteries were exposed to a matrix test plan, with some approaching 1000 cycles. This performance was achieved with the standard National Electrical Manufacturers' Association cycle test, and the partial state of charge cycle test. Modes of failure are investigated.

  4. Field evaluation of a behavioral test battery for DWI

    DOT National Transportation Integrated Search

    1983-09-01

    This paper presents initial findings from a recently conducted field evaluation of a sobriety test battery. Police officers from four jurisdictions were trained in the use of the sobriety test battery. They then administered the battery to drivers st...

  5. International Space Station Lithium-Ion Main Battery Thermal Runaway Propagation Test

    NASA Technical Reports Server (NTRS)

    Dalton, Penni J.; North, Tim

    2017-01-01

    In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace the aging Ni-H2 batteries on the primary Electric Power System (EPS). After the Boeing 787 Li-Ion battery fires, the NASA Engineering and Safety Center (NESC) Power Technical Discipline Team was tasked by ISS to investigate the possibility of Thermal Runaway Propagation (TRP) in all Li-Ion batteries used on the ISS. As part of that investigation, NESC funded a TRP test of an ISS EPS non-flight Li-Ion battery. The test was performed at NASA White Sands Test Facility in October 2016. This paper will discuss the work leading up to the test, the design of the test article, and the test results.

  6. A Lumped Computational Model for Sodium Sulfur Battery Analysis

    NASA Astrophysics Data System (ADS)

    Wu, Fan

    Due to the cost of materials and time consuming testing procedures, development of new batteries is a slow and expensive practice. The purpose of this study is to develop a computational model and assess the capabilities of such a model designed to aid in the design process and control of sodium sulfur batteries. To this end, a transient lumped computational model derived from an integral analysis of the transport of species, energy and charge throughout the battery has been developed. The computation processes are coupled with the use of Faraday's law, and solutions for the species concentrations, electrical potential and current are produced in a time marching fashion. Properties required for solving the governing equations are calculated and updated as a function of time based on the composition of each control volume. The proposed model is validated against multi- dimensional simulations and experimental results from literatures, and simulation results using the proposed model is presented and analyzed. The computational model and electrochemical model used to solve the equations for the lumped model are compared with similar ones found in the literature. The results obtained from the current model compare favorably with those from experiments and other models.

  7. 2011 Chevrolet Volt VIN 0815 Plug-In Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Matthew Shirk; Jeffrey Wishart

    2013-07-01

    The U.S. Department of Energy (DOE) Advanced Vehicle Testing Activity (AVTA) program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on plug-in hybrid electric vehicles (PHEVs), including testing the PHEV batteries when both the vehicles and batteries are new and at the conclusion of 12,000 miles of on-road fleet testing. This report documents battery testing performed for the 2011 Chevrolet Volt PHEV (VIN 1G1RD6E48BU100815). The battery testing was performed by the Electric Transportation Engineering Corporation (eTec) dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on themore » AVTA for the Vehicle Technologies Program of the DOE.« less

  8. Sodium-sulfur battery flight experiment definition study

    NASA Technical Reports Server (NTRS)

    Chang, Rebecca; Minck, Robert

    1990-01-01

    Sodium-sulfur batteries are considered to be one of the most likely battery systems for space applications. Compared with the Ni-H2 or Ni-Co battery systems, Na-S batteries offer a mass reduction by a factor of 2 to 4, representing significant launch cost savings or increased payload mass capabilities. The Na-S battery operates at between 300 and 400 C, using liquid sodium and sulfur/polysulfide electrodes and solid ceramic electrolyte; the transport of the electrode materials to the surface of the electrolyte is through wicking/capillary forces. This paper describes five tests identified for the Na-S battery flight experiment definition study, which include the cell characterization test, the reactant distribution test, the current/temperature distribution test, the freeze/thaw test, and the multicell LEO test. A schematic diagram of Na-S cell is included.

  9. French consensus procedure for assessing cognitive function in Parkinson's disease.

    PubMed

    Dujardin, K; Auzou, N; Lhommée, E; Czernecki, V; Dubois, B; Fradet, A; Maltete, D; Meyer, M; Pineau, F; Schmitt, E; Sellal, F; Tison, F; Vidal, T; Azulay, J-P; Welter, M-L; Corvol, J-C; Durif, F; Rascol, O

    2016-11-01

    One of the objectives of the French expert centers for Parkinson's disease (NS-Park) network was to determine a consensus procedure for assessing cognitive function in patients with Parkinson's. This article presents this procedure and briefly describes the selected tests. A group of 13 experts used the Delphi method for consensus building to define the overall structure and components of the assessment procedure. For inclusion in the battery, tests had to be validated in the French language, require little motor participation, have normative data and be recognized by the international community. Experimental tasks and tests requiring specific devices were excluded. Two possibilities were identified, depending on whether an abbreviated or comprehensive assessment of cognitive function was necessary. For an abbreviated assessment, the experts recommended the Montreal Cognitive Assessment (MoCA) as a screening test for cognitive impairment or dementia. For a comprehensive neuropsychological assessment, the experts recommended assessing global efficiency plus the five main cognitive domains (attention and working memory, executive function, episodic memory, visuospatial function and language) that may be impaired in Parkinson's disease, using two tests for each domain. A common procedure for assessing cognitive function is now available across the French network dedicated to Parkinson's disease, and is recommended for both research and clinical practice. It will also help to promote standardization of the neuropsychological assessment of Parkinson's disease. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. Testing Conducted for Lithium-Ion Cell and Battery Verification

    NASA Technical Reports Server (NTRS)

    Reid, Concha M.; Miller, Thomas B.; Manzo, Michelle A.

    2004-01-01

    The NASA Glenn Research Center has been conducting in-house testing in support of NASA's Lithium-Ion Cell Verification Test Program, which is evaluating the performance of lithium-ion cells and batteries for NASA mission operations. The test program is supported by NASA's Office of Aerospace Technology under the NASA Aerospace Flight Battery Systems Program, which serves to bridge the gap between the development of technology advances and the realization of these advances into mission applications. During fiscal year 2003, much of the in-house testing effort focused on the evaluation of a flight battery originally intended for use on the Mars Surveyor Program 2001 Lander. Results of this testing will be compared with the results for similar batteries being tested at the Jet Propulsion Laboratory, the Air Force Research Laboratory, and the Naval Research Laboratory. Ultimately, this work will be used to validate lithium-ion battery technology for future space missions. The Mars Surveyor Program 2001 Lander battery was characterized at several different voltages and temperatures before life-cycle testing was begun. During characterization, the battery displayed excellent capacity and efficiency characteristics across a range of temperatures and charge/discharge conditions. Currently, the battery is undergoing lifecycle testing at 0 C and 40-percent depth of discharge under low-Earth-orbit (LEO) conditions.

  11. Optimization of batteries for plug-in hybrid electric vehicles

    NASA Astrophysics Data System (ADS)

    English, Jeffrey Robb

    This thesis presents a method to quickly determine the optimal battery for an electric vehicle given a set of vehicle characteristics and desired performance metrics. The model is based on four independent design variables: cell count, cell capacity, state-of-charge window, and battery chemistry. Performance is measured in seven categories: cost, all-electric range, maximum speed, acceleration, battery lifetime, lifetime greenhouse gas emissions, and charging time. The performance of each battery is weighted according to a user-defined objective function to determine its overall fitness. The model is informed by a series of battery tests performed on scaled-down battery samples. Seven battery chemistries were tested for capacity at different discharge rates, maximum output power at different charge levels, and performance in a real-world automotive duty cycle. The results of these tests enable a prediction of the performance of the battery in an automobile. Testing was performed at both room temperature and low temperature to investigate the effects of battery temperature on operation. The testing highlighted differences in behavior between lithium, nickel, and lead based batteries. Battery performance decreased with temperature across all samples with the largest effect on nickel-based chemistries. Output power also decreased with lead acid batteries being the least affected by temperature. Lithium-ion batteries were found to be highly efficient (>95%) under a vehicular duty cycle; nickel and lead batteries have greater losses. Low temperatures hindered battery performance and resulted in accelerated failure in several samples. Lead acid, lead tin, and lithium nickel alloy batteries were unable to complete the low temperature testing regime without losing significant capacity and power capability. This is a concern for their applicability in electric vehicles intended for cold climates which have to maintain battery temperature during long periods of inactivity. Three sample optimizations were performed: a compact car, a, truck, and a sports car. The compact car benefits from increased battery capacity despite the associated higher cost. The truck returned the smallest possible battery of each chemistry, indicating that electrification is not advisable. The sports car optimization resulted in the largest possible battery, indicating large performance from increased electrification. These results mirror the current state of the electric vehicle market.

  12. Positive electrode processing for Hughes NiH2 cells

    NASA Technical Reports Server (NTRS)

    Bleser, C. A.

    1982-01-01

    The basic procedures were developed for the manufacture of nickel cadmium batteries. An electrochemical impregnation in an aqueous ethanol solution is used in this process. Several additional controls were instituted for production of flight electrodes, including a Hughes controlled MCD, a solution reserved exclusively for the impregnation of Hughes positive electrodes a system of complete traceability for individual electrodes, an electrical characterization test to provide information on weight and capacity at the plaque level, and a stress test to provide data on capacity, weight, and physical parameters at the electrode level.

  13. Mental rotation - A key to mitigation of motion sickness in the virtual environments?

    NASA Technical Reports Server (NTRS)

    Parker, Donald E.; Harm, Deborah L.

    1992-01-01

    If mental rotation is important for the reduction of motion sickness and complement performance in virtual environments (VEs), the use of the Howard (1982) mental rotation test battery may identify individuals with lower susceptibility to VE-induced motion sickness and therefore a greater probability of success as VE operators. An apparatus and its associated procedures are currently under development for astronaut microgravity training aimed at reducing motion sickness; it is hypothesized that this system may be of significance to VE testing and training.

  14. Satellite battery testing status

    NASA Astrophysics Data System (ADS)

    Haag, R.; Hall, S.

    1986-09-01

    Because of the large numbers of satellite cells currently being tested and anticipated at the Naval Weapons Support Center (NAVWPNSUPPCEN) Crane, Indiana, satellite cell testing is being integrated into the Battery Test Automation Project (BTAP). The BTAP, designed to meet the growing needs for battery testing at the NAVWPNSUPPCEN Crane, will consist of several Automated Test Stations (ATSs) which monitor batteries under test. Each ATS will interface with an Automation Network Controller (ANC) which will collect test data for reduction.

  15. Satellite battery testing status

    NASA Technical Reports Server (NTRS)

    Haag, R.; Hall, S.

    1986-01-01

    Because of the large numbers of satellite cells currently being tested and anticipated at the Naval Weapons Support Center (NAVWPNSUPPCEN) Crane, Indiana, satellite cell testing is being integrated into the Battery Test Automation Project (BTAP). The BTAP, designed to meet the growing needs for battery testing at the NAVWPNSUPPCEN Crane, will consist of several Automated Test Stations (ATSs) which monitor batteries under test. Each ATS will interface with an Automation Network Controller (ANC) which will collect test data for reduction.

  16. Effects of Electric Vehicle Fast Charging on Battery Life and Vehicle Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthew Shirk; Jeffrey Wishart

    2015-04-01

    As part of the U.S. Department of Energy’s Advanced Vehicle Testing Activity, four new 2012 Nissan Leaf battery electric vehicles were instrumented with data loggers and operated over a fixed on-road test cycle. Each vehicle was operated over the test route, and charged twice daily. Two vehicles were charged exclusively by AC level 2 EVSE, while two were exclusively DC fast charged with a 50 kW charger. The vehicles were performance tested on a closed test track when new, and after accumulation of 50,000 miles. The traction battery packs were removed and laboratory tested when the vehicles were new, andmore » at 10,000-mile intervals. Battery tests include constant-current discharge capacity, electric vehicle pulse power characterization test, and low peak power tests. The on-road testing was carried out through 70,000 miles, at which point the final battery tests were performed. The data collected over 70,000 miles of driving, charging, and rest are analyzed, including the resulting thermal conditions and power and cycle demands placed upon the battery. Battery performance metrics including capacity, internal resistance, and power capability obtained from laboratory testing throughout the test program are analyzed. Results are compared within and between the two groups of vehicles. Specifically, the impacts on battery performance, as measured by laboratory testing, are explored as they relate to battery usage and variations in conditions encountered, with a primary focus on effects due to the differences between AC level 2 and DC fast charging. The contrast between battery performance degradation and the effect on vehicle performance is also explored.« less

  17. 9. Photocopy of command flow chart of NIKE Battalion, Headquarters ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Photocopy of command flow chart of NIKE Battalion, Headquarters Battery and Missile Battery from Procedures and Drills for NIKE Ajax System, Department of the Army Field Manual, FM-44-80 from Institute for Military History, Carlisle Barracks, Carlisle, PA 1956 - NIKE Missile Battery PR-79, East Windsor Road south of State Route 101, Foster, Providence County, RI

  18. Lithium battery fires: implications for air medical transport.

    PubMed

    Thomas, Frank; Mills, Gordon; Howe, Robert; Zobell, Jim

    2012-01-01

    Lithium-ion batteries provide more power and longer life to electronic medical devices, with the benefits of reduced size and weight. It is no wonder medical device manufacturers are designing these batteries into their products. Lithium batteries are found in cell phones, electronic tablets, computers, and portable medical devices such as ventilators, intravenous pumps, pacemakers, incubators, and ventricular assist devices. Yet, if improperly handled, lithium batteries can pose a serious fire threat to air medical transport personnel. Specifically, this article discusses how lithium-ion batteries work, the fire danger associated with them, preventive measures to reduce the likelihood of a lithium battery fire, and emergency procedures that should be performed in that event. Copyright © 2012 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.

  19. Mariner Mars 1971 battery design, test, and flight performance

    NASA Technical Reports Server (NTRS)

    Bogner, R. S.

    1973-01-01

    The design, integration, fabrication, test results, and flight performance of the battery system for the Mariner Mars spacecraft launched in May 1971 are presented. The battery consists of 26 20-Ah hermetically sealed nickel-cadmium cells housed in a machined magnesium chassis. The battery package weighs 29.5 kg and is unique in that the chassis also serves as part of the spacecraft structure. Active thermal control is accomplished by louvers mounted to the battery baseplate. Battery charge is accomplished by C/10 and C/30 constant current chargers. The switch from the high-rate to low-rate charge is automatic, based on terminal voltage. Additional control is possible by ground command or onboard computer. The performance data from the flight battery is compared to the data from various battery tests in the laboratory. Flight battery data was predictable based on ground test data.

  20. Testing and development of electric vehicle batteries for EPRI Electric Transportation Program

    NASA Astrophysics Data System (ADS)

    1985-11-01

    Argonne National Laboratory conducted an electric-vehicle battery testing and development program for the Electric Power Research Institute. As part of this program, eighteen battery modules previously developed by Johnson Controls, Inc. were tested. This type of battery (EV-2300 - an improved state-of-the-art lead-acid battery) was designed specifically for improved performance, range, and life in electric vehicles. In order to obtain necessary performance data, the batteries were tested under various duty cycles typical of normal service. This program, supported by the Electric Power Research Institute, consisted of three tasks: determination of the effect of cycle life vs peak power and rest period, determination of the impact of charge method on cycle life, and evaluation of the EV-2300 battery system. Two supporting studies were also carried out: one on thermal management of electric-vehicle batteries and one on enhanced utilization of active material in lead-acid batteries.

  1. Assessment of Lithium-based Battery Electrolytes Developed under the NASA PERS Program

    NASA Technical Reports Server (NTRS)

    Bennett, William R.; Baldwin, Richard S.

    2006-01-01

    Recently, NASA formally completed the Polymer Energy Rechargeable System (PERS) Program, which was established in 2000 in collaboration with the Air Force Research Laboratory (AFRL) to support the development of polymer-based, lithium-based cell chemistries and battery technologies to address the next generation of aerospace applications and mission needs. The goal of this program was to ultimately develop an advanced, space-qualified battery technology, which embodied a solid polymer electrolyte (SPE) and complementary components, with improved performance characteristics that would address future aerospace battery requirements. Programmatically, the PERS initiative exploited both interagency collaborations to address common technology and engineering issues and the active participation of academia and private industry. The initial program phases focused on R&D activities to address the critical technical issues and challenges at the cell level. A variety of cell and polymeric electrolyte concepts were pursued as part of the development efforts undertaken at numerous governmental, industrial and academic laboratories. Numerous candidate electrolyte materials were developed, synthesized and optimized for evaluation. Utilizing the component screening facility and the "standardized" test procedures developed at the NASA Glenn Research Center, electrochemical screening and performance evaluations of promising candidate materials were completed. This overview summarizes test results for a variety of candidate electrolyte materials that were developed under the PERS Program. Electrolyte properties are contrasted and compared to the original project goals, and the strengths and weaknesses of the electrolyte chemistries are discussed. Limited cycling data for full-cells using lithium metal and vanadium oxide electrodes are also presented. Based on measured electrolyte properties, the projected performance characteristics and temperature limitations of batteries utilizing the advanced electrolytes and components have been estimated. Limitations for the achievement of practical performance levels are also discussed, as well as needs for future research and development.

  2. Environmental sampling of lead near a battery reprocessing factory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leung, H.W.

    1988-09-01

    Exposed workers in lead smelting plants and lead storage battery factories have reported illnesses related to inhalation of lead oxide fumes. The residential community of La Gloria, a town of about 15,000 people located approximately 13 km southwest of Tijuana, Baja California, Mexico was an area where residents were concerned about possible health effects and environmental contamination from lead due to the proximity of battery factory that used lead oxide in the battery grid separation procedure. This study was undertaken to investigate the lead levels in the soil, plant and water collected in various areas around this battery reprocessing plant.

  3. A portable battery for objective, non-obstrusive measures of human performances

    NASA Technical Reports Server (NTRS)

    Kennedy, R. S.

    1984-01-01

    The need for a standardized battery of human performance tests to measure the effects of various treatments is pointed out. Progress in such a program is reported. Three batteries are available which differ in length and the number of tests in the battery. All tests are implemented on a portable, lap held, briefcase size microprocessor. Performances measured include: information processing, memory, visual perception, reasoning, and motor skills, programs to determine norms, reliabilities, stabilities, factor structure of tests, comparisons with marker tests, apparatus suitability. Rationale for the battery is provided.

  4. Recent developments in nickel electrode analysis

    NASA Technical Reports Server (NTRS)

    Whiteley, Richard V.; Daman, M. E.; Kaiser, E. Q.

    1991-01-01

    Three aspects of nickel electrode analysis for Nickel-Hydrogen and Nickel-Cadmium battery cell applications are addressed: (1) the determination of active material; (2) charged state nickel (as NiOOH + CoOOH); and (3) potassium ion content in the electrode. Four deloading procedures are compared for completeness of active material removal, and deloading conditions for efficient active material analyses are established. Two methods for charged state nickel analysis are compared: the current NASA procedure and a new procedure based on the oxidation of sodium oxalate by the charged material. Finally, a method for determining potassium content in an electrode sample by flame photometry is presented along with analytical results illustrating differences in potassium levels from vendor to vendor and the effects of stress testing on potassium content in the electrode. The relevance of these analytical procedures to electrode performance is reviewed.

  5. New Battery Testing Facility Could Boost Future of Electric Vehicles

    Science.gov Websites

    industry. The Battery Thermal Test Facility at the U.S. Department of Energy's (DOE) National Renewable , ambient heat sources that could effect thermal readings from the battery. The cycler can both charge and draw current from a battery, allowing for thermal testing of any voltage. It can also be used to test

  6. Effect of battery longevity on costs and health outcomes associated with cardiac implantable electronic devices: a Markov model-based Monte Carlo simulation.

    PubMed

    Schmier, Jordana K; Lau, Edmund C; Patel, Jasmine D; Klenk, Juergen A; Greenspon, Arnold J

    2017-11-01

    The effects of device and patient characteristics on health and economic outcomes in patients with cardiac implantable electronic devices (CIEDs) are unclear. Modeling can estimate costs and outcomes for patients with CIEDs under a variety of scenarios, varying battery longevity, comorbidities, and care settings. The objective of this analysis was to compare changes in patient outcomes and payer costs attributable to increases in battery life of implantable cardiac defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D). We developed a Monte Carlo Markov model simulation to follow patients through primary implant, postoperative maintenance, generator replacement, and revision states. Patients were simulated in 3-month increments for 15 years or until death. Key variables included Charlson Comorbidity Index, CIED type, legacy versus extended battery longevity, mortality rates (procedure and all-cause), infection and non-infectious complication rates, and care settings. Costs included procedure-related (facility and professional), maintenance, and infections and non-infectious complications, all derived from Medicare data (2004-2014, 5% sample). Outcomes included counts of battery replacements, revisions, infections and non-infectious complications, and discounted (3%) costs and life years. An increase in battery longevity in ICDs yielded reductions in numbers of revisions (by 23%), battery changes (by 44%), infections (by 23%), non-infectious complications (by 10%), and total costs per patient (by 9%). Analogous reductions for CRT-Ds were 23% (revisions), 32% (battery changes), 22% (infections), 8% (complications), and 10% (costs). Based on modeling results, as battery longevity increases, patients experience fewer adverse outcomes and healthcare costs are reduced. Understanding the magnitude of the cost benefit of extended battery life can inform budgeting and planning decisions by healthcare providers and insurers.

  7. Hubble Space Telescope Battery Capacity Update

    NASA Technical Reports Server (NTRS)

    Hollandsworth, Roger; Armantrout, Jon; Rao, Gopalakrishna M.

    2007-01-01

    Orbital battery performance for the Hubble Space Telescope is discussed and battery life is predicted which supports decision to replace orbital batteries by 2009-2010 timeframe. Ground characterization testing of cells from the replacement battery build is discussed, with comparison of data from battery capacity characterization with cell studies of Cycle Life and 60% Stress Test at the Naval Weapons Surface Center (NWSC)-Crane, and cell Cycle Life testing at the Marshal Space Flight Center (MSFC). The contents of this presentation includes an update to the performance of the on-orbit batteries, as well as a discussion of the HST Service Mission 4 (SM4) batteries manufactured in 1996 and activated in 2000, and a second set of SM4 backup replacement batteries which began manufacture Jan 11, 2007, with delivery scheduled for July 2008.

  8. Zinc-chloride battery technology - Status 1983

    NASA Astrophysics Data System (ADS)

    Rowan, J. W.; Carr, P.; Warde, C. J.; Henriksen, G. L.

    Zinc-chloride batteries are presently under development at Energy Development Associates (EDA) for load-leveling, electric-vehicle, and specialty applications. A 500-kWh battery system has been built at Detroit Edison's Charlotte substation near downtown Detroit. Following shakedown testing, this system will be installed at the Battery Energy Storage Test (BEST) Facility in Hillsborough, New Jersey, in July 1983. Data is presented also for a prototype 50-kWh battery which has successfully operated through 150 cycles. EDA has built and tested three 4-passenger automobiles. The maximum range achieved on a single charge was 200 miles at 40 mph. Recently, the electric-vehicle battery program at EDA has focused on commercial vehicles. Two vans, each powered with a 45-kWh zinc-chloride battery, have been built and track tested. These vehicles, which carry a payload of 1,000 pounds, have a top speed of 55 mph and an operational range in excess of 80 miles. In the specialty battery area, two 6-kWh 12-V reserve batteries have been built and tested. This type of battery offers the prospect of long shelf life and an energy density in excess of 100 Wh/lb.

  9. The assessment of colour perception, naming and knowledge: a new test device with a case study.

    PubMed

    Pagani, Rossella; Bosco, Giovanna; Dalla Valle, Elisabetta; Capitani, Erminio; Laiacona, Marcella

    2012-08-01

    Besides ocular diseases, also cerebral damage may cause colour vision deficits; cerebral lesions may be associated with a variety of clinical conditions that impair colour processing. This study presents procedures and normative data for a rapid, comprehensive seven-test battery aimed at assessing colour perception, colour naming and object colour knowledge. The norms, obtained from 96 healthy Italian participants, allow normality/pathology judgements on the basis of one-sided tolerance limits, after adjusting the score of each test for the demographic variables of the proband subjects. We also report, as an example, use of the battery in a stroke patient; this patient was chosen because her lesion affected the left temporal-occipital cortex, an area sometimes associated with a deficit of colour processing. The patient resulted normal on colour perception and colour name retrieval, but defective on object colour knowledge probed using the stimulus name. For the sound definition of the functional locus of cognitive impairment at the single case level, a multi-faceted set of tasks is necessary.

  10. [Normalisation and validation of the Brief Neuropsychological Battery as the reference neuropsychological test in multiple sclerosis].

    PubMed

    Duque, P; Ibanez, J; Del Barco, A; Sepulcre, J; de Ramon, E; Fernandez-Fernandez, O

    2012-03-01

    INTRODUCTION. The current batteries such as the Brief Repeatable Battery of Neuropsychological Tests (BRB-N) for evaluating cognitive decline in patients with multiple sclerosis are complex and time-consuming. AIM. To obtain normative values and validate a new battery. SUBJECTS AND METHODS. Four neuropsychological tests were finally included (episodic memory, the Symbol-Digit Modalities Test, a category fluency test, and the Paced Auditory Serial Addition Test). Normative values (overall and by age group) were derived by administering the battery to healthy subjects (5th percentile was the limit of normal). External validity was explored by comparison with the BRB-N. The new battery was also administered to a subsample after 4 weeks to assess reproducibility. RESULTS. To provide normative data, 1036 healthy subjects were recruited. The mean completion time was 18.5 ± 5.2 minutes. For the 229 subjects who were administered the new battery and the BRB-N, no statistically significant differences were found except for mean completion time (19 ± 4 vs 25 ± 5 minutes). In the reproducibility study, there were no significant differences except in the memory tests. CONCLUSION. The scores on the new battery and the BRB-N were strongly correlated although the shorter completion time and ease of administration could make the new battery preferable in clinical practice.

  11. Longevity of implantable cardioverter-defibrillators for cardiac resynchronization therapy in current clinical practice: an analysis according to influencing factors, device generation, and manufacturer.

    PubMed

    Landolina, Maurizio; Curnis, Antonio; Morani, Giovanni; Vado, Antonello; Ammendola, Ernesto; D'onofrio, Antonio; Stabile, Giuseppe; Crosato, Martino; Petracci, Barbara; Ceriotti, Carlo; Bontempi, Luca; Morosato, Martina; Ballari, Gian Paolo; Gasparini, Maurizio

    2015-08-01

    Device replacement at the time of battery depletion of implantable cardioverter-defibrillators (ICDs) may carry a considerable risk of complications and engenders costs for healthcare systems. Therefore, ICD device longevity is extremely important both from a clinical and economic standpoint. Cardiac resynchronization therapy defibrillators (CRT-D) battery longevity is shorter than ICDs. We determined the rate of replacements for battery depletion and we identified possible determinants of early depletion in a series of patients who had undergone implantation of CRT-D devices. We retrieved data on 1726 consecutive CRT-D systems implanted from January 2008 to March 2010 in nine centres. Five years after a successful CRT-D implantation procedure, 46% of devices were replaced due to battery depletion. The time to device replacement for battery depletion differed considerably among currently available CRT-D systems from different manufacturers, with rates of batteries still in service at 5 years ranging from 52 to 88% (log-rank test, P < 0.001). Left ventricular lead output and unipolar pacing configuration were independent determinants of early depletion [hazard ratio (HR): 1.96; 95% 95% confidence interval (CI): 1.57-2.46; P < 0.001 and HR: 1.58, 95% CI: 1.25-2.01; P < 0.001, respectively]. The implantation of a recent-generation device (HR: 0.57; 95% CI: 0.45-0.72; P < 0.001), the battery chemistry and the CRT-D manufacturer (HR: 0.64; 95% CI: 0.47-0.89; P = 0.008) were additional factors associated with replacement for battery depletion. The device longevity at 5 years was 54%. High left ventricular lead output and unipolar pacing configuration were associated with early battery depletion, while recent-generation CRT-Ds displayed better longevity. Significant differences emerged among currently available CRT-D systems from different manufacturers. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  12. Users manual for the Automated Performance Test System (APTS)

    NASA Technical Reports Server (NTRS)

    Lane, N. E.; Kennedy, R. S.

    1990-01-01

    The characteristics of and the user information for the Essex Automated Performance Test System (APTS) computer-based portable performance assessment battery are given. The battery was developed to provide a menu of performance test tapping the widest possible variety of human cognitive and motor functions, implemented on a portable computer system suitable for use in both laboratory and field settings for studying the effects of toxic agents and other stressors. The manual gives guidance in selecting, administering and scoring tests from the battery, and reviews the data and studies underlying the development of the battery. Its main emphasis is on the users of the battery - the scientists, researchers and technicians who wish to examine changes in human performance across time or as a function of changes in the conditions under which test data are obtained. First the how to information needed to make decisions about where and how to use the battery is given, followed by the research background supporting the battery development. Further, the development history of the battery focuses largely on the logical framework within which tests were evaluated.

  13. 2007 Nissan Altima-7982 Hybrid Electric Vehicle Battery Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Grey; Chester Motloch; James Francfort

    2010-01-01

    The U.S. Department of Energy's Advanced Vehicle Testing Activity conducts several different types of tests on hybrid electric vehicles, including testing hybrid electric vehicles batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of accelerated testing. This report documents the battery testing performed and battery testing results for the 2007 Nissan Altima hybrid electric vehicle (Vin Number 1N4CL21E27C177982). Testing was performed by the Electric Transportation Engineering Corporation. The Advanced Vehicle Testing Activity is part of the U.S. Department of Energy's Vehicle Technologies Program. The Idaho National Laboratory and the Electric Transportation Engineering Corporationmore » conduct Advanced Vehicle Testing Activity for the U.S. Department of Energy.« less

  14. Detection of capacity imbalance in vanadium electrolyte and its electrochemical regeneration for all-vanadium redox-flow batteries

    NASA Astrophysics Data System (ADS)

    Roznyatovskaya, Nataliya; Herr, Tatjana; Küttinger, Michael; Fühl, Matthias; Noack, Jens; Pinkwart, Karsten; Tübke, Jens

    2016-01-01

    A vanadium electrolyte for redox-flow batteries (VRFB) with different VIII and VIV mole fractions has been studied by UV-vis spectroscopy. Spectrophotometric detection enables a rough estimate of the VIV and VIII content, which can be used to detect an electrolyte capacity imbalance, i.e. a deviation in the mole fraction of VIV or VIII away from 50%. The isosbestic point at 600 nm can be used as a reference point in the analysis of common VRFB electrolyte batches. The VRFB electrolyte is observed to have an imbalance after prolonged storage (a couple of years) in a tank under ambient conditions. A regeneration procedure, which involves pre-charging the unbalanced electrolyte and mixing part of it with a portion of initial unbalanced electrolyte, has been tested. The resulting rebalanced electrolyte has been compared with a common electrolyte in a charge-discharge cell test and is shown to be suitable for cell operation.

  15. Life prediction and reliability assessment of lithium secondary batteries

    NASA Astrophysics Data System (ADS)

    Eom, Seung-Wook; Kim, Min-Kyu; Kim, Ick-Jun; Moon, Seong-In; Sun, Yang-Kook; Kim, Hyun-Soo

    Reliability assessment of lithium secondary batteries was mainly considered. Shape parameter (β) and scale parameter (η) were calculated from experimental data based on cycle life test. We also examined safety characteristics of lithium secondary batteries. As proposed by IEC 62133 (2002), we had performed all of the safety/abuse tests such as 'mechanical abuse tests', 'environmental abuse tests', 'electrical abuse tests'. This paper describes the cycle life of lithium secondary batteries, FMEA (failure modes and effects analysis) and the safety/abuse tests we had performed.

  16. Using a Standardized Clinical Quantitative Sensory Testing Battery to Judge the Clinical Relevance of Sensory Differences Between Adjacent Body Areas.

    PubMed

    Dimova, Violeta; Oertel, Bruno G; Lötsch, Jörn

    2017-01-01

    Skin sensitivity to sensory stimuli varies among different body areas. A standardized clinical quantitative sensory testing (QST) battery, established for the diagnosis of neuropathic pain, was used to assess whether the magnitude of differences between test sites reaches clinical significance. Ten different sensory QST measures derived from thermal and mechanical stimuli were obtained from 21 healthy volunteers (10 men) and used to create somatosensory profiles bilateral from the dorsum of the hands (the standard area for the assessment of normative values for the upper extremities as proposed by the German Research Network on Neuropathic Pain) and bilateral at volar forearms as a neighboring nonstandard area. The parameters obtained were statistically compared between test sites. Three of the 10 QST parameters differed significantly with respect to the "body area," that is, warmth detection, thermal sensory limen, and mechanical pain thresholds. After z-transformation and interpretation according to the QST battery's standard instructions, 22 abnormal values were obtained at the hand. Applying the same procedure to parameters assessed at the nonstandard site forearm, that is, z-transforming them to the reference values for the hand, 24 measurements values emerged as abnormal, which was not significantly different compared with the hand (P=0.4185). Sensory differences between neighboring body areas are statistically significant, reproducing prior knowledge. This has to be considered in scientific assessments where a small variation of the tested body areas may not be an option. However, the magnitude of these differences was below the difference in sensory parameters that is judged as abnormal, indicating a robustness of the QST instrument against protocol deviations with respect to the test area when using the method of comparison with a 95 % confidence interval of a reference dataset.

  17. Issues and Challenges Facing Flexible Lithium-Ion Batteries for Practical Application.

    PubMed

    Cha, Hyungyeon; Kim, Junhyeok; Lee, Yoonji; Cho, Jaephil; Park, Minjoon

    2017-12-27

    With the advent of flexible electronics, lithium-ion batteries have become a key component of high performance energy storage systems. Thus, considerable effort is made to keep up with the development of flexible lithium-ion batteries. To date, many researchers have studied newly designed batteries with flexibility, however, there are several significant challenges that need to be overcome, such as degradation of electrodes under external load, poor battery performance, and complicated cell preparation procedures. In addition, an in-depth understanding of the current challenges for flexible batteries is rarely addressed in a systematical and practical way. Herein, recent progress and current issues of flexible lithium-ion batteries in terms of battery materials and cell designs are reviewed. A critical overview of important issues and challenges for the practical application of flexible lithium-ion batteries is also provided. Finally, the strategies are discussed to overcome current limitations of the practical use of flexible lithium-based batteries, providing a direction for future research. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Miscoding and other user errors: importance of ongoing education for proper blood glucose monitoring procedures.

    PubMed

    Schrock, Linda E

    2008-07-01

    This article reviews the literature to date and reports on a new study that documented the frequency of manual code-requiring blood glucose (BG) meters that were miscoded at the time of the patient's initial appointment in a hospital-based outpatient diabetes education program. Between January 1 and May 31, 2007, the type of BG meter and the accuracy of the patient's meter code (if required) and procedure for checking BG were checked during the initial appointment with the outpatient diabetes educator. If indicated, reeducation regarding the procedure for the BG meter code entry and/or BG test was provided. Of the 65 patients who brought their meter requiring manual entry of a code number or code chip to the initial appointment, 16 (25%) were miscoded at the time of the appointment. Two additional problems, one of dead batteries and one of improperly stored test strips, were identified and corrected at the first appointment. These findings underscore the importance of checking the patient's BG meter code (if required) and procedure for testing BG at each encounter with a health care professional or providing the patient with a meter that does not require manual entry of a code number or chip to match the container of test strips (i.e., an autocode meter).

  19. Unified Tri-service Cognitive Performance Assessment Battery (UTC-PAB). Part 1: Design and specification of the battery

    NASA Astrophysics Data System (ADS)

    Englund, C. E.; Reeves, D. L.; Shingledecker, C. A.; Thorne, D. R.; Wilson, K. P.

    1987-02-01

    The Unified Tri-Service Cognitive Performance Assessment Battery (UTC-PAB) represents the primary metric for a Level 2 evaluation of cognitive performance in the JWGD3 MILPERF chemical defense biomedical drug screening program. Emphasis for UTC-PAB development has been on the standardization of test batteries across participating laboratories with respect to content, computer-based administration, test scoring, and data formatting. This effort has produced a 25-test UTC-PAB that represents the consolidation and unification of independent developments by the Tri-service membership. Test selection was based on established test validity and relevance of military performance. Sensitivity to effects of hostile environments and sustained operations were also considerations involved in test selection. Information processing, decision making, perception, and mental workload capacity are among the processes and abilities addressed in the battery. The UTC-PAB represents a dynamic approach to battery development. The nature of the biomedical drugs screened and information from performance centered task analyses will direct the form of future versions of the battery.

  20. [Redesign of the Spacesuit Long Life Battery and the Personal Life Support System Battery

    NASA Technical Reports Server (NTRS)

    Scharf, Stephanie

    2015-01-01

    This fall I was working on two different projects that culminated into a redesign of the spacesuit LLB (long life battery). I also did some work on the PLSS (personal life support system) battery with EC. My first project was redlining the work instruction for completing DPAs (destructive physical analysis) on battery cells in the department. The purpose of this document is to create a standard process and ensure that the data in the same way no matter who carries out the analysis. I observed three DPAs, conducted one with help, and conducted two on my own all while taking notes on the procedure. These notes were used to write the final work instruction that will become is the department standard. My second project continued the work of the summer co-op before me. I was testing aluminum heat sinks for their ability to provide good thermal conduction and structural support during a thermal runaway event. The heat sinks were designed by the summer intern but there was not much time for testing before he left. We ran tests with a heater on the bottom of a trigger cell to try to drive thermal runaway and ensure that it will not propagate to adjacent cells. We also ran heat-to-vent tests in an oven to see if the assembly provided structural support and prevented sidewall rupture during thermal runaway. These tests were carried out at ESTA (energy systems test area) and are providing very promising results that safe, high performing (greater than 180 Wh/kg) designs are possible. My main project was a redesign of the LLB battery. Another summer intern did some testing and concluded that there was no simple fix to mitigate thermal runaway propagation hazards in the current design. The only option was a clean sheet redesign of the battery. I was given a volume and ideal energy density and the rest of the design was up to me. First, I created new heat sink banks in Creo using the information gathered in the metal heat sink tests from the summer intern. After this, I made capture plates to hold the cells in place and I worked on nickel bussings for the electrical connections between the cells. Finally, I designed the test box enclosure that included sections for flame arresting materials. The battery brick design, which is the heart of the battery, promises to become the first for a manned spacecraft application to achieve greater than 180 Wh/kg. My work in redlining the DPA work instructions will also be used in selecting the cells for the battery. We had a few options of cells that would provide the necessary power output and needed to make a choice. We repeatedly charged and discharged cells for around a month until they went through 100 lifecycles. The plan is to compare the DPA results on fresh and cycled cells from each manufacturer to see if cycling introduces any differences. After the complete LLB design was approved, the parts were ordered and testing should begin the first week of December. Some of my side projects included working on the CAD data for the PLSS with EC and attending the NASA Aerospace Battery Workshop in Huntsville. I was also a member of the Tours and Lectures Committee for the USRA and Pathways interns. I coordinated Apollo Evening and was on the committee for touring KSC and seeing an Atlas 5 launch. I really enjoyed my time at JSC and I would like to continue working for NASA or another aerospace company in the future. I have worked other internships prior to this, but I think the heavy research and development focus is the best fit for me. I originally thought I would need to go to grad school to work in an environment like this, but I now see it is possible with a bachelor’s degree and hard work. I would like to go into the workforce and maybe continue my education with night classes.

  1. Charge Efficiency Tests of Lead/Acid Batteries

    NASA Technical Reports Server (NTRS)

    Rowlette, J. J.

    1984-01-01

    Current, voltage, and gas evolution measured during charge/discharge cycles. Series of standarized tests for evaluating charging efficiency of lead/acid storage batteries described in report. Purpose of tests to provide information for design of battery charger that allows maximum recharge efficiency for electric-vehicle batteries consistent with other operating parameters, such as range, water loss, and cycle life.

  2. The Danish test battery for auditory processing disorder evaluated with patient and control data.

    PubMed

    Raben Pedersen, Ellen

    2018-06-10

    This study evaluates the Danish test battery for auditory processing disorder (APD). The battery consists of four behavioural tests, two speech and two non-speech stimuli tests. The evaluation includes determination of: (1) new cut-off values (pass-fail criteria), (2) the sensitivity and the specificity of the entire test battery and (3) the failure rate of different test combinations. For each test in the battery, cut-off values were determined using the weighted Youden index. Applying the newly derived cut-off values, the distribution of failing specific test combinations was determined. A group of 112 children diagnosed with APD (57 boys, 55 girls, aged 6-16 years) and a control group containing 158 children without auditory problems (75 boys, 83 girls, aged 6-16 years). Cut-off values for different weights of the sensitivity and the specificity have been determined. Using the criterion that at least two tests have to be failed for APD to be suspected, the sensitivity and the specificity of the entire test battery were 95.3% and 91.6%, respectively. Some test combinations were found to have higher failure rates than others. Due to the high sensitivity and specificity the test battery has good predictive value in APD assessment.

  3. Atomic Layer Deposition of Metal Oxides on sp2-Graphitic Carbon Substrates

    DTIC Science & Technology

    2014-03-31

    supercapacitors . The research explored the ALD nucleation procedure based on NO2 and TMA. Al2O3 ALD films resulting from the nucleation procedure were...TiO2 and ZnO were used for electrodes for Li ion batteries and pseudocapacitance supercapacitors . 15. SUBJECT TERMS F-16 Aircraft, High Power...sp2 Graphitic Carbon Substrates 11 4.4.1 TiO2 ALD as Anode Material for Li Ion Batteries 11 4.4.2 TiO2 ALD for Pseudocapacitance Supercapacitors

  4. Determination of the heat capacities of Lithium/BCX (bromide chloride in thionyl chloride) batteries

    NASA Technical Reports Server (NTRS)

    Kubow, Stephen A.; Takeuchi, Kenneth J.; Takeuchi, Esther S.

    1989-01-01

    Heat capacities of twelve different Lithium/BCX (BrCl in thionyl chloride) batteries in sizes AA, C, D, and DD were determined. Procedures and measurement results are reported. The procedure allowed simple, reproducible, and precise determinations of heat capacities of industrially important Lithium/BCX cells, without interfering with performance of the cells. Use of aluminum standards allowed the accuracy of the measurements to be maintained. The measured heat capacities were within 5 percent of calculated heat capacity values.

  5. Study of oxygen gas production phenomenon during stand and discharge in silver-zinc batteries

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The effects of a number of cell process and performance variables upon the oxygen evolution rate of silver/silver oxide cathodes are studied to predict and measure the conditions which would result in the production of a minimum of oxygen. The following five tasks comprise the study: the design and fabrication of two pilot test cells to be used for electrode testing; the determination of the sensitivity and accuracy of the test cell; the determination of total volumes and rates of generation by cathodes of standard production procedures; the construction of a sequential test plan; and the construction of a series of positive formation cells in which formation process factors can be controlled.

  6. Examining procedural working memory processing in obsessive-compulsive disorder.

    PubMed

    Shahar, Nitzan; Teodorescu, Andrei R; Anholt, Gideon E; Karmon-Presser, Anat; Meiran, Nachshon

    2017-07-01

    Previous research has suggested that a deficit in working memory might underlie the difficulty of obsessive-compulsive disorder (OCD) patients to control their thoughts and actions. However, a recent meta-analyses found only small effect sizes for working memory deficits in OCD. Recently, a distinction has been made between declarative and procedural working memory. Working memory in OCD was tested mostly using declarative measurements. However, OCD symptoms typically concerns actions, making procedural working-memory more relevant. Here, we tested the operation of procedural working memory in OCD. Participants with OCD and healthy controls performed a battery of choice reaction tasks under high and low procedural working memory demands. Reaction-times (RT) were estimated using ex-Gaussian distribution fitting, revealing no group differences in the size of the RT distribution tail (i.e., τ parameter), known to be sensitive to procedural working memory manipulations. Group differences, unrelated to working memory manipulations, were found in the leading-edge of the RT distribution and analyzed using a two-stage evidence accumulation model. Modeling results suggested that perceptual difficulties might underlie the current group differences. In conclusion, our results suggest that procedural working-memory processing is most likely intact in OCD, and raise a novel, yet untested assumption regarding perceptual deficits in OCD. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  7. Reserve Li/SOC12 Battery Safety Testing

    NASA Technical Reports Server (NTRS)

    Dils, C. T.; Garoutte, K. F.

    1984-01-01

    A reserve Lithium/Thionyl Chloride Battery concept is developed and undergoing feasibility testing in terms of performance, safety and abusive conditions. The feasibility of employing a battery of this type to replace thermal batteries in certain applications is demonstrated. Excellent performance of a Li/SOCl2 reserve battery is obtained across the temperature range from 0 C to +44 C. Performance improvement over the thermal battery usage is greater by a factor of 3 when discharge time and energy density are compared. Performance over an expanded temperature range is also possible. Safety and abusive testing is accomplished successfully on a series of five units. Further performance improvements can be achieved with regard to battery weight and volume reductions.

  8. Crane Cell Testing Support of Nasa/goddard Space Flight Center: an Update

    NASA Technical Reports Server (NTRS)

    Strawn, Mike; David, Jerry; Rao, Gopalakrishna M.

    2001-01-01

    The objective of this paper is to verify the quality and reliability of aerospace battery cells and batteries for NASA flight programs, disseminate the data - to develop a plan for in-orbit battery management - to design a cell/battery for future NASA spacecraft and establish a cell test data base for rechargeable cell/batteries.

  9. [ALPHA-fitness test battery: health-related field-based fitness tests assessment in children and adolescents].

    PubMed

    Ruiz, J R; España Romero, V; Castro Piñero, J; Artero, E G; Ortega, F B; Cuenca García, M; Jiménez Pavón, D; Chillón, P; Girela Rejón, Ma J; Mora, J; Gutiérrez, A; Suni, J; Sjöstrom, M; Castillo, M J

    2011-01-01

    Hereby we summarize the work developed by the ALPHA (Assessing Levels of Physical Activity) Study and describe the tests included in the ALPHA health-related fitness test battery for children and adolescents. The evidence-based ALPHA-Fitness test battery include the following tests: 1) the 20 m shuttle run test to assess cardiorespiratory fitness; 2) the handgrip strength and 3) standing broad jump to assess musculoskeletal fitness, and 4) body mass index, 5) waist circumference; and 6) skinfold thickness (triceps and subscapular) to assess body composition. Furthermore, we include two versions: 1) the high priority ALPHA health-related fitness test battery, which comprises all the evidence-based fitness tests except the measurement of the skinfold thickness; and 2) the extended ALPHA health-related fitness tests battery for children and adolescents, which includes all the evidence-based fitness tests plus the 4 x 10 m shuttle run test to assess motor fitness.

  10. Making sense of listening: the IMAP test battery.

    PubMed

    Barry, Johanna G; Ferguson, Melanie A; Moore, David R

    2010-10-11

    The ability to hear is only the first step towards making sense of the range of information contained in an auditory signal. Of equal importance are the abilities to extract and use the information encoded in the auditory signal. We refer to these as listening skills (or auditory processing AP). Deficits in these skills are associated with delayed language and literacy development, though the nature of the relevant deficits and their causal connection with these delays is hotly debated. When a child is referred to a health professional with normal hearing and unexplained difficulties in listening, or associated delays in language or literacy development, they should ideally be assessed with a combination of psychoacoustic (AP) tests, suitable for children and for use in a clinic, together with cognitive tests to measure attention, working memory, IQ, and language skills. Such a detailed examination needs to be relatively short and within the technical capability of any suitably qualified professional. Current tests for the presence of AP deficits tend to be poorly constructed and inadequately validated within the normal population. They have little or no reference to the presenting symptoms of the child, and typically include a linguistic component. Poor performance may thus reflect problems with language rather than with AP. To assist in the assessment of children with listening difficulties, pediatric audiologists need a single, standardized child-appropriate test battery based on the use of language-free stimuli. We present the IMAP test battery which was developed at the MRC Institute of Hearing Research to supplement tests currently used to investigate cases of suspected AP deficits. IMAP assesses a range of relevant auditory and cognitive skills and takes about one hour to complete. It has been standardized in 1500 normally-hearing children from across the UK, aged 6-11 years. Since its development, it has been successfully used in a number of large scale studies both in the UK and the USA. IMAP provides measures for separating out sensory from cognitive contributions to hearing. It further limits confounds due to procedural effects by presenting tests in a child-friendly game-format. Stimulus-generation, management of test protocols and control of test presentation is mediated by the IHR-STAR software platform. This provides a standardized methodology for a range of applications and ensures replicable procedures across testers. IHR-STAR provides a flexible, user-programmable environment that currently has additional applications for hearing screening, mapping cochlear implant electrodes, and academic research or teaching.

  11. A menu of self-administered microcomputer-based neurotoxicology tests

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Wilkes, Robert L.; Kuntz, Lois-Ann; Baltzley, Dennis R.

    1988-01-01

    This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests. Researchers developed this battery to be used to screen the fitness for duty of persons in at-risk occupations (astronauts, race car drivers), or those who may be exposed to environmental stress, toxic agents, or disease. The menu under study contained cognitive and motor tests implemented on a portable microcomputer including: a five-test core battery, lasting six minutes, which had demonstrable reliabilities and stability from several previous repeated-measures studies, and also 13 new tests, lasting 42 minutes, which had appeared in other batteries but had not yet been evaluated for repeated-measures implementation in this medium. Sixteen subjects self-administered the battery over 10 repeated sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the test from the core battery were comparable to those obtained previously under more controlled experimental conditions. Analyses of metric properties of the remaining 13 tests produced eight additional tests with satisfactory properties. Although the average retest reliability was high, cross-correlations between tests were low, indicating factorial richness. The menu can be used to form batteries of flexible total testing time which are likely to tap different mental processes and functions.

  12. Glossary of testing terminology for rechargeable batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, P.C.

    1988-10-01

    The Battery Test Working Task Force was formed in 1983 for the purpose of coordinating the evaluation of development rechargeable batteries by DOE-funded labs. The Task Force developed this glossary of testing terminology to improve the accuracy of communication and to permit meaningful comparisons of test results. It consists of a section of technical terms and a separate section of programmatic phrases and acronyms. The glossary emphasizes terms related to electric vehicle batteries due to the significant development and testing activities in this area. 8 refs.

  13. The 1988 Goddard Space Flight Center Battery Workshop

    NASA Technical Reports Server (NTRS)

    Yi, Thomas Y. (Editor)

    1993-01-01

    This document contains the proceedings of the 21st annual Battery Workshop held at Goddard Space Flight Center, Greenbelt, Maryland on November 1-3, 1988. The Workshop attendees included manufacturers, users, and government representatives interested in the latest developments in battery technology as they relate to high reliability operations and aerospace use. The subjects covered included battery testing methodologies and criteria, life testing of nickel-cadmium cells, testing and operation of nickel-hydrogen batteries in low earth orbit, and nickel-hydrogen technology issues and concerns.

  14. Investigations of metal leaching from mobile phone parts using TCLP and WET methods.

    PubMed

    Yadav, Satyamanyu; Yadav, Sudesh

    2014-11-01

    Metal leaching from landfills containing end-of-life or otherwise discarded mobile phones poses a threat to the environment as well as public health. In the present study, the metal toxicity of printed wire boards (PWBs), plastics, liquid crystal displays (LCDs) and batteries of mobile phones was assessed using the Toxicity Characteristics Leaching Procedures (TCLP) and the Waste Extraction Test (WET). The PWBs failed TCLP for Pb and Se, and WET for Pb and Zn. In WET, the two PWB samples for Pb and Zn and the battery samples for Co and Cu failed the test. Furthermore, the PWBS for Ni and the battery samples for Ni and Co failed the WET in their TCLP leachates. Both, Ni and Co are the regulatory metals in only WET and not covered under TCLP. These observations indicate that the TCLP seems to be a more aggressive test than the WET for the metal leaching from the mobile phone parts. The compositional variations, nature of leaching solution (acetate in TCLP and citrate in WET) and the redox conditions in the leaching solution of the PWBs resulted in different order of metals with respect to their amounts of leaching from PWBs in TCLP (Fe > Pb > Zn > Ni > Co > Cu) and WET (Zn > Fe > Ni > Pb > Cu). The metal leaching also varied with the make, manufacturing year and part of the mobile phone tested. PWBs, plastics and batteries should be treated as hazardous waste. Metal leaching, particularly of Se and Pb, from mobile phones can be harmful to the environment and human health. Therefore, a scientifically sound and environmentally safe handling and disposal management system needs to be evolved for the mobile phone disposal. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Nonleaking battery terminals

    NASA Technical Reports Server (NTRS)

    Snider, W. E.; Nagle, W. J.

    1972-01-01

    Three different terminals were designed for usage in a 40 ampere/hour silver zinc battery which has a 45 percent KOH by weight electrolyte in a plastic battery case. Life tests, including thermal cycling, electrical charge and discharge for up to three years duration, were conducted on these three different terminal designs. Tests for creep rate and tensile strength were conducted on the polyphenylene oxide (PPO) plastic battery cases. Some cases were unused and others containing KOH electrolyte were placed on life tests. The design and testing of nonleaking battery terminals for use with a potassium hydroxide (KOH) electrolyte in a plastic case are discussed.

  16. Nonleaking battery terminals.

    NASA Technical Reports Server (NTRS)

    Snider, W. E.; Nagle, W. J.

    1972-01-01

    Three different terminals were designed for usage in a 40 ampere/hour silver zinc battery which has a 45% KOH by weight electrolyte in a plastic battery case. Life tests, including thermal cycling, electrical charge and discharge for up to three years duration, were conducted on these three different terminal designs. Tests for creep rate and tensile strength were conducted on the polyphenylene oxide plastic battery cases. Some cases were unused and others containing KOH electrolyte were placed on life tests. The design and testing of nonleaking battery terminals for use with a KOH electrolyte in a plastic case are considered.

  17. Equipment for testing automotive lead/acid batteries under SAE J240a conditions

    NASA Astrophysics Data System (ADS)

    Hamilton, J. A.; Rand, D. A. J.

    Battery cycling equipment has been designed and constructed to test lead/acid batteries according to the American Society of Automotive Engineers' (SAE) J240a Standard. This life test simulates automotive service where the battery operates in a voltage-regulated charging system. The CSIRO design uses a master/slave concept to reduce both construction time and cost.

  18. Open stack thermal battery tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Kevin N.; Roberts, Christine C.; Grillet, Anne M.

    We present selected results from a series of Open Stack thermal battery tests performed in FY14 and FY15 and discuss our findings. These tests were meant to provide validation data for the comprehensive thermal battery simulation tools currently under development in Sierra/Aria under known conditions compared with as-manufactured batteries. We are able to satisfy this original objective in the present study for some test conditions. Measurements from each test include: nominal stack pressure (axial stress) vs. time in the cold state and during battery ignition, battery voltage vs. time against a prescribed current draw with periodic pulses, and images transversemore » to the battery axis from which cell displacements are computed. Six battery configurations were evaluated: 3, 5, and 10 cell stacks sandwiched between 4 layers of the materials used for axial thermal insulation, either Fiberfrax Board or MinK. In addition to the results from 3, 5, and 10 cell stacks with either in-line Fiberfrax Board or MinK insulation, a series of cell-free “control” tests were performed that show the inherent settling and stress relaxation based on the interaction between the insulation and heat pellets alone.« less

  19. The UltraBattery-A new battery design for a new beginning in hybrid electric vehicle energy storage

    NASA Astrophysics Data System (ADS)

    Cooper, A.; Furakawa, J.; Lam, L.; Kellaway, M.

    The UltraBattery, developed by CSIRO Energy Technology in Australia, is a hybrid energy storage device which combines an asymmetric super-capacitor and a lead-acid battery in single unit cells. This takes the best from both technologies without the need for extra, expensive electronic controls. The capacitor enhances the power and lifespan of the lead-acid battery as it acts as a buffer during high-rate discharging and charging, thus enabling it to provide and absorb charge rapidly during vehicle acceleration and braking. The initial performance of the prototype UltraBatteries was evaluated according to the US FreedomCAR targets and was shown to meet or exceed these in terms of power, available energy, cold cranking and self-discharge set for both minimum and maximum power-assist hybrid electric vehicles (HEVs). Other laboratory cycling tests showed a fourfold improvement over previous state-of-the-art lead-acid batteries under the RHOLAB test profile and better life than commercial nickel/metal hydride (NiMH) cells used in a Honda Insight when tested under the EUCAR HEV profile. As a result of this work, a set of twelve 12 V modules was built by The Furukawa Battery Co., Ltd. in Japan and were fitted into a Honda Insight instead of the NiMH battery by Provector Ltd. The battery pack was fitted with full monitoring and control capabilities and the car was tested at Millbrook Proving Ground under a General Motors road test simulation cycle for an initial target of 50 000 miles which was extended to 100 000 miles. This was completed on 15th January 2008 without any battery problems. Furthermore, the whole test was completed without the need for any conditioning or equalisation of the battery pack.

  20. Selecting At-Risk First-Grade Readers for Early Intervention: Eliminating False Positives and Exploring the Promise of a Two-Stage Gated Screening Process

    ERIC Educational Resources Information Center

    Compton, Donald L.; Fuchs, Douglas; Fuchs, Lynn S.; Bouton, Bobette; Gilbert, Jennifer K.; Barquero, Laura A.; Cho, Eunsoo; Crouch, Robert C.

    2010-01-01

    The purposes of this study were (a) to identify measures that when added to a base 1st-grade screening battery help eliminate false positives and (b) to investigate gains in efficiency associated with a 2-stage gated screening procedure. We tested 355 children in the fall of 1st grade and assessed for reading difficulty at the end of 2nd grade.…

  1. Data pieces-based parameter identification for lithium-ion battery

    NASA Astrophysics Data System (ADS)

    Gao, Wei; Zou, Yuan; Sun, Fengchun; Hu, Xiaosong; Yu, Yang; Feng, Sen

    2016-10-01

    Battery characteristics vary with temperature and aging, it is necessary to identify battery parameters periodically for electric vehicles to ensure reliable State-of-Charge (SoC) estimation, battery equalization and safe operation. Aiming for on-board applications, this paper proposes a data pieces-based parameter identification (DPPI) method to identify comprehensive battery parameters including capacity, OCV (open circuit voltage)-Ah relationship and impedance-Ah relationship simultaneously only based on battery operation data. First a vehicle field test was conducted and battery operation data was recorded, then the DPPI method is elaborated based on vehicle test data, parameters of all 97 cells of the battery package are identified and compared. To evaluate the adaptability of the proposed DPPI method, it is used to identify battery parameters of different aging levels and different temperatures based on battery aging experiment data. Then a concept of ;OCV-Ah aging database; is proposed, based on which battery capacity can be identified even though the battery was never fully charged or discharged. Finally, to further examine the effectiveness of the identified battery parameters, they are used to perform SoC estimation for the test vehicle with adaptive extended Kalman filter (AEKF). The result shows good accuracy and reliability.

  2. Value-based decision-making battery: A Bayesian adaptive approach to assess impulsive and risky behavior.

    PubMed

    Pooseh, Shakoor; Bernhardt, Nadine; Guevara, Alvaro; Huys, Quentin J M; Smolka, Michael N

    2018-02-01

    Using simple mathematical models of choice behavior, we present a Bayesian adaptive algorithm to assess measures of impulsive and risky decision making. Practically, these measures are characterized by discounting rates and are used to classify individuals or population groups, to distinguish unhealthy behavior, and to predict developmental courses. However, a constant demand for improved tools to assess these constructs remains unanswered. The algorithm is based on trial-by-trial observations. At each step, a choice is made between immediate (certain) and delayed (risky) options. Then the current parameter estimates are updated by the likelihood of observing the choice, and the next offers are provided from the indifference point, so that they will acquire the most informative data based on the current parameter estimates. The procedure continues for a certain number of trials in order to reach a stable estimation. The algorithm is discussed in detail for the delay discounting case, and results from decision making under risk for gains, losses, and mixed prospects are also provided. Simulated experiments using prescribed parameter values were performed to justify the algorithm in terms of the reproducibility of its parameters for individual assessments, and to test the reliability of the estimation procedure in a group-level analysis. The algorithm was implemented as an experimental battery to measure temporal and probability discounting rates together with loss aversion, and was tested on a healthy participant sample.

  3. Nickel-cadium batteries for Apollo telescope mount

    NASA Technical Reports Server (NTRS)

    Kirsch, W. W.; Shikoh, A. E.

    1974-01-01

    The operational testing and evaluation program is presented which was conducted on 20-ampere-hour nickel-cadmium (Ni-Cd) batteries for use on the Apollo telescope mount (ATM). The test program was initiated in 1967 to determine if the batteries could meet ATM mission requirements and to determine operating characteristics and methods. The ATM system power and charging power for the Ni-Cd secondary batteries is provided by a solar array during the 58-minute daylight portion of the orbit; during the 36-minute night portion of the orbit, the Ni-Cd secondary batteries will supply ATM system power. The test results reflect battery operating characteristics and parameters relative to simulated ATM orbital test conditions. Maximum voltage, charge requirements, capacity, temperature, and cyclic characteristics are presented.

  4. A Path to an Instructional Science: Data-Generated vs. Postulated Models

    ERIC Educational Resources Information Center

    Gropper, George L.

    2016-01-01

    Psychological testing can serve as a prototype on which to base a data-generated approach to instructional design. In "testing batteries" tests are used to predict achievement. In the proposed approach batteries of prescriptions would be used to produce achievement. In creating "test batteries" tests are selected for their…

  5. Evaluation program for secondary spacecraft cells: Cycle life test

    NASA Technical Reports Server (NTRS)

    Harkness, J. D.

    1979-01-01

    The service life and storage stability for several storage batteries were determined. The batteries included silver-zinc batteries, nickel-cadmium batteries, and silver-cadmium batteries. The cell performance characteristics and limitations are to be used by spacecraft power systems planners and designers. A statistical analysis of the life cycle prediction and cause of failure versus test conditions is presented.

  6. Space Technology-5 Lithium-Ion Battery Design, Qualification and Integration and Testing

    NASA Technical Reports Server (NTRS)

    Rao, Gopalakishna M.; Stewart, Karen; Ameen, Syed; Banfield, Peter K.

    2005-01-01

    This document is a viewgraph presentation that reviews the Lithium Ion Battery for the Space Technology-5 (ST-5) mission. Included in the document is a review of the ST-5 Mission, a review of the battery requirements, a description of the battery and the battery materials. The testing and the integration and qualification data is reviewed.

  7. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis & Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during FY-92 on both single cells and multi-cell modules that encompass six battery technologies (Na/S, Li/FeS, Ni/Metal-Hydride, Ni/Zn, Ni/Cd, Ni/Fe). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.

  8. Development of a Valid Volleyball Skills Test Battery.

    ERIC Educational Resources Information Center

    Bartlett, Jackie; And Others

    1991-01-01

    Describes the development of the North Carolina State University Volleyball Skills Test Battery which offers accurate measurement of three volleyball skills (serve, forearm pass, and set). When physical educators tested 313 students, the battery objectively measured their abilities, providing a gamelike means of teaching, testing, grouping, and…

  9. Li-Ion Battery Studies at NASA/Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Lee, Leonine; Rao, Gopalakrishna M.

    2006-01-01

    This viewgraph presentation reviews NASA and GSFC's interest in Lithium Ion Batteries as power suupplies for space usage, the tests, and results on several commercially available batteries. Severl batteries were tested for Geosynchronous orbit, Low Earth Orbit, and Low Lunar Orbit conditions.

  10. Accelerated battery-life testing - A concept

    NASA Technical Reports Server (NTRS)

    Mccallum, J.; Thomas, R. E.

    1971-01-01

    Test program, employing empirical, statistical and physical methods, determines service life and failure probabilities of electrochemical cells and batteries, and is applicable to testing mechanical, electrical, and chemical devices. Data obtained aids long-term performance prediction of battery or cell.

  11. Lithium-ion batteries for hearing aid applications. II. Pulse discharge and safety tests

    NASA Astrophysics Data System (ADS)

    Passerini, S.; Coustier, F.; Owens, B. B.

    Rechargeable lithium-ion batteries were designed to meet the power requirements of hearing aid devices (HADs). The batteries were designed in a 312-button cell size, compatible with existing hearing aids. The batteries were tested to evaluate the design and the electrochemical performance, as they relate to a typical hearing aid application. The present report covers the pulse capabilities, cycle life and preliminary safety tests. The results are compared with other battery chemistries: secondary lithium-alloy and nickel-metal hydride batteries and primary Zn-air batteries. The cell AC impedance was stable over the frequency range between 1 and 50 kHz, ranging between 5 Ω at the higher frequency and 12 Ω at the lower extreme. Pulse tests were consistent with these values, as the cells were capable of providing a series of 100 mA pulses of 10-s duration. The safety tests suggest that the design is intrinsically safe with respect to the most common types of abuse conditions.

  12. Special Test Methods for Batteries

    NASA Technical Reports Server (NTRS)

    Gross, S.

    1984-01-01

    Various methods are described for measuring heat generation in primary and secondary batteries as well as the specific heat of batteries and cell thermal conductance. Problems associated with determining heat generation in large batteries are examined. Special attention is given to monitoring temperature gradients in nickel cadmium cells, the use of auxiliary electrodes for conducting tests on battery charge control, evaluating the linear sweep of current from charge to discharge, and determining zero current voltage. The fast transient behavior of batteries in the microsecond range, and the electrical conductance of nickel sinters in the thickness direction are also considered. Mechanical problems experienced in the vibration of Ni-Cd batteries and tests to simulate cyclic fatigue of the steel table connecting the plates to the comb are considered. Methods of defining the distribution of forces when cells are compressed during battery packaging are also explored.

  13. Special test methods for batteries

    NASA Astrophysics Data System (ADS)

    Gross, S.

    1984-09-01

    Various methods are described for measuring heat generation in primary and secondary batteries as well as the specific heat of batteries and cell thermal conductance. Problems associated with determining heat generation in large batteries are examined. Special attention is given to monitoring temperature gradients in nickel cadmium cells, the use of auxiliary electrodes for conducting tests on battery charge control, evaluating the linear sweep of current from charge to discharge, and determining zero current voltage. The fast transient behavior of batteries in the microsecond range, and the electrical conductance of nickel sinters in the thickness direction are also considered. Mechanical problems experienced in the vibration of Ni-Cd batteries and tests to simulate cyclic fatigue of the steel table connecting the plates to the comb are considered. Methods of defining the distribution of forces when cells are compressed during battery packaging are also explored.

  14. The electrical performance of Ag Zn batteries for the Venus multi-probe mission

    NASA Technical Reports Server (NTRS)

    Palandati, C.

    1975-01-01

    An evaluation of 5 Ah and 21 Ah Silver-Zinc batteries was made to determine their suitability to meet the energy storage requirements of the bus vehicle, 3 small probes and large probe for the Venus multi-probe mission. The evaluation included a 4 Ah battery for the small probe, a 21 Ah battery for the large probe, one battery of each size for the bus vehicle power, a periodic cycling test on each size battery and a wet stand test of charged and discharged cells of both cell designs. The study on the probe batteries and bus vehicle batteries included both electrical and thermal simulation for the entire mission. The effects on silver migration and zinc penetration of the cellophane separators caused by the various test parameters were determined by visual and X-ray fluorescence analysis. The 5 Ah batteries supported the power requirements for the bus vehicle and small probe. The 21 Ah large probe battery supplied the required mission power. Both probe batteries delivered in excess of 132 percent of rated capacity at the completion of the mission simulation.

  15. An evaluation of the hemiplegic subject based on the Bobath approach. Part III. A validation study.

    PubMed

    Arsenault, A B; Dutil, E; Lambert, J; Corriveau, H; Guarna, F; Drouin, G

    1988-01-01

    Sixty-two hemiplegic subjects were treated with the Bobath approach for a period of three months. During this time they were evaluated on three occasions. The testing battery consisted of a Bobath evaluation, the Brunnstrom scale, the Fugl-Meyer test, the Upper Extremity Functional Test (UEFT) and the Present Pain Intensity (PPI) of the McGill pain questionnaire. A Friedman analysis of variance showed that, except for pain, all the protocols used disclosed significant progress (p less than 0.001) over time in terms of motor recovery. Except for pain, the results of the Bobath evaluation were significantly correlated (Spearman's Rho, p less than 0.001) with the results of the other testing procedures. It is concluded that the new Bobath evaluation proposed in a previous paper is as sensitive in depicting progress in motor recovery over time as are the other testing procedures used. Furthermore, this new evaluation seems to be measuring similar properties to the other tests. However, pain (PPI) appears not to be an important dependent variable.

  16. Adapting large batteries of research measures for immigrants.

    PubMed

    Aroian, Karen J

    2013-06-01

    A four-step, streamlined process to adapt a large battery of measures for a study of mother-child adjustment in Arab Muslim immigrants and the lessons learned are described. The streamlined process includes adapting content, translation, pilot testing, and extensive psychometric evaluation but omits in-depth qualitative inquiry to identify the full content domain of the constructs of interest and cognitive interviews to assess how respondents interpret items. Lessons learned suggest that the streamlined process is not sufficient for certain measures, particularly when there is little published information about how the measure performs with different groups, the measure requires substantial item revision to achieve content equivalence, and the measure is both challenging to translate and has little to no redundancy. When these conditions are present, condition-specific procedures need to be added to the streamlined process.

  17. Cerebral specialization for speech perception and movement organization in adults with Down's syndrome.

    PubMed

    Elliott, D; Weeks, D J

    1993-03-01

    Adults with Down's syndrome and a group of undifferentiated mentally handicapped persons were examined using a free recall dichotic listening procedure to determine a laterality index for the perception of speech sounds. Subjects also performed both the visual and verbal portions of a standard apraxia battery. As in previous research, subjects with Down's syndrome tended to display a left ear advantage on the dichotic listening test. As well, they performed better on the apraxia battery when movements were cued visually rather than verbally. This verbal-motor disadvantage increased as the left ear dichotic listening advantage became more pronounced. It is argued that the verbal-motor difficulties experienced by persons with Down's syndrome stem from a dissociation of the functional systems responsible for speech perception and movement organization (Elliott and Weeks, 1990).

  18. Determination of the mechanical integrity of polyvinylidene difluoride in LiNi1/3Co1/3Mn1/3O2 electrodes for lithium ion batteries by use of the micro-indentation technique

    NASA Astrophysics Data System (ADS)

    Wendt, Christian; Niehoff, Philip; Winter, Martin; Schappacher, Falko M.

    2018-07-01

    Understanding the mechanical aging of lithium ion batteries influencing the binder stability is of particular interest for enhanced battery life. In this study we present an indentation method to investigate the changes in the elasticity of PVdF in NCM electrodes with high reproducibility. To determine changes in elasticity by calculating the indentation work (ηit), a 50 μm flat punch indenter was used. In addition, a drying procedure for DMC washed samples was evaluated to reduce the effect of the washing procedure on the elasticity due to swelling of the binder. NCM electrodes soaked with electrolyte and electrodes after formation were investigated, showing a significant decrease in elasticity due to the contact with the LiPF6 containing organic carbonate solvent based electrolyte and due to the electrochemical formation procedure. Further electrochemical aging reduced the elasticity to nearly ≈50% compared to the pristine electrode. Method development and the obtained results are discussed in detail. The developed method provides a low standard deviation and high reproducibility. Hence, it is a valid methodology for the quantification of related aging mechanisms taking place in lithium ion batteries.

  19. UHM/HNEI EV test and evaluation program

    NASA Astrophysics Data System (ADS)

    1992-03-01

    The electric vehicle (EV) program of the Hawaii Natural Energy Institute (HNEI) focuses primarily on the field testing of promising EV/traction batteries. The intent is to utilize typical driving cycles to develop information that verifies or refutes what is obtained in the laboratory. Three different types of batteries were assigned by the U.S. DOE for testing in this program: Sonnenschein Dryfit 6V-160, Exide GC-5, Trojan T-145. We added the following battery to the test program: ALCO2200. The following EVs were chosen in our program: Converted Ford Escort station wagon, Converted Ford Escort two-door sedan, Converted Ford Escort two-door sedan, Converted Dodge van. Based on capacity tests, corrective action such as battery replacement, additional charging, adjusting terminal connections, etc., may be taken to maintain good performance. About 15,500 miles and 600 cycles have been accumulated on the Sonnenschein Dryfit 6V-160 battery pack. Five of its 18 modules have been changed. Based on DOE's standard, the battery has reached the end of its useful life. Nevertheless, the battery pack is still operational and its operating range is still greater than 40 miles per charge. It is too early to evaluate the life expectancy of the other three batteries. No module has been replaced in these three packs. HNEI will keep the Trojan and Exide battery packs in operation. The Alco 2200 batteries will be transferred to another vehicle.

  20. An approach for Ewing test selection to support the clinical assessment of cardiac autonomic neuropathy.

    PubMed

    Stranieri, Andrew; Abawajy, Jemal; Kelarev, Andrei; Huda, Shamsul; Chowdhury, Morshed; Jelinek, Herbert F

    2013-07-01

    This article addresses the problem of determining optimal sequences of tests for the clinical assessment of cardiac autonomic neuropathy (CAN). We investigate the accuracy of using only one of the recommended Ewing tests to classify CAN and the additional accuracy obtained by adding the remaining tests of the Ewing battery. This is important as not all five Ewing tests can always be applied in each situation in practice. We used new and unique database of the diabetes screening research initiative project, which is more than ten times larger than the data set used by Ewing in his original investigation of CAN. We utilized decision trees and the optimal decision path finder (ODPF) procedure for identifying optimal sequences of tests. We present experimental results on the accuracy of using each one of the recommended Ewing tests to classify CAN and the additional accuracy that can be achieved by adding the remaining tests of the Ewing battery. We found the best sequences of tests for cost-function equal to the number of tests. The accuracies achieved by the initial segments of the optimal sequences for 2, 3 and 4 categories of CAN are 80.80, 91.33, 93.97 and 94.14, and respectively, 79.86, 89.29, 91.16 and 91.76, and 78.90, 86.21, 88.15 and 88.93. They show significant improvement compared to the sequence considered previously in the literature and the mathematical expectations of the accuracies of a random sequence of tests. The complete outcomes obtained for all subsets of the Ewing features are required for determining optimal sequences of tests for any cost-function with the use of the ODPF procedure. We have also found two most significant additional features that can increase the accuracy when some of the Ewing attributes cannot be obtained. The outcomes obtained can be used to determine the optimal sequences of tests for each individual cost-function by following the ODPF procedure. The results show that the best single Ewing test for diagnosing CAN is the deep breathing heart rate variation test. Optimal sequences found for the cost-function equal to the number of tests guarantee that the best accuracy is achieved after any number of tests and provide an improvement in comparison with the previous ordering of tests or a random sequence. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Hubble Space Telescope On-orbit NiH2 Battery Performance

    NASA Technical Reports Server (NTRS)

    Rao, Gopalakrishna M.; Krol, Stanley J., Jr.

    2002-01-01

    This paper summarizes the Hubble Space Telescope (HST) nickel-hydrogen (NiH2) battery performance from launch to the present time. Over the life of HST vehicle configuration, charge system degradation and failures together with thermal design limitations have had a significant effect on the capacity of the HST batteries. Changes made to the charge system configuration in order to protect against power system failures and to maintain battery thermal stability resulted in undercharging of the batteries. This undercharging resulted in decreased usable battery capacity as well as battery cell voltage/capacity divergence. This cell divergence was made evident during on-orbit battery capacity measurements by a relatively shallow slope of the discharge curve following the discharge knee. Early efforts to improve the battery performance have been successful. On-orbit capacity measurement data indicates increases in the usable battery capacity of all six batteries as well as improvements in the battery cell voltage/capacity divergence. Additional measures have been implemented to improve battery performance, however, failures within the HST Power Control Unit (PCU) have prevented verification of battery status. As this PCU fault prevents the execution of on-orbit capacity testing, the HST Project has based the battery capacity on trends, which utilizes previous on-orbit battery capacity test data, for science mission and servicing mission planning. The Servicing Mission 38 (SM-3B) in March 2002 replaced the faulty PCU. Following the servicing mission, on-orbit capacity test resumed. A summary of battery performance is reviewed since launch in this paper.

  2. Initial testing of two DEMI (Driesbach Electromotive Inc. ) Model 4E zinc-air rechargeable cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, J.E.; Martin, M.E.

    1989-10-23

    The purpose of this document is to report the results of INEL laboratory testing of two DEMI 4E Aerobic Power Battery Cells (collectively designated Pack 46 in INEL records). The 4E Aerobic Power Battery is a secondary battery developed privately by Driesbach Electromotive Inc. (DEMI). The battery employs zinc as the anode and a bifunctional air cathode. This testing was performed as the first phase of a cooperative agreement between INEL and DEMI leading to the construction and testing of electric vehicle-size cells, to be followed eventually by a battery pack. 3 refs., 3 figs., 5 tabs.

  3. Single potential electrodeposition of nanostructured battery materials for lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Mosby, James Matthew

    The increasing reliance on portable electronics is continuing to fuel research in the area of low power lithium-ion batteries, while a new surge in research for high power lithium-ion batteries has been sparked by the demand for plug-in hybrid electric vehicles (PHEV) and plug-in electric vehicles (PEV). To compete with current lead-acid battery chemistry, a few of the shortcomings of lithium-ion battery chemistry need to be addressed. The three main drawbacks of lithium-ion batteries for this application are: (1) low power density, (2) safety, and (3) the high cost of manufacturing. This dissertation covers the development of a low cost fabrication technique for an alternative anode material with high surface area geometries. The anode material is safer than the conventional anode material in lithium-ion batteries and the high surface area geometries permit higher power densities to be achieved. Electrodeposition is an inexpensive alternative method for synthesizing materials for electronics, energy conversion and energy storage applications relative to traditional solid state techniques. These techniques led to expensive device fabrication. Unlike most solid state synthesis routes, electrodeposition can usually be performed from common solutions and at moderate conditions. Three other benefits of using electrodeposition are: (1) it allows precise control of composition and crystallinity, (2) it provides the ability to deposit on complex shapes, and (3) it can deposit materials with nanoscale dimensions. The use of electrodeposition for alternative anode materials results in the deposition of the material directly onto the current collector that is used for the battery testing and applications without the need of additional binders and with excellent electrical contact. While this improves the characterization of the material and lowers the weight of the non-active materials within a battery, it also allows the anode to be deposited onto current collectors with different sizes, shapes, and surface areas. This is advantageous because high surface area materials benefit from improved kinetics for solid state transformations and from decreases in mechanical degradation that occurs during the lithiation and delithiation of battery materials. Intermetallic materials are an alternative to conventional anode materials because they have high capacities and react reversibly with lithium at potentials that hinder the dendrite formation of metallic lithium. Unfortunately, the volume expansion associated with the lithiation and delithiation of intermetallic materials is usually large (over 300%). With this in mind a procedure for the electrodeposition of Cu2Sb from aqueous solutions was developed and is presented in this thesis. Cu2Sb is an intermetallic that lithiates at potentials more positive than the potential needed to plate lithium metal, and has a volume expansion less than 100%. Electrodeposition of an intermetallic with a relatively small volume expansion and with high surface area morphology should dramatically reduce material degradation during battery cycling, thus promoting the life of the material. To electrodeposit Cu2Sb from aqueous solutions, soluble salts of Cu2+ and Sb3+ were needed. There are many Cu2+ salts that are highly soluble in water, but most Sb 3+ salts cause formation of Sb2O3 in aqueous solutions. To obtain Sb3+ in aqueous solutions, citric acid was used as a complexing agent. The results presented in this dissertation show that solution speciation plays an important role in the electrochemistry of aqueous citrate solutions of both copper and antimony. The cyclic voltammograms (CVs) presented here show that the reduction potential of Cu2+ shifted in the negative direction and the reduction potential of Sb 3+ shifted in the positive direction with an increase in pH. Also, Cu2Sb films were deposited at a single potential (-1050 mV vs. SSCE) from aqueous solutions at pH 6. We determined that the deposition potential not only affected the crystallinity of the deposited Cu2Sb, but also the ratio of antimony to copper. The temperature of the solution bath, as well as the smoothness of the growth substrate, were found to provide control over the crystallinity of the deposited Cu2Sb. The ability to electrodeposit crystalline Cu2Sb onto a variety of conducting surfaces is uncommon for intermetallics. The ability to deposit Cu2Sb onto transmission electron microscopy (TEM) grids has allowed the investigation of the morphology, composition, and crystallinity of Cu2Sb during the nucleation and growth of the material. This investigation demonstrated that multiple transformations occur during the early stage of the nucleation of Cu2Sb. A deeper understanding of this electrodeposition procedure for this compound will be useful for extending this technique to other crystalline intermetallics. Using the procedure developed for the single potential deposition of Cu2Sb films, the information from the TEM investigation and the results of a qualitative mathematical treatment, a pulse potential deposition procedure for depositing Cu2Sb nanowire arrays was developed. This procedure leads not only to the deposition of crystalline Cu2Sb nanowires, but also to uniform filling of the templates to afford wires of uniform composition and length. After the development of the procedures for the electrodeposition of Cu2Sb films and nanowire arrays from aqueous solutions at a single potential, the battery performance of the deposited Cu2Sb was examined. The ability to directly electrodeposit Cu2Sb onto the current collector has: (1) improved the characterization of the material during the lithiation and delithiation processes, (2) decreased the weight of inactive components, and (3) allowed for the deposition of high surface area Cu2Sb. The preliminary battery testing of electrodeposited Cu2Sb supported the absence of impurities in the deposited material and demonstrated that the electrodeposited Cu2Sb lithiated and delithiated similarly to Cu2Sb synthesized with different techniques. The deposition of Cu2Sb onto TEM grids was used for the first time without binder to characterize the morphology, composition and crystallinity changes that occur during the lithiation and delithiation of Cu2Sb. Superior capacity retention and rate performance was achieved with Cu2Sb electrodeposited onto high surface area copper foil. This superior performance demonstrates the improvement in battery performance that is expected from Cu2Sb nanowires, which have an order of magnitude higher surface area relative to the copper foam.

  4. Performance characteristics of an electric vehicle lead-acid battery pack at elevated temperatures

    NASA Technical Reports Server (NTRS)

    Chapman, P.

    1982-01-01

    Discharge testing data electric car battery pack over initial electrolyte temperature variations between 27 and 55 C are presented. The tests were conducted under laboratory conditions and then compared to detailed electric vehicle simulation models. Battery discharge capacity increased with temperature for constant current discharges, and battery energy capacity increased with temperature for constant power discharges. Dynamometer tests of the electric test vehicle showed an increase in range of 25% for the higher electrolyte temperature.

  5. Baseline Field Testing of BB-2590 Lithium-Ion Batteries using an iRobot FasTac 510 Robot

    DTIC Science & Technology

    2010-09-17

    No. 21320 Baseline Field Testing of BB-2590 Lithium - Ion Batteries using an iRobot FasTac 510 Robot U.S. Army Tank...SEP 2010 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Baseline Field Testing of BB-2590 Lithium - Ion Batteries using an iRobot...COVERED (From - To) Baseline Field Testing of BB-2590 Lithium - Ion Batteries using an 4. TITLE AND SUBTITLE iRobot FasTac 510 Robot 5a. CONTRACT

  6. Accelerated and real-time geosynchronous life cycling test performance of nickel-hydrogen batteries

    NASA Technical Reports Server (NTRS)

    Green, R. S.

    1985-01-01

    RCA Astro-Electronics currently has four nickel-hydrogen storage battery modules (11 cells each) on test in simulated geosynchronous life cycle regimes. These battery modules are of identical design to those used on the GSTAR (GTE Satellite Corp.) and Spacenet (GTE Spacenet Corp.) communications satellites. The batteries are being tested using an automated test station equipped with computer-controlled environmental chambers and recording equipment. The two battery types, 30 ampere-hours and 40 ampere-hours (GSTAR and Spacenet, respectively), are being electrically cycled using identical 44-day eclipse sequences at 5 C and vary with respect to depth of discharge, recharge ratio, duration of accumulated suntime, and the use of a reconditioning sequence. The test parameters are outlined and the preliminary test data and results are presented.

  7. Procedural techniques in sacral nerve modulation.

    PubMed

    Williams, Elizabeth R; Siegel, Steven W

    2010-12-01

    Sacral neuromodulation involves a staged process, including a screening trial and delayed formal implantation for those with substantial improvement. The advent of the tined lead has revolutionized the technology, allowing for a minimally invasive outpatient procedure to be performed under intravenous sedation. With the addition of fluoroscopy to the bilateral percutaneous nerve evaluation, there has been marked improvement in the placement of these temporary leads. Thus, the screening evaluation is now a better reflection of possible permanent improvement. Both methods of screening have advantages and disadvantages. Selection of a particular procedure should be tailored to individual patient characteristics. Subsequent implantation of the internal pulse generator (IPG) or explantation of an unsuccessful staged lead is straightforward outpatient procedure, providing minimal additional risk for the patient. Future refinement to the procedure may involve the introduction of a rechargeable battery, eliminating the need for IPG replacement at the end of the battery life.

  8. The Psychology Experiment Building Language (PEBL) and PEBL Test Battery.

    PubMed

    Mueller, Shane T; Piper, Brian J

    2014-01-30

    We briefly describe the Psychology Experiment Building Language (PEBL), an open source software system for designing and running psychological experiments. We describe the PEBL Test Battery, a set of approximately 70 behavioral tests which can be freely used, shared, and modified. Included is a comprehensive set of past research upon which tests in the battery are based. We report the results of benchmark tests that establish the timing precision of PEBL. We consider alternatives to the PEBL system and battery tests. We conclude with a discussion of the ethical factors involved in the open source testing movement. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. The Psychology Experiment Building Language (PEBL) and PEBL Test Battery

    PubMed Central

    Mueller, Shane T.; Piper, Brian J.

    2014-01-01

    Background We briefly describe the Psychology Experiment Building Language (PEBL), an open source software system for designing and running psychological experiments. New Method We describe the PEBL test battery, a set of approximately 70 behavioral tests which can be freely used, shared, and modified. Included is a comprehensive set of past research upon which tests in the battery are based. Results We report the results of benchmark tests that establish the timing precision of PEBL. Comparison with Existing Method We consider alternatives to the PEBL system and battery tests. Conclusions We conclude with a discussion of the ethical factors involved in the open source testing movement. PMID:24269254

  10. Low Temperature Life-cycle Testing of a Lithium-ion Battery for Low-earth-orbiting Spacecraft

    NASA Technical Reports Server (NTRS)

    Reid, Concha

    2004-01-01

    A flight-qualified, lithium-ion (Li-ion) battery developed for the Mars Surveyor Program 2001 lander is undergoing life-testing at low temperature under a low-Earth-orbit (LEO) profile to assess its capability to provide long term energy storage for aerospace missions. NASA has embarked upon an ambitious course to return humans to the moon by 2015-2020 in preparation for robotic and human exploration of Mars and robotic exploration of the moons of outer planets. Li-ion batteries are excellent candidates to provide power and energy storage for multiple aspects of these missions due to their low specific energy, low energy density, and excellent low temperature performance. Laboratory testing of Li-ion technology is necessary in order to assess lifetime, characterize multi-cell battery-level performance under aerospace conditions, and to gauge safety aspects of the technology. Life-cycle testing provides an opportunity to examine battery-level performance and the dynamics of individual cells in the stack over the entire life of the battery. Data generated through this testing will be critical to establish confidence in the technology for its widespread use in manned and unmanned mission. This paper discusses the performance of the 28 volt, 25 ampere-hour battery through 6000 LEO cycles, which corresponds to one year on LEO orbit. Testing is being performed at 0 C and 40% depth-of-discharge. Individual cell behaviors and their effect on the performance of the battery are described. Capacity, impedance, energy efficiency and end-of-discharge voltage at 1000 cycle intervals are reported. Results from this life-testing will help contribute to the database on battery-level performance of aerospace Li-ion batteries and low temperature cycling under LEO conditions.

  11. Safety modelling and testing of lithium-ion batteries in electrified vehicles

    NASA Astrophysics Data System (ADS)

    Deng, Jie; Bae, Chulheung; Marcicki, James; Masias, Alvaro; Miller, Theodore

    2018-04-01

    To optimize the safety of batteries, it is important to understand their behaviours when subjected to abuse conditions. Most early efforts in battery safety modelling focused on either one battery cell or a single field of interest such as mechanical or thermal failure. These efforts may not completely reflect the failure of batteries in automotive applications, where various physical processes can take place in a large number of cells simultaneously. In this Perspective, we review modelling and testing approaches for battery safety under abuse conditions. We then propose a general framework for large-scale multi-physics modelling and experimental work to address safety issues of automotive batteries in real-world applications. In particular, we consider modelling coupled mechanical, electrical, electrochemical and thermal behaviours of batteries, and explore strategies to extend simulations to the battery module and pack level. Moreover, we evaluate safety test approaches for an entire range of automotive hardware sets from cell to pack. We also discuss challenges in building this framework and directions for its future development.

  12. Advanced lead acid battery development project. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-02-01

    This project involved laboratory and road testing of the Horizon (registered) advanced lead acid batteries produced by Electrosource, Inc. A variety of electric vehicles in the fleet operated by the Sacramento Municipal Utility District and McClellan Air Force Base were used for road tests. The project was sponsored by the Defense Advanced Research Projects Agency under RA 93-23 entitled Electric Vehicle Technology and Infrastructure. The Horizon battery is a valve regulated, or sealed, lead acid battery produced in a variety of sizes and performance levels. During the project, several design and process improvements on the Horizon battery resulted in amore » production battery with a specific energy approaching 45 watt-hours per kilogram (Whr/kg) capable of delivering a peak current of 450 amps. The 12 volt, 95 amp-hour (Ahr) Horizon battery, model number 12N95, was placed into service in seven (7) test vehicles, including sedans, prototype lightweight electric vehicles, and passenger vans. Over 20,000 miles have been driven to date on vehicles powered by the Horizon battery. Road test results indicate that when the battery pack is used with a compatible charger and charge management system, noticeably improved acceleration characteristics are evident, and the vehicles provide a useful range almost 20% greater than with conventional lead-acid batteries.« less

  13. Thermographic inspection and quality assurance of energy conservation procedures for electric buses

    NASA Astrophysics Data System (ADS)

    Fennell, Henri C.

    1998-03-01

    Electric buses are one of the solutions for improving air quality in our cities. Many states are adopting 'no new diesel bus' policies, thus increasing the pressure to develop alternative vehicles. The fledgling electric vehicle technology suffers from acceptance problems by major transit authorities due primarily to limited travel range from each battery charge. Utilizing electric buses in the Northeast has the added problem of maintaining an adequate cabin temperature without the availability of heat from a diesel motor. Heating the passenger cabin with an electric heater which draws from the batteries' stored energy significantly reduces the already modest range of these vehicles; therefore, energy conservation measures play an important role in allowing electric vehicles to provide practical transit services. IR thermography, in conjunction with air leakage pressurization diagnostics, has proven to be an excellent tool for developing energy-efficient bus designs as well as a valuable in-service performance testing method. This paper is based on tests performed on several Advanced Vehicle Systems, Inc. electric buses during research performed under Northeast Alternative Vehicle Consortium and Defense Advanced Research Projects Agency grants. The work demonstrates the thermographic methods used and the real- world increased performance of retrofitted and newly designed buses resulting from this initial Portland Transit retrofit project and in a follow-up project to develop a cold weather specification for a new generation of electric buses. Early diagnostic and new-technology follow-up thermographic performance testing was paralleled by energy modeling of early baseline and re-designed vehicles. Modeling and performance data are included. As a result of this research, thermography, air-leakage/pressurization testing, and fog analysis techniques are now being used regularly in research and development and quality assurance procedures by electric bus manufacturers.

  14. Causal Analysis For Occurrence Report OR NA-SS-SNL-2000-2015-0005 Unexpected Type of Failure of Thermal Battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forbes, Elizabeth H.

    2015-08-01

    On 6/26/2015 at approximately 1445 in 894/136, a pulse thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following an electrical performance test that is routinely conducted on thermal batteries. A dedicated tester for this operation was used and it ran the test until the nominal 28-volt output of the battery had dropped to 5 volts, usually indicative of the battery being spent and safe enough to move. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another primary containment box within the same room;more » initial indications are that the battery experienced an over-pressurization failure which led to the battery's base plate being expelled and the operator receiving a non-recordable injury (bruising to the palm of the hand) from the pressure of the expulsion. The operator was wearing the prescribed PPE (safety glasses and high temperature glove) and was handling the battery appropriately with an open, flat hand. Pictures of the scene are below.« less

  15. Proposal of simple and novel method of capacity fading analysis using pseudo-reference electrode in lithium ion cells: Application to solvent-free lithium ion polymer batteries

    NASA Astrophysics Data System (ADS)

    Shono, Kumi; Kobayashi, Takeshi; Tabuchi, Masato; Ohno, Yasutaka; Miyashiro, Hajime; Kobayashi, Yo

    2014-02-01

    We propose a simple procedure for introducing a pseudo-reference electrode (PRE) to lithium ion batteries using isometric lithium metal placed between the cathode and anode, and we successfully obtained the cathode and anode voltage profiles, individual interfacial impedances, and the misalignment of the operation range between the cathode and anode after cycle operation. The proposed procedure is applicable to lithium ion battery systems using a solid electrolyte to prepare two cells with a lithium counter electrode. We determined the capacity decrease of a solvent-free lithium ion polymer battery consisting of a LiNi1/3Mn1/3Co1/3O2 (NMC), a polyether-based solid polymer electrolyte (SPE), and a graphite (Gr) with the proposed PRE over 1000 cycles. The capacity retention of the [Gr|SPE|NMC] cell reached 50% at the 1000th cycle upon the optimization of cell preparation, and we found that the main factor of the capacity decrease was the continuous irreversible loss of active lithium at the graphite anode, not the oxidation of the SPE. Our findings suggest that we should reconsider combining a polyether-based SPE with a conventionally used 4 V class cathode and a graphite anode to develop an innovative, safe, and low-cost battery for the expected large lithium ion battery systems for stationary use.

  16. Psychometric evaluation of a motor control test battery of the craniofacial region.

    PubMed

    von Piekartz, H; Stotz, E; Both, A; Bahn, G; Armijo-Olivo, S; Ballenberger, N

    2017-12-01

    The primary objective of this study was to determine the structural and known-group validity as well as the inter-rater reliability of a test battery to evaluate the motor control of the craniofacial region. Seventy volunteers without TMD and 25 subjects with TMD (Axes I) per the DC/TMD were asked to execute a test battery consisting of eight tests. The tests were video-taped in the same sequence in a standardised manner. Two experienced physical therapists participated in this study as blinded assessors. We used exploratory factor analysis to identify the underlying component structure of the eight tests. Internal consistency (Cronbach's α), inter-rater reliability (intra-class correlation coefficient) and construct validity (ie, hypothesis testing-known-group validity) (receiver operating curves) were also explored for the test battery. The structural validity showed the presence of one factor underlying the construct of the test battery. The internal consistency was excellent (0.90) as well as the inter-rater reliability. All values of reliability were close to 0.9 or above indicating very high inter-rater reliability. The area under the curve (AUC) was 0.93 for rater 1 and 0.94 for rater two, respectively, indicating excellent discrimination between subjects with TMD and healthy controls. The results of the present study support the psychometric properties of test battery to measure motor control of the craniofacial region when evaluated through videotaping. This test battery could be used to differentiate between healthy subjects and subjects with musculoskeletal impairments in the cervical and oro-facial regions. In addition, this test battery could be used to assess the effectiveness of management strategies in the craniofacial region. © 2017 John Wiley & Sons Ltd.

  17. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT XX, TROUBLESHOOTING ELECTRICAL SYSTEMS.

    ERIC Educational Resources Information Center

    Minnesota State Dept. of Education, St. Paul. Div. of Vocational and Technical Education.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO ACQUAINT THE TRAINEE WITH TROUBLESHOOTING PROCEDURES FOR DIESEL ENGINE ELECTRICAL SYSTEMS. TOPICS ARE (1) TROUBLESHOOTING ELECTRICAL SYSTEMS (INTRODUCTION), (2) TOOLS AND INSTRUMENTS FOR TROUBLESHOOTING, (3) THE BATTERY, (4) PERIODIC BATTERY SERVICING, (5) THE DC CHARGING SYSTEM, (6) PERIODIC…

  18. 78 FR 70532 - Notification of Proposed Production Activity, Hitachi Automotive Systems Americas, Inc., Subzone...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-26

    ... products (lithium-ion hybrid battery pack assemblies, electrical power steering modules, and electronic...-HK would be able to choose the duty rates during customs entry procedures that apply to lithium-ion..., alternators, distributors, other static converters, inverter modules, rotors/stators, batteries, ignition...

  19. A field operational test on valve-regulated lead-acid absorbent-glass-mat batteries in micro-hybrid electric vehicles. Part I. Results based on kernel density estimation

    NASA Astrophysics Data System (ADS)

    Schaeck, S.; Karspeck, T.; Ott, C.; Weckler, M.; Stoermer, A. O.

    2011-03-01

    In March 2007 the BMW Group has launched the micro-hybrid functions brake energy regeneration (BER) and automatic start and stop function (ASSF). Valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology are applied in vehicles with micro-hybrid power system (MHPS). In both part I and part II of this publication vehicles with MHPS and AGM batteries are subject to a field operational test (FOT). Test vehicles with conventional power system (CPS) and flooded batteries were used as a reference. In the FOT sample batteries were mounted several times and electrically tested in the laboratory intermediately. Vehicle- and battery-related diagnosis data were read out for each test run and were matched with laboratory data in a data base. The FOT data were analyzed by the use of two-dimensional, nonparametric kernel estimation for clear data presentation. The data show that capacity loss in the MHPS is comparable to the CPS. However, the influence of mileage performance, which cannot be separated, suggests that battery stress is enhanced in the MHPS although a battery refresh function is applied. Anyway, the FOT demonstrates the unsuitability of flooded batteries for the MHPS because of high early capacity loss due to acid stratification and because of vanishing cranking performance due to increasing internal resistance. Furthermore, the lack of dynamic charge acceptance for high energy regeneration efficiency is illustrated. Under the presented FOT conditions charge acceptance of lead-acid (LA) batteries decreases to less than one third for about half of the sample batteries compared to new battery condition. In part II of this publication FOT data are presented by multiple regression analysis (Schaeck et al., submitted for publication [1]).

  20. Laboratory discharge studies of a 6 V alkaline lantern-type battery Eveready Energizer no. 528, under various ambient temperatures (-15 deg C and + 22 deg C) and loads (30 omega and 60 omega)

    NASA Technical Reports Server (NTRS)

    Ahrens, S. T.

    1984-01-01

    The voltages of two Eveready No. 528 batteries, one the test battery, the other the control battery, were simultaneously recorded as they were discharged across 30 omega loads using a dual chart recorder. The test battery was initially put in a freezer at -15 + or - 3 C. After its voltage had fallen to .6 V, it was brought back out into the room at 22 + or - 3 C. A second run was made with 60 omega loads. Assuming a 3.0 V cut-off, the total energy output of the test battery at -15 C was 26 WHr 30 omega and 35 WHr 60 omega, and the corresponding numbers for the control battery at 22 C were 91 WHr and 100 WHr. When the test battery was subsequently allowed to warm up, the voltage rose above 4 V and the total energy output rose to 80 WHr 30 omega and 82 WHR 60 omega.

  1. Results of electric-vehicle propulsion system performance on three lead-acid battery systems

    NASA Technical Reports Server (NTRS)

    Ewashinka, J. G.

    1984-01-01

    Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

  2. Results of electric-vehicle propulsion system performance on three lead-acid battery systems

    NASA Technical Reports Server (NTRS)

    Ewashinka, J. G.

    1984-01-01

    Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries) were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

  3. Electric vehicle energy management system

    NASA Astrophysics Data System (ADS)

    Alaoui, Chakib

    This thesis investigates and analyzes novel strategies for the optimum energy management of electric vehicles (EVs). These are aimed to maximize the useful life of the EV batteries and make the EV more practical in order to increase its acceptability to market. The first strategy concerns the right choice of the batteries for the EV according to the user's driving habits, which may vary. Tests conducted at the University of Massachusetts Lowell battery lab show that the batteries perform differently from one manufacturer to the other. The second strategy was to investigate the fast chargeability of different batteries, which leads to reduce the time needed to recharge the EV battery pack. Tests were conducted again to prove that only few battery types could be fast charged. Test data were used to design a fast battery charger that could be installed in an EV charging station. The third strategy was the design, fabrication and application of an Electric Vehicle Diagnostic and Rejuvenation System (EVDRS). This system is based on Mosfet Controlled Thyristors (MCTs). It is capable of quickly identifying any failing battery(s) within the EV pack and rejuvenating the whole battery pack without dismantling them and unloading them. A novel algorithm to rejuvenate Electric Vehicle Sealed Lead Acid Batteries is described. This rejuvenation extends the useful life of the batteries and makes the EV more competitive. The fourth strategy was to design a thermal management system for EV, which is crucial to the safe operation, and the achievement of normal/optimal performance of, electric vehicle (EV) batteries. A novel approach for EV thermal management, based on Pettier-Effect heat pumps, was designed, fabricated and tested in EV. It shows the application of this type of technology for thermal management of EVs.

  4. 30 CFR 7.46 - Impact test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.46 Impact test. (a) Test... at 122 °F (50 °C) for a period of 48 hours. (2) Mount the covers on a battery box of the same design with which the covers are to be approved, including any support blocks, with the battery cells...

  5. Post-test analysis of lithium-ion battery materials at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Bareno, Javier; Dietz-Rago, Nancy; Bloom, Ira

    2014-03-01

    Electrochemical performance is often limited by surface and interfacial reactions at the electrodes. However, routine handling of samples can alter the very surfaces that are the object of study. Our approach combines standardized testing of batteries with sample harvesting under inert atmosphere conditions. Cells of different formats are disassembled inside an Argon glove box with controlled water and oxygen concentrations below 2 ppm. Cell components are characterized in situ, guaranteeing that observed changes in physicochemical state are due to electrochemical operation, rather than sample manipulation. We employ a complementary set of spectroscopic, microscopic, electrochemical and metallographic characterization to obtain a complete picture of cell degradation mechanisms. The resulting information about observed degradation mechanisms is provided to materials developers, both academic and industrial, to suggest new strategies and speed up the Research & Development cycle of Li-ion and related technologies. This talk will describe Argonne's post-test analysis laboratory, with an emphasis on capabilities and opportunities for collaboration. Cell disassembly, sample harvesting procedures and recent results will be discussed. This work was performed under the auspices of the U.S. Department of Energy, Office of Vehicle Technologies, Hybrid and Electric Systems, under Contract No. DE-AC02-06CH11357.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, W.; Shiota, T.

    Two categories of NaS traction batteries will be discussed: the present battery of Asea Brown Boveri and Powerplex and potential future NaS traction batteries. A large number of our present 24 kWh - 35 kw battery has been subjected to bench and on-vehicle performance tests. Test results will be presented. Future battery types to be volume produced in the early 1990`s are discussed with regard to energy, power and shape for special applications such a passenger car and van propulsion. Examples for those batteries will be given and projected performance characteristiques will be discussed.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, W.; Shiota, T.

    Two categories of NaS traction batteries will be discussed: the present battery of Asea Brown Boveri and Powerplex and potential future NaS traction batteries. A large number of our present 24 kWh - 35 kw battery has been subjected to bench and on-vehicle performance tests. Test results will be presented. Future battery types to be volume produced in the early 1990's are discussed with regard to energy, power and shape for special applications such a passenger car and van propulsion. Examples for those batteries will be given and projected performance characteristiques will be discussed.

  8. Accuracy statistics in predicting Independent Activities of Daily Living (IADL) capacity with comprehensive and brief neuropsychological test batteries.

    PubMed

    Karzmark, Peter; Deutsch, Gayle K

    2018-01-01

    This investigation was designed to determine the predictive accuracy of a comprehensive neuropsychological and brief neuropsychological test battery with regard to the capacity to perform instrumental activities of daily living (IADLs). Accuracy statistics that included measures of sensitivity, specificity, positive and negative predicted power and positive likelihood ratio were calculated for both types of batteries. The sample was drawn from a general neurological group of adults (n = 117) that included a number of older participants (age >55; n = 38). Standardized neuropsychological assessments were administered to all participants and were comprised of the Halstead Reitan Battery and portions of the Wechsler Adult Intelligence Scale-III. A comprehensive test battery yielded a moderate increase over base-rate in predictive accuracy that generalized to older individuals. There was only limited support for using a brief battery, for although sensitivity was high, specificity was low. We found that a comprehensive neuropsychological test battery provided good classification accuracy for predicting IADL capacity.

  9. The Construction and Analysis of a Test Battery Related to Volleyball Playing Capacity in Females.

    ERIC Educational Resources Information Center

    Disch, James G.; And Others

    The purpose of this report was to analyze a test battery constructed to describe and predict volleyball playing capacity in college and high school women. The following criteria were used for selecting a test for initial inclusion into the battery: (1) The test is related to a basic motor ability important to playing volleyball; (2) The test can…

  10. What Do Battery Testers Test?

    ERIC Educational Resources Information Center

    Chagnon, Paul

    1996-01-01

    Presents activities to determine whether it is better to test dry cells with an ammeter than with a voltmeter and how best to test alkaline batteries. Discusses classification of disposable testers as instruments. Concludes that a laboratory voltmeter gives a good indication of the condition of an alkaline cell while carbon batteries are best…

  11. Performance and safety testing of lithium batteries for the Expendable, Mobile, ASW Training Target (EMATT)

    NASA Astrophysics Data System (ADS)

    Hallal, P. B.; Bis, R. F.

    1986-08-01

    The developmental EMATT (expendable, mobile, ASW training target) may use a high-energy (lithium/sulfuryl chloride) battery system. Safety problems with the original battery cell design were experienced during early performance and safety testing. After redesign of the battery cell, performance and safety tests were made under specified abuse conditions, as well as under simulated launch conditions. The test results showed that the power system now meets all safety requirements, and that the EMATT vehicle is safe to deploy for its engineering development phase.

  12. Human-rated Safety Certification of a High Voltage Robonaut Lithium-ion Battery

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith; Yayathi, S.; Johnson, M.; Waligora, T.; Verdeyen, W.

    2013-01-01

    NASA's rigorous certification process is being followed for the R2 high voltage battery program for use of R2 on International Space Station (ISS). Rigorous development testing at appropriate levels to credible off-nominal conditions and review of test data led to design improvements for safety at the virtual cell, cartridge and battery levels. Tests were carried out at all levels to confirm that both hardware and software controls work. Stringent flight acceptance testing of the flight battery will be completed before launch for mission use on ISS.

  13. A differential approach to microcomputer test battery development and implementation

    NASA Technical Reports Server (NTRS)

    Kennedy, R. S.; Baltzley, D. R.; Osteen, M. K.; Turnage, J. J.

    1988-01-01

    The present microcomputer-based performance test battery emphasizes psychometric theory and utility for repeated-measures applications during extended exposure to various environmental stressors. In the menu that has been defined at the current state of this system's development, there are more than 30 'qualified' mental tests which stabilize in less than 10 min and possess test-retest reliabilities greater than 0.7 for a three-minute test/work period. The battery encompasses tests of cognition, information processing, psychomotor skill, memory, mood, etc. Several of the tests have demonstrated sensitivity to chemoradiotherapy, sleep loss, hypoxia, amphetamines, thermal stress, sensory deprivation, altitude, fatigue, and alcohol use. Recommendations are presented for 6-, 12-, and 22-min batteries.

  14. NREL Scientists and Engineers Recognized for Top Innovations | NREL | News

    Science.gov Websites

    commercially available, large-format isothermal battery calorimeter for lithium-ion battery safety testing to test the performance and safety of large-format lithium-ion batteries used extensively in electric develop NREL intellectual property representing an isothermal battery calorimeter. The technical

  15. Development and Testing of an UltraBattery-Equipped Honda Civic Hybrid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sally; Tyler Gray; Pattie Hovorka

    2012-08-01

    The UltraBattery Retrofit Project DP1.8 and Carbon Enriched Project C3, performed by ECOtality North America (ECOtality) and funded by the U.S. Department of Energy and the Advanced Lead Acid Battery Consortium (ALABC), are established to demonstrate the suitability of advanced lead battery technology in hybrid electrical vehicles (HEVs). A profile, termed the “Simulated Honda Civic HEV Profile” (SHCHEVP) has been developed in Project DP1.8 in order to provide reproducible laboratory evaluations of different battery types under real-world HEV conditions. The cycle is based on the Urban Dynamometer Driving Schedule and Highway Fuel Economy Test cycles and simulates operation of amore » battery pack in a Honda Civic HEV. One pass through the SHCHEVP takes 2,140 seconds and simulates 17.7 miles of driving. A complete nickel metal hydride (NiMH) battery pack was removed from a Honda Civic HEV and operated under SHCHEVP to validate the profile. The voltage behavior and energy balance of the battery during this operation was virtually the same as that displayed by the battery when in the Honda Civic operating on the dynamometer under the Urban Dynamometer Driving Schedule and Highway Fuel Economy Test cycles, thus confirming the efficacy of the simulated profile. An important objective of the project has been to benchmark the performance of the UltraBatteries manufactured by both Furukawa Battery Co., Ltd., Japan (Furakawa) and East Penn Manufacturing Co., Inc. (East Penn). Accordingly, UltraBattery packs from both Furakawa and East Penn have been characterized under a range of conditions. Resistance measurements and capacity tests at various rates show that both battery types are very similar in performance. Both technologies, as well as a standard lead-acid module (included for baseline data), were evaluated under a simple HEV screening test. Both Furakawa and East Penn UltraBattery packs operated for over 32,000 HEV cycles, with minimal loss in performance; whereas the standard lead-acid unit experienced significant degradation after only 6,273 cycles. The high-carbon, ALABC battery manufactured in Project C3 also was tested under the advanced HEV schedule. Its performance was significantly better than the standard lead-acid unit, but was still inferior compared with the UltraBattery. The batteries supplied by Exide as part of the C3 Project performed well under the HEV screening test, especially at high temperatures. The results suggest that higher operating temperatures may improve the performance of lead-acid-based technologies operated under HEV conditions—it is recommended that life studies be conducted on these technologies under such conditions.« less

  16. High rate lithium/thionyl chloride bipolar battery development

    NASA Technical Reports Server (NTRS)

    Russell, Philip G.; Goebel, F.

    1994-01-01

    Presented in viewgraph format are results and accomplishments on the development of lithium/thionyl chloride bipolar batteries. Results include the development of manufacturing capability for producing large quantities of uniform cathodes and bipolar plates; the development of assembly, sealing, and activation procedures for fabrication of battery modules containing up to 150 cells in bipolar configuration; and the successful demonstration of a 10.7 kW 150-cell module with constant power pulse discharge, 20 second pulse, and 10 percent duty cycle.

  17. Validity of a semantically cued recall procedure for the mini-mental state examination.

    PubMed

    Yuspeh, R L; Vanderploeg, R D; Kershaw, D A

    1998-10-01

    The validity of supplementing the three-item recall portion of the Mini-Mental State Examination (MMSE) with a cued recall procedure to help specify the nature of patients' memory problems was examined. Subjects were 247 individuals representing three diagnostic groups: Alzheimer's disease (AD), subcortical vascular ischemic dementia (SVaD), and normal controls. Individuals were administered a battery of neuropsychological tests, including the MMSE, as part of a comprehensive evaluation for the presence of dementia or other neurologic disorder. MMSE performance differed among groups. The three-item free recall performance also differed among groups, with post hoc analyses revealing the AD and SVaD groups were more impaired than controls but did not differ significantly from each other. Following a cued recall procedure of the MMSE three-items, groups differed, with post hoc analyses showing that AD patients failed to benefit from cues, whereas SVaD patients performed significantly better and comparable to control subjects. Significant correlations between the MMSE three-item cued recall performance and other memory measures demonstrated concurrent validity. Consistent with previous research indicating that SVaD is associated with memory encoding and retrieval deficits, whereas AD is associated with consolidation and storage problems, the present study supported the validity of the cued recall procedure of the three items on the MMSE in helping to distinguish between patients with AD and those with a vascular dementia with primarily subcortical pathology; however, despite these findings, a more extensive battery of neuropsychological measures is still recommended to consistently assess subtle diagnostic differences in these memory processes.

  18. Nickel-Hydrogen and Lithium Ion Space Batteries

    NASA Technical Reports Server (NTRS)

    Reid, Robert O., II

    2004-01-01

    The tasks of the Electrochemistry Branch of NASA Glenn Research Center are to improve and develop high energy density and rechargeable, life-long batteries. It is with these batteries that people across the globe are able to power their cell phones, laptop computers, and cameras. Here, at NASA Glenn Research Center, the engineers and scientists of the Electrochemistry branch are leading the way in the development of more powerful, long life batteries that can be used to power space shuttles and satellites. As of now, the cutting edge research and development is being done on nickel-hydrogen batteries and lithium ion batteries. Presently, nickel-hydrogen batteries are common types of batteries that are used to power satellites, space stations, and space shuttles, while lithium batteries are mainly used to power smaller appliances such as portable computers and phones. However, the Electrochemistry Branch at NASA Glenn Research Center is focusing more on the development of lithium ion batteries for deep space use. Because of the limitless possibilities, lithium ion batteries can revolutionize the space industry for the better. When compared to nickel-hydrogen batteries, lithium ion batteries possess more advantages than its counterpart. Lithium ion batteries are much smaller than nickel-hydrogen batteries and also put out more power. They are more energy efficient and operate with much more power at a reduced weight than its counterpart. Lithium ion cells are also cheaper to make, possess flexibility that allow for different design modifications. With those statistics in hand, the Electrochemistry Branch of NASA Glenn has decided to shut down its Nickel-Hydrogen testing for lithium ion battery development. Also, the blackout in the summer of 2003 eliminated vital test data, which played a part in shutting down the program. from the nickel-hydrogen batteries and compare it to past data. My other responsibilities include superheating the electrolyte that is used in the nickel-hydrogen cell in a calorimeter to test its performance under various conditions. 1 used a program called Arbin to study my data. The Arbin allows me to look at different parameters such as pressure and time and how they affect the changing temperature of the electrolyte that is being tested. In addition, I had the responsibility of taking apart and modifying battery coolers that would be used. My mentors told me that the batteries kept shutting down, so it was my responsibility to remove excess fan grilles, rotate the fans, and then switch the aluminum standoffs with nylon ones so that the coolers could operate without problems. My last task is to collect all the battery test data and organize them into charts using Microsoft Excel, before the Branch is able to conduct its research on lithium ion batteries. Therefore, during my tenure, it is my responsibility to take down final test data

  19. Hypervelocity Impact Testing of Nickel Hydrogen Battery Cells

    NASA Technical Reports Server (NTRS)

    Frate, David T.; Nahra, Henry K.

    1996-01-01

    Nickel-Hydrogen (Ni/H2) battery cells have been used on several satellites and are planned for use on the International Space Station. In January 1992, the NASA Lewis Research Center (LeRC) conducted hypervelocity impact testing on Ni/H2 cells to characterize their failure modes. The cell's outer construction was a 24 mil-thick Inconel 718 pressure vessel. A sheet of 1.27 cm thick honeycomb was placed in front of the battery cells during testing to simulate the on-orbit box enclosure. Testing was conducted at the NASA White Sands Test Facility (WSTF). The hypervelocity gun used was a 7.6 mm (0.30 caliber) two-stage light gas gun. Test were performed at speeds of 3, 6, and 7 km/sec using aluminum 2017 spherical particles of either 4.8 or 6.4 mm diameter as the projectile. The battery cells were electrically charged to about 75 percent of capacity, then back-filled with hydrogen gas to 900 psi simulating the full charge condition. High speed film at 10,000 frames/sec was taken of the impacts. Impacts in the dome area (top) and the electrode area (middle) of the battery cells were investigated. Five tests on battery cells were performed. The results revealed that in all of the test conditions investigated, the battery cells simply vented their hydrogen gas and some electrolyte, but did not burst or generate any large debris fragments.

  20. Primary zinc-air batteries for space power

    NASA Technical Reports Server (NTRS)

    Bragg, Bobby J.; Bourland, Deborah S.; Merry, Glenn; Putt, Ron

    1992-01-01

    Prismatic HR and LC cells and batteries were built and tested, and they performed well with respect to the program goals of high capacity and high rate capability at specific energies. The HR batteries suffered reduced utilizations owing to dryout at the 2 and 3 A rates for the 50 C tests owing to the requirement for forced convection. The LC batteries suffered reduced utilizations under all conditions owing to the chimney effect at 1 G, although this effect would not occur at 0 G. An empirical model was developed which accurately predicted utilizations and average voltages for single cells, although thermal effects encountered during battery testing caused significant deviations, both positive and negative, from the model. Based on the encouraging results of the test program, we believe that the zinc-air primary battery of a flat, stackable configuration can serve as a high performance and safe power source for a range of space applications.

  1. Development of a lead-acid battery for a hybrid electric vehicle

    NASA Astrophysics Data System (ADS)

    Cooper, A.

    In September 2000, a project reliable, highly optimized lead-acid battery (RHOLAB) started under the UK Foresight Vehicle Programme with the objective of developing an optimized lead-acid battery solution for hybrid electric vehicles. The work is based on a novel, individual, spirally-wound valve-regulated lead-acid 2 V cell optimized for HEV use and low variability. This cell is being used as a building block for the development of a complete battery pack that is managed at the cell level. Following bench testing, this battery pack is to be thoroughly evaluated by substituting it for the Ni-MH pack in a Honda Insight. The RHOLAB cell is based on the 8 Ah Hawker Cyclon cell which has been modified to have current take-off at both ends—the dual-tab design. In addition, a variant has been produced with modified cell chemistry to help deal with problems that can occur when these valve-regulated lead-acid battery (VRLA) cells operate in a partial-state-of-charge condition. The cells have been cycled to a specially formulated test cycle based on real vehicle data derived from testing the Honda Insight on the various test tracks at the Millbrook Proving Grounds in the UK. These cycling tests have shown that the lead-acid pack can be successfully cycled when subjected to the high current demands from the vehicle, which have been measured at up to 15 C on discharge and 8 C during regenerative recharging, and cycle life is looking very promising under this arduous test regime. Concurrent with this work, battery development has been taking place. It was decided early on to develop the 144 V battery as four 36 V modules. Data collection and control has been built-in and special steps taken to minimize the problems of interconnect in this complex system. Development of the battery modules is now at an advanced stage. The project plan then allows for extensive testing of the vehicle with its lead-acid battery at Millbrook so it can be compared with the benchmark tests which have already been carried out on the vehicle with its Ni-MH batteries.

  2. Influence of Na+, K+, Mn2+, Fe2+ and Zn2+ ions on the electrodeposition of Ni-Co alloys: Implications for the recycling of Ni-MH batteries

    NASA Astrophysics Data System (ADS)

    Blanco, S.; Orta-Rodriguez, R.; Delvasto, P.

    2017-01-01

    A hydrometallurgical recycling procedure for the recovery of a mixed rare earths sulfate and an electrodeposited Ni-Co alloy has been described. The latter step was found to be complex, due to the presence of several ions in the battery electrode materials. Electrochemical evaluation of the influence of the ions on the Ni-Co alloy deposition was carried out by cyclic voltammetry test. It was found that ions such as K+, Fe2+ and Mn2+ improved the current efficiency for the Ni-Co deposition process on a copper surface. On the other hand, Na+ and Zn2+ ions exhibited a deleterious behaviour, minimizing the values of the reduction current. The results were used to suggest the inclusion of additional steps in the process flow diagram of the recycling operation, in order to eliminate deleterious ions from the electroplating solution.

  3. Template-Free Synthesis of Hollow-Structured Co 3 O 4 Nanoparticles as High-Performance Anodes for Lithium-Ion Batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Deli; Yu, Yingchao; He, Huan

    2015-02-24

    We have developed a template-free procedure to synthesize Co3O4 hollow-structured nanoparticles on a Vulcan XC-72 carbon support. The material was synthesized via an impregnation–reduction method followed by air oxidation. In contrast to spherical particles, the hollow-structured Co3O4 nanoparticles exhibited excellent lithium storage capacity, rate capability, and cycling stability when used as the anode material in lithium-ion batteries. Electrochemical testing showed that the hollow-structured Co3O4 particles delivered a stable reversible capacity of about 880 mAh/g (near the theoretical capacity of 890 mAh/g) at a current density of 50 mA/g after 50 cycles. The superior electrochemical performance is attributed to its uniquemore » hollow structure, which combines nano- and microscale properties that facilitate electron transfer and enhance structural robustness.« less

  4. Prototype Software for Future Spaceflight Tested at Mars Desert Research Station

    NASA Technical Reports Server (NTRS)

    Clancey, William J.; Sierhuis, Maaretn; Alena, Rick; Dowding, John; Garry, Brent; Scott, Mike; Tompkins, Paul; vanHoof, Ron; Verma, Vandi

    2006-01-01

    NASA scientists in MDRS Crew 49 (April 23-May 7, 2006) field tested and significantly extended a prototype monitoring and advising system that integrates power system telemetry with a voice commanding interface. A distributed, wireless network of functionally specialized agents interacted with the crew to provide alerts (e.g., impending shut-down of inverter due to low battery voltage), access md interpret historical data, and display troubleshooting procedures. In practical application during two weeks, the system generated speech over loudspeakers and headsets lo alert the crew about the need to investigate power system problems. The prototype system adapts the Brahms/Mobile Agents toolkit to receive data from the OneMeter (Brand Electronics) electric metering system deployed by Crew 47. A computer on the upper deck was connected to loudspeakers, four others were paired with wireless (Bluetooth) headsets that enabled crew members to interact with their personal agents from anywhere in the hab. Voice commands and inquiries included: 1. What is the {battery | generator} {volts | amps | volts and amps}? 2. What is the status of the {generator | inverter | battery | solar panel}? 3. What is the hab{itat} {power usage | volts | voltage | amps | volts and amps}? 4. What was the average hab{itat} {amps | volts | voltage} since <#> {AM | PM)? 5. When did the {generator | batteries} change status? 6. Tell {me I | everyone} when{ ever} the generator goes offline. 7. Tell {me | | everyone} when the hab{itat} {amps | volts | voltage} {exceeds | drops brelow} <#>. 8. {Send | Take | Record} {a} voice note {(for | to} } {at

  5. Development and Implementation of a Hardware In-the-Loop Test Bed for Unmanned Aerial Vehicle Control Algorithms

    NASA Technical Reports Server (NTRS)

    Nyangweso, Emmanuel; Bole, Brian

    2014-01-01

    Successful prediction and management of battery life using prognostic algorithms through ground and flight tests is important for performance evaluation of electrical systems. This paper details the design of test beds suitable for replicating loading profiles that would be encountered in deployed electrical systems. The test bed data will be used to develop and validate prognostic algorithms for predicting battery discharge time and battery failure time. Online battery prognostic algorithms will enable health management strategies. The platform used for algorithm demonstration is the EDGE 540T electric unmanned aerial vehicle (UAV). The fully designed test beds developed and detailed in this paper can be used to conduct battery life tests by controlling current and recording voltage and temperature to develop a model that makes a prediction of end-of-charge and end-of-life of the system based on rapid state of health (SOH) assessment.

  6. Performance Testing of Yardney Li-Ion Cells and Batteries in Support of Future NASA Missions

    NASA Technical Reports Server (NTRS)

    Smart, M. C.; Ratnakumar, B. V.; Whitcanack, L. D.; Puglia, F. J.; Santee, S.; Gitzendanner, R.

    2009-01-01

    NASA requires lightweight rechargeable batteries for future missions to Mars and the outer planets that are capable of operating over a wide range of temperatures, with high specific energy and energy densities. Due to the attractive performance characteristics, Li-ion batteries have been identified as the battery chemistry of choice for a number of future applications. For example, JPL is planning to launch another unmanned rover mission to the planet Mars. This mission, referred to as the Mars Science Laboratory (MSL), will involve the use of a rover that is much larger than the previously developed Spirit and Opportunity Rovers for the 2003 Mars Exploration Rover (MER) mission, that are currently still in operation on the surface of the planet after more than five years. Part of the reason that the MER rovers have operated so successfully, far exceeding the required mission duration of 90 sols, is that they possess robust Li-ion batteries, manufactured by Yardney Technical Products, which have demonstrated excellent life characteristics. Given the excellent performance characteristics displayed, similar Li-ion batteries have been projected to successfully meet the mission requirements of the up-coming MSL mission. In addition to future missions to Mars, Li-ion technology is attractive for a number of other future NASA applications which require high specific energy, rechargeable batteries. To ascertain the viability of using Li-ion batteries for these applications, a number of performance validation tests have been performed on both Yardney cells and batteries of various sizes. These tests include mission simulation tests, charge and discharge rate characterization testing, cycle life testing under various conditions, and storage testing.

  7. The Behavior Assessment Battery: a preliminary study of non-stuttering Pakistani grade-school children.

    PubMed

    Vanryckeghem, Martine; Mukati, Samad A

    2006-01-01

    In recent years, the importance of a multimodal approach to the assessment of the person who stutters (PWS) has become increasingly recognized. The Behavior Assessment Battery (BAB), which is a normed test procedure developed by G. Brutten, makes it possible to assess the multidimensional facets of this disorder. The emotional and speech-disruptive components that differentiate one who stutters from one who does not (PWNS) are evaluated by means of the Speech Situation Checklist (SSC), their use of behaviours secondary to stuttering are assessed through the Behavior Checklist (BCL) and the person's speech-related attitude is determined via the Communication Attitude Test (CAT). Each of these BAB tests has been shown to be a reliable and valid measure whose obtained normative data are essentially equivalent in Western countries. Because of the lack of normative data on children from non-Western cultures, the present preliminary study was aimed to investigate if the affective, behavioural and cognitive reports of non-stuttering Pakistani children on the BAB measures are like those of their Western peers. Forty-five non-stuttering Pakistani children between the ages of 8 and 11 were administered the SSC, BCL and CAT. As in previous studies, the mean score of the normally fluent children on each of the BAB tests fell into the lower end of the possible distribution of scores. Intercorrelations between the different tests were statistically significant. Although the BCL and CAT results were similar to those found in Western-based investigations, the emotional reaction and speech disruption scores on the SSC reported by Pakistani children sampled were numerically higher to an extent that is noteworthy. The latter finding suggests that this particular BAB measure might be affected by cultural differences. It points to the possibility that the norms of test procedures, such as the BAB, might not be fully appropriate for use in other than Western cultures.

  8. Laboratory testing of GNB switch 12 volt SLI (starting, lighting and ignition) battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, J.E.

    1990-03-01

    The purpose of this report is to describe the testing performed on the GNB Switch flooded lead SLI battery in the INEL Electric Vehicle Battery Laboratory, to present the results and conclusions of this testing, and to make appropriate recommendations. GNB Inc. is a Pacific Dunlop Company. The term SWITCH'' comes from the fact that this product consists of two batteries in one package which can be connected in parallel by a switch for higher cranking energy or reserve capacity. The smaller second battery is float charged through a diode. GNB advertising describes the SWITCH'' as The Battery With Amore » Spare''. The Switch, a BCI Group 24 SLI (Starting, Lighting and Ignition) battery, is manufactured in Georgia for sale throughout the US. The initial design work on the Switch was done in Australia under the Pulsar name by Dunlop. 11 figs., 3 tabs.« less

  9. Evaluation of a new charge algorithm for a lead-acid battery with gelled electrolyte using a 96V gel cell IV as a test battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nowak, D.K.

    1989-10-01

    This document has reported a summary of test results obtained utilizing the new UAH charge algorithm for Lead-Acid batteries with gelled electrolyte. The battery performance data for a 96V Phase IV Gel/Cell battery pack was tested in a Jet Industries Electrica vehicle. It was shown that the new charge concept is sound although there can be problems with batteries that are highly imbalanced and where excessive electronic noise is experienced on the electronic signal feed-back line that carries the voltage sensor signals from the battery. Additional work is needed to add intelligence to the charge algorithm in terms of amore » better ability to extract the beginning of gas development from the voltage spread function. This can probably be accomplished by scanning the voltages more often and including that data into the function analysis by adding software filters. The Phase IV Gel/Cell battery performance was found to be about 20% lower than that of the Phase III Gel/Cell battery. Problems with cell valve leakage were encountered in the Phase IV Gel/Cell that pose a threat to battery life although so far no battery module has been lost. 2 refs., 13 figs., 4 tabs.« less

  10. Commercial aerospace and terrestrial applications of nickel-hydrogen batteries

    NASA Astrophysics Data System (ADS)

    Caldwell, Dwight B.; Coates, Dwaine K.; Fox, Chris L.; Miller, Lee E.

    1996-03-01

    The nickel-hydrogen battery system, used extensively in the aerospace industry to supply electrical power to earth-orbital satellites for communications, observation, and military applications, is being developed for commercial, terrestrial applications. Low-cost components, electrodes, cell designs, and battery designs are currently being tested. Catalytic hydrogen electrodes have been developed which are compatible with commercial nickel battery cost. Prismatic and spiral-wound cell designs have been built and tested. Common pressure vessel and dependent pressure vessel battery designs are also being evaluated. The nickel-hydrogen battery offers potential cycle life unequaled by any other battery system. This makes the battery ideal for many commercial and terrestrial energy storage applications such as telecommunication, remote stand-alone power systems, utility load-leveling, and other applications which require long life and a truly maintenance-free and abuse-tolerant battery system.

  11. Battery cycling and calendar aging: year one testing results.

    DOT National Transportation Integrated Search

    2016-07-01

    This report is meant to provide an update on the ongoing battery testing performed by the Hawaii Natural Energy Institute to evaluate Electric Vehicle (EV) battery durability and reliability under electric utility grid operations. Commercial EV batte...

  12. Lead-acid batteries in micro-hybrid applications. Part II. Test proposal

    NASA Astrophysics Data System (ADS)

    Schaeck, S.; Stoermer, A. O.; Albers, J.; Weirather-Koestner, D.; Kabza, H.

    In the first part of this work [1] selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. [1,6]. The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already.

  13. The 1975 GSFC Battery Workshop

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The proceedings of the 1975 Goddard Space Flight Center Battery Workshop are presented. The major topics of discussion were nickel cadmium batteries and, to a lesser extent, nickel hydrogen batteries. Battery design, manufacturing techniques, testing programs, and electrochemical characteristics were considered. The utilization of these batteries for spacecraft power supplies was given particular attention.

  14. Nickelzinc Batteries for RPV Applications.

    DTIC Science & Technology

    1981-06-01

    batteries used in the BQM-34A target drones are: 1) The secondary nickel-zinc system is able to provide superior Amp-Hr capacity with respect to volume as...7) MAR-5013 Flight Test batteries, have been constructed and shipped to Tyndall AFB for testing in the BQM- 34A remotely piloted target drone . The...ditioning.The seventh battery was lost on a flight mission when the target drone was shot down. Refer to Table 16 for a summary of battery history prior

  15. Field testing the Wildlink Capture Collar on wolves

    USGS Publications Warehouse

    Mech, L. David; Gesit, Eric L.

    1992-01-01

    Seventeen Wildlink capture collars were tested 61 times on 18 gray wolves (Canis lupus) during 1989-1991 in the Superior National Forest of northeastern Minnesota. Overall success rate was 89%, and most failures were attributable to premature battery expiration. When batteries were changed ≤ every 2 months, 17 of 17 tests succeeded. With an upgraded version of the collar in which batteries lasted longer, 17 of 18 tests succeeded. Over the 2-year study, 6 of the 17 collars were lost. For serially recapturing individuals, the Wildlink collar proved useful and reliable if care was taken to replace batteries at proper intervals.

  16. Parametric tests of a 40-Ah bipolar nickel-hydrogen battery

    NASA Technical Reports Server (NTRS)

    Cataldo, R. L.

    1986-01-01

    A series of tests were performed to characterize battery performance relating to certain operating parameters which include charge current, discharge current, temperature, and pressure. The parameters were varied to confirm battery design concepts and to determine optimal operating conditions.

  17. Sizing procedures for sun-tracking PV system with batteries

    NASA Astrophysics Data System (ADS)

    Nezih Gerek, Ömer; Başaran Filik, Ümmühan; Filik, Tansu

    2017-11-01

    Deciding optimum number of PV panels, wind turbines and batteries (i.e. a complete renewable energy system) for minimum cost and complete energy balance is a challenging and interesting problem. In the literature, some rough data models or limited recorded data together with low resolution hourly averaged meteorological values are used to test the sizing strategies. In this study, active sun tracking and fixed PV solar power generation values of ready-to-serve commercial products are recorded throughout 2015-2016. Simultaneously several outdoor parameters (solar radiation, temperature, humidity, wind speed/direction, pressure) are recorded with high resolution. The hourly energy consumption values of a standard 4-person household, which is constructed in our campus in Eskisehir, Turkey, are also recorded for the same period. During sizing, novel parametric random process models for wind speed, temperature, solar radiation, energy demand and electricity generation curves are achieved and it is observed that these models provide sizing results with lower LLP through Monte Carlo experiments that consider average and minimum performance cases. Furthermore, another novel cost optimization strategy is adopted to show that solar tracking PV panels provide lower costs by enabling reduced number of installed batteries. Results are verified over real recorded data.

  18. The 1984 Goddard Space Flight Center Battery Workshop

    NASA Technical Reports Server (NTRS)

    Morrow, G. W. (Editor)

    1985-01-01

    Various topics related to spacecraft power supply systems are discussed. Regenerative fuel cells, lithium molybdenum batteries, nickel hydrogen batteries, nickel cadmium batteries, failure analysis, and performance testing are covered.

  19. Energy Storage Requirements & Challenges for Ground Vehicles

    DTIC Science & Technology

    2010-03-18

    Titinate Evaluation Cell Evaluation Battery Aging Phenomenon Battery SOC/SOH Determination Modeling ARM 100 LiIon APU Lion Cell Evaluation Cell...Advanced Batteries Fuels Th er m al Ma na ge m en t Radiators Heat Recovery Thermal Interface Materials Phase Change Cooling Advanced Electronics...in all energy storage Energy Storage Team Mission Battery Technology Evaluation Lab Module Test & Eval Cell Test & Eval 6UNCLASSIFIED Pacing Vehicle

  20. Validation of a Paper and Pencil Test Battery for the Diagnosis of Minimal Hepatic Encephalopathy in Korea.

    PubMed

    Jeong, Jae Yoon; Jun, Dae Won; Bai, Daiseg; Kim, Ji Yean; Sohn, Joo Hyun; Ahn, Sang Bong; Kim, Sang Gyune; Kim, Tae Yeob; Kim, Hyoung Su; Jeong, Soung Won; Cho, Yong Kyun; Song, Do Seon; Kim, Hee Yeon; Jung, Young Kul; Yoon, Eileen L

    2017-09-01

    The aim of this study was to validate a new paper and pencil test battery to diagnose minimal hepatic encephalopathy (MHE) in Korea. A new paper and pencil test battery was composed of number connection test-A (NCT-A), number connection test-B (NCT-B), digit span test (DST), and symbol digit modality test (SDMT). The norm of the new test was based on 315 healthy individuals between the ages of 20 and 70 years old. Another 63 healthy subjects (n = 31) and cirrhosis patients (n = 32) were included as a validation cohort. All participants completed the new paper and pencil test, a critical flicker frequency (CFF) test and computerized cognitive function test (visual continuous performance test [CPT]). The scores on the NCT-A and NCT-B increased but those of DST and SDMT decreased according to age. Twelve of the cirrhotic patients (37.5%) were diagnosed with MHE based on the new paper and pencil test battery. The total score of the paper and pencil test battery showed good positive correlation with the CFF (r = 0.551, P < 0.001) and computerized cognitive function test. Also, this score was lower in patients with MHE compared to those without MHE (P < 0.001). Scores on the CFF (32.0 vs. 28.7 Hz, P = 0.028) and the computer base cognitive test decreased significantly in patients with MHE compared to those without MHE. Test-retest reliability was comparable. In conclusion, the new paper and pencil test battery including NCT-A, NCT-B, DST, and SDMT showed good correlation with neuropsychological tests. This new paper and pencil test battery could help to discriminate patients with impaired cognitive function in cirrhosis (registered at Clinical Research Information Service [CRIS], https://cris.nih.go.kr/cris, KCT0000955). © 2017 The Korean Academy of Medical Sciences.

  1. Nickel cadmium battery operations and performance

    NASA Technical Reports Server (NTRS)

    Rao, Gopalakrishna; Prettyman-Lukoschek, Jill; Calvin, Richard; Berry, Thomas; Bote, Robert; Toft, Mark

    1994-01-01

    The Earth Radiation Budget Satellite (ERBS), Compton Gamma Ray Observatory (CGRO), Upper Atmosphere Research Satellite (UARS), and Extreme Ultraviolet Explorer (EUVE) spacecraft are operated from NASA's Goddard Space Flight Center (GSFC) in Greenbelt, Maryland. On-board power subsystems for each satellite employ NASA Standard 50 Ampere-hour (Ah) nickel-cadmium batteries in a parallel configuration. To date, these batteries have exhibited degradation over periods from several months (anomalous behavior, UARS and CGRO (MPS-1); to little if any, EUVE) to several years (old age, normal behavior, ERBS). Since the onset of degraded performance, each mission's Flight Operations Team (FOT), under the direction of their cognizant GSFC Project Personnel and Space Power Application Branch's Engineers has closely monitored the battery performance and implemented several charge control schemes in an effort to extend battery life. Various software and hardware solutions have been developed to minimize battery overcharge. Each of the four sections of this paper covers a brief overview of each mission's operational battery management and its associated spacecraft battery performance. Also included are new operational procedures developed on-orbit that may be of special interest to future mission definition and development.

  2. Porous Carbon Paper as Interlayer to Stabilize the Lithium Anode for Lithium-Sulfur Battery.

    PubMed

    Kong, Ling-Long; Zhang, Ze; Zhang, Ye-Zheng; Liu, Sheng; Li, Guo-Ran; Gao, Xue-Ping

    2016-11-23

    The lithium-sulfur (Li-S) battery is expected to be the high-energy battery system for the next generation. Nevertheless, the degradation of lithium anode in Li-S battery is the crucial obstacle for practical application. In this work, a porous carbon paper obtained from corn stalks via simple treating procedures is used as interlayer to stabilize the surface morphology of Li anode in the environment of Li-S battery. A smooth surface morphology of Li is obtained during cycling by introducing the porous carbon paper into Li-S battery. Meanwhile, the electrochemical performance of sulfur cathode is partially enhanced by alleviating the loss of soluble intermediates (polysulfides) into the electrolyte, as well as the side reaction of polysulfides with metallic lithium. The Li-S battery assembled with the interlayer exhibits a large capacity and excellent capacity retention. Therefore, the porous carbon paper as interlayer plays a bifunctional role in stabilizing the Li anode and enhancing the electrochemical performance of the sulfur cathode for constructing a stable Li-S battery.

  3. TARDEC Brief to OnPoint Technologies

    DTIC Science & Technology

    2007-02-28

    in Aberdeen, MD with Lithium - ion battery packs. - The vehicle will undergo many tests using a 15kW-hr battery pack. 30 Other Battery Related...battery, operation requires that the battery be maintained in a heated condition. NiMH - NiMH is the first fall back position after the Lithium Ion battery chemistry

  4. Overview of results from the WaterTox intercalibration and environmental testing phase II program: part 2, ecotoxicological evaluation of drinking water supplies.

    PubMed

    Diaz-Baez, M C; Sánchez, W A; Dutka, B J; Ronco, A; Castillo, G; Pica-Granados, Y; Castillo, L E; Ridal, J; Arkhipchuk, V; Srivastava, R C

    2002-01-01

    Because of rapid population growth, industrial development, and intensified agricultural production increasing amounts of chemicals are being released into the environment, polluting receiving water bodies around the world. Given the potential health risk associated with the presence of toxicants in water sources used for drinking yet the scarcity of available data, there is a need to evaluate these waters and develop strategies to reduce and prevent their contamination. The present study examined the applicability of a battery of simple, inexpensive bioassays in environmental management and the relevance of the test results in establishing the toxicological quality of water sources and drinking water within the framework of the eight-country WaterTox Network, sponsored by the International Development Research Centre, Ottawa, Canada. Seventy-six samples were collected from surface and groundwater sources and seven samples from drinking water treatment plants. Each sample was tested with a core battery of bioassays (Daphnia magna, Hydra attenuata, and Lactuca sativa root inhibition tests) and a limited set of physical and chemical parameters. In addition, three labs included the Selenastrum capricornutum test. When no toxic effects were found with the battery, samples were concentrated 10x using a solid-phase extraction (SPE) procedure. Nonconcentrated natural water samples produced a toxic response in 24% of cases with all three core bioassays. When all bioassays are considered, the percentage of raw samples showing toxicity with at least one bioassay increased to 60%. Of seven treated drinkingwater samples, four showed toxicity with at least one bioassay, raising the possibility that treatment processes in these instances were unable to remove toxic contaminants. The Daphnia magna and Hydra attenuata tests indicated a high level of sensitivity overall. Although only three of the eight countries used S. capricornutum, it proved to be an efficient and reliable bioassay for toxicity assessment. Copyright 2002 Wiley Periodicals, Inc.

  5. International Space Station Lithium-Ion Battery

    NASA Technical Reports Server (NTRS)

    Dalton, Penni J.; Schwanbeck, Eugene; North, Tim; Balcer, Sonia

    2016-01-01

    The International Space Station (ISS) primary Electric Power System (EPS) currently uses Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. Since the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. When deployed, they will be the largest Li-Ion batteries ever utilized for a human-rated spacecraft. This paper will include an overview of the ISS Li-Ion battery system architecture, the Li-Ion battery design and development, controls to limit potential hazards from the batteries, and the status of the Li-Ion cell and ORU life cycle testing.

  6. End User Acceptance - Requirements or Specifications, Certification, Testing

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith

    2013-01-01

    NASA follows top level safety requirement of two-failure tolerance (t hree levels of controls or design for minimum risk) to all catastroph ic hazards in the design of safe li-ion batteries for space use. ? R igorous development testing at appropriate levels to credible offnominal conditions and review of test data. ? Implement robust design con trols based on test results and test again to confirm safety at the a ppropriate levels. ? Stringent testing of all (100%) flight batteries (from button cells to large batteries).

  7. The effect of cell design and test criteria on the series/parallel performance of nickel cadmium cells and batteries

    NASA Technical Reports Server (NTRS)

    Halpert, G.; Webb, D. A.

    1983-01-01

    Three batteries were operated in parallel from a common bus during charge and discharge. SMM utilized NASA Standard 20AH cells and batteries, and LANDSAT-D NASA 50AH cells and batteries of a similar design. Each battery consisted of 22 series connected cells providing the nominal 28V bus. The three batteries were charged in parallel using the voltage limit/current taper mode wherein the voltage limit was temperature compensated. Discharge occurred on the demand of the spacecraft instruments and electronics. Both flights were planned for three to five year missions. The series/parallel configuration of cells and batteries for the 3-5 yr mission required a well controlled product with built-in reliability and uniformity. Examples of how component, cell and battery selection methods affect the uniformity of the series/parallel operation of the batteries both in testing and in flight are given.

  8. Parameters of Emotional Processing in Neuropsychiatric Disorders: Conceptual Issues and a Battery of Tests.

    ERIC Educational Resources Information Center

    Borod, Joan C.; And Others

    1990-01-01

    Components of emotional processing (communication channel, processing mode, and emotional valence) were examined in psychiatric and neurological populations, using an experimental affect battery. The test battery exhibited good psychometric properties and discriminated among diagnostic groups. (Author/JDD)

  9. Performances on the CogState and standard neuropsychological batteries among HIV patients without dementia.

    PubMed

    Overton, Edgar Turner; Kauwe, John S K; Paul, Robert; Tashima, Karen; Tate, David F; Patel, Pragna; Carpenter, Charles C J; Patty, David; Brooks, John T; Clifford, David B

    2011-11-01

    HIV-associated neurocognitive disorders remain prevalent but challenging to diagnose particularly among non-demented individuals. To determine whether a brief computerized battery correlates with formal neurocognitive testing, we identified 46 HIV-infected persons who had undergone both formal neurocognitive testing and a brief computerized battery. Simple detection tests correlated best with formal neuropsychological testing. By multivariable regression model, 53% of the variance in the composite Global Deficit Score was accounted for by elements from the brief computerized tool (P < 0.01). These data confirm previous correlation data with the computerized battery. Using the five significant parameters from the regression model in a Receiver Operating Characteristic curve, 90% of persons were accurately classified as being cognitively impaired or not. The test battery requires additional evaluation, specifically for identifying persons with mild impairment, a state upon which interventions may be effective.

  10. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1993-03-01

    Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.

  11. Evaluating Maintenance Performance: The Development and Tryout of Criterion Referenced Job Task Performance Tests for Electronic Maintenance. Final Report for Period January 1969-May 1974.

    ERIC Educational Resources Information Center

    Shriver, Edgar L.; Foley, John P., Jr.

    A battery of criterion referenced job task performance tests (JIPT) for typical electronic maintenance activities were developed. The construction of a battery of such tests together with an appropriate scoring for reporting the results is detailed. The development of a Test Administrators Handbook also is described. This battery is considered to…

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richter, Daena Kei

    On 6/26/2015 at 1445 in 894/136, a thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following a routine test where the battery is activated. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another containment box within the same room; initial indications are that the battery package ruptured after it went into thermal runaway which led to the operator receiving bruising to the palm of the hand from the pressure of the expulsion. The operator was wearing the prescribed PPE, which was safety glassesmore » and a high temperature glove on the hand that was holding the battery.« less

  13. Prismatic sealed nickel-cadmium batteries utilizing fiber structured electrodes. II - Applications as a maintenance free aircraft battery

    NASA Astrophysics Data System (ADS)

    Anderman, Menahem; Benczur-Urmossy, Gabor; Haschka, Friedrich

    Test data on prismatic sealed Ni-Cd batteries utilizing fiber structured electrodes (sealed FNC) is discussed. It is shown that, under a voltage limited charging scheme, the charge acceptance of the sealed FNC battery is far superior to that of the standard vented aircraft Ni-Cd batteries. This results in the sealed FNC battery maintaining its capacity over several thousand cycles without any need for electrical conditioning or water topping. APU start data demonstrate superior power capabilities over existing technologies. Performance at low temperature is presented. Abuse test results reveal a safe fail mechanism even under severe electrical abuse.

  14. A material flow of lithium batteries in Taiwan.

    PubMed

    Chang, T C; You, S J; Yu, B S; Yao, K F

    2009-04-30

    Li batteries, including secondary and cylindrical/button primary Li batteries, are used worldwide in computers, communications and consumer electronics products. However, there are several dangerous issues that occur during the manufacture, shipping, and storage of Li batteries. This study analyzes the material flow of lithium batteries and their valuable heavy metals in Taiwan for the year 2006 by material flow analysis. According to data from the Taiwan Environmental Protection Administration, Taiwan External Trade Development Council, Bureau of Foreign Trade, Directorate General of Customs, and the Li batteries manufactures/importers/exporters. It was found that 2,952,696 kg of Li batteries was input into Taiwan for the year 2006, including 2,256,501 kg of imported Li batteries and 696,195 kg of stock Li batteries in 2005. In addition, 1,113,867 and 572,215 kg of Li batteries was domestically produced and sold abroad, revealing that 3,494,348 kg of different types of Li batteries was sold in Taiwan. Of these domestically sold batteries, 504,663 and 146,557 kg were treated domestically and abroad. Thus, a total of 2,843,128 kg of Li batteries was stored by individual/industry users or illegally disposed. In addition, it was also observed that 2,120,682 kg of heavy metals contained in Li batteries, including Ni, Co, Al, Cu and Ni, was accumulated in Taiwan, with a recycled value of 38.8 million USD. These results suggest that these heavy metals should be recovered by suitable collection, recycling and reuse procedures.

  15. Results of advanced battery technology evaluations for electric vehicle applications

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1992-10-01

    Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis and Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during 1991-1992 on both single cells and multi-cell modules that encompass eight battery technologies (Na/S, Li/MS (M=metal), Ni/MH, Ni/Cd, Ni/Zn, Ni/Fe, Zn/Br, and Pb-acid). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most-promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.

  16. Crane Cell Testing Support of NASA/Goddard Space Flight Center: An Update

    NASA Technical Reports Server (NTRS)

    Strawn, Mike; David, Jerry; Rao, Gopalakrishna M.

    2001-01-01

    The objectives presented in this viewgraph presentation include: 1) Verify the quality and reliability of aerospace battery cells and batteries for NASA flight programs; 2) Disseminate the data to develop a plan for in-orbit battery management and to design a cell/battery for future NASA spacecraft; and 3) Establish a cell test data base for rechargeable cell/batteries. In summary: quality EPT Ni-H2, EPT Super NiCd and SAFT NiCd cells have been demonstrated for aerospace applications; the data has been provided to NASA Centers and other agencies for their use and application; developed plan and used in NASA in-orbit battery management. Database on rechargeable cell/batteries is now available for customer use.

  17. Deep reconditioning of batteries during DSCS 3 flight operations

    NASA Technical Reports Server (NTRS)

    Thierfelder, H. E.; Stearns, R. J.; Jones, P. W.

    1985-01-01

    Deep reconditioning of batteries is defined as discharge below the 1.0 volt/cell level to a value of about 1.0 volt/battery. This type of reconditioning was investigated for use on the Defense Satellite Communications System (DSCS) spacecraft, and has been used during the first year of orbital operation. Prior to launch of the spacecraft, the deep reconditioning was used during the battery life test, which has now complete fourteen eclipse periods. Reconditioning was performed prior to each eclipse period of the life test, and is scheduled to be used prior to each eclipse period in orbit. The battery data for discharge and recharge is presented for one of the life test reconditioning cycles, and for each of the three batteries during the reconditioning cycles between eclipse period no.1 and eclipse period no.2 in Earth orbit.

  18. Sensitivity of the Halstead and Wechsler Test Batteries to brain damage: Evidence from Reitan's original validation sample.

    PubMed

    Loring, David W; Larrabee, Glenn J

    2006-06-01

    The Halstead-Reitan Battery has been instrumental in the development of neuropsychological practice in the United States. Although Reitan administered both the Wechsler-Bellevue Intelligence Scale and Halstead's test battery when evaluating Halstead's theory of biologic intelligence, the relative sensitivity of each test battery to brain damage continues to be an area of controversy. Because Reitan did not perform direct parametric analysis to contrast group performances, we reanalyze Reitan's original validation data from both Halstead (Reitan, 1955) and Wechsler batteries (Reitan, 1959a) and calculate effect sizes and probability levels using traditional parametric approaches. Eight of the 10 tests comprising Halstead's original Impairment Index, as well as the Impairment Index itself, statistically differentiated patients with unequivocal brain damage from controls. In addition, 13 of 14 Wechsler measures including Full-Scale IQ also differed statistically between groups (Brain Damage Full-Scale IQ = 96.2; Control Group Full Scale IQ = 112.6). We suggest that differences in the statistical properties of each battery (e.g., raw scores vs. standardized scores) likely contribute to classification characteristics including test sensitivity and specificity.

  19. Comparison of Battery Life Across Real-World Automotive Drive-Cycles (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, K.; Earleywine, M.; Wood, E.

    2011-11-01

    Laboratories run around-the-clock aging tests to try to understand as quickly as possible how long new Li-ion battery designs will last under certain duty cycles. These tests may include factors such as duty cycles, climate, battery power profiles, and battery stress statistics. Such tests are generally accelerated and do not consider possible dwell time at high temperatures and states-of-charge. Battery life-predictive models provide guidance as to how long Li-ion batteries may last under real-world electric-drive vehicle applications. Worst-case aging scenarios are extracted from hundreds of real-world duty cycles developed from vehicle travel surveys. Vehicles examined included PHEV10 and PHEV40 EDVsmore » under fixed (28 degrees C), limited cooling (forced ambient temperature), and aggressive cooling (20 degrees C chilled liquid) scenarios using either nightly charging or opportunity charging. The results show that battery life expectancy is 7.8 - 13.2 years for the PHEV10 using a nightly charge in Phoenix, AZ (hot climate), and that the 'aggressive' cooling scenario can extend battery life by 1-3 years, while the 'limited' cooling scenario shortens battery life by 1-2 years. Frequent (opportunity) charging can reduce battery life by 1 year for the PHEV10, while frequent charging can extend battery life by one-half year.« less

  20. Reliability and validity of the Arabic version of the computerized Battery for Neuropsychological Evaluation of Children (BENCI).

    PubMed

    Fasfous, Ahmed F; Peralta-Ramirez, Maria Isabel; Pérez-Marfil, María Nieves; Cruz-Quintana, Francisco; Catena-Martinez, Andrés; Pérez-García, Miguel

    2015-01-01

    Batería de Evaluación Neuropsicológica Infantil (BENCI) is a computerized battery for the neuropsychological evaluation of children. This battery has been used in different studies to evaluate neuropsychological functions and neurodevelopment in children. The objective of this study is to test the validity and reliability of the first Arabic version of the BENCI on an Arabic population where neuropsychological tests are very scarce. We administrate the BENCI to 198 school-age children (98 boys and 100 girls) from Morocco. To examine the test retest reliability of the BENCI battery, we administered the battery 2 times to 43 children (23 boys and 20 girls) with 15 days in between the pre- and posttest. The results revealed good validity and reliability of the battery in Arabic children. Also, the BENCI battery has demonstrated the capacity to differentiate between children by their age group. This battery can be of great use to both the research and clinical areas of Arabic countries and/or in assistance to Arabic immigrants that live outside of their native country.

  1. Solar photovoltaic charging of lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Gibson, Thomas L.; Kelly, Nelson A.

    Solar photovoltaic (PV) charging of batteries was tested by using high efficiency crystalline and amorphous silicon PV modules to recharge lithium-ion battery modules. This testing was performed as a proof of concept for solar PV charging of batteries for electrically powered vehicles. The iron phosphate type lithium-ion batteries were safely charged to their maximum capacity and the thermal hazards associated with overcharging were avoided by the self-regulating design of the solar charging system. The solar energy to battery charge conversion efficiency reached 14.5%, including a PV system efficiency of nearly 15%, and a battery charging efficiency of approximately 100%. This high system efficiency was achieved by directly charging the battery from the PV system with no intervening electronics, and matching the PV maximum power point voltage to the battery charging voltage at the desired maximum state of charge for the battery. It is envisioned that individual homeowners could charge electric and extended-range electric vehicles from residential, roof-mounted solar arrays, and thus power their daily commuting with clean, renewable solar energy.

  2. Relative and absolute reliability of the clinical version of the Narrow Path Walking Test (NPWT) under single and dual task conditions.

    PubMed

    Gimmon, Yoav; Jacob, Grinshpon; Lenoble-Hoskovec, Constanze; Büla, Christophe; Melzer, Itshak

    2013-01-01

    Decline in gait stability has been associated with increased fall risk in older adults. Reliable and clinically feasible methods of gait instability assessment are needed. This study evaluated the relative and absolute reliability and concurrent validity of the testing procedure of the clinical version of the Narrow Path Walking Test (NPWT) under single task (ST) and dual task (DT) conditions. Thirty independent community-dwelling older adults (65-87 years) were tested twice. Participants were instructed to walk within the 6-m narrow path without stepping out. Trial time, number of steps, trial velocity, number of step errors, and number of cognitive task errors were determined. Intraclass correlation coefficients (ICCs) were calculated as indices of agreement, and a graphic approach called "mountain plot" was applied to help interpret the direction and magnitude of disagreements between testing procedures. Smallest detectable change and smallest real difference (SRD) were computed to determine clinically relevant improvement at group and individual levels, respectively. Concurrent validity was assessed using Performance Oriented Mobility Assessment Tool (POMA) and the Short Physical Performance Battery (SPPB). Test-retest agreement (ICC1,2) varied from 0.77 to 0.92 in ST and from 0.78 to 0.92 in DT conditions, with no apparent systematic differences between testing procedures demonstrated by the mountain plot graphs. Smallest detectable change and smallest real change were small for motor task performance and larger for cognitive errors. Significant correlations were observed for trial velocity and trial time with POMA and SPPB. The present results indicate that the NPWT testing procedure is highly reliable and reproducible. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Accelerated cycle life performance for ovonic nickel-metal hydride cells

    NASA Technical Reports Server (NTRS)

    Otzinger, Burton M.

    1991-01-01

    Nickel-Metal Hydride (Ni-MH) rechargeable batteries have emerged as the leading candidate for commercial replacement of nickel-cadmium (Ni-Cd) batteries. An important incentive is that the Ni-MH cell provides approximately twice the capacity of a Ni-Cd cell for a given size. A six-cell battery was committed to an accelerated cycle life test to determine the effect of separation type on performance. Results of the test may also show the Ni-MH battery to be a replacement candidate for the aerospace Ni-Cd battery.

  4. Characterization of the physico-chemical properties of polymeric materials for aerospace flight. [differential thermal and atomic absorption spectroscopic analysis of nickel cadmium batteries

    NASA Technical Reports Server (NTRS)

    Rock, M.

    1981-01-01

    Electrodes and electrolytes of nickel cadmium sealed batteries were analyzed. Different thermal analysis of negative and positive battery electrodes was conducted and the temperature ranges of occurrence of endotherms indicating decomposition of cadmium hydroxide and nickel hydroxide are identified. Atomic absorption spectroscopy was used to analyze electrodes and electrolytes for traces of nickel, cadmium, cobalt, and potassium. Calibration curves and data are given for each sample analyzed. Instrumentation and analytical procedures used for each method are described.

  5. Accelerated test program for sealed nickel-cadmium spacecraft batteries/cells

    NASA Technical Reports Server (NTRS)

    Goodman, L. A.

    1976-01-01

    The feasibility was examined of inducing an accelerated test on sealed Nickel-Cadmium batteries or cells as a tool for spacecraft projects and battery users to determine: (1) the prediction of life capability; (2) a method of evaluating the effect of design and component changes in cells; and (3) a means of reducing time and cost of cell testing.

  6. Performances on the CogState and Standard Neuropsychological Batteries Among HIV Patients Without Dementia

    PubMed Central

    Overton, Edgar Turner; Kauwe, John S.K.; Paul, Rob; Tashima, Karen; Tate, David F.; Patel, Pragna; Carpenter, Chuck; Patty, David; Brooks, John T.; Clifford, David B

    2013-01-01

    HIV-associated neurocognitive disorders (HAND) remain prevalent but challenging to diagnose particularly among non-demented individuals. To determine whether a brief computerized battery correlates with formal neurocognitive testing, we identified 46 HIV-infected persons who had undergone both formal neurocognitive testing and a brief computerized battery. Simple detection tests correlated best with formal neuropsychological testing. By multivariable regression model, 53% of the variance in the composite Global Deficit Score was accounted for by elements from the brief computerized tool (p<0.01). These data confirm previous correlation data with the computerized battery, yet illustrate remaining challenges for neurocognitive screening. PMID:21877204

  7. Long Term Performance Retention Test Using High Power COTS NiCd and NiMH Cells

    NASA Technical Reports Server (NTRS)

    Hall, Dan; Darcy, Eric; Strangways, Brad; Nelson, Tim

    2003-01-01

    This slide presentation reviews the tests and results for performance retention of high powered commercial off the shelf (COTS) NiCd, and NiMH cells. Electromechanical actuators for space flight requires short duration high power batteries. The concern is that NiCd battery designs demonstrate an unfavorable power degradation after long periods of inactivity. Cycling can recover some of the decay, but this reduces the readiness that these batteries must have. Two 5-cell SubC stick test batteries ere chosen using NiCd and NiMH were tested and then the differences for charge maintenance were compared.

  8. Laboratory facility for testing electric-vehicle batteries Test rig for simulating duty cycles with different discharge modes

    NASA Astrophysics Data System (ADS)

    Hamilton, J. A.; Rand, D. A. J.

    1983-03-01

    A test rig has been designed and constructed to examine the performance of batteries under laboratory conditions that simulate the power characteristics of electric vehicles. Each station in the rig subjects a battery to continuous charge/discharge cycles, with an equalising charge every eighth cycle. The battery discharge follows the current-verse-time profile of a given vehicle operating under a driving schedule normal to road service. The test rig allows both smooth- and pulsed-current discharge to be investigated. Data collection is accomplished either with multi-pen recorders or with a computer-based information logger.

  9. The clinical utility of a 30-minute neuropsychological assessment battery in inpatient stroke rehabilitation.

    PubMed

    Jaywant, Abhishek; Toglia, Joan; Gunning, Faith M; O'Dell, Michael W

    2018-07-15

    Cognitive assessment is an important component of inpatient stroke rehabilitation. Few studies have empirically evaluated the clinical utility of specific neuropsychological measures in this setting. We investigated the psychometric properties and clinical utility of a 30-minute neuropsychological battery developed by the National Institute of Neurologic Disorders and Stroke (NINDS) and the Canadian Stroke Network (CSN). Clinical data were analyzed from 100 individuals with mild-moderate stroke severity on an acute inpatient rehabilitation unit who completed the NINDS-CSN battery at admission. The battery comprised the Symbol-Digit Modalities Test (SDMT), Trail Making Test, Controlled Oral Word Association Test, Animal Naming, and the Hopkins Verbal Learning Test-Revised. We evaluated the battery's distribution of scores, frequency of impaired performance, internal consistency, and ability to predict rehabilitation gain and independence in cognitively-based instrumental activities of daily living (IADL) at discharge. Results indicated that the NINDS-CSN battery was sensitive to cognitive impairment, demonstrated moderately strong internal consistency, and predicted discharge IADL. The SDMT demonstrated the strongest sensitivity to impairment and predictive validity. The NINDS-CSN battery is a clinically useful assessment battery in acute inpatient stroke rehabilitation. Complex attention and processing speed performance may be most informative in predicting amount of rehabilitation gain and IADL functioning at discharge. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Common pressure vessel battery performance

    NASA Technical Reports Server (NTRS)

    Otzinger, B.

    1978-01-01

    Performance tests run on two common pressure vessel type nickel hydrogen batteries are described and the results presented. The study included: (1) charge retention tests, (2) synchronous eclipse season cycling tests, and (3) temperature differential tests.

  11. Impaired performance on a rhesus monkey neuropsychological testing battery following simian immunodeficiency virus infection.

    PubMed

    Weed, Michael R; Gold, Lisa H; Polis, Ilham; Koob, George F; Fox, Howard S; Taffe, Michael A

    2004-01-01

    Infection with simian immunodeficiency virus (SIV) in macaques provides an excellent model of AIDS including HIV-induced central nervous system (CNS) pathology and cognitive/behavioral impairment. Recently a behavioral test battery has been developed for macaques based on the CANTAB human neuropsychological testing battery. As with human neuropsychological batteries, different tasks are thought to involve different neural substrates, and therefore performance profiles may assess function in particular brain regions. Ten rhesus monkeys were infected with SIV after being trained on two or more of the battery tasks addressing memory (delayed nonmatching to sample, DNMS), spatial working memory (using a self-ordered spatial search task, SOSS), motivation (progressive-ratio, PR), reaction time (RT), and/or fine motor skills (bimanual motor skill, BMS). Performance was compared to that of 9 uninfected monkeys. Overall, some aspect of performance was impaired in all 10 monkeys following infection. Consistent with results in human AIDS patients, individual performance was impaired most often on battery tasks thought to be sensitive to frontostriatal dopaminergic functioning such as SOSS, RT, and BMS. These results further demonstrate the similarity of behavioral impairment produced by SIV and HIV on homologous behavioral tests, and establish the utility of the testing battery for further investigations into the CNS mechanisms of the reported behavioral changes.

  12. Design of a testing strategy using non-animal based test methods: lessons learnt from the ACuteTox project.

    PubMed

    Kopp-Schneider, Annette; Prieto, Pilar; Kinsner-Ovaskainen, Agnieszka; Stanzel, Sven

    2013-06-01

    In the framework of toxicology, a testing strategy can be viewed as a series of steps which are taken to come to a final prediction about a characteristic of a compound under study. The testing strategy is performed as a single-step procedure, usually called a test battery, using simultaneously all information collected on different endpoints, or as tiered approach in which a decision tree is followed. Design of a testing strategy involves statistical considerations, such as the development of a statistical prediction model. During the EU FP6 ACuteTox project, several prediction models were proposed on the basis of statistical classification algorithms which we illustrate here. The final choice of testing strategies was not based on statistical considerations alone. However, without thorough statistical evaluations a testing strategy cannot be identified. We present here a number of observations made from the statistical viewpoint which relate to the development of testing strategies. The points we make were derived from problems we had to deal with during the evaluation of this large research project. A central issue during the development of a prediction model is the danger of overfitting. Procedures are presented to deal with this challenge. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Analyse Factorielle d'une Batterie de Tests de Comprehension Orale et Ecrite (Factor Analysis of a Battery of Tests of Listening and Reading Comprehension). Melanges Pedagogiques, 1971.

    ERIC Educational Resources Information Center

    Lonchamp, F.

    This is a presentation of the results of a factor analysis of a battery of tests intended to measure listening and reading comprehension in English as a second language. The analysis sought to answer the following questions: (1) whether the factor analysis method yields results when applied to tests which are not specifically designed for this…

  14. Proceedings of the Annual Conference of the Military Testing Association (21st), San Diego, California, 15-19 October 1979

    DTIC Science & Technology

    1979-01-01

    conflicting veathervAbs directions, dietracted by tape drim oral stimali, The paper-pencil battery yas administered to the total amle group at facilities...not just procedural level "walk-throughs." 144t It is the thesis of this paper that the inappropriate use of "objective" or process standards to...Technology give us much help in talkinfi about difficulty. So, I tried another window through which to look at the problem, M’,y thesis is that there is a

  15. International Space Station Lithium-Ion Battery Start-Up

    NASA Technical Reports Server (NTRS)

    Dalton, Penni J.; North, Tim; Bowens, Ebony; Balcer, Sonia

    2017-01-01

    International Space Station Lithium-Ion Battery Start-Up.The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. As the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. The first set of 6 Li-ion battery replacements were launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit start-up and the status of the Li-Ion cell and ORU life cycle testing.

  16. Montreal Battery of Evaluation of Amusia: Validity evidence and norms for adolescents in Belo Horizonte, Minas Gerais, Brazil

    PubMed Central

    Nunes-Silva, Marília; Haase, Vitor Geraldi

    2012-01-01

    The Montreal Battery of Evaluation of Amusia (MBEA) is a battery of tests that assesses six music processing components: scale, contour, interval, rhythm, metric, and music memory. The present study sought to verify the psychometric characteristics of the MBEA in a sample of 150 adolescents aged 14-18 years in the city of Belo Horizonte, Minas Gerais, Brazil, and to develop specific norms for this population. We used statistical procedures that explored the dimensional structure of the MBEA and its items, evaluating their adequacy from empirical data, verifying their reliability, and providing evidence of validity. The results for the difficult levels for each test indicated a trend toward higher scores, corroborating previous studies. From the analysis of the criterion groups, almost all of the items were considered discriminatory. The global score of the MBEA was shown to be valid and reliable (rK-R20=0.896) for assessing the musical ability of normal teenagers. Based on the analysis of the items, we proposed a short version of the MBEA. Further studies with larger samples and amusic individuals are necessary to provide evidence of the validity of the MBEA in the Brazilian milieu. The present study brings to the Brazilian context a tool for diagnosing deficits in musical skills and will serve as a basis for comparisons with single case studies and studies of populations with specific neuropsychological syndromes. PMID:29213804

  17. The challenge of testing chemicals for potential carcinogenicity using multiple short-term assays: an analysis of a proposed test battery for hair dyes.

    PubMed

    Rosenkranz, Herbert S; Cunningham, Suzanne L; Mermelstein, Robert; Cunningham, Albert R

    2007-09-01

    Recent reports of the association of hair dyes usage with increased bladder cancer risk in women with the slow NAT-2 acetylator phenotype have resulted both in attempts to identify the putative carcinogen as well as in devising batteries of tests that could be used to screen for such putative carcinogens in hair dye formulations, their intermediates and final products. Analytical studies have reported the presence of traces ( approximately 0.5 ppm) of the carcinogen 4-aminobiphenyl in some hair dye preparations. In parallel, SCCNFP (Scientific Committee on Cosmetic and Non-Food Products Intended for Consumers) has suggested the deployment of a battery of six in vitro assays followed by an in vivo assay. The practicality of deploying and interpreting such a battery is analyzed herein as it is expected to result in 64 and 128 possible test results and SCCNFP does not provide detailed guidance of how the test results are to be interpreted. In this study we have applied a previously described Bayesian approach which takes advantage of the known predictive performances of individual assays, to analyze the possible outcomes of the 6-7 test batteries. While the SCCNFP battery is clearly risk-averse, it is shown that performing all of the assays is not always necessary and moreover it does not necessarily improve predictive performance. Finally, based upon the reported mutagenicity of 4-aminobiphenyl, it is doubtful that this "impurity" would be detected by the test battery.

  18. The Long-Term Performance of SONY Small Batteries without Cell-Balancing

    NASA Technical Reports Server (NTRS)

    Pearson, Chris; Thwaite, Carl; Curzon, David; Rao, Gopalakrishna

    2004-01-01

    This viewgraph presentation describes the investigation of individual cell voltage dispersion under LEO and GEO cycling profiles. The contents cover: 1) Background; 2) Test Outline; 3) Single String Test Battery; 4) Goddard Space Flight Center (GSFC) 5Ah Battery; 5) Impedance; 6) Conclusions.

  19. Steady-state and dynamic evaluation of the electric propulsion system test bed vehicle on a road load simulator

    NASA Technical Reports Server (NTRS)

    Dustin, M. O.

    1983-01-01

    The propulsion system of the Lewis Research Center's electric propulsion system test bed vehicle was tested on the road load simulator under the DOE Electric and Hybrid Vehicle Program. This propulsion system, consisting of a series-wound dc motor controlled by an infinitely variable SCR chopper and an 84-V battery pack, is typical of those used in electric vehicles made in 1976. Steady-state tests were conducted over a wide range of differential output torques and vehicle speeds. Efficiencies of all of the components were determined. Effects of temperature and voltage variations on the motor and the effect of voltage changes on the controller were examined. Energy consumption and energy efficiency for the system were determined over the B and C driving schedules of the SAE J227a test procedure.

  20. Comparison Between a Self-Administered and Supervised Version of a Web-Based Cognitive Test Battery: Results From the NutriNet-Santé Cohort Study.

    PubMed

    Assmann, Karen E; Bailet, Marion; Lecoffre, Amandine C; Galan, Pilar; Hercberg, Serge; Amieva, Hélène; Kesse-Guyot, Emmanuelle

    2016-04-05

    Dementia is a major public health problem, and repeated cognitive data from large epidemiological studies could help to develop efficient measures of early prevention. Data collection by self-administered online tools could drastically reduce the logistical and financial burden of such large-scale investigations. In this context, it is important to obtain data concerning the comparability of such new online tools with traditional, supervised modes of cognitive assessment. Our objective was to compare self-administration of the Web-based NutriNet-Santé cognitive test battery (NutriCog) with administration by a neuropsychologist. The test battery included four tests, measuring, among others aspects, psychomotor speed, attention, executive function, episodic memory, working memory, and associative memory. Both versions of the cognitive battery were completed by 189 volunteers (either self-administered version first, n=99, or supervised version first, n=90). Subjects also completed a satisfaction questionnaire. Concordance was assessed by Spearman correlation. Agreement between both versions varied according to the investigated cognitive task and outcome variable. Spearman correlations ranged between .42 and .73. Moreover, a majority of participants responded that they "absolutely" or "rather" agreed that the duration of the self-administered battery was acceptable (184/185, 99.5%), that the tasks were amusing (162/185, 87.6%), that the instructions were sufficiently detailed (168/185; 90.8%) and understandable (164/185, 88.7%), and that they had overall enjoyed the test battery (182/185, 98.4%). The self-administered version of the Web-based NutriCog cognitive test battery provided similar information as the supervised version. Thus, integrating repeated cognitive evaluations into large cohorts via the implementation of self-administered online versions of traditional test batteries appears to be feasible.

  1. Toxoplasmosis serology: an efficient hemagglutination procedure to detect IgG and IgM antibodies.

    PubMed

    Camargo, M E; Moura, M E; Leser, P G

    1989-01-01

    In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo, an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A--rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.

  2. Status of SPV/CPV Testing

    NASA Technical Reports Server (NTRS)

    Brown, Harry; Hall, Steve

    1999-01-01

    This presentation reviews the status test of Single Pressure Vessel (SPV)/Common Pressure Vessel (CPV) being conducted by the Navy. Slides review the design and tests by NASA, and the Airforce of CPV's. There are 5 different CPV models of CPV's which have been tested or are currently being tested for NASA and the Air Force. The batteries, tests, and results are presented. Graphs show the life cycle voltage, the pressure trend, the discharge/charge profile and the pressure profile for the batteries tested. Descriptions of those CPV batteries are given for those batteries which have been received but have not been tested. The development of the SPV is briefly described, followed by design specification for two packs from NASA and the Air Force. The acceptance test criteria are reviewed, followed by a review of the life cycle test conditions. The trend plots of voltage vs. cycle is given for the two packs. The end of charge, and the end of discharge voltages plots are shown. Plots showing the pressure and recharge vs. cycle are shown. Plots also show the voltage profiles. These plots are shown for both batteries using the SPV design submitted by NASA and the Air Force.

  3. Lessons learned in acquiring new regulations for shipping advanced electric vehicle batteries

    NASA Astrophysics Data System (ADS)

    Henriksen, Gary; Hammel, Carol; Altemos, Edward A.

    1994-12-01

    In 1990, the Electric and Hybrid Propulsion Division of the US Department of Energy established its ad hoc EV Battery Readiness Working Group to identify regulatory barriers to the commercialization of advanced EV battery technologies and facilitate the removal of these barriers. A Shipping Sub-Working Group (SSWG) was formed to address the regulatory issues associated with the domestic and international shipment of these new battery technologies. The SSWG invites major industrial developers of advanced battery technologies to join as members and work closely with appropriate domestic and international regulatory authorities to develop suitable regulations and procedures for the safe transport of these new battery technologies. This paper describes the domestic and international regulatory processes for the transport of dangerous goods; reviews the status of shipping regulations for sodium-beta and lithium batteries; and delineates the lessons learned to date in this process. The sodium-beta battery family was the first category of advanced EV batteries to be addressed by the SSWG. It includes both sodium/sulfur and sodium/metal chloride batteries. Their efforts led to the establishment of a UN number (UN 3292) in the UN Recommendations, for cold cells and batteries, and establishment of a US Department of Transportation general exemption (DOT-E-10917) covering cold and hot batteries, as well as cold cells. The lessons learned for sodium-beta batteries, over the period of 1990--94, are now being applied to the development of regulations for shipping a new generation of lithium battery technologies (lithium-polymer and lithium-aluminum/iron sulfide batteries).

  4. Design, Build and Qualification of 28 Volt Lithium-Ion battery

    NASA Technical Reports Server (NTRS)

    Curzon, D.; Spurrett, R.; Rao, G.

    2003-01-01

    Contents include the following: 1. GSFC performance specifications requirements. 2. AEA philosophy: battery configuration. 3. AEA battery design: SONY cell, cell screening, 20Ah and 60Ah. 4. Testing: 20Ah battery qualification (environmental); 60Ah battery LEO life cycle. 5. Conclusion.: summary and lessons learned.

  5. Development and Evaluation of Active Thermal Management System for Lithium-Ion Batteries using Solid-State Thermoelectric Heat Pump and Heat Pipes with Electric Vehicular Applications

    NASA Astrophysics Data System (ADS)

    Parekh, Bhaumik Kamlesh

    Lithium-Ion batteries have become a popular choice for use in energy storage systems in electric vehicles (EV) and Hybrid electric vehicles (HEV) because of high power and high energy density. But the use of EV and HEV in all climates demands for a battery thermal management system (BTMS) since temperature effects their performance, cycle life and, safety. Hence the BTMS plays a crucial role in the performance of EV and HEV. In this paper, three thermal management systems are studied: (a) simple aluminum as heat spreader material, (b) heat pipes as heat spreader, and (c) advanced combined solid state thermoelectric heat pump (TE) and heat pipe system; these will be subsequently referred to as Design A, B and C, respectively. A detailed description of the designs and the experimental setup is presented. The experimental procedure is divided into two broad categories: Cooling mode and Warming-up mode. Cooling mode covers the conditions when a BTMS is responsible to cool the battery pack through heat dissipation and Warming-up mode covers the conditions when the BTMS is responsible to warm the battery pack in a low temperature ambient condition, maintaining a safe operating temperature of the battery pack in both modes. The experimental procedure analyzes the thermal management system by evaluating the effect of each variable like heat sink area, battery heat generation rate, cooling air temperature, air flow rate and TE power on parameters like maximum temperature of the battery pack (T max), maximum temperature difference (DeltaT) and, heat transfer through heat sink/cooling power of TE (Q c). The results show that Design C outperforms Design A and Design B in spite of design issues which reduce its efficiency, but can still be improved to achieve better performance.

  6. Screening Li-Ion Batteries for Internal Shorts

    NASA Technical Reports Server (NTRS)

    Darcy, Eric

    2006-01-01

    The extremely high cost of aerospace battery failures due to internal shorts makes it essential that their occurrence be very rare, if not eliminated altogether. With Li-ion cells/batteries, the potentially catastrophic safety hazard that some internal shorts present adds additional incentive for prevention. Prevention can be achieved by design, manufacturing measures, and testing. Specifically for NASA s spacesuit application, a Li-ion polymer pouch cell battery design is in its final stages of production. One of the 20 flight batteries fabricated and tested developed a cell internal short, which did not present a safety hazard, but has required revisiting the entire manufacturing and testing process. Herein are the details of the failure investigation that followed to get to root cause of the internal short and the corrective actions that will be taken. The resulting lessons learned are applicable to most Li-ion battery applications.

  7. The In-Orbit Battery Reconditioning Experience On Board the Orion 1 Spacecraft

    NASA Technical Reports Server (NTRS)

    Hoover, S. A.; Daughtridge, S.; Johnson, P. J.; King, S. T.

    1997-01-01

    The Orion 1 spacecraft is a three-axis stabilized geostationary earth orbiting commercial communications satellite which was launched on November 29, 1994 aboard an Atlas II launch vehicle. The power subsystem is a dual bus, dual battery semi-regulated system with one 78 Ampere-hour nickel-hydrogen battery per bus. The batteries were built and tested by Eagle Picher Industries, Inc., of Joplin, MO and were integrated into the spacecraft by its manufacturer, Matra Marconi Space UK Ltd. This paper presents the results obtained during the first four in-orbit reconditioning cycles and compares the battery performance to ground test data. In addition, the on-station battery management strategy and implementation constraints are described. Battery performance has been nominal throughout each reconditioning cycle and subsequent eclipse season.

  8. The minimum test battery to screen for binocular vision anomalies: report 3 of the BAND study.

    PubMed

    Hussaindeen, Jameel Rizwana; Rakshit, Archayeeta; Singh, Neeraj Kumar; Swaminathan, Meenakshi; George, Ronnie; Kapur, Suman; Scheiman, Mitchell; Ramani, Krishna Kumar

    2018-03-01

    This study aims to report the minimum test battery needed to screen non-strabismic binocular vision anomalies (NSBVAs) in a community set-up. When large numbers are to be screened we aim to identify the most useful test battery when there is no opportunity for a more comprehensive and time-consuming clinical examination. The prevalence estimates and normative data for binocular vision parameters were estimated from the Binocular Vision Anomalies and Normative Data (BAND) study, following which cut-off estimates and receiver operating characteristic curves to identify the minimum test battery have been plotted. In the receiver operating characteristic phase of the study, children between nine and 17 years of age were screened in two schools in the rural arm using the minimum test battery, and the prevalence estimates with the minimum test battery were found. Receiver operating characteristic analyses revealed that near point of convergence with penlight and red filter (> 7.5 cm), monocular accommodative facility (< 10 cycles per minute), and the difference between near and distance phoria (> 1.25 prism dioptres) were significant factors with cut-off values for best sensitivity and specificity. This minimum test battery was applied to a cohort of 305 children. The mean (standard deviation) age of the subjects was 12.7 (two) years with 121 males and 184 females. Using the minimum battery of tests obtained through the receiver operating characteristic analyses, the prevalence of NSBVAs was found to be 26 per cent. Near point of convergence with penlight and red filter > 10 cm was found to have the highest sensitivity (80 per cent) and specificity (73 per cent) for the diagnosis of convergence insufficiency. For the diagnosis of accommodative infacility, monocular accommodative facility with a cut-off of less than seven cycles per minute was the best predictor for screening (92 per cent sensitivity and 90 per cent specificity). The minimum test battery of near point of convergence with penlight and red filter, difference between distance and near phoria, and monocular accommodative facility yield good sensitivity and specificity for diagnosis of NSBVAs in a community set-up. © 2017 Optometry Australia.

  9. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT XII, LEARNING ABOUT BATTERY SERVICING AND TESTING (PART I).

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THID MODULE OF A 25-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE CONSTRUCTION AND MAINTENANCE OF LEAD-ACID STORAGE BATTERIES USED ON DIESEL POWERED EQUIPMENT. TOPICS ARE (1) BATTERY COMPONENTS AND CONSTRUCTION, (2) CHEMICAL ACTION IN BATTERIES, (3) THE BATTERY AND THE CHARGING CIRCUIT, (4) BATTERY CHARGING VOLTAGE, (5) EFFECTS OF…

  10. Evaluation of lower leg function in patients with Achilles tendinopathy.

    PubMed

    Silbernagel, Karin Grävare; Gustavsson, Alexander; Thomeé, Roland; Karlsson, Jon

    2006-11-01

    Achilles tendinopathy is considered to be one of the most common overuse injuries in elite and recreational athletes. However, the effect that the Achilles tendinopathy has on patients' physical performance is still unclear. The purpose of this study was to evaluate if Achilles tendinopathy caused functional deficits on the injured side compared with the non-injured side in patients. A test battery comprised of tests for different aspects of muscle-tendon function of the gastrocnemius, soleus and Achilles tendon complex was developed to evaluate lower leg function. The test battery's test-retest reliability and sensitivity (the percent probability that the tests would demonstrate abnormal lower limb symmetry index in patients) were also evaluated. The test battery consisted of three jump tests, a counter movements jump (CMJ), a drop counter movement jump (drop CMJ) and hopping, and two strength tests, concentric toe-raises, eccentric-concentric toe-raises and toe-raises for endurance. The reliability was evaluated through a test-retest design on 15 healthy subjects. The test battery's sensitivity and possible functional deficits in patients with Achilles tendinopathy were evaluated on 42 patients (19 women and 23 men). An excellent reliability was found between test days 1-2 and 2-3 for all tests (ICC = 0.76-0.94) except for concentric toe-raise, test 2-3, which had fair reliability (ICC = 0.73). The methodological error ranged from 8 to 17%. There were significant differences (P = 0.001-0.049) between the non-injured (or least symptomatic) side and injured (most symptomatic) side for hopping, drop CMJ, concentric and eccentric-concentric toe-raises, and significant differences (P = 0.000-0.012) in the level of pain during CMJ, hopping, and drop CMJ. The sensitivity of the test battery at a 90% capacity was 88. Achilles tendinopathy causes not only pain and symptoms in patients but also apparent impairments in various aspects of lower leg muscle-tendon function as measured with the test battery. This test battery is reliable and able to detect differences in lower leg function between the injured or "most symptomatic" and non-injured or "least symptomatic" side in patients with Achilles tendinopathy. The test battery has higher demand on patients' function compared with each individual test.

  11. Environmental, health, and safety issues of sodium-sulfur batteries for electric and hybrid vehicles. Volume 1, Cell and battery safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohi, J M

    1992-09-01

    This report is the first of four volumes that identify and assess the environmental, health, and safety issues involved in using sodium-sulfur (Na/S) battery technology as the energy source in electric and hybrid vehicles that may affect the commercialization of Na/S batteries. This and the other reports on recycling, shipping, and vehicle safety are intended to help the Electric and Hybrid Propulsion Division of the Office of Transportation Technologies in the US Department of Energy (DOE/EHP) determine the direction of its research, development, and demonstration (RD&D) program for Na/S battery technology. The reports review the status of Na/S battery RD&Dmore » and identify potential hazards and risks that may require additional research or that may affect the design and use of Na/S batteries. This volume covers cell design and engineering as the basis of safety for Na/S batteries and describes and assesses the potential chemical, electrical, and thermal hazards and risks of Na/S cells and batteries as well as the RD&D performed, under way, or to address these hazards and risks. The report is based on a review of the literature and on discussions with experts at DOE, national laboratories and agencies, universities, and private industry. Subsequent volumes will address environmental, health, and safety issues involved in shipping cells and batteries, using batteries to propel electric vehicles, and recycling and disposing of spent batteries. The remainder of this volume is divided into two major sections on safety at the cell and battery levels. The section on Na/S cells describes major component and potential failure modes, design, life testing and failure testing, thermal cycling, and the safety status of Na/S cells. The section on batteries describes battery design, testing, and safety status. Additional EH&S information on Na/S batteries is provided in the appendices.« less

  12. Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability.

    PubMed

    Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T

    2008-12-01

    In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.

  13. Automated Comprehensive Evaluation of mTBI Visual Dysfunction

    DTIC Science & Technology

    2016-10-01

    of this study is to validate the Neuro-Ophthalmic Device (NODe) test battery that provides the highest sensitivity and specificity for the detection...that the tests within the NODe test battery can serve as objective biomarkers for acute mTBI. Two hundred acute mTBI (≤72 hrs post injury) and 200 age...post-mTBI-related vision problems. The purpose of this study is to validate the Neuro-Ophthalmic Device (NODe) test battery that provides the

  14. Validation of a short cognitive battery to screen for fitness-to-drive of people with multiple sclerosis.

    PubMed

    Akinwuntan, A E; Backus, D; Grayson, J; Devos, H

    2018-05-26

    Some symptoms of multiple sclerosis (MS) affect driving. In a recent study, performance on five cognitive tests predicted the on-road test performance of individuals with relapsing-remitting MS with 91% accuracy, 70% sensitivity and 97% specificity. However, the accuracy with which the battery will predict the driving performance of a different cohort that includes all types of MS is unknown. Participants (n = 118; 48 ± 9 years of age; 97 females) performed a comprehensive off-road evaluation that lasted about 3 h and a standardized on-road test that lasted approximately 45 min over a 2-day period within the same week. Performance on the five cognitive tests was used to predict participants' performance on the standardized on-road test. Performance on the five tests together predicted outcome of the on-road test with 82% accuracy, 42% sensitivity and 90% specificity. The accuracy of predicting the on-road performance of a new MS cohort using performance on the battery of five cognitive tests remained very high (82%). The battery, which was administrable in <45 min and cost ~$150, was better at identifying those who actually passed the on-road test (90% specificity). The sensitivity (42%) of the battery indicated that it should not be used as the sole determinant of poor driving-related cognitive skills. A fail performance on the battery should only imply that more comprehensive testing is warranted. © 2018 EAN.

  15. Hubble Space Telescope NiH2 six battery test

    NASA Technical Reports Server (NTRS)

    Whitt, Thomas H.; Lanier, J. Roy

    1991-01-01

    The primary objectives of the test are: (1) to get a better understanding of the operating characteristics of the NiH2 batteries in the Hubble Space Telescope (HST) Electric Power Subsystem (EPS) by simulating every aspect of the expected operating environment; (2) to determine the optimum charge level and charge scheme for the NiH2 batteries in the HST EPS; (3) to predict the performance of the actual HST EPS; (4) to observe the aging characteristics of the batteries; and (5) to test different EPS anomalies before experiencing the anomalies on the actual HST.

  16. ETX-I: First-generation single-shaft electric propulsion system program. Volume 2: Battery

    NASA Astrophysics Data System (ADS)

    1988-06-01

    The overall objective of this research and development program was to advance ac powertrain technology for electric vehicles (EV). The program focused on the design, build, test, and refinement of an experimental advanced electric vehicle powertrain suitable for packaging in a Ford Escort or equivalent-size vehicle. A Mercury LN7 was subsequently selected for the test bed vehicle. Although not part of the initial contract, the scope of the ETX-I Program was expanded in 1983 to encompass the development of advanced electric vehicle batteries compatible with the ETX-I powertrain and vehicle test bed. The intent of the battery portion of the ETX-I Program was to apply the best available battery technology based on existing battery developments. The battery effort was expected to result in a practical scale-up of base battery technologies to the vehicle battery subsystem level. With the addition of the battery activity, the ETX-I Program became a complete proof-of-concept ac propulsion system technology development program. In this context, the term propulsion system is defined as all components and subsystems (from the driver input to the vehicle wheels) that are required to store energy on board the vehicle and, using that energy, to provide controlled motive power to the vehicle. This report, Volume 2, describes the battery portion of the ETX-I Program. The powertrain effort is reported in Volume 1.

  17. The Relationship between Types of Attention and Auditory Processing Skills: Reconsidering Auditory Processing Disorder Diagnosis

    PubMed Central

    Stavrinos, Georgios; Iliadou, Vassiliki-Maria; Edwards, Lindsey; Sirimanna, Tony; Bamiou, Doris-Eva

    2018-01-01

    Measures of attention have been found to correlate with specific auditory processing tests in samples of children suspected of Auditory Processing Disorder (APD), but these relationships have not been adequately investigated. Despite evidence linking auditory attention and deficits/symptoms of APD, measures of attention are not routinely used in APD diagnostic protocols. The aim of the study was to examine the relationship between auditory and visual attention tests and auditory processing tests in children with APD and to assess whether a proposed diagnostic protocol for APD, including measures of attention, could provide useful information for APD management. A pilot study including 27 children, aged 7–11 years, referred for APD assessment was conducted. The validated test of everyday attention for children, with visual and auditory attention tasks, the listening in spatialized noise sentences test, the children's communication checklist questionnaire and tests from a standard APD diagnostic test battery were administered. Pearson's partial correlation analysis examining the relationship between these tests and Cochrane's Q test analysis comparing proportions of diagnosis under each proposed battery were conducted. Divided auditory and divided auditory-visual attention strongly correlated with the dichotic digits test, r = 0.68, p < 0.05, and r = 0.76, p = 0.01, respectively, in a sample of 20 children with APD diagnosis. The standard APD battery identified a larger proportion of participants as having APD, than an attention battery identified as having Attention Deficits (ADs). The proposed APD battery excluding AD cases did not have a significantly different diagnosis proportion than the standard APD battery. Finally, the newly proposed diagnostic battery, identifying an inattentive subtype of APD, identified five children who would have otherwise been considered not having ADs. The findings show that a subgroup of children with APD demonstrates underlying sustained and divided attention deficits. Attention deficits in children with APD appear to be centred around the auditory modality but further examination of types of attention in both modalities is required. Revising diagnostic criteria to incorporate attention tests and the inattentive type of APD in the test battery, provides additional useful data to clinicians to ensure careful interpretation of APD assessments. PMID:29441033

  18. The test-retest reliability of the latent construct of executive function depends on whether tasks are represented as formative or reflective indicators.

    PubMed

    Willoughby, Michael T; Kuhn, Laura J; Blair, Clancy B; Samek, Anya; List, John A

    2017-10-01

    This study investigates the test-retest reliability of a battery of executive function (EF) tasks with a specific interest in testing whether the method that is used to create a battery-wide score would result in differences in the apparent test-retest reliability of children's performance. A total of 188 4-year-olds completed a battery of computerized EF tasks twice across a period of approximately two weeks. Two different approaches were used to create a score that indexed children's overall performance on the battery-i.e., (1) the mean score of all completed tasks and (2) a factor score estimate which used confirmatory factor analysis (CFA). Pearson and intra-class correlations were used to investigate the test-retest reliability of individual EF tasks, as well as an overall battery score. Consistent with previous studies, the test-retest reliability of individual tasks was modest (rs ≈ .60). The test-retest reliability of the overall battery scores differed depending on the scoring approach (r mean  = .72; r factor_ score  = .99). It is concluded that the children's performance on individual EF tasks exhibit modest levels of test-retest reliability. This underscores the importance of administering multiple tasks and aggregating performance across these tasks in order to improve precision of measurement. However, the specific strategy that is used has a large impact on the apparent test-retest reliability of the overall score. These results replicate our earlier findings and provide additional cautionary evidence against the routine use of factor analytic approaches for representing individual performance across a battery of EF tasks.

  19. Data-driven battery product development: Turn battery performance into a competitive advantage.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sholklapper, Tal

    Poor battery performance is a primary source of user dissatisfaction across a broad range of applications, and is a key bottleneck hindering the growth of mobile technology, wearables, electric vehicles, and grid energy storage. Engineering battery systems is difficult, requiring extensive testing for vendor selection, BMS programming, and application-specific lifetime testing. This work also generates huge quantities of data. This presentation will explain how to leverage this data to help ship quality products faster using fewer resources while ensuring safety and reliability in the field, ultimately turning battery performance into a competitive advantage.

  20. Hydrometallurgical treatment of nickel-metal hydride battery electrodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyman, J.W.; Palmer, G.R.

    1995-12-31

    Nickel-metal hydride (Ni-MH) battery electrodes have been developed as a substitute for cadmium-containing negative electrodes. Use of NI-MH electrodes offers enhanced electrochemical properties in many instances as well as reduced environmental toxicity. Rechargeable batteries using NI-MH electrodes are also strong candidates for electric vehicles. During the production and secondary reclamation of these battery types, recycling procedures will be needed to prevent environmental impact caused by these wastes as well as to recover the value inherent in the scrap. The US Bureau of Mines (USBM) is investigating hydrometallurgical technology that separates and recovers purified metallic components from Ni-MH battery scrap ofmore » two types, AB{sub 2} and AB{sub 5}. An investigation of acid dissolution and metal recovery techniques has determined several processing alternatives that may be used to promote the successful recycling of much of the battery fabrication scrap and eventual secondary scrap. The metals recovered are Ni, Co, and rare earth metals. Although recovery techniques have been identified in principal, their applicability to mixed battery waste stream and economic attractiveness remain to be demonstrated.« less

  1. AN ADVANCED CALIBRATION PROCEDURE FOR COMPLEX IMPEDANCE SPECTRUM MEASUREMENTS OF ADVANCED ENERGY STORAGE DEVICES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    William H. Morrison; Jon P. Christophersen; Patrick Bald

    With the increasing demand for electric and hybrid electric vehicles and the explosion in popularity of mobile and portable electronic devices such as laptops, cell phones, e-readers, tablet computers and the like, reliance on portable energy storage devices such as batteries has likewise increased. The concern for the availability of critical systems in turn drives the availability of battery systems and thus the need for accurate battery health monitoring has become paramount. Over the past decade the Idaho National Laboratory (INL), Montana Tech of the University of Montana (Tech), and Qualtech Systems, Inc. (QSI) have been developing the Smart Batterymore » Status Monitor (SBSM), an integrated battery management system designed to monitor battery health, performance and degradation and use this knowledge for effective battery management and increased battery life. Key to the success of the SBSM is an in-situ impedance measurement system called the Impedance Measurement Box (IMB). One of the challenges encountered has been development of an accurate, simple, robust calibration process. This paper discusses the successful realization of this process.« less

  2. Battery/Ultracapacitor Evaluation for X-38 Crew Return Vehicle (CRV)

    NASA Technical Reports Server (NTRS)

    Darcy, Eric; Strangways, Bradley

    1999-01-01

    This presentation reported on the evaluation of the battery/ultracapacitor for the crew return vehicle (CRV). The CRV, as part of the international space station (ISS) planning, will be available to return to earth an ill or injured crew person, or if the ISS becomes unsafe, and the shuttle is not available. The requirements of the X-38 CRV are reviewed, and in light of the power requirements, the battery's required performance is reviewed. The ultracapacitor bank, and its test method is described. The test results are reviewed. A picture of the test set up is displayed showing the ultracapacitor bank and the NiMH battery. The presentation continues by reviewing tests of 5 available trade high power cell designs: (1) Hawker lead acid, (2) Bolder lead acid, (3) Energizer NiMH, (4) Sanyo NiCd, and (5) Energizer NiCd. The test methods and results are reviewed. There is also a review of the issues concerning lead acid batteries and conclusions.

  3. Low Temperature Life-Cycle Testing of a Lithium-Ion Battery for Low-Earth-Orbiting Spacecraft

    NASA Technical Reports Server (NTRS)

    Reid, Concha

    2006-01-01

    A flight-qualified, lithium-ion (Li-ion) battery developed for the Mars Surveyor Program 2001 Landeris undergoing life-testing at low temperature under a low-Earth-orbit (LEO) profile to assess its capability to provide long term energy storage for aerospace missions. NASA has embarked upon an ambitious course to return humans to the moon by 2015-2020 in preparation for robotic and human exploration of Mars and robotic exploration of the moons of outer planets. Li-ion batteries are excellent candidates to provide power and energy storage for multiple aspects of these missions due to their high specific energy, high energy density, and excellent low temperature performance. Laboratory testing of Li-ion technology is necessary in order to assess lifetime, characterize multi-cell battery-level performance under aerospace conditions, and to gauge safety aspects of the technology. Life-cycle testing provides an opportunity to examine battery-level performance and the dynamics of individual cells in the stack over the entire life of the battery. Data generated through this testing will be critical to establish confidence in the technology for its widespread use in manned and unmanned missions.

  4. Charge retention test experiences on Hubble Space Telescope nickel-hydrogen battery cells

    NASA Technical Reports Server (NTRS)

    Nawrocki, Dave E.; Driscoll, J. R.; Armantrout, J. D.; Baker, R. C.; Wajsgras, H.

    1993-01-01

    The Hubble Space Telescope (HST) nickel-hydrogen battery module was designed by Lockheed Missile & Space Co (LMSC) and manufactured by Eagle-Picher Ind. (EPI) for the Marshall Space Flight Center (MSFC) as an Orbital Replacement Unit (ORU) for the nickel-cadmium batteries originally selected for this low earth orbit mission. The design features of the HST nickel hydrogen battery are described and the results of an extended charge retention test are summarized.

  5. Electrochemical characterization of Fe-air rechargeable oxide battery in planar solid oxide cell stacks

    NASA Astrophysics Data System (ADS)

    Fang, Qingping; Berger, Cornelius M.; Menzler, Norbert H.; Bram, Martin; Blum, Ludger

    2016-12-01

    Iron-air rechargeable oxide batteries (ROB) comprising solid oxide cells (SOC) as energy converters and Fe/metal-oxide redox couples were characterized using planar SOC stacks. The charge and discharge of the battery correspond to the operations in the electrolysis and fuel cell modes, respectively, but with a stagnant atmosphere consisting of hydrogen and steam. A novel method was employed to establish the stagnant atmosphere for battery testing during normal SOC operation without complicated modification to the test bench and stack/battery concept. Manipulation of the gas compositions during battery operation was not necessary, but the influence of the leakage current from the testing system had to be considered. Batteries incorporating Fe2O3/8YSZ, Fe2O3/CaO and Fe2O3/ZrO2 storage materials were characterized at 800 °C. A maximum charge capacity of 30.4 Ah per layer (with an 80 cm2 active cell area) with ∼0.5 mol Fe was reached with a current of 12 A. The charge capacity lost 11% after ∼130 ROB cycles due to the increased agglomeration of active materials and formation of a dense oxide layer on the surface. The round trip efficiencies of the tested batteries were ≤84% due to the large internal resistance. With state-of-the-art cells, the round trip efficiency can be further improved.

  6. Crossing the North Sea seems to make DCD disappear: cross-validation of Movement Assessment Battery for Children-2 norms.

    PubMed

    Niemeijer, Anuschka S; van Waelvelde, Hilde; Smits-Engelsman, Bouwien C M

    2015-02-01

    The Movement Assessment Battery for Children has been revised as the Movement ABC-2 (Henderson, Sugden, & Barnett, 2007). In Europe, the 15th percentile score on this test is recommended for one of the DSM-IV diagnostic criteria for Developmental Coordination Disorder (DCD). A representative sample of Dutch and Flemish children was tested to cross-validate the UK standard scores, including the 15th percentile score. First, the mean, SD and percentile scores of Dutch children were compared to those of UK normative samples. Item standard scores of Dutch speaking children deviated from the UK reference values suggesting necessary adjustments. Except for very young children, the Dutch-speaking samples performed better. Second, based on the mean and SD and clinical relevant cut-off scores (5th and 15th percentile), norms were adjusted for the Dutch population. For diagnostic use, researchers and clinicians should use the reference norms that are valid for the group of children they are testing. The results indicate that there possibly is an effect of testing procedure in other countries that validated the UK norms and/or cultural influence on the age norms of the Movement ABC-2. It is suggested to formulate criterion-based norms for age groups in addition to statistical norms. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Evaluation program for secondary spacecraft cells

    NASA Technical Reports Server (NTRS)

    Christy, D. E.; Harkness, J. D.

    1973-01-01

    A life cycle test of secondary electric batteries for spacecraft applications was conducted. A sample number of nickel cadmium batteries were subjected to general performance tests to determine the limit of their actual capabilities. Weaknesses discovered in cell design are reported and aid in research and development efforts toward improving the reliability of spacecraft batteries. A statistical analysis of the life cycle prediction and cause of failure versus test conditions is provided.

  8. Optimum selection of an implantable secondary battery for an artificial heart by examination of the cycle life test.

    PubMed

    Okamoto, Eiji; Watanabe, Kazuya; Hashiba, Kunihiro; Inoue, Taku; Iwazawa, Eichi; Momoi, Masato; Hashimoto, Takuya; Mitamura, Yoshinori

    2002-01-01

    An implantable secondary battery is one of the key components in a total artificial heart system. Because a 2 year cycle life is required, the cycle life of the secondary battery as well as its charge and discharge properties are important parameters for selection of an appropriate battery. We carried out cycle life tests on four kinds of rechargeable batteries (a Ni-MH secondary battery, a Ni-Cd secondary battery, a Li-ion battery with a graphite anode, and a Li-ion battery with a nongraphitizable carbon electrode) to determine their suitability as implanted back-up batteries. Each of the batteries was charge/discharge cycled at 37 degrees C to 39 degrees C using a charge current of 1 C ampere, and they were each fully discharged under either pulsatile discharge loads, which mimicked pulsatile operation, or a nonpulsatile load equivalent to the average of the pulsatile loads. The two Li-ion batteries made by different manufacturers both met the minimum requirement of cycle life of more than 1,500 cycles, considering safety coefficient regardless of the discharge pattern. In addition, the temperature increase of these Li-ion batteries (3 degrees C) was lower than that of Ni-Cd and Ni-MH batteries (15-25 degrees C). Out of these four batteries, the two Li-ion batteries are the most suitable for use in a totally implantable artificial heart system.

  9. Genetic Influences on Cognitive Function Using the Cambridge Neuropsychological Test Automated Battery

    ERIC Educational Resources Information Center

    Singer, Jamie J.; MacGregor, Alex J.; Cherkas, Lynn F.; Spector, Tim D.

    2006-01-01

    The genetic relationship between intelligence and components of cognition remains controversial. Conflicting results may be a function of the limited number of methods used in experimental evaluation. The current study is the first to use CANTAB (The Cambridge Neuropsychological Test Automated Battery). This is a battery of validated computerised…

  10. The characteristics and limitations of the MPS/MMS battery charging system

    NASA Technical Reports Server (NTRS)

    Ford, F. E.; Palandati, C. F.; Davis, J. F.; Tasevoli, C. M.

    1980-01-01

    A series of tests was conducted on two 12 ampere hour nickel cadmium batteries under a simulated cycle regime using the multiple voltage versus temperature levels designed into the modular power system (MPS). These tests included: battery recharge as a function of voltage control level; temperature imbalance between two parallel batteries; a shorted or partially shorted cell in one of the two parallel batteries; impedance imbalance of one of the parallel battery circuits; and disabling and enabling one of the batteries from the bus at various charge and discharge states. The results demonstrate that the eight commandable voltage versus temperature levels designed into the MPS provide a very flexible system that not only can accommodate a wide range of normal power system operation, but also provides a high degree of flexibility in responding to abnormal operating conditions.

  11. Characterization testing of a 40 AHR bipolar nickel-hydrogen battery

    NASA Astrophysics Data System (ADS)

    Brewer, Jeffrey C.; Manzo, Michelle A.; Gemeiner, Russel P.

    1989-12-01

    Extensive characterization testing has been done on a second 40 amp-hour (Ahr), 10-cell bipolar nickel-hydrogen (Ni-H2) battery to study the effects of such operating parameters as charge and discharge rates, temperature, and pressure, on capacity, Ahr and watt-hour (Whr) efficiencies, end-of-charge (EOC) and mid-point discharge voltages. Testing to date has produced many interesting results, with the battery performing well throughout all of the test matrix except during the high-rate (5C and 10C) discharges, where poorer than expected results were observed. The exact cause of this poor performance is, as yet, unknown. Small scale 2 x 2 inch battery tests are to be used in studying this problem. Low earth orbit (LEO) cycle life testing at a 40 percent depth of discharge (DOD) and 10 C is scheduled to follow the characterization testing.

  12. Does the Cambridge Automated Neuropsychological Test Battery (CANTAB) Distinguish Between Cognitive Domains in Healthy Older Adults?

    PubMed

    Lenehan, Megan E; Summers, Mathew J; Saunders, Nichole L; Summers, Jeffery J; Vickers, James C

    2016-04-01

    The Cambridge Neuropsychological Test Automated Battery (CANTAB) is a semiautomated computer interface for assessing cognitive function. We examined whether CANTAB tests measured specific cognitive functions, using established neuropsychological tests as a reference point. A sample of 500 healthy older (M = 60.28 years, SD = 6.75) participants in the Tasmanian Healthy Brain Project completed battery of CANTAB subtests and standard paper-based neuropsychological tests. Confirmatory factor analysis identified four factors: processing speed, verbal ability, episodic memory, and working memory. However, CANTAB tests did not consistently load onto the cognitive domain factors derived from traditional measures of the same function. These results indicate that five of the six CANTAB subtests examined did not load onto single cognitive functions. These CANTAB tests may lack the sensitivity to measure discrete cognitive functions in healthy populations or may measure other cognitive domains not included in the traditional neuropsychological battery. © The Author(s) 2015.

  13. Characterization testing of a 40 AHR bipolar nickel-hydrogen battery

    NASA Technical Reports Server (NTRS)

    Brewer, Jeffrey C.; Manzo, Michelle A.; Gemeiner, Russel P.

    1989-01-01

    Extensive characterization testing has been done on a second 40 amp-hour (Ahr), 10-cell bipolar nickel-hydrogen (Ni-H2) battery to study the effects of such operating parameters as charge and discharge rates, temperature, and pressure, on capacity, Ahr and watt-hour (Whr) efficiencies, end-of-charge (EOC) and mid-point discharge voltages. Testing to date has produced many interesting results, with the battery performing well throughout all of the test matrix except during the high-rate (5C and 10C) discharges, where poorer than expected results were observed. The exact cause of this poor performance is, as yet, unknown. Small scale 2 x 2 inch battery tests are to be used in studying this problem. Low earth orbit (LEO) cycle life testing at a 40 percent depth of discharge (DOD) and 10 C is scheduled to follow the characterization testing.

  14. Characterization testing of a 40 ampere hour bipolar nickel-hydrogen battery

    NASA Technical Reports Server (NTRS)

    Brewer, Jeffrey C.; Manzo, Michelle A.; Gemeiner, Russel P.

    1990-01-01

    Extensive characterization testing has been done on a second 40-ampere hour (A h), 10-cell, bipolar nickel-hydrogen (Ni-H2) battery, to study the effects of operating parameters such as charge and discharge rates, temperature, and pressure on capacity, A h and watt hour (W h) efficiencies, and end-of-charge and midpoint discharge voltages. Testing to date has produced many interesting results, with the battery performing well throughout the test matrix except during the high-rate (5 C and 10 C) discharges, where poorer than expected results were observed. The exact cause of this poor performance is, as yet, unknown. Small scale 2 in. x 2 in. battery tests are to be used in studying this problem. Low earth orbit cycle life testing at a 40-percent depth of discharge and 10 C is scheduled to follow the characterization testing.

  15. A degradation-based sorting method for lithium-ion battery reuse.

    PubMed

    Chen, Hao; Shen, Julia

    2017-01-01

    In a world where millions of people are dependent on batteries to provide them with convenient and portable energy, battery recycling is of the utmost importance. In this paper, we developed a new method to sort 18650 Lithium-ion batteries in large quantities and in real time for harvesting used cells with enough capacity for battery reuse. Internal resistance and capacity tests were conducted as a basis for comparison with a novel degradation-based method based on X-ray radiographic scanning and digital image contrast computation. The test results indicate that the sorting accuracy of the test cells is about 79% and the execution time of our algorithm is at a level of 200 milliseconds, making our method a potential real-time solution for reusing the remaining capacity in good used cells.

  16. Development of a menu of performance tests self-administered on a portable microcomputer

    NASA Technical Reports Server (NTRS)

    Wilkes, Robert L.; Kuntz, Lois-Ann; Kennedy, Robert S.

    1987-01-01

    Eighteen cognitive, motor, and information processing performance subtests were screened for self-administration over 10 trials by 16 subjects. When altered presentation forms of the same test were collectively considered, the battery composition was reduced to 10 distinctly different measures. A fully automated microbased testing system was employed in presenting the battery of subtests. Successful self-administration of the battery provided for the field testing of the automated system and facilitated convenient data collection. Total test administration time was 47.2 minutes for each session. Results indicated that nine of the tests stabilized, but for a short battery of tests only five are recommended for use in repeated-measures research. The five recommended tests include: the Tapping series, Number Comparison, Short-term Memory, Grammatical Reasoning, and 4-Choice Reaction Time. These tests can be expected to reveal three factors: (1) cognition, (2) processing quickness, and (3) motor. All the tests stabilized in 24 minutes, or approximately two 12-minute sessions.

  17. Research, development, and demonstration of lead-acid batteries for electric-vehicle propulsion. Annual report, 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-03-01

    The first development effort in improving lead-acid batteries fore electric vehicles was the improvement of electric vehicle batteries using flat pasted positive plates and the second was for a tubular long life positive plate. The investigation of 32 component variables based on a flat pasted positive plate configuration is described. The experiment tested 96 - six volt batteries for characterization at 0, 25, and 40/sup 0/C and for cycle life capability at the 3 hour discharge rate with a one cycle, to 80% DOD, per day regime. Four positive paste formulations were selected. Two commercially available microporous separators were usedmore » in conjunction with a layer of 0.076 mm thick glass mat. Two concentrations of battery grade sulfuric acid were included in the test to determine if an increase in concentration would improve the battery capacity sufficient to offset the added weight of the more concentrated solution. Two construction variations, 23 plate elements with outside negative plates and 23 plate elements with outside positive plates, were included. The second development effort was an experiment designed to study the relationship of 32 component variables based on a tubular positive plate configuration. 96-six volt batteries were tested at various discharge rates at 0, 25, and 40/sup 0/C along with cycle life testing at 80% DOD of the 3 hour rate. 75 batteries remain on cycle life testing with 17 batteries having in excess of 365 life cycles. Preliminary conclusions indicate: the tubular positive plate is far more capable of withstanding deep cycles than is the flat pasted plate; as presently designed 40 Whr/kg can not be achieved, since 37.7 Whr/kg was the best tubular data obtained; electrolyte circulation is impaired due to the tight element fit in the container; and a redesign is required to reduce the battery weight which will improve the Whr/kg value. This redesign is complete and new molds have been ordered.« less

  18. Nickel-hydrogen battery state of charge during low rate trickle charging

    NASA Technical Reports Server (NTRS)

    Lurie, C.; Foroozan, S.; Brewer, J.; Jackson, L.

    1995-01-01

    Battery temperature increase, due to low rate trickle charging, has been determined experimentally, using a six cell battery module in a test setup simulating the anticipated AXAF-1 prelaunch environment. Test results indicate trickle charge rates less than or equal to the self discharge rate do not increase dissipation beyond that due to the self discharge. Significant trickle charge rates (approximately C/500) result in battery temperatures only a few degrees (F) higher than those observed during periods of open circuit stand.

  19. Synthetic battery cycling

    NASA Technical Reports Server (NTRS)

    Thaller, L. H.

    1981-01-01

    The use of interactive computer graphics is suggested as an aid in battery system development. Mathematical representations of simplistic but fully representative functions of many electrochemical concepts of current practical interest will permit battery level charge and discharge phenomena to be analyzed in a qualitative manner prior to the assembly and testing of actual hardware. This technique is a useful addition to the variety of tools available to the battery system designer as he bridges the gap between interesting single cell life test data and reliable energy storage subsystems.

  20. Battery model for electrical power system energy balance

    NASA Technical Reports Server (NTRS)

    Hafen, D. P.

    1983-01-01

    A model to simulate nickel-cadmium battery performance and response in a spacecraft electrical power system energy balance calculation was developed. The voltage of the battery is given as a function of temperature, operating depth-of-charge (DOD), and battery state-of-charge. Also accounted for is charge inefficiency. A battery is modeled by analysis of the results of a multiparameter battery cycling test at various temperatures and DOD's.

  1. Development of a Long-Range Underwater Vehicle

    DTIC Science & Technology

    2014-09-30

    lithium- seawater batteries . Specific objectives are (1) to test in the laboratory and ocean new lithium- seawater batteries developed and manufactured...by the PolyPlus Battery Company, (2) to discover how to mount and operate these cells to maximize their mass transfer with the ambient seawater and to...respectively. The achievable energy density for batteries is much less. PolyPlus Battery Company has developed a lithium- seawater battery (http

  2. Study of oxygen gas production phenomenon during stand and discharge in silver-zinc batteries

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Standard production procedures for manufacturing silver zinc batteries are evaluated and modified to reduce oxygen generation during open circuit stand and discharge. Production predictions of several variable combinations using analysis models are listed for minimum gassing, with emphasis on the concentration of potassium hydroxide in plate formation. A recommendation for work optimizing the variables involved in plate processing is included.

  3. A Step-by-Step Design Methodology for a Base Case Vanadium Redox-Flow Battery

    ERIC Educational Resources Information Center

    Moore, Mark; Counce, Robert M.; Watson, Jack S.; Zawodzinski, Thomas A.; Kamath, Haresh

    2012-01-01

    The purpose of this work is to develop an evolutionary procedure to be used by Chemical Engineering students for the base-case design of a Vanadium Redox-Flow Battery. The design methodology is based on the work of Douglas (1985) and provides a profitability analysis at each decision level so that more profitable alternatives and directions can be…

  4. Experiences with the in vivo and in vitro comet assay in regulatory testing.

    PubMed

    Frötschl, Roland

    2015-01-01

    The in vivo comet assay has recently been implemented into regulatory genotoxicity testing of pharmaceuticals with inclusion into the ICH S2R1 guidance. Regulatory genotoxicity testing aims to detect DNA alterations in form of gene mutations, larger scale chromosomal damage and recombination and aneuploidy. The ICH S2R1 guideline offers two options of standard batteries of tests for the detection of these endpoints. Both options start with an AMES assay and option 1 includes an in vitro mammalian cell assay and an in vivo micronucleus assay in rodent, whereas option 2 includes an in vivo micronucleus assay in bone marrow in rodent and a second in vivo assay in a second tissue with a second endpoint. The test recommended as second in vivo test is the comet assay in rat liver. The in vivo comet assay is considered as mature enough to ensure reliable detection of relevant in vivo genotoxicants in combination with the micronucleus test in bone marrow and the AMES assay. Although lots of research papers have been published using the in vitro comet assay, the in vitro version has not been implemented into official regulatory testing guidelines. A survey of the years 1999-2014 revealed 27 in vivo comet assays submitted to BfArM with market authorisation procedures, European and national advice procedures and clinical trial applications. In three procedures, in vitro comet assays had been submitted within the genetic toxicology packages. © The Author 2014. Published by Oxford University Press on behalf of the Mutagenesis Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  5. The 1973 GSFC battery workshop, second day. [technology transfer

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Technological progress in the development, testing, and manufacturing of nickel-cadmium battery cells as well as hydrogen cells is presented. The following major topics were discussed: (1) carbonate analysis; (2) nickel-cadmium memory effect; (3) use of batteries in an automatic acquisition and control system; (4) accelerated testing; (5) formulation of a mathematical odel for a nickel-cadmium cell; (6) development of a light weight nickel-cadmium battery capable of delivering 20 watt hours per pound; (7) magnetic testing of nickel-cadmium cells; (8) design and performance characteristics of nickel-hydrogen and silver-hydrogen cells; and (9) development of a semiprismatic cell design. For Vol. 1, see N75-15152.

  6. Differential Predictive Validity of a Preschool Battery Across Race and Sex.

    ERIC Educational Resources Information Center

    Reynolds, Cecil R.

    Determination of the fairness of preschool tests for use with children of varying cultural backgrounds is the major objective of this study. The predictive validity of a battery of preschool tests, chosen to represent the core areas of preschool assessment, across race and sex, was evaluated. Validity of the battery was examined over a 12-month…

  7. 49 CFR 175.10 - Exceptions for passengers, crewmembers, and air operators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... mobility aid equipped with a lithium ion battery, when carried as checked baggage, provided— (i) The lithium ion battery must be of a type that successfully passed each test in the UN Manual of Tests and... the movement of baggage, mail, service items, or other cargo; (v) Where a lithium ion battery-powered...

  8. 49 CFR 175.10 - Exceptions for passengers, crewmembers, and air operators.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... mobility aid equipped with a lithium ion battery, when carried as checked baggage, provided— (i) The lithium ion battery must be of a type that successfully passed each test in the UN Manual of Tests and... the movement of baggage, mail, service items, or other cargo; (v) Where a lithium ion battery-powered...

  9. Effect of (4a) a novel 5-HT3 receptor antagonist on chronic unpredictable mild stress induced depressive-like behavior in mice: an approach using behavioral tests battery.

    PubMed

    Kurhe, Yeshwant; Mahesh, Radhakrishnan; Gupta, Deepali; Thangaraj, Devadoss

    2015-01-01

    The inconsistent therapeutic outcome necessitates designing and identifying novel therapeutic interventions for depression. Hence, the present study deals with the investigation of antidepressant-like effects of a novel 5-HT3 receptor antagonist (4-phenylpiperazin-1-yl) (quinoxalin-2-yl) methanone (4a) on chronic unpredictable mild stress (CUMS) induced behavioral and biochemical alterations. Animals were subjected to different stressors for a period of 28 days. On day 15 after the subsequent stress procedure, mice were administered with (4a) (2 and 4 mg/kg p.o.), escitalopram (10 mg/kg p.o.), or vehicle (10 mL/kg p.o.) until day 28 along with the CUMS. Thereafter, behavioral battery tests like locomotor score, sucrose preference test, forced swim test (FST), tail suspension test (TST), and elevated plus maze (EPM) were performed. Biochemical assays like lipid peroxidation, nitrite levels, reduced glutathione (GSH), catalase, and superoxide dismutase (SOD) were estimated in the mice brain homogenate. (4a) Dose dependently attenuated the behavioral alterations by increasing the sucrose consumption, reducing the immobility time in FST and TST, increasing the open arm number of entries and time in EPM. Furthermore, biochemical alterations were reversed by (4a) as examined by reduced lipid peroxidation and nitrite levels and elevated antioxidant enzyme levels like GSH, catalase and SOD. (4a) exhibits antidepressant potential by reversing the CUMS induced behavioral and biochemical changes in mice.

  10. Testing the tests--an empirical evaluation of screening tests for the detection of cognitive impairment in aviators.

    PubMed

    Stokes, A F; Banich, M T; Elledge, V C

    1991-08-01

    The FAA has expressed concern that flight safety could be compromised by undetected cognitive impairment in pilots due to conditions such as substance abuse, mental illness, and neuropsychological problems. Interest has been shown in the possibility of adding a brief "mini-mental exam," or a simple automated test-battery to the standard flight medical to screen for such conditions. The research reported here involved the empirical evaluation of two "mini-mental exams," two paper-and-pencil test batteries, and a prototype version of an automated screening battery. Sensitivity, specificity, and positive predictive value were calculated for each sub-task in a discriminant study of 54 pilots and 62 individuals from a heterogeneous clinical population. Results suggest that the "mini-mental exams" are poor candidates for a screening test. The automated battery showed the best discrimination performance, in part because of the incorporation of dual-task tests of divided attention performance. These tests appear to be particularly sensitive to otherwise difficult-to-detect cognitive impairments of a mild or subtle nature. The use of an automated battery of tests as a screening instrument does appear to be feasible in principle, but the practical success of a screening program is heavily dependent upon the actual prevalence of cognitive impairment in the medical applicant population.

  11. Initial validation of a web-based self-administered neuropsychological test battery for older adults and seniors.

    PubMed

    Hansen, Tor Ivar; Haferstrom, Elise Christina D; Brunner, Jan F; Lehn, Hanne; Håberg, Asta Kristine

    2015-01-01

    Computerized neuropsychological tests are effective in assessing different cognitive domains, but are often limited by the need of proprietary hardware and technical staff. Web-based tests can be more accessible and flexible. We aimed to investigate validity, effects of computer familiarity, education, and age, and the feasibility of a new web-based self-administered neuropsychological test battery (Memoro) in older adults and seniors. A total of 62 (37 female) participants (mean age 60.7 years) completed the Memoro web-based neuropsychological test battery and a traditional battery composed of similar tests intended to measure the same cognitive constructs. Participants were assessed on computer familiarity and how they experienced the two batteries. To properly test the factor structure of Memoro, an additional factor analysis in 218 individuals from the HUNT population was performed. Comparing Memoro to traditional tests, we observed good concurrent validity (r = .49-.63). The performance on the traditional and Memoro test battery was consistent, but differences in raw scores were observed with higher scores on verbal memory and lower in spatial memory in Memoro. Factor analysis indicated two factors: verbal and spatial memory. There were no correlations between test performance and computer familiarity after adjustment for age or age and education. Subjects reported that they preferred web-based testing as it allowed them to set their own pace, and they did not feel scrutinized by an administrator. Memoro showed good concurrent validity compared to neuropsychological tests measuring similar cognitive constructs. Based on the current results, Memoro appears to be a tool that can be used to assess cognitive function in older and senior adults. Further work is necessary to ascertain its validity and reliability.

  12. Initial validation of a web-based self-administered neuropsychological test battery for older adults and seniors

    PubMed Central

    Hansen, Tor Ivar; Haferstrom, Elise Christina D.; Brunner, Jan F.; Lehn, Hanne; Håberg, Asta Kristine

    2015-01-01

    Introduction: Computerized neuropsychological tests are effective in assessing different cognitive domains, but are often limited by the need of proprietary hardware and technical staff. Web-based tests can be more accessible and flexible. We aimed to investigate validity, effects of computer familiarity, education, and age, and the feasibility of a new web-based self-administered neuropsychological test battery (Memoro) in older adults and seniors. Method: A total of 62 (37 female) participants (mean age 60.7 years) completed the Memoro web-based neuropsychological test battery and a traditional battery composed of similar tests intended to measure the same cognitive constructs. Participants were assessed on computer familiarity and how they experienced the two batteries. To properly test the factor structure of Memoro, an additional factor analysis in 218 individuals from the HUNT population was performed. Results: Comparing Memoro to traditional tests, we observed good concurrent validity (r = .49–.63). The performance on the traditional and Memoro test battery was consistent, but differences in raw scores were observed with higher scores on verbal memory and lower in spatial memory in Memoro. Factor analysis indicated two factors: verbal and spatial memory. There were no correlations between test performance and computer familiarity after adjustment for age or age and education. Subjects reported that they preferred web-based testing as it allowed them to set their own pace, and they did not feel scrutinized by an administrator. Conclusions: Memoro showed good concurrent validity compared to neuropsychological tests measuring similar cognitive constructs. Based on the current results, Memoro appears to be a tool that can be used to assess cognitive function in older and senior adults. Further work is necessary to ascertain its validity and reliability. PMID:26009791

  13. Hubble Space Telescope 2004 Battery Update

    NASA Technical Reports Server (NTRS)

    Hollandsworth, Roger; Armantrout, Jon; Rao, Gopalakrishna M.

    2004-01-01

    Battery cell wear out mechanisms and signatures are examined and compared to orbital data from the six on-orbit Hubble Space Telescope (HST) batteries, and the Flight Spare Battery (FSB) Test Bed at Marshall Space Fiight Center (MSFC), which is instrumented with individual cell voltage monitoring.

  14. Reliability Through Life of Internal Protection Devices in Small-Cell ABSL Batteries

    NASA Technical Reports Server (NTRS)

    Neubauer, Jeremy; Ng, Ka Lok; Bennetti, Andrea; Pearson, Chris; Rao, gopal

    2007-01-01

    This viewgraph presentation reviews a reliability analysis of small cell protection batteries. The contents include: 1) The s-p Topology; 2) Cell Level Protection Devices; 3) Battery Level Fault Protection; 4) Large Cell Comparison; and 5) Battery Level Testing and Results.

  15. Position requirements for space station personnel and linkages to portable microcomputer performance assessment

    NASA Technical Reports Server (NTRS)

    Jeanneret, P. R.

    1988-01-01

    The development and use of a menu of performance tests that can be self-administered on a portable microcomputer are investigated. In order to identify, develop, or otherwise select the relevant human capabilities/attributes to measure and hence include in the performance battery, it is essential that an analysis be conducted of the jobs or functions that will be performed throughout a space shuttle mission. The primary job analysis instrument, the Position Analysis Questionnaire (PAQ), is discussed in detail so the reader will have sufficient background for understanding the application of the instrument to the various work activities included within the scope of the study, and the derivation of the human requirements (abilities/attributes) from the PAQ analyses. The research methodology is described and includes the procedures used for gathering the PAQ data. The results are presented in detail with specific emphasis on identifying critical requirements that can be measured with a portable computerized assessment battery. A discussion of the results is given with implications for future research.

  16. A comparative study of commercial lithium ion battery cycle life in electric vehicle: Capacity loss estimation

    NASA Astrophysics Data System (ADS)

    Han, Xuebing; Ouyang, Minggao; Lu, Languang; Li, Jianqiu

    2014-12-01

    Now the lithium ion batteries are widely used in electric vehicles (EV). The cycle life is among the most important characteristics of the power battery in EV. In this report, the battery cycle life experiment is designed according to the actual working condition in EV. Five different commercial lithium ion cells are cycled alternatively under 45 °C and 5 °C and the test results are compared. Based on the cycle life experiment results and the identified battery aging mechanism, the battery cycle life models are built and fitted by the genetic algorithm. The capacity loss follows a power law relation with the cycle times and an Arrhenius law relation with the temperature. For automotive application, to save the cost and the testing time, a battery SOH (state of health) estimation method combined the on-line model based capacity estimation and regular calibration is proposed.

  17. Study of imbalanced internal resistance on drop voltage of LiFePO4 battery system connected in parallel

    NASA Astrophysics Data System (ADS)

    Adie Perdana, Fengky; Supriyanto, Agus; Purwanto, Agus; Jamaluddin, Anif

    2017-01-01

    The purpose of this research focuses on the effect of imbalanced internal resistance for the drop voltage of LiFePO4 18650 battery system connected in parallel. The battery pack has been assembled consist of two cell battery LiFePO4 18650 that has difference combination of internal resistance. Battery pack was tested with 1/C constant current charging, 3,65V per group sel, 3,65V constant voltage charging, 5 minutes of rest time between charge and discharge process, 1/2C Constant current discharge until 2,2V, 26 cycle of measurement test, and 4320 minutes rest time after the last charge cycle. We can conclude that the difference combination of internal resistance on the battery pack seriously influence the drop voltage of a battery. Theoretical and experimental result show that the imbalance of internal resistance during cycling are mainly responsible for the drop voltage of LiFePO4 parallel batteries. It is thus a good way to avoid drop voltage fade of parallel battery system by suppressing variations of internal resistance.

  18. Comparison Between a Self-Administered and Supervised Version of a Web-Based Cognitive Test Battery: Results From the NutriNet-Santé Cohort Study

    PubMed Central

    Bailet, Marion; Lecoffre, Amandine C; Galan, Pilar; Hercberg, Serge; Amieva, Hélène; Kesse-Guyot, Emmanuelle

    2016-01-01

    Background Dementia is a major public health problem, and repeated cognitive data from large epidemiological studies could help to develop efficient measures of early prevention. Data collection by self-administered online tools could drastically reduce the logistical and financial burden of such large-scale investigations. In this context, it is important to obtain data concerning the comparability of such new online tools with traditional, supervised modes of cognitive assessment. Objective Our objective was to compare self-administration of the Web-based NutriNet-Santé cognitive test battery (NutriCog) with administration by a neuropsychologist. Methods The test battery included four tests, measuring, among others aspects, psychomotor speed, attention, executive function, episodic memory, working memory, and associative memory. Both versions of the cognitive battery were completed by 189 volunteers (either self-administered version first, n=99, or supervised version first, n=90). Subjects also completed a satisfaction questionnaire. Concordance was assessed by Spearman correlation. Results Agreement between both versions varied according to the investigated cognitive task and outcome variable. Spearman correlations ranged between .42 and .73. Moreover, a majority of participants responded that they “absolutely” or “rather” agreed that the duration of the self-administered battery was acceptable (184/185, 99.5%), that the tasks were amusing (162/185, 87.6%), that the instructions were sufficiently detailed (168/185; 90.8%) and understandable (164/185, 88.7%), and that they had overall enjoyed the test battery (182/185, 98.4%). Conclusions The self-administered version of the Web-based NutriCog cognitive test battery provided similar information as the supervised version. Thus, integrating repeated cognitive evaluations into large cohorts via the implementation of self-administered online versions of traditional test batteries appears to be feasible. PMID:27049114

  19. A degradation-based sorting method for lithium-ion battery reuse

    PubMed Central

    Chen, Hao

    2017-01-01

    In a world where millions of people are dependent on batteries to provide them with convenient and portable energy, battery recycling is of the utmost importance. In this paper, we developed a new method to sort 18650 Lithium-ion batteries in large quantities and in real time for harvesting used cells with enough capacity for battery reuse. Internal resistance and capacity tests were conducted as a basis for comparison with a novel degradation-based method based on X-ray radiographic scanning and digital image contrast computation. The test results indicate that the sorting accuracy of the test cells is about 79% and the execution time of our algorithm is at a level of 200 milliseconds, making our method a potential real-time solution for reusing the remaining capacity in good used cells. PMID:29023485

  20. Design and Field Test of a WSN Platform Prototype for Long-Term Environmental Monitoring

    PubMed Central

    Lazarescu, Mihai T.

    2015-01-01

    Long-term wildfire monitoring using distributed in situ temperature sensors is an accurate, yet demanding environmental monitoring application, which requires long-life, low-maintenance, low-cost sensors and a simple, fast, error-proof deployment procedure. We present in this paper the most important design considerations and optimizations of all elements of a low-cost WSN platform prototype for long-term, low-maintenance pervasive wildfire monitoring, its preparation for a nearly three-month field test, the analysis of the causes of failure during the test and the lessons learned for platform improvement. The main components of the total cost of the platform (nodes, deployment and maintenance) are carefully analyzed and optimized for this application. The gateways are designed to operate with resources that are generally used for sensor nodes, while the requirements and cost of the sensor nodes are significantly lower. We define and test in simulation and in the field experiment a simple, but effective communication protocol for this application. It helps to lower the cost of the nodes and field deployment procedure, while extending the theoretical lifetime of the sensor nodes to over 16 years on a single 1 Ah lithium battery. PMID:25912349

  1. Diagnosing mild cognitive impairment in Parkinson's disease: which tests perform best in the Italian population?

    PubMed

    Federico, Angela; Trentin, Michela; Zanette, Giampietro; Mapelli, Daniela; Picelli, Alessandro; Smania, Nicola; Tinazzi, Michele; Tamburin, Stefano

    2017-08-01

    Mild cognitive impairment (MCI) is common in patients with Parkinson's disease (PD) and should be recognized early because it represents a predictor of PD-related dementia and worse disease course. Diagnostic criteria for PD-related MCI (PD-MCI) have recently been defined by a Movement Disorders Society (MDS) task force. The present study explored which neuropsychological tests perform best for a level II (i.e., comprehensive neuropsychological assessment) diagnosis of PD-MCI according to the MDS task force criteria in Italian-speaking PD patients. To this aim, we assessed a comprehensive 23-item neuropsychological battery, derived the best-performing 10-test battery (i.e., two tests per domain for each of the five cognitive domains), and explored its accuracy for diagnosing PD-MCI in comparison to the full battery in a group of PD patients. A secondary aim was to explore the role of this battery for subtyping PD-MCI according to single-domain vs. multiple-domain involvement. The 10-test battery showed 73% sensitivity and 100% specificity for diagnosing PD-MCI, and 69% sensitivity and 100% specificity for PD-MCI subtyping. In patients older than 70 years, we derived a slightly different 10-test battery with 84% sensitivity and 100% specificity for PD-MCI diagnosis, and 86% sensitivity and 100% specificity for PD-MCI subtyping. These 10-item neuropsychological batteries might represent a good trade-off between diagnostic accuracy and time of application, and their role in PD-MCI diagnosis and subtyping should be further explored in future prospective studies.

  2. Validation of Battery Safety for Space Missions

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith

    2012-01-01

    Presentation covers: (1) Safety Certification Process at NASA (2) Safety Testing for Lithium-ion Batteries (3) Limitations Observed with Li-ion Batteries in High Voltage and High Capacity Configurations.

  3. Hubble Space Telescope: Battery Capacity Trend Studies

    NASA Technical Reports Server (NTRS)

    Rao, M. Gopalakrishna; Hollandsworth, Roger; Armantrout, Jon

    2004-01-01

    Battery cell wear out mechanisms and signatures are examined and compared to orbital data from the six on-orbit Hubble Space Telescope (HST) batteries, and the Flight Spare Battery (FSB) Test Bed at Marshall Space Flight Center (MSFC), which is instrumented with individual cell voltage monitoring. Capacity trend data is presented which suggests HST battery replacement is required in 2005-2007 or sooner.

  4. Performance and Safety Characteristics of Sanyo NiCd Cells

    NASA Technical Reports Server (NTRS)

    Deng, Yi; Jeevarajan, Judith; Bragg, Bobby; Zhang, Wenlin

    2002-01-01

    NiCd batteries are widely used for high drain applications like power tools and also in other portable equipment like cameras, PCs, etc. NASA and Dreamtime Holdings, Inc. worked together to have the capability of a High Definition TV (HDTV) on the ISS and Space Shuttle. The Sanyo HD camcorder was used on the STS 105 fight in July, 2001 . The camcorder used two versions of a NiCd battery. One was a cOlnmercial off-the-shelf Sony BP90 battery pack that had Sanyo NiCd D cells. The other was a modified battery (FBP-90) made by Frezzi Energy, which also had the same Sanyo NiCd D cells. The battery has 10 NiCd D cells in series to form a 12 V pack with 5.0 Ah capacity. Our current study involved the perforn1ance and abuse tests on the Sanyo NiCd 5.0 Ah D cells. The best combination of charge/discharge current rate is 0.3C for charge and 1/2e for discharge within 200 cycles. No significant changes in capacity were observed in 200 cycles. The cell also showed capability of 5C (25.0A) high rate discharge. In overcharge and overdischarge tests, all tested cells passed the tests without venting. In imbalance tests, the battery pack could be charged and discharged only at relatively low current. At charge current of 1.0A or less, the imbalanced cells in the battery pack displayed relatively high temperatures during charge or discharge. The cells functioned normally during internal short and no mishap occurred during external short. Cells passed exposure tests at 80 C and no leakage till 150 C during heat-tovent tests.

  5. Factor structure of the Halstead-Reitan Neuropsychological Battery for children: a brief report supplement.

    PubMed

    Ross, Sylvia An; Allen, Daniel N; Goldstein, Gerald

    2014-01-01

    The Halstead-Reitan Neuropsychological Battery (HRNB) is the first factor-analyzed neuropsychological battery and consists of three batteries for young children, older children, and adults. Halstead's original factor analysis extracted four factors from the adult version of the battery, which were the basis for his theory of biological intelligence. These factors were called Central Integrative Field, Abstraction, Power, and Directional. Since this original analysis, Reitan's additions to the battery, and the development of the child versions of the test, this factor-analytic research continued. An introduction and the adult literature are reviewed in Ross, Allen, and Goldstein ( in press ). In this supplemental article, factor-analytic studies of the HRNB with children are reviewed. It is concluded that factor analysis of the HRNB or Reitan-Indiana Neuropsychological Battery with children does not replicate the extensiveness of the adult literature, although there is some evidence that when the traditional battery for older children is used, the factor structure is similar to what is found in adult studies. Reitan's changes to the battery appear to have added factors including language and sensory-perceptual factors. When other tests and scoring methods are used in addition to the core battery, differing solutions are produced.

  6. Key results of battery performance and life tests at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1991-12-01

    Advanced battery technology evaluations are performed under simulated electric vehicle operating conditions at Argonne National Laboratory's & Diagnostic Laboratory (ADL). The ADL provide a common basis for both performance characterization and life evaluation with unbiased application of tests and analyses. This paper summarizes the performance characterizations and life evaluations conducted in 1991 on twelve single cells and eight 3- to 360-cell modules that encompass six battery technologies (Na/S, Li/MS, Ni/MH, Zn/Br, Ni/Fe, and Pb-Acid). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division. The results measure progress in battery R & D programs, compare battery technologies, and provide basic data for modeling and continuing R & D to battery users, developers, and program managers.

  7. 14 CFR 23.1585 - Operating procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... multiengine airplanes, information identifying each operating condition in which the fuel system independence... fuel system in a configuration used to show compliance with that section. (h) For each airplane showing compliance with § 23.1353 (g)(2) or (g)(3), the operating procedures for disconnecting the battery from its...

  8. Between-Day Reliability and Usefulness of a Fitness Testing Battery in Youth Sport Athletes: Reference Data for Practitioners

    ERIC Educational Resources Information Center

    Sawczuk, Thomas; Jones, Ben; Scantlebury, Sean; Weakley, Jonathan; Read, Dale; Costello, Nessan; Darrall-Jones, Joshua David; Stokes, Keith; Till, Kevin

    2018-01-01

    This study aimed to evaluate the between-day reliability and usefulness of a fitness testing battery in a group of youth sport athletes. Fifty-nine youth sport athletes (age = 17.3 ± 0.7 years) undertook a fitness testing battery including the isometric mid-thigh pull, counter-movement jump, 5-40 m sprint splits, and the 5-0-5 change of direction…

  9. 30 CFR 7.42 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.42 Definitions. The following definitions apply in this subpart: Battery assembly. A unit or units consisting of cells and their electrical connections, assembled in a battery box or boxes with covers. Battery box. The exterior sides, bottom, and...

  10. 30 CFR 7.42 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.42 Definitions. The following definitions apply in this subpart: Battery assembly. A unit or units consisting of cells and their electrical connections, assembled in a battery box or boxes with covers. Battery box. The exterior sides, bottom, and...

  11. 30 CFR 7.42 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.42 Definitions. The following definitions apply in this subpart: Battery assembly. A unit or units consisting of cells and their electrical connections, assembled in a battery box or boxes with covers. Battery box. The exterior sides, bottom, and...

  12. Battery life test using reconditioning

    NASA Technical Reports Server (NTRS)

    Sparks, R. H.

    1977-01-01

    A discussion is presented on nickel cadmium battery life tests using reconditioning and some comparative tests not using reconditioning. The discussion is aimed at the program application part of the testing. The goals of the program were to get an increased utilization out of the battery system in geosynchronous orbit. An attempt was made to push the depth of discharge operation up around 80 to 85 percent and the intent with the reconditioning program was to extend this type of utilization out towards a 10-year life and attune the voltage regulation.

  13. Strain measurement based battery testing

    DOEpatents

    Xu, Jeff Qiang; Steiber, Joe; Wall, Craig M.; Smith, Robert; Ng, Cheuk

    2017-05-23

    A method and system for strain-based estimation of the state of health of a battery, from an initial state to an aged state, is provided. A strain gauge is applied to the battery. A first strain measurement is performed on the battery, using the strain gauge, at a selected charge capacity of the battery and at the initial state of the battery. A second strain measurement is performed on the battery, using the strain gauge, at the selected charge capacity of the battery and at the aged state of the battery. The capacity degradation of the battery is estimated as the difference between the first and second strain measurements divided by the first strain measurement.

  14. A pilot evaluation of a computer-based psychometric test battery designed to detect impairment in patients with cirrhosis.

    PubMed

    Cook, Nicola A; Kim, Jin Un; Pasha, Yasmin; Crossey, Mary Me; Schembri, Adrian J; Harel, Brian T; Kimhofer, Torben; Taylor-Robinson, Simon D

    2017-01-01

    Psychometric testing is used to identify patients with cirrhosis who have developed hepatic encephalopathy (HE). Most batteries consist of a series of paper-and-pencil tests, which are cumbersome for most clinicians. A modern, easy-to-use, computer-based battery would be a helpful clinical tool, given that in its minimal form, HE has an impact on both patients' quality of life and the ability to drive and operate machinery (with societal consequences). We compared the Cogstate™ computer battery testing with the Psychometric Hepatic Encephalopathy Score (PHES) tests, with a view to simplify the diagnosis. This was a prospective study of 27 patients with histologically proven cirrhosis. An analysis of psychometric testing was performed using accuracy of task performance and speed of completion as primary variables to create a correlation matrix. A stepwise linear regression analysis was performed with backward elimination, using analysis of variance. Strong correlations were found between the international shopping list, international shopping list delayed recall of Cogstate and the PHES digit symbol test. The Shopping List Tasks were the only tasks that consistently had P values of <0.05 in the linear regression analysis. Subtests of the Cogstate battery correlated very strongly with the digit symbol component of PHES in discriminating severity of HE. These findings would indicate that components of the current PHES battery with the international shopping list tasks of Cogstate would be discriminant and have the potential to be used easily in clinical practice.

  15. The Testing Phase for the Small Unit Decision Making (SUDM) Assessment Battery

    DTIC Science & Technology

    2014-07-28

    on findings from the testing phase, several changes are recommended for the battery. First, it is recommended that self -report measures be separated...of a decision-making assessment battery. The five cognitive competencies are sensemaking, problem solving, adaptability, metacognition , and...flexibility, ambiguity tolerance, resilience, self -regulation, and self - awareness. We added the overarching construct of decision making and developed

  16. High discharge rate characteristics of nickel-cadmium batteries for pulse load filtering

    NASA Technical Reports Server (NTRS)

    Gearing, G. M.; Cimino, M. B.; Fritts, D. H.; Leonard, J. F.; Terzuoli, A. J., Jr.

    1985-01-01

    Several tests of specially fabricated nickel-cadmium batteries having circular disk type electrodes were considered. These batteries were evaluated as filter elements between a constant current power supply and a five hertz pulsed load demanding approximately twice the power supply current during the load on portion of the cycle. Short tests lasting 10,000 cycles were conducted at up to a 21 C rate and an equivalent energy density of over 40 Joules per pound. In addition, two batteries were subjected to 10 to the 7 charge/discharge cycles, one at a 6.5 C rate and the other at a 13 C rate. Assuming an electrode to battery weight ratio of 0.5, these tests represent an energy density of about 7 and 14 Joules per pound respectively. Energy density, efficiency, capacitance, average voltage, and available capacity were tracked during these tests. After 10 to the 7 cycles, capacity degradation was negligible for one battery and about 20% for the other. Cadmium electrode failure may be the factor limiting lifetime at extremely low depth of discharge cycling. The output was examined and a simple equivalent circuit was proposed.

  17. Lead oxide as used in lead acid storage batteries, part two

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orsino, J.A.

    1986-06-01

    Without oxide controls, the battery manufacturing business can become one of the most confusing and frustrating experiences known. Inexplicable things happen during mixing, pasting and assembly, and testing, in the laboratory or in the field becomes an unhappy event. Almost any oxide of sufficient purity can be processed to make a good battery, but the characteristics must be known to be able to process it right, and once the process has been established, the oxide must be uniformly made to make the resulting batteries uniformly good. Fortunately, the tests required to assure uniformity are few, and simple to perform. Assumingmore » pure pig lead from primary sources or from carefully refined secondary sources, three tests can tell the whole story. These tests are described.« less

  18. 10 CFR 429.39 - Battery chargers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Battery chargers. 429.39 Section 429.39 Energy DEPARTMENT... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.39 Battery chargers. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to battery chargers; and (2...

  19. 10 CFR 429.39 - Battery chargers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Battery chargers. 429.39 Section 429.39 Energy DEPARTMENT... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.39 Battery chargers. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to battery chargers; and (2...

  20. 10 CFR 429.39 - Battery chargers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Battery chargers. 429.39 Section 429.39 Energy DEPARTMENT... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.39 Battery chargers. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to battery chargers; and (2...

  1. Hubble Space Telescope electrical power system

    NASA Technical Reports Server (NTRS)

    Whitt, Thomas H.; Bush, John R., Jr.

    1990-01-01

    The Hubble Space Telescope (HST) electrical power system (EPS) is supplying between 2000 and 2400 W of continuous power to the electrical loads. The major components of the EPS are the 5000-W back surface field reflector solar array, the six nickel-hydrogen (NiH2) 22-cell 88-Ah batteries, and the charge current controllers, which, in conjunction with the flight computer, control battery charging. The operation of the HST EPS and the results of the HST NiH2 six-battery test are discussed, and preliminary flight data are reviewed. The HST NiH2 six-battery test is a breadboard of the HST EPS on test at Marshall Space Flight Center.

  2. Performance of alkaline battery cells used in emergency locator transmitters

    NASA Technical Reports Server (NTRS)

    Haynes, G. A.; Sokol, S.; Motley, W. R., III; Mcclelland, E. L.

    1984-01-01

    The characteristics of battery power supplies for emergency locator transmitters (ELT's) were investigated by testing alkaline zinc/manganese dioxide cells of the type typically used in ELT's. Cells from four manufacturers were tested. The cells were subjected to simulated environmental and load conditions representative of those required for survival and operation. Battery cell characteristics that may contribute to ELT malfunctions and limitations were evaluated. Experimental results from the battery cell study are discussed, and an evaluation of ELT performance while operating under a representative worst-case environmental condition is presented.

  3. Long life communication satellites: Electric power supply during the eclipse period

    NASA Technical Reports Server (NTRS)

    Font, S.

    1983-01-01

    The electric batteries, essentially nickel-cadmium for French satellites such as D1 A, D1 C, D1 D, D2 B, D5 A, D5 B, etc. and the batteries for such satellites as Symphonie, ANS, INTASAT, ESRO 4, and COS-B are discussed. The experience obtained led to the development of long lifetime batteries for communication satellites. Real simulation tests showed a lifetime of four years and accelerated lifetime tests of twelve years. These batteries will be applied in OTS, METEOSAT, and Marots. At the same time, new batteries are being developed, based on nickel-hydrogen or on silver-hydrogen, which should provide longer lifetime and better reliability.

  4. Battery charge control with temperature compensated voltage limit

    NASA Technical Reports Server (NTRS)

    Thierfelder, H. E.

    1983-01-01

    Battery charge control for orbiting spacecraft with mission durations from three to ten years, is a critical design feature that is discussed. Starting in 1974, the General Electric Space Systems Division designed, manufactured and tested battery systems for six different space programs. Three of these are geosynchronous missions, two are medium altitude missions and one is a near-earth mission. All six power subsystems contain nickel cadmium batteries which are charged using a temperature compensated voltage limit. This charging method was found to be successful in extending the life of nickel cadmium batteries in all three types of earth orbits. Test data and flight data are presented for each type of orbit.

  5. Results of chopper-controlled discharge life cycling studies on lead acid batteries

    NASA Technical Reports Server (NTRS)

    Ewashinka, J. G.; Sidik, S. M.

    1982-01-01

    A group of 108 state of the art nominally 6 volt lead acid batteries were tested in a program of one charge/discharge cycle per day for over two years or to ultimate battery failure. The primary objective was to determine battery cycle life as a function of depth of discharge (25 to 75 percent), chopper frequency (100 to 1000 Hz), duty cycle (25 to 87.5 percent), and average discharge current (20 to 260 A). The secondary objective was to determine the types of battery failure modes, if any, were due to the above parameters. The four parameters above were incorporated in a statistically designed test program.

  6. The USAF Phillips Laboratory sodium-sulfur battery technology program: Results and status

    NASA Technical Reports Server (NTRS)

    Rainbow, Marc E.; Somerville, Andrew

    1996-01-01

    Tests performed on NaS batteries are reported. The results of safety and abuse testing, shock and vibration tests, cell failure on warm-up, freeze thaw, overtemperature conditions, electrolyte fracture, overdischarge, and short circuit tests are presented along with GEO and LEO cycle tests and the status of the NaS cell flight tests.

  7. A Battery Test to Evaluate Life-Time Physical Fitness With Same Test Items.

    ERIC Educational Resources Information Center

    Meshizuka, Tetsuo

    A combination of physical fitness tests designed to be administered to a wide spectrum of the population, male and female, children and adults, is described. Three tests are included in this battery--motor fitness, physical fitness, and sports fitness. The philosophy behind this test structure is that motor fitness tests only measure and indicate…

  8. The effect of human immunodeficiency virus type 1 antibody status on military applicant aptitude test scores.

    PubMed

    Arday, D R; Brundage, J F; Gardner, L I; Goldenbaum, M; Wann, F; Wright, S

    1991-06-15

    The authors conducted a population-based study to attempt to estimate the effect of human immunodeficiency virus type 1 (HIV-1) seropositivity on Armed Services Vocational Aptitude Battery test scores in otherwise healthy individuals with early HIV-1 infection. The Armed Services Vocational Aptitude Battery is a 10-test written multiple aptitude battery administered to all civilian applicants for military enlistment prior to serologic screening for HIV-1 antibodies. A total of 975,489 induction testing records containing both Armed Services Vocational Aptitude Battery and HIV-1 results from October 1985 through March 1987 were examined. An analysis data set (n = 7,698) was constructed by choosing five controls for each of the 1,283 HIV-1-positive cases, matched on five-digit ZIP code, and a multiple linear regression analysis was performed to control for demographic and other factors that might influence test scores. Years of education was the strongest predictor of test scores, raising an applicant's score on a composite test nearly 0.16 standard deviation per year. The HIV-1-positive effect on the composite score was -0.09 standard deviation (99% confidence interval -0.17 to -0.02). Separate regressions on each component test within the battery showed HIV-1 effects between -0.39 and +0.06 standard deviation. The two Armed Services Vocational Aptitude Battery component tests felt a priori to be the most sensitive to HIV-1-positive status showed the least decrease with seropositivity. Much of the variability in test scores was not predicted by either HIV-1 serostatus or the demographic and other factors included in the model. There appeared to be little evidence of a strong HIV-1 effect.

  9. 30 CFR 7.45 - Critical characteristics

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.45 Critical characteristics The following critical characteristics shall be inspected or tested on each battery assembly to...

  10. 30 CFR 7.45 - Critical characteristics

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.45 Critical characteristics The following critical characteristics shall be inspected or tested on each battery assembly to...

  11. 30 CFR 18.68 - Tests for intrinsic safety.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... normal use. (iii) Semiconductors shall be amply sized. Rectifiers and transistors shall be operated at... battery, or installed as close to the battery terminal as practicable. (3) Transistors of battery-operated...

  12. Adiabatic charging of nickel-hydrogen batteries

    NASA Technical Reports Server (NTRS)

    Lurie, Chuck; Foroozan, S.; Brewer, Jeff; Jackson, Lorna

    1995-01-01

    Battery management during prelaunch activities has always required special attention and careful planning. The transition from nickel-cadium to nickel-hydrogen batteries, with their high self discharge rate and lower charge efficiency, as well as longer prelaunch scenarios, has made this aspect of spacecraft battery management even more challenging. The AXAF-I Program requires high battery state of charge at launch. The use of active cooling, to ensure efficient charging, was considered and proved to be difficult and expensive. Alternative approaches were evaluated. Optimized charging, in the absence of cooling, appeared promising and was investigated. Initial testing was conducted to demonstrate the feasibility of the 'Adiabatic Charging' approach. Feasibility was demonstrated and additional testing performed to provide a quantitative, parametric data base. The assumption that the battery is in an adiabatic environment during prelaunch charging is a conservative approximation because the battery will transfer some heat to its surroundings by convective air cooling. The amount is small compared to the heat dissipated during battery overcharge. Because the battery has a large thermal mass, substantial overcharge can occur before the cells get too hot to charge efficiently. The testing presented here simulates a true adiabatic environment. Accordingly the data base may be slightly conservative. The adiabatic charge methodology used in this investigation begins with stabilizing the cell at a given starting temperature. The cell is then fully insulated on all sides. Battery temperature is carefully monitored and the charge terminated when the cell temperature reaches 85 F. Charging has been evaluated with starting temperatures from 55 to 75 F.

  13. Individual differences in false memory from misinformation: cognitive factors.

    PubMed

    Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; Lin, Chongde; He, Qinghua; Chen, Chunhui; Li, He; Xue, Gui; Lu, Zhonglin; Dong, Qi

    2010-07-01

    This research investigated the cognitive correlates of false memories that are induced by the misinformation paradigm. A large sample of Chinese college students (N=436) participated in a misinformation procedure and also took a battery of cognitive tests. Results revealed sizable and systematic individual differences in false memory arising from exposure to misinformation. False memories were significantly and negatively correlated with measures of intelligence (measured with Raven's Advanced Progressive Matrices and Wechsler Adult Intelligence Scale), perception (Motor-Free Visual Perception Test, Change Blindness, and Tone Discrimination), memory (Wechsler Memory Scales and 2-back Working Memory tasks), and face judgement (Face Recognition and Facial Expression Recognition). These findings suggest that people with relatively low intelligence and poor perceptual abilities might be more susceptible to the misinformation effect.

  14. A Brief Review of Handgrip Strength and Sport Performance.

    PubMed

    Cronin, John; Lawton, Trent; Harris, Nigel; Kilding, Andrew; McMaster, Daniel T

    2017-11-01

    Cronin, J, Lawton, T, Harris, N, Kilding, A, and McMaster, DT. A brief review of handgrip strength and sport performance. J Strength Cond Res 31(11): 3187-3217, 2017-Tests of handgrip strength (HGS) and handgrip force (HGF) are commonly used across a number of sporting populations. Measures of HGS and HGF have also been used by practitioners and researchers to evaluate links with sports performance. This article first evaluates the validity and reliability of various handgrip dynamometers (HGD) and HGF sensors, providing recommendations for procedures to ensure that precise and reliable data are collected as part of an athlete's testing battery. Second, the differences in HGS between elite and subelite athletes and the relationships between HGS, HGF, and sports performance are discussed.

  15. 14 CFR 29.1585 - Operating procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... condition in which the fuel system independence prescribed in § 29.953 is necessary for safety must be furnished, together with instructions for placing the fuel system in a configuration used to show compliance... compliance with § 29.1353 (c)(6)(ii) or (c)(6)(iii), the operating procedures for disconnecting the battery...

  16. Baseline tests of the EPC Hummingbird electric passenger vehicle

    NASA Technical Reports Server (NTRS)

    Slavik, R. J.; Maslowski, E. A.; Sargent, N. B.; Birchenough, A. G.

    1977-01-01

    The rear-mounted internal combustion engine in a four-passenger Volkswagen Thing was replaced with an electric motor made by modifying an aircraft generator and powered by 12 heavy-duty, lead-acid battery modules. Vehicle performance tests were conducted to measure vehicle maximum speed, range at constant speed, range over stop-and-go driving schedules, maximum acceleration, gradeability limit, road energy consumption, road power, indicated energy consumption, braking capability, battery charger efficiency, and battery characteristics. Test results are presented in tables and charts.

  17. Development and Field Test of the Trial Battery for Project A. Improving the Selection, Classification and Utilization of Army Enlisted Personnel. Project A: Improving the Selection, Classification and Utilization of Army Enlisted Personnel. ARI Technical Report 739.

    ERIC Educational Resources Information Center

    Peterson, Norman G., Ed.

    As part of the United States Army's Project A, research has been conducted to develop and field test a battery of experimental tests to complement the Armed Services Vocational Aptitude Battery in predicting soldiers' job performance. Project A is the United States Army's large-scale manpower effort to improve selection, classification, and…

  18. Development and testing of a high cycle life 30 A-h sealed AgO-Zn battery

    NASA Technical Reports Server (NTRS)

    Bogner, R. S.

    1972-01-01

    A two-phase program was initiated to investigate design parameters and technology to develop an improved AgO-Zn battery. The basic performance goal was 100 charge/discharge cycles (22 h/2 h) at 50 percent depth of discharge following a six-month period of charged stand at room temperature. Phase 1, cell evaluation, involved testing 70 cells in five-cell groups. The major design variables were active material ratios, electrolyte concentrations, separator systems, and negative plate shape. Phase 1 testing showed that cycle life could be improved 10 percent to 20 percent by using greater ratios of zinc to silver oxide and higher electrolyte concentrations. Wedge-shaped negatives increased cycle life by nearly 100 percent. Phase 2 battery evaluation, which was initiated before the Phase 1 results were known completely, involved evaluation of six designs as 19-cell batteries. Only one battery exceeded 100 cycles following nine months charged stand.

  19. Sodium sulfur electric vehicle battery engineering program final report, September 2, 1986--June 15, 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1993-06-01

    In September 1986 a contract was signed between Chloride Silent Power Limited (CSPL) and Sandia National Laboratories (SNL) entitled ``Sodium Sulfur Electric Vehicle Battery Engineering Program``. The aim of the cost shared program was to advance the state of the art of sodium sulfur batteries for electric vehicle propulsion. Initially, the work statement was non-specific in regard to the vehicle to be used as the design and test platform. Under a separate contract with the DOE, Ford Motor Company was designing an advanced electric vehicle drive system. This program, called the ETX II, used a modified Aerostar van for itsmore » platform. In 1987, the ETX II vehicle was adopted for the purposes of this contract. This report details the development and testing of a series of battery designs and concepts which led to the testing, in the US, of three substantial battery deliverables.« less

  20. Engineering and Abuse Testing of Panasonic Lithium-Ion Battery and Cells

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.; Bragg, Bobby J.

    2000-01-01

    This viewgraph presentation reviews the performance testing of Lithium Ion batteries and cells under different conditions of charge and discharge. The tests show that the 0.5 C rate of charge and discharge might be the ideal condition for long term cycling. It reviews the issues of overcharge and overdischarge of the cells. The cells and the battery have adequate protection under both conditions to prevent any catastrophic occurrences. Temperatures above 150 C are required to vent the cells or cause a thermal runaway, Since this situation is non-credible in the cabin of the Space Shuffle or ISS this should not pose a problem. The presentation includes graphs and charts showing the charge and discharge capacities of the battery and also the current and voltage profiles. A view of a circuit board which contains the controlling mechanism for the battery is also shown.

  1. The re-emergence of sodium ion batteries: testing, processing, and manufacturability

    PubMed Central

    Roberts, Samuel; Kendrick, Emma

    2018-01-01

    With the re-emergence of sodium ion batteries (NIBs), we discuss the reasons for the recent interests in this technology and discuss the synergies between lithium ion battery (LIB) and NIB technologies and the potential for NIB as a “drop-in” technology for LIB manufacturing. The electrochemical testing of sodium materials in sodium metal anode arrangements is reviewed. The performance, stability, and polarization of the sodium in these test cells lead to alternative testing in three-electrode and alternative anode cell configurations. NIB manufacturability is also discussed, together with the impact that the material stability has upon the electrodes and coating. Finally, full-cell NIB technologies are reviewed, and literature proof-of-concept cells give an idea of some of the key differences in the testing protocols of these batteries. For more commercially relevant formats, safety, passive voltage control through cell balancing and cell formation aspects are discussed. PMID:29910609

  2. Metal sulfide for battery applications

    NASA Astrophysics Data System (ADS)

    Guidotti, Ronald A.

    1988-08-01

    A number of metal sulfides can be used in batteries as a cathode (reducible) material as part of an electrochemical couple to provide energy. There are a number of physical and chemical characteristics that can be evaluated for screening potential candidates for use in batteries. These include: cell potential vs. Li, thermal and chemical stability, electrical conductivity, allotropic form (phase), reaction kinetics during discharge, type of discharge mechanism, and material rechargeability. These are reviewed in general, with emphasis on sulfides of copper, iron, and molybdenum which are currently being used as cathodes in Li and Li-alloy batteries. The presence of impurities can adversely impact performance when naturally occurring sulfide minerals are used for battery applications. Sandia National Laboratories uses natural pyrite (FeS2) for its high-temperature, thermally activated Li(Si)/FeS2 batteries. The purification and processing procedures for the FeS2 involves both chemical and physical methods. Flotation was found to yield comparable results as HF leaching for removal of silica, but without the negative health and environmental concerns associated with this technique.

  3. NASA Battery Working Group - 2007-2008: Battery Task Summary Report

    NASA Technical Reports Server (NTRS)

    Manzo, Michelle

    2008-01-01

    This presentation provides a summary of the 2007-2008 NASA Battery Working Group efforts completed in support of the NASA Engineering Safety Center (NESC). The effort covered a series of pro-active tasks that address the following: Binding Procurements -- guidelines related to requirements for the battery system that should be considered at the time of contract award Wet Life of Ni-H2 Batteries -- issues/strategies for effective storage and impact of long-term storage on performance and life Generic Guidelines for Lithium-ion Safety, Handling and Qualification -- Standardized approaches developed and risk assessments (1) Lithium-ion Performance Assessment -- survey of manufacturers and capabilities to meet mission needs. Guidelines document generated (2) Conditions Required for using Pouch Cells in Aerospace Missions -- focus on corrosion, thermal excursions and long-term performance issues. Document defining requirements to maintain performance and life (3) High Voltage Risk Assessment -- focus on safety and abuse tolerance of battery module assemblies. Recommendations of features required for safe implementation (4) Procedure for Determination of Safe Charge Rates -- evaluation of various cell chemistries and recommendation of safe operating regimes for specific cell designs

  4. Test accommodations for individuals with neurological conditions completing the NIH Toolbox-Cognition Battery: An evaluation of frequency and appropriateness.

    PubMed

    Magasi, Susan; Harniss, Mark; Tulsky, David S; Cohen, Matthew L; Heaton, Robert K; Heinemann, Allen W

    2017-11-01

    First, to evaluate the frequency with which individuals with neurological conditions require test administration accommodations for the NIH Toolbox-Cognition Battery (NIHTB-CB). Second, to evaluate the appropriateness of accommodations provided by administrators, including adherence to NIHTB-CB Reasonable Accommodations Guidelines. Adults with traumatic brain injury, spinal cord injury, or stroke (n = 604) completed the NIHTB-CB and other assessments as part of a multisite study. We provide a descriptive, secondary analysis of test administrator notes to determine use and appropriateness of accommodations. Of the 604 participants, 450 (75%) completed the NIHTB-CB using standard administration procedures, but 137 (22.6%) encountered accessibility challenges that required accommodations. Participants with motor function impairments were most likely to receive at least 1 of 3 kinds of accommodations: (a) use of nonstandard methods of entering responses using standard input devices, (b) use of alternate input devices, or (c) help from the test administrator to enter a response. Fatigue and/or impulsivity led to nonstandard administration by 48 (7.9%) individuals. Post hoc audit of test administrator notes revealed that despite careful instructions and supervision, 49 (56.3%) of the accommodated administrations breached standardization and scores could not be interpreted using test norms. Although the NIHTB-CB was developed for individuals without neurological impairment, most individuals with neurological conditions completed the standardized administration without accommodations. When accommodations were needed, administrators did not adhere to the official Reasonable Accommodations Guidelines in more than half of the cases. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. Molindone: effects in pigeons responding under conditional discrimination tasks.

    PubMed

    Picker, M J; Cleary, J P; Berens, K; Oliveto, A H; Dykstra, L A

    1989-02-01

    Pigeons were trained to respond under three conditional discrimination procedures; 1) a fixed-consecutive-number procedure with (FCN 8-SD) and without (FCN 8) an added external discriminative stimulus, 2) a delayed matching-to-sample (DMTS) procedure using 0-sec, 2-sec and 8-sec delay intervals, and 3) a repeated acquisition of behavioral chains (RA) procedure using a four-link response chain with three stimulus keys. The atypical neuroleptic agent molindone decreased accuracy under the FCN 8 at doses that had no effect on accuracy under the FCN 8-SD. Under the DMTS procedure, molindone-induced decreases in accuracy were directly related to the delay interval, with the largest relative decrements obtained at the 8-sec delay and the smallest at the 0-sec delay. Under the RA procedure, molindone decreased accuracy at doses that had little or no effect on the number of correct responses emitted. Relative to control values, molindone-induced decreases in accuracy were smallest under the DMTS and FCN 8-SD procedures and largest under the FCN 8 and RA procedures. The differential effects obtained with molindone under each of these procedures illustrate the need to employ a variety of assays when determining the behavioral actions of neuroleptics. In addition, this battery of behavioral tests may provide a useful tool for assessing the different neurochemical actions of neuroleptic compounds.

  6. Microbatteries for Combinatorial Studies of Conventional Lithium-Ion Batteries

    NASA Technical Reports Server (NTRS)

    West, William; Whitacre, Jay; Bugga, Ratnakumar

    2003-01-01

    Integrated arrays of microscopic solid-state batteries have been demonstrated in a continuing effort to develop microscopic sources of power and of voltage reference circuits to be incorporated into low-power integrated circuits. Perhaps even more importantly, arrays of microscopic batteries can be fabricated and tested in combinatorial experiments directed toward optimization and discovery of battery materials. The value of the combinatorial approach to optimization and discovery has been proven in the optoelectronic, pharmaceutical, and bioengineering industries. Depending on the specific application, the combinatorial approach can involve the investigation of hundreds or even thousands of different combinations; hence, it is time-consuming and expensive to attempt to implement the combinatorial approach by building and testing full-size, discrete cells and batteries. The conception of microbattery arrays makes it practical to bring the advantages of the combinatorial approach to the development of batteries.

  7. EMU Battery/module Service Tool Characterization Study

    NASA Technical Reports Server (NTRS)

    Palandati, C. F.

    1984-01-01

    The power tool which will be used to replace the attitude control system in the SMM spacecraft is being modified to operate from a self contained battery. The extravehicular mobility unit (EMU) battery, a silver zinc battery, was tested for the power tool application. The results obtained during show the EMU battery is capable of operating the power tool within the pulse current range of 2.0 to 15.0 amperes and battery temperature range of -10 to 40 degrees Celsius.

  8. Woodcock-Johnson-III, Kaufman Adolescent and Adult Intelligence Test (KAIT), Kaufman Assessment Battery for Children (KABC), and Differential Ability Scales (DAS) support Carroll but not Cattell-Horn.

    PubMed

    Cucina, Jeffrey M; Howardson, Garett N

    2017-08-01

    Recently emerging evidence suggests that the dominant structural model of mental abilities-the Cattell-Horn-Carroll (CHC) model-may not adequately account for observed scores for mental abilities batteries, leading scholars to call into question the model's validity. Establishing the robustness of these findings is important since CHC is the foundation for several contemporary mental abilities test batteries, such as the Woodcock-Johnson III (WJ-III). Using confirmatory factor analysis, we investigated CHC's robustness across 4 archival samples of mental abilities test battery data, including the WJ-III, the Kaufman Adolescent & Adult Intelligence Test (KAIT), the Kaufman Assessment Battery for Children (KABC), and the Differential Ability Scales (DAS). We computed omega hierarchical (ωH) and omega subscale (ωS) coefficients for g and the broad factors, which estimated the relationship of composite scores to g and the broad factors, respectively. Across all 4 samples, we found strong evidence for a general ability, g. We additionally found evidence for 3 to 9 residualized, orthogonal broad abilities existing independently of g, many of which also explained reliable variance in test battery scores that cannot be accounted for by g alone. The reliabilities of these broad factors, however, were less than desirable (i.e., <.80) and achieving desirable reliabilities would be practically infeasible (e.g., requiring excessively large numbers of subtests). Our results, and those of CHC critics, are wholly consistent with Carroll's model. Essentially, both g and orthogonal broad abilities are required to explain variance in mental abilities test battery scores, which is consistent with Carroll but not Cattell-Horn. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. Diagnostic hearing testing of infants aged 0-36 months in 3 South African provinces - Comparison of audiology records to HPCSA guidelines.

    PubMed

    Moodley, Selvarani; Störbeck, Claudine

    2016-12-01

    Within the Early Hearing Detection and Intervention (EHDI) pathway, which includes the processes of screening, diagnosis and intervention for paediatric hearing loss, paediatric diagnostic audiology involves a battery of specific tests and procedures. International studies have highlighted a golden standard for diagnosis of paediatric hearing loss as based on the Joint Committee of Infant Hearing (2007) diagnostic guidelines, closely resembling the HPCSA diagnostic guidelines. There are limited South African studies on the processes and protocols followed in diagnostic paediatric audiology. This study aims to provide a comparison for how the tests used for diagnosis of paediatric hearing loss in South Africa (within both the public and private healthcare sectors) compare to the HPCSA recommended diagnostic guidelines. A retrospective record review of paediatric clients with hearing loss (recruited through nonprobability convenience sampling) was conducted. This study is part of a longitudinal study of 711 deaf or hard of hearing children referred to the HI HOPES early intervention programme from September 2006 to December 2011. Diagnostic data from audiology reports of 117 children between 0 and 36 months were coded and analysed. Large variation was found in the tests included in the diagnostic audiology reports. For 22 children (19%) a comprehensive test battery was used. Health Professions Council of South Africa (HPCSA) recommended guidelines for diagnostic testing were not followed in any of the records analysed. Components of the HPCSA recommended test battery most frequently omitted was bone conduction testing. For both electrophysiology and behavioural testing, there was limited frequency specificity information. This exclusion of information is evidence of deficiencies in data recording and management, as well as having an effect on accuracy of classification of degree and type of hearing loss. There are gaps in age-appropriate assessment protocols, which will have an effect on accurate differential diagnosis of paediatric hearing loss. Reasons for not including all testing components of the HPCSA recommended guidelines, as well as the possibility of developing guidelines more relevant to a developing world context, should be explored. There might be a need for. The impact of South African specific factors that have an effect on provision of accurate paediatric diagnostic audiology services should be determined. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Development of automotive battery systems capable of surviving modern underhood environments

    NASA Astrophysics Data System (ADS)

    Pierson, John R.; Johnson, Richard T.

    The starting, lighting, and ignition (SLI) battery in today's automobile typically finds itself in an engine compartment that is jammed with mechanical, electrical, and electronic devices. The spacing of these devices precludes air movement and, thus, heat transfer out of the compartment. Furthermore, many of the devices, in addition to the internal combustion engine, actually generate heat. The resulting underhood environment is extremely hostile to thermally-sensitive components, especially the battery. All indications point to a continuation of this trend towards higher engine-compartment temperatures as future vehicles evolve. The impact of ambient temperature on battery life is clearly demonstrated in the failure-mode analysis conducted by the Battery Council International in 1990. This study, when combined with additional failure-mode analyses, vehicle systems simulation, and elevated temperature life testing, provides insight into the potential for extension of life of batteries. Controlled fleet and field tests are used to document and quantify improvements in product design. Three approaches to battery life extension under adverse thermal conditions are assessed, namely: (i) battery design; (ii) thermal management, and (iii) alternative battery locations. The advantages and disadvantages of these approaches (both individually and in combination) for original equipment and aftermarket applications are explored.

  11. Use of COTS Batteries on ISS and Shuttle: Payload Safety and Mission Success

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.

    2004-01-01

    Contents: Current program requirements; Challenges with COTS batteries; manned vehicle COTS methodology in use; List of typical flight COTS batteries; Energy content and toxicity; Hazards, failure modes and controls for different battery chemistries; JSC test details; List of incidents from Consumer Protection Safety Commission; Conclusions ans recommendations.

  12. Lithium-Ion Battery Demonstrated for NASA Desert Research and Technology Studies

    NASA Technical Reports Server (NTRS)

    Bennett, William R.; Baldwin, Richard S.

    2008-01-01

    Lithium-ion batteries have attractive performance characteristics that are well suited to a number of NASA applications. These rechargeable batteries produce compact, lightweight energy-storage systems with excellent cycle life, high charge/discharge efficiency, and low self-discharge rate. NASA Glenn Research Center's Electrochemistry Branch designed and produced five lithium-ion battery packs configured to power the liquid-air backpack (LAB) on spacesuit simulators. The demonstration batteries incorporated advanced, NASA-developed electrolytes with enhanced low-temperature performance characteristics. The objectives of this effort were to (1) demonstrate practical battery performance under field-test conditions and (2) supply laboratory performance data under controlled laboratory conditions. Advanced electrolyte development is being conducted under the Exploration Technology Development Program by the NASA Jet Propulsion Laboratory. Three field trials were successfully completed at Cinder Lake from September 10 to 12, 2007. Extravehicular activities of up to 1 hr and 50 min were supported, with residual battery capacity sufficient for 30 min of additional run time. Additional laboratory testing of batteries and cells is underway at Glenn s Electrochemical Branch.

  13. A statistically compiled test battery for feasible evaluation of knee function after rupture of the Anterior Cruciate Ligament - derived from long-term follow-up data.

    PubMed

    Schelin, Lina; Tengman, Eva; Ryden, Patrik; Häger, Charlotte

    2017-01-01

    Clinical test batteries for evaluation of knee function after injury to the Anterior Cruciate Ligament (ACL) should be valid and feasible, while reliably capturing the outcome of rehabilitation. There is currently a lack of consensus as to which of the many available assessment tools for knee function that should be included. The present aim was to use a statistical approach to investigate the contribution of frequently used tests to avoid redundancy, and filter them down to a proposed comprehensive and yet feasible test battery for long-term evaluation after ACL injury. In total 48 outcome variables related to knee function, all potentially relevant for a long-term follow-up, were included from a cross-sectional study where 70 ACL-injured (17-28 years post injury) individuals were compared to 33 controls. Cluster analysis and logistic regression were used to group variables and identify an optimal test battery, from which a summarized estimator of knee function representing various functional aspects was derived. As expected, several variables were strongly correlated, and the variables also fell into logical clusters with higher within-correlation (max ρ = 0.61) than between clusters (max ρ = 0.19). An extracted test battery with just four variables assessing one-leg balance, isokinetic knee extension strength and hop performance (one-leg hop, side hop) were mathematically combined to an estimator of knee function, which acceptably classified ACL-injured individuals and controls. This estimator, derived from objective measures, correlated significantly with self-reported function, e.g. Lysholm score (ρ = 0.66; p<0.001). The proposed test battery, based on a solid statistical approach, includes assessments which are all clinically feasible, while also covering complementary aspects of knee function. Similar test batteries could be determined for earlier phases of ACL rehabilitation or to enable longitudinal monitoring. Such developments, established on a well-grounded consensus of measurements, would facilitate comparisons of studies and enable evidence-based rehabilitation.

  14. A Comparison of Two Panasonic Lithium-Ion Batteries and Cells for the IBM Thinkpad

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.; Cook, Joseph S.; Davies, Francis J.; Collins, Jacob; Bragg, Bobby J.

    2003-01-01

    The IBM Thinkpad 760XD has been used in the Orbiter and International Space Station since 2000. The Thinkpad is powered by a Panasonic Li-ion battery that has a voltage of 10.8 V and 3.0 Ah capacity. This Thinkpad is now being replaced by the IBM Thinkpad A31P which has a Panasonic Li-ion battery that has a voltage of 10.8 V and 4.0 Ah capacity. Both batteries have protective circuit boards. The Panasonic battery for the Thinkpad 760XD had 12 Panasonic 17500 cells of 0.75 Ah capacity in a 4P3S cOnfiguration. The new Panasonic battery has 6 Panasonic 18650 cells of 2.0 Ah capacity in a 2P3S configuration. The batteries and cells for both models have been evaluated for performance and safety. A comparison of the cells under similar test conditions will be presented. The performance of the cells has been evaluated under different rates of charge and discharge and different temperatures. The cells have been tested under abuse conditions and the safety features in the cells evaluated. The protective circuit board in the battery was also tested under conditions of overcharge, overdischarge, short circuit and unbalanced cell configurations. The results of the studies will be presented in this paper.

  15. Early Education Screening Test Battery of Basic Skills Development: Criteria for Personalizing Programs.

    ERIC Educational Resources Information Center

    University City School District, MO.

    The development and content of the Early Education Screening Test Battery are described elsewhere (TM 000 184). This report provides norms for the Gross Motor Test (GMO), Visual-Motor Integration (VMI), four scales of the Illinois Test of Psycholinguistic Abilities (ITPA), Peabody Picture Vocabulary Test (PPVT), and the Behavior Rating Scale…

  16. Assessment of lnternational Space Station (ISS) Lithium-ion Battery Thermal Runaway (TR)

    NASA Technical Reports Server (NTRS)

    Graika, Jason

    2017-01-01

    This task was developed in the wake of the Boeing 787 Dreamliner lithium-ion battery TR incidents of January 2013 and January 2014. The Electrical Power Technical Discipline Team supported the Dreamliner investigations and has followed up by applying lessons learned to conduct an introspective evaluation of NASA's risk of similar incidents in its own lithium-ion battery deployments. This activity has demonstrated that historically NASA, like Boeing and others in the aerospace industry, has emphasized the prevention of TR in a single cell within the battery (e.g., cell screening) but has not considered TR severity-reducing measures in the event of a single-cell TR event. center dotIn the recent update of the battery safety standard (JSC 20793) to address this paradigm shift, the NASA community included requirements for assessing TR severity and identifying simple, low-cost severity reduction measures. This task will serve as a pathfinder for meeting those requirements and will specifically look at a number of different lithium-ion batteries currently in the design pipeline within the ISS Program batteries that, should they fail in a Dreamliner-like incident, could result in catastrophic consequences. This test is an abuse test to understand the heat transfer properties of the cell and ORU in thermal runaway, with radiant barriers in place in a flight like test in on orbit conditions. This includes studying the heat flow and distribution in the ORU. This data will be used to validate the thermal runaway analysis. This test does not cover the ambient pressure case. center dotThere is no pass/ fail criteria for this test.

  17. Lithium-Thionyl Chloride Batteries for the Mars Pathfinder Microrover

    NASA Technical Reports Server (NTRS)

    Deligiannis, Frank; Frank, Harvey; Staniewicz, R. J.; Willson, John

    1996-01-01

    A discussion of the power requirements for the Mars Pathfinder Mission is given. Topics include: battery requirements; cell design; battery design; test descriptions and results. A summary of the results is also included.

  18. Content Validity Index and Intra- and Inter-Rater Reliability of a New Muscle Strength/Endurance Test Battery for Swedish Soldiers

    PubMed Central

    Larsson, Helena; Tegern, Matthias; Monnier, Andreas; Skoglund, Jörgen; Helander, Charlotte; Persson, Emelie; Malm, Christer; Broman, Lisbet; Aasa, Ulrika

    2015-01-01

    The objective of this study was to examine the content validity of commonly used muscle performance tests in military personnel and to investigate the reliability of a proposed test battery. For the content validity investigation, thirty selected tests were those described in the literature and/or commonly used in the Nordic and North Atlantic Treaty Organization (NATO) countries. Nine selected experts rated, on a four-point Likert scale, the relevance of these tests in relation to five different work tasks: lifting, carrying equipment on the body or in the hands, climbing, and digging. Thereafter, a content validity index (CVI) was calculated for each work task. The result showed excellent CVI (≥0.78) for sixteen tests, which comprised of one or more of the military work tasks. Three of the tests; the functional lower-limb loading test (the Ranger test), dead-lift with kettlebells, and back extension, showed excellent content validity for four of the work tasks. For the development of a new muscle strength/endurance test battery, these three tests were further supplemented with two other tests, namely, the chins and side-bridge test. The inter-rater reliability was high (intraclass correlation coefficient, ICC2,1 0.99) for all five tests. The intra-rater reliability was good to high (ICC3,1 0.82–0.96) with an acceptable standard error of mean (SEM), except for the side-bridge test (SEM%>15). Thus, the final suggested test battery for a valid and reliable evaluation of soldiers’ muscle performance comprised the following four tests; the Ranger test, dead-lift with kettlebells, chins, and back extension test. The criterion-related validity of the test battery should be further evaluated for soldiers exposed to varying physical workload. PMID:26177030

  19. Modeling a constant power load for nickel-hydrogen battery testing using SPICE

    NASA Technical Reports Server (NTRS)

    Bearden, Douglas B.; Lollar, Louis F.; Nelms, R. M.

    1990-01-01

    The effort to design and model a constant power load for the HST (Hubble Space Telescope) nickel-hydrogen battery tests is described. The constant power load was designed for three different simulations on the batteries: life cycling, reconditioning, and capacity testing. A dc-dc boost converter was designed to act as this constant power load. A boost converter design was chosen because of the low test battery voltage (4 to 6 VDC) generated and the relatively high power requirement of 60 to 70 W. The SPICE model was shown to consistently predict variations in the actual circuit as various designs were attempted. It is concluded that the confidence established in the SPICE model of the constant power load ensures its extensive utilization in future efforts to improve performance in the actual load circuit.

  20. Improvement of bench life-tests for automotive batteries

    NASA Astrophysics Data System (ADS)

    Richter, G.

    A common method for rating the endurance of automotive batteries is the bench life-test according to DIN, IEC, SAE or JIS. With an increasing number of maintenance-free batteries on the market, the application of these tests becomes more problematic. This is due to a step-by-step capacity decline during cycling if the content of autimony in the grid-alloy is decreased. The degradation in performance is caused by the phenomenon of acid stratification. Because this debilitating effect occurs only rarely in service (vehicle movement) if charging and discharging is well balanced, there is a need for a new bench life-test with conditions that are more representative of practical conditions. Research has shown that the main changes should be: (i) an accelerated (moved) battery during cycling; (ii) slightly lower charging or discharging capacity amplitude, also with a lower mean value.